WorldWideScience

Sample records for ultrasound guided fine-needle

  1. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  2. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  3. Ultrasound guided percutaneous fine needle aspiration biopsy of the liver with focal lesion

    International Nuclear Information System (INIS)

    Ko, Gang Seok; Yang, Hyun Cheol; Park, Byoung Lan; Kim, Byoung Geun; Sohn, Jang Sihn

    1985-01-01

    The ultrasound-guided fine needle aspirations were performed in order to diagnose a suspected neoplastic or infectious disease in 52 patients with focal liver disease. Of these, neoplastic lesions were suspected in 31 patients and infectious lesions in 21 patients ultrasonically and/or clinically. The overall accuracy for both suspected malignant and infectious disease was 79% (41/52). The primary indication for fine needle aspiration was to document the presence of malignancy and to avoid a diagnostic laparotomy, and to drain hepatic abscess. Consequently we were convinced that the ultrasound-guided percutaneous fine needle aspiration biopsy in the focal liver disease is the best method for a conclusive diagnosis

  4. A comparison of ultrasound guided fine needle aspiration cytology and core needle biopsy in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Altaf, H.N.; Farooqui, F.

    2015-01-01

    Objective: To compare ultrasound guided fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients presenting with palpable breast lumps (PBLs), in terms of sensitivity and specificity, taking final histopathology as gold standard. Methodology: This cross-sectional study was conducted at Holy Family Hospital, Rawalpindi, Pakistan. Ultrasound guided FNAC and CNB were taken of all female patients with PBLs. The results were compared with final histopathology as gold standard. Data analysis was performed using SPSS software and chi-square test. Results: A total of 60 patients were included in the study. The mean age was 33.8 yrs. The sensitivity and specificity of ultrasound guided FNAC were 68.7% and 93.1%, respectively. The sensitivity and specificity of ultrasound guided CNB was 93.7% and 100%. The accuracy of FNAC was 86.2% and that of core needle biopsy was 98.3%. Conclusion: The ultrasound guided core needle biopsy can be used as an initial diagnostic test for the evaluation of all PBLs. Because of high negative predictive value core needle biopsy can replace surgical excision biopsy for benign lesions. (author)

  5. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  6. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Multiple Thyroid Nodules

    International Nuclear Information System (INIS)

    Kim, Ji Dae; Bae, Il Hun; Lee, Seung Young; Han, Gi Seok; Cha, Sang Hun; Kim, Sung Jin; Park, Kil Sun; Koong, Sung Soo; Lee, Ok Jun

    2006-01-01

    To standardize the number of nodules which necessitates ultrasound-guided, fine-needle, aspiration biopsy in patients who have multiple thyroid nodules with the same sonographic characteristics as each other. From February, 2002 to March, 2004, among patients whose diagnosis was confirmed by ultrasound-guided, fine-needle, aspiration biopsy, 545 nodules of 203 patients were found in sonography with more than two thyroid nodules. Each thyroid gland nodule was classified on a score from 0 to 2 points on the basis of the following 5 characteristics: internal content, margin, echogenicity, shape and calcification in sonography. When the score of all characteristics was the same, by deciding on nodules with the same sonographic characteristics and with the score of at least one characteristic being different, we divided the nodules with different sonographic characteristics in a patient. By methods such as given in the preceding descriptions, patients with multiple thyroid nodules were separated into two groups: one in which all nodules had the same sonographic characteristics and another in which nodules have at least one different sonographic characteristic. Then, each pathologic result was searched for the same case and different case in each patient group. Among the 203 patients who were diagnosed with multiple thyroid nodules in ultrasonography, 79 patients (38.9%) had nodules with the same ultrasonographic characteristics and 124 patients (61.1%) had nodules with at least one different ultrasonographic characteristic. All 79 patient's nodules with the same ultrasonographic characteristics in each patient showed the same pathologic result in all cases (100.0%) and there was no case showing a different pathologic result. Otherwise, among the 124 patient's nodules with different ultrasonographic characteristics, each patient showed the same pathologic result in 111 (89.5%) and different pathologic result in 13 (10.5%). In patients who have multiple thyroid nodules

  7. Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses.

    Science.gov (United States)

    Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed

    2013-10-01

    Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate.

  8. Ultrasound-guided fine needle aspiration in the diagnosis of peripheral nerve sheath tumors in 4 dogs

    Science.gov (United States)

    da Costa, Ronaldo C.; Parent, Joane M.; Dobson, Howard; Ruotsalo, Kristiina; Holmberg, David; Duque, M. Carolina; Poma, Roberto

    2008-01-01

    Ultrasound-guided fine needle aspiration was used in establishing the diagnosis in 4 cases of malignant peripheral nerve sheath tumor. Sonographic and cytologic characteristics are discussed. Because of its availability and ease of use, axillary ultrasonography with fine needle aspiration can be an initial diagnostic step for suspected brachial plexus tumors. PMID:18320983

  9. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1993-05-15

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer.

  10. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    International Nuclear Information System (INIS)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun

    1993-01-01

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer

  11. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2017-11-09

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P 20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  12. Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle.

    Science.gov (United States)

    Tang, Zhouwen; Igbinomwanhia, Efehi; Elhanafi, Sherif; Othman, Mohamed O

    2016-01-01

    Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV) biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-RV biliary drainage procedures at a single center. Patients who failed ERCP during the same session for benign or malignant biliary obstruction underwent EUS-RV using a flexible, nitinol covered, 19-gauge needle for biliary access and guide wire manipulation. Result. 24 patients underwent EUS-RV biliary drainage via extrahepatic access while 1 attempt was via intrahepatic access. The technical success rate was 80%, including 83.3% of cases via extrahepatic access. There was no significant difference in success rate of inpatient and outpatient procedures, benign or malignant indications, or type of guide wire used. Adverse events included mild pancreatitis (3 patients) and cholangitis (1 patient). Conclusion. A flexible 19-gauge needle for biliary access can be safe and effective when used to perform EUS-RV biliary drainage. Direct comparison between the nitinol needle and conventional metal needles in the performance of EUS guided biliary drainage is needed.

  13. Endoscopic ultrasound-guided fine-needle aspiration cytology in the evaluation of suspected tuberculosis in patients with isolated mediastinal lymphadenopathy

    DEFF Research Database (Denmark)

    Puri, R.; Vilmann, P.; Sud, R.

    2010-01-01

    Patients with suspected tuberculosis without pulmonary lesions and with mediastinal lymphadenopathy often pose a diagnostic challenge. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) cytology is an established modality to evaluate mediastinal and abdominal lesions. The aim...

  14. Pancreatic metastases from ocular malignant melanoma: the use of endoscopic ultrasound-guided fine-needle aspiration to establish a definitive cytologic diagnosis: a case report

    Directory of Open Access Journals (Sweden)

    Diogo Turiani Hourneaux De Moura

    2016-12-01

    Full Text Available Abstract Background When encountering solid pancreatic lesions, nonpancreatic primary metastases are rare and differentiating a metastasis from a primary neoplastic lesion is challenging. The clinical presentation and radiologic features can be similar and the possibility of a pancreatic metastasis should be considered when the patient refers to a history of a different primary cancer. Endoscopic ultrasound offers a key anatomical advantage in accessing the pancreas and endoscopic ultrasound-guided fine-needle aspiration has become the gold standard method for diagnosing pancreatic lesions. Case presentation A 58-year-old white Hispanic woman with a history of uveal malignant melanoma, presented with abdominal pain and jaundice. On admission, laboratory tests were performed (her total bilirubin was 6.37 mg/dL with a direct fraction of 5.30 mg/dL. Cross-sectional, abdominal computed tomography with contrast, showed a low-attenuating lesion localized in the pancreatic head (measuring 4 × 3 cm and a thinner section of the distal bile duct suspicious for compression. Our patient was scheduled for an endoscopic ultrasound-guided fine-needle aspiration to establish a diagnosis. Endoscopic ultrasound showed a solid, hypoechoic, well-defined lesion with regular contours (measuring 3.17 × 2.61 cm, localized between the head and neck of the pancreas. Endoscopic ultrasound-guided fine-needle aspiration was performed with a 22G needle and cytology confirmed the diagnosis of metastatic melanoma. Our patient subsequently underwent right orbital exenteration, followed by duodenopancreatectomy without complications. At the moment our patient is receiving adjuvant chemotherapy at an outside oncology clinic. Conclusions To the best of our knowledge, this is a very rare presentation of an ocular malignant melanoma with an isolated pancreatic metastasis causing symptomatic biliary obstruction. Endoscopic ultrasound-guided fine-needle aspiration has

  15. Endoscopic ultrasound-guided fine-needle tissue acquisition - A review and update of literature

    Directory of Open Access Journals (Sweden)

    Benjamin Tharian

    2015-01-01

    Full Text Available Ever since the first endoscopic ultrasound-guided fine needle aspiration (FNA was done in 1992, the procedure has evolved to become an indispensable tool for tissue acquisition in patients with gastrointestinal tumors and periluminal lesions. With the growing evidence of neoadjuvant therapy and research into intratumoral therapy, the need to obtain tissue diagnosis for tumors is quite apparent. This review provides an overall perspective to the endosonographer on various issues that are a key for best practices in FNA, in addition to being an update for practicing experienced endosonographers.

  16. INITIAL EXPERIENCE WITH ENDOSCOPIC ULTRASOUND-GUIDED FINE NEEDLE ASPIRATION OF RENAL MASSES: indications, applications and limitations

    Directory of Open Access Journals (Sweden)

    Renata Nobre MOURA

    2014-12-01

    Full Text Available Context Tissue sampling of renal masses is traditionally performed via the percutaneous approach or laparoscopicaly. The utility of endoscopic ultrasound to biopsy renal lesions it remains unclear and few cases have been reported. Objectives To evaluate the feasibility and outcome of endoscopic ultrasound fine needle aspiration of renal tumors. Methods Consecutive subjects undergoing attempted endoscopic ultrasound fine needle aspiration of a kidney mass after evaluation with computerized tomography or magnetic resonance. Results Ten procedures were performed in nine male patients (median age 54.7 years on the right (n = 4 and left kidney (n = 4 and bilaterally (n = 1. Kidney masses (median diameter 55 mm ; range 13-160 mm were located in the upper pole (n = 3, the lower pole (n = 2 and the mesorenal region (n = 3. In two cases, the mass involved more than one kidney region. Surgical resection confirmed renal cell carcinoma in six patients in whom pre-operative endoscopic ultrasound fine needle aspiration demonstrated renal cell carcinoma. No complications were reported. Conclusions Endoscopic ultrasound fine needle aspiration appears as a safe and feasible procedure with good results and minimal morbidity.

  17. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  18. Endoscopic ultrasound-guided fine-needle aspiration cytology in the evaluation of suspected tuberculosis in patients with isolated mediastinal lymphadenopathy

    DEFF Research Database (Denmark)

    Puri, R.; Vilmann, P.; Sud, R.

    2010-01-01

    Patients with suspected tuberculosis without pulmonary lesions and with mediastinal lymphadenopathy often pose a diagnostic challenge. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) cytology is an established modality to evaluate mediastinal and abdominal lesions. The aim...... of the present study was to evaluate the role of EUS-FNA in isolated mediastinal lymphadenopathy in patients suspected of having tuberculosis....

  19. Yield and Safety Profile of Ultrasound Guided Fine Needle Aspiration Cytology (FNAC) of Lymph Nodes

    International Nuclear Information System (INIS)

    Sattar, A.; Wahab, S.; Javed, A.; Shamim, S. H.

    2016-01-01

    Objective: To determine the re-biopsy rate, positive yield and safety profile of ultrasound guided fine needle aspiration cytology (FNAC) in cervical lymph nodes in terms of its complications and repeat procedures. Study Design: An analytical study. Place and Duration of Study: Department of Vascular and Interventional Radiology, Dow University Hospital, Dow University of Health Sciences, Karachi, from June to December 2013. Methodology: Eighty neck swellings, which were found to be lymph nodes on ultrasound, underwent ultrasound guided FNAC, from outpatients. Lymph nodes which were included in the study were those that were not easily palpable, located near major blood vessels, where patient refused of direct palpation and wanted image guided FNAC, those directly sent by physician for image guided FNAC and where blind biopsy remained inconclusive. Patients who refused on explanation or did not give consent were excluded. Complications and repeat biopsy were noted. Result: This study consisted of 80 cases, of which 51 cases (63.75 percentage) were female and 29 cases (36.25 percentage) were male. Repeat biopsy was required in 1 case (1.6 percentage). There were no procedure-related complications. A total of 44 cases (55 percentage) revealed evidence suggesting or confirming the existence of tuberculosis. Rest of the others showed other benign lesions, reactive lymphadenopathy and malignancy. Conclusion: Ultrasound guided FNAC is a safe procedure with low re-biopsy rate that aids diagnosis. The predominant cause of cervical lymphadenopathy in this study was tuberculous lymphadenitis. (author)

  20. Prospective evaluation of EUS-guided fine needle biopsy in pancreatic mass lesions

    DEFF Research Database (Denmark)

    Larsen, M H; Fristrup, C W; Detlefsen, S

    2018-01-01

    Background and study aim : Due to the scarcity of specific data on endoscopic ultrasound (EUS)-guided fine-needle biopsies (SharkCore) FNB in the evaluation of pancreatic lesions, we performed a prospective study of the diagnostic performance of EUS SharkCore FNB in patients with pancreatic lesions...

  1. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  2. Ultrasound guided fine needle aspiration cytology versus core biopsy in the preoperative assessment of non-palpable breast lesions

    International Nuclear Information System (INIS)

    Ahmed, M.E.; Ahmad, I.

    2010-01-01

    Background: Breast screening is a method of detecting breast cancer at a very early stage. Most of the lesions detected by screening are not malignant. Objective of this study was to compare ultrasound guided fine needle aspiration cytology and core biopsy in the preoperative assessment of non-palpable breast lesions. Methods: The study was conducted prospectively at Department of Radiology, Shaukat Khanum Memorial Cancer Hospital and Research Centre, Pakistan from March 2004 to February 2005. All the patients underwent fine needle aspiration cytology and core biopsy. Later on, all of them had excision biopsy/ mastectomy. Prospectively 80 patients were studied; information was collected on a specifically designed form according to inclusion criteria. The patient age, sex, medical record number and side of lesion were recorded. Clinical history of duration of lump was also taken. Informed consent was obtained. Results: The age of patients were ranges from 20-71 years, with mean of 44.31+- 11.002 and the maximum number of patients 28 (35.3%) was between the ages 50 - 59 years. The sensitivity of FNAC was 92.85%, while the specificity of was 90% and the accuracy rate was 92.1%. The sensitivity of core biopsy was 94.64%, specificity 91.30% and accuracy rate was 94.87%. Conclusion: Fine Needle Aspiration has been found to be an extremely useful method for the diagnosis of lumps of breast. The accuracy and the sensitivity of diagnosis on fine needle aspiration cytology were high. (author)

  3. Initial experience with new dedicated needles for laparoscopic ultrasound-guided fine-needle aspiration and histological biopsies

    DEFF Research Database (Denmark)

    Mortensen, M B; Durup, J; Pless, T

    2001-01-01

    BACKGROUND AND STUDY AIMS: Laparoscopic ultrasonography (LUS) is an important imaging modality during laparoscopic staging of intra-abdominal malignancies, but LUS-assisted biopsy is often difficult or impossible. We report a newly developed inbuilt biopsy system for direct LUS-guided fine......-needle aspiration (FNA) and Tru-cut biopsies. PATIENTS AND METHODS: LUS-guided biopsy was performed in 20 patients with upper gastrointestinal tract tumors. The biopsied lesions had either not been previously detected by other imaging modalities or had been inaccessible, or the biopsy sample had been inadequate...... were good or acceptable in 18 patients (90%). Slight needle deviation (material was obtained, but pathological examination was impossible owing...

  4. Ultrasound-guided fine needle aspiration of thyroid nodules: A consensus statement by the Korean Society of Thyroid Radiology

    International Nuclear Information System (INIS)

    Lee, Young Hen; Baek, Jung Hwan; Jung, So Lyoung; Kwak, Jin Young; Kim, Ji Hoon; Shin, Jung Hee

    2015-01-01

    Ultrasound (US)-guided fine needle aspiration (US-FNA) has played a crucial role in managing patients with thyroid nodules, owing to its safety and accuracy. However, even with US guidance, nondiagnostic sampling and infrequent complications still occur after FNA. Accordingly, the Task Force on US-FNA of the Korean Society of Thyroid Radiology has provided consensus recommendations for the US-FNA technique and related issues to improve diagnostic yield. These detailed procedures are based on a comprehensive analysis of the current literature and from the consensus of experts.

  5. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    Science.gov (United States)

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  6. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    Science.gov (United States)

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  7. Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    In Hye Song

    2015-03-01

    Full Text Available Background: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. Methods: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. Results: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. Conclusions: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected.

  8. Role of endoscopic ultrasound-guided fine needle aspiration and ultrasound-guided fine-needle aspiration in diagnosis of cystic pancreatic lesions

    Science.gov (United States)

    Okasha, Hussein Hassan; Ashry, Mahmoud; Imam, Hala M. K.; Ezzat, Reem; Naguib, Mohamed; Farag, Ali H.; Gemeie, Emad H.; Khattab, Hani M.

    2015-01-01

    Background and Objective: The addition of fine-needle aspiration (FNA) to different imaging modalities has raised the accuracy for diagnosis of cystic pancreatic lesions. We aim to differentiate benign from neoplastic pancreatic cysts by evaluating cyst fluid carcinoembryonic antigen (CEA), carbohydrate antigen (CA19-9), and amylase levels and cytopathological examination, including mucin stain. Patients and Methods: This prospective study included 77 patients with pancreatic cystic lesions. Ultrasound-FNA (US-FNA) or endoscopic ultrasound-FNA (EUS-FNA) was done according to the accessibility of the lesion. The aspirated specimens were subjected to cytopathological examination (including mucin staining), tumor markers (CEA, CA19-9), and amylase level. Results: Cyst CEA value of 279 or more showed high statistical significance in differentiating mucinous from nonmucinous lesions with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 73%, 60%, 50%, 80%, and 65%, respectively. Cyst amylase could differentiate between neoplastic and nonneoplastic cysts at a level of 1043 with sensitivity of 58%, specificity of 75%, PPV of 73%, NPV of 60%, and accuracy of 66%. CA19-9 could not differentiate between neoplastic and nonneoplastic cysts. Mucin examination showed a sensitivity of 85%, specificity of 95%, PPV of 92%, NPV of 91%, and accuracy of 91% in differentiating mucinous from non-mucinous lesions. Cytopathological examination showed a sensitivity of 81%, specificity of 94%, PPV of 94%, NPV of 83%, and accuracy of 88%. Conclusion: US or EUS-FNA with analysis of cyst CEA level, CA19-9, amylase, mucin stain, and cytopathological examination increases the diagnostic accuracy of cystic pancreatic lesions. PMID:26020048

  9. Microscopic findings in EUS-guided fine needle (SharkCore) biopsies with type 1 and type 2 autoimmune pancreatitis

    DEFF Research Database (Denmark)

    Detlefsen, Sönke; Joergensen, Maiken Thyregod; Mortensen, Michael Bau

    2017-01-01

    The International Consensus Diagnostic Criteria (ICDC) for the diagnosis of autoimmune pancreatitis (AIP) include the histological criterion that is based on either pancreatic core needle biopsies (CNBs) or surgical specimens. However, CNBs are difficult to obtain by endoscopic ultrasound (EUS......). EUS fine-needle aspiration (EUS-FNA) cytology is usually not sufficient for the diagnosis of AIP, but may sometimes contain tissue microfragments. Another approach is EUS-guided histological fine-needle biopsy (EUS-FNB), using needles such as the SharkCore or ProCore needle. Published data regarding...... EUS-guided SharkCore FNB for the diagnosis of AIP are lacking. We aimed to describe our histological findings in one type 1 and two type 2 AIP patients who underwent EUS SharkCore FNB. The EUS-FNBs of two patients fulfilled the histological level 2 ICDC for type 1 AIP or type 2 AIP. The EUS-FNB of one...

  10. Fine-needle trucut biopsy versus fine-needle aspiration cytology with ultrasound guidance in the abdomen

    International Nuclear Information System (INIS)

    O'Connell, A.M.; Keeling, F.; Given, M.; Logan, M.; Lee, M.J.

    2008-01-01

    Historically, fine-needle aspiration cytology (FNAC) has varying sensitivity, specificity and accuracy in the diagnosis of abdominal lesions with a high insufficient sampling rate. We compared 20-G fine-needle trucut biopsy (FNTB) with FNAC results in the biopsy of solid abdominal tumours. A retrospective review of 171 (128x 20-G FNTB and 43x FNAC) ultrasound-guided biopsies of abdominal tumours on 157 patients (male : female 85:72, mean age 61.25 years) were carried out. One hundred and seventy-one biopsies were carried out: liver 109, pancreas 19, lumph node 10, omentum 5, right iliac fossa mass 6, adrenal 6 and others 16. An average of 2.06 and 1.97 passes (range 1-4) were carried out per FNTB and FNAC, respectively. A definitive diagnosis was made in 122/128 biopsies (95.3%) and 32/43 biopsies (74.4%) for FNTB and FNAC, respectively. Diagnoses consisted of metastatic liver disease (74/171), pancreatic adenocarcinoma (10/171), lymphoma (8/171) and others (33/171) and benign (29/171). No significant complications occurred in either group. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 87, 100, 100, 50, 84.4 and 93.1, 100, 100, 60, 71.4 for FNTB and FNAC, respectively. A greater and more consistent positive diagnosis rate is yielded by 20-G FNTB (95.3%) that FNAC (74.4%). The diagnostic accuracy of FNTB is 84.4% cmopared with 69.8% for FNAC. A greater insufficient sampling rate occurs with FNAC (25.6%) than with FNTB (4.7%). For abdominal biopsy, 20-G FNTB needles have a much higher yield than FNAC with no increase in complications. FNTB is the preferred choice, particularly where cytological assistance at the time of biopsy is unavailable.

  11. Ultrasound-guided fine-needle aspiration biopsy of the thyroid.

    Science.gov (United States)

    Tambouret, R; Szyfelbein, W M; Pitman, M B

    1999-10-25

    We reviewed the Massachusetts General Hospital experience with ultrasound-guided fine-needle aspiration biopsies (FNABs) of the thyroid to determine the indications, rate of unsatisfactory smears, correlation with excisional biopsy results, and verification of efficient use of personnel time. All radiologically guided FNABs of the thyroid from January 1993 through June 1997 were reviewed. As a measure of efficient use of technologist time, a sample of times spent by the technologist during the procedure for 20 cases in 1993 and 1997 was compared with that of an equal number of random nonthyroid image guided FNABs. Two hundred-ninety FNABs were identified in 251 patients, representing 12% of all thyroid FNABs and 11% of all radiologically guided FNABs. Indications in the 251 patients included multiple nodules (78), solitary nodules (61), complex nodules (39), prior failed FNAB (39), thyroid bed abnormalities post-thyroidectomy (21), difficult access (7), and investigation of recurrent tumor in residual thyroid lobe (6). Available records indicated 118 lesions were palpable and 45 were nonpalpable; the physical examination characteristics of the remainder (88) were not stated. Diagnoses included 44 unsatisfactory cases (15%), 103 macrofollicular lesions, 20 microfollicular lesions, 26 mixed macro/microfollicular lesions, 5 oxyphilic lesions, 1 trabecular pattern, 15 nonspecific follicular cell pattern, 9 follicular cell atypia, 30 cysts, 11 thyroiditis, 23 malignant tumors, and 3 other (1 parathyroid, 2 lymph node). Eighty-nine FNABs from 76 patients had subsequent surgical biopsy. Excisional biopsies in 14 unsatisfactory FNABs were benign. In the remaining 75 FNABs from 67 patients, 18 malignancies on FNAB were correctly diagnosed, but 3 other papillary carcinomas were only qualified as atypical follicular cells on cytology. No false-positive cases occurred. Of 15 macrofollicular lesions on cytology, 10 were adenomas on excision, only 2 of which were microfollicular

  12. Eosinophilic esophageal myositis diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy: a case report.

    Science.gov (United States)

    Igarashi, Ryo; Irisawa, Atsushi; Shibukawa, Goro; Yamabe, Akane; Fujisawa, Mariko; Sato, Ai; Maki, Takumi; Arakawa, Noriyuki; Yoshida, Yoshitsugu; Yamamoto, Shogo; Ikeda, Tsunehiko

    2016-10-01

    Eosinophilic esophagitis (EoE) is diagnosed by microscopic findings of eosinophilic infiltration into the squamous epithelium. In contrast, another disease concept termed "eosinophilic esophageal myositis (EoEM)" has been proposed, whereby there is eosinophilic infiltration into the muscularis propria instead. A 60-year-old man was referred to our hospital for chest pain, dysphagia, and several episodes of esophageal food impaction. Although EoE was suspected based on clinical features, biopsy specimens showed no mucosal eosinophilic infiltration. Endoscopic ultrasound (EUS) showed thickening of the muscularis propria layer and subsequent EUS-guided fine-needle aspiration biopsy (EUS-FNA) revealed eosinophilic infiltration into the muscularis propria. Although the patient's symptoms gradually improved after steroid administration, complete remission was not achieved after 1 year of treatment. This case may reflect a disorder distinct from typical EoE based on eosinophilic infiltration of the muscularis propria but not the squamous epithelium, and we, therefore, diagnosed it as EoEM using the EUS-FNA findings as reference.

  13. The Utility of Endoscopic Ultrasound Guided Fine Needle Aspiration in the Diagnosis of Infectious Diseases—Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Mauro Ajaj Saieg

    2013-01-01

    Full Text Available Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA is a fast and minimally invasive methodology with a crucial impact on patients’ management. It has an important and established role in the diagnosis and staging of mediastinal and abdominal malignancies, but little is discussed in the literature on the usefulness of this technique in the diagnosis of infectious diseases. In the current report, we present three different cases where EUS was essential for reaching the diagnosis of tuberculosis and paracoccidiodomicosis in cases otherwise seen as malignant. In conclusion, EUS was successful not only in obtaining enough cells for morphological analysis, but also for the production of cell blocks and assessment of the presence of the microorganisms by special stains. EUS allied to fine needle biopsy was an important tool in determining diagnoses of enlarged lymph nodes, revealing the diagnosis of infectious diseases in cases otherwise seen as malignant. The wide use of this methodology in cases such as those reported here cannot only rule out malignancy, but also aid critically ill patients by installing early proper therapy without the need for aggressive interventions.

  14. The value of ultrasound with ultrasound-guided fine-needle aspiration biopsy compared to computed tomography in the detection of regional metastases in the clinically negative neck

    International Nuclear Information System (INIS)

    Takes, Robert P.; Righi, Paul; Meeuwis, Cees A.; Manni, Johannes J.; Knegt, Paul; Marres, Henri A.M.; Spoelstra, Hubert A.A.; Boer, Maarten F. de; Mey, Andel G.L. van der; Bruaset, I.; Ball, Valerie; Weisberger, Edward; Radpour, Shokri; Kruyt, Rene H.; Joosten, Frank B.M.; Lameris, Johan S.; Oostayen, Jacques A. van; Kopecky, Kenyon; Caldemeyer, Karen; Henzen-Logmans, Sonja C.; Wiersma-van Tilburg, J.M.; Bosman, Fred T.; Krieken, J. Han J.M. van; Hermans, Jo; Baatenburg de Jong, Robert J.

    1998-01-01

    Purpose: Head and neck oncologists have not reached consensus regarding the role of contemporary imaging techniques in the evaluation of the clinically negative neck in patients with head and neck squamous cell carcinoma (HNSCC). The purpose of the present study was to compare the accuracy of ultrasound with guided fine-needle aspiration biopsy (UGFNAB) and computed tomography (CT) in detecting lymph node metastasis in the clinically negative neck. Methods and Materials: Sixty-four neck sides of patients with HNSCC were examined preoperatively by ultrasound/UGFNAB and CT at one of five participating tertiary care medical centers. The findings were correlated with the results of histopathologic examination of the neck specimen. Results: Ultrasound with guided fine-needle aspiration biopsy was characterized by a sensitivity of 48%, specificity of 100%, and overall accuracy of 79%. Three cases had nondiagnostic aspirations using UGFNAB and were excluded. CT demonstrated a sensitivity of 54%, specificity of 92%, and overall accuracy of 77%. UGFNAB detected two additional metastases not visualized on CT, whereas CT detected no metastases not seen on UGFNAB. The results of UGFNAB were similar between the participating centers. Conclusions: Approximately one half of the clinically occult nodal metastases in our patient group were identified by both CT and UGFNAB. Overall, UGFNAB and CT demonstrated comparable accuracy. The sensitivity of CT was slightly better than UGFNAB, but the latter remained characterized by a superior specificity. The results of CT and UGFNAB did not appear to be supplementary. The choice of imaging modality for staging of the clinically negative neck depends on tumor site, T-stage, and experience and preference of the head and neck oncologist. If CT is required for staging of the primary tumor, additional staging of the neck by UGFNAB does not provide significant additional value

  15. Diagnosis of verminous pneumonia via sonography-guided fine-needle pulmonary parenchymal aspiration in a cat

    Directory of Open Access Journals (Sweden)

    Jennifer Gambino

    2016-04-01

    Full Text Available Case summary A 9-year-old, male neutered, indoor–outdoor domestic shorthair cat from the northern Alabama countryside presented for a 3 week history of coughing, lethargy and an episode of self-resolving dyspnea that occurred 1 week prior to presentation. Three-view thoracic radiographs revealed a moderate-to-severe, diffuse, mixed bronchial to structured interstitial (miliary-to-nodular pulmonary pattern in all lung lobes with peribronchial cuffing and multifocal areas of mild patchy alveolar opacity. Ultrasound-guided evaluation and fine-needle aspiration of the caudodorsal lung parenchyma was performed with sedation. Cytology revealed many widely scattered Aelurostrongylus abstrusus larvae and ova. Upon the confirmed diagnosis of A abstrusus verminous pneumonia, treatment with fenbendazole and selamectin resulted in complete resolution of clinical signs within 6 weeks of the initial diagnosis. Relevance and novel information We report herein the first documented case in the Americas of A abstrusus verminous pneumonia diagnosed via cytologic evaluation of an in vivo, percutaneous ultrasound-guided fine-needle aspirate of affected lung. Additionally, to our knowledge, we offer the first account of the sonographic (pulmonary features of the disease.

  16. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  17. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  18. The efficacy of an ultrasound-guided core needle biopsy with an 18G cutting needle for the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Jung, Sung Hwa; Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon; Cho, Jae Ho; Jang, Han Won; Lee, Jae Kyo; Choi, Joon Hyuk

    2008-01-01

    The objective of this study is to evaluate the efficacy and safety of an ultrasound-guided core needle biopsy with an 18G cutting needle in patients suspected of having a pancreatic disease by analyzing the diagnostic performance and complication rate. The study population comprised 35 consecutive patients who underwent an ultrasound-guided core needle biopsy using a high-speed biopsy gun accompanied with an 18G cutting-type needle between May of 2001 and October of 2005. The diagnostic performance (i.e., the acquisition rate and diagnostic accuracy) and complications associated with core needle biopsies were evaluated for its efficacy and safety. Thirty-six sessions of ultrasound-guided core needle biopsies were performed in 35 consecutive patients. All patients, except two (serous cystadenoma and autoimmune pancreatitis) were diagnosed with various subtypes of pancreatic cancer. The acquisition rate and diagnostic accuracy were 97% (35/36) and 94% (34/36), respectively. A complication occurred only in one patient (3%), which further proved to be a delayed complication (i.e., needle tract implantation). According to our findings, the ultrasound-guided core needle biopsy is a viable and safe method for the diagnosis of pancreatic diseases. Moreover, it enables the diagnosis of the pancreatic cancer subtype

  19. Ultrasound-guided needle aspiration of parotid abscess

    Directory of Open Access Journals (Sweden)

    André Takahashi

    2012-01-01

    Full Text Available Ultrasound (US has been used as a tool for parotid abscess diagnosis and treatment. The present article aimed to report a case of 72-year-old woman with parotid abscess treated by US-guided needle aspiration and conventional surgical drainage. Along with the clinical report, indications, advantages, and limitations of the method are discussed.

  20. An ultrasound needle insertion guide in a porcine phantom model.

    Science.gov (United States)

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  1. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    Science.gov (United States)

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  2. The role of ultrasound and ultrasound-guided fine needle aspiration biopsy of lymph nodes in patients with skin tumours

    International Nuclear Information System (INIS)

    Solivetti, Francesco Maria; Elia, Fulvia; Santaguida, Maria Giulia; Guerrisi, Antonino; Visca, Paolo; Cercato, Maria Cecilia; Di Carlo, Aldo

    2014-01-01

    The primary aim of this study was to evaluate the diagnostic accuracy of ultrasound (US) in the study of superficial lymph nodes during the follow-up of patients surgically treated for skin tumours. The secondary objective was to compare positive cytological results with histological reports. From 2004 to 2011, 480 patients (male/female: 285/195; median age 57 years; prevalent skin tumour: melanoma) underwent US-guided fine-needle aspiration biopsy (FNAB) of suspicious recurrent lymph nodes. An expert radiologist first performed US testing of the lymph nodes, expressing either a negative or positive outcome of the test. Subsequently, US-guided FNAB was performed. FNAB positive patients were subjected to lymphadenectomy; the patients who tested negative underwent the follow-up. The size of lymph nodes was ≤ 2 cm in 90% of cases. Out of the 336 (70%) US “positive” patients, 231 (68.8%) were FNAB positives. Out of the 144 (30%) US “negatives”, 132 (91.7%) were FNAB negatives. The sensitivity and specificity of the US were 95% and 55.7%, respectively; the negative predictive value was 91.7% and the positive predictive value was 68.8%. Definitive histological results confirmed FNAB positivity in 97.5% of lymphadenectomies. US is a sensitive method in the evaluation of superficial lymph nodes during the follow-up of patients with skin tumours. High positive predictive value of cytology was confirmed

  3. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    Science.gov (United States)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  4. Clinical impact of endoscopic ultrasound-guided fine needle aspiration biopsy in patients with upper gastrointestinal tract malignancies. A prospective study

    DEFF Research Database (Denmark)

    Mortensen, M B; Pless, T; Durup, J

    2001-01-01

    BACKGROUND AND STUDY AIMS: Several studies have evaluated the accuracy of endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNAB) in the upper gastrointestinal tract, but so far no studies have specifically evaluated the clinical impact of EUS-FNAB in upper gastrointestinal tract......% in esophageal, gastric, and pancreatic cancer, respectively. The staging-related clinical impact was similar for all three types of cancer (11-12.5%), whereas the diagnosis-related impact was highest in pancreatic cancer patients (86%). EUS-FNAB was inadequate in 13% and gave false-negative results in 5......%. The overall sensitivity, specificity and accuracy for EUS-FNAB were 80%, 78% and 80%, respectively. No complications related to the biopsy procedure were seen. CONCLUSIONS: If EUS-FNAB was performed only in cases where a positive malignant result would change patient management, then approximately one out...

  5. Scan-guided fine needle aspiration biopsy in malignant hepatic disease

    International Nuclear Information System (INIS)

    Johansen, P.; Svendsen, K.N.

    1978-01-01

    The method of scan-guided fine needle aspiration biopsy of the liver is described, and the diagnostic value of this combined method in the diagnosis of malignant hepatic disease is evaluated in 83 confirmed cases, showing a specificity of 100% and a sensitivity of 94%. The combined method is compared to liver scanning alone and to Menghini biopsy. Different methods for the diagnosis of malignant hepatic disease are discussed, and it is concluded that scan-guided fine needle aspiration biopsy has a diagnostic value only obtainable otherwise by a combination of liver scanning and biopsy during laparoscopy. Cytologic features in the two most common tumor types in this study, i.e., metastatic colonic adenocarcinoma and hepatocarcinoma, are presented along with a brief discussion of the specificity of the cytologic diagnosis of hepatocarcinoma

  6. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    A retrospective analysis of ultrasound-guided large core needle biopsies of breast lesions at a regional public hospital in Durban, KwaZulu-Natal, South Africa. ... Objective: To assess the influence of technical variables on the diagnostic yield of breast specimens obtained by using US-LCNB, and the sensitivity of detecting ...

  7. A Fresh Cadaver Model for the Instruction of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    McCrary, Hilary C; Faucett, Erynne A; Hurbon, Audriana N; Milinic, Tijana; Cervantes, Jose A; Kent, Sean L; Adamas-Rappaport, William J

    2017-07-01

    Objective The aim of our study is to determine if a fresh cadaver model (FCM) for the instruction of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules is a practical method for instruction. Study Design Pre- and postinstruction assessment of medical students' ability to perform US-guided FNA of artificially created thyroid nodules placed adjacent to the thyroid gland of a fresh cadaver. Setting University-based fresh cadaver laboratory. Subjects and Methods Study participants included a total of 17 first- and second-year medical students with minimal US training. Technical skills were assessed using a 10-item checklist. In addition, a cognitive assessment regarding the indications, contraindications, and complications of the procedure was completed. A postinstruction assessment was provided for participants 5 weeks after their initial assessment. Differences between pre- and postinstruction assessment scores of technical skills were analyzed using McNemar's test. The mean cognitive knowledge gain was analyzed using a paired 2-sample t test. Results Eight of 10 items on the skills checklist were statistically significant between pre- and postinstruction skills assessment ( P < .05). There was a statistically significant change in cognitive knowledge gain regarding the contraindications of the procedure ( P = .001), but not for indications or complications ( P = .104 and P = .111, respectively). Conclusion US-guided FNA continues to be an important diagnostic procedure in the workup of thyroid nodules, making it an essential skill to integrate into surgical skills lab. Our FCM for the instruction of US-guided FNA is the first of its kind, and this pilot study shows this is a viable method for instruction.

  8. Predictors of Malignancy and Recommended Follow-Up for Patients with Negative Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Suspected Pancreatic Lesions

    Directory of Open Access Journals (Sweden)

    Bret J Spier

    2009-01-01

    Full Text Available BACKGROUND: Endoscopic ultrasound (EUS with fine-needle aspiration (FNA can characterize and diagnose pancreatic lesions as malignant, but cannot definitively rule out the presence of malignancy. Outcome data regarding the length of follow-up in patients with negative or nondiagnostic EUS-FNA of pancreatic lesions are not well-established.

  9. Fine-needle aspirate cytology suggesting hepatic lipidosis in four cats with infiltrative hepatic disease.

    Science.gov (United States)

    Willard, M D; Weeks, B R; Johnson, M

    1999-12-01

    Four cats are reported in which cytology smears obtained by ultrasound-guided fine needle aspiration of the liver were interpreted as indicative of hepatic lipidosis. However, histopathology of hepatic tissue samples obtained with Tru-Cut-like needles or wedge biopsy revealed that the cats had inflammatory or neoplastic hepatic disease causing their clinical signs. Fine needle aspiration and cytology may not detect infiltrative lesions, particularly those that are nodular, multifocal, or localised around the portal regions. Fine needle aspirate cytology is a useful diagnostic procedure with many advantages, but care must be taken to avoid diagnosing hepatic lipidosis as the cause of illness when an infiltrative lesion is responsible. Copyright 1999 European Society of Feline Medicine.

  10. A serious game for learning ultrasound-guided needle placement skills.

    Science.gov (United States)

    Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann

    2012-11-01

    Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.

  11. [Novel echogenic needle for ultrasound-guided peripheral nerve block "Hakko type CCR"].

    Science.gov (United States)

    Takayama, Wataru; Yasumura, Rie; Kaneko, Takehiko; Kobayashi, Yoshiro; Kamada, Takaaki; Yoshikawa, Tamotsu; Aoyama, Yasuhiko

    2009-04-01

    A novel echogenic insulated nerve block needle (CCR-needle: Echogenic Needle Type CCR; Hakko, Japan) is commercially available since 2006 in Japan. This needle has three echogenic dimples, namely corner cube reflectors (CCR) on its tip. The CCR-needle will potentially provide a significant advantage for detecting the needle tip. In this report, we firstly evaluated this new disposable echogenic needle in simulation phantom, and demonstrated improved visibility of the needle tip. Afterwards, an interscalene brachial plexus block was performed on a male patient undergoing shoulder surgery. The needle insertion procedure was the "out of plane" ultrasound-guided technique using simultaneous electrical nerve stimulation. The surgery was successfully conducted without any complications.

  12. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    Science.gov (United States)

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect

  13. How to learn and to perform endoscopic ultrasound and endobronchial ultrasound for lung cancer staging

    DEFF Research Database (Denmark)

    Konge, Lars; Colella, Sara; Vilmann, Peter

    2015-01-01

    The learning of transesophageal ultrasound guided fine needle aspiration (FNA) (endoscopic ultrasound-FNA), and endobronchial ultrasound guided transbronchial needle aspiration (endosonography) should be based on the following steps: Acquiring theoretical knowledge, training on simulators, and su...

  14. Utility and Safety of Endoscopic Ultrasound With Bronchoscope-Guided Fine-Needle Aspiration in Mediastinal Lymph Node Sampling: Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Dhooria, Sahajal; Aggarwal, Ashutosh N; Gupta, Dheeraj; Behera, Digambar; Agarwal, Ritesh

    2015-07-01

    The use of endoscopic ultrasound with bronchoscope-guided fine-needle aspiration (EUS-B-FNA) has been described in the evaluation of mediastinal lymphadenopathy. Herein, we conduct a meta-analysis to estimate the overall diagnostic yield and safety of EUS-B-FNA combined with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), in the diagnosis of mediastinal lymphadenopathy. The PubMed and EmBase databases were searched for studies reporting the outcomes of EUS-B-FNA in diagnosis of mediastinal lymphadenopathy. The study quality was assessed using the QualSyst tool. The yield of EBUS-TBNA alone and the combined procedure (EBUS-TBNA and EUS-B-FNA) were analyzed by calculating the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each study, and pooling the study results using a random effects model. Heterogeneity and publication bias were assessed for individual outcomes. The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was calculated using proportion meta-analysis. Our search yielded 10 studies (1,080 subjects with mediastinal lymphadenopathy). The sensitivity of the combined procedure was significantly higher than EBUS-TBNA alone (91% vs 80%, P = .004), in staging of lung cancer (4 studies, 465 subjects). The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was 7.6% in the diagnosis of mediastinal adenopathy. No serious complication of EUS-B-FNA procedure was reported. Clinical and statistical heterogeneity was present without any evidence of publication bias. Combining EBUS-TBNA and EUS-B-FNA is an effective and safe method, superior to EBUS-TBNA alone, in the diagnosis of mediastinal lymphadenopathy. Good quality randomized controlled trials are required to confirm the results of this systematic review. Copyright © 2015 by Daedalus Enterprises.

  15. Role of endoscopic ultrasound-guided fine-needle aspiration in adrenal lesions: analysis of 32 patients

    Directory of Open Access Journals (Sweden)

    Rakesh K Gupta

    2018-01-01

    Full Text Available Objective: Endoscopic ultrasound-guided fine-needle aspiration cytology (EUS-FNAC is a precise and safe technique that provides both radiological and pathological diagnosis with a better diagnostic yield and minimal adverse events. EUS-FNAC led to the remarkable increase in the detection rate of incidentaloma found during radiologic staging or follow-up in various malignancy or unrelated conditions. Aims: We did this preliminary study with an aim to evaluate the role of EUS-FNA in diagnosing and classifying adrenal lesions, clinical impact, and compare the outcome with the previously published literature. Materials and Methods: We included 32 consecutive cases (both retrospective and prospective of EUS-guided adrenal aspirate performed over a period of 3.3 years. The indications for the aspirate in decreasing order were metastasis (most common carcinoma gall bladder > primary adrenal mass > disseminated tuberculosis > pyrexia of unknown origin. On EUS, 28 cases revealed space occupying lesion or mass (two cases bilateral and four cases revealed diffuse enlargement (two cases bilateral with a mean size of 21 mm. Results: The cytology reports were benign adrenal aspirate (43.8%, metastatic adenocarcinoma (15.6%, histoplasmosis (9.4%, tuberculosis (9.4%, round cell tumor (6.2%, adrenocortical carcinoma (3.1%, and descriptive (3.1%. Three cases (9.4% yielded inadequate sample. The TNM staging was altered in 22.23% of the cases by result of adrenal aspirate. Conclusions: EUS-FNA of the adrenal gland is a safe, quick, and sensitive and real-time diagnostic technique, which requires an integrated approach of clinician, endoscopist, and cytopathologist for high precision in diagnosis. Although the role of EUS-FNA for right adrenal is not much described, we found adequate sample yield in all the four patients that underwent the procedure.

  16. Ultrasound Guided Needle Aspiration versus Surgical Drainage in the management of breast abscesses: a Ugandan experience

    Directory of Open Access Journals (Sweden)

    Chandika Alphonce B

    2012-01-01

    Full Text Available Abstract Background Despite breast abscess becoming less common in developed countries, it has remained one of the leading causes of morbidity in women in developing countries. A randomized controlled trial was conducted at Mulago hospital complex in Kampala Uganda to establish whether ultrasound guided needle aspiration is a feasible alternative treatment option for breast abscesses. Results A total of 65 females with breast abscess were analyzed, of these 33 patients were randomized into the ultrasound guided needle aspiration and 32 patients in the Incision and drainage arm. The mean age was 23.12, most of them were lactating (66.2%, primipararous (44.6% with peripheral abscesses (73.8% located in the upper lateral quadrant (56%.The mean breast size was 3.49 cm. The two groups were comparably in demographic characteristic and breast abscess size. Survival analysis showed no difference in breast abscess healing rate between the two groups (Log rank 0.24 df 1 and P = 0.63. Incision and drainage was found to be more costly than ultrasound guided aspiration (cost effective ratio of 2.85. Conclusion Ultrasound guided needle aspiration is therefore a feasible and cost effective treatment option for both lactating and non lactating breast abscesses with a diameter up to 5 cm by ultrasound in an immune competent patient

  17. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, J-M; Polkowski, M; Larghi, A

    2011-01-01

    This article is part of a combined publication that expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about endoscopic ultrasound (EUS)-guided sampling in gastroenterology, including EUS-guided fine needle aspiration (EUS-FNA) and EUS-guided trucut biopsy (EU...

  18. Assessment of pain score and specimen adequacy for ultrasound-guided fine-needle aspiration biopsy of thyroid nodules

    Directory of Open Access Journals (Sweden)

    Liao LJ

    2017-12-01

    Full Text Available Li-Jen Liao,1 Wu-Chia Lo,1 Wan-Lun Hsu,2 Po-Wen Cheng,1 Cheng-Ping Wang3 1Department of Otolaryngology, Far Eastern Memorial Hospital, 2Genomics Research Center, Academia Sinica, 3Department of Otolaryngology, National Taiwan University Hospital, Taipei, Taiwan, Republic of China Objective: The aim of this study was to evaluate pain scores and specimen adequacy for ultrasound-guided fine-needle aspiration biopsy (US-FNAB of thyroid nodules without and with local anesthesia (LA. Materials and methods: The US-FNAB procedure was performed on 183 patients with and without LA. One puncture was made for solid nodules, and if patients could tolerate it, a two-puncture technique was used for nodules with a cystic change. Four-point verbal rating scores were assessed by a nursing assistant after completion of US-FNAB. To be an adequate specimen, at least six groups of follicular cells are required, and each group should contain at least 10 cells.Results: Immediately after US-FNAB, 92% of patients with LA and 80% without LA reported no or mild pain (p=0.01. Most patients tolerated the procedure well, with no pain (82.5% reported 5 minutes after the procedure. In univariate logistic regression, irregular boundary (odds ratio [OR]: 2.52, 95% confidence interval [CI]: 1.04–6.06, p=0.04, calcification (OR: 2.86, 95% CI: 1.06–7.76, p=0.04, and LA (OR: 0.35, 95% CI: 0.15–0.86, p=0.02 were significantly associated with immediate moderate or severe pain. Specimen adequacy was significantly associated with age (OR: 0.95, 95% CI: 0.92–0.97, p<0.01, heterogeneous echo-texture (OR: 1.76, 95% CI: 1.23–5.17, p=0.01, predominate solid architecture (OR: 2.78, 95% CI: 1.42–5.41, p<0.01, and the use of LA (OR: 3.34, 95% CI: 1.70–6.56, p<0.01. In multivariate logistic regression, patients receiving LA had lower risk of moderate or severe pain (OR: 0.25, 95% CI: 0.09–0.67, p=0.01 and higher chances of specimen adequacy (OR: 4.84, 95% CI: 2.17–10.7, p<0

  19. The value of preoperative ultrasound guided fine-needle aspiration cytology of radiologically suspicious axillary lymph nodes in breast cancer

    Directory of Open Access Journals (Sweden)

    Torill Sauer

    2014-01-01

    Full Text Available Background: Preoperative ultrasound (US and eventually US-guided fine-needle aspiration cytology (FNAC of suspicious axillary lymph nodes (ALN is a standard procedure in the work-up of suspicious breast lesions. Preoperative US FNAC may prevent sentinel node biopsy (SNB procedure in 24-30% of patients with early stage breast carcinoma. The aim of this study was to evaluate the institutional results of this preoperative diagnostic procedure. Materials and Methods: A total of 182 cases of preoperative FNAC of suspicious ALN where retrieved from the pathology files. The results were compared with the final histology and staging. False negative (FN FNAC cases were reviewed and possibly missed metastatic cases (2 were immunostained with the epithelial marker AE1/AE3. Results: There were no false positives, whereas 16 cases were FN. In all but one case the FN′s represented sampling error. Half of the 16 FN cases in this series were macrometastases. Discussion: About 83% of the preoperatively aspirated cases were N+, indicating that a radiologically suspicious ALN has a very high risk of being metastatic. Preoperative US guided FNAC from radiologically suspicious ALN is highly efficient in detecting metastases. Depending on national guidelines, a preoperative, positive ALN FNAC might help to stratify the patients as to SNB and/or ALN dissection.

  20. Two-dimensional mapping of needle visibility with linear and curved array for ultrasound-guided interventional procedure

    Science.gov (United States)

    Susanti, Hesty; Suprijanto, Kurniadi, Deddy

    2018-02-01

    Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and

  1. Endoscopic Ultrasound Fine-Needle Aspiration Characteristics of Primary Adenocarcinoma versus Other Malignant Neoplasms of The Pancreas

    Directory of Open Access Journals (Sweden)

    Veronika Gagovic

    2012-01-01

    Full Text Available BACKGROUND: Endoscopic ultrasound (EUS with fine-needle aspiration (FNA is often used to assist in the evaluation of pancreatic lesions and may help to diagnose benign versus malignant neoplasms. However, there is a paucity of literature regarding comparative EUS characteristics of various malignant pancreatic neoplasms (primary and metastatic.

  2. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid Nodules: is it Necessary to Use Local Anesthesia for the Application of One Needle Puncture?

    International Nuclear Information System (INIS)

    Kim, Dong Wook; Rho, Myung Ho; Kim, Ki Nam

    2009-01-01

    This study was designed to evaluate the difference in the degree of patient pain for an ultrasound-guided fine-needle aspiration biopsy (USFNAB) of a thyroid nodule with one needle puncture with and without local anesthesia. A total of 50 patients participated in the study. We examined prospective patients who would undergo US-FNABs of two thyroid nodules (larger than 10 mm maximum diameter), which were located in separate thyroid lobes. For one of these thyroid nodules, US-FNAB was performed following the administration of local anesthesia; for the other nodule, no anesthesia was administered. The application of anesthesia was alternatively administered between patients (either prior to the first US-FNAB procedure or prior to the second procedure). For all patients, the degree of pain during and after each US-guided FNAB was evaluated according to a 4-category verbal rating scale (VRS), an 11-point numeric rating scale (NRS) and a 100-mm visual analogue scale (VAS). The mean maximum diameters of thyroid nodules examined by US-FNAB with the use of local anesthesia and with no local anesthesia were 13.6 mm and 13.0 mm, respectively. There was no significant difference in nodule size (p > 0.05) between two groups. For the VRS, there were 27 patients with a higher pain score when local anesthesia was used and four patients with a higher pain score when no local anesthesia was administered. Nineteen patients had equivalent pain score for both treatments. This finding was statistically significant (p < 0.001). For the NRS, there were 33 patients with a higher pain score when local anesthesia was used and 10 patients with a higher pain score when no local anesthesia was administered. Seven patients had an equivalent pain score for each treatment. This finding was statistically significant (p < 0.001). For the VAS, there were 35 patients with a higher pain score when local anesthesia was used and 11 patients with a higher pain score where no local anesthesia was

  3. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    Science.gov (United States)

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  4. Acupuncture sensation during ultrasound guided acupuncture needling

    Science.gov (United States)

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  5. The diagnostic value of thyroglobulin concentration in fine-needle aspiration of the cervical lymph nodes in patients with differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Mikosinski, S.; Oszukowska, L.; Makarewicz, J.; Adamczewski, Z.; Lewinski, A.; Pomorski, L.; Sporny, S.

    2006-01-01

    Introduction: Recurrent differentiated thyroid cancer generally occurs first in the neck. Ultrasound is sensitive in detecting enlarged cervical lymph nodes but is not specific enough. Ultrasound-guided fine-needle biopsy increases the specificity but still may fail to detect a recurrence of the disease in the cystic metastatic lymph nodes. The aim of the study was to estimate the value of Tg concentration in the needle washout after fine-needle aspiration of suspicious lymph nodes. Material and methods: The 105 patients studied had presented one or more enlarged suspicious cervical lymph nodes. All had undergone total thyroidectomy and 131I ablative therapy. Serum thyroglobulin (Tg) concentration was within the 0.15 - 711.5 ng/ml range (mean 22.24 ng/ml) and Tg recovery range 94 - 100%. The positive Tg washout concentration cut-off value was established as equal to the mean plus two standard deviations of the Tg washout concentration of patients with negative cytology. Results: Lymph node involvement was diagnosed by cytology in 15 patients and in 28 lymph nodes. Positive Tg washout concentration was found in 22 patients and in 48 lymph nodes. All the lymph nodes which turned out to have positive cytology had a positive Tg washout concentration. All lymph nodes with positive cytology were positive in pathology. Seven patients and 20 lymph nodes with negative cytology were positive in the Tg washout concentration test. All but one patients and all but two lymph nodes with a positive Tg washout concentration had positive pathology. Conclusions: 1. Ultrasound-guided fine-needle biopsy is not sensitive enough to detect all metastatic lymph nodes. 2. The Tg washout concentration test is 100% sensitive in the detection of metastatic lymph nodes. 3. Cytology in ultrasound- guided fine-needle biopsy is 100% specific. 4. The Tg washout concentration test carries a risk of false-positive results. 5. Both methods should be used for early detection of metastatic lymph nodes

  6. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions

    Science.gov (United States)

    Alatawi, Abdullah; Beuvon, Frédéric; Grabar, Sophie; Leblanc, Sarah; Chaussade, Stanislas; Terris, Benoit; Barret, Maximilien

    2015-01-01

    Objectives Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using standard needles has a high diagnostic value in the evaluation of solid pancreatic masses. Fenestrated needles have been developed to improve the quality of EUS-guided tissue sampling by providing core biopsies (FNB). Methods Patients with solid pancreatic masses of >2 cm were prospectively included in our study and randomized to receive EUS sampling, using either a standard 22G FNA or a 22G Procore® FNB needle. The main study endpoint was the number of needle passes required to obtain a diagnosis in more than 90% of cases. Results We included 100 patients (male = 63, female = 37; mean age = 68.4 years) in our study. We found that 88% of the lesions were malignant, with a mean size of 32 mm. A sample adequate for diagnosis was obtained in more than 90% of cases after the second needle pass in the FNB group, versus the third needle pass in the FNA group. Slide cellularity and presence of tissue microfragments were significantly higher in the FNB group. Sensitivity for the diagnosis of malignancy was 88.4% versus 97.8% for the EUS-FNA and EUS-FNB group, respectively, while specificity for both techniques was 100%. No complications were recorded. Conclusions Although the accuracy of both needle types for proving malignancy was similar, a lower number of passes was required with the FNB needles to achieve the same contributive sample rate as with the FNA needles. FNB also improved the histopathological quality of specimens, suggesting an overall superiority of FNB sampling. PMID:26279842

  7. Radiographic-guided fine-needle aspiration of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Helvie, M.A.; Baker, D.E.; Adler, D.D.; Andersson, I.; Naylor, B.; Buckwalter, K.

    1989-01-01

    The authors have performed radiographically guided fine-needle aspirations (FNA) on 215 nonpalpable mammographically detected breast lesions, using a coordinate grid localization system. Aspirates were classified into five cytologic groups. With the most stringent cytologic criteria, the sensitivity was 98% and the specificity 95% for the detection of carcinoma. However, according to these strict cytologic criteria, only 46% of aspirates contained representative material. Forty-two of 74 lesions undergoing biopsy proved malignant. Sixteen percent of patients did not compete adequate mammographic follow-up. High sensitivity and specificity can be achieved with radiographically guided FNA. However, management decisions ultimately require integration of mammographic findings with cytologic results. Close cooperation between mammographer, surgeon, cytopathologist, and patients is mandatory for successful operation

  8. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  9. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    Science.gov (United States)

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  10. EUS-Guided Needle-Based Confocal Laser Endomicroscopy

    DEFF Research Database (Denmark)

    Bhutani, Manoop S; Koduru, Pramoda; Joshi, Virendra

    2015-01-01

    Endoscopic ultrasound (EUS) has emerged as an excellent tool for imaging the gastrointestinal tract, as well as surrounding structures. EUS-guided fine-needle aspiration (EUS-FNA) has become the standard of care for the tissue sampling of a variety of masses and lymph nodes within and around...... the gut, providing further diagnostic and staging information. Confocal laser endomicroscopy (CLE) is a novel endoscopic method that enables imaging at a subcellular level of resolution during endoscopy, allowing up to 1000-fold magnification of tissue and providing an optical biopsy. A new procedure...... that has been developed in the past few years is needle-based confocal laser endomicroscopy (nCLE), which involves a mini-CLE probe that can be passed through a 1 9-gauge needle during EUS-FNA. This enables the real-time visualization of tissue at a microscopic level, with the potential to further improve...

  11. Transrectal ultrasound and needle biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Tomaž Smrkolj

    2016-01-01

    Full Text Available In the last 25 years widespread use of prostatic specific antigen caused a stage migration of prostate cancer towards localized disease at diagnosis, which resulted in transrectal ultrasound biopsy to become standard in clinical practice. Transrectal ultrasound examination of the prostate is used to diagnose benign prostatic diseases, e.g. benign prostatic enlargement, prostatitis, prostatic and seminal vesicle cysts. It is also important in detection of obstructive causes of male infertility. Transrectal ultrasound examination is performed most often in needle biopsy for prostate cancer diagnosis. Besides guiding systematic tissue core biopsy, characteristic ultrasound changes enables target biopsies of suspect areas. The article describes indications, contraindications, antibiotic prophylaxis, various biopsy templates and complications of the needle biopsy. Experience with transrectal ultrasound guided biopsy at Department of urology at University medical center in Ljubljana is presented.

  12. Molecular Endoscopic Ultrasound for Diagnosis of Pancreatic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bournet, Barbara [Department of Gastroenterology, University Hospital Center Rangueil, 1 avenue Jean Poulhès, TSA 50032, 31059 Toulouse Cedex 9 (France); INSERM U1037, University Hospital Center Rangueil, Toulouse (France); Pointreau, Adeline; Delpu, Yannick; Selves, Janick; Torrisani, Jerome [INSERM U1037, University Hospital Center Rangueil, Toulouse (France); Buscail, Louis, E-mail: buscail.l@chu-toulouse.fr [Department of Gastroenterology, University Hospital Center Rangueil, 1 avenue Jean Poulhès, TSA 50032, 31059 Toulouse Cedex 9 (France); INSERM U1037, University Hospital Center Rangueil, Toulouse (France); Cordelier, Pierre [INSERM U1037, University Hospital Center Rangueil, Toulouse (France)

    2011-02-24

    Endoscopic ultrasound-guided fine needle aspiration-biopsy is a safe and effective technique in diagnosing and staging of pancreatic ductal adenocarcinoma. However its predictive negative value does not exceed 50% to 60%. Unfortunately, the majority of pancreatic cancer patients have a metastatic and/or a locally advanced disease (i.e., not eligible for curative resection) which explains the limited access to pancreatic tissue specimens. Endoscopic ultrasound-guided fine needle aspiration-biopsy is the most widely used approach for cytological and histological material sampling in these situations used in up to two thirds of patients with pancreatic cancer. Based on this unique material, we and others developed strategies to improve the differential diagnosis between carcinoma and inflammatory pancreatic lesions by analysis of KRAS oncogene mutation, microRNA expression and methylation, as well as mRNA expression using both qRT-PCR and Low Density Array Taqman analysis. Indeed, differentiating pancreatic cancer from pseudotumoral chronic pancreatitis remains very difficult in current clinical practice, and endoscopic ultrasound-guided fine needle aspiration-biopsy analysis proved to be very helpful. In this review, we will compile the clinical and molecular advantages of using endoscopic ultrasound-guided fine needle aspiration-biopsy in managing pancreatic cancer.

  13. Molecular Endoscopic Ultrasound for Diagnosis of Pancreatic Cancer

    International Nuclear Information System (INIS)

    Bournet, Barbara; Pointreau, Adeline; Delpu, Yannick; Selves, Janick; Torrisani, Jerome; Buscail, Louis; Cordelier, Pierre

    2011-01-01

    Endoscopic ultrasound-guided fine needle aspiration-biopsy is a safe and effective technique in diagnosing and staging of pancreatic ductal adenocarcinoma. However its predictive negative value does not exceed 50% to 60%. Unfortunately, the majority of pancreatic cancer patients have a metastatic and/or a locally advanced disease (i.e., not eligible for curative resection) which explains the limited access to pancreatic tissue specimens. Endoscopic ultrasound-guided fine needle aspiration-biopsy is the most widely used approach for cytological and histological material sampling in these situations used in up to two thirds of patients with pancreatic cancer. Based on this unique material, we and others developed strategies to improve the differential diagnosis between carcinoma and inflammatory pancreatic lesions by analysis of KRAS oncogene mutation, microRNA expression and methylation, as well as mRNA expression using both qRT-PCR and Low Density Array Taqman analysis. Indeed, differentiating pancreatic cancer from pseudotumoral chronic pancreatitis remains very difficult in current clinical practice, and endoscopic ultrasound-guided fine needle aspiration-biopsy analysis proved to be very helpful. In this review, we will compile the clinical and molecular advantages of using endoscopic ultrasound-guided fine needle aspiration-biopsy in managing pancreatic cancer

  14. Relationship of pancreatic mass size and diagnostic yield of endoscopic ultrasound-guided fine needle aspiration.

    Science.gov (United States)

    Siddiqui, Ali A; Brown, Lauren J; Hong, Shih-Kuang S; Draganova-Tacheva, Rossitza A; Korenblit, Jason; Loren, David E; Kowalski, Thomas E; Solomides, Charalambos

    2011-11-01

    Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is central to discerning the diagnosis of solid pancreatic tumors through tissue acquisition. Test performance is affected by a number of factors including location of mass within the pancreas, presence of onsite cytology technologist, and number of passes with the needle. The influence of tumor size has not been well studied. The objective of the current study was to determine whether the size of mass affects the diagnostic accuracy for solid pancreatic lesions aspirated under EUS guidance. Data were collected retrospectively on all patients with solid pancreatic masses undergoing EUS-FNA from June 2003 to August 2010. The cytology samples were reported as positive, suspicious for malignancy, atypical, negative, or nondiagnostic. The gold standard for a cytological diagnosis was histological confirmation or clinical follow-up of more than 6 months with repeat imaging. Patients were divided into five groups based upon lesion size as follows: (a) less than 1 cm, (b) 1-2 cm, (c) 2-3 cm, (d) 3-4 cm, and (e) greater than 4 cm. Performance characteristics of EUS-FNA including sensitivity, specificity, and accuracy were compared for each group. Accuracy was defined as the ratio of the sum of true-positive and true-negative values divided by the number of lesions. We identified 583 patients with solid pancreatic lesions in which EUS-FNA was performed and adequate cellularity was obtained (47% men, mean age 65 ± 1.4 (SE) years). Overall, 486 (83%) of lesions were pancreatic adenocarcinoma, 18 (3%) were neuroendocrine tumors, 12 (2%) were lymphomas, and 67 (12%) were benign lesions. The median size of the mass was 3 cm (range, 0.5-7 cm). A mean of 4.9 passes (range, 1-9 passes) was needed to obtain adequate samples from lesions. The overall yield of obtaining adequate samples for diagnosis was 85%. When stratified by size, the EUS-FNA sensitivity for lesions with size 4 cm was 40, 75.9, 86.9, 93

  15. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    Science.gov (United States)

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  16. Endoscopic ultrasound-guided fine-needle aspiration diagnosis of secondary tumors involving the pancreas: An institution′s experience

    Directory of Open Access Journals (Sweden)

    Ahmed K Alomari

    2016-01-01

    Full Text Available Background: Pancreatic masses may seldom represent a metastasis or secondary involvement by lymphoproliferative disorders. Recognition of this uncommon occurrence may help render an accurate diagnosis and avoid diagnostic pitfalls during endoscopic ultrasound-guided fine needle aspiration (EUS-FNA. In this study, we review our experience in diagnosing secondary tumors involving the pancreas. Materials and Methods: The electronic database of cytopathology archives was searched for cases of secondary tumors involving the pancreas at our institution and a total of 31 cases were identified. The corresponding clinical presentations, imaging study findings, cytological diagnoses, the results of ancillary studies, and surgical follow-up, if available, were reviewed. Results: Nineteen of the patients were male and 12 female, with a mean age of 66 years. Twenty-three patients (74% had a prior history of malignancy, with the latency ranging from 6 months to 19 years. The secondary tumors involving the pancreas included metastatic carcinoma (24 cases, metastatic sarcoma (3 cases, diffuse large B-cell lymphoma (2 cases, and plasma cell neoplasm (2 cases. The most common metastatic tumors were renal cell carcinoma (8 cases and lung carcinoma (7 cases. Correct diagnoses were rendered in 29 cases (94%. The remaining two cases were misclassified as primary pancreatic carcinoma. In both cases, the patients had no known history of malignancy, and no ancillary studies were performed. Conclusions: Secondary tumors involving the pancreas can be accurately diagnosed by EUS-FNA. Recognizing uncommon cytomorphologic features, knowing prior history of malignancy, and performing ancillary studies are the keys to improve diagnostic performance and avoid diagnostic pitfalls.

