  1. Double Purse-String Telescoped Pancreaticogastro stomy using an Atraumatic Self-retaining Ring Retractor in a Subtotal Stomach-Preserving Pancreaticoduodenectomy.

    Science.gov (United States)

    Narita, Masato; Matsusue, Ryo; Hata, Hiroaki; Yamaguchi, Takashi; Otani, Tetsushi; Ikai, Iwao

    2016-03-01

    Pancreatoenteric anastomotic failure is the main cause of pancreatic fistula after pancreaticoduodenectomy (PD). Double purse-string telescoped pancreaticogastrostomy, reported by Addeo et al., is an easy and safe procedure.1 The aim of this article was to introduce our technique of pancreaticogastrostomy using an atraumatic self-retaining ring retractor (Alexis Wound Retractor) in a patient undergoing subtotal stomach-preserving PD (SSPPD). An 82-year-old woman presented with pancreatic cancer located in the uncinate process of pancreas. She underwent SSPPD with resection of the superior mesenteric vein (SMV) and double purse-string telescoped pancreaticogastrostomy using an Alexis wound retractor. The pancreas was transected on the portal vein and the remnant pancreas was separated from the splenic vein and artery. After extirpation of specimens and reconstruction of the SMV, two seromuscular purse-string sutures were placed on the posterior wall of the upper stomach. The anterior wall of the upper stomach was incised and opened using an Alexis wound retractor. The remnant pancreas was inserted into the gastric cavity through the posterior wall of the stomach and sutured circumferentially with running stitches to fix on the gastric muco-muscular layer. After closure of the anterior wall of the stomach, purse-string sutures were tightened and pancreaticogastrostomy was completed. The patient's postoperative course was uneventful and a computed tomography imaging study revealed no fluid collection around the pancreaticogastrostomy. This patient was discharged on the 14th postoperative day. Use of an Alexis wound retractor makes it easier to perform a double purse-string telescoped pancreaticogastrostomy by a self-expanding property to allow a wide operative view.

  2. Total versus subtotal hysterectomy

    DEFF Research Database (Denmark)

    Gimbel, Helga; Zobbe, Vibeke; Andersen, Anna Birthe

    2005-01-01

    The aim of this study was to compare total and subtotal abdominal hysterectomy for benign indications, with regard to urinary incontinence, postoperative complications, quality of life (SF-36), constipation, prolapse, satisfaction with sexual life, and pelvic pain at 1-year postoperative. Eighty...... women chose total and 105 women chose subtotal abdominal hysterectomy. No significant differences were found between the 2 operation methods in any of the outcome measures at 12 months. Fourteen women (15%) from the subtotal abdominal hysterectomy group experienced vaginal bleeding and three women had...

  3. Subtotal versus total abdominal hysterectomy

    DEFF Research Database (Denmark)

    Andersen, Lea Laird; Ottesen, Bent; Alling Møller, Lars Mikael

    2015-01-01

    OBJECTIVE: The objective of the study was to compare long-term results of subtotal vs total abdominal hysterectomy for benign uterine diseases 14 years after hysterectomy, with urinary incontinence as the primary outcome measure. STUDY DESIGN: This was a long-term follow-up of a multicenter......, randomized clinical trial without blinding. Eleven gynecological departments in Denmark contributed participants to the trial. Women referred for benign uterine diseases who did not have contraindications to subtotal abdominal hysterectomy were randomized to subtotal (n = 161) vs total (n = 158) abdominal...... from discharge summaries from all public hospitals in Denmark. The results were analyzed as intention to treat and per protocol. Possible bias caused by missing data was handled by multiple imputation. The primary outcome was urinary incontinence; the secondary outcomes were pelvic organ prolapse...

  4. Sexuality after total vs. subtotal hysterectomy

    DEFF Research Database (Denmark)

    Zobbe, Vibeke Bahn; Gimbel, Helga Margrethe Elisabeth; Andersen, Birthe Margrethe

    2004-01-01

    The effect of hysterectomy on sexuality is not fully elucidated and until recently total and subtotal hysterectomies have only been compared in observational studies.......The effect of hysterectomy on sexuality is not fully elucidated and until recently total and subtotal hysterectomies have only been compared in observational studies....

  5. Acquired omental cystic lymphangioma after subtotal gastrectomy: a case report.

    Science.gov (United States)

    Kim, Jong Han; Ryu, Woo Sang; Min, Byung Wook; Song, Tae Jin; Son, Gil Soo; Kim, Seung Joo; Kim, Young Sik; Um, Jun Won

    2009-12-01

    We herein describe a case of cystic lymphangioma in the greater omentum of the remnant stomach, which is thought it to be related with subtotal gastrectomy 10 yr ago for early gastric cancer. A 76-yr-old man was admitted to our department with postprandial abdominal discomfort and bowel habit change. Intraabdominal multilocular cystic mass was detected by ultrasonography and computed tomography. We performed a complete En-bloc tumor resection including spleen and distal pancreas, and histological examination confirmed cystic lymphangioma originated from the greater omentum of the remnant stomach. Although the etiology of omental lymphangioma remains largely unclear, these findings suggested strongly that obstruction of the lymphatic vessels after gastric resection for gastric carcinoma might be the most plausible cause. The surgical extirpation with resection of organs involved appears to be a treatment of choice for such unusual case.

  6. Subtotal obstruction of the male reproductive tract

    NARCIS (Netherlands)

    Pierik, F.H.; Dohle, G.R.; Roijen, J.H. van; Vreeburg, J.T.M.; Weber, R.F.A.

    2003-01-01

    Bilateral obstruction of the male reproductive tract is suspected in men with azoospermia, normal testicular volume and normal FSH. A testicular biopsy is required to differentiate between an obstruction and a testicular insufficiency. Unilateral or subtotal bilateral obstructions and epididymal

  7. Thyroid Function after Subtotal Thyroidectomy in Patients with Graves' Hyperthyroidism

    NARCIS (Netherlands)

    Limonard, E. J.; Bisschop, P. H.; Fliers, E.; Nieveen van Dijkum, E. J.

    2012-01-01

    Background. Subtotal thyroidectomy is a surgical procedure, in which the surgeon leaves a small thyroid remnant in situ to preserve thyroid function, thereby preventing lifelong thyroid hormone supplementation therapy. Aim. To evaluate thyroid function after subtotal thyroidectomy for Graves'

  8. Subtotal Hemispherectomy, Report of Ten Cases

    Directory of Open Access Journals (Sweden)

    N. O. Ameli

    1960-01-01

    Full Text Available 10 cases submitted to subtotal hemispheretomy are discussed. In selected group of infantile hemiplegia where epilepsy and behaviour disturbances are pr~sent, and investigations prove that the other hemisphere is farly normal, thts operation is of greatt benefit. Ne,vertheless long follow-up of these cases IS necessary before a final judgement can be passed. Age should.be no barrier to selection, as those of 18 - 25 have benefited as much as young children

  9. CT of liver steatosis after subtotal pancreatectomy

    Energy Technology Data Exchange (ETDEWEB)

    Lundstedt, C; Andren-Sandberg, A [Lund Univ. (Sweden). Dept. of Diagnostic Radiology Lund Univ. (Sweden). Dept. of Surgery

    1991-01-01

    The liver attenuation of 50 patients operated with a subtotal pancreatectomy for pancreatic and duodenal tumors was evaluated with CT. Of 18 patients surviving more than 18 months after surgery, 7 developed a markedly reduced liver attenuation indicating liver steatosis. No patient became diabetic or showed evidence of malnutrition after surgery. No correlation between the liver attenuation values and the patients' liver function test was noted. The steatosis was reversible in 4 of the 7 patients. The pathophysiological cause of the steatosis remains unknown. Partial pancreatectomy should be included among the reasons listed for liver steatosis. (orig.).

  10. CT of liver steatosis after subtotal pancreatectomy

    Energy Technology Data Exchange (ETDEWEB)

    Lundstedt, C.; Andren-Sandberg, A. (Lund Univ. (Sweden). Dept. of Diagnostic Radiology Lund Univ. (Sweden). Dept. of Surgery)

    1991-01-01

    The liver attenuation of 50 patients operated with a subtotal pancreatectomy for pancreatic and duodenal tumors was evaluated with CT. Of 18 patients surviving more than 18 months after surgery, 7 developed a markedly reduced liver attenuation indicating liver steatosis. No patient became diabetic or showed evidence of malnutrition after surgery. No correlation between the liver attenuation values and the patients' liver function test was noted. The steatosis was reversible in 4 of the 7 patients. The pathophysiological cause of the steatosis remains unknown. Partial pancreatectomy should be included among the reasons listed for liver steatosis. (orig.).

  11. CT of liver steatosis after subtotal pancreatectomy

    International Nuclear Information System (INIS)

    Lundstedt, C.; Andren-Sandberg, A.; Lund Univ.

    1991-01-01

    The liver attenuation of 50 patients operated with a subtotal pancreatectomy for pancreatic and duodenal tumors was evaluated with CT. Of 18 patients surviving more than 18 months after surgery, 7 developed a markedly reduced liver attenuation indicating liver steatosis. No patient became diabetic or showed evidence of malnutrition after surgery. No correlation between the liver attenuation values and the patients' liver function test was noted. The steatosis was reversible in 4 of the 7 patients. The pathophysiological cause of the steatosis remains unknown. Partial pancreatectomy should be included among the reasons listed for liver steatosis. (orig.)

  12. [Pancreatic ultrasonography].

    Science.gov (United States)

    Fernández-Rodríguez, T; Segura-Grau, A; Rodríguez-Lorenzo, A; Segura-Cabral, J M

    2015-04-01

    Despite the recent technological advances in imaging, abdominal ultrasonography continues to be the first diagnostic test indicated in patients with a suspicion of pancreatic disease, due to its safety, accessibility and low cost. It is an essential technique in the study of inflammatory processes, since it not only assesses changes in pancreatic parenchyma, but also gives an indication of the origin (bile or alcoholic). It is also essential in the detection and tracing of possible complications as well as being used as a guide in diagnostic and therapeutic punctures. It is also the first technique used in the study of pancreatic tumors, detecting them with a sensitivity of around 70% and a specificity of 90%. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  13. Low adherence to cervical cancer screening after subtotal hysterectomy

    DEFF Research Database (Denmark)

    Andersen, Lea Laird; Møller, Lars Mikael Alling; Gimbel, Helga Margrethe

    2015-01-01

    INTRODUCTION: A reason for not recommending subtotal hysterectomy is the risk of cervical pathology. We aimed to evaluate cervical cancer screening and to describe cervical pathology after subtotal and total hysterectomy for benign indications. METHODS: Data regarding adherence to screening...... Hospital, Rigs-hospitalet and Roskilde Hospital, Denmark. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01880710....

  14. Palpation thyroiditis following subtotal parathyroidectomy for hyperparathyroidism

    Directory of Open Access Journals (Sweden)

    Elizabeth M Madill

    2016-07-01

    Full Text Available Thyrotoxicosis is an under-recognised but clinically important complication of parathyroidectomy. We report a case of a 37-year-old man with tertiary hyperparathyroidism who initially developed unexplained anxiety, diaphoresis, tachycardia, tremor and hyperreflexia one day after subtotal parathyroidectomy. Thyroid biochemistry revealed suppressed thyroid stimulating hormone and elevated serum free T4 and free T3 levels. Technetium-99m scintigraphy scan confirmed diffusely decreased radiotracer uptake consistent with thyroiditis. The patient was diagnosed with thyrotoxicosis resulting from palpation thyroiditis. Administration of oral beta-adrenergic antagonists alleviated his symptoms and there was biochemical evidence of resolution fourteen days later. This case illustrates the need to counsel patients about thyroiditis as one of the potential risks of parathyroid surgery. It also emphasises the need for biochemical surveillance in patients with unexplained symptoms in the post-operative period and may help to minimise further invasive investigations for diagnostic clarification.

  15. Radiotherapy after subtotally resected or recurrent ganglioglioma

    International Nuclear Information System (INIS)

    Liauw, Stanley L.; Byer, Jennifer E.; Yachnis, Anthony T.; Amdur, Robert J.; Mendenhall, William M.

    2007-01-01

    Purpose: Gangliogliomas can recur after subtotal resection (STR). The role of postoperative radiation therapy (RT) is undefined. Methods and Materials: Eight consecutive patients with low-grade gangliogliomas (n = 7) or anaplastic gangliogliomas (n = 1) were treated with RT between 1987 and 2004. Median age was 17 years. Five patients received adjuvant RT after STR at a median time of 6 weeks after surgery. Three patients received salvage RT at a median time of 17 months after surgery. The median dose of RT was 54 Gy. Control was defined as no progressive disease on serial imaging. Median follow-up was 8.8 years. Results: Of the 7 patients with low-grade gangliogliomas, 3 were controlled after RT and 4 recurred locally. Recurrences were controlled with further surgery (n = 2), chemotherapy (n 1), or re-irradiation (n = 1) (median follow-up, 9 years after salvage therapy). Patients who received adjuvant RT after STR of their low-grade gangliogliomas had an overall local control rate of 75%. All 3 patients who were treated with salvage RT had recurrences in the treated area alone (n 2) or in the treated area with leptomeningeal spread (n = 1). The patient with an anaplastic ganglioglioma was treated with adjuvant RT, and had recurrence in Radiation field after 4 months, then died 1 month later. Conclusions: Adjuvant RT may be indicated to treat select patients with subtotally resected gangliogliomas. Salvage RT for recurrence is probably less effective for long-term control; however, patients who recur may still be candidates for effective salvage therapies in the absence of malignant transformation

  16. Lower urinary tract symptoms after subtotal versus total abdominal hysterectomy

    DEFF Research Database (Denmark)

    Andersen, Lea Laird; Møller, Lars Mikael Alling; Gimbel, Helga

    2015-01-01

    INTRODUCTION AND HYPOTHESIS: Lower urinary tract symptoms (LUTS) are common after hysterectomy and increase after menopause. We aimed to compare subtotal with total abdominal hysterectomy regarding LUTS, including urinary incontinence (UI) subtypes, 14 years after hysterectomy. Main results from...

  17. Subtotal obstruction of the male reproductive tract.

    Science.gov (United States)

    Dohle, G R; van Roijen, J H; Pierik, F H; Vreeburg, J T M; Weber, R F A

    2003-03-01

    Bilateral obstruction of the male reproductive tract is suspected in men with azoospermia, normal testicular volume and normal FSH. A testicular biopsy is required to differentiate between an obstruction and a testicular insufficiency. Unilateral or subtotal bilateral obstructions and epididymal dysfunction may cause severe oligozoospermia in men with a normal spermatogenesis. However, information on spermatogenesis in oligozoospermic men is lacking, since testicular biopsy is not routinely performed. Men with a sperm concentration of scoring method. A testicular biopsy was performed in 78 men with severe oligozoospermia. The medical history showed male accessory gland infection in 12.8%, previous hernia repair in 14.1% and a history of cryptorchidism in 12.8%. A normal or slightly disturbed spermatogenesis (Johnsen score >8) was present in 39/78 (50%) of the men. Hernia repair occurred more often in men with normal spermatogenesis. A varicocele was predominantly seen in men with a disturbed spermatogenesis. FSH was significantly lower ( Preproductive tract is a frequent cause of severe oligozoospermia in men with a normal testicular volume and a normal FSH. In other cases, an epididymal dysfunction might explain the oligozoospermia in men with a normal testicular biopsy score.

  18. Late postoperative follow-up of patients undergoing subtotal splenectomy Acompanhamento pós-operatório tardio de pacientes submetidos a esplenectomia subtotal

    Directory of Open Access Journals (Sweden)

    Andy Petroianu

    2005-12-01

    Full Text Available PURPOSE: Over the past 21 years, we have performed more than 200 subtotal splenectomies, in which the upper splenic pole vascularized only by the gastrosplenic pole vascularized only by the gastrosplenic vessels is preserved, to treat different pathologic conditions. A meticulous follow-up of the postoperative results of this procedure is of fundamental importance. METHODS: All patients undergoing subtotal splenectomy were invited to be reviewed. A total of 86 patients who had undergone surgery 1 to 20 years ago were gathered; the surgical procedure was performed for one of the following conditions: portal hypertension due to schistosomiasis (n = 43, trauma (n = 31, Gaucher's disease (n = 4, myeloid hepatosplenomegaly due to myelofibrosis (n = 3, splenomegalic retarded growth and sexual development (n = 2, severe pain due to splenic ischemia (n = 2 and pancreatic cystadenoma (n = 1. Patients underwent a hematologic exam, an immunologic assessment, abdominal ultrasonography, computed tomography, scintigraphy and endoscopy. RESULTS: Increased white blood cell count and platelets were the only hematological abnormalities. No immunologic deficit was found. Esophageal varices were still present in patients who underwent surgery because of portal hyperension although without rebleeding. The ultrasound, tomography and scintigraphy exams confirmed the presence of functional splenic remnants without significant size alteration. CONCLUSIONS: Subtotal splenectomy seems to be a safe procedure that can be useful in treating conditions involving the spleen. The functions of the splenic remnants are preserved during long periods of time.OBJETIVO: Durante 21 anos, realizamos mais de 200 esplenectomias subtotais para tratar diferentes condições patológicas. É fundamental conhecer os resultados pós-operatórios desse procedimento. MÉTODO: Todos os pacientes submetidos a esplenectomia subtotal foram convidados para serem submetidos a revisão. Pudemos reunir

  19. Therapeutic use of fractionated total body and subtotal body irradiation

    International Nuclear Information System (INIS)

    Loeffler, R.K.

    1981-01-01

    Ninety-one patients were treated using fractionated subtotal body (STBI) or total body irradiation (TBI). These patients had generalized lymphomas, Hodgkin's disease, leukemias, myelomas, seminomas, or oat-cell carcinomas. Subtotal body irradiation is delivered to the entire body, except for the skull and extremities. It was expected that a significantly higher radiation dose could be administered with STBI than with TBI. A five- to ten-fold increase in tolerance for STBI was demonstrated. Many of these patients have had long-term emissions. There is little or no treatment-induced symptomatology, and no sanctuary sites

  20. Ultrasonography versus intravenous urography

    International Nuclear Information System (INIS)

    Aslaksen, A.

    1991-01-01

    The present study was performed to compare the clinical value of urography and ultrasonography in a non-selected group of patients referred for urography to a university hospital. The conslusions and clinical implications of the study are as follows: Intravenous urography remains the cornerstone imaging examination in the evaluation of ureteral calculi. Ultrasonography is a valuable adjunct in cases of non- visualization of the kidneys, in distal obstruction and known contrast media allergy. When women with recurrent urinary tract infection are referred for imaging of the urinary tract, ultrasonography should be used. Ultrasonography should replace urography for screening of non-acute hydronephrosis like in female genital cancer and benign prostate hyperplasia. There is good correlation between urography and ultrasonography in assessing the degree of hydronephrosis. However, more researh on the relationship between hydronephrosis and obstruction is necessary. Ultrasonography should be used as the only imaging method of the upper urinary tract in patients with microscopic hematuria. In patients less than 50 years with macroscopic hematuria, ultrasonography should be used as the only imaging of the upper urinary tract, and an examination of the urinary bladder should be included. In patients over 50 years, urography supplied with ultrasonography should be used, but more research is necessary on the subject of imaging method and age. 158 refs

  1. Subtotal ablation of parietal epithelial cells induces crescent formation.

    NARCIS (Netherlands)

    Sicking, E.M.; Fuss, A.; Uhlig, S.; Jirak, P.; Dijkman, H.; Wetzels, J.; Engel, D.R.; Urzynicok, T.; Heidenreich, S.; Kriz, W.; Kurts, C.; Ostendorf, T.; Floege, J.; Smeets, B.; Moeller, M.J.

    2012-01-01

    Parietal epithelial cells (PECs) of the renal glomerulus contribute to the formation of both cellular crescents in rapidly progressive GN and sclerotic lesions in FSGS. Subtotal transgenic ablation of podocytes induces FSGS but the effect of specific ablation of PECs is unknown. Here, we established

  2. Subtotal amelia in a child with autosomal recessive hypohidrotic ...

    African Journals Online (AJOL)

    We report an inbred Tunisian family, in which the proband manifested signs of hypohidrotic ectodermal dysplasia, subtotal amelia, scoliosis and left renal agenesis. Two other family members had the full clinical criteria of hypohidrotic ectodermal dysplasia, characterized by deficient sweat glands, hypodontia, hypoplasia of ...

  3. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  4. Objective comparison of subtotal vs. total abdominal hysterectomy regarding pelvic organ prolapse and urinary incontinence

    DEFF Research Database (Denmark)

    Andersen, Lea Laird; Møller, Lars Alling; Gimbel, Helga Margrethe Elisabeth

    2015-01-01

    OBJECTIVE: To compare subtotal and total abdominal hysterectomy regarding objective assessment of pelvic organ prolapse, urinary incontinence and voiding function 14 years after hysterectomy for benign diseases. STUDY DESIGN: Long-term follow-up of a randomized clinical trial of subtotal vs. total......, total: 100), the PFDI-20 questionnaire was answered by 140 (46.1%) (subtotal: 68, total: 72). We found no difference between subtotal and total abdominal hysterectomy in the PFDI-20 scores or regarding objectively assessed urinary incontinence or pelvic organ prolapse. In the subtotal hysterectomy group...... (443ml) (P=0.0147) according to the voiding diary. CONCLUSION: Subtotal and total abdominal hysterectomy are comparable regarding long-term objective pelvic organ prolapse and urinary incontinence. The subtotal hysterectomy group had a higher Qmax and voided volume....

  5. Subtotal Ablation of Parietal Epithelial Cells Induces Crescent Formation

    Science.gov (United States)

    Sicking, Eva-Maria; Fuss, Astrid; Uhlig, Sandra; Jirak, Peggy; Dijkman, Henry; Wetzels, Jack; Engel, Daniel R.; Urzynicok, Torsten; Heidenreich, Stefan; Kriz, Wilhelm; Kurts, Christian; Ostendorf, Tammo; Floege, Jürgen; Smeets, Bart

    2012-01-01

    Parietal epithelial cells (PECs) of the renal glomerulus contribute to the formation of both cellular crescents in rapidly progressive GN and sclerotic lesions in FSGS. Subtotal transgenic ablation of podocytes induces FSGS but the effect of specific ablation of PECs is unknown. Here, we established an inducible transgenic mouse to allow subtotal ablation of PECs. Proteinuria developed during doxycycline-induced cellular ablation but fully reversed 26 days after termination of doxycycline administration. The ablation of PECs was focal, with only 30% of glomeruli exhibiting histologic changes; however, the number of PECs was reduced up to 90% within affected glomeruli. Ultrastructural analysis revealed disruption of PEC plasma membranes with cytoplasm shedding into Bowman’s space. Podocytes showed focal foot process effacement, which was the most likely cause for transient proteinuria. After >9 days of cellular ablation, the remaining PECs formed cellular extensions to cover the denuded Bowman’s capsule and expressed the activation marker CD44 de novo. The induced proliferation of PECs persisted throughout the observation period, resulting in the formation of typical cellular crescents with periglomerular infiltrate, albeit without accompanying proteinuria. In summary, subtotal ablation of PECs leads the remaining PECs to react with cellular activation and proliferation, which ultimately forms cellular crescents. PMID:22282596

  6. Late follow-up of patients submitted to subtotal splenectomy: late clinical, laboratory, imaging and functional with preservation of the upper splenic pole

    Directory of Open Access Journals (Sweden)

    Andy Petroianu

    2008-09-01

    Full Text Available objective: To evaluate the follow-up of patients submitted to splenectomy with preservation of the upper splenic pole. Methods: All patients undergoing subtotal splenectomy were invited to be reviewed. A total of 86 patients submitted to this surgery were studied. The procedure was performed due to one of the following conditions: portal hypertension due to schistosomiasis (n = 43, trauma (n = 31, Gaucher’s disease (n = 4, myeloid hepatosplenomegaly due to myelofibrosis (n = 3, splenomegalic retarded growth and sexual development (n = 2, severe pain due to splenic ischemia (n = 2 and pancreatic cystadenoma (n = 1. All patients underwent hematologic tests, immunological assessment, abdominal ultrasonography, computed tomography (CT, scintigraphy and endoscopy. Rresults: Increased white blood cell and platelet counts were the only hematological abnormalities. No immune deficit was found. Esophageal varices were still present in patients who underwent surgery because of portal hypertension, but none had a re-bleeding event. The ultrasonography, tomography and scintigraphy confirmed the presence of functional splenic remnants without significant size alteration. Conclusions: Subtotal splenectomy seems to be a safe procedure that can be useful to treat conditions involving the spleen. The functions of the splenic remnants are preserved during long periods of time.

  7. Ultrasonography in trauma

    DEFF Research Database (Denmark)

    Weile, Jesper; Nielsen, Klaus; Primdahl, Stine C

    2017-01-01

    BACKGROUND: The Focused Assessment with Sonography in Trauma (FAST) protocol is considered beneficial in emergent evaluation of trauma patients with blunt or penetrating injury and has become integrated into the Advanced Trauma Life Support (ATLS) protocol. No guidelines exist as to the use...... of ultrasonography in trauma in Denmark. We aimed to determine the current use of ultrasonography for assessing trauma patients in Denmark. METHODS: We conducted a nation-wide cross-sectional investigation of ultrasonography usage in trauma care. The first phase consisted of an Internet-based investigation....... Twenty-one (95.5%) of the guidelines included and recommended FAST as part of trauma assessment. The recommended person to perform the examination was the radiologist in n = 11 (50.0%), the surgeon in n = 6 (27.3%), the anesthesiologist in n = 1 (4.5%), and unspecified in n = 3 (13.6%) facilities. FAST...

  8. Ultrasonography of polycystic kidney

    International Nuclear Information System (INIS)

    Oh, Seung Chul; Cho, Seung Gi; Lee, Kwan Seh; Kim, Kun Sang

    1980-01-01

    Polycystic disease is defined as a heritable disorder with diffuse involvement of both kidneys. The term 'Polycystic disease' comprises at least two separate, genetically different disease-one with an onset typically in childhood (infantile polycystic disease) and the other with an onset typically in adulthood (adult polycystic disease). Adult polycystic kidney disease is the most common form of cystic kidney disease in humans. Ultrasonography is a very useful noninvasive diagnostic modality in the patient with clinically suspected renal diseases as well as screening test. 14 cases of ultrasonography in patient with polycystic kidney were reviewed. All cases show unilateral or bilateral enlarged kidneys. 7 cases reveal kidneys and liver replaced by multiple cysts of varing size. Screening ultrasonography for a familial tree is reported

  9. Ultrasonography of jaundice

    International Nuclear Information System (INIS)

    Cho, Byung Jae; Bae, Sang Hoon; Lee, Seung Ro; Kim, Chu Wan

    1980-01-01

    The importance of ultrasonography in the evaluation of jaundice is stressed with an analysis of 47 cases of jaundice. 31 cases proved to be obstructive and 16 non-obstructive jaundice. Obstructive jaundice could be differentiated from non-obstructive jaundice in all but 2 cases, (96%). The site of obstruction in 31 cases of obstructive jaundice could be predicted correctly in 23 cases of 31, (90%), and cause of obstruction with an accuracy of 35% as well. One can certainly recommend ultrasonography as an initial procedure of choice in jaundice patients

  10. Ultrasonography in abdominal emergencies

    International Nuclear Information System (INIS)

    Risi, D.; Alessi, G.; Meli, C.; Marzano, M.; Fiori, E.; Caterino, S.

    1989-01-01

    From February 1986 to March 1988 113 abdominal US exams were performed in emergency situation to evaluate the accuracy of this methodology: 13 were blunt traumas, 18 post-operative complications. A real-time scanner with a linear probe of 5 MHz was employed. The results were confirmed by surgical and/or clinical and instrumental evaluation. In 81% of the examinations, ultrasonography allowed a diagnosis to be made. Gallbladder and biliary pathologies were the most common findings. The results (sensibility 96%, specificity 88%, accuracy 95%) confirm the affidability of ultrasonography in abdominal emergencies, as shown in literature

  11. Ultrasonography X gamma radiography

    International Nuclear Information System (INIS)

    Mello Campos, A.M. de

    1989-01-01

    The accumulated experience in the last ten years of substitution to essays by gamma radiography to essay by ultrasonography, starting of the systematic comparison and tabulation of the results obtained by both essays applied in welding joints, in field, in steel pipelines of the SABESP. (V.R.B.)

  12. Surgeon-performed ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias

    2017-01-01

    Surgeons are increasingly using ultrasonography (US) in their clinical management of patients. However, US is a very user-dependent imaging modality and proper skills of the US operator are needed to ensure quality in patient care. This thesis explores the validity evidence for assessment...

  13. Ultrasonography of the Kidney

    DEFF Research Database (Denmark)

    Lindskov Hansen, Kristoffer; Nielsen, Michael Bachmann; Ewertsen, Caroline

    2016-01-01

    Ultrasonography of the kidneys is essential in the diagnosis and management of kidney-related diseases. The kidneys are easily examined, and most pathological changes in the kidneys are distinguishable with ultrasound. In this pictorial review, the most common findings in renal ultrasound...

  14. Successful subtotal orbitectomy in a cat with osteoma

    Directory of Open Access Journals (Sweden)

    Katia B Corgozinho

    2015-11-01

    Full Text Available Case summary A 14-year-old Siamese neutered male cat was evaluated for anorexia and a left periorbital mass. Skull radiographic findings showed a well-defined lesion resembling new compact bone formation without destruction. A subtotal orbitectomy was indicated. The tumor was removed intact with a normal tissue margin of at least 1 cm. There were no postsurgical complications. Histopathologic examination revealed an osteoma. The cat returned to normal appetite and activity 15 days after surgery. Six months after surgery, there were no gross signs of recurrence. Relevance and novel information Periorbital tumors are infrequently diagnosed in companion animals and most are malignant. In this case, the diagnosis was orbital osteoma. The most commonly affected bone for osteoma in cats is the mandibular bone; few cases have been identified in orbital bones. Orbital surgery has the potential to be challenging owing to complex anatomy, difficult exposure and the tendency to bleed. Surgical complications are common. In this case, although the disease was advanced, subtotal orbitectomy was successfully performed.

  15. Ultrasonography in Obstertrics

    International Nuclear Information System (INIS)

    Lee, Hyon U.

    1982-01-01

    The usefulness of pulse-echo ultrasonography of the practices of obstetrics has been great. It is more reliable than many biochemical and biophysical technics that have been developed in recent years to try to improve pregnancy outcome. When carefully performed and accurately interpreted, it can supply most vital information about the status of the fetus without any known risks to both mother and the fetus itself. The main obstertricalindications of ultrasonography coule be summarized as follows. 1. Diagnosis of early pregnancy. 2. Fetal growth and its maturity. 3. Complications of pregnancy and abnormal pregnancy. a) Vaginal bleeding in early intrauterinepregnancy. b) Multiple pregnancy. c) Ectopic pregnancy d) Hydatidiform mole e) Pelvic mass complicated with pregnancy f) Fetal anomaly 4. Fetal presenation and attitude 5. Placentography

  16. Obstructive Left Colon Cancer Should Be Managed by Using a Subtotal Colectomy Instead of Colonic Stenting

    Science.gov (United States)

    Min, Chung Ki; Lee, Donghyoun; Jung, Kyung Uk; Lee, Sung Ryol; Kim, Hungdai; Chun, Ho-Kyung

    2016-01-01

    Purpose This study compared a subtotal colectomy to self-expandable metallic stent (SEMS) insertion as a bridge to surgery for patients with left colon-cancer obstruction. Methods Ninety-four consecutive patients with left colon-cancer obstruction underwent an emergency subtotal colectomy or elective SEMS insertion between January 2007 and August 2014. Using prospectively collected data, we performed a retrospective comparative analysis on an intention-to-treat basis. Results A subtotal colectomy and SEMS insertion were attempted in 24 and 70 patients, respectively. SEMS insertion technically failed in 5 patients (7.1%). The mean age and rate of obstruction in the descending colon were higher in the subtotal colectomy group than the SEMS group. Sex, underlying disease, American Society of Anesthesiologists physical status, and pathological stage showed no statistical difference. Laparoscopic surgery was performed more frequently in patients in the SEMS group (62 of 70, 88.6%) than in patients in the subtotal colectomy group (4 of 24, 16.7%). The overall rate of postoperative morbidity was higher in the SEMS group. No Clavien-Dindo grade III or IV complications occurred in the subtotal colectomy group, but 2 patients (2.9%) died from septic complications in the SEMS group. One patient (4.2%) in the subtotal colectomy group had synchronous cancer. The total hospital stay was shorter in the subtotal colectomy group. The median number of bowel movements in the subtotal colectomy group was twice per day at postoperative 3–6 months. Conclusion A subtotal colectomy for patients with obstructive left-colon cancer is a clinically and oncologically safer, 1-stage, surgical strategy compared to SEMS insertion as a bridge to surgery. PMID:28119864

  17. Lower urinary tract symptoms after total and subtotal hysterectomy

    DEFF Research Database (Denmark)

    Gimbel, Helga; Zobbe, Vibeke; Andersen, Birthe Jakobsen

    2005-01-01

    The aim of this Danish multicenter trial was to compare the proportion of women with lower urinary tract symptoms after total abdominal hysterectomy (TAH) and subtotal abdominal hysterectomy (SAH) for benign uterine disorders. A total of 319 women were randomized to TAH (n = 158) or SAH (n = 161......). Women were followed up for 1 year by strict data collection procedures, including postal questionnaires. Results were analyzed by intention-to-treat analyses. Urinary incontinence was found less often among TAH women than among SAH women. This was due to a larger reduction of the number of women...... with stress and urinary incontinence in the TAH group. No other differences were found between the two operation methods. The number of women with urinary incontinence and frequency was reduced from study entry for follow-up, while double/triple voiding was increased. Incontinent women had significantly lower...

  18. Management of chronic otitis media by subtotal petrosectomy.

    Science.gov (United States)

    Altuna, Xabier; Navarro, Juan José; Goiburu, Miren; Palicio, Idoia

    2016-01-01

    Subtotal petrosectomy is the complete exenteration of all air cell tracts of the temporal bone. The isthmus of the Eustachian tube is obliterated and the external auditory canal is closed. The aim of this study was to describe the use of this technique in the management of certain cases of chronic otitis media. We conducted a retrospective revision of the patients treated in our Institution with this technique for chronic otitis media in a 5-year period (2008-2012). All charts were reviewed and data from the otomicroscopy, audiometry, radiology, surgical findings, postoperative complications and follow-up (including diffusion magnetic resonance imaging, MRI) of a minimum of 24 months were collected. In this period petrosectomy was performed on 28 patients for chronic otitis media. We treated 13 cases as primary cases, while 15 cases were secondary (patients that had already undergone another procedure in that ear). Fifteen cases had no serviceable hearing. Only 1 case had an immediate postoperative complication (infection); during the posterior follow-up, 2 cases had to be reoperated for diffusion restriction in the mastoid area revealed in the MRI 2 years after surgery. A subtotal petrosectomy is rarely performed for the treatment of chronic otitis media. However, it is a technique that we have to keep in mind for the treatment of certain cases where there is recurrence and deep hearing loss, as well as in cases with good cochlear reserve if the disease coexists with other complications. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  19. SUBTOTAL THYROIDECTOMY IN THE MANAGEMENT OF GRAVE'S DISEASE.

    Science.gov (United States)

    Vincent, P J; Garg, M K; Singh, Y; Bhalla, V P; Datta, S

    2001-07-01

    Treatment options for Grave's disease include radio-iodine ablation, which is the standard treatment in the USA, antithyroid drug therapy, which is popular in Japan, and surgery, which is commonly employed in Europe and India. There are very few reports about the outcome of surgery in Grave's disease in the Indian setting. Surgery for Grave's disease is an attractive option in under developed countries to cut short prolonged drug treatment, costly follow up and avoid the need for radio-isotope facilities for 1311 ablation. Aim of the present study was to assess the result of subtotal thyroidectomy in 32 cases of Grave's Disease referred for surgery by the endocrinologist in a teaching hospital. Patients were prepared for surgery with Lugol's iodine and propranalol. Subtotal thyroidectomy was performed by a standard technique, which included dissection and exposure of recurrent laryngeal nerves and parathyroid glands. Actual estimation of weight of the remnant gland was not part of the study. Duration of follow up ranged from 6 months to 4 years. 13 of 32 cases were males. Age ranged from 20 to 57 years. There was 1 death in the immediate post-operative period. There were no cases of permanent hypoparathyroidism or recurrent laryngeal nerve palsy. 1 patient developed temporary hypoparathyroidism. 1 patient developed recurrence of hyperthyroidism and 3 cases developed hypothyroidism all within 2 years of surgery. The study has demonstrated the safety and effectiveness of surgery for Grave's Disease in comparison to the reported high incidence of hypothyroidism following radio-iodine therapy and high recurrence rate after anti thyroid drug therapy.

  20. Ultrasonography of Neonatal Cholestasis

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, Jung Eun [Seoul National University Hospital, Seoul (Korea, Republic of)

    2012-06-15

    Ultrasonography (US) is as an important tool for differentiation of obstructive and non-obstructive causes of jaundice in infants and children. Beyond two weeks of age, extrahepatic biliary atresia and neonatal hepatitis are the two most common causes of persistent neonatal jaundice: differentiation of extrahepatic biliary atresia, which requires early surgical intervention, is very important. Meticulous analysis should focus on size and configuration of the gallbladder and anatomical changes of the portahepatis. In order to narrow the differential diagnosis, combined approaches using hepatic scintigraphy, MR cholangiography, and, at times, percutaneous liver biopsy are necessary. US is useful for demonstrating choledochal cyst, bile plug syndrome, and spontaneous perforation of the extrahepatic bile duct

  1. Ultrasonography of ovarian hyperandrogenemia

    Science.gov (United States)

    Kuzmina, Svetlana A.; Zharkin, Nikolay A.

    2001-05-01

    The method of ultrasonography is high informative and widely used in diagnostics of ovarian hyperandrogenaemia. The majority of authors consider that a hyperplasia of a stroma is the main pathognomonic marker of polycystic ovaries (PCO). Still recently swell of a stroma was valued visually, that had subjective nature. We offer for the first time a way of diagnostics of stromal hyperplasia grounded on measurement of a volume of a stroma and ovary with ultrasound method, calculation of the ratio of a volume of the ovary to a volume of a stroma for every patient.

  2. Ultrasonography in gastroenterology.

    Science.gov (United States)

    Ødegaard, Svein; Nesje, Lars B; Hausken, Trygve; Gilja, Odd Helge

    2015-06-01

    Ultrasonography (US) is a safe and available real-time, high-resolution imaging method, which during the last decades has been increasingly integrated as a clinical tool in gastroenterology. New US applications have emerged with enforced data software and new technical solutions, including strain evaluation, three-dimensional imaging and use of ultrasound contrast agents. Specific gastroenterologic applications have been developed by combining US with other diagnostic or therapeutic methods, such as endoscopy, manometry, puncture needles, diathermy and stents. US provides detailed structural information about visceral organs without hazard to the patients and can play an important clinical role by reducing the need for invasive procedures. This paper presents different aspects of US in gastroenterology, with a special emphasis on the contribution from Nordic scientists in developing clinical applications.

  3. Musculoskeletal ultrasonography in children

    International Nuclear Information System (INIS)

    Teo, E.-L.H.; Strouse, P.J.; Chhem, R.K.

    2002-01-01

    With the development of high-resolution ultrasound transducers, the role of ultrasonography (US) in evaluating the musculoskeletal system has increased. It is now possible to obtain detailed images of bones and soft-tissue structures that were previously unattainable. The advantages of US, when compared with other imaging modalities, are many. It is less expensive than magnetic resonance imaging (MRI) and computed tomography (CT). It does not expose the patient to ionizing radiation, so US examinations can be repeated without harm to the patient. Furthermore, US is performed in real-time, making it possible to assess the musculoskeletal system dynamically, in multiple planes and with contralateral comparison. In experienced hands, US is a quick, noninvasive and cost-effective way to assess the musculoskeletal system in children. It is used to evaluate soft-tissue masses, joint swelling, infections, lesions involving the chest and abdominal walls, bones, muscles and clubfoot deformity and to locate any foreign bodies. (author)

  4. Subtotal splenectomy preserving the inferior splenic pole for the treatment of Hodgkin’s lymphoma

    Directory of Open Access Journals (Sweden)

    Andy Petroianu

    2017-01-01

    Conclusion: Subtotal splenectomy is efficacious to preserve the splenic functions and to prevent adverse effects of a large spleen on the treatment of Hodgkin’s lymphoma confined to superior pole and producing significant abdominal symptoms and hematological effects.

  5. [Measurements of tibio-femoral contact area after experimental partial and subtotal meniscectomie (author's transl)].

    Science.gov (United States)

    Hehne, H J; Riede, U N; Hauschild, G; Schlageter, M

    1981-02-01

    By means of section material, 24 partial and 58 subtotal meniscectomies were performed and the loss of tibio-femoral contact was evaluated by the Touchier-method planimetrically. In cases of partial resection this loss was 12% only, where as in subtotal resection 46%, where by the remaining contact zones lay in the central-, anyway meniscusfree area. The diagram of the chondral splitting lines showed a maximum of compression here, consecutively the remaining contact zone is reduced to the in earlier times most affected cartilage areas. The result correlates to the appearance of chondromalacies of the central tibial plateau in our own section cases and of postoperative osteoarthritis after subtotal meniscectomies in literature. Subtotal meniscectomies lead to incongruence and increased pressure. a pseudo-regeneration seems not to compensate the meniscus function sufficiently. A result for the clinic one should, when possible, resect menisci only partially.

  6. Laparoscopic subtotal hysterectomy in the era of minimally invasive surgery

    Directory of Open Access Journals (Sweden)

    Chia-Jen Wu

    2015-02-01

    Full Text Available According to a nation-wide population-based study in Taiwan, along with the expanding concepts and surgical techniques of minimally invasive surgery, laparoscopic supracervical/subtotal hysterectomy (LSH has been blooming. Despite this, the role of LSH in the era of minimally invasive surgery remains uncertain. In this review, we tried to evaluate the perioperative and postoperative outcomes of LSH compared to other types of hysterectomy, including total abdominal hysterectomy (TAH, vaginal hysterectomy, laparoscopic-assisted vaginal hysterectomy, and total laparoscopic hysterectomy (TLH. From the literature, LSH has a better perioperative outcome than TAH, and comparable perioperative complications compared with laparoscopic-assisted vaginal hysterectomy. LSH had less bladder injury, vaginal cuff bleeding, hematoma, infection, and dehiscence requiring re-operation compared with TLH. Despite this, LSH has more postoperative cyclic menstrual bleeding and re-operations with extirpations of the cervical stump. LSH does, however, have a shorter recovery time than TAH due to the minimally invasive approach; and there is quicker resumption of coitus than TLH, due to cervical preservation and the avoidance of vaginal cuff dehiscence. LSH is therefore an alternative option when the removal of the cervix is not strictly necessary or desired. Nevertheless, the risk of further cervical malignancy, postoperative cyclic menstrual bleeding, and re-operations with extirpations of the cervical stump is a concern when discussing the advantages and disadvantages of LSH with patients.

  7. Surgeon-performed ultrasonography.

    Science.gov (United States)

    Todsen, Tobias

    2017-11-01

    Surgeons are increasingly using ultrasonography (US) in their clinical management of patients. However, US is a very user-dependent imaging modality and proper skills of the US operator are needed to ensure quality in patient care. This thesis explores the validity evidence for assessment of competence in abdominal and head & neck ultrasonography using the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale. With the use of Messick's unitary framework of validity, five sources of validity evidence were explored: test content, response processes, inter-nal structure, relations to other variables, and consequences. Research paper I examined validity evidence for the use of the OSAUS scale to assess physicians' abdominal point-of-care US competence in an experimental setting using patient cases with and without pathological conditions. The RESULTS provided validity evidence of the internal structure of the OSAUS scale and a deci-sion study predicted that four cases and two raters or five cases and one rater could ensure sufficient reliability in future test setups. The relation to other variables was supported by a signifi-cant difference in scores between US experience levels, and by a strong correlation between the OSAUS score and diagnostic accuracy. Research paper II explored the transfer of learning from formal point-of-care US training to performance on patients in a randomized controlled study. The RESULTS supported validity evi-dence regarding OSAUS scores' relation to other variables by demonstrating a significant discrimination in the progress of training-a more refined validity evidence than the relation to difference experience levels. The RESULTS showed that physicians could transfer the skills learned on an ultrasonography course to improved US performance and diagnostic accuracy on patients. However, the RESULTS also indicated that following an initial course, additional training is needed for physicians to achieve competence in US

  8. Transthoracic Ultrasonography for Clinicians

    Directory of Open Access Journals (Sweden)

    Morné Johan Vorster

    2015-04-01

    Full Text Available Transthoracic ultrasonography (US has become an essential tool for respiratory, emergency, and critical care physicians. It can be performed with basic equipment and by personnel with minimum training as a modality for the evaluation of a wide range of thoracic pathologies. Its advantages include immediate application at the point of care, low cost, and lack of radiation. The main indications for transthoracic US are the qualitative and quantitative assessment of pleural effusions, pleural thickening, diaphragmatic pathology, as well as chest wall and pleural tumors. Transthoracic US is also useful in visualizing pulmonary pathologies that abut the pleura, such as pneumonic consolidation and interstitial syndromes, including pulmonary edema. Transthoracic US is more sensitive than the traditional chest radiograph in the detection of pneumothoraces, and it is useful in diagnosing skeletal abnormalities such as rib fractures. It is the ideal tool to guide transthoracic procedures, including thoracocentesis and pleural biopsy. Moreover, transthoracic US-guided procedures can be performed by a single clinician with no sedation and minimal monitoring. Transthoracic US-guided fine needle aspiration and/or cutting needle biopsy of extrathoracic lymph nodes and lesions arising from the chest wall, pleura, peripheral lung, and mediastinum are safe to perform and have a high yield in the of hands of experienced clinicians. Transthoracic US can also potentially guide the aspiration and biopsy of diffuse pulmonary infiltrates, consolidations, and lung abscesses. Moreover, transthoracic US may be used in the detection of pulmonary embolism

  9. Advances in diagnostic ultrasonography.

    Science.gov (United States)

    Reef, V B

    1991-08-01

    A wide variety of ultrasonographic equipment currently is available for use in equine practice, but no one machine is optimal for every type of imaging. Image quality is the most important factor in equipment selection once the needs of the practitioner are ascertained. The transducer frequencies available, transducer footprints, depth of field displayed, frame rate, gray scale, simultaneous electrocardiography, Doppler, and functions to modify the image are all important considerations. The ability to make measurements off of videocassette recorder playback and future upgradability should be evaluated. Linear array and sector technology are the backbone of equine ultrasonography today. Linear array technology is most useful for a high-volume broodmare practice, whereas sector technology is ideal for a more general equine practice. The curved or convex linear scanner has more applications than the standard linear array and is equipped with the linear array rectal probe, which provides the equine practitioner with a more versatile unit for equine ultrasonographic evaluations. The annular array and phased array systems have improved image quality, but each has its own limitations. The new sector scanners still provide the most versatile affordable equipment for equine general practice.

  10. Transvaginal ultrasonography of rectal endometriosis

    DEFF Research Database (Denmark)

    Egekvist, Anne Gisselmann; Seyer-Hansen, Mikkel; Forman, Axel

    Objectives: The aim of this present study was to evaluate the interobserver variation of transvaginal ultrasonographic measurements of endometriosis infiltrating the rectosigmoid wall. Methods: Transvaginal ultrasonography was performed independently by two observers. Observer 1 had several years...... of experience in ultrasonography while observer 2 was a medical student with no prior experience in ultrasonography or endometriosis. In 24 patient length, width and depth of endometriosis infiltrating the rectosigmoid bowel was measured. The differences between the observers were analysed by Bland and Altman...... for a relatively short period gives comparable scanning results between the two observers. It seems that transvaginal ultrasound could be used as a diagnostic tool for rectal endometriosis in most departments. However, the irregular morphology of the lesions makes the measurements very complex, and a strict...

  11. Ultrasonography of the equine shoulder

    International Nuclear Information System (INIS)

    Dik, K.J.

    1996-01-01

    Six horses with shoulder injuries were presented in this report with emphasis on the use of ultrasonography vs. radiography in diagnosis. The two imaging modalities represented valuable and complementary diagnostic procedures. Two horses had fracture fragments of the lateral humeral tuberosity, the accurate ultrasonographic findings encouraging clearer radiographic identification by oblique projections. In one horseultrasonography enabled more accurate localization of calcification within the supraspinatus muscle. In the remaining three cases ultrasonography visualized distension of the bicipital bursa due to aseptic bursitis, bursal hemorrhage, or associated with injury of the biceps brachii muscle and the underlying intermediate humeral tubercle, the bony involvement more clearly demonstrated radiographically

  12. A case of early recurred tentorial meningioma after subtotal removal and postoperative radiation

    International Nuclear Information System (INIS)

    Kim, Han Sik; Kim, Young Baeg; Kim, Mi Kyung; Hwang, Sung Nam; Suk, Jong Sik; Choi, Duck Young

    1995-01-01

    Postoperative radiation has been given to prevent or delay recurrence of subtotally resected meningioma in recent years. However, the authors experienced early recurred tentorial meningioma 10 months after subtotal resection and postoperative radiation. This 70-year-old man was found to have a large stradling mass on the left petrous pyramid, extending to the middle fossa and cerebellopontine angle(CPA). A subtotal resection was performed at initial surgery, remaining some residual tumor along the lateral tentorium and he received 5580 Gy of radiation over the following 5 weeks. He did well until 10 months after the irradiation, when he presented with left mastoid pain, facial palsy, and left hearing loss. MRI confirmed recurrence of tumor and gross total tumor resection was performed via presigmoid retrolabyrinthine approach. The histology of the recurrent tumor was basically identical with that of the primary lesion, except for the slightly increased celluarity and mild pleomorphism

  13. A long-term follow-up study of subtotal splenectomy in children with hereditary spherocytosis.

    Science.gov (United States)

    Rosman, C W K; Broens, P M A; Trzpis, M; Tamminga, R Y J

    2017-10-01

    Hereditary spherocytosis (HS) is a heterogeneous hemolytic anemia treated with splenectomy in patients suffering from severe or moderate disease. Total splenectomy, however, renders patients vulnerable to overwhelming postsplenectomy infection despite preventive measures. Although subtotal splenectomy has been advocated as an alternative to total splenectomy, long-term follow-up data are scarce. We investigated how often hematologic recurrences requiring secondary total splenectomy occurred. With a follow-up of at least 5 years, we analyzed the data of 12 patients, aged 11 years maximum (median 6.5 years), who had undergone intended subtotal splenectomy, and 9 patients (median age 11.9 years), who had undergone total splenectomy. We compared their hematologic results and searched for factors associated with secondary spleen surgery. Hemolysis was reduced after subtotal splenectomy and absent after total splenectomy. Subtotal splenectomy was not successful in three children because no functional splenic remnant remained after 6 months (one conversion at surgery; one necrosis of splenic remnant; one early secondary splenectomy). Four children required secondary splenectomy after a median of 5 years for hematologic recurrence. In the remaining five patients, a functional splenic remnant was present for at least 5.5 years. The median time to secondary total splenectomy after intended subtotal splenectomy was 5.2 years. In all patients requiring secondary total splenectomy, increased reticulocyte levels within 2 years indicated hematologic recurrence. Subtotal splenectomy can be an alternative for total splenectomy in young patients with HS. It allows for hematologic improvement and may preserve splenic immune function for as many as 5 years. © 2017 Wiley Periodicals, Inc.

  14. Ultrasonography of the Rotator Cuff

    International Nuclear Information System (INIS)

    Yoon, Yong Cheol

    2006-01-01

    The ultrasonography (US) is an important modality in evaluating shoulder disease. It is accurate in diagnosing the various shoulder diseases including tendinosis, calcific tendinitis, and subacromial bursitis as well as rotator cuff tears. This article presents a pictorial review of US anatomy of the shoulder, the technical aspects of shoulder US, major types of shoulder pathology, and interventional procedure under US guidance

  15. Ultrasonography of the Rotator Cuff

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yong Cheol [Samsung Medica Center, Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of)

    2006-09-15

    The ultrasonography (US) is an important modality in evaluating shoulder disease. It is accurate in diagnosing the various shoulder diseases including tendinosis, calcific tendinitis, and subacromial bursitis as well as rotator cuff tears. This article presents a pictorial review of US anatomy of the shoulder, the technical aspects of shoulder US, major types of shoulder pathology, and interventional procedure under US guidance

  16. Laparoscopic and open subtotal colectomies have similar short-term results

    NARCIS (Netherlands)

    Hoogenboom, Froukje J.; Bosker, Robbert J. I.; Groen, Henk; Meijerink, Wilhelmus J. H. J.; Lamme, Bas; Pierie, Jean Pierre E. N.

    2013-01-01

    Background: Laparoscopic subtotal colectomy (STC) is a complex procedure. It is possible that short-term benefits for segmental resections cannot be attributed to this complex procedure. This study aims to assess differences in shortterm results for laparoscopic versus open STC during a 15year

  17. Subtotal body irradiation with linear accelerator as preparation for marrow engraftment in aplastic anemia

    International Nuclear Information System (INIS)

    Walbom-Joergensen, S.; Ernst, P.

    1979-01-01

    Two cases of multitransfused severe aplastic anemia were retransplanted with bone marrow from the same HLA compatible sibling donors after subtotal body irradiation (800 r). Only minor non hematologic toxicity was observed. No permanent take was seen in relation to this procedure. During the survival time of the patients (78-120 days) no signs of interstitial pneumonia were observed

  18. Laparoscopic cholecystectomy in cirrhotic patients: the role of subtotal cholecystectomy and its variants.

    Science.gov (United States)

    Palanivelu, Chinnasamy; Rajan, Pidigu Seshiyer; Jani, Kalpesh; Shetty, Alangar Roshan; Sendhilkumar, Karuppasamy; Senthilnathan, Palanisamy; Parthasarthi, Ramakrishnan

    2006-08-01

    Open cholecystectomy is associated with considerable morbidity and mortality in cirrhotic patients. Laparoscopic cholecystectomy may offer a better option because of the magnification available and the availability of newer instruments like the ultrasonic shears. We present our experience of 265 laparoscopic cholecystectomies and attempt to identify the difficulties encountered in this group of patients. Between 1991 and 2005, 265 cirrhotic patients of Child-Pugh Classification A and B, with symptomatic gallstones, were subjected to laparoscopic cholecystectomy. We describe here our tailored approach and our techniques of subtotal cholecystectomy. Features of acute cholecystitis were present in 35.1% of the patients, and 64.9% presented with chronic cholecystitis. In 81.5% of the patients, the diagnosis of cirrhosis was established preoperatively. In 8.3% of the patients, a fundus first method was adopted when the hilum could not be approached despite additional ports. Modified subtotal cholecystectomy was performed in a total of 206 patients. Mean operative time in the subtotal cholecystectomy group was 72 minutes; in the standard group, it was 41 minutes. There was no mortality. In 15% of patients, postoperative deterioration in liver function occurred. Worsening of ascites, port site infection, port site bleeding, intraoperative hemorrhage, bilious drainage, and stone formation in the remnant were the other complications encountered. Laparoscopic cholecystectomy is a safe and effective treatment for calculous cholecystitis in cirrhotic patients. Appropriate modification of subtotal cholecystectomy should be practiced, depending on the risk factors present, to avoid complications.

  19. Acceptable short-term outcome of laparoscopic subtotal colectomy for inflammatory bowel disease

    DEFF Research Database (Denmark)

    Frid, Natalie Lassen; Bulut, Orhan; Pachler, Jørn

    2013-01-01

    Laparoscopic colectomy for both benign and malignant disease, including inflammatory bowel disease (IBD), has recently been shown to have many advantages compared with open surgery. This study aimed to compare the effect of laparoscopic versus open subtotal colectomy (STC) for IBD on overall...

  20. Uterine Perforation With Subtotal Small Bowel Prolapse – A Rare Complication of Dilatation and Curettage

    Directory of Open Access Journals (Sweden)

    Jagannath Mala Sherigar

    2005-05-01

    Full Text Available Uterine perforation is the well known complication of induced abortion. We report a rare case of uterine perforation with subtotal prolapse of small bowel following first trimester abortion by an unqualified physician. Early surgical exploration with resection and anastomosis of bowel performed. Patient discharged uneventfully after postoperative recovery.