  17. Ultrasound-Guided Fine Needle Aspiration Cytology in the Assessment of Cervical Metastasis in Patients Undergoing Elective Neck Dissection

    International Nuclear Information System (INIS)

    Dabirmoghaddam, Payman; Sharifkashany, Shervin; Mashali, Leila

    2014-01-01

    In head and neck cancer patients, diagnosis of metastatic cervical adenopathy is essential for treatment planning and prognosis assessment. Treatment of patients with head and neck cancer with clinically negative cervical lymph node (N0) remains controversial. While routine neck treatment would result in overtreatment in many patients, observation may delay the diagnosis and decrease the patients’ survival. To gain insights into the unclear questions regarding the value of diagnostic modalities in patients with N0 neck, this study was designed to compare the diagnostic efficacy of palpation, ultrasonography (US) and ultrasound-guided fine needle aspiration (USGFNA) in detecting cervical lymph node metastasis. Forty-two patients with head and neck cancer who underwent US and USGFNA prior to elective neck dissection were studied. Histopathologic findings of the neck specimens were compared with each diagnostic technique. Of the 53 neck dissection specimens, histopathology showed metastases in 16 cases. The overall accuracy of USGFNA, US and palpation was 96%, 68% and 70%, respectively. The specificity of USGFNA was superior to palpation and US alone. USGFNA had the highest sensitivity, predictive value and accuracy in detecting cervical metastases compared with other performed tests. In our study, USGFNA was superior to palpation and US in detecting metastasis in clinically negative necks. This method can be recommended as a diagnostic tool in preoperative assessment of patients without palpable metastasis, but further investigations are needed before this modality could be considered as an alternative to elective neck dissection

  18. Comparison of diagnostic yield of endoscopic ultrasound-guided fine-needle aspiration cytology and cell block in solid lesions

    Directory of Open Access Journals (Sweden)

    Avinash Bhat Balekuduru

    2017-01-01

    Full Text Available Background and Aim: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA is a procedure of choice for the diagnostic evaluation of submucosal and periluminal lesions. Tissue sample can be obtained by EUS-FNA cytology (FNAC or cell block (CB. The aim of the present study is to compare diagnostic yield of EUS-FNA CB and cytology in the absence of onsite pathologist following a protocol-based EUS-FNA approach in solid lesions. Patients and Methods: Participants who underwent EUS-FNA at our center for solid submucosal or periluminal lesions (pancreas, lymph node, and liver between 2014 and 2016 were included, retrospectively. The indication for the procedure along with the clinical and other investigation details and the final etiological diagnosis were recorded on uniform structured data forms. The diagnostic yield of cytology and CB were compared using McNemar's test. The P < 0.05 was considered statistically significant. Results: EUS-FNA for solid lesion was performed in 130 lesions in 101 patients during the study period. Their mean age was 52.5 ± 12 years and 42.5% were female. Pancreatic masses were the most common lesions (37.7% followed by lymph nodes (36.9%. Submucosal lesions (17.7% and liver lesions (7.7% accounted for rest of the cases. The overall diagnostic yield for EUS-FNAC (70% and CB (74.6% was not significantly different (P = 0.3 and their combined yield was 85.3%. For the 23 patients with submucosal lesion, diagnostic yield of CB (82.6% was significantly better than cytology (47.8%, P = 0.04. Conclusions: EUS-guided CB has better yield compared to cytology in gastrointestinal submucosal lesions. The combination of CB with cytology improves the overall yield of the procedure; and hence, they should be considered complimentary rather than alternatives.

  19. Ultrasound-Guided Miniscalpel-Needle Release versus Dry Needling for Chronic Neck Pain: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Yongjun Zheng

    2014-01-01

    Full Text Available Objective. To compare ultrasound-guided miniscalpel-needle (UG-MSN release versus ultrasound-guided dry needling (UG-DN for chronic neck pain. Methods. A total of 169 patients with chronic neck pain were randomized to receive either UG-MSN release or UG-DN. Before treatment and at 3 and 6 months posttreatment, pain was measured using a 10-point visual analogue scale (VAS. Neck function was examined using the neck disability index. Health-related quality of life was examined using the physical component score (PCS and mental component score (MCS of the SF-36 health status scale. Results. Patients in the UG-MSN release had greater improvement on the VAS (by 2 points at 3 months and 0.9 points at 6 months versus in the UG-DN arm; (both P<0.0001. Patients receiving UG-MSN release also showed significantly lower scores on the adjusted neck disability index, as well as significantly lower PCS. No severe complications were observed. Conclusion. UG-MSN release was superior to UG-DN in reducing pain intensity and neck disability in patients with chronic neck pain and was not associated with severe complications. The procedural aspects in the two arms were identical; however, we did not verify the blinding success. As such, the results need to be interpreted with caution.

  20. Transbiliary intravascular ultrasound-guided diagnostic biopsy of an inaccessible pancreatic head mass

    Directory of Open Access Journals (Sweden)

    Jeffrey Forris Beecham Chick, MD, MPH, DABR

    2017-06-01

    Full Text Available Percutaneous image-guided biopsies of pancreatic malignancies may prove challenging and nondiagnostic due to a variety of anatomic considerations. For patients with complex post-surgical anatomy, such as a Roux-en-Y gastric bypass, diagnosis via endoscopic ultrasound with fine-needle aspiration may not be possible because of an inability to reach the proximal duodenum. This report describes the first diagnostic case of transbiliary intravascular ultrasound-guided biopsy of a pancreatic head mass in a patient with prior Roux-en-Y gastric bypass for which a diagnosis could not be achieved via percutaneous and endoscopic approaches. Transbiliary intravascular ultrasound-guided biopsy resulted in a diagnosis of pancreatic adenocarcinoma, allowing the initiation of chemotherapy.

  1. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    2016-07-27

    Jul 27, 2016 ... The different types of non-surgical breast biopsy procedures include: fine needle aspiration biopsy. (FNAB), core needle ... needle biopsies of breast lesions at a regional public hospital in ..... NCR_2009_FINAL.pdf. 2. Parikh J ...

  2. Lean Six Sigma Applied to Ultrasound Guided Needle Biopsy in the Head and Neck.

    Science.gov (United States)

    Matt, Bruce H; Woodward-Hagg, Heather K; Wade, Christopher L; Butler, Penny D; Kokoska, Mimi S

    2014-07-01

    (1) Confirm the positive value stream of office-based ultrasound using Lean Six Sigma; (2) demonstrate how ultrasound reduces time to diagnosis, costs, patient inconvenience and travel, exposure to ionizing radiation, intravenous contrast, and laboratory tests. Case series with historical controls using chart review. Tertiary Veterans Administration Hospital (university-affiliated). Patients with a consult request or decision for ultrasound guided fine needle aspiration (USFNA) from 2006 to 2012. Process evaluation using Lean Six Sigma methodologies; years study conducted: 2006-2012; outcome measurements: type of diagnostic tests and imaging studies including CT scans with associated radiation exposure, time to preliminary and final cytopathologic diagnosis, episodes of patient travel. Value stream mapping prior to and after implementing office-based ultrasound confirmed the time from consult request or decision for USFNA to completion of the USFNA was reduced from a range of 0 to 286 days requiring a maximum 17 steps to a range of 0 to 48 days, necessitating only a maximum of 9 steps. Office-based USFNA for evaluation of head and neck lesions reduced costs, time to diagnosis, risks and inconvenience to patients, radiation exposure, unnecessary laboratory, and patient complaints while increasing staff satisfaction. In addition, office-based ultrasound also changed the clinical management of specific patients. Lean Six Sigma reduces waste and optimizes quality and accuracy in manufacturing. This is the first known application of Lean Six Sigma to office-based USFNA in the evaluation of head and neck lesions. The literature supports the value of office-based ultrasound to patients and health care systems. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  3. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    Science.gov (United States)

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  4. Diagnostic efficacy of ultrasound-guided core-needle biopsy of peripheral lymph nodes in sarcoidosis.

    Science.gov (United States)

    Boussouar, S; Medjhoul, A; Bernaudin, J F; Tayebjee, O; Soussan, M; Uzunhan, Y; Nunes, H; Kambouchner, M; Martin, A; Valeyre, D; Brillet, P Y

    2015-09-14

    Core-needle biopsy guided by ultrasound can be performed for investigating peripheral lymph node (PLN). The aim of this study was to determine the efficacy of this technique in sarcoidosis. Retrospective review of files of all patients in the database of the radiology department of Avicenne university hospital who underwent PLN biopsies guided by ultrasound from January 2008 to June 2011 (n=292). Cases with either granulomas at histology with the procedure or with a final diagnosis of sarcoidosis were included in the study. The histological specimens were adequate in 282 out of 292 cases (96%) showing non-caseating granulomas in 22 cases (n=20 patients with a final diagnosis of sarcoidosis and n=2 patients with tuberculosis). After reviewing clinical files of the 282 patient, 22 were confirmed to have sarcoidosis, at initial presentation (n=19) or later during flare-up or relapse (n=3) with only 2 patients having no granuloma on PLN biopsy. PLN were palpable in 18 cases and only detected by (18F)FDG-PET/CT showing increased PLN uptake in 4 cases. The sensitivity and specificity of adequate biopsy were 91 and 99% and the positive and negative predictive values were 91 and 99%, respectively. Core-needle biopsy guided by ultrasound has a high efficacy for evidencing granulomas in sarcoidosis patients with PLN involvement either clinically palpable or in the presence of (18F)FDG-PET/CT uptake.

  5. MLESAC Based Localization of Needle Insertion Using 2D Ultrasound Images

    Science.gov (United States)

    Xu, Fei; Gao, Dedong; Wang, Shan; Zhanwen, A.

    2018-04-01

    In the 2D ultrasound image of ultrasound-guided percutaneous needle insertions, it is difficult to determine the positions of needle axis and tip because of the existence of artifacts and other noises. In this work the speckle is regarded as the noise of an ultrasound image, and a novel algorithm is presented to detect the needle in a 2D ultrasound image. Firstly, the wavelet soft thresholding technique based on BayesShrink rule is used to denoise the speckle of ultrasound image. Secondly, we add Otsu’s thresholding method and morphologic operations to pre-process the ultrasound image. Finally, the localization of the needle is identified and positioned in the 2D ultrasound image based on the maximum likelihood estimation sample consensus (MLESAC) algorithm. The experimental results show that it is valid for estimating the position of needle axis and tip in the ultrasound images with the proposed algorithm. The research work is hopeful to be used in the path planning and robot-assisted needle insertion procedures.

  6. About the diagnostic accuracy rate of fluoroscopy-guided fine needle puncture

    International Nuclear Information System (INIS)

    Wernecke, K.; Teske, H.J.

    1983-01-01

    Percutaneous fine-needle biopsies guided by X-ray were performed in 100 patients utilizing the Nordenstroem canule. All cases have now been clinically controlled for at least 14 and up to 30 months. The follow up allowed further conclusions due to the dignity of histologically negative biopsies. Positive results on malignant lesions were obtained in 74% of cases. Our experience revealed that negative aspiration biopsies should be considered false negative until they could be confirmed by further investigations. (orig.) [de

  7. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    Energy Technology Data Exchange (ETDEWEB)

    Tantawy, Wahid H., E-mail: tantawyw@yahoo.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); El-Gemeie, Emad H. [Pathology Department, National Cancer Institute, Fom El Khalige Faculty of Medicine, Cairo University (Egypt); Ibrahim, Ahmed S., E-mail: asibrahima@gmail.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); Mohamed, Mona A. [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt)

    2012-10-15

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening.

  8. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    International Nuclear Information System (INIS)

    Tantawy, Wahid H.; El-Gemeie, Emad H.; Ibrahim, Ahmed S.; Mohamed, Mona A.

    2012-01-01

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening

  9. Imprint cytology from ultrasound-guided core biopsies: accurate and immediate diagnosis in a one-stop breast clinic

    International Nuclear Information System (INIS)

    Jones, L.; Lott, M.F.; Calder, C.J.; Kutt, E.

    2004-01-01

    AIM: To investigate whether imprint cytology from ultrasound-guided core biopsy specimens was adequate for the National Health Service Breast Screening Programme (NHSBSP) guidelines. METHODS: We prospectively audited imprint cytology from ultrasound-guided core biopsy specimens. The performance indicators for imprint cytology specimens from 111 consecutive ultrasound-guided core biopsy were compared with standards set by the NHSBSP for fine-needle aspiration cytology (FNAC). RESULTS: Imprint cytology fulfilled the 'preferred' targets for absolute and complete sensitivity, specificity, positive predictive value, false-positive and false-negative rates, inadequate rate and inadequate rate from cancers. It also satisfied the minimum target for suspicious rate. The complete sensitivity was 97%, full specificity 78%, with 100% positive predictive value for C5 cytology and an inadequate rate from cancers of 1.5%. CONCLUSION: Imprint cytology from ultrasound-guided core biopsy allows same-day diagnosis and the collection of data regarding the grade of the carcinoma for treatment decisions from a single needle test

  10. Endobronchial Ultrasound-guided Transbronchial Needle Injection of Liposomal Amphotericin B for the Treatment of Symptomatic Aspergilloma.

    Science.gov (United States)

    Parikh, Mihir S; Seeley, Eric; Nguyen-Tran, Evelyn; Krishna, Ganesh

    2017-10-01

    Surgical treatment with lung resection has traditionally been the treatment of choice for pulmonary cavities containing aspergillomas that cause hemoptysis. Endobronchial ultrasound (EBUS) is a minimally invasive bronchoscopic technique that is commonly used for transbronchial needle aspiration of hilar and mediastinal lymph nodes as well as centrally located parenchymal lesions. Here, we describe a case of a 71-year-old woman who was found to have a cavitary lesion in the lung containing aspergillomas. Under direct ultrasound visualization with EBUS, liposomal amphotericin B was injected into the aspergillomas. These aspergillomas regressed after treatment. To our knowledge, this is the first reported treatment of aspergilloma with EBUS-guided transbronchial needle injection of liposomal amphotericin B.

  11. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice

    NARCIS (Netherlands)

    Scholten, H.J.; Pourtaherian, A.; Mihajlovic, N.; Korsten, H.; Bouwman, R.A.

    2017-01-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging

  12. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    Science.gov (United States)

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (Ptennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  13. CT guided fine needle aspiration biopsy of biliopancreatic lesions

    International Nuclear Information System (INIS)

    Geng, Jia-Zheng; Qin, Pan-Rui; Hui, Liu-De; Po, Pei-Dong

    1987-01-01

    CT guided percutaneous fine needle aspiration biopsy was performed on 30 patients with pancreatic and periampullary neoplasms, in the Department of Surgery, China-Japan Friendship Hospital, between March 1985 and January 1986. We obtained positive cytodiagnosis from all cases of carcinoma of the pancreatic head (9 cases), body and tail (4 cases), and ampullary carcinomas (5 cases) (100 per cent). In 2 of 3 duodenal carcinomas (66.6 per cent), and 6 of 7 distal common duct carcinomas (86 per cent), a positive cytodiagnosis was also obtained. On the other hand, 2 cases of pancreatitis both gave a negative cytodiagnosis, i.e. no false positives were obtained. Out of the 30 cases who underwent CT guided biopsy, a correct diagnosis was obtained in 28, i.e. a diagnostic accuracy of 93.3 per cent. The cytodiagnosis of the other two cases was either suspicious or false negative. There have been no clinical complications noted. (author)

  14. Comparison of a GPS needle-tracking system, multiplanar imaging and 2D imaging for real-time ultrasound-guided epidural anaesthesia: A randomized, comparative, observer-blinded study on phantoms.

    Science.gov (United States)

    Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier

    2017-04-01

    The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  15. An ultrasound-driven needle-insertion robot for percutaneous cholecystostomy

    International Nuclear Information System (INIS)

    Hong, J; Dohi, T; Hashizume, M; Konishi, K; Hata, N

    2004-01-01

    A real-time ultrasound-guided needle-insertion medical robot for percutaneous cholecystostomy has been developed. Image-guided interventions have become widely accepted because they are consistent with minimal invasiveness. However, organ or abnormality displacement due to involuntary patient motion may undesirably affect the intervention. The proposed instrument uses intraoperative images and modifies the needle path in real time by using a novel ultrasonic image segmentation technique. In phantom and volunteer experiments, the needle path updating time was 130 and 301 ms per cycle, respectively. In animal experiments, the needle could be placed accurately in the target

  16. Fibroadenoma: can fine needle aspiration biopsy avoid short term follow-up?

    Science.gov (United States)

    Leconte, I; Abraham, C; Galant, C; Sy, M; Berlière, M; Fellah, L

    2012-10-01

    To confirm whether fine needle aspiration biopsy (FNAB) can avoid close monitoring, a source of worry for women patients with a suspected fibroadenoma found by ultrasound, and requiring their compliance. Over 39months, 427 nodules with a diagnosis of fibroadenoma were sampled in 372 patients using ultrasound-guided FNAB. The sonographic appearance of all the nodules suggested BI-RADS category 3 fibroadenomas. The mean size of the fibroadenomas was 9mm. The mean duration of follow-up was 29.7months. Seven nodules had atypical cytology: a microbiopsy and/or excision found a simple fibroadenoma (n=3), mastitis (n=1), a fibroadenoma associated with a papilloma (n=1), fibrosis (n=1) and normal tissue (n=1). Seven other nodules were resected during treatment for synchronous cancer, and were diagnosed as fibroadenomas. Two hundred and seventy-six nodules were followed-up (121 patients were lost to follow-up [n=132]) and the appearance of 263 nodules (95.29%) was stable. Seven nodules, which had increased in size, underwent another FNAB or microbiopsy or surgery. Five nodules were not found again. The borders of one nodule showed modifications. The use of fine needle aspiration biopsy, interpreted by an experienced cytologist, means that short term follow-up of fibroadenomas can be avoided. Copyright © 2012 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  17. Safety and correlation of test results of combined ultrasound-guided fine-needle aspiration and needle core biopsy of the canine spleen.

    Science.gov (United States)

    Watson, Adam T; Penninck, Dominique; Knoll, Joyce S; Keating, John H; Sutherland-Smith, James

    2011-01-01

    The safety and diagnostic value of combined splenic fine-needle aspiration (FNA) and needle core biopsy (NCB) is unknown. Forty-one dogs with splenic lesions were studied prospectively. Safety was assessed in 38 dogs and no complications were encountered. Initially, clinical and anatomic pathologists reviewed each FNA and NCB sample, respectively, without knowledge of the other's results. Diagnoses were categorized as neoplastic, benign, inflammatory, normal, or nondiagnostic. The level of agreement between sampling methods was categorized as complete, partial, disagreement, or not available. Test correlation was performed in 40 dogs. Nondiagnostic results occurred in 5/40 NCB (12.5%) and no FNA samples. Neoplasia was diagnosed in 17/40 dogs (42.5%), benign changes in 20/40 dogs (50%), inflammatory disorders in 0/40 dogs, and normal 2/40 dogs (5%). One of the 40 dogs (2.5%) had a diagnosis that was equivocal for neoplasia on both tests and therefore was not categorized. Of the 35 dogs that had diagnostic samples, cytopathologic and histopathologic diagnoses agreed completely in 18/35 dogs (51.4%), partially in 3/35 dogs (8.6%), and were in disagreement in 14/35 dogs (40.0%). Pathologists collaboratively reviewed diagnoses that were in disagreement or partial agreement and altered their individual diagnoses in 6/17 dogs (35.3%) to be within partial or complete agreement, respectively. Percutaneous FNA and NCB can be performed safely in dogs with sonographic splenic changes. Results suggest that adding NCB to FNA provides complementary information in dogs with suspected splenic neoplasia. This combined protocol may improve detection of splenic neoplasia and provide neoplastic subclassification. © 2010 Veterinary Radiology & Ultrasound.

  18. Guided fine needle aspiration cytology of retroperitoneal masses - Our experience

    Directory of Open Access Journals (Sweden)

    Mimi Gangopadhyay

    2011-01-01

    Full Text Available Background : Early pathological classification of retroperitoneal masses is important for pin-point diagnosis and timely management. Aims : This study was done to evaluate the usefulness and drawbacks of guided fine needle aspiration cytology (FNAC of retroperitoneal masses covering a period of two years with an intention to distinguish between neoplastic and non-neoplastic lesions and to correlate with histologic findings. Materials and Methods : FNAC was done under radiological guidance in all cases using long needle fitted with disposable syringe. Appropriate staining was done and cytology was correlated with histology which was taken as the gold standard for comparison. Results : Fifty-one patients who presented with retroperitoneal masses were studied. Forty-four lesions were malignant cytologically and 7 were inflammatory (tuberculous. According to radiological and cytologic findings, we classified our cases into four groups: renal tumors, retroperitoneal lymphadenopathy, germ cell tumors, soft tissue tumors. Except for cases of non-Hodgkin lymphoma (NHL and metastatic lesions, we had sensitivity and specificity of 100%. In NHL the sensitivity and specificity were both 50%. In cases of metastatic adenocarcinoma, the sensitivity and specificity were 84.6% and 81.8%, respectively. Conclusions : Ignoring the pitfalls, guided FNAC is still an inexpensive and reliable method of early diagnosis of retroperitoneal lesions.

  19. Cytological Results of Ultrasound-Guided Fine-Needle Aspiration Cytology for Thyroid Nodules: Emphasis on Correlation with Sonographic Findings

    Science.gov (United States)

    Lee, Mi-Jung; Hong, Soon Won; Chung, Woung Youn; Kwak, Jin Young; Kim, Min Jung

    2011-01-01

    Purpose To compare the cytological results of ultrasound-guided fine-needle aspiration (US-FNA) cytology of thyroid nodules to sonographic findings and determine whether US findings are helpful in the interpretation of cytological results. Materials and Methods Among the thyroid nodules that underwent US-FNA cytology, we included the 819 nodules which had a conclusive diagnosis. Final diagnosis was based on pathology from surgery, repeated FNA cytology or follow-up of more than one year. Cytological results were divided into five groups: benign, indeterminate (follicular or Hurthle cell neoplasm), suspicious for malignancy, malignant, and inadequate. US findings were categorized as benign or suspicious. Cytological results and US categories were analyzed. Results Final diagnosis was concluded upon in 819 nodules based on pathology (n=311), repeated FNA cytology (n=204) and follow-up (n=304), of which 634 were benign and 185 were malignant. There were 560 benign nodules, 141 malignant nodules, 49 nodules with inadequate results, 21 with indeterminate results, and 48 that were suspicious for malignancy. The positive and negative predictive values of the US categories were 59.1% and 97.0%, and those of the cytological results were 93.7% and 98.9%. The US categories were significantly correlated with final diagnosis in the benign (p=0.014) and suspicious for malignancy (pcytological result groups, but not in the inadequate and indeterminate cytological results groups. The false positive and negative rates of cytological results were 1.9% and 3.2%. Conclusion Sonographic findings can be useful when used alongside cytological results, especially in nodules with cytological results that are benign or suspicious for malignancy. PMID:21786450

  20. Diagnostic accuracy of percutaneous cytodiagnosis of hepatic masses, by ultrasound guided fine needle aspiration cytology

    International Nuclear Information System (INIS)

    Asghar, F.; Riaz, S.

    2010-01-01

    Objective: To evaluate the diagnostic accuracy, usefulness and limitations of ultrasound guided FNAC of hepatic masses. Design: Cross - sectional analytical (comparative study). Place and Duration: Department of histopathology, Sheikh Zayed Hospital, Lahore. Study period 1 year. Material and Methods: A total of 32 patients with solitary or multiple hepatic masses underwent FNAC from March 1999 to March 2000. Adequate aspirates were obtained in all these cases. Smears were stained with May-Grunwald Giemsa, Haematoxylin and Eosin and Papanicolaou stain. Needle biopsies from the same cases were also obtained and processed. These were stained with routine Haematoxylin and Eosin staining. The blood clots obtained during FNAC were fixed in 10% neu-tral buffered formalin. The histopathology of these blood clots was used for cases whose needle core biopsy was not available. The screened FNAC smears were divided into 3 categories i.e., benign (group - I), malignant (group - II), non-neoplastic / inflammatory lesions (including cysts and abscesses) (group - III). Results: Out of 32 cases, 6 were categorized as benign, 18 as malignant, and 8 as non-neoplastic inflammatory lesions. Three false negative diagnoses, including 1 for malignant tumour and 2 for benign tumours was obtained. There was 1 false positive diagnosis for malignancy. FNAC - histological correlation showed a 94.2% sensitivity and 92.3% diagnostic accuracy for malignant tumours, while benign tumours posed maximum diagnostic problems, giving a 66.67% sensitivity and 85.7% diagnostic accuracy. FNAC picked up correctly all the non-neoplastic lesions giving a 100% sensitivity and diagnostic accuracy. Conclusion: Majority of the malignant tumours can be categorized on FNAC, with a high degree of accuracy, while benign tumours should be subjected to biopsy, as there is a relatively greater possibility of false negative diagnosis. (author)

  1. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    Science.gov (United States)

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  2. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  3. A Case of Bilateral Acute Calcific Tendinitis of the Gluteus Medius, Treated by Ultrasound-guided Needle Lavage and Corticosteroid Injection

    OpenAIRE

    Vereecke, Elke; Mermuys, Koen; Casselman, Jan

    2015-01-01

    Calcium hydroxyapatite deposition disease is a common pathology, most frequently located in the rotator cuff tendons of the shoulder, for which different therapeutic approaches are used. Ultrasound guided needle lavage and injection of anesthetic/corticosteroid is a well-known and extensively described treatment for calcific tendinits of the rotator cuff. We present a case of bilateral calcific tendinitis of the gluteus medius tendon, both sides successfully treated using ultrasound guided ne...

  4. Results and complications of CT-guided transthoracic fine-needle aspiration biopsy of pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Cristiano Dias de; Nunes, Rodolfo Acatauassu; Saito, Eduardo Haruo; Higa, Claudio; Cardona, Zanier Jose Fernando; Santos, Denise Barbosa dos, E-mail: cristianodiaslima@gmail.co [Hospital Universitario Pedro Ernesto (HUPE/UERJ), Rio de Janeiro, RJ (Brazil). Dept. Cirurgia Toracica

    2011-03-15

    Objective: to analyze the cytological findings of CT-guided percutaneous fine-needle aspiration biopsies of the lung, to demonstrate the diagnostic feasibility of the method in the investigation of pulmonary lesions, and to determine the complications of the procedure, evaluating its safety. Methods: a retrospective analysis of 89 patients with various types of pulmonary lesions who underwent 97 procedures over a period of five years. The patients were divided into groups regarding the indication for the procedure: suspicion of primary lung cancer (stages IIIB or IV); suspicion of lung cancer (stages I, II, or IIIA) and clinical contraindications for surgery; suspicion of pulmonary metastasis from other organs; and pulmonary lesions with benign radiological aspect. All of the procedures were performed with 25-gauge needles and were guided by spiral CT. The final diagnosis was confirmed by surgical biopsy and clinical/oncological follow-up. For the analysis of complications, the total number of procedures was considered. Results: the main indication for the procedure was suspicion of advanced stage primary lung cancer. The accuracy of the method for malignant lesions was 91.5%. The lesion was confirmed as cancer in 73% of the patients. The major complication was pneumothorax (27.8%), which required chest tube drainage in 12.4% of the procedures. Conclusions: the principal indication for CT-guided fine-needle biopsy was suspicion of primary lung cancer in patients who were not surgical candidates. The procedure has high diagnostic feasibility for malignant pulmonary diseases. The most prevalent complication was pneumothorax. However, in most cases, chest tube drainage was unnecessary. No deaths were related to the procedure. (author)

  5. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    2011-06-15

    Jun 15, 2011 ... guided PFNAB/US-guided PNCB was the diagnostic test in 23.33% cases. It confirmed a highly ..... provides guidance in multiple axial, longitudinal and .... Source of Support: Nil, Con.ict of Interest: None declared. Gani, et al.

  6. Computed tomography guided needle biopsy: experience from 1,300 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Isberner, Rony Klaus; Viana, Luciana Marinho; Yu, Liao Shin; Aita, Alessandro Amorim; Soares, Fernando Augusto [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radiologia e Patologia

    2006-01-15

    Context and objective: computed tomography (CT) guided biopsy is widely accepted as effective and safe for diagnosis in many settings. Accuracy depends on target organ and needle type. Cutting needles present advantages over fine needles. This study presents experience from CT guided biopsies performed at an oncology center. Design and setting: retrospective study at Hospital do Cancer A. C. Camargo, Sao Paulo.Methods: 1,300 consecutive CT guided biopsies performed between July 1994 and February 2000 were analyzed. Nodules or masses were suspected as primary malignancy in 845 cases (65%) or metastatic lesion in 455 (35%). 628 lesions were thoracic, 281 abdominal, 208 retroperitoneal, 134 musculoskeletal and 49 head/neck. All biopsies were performed by one radiologist or under his supervision: 765 (59%) with 22-gauge fine-needle/aspiration technique and 535 (41%) with automated 16 or 18-gauge cutting-needle biopsy. Results: adequate samples were obtained in 70-92% of fine-needle and 93-100% of cutting-needle biopsies. The specific diagnosis rates were 54-67% for fine-needle and 82-100% for cutting-needle biopsies, according to biopsy site. For any site, sample adequacy and specific diagnosis rate were always better for cutting-needle biopsy. Among 530 lung biopsies, there were 84 pneumothorax (16%) and two hemothorax (0.3%) cases, with thoracic drainage in 24 (4.9%). Among abdominal and retroperitoneal biopsies, there were two cases of major bleeding and one of peritonitis. Conclusion: both types of needle showed satisfactory results, but cutting-needle biopsy should be used when specific diagnosis is desired without greater incidence of complications. (author)

  7. Imaging-guided and nonimaging-guided fine needle aspiration of liver lesions: experience with 406 patients.

    Science.gov (United States)

    Edoute, Y; Tibon-Fisher, O; Ben-Haim, S A; Malberger, E

    1991-12-01

    The aim of the present study was to determine the diagnostic accuracy of different modes of fine needle aspiration (FNA) of liver lesions. A total of 492 FNAs were performed on 406 patients in order to confirm or to rule out focal or multifocal neoplastic disease: 29% under ultrasound (US) guidance, 3% with computed tomographic (CT) guidance, 67% preoperatively, and 1% intraoperatively without imaging guidance. Based on histologic, cytologic, and clinical findings, final diagnoses were reached in 387 patients, of whom 264 had malignant liver disease and 123 had benign liver disease. Of 321 aspirations performed in patients with malignant liver disease, the cytologic findings suggested malignancy in 225 (70.1%), suspected malignancy in 25 (7.8%), and did not reveal malignancy in 71 aspirations (22.1%). Among the 123 patients with benign liver disease, the cytologic findings were reported as benign in all but two patients, who had false-positive cytologic findings. The overall sensitivity, specificity, positive, and negative predictive values for cytologic findings were 85.6, 98.4, 99.1, and 76.1%, respectively. The overall diagnostic accuracy was 89.7%. In one patient, fatal intraperitoneal bleeding due to chronic intravascular coagulation complicated the FNA procedure. We conclude that imaging-guided FNA as well as nonguided FNA for cytologic diagnosis of liver lesions are highly accurate and only rarely may be associated with a fatal complication.

  8. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  9. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  10. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    Science.gov (United States)

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions  .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Me [Dankook University Hospital, Seoul (Korea, Republic of); Park, Hee Boong [Park Breast Clinic, Seoul (Korea, Republic of); Ryu, Jin Woo [Cheonan Choongmu Hospital, Cheonan (Korea, Republic of)

    2005-08-15

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images.

  12. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    International Nuclear Information System (INIS)

    Kim, You Me; Park, Hee Boong; Ryu, Jin Woo

    2005-01-01

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images

  13. Detection of suspicious malignant cervical lymph nodes of unknown origin: diagnostic accuracy of ultrasound-guided fine-needle aspiration biopsy with nodal size and central necrosis correlate

    International Nuclear Information System (INIS)

    Lo, C.-P.; Chen, C.-Y.; Chin, S-.C.; Lee, K.-W.; Hsueh, C.-J.; Juan, C.-J.; Kao, H.-W.; Huang, G.-S.

    2007-01-01

    To assess the role of ultrasound-guided fine-needle aspiration biopsy (US-guided FNAB) in the diagnostic workup of suspicious malignant cervical lymph nodes in patients with palpable neck masses and without known primary cancer. The diagnostic accuracy of imaging morphologic criteria, including sizes and central necrosis for assessing suspicious malignant nodes, were also examined. This is a retrospective study of 426 patients with palpable neck masses from an outpatient department evaluated with computed tomography, magnetic resonance imaging, or US. US-guided FNABs were performed in 102 patients with suspicious malignant cervical lymph nodes at a single institution. Cytologically positive lymph nodes (n = 12) were further validated with excisional biopsy. Negative lymph nodes (n = 90) were either excised (n = 10) or followed up by imaging studies for at least one year (n = 80). The diagnostic accuracy of the FNABs along with the imaging findings of nodal sizes and presence of central necrosis, which were classified by a consensus of 2 radiologists, were assessed. Twelve malignant nodes were detected with US-guided FNAB with one false-positive and one false-negative result. The overall sensitivity, specificity, and accuracy for FNAB were 91.7%, 98.9%, and 98.0%. respectively. The sensitivity, specificity, and accuracy were 66.7%, 30.0%, and 34.3% for size criterion and 75.0%, 83.3%, and 82.3% for central necrosis criterion. The size of cervical lymph node does not appear to be an important imaging criterion for assessing suspicious malignant lymph nodes, compared with the criterion of central necrosis. US-guided FNAB is highly specific and sensitive in the diagnostic workup of suspicious malignant cervical lymph nodes in patients without known primary cancers. (author)

  14. Preoperative US-guided hook-needle insertion in recurrent lymph nodes of papillary thyroid cancer: A help for the surgeon

    International Nuclear Information System (INIS)

    Duprez, Raphaelle; Lebas, Patrick; Marc, Olivier Saint; Mongeois, Elise; Emy, Philippe; Michenet, Patrick

    2010-01-01

    Objective: The objective of this study is to investigate whether preoperative ultrasound guided insertion of a hook-needle is useful in reoperations for cervical recurrent lymph node metastases of papillary thyroid cancer. Patients and methods: 8 patients with operated papillary thyroid cancer were included in this study. They all had suspicious nonpalpable cervical lymph nodes discovered during follow-up. These lymph nodes were identified by ultrasound imaging and their metastatic nature was confirmed by fine needle aspiration cytology and measurement of in situ thyroglobulin. In all cases, surgical excision of these lymph nodes was decided. All 8 patients had a hook-needle inserted in the suspicious lymph node(s) preoperatively and under ultrasound guidance. Results and conclusion: In all 8 patients, the suspicious lymph nodes were removed and their metastatic nature was confirmed by the final pathological examination. This localization technique is very helpful for the surgeon during the excision of small and nonpalpable lymph nodes, especially in previously operated area.

  15. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material

    International Nuclear Information System (INIS)

    Degirmenci, B.; Haktanir, A.; Albayrak, R.; Acar, M.; Sahin, D.A.; Sahin, O.; Yucel, A.; Caliskan, G.

    2007-01-01

    Aim: To evaluate the effects of sonographic characteristics of thyroid nodules, the diameter of needle used for sampling, and sampling technique on obtaining sufficient cytological material (SCM). Materials and methods: We performed sonography-guided fine-needle biopsy (FNB) in 232 solid thyroid nodules. Size-, echogenicity, vascularity, and localization of all nodules were evaluated by Doppler sonography before the biopsy. Needles of size 20, 22, and 24 G were used for biopsy. The biopsy specimen was acquired using two different methods after localisation. In first method, the needle tip was advanced into the nodule in various positions using a to-and-fro motion whilst in the nodule, along with concurrent aspiration. In the second method, the needle was advanced vigorously using a to-and-fro motion within the nodule whilst being rotated on its axis (capillary-action technique). Results: The mean nodule size was 2.1 ± 1.3 cm (range 0.4-7.2 cm). SCM was acquired from 154 (66.4%) nodules by sonography-guided FNB. In 78 (33.6%) nodules, SCM could not be collected. There was no significant difference between nodules with different echogenicity and vascularity for SCM. Regarding the needle size, the lowest rate of SCM was obtained using 20 G needles (56.6%) and the highest rate of adequate material was obtained using 24 G needles (82.5%; p = 0.001). The SCM rate was 76.9% with the capillary-action technique versus 49.4% with the aspiration technique (p < 0.001). Conclusion: Selecting finer needles (24-25 G) for sonography-guided FNB of thyroid nodules and using the capillary-action technique decreased the rate of inadequate material in cytological examination

  16. Thyroid Fine-Needle Aspiration under Ultrasound Guidance: Experience from an Academic Tertiary Care Center in Lebanon

    Directory of Open Access Journals (Sweden)

    Rita Hajj Boutros

    2017-07-01

    Full Text Available Thyroid nodules are common. Malignancy was reported in only 5-15% of cases. Fine needle aspiration under US guidance (USG-FNA proved to be accurate for the detection of thyroid cancer. This is a retrospective review of 400 radiology and cytology USG-FNA reports, randomly selected among those done at the Radiology Department at a tertiary care center in Beirut during the last five years. The specimen was inadequate in 60 (12% of cases but FNA was repeated in 10 cases only. The final diagnosis was benign in 76.7% of cases, mostly in women. 35% of the malignant and 19% of the benign nodules were hypoechoic, p=0.03. No significant correlation was observed between malignancy and other ultrasonic characteristics. Hypoechogenecity was also more common in nodules with inadequate specimen (40% versus 21.4%, p=0.01. Age, gender, location and size of the nodule did not differ between groups of adequate and inadequate specimen. In conclusion, 3 out of 4 thyroid nodules referred for USG-FNA are benign, mostly in women. Inadequate specimen was observed in 12% of cases. Hypoechogenecity but not other ultrasonic characteristics was associated with malignancy and with test failure.   Key words: Thyroid nodule, fine needle aspirate, ultrasound guidance, thyroid cancer, inadequate.

  17. Robotic Needle Guide for Prostate Brachytherapy: Clinical Testing of Feasibility and Performance

    Science.gov (United States)

    Song, Danny Y; Burdette, Everette C; Fiene, Jonathan; Armour, Elwood; Kronreif, Gernot; Deguet, Anton; Zhang, Zhe; Iordachita, Iulian; Fichtinger, Gabor; Kazanzides, Peter

    2010-01-01

    Purpose Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide towards the goal of allowing greater freedom of needle placement. Methods and Materials The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40mm are possible. Needle insertion is performed manually. Results Five patients were treated in an IRB-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (SD 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54/179 (30.2%) needles placed, with 36/179 (20.1%) adjustments of > 2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. Conclusions Robotic needle positioning provided a means of compensating for needle deflections as well as the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting. PMID:20729152

  18. Surgeon-Performed Ultrasound-Guided Fine-Needle Aspiration Cytology (SP-US-FNAC) Shortens Time for Diagnosis of Thyroid Nodules.

    Science.gov (United States)

    Gu, Wei Xiang; Tan, Chuen Seng; Ho, Thomas W T

    2014-06-01

    Ultrasound-guided fine-needle aspiration cytology (US-FNAC) of thyroid nodules is an important diagnostic procedure. In most hospitals, patients are referred to radiologists for US-FNAC, but this often results in a long waiting time before results are available. Surgeon-performed US-FNAC (SP-US-FNAC) during the initial patient consultation attempts to reduce the waiting time but it is not known whether this is as accurate as radiologist-performed US-FNAC (RP-US-FNAC). The aim of this study is to compare the clinical efficiency between SP-US-FNAC and RP-US-FNAC. A retrospective study was performed on patients from the Department of General Surgery, Tan Tock Seng Hospital (TTSH) who underwent an US-FNAC from August 2011 to May 2012. All cases of SP-US-FNAC were performed by a single surgeon. This study compared the rates of positive diagnoses achieved by SP-US-FNAC and RPUS- FNAC as well as the time interval to reach a cytological diagnosis by each group. A total of 40 cases of SP-US-FNAC and 72 cases of RP-US-FNAC were included in the study. SP-US-FNAC resulted in 28 (70%) positive diagnoses and 12 (30%) nondiagnoses while RP-US-FNAC resulted in 47 (65.3%) positive diagnoses and 25 (34.7%) non-diagnoses. These results were comparable (P=0.678). The median time taken to reach a cytological diagnosis was 1 working day for SP-US-FNAC and 29.5 working days for RP-US-FNAC resulting in a shorter interval to reaching a cytological diagnosis for SP-US-FNAC (P<0.001). In the workup of thyroid nodules, SP-US-FNAC is as accurate as RP-US-FNAC but significantly reduces the time taken to reach a cytological diagnosis. This leads to greater clinical efficiency in the management of patients with thyroid nodules, which in turn leads to other benefits such as decreased patient anxiety and increased patient satisfaction.

  19. Ultrasonography-Guided Fine Needle Aspiration Cytology of Cervical Lymphadenopathy: Comparative Study of the Cytological Adequacy Using of 21- and 23- Gauge Needles

    International Nuclear Information System (INIS)

    Beak, Jin Wook; KIm, Dong Wook; Kim, Bo Mi

    2011-01-01

    To assess the difference in the cytological adequacy of ultrasonography (US)-guided fine needle aspiration cytology (US-FNAC) for cervical lymphadenopathy using 21 and 23 gauge needles. US-FNACs were separately performed on two cervical lymph nodes and in each patient using 21 gauge (group A) and 23 gauge (group B) needles, respectively. We used 4 grade classifications for the cytological analysis of each slide and compared the cytological adequacy of US-FNAC for cervical lymphadenopathy in the two groups. We performed US-FNACs on 58 cervical lymph nodes from 29 patients, with a cytological adequacy of 69.0%. The number of adequate cytological results was 19 (65.5%) in group A and 21 (72.4%) in group B, and the diagnostic adequacy did not differ significantly between the two groups (Mann-Whitney test, p = 0.574). There was no statistically significant difference in the cytological adequacy of US-FNAC for cervical lymphadenopathy according using of 21 and 23 gauge needles.

  20. Diagnosis of Hepatocellular Carcinoma Complicating Liver Cirrhosis: Utility of Repeat Ultrasound-Guided Biopsy after Unsuccessful First Sampling

    International Nuclear Information System (INIS)

    Caturelli, Eugenio; Biasini, Elisabetta; Bartolucci, Francesca; Facciorusso, Domenico; Decembrino, Francesco; Attino, Vito; Bisceglia, Michele

    2002-01-01

    Purpose: To evaluate the utility of a second ultrasound-guided fine-needle biopsy of liver nodules thought to be hepatocellular carcinoma when the original biopsy has failed to provide a reliable diagnosis. Methods: Thirty-seven cirrhotic patients underwent ultrasound-guided fine-needle biopsy of liver nodules that were subsequently diagnosed as hepatocellular carcinoma. Each biopsy involved a single puncture with a 20 G cutting needle, which yielded pathologic material used both for cytologic and histologic studies. In 23 cases (mean diameter of nodules 48 mm) the biopsy furnished exclusively necrotic material (non-diagnostic subgroup); in the other 14 cases (mean diameter 26 mm) the biopsy yielded no neoplastic elements (false-negative subgroup). All 37 nodules were subjected to repeat biopsies performed in the same manner. Results: The repeat biopsies provided a diagnosis of hepatocellular carcinoma in six of the 23 patients from the non-diagnostic subgroup and in seven of the 14 in the false-negative subgroup. Overall, repeat biopsy produced a diagnostic gain of 35.1%. Conclusion: The chance of success with repeat biopsy of hepatocellular carcinoma is limited and may depend to some extent on the characteristics of the lesions (i.e., areas of necrosis in large nodules, well-differentiated cellular populations in small ones)

  1. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  2. Needle localization using a moving stylet/catheter in ultrasound-guided regional anesthesia: a feasibility study

    Science.gov (United States)

    Beigi, Parmida; Rohling, Robert

    2014-03-01

    Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.

  3. Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy in cavitary pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yi-Ping, E-mail: yipingzhuang2010@sina.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Wang, Hai-Yan, E-mail: mycherishgirl@sohu.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Zhang, Jin, E-mail: yari_zj@hotmail.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Feng, Yong, E-mail: fengyong119@sohu.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Zhang, Lei, E-mail: motozl163@163.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China)

    2013-01-15

    Objective: CT-guided transthoracic biopsy is a well-established method in the cytologic or histologic diagnosis of pulmonary lesions. The knowledge of its diagnostic performance and complications for cavitary pulmonary lesions is limited. The purpose of this study was to determine the diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy (FNAB) in cavitary pulmonary lesions. Materials and methods: 102 consecutive patients with pulmonary cavitary lesions received CT-guided FNAB with use of an 18-gauge (n = 35) or 20-gauge (n = 67) Chiba for histology diagnosis. The sensitivity, specificity, and diagnostic accuracy of FNAB were calculated as compared with the final diagnosis. Complications associated with FNAB were observed. The diagnostic accuracy and complications were compared between patients with different lesion sizes and different cavity wall thickness. Results: The overall sensitivity, specificity, and accuracy of FNAB were 96.3%, 98.0%, and 96.1%, respectively. The sensitivity, specificity, and diagnosis accuracy in different lesion size (<2 cm vs ≥2 cm), or different cavity wall thickness (<5 mm vs ≥5 mm) were not different (P > 0.05; 0.235). More nondiagnostic sample was found in wall thickness <5 mm lesions (P = 0.017). Associated complications included pneumothorax in 9 (8.8%) patients and alveolar hemorrhage in 14 patients (13.7%) and hemoptysis in 1 patient (1%). No different rate of complications was found with regard to lesion size, wall thickness, length of the needle path and needle size (P > 0.05). Conclusion: CT-guided FNAB can be effectively ad safely used for patients with pulmonary cavitary lesions.

  4. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    OpenAIRE

    Kang, Yun-Dan; Kim, You Me

    2015-01-01

    Purpose: The purpose of this study was to compare needle aspiration and vacuum-assistedbiopsy in the ultrasound-guided treatment of lactational breast abscesses. Methods: Between January 2005 and December 2014, a total of 74 patients presented withlactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated withneedle aspiration (n=25) or vacuum-assisted biopsy (n=19). Age, duration ...

  5. Diagnosis of invasive aspergillus tracheobronchitis facilitated by endobronchial ultrasound-guided transbronchial needle aspiration: a case report

    Directory of Open Access Journals (Sweden)

    Casal Roberto F

    2009-11-01

    Full Text Available Abstract Introduction Invasive pulmonary aspergillosis is the most common form of infection by Aspergillus species among immunocompromised patients. Although this infection frequently involves the lung parenchyma, it is unusual to find it limited to the tracheobronchial tree, a condition known as invasive aspergillus tracheobronchitis. Case presentation A 65 year-old Hispanic man from Bolivia with a history of chronic lymphocytic leukemia developed cough and malaise eight months after having an allogenic stem cell transplant. A computed tomography of the chest revealed an area of diffuse soft tissue thickening around the left main stem bronchus, which was intensely fluorodeoxyglucose-avid on positron emission tomography scanning. An initial bronchoscopic exam revealed circumferential narrowing of the entire left main stem bronchus with necrotic and friable material on the medial wall. Neither aspirates from this necrotic area nor bronchial washing were diagnostic. A second bronchoscopy with endobronchial ultrasound evidenced a soft tissue thickening on the medial aspect of the left main stem bronchus underlying the area of necrosis visible endoluminally. Endobronchial ultrasound-guided transbronchial needle aspiration performed in this area revealed multiple fungal elements suggestive of Aspergillus species. Conclusion We describe the first case of invasive aspergillus tracheobronchitis in which the diagnosis was facilitated by the use of endobronchial ultrasound guided trans-bronchial needle aspiration. To the best of our knowledge, we are also presenting the first positron emission tomography scan images of this condition in the literature. We cautiously suggest that endobronchial ultrasound imaging may be a useful tool to evaluate the degree of invasion and the involvement of vascular structures in these patients prior to bronchoscopic manipulation of the affected areas in an effort to avoid potentially fatal hemorrhage.

  6. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Wu [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada); Yuchi Ming; Ding Mingyue [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Tessier, David; Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5K8 (Canada)

    2013-04-15

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions

  7. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    International Nuclear Information System (INIS)

    Qiu Wu; Yuchi Ming; Ding Mingyue; Tessier, David; Fenster, Aaron

    2013-01-01

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 × 376 × 630 voxels. Conclusions: The proposed needle segmentation

  8. Role of Ultrasound Guided Biopsy of Thoracic Lesions | Elameen ...

    African Journals Online (AJOL)

    Objective: This prospective study is to evaluate and enhance the role of ultrasound in biopsy guidance of thoracic lesions. Methods: 55 patients were subjected for fine needle aspiration (FNA) and/or core needle biopsy (CNB) from peripheral chest lesions in Ribat University Hospital during the period from April 2011 and ...

  9. ULTRASONOGRAPHY AND COMPUTED TOMOGRAPHY GUIDED FINE NEEDLE ASPIRATION CYTOLOGY IN DIAGNOSING INTRA-ABDOMINAL LESIONS- A 6-YEAR RETROSPECTIVE STUDY IN A TERTIARY CARE HOSPITAL IN MANIPUR

    Directory of Open Access Journals (Sweden)

    Ratan Konjengbam

    2017-07-01

    Full Text Available BACKGROUND Fine-Needle Aspiration Cytology (FNAC is a widely used method, which is accurate and safe in a readily palpable masses. But, in those inaccessible lesions and deeper organs are safely aspirated using fine needle radiological procedure like ultrasound or computed tomography guided. The aim of the study is to assess the utility of FNAC in the diagnosis of intra-abdominal lesions and different pattern of lesions in particular to the sites. MATERIALS AND METHODS This retrospective study was done in the Department of Pathology, Regional Institute of Medical Sciences (RIMS, Imphal, between June 2010 and June 2016. The study included 128 intra-abdominal masses. Giemsa and Papanicolaou’s stains were used. The cytological diagnosis was correlated with clinical and radiological data to arrive at a final diagnosis. RESULTS Reports on FNAC smears were retrospectively analysed, which had been done in various anatomic sites- liver (70 cases, colon (19 cases, gallbladder (17 cases, mesenteric lymph nodes (12 cases, ovary (3 cases, adrenals (2 cases and 1 case each of pancreas, peritoneal wall, pelvic, suprapubic and flank masses. The mean age was 42.16 years with M:F of 1.3:1. The diagnostic yield was 85.2% in combination for Ultrasound Guided (USG and Computed Tomography (CT guided aspiration. The smears were classified as benign neoplastic, malignant neoplastic, non-neoplastic, inconclusive and unsatisfactory for interpretation. There were 79 (61.7% malignant neoplastic lesion, 5 (3.9% benign neoplastic lesion, 25 (19.5% non-neoplastic lesion, one (0.7% inconclusive lesions and 18 (14.1% unsatisfactory smears. The liver and the colon were the most common sites. Adenocarcinomas and Hepatocellular Carcinoma (HCC were the most common malignant lesions comprising of 35 (44.3% and 25 (31.6% of the total malignant lesions diagnosed. CONCLUSION Intra-abdominal FNA is a simple, economical and a safe procedure with high sensitivity, specificity and

  10. Prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy: A prospective multicenter study.

    Science.gov (United States)

    Chung, Ho Seok; Hwang, Eu Chang; Yu, Ho Song; Jung, Seung Il; Lee, Sun Ju; Lim, Dong Hoon; Cho, Won Jin; Choe, Hyun Sop; Lee, Seung-Ju; Park, Sung Woon

    2018-03-01

    To estimate the prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy and to identify the high-risk groups. From January 2015 to March 2016, rectal swabs of 557 men who underwent transrectal ultrasound-guided prostate needle biopsy were obtained from five institutions. Clinical variables, including demographics, rectal swab culture results and infectious complications, were evaluated. Univariable and multivariable analyses were used to identify the risk factors for fluoroquinolone resistance of rectal flora and infectious complications. The incidence of fluoroquinolone-resistant and extended-spectrum beta-lactamase production was 48.1 and 11.8%, respectively. The most common fluoroquinolone-resistant bacteria was Escherichia coli (81% of total fluoroquinolone-resistant bacteria, 39% of total rectal flora), and 16 (2.9%) patients had infectious complications. Univariable and multivariable analysis of clinical parameters affecting fluoroquinolone resistance showed no factor associated with fluoroquinolone resistance of rectal flora. The clinical parameter related to infectious complications after prostate biopsy was a history of operation within 6 months (relative risk 6.60; 95% confidence interval 1.99-21.8, P = 0.002). These findings suggest that a risk-based approach by history taking cannot predict antibiotic resistance of rectal flora, and physicians should consider targeted antibiotic prophylaxis or extended antibiotic prophylaxis for Korean patients undergoing transrectal ultrasound-guided prostate biopsy because of high antibiotic resistance of rectal flora. © 2017 The Japanese Urological Association.

  11. Value of Artisanal Simulators to Teach Ultrasound-Guided Percutaneous Biopsy Using a Tru-Cut Needle for Veterinary and Medical Students

    Science.gov (United States)

    de Araújo Setin, Raíza; Fortes Cirimbelli, Carolina; Mazeto Ercolin, Anna Carolina; Pires, Sâmara Turbay; Disselli, Tamiris; Ferrarini Nunes Soares Hage, Maria Cristina

    2018-01-01

    The present study aimed to evaluate the applicability of artisanal simulators to teach veterinary and medical students the ultrasound-guided percutaneous biopsy using a tru-cut needle. The artisanal simulators consisted of bovine liver between two layers of commercially available grape gelatin. Students were paired, with one doing the biopsy and…

  12. Endobronchial ultrasound-guided transbronchial needle aspiration for lung cancer staging: early experience in Brazil*,**

    Science.gov (United States)

    Figueiredo, Viviane Rossi; Cardoso, Paulo Francisco Guerreiro; Jacomelli, Márcia; Demarzo, Sérgio Eduardo; Palomino, Addy Lidvina Mejia; Rodrigues, Ascédio José; Terra, Ricardo Mingarini; Pego-Fernandes, Paulo Manoel; Carvalho, Carlos Roberto Ribeiro

    2015-01-01

    Objective: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. Methods: This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Results: Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67%) and squamous cell carcinoma (in 24%). For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. Conclusions: We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients. PMID:25750671

  13. Endobronchial ultrasound-guided transbronchial needle aspiration for lung cancer staging: early experience in Brazil,

    Directory of Open Access Journals (Sweden)

    Viviane Rossi Figueiredo

    2015-02-01

    Full Text Available Objective: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. Methods: This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Results: Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67% and squamous cell carcinoma (in 24%. For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. Conclusions: We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients.

  14. Endobronchial ultrasound-guided transbronchial needle aspiration for lung cancer staging: early experience in Brazil.

    Science.gov (United States)

    Figueiredo, Viviane Rossi; Cardoso, Paulo Francisco Guerreiro; Jacomelli, Márcia; Demarzo, Sérgio Eduardo; Palomino, Addy Lidvina Mejia; Rodrigues, Ascédio José; Terra, Ricardo Mingarini; Pego-Fernandes, Paulo Manoel; Carvalho, Carlos Roberto Ribeiro

    2015-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67%) and squamous cell carcinoma (in 24%). For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients.

  15. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  16. Ultrasound-Guided Core-Needle Versus Vacuum-Assisted Breast Biopsy: A Cost Analysis Based on the American Society of Breast Surgeons' Mastery of Breast Surgery Registry.

    Science.gov (United States)

    Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean

    2017-03-01

    To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p cancer diagnosis of $3978 ($3964-$3991) (p cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.

  17. Validation of American Thyroid Association Ultrasound Risk Assessment of Thyroid Nodules Selected for Ultrasound Fine-Needle Aspiration.

    Science.gov (United States)

    Tang, Alice L; Falciglia, Mercedes; Yang, Huaitao; Mark, Jonathan R; Steward, David L

    2017-08-01

    The aim of this study was to validate the American Thyroid Association (ATA) sonographic risk assessment of thyroid nodules. The ATA sonographic risk assessment was prospectively applied to 206 thyroid nodules selected for ultrasound-guided fine-needle aspiration (US-FNA), and analyzed with The Bethesda System for Reporting Thyroid Cytopathology (TBSRTC), as well as surgical pathology for the subset undergoing surgical excision. The analysis included 206 thyroid nodules averaging 2.4 cm (range 1-7 cm; standard error of the mean 0.07). Using the ATA US pattern risk assessment, nodules were classified as high (4%), intermediate (31%), low (38%), and very low (26%) risk of malignancy. Nodule size was inversely correlated with sonographic risk assessment, as lower risk nodules were larger on average (p risk estimates (high 70-90%, intermediate 10-20%, low 5-10%, and very low 3%). ATA US pattern risk assessment also appropriately predicted the proportion of nodules classified as malignant or suspicious for malignancy through TBSRTC classification-high (77%), intermediate (6%), low (1%), and very low 0%-as well as benign TBSRTC classification-high (0%), intermediate (47%), low (61%), and very low (70%) (p risk stratification (high 100%, intermediate 21%, low 17%, and very low 12%; p = 0.003). This prospective study supports the new ATA sonographic pattern risk assessment for selection of thyroid nodules for US-FNA based upon TBSRTC and surgical pathology results. In the setting of indeterminate cytopathology, nodules categorized as atypia of undetermined significance/follicular lesion of undetermined significance with ATA high-risk sonographic patterns have a high likelihood of being malignant.

  18. Multicenter randomized controlled trial comparing the performance of 22 gauge versus 25 gauge EUS-FNA needles in solid masses

    DEFF Research Database (Denmark)

    Vilmann, Peter; S?ftoiu, Adrian; Hollerbach, Stephan

    2013-01-01

    Few randomized studies have assessed the clinical performance of 25-gauge (25G) needles compared with 22-gauge (22G) needles during endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) biopsy of intra-abdominal lesions. We aimed to compare the diagnostic yield, as well as performance...

  19. Performance Accuracy of Hand-on-needle versus Hand-onsyringe Technique for Ultrasound-guided Regional Anesthesia Simulation for Emergency Medicine Residents

    Directory of Open Access Journals (Sweden)

    Brian Johnson

    2014-09-01

    Full Text Available Introduction: Ultrasound-guided nerve blocks (UGNB are increasingly used in emergency care. The hand-on-syringe (HS needle technique is ideally suited to the emergency department setting because it allows a single operator to perform the block without assistance. The HS technique is assumed to provide less exact needle control than the alternative two-operator hand-on-needle (HN technique; however this assumption has never been directly tested. The primary objective of this study was to compare accuracy of needle targeting under ultrasound guidance by emergency medicine (EM residents using HN and HS techniques on a standardized gelatinous simulation model. Methods: This prospective, randomized study evaluated task performance. We compared needle targeting accuracy using the HN and HS techniques. Each participant performed a set of structured needling maneuvers (both simple and difficult on a standardized partial-task simulator. We evaluated time to task completion, needle visualization during advancement, and accuracy of needle tip at targeting. Resident technique preference was assessed using a post-task survey. Results: We evaluated 60 tasks performed by 10 EM residents. There was no significant difference in time to complete the simple model (HN vs. HS, 18 seconds vs. 18 seconds, p=0.93, time to complete the difficult model (HN vs. HS, 56 seconds vs. 50 seconds, p=0.63, needle visualization, or needle tip targeting accuracy. Most residents (60% preferred the HS technique. Conclusion: For EM residents learning UGNBs, the HN technique was not associated with superior needle control. Our results suggest that the single-operator HS technique provides equivalent needle control when compared to the two-operator HN technique. [West J Emerg Med. 2014;15(6:641–646

  20. Application of B-ultrasonic guided fine needle aspiration cytology in diagnosis of tuberculous lymphadenitis

    International Nuclear Information System (INIS)

    Yu Qi; Yang Jianghui; Li Ning

    2011-01-01

    To explore the value of B-ultrasonic guided fine needle aspiration cytology(FNAC) in the diagnosis of tuberculous lymphadenitis (TB). The patients were carried out FNAC under B-ultrasonic guidance to distinguish the tuberculosis lymphadenitis. With the FNAC diagnosis of lymphoglandulae and reactive hyperplasia lesions of 80 cases, 41 cases were confirmed by histopathology. With FNAC diagnosed tuberculosis 36 cases, granulomatous lymphadenitis 2 cases and reactive hyperplasia 3 cases. FANC is one of efficient method to diagnosis the tuberculous lymphadenitis. This method has some limitations, but it could be overcome by biopsy or polymerase chain reaction. (authors)

  1. Free thyroxine in needle washout after fine needle aspiration biopsy of toxic thyroid nodules.

    Science.gov (United States)

    Raikov, Nikolai; Nonchev, Boyan; Chaushev, Borislav; Vjagova, Diyana; Todorov, Svetoslav; Bocheva, Yana; Malceva, Daniela; Vicheva, Snejinka; Raikova, Asyia; Argatska, Antoaneta; Raikov, Miroslav

    2016-01-01

    The main diagnostic tool for toxic adenomas (TA) is radionuclide imaging indicated in patients with evidence of thyroid nodules in combination with thyrotoxic syndrome. Thyroid ultrasound and fine-needle aspiration biopsy (FNAB) are widely used for the valuation of thyroid masses. There is no literature data concerning the utility of FNAB and related tests for the diagnosis of hyperfunctioning thyroid nodules. The purpose of this study is to determine the levels of free thyroxine (FT4) in the needle washout after FNAB of hot thyroid nodules. The results of our study show that the FT4 levels in needle washout from TA were significantly higher than the surrounding parenchyma and correlated with the hormonal changes in patients with thyroid hyperfunctioning nodules. Further studies on a large number of patients are needed to refine the diagnostic value of this method and evaluate its importance in quantitative risk assessment of thyroid autonomy.

  2. Diagnostic value of sonography, ultrasound-guided fine-needle aspiration cytology, and diffusion-weighted MRI in the characterization of cold thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Schueller-Weidekamm, Claudia [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)], E-mail: claudia.schueller-weidekamm@meduniwien.ac.at; Schueller, Gerd [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kaserer, Klaus [Department of Pathology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Scheuba, Christian [Department of Surgery, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Ringl, Helmut; Weber, Michael; Czerny, Christian; Herneth, Andreas M. [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2010-03-15

    Introduction: The purpose of this prospective study was to assess the diagnostic value of different modalities for the characterization of cold thyroid nodules. Methods: In 35 patients with cold nodules, thyroid carcinoma was suspected on scintigraphy. These patients were prospectively investigated with sonography, ultrasound-guided fine-needle aspiration (USgFNA), and quantitative diffusion-weighted imaging magnetic resonance imaging (DWI) (navigated echo-planar imaging; maximum b-value 800 s/mm{sup 2}) prior to surgery. The sonographic findings, USgFNA cytology, and the apparent diffusion coefficient (ADC) values of DWI were correlated with the postoperative histology of benign and malignant lesions. Statistical analysis was performed with the Kruskal-Wallis test and the Fisher's exact test. P < .05 denoted statistical significance. Results: The accuracy of sonography and USgFNA was 64% and 68.8%, respectively. The sensitivity was 86.7% and 80%, respectively. Specificity was only 57.2% and 50%, respectively. The median ADC values for carcinoma and adenoma were 2.73 x 10{sup -3} mm{sup 2}/s and 1.93 x 10{sup -3} mm{sup 2}/s, respectively (P < .001). There was no significant difference between the median ADC value for Hashimoto thyroiditis (3.46 x 10{sup -3} mm{sup 2}/s) and carcinoma. An ADC value of 2.25 x 10{sup -3} mm{sup 2}/s or higher was proven to be the cut-off value for differentiating between benign and malignant cold thyroid nodules, with an accuracy of 88%, a sensitivity of 85%, and a specificity of 100%. Conclusions: These results show that quantitative DWI is a more reliable diagnostic method for differentiation between benign and malignant thyroid lesions than sonography or USgFNA. However, further studies including a larger study population are necessary to confirm our study results.

  3. Practical guidelines for ultrasound-guided core needle biopsy of soft-tissue lesions: Transformation from beginner to specialist

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Yoon; Chung, Hye Won; Oh, Tack Sun; Lee, Jong Seok [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-04-15

    Ultrasound-guided core needle biopsy (US-CNB) is an important step in the diagnosis of musculoskeletal soft-tissue lesions. To maximize efficacy and minimize the complications of US-CNB, it is critical to collaborate with a multidisciplinary team and to understand the particular considerations of US-CNB for these lesions. The purpose of this article is to provide a systematic review and step-by-step tips for using US-CNB to diagnose musculoskeletal soft-tissue lesions.

  4. Fine needle aspiration biopsy of pancreas. Cytological assessment

    International Nuclear Information System (INIS)

    Coufal, L.; Heger, L.

    1987-01-01

    The benefits are presented of cytological examination of bioptical material from the pancreas using computerized tomography (CT) or ultrasound. The case is presented of one patient who had repeatedly undergone endoscopy with no results. Only cytological examination of material sampled using fine needle aspiration under CT control helped to immediately diagnose the process. The cytological finding correlated with the histological examination of material later taken during surgery. The problems are discussed of the differential diagnosis of tumors of the pancreas. (author). 5 figs., 9 refs

  5. Use of CT-guided fine needle aspiration biopsy in epidermal growth factor receptor mutation analysis in patients with advanced lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yi-Ping; Wang, Hai-Yan; Zhang, Jin; Feng, Yong (Dept. of Radiology, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China)), email: yipingzhuang2010@sina.com; Shi, Mei-Qi (Dept. of Chemotherapy, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China))

    2011-12-15

    Background. The safety of using a cutting needle when performing a core-needle biopsy is of major concern, in particular for small lung tumors or tumors near the hilum. Purpose. To investigate the usefulness of CT-guided fine needle aspiration biopsy (FNAB) of the lung in obtaining tumor tissue for epidermal growth factor receptor (EGFR) mutation analysis in advanced lung cancer patients. Material and Methods. Forty-three patients with stage IIIB-IV lung cancer were enrolled. In all patients, CT-guided FNAB was performed using an 18-gauge or 20-gauge Chiba aspiration needle for histology diagnosis and EGFR mutation analysis. Complications associated with CT-guided FNAB were observed, and the specimen mutational assessments were recorded. Results. The obtained tumor samples ranged from 0.5-1.5 cm in length and were adequate for histological and DNA analyses in all patients. No patient had a pneumothorax or hemoptysis. Minor needle tract bleeding appeared in eight patients. Mutation analysis was satisfactorily demonstrated in 23 mutations and 20 non-mutations. Ten and 13 mutations were identified by 18-gauge and 20-gauge needle biopsies, respectively. EFGR mutations, including 12 cases of EGFR exon 19 deletion and 11 cases of exon 21 point mutation, were present in 21 patients with adenocarcinomas, one with squamous cell carcinoma, and one with undifferentiated carcinoma. Conclusion. CT-guided FNAB is a feasible and safe technique for obtaining lung tumor tissues for EGFR gene mutation analysis

  6. Ultrasound-guided radiofrequency neurotomy in cervical spine: sonoanatomic study of a new technique in cadavers

    International Nuclear Information System (INIS)

    Lee, S.-H.; Kang, C.H.; Lee, S.-H.; Derby, R.; Yang, S.N.; Lee, J.E.; Kim, J.H.; Kim, S.S.; Lee, J.-H.

    2008-01-01

    Aim: To develop an ultrasound-guided technique for radiofrequency (RF) cervical medial branch neurotomy and to validate the accuracy of this new method. Materials and methods: Five non-embalmed, fresh cadavers were used; three male and two female cadavers with a median age at death of 67.2 years (range 50-84 years). This study was conducted in two parts. First, two of the cadavers were used to define the sonographic target point for RF cervical medial branch neurotomy using high-resolution ultrasound (12 to 5 MHz). The needles were guided to five consecutive cervical medial branches in the cadavers under ultrasound guidance. Subsequently, the position of the ultrasound-guided needle was verified using C-arm fluoroscopy. Ultrasound-guided RF neurotomy was performed to the C5 medial branches in all five cadavers. In the three cadavers not used in the first part of the study, ultrasound-guided RF neurotomy without C-arm fluoroscopic confirmation was performed to the C3-C7 medial branches. The accuracy of neurotomy was assessed by pathological examination of the cervical medial branches obtained through cadaver dissection. Results: In all five cadavers, the sonographic target point was identified in all C3-C7 segments with the 12 to 5 MHz linear transducer. In all 20 needle placements for the first and second cadavers, C-arm fluoroscopy validated proper needle tip positions. In all five cadavers, successful neurotomy was pathologically confirmed in 30 of 34 cervical medial branches. Conclusions: Ultrasound-guided cervical medial branch neurotomy was successfully performed in 30 of 34 cervical medial branches in five cadavers. However, before eliminating fluoroscopic validation of final needle tip positioning, the technique should be validated in symptomatic patients

  7. Effect of a Biopsy Center on Adequacy Rates of Thyroid Nodule Fine-Needle Aspiration.

    Science.gov (United States)

    Leung, Vincent A; Kirpalani, Anish; Mnatzakanian, Gevork; Colak, Errol; Vlachou, Paraskevi A

    2017-08-01

    The purpose of this study was to investigate the effect of a biopsy center-a dedicated space with a dedicated ultrasound machine and technologist, staffed daily by a radiologist responsible for performing ultrasound-guided procedures only-on the rate of non-diagnostic or unsatisfactory thyroid fine-needle aspiration (FNA). Three radiologists performed FNA on 1200 nodules in 998 patients between September 2010 and November 2015. We compared rates of nondiagnostic or unsatisfactory FNA before and after implementation of a biopsy center in September 2014 as part of a quality improvement initiative. Before the establishment of our biopsy center, ultrasound-guided procedures were scheduled between diagnostic studies in the main ultrasound department and were performed by a radiologist responsible for both. Multivariate logistic regression analysis was performed to assess the effect of the biopsy center on the odds of obtaining an adequate sample. Rates of nondiagnostic or unsatisfactory FNA decreased significantly from 15.1% to 8.5% (p < 0.001) after implementation of the biopsy center. The odds of obtaining an adequate sample were higher in the biopsy center (odds ratio, 2.07; 95% CI, 1.43-3.01), even after adjusting for patient age, nodule size, the radiologist performing the procedure, and time over the study period. The implementation of a biopsy center was associated with significantly lower rates of nondiagnostic or unsatisfactory thyroid FNA, suggesting target rates of 10% or lower are achievable with quality improvement measures.

  8. Cytological and sonographic correlation of the biopsies by fine needle aspiration (FNAB) of thyroid nodules in the Hospital San Rafael de Alajuela of July 1, 2006 to February 28, 2007

    International Nuclear Information System (INIS)

    Barrantes Vega, Jesus

    2007-01-01

    The importance of the use of aspiration biopsy with ultrasonic-guided fine needle is recognized as screening method for diagnosis of thyroid nodules. Thyroid nodules are very common, the prevalence of palpitation has been estimated by 4% and 6% by ultrasound. The prevalence in autopsy data of patients with no history of thyroid pathology has been up to 50%. The use set of advanced imaging techniques and modified techniques of biopsy is implemented in order to increase the diagnostic security of thyroid lesions. The incidental finding of thyroid nodules or incidentalomas has soared dizzily, since the advent of ultrasound as an element in the valuation of thyroid disease and thyroid in the neck. Incidence has been reported even up to 40%. A growing number of endocrinologists are using aspiration biopsy with ultrasound guided fine needle of thyroid nodules as initial diagnostic procedure to identify discrete nodules with a direct location. The percentage of malignant nodules or that require surgery by size or symptomatology, generally, is very low, had to be established a systematic approach to reducing morbidity and mortality associated with major surgery of the neck and reduce costs. The biopsy by fine needle aspiration has been a well established diagnostic technique for preoperative evaluation of thyroid nodules, which has led a significant reduction in the number of unnecessary surgeries in most centers has been between 35-75%. This biopsy has been a specific method, sensitive and inexpensive. The sonographic guidance for biopsy by fine needle aspiration offers the following benefits: is safe and inexpensive, able to reduce costs in 25%, minimally invasive and highly effective, this guidance has increased the detection of malignancy of 14 to 39%. Among the complications that can occur is the formation of hematoma and pain, which are rare. On the other hand, the sonographic guidance is essential for biopsy nonpalpable nodules helping to ensure proper placement of

  9. Endoscopic ultrasound guided biopsy performed routinely in lung cancer staging spares futile thoracotomies

    DEFF Research Database (Denmark)

    Larsen, Soeren S; Vilmann, Peter; Krasnik, Mark

    2005-01-01

    BACKGROUND: Up to 45% of operations with curative intent for non-small-cell lung cancer (NSCLC) can be regarded as futile, apparently because the stage of the disease is more advanced than expected preoperatively. During the past decade several studies have evaluated the usefulness of endoscopic...... ultrasound guided fine needle aspiration biopsy (EUS-FNA) in lung cancer staging with promising results. However, no randomised trials have been performed, in which a staging strategy with EUS-FNA performed in all patients is compared with a conventional workup. METHODS: Before surgery (i.e. mediastinoscopy...

  10. Cytopathologist-performed and ultrasound-guided fine needle aspiration cytology enhances diagnostic accuracy and avoids pitfalls: An overview of 20 years of personal experience with a selection of didactic cases.

    Science.gov (United States)

    Paksoy, Nadir; Ozbek, Busra

    2018-01-01

    Over the last few decades, fine needle aspiration cytology (FNA) has emerged as a SAFE (Simple, Accurate, Fast, Economical) diagnostic tool based on the morphologic evaluation of cells. The first and most important step in obtaining accurate results from FNA is to procure sufficient and representative material from the lesion and to appropriately transfer this material to the laboratory. Unfortunately, the most important aspect of this task occurs beyond the control of the cytopathologist, a key reason for obtaining unsatisfactory results with FNA. There is growing interest in the field of cytology in "cytopathologist-performed ultrasound (US)-guided FNA," which has been reported to yield accurate results. The first author has been applying FNA in his own private cytopathology practice with a radiologist and under the guidance of US for more than 20 years. This study retrospectively reviews the utility of this practice. We present a selection of didactic examples under different headings that highlight the application of FNA by a cytopathologist, accompanied by US, under the guidance of a radiologist, in the form of an "outpatient FNA clinic." The use of this technique enhances diagnostic accuracy and prevents pitfalls. The highlights of each case are also outlined as "take-home messages."

  11. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo [Chonnam National University Hospital, Chonnam National University Medical School, Gwangju(Korea, Republic of)

    2017-04-15

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications.

  12. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Shin, Sang Soo

    2017-01-01

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications

  13. Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration for Staging of Patients with Non-Small Cell Lung Cancer without Mediastinal Involvement at Positron Emission Tomography-Computed Tomography

    DEFF Research Database (Denmark)

    Naur, Therese Maria Henriette; Konge, Lars; Clementsen, Paul Frost

    2017-01-01

    BACKGROUND: Staging of lung cancer is essential to the treatment, which is curative only in cases of localized disease. Previous studies have suggested that endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is unnecessary when positron emission tomography-computed tomog...

  14. Therapeutic aspects of endoscopic ultrasound

    Science.gov (United States)

    Woodward, Timothy A.

    1999-06-01

    Endoscopic ultrasound (EUS) is a technology that had been used primarily as a passive imaging modality. Recent advances have enabled us to move beyond the use of EUS solely as a staging tool to an interventional device. Current studies suggest that interventional applications of EUS will allow for minimally invasive assessment and therapies in a cost-effective manner. Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has been demonstrated to be a technically feasible, relatively safe method of obtaining cytologic specimens. The clinical utility of EUS- FNA appears to be greatest in the diagnosis and staging of pancreatic cancer and in the nodal staging of gastrointestinal and pulmonary malignancies. In addition, EUS-FNA has demonstrated utility in the sampling pleural and ascitic fluid not generally appreciated or assessable to standard interventions. Interventional applications of EUS include EUS-guided pseudocyst drainage, EUS-guided injection of botulinum toxin in the treatment of achalasia, and EUS- guided celiac plexus neurolysis in the treatment of pancreatic cancer pain. Finally, EUS-guided fine-needle installation is being evaluated, in conjunction with recent bimolecular treatment modalities, as a delivery system in the treatment of certain gastrointestinal tumors.

  15. Percutaneous tenotomy: development of a novel, percutaneous, ultrasound-guided needle-cutting technique for division of tendons and other connective tissue structures

    International Nuclear Information System (INIS)

    Hopkins, James; Sampson, Matthew

    2014-01-01

    A variety of surgical procedures derive therapeutic benefit from the division of retinacular, ligamentous or tendinous structures. Examples include carpal tunnel release for median nerve impingement, annular pulley release for trigger finger and tendon division for spastic muscular contractures. Here, using an animal cadaveric model, we describe the first steps in determining the feasibility of a novel, percutaneous, ultrasound-guided needle-cutting technique to achieve the same ends. The technique we describe involves the creation of an effective needle tenotomy device via a simple modification to an 18G coaxial, beveled needle. The technique holds promise for the development of a minimally invasive alternative approach that utilises readily available technology and equipment with minimisation of morbidity and cost associated with open procedures.

  16. Harmonic Contrast-Enhanced Endoscopic Ultrasonography for the Guidance of Fine-Needle Aspiration in Solid Pancreatic Masses

    DEFF Research Database (Denmark)

    Seicean, A; Badea, R; Moldovan-Pop, A

    2015-01-01

    Purpose: The global accuracy of fine-needle aspiration guided by endoscopic ultrasound (EUS-FNA) for pancreatic adenocarcinoma is about 85 %. The use of contrast agents during EUS to highlight vessels and the necrotic parts of pancreatic masses may improve biopsy guidance. Our aim was to assess...... whether the guidance of FNA by harmonic contrast-enhanced endoscopic ultrasound (CH-EUS) would increase diagnostic accuracy relative to conventional EUS-FNA in the same pancreatic masses. Patients and Methods: In a prospective study, EUS-FNA was performed in patients with pancreatic masses on CT scan......, followed by harmonic CH-EUS using SonoVue. A second cluster of CH-EUS-FNA was performed on contrast-enhanced images. The final diagnosis was based on the results of EUS-FNA and surgery, or the findings after 12 months' follow-up. Results: The final diagnosis was adenocarcinoma (n = 35), chronic...

  17. Ultrasound guided needle biopsy of skeletal muscle in neuromuscular disease

    DEFF Research Database (Denmark)

    Lindequist, S; Schrøder, H D; Larsen, C

    1990-01-01

    Guided by ultrasonography percutaneous needle biopsy of skeletal muscle was performed in 24 patients, using the one hand held Biopty system and a 2 mm Tru-Cut needle. The specimens were graded with regard to diagnostic quality and utility and almost all specimens (96%) were of highest quality. Th....... The use of ultrasonography was helpful in selecting a suitable area for the biopsy and vascular structures could be avoided. The procedure was well tolerated and easy to perform, and no complications were recorded....

  18. Fine-needle versus core-needle biopsy – which one to choose in preoperative assessment of focal lesions in the breasts? Literature review

    Directory of Open Access Journals (Sweden)

    Ewa Łukasiewicz

    2017-12-01

    Full Text Available Aim: The aim of the study was to review two techniques that can be used to verify focal lesions in the breasts: fine-needle aspiration biopsy and core-needle biopsy. Material and methods: Fifty-five articles (original papers and reviews, half of them published within the past 5 years, were included in the analysis. The authors also took their own experience into account. Results: Pre-operative assessment of focal lesions in the breasts is crucial in the planning of further therapeutic management. The role of fine-needle aspiration biopsy has been reduced lately due to its low sensitivity and specificity as well as a high rate of non-diagnostic, suspicious and false negative results. This method does not enable one to differentiate between in situ and invasive disease. Currently, fine-needle biopsy is recommended for cystic lesions, suspected of being recurrences in the chest wall, and lymph node metastases. Core-needle biopsy is the basic diagnostic method of breast lesions. According to the recommendations of the Polish Ultrasound Society and American College of Radiology, BIRADS 4 and 5 lesions should be evaluated histopathologically. Core-needle biopsy makes it possible to establish a final diagnosis more frequently than fine-needle biopsy, both in the case of benign and malignant lesions. It delivers more information about the nature of a tumor (mutation of HER-2, estrogen and progesterone receptors and Ki-67 index. Its limitations include: underestimation of invasion and failure to recognize the components of ductal carcinoma in situ in papillary and atypical lesions. Single fine-needle aspiration biopsy is inexpensive, but when considering the cost of further diagnosis due to non-diagnostic, suspicious and atypical results, this method generates high additional costs. Conclusions: Microscopic verification of focal breast lesions is crucial for further therapeutic decisions. It has been proven that histopathological verification is more

  19. Technical Note: Error metrics for estimating the accuracy of needle/instrument placement during transperineal magnetic resonance/ultrasound-guided prostate interventions.

    Science.gov (United States)

    Bonmati, Ester; Hu, Yipeng; Villarini, Barbara; Rodell, Rachael; Martin, Paul; Han, Lianghao; Donaldson, Ian; Ahmed, Hashim U; Moore, Caroline M; Emberton, Mark; Barratt, Dean C

    2018-04-01

    Image-guided systems that fuse magnetic resonance imaging (MRI) with three-dimensional (3D) ultrasound (US) images for performing targeted prostate needle biopsy and minimally invasive treatments for prostate cancer are of increasing clinical interest. To date, a wide range of different accuracy estimation procedures and error metrics have been reported, which makes comparing the performance of different systems difficult. A set of nine measures are presented to assess the accuracy of MRI-US image registration, needle positioning, needle guidance, and overall system error, with the aim of providing a methodology for estimating the accuracy of instrument placement using a MR/US-guided transperineal approach. Using the SmartTarget fusion system, an MRI-US image alignment error was determined to be 2.0 ± 1.0 mm (mean ± SD), and an overall system instrument targeting error of 3.0 ± 1.2 mm. Three needle deployments for each target phantom lesion was found to result in a 100% lesion hit rate and a median predicted cancer core length of 5.2 mm. The application of a comprehensive, unbiased validation assessment for MR/US guided systems can provide useful information on system performance for quality assurance and system comparison. Furthermore, such an analysis can be helpful in identifying relationships between these errors, providing insight into the technical behavior of these systems. © 2018 American Association of Physicists in Medicine.

  20. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    International Nuclear Information System (INIS)

    Kang, Yun Dan; Kim, You Me

    2016-01-01

    The purpose of this study was to compare needle aspiration and vacuum-assisted biopsy in the ultrasound-guided treatment of lactational breast abscesses. Between January 2005 and December 2014, a total of 74 patients presented with lactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated with needle aspiration (n=25) or vacuum-assisted biopsy (n=19). Age, duration of lactation, abscess diameter, pus culture results, the number of interventions, the healing time, and the cure rate were reviewed and compared between these two groups. The Student's t test and the chi-square test were used to compare the variables. No significant difference was found in the cure rate between the needle aspiration group (22/25, 88%) and the vacuum-assisted biopsy group (18/19, 94.7%) (P=0.441). However, the mean healing time was significantly shorter in the vacuum-assisted biopsy group (6.7 days) than in the needle aspiration group (9.0 days) (P=0.001). Vacuum-assisted biopsy is a viable option for the management of lactational breast abscesses and was found to lead to a shorter healing time than needle aspiration. However, further study is necessary to establish the clinical efficacy of vacuum-assisted biopsy in the management of lactational breast abscesses

  1. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yun Dan; Kim, You Me [Dankook University College of Medicine, Cheonan (Korea, Republic of)

    2016-03-15

    The purpose of this study was to compare needle aspiration and vacuum-assisted biopsy in the ultrasound-guided treatment of lactational breast abscesses. Between January 2005 and December 2014, a total of 74 patients presented with lactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated with needle aspiration (n=25) or vacuum-assisted biopsy (n=19). Age, duration of lactation, abscess diameter, pus culture results, the number of interventions, the healing time, and the cure rate were reviewed and compared between these two groups. The Student's t test and the chi-square test were used to compare the variables. No significant difference was found in the cure rate between the needle aspiration group (22/25, 88%) and the vacuum-assisted biopsy group (18/19, 94.7%) (P=0.441). However, the mean healing time was significantly shorter in the vacuum-assisted biopsy group (6.7 days) than in the needle aspiration group (9.0 days) (P=0.001). Vacuum-assisted biopsy is a viable option for the management of lactational breast abscesses and was found to lead to a shorter healing time than needle aspiration. However, further study is necessary to establish the clinical efficacy of vacuum-assisted biopsy in the management of lactational breast abscesses.

  2. Fine needle aspiration cytology of cervicofacial actinomycosis

    Directory of Open Access Journals (Sweden)

    Venkatesh Kusuma

    2008-01-01

    Full Text Available Actinomycosis is a chronic infection caused by Actinomyces israelii, usually seen in immunocompromised patients or in the background of tissue injury. Cervicofacial actinomycosis presenting as a fixed jaw swelling in an elderly individual can mimic malignancy and pose a diagnostic dilemma. We report here a case of cervicofacial actinomycosis diagnosed by fine needle aspiration, along with a review of the relevant literature. A 60 year-old man presented with a gradually increasing 6 x 5 cm swelling in the left side of his jaw. The swelling was fixed, without any apparent sinus or abscess. Fine needle aspiration was diagnostic as it revealed colonies of actinomyces surrounded by polymorphs and chronic inflammatory cells. The histopathological study of the excised specimen confirmed the cytological findings. Fine needle aspiration is an effective tool in the diagnosis of actinomycosis although its documentation is rare. Difficulties in the management can be avoided by early diagnosis using the fine needle aspiration technique.

  3. Mediastinal abscess after endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    Science.gov (United States)

    Leong, Steven C; Marshall, Henry M; Bint, Michael; Yang, Ian A; Bowman, Rayleen V; Fong, Kwun M

    2013-10-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive technique that allows lung cancer nodal staging and biopsy of parabronchial and paratracheal tissue. Its simplicity, high diagnostic yield, ability to diagnose both benign and malignant conditions, and exceedingly low complication rate has resulted in rapid widespread adoption by surgeons and physicians. EBUS-TBNA-related complications, however, do occur and need to be considered when assessing the risk-benefit profile of performing the procedure, and if the patient represents with unexpected symptoms after the procedure. We describe a 64-year-old woman who presented with a mediastinal abscess 5 days after EBUS-TBNA. This case demonstrates the importance of considering EBUS-TBNA-related complications to guide relevant imaging decisions and antibiotic choices. We review the published literature regarding infective complications of EBUS-TBNA and propose possible pathophysiologies. These complications are likely to increase in frequency as the technique is more widely adopted.

  4. Percutaneous CT-Guided Core Needle Biopsy Versus Fine Needle Aspiration in Diagnosing Pneumonia and Mimics of Pneumonia

    International Nuclear Information System (INIS)

    Thanos, Loukas; Galani, Panagiota; Mylona, Sophia; Pomoni, Maria; Mpatakis, Nikolaos

    2004-01-01

    The purpose of this study was to determine the diagnostic value of percutaneous core needle biopsy (CNB) relative to fine needle aspiration (FNA) in patients with pneumonia and pneumonia mimics. In this prospective study we present our experience with 48 thoracic FNAs and CNBs carried out on 48 patients with pneumonia and pneumonia mimics. Samples were obtained from all patients using both CNB (with an automated 18-G core biopsy needle and a gun) and FNA (with a 22-G needle). A specific diagnosis was made in 10/48 cases (20.83%) by FNA and in 42/48 (87.5%) by CNB. The main complications encountered were pneumothorax (n = 4) and hemoptysis (n = 2), yielding a total complication rate of 12.5%. We concluded that CNB using an automated biopsy gun results in a higher diagnostic accuracy for pneumonia and pneumonia mimic biopsies than FNA. Complications should be considered and proper patient observation should follow the procedure

  5. [Endoscopic ultrasound guided rendezvous for biliary drainage].

    Science.gov (United States)

    Knudsen, Marie Høxbro; Vilmann, Peter; Hassan, Hazem; Karstensen, John Gésdal

    2015-04-27

    Endoscopic retrograde cholangiography (ERCP) is currently standard treatment for biliary drainage. Endoscopic ultrasound guided rendezvous (EUS-RV) is a novel method to overcome an unsuccessful biliary drainage procedure. Under endoscopic ultrasound guidance a guidewire is passed via a needle from the stomach or duodenum to the common bile duct and from there on to the duodenum enabling ERCP. With a relatively high rate of success EUS-RV should be considered as an alternative to biliary drainage and surgical intervention.

  6. Standards of the Polish Ultrasound Society – update. Ultrasound examination of thyroid gland and ultrasound-guided thyroid biopsy

    Directory of Open Access Journals (Sweden)

    Anna Trzebińska

    2014-03-01

    Full Text Available Ultrasonography is a primary imaging technique in patients with suspected thyroid disease. It allows to assess the location, size and echostructures of the thyroid gland as well as detect focal lesions, along with indication of their size, echogenicity, echostructure and vascularity. Based on these features, ultrasound examination allows to predict abnormal focal lesions for biopsy and monitor the biopsy needle track. This paper presents the standards of thyroid ultrasound examination regarding ultrasound apparatus technical requirements, scanning techniques, readings, measurements, and the description of the examination. It discusses the ultrasound features of increased malignancy risk in focal lesions (nodules found in the thyroid gland. It presents indications for fine needle aspiration biopsy of the thyroid gland for the visibility of single nodules (focal lesions and numerous lesions as well as discusses contraindications for thyroid biopsy. It describes the biopsy technique, possible complications and rules for post-biopsy monitoring of benign lesions. The paper is an update of the Standards of the Polish Ultrasound Society issued in 2011. It has been prepared on the basis of current literature, taking into account the information contained in the following publications: Thyroid ultrasound examination and Recommendations of the Polish Ultrasound Society for the performance of the FNAB of the thyroid.

  7. EUS needle identification comparison and evaluation (NICE) study (with videos)

    Science.gov (United States)

    Tang, Shou-jiang; Vilmann, Andreas S.; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin; Fink, Peter P.; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F.; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T.; van der Heijden, Erik H.F.M.; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H.; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R.; Lee, Linda S.; Aslanian, Harry R.; Wang, Andrew Y.; Shami, Vanessa M.; Markowitz, Arnold; Siddiqui, Ali A.; Mishra, Girish; Scheiman, James M.; Isenberg, Gerard; Siddiqui, Uzma D.; Shah, Raj J.; Buxbaum, James; Watson, Rabindra R.; Willingham, Field F.; Bhutani, Manoop S.; Levy, Michael J.; Harris, Cynthia; Wallace, Michael B.; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D’Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S.; Freeman, Simon; McCowan, Timothy C.; de Araujo, Cyrillo Rodrigues; Patel, Akash; del Ali, Mohammad A; Campbell, Garth; Chen, Edward; Vilmann, Peter

    2017-01-01

    Background and Aims Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) or biopsy is widely practiced. Optimal sonographic visualization of the needle is critical for image guided interventions. There are several commercially available needles but no bench-top testing and direct comparison of these needles to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Methods Descriptive bench-top testing and comparison. Bench-top testing of 8 commonly used EUS-FNA needles (all of 22 gauge in size): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition, (Cook Medical); ClearView (Conmed); EZ Shot2 (Olympus); BNX (Beacon Endoscopic); and 2 new prototype needles that are coated by echogenic polymers by Medi-Globe. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in gastrointestinal ultrasound examination that is unfamiliar with EUS needle devices. Results There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, one prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (p<0.01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%–75% worse, p<0.001). Conclusions All FNA needles have their inherent and different echogenicity, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. PMID:26873530

  8. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.

    Science.gov (United States)

    Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik

    2017-07-15

    The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (pcore (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.

  9. Punção Aspirativa por Agulha Fina Orientada por Ultra-Sonografia em Lesões Não-palpáveis Fine Needle Aspiration Cytology Guided by Ultrasound in Nonpalpable Lesions

    Directory of Open Access Journals (Sweden)

    Cláudio Kemp

    2001-06-01

    Full Text Available Objetivo: correlacionar os achados citológicos obtidos por punção com agulha fina dirigida pela ultra-sonografia de lesões não-palpáveis da mama, císticas ou sólidas, os aspectos ultra-sonográficos e os respectivos resultados histopatológicos das lesões que foram submetidas a cirurgia. Métodos: foram analisadas 617 lesões não-palpáveis visualizadas ao ultra-som. Realizou-se a punção aspirativa por agulha fina (PAAF orientada pela ultra-sonografia, com análise citológica do material, diferenciando-as em cistos ou nódulos sólidos. Estes tiveram seu resultado citológico confrontado com o resultado histopatológico, nos casos em que foi realizada a biópsia cirúrgica. Resultados: das 617 lesões não-palpáveis, 471 eram cistos, sendo 451 cistos simples que apresentaram citologia negativa em todos os casos e 20 casos foram considerados cistos complexos. Destes, 3 (15% tiveram resultado citológico positivo ou suspeito e em 2 casos confirmou-se malignidade. Dos 105 nódulos sólidos, 63 apresentaram citologia negativa, sendo 59 concordantes com a biópsia e houve 4 casos (0,3% de resultado falso-negativo pela citologia. Todos, porém, apresentavam discordância entre imagem e citologia. Em 14 nódulos sólidos (13%, a citologia foi suspeita e, destes, 5 foram diagnosticados como carcinoma. Em outros 14 (13%, o material foi insatisfatório e 1 era carcinoma. Em 51 casos, o tríplice diagnóstico foi concordante e optou-se por seguimento clínico. Conclusão: a análise citológica do material dos cistos mamários simples é desnecessária, porém quando são complexos, a citologia é imperativa. Nas lesões sólidas não-palpáveis, é fundamental a correlação da citologia com o aspecto ultra-sonográfico e mamográfico; caso sejam discordantes, deve-se sempre prosseguir a investigação da lesão.Purpose: to determine the relationship between fine needle aspiration cytology guided by ultrasound of nonpalpable breast lesions

  10. False Negative Fine Needle Aspiration Biopsy Results in Primary Thyroid Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Joong; Kim, Eun Kyung; Koh, Myoung Ju; Kwak, Jin Young; Moon, Hee Jung [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2012-06-15

    Ultrasonography-guided fine needle aspiration biopsy (US-FNA) is one of the methods used to diagnose thyroid lymphoma, but it has a relatively high false-negative rate. The authors report a case of a primary thyroid lymphoma associated with underlying lymphocytic thyroiditis that was initially misdiagnosed as lymphocytic thyroiditis based on US-FNA findings

  11. The accuracy of frozen section analysis in ultrasound- guided core needle biopsy of breast lesions

    International Nuclear Information System (INIS)

    Brunner, Andreas H; Sagmeister, Thomas; Kremer, Jolanta; Riss, Paul; Brustmann, Hermann

    2009-01-01

    Limited data are available to evaluate the accuracy of frozen section analysis and ultrasound- guided core needle biopsy of the breast. In a retrospective analysis data of 120 consecutive handheldultrasound- guided 14- gauge automated core needle biopsies (CNB) in 109 consecutive patients with breast lesions between 2006 and 2007 were evaluated. In our outpatient clinic120 CNB were performed. In 59/120 (49.2%) cases we compared histological diagnosis on frozen sections with those on paraffin sections of CNB and finally with the result of open biopsy. Of the cases 42/59 (71.2%) were proved to be malignant and 17/59 (28.8%) to be benign in the definitive histology. 2/59 (3.3%) biopsies had a false negative frozen section result. No false positive results of the intraoperative frozen section analysis were obtained, resulting in a sensitivity, specificity and positive predicting value (PPV) and negative predicting value (NPV) of 95%, 100%, 100% and 90%, respectively. Histological and morphobiological parameters did not show up relevance for correct frozen section analysis. In cases of malignancy time between diagnosis and definitive treatment could not be reduced due to frozen section analysis. The frozen section analysis of suspect breast lesions performed by CNB displays good sensitivity/specificity characteristics. Immediate investigations of CNB is an accurate diagnostic tool and an important step in reducing psychological strain by minimizing the period of uncertainty in patients with breast tumor

  12. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    Directory of Open Access Journals (Sweden)

    Yun-Dan Kang

    2016-04-01

    Full Text Available Purpose: The purpose of this study was to compare needle aspiration and vacuum-assistedbiopsy in the ultrasound-guided treatment of lactational breast abscesses. Methods: Between January 2005 and December 2014, a total of 74 patients presented withlactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated withneedle aspiration (n=25 or vacuum-assisted biopsy (n=19. Age, duration of lactation, abscess diameter, pus culture results, the number of interventions, the healing time, and the cure rate were reviewed and compared between these two groups. The Student’s t test and the chi-square test were used to compare the variables. Results: No significant difference was found in the cure rate between the needle aspirationgroup (22/25, 88% and the vacuum-assisted biopsy group (18/19, 94.7% (P=0.441. However, the mean healing time was significantly shorter in the vacuum-assisted biopsy group (6.7 days than in the needle aspiration group (9.0 days (P=0.001. Conclusion: Vacuum-assisted biopsy is a viable option for the management of lactational breast abscesses and was found to lead to a shorter healing time than needle aspiration. However, further study is necessary to establish the clinical efficacy of vacuum-assisted biopsy in the management of lactational breast abscesses.

  13. Pancreatic metastasis in a case of small cell lung carcinoma: Diagnostic role of fine-needle aspiration cytology and immunocytochemistry

    Directory of Open Access Journals (Sweden)

    Dilip K Das

    2011-01-01

    Full Text Available Small cell lung carcinoma represents a group of highly malignant tumors giving rise to early and widespread metastasis at the time of diagnosis. However, the pancreas is a relatively infrequent site of metastasis by this neoplasm, and there are only occasional reports on its fine needle aspiration (FNA cytology diagnosis. A 66-year-old man presented with extensive mediastinal lymphadenopathy and a mass in the pancreatic tail. Ultrasound-guided FNA smears from the pancreatic mass contained small, round tumor cells with extensive nuclear molding. The cytodiagnosis was metastatic small cell carcinoma. Immunocytochemical staining showed that a variable number of neoplastic cell were positive for cytokeratin, chromogranin A, neurone-specific enolase and synaptophysin but negative for leukocyte common antigen. The trans-bronchial needle aspiration was non-diagnostic, but biopsy was suspicious of a small cell carcinoma. This case represents a rare metastatic lesion in the pancreas from small cell lung carcinoma, diagnosed by FNA cytology.

  14. Discordance Rate between Thyroid Fine Needle Aspiration Cytology ...

    African Journals Online (AJOL)

    Discordance Rate between Thyroid Fine Needle Aspiration Cytology and Histopathologic Diagnosis. Wondwossen Ergete, Daniel Abebe. Abstract. Fine Needle Aspiration (FNA) of the thyroid is a low cost procedure, which can give an accurate diagnosis promptly. The objective of this study was to assess the diagnostic ...

  15. Riedel thyroiditis: Fine needle aspiration findings of a rare entity.

    Science.gov (United States)

    Weidner, Anna-Sophie; Molina, David; DeSimone, Robert A; Cohen, Marc A; Giorgadze, Tamar; Scognamiglio, Theresa; Hoda, Rana S

    2015-09-01

    Riedel thyroiditis is a rare fibrosing disorder characterized by extension of the fibroinflammatory process beyond the thyroid capsule. Due to the nature of this lesion, fine-needle aspiration often yields scant material and may be interpreted as non-diagnostic. In this report, we describe cytologic features that allow the cytopathologist to favor a diagnosis of Riedel thyroiditis, thereby guiding appropriate further work-up and management. © 2015 Wiley Periodicals, Inc.

  16. Preoperative axillary lymph node staging by ultrasound-guided cytology using a four-level sonographic score

    International Nuclear Information System (INIS)

    De Coninck, Caroline; Noël, Jean-Christophe; Boutemy, Rachel; Simon, Philippe

    2016-01-01

    The staging of axillary lymph nodes is critical to the management and prognosis of breast cancer, the most frequent cancer in females. Neoadjuvant therapy and lymph node dissection are recommended when malignant cells invade the lymph nodes. Therefore the pre-operative examination of these lymph nodes is crucial to treatment. In this study, we examined the effectiveness of cytology through ultrasound-guided fine needle aspiration (USG-FNA) and ultrasound (US) imaging using an established classification system in correctly identifying lymph node status compared to the final histological results after surgery. Cytology by USG-FNA and US classification were found to be promising methods of axillary lymph node staging. US and CB offer minimally invasive techniques to pre-operatively examine these lymph nodes in patients with primary breast cancer

  17. Amoebic liver abscess: Drained by ultrasound guided percutaneous ...

    African Journals Online (AJOL)

    Summary: Amoebic Liver Abscess in a 20-month-old child: A case of amoebic liver abscess in a Nigerian child is presented. Management consisted of 10days course of Metronidazole and 5days course of Tinidazole without improvement. This was followed by four sessions of ultrasound guided percutaneous needle ...

  18. Ultrasound-guided, vacuum-assisted biopsy in evaluation of breast lesions

    International Nuclear Information System (INIS)

    Luczynska, E.; Kocurek, A.; Dyczek, S.; Skotnicki, P.; Stelmach, A.; Herman, K.

    2008-01-01

    Aim. Evaluation of the efficacy of ultrasound-guided vacuum-assisted biopsy for the verification of breast lesions. Introduction. Ultrasound breast examination is a noninvasive method of breast imaging. It is adjunct to mammography and physical examination and, in women under 30 years of age, pregnant and lactating, it is the basic examination used for the detection and diagnosing of breast diseases. It allows also to obtain cells or tissue samples with such minimally invasive techniques as fine-needle biopsy, core needle biopsy or vacuum-assisted biopsy. Material and methods. The study group consisted of 138 women, aged from 20 to 76 years, who underwent ultrasound guided vacuum-assisted biopsy between March and December 2006. Because double lesions were diagnosed in 6 patients, this resulted in 144 performed procedures. Each patient underwent ultrasound examination, performed with a 10-12 MHz transducer. Biopsies were guided by a 12 MHz transducer and performed with the Mammotome System using an 11G or an 8G needle, depending upon the size and site of the lesion. Obtained data were compared using the Chi-square test; p values of less than 0.05 were considered indicative of a significant difference. Results. The average size of the biopted lesions was estimated as 11±3,8 mm (range: 4-30 mm). However, lesions described by radiologists as apparently suspicious were not qualified for the vacuum-assisted biopsy, in the tested material 4 lesions appeared to be carcinomas (3 were invasive breast carcinomas and 1 was ductal carcinoma in situ). When compared with other changes, these lesions were most frequently equivocal (3 vs 1 determined as benign, p=0.014). There was no statistically significant difference in echogenicity (3 hypoechoic vs 1 with mixed echogenicity) nor in the shape (1 oval change, 2 lobulated and 1 irregular). Pathological examination revealed 86 cases of fibroadenoma within the tested material. Those lesions were mostly benign (77 vs 9 equivocal

  19. Endoscopic ultrasound with fine needle aspiration and biopsy in lung cancer and isolated mediastinal lymphadenopathy.

    LENUS (Irish Health Repository)

    Nadarajan, P

    2010-03-01

    Endoscopic ultrasound with fine-needle aspiration and biopsy (EUS-FNAB) is well established in diagnosing and staging lung cancer in patients with mediastinal adenopathy. EUS-FNAB is highly sensitive, less invasive and has lower complication rates when compared to surgical staging of mediastinal nodes. In this study we describe our experience of EUS-FNAB in lung cancer and other causes of mediastinal lymphadenopathy. EUS-FNAB was performed for assessment of PET positive mediastinal lymph nodes between January 2007 and March 2009 in AMNCH. The endpoints of our study were sensitivity and specificity of EUS-FNAB, morbidity and length of hospital stay. Thirty four patients underwent EUS-FNAB during the study period for both diagnosis and staging. Thirty patients had positive lymph node invasion and 4 had no evidence of malignant invasion. In these 4 patients negative cytology was confirmed on mediastinoscopy giving EUS-FNAB a sensitivity and specificity of 100%. EUS-FNAB upstaged the disease in 12 patients. EUS-FNAB is a reliable tool for mediastinal staging in lung cancer, significantly reducing the need for surgical staging procedures in patients with suspected mediastinal involvement.

  20. Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

    Directory of Open Access Journals (Sweden)

    Chang Tsai-Wang

    2010-07-01

    Full Text Available Abstract Background The aims of this study were to determine the accuracy of concurrent core needle biopsy (CNB and fine needle aspiration biopsy (FNAB for breast lesions and to estimate the false-negative rate using the two methods combined. Methods Over a seven-year period, 2053 patients with sonographically detectable breast lesions underwent concurrent ultrasound-guided CNB and FNAB. The sonographic and histopathological findings were classified into four categories: benign, indeterminate, suspicious, and malignant. The histopathological findings were compared with the definitive excision pathology results. Patients with benign core biopsies underwent a detailed review to determine the false-negative rate. The correlations between the ultrasonography, FNAB, and CNB were determined. Results Eight hundred eighty patients were diagnosed with malignant disease, and of these, 23 (2.5% diagnoses were found to be false-negative after core biopsy. After an intensive review of discordant FNAB results, the final false-negative rate was reduced to 1.1% (p-value = 0.025. The kappa coefficients for correlations between methods were 0.304 (p-value p-value p-value Conclusions Concurrent CNB and FNAB under ultrasound guidance can provide accurate preoperative diagnosis of breast lesions and provide important information for appropriate treatment. Identification of discordant results using careful radiological-histopathological correlation can reduce the false-negative rate.

  1. Ultrasonography-guided core needle biopsy for the thyroid nodule: does the procedure hold any benefit for the diagnosis when fine-needle aspiration cytology analysis shows inconclusive results?

    Science.gov (United States)

    Hahn, S Y; Han, B-K; Ko, E Y; Ko, E S

    2013-01-01

    Objective: We evaluated the diagnostic role of ultrasonography-guided core needle biopsy (CNB) according to ultrasonography features of thyroid nodules that had inconclusive ultrasonography-guided fine-needle aspiration (FNA) results. Methods: A total of 88 thyroid nodules in 88 patients who underwent ultrasonography-guided CNB because of previous inconclusive FNA results were evaluated. The patients were classified into three groups based on ultrasonography findings: Group A, which was suspicious for papillary thyroid carcinoma (PTC); Group B, which was suspicious for follicular (Hurthle cell) neoplasm; and Group C, which was suspicious for lymphoma. The final diagnoses of the thyroid nodules were determined by surgical confirmation or follow-up after ultrasonography-guided CNB. Results: Of the 88 nodules, the malignant rate was 49.1% in Group A, 12.0% in Group B and 90.0% in Group C. The rates of conclusive ultrasonography-guided CNB results after previous incomplete ultrasonography-guided FNA results were 96.2% in Group A, 64.0% in Group B and 90.0% in Group C (p=0.001). 12 cases with inconclusive ultrasonography-guided CNB results were finally diagnosed as 8 benign lesions, 3 PTCs and 1 lymphoma. The number of previous ultrasonography-guided FNA biopsies was not significantly different between the conclusive and the inconclusive result groups of ultrasonography-guided CNB (p=0.205). Conclusion: Ultrasonography-guided CNB has benefit for the diagnosis of thyroid nodules with inconclusive ultrasonography-guided FNA results. However, it is still not helpful for the differential diagnosis in 36% of nodules that are suspicious for follicular neoplasm seen on ultrasonography. Advances in knowledge: This study shows the diagnostic contribution of ultrasonography-guided CNB as an alternative to repeat ultrasonography-guided FNA or surgery. PMID:23564885

  2. Ultrasound-guided percutaneous needle electrolysis in chronic lateral epicondylitis: short-term and long-term results

    Science.gov (United States)

    Valera-Garrido, Fermín; Minaya-Muñoz, Francisco; Medina-Mirapeix, Francesc

    2014-01-01

    Background Ultrasound (US)-guided percutaneous needle electrolysis (PNE) is a novel minimally invasive approach which consists of the application of a galvanic current through an acupuncture needle. Objective To evaluate the clinical and ultrasonographic effectiveness of a multimodal programme (PNE, eccentric exercise (EccEx) and stretching) in the short term for patients with chronic lateral epicondylitis, and to determine whether the clinical outcomes achieved decline over time. Methods A one-way repeated measures study was performed in a clinical setting in 36 patients presenting with lateral epicondylitis. The patients received one session of US-guided PNE per week over 4–6 weeks, associated with a home programme of EccEx and stretching. The main outcome measures were severity of pain, disability (Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), structural tendon changes (US), hypervascularity and patients’ perceptions of overall outcome. Measurements at 6, 26 and 52 weeks follow-up included recurrence rates (increase in severity of pain or disability compared with discharge), perception of overall outcome and success rates. Results All outcome measures registered significant improvements between pre-intervention and discharge. Most patients (n=30, 83.3%) rated the overall outcome as ‘successful’ at 6 weeks. The ultrasonographic findings showed that the hypoechoic regions and hypervascularity of the extensor carpi radialis brevis changed significantly. At 26 and 52 weeks, all participants (n=32) perceived a ‘successful’ outcome. Recurrence rates were null after discharge and at follow-up at 6, 26 and 52 weeks. Conclusions Symptoms and degenerative structural changes of chronic lateral epicondylitis are reduced after US-guided PNE associated with EccEx and stretching, with encouragingly low recurrences in the mid to long term. Trial registration number ClinicalTrials.gov identifier: NCT02085928. PMID:25122629

  3. Learning curve of thyroid fine-needle aspiration biopsy.

    Science.gov (United States)

    Penín, Manuel; Martín, M Ángeles; San Millán, Beatriz; García, Juana

    2017-12-01

    Fine-needle aspiration biopsy (FNAB) is the reference procedure for thyroid nodule evaluation. Its main limitation are inadequate samples, which should be less than 20%. To analyze the learning curve of the procedure by comparing the results of a non-experienced endocrinologist (endocrinologist 2) to those of an experienced one (endocrinologist 1). Sixty FNABs were analyzed from February to June 2016. Each endocrinologist made 2punctures of every nodule in a random order. This order and the professional making every puncture were unknown to the pathologist who examined the samples. Endocrinologist 1 had a higher percentage of diagnoses than endocrinologist 2 (82% vs. 72%, P=.015). In the first 20 FNABs, the difference between both physicians was remarkable and statistically significant (80% vs. 50%, P=.047). In the following 20 FNABs, the difference narrowed and was not statistically significant (90% vs. 65%, P=.058). In the final 20 FNABs, the difference was minimal and not statistically significant (75% vs. 70%, P=.723). The learning curve of ultrasound-guided FNAB may be completed in a suitable environment by performing it at least 60 times. Although the guidelines recommend at least 3punctures per nodule, 2are enough to achieve an accurate percentage of diagnoses. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Incidental primary mediastinal choriocarcinoma diagnosed by endobronchial ultrasound-guided fine needle aspiration in a patient presenting with transient ischemic attack and stroke.

    Science.gov (United States)

    Francischetti, Ivo M B; Cajigas, Antonio; Suhrland, Mark; Farinhas, Joaquim M; Khader, Samer

    2017-08-01

    We describe a case of a 41-year old male patient with no significant prior medical history who presents with symptoms of Transient Ischemic Attack and stroke. Magnetic Resonance Imaging (MRI) of the brain identified areas of ischemia in the left side, and angiography showed occlusion of the left Medial Cerebral Artery (MCA). Cardiac Transthoracic Echocardiogram (TTE) for stroke evaluation incidentally noted a mediastinal abnormality leading to cancer work-up. Computer Tomography (CT) and 18 F-fluorodeoxyglucose (FDG) PET-CT scan of the chest incidentally revealed an avid 6 cm paraesophagial/subcarinal mass. Further diagnostic work-up with endoscopic and endobronchial ultra sound (EBUS)-guided fine needle aspiration (FNA) of the mass yielded a cytology diagnosis of Germ Cell Tumor (GCT), with choriocarcinoma component. Additionally, high plasma levels of β-human chorionic gonadotrophin (β-HCG) were detected with no evidence of testicular tumor. This exceedingly rare presentation for a primary mediastinal choriocarcinoma underscores the importance of complete investigation of young patients presenting with neurological symptoms compatible with ischemic events. Diagn. Cytopathol. 2017;45:738-743. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  5. Thyroid Nodule Classification in Ultrasound Images by Fine-Tuning Deep Convolutional Neural Network.

    Science.gov (United States)

    Chi, Jianning; Walia, Ekta; Babyn, Paul; Wang, Jimmy; Groot, Gary; Eramian, Mark

    2017-08-01

    With many thyroid nodules being incidentally detected, it is important to identify as many malignant nodules as possible while excluding those that are highly likely to be benign from fine needle aspiration (FNA) biopsies or surgeries. This paper presents a computer-aided diagnosis (CAD) system for classifying thyroid nodules in ultrasound images. We use deep learning approach to extract features from thyroid ultrasound images. Ultrasound images are pre-processed to calibrate their scale and remove the artifacts. A pre-trained GoogLeNet model is then fine-tuned using the pre-processed image samples which leads to superior feature extraction. The extracted features of the thyroid ultrasound images are sent to a Cost-sensitive Random Forest classifier to classify the images into "malignant" and "benign" cases. The experimental results show the proposed fine-tuned GoogLeNet model achieves excellent classification performance, attaining 98.29% classification accuracy, 99.10% sensitivity and 93.90% specificity for the images in an open access database (Pedraza et al. 16), while 96.34% classification accuracy, 86% sensitivity and 99% specificity for the images in our local health region database.

  6. Fine-needle aspiration findings of a rare hematopoietic neoplasm presenting as obstructive jaundice.

    Science.gov (United States)

    Tracht, Jessica; Ahmed, Ali M; Rosenblum Donath, Frida

    2017-12-01

    A 51-year-old female who presented with obstructive jaundice was found to have masses in the pancreatic head and tail as well as suspicious liver and periaortic masses on imaging. Aspiration cytology of the pancreatic tail mass showed abundant large single cells with vacuolated eosinophilic cytoplasm, marked nuclear pleomorphism, large bizarre irregular nuclei, binucleation, and prominent nucleoli. Numerous cells also showed intracytoplasmic black to brown pigmentation. A cell block was obtained and extensive immunohistochemical staining was performed. S-100, HMB-45, Sox10, pancytokeratin, CK7, RCC antigen, synaptophysin, HepPar 1, inhibin, CD45, CD21, and CD123 were negative, making melanoma, epithelial malignancies, lymphoma, follicular dendritic and plasmacytoid dendritic cell neoplasms less likely. CD4 and CD56 showed partial positivity, and CD68, CD163, and CD14 were positive, supporting the diagnosis of histiocytic sarcoma. Surgical specimens and immunohistochemistry confirmed the cytologic findings. Histiocytic sarcoma is a rare aggressive malignancy of histiocytic origin with most cases presenting in adults in extranodal sites, most commonly the intestinal tract. Few cases are reported in the literature, presenting diagnostic challenges for cytopathologists when seen on fine-needle aspiration. We present the first reported case of histiocytic sarcoma presenting as a pancreatic mass, diagnosed by endoscopic ultrasound guided fine-needle aspiration (EUS-FNA). This entity is rarely described on cytology and arose in a location in which EUS-FNA is the diagnostic modality of choice. This case study highlights that cytopathologists should be aware of histiocytic sarcoma occurring in extranodal locations accessible by EUS-FNA and be familiar with the cytomorphologic appearance. © 2017 Wiley Periodicals, Inc.

  7. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  8. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  9. Evolution of a rapid onsite evaluation (ROSE) service for endobronchial ultrasound guided (EBUS) fine needle aspiration (FNA) cytology in a UK Hospital: A 7 year audit.

    Science.gov (United States)

    Stevenson, Tracey; Powari, Manish; Bowles, Christopher

    2018-05-13

    Endobronchial ultrasound fine needle aspiration (EBUS FNA) is a well-established procedure for the diagnosis and staging of lung cancer. We review our provision of this service at the Royal Devon and Exeter NHS Foundation Trust and the role of rapid onsite evaluation (ROSE) with the increasing demand for molecular markers in this era of personalized medicine. A review of the changes in the Endoscopy clinic over the 7 years from the introduction of EBUS at the end of 2010 until 2017 was carried out. This included the availability of material obtained for diagnosis, accurate subtyping, and molecular testing. We also assessed the success of molecular genetics DNA techniques from EBUS material versus formalin fixed paraffin embedded tissue (FFPE). A total of 1218 EBUS cases with ROSE were reported between 2011 and 2017 Percentage diagnostic rates were calculated as 83, 82, 84, 92, 93, 94, and 92 for 2011, 2012, 2013, 2014, 2015, 2016, and 2017, respectively. Availability of material for immunocytochemistry ranged from 86 to 100% over the 7 years. Molecular testing was successfully performed for EGFR in 89-100% of requested cases and ALK testing in 87-100% of requested cases. EBUS sourced material gave on average twice the amount of DNA and fewer amplicon repeats per patient compared to FFPE material. ROSE at EBUS FNA provides access to suitable material for molecular testing with increased yields in the form of needle washings for EGFR with FFPE materials for ALK and PDL1 testing. © 2018 Wiley Periodicals, Inc.

  10. ultrasound-guided shoulder arthrogram injection

    African Journals Online (AJOL)

    2008-10-15

    Oct 15, 2008 ... Using an aseptic technique and without moving the ultrasound transducer from the desired transverse plane, the needle is advanced into the joint space through the rotator cuff interval, using real-time ultrasound guidance (Fig.2). The needle is inserted into the shoulder approximately midway between the ...

  11. Ultrasound diagnostics of thyroid diseases

    International Nuclear Information System (INIS)

    Kharchenko, Vladimir P.; Kotlyarov, Peter M.; Mogutov, Mikhail S.; Sencha, Alexander N.; Patrunov, Yury N.; Belyaev, Denis V.; Alexandrov, Yury K.

    2010-01-01

    This book is based on the authors' extensive practical experience in the use of modern ultrasound, and other radiological methods, in the diagnosis of thyroid diseases. The authors have analyzed more than 100,000 ultrasound examinations performed between 1995 and 2008 in patients with thyroid and parathyroid disease, as well as many thousands of diagnostic and therapeutic ultrasound-guided minimally invasive procedures. The opening chapters include discussion of current ultrasound techniques, pitfalls, and the specifics of ultrasound examination of the thyroid in children. Detailed attention is then devoted to findings in the normal thyroid and in the presence of diffuse and focal changes. Further chapters focus on such topics as ultrasound examination after thyroid surgery and ultrasound diagnosis of parathyroid disease, recurrent goiter, and neck masses. Ultrasound-guided minimally invasive techniques, such as fine-needle aspiration biopsy, percutaneous laser ablation, and ethanol and glucocorticoid injections, are considered in depth. This up-to-date and richly illustrated book will interest and assist specialists in ultrasound diagnostics, radiologists, endocrinologists, and neck surgeons. (orig.)

  12. Comparison of Fine Needle Aspiration and Fine Needle Nonaspiration Cytology of Thyroid Nodules: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Hongming Song

    2015-01-01

    Full Text Available Background. Fine needle aspiration cytology (FNAC and fine needle nonaspiration cytology (FNNAC are useful cost-effective techniques for preoperatively assessing thyroid lesions. Both techniques have advantages and disadvantages, and there is controversy over which method is superior. This meta-analysis was performed to evaluate the differences between FNAC and FNNAC for diagnosis of thyroid nodules. Methods. Primary publications were independently collected by two reviewers from PubMed, Web of Science, Google Scholar, EBSCO, OALib, and the Cochrane Library databases. The following search terms were used: fine needle, aspiration, capillary, nonaspiration, sampling without aspiration, thyroid, and cytology. The last search was performed on February 1, 2015. Results. Sixteen studies comprising 1,842 patients and 2,221 samples were included in this study. No statistically significant difference was observed between FNAC and FNNAC groups with respect to diagnostically inadequate smears, diagnostically superior smears, diagnostic performance (accuracy, sensitivity, specificity, negative predictive value, and positive predictive value, area under the summary receiver operating characteristic curve, average score of each parameter (background blood or clot, amount of cellular material, degree of cellular degeneration, degree of cellular trauma, and retention of appropriate architecture, and total score of five parameters. Conclusion. FNAC and FNNAC are equally useful in assessing thyroid nodules.

  13. A review of the benefits and pitfalls of phantoms in ultrasound-guided regional anesthesia.

    Science.gov (United States)

    Hocking, Graham; Hebard, Simon; Mitchell, Christopher H

    2011-01-01

    With the growth of ultrasound-guided regional anesthesia, so has the requirement for training tools to practice needle guidance skills and evaluate echogenic needles. Ethically, skills in ultrasound-guided needle placement should be gained in a phantom before performance of nerve blocks on patients in clinical practice. However, phantom technology is varied, and critical evaluation of the images is needed to understand their application to clinical use. Needle visibility depends on the echogenicity of the needle relative to the echogenicity of the tissue adjacent the needle. We demonstrate this point using images of echogenic and nonechogenic needles in 5 different phantoms at both shallow angles (20 degrees) and steep angles (45 degrees). The echogenicity of phantoms varies enormously, and this impacts on how needles are visualized. Water is anechoic, making all needles highly visible, but does not fix the needle to allow practice placement. Gelatin phantoms and Blue Phantoms provide tactile feedback but have very low background echogenicity, which greatly exaggerates needle visibility. This makes skill acquisition easier but can lead to false confidence in regard to clinical ability. Fresh-frozen cadavers retain much of the textural feel of live human tissue and are nearly as echogenic. Similar to clinical practice, this makes needles inserted at steep angles practically invisible, unless they are highly echogenic. This review describes the uses and pitfalls of phantoms that have been described or commercially produced. Copyright © 2011 by American Society of Regional Anesthesia and Pain Medicine

  14. Metastatic Chordoma: A Diagnostic Challenge on Fine Needle Aspiration

    Directory of Open Access Journals (Sweden)

    Ghassan Tranesh

    2016-01-01

    Full Text Available Chordomas are primary low grade malignant tumors of bone that usually arise within both ends of axial skeleton. The Notochord is a midline, ectoderm-derived structure that defines the phylum of chordates. Chordomas may pose difficult diagnostic challenges when encountered in secondary locations, such as lungs or other parenchymatous organs. We report the cytologic findings of a metastatic chordoma sampled through CT-scan guided fine needle aspiration (FNA of lower lobe lung nodule in a 54-year-old man diagnosed with recurrent chordoma involving the lumber spine and paraspinal region.

  15. Ultrasound-guided central venous access using Google Glass.

    Science.gov (United States)

    Wu, Teresa S; Dameff, Christian J; Tully, Jeffrey L

    2014-12-01

    The use of ultrasound during invasive bedside procedures is quickly becoming the standard of care. Ultrasound machine placement during procedures often requires the practitioner to turn their head during the procedure to view the screen. Such turning has been implicated in unintentional hand movements in novices. Google Glass is a head-mounted computer with a specialized screen capable of projecting images and video into the view of the wearer. Such technology may help decrease unintentional hand movements. Our aim was to evaluate whether or not medical practitioners at various levels of training could use Google Glass to perform an ultrasound-guided procedure, and to explore potential advantages of this technology. Forty participants of varying training levels were randomized into two groups. One group used Google Glass to perform an ultrasound-guided central line. The other group used traditional ultrasound during the procedure. Video recordings of eye and hand movements were analyzed. All participants from both groups were able to complete the procedure without difficulty. Google Glass wearers took longer to perform the procedure at all training levels (medical student year 1 [MS1]: 193 s vs. 77 s, p > 0.5; MS4: 197s vs. 91s, p ≤ 0.05; postgraduate year 1 [PGY1]: 288s vs. 125 s, p > 0.5; PGY3: 151 s vs. 52 s, p ≤ 0.05), and required more needle redirections (MS1: 4.4 vs. 2.0, p > 0.5; MS4: 4.8 vs. 2.8, p > 0.5; PGY1: 4.4 vs. 2.8, p > 0.5; PGY3: 2.0 vs. 1.0, p > 0.5). In this study, it was possible to perform ultrasound-guided procedures with Google Glass. Google Glass wearers, on average, took longer to gain access, and had more needle redirections, but less head movements were noted. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. CT Scan-Guided Abrams' Needle Pleural Biopsy versus Ultrasound-Assisted Cutting Needle Pleural Biopsy for Diagnosis in Patients with Pleural Effusion: A Randomized, Controlled Trial.

    Science.gov (United States)

    Metintas, Muzaffer; Yildirim, Huseyin; Kaya, Tamer; Ak, Guntulu; Dundar, Emine; Ozkan, Ragip; Metintas, Selma

    2016-01-01

    Image-guided pleural biopsies, both using ultrasound (US) or computed tomography (CT), are important in the diagnosis of pleural disease. However, no consensus exists regarding which biopsy needles are appropriate for specific procedures. In this randomized, prospective study, we aimed to compare CT scan-guided pleural biopsy using an Abrams' needle (CT-ANPB) with US-assisted pleural biopsy using a cutting needle (US-CNPB) with respect to both diagnostic yield and safety. Between February 2009 and April 2013, 150 patients with exudative pleural effusion who could not be diagnosed by cytological analysis were included in the study. The patients were randomized into either the US-CNPB group or the CT-ANPB group. The two groups were compared in terms of diagnostic sensitivity and complications. Of the 150 patients enrolled in this study, 45 were diagnosed with malignant mesothelioma, 46 were diagnosed with metastatic pleural disease, 18 were diagnosed with pleural tuberculosis, 34 were diagnosed with benign pleural disease, and 7 were lost to follow-up. In the US-CNPB group, the diagnostic sensitivity was 66.7%, compared with 82.4% in the CT-ANPB group; the difference between the two groups was statistically significant (p = 0.029). The sensitivity of CT-ANPB increased to 93.7% for patients with a pleural thickness ≥1 cm. The complication rates were low and acceptable. The first diagnostic intervention that should be preferred in patients with pleural effusion and associated pleural thickening on a CT scan is CT-ANPB. US-CNPB should be used primarily in cases for which only pleural thickening but no pleural effusion is noted. © 2016 S. Karger AG, Basel.

  17. Ultrasound-guided genitourinary interventions: principles and techniques

    Directory of Open Access Journals (Sweden)

    Byung Kwan Park

    2017-10-01

    Full Text Available Ultrasound (US is often used to guide various interventional procedures in the genitourinary (GU tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  18. Ultrasound-guided genitourinary interventions: principles and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Kwan [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    Ultrasound (US) is often used to guide various interventional procedures in the genitourinary (GU) tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  19. Enhanced Visualization of Fine Needles Under Sonographic Guidance Using a MEMS Actuator

    Directory of Open Access Journals (Sweden)

    Zhiyuan Shen

    2015-01-01

    Full Text Available Localization of a needle tip is important for biopsy examinations in clinics. However, the needle tip is sometimes difficult to discern under the guidance of sonography due to its poor visibility. A mini actuator that radiates a low-intensity ultrasound wave was manufactured using micro-electro-mechanical system (MEMS technology. Interference between the radiated and diagnostic ultrasound pulses was observed as bright lines in the B-mode ultrasound image, from which the mini actuator could be recognized with ease. Because the distance between the mini actuator and the needle tip is fixed, the needle tip can be determined despite its inconsistent appearance in the sonography. Both gel phantom and ex vivo tissue evaluation showed that the needle tip can be determined reliably utilizing the acoustic interference pattern.

  20. Percutaneous image-guided needle biopsy in children - summary of our experience with 57 children

    International Nuclear Information System (INIS)

    Sklair-Levy, M.; Lebensart, P.D.; Applbaum, Y.H.; Bar-Ziv, J.; Libson, E.; Ramu, N.; Freeman, A.; Gozal, D.; Gross, E.; Sherman, Y.

    2001-01-01

    Background: Percutaneous image-guided needle biopsy in children has been slower to gain acceptance than in adults where it is regarded as the standard clinical practice in screening suspicious masses. Objectives: To report our experience with percutaneous image-guided needle biopsy in the pediatric population and assess its clinical use, efficacy and limitations. Material and methods: Sixty-nine percutaneous image-guided needle biopsies were performed in 57 children. The age of the children ranged from 4 days to 14 years (mean 5.6 years). We used 16- to-20-gauge cutting-edge needles. Sixty-two biopsies were core-needle biopsies and 7 fine-needle aspiration biopsies. Results: There were 50 malignant lesions, 10 benign lesions and 2 infectious lesions. In 55 (88.7 %) lesions the needle biopsy was diagnostic. In 7 (11.3 %) the biopsy was non-diagnostic and the diagnosis was made by surgery. Core-needle biopsy was diagnostic in 47 of 50 (94 %) of the malignant solid tumors. In 3 out of 5 children with lymphoma, an accurate diagnosis was obtained with needle aspiration. Seven children underwent a repeated core-needle biopsy, (5 for Wilms' tumor and 2 for neuroblastoma) that was diagnostic in all cases. All the biopsies were performed without complications. Conclusion: Percutaneous image-guided needle biopsy is a simple, minimally invasive, safe and accurate method for the evaluation of children with suspicious masses. These data suggest that image-guided needle biopsy is an excellent tool for diagnosing solid tumors in the pediatric population. Negative studies should be considered nondiagnostic and followed by excisional surgical biopsies when clinical suspicion of malignancy is high. (orig.)

  1. Real-time ultrasound-guided spinal anaesthesia: a prospective observational study of a new approach.

    LENUS (Irish Health Repository)

    Conroy, P H

    2013-01-01

    Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1-6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83-4.1) demonstrating the feasibility of this technique in routine clinical practice.

  2. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    Science.gov (United States)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  3. Ultrasound screening of thyroid nodules in adults with no previous exposed to irradiation comparison between scanning, palpation and fine needle aspiration cytology. A study in Ghaem Hospital, Mashhad, North East of Iran

    International Nuclear Information System (INIS)

    Rahrouh, M.; Namadanian, G.R.; Zakavi, S.R.; Rezaei, H.

    2003-01-01

    There are a great number of studies on the association between childhood radiation exposure and thyroid nodules and cancer. Ultrasound imaging of thyroid nodules is valuable part of diagnostics and identifies abnormalities, because ultrasound can detect nodules as small as 2-3 mm and no radiation is involved , it has gained wide acceptance for the screening of nodular thyroid disease. 500 subjects were selected randomly from medical students in university of medical sciences in Mashhad North East of Iran. Individuals were screened by a health survey , thyroid ultrasounds, 99mTc-pertechnetate scans, palpation and fine needle aspiration obtained as necessary. The ultrasound was performed with a 7.5-MHz transducer in direct contact with the lubricated skin of the extended neck. Each ultrasound exam was read independently by two radiologists and one endocrinologist. Each nodule was characterized as follows: 1) presence; 2) size ; 3) location; ant or post; 4) location; upper pole, midportion of lobe, lower pole, or isthmus; and 5) type; solid, cystic, or mixed. In 500 cases (312 men, 188 women; age range, 18 - 30 years) underwent neck sonography. Normal findings were verified by clinical follow-up and thyroid disease was found in (5%) of subjectes. A total of 25 certain thyroid nodules were detected by the ultrasound examinations. Eighty eight percent nodules were less than 1.0 cm dimension.Among the subjects who had them thyroid nodules,(48%) were cystic , (44%) were hypoechoic lesions and (8 %) were hyperechoic .The abnormality of thyroid echo was solitary in (1,8%) ,multiple in (1,4%) and diffuse in (0,6%) of subjectes. All abnormal findings were verified by fine needle aspiration biopsy and correlated with thyroid scan, and surgery. The results reported here can be compared to several reports on the prevalence of ultrasound detected thyroid nodules in adult populations not exposed to radiation .The major advantage is that ultrasound can find clinically important

  4. Ultrasound-guided sacroiliac joint injection technique.

    LENUS (Irish Health Repository)

    Harmon, Dominic

    2008-07-01

    We describe a case report and technique for using a portable ultrasound scanner and a curvilinear transducer (4-5MHz) (SonoSite Micromaxx SonoSite, Inc. 21919 30th Drive SE Bothwell W. A.) to guide sacroiliac joint (SIJ) injection. A 42-year-old male presented with chronic lower back pain centered on his left SIJ. His pain averaged 7 out of 10 (numerical rating scale). For the ultrasound-guided SIJ injection the patient was placed in the prone position. The ultrasound transducer was oriented in a transverse orientation at the level of the sacral hiatus. Here the sacral cornuae were identified. Moving the transducer laterally from here, the lateral edge of the sacrum was identified. This bony edge was followed in a cephalad direction with the transducer maintained in a transverse orientation. A second bony contour, the ileum, was identified. The cleft between both bony contours represented the sacroiliac joint. This was found at 4.5 cm depth. Real-time imaging was used to direct a 22G spinal needle into the SIJ, where solution was injected under direct vision. The patient\\'s pain intensity decreased to a 2 out of 10 (numerical rating scale). Function improved and the patient was able to return to work. These improvements were maintained at 16 weeks. Ultrasound guidance does not expose patients and personnel to radiation and is readily accessible. Ultrasound-guided SIJ injections may have particular applications in the management of chronic lower back pain in certain clinical scenarios (e.g. pregnancy). Future studies to demonstrate efficacy and reproducibility are needed.