  1. Diagnostic nerve ultrasonography; Diagnostische Nervensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Baeumer, T. [Universitaet zu Luebeck CBBM, Haus 66, Institut fuer Neurogenetik, Luebeck (Germany); Grimm, A. [Universitaetsklinikum Tuebingen, Klinik und Poliklinik fuer Neurologie, Tuebingen (Germany); Schelle, T. [Staedtisches Klinikum Dessau, Neurologische Klinik, Dessau (Germany)

    2017-03-15

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [German] Fuer die Diagnostik von Nervenlaesionen ist ein bildgebendes Verfahren zur Darstellung des peripheren Nervs und seiner ihn umgebenden Strukturen fuer eine aetiologische Einordnung erforderlich. Mit der klinisch-neurologischen Untersuchung und Elektrophysiologie ist eine funktionelle Aussage ueber die Nervenlaesion moeglich. In der Standard-MRT-Untersuchung wird der periphere Nerv nur unzureichend gut dargestellt. Die MRT-Neurographie ist ein sehr gutes, aber auch zeit- und ressourcenintensives Verfahren. Nutzung des Ultraschalls fuer die

  2. Acid Secretion and Its Relationship to Esophageal Reflux Symptom in Patients with Subtotal Gastrectomy.

    Science.gov (United States)

    Oh, Hyun Jin; Choi, Myung-Gyu; Park, Jae Myung; Song, Kyo Young; Yoo, Han Mo

    2018-03-01

    Esophageal reflux symptom has been reported as common in patients with subtotal gastrectomy. Management of postoperative esophageal reflux symptom is not satisfactory. The aim of this study is to investigate prevalence of esophageal reflux symptom after subtotal gastrectomy and assess factors affecting esophageal reflux symptom in subtotal gastrectomy patients. We prospectively enrolled 100 consecutive patients with subtotal gastrectomy who were regularly followed up by endoscopic examination. Acid secretory capacity was assessed by measuring messenger RNA (mRNA) expression of H + /K + -adenosine triphosphatase (ATPase) via real-time polymerase chain reaction (PCR) in biopsy specimens. In total, 47 % of patients had typical esophageal reflux symptom, where heartburn or regurgitation was experienced at least weekly. Age, sex, body mass index, and type of reconstruction did not differ between esophageal reflux and non-esophageal-reflux groups. The esophageal reflux group had longer duration from time of operation until study (median 5.0 versus 3.6 years; P = 0.017). Hill grade for gastroesophageal (GE) flap valve was higher in the esophageal reflux group than in the non-esophageal-reflux group (P = 0.027). H + /K + -ATPase mRNA expression was higher in the esophageal reflux group than in the non-esophageal-reflux group [3967.6 (± 7583.7) versus 896.2 (± 1456.0); P = 0.006]. Multivariate analysis revealed that postoperative duration, H + /K + -ATPase mRNA expression level, and GE flap valve disruption were significantly associated with esophageal reflux symptom development. Esophageal reflux symptom is common in patients after subtotal gastrectomy, possibly because of anti-reflux-barrier impairment and preservation of acid secretory capacity following surgery. Optimal acid suppression may be helpful in managing postoperative esophageal reflux symptom.

  3. Ultrasonography of the canine pancreas

    Directory of Open Access Journals (Sweden)

    Michelle L Avante

    2018-01-01

    Full Text Available This study describes the ultrasonographic techniques currently used in the evaluation of the canine pancreas. Ultrasonography was the first method to enable direct visualization of the pancreas in humans and it has been subsequently applied to animals. Currently, it is the method of choice for pancreatic evaluation and is essential as a diagnostic tool in the detection of abnormalities, especially tumors. Innovative equipment technology has led to the emergence of techniques complementary to B-mode ultrasound; such as Doppler, elastography, and contrast-enhanced ultrasonography, which have enabled more accurate diagnosis. Doppler provides information on vascular architecture and the hemodynamic aspect of blood vessels in multiple organs. ARFI elastography provides detailed images of the alterations detected by conventional examination (qualitative method and assists in differentiating between benign and malignant processes (quantitative method. Microbubble contrast agents determine parameters related to homogeneous and heterogeneous filling of organs with microbubbles, mainly nodular areas, thus defining high and low intensity patterns.

  4. Ultrasonography findings of gastric carcinoma

    International Nuclear Information System (INIS)

    Chung, Chong Ku; Choi, Ji Bai; Ko, Young Tae; Lim, Jae Hoon; Kim, Soon Young

    1985-01-01

    Stomach carcinoma is more common disease in Korea than western countries. The reported ultrasonographic findings of gastric carcinoma were thickening of gastric wall and 'pseudokidney' sign. The author analyzed ultrasonographic findings of 101 cases with gastric carcinoma who were performed ultrasonography and gastroscopy at Kyung Hee University Hospital from October 1982 to October 1985. The results were as followings; 1. Types of gastric carcinoma were consisted with infiltrative type 68 cases, infiltrative type with ulceration 16 cases, polypoid type with ulceration 1 case, infiltrative adn polypoid type 4 cases, limits plastica type 3 cases, ulcerative type 1 case and polypoid type 1 case. 2. Extent of the lesions were in body and antrum 45 cases, entire stomach 18 cases, antrum 18 cases, body 12 cases, body and fundus 6 cases. 3. Ultrasonography was useful in demonstrating the extent of the tumor and the presence of materials elsewhere in abdomen

  5. Ultrasonography findings of gastric carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Chong Ku; Choi, Ji Bai; Ko, Young Tae; Lim, Jae Hoon; Kim, Soon Young [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1985-12-15

    Stomach carcinoma is more common disease in Korea than western countries. The reported ultrasonographic findings of gastric carcinoma were thickening of gastric wall and 'pseudokidney' sign. The author analyzed ultrasonographic findings of 101 cases with gastric carcinoma who were performed ultrasonography and gastroscopy at Kyung Hee University Hospital from October 1982 to October 1985. The results were as followings; 1. Types of gastric carcinoma were consisted with infiltrative type 68 cases, infiltrative type with ulceration 16 cases, polypoid type with ulceration 1 case, infiltrative adn polypoid type 4 cases, limits plastica type 3 cases, ulcerative type 1 case and polypoid type 1 case. 2. Extent of the lesions were in body and antrum 45 cases, entire stomach 18 cases, antrum 18 cases, body 12 cases, body and fundus 6 cases. 3. Ultrasonography was useful in demonstrating the extent of the tumor and the presence of materials elsewhere in abdomen.

  6. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncica, Ana Maria; Saftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...

  7. Abdominal ultrasonography, 2nd Ed

    International Nuclear Information System (INIS)

    Goldberg, B.B.

    1984-01-01

    This volume is a new and updated edition of an extensively illustrated text and reference on the capabilities and imaging of gray scale ultrasonography for each major abdominal organ. Each major organ system is treated separately, including liver, gallbladder and bile ducts, pancreas, kidney, retroperitoneum, abdominal vasculature, and more. There are over 500 illustrations and ten pages of full color plates for cross sectional anatomy

  8. Thyroid ultrasonography: Pitfalls and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seon hyeong; Kim, Eun Kyung; Kim, Soo Jin; Kwak, Jin Young [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-04-15

    Thyroid ultrasonography (US) plays a key role in the diagnosis and management of thyroid-related diseases. The aim of this article was to illustrate various pitfalls that can occur in utilizing thyroid US and techniques to prevent them. In this article, we present cases demonstrating the common pitfalls associated with US equipment, performance, normal thyroid structures, misinterpretations, and surrounding structures. Knowledge of these areas is essential to avoid misdiagnosis or improper disease management.

  9. The importance of the ligation of the inferior thyroid artery in parathyroid function after subtotal thyroidectomy

    Directory of Open Access Journals (Sweden)

    Araujo Filho Vergilius José Furtado de

    2000-01-01

    Full Text Available We prospectively studied the effects of the ligation of the inferior thyroid artery (ITA on postoperative hypoparathyroidism in 48 patients who underwent functional subtotal thyroidectomy. Patients were randomized into two groups: A, with bilateral ligation of the ITA and B, without ligation of the ITA. Parathyroid function was checked preoperatively and after surgery by clinical examination and measurement of total calcium, intact PTH, urinary calcium, and AMPc. RESULTS: A significant incidence of postoperative hypocalcemia occurred: 17% in group A and 13% in B on the 4th postoperative day. Six months later, the incidence was 5% in Group A and 0% in Group B. These differences were not statistically significant between the two groups, and neither were any of the other clinical and laboratory observations. CONCLUSION: The ligation of the ITA was not an important causal factor for the occurrence of postoperative hypocalcemia after subtotal thyroidectomy.

  10. Laparoscopic subtotal colectomy with transrectal extraction of the colon and ileorectal anastomosis.

    Science.gov (United States)

    Awad, Ziad T

    2012-03-01

    Despite the growing acceptance of laparoscopic colon surgery, an abdominal incision is needed to remove the specimen and perform an anastomosis. Five trocars (one 12 mm and four 5 mm) were used. The video describes the technique of performing laparoscopic subtotal colectomy, laparoscopic cholecystectomy, transrectal removal of the gallbladder and the entire colon, and intracorporeal stapled ileorectal anastomosis in a 27-year-old female with colonic inertia and biliary dyskinesia. There were no intraoperative complications. The operating time was 180 min. Blood loss was 10 cc. The patient was discharged home on postoperative day 4. Laparoscopic subtotal colectomy with transrectal removal of the colon is a safe and effective procedure that can be added to the armamentarium of surgeons performing laparoscopic colon surgery. This technique may provide both an attractive way to reduce abdominal wall morbidity and a bridge to NOTES colon surgery.

  11. Subtotal resection and omentoplasty of the epidermoid splenic cyst: a case report

    OpenAIRE

    Krasniqi, Avdyl S; Spahija, Gazmend S; Hashani, Shemsedin I; Osmani, Eshref A; Hoxha, Sejdullah A; Hamza, Astrit H; Gashi-Luci, Lumturije H

    2009-01-01

    Introduction Nonparasitic splenic cysts are uncommon clinical entity and because of it, there is no information regarding their optimal surgical treatment. Case presentation A 41-years-old female with incidentally diagnosed nonparasitic splenic cyst which initially was asymptomatic. After two years of follow up, the patient underwent surgery; subtotal cystectomy and omentoplasty as an additional procedure. Postoperative course was uneventful. Conclusion Short and mid term results showed that ...

  12. Subtotal parathyroidectomy for secondary renal hyperparathyroidism: a 20-year surgical outcome study.

    Science.gov (United States)

    Konturek, Aleksander; Barczyński, Marcin; Stopa, Małgorzata; Nowak, Wojciech

    2016-11-01

    The aim of this study was to evaluate the outcomes of surgery for patients with secondary renal hyperparathyroidism (rHPT). This is a retrospective cohort study. Our institutional database was searched for eligible patients treated in 1995-2014. The inclusion criterion was initial parathyroidectomy for rHPT. Clinical and follow-up data were analyzed to estimate the cure rate (primary outcome), and morbidity (secondary outcome). The study group comprised 297 patients (154 females, age 44.5 ± 13.7 years, follow-up 24.6 ± 10.5 months), including 268 (90.2 %) patients who had underwent subtotal parathyroidectomy, and 29 (9.8 %) who had had incomplete parathyroidectomy. Intraoperative iPTH assay was utilized in 207 (69.7 %) explorations. Persistent rHPT occurred in 12/268 (4.5 %) patients after subtotal parathyroidectomy and 5/29 (17.2 %) subjects after incomplete parathyroidectomy (p = 0.005). The patients operated on with intraoperative iPTH assay had a higher cure rate than non-monitored individuals, 201/207 (97.1 %) vs. 79/90 (87.8 %), respectively (p = 0.001). In-hospital mortality occurred in 1/297 (0.3 %) patient. The hungry bone syndrome occurred in 84/268 (31.3 %) patients after subtotal parathyroidectomy and 2/29 (6.9 %) subjects after incomplete parathyroidectomy (p = 0.006). Transient recurrent laryngeal nerve paresis occurred in 14/594 (2.4 %) and permanent in 5/594 (0.8 %) nerves at risk. Subtotal parathyroidectomy is a safe and efficacious treatment for patients with rHPT. Utilization of intraoperative iPTH assay can guide surgical exploration and improve the cure rate.

  13. International guidelines for contrast-enhanced ultrasonography

    DEFF Research Database (Denmark)

    Nolsøe, Christian Pállson; Lorentzen, Torben

    2016-01-01

    The intent of this review is to discuss and comment on common clinical scenarios in which contrast-enhanced ultrasonography (CEUS) may play a decisive role and to illustrate important points with typical cases. With the advent of CEUS, the scope of indications for ultrasonography has been dramati...

  14. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncică, Ana Maria; Săftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...... cancers and visualization of the portal venous system and esophageal varices. In addition, contrast agents can be used to differentiate pancreatic lesions. The use of color Doppler further increases the ability to diagnose and differentiate various pancreatic malignancies. The sensitivity of power Doppler...

  15. Subtotal Colectomy for Colon Cancer Reduces the Need for Subsequent Surgery in Lynch Syndrome.

    Science.gov (United States)

    Renkonen-Sinisalo, Laura; Seppälä, Toni T; Järvinen, Heikki J; Mecklin, Jukka-Pekka

    2017-08-01

    The risk of metachronous colorectal cancer is high after surgical resection for first colon cancer in Lynch syndrome. This study aimed to examine whether extended surgery decreases the risk of subsequent colorectal cancer and improves long-term survival. This was a retrospective study. Data were collected from a nationwide registry. Two hundred forty-two Lynch syndrome pathogenic variant carriers who underwent surgery for a first colon cancer from 1984 to 2009 were included. Patients underwent standard segmental colectomy (n = 144) or extended colectomy (n = 98) for colon cancer. Patients were followed a median of 14.6 up to 25 years. Risk of subsequent colorectal cancer in either group, overall and disease-specific survival, and operative mortality were the primary outcomes measured. Subtotal colectomy decreased the risk of subsequent colorectal cancer (HR, 0.20; 95% CI, 0.08-0.52; p = 0.001), compared with segmental resection. Subsequent colorectal cancer decreased in MLH1 carriers. The MSH2 carriers showed no statistical difference, possibly because of their small number. Disease-specific and overall survival within 25 years did not differ between the standard and extended surgeries (82.7% vs 87.2%, p = 0.76 and 47.2% vs 41.4%, p = 0.83). The cumulative risk of subsequent colorectal cancer was 20% in 10 years and 47% within 25 years after standard resection and 4% and 9% after extended surgery. The cumulative risk of metachronous colorectal cancer was 7% within 25 years after subtotal colectomy with ileosigmoidal anastomosis. One patient died of postoperative septicemia within 30 days after segmental colectomy. Data on surgical procedures were primarily collected retrospectively. Lynch syndrome pathogenic variant carriers may undergo subtotal colectomy to manage first colon cancer and avoid repetitive abdominal surgery and to reduce the remaining bowel to facilitate easier endoscopic surveillance. It provides no survival benefit, compared with segmental colon

  16. One hundred cases of laparoscopic subtotal hysterectomy using the PK and Lap Loop systems.

    Science.gov (United States)

    Erian, John; El-Toukhy, Tarek; Chandakas, Stefanos; Theodoridis, Theo; Hill, Nicholas

    2005-01-01

    To evaluate the safety and short-term outcomes of laparoscopic subtotal hysterectomy using the PK and Lap Loop systems. Prospective observational study (Canadian Task Force classification II-2). Princess Royal University and Chelsfield Park Hospitals, Kent, UK. One hundred women who underwent laparoscopic subtotal hysterectomy for menorrhagia from February 2003 through July 2004. The procedure was performed using the Plasma Kinetic (PK) system to seal the vascular pedicles and the Lap Loop system to separate the uterus at the level of the internal os. The uterus was removed from the abdominal cavity mainly by morcellation or posterior colpotomy. Of 100 patients, 59 were operated on as outpatients. Mean patient age was 44.6 years, median parity was 2, mean body mass index was 26.8, and mean duration of symptoms was 4 years. Clinically, the uterus was enlarged in 70 patients, and preoperative ultrasound scanning suggested the presence of uterine myomas in 42 patients. In addition to hysterectomy, 47 patients had concomitant pelvic surgery. The mean total operating time was 45.5 minutes, and mean estimated blood loss was 114 mL. The overall major complication rate was 2%; two patients required blood transfusion after surgery. There were no bowel or urinary tract injuries, unintended laparotomy, return to operating room, or anesthetic complications. At follow-up, all patients were satisfied with surgery. Laparoscopic subtotal hysterectomy using the PK and Lap Loop systems for treatment of therapy-resistant menorrhagia is safe, can be performed as an outpatient procedure, and is associated with reduced operating time and high patient satisfaction.

  17. Subtotal resection and omentoplasty of the epidermoid splenic cyst: a case report

    Science.gov (United States)

    Spahija, Gazmend S; Hashani, Shemsedin I; Osmani, Eshref A; Hoxha, Sejdullah A; Hamza, Astrit H; Gashi-Luci, Lumturije H

    2009-01-01

    Introduction Nonparasitic splenic cysts are uncommon clinical entity and because of it, there is no information regarding their optimal surgical treatment. Case presentation A 41-years-old female with incidentally diagnosed nonparasitic splenic cyst which initially was asymptomatic. After two years of follow up, the patient underwent surgery; subtotal cystectomy and omentoplasty as an additional procedure. Postoperative course was uneventful. Conclusion Short and mid term results showed that near total cystectomy with omentoplasty was a safe successful procedure for treatment of epidermoid splenic cyst. PMID:19829799

  18. The treatment of acute corneal hydrops by subtotal penetrating keratoplasty. Clinical case

    Directory of Open Access Journals (Sweden)

    I. A. Loskutov

    2014-07-01

    Full Text Available Clinical case of acute hydrops treatment using subtotal penetrating keratoplasty (PK is presented. The diagnosis of acute hydrops was based on clinical and functional evaluations including optical coherent tomography (OCT. A part of diseased cornea was removed and examined under a light microscope. These studies revealed morphological changes in almost all corneal layers. OCT and histology demonstrated that PK was indicated to this patient. Recent literature data on the epidemiology and pathogenesis of acute hydrops are presented. This rare disease results from tears in the Descemet’s membrane that allow aqueous humor to enter the stroma. Current treatment is aimed to suppress corneal inflammation, restore endothelium and Descemet’s membrane integrity and drain stromal cysts to optimize cornea healing. In this case, subtotal PK was performed due to the significant corneal thinning and a high risk of its melting. «Material for corneal graft» (iLab, Moscow, Russia was used as a donor material.

  19. Subtotal resection for management of large jugular paragangliomas with functional lower cranial nerves.

    Science.gov (United States)

    Wanna, George B; Sweeney, Alex D; Carlson, Matthew L; Latuska, Richard F; Rivas, Alejandro; Bennett, Marc L; Netterville, James L; Haynes, David S

    2014-12-01

    To evaluate tumor control following subtotal resection of advanced jugular paragangliomas in patients with functional lower cranial nerves and to investigate the utility of salvage radiotherapy for residual progressive disease. Case series with planned chart review. Tertiary academic referral center. Patients who presented with advanced jugular paragangliomas and functional lower cranial nerves were analyzed. Primary outcome measures included extent of resection, long-term tumor control, need for additional treatment, and postoperative lower cranial nerve function. Twelve patients (mean age, 46.2 years; 7 women, 58.3%) who met inclusion criteria were evaluated between 1999 and 2013. The mean postoperative residual tumor volume was 27.7% (range, 3.5%-75.0%) of the preoperative volume. When the residual tumor volume was less than 20% of the preoperative volume, no tumor growth occurred over an average of 44.6 months of follow-up (P cranial neuropathy as a result of surgery. Subtotal resection of jugular paragangliomas with preservation of the lower cranial nerves is a viable management strategy. If more than 80% of the preoperative tumor volume is resected, the residual tumor seems less likely to grow. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  20. Esplenectomia subtotal por via laparoscópica em cães

    Directory of Open Access Journals (Sweden)

    Andy Petroianu

    Full Text Available OBJETIVO: O objetivo deste trabalho foi determinar a exeqüibilidade, reprodutibilidade e segurança da esplenectomia subtotal por via laparoscópica e suas repercussões morfológicas, hematológicas, imunitárias e de depuração sangüínea, comparando esses dados com os obtidos na esplenectomia laparotómica. MÉTODO: Este estudo experimental foi conduzido de acordo com os princípios éticos de pesquisa experimental, propostos pelo Comitê de Ética em Experimentação Animal da UFMG. Quatorze cães adultos mestiços de ambos os sexos foram distribuídos em dois grupos (n = 7: Grupo 1 - Esplenectomia subtotal laparoscópica, preservando o polo superior suprido exclusivamente pelos vasos esplenogástricos; a secção esplênica e hemostasia foram realizadas utilizando um grampeador linear cortante laparoscópico com carga de 45 mm de extensão. Grupo 2 - Esplenectomia total, realizada por meio de laparotomia mediana. Depois de três meses, foram analisadas as alterações nos exames hematológico, imunitário e cintilográfico em todos os animais. Secções dos remanescentes esplênicos, fígado e linfonodos foram avaliadas histologicamente. RESULTADOS: Todos os procedimentos transcorreram sem complicações, não havendo morte operatória e com perda sangüínea mínima. Todos os animais sobreviveram à operação durante os três meses de acompanhamento. Após esse período, houve redução da contagem de plaquetas (p < 0,05 no Grupo 1. O restante dos exames hematológicos permaneceu normal. Os remanescentes esplênicos apresentaram arquitetura semelhante ao baço normal. Não houve alterações histológicas nos linfonodos e fragmentos hepáticos. CONCLUSÕES: É possível e segura a realização da esplenectomia subtotal por via laparoscópica no cão.

  1. Ultrasonography and surgery of canine biliary diseases.

    Science.gov (United States)

    Vörös, K; Németh, T; Vrabély, T; Manczur, F; Tóth, J; Magdus, M; Perge, E

    2001-01-01

    Findings of hepatic and gallbladder ultrasonography were analyzed in 12 dogs with gallbladder and/or extrahepatic biliary tract obstruction and compared with the results of exploratory laparotomy. Hepatic ultrasonography demonstrated normal liver in 2 dogs and hepatic abnormalities in 10 animals. The following ultrasonographic diagnoses were established compared to surgical findings: gallbladder obstruction caused by bile sludge (correct/incorrect: 1/2, surgical diagnosis: choleliths in one case), gallbladder obstruction caused by neoplasm (0/1, surgical diagnosis: mucocele), gallbladder and extrahepatic biliary tract obstruction due to choleliths (3/3), extrahepatic biliary tract obstruction caused by pancreatic mass (1/1) and small intestinal volvulus (1/1). Bile peritonitis caused by gallbladder rupture (4/4) was correctly diagnosed by ultrasound, aided with ultrasonographically-guided abdominocentesis and peritoneal fluid analysis. Rupture of the gallbladder should be suspected in the presence of a small, echogenic gallbladder or in the absence of the organ together with free abdominal fluid during ultrasonography. Laparotomy was correctly indicated by ultrasonography in all cases. However, the direct cause of obstruction could not be determined in 2 of the 12 dogs by ultrasonography alone.

  2. Role of Ultrasonography in Acute Abdomen

    International Nuclear Information System (INIS)

    An, Ji Hyun; Lee, Yeon Hee; Kim, Tae Hoon; Yu, Pil Mun; Choi, Young Hi; Kim, Sang Joon; Kim, Seung Cheul; Cho, Jeong Hee; Jung, Jae Un

    1996-01-01

    Authors analyzed the distribution of diseases and compared ultrasonographic conclusions with confirmed diagnoses of emergency abdominal ultrasonographies in acute abdominal conditions. We evaluated the role of emergency abdominal ultrasonography especially in the decision of emergency operation. In one hundred and forty five patients, emergent abdominal ultrasonography was performed within on admission. We compared the sonographic conclusion with postoperative pathology and analyzed the diagnoses of medically treated diseases. Twenty-eight patients under vent surgery and 117 patients were treated conservatively. Among the surgically treated patients, 19 patients (70.4%) were correctly diagnosed by preoperative ultrasonography.These included acute appendicitis (N = 8), acute cholecystitis (n = 7), ovarian cyst torsion (n = 2), and liver abscess (n = 1). Correct preoperative diagnosis was not made in 9 patients, including acute appendicitis (n = 4),peritonitis due to bowel perforation (n = 2), ectopic pregnancy (n = 1), colonic diverticulitis (n = 1 ) and pelvic inflammatory disease (n = 1 ). Clinical follow up was possible in 50 patients among the non-operative patient group, and the clinical diagnoses were chronic liver disease (n = 14), acute pyelonephritis (n = 10), and biliary stone (n = 10). Emergent ultrasonography plays an important role in acute abdominal conditions by supporting the differential diagnosis of medical and surgical disease

  3. Role of Ultrasonography in Acute Abdomen

    Energy Technology Data Exchange (ETDEWEB)

    An, Ji Hyun; Lee, Yeon Hee; Kim, Tae Hoon; Yu, Pil Mun; Choi, Young Hi; Kim, Sang Joon; Kim, Seung Cheul; Cho, Jeong Hee [Dankook University College of Medicine, Cheonan (Korea, Republic of); Jung, Jae Un [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1996-12-15

    Authors analyzed the distribution of diseases and compared ultrasonographic conclusions with confirmed diagnoses of emergency abdominal ultrasonographies in acute abdominal conditions. We evaluated the role of emergency abdominal ultrasonography especially in the decision of emergency operation. In one hundred and forty five patients, emergent abdominal ultrasonography was performed within on admission. We compared the sonographic conclusion with postoperative pathology and analyzed the diagnoses of medically treated diseases. Twenty-eight patients underwent surgery and 117 patients were treated conservatively. Among the surgically treated patients, 19 patients (70.4%) were correctly diagnosed by preoperative ultrasonography.These included acute appendicitis (N = 8), acute cholecystitis (n = 7), ovarian cyst torsion (n = 2), and liver abscess (n = 1). Correct preoperative diagnosis was not made in 9 patients, including acute appendicitis (n = 4), peritonitis due to bowel perforation (n = 2), ectopic pregnancy (n = 1), colonic diverticulitis (n = 1) and pelvic inflammatory disease (n = 1). Clinical follow up was possible in 50 patients among the non-operative patient group, and the clinical diagnoses were chronic liver disease (n = 14), acute pyelonephritis (n = 10), and biliary stone (n = 10). Emergent ultrasonography plays an important role in acute abdominal conditions by supporting the differential diagnosis of medical and surgical disease

  4. Prospective study of the changes in thyrotropin binding inhibitory immunoglobulins in Graves' disease treated by subtotal thyroidectomy or radioactive iodine

    International Nuclear Information System (INIS)

    Teng, C.S.; Yeung, R.T.T.; Khoo, R.K.K.; Alagaratnam, T.T.

    1980-01-01

    The effects of subtotal thyroidectomy and radioactive iodine on thyroid-stimulating immunoglobulins, as measured by a receptor assay, more appropriately termed TSH binding inhibitory immunoglobulins (TBII), were studied in 74 patients with Graves' disease. Fourty-four patients received radioactive iodine therapy, while 30 were subjected to subtotal thyroidectomy. After radioactive iodine, more patients were TBII-positive (90.5% vs 81.8%) than before treatment, and the mean TBII index decreased dramatically, the maximum decrease being 3 months. The mean TBI index subsequently returned gradually to the pretreatment level. Subtotal thyroidectomy had a different effect on TBII activity. TBII indices were positive in 89.3% of these patients before any treatment but were positive in only 40% (12 patients) after antithyroid drugs had been given before surgery. After surgery, TBII indices remained positive in 7 patients, while the remaining 5 patients became TBII negative. Seventeen patients (56.7%) were TBII negative before operation and remained so after surgery. One patient who was TBII negative before operation became TBII positive 2 months after operation. Interestingly, postoperative relapse of hyperthyroidism occurred in 3 patients who were TIBII positive, while hypothyroidism occurred in patients who were TBII negative. Thus, the TBII activity after subtotal thyroidectomy might be an important factor in determining the outcome of surgery

  5. Limitations of intraoperative adrenal remnant volume measurement in patients undergoing subtotal adrenalectomy.

    Science.gov (United States)

    Brauckhoff, Michael; Stock, Karsten; Stock, Susanne; Lorenz, Kerstin; Sekulla, Carsten; Brauckhoff, Katrin; Thanh, Phuong Nguyen; Gimm, Oliver; Spielmann, Rolf Peter; Dralle, Henning

    2008-05-01

    Recent studies have shown that a minimum of approximately one-third of one normal adrenal gland is required for sufficient adrenocortical stress capacity. Correlation between intraoperative measurement, determination of remnant size by computed tomography (CT), and adrenocortical stress capacity has not been examined so far. Twenty-two patients with familial pheochromocytoma (n=13), sporadic pheochromocytoma (n=3), and adrenocortical tumors (n=6) who underwent unilateral or bilateral subtotal adrenalectomy (STAE, 28 adrenal remnants) were prospectively studied. Patients were examined in a multi-slice CT to determine residual adrenal tissue and by ACTH test 4 days and 3 months postoperatively. There was a slight significant correlation between intraoperative and CT calculated volumes (r=0.77; pSTAE has limitations. CT gives larger volumes compared with intraoperative determination. For calculation of a volume-function correlation of residual adrenal tissue, in clinical practice, the determination of relative adrenal residual volume is acceptable.

  6. Iatrogenic Subtotal Stenosis of the Right Subclavian Artery Treated With Percutaneous Transluminal Angioplasty

    International Nuclear Information System (INIS)

    Smeenk, Robert M.; Kock, Mark C. J. M.; Elgersma, Otto E. H.; Schnater, Marco J.

    2011-01-01

    This report describes a rare vascular complication of surgical placement of a marking clip and a possible approach to problem solving. A 55-year-old patient presented with loss of sensation in the fingers and loss of peripheral pulsations in the right arm 4 days after right upper lobectomy for a pT2N1 moderately differentiated adenocarcinoma of the lung. Duplex examination and computed tomography were performed the same day and showed a subtotal stenosis of the right subclavian artery, which was caused by the surgical placement of a metal clip to mark the surgical boundary. Selective angiography was subsequently performed. Percutaneous transluminal angioplasty (PTA) successfully dilated the stenosis and pushed the clip off. Flow in the right subclavian artery (RSA) was completely restored as were neurology and peripheral pulses. In conclusion, arterial stenosis by a surgical (marking) clip may be feasibly treated with PTA.

  7. Acute iatrogenic polycythemia induced by massive red blood cell transfusion during subtotal abdominal colectomy

    Directory of Open Access Journals (Sweden)

    David Chiapaikeo

    2015-03-01

    Full Text Available A 46 year old man was transfused ten units of packed red blood cells during subtotal colectomy after intraoperative point-of-care testing values demonstrated hemoglobin values less than seven grams per deciliter (g/dL. A post-operative hemoglobin analyzed in a standard hematologic laboratory revealed a hemoglobin value of 27.8 g/dL. He underwent emergent red blood cell depletion therapy which decreased his hemoglobin to 7.5 g/dL. The physiologic consequences of iatrogenic polycythemia caused by massive transfusion during major abdominal surgery must take into account the fluid shifts that interplay between the osmotic load, viscosity of blood, and postoperative third spacing of fluid. Treatment of acute iatrogenic polycythemia can be effectively accomplished by red blood cell depletion therapy. However, fluid shifts caused by massive transfusion followed by rapid red cell depletion produce a unique physiologic state that is without a well-described algorithm for management.

  8. Subtotal parathyroidectomy for primary hyperparathyroidism. Long-term results in 292 patients

    International Nuclear Information System (INIS)

    Paloyan, E.; Lawrence, A.M.; Oslapas, R.; Shah, K.H.; Ernst, K.; Hofmann, C.

    1983-01-01

    Subtotal parathyroidectomy was performed in a consecutive series of 292 patients with primary hyperparathyroidism. We evaluated the long-term postoperative results during a period of 16 years. Patients ranged in age from 14 to 83 years and included 176 women and 116 men. Of these, 16% had a history of exposure to radiation in childhood or adolescence, while thyroid disease requiring some form of thyroidectomy coexisted in 91 (31%) of the patients. Histologic information on three or more parathyroid glands was obtained in 73% of the cases. We considered 285 patients (97.6%) cured after their first operation. The remaining seven patients (2.4%) had persistent hyperparathyroidism. However, five were cured after a sternum-splitting mediastinal exploration and one after a second neck exploration. The seventh remains hypercalcemic despite a subsequent mediastinal exploration. Temporary postoperative hypoparathyroidism occurred in 10% of our cases and permanent hypoparathyroidism in 1%. There have been no instances of recurrent hyperparathyroidism

  9. Ultrasonography of the scrotum in adults

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Anna L.; Scotegagna, Eduardo; Nowitaki, Kristina M.; Kim, Young M. [Dept. of UMass Memorial Medical Center, University of Massachusetts Medical Center, Worcester (United States)

    2016-07-15

    Ultrasonography is the ideal noninvasive imaging modality for evaluation of scrotal abnormalities. It is capable of differentiating the most important etiologies of acute scrotal pain and swelling, including epididymitis and testicular torsion, and is the imaging modality of choice in acute scrotal trauma. In patients presenting with palpable abnormality or scrotal swelling, ultrasonography can detect, locate, and characterize both intratesticular and extratesticular masses and other abnormalities. A 12-17 MHz high frequency linear array transducer provides excellent anatomic detail of the testicles and surrounding structures. In addition, vascular perfusion can be easily assessed using color and spectral Doppler analysis. In most cases of scrotal disease, the combination of clinical history, physical examination, and information obtained with ultrasonography is sufficient for diagnostic decision-making. This review covers the normal scrotal anatomy as well as various testicular and scrotal lesions.

  10. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    International Nuclear Information System (INIS)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung

    1996-01-01

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  11. Resultados a largo plazo de la parotidectomía subtotal para tumores mixtos

    Directory of Open Access Journals (Sweden)

    Manuel Estrada Sarmiento

    2001-12-01

    Full Text Available Resumen Se realiza una investigación retrospectiva de las historias clínicas de 31 pacientes con tumor mixto de la glándula parótida consecutivamente tratados con una parotidectomía subtotal en nuestro Departamento, desde 1979 hasta 1983, ambos inclusives. De los 31 pacientes 12 eran masculinos (38,7 % y 19 femeninos (61,3 %. La parótida derecha fue la más afectada; la incisión quirúrgica de Blair se empleó en 19 pacientes. La paresia del nervio facial se presentó en el 32,2 % de la serie. La apreciación de la supervivencia y el control local a los 10 y 15 años fueron de 90,3 y 0 % y 80,6 % y 0, respectivamente.A retrospective investigation of the medical histories of 31 patients with mixed tumor of the parotid gland that were consecutively treated with subtotal parotidectomy in our Department from 1979 to 1983, including both, was made. Of the 31 patients 12 were males (38.7 % and 19 females (61.3 %. The right parotid was the most affected. Blair’s surgical incision was used in 19 patients. 32.2 % of the series had paresis of the facial nerve.The estimation of survival and the local control at 10 and 15 years old were 90.3 and 0 %, and 80.6 and 0 %, respectively.

  12. Iodine-induced thyrotoxicosis--a case for subtotal thyroidectomy in severely ill patients.

    Science.gov (United States)

    Köbberling, J; Hintze, G; Becker, H D

    1985-01-02

    Iodine-induced thyrotoxicosis (IIT), due to iodine application in high amounts in patients with circumscript or disseminated thyroid autonomy, is complicated by a prolonged course, mainly due on the body's resistance to conservative therapy with thiourea derivates. Therefore, we decided to perform subtotal thyroidectomy in 16 thyrotoxic patients. This is in contrast to the common opinion that surgery should only be performed after normalization of thyroid hormones. In all 16 patients with severe IIT, including three patients with thyroid storm, hormone levels decreased within a few days after surgery to normal or subnormal values and the clinical picture of thyrotoxicosis disappeared. In the case of thyroid storm the signs of disorientation normalized within 1-3 days. One patient died 5 weeks after surgery due to severe concomitant diseases. One patient exhibited transitory respiration distress and another had postoperative hypocalcaemia. In nine patients L-thyroxine replacement became necessary because of subclinical or clinical hypothyroidism. Only by this procedure will the high intrathyroidal storage of iodine and performed hormone be extracted. Surgery as a treatment for thyrotoxicosis should be reserved for patients with severe IIT, where conservative treatment has been shown to be ineffective. Furthermore, in rare selected cases, when a rapid normalization is required, surgery without preoperative treatment seems to be justified. The effect of surgery was impressive in all our cases and there were only minor perioperative complications. Thus, it could be shown that subtotal thyroidectomy may be a rational and effective treatment in severe IIT which should be carefully considered and weighed against other types of therapy.

  13. Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization.

    Science.gov (United States)

    Liu, Jian; Jing, Linkai; Wang, Chao; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-11-01

    Endovascular treatment of paraclinoid aneurysms is preferred in clinical practice. Flow alterations caused by stents and coils may affect treatment outcome. To assess hemodynamic changes following stent-assisted coil embolization (SACE) in subtotally embolized paraclinoid aneurysms with residual necks that were predisposed to recanalization. We studied 27 paraclinoid aneurysms (seven recanalized and 20 stable) treated with coils and Enterprise stents. Computational fluid dynamic simulations were performed on patient-specific aneurysm geometries using virtual stenting and porous media technology. After stent placement in 27 cases, aneurysm flow velocity decreased significantly, the reduction gradually increasing from the neck plane (11.9%), to the residual neck (12.3%), to the aneurysm dome (16.3%). Subsequent coil embolization was performed after stent placement and the hemodynamic factors decreased further and significantly at all aneurysm regions except the neck plane. In a comparison of recanalized and stable cases, univariate analysis showed no significant differences in any parameter before treatment. After stent-assisted coiling, only the reduction in area-averaged velocity at the neck plane differed significantly between recanalized (8.1%) and stable cases (20.5%) (p=0.016). Aneurysm flow velocity can be significantly decreased by stent placement and coil embolization. However, hemodynamics at the aneurysm neck plane is less sensitive to coils. Significant reduction in flow velocity at the neck plane may be an important factor in preventing recanalization of paraclinoid aneurysms after subtotal SACE. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  14. Scintigraphy and ultrasonography of various thyroid diseases

    International Nuclear Information System (INIS)

    Ban, Yoshio; Nagakura, Hozumi; Kawauchi, Akihiro; Fukunari, Nobuhiro; Itoh, Kunihiko; Higashi, Tomomitsu.

    1987-01-01

    We reported the usefulness of scintigraphy and ultrasonography of various thyroid diseases. The scintigraphy were useful information in the determination of functioning adenoma, location of ectopic thyroid glands and appearance of lang and bone metastasis of thyroid carcinoma. As ultrasonography were able to be observation of internal structure of thyroid gland, that maight be used to determined associated nodular lesions in diffuse goiter and differentiation between benign and malignant tumor in nodular goiter. In observation of calcifications of goiter, soft X rays apparatus were usefull tool. US, as initial diagnostic test before scintiscanning, provided useful information and minimized radiation exposure. (author)

  15. Transabdominal Ultrasonography of the Small Bowel

    Directory of Open Access Journals (Sweden)

    Rudolf Kralik

    2013-01-01

    Full Text Available In the era of double balloon enteroscopy, capsule endoscopy, CT, and MRI enterography is transabdominal ultrasonography (TUS underestimated method for evaluation of small bowel pathology. As often initial imagine method in abdominal complaints, nowadays has TUS much better diagnostic potential than two decades ago. High-resolution ultrasound probes with harmonic imaging significantly improve resolution of bowel wall in real time, with possibility to asses bowel peristalsis. Color flow doppler enables evaluation of intramural bowel vascularisation, pulse wave doppler helps to quantificate flow in coeliac and superior mesenteric arteries. Small intestine contrast ultrasonography with oral contrast fluid, as well as contrast enhanced ultrasonography with intravenous microbubble contrast also improves small bowel imaging. We present a review of small intestine pathology that should be detected during ultrasound examinations, discuss technical requirements, advantages and limitations of TUS, typical ultrasound signs of Crohn's disease, ileus, celiac disease, intussusception, infectious enteritis, tumours, ischemic and haemorrhagic conditions of small bowel. In the hands of experienced investigator, despite some significant limitations(obesity, meteorism, is transabdominal ultrasonography reliable, noninvasive and inexpensive alternative method to computerised tomography (CT and magnetic resonance imaging (MRI in small bowel examination.

  16. Emergency surgeon-performed hepatobiliary ultrasonography.

    LENUS (Irish Health Repository)

    Kell, M R

    2012-02-03

    BACKGROUND: Acute hepatobiliary pathology is a common general surgical emergency referral. Diagnosis requires imaging of the biliary tree by ultrasonography. The accuracy and impact of surgeon-performed ultrasonography (SUS) on the diagnosis of emergent hepatobiliary pathology was examined. METHODS: A prospective study, over a 6-month period, enrolled all patients with symptoms or signs of acute hepatobiliary pathology. Patients provided informed consent and underwent both SUS and standard radiology-performed ultrasonography (RUS). SUS was performed using a 2-5-MHz broadband portable ultrasound probe by two surgeons trained in ultrasonography, and RUS using a 2-5-MHz fixed unit. SUS results were correlated with those of RUS and pathological diagnoses. RESULTS: Fifty-three consecutive patients underwent 106 ultrasonographic investigations. SUS agreed with RUS in 50 (94.3 per cent) of 53 patients. SUS accurately detected cholelithiasis in all but two cases and no patient was inaccurately diagnosed as having cholelithiasis at SUS (95.2 per cent sensitivity and 100 per cent specificity). As an overall complementary diagnostic tool SUS provided the correct diagnosis in 96.2 per cent of patients. Time to scan was significantly shorter following SUS (3.1 versus 12.0 h, P < 0.05). CONCLUSION: SUS provides a rapid and accurate diagnosis of emergency hepatobiliary pathology and may contribute to the emergency management of hepatobiliary disease.

  17. Quantitative muscle ultrasonography in amyotrophic lateral sclerosis.

    NARCIS (Netherlands)

    Arts, I.M.P.; Rooij, F.G. van; Overeem, S.; Pillen, S.; Janssen, H.M.; Schelhaas, H.J.; Zwarts, M.J.

    2008-01-01

    In this study, we examined whether quantitative muscle ultrasonography can detect structural muscle changes in early-stage amyotrophic lateral sclerosis (ALS). Bilateral transverse scans were made of five muscles or muscle groups (sternocleidomastoid, biceps brachii/brachialis, forearm flexor group,

  18. Esplenectomia subtotal para tratamento do hipodesenvolvimento somático e sexual secundário a esplenomegalia

    Directory of Open Access Journals (Sweden)

    Andy Petroianu

    Full Text Available OBJETIVO: "Nanismo esplênico" é condição clínica decorrente de processo imunitário relacionado ao baço e tem como tratamento preconizado a esplenectomia total. Seguindo uma linha de pesquisa voltada ao estudo da esplenectomia subtotal em diferentes afecções, o objetivo do presente trabalho foi avaliar o crescimento somático de pacientes portadores deste hipodesenvolvimento esplenomegálico, submetidos à esplenectomia subtotal com preservação do pólo superior esplênico irrigado apenas pelos vasos esplenogástricos. MÉTODO: Quatro pacientes masculinos (14, 14, 16 e 17 anos com esplenomegalia (três de etiologia esquistossomática e um com cirrose auto-imune e retardo do desenvolvimento somático e sexual foram submetidos à esplenectomia subtotal. As indicações para cirurgia foram sangramento de varizes do esôfago e pancitopenia. RESULTADOS: Em todos os casos houve retomada do crescimento e após um ano eles já se encontravam dentro da faixa de desenvolvimento somático e sexual compatível com a idade. CONCLUSÃO: O hipodesenvolvimento esplenomegálico não é decorrente da presença do baço, mas de seu crescimento; a esplenectomia subtotal é um procedimento adequado para tratar o retardo de desenvolvimento somático e sexual por esplenomegalia.

  19. Laparoscopic and open subtotal colectomies have similar short-term results.

    Science.gov (United States)

    Hoogenboom, Froukje J; Bosker, Robbert J I; Groen, Henk; Meijerink, Wilhelmus J H J; Lamme, Bas; Pierie, Jean Pierre E N

    2013-01-01

    Laparoscopic subtotal colectomy (STC) is a complex procedure. It is possible that short-term benefits for segmental resections cannot be attributed to this complex procedure. This study aims to assess differences in short-term results for laparoscopic versus open STC during a 15-year single-institute experience. We reviewed consecutive patients undergoing laparoscopic or open elective or subacute STC from January 1997 to December 2012. Fifty-six laparoscopic and 50 open STCs were performed. The operation time was significantly longer in the laparoscopic group, median 266 min (range 121-420 min), compared to 153 min (range 90-408 min) in the open group (p < 0.001). Median hospital stay showed no statistical difference, 14 days (range 1-129 days) in the laparoscopic and 13 days (range 1-85 days) in the open group. Between-group postoperative complications were not statistically different. Laparoscopic STC has short-term results similar to the open procedure, except for a longer operation time. The laparoscopic approach for STC is therefore only advisable in selected patients combined with extensive preoperative counseling. Copyright © 2013 S. Karger AG, Basel.

  20. Laparoscopic subtotal gastrectomy for advanced gastric cancer: technical aspects and surgical, nutritional and oncological outcomes.

    Science.gov (United States)

    Nakauchi, Masaya; Suda, Koichi; Nakamura, Kenichi; Shibasaki, Susumu; Kikuchi, Kenji; Nakamura, Tetsuya; Kadoya, Shinichi; Ishida, Yoshinori; Inaba, Kazuki; Taniguchi, Keizo; Uyama, Ichiro

    2017-11-01

    Higher morbidity in total gastrectomy than in distal gastrectomy has been reported, but laparoscopic subtotal gastrectomy (LsTG) has been reported to be safe and feasible in early gastric cancer (GC). We determined the surgical, nutritional and oncological outcomes of LsTG for advanced gastric cancer (AGC). Of the 816 consecutive patients with GC who underwent radical gastrectomy at our institution between 2008 and 2012, 253 who underwent curative laparoscopic gastrectomy (LG) for AGC were enrolled. LsTG was indicated for patients with upper stomach third tumors, who hoped to avoid total gastrectomy, nutritional status were primarily assessed. Of 253 patients, the morbidity (Clavien-Dindo classification grade ≥ III) was 17.0% (43 patients). The 3-year overall survival and 3-year recurrence-free survival rates were 80.2 and 73.5%, respectively. LcDG, LsTG and LTG were performed in 121, 27 and 105 patients, individually. Morbidity was strongly associated with LTG (P = 0.001). Postoperative loss of body weight was significantly greater after LTG in comparison with LcDG or LsTG (P nutritional point of view.

  1. Comparative evaluation of two reconstructive methods following laparoscopic assisted subtotal gastrectomy in dogs

    Directory of Open Access Journals (Sweden)

    Bakhtiari Jalal

    2012-12-01

    Full Text Available Abstract Background Laparoscopic gastrectomy is a new and technically challenging surgical procedure with potential benefit. The objective of this study was to investigate clinical and para-clinical consequences following Roux-en-Y and Jejunal Loop interposition reconstructive techniques for subtotal gastrectomy using laparoscopic assisted surgery. Results Following resection of the stomach attachments through a laparoscopic approach, stomach was removed and reconstruction was performed with either standard Roux-en-Y (n = 5 or Jejunal Loop interposition (n = 5 methods. Weight changes were monitored on a daily basis and blood samples were collected on Days 0, 7 and 21 post surgery. A fecal sample was collected on Day 28 after surgery to evaluate fat content. One month post surgery, positive contrast radiography was conducted at 5, 10, 20, 40, 60 and 90 minutes after oral administration of barium sulfate, to evaluate the postoperative complications. There was a gradual decline in body weight in both experimental groups after surgery (P  0.05. Fecal fat content increased in the Roux-en-Y compared to the Jejunal loop interposition technique (P  0.05. Conclusion Roux-en-Y and Jejunal loop interposition techniques might be considered as suitable approaches for reconstructing gastro-intestinal tract following gastrectomy in dogs. The results of this study warrant further investigation with a larger number of animals.

  2. Aspergillus Tracheobronchitis Causing Subtotal Tracheal Stenosis in a Liver Transplant Recipient

    Directory of Open Access Journals (Sweden)

    Sonia Radunz

    2013-01-01

    Full Text Available Invasive aspergillosis is recognized as one of the most significant opportunistic infections after liver transplantation. Diagnosis of invasive aspergillosis in transplant recipients has been proven to be challenging, and optimal approach to the treatment of invasive aspergillosis is still controversial. We here present an unusual case of Aspergillus tracheobronchitis in the setting of liver transplantation. A 47-year-old female patient with persistent dry cough after liver transplantation developed respiratory insufficiency and was readmitted to the intensive care unit 55 days after liver transplantation. A CT scan revealed subtotal tracheal stenosis; bronchoscopy was performed, and extended white mucus coverings causative of the tracheal stenosis were removed. Microbiological assessment isolated Aspergillus fumigatus. The diagnosis was obstructive Aspergillus tracheobronchitis. The patient was started on a treatment of voriconazole 200 mg orally twice daily, adjusted to a trough level of 1–4 mg/L. For further airway management, a tracheal stent had to be implanted. The patient is alive and well 28 months after liver transplantation. Invasive aspergillosis should be considered a possible etiology in liver transplant patients presenting with unspecific symptoms such as persistent dry cough. Optimal strategies for improved and early diagnosis as well as prophylaxis need to be defined.

  3. [Is subtotal bilateral thyroidectomy still indicated in patients with Grave's disease?].

    Science.gov (United States)

    Bilosi, M; Binquet, C; Goudet, P; Lalanne-Mistrih, M L; Brun, J M; Cougard, P

    2002-02-01

    To evaluate the morbidity and the functional results of subtotal bilateral thyroidectomy in patients (TST) with Graves' disease. A retrospective study was performed in 128 patients. They were 23 males and 105 females with a median age of 34 years (range: 14-68). Weight of remnant tissue was between 4 and 5 g. Thyroid functional status was evaluated, at 3 months and after a follow-up period ranged from 1 to 5 years, by measurement of serum concentration of free T4 and/or free T3 and TSH. They were no post-operative death. Surgical complications were 2 vocal cord palsies and 17 hypocalcemia (inf. to 2 mmol/L). After a median follow-up of 2 years, they were no longer any cases of vocal cord dysfunction and no case of permanent hypoparathyroidism. Functional results were established in 118 patients: 46 patients had clinical hypothyroidism (39%), 64 patients had latent hypothyroidism or euthyroidism (54.2%), and 8 had recurrent hyperthyroidism (6.8%). These results suggest that TST with a remnant mass inferior to 5 g provides a low level of recurrent hyperthyroidism and allows to give no drug therapy to half patients. In our opinion, TST is still indicated in Graves' disease.

  4. Combined acupuncture and general anesthesia on immune and cognitive function in elderly patients following subtotal gastrectomy for gastric cancer.

    Science.gov (United States)

    Wang, Ningke; Ou, Yangwen; Qing, Wenxiang

    2018-01-01

    This study investigated the effects of acupuncture combined with general anesthesia on postoperative immune and cognitive functions in elderly patients undergoing subtotal gastrectomy. We recruited 96 elderly patients who received anesthesia for subtotal gastrectomy and randomly divided them into control (n=48) and experimental (n=48) groups. The control group received general anesthesia and the experimental group received combined acupuncture and general anesthesia. We measured hemodynamic immediately before and after anesthesia induction, and immune observations before and after surgery. We found no significant differences in mean heart rate (HR), mean oxygen saturation (SpO2), and partial pressure of end-tidal carbon dioxide (PETCO2) in the perioperative period between the two groups. Mean arterial pressure (MAP) was lower in the experimental group than that in the control group (P0.05), but the incidence of delayed recovery and postoperative agitation were significantly lower in the experimental group compared with those in the control group (P<0.05). One day after surgery, the experimental group showed better protection of cognitive function than the control group (P<0.05). Overall, combined acupuncture and general anesthesia in elderly gastric cancer patients receiving subtotal gastrectomy showed more stable hemodynamics and fewer stress responses during surgery. Thus, combined acupuncture and general anesthesia can shorten the recovery time from anesthesia, have less negative effects on immune function and decrease the incidence of postoperative cognitive impairment.

  5. Ultrasonography in Early Diagnosis of Heterotopic Ossification

    Directory of Open Access Journals (Sweden)

    Shan-Hui Lin

    2014-12-01

    Full Text Available We report here the case of a 32-year-old man with a history of traumatic brain injury who presented with swelling of his right thigh. Soft tissue ultrasonography performed 3 days after the onset of symptoms showed a heterogeneous hyperechoic lesion with the formation of cysts and hypervascularity in the right iliopsoas abutting the surface of the femoral bone. This became a diffuse echogenic plaque with a posterior acoustic shadowing 12 days later. A diagnosis of heterotopic ossification was made on the basis of the presence of typical ultrasonographic findings and was confirmed by pathology. We emphasize that an early diagnosis of heterotopic ossification can be made with ultrasonography and can lead to early treatment.

  6. Vascular access: the impact of ultrasonography

    Science.gov (United States)

    de Almeida, Carlos Eduardo Saldanha

    2016-01-01

    ABSTRACT Vascular punctures are often necessary in critically ill patients. They are secure, but not free of complications. Ultrasonography enhances safety of the procedure by decreasing puncture attempts, complications and costs. This study reviews important publications and the puncture technique using ultrasound, bringing part of the experience of the intensive care unit of the Hospital Israelita Albert Einstein, São Paulo (SP), Brazil, and discussing issues that should be considered in future studies. PMID:28076607

  7. Differential diagnosis of calf pain by ultrasonography

    Directory of Open Access Journals (Sweden)

    Luciano Augusto Botter

    2008-03-01

    Full Text Available This paper aims to evaluate the recent and numerous applications of ultrasonography in the differential diagnosis of conditions that affect the popliteal fossa and lower limbs, resulting in calf pain. Popliteal cysts and their ruptures, aneurysms, hematomas, cellulitis, abscesses, soft tissue tumors and other fluid collections are easily identified by this technique. Moreover, post-trauma and inflammatory conditions affecting muscles and tendons, muscle necrosis, deep venous thrombosis and superficial thrombophlebitis are very well demonstrated by the ultrasonographic screening.

  8. Differentiation of chronic total occlusion and subtotal occlusion of the femoropopliteal artery-role of retrograde flow sign and collateral circulation on CT angiography images.

    Science.gov (United States)

    Zhang, Shujun; Su, Yanfei; Chen, Haisong

    2017-08-01

    To study the value of a retrograde flow sign and the collateral circulation on CT angiography (CTA) for the differential diagnosis of chronic total occlusion from subtotal occlusion of the femoropopliteal artery (FPA). 50 patients with obstruction of the FPA underwent CTA and digital subtraction angiography examinations of the lower limbs. The frequency of a retrograde flow sign and collateral circulation on CTA in chronic total and subtotal occlusion was noted and analyzed, with the results of digital subtraction angiography as a standard to judge total or subtotal occlusion. The decreasing CT value from the distal to proximal direction on CTA suggests the existence of retrograde flow. There were significant differences in the occurrence rates of a retrograde flow sign on CTA in the chronic total and subtotal obstruction groups (X 2 = 13.1, p collateral circulation sign (X 2 = 13.5, p collateral circulation sign to diagnose chronic total obstruction of the FPA had a sensitivity of 92.3% and specificity of 89.8%. The retrograde flow sign combined with a collateral circulation sign is of great clinical value for differentiation of chronic total stenosis from severe stenosis (subtotal occlusion) of the FPA. Advances in knowledge: A retrograde flow sign combined with a collateral circulation sign is of great clinical value to differentiate between chronic total stenosis and severe stenosis (subtotal occlusion) of the FPA.