  5. Needle path planning and steering in a three-dimensional non-static environment using two-dimensional ultrasound images

    Science.gov (United States)

    Vrooijink, Gustaaf J.; Abayazid, Momen; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak

    2015-01-01

    Needle insertion is commonly performed in minimally invasive medical procedures such as biopsy and radiation cancer treatment. During such procedures, accurate needle tip placement is critical for correct diagnosis or successful treatment. Accurate placement of the needle tip inside tissue is challenging, especially when the target moves and anatomical obstacles must be avoided. We develop a needle steering system capable of autonomously and accurately guiding a steerable needle using two-dimensional (2D) ultrasound images. The needle is steered to a moving target while avoiding moving obstacles in a three-dimensional (3D) non-static environment. Using a 2D ultrasound imaging device, our system accurately tracks the needle tip motion in 3D space in order to estimate the tip pose. The needle tip pose is used by a rapidly exploring random tree-based motion planner to compute a feasible needle path to the target. The motion planner is sufficiently fast such that replanning can be performed repeatedly in a closed-loop manner. This enables the system to correct for perturbations in needle motion, and movement in obstacle and target locations. Our needle steering experiments in a soft-tissue phantom achieves maximum targeting errors of 0.86 ± 0.35 mm (without obstacles) and 2.16 ± 0.88 mm (with a moving obstacle). PMID:26279600

  6. Fine Needle Aspiration Biopsy in a Rural Family Practice

    African Journals Online (AJOL)

    ultrasound scan. A 21-gauge 1½-inch or 23-gauge 1¼-inch needle, attached to a 10-mL disposable plastic syringe, was used for FNAB of superficial masses. For percutaneous FNAB of deep-seated organs and masses, a 23 gauge 1¼-inch needle or 3½-inch spinal needle was used. The aspirate was spread on slides and ...

  7. Tracheobronchial puncture-site nodular reaction (TPNR following endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA: Systematic review of case reports

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2017-01-01

    Full Text Available Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA is a minimally invasive and efficacious diagnostic modality for lung cancer staging and evaluation of undiagnosed mediastinal lymphadenopathy. Procedure-related complications are uncommon. We herein report an infrequently described phenomenon following EBUS-TBNA in which two patients developed nodular granulation tissue at the tracheobronchial puncture site. On systematic review, we found description of such phenomena by terminologies such as endobronchial inflammatory polyp, granuloma, and endobronchial mass. The endobronchial inflammatory polyp has been one of the most commonly used terminologies for these; but in most cases, the classical features of an inflammatory polyp are lacking. We propose the term, tracheobronchial puncture-site nodular reaction (TPNR with further classification into granulomatous and nongranulomatous subtypes, for standardized reporting of such reactions following transbronchial needle aspiration procedures. Knowledge of this entity and standardized nomenclature shall help in better characterization of the outcomes and risk factors for the occurrence of these reactions.

  8. Characterization of ultrasound elevation beamwidth artifacts for prostate brachytherapy needle insertion

    International Nuclear Information System (INIS)

    Peikari, Mohammad; Chen, Thomas Kuriran; Lasso, Anras; Heffter, Tamas; Fichtinger, Gabor; Burdette, Everette C.

    2012-01-01

    Purpose: Ultrasound elevation beamwidth leads to image artifacts and uncertainties in localizing objects (such as a surgical needle) in ultrasound images. The authors examined the clinical significance of errors caused by elevation beamwidth artifacts and imaging parameters in needle insertion procedures. Methods: Beveled prostate brachytherapy needles were inserted through all holes of a grid template under real-time transrectal ultrasound (TRUS) guidance. The needle tip position as indicated by the TRUS image was compared to their observed physical location. A new device was developed to measure the ultrasound elevation beamwidth. Results: Imaging parameters of the TRUS scanner have direct impact on the localization error ranging from 0.5 up to 4 mm. The smallest localization error was observed laterally close to the center of the grid template and axially within the beam's focal zone. Largest localization error occurs laterally around both sides of the grid template and axially within the beam's far field. The authors also found that the localization errors vary with both lateral and elevation offsets. Conclusions: The authors found properly adjusting the TRUS imaging settings to lower the ultrasound gain and power effectively minimized the appearance of elevation beamwidth artifacts and in turn reduced the localization errors of the needle tip.

  9. Imaging of implant needles for real-time HDR-brachytherapy prostate treatment using biplane ultrasound transducers.

    Science.gov (United States)

    Siebert, Frank-André; Hirt, Markus; Niehoff, Peter; Kovács, György

    2009-08-01

    Ultrasound imaging is becoming increasingly important in prostate brachytherapy. In high-dose-rate (HDR) real-time planning procedures the definition of the implant needles is often performed by transrectal ultrasound. This article describes absolute measurements of the visibility and accuracy of manual detection of implant needle tips and compares measurement results of different biplane ultrasound systems in transversal and longitudinal (i.e., sagittal) ultrasound modes. To obtain a fixed coordinate system and stable conditions the measurements were carried out in a water tank using a dedicated marker system. Needles were manually placed in the phantom until the observer decided by the real-time ultrasound image that the zero position was reached. A comparison of three different ultrasound systems yielded an offset between 0.8 and 3.1 mm for manual detection of the needle tip in ultrasound images by one observer. The direction of the offset was discovered to be in the proximal direction, i.e., the actual needle position was located more distally compared to the ultrasound-based definition. In the second part of the study, the ultrasound anisotropy of trocar implant needles is reported. It was shown that the integrated optical density in a region of interest around the needle tip changes with needle rotation. Three peaks were observed with a phase angle of 120 degrees. Peaks appear not only in transversal but also in longitudinal ultrasound images, with a phase shift of 60 degrees. The third section of this study shows results of observer dependent influences on needle tip detection in sagittal ultrasound images considering needle rotation. These experiments were carried out using the marker system in a water tank. The needle tip was placed exactly at the position z=0 mm. It was found that different users tend to differently interpret the same ultrasound images. The needle tip was manually detected five times in the ultrasound images by three experienced observers

  10. A rare constellation of empyema, lung abscess, and mediastinal abscess as a complication of endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Huang, Chun-Ta; Chen, Chung-Yu; Ho, Chao-Chi; Yu, Chong-Jen

    2011-07-01

    The introduction of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) brought about significant advancement in the field of bronchoscopy. The major indications for EBUS-TBNA are lung cancer staging and diagnosis of mediastinal lymphadenopathy. This procedure is minimally invasive and cost saving, and no complications have been described in large-scale studies. In this report, we present a case of empyema, lung abscess, and mediastinal abscess that developed in a patient undergoing EBUS-TBNA; the patient subsequently recovered uneventfully after aggressive surgical debridement and antimicrobial therapy. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  11. An estimation of the minimum effective anesthetic volume of 2% lidocaine in ultrasound-guided axillary brachial plexus block.

    LENUS (Irish Health Repository)

    O'Donnell, Brian D

    2009-07-01

    Ultrasound guidance facilitates precise needle and injectate placement, increasing axillary block success rates, reducing onset times, and permitting local anesthetic dose reduction. The minimum effective volume of local anesthetic in ultrasound-guided axillary brachial plexus block is unknown. The authors performed a study to estimate the minimum effective anesthetic volume of 2% lidocaine with 1:200,000 epinephrine (2% LidoEpi) in ultrasound-guided axillary brachial plexus block.

  12. Image guided percutaneous splenic interventions

    International Nuclear Information System (INIS)

    Kang, Mandeep; Kalra, Naveen; Gulati, Madhu; Lal, Anupam; Kochhar, Rohit; Rajwanshi, Arvind

    2007-01-01

    Aim: The objective of this study is to evaluate the efficacy and safety of image-guided percutaneous splenic interventions as diagnostic or therapeutic procedures. Materials and methods: We performed a retrospective review of our interventional records from July 2001 to June 2006. Ninety-five image-guided percutaneous splenic interventions were performed after informed consent in 89 patients: 64 men and 25 women who ranged in age from 5 months to 71 years (mean, 38.4 years) under ultrasound (n = 93) or CT (n = 2) guidance. The procedures performed were fine needle aspiration biopsy of focal splenic lesions (n = 78) and aspiration (n = 10) or percutaneous catheter drainage of a splenic abscess (n = 7). Results: Splenic fine needle aspiration biopsy was successful in 62 (83.78%) of 74 patients with benign lesions diagnosed in 43 (58.1%) and malignancy in 19 (25.67%) patients. The most common pathologies included tuberculosis (26 patients, 35.13%) and lymphoma (14 patients, 18.91%). Therapeutic aspiration or pigtail catheter drainage was successful in all (100%) patients. There were no major complications. Conclusions: Image-guided splenic fine needle aspiration biopsy is a safe and accurate technique that can provide a definitive diagnosis in most patients with focal lesions in the spleen. This study also suggests that image-guided percutaneous aspiration or catheter drainage of splenic abscesses is a safe and effective alternative to surgery

  13. Diagnostic accuracy of fine needle biopsy in the management of thyroid pathology in the Hospital Mexico in 2011-2012

    International Nuclear Information System (INIS)

    Elizondo Herrera, Luis Guillermo

    2013-01-01

    The nodule has been a very common thyroid pathology; through palpation is located in a 5% of the population and through ultrasound this figure has increased by almost 50%. The thyroid nodule has been the shape of presentation of thyroid cancer; the majority of times asymptomatic and most recently has shown without relation to the size of the nodule, 5 to 15% of thyroid nodules are malignant. This requires to classify clinically, to decide which patient requires surgical management. In Costa Rica, and especially in the CCSS (Caja Costarricense de Seguro Social); It has had two tools for perform differentiation: ultrasound and FNA (fine needle aspiration biopsy). The diagnostic accuracy of these tests has allowed minimize thyroid surgeries in patients with benign nodules and sift patients with thyroid nodules into search for cancer of thyroid. Previous to routine use of FNA was resected only 14% of malignant nodules, now are resected more than 50%. The diagnostic accuracy of these tests is related to technical aspects and also with the structural and histological features of the lesions valued. The limitations and scope described have allowed to optimize the utilization of direct and indirect costs related to the management of patients with thyroid nodules and decrease morbidity in the management of thyroid pathology. The sensitivity and specificity of fine needle biopsy varies, as is noted in various publications, according to the reference center, has been quite reliable between 0.3 and 3 cm and is highly specific in the case of papillary carcinoma. The diagnostic accuracy of the test has never been studied in the Hospital Mexico. Of the total population for the period 2011-2012, it is documented that the FNA is a study of high specificity (95,5%), with value predictive negative and positive appropriate (>75%) and with an intermediate sensitivity (55,6%). The analysis of ultrasound and FNA as parallel testing has allowed greater sensitivity. The use of ultrasound

  14. Fine needle aspiration diagnosis of a spontaneously infarcted fibroadenoma mimicking carcinoma: a case report.

    Science.gov (United States)

    Arora, Rajan; Abou-Bakr, Amany; Al Taleb, Ahmed

    2013-02-01

    Spontaneous infarction of fibroadenoma is an extremely rare complication in a nonpregnant/nonlactating female undergoing first-time aspiration. It can be misdiagnosed as carcinoma in all aspects of triple approach used for evaluation of patients with breast lesions. A 37-year-old woman presented to the outpatient surgical clinic with a 6-month history of a breast lump that was slowly increasing in size and had become painful during the past month. There was no history of any trauma or fine needle aspiration, and she was not pregnant or lactating. Mammogram and ultrasound revealed a 2.9-cm heterogenous hypoechoic suspicious lesion. No lymph nodes were detected in the axilla. Fine needle aspiration cytology was performed, and a diagnosis of benign breast lesion with features of infarction was rendered on cytology. The lump was excised surgically, and a histological diagnosis of infarcted fibroadenoma was made. Careful and diligent search for preserved benign epithelial cells on smears is the key to recognize this entity and avoid serious therapeutic implications.

  15. Ultrasound-Guided Intervention for Treatment of Trigeminal Neuralgia: An Updated Review of Anatomy and Techniques

    Directory of Open Access Journals (Sweden)

    Abdallah El-Sayed Allam

    2018-01-01

    Full Text Available Orofacial myofascial pain is prevalent and most often results from entrapment of branches of the trigeminal nerves. It is challenging to inject branches of the trigeminal nerve, a large portion of which are shielded by the facial bones. Bony landmarks of the cranium serve as important guides for palpation-guided injections and can be delineated using ultrasound. Ultrasound also provides real-time images of the adjacent muscles and accompanying arteries and can be used to guide the needle to the target region. Most importantly, ultrasound guidance significantly reduces the risk of collateral injury to vital neurovascular structures. In this review, we aimed to summarize the regional anatomy and ultrasound-guided injection techniques for the trigeminal nerve and its branches, including the supraorbital, infraorbital, mental, auriculotemporal, maxillary, and mandibular nerves.

  16. Ultrasound-guided image fusion with computed tomography and magnetic resonance imaging. Clinical utility for imaging and interventional diagnostics of hepatic lesions

    International Nuclear Information System (INIS)

    Clevert, D.A.; Helck, A.; Paprottka, P.M.; Trumm, C.; Reiser, M.F.; Zengel, P.

    2012-01-01

    Abdominal ultrasound is often the first-line imaging modality for assessing focal liver lesions. Due to various new ultrasound techniques, such as image fusion, global positioning system (GPS) tracking and needle tracking guided biopsy, abdominal ultrasound now has great potential regarding detection, characterization and treatment of focal liver lesions. Furthermore, these new techniques will help to improve the clinical management of patients before and during interventional procedures. This article presents the principle and clinical impact of recently developed techniques in the field of ultrasound, e.g. image fusion, GPS tracking and needle tracking guided biopsy and discusses the results based on a feasibility study on 20 patients with focal hepatic lesions. (orig.) [de

  17. Comparison of a novel real-time SonixGPS needle-tracking ultrasound technique with traditional ultrasound for vascular access in a phantom gel model.

    Science.gov (United States)

    Kopac, Daniel S; Chen, Jerry; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    Ultrasound-guided percutaneous vascular access for endovascular procedures is well established in surgical practice. Despite this, rates of complications from venous and arterial access procedures remain a significant cause of morbidity. We hypothesized that the use of a new technique of vascular access using an ultrasound with a novel needle-guidance positioning system (GPS) would lead to improved success rates of vascular puncture for both in-plane and out-of-plane techniques compared with traditional ultrasound. A prospective, randomized crossover study of medical students from all years of medical school was conducted using a phantom gel model. Each medical student performed three ultrasound-guided punctures with each of the four modalities (in-plane no GPS, in-plane with GPS, out-of-plane no GPS, out-of-plane with GPS) for a total of 12 attempts. The success or failure was judged by the ability to aspirate a simulated blood solution from the model. The time to successful puncture was also recorded. A poststudy validated NASA Task Load Index workload questionnaire was conducted to assess the student's perceptions of the two different techniques. A total of 30 students completed the study. There was no significant difference seen in the mean times of vascular access for each of the modalities. Higher success rates for vascular access using the GPS for both the in-plane (94% vs 91%) and the out-of-plane (86% vs 70%) views were observed; however, this was not statistically significant. The students perceived the mental demand (median 12.0 vs 14.00; P = .035) and effort to be lower (mean 11.25 vs 14.00; P = .044) as well as the performance to be higher (mean 15.50 vs 14.00; P = .041) for the GPS vs the traditional ultrasound-guided technique. Students also perceived their ability to access vessels increased with the aid of the GPS (7.00 vs 6.50; P = .007). The majority of students expressed a preference for GPS (26/30, 87%) as opposed to the traditional counterpart

  18. Should fine needle aspiration cytology in breast assessment be abandoned?

    International Nuclear Information System (INIS)

    Litherland, Janet C.

    2002-01-01

    Fine needle aspiration cytology (FNAC) has been used extensively in the U.K. for the diagnosis of breast lesions over the past 15 years. More recently, large gauge needle biopsy has been used to address many of the problems which have been encountered with fine needle aspiration. This paper reviews the evolution of the use of these procedures and the advantages and disadvantages of each. In considering whether to abandon the use of fine needle aspiration cytology in breast assessment, each individual unit should make a decision based upon their own audited results. However, even if FNAC is retained, it is important to be able to complement cytological diagnosis with core biopsy as there are indisputable advantages, e.g. in the diagnosis of mammographically detected microcalcification. As always, a multi-disciplinary approach is ultimately essential for effective patient management. Litherland, J.C. (2002)

  19. Diagnostic accuracy of fine needle aspiration cytology in hepatic tumours

    International Nuclear Information System (INIS)

    Nazir, R.T.; Sharif, M.A.; Iqbal, M.; Amin, M.S.

    2010-01-01

    To determine the diagnostic accuracy of fine-needle aspiration cytology (FNAC) in liver masses to isolate malignant from benign tumours and hepatocellular carcinoma (HCC) from metastatic tumours. Study Design: Cross-sectional, observational. Place and Duration of Study: Department of Histopathology, Combined Military Hospital, Peshawar, from June 2004 to June 2005. Methodology: All the patients with liver masses confirmed by ultrasonography, irrespective of age and gender, were included. Patients with inflammatory lesions were excluded from the study. Selected patients underwent fine-needle aspiration under ultrasound guidance followed by needle biopsy. The cytological slides were stained by haematoxylin and eosin (H and E) stain, while Papanicolaou's stain was employed in selective cases. Needle biopsy fragments were fixed in formalin followed by paraffin embedding and staining with H and E stain. Sensitivity and specificity of FNAC in the diagnosis of liver masses was determined using histological diagnosis on liver biopsy as gold standard. Results: There were one hundred subjects. The mean age at presentation was 55 +- 12 years with male to female ratio of 1.7:1. Cytological diagnosis in 19 cases was benign/non-neoplastic and 81 was malignant. Out of the latter, 49 (60.49%) were HCC and 32 (39.51%) were metastatic tumours on cytology. The overall sensitivity, specificity and accuracy of FNAC in the diagnosis of malignant lesions was 95.2%, 100% and 96% respectively using histological diagnosis on liver biopsy as gold standard. Sensitivity of FNAC to differentiate HCC from metastatic tumours in liver was 96% while specificity was 100% having a diagnostic accuracy of 97.5%. The discrepancy in cyto-histological comparison was mainly seen in well differentiated and poorly-differentiated HCCs. Conclusion: FNAC of the liver masses is a simple, safe, accurate, economical screening test without significant morbidity that can be used to identify the vast majority of

  20. Endobronchial ultrasound-guided transbronchial needle aspiration is a sensitive method to evaluate patients who should not undergo pulmonary metastasectomy†

    DEFF Research Database (Denmark)

    Eckardt, Jens; Licht, Peter Bjørn

    2015-01-01

    metastasectomy with systematic sampling of mediastinal lymph nodes for histological evaluation. RESULTS: One hundred and three eligible patients were referred for EBUS-TBNA during a 4-year period. The primary cancers were located in the colon/rectum (n = 64), kidney (n = 16) and other sites (n = 23). EBUS......OBJECTIVES: Pulmonary metastasectomy is considered an effective treatment in selected patients with extrapulmonary cancer and oligometastatic disease. We know that the presence of mediastinal lymph node metastases reduces survival significantly, but the mediastinum is rarely evaluated before...... metastasectomy in these patients. We prospectively evaluated how endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) could identify metastases to the mediastinal lymph nodes in patients referred for pulmonary metastasectomy. METHODS: All patients with extrapulmonary cancer...

  1. Diagnose of the prostate cancer: Utility of the antigen specifies of prostate, transrectal echography and aspired by fine needle

    International Nuclear Information System (INIS)

    De Nubbila, Eduardo; Rosillo, Marco; Fals, Orlando

    1993-01-01

    We describe three improved methods of detecting prostate cancer while it is still confined to the gland: Prostrate specific antigen (PSA), trans-rectal ultrasound (TRUS) and trans-rectal ultrasound-directed prostatic fine needle aspirate (TRFNA). Of a total of 60 studied cases, 23 cytological procedures were done, and half of these were found to have prostate cancer. We compare traditional methods like digital rectal examination and prostatic phosphatase acid with PSA and TRFNA. We conclude that these methods increase the sensibility and specificity of early prostate cancer detection

  2. Risks and benefits in treatment of mediastinal abscess by endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Tian, Lei; Krimsky, William S; Wu, Qingchen; Sun, Jiayuan

    2017-07-01

    Mediastinal abscess is a fatal condition, treatment of mediastinal abscess is with antibiotics and sometimes surgery for debridement and drainage. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a safe assessment and candidate treatment method of mediastinal lesions. This study aimed to HYPERLINK "javascript:void(0);" discuss risks and benefits in treatment of mediastinal abscess by EBUS-TBNA. We noticed a 56-year-old man with developed bilateral pneumonia and sepsis after puncture of mediastinal abscess by EBUS-TBNA. The patient was successfully treated with a combination of systemic anti-infection treatment and intracavitary administration of antibiotics, antifungal and repeated drainage and lavage via EBUS-TBNA, in 1 year follow-up without recurrence. This study indicated infection spread risk of mediastinal abscess after EBUS-TBNA, and mediastinal abscess was successfully cured by combination of systemic anti-infection and local intervention through EBUS-TBNA. EBUS-TBNA is a potential effective minimally invasive treatment for mediastinal abscess, and it is necessary to be aware of clinical complications after puncture of mediastinal infectious lesions by EBUS-TBNA. © 2015 John Wiley & Sons Ltd.

  3. Endobronchial Ultrasound Guided Transbronchial Needle Aspiration (ebus-tbna) for Diagnosis of Mediastinal and Hilar Masses

    International Nuclear Information System (INIS)

    Fatima, M.; Jamal, S.; Khan, M.A.; Ansari, J.K.; Ullah, M.U.

    2016-01-01

    Objective: To determine the sensitivity, specificity, negative and positive predictive values, and diagnostic accuracy of Endobronchial Ultrasound Guided Transbronchial Needle Aspiration (EBUS-TBNA). Study Design: Across-sectional validation study. Place and Duration of Study: Department of Histopathology, Army Medical College, in collaboration with Department of Pulmonology, Military Hospital Rawalpindi, from March 2014 to March 2015. Methodology: Cases of EBUS-TBNAcomprised of both TBNAs and cell block/biopsy of the same patients. Diagnosis was made on the TBNAslides and cell block/biopsy material. Taking biopsy/cell block as the gold standard, the data was analysed to calculate the sensitivity, specificity, negative and positive predictive values, and diagnostic accuracy of EBUSTBNA. Result: The sensitivity of EBUS-TBNAwas found to be 96.5 percent; whereas, specificity and positive predictive values were 100 percent. The negative predictive value was calculated at 50 percent. Diagnostic accuracy of the procedure was found to be 96.67 percent. Conclusion: EBUS-TBNA is a sensitive and a specific test and is accurate in diagnosing mediastinal and hilar pathologies. (author)

  4. Ultrasound-guided brachial plexus block: a study on 30 patients

    Directory of Open Access Journals (Sweden)

    Amiri HR

    2009-05-01

    Full Text Available "n Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Successful brachial plexus blocks rely on proper techniques of nerve localization, needle placement, and local anesthetic injection. Standard approaches used today (elicitation of paresthesia or nerve-stimulated muscle contraction, unfortunately, are all "blind" techniques resulting in procedure-related pain and complications. Ultrasound guidance for brachial plexus blocks can potentially improve success and complication rates. This study presents the ultrasound-guided brachial plexus blocks for the first time in Iran in adults and pediatrics. "n"n Methods: In this study ultrasound-guided brachial plexus blocks in 30 patients (25 adults & 5 pediatrics scheduled for an elective upper extremity surgery, are introduced. Ultrasound imaging was used to identify the brachial plexus before the block, guide the block needle to reach target nerves, and visualize the pattern of local anesthetic spread. Needle position was further confirmed by nerve stimulation before injection. Besides basic variables, block approach, block time, postoperative analgesia duration (VAS<3 was considered as target pain control opioid consumption during surgery, patient satisfaction and block related complications were reported

  5. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  6. The reliability of ultrasound-guided core needle biopsy in the evaluation of non-palpable solid breast lesions using 18-gauge needles

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sung Chul; Kim, Young Sook [Chosun University College of Medicine, Gwangju (Korea, Republic of); Sneige, Nour [The University of Texas M.D. Andreson Carcer Canter, Houston (United States)

    2003-04-01

    Ultrasound-guided core needle biopsy (US CNB) is increasingly used in the histologic evaluation of non-palpable solid breast lesions. We retrospectively investigated the diagnostic accuracy of this technique, using an 18-gauge needle in 422 non-palpable breast lesions. 583 female patients with an average age 56 (range, 22-90) years underwent 590 US CNBs. Between January 1994 and December 1999, using 18-gauge needles, an average of four cores per lesion was obtained. Three hundred and eighty-five lesions were subsequently surgically excised; for 14 of these, the pathologic diagnosis was breast carcinoma metastasis, while 23 with benign diagnoses were clinically followed up for {>=}2.5 years and were considered for analysis. Of the 422 lesions, 340 (80.6%) were malignant [308 invasive, 24 ductal carcinoma in situ (DCIS), 7 DCIS with undetermined invasion and 1 DCIS vs. lobular carcinoma in situ], 67 (15.9%) were benign [30 fibroadenoma (FA) and 37 other diagnoses], and five (1.2%) were fibroepithelial lesions. The remaining ten samples (2,4%) included six cases of atypical ductal hyperplasia (ADH), two of atypical hyperplasia (AH), and two of lobular neoplasia. The sensitivity, specificity, positive predictive value, and negative predictive value of CNBs were 99%, 100%, 100%, and 96%, respectively. Two cases of invasive carcinoma were missed at CNB; there was no false-positive diagnosis. Five of six ADHs and one of two AHs were found to be carcinomas (3 DCIS and 3 infiltrating duct carcinomas). Sixteen of 24 (66.7%) cases of DCIS were found at excision to be invasion carcinomas. Of 31 FAs, two (6.5%) were found to be low-grade phyllodes tumor (PT). The five fibroepithelial lesions were shown at excision to be either PT (n=4) or FA (n=1). US CNB using an 18-gauge needle is a safe and reliable means of diagnosing breast carcinoma. Because of the high prevalence of ductal carcinoma is these lesions; findings of ADH/AH at US CNB indicate that surgical excision is needed

  7. Fine Needle Aspiration Cytology In Tumour Diagnosis | Obaseki ...

    African Journals Online (AJOL)

    Fine needle aspiration cytology (FNAC), a technique for obtaining cellular material for cytological examination and diagnosis using a 21- gauge or smaller needle, is performed using a 5, 10, or 20ml syringe either freehand or using special syringe holders. It allows a minimally invasive, rapid diagnosis of tissue samples but

  8. Fine needle diagnosis in lumbar osteomyelitis

    International Nuclear Information System (INIS)

    Joshi, K.B.; Brinker, R.A.

    1983-01-01

    Lumbar vertebral body and disk infection, presenting as low back pain, is a relatively uncommon disease but is seen more often in drug addicts. Radiographs show typical changes of infection of the lumbar vertebrae and adjacent disc. Under local anesthesia a fine needle is placed, saline injected, and aspirated. The entire needle-syringe unit is submitted to the bacteriology department. Pseudomonas infection is usually found. This method of diagnosis is simple, cost effective, well accepted by the patients, and can be done on outpatients. (orig.)

  9. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display.

    Science.gov (United States)

    Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R

    2012-08-01

    A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.

  10. Computed tomography-guided percutaneous core needle biopsy of deep seated bone lesions in two dogs

    International Nuclear Information System (INIS)

    Mori, T.; Sakaida, M.; Yamada, M.; Akiyama, H.; Takai, Y.; Sakai, H.; Maruo, K.

    2006-01-01

    Computed Tomography (CT)-guided percutaneous core needle biopsies were undertaken for the diagnosis of osteosarcoma in the pelvis (case 1) and myeloma (case 2) in the seventh lumber vertebra which were difficult to targeted by palpation, ultrasound or fluoroscopy. In both cases, enough tissue for pathological diagnosis were obtained without any complication. CT-guided biopsy was thought to be a safe, easy and effective technique for the evaluation of the deep seated bone lesion

  11. Ultrasound assistance in differentiating malignant thyroid nodules from benign ones

    International Nuclear Information System (INIS)

    Zahir, S.T.; Sefidrokh, S.; Heidari, F.; Vakili, M.; Ghaneei, A.

    2017-01-01

    The search is ongoing for simple, effective ways to identify and differentiate thyroid nodules in order to avoid invasive procedures. This study aims to perform an ultrasound assessment of clinically suspected patients with malignant nodules, to perform a fine needle biopsy on them, and to compare the results obtained. Methods: In total, 135 patients with thyroid nodules suspected to be malignant in the ultrasound underwent ultrasound-guided fine needle biopsies. The patients' gender, age, ultrasound views (echogenicity, shape, and calcification type), nodule size, number of nodules, and needle biopsy results were retrospectively evaluated. Results: Of the 135 patients, 117 (86.7 percent) were female and 18 (13.3 percent) were male. In terms of age, 67 (49.16 percent) were younger than 40 and the rest were older. According to the Chi-square test, a significant relationship was found between the type of nodule and calcification found in the ultrasound views (p=0.001). The nodule type was not significantly related to gender (p=0.563) or to the number of nodules (p=0.128); however, there was a significant relationship between nodule size and type (p=0.001). Ultrasound specificity, sensitivity, positive and negative predictive values, and accuracy for differentiating benign from malignant nodules were 93.2 percent, 93.8 percent, 81.1 percent, 98 percent, and 93.3 percent, respectively. Conclusions: Ultrasound views (comet tail artefact and linear echogenic foci) were better predictors of benign nodules than of malignant ones, while round, echogenic foci, brighter and larger than typical micro-calcifications without any visible echoes and multiple punctuate round echogenic foci were better predicted malignancy. (author)

  12. Successful treatment of athletic pubalgia in a lacrosse player with ultrasound-guided needle tenotomy and platelet-rich plasma injection: a case report.

    Science.gov (United States)

    Scholten, Paul M; Massimi, Stephen; Dahmen, Nick; Diamond, Joanne; Wyss, James

    2015-01-01

    Athletic pubalgia is a syndrome of persistent groin pain due to chronic repetitive trauma or stress involving the pelvic joints and many musculotendinous structures that cross the anterior pelvis. As a result, the differential diagnosis can be complex, but insertional tendinopathies are the most common. This case report describes a novel approach to the treatment of distal rectus abdominis tendinopathies with ultrasound-guided needle tenotomy and platelet-rich plasma (PRP) injection. After injection, the patient returned to pain-free play at his previous level of intensity. This suggests that PRP may be a useful treatment for this diagnosis. Copyright © 2015. Published by Elsevier Inc.

  13. Diagnostic Benefit of Thyroglobulin Measurement in Fine-Needle Aspiration for Diagnosing Metastatic Cervical Lymph Nodes from Papillary Thyroid Cancer: Correlations with US Features

    International Nuclear Information System (INIS)

    Jeon, Se Jeong; Kim, Eun Hee; Son, Kyu Ri; Park, Do Joon; Cho, Bo Youn; Na, Dong Gyu; Park, Jeong Seon; Baek, Jung Hwan; Kim, Yoon Suk

    2009-01-01

    Our goals were to determine the added value of fine-needle aspiration biopsy (FNAB)-thyroglobulin (Tg) measurements over FNAB-cytology alone for diagnosing metastatic nodes, and to determine whether the ultrasound features of lymph nodes can be used to identify lymph nodes that may benefit from FNAB-Tg measurement in patients with papillary thyroid cancer. We retrospectively evaluated 76 surgically proven cervical lymph nodes. Twenty-nine patients were awaiting surgery and 18 patients had undergone thyroid surgery for papillary thyroid cancer. Ultrasound-guided FNAB and Tg measurements were performed and the ultrasound features were evaluated. The accuracies, sensitivities, and specificities of FNAB-cytology, FNAB-Tg, and combined FNAB-Tg/cytology were 90%, 80%, and 100%; 92%, 95%, and 90%; and 93%, 96%, and 90%, respectively. The diagnostic sensitivity of FNAB-Tg for metastatic nodes was significantly higher than that of FNAB-cytology (p = 0.011). Furthermore, combined FNAB-Tg/cytology significantly increased sensitivity (p = 0.002) and accuracy (p = 0.03) as compared with FNAB-cytology. Combined FNAB-Tg/cytology is significantly more sensitive and accurate at detecting metastatic nodes than FNAB-cytology alone. FNAB-Tg was better at diagnosing metastases in small lymph nodes

  14. A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology

    Directory of Open Access Journals (Sweden)

    Neda Rad

    2016-12-01

    Full Text Available Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation.

  15. A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology.

    Science.gov (United States)

    Rad, Neda; Heidarnezhad, Arash; Soheili, Setareh; Mohammad-Alizadeh, Amir Houshang; Nikmanesh, Arash

    2016-01-01

    Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation.

  16. Comparison of two ultrasound-guided injection techniques targeting the sacroiliac joint region in equine cadavers.

    Science.gov (United States)

    Stack, John David; Bergamino, Chiara; Sanders, Ruth; Fogarty, Ursula; Puggioni, Antonella; Kearney, Clodagh; David, Florent

    2016-09-20

    To compare the accuracy and distribution of injectate for cranial (CR) and caudomedial (CM) ultrasound-guided injections of equine sacroiliac joints. Both sacroiliac joints from 10 lumbosacropelvic specimens were injected using cranial parasagittal (CR; curved 18 gauge, 25 cm spinal needles) and caudomedial (CM; straight 18 gauge, 15 cm spinal needles) ultrasound-guided approaches. Injectate consisted of 4 ml iodinated contrast and 2 ml methylene blue. Computed tomographical (CT) scans were performed before and after injections. Time for needle guidance and repositioning attempts were recorded. The CT sequences were analysed for accuracy and distribution of contrast. Intra-articular contrast was detected in sacroiliac joints following 15/40 injections. The CR and CM approaches deposited injectate ≤2 cm from sacroiliac joint margins following 17/20 and 20/20 injections, respectively. Median distance of closest contrast to the sacroiliac joint was 0.4 cm (interquartile range [IQR]: 1.5 cm) for CR approaches and 0.6 cm (IQR: 0.95 cm) for CM approaches. Cranial injections resulted in injectate contacting lumbosacral intertransverse joints 15/20 times. Caudomedial injections were perivascular 16/20 times. Safety and efficacy could not be established. Cranial and CM ultrasound-guided injections targeting sacroiliac joints were very accurate for periarticular injection, but accuracy was poor for intra-articular injection. Injectate was frequently found in contact with interosseous sacroiliac ligaments, as well as neurovascular and synovial structures in close vicinity of sacroiliac joints.

  17. Diagnostic accuracy of lymphoma established by fine-needle aspiration cytological biopsy

    Science.gov (United States)

    Delyuzar; Amir, Z.; Suryadi, D.

    2018-03-01

    Based on Globocan data in 2012, it is estimated that about 14,495 Indonesians suffer from lymphoma, both Hodgkin’s lymphoma, and non-Hodgkin’s lymphoma. Some areas of specialization still doubt the accuracy of cytology diagnosis of fine needle aspiration biopsy.This study is a diagnostic test with a cross sectional analytic design to see how the cytology diagnostic accuracy of fine needle aspiration aspirate in lymphoma. It was in Department of Anatomical Pathology Faculty of Medicine USU, Haji Adam Malik Hospital, Dr.Pirngadi hospital, or private clinic in Medan. Peripheral cytology technique biopsy of fine needle aspiration on lymph node subsequently stained with Giemsa, when the cytology of lymphoma is obtained and confirmed by histopathologic examination. Cytology and histopathologic examination will be tested by Diagnostic Test and assessed for its sensitivity and specificity. The diagnostic of lymphoma cytology provides 93.33% sensitivity and 92.31% specificity when confirmed by histopathological examination. Positive predictive value and negative predictive value of 96.55% and 85.71% respectively. In conclusion, the cytology of fine needle aspiration biopsy is accurate enough to be used as a diagnostic tool, so it is advisable to establish a lymphoma diagnosis to perform a needle aspiration biopsy examination.

  18. Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures

    International Nuclear Information System (INIS)

    Sommer, C.M.; Huber, J.; Radeleff, B.A.; Hosch, W.; Stampfl, U.; Loenard, B.M.; Hallscheidt, P.; Haferkamp, A.; Kauczor, H.U.; Richter, G.M.

    2011-01-01

    Aim: To report our experience of combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures. Patients and methods: Eighteen patients (23 kidneys) with non-obstructive uropathy due to urine leaks underwent combined CT- and fluoroscopy-guided nephrostomy. All procedures were indicated as second-line interventions after failed ultrasound-guided nephrostomy. Thirteen males and five females with an age of 62.3 ± 8.7 (40–84) years were treated. Urine leaks developed in majority after open surgery, e.g. postoperative insufficiency of ureteroneocystostomy (5 kidneys). The main reasons for failed ultrasound-guided nephrostomy included anatomic obstacles in the puncture tract (7 kidneys), and inability to identify pelvic structures (7 kidneys). CT-guided guidewire placement into the collecting system was followed by fluoroscopy-guided nephrostomy tube positioning. Procedural success rate, major and minor complication rates, CT-views and needle passes, duration of the procedure and radiation dose were analyzed. Results: Procedural success was 91%. Major and minor complication rates were 9% (one septic shock and one perirenal abscess) and 9% (one perirenal haematoma and one urinoma), respectively. 30-day mortality rate was 6%. Number of CT-views and needle passes were 9.3 ± 6.1 and 3.6 ± 2.6, respectively. Duration of the complete procedure was 87 ± 32 min. Dose-length product and dose-area product were 1.8 ± 1.4 Gy cm and 3.9 ± 4.3 Gy cm 2 , respectively. Conclusions: Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures was feasible with high technical success and a tolerable complication rate.

  19. Improved laboratory resource utilization and patient care with the use of rapid on-site evaluation for endobronchial ultrasound fine-needle aspiration biopsy.

    Science.gov (United States)

    Collins, Brian T; Chen, Alexander C; Wang, Jeff F; Bernadt, Cory T; Sanati, Souzan

    2013-10-01

    Endobronchial ultrasound guided (EBUS) fine-needle aspiration (FNA) biopsy has become widely used to evaluate patients with thoracic abnormalities. Rapid on-site evaluation (ROSE) can provide the bronchoscopist with immediate evaluation findings during the procedure. This study examines EBUS FNA biopsy procedures with and without ROSE, and investigates the impact of ROSE service on the EBUS procedure and laboratory resource utilization. The cytopathology database at Washington University Medical Center, St. Louis, Missouri, was searched for EBUS FNA biopsy cases before and after introduction of ROSE service, and a matched cohort was collected. Reports were reviewed and pertinent data was collected, such as sites biopsied, ROSE performance, slide smears, cell blocks, and diagnostic categories. Statistical analysis of the results was performed. A matched case-controlled EBUS FNA cohort of 340 patients (680 total) for each category of non-ROSE and ROSE service were identified. There was a 33% reduction in the number of sites biopsied with ROSE. A total of 68% of patients with ROSE had just one biopsy site compared to only 36% of non-ROSE patients. There was a 30% decrease in total slides (mean, 5.27 slides) after the introduction of ROSE. All of these improvements were statistically significant. EBUS FNA biopsy ROSE service benefits patients by contributing to significantly fewer biopsies and improved utilization of health care resources. ROSE service results in substantially fewer total slides, which has a significant impact on the cytopathology laboratory work effort. The use of ROSE for EBUS FNA biopsy provides significant improvements in patient care and laboratory resource utilization. © 2013 American Cancer Society.

  20. Extrapulmonary tuberculosis: Fine needle aspiration cytology ...

    African Journals Online (AJOL)

    Patients and Methods: This is a consecutive 9-year analysis of patients with peripheral lymphadenopathy. All the patients had fine needle aspiration. Smears were made, fixed in 95% alcohol and stained with hematoxylin and eosin and Zeihl Neelsen stains. Results: 48 patients, 31 males and 17 females, were analyzed.

  1. Contrast-Enhanced Ultrasound Improves the Pathological Outcomes of US-Guided Core Needle Biopsy That Targets the Viable Area of Anterior Mediastinal Masses

    Directory of Open Access Journals (Sweden)

    Jian-hua Zhou

    2018-01-01

    Full Text Available Based on the option that ultrasound-guided core needle biopsy (US-CNB of the enhanced portion of anterior mediastinal masses (AMMs identified by contrast-enhanced ultrasound (CEUS would harvest viable tissue and benefit the histological diagnoses, a retrospective study was performed to elucidate the correlation between the prebiopsy CEUS and diagnostic yield of AMMs and found that CEUS potentially improved the diagnostic yield of AMMs compared with conventional US with a significant increase in the cellularity of samples. Furthermore, the marginal blood flow signals and absence of necrosis can predict the diagnostic yield of AMM. It was concluded that US-CNB of the viable part of AMMs, as verified by CEUS, was able to harvest sufficient tissue with more cellularity that could be used for ancillary studies and improve the diagnostic yield. And CEUS was recommended to those patients with AMMs undergoing repeated US-CNB, with the absence of marginal blood signals or presence of necrosis.

  2. Diagnosis Of Thyroid Enlargement: Use Of Fine Needle Aspiration ...

    African Journals Online (AJOL)

    One hundred and ten Fine Needle Aspiration Biopsies (FNAC) obtained from 87 patients with thyroid enlargement or nodules were retrospectively reviewed. Aspiration biopsy was accomplished using 21-gauge needle attached with 20-ml plastic syringe. There were 14 males and 73 females involved in the study. Sixty- four ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Because ultrasound provides real-time images, it also can be used to guide procedures such as needle ...

  4. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  5. Steroid injection for painful shoulder: Usefulness of ultrasound-guided approach

    International Nuclear Information System (INIS)

    Lee, Min Hee

    2004-01-01

    To evaluate the efficacy of steroid injection into the subacromial bursa and biceps tendon sheath for painful shoulders and the usefulness of ultrasound-guided approach. Seventeen shoulders of twelve patients with shoulder pain and limited motion were included, and these patient were clinically diagnosed as a painful arc syndrome. Under ultrasound guidance, steroid injection was performed into the subacormial bursa (13 cases) and biceps tendon sheath (4 cases). In 7 cases, 1 mL of steroid was used while the remaining six patients received a mixture of 1 mL of steroid and 1 ml of lidocaine. Both shoulders of two patients received 0.5 mL of steroid. The location of needle and injection duration of fluid were continuously monitored, and complications such as leakage of steroid were recorded. Medical records were reviewed for the presence of pain relief and increasing range of motion following the injection. On ultrasonogram, the needle within the subacromial bursa and biceps tendon sheath was seen as a linear echogenic structure, and injected fluid was identified. There was neither the leakage of steroid injection nor any other complications. In 16 (94%) of 17 shoulders, there was decreased intensity of shoulder pain while increased range of motion was noted in three patients following the injection. Steroid injection into the subacormial bursa and biceps tendon sheath is effective in treating shoulder pain and limited range of motion of the shoulder, and ultrasound is useful guiding method.

  6. MRI-guided trephine biopsy and fine-needle aspiration in the diagnosis of bone lesions in low-field (0.23 T) MRI system using optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Klemola, Rauli; Ojala, Risto; Jyrkinen, Lasse; Tervonen, Osmo; Lappi-Blanco, Elisa; Soini, Ylermi

    2002-01-01

    The purpose of this study was to evaluate the feasibility of MRI-guided bone biopsy with optical instrument tracking and evaluate advantage of combined fine-needle aspiration (FNA) with trephine biopsy. Twenty trephine bone biopsies and 13 FNAs were performed under MRI and CT guidance in 14 patients. Informed consent was obtained from all patients. The evaluation of diagnostic accuracy was achieved by comparing the histopathological and cytological diagnosis with current or final diagnosis made during 6-month clinical follow-up. A 0.23-T open MRI scanner with interventional tools (Outlook Proview, Marconi Medical Systems, Cleveland, Ohio) was used. A surface coil was used. For trephine biopsy MRI-compatible bone biopsy set (Daum medical, Schwerin, Germany) was used. The FNA was performed with MRI compatible 20-G needle (Cook, Bloomington, Ind.). The diagnostic accuracy of MRI-guided trephine biopsy was 95%. The FNA sample diagnosis concurred with the histological in 54%. Our results show that MRI guidance in bone biopsies is accurate and safe. It is comparable to CT-guided or open biopsy. The role of combined FNA with bone biopsies remains controversial. (orig.)

  7. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    International Nuclear Information System (INIS)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat; Del Rey Fernandez, David; Downey, Donal; Fenster, Aaron

    2008-01-01

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75±0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists

  8. A compact mechatronic system for 3D ultrasound guided prostate interventions

    International Nuclear Information System (INIS)

    Bax, Jeffrey; Smith, David; Bartha, Laura; Montreuil, Jacques; Sherebrin, Shi; Gardi, Lori; Edirisinghe, Chandima; Fenster, Aaron

    2011-01-01

    Purpose: Ultrasound imaging has improved the treatment of prostate cancer by producing increasingly higher quality images and influencing sophisticated targeting procedures for the insertion of radioactive seeds during brachytherapy. However, it is critical that the needles be placed accurately within the prostate to deliver the therapy to the planned location and avoid complications of damaging surrounding tissues. Methods: The authors have developed a compact mechatronic system, as well as an effective method for guiding and controlling the insertion of transperineal needles into the prostate. This system has been designed to allow guidance of a needle obliquely in 3D space into the prostate, thereby reducing pubic arch interference. The choice of needle trajectory and location in the prostate can be adjusted manually or with computer control. Results: To validate the system, a series of experiments were performed on phantoms. The 3D scan of the string phantom produced minimal geometric error, which was less than 0.4 mm. Needle guidance accuracy tests in agar prostate phantoms showed that the mean error of bead placement was less then 1.6 mm along parallel needle paths that were within 1.2 mm of the intended target and 1 deg. from the preplanned trajectory. At oblique angles of up to 15 deg. relative to the probe axis, beads were placed to within 3.0 mm along a trajectory that were within 2.0 mm of the target with an angular error less than 2 deg. Conclusions: By combining 3D TRUS imaging system to a needle tracking linkage, this system should improve the physician's ability to target and accurately guide a needle to selected targets without the need for the computer to directly manipulate and insert the needle. This would be beneficial as the physician has complete control of the system and can safely maneuver the needle guide around obstacles such as previously placed needles.

  9. Sci-Thur AM: YIS – 03: Combining sagittally-reconstructed 3D and live-2D ultrasound for high-dose-rate prostate brachytherapy needle segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Hrinivich, Thomas; Hoover, Douglas; Surry, Kathleen; Edirisinghe, Chandima; D’Souza, David; Fenster, Aaron; Wong, Eugene [University of Western Ontario, London Regional Cancer Program/LHSC, London Regional Cancer Program/LHSC, Robarts Research Institute, London Regional Cancer Program/LHSC, Robarts Research Institute, University of Western Ontario (Canada)

    2016-08-15

    Ultrasound-guided high-dose-rate prostate brachytherapy (HDR-BT) needle segmentation is performed clinically using live-2D sagittal images. Organ segmentation is then performed using axial images, introducing a source of geometric uncertainty. Sagittally-reconstructed 3D (SR3D) ultrasound enables both needle and organ segmentation, but suffers from shadow artifacts. We present a needle segmentation technique augmenting SR3D with live-2D sagittal images using mechanical probe tracking to mitigate image artifacts and compare it to the clinical standard. Seven prostate cancer patients underwent TRUS-guided HDR-BT during which the clinical and proposed segmentation techniques were completed in parallel using dual ultrasound video outputs. Calibrated needle end-length measurements were used to calculate insertion depth errors (IDEs), and the dosimetric impact of IDEs was evaluated by perturbing clinical treatment plan source positions. The proposed technique provided smaller IDEs than the clinical approach, with mean±SD of −0.3±2.2 mm and −0.5±3.7mm respectively. The proposed and clinical techniques resulted in 84% and 43% of needles with IDEs within ±3mm, and IDE ranges across all needles of [−7.7mm, 5.9mm] and [−9.3mm, 7.7mm] respectively. The proposed and clinical IDEs lead to mean±SD changes in the volume of the prostate receiving the prescription dose of −0.6±0.9% and −2.0±5.3% respectively. The proposed technique provides improved HDR-BT needle segmentation accuracy over the clinical technique leading to decreased dosimetric uncertainty by eliminating the axial-to-sagittal registration, and mitigates the effect of shadow artifacts by incorporating mechanically registered live-2D sagittal images.

  10. Ultrasound-guided procedures around the wrist and hand: How to do

    International Nuclear Information System (INIS)

    Orlandi, Davide; Corazza, Angelo; Silvestri, Enzo; Serafini, Giovanni; Savarino, Edoardo Vincenzo; Garlaschi, Giacomo; Mauri, Giovanni; Cimmino, Marco Amedeo; Sconfienza, Luca Maria

    2014-01-01

    Ultrasound has emerged as a low-cost, radiation-free and effective imaging technique to detect joint abnormalities and to guide percutaneous procedures. Being superficial, wrist and hand tendons and joints represent a good target to perform such procedures using ultrasound guidance. This kind of approach allows for a clear and real-time visualization of the needles during their whole path. In this setting, the knowledge of technical aspects and tips is essential to act in the most accurate way on target tissues that can be as small as a few millimetres. The aim of this review is to summarize the local treatments of inflammatory and degenerative disease described in literature (such as treatment of De Quervain's tenosynovitis, trigger finger, trapezio-metacarpal joint osteoarthritis, etc.), emphasizing precautions and tricks based on day-by-day experience that may help to improve the outcome of percutaneous ultrasound-guided procedures around the wrist and hand

  11. Ultrasound-guided procedures around the wrist and hand: How to do

    Energy Technology Data Exchange (ETDEWEB)

    Orlandi, Davide; Corazza, Angelo [Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Genova, Via L.B. Alberti 4, 16132 Genova (Italy); Silvestri, Enzo [Diagnostica per Immagini, Ospedale Evangelico Internazionale, Corso Solferino 29A, 16100 Genova (Italy); Serafini, Giovanni [Dipartimento di Diagnostica per Immagini, Ospedale Santa Corona, Via XXV Aprile 38, 17037 Pietra Ligure, Savona (Italy); Savarino, Edoardo Vincenzo [Dipartimento di Scienze Chirurgiche, Oncologiche e Gastroenterologiche, Università degli Studi di Padova, Via Giustiniani, Padova (Italy); Garlaschi, Giacomo [Dipartimento di Scienze per la Salute, Università degli Studi di Genova, Via L.B. Alberti 4, 16132 Genova (Italy); Mauri, Giovanni [Servizio di Radiologia, IRCCS Policlinico San Donato, Piazza Malan 2, San Donato Milanese, Milano (Italy); Cimmino, Marco Amedeo [Dipartimento di Medicina Interna, Università degli Studi di Genova, Via L.B. Alberti 4, 16132 Genova (Italy); Sconfienza, Luca Maria, E-mail: io@lucasconfienza.it [Servizio di Radiologia, IRCCS Policlinico San Donato, Piazza Malan 2, San Donato Milanese, Milano (Italy); Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Piazza Malan 2, San Donato Milanese, Milano (Italy)

    2014-07-15

    Ultrasound has emerged as a low-cost, radiation-free and effective imaging technique to detect joint abnormalities and to guide percutaneous procedures. Being superficial, wrist and hand tendons and joints represent a good target to perform such procedures using ultrasound guidance. This kind of approach allows for a clear and real-time visualization of the needles during their whole path. In this setting, the knowledge of technical aspects and tips is essential to act in the most accurate way on target tissues that can be as small as a few millimetres. The aim of this review is to summarize the local treatments of inflammatory and degenerative disease described in literature (such as treatment of De Quervain's tenosynovitis, trigger finger, trapezio-metacarpal joint osteoarthritis, etc.), emphasizing precautions and tricks based on day-by-day experience that may help to improve the outcome of percutaneous ultrasound-guided procedures around the wrist and hand.

  12. A New Ultrasound-Guided Puncture Device with Augmented Degrees of Performance Freedom and Ability to Attach to Most Convex Probes

    International Nuclear Information System (INIS)

    Jung, Sung Il; Son, Kyu Ri; Kim, Young Jun; Jeon, Hae Jeong; Park, Sang Woo; Cho, Jeong Yeon; Kim, Seung Hyup

    2008-01-01

    To evaluate the performance of a newly-designed ultrasound (US)-guided puncture device. A newly-designed US-guided puncture device was composed of a guide segment and an attachable segment. The guide segment allowed the needle to be placed in the plane of US view with a maximal degree of freedom, and the attachable segment was designed to attach to most convex US probes. Six operators punctured 144 targets in phantoms using either the new device (n = 72) or free-hand technique (n = 72). The number of required needle passages and the necessary procedure times were compared between the two groups. The number of required needle passages and the necessary procedure time were significantly reduced in five operators when the newly-designed US-guided puncture device was used (p < 0.05). A newly-designed US-guided puncture device, which allows for a maximal degree of freedom in needle placement and can attach to most convex US probes, showed good performance in our study

  13. Three-dimensional ultrasound image-guided robotic system for accurate microwave coagulation of malignant liver tumours.

    Science.gov (United States)

    Xu, Jing; Jia, Zhen-zhong; Song, Zhang-jun; Yang, Xiang-dong; Chen, Ken; Liang, Ping

    2010-09-01

    The further application of conventional ultrasound (US) image-guided microwave (MW) ablation of liver cancer is often limited by two-dimensional (2D) imaging, inaccurate needle placement and the resulting skill requirement. The three-dimensional (3D) image-guided robotic-assisted system provides an appealing alternative option, enabling the physician to perform consistent, accurate therapy with improved treatment effectiveness. Our robotic system is constructed by integrating an imaging module, a needle-driven robot, a MW thermal field simulation module, and surgical navigation software in a practical and user-friendly manner. The robot executes precise needle placement based on the 3D model reconstructed from freehand-tracked 2D B-scans. A qualitative slice guidance method for fine registration is introduced to reduce the placement error caused by target motion. By incorporating the 3D MW specific absorption rate (SAR) model into the heat transfer equation, the MW thermal field simulation module determines the MW power level and the coagulation time for improved ablation therapy. Two types of wrists are developed for the robot: a 'remote centre of motion' (RCM) wrist and a non-RCM wrist, which is preferred in real applications. The needle placement accuracies were robot with the RCM wrist was improved to 1.6 +/- 1.0 mm when real-time 2D US feedback was used in the artificial-tissue phantom experiment. By using the slice guidance method, the robot with the non-RCM wrist achieved accuracy of 1.8 +/- 0.9 mm in the ex vivo experiment; even target motion was introduced. In the thermal field experiment, a 5.6% relative mean error was observed between the experimental coagulated neurosis volume and the simulation result. The proposed robotic system holds promise to enhance the clinical performance of percutaneous MW ablation of malignant liver tumours. Copyright 2010 John Wiley & Sons, Ltd.

  14. Endobronchial Ultrasound-guided Transbronchial Needle Aspiration 
in the Diagnosis of Intrathoracic Metastasis from Extrapulmonary Malignancy

    Directory of Open Access Journals (Sweden)

    Jiayuan SUN

    2015-05-01

    Full Text Available Background and objective Endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA has been widely applied in diagnosing mediastinal and hilar adenopathy. This study is further to evaluate value and safety of EBUS-TBNA in diagnosing intrathoracic metastasis from extrapulmonary malignancy. Methods Prospectively analysis of 41 patients suspected intrathoracic metastasis from previous diagnosed/concurrent extrapulmonary malignancies in Shanghai Chest Hospital, with radiologic findings showing mediastinal/hilar lymph node enlargement or intrapulmonary lesion requiring EBUS-TBNA examination for pathological diagnosis. Results 41 candidate patients enrolled, and 67 mediastinal/hilar lymph nodes and 5 intrapulmonary lesions were aspirated. 14 intrathoracic metastasis, 10 primary lung cancer, 9 reactive lymphadenitis, 4 sarcoid-like reactions, and 1 tuberculosis was diagnosed by EBUS-TBNA. Sensitivity and accuracy of EBUS-TBNA in diagnosing intrathoracic metastasis was 87.50% and 95.12%, respectively. Immunohistochemistry (IHC was performed in 18 malignant tumors to obtain definite type or origin, twelve intrathoracic metastasis and 6 primary lung cancer were further confirmed. Conclusion EBUS-TBNA is a safe, effective method for the diagnosis of intrathoracic metastasis from extrapulmonary malignancy. IHC can provide additional evidence for distinguishing extrapulmonary malignancy from primary lung cancer.

  15. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  16. Ultrasound/Magnetic Resonance Image Fusion Guided Lumbosacral Plexus Block – A Clinical Study

    DEFF Research Database (Denmark)

    Strid, JM; Pedersen, Erik Morre; Søballe, Kjeld

    2014-01-01

    in a double-blinded randomized controlled trial with crossover design. MR datasets will be acquired and uploaded in an advanced US system (Epiq7, Phillips, Amsterdam, Netherlands). All volunteers will receive SSPS blocks with lidocaine added gadolinium contrast guided by US/MR image fusion and by US one week......Background and aims Ultrasound (US) guided lumbosacral plexus block (Supra Sacral Parallel Shift [SSPS]) offers an alternative to general anaesthesia and perioperative analgesia for hip surgery.1 The complex anatomy of the lumbosacral region hampers the accuracy of the block, but it may be improved...... by guidance of US and magnetic resonance (MR) image fusion and real-time 3D electronic needle tip tracking.2 We aim to estimate the effect and the distribution of lidocaine after SSPS guided by US/MR image fusion compared to SSPS guided by ultrasound. Methods Twenty-four healthy volunteers will be included...

  17. Gelatin model for training ultrasound-guided puncture

    Directory of Open Access Journals (Sweden)

    Alexandre Campos Moraes Amato

    2015-09-01

    Full Text Available BACKGROUND: It is indispensable that members of the medical profession receive the technical training needed to enable them to rapidly obtain effective vascular access. Training procedures should be used judiciously to familiarize students with the technique. However, existing models are expensive or ineffective, and models need to be developed that are similar to what will be encountered in real patients.OBJECTIVES: To demonstrate creation and application of a gelatin model for training ultrasound-guided puncture.METHOS: The model was made using a mixture of colorless gelatin and water in a transparent plastic receptacle with two pairs of orifices of different diameters, through which two plastic tubes were inserted, to simulate blood vessels.RESULTS: The model was a close approximation to the real medical procedure in several aspects, since gelatin has a similar consistency to human tissues, providing a more faithful reproduction of the tactile sensation at the moment when the needle reaches the interior of a vessel and its contents are aspirated.CONCLUSIONS: The method proposed here can be used to easily construct a low-cost model using everyday materials that is suitable for large-scale training of ultrasound-guided puncture.

  18. Technical aspects of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline - March 2017.

    Science.gov (United States)

    Polkowski, Marcin; Jenssen, Christian; Kaye, Philip; Carrara, Silvia; Deprez, Pierre; Gines, Angels; Fernández-Esparrach, Gloria; Eisendrath, Pierre; Aithal, Guruprasad P; Arcidiacono, Paolo; Barthet, Marc; Bastos, Pedro; Fornelli, Adele; Napoleon, Bertrand; Iglesias-Garcia, Julio; Seicean, Andrada; Larghi, Alberto; Hassan, Cesare; van Hooft, Jeanin E; Dumonceau, Jean-Marc

    2017-10-01

    For routine EUS-guided sampling of solid masses and lymph nodes (LNs) ESGE recommends 25G or 22G needles (high quality evidence, strong recommendation); fine needle aspiration (FNA) and fine needle biopsy (FNB) needles are equally recommended (high quality evidence, strong recommendation).When the primary aim of sampling is to obtain a core tissue specimen, ESGE suggests using 19G FNA or FNB needles or 22G FNB needles (low quality evidence, weak recommendation).ESGE recommends using 10-mL syringe suction for EUS-guided sampling of solid masses and LNs with 25G or 22G FNA needles (high quality evidence, strong recommendation) and other types of needles (low quality evidence, weak recommendation). ESGE suggests neutralizing residual negative pressure in the needle before withdrawing the needle from the target lesion (moderate quality evidence, weak recommendation).ESGE does not recommend for or against using the needle stylet for EUS-guided sampling of solid masses and LNs with FNA needles (high quality evidence, strong recommendation) and suggests using the needle stylet for EUS-guided sampling with FNB needles (low quality evidence, weak recommendation).ESGE suggests fanning the needle throughout the lesion when sampling solid masses and LNs (moderate quality evidence, weak recommendation).ESGE equally recommends EUS-guided sampling with or without on-site cytologic evaluation (moderate quality evidence, strong recommendation). When on-site cytologic evaluation is unavailable, ESGE suggests performance of three to four needle passes with an FNA needle or two to three passes with an FNB needle (low quality evidence, weak recommendation).For diagnostic sampling of pancreatic cystic lesions without a solid component, ESGE suggests emptying the cyst with a single pass of a 22G or 19G needle (low quality evidence, weak recommendation). For pancreatic cystic lesions with a solid component, ESGE suggests sampling of the solid component using the same technique as in the

  19. Ultrasound guided double injection of blood into cisterna magna: a rabbit model for treatment of cerebral vasospasm.

    Science.gov (United States)

    Chen, Yongchao; Zhu, Youzhi; Zhang, Yu; Zhang, Zixuan; Lian, Juan; Luo, Fucheng; Deng, Xuefei; Wong, Kelvin K L

    2016-02-06

    Double injection of blood into cisterna magna using a rabbit model results in cerebral vasospasm. An unacceptably high mortality rate tends to limit the application of model. Ultrasound guided puncture can provide real-time imaging guidance for operation. The aim of this paper is to establish a safe and effective rabbit model of cerebral vasospasm after subarachnoid hemorrhage with the assistance of ultrasound medical imaging. A total of 160 New Zealand white rabbits were randomly divided into four groups of 40 each: (1) manual control group, (2) manual model group, (3) ultrasound guided control group, and (4) ultrasound guided model group. The subarachnoid hemorrhage was intentionally caused by double injection of blood into their cisterna magna. Then, basilar artery diameters were measured using magnetic resonance angiography before modeling and 5 days after modeling. The depth of needle entering into cisterna magna was determined during the process of ultrasound guided puncture. The mortality rates in manual control group and model group were 15 and 23 %, respectively. No rabbits were sacrificed in those two ultrasound guided groups. We found that the mortality rate in ultrasound guided groups decreased significantly compared to manual groups. Compared with diameters before modeling, the basilar artery diameters after modeling were significantly lower in manual and ultrasound guided model groups. The vasospasm aggravated and the proportion of severe vasospasms was greater in ultrasound guided model group than that of manual group. In manual model group, no vasospasm was found in 8 % of rabbits. The ultrasound guided double injection of blood into cisterna magna is a safe and effective rabbit model for treatment of cerebral vasospasm.

  20. Extramedullary plasmacytoma. Fine needle aspiration findings.

    Science.gov (United States)

    Kumar, P V; Owji, S M; Talei, A R; Malekhusseini, S A

    1997-01-01

    To determine the role of fine needle aspiration cytology in the diagnosis of extramedullary plasmacytoma. The study group consisted of 13 patients with palpable masses at various sites. The tumors were aspirated for cytologic study. The smears revealed groups of mature and immature plasma cells at various stages of maturation. Mature plasma cells showed an eccentric nucleus and abundant, deep, basophilic cytoplasm with a paranuclear halo. Plasmablasts (immature plasma cells) showed a prominent, eccentric nucleus with single, large nucleolus and abundant, deep, basophilic cytoplasm with no paranuclear halo. Binucleate and multinucleate forms were also seen quite often. The tumors were excised, and the histologic sections confirmed the cytologic diagnosis. All the patients received radiotherapy. One patient (18 years old) developed recurrence and died due to extensive infiltration into the maxilla and mandible. Two patients (57 and 62 years) developed multiple myeloma one to two years after the excision of tumors, and both died two to three months later. The remaining 10 patients were alive and well at this writing. The smears from all 13 patients were diagnosed as extramedullary plasmacytomas by fine needle aspiration cytology.

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide procedures such as needle biopsies , in which a needle is used to sample cells (tissue) from an abnormal area in the ...

  2. Ultrasound of neck lymph nodes: How to do it and how do they look?

    Energy Technology Data Exchange (ETDEWEB)

    Ying, Michael [Department of Optometry and Radiography, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China); Ahuja, Anil T. [Department of Diagnostic Radiology and Organ Imaging, Chinese University of Hong Kong, Prince of Wales Hospital, Shatin New Territories, Hong Kong (China)]. E-mail: aniltahuja@cuhk.edu.hk

    2006-05-15

    Cervical lymphadenopathy is commonly caused by metastases, lymphoma, tuberculosis and reactive hyperplasia. Before making an accurate diagnosis of pathologic lymph nodes, a clear understanding of the normal appearances of cervical nodes is crucial. Ultrasound examination of cervical lymph nodes is common in routine clinical practice because of its high sensitivity and specificity when combined with ultrasound-guided fine-needle aspiration cytology (FNAC). This article reviews the ultrasound of cervical lymph nodes including classification of the nodes, equipment, scanning technique and sonographic appearances of normal and common abnormal lymph nodes. The sonographic appearance of unusual cervical lymphadenopathy and the value of three-dimensional ultrasound in the volumetric measurements of cervical nodes are also discussed.

  3. Ultrasound of neck lymph nodes: How to do it and how do they look?

    International Nuclear Information System (INIS)

    Ying, Michael; Ahuja, Anil T.

    2006-01-01

    Cervical lymphadenopathy is commonly caused by metastases, lymphoma, tuberculosis and reactive hyperplasia. Before making an accurate diagnosis of pathologic lymph nodes, a clear understanding of the normal appearances of cervical nodes is crucial. Ultrasound examination of cervical lymph nodes is common in routine clinical practice because of its high sensitivity and specificity when combined with ultrasound-guided fine-needle aspiration cytology (FNAC). This article reviews the ultrasound of cervical lymph nodes including classification of the nodes, equipment, scanning technique and sonographic appearances of normal and common abnormal lymph nodes. The sonographic appearance of unusual cervical lymphadenopathy and the value of three-dimensional ultrasound in the volumetric measurements of cervical nodes are also discussed

  4. A foreign body reaction to Surgicel® in a lymph node diagnosed by endobronchial ultrasound-guided transbronchial needle aspiration

    Directory of Open Access Journals (Sweden)

    Diana Badenes

    2017-01-01

    Full Text Available Surgicel ® (Ethicon, North Ryde, NSW, Australia is an absorbable sheet of oxidized cellulose polyanhydroglucuronic acid polymer used as an hemostatic in cardiovascular and thoracic surgery. In some cases, the retained material may cause foreign body granulomatous reactions and simulate tumor recurrence, an abscess, an hematoma, or an infection. We report the case of a 55-year-old patient who was operated of a lung adenocarcinoma. In the thoracic computed tomography scan 1 year after the surgery, a right paratracheal lymph node was detected, so endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA was performed suspecting recurrence of the tumor. The cytology results of the lymph node showed a nonnecrotizing granulomatous reaction secondary to Surgicel ® , used as an hemostatic during the surgery. The objective of presenting this case is to consider foreign body reaction to Surgicel ® in the differential diagnosis of postoperative suspicion of neoplastic recurrence, and on the other hand, to note that EBUS-TBNA enables diagnosis.

  5. Surgical treatment for mediastinal abscess induced by endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    Science.gov (United States)

    Yokoyama, Yujiro; Nakagomi, Takahiro; Shikata, Daichi; Higuchi, Rumi; Oyama, Toshio; Goto, Taichiro

    2017-07-14

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a useful and less invasive procedure for the definitive diagnosis of mediastinal and hilar lymph nodes. However, infectious complications can occur after EBUS-TBNA, although they are extremely rare. A 66-year-old man with necrotic and swollen lower paratracheal lymph nodes underwent EBUS-TBNA. A mediastinal abscess developed 9 days post-procedure. Surgical drainage and debridement of the abscess were performed along with lymph node biopsy followed by daily washing of the thoracic cavity. Surgical treatment was effective, leading to remission of the abscess. Biopsy revealed that the tumor was squamous cell carcinoma with no radiologically detected cancer elsewhere in the body. Mediastinal lung cancer was thus confirmed. Subsequent chemoradiotherapy led to the remission of the tumor. Mediastinitis after EBUS-TBNA is rare but should be considered, particularly if the target lymph nodes are necrotic. Mediastinitis can lead to serious and rapid deterioration of the patient's condition, for which surgical intervention is the treatment of choice.

  6. Design and application of model for training ultrasound-guided vascular cannulation in pediatric patients.

    Science.gov (United States)

    Pérez-Quevedo, O; López-Álvarez, J M; Limiñana-Cañal, J M; Loro-Ferrer, J F

    2016-01-01

    Central vascular cannulation is not a risk-free procedure, especially in pediatric patients. Newborn and infants are small and low-weighted, their vascular structures have high mobility because of tissue laxity and their vessels are superficial and with small diameter. These characteristics, together with the natural anatomical variability and poor collaboration of small children, make this technique more difficult to apply. Therefore, ultrasound imaging is increasingly being used to locate vessels and guide vascular access in this population. (a) To present a model that simulates the vascular system for training ultrasound-guided vascular access in pediatrics patients; (b) to ultrasound-guided vascular cannulation in the model. The model consisted of two components: (a) muscular component: avian muscle, (b) vascular component: elastic tube-like structure filled with fluid. 864 ecoguided punctures was realized in the model at different vessel depth and gauge measures were simulated, for two medical operators with different degree of experience. The average depth and diameter of vessel cannulated were 1.16 (0.42)cm and 0.43 (0.1)cm, respectively. The average number of attempts was of 1.22 (0.62). The percentage of visualization of the needle was 74%. The most frequent maneuver used for the correct location, was the modification of the angle of the needle and the relocation of the guidewire in 24% of the cases. The average time for the correct cannulations was 41 (35.8)s. The more frequent complications were the vascular perforation (11.9%) and the correct vascular puncture without possibility of introducing the guidewire (1.2%). The rate of success was 96%. The model simulates the anatomy (vascular and muscular structures) of a pediatric patient. It is cheap models, easily reproducible and a useful tool for training in ultrasound-guided puncture and cannulation. Copyright © 2015 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... biopsies , in which needles are used to sample cells from an abnormal area for laboratory testing. image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ...

  8. CT-guided puncture

    International Nuclear Information System (INIS)

    Noeldge, G.; Richter, G.M.; Grenacher, L.; Brado, M.; Kauffmann, G.W.

    1996-01-01

    Sonographic and CT-guided punctures allow the evaluation of suspected lesions in the head, thorax, abdomen, retroperitoneum and skeletal system. The size of the lesion to be evaluated determines the size and the diameter of the puncture needle. The quantity of the material obtained will be defined by the diameter of the needle, i.e. fine-needle biopsy is more adequate for cytological than for histological evaluation. Strict adherence to the indications and contraindications for puncture and painstaking performance of the procedure go a long why towards minimizing the complications. The advantage of CT-guided puncture, in contrast to an ultrasound-guided procedure, is visualization during the puncture procedure free from overshadowing. This permits punctures of lesions located deep in the thorax or the abdomen which are overshadowed by the lungs, by air in the small or large bowel or by bone structures. Moreover, this technique yields much more information about the tissues and organs surrounding the suspected lesion. This information is much more investigator-related with ultrasoundguided puncture. Therefore, the CT-guided puncture has become mandatory in the evaluation of suspected lesions. Moreover, using the same technique, percutaneous drainage of fluids in the interpleural space, abscesses in organs, hematomas, lymphoceles and urinomas; ablation of metastases; and sympathicolysis can be carried out. CT-guided puncture thus changes from a minimally invasive diagnostic procedure to a minimally invasive therapy. (orig./MG) [de

  9. Endoscopic ultrasound-guided radiofrequency ablation of the pancreas

    DEFF Research Database (Denmark)

    Silviu, Ungureanu Bogdan; Daniel, Pirici; Claudiu, Mărgăritescu

    2015-01-01

    ultrasound (EUS)-guided radiofrequency ablation (RFA) probe through a 19G needle in order to achieve a desirable necrosis area in the pancreas. Radiofrequency ablation of the head of the pancreas was performed on 10 Yorkshire pigs with a weight between 25 kg and 35 kg and a length of 40-70 cm. Using an EUS...... analysis revealed increased values of amylase, alkaline phosphatase, and gamma-glutamyl transpeptidase on the 3rd day but a decrease on the 5th day. After necropsy and isolation of the pancreas, the ablated area was easily found, describing a solid necrosis. The pathological examination revealed...

  10. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer

    NARCIS (Netherlands)

    Konge, L.; Vilmann, P.; Clementsen, P.; Annema, J. T.; Ringsted, C.

    2012-01-01

    Background and study aims: Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was

  11. Guided interventions in musculoskeletal ultrasound: what's the evidence?

    International Nuclear Information System (INIS)

    Davidson, J.; Jayaraman, S.

    2011-01-01

    Increasing histological and radiological understanding of the processes involved in soft-tissue injury is leading to novel targeted treatments. A number of reviews have recommended that these treatments should be performed with image guidance. This review describes current ultrasound-guided interventions and injections, together with the level of evidence for these. Discussion of guided interventions will include; percutaneous lavage (barbotage), brisement, dry needling, electrocoagulation, and of guided injections; corticosteroids, autologous substances (blood and platelet rich plasma), sclerosants, and prolotherapy (hyperosmolar dextrose). Representative imaging illustrating some of these techniques is included for correlation with the methods described. As these procedures are often performed in sportspeople, it is essential that the radiologist is aware of prohibited substances and methods outlined in an annual publication from the World Anti-Doping Association (WADA). Finally, future directions, including the use of autologous substances, mesenchymal and stem cells will be discussed.

  12. Computed tomography-guided needle biopsy of lung lesions in fourteen cats and dogs

    International Nuclear Information System (INIS)

    Yoshida, K.; Mori, T.; Yamada, M.; Sakaida, M.; Yonemaru, K.; Murakami, M.; Sakai, H.; Maruo, K.

    2007-01-01

    Computed tomography (CT)-guided fine-needle aspirates (FNA) or core biopsies of lung lesions were performed in nine dogs and five cats. A clinical diagnosis was obtained in twelve of fourteen animals (85%), namely 80% FNA and 100% core biopsies. Eight animals had other mass (es) apart from the lung, and five were diagnosed to metastases. In only one case, the lung mass was histopathologically diagnosed as a malignant primary tumor. Iatrogenic complications through the lung biopsies were noted in four animals, and three showed mild pneumothorax on CT images and one was bleeding from the needle. However, between fifteen and thirty minutes after the biopsy, no animal indicated signs of pneumothorax or hemorrhage

  13. Ultrasound-guided injection of triamcinolone and bupivacaine in the management of De Quervain's disease.

    Science.gov (United States)

    Jeyapalan, Kanagaratnam; Choudhary, Surabhi

    2009-11-01

    The aim of this study was to describe the technique and usefulness of ultrasound-guided intrasynovial injection of triamcinolone and bupivacaine in treatment of de Quervain's disease. A total of 17 patients with symptomatic De Quervain's disease were included in this study. The procedure involved confirmation of diagnosis with ultrasound followed by guided injection of a mixture of 20 mg of triamcinolone (40 mg/ml) and 1 ml of 0.5% bupivacaine. Ultrasound guidance with a high resolution 15-Mhz footprint probe was used for injection into the first dorsal extensor compartment tendon sheath (E1). The response to ultrasound-guided injection was ascertained at the post procedure outpatient clinic appointment according to the follow-up clinic notes. There were 14 female and 3 male patients aged 29 to 74 years. Mean duration of symptoms was 8.9 months. One patient had an atypical septum in the first extensor compartment and the extensor pollicis brevis alone was involved. The mean post-injection follow-up was at 6.75 weeks. One patient was lost to follow-up. Fifteen out of 16 patients had significant symptomatic relief (93.75%). There were no immediate or delayed complications. Recurrence of symptoms was seen in 3 (20%) patients. Ultrasound-guided injection of triamcinolone and bupivacaine is safe and useful in controlling symptoms of De Quervain's disease. Correct needle placement with ultrasound guidance avoids intratendinous injection as well as local complications like fat atrophy and depigmentation.

  14. Image-guided breast biopsy: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, E.A.M., E-mail: lizoflynn@doctors.org.u [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom); Wilson, A.R.M.; Michell, M.J. [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom)

    2010-04-15

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues.

  15. Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results

    International Nuclear Information System (INIS)

    Hakime, Antoine; Deschamps, Frederic; Marques De Carvalho, Enio Garcia; Barah, Ali; Auperin, Anne; Baere, Thierry De

    2012-01-01

    Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid on the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and “in-plane” or “out-of-plane” needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5–60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to

  16. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... be guided by ultrasound, are used to sample cells from organs for laboratory testing help detect the ... in which needles are used to extract sample cells from an abnormal area for laboratory testing. Ultrasound ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... women and their unborn babies. Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  18. Histological diagnosis of ultrasound-visible breast lesions by large core needle biopsy

    International Nuclear Information System (INIS)

    Sanchis-Querol, E.; Valeros, O.; Collado, A.; Gimenez, J.; Yanguas, C.

    1999-01-01

    We present our experience in the histological diagnosis of breast lesions using ultrasound-guided large core needle biopsy (LCNB), assessing its utility as an alternative to excisional biopsy. We have studied retrospectively a series of 146 cases involving the performance of LCNB. The results were comparable with those of FNAB in 59 cases and with those of surgical aspiration biopsy in 105. Of the 113 lesions identified as malignant by percutaneous large core needle aspiration biopsy, 96 were resected. Surgical aspiration biopsy agreed with LCNB in 100% of cases. Of the 33 lesions identified as benign by LCNB, surgical biopsy detected malignancy in 5. The results obtained establish a specificity for LCNB of 100% and a sensitivity of 96%, both of which are superior to the values for FNAB. Thus, this technique can be considered valid for preoperative diagnosis. LCNB is useful in the preoperative diagnosis of breast lesions, making FNAB and surgical biopsy unnecessary. Moreover, it constitutes a significant change in the management of patients with malignant or undetermined breast lesions. (Author) 8 refs

  19. Technical Aspects of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration: CHEST Guideline and Expert Panel Report.

    Science.gov (United States)

    Wahidi, Momen M; Herth, Felix; Yasufuku, Kazuhiro; Shepherd, Ray Wesley; Yarmus, Lonny; Chawla, Mohit; Lamb, Carla; Casey, Kenneth R; Patel, Sheena; Silvestri, Gerard A; Feller-Kopman, David J

    2016-03-01

    Endobronchial ultrasound (EBUS) was introduced in the last decade, enabling real-time guidance of transbronchial needle aspiration (TBNA) of mediastinal and hilar structures and parabronchial lung masses. The many publications produced about EBUS-TBNA have led to a better understanding of the performance characteristics of this procedure. The goal of this document was to examine the current literature on the technical aspects of EBUS-TBNA as they relate to patient, technology, and proceduralist factors to provide evidence-based and expert guidance to clinicians. Rigorous methodology has been applied to provide a trustworthy evidence-based guideline and expert panel report. A group of approved panelists developed key clinical questions by using the PICO (population, intervention, comparator, and outcome) format that addressed specific topics on the technical aspects of EBUS-TBNA. MEDLINE (via PubMed) and the Cochrane Library were systematically searched for relevant literature, which was supplemented by manual searches. References were screened for inclusion, and well-recognized document evaluation tools were used to assess the quality of included studies, to extract meaningful data, and to grade the level of evidence to support each recommendation or suggestion. Our systematic review and critical analysis of the literature on 15 PICO questions related to the technical aspects of EBUS-TBNA resulted in 12 statements: 7 evidence-based graded recommendations and 5 ungraded consensus-based statements. Three questions did not have sufficient evidence to generate a statement. Evidence on the technical aspects of EBUS-TBNA varies in strength but is satisfactory in certain areas to guide clinicians on the best conditions to perform EBUS-guided tissue sampling. Additional research is needed to enhance our knowledge regarding the optimal performance of this effective procedure. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights

  20. Needle autopsy to establish the cause of death in HIV-infected hospitalized adults in Uganda: a comparison to complete autopsy.

    Science.gov (United States)

    Cox, Janneke A; Lukande, Robert L; Kalungi, Sam; Van Marck, Eric; Van de Vijver, Koen; Kambugu, Andrew; Nelson, Ann M; Manabe, Yukari C; Colebunders, Robert

    2014-10-01

    Minimal invasive but accurate methods to establish the cause of death in HIV-infected patients are needed. We studied the agreement in cause of death between blind and ultrasound-guided needle autopsy and complete autopsy in HIV-infected patients in Uganda. We subsequently performed a blind and ultrasound-guided needle autopsy followed by a complete autopsy in HIV-infected adults who died during hospitalization. Two teams of pathologists reviewed the tissue from either the needle autopsies or the complete autopsy and formulated the major diagnoses, that is, diseases directly contributing to death. The primary outcome was concordance in major diagnosis between needle and complete autopsies. We performed 96 blind needle and complete autopsies and 95 ultrasound-guided needle autopsies. Concordance in major diagnosis between blind needle and complete autopsy was 50%. For the main major diagnosis, tuberculosis (TB) concordance was higher (71%; P autopsy identified at least 1 major diagnosis in 60% of patients; and in 46%, there was complete concordance for all major diagnoses. The main reason for discordance was sampling error of the lesion. Concordance with the addition of ultrasound guidance was 52% for all major diagnoses and 79% for TB. Major diagnoses were mainly identified in tissue cores from the liver (76%) and the spleen (82%). Blind needle autopsy identified half of the major diagnosis. The addition of ultrasound guidance did not significantly improve the performance of needle autopsy. Needle autopsy is a valuable method to confirm causes of death in HIV-infected patients, especially for highly prevalent diseases like TB.

  1. Fine needle aspiration cytology of parapharyngeal tumors

    Directory of Open Access Journals (Sweden)

    Mondal Palash

    2009-01-01

    Full Text Available Background: Parapharyngeal tumors are rare and often pose diagnostic difficulties due to their location and plethora of presentations. Objectives: The study was undertaken to study the occurrence in the population and to evaluate the exact nature by fine needle aspiration cytology (FNAC. Materials and Methods: A total of five hundred and six cases of lateral neck lesions were studied over three and half years. Of these 56 suspected parapharyngeal masses were selected by clinical and radiological methods. Cytopathology evaluation was done by fine needle aspiration cytology with computed tomography and ultrasonography guidance wherever necessary. Histopathology confirmation was available in all the cases. Results: On FNAC diagnosis could be established in 54 cases while in two cases the material was insufficient to establish a diagnosis. The tumors encountered were, pleomorphic adenoma (33, schwannoma (3, neurofibroma (11, paraganglioma (5, angiofibroma (1 and adenoid cystic carcinoma (1. Four false positives and two false negative cases were encountered. Overall sensitivity was 96%, with specificity of 99% and accuracy being 98.8%. Conclusions: With proper clinical and radiological assessment, FNAC can be extremely useful in diagnosing most of these lesions except a few which need histopathological and even immunohistochemical confirmation.

  2. Smartphone-Guided Needle Angle Selection During CT-Guided Procedures.

    Science.gov (United States)

    Xu, Sheng; Krishnasamy, Venkatesh; Levy, Elliot; Li, Ming; Tse, Zion Tsz Ho; Wood, Bradford John

    2018-01-01

    In CT-guided intervention, translation from a planned needle insertion angle to the actual insertion angle is estimated only with the physician's visuospatial abilities. An iPhone app was developed to reduce reliance on operator ability to estimate and reproduce angles. The iPhone app overlays the planned angle on the smartphone's camera display in real-time based on the smartphone's orientation. The needle's angle is selected by visually comparing the actual needle with the guideline in the display. If the smartphone's screen is perpendicular to the planned path, the smartphone shows the Bull's-Eye View mode, in which the angle is selected after the needle's hub overlaps the tip in the camera. In phantom studies, we evaluated the accuracies of the hardware, the Guideline mode, and the Bull's-Eye View mode and showed the app's clinical efficacy. A proof-of-concept clinical case was also performed. The hardware accuracy was 0.37° ± 0.27° (mean ± SD). The mean error and navigation time were 1.0° ± 0.9° and 8.7 ± 2.3 seconds for a senior radiologist with 25 years' experience and 1.5° ± 1.3° and 8.0 ± 1.6 seconds for a junior radiologist with 4 years' experience. The accuracy of the Bull's-Eye View mode was 2.9° ± 1.1°. Combined CT and smart-phone guidance was significantly more accurate than CT-only guidance for the first needle pass (p = 0.046), which led to a smaller final targeting error (mean distance from needle tip to target, 2.5 vs 7.9 mm). Mobile devices can be useful for guiding needle-based interventions. The hardware is low cost and widely available. The method is accurate, effective, and easy to implement.

  3. Ultrasound-guided botulinum toxin injections

    Directory of Open Access Journals (Sweden)

    S. E. Khatkova

    2016-01-01

    Full Text Available One of the key conditions for achieving the desirable result during botulinum toxin therapy for muscular dystonia, spasticity, and other diseases accompanied by spasm, pain, and autonomic dysfunction (dystonias, spasticity, etc. is the proper administration of the agent into the muscles directly involved in the pathological process. The exact entry of botulinum toxin into the target muscles is essential for successful and safe treatment because its injection into a normal muscle may cause side effects. The most common errors are the incorrect depth and incorrect direction of a needle on insertion. Therefore, the exact injection of the agent particularly into the shallow and deep muscles is a difficult task even for an experienced specialist and requires the use of controlling methods.The European Consensus on Botulinum Toxin Therapy points out that various injection techniques are needed for the better identification of necessary muscles. However, there are currently no reports on the clear advantage of any technique. In our country, injections using palpation and anatomical landmarks have been widely used in routine practice so far; electromyographic monitoring and electrostimulation have been less frequently applied. In recent years, the new method ultrasound-guided injection has continued to grow more popular. This effective, accessible, and easy-to-use method makes it possible to manage a real-time injection process and to ensure the exact entry of the agent into the muscle. This paper is dedicated to a comparative analysis of different injection methods and to a description of the ultrasound-guided technique and its advantages over others. 

  4. Fine needle aspiration cytology of breast lumps with histopathologic ...

    African Journals Online (AJOL)

    diagnosis of palpable breast lesions, in recent years two types of minimally invasive .... negative predictive value of FNAC as a diagnostic pro- cedure for the entire ... The earliest large scale use of Fine Needle aspiration. Cytology FNAC as a ...

  5. How to achieve ultrasound-guided femoral venous access: the new standard of care in the electrophysiology laboratory.

    Science.gov (United States)

    Wiles, Benedict M; Child, Nicholas; Roberts, Paul R

    2017-06-01

    Bedside vascular ultrasound machines are increasingly available. They are used to facilitate safer vascular access across a number of different specialties. In the electrophysiology laboratory however, where patients are frequently anticoagulated and require the insertion of multiple venous sheaths, anatomical landmark techniques predominate. Despite the high number of vascular complications associated with electrophysiological procedures and the increasing evidence to support its use in electrophysiology, ultrasound remains underutilised. A new standard of care is required. A comprehensive technical report, providing a detailed explanation of this important technique, will provide other electrophysiology centres with the knowledge and justification for adopting ultrasound guidance as their standard practice. We review the increasing body of evidence which demonstrates that routine ultrasound usage can substantially improve the safety of femoral venous access in the electrophysiology laboratory. We offer a comprehensive technical report to guide operators through the process of ultrasound-guided venous access, with a specific focus on the electrophysiology laboratory. Additionally, we detail a novel technique which utilises real-time colour Doppler ultrasound to accurately identify needle tip location during venous puncture. The use of vascular ultrasound to guide femoral venous cannulation is rapid, inexpensive and easily learnt. Ultrasound is readily available and offers the potential to significantly reduce vascular complications in the unique setting of the electrophysiology laboratory. Ultrasound guidance to achieve femoral venous access should be the new standard of care in electrophysiology.

  6. Ultrasound guided supraclavicular block.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2013-09-01

    Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.

  7. The role of ultrasound-guided vacuum-assisted removal of gynecomastia

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Me [Dankook University Hospital, Cheonan (Korea, Republic of)

    2008-02-15

    To evaluate the role of performing ultrasound (US)-guided vacuum-assisted breast biopsies for the treatment (mammotome excision) of gynecomastia. Between November 2005 and December 2006, nine male patients underwent US-guided mammotome excision for eleven cases of true gynecomastia. The patient ages ranged from 14 to 55 years (mean age, 32.3 years). US-guided mammotome excision was performed with an 11-gauge needle in seven cases and an 8-gauge needle in four cases. After the procedure, the cigarette method using gauze packing was performed. The number of samples, procedure time and presence of complications were evaluated. Scheduled follow-up physical and US examinations were performed after three and six months. For 11 cases of US-guided mammotome excision of gynecomastia, the number of samples ranged from 12-126 (mean, 66) and the procedure time ranged from 10-42 minutes (mean time, 25.1 minutes). Clinical significant complications did not occur immediately after the procedure and complications were not seen after a follow-up examination in any of the cases. At the 3-and 6-month follow up examinations, all of the patients showed a normal male physical appearance on a physical examination and there was no evidence of hypoechoic glandular tissues as seen on ultrasonograms. US-guided mammotome excision is effective for the treatment of small, glandular true gynecomastia and is suggested as a new modality to replace the need for surgery or liposuction.

  8. Mixed germ cell tumor of mediastinum/lung masquerading as hemangioma in fine needle biopsy

    Directory of Open Access Journals (Sweden)

    Rathna Nuti

    2013-01-01

    Full Text Available The histological predominance of one component in a germ cell tumor can lead to a mistaken diagnosis. Here, we describe a mediastinal teratoma with predominant vascular proliferation (>90% which on fine needle biopsy was diagnosed as a pulmonary hemangioma. Later, resection specimen revealed other components constituting ~4%, changing the diagnosis while illustrating theimportance of careful evaluation. A 37-year-old Caucasian male with shortness of breath, weight loss, and history of recently resolved pneumonia was diagnosed with hemangioma, after a computed tomography guided fine needle biopsy of a -16.3-cm mediastinal pulmonary mass revealed abundant benign vascular elements. Following tumor excision, ~94% of the sample exhibited predominant vascular elementsThe mass also exhibited rare focal areas of malignant epithelium in a reticular arrangement and undifferentiated pleomorphic cells associated with vascular invasion. These atypical epithelial cells were positive for CD30, pan CK, AFP, β-HCG and CD 117, thusprocuring a diagnosis of mediastinal mixed germ cell tumor. Although mixed germ cell tumors consist of various tissue types, diagnosis can be easily overlooked if one component dominates. Therefore, obtaining adequate representative neoplasm samples, and sectioning the samples thoroughly, searching for coexisting tissue types is critical for accurate diagnosis.

  9. A Comparison of Endoscopic Ultrasound Guided Biopsy and Positron Emission Tomography with Integrated Computed Tomography in Lung Cancer Staging

    DEFF Research Database (Denmark)

    Larsen, Stine Schmidt; Vilmann, P; Krasnik, K

    2009-01-01

    BACKGROUND AND STUDY AIMS: Exact staging of patients with non-small-cell lung cancer (NSCLC) is important to improve selection of resectable and curable patients for surgery. Positron emission tomography with integrated computed tomography (PET/CT) and endoscopic ultrasound guided fine needle...... aspiration biopsy (EUS-FNA) are new and promising methods, but indications in lung cancer staging are controversial. Only few studies have compared the 2 methods. The aim of this study was to assess and compare the diagnostic values of PET/CT and EUS-FNA for diagnosing advanced lung cancer in patients, who...... had both procedures performed. PATIENTS AND METHODS: 27 patients considered to be potential candidates for resection of NSCLC underwent PET/CT and EUS-FNA. Diagnoses were confirmed either by open thoracotomy, mediastinoscopy or clinical follow-up. Advanced lung cancer was defined as tumour...

  10. Ultrasound-Guided Greater Occipital Nerve Blocks and Pulsed Radiofrequency Ablation for Diagnosis and Treatment of Occipital Neuralgia

    OpenAIRE

    VanderHoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-01-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing...

  11. Neurologic Outcomes After Low-Volume, Ultrasound-Guided Interscalene Block and Ambulatory Shoulder Surgery.

    Science.gov (United States)

    Rajpal, Gaurav; Winger, Daniel G; Cortazzo, Megan; Kentor, Michael L; Orebaugh, Steven L

    2016-01-01

    Postoperative neurologic symptoms after interscalene block and shoulder surgery have been reported to be relatively frequent. Reports of such symptoms after ultrasound-guided block have been variable. We evaluated 300 patients for neurologic symptoms after low-volume, ultrasound-guided interscalene block and arthroscopic shoulder surgery. Patients underwent ultrasound-guided interscalene block with 16 to 20 mL of 0.5% bupivacaine or a mix of 0.2% bupivacaine/1.2% mepivacaine solution, followed by propofol/ketamine sedation for ambulatory arthroscopic shoulder surgery. Patients were called at 10 days for evaluation of neurologic symptoms, and those with persistent symptoms were called again at 30 days, at which point neurologic evaluation was initiated. Details of patient demographics and block characteristics were collected to assess any association with persistent neurologic symptoms. Six of 300 patients reported symptoms at 10 days (2%), with one of these patients having persistent symptoms at 30 days (0.3%). This was significantly lower than rates of neurologic symptoms reported in preultrasound investigations with focused neurologic follow-up and similar to other studies performed in the ultrasound era. There was a modest correlation between the number of needle redirections during the block procedure and the presence of postoperative neurologic symptoms. Ultrasound guidance of interscalene block with 16- to 20-mL volumes of local anesthetic solution results in a lower frequency of postoperative neurologic symptoms at 10 and 30 days as compared with investigations in the preultrasound period.

  12. Ultrasound-guided percutaneous cholecysto-cholangiography for the exclusion of biliary atresia in infants

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Kyung Min; Ryeom, Hun Kyu; Choe, Byung Ho; Kim, Kap Cheol; Kim, Jong Yeol; Lee, Jong Min; Kim, Hye Jeong; Lee, Hee Jung [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2006-08-15

    The aim of this study is to determine the feasibility and effectiveness of performing an ultrasound-guided percutaneous cholecysto-cholangiogram (PCC) for excluding biliary atresia as the cause of neonatal jaundice. Between Oct. 2003 and Feb. 2005, six ultrasound-guided PCC procedures were performed to five jaundiced infants (4 females and 1 male; mean age: 60 days old) for whom possibility of biliary atresia could not be ruled out by the DISIDA scan as the cause of their neonatal jaundice. Gallbladder puncture was performed under ultrasound guidance with a 23-gauge needle. Contrast material injection during fluoroscopic examination was performed after dilatation of the gallbladder lumen with normal saline under ultrasound guidance. The criteria used for excluding biliary atresia were complete visualization of the extrahepatic biliary trees and/or contrast excretion into the duodenum. The complications and final diagnosis was assessed according to the clinical and laboratory findings. The procedures were successful in all the patients without any complication. Biliary atresia could be ruled out in all the patients. The final diagnosis was neonatal cytomegalovirus hepatitis in two patients, total parenteral nutrition-associated cholestasis in two patients, and combined cytomegalovirus hepatitis and total parenteral nutrition-associated cholestasis in one patient. Ultrasound-guided PCC is a feasible and effective method for the early definitive exclusion of biliary atresia as the cause of neonatal jaundice. By the technique of injecting normal saline before contrast injection, PCC can be done even in a totally collapsed or very small gallbladder.

  13. Ultrasound-guided percutaneous cholecysto-cholangiography for the exclusion of biliary atresia in infants

    International Nuclear Information System (INIS)

    Shin, Kyung Min; Ryeom, Hun Kyu; Choe, Byung Ho; Kim, Kap Cheol; Kim, Jong Yeol; Lee, Jong Min; Kim, Hye Jeong; Lee, Hee Jung

    2006-01-01

    The aim of this study is to determine the feasibility and effectiveness of performing an ultrasound-guided percutaneous cholecysto-cholangiogram (PCC) for excluding biliary atresia as the cause of neonatal jaundice. Between Oct. 2003 and Feb. 2005, six ultrasound-guided PCC procedures were performed to five jaundiced infants (4 females and 1 male; mean age: 60 days old) for whom possibility of biliary atresia could not be ruled out by the DISIDA scan as the cause of their neonatal jaundice. Gallbladder puncture was performed under ultrasound guidance with a 23-gauge needle. Contrast material injection during fluoroscopic examination was performed after dilatation of the gallbladder lumen with normal saline under ultrasound guidance. The criteria used for excluding biliary atresia were complete visualization of the extrahepatic biliary trees and/or contrast excretion into the duodenum. The complications and final diagnosis was assessed according to the clinical and laboratory findings. The procedures were successful in all the patients without any complication. Biliary atresia could be ruled out in all the patients. The final diagnosis was neonatal cytomegalovirus hepatitis in two patients, total parenteral nutrition-associated cholestasis in two patients, and combined cytomegalovirus hepatitis and total parenteral nutrition-associated cholestasis in one patient. Ultrasound-guided PCC is a feasible and effective method for the early definitive exclusion of biliary atresia as the cause of neonatal jaundice. By the technique of injecting normal saline before contrast injection, PCC can be done even in a totally collapsed or very small gallbladder

  14. Diagnostic accuracy of fine needle aspiration cytology in patients ...

    African Journals Online (AJOL)

    Objective: To estimate the sensitivity and specificity of FNAC in detecting malignancy for thyroid disease using histopathology ... thyroid carcinoma being the most predominant type and colloid goiter was the most predominant benign thyroid disease. The sensitivity ..... tic accuracy of fine needle aspiration cytology in thyroid.

  15. Thyroid fine-needle aspiration and the bethesda classification system

    DEFF Research Database (Denmark)

    Larsen, Louise Vølund; Egset, Alice Viktoria; Holm, Camilla

    2018-01-01

    INTRODUCTION: Fine-needle aspiration (FNA) is a cornerstone in diagnosing thyroid nodules. For decades, Danish FNA have been categorised into the groups: “FNA not per-formed”, “Inadequate”, “Cystic”, “Inconclusive”, “Benign”, “Suspicious”, “Malignant” and “Information missing”. Internationally...

  16. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    International Nuclear Information System (INIS)

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L.

    2010-01-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  17. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    Science.gov (United States)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  18. Real-time image-based B-mode ultrasound image simulation of needles using tensor-product interpolation.

    Science.gov (United States)

    Zhu, Mengchen; Salcudean, Septimiu E

    2011-07-01

    In this paper, we propose an interpolation-based method for simulating rigid needles in B-mode ultrasound images in real time. We parameterize the needle B-mode image as a function of needle position and orientation. We collect needle images under various spatial configurations in a water-tank using a needle guidance robot. Then we use multidimensional tensor-product interpolation to simulate images of needles with arbitrary poses and positions using collected images. After further processing, the interpolated needle and seed images are superimposed on top of phantom or tissue image backgrounds. The similarity between the simulated and the real images is measured using a correlation metric. A comparison is also performed with in vivo images obtained during prostate brachytherapy. Our results, carried out for both the convex (transverse plane) and linear (sagittal/para-sagittal plane) arrays of a trans-rectal transducer indicate that our interpolation method produces good results while requiring modest computing resources. The needle simulation method we present can be extended to the simulation of ultrasound images of other wire-like objects. In particular, we have shown that the proposed approach can be used to simulate brachytherapy seeds.

  19. Simulation and training of ultrasound supported anaesthesia: a low-cost approach

    Science.gov (United States)

    Schaaf, T.; Lamontain, M.; Hilpert, J.; Schilling, F.; Tolxdorff, T.

    2010-03-01

    The use of ultrasound imaging technology during techniques of peripheral nerve blockade offers several clinical benefits. Here we report on a new method to educate residents in ultrasound-guided regional anesthesia. The daily challenge for the anesthesiologists is the 3D angle-depending handling of the stimulation needle and the ultrasound probe while watching the 2D ultrasound image on the monitor. Purpose: Our approach describes how a computer-aided simulation and training set for ultrasound-guided regional anesthesia could be built based on wireless low-cost devices and an interactive simulation of a 2D ultrasound image. For training purposes the injection needle and the ultrasound probe are replaced by wireless Bluetooth-connected 3D tracking devices, which are embedded in WII-mote controllers (Nintendo-Brand). In correlation to the tracked 3D positions of the needle and transducer models the visibility and position of the needle should be simulated in the 2D generated ultrasound image. Conclusion: In future, this tracking and visualization software module could be integrated in a more complex training set, where complex injection paths could be trained based on a 3D segmented model and the training results could be part of a curricular e-learning module.

  20. EUS – Fine- Needle Aspiration Biopsy (FNAB in the Diagnosis of Pancreatic Adenocarcinoma: A Review

    Directory of Open Access Journals (Sweden)

    Kalogeraki Alexandra

    2016-03-01

    Full Text Available Solid masses of the pancreas represent a variety of benign and malignant neoplasms of the exocrine and endocrine tissues of the pancreas. A tissue diagnosis is often required to direct therapy in the face of uncertain diagnosis or if the patient is not a surgical candidate either due to advanced disease or comorbidities. Endoscopic ultrasound (EUS is a relatively new technology that employs endoscopy and high-frequency ultrasound (US. EUS involves imaging of the pancreatic head and the uncinate from the duodenum and imaging of the body and tail from the stomach. It has been shown to be a highly sensitive method for the detection of pancreatic masses. It is superior to extracorporeal US and computed tomographic (CT scans, especially when the pancreatic tumor is smaller than 2-3 cm. Although EUS is highly sensitive in detecting pancreatic solid masses, its ability to differentiate between inflammatory masses and malignant disease is limited. Endoscopic retrograde cholangiopancreatography (ERCP brushing, CT-guided biopsies, and transabdominal ultrasound (US have been the standard nonsurgical methods for obtaining a tissue diagnosis of pancreatic lesions, but a substantial false-negative rate has been reported. Transabdominal US-guided fine-needle aspiration biopsy (US-FNAB has been used for tissue diagnosis in patients with suspected pancreatic carcinoma. It has been shown to be highly specific, with no false-positive diagnoses. With the advent of curvilinear echoendoscopes, transgastric and transduodenal EUS-FNAB of the pancreas have become a reality EUS with FNAB has revolutionized the ability to diagnose and stage cancers of the gastrointestinal tract and assess the pancreas. Gastrointestinal cancers can be looked at with EUS and their depth of penetration into the intestinal wall can be determined. Any suspicious appearing lymph nodes can be biopsied using EUS/FNAB. The pancreas is another organ that is well visualized with EUS. Abnormalities

  1. Ultrasound-guided biopsy of transplanted pancreas: evaluation of 20 cases

    Directory of Open Access Journals (Sweden)

    Marcel Vieira da Nóbrega

    2009-03-01

    Full Text Available Objective: To report the experience with percutaneous biopsies of pancreatic grafts guided by ultrasonography. Methods: Series of cases referred from outpatient’s clinic for biopsy of pancreas transplant, between December 2006 and March 2008. Data were collected from medical electronic records for age, sex and histopathology. The indication for the procedure was obtained from medical and laboratory records. Doppler ultrasonography was performed for control and to guide biopsy in real time. Rresults: Twenty patients referred for biopsy of their transplanted pancreas over a one-year period were evaluated. In one patient, biopsy was not performed for having no safe access for ultrasound. It was used 18 gauge needles, mostly automatic-cut type. The main indications were increased blood glucose and pancreatic enzyme levels as well as reduction of urinary amylase. The sonographic aspect of the pancreatic graft was normal in 18 cases. In all 19 biopsies performed, satisfactory samples for histopathological study were obtained. There were no complications. Cconclusions: This series of cases demonstrated low sensitivity and specificity of ultrasound in diagnosis of pancreatic transplants disorders, but showed to be very useful to guide transplanted pancreas biopsies. Although no complications occurred in this experience, the risk-benefit relation should always be assessed for every patient.

  2. Ultrasound-Guided Cannulation: Time to Bring Subclavian Central Lines Back

    Directory of Open Access Journals (Sweden)

    Talayeh Rezayat, DO, MPH

    2016-03-01

    Full Text Available Despite multiple advantages, subclavian vein (SCV cannulation via the traditional landmark approach has become less used in comparison to ultrasound (US guided internal jugular catheterization due to a higher rate of mechanical complications. A growing body of evidence indicates that SCV catheterization with real-time US guidance can be accomplished safely and efficiently. While several cannulation approaches with real-time US guidance have been described, available literature suggests that the infraclavicular, longitudinal “in-plane” technique may be preferred. This approach allows for direct visualization of needle advancement, which reduces risk of complications and improves successful placement. Infraclavicular SCV cannulation requires simultaneous use of US during needle advancement, but for an inexperienced operator, it is more easily learned compared to the traditional landmark approach. In this article, we review the evidence supporting the use of US guidance for SCV catheterization and discuss technical aspects of the procedure itself.

  3. Guided interventions in musculoskeletal ultrasound: what's the evidence?

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, J., E-mail: jdavidson@doctors.org.u [St Richard' s Hospital, Spitalfield Lane, Chichester, West Sussex (United Kingdom); Jayaraman, S. [St Richard' s Hospital, Spitalfield Lane, Chichester, West Sussex (United Kingdom)

    2011-02-15

    Increasing histological and radiological understanding of the processes involved in soft-tissue injury is leading to novel targeted treatments. A number of reviews have recommended that these treatments should be performed with image guidance. This review describes current ultrasound-guided interventions and injections, together with the level of evidence for these. Discussion of guided interventions will include; percutaneous lavage (barbotage), brisement, dry needling, electrocoagulation, and of guided injections; corticosteroids, autologous substances (blood and platelet rich plasma), sclerosants, and prolotherapy (hyperosmolar dextrose). Representative imaging illustrating some of these techniques is included for correlation with the methods described. As these procedures are often performed in sportspeople, it is essential that the radiologist is aware of prohibited substances and methods outlined in an annual publication from the World Anti-Doping Association (WADA). Finally, future directions, including the use of autologous substances, mesenchymal and stem cells will be discussed.

  4. Is percutaneous fine-needle biopsy a hazard? An update

    International Nuclear Information System (INIS)

    Smith, E.H.

    1987-01-01

    Fine-needle biopsy (FNB) has become a commonplace diagnostic procedure in most radiology departments with the assumption that risks are nonexistent. Animal experiments conclusively indicate the leakage of tumor cells after biopsy, but clinical evidence appears to point to a paucity of complications. In a prior review of the literature, two needle tract seedings (NTS) and two fatalities after FNB were discovered. A questionnaire at that time uncovered three more cases of NTS and four deaths. An updated literature search and questionnaire showed an additional 14 cases of NTS and nine deaths. An analysis of the date are reported

  5. [Fine needle aspiration cytology of mammography screening

    DEFF Research Database (Denmark)

    Engvad, B.; Laenkholm, A.V.; Schwartz, Thue W.

    2009-01-01

    INTRODUCTION: In the year 2000 a quality assurance programme for the preoperative breast diagnostics was introduced in Denmark. The programme was based on the "European guidelines for quality assurance in breast cancer screening and diagnosis" where - among other measures - five cytological...... diagnostic classes were introduced. The aim of this study was to evaluate the quality assurance programme in a screening population to determine whether fine needle aspiration cytology (FNAC) as first choice remains a useful tool in the preoperative diagnostics, or if needle core biopsy should be the first...... of 66% of the 783 FNACs had a malignant cytology diagnosis, which in 99% of the cases turned out to be the correct diagnosis. Four lesions were false positives all of which represented benign proliferative breast diseases. The surgical procedures in these cases were either excisional biopsy...

  6. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel (Dept. of Radiology, Medical Faculty, Univ. Duesseldorf, Duesseldorf (Germany)), email: Patric.Kroepil@med.uni-duesseldorf.de

    2011-10-15

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 +- 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 +- 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 +- 33 vs. n = 126 +- 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  7. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    International Nuclear Information System (INIS)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel

    2011-01-01

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 ± 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 ± 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 ± 33 vs. n = 126 ± 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  8. Sonographic features and ultrasonography-guided fine-needle aspiration of metastases to the thyroid gland

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jung Hyun; Kim, Eun Kyung; Kwak, Jin Young; Moon, Hee Jung; Kim, Ga Ram [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-03-15

    To evaluate the characteristic ultrasonographic (US) features of metastatic carcinoma to the thyroid, and how accurate US features and ultrasonography-guided fine-needle aspiration (US-FNA) are for the diagnosis of thyroid metastases. Twenty-three thyroid lesions in 23 patients (mean age, 66.7 years; range, 46 to 85 years) that had been diagnosed as thyroid metastases were included. The composition, echogenicity, margin, shape, presence of calcifications, underlying parenchymal echotexture, and vascularity were analyzed in US images of the thyroid metastases. Final US assessments were categorized into probably benign and suspicious malignancy. The presence of suspicious metastatic cervical lymph nodes was noted. The medical records, US-FNA cytology, and pathology reports of these patients were retrospectively reviewed. Of the 23 thyroid lesions, the general US appearance was mass-forming in 21 (91.3%) and non-mass-forming in 2 (8.7%). All 23 lesions showed a solid tumor composition. Common US features among the 21 mass-forming thyroid metastases were hypoechogenicity (81.0%), non-circumscribed margins (90.5%), no calcifications (76.2%), and parallel shape (81.0%). Suspicious cervical lymph nodes were present in 18 patients (78.3%). Of the 23 lesions, 21 (91.3%) were classified as suspicious malignancy, and 2 (8.7%) as probably benign. US-FNA showed diagnostic results specific for metastases in 21 of the 22 patients (95.5%) who had undergone US-FNA. Common US features in thyroid metastasis were hypoechogenicity, non-circumscribed margins, no calcifications, parallel shape, and the presence of suspicious cervical lymph nodes. US-FNA can be effectively used in the diagnosis of thyroid metastasis, preventing unnecessary surgery.

  9. A novel concept for continuous peripheral nerve blocks. Presentation of a new ultrasound-guided device

    DEFF Research Database (Denmark)

    Rothe, C; Steen-Hansen, C; Madsen, M H

    2015-01-01

    positioning as well as during later in-plane readjustment of the catheter. We tested the system in the popliteal region of two fresh cadavers in a preliminary proof of concept study. RESULTS: Both initial placement and secondary readjustment were precise, judged by the catheter orifices placed close......BACKGROUND: Existing techniques for placing and maintaining the position of peripheral nerve catheters are associated with variable success rates and frequent secondary failures. These factors may affect the clinical efficacy and usefulness of peripheral nerve catheters. METHODS: We developed a new...... concept and prototype for ultrasound-guided in-plane positioning and readjustment of peripheral nerve catheters (patent pending). The integrated catheter-needle prototype comprises three parts: a curved needle, a catheter with clear echogenic markings attached to the needle tail and a detachable hub...

  10. Is ultrasound-guided injection more effective in chronic subacromial bursitis?

    Science.gov (United States)

    Hsieh, Lin-Fen; Hsu, Wei-Chun; Lin, Yi-Jia; Wu, Shih-Hui; Chang, Kae-Chwen; Chang, Hsiao-Lan

    2013-12-01

    Although ultrasound (US)-guided subacromial injection has shown increased accuracy in needle placement, whether US-guided injection produces better clinical outcome is still controversial. Therefore, this study aimed to compare the efficacy of subacromial corticosteroid injection under US guidance with palpation-guided subacromial injection in patients with chronic subacromial bursitis. Patients with chronic subacromial bursitis were randomized to a US-guided injection group and a palpation-guided injection group. The subjects in each group were injected with a mixture of 0.5 mL dexamethasone suspension and 3 mL lidocaine into the subacromial bursa. The primary outcome measures were the visual analog scale for pain and active and passive ranges of motion of the affected shoulder. Secondary outcome measures were the Shoulder Pain and Disability Index, the Shoulder Disability Questionnaire, and the 36-item Short-Form Health Survey (SF-36). The primary outcome measures were evaluated before, immediately, 1 wk, and 1 month after the injection; the secondary outcome measures were evaluated before, 1 wk, and 1 month after the injection. Of the 145 subjects screened, 46 in each group completed the study. Significantly greater improvement in passive shoulder abduction and in physical functioning and vitality scores on the SF-36 were observed in the US-guided group. The pre- and postinjection within-group comparison revealed significant improvement in the visual analog scale for pain and range of motion, as well as in the Shoulder Pain and Disability Index, Shoulder Disability Questionnaire, and SF-36 scores, in both groups. The US-guided subacromial injection technique produced significantly greater improvements in passive shoulder abduction and in some items of the SF-36. US is effective in guiding the needle into the subacromial bursa in patients with chronic subacromial bursitis.

  11. Comparison of the coracoid and retroclavicular approaches for ultrasound-guided infraclavicular brachial plexus block.

    Science.gov (United States)

    Kavrut Ozturk, Nilgun; Kavakli, Ali Sait

    2017-08-01

    This prospective randomized study compared the coracoid and retroclavicular approaches to ultrasound-guided infraclavicular brachial plexus block (IBPB) in terms of needle tip and shaft visibility and quality of block. We hypothesized that the retroclavicular approach would increase needle tip and shaft visibility and decrease the number of needle passes compared to the coracoid approach. A total of 100 adult patients who received IBPB block for upper limb surgery were randomized into two groups: a coracoid approach group (group C) and a retroclavicular approach group (group R). In group C, the needle was inserted 2 cm medial and 2 cm inferior to the coracoid process and directed from ventral to dorsal. In group R, the needle insertion point was posterior to the clavicle and the needle was advanced from cephalad to caudal. All ultrasound images were digitally stored for analysis. The primary aim of the present study was to compare needle tip and shaft visibility between the coracoid approach and retroclavicular approach in patients undergoing upper limb surgery. The secondary aim was to investigate differences between the two groups in the number of needle passes, sensory and motor block success rates, surgical success rate, block performance time, block performance-related pain, patient satisfaction, use of supplemental local anesthetic and analgesic, and complications. Needle tip visibility and needle shaft visibility were significantly better in group R (p = 0.040, p = 0.032, respectively). Block performance time and anesthesia-related time were significantly shorter in group R (p = 0.022, p = 0.038, respectively). Number of needle passes was significantly lower in group R (p = 0.044). Paresthesia during block performance was significantly higher in group C (p = 0.045). There were no statistically significant differences between the two groups in terms of sensory or motor block success, surgical success, block-related pain, and patient satisfaction

  12. Neuroprotective effects of ultrasound-guided nerve growth factor injections after sciatic nerve injury

    Directory of Open Access Journals (Sweden)

    Hong-fei Li

    2015-01-01

    Full Text Available Nerve growth factor (NGF plays an important role in promoting neuroregeneration after peripheral nerve injury. However, its effects are limited by its short half-life; it is therefore important to identify an effective mode of administration. High-frequency ultrasound (HFU is increasingly used in the clinic for high-resolution visualization of tissues, and has been proposed as a method for identifying and evaluating peripheral nerve damage after injury. In addition, HFU is widely used for guiding needle placement when administering drugs to a specific site. We hypothesized that HFU guiding would optimize the neuroprotective effects of NGF on sciatic nerve injury in the rabbit. We performed behavioral, ultrasound, electrophysiological, histological, and immunohistochemical evaluation of HFU-guided NGF injections administered immediately after injury, or 14 days later, and compared this mode of administration with intramuscular NGF injections. Across all assessments, HFU-guided NGF injections gave consistently better outcomes than intramuscular NGF injections administered immediately or 14 days after injury, with immediate treatment also yielding better structural and functional results than when the treatment was delayed by 14 days. Our findings indicate that NGF should be administered as early as possible after peripheral nerve injury, and highlight the striking neuroprotective effects of HFU-guided NGF injections on peripheral nerve injury compared with intramuscular administration.

  13. Endoscopic ultrasound guided injection of iron oxide magnetic nanoparticles for liver and pancreas

    DEFF Research Database (Denmark)

    Ungureanu, Bogdan Silviu; Pirici, Daniel; Margaritescu, Claudiu

    2016-01-01

    )-guidance, both systemically and locally in the liver and pancreas in order to study new potential therapies for liver and pancreatic tumors. MATERIAL AND METHODS: Six domestic pigs were used for our study design, and divided into three groups: two were injected in the portal vein, and other four were subjected...... to local exposure of IONs in the liver and pancreas, two each. The pigs were on a 7 days follow-up and necropsy was performed with their organs harvested. A 3T MRI scan was also performed. RESULTS: All animals underwent an endoscopic ultrasound fine needle injection (EUS-FNI) procedure without any...

  14. Radiological and cytological correlation of neoplastic lesions of the breast diagnosed by fine needle aspiration biopsy guided with ultrasound at the Hospital San Juan de Dios in the year 2009

    International Nuclear Information System (INIS)

    Madriz Meza, Wendy P.

    2011-01-01

    Mortality from breast cancer has been increased, going on to occupy the first place of the malignant neoplasms in women with a percentage increase of over 45% in 10 years. A bibliographic search demonstrates that have not been performed works that allow to establish the clinical and radiological characteristics of the lesions who have been diagnosed as mammary neoplasms by fine needle aspiration biopsy at the Hospital San Juan de Dios. A observational job, descriptive, longitudinal, retrospective is pretended to perform, to provide an instrument of guidance to the radiologist about the characteristics of alarm on a breast lesion. Female patients ascribed to the Hospital San Juan de Dios, with breast cancer diagnosed by guided fine needle puncture with echography during the year 2009 are included in the study. Data from 39 patients that fulfilled with all the inclusion criteria were presented. The data obtained were collected by reviewing of clinical records; which were found only women, who in their majority were from the province of San Jose, the most affected age group by the five-year periods has been of 45-49 years, followed by the groups between 40-44 years and 50-54 years. The greater part of cases has treated of unique injuries, almost all have been unilateral and measure the size of all the lesions was 21 mm. The injuries have been primarily in the right breast and the upper outer quadrant. The level of radiological success has been good in cases where was used the BIRADS, because it was classified with 4c or 5 to 52,4% of cases, however, it should be noted that in 17 of 39 cases were not properly categorized BIRADS. The main conclusions of this study are: women whose ages are between 45 and 55 years have been especially prone to mammary neoplasms, these lesions are found primarily in upper outer quadrants and measured more than 2 cm. The health problems generated in the patients with these diagnoses have made important to prioritize your attention once

  15. Analysis of a Steerable Needle for Fine Needle Aspiration and Biopsy: Efficiency and Radiation Dose Compared With a Conventional Straight Needle.

    Science.gov (United States)

    Rutigliano, Sandra; Abraham, John A; Kenneally, Barry E; Zoga, Adam C; Nevalainen, Mika; Roedl, Johannes B

    Percutaneous computed tomography (CT)-guided needle biopsy has proven to be an efficacious method for sampling of many soft tissue lesions, especially deep-seated masses in the abdomen and pelvis. This study sought to test the potential for a novel steerable needle to improve localization and to reduce procedure duration and radiation dose compared with a conventional straight needle. A fresh, raw meat sample (lean bovine flank) was imbedded with cylindrical radiopaque and radiolucent obstacles designed to simulate vessels (radiolucent objects) and bones (radiopaque objects) on CT. A pit-containing olive (partially radiopaque) was imbedded beyond the obstacles to represent the target. Two sites on the surface of the meat were selected and marked to determine initial needle placement. Two radiologists with different levels of experience proceeded to position a straight needle and the steerable needle from each skin site to the target using CT guidance as efficiently as possible, avoiding the obstacles. The total positioning time, the number of CT scans required for positioning, and the number of repositioning events (partial withdrawal followed by advancement) were tracked for the straight and steerable needles. For the straight needle, total time to reach the target was 499 to 667 seconds (mean, 592 seconds); for the steerable needle, total time to reach the target was 281 to 343 seconds (mean, 309 seconds), on average, 48% lower. The number of CT scans needed for needle positioning averaged 6.25 for the straight needle and 3.5 for the steerable needle, which is 44% lower. Repositioning events (withdrawing and readvancing the needle) ranged from 3 to 10 for the straight needle (mean, 6.5) and 0 for the steerable needle. Using an in vitro model embedded with obstacles, the steerable needle performed better than a straight needle with regard to procedure time, needle repositioning events, and CT scans required for placement.

  16. Greater physician involvement improves coding outcomes in endobronchial ultrasound-guided transbronchial needle aspiration procedures.

    Science.gov (United States)

    Pillai, Anilkumar; Medford, Andrew R L

    2013-01-01

    Correct coding is essential for accurate reimbursement for clinical activity. Published data confirm that significant aberrations in coding occur, leading to considerable financial inaccuracies especially in interventional procedures such as endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). Previous data reported a 15% coding error for EBUS-TBNA in a U.K. service. We hypothesised that greater physician involvement with coders would reduce EBUS-TBNA coding errors and financial disparity. The study was done as a prospective cohort study in the tertiary EBUS-TBNA service in Bristol. 165 consecutive patients between October 2009 and March 2012 underwent EBUS-TBNA for evaluation of unexplained mediastinal adenopathy on computed tomography. The chief coder was prospectively electronically informed of all procedures and cross-checked on a prospective database and by Trust Informatics. Cost and coding analysis was performed using the 2010-2011 tariffs. All 165 procedures (100%) were coded correctly as verified by Trust Informatics. This compares favourably with the 14.4% coding inaccuracy rate for EBUS-TBNA in a previous U.K. prospective cohort study [odds ratio 201.1 (1.1-357.5), p = 0.006]. Projected income loss was GBP 40,000 per year in the previous study, compared to a GBP 492,195 income here with no coding-attributable loss in revenue. Greater physician engagement with coders prevents coding errors and financial losses which can be significant especially in interventional specialties. The intervention can be as cheap, quick and simple as a prospective email to the coding team with cross-checks by Trust Informatics and against a procedural database. We suggest that all specialties should engage more with their coders using such a simple intervention to prevent revenue losses. Copyright © 2013 S. Karger AG, Basel.

  17. Laser Generated Leaky Acoustic Waves for Needle Visualization.

    Science.gov (United States)

    Wu, Kai-Wen; Wang, Yi-An; Li, Pai-Chi

    2018-04-01

    Ultrasound (US)-guided needle operation is usually used to visualize both tissue and needle position such as tissue biopsy and localized drug delivery. However, the transducer-needle orientation is limited due to reflection of the acoustic waves. We proposed a leaky acoustic wave method to visualize the needle position and orientation. Laser pulses are emitted on top of the needle to generate acoustic waves; then, these acoustic waves propagate along the needle surface. Leaky wave signals are detected by the US array transducer. The needle position can be calculated by phase velocities of two different wave modes and their corresponding emission angles. In our experiments, a series of needles was inserted into a tissue mimicking phantom and porcine tissue to evaluate the accuracy of the proposed method. The results show that the detection depth is up to 51 mm and the insertion angle is up to 40° with needles of different diameters. It is demonstrated that the proposed approach outperforms the conventional B-mode US-guided needle operation in terms of the detection range while achieving similar accuracy. The proposed method reveals the potentials for further clinical applications.

  18. Existing Evidence on Ultrasound-Guided Injections in Sports Medicine.

    Science.gov (United States)

    Daniels, Eldra W; Cole, David; Jacobs, Bret; Phillips, Shawn F

    2018-02-01

    Office-based ultrasonography has become increasingly available in many settings, and its use to guide joint and soft tissue injections has increased. Numerous studies have been conducted to evaluate the use of ultrasound-guided injections over traditional landmark-guided injections, with a rapid growth in the literature over the past few years. A comprehensive review of the literature was conducted to demonstrate increased accuracy of ultrasound-guided injections regardless of anatomic location. In the upper extremity, ultrasound-guided injections have been shown to provide superior benefit to landmark-guided injections at the glenohumeral joint, the subacromial space, the biceps tendon sheath, and the joints of the hand and wrist. Ultrasound-guided injections of the acromioclavicular and the elbow joints have not been shown to be more efficacious. In the lower extremity, ultrasound-guided injections at the knee, ankle, and foot have superior efficacy to landmark-guided injections. Conclusive evidence is not available regarding improved efficacy of ultrasound-guided injections of the hip, although landmark-guided injection is performed less commonly at the hip joint. Ultrasound-guided injections are overall more accurate than landmark-guided injections. While current studies indicate that ultrasound guidance improves efficacy and cost-effectiveness of many injections, these studies are limited and more research is needed.

  19. In-Plane Ultrasound-Guided Knee Injection Through a Lateral Suprapatellar Approach: A Safe Technique.

    Science.gov (United States)

    Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H

    2017-06-01

    This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.

  20. In-plane ultrasonic needle tracking using a fiber-optic hydrophone

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E. [Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT (United Kingdom); Mari, Jean Martial [Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom and GePaSud, University of French Polynesia, Faa’a 98702, French Polynesia (France); West, Simeon J. [Department of Anaesthesia, University College Hospital, Main Theatres, Maple Bridge Link Corridor, Podium 3, 235 Euston Road, London NW1 2BU (United Kingdom); Ginsberg, Yuval; David, Anna L. [Institute for Women’s Health, University College London, 86-96 Chenies Mews, London WC1E 6HX (United Kingdom); Ourselin, Sebastien [Center for Medical Imaging Computing, University College London, Gower Street, London WC1E 6BT (United Kingdom)

    2015-10-15

    the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.

  1. Endobronchial ultrasound-guided transbronchial needle aspiration for lung cancer diagnosis and staging in 179 patients

    Directory of Open Access Journals (Sweden)

    Antonio Bugalho

    2013-09-01

    Full Text Available Background: Linear endobronchial ultrasound-guided transbronchial needle aspiration (eBUStBNA is an important minimally invasive procedure for non-small cell lung cancer (NScLc staging. It is also a valid method for diagnosing extraluminal lesions adjacent to the tracheobronchial tree. Aim: to evaluate our eBUS-tBNA performance regarding diagnostic yield, safety and learning curve for lung cancer diagnosis and staging. Material and methods: All patients undergoing eBUS-tBNA for lung cancer diagnosis or staging were included. they were divided into three different groups: paratracheal and parabronchial masses sent for diagnosis (Group 1; peripheral lung lesions with abnormal mediastinal lymph nodes sent for diagnosis and staging (Group 2; NScLc patients sent for mediastinal staging (Group 3. the learning curve was assessed for yield, accuracy, procedure time, size and number of lesions punctured per patient Results: A total of 179 patients were included and 372 lesions were punctured. the overall yield and accuracy were 88% and 92.7%, respectively. In Group 1, eBUS-tBNA was performed in 48 patients and sensitivity was 86.1% and accuracy was 87.5%. For the 87 patients included in Group 2, yield was 86.7%, accuracy was 93.1% and cancer prevalence was 51.7%. the diagnostic yield and accuracy in Group 3 was 95% and 97.7% respectively. eBUS-tBNA practice led to an increase number of sites punctured per patient in a shorter time, without complications. Conclusion: eBUS-tBNA is an effective method for diagnosing and staging lung cancer patients. the procedure is clearly safe. Handling and performance improves with the number of procedures executed. Resumo: Introdução: A punção aspirativa transbrônquica guiada por ecoendoscopia brônquica linear (eBUS-tBNA é um importante procedimento minimamente invasivo para o estadiamento do cancro do pulmão de não pequenas células (cPNPc. É, também, um método válido para o diagnóstico de les

  2. The role of ultrasound guided percutaneous needle aspiration and lavage (barbotage in the treatment of calcific tendinitis

    Directory of Open Access Journals (Sweden)

    Gamal Niazi

    2015-03-01

    Conclusion: Ultrasound guided aspiration and lavage (barbotage is a highly effective, less aggressive method of treatment in cases of calcific tendinosis, especially for cases with severe pain that does not respond to other conservative methods.

  3. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  4. Derivation of a Performance Checklist for Ultrasound-Guided Arthrocentesis Using the Modified Delphi Method.

    Science.gov (United States)

    Kunz, Derek; Pariyadath, Manoj; Wittler, Mary; Askew, Kim; Manthey, David; Hartman, Nicholas

    2017-06-01

    Arthrocentesis is an important skill for physicians in multiple specialties. Recent studies indicate a superior safety and performance profile for this procedure using ultrasound guidance for needle placement, and improving quality of care requires a valid measurement of competency using this modality. We endeavored to create a validated tool to assess the performance of this procedure using the modified Delphi technique and experts in multiple disciplines across the United States. We derived a 22-item checklist designed to assess competency for the completion of ultrasound-guided arthrocentesis, which demonstrated a Cronbach's alpha of 0.89, indicating an excellent degree of internal consistency. Although we were able to demonstrate content validity for this tool, further validity evidence should be acquired after the tool is used and studied in clinical and simulated contexts. © 2017 by the American Institute of Ultrasound in Medicine.

  5. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer

    DEFF Research Database (Denmark)

    Konge, Lars; Vilmann, P; Clementsen, P

    2012-01-01

    Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was to explore the reliabilit...... and validity of a newly developed EUS Assessment Tool (EUSAT) designed to measure competence in EUS - FNA for mediastinal staging of NSCLC....

  6. Ultrasound-guided facet block to low back pain: a case report

    Directory of Open Access Journals (Sweden)

    Ana Ellen Q. Santiago

    2014-07-01

    Full Text Available BACKGROUND: Osteoarthrosis is a common cause of low back pain. The diagnosis is clinical and can be confirmed by imaging studies. Pain treatment and confirmation of diagnosis are made by intra-articular injection of corticosteroid and by local anesthetic use, due to clinical improvement. A direct monitoring of the procedure can be done under fluoroscopy, a classic technique, or else by an ultrasound-guided procedure. CASE REPORT: Female patient, 88 years old, 1.68 m and 72 kg, with facet osteoarthrosis at L2-L3, L3-L4 and L4-L5 for two years. On physical examination, she exhibited pain on lateralization and spinal extension. We opted in favor of an ultrasound-guided facet joint block. A midline spinal longitudinal scan was obtained, with identification of the desired joint space at L3-L4. A 25 G needle was inserted into the skin by the echographic off-plane ultrasound technique. 1 mL of contrast was administered, with confirmation by fluoroscopy. After aspiration of the contrast, 1 mL of solution containing 0.25% bupivacaine hydrochloride and 10 mg of methylprednisolone acetate was injected. Injections into L3-L4, L2-L3 and L1-L2 to the right were applied. CONCLUSIONS: The visualization of the facet joint by ultrasound involves minimal risk, besides reduction of radiation. This option is suitable for a large part of the population. However, fluoroscopy and computed tomography remain as monitoring techniques indicated for patients with specific characteristics, such as obesity, severe degenerative diseases and anatomical malformations, in which the ultrasound technique is still in need of further study.

  7. Enabling image fusion for a CT guided needle placement robot

    Science.gov (United States)

    Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Velusamy, Gnanasekar; Puhazhendi, Kaliyappan; Wood, Bradford J.

    2017-03-01

    Purpose: This study presents development and integration of hardware and software that enables ultrasound (US) and computer tomography (CT) fusion for a FDA-approved CT-guided needle placement robot. Having real-time US image registered to a priori-taken intraoperative CT image provides more anatomic information during needle insertion, in order to target hard-to-see lesions or avoid critical structures invisible to CT, track target motion, and to better monitor ablation treatment zone in relation to the tumor location. Method: A passive encoded mechanical arm is developed for the robot in order to hold and track an abdominal US transducer. This 4 degrees of freedom (DOF) arm is designed to attach to the robot end-effector. The arm is locked by default and is released by a press of button. The arm is designed such that the needle is always in plane with US image. The articulated arm is calibrated to improve its accuracy. Custom designed software (OncoNav, NIH) was developed to fuse real-time US image to a priori-taken CT. Results: The accuracy of the end effector before and after passive arm calibration was 7.07mm +/- 4.14mm and 1.74mm +/-1.60mm, respectively. The accuracy of the US image to the arm calibration was 5mm. The feasibility of US-CT fusion using the proposed hardware and software was demonstrated in an abdominal commercial phantom. Conclusions: Calibration significantly improved the accuracy of the arm in US image tracking. Fusion of US to CT using the proposed hardware and software was feasible.

  8. Fine needle aspiration cytology: sensitivity and specificity in thyroid lesions

    International Nuclear Information System (INIS)

    Musani, M.A.; Khan, F.A.; Malik, S.; Khambaty, Y.

    2011-01-01

    Background: Thyroid enlargement is one of the common problems in patients presenting at outpatients department of ENT particularly in females. Thyroid nodules are common, thyroid cancer is uncommon and the most common way for it to present is as a solitary thyroid nodule. This study was conducted to evaluate the sensitivity and specificity of Fine Needle Aspiration Cytology (FNAC) in thyroid diseases. Method: This prospective analytic study was conducted at ENT Department of Karachi Medical and Dental College/Abbasi Shaheed Hospital during year 2004-8. One hundred and five cases were enrolled who underwent thyroid surgery after complete evaluation by history, clinical examination, Thyroid profile, Thyroid Scintigraphy, Ultrasound neck and FNAC. In cases which were revealed malignant by FNAC, CT scan were done to see the extent of disease and neck node status. Surgery was done in all cases and specimens sent for histopathology. Results: Male to female ratio of the patients was 1:8.5. Most common lesion was benign nodule (96). Malignant lesions were 9 in FNAC. In histopathology, the benign nodules were 92, and malignant cases were 13. Sensitivity of FNAC was 61.53% and specificity was 98.9%. Conclusion: FNAC in Thyroid has high sensitivity and specificity. (author)

  9. Ultrasound guided electrochemotherapy for the treatment of a clear cell thymoma in a cat

    Directory of Open Access Journals (Sweden)

    Enrico Pierluigi Spugnini

    2017-03-01

    Full Text Available A twelve-year-old male castrated domestic shorthair cat was presented for rapidly progressing respiratory distress. The cat was depressed, tachypneic and moderately responsive. Ultrasonography showed a mediastinal mass associated with a significant pleural effusion that needed tapping every five to seven days. Ultrasound guided biopsy yielded a diagnosis of clear cell thymoma upon histopathology. After complete staging procedures, the owner elected to treat the cat with electrochemotherapy (ECT using systemic bleomycin. Two sessions of ultrasound guided ECT were performed at two week intervals with trains of biphasic electric pulses applied using needle electrodes until complete coverage of the area was achieved. The treatment was well tolerated and resulted in partial remission (PR. Additional sessions were performed on a monthly basis. The cat is still in PR after fourteen months. ECT resulted in improved local control and should be considered among the available adjuvant treatments in pets carrying visceral tumors.