  9. Real time ultrasonography in obstructive jaundice

    International Nuclear Information System (INIS)

    Cho, Kyung Sik; Kim, Ho Kyun; Sung, Nak Kwan; Kim, Soon Yong

    1982-01-01

    Ultrasonography is a predominantly accurate, relatively simple unique diagnostic method of obstructive jaundice. The ultrasonographic findings of obstructive jaundice are dilated intra- and extrahepatic duct with intraluminal hyper reflective echo or mass in and/ or around the bile duct. The superiority of high resolution real time ultrasonography for the diagnosis of obstructive jaundice is bases on the easy detectability of extra- and intrahepatic bile ducts by its multiple sectional images in a short time, the flexibility of probe and small crystal size. Author evaluated real time sonographic findings 46 obstructive jaundice patients confirmed by surgery or radiographical examinations. The results were: 1. Diameter of extrahepatic duct in obstructive jaundice were varied from normal to 4.0 Cm, mostly 8 to 10 mm in diameter (26%). Degree of dilatation of biliary duct appeared more prominent in cancer patients than other causes of obstruction. 2. The site of obstruction was detected in 85% (39/46) and its common site was common bile duct in 63% (29/46). 3. The diagnostic accuracy of choledocholithiasis and cancer was 82% (22/27) and 44% (4/9), respectively. Diagnostic accuracy of the real time ultrasonography in obstructive jaundice was over all 75% (34/46)

  10. Total versus subtotal Laparoscopic Hysterectomy: A comparative study in Arash Hospital

    Directory of Open Access Journals (Sweden)

    Samiei H

    2009-09-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 st1":*{behavior:url(#ieooui } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Over the past 50 years, subtotal or supracervical hysterectomy has come to be viewed as a suboptimal procedure reserved for those rare instances in which when concern over blood loss or anatomic distortion dictates limiting the extent of dissection, the aim of this study was to compare total and subtotal laparoscopic hysterectomy. "n"nMethods: The patients who were candidates for hysterectomy with benign disease, with no contraindication for laparoscopic surgery entered the study in Arash Hospital, from March 2007 to April 2009. By simple randomization 45 patients (25 for TLH and 20 for SLH were selected. Demographic Details and intra and post operative complications, were recorded by the staff and were compared between two groups."n"nResults: The average time for TLH operations look significantly longer than SLH operation (148.6±29.7 minutes; 128.5±25.64 minutes, p=0.03. Although, the hemoglobin (gr/dl drop in TLH was significantly higher than SLH (1.54 Versus 0.9, p<0.05 Blood transfusion were common in SLH (1 case Versus 3 Cases. The total length of hospital stay, was significantly shorter after SLH than TLH (3.6±1.47 day and 2.85±0.59, p=0.04. The drug requirements to

  11. Lumbar subtotal corpectomy non-fusion model produced using a novel prosthesis.

    Science.gov (United States)

    Liu, Jiantao; Zhang, Feng; Gao, Zhengchao; Li, Yuhuan; Niu, Binbin; He, Xijing

    2017-11-01

    In this study, we aimed to design a movable artificial lumbar complex (MALC) prosthesis for non-fusion reconstruction after lumbar subtotal corpectomy and to establish an in vitro anterolateral lumbar corpectomy non-fusion model for evaluating the biomechanical stability, preservation of segment movements and influence on adjacent inter-vertebral movements of this prosthesis. Imaging was performed on a total of 26 fresh goat lumbar spine specimens to determine which of the specimens did not meet the requirements (free of deformity and fractures); the residual specimens were randomly divided into an intact group, a fusion group and a non-fusion group. Bone mineral density (BMD) was tested and compared among the three groups. Biomechanical testing was conducted to obtain the range of motion (ROM) in flexion-extension, lateral bending at L2-3, L3-4 and L4-5 and axial rotation at L2-5 in the three groups. Two specimens were excluded due to vertebral fractures. BMD showed no statistical significance among three groups (P > 0.05). The stability of the prosthesis did not differ significantly during flexion, extension, and lateral bending at L2-3, L3-4, and L4-5 and axial torsion at L2-5 between the intact group and the non-fusion group (P > 0.05). Segment movements of the specimens in the non-fusion group revealed significantly decreased L2-3 ROM and significantly increased L3-4 and L4-5 ROM in flexion and lateral bending compared with the fusion group (P inter-vertebral spaces. However, additional studies, including in vivo animal experiments as well as biocompatibility and biomechanical tests of human body specimens are needed.

  12. Characterization of a Murine Model of Bioequivalent Bladder Wound Healing and Repair Following Subtotal Cystectomy

    Directory of Open Access Journals (Sweden)

    Mona Zarifpour

    2017-05-01

    Full Text Available Previous work demonstrated restoration of a bioequivalent bladder within 8 weeks of removing the majority of the bladder (subtotal cystectomy or STC in rats. The goal of the present study was to extend our investigations of bladder repair to the murine model, to harness the power of mouse genetics to delineate the cellular and molecular mechanisms responsible for the observed robust bladder regrowth. Female C57 black mice underwent STC, and at 4, 8, and 12 weeks post-STC, bladder repair and function were assessed via cystometry, ex vivo pharmacologic organ bath studies, and T2-weighted magnetic resonance imaging (MRI. Histology was also performed to measure bladder wall thickness. We observed a time-dependent increase in bladder capacity (BC following STC, such that 8 and 12 weeks post-STC, BC and micturition volumes were indistinguishable from those of age-matched non-STC controls and significantly higher than observed at 4 weeks. MRI studies confirmed that bladder volume was indistinguishable within 3 months (11 weeks post-STC. Additionally, bladders emptied completely at all time points studied (i.e., no increases in residual volume, consistent with functional bladder repair. At 8 and 12 weeks post-STC, there were no significant differences in bladder wall thickness or in the different components (urothelium, lamina propria, or smooth muscle layers of the bladder wall compared with age-matched control animals. The maximal contractile response to pharmacological activation and electrical field stimulation increased over time in isolated tissue strips from repaired bladders but remained lower at all time points compared with controls. We have established and validated a murine model for the study of de novo organ repair that will allow for further mechanistic studies of this phenomenon after, for example, genetic manipulation.

  13. Acceptable short-term outcome of laparoscopic subtotal colectomy for inflammatory bowel disease.

    Science.gov (United States)

    Frid, Natalie Lassen; Bulut, Orhan; Pachler, Jørn

    2013-06-01

    Laparoscopic colectomy for both benign and malignant disease, including inflammatory bowel disease (IBD), has recently been shown to have many advantages compared with open surgery. This study aimed to compare the effect of laparoscopic versus open subtotal colectomy (STC) for IBD on overall morbidity. A total of 99 patients undergoing STC for IBD at our institution from 2007 through 2011 were identified. Patients undergoing open STC were compared with patients undergoing laparoscopic STC. Outcomes included 30-day morbidity, conversion to laparotomy, intraoperative blood loss, operative time, admission time, late onset complications and 30-day mortality. Results are presented as median values. A total of 57 patients underwent open STC (Group 1) and 42 patients laparoscopic STC (Group 2). Group 1 comprised 26 males and 31 females, with a median age of 35 years and a body mass index (BMI) of 23.2 kg/m2. Group 2 comprised 18 males and 24 females, with a median age of 34 years and a BMI of 23.5 kg/m2. Group 2 had less morbidity (42.9% versus 75.4%, p < 0.002), reduced blood loss (100 ml versus 200 ml, p < 0.001), longer operative time (193.5 min. versus 128 min., p < 0.001), shorter length of hospital stay (six days versus 16 days, p < 0.001) than Group 1. One patient died (Group 1). There was no difference in late onset complications and no conversions to laparotomy in the laparoscopic group. Laparoscopic STC has a longer operative time, but improves short-term outcomes compared with open surgery. not relevant. not relevant.

  14. The Place of Ultrasonography in the Evaluation of Rib Fractures

    OpenAIRE

    Fulya Bakılan; Gökhan Yüce; Ahmet Çağdaş Biçen; Tanju Keten

    2015-01-01

    Objective: The aim of this study was to investigate whether ultrasonography is superior to chest x-ray in detecting rib fractures in patients with minor blunt chest trauma and chest pain. Materials and Methods: Ultrasonography findings of 32 patients with minor blunt chest trauma showing no evidence of a rib fracture on anteroposterior chest x-rays, were documented. Presence of cortical discontinuities, acoustic shadows, reverberation artifacts, and hematoma by ultrasonography was...

  15. Computed tomography of hepatocellular carcinoma. Comparison with scintigraphy and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Kuniyuki; Nakata, Hajime; Honda, Hiroshi [University of Occupational and Environmental Health, Kitakyushu, Fukuoka (Japan)

    1983-09-01

    The detectability of hepatocellular carcinoma by computed tomography (CT) was evaluated on 76 cases. The detectability by plain CT was 93% with only slight improvement following a drip infusion of contrast medium. A comparison of scintigraphy, ultrasonography, and CT was also done on 63 cases. From the standpoint of the overall detectability of the tumor, CT was as good as ultrasonography or scintigraphy. Several cases were positive only on either CT or ultrasonography but no case was positive on scintigraphy alone. We believe that the combination of CT and ultrasonography is the most reliable as the screening method.

  16. Lower urinary tract symptoms after subtotal versus total abdominal hysterectomy: exploratory analyses from a randomized clinical trial with a 14-year follow-up.

    Science.gov (United States)

    Andersen, Lea Laird; Møller, Lars Mikael Alling; Gimbel, Helga

    2015-12-01

    Lower urinary tract symptoms (LUTS) are common after hysterectomy and increase after menopause. We aimed to compare subtotal with total abdominal hysterectomy regarding LUTS, including urinary incontinence (UI) subtypes, 14 years after hysterectomy. Main results from this randomized clinical trial have been published previously; the analyses covered in this paper are exploratory. We performed a long-term questionnaire follow-up of women in a randomized clinical trial (n = 319), from 1996 to 2000 comparing subtotal with total abdominal hysterectomy. Of the randomized women, ten had died and five had left Denmark; 304 women were contacted. For univariate analyses, a χ(2)-test was used, and for multivariate analyses, we used logistic regression. The questionnaire was answered by 197 (64.7 %) women (subtotal 97; total 100). More women had subjective stress UI (SUI) in the subtotal group (n = 60; 62.5 %) compared with the total group (n = 45; 45 %), with a relative risk (RR) of 1.39 [95 % confidence interval (CI) 1.06-1.81; P = 0.014]. No difference was seen between subtotal and total abdominal hysterectomy in other LUTS. Factors associated with UI were UI prior to hysterectomy, local estrogen treatment, and body mass index (BMI) > 25 kg/m(2). High BMI was primarily associated with mixed UI (MUI) and urgency symptoms. Predictors of bothersome LUTS were UI and incomplete bladder emptying. The difference in the frequency of subjectively assessed UI between subtotal and total abdominal hysterectomy (published previously) is caused by a difference in subjectively assessed SUI; UI prior to hysterectomy and high BMI are related to UI 14 years after hysterectomy. The trial is registered on clinicaltrials.gov under Nykoebing Falster County Hospital Record sj-268: Total versus subtotal hysterectomy: http://clinicaltrials.gov/ct2/show/NCT01880710?term=hysterectomy&rank=27.

  17. APPLICATION OF LAPAROSCOPIC ULTRASONOGRAPHY IN ADNEXAL OPERATIONS

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Objective:To explore the clinical value on application of laparoscopic ultrasonography (Lap US) in the adnexal operation. Methods:Eleven patients including 7 cases of tubal pregnancy, 3 cases of teratoma of ovary and 1 case of endometrial cyst of ovary were examined by LapUS, then operated with laparoscopy.Results:The results showed that the modality presented is a big progress over the traditional operative management for adnexal diseas. Conclusions:It is a good approach for micro-surgery in the adnexal operation by laparoscopy.

  18. Long-term Shifting Patterns in Quality of Life After Distal Subtotal Gastrectomy: Preoperative- and Healthy-based Interpretations.

    Science.gov (United States)

    Lee, Seung Soo; Chung, Ho Young; Kwon, Ohkyoung; Yu, Wansik

    2015-06-01

    The study assessed long-term shifting patterns in quality of life (QoL) after distal subtotal gastrectomy relative to an estimated healthy population QoL (HPQoL), and compared them to shifting patterns interpreted in terms of a preoperative QoL baseline. QoL data from 127 gastric cancer patients who underwent open distal subtotal gastrectomy were obtained at the preoperative period and at 6, 12, 18, 24, and 36 months after surgery. QoL data obtained from 127 age- and sex-adjusted healthy individuals were used to estimate HPQoL. The study used the European Organization for Research and Treatment of Cancer (EORTC) QoL Questionnaire Core 30 (QLQ-C30) and a gastric cancer module (QLQ-STO22) to assess QoL. Comparisons were made between preoperative-based and healthy-based interpretations of longitudinal QoL shifting patterns. Among the persistently deteriorated QoL variables indicated by the preoperative-based interpretation (physical functioning, role functioning, cognitive functioning, nausea and vomiting, dyspnea, diarrhea, dysphagia, eating restrictions, dry mouth, and body image), eating restrictions and body image concerns were the only factors indicated by a healthy-based interpretation. In this interpretation, financial difficulties were evident at the preoperative period and persisted for at least 36 months. When preoperative QoL was used as a baseline, decreased QoL due to financial difficulties was not revealed. Persistent QoL deterioration after distal subtotal gastrectomy is primarily due to financial difficulties, eating restrictions, and body image concerns. Preoperative-based interpretation of postoperative QoL may exaggerate the persistency of reduced QoL and conceal on-going QoL deterioration after surgery.

  19. Optically neuronavigated ultrasonography in an intraoperative magnetic resonance imaging environment.

    Science.gov (United States)

    Katisko, Jani P A; Koivukangas, John P

    2007-04-01

    To develop a clinically useful method that shows the corresponding planes of intraoperative two-dimensional ultrasonography and intraoperative magnetic resonance imaging (MRI) scans determined with an optical neuronavigator from an intraoperative three-dimensional MRI scan data set, and to determine the qualitative and the quantitative spatial correspondence between the ultrasonography and MRI scans. An ultrasound probe was interlinked with an ergonomic and MRI scan-compatible ultrasonography probe tracker to the optical neuronavigator used in a low-field intraoperative MRI scan environment for brain surgery. Spatial correspondence measurements were performed using a custom-made ultrasonography/MRI scan phantom. In this work, instruments to combine intraoperatively collected ultrasonography and MRI scan data with an optical localization method in a magnetic environment were developed. The ultrasonography transducer tracker played an important role. Furthermore, a phantom for ultrasonography and MRI scanning was produced. This is the first report, to our knowledge, regarding the possibility of combining the two most important intraoperative imaging modalities used in neurosurgery, ultrasonography and MRI scanning, to guide brain tumor surgery. The method was feasible and, as shown in an illustrative surgical case, has direct clinical impact on image-guided brain surgery. The spatial deviation between the ultrasonography and the MRI scans was, on average, 1.90 +/- 1.30 mm at depths of 0 to 120 mm from the ultrasonography probe. The overall result of this work is a unique method to guide the neurosurgical operation with neuronavigated ultrasonography imaging in an intraoperative MRI scanning environment. The relevance of the method is emphasized in minimally invasive neurosurgery.

  20. Ozone Therapy on Rats Submitted to Subtotal Nephrectomy: Role of Antioxidant System

    Directory of Open Access Journals (Sweden)

    José Luis Calunga

    2005-01-01

    Full Text Available Chronic renal failure (CRF represents a world health problem. Ozone increases the endogenous antioxidant defense system, preserving the cell redox state. The aim of this study is to evaluate the effect of ozone/oxygen mixture in the renal function, morphology, and biochemical parameters, in an experimental model of CRF (subtotal nephrectomy. Ozone/oxygen mixture was applied daily, by rectal insufflation (0.5 mg/kg for 15 sessions after the nephrectomy. Renal function was evaluated, as well as different biochemical parameters, at the beginning and at the end of the study (10 weeks. Renal plasmatic flow (RPF, glomerular filtration rate (GFR, the urine excretion index, and the sodium and potassium excretions (as a measurement of tubular function in the ozone group were similar to those in Sham group. Nevertheless, nephrectomized rats without ozone (positive control group showed the lowest RPF, GFR, and urine excretion figures, as well as tubular function. Animals treated with ozone showed systolic arterial pressure (SAP figures lower than those in the positive control group, but higher values compared to Sham group. Serum creatinine values and protein excretion in 24 hours in the ozone group were decreased compared with nephrectomized rats, but were still higher than normal values. Histological study demonstrated that animals treated with ozone showed less number of lesions in comparison with nephrectomized rats. Thiobarbituric acid reactive substances were significantly increased in nephrectomized and ozone-treated nephrectomized rats in comparison with Sham group. In the positive control group, superoxide dismutase (SOD and catalase (CAT showed the lowest figures in comparison with the other groups. However, ozone/oxygen mixture induced a significant stimulation in the enzymatic activity of CAT, SOD, and glutathione peroxidase, as well as reduced glutathione in relation with Sham and positive control groups. In this animal model of CRF, ozone

  1. Diagnostic value of ultrasonography in evaluation and management ...

    African Journals Online (AJOL)

    Results: Common causes of acute abdominal emergencies in pediatric patients as noted on ultrasonography included nonspecifi c pain (28%), abdominal abscess (21%), acute appendicitis (7%) and intussusception (7%). Ultrasonography was diagnostic in 45.2% cases and supportive in 12.3% of the cases. As for as the fi ...

  2. Nuclear medicine and ultrasonography in the acute cholecystitis diagnosis

    International Nuclear Information System (INIS)

    Schmillevitch, J.; Serson, D.; Camera, A.J.; Oliveira Nunes, J.E. de; Bazzo, J.M.B.

    1980-01-01

    Newer modalities for the evaluation of gallbladder include cholescintigraphy and ultrasonography. The IDA-Tc 99m presents functional informations with regard to cystic duct patency. The ultrasonography demonstrates the topographic anatomy of gallbladder, and morfologic alterations. Both analysis are preconized in acute cholecystitis. (Author) [pt

  3. The Place of Ultrasonography in the Evaluation of Rib Fractures

    Directory of Open Access Journals (Sweden)

    Fulya Bakılan

    2015-12-01

    Full Text Available Objective: The aim of this study was to investigate whether ultrasonography is superior to chest x-ray in detecting rib fractures in patients with minor blunt chest trauma and chest pain. Materials and Methods: Ultrasonography findings of 32 patients with minor blunt chest trauma showing no evidence of a rib fracture on anteroposterior chest x-rays, were documented. Presence of cortical discontinuities, acoustic shadows, reverberation artifacts, and hematoma by ultrasonography was proposed as the diagnostic criteria for detecting the rib fracture. Results: Rib fracture was detected in 20 patients (62.5% according to ultrasonography results. A mildly displaced fracture was detected in 7 patients (35%, hematoma was detected in 3 patients (15% and multiple fractures (in 5th, 6th, 7th, and 8th ribs were detected in 1 patient (5%. Conclusion: The results of our study showed that ultrasonography is superior to chest x-ray, in detecting rib fractures.

  4. Introital ultrasonography in female urinary incontinence

    Energy Technology Data Exchange (ETDEWEB)

    Weon, Young Cheol; Cho, Kyoung Sik; Lee, Jin Seong; Choi, Sang Hee; Kim, Keon Seok; Choo, Myung Soo [Ulsan Univ. Asan Medical Center, Seoul (Korea, Republic of)

    1996-06-01

    To evaluate the usefulness of introital ultrasonography in the assessment of female urinary incontinence. Introital ultrasonography was performed in fifteen with stress urinary incontinence(mean age 50) and six patients without symptoms of incontinence(mean age 37). Using a sagittal section of the anterior pelvis in the plane of the symphysis pubis the posterior urethrovesical angle, the pubourethral distance and the pubo-yregrak abgle were measured at rest and during stress(Valsalva's maneuver state). The student T-test and the ANOVA test were used in statistical analysis. The posterior urethrovesical angles of the controls were 125.3 deg ({+-}10.9) at rest and 125.7 deg ({+-}7.6) during stress. In the patients, the corresponding angles were 135.3 deg ({+-}11.3) and 139.6 deg({+-}10.8). The posterior urethrovesical angles increased 0.3 deg ({+-}4.7) in the controls and 5.6 deg ({+-}4.0) in the patients(p=0.018). In the controls, the pubo-urethral distances were 21.8 mm({+-}5.8) at rest and 18.2 mm({+-}7.1) during stress, while in the patients these distances were 18.4 mm({+-}3.9) and 12.6 mm({+-}4.4). The pubo-urethral distance decreased 3.5 mm ({+-}1.5) in the controls and 5.8 mm ({+-}2.3) in the patients(p=0.039). In the patients with mild incontinence(Grade I), the posterior urethrovesical angles increased 3.4 deg ({+-}2.8) : 132.3 deg ({+-}12.5) at rest and 135.6 deg (12.8) during stress. In the patients with moderate incontinence(Grade II), the angles increased 8.1 deg({+-}3.8) : 136.0 deg({+-}6.5) at rest and 144.1 deg({+-}5.9) during stress. The change of the posterior urethrovesical angle was related to the grade of urinary incontinence in the patients(p<0.05). There was no statistical significancy in the pubo-urethral angle (p=0.315). Introital ultrasonography may be useful for assessment of stress urinary incontinence.

  5. Ultrasonography of the pediatric hip and spine

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yeo Ryang; Koo, Joon Bun [Dept. of Radiology, Dongguk University Ilsan Hospital, Dongguk University College of Medicine, Goyang (Korea, Republic of)

    2017-07-15

    Ultrasonography (US) is a useful screening method for the diagnosis of developmental dysplasia of the hip (DDH) and congenital spinal anomalies in infants. In addition, US is a useful, noninvasive imaging modality for the diagnosis of transient synovitis in children. The early detection of DDH leads to a better prognosis without surgical intervention. Moreover, spinal US allows the detection of congenital malformations and can also demonstrate normal anatomy and normal variants that may resemble disorders. Therefore, radiologists should be familiar with the sonographic anatomy of the normal infant hip, scanning and measurement techniques for DDH, the US features of transient synovitis in children, spinal US techniques, and the US features of normal anatomical structures, normal variants, and congenital spinal anomalies.

  6. Current status of ultrasonography of the finger

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seun Ah; Kim, Baek Hyun [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of); Kim, Seon Jeong [Dept. of Radiology, Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Kim, Ji Na [Dept. of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon (Korea, Republic of); Park, Sun Young [Dept. of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of); Choi, Kyung Hee [Incheon Baek Hospital, Incheon (Korea, Republic of)

    2016-03-15

    The recent development of advanced high-resolution transducers has enabled the fast, easy, and dynamic ultrasonographic evaluation of small, superficial structures such as the finger. In order to best exploit these advances, it is important to understand the normal anatomy and the basic pathologies of the finger, as exemplified by the following conditions involving the dorsal, volar, and lateral sections of the finger: sagittal band injuries, mallet finger, and Boutonnière deformity (dorsal aspect); flexor tendon tears, trigger finger, and volar plate injuries (volar aspect); gamekeeper’s thumb (Stener lesions) and other collateral ligament tears (lateral aspect); and other lesions. This review provides a basis for understanding the ultrasonography of the finger and will therefore be useful for radiologists.

  7. Shoulder Ultrasonography: Performance and Common Findings

    Directory of Open Access Journals (Sweden)

    Diana Gaitini

    2012-01-01

    Full Text Available Ultrasound (US of the shoulder is the most commonly requested examination in musculoskeletal US diagnosis. Sports injuries and degenerative and inflammatory processes are the main sources of shoulder pain and functional limitations. Because of its availability, low cost, dynamic examination process, absence of radiation exposure, and ease of patient compliance, US is the preferred mode for shoulder imaging over other, more sophisticated, and expensive methods. Operator dependence is the main disadvantage of US examinations. Use of high range equipment with high resolution transducers, adhering to a strict examination protocol, good knowledge of normal anatomy and pathological processes and an awareness of common pitfalls are essential for the optimal performance and interpretation of shoulder US. This article addresses examination techniques, the normal sonographic appearance of tendons, bursae and joints, and the main pathological conditions found in shoulder ultrasonography.

  8. Current status of automated breast ultrasonography

    Directory of Open Access Journals (Sweden)

    Hee Jung Shin

    2015-07-01

    Full Text Available Breast ultrasonography (US is currently considered the first-line examination in the detection Epub ahead of print and characterization of breast lesions. However, conventional handheld US (HHUS has several limitations such as operator dependence and the requirement of a considerable amount of radiologist time for whole-breast US. Automated breast US (ABUS, recently approved by the United States Food and Drug Administration for screening purposes, has several advantages over HHUS, such as higher reproducibility, less operator dependence, and less required physician time for image acquisition. In addition, ABUS provides both a coronal view and a relatively large field of view. Recent studies have reported that ABUS is promising in US screening for women with dense breasts and can potentially replace handheld second-look US in a preoperative setting.

  9. Current status of ultrasonography of the finger

    Directory of Open Access Journals (Sweden)

    Seun Ah Lee

    2016-04-01

    Full Text Available The recent development of advanced high-resolution transducers has enabled the fast, easy, and dynamic ultrasonographic evaluation of small, superficial structures such as the finger. In order to best exploit these advances, it is important to understand the normal anatomy and the basic pathologies of the finger, as exemplified by the following conditions involving the dorsal, volar, and lateral sections of the finger: sagittal band injuries, mallet finger, and Boutonnière deformity (dorsal aspect; flexor tendon tears, trigger finger, and volar plate injuries (volar aspect; gamekeeper’s thumb (Stener lesions and other collateral ligament tears (lateral aspect; and other lesions. This review provides a basis for understanding the ultrasonography of the finger and will therefore be useful for radiologists.

  10. Ultrasonography of the pediatric hip and spine

    International Nuclear Information System (INIS)

    Kang, Yeo Ryang; Koo, Joon Bun

    2017-01-01

    Ultrasonography (US) is a useful screening method for the diagnosis of developmental dysplasia of the hip (DDH) and congenital spinal anomalies in infants. In addition, US is a useful, noninvasive imaging modality for the diagnosis of transient synovitis in children. The early detection of DDH leads to a better prognosis without surgical intervention. Moreover, spinal US allows the detection of congenital malformations and can also demonstrate normal anatomy and normal variants that may resemble disorders. Therefore, radiologists should be familiar with the sonographic anatomy of the normal infant hip, scanning and measurement techniques for DDH, the US features of transient synovitis in children, spinal US techniques, and the US features of normal anatomical structures, normal variants, and congenital spinal anomalies

  11. Prenatal diagnosis of hypophosphatasia congenita using ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Guguloth, Ashwitha [Dept. of Radiology, Bangalore Medical College and Research Institute, Bangalore (India); Aswani, Yashant; Anandpara, Karan Manoj [Dept. of Radiology, Seth G S Medical College and KEM Hospital, Mumbai (India)

    2016-01-15

    Congenital hypophosphatasia is a rare fatal skeletal dysplasia. Antenatal determinants of Epub ahead of print lethality include small thoracic circumference with pulmonary hypoplasia and severe micromelia. These features were present in the fetus of a 25-year-old female who came for an anomaly scan in her second trimester of pregnancy. Additional findings of generalized demineralization and osteochondral spurs led to the diagnosis of hypophosphatasia congenita. The pregnancy was terminated, and the findings were confirmed on autopsy. Common differential diagnoses with clues to diagnose the above mentioned condition have been discussed here. Early and accurate detection of this medical condition is important as no treatment has been established for this condition. Therefore, antenatal ultrasonography helps in diagnosing and decision making with respect to the current pregnancy and lays the foundation for the genetic counseling of the couple.

  12. Compression ultrasonography of the lower extremity with portable vascular ultrasonography can accurately detect deep venous thrombosis in the emergency department.

    Science.gov (United States)

    Crisp, Jonathan G; Lovato, Luis M; Jang, Timothy B

    2010-12-01

    Compression ultrasonography of the lower extremity is an established method of detecting proximal lower extremity deep venous thrombosis when performed by a certified operator in a vascular laboratory. Our objective is to determine the sensitivity and specificity of bedside 2-point compression ultrasonography performed in the emergency department (ED) with portable vascular ultrasonography for the detection of proximal lower extremity deep venous thrombosis. We did this by directly comparing emergency physician-performed ultrasonography to lower extremity duplex ultrasonography performed by the Department of Radiology. This was a prospective, cross-sectional study and diagnostic test assessment of a convenience sample of ED patients with a suspected lower extremity deep venous thrombosis, conducted at a single-center, urban, academic ED. All physicians had a 10-minute training session before enrolling patients. ED compression ultrasonography occurred before Department of Radiology ultrasonography and involved identification of 2 specific points: the common femoral and popliteal vessels, with subsequent compression of the common femoral and popliteal veins. The study result was considered positive for proximal lower extremity deep venous thrombosis if either vein was incompressible or a thrombus was visualized. Sensitivity and specificity were calculated with the final radiologist interpretation of the Department of Radiology ultrasonography as the criterion standard. A total of 47 physicians performed 199 2-point compression ultrasonographic examinations in the ED. Median number of examinations per physician was 2 (range 1 to 29 examinations; interquartile range 1 to 5 examinations). There were 45 proximal lower extremity deep venous thromboses observed on Department of Radiology evaluation, all correctly identified by ED 2-point compression ultrasonography. The 153 patients without proximal lower extremity deep venous thrombosis all had a negative ED compression

  13. Endoscopic Ultrasonography in the Diagnosis of Gastric Subepithelial Lesions

    Directory of Open Access Journals (Sweden)

    Eun Jeong Gong

    2016-09-01

    Full Text Available Subepithelial lesions occasionally found in the stomach of patients undergoing endoscopy may be either benign lesions or tumors with malignant potential. They may also appear due to extrinsic compression. Discrimination of gastric subepithelial lesions begins with meticulous endoscopic examination for size, shape, color, mobility, consistency, and appearance of the overlying mucosa. Accurate diagnosis can be achieved with endoscopic ultrasonography, which provides useful information on the exact size, layer-of-origin, and characteristic morphologic features to support a definitive diagnosis. Endoscopic ultrasonography also aids in the prediction of malignant potential, especially in gastrointestinal stromal tumors. Features of subepithelial lesions identified on endoscopic ultrasonography can be used to determine whether further diagnostic procedures such as endoscopic resection, fine needle aspiration, or core biopsy are required. Endoscopic ultrasonography is a valuable tool for diagnosis and clinical decision making during follow-up of gastric subepithelial lesions.

  14. Normal values for quantitative muscle ultrasonography in adults.

    NARCIS (Netherlands)

    Arts, I.M.P.; Pillen, S.; Schelhaas, H.J.; Overeem, S.; Zwarts, M.J.

    2010-01-01

    Ultrasonography can detect structural muscle changes caused by neuromuscular disease. Quantitative analysis is the preferred method to determine if ultrasound findings are within normal limits, but normative data are incomplete. The purpose of this study was to provide normative muscle

  15. Ultrasonography as a diagnostic method in addition to mammography

    Energy Technology Data Exchange (ETDEWEB)

    Otto, H.; Roer, E.

    1988-05-01

    By using ultrasonography in addition to mammography, experienced diagnosticians essentially enhance the safety of their diagnosis of mammary gland diseases. The same applies to gynecomastia, the condition after plastic surgery, and mastitis.

  16. A 15-year review of midface reconstruction after total and subtotal maxillectomy: part I. Algorithm and outcomes.

    Science.gov (United States)

    Cordeiro, Peter G; Chen, Constance M

    2012-01-01

    Reconstruction of complex midfacial defects is best approached with a clear algorithm. The goals of reconstruction are functional and aesthetic. Over a 15-year period (1992 to 2006), a single surgeon (P.G.C.) performed 100 flaps to reconstruct the following midfacial defects: type I, limited maxillectomy (n = 20); type IIA, subtotal maxillectomy with resection of less than 50 percent of the palate (n = 8); type IIB, subtotal maxillectomy with resection of greater than 50 percent of the palate (n = 8); type IIIA, total maxillectomy with preservation of the orbital contents (n = 22); type IIIB, total maxillectomy with orbital exenteration (n = 23); and type IV, orbitomaxillectomy (n = 19). Free flaps were used in 94 cases (94 percent), and pedicled flaps were used in six (6 percent). One hundred flaps were performed in 96 patients (69 males, 72 percent; 27 females, 28 percent); four patients underwent a second flap reconstruction due to recurrent disease (n = 4, 4 percent). Average patient age was 49.2 years (range, 13 to 81 years). Free-flap survival was 100 percent, with one partial flap loss (1 percent). Five patients suffered systemic complications (5.2 percent), and four died within 30 days of hospitalization (4.2 percent). Over 50 percent of patients returned to normal diet and speech. Almost 60 percent were judged to have an excellent aesthetic result. Free-tissue transfer offers the most effective and reliable form of reconstruction for complex maxillectomy defects. Rectus abdominis and radial forearm free flaps in combination with immediate bone grafting or as osteocutaneous flaps consistently provide the best functional and aesthetic results. Therapeutic, IV.

  17. Long term follow-up of Cushing's disease treated with reserpine and pituitary irradiation followed by subtotal adrenalectomy

    International Nuclear Information System (INIS)

    Murayama, Masanori; Yasuda, Keigo; Minamori, Yoshiaki; Mercado-Asis, L.B.; Morita, Hiroyuki; Miura, Kiyoshi; Yamakita, Noriyoshi.

    1994-01-01

    Subtotal adrenalectomy was given to 10 adult patients with Cushing's disease, concurrently with or following therapeutic regimen by long term reserpine administration and pituitary irradiation. In the present study, we describe long term follow-up results. Two patients died after the operation due to acute adrenal crisis and pneumonia, respectively. The other 8 patients achieved clinical and biochemical remissions and were followed for long term. Three patients relapsed 9, 14 or 17 years after achieving remission, two patients developed hypopituitarism 12 or 20 years after and one died of cerebral vascular accident at 64 years, 5 years after the remission. The remaining 2 patients maintained remission for 10 or 18 years, respectively. During the remission periods of 0.5 to 20 years with a mean of 10.1±6.7 years, 6 of 7 patients examined by 1 mg overnight dexamethasone test showed normal suppressibility of plasma cortisol. Provocative tests of plasma GH by 1-arginine infusion and/or insulin-induced hypoglycemia were performed in 6 patients in the early remission period. All of 5 patients in the arginine infusion test and 3 of 5 in the insulin-induced hypoglycemia test showed normal responses. Furthermore, to facilitate prediction of long term response or failure to our therapeutic regimen, long term reserpine administration and pituitary irradiation, pretreatment clinical and biochemical characteristics were analyzed retrospectively in 3 divided groups; the present 10 patients treated with reserpine and pituitary irradiation followed by subtotal adrenalectomy, 11 patients achieving long term remission treated by our regimen alone, and 7 patients failed with our regimen alone. There were no significant factors predictive of response to our regimen. (author)

  18. Ultrasonography as a better diagnostic efficiency in rib fracture

    OpenAIRE

    UZUN, Metin; BEKSAÇ, Burak; KARATAŞ, Adnan; KÜÇÜKDURMAZ, Fatih; KIRCALI, Bahar ANAYURDU; TETİK, Cihangir

    2013-01-01

    In this study, our aim was to demonstrate the need of use of ultrasonography in rib fractures in order not to face medicolegal problems. One hundred patients admitted to our emergency service with mild to moderate blunt thorax trauma were included in our study prospectively. The inclusion criteria were pain upon palpation of ribs, deep inspiration, coughing but no any other pathologies like a pneumothorax, hemothorax. All patients are evaluated with ultrasonography (USG) and direct X-rays. X-...

  19. Ultrasonography of the lower extremity veins: Anatomy and basic approach

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Kyu; Ahn, Kyung Sik; Kang, Chang Ho; Cho, Sung Bum [Dept. of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Ultrasonography is an imaging modality widely used to evaluate venous diseases of the lower extremities. It is important to understand the normal venous anatomy of the lower extremities, which has deep, superficial, and perforating venous components, in order to determine the pathophysiology of venous disease. This review provides a basic description of the anatomy of the lower extremity veins and useful techniques for approaching each vein via ultrasonography.

  20. Intraoperative ultrasonography in detection of hepatic metastases from colorectal cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael; Kronborg, Ole; Fenger, Claus

    1995-01-01

    PURPOSE: This study was designed to compare diagnostic accuracies of measuring liver enzymes, preoperative ultrasonography, surgical examination, and intraoperative ultrasonography for detection of liver metastases from colorectal cancer. METHODS: Blind, prospective comparisons of diagnostic...... examinations mentioned above were performed in 295 consecutive patients with colorectal cancer. An experienced ultrasonologist performed the preoperative examinations, and results were unknown to the other experienced ultrasonologist who performed the intraoperative examinations. The latter, also was unaware...

  1. Ultrasonography of the lower extremity veins: Anatomy and basic approach

    International Nuclear Information System (INIS)

    Lee, Dong Kyu; Ahn, Kyung Sik; Kang, Chang Ho; Cho, Sung Bum

    2017-01-01

    Ultrasonography is an imaging modality widely used to evaluate venous diseases of the lower extremities. It is important to understand the normal venous anatomy of the lower extremities, which has deep, superficial, and perforating venous components, in order to determine the pathophysiology of venous disease. This review provides a basic description of the anatomy of the lower extremity veins and useful techniques for approaching each vein via ultrasonography

  2. Acute diverticulitis of the terminal ileum: ultrasonography and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jewon; Hong, Seong Sook; Hwang, Ji Young; Kim, Hyun Joo; Chang, Yun Woo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    2015-01-15

    We describe a rare case of terminal ileal diverticulitis in a 68-year-old female with a day of history Epub ahead of print of right lower quadrant pain and tenderness, mimicking acute appendicitis. Ultrasonography revealed small sac-like out-pouching lesions with increased echogenicity of surrounding fat in thickened terminal ileum, suggesting inflamed diverticula. We diagnosed terminal ileal diverticulitis primarily by ultrasonography. The diagnosis was confirmed by subsequent computed tomography.

  3. Ultrasonography of the shoulder: pitfalls and variants

    International Nuclear Information System (INIS)

    Friedman, L.; Finlay, K.; Popowich, T.; Jurriaans, E.

    2002-01-01

    Ultrasonography (US) of the shoulder, particularly the evaluation of the rotator cuff, is the most common examination of the musculoskeletal system performed in most practices. Despite this, it remains one of the most difficult examinations to learn. There are many pitfalls and errors that can occur initially, but once mastered, US of the rotator cuff is one of the best methods available for diagnosing rotator cuff disease. The literature reports a 91%-95% sensitivity and close to 90% specificity and accuracy in the assessment of both partial and full thickness tears. This compares favourably with magnetic resonance imaging (MRI), where a more recent study reported an 84% sensitivity, 97% specificity and an accuracy of 93% for combined partial and full thickness tears of the rotator cuff. Advantages of US include low cost, easy access, high degree of accuracy in expert hands, ease of comparison with the opposite side, dynamic real-time examination, ability to focus on the exact site of the patient's pain and graded compression availability. It is for these reasons that we hope to outline the various pitfalls and common errors that can occur during the examination in a systematic fashion. It must also be pointed out that computed tomographic arthrography and magnetic resonance arthrography remain the investigations of choice for assessing labral disorders. (author)

  4. New endoscopic ultrasonography techniques for pancreticobiliary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kamata, Ken; Kitano, Masayuki; Omoto, Shunsuke; Kadosaka, Kumpei; Miyata, Takeshi; Minaga, Kosuke; Yamao, Kentaro; Imai, Hajime; Kudo, Masatoshii [Dept. of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka (Japan)

    2016-07-15

    Endoscopic ultrasonography (EUS) is widely used to evaluate pancreaticobiliary diseases, especially pancreatic masses. EUS has a good ability to detect pancreatic masses, but it is not sufficient for the differential diagnosis of various types of lesions. In order to address the limitations of EUS, new techniques have been developed to improve the characterization of the lesions detected by EUS. EUS-guided fine needle aspiration (EUS-FNA) has been used for diagnosing pancreatic tumors. In order to improve the histological diagnostic yield, a EUS-FNA needle with a core trap has recently been developed. Contrast-enhanced harmonic EUS is a new imaging modality that uses an ultrasonographic contrast agent to visualize blood flow in fine vessels. This technique is useful in the diagnosis of pancreatic solid lesions and in confirming the presence of vascularity in mural nodules for cystic lesions. EUS elastography analyzes several different variables to measure tissue elasticity, color patterns, and strain ratio, using analytical techniques such as hue-histogram analysis, and artificial neural networks, which are useful for the diagnosis of chronic pancreatitis and pancreatic cancer.

  5. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  6. Ultrasonography of hydronephrosis and renal masses

    International Nuclear Information System (INIS)

    Lee, Kyung Weon; Kim, Chong Gun; Kim, Yeon Jin; Rhee, Byung Chull

    1984-01-01

    We have analyzed ultrasonographic findings of 55 cases of hydronephrosis and 34 cases of renal masses. The results are as follows: 1. 55 cases of hydronephrosis revealed renal enlargement in 55 cases, separation of central echo complex in 27 cases, multiple anechoic areas radiating from the center in 25 cases and dilated renal pelvis in 24 cases. 2. Among the masses in 34 cases, simple renal cyst were 15 cases, polycystic kidney in 8 cases, hypernephroma in 8 cases, Wilm's tumor in 2 cases and agiomyolipoma in 1 case. 3. Simple renal cyst revealed single in 14 cases (93%) and well defined anechoic mass with posterior enhancement in all cases. 4. Polycystic kidney revealed bilateral irregular shaped renal enlargement and multiple anechoic cysts throughout the kidney. 2 cases (25%) involved liver. 5. 6 cases (75%) of hypernephroma revealed ill defined moderately echogenic mass without posterior enhancement. 6. All cases of Wilm's tumor revealed well defined large mixed echogenic mass in right kidney. 7. Angiomyolipoma revealed bilateral dense echogenic mass with large hemorrhage cyst in right kidney. 8. The ultrasonography is useful noninvasive diagnostic modality of evaluation of renal masses and hydronephrosis.

  7. En bloc kidney transplantation: ultrasonography assessment

    International Nuclear Information System (INIS)

    Arenal, F.; Ganado, T.; Merino, M.S.; Contreras, E.; Hernandez, J.; Prats, D.

    1997-01-01

    The objective of our study is to assess the utility of ultrasonography in the study of the complications associated with en bloc kidney transplantation. Twenty-three recipients of double transplants from donors under the age of 3 years were studied. Ultrasound (mode B: pulsed Doppler and color Doppler) was performed within the first three postoperative days and was repeated at 6 and 12 months. The morphology of the graft and renal blood flow were assessed, and the indices of pulsatility, resistance and acceleration were measured. Four patients required graft explanation: three due to massive hemorrhagic infarction and one due to venous thrombosis. Vascular complications were detected in five transplants (21.7%), urological complications in four (17.4%) and medical complications in two (8.7%). The most common vascular complication was unilateral renal artery stenosis. Color Doppler ultrasound diagnosed all the medical and urological complications and three of the five cases of vascular pathology (60%). Renal size was seen to be increased during the first postoperative year. The ultrasonographic study is more difficult to perform in en bloc kidney transplantation than in single kidney grafting: however, given its marked sensitivity in the detection of postransplantation complications. Doppler ultrasound is the imaging technique of choice in the determination of the cause of deteriorated kidney function. (Author) 15 refs

  8. Serial 2-point ultrasonography plus D-Dimer vs whole-leg color-coded doppler ultrasonography for diagnosing suspected symptomatic deep vein thrombosis - A randomized controlled trial

    NARCIS (Netherlands)

    Bernardi, Enrico; Camporese, Giuseppe; Buller, Harry R.; Siragusa, Sergio; Imberti, Davide; Berchio, Arrigo; Ghirarduzzi, Angelo; Verlato, Fabio; Anastasio, Raffaela; Prati, Carolina; Piccioli, Andrea; Pesavento, Raffaele; Bova, Carlo; Maltempi, Patrizia; Zanatta, Nello; Cogo, Alberto; Cappelli, Roberto; Bucherini, Eugenio; Cuppini, Stefano; Noventa, Franco; Prandoni, Paolo

    2008-01-01

    Context Patients with suspected deep vein thrombosis ( DVT) of the lower extremities are usually investigated with ultrasonography either by the proximal veins ( 2-point ultrasonography) or the entire deep vein system ( whole- leg ultrasonography). The latter approach is thought to be better based

  9. Granulomatous Prostatitis: Gray-scale Transrectal Ultrasonography and Color Doppler Ultrasonography Findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Jung; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae; Kim, Eui Jong [Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2007-12-15

    We report here three cases of granulomatous prostatitis. All cases were confirmed by a transrectal ultrasonography (TRUS)-guided core biopsy of the prostate. Two cases received intravesical BCG therapy for a bladder tumor, and one case had no known predisposing condition. Gray-scale TRUS showed low echoic nodules in the outer gland in all cases. Color Doppler ultrasonography (CDUS) showed several dot-like blood flows within the low echoic nodules in two cases and several dot-like blood flows and short linear blood flows within the low echoic nodules in one case. Gray-scale TRUS findings of granulomatous prostatitis are similar to findings of prostate cancer. On CDUS, several dot-like blood flows or short linear blood flows were noted within the low echoic nodules in patients with granulomatous prostatitis. If low echoic nodules with dot-like or short linear blood flows are noted in patients with genitourinary tract tuberculosis or previous BCG therapy, granulomatous prostatitis should be included in the differential diagnosis. However, a prostatic biopsy is required for a final diagnosis

  10. An analysis of 1018 cases of ultrasonography

    International Nuclear Information System (INIS)

    Kim, Chu Wan; Suh, Jeong Soo; Lee, Kwan Seh; Kim, Ki Hwan; Im, Chung Gie; Chang, Kee Hyun; Yeon, Kyung Mo; Han, Man Chung; Choo, Dong Woon

    1985-01-01

    Ultrasound is an especially helpful diagnostic tool in assessing various diseases in various organs as well as differentiating cystic masses from solid ones, with ease safety, reproducibility, and high accuracy. Authors analyzed total 1018 cases of ultrasonography that were studied in last seven months from March. 15. 1979 to October. 31. 1979, at the Department of Radiology, Seoul National University Hospital. The results were as follows: 1. Among the 1018 cases, 421 cases were male and 597 cases of female. The age distribution was from several months to 83 years, and 88% of all cases were in 20 to 69 years of age. 2. Sites of scanning; Liver, G.B. and biliary systems 376, thyroid 185, kidney 192, pelvis 121, abdomen 70, pancreas 48, eyeball 14, and other 12. 3. Hepatobiliary system 376; Normal 174, hepatomegaly 12, hepatoma 7, metastases 6, abscess 6, cirrhosis 2, hepatic cyst 1, hemangioma 1, agenesis of left lobe 1. 4. G.B. stones 106, cholecystitis 35, biliary tree dilatation 13, enlarged G.B. 7, C.B.D. stone 5, cystic duct stone 4, C.B.D. cancer 6, G.B. cancer 1, choledochal cyst 1, non-visualized G.B. 8. 5. Thyroid, 185; Nodule 147 -- solid 56, cystic 70, complex 21, Diffuse enlargement 29, normal scan 7, unidentified 2. 6. Pancreas, 48; Normal 17, pancreastitis 4, pancreatic cancer 22, pseudocyst 4, unidentified 1. 7. Abdomen 77 (excluding liver, G.B. and pancreas); Normal scan 31, solid tumor 14 - lymphoma group 12, mesenchyma origin 2, multiple lymph node enlargement 13, aortic aneurysm 4, retroperitoneal mass 2, subphrenic abscess 2, abdominal wall abscess 2, unknown solid mass 4, not contributory 4. 8. Kidney, 194, Normal scan 44, size and markings for biopsy 75, hydronephrosis 21, renal cyst 8, polycystic disease 8, solid renal tumor 10, renal stone 7, agenesis or hypoplasia 2, contracted kidney, both 7, enlarge kidney due to lymphoma and compensatory hyperplasia 5, renal tbc 2, perirenal abscess 1, perirenal hematoma 1, movable kidney 1, bladder tumor

  11. Endoscopic ultrasonography-guided rendezvous technique.

    Science.gov (United States)

    Tsuchiya, Takayoshi; Itoi, Takao; Sofuni, Atsushi; Tonozuka, Ryosuke; Mukai, Shuntaro

    2016-04-01

    Endoscopic retrograde cholangiopancreatography (ERCP) requires deep biliary cannulation. When deep biliary cannulation is failed, the endoscopic ultrasonography rendezvous technique (EUS-RV) is a useful salvage method. From the previous 15 articles that included 382 EUS-RV cases, the overall success rate of EUS-RV is 81 % with a complication rate of 10 %. In EUS-RV, the bile duct is punctured under EUS guidance and a guidewire is advanced into the duodenum via the papilla. The EUS scope is then switched to a duodenoscope and inserted into the bile duct over the guidewire exiting the papilla, or the guidewire is grasped with forceps and passed through the working channel; the catheter can then be inserted through the papilla over the wire. There are three puncture routes for EUS-RV: transgastric puncture of the intrahepatic bile duct (IHBD), transduodenal puncture of the extrahepatic bile duct (EHBD) via the proximal duodenum (D1), and transduodenal puncture of the EHBD via the second portion of the duodenum (D2). The puncture route for each patient should be selected based on the patient condition. GW selection for EUS-RV is critical, a hydrophilic GW is useful for this procedure. Although EUS-RV is now performed relatively routinely in a few high-volume centers, procedure standardization and the development of exclusive devices for EUS-RV are still underway. The development of exclusive devices for EUS-RV and prospective comparative studies with other salvage methods are needed to truly evaluate the procedure's usefulness and safety.

  12. Evaluation of Snake Bites with Bedside Ultrasonography

    Directory of Open Access Journals (Sweden)

    Josef E Jolissaint

    2018-04-01

    Full Text Available History of present illness: While watering his lawn, a 36-year-old man felt two sharp bites to his bilateral ankles. He reports that he then saw a light brown, 2-foot snake slither away from him. He came to the emergency department because of pain and swelling in his ankles and inability to bear weight. Physical examination revealed bilateral ankle swelling and puncture marks on his left lateral heel and medial right ankle. Palpation, passive flexion and extension elicited severe pain bilaterally. Blood work including prothrombin time (PT, partial thromboplastin time (PTT, international normalized ratio (INR, and fibrinogen were within normal limits. Consultation with Poison Control indicated the snake was likely a copperhead, which is a venomous snake whose bites rarely require antivenin. Significant findings: In this case, ultrasonography of the lateral surface of the left foot revealed soft tissue edema (red arrow and fluid collection (white asterisk adjacent to the extensor tendon (white arrow. The edematous area resembles cobblestones, with hypoechoic areas of fluid spanning relatively hyperechoic fat lobules. The tendon is surrounded by anechoic fluid, expanding the potential space in the sheath. No hyperechoic foreign objects were noted. Discussion: The patient was diagnosed with soft tissue injury and extensor tenosynovitis after a snake envenomation. Snake venom contains metalloproteinases and other enzymatic proteins that cause local tissue edema and necrosis.1 After a snake bite, ultrasound can be used to assess for retained fangs, soft tissue edema, tendon sheath fluid, muscle fasciculation, and injury to deeper musculature that may not be readily apparent on physical exam.2,3 Most patients with tenosynovitis will recover with immobilization of the joint and non-steroidal anti-inflammatory medications.4 Rarely, the tendon may become infected requiring antibiotics and surgical intervention.4 Topics: Ultrasound, snake envenomation

  13. II Brazilian consensus statement on endoscopic ultrasonography.

    Science.gov (United States)

    Maluf-Filho, Fauze; de Oliveira, Joel Fernandez; Mendonça, Ernesto Quaresma; Carbonari, Augusto; Maciente, Bruno Antônio; Salomão, Bruno Chaves; Medrado, Bruno Frederico; Dotti, Carlos Marcelo; Lopes, César Vivian; Braga, Cláudia Utsch; M Dutra, Daniel Alencar; Retes, Felipe; Nakao, Frank; de Sousa, Giovana Biasia; de Paulo, Gustavo Andrade; Ardengh, Jose Celso; Dos Santos, Juliana Bonfim; Sampaio, Luciana Moura; Okawa, Luciano; Rossini, Lucio; de Brito Cardoso, Manoel Carlos; Ribeiro Camunha, Marco Antonio; Clarêncio, Marcos; Lera Dos Santos, Marcos Eduardo; Franco, Matheus; Schneider, Nutianne Camargo; Mascarenhas, Ramiro; Roda, Rodrigo; Matuguma, Sérgio; Guaraldi, Simone; Figueiredo, Viviane

    2017-01-01

    At the time of its introduction in the early 80s, endoscopic ultrasonography (EUS) was indicated for diagnostic purposes. Recently, EUS has been employed to assist or to be the main platform of complex therapeutic interventions. From a series of relevant new topics in the literature and based on the need to complement the I Brazilian consensus on EUS, twenty experienced endosonographers identified and reviewed the pertinent literature in databases. The quality of evidence, strength of recommendations, and level of consensus were graded and voted on. Consensus was reached for eight relevant topics: treatment of gastric varices, staging of nonsmall cell lung cancer, biliary drainage, tissue sampling of subepithelial lesions (SELs), treatment of pancreatic fluid collections, tissue sampling of pancreatic solid lesions, celiac neurolysis, and evaluation of the incidental pancreatic cysts. There is a high level of evidence for staging of nonsmall cell lung cancer; biopsy of SELs as the safest method; unilateral and bilateral injection techniques are equivalent for EUS-guided celiac neurolysis, and in patients with visible ganglia, celiac ganglia neurolysis appears to lead to better results. There is a moderate level of evidence for: yield of tissue sampling of pancreatic solid lesions is not influenced by the needle shape, gauge, or employed aspiration technique; EUS-guided and percutaneous biliary drainage present similar clinical success and adverse event rates; plastic and metallic stents are equivalent in the EUS-guided treatment of pancreatic pseudocyst. There is a low level of evidence in the routine use of EUS-guided treatment of gastric varices.

  14. Ultrasonography in Gastroenterology: The Need for Training

    Directory of Open Access Journals (Sweden)

    João Pinto

    2018-02-01

    Full Text Available The use of ultrasonography (US as an imaging modality in medicine has spread across almost every clinical specialty. This diffusion is based on the simplicity, accessibility, portability and affordability of the technique producing real-time high-resolution images using non-ionising radiation. On the other hand, this trend also extended the technique to settings other than healthcare, such as public facilities, private houses or remote sites. This tendency can be observed worldwide, from developing countries to prestigious medical schools and tertiary referral hospitals. Furthermore, point-of-care US (POCUS, i.e., US executed at the patient’s bedside to obtain real-time objective information with diagnostic and clinical monitoring purposes or to guide invasive procedures, has been incorporated in many specialties. In gastroenterology, despite the essential role of endoscopy, clinical practice is highly dependent on non-endoscopic imaging techniques. However, as in other specialties, the indications of US in gastroenterology have been increasing steadily, covering a broad range of conditions. In response to the generalised employment of US by non-radiologists, institutions such as the European Federation of Societies for Ultrasound in Medicine and Biology and the Royal College of Radiologists issued recommendations to ensure high-quality practice. These theoretical and practical requisites include performing a certain number of examinations and mandatory skills in order to achieve certification to execute unsupervised US. Therefore, there is a need for modern gastroenterology to include US as a basic skill in its clinical practice. To ensure the provision of high-quality US, adequate instruction of future specialists should be guaranteed by the gastroenterology departments and required in the residency training programme.

  15. Evaluation of normal masseter muscles on ultrasonography

    International Nuclear Information System (INIS)

    Hwang, Hyoung Zoo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2008-01-01

    To assess the internal echo intensity and morphological variability of masseter muscles on ultrasonography and to establish diagnostic criterion of estimation. Participants consisted of 50 young adults (male 25, female 25) without pathologic conditions and with full natural dentitions. Sonographic examinations were done with real time ultrasound equipment as Logiq 500 (GE Medical Systems, Seoul, Korea) at 3 parts according to lines paralleling with ala-tragus line as reference line. The thickness and area of masseter muscles according to reference line in cross-sectional images were measured at rest and at maximum contraction. The visibility and width of the internal echogenic intensity of the masseter muscles were also assessed and the muscle appearance was classified into 4 types. Data were statistically analyzed by paired t-test and x2-test. 1. When comparing the thickness and area of masseter muscles concerning with gender, there was few significant difference between right and left sides, however, there were significant differences between males and females except for the greatest thickness of left side. 2. The changes of the greatest thickness and the area between rest and maximum contraction showed that the part of the least thickness manifested more increase at maximum contraction. 3. Each part the manifestations of the internal echogenic intensity of the masseter muscles were different depending on the locations. But there was no statistically significance. Changes of muscles thickness with contraction and internal echogenic intensity with locations showed great disparity within the masseter muscles, which will be diagnostic criteria for pathophysiologic and anatomic changes of masseter muscles.