  10. MRI-guided vacuum-assisted breast biopsy: comparison with stereotactically guided and ultrasound-guided techniques

    Energy Technology Data Exchange (ETDEWEB)

    Imschweiler, Thomas; Freiwald, Bianka; Kubik-Huch, Rahel A. [Kantonspital Baden AG, Institute for Radiology, Baden (Switzerland); Haueisen, Harald [Kantonspital Aarau AG, Institute for Radiology, Aarau (Switzerland); Kampmann, Gert [Clinica Sant' Anna, Lugano, Sorengo (Switzerland); Rageth, Luzi [Adjumed Services AG, Zurich (Switzerland); Seifert, Burkhardt [Institute for Social and Preventive Medicine, University of Zurich, Division of Biostatistics, Zuerich (Switzerland); Rageth, Christoph [Breast Centre, Zurich (Switzerland)

    2014-01-15

    To analyse the development of MRI-guided vacuum-assisted biopsy (VAB) in Switzerland and to compare the procedure with stereotactically guided and ultrasound-guided VAB. We performed a retrospective analysis of VABs between 2009 and 2011. A total of 9,113 VABs were performed. Of these, 557 were MRI guided. MRI-guided VAB showed the highest growth rate (97 %) of all three procedures. The technical success rates for MRI-guided, stereotactically guided and ultrasound-guided VAB were 98.4 % (548/557), 99.1 % (5,904/5,960) and 99.6 % (2,585/2,596), respectively. There were no significant differences (P = 0.12) between the MRI-guided and the stereotactically guided procedures. The technical success rate for ultrasound-guided VAB was significantly higher than that for MRI-guided VAB (P < 0.001). There were no complications using MRI-guided VAB requiring open surgery. The malignancy diagnosis rate for MRI-guided VAB was similar to that for stereotactically guided VAB (P = 0.35). MRI-guided VAB is a safe and accurate procedure that provides insight into clinical breast findings. (orig.)

  11. Virtual reality, ultrasound-guided liver biopsy simulator: development and performance discrimination

    Science.gov (United States)

    Johnson, S J; Hunt, C M; Woolnough, H M; Crawshaw, M; Kilkenny, C; Gould, D A; England, A; Sinha, A; Villard, P F

    2012-01-01

    Objectives The aim of this article was to identify and prospectively investigate simulated ultrasound-guided targeted liver biopsy performance metrics as differentiators between levels of expertise in interventional radiology. Methods Task analysis produced detailed procedural step documentation allowing identification of critical procedure steps and performance metrics for use in a virtual reality ultrasound-guided targeted liver biopsy procedure. Consultant (n=14; male=11, female=3) and trainee (n=26; male=19, female=7) scores on the performance metrics were compared. Ethical approval was granted by the Liverpool Research Ethics Committee (UK). Independent t-tests and analysis of variance (ANOVA) investigated differences between groups. Results Independent t-tests revealed significant differences between trainees and consultants on three performance metrics: targeting, p=0.018, t=−2.487 (−2.040 to −0.207); probe usage time, p = 0.040, t=2.132 (11.064 to 427.983); mean needle length in beam, p=0.029, t=−2.272 (−0.028 to −0.002). ANOVA reported significant differences across years of experience (0–1, 1–2, 3+ years) on seven performance metrics: no-go area touched, p=0.012; targeting, p=0.025; length of session, p=0.024; probe usage time, p=0.025; total needle distance moved, p=0.038; number of skin contacts, p<0.001; total time in no-go area, p=0.008. More experienced participants consistently received better performance scores on all 19 performance metrics. Conclusion It is possible to measure and monitor performance using simulation, with performance metrics providing feedback on skill level and differentiating levels of expertise. However, a transfer of training study is required. PMID:21304005

  12. a pilot study of the diagnostic accuracy of fine needle aspirate cytol

    African Journals Online (AJOL)

    2018-06-02

    Jun 2, 2018 ... Fibroadenoma of the breast in a South African population -a pilot study of the ... Keywords: Fibroadenoma, diagnosis, breast ultrasonography, fine needle ..... breast cancer among Sudanese patients with breast palpa-.

  13. Models to teach lung sonopathology and ultrasound-guided thoracentesis

    Directory of Open Access Journals (Sweden)

    Jacek A. Wojtczak

    2014-12-01

    Full Text Available Lung sonography allows rapid diagnosis of lung emergencies such as pulmonary edema, hemothorax or pneumothorax. The ability to timely diagnose an intraoperative pneumothorax is an important skill for the anesthesiologist. However, lung ultrasound exams require an interpretation of not only real images but also complex acoustic artifacts such as A-lines and B-lines. Therefore, appropriate training to gain proficiency is important. Simulated environment using ultrasound phantom models allows controlled, supervised learning. We have developed hybrid models that combine dry or wet polyurethane foams, porcine rib cages and human hand simulating a rib cage. These models simulate fairly accurately pulmonary sonopathology and allow supervised teaching of lung sonography with the immediate feedback. In-vitro models can also facilitate learning of procedural skills, improving transducer and needle positioning and movement, rapid recognition of thoracic anatomy and hand – eye coordination skills. We described a new model to teach an ultrasound guided thoracentesis. This model consists of the experimenter’s hand placed on top of the water-filled container with a wet foam. Metacarpal bones of the human hand simulate a rib cage and a wet foam simulates a diseased lung immersed in the pleural fluid. Positive fluid flow offers users feedback when a simulated pleural effusion is accurately assessed.

  14. Individualized laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer.

    Science.gov (United States)

    Xu, Zhifeng; Yang, Zhangwei; Pan, Jianghua; Hu, Yiren

    2018-03-01

    Liver cancer is one of the most common malignancies of the digestive system. Minimally invasive ablation procedures have become one of the major means for treating unresectable multifocal liver cancer and have been extensively applied in primary and metastatic liver cancer treatment. Laparoscopic B-ultrasound-guided microwave ablation is an example of the progress made in this field. To analyze and summarize the results of and experience with laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer; moreover, the ablation effects were compared between tumors of different sizes. Laparoscope-guided needle ablation was conducted on 84 lesions from 32 patients with primary liver cancer based on tumor size, quantity, and location. Moreover, the perioperative data, ablation effects according to tumor size, and long-term follow-up results were analyzed. Among the 84 nodules treated via microwave ablation, tumors measuring ≤ 3 cm demonstrated complete ablation upon imaging analysis conducted 1 month after surgery. Moreover, 5 of the tumors measuring > 3 cm demonstrated incomplete ablation. In these cases, a second procedure was performed, until imaging studies confirmed that complete ablation was achieved. Laparoscopic microwave ablation allows for precise puncture positioning, an effective ablation range, and safe and feasible surgery, which is especially suitable for liver tumors located in sites difficult to access.

  15. Role of endoscopic ultrasound in diagnosis and management of hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    Koduru P

    2015-10-01

    Full Text Available Pramoda Koduru,1 Rei Suzuki,2 Sundeep Lakhtakia,3 Mohan Ramchandani,3 Dadang Makmun,4 Manoop S Bhutani,1 1Department of Gastroenterology, Hepatology and Nutrition, University of Texas MD Anderson Cancer Center, Houston, TX, USA; 2Department of Gastroenterology and Rheumatology, Fukushima University School of Medicine, Fukushima, Japan; 3Asian Institute of Gastroenterology, Hyderabad, India; 4University of Indonesia/Cipto Mangunkusumo Hospital, Jakarta, Indonesia Abstract: Hepatocellular carcinoma (HCC is an aggressive tumor and a leading cause of cancer-related deaths globally. The mortality rate remains high despite many advances in treatment. HCC is frequently diagnosed late in its course due to lack of classical symptoms at earlier stages. Endoscopic ultrasound (EUS has emerged as an important diagnostic tool for the diagnostic evaluation, staging, and treatment of gastrointestinal tract disorders. EUS-guided fine needle aspiration has been a valuable addition to EUS by being able to obtain tissue under direct visualization. Here, we review the potential role of EUS in the diagnosis and management of HCC. EUS seems to be a safe and reliable alternative method for obtaining tissue for diagnosis of liver cancer, especially for lesions that are inaccessible by traditional methods. EUS could play an important role in the diagnosis and management of HCC. Keywords: endoscopic ultrasound, fine needle aspiration, hepatocellular carcinoma, hepatoma

  16. Fine-needle cytology of breast lesions seen on mammograms

    International Nuclear Information System (INIS)

    Schmidt, R.A.; Ridlen, M.S.; Dowlatshahi, K.; Jokich, P.M.; Bibbo, M.

    1989-01-01

    Stereotactic fine-needle aspiration of nonpalpable breast lesions is operator dependent. The authors have analyzed 250 biopsies at our institution (comparing aspiration cytology with surgical biopsy) for sensitivity, false-negative, and insufficient-sample rates of three different interpreters. Needle aspiration as an alternative to biopsy or a follow-up for lesions of low mammographic suspicion would have resulted in detection of most, but not all, cancers. Over 40 additional biopsies would have been needed to detect each missed cancer. Eighty percent of surgical biopsies would have been needed to detect each missed cancer. Eighty percent of surgical biopsies for low-suspicion lesions could be avoided. Aspiration cytologic series should report separately insufficient samples and LCIS, and should use a consistent threshold for interpreting cytologic results

  17. The use of computerised tomography guided percutaneous fine needle aspiration in the evaluation of solitary pulmonary nodules.

    LENUS (Irish Health Repository)

    Khan, K A

    2012-02-01

    The evaluation of a solitary pulmonary nodule (SPN) has changed over the years with increased access to percutaneous computerised tomography (CT) guided fine needle aspiration (FNA), where bronchoscopy is unhelpful. The aim of our study was to evaluate the sample adequacy, diagnostic and complication rate of CT-FNA of a SPN at our academic teaching hospital over an 18 month period. CT-FNA was performed by a radiologist, with a cytopathologist in attendance to confirm the adequacy of the sample obtained. The size of the nodule, sample material and adequacy, diagnosis and complications were recorded. A total of 101 patients were included, 54 male and the mean age was 68 +\\/- 11 years. The mean size of the SPN was 2.3 cm (range 1-11 cm). 56 (56%) patients had a right SPN, 45 (45%) had a left SPN. CT-FNA was diagnostic in 80 (80%) patients and non-diagnostic in 21 (20%) patients. The sample was insufficient for immunocytochemistry, although the morphological appearance was diagnostic in 20 (25%) of the 80 patients. Pneumothorax occurred in 26\\/101 (26%) patients post CT-FNA, of these 7 (27%) required chest drain insertion, while 19 (73%) were managed conservatively. CT FNA is a useful tool for the diagnosis of a SPN, with our diagnostic accuracy comparable to that reported in the literature. However, CT-FNA may not provide adequate sample volume to perform ancillary testing and has a moderate complication rate.

  18. Comparison of specimen adequacy in fine needle aspiration cytology performed with different gauge needles in palpable external swellings

    International Nuclear Information System (INIS)

    Sarfraz, T.; Bashir, S.; Tariq, H.; Malik, T.M.

    2013-01-01

    Background: Fine Needle Aspiration Cytology (FNAC) of external swellings may yield different specimen adequacy depending on different gauge needles used for aspiration. Objective: To compare the specimen adequacy aspirated by various gauge (21 and 22) needles in external palpable swellings of lymph nodes, thyroid gland, salivary glands, breast and soft tissue. Study Design: Comparative cross sectional study. Duration: Six months (1st Jan 2012 to 30th June 2012). Setting: Histopathology/Cytology department Combined Military Hospital Peshawar (Pakistan). Methodology: This was a prospective study of 200 cases in which FNAC was performed with either 21 or 22 gauge needles (100 cases with 21 gauge and 100 with 22 gauge needles). Equal number of aspirations were done with 21 and 22 gauge needles from the swellings of thyroid gland, lymph nodes, salivary glands, breast and soft tissue. Results were analyzed for specimen adequacy by using SPSS 17. Results: A total number of 200 cases were recruited in this study, out of which 100 were aspirated with 21 gauge needles and 100 with 22 gauge needles. Specimen adequacy in swellings of thyroid, lymph nodes and salivary glands was better with 22 gauge amounting 90%, 80% and 80% respectively, as compared to yield with 21 gauge needles which was 85%, 70% and 60% respectively. On the other hand in swellings of breast and soft tissue, the specimen adequacy was better with 21 gauge needles giving 98% and 90 % adequate yield respectively as compared to 22 gauge needles which was 70% and 40 % respectively. Conclusion: Needles of smaller gauge (22 gauge) give a better yield in swellings of thyroid, lymph nodes and salivary gland while in swellings of breast and soft tissue sample adequacy is better with larger gauge needle (21 gauge). (author)

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... can be guided by ultrasound, are used to sample cells from organs for laboratory testing help detect ... biopsies, in which needles are used to extract sample cells from an abnormal area for laboratory testing. ...

  20. A novel method for accurate needle-tip identification in trans-rectal ultrasound-based high-dose-rate prostate brachytherapy.

    Science.gov (United States)

    Zheng, Dandan; Todor, Dorin A

    2011-01-01

    In real-time trans-rectal ultrasound (TRUS)-based high-dose-rate prostate brachytherapy, the accurate identification of needle-tip position is critical for treatment planning and delivery. Currently, needle-tip identification on ultrasound images can be subject to large uncertainty and errors because of ultrasound image quality and imaging artifacts. To address this problem, we developed a method based on physical measurements with simple and practical implementation to improve the accuracy and robustness of needle-tip identification. Our method uses measurements of the residual needle length and an off-line pre-established coordinate transformation factor, to calculate the needle-tip position on the TRUS images. The transformation factor was established through a one-time systematic set of measurements of the probe and template holder positions, applicable to all patients. To compare the accuracy and robustness of the proposed method and the conventional method (ultrasound detection), based on the gold-standard X-ray fluoroscopy, extensive measurements were conducted in water and gel phantoms. In water phantom, our method showed an average tip-detection accuracy of 0.7 mm compared with 1.6 mm of the conventional method. In gel phantom (more realistic and tissue-like), our method maintained its level of accuracy while the uncertainty of the conventional method was 3.4mm on average with maximum values of over 10mm because of imaging artifacts. A novel method based on simple physical measurements was developed to accurately detect the needle-tip position for TRUS-based high-dose-rate prostate brachytherapy. The method demonstrated much improved accuracy and robustness over the conventional method. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  1. [Percutaneous ultrasound-guided drainage in the surgical treatment of acute severe pancreatitis].

    Science.gov (United States)

    Delattre, J-F; Levy Chazal, N; Lubrano, D; Flament, J-B

    2004-11-01

    To report results of percutaneous ultrasound-guided drainage, performed by a surgeon, in the treatment of complications of acute pancreatitis (AP), and to determine the role of this technique in the therapeutic armamentarium of severe AP. From 1986 to 2001, 59 patients were included in this retrospective study. All patients initially had severe necrotizing AP (mean Ranson score = 4.1 ; range : 2-7). Anatomical lesions included pancreatic abscess in 6 patients and necrosis in 53 (17 stage D and 36 stage E according to Balthazar's classification). Necrosis was infected in 42 and sterile in 11 respectively. Drainage was performed under ultrasound guidance and local anaesthesia using small-diameter drains (7-14 French). Drainage was performed on average 23 days after onset of AP. Infection was proven by fine-needle aspiration in 47 (80 %) patients (41 infected necrosis and 6 localized abscess). In one patient, culture of aspirated fluid was negative but necrosis was infected (one false negative). Culture of aspirated fluid was negative and necrosis was sterile in 11 patients. Nineteen (32%) patients healed without subsequent surgery: 7 (16%) in the infected necrosis group, 6(55%) in the sterile necrosis group, and 6 (100%) in the abscess group. Forty (68%) patients had subsequent necrosectomy including 8 (14%) who died. Twenty (34 %) digestive fistulas healed spontaneously, except one treated by diversion stomia. Of the 16 (27 %) pancreatic fistulas, 6 needed subsequent interventional treatment. In selected patients, percutaneous drainage can represent an alternative to surgery with a 14% mortality rate. The high rate of subsequent necrosectomy suggests that drains with larger diameter, possibly associated with continuous irrigation, should be used.

  2. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach

    Directory of Open Access Journals (Sweden)

    Feng Mao

    2017-01-01

    Full Text Available Aim. To investigate the value of contrast-enhanced ultrasound (CEUS guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6 who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US guidance group (n=75. All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3% and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm nonenhanced necrotic areas. More inner (20.0% versus 6.7% and surrounding (18.3% versus 2.7% major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%. The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%. Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  3. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach.

    Science.gov (United States)

    Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping

    2017-01-01

    Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  4. Fine needle aspiration cytology versus frozen section in branchial cleft cysts.

    Science.gov (United States)

    Begbie, F; Visvanathan, V; Clark, L J

    2015-02-01

    Branchial cleft cysts occur because of a failure of involution of the second branchial cleft. However, as well-differentiated squamous cell carcinoma can mimic branchial cleft cysts, there is a lack of consensus on the appropriate management of cystic neck lumps. To report our experience of fine needle aspiration cytology and frozen section examination in the management of cystic neck lumps. Retrospective case note review of patients managed in the Southern General Hospital, Scotland, UK. The sensitivity of fine needle aspiration cytology and frozen section for detecting branchial cleft cysts was 75 per cent and 100 per cent respectively. Two patients who did not undergo intra-operative frozen section examination were either over- or under-treated, which is discussed. Adult patients subjected to surgical excision of a suspected branchial cyst should undergo intra-operative frozen section analysis regardless of clinical suspicion for malignancy. This part of management is critical to ensure patients are offered appropriate treatment.

  5. Role of [18F]fluorodeoxyglucose positron emission tomography-computed tomography, sonography, and sonographically guided fine-needle aspiration biopsy in the diagnosis of axillary lymph nodes in patients with breast cancer: comparison of diagnostic performance.

    Science.gov (United States)

    Sohn, Yu-Mee; Hong, Il Ki; Han, Kyunghwa

    2014-06-01

    The aim of this study was to compare the diagnostic performance of [(18)F]fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) with that of sonography and sonographically guided fine-needle aspiration (FNA) for determining the preoperative axillary lymph node (ALN) status and to evaluate the factors related to false-negative PET-CT, sonographic, and FNA results in ALN staging of invasive ductal carcinoma. From March 2009 to July 2012, 226 patients had a diagnosis of primary breast cancer. Among these patients, 107 constituted the study population after exclusion of transferred patients and patients with breast cancer other than invasive ductal carcinoma. The diagnostic performance of the modalities was compared with pathologic reports. Univariate and multivariate analyses were used to evaluate the relationship between clinicopathologic factors (symptoms, T stage, hormone receptors, and histologic grade), false-negative results, and true-negative results on PET-CT, sonography, and FNA. Of the 107 patients, 45 (42.1%) had positive results on final pathologic analysis of ALNs. Sonographically guided FNA had a significantly higher specificity, positive predictive value, accuracy, and area under the receiver operating characteristic curve than sonography and PET-CT (P < .01). When sonography and PET-CT were combined, the sensitivity was significantly improved (P = .019) compared with sonography alone. When FNA and PET-CT were combined, the sensitivity and negative predictive value were significantly increased compared with each modality (P < .01). Sonographically guided FNA was found to be an excellent diagnostic tool for preoperative evaluation of the ALN status. To obviate the step of sentinel lymph node biopsy for determining the ALN status, combined evaluation of ALNs by these modalities may be more complementary than the use of a single modality. © 2014 by the American Institute of Ultrasound in Medicine.

  6. Quantitative analysis of fine needle aspiration biopsy samples

    International Nuclear Information System (INIS)

    Rajer, M.; Kmet, M.

    2005-01-01

    Background. The fine needle aspiration biopsy (FNAB) is one of the methods used in tumour evaluation. Since a certain number of tumour cells are needed for a complete diagnostic algorithm, we wanted to test how many cells remain in the needle and syringe after routine stains have been made and which factors influence this number. The remaining cells are used in ancillary diagnostic procedures. Materials and methods. One hundred fifty two FNAB samples of tumours of the breast, thyroid and lymph nodes were included in our study. We counted the cells which were left in the needle and the syringe after the standard smears had been made. Buerker-Tuerk's chamber was used for this purpose. Results. The number of cells depended on the organ from which the cells had been aspirated, on the type of tumour and, in the case of breast cancer, also on the level of experience of the FNAB performer. The percentage of samples with too few cells for all modern diagnostic methods (<5x105 ) is lowest in FNAB of lymph nodes (4.9%), followed by breast (16.7%) and thyroid (18%). Conclusions. We concluded that FNAB in the majority of cases grants a sufficient number of cells for the standard microscopic evaluation and also ancillary diagnostic procedures. (author)

  7. Advances in the Management of Upper Gastrointestinal Subepithelial Tumor: Pathologic Diagnosis Using Endoscopy without Endoscopic Ultrasound-Guided Biopsy

    Directory of Open Access Journals (Sweden)

    Hang Lak Lee

    2016-05-01

    Full Text Available Until now, biopsy methods for subepithelial tumors (SETs have focused on endoscopic ultrasound (EUS-guided biopsy; however, these methods have several limitations. We devised a simple method for pathologic diagnosis of SETs. SETs are occasionally diagnosed during endoscopy, and lesions are generally small and asymptomatic. It can be challenging to decide on a management plan for large asymptomatic SETs. EUS imaging provides information regarding the size, layer, and echo pattern of the lesions. Patient management plans have traditionally been determined based on EUS images, whereby the endoscopist chooses to either monitor or remove the tumor. However, EUS alone cannot diagnose and evaluate upper gastrointestinal SETs with high accuracy. As sufficient tissue samples are required for the accurate diagnosis of SETs, EUS-guided biopsy techniques such as EUS fine-needle aspiration and trucut biopsy are currently used. However, these methods have a relatively low diagnostic accuracy and do not always provide information upon immunohistochemical staining. Endoscopists can easily detect a submucosal mass after creating an iatrogenic mucosal ulcer, after which tissue sampling is performed by using endoscopic biopsy. Furthermore, pathologic results can differentiate between benign and premalignant lesions. Here, we introduce a simple method for the pathologic diagnosis of SETs.

  8. MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach

    International Nuclear Information System (INIS)

    Rossi, Umberto G.; Seitun, Sara; Ferro, Carlo

    2011-01-01

    The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.

  9. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  10. [Cost analysis of ultrasound-guided transrectal needle biopsy in prostatic carcinoma].

    Science.gov (United States)

    Bissoli, E; Fandella, A; La Torre, E; Faggiano, L; Anselmo, G; Frasson, F

    1998-04-01

    The literature mortality and morbidity rates from prostatic carcinoma prompt to the better use of some routine diagnostic tools such as transrectal ultrasound-guided biopsy. We evaluated the overall cost of transrectal ultrasound biopsy (TRUSB) of the prostate and investigated the economic impact of the procedures currently used to diagnose prostatic carcinoma. The total cost of TRUSB was calculated with reference to 247 procedures performed in 1996. The following cost factors were evaluated: personnel, materials, maintenance-equipment depreciation, energy consumption and hospital overheads. A literature review was also carried out to check if our extrapolated costs corresponded to those of other authors worldwide and to consider them in the wider framework of the cost effectiveness of the strategies for the early diagnosis of prostatic cancer. The overall cost of TRUSB was Itl. 249,000, obtained by adding together the costs of: personnel (Itl. 160,000); materials (Itl. 59,000); equipment maintenance and depreciation (Itl. 12,400); energy consumption (Itl. 100); hospital overheads (Itl. 17,500). The literature review points out TRUSB as a clinically invasive tool for diagnosing prostatic carcinoma whose cost-effectiveness is debated. Cadaver studies report the presence of cancer cells in the prostate of 50% of 70-year-old men, while extrapolations calculate a morbidity from prostatic carcinoma in 9.5% of 50-year-old men. It is therefore obvious that randomized prostatic biopsies, methods apart, are very likely to be positive. This probability varies with the patient's age, the level of prostate specific antigen (PSA), the density of PSA/cm3 of prostate volume (PSAD), and the positivity of exploration and/or transrectal ultrasound findings. Despite the strict application of all these criteria and the critical assessment of the patient's general conditions, TRUSB is indicated for 16% of the male population over 50, with obvious implications. It has been recently

  11. Implante subcutáneo de un carcinoma hepatocelular tras la punción aspiración con aguja fina Subcutaneous seeding of hepatocellular carcinoma after fine-needle percutaneous biopsy

    Directory of Open Access Journals (Sweden)

    D. Martínez Ramos

    2007-06-01

    Full Text Available Los implantes subcutáneos son una complicación rara tras la punción aspiración con aguja fina de los carcinomas hepatocelulares. Los autores describen un caso de implante subcutáneo neoplásico en una mujer de 70 años con cirrosis hepática por virus C complicada con un carcinoma hepatocelular. Se efectuó una punción aspiración con aguja fina en el segmento II hepático. El implante tumoral se desarrolló en el trayecto de la punción aspiración. La tumoración subcutánea fue extirpada quirúrgicamente y el estudio anatomopatológico confirmó que se trataba de un carcinoma hepatocelular bien diferenciado.Subcutaneous tumor seeding after fine-needle percutaneous biopsy for hepatocellular carcinoma is a rarely seen complication. The authors describe a case of subcutaneous neoplastic seeding in a 70-year-old woman with chronic hepatitis C virus complicated by hepatocellular carcinoma. Ultrasonically guided fine-needle aspiration biopsy was performed in segment II of the liver. The neoplastic seeding developed along the needle track used to carry out the fine-needle biopsy. The subcutaneous tumor was excised, and histological examination revealed a well-differentiated hepatocellular carcinoma.

  12. Ultrasound-guided antegrade access during laparoscopic pyeloplasty in infants less than one year of age: A point of technique

    Directory of Open Access Journals (Sweden)

    Arvind Ganpule

    2012-01-01

    Full Text Available Background: Access to urethras and ureters of infants may be hazardous and injurious through an endoscopic route. Placement and removal of stents in infants requires anaesthesia and access through these small caliber urethras. We describe our technique of placing antegrade splint during a laparoscopic pyeloplasty in these infants. Materials and Methods: An ultrasound-guided percutaneous renal access is obtained. Telescopic metal two part needle is passed into the kidney over a guide wire. A second guide wire is passed through the telescopic metal two part needle. The tract is dilated with 14 Fr screw dilator. Over one guide wire, a 5 Fr ureteric catheter is passed and coiled in the renal pelvis. Over the other wire, a 14 Fr malecot catheter is placed as nephrostomy. Laparoscopic pyeloplasty is then done. During pyelotomy, the ureteric catheter is pulled and advanced through the ureter before the pyeloplasty is completed. The ureteric catheter thus acts as a splint across the anastomosis. Ureteric catheter is removed on the 3 rd post operative day and nephrostomy is clamped. Nephrostomy is removed on 4 th post operative day if child is asymptomatic. The modified technique was successfully done in five patients aged less than one year old. All patients tolerated the procedure well. Post operative period was uneventful in all. Conclusion: Ultrasound-guided ante grade nephroureteral ureteral splint for infant laparoscopic pyeloplasty is safe. It avoids the need for urethral instrumentation for insertion and removal of stents in these small patients.

  13. Treatment of the calcific tendinopathy of the rotator cuff by ultrasound-guided percutaneous needle lavage. Two years prospective study

    Science.gov (United States)

    Castillo-González, Federico Del; Ramos-Álvarez, Juan José; Rodríguez-Fabián, Guillermo; González-Pérez, José; Calderón-Montero, Javier

    2014-01-01

    Summary Background: to evaluate the short and long term effectiveness of ultrasonography (US)-guided percutaneous needle lavage in calcific tendinopathy of the rotator cuff. To study the evolution of the size of calcifications and pain in the two years after treatment. Methods: study design: A 2 year longitudinal prospective study is carried out after applying the UGPL technique on a number of patients diagnosed with calcific tendinitis of the rotator cuff. Clinical, ultrasound and radiology follow-up controls were performed, 3 months, 6 months, one year and two years after the treatment. The Visual Analog Scale (VAS) was used to assess the pain. The degree and point of pain is selected on a 10 cm line, arranged horizontally or vertically. The “0” represents no pain and “10” represents worst pain. The population studied was made up of 121 patients that required our service as a result of suffering from a painful shoulder. Results: the pain (VAS) and the size of the calcification significantly decreased with the application of the technique (ptendinitis of the shoulder. The intervention is simple, cost-effective, does not require hospitalization, involves no complications, rehabilitation treatment is not required and it shows very few side effects without sequelae, significantly reducing the size of the calcification and pain in the majority of patients. PMID:25332939

  14. Ultrasound-Guided Regional Anesthesia for Procedures of the Upper Extremity

    Directory of Open Access Journals (Sweden)

    Farheen Mirza

    2011-01-01

    Full Text Available Anesthesia options for upper extremity surgery include general and regional anesthesia. Brachial plexus blockade has several advantages including decreased hemodynamic instability, avoidance of airway instrumentation, and intra-, as well as post-operative analgesia. Prior to the availability of ultrasound the risks of complications and failure of regional anesthesia made general anesthesia a more desirable option for anesthesiologists inexperienced in the practice of regional anesthesia. Ultrasonography has revolutionized the practice of regional anesthesia. By visualizing needle entry throughout the procedure, the relationship between the anatomical structures and the needle can reduce the incidence of complications. In addition, direct visualization of the spread of local anesthesia around the nerves provides instant feedback regarding the likely success of the block. This review article outlines how ultrasound has improved the safety and success of brachial plexus blocks. The advantages that ultrasound guidance provides are only as good as the experience of the anesthesiologist performing the block. For example, in experienced hands, with real time needle visualization, a supraclavicular brachial plexus block has changed from an approach with the highest risk of pneumothorax to a block with minimal risks making it the ideal choice for most upper extremity surgeries.

  15. Ultrasound-guided approach for axillary brachial plexus, femoral nerve, and sciatic nerve blocks in dogs.

    Science.gov (United States)

    Campoy, Luis; Bezuidenhout, Abraham J; Gleed, Robin D; Martin-Flores, Manuel; Raw, Robert M; Santare, Carrie L; Jay, Ariane R; Wang, Annie L

    2010-03-01

    To describe an ultrasound-guided technique and the anatomical basis for three clinically useful nerve blocks in dogs. Prospective experimental trial. Four hound-cross dogs aged 2 +/- 0 years (mean +/- SD) weighing 30 +/- 5 kg and four Beagles aged 2 +/- 0 years and weighing 8.5 +/- 0.5 kg. Axillary brachial plexus, femoral, and sciatic combined ultrasound/electrolocation-guided nerve blocks were performed sequentially and bilaterally using a lidocaine solution mixed with methylene blue. Sciatic nerve blocks were not performed in the hounds. After the blocks, the dogs were euthanatized and each relevant site dissected. Axillary brachial plexus block Landmark blood vessels and the roots of the brachial plexus were identified by ultrasound in all eight dogs. Anatomical examination confirmed the relationship between the four ventral nerve roots (C6, C7, C8, and T1) and the axillary vessels. Three roots (C7, C8, and T1) were adequately stained bilaterally in all dogs. Femoral nerve block Landmark blood vessels (femoral artery and femoral vein), the femoral and saphenous nerves and the medial portion of the rectus femoris muscle were identified by ultrasound in all dogs. Anatomical examination confirmed the relationship between the femoral vessels, femoral nerve, and the rectus femoris muscle. The femoral nerves were adequately stained bilaterally in all dogs. Sciatic nerve block. Ultrasound landmarks (semimembranosus muscle, the fascia of the biceps femoris muscle and the sciatic nerve) could be identified in all of the dogs. In the four Beagles, anatomical examination confirmed the relationship between the biceps femoris muscle, the semimembranosus muscle, and the sciatic nerve. In the Beagles, all but one of the sciatic nerves were stained adequately. Ultrasound-guided needle insertion is an accurate method for depositing local anesthetic for axillary brachial plexus, femoral, and sciatic nerve blocks.

  16. Current status of core needle biopsy of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Thyroid nodules are a common clinical problem. Fine-needle aspiration (FNA) and large-needle biopsy have been used to diagnose thyroid nodules. Before the 1980s, large-needle biopsy was the standard procedure for the thyroid, but FNA became the standard diagnostic tool in the 1980s because it is a safe procedure that leads to accurate diagnoses. With advances in core needle biopsy (CNB) devices (i.e., spring-activated core needles) and development of high-resolution ultrasound, it has become possible to make accurate diagnoses while minimizing complications. Although 18- to 21-gauge core needles can be used to biopsy thyroid nodules, 18-gauge needles are most commonly used in Korea. The relationships among the size of the needle, the number of core specimens, and diagnostic accuracy have not yet been conclusively established, but the general tendency is that thinner needles cause less damage to the normal thyroid, but allow a smaller amount of thyroid tissue to be biopsied to be obtained. These relationships may be validated in the future.

  17. Ultrasound-controlled neuronavigator-guided brain surgery.

    Science.gov (United States)

    Koivukangas, J; Louhisalmi, Y; Alakuijala, J; Oikarinen, J

    1993-07-01

    The development of a unique neurosurgical navigator is described and a preliminary series of seven cases of intracerebral lesions approached with the assistance of this neuronavigation system under ultrasound control is presented. The clinical series included five low-grade astrocytomas, one chronic intracerebral hematoma, and one porencephalic cyst. Management procedures included biopsy in all cases, drainage of the hematoma, and endoscopy and fenestration for the cyst. The features of the neuronavigation system are interactive reconstructions of preoperative computerized tomography and magnetic resonance imaging data, corresponding intraoperative ultrasound images, versatility of the interchangeable end-effector instruments, graphic presentation of instruments on the reconstructed images, and voice control of the system. The principle of a common axis in the reconstructed images served to align the navigational pointer, biopsy guide, endoscope guide, ultrasound transducer, and surgical microscope to the brain anatomy. Intraoperative ultrasound imaging helped to verify the accuracy of the neuronavigator and check the results of the procedures. The arm of the neuronavigation system served as a holder for instruments, such as the biopsy guide, endoscope guide, and ultrasound transducer, in addition to functioning as a navigational pointer. Also, the surgical microscope was aligned with the neuronavigator for inspection and biopsy of the hematoma capsule to rule out tumor etiology. Voice control freed the neurosurgeon from manual exercises during start-up and calibration of the system.

  18. Transesophageal Ultrasonography for Lung Cancer Staging

    DEFF Research Database (Denmark)

    Konge, Lars; Annema, Jouke; Vilmann, Peter

    2013-01-01

    Accurate mediastinal nodal staging is essential for patients with resectable non-small-cell lung cancer and is achieved by combined endobronchial ultrasound and transesophageal endoscopic ultrasound (EUS). Training requirements for EUS-guided fine-needle aspiration (FNA) for lung cancer staging...

  19. Ultrasound techniques in the evaluation of the mediastinum, part 2

    DEFF Research Database (Denmark)

    Jenssen, Christian; Annema, Jouke Tabe; Clementsen, Paul

    2015-01-01

    and inoperable lung cancer (e.g., surgery vs. combined chemoradiation therapy). Tissue sampling is often indicated for accurate nodal staging. Recent international lung cancer staging guidelines clearly state that endosonography should be the initial tissue sampling test over surgical staging. Mediastinal nodes...... can be sampled from the airways [endobronchial ultrasound combined with transbronchial needle aspiration (EBUS-TBNA)] or the esophagus [endoscopic ultrasound fine needle aspiration (EUS-FNA)]. EBUS and EUS have a complementary diagnostic yield and in combination virtually all MLNs can be biopsied...... and mediastinal staging of lung cancer. A specific emphasis will be on learning mediastinal endosonography. Part 1 deals with an introduction into ultrasound techniques, MLN anatomy and diagnostic reach of ultrasound techniques and part 2 with the clinical work up of neoplastic and inflammatory mediastinal...

  20. Annals of African Medicine - Vol 10, No 2 (2011)

    African Journals Online (AJOL)

    Secondhand smoke exposure among non smoking adults in two Nigerian cities · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT ... Ultrasound guided percutaneous fine needle aspiration biopsy/automated needle core biopsy of abdominal lesions: Effect on management and cost effectiveness · EMAIL FREE FULL ...

  1. Ultrasound-guided image fusion with computed tomography and magnetic resonance imaging. Clinical utility for imaging and interventional diagnostics of hepatic lesions; Ultraschallgestuetzte Bildfusion mittels CT und MRT. Klinische Bedeutung fuer die bildgebende und interventionelle Diagnostik von Leberlaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Clevert, D.A.; Helck, A.; Paprottka, P.M.; Trumm, C.; Reiser, M.F. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Zengel, P. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Grosshadern, Klinik fuer Hals-, Nasen- und Ohrenheilkunde, Muenchen (Germany)

    2012-01-15

    Abdominal ultrasound is often the first-line imaging modality for assessing focal liver lesions. Due to various new ultrasound techniques, such as image fusion, global positioning system (GPS) tracking and needle tracking guided biopsy, abdominal ultrasound now has great potential regarding detection, characterization and treatment of focal liver lesions. Furthermore, these new techniques will help to improve the clinical management of patients before and during interventional procedures. This article presents the principle and clinical impact of recently developed techniques in the field of ultrasound, e.g. image fusion, GPS tracking and needle tracking guided biopsy and discusses the results based on a feasibility study on 20 patients with focal hepatic lesions. (orig.) [German] Bei der Bildfusion von Ultraschall mit anderen schnittbildgebenden Verfahren (CT, MRT) handelt es sich um ein relativ neuartiges Verfahren, welches unter Studienbedingungen jedoch bereits erfolgreich eingesetzt wurde. In der folgenden Machbarkeitsstudie soll der Nutzen weiterfuehrender Anwendungen der sonographischen Bildfusion, dem so genannten Global-Positioning-System- (GPS-) und Needle-Tracking, untersucht werden. Dabei handelt es sich um Instrumente, die insbesondere die Diagnostik und das Staging (GPS-Tracking) bzw. die bioptische Abklaerung (Needle-Tracking) von Patienten mit fokalen Leberlaesionen erleichtern. In diesem Artikel werden das Prinzip und die Anwendungsmoeglichkeiten dieser neuen Techniken anhand konkreter Beispiele in einem Kollektiv von 20 Patienten mit fokalen Leberlaesionen vorgestellt und erlaeutert. (orig.)

  2. Stereotaxic Fine-Needle Aspiration Cytologic Evaluation of Non-palpable Breast Lesions

    Directory of Open Access Journals (Sweden)

    M Haghighi

    2005-07-01

    Full Text Available Background: Although long-term mammography is the standard means of evaluation for the probably benign lesions of breast, some times we feel obliged to know about the benignity and the extent of lesions earlier. Therefore we evaluated the diagnostic value of stereotaxic fine-needle aspiration (SFNA in low suspicion breast lesions as an alternative to the routine modality. Methods: The study included 150 low-suspicion or probably benign breast lesions detected on mammography. All cases underwent SFNA and followed by exciosional biopsy or follow-up mammography based on SFNA findings. Results: Fibroadenoma and normal tissue lesions were diagnosed in 57% of patients, in whom no evidence of malignancy was found in the follow-up period. In 48 patients with cytologic findings suggestive of proliferative fibrocystic disease, three cases of malignancy were detected by excisional biopsy. Conclusion: A SFNA result suggesting benignity allows safe clinical follow-up, whereas a suspicious or equivocal diagnosis needs more invasive modalities for further investigations. Key words: Breast, Mammography, Stereotaxic, Fine-Needle Aspiration (FNA

  3. Transperineal seed-implantation guided by biplanar transrectal ultrasound

    DEFF Research Database (Denmark)

    Holm, Hans Henrik; Torp-Pedersen, S; Myschetzky, P

    1990-01-01

    A new method for precise transperineal placement of therapeutic sources in prostatic cancer is described. The method is a modification of the technique described in 1983 by Holm and coworkers. Insertion of needles is monitored by transverse as well as longitudinal transrectal ultrasound....

  4. Transperineal seed-implantation guided by biplanar transrectal ultrasound

    International Nuclear Information System (INIS)

    Holm, H.H.; Torp-Pedersen, S.; Myschetzky, P.

    1990-01-01

    A new method for precise transperineal placement of therapeutic sources in prostatic cancer is described. The method is a modification of the technique described in 1983 by Holm and coworkers. Insertion of needles is monitored by transverse as well as longitudinal transrectal ultrasound

  5. Guide for the realization of core needle biopsy through stereotaxy in the diagnosis of suspicious breast lesions of malignity

    International Nuclear Information System (INIS)

    Jimenez Zuniga, Jorge Luis

    2012-01-01

    demonstrated to be more precise and to make more accurate the diagnostic evaluation. While, the systems of vacuum-assisted biopsy have allowed the obtention of higher quality cylinders, clearly improving results, especially in cases of microcalcifications. The main indications for the use of stereotaxy in the intervention of the breast are analyzed, among which can be mentioned: fine-needle aspiration biopsy, core needle biopsy and preoperative localization. The technique of fine-needle aspiration biopsy has gained acceptation in the diagnosis of palpable lesions of the breast, the function of this technique in the management of nonpalpable lesions not is completely defined, due to the high percentage of insufficient samples. The systems of core needle biopsy have allowed the obtention of multiple cylinders with great diagnostic reliability, especially in the case of breast nodules. However, its use in microcalcifications has showed false negative results. The preoperative localization through needle in the nonpalpable lesions of the breast, has allowed to the radiologist to provide a guide to the surgeon that has realized the open biopsy, ensuring thus, that surgical procedure can be carried out quickly and with the best possible cosmetic result. The radiological assessment of the breast lesions in mammography are defined, in order to standardize the terminology applied at the time to report studies of the breast, to categorize the lesions according to the level of suspicion and to assign a recommendation to follow in injury determined. Before all nonpalpable breast lesion that has required a biopsy, should be considered first which will be the guidance system most adequate, and second, which is the technique with best diagnostic performing and better relationship cost/effectiveness. The core needle biopsy (CNB) has been a little aggressive technique and highly reliable in the diagnosis of the palpable and nonpalpable lesions. The sensitivity of the CNB has been different

  6. Pancreatic Tuberculosis or Autoimmune Pancreatitis

    Directory of Open Access Journals (Sweden)

    Ayesha Salahuddin

    2014-01-01

    Full Text Available Introduction. Isolated pancreatic and peripancreatic tuberculosis is a challenging diagnosis due to its rarity and variable presentation. Pancreatic tuberculosis can mimic pancreatic carcinoma. Similarly, autoimmune pancreatitis can appear as a focal lesion resembling pancreatic malignancy. Endoscopic ultrasound-guided fine needle aspiration provides an effective tool for differentiating between benign and malignant pancreatic lesions. The immune processes involved in immunoglobulin G4 related systemic diseases and tuberculosis appear to have some similarities. Case Report. We report a case of a 59-year-old Southeast Asian male who presented with fever, weight loss, and obstructive jaundice. CT scan revealed pancreatic mass and enlarged peripancreatic lymph nodes. Endoscopic ultrasound-guided fine needle aspiration confirmed the presence of mycobacterium tuberculosis. Patient also had high immunoglobulin G4 levels suggestive of autoimmune pancreatitis. He was started on antituberculosis medications and steroids. Clinically, he responded to treatment. Follow-up imaging showed findings suggestive of chronic pancreatitis. Discussion. Pancreatic tuberculosis and autoimmune pancreatitis can mimic pancreatic malignancy. Accurate diagnosis is imperative as unnecessary surgical intervention can be avoided. Endoscopic ultrasound-guided fine needle aspiration seems to be the diagnostic test of choice for pancreatic masses. Long-term follow-up is warranted in cases of chronic pancreatitis.

  7. Selective fine needle aspiration of parotid masses. FNA should be performed in all patients older than 60 years.

    LENUS (Irish Health Repository)

    Kieran, S M

    2012-02-01

    OBJECTIVES: The exact role of fine needle aspiration in the pre-operative assessment of patients presenting with parotid masses is controversial. Some surgeons propose that fine needle aspiration be performed only selectively in those patients with likely malignant disease, whilst others recommend it for all patients presenting with such a mass. Intuitively, one would expect older patients to be more likely to suffer from primary malignant parotid tumours and secondary deposits of malignant skin tumours. Therefore, we hypothesised that older patients with a parotid mass should undergo fine needle aspiration regardless of their medical history. DESIGN: We retrospectively reviewed 197 consecutive parotidectomies to test this hypothesis. RESULTS: One hundred and twenty-one patients (61.4 per cent) were diagnosed with benign disease, whilst 76 (38.6 per cent) were diagnosed with malignant disease. Eighty-three per cent of patients aged 60 years or younger had benign disease, as opposed to 35.6 per cent of patients aged more than 60 years. Malignant disease occurred more commonly in patients older than 60 years (odds ratio 8.962, 95 per cent confidence interval 4.607-17.434). CONCLUSION: In patients with a parotid mass, fine needle aspiration should be performed on all those aged 60 years or older.

  8. Diagnose of the prostate cancer: Utility of the antigen specifies of prostate, transrectal echography and aspired by fine needle; Diagnostico del cancer de prostata: utilidad del antigeno especifico de prostata, ecografia transrectal y aspirado por aguja fina

    Energy Technology Data Exchange (ETDEWEB)

    De Nubbila, Eduardo; Rosillo, Marco; Fals, Orlando

    1993-04-01

    We describe three improved methods of detecting prostate cancer while it is still confined to the gland: Prostrate specific antigen (PSA), trans-rectal ultrasound (TRUS) and trans-rectal ultrasound-directed prostatic fine needle aspirate (TRFNA). Of a total of 60 studied cases, 23 cytological procedures were done, and half of these were found to have prostate cancer. We compare traditional methods like digital rectal examination and prostatic phosphatase acid with PSA and TRFNA. We conclude that these methods increase the sensibility and specificity of early prostate cancer detection.

  9. Evaluation of a mammographic stereotactic device for localization, fine-needle aspiration cytologic studies, and core biopsy of suspicious lesions

    International Nuclear Information System (INIS)

    Fajardo, L.J.; Davey, G.A.

    1988-01-01

    Mammography-guided interventional breast procedures, such as preoperative localization, fine-needle aspiration cytology (FNAC), and core biopsy of suspicious lesions, require accurate three-dimensional localization. The authors have evaluated a prototype stereotactic mammography device for localizing abnormalities with both phantom and clinical studies. Twenty-six localizations on a phantom were within 0.5 mm +- 0.93 (standard deviation) from the lesions; accuracy in clinical procedures was within 0.6 mm +- 0.8. Procedures are performed an average of 8 minutes faster with this device. They are prospectively evaluating mammography-guided FNAC and core biopsy of suspicious lesions in 100 patients. Results of FNAC performed without the stereotactic device agreed with results of open surgical biopsy in six of eight patients; results of core biopsy agreed in seven of eight

  10. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    Science.gov (United States)

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  11. [Results of endobronchial ultrasound-guided transbronchial needle aspiration in lung cancer: importance of the lymph node involvement prevalence].

    Science.gov (United States)

    De Dominicis, F; Fourdrain, A; Iquille, J; Toublanc, B; François, G; Basille, D; Monconduit, J; Merlusca, G; Jounieaux, V; Andrejak, C; Berna, P

    2015-08-01

    We studied the non-surgical invasive staging by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and we detailed the differences of our series, in order to understand the criteria allowing to achieve a better performance. Retrospective observational study conducted between 2007 and 2011, including all patients with proven NSCLC who underwent EBUS-TBNA. For the 92 EBUS-TBNA performed, we found a sensitivity of 78%, a specificity of 93%, a positive predictive value (PPV) of 98%, a negative predictive value (NPV) of 45%, an accuracy of 80% and a prevalence of lymph node involvement at 84%. A learning curve has been demonstrated and a significant difference was found based on the number of punctures by procedure (P=0.02) or on histological type (P=0.02). By analyzing the data of the literature, we have been able to demonstrate that the accuracy and the negative predictive value are correlated with the prevalence. If we take into account this correlation, we can consider the results of our study close to those of the literature. We highlighted a number of criteria that will influence the diagnostic yield of EBUS-TBNA. While some have already been described, other criteria such as histological type or patient selection criteria are less discussed. The key point is the correlation between the prevalence and EBUS-TBNA results. Results of the assessment of lymph node involvement techniques should be interpreted according to the prevalence of lymph node involvement. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  12. A technique to improve diagnostic information from fine-needle aspirations: immunohistochemistry on cytoscrape

    DEFF Research Database (Denmark)

    Skov, Birgit Guldhammer; Kiss, Katalin; Ramsted, Julie

    2009-01-01

    BACKGROUND: Cytologic examination of fine-needle aspiration (FNA) material is being used increasingly for the diagnosis of pulmonary lesions. Accurate distinction between nonsmall cell lung cancer (NSCLC), including subgroups, and small cell lung cancer and between primary lung cancer and metasta...

  13. Minimum Effective Volume of Lidocaine for Ultrasound-Guided Costoclavicular Block.

    Science.gov (United States)

    Sotthisopha, Thitipan; Elgueta, Maria Francisca; Samerchua, Artid; Leurcharusmee, Prangmalee; Tiyaprasertkul, Worakamol; Gordon, Aida; Finlayson, Roderick J; Tran, De Q

    This dose-finding study aimed to determine the minimum effective volume in 90% of patients (MEV90) of lidocaine 1.5% with epinephrine 5 μg/mL for ultrasound-guided costoclavicular block. Using an in-plane technique and a lateral-to-medial direction, the block needle was positioned in the middle of the 3 cords of the brachial plexus in the costoclavicular space. The entire volume of lidocaine was deposited in this location. Dose assignment was carried out using a biased-coin-design up-and-down sequential method, where the total volume of local anesthetic administered to each patient depended on the response of the previous one. In case of failure, the next subject received a higher volume (defined as the previous volume with an increment of 2.5 mL). If the previous patient had a successful block, the next subject was randomized to a lower volume (defined as the previous volume with a decrement of 2.5 mL), with a probability of b = 0.11, or the same volume, with a probability of 1 - b = 0.89. Success was defined, at 30 minutes, as a minimal score of 14 of 16 points using a sensorimotor composite scale. Patients undergoing surgery of the elbow, forearm, wrist, or hand were prospectively enrolled until 45 successful blocks were obtained. This clinical trial was registered with ClinicalTrials.gov (ID NCT02932670). Fifty-seven patients were included in the study. Using isotonic regression and bootstrap confidence interval, the MEV90 for ultrasound-guided costoclavicular block was estimated to be 34.0 mL (95% confidence interval, 33.4-34.4 mL). All patients with a minimal composite score of 14 points at 30 minutes achieved surgical anesthesia intraoperatively. For ultrasound-guided costoclavicular block, the MEV90 of lidocaine 1.5% with epinephrine 5 μg/mL is 34 mL. Further dose-finding studies are required for other concentrations of lidocaine, other local anesthetic agents, and multiple-injection techniques.

  14. CT-guided preoperative needle localization of MRI-detected breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Giagounidis, Elektra M. E-mail: giagounjdis@online.de; Markus, Ruwe; Josef, Luetzeler; Wemer, Audretsch; Mahdi, Rezai; Bernward, Kurtz

    2001-08-01

    To assess the value of accurate preoperative CT-guided needle localization of occult breast lesions, we reviewed a total of 39 needle-directed biopsies of breast tumors in 24 women. The average age was 52.9 years (range 31-67). All lesions were nonpalpable and mammographically, as well as sonographically occult. They were solely seen on MR-images. After demonstrating the suspicious region on CT scans, a hookwire was inserted. The correct position was confirmed by a control scan. The subsequent histopathological examination showed that 28 of the lesions (71.8%) were benign, among them mastopathy, fibrosis, fibroadenoma, papilloma, intramammary lymph node, liponecrosis and epitheliosis. Eleven lesions (28%) were malignant and showed either lobular, ductal or tubular cancer. Our results endorse that CT guided needle localization is a helpful method that allows a precise surgical excision of the suspect area with the removal of a minimal amount of breast tissue.

  15. Clinical Value of CT-Guided Needle Biopsy for Retroperitoneal Lesions

    International Nuclear Information System (INIS)

    Tomozawa, Yuki; Inaba, Yoshitaka; Yamaura, Hidekazu; Sato, Yozo; Kato, Mina; Kanamoto, Takaaki; Sakane, Makoto

    2011-01-01

    The purpose of this study was to investigate retrospectively the clinical procedural performance of CT-guided needle biopsy for retroperitoneal lesions. CT-guided needle biopsy was performed in 74 consecutive patients (M:F = 44:30; mean age, 59.7 years) with retroperitoneal lesions between April 1998 and June 2009. The target lesion ranged from 1.5 to 12.5 cm in size. The biopsy access path ranged from 3.5 to 11.5 cm in depth. A biopsy specimen was obtained using an 18-gauge core needle under a CT or CT-fluoroscopy guidance and with the patient under local anesthesia. The histopathological diagnoses from the biopsies were obtained. The diagnostic confirmation of the subtype of lymphoma was evaluated. Satisfactory biopsy samples were obtained in 73 (99%) of 74 patients and a pathological diagnosis was made in 70 (95%) of 74 patients. Sixty three lesions were malignant (45 lymphomas, nine primary tumors, nine lymph node metastases) and seven were benign. The subtype of lymphoma was specified in 43 (96%) of 45 patients who were diagnosed with lymphoma. Analysis of the value of CT-guided biopsy in this series indicated 63 true positives, zero false positive, six true negatives and five false negatives. This test had a sensitivity of 93%, a specificity of 100% and an accuracy of 93%. No major complications were seen and minor complications were noted in seven patients (five with local hematomas, two with transient pain at the puncture site). CT-guided needle biopsy for retroperitoneal lesions is highly practical and useful, and particularly for determining the subtypes in patients with lymphoma.

  16. Comparative cost-effectiveness of fine needle aspiration biopsy versus image-guided biopsy, and open surgical biopsy in the evaluation of breast cancer in the era of Affordable Care Act: a changing landscape.

    Science.gov (United States)

    Masood, Shahla; Rosa, Marilin; Kraemer, Dale F; Smotherman, Carmen; Mohammadi, Amir

    2015-08-01

    Proven as a time challenged and cost-effective sampling procedure, the use of FNAB has still remained controversial among the scientific community. Currently, other minimally invasive sampling procedures such as ultrasound guided fine needle aspiration biopsy (US-FNAB) and image guided core needle biopsy (IG-CNB) have become the preferred sampling procedures for evaluation of breast lesions. However, changes in the medical economy and the current growing emphasis on cost containment in the era of the Affordable Care Act make it necessary to stimulate a renewed interest in the use of FNAB as the initial diagnostic sampling procedure. This study was designed to define the changing trend in the practice of tissue sampling during the last several years, and to assess the comparative effectiveness and appropriateness of the procedure of choice for breast cancer diagnosis. After Institutional Review Board (IRB) approval, the computer database of the Pathology Department, University of Florida, College of Medicine-Jacksonville at UF Health was retrospectively searched to identify all breast biopsy pathology reports issued during the period of January 2004 to December 2011. The inclusion criteria were all women that underwent any of the following biopsy types: FNAB, US-FNAB, IG-CNB, and surgical biopsy (SB). Diagnostic procedures were identified using current procedural terminology (CPT) codes recorded on claims from the UF Health Jacksonville patient accounting application files. The data obtained was used to determine which technique has the best cost-effectiveness in the diagnosis of breast cancer. The outcome variable for this project was a positive breast cancer diagnosis resulting from these methodologies. The predictor variable was the biopsy type used for sampling. The rate of cancer detection for each procedure was also determined. Among the four groups of procedures compared, the lower cost was attributed to FNAB, followed by US-FNAB, and SB. IG-CNB was the most

  17. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    Science.gov (United States)

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  18. Comparison of the development of performance skills in ultrasound-guided regional anesthesia simulations with different phantom models.

    Science.gov (United States)

    Liu, Yang; Glass, Nancy L; Glover, Chris D; Power, Robert W; Watcha, Mehernoor F

    2013-12-01

    Ultrasound-guided regional anesthesia (UGRA) skills are traditionally obtained by supervised performance on patients, but practice on phantom models improves success. Currently available models are expensive or use perishable products, for example, olive-in-chicken breasts (OCB). We constructed 2 inexpensive phantom (transparent and opaque) models with readily available nonperishable products and compared the process of learning UGRA skills by novice practitioners on these models with the OCB model. Three experts first established criteria for a satisfactory completion of the simulated UGRA task in the 3 models. Thirty-six novice trainees (simulations was accomplished. The number of errors, needle passes, and time for task completion per attempt progressively decreased in all 3 groups. However, failure to identify the target and to visualize the needle on the ultrasound image occurred more frequently with the OCB model. The time to complete simulator training was shortest with the transparent model, owing to shorter target identification times. However, trainees were less likely to agree strongly that this model was realistic for teaching UGRA skills. Training on inexpensive synthetic simulation models with no perishable products permits learning of UGRA skills by novices. The OCB model has disadvantages of containing potentially infective material, requires refrigeration, cannot be used after multiple needle punctures, and is associated with more failures during simulated UGRA. Direct visualization of the target in the transparent model allows the trainee to focus on needle insertion skills, but the opaque model may be more realistic for learning target identification skills required when UGRA is performed on real patients in the operating room.

  19. Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    International Nuclear Information System (INIS)

    Thompson, S.A.; Fung, A.Y.C.; Zaider, M.

    2002-01-01

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results. (author)

  20. Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, S.A. [Department of Medical Physics, North Shore-Long Island Jewish Health System, Manhassett, NY (United States); Fung, A.Y.C.; Zaider, M. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2002-08-21

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results. (author)

  1. Rapid on-site evaluation of axillary fine-needle aspiration cytology in breast cancer.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2012-06-01

    Axillary ultrasonography (AUS) and fine-needle aspiration cytology (FNAC) can establish axillary lymph node status before surgery, although this technique is hampered by poor adequacy rates. To achieve consistently high rates of FNAC adequacy, rapid on-site evaluation (ROSE) of FNAC samples was introduced.

  2. Risk of malignancy in fine-needle aspiration biopsy in patients with thyroid nodules

    DEFF Research Database (Denmark)

    Egset, Alice Viktoria; Holm, Camilla; Larsen, Stine Rosenkilde

    2017-01-01

    Introduction: Fine-needle aspiration biopsy (FNAB) is the cornerstone of thyroid nodule evaluation. In most cases, FNAB can discriminate between benign and malignant disease. In other cases, it is only indicative of malignancy and the results are considered “suspicious”. In Denmark, thyroid FNAB...

  3. Pneumothorax and the Value of Chest Radiography after Ultrasound-Guided Thoracocentesis

    International Nuclear Information System (INIS)

    Pihlajamaa, K.; Bode, M.K.; Puumalainen, T.; Lehtimaeki, A.; Marjelund, S.; Tikkakoski, T.

    2004-01-01

    Purpose: To determine the incidence, the operator's experience, and other variables that may influence the development of pneumothorax or re-expansion edema after ultrasound (US)-guided thoracocentesis. Material and Methods: The medical records of 264 procedures in 212 patients who had undergone US-guided thoracocentesis in our radiology department or intensive care unit during the period 1996-2001 were retrospectively reviewed. Results: Post-thoracocentesis pneumothorax occurred in 11 cases, the incidence being 4.2% (11/264). None of the pneumothoraces occurred in the 10 mechanically ventilated patients. All but one patient with pneumothorax were asymptomatic or had only minor symptoms. Chest tube drainage was needed in one patient with a large pneumothorax. No re-expansion edema was recorded, although 1500 ml or more pleural fluid was aspirated in 29 patients. The operator's experience had no effect on the complication rate. Needle size was the only significant variable that contributed to the pneumothorax rate. Conclusion: US-guided thoracocentesis can be done equally as safely by residents as by senior radiologists. The safety and feasibility of the method are evident among mechanically ventilated intensive care patients. Our results do not support the routine use of post-thoracocentesis chest radiography

  4. Development of an ultrasound-guided technique for retrobulbar nerve block in dromedary camels: a cadaveric study.

    Science.gov (United States)

    Badawy, Adel M; Eshra, Eman A

    2018-03-01

    Description of an ultrasound (US)-guided technique for retrobulbar nerve blockade in dromedary (Camelus dromedarius) cadavers. Prospective experimental cadaveric study that was carried out in three phases: phase I: anatomical dissection and development of US-guided technique; phase II: methylene blue (MB) injection; phase III: contrast medium (CM), US-guided injections with computed tomography (CT) control. A total of 36 orbits from 18 heads were obtained from 18 dromedary cadavers. Phase I: anatomical dissections were carried out bilaterally, using two heads to determine needle site placement. Phase II: a US-guided, lateral, in-plane approach using one of three volumes of MB (3, 6, or 9 mL) was evaluated in six heads (four orbits per volume tested) to establish the ideal injection volume. Injections of MB that strongly stained all retrobulbar nerves were considered successful, whereas insufficient MB volumes resulted in weak or no nerve staining. Phase III: US-guided retrobulbar injection with CM was carried out using 20 orbits. Computed tomography was performed after each injection trial to determine the accuracy of needle placement and CM dispersal. An injection was judged to be successful when the CT images revealed that the needle was located within the retractor bulbi muscle cone and the CM reached the target nerves at the orbitorotundum and the optic foramina. Only injection of 9 mL of MB stained the target nerves sufficiently, whereas there was no or only weak staining with 3 and 6 mL, respectively. Therefore, 9 mL of CM was used for the US-guided injections in phase III. Subsequent CT scans revealed satisfying CM distribution within the ocular muscle cone in 18 of 20 cases (90% success rate). US-guided retrobulbar injection in dromedary cadavers is feasible. Further research is required to assess its practicality and usefulness in vivo. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and

  5. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    Science.gov (United States)

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion

  6. Punción pancreática ecodirigida: estudio multicéntrico Ultrasound-guided biopsy of the pancreas: A multicenter study

    Directory of Open Access Journals (Sweden)

    M. C. Garre Sánchez

    2007-09-01

    Full Text Available Objetivo: en el seno de la Asociación de Ecografía Digestiva se decidió realizar un estudio retrospectivo multicéntrico sobre la punción-aspiración con aguja fina (PAAF de lesiones ocupantes de espacio pancreáticas, mediante control ecográfico y por vía percutánea, con el objetivo de valorar el rendimiento de dicha técnica y poder compararla con la punción mediante ultrasonografía endoscópica. Participantes: en el estudio han participado 10 hospitales con 222 pacientes con lesiones pancreáticas entre 8 y 120 mm, sospechosas de malignidad. Resultados: el análisis de los resultados muestra una sensibilidad del 89%, especificidad 98%, valor predictivo positivo 99% y negativo 74%, con precisión diagnóstica global 91%. No encontramos ninguna complicación significativa. Conclusión: la PAAF de lesiones pancreáticas por vía percutánea es de alta rentabilidad diagnóstica y con pocas y leves complicaciones.Objective: members of "Asociación de Ecografía Digestiva" decided to carry out a multicenter retrospective study on fine-needle aspiration biopsy for pancreatic space-occupying lesions under ultrasonographic guidance and via the percutaneous route in order to assess this technique's performance versus endoscopic ultrasound-guided biopsy. Subjects: 10 hospitals for a total of 222 patients with suspiciously malignant, 8-120-mm pancreatic lesions were included in the study. Results: the analysis of results shows a sensitivity of 89%, a specificity of 98%, a positive predictive value of 99%, and a negative predictive value of 74%, for an overall diagnostic accuracy of 91%. No major complications occurred. Conclusion: percutaneous fine-needle aspiration for pancreatic lesions is highly cost-effective and has few and mild complications.

  7. CT-guided transthoracic cutting needle biopsy of intrathoracic lesions: Comparison between coaxial and single needle technique

    International Nuclear Information System (INIS)

    Wu, Reng-Hong; Tzeng, Wen-Sheng; Lee, Wei-Jing; Chang, Shih-Chin; Chen, Chia-Huei; Fung, Jui-Lung; Wang, Yen-Jen; Mak, Chee-Wai

    2012-01-01

    Purpose: To evaluate the complication rates and diagnostic accuracy of two different CT-guided transthoracic cutting needle biopsy techniques: coaxial method and single needle method. Methods: This study involved 198 consecutive subjects with 198 intrathoracic lesions. The first 98 consecutive subjects received a single needle cutting technique and the next 100 consecutive subjects received a coaxial technique. Both groups were compared in relation the diagnostic accuracy and complication rates. Results: No significant difference was found between the two groups concerning patient characteristics, lesions and procedure variables. There was a borderline statistical difference in the incidence of pneumothorax at within 24-h post biopsy between patients in the single needle group (5%) and the coaxial group (13%) (P = 0.053). Little difference was found in the pneumothorax rate at immediately post biopsy between the two groups, which was 28% in the single needle group and 31% in the coaxial group. There was no significant difference in the hemoptysis rate between the two groups, which was 9.2% in the single needle group and 11% in the coaxial group. Both techniques yielded an overall diagnostic accuracy of 98% for malignant lesions with similar sensitivity (single needle: 96.9% vs. coaxial: 96.4%) and specificity (single needle: 100% vs. coaxial: 100%). Conclusion: There is little difference in the pneumothorax rates and bleeding complications between patients who either received a single needle or a coaxial transthoracic cutting biopsy. Both techniques produce an overall diagnostic accuracy of 98% for malignant lesions.

  8. Clinical utility of routine pre-operative axillary ultrasound and fine needle aspiration cytology in patient selection for sentinel lymph node biopsy.

    Science.gov (United States)

    Rattay, T; Muttalib, M; Khalifa, E; Duncan, A; Parker, S J

    2012-04-01

    In patients with operable breast cancer, pre-operative evaluation of the axilla may be of use in the selection of appropriate axillary surgery. Pre-operative axillary ultrasound (US) and fine needle aspiration cytology (FNAC) assessments have become routine practice in many breast units, although the evidence base is still gathering. This study assessed the clinical utility of US+/-FNAC in patient selection for either axillary node clearance (ANC) or sentinel lymph node biopsy (SLNB) in patients undergoing surgery for operable breast cancer. Over a two-year period, 348 patients with a clinically negative axilla underwent axillary US. 67 patients with suspicious nodes on US also underwent FNAC. The sensitivity and specificity of axillary investigations to determine nodal involvement were 56% (confidence interval: 47-64%) and 90% (84-93%) for US alone, and 76% (61-87%) and 100% (65-100%) for FNAC combined with US, respectively. With a positive US, the post-test probability was 78%. A negative US carried a post-test probability of 25%. When FNAC was positive, the post-test probability was greater than unity. A negative FNAC yielded a post-test probability of 52%. All patients with positive FNAC and most patients with suspicious US were listed for axillary node clearance (ANC) after consideration at the multi-disciplinary team (MDT) meeting. With pre-operative axillary US+/-FNAC, 20% of patients were saved a potential second axillary procedure, facilitating a reduction in the overall re-operation rate to 12%. In this study, a positive pre-operative US+/-FNAC directs patients towards ANC. When the result is negative, other clinico-pathological factors need to be taken into account in the selection of the appropriate axillary procedure. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. A randomized comparison between costoclavicular and paracoracoid ultrasound-guided infraclavicular block for upper limb surgery.

    Science.gov (United States)

    Leurcharusmee, Prangmalee; Elgueta, Maria Francisca; Tiyaprasertkul, Worakamol; Sotthisopha, Thitipan; Samerchua, Artid; Gordon, Aida; Aliste, Julian; Finlayson, Roderick J; Tran, De Q H

    2017-06-01

    This two-centre randomized trial compared costoclavicular and paracoracoid ultrasound-guided infraclavicular brachial plexus block in patients undergoing upper limb surgery. We hypothesized that both techniques would result in similar onset times and designed the study as an equivalence trial. Ninety patients undergoing upper limb surgery at or distal to the elbow were randomly allocated to receive a costoclavicular (n = 45) or paracoracoid (n = 45) ultrasound-guided infraclavicular brachial plexus block. Both groups received a 35-mL mixture of 1% lidocaine-0.25% bupivacaine with epinephrine 5 µg·mL -1 . In the costoclavicular group, local anesthetic was injected into the costoclavicular space in the middle of the three cords of the brachial plexus. In the paracoracoid group, local anesthetic was deposited dorsal to the axillary artery in the lateral infraclavicular fossa. A blinded observer recorded the block onset time (primary endpoint), success rate (i.e., surgical anesthesia), block-related pain scores, as well as the incidence of hemidiaphragmatic paralysis. Performance time and the number of needle passes were also recorded during the performance of the block. The total anesthesia-related time was defined as the sum of the performance and onset times. The mean (SD) onset times were comparable between the costoclavicular and paracoracoid groups [16.0 (7.5) min vs 16.8 (6.2) min, respectively; mean difference, 0.8; 95% confidence interval, -2.3 to 3.8; P = 0.61]. Furthermore, no intergroup differences were found in terms of performance time (P = 0.09), total anesthesia-related time (P = 0.90), surgical anesthesia (P > 0.99), and hemidiaphragmatic paralysis (P > 0.99). The paracoracoid technique required marginally fewer median [interquartile range] needle passes than the costoclavicular technique (2 [1-4] vs 2 [1-6], respectively; P = 0.048); however, procedural pain was comparable between the two study groups. Costoclavicular and paracoracoid ultrasound-guided

  10. Hoarseness of voice after supraclavicular ultrasound-guided subclavian perivascular brachial plexus block

    Directory of Open Access Journals (Sweden)

    Monika Gupta

    2017-01-01

    Full Text Available Supraclavicular brachial plexus nerve block is ideal for surgical procedures at or distal to the elbow. Ultrasound (USG continues to grow in popularity as a method of nerve localization, and for the supraclavicular block, it has the advantage of allowing real-time visualization of the plexus, pleura, and vessels along with the needle and local anesthetic spread, but it may conversely create a false sense of security. The incidence of the recurrent laryngeal nerve (RLN block occurring with supraclavicular approach is 1.3% of patients.[10] Incidence of RLN block with USG-guided supraclavicular block is not known. In this case report, we discuss a rare complication of RLN block which occurred while performing a supraclavicular perivascular block performed under USG guidance.

  11. CT fluoroscopy guided transpleural cutting needle biopsy of small ({<=}2.5 cm) subpleural pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut; Oschatz, Elisabeth; Eisenhuber, Edith; Wohlschlager, Helmut [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria); Mostbeck, Gerhard H., E-mail: gerhard.mostbeck@wienkav.at [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria)

    2011-01-15

    Purpose: Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions. Material and methods: Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura. Results: Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required. Conclusion: The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes.

  12. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  13. Ultrasound-guided interstitial brachytherapy in the treatment of advanced vaginal recurrences from cervical and endometrial carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Weitmann, H.D.; Knocke, T.H.; Waldhaeusl, C.; Poetter, R. [Dept. of Radiotherapy and Radiobiology, Medical Univ. of Vienna (Austria)

    2006-02-01

    Background: in advanced vaginal recurrences of cervical and endometrial carcinomas therapeutic options are rare because of preceding therapy. Patients and methods: 23 patients developing advanced vaginal recurrences of cervical and endometrial carcinomas were included. 15 patients started with external-beam therapy to the pelvis and eight patients after preceding radiotherapy underwent brachytherapy alone. All patients had ultrasound-guided implantation of transvaginal or transperineal interstitial needles for brachytherapy. Median prescribed total dose was 64 Gy. Results: 18 patients (78%) achieved complete remission. Six patients are alive without tumor and one with tumor after a median follow-up of 64 months. 14 patients died of tumor and two of intercurrent disease. 5-year disease-specific survival and local control rate were 43% and 47%, respectively, in patients with complete remission. Univariate analysis found time to relapse > 2 years, initial diameter {<=} 4 cm, initial volume < 15 cm{sup 3}, no extension to the pelvic side wall, volume before brachytherapy < 7.5 cm{sup 3}, brachytherapy coverage index > 0.8, and prescribed total dose > 64 Gy being positive predictors for local control and survival. Conclusion: the use of ultrasound guidance for placement of interstitial needles in template-based brachytherapy of advanced recurrent gynecologic malignancies is a feasible, safe, and cheap method with encouraging results. Today, ultrasound imaging can be also used to some extent for treatment planning which requires further development. Patient- and treatment-related prognostic factors can be defined. (orig.)

  14. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    Science.gov (United States)

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  15. Impact of Simulation-Based Training on Radiology Trainee Education in Ultrasound-Guided Breast Biopsies.

    Science.gov (United States)

    Roark, Ashley A; Ebuoma, Lilian O; Ortiz-Perez, Tamara; Sepulveda, Karla A; Severs, Frederick J; Wang, Tao; Benveniste, Ana Paula; Sedgwick, Emily L

    2017-12-05

    The aim of this study is to determine the impact of a simulation-based ultrasound-guided (USG) breast biopsy training session on radiology trainee procedural knowledge, comfort levels, and overall procedural confidence and anxiety. Twenty-one diagnostic radiology residents from a single academic institution were recruited to participate in an USG breast biopsy training session. The residents filled out a questionnaire before and after the training session. Ten multiple-choice questions tested general knowledge in diagnostic breast ultrasound and USG breast biopsy concepts. Subjective comfort levels with ultrasound machine and biopsy device functionality, patient positioning, proper biopsy technique, image documentation, needle safety and overall procedural confidence and anxiety levels were reported on a 5-point Likert scale before and after training. Participants demonstrated significant improvement in number of correctly answered general knowledge questions after training (P simulation-based USG breast biopsy training session may improve radiology trainee procedural knowledge, comfort levels, and overall procedural confidence. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. MRI-guided prostate focal laser ablation therapy using a mechatronic needle guidance system

    Science.gov (United States)

    Cepek, Jeremy; Lindner, Uri; Ghai, Sangeet; Davidson, Sean R. H.; Trachtenberg, John; Fenster, Aaron

    2014-03-01

    Focal therapy of localized prostate cancer is receiving increased attention due to its potential for providing effective cancer control in select patients with minimal treatment-related side effects. Magnetic resonance imaging (MRI)-guided focal laser ablation (FLA) therapy is an attractive modality for such an approach. In FLA therapy, accurate placement of laser fibers is critical to ensuring that the full target volume is ablated. In practice, error in needle placement is invariably present due to pre- to intra-procedure image registration error, needle deflection, prostate motion, and variability in interventionalist skill. In addition, some of these sources of error are difficult to control, since the available workspace and patient positions are restricted within a clinical MRI bore. In an attempt to take full advantage of the utility of intraprocedure MRI, while minimizing error in needle placement, we developed an MRI-compatible mechatronic system for guiding needles to the prostate for FLA therapy. The system has been used to place interstitial catheters for MRI-guided FLA therapy in eight subjects in an ongoing Phase I/II clinical trial. Data from these cases has provided quantification of the level of uncertainty in needle placement error. To relate needle placement error to clinical outcome, we developed a model for predicting the probability of achieving complete focal target ablation for a family of parameterized treatment plans. Results from this work have enabled the specification of evidence-based selection criteria for the maximum target size that can be confidently ablated using this technique, and quantify the benefit that may be gained with improvements in needle placement accuracy.

  17. Genomic characterisation of small cell lung cancer patient-derived xenografts generated from endobronchial ultrasound-guided transbronchial needle aspiration specimens.

    Directory of Open Access Journals (Sweden)

    Tracy L Leong

    Full Text Available Patient-derived xenograft (PDX models generated from surgical specimens are gaining popularity as preclinical models of cancer. However, establishment of PDX lines from small cell lung cancer (SCLC patients is difficult due to very limited amount of available biopsy material. We asked whether SCLC cells obtained from endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA could generate PDX lines that maintained the phenotypic and genetic characteristics of the primary tumor. Following successful EBUS-TBNA sampling for diagnostic purposes, we obtained an extra sample for cytologic analysis and implantation into the flanks of immunodeficient mice. Animals were monitored for engraftment for up to 6 months. Histopathologic and immunohistochemical analysis, and targeted next-generation re-sequencing, were then performed in both the primary sample and the derivative PDX line. A total of 12 patients were enrolled in the study. EBUS-TBNA aspirates yielded large numbers of viable tumor cells sufficient to inject between 18,750 and 1,487,000 cells per flank, and to yield microgram quantities of high-quality DNA. Of these, samples from 10 patients generated xenografts (engraftment rate 83% with a mean latency of 104 days (range 63-188. All but one maintained a typical SCLC phenotype that closely matched the original sample. Identical mutations that are characteristic of SCLC were identified in both the primary sample and xenograft line. EBUS-TBNA has the potential to be a powerful tool in the development of new targeting strategies for SCLC patients by providing large numbers of viable tumor cells suitable for both xenografting and complex genomic analysis.

  18. [Ultrasound guided percutaneous nephrolithotripsy].

    Science.gov (United States)

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  19. Conclusiveness of fine needle aspiration in 2419 histologically confirmed benign and malignant breast lesions

    NARCIS (Netherlands)

    Kooistra, B.; Wauters, C.; Wobbes, T.; Strobbe, L.

    2011-01-01

    We aimed to retrospectively assess (1) the conclusiveness of breast fine needle aspiration (FNA) in a histologically confirmed population and (2) the clinical and radiologic determinants of a conclusive diagnosis. Aspirates were diagnosed as inadequate, benign, atypical, suspicious or malignant. We

  20. A new robotic needle insertion method to minimise attendant prostate motion

    International Nuclear Information System (INIS)

    Lagerburg, Vera; Moerland, Marinus A.; Vulpen, Marco van; Lagendijk, Jan J.W.

    2006-01-01

    Background and purpose: The purpose of this study is to investigate the efficacy of a new needle insertion method (tapping instead of pushing) in reducing attendant tissue motion. This can be useful in applications where tissue motion due to needle insertion is problematic such as e.g. MRI-guided prostate brachytherapy and breast biopsies. In this study we will focus on prostate motion due to needle insertion. Material and methods: Prostate motion due to needle insertion was measured in 30 patients, who were transperineally implanted with fiducial gold markers for position verification in prostate intensity modulated radiotherapy. In total 32 needles were manually pushed into the prostate and 29 were tapped with a prototype robotic system. The prostate motion in the cranio-caudal direction was measured on the video record of the ultrasound images. Differences in prostate motion between the two needle insertion methods were analysed making use of SPSS. Results: The mean prostate motion was 5.6 mm (range 0.3-21.6) when the needle was pushed and 0.9 mm (range 0-2.0) when the needle was tapped into the prostate (p < 0.001). Conclusion: Prostate motion was significantly less when the needle was tapped into the prostate compared to when the needle was pushed. This result is important for the development of a tapping, MRI-guided, prostate implant robotic system

  1. Experimental study on venography with carbon dioxide by fine-needle direct-puncture of abdominal viscera

    International Nuclear Information System (INIS)

    Zhu Chi; Xu Changliang; Zhang Dezhi; Zheng Feiqun; Sheng Qiang; Zhang Xiuze; Xiong Zhuang; Yu Yongqiang

    2005-01-01

    Objective: To evaluate the feasibility and safety of CO 2 venography by fine-needle direct-puncture of abdominal viscera. Methods: Two healthy female pigs and two healthy female dogs were used in this study. Multi-point punctures of abdominal viscera including liver, spleen, kidney, pancreas, walls of small intestines, and uterus with 25-gauge needle were performed for CO 2 venography in all animals. Diagnostic image quality of the angiographic images was assessed by 3 independent observers. Results: Splenic-portal vein, hepatic vein, portal vein, renal vein and inferior vena cava, uterine vein and ovarian vein could be visualized by fine needle direct CO 2 injection into the related organic parenchyma, while draining vein of small intestines and pancreas could not be shown. Splenic-portal veins were revealed especially well with grade A of 87.5% (7/8) , grade B of 12.5% (1/8), and grade C of 0%. The image quality of hepatic veins were 81.8% (9/11), 18.2% (2/11), and 0% for grade A, B, and C, respectively. The portal veins were 77.8% (7/9), 22.2%(2/9), and 0% for grade A, B, and C, respectively. The renal vein and inferior vena cava were 38.5% (5/13), 61.5% (8/13), and 0% for grade A, B, and C respectively. The uterine veins and ovarian veins were 0%, 33.3% (2/6), and 66.7% (4/6) for grade A, B, and C, respectively. During the CO 2 angiographic procedure, vital signs remained stable in all animals. Conclusion: CO 2 venography with fine-needle direct-puncture of abdominal viscera, excluding small intestines and pancreas, is feasible and safe. (authors)

  2. NOTE: Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    Science.gov (United States)

    Thompson, S. A.; Fung, A. Y. C.; Zaider, M.

    2002-08-01

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results.

  3. Evaluation of the incidence on insufficient cytology results comparing different ultrasound-guided aspiration techniques for thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Hyng; Park, Jun Hyun; Park, Ji Kang [Dept. of Radiology, Jeju National University Hospital, Jeju National University School of Medicine, Jeju (Korea, Republic of)

    2013-07-15

    We compared the incidence of insufficient thyroid cytology due to blood-stained materials or low cellularity in terms of aspiration technique, especially focusing on the degree of suction pressure and needle size. Three experienced radiologists performed ultrasound-guided aspiration for thyroid nodules in 1174 thyroid nodules consecutively. Three different techniques were used; (A) using a 25 gauge needle with mainly capillary technique in 269 nodules; (B) using a 25 gauge needle with 3 cc syringe and minimal suction pressure in 303 nodules; (C) using a 22-23 gauge needle with 10 cc syringe and aspirator in 602 nodules. The differences of the incidence of the insufficient cytology among the three aspiration techniques and relationships of the incidence and needle size/degree of suction pressure was statistically analyzed using the Mann-Whitney U test and the chi-square test with linear-by-linear association. Overall, the difference in insufficient cytology was significant across the three aspiration technique (p = 0.004), and the incidence tended to increase significantly with increase of needle size and degree of suction pressure (p < 0.001). A pairwise comparison of aspiration techniques found significant differences (p = 0.003) between techniques (A) and (C), and no differences between technique (B) and (C) (p 0.07) and between techniques (A) and (B) (p = 0.10). The incidence of insufficient cytology was significantly low in the capillary technique, and it increased significantly with the increase of needle size and degree of suction pressure.

  4. Evaluation of the incidence on insufficient cytology results comparing different ultrasound-guided aspiration techniques for thyroid nodules

    International Nuclear Information System (INIS)

    Kim, Seong Hyng; Park, Jun Hyun; Park, Ji Kang

    2013-01-01

    We compared the incidence of insufficient thyroid cytology due to blood-stained materials or low cellularity in terms of aspiration technique, especially focusing on the degree of suction pressure and needle size. Three experienced radiologists performed ultrasound-guided aspiration for thyroid nodules in 1174 thyroid nodules consecutively. Three different techniques were used; (A) using a 25 gauge needle with mainly capillary technique in 269 nodules; (B) using a 25 gauge needle with 3 cc syringe and minimal suction pressure in 303 nodules; (C) using a 22-23 gauge needle with 10 cc syringe and aspirator in 602 nodules. The differences of the incidence of the insufficient cytology among the three aspiration techniques and relationships of the incidence and needle size/degree of suction pressure was statistically analyzed using the Mann-Whitney U test and the chi-square test with linear-by-linear association. Overall, the difference in insufficient cytology was significant across the three aspiration technique (p = 0.004), and the incidence tended to increase significantly with increase of needle size and degree of suction pressure (p < 0.001). A pairwise comparison of aspiration techniques found significant differences (p = 0.003) between techniques (A) and (C), and no differences between technique (B) and (C) (p 0.07) and between techniques (A) and (B) (p = 0.10). The incidence of insufficient cytology was significantly low in the capillary technique, and it increased significantly with the increase of needle size and degree of suction pressure.

  5. Comparison of clinical marking and ultrasound-guided injection of Botulinum type A toxin into the masseter muscles for treating bruxism and its cosmetic effects.

    Science.gov (United States)

    Quezada-Gaon, Natacha; Wortsman, Ximena; Peñaloza, Osvaldo; Carrasco, Juan Eduardo

    2016-09-01

    Botulinum toxin type A has been used for treating the hypertrophy of the masseter muscles and its cosmetic effects. Ultrasound is increasingly used in dermatology, along with the guidance of mini-invasive procedures. To evaluate the role of ultrasound for guiding the application of Botulinum A toxin in patients with cosmetic alterations due to bruxism, correlate the clinical landmarks with the ultrasound findings, and study the effect on the symptoms, cosmetics, and quality of life. Twenty individuals with bruxism and cosmetic alterations underwent an ultrasound-guided injection of Botulinum toxin type A in each masseter muscle. Clinical and ultrasound marking of the procedure was compared. Clinical and sonographic evaluation was performed at the time of injection and 3 months later. Ten normal individuals underwent ultrasound of the masseter muscles as a control group. Up to 65% of individuals showed anatomical variants of the salivary glands. The method for clinically marking the skin showed a frequently erroneous location of the anterior point (up to 40% of cases) that was proven by ultrasound to be out of the muscle. In 20% of cases, ultrasound showed that the needle should be longer to enter the muscle. After injection, most of the patients demonstrated a decrease of the symptoms and cosmetic and quality of life improvements. Ultrasound can be a potent tool for guiding the injection of Botulinum toxin into the masseter muscles. It may contribute to a more personalized procedure, better cosmetic results, and help to avoid potential complications. © 2016 Wiley Periodicals, Inc.

  6. Inexpensive homemade models for ultrasound-guided vein cannulation training.

    Science.gov (United States)

    Di Domenico, Stefano; Santori, Gregorio; Porcile, Elisa; Licausi, Martina; Centanaro, Monica; Valente, Umberto

    2007-11-01

    To test the hypothesis that low-cost homemade models may be used to acquire the basic skills for ultrasound-guided central vein puncture. Training study. University transplantation department. Training was performed using three different homemade models (A, B, and C). Segments of a common rubber tourniquet (V1) and Silastic tube (V2) were used to simulate vessels within agar-based models. Overall cost for each model was less than 5 euro (US$7). For each test (test I, A-V1; II, A-V2; III, B-V1; IV, C-V2), the number of punctures and attempts needed to locate the needle inside the lumen were recorded. Each test was considered completed when participants punctured the vessels at the first attempt for three consecutive times. In test I, the mean number of punctures and attempts were 3.85 +/- 1.26 and 4.95 +/- 3.05; in test II, 4.60 +/- 1.14 and 6.30 +/- 2.51; in test III, 4.80 +/- 1.06 and 4.65 +/- 2.21; and in test IV, 4.45 +/- 1.23 and 6.05 +/- 2.92, respectively. For each test, no statistical difference was found by comparison of number of punctures and attempts for anesthesiologists versus nonanesthesiologists, men versus women, or previous experience versus no experience with central vein cannulation (CVC). Video game users obtained better results than did nonusers in test I (punctures, P = 0.033; attempts, P = 0.038), test II (punctures, P = 0.052; attempts, P = 0.011), and test IV (punctures, P = 0.001; attempts, P = 0.003). A posttraining questionnaire showed favorable opinions about the clarity of the instructions, aptness of the models, and adequacy of the training. In our operative unit, the use of ultrasound guidance for CVC increased from 2% to 23% in the first month after training. Low-cost homemade models are useful in acquiring basic coordination skills for ultrasound-guided CVC.

  7. Development of a high frequency single-element ultrasound needle transducer for anesthesia delivery

    Science.gov (United States)

    Ameri, Golafsoun; Son, Jungik; Liang, Jingwei; Foster, F. Stuart; Ganapathy, Sugantha; Peters, Terry M.

    2017-03-01

    Epidural anesthesia is one of the most commonly used and yet challenging techniques employed for pain management and anesthesia delivery. The major complications of this procedure are due to accidental dural puncture, with an incidence of 1-3%, which could lead to both temporary and irreversible permanent neurological complications. Needle placement under ultrasound (US) guidance has received increasing interest for improving needle placement accuracy. However, poor needle visibility in US, difficulties in displaying relevant anatomical structure such as dura mater due to attenuation and bone shadowing, and image interpretation variability among users pose significant hurdles for any US guidance system. As a result, US guidance for epidural injections has not been widely adopted for everyday use for the performance of neuraxial blocks. The difficulties in localizing the ligamentum flavum and dura with respect to the needle tip can be addressed by integrating A-mode US, provided by a single-element transducer at the needle tip, into the B-mode US guidance system. We have taken the first steps towards providing such a guidance system. Our goal is to improve the safety of this procedure with minimal changes to the clinical workflow. This work presents the design and development of a 20 MHz single-element US transducer housed at the tip of a 19 G needle hypodermic tube, which can fit inside an epidural introducer needle. In addition, the results from initial transducer characterization tests and performance evaluation of the transducer in a euthanized porcine model are provided.

  8. Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions

    International Nuclear Information System (INIS)

    Hryhorczuk, Anastasia L.; Strouse, Peter J.; Biermann, J.S.

    2011-01-01

    CT-guided percutaneous core needle biopsy has been shown in adults to be an effective diagnostic tool for a large number of musculoskeletal malignancies. To characterize our experience with CT-guided percutaneous core needle biopsy of pediatric bone lesions and determine its utility in diagnosing pediatric osseous lesions, in a population where such lesions are commonly benign. From 2000 to 2009, 61 children underwent 63 CT-guided percutaneous biopsies. Radiological, pathological and clinical records were reviewed. Fourteen biopsies (22%) were performed on malignant lesions, while 49 biopsies (78%) were performed on benign lesions. Forty-nine of the 63 biopsies (78%) were adequate; these children underwent no further tissue sampling. Fourteen of the 63 biopsies (22%) were inadequate or non-conclusive. Of these patients, 12 underwent open biopsy. Retrospective analysis of percutaneous biopsies in these patients demonstrates that 9/12 provided clinically relevant information, and 4/12 patients received final diagnoses that confirmed initial core biopsy findings. No malignancies were diagnosed as benign on percutaneous biopsy. Overall, percutaneous core needle biopsy provided accurate diagnostic information in 84% (53/63) of biopsies. Our results demonstrate that CT-guided percutaneous biopsy is safe and beneficial in children. This study supports the use of CT-guided percutaneous core needle biopsy for primary diagnosis of pediatric bone lesions. (orig.)

  9. Development of a Novel Ultrasound-guided Peritonsillar Abscess Model for Simulation Training.

    Science.gov (United States)

    Ng, Vivienne; Plitt, Jennifer; Biffar, David

    2018-01-01

    Peritonsillar abscess (PTA) is the most common deep space infection of the head and neck presenting to emergency departments.1 No commercial PTA task trainer exists for simulation training. Thus, resident physicians often perform their first PTA needle aspiration in the clinical setting, knowing that carotid artery puncture and hemorrhage are serious and devastating complications. While several low-fidelity PTA task trainers have been previously described, none allow for ultrasound image acquisition.6-9 We sought to create a cost-effective and realistic task trainer that allows trainees to acquire both diagnostic ultrasound and needle aspiration skills while draining a peritonsillar abscess. We built the task trainer with low-cost, replaceable, and easily cleanable materials. A damaged airway headskin was repurposed to build the model. A mesh wire cylinder attached to a wooden base was fashioned to provide infrastructure. PTAs were simulated with a water and lotion solution inside a water balloon that was glued to the bottom of a paper cup. The balloon was fully submerged with ordnance gelatin to facilitate ultrasound image acquisition, and an asymmetric soft palate and deviated uvula were painted on top after setting. PTA cups were replaced after use. We spent eight hours constructing three task trainers and used 50 PTA cups for a total cost <$110. Forty-six emergency medicine (EM) residents performed PTA needle aspirations using the task trainers and were asked to rate ultrasound image realism, task trainer realism, and trainer ease of use on a five-point visual analog scale, with five being very realistic and easy. Sixteen of 46 (35%) residents completed the survey and reported that ultrasound images were representative of real PTAs (mean 3.41). They found the model realistic (mean 3.73) and easy to use (mean 4.08). Residents rated their comfort with the drainage procedure as 2.07 before and 3.64 after practicing on the trainer. This low-cost, easy

  10. Development of a Novel Ultrasound-guided Peritonsillar Abscess Model for Simulation Training

    Directory of Open Access Journals (Sweden)

    Vivienne Ng

    2017-12-01

    Full Text Available Introduction Peritonsillar abscess (PTA is the most common deep space infection of the head and neck presenting to emergency departments. 1 No commercial PTA task trainer exists for simulation training. Thus, resident physicians often perform their first PTA needle aspiration in the clinical setting, knowing that carotid artery puncture and hemorrhage are serious and devastating complications. While several low-fidelity PTA task trainers have been previously described, none allow for ultrasound image acquisition. 6– 9 We sought to create a cost-effective and realistic task trainer that allows trainees to acquire both diagnostic ultrasound and needle aspiration skills while draining a peritonsillar abscess. Methods We built the task trainer with low-cost, replaceable, and easily cleanable materials. A damaged airway headskin was repurposed to build the model. A mesh wire cylinder attached to a wooden base was fashioned to provide infrastructure. PTAs were simulated with a water and lotion solution inside a water balloon that was glued to the bottom of a paper cup. The balloon was fully submerged with ordnance gelatin to facilitate ultrasound image acquisition, and an asymmetric soft palate and deviated uvula were painted on top after setting. PTA cups were replaced after use. We spent eight hours constructing three task trainers and used 50 PTA cups for a total cost <$110. Results Forty-six emergency medicine (EM residents performed PTA needle aspirations using the task trainers and were asked to rate ultrasound image realism, task trainer realism, and trainer ease of use on a five-point visual analog scale, with five being very realistic and easy. Sixteen of 46 (35% residents completed the survey and reported that ultrasound images were representative of real PTAs (mean 3.41. They found the model realistic (mean 3.73 and easy to use (mean 4.08. Residents rated their comfort with the drainage procedure as 2.07 before and 3.64 after practicing

  11. Sonoanatomical Change of Phrenic Nerve According to Posture During Ultrasound-Guided Stellate Ganglion Block.

    Science.gov (United States)

    Joeng, Eui Soo; Jeong, Young Cheol; Park, Bum Jun; Kang, Seok; Yang, Seung Nam; Yoon, Joon Shik

    2016-04-01

    To evaluate the risk of phrenic nerve injury during ultrasound-guided stellate ganglion block (US-SGB) according to sonoanatomy of the phrenic nerve, and determine a safer posture for needle insertion by assessing its relationship with surrounding structure according to positional change. Twenty-nine healthy volunteers were recruited and underwent ultrasound in two postures, i.e., supine position with the neck extension and head rotation, and lateral decubitus position. The transducer was placed at the anterior tubercle of the C6 level to identify phrenic nerve. The cross-sectional area (CSA), depth from skin, distance between phrenic nerve and anterior tubercle of C6 transverse process, and the angle formed by anterior tubercle, posterior tubercle and phrenic nerve were measured. The phrenic nerve was clearly identified in the intermuscular fascia layer between the anterior scalene and sternocleidomastoid muscles. The distance between the phrenic nerve and anterior tubercle was 10.33±3.20 mm with the supine position and 9.20±3.31 mm with the lateral decubitus position, respectively. The mean CSA and skin depth of phrenic nerve were not statistically different between the two positions. The angle with the supine position was 48.37°±27.43°, and 58.89°±30.02° with the lateral decubitus position. The difference of angle between the two positions was statistically significant. Ultrasound is a useful tool for assessing the phrenic nerve and its anatomical relation with other cervical structures. In addition, lateral decubitus position seems to be safer by providing wider angle for needle insertion than the supine position in US-SGB.

  12. Usefulness of sono-guided needle puncture for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Choi, Jae Woong; Hong, Suk Ju; Suh, San Il; Yong, Hwan Suk; Kim, Jung Hyuk; Park, Cheol Min; Suh, Won Hyuck; Kim, Myung Gyu

    2000-01-01

    To evaluate the usefulness of sono-guided needle puncture for MR arthrography of the shoulder to locate the path of access and to control the correct placement of the needle into the shoulder. Fifteen patients with suspicion of shoulder pathology were included in this study. Patients were laid in supine positions with the arm extended and slightly abducted, the palm of the hand facing upward. A sonographic unit with a high resolution transducer with 7.5 MHz linear array was used. Axial images in the anterior aspect of the shoulder were obtained to localize the coracoid process and the anteromedical portion of the humerus. Using an aseptic technique, a 21-guage needle was advanced into the shoulder joint under ultrasonographic guidance. When the needle made contract with the articular cartilage of the humeral head, the needle was tiled to position is point in the articular cavity. Solution of 0.1 ml gadopentetate dimeglumine in 25 ml of normal saline was prepared and 12-16 ml was injected into the joint cavity. The intra-articular position of the needle and the compete distension of the shoulder joint were again confirmed by sonography. The needle was accurately placed in 14 out of 15 patients without damage to neighboring structures. It took 10 to 15 minutes to complete the procedure in 14 patients. No side effects attributable to gadopentetate dimeglumine were found. Sono-guided needle puncture for the shoulder MR arthrography can be a substitutable method for fluoroscopic guidance, with easy access, advantages of lacking radiation hazard and eliminating the need for iodized contrast agents.

  13. Cytomorphology of nipple discharge and fine needle aspiration of duct papilloma

    Directory of Open Access Journals (Sweden)

    H B Bannur

    2012-01-01

    Full Text Available The primary role of fine needle aspiration (FNA of the breast is the distinction between benign and malignant lesions; but in many cases, additional information may be obtained. The major breast lesions that yield papillary fragments on FNA are papillary carcinoma, papilloma, fibroadenoma, and invasive ductal carcinoma that have a papillary component. We present cytomorphological features of nipple discharge and FNA of breast lump in a 32-year female.

  14. Fine-needle aspiration cytology in children with superficial lymphadenopathy

    Directory of Open Access Journals (Sweden)

    F. De Corti

    2014-04-01

    Full Text Available Introduction: In pediatric population Fine-Needle Aspiration Citology (FNAC is slowly gaining acceptance in clinical management of Superficial Lymphadenopathy (SL. Our experience adds some data about the usefulness of this technique in diagnosing the cause of a SL and therefore guiding further treatment. Patients and Methods: 238 FNAC were performed in 217 patients with SL, observed at our Institution from 2002 to 2006. The neck was the most frequent localization. The results were available within few hours. In cases of granulomatous findings, the samples were processed for microbiological and PCR test, in order to identify Mycobacteria. Results: 174 were reactive lesions, 38 granulomatous lymphadenopathies, 24 malignant lesions, 2 specimens inadequate for diagnosis. Among the 174 reactive SL, 22 required an incisional biopsy after 1 month follow-up. Among the granulomatous lymphadenopathies, 13 children with Cat-Scratch Disease recovered, 25 with Mycobacteria infection underwent surgical excision. For 24 malignant lesions, the diagnosis was confirmed by further biopsy. Two false negative and no false positive were detected (sensitivity 92%, specificity 100%. No complications were encountered. Conclusions: In our experience FNAC, performed by experienced cytopathologist, has revealed to be a fast, safe, non invasive and inexpensive method to achieve diagnosis in persistent SL. The use of FNAC gave us the possibility to select patients for further investigation and/or surgical treatment. Incisional biopsy remains necessary to confirm the diagnosis in case of malignancy or doubtful lesions.

  15. Two-miRNA classifiers differentiate mutation-negative follicular thyroid carcinomas and follicular thyroid adenomas in fine needle aspirations with high specificity

    DEFF Research Database (Denmark)

    Stokowy, Tomasz; Wojtas, Bartosz; Jarzab, Barbara

    2016-01-01

    Diagnosis of thyroid by fine needle aspiration is challenging for the "indeterminate" category and can be supported by molecular testing. We set out to identify miRNA markers that could be used in a diagnostic setting to improve the discrimination of mutation-negative indeterminate fine needle...... aspirations. miRNA high-throughput sequencing was performed for freshly frozen tissue samples of 19 RAS and PAX8/PPARG mutation-negative follicular thyroid carcinomas, and 23 RAS and PAX8/PPARG mutation-negative follicular adenomas. Differentially expressed miRNAs were validated by quantitative polymerase...... chain reaction in a set of 44 fine needle aspiration samples representing 24 follicular thyroid carcinomas and 20 follicular adenomas. Twenty-six miRNAs characterized by a significant differential expression between follicular thyroid carcinomas and follicular adenomas were identified. Nevertheless...

  16. An inexpensive, easily constructed, reusable task trainer for simulating ultrasound-guided pericardiocentesis.

    Science.gov (United States)

    Zerth, Herb; Harwood, Robert; Tommaso, Laura; Girzadas, Daniel V

    2012-12-01

    Pericardiocentesis is a low-frequency, high-risk procedure integral to the practice of emergency medicine. Ultrasound-guided pericardiocentesis is the preferred technique for providing this critical intervention. Traditionally, emergency physicians learned pericardiocentesis in real time, at the bedside, on critically ill patients. Medical education is moving toward simulation for training and assessment of procedures such as pericardiocentesis because it allows learners to practice time-sensitive skills without risk to patient or learner. The retail market for models for pericardiocentesis practice is limited and expensive. We have developed an ultrasound-guided pericardiocentesis task trainer that allows the physician to insert a needle under ultrasound guidance, pierce the "pericardial sac" and aspirate "blood." Our model can be simply constructed in a home kitchen, and the overall preparation time is 1 h. Our model costs $20.00 (US, 2008). Materials needed for the construction include 16 ounces of plain gelatin, one large balloon, one golf ball, food coloring, non-stick cooking spray, one wooden cooking skewer, surgical iodine solution, and a 4-quart sized plastic food storage container. Refrigeration and a heat source for cooking are also required. Once prepared, the model is usable for 2 weeks at room temperature and may be preserved an additional week if refrigerated. When the model shows signs of wear, it can be easily remade, by simply recycling the existing materials. The self-made model was well liked by training staff due to accessibility of a simulation model, and by learners of the technique as they felt more at ease performing pericardiocentesis on a live patient. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Ultrasound guided electrochemotherapy for the treatment of a clear ...

    African Journals Online (AJOL)

    Ultrasound guided biopsy yielded a diagnosis of clear cell thymoma upon histopathology. After complete staging procedures, the owner elected to treat the cat with electrochemotherapy (ECT) using systemic bleomycin. Two sessions of ultrasound guided ECT were performed at two week intervals with trains of biphasic ...

  18. Biópsia com agulha grossa guiada por ultrassonografia para o diagnóstico dos tumores fibroepiteliais da mama Ultrasound-guided core needle biopsy for the diagnosis of fibroepithelial breast tumors

    Directory of Open Access Journals (Sweden)

    Marcos Desidério Ricci

    2011-01-01

    Full Text Available OBJETIVO: avaliar a taxa de concordância da biópsia percutânea com agulha grossa guiada por ultrassom seguida pela biópsia excisional em nódulos de mama palpáveis, sugestivos de tumores fibroepiteliais. MÉTODO: estudo retrospectivo que selecionou 70 biópsias com diagnóstico histológico de tumor fibroepitelial em 67 dentre 531 pacientes com lesões mamárias submetidas à biópsia percutânea com agulha grossa guiada por ultrassonografia, com transdutor linear de alta frequência (7.5 MHz, utilizando pistola automática Bard-Magnum e agulha 14 gauge. Foram incluídos os casos com diagnóstico de tumor fibroepitelial na biópsia percutânea ou biópsia excisional. Biópsias com diagnóstico histopatológico de fibroesclerose também foram incluídas no estudo. A força da concordância entre o resultado da biópsia percutânea e da biópsia excisional foi medida pelo coeficiente de Kappa. RESULTADOS: a biópsia excisional revelou 40 casos de fibroadenoma (57,1%, 19 de tumor filoide (27,2% e 11 de fibroesclerose (15,7%. A taxa de concordância para o fibroadenoma foi substancial (k = 0,68; IC95% = 0,45 - 0,91, quase perfeita para o tumor filoide (k = 0,81; IC95% = 0,57 - 1,0 e moderada para a fibroesclerose (k = 0,58; IC95% = 0,36 - 0,90. CONCLUSÕES: a biópsia percutânea com agulha grossa é propedêutica minimamente invasiva que tem taxas de concordância com a biópsia excisional, de "substancial" a "quase perfeita". A fibroesclerose deve ser considerada no diagnóstico diferencial dos tumores fibroepiteliais.PURPOSE: to evaluate the concordance rate of ultrasound-guided core needle biopsy followed by excisional biopsy in palpable breast lumps, suggestive of fibroepithelial tumors. METHOD: a retrospective study included 70 biopsies with a histological diagnosis of fibroepithelial tumor in 67 out of 531 patients with breast lesions submitted to ultrasound-guided core needle biopsy with a high frequency (7.5 MHz linear transducer

  19. Oblique needle segmentation and tracking for 3D TRUS guided prostate brachytherapy

    International Nuclear Information System (INIS)

    Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-01-01

    An algorithm was developed in order to segment and track brachytherapy needles inserted along oblique trajectories. Three-dimensional (3D) transrectal ultrasound (TRUS) images of the rigid rod simulating the needle inserted into the tissue-mimicking agar and chicken breast phantoms were obtained to test the accuracy of the algorithm under ideal conditions. Because the robot possesses high positioning and angulation accuracies, we used the robot as a ''gold standard,'' and compared the results of algorithm segmentation to the values measured by the robot. Our testing results showed that the accuracy of the needle segmentation algorithm depends on the needle insertion distance into the 3D TRUS image and the angulations with respect to the TRUS transducer, e.g., at a 10 deg. insertion anglulation in agar phantoms, the error of the algorithm in determining the needle tip position was less than 1 mm when the insertion distance was greater than 15 mm. Near real-time needle tracking was achieved by scanning a small volume containing the needle. Our tests also showed that, the segmentation time was less than 60 ms, and the scanning time was less than 1.2 s, when the insertion distance into the 3D TRUS image was less than 55 mm. In our needle tracking tests in chicken breast phantoms, the errors in determining the needle orientation were less than 2 deg. in robot yaw and 0.7 deg. in robot pitch orientations, for up to 20 deg. needle insertion angles with the TRUS transducer in the horizontal plane when the needle insertion distance was greater than 15 mm

  20. Ultrasound-guided biopsy and drainage

    International Nuclear Information System (INIS)

    Ott, R.C.; Wellauer, J.

    1985-01-01

    This book discusses the ultrasound (US) biopsy techniques, cytology, histology, and physics. The emphasis is on use of US guidance, as the authors find that virtually all lesions are visible at US scanning and they thus save valuable time on the computer tomographic scanner. The authors present in great detail their considerable work in designing needles that are readily visible at US scanning and can also collect good cytologic and histologic material. Biopsy techniques are discussed separately for each organ system. The accuracy of these techniques in over 3,000 of the author's cases is presented

  1. Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Borot de Battisti, Maxence, E-mail: M.E.P.Borot@umcutrecht.nl; Maenhout, Metha; Lagendijk, Jan J. W.; Vulpen, Marco van; Moerland, Marinus A. [Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX (Netherlands); Denis de Senneville, Baudouin [Imaging Division, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX, The Netherlands and IMB, UMR 5251 CNRS/University of Bordeaux, Talence 33400 (France); Hautvast, Gilion; Binnekamp, Dirk [Philips Group Innovation Biomedical Systems, Eindhoven 5656 AE (Netherlands)

    2016-10-15

    Purpose: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image interpretation can be hampered by signal voids arising from blood vessels or calcifications limiting the precision of the needle guidance and reconstruction. In this paper, a new needle tracking prototype is investigated using fiber Bragg gratings (FBG)-based sensing: this prototype involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. This stylet can be inserted into brachytherapy needles and allows a fast measurement of the needle deflection. This study aims to assess the potential of FBG-based sensing for real-time needle (including catheter or tube) tracking during MR-guided intervention. Methods: First, the MR compatibility of FBG-based sensing and its accuracy was evaluated. Different known needle deflections were measured using FBG-based sensing during simultaneous MR-imaging. Then, a needle tracking procedure using FBG-based sensing was proposed. This procedure involved a MR-based calibration of the FBG-based system performed prior to the interventional procedure. The needle tracking system was assessed in an experiment with a moving phantom during MR imaging. The FBG-based system was quantified by comparing the gold-standard shapes, the shape manually segmented on MRI and the FBG-based measurements. Results: The evaluation of the MR compatibility of FBG-based sensing and its accuracy shows that the needle deflection could be measured with an accuracy of 0.27 mm on average. Besides, the FBG-based measurements were comparable to the uncertainty of MR-based measurements estimated at half the voxel size in the MR image. Finally, the mean(standard deviation) Euclidean distance between MR- and FBG-based needle position

  2. The comparative study of CT guided and ultrasound guided percutaneous ethanol injection in the treatment of intra-abdominal cyst

    International Nuclear Information System (INIS)

    Li Heping; Yang Jianyong; Chen Wei; Zhuang Wenquan; Huang Yulian; Chen Jianye

    2005-01-01

    Objective: An comparative study of the interventional approach of CT guided and ultiasound guided percutaneous ethanol injection(PEI) in the treatment of intra-abdominal cyst. Methods: CT guided PEI was performed in the treatment of intra-abdominal cyst in 38 patients while ultrasound guided PEI was performed in 45 cases. Results: The puncture procedure of CT guided PEI was totally performed 83 times in treating 56 intra-abdominal cysts in 38 patients and CT guided PEI was unsuccessful in 6 patients. The puncture procedure of ultrasound guided PEI were performed 87 times in treating 71 intra-abdominal cysts in 55 patients and ultrasound guided PEI only failed only in 1 patient. Conclusion: Ultrasound guided PEI is superior to CT guided PEI in the treatment of intra-abdominal cyst. (authors)

  3. CT-guided spinal injection: initial experience with Sprotte tip needles

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore)

    2010-09-15

    The purpose of this paper is to describe our initial experience and to illustrate the potential benefits of using small caliber (25 and 27 G), noncutting pencil point needles (Sprotte) with single puncture coaxial technique in CT-guided spinal intervention (CTSI). From January 2009 to June 2009, Sprotte needles with single puncture coaxial technique were used in a total of ten patients for selective nerve root block (SNRB), facet joint block, and pars block under CT fluoroscopy (total of 16 target structures). All procedures were performed without conscious sedation, and visual analog scale (VAS) scores were recorded to determine pain related to needle placement. Total CT fluoroscopy time and out-of-plane needle deviation were obtained. Final needle position was documented by contrast injection for SNRBs and image capture for joint space cannulation. Sixteen out of the 16 structures were successfully targeted. No increase in VAS scores associated with needle placement was recorded, after infiltration of local anesthesia. Optimal peri-neurograms were obtained in all cases of SNRB, despite the side-hole opening in the Sprotte needles. Mean CT fluoroscopy time was 2 s (range 2-8 s per structure), and there was no case of out-of-plane needle deviation that required adjustment of the CT gantry. The use of small caliber Sprotte needles in CTSI is technically feasible and represents a potential refinement to current techniques in the management of chronic spinal pain. (orig.)

  4. Guideline for the acquisition and preparation of conventional and endobronchial ultrasound-guided transbronchial needle aspiration specimens for the diagnosis and molecular testing of patients with known or suspected lung cancer

    NARCIS (Netherlands)

    Heijden, E. van der; Casal, R.F.; Trisolini, R.; Steinfort, D.P.; Hwangbo, B.; Nakajima, T.; Guldhammer-Skov, B.; Rossi, G.; Ferretti, M.; Herth, F.F.; Yung, R.; Krasnik, M.

    2014-01-01

    RATIONALE: Conventional transbronchial needle aspiration (TBNA) and endobronchial ultrasound (EBUS)-TBNA are widely accepted tools for the diagnosis and staging of lung cancer and the initial procedure of choice for staging. Obtaining adequate specimens is key to provide a specific histologic and

  5. Examining the sensitivity of ultrasound-guided large core biopsy for invasive breast carcinoma in a population screening programme

    International Nuclear Information System (INIS)

    Rouse, Hannah C.; Ussher, Simon; Cawson, Jennifer N.; Kavanagh, Anne M.

    2013-01-01

    To evaluate the sensitivity of ultrasound-guided core-needle biopsy (UCB) in invasive breast carcinoma and to establish causes of false-negative biopsy in a population screening programme. We identified 571 consecutive women diagnosed with surgically proven invasive breast cancer. Histology from 14-gauge UCB was compared with surgical histology to identify true-positive and false-negative ultrasound core biopsies. True-positive and false-negative groups were compared for tumour size and histology. On blinded review of UCB images and pathology reports from false negative (n=20) and a random sample of true-positive cases (n=80), we compared core sample number and needle visualisation in the lesion. Of 571 carcinomas sampled with UCB, 551 (96.5%) were true positive and 20 (3.5%) were false negative. The mean core number was 2.0 (range 1–3) for false negatives and 2.25 (range 1–4) for true positives (P=0.27). Mean tumour sizes were 13.3 and 16.2mm for the false-negative and true-positive groups, respectively (P=0.25). Tubular carcinomas represented 30% (6/20) of false-negative cases compared with 5.1% (28/551) of the true-positive cases (P<0.001). On blinded review, needle visualisation within the lesion was demonstrated in 47.4% (9/19) of false-negative cases and 76.3% (61/80) of true-positive cases (P=0.02).We demonstrated a sensitivity of 96.5% with a mean of 2.21 cores. False-negative results were more likely in the absence of post-fire needle position verification and with tubular carcinomas. Neither tumour size nor core number predicted diagnostic accuracy.

  6. Utility and safety of endobronchial ultrasound-guided transbronchial needle aspiration in patients with mediastinal and hilar lymphadenopathy: Western region experience.

    Science.gov (United States)

    Aljohaney, Ahmed A

    2018-01-01

    The aim of the study was to evaluate the clinical utility and safety of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in patients with mediastinal and hilar lymphadenopathy and to explicitly describe the utility of this procedure in patient's outcome. A retrospective review and analysis was conducted on 52 patients with mediastinal or hilar lymphadenopathy who underwent EBUS-TBNA from June 2012 to June 2016. All the patients were evaluated by computed tomography (CT) chest with contrast before EBUS examination. Enlarged mediastinal or hilar lymph node was defined as >1 cm short axis on the enhanced CT. Among the 52 patients studied, 57.7% were presented with mediastinal or hilar lymphadenopathy for diagnosis and 42.3% presented with suspected mediastinal malignancy. Paratracheal stations were the most common site for puncture in 33 lymph nodes (43%). The best diagnostic yield was obtained from subcarinal stations and the lowest yield from the hilar stations. Surgical biopsies confirmed lymphoma in six patients, tuberculosis (TB) in three, sarcoidosis in two and one had metastatic adenocarcinoma of unknown primary. The sensitivity, specificity, positive predictive value, and negative predictive value of EBUS-TBNA for diagnosis of mediastinal and hilar lymph node abnormalities were 78.6%, 100%, 100%, and 80%, respectively. The diagnostic yield of EBUS-TBNA in malignant and benign conditions was 79.0%. EBUS-TBNA is a safe and efficacious procedure which can be performed using conscious sedation with high yields. It can be used for the staging of malignancies as well as for the diagnosis of inflammatory and infectious conditions such as sarcoidosis and TB.

  7. Ultrasound guided synovial biopsy of the wrist

    NARCIS (Netherlands)

    van Vugt, R. M.; van Dalen, A.; Bijlsma, J. W.

    1997-01-01

    Seven patients (4 female and 3 male, mean age 46) with arthritis of the wrist (n = 7) without known etiology were evaluated. High-definition ultrasound equipment was used for localization of synovial hypertrophy, suitable for ultrasound guided biopsy without risk. A 18-gauge diameter Tru-cut biopsy

  8. The transabdominal chorionic villus sampling puncture guided by color Doppler ultrasound during early pregnancy

    International Nuclear Information System (INIS)

    Liang Weixiang; Chen Zhiyi; Yuan Wenlin; Cai Kuan; Zhu Junlin; Wang Weiqun; Chen Xia

    2008-01-01

    Objective: To study the operation of chorionic villus sampling (CVS) guided by color Doppler ultrasound (CDU) via abdomen puncture during early pregnancy and investigate the advertences during the operation. Methods: CVS guided by CDU probe via abdomen puncture were operated on 28 pregnant women who had the indications of antenatal diagnosis. CDU was used to observe the implantation position of the fo1iaceous villis and help setting mark of the puncture point and puncture range on body surface before operation. The needle was punctured under real-time ultrasound guidance and villis were aspirated during the operation: The choice of the right time of puncture and the operation skills were emphasized in the study. Results: The CVS puncture approach should be set through CDU ob servation, which attend to avoid the surrounding blood vessels, intestinal canal and surrounding important organs. The puncture point should be chosen in a point where lobif0rmed villis distributed wider and with a larger scope. The operations were performed from 10 to13 weeks of pregnancy, with an average of 11 weeks. Among these 28 cases, 9.6 were successfully drawn materials in one time, 1 in twice and l failure, with the total ratio of achievement was 96.4%. For all the cases, fetal heart pulsating could be seen by real-time CDU observation fight after the operation, and no larger hematoma echo in the placental site occurred. Ultrasound reexamined one week after the operation, fetal heart pulsation could be found in all cases, and no abortion cases occurred after regular follow-up in 25 continued pregnant patients. Conclusion: Abdominal CVS puncture guided by CDU probe is conveniently operated, safe and available in clinic. It is an important method for antenatal diagnosis during early pregnancy. The puncture localization, skills and the time are the key points for the success in obtaining the materials. (authors)

  9. The future perspectives in transrectal prostate ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Sung Il Hwang

    2014-12-01

    Full Text Available Prostate cancer is one of the most common neoplasms in men. Transrectal ultrasound (TRUS-guided systematic biopsy has a crucial role in the diagnosis of prostate cancer. However, it shows limited value with gray-scale ultrasound alone because only a small number of malignancies are visible on TRUS. Recently, new emerging technologies in TRUS-guided prostate biopsy were introduced and showed high potential in the diagnosis of prostate cancer. High echogenicity of ultrasound contrast agent reflect the increased status of angiogenesis in tumor. Molecular imaging for targeting specific biomarker can be also used using ultrasound contrast agent for detecting angiogenesis or surface biomarker of prostate cancer. The combination of TRUS-guided prostate biopsy and ultrasound contrast agents can increase the accuracy of prostate cancer diagnosis. Elastography is an emerging ultrasound technique that can provide the information regarding tissue elasticity and stiffness. Tumors are usually stiffer than the surrounding soft tissue. In two types of elastography techniques, shearwave elastography has many potential in that it can provide quantitative information on tissue elasticity. Multiparametric magnetic resonance imaging (MRI from high resolution morphologic and functional magnetic resonance (MR technique enables to detect more prostate cancers. The combination of functional techniques including apparent diffusion coefficient map from diffusion weighted imaging, dynamic contrast enhanced MR and MR spectroscopy are helpful in the localization of the prostate cancer. MR-ultrasound (US fusion image can enhance the advantages of both two modalities. With MR-US fusion image, targeted biopsy of suspicious areas on MRI is possible and fusion image guided biopsy can provide improved detection rate. In conclusion, with recent advances in multiparametric-MRI, and introduction of new US techniques such as contrast-enhanced US and elastography, TRUS-guided biopsy

  10. Faculty staff-guided versus self-guided ultrasound training for internal medicine residents.

    Science.gov (United States)

    Alba, George A; Kelmenson, Daniel A; Noble, Vicki E; Murray, Alice F; Currier, Paul F

    2013-11-01

    Ultrasonography is of growing importance within internal medicine (IM), but the optimal method of training doctors to use it is uncertain. In this study, the authors provide the first objective comparison of two approaches to training IM residents in ultrasonography. In this randomised trial, a simulation-based ultrasound training curriculum was implemented during IM intern orientation at a tertiary care teaching hospital. All 72 incoming interns attended a lecture and were given access to online modules. Interns were then randomly assigned to a 4-hour faculty-guided (FG) or self-guided (SG) ultrasound training session in a simulation laboratory with both human and manikin models. Interns were asked to self-assess their competence in ultrasonography and underwent an objective structured clinical examination (OSCE) to assess their competence in basic and procedurally oriented ultrasound tasks. The primary outcome was the score on the OSCE. Faculty-guided training was superior to self-guided training based on the OSCE scores. Subjects in the FG training group achieved significantly higher OSCE scores on the two subsets of task completion (0.9-point difference, 95% confidence interval [CI] 0.27-1.54; p = 0.008) and ultrasound image quality (2.43-point difference, 95% CI 1.5-3.36; p training groups demonstrated an increase in self-assessed competence after their respective training sessions and there was little difference between the groups. Subjects rated the FG training group much more favourably than the SG training group. Both FG and SG ultrasound training curricula can improve the self-reported competence of IM interns in ultrasonography. However, FG training was superior to SG training in both skills acquisition and intern preference. Incorporating mandatory ultrasound training into IM residencies can address the perceived need for ultrasound training, improve confidence and procedural skills, and may enhance patient safety. However, the optimal training method

  11. Using virtual-reality simulation to assess performance in endobronchial ultrasound

    DEFF Research Database (Denmark)

    Konge, Lars; Annema, Jouke; Clementsen, Paul

    2013-01-01

    For optimal treatment of patients with non-small cell lung carcinoma, it is essential to have physicians with competence in endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). EBUS training and certification requirements are under discussion and the establishment of basi...

  12. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems

    OpenAIRE

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Background Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA”, which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial...

  13. Computed tomography - guided cutting needle biopsy of pulmonary lesions

    International Nuclear Information System (INIS)

    Liao Shin Yu; Deheinzelin, Daniel; Younes, Riad N.; Chojniak, Rubens

    2002-01-01

    The purpose of this study was to report the experience of a radiology department in the use of computed tomography-guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules. (author)

  14. Nodular fasciitis of the face diagnosed by US-guided core needle biopsy: a case report

    International Nuclear Information System (INIS)

    Lee, Sang Kwon; Kwon, Sun Young

    2006-01-01

    We report here on a case of nodular fasciitis (NF) that was diagnosed by ultrasonography (US)-guided core needle biopsy in a 31-year-old man, and we include the US and computed tomographic (CT) findings and the histopathologic findings at US-guided core needle biopsy (CNB). We suggest that high-resolution US is useful for the detailed evaluation of NF in the superficial regions, such as the face, and US-guided CNB is useful for the definitive histologic diagnosis of NF without causing scarring

  15. Motion compensation for MRI-compatible patient-mounted needle guide device: estimation of targeting accuracy in MRI-guided kidney cryoablations

    Science.gov (United States)

    Tokuda, Junichi; Chauvin, Laurent; Ninni, Brian; Kato, Takahisa; King, Franklin; Tuncali, Kemal; Hata, Nobuhiko

    2018-04-01

    Patient-mounted needle guide devices for percutaneous ablation are vulnerable to patient motion. The objective of this study is to develop and evaluate a software system for an MRI-compatible patient-mounted needle guide device that can adaptively compensate for displacement of the device due to patient motion using a novel image-based automatic device-to-image registration technique. We have developed a software system for an MRI-compatible patient-mounted needle guide device for percutaneous ablation. It features fully-automated image-based device-to-image registration to track the device position, and a device controller to adjust the needle trajectory to compensate for the displacement of the device. We performed: (a) a phantom study using a clinical MR scanner to evaluate registration performance; (b) simulations using intraoperative time-series MR data acquired in 20 clinical cases of MRI-guided renal cryoablations to assess its impact on motion compensation; and (c) a pilot clinical study in three patients to test its feasibility during the clinical procedure. FRE, TRE, and success rate of device-to-image registration were mm, mm, and 98.3% for the phantom images. The simulation study showed that the motion compensation reduced the targeting error for needle placement from 8.2 mm to 5.4 mm (p  <  0.0005) in patients under general anesthesia (GA), and from 14.4 mm to 10.0 mm () in patients under monitored anesthesia care (MAC). The pilot study showed that the software registered the device successfully in a clinical setting. Our simulation study demonstrated that the software system could significantly improve targeting accuracy in patients treated under both MAC and GA. Intraprocedural image-based device-to-image registration was feasible.

  16. Cloned foal derived from in vivo matured horse oocytes aspirated by the short disposable needle system

    OpenAIRE

    Lee, Wonyou; Song, Kilyoung; Lee, Inhyung; Shin, Hyungdo; Lee, Byeong Chun; Yeon, Seongchan; Jang, Goo

    2015-01-01

    Transvaginal ultrasound-guided follicle aspiration is one method of obtaining recipient oocytes for equine somatic cell nuclear transfer (SCNT). This study was conducted: (1) to evaluate the possibility of oocyte aspiration from pre-ovulatory follicles using a short disposable needle system (14-G) by comparing the oocyte recovery rate with that of a long double lumen needle (12-G); (2) to investigate the developmental competence of recovered oocytes after SCNT and embryo transfer. The recover...

  17. Value of fine-needle aspiration biopsy of salivary gland lesions

    DEFF Research Database (Denmark)

    Christensen, Rikke Kølby; Bjørndal, Kristine; Godballe, Christian

    2010-01-01

    BACKGROUND: The aim of this study was to assess the utility of fine-needle aspiration biopsy (FNAB) in the diagnosis and treatment planning of the lesions of the salivary gland. METHODS: Eight hundred seventy-nine aspiration biopsies of the lesion of the salivary gland over a 10-year period, from...... was 98%, and the negative predictive value was 97%. The overall accuracy was 93%. The correct subtyping of the benign lesions was 97%, and the exact type-specific concordance of the malignant lesions was 71%. CONCLUSION: Considerable benefit to the patient may result from the cautious use of FNAB...

  18. Calcific tendinitis of the rotator cuff: a randomized controlled trial of ultrasound-guided needling and lavage versus subacromial corticosteroids.

    Science.gov (United States)

    de Witte, Pieter Bas; Selten, Jasmijn W; Navas, Ana; Nagels, Jochem; Visser, Cornelis P J; Nelissen, Rob G H H; Reijnierse, Monique

    2013-07-01

    Calcific tendinitis of the rotator cuff (RCCT) is frequently diagnosed in patients with shoulder pain, but there is no consensus on its treatment. To compare 2 regularly applied RCCT treatments: ultrasound (US)-guided needling and lavage (barbotage) combined with a US-guided corticosteroid injection in the subacromial bursa (subacromial bursa injection [SAI]) (group 1) versus an isolated SAI (group 2). Randomized controlled trial; Level of evidence, 1. Patients were randomly assigned to the 2 groups. Shoulder function was assessed before treatment and at regular follow-up intervals (6 weeks and 3, 6, and 12 months) using the Constant shoulder score (CS, primary outcome), the Western Ontario Rotator Cuff Index (WORC), and the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH). Additionally, calcification location, size, and Gärtner classification were assessed on radiographs. Results were analyzed using the t test, linear regression, and a mixed model for repeated measures. This study included 48 patients (25 female, 52.1%; mean age, 52.0 ± 7.3 years; 23 patients in group 1) with a mean baseline CS of 68.7 ± 11.9. No patients were lost to follow-up. Four patients in group 1 and 11 in group 2 (P = .06) had an additional barbotage procedure or surgery during the follow-up period because of persisting symptoms and no resorption. At 1-year follow-up, the mean CS in group 1 was 86.0 (95% CI, 80.3-91.6) versus 73.9 (95% CI, 67.7-80.1) in group 2 (P = .005). The mean calcification size decreased by 11.6 ± 6.4 mm in group 1 and 5.1 ± 5.7 mm in group 2 (P = .001). There was total resorption in 13 patients in group 1 and 6 patients in group 2 (P = .07). With regression analyses, correcting for baseline CS and Gärtner type, the mean treatment effect was 20.5 points (P = .05) in favor of barbotage. Follow-up scores were significantly influenced by baseline scores. Results for the DASH and WORC were similar. On average, there was improvement at 1-year follow

  19. Patterns of lymphadenopathy on fine needle aspiration cytology in eastern Nepal

    Directory of Open Access Journals (Sweden)

    N Mainali

    2015-09-01

    Full Text Available BACKGROUND: Lymphadenopathy is a commonly encountered clinical problem. Fine needle aspiration cytology offers the alternative of an immediate, preliminary, although not always specific diagnosis with little trauma and cost, thus providing ample information for further management and reduce the amount of open biopsy.MATERIAL AND METHODS:  FNAC was performed using 21 gauge needle attached with 10ml disposable needle. Slides were prepared, two were air dried and stained with field stain where as two were fixed in ethanol and was stained with PAP stain. One slide was stained with Ziehl-Neelson stain. Field and PAP stained slide were reviewed and diagnosed by Pathologist.RESULT: Out of the 225 patients, reactive lymphadenitis was the most common diagnosis (54.2%, followed by tubercular lymphadenitis (33.44%. Among the age group percentage of tubercular lymphadenitis was more in 210-30 years of age.  Majority of the metastatic carcinoma was in cervical region, comprising mainly squamous cell carcinoma.CONCLUSION: Reactive lymphadenitis was the most common cause of lymphadenopathy especially in case of children. In case of older population, definite pathology for lymph node enlargement was found in most of the cases. Hence FNAC is warranted in lymphadenopathy, as it is simple yet of great diagnostic value.

  20. Fine needle aspiration cytology of dermal cylindroma

    Directory of Open Access Journals (Sweden)

    Parikshaa Gupta

    2014-01-01

    Full Text Available In this paper, we have described fine needle aspiration cytology (FNAC of a rare case of dermal cylindroma. A 40-year-old female presented with a lateral mid-cervical swelling fixed to the skin. FNAC smears showed multiple clusters of small, round to oval cells with hyperchromatic nuclei, inconspicuous nucleoli and scant cytoplasm. In addition, the background showed deposits of basement membrane type material. This was dark magenta colored pinkish globular material. The globules were occasionally surrounded by the basal type of cells. Occasional cells with elongated nuclei were also noted. Cytological diagnosis of skin adnexal tumor possibly cylindroma was offered. Subsequent histopathology of the swelling showed sheets and clusters of cells in a jigsaw puzzle-like fashion. Deposition of abundant basement membrane-like material was noted in between the tumor cells. A diagnosis of cylindorma was offered. FNAC along with the subcutaneous location of the tumor and absence of primary salivary gland tumor may help to diagnose such rare case.

  1. Learning curves for ultrasound guided lung biopsy in the hands of respiratory physicians

    DEFF Research Database (Denmark)

    Laursen, Christian; Naur, Therese Maria Henriette; Bodtger, Uffe

    2016-01-01

    are depicted in figure 1. Six of the physicians had learning curves with a relatively downward or stable projection as a sign of developing competence. Three physicians, however, had learning curves with an upward projection indicating unacceptable competence in performing the procedure......Background: The aim of this study was to determine learning curves for ultrasound guided transthoracic needle biopsies (US-TTNB) performed by respiratory physicians after implementation at three different centers.Methods: During January 2012 to August 2014 patients were included if they had...... a registered US-TTNB procedure at any of the three centers. The US-TTNB was defined as being successful if the result was diagnostic and otherwise as being unsuccessful. Histology or cytology results and clinical follow-up were used as a reference tests. The learning curves for physicians having performed...

  2. CASE REPORT:Chondrosarcoma of Rib on Fine Needle Aspiration Cytology – A Rare Site

    Directory of Open Access Journals (Sweden)

    Prakash M Patil

    2012-07-01

    Full Text Available Background: Fine needle aspiration cytology (FNAC is effective in the diagnosis of bone tumors when combined with careful radiologic and clinical evaluation. Chondrosarcomas often arise in the pelvis or bones of the trunk, but primary chest wall (rib chondrosarcomas are relatively rare. Case Reports: This is a case of a patient with a chondrosarcoma arising in the left lower rib who underwent resection. The patient was a 30-year-old man with a 10x8x6cm tumor in the anterior chest wall of the left side lower rib. On Fine Needle Aspiration Cytology (FNAC of the mass on the anterior chest wall, a diagnosis of a low grade chondrosarcoma was made. This was confirmed histopathologically as a dedifferentiated chondrosarcoma. Macroscopically on excision of gray to pink lobulated mass with adjacent soft tissue and bone with foci of hemorrhage and necrosis the mass measured (M 10x 8x 6 cm. Incidence of chondrosarcoma peaks in the 5th to 6th decade and most commonly involves the femur, humerus, pelvis, and scapula. It rarely involves rib.

  3. Automated Real-Time Needle-Guide Tracking for Fast 3-T MR-guided Transrectal Prostate Biopsy: A Feasibility Study

    NARCIS (Netherlands)

    Zamecnik, P.; Schouten, M.G.; Krafft, A.J.; Maier, F.; Schlemmer, H.-P.; Barentsz, J.O.; Bock, M. de; Futterer, J.J.