  16. Transvaginal ultrasonography in first trimester of pregnancy and its comparison with transabdominal ultrasonography

    Directory of Open Access Journals (Sweden)

    Aneet Kaur

    2011-01-01

    Full Text Available Objectives : Examination of pregnant women in the first trimester with transvaginal ultrasonography with the aim to study various fetal development markers, e.g., gestation sac, yolk sac, fetal heart motion, CRL length, and fetal anatomy in both normal and abnormal pregnancies. Comparative evaluation of transvaginal ultrasonography vis-ΰ-vis transabdominal scanning in the study of first trimester of pregnancy and its complications. To assess the relative merits and demerits of transvaginal ultrasonography in comparison with the transabdominal technique. Materials and Methods : The study will be conducted on 50 females patients during the first trimester of pregnancy. The study population will consist of both normal and abnormal pregnancies. These patients will be included on the basis of suspicion of or proven pregnancy of duration up to 12 weeks from LMP. The evaluation of the patients will include the following: Record of patients obstetrical history and clinical examination, record of pregnancy test and relevant investigations, ultrasonic examination of pregnancy. (a Transabdominal ultrasound scanning will be done with moderately distended bladder by using real time scanners with low frequency probe (3/3.5 MHz; (b transvaginal sonography will be done with the real-time sector scanner using high-frequency endovaginal probe (5/7.5 MHz, after the patient voids urine. Relevant images will be taken by using the multiformat automatic camera. Results and Conclusions : In the study of 46 normal intrauterine pregnancies, TVS showed additional information in 36 patients (78.3% as compared to TAS, in detection of gestation sac, yolk sac, double bleb sign, or better visualization of embryonic anatomy. In the abnormal pregnancy (n=17, TVS provided more information in 11 cases (64.9%, which included detection of embryonic demise, yolk sac, double bleb sign, or subchorionic hemorrhage. Regarding ectopic gestations (n=7, TVS gave additional information in 5

  17. Evaluation of abdominal trauma by computed tomography and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Kim, Sang Jin; Lee, Jong Tae; Yoo, Hyung Sik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1986-06-15

    Out of 75 patients who were admitted to our hospital because of abdominal trauma and were undergone the procedures such as ultrasonography and/or CT scan within 24 hours of abdominal trauma due to suspected abdominal organ injury. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. 1. In the abdominal organ injury, solid organ injury consists of 8 cases of spleen laceration, 1 of splenic subcapsular hematoma, 7 of hepatic laceration, 7 of pancreas laceration, 3 of renal laceration, and 3 of subcapsular hematoma of kidney. 2. In addition, there were 7 bowel and/or mesenteric laceration, 2 diaphragmatic hernia, and 1 urethral rupture. 3. 2 cases of retroperitoneal hematoma and 1 case in which hemo peritoneum occurred without abdominal organ injury were confirmed by follow-up CT or ultrasonography. 4. In all of the 4 patients with multiple organ injury, pancreatic laceration was associated. 5. In abdominal trauma patients, ultrasonography or CT can be used to survey rapidly the entire abdomen for possible associated injury, and be of great help to clinicians in identifying the patients who need immediate surgery or in minimizing the incidence of unnecessary emergency abdominal exploration.

  18. Evaluation of abdominal trauma by computed tomography and ultrasonography

    International Nuclear Information System (INIS)

    Lee, Do Yun; Kim, Sang Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1986-01-01

    Out of 75 patients who were admitted to our hospital because of abdominal trauma and were undergone the procedures such as ultrasonography and/or CT scan within 24 hours of abdominal trauma due to suspected abdominal organ injury. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. 1. In the abdominal organ injury, solid organ injury consists of 8 cases of spleen laceration, 1 of splenic subcapsular hematoma, 7 of hepatic laceration, 7 of pancreas laceration, 3 of renal laceration, and 3 of subcapsular hematoma of kidney. 2. In addition, there were 7 bowel and/or mesenteric laceration, 2 diaphragmatic hernia, and 1 urethral rupture. 3. 2 cases of retroperitoneal hematoma and 1 case in which hemo peritoneum occurred without abdominal organ injury were confirmed by follow-up CT or ultrasonography. 4. In all of the 4 patients with multiple organ injury, pancreatic laceration was associated. 5. In abdominal trauma patients, ultrasonography or CT can be used to survey rapidly the entire abdomen for possible associated injury, and be of great help to clinicians in identifying the patients who need immediate surgery or in minimizing the incidence of unnecessary emergency abdominal exploration.

  19. Evaluation of breast symptoms with mammography and ultrasonography

    Directory of Open Access Journals (Sweden)

    Emine Devolli Disha

    2011-12-01

    Full Text Available Introduction: Aim of the study was to discern which are more frequent symptoms presented in malign and benign masses diagnosed by mammography and ultrasonography.Methods: Our study group consisted of 546 female patients, with breast symptoms such as palpable lumps (40.8%, pain in the breast (26%, localized lumpiness or nodularity (13.7%, nipple retraction (11.2%, nipplebloody discharge (5.1% and redness and swelling of the breast (3.1%. All 546 patients were examined by ultrasonography and mammography. Biopsy was performed according to the findings of mammography and ultrasonography.Results: In breast cancer detection ultrasonography showed an efficiency of 79.4% compared to 55.0% for mammography in detecting breast lump, in the case of nipple retraction mammography showed an efficiency of 89.1% compared to 80.4% for ultrasound, while the lowest efficiency for mammography was in the cases with localized lumpiness or nodularity 17.1% compared to 45.7% for ultrasound. In detecting fibrocystic changes where the most common symptoms was pain, ultrasonography showed an efficiency of 99.3 % compared to 84.2 % for mammography.Conclusions: Our study confirmed that breast lumps are detectable in the majority of patients with breast cancer. The most frequent symptoms in patient with benign lesions were pain or localized discomfort. The diagnostic accuracy for carcinomas of the breast and for benign lesions according to symptoms was higher for ultrasound than for mammography.

  20. Ovarian blood supply in women of reproductive age and echo-graphic evaluation of influence of subtotal hysterectomy on it

    Directory of Open Access Journals (Sweden)

    Т. V. Lescheva

    2017-12-01

    Full Text Available Purpose of the study. To study the peculiarities of ovarian blood supply after subtotal hysterectomy in the reproductive age. Materials and methods of research. In accordance with the purpose and objectives of the work 150 women of reproductive age were included, there were 4 groups. 125 patients suffered from uterine leiomyoma, 100 of whom had a hysterectomy (HE – a supravaginal uterus amputation (SUA, which corresponds to a subtotal HE (SHE. Results. When examining a group of healthy women of the control group, we determined the average volume of the ovaries – 5.2 ± 0.2 cm2, which did not differ from the average size for healthy women of reproductive age. When studying the structure of the ovaries and their size, several large ovarian dimensions (6.0 ± 0.4 cm2 and the presence of cystic changes in some of them have attracted attention in patients with leiomyoma of the uterus. In addition to the study of the anatomical characteristics of the ovaries, we investigated the blood flow in the ovarian arteries, and the study of blood flow was carried out according to the phases of the menstrual cycle in the women of the control group, as well as in patients with uterine leiomyoma – one year before and after the operation. Conclusions. Ultrasound showed a gradual decrease in volume as the duration of the postoperative period increased. Duplex scanning with the determination of indices characterizing the blood flow revealed a slight deterioration in the blood supply of the ovaries within 1 year after removal of the uterus compared with patients with uterine leiomyoma and healthy women of similar age. IER was the most sensitive index, which was the first to react to the change in the tone of the vascular bed. In more than half of operated patients we did not find any cyclic changes in the blood flow in the ovarian artery, which was characteristic of healthy patients of reproductive age. Change in blood flow is early and more sensitive sign of

  1. Cholescintigraphy and ultrasonography in patients suspected of having acute cholecystitis

    DEFF Research Database (Denmark)

    Lauritsen, K B; Sommer, W; Hahn, L

    1988-01-01

    The diagnostic power of combined cholescintigraphy and ultrasonography was tested in 67 patients suspected of having acute cholecystitis; of these, 42 (63%) had acute cholecystitis. The predictive value of a positive scintigraphy (PVpos) was 95% and that of a negative (PVneg) was 91% (n = 67......). The PVpos and PVneg of ultrasonography were 89% and 75%, respectively (n = 54), and these values did not achieve statistical significance when compared with those for scintigraphy. Inconclusive tests were 10% and 11%, respectively, but in no patient were both scintigraphy and ultrasonography inconclusive...... that in patients suspected of having acute cholecystitis cholescintigraphy should be the first diagnostic procedure performed. If the scintigraphy is positive, additional ultrasonographic detection of gallstones makes the diagnosis almost certain. If one diagnostic modality is inconclusive, the other makes a fair...

  2. Ultrasonography and radiography of the canine postpartum uterus

    International Nuclear Information System (INIS)

    Pharr, J.W.; Post, K.

    1992-01-01

    A vulvovaginal discharge following parturition in a bitch is often a cause of concern to owners and clinicians, especially if whelping was complicated in any way. Ultrasonography could potentially distinguish between normal and abnormal postpartum uterine states because the uterine wall and luminal contents can be imaged in detail. Five normal bitches were examined to determine the normal ultrasonographic appearance of the postpartum uterus and the sensitivity of ultrasonography in detecting the involuting uterus, comparing this sensitivity with that of radiography. Ultrasonography was done at 1, 4, 8, 12, 18 and 24 days postpartum, radiography at 1, 4, 8, 12 and 18 days postpartum. By 12 days postpartum, the uterus could not be seen on radiographs, while at 24 days postpartum the uterus was still sonographically identifiable. The ultrasonographic characteristics of the involuting uterus are described

  3. The diagnostic value of ultrasonography in the gyneocological emergency

    International Nuclear Information System (INIS)

    Su Hui; Chen Fanghua; Peng Xiulan

    2006-01-01

    Objective: To evaluate the ultrasonography in the diagnosis and differential diagnosis of gynecologic emergency. Methods: 138 patients suffered from gynecologic emergency were examined with ultrasonography. The images were retrospectively reviewed and compared with pathologic or clinical results. Results: The total correct diagnostic rate was 89.1%. Among 138 cases of gynecologic emergency, there were 45 cases of ectopic pregnancy, 27 cases of ruptured corpus luteum, 24 cases of torsion of ovarian cyst, and 42 cases of acute pelvic inflammation. The correct diagnostic rates were 91.1%, 81.5%, 87.5%, 92.2%, respectively. Conclusion: The ultrasonography plays an important role in the diagnosis of gynecological emergency. When the US findings were not typical, the clinical history, symptoms and HCG level should be considered in order to avoid misdiagnosis. (authors)

  4. Modified vs. standard D2 lymphadenectomy in distal subtotal gastrectomy for locally advanced gastric cancer patients under 70 years of age.

    Science.gov (United States)

    Zhang, Chun-Dong; Zong, Liang; Ning, Fei-Long; Zeng, Xian-Tao; Dai, Dong-Qiu

    2018-01-01

    The present study was conducted to investigate the prognosis and survival of patients with locally advanced gastric cancer who underwent distal subtotal gastrectomy with modified D2 (D1+) and D2 lymphadenectomy, under 70 years of age. The five-year overall survival rates of 390 patients were compared between those receiving D1+ and D2 lymphadenectomy. Univariate and multivariate analyses were used to identify factors that correlated with prognosis and lymph node metastasis. Tumor size (P=0.039), pT stage (P=0.011), pN stage (PD2 lymphadenectomy removes sufficient lymph nodes to improve staging accuracy and survival. Therefore, D2 lymphanectomy is recommended in distal subtotal gastrectomy for locally advanced gastric cancer, especially for cancers of larger size and higher pT stage.

  5. Subtotal gastrectomy with conventional D2 lymphadenectomy for carcinoma of the distal gastric portion: A retrospective cohort study on clinical outcomes

    Directory of Open Access Journals (Sweden)

    Povilas Kavaliauskas

    2016-03-01

    Conclusions: A R0 type distal subtotal gastrectomy with standard D2 lymphadenectomy for a histologically proven invasive adenocarcinoma of the distal gastric portion without distant metastasis offers acceptable postoperative morbidity and mortality, and considerably high overall cumulative 5-year survival rate. The probability of cumulative survival decreases five times when the ratio between metastatic and examined lymph nodes is > 0.25.

  6. Serial comparisons of quality of life after distal subtotal or total gastrectomy: what are the rational approaches for quality of life management?

    Science.gov (United States)

    Park, Sujin; Chung, Ho Young; Lee, Seung Soo; Kwon, Ohkyoung; Yu, Wansik

    2014-03-01

    The aims of this study were to make serial comparisons of the quality of life (QoL) between patients who underwent total gastrectomy and those who underwent distal subtotal gastrectomy for gastric cancer and to identify the affected scales with consistency. QoL data of 275 patients who were admitted for surgery between September 2008 and June 2011 and who underwent subtotal gastrectomy or total gastrectomy were obtained preoperatively and postoperatively at 3, 6, 9, 12, 18, and 24 months. The Korean versions of the European Organization for Research and Treatment (EORTC) Quality of Life Questionnaire Core 30 (QLQ-C30) and the gastric cancer specific module, the EORTC QLQ-STO22, were used to assess QoL. QoL, as assessed by the global health status/QoL and physical functioning, revealed a brief divergence with worse QoL in the total gastrectomy group 3 months postoperatively, followed by rapid convergence. QoL related to restrictive symptoms (nausea/vomiting, dysphagia, reflux, and eating restrictions) and dry mouth was consistently worse in the total gastrectomy group during the first 2 postoperative years. The general QoL of patients after gastrectomy is highly congruent with subjective physical functioning, and the differences between patients who undergo total gastrectomy and subtotal gastrectomy are no longer valid several months after surgery. In order to further reduce the differences in QoL between patients who underwent total gastrectomy and subtotal gastrectomy, definitive preoperative informing, followed by postoperative symptomatic management, of restrictive symptoms in total gastrectomy patients is the most rational approach.

  7. Challenges in a larger bladder replacement with cell-seeded and unseeded small intestinal submucosa grafts in a subtotal cystectomy model.

    Science.gov (United States)

    Zhang, Yuanyuan; Frimberger, Dominic; Cheng, Earl Y; Lin, Hsueh-Kung; Kropp, Bradley P

    2006-11-01

    To evaluate small intestinal submucosa (SIS), unseeded or seeded, as a possible augmentation material in a canine model of subtotal cystectomy. In all, 22 male dogs had a 90% partial cystectomy and were then divided into three groups. At 1 month after the initial cystectomy, dogs in group 1 (unseeded, six) and group 2 (seeded, six) received a bladder augmentation with a corresponding SIS graft. The dogs in group 3 (ten) received no further surgery and were considered the surgical control group. All dogs were evaluated before and after surgery with blood chemistry, urine culture, intravenous urography, cystograms and cystometrograms. After surgery (at 1, 5 and 9 months), the bladders were examined using routine histology and immunohistochemistry. All 22 dogs survived the subtotal cystectomy, and 18 survived their intended survival period. One dog, in group 2 (seeded), was killed at 1 month after augmentation due to bladder perforation caused by a large piece of incompletely absorbed SIS. Three other dogs (group 1, two; and group 2, one) were killed within 2 months after augmentation due to bladder obstruction by stones. Group 1 and group 2 SIS grafts had moderate to heavy adhesion, graft shrinkage, and some had bone and calcification at the graft site. Histologically, there was limited bladder regeneration in both groups. Interestingly, dogs in group 3 at 1 month after cystectomy (when group 1 and 2 received their augmentations) had severely shrunken bladders and histologically had severe inflammation, fibroblast infiltration and muscle hypertrophy. These results verify the subtotal cystectomy model. The use of seeded or unseeded SIS in a subtotal cystectomy model does not induce the same quality and quantity of bladder regeneration that is seen in the 40% non-inflammatory cystectomy model. This study provides important insights into the process of regeneration in a severely damaged bladder. The results led us to re-evaluate the critical elements required for a

  8. Adverse cardiac effects of exogenous angiotensin 1-7 in rats with subtotal nephrectomy are prevented by ACE inhibition.

    Directory of Open Access Journals (Sweden)

    Louise M Burrell

    Full Text Available We previously reported that exogenous angiotensin (Ang 1-7 has adverse cardiac effects in experimental kidney failure due to its action to increase cardiac angiotensin converting enzyme (ACE activity. This study investigated if the addition of an ACE inhibitor (ACEi to Ang 1-7 infusion would unmask any beneficial effects of Ang 1-7 on the heart in experimental kidney failure. Male Sprague-Dawley rats underwent subtotal nephrectomy (STNx and were treated with vehicle, the ACEi ramipril (oral 1mg/kg/day, Ang 1-7 (subcutaneous 24 μg/kg/h or dual therapy (all groups, n = 12. A control group (n = 10 of sham-operated rats were also studied. STNx led to hypertension, renal impairment, cardiac hypertrophy and fibrosis, and increased both left ventricular ACE2 activity and ACE binding. STNx was not associated with changes in plasma levels of ACE, ACE2 or angiotensin peptides. Ramipril reduced blood pressure, improved cardiac hypertrophy and fibrosis and inhibited cardiac ACE. Ang 1-7 infusion increased blood pressure, cardiac interstitial fibrosis and cardiac ACE binding compared to untreated STNx rats. Although in STNx rats, the addition of ACEi to Ang 1-7 prevented any deleterious cardiac effects of Ang 1-7, a limitation of the study is that the large increase in plasma Ang 1-7 with ramipril may have masked any effect of infused Ang 1-7.

  9. Feasibility and nutritional impact of laparoscopy-assisted subtotal gastrectomy for early gastric cancer in the upper stomach.

    Science.gov (United States)

    Kosuga, Toshiyuki; Hiki, Naoki; Nunobe, Souya; Noma, Hisashi; Honda, Michitaka; Tanimura, Shinya; Sano, Takeshi; Yamaguchi, Toshiharu

    2014-06-01

    Laparoscopy-assisted total gastrectomy (LATG) is commonly performed for early gastric cancer (EGC) in the upper stomach; however, the incidence of anastomotic complications remains high, and postoperative nutritional status is not satisfactory. This study aimed to evaluate the feasibility and nutritional impact of a novel surgical procedure, laparoscopy-assisted subtotal gastrectomy (LAsTG). This was a retrospective study of 167 patients with EGC in the upper stomach. Of these, 57 patients underwent LAsTG, while 110 patients underwent LATG. Postoperative change in body weight, and serum concentration of albumin (Alb) and total protein (TP) were compared between the LAsTG and LATG groups. Analysis of covariance (ANCOVA) was used to assess the influence of potential confounding factors. Frequency of anastomotic complications was significantly higher in the LATG group (16.3 %) than in the LAsTG group (5.3 %, P = 0.040). Postoperative recovery of body weight at 12 months after surgery was significantly better in the LAsTG group (89.8 ± 1.4 %) than in the LATG group (82.1 ± 1.0 %, P nutritional status.

  10. Comparing survival outcomes of gross total resection and subtotal resection with radiotherapy for craniopharyngioma: a meta-analysis.

    Science.gov (United States)

    Wang, Guoqing; Zhang, Xiaoyang; Feng, Mengzhao; Guo, Fuyou

    2018-06-01

    Recent studies suggest that subtotal resection (STR) followed by radiation therapy (RT) is an appealing alternative to gross total resection (GTR) for craniopharyngioma, but it remains controversial. We conducted a meta-analysis to determine whether GTR is superior to STR with RT for craniopharyngioma. A systematic search was performed for articles published until October 2017 in the PubMed, Embase, and Cochrane Central databases. The endpoints of interest are overall survival and progression-free survival. Pooled hazard ratios (HRs) and corresponding 95% confidence intervals (CIs) were calculated using a fixed or random-effects model. The data were analyzed using Review Manager 5.3 software. A total of 744 patients (seven cohort studies) were enrolled for analyses. There were no significant differences between the GTR and STR with RT groups when the authors compared the pooled HRs at the end of the follow-up period. Overall survival (pooled HR = 0.76, 95% CI: 0.46-1.25, P = 0.28) and progression-free survival (pooled HR = 1.52, 95% CI: 0.42-5.44, P = 0.52) were similar between the two groups. The current meta-analysis suggests that GTR and STR with RT have the similar survival outcomes for craniopharyngioma. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Transition pattern and mechanism of B-lymphocyte precursors in regenerated mouse bone marrow after subtotal body irradiation.

    Directory of Open Access Journals (Sweden)

    Deping Han

    Full Text Available Little is known about the effects of ionizing radiation on the transition and the related signal transduction of progenitor B cells in the bone marrow. Thus, using an NIH Swiss mouse model, we explored the impact of ionizing radiation on the early stage of B-cell development via an examination of the transition of CLP to pro-B to pre-B cells within bone marrow as a function of radiation doses and times. Our results showed that while the total number of bone marrow lymphoid cells at different stages were greatly reduced by subtotal body irradiation (sub-TBI, the surviving cells continued to transition from common lymphoid progenitors to pro-B and then to pre-B in a reproducible temporal pattern. The rearrangement of the immunoglobulin heavy chain increased significantly 1-2 weeks after irradiation, but no change occurred after 3-4 weeks. The rearrangement of the immunoglobulin light chain decreased significantly 1-2 weeks after sub-TBI but increased dramatically after 3-4 weeks. In addition, several key transcription factors and signaling pathways were involved in B-precursor transitions after sub-TBI. The data indicate that week 2 after irradiation is a critical time for the transition from pro-B cells to pre-B cells, reflecting that the functional processes for different B-cell stages are well preserved even after high-dose irradiation.

  12. The usefulness of levin tube inserted drip infusion spiral CT: comparison with conventional method in subtotal gastrectomy patients

    International Nuclear Information System (INIS)

    Park, Young Jin; Kim, Young Hwan; Yoon, Jung Hee; Cha, Soon Joo; Kim, Jeong Sook; Kim, Sung Rok; Hur, Gham; Rhim, Hyun Chul

    1998-01-01

    The purpose of this study is to access the usefulness of newly designed Levin tube inserted drip infusion spiral CT for the evaluation of remnant stomach and anastomosis site in patients who have undergone subtotal gastrectomy for stomach cancer. A new technique named Levin tube inserted drip infusion spiral CT was used to prospectively study 23 patients. A 16Fr Levin tube was inserted into the remnant stomach; 500 ml of tap water was drip infused just before CT scanning and an additional 500 ml of water was infused during IV contrast injection. Water was infused by gravity, using a water bottle suspended at a height of 90 cm (Group A). The 31 patients who underwent conventional spiral CT scanning immediately after the divided ingestion of 900 ml diluted gastrografin were selected as a control group (Group B). The anatomic delineation of the anastomosis site was graded by two radiologists as excellent (3), good(2), fair (1) or poor (0). To evaluate the degree of distension, the maximal diameters of remnant stomach and the anastomosis site, and the thickness of the stomach wall, were also measured. In patients who had undergone subtobal gastrectomy, Levin tube inserted drip infusion spiral CT showed excellent anatomic delineation of the site of anastomosis and remnant stomach. We found that because it increases the distension of remnant stomach and the anastomosis site, this technique is effective for the evaluation of postoperative stomach. (author). 10 refs., 2 tabs., 3 figs

  13. A case of severe aplastic anemia transplanted with allogeneic bone marrow following premedication by cyclophosphamide and subtotal lymphoid irradiation

    International Nuclear Information System (INIS)

    Kato, Koji; Yoshida, Miyako; Iwamura, Haruki; Mizuno, Tomohisa; Matsuoka, Hiroshi; Hotta, Tomomitsu; Kodera, Yoshihisa

    1985-01-01

    A one-year old girl was admitted to the Okayama Red Cross Hospital on August 22, 1984 with fever and multiple furuncles. She was pale; peripheral blood examination revealed pancytopenia, and bone marrow aspiration showed a very hypoplastic marrow with only 4.5 percent of hematopoietic cells. Immediately anabolic steroid was administered but it failed to improve her hematological condition. She had a HLA identical brother and was transferred to the Department of Pediatrics of Nagoya University Hospital for bone marrow transplantation. After gut sterilization and an intravenous catheter were prepared, she received 500 mg of cyclophosphamide for successive 4 days followed by 750 rads of subtotal lymphoid irradiation, and 5 x 10 9 bone marrow cells were infused from her brother. Bone marrow aspiration on day 13 showed an increase in hematopoietic cells, and engraftment was confirmed by examinations of red blood cell type and sex chromosome. Hepatic transaminase increased from day 19, but was normalized by cessation of methotrexate and administration of betamethasone. Decreased immunoglobulin level after transplantation has recovered, and inverted OKT 4/8 ratio has also been normalized. After one year from transplantation, she is in a good hematological condition and is enjoying her life without any complication. (author)

  14. [Abdominal ultrasonography in patients with diabetes mellitus. Part 1: Liver].

    Science.gov (United States)

    Jenssen, C; Pietsch, C; Gottschalk, U; Barreiros, A P; Teufel, A; Cui, X W; Dietrich, C F

    2015-04-01

    In patients with diabetes mellitus, abdominal ultrasonography is the appropriate diagnostic technique to detect and to follow-up secondary and accompanying diseases of the liver, the kidneys, the pancreas, the gastrointestinal tract and of abdominal vessels. Moreover, pancreatic and hepatic diseases may be realized which are of etiological importance for diabetes mellitus. Based on a systematic survey of the published literature, this review in 3 parts will describe the value of abdominal ultrasonography in patients with diabetes mellitus. Part 1 deals with the diagnostic relevance and particular findings of ultrasonographic methods in hepatic manifestations and complications of diabetes mellitus. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Traumatic Lumbar Hernia Diagnosed by Ultrasonography: A Case Report

    International Nuclear Information System (INIS)

    Lee, Kwang Lae; Yim, Yoon Myung; Lim, Oh Kyung; Park, Ki Deok; Choi, Chung Hwan; Lee, Ju Kang

    2009-01-01

    Traumatic lumbar hernia describes the extrusion of intraperitoneal or extraperitoneal contents through a defect in the posterolateral abdominal wall caused by a trauma. This is a rare entity and usually diagnosed by computed tomography. A 64-year-old male received an injury on his cervical spinal cord after an accident in which he fell down. He complained of a mass on his left posterolateral back area. We diagnosed the mass as a traumatic lumbar hernia by ultrasonography and confirmed it by computed tomography. We conclude that the ultrasonography can be a useful diagnostic tool for traumatic lumbar hernia

  16. Traumatic Lumbar Hernia Diagnosed by Ultrasonography: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang Lae; Yim, Yoon Myung; Lim, Oh Kyung; Park, Ki Deok; Choi, Chung Hwan; Lee, Ju Kang [Gachon University of Medicine and Science, Incheon (Korea, Republic of)

    2009-12-15

    Traumatic lumbar hernia describes the extrusion of intraperitoneal or extraperitoneal contents through a defect in the posterolateral abdominal wall caused by a trauma. This is a rare entity and usually diagnosed by computed tomography. A 64-year-old male received an injury on his cervical spinal cord after an accident in which he fell down. He complained of a mass on his left posterolateral back area. We diagnosed the mass as a traumatic lumbar hernia by ultrasonography and confirmed it by computed tomography. We conclude that the ultrasonography can be a useful diagnostic tool for traumatic lumbar hernia

  17. Paediatric ultrasonography of the liver, hepatobiliary tract and pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Rijn, R.R. van, E-mail: r.r.vanrijn@amc.uva.nl [Department of Radiology, Emma Children' s Hospital – Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Nievelstein, R.A.J. [Department of Radiology, Wilhelmina Children' s Hospital – University Medical Center, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2014-09-15

    In the field of paediatric radiology ultrasonography (US) is the most versatile imaging tool available. Children in general, by virtue of their body composition, are excellent candidates for US exams in whom abdominal anatomy and pathology can be visualised in great detail. The fact that during the US study a clinical history can be obtained strongly adds to the value of the US exam. This does require investment in time and expertise and ideally a paediatric radiologist performing the exam. In this review the role of ultrasonography (US) of the liver, biliary tract and pancreas in children is discussed.

  18. Ultrasonography of hydronephrosis in the newborn: A practical review

    International Nuclear Information System (INIS)

    Choi, Young Hun; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One

    2016-01-01

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn

  19. Ultrasonography of hydronephrosis in the newborn: a practical review

    Science.gov (United States)

    2016-01-01

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn. PMID:27156562

  20. Ultrasonography of hydronephrosis in the newborn: A practical review

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Hun; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Children' s Hospital, Seoul (Korea, Republic of)

    2016-07-15

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn.

  1. Multidetector CT Evaluation of Food Stasis in Remnant Stomach and Body Fat Change after Subtotal Gastrectomy by Laparoscopic versus Open Abdominal Approach

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ah Young; Yu, Jeong Sik; Choi, Seung Ho; Chung, Jae Joon; Kim, Joo Hee; Kim, Ki Whang [Yonsei University College of Medicine, Gangnam Severance Hospital, Seoul (Korea, Republic of)

    2013-01-15

    This study aimed to compare the degree of gastric food stasis and following body fat changes after laparoscopic subtotal gastrectomy (LSTG) versus open subtotal gastrectomy (OSTG). For 284 consecutive gastric cancer patients who underwent subtotal gastrectomy (213 LSTG and 71 OSTG), the one-year follow-up CT images were reviewed retrospectively. The characteristics of gastric stasis was divided into 5 degrees (0, no residue; 1, small secretion; 2, poorly-defined amorphous food; 3, well-delineated measurable food; 4, bezoar-like food). The residual food volume was calculated for the patients with degree 3 or 4 gastric stasis. Postoperative visceral, subcutaneous, and total fat changes were measured on CT and were correlated with the residual food volume. The LSTG group showed higher degrees of gastric stasis [degree 3 (LSTG, 15.0%; OSTG, 9.9%), degree 4 (LSTG, 6.5%; OSTG, 2.8%)] (p = 0.072). The mean residual food volume of the LSTG group was larger than that of the OSTG group (13779 cc versus 6295 cc) (p = 0.059). Postoperative abdominal fat change was not significantly different between the 2 groups and was not correlated with the residual food volume. LSTG tends to develop gastric stasis more frequently compared with OSTG, but gastric stasis might hardly affect the postoperative body fat status.

  2. Ultrasonography and computer tomography in the diagnosis of certain abdominal diseases

    International Nuclear Information System (INIS)

    Wawrzynek, Z.

    1981-01-01

    Ultrasonography and computer tomography in the diagnosis of digestive tract and spleen diseases as well as traumas are compared. It is concluded that ultrasonography is nearly as usefull as computer tomography. (author)

  3. Killian-Jamieson Diverticulum Mimicking a Thyroid Nodule on Ultrasonography: A Case Report

    International Nuclear Information System (INIS)

    Kim, Eun Soo; Lee, Kwan Seop; Yoon, Hoi Soo; Jeon, Eui Yong; Hwang, Hee Sung; Koh, Sung Hye; Kim, Min Jeong; Jang, Kyung Mi; Lee, Myung Jun; Lee, Yul

    2007-01-01

    Thyroid ultrasonography is widely used for diagnosis and cytologic evaluation of thyroid nodules. We encountered a case of Killian-Jamieson diverticulum, which was differentiated from a thyroid nodule using ultrasonography

  4. Atlas-based knee osteophyte assessment with ultrasonography and radiography

    DEFF Research Database (Denmark)

    Koski, J M; Kamel, Ayadi; Waris, P

    2016-01-01

    OBJECTIVES: To investigate intra- and inter-reader agreement of ultrasonography (US) and conventional radiography (CR) for the evaluation of osteophyte presence and size within the tibiofemoral joint. In addition, to correlate these findings with arthroscopic degeneration of the articular cartila...

  5. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2012-01-01

    The wrist region is one of the most complex joints of the human body. It is prone to deformity and functional impairment in juvenile idiopathic arthritis (JIA), and is difficult to examine clinically. The aim of this study was to evaluate the role of ultrasonography (US) with Doppler in diagnosis...

  6. An unanticipated diagnosis with bedside ultrasonography in patients ...

    African Journals Online (AJOL)

    Although abdominal pain is a common presentation in emergency departments, rectus sheath hematoma (RSH) is among the rarest diagnosis. Here we present 2 cases of RSH likely caused by coughing due to upper respiratory tract infection. The two described cases were diagnosed by bedside ultrasonography and ...

  7. The accuracy rate of Alvarado score, ultrasonography, and ...

    African Journals Online (AJOL)

    Objective: In this study, we aim to compare the relationship between the Alvarado score, ultrasonography, and multislice computerized tomography (CT) findings used for the diagnosis of the patients who presented to our emergency unit with clinical features suggestive of acute appendicitis. Materials and Methods: ...

  8. Imaging in hematology. Part 1: Ultrasonography and conventional radiology

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    Applications of conventional ultrasonography techniques (B-mode or real time) in oncohematology are presented. The newer adaptations (in particular colour Doppler) provide incremental advantages that support their inclusion in the imaging techniques available to modern hematology. Conventional radiologic studies include chest and bone X-ray, gastrointestinal contrast examination and bipedal lymphangiography

  9. Impact of magnetic resonance urography and ultrasonography on ...

    African Journals Online (AJOL)

    Background: (1) To evaluate the diagnostic value of magnetic resonance urography (MRU) in comparison with ultrasonography (US) to determine the extent of upper urinary tract dilation and (2) to evaluate the impact of MRU on therapy management. Materials and Methods: From January 2005 to December 2010, ...

  10. In-utero diagnosis of Norrie disease by ultrasonography.

    Science.gov (United States)

    Redmond, R M; Vaughan, J I; Jay, M; Jay, B

    1993-03-01

    Obstetric ultrasonography of an obligate Norrie disease carrier revealed bilateral retinal detachments in a third trimester male fetus. Postnatal examination confirmed the diagnosis of Norrie disease. DNA linkage analysis with the markers L1.28 and MAO had been uninformative for this family. This report suggests that retinal detachment occurs late in the gestation of the affected fetus.

  11. Primary muscular hydatid: preoperative diagnosis Throught computerized tomography and ultrasonography

    International Nuclear Information System (INIS)

    Macho Fernandez, J.M.; Marin Cardenas, M.A.; Mazas Artasona, L.; Lample Lacasa, C.; Otero Sierra, C.; Hernandez Navarrete, M.J.; Gomez-Pereda, R.

    1995-01-01

    Primary muscular hydatid disease, is extremely rare,- but not exceptional-, comparatively with other atypical localization. In this article the authors revised 474 patients with hydatid disease over a ten years period. Three cases of primary muscular localization were found. The ultrasonography and computed tomography facilitates the preoperative diagnosis. (Author) 40 refs

  12. Evaluation of the hip joint by computed tomography and ultrasonography

    International Nuclear Information System (INIS)

    Anda, S.

    1991-04-01

    In patients with dysplastic hips the acetabular angles and femoral anteversion were determined in a CT investigation. Comparative investigations of femoral anteversion were made by ultrasonography and biomedical radiography. The investigations are described and the general conclusions discussed. 205 refs., 15 figs., 10 tabs

  13. Short-term treatment with diminazene aceturate ameliorates the reduction in kidney ACE2 activity in rats with subtotal nephrectomy.

    Directory of Open Access Journals (Sweden)

    Elena Velkoska

    Full Text Available Angiotensin converting enzyme (ACE 2 is an important modulator of the renin angiotensin system (RAS through its role to degrade angiotensin (Ang II. Depletion of kidney ACE2 occurs following kidney injury due to renal mass reduction and may contribute to progressive kidney disease. This study assessed the effect of diminazine aceturate (DIZE, which has been described as an ACE2 activator, on kidney ACE2 mRNA and activity in rats with kidney injury due to subtotal nephrectomy (STNx. Sprague Dawley rats were divided into Control groups or underwent STNx; rats then received vehicle or the DIZE (s.c. 15 mg/kg/day for 2 weeks. STNx led to hypertension (P<0.01, kidney hypertrophy (P<0.001 and impaired kidney function (P<0.001 compared to Control rats. STNx was associated with increased kidney cortical ACE activity, and reduced ACE2 mRNA in the cortex (P<0.01, with reduced cortical and medullary ACE2 activity (P<0.05, and increased urinary ACE2 excretion (P<0.05 compared to Control rats. Urinary ACE2 activity correlated positively with urinary protein excretion (P<0.001, and negatively with creatinine clearance (P=0.04. In STNx rats, DIZE had no effect on blood pressure or kidney function, but was associated with reduced cortical ACE activity (P<0.01, increased cortical ACE2 mRNA (P<0.05 and increased cortical and medullary ACE2 activity (P<0.05. The precise in vivo mechanism of action of DIZE is not clear, and its effects to increase ACE2 activity may be secondary to an increase in ACE2 mRNA abundance. In ex vivo studies, DIZE did not increase ACE2 activity in either Control or STNx kidney cortical membranes. It is not yet known if chronic administration of DIZE has long-term benefits to slow the progression of kidney disease.

  14. A New Suggestion for the Radiation Target Volume After a Subtotal Gastrectomy in Patients With Stomach Cancer

    International Nuclear Information System (INIS)

    Nam, Heerim; Lim, Do Hoon; Kim, Sung; Kang, Won Ki; Sohn, Tae Sung; Noh, Jae Hyung; Kim, Yong Il; Park, Chan Hyung; Park, Chul Keun; Ahn, Yong Chan; Huh, Seung Jae

    2008-01-01

    Purpose: To compare treatment results between the use of two different radiation fields including and excluding remnant stomach and suggest new target volumes excluding remnant stomach after subtotal gastrectomy (STG) in patients with stomach cancer. Methods and Materials: We retrospectively analyzed 291 patients treated with adjuvant chemoradiotherapy after STG and D2 dissection at the Samsung Medical Center, Seoul, South Korea. Eighty-three patients registered from 1995 to 1997 underwent irradiation according to the INT 0116 protocol that recommended the inclusion of remnant stomach within the target volume (Group A). After this period, we excluded remnant stomach from the target volume for 208 patients (Group B). Median follow-up was 67 months. Results: Treatment failure developed in 93 patients (32.0%). Local and regional recurrence rates for Group A vs. Group B were 10.8% vs. 5.3% (p = not significant) and 9.6% vs. 6.3% (p = not significant), and recurrence rates for remnant stomach were 7.2% vs. 1.4% (p = 0.018), respectively. Overall and disease-free survival rates were not different between the two groups. Grade 3 or 4 vomiting and diarrhea developed more frequently in Group A than Group B (4.8% vs. 1.4% and 6.0% vs. 1.9%, respectively; p = 0.012; p < 0.001). Conclusion: Exclusion of remnant stomach from the radiation field had no effect on failure rates or survival, and a low complication rate occurred in patients treated excluding remnant stomach. We suggest that remnant stomach be excluded from the radiation target volume for patients with stomach cancer who undergo STG and D2 dissection

  15. Extension of radiotherapy (involved field vs subtotal nodal) after short-term chemotherapy in early-stage Hodgkin's disease (ESHD)

    International Nuclear Information System (INIS)

    Zanini, M.; Bonfante, V.; Soncini, F.; Di Russo, A.; Santoro, A.; Viviani, S.; Devizzi, L.; Gasparini, M.; Tesoro, Tess J.D.; Valagussa, P.; Bonadonna, G.

    1995-01-01

    Aims of this study were to avoid staging laparotomy, to improve the results of radiotherapy (RT) alone by a combined modality approach, to evaluate the optimal extent of RT after short-term chemotherapy (CT) and to reduce the long-term toxicity in patients cured for ESHD. From (2(90)) to (1(95)), 110 consecutive patients with clinical stage I (bulky and/or B), IIA, IIA bulky and IIEA entered a randomized trial comparing subtotal nodal irradiation (STNI) vs involved field radiotherapy (IFRT), both after short-term chemotherapy (ABVD for 4 cycles). The doses of RT were 30 Gy to uninvolved and 36 Gy to involved sites, respectively. With a median follow-up of 38 mos., the main results in 96 evaluable patients (stage I: 13 pts., stage II: 83 pts., median age 28 yrs., range 17-64) are as reported below. Most patients achieved complete remission (CR) after CT (92%), while 8 partial responders attained CR with RT (IFRT 5 pts., STNI 3 pts.). Four stage II patients relapsed (IFRT 2, pts., STNI 2 pts.), mainly in extranodal or not irradiated sites. Up-to-date the most remarkable toxicities include: acute myocardial infarction (1%), aspecific EKG changes (5%), reductions in pulmonary function tests (most mild and/or transient) in 45%, subclinical or clinical hypothyroidism 26% (only in pts. irradiated to the neck), 3 cases of azoospermia in 23 evaluable patients (13%) and transient amenorreha in(1(44)) patients. No second malignancies have been so far observed. The results of this study seem to indicate that 4 courses of ABVD plus RT are an effective treatment in clinical ESHD, with moderate long-term toxicities. In almost 10% of patients RT changed partial into complete remission. Should these results be confirmed on a longer follow-up, IFRT will definitely replace STNI in a combined modality treatment

  16. Cost-effectiveness analysis of antithyroid drug therapy, 131I therapy and subtotal thyroidectomy for Graves' disease

    International Nuclear Information System (INIS)

    Yano, Fuzuki; Watanabe, Sadahiro; Hayashi, Katsumi; Kita, Tamotsu; Yamamoto, Masayoshi; Kosuda, Shigeru; Tanaka, Yuji

    2007-01-01

    The objective of this study was to assess the cost-effectiveness of antithyroid drug (ATD) therapy vs. radioiodine therapy (RIT) vs. subtotal thyroidectomy (STT) by calculating expected lifelong cost and utility based on Graves' disease patients' responses to questionnaires using a decision-tree sensitivity analysis and relevant variables. The decision-tree sensitivity analysis to determine expected lifelong cost and utility in Graves' disease patients was designed on the basis of the 4 competing strategies consisting of: (1) ATD therapy plus RIT strategy, (2) ATD therapy plus STT strategy, (3) low-fixed-dose (185 MBq) RIT alone strategy, and (4) high-fixed-dose (370 MBq) RIT alone strategy. One-way sensitivity analysis was designed in the ATD therapy plus RIT strategy, for replacement with RIT in place of ATD, ranging from a 1% incidence of ATD side effects to 30%. The low-fixed-dose RIT alone strategy was least costly, and the high-fixed-dose RIT alone strategy most costly. The lifelong utility of high-fixed-dose RIT alone strategy with a 5% rate of discounting was highest (lifelong utility for 30 years: 15.2/patient), and the utility of the ATD plus RIT strategy with 1% side effects of the ATD was lowest (14.1/patient). The cost-effectiveness ratio was lowest (yen 5 008/utility) in a low-fixed-dose RIT alone strategy. In conclusion, a low-fixed-dose RIT alone strategy is preferred treatments in view of cost-effectiveness ratio, and RIT should be used more widely in Japan. (author)

  17. Retrospective comparison of abdominal ultrasonography and radiography in the investigation of feline abdominal disease

    Science.gov (United States)

    Won, Wylen Wade; Sharma, Ajay; Wu, Wenbo

    2015-01-01

    Abdominal radiography and ultrasonography are commonly used as part of the initial diagnostic plan for cats with nonspecific signs of abdominal disease. This retrospective study compared the clinical usefulness of abdominal radiography and ultrasonography in 105 feline patients with signs of abdominal disease. The final diagnosis was determined more commonly with ultrasonography (59%) compared to radiography (25.7%). Ultrasonography was also able to provide additional clinically relevant information in 76% of cases, and changed or refined the diagnosis in 47% of cases. Based on these findings, ultrasonography may be sufficient as an initial diagnostic test for the investigation of feline abdominal disease. PMID:26483582

  18. Avaliação da função fagocitária em remanescentes de esplenectomia subtotal e auto-implante esplênico autógeno Assessment of phagocytic function in remnants of subtotal spleen implantation

    Directory of Open Access Journals (Sweden)

    Andy Petroianu

    2003-03-01

    Full Text Available Para diminuir os efeitos adversos da esplenectomia total, abordagens conservadoras devem ser tentadas, quando for possível. Esplenectomia subtotal e auto-implantes esplênicos são boas alternativas nessa situação. O objetivo do presente estudo foi comparar as funções fagocitárias do pólo superior remanescente de esplenectomia subtotal e de tecido esplênico implantado no omento maior. Esta investigação foi conduzida em 35 ratos Holtzman adultos de ambos os sexos. Todos os animais foram submetidos a esplenectomia subtotal preservando o pólo superior suprido pelos vasos esplenogástricos e a auto-implante do segmento esplênico removido, no omento maior. A função fagocitária foi verificada por dois métodos diferentes: cintilografia com enxofre coloidal marcado com 99mTc e contagem, ao microscópio, de macrófagos que continham carbono coloidal. Durante os três primeiros meses, a fagocitose foi maior no pólo superior remanescente. Após esse período, não houve diferença entre o pólo superior e o auto-implante. Concluindo, o remanescente de esplenectomia subtotal e o auto-implante esplênico mantêm a função de filtração do baço mediante remoção de partículas coloidais do sangue.In order to diminish the adverse effects of total splenectomy, a conservative approach must be performed whenever possible. Subtotal splenectomy and splenic autotransplantation are good alternatives in such cases. The purpose of the present study was to compare the phagocytic function of the upper pole remnant of subtotal splenectomy and of autologous spleen tissue implanted into the greater omentum. This investigation was carried out on 35 adult Holtzman rats of both sexes. All animals were submitted to subtotal splenectomy, preserving the upper pole supplied by the splenogastric vessels and autotransplantation of the removed splenic segment on the greater omentum. The phagocytic function of the splenic remnants was verified by two different

  19. Ultrasonography and cholescintigraphy in the diagnostics of biliary tree

    International Nuclear Information System (INIS)

    Iskrenova, Zh.; Minchev, D.

    1997-01-01

    The purpose is to determine whether a reversed sequence of bile flow (i.e. small bowel followed by gallbladder) could serve as an indicator of chronic cholecystitis. 43 hepatobiliary scans were reviewed retrospectively with attention to the relative order of gallbladder and small bowel appearance during the first hour. Usually radioactive bile flows initially into the gallbladder followed by passage into the small bowel. The scintigraphic findings were correlated with results from gallbladder histopathology and gallbladder ultrasonography in 11 patients. The specificity of a reversed sequence for chronic cholecystitis was 82% using ultrasonography and 100% for histopathology. The visualization of gallbladder after the small bowel appears in patients referred for possible biliary tract disease predicts chronic cholecystitis (author)

  20. Role of ultrasonography in the ocular and the orbital diseases

    International Nuclear Information System (INIS)

    Kim, S. R.; Kim, K. S.; Lee, Y. C.; Park, S. S.

    1984-01-01

    With conventional methods including orbital arteriography, orbital venography, penumoobitography and positive contrast orbitography, imaging of eyeball and orbit is not only difficult, invasive or expensive but also nonspecific in result. Ultrasonography provides safe, specific and reliable way to obtain image of eyeball and orbit. Fifty six ultrasonograms of 50 patients which were referred under the impression of various ophthalmic diseases were analyzed. 1. Sixteen cases were normal. 2. Ocular diseases were 26 cases and extraocular orbital diseases were 8 cases. 3. Among the ocular diseases, 9 foreign body cases, 6 retinal detachment cases, 5 vitreous hemorrhage 4. Among the extraocular orbital diseases, 6 pseudotumor cases, 1 pseudolymphoma, 1 eyelid cyst case were diagnosed. 5. Ultrasonic findings were specific enough to differentiated from diseases and well corresponded with clinical and pathological diagnosis. 6. It can be concluded that ultrasonography is one of the most reliable imaging method in ocular and extraocular orbital diseases

  1. Potentialities of computed tomography and ultrasonography in colonic cancer

    International Nuclear Information System (INIS)

    Gorshkov, A.N.

    2001-01-01

    Data of examination of 59 patients with colonic cancer were used to consider the potentialities of transabdominal, transrectal ultrasonography and X-ay compound tomography and to assess their value in diagnosing colonic cancer, including its minor forms. Ultrasound and computed tomographic semiotics of colonic cancer and determines a place of the above techniques in the algorithm of radiation and instrumental studies are described. Inclusion of these techniques into the diagnostic algorithm may solve a range of differentially diagnostic problems and allows a preliminary analysis to be made in a tumor lesion according to the International TNM classification. Ultrasonography and X-ray computed tomography should be included into a range of basic methods for diagnosis of colonic cancer [ru

  2. Ultrasonography of Midline Scalp Masses : A Preliminary Report

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyo Kyeong; Lee, Ho Kyu; Choi, Choong Gon; Kim, Kyeong Sook; Jung, Seung Mun; Suh, Dae Chul [Asan Medical Center University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    We report our ultrasonographic experiences in the evaluation of small midline scalp masses. Ultrasonography was performed in four patients with midline scalp mass less than 3cm and its connecting tract into the cranialcavity. Ultrasonographic findings were correlated with pathologic results. There were three cephaloceles and one cystic lymph angioma. Two encephalomenin-goceles, located in occipital region, were mixed cystic and solid lesions and one atretic meningocele in parietal region was a solid lesion. Ultrasonogram of all three cases showed calvarial defect and connecting tract into the cranial cavity. On the contrary, a cystic lymph angioma in occipital region was a purely cystic mass without an associated calvarial defect. We suppose that ultrasonography could be a useful screening tool in the evaluation of midline scalp masses

  3. Transrectal ultrasonography of anorectal disease: advantages and disadvantages

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Ju [Dept. of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2015-01-15

    Transrectal ultrasonography (TRUS) has been widely accepted as a popular imaging modality for Epub ahead of print evaluating the lower rectum, anal sphincters, and pelvic floor in patients with various anorectal diseases. It provides excellent visualization of the layers of the rectal wall and of the anatomy of the anal canal. TRUS is an accurate tool for the staging of primary rectal cancer, especially for early stages. Although magnetic resonance imaging is a modality complementary to TRUS with advantages for evaluating the mesorectum, external sphincter, and deep pelvic inflammation, three-dimensional ultrasonography improves the detection and characterization of perianal fistulas and therefore plays a crucial role in optimal treatment planning. The operator should be familiar with the anatomy of the rectum and pelvic structures relevant to the preoperative evaluation of rectal cancer and other anal canal diseases, and should have technical proficiency in the use of TRUS combined with an awareness of its limitations compared to magnetic resonance imaging.

  4. Henoch-Schonlein purpura: ultrasonography of scrotal and penile involvement

    Directory of Open Access Journals (Sweden)

    Youngsik Lim

    2015-04-01

    Full Text Available Testicular or scrotal involvement has been reported in children with Henoch-Schonlein purpura (HSP, but there are very few reports on penile involvement. We report the initial and follow-up ultrasonographic findings of scrotal and penile involvement of HSP in a 5-year-old boy. On ultrasonography, scrotal soft tissue thickening and epididymal swelling with increased vascularity were noted, and on the penis, a focal mass-like lesion appeared on the dorsal surface of the distal penis, having a hypoechoic mass-like appearance without visible vascular flow on a Doppler study. After 2 days of treatment, follow-up ultrasonography showed normal scrotum and penis with a resolved soft tissue mass-like lesion. Therefore, we think that HSP ultrasonographic findings involving the scrotum and penis might help to diagnose scrotal and penile involvement in a case of HSP and to avoid unnecessary medication and/or surgical procedures.

  5. Diagnostic ultrasonography in cattle with abdominal fat necrosis.

    Science.gov (United States)

    Tharwat, Mohamed; Buczinski, Sébastien

    2012-01-01

    This study describes the ultrasonographic findings in 14 cows with abdominal fat necrosis. Ultrasonography of the abdomen revealed the presence of heterogeneous hyperechoic masses and hyperechoic omentum with localized masses floating in a hypoechoic peritoneal fluid. A hyperechogenic rim was imaged around both kidneys. The intestines were coated with hyperechoic capsules and the intestinal lumens were constricted. Ultrasonographic examination of the pancreatic parenchyma showed an overall increased echogenicity which was homogenously distributed in 3 cases. A diagnosis of abdominal fat necrosis was made with ultrasound-guided biopsy of the echogenic masses, and thereafter at postmortem examination. Results from this study demonstrate the efficacy of ultrasonography as an imaging modality for antemortem diagnosis of abdominal lipomatosis in cattle. To the authors' knowledge, this study is the first that illustrates ultrasonographic findings in cattle affected with abdominal lipomatosis.

  6. Interobserver Variation of the Renal Length Measurement on Ultrasonography

    International Nuclear Information System (INIS)

    Jeong, Yoong Ki; Chung, Hye Weon; Kim, Tae Sung; Ryoo, Jae Wook; Kim, Tae Kyoung; Kim, Seung Hyup

    1995-01-01

    We assessed interobserver variation in the measurement of the renal length on ultrasonography. Ultrasonographic examinations were performed in randomly selected 50 patients. The maximallenhths of both kidneys were measured with calipers during the scanning from frozen images by three observers in a blinded fashion. There was a relatively constant tendency of an observer to measure a renal length either longer or shorter than the other observer(Kendall coefficient>0.05). Average interobserver variations were 0.51 cm (±0.42 cm) in right kidney and 0.53 cm (±0.41 cm) in left kidney and were within 1 cm in 91% right and 89% of left kidney. Interobserver variation about 1cm should be considered in the measurement of the renal length on ultrasonography

  7. On use of ultrasonography in obstetrics and gynecology

    International Nuclear Information System (INIS)

    Woo, Kwang Suk; Lee, Yong Woo

    1984-01-01

    Ultrasonography is playing an very important in diagnosis of normal pregnancy and the other diseases in the fields of obstetrics and gynecology. It is mainly used B-mode and Real time linear scan for pregnancy such as fetal movement during its early stage, fetal position, placenta location and biparietal diameter during its middle stage, and amniotic fluid and placenta previa during its late stage, as well as tumor accompanying pregnancy. Ultrasonography has been extensively used in the fields of obstetrics and gynecology for obtaining detailed images of soft tissues without hazard to the fetus and pregnant woman. In view of the need for its professionalism of high degree of skill, this treatise will introduce clinical instances and images obtained in the sonography room of the Seoul National University Hospital

  8. Reliable and Valid Assessment of Point-of-care Ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt

    2015-01-01

    physicians' OSAUS scores with diagnostic accuracy. RESULTS: The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores......OBJECTIVE: To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. BACKGROUND: POC US is increasingly used by clinicians and is an essential part of the management of acute surgical...... conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. METHODS: Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different...

  9. [Significance of hypo-osmolar diets for oral nutrition build-up in very severe malabsorption--clinical observations exemplified by infants with subtotal small intestine resection].

    Science.gov (United States)

    Niessen, K H; Teufel, M

    1984-01-01

    Regenerative and adaptive processes of the gut are apparently analogous to the absorption rate in small bowel diseases. These processes can be enhanced by the prolongation of passage time which, in turn, is influenced by the osmolality of the formula diet. Since infants who have undergone a subtotal bowel resection, like other children with serious diseases of the small bowel, are extraordinarily sensitive to hyperosmolar food, any preparation with special indications should be balanced and rendered hypoosmolar in full caloric concentration. Such formulas may well facilitate food supply to infants and, in case of short bowel syndrome, encourage more pronounced morphologic adaptation.

  10. Outcomes of Total Parathyroidectomy with Autotransplantation versus Subtotal Parathyroidectomy with Routine Addition of Thymectomy to both Groups: Single Center Experience of Secondary Hyperparathyroidism

    Directory of Open Access Journals (Sweden)

    Cem Kaan Parsak

    2014-03-01

    Full Text Available Background: Secondary hyperparathyroidism is a common acquired disorder seen in chronic renal failure. It may result in potentially serious complications including metabolic bone diseases, severe atherosclerosis and undesirable cardiovascular events. Parathyroidectomy is required in about 20% of patients after 3-10 years of dialysis and in up to 40% after 20 years. Aims: The aim of the current study was to evaluate the short-term and long-term outcomes of patients with secondary hyperparathyroidism who had undergone total parathyroidectomy with autotransplantation and thymectomy or subtotal parathyroidectomy with thymectomy by the same surgical team during the study period. Study Design: Retrospective comparative study. Methods: Clinical data of 50 patients who underwent parathyroid surgery for secondary hyperparathyroidism between 2003 and 2011 were reviewed retrospectively. Patients were divided into two subgroups of total parathyroidectomy with autotransplantation or subtotal parathyroidectomy. Thymectomy was routinely performed for both groups. Short term outcome parameters included intact parathyroid hormone, ionized calcium and alkaline phosphatase levels. Bone pain, bone fractures, persistent or recurrent disease were included in long term outcome parameters. Results: The mean duration of dialysis was eight years. The mean ionized calcium levels dropped significantly in the total parathyroidectomy with autotransplantation group (p=0.016. No serious postoperative complications were observed. Postoperative intravenous calcium supplementation was required in four patients in the total parathyroidectomy with autotransplantation group (total PTX+AT and in three patients in the subtotal parathyroidectomy group (subtotal PTX. Postoperatively, all patients received oral calcium carbonate and calcitriol. The length of average hospital stay was 5 (3-10 days. Including nine patients who underwent successful renal transplantation pre-operative bone

  11. Long-term follow-up results of 131I treatment of recurrent hyperthyroidism previously treated by subtotal thyroidectomy

    International Nuclear Information System (INIS)

    Bal, C.S.; Padhy, A.K.; Nair, P.G.

    1998-01-01

    Full text: In patients with recurrent hyperthyroidism following previous subtotal thyroidectomy for Graves' disease or toxic MNG, radioiodine therapy is often recommended. However, our knowledge of the long-term effect of 131 I in this subset of patient is limited. 47 patients presented with post surgery recurrence at thyroid clinic of Nuclear Medicine Department from 1972 to 1996. Mean age of patients at presentation was 43 years (range 23-67 years), 10 were males and 28 had Graves' and rest toxic-MNG. Time of recurrence following surgery varied widely from 6 months to 32 years, 21% recurrent within a year and 75% before tenth year. However, 15% recurred beyond 20 years. 11 patients (23.4%) were aged more than 50 years at the time of recurrence. 34 patients (72%) needed single dose of 131 I (mean dose 288 MBq and range 107 - 740 MBq) and remaining 13 patients multiple doses of 131 I, to be free of thyrotoxicosis (7 patients: 2 doses, 3 patients: 3 doses, 2 patients: 4 doses and the last one 5 doses). 38 patients required ≤370 MBq for this purpose. One individual needed the maximum which was 1480 MBq in divided doses to be euthyroid. The maximum duration of follow-up was 26 years with mean follow up of 10 years. 5 patients were lost to follow-up after their 131 I therapy. The end point considered was confirmed hypothyroidism or euthyroidism in the last visit. 26 patients (62%) were euthyroid and 16 (38%) were hypothyroid after 10 years of mean follow-up period. However, hypothyroidism at the end of one year was in eleven patients (26%). Comparing age, sex, type of gland, time of 131 I treatment and RAIU matched non-operated thyrotoxic patients revealed hypothyroidism rate at first year was 9% and cumulative hypothyroidism after 9.8 years of follow-up (ranging 1-26 years) 36%. This study reveals 15% of patients recur even after 20 years, indicating life-long follow-up after thyroidectomy. The 131 I treatment in these patients shows high initial hypothyroidism rate

  12. Characterization of the early proliferative response of the rodent bladder to subtotal cystectomy: a unique model of mammalian organ regeneration.

    Directory of Open Access Journals (Sweden)

    Charles C Peyton

    Full Text Available Subtotal cystectomy (STC; surgical removal of ∼75% of the rat urinary bladder elicits a robust proliferative response resulting in complete structural and functional bladder regeneration within 8-weeks. The goal of these studies was to characterize the early cellular response that mediates this regenerative phenomenon, which is unique among mammalian organ systems. STC was performed on eighteen 12-week-old female Fischer F344 rats. At 1, 3, 5 and 7-days post-STC, the bladder was harvested 2-hours after intraperitoneal injection of bromodeoxyuridine (BrdU. Fluorescent BrdU labeling was quantified in cells within the urothelium, lamina propria (LP, muscularis propria (MP and serosa. Cell location was confirmed with fluorescently co-labeled cytokeratin, vimentin or smooth muscle actin (SMA, to identify urothelial, interstitial and smooth muscle cells, respectively. Expression of sonic hedgehog (Shh, Gli-1 and bone morphogenic factor-4 (BMP-4 were evaluated with immunochemistry. Three non-operated rats injected with BrdU served as controls. Less than 1% of cells in the bladder wall were labeled with BrdU in control bladders, but this percentage significantly increased by 5-8-fold at all time points post-STC. The spatiotemporal characteristics of the proliferative response were defined by a significantly higher percentage of BrdU-labeled cells within the urothelium at 1-day than in the MP and LP. A time-dependent shift at 3 and 5-days post-STC revealed significantly fewer BrdU-labeled cells in the MP than LP or urothelium. By 7-days the percentage of BrdU-labeled cells was similar among urothelium, LP and MP. STC also caused an increase in immunostaining for Shh, Gli-1 and BMP-4. In summary, the early stages of functional bladder regeneration are characterized by time-dependent changes in the location of the proliferating cell population, and expression of several evolutionarily conserved developmental signaling proteins. This report extends

  13. The image of urachus adenocarcinoma on Doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Oyar, Orhan E-mail: o_oyar@hotmail.com; Yesildag, Ahmet; Gulsoy, Ufuk Kemal; Perk, Hakki

    2002-10-01

    Malignant urachal lesions are exceedingly rare and occur predominantly in adult life. In this case report, an adult patient with urachal carcinoma is presented with abdominal plain film, intravenous urography, gray-scale ultrasonography (US), Doppler US, and computed tomography (CT). Doppler US successfully showed the neovascularity with low resistive index value in the urachus tumor. We believe that Doppler US examination is helpful in the differential diagnosis of urachal carcinoma.

  14. Is ultrasonography essential before surgery in eyes with advanced cataracts?

    Directory of Open Access Journals (Sweden)

    Salman Amjad

    2006-01-01

    Full Text Available Background: Ultrasonography is an important tool for evaluating the posterior segment in eyes with opaque media. Aim: To study the incidence of posterior segment pathology in eyes with advanced cataract and to see whether certain features could be used as predictors for an abnormal posterior segment on ultrasound. Setting: Tertiary care hospital in South India. Methods and Materials: In this prospective study conducted over a 6-month period, all eyes with dense cataracts precluding visualization of fundus underwent assessment with ultrasound. Presence of certain patient and ocular "risk" factors believed to be associated with a higher incidence of abnormal posterior segment on ultrasound were looked for and the odds ratio (OR for posterior segment pathology in these eyes was calculated. Results: Of the 418 eyes assessed, 36 eyes (8.6% had evidence of posterior segment pathology on ultrasound. Retinal detachment (17 eyes; 4.1% was the most frequent abnormality detected. Among patient features, diabetes mellitus (OR= 4.9, P=0.003 and age below 50 years (OR= 15.4, P=0.001 were associated with a high incidence of abnormal ultrasound scans. In ocular features, posterior synechiae (OR= 20.2, P=0.000, iris coloboma (OR= 34.6, P=0.000, inaccurate projection of rays (OR= 15.1, P=0.002, elevated intraocular pressure (OR= 15.1, P=0.004, and keratic precipitates (OR= 22.4, P=0.004 were associated with high incidence of posterior segment pathology. Only four eyes (1.5% without these features had abnormal posterior segment on ultrasonography. Conclusions: Certain patient and ocular features are indicative of a high risk for posterior segment pathology and such patients should be evaluated by ultrasonography prior to cataract surgery. In the absence of these risk factors, the likelihood of detecting abnormalities on preoperative ultrasonography in eyes with advanced cataracts is miniscule.

  15. Comparison of ultrasonography and radiography in diagnosis of rib fractures

    OpenAIRE

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-01-01

    Purpose: Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. Methods: In this cross-s...

  16. Pictorial essay: B-scan ultrasonography in ocular abnormalities

    International Nuclear Information System (INIS)

    Aironi, VD; Gandage, SG

    2009-01-01

    B-scan ultrasonography (USG) is a simple, noninvasive tool for diagnosing lesions of the posterior segment of the eyeball. Common conditions such as cataract, vitreous degeneration, retinal detachment, ocular trauma, choroidal melanoma, and retinoblastoma can be accurately evaluated with this modality. B-scan USG is cost-effective, which is an important consideration in the rural setting. In addition, it is noninvasive and easily available and the results are reproducible

  17. Ultrasonography of the omasum in 30 Saanen goats

    Directory of Open Access Journals (Sweden)

    Jacquat Désirée

    2011-02-01

    Full Text Available Abstract Background Primary diseases of the omasum are uncommon in goats, although the omasum may be involved in various gastrointestinal disorders. Examination of the caprine omasum via ultrasonography requires a good understanding of the normal appearance of the organ. However, in contrast to cattle, there is a lack of reference information on this topic in goats. Thus, the goal of the present study was to describe the results of ultrasonography of the omasum in 30 healthy Saanen goats. Results Ultrasonography was carried out in standing, non-sedated goats using a 5.0 MHz linear transducer. The location and size of the omasum, thickness of the omasal wall and visualisation of the abomasal laminae, contents and contractions were assessed. The omasum was visible from the 9th intercostal space (ICS in all the goats, and from the 8th and 10th ICSs in 29 and 24 goats, respectively. The omasum was seen medial to the liver, but only the omasal wall closest to the transducer was visible. The dorsal omasal limit formed a dorsally convex curve running from cranioventral to caudodorsal and was furthest from the dorsal midline in the 6th ICS. The ventral omasal limit formed a ventrally convex curve. The size of the omasum was largest (10.2 ± 3.1 cm in the 9th ICS and decreased cranially and caudally from this position. Active omasal motility was recorded in 20 goats with 0.3 to 2.0 contractions per minute. Conclusions The findings of this study provide reference ranges for the interpretation of the location and size of the omasum in goats with suspected omasal abnormalities. Ultrasonography is an ideal diagnostic tool for evaluation of the omasum, which is not accessible to conventional examination techniques, such as inspection, palpation, percussion and auscultation.

  18. Urinary tract infection in children: Role of ultrasonography

    International Nuclear Information System (INIS)

    Lee, Hye Won; Lee, Sun Wha; Ko, Young Tae; Lim, Joo Won

    1994-01-01

    To evaluate diagnostic usefulness of ultrasonography(US) in pediatric patient with urinary tract infection. Fifty-five children with urinary tract infection underwent renal ultrasonography and voiding cystourethrography(VCUG). The imaging findings were analyzed retrospectively. Renal sonograms were normal in 34 of 55 children(62%). Five of 34 patients with normal sonogram had vesicoureteral reflux of grade I and III on VCUG. Renal sonograms were abnormal in 21 of 55 children(38%). Sonographic findings included hydronephrosis, hyperechoic kidney, nephromegaly, altrophic kidney, renal abscess, and duplex ureter. Eleven of 21 patient with abnormal sonogram had vesicoureteral reflux of grade I to IV on VCUG. Ultrasonography is an useful and reliable initial screening examination in the investigation of children with UTI. Unfortunately US is neither sufficiently sensitive nor specific for detecting VUR. VCUG provides confirmative and valuable information about vesicoureteral reflux, and VCUG should be considered as a next modality for UTI. The combined use of sonography and VCUG provides more valuable information in urinary tract infection

  19. Ultrasonography of the equine shoulder: technique and normal appearance.

    Science.gov (United States)

    Tnibar, M A; Auer, J A; Bakkali, S

    1999-01-01

    This study was intended to document normal ultrasonographic appearance of the equine shoulder and anatomic landmarks useful in clinical imaging. Both forelimbs of five equine cadavers and both forelimbs of six live adult horses were used. To facilitate understanding of the images, a zoning system assigned to the biceps brachii and to the infraspinatus tendon was developed. Ultrasonography was performed with a real-time B-mode semiportable sector scanner using 7.5- and 5-MHz transducers. On one cadaver limb, magnetic resonance imaging (MRI) was performed using a system at 1.5 Tesla, T1-weighted spin-echo sequence. Ultrasonography images were compared to frozen specimens and MRI images to correlate the ultrasonographic findings to the gross anatomy of the shoulder. Ultrasonography allowed easy evaluation of the biceps brachii and the infraspinatus tendon and their bursae, the supraspinatus muscle and tendons, the superficial muscles of the shoulder, and the underlying humerus and scapula. Only the lateral and, partially, the caudal aspects of the humeral head could be visualized with ultrasound. Ultrasonographic appearance, orientation, and anatomic relationships of these structures are described. Ultrasonographic findings correlated well with MRI images and with gross anatomy in the cadavers' limbs.

  20. Evaluation of arterial embolization in treating hyperthyroidism by colour ultrasonography

    International Nuclear Information System (INIS)

    Sun Xiuying; Yang Jijin; Chen Ningning; Gu Limin; Wang Ying; Chen Jianquan

    2003-01-01

    Objective: To assess the effect of arterial embolization in treating hyperthyroidism by colour ultrasonography. Methods: Forty two cases of hyperthyroidism were treated with thyroid-arteries embolization. A few days before and 1, 3, 6 months after embolization, the echograms of thyroids were observed including the volumes of thyroids and the internal diameters of thyroid-arteries were measured with colour ultrasonography respectively. The Vs, Vd, Vm, PI, RI were measured with the Doppler and the quantities of blood flow were calculated. The relationships of changes for all these parameters and T 3 , T 4 and TSH were analysed. Results: Before artery embolization all thyroids were enlarged with diffusely homogenous or heterogenous low-echoes and nodules in some patients accompanied by widening of the thyroid arteries and their branches full of blood supply. The volume of thyroids decreased after artery embolization. 1-3 months later the echo of thyroids enhanced and got coarse with decrease of the thyroid vasculature and narrowing of vessel calibers except a few star- or stop-like blood streams were sometimes seen within the thyroids and no blood flow signals found in some cases. 3-6 months after embolization, the echo of thyroids decreased gradually or unevenly distributed. All the parameters of blood flow before and after the treatment showed statistically significant differences (P < 0.05). Conclusions: Embolization of thyroid arteries is a relatively new and effective technique in treating hyperthyroidism. Colour Doppler ultrasonography plays an important role for correct diagnosis and prognostication

  1. Peritoneal inclusion cysts: Changes on follow-up ultrasonography

    International Nuclear Information System (INIS)

    Kim, Jung Sik; Lee, Jin Hee; Lee, Hee Jung; Lee, Sung Moon; Woo, Seong Ku

    2003-01-01

    To evaluate the volume change of peritoneal inclusion cysts on the follow-up ultrasonography (US). From March 1995 to May 1999, thirty seven women with ultrasonographically diagnosed peritoneal inclusion cysts were included in this study. Six patients underwent surgery for several reasons. Follow-up ultrasonography was performed 70-456 days (mean=191 days) after initial US examination in 12 of the remaining 31 patient with no further treatment. US was performed with a 3.5 or 4 MHz transabdominal probe in all 18 patients who underwent either surgery or follow-up US, and additional tranvaginal US examination using a 5-7 MHz probe in 15 of 18 patients. The volume change of the cysts was recorded for each US examination. Three cysts (25%) (volume=170 cm 3 , 61 cm 3 , and 38 cm 3 , respectively) were completely resolved on the follow-up US while the other nine cysts showed a decreased volume in seven patients (58%) and increased volume in two patients (17%). Spontaneous regression of peritoneal inclusion cysts is more common than it is believed to be, and ultrasonography may be a useful follow-up examination for peritoneal inclusion cysts.

  2. Ultrasonography in the evaluation of tongue and mouth pathology

    International Nuclear Information System (INIS)

    Lee, Chan Wha; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Lee, Jong Tae; Hong, Won Pyo; Park, Hyung Sik

    1991-01-01

    The evaluation of the tongue and mouth floor using the CT scan can be limited due to dental artifacts. Because the therapeutic plan depends on the nature and the cancer staging of lesions, it is essential to obtain accurate evaluation of lesions. In this study are explored the of Ultrasonography for the evaluation of tongue and mouth floor pathology. We have obtained ultrasonograms in 20 patients who had benign and malignant lesions in the tongue and mouth floor. Comparative analysis was made on 15 patients who underwent both CT and ultrasonography. We used the bimanual compression technique and the phonation technique during real-time scanning. Out of 15 cases, six had tongue cancer, and seven of them had cancer of the mouth floor. The other cases included a ranula, a dermoid cyst, a Ludwig's angina, and abscess of salivary gland, and one care with stones of the submandibular gland. All the benign and malignant masses appeared hypoechoic. Even though the lesions of tongue and mouth floor could not be evaluated by CT scan due to dental artifacts and extremely small size in 5 cases, ultrasonogram using the bimanual compression technique demonstrated good localization of the lesion, and also was greatly helpful in visualizing the invasion of the surrounding structures. Ultrasonography of the tongue and mouth floor proved to be superior to the CT scan not only in delineating the size and extent of the primary lesion, but also in visualizing invasion of surrounding structures

  3. MRI versus ultrasonography to assess meniscal abnormalities in acute knees.

    Science.gov (United States)

    Cook, James L; Cook, Cristi R; Stannard, James P; Vaughn, Gavin; Wilson, Nichole; Roller, Brandon L; Stoker, Aaron M; Jayabalan, Prakash; Hdeib, Moses; Kuroki, Keiichi

    2014-08-01

    While magnetic resonance imaging (MRI) is often considered the "gold standard" diagnostic imaging modality for detection of meniscal abnormalities, it is associated with misdiagnosis in as high as 47% of cases, is costly, and is not readily available to a large number of patients. Ultrasonographic examination of the knee has been reported to be an effective diagnostic tool for this purpose with the potential to overcome many of the shortcomings of MRI. The purpose of this study is to determine the clinical usefulness of ultrasonography for diagnosis of meniscal pathology in patients with acute knee pain and compare its diagnostic accuracy to MRI in a clinical setting. With Institutional Review Board approval, patients (n = 71) with acute knee pain were prospectively enrolled with informed consent. Preoperative MRI (1.5 T) was performed on each affected knee using the hospital's standard equipment and protocols and read by faculty radiologists trained in musculoskeletal MRI. Ultrasonographic assessments of each affected knee were performed by one of two faculty members trained in musculoskeletal ultrasonography using a 10 to 14 MHz linear transducer. Arthroscopic evaluation of affected knees was performed by one of three faculty orthopedic surgeons to assess and record all joint pathology, which served as the reference standard for determining presence, type, and severity of meniscal pathology. All evaluators for each diagnostic modality were blinded to all other data. Data were collected and compared by a separate investigator to determine sensitivity (Sn), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), correct classification rate (CCR), likelihood ratios (LR[+] and LR[-]), and odds ratios. Preoperative ultrasonographic assessment of meniscal pathology was associated with Sn = 91.2%, Sp = 84.2%, PPV = 94.5%, NPV = 76.2%, CCR = 89.5%, LR(+) = 5.78, and LR(-) = 0.10. Preoperative MRI assessment of

  4. [Low grade renal trauma (Part II): diagnostic validity of ultrasonography].

    Science.gov (United States)

    Grill, R; Báca, V; Otcenásek, M; Zátura, F

    2010-04-01

    The aim of the study was to verify whether ultrasonography can be considered a reliable method for the diagnosis of low-grade renal trauma. The group investigated included patients with grade I or grade II blunt renal trauma, as classified by the AAST grading system, in whom ultrasonography alone or in conjunction with computed tomography was used as a primary diagnostic method. B-mode ultrasound with a transabdominal probe working at frequencies of 2.5 to 5.0 MHz was used. Every finding of post-traumatic changes in the renal tissues, i.e., post-contusion hypotonic infiltration of the renal parenchyma or subcapsular haematoma, was included. The results were statistically evaluated by the Chi-square test with the level of significance set at 5%, using Epi Info Version 6 CZ software. The group comprised 112 patients (43 women, 69 men) aged between 17 and 82 years (average, 38 years). It was possible to diagnose grade I or grade II renal injury by ultrasonography in only 60 (54%) of them. The statistical significance of ultrasonography as the only imaging method for the diagnosis of low-grade renal injury was not confirmed (p=0.543) Low-grade renal trauma is a problem from the diagnostic point of view. It usually does not require revision surgery and, if found during repeat surgery for more serious injury of another organ, it usually does not receive attention. Therefore, the macroscopic presentation of grade I and grade II renal injury is poorly understood, nor are their microscopic findings known, because during revision surgery these the traumatised kidneys are not usually removed and their injuries at autopsy on the patients who died of multiple trauma are not recorded either. The results of this study demonstrated that the validity of ultrasonography for the diagnosis of low-grade renal injury is not significant, because this examination can reveal only some of the renal injuries such as perirenal haematoma. An injury to the renal parenchyma is also indicated by

  5. Ultrasonography evaluation during the weaning process: the heart, the diaphragm, the pleura and the lung.

    Science.gov (United States)

    Mayo, P; Volpicelli, G; Lerolle, N; Schreiber, A; Doelken, P; Vieillard-Baron, A

    2016-07-01

    On a regular basis, the intensivist encounters the patient who is difficult to wean from mechanical ventilatory support. The causes for failure to wean from mechanical ventilatory support are often multifactorial and involve a complex interplay between cardiac and pulmonary dysfunction. A potential application of point of care ultrasonography relates to its utility in the process of weaning the patient from mechanical ventilatory support. This article reviews some applications of ultrasonography that may be relevant to the process of weaning from mechanical ventilatory support. The authors have divided these applications of ultrasonography into four separate categories: the assessment of cardiac, diaphragmatic, and lung function; and the identification of pleural effusion; which can all be evaluated with ultrasonography during a dynamic process in which the intensivist is uniquely positioned to use ultrasonography at the point of care. Ultrasonography may have useful application during the weaning process from mechanical ventilatory support.

  6. The role of contrast-enhanced ultrasonography in image-guided liver ablations

    International Nuclear Information System (INIS)

    Pescatori, Lorenzo Carlo; Sconfienza, Luca Maria; Mauri, Giovanni

    2016-01-01

    We read with great interest the paper by Kim et al. entitled “Local ablation therapy with contrast enhanced ultrasonography for hepatocellular carcinoma: a practical review,” recently published in Ultrasonography. We think that contrast-enhanced ultrasonography (CEUS), together with the development of reliable navigation systems, is likely to represent one of the most important advances in image-guided ablations in recent years. Thus, we offer some considerations on the topic

  7. Prenatal diagnosis of Beckwith-Wiedemann syndrome by two- and three-dimensional ultrasonography

    Directory of Open Access Journals (Sweden)

    Edward Araujo Junior

    2013-12-01

    Full Text Available Beckwith-Wiedemann syndrome is a genetic syndrome characterized by macroglossia, omphalocele, fetal gigantism and neonatal hypoglycemia. The authors report a case of Beckwith-Wiedemann syndrome diagnosed in a 32-year-old primigravida in whom two-dimensional ultrasonography revealed the presence of abdominal wall cyst, macroglossia and polycystic kidneys. Three-dimensional ultrasonography in rendering mode was of great importance to confirm the previous two-dimensional ultrasonography findings.

  8. Evaluation of abdominal palpation, radiography and ultrasonography for pregenancy diagnosis in bitches

    International Nuclear Information System (INIS)

    Arunmozhi, N.; Naidu, K.V.; Sreenu, M.; Rao, A.S.

    2005-01-01

    Abdominal palpation, radiography and ultrasonography were compared for pregnancy diagnosis in bitches. The earliest correct diagnosis of pregnancy was made by 22 and 21 days with abdominal palpation and ultrasonography respectively, while radiography led to more accurate diagnosis in last trimester of pregnancy. All the methods revealed 100 per cent accuracy in last trimester where as ultrasonography gave constant results from day 21 up to termination of pregnancy followed by abdominal palpation

  9. Avaliação da função fagocitária em remanescentes de esplenectomia subtotal e auto-implante esplênico autógeno

    OpenAIRE

    Petroianu,Andy

    2003-01-01

    Para diminuir os efeitos adversos da esplenectomia total, abordagens conservadoras devem ser tentadas, quando for possível. Esplenectomia subtotal e auto-implantes esplênicos são boas alternativas nessa situação. O objetivo do presente estudo foi comparar as funções fagocitárias do pólo superior remanescente de esplenectomia subtotal e de tecido esplênico implantado no omento maior. Esta investigação foi conduzida em 35 ratos Holtzman adultos de ambos os sexos. Todos os animais foram submetid...

  10. Comparison of the results of abdominal ultrasonography and exploratory laparotomy in the dog and cat.

    Science.gov (United States)

    Pastore, Gina E; Lamb, Christopher R; Lipscomb, Victoria

    2007-01-01

    Results of preoperative ultrasonography and exploratory laparotomy were reviewed retrospectively in a series of 100 small animals to assess the agreement between ultrasonographic and surgical findings and to identify abdominal lesions likely to be missed by ultrasonography. Good agreement occurred between ultrasound reports and surgical reports in 64% of the animals, which supported the use of ultrasonography in potential surgical candidates. A major discrepancy was observed between the ultrasound report and surgical findings in 25% of the animals. Of the various types of pathology encountered in the study, gastrointestinal ulceration or perforation was the most likely lesion to be missed by ultrasonography.

  11. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young [Dept. of Radiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  12. Comparative study of scintigraphy, ultrasonography and computed tomography in the evaluation of liver tumours

    International Nuclear Information System (INIS)

    Tohyama, Junko; Ishigaki, Takeo; Ishikawa, Tsutomu

    1982-01-01

    A comparative study of scintigraphy, ultrasonography and computed tomography in 67 proven patients with clinically suspected liver tumours was reported. Scintigraphy was superior in sensitivity to ultrasonography and computed tomography. However, in specificity, scintigraphy was inferior to other two. Diagnostic efficacy of ultrasonography and computed tomography in detecting focal masses of the liver was not greatly different, and simultaneous interpretation of ultrasonogram and computed tomogram was more helpful than independent interpretation. So they were thought to be complementary. In conclusion, scintigraphy was thought to be the initial procedure in the diagnostic approach for focal liver masses and ultrasonography was second procedure because of no radiation hazards. And computed tomography should follow then. (author)

  13. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Directory of Open Access Journals (Sweden)

    Ji Young Hwang

    2017-04-01

    Full Text Available Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  14. Ultrasonography survey and thyroid cancer in the Fukushima Prefecture

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, Peter; Kaiser, Jan Christian; Ulanovsky, Alexander [Helmholtz Zentrum Muenchen-German Research Center for Environmental Health, Department of Radiation Sciences, Institute of Radiation Protection, Neuherberg (Germany)

    2014-05-15

    Thyroid cancer is one of the major health concerns after the accident in the Fukushima Dai-ichi nuclear power station (NPS). Currently, ultrasonography surveys are being performed for persons residing in the Fukushima Prefecture at the time of the accident with an age of up to 18 years. Here, the expected thyroid cancer prevalence in the Fukushima Prefecture is assessed based on an ultrasonography survey of Ukrainians, who were exposed at an age of up to 18 years to {sup 131}I released during the Chernobyl NPS accident, and on differences in equipment and study protocol in the two surveys. Radiation risk of thyroid cancer incidence among survivors of the atomic bombings of Hiroshima and Nagasaki and preliminary estimates of thyroid dose due to the Fukushima accident were used for the prediction of baseline and radiation-related thyroid cancer risks. We estimate a prevalence of thyroid cancer of 0.027 % (95 % CI 0.010 %; 0.050 %) for the first screening campaign in the Fukushima Prefecture. Compared with the incidence rate in Japan in 2007, the ultrasonography survey is predicted to increase baseline thyroid cancer incidence by a factor of 7.4 (95 % CI 0.95; 17.3). Under the condition of continued screening, thyroid cancer during the first fifty years after the accident is predicted to be detected for about 2 % of the screened population. The prediction of radiation-related thyroid cancer in the most exposed fraction (a few ten thousand persons) of the screened population of the Fukushima Prefecture has a large uncertainty with the best estimates of the average risk of 0.1-0.3 %, depending on average dose. (orig.)

  15. [Technique of abdominal ultrasonography in newborn foals and normal findings].

    Science.gov (United States)

    Behn, C; Bostedt, H

    2000-09-01

    Under field conditions, the diagnosis of foal's diseases relies almost exclusively on the physical examination. As the signs of illness in the equine neonate are frequently vage and non-localizing, the diagnosis of diseases may be problematic. This often causes misinterpretations and leads to ineffective prophylaxis and treatment. The purpose of this study was to evaluate the usefulness of diagnostic ultrasonography of the foal's abdomen under field conditions to provide an optimized technique and to describe the normal findings. Diagnostic ultrasonography of the abdomen was performed after obtaining clinical history and passing the physical examination of 25 foals without signs of abdominal problems. The foals were scanned in a stable box, being restrained by three persons in semi-lateral recumbency. Usually, sedation was not necessary. The ventral abdominal wall was clipped, a generous amount of ultrasound coupling gel was applied and massaged on the skin surface. The ultrasonographic examination was carried out using a portable sector scanner ("Microimager 2000", Ausonics) with 5.0 and 7.5-MHz transducers or a combined 5.0 and 7.5-MHz transrectal linear-array scanner ("450 Enhanced", Pie Medical). Employing the 5.0-MHz sector scanner first, the abdomen was explored from caudal to cranial in left and right semi-lateral recumbency. The 7.5-MHz scanner was used to attain higher resolution of certain structures. The sector scanner turned out to be suitable under field conditions and adequate to examine the abdominal organs. The transrectal linear-array scanner also provided the most important informations, although it was difficult to maintain a good contact area of the scan head. By ultrasonography it was possible to identify the urinary bladder, kidneys, spleen, liver and part of the gastrointestinal tract. Thus, application of ultrasound could successfully be performed on newborn foals under field conditions.

  16. Stomach: ultrasonography evaluation and post mortem inspection in adult horses

    Directory of Open Access Journals (Sweden)

    Cristiano Chaves Pessoa da Veiga

    2014-06-01

    Full Text Available ABSTRACT. Veiga C.C.P., Cascon C.M., Souza B.G., Braga L.S.M., Souza V.C., Ferreira A.M.R. & Leite J.S. [Stomach: ultrasonography evaluation and post mortem inspection in adult horses.] Avaliação ultrassonográfica e anatomopatológica macroscópica do estômago de equinos destinados ao abate comercial. Revista Brasileira de Medicina Veterinária, 36(2:125-130, 2014. Instituto de Veterinária, Universidade Federal Rural do Rio de Janeiro, BR 465, km 7, Seropédica, 23890-000, RJ, Brasil. E-mail: radiovet@ufrrj.br The equine gastric ulcer syndrome (EGUS includes all symptomatic or asymptomatic cases of erosions, ulcers, gastritis, gastric emptying disorders, duodenitis, duodenal ulcers and complications of these disorders. Occupies a prominent place in the equine clinic where you can go for the death of the animal. Ultrasonography of the stomach is indicated when the animals showed clinical signs of gastric disease. The aim of this study was to describe the sonographic evaluation and macroscopic pathological findings of the stomach of adult horses intended for commercial slaughter. To this 39 intended for commercial slaughter horses were evaluated. Sonographic evaluation before slaughter transabdominal via the left side of abdomen for evaluation of the stomach was performed. After the slaughter of these animals their stomachs were collected, evaluated and photographed. The study concluded that ultrasonography identified the stomach in all animals evaluated, but did not allow a careful evaluation of the entire length of the viscera, especially the aglandular region and pleated border. All animals evaluated had injury to the gastric mucosa in different degrees. In animals evaluated, the stomach region was most affected by injuries glandular region, although the most severe lesions have been found in the ruffled border adjacent to aglandular region.

  17. High-resolution ultrasonography in assessing temporomandibular joint disc position.

    Science.gov (United States)

    Talmaceanu, Daniel; Lenghel, Lavinia Manuela; Bolog, Nicolae; Popa Stanila, Roxana; Buduru, Smaranda; Leucuta, Daniel Corneliu; Rotar, Horatiu; Baciut, Mihaela; Baciut, Grigore

    2018-02-04

    The purpose of this study was to determine the diagnostic value of high-resolution ultrasonography (US) in temporomandibular joint (TMJ) disc displacements. A number of 74 patients (148 TMJs) with signs and symptoms of TMJ disorders, according to the Research Diagnostic Criteria for Temporomandibular Disorders, were included in this study. All patients received US and magnetic resonance imaging (MRI) of both TMJs 1 to 5 days after the clinical examination. MRI examinations were performed using 1.5 T MRI equipment (Siemens Avanto, Siemens, Erlangen). Ultrasonographic examination was performed on a Hitachi EUB 8500 (Hitachi Medical Corp., Tokyo, Japan) scanner with L 54 M6.5-13 MHz linear transducer. MRI depicted 68 (45.95%) normal joints, 47 (31.76%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 34 (22.97%) with degenerative changes. US detected 78 (52.7%) normal joints, 37 (25%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 21 (14.19%) with degenerative changes. Compared to MRI, US showed a sensitivity of 93.1%, specificity of 87.88%, accuracy of 90.32%, a positive predictive value of 87.1% and a negative predictive value of 93.55% for overall diagnosis of disc displacement. The Youden index was 0.81. Based on our results, high-resolution ultrasonography showed high sensitivity, specificity and accuracy in the diagnosis of TMJ disc displacement. It could be a valuable imaging technique in assessing TMJ disc position. The diagnostic value of high-resolution ultrasonography depends strictly on the examiner's skills and on the equipment used.

  18. Diagnostic accuracy of the ultrasonography in complicated pregnancy

    International Nuclear Information System (INIS)

    Cha, Kyung Soo; Kim, Kun Sang; Park, Soo Soung

    1983-01-01

    Ultrasonography is an invaluable diagnostic method in Obstetrics. It provides safe, speedy and repeatable way to obtain image of normal and abnormal pregnancy. The ultrasonograms of 167 patients with suspicion of complicated pregnancy were analyzed. The results were as follows. 1. 86 patients showed normal ultrasonogram(50.9%). 100% in intrauterine fetal death and gross fetal anomaly, 100% in abnormal fetal position and number, 95% in pregnancy with pelvic mass, 83% in ectopic pregnancy, 81% in abortion, 78% in molar pregnancy, 74% in plancenta previa. 3. Ultrasonic diagnosis of abrupto placenta was difficult. 4. Diagnostic accuracy was 80% in bicornuate uterus and double vagina

  19. Clinical application of endoscopic ultrasonography for esophageal achalasia.

    Science.gov (United States)

    Minami, Hitomi; Inoue, Haruhiro; Isomoto, Hajime; Urabe, Shigetoshi; Nakao, Kazuhiko

    2015-04-01

    Endoscopic ultrasonography (EUS) has been widely used for evaluating the nature of diseases of various organs. The possibility of applying EUS for esophageal motility diseases has not been well discussed despite its versatility. At present, peroral endoscopic myotomy (POEM) for esophageal achalasia and related diseases has brought new attention to esophageal diseases because POEM provides a more direct approach to the inner structures of the esophageal wall. In the present study, we discuss the clinical utility of EUS in evaluating and treating esophageal motility diseases such as esophageal achalasia and related diseases. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  20. Quadriceps Function and Knee Joint Ultrasonography after ACL Reconstruction.

    Science.gov (United States)

    Pamukoff, Derek N; Montgomery, Melissa M; Moffit, Tyler J; Vakula, Michael N

    2018-02-01

    Individuals with anterior cruciate ligament reconstruction (ACLR) are at greater risk for knee osteoarthritis, partially because of chronic quadriceps dysfunction. Articular cartilage is commonly assessed using magnetic resonance imaging and radiography, but these methods are expensive and lack portability. Ultrasound imaging may provide a cost-effective and portable alternative for imaging the femoral cartilage. The purpose of this study was to compare ultrasonography of the femoral cartilage between the injured and uninjured limbs of individuals with unilateral ACLR, and to examine the association between quadriceps function and ultrasonographic measures of femoral cartilage. Bilateral femoral cartilage thickness and quadriceps function were assessed in 44 individuals with unilateral ACLR. Quadriceps function was assessed using peak isometric strength, and early (RTD100) and late (RTD200) rate of torque development. Cartilage thickness at the medial femoral condyle (P accounting for time since ACLR, quadriceps peak isometric strength was associated with cartilage thickness at the medial femoral condyle (r = 0.35, P = 0.02) and femoral cartilage cross-sectional area (r = 0.28, P = 0.04). RTD100 and RTD200 were not associated with femoral cartilage thickness or cross-sectional area. Individuals with ACLR have thinner cartilage in their injured limb compared with uninjured limb, and cartilage thickness is associated with quadriceps function. These results indicate that ultrasonography may be useful for monitoring cartilage health and osteoarthritis progression after ACLR.

  1. Three-dimensional ultrasonography in the diagnosis of deep endometriosis.

    Science.gov (United States)

    Guerriero, Stefano; Saba, Luca; Ajossa, Silvia; Peddes, Cristina; Angiolucci, Marco; Perniciano, Maura; Melis, Gian Benedetto; Alcázar, Juan Luis

    2014-06-01

    In the use of 'tenderness-guided' transvaginal ultrasound, is the diagnostic accuracy of three-dimensional (3D) ultrasonography better than two-dimensional (2D) ultrasonography in the identification of deep endometriosis? Three-dimensional ultrasonography has a significantly higher diagnostic accuracy in the diagnosis of posterior locations of deep endometriosis without intestinal involvement, such as the uterosacral ligaments, vaginal and rectovaginal endometriosis. The only previous study of the diagnosis of posterior compartment endometriosis reported an poor sensitivity of 3D ultrasonography for uterosacral and sigmoid colon involvement. This diagnostic test study included 202 patients scheduled for surgery because of clinical suspicion of deep pelvic endometriosis and was carried out between January 2009 and September 2012. Modified transvaginal ultrasonography was performed on all of the women by a single examiner. Two locations of deep endometriosis were considered: intestinal involvement and other posterior lesions (including vaginal location, rectovaginal septum and uterosacral ligaments). Once the 2D ultrasonography had been performed, the 3D acquisition was performed and the obtained volume was stored. To avoid the risk of recall bias, the same operator evaluated the 3D volumes 6 months after the last examination using virtual navigation to provide a presumptive diagnosis of the presence and localization of deep endometriosis. In addition, to evaluate the reproducibility of 3D, two operators with different levels of expertise performed a retrospective review of 3D volumes from a random sample of 35 patients, twice, 1 week apart to also assess intraobserver agreement. The diagnostic performance of both tests was expressed as area under the receiver-operating characteristics curve (AUC), sensitivity, specificity, positive and negative predictive values, positive (LR+) and negative (LR-) likelihood ratios, with their respective 95% confidence interval (CI

  2. Ultrasonography for neuraxial blocks: a review of the evidence.

    Science.gov (United States)

    Elgueta, Maria F; Duong, Silvia; Finlayson, Roderick J; Tran, De Q

    2017-05-01

    This narrative review summarizes the evidence derived from randomized controlled trials (RCTs) pertaining to the use of adjunctive ultrasonography (US) for neuraxial blocks. The literature search was conducted using the MEDLINE, EMBASE and PUBMED databases. For the MEDLINE and EMBASE searches, the MESH terms "ultrasonography" and key word "ultrasound" were queried; using the operator "and", they were combined with the MESH terms "neuraxial block," "epidural anesthesia," "epidural analgesia," "spinal anesthesia," "spinal analgesia," "intrathecal anesthesia," "intrathecal analgesia," "caudal anesthesia," and "caudal analgesia." For the PUBMED search, the search terms "ultrasound neuraxial," "ultrasound intrathecal," "ultrasound epidural" (limited to clinical trials), "ultrasound spinal" (limited to clinical trials), and "ultrasound caudal" (limited to clinical trials) were queried. Seventeen RCTs were retained for analysis. Compared to conventional palpation of landmarks, US assistance (i.e., preprocedural scanning) results in fewer needle passes/insertions and skin punctures for neuraxial blocks in obstetrical and surgical patients. These benefits seem most pronounced when expert operators carry out the sonographic exams and for patients displaying difficult spinal anatomy. Preliminary findings also suggest that US provides similar pain relief and functional improvement to fluoroscopy for epidural/caudal steroid injection in patients afflicted with chronic spinal pain. Although one trial demonstrated shorter needling time with US guidance (i.e., real-time scanning of needle advancement) compared to US assistance, these findings require further validation. Published reports of RCTs provide evidence to formulate limited recommendations regarding the use of adjunctive US for neuraxial blocks. Further well-designed RCTs are warranted.

  3. Intraoperative ultrasonography of liver, bile ducts and pancreas

    Directory of Open Access Journals (Sweden)

    Luciana Mendes de Oliveira Cerri

    Full Text Available The use of intraoperative ultrasonography (IOUS to evaluate liver, bile ducts and pancreatic disease, as compared to the results of preoperative ultrasonography and CT, is discussed. Forty-two patients who underwent abdominal surgery for suspected hepatobiliary and/or pancreatic disease were studied. The intraoperative study was carried out with a portable apparatus (Aloka 500, Japan, using 5.0 MHz and 7.5 MHz linear sterile transducers. The main indications for IOUS were the search for and/or evaluation of primary hepatic masses,hepatic abscesses or metastases, obstructive jaundice, or neuroendocrine tumors. In 15 cases (38.5 percent from the hepatobiliary group and in 7 cases (58.3 percent from the pancreatic group, a difference between preoperative and intraoperative findings was observed. The main difference was observed in relation to the number and size of hepatic and pancreatic lesions. The relationship between the lesions and the vascular structures was evaluated through IOUS. The method was also used to guide surgical procedures such as biopsies, the alcoholization of nodules, and the drainage of abscesses. IOUS plays an important role in detecting small hepatic and pancreatic nodules, in the assessment of anatomical relationships between the lesions and the vascular structures, and in the performance of interventionist procedures.

  4. Validation of equations for pleural effusion volume estimation by ultrasonography.

    Science.gov (United States)

    Hassan, Maged; Rizk, Rana; Essam, Hatem; Abouelnour, Ahmed

    2017-12-01

    To validate the accuracy of previously published equations that estimate pleural effusion volume using ultrasonography. Only equations using simple measurements were tested. Three measurements were taken at the posterior axillary line for each case with effusion: lateral height of effusion ( H ), distance between collapsed lung and chest wall ( C ) and distance between lung and diaphragm ( D ). Cases whose effusion was aspirated to dryness were included and drained volume was recorded. Intra-class correlation coefficient (ICC) was used to determine the predictive accuracy of five equations against the actual volume of aspirated effusion. 46 cases with effusion were included. The most accurate equation in predicting effusion volume was ( H  +  D ) × 70 (ICC 0.83). The simplest and yet accurate equation was H  × 100 (ICC 0.79). Pleural effusion height measured by ultrasonography gives a reasonable estimate of effusion volume. Incorporating distance between lung base and diaphragm into estimation improves accuracy from 79% with the first method to 83% with the latter.

  5. Screening ultrasonography of 2,204 patients with blunt abdominal trauma in the Wenchuan earthquake.

    Science.gov (United States)

    Zhou, Jixiang; Huang, Jiwei; Wu, Hong; Jiang, Hui; Zhang, Heqing; Prasoon, Pankaj; Xu, Yinglong; Bai, Yannan; Qiu, Jianguo; Zeng, Yong

    2012-10-01

    Abdominal injuries constitute a small proportion of all earthquake-related traumas; however, it often resulted in fatal hemorrhage. Ultrasonography has been described as an effective triage tool in the evaluation of blunt abdominal trauma. We aimed to present an overview of the diagnostic accuracy of screening ultrasonography for patients with blunt abdominal trauma admitted to various hospitals during the Wenchuan earthquake in China. We retrospectively analyzed the patients with blunt abdominal trauma who underwent ultrasonography after admission to various hospitals. Ultrasonography findings were considered positive if evidence of free fluid or a parenchymal injury was identified. Ultrasonography findings were compared with the findings of computed tomography, diagnostic peritoneal lavage, repeated ultrasonography, cystography, operation, and/or the clinical course. Findings from 2,204 ultrasonographic examinations were evaluated. Findings of 199 ultrasonographic examinations (9.0%) were considered positive. Of the patients, 12 (0.5%) had a false-negative ultrasonographic findings; of this group, 3 (25%) required exploratory laparotomy. Ultrasonography had a sensitivity of 91.9%, specificity of 96.9%, and an accuracy of 96.6% for detection of abdominal injuries. Positive predictive value was 68.3%, and negative predictive value was 99.4%. Screening ultrasonography is highly reliable in the setting of blunt abdominal trauma after earthquake. It should be used as an initial diagnostic modality in the evaluation of most blunt abdominal trauma. Diagnostic study, level III.

  6. Ultrasonography and computed tomography in the study of orbital tumors and pseudo-tumoral lesions

    International Nuclear Information System (INIS)

    Marins, J.L.C.; Pereira, R.M.; Prando, A.; Selos Moreira, A.R. de

    1987-01-01

    The computerized tomography and the ultrasonography in the ocular and orbital patologies were considered as complementary each other. the ultrasonography method as choice for the detection of the eye lesions in the adult, particularly of vascular origin and in the follow-up of inflammatory and pseudo-tumoral lesions was chosen. (L.M.J.) [pt

  7. The detection of prostatic carcinoma. 4- or 7-MHz transrectal ultrasonography?

    NARCIS (Netherlands)

    Vleeming, R.; Noordzij, J. W.; de Reijke, T. M.; Kurth, K. H.

    1993-01-01

    In this prospective study a comparison of 4-versus 7-MHz transrectal ultrasonography for the detection of prostatic carcinoma is reported. A total of 150 prostates were biopsied due to suspicion of malignancy arising at either digital rectal examination, 4- and/or 7-MHz transrectal ultrasonography,

  8. [A Multimedia Tutorial to Train Ultrasonography of the Thyroid for Medical Students].

    Science.gov (United States)

    Ritter, Julia; Wolfram, Maximilian; Schuler, Stefan; Guntinas-Lichius, Orlando

    2017-11-01

    Physicians in education often have poor experience in practice and assessment of ultrasonography on entering their profession, due to a deficiency of training offers during their study of medicine. Hence, a multimedia device for stepwise learning and training ultrasonography of the thyroid was developed. A software for a portable ultrasonography system was used to design a multimedia device for ultrasonography of the thyroid. It allows the user to illustrate texts and pictorial material simultaneously with ultrasound examination in order to compare own findings with examples from a database. The device was evaluated by 8 medical students and compared to a tutor-guided training. A structured, stepwise manual for ultrasonography of the thyroid with a large content of examples in different sectional images was designed for simultaneous reconstruction with the ultrasonography device. The informative content of the device and the replicability of the examination procedure were evaluated positively. Assessment respecting clarity, eligibility for users without experience and learning success was varying. The tutorial to learn and train ultrasonography of the thyroid is an instrument for self-learning and improving practical education in ultrasonography in medical education. In the next version, the manual for the examination will be structured in greater detail. © Georg Thieme Verlag KG Stuttgart · New York.

  9. P-THER-20: Biliary derivation by endoscopic ultrasound from gastric body in a patient with subtotal gastrectomy by gastric cancer

    Science.gov (United States)

    Arango, L.; Diaz, C.

    2017-01-01

    We present a biliary derivation from the gastric body in a patient with subtotal gastrectomy and anastomosis type Billroth I. The patient had a tumor obstruction of distal coledoco. The patient was with ictericia and the examinations indicated obstructive patron. A gastric transluminal derivation is made to common hepatic. Steps are as given below: Endosonography that locates the tumor obstruction of the coledoco shows the dilated hepatic conduct;Doppler signals are made that discharge vessels in the puncture route;The punction was made in gastric body with endosonographic window direct to the dilated common hepatic conduct. The puncton is performed with Boston Scientific 19-gauge needle;Bile was aspirated and contrast was injected to delineate the anatomy;We pass a hydrophilic guide of W. Cook 0.035 mm and after introduce a cystotomy of 6 Fr;Dilated the track is passed an autoexpandible stent covered of 60/10 mm. Patient evolves satisfactorily.

  10. A prospective comparison of transvaginal ultrasonography and diagnostic hysteroscopy in the evaluation of patients with abnormal uterine bleeding: clinical implications

    NARCIS (Netherlands)

    Emanuel, M. H.; Verdel, M. J.; Wamsteker, K.; Lammes, F. B.

    1995-01-01

    We determined the diagnostic value of transvaginal ultrasonography for endometrial and intrauterine abnormalities in patients with abnormal uterine bleeding. Between June 1, 1992, and June 1, 1993, 279 consecutive patients underwent transvaginal ultrasonography. Findings were compared with the final

  11. A prospective cross-sectional study of laparoscopic subtotal Lind fundoplication for gastro-oesophageal reflux disease--a durable and effective anti-reflux procedure.

    Science.gov (United States)

    Shapey, I M; Agrawal, S; Peacock, A; Super, P

    2015-01-01

    Laparoscopic partial fundoplication for gastro-oesophageal reflux disease (GORD) is reported to have fewer side effects when compared to Nissen fundoplication, but doubts remain over its long term durability in controlling reflux. The aim of this study was to assess outcome of symptoms for all patients presenting with GORD undergoing routine laparoscopic subtotal Lind fundoplication. All patients undergoing laparoscopic fundoplication between August, 1999 and November, 2007 performed by a single surgeon were included in the study. The anti-reflux procedure studied was laparoscopic Lind (300°) fundoplication with crural repair in all cases. Patients completed pre and post-operative questionnaires containing validated scoring systems for heartburn, gas bloat, dysphagia and overall patient satisfaction. Over the 100-month period, 320 consecutive patients underwent laparoscopic subtotal Lind fundoplication. Of these, 256 (80%) replied to the questionnaire at a mean of 31 months (range 3-96 months) following surgery. 91.4% of respondents had an improvement in heartburn symptom score with a significant reduction in score from 7.74 preoperatively to 1.25 postoperatively (preflux control (heartburn and regurgitation) from 3.49 preoperatively to 1.48 after surgery (preflux symptoms with half of these reporting their recurrence within two years following surgery. Because of this all were tested with post-operative pH testing, yet only one had a 24-h pH time outside the normal range. Overall patient satisfaction was high with a visual analogue score of 9 and 88% of the patients claimed they would have the operation again. Laparoscopic Lind fundoplication demonstrates excellent reflux control when performed routinely for all patients presenting with GORD. This technique is both durable and efficacious in controlling reflux symptoms. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  12. Muscle-tendon-related abnormalities detected by ultrasonography are common in symptomatic hip dysplasia

    DEFF Research Database (Denmark)

    Jacobsen, Julie Sandell; Bolvig, Lars; Hölmich, Per

    2018-01-01

    INTRODUCTION: Hip dysplasia is characterized by reduced acetabular coverage of the femoral head leading to an increased mechanical load on the hip joint and the acting hip muscles. Potentially, the muscles and tendons functioning close to the hip joint may present with overuse......-related ultrasonography findings. The primary aim was to report the prevalence of muscle-tendon-related abnormalities detected by ultrasonography in 100 patients with symptomatic hip dysplasia. The secondary aim was to investigate correlations between muscle-tendon-related abnormalities detected by ultrasonography......-tendon-related abnormalities detected by ultrasonography in the hip and groin region are common in patients with symptomatic hip dysplasia, and the ultrasonography findings of the iliopsoas and gluteus medius/minimus tendons are weakly to moderately correlated to pain related to muscles and tendons in these structures. Both...

  13. Ultrasonography and prostate-specific antigen (PSA) in differential diagnosis of prostate cancer and benign prostatic hyperplasia

    International Nuclear Information System (INIS)

    Mechev, D.S.; Shcherbyina, O.V.; Yatsik, V.Yi.; Gladka, L.Yu.

    2003-01-01

    The purpose of the work is analysis of diagnostic possibilities of transrectal ultrasonography and PSA in differential diagnosis of prostate cancer and benign prostatic hyperplasia. 142 patients have been investigated by transrectal ultrasonography. he transrectal ultrasonography and PSA are sensible tests in diagnosis of prostate cancer and in differential diagnosis of benign prostatic hyperplasia and prostate cancer

  14. Emergency ultrasonography of the gastrointestinal tract of children

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae Yeon [Dept. of Radiology, Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of)

    2017-07-15

    Ultrasonography (US) is widely used to evaluate most body parts in pediatric patients because it is simple, noninvasive, easy to use, and applicable in a wide variety of clinical situations. US is the modality of choice for the initial evaluation of acute abdominal pain in pediatric patients because of their small body habitus and the presence of less fat tissue in the abdominal wall and peritoneal cavity. The most important factor in performing pediatric emergency US is the graded compression technique and selection of the proper transducer. The careful evaluation of bowel wall thickening combined with ancillary findings such as fluid collection, increased echogenicity of the mesenteric fat tissue, enlarged lymph nodes, hyperemic bowel changes, and abnormal bowel peristalsis can increase the diagnostic capability of US.

  15. Ultrasonography-guided cobalt-60 brachytherapy for malignant glioma

    International Nuclear Information System (INIS)

    Sakai, Noboru; Takenaka, Katsunobu; Ueda, Tatsuya

    1989-01-01

    Brachytherapy with cobalt-60 source is reported. In this method it is characterized that the source is inserted interstitially with remote control system by after-loading method via outer catheter (using tandem tube), which was established in the center of residual tumor, using ultrasonography guide with trepanation, or intraoperatively put within the dead space after tumor resection. Six cases of deep-seated and recurrent malignant glioma, were treated with this method. A total dose of 20 to 45 Gy (10 to 15 Gy/day for 2 to 3 days) was delivered to the target. Additionally conventional external irradiation was followed. The effect of cobalt-60 brachytherapy on such tumors were favorable especially for well-circumscribed glioma less than 3 cm on CT scan. (author)

  16. Ultrasonography, CT, and ERCP in the diagnosis of choledochal stones

    International Nuclear Information System (INIS)

    Pasanen, P.; Partanen, K.; Pikkarainen, P.; Alhava, E.; Pirinen, A.; Janatuinen, E.

    1992-01-01

    A prospective study of jaundiced (n = 187) and nonjaundiced (n = 33) cholestatic patients was carried out to evaluate the sensitivity of ultrasonography (US), CT and endoscopic retrograde cholangiopancreatography (ERCP) in the detection of choledochal stone disease. Altogether 83 patients had the final diagnosis of choledocholithiasis. In the jaundiced patients, the sensitivity of US, CT, and ERCP was 22,5%, 23,2%, and 80,6%, respectively. In cases of cholestasis without jaundice, the values were 20%, 37,5%, and 66,7%. In patients in whom all 3 imaging studies were done (n = 64), the differences between US and ERCP and between CT and ERCP were statistically significant (p < 0.0001). In most false-negative ERCP studies (10/15), the clinical course of the disease strongly suggested a passed choledochal stone. On the basis of this study, we recommend prompt ERCP to be performed if choledochal stone disease is suspected on clinical grounds. (orig.)

  17. Medical auditing of whole-breast screening ultrasonography.

    Science.gov (United States)

    Kim, Min Jung

    2017-07-01

    Since breast ultrasonography (US) has been used as an adjunctive screening modality in women with dense breasts, the need has arisen to evaluate and monitor its possible harm and benefits in comparison with other screening modalities such as mammography. Recently, the fifth edition of the Breast Imaging Reporting and Data System published by the American College of Radiology has suggested auditing methods for screening breast US. However, the method proposed therein is slightly different from how diagnostic performance was calculated in previous studies on screening breast US. In this article, the background and core aspects of medical audits of breast cancer screening will be reviewed to provide an introduction to the medical auditing of screening breast US, with the goal of helping radiologists to understand and identify potential ways to improve outcomes.

  18. Contrast-Enhanced Ultrasonography in Crohn's Disease Diagnostics.

    Science.gov (United States)

    Białecki, Marcin; Białecka, Agnieszka; Laskowska, Katarzyna; Liebert, Ariel; Kłopocka, Maria; Serafin, Zbigniew

    2015-06-01

    The chronic nature of Crohn's disease (CD) implicates necessity of multiple control assessments throughout patient's life. It is accepted that in patients with CD requiring disease monitoring, magnetic resonance enterography (MRE) and computed tomography enterography (CTE) are--apart from endoscopy--imaging studies of first choice. In practice, diagnostic imaging of patients with CD is troublesome, since MRE is an expensive and complicated study, and CTE exposes patients to high doses of ionizing radiation. Therefore, there is a need for new, both non-invasive and effective, methods of imaging in CD. Contrast-Enhanced Ultrasonography (CEUS) is a relatively new method using gas-filled microbubbles serving as contrast agent. It allows for detailed assessment of blood perfusion within intestine wall and peri-intestinal tissues, which enables detection and monitoring of inflammation and its qualitative assessment. The purpose of this paper is to describe CEUS examination technique and its clinical applications in patients with Crohn's disease.

  19. The core content of clinical ultrasonography fellowship training.

    Science.gov (United States)

    Lewiss, Resa E; Tayal, Vivek S; Hoffmann, Beatrice; Kendall, John; Liteplo, Andrew S; Moak, James H; Panebianco, Nova; Noble, Vicki E

    2014-04-01

    The purpose of developing a core content for subspecialty training in clinical ultrasonography (US) is to standardize the education and qualifications required to provide oversight of US training, clinical use, and administration to improve patient care. This core content would be mastered by a fellow as a separate and unique postgraduate training, beyond that obtained during an emergency medicine (EM) residency or during medical school. The core content defines the training parameters, resources, and knowledge of clinical US necessary to direct clinical US divisions within medical specialties. Additionally, it is intended to inform fellowship directors and candidates for certification of the full range of content that might appear in future examinations. This article describes the development of the core content and presents the core content in its entirety. © 2014 by the Society for Academic Emergency Medicine.

  20. Medical auditing of whole-breast screening ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Jung [Dept. of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-07-15

    Since breast ultrasonography (US) has been used as an adjunctive screening modality in women with dense breasts, the need has arisen to evaluate and monitor its possible harm and benefits in comparison with other screening modalities such as mammography. Recently, the fifth edition of the Breast Imaging Reporting and Data System published by the American College of Radiology has suggested auditing methods for screening breast US. However, the method proposed therein is slightly different from how diagnostic performance was calculated in previous studies on screening breast US. In this article, the background and core aspects of medical audits of breast cancer screening will be reviewed to provide an introduction to the medical auditing of screening breast US, with the goal of helping radiologists to understand and identify potential ways to improve outcomes.

  1. Endoscopic ultrasonography and rectal duplication cyst in an adult.

    Science.gov (United States)

    Castro-Poças, Fernando M; Araújo, Tarcísio P; Silva, Jorge D; Gonçalves, Vicente S

    2017-01-01

    Rectal duplication cysts account for 4% of all duplications of the alimentary tract. Presentation in adulthood is rare. An asymptomatic 54-year-old man was referred for endoscopic colorectal cancer screening. A bulging mass covered by normal mucosa was identified in the rectum. Endoscopic ultrasonography (EUS) with fine needle aspiration (FNA) was made for a diagnosis of rectal duplication cyst. The patient was operated and the diagnosis was confirmed. The diagnosis of the rectal duplication cyst is a challenge. EUS may have a singular role when identifying a muscular layer, because this is the only absolutely necessary criterion for the diagnosis. FNA by EUS may eventually identify colorectal and/or heterotypic epithelium that are the other diagnostic criteria of the duplication cyst.

  2. Emergency ultrasonography of the gastrointestinal tract of children

    International Nuclear Information System (INIS)

    Hwang, Jae Yeon

    2017-01-01

    Ultrasonography (US) is widely used to evaluate most body parts in pediatric patients because it is simple, noninvasive, easy to use, and applicable in a wide variety of clinical situations. US is the modality of choice for the initial evaluation of acute abdominal pain in pediatric patients because of their small body habitus and the presence of less fat tissue in the abdominal wall and peritoneal cavity. The most important factor in performing pediatric emergency US is the graded compression technique and selection of the proper transducer. The careful evaluation of bowel wall thickening combined with ancillary findings such as fluid collection, increased echogenicity of the mesenteric fat tissue, enlarged lymph nodes, hyperemic bowel changes, and abnormal bowel peristalsis can increase the diagnostic capability of US

  3. Cholangiocarcinoma in Magnetic Resonance Cholangiopancreatography and Fascioliasis in Endoscopic Ultrasonography

    Directory of Open Access Journals (Sweden)

    Amir Houshang Mohammad Alizadeh

    2011-10-01

    Full Text Available Fascioliasis is a worldwide zoonotic infection with Fasciola hepatica and Fasciola gigantica. The zoonoses are particularly endemic in sheep-raising countries and are also endemic in Iran. Typical symptoms that may be associated with fascioliasis can be divided by phases of the disease, including the acute or liver phase, the chronic or biliary phase, and ectopic or pharyngeal fascioliasis. Cholestatic symptoms may be absent, and in some cases diagnosis and treatment may be preceded by a long period of abdominal pain, eosinophilia and vague gastrointestinal symptoms. We report a case with epigastric and upper quadrant abdominal pain for the last 4 years, with imaging suggesting cholangiocarcinoma. Considering a new concept of endoscopic ultrasonography, at last F. hepatica was extracted with endoscopic retrograde cholangiography.

  4. Clinical impact of endoscopic ultrasonography at a county hospital

    DEFF Research Database (Denmark)

    Ainsworth, A P; Mortensen, M B; Durup, J

    2002-01-01

    BACKGROUND AND STUDY AIMS: Although endoscopic ultrasonography (EUS) is a well-described examination method, there have been few reports concerning its clinical impact. The aim of this study was to describe EUS as it is performed at a county hospital, with an emphasis on the indications...... and clinical outcome. PATIENTS AND METHODS: Patients examined using EUS between December 1997 and November 2000 were recorded prospectively. Follow-up was conducted by examining each patient's medical records at least 3 months after the investigation. The EUS findings were compared with the patient's final...... management strategy in 80 patients (24 %). CONCLUSIONS: EUS has a high level of accuracy and a substantial clinical impact when performed in an unselected population. The estimated numbers of investigations needed appear to justify setting up an EUS center at institutions with a catchment population of 350...

  5. Ultrasonography of small intestinal obstructions: a contemporary approach.

    Science.gov (United States)

    Garcia, D A A; Froes, T R; Vilani, R G D O C; Guérios, S D; Obladen, A

    2011-09-01

    To assess the accuracy of intestinal ultrasound for diagnosis of intestinal obstruction in dogs and cats. A prospective clinical study was performed. Inclusion criteria were dogs and cats with clinical signs suggestive of gastrointestinal obstruction. Animals with no obstruction detected on ultrasound were excluded if they could not be monitored for 48 hours to confirm absence of obstruction. Sonographic diagnosis of small intestinal obstruction was based on identification of at least two findings suggestive of intestinal obstruction. Ninety-two patients suspected of having intestinal obstruction were included. Correct diagnosis of intestinal obstruction was made in 21 cases (23%), and in 68 (74%) this diagnosis was excluded. Interpretation of the images on prospective analysis had sensitivity, positive predictive, specificity and negative predictive values of 100%, 87.5%, 95.8% and 100%, respectively. Ultrasonography is an excellent method for investigation of animals with gastrointestinal disorders, and is particularly useful for excluding obstructive processes. © 2011 British Small Animal Veterinary Association.

  6. Bedside Ultrasonography: A Useful Tool For Traumatic Pneumothorax

    International Nuclear Information System (INIS)

    Mumtaz, U.; Zahur, Z.; Chaudhry, M. A.; Warraich, R. A.

    2016-01-01

    Objective: To compare the diagnostic accuracy of bedside ultrasound and supine chest radiography for the diagnosis of traumatic pneumothorax. Study Design: Analytical study. Place and Duration of Study: PIMS and PAEC General Hospital, Islamabad, from November 2014 to August 2015. Methodology: Patients coming to emergency departments of the study centres, who had sustained chest injuries, were inducted. Their portable bedside ultrasound and supine chest radiographs were taken for assessing pneumothorax and subsequently CT chest was done for confirmation as gold standard. Result: Based on CT findings, sensitivity for ultrasonography and chest radiography was found to be 83.33 percentage and 54.76 percentage, respectively and specificity of 100 percentage for both modalities. Conclusion: Ultrasound can be used as a useful and suitable adjunct to CT in trauma patients as it is easily available, non-invasive, bedside, easily examined with no radiation risk. (author)

  7. An audit of ultrasonography performed and reported by trainee radiologists.

    Science.gov (United States)

    Eze, K C; Marchie, T T; Eze, C U

    2009-01-01

    Proforma information, instructions and procedures of training in radiology are lacking in Nigeria. To describe the errors in ultrasonography performed by unsupervised trainee radiologists. The radiology records of all ultrasound scans (USS) carried out and all reports that came back to the unit of the authors on account of misdiagnosis, doubtful diagnosis, misinformation or error in the reports were studied. The patients with the returned reports were rescanned where available by consultants and the collected data analysed. A total of 4680 patients had ultrasound studies without supervision resulting in 605 (12.93%) queried reports. The USS scans of 235 (5.02%) patients were repeated with consultants in attendance resulting in significant change in reports of 95 (2.03%) patients. Analysis of the request cards of 605 queried reports showed omission of relevant clinical information 463 (76.53%), outright wrong information 65 (10.73%),and unconventional abbreviations 139 (22.98%), while 493 (81.49%) were completed by a nurse, medical student or junior resident. Typographical errors comprised 174 (28.76%) of the 605 queried reports. False negative error was the highest type of error seen in 55 (57.89%) of the 95 patients with significant change in their report after repeat scan as lesions not detected were not documented. Trainee radiologists make significant errors in carrying out and reporting ultrasonography without adequate direct supervision of the study by their training consultants. Majority of the errors originate from lack of accurate filling of the patients request cards by the requesting physicians, lack of adequate preparation for the intended study, and typographical errors in writing reports. False negative reports are by far the greatest cause of errors recorded as lesions not detected were not documented.

  8. Adaptive sound speed correction for abdominal ultrasonography: preliminary results

    Science.gov (United States)

    Jin, Sungmin; Kang, Jeeun; Song, Tai-Kyung; Yoo, Yangmo

    2013-03-01

    Ultrasonography has been conducting a critical role in assessing abdominal disorders due to its noninvasive, real-time, low cost, and deep penetrating capabilities. However, for imaging obese patients with a thick fat layer, it is challenging to achieve appropriate image quality with a conventional beamforming (CON) method due to phase aberration caused by the difference between sound speeds (e.g., 1580 and 1450m/s for liver and fat, respectively). For this, various sound speed correction (SSC) methods that estimate the accumulated sound speed for a region-of interest (ROI) have been previously proposed. However, with the SSC methods, the improvement in image quality was limited only for a specific depth of ROI. In this paper, we present the adaptive sound speed correction (ASSC) method, which can enhance the image quality for whole depths by using estimated sound speeds from two different depths in the lower layer. Since these accumulated sound speeds contain the respective contributions of layers, an optimal sound speed for each depth can be estimated by solving contribution equations. To evaluate the proposed method, the phantom study was conducted with pre-beamformed radio-frequency (RF) data acquired with a SonixTouch research package (Ultrasonix Corp., Canada) with linear and convex probes from the gel pad-stacked tissue mimicking phantom (Parker Lab. Inc., USA and Model539, ATS, USA) whose sound speeds are 1610 and 1450m/s, respectively. From the study, compared to the CON and SSC methods, the ASSC method showed the improved spatial resolution and information entropy contrast (IEC) for convex and linear array transducers, respectively. These results indicate that the ASSC method can be applied for enhancing image quality when imaging obese patients in abdominal ultrasonography.

  9. Contrast-enhanced endoscopic ultrasonography in digestive diseases.

    Science.gov (United States)

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2012-10-01

    Contrast-enhanced endoscopic ultrasonography (CE-EUS) was introduced in the early 1990s. The concept of the injection of carbon dioxide microbubbles into the hepatic artery as a contrast material (enhanced ultrasonography) led to "endoscopic ultrasonographic angiography". After the arrival of the first-generation contrast agent, high-frequency (12 MHz) EUS brought about the enhancement of EUS images in the diagnosis of pancreatico-biliary diseases, upper gastrointestinal (GI) cancer, and submucosal tumors. The electronic scanning endosonoscope with both radial and linear probes enabled the use of high-end ultrasound machines and depicted the enhancement of both color/power Doppler flow-based imaging and harmonic-based imaging using second-generation contrast agents. Many reports have described the usefulness of the differential diagnosis of pancreatic diseases and other abdominal lesions. Quantitative evaluation of CE-EUS images was an objective method of diagnosis using the time-intensity curve (TIC), but it was limited to the region of interest. Recently developed Inflow Time Mapping™ can be generated from stored clips and used to display the pattern of signal enhancement with time after injection, offering temporal difference of contrast agents and improved tumor characterization. On the other hand, three-dimensional CE-EUS images added new information to the literature, but lacked positional information. Three-dimensional CE-EUS with accurate positional information is awaited. To date, most reports have been related to pancreatic lesions or lymph nodes. Hemodynamic analysis might be of use for diseases in other organs: upper GI cancer diagnosis, submucosal tumors, and biliary disorders, and it might also provide functional information. Studies of CE-EUS in diseases in many other organs will increase in the near future.

  10. Interobserver agreement on the interpretation of automated whole breast ultrasonography

    International Nuclear Information System (INIS)

    Kim, Eun Jeong; KIm, Sung Hun; Kang, Bong Joo; Kim, Yun Ju

    2014-01-01

    The purpose of this study was to prospectively evaluate the interobserver agreement on lesion characterization and the final assessment of automated whole breast ultrasonography (ABUS) images. Between March and August 2012, 172 women underwent bilateral ABUS before biopsy guided by handheld ultrasonography (HHUS) and mammography. A total of 206 breast lesions were confirmed histopathologically by biopsy. Three-dimensional volume data from ABUS scans were analyzed by two radiologists without the knowledge of HHUS results or patient clinical information. The two readers described the type, shape, orientation, margin, echogenicity, posterior acoustic features, and categorization of the final assessment of detected breast lesions. Kappa statistics were used to analyze the described characteristics of the breast lesions detected by both of the two readers. Of the 206 histopathologically confirmed lesions, reader 1 detected 166 lesions and reader 2 detected 150 lesions. A total of 145 lesions were detected by both readers using ABUS images. There was substantial agreement on shape (k=0.707), and moderate agreement on type, margin, mass orientation, echogenicity, and posterior acoustic features (k=0.592, 0.438, 0.472, 0.524, and 0.541, respectively). Breast Imaging Reporting and Data System final assessment values yielded a kappa value of 0.3971 when category subdivisions 4A, 4B, and 4C were included. With respect to the C2, C3, C4, and C5 categories, the interobserver agreement was moderate (k=0.505). ABUS is a promising diagnostic tool with a good interobserver agreement, comparable to that of HHUS.

  11. Interobserver agreement on the interpretation of automated whole breast ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Jeong; KIm, Sung Hun; Kang, Bong Joo; Kim, Yun Ju [Dept. of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    The purpose of this study was to prospectively evaluate the interobserver agreement on lesion characterization and the final assessment of automated whole breast ultrasonography (ABUS) images. Between March and August 2012, 172 women underwent bilateral ABUS before biopsy guided by handheld ultrasonography (HHUS) and mammography. A total of 206 breast lesions were confirmed histopathologically by biopsy. Three-dimensional volume data from ABUS scans were analyzed by two radiologists without the knowledge of HHUS results or patient clinical information. The two readers described the type, shape, orientation, margin, echogenicity, posterior acoustic features, and categorization of the final assessment of detected breast lesions. Kappa statistics were used to analyze the described characteristics of the breast lesions detected by both of the two readers. Of the 206 histopathologically confirmed lesions, reader 1 detected 166 lesions and reader 2 detected 150 lesions. A total of 145 lesions were detected by both readers using ABUS images. There was substantial agreement on shape (k=0.707), and moderate agreement on type, margin, mass orientation, echogenicity, and posterior acoustic features (k=0.592, 0.438, 0.472, 0.524, and 0.541, respectively). Breast Imaging Reporting and Data System final assessment values yielded a kappa value of 0.3971 when category subdivisions 4A, 4B, and 4C were included. With respect to the C2, C3, C4, and C5 categories, the interobserver agreement was moderate (k=0.505). ABUS is a promising diagnostic tool with a good interobserver agreement, comparable to that of HHUS.

  12. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    Science.gov (United States)

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  13. Ultrasonography of pleural effusion. The quantification of minimal detectable volume

    International Nuclear Information System (INIS)

    Sustic, A.; Medved, I.; Ekl, D.; Simic, O.; Kovac, D.; Ivanis, N.

    2001-01-01

    Background. The aim of this study was to establish a minimal volume of free thoracic fluid in the pleural space of the supine cadaver detectable by ultrasonography. Material and methods. A prospective study with an experimental model on 20 cadavers (10 male, 10 female; age 66 ±11 yr.; height 172 ±9 cm; weight 75 ±12.6 kg; body surface area (BSA) 1.87 ±0.2 m 2 ) was used. Each cadaver was punctured bilaterally in 5 th or 6 th intercostal space at the medioclavicular line with venous cannula infusing in NaCl 0,9% solution at randomised speed in the chest. During the procedure the laterodorsal part of the thoracic wall next to the pulmonal base and phrenicocostal sinus was ultrasonographically scanned. At the moment of the visualisation of anechogenic line pertaining to the free fluid between dorsal thoracic wall and lungs, the installation was stopped and the amount of injected fluid verified. Results. Minimal, by ultrasonography detectable amount of free fluid in the right pleural space was 223±52 ml with the significant positive correlation to height (r = 0.69; p < 0.001), weight (r 0.68; p < 0.01) and the BSA (r = 0.71; p < 0.001) of cadaver. Detectable volume in the left pleural space was notably smaller than contra lateral, namely 172±53 ml also with a significant correlation to the cadaver's height (r = 0.55; p < 0.05), weight (r = 0.59; p < 0.01) and BSA (r = 0.60; p < 0.01). Conclusions. The authors affirm that ultrasonographically detectable quantity of free fluid in the chest positively correlates with height, weight and BSA of cadavers, and that the measured amount in the supine position is approximately 223 ml for the right space versus 172 ml for the left pleural space. (author)

  14. Feasibility of ultrasonography and MR arthrography during evaluation of rotator cuff injury

    International Nuclear Information System (INIS)

    Hu, Jin Guang; Lee, Jong Min; Ryeom, Hun Kyu

    2005-01-01

    To evaluate the feasibility of MR arthrography and ultrasonography in evaluating shoulder pain. The subject group consisted of all patients who visited our institute complaining of shoulder pain or instability form June 2002 to December 2004. There were a total of 92 patients with an mean age of 48. On the basis of arthroscopic results, the sensitivity, specificity, and accuracy of ultrasonography and MR arthrography were evaluated by comparing them with each other. In the diagnosis of separateness tendon tears, ultrasonography had sensitivity and specificity of 100% and 64%, respectively, whereas MR arthrography had sensitivity and specificity of 80% and 94%, respectively. Ultrasonography also had high sensitivity and specificity in the diagnosis of subscapularis tendon tears (100% and 90%). MR arthrography was appropriate for identifying glenoid labral abnormalities (sensitivity, 95% and specificity, 61%). Similar results from ultrasonography and MR arthrography were obtained in the diagnosis of subscapular tendon tears or full-thickness tears of the rotator cuff tendons (kappa value, 0.644 and 0.911). While evaluating rotator cuff abnormalities, ultrasonography was appropriate for screening, whereas MR arthrography was useful to confirm the results of the ultrasonography

  15. Comparison between mammography and ultrasonography for palpable breast mass: focusing fibroadenoma and breast cancer

    International Nuclear Information System (INIS)

    Kim, Do Kyun; Koh, Mi Kyung; Choi, Chul Soon; Chung, Soo Young; Yi, Jeong Geun; Yoon, Dae Young; Kim, Ho Chul; Bae, Sang Hoon

    1997-01-01

    The purpose of our study was to compare the diagnostic accuracy of mammography and breast ultrasonography between fibroadenoma and palpable breast cancer and to evaluate the feasibility of ultrasonography as a primary diagnostic modality to differentiate between these two tumor types. In 36 cases of fibroadenoma and 35 of breast cancer, all palpable and pathologically-proven, the diagnostic accuracy of mammography and ultrasonography was retros-pectively analysed. In fibroadenoma cases, the diagnostic accuracy of mammography and ultrasonography was 53% and 80%, respectively, and the difference was statistically significant(p=3D0.0162). In cases of breast cancer, the corresponding figures were 74% and 82%, respectively;the difference was not statistically signigicant(p-0.55). Overall, the diagnostic accuracy of mammography and ultrasonog-raphy was 63% and 82%, respectively, and this difference was statistically significant(p=3D0.0164). The total diagnostic accuracy of both studies was 90%, and this was signigicantly different(p=3D0.044) from that of ultrasonography(82%). In patients who have clinically palpable breast masses, ultrasonography can be recommended as the primary diagnostic modality, though for other breast lesions, mammography is the recommended primary modality.=20

  16. Comparison between mammography and ultrasonography for palpable breast mass: focusing fibroadenoma and breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Kyun; Koh, Mi Kyung; Choi, Chul Soon; Chung, Soo Young; Yi, Jeong Geun; Yoon, Dae Young; Kim, Ho Chul; Bae, Sang Hoon [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-09-01

    The purpose of our study was to compare the diagnostic accuracy of mammography and breast ultrasonography between fibroadenoma and palpable breast cancer and to evaluate the feasibility of ultrasonography as a primary diagnostic modality to differentiate between these two tumor types. In 36 cases of fibroadenoma and 35 of breast cancer, all palpable and pathologically-proven, the diagnostic accuracy of mammography and ultrasonography was retros-pectively analysed. In fibroadenoma cases, the diagnostic accuracy of mammography and ultrasonography was 53% and 80%, respectively, and the difference was statistically significant(p=3D0.0162). In cases of breast cancer, the corresponding figures were 74% and 82%, respectively;the difference was not statistically signigicant(p-0.55). Overall, the diagnostic accuracy of mammography and ultrasonog-raphy was 63% and 82%, respectively, and this difference was statistically significant(p=3D0.0164). The total diagnostic accuracy of both studies was 90%, and this was signigicantly different(p=3D0.044) from that of ultrasonography(82%). In patients who have clinically palpable breast masses, ultrasonography can be recommended as the primary diagnostic modality, though for other breast lesions, mammography is the recommended primary modality.=20.

  17. Comparison of helical computed tomography and ultrasonography in diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Nafees, M.; Abbas, G.; Sarwar, S.

    2010-01-01

    The objective of study is to compare the diagnostic accuracy of helical computed tomography and ultrasonography in acute appendicitis using histopathology as gold standard. Thirty cases of clinically suspected acute appendicitis were included in the study selected on non probability convenience sampling technique. Computed tomography and graded compression ultrasonography of right lower quadrant of abdomen were conducted and results compared with histopathological findings. Amongst 30 patients who underwent computed tomography and graded compression ultrasonography examinations of right lower quadrant for diagnosis of acute appendicitis, on computed tomography 19 were diagnosed with acute appendicitis, 10 were diagnosed as not having the disease and 01 patient diagnosed as not having appendicitis on computed tomography did not improve clinically, was operated upon and histopathology proved it as acute appendicitis. While on graded compression ultrasonography 15 were diagnosed with acute appendicitis, 11 were diagnosed as not having the disease and 04 patients diagnosed as not having appendicitis on ultrasonography, did not improve clinically, were operated upon and histopathology proved it as acute appendicitis. This showed that CT scan has sensitivity of 95%, specificity 100%, positive predictive value 100%, negative predictive value 90.91% and overall accuracy of 96.67% while ultrasonography has sensitivity of 78.9%, specificity 100%, positive predictive value 100%, negative predictive value 73.33% and overall accuracy of 86.67%. We concluded that Helical computed tomography is highly accurate in diagnosing acute appendicitis as compared to ultrasonography and it helps to reduce negative appendectomy rate. (author)

  18. Pretreatment Evaluation with Contrast-Enhanced Ultrasonography for Percutaneous Radiofrequency Ablation of Hepatocellular Carcinomas with Poor Conspicuity on Conventional Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Ah Yeong; Lee, Min Woo; Rhim, Hyunchul; Cha, Dong Ik; Choi, Dongil; Kim, Young-sun; Lim, Hyo Keun; Cho, Seong Whi

    2013-01-01

    To determine whether pretreatment evaluation with contrast-enhanced ultrasonography (CEUS) is effective for percutaneous radiofrequency ablation (RFA) of hepatocellular carcinoma (HCC) with poor conspicuity on conventional ultrasonography (US). This retrospective study was approved by the institutional review board and informed consent was waived. From June 2008 to July 2011, 82 patients having HCCs (1.2 ± 0.4 cm) with poor conspicuity on planning US for RFA were evaluated with CEUS prior to percutaneous RFA. We analyzed our database, radiologic reports, and US images in order to determine whether the location of HCC candidates on planning US coincide with that on CEUS. To avoid incomplete ablation, percutaneous RFA was performed only when HCC nodules were identified on CEUS. The rate of technical success was assessed. The cumulative rate of local tumor progression was estimated with the use of the Kaplan-Meier method (mean follow-up: 24.0 ± 13.0 months). Among 82 patients, 73 (89%) HCCs were identified on CEUS, whereas 9 (11%) were not. Of 73 identifiable HCCs on CEUS, the location of HCC on planning US corresponded with that on CEUS in 64 (87.7%), whereas the location did not correspond in 9 (12.3%) HCCs. Technical success was achieved for all 73 identifiable HCCs on CEUS in a single (n = 72) or two (n = 1) RFA sessions. Cumulative rates of local tumor progression were estimated as 1.9% and 15.4% at 1 and 3 years, respectively. Pretreatment evaluation with CEUS is effective for percutaneous RFA of HCCs with poor conspicuity on conventional US

  19. Infusion tomography and ultrasonography of the gallbladder in the diagnosis of acute cholecystitis

    International Nuclear Information System (INIS)

    Karp, W.; Owman, T.; Herlin, P.; Holmin, T.

    1979-01-01

    Sixty-three patients with the clinical suspicion of acute cholecystitis were examined with infusion tomography of the gallbladder. Ultrasonography was performed in 51 of these cases. The technique and diagnostic principles of both methods are discussed. The diagnostic value of the two methods when used in combination is stressed. Thus in a case of gangrenous cholecystitis when opacification of the gallbladder wall may not appear at infusion tomography, ultrasonography may demonstrate signs of gallbladder disease. Infusion tomography, on the other hand, may be of great value if ultrasonography is not informative. (orig.) 891 AJ/orig. 892 BRE [de

  20. Shear-wave elastography in breast ultrasonography: the state of the art

    Directory of Open Access Journals (Sweden)

    Ji Hyun Youk

    2017-10-01

    Full Text Available Shear-wave elastography (SWE is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy.

  1. Shear-wave elastography in breast ultrasonography: the state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Youk, Ji Hyun; Gweon, Hye Mi; Son, Eun Ju [Dept. of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    Shear-wave elastography (SWE) is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy.

  2. Determination of gestational age by ultrasonography - wrong, wrong and wrong again?

    International Nuclear Information System (INIS)

    Bratlid, D.

    1991-01-01

    The article is a critical review of principal weaknesses in the current use of ultrasonography for determination of gestational age and discusses the fact that the method in its practical use disregards any biological variation in biparietal diameter. It is concluded that second trimester determination of gestational age by ultrasonography has an accuracy no greater than ±1.5 weeks. This is comparable to the accuracy of the clinical assessment of maturation in the newborn baby. Ultrasonography as the main indicator of gestational age should be used only when the pregnant woman's own menstrual history is obviously incorrect. 6 refs., 1 fig

  3. Validation of ultrasonography in detecting structural disease of the urogenital tract of the koala, Phascolarctos cinereus.

    Science.gov (United States)

    Marschner, C; Flanagan, C; Higgins, D P; Krockenberger, M B

    2014-05-01

    A retrospective review of case records of ultrasonography and necropsy outcomes of 62 koalas was used to investigate the accuracy of ultrasonography in assessing koala urogenital tract structural disease at the Port Macquarie Koala Hospital. The results showed high concordance, supporting ultrasonography as an effective tool for evaluating structural disease of the koala urogenital tract, most commonly seen with chlamydiosis. The study also illustrates the advances benefiting animal welfare that can be made by wildlife carer groups through using a scientific, evidence-based approach. © 2014 Australian Veterinary Association.

  4. [Ultrasonography-guided therapeutic procedures in the neck region].

    Science.gov (United States)

    Brzac, Hrvojka Tomić

    2009-12-01

    Minimally invasive therapeutic procedures in medicine have become very popular because of the reduced risk compared to classic surgical treatment, speed of recovery, little or no side effects, and frequently lower cost. One of these methods is ultrasonography-guided percutaneous injection of 95% ethanol (PEIT, percutaneous ethanol injection therapy), which is especially suitable for the neck region. Other methods like laser photocoagulation (ILP) or radiofrequency ablation (RFA) are more aggressive and expensive. The procedure of sterile 95% ethanol injecting is performed on an outpatient basis, without preparation. A specific amount of alcohol is injected into the lesion using a thin spinal needle, under ultrasonography guidance. The amount of alcohol depends on the size of the lesion. Complications are rare and the procedure can be repeated several times. PEIT is used in the treatment of parathyroid glands, especially secondary hyperparathyroidism, thyroid nodules (toxic adenoma, goiters and cysts), other cysts on the neck, and cervical metastases of thyroid cancer. Direct ethanol injection into the tissue causes cellular dehydration and protein denaturation, followed by the development of necrosis, fibrosis, and thrombosis of the small blood vessels. In this way, reduction or disappearance of the nodes can be achieved, along with functional normalization (for parathyroid glands and toxic adenoma), with longer or shorter disease remission or complete recovery. Today, PEIT is mostly used in dialyzed patients with secondary hyperparathyroidism. The treatment gives best results in combination with vitamin D analogs, if 1-2 parathyroid glands are enlarged, and for residual parathyroid gland after parathyroidectomy. A success rate of 50%-70% has been reported, depending on the number of enlarged parathyroid glands. Therapeutic effect is manifested in the size reduction or complete fibrozation of the gland, reduction or disappearance of vascularization, and a decrease

  5. [Diagnostic utility of endoscopic ultrasonography elastography and contrast-enhanced harmonic endoscopic ultrasonography in a patient with type 2 autoimmune pancreatitis].

    Science.gov (United States)

    Yokode, Masataka; Shiomi, Hideyuki; Itai, Ryosuke; Mikami, Sakae; Yamashita, Yukimasa; Nakano, Ryota; Ezaki, Takeshi; Masuda, Atsuhiro; Zen, Yoh

    2018-01-01

    A referring hospital diagnosed a 57-year-old man with a pancreatic head mass. The initial endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) was inconclusive because of the small sample size. Endoscopic ultrasonography elastography (EUS-EG) and contrast-enhanced harmonic endoscopic ultrasonography (CE-EUS), conducted at our institute, raised the possibility of mass-forming pancreatitis or autoimmune pancreatitis (AIP). A repeat EUS-FNA revealed inflammatory changes, including a neutrophilic duct injury suggestive of type 2 AIP. The pancreatic lesion responded well to the steroid therapy. The present case suggests that EUS-EG and CE-EUS may be useful for diagnostic exclusion of pancreatic cancers, and the combined use of EUS-EG and CE-EUS, with EUS-FNA, may help characterize inflammatory pancreatic lesions.

  6. Discrepancy between ultrasonography and hysteroscopy and histology of endometrium in postmenopausal breast cancer patients using tamoxifen

    NARCIS (Netherlands)

    Mourits, MJE; Van der Zee, AGJ; Willemse, PHB; Ten Hoor, KA; Hollema, H; De Vries, EGE

    Background. The increased risk of endometrial carcinoma following the use of tamoxifen has stimulated studies on endometrial diagnostic screening methods. In tamoxifen users the endometrial thickening observed with transvaginal ultrasonography (TVU) frequently cannot be confirmed by hysteroscopy or

  7. Comparison of Radiography and Ultrasonography for Diagnosis of Diaphragmatic Hernia in Bovines

    Directory of Open Access Journals (Sweden)

    Hakim Athar

    2010-01-01

    Full Text Available The present study was conducted on 101 animals suffering from thoracoabdominal disorders; out of which twenty seven animals (twenty six buffaloes and one cow were diagnosed with diaphragmatic hernia based on clinical signs, radiography, ultrasonography, and left flank laparorumenotomy. Radiography alone confirmed diaphragmatic hernia in 18 cases (66.67% with a sac-like structure cranial to the diaphragm. In 15 animals the sac contained metallic densities while in three cases a sac-like structure with no metallic densities was present. Ultrasonography was helpful in confirming diaphragmatic hernia in 23 cases (85.18% and ultrasonographically reticular motility was evident at the level of 4th/5th intercostal space in all the animals. B+M mode ultrasonography was used for the first time for diagnosis of diaphragmatic hernia in bovines and the results suggested that ultrasonography was a reliable diagnostic modality for diaphragmatic hernia in bovines.

  8. Ultrasonography of pediatric urogenital emergencies: review of classic and new techniques

    Directory of Open Access Journals (Sweden)

    Masahiro Kitami

    2017-07-01

    Full Text Available Urogenital emergencies are fairly common in the pediatric population, and a timely and correct diagnosis is necessary to avoid possible future infertility. In this field, ultrasonography is essential, as it has the advantages of being radiation-free and readily accessible. In particular, a high-frequency transducer allows precise evaluation of the morphology and vascularity of the scrotum, which is on the surface of the body. Beyond conventional techniques, new advanced imaging techniques have been developed, including elastography and contrast-enhanced ultrasonography. However, several pitfalls remain in the diagnosis of urogenital diseases using ultrasonography. Thus, accurate knowledge and sufficient experience with the technique are essential for making a correct diagnosis. This review provides an overview of pediatric urogenital emergency pathologies and recent ultrasonography techniques.

  9. Reliability of ultrasonography in detecting shoulder disease in patients with rheumatoid arthritis.

    LENUS (Irish Health Repository)

    Bruyn, G A W

    2009-03-01

    To assess the intra and interobserver reproducibility of musculoskeletal ultrasonography (US) among rheumatologists in detecting destructive and inflammatory shoulder abnormalities in patients with rheumatoid arthritis (RA) and to determine the overall agreement between US and MRI.

  10. Ultrasonography of pediatric urogenital emergencies: review of classic and new techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kitami, Masahiro [Dept. of Diagnostic Radiology, Tohoku University Graduate School of Medicine, Sendai (Japan)

    2017-07-15

    Urogenital emergencies are fairly common in the pediatric population, and a timely and correct diagnosis is necessary to avoid possible future infertility. In this field, ultrasonography is essential, as it has the advantages of being radiation-free and readily accessible. In particular, a high-frequency transducer allows precise evaluation of the morphology and vascularity of the scrotum, which is on the surface of the body. Beyond conventional techniques, new advanced imaging techniques have been developed, including elastography and contrast-enhanced ultrasonography. However, several pitfalls remain in the diagnosis of urogenital diseases using ultrasonography. Thus, accurate knowledge and sufficient experience with the technique are essential for making a correct diagnosis. This review provides an overview of pediatric urogenital emergency pathologies and recent ultrasonography techniques.

  11. The use of multi-detector computed tomography and ultrasonography for evaluation of pleural lesions

    Directory of Open Access Journals (Sweden)

    Adel Salah Bediwy

    2015-01-01

    Conclusion: MDCT is an important noninvasive imaging tool in accurate detection and characterization of pleural lesions with complementary MPR images that solve many diagnostic problems. Ultrasonography is a safer alternative but with less diagnostic value.

  12. Imaging of juvenile spondyloarthritis. Part II: Ultrasonography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Iwona Sudoł-Szopińska

    2017-09-01

    Full Text Available Juvenile spondyloarthropathies are mainly manifested by symptoms of peripheral arthritis and enthesitis. Early involvement of sacroiliac joints and spine is exceptionally rare in children; this usually happens in adulthood. Conventional radiographs visualize late inflammatory lesions. Early diagnosis is possible with the use of ultrasonography and magnetic resonance imaging. The first part of the article presented classifications and radiographic presentation of juvenile spondyloarthropathies. This part discusses changes seen on ultrasonography and magnetic resonance imaging. In patients with juvenile spondyloarthropathies, these examinations are conducted to diagnose inflammatory lesions in peripheral joints, tendon sheaths, tendons and bursae. Moreover, magnetic resonance also shows subchondral bone marrow edema, which is considered an early sign of inflammation. Ultrasonography and magnetic resonance imaging do not show specific lesions for any rheumatic disease. Nevertheless, they are conducted for early diagnosis, treatment monitoring and identifying complications. This article presents a spectrum of inflammatory changes and discusses the diagnostic value of ultrasonography and magnetic resonance imaging.

  13. Reliability of ultrasonography in detecting shoulder disease in patients with rheumatoid arthritis

    NARCIS (Netherlands)

    Bruyn, G. A. W.; Naredo, E.; Moeller, I.; Moragues, C.; Garrido, J.; de Bock, G. H.; d'Agostino, M-A; Filippucci, E.; Iagnocco, A.; Backhaus, M.; Swen, W. A. A.; Balint, P.; Pineda, C.; Milutinovic, S.; Kane, D.; Kaeley, G.; Narvaez, F. J.; Wakefield, R. J.; Narvaez, J. A.; de Augustin, J.; Schmidt, W. A.; Moller, I.; Swen, N.; de Agustin, J.

    Objective: To assess the intra and interobserver reproducibility of musculoskeletal ultrasonography ( US) among rheumatologists in detecting destructive and inflammatory shoulder abnormalities in patients with rheumatoid arthritis ( RA) and to determine the overall agreement between US and MRI.

  14. Solitary extramedullary plasmacytomas of thyroid in Hashimoto's thyroiditis: Mimicking benign cystic nodule on ultrasonography

    International Nuclear Information System (INIS)

    Kwon, Yohan; Kim, Soo Jin; Hur, Joon Ho; Park, Sung Hee; Lee, Sun Jin; Lee, Tae Jin

    2013-01-01

    Solitary extramedullary plasmacytoma (SEP) of the thyroid is uncommon and mostly occur in patients with a Hashimoto's thyroiditis (82%). We present a case on SEP of thyroid in Hashimoto's thyroiditis, which mimics growing benign cystic masses on serial ultrasonography.

  15. An economic evaluation of second-trimester genetic ultrasonography for prenatal detection of down syndrome.

    Science.gov (United States)

    Vintzileos, A M; Ananth, C V; Fisher, A J; Smulian, J C; Day-Salvatore, D; Beazoglou, T; Knuppel, R A

    1998-11-01

    The objective of this study was to perform an economic evaluation of second-trimester genetic ultrasonography for prenatal detection of Down syndrome. More specifically, we sought to determine the following: (1) the diagnostic accuracy requirements (from the cost-benefit point of view) of genetic ultrasonography versus genetic amniocentesis for women at increased risk for fetal Down syndrome and (2) the possible economic impact of second-trimester genetic ultrasonography for the US population on the basis of the ultrasonographic accuracies reported in previously published studies. A cost-benefit equation was developed from the hypothesis that the cost of universal genetic amniocentesis of patients at increased risk for carrying a fetus with Down syndrome should be at least equal to the cost of universal genetic ultrasonography with amniocentesis used only for those with abnormal ultrasonographic results. The main components of the equation included the diagnostic accuracy of genetic ultrasonography (sensitivity and specificity for detecting Down syndrome), the costs of the amniocentesis package and genetic ultrasonography, and the lifetime cost of Down syndrome cases not detected by the genetic ultrasonography. After appropriate manipulation of the equation a graph was constructed, representing the balance between sensitivity and false-positive rate of genetic ultrasonography; this was used to examine the accuracy of previously published studies from the cost-benefit point of view. Sensitivity analyses included individual risks for Down syndrome ranging from 1:261 (risk of a 35-year-old at 18 weeks' gestation) to 1:44 (risk of a 44-year-old at 18 weeks' gestation). This economic evaluation was conducted from the societal perspective. Genetic ultrasonography was found to be economically beneficial only if the overall sensitivity for detecting Down syndrome was >74%. Even then, the cost-benefit ratio depended on the corresponding false-positive rate. Of the 7

  16. Effect of Ultrasonography on Student Learning of Shoulder Anatomy and Landmarks.

    Science.gov (United States)

    de Vries, Kristen D; Brown, Rebecca; Mazzie, Joseph; Jung, Min-Kyung; Yao, Sheldon C; Terzella, Michael J

    2018-01-01

    Ultrasonography is becoming more common in clinical use, and it has been shown to have promising results when introduced into medical school curricula. To determine whether the use of ultrasonography as an educational supplement can improve osteopathic medical students' confidence and ability to locate 4 specific shoulder anatomical landmarks: the coracoid process, the transverse process of T1, the long head of the biceps within the bicipital groove, and the supraspinatus tendon. In this randomized controlled study, first-year osteopathic medical students aged 18 years or older were recruited and randomly assigned to a group with exposure (ultrasonography group) or without exposure (control group) to an ultrasonography machine. First, a survey was administered to measure students' baseline knowledge of shoulder anatomy, confidence in palpation skills, and opinion on anatomical landmark identification teaching methods. Next, students were shown presentations on shoulder anatomy and allowed to practice locating and palpating the specified landmarks. Students in the ultrasonography group were also given instruction on the use of ultrasonography. All students were asked to locate each of the 4 specified anatomical landmarks and then given a follow-up survey. A Mann Whitney U test was used to compare the confidence of the students before and after the intervention. A secondary analysis was performed to compare the degree of deviance from the correct position of the specified anatomical landmark between the ultrasonography and control groups. P values less than .05 were considered statistically significant. Sixty-four students participated. Compared with the control group, students in the ultrasonography group had a greater increase in confidence after the session in their ability to locate the coracoid process, bicipital tendon, and supraspinatus tendon (P=.022, P=.029, P=.44, respectively). Students in the ultrasonography group were also able to more accurately palpate

  17. HIGH-RESOLUTION ULTRASONOGRAPHY OF SHOULDER FOR ROTATOR CUFF TEAR: CORRELATION WITH ARTHROSCOPIC FINDINGS

    OpenAIRE

    Vishnumurthy H. Y; Jagdeesh K. S; Anand K; Ranoji Mane; Sanath G. Kamte; Fathima Zohra; Banerji B. H; Sathish Servegar

    2016-01-01

    INTRODUCTION Rotator cuff disease is the most common cause of shoulder pain. Ultrasonography being non-invasive, widely available, more cost-effective method and is the first choice in imaging of rotator cuff tears. Arthroscopy of shoulder is considered as the gold standard for diagnosis of rotator cuff tears. Objective of this study was to compare the diagnostic accuracy of high-resolution ultrasonography of shoulder for rotator cuff tears with arthroscopy of shoulder. METHODS...

  18. Two cases of posterior scleritis and findings of computerized tomography and ultrasonography

    International Nuclear Information System (INIS)

    Ohara, Takakazu; Uji, Yukitaka; Fujioka, Chieko; Mori, Kazuma

    1982-01-01

    Two cases of unilateral posterior scleritis, seen in 56-year-old and 68-year-old females, are reported. Computerized tomography showed characteristic findings, as follows: 1) Thickening of the posterior sclera and surrounding tissue. 2) Irregularity of the posterior wall of the eyeball. 3) Increased radiographic density in the posterior wall of the eyeball. Ultrasonography also suggested thickening of the posterior sclera. Computerized tomography and ultrasonography are considered useful in the diagnosis of posterior scleritis. (author)

  19. Comparison of ultrasonography with radiography for the detection of cervical esophageal foreign body

    OpenAIRE

    Reza Pourrashidi; Shervin Sharifkashani; Hashem Sharifian; Habib Mazaher; Peyman Salamati; Batool Ghorbani yekta

    2013-01-01

    Background: Detection of retained foreign bodies remains a significant problem in the emergency department. Foreign bodies can go undetected causing infectious complications ultrasonography is too inaccessible and expensive. The purpose of this study is comparison of ultrasonography with radiography for the detection of cervical esophageal foreign bodiesMethods: This cross-sectional study evaluated 58 patients referred with suspected upper esophageal foreign body in the Emergency Department, ...

  20. Positioning Ultrasonography Into Clinical Practice for the Management of Crohn’s Disease

    Science.gov (United States)

    Zorzi, Francesca; Lolli, Elisabetta; Pallone, Francesco

    2015-01-01

    Over the past few years, the technical evolution of ultrasound equipment, the use of oral and intravenous contrast agents, and an increase in the expertise of operators have enhanced the role that ultrasonography plays in the assessment of the gastrointestinal tract. For patients with chronic inflammatory conditions, particularly Crohn’s disease, it has been suggested that ultrasonography can be used not only for diagnostic purposes but also in disease management. These developments are reviewed in this article. PMID:27118932

  1. Computed tomography, ultrasonography, and endoscopic retrograde cholangiopancreatography in the diagnosis of pancreatic disease

    International Nuclear Information System (INIS)

    Foley, W.D.; Stewart, E.T.; Lawson, T.L.; Maher, L.; Unger, G.F.; Geenan, J.; Loguidice, J.

    1980-01-01

    A prospective study was performed comparing the sensitivity of computed tomography, ultrasonography, and endoscopic retrograde cholangiopancreatography (ERCP) in the diagnosis of pancreatic disease. Forty patients with suspected pancreatic carcinoma, acute recurrent or chronic pancreatitis, and/or jaundice were studied. CT was the most sensitive study in evaluation of pancreatitis. ERCP was most accurate in evaluation of pancreatic malignancy. Ultrasonography was the least sensitive method in detecting pancreatic disease and dilatation of the extrahepatic biliary ducts. (orig.) [de

  2. Role of ultrasonography in detecting mammographically occult breast carcinoma in women with dense breasts.

    Science.gov (United States)

    Corsetti, V; Ferrari, A; Ghirardi, M; Bergonzini, R; Bellarosa, S; Angelini, O; Bani, C; Ciatto, S

    2006-04-01

    The purpose of this study was to assess the usefulness of routine ultrasonography in women with negative mammography and dense breasts [Breast Imaging Reporting and Data System (BIRADS D3-4)]. We applied a protocol involving routine ultrasonography in a consecutive series of subjects with negative mammography and dense breasts. After evaluation by internal and external reviewers of cancers detected by ultrasonography performed to confirm negative mammography, we determined the additional cancer detection rate of ultrasonography and the cost of the protocol. Out of 17,883 total mammographies, 167 cancers were diagnosed (detection rate: 0.93%). Out of 257 suspicious mammographies, 138 cancers were detected. Out of 17,626 negative mammographies, 6,449 (36.5%) were classified as "dense breast" and underwent ultrasonography: 29 cancers were detected (detection rate: 0.44%, or 17.3% of total cancers). Out of 25 cancer cases reviewed, negative mammography and asymptomatic status was confirmed in 15 (detection rate 0.23%, or 8.9% of total cancers). The cancer detection rate was 0.11%, 0.22%, 0.32% and 0.14% for age groups 59, respectively. The cost per additional carcinoma detected by ultrasonography alone was euro 25,847.85 whereas that per examined woman was euro 21.68. The study confirms the possibility that ultrasonography can detect mammographically occult breast carcinoma in dense breasts. The evidence is insufficient to recommend this policy in routine screening practice but suggests that, at least in current clinical practice, adding ultrasonography in dense breasts may be useful despite the substantial costs.

  3. A prospective clinical trial to assess the efficacy of radioiodine ablation as an alternative to completion thyroidectomy in patients with differentiated thyroid cancer undergoing sub-total thyroidectomy

    International Nuclear Information System (INIS)

    Bal, C.S.; Kumar, Ajay; Pant, G.S.; Chandra, Prem; Dwivedi, S.N.

    2006-01-01

    We conducted a prospective clinical trial to evaluate whether radioiodine ablation can be an effective alternative to completion thyroidectomy in patients undergoing sub-total thyroidectomy and if yes, the optimum activity of 131 I and frequency of ablation. A total of 85 patients (F-63; M-22) with mean age of 37.9±12.3 years were recruited in this study. The pre-ablation mean 24 hour radioiodine neck uptake, effective half-life, residual thyroid tissue weight and TSH values were 13.9±8.5%, 4.5±0.9 days, 9.6±3.6 g and 11.7±6.4 μIU/ml, respectively. Thyroid tissue was completely ablated in 50 patients (58.8%, 95% CI:50-68%) after mean 1st administered activity of 32.3±10.7 mCi of 131 I and the cumulative ablation rate was 91.8% after two doses of 131 I. During mean follow-up duration of 49 months no local/distant recurrence has been observed so far in this cohort. It appears that radioiodine ablation may be an attractive alternative to completion thyroidectomy and an activity as low as 35 mCi may achieve reasonable ablation

  4. Laparoscopic subtotal hysterectomy using the plasma kinetic and lap loop systems: an alternative approach in the surgical management of women with uterine fibroids.

    Science.gov (United States)

    Erian, John; El-Shawarby, Salem A; Hassan, Mohsen; Wissa, Ihab; Chandakas, Stefanos; Hill, Nicholas

    2008-03-01

    To evaluate the safety and applicability of laparoscopic subtotal hysterectomy (LSH) using the plasma kinetic (PK) and lap loop systems as an alternative surgical approach in the management of uterine fibroids in women who have completed their families. Sixty-two consecutive LSH were performed during this prospective study from March 2003 to March 2005 at Princess Royal University Hospital, Kent, UK. All study patients had menorrhagia resistant to at least one form of therapy, with a mean duration of symptoms of 3.5 years. In addition, four patients had previous myomectomy. The mean number of fibroids removed was 2.7. The mean weight of the uterus was 141.9 g. The mean operative time was 46.8 min, and the mean blood loss was 126.6 mL. The overall perioperative complication rate was 4.8% with no visceral injury, or return to theatre. At follow-up, all patients were satisfied with surgery. The study describes the first application of the PK and Lap Loop systems in LSH for the surgical management of uterine fibroids in women in whom fertility is not an issue, and its findings suggest that this minimally invasive technique is a safe, and valid alternative. Larger adequately-powered studies are however still required.

  5. The value of fetal ultrasonography and magnetic resonance imaging in the assessment of diaphragmatic hernias

    International Nuclear Information System (INIS)

    Amim, Bruno; Guerra, Fernando; Marchiori, Edson; Gasparetto, Emerson Leandro

    2008-01-01

    To demonstrate the relevance of ultrasonography and magnetic resonance imaging findings in the prenatal characterization and prognostic evaluation in cases of congenital diaphragmatic hernia. Materials And Methods: Fourteen pregnant women (mean gestational age = 28.7 weeks) who had undergone ultrasonography for suspicion of fetuses with congenital diaphragmatic hernia were assessed by means of magnetic resonance imaging on a 1.5 tesla equipment, following the standard protocol. Two radiologists evaluated the images and the findings were defined by consensus. Results: Twelve fetuses had left diaphragmatic hernia and two, right diaphragmatic hernia. Ultrasonography showed the fetal liver inside the thorax of five fetuses (three with left diaphragmatic hernia, and two with right diaphragmatic hernia) and magnetic resonance imaging in eight fetuses (six with left diaphragmatic hernia, and two with right diaphragmatic hernia). Stomach and small bowel loop herniation was observed in all of the fetuses with left diaphragmatic hernia (n = 12) at both magnetic resonance imaging and ultrasonography. Eight fetuses (seven with left diaphragmatic hernia and one with right diaphragmatic hernia) survived after surgical treatment. Conclusion: Ultrasonography and magnetic resonance imaging are complementary imaging methods in the evaluation of congenital diaphragmatic hernia. Magnetic resonance imaging is a helpful diagnostic method complementary to ultrasonography for evaluation of the fetal liver positioning, considering its relevance as a prognostic factor in cases of congenital diaphragmatic hernia. (author)

  6. Hydrodynamic study of syringomyelia by MRI and intraoperative ultrasonography

    International Nuclear Information System (INIS)

    Moritake, Kouzo; Takaya, Mikio; Minamikawa, Jun; Ishikawa, Masatsune; Kikuchi, Haruhiko; Minami, Shunsuke

    1989-01-01

    Syringomyelic cavities were studied with magnetic resonance imaging (MRI) in eleven patients with special reference to the hemodynamic contribution to the pathogenesis of syringomyelia. They were also studied intraoperatively with ultrasonography (USG) in five patients. Syrinx cavities combined with lumbosacral lipomyelomeningocele or with spinal stenosis did not present a flow-void phenomenon reflecting pulsatile movements of syrinx fluid. On serial MRI study in those the patients, enlargement of the syrinx cavity was not observed. Syrinx cavities occupying the caudal part of the spinal cord did not develop either. These cases were not treated surgically but followed conservatively. On the other hand, the flow-void sign in the syrinx cavities was present on MRI in patients who also had Chiari type I or type II malformations. They were treated with a syringo-subarachnoid shunt. In these cases, intraoperative USG disclosed marked fluctuation of syrinx cavity size synchronous with the motions of pulmonary ventilation. In all of them, clinical signs and symptoms improved postoperatively to various degrees. These results suggest that both the flow-void sign in the syrinx cavity on MRI and marked fluctaution of cavity size on intraoperative USG are indications for the shunt operation and support William's revised theory (1987). Fluctuation of cystic cavity size synchronous with ventilation suggests that venous pressure in the spinal subarachnoid space contributes to the pathogenesis of syringomyelic cavities. Further analysis of the fluctuation of cystic cavities by video monitoring will provide further information on the etiology and other clinical problems of syringomyelia. (author)

  7. Transcranial Doppler ultrasonography predicts cardiovascular events after TIA

    International Nuclear Information System (INIS)

    Holzer, Katrin; Sadikovic, Suwad; Esposito, Lorena; Bockelbrink, Angelina; Sander, Dirk; Hemmer, Bernhard; Poppert, Holger

    2009-01-01

    Transient ischemic attack (TIA) patients are at high vascular risk. We assessed the value of extracranial (ECD) and transcranial (TCD) Doppler and duplex ultrasonography to predict clinical outcome after TIA. 176 consecutive TIA patients admitted to the Stroke Unit were recruited in the study. All patients received diffusion-weighted imaging, standardized ECD and TCD. At a median follow-up of 27 months, new vascular events were recorded. 22 (13.8%) patients experienced an ischemic stroke or TIA, 5 (3.1%) a myocardial infarction or acute coronary syndrome, and 5 (3.1%) underwent arterial revascularization. ECD revealed extracranial ≥ 50% stenosis or occlusions in 34 (19.3%) patients, TCD showed intracranial stenosis in 15 (9.2%) and collateral flow patterns due to extracranial stenosis in 5 (3.1%) cases. Multivariate analysis identified these abnormal ECD and TCD findings as predictors of new cerebral ischemic events (ECD: hazard ratio (HR) 4.30, 95% confidence interval (CI) 1.75 to 10.57, P = 0.01; TCD: HR 4.73, 95% CI 1.86 to 12.04, P = 0.01). Abnormal TCD findings were also predictive of cardiovascular ischemic events (HR 18.51, 95% CI 3.49 to 98.24, P = 0.001). TIA patients with abnormal TCD findings are at high risk to develop further cerebral and cardiovascular ischemic events

  8. Ultrasonography and computed tomography in diffuse liver disease with cholestasis

    International Nuclear Information System (INIS)

    Partanen, K.; Pikkarainen, P.; Pasanen, P.; Alhava, E.; Soimakallio, S.; Kuopio Univ. Central Hospital; Kuopio Univ. Central Hospital

    1990-01-01

    Ultrasonography (US) and computed tomography (CT) were performed on respectively 67 and 42 (altogether 72) patients, for the assessment of intrahepatic cholestasis. The diagnostic ability to differentiate between malignant (17 patients) and benign (55 patients) liver disease was analyzed. Coarse echogenicity of the liver led to inconclusive results in differentiating between cirrhosis (2 out of 29 patients) and malignant infiltration (4 out of 15 patients) by US. Other benign liver diseases in 23 patients, including acute hepatitis, chronic active hepatitis, fatty liver, and liver congestion, were correctly interpreted as benign. CT correctly disclosed malignant liver disease in all cases. A false positive diagnosis of malignancy was encountered in 4 (out of 17) patients with decompensated hepatic cirrhosis because of non-homogeneous expansive areas on CT in 3 cases. The true cause was in 2 patients non-uniform fatty infiltration, and in one patient with acute hepatitis A, small hypodense lesions. Among cholestatic patients, decompensated cirrhosis and malignant liver infiltration could not always be differentiated on US or CT. (orig.)

  9. Ultrasonography of Skin Changes in Legs with Chronic Venous Disease.

    Science.gov (United States)

    Caggiati, A

    2016-10-01

    In daily practice, ultrasonography (US) is used only to designate the location and pattern of venous lesions. Skin US is not performed between routine venous investigations. Skin morphology is evaluated by the same probes used for routine Duplex evaluation of superficial veins. US findings from evident skin lesions are comparatively evaluated with those from the surrounding apparently normal skin and from the contralateral leg. Inflammation and dermal edema can be found in the apparently normal skin of C2 legs. Swollen legs show thickening of the subcutaneous layer as a result of diffuse soaking or anechoic cavities, with or without dermal edema. Chronic hypodermitis is characterized by inflammatory edema in initial phases, and by liposclerosis in advanced cases. Recrudescence of inflammation provokes focal rarefactions of the subcutaneous layer, possibly related to ulcer opening. In legs with venous disorders, sonography refines clinical evaluation of the skin and may reveal changes not highlighted by inspection. Some of these changes could require further investigation because they have not yet been explained or described. Skin sonography should improve knowledge of the natural history of skin changes, as well as contribute to a better grading of venous diseases severity In particular, US evidence of cutaneous and subcutaneous changes in C2 legs should be considered to stratify the treatment in C2 legs, by identifying those in which varicose veins are not simply a cosmetic problem. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Deep venous thrombus characterization: ultrasonography, elastography and scattering operator

    Directory of Open Access Journals (Sweden)

    Thibaud Berthomier

    2017-04-01

    Full Text Available A thrombus or a blood clot is the result of blood coagulation which is a natural process to prevent bleeding. An inappropriate formation of a thrombus in a deep vein is known as Deep Venous Thrombosis (DVT. The main complication of a DVT is a Pulmonary Embolism (PE which occurs when a thrombus breaks loose and travels to the lungs. DVT, PE, or both are also known as Venous thromboembolism (VTE. It affects an estimated 300,000–600,000 Individuals just in the United States per year and can cause considerable morbidity and mortality. This multifactorial disease related to advanced age, immobility, surgery or obesity is an important public health issue. Our project is looking to link the VTE epidemiology (risk factors, patient history, PE to the thrombus structure. To reach our goals, we are collecting ultrasonography (echogenicity and elastography (stiffness of human thrombus. This manuscript describes our approach to create and preprocess a database using Toshiba Aplio 500. Our approaches to characterize the thrombus structure with ultrasound images are also described. The feature extraction is made with the scattering operator. Obtained features are then reduced using Principal Component Analysis and are analyzed to evaluate our approach.

  11. Ultrasonography findings and tumour quantification in patients with pseudomyxoma peritonei

    International Nuclear Information System (INIS)

    Krause, J.; Bergman, A.; Graf, W.; Nilsson, A.; Mahteme, H.

    2012-01-01

    Pseudomyxoma peritonei (PMP) is a disease with various clinical presentations and the diagnostic value of ultrasonography (US) is under investigated. The purpose of this study was to identify the most common US finding in PMP and to investigate US sensitivity, specificity, positive and negative predictive value in quantifying tumour burden in different abdomino-pelvic regions in PMP patients. Between February 2006 and December 2008, 54 patients were treated with cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) due to PMP. The results from preoperative US examination with and without intravenously administrated contrast (SonoVue) were compared to surgical findings. The mean US peritoneal cancer index (PCI) was 6 (range 0–25) and the surgical PCI was 18 (range 3–27) p < 0.0001. The histo-pathological subtypes did not influence the US findings. Ascites, bowel loops adhesions and omental cake were mostly visualised correctly by US. The sensitivity of US in quantification of tumour nodules was 91.5% (range 74–100%) and specificity was 33.8% (range 18–55%). The positive predictive value of US examination in PMP was 22% (range 11–44%) and the negative predictive value was 93% (range 77–100%). US can detect the most common PMP findings (ascites and omental cake). The sensitivity of US to quantify PMP tumour burden in different abdominio-pelvic region was relatively high, however, this imaging tool had low specificity.

  12. Availability of ultrasonography in health examination of atomic bomb survivors

    International Nuclear Information System (INIS)

    Kato, Masafumi; Mito, Kazuyo; Ishibashi, Shinzo; Takayama, Sadamatsu; Ito, Chikako

    1989-01-01

    A total of 1424 A-bomb survivors, consisting of 596 men and 827 women, participated in the health screening during the period from August 1985 through March 1988. Abnormal findings of ultrasonography were observed in 64% for men and 53% for women. According to age groups, the incidence of abnormal findings tended to increase with aging in men. In women, it was independent of aging. The most common abnormal finding was billiary calculus (13%), followed by renal cyst, splenomegaly, hepatomegaly, and liver disturbance. Suspected hepatic tumor, hepatomegaly, liver disturbance, fatty liver, and liver cirrhosis were more frequent in men than women. The incidence of billiary or gallbladder calculus was significantly higher in women than men. Among 56 survivors (13%) with suspected malignancy, it was confirmed in 25 survivors (19 with primary or metastatic liver carcinoma, 3 with renal cell carcinoma, 2 with cholangiocarcinoma, and one with pancreatic carcinoma). Of 9 hepatoma patients, 8 had an increased alpha-fetoprotein. Hematologic findings were normal in all of the patients with renal cell carcinoma. (N.K.)

  13. Fetal central nervous system anomalies: fast MRI vs ultrasonography

    International Nuclear Information System (INIS)

    Yang Wenzhong; Xia Liming; Yang Minjie; Feng Dingyi; Hu Junwu; Zou Mingli; Wang Chengyuan; Chen Xinlin; Yang Xiaohong

    2006-01-01

    Objective: To evaluate the ability of fast MRI to detect fetal central nervous system (CNS) anomalies and to compare its performance with that of prenatal ultrasonography (US). Methods Forty-eight pregnant women were detected by conventional prenatal US and MRI. Twenty-two fetuses with CNS anomalies were conformed by autopsy and follow-up. The MR and US appearances of fetal CNS structure were compared to each other and to that of autopsy. Results: A total of 26 CNS anomalies were identified by autopsy (n=17) and follow-up (n=9) including anencephaly (n=6), rachischisis (n=2), encephalocele (n=3), congenital hydrocephalus (n=7), alobar holoprosencephaly (n=1), porencephalia (n=3), arachnoid cyst (n=2) and choroids plexus cyst (n=2). US diagnosed 24 CNS anomalies, the correct diagnostic rate was 92.3%, the false-positive rate was 3.8%, the missed-diagnostic rate was 3.8%. MRI diagnosed 23 CNS anomalies, the correct-diagnostic rate was 88.5%, the false-positive rate was 3.8% ,the missed-diagnostic rate was 7.7%. There was no difference between US and MRI (P>0.05), but MRI have larger FOV, higher tissues resolution, and can demonstrate gray-white matter in detail. Conclusions: MR imaging has a similar sensitivity to that of US in the detection of fetal CNS anomalies. (authors)

  14. Ultrasonography and arthrography in rotator cuff lesions: algorithmic approach

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eui Jong; Ryu, Kyung Nam; Lee, Sun Wha; Lim, Jae Hoon; Rhee, Yong Girl [Kyung Hee University Hospital, Seoul (Korea, Republic of); Yu, Pil Mun [Dankuk University College of Medicine, Chenona (Korea, Republic of)

    1992-11-15

    Twenty-six patients with chief complaint of shoulder pain who underwent both ultrasonographic examination and arthrography of the shoulder were analyzed. Ten out of 12 cases with clinical impression of frozen shoulder, showed normal findings on the ultrasonographic examination of the shoulder. Among these ten cases, nine cases showed adhesive capsulitis and one case showed rotator cuff tear on arthrography. Among six cases with the clinical impression of rotator cuff tear, five cases showed rotator cuff tear and one case showed combined calcific tendinitis and adhesive capsulitis on ultrasonographic examination. In arthrography, four cases of rotator cuff tear, one case of calcific tendinitis and biceps tendinitis and one case of normal finding were diagnosed. For the remaining eight cases in the ultrasonographic examination, normal finding or biceps tendinitis were found and for the remaining of the cases in arthrography adhesive capsulitis were found. With the above results, we recommend that the shoulder ultrasonography as the first line diagnostic modality for a patient with chief complaint of shoulder pain.

  15. Ultrasonography and arthrography in rotator cuff lesions: algorithmic approach

    International Nuclear Information System (INIS)

    Kim, Eui Jong; Ryu, Kyung Nam; Lee, Sun Wha; Lim, Jae Hoon; Rhee, Yong Girl; Yu, Pil Mun

    1992-01-01

    Twenty-six patients with chief complaint of shoulder pain who underwent both ultrasonographic examination and arthrography of the shoulder were analyzed. Ten out of 12 cases with clinical impression of frozen shoulder, showed normal findings on the ultrasonographic examination of the shoulder. Among these ten cases, nine cases showed adhesive capsulitis and one case showed rotator cuff tear on arthrography. Among six cases with the clinical impression of rotator cuff tear, five cases showed rotator cuff tear and one case showed combined calcific tendinitis and adhesive capsulitis on ultrasonographic examination. In arthrography, four cases of rotator cuff tear, one case of calcific tendinitis and biceps tendinitis and one case of normal finding were diagnosed. For the remaining eight cases in the ultrasonographic examination, normal finding or biceps tendinitis were found and for the remaining of the cases in arthrography adhesive capsulitis were found. With the above results, we recommend that the shoulder ultrasonography as the first line diagnostic modality for a patient with chief complaint of shoulder pain

  16. Musculoskeletal ultrasonography delineates ankle symptoms in rheumatoid arthritis.

    Science.gov (United States)

    Toyota, Yukihiro; Tamura, Maasa; Kirino, Yohei; Sugiyama, Yumiko; Tsuchida, Naomi; Kunishita, Yosuke; Kishimoto, Daiga; Kamiyama, Reikou; Miura, Yasushi; Minegishi, Kaoru; Yoshimi, Ryusuke; Ueda, Atsuhisa; Nakajima, Hideaki

    2017-05-01

    To clarify the use of musculoskeletal ultrasonography (US) of ankle joints in rheumatoid arthritis (RA). Consecutive RA patients with or without ankle symptoms participated in the study. The US, clinical examination (CE), and patients' visual analog scale for pain (pVAS) for ankles were assessed. Prevalence of tibiotalar joint synovitis and tenosynovitis were assessed by grayscale (GS) and power Doppler (PD) US using a semi-quantitative grading (0-3). The positive US and CE findings were defined as GS score ≥2 and/or PD score ≥1, and joint swelling and/or tenderness, respectively. Multivariate analysis with the generalized linear mixed model was performed by assigning ankle pVAS as a dependent variable. Among a total of 120 ankles from 60 RA patients, positive ankle US findings were found in 21 (35.0%) patients. The concordance rate of CE and US was moderate (kappa 0.57). Of the 88 CE negative ankles, US detected positive findings in 9 (10.2%) joints. Multivariate analysis revealed that ankle US, clinical disease activity index, and foot Health Assessment Questionnaire, but not CE, was independently associated with ankle pVAS. US examination is useful to illustrate RA ankle involvement, especially for patients who complain ankle pain but lack CE findings.

  17. Characterisation of focal liver lesions with contrast enhanced ultrasonography

    International Nuclear Information System (INIS)

    Dietrich, Christoph F.

    2004-01-01

    Ultrasound contrast agents (USCA) have improved the detection rate of liver tumours in recent years. Conventional ultrasound has been reported to be relatively unreliable in the characterisation of liver tumours. SonoVue [reg] (Bracco Imaging Spa) has been shown to be particularly advantageous in the differentiation of benign and malignant liver tumours and, therefore, possibly represents a new cost-effective competitive alternative to other liver imaging modalities (e.g. computed tomography and magnetic resonance imaging), thus allowing these important technologies to be available for other indications (e.g. brain, thorax). More detailed and specific liver tumour characterisation is possible in about 80% of liver tumours due to typical vascularity and perfusion patterns. The role of USCA for better characterisation, which is possible through the analysis of flow characteristics in real time, places a particular emphasis on agent use. Contrast enhanced real-time imaging techniques with SonoVue [reg] allow real-time analysis of tumour perfusion in patients with liver lesions. Liver tumours known to be hyperperfused in the arterial phase (e.g. focal nodular hyperplasia, hepatocellular adenoma and carcinoma, and hyperperfused metastases) can be better detected and characterised. Hypoperfused tumours (e.g. liver metastases of the gastrointestinal tract) can be recognised in the portal venous phase as less perfused 'black spots'. In this article we discuss liver tumour characterisation by contrast enhanced ultrasonography

  18. Utility of Ultrasonography for Urinary Tract Infections of Infants

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Chul Ho; Kim, Yun Jeong [Dongnam Health Univ., Seoul (Korea, Republic of)

    2009-06-15

    In this study, we investigated utility of ultrasonography for urinary tract infections of infants. The results of the research is as follows : 1. The number of infants under one year old was 100 out of 122 infants who were diagnosed as a unitary infection. The ratio of males to females was 1.7 : 1. Seventy-seven infants who underwent three kinds of radiologic examinations such as kidney sonography (51%), {sup 99m}TC DMSA-scan (42%), and VCUG (22%). 2. In comparison of correlation between kidney sonography and VCUG, the sensitivity of kidney sonography was 82% while the specificity of kidney sonography was 58%. In comparison of correlation between kidney sonography and {sup 99m}TC DMSA-scan, the sensitivity of kidney sonography was 66% while the specificity of kidney sonography was 67%. 3. Utility of kidney sonography showed the highest efficiency when we considered pain, discomfort, a sense of shame, psychological stress when infants may undergo at the examination, side-effect of a contrast agent after the examination, and complication of exposure to radiation.

  19. The usefulness of transvaginal ultrasonography and MRI in endometrial carcinoma

    International Nuclear Information System (INIS)

    Yoshihara, Eisuke

    1992-01-01

    Between October 1988 and March 1991, 29 patients with endometrial carcinoma had both transvaginal ultrasonography (TVUS) and magnetic resonance imaging (MRI) performed following hysterectomy at the Department of Gynecology and Obstetrics, Okayama University Medical School. The findings were compared with the pathological findings to determine the usefulness of each method. The sensitivity of detecting myometrial invasion was 100% by TVUS and 96% by MRI. The accuracy was 86% by each method. The depth of myometrial invasion was classified into 3 degrees [no myometrial invasion, superficial invasion (≤1/2), deep invasion (>1/2)]. The correct diagnostic rate was 86% by TVUS and MRI. The minimum width and the minimum/maximum width ratio of the intact myometrium obtained by each method in the pathological deep invasion group were significantly lower than those obtained in the other two groups (p<0.01). The sensitivity, the accuracy and the specificity for detecting cervical invasion were 89%, 93% and 95% by both methods. There was no difference between TVUS and MRI for diagnosing myometrial and cervical invasion of endometrial carcinoma. (author)

  20. Contrast-Enhanced Endoscopic Ultrasonography for Pancreatic Tumors

    Directory of Open Access Journals (Sweden)

    Yasunobu Yamashita

    2015-01-01

    Full Text Available Objectives. To investigate the usefulness of contrast-enhanced endoscopic ultrasonography (CE-EUS for histological differentiation of pancreatic tumors. Methods. CE-EUS was performed for consecutive patients having a pancreatic solid lesion, and tumors were classified into three vascular patterns (hypervascular, isovascular, and hypovascular at two time phases (early-phase and late-phase. Correlation between vascular patterns and histopathology of resected pancreatic cancer (PC tissues was ascertained. Results. The final diagnoses of 147 examined tumors were PC (n=109, inflammatory mass (n=11, autoimmune pancreatitis (n=9, neuroendocrine tumor (n=8, and others (n=10. In late-phase images, 104 of 109 PCs had the hypovascular pattern, for a diagnostic sensitivity and specificity of 94% and 71%, respectively. Of 28 resected PCs, 10 had isovascular, and 18 hypovascular, patterns on the early-phase image. Early-phase isovascular PCs were more likely to be differentiated than were early-phase hypovascular PCs (6 well and 4 moderately differentiated versus 3 well, 14 moderately, and 1 poorly differentiated, P=0.028. Immunostaining revealed that hypovascular areas of early-phase images reflected heterogeneous tumor cells with fibrous tissue, necrosis, and few vessels. Conclusion. CE-EUS could be useful for distinguishing PC from other solid pancreatic lesions and for histological differentiation of PCs.

  1. Clinical diagnostic potentials of thyroid ultrasonography and scintigraphy; An evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Torizuka, Tatsuo; Kasagi, Kanji; Hatabu, Hiroto; Misaki, Takashi; Iida, Yasuhiro; Konishi, Junji (Kyoto Univ. (Japan). Hospital); Endo, Keigo

    1993-06-01

    This prospective study was designed to evaluate the potential contributions of high resolution ultrasonography (US) and Tc-99m scintigraphy in the routine diagnosis of thyroid disease. The diagnostic impacts of US and Tc-99m scintigraphy results in 177 patients visiting our thyroid clinic were assessed and scored according to the following criteria: when the information provided by either test supported, confirmed or changed the initial clinical diagnosis, they received scores of 2, 3 and 4 respectively, while score 1 was given when the test itself was useless for the differential diagnosis. US identified focal lesions that both palpation and scintigraphy had failed to detect in 14 (12.1%) of 116 patients with diffuse thyroid diseases, suggesting the necessity of Hashimoto's thyroiditis, adenoma, adenocarcinoma and adenomatous goiter, and vice versa in the diagnosis of hyperthyroid and euthyroid Graves's diseases. Thus, the advantages of US over scintigraphy for morphological evaluation were confirmed. US was particularly useful for the differential diagnosis of adenomatous goiter from Hashimoto's thyroiditis or a single nodular disease. In contrast, scintigraphy gave functional images, being especially helpful for the differential diagnosis of thyrotoxicosis. (author).

  2. Utility of Ultrasonography for Urinary Tract Infections of Infants

    International Nuclear Information System (INIS)

    Yoon, Chul Ho; Kim, Yun Jeong

    2009-01-01

    In this study, we investigated utility of ultrasonography for urinary tract infections of infants. The results of the research is as follows : 1. The number of infants under one year old was 100 out of 122 infants who were diagnosed as a unitary infection. The ratio of males to females was 1.7 : 1. Seventy-seven infants who underwent three kinds of radiologic examinations such as kidney sonography (51%), 99m TC DMSA-scan (42%), and VCUG (22%). 2. In comparison of correlation between kidney sonography and VCUG, the sensitivity of kidney sonography was 82% while the specificity of kidney sonography was 58%. In comparison of correlation between kidney sonography and 99m TC DMSA-scan, the sensitivity of kidney sonography was 66% while the specificity of kidney sonography was 67%. 3. Utility of kidney sonography showed the highest efficiency when we considered pain, discomfort, a sense of shame, psychological stress when infants may undergo at the examination, side-effect of a contrast agent after the examination, and complication of exposure to radiation.

  3. Imperforate Anus: Determination of Type Using Transperineal Ultrasonography

    International Nuclear Information System (INIS)

    Choi, Young Hun; Kim, In One; Cheon, Jung Eun; Kim, Woo Sun; Yeon, Kyung Mo

    2009-01-01

    This study was designed to assess the usefulness of transperineal ultrasonography (US) for the determination of imperforate anus (IA) type. From January 2000 to December 2004, 46 of 193 patients with an IA underwent transperineal US prior to corrective surgery. Sonographic findings were reviewed to identify the presence of internal fistulas and to determine 'distal rectal pouch to perineum (P-P)' distances. IA types were determined based on the sonographic findings, and the diagnostic accuracy of transperineal US was evaluated based on surgical findings. Of the 46 patients, 17 patients were surgically confirmed as having a high-type IA, three patients were confirmed as having an intermediate-type IA and 26 patients were confirmed as having a low-type IA. The IA type was correctly diagnosed by the use of transperineal US in 39 of the 46 patients (85%). In 14 of the 17 patients with a high-type IA, internal fistulas were correctly identified. All cases with a P-P distance > 16 mm were high-type IAs and all cases with a P-P distance < 5 mm were low-type IAs. Transperineal US is a good diagnostic modality for the identification of internal fistulas in cases of high-type IA and for defining the IA level

  4. Value of ultrasonography in the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Sohn, Seok Ho; Jung, Kun Sik; Kim, Jung Sik; Woo, Seong Ku; Chung, Ki Yong; Kim, Hee Jin

    1993-01-01

    During a 12-month period high-resolution, real-time ultrasonography (US) with graded compression was performed on 268 consecutive patients with clinically suspected acute appendicitis and its complications. US visualization of a fluid-filled, non-compressed appendix or a decompressed, thick-walled appendix was the primary criterion for a diagnosis of acute appendicitis. The sonographic findings were correlated with surgical-pathologic outcome in 92 cases and with the findings of clinical follow-ups in the remainder. US was found to be accurate in the diagnosis of acute appendicitis and its complication with a sensitivity of 93.3%, a specificity of 98.9%, and an accuracy of 97%. The predictive value of a positive test was 97.7%; that of a negative test was 96.7%. There were two false-positive examinations in patients with a thick-walled appendix or periapperdiceal abscess, which were surgically confirmed as appendiceal adenocarcinoma and perforated cecal diverticulitis respectively. There were six false-negative examinations in patients with a sonographically no-visible appendix, which were confirmed surgically as acute appendicitis (n=5) and perforated appendicitis (n=1). Our results show that high-resolution, real-time US is an accurate imaging modality in the diagnosis of acute appendicitis and the evaluation of its complications

  5. Double contrast-enhanced ultrasonography in the detection of periampullary cancer: Comparison with B-mode ultrasonography and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ting [Department of Medical Image Center, Zhujiang Hospital, Southern Medical University, Guangzhou (China); Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Su, Zhong-zhen; Wang, Ping; Wu, Tao [Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Tang, Wen [Department of Radiology, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Xu, Er-jiao; Ju, Jin-xiu [Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Quan, Xian-yue, E-mail: quanxianyue2014@163.com [Department of Medical Image Center, Zhujiang Hospital, Southern Medical University, Guangzhou (China); Zheng, Rong-qin, E-mail: zhengrq@mail.sysu.edu.cn [Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China)

    2016-11-15

    Purpose: To investigate the value of double contrast-enhanced ultrasonography (DCEUS) in the detection of periampullary cancer. Materials and methods: Ninety-nine patients with surgery or biopsy-proven periampullary cancer who underwent both DCEUS and magnetic resonance imaging (MRI) examinations before operation were enrolled in our study. DCEUS in which intravenous microbubbles were used in combination with oral contrast agent and MRI were performed preoperatively to make a detection diagnosis of periampullary cancer. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of DCEUS, B-mode ultrasonography (BUS) and MRI were calculated and compared. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy of BUS, DCEUS and MRI in the detection. Stratified analyses were performed for different pathological types and different sizes of periampullary lesions. The inter- and intra-observer reliability of DCEUS for cancer detection was also investigated. Result: There were no significant differences in sensitivity, specificity, PPV, NPV or accuracy between DCEUS and MRI (all P > 0.05). ROC analysis showed that the accuracy of DCEUS or MRI was higher than that of BUS (P < 0.001), while no significant differences were noted in the accuracy between DCEUS and MR. In the 76 cases of periampullary cancer, DCEUS appeared to be superior to BUS for ampullary carcinoma, duodenum carcinoma and for lesions with an average diameter of less than 3 cm. DCEUS appeared equal to BUS in other groups. No significant differences were noted between DCEUS and MRI in the stratified analysis. A considerably well agreement between DCEUS and MRI was obtained using Kappa analysis (k = 0.649, P < 0.001). The intra- and inter-observer reproducibility were both good for detection of periampullary cancer by DCEUS, with a Kappa values of 0.783 (P < 0.01) and 0.732 (P < 0.01), respectively. Conclusion: DCEUS provides an

  6. Ultrasonography - A diagnostic modality for oral and maxillofacial diseases

    Directory of Open Access Journals (Sweden)

    Priya Shirish Joshi

    2014-01-01

    Full Text Available Background: Many diseases present themselves in oral and maxillofacial regions and various modalities may be applied for their diagnosis, including intraoral and panoramic radiography, ultrasonography (USG, computer tomography, magnetic resonance imaging, and nuclear medicine methods such as positron emission tomography. Of these modalities, USG is easy to-use for the detection of non-invasive and soft tissue related diseases in oral and maxillofacial regions. USG plays an important role in analyzing normal and abnormal structures. In particular, in oral and maxillofacial regions, the USG may be clinically applied to evaluate lymph nodes, subcutaneous, and oral cavity-related diseases. Aims: The aim was to correlate the findings of USG and histopathology for the diagnosis of oral and maxillofacial pathology and to evaluate whether USG can be used as an adjunct in diagnosing oral and maxillofacial pathology. Materials and Methods: A total of 10 clinically diagnosed patients with intraoral cancerous growths, swellings in maxillary and neck region were included in this study. Incision biopsy was obtained for confirming provisional clinical diagnosis. The selected cases were advised USG. All patients were then posted either for hemi-glossectomy, hemi-mandibulectomy, and partial maxillectomy with or without radical neck dissection. Statistical Analysis: Student′s t-test and coefficient of correlation was used to statistically analyze significant relationship of both the methods. Result: In all 10 cases, USG correlated well with histopathology findings, it could also delineate tumor extent and measure tumor thickness. Conclusion: USG is an excellent method for the diagnosis of soft tissue lesions and can be used as an adjunct in diagnosing oral and maxillofacial pathology.

  7. Does Prebiopsy, Nonsterile Ultrasonography Gel Affect Biopsy-Site Asepsis?

    International Nuclear Information System (INIS)

    Gurel, Kamil; Karabay, Oguz; Gurel, Safiye; Hildebolt, Charles

    2008-01-01

    Purpose. The purpose of this study was to determine the extent to which the use of nonsterile gel, prior to antiseptic procedures in ultrasonography (US)-guided percutaneous biopsies, results in contamination of the biopsy site. Materials and Methods. Patients referred for US-guided percutaneous biopsies were included in this study. Transmission material used for US evaluation before biopsy-site antiseptic procedures were performed was either nonsterile gel or sterile saline. Patients were randomly assigned to two groups: nonsterile gel (n = 30) and sterile saline (n = 30). Before the transmission material was used and after antiseptic procedures were performed, microbial swabs of a 10-cm 2 -diameter area were obtained at the biopsy site. Swabs were also obtained from the gel, saline, and povidine-iodine. Inoculated specimen plates were incubated at 37 o C under aerobic conditions, and the numbers of colony-forming units recorded. Nominal logistic regression analysis was used to calculate the odds of postantisepsis bacterial growth (after antiseptic procedures were performed) based on group, gender, coincidental disease (diabetes, chronic renal failure, and malignancy), biopsy-site location (head and neck or breast and abdomen), and local factors (skin fold, skin tag, and hair). Results. The following odds ratios (adjusted for the other variables) and their 95% confidence intervals were calculated: (1) group (2.9 [0.8-11.1]; p = 0.10); (2) gender (1.2 [0.3-5.2]; p = 0.78); (3) coincidental disease (7.6 [0.9-166.7]; p = 0.09); (4) biopsy site location (6.2 [1.4-31.3]; p = 0.02); and (5) local factors (7.0 [1.6-36.0]; p = 0.01). No bacterial growth occurred with swabs obtained from gel, povidine-iodine, or saline. Conclusion. We conclude that nonsterile gel used prior to percutaneous biopsy does not affect biopsy-site asepsis

  8. Evaluation of real time ultrasonography of the normal pancreas

    International Nuclear Information System (INIS)

    Kim, H. K.; Ko, Y. T.; Kim, S. Y.; Ahn, C. Y.

    1981-01-01

    91 cases who were free of pancreatic disease and the related conditions, were studied by high resolution and wide field real time ultrasonographic scanner with 3.5 MHz linear array electronically focusing transducers. The pancreatic examination method and the anatomic structures in and around the pancreas were investigated, and the normal pancreatic findings by real time ultrasonography were as follows: 1. Among all 91 cases, 44 cases were male and 47 cases female, and the frequent age groups were the 4th to the sixth decade. 2. The pancreatic images were obtained in 86% and the good images in 65%. 3. The shapes of pancreas were sausage (40%), dumb-bell (34%), tadpole (9%), and club (17%). 4. Pancreatic size was 1.56 ± 0.37, 2.4, 0.8 cm (Mean ± SD, Max., Min.) in head, 1.32 ± 0.29, 2.0, 0.8 cm in isthmus, and 1.62 ± 0.31, 2.4, 1.0 cm in tail. 5. The successful rate of pancreatic duct visualization was 46%. The shapes of pancreatic duct were linear (22%), tramline (16%), and tubular (8%). 6. The pancreatic echogenecity is greater than that of the liver in 68%, and equivalent to that of the liver in 32%, and no normal pancreas displayed less echogenecity than the liver. 7. Pancreatic echogenecity is lesser than that of adjacent soft tissue in 79% and equivalent to that of adjacent soft tissue in 21%. 8. The pancreatic echogenecity is homogenous in 79%. 9. The pancreatic margin is smooth in 62%, undulated in 11%, and ill defined in 27%

  9. Quantitative Assessment of Hepatic Fibrosis by Contrast-enhanced Ultrasonography

    Institute of Scientific and Technical Information of China (English)

    Ming-bo Zhang; En-ze Qu; Ji-Bin Liu; Jin-rui Wang

    2011-01-01

    Objective To explore the contrast-enhanced ultrasonographic features for quantitative assessment of hepatic fibrosis.Methods 86 patients with chronic viral hepatitis B were enrolled in this study from March 2007 to August 2009.The patients were classified into 5 groups (S0-S4) according to fibrosis stage evaluated with ultrasound guided liver biopsy.New contrast-enhanced ultrasonography (CEUS) features including area under the time-intensity curve (TIC) of portal venous phase/hepatic arterial phase (Qp/Qa) and intensity of portal venons phase/hepatic arterial phase (Ip/Ia) were used to detect the blood supply ratio (portal vein/hepatic artery) in each group.Arrival time of portal vein trunk (Tp) and decreasing rate of TIC (β) were also analyzed.Results Qp/Qa and Ip/Ia decreased from So to S4,while Tp and β increased These 4 features were significantly correlated with the degree of fibrosis (P<0.001) and were significantly different among the five groups (P<0.001).Sensitivity and specificity of Ip/Ia were 80% and 86% for groups ≥S1,75% and 86% for groups ≥ S2,71% and 84% for groups ≥ S3,and 76% and 80% for group S4,respectively.Sensitivity and specificity of Qp/Qa were 70% and 88% for groups ≥ S1,80% and 76% for groups ≥ S2,74% and 70% for groups ≥ S3,and 81% and 95% for group S4,respectively.Conclusion Ip/Ia and Qp/Qa could be adopted as reliable,non-invasive features for quantitative assessment of hepatic fibrosis.

  10. Evaluation of peripheral enthesitis in spondyloarthritis: Ultrasonography versus clinical examination

    Directory of Open Access Journals (Sweden)

    Anupam Wakhlu

    2017-01-01

    Full Text Available Background: Enthesitis is an important feature of spondyloarthritis but may often be subclinical. Data is sparse, especially from India, on the ultrasonography (USG detection of enthesitis in these patients. The present study aimed to find the prevalence and pattern of entheseal involvement assessed clinically and by USG. Methods: Fifty-two spondyloarthritis, 26 rheumatoid arthritis, and 26 healthy controls were evaluated for enthesitis by clinical examination and by USG using 2014 OMERACT consensus group definitions at bilateral Achilles insertion on the calcaneus, plantar fascia attachment on the calcaneus, quadriceps tendon insertion on the patella, patellar tendon origin from the inferior pole of the patella, and patellar tendon insertion on the tibial tuberosity. At least one ultrasonographic finding at any of the above sites was considered positive for enthesitis. Results: The number of entheseal sites screened in spondyloarthritis patients was 520 and 260 each in rheumatoid arthritis and healthy controls. USG (sensitivity - 94.2% was better in detecting enthesitis than clinical examination (sensitivity - 69.2%. Clinical examination was highly specific (100% compared to USG (55.7% in differentiating from rheumatoid arthritis and healthy controls. USG alone without clinical findings was positive at 23.8% of sites while clinical examination alone without USG findings was positive at 5.2% of sites. Frequency of enthesitis in rheumatoid arthritis was not more than healthy controls (6.1% vs. 8.1%, respectively and was much less than spondyloarthritis (34%. Conclusion: USG is a good screening tool for detection of enthesitis but cannot replace clinical examination completely.

  11. Incidence of bacteremia in cirrhotic patients undergoing upper endoscopic ultrasonography.

    Science.gov (United States)

    Fernández-Esparrach, Gloria; Sendino, Oriol; Araujo, Isis; Pellisé, Maria; Almela, Manel; González-Suárez, Begoña; López-Cerón, María; Córdova, Henry; Sanabria, Erwin; Uchima, Hugo; Llach, Josep; Ginès, Àngels

    2014-01-01

    The incidence of bacteremia after endoscopic ultrasonography (EUS) or EUS-guided fine-needle aspiration (EUS-FNA) is between 0% and 4%, but there are no data on this topic in cirrhotic patients. To prospectively assess the incidence of bacteremia in cirrhotic patients undergoing EUS and EUS-FNA. We enrolled 41 cirrhotic patients. Of these, 16 (39%) also underwent EUS-FNA. Blood cultures were obtained before and at 5 and 30 min after the procedure. When EUS-FNA was used, an extra blood culture was obtained after the conclusion of radial EUS and before the introduction of the sectorial echoendoscope. All patients were clinically followed up for 7 days for signs of infection. Blood cultures were positive in 16 patients. In 10 patients, blood cultures grew coagulase-negative Staphylococcus, Corynebacterium species, Propionibacterium species or Acinetobacterium Lwoffii, which were considered contaminants (contamination rate 9.8%, 95% CI: 5.7-16%). The remaining 6 patients had true positive blood cultures and were considered to have had true bacteremia (15%, 95% CI: 4-26%). Blood cultures were positive after diagnostic EUS in five patients but were positive after EUS-FNA in only one patient. Thus, the frequency of bacteremia after EUS and EUS-FNA was 12% and 6%, respectively (95% CI: 2-22% and 0.2-30%, respectively). Only one of the patients who developed bacteremia after EUS had a self-limiting fever with no other signs of infection. Asymptomatic Gram-positive bacteremia developed in cirrhotic patients after EUS and EUS-FNA at a rate higher than in non-cirrhotic patients. However, this finding was not associated with any clinically significant infections. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.

  12. Accuracy of endoscopic ultrasonography for diagnosing ulcerative early gastric cancers

    Science.gov (United States)

    Park, Jin-Seok; Kim, Hyungkil; Bang, Byongwook; Kwon, Kyesook; Shin, Youngwoon

    2016-01-01

    Abstract Although endoscopic ultrasonography (EUS) is the first-choice imaging modality for predicting the invasion depth of early gastric cancer (EGC), the prediction accuracy of EUS is significantly decreased when EGC is combined with ulceration. The aim of present study was to compare the accuracy of EUS and conventional endoscopy (CE) for determining the depth of EGC. In addition, the various clinic-pathologic factors affecting the diagnostic accuracy of EUS, with a particular focus on endoscopic ulcer shapes, were evaluated. We retrospectively reviewed data from 236 consecutive patients with ulcerative EGC. All patients underwent EUS for estimating tumor invasion depth, followed by either curative surgery or endoscopic treatment. The diagnostic accuracy of EUS and CE was evaluated by comparing the final histologic result of resected specimen. The correlation between accuracy of EUS and characteristics of EGC (tumor size, histology, location in stomach, tumor invasion depth, and endoscopic ulcer shapes) was analyzed. Endoscopic ulcer shapes were classified into 3 groups: definite ulcer, superficial ulcer, and ill-defined ulcer. The overall accuracy of EUS and CE for predicting the invasion depth in ulcerative EGC was 68.6% and 55.5%, respectively. Of the 236 patients, 36 patients were classified as definite ulcers, 98 were superficial ulcers, and 102 were ill-defined ulcers, In univariate analysis, EUS accuracy was associated with invasion depth (P = 0.023), tumor size (P = 0.034), and endoscopic ulcer shapes (P = 0.001). In multivariate analysis, there is a significant association between superficial ulcer in CE and EUS accuracy (odds ratio: 2.977; 95% confidence interval: 1.255–7.064; P = 0.013). The accuracy of EUS for determining tumor invasion depth in ulcerative EGC was superior to that of CE. In addition, ulcer shape was an important factor that affected EUS accuracy. PMID:27472672

  13. Prediction of cerebrovascular reserve by the MRI and doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hui Joong; Kim, Yong Sun [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2005-07-15

    We investigated acute stroke patterns on diffusion weighted images and with doppler ultrasonography studies of ICA and MCA steno-occlusive diseases in order to predict the cerbrovascular reserve (CVR), as was measured by acetazolamide (ACZ)-challenged Tc-99m ECD brain perfusion SPECT. A retrospective analysis was performed of 76 patients who underwent MRI/MRA, ACZ-challenged Tc-99m ECD brain perfusion SPECT, and carotid and vertebral artery Doppler sonography. After dividing these patients into four groups-MCA and ICA ateno-occlusions, we analyzed the relationship between the CVR and topologic MR patterns and the flow volume, as was measured by Doppler sonography. The CVRs were preserved in 26 of 76 patients. The CVRs were impaired in those cases of occlusion that were detected on MRA and also by the pattern of the territorial involvement on the diffusion weighted image ({rho} < 0.05, x{sup 2} test). Yet in cases of preserved CVRs, the flow volume of the contralateral ICA, the anterior circulation, and the total cerebral flow volume were increased, as was checked by Doppler sonography ({rho} < 0.05, t-test). As calculated by logistic regression analysis, the accuracy for predicting the preserved CVR by using the statistically significant variables was 78%. We believe that the MRI-SPECT correlation study was helpful for understanding the hemodynamics and topographic patterns of ischemia in patients with ICA and MCA steno-occlusive disease, and that the flow volume measurement, which was done by using duplex US, was useful for predicting the CVR.

  14. Comparison of the capsular width measured on ultrasonography and MR image of the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae Wan; Yoo, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Dankook University, Seoul (Korea, Republic of)

    2006-03-15

    To evaluate the reliability and clinical usefulness of ultrasonography in the temporomandibular joint(TMJ). Parasagittal and paracoronal 1.5 T MR images and 7.5 MHz ultrasonography of 40 TMJs in 20 asymptomatic volunteers were obtained. Disc position using MR imaging was evaluated and the distance between the lateral surface of mandibular condyle and the articular capsule using MR image and ultrasonography of 27 TMJs with normal disc position was measured and compared. Intraobserver and interobserver measurements reliability was evaluated by using interclass correlation coefficients (ICC) and measurement error. Also, the distance measured on ultrasonography was compared, according to mouth position and disc position. The normal disc position was found in 27 of 40 asymptomatic joints. At the intraobserver reliability of measurement, ICC at the closed and open mouth position were 0.89 and 0.91. The measurement error was 0.4% and 0.5%. At the interobserver reliability, ICC at the closed and open mouth position, the distances between the lateral surface of mandibular condyle and the articular capsule measured on MR images and ultrasonography were 2.0{+-} 0.7 mm, 1.8{+-}0.5 mm, respectively (p<0.05). On the ultrasonography, the distances at open mouth position were 1.2{+-}0.5 mm (p<0.05). At the TMJ with medially displaced disc, the distances at the closed and open mouth position were 1.3{+-}0.3 mm and 0.9{+-}0.2 mm (p<0.05). The results suggest ultrasonography of TMJ is a reliable imaging technique for assessment of normal disc position.

  15. Reliability of Ultrasonography in Confirming Endotracheal Tube Placement in an Emergency Setting

    Science.gov (United States)

    Thomas, Vimal Koshy; Paul, Cherish; Rajeev, Punchalil Chathappan; Palatty, Babu Urumese

    2017-01-01

    Background and Objectives: Over the past few years, ultrasonography is increasingly being used to confirm the correct placement of endotracheal tube (ETT). In our study, we aimed to compare it with the traditional clinical methods and the gold standard quantitative waveform capnography. Two primary outcomes were measured in our study. First was the sensitivity and specificity of ultrasonography against the other two methods to confirm endotracheal intubation. The second primary outcome assessed was the time taken for each method to confirm tube placement in an emergency setting. Methods: This is a single-centered, prospective cohort study conducted in an emergency department of a tertiary care hospital. We included 100 patients with indication of emergency intubation by convenient sampling. The intubation was performed as per standard hospital protocol. As part of the study protocol, ultrasonography was used to identify ETT placement simultaneously with the intubation procedure along with quantitative waveform capnography (end-tidal carbon dioxide) and clinical methods. Confirmation of tube placement and time taken for the same were noted by three separate health-care staffs. Results and Discussion: Out of the 100 intubation attempts, five (5%) had esophageal intubations. The sensitivity and specificity of diagnosis using ultrasonography were 97.89% and 100%, respectively. This was statistically comparable with the other two modalities. The time taken to confirm tube placement with ultrasonography was 8.27 ± 1.54 s compared to waveform capnography and clinical methods which were 18.06 ± 2.58 and 20.72 ± 3.21 s, respectively. The time taken by ultrasonography was significantly less. Conclusions: Ultrasonography confirmed tube placement with comparable sensitivity and specificity to quantitative waveform capnography and clinical methods. But then, it yielded results considerably faster than the other two modalities. PMID:28584427

  16. Bedside Ultrasonography versus Brain Natriuretic Peptide in Detecting Cardiogenic Causes of Acute Dyspnea

    Directory of Open Access Journals (Sweden)

    Keihan Golshani

    2016-04-01

    Full Text Available Acute dyspnea is a common cause of hospitalization in emergency departments (ED.Distinguishing the cardiac causes of acute dyspnea from pulmonary ones is a major challenge for responsible physicians in EDs. This study compares the characteristics of bedside ultrasonography with serum level of blood natriuretic peptide (BNP in this regard. Methods: This diagnostic accuracy study compares bedside ultrasonography with serum BNP levels in differentiating cardiogenic causes of acute respiratory distress. Echocardiography was considered as the reference test. A checklist including demographic data (age and sex, vital signs, medical history, underlying diseases, serum level of BNP, as well as findings of chest radiography, chest ultrasonography, and echocardiography was filled for all patients with acute onset of dyspnea. Screening characteristics of the two studied methods were calculated and compared using SPSS software, version 20. Results: 48 patients with acute respiratory distress were evaluated (50% female. The mean age of participants was 66.94 ± 16.33 (28-94 years. Based on the results of echocardiography and final diagnosis, the cause of dyspnea was cardiogenic in 20 (41.6% cases. Bedside ultrasonography revealed the cardiogenic cause of acute dyspnea in 18 cases (0 false positive and BNP in 44 cases (24 false positives. The area under the ROC curve for bedside ultrasonography and BNP for differentiating the cardiogenic cause of dyspnea were 86.4 (95% CI: 74.6-98.3 and 66.3 (95% CI: 49.8-89.2, respectively (p = 0.0021. Conclusion: It seems that bedside ultrasonography could be considered as a helpful and accurate method in differentiating cardiogenic causes of acute dyspnea in emergency settings. Nevertheless, more study is needed to make a runaway algorithm to evaluate patients with respiratory distress using bedside ultrasonography, which leads to rapid therapeutic decisions in a short time.

  17. The Efficacy of Thoracic Ultrasonography in Postoperative Newborn Patients after Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Erkut Ozturk

    Full Text Available Abstract Objective: In this study, the efficacy of thoracic ultrasonography during echocardiography was evaluated in newborns. Methods: Sixty newborns who had undergone pediatric cardiac surgery were successively evaluated between March 1, 2015, and September 1, 2015. Patients were evaluated for effusion, pulmonary atelectasis, and pneumothorax by ultrasonography, and results were compared with X-ray findings. Results: Sixty percent (n=42 of the cases were male, the median age was 14 days (2-30 days, and the median body weight was 3.3 kg (2.8-4.5 kg. The median RACHS-1 score was 4 (2-6. Atelectasis was demonstrated in 66% (n=40 of the cases. Five of them were determined solely by X-ray, 10 of them only by ultrasonography, and 25 of them by both ultrasonography and X-ray. Pneumothorax was determined in 20% (n=12 of the cases. Excluding one case determined by both methods, all of the 11 cases were diagnosed by X-ray. Pleural effusion was diagnosed in 26% (n=16 of the cases. Four of the cases were demonstrated solely by ultrasonography, three of them solely by X-ray, and nine of the cases by both methods. Pericardial effusion was demonstrated in 10% (n=6 of the cases. Except for one of the cases determined by both methods, five of the cases were diagnosed by ultrasonography. There was a moderate correlation when all pathologies evaluated together (k=0.51. Conclusion: Thoracic ultrasonography might be a beneficial non-invasive method to evaluate postoperative respiratory problems in newborns who had congenital cardiac surgery.

  18. Detection of rib fractures in minor chest injuries: a comparison between ultrasonography and radiography performed on the same day

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Soo; Back, Chang Hee; Lee, Kyung Rae; Shin, Yun Hack; Whang, Yeong Seop; Jeong, Ku Young [Yeosu Baek Hospital, Yeosu (Korea, Republic of); Chung, Soo Hyun [NamWon Medical Center, NamWon (Korea, Republic of); Whang, Cheol Mog [Konyang University Hospital, Daejeon (Korea, Republic of)

    2007-04-15

    We wished to compare the ability of ultrasonography and radiography performed on the same day to detect rib fractures in minor chest injuries. Two hundred and fifteen patients with minor chest injuries were selected. Radiography and ultrasonography were performed on the same day with these patients. Chest wall pain was the only presenting symptom. Two radiologists performed ultrasonography. Fractures were identified by a disruption of the anterior margin of the rib and costal cartilage. The incidence and location of fractures and complications revealed by radiography and ultrasonography were compared. Radiographs revealed the presence of 70 rib fractures in 50 (23%) of 215 patients and ultrasonography revealed the presence of 203 rib fractures in 133 (62%) of 215 patients. Ultrasonography uniquely identified 133 rib fractures in 83 patients. Ultrasonography identified a 2.9 fold increase in the number of fractures in a 2.6 fold number of subjects as compared to radiography. Of the 203 sonographically detected fractures, 201 were located in the rib, one was located at the costochondral junction, and one in the costal cartilage. There were no complications seen by either radiography or ultrasonography. Ultrasonography reveals more fractures than those that may be overlooked on radiography for minor chest injuries.

  19. Detection of rib fractures in minor chest injuries: a comparison between ultrasonography and radiography performed on the same day

    International Nuclear Information System (INIS)

    Cho, Yong Soo; Back, Chang Hee; Lee, Kyung Rae; Shin, Yun Hack; Whang, Yeong Seop; Jeong, Ku Young; Chung, Soo Hyun; Whang, Cheol Mog

    2007-01-01

    We wished to compare the ability of ultrasonography and radiography performed on the same day to detect rib fractures in minor chest injuries. Two hundred and fifteen patients with minor chest injuries were selected. Radiography and ultrasonography were performed on the same day with these patients. Chest wall pain was the only presenting symptom. Two radiologists performed ultrasonography. Fractures were identified by a disruption of the anterior margin of the rib and costal cartilage. The incidence and location of fractures and complications revealed by radiography and ultrasonography were compared. Radiographs revealed the presence of 70 rib fractures in 50 (23%) of 215 patients and ultrasonography revealed the presence of 203 rib fractures in 133 (62%) of 215 patients. Ultrasonography uniquely identified 133 rib fractures in 83 patients. Ultrasonography identified a 2.9 fold increase in the number of fractures in a 2.6 fold number of subjects as compared to radiography. Of the 203 sonographically detected fractures, 201 were located in the rib, one was located at the costochondral junction, and one in the costal cartilage. There were no complications seen by either radiography or ultrasonography. Ultrasonography reveals more fractures than those that may be overlooked on radiography for minor chest injuries

  20. Use of gray-scale ultrasonography in the diagnosis of reproductive disease in the bitch: 18 cases (1981-1984)

    International Nuclear Information System (INIS)

    Poffenbarger, E.M.; Feeney, D.A.

    1986-01-01

    Gray-scale ultrasonography was utilized in addition to radiography in the diagnosis of reproductive disease in 18 bitches. In 72% of the cases, ultrasonography was considered diagnostic because it revealed information on organ architecture, relationships of radiographically silhouetting soft tissue structures, and fetal viability that was unobtainable by radiography alone. In the remainder of the cases, ultrasonography was contributory to the diagnostic process by supporting the clinical and radiographic diagnoses. The benefits of ultrasonography are discussed, as is the ultrasonographic appearance of a variety of reproductive tract diseases

  1. Ultrasonography for Proper Endotracheal Tube Placement Confirmation in Out-of-hospital Cardiac Arrest Patients: Two-center Experience

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Conclusion: Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during cardiopulmonary resuscitation without the need for interruption of chest compression.

  2. Short-term outcomes and nutritional status after laparoscopic subtotal gastrectomy with a very small remnant stomach for cStage I proximal gastric carcinoma.

    Science.gov (United States)

    Furukawa, Haruna; Kurokawa, Yukinori; Takiguchi, Shuji; Tanaka, Koji; Miyazaki, Yasuhiro; Makino, Tomoki; Takahashi, Tsuyoshi; Yamasaki, Makoto; Nakajima, Kiyokazu; Mori, Masaki; Doki, Yuichiro

    2018-05-01

    Total or proximal gastrectomy is usually performed for early proximal gastric carcinoma, but the optimal type of gastrectomy is still unknown. We evaluated short-term outcomes and nutritional status after laparoscopic subtotal gastrectomy (LsTG) in comparison with laparoscopic total gastrectomy (LTG) and laparoscopic proximal gastrectomy (LPG). We analyzed 113 patients who underwent LsTG (n = 38), LTG (n = 48), or LPG (n = 27) for cStage I gastric cancer located in the upper third of the stomach. Postoperative morbidities, nutritional status including body weight, serum albumin, hemoglobin, the prognostic nutritional index (PNI), and endoscopic findings at 1 year after surgery were compared between LsTG and both LTG and LPG. Operation time and intraoperative blood loss were similar among the three groups. The incidence of postoperative morbidities was lower in LsTG than in LTG. The degree of body weight loss was significantly smaller in LsTG than in LTG at 6 and 12 months. At 12 months, LsTG resulted in better serum albumin and PNI than LPG, and better hemoglobin than LTG. Endoscopic examination demonstrated that one LsTG patient and two LPG patients had reflux esophagitis. Remnant gastritis was observed more frequently in LPG than in LsTG. No LsTG patient had bile reflux, although it was observed in four LPG patients. LsTG with a very small remnant stomach had favorable short-term outcomes and nutritional status compared with LTG and LPG, so it may be a better treatment option for cStage I proximal gastric carcinoma.

  3. Rectosigmoid stump washout as an alternative to permanent mucous fistula in patients undergoing subtotal colectomy for ulcerative colitis in emergency settings.

    Science.gov (United States)

    Pellino, Gianluca; Sciaudone, Guido; Candilio, Giuseppe; Canonico, Silvestro; Selvaggi, Francesco

    2012-01-01

    Restorative proctocolectomy with ileopouch-anal anastomosis (IPAA) is the treatment of choice for intractable or complicated ulcerative colitis(UC). Elderly patients often present with acute colitis requiring emergent subtotal colectomy(SC). Frail patients are at risk of developing septic complications related to the closed rectosigmoidal stump, often requiring formation of a second stoma to be reversed at the time of completion proctectomy. This carries nuisance to such exhausted patients. We propose a simple and inexpensive trick to avoid the need for creating a mucous fistula. IPAA was performed as a 3-stage procedure in emergency settings. The rectosigmoidal stump was closed and placed subcutaneously; skin was closed over it. After SC, if patients showed signs of stump-related pelvic sepsis, a lavage of the rectal stump with povidone iodine solution and with saline was carried out as a rescue treatment aiming to avoid the need of opening the rectal stump to drain sepsis. Thirty-five patients underwent SC for UC between 1987 and 2012. The skin was closed over the closed stump in the 20. Seven patients out of these 20 experienced early stump-related septic complication. In five cases, we were able to avoid opening of the rectal stump, and a second stoma was unnecessary. After opening the closed stump in the remaining ones, a prompt improving of symptoms was observed. Rectal washout was well tolerated and avoided a second stoma in five out of seven patients, with better quality of life and body perception after IPAA surgery. This is relevant when dealing with geriatric patients, needing to completely recover before undergoing completion proctectomy.

  4. Evaluation of the activity of synovitis in patients with rheumatoid arthritis: Value of power Doppler ultrasonography

    International Nuclear Information System (INIS)

    Ahn, Joong Mo; Lim, Hyo Keun; Kim, Seung Hoon; Kim, Sung Hyun; Koh, Eun Mi; Kim, Jin Seok; Cha, Hoon Suk

    2001-01-01

    To correlate the grades on power Doppler ultrasonography with clinical disease activity indices and acute phase reactant values for assessing the activity of synovitis in patients with rheumatoid arthritis. Twenty patients with rheumatoid arthritis diagnosed on the basis of American College of power Doppler ultrasonography. Two experienced radiologists evaluated, in consensus, the power Doppler signals as follows: grade I=no flow or minimal flow, grade 2=mild flow, grade 3=moderate flow and grade 4= marked flow. The clinical disease activity indices consisted of the counts of tender joints and swollen joints, patient's assessment of pain, patient's global assessment of disease activity, physician's globe assessment of disease activity and patient's assessment of physical function. Acute-phase reactants included CRP and ESR. The grades on power Doppler ultrasonography were correlated with clinical disease activity indices as well as acute-phases reactant values by a use of Spearman rank correlation coefficient. The grades on power Doppler ultrasonography showed a statistically significant correlation with tender joint count (rs=.835; p<.05), swollen joint count (rs=.833; p<.05), physician's global assessment of disease activity (rs=.857; p<.05), CRP (rs=.838; P<.05) and ESR (rs=.838; p<.05). The power Doppler ultrasonography is an useful diagnostic modality for assessing the activity of synovitis in patients with rheumatoid arthritis.

  5. Contrast-enhanced ultrasonography depicts small tumor vessels for the evaluation of pancreatic tumors

    International Nuclear Information System (INIS)

    Okamoto, Yuko; Kawamoto, Hirofumi; Takaki, Akinobu; Ishida, Etsuji; Ogawa, Tsuneyoshi; Kuwaki, Kenji; Kobayashi, Yoshiyuki; Sakaguchi, Kohsaku; Shiratori, Yasushi

    2007-01-01

    Objective: The aim of this study is to evaluate the efficacy of contrast-enhanced ultrasonography for the diagnosis of pancreatic tumors. Materials and methods: Contrast-enhanced ultrasonography with Levovist was performed on 62 consecutive patients (53 with pancreatic cancer, 4 with islet cell tumor, 3 with inflammatory pancreatic tumor, and 2 with metastatic tumor). The vascular and perfusion image phases of the tumors were evaluated and compared with the findings of contrast-enhanced computed tomography. Results: Contrast-enhanced ultrasonography showed tumor vessels around and/or in the tumor at the vascular image phase in 79% of pancreatic cancer patients (42/53). At the perfusion image phase, 96% of pancreatic cancers (51/53) were classified as hypo-enhancement type. However, tiny spotty or irregular heterogeneous enhanced lesions were found in 84% of hypo-enhanced pancreatic cancer patients (43/51). The presence of small vessels at the vascular image phase was closely correlated with the presence of these intratumor regional enhanced lesions at the perfusion image phase (κ coefficient = 0.42). The sensitivity of contrast-enhanced ultrasonography (100%) for pancreatic cancer was superior to that of contrast-enhanced computed tomography (91%), but no significant difference was observed between the two (McNemar test: p = 0.063). Conclusion: Contrast-enhanced ultrasonography with Levovist successfully visualizes fine vessels and enhancement in pancreatic tumors, and is useful for evaluating pancreatic tumors

  6. Ultrasonography of symptomatic rotator cuff tears compared with MR imaging and surgery

    International Nuclear Information System (INIS)

    Fotiadou, Anastasia N.; Vlychou, Marianna; Papadopoulos, Periklis; Karataglis, Dimitrios S.; Palladas, Panagiotis; Fezoulidis, Ioannis V.

    2008-01-01

    Purpose: To compare the accuracy of ultrasonography and magnetic resonance imaging in the detection of rotator cuff tears. Materials and methods: Ninety-six patients with clinically suspected rotator cuff pathology underwent ultrasonography and magnetic resonance imaging of the shoulder. The findings in 88 patients were compared with arthroscopy or open surgery. Results: Full-thickness tear was confirmed in 57 cases, partial-thickness tear in 30 cases and degenerative changes without tear in 1. In all 57 cases of full-thickness tear and in 28 out of 30 cases of partial-thickness tear the supraspinatus tendon was involved. The accuracy in the detection of full-thickness tears was 98 and 100% for ultrasonography and magnetic resonance imaging, respectively. The accuracy in the detection of bursal or articular partial-thickness tears was 87 and 90% for ultrasonography and magnetic resonance imaging, respectively. Conclusions: In experienced hands ultrasonography should be considered as an accurate modality for the initial investigation of rotator cuff, especially supraspinatus, tears

  7. Accuracy of ultrasonography and magnetic resonance imaging in the diagnosis of placenta accreta.

    Science.gov (United States)

    Riteau, Anne-Sophie; Tassin, Mikael; Chambon, Guillemette; Le Vaillant, Claudine; de Laveaucoupet, Jocelyne; Quéré, Marie-Pierre; Joubert, Madeleine; Prevot, Sophie; Philippe, Henri-Jean; Benachi, Alexandra

    2014-01-01

    To evaluate the accuracy of ultrasonography and magnetic resonance imaging (MRI) in the diagnosis of placenta accreta and to define the most relevant specific ultrasound and MRI features that may predict placental invasion. This study was approved by the institutional review board of the French College of Obstetricians and Gynecologists. We retrospectively reviewed the medical records of all patients referred for suspected placenta accreta to two university hospitals from 01/2001 to 05/2012. Our study population included 42 pregnant women who had been investigated by both ultrasonography and MRI. Ultrasound images and MRI were blindly reassessed for each case by 2 raters in order to score features that predict abnormal placental invasion. Sensitivity in the diagnosis of placenta accreta was 100% with ultrasound and 76.9% for MRI (P = 0.03). Specificity was 37.5% with ultrasonography and 50% for MRI (P = 0.6). The features of greatest sensitivity on ultrasonography were intraplacental lacunae and loss of the normal retroplacental clear space. Increased vascularization in the uterine serosa-bladder wall interface and vascularization perpendicular to the uterine wall had the best positive predictive value (92%). At MRI, uterine bulging had the best positive predictive value (85%) and its combination with the presence of dark intraplacental bands on T2-weighted images improved the predictive value to 90%. Ultrasound imaging is the mainstay of screening for placenta accreta. MRI appears to be complementary to ultrasonography, especially when there are few ultrasound signs.

  8. Ultrasonography of symptomatic rotator cuff tears compared with MR imaging and surgery

    Energy Technology Data Exchange (ETDEWEB)

    Fotiadou, Anastasia N. [Radiology Department, University Hospital of Larissa, Mezourlo 41110, Larissa (Greece); Radiology Department, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: natfot@yahoo.gr; Vlychou, Marianna [Radiology Department, University Hospital of Larissa, Mezourlo 41110, Larissa (Greece)], E-mail: mvlychou@med.uth.gr; Papadopoulos, Periklis [University Orthopaedic Clinic, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: perpap@otenet.gr; Karataglis, Dimitrios S. [University Orthopaedic Clinic, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: dkarataglis@yahoo.gr; Palladas, Panagiotis [Radiology Department, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: palladaspan@in.gr; Fezoulidis, Ioannis V. [Radiology Department, University Hospital of Larissa, Mezourlo 41110, Larissa (Greece)], E-mail: oswestanast@yahoo.gr

    2008-10-15

    Purpose: To compare the accuracy of ultrasonography and magnetic resonance imaging in the detection of rotator cuff tears. Materials and methods: Ninety-six patients with clinically suspected rotator cuff pathology underwent ultrasonography and magnetic resonance imaging of the shoulder. The findings in 88 patients were compared with arthroscopy or open surgery. Results: Full-thickness tear was confirmed in 57 cases, partial-thickness tear in 30 cases and degenerative changes without tear in 1. In all 57 cases of full-thickness tear and in 28 out of 30 cases of partial-thickness tear the supraspinatus tendon was involved. The accuracy in the detection of full-thickness tears was 98 and 100% for ultrasonography and magnetic resonance imaging, respectively. The accuracy in the detection of bursal or articular partial-thickness tears was 87 and 90% for ultrasonography and magnetic resonance imaging, respectively. Conclusions: In experienced hands ultrasonography should be considered as an accurate modality for the initial investigation of rotator cuff, especially supraspinatus, tears.

  9. An experimental comparative study of radiography, ultrasonography and CT imaging in the IV catheter fragment

    International Nuclear Information System (INIS)

    Kweon, Dae Cheol

    2016-01-01

    The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon® IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose (0.2139 mSv·Gy-1·cm-2) form DAP DAP (0.93 μGy·m2 ), and dose length product (DLP) (201 mGy·cm) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography

  10. The diagnostic concordance of endoanal ultrasonography and endoanal MRI in cases of anorectal fistula

    International Nuclear Information System (INIS)

    Kim, Wan Tae; Yoo, Weon Young; Moon, Hee Jung; Shin, Hyun Ja; Joo, Jae Sik

    2000-01-01

    To evaluate the preoperative diagnostic concordance of morphologic classification of anorectal fistula by endoanal ultrasonography (EUSG) and endoanal magnetic resonance imaging (EMRI). Between January 1998 and March 1999, 17 patients with anorectal fistula underwent endoanal ultrasonography and magnetic resonance imaging for preoperative assessment. The types of fistula and abscess formation were evaluated, and the findings compared with those obtained during surgery. The overall accordance of anorectal fistula was 76% (13 of 17 cases) on ultrasonography and 94% (16 of 17 cases) on magnetic resonance imaging. According to the findings of EUSG, the accordance of each type of anorectal fistula was as follows: transphineteric, 92% (11 of 12 cases); suprasphinteric, 33% (1 of 3); and extrasphincteric, 50% (1 of 2), while for EMRI, the respective figures were 100% (12 of 12 cases), 67% (2 of 3), and 100% (2 of 2). An analysis of reproducibility using kappa value showed that overall concordance between endoanal ultrasonography and surgery (κ=0.820) as well as between endoanal MRI and surgery (κ=0.866), was very close. For the evaluation of anorectal fistula, preoperative endoanal magnetic resonance imaging was more accurate and informative than endoanal ultrasonography

  11. The current status and future prospects of breast cancer screening using ultrasonography at our facility

    International Nuclear Information System (INIS)

    Morikubo, Hiroshi; Ichimura, Miyuki; Abe, Satoko

    2011-01-01

    We report the results obtained by breast cancer screening of the general population using both ultrasonography and mammography conducted by the Tochigi Public Health Service Association. An investigation of breast cancer screening carried out on approximately 140,000 participants between 2000 and 2007 showed that ultrasonography and mammography are remarkably complementary for detection of breast cancer, particularly for women in their 40s and 50s, and that each modality improves the sensitivity of breast cancer detection by approximately 20%. The following issues are pivotal for establishing a breast cancer ultrasonography screening system that is able to maintain high precision and adequate efficiency: technical training of sonographers and physicians who must interpret the sonographic images, quality control of equipment, and an interpretation system that allows previous sonographs to be used as a reference. In independent combined screening systems using ultrasonography and mammography, the high recall rate becomes an issue. Comparative interpretation of sonographic images with previous sonographs is effective for resolving this. However, hopes abound for a comprehensive assessment system that allows simultaneous imaging and interpretation of both ultrasonography and mammography. (author)

  12. Comparison of ultrasonography and radiography in diagnosis of rib fractures.

    Science.gov (United States)

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-08-01

    Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. In this cross-sectional study, consecutive patients with minor blunt chest trauma and suspected rib fractures presenting in Imam Reza Hospital located in Mashhad-Iran, between April 2013 and October 2013 were assessed by USG and radiography. The radiography was performed in a posteroanterior (PA) chest projection and oblique rib view centered over the area of trauma. The time duration spent in taking USG and radiography were recorded. The prevalence and location of fractures revealed by USG and radiography were compared. Sixty-one suspected patients were assessed. The male to female ratio was 2.4:1 (43 men and 18 women) with a mean ± SD age of (44.3 ± 19.7) years. There were totally 59 rib fractures in 38 (62.3%) patients based on radiography and USG, while 23 (37.7%) patients had no diagnostic evidence of rib lesions. USG revealed 58 rib fractures in 33 (54.1%) of 61 suspected patients and radiographs revealed 32 rib fractures in 20 (32.8%) of 61 patients. A total of 58 (98.3%) rib fractures were detected by USG, whereas oblique rib view and PA chest radiography showed 27 (45.8%) and 24 (40.7%) rib fractures, respectively. The average duration of USG was (12 ± 3) min (range 7-17 min), whereas the duration of radiography was (27 ± 6) min (range 15-37 min). The kappa coefficient showed a low level of agreement between both USG and PA chest radiography (kappa coefficient = 0.28), and between USG and oblique rib view (kappa coefficient = 0.32). USG discloses more fractures than radiography in

  13. Predictors of diagnostic success with renal artery duplex ultrasonography.

    Science.gov (United States)

    Hedayati, Nasim; Del Pizzo, David J; Harris, Sean E; Kuskowski, Michael; Pevec, William C; Lee, Eugene S; Pifer, Christy; Dawson, David L

    2011-05-01

    Renal artery duplex ultrasonography (RA-DUS) is commonly used for the evaluation and follow-up of renal artery atherosclerotic disease. In a complete study, renal artery flow is evaluated from the vessel origin to the intraparenchymal branches. The quality of RA-DUS is in part technologist-dependent, but many factors may affect the ability to complete a diagnostic examination. This study evaluated the clinical and technical factors that predict the ability to obtain a complete RA-DUS examination. A prospective evaluation of all patients undergoing RA-DUS between July 2008 and February 2009 was performed. Factors such as patient age, gender, body mass index, technologists' years of experience, patient care setting (inpatient vs. outpatient), bedside examination, smoking before the examination, fasting status, and recent abdominal surgery were all recorded. Multivariate logistic regression analysis was performed. A p value of ≤ 0.05 was considered significant. During the study period, 250 patients underwent RA-DUS (mean age: 59.9 ± 17.8 years, 57% [143] female). A total of 87 (35%) examinations were incomplete. This included nondiagnostic examinations which did not exhibit any segment of the renal artery. Factors that were associated with an incomplete examination included technologists' years of experience (OR = 0.92, p = 0.042), bedside examination (OR = 4.17, p = 0.016), and recent abdominal surgery (OR = 3.45, p = 0.047). Body mass index, fasting status, and smoking before the examination did not affect the ability to obtain a complete study. One-third of the RA-DUS studies were classified as incomplete by the strict criteria used in this prospective study. An experienced ultrasound technologist is more likely to obtain a complete RA-DUS examination. Recent abdominal surgery and bedside examinations were predictive of a limited examination as well. Vascular laboratories should consider these factors when scheduling examinations so as to obtain complete RA

  14. Measurement of Gallbladder Volume with Ultrasonography in Pregnant Women

    Directory of Open Access Journals (Sweden)

    Sait Kapicioglu

    2000-01-01

    Full Text Available Fasting and postprandial gallbladder volumes were investigated using ultrasonography in three groups (10 subjects in each of healthy women: third trimester pregnant women, postpartum women up to 10 days after giving birth and nonpregnant controls. The scans were performed at 09:00 after a 12 h fast. After the basal measurement was taken, gallbladder volumes were rescanned in 15 min intervals for 60 mins. At the end of this period, all volunteers received a standard liquid test meal, and scans were performed again for 1 h. The mean basal gallbladder volume was 22.2±4.2 mL in the nonpregnant (control group. In the third trimester group, the basal volume was 37.8±10.5 mL – 70.5% higher than in the nonpregnant group (P<0.001. In the postpartum group, the mean basal volume was 37.9% lower (27.4±6.5 mL than that of the third trimester group (P<0.02. This basal volume was 23.6% greater than that of the control group (P<0.05. After administration of a test meal, the postprandial gallbladder volumes decreased during the first few minutes compared with baseline values. The volumes decreased by 10.2% to 39.8% (23.5±7.3 to 34.0±10.2; P<0.01 in the third trimester group, by 14.9% to 43.2% (16.6±4.3 to 23.3±5.5; P<0.01, 0.001 in the postpartum group and by 19.2% to 51.6% (11.9±3.5 to 17.9±3.6; P<0.02, 0.05, 0.01, 0.001 in the control group. Postprandial mean gallbladder volumes of the third trimester (P<0.02 and postpartum groups (P<0.02 to 0.01 were significantly different from those of the control group. In conclusion, incomplete emptying of the gallbladder after eating during the third trimester of pregnancy may contribute to cholesterol-gallstone formation, and pregnancy may thus increase the risk of gallstones.

  15. Diagnosis and treatment of postoperative intraperitoneal abscess using ultrasonography and abdominal computed tomography

    International Nuclear Information System (INIS)

    Kamachi, Hisashi; Kumashiro, Ryunosuke; Maekawa, Takafumi; Saku, Haruhisa; Naitoh, Hideaki; Inutsuka, Sadamitsu; Higashi, Yoshitaka

    1988-01-01

    Ultrasonography and/or abdominal computed tomography revealed 9 patients with subphrenic abscesses derived from gastrointestinal surgery. Out of them 4 cases underwent conservative treatment is chosen with aggresive chemotherapy, but 5 were re-surgically treated including drainage of the intraperitonial abscess or repairing the leakage of the anastomosis. On the conservative treatment for the intraperitonial abscess, frequent monitoring with ultrasonography was very conventional for successful treatment. However, in the cases with severe leukocytosis, leakage of anastomosis or recurrent intraperitonial abscess, resurgical treatment will be required. Thus the monitoring with ultrasonography is quite usefull not only in the drainaging of the intraperitonial abscess, but also in the judgement of treatment whether conservetive or re-operative. (author)

  16. Diagnostic Ultrasonography of an Ankle Fracture Undetectable by Conventional Radiography: A Case Report

    Science.gov (United States)

    Daniels, Clinton J.; Welk, Aaron B.; Enix, Dennis E.

    2016-01-01

    Objective The purpose of this study is to present diagnostic ultrasonography assessment of an occult fracture in a case of persistent lateral ankle pain. Clinical Features A 35-year-old woman presented to a chiropractic clinic with bruising, swelling, and pain along the distal fibula 3 days following an inversion ankle trauma. Prior radiographic examination at an urgent care facility was negative for fracture. Conservative care over the next week noted improvement in objective findings, but the pain persisted. Intervention and Outcome Diagnostic ultrasonography was ordered to assess her persistent ankle pain and showed a minimally displaced fracture of the fibula 4 cm proximal to the lateral malleolus. The patient was referred to her primary care physician and successfully managed with conservative care. Conclusion In this case, diagnostic ultrasonography was able to identify a Danis-Weber subtype B1 fracture that was missed by plain film radiography. PMID:27069430

  17. Atrophy of foot muscles in diabetic patients can be detected with ultrasonography

    DEFF Research Database (Denmark)

    Severinsen, Kaare; Obel, Annette; Jakobsen, Johannes

    2007-01-01

    OBJECTIVE: To establish a bedside test with ultrasonography for evaluation of foot muscle atrophy in diabetic patients. RESEARCH DESIGN AND METHODS: Thickness and cross-sectional area (CSA) of the extensor digitorum brevis muscle (EDB) and of the muscles of the first interstitium (MILs) were...... determined in 26 diabetic patients and in 26 matched control subjects using ultrasonography. To estimate the validity, findings were related to the total volume of all foot muscles determined at magnetic resonance imaging (MRI-FM(vol)). Furthermore, the relations of ultrasonographic estimates to nerve...... than in nonneuropathic diabetic patients (5.8 +/- 2.1 vs. 7.5 +/- 1.7 mm [P foot muscles determined at ultrasonography is directly related to foot muscle volume determined by MRI and to various...

  18. Pancreatic duct drainage using EUS-guided rendezvous technique for stenotic pancreaticojejunostomy.

    Science.gov (United States)

    Takikawa, Tetsuya; Kanno, Atsushi; Masamune, Atsushi; Hamada, Shin; Nakano, Eriko; Miura, Shin; Ariga, Hiroyuki; Unno, Jun; Kume, Kiyoshi; Kikuta, Kazuhiro; Hirota, Morihisa; Yoshida, Hiroshi; Katayose, Yu; Unno, Michiaki; Shimosegawa, Tooru

    2013-08-21

    The patient was a 30-year-old female who had undergone excision of the extrahepatic bile duct and Roux-en-Y hepaticojejunostomy for congenital biliary dilatation at the age of 7. Thereafter, she suffered from recurrent acute pancreatitis due to pancreaticobiliary maljunction and received subtotal stomach-preserving pancreaticoduodenectomy. She developed a pancreatic fistula and an intra-abdominal abscess after the operation. These complications were improved by percutaneous abscess drainage and antibiotic therapy. However, upper abdominal discomfort and the elevation of serum pancreatic enzymes persisted due to stenosis from the pancreaticojejunostomy. Because we could not accomplish dilation of the stenosis by endoscopic retrograde cholangiopancreatography, we tried an endoscopic ultrasonography (EUS) guided rendezvous technique for pancreatic duct drainage. After transgastric puncture of the pancreatic duct using an EUS-fine needle aspiration needle, the guidewire was inserted into the pancreatic duct and finally reached to the jejunum through the stenotic anastomosis. We changed the echoendoscope to an oblique-viewing endoscope, then grasped the guidewire and withdrew it through the scope. The stenosis of the pancreaticojejunostomy was dilated up to 4 mm, and a pancreatic stent was put in place. Though the pancreatic stent was removed after three months, the patient remained symptom-free. Pancreatic duct drainage using an EUS-guided rendezvous technique was useful for the treatment of a stenotic pancreaticojejunostomy after pancreaticoduodenectomy.

  19. A case of pancreatic neuroendocrine tumor in a patient with neurofibromatosis-1

    Directory of Open Access Journals (Sweden)

    Nishi Takeshi

    2012-07-01

    Full Text Available Abstract Patients with neurofibromatosis-1 (NF-1 sometime develop neuroendocrine tumors (NET. Although these NETs usually occur in the duodenum or peri-ampullary region, they occasionally grow in the pancreas (PNET. A 62-year-old man with NF-1 had mild liver dysfunction and was admitted to our hospital for further examination. An abdominal contrast-enhanced computed tomography scan demonstrated a 30-mm tumor in the head of the pancreas. The scan showed an invasion of the tumor into the duodenum, and biopsy under an endoscopic ultrasonography indicated that the tumor was a NET. A subtotal stomach-preserving pancreaticoduodenectomy was performed. Macroscopically, the pancreatic tumor was white and elastic hard. Microscopically, tumor cells were composed of ribbons, cords, and solid nests with an acinus-like structure. The tumor was diagnosed as NET G2 according to the WHO classification (2010. The product of theNF-1 gene, i.e., neurofibromin, was weakly positive in the tumor cells, suggesting that the tumor was induced by a mutation in the NF-1 gene. This is the seventh case of PNET arising in NF-1 patients worldwide.

  20. Ability of Ultrasonography in Detection of Different Extremity Bone Fractures; a Case Series Study.

    Science.gov (United States)

    Bozorgi, Farzad; Shayesteh Azar, Massoud; Montazer, Seyed Hossein; Chabra, Aroona; Heidari, Seyed Farshad; Khalilian, Alireza

    2017-01-01

    Despite radiography being the gold standard in evaluation of orthopedic injuries, using bedside ultrasonography has several potential supremacies such as avoiding exposure to ionizing radiation, availability in pre-hospital settings, being extensively accessible, and ability to be used on the bedside. The aim of the present study is to evaluate the diagnostic accuracy of ultrasonography in detection of extremity bone fractures. This study is a case series study, which was prospectively conducted on multiple blunt trauma patients, who were 18 years old or older, had stable hemodynamic, Glasgow coma scale 15, and signs or symptoms of a possible extremity bone fracture. After initial assessment, ultrasonography of suspected bones was performed by a trained emergency medicine resident and prevalence of true positive and false negative findings were calculated compared to plain radiology. 108 patients with the mean age of 44.6 ± 20.4 years were studied (67.6% male). Analysis was done on 158 sites of fracture, which were confirmed with plain radiography. 91 (57.6%) cases were suspected to have upper extremity fracture(s) and 67 (42.4%) to have lower ones. The most frequent site of injuries were forearm (36.7%) in upper limbs and leg (27.8%) in lower limbs. Prevalence of true positive and false negative cases for fractures detected by ultrasonography were 59 (64.8%) and 32 (35.52%) for upper and 49 (73.1%) and 18 (26.9%) for lower extremities, respectively. In addition, prevalence of true positive and false negative detected cases for intra-articular fractures were 24 (48%) and 26 (52%), respectively. The present study shows the moderate sensitivity (68.3%) of ultrasonography in detection of different extremity bone fractures. Ultrasonography showed the best sensitivity in detection of femur (100%) and humerus (76.2%) fractures, respectively. It had low sensitivity in detection of in intra-articular fractures.

  1. Ultrasonographic detection of hepatocellular carcinoma: correlation of preoperative ultrasonography and resected liver pathology

    International Nuclear Information System (INIS)

    Lim, J.H.; Kim, S.H.; Lee, W.J.; Choi, D.; Kim, S.H.; Lim, H.K.

    2006-01-01

    AIM: The aim of this study was to determine the sensitivity of ultrasonography for detecting hepatocellular carcinoma in patients who underwent surgical liver resection. MATERIALS AND METHODS: The preoperative ultrasonography reports of 103 patients who underwent hepatic resection surgery were retrospectively reviewed. The patients had chronic liver disease with good liver function and a relatively normal liver echotexture. The presence of a mass or masses in the resected part of the liver segments on preoperative ultrasonography was regarded as possible hepatocellular carcinoma, and these results were compared with the surgically resected hepatic lobes or segments. Accuracy for detection was assessed on a lesion-by-lesion basis, on a segment-by-segment basis, and on a patient basis. RESULTS: One hundred and fifty-seven hepatocellular carcinomas were found in 244 hepatic segments of 103 patients. One hundred and one of 157 hepatocellular carcinomas were detected using ultrasonography in 97 patients resulting in a sensitivity of 64%. In six patients, a solitary hepatocellular carcinoma was missed in each patient, a patient sensitivity being 94%. Using ultrasonography, 87 of 100 (87%) hepatocellular carcinomas larger than 2 cm in diameter, and 14 of 57 (25%) hepatocellular carcinomas 2 cm or smaller in diameter were revealed. On the basis of segment-by-segment analysis, the sensitivity was 78% (99 of 127 segments), specificity was 97% (114 of 117 segments), accuracy was 87% (213 of 244 segments), positive predictive value was 97% (99 of 102 segments), and negative predictive value was 80% (114 of 142 segments). CONCLUSION: In patients with chronic liver disease and good hepatic function, ultrasonography has a sensitivity of 94% in the identification of affected patients, but for individual lesions, the sensitivity is only 64%

  2. Economic analysis of bedside ultrasonography (US) implementation in an Internal Medicine department.

    Science.gov (United States)

    Testa, Americo; Francesconi, Andrea; Giannuzzi, Rosangela; Berardi, Silvia; Sbraccia, Paolo

    2015-12-01

    The economic crisis, the growing healthcare demand, and Defensive Medicine wastefulness, strongly recommend the restructuring of the entire medical network. New health technology, such as bedside ultrasonography, might successfully integrate the clinical approach optimizing the use of limited resources, especially in a person-oriented vision of medicine. Bedside ultrasonography is a safe and reliable technique, with worldwide expanding employment in various clinical settings, being considered as "the stethoscope of the 21st century". However, at present, bedside ultrasonography lacks economic analysis. We performed a Cost-Benefit Analysis "ex ante", with a break-even point computing, of bedside ultrasonography implementation in an Internal Medicine department in the mid-term. Number and kind estimation of bedside ultrasonographic studies were obtained by a retrospective study, whose data results were applied to the next 3-year period (foresight study). All 1980 foreseen bedside examinations, with prevailing multiorgan ultrasonographic studies, were considered to calculate direct and indirect costs, while specific and generic revenues were considered only after the first semester. Physician professional training, equipment purchase and working time represented the main fixed and variable cost items. DRG increase/appropriateness, hospitalization stay shortening and reduction of traditional ultrasonography examination requests mainly impacted on calculated revenues. The break-even point, i.e. the volume of activity at which revenues exactly equal total incurred costs, was calculated to be 734 US examinations, corresponding to € 81,998 and the time considered necessary to reach it resulting 406 days. Our economic analysis clearly shows that bedside ultrasonography implementation in clinical daily management of an Internal Medicine department can produce consistent savings, or economic profit according to managerial choices (i.e., considering public or private targets

  3. Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation.

    Science.gov (United States)

    Chou, Hao-Chang; Chong, Kah-Meng; Sim, Shyh-Shyong; Ma, Matthew Huei-Ming; Liu, Shih-Hung; Chen, Nai-Chuan; Wu, Meng-Che; Fu, Chia-Ming; Wang, Chih-Hung; Lee, Chien-Chang; Lien, Wan-Ching; Chen, Shyr-Chyr

    2013-12-01

    This study aimed to evaluate the accuracy of tracheal ultrasonography for assessing endotracheal tube position during cardiopulmonary resuscitation (CPR). We performed a prospective observational study of patients undergoing emergency intubation during CPR. Real-time tracheal ultrasonography was performed during the intubation with the transducer placed transversely just above the suprasternal notch, to assess for endotracheal tube positioning and exclude esophageal intubation. The position of trachea was identified by a hyperechoic air-mucosa (A-M) interface with posterior reverberation artifact (comet-tail artifact). The endotracheal tube position was defined as endotracheal if single A-M interface with comet-tail artifact was observed. Endotracheal tube position was defined as intraesophageal if a second A-M interface appeared, suggesting a false second airway (double tract sign). The gold standard of correct endotracheal intubation was the combination of clinical auscultation and quantitative waveform capnography. The main outcome was the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR. Among the 89 patients enrolled, 7 (7.8%) had esophageal intubations. The sensitivity, specificity, positive predictive value, and negative predictive value of tracheal ultrasonography were 100% (95% confidence interval [CI]: 94.4-100%), 85.7% (95% CI: 42.0-99.2%), 98.8% (95% CI: 92.5-99.0%) and 100% (95% CI: 54.7-100%), respectively. Positive and negative likelihood ratios were 7.0 (95% CI: 1.1-43.0) and 0.0, respectively. Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during CPR without the need for interruption of chest compression. Tracheal ultrasonography in resuscitation management may serve as a powerful adjunct in trained hands. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  4. The pitfalls of ultrasonography in the evaluation of soft tissue masses

    International Nuclear Information System (INIS)

    Kwok, Henry CK.; Pinto, Clinton H.; Doyle, Anthony J.

    2012-01-01

    Ultrasonography is associated with a high error rate in the evaluation of soft tissue masses. The purposes of this study were to examine the nature of the diagnostic errors and to identify areas in which reporting could be improved. Patients who had soft tissue tumours and received ultrasonography during a 10-year period (1999–2009) were identified from a local tumour registry. The sonographic and pathological diagnoses were categorised as either ‘benign’ or ‘non-benign’. The accuracy of ultrasonography was assessed by correlating the sonographic with the pathological diagnostic categories. Recommendations from radiologists, where offered, were assessed for their appropriateness in the context of the pathological diagnosis. One hundred seventy-five patients received ultrasonography, of which 60 had ‘non-benign’ lesions and 115 had ‘benign’ lesions. Ultrasonography correctly diagnosed 35 and incorrectly diagnosed seven of the 60 ‘non-benign’ cases, and did not suggest a diagnosis in 18 cases. Most of the diagnostic errors related to misdiagnosing soft tissue tumours as haematomas (four out of seven). Recommendations for further management were offered by the radiologists in 144 cases, of which 52 had ‘non-benign’ pathology. There were eight ‘non-benign’ cases where no recommendation was offered, and the sonographic diagnosis was either incorrect or unavailable. Ultrasonography lacks accuracy in the evaluation of soft tissue masses. Ongoing education is required to improve awareness of the limitations with its use. These limitations should be highlighted to the referrers, especially those who do not have specific training in this area.

  5. Evaluation of Ultrasonography as a Diagnostic Tool in Maxillofacial Space Infections

    Directory of Open Access Journals (Sweden)

    Praveen Kumar Pandey

    2011-11-01

    Full Text Available Objectives: The purpose of the study was to establish the role of ultrasonography in determining the involvement of specific fascial spaces in maxillofacial region and the stage of infection, in indicating the appropriate time for surgical intervention and to compare clinical and ultrasonographic findings.Material and Methods: Twenty five patients with fascial space infection in maxillofacial region were subjected to ultrasonographic examination following a detailed clinical and radiological examination. Ultrasonography guided needle aspiration was performed. Based on the findings, patients diagnosed with abscess were subjected to incision and drainage and those with cellulitis were subjected to medical line of treatment.Results: More than one fascial space was involved in all patients. On clinical examination 64 spaces were involved, of them 34 spaces had abscess formation and 30 spaces were in the stage of cellulitis. On ultrasonography examination, 28 spaces were reported to have abscess formation and 36 spaces were diagnosed to be in the stage of cellulitis. On comparative analysis of both clinical and ultrasonographic findings, ultrasonography was found to be sensitive in 65% of the cases and having specificity of 80%. It was registered statistically significant (P < 0.001 agreement between these two methods of assessment (kappa index = 0.814.Conclusions: Ultrasonography is a quick, widely available, relatively inexpensive, and painless procedure and can be repeated as often as necessary without risk to the patient. Thus ultrasonography is a valuable diagnostic aid to the oral and maxillofacial surgeon for early and accurate diagnosis of fascial space infection, their appropriate treatment and to limit their further spread.

  6. Randomized clinical trial of laparoscopic ultrasonography before laparoscopic colorectal cancer resection

    DEFF Research Database (Denmark)

    Ellebaek, S B; Fristrup, C W; Hovendal, C

    2017-01-01

    BACKGROUND: Intraoperative ultrasonography during open surgery for colorectal cancer may be useful for the detection of unrecognized liver metastases. Laparoscopic ultrasonography (LUS) for the detection of unrecognized liver metastasis has not been studied in a randomized trial. This RCT tested...... in the LUS than in the control group (7·8 (95 per cent c.i. 3·8 to 13·8) and 0·8 (0 to 4·2) per cent respectively; P = 0·010), but the suspected M1 disease was benign in half of the patients. CONCLUSION: Routine LUS during resection of colorectal cancer is not recommended. Registration number: NCT02079389...

  7. A Case of Fetal Herpes Simplex Encephalitis Diagnosed Prenatally by Ultrasonography in the Third Trimester

    International Nuclear Information System (INIS)

    Lee, Mi Bum; Kim, Yu Ri; Hwang, Han Sung; Park, Yong Won; Kim, Young Han

    2007-01-01

    Almost all reported incidences of herpes simplex virus (HSV) infection in newborns result as a complication of rupture of the amniotic membranes or the delivery of the baby, but infection via the placenta and amniotic membranes is rare. Ventriculomegaly was detected at 36 weeks of gestation by prenatal ultrasonography, and an emergency cesarean section was then performed at 36 weeks of gestation. We report a case of herpes simplex encephalitis detected at 36 weeks of gestation by prenatal ultrasonography, which was confirmed by a postnatal serologic test and CSF test with a brief review of literature

  8. Reproducibility of ultrasonography for assessing abdominal fat distribution in a population at high risk of diabetes

    DEFF Research Database (Denmark)

    Philipsen, A; Carstensen, Bendix; Sandbæk, Annelli

    2013-01-01

    the reproducibility of this method have been published.Objective:The aim of this study was to investigate the reproducibility of ultrasonography in the assessment of abdominal fat distribution in a population at high risk of type 2 diabetes.Design and Methods:Ultrasonography was used to estimate visceral......- and interobserver variation, and Bland-Altman plots were drawn for all three substudies.Results:Coefficients of variation for intra- and interobserver variation were in the range 3.4-6.1%, except for interobserver variation for subcutaneous fat (9.5%). Short-term variation over a median of 35 days had a coefficient...

  9. Color Doppler Ultrasonography-Targeted Perforator Mapping and Angiosome-Based Flap Reconstruction

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Tei, Troels; Thomsen, Jørn Bo

    2016-01-01

    Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap reconstr......Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap...

  10. Comparison of radiography and ultrasonography in the evaluation of renal lesions in the dog

    International Nuclear Information System (INIS)

    Konde, L.J.; Park, R.D.; Wrigley, R.H.; Lebel, J.L.

    1986-01-01

    Survey abdominal radiographs, excretory urograms, and nephrosonograms were obtained from 14 dogs with renal lesions. Renal enlargement was suspected on survey radiographs and confirmed by excretory urography in 13 dogs. Radiographic differentiation between a solid and cystic renal lesion was not possible in 9 dogs. Ultrasonography determined the presence of solid masses in 12 dogs, established the presence of a renal cyst in the opposite kidney in 1 dog, and revealed hydronephrosis in 2 dogs. Ultrasonography appeared to be more sensitive than radiography in differentiating the internal characteristics of renal lesions

  11. A Case of Fetal Herpes Simplex Encephalitis Diagnosed Prenatally by Ultrasonography in the Third Trimester

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mi Bum; Kim, Yu Ri; Hwang, Han Sung; Park, Yong Won; Kim, Young Han [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2007-12-15

    Almost all reported incidences of herpes simplex virus (HSV) infection in newborns result as a complication of rupture of the amniotic membranes or the delivery of the baby, but infection via the placenta and amniotic membranes is rare. Ventriculomegaly was detected at 36 weeks of gestation by prenatal ultrasonography, and an emergency cesarean section was then performed at 36 weeks of gestation. We report a case of herpes simplex encephalitis detected at 36 weeks of gestation by prenatal ultrasonography, which was confirmed by a postnatal serologic test and CSF test with a brief review of literature

  12. HIGH-RESOLUTION ULTRASONOGRAPHY OF SHOULDER FOR ROTATOR CUFF TEAR: CORRELATION WITH ARTHROSCOPIC FINDINGS

    Directory of Open Access Journals (Sweden)

    Vishnumurthy H. Y

    2016-09-01

    Full Text Available INTRODUCTION Rotator cuff disease is the most common cause of shoulder pain. Ultrasonography being non-invasive, widely available, more cost-effective method and is the first choice in imaging of rotator cuff tears. Arthroscopy of shoulder is considered as the gold standard for diagnosis of rotator cuff tears. Objective of this study was to compare the diagnostic accuracy of high-resolution ultrasonography of shoulder for rotator cuff tears with arthroscopy of shoulder. METHODS Thirty patients clinically suspected to have rotator cuff tear who underwent ultrasonography and arthroscopy of shoulder were included in the study. Duration of study was for two years. All ultrasonography examinations were conducted in ultrasound machine using GE Voluson 730 PRO high frequency (10-12 MHz linear array transducer done by two experienced radiologists. Arthroscopies were done by two experienced shoulder arthroscopic surgeons. RESULTS Age of the patients with rotator cuff tears ranged from 40 to 80 years. 57% were females and 43% were males among the patients who had rotator cuff tears. 71.43% of the rotator cuff tears were found in the dominant arm. 64.28% of patients with rotator cuff tear had given history of fall or trauma to the corresponding shoulder within 6 months prior to presentation. 39.28% of patients who had rotator cuff tears were known diabetics. Supraspinatus tendon was the most commonly affected tendon, followed by infraspinatus and subscapularis tendons. For overall detection of rotator cuff tears, ultrasonography in comparison with the arthroscopy has sensitivity and specificity of 92.85% and 100%. For detection of full thickness rotator cuff tear, its sensitivity and specificity was 94.73% and 100% and for partial thickness rotator cuff tears 76.92% and 100%. Ultrasonography has 100% sensitivity and specificity for detection of supraspinatus full thickness tear. For supraspinatus partial thickness tear, sensitivity and specificity was 88

  13. Fatty liver diagnostic from medical examination to analyze the accuracy between the abdominal ultrasonography and liver hounsfield units

    International Nuclear Information System (INIS)

    Oh, Wang Kyun; Kim, Sang Hyun

    2017-01-01

    In abdominal Ultrasonography, the fatty liver is diagnosed through hepatic parenchymal echo increased parenchymal density and unclear blood vessel boundary, and according to many studies, abdominal Ultrasonography has 60 ∼ 90% of sensitivity and 84 ∼ 95% of specificity in diagnosis of fatty liver, but the result of Ultrasonography is dependent on operators, so there can be difference among operators, and quantitative measurement of fatty infiltration is impossible. Among examinees who same day received abdominal Ultrasonography and chest computed tomography (CT), patients who were diagnosed with a fatty liver in the Ultrasonography were measured with liver Hounsfield Units (HU) of chest CT imaging to analyze the accuracy of the fatty liver diagnosis. Among 720 subject examinees, those who were diagnosed with a fatty liver through abdominal Ultrasonography by family physicians were 448, which is 62.2%. The result of Liver HU measurement in the chest CT imaging of those who were diagnosed with a fatty liver showed that 175 out of 720 had the measured value of less than 40 HU, which is 24.3%, and 173 were included to the 175 among 448 who were diagnosed through Ultrasonography, so 98.9% corresponded. This indicates that the operators' subjective ability has a great impact on diagnosis of lesion in Ultrasonography diagnosis of a fatty liver, and that in check up chest CT, under 40 HU in the measurement of Liver HU can be used for reference materials in diagnosis of a fatty liver

  14. Comparison of the diagnostic value of ultrasonography and standing radiography for pelvic-femoral disorders in horses.

    Science.gov (United States)

    Geburek, Florian; Rötting, Anna K; Stadler, Peter M

    2009-04-01

    To assess agreement between ultrasonography (transcutaneous and transrectal) and standing radiography in horses with fractures in the pelvic region and disorders of the coxofemoral joint. Case series. Warmblood horses (n=23) and 2 ponies. Medical records (1999-2008) of equids with pelvic or coxofemoral disorders that had pelvic radiography and ultrasonography were retrieved and results of both techniques compared. Radiography and ultrasonography each identified equal numbers of fractures of the tuber coxa (n=4), ilial shaft (2), ischium (3), femoral neck (2), and osteoarthritis/osis of the coxofemoral joint (6). Fractures of the ilial wing (4) were only identified by ultrasonography not by standing radiography. Of 9 acetabular fractures, 3 were identified on radiographs only, 5 were identified with both modalities. One pubic fracture was identified using ultrasonography and radiography. One acetabular and 1 pubic fracture were only diagnosed on necropsy. We found reasonable agreement (73%; 24/33) between ultrasonography and standing radiography for diagnosis of pelvic-femoral disorders. Ultrasonography was more useful for ilial wing fractures and radiography for acetabular fractures. Ultrasonography is a rapid, safe imaging technique for detecting disorders of the pelvic region with a high diagnostic yield and is a preferred initial approach in horses with severe hindlimb lameness.

  15. Fatty liver diagnostic from medical examination to analyze the accuracy between the abdominal ultrasonography and liver hounsfield units

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Wang Kyun [Dept. of Radiology, Cheongju Medical Center, Cheongju (Korea, Republic of); Kim, Sang Hyun [Dept. of Radiological Science, Shinhan University, Uijeongbu (Korea, Republic of)

    2017-06-15

    In abdominal Ultrasonography, the fatty liver is diagnosed through hepatic parenchymal echo increased parenchymal density and unclear blood vessel boundary, and according to many studies, abdominal Ultrasonography has 60 ∼ 90% of sensitivity and 84 ∼ 95% of specificity in diagnosis of fatty liver, but the result of Ultrasonography is dependent on operators, so there can be difference among operators, and quantitative measurement of fatty infiltration is impossible. Among examinees who same day received abdominal Ultrasonography and chest computed tomography (CT), patients who were diagnosed with a fatty liver in the Ultrasonography were measured with liver Hounsfield Units (HU) of chest CT imaging to analyze the accuracy of the fatty liver diagnosis. Among 720 subject examinees, those who were diagnosed with a fatty liver through abdominal Ultrasonography by family physicians were 448, which is 62.2%. The result of Liver HU measurement in the chest CT imaging of those who were diagnosed with a fatty liver showed that 175 out of 720 had the measured value of less than 40 HU, which is 24.3%, and 173 were included to the 175 among 448 who were diagnosed through Ultrasonography, so 98.9% corresponded. This indicates that the operators' subjective ability has a great impact on diagnosis of lesion in Ultrasonography diagnosis of a fatty liver, and that in check up chest CT, under 40 HU in the measurement of Liver HU can be used for reference materials in diagnosis of a fatty liver.

  16. The Effectiveness of Ultrasonography in Detecting Emergent Pediatric Pathologies and Requirement for Additional Imaging Techniques: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    Betül Tiryaki Baştuğ

    2018-04-01

    Full Text Available Introduction: In emergency cases, ultrasonography is used in guiding resuscitation, to provide procedural guidance, and confirm a clinical diagnosis. In addition, it may prevent unnecessary exposure of the patient to ionizing radiation and risks caused by transporting the patient away from monitoring. This paper aimed to evaluate the effectiveness of ultrasonography in detecting emergent pediatric pathologies in a state hospital radiology unit, and to identify whether additional imaging techniques, such as computed tomography, were required. Methods: This study was designed as a retrospective investigation. A group of 536 patients were randomly selected from 1.401 pediatric patients who underwent ultrasonography for non-traumatic emergent pathologies between 2015 and 2016. Results: Of the 536 patients, 46 were diagnosed with appendicitis, 14 with pathologies of the urinary system, 1 with ileus, 29 with mesenteric lymphadenitis, 4 with intussusception, 3 with ovarian cyst rupture, 1 with ovarian torsion, and 32 with scrotal pathologies. Computed tomography was performed for 20 patients. Ureteral calculi and appendicitis were confirmed by computed tomography in 5 and 14 patients, respectively, after being identified as secondary findings by ultrasonography. In 1 patient, ileus was verified by computed tomography. The sensitivity of ultrasonography was determined to be 85.7%. Only 14% of patients were not given definite pathological diagnoses by ultrasonography alone. Subsequent computed tomography for verifying secondary findings detected by ultrasonography was essential in only 20 patients. Conclusion: Our results promote the use of ultrasonography as the initial imaging test for evaluating pediatric patients with suspected emergency pathologies.

  17. Gestational ultrasonography and Dopplerfluxometry in capuchin monkeys (Sapajus apella) zoometric.

    Science.gov (United States)

    Miranda, S A; Leão, D L; Oliveira, K G; Sodré, I S; Domingues, S F S

    2018-03-01

    The objectives of the current study were as follows: 1) to evaluate blood flow in the uterine (UA) and umbilical (Uma) arteries in pregnant capuchin monkeys by measuring the resistive index (RI) and pulsatility index (PI); 2) to determine the presence or absence of the early diastolic notch and diastolic flow in the UA and Uma flow waveforms, respectively; 3) to perform conceptus echobiometry for fetal growth assessment during pregnancy; 4) to describe the moment that the fetal organs were initially observed; and 5) to determine when the diagnosis of fetal gender is possible. Seven healthy, sexually mature female Sapajus apella were examined in Weeks -20 to -1 before whelping (whelping Week 0). Triplex Doppler was used to assess the blood flow and fetal heart rate, and B-mode ultrasonography was used to assess the fetal organs and conceptus measurements, including the gestational sac latero-lateral longitudinal (LLL) and latero-lateral transversal (LLT), the crown rump length (CRL), biparietal diameter (BPD), occipito-frontal diameter (OFD), head circumference (HC), abdominal circumference (AC), femur length (FL) and fetal organ. All the pregnancies ended with a normal whelping and the birth of a live newborn. Prior to whelping, all conceptus dimensions increased significantly, whereas the RI and PI of both the UA and Uma decreased significantly. For the UA, the RI and PI were (mean ± SEM) 0.835 ± 0.017 and 2.157 ± 0.129, 0.808 ± 0.008 and 1.920 ± 0.041, and 0.761 ± 0.006 and 1.759 ± 0.036 on periods -3, -2 and -1, respectively. For the Uma, the RI and PI were 0.97 ± 0.01 and 2.50 ± 0.02 at Week -17 and were 0.64 ± 0.02 and 0.98 ± 0.04 at Week -1, respectively. The complete disappearance of the early diastolic notch in the UA, and the complete appearance of diastolic flow in the Uma occurred on Week -1 and Week -11, respectively. Linear regression analyses regarding the relationship of the weeks before whelping (WBW) with the

  18. Improvement of diagnostic accuracy, and clinical evaluation of computed tomography and ultrasonography for deep seated cancers

    International Nuclear Information System (INIS)

    Arimizu, Noboru

    1980-01-01

    Cancers of the liver, gallbladder, and pancreas which were difficult to be detected at an early stage were studied. Diagnostic accuracy of CT and ultrasonography for vesectable small cancers was investigated by the project team and coworkers. Only a few cases of hepatocellular carcinoma, cancer of the common bile duct, and cancer of the pancreas head, with the maximum diameter of 1 - 2 cm, were able to be diagnosed by CT. There seemed to be more false negative cases with small cancers of that size. The limit of the size which could be detected by CT was thought to be 2 - 3 cm. Similar results were obtained by ultrasonography. Cancer of the pancreas body with the maximum diameter of less than 3.5 cm could not be detected by both CT and ultrasonography. Diagnostic accuracy of CT for liver cancer was improved by selective intraarterial injection of contrast medium. Improvement of the quality of ultrasonograms was achieved through this study. Merits and demerits of CT and ultrasonography were also compared. (Tsunoda, M.)

  19. The Role of Ultrasonography in In-vitro Fertilization And Embryo ...

    African Journals Online (AJOL)

    Randomized controlled trials show that ultrasoundguided transfer techniques have better outcomes than the clinical touch technique in terms of on-going pregnancies and clinical pregnancies. Ultrasonography is now the key instrument for diagnosing and monitoring pregnancy following embryo transfer, biochemical ...

  20. Application of Intraoperative Ultrasonography for Guiding Microneurosurgical Resection of Small Subcortical Lesions

    International Nuclear Information System (INIS)

    Wang, Jia; Duan, Yun You; Liu, Xi; Wang, Yu; Gao, Guo Dong; Qin, Huai Zhou; Wang, Liang

    2011-01-01

    We wanted to evaluate the clinical value of intraoperative ultrasonography for real-time guidance when performing microneurosurgical resection of small subcortical lesions. Fifty-two patients with small subcortical lesions were involved in this study. The pathological diagnoses were cavernous hemangioma in 25 cases, cerebral glioma in eight cases, abscess in eight cases, small inflammatory lesion in five cases, brain parasite infection in four cases and the presence of an intracranial foreign body in two cases. An ultrasonic probe was sterilized and lightly placed on the surface of the brain during the operation. The location, extent, characteristics and adjacent tissue of the lesion were observed by high frequency ultrasonography during the operation. All the lesions were located in the cortex and their mean size was 1.3 ± 0.2 cm. Intraoperative ultrasonography accurately located all the small subcortical lesions, and so the neurosurgeon could provide appropriate treatment. Different lesion pathologies presented with different ultrasonic appearances. Cavernous hemangioma exhibited irregular shapes with distinct margins and it was mildly hyperechoic or hyperechoic. The majority of the cerebral gliomas displayed irregular shapes with indistinct margins, and they often showed cystic and solid mixed echoes. Postoperative imaging identified that the lesions had completely disappeared, and the original symptoms of all the patients were significantly alleviated. Intraoperative ultrasonography can help accurately locate small subcortical lesions and it is helpful for selecting the proper approach and guiding thorough resection of these lesions.

  1. Application of Intraoperative Ultrasonography for Guiding Microneurosurgical Resection of Small Subcortical Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jia; Duan, Yun You; Liu, Xi; Wang, Yu; Gao, Guo Dong; Qin, Huai Zhou; Wang, Liang [Tangdu Hospital of the Fourth Military Medicine University, Xi an (China)

    2011-10-15

    We wanted to evaluate the clinical value of intraoperative ultrasonography for real-time guidance when performing microneurosurgical resection of small subcortical lesions. Fifty-two patients with small subcortical lesions were involved in this study. The pathological diagnoses were cavernous hemangioma in 25 cases, cerebral glioma in eight cases, abscess in eight cases, small inflammatory lesion in five cases, brain parasite infection in four cases and the presence of an intracranial foreign body in two cases. An ultrasonic probe was sterilized and lightly placed on the surface of the brain during the operation. The location, extent, characteristics and adjacent tissue of the lesion were observed by high frequency ultrasonography during the operation. All the lesions were located in the cortex and their mean size was 1.3 {+-} 0.2 cm. Intraoperative ultrasonography accurately located all the small subcortical lesions, and so the neurosurgeon could provide appropriate treatment. Different lesion pathologies presented with different ultrasonic appearances. Cavernous hemangioma exhibited irregular shapes with distinct margins and it was mildly hyperechoic or hyperechoic. The majority of the cerebral gliomas displayed irregular shapes with indistinct margins, and they often showed cystic and solid mixed echoes. Postoperative imaging identified that the lesions had completely disappeared, and the original symptoms of all the patients were significantly alleviated. Intraoperative ultrasonography can help accurately locate small subcortical lesions and it is helpful for selecting the proper approach and guiding thorough resection of these lesions.

  2. Improvement of diagnostic accuracy, and clinical evaluation of computed tomography and ultrasonography for deep seated cancers

    Energy Technology Data Exchange (ETDEWEB)

    Arimizu, N [Chiba Univ. (Japan). School of Medicine

    1980-06-01

    Cancers of the liver, gallbladder, and pancreas which were difficult to be detected at an early stage were studied. Diagnostic accuracy of CT and ultrasonography for resectable small cancers was investigated by the project team and co-workers. Only a few cases of hepatocellular carcinoma, cancer of the common bile duct, and cancer of the pancreas head, with the maximum diameter of 1 - 2 cm, were able to be diagnosed by CT. There seemed to be more false negative cases with small cancers of that size. The limit of the size which could be detected by CT was thought to be 2 - 3 cm. Similar results were obtained by ultrasonography. Cancer of the pancreas body with the maximum diameter of less than 3.5 cm could not be detected by both CT and ultrasonography. Diagnostic accuracy of CT for liver cancer was improved by selective intraarterial injection of contrast medium. Improvement of the quality of ultrasonograms was achieved through this study. Merits and demerits of CT and ultrasonography were also compared.

  3. Assessment of Oropharyngeal Dysphagia in Patients With Parkinson Disease: Use of Ultrasonography.

    Science.gov (United States)

    Oh, Eun Hyun; Seo, Jin Seok; Kang, Hyo Jung

    2016-04-01

    To compare tongue thickness, the shortest hyoid-thyroid approximation (distance between the hyoid bone and thyroid cartilage), and the time interval between the initiation of tongue movement and the time of the shortest hyoid-thyroid approximation, by using ultrasonography in healthy controls and patients with Parkinson disease (PD). Healthy controls and PD patients with dysphagia were compared. Ultrasonography was performed 3 times for the evaluation of tongue thickness, the shortest hyoid-thyroid approximation, and the time between the initiation of tongue movement and the shortest hyoid-thyroid approximation. A total of 24 healthy controls and 24 PD patients with dysphagia were enrolled. No significant differences were demonstrated between the two groups for the shortest hyoid-thyroid approximation (controls, 1.19±0.34 cm; PD patients, 1.37±0.5 cm; p=0.15) and tongue thickness (controls, 4.42±0.46 cm; PD patients, 4.27±0.51 cm; p=0.3). In contrast, the time to the shortest hyoid-thyroid approximation was significantly different between the two groups (controls, 1.53±0.87 ms; PD patients, 2.4±1.4 ms, p=0.048). Ultrasonography can be useful in evaluating dysphagia in patients with PD by direct visualization and measurement of the hyoid bone. Moreover, ultrasonography might contribute to a greater understanding of the pathophysiology of dysphagia in PD.

  4. Follow-up of renal and mesenteric artery revascularization with duplex ultrasonography

    Science.gov (United States)

    Taylor, David C.; Houston, Gordon T.M.; Anderson, Caroline; Jameson, Margot; Popatia, Shelley

    1996-01-01

    Objective To evaluate the long-term anatomic results of renal revascularization procedures using duplex ultrasonography. Design A case series. Setting A university-affiliated hospital. Patients Twenty-five patients who had undergone renal percutaneous transluminal angioplasty (PTA) (18 arteries), renal bypass (10 arteries) and mesenteric bypass (6 arteries). The mean follow-up was 22 months (range from 3 to 48 months) for those who underwent renal PTA, 23 months (range from 1.5 to 70 months) for those who underwent renal bypass and 34 months (range from 8 to 144 months) for those who underwent mesenteric bypass. Main Outcome Measures Patency rates for the three procedures as assessed by duplex ultrasonography. Results Duplex ultrasonography demonstrated patency without stenosis after renal and mesenteric artery revascularization in 14 arteries subjected to renal PTA, 9 arteries subjected to renal bypass and 6 arteries subjected to mesenteric bypass. Three arteries that had renal PTA had recurrent vessel stenosis and one had occlusion. One artery that had renal bypass showed occlusion. Conclusions Renal PTA, renal bypass and mesenteric bypass are durable procedures at 2 years of follow-up, and duplex ultrasonography is a valuable method for assessing the patency of arteries after renal and mesenteric revascularization. PMID:8599785

  5. Ultrasonography of the larynx for diagnosis of the vocal folds mobility impairment

    Directory of Open Access Journals (Sweden)

    Petr S. Vetshev

    2017-03-01

    Full Text Available Purpose. To study a possibility of performance and diagnostic accuracy of ultrasonography (US of a larynx in identification of motility disorders of VF (vocal folds in comparison with the laryngoscope which is traditionally applied for this purpose. Materials and methods. According to the objectives of the study, two patient groups were formed. In first group of patients (n = 466 we studied acceptability of ultrasonografy to discriminate various laryngeal structures. In second group of patient (n = 432 we evaluated the diagnostic accuracy of ultrasonography in point of detection of vocal muscles paresis. Results. Laryngeal structures were available to examination by ultrasound (without taking in account age and sex in 92.7% of patients. Two patterns have been identified in the course of this part of the study: deterioration of visibility of the vocal folds with increasing patient age and better visibility of the vocal folds in women than in men. According to the comparative analysis, ultrasonography accuracy rate (in those patients who had had clearly visible vocal folds during ultrasonography did not differ from that during videolaryngoscopy. Conclusion. During the conducted research it was found that the US of the larynx is an effective and perspective method for detection of a paresis of VF with sensitivity and specificity 93,55% and 100% respectively. Among those patients who' VF are available to ultrasound evaluation the accuracy of method is comparable with a videolaryngoscopy and can be used with success in daily work of units of endocrine surgery.

  6. Use of musculoskeletal ultrasonography in the diagnosis of pes anserine tendinitis: a case report.

    Science.gov (United States)

    Valley, V T; Shermer, C D

    2001-01-01

    A 45-year-old woman presented to the Emergency Department with a chief complaint of acute, nontraumatic medial knee pain. Musculoskeletal ultrasonography was performed, and the diagnosis of pes anserine tendinitis was elucidated. A discussion of this clinical entity, the characteristic ultrasonographic findings, and therapy follow in this case report.

  7. Laparoscopic ultrasonography--a method for staging of upper gastrointestinal cancer

    DEFF Research Database (Denmark)

    Durup Scheel-Hincke, J; Mortensen, M B; Pless, T

    1999-01-01

    Laparoscopic ultrasonography (LUS) is a method that can be useful in the staging of upper gastrointestinal cancer. Dedicated transducers are available, and preliminary studies have proposed indications for the use of LUS staging of hepatic, esophageal, gastric, and pancreatic cancer disease. In t...

  8. Ultrasonography, computed tomography, and cholescintigraphy in suspected obstructive jaundice--a prospective comparative study

    DEFF Research Database (Denmark)

    Matzen, P; Malchow-Møller, A; Brun, B

    1983-01-01

    In order to compare their capacity to visualize the bile ducts, ultrasonography, computed tomography, and cholescintigraphy were performed in 56 consecutive jaundiced patients in whom extrahepatic cholestasis was clinically suspected. The predictions as to the patency of the large bill ducts were...

  9. Ultrasonography and magnetic resonance imaging in early rheumatoid arthritis: recent advances

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Døhn, Uffe M; Ejbjerg, Bo J

    2006-01-01

    Efficient methods for diagnosis, monitoring, and prognostication are essential in early rheumatoid arthritis. Data on the value of ultrasonography and MRI are accumulating rapidly, fueling their increasing use in early rheumatoid arthritis. This review focuses on recent advances in the clinical...

  10. Diagnosis of fibroadenoma and breast cancer: ultrasonography vs. X-ray mammography

    Energy Technology Data Exchange (ETDEWEB)

    Song, Jong Gi; Im, Jung gi; Choi, Byung Ihn; Kim, Choo Wan [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1993-12-15

    To evaluate the clinical value of ultrasonography in the diagnosis of fibroadenoma and carcinoma as compared with mammography, we performed a blind retrospective analysis of 85 sonograms and 40 mammograms of 85 breasts that were proved pathologically to have diseases. The lesions included 30 ductal carcinomas, 29 fibroadenomas, 14mammary dysplasias, 2 medullary carcinomas, 1 intraductal papillary carcinoma, and 9 cases of other pathology. The sonograms were reviewed in regards to the border, shape and internal echo pattern of the lesion and the shadows from the margin of the lesion. The mammograms were reviewed in regards to the parenchymal pattern, shape, margin,and calcification of the lesion. The accuracy, sensitivity, and specificity of mammography and ultrasonography in the diagnosis of fibroadenoma were 77%/92%, 40%/93%, and 100%/92%, respectively. The accuracy, sensitivity, and specificity of mammography and ultrasonography in the diagnosis of carcinoma were 85%/85%, 76%/82%, and 91%/86%,respectively. Ultrasonography is more accurate and more sensitive than mammography in the diagnosis offibroadenoma, but not in the diagnosis of carcinoma

  11. Is salivary gland ultrasonography a useful tool in Sjogren's syndrome? A systematic review

    NARCIS (Netherlands)

    Jousse-Joulin, Sandrine; Milic, Vera; Jonsson, Malin V.; Plagou, Athena; Theander, Elke; Luciano, Nicoletta; Rachele, Pascale; Baldini, Chiara; Bootsma, Hendrika; Vissink, Arjan; Hocevar, Alojzija; De Vita, Salvatore; Tzioufas, Athanasios G.; Alavi, Zarin; Bowman, Simon J.; Devauchelle-Pensec, Valerie

    Objective. Ultrasonography (US) is a sensitive tool in the diagnosis of major salivary gland abnormalities in primary Sjogren's syndrome (pSS). The aim of this systematic review was to assess the metric properties of this technique. Methods. PUBMED and EMBASE databases were searched. All

  12. Prediction of late failure after medical abortion from serial beta-hCG measurements and ultrasonography

    DEFF Research Database (Denmark)

    Rørbye, C; Nørgaard, M; Nilas, Lisbeth

    2004-01-01

    BACKGROUND: Surgical treatment of failed medical abortion may be performed several weeks after initiation of the abortion. There are no recognized methods for early identification of these late failures. We assessed the prognostic values of beta-hCG and ultrasonography in predicting late failure ...

  13. Dynamic Contrast-Enhanced Magnetic Resonance Enterography and Dynamic Contrast-Enhanced Ultrasonography in Crohn's Disease

    DEFF Research Database (Denmark)

    Wilkens, Rune; Peters, David A; Nielsen, Agnete Hedemann

    2017-01-01

    Purpose e Cross