    2014-01-01

    Purpose To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation (POCC) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. Materials and Methods This study was approved by the ethics review

  4. Minimally invasive diagnosis of sarcoidosis by EBUS when conventional diagnostics fail

    DEFF Research Database (Denmark)

    Eckardt, J; Olsen, K E; Jørgensen, O D

    2010-01-01

    Endobronchial ultrasound-guided transbronchial fine-needle aspiration (EBUS) is a minimally invasive method used routinely for mediastinal staging of patients with lung cancer. EBUS has also proved to be a valuable diagnostic tool for patients with different intrathoracic lesions who remain...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  6. Testicular fine-needle aspiration for the assessment of intratesticular hormone concentrations

    Directory of Open Access Journals (Sweden)

    Ada P Lee

    2016-01-01

    Full Text Available Measurement of intratesticular sex steroid concentrations in men informs both the development of male hormonal contraceptives and the understanding of male infertility. Given the challenges of using invasive techniques to measure testicular hormone physiology, our group has used a minimally-invasive fine-needle aspiration technique to measure intratesticular hormones in normal healthy men. Herein, we present a post-hoc analysis of the safety and efficacy of testicular fine-needle aspiration (FNA completed as part of six clinical trials. From 2001 through 2011, a total of 404 procedures were conducted among 163 research volunteers, 85.9% of which were successful in obtaining sufficient fluid for the measurement of intratesticular steroid concentrations. Pain was the most common side effect, with 36.8% of procedures associated with moderate procedural pain and 4.7% with severe procedural pain. Postprocedural pain was uncommon and abated within a few days. Mild local bruising occurred with 14.9% of procedures. Two serious adverse events (0.5% required surgical intervention. The risk of an adverse event was not associated with age, body mass index, testicular size, or the volume of fluid aspirated. Testicular FNA to obtain fluid for measurement of intratesticular steroid concentrations frequently causes mild to moderate procedural pain, but serious adverse events occur rarely. Testicular FNA has been instrumental for defining human intratesticular hormone physiology and is a minimally-invasive, safe, effective method for obtaining fluid for research on testicular physiology and pathology.

  7. An ultra-high field strength MR image-guided robotic needle delivery system for in-bore small animal interventions.

    Science.gov (United States)

    Gravett, Matthew; Cepek, Jeremy; Fenster, Aaron

    2017-11-01

    The purpose of this study was to develop and validate an image-guided robotic needle delivery system for accurate and repeatable needle targeting procedures in mouse brains inside the 12 cm inner diameter gradient coil insert of a 9.4 T MR scanner. Many preclinical research techniques require the use of accurate needle deliveries to soft tissues, including brain tissue. Soft tissues are optimally visualized in MR images, which offer high-soft tissue contrast, as well as a range of unique imaging techniques, including functional, spectroscopy and thermal imaging, however, there are currently no solutions for delivering needles to small animal brains inside the bore of an ultra-high field MR scanner. This paper describes the mechatronic design, evaluation of MR compatibility, registration technique, mechanical calibration, the quantitative validation of the in-bore image-guided needle targeting accuracy and repeatability, and demonstrated the system's ability to deliver needles in situ. Our six degree-of-freedom, MR compatible, mechatronic system was designed to fit inside the bore of a 9.4 T MR scanner and is actuated using a combination of piezoelectric and hydraulic mechanisms. The MR compatibility and targeting accuracy of the needle delivery system are evaluated to ensure that the system is precisely calibrated to perform the needle targeting procedures. A semi-automated image registration is performed to link the robot coordinates to the MR coordinate system. Soft tissue targets can be accurately localized in MR images, followed by automatic alignment of the needle trajectory to the target. Intra-procedure visualization of the needle target location and the needle were confirmed through MR images after needle insertion. The effects of geometric distortions and signal noise were found to be below threshold that would have an impact on the accuracy of the system. The system was found to have negligible effect on the MR image signal noise and geometric distortion

  8. Comparison of ultrasound-guided versus anatomical landmark ...

    African Journals Online (AJOL)

    Background Femoral vein cannulation may be required during major surgery in infants and children and may prove to be life saving under certain conditions. This study compared ultrasound (US)-guided cannulation of the femoral vein in infants with the traditional anatomical landmark-guided technique. Methods Eighty ...

  9. Diagnosis of sclerosing hemangioma of lung: Don′t rely on fine-needle aspiration cytology diagnosis alone

    Directory of Open Access Journals (Sweden)

    Kaushik Saha

    2013-01-01

    Full Text Available Sclerosing hemangioma is a rare variety of benign pulmonary neoplasm. It usually presents as asymptomatic, solitary, peripheral, circumscribed lesions in middle-aged women. Here, we describe a 46-year-old woman presenting to us for evaluation of right parahilar lung mass. Previous chest radiography done 10 years back showed a lung mass of almost similar size. Computed Tomography (CT-guided fine-needle aspiration cytology (FNAC was suggestive of adenocarcinoma of lung. A well-circumscribed, capsulated, ovoid mass measuring 5.6 cm × 4 cm × 3 cm, adjacent to the transverse fissure of the right lung was excised by lateral thoracotomy. Histopathological examination along with immunohistochemistry was suggestive of sclerosing hemangioma of lung. A pathologist must consider the clinicoradiological features before coming to a final diagnosis of lung malignancy from FNAC. Whenever there is any confusion regarding lung mass, thoracotomy must be done for arriving at an exact diagnosis from histopathology.

  10. Vacuum mammotomy under ultrasound guidance

    International Nuclear Information System (INIS)

    Luczynska, E.; Kocurek, A.; Pawlik, T.; Aniol, J.; Herman, K.; Skotnicki, P.

    2007-01-01

    Breast ultrasound is a non-invasive method of breast examination. You can use it also for fine needle biopsy, core needle biopsy, vacuum mammotomy and for placing the '' wire '' before open surgical biopsy. 106 patients (105 women and 1 man) aged 20-71 years (mean age 46.9) were treated in Cancer Institute in Cracow by vacuum mammotomy under ultrasound guidance. The lesions found in ultrasonography were divided into three groups: benign lesions (BI RADS II), ambiguous lesions (BI RADS 0, III and IVa), and suspicious lesions (BI RADS IV B, IV C and V). Then lesions were qualified to vacuum mammotomy. According to USG, fibroadenoma or '' fibroadenoma-like '' lesions were found in 75 women, in 6 women complicated cysts, in 6 women cyst with dense fluid (to differentiate with FA), and in 19 patients undefined lesions. Fibroadenoma was confirmed in histopathology in 74% patients among patients with fibroadenoma or '' fibroadenoma-like '' lesions in ultrasound (in others also benign lesions were found). Among lesions undefined after ultrasound examination (total 27 patients) cancer was confirmed in 6 % (DCIS and IDC). In 6 patients with complicated cysts in ultrasound examination, histopathology confirmed fibroadenoma in 4 women, an intraductal lesion in 1 woman and inflamatory process in 1 woman. Also in 6 women with a dense cyst or fibroadenoma seen in ultrasound, histopathology confirmed fibroadenoma in 3 women and fibrosclerosis in 3 women. Any breast lesions undefined or suspicious after ultrasound examination should be verified. The method of verification or kind of operation of the whole lesion (vacuum mammotomy or '' wire '') depends on many factors, for example: lesion localization; lesion size; BI RADS category. (author)

  11. Comparison of needles size in pediatric renal biopsy with sono-guided percutaneous-automated gun technique

    International Nuclear Information System (INIS)

    Kim, Jong Chul; Park, Jin Yong

    1997-01-01

    To compare the efficacy of a 20-gauge and an 18-gauge needle in sono-guided percutaneous automated gun biopsy for establishing the specific diagnosis of renal parenchymal disease in pediatric kidneys. In 60 pediatric patients with renal parenchymal diseases, percutaneous sono-guided gun biopsy was performed by an experienced radiologist. In two groups of 30 patients, regardless of their age, two needle passes were performed, using alternately an 18-gauge or a 20-gauge biopsy needle. The core of renal tissue thus obtained was examined with light, immunofluorescent or electron microscopy by the renal pathologist. The mean number of intact glomeruli of whole tissue core per biopsy, as seen on the light microscopy, and post-bioptic complications were compared between the two different needle size groups. The number (mean±1 standard deviation) of glomeruli obtained per biopsy was 17±8 in the 18-gauge needle group, and 14±5 in the 20-gauge group. Between two groups, there was no major post-bioptic complication requiring specific treatment, nor a statistically significant difference in the frequency of minor complications. Even though more glomeruli were obtained with an 18-gauge needle, the number obtained with a 20-gauge needle also permitted adequate pathologic examination. Both an 18-gauge and a 20-gauge needle may thus be suitable for renal biopsy in pediatric patients

  12. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  13. Ultrasound-Guided Percutaneous Electrolysis and Eccentric Exercises for Subacromial Pain Syndrome: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    José L. Arias-Buría

    2015-01-01

    Full Text Available Objective. To compare effects of ultrasound- (US- guided percutaneous electrolysis combined with an eccentric exercise program of the rotator cuff muscles in subacromial pain syndrome. Methods. Thirty-six patients were randomized and assigned into US-guided percutaneous electrolysis (n=17 group or exercise (n=19 group. Patients were asked to perform an eccentric exercise program of the rotator cuff muscles twice every day for 4 weeks. Participants assigned to US-guided percutaneous electrolysis group also received the application of galvanic current through acupuncture needle on each session once a week (total 4 sessions. Shoulder pain (NPRS and disability (DASH were assessed at baseline, after 2 sessions, and 1 week after the last session. Results. The ANOVA revealed significant Group∗Time interactions for shoulder pain and disability (all, P<0.01: individuals receiving US-guided percutaneous electrolysis combined with the eccentric exercises experienced greater improvement than those receiving eccentric exercise alone. Conclusions. US-guided percutaneous electrolysis combined with eccentric exercises resulted in small better outcomes at short term compared to when only eccentric exercises were applied in subacromial pain syndrome. The effect was statistically and clinically significant for shoulder pain but below minimal clinical difference for function. Future studies should investigate the long-term effects and potential placebo effect of this intervention.

  14. Feasibility of ultrasound-guided intraarticular contrast injection for MR arthrography

    International Nuclear Information System (INIS)

    Baek, Soo Jin; Lee, Jong Min; Kang, Duck Sick

    2005-01-01

    To assess the feasibility of ultrasound-guided intraarticular contrast injection using the posterior approach for MR arthrography. Between June 2002 and October 2004, 132 patients (29 female, 103 male: mean age, 33.6 years) underwent ultrasound-guided intraarticular contrast media injection (40 ml saline + 10 ml 2% lidocaine + 0.2 ml gadopentetate dimeglumine + 0.4 ml epinephrine) for MR arthrography. The patients were classified into four groups, viz. the no leakage group, the minor leakage with successful intraarticular injection group, the major leakage with unsuccessful intraarticular injection group, and the injection failure group. The 'no leakage' and 'minor leakage' groups were considered to be technical successes, while the 'major leakage' and 'injection failure' groups were regarded as technical failures. The technical success rate of ultrasound-guided intraarticular contrast injection using the posterior approach for MR Arthrography was 99.2% (131/132 patients) and one patients 0.7% (1/132 patients) was included in the 'major leakage' group. Ultrasound-guided intraarticular contrast injection using the posterior approach for MR arthrography was feasible with a high success rate

  15. EFFECTIVENESS OF SALVAGE SELECTIVE AND MODIFIED RADICAL NECK DISSECTION FOR REGIONAL PATHOLOGIC LYMPHADENOPATHY AFTER CHEMORADIATION

    NARCIS (Netherlands)

    van der Putten, Lisa; van den Broek, Guido B.; de Bree, Remco; van den Brekel, Michiel W. M.; Balm, Alfons J. M.; Hoebers, Frank J. P.; Doornaert, Patricia; Leemans, C. René; Rasch, Coen R. N.

    2009-01-01

    Background. The objective of this study was to evaluate the effectiveness and safety of our careful observational strategy and neck dissections and the accuracy of ultrasound-guided fine-needle aspiration cytology, and to determine the prognostic factors for outcome and regional control after

  16. CT-guided procedures: evaluation of a phantom system to teach accurate needle placement

    International Nuclear Information System (INIS)

    Dimmick, S.; Jones, M.; Challen, J.; Iedema, J.; Wattuhewa, U.; Coucher, J.

    2007-01-01

    Aim: To evaluate the use of a phantom system to help teach the basic techniques of accurate CT-guided needle placement, thereby avoiding the risks associated with teaching on patients. Materials and Methods: Gelatine phantoms with five, 1.9 cm embedded spherical wooden targets were constructed. Four trainee operators performed 15 simulated biopsy procedures on the targets (series one) and repeated identical procedures 2 weeks later (series two). Statistical analysis of accuracy of needle placement and subject confidence were performed. Results: Significant sequential improvement in axial plane angular error was noted with the average error decreasing by 0.33 degrees after every five procedures performed (95% CI: -0.58 to -0.08, p = 0.01). Operator confidence indicated significant improvement both within each series and from series one to series two (95% CI: 0.08 to 1.17, p = 0.025 and 95% CI: 0.00 to 0.58, p = 0.05) respectively. However, variability in operator performance made statistically significant improvement in other variables unproven. Conclusion: Despite the study comprising a relatively small number of participants and procedures, it clearly demonstrated the effectiveness of teaching operators to perform CT-guided procedures using a phantom system. Needle placement accuracy significantly improved, with a reduction in axial angular error, and improved operator confidence without the risks associated with training on patients. Three of the operators in this study had never performed a CT-guided procedure previously, and their proficiency, after a relatively short but intense period of training, was impressive. The use of phantoms should be considered routinely for basic training of CT-guided needle placement

  17. Microwave ablation of liver metastases guided by contrast-enhanced ultrasound

    DEFF Research Database (Denmark)

    Lorentzen, T; Skjoldbye, B O; Nolsoe, C P

    2011-01-01

    The aim of our study was to evaluate the efficacy of microwave (MW) ablation of liver metastases guided by B-mode ultrasound (US) and contrast-enhanced US (CEUS).......The aim of our study was to evaluate the efficacy of microwave (MW) ablation of liver metastases guided by B-mode ultrasound (US) and contrast-enhanced US (CEUS)....

  18. Usefulness of normal saline for sealing the needle track after CT-guided lung biopsy

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2015-01-01

    Aim: To determine whether the use of normal saline for sealing the needle track can reduce the incidence of pneumothorax and chest tube placement after computed tomography (CT)-guided lung biopsy. Materials and methods: A prospective, randomised, controlled trial enrolling 322 patients was conducted. All patients were randomly assigned to one of two groups: those in whom the needle track was not sealed with normal saline (n=161, Group A) and those who did receive normal saline (n=161, Group B). CT-guided biopsy was performed with coaxial technique. Normal saline, which ranged from 1–3 ml, was injected while the trocar needle was being withdrawn. Patient characteristics, lesion, and procedure variables were analysed as potential risk variables for occurrence of pneumothorax and chest tube placement. Results: The incidence of pneumothorax was 26.1% in Group A and 6.2% in Group B (p<0.001). Nine patients in Group A and one patient in Group B required chest tube placement (p=0.010). Using multiple logistic regression analysis, smaller lesion size, greater needle–pleural angle, longer lesion–pleural distance, presence of emphysema, and no sealing the needle track with normal saline were significantly associated with an increased risk of pneumothorax, and that the latter three factors were also associated with an increased risk of pneumothorax requiring chest tube placement. Conlusion: Normal saline for sealing the needle track significantly reduces the incidence of pneumothorax and prevents subsequent chest tube placement after CT-guided lung biopsy. - Highlights: • Normal saline is an effective sealant for use in lung biopsy. • This technique reduced the incidence of pneumothorax and chest tube placement. • This technique should be recommended for CT-guided lung biopsy.

  19. EFSUMB Guidelines on Interventional Ultrasound (INVUS), Part IV - EUS-guided interventions

    DEFF Research Database (Denmark)

    Jenssen, C; Hocke, M; Fusaroli, P

    2016-01-01

    The fourth part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound describes general aspects of endoscopic ultrasound-guided diagnostic and therapeutic interventions and assesses the evidence for endoscopic ultrasound-gu...

  20. Role of Duplex Power Doppler Ultrasound in Differentiation between Malignant and Benign Thyroid Nodules

    International Nuclear Information System (INIS)

    Algin, Oktay; Algin, Efnan; Gokalp, Gokhan; Ocakog, Gokhan; Erdog an, Cuneyt; Saraydaroglu, Ozlem; Ercan Tuncel, Prof

    2010-01-01

    To evaluate the usage of duplex power Doppler ultrasound (PDUS) for the differentiation of benign and malignant thyroid nodules. We prospectively examined 77 thyroid nodules in 60 patients undergoing ultrasound-guided fine needle aspiration biopsy (FNAB). Each nodule was described according to size, inner structure, borders, parenchymal echogenicity, peripheral halo formation, and the presence of calcification (Bmode ultrasound findings). Vascularity as determined by PDUS imaging was defined as non-vascular, peripheral, central, or of mixed type. For each nodule, the pulsatility index (PI) and resistive index (RI) values were obtained. Results of FNAB and surgical pathological examination (if available) were used as a proof of final diagnosis to categorize all nodules as benign or malignant. A receiver operating characteristic (ROC) curve analysis was performed to establish cut-off, sensitivity, and specificity values associated with RI-PI values. A significant relationship was observed between malignancy and irregular margins, microcalcifications, and hypoechogenicity on ultrasound examination (p 0.05). The central, peripheral, and mean RI-PI values were higher in malignant nodules when compared to the other cytologies (p < 0.05). Vascularity is not a useful parameter for distinguishing malignant from benign thyroid nodules. However, RI and PI values are useful in distinguishing malignant from benign thyroid nodules

  1. Histopathological correlation of a group of suspicious breast lesions of malignancy valued by ultrasound categorized by BIRADS classification, to which were realized core needle biopsy through sonographic guide, at the Servicio de Radiologia e Imagenes Medicas of the Hospital Mexico, in the period from January to December 2012

    International Nuclear Information System (INIS)

    Castro Escalante, Ruben; Salazar Blanco, Esteban

    2014-01-01

    A histological correlation is established through a transversal study of a group of suspected breast lesions of malignancy valued by ultrasound. Injuries were categorized by BIRADS system and subjected to ultrasound-guided core needle biopsy, at the Servicio de Radiologia e Imagenes Medicas of the Hospital Mexico, from January to December 2012, in order to establish casuistic and comparison with studies of other latitudes. The 99 cases analyzed have complied with inclusion criteria, where the variables have been: the age of the patient, the type of injury, laterality and location of the lesion, the sonographic characteristics of the injury, BIRADS of the lesion, the professional who has performed the biopsy, the number and quality of the sample and histological diagnostic of the injury. The results of the study have found that the average age has been 53.2 years and the group of 40-69 years has had more cases of breast lesions, the highest percentage of lesions were biopsied by an assistant or resident with residents with your assistant, left laterality has predominated (p<0.05), the upper outer quadrant has been the most frequent, the solid nodule of regular borders of 1,2 cm of diameter has predominated in the study, 4 samples per lesion have been the most frequent, the adequate quality of the sample has been of the 95%, BIRADS IVA lesions have predominated, malignant lesion most frequent has been the N2 infiltrating ductal carcinoma and the benign has been the fibroadenoma. The guidelines established by BIRADS system have achieved better handling and behavior of breast lesions, as well as adhere to the techniques described of the procedure of ultrasound-guided core needle biopsy. This last procedure has been minimally invasive of high precision, according to the results obtained of the study. (author) [es

  2. Role of AgNORs in thyroid lesions on fine needle aspiration cytology smears

    Directory of Open Access Journals (Sweden)

    Asotra Sarita

    2008-01-01

    Full Text Available Background: Fine needle aspiration has an important role in diagnosis of thyroid neoplasm. However, it is difficult to differentiate between follicular adenoma and follicular carcinoma by cytology alone. Recently, silver staining has been performed for nucleolar organizer regions (AgNORs to differentiate various tumors. Aims: The present study was undertaken to see if the AgNOR technique could distinguish between benign and malignant lesions, particularly, follicular neoplasm. Materials and Methods: One hundred forty cases of thyroid lesions were examined, which included colloid goiter (n = 36, multinodular goiter (n = 38, subacute thyroiditis (n = 6, Hashimoto′s thyroiditis (n = 17, lymphocytic thyroiditis (n = 3, follicular neoplasm (n = 18, Hurthle cell neoplasm (n = 3, papillary carcinoma (n = 16, and medullary carcinoma (n = 3. Diagnosis was confirmed by histopathology in 80 cases. The usual one-step silver colloidal reaction was performed at room temperature for 35 minutes and intranuclear dots of silver deposits were counted in 100 cells. Results: AgNOR counts of benign and malignant lesions were compared and were found to be statistically significant (P < 0.001. The mean AgNOR counts were higher in neoplastic lesions. Conclusions: AgNOR counting in fine needle aspiration smears is a simple, sensitive, and cost-effective method for differentiating benign from malignant thyroid follicular neoplasms.

  3. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    International Nuclear Information System (INIS)

    Cornelis, F.; Takaki, H.; Laskhmanan, M.; Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G.

    2015-01-01

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy

  4. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    Energy Technology Data Exchange (ETDEWEB)

    Cornelis, F.; Takaki, H. [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States); Laskhmanan, M. [Perfint Healthcare Inc (India); Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G., E-mail: srimaths@mskcc.org [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States)

    2015-10-15

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.

  5. Percutaneous ultrasound-guided renal biopsy: A Libyan experience

    Science.gov (United States)

    Mishra, A.; Tarsin, R.; ElHabbash, B.; Zagan, N.; Markus, R.; Drebeka, S.; AbdElmola, K.; Shawish, T.; Shebani, A.; AbdElmola, T.; ElUsta, A.; Ehtuish, E. F.

    2010-01-01

    This study was done to assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy (PRB), to ascertain the risk factors for complications and determine the optimal period of observation. The radiologist (A.M.) at the National Organ Transplant Centre, Central Hospital, Tripoli, Libya, performed 86 PRBs between February 1, 2006, and January 31, 2008, using an automated biopsy gun with 16-gauge needle. Coagulation profile was done in all the patients. All patients were kept on strict bed rest for six hours post-procedure. Eighty six renal biopsies were performed on 78 patients referred from rheumatology department and eight post-kidney transplant recipients; 23 were males with age range 15 – 56 years and 63 females with age range 16 – 66 years. A mean of 17.5 glomeruli were present in each specimen. A glomerular yield of less than five glomeruli was seen in four biopsies. Class I lupus nephritis (LN) was seen in 1 patient, class II lupus nephritis in 7 patients, class III LN in 13 patients and class IV LN in 29 patients. All the eight renal allografts were diagnosed as acute tubular necrosis or acute interstitial rejection. The risk of post-biopsy bleeding was higher in women, older patients and higher PTT. The overall complication rate was 5.8%. Three complications were observed within six hours of biopsy. No late complication was seen. PRB under real-time ultrasound-guidance is a safe and efficacious procedure to establish the histological diagnosis and should be done as out-patient procedure. Observation time of six hours post-biopsy is optimal. PMID:20835320

  6. A convenient tool for gas derivatization using fine-needle capillary mounting for protein crystals

    International Nuclear Information System (INIS)

    Mizuno, Nobuhiro; Makino, Masatomo; Kumasaka, Takashi

    2013-01-01

    A convenient gas-derivatization tool for protein crystals is presented in combination with a fine-needle capillary and a gas-pressure regulator. Gas derivatization of protein crystals is useful not only to analyse gas-binding proteins but also to solve the phase problem of X-ray crystallography by using noble gases. However, the gas pressurization tools for these experiments are often elaborate and need to release the gas before flash-cooling. To simplify this step, a procedure using a fine-needle capillary to mount and flash-cool protein crystals under the pressurization of gases has been developed. After the crystals are picked up with the capillary, the capillary is sealed with an adhesive and then connected directly to a gas regulator. The quality of the diffraction data using this method is comparable with that of data from conventional pressurization procedures. The preparation of xenon-derivatives of hen egg-white lysozyme using this method was a success. In the derivatives, two new xenon binding sites were found and one of their sites vanished by releasing the gas. This observation shows the availability of flash-cooling under gas pressurization. This procedure is simple and useful for preparing gas-derivative crystals

  7. Comparison of ultrasound and ultrasound plus nerve stimulator guidance axillary plexus block

    International Nuclear Information System (INIS)

    Demirelli, G.; Baskan, S.; Karabeyoglu, I.; Aytac, I.; Omek, D.H.; Erdogmus, A.; Baydar, M.

    2017-01-01

    To evaluate the characteristics of axillary plexus blockade applied using ultrasound only and using ultrasound together with nerve stimulator in patients undergoing planned forearm, wrist or hand surgery. Methods: This randomised, prospective, double-blinded, single-centre study was conducted at Ankara Numune Training and Research Hospital, Ankara, Turkey, from November 2014 to August 2015, and comprised patients undergoing forearm, wrist or hand surgery. Participants were separated into 2 groups. In Group 1, the nerve roots required for the surgical site were located one by one and local anaesthetic was applied separately to each nerve for the block. In Group 2, the vascular nerve bundle was located under ultrasound guidance and a total block was achieved by administering all the local anaesthetic within the nerve sheath. In the operating room, standard monitorisation was applied. Following preparation of the skin, the axillary region nerve roots and branches and vascular structures were observed by examination with a high-frequency ultrasound probe. In both groups, a 22-gauge, 5cm block needle was entered to the axillary region with visualisation of the whole needle on ultrasound and 20ml local anaesthetic of 0.5% bupivacaine was injected. SPSS 19 was used for data analysis. Results: Of the 60 participants, there were 30(50%) in each group. The mean age was 39.1+-15 years in the group 1 which was the ultrasound nerve stimulation group, and 41.5+-14.3 years in group 2. The duration of the procedure was longer in group I than in group 2 (p<0.05). Patient satisfaction values during the procedure were higher in group 2(p<0.05). In the ulnar sensory examination, the values of the patients in group 1 were higher at 10, 15, 20 and 25 minutes (p<0.05). In the median, radial and ulnar motor examination, the values of the patients in group 1were higher at 15 and 20 minutes (p<0.05). Conclusion: Brachial plexus blockade via axillary approach guided by ultrasound offered

  8. Endoscopic Ultrasound-Guided Biliary Drainage

    International Nuclear Information System (INIS)

    Artifon, Everson L.A.; Ferreira, Fla'vio C.; Sakai, Paulo

    2012-01-01

    To demonstrate a comprehensive review of published articles regarding endoscopic ultrasound (EUS)-guided biliary drainage. Review of studies regarding EUS-guided biliary drainage including case reports, case series and previous reviews. EUS-guided hepaticogastrostomy, coledochoduodenostomy and choledoantrostomy are advanced biliary and pancreatic endoscopy procedures, and together make up the echo-guided biliary drainage. Hepaticogastrostomy is indicated in cases of hilar obstruction, while the procedure of choice is the coledochoduodenostomy or choledochoantrostomy in distal lesions. Both procedures must be performed only after unsuccessful ERCPs. The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. Hepaticogastrostomy and coledochoduodenostomy or choledochoantrostomy are feasible when performed by endoscopists with expertise in biliopancreatic endoscopy. Advanced echo-endoscopy should currently be performed under a rigorous protocol in educational institutions.

  9. Endoscopic Ultrasound-Guided Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Artifon, Everson L.A.; Ferreira, Fla& #x27; vio C.; Sakai, Paulo [University of Saeo Paulo, Saeo Paulo (Brazil)

    2012-02-15

    To demonstrate a comprehensive review of published articles regarding endoscopic ultrasound (EUS)-guided biliary drainage. Review of studies regarding EUS-guided biliary drainage including case reports, case series and previous reviews. EUS-guided hepaticogastrostomy, coledochoduodenostomy and choledoantrostomy are advanced biliary and pancreatic endoscopy procedures, and together make up the echo-guided biliary drainage. Hepaticogastrostomy is indicated in cases of hilar obstruction, while the procedure of choice is the coledochoduodenostomy or choledochoantrostomy in distal lesions. Both procedures must be performed only after unsuccessful ERCPs. The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. Hepaticogastrostomy and coledochoduodenostomy or choledochoantrostomy are feasible when performed by endoscopists with expertise in biliopancreatic endoscopy. Advanced echo-endoscopy should currently be performed under a rigorous protocol in educational institutions.

  10. Fine needle aspiration biopsy diagnosis of metastatic neoplasms of the breast. A three-case report

    Directory of Open Access Journals (Sweden)

    Raquel Garza-Guajardo

    2005-09-01

    Full Text Available Abstract Metastases to the breast are unusual lesions that make up approximately 2% of all malignant mammary neoplasms and may mimic both benign and malignant primary neoplasms from a clinical point of view, as well as in imaging studies. Arriving at a correct diagnosis is therefore essential in order to establish appropriate management. We present three cases of metastatic neoplasms diagnosed through fine needle aspiration biopsy and immunocytochemistry. The cytological diagnoses were: medulloblastoma in an 18-year-old woman, melanoma in a 26-year-old man, and an exceptional case of ovarian sarcoma originating from a granulosa cell tumor with metastases to both breasts. A metastatic disease should be considered in the differential diagnosis of a palpable mass in the breast, especially if there is a history of an extramammary malignant neoplasm. Fine needle aspiration biopsy is the method of choice for the management of these cases. Whenever possible the exam of the material obtained should be compared to the previous biopsy, which is usually enough to arrive at a correct diagnosis, thus preventing unnecessary surgical procedures.

  11. Image-guided fine needle cytology with aspiration versus non-aspiration in retroperitoneal masses: is aspiration necessary?

    Science.gov (United States)

    Misra, Rajiv Kumar; Mitra, Shaila; Jain, Rishav Kumar; Vahikar, Shilpa; Bundela, Archana; Misra, Purak

    2015-03-01

    Although using fine needle cytology with aspiration (FNC-A) for establishing diagnoses in the retroperitoneal region has shown promise, there is scant literature supporting a role of non-aspiration cytology (FNC-NA) for this region. We assessed the accuracy and reliability of FNC-A and FNC-NA as tools for preoperative diagnosis of retroperitoneal masses and compared the results of both techniques with each other and with histopathology. Fifty-seven patients with retroperitoneal masses were subjected to FNC-A and FNC-NA. Smears were stained with May-Grunwald Giemsa and hematoxylin and eosin stain. An individual slide was objectively analysed using a point scoring system to enable comparison between FNC-A and FNC-NA. By FNC-A, 91.7% accuracy was obtained in cases of retroperitoneal lymph node lesions followed by renal masses (83.3%). The diagnostic accuracy of other sites by FNC-A varied from 75.0%-81.9%. By FNC-NA, 93.4% diagnostically accurate results were obtained in the kidney, followed by 75.0% in adrenal masses. The diagnostic accuracy of other sites by FNC-NA varied from 66.7%-72.8%. Although both techniques have their own advantages and disadvantages, FNC-NA may be a more efficient adjuvant method of sampling in retroperitoneal lesions.

  12. Automated tru-cut imaging-guided core needle biopsy of canine ...

    African Journals Online (AJOL)

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single ...

  13. Solitary thyroid metastasis from colon cancer: fine-needle aspiration cytology and molecular biology approach.

    Science.gov (United States)

    Onorati, M; Uboldi, P; Bianchi, C L; Nicola, M; Corradini, G M; Veronese, S; Fascì, A I; Di Nuovo, F

    2015-01-01

    Thyroid gland is one of the most vascularized organs of the body, nevertheless clinical and surgical series report an incidence of secondary malignancies in this gland of only 3%. Colorectal carcinoma metastatic to the thyroid gland is not as uncommon as previously believed, infact the number of cases seems to be increased in recent years due to the more frequent use of fine-needle aspiration cytology (FNAC) guided by ultrasonography. Although kidney, breast and lung metastases to the thyroid are frequent, metastasis from colon cancer is clinically rare with 52 cases reported in the literature in the last 5 decades and three cases described as solitary thyroid metastasis from the colon cancer without any other visceral metastases. To the best of our knowledge, we report the fourth case of solitary, asymptomatic thyroid metastasis from colon cancer without involvement of other organs. We discuss the importance of FNAC to detect metastatazing process as a compulsory step of the diagnostic and therapeutic management algorithm, combined with a molecular biology approach. A review of the last 5 decades literature, to update the number of cases described to date, is also included.

  14. Ultrasound-guided drainage of subcutaneous abscesses on the trunk is feasible

    DEFF Research Database (Denmark)

    Kjær, Søren; Rud, Bo; Bay-Nielsen, Morten

    2013-01-01

    Subcutaneous trunk abscesses are frequent, and current treatment options generally involve incision. By contrast, the standard care for breast abcesses is ultrasound-guided drainage. The aim of this study was to evaluate the feasibility of ultrasound-guided drainage combined with antibiotics...... in the treatment of subcutaneous abscesses on the trunk....

  15. Medial approach of ultrasound-guided costoclavicular plexus block and its effects on regional perfussion.

    Science.gov (United States)

    Nieuwveld, D; Mojica, V; Herrera, A E; Pomés, J; Prats, A; Sala-Blanch, X

    2017-04-01

    Ultrasound-guided infraclavicular block in the costoclavicular space located between the clavicle and the first rib, reaches the secondary trunks when they are clustered together and lateral to the axillary artery. This block is most often performed through a lateral approach, the difficulty being finding the coracoid process an obstacle and guiding the needle towards the vessels and pleura. A medial approach, meaning from inside to outside, will avoid these structures. Traditionally the assessment of a successful block is through motor or sensitive responses but a sympathetic fibre block can also be evaluated measuring the changes in humeral artery blood flow, skin temperature and/or perfusion index. To describe the medial approach of the ultrasound-guided costoclavicular block evaluating its development by motor and sensitive response and measurement of sympathetic changes. Description of the technique and administration of 20ml of contrast in a fresh cadaver model, evaluating the distribution with CT-scan and sagittal sections of the anatomic piece. Subsequently in a clinical phase, including 11 patients, we evaluated the establishment of motor, sensitive and sympathetic blocks. We evaluated the sympathetic changes reflected by humeral artery blood flow, skin temperature and distal perfusion index. In the anatomical model the block was conducted without difficulties, showing an adequate periclavicular distribution of the contrast in the CT-scan and in sagittal sections, reaching the interscalenic space as far as the secondary trunks. Successful blocks were observed in 91% of patients after 25minutes. All the parameters reflecting sympathetic block increased significantly. The humeral artery blood flow showed an increase from 108 ± 86 to 188±141ml/min (P=.05), skin temperature from 32.1±2 to 32.8±9°C (P=.03) and perfusion index from 4±3 to 9±5 (P=.003). The medial approach of the ultrasound-guided costoclavicular block is anatomically feasible, with high

  16. Needle stick injuries during fine needle aspiration procedure: Frequency, causes and knowledge, attitude and practices of cytopathologists

    Directory of Open Access Journals (Sweden)

    Neeta Kumar

    2011-01-01

    Full Text Available Background: There is no study available on the frequency, predisposing factors and outcome of needle stick injury (NSI in cytopathologists who perform fine needle aspiration (FNA. Aim: To know the frequency, circumstances and sequlae of NSI sustained by cytopathologists, assess their knowledge about risks of NSI and attitudes and practices towards use of standard precautions and post-injury wound care. Materials and Methods: Study design: cross sectional. Setting: Tertiary care teaching and non-teaching hospitals and private laboratories. Data collection method: Knowledge, attitude and practices survey using a questionnaire. Results: Majority (90.5% of the respondents have had NSI in their total career. In the previous year, more than half (71.4% had at least one NSI (mean 3.2. NSI was the most common in index finger of non-dominant hand (59.6% and occurred during step two of FNA procedure when the needle was being manipulated within the lump. The major predisposing factors were uncooperative patients (88.9%, small children (54%, deep masses (36.5%, hot humid climate (88.9%, heavy workload (76.2% and poor administrative arrangement (54%. The adherence to standard precautions was not optimal (74.6%. None of them reported NSI to the authorities, nor investigated source patient or themselves. 82.5% of the respondents were not aware of any formal exposure reporting system in their hospital. Conclusion: Cytopathologists frequently experience NSI while performing FNA. Frequency of injury is also related to patient characteristics and work site factors. Education and motivation for adhering to standard precautions and post-exposure prophylaxis are often lacking.

  17. Real-time ultrasound elastography: an assessment of enlarged cervical lymph nodes.

    Science.gov (United States)

    Lo, Wu-Chia; Cheng, Po-Wen; Wang, Chi-Te; Liao, Li-Jen

    2013-09-01

    To determine the efficacy of real-time elastography (RTE), compared with our previously proposed prediction model, in the detection of malignancy in cervical lymph nodes (LNs). One hundred and thirty-one patients underwent ultrasound-guided fine needle aspiration biopsy (ultrasound FNAB) after ultrasound and RTE evaluation. The formula of the RTE scoring system was a four-point visual scale, based on a previously determined model. The formula of the prediction model was: [Formula: see text]. An extended model was constructed with four previous predictors and elasticity scores, using a logistic regression model. Final histology revealed 77 benign and 54 malignant LNs. In the elasticity score system, sensitivity was 66.7 %, specificity was 57.1 %, the positive predictive value (PPV) was 52.2 % and the negative predictive value (NPV) was 71.0 %. In the prediction model system, sensitivity was 79.6 %, specificity was 92.2 %, the PPV was 87.8 % and the NPV was 86.6 %. When the extended and the original model were compared, the areas under the receiver operating characteristic curve (c-statistic) was 0.94 and 0.95, respectively (P > 0.05). Qualitative RTE offers no additional value over conventional ultrasound in predicting malignancy in cervical LNs. • An ultrasound system can help in the assessment of cervical lymph nodes. • Grey-scale and power Doppler ultrasound remain fundamental for neck nodal evaluation. • Qualitative real-time elastography provided no additional value compared with current prediction models.

  18. CT-guided core biopsy of malignant lung lesions: how many needle passes are needed?

    International Nuclear Information System (INIS)

    Lim, Chaehun; Han, Dae Hee; Lee, Kyo Young; Kim, Young Kyoon; Ko, Jeong Min

    2013-01-01

    The study aims to determine the number of needle pass in the CT-guided core needle biopsy (CNB) in making a diagnosis of pulmonary malignancy. A total of 434 CNB records were retrospectively reviewed. The specimen obtained from each needle pass was put in a formalin container and then labelled for separate histopathological reporting. The patients were divided into five groups according to the total number of needle passes (n=1, n=2, n=3, n=4 and n≥5). In each of the groups 2–4, it was analysed how many needle passes are required before a plateau in diagnostic yield is achieved. CNB produced 283 true-positive and 23 false-negative diagnosis of malignancy. Cumulative sensitivity significantly (P<0.05) increased between the first and second as well as the second and the third (if done) needle passes, but not between the third and fourth ones. Three coaxial needle passes might be optimal in the diagnosis of lung malignancy.

  19. Ultrasonography-guided fine-needle aspiration biopsy for thyroid nodules: effective technique and a peculiar smear method

    International Nuclear Information System (INIS)

    Park, Kyeong Rok; Rho, Myung Ho; Kim, Dong Wook; Koo, Yong Woon; Lee, Kyeong Hee; Kang, Tae Woo

    2006-01-01

    We wanted to evaluate the effective methods that are appropriate for an endemic area of thyroid disease and to compare the differences of cytologic diagnostic rates with and without using a peculiar smear technique. We analyzed the incidence rate of insufficient results, complications and the total procedure times of 1,126 thyroid nodules in 776 patients who underwent US-FNAB (ultrasonography-guided fine-needle aspiration biopsy) from January to December 2005. We compared the diagnostic rate between the two groups; the groups' tests were performed with a peculiar smear technique (Group A, n 313) or with a ventional smear technique (Group B, n = 250). According to the size of the thyroid nodule, the incidence rate of an insufficient result on US-FNAB and the mean total procedure time for 1126 thyroid nodules in 776 patients were measured as 16.9% (52/308) and 208 seconds for nodules under 0.5 cm, 9.8% (30/306) and 160 seconds for nodules between 0.5 cm-10 cm, and 6.0% (30/504) and 134 seconds for nodules over 1.0 cm. These 776 patients showed no significant complication, except for mild pain. In Group A, the incidence rate of an insufficient result was calculated as 15.1% (14/93) for the group with nodules under 0.5 cm, 5.3% (5/95) for the group with nodules between 0.5 cm-1.0 cm, 4.8% (6/125) for the group with nodules over 1.0 cm, and 8.0% (25/313) for the total A Group. In Group B, the incidence rate of an insufficient result was measured as 33.3% (15/45) for the group with nodules under 0.5 cm, 28.1% (25/89) for the group with nodules between 0.5 cm-1.0 cm, 21.4% (24/112) for the group with nodules over 1.0 cm, and 25.7% (63/245) for the total B group. There was a statistically significant correlation between the rate of an insufficient result and the peculiar smear technique or the size of the thyroid nodule. We consider that US-FNAB is very simple, safe and accurate diagnostic method for thyroid nodules, and US-FNAB with a peculiar smear technique is able to

  20. Computed tomography-guided core-needle biopsy of lung lesions: an oncology center experience

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcos Duarte; Fonte, Alexandre Calabria da; Chojniak, Rubens, E-mail: marcosduarte@yahoo.com.b [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. of Radiology and Imaging Diagnosis; Andrade, Marcony Queiroz de [Hospital Alianca, Salvador, BA (Brazil); Gross, Jefferson Luiz [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. of Chest Surgery

    2011-03-15

    Objective: The present study is aimed at describing the experience of an oncology center with computed tomography guided core-needle biopsy of pulmonary lesions. Materials and Methods: Retrospective analysis of 97 computed tomography-guided core-needle biopsy of pulmonary lesions performed in the period between 1996 and 2004 in a Brazilian reference oncology center (Hospital do Cancer - A.C. Camargo). Information regarding material appropriateness and the specific diagnoses were collected and analyzed. Results: Among 97 lung biopsies, 94 (96.9%) supplied appropriate specimens for histological analyses, with 71 (73.2%) cases being diagnosed as malignant lesions and 23 (23.7%) diagnosed as benign lesions. Specimens were inappropriate for analysis in three cases. The frequency of specific diagnosis was 83 (85.6%) cases, with high rates for both malignant lesions with 63 (88.7%) cases and benign lesions with 20 (86.7%). As regards complications, a total of 12 cases were observed as follows: 7 (7.2%) cases of hematoma, 3 (3.1%) cases of pneumothorax and 2 (2.1%) cases of hemoptysis. Conclusion: Computed tomography-guided core needle biopsy of lung lesions demonstrated high rates of material appropriateness and diagnostic specificity, and low rates of complications in the present study. (author)

  1. Incisional endometriosis: diagnosed by fine needle aspiration cytology.

    Science.gov (United States)

    Veda, P; Srinivasaiah, M

    2010-07-01

    Incisional endometriosis (IE) is a rare entity reported in 0.03-1.08% of women following obstetric or gynecologic surgeries. Most cases reported in literature have appeared after cesarean sections and were often clinically mistaken for hernia, abscess, suture granuloma or lipoma. We hereby report a case of IE following a second trimester hysterotomy, which was diagnosed by fine needle aspiration cytology (FNAC). Our patient was 26 years old, presenting with a mass over anterior abdominal wall, associated with incapacitating pain during each menstrual cycle. FNAC showed epithelial cells, stromal cells and hemosiderin laden macrophages. Based on the typical history, clinical and cytological features, the diagnosis of IE was established. Wide surgical excision was done and the resulting rectus sheath defect was repaired. Patient was followed for 6 months during which time she was symptom free. This article also reviews the spectrum of cytological features and the rare possibility of malignant transformation that can occur in IE.

  2. Robot-assisted 3D-TRUS guided prostate brachytherapy: System integration and validation

    International Nuclear Information System (INIS)

    Wei Zhouping; Wan Gang; Gardi, Lori; Mills, Gregory; Downey, Donal; Fenster, Aaron

    2004-01-01

    Current transperineal prostate brachytherapy uses transrectal ultrasound (TRUS) guidance and a template at a fixed position to guide needles along parallel trajectories. However, pubic arch interference (PAI) with the implant path obstructs part of the prostate from being targeted by the brachytherapy needles along parallel trajectories. To solve the PAI problem, some investigators have explored other insertion trajectories than parallel, i.e., oblique. However, parallel trajectory constraints in current brachytherapy procedure do not allow oblique insertion. In this paper, we describe a robot-assisted, three-dimensional (3D) TRUS guided approach to solve this problem. Our prototype consists of a commercial robot, and a 3D TRUS imaging system including an ultrasound machine, image acquisition apparatus and 3D TRUS image reconstruction, and display software. In our approach, we use the robot as a movable needle guide, i.e., the robot positions the needle before insertion, but the physician inserts the needle into the patient's prostate. In a later phase of our work, we will include robot insertion. By unifying the robot, ultrasound transducer, and the 3D TRUS image coordinate systems, the position of the template hole can be accurately related to 3D TRUS image coordinate system, allowing accurate and consistent insertion of the needle via the template hole into the targeted position in the prostate. The unification of the various coordinate systems includes two steps, i.e., 3D image calibration and robot calibration. Our testing of the system showed that the needle placement accuracy of the robot system at the 'patient's' skin position was 0.15 mm±0.06 mm, and the mean needle angulation error was 0.07 deg. . The fiducial localization error (FLE) in localizing the intersections of the nylon strings for image calibration was 0.13 mm, and the FLE in localizing the divots for robot calibration was 0.37 mm. The fiducial registration error for image calibration was 0

  3. The effect of ultrasound-guided compression immediately after transrectal ultrasound-guided prostate biopsy on postbiopsy bleeding: a randomized controlled pilot study.

    Science.gov (United States)

    Park, Bong Hee; Kim, Jung Im; Bae, Sang Rak; Lee, Yong Seok; Kang, Sung Hak; Han, Chang Hee

    2017-08-01

    To evaluate whether ultrasound-guided compression performed immediately after transrectal ultrasound (TRUS)-guided prostate biopsy decreases bleeding complications. We prospectively evaluated a total of 148 consecutive patients who underwent TRUS-guided prostate biopsy between March 2015 and July 2016. Systematic 12-core prostate biopsy was performed in all patients. Of these, 100 patients were randomly assigned to one of two groups: the compression group (n = 50) underwent TRUS-guided compression on bleeding biopsy tracts immediately after prostate biopsy, while the non-compression group (n = 50) underwent TRUS-guided prostate biopsy alone. The incidence rate and duration of hematuria, hematospermia, and rectal bleeding were compared between the two groups. The incidence rates of hematuria and hematospermia were not significantly different between the two groups (60 vs. 64%, p = 0.68; 22 vs. 30%, p = 0.362, respectively, for compression vs. non-compression group). The rectal bleeding incidence was significantly lower in the compression group as compared to the non-compression group (20 vs. 44%, p = 0.01). However, there were no significant differences in the median duration of hematuria, hematospermia, or rectal bleeding between the two groups (2, 8, and 2 days vs. 2, 10, and 1 days, p > 0.05, respectively, for compression vs. non-compression group). TRUS-guided compression [p = 0.004, odds ratio (OR) 0.25] and patient age (p = 0.013, OR 0.93) were significantly protective against the occurrence of rectal bleeding after prostate biopsy in multivariable analysis. Although it has no impact on other complications, ultrasound-guided compression on bleeding biopsy tracts performed immediately after TRUS-guided prostate biopsy is an effective and practical method to treat or decrease rectal bleeding.

  4. A randomized comparison between neurostimulation and ultrasound-guided lateral femoral cutaneous nerve block.

    Science.gov (United States)

    Gupta, Gaurav; Radhakrishna, Mohan; Tamblyn, Isaac; Tran, D Q; Besemann, Markus; Thonnagith, Atikun; Elgueta, Maria Francisca; Robitaille, Marie Eve; Finlayson, Roderick J

    2017-01-01

    This prospective, randomized trial compared neurostimulation (NS) and ultrasound (US) guided lateral femoral cutaneous nerve (LFCN) block. We hypothesized that US would result in a shorter total anesthesia-related time (sum of performance and onset times). Twenty-one volunteers were enrolled. The right lower limb was randomized to an NS- or US-guided LFCN block. The alternate technique was employed for the left lower limb. With NS, paresthesias were sought in the lateral thigh at a stimulatory threshold of 0.6 mA (pulse width=0.3 ms; frequency=2 Hz) or lower. With US, local anesthetic was deposited under the inguinal ligament, ventral to the iliopsoas muscle. In both groups, 5 mL of lidocaine 2% were used to anesthetize the nerve. During the procedure of the block, the performance time and number of needle passes were recorded. Subsequently, a blinded observer assessed sensory block in the lateral thigh every minute until 20 minutes. Success was defined as loss of pinprick sensation at a point midway between the anterior superior iliac spine and the lateral knee line. The blinded observer also assessed the areas of sensory block in the anterior, medial, lateral, and posterior aspects of the thigh and mapped this distribution onto a corresponding grid. Both modalities provided comparable success rates (76.2%-95.2%), performance times (162.1 to 231.3 seconds), onset times (300.0 to 307.5 seconds) and total anesthesia related-times (480.1 to 554.0 seconds). However US required fewer needle passes (3.2±2.9 vs 9.5±12.2; P=.009). There were no intergroup differences in terms of the distribution of the anesthetized cutaneous areas. However considerable variability was encountered between individuals and between the 2 sides of a same subject. The most common areas of sensory loss included the central lateral two-eighths anteriorly and the central antero-inferior three-eighths laterally. Ultrasound guidance and NS provide similar success rates and total anesthesia

  5. Fine-needle aspiration cytology as a diagnostic modality for cysticercosis: A clinicocytological study of 137 cases

    Directory of Open Access Journals (Sweden)

    Pooja Kala

    2014-01-01

    Conclusion: Fine-needle aspiration cytology in cysticercosis is a low-cost outpatient procedure. The cytological diagnosis is quite straightforward in cases where the actual parasite structures are identified in the smears. In other cases, a cytological diagnosis of suspicious of cysticercosis can be given if the cytological findings suggest the same.

  6. Image-guided biopsy in patients with suspected ovarian carcinoma: a safe and effective technique?

    International Nuclear Information System (INIS)

    Griffin, Nyree; Grant, Lee A.; Freeman, Susan J.; Berman, Laurence H.; Sala, Evis; Jimenez-Linan, Mercedes; Earl, Helena; Ahmed, Ahmed Ashour; Crawford, Robin; Brenton, James

    2009-01-01

    In patients with suspected advanced ovarian carcinoma, a precise histological diagnosis is required before commencing neo-adjuvant chemotherapy. This study aims to determine the diagnostic accuracy and complication rate of percutaneous biopsies performed under ultrasound or computed tomography guidance. Between 2002 to 2007, 60 consecutive image-guided percutaneous biopsies were performed in patients with suspected ovarian cancer. The following variables were recorded: tissue biopsied, imaging technique, experience of operator, biopsy needle gauge, number of passes, complications, and final histology. Forty-seven patients had omental biopsies, 12 pelvic mass biopsies, and 1 para-aortic lymph node biopsy. Thirty-five biopsies were performed under ultrasound, 25 under computed tomography guidance. Biopsy needle gauges ranged from 14-20 swg with two to five passes for each patient. There were no complications. Histology was obtained in 52 (87%) patients. Percutaneous image-guided biopsy of peritoneal disease or pelvic mass is safe with high diagnostic accuracy. The large-gauge biopsy needle is as safe as the small gauge needle, but has the added value of obtaining tissue samples for immunohistochemistry and genomic studies. (orig.)

  7. Ultrasound- versus palpation-guided injection of corticosteroid for plantar fasciitis: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Zonghuan Li

    Full Text Available It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis.Databases (MEDLINE, Cochrane library and EMBASE and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS, tenderness threshold (TT, heel tenderness index (HTI, response rate, plantar fascia thickness (PFT, hypoechogenicity and heel pad thickness (HPT. The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE system was used to assess the quality of evidence.Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI.Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research.

  8. Ultrasound- versus Palpation-Guided Injection of Corticosteroid for Plantar Fasciitis: A Meta-Analysis

    Science.gov (United States)

    Yu, Aixi; Qi, Baiwen

    2014-01-01

    Background It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis. Methods Databases (MEDLINE, Cochrane library and EMBASE) and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs) comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB) tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS), tenderness threshold (TT), heel tenderness index (HTI), response rate, plantar fascia thickness (PFT), hypoechogenicity and heel pad thickness (HPT). The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was used to assess the quality of evidence. Results Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI. Conclusion Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research. PMID:24658102

  9. Application of a topical vapocoolant spray decreases pain at the site of initial intradermal anaesthetic injection during ultrasound-guided breast needle biopsy

    International Nuclear Information System (INIS)

    Collado-Mesa, F.; Net, J.M.; Arheart, K.; Klevos, G.A.; Yepes, M.M.

    2015-01-01

    Aim: To assess whether the application of a topical vapocoolant spray immediately prior to initial intradermal anaesthetic injection during ultrasound-guided breast biopsy decreases pain at the site of the initial injection. Materials and methods: In this institutional review board-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant study, 50 women aged 49.1 ± 1.6 years (mean ± standard error) were recruited and provided written informed consent. Participants served as their own controls and were blinded as to whether a topical vapocoolant spray or a placebo was used immediately prior to the initial local anaesthetic injection at two separate biopsy sites. With the exception of the application of vapocoolant or placebo, the entire ultrasound-guided procedure was performed according to a routine protocol. Participants recorded pain at initial injection site on a visual analogue scale. General linear mixed models for repeated measures analysis of variance and a 0.05 significance level were used. Results: Application of topical vapocoolant spray was shown to significantly decrease pain at the site of initial intradermal anaesthetic injection as compared to placebo (p<0.001). Treatment effect was independent of age of the subject, race/ethnicity, operator, type of biopsy device, and histopathology result. No complications from vapocoolant spray use were reported. Conclusion: Application of a topical vapocoolant spray immediately prior to initial intradermal anaesthetic injection during ultrasound-guided breast biopsy significantly decreases pain at the site of the initial injection and could contribute to improve the patient's overall procedural experience. -- Highlights: •Topical vapocoolant spray decreased pain at site of initial anesthetic injection (

  10. The diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Hui; Zhang Fuchen; Ji Hongjian; Chen Liping

    2009-01-01

    Objective: To evaluate the diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions. Methods: The clinical data of CT-guided transthoracic cutting needle biopsy in 436 patients performed in past 10 years were retrospectively analyzed. Of 436 cases with pulmonary lesions, primary lung cancer was confirmed in 341, pulmonary metastasis in 62, non-malignant lesions in 33. The diagnostic accuracy and sensitivity were statistically analyzed. The occurrence of complications was discussed. Results: The diagnostic accuracy rate and sensitivity rate in primary lung cancer group were 94.7% and 94.1% respectively, in pulmonary metastasis group were 58.2% and 51.6% respectively and in non-malignant lesions group were 57.6% and 57.6% respectively. The successful rate of biopsy was 97.9%. The occurrence of complications was 15.6%. Conclusion: CT-guided percutaneous transthoracic cutting needle biopsy is a safe and valuable diagnostic technique with high diagnostic accuracy and less complications. It is very helpful in confirming the diagnosis in the patients with suspected primary pulmonary cancer, although the technical procedures need to be further improved for metastatic and non-malignant lung lesions. (authors)

  11. CT-guided biopsy with cutting-edge needle for the diagnosis of malignant lymphoma: Experience of 267 biopsies

    International Nuclear Information System (INIS)

    Agid, R.; Sklair-Levy, M.; Bloom, A.I.; Lieberman, S.; Polliack, A.; Ben-Yehuda, D.; Sherman, Y.; Libson, E.

    2003-01-01

    AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18 G or 20 G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma Agid,R. et al. (2003). Clinical Radiology58, 143-147

  12. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... assistance of a nurse and an MR imaging technologist. As with the ultrasound procedure, you may receive antibiotics, sedatives and pain medication before the biopsy. The MRI-guided procedure may use contrast ... A nurse or technologist will insert an intravenous (IV) catheter into a ...

  13. Bedside Ultrasound for the Diagnosis of Peritonsillar Abscess

    Directory of Open Access Journals (Sweden)

    Harshal Bhakta

    2017-09-01

    Full Text Available History of present illness: A 34-year-old male presented to the Emergency Department with fever, sore throat, and difficulty swallowing. On exam, the patient had trismus, a deviated uvula, and swelling of his left peritonsillar space. An intraoral point of care ultrasound (POCUS was performed, which revealed a fluid collection in the patient’s left peritonsillar space. The patient was diagnosed with a peritonsillar abscess (PTA and needle aspiration was performed under direct ultrasound guidance. The patient tolerated the procedure well and was sent home with a course of antibiotics. Significant findings: The first video is an intraoral ultrasound using the high frequency endocavitary probe demonstrating an anechoic fluid collection adjacent to the patient’s enlarged left tonsil. The second video shows real-time ultrasound-guided successful drainage of the PTA. Discussion: Peritonsillar abscesses are the most common deep space infection of the head and neck1, most commonly affecting children and young adults.2 The ability of physicians to accurately differentiate PTA from peritonsillar cellulitis (PTC by physical exam alone is limited. Traditionally, PTA has been treated using landmark-based needle aspiration.3 If unsuccessful, computed tomography (CT imaging and otolaryngology (ENT consultation is usually required.3 Although diagnosis of PTA using intraoral ultrasound has a sensitivity and specificity of between 89%-95% and 79%-100% respectively, it is still underutilized in comparison to these traditional methods.4 Studies have shown the use of ultrasound for diagnosis and treatment of PTA leads to significantly better outcomes and higher success rates of drainage (when compared to landmark-based needle aspiration, less need for CT imaging, and less need for ENT consultation.3 Utilizing intraoral point-of-care ultrasound is an efficient, safe, and cost-effective way of diagnosing and treating PTA.

  14. Intraoperative translabial ultrasound for urethral diverticula: A road map for surgeons

    International Nuclear Information System (INIS)

    El-Zein, C.; Khoury, N.; El-Zein, Y.; Bulbul, M.; Birjawi, G.

    2009-01-01

    Purpose: To highlight the importance of intraoperative translabial ultrasound, for identification of diverticular neck allowing complete resection of periurethral diverticula and decrease in the recurrence rate. Material and methods: This study included 4 women of age range between 38 and 68 years presenting for recurrent urinary tract infections and urethral pain. All had translabial urethral ultrasound and cystoscopy with and without U/C guidance. Results: Prior cystoscopy in all these patients failed to demonstrate the diverticulum. Translabial ultrasound showed the diverticula some of which were infected. Ultrasound was used intraoperatively to guide the surgeon. With this approach the abnormality was confirmed and the neck of the diverticulum was identified through percutaneous needle insertion. This allowed complete resection of the diverticula. Conclusion: Translabial ultrasound is a non-invasive technique that plays a major role in examining the urethra and identifying the periuthral diverticula. In our experience, it was very useful as an adjunct to guide the surgeon intraoperatively allowing complete excision of the diverticulum.

  15. Intraoperative translabial ultrasound for urethral diverticula: A road map for surgeons

    Energy Technology Data Exchange (ETDEWEB)

    El-Zein, C.; Khoury, N.; El-Zein, Y. [Department of Diagnostic Radiology, American University of Beirut Medical Center, Bliss Street, P.O. Box 11-0236, Riad El Solh 1107 2020, Beirut (Lebanon); Bulbul, M. [Department of Urology, American University of Beirut Medical Center, Bliss Street, P.O. Box 11-0236, Riad El Solh 1107 2020, Beirut (Lebanon); Birjawi, G. [Department of Diagnostic Radiology, American University of Beirut Medical Center, Bliss Street, P.O. Box 11-0236, Riad El Solh 1107 2020, Beirut (Lebanon)], E-mail: gb02@aub.edu.lb

    2009-04-15

    Purpose: To highlight the importance of intraoperative translabial ultrasound, for identification of diverticular neck allowing complete resection of periurethral diverticula and decrease in the recurrence rate. Material and methods: This study included 4 women of age range between 38 and 68 years presenting for recurrent urinary tract infections and urethral pain. All had translabial urethral ultrasound and cystoscopy with and without U/C guidance. Results: Prior cystoscopy in all these patients failed to demonstrate the diverticulum. Translabial ultrasound showed the diverticula some of which were infected. Ultrasound was used intraoperatively to guide the surgeon. With this approach the abnormality was confirmed and the neck of the diverticulum was identified through percutaneous needle insertion. This allowed complete resection of the diverticula. Conclusion: Translabial ultrasound is a non-invasive technique that plays a major role in examining the urethra and identifying the periuthral diverticula. In our experience, it was very useful as an adjunct to guide the surgeon intraoperatively allowing complete excision of the diverticulum.

  16. Usefulness of screening ultrasound for thyroid gland

    International Nuclear Information System (INIS)

    Park, Soo Youn; Han, Heon; Park, Man Soo

    2006-01-01

    The purpose of this study was to investigate the usefulness of the ultrasonography as a screening test for thyroid diseases. For 7 months, thyroid ultrasonography (7.5 MHz linear array) was performed prospectively by radiologists on 1,316 subjects who do not have a history of the thyroid disease. We analyzed the morphological abnormalities of thyroid gland and these were classified as the nodulal, cystic and diffuse types in accordance with the gender and ages of the patients. We performed ultrasound-guided fine needle aspiration in 21 patients who had sonographic features that were suggestive of malignant thyroid nodules. Physical examination was performed for all subjects by clinicians before the thyroid ultrasonography, and we compared the detectability of thyroid lesions between ultrasonography and physical examination. Thyroidal abnormalities were detected in 94 (7.1%) of 1,316 subjects. Among the 94 patients, 72(5.5%) showed as nodules, 18 (1.4%) showed as cysts and 4 (0.3%) showed as diffuse abnormalities. The result of the ultrasound-guided aspiration on 21 patients showed 4 malignant nodules, 16 benign nodules and 1 undetermined nodule. Physical examination detected abnormalities in only 12 patients (12.8%) of the 94 patients, which were showed as nodules, cysts and the diffuse type by ultrasonography. Thyroid disease of the general population was relatively common and the detection rate with performing physical examination for the thyroid nodule, cyst and the diffuse type was lower than that for ultrasonography. Thyroid ultrasonography is a useful screening modality for detecting thyroid diseases

  17. Fine needle biopsy of thyroid nodules: correlations between cytology and gistology, technical aspects

    Directory of Open Access Journals (Sweden)

    Yu Fedotov

    2009-12-01

    Full Text Available The results of comparative preoperative cytological and postoperative histological investigation of 3714 patients with thyroid nodules are presented. The causes of discrepancies are discussed and measures of their diminution are proposed. Great value of fine needle biopsy to differ thyroid nodules but follicular neoplasia into benign and malignant are determined. Its sensitivity in our clinics is 98.7% and specificity – 100%. Necessity of the of the second FNA if the first one is non informative is established.

  18. Strain elastography of abnormal axillary nodes in breast cancer patients does not improve diagnostic accuracy compared with conventional ultrasound alone.

    Science.gov (United States)

    Park, Young Mi; Fornage, Bruno D; Benveniste, Ana Paula; Fox, Patricia S; Bassett, Roland L; Yang, Wei Tse

    2014-12-01

    The purpose of this study was to determine the diagnostic value of strain elastography (SE) alone and in combination with gray-scale ultrasound in the diagnosis of benign versus metastatic disease for abnormal axillary lymph nodes in breast cancer patients. Patients with breast cancer and axillary lymph nodes suspicious for metastatic disease on conventional ultrasound who underwent SE of the suspicious node before ultrasound-guided fine-needle aspiration biopsy (FNAB) were included in this study. On conventional ultrasound, the long- and short-axis diameters, long-axis-to-short-axis ratio, cortical echogenicity, thickness, and evenness were documented. The nodal vascularity was assessed on power Doppler imaging. Elastograms were evaluated for the percentage of black (hard) areas in the lymph node, and the SE-ultrasound size ratio was calculated. Two readers assessed the images independently and then in consensus in cases of disagreement. ROC AUCs were calculated for conventional ultrasound, SE, and both methods combined. Interreader reliability was assessed using kappa statistics. A total of 101 patients with 104 nodes were examined; 35 nodes were benign, and 69 had metastases. SE alone showed a significantly lower AUC (62%) than did conventional ultrasound (92%) (pultrasound and the AUC of the combination of conventional ultrasound and SE (93%) (p=0.16). Interreader reliability was moderate for all variables (κ≥0.60) except the SE-ultrasound size ratio (κ=0.35). Added SE does not improve the diagnostic ability of conventional ultrasound when evaluating abnormal axillary lymph nodes.

  19. SU-D-210-07: The Dependence On Acoustic Velocity of Medium On the Needle Template and Electronic Grid Alignment in Ultrasound QA for Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kapoor, P; Kapoor, R; Curran, B [Virginia Commonwealth University, Richmond, VA (United States); HH McGuire VA Hospital, Richmond, VA (United States)

    2015-06-15

    Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work, two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.

  20. The factor analysis of the incidence of pneumothorax after CT-guided transthoracic needle aspiration biopsy

    International Nuclear Information System (INIS)

    Zhong Tao; Yu Hongguang; Wang Yong; Yang Sifu; Wang Xiaoxuan

    2007-01-01

    Objective: To analyze the impact of multiple factors on the incidence of pneumothorax associated with CT-guided transthoracic needle aspiration biopsy. Methods: The sign of pneumothorax after 162 cases (lesion diameter from 1 cm to 6 cm) CT-guided transthoracic needle aspiration biopsy was observed and its relationship with multivariate factors were analyzed by multivariate logistic regression model. Results: Thirty-two cases presented pneumothorax accounting for 19. 8%. Single variate analysis showed that the sign of pneumothorax related to intercurrent COPD, distance from lesion and chest wall, needle dwelling time and lesion diameter. 67 patients of intercurrent COPD with postoperative pneumothorax occurred in 22 cases (32.8%); With respect to those having lesions close to the chest wall (48 cases), and the cases with the distance between the chest wall and lesions less than 2 cm (55 cases) and greater than 2 cm (59 cases), the postoperative pneumothorax occurred in 0, 14 (25.5%), 18 (30.5%) cases respectively; For those patients with needle in the chest residence time of less than 10 minutes (82 cases), 10-20 minutes (51 cases), more than 20 minutes (28 cases) after the occurrence of pneumothorax were 8 (9.6%), 10(19.6%), 14 (50%) cases respectively; In contrast, those with lesion diameter less than 2 cm (65 cases), 2-4 cm(52 cases), more than 4cm(45 cases) were 19 (29.2%), 8 (15.4%) and 5 (11.1% ) respectively. The multivariate logistic regression analysis showed that the prior three factor's were risk factors of pneumothorax (OR=4.652, 4.030, 2.855 respectively). Conclusions: To avoid the pneumothorax, caution must be taken with respect to CT-guided transthoracic needle aspiration biopsy, patients with intercurrent COPD, long distance between lesion and chest wall, and smaller lesion diameter. For operation the needle dwell time within thorax should be minimized. (authors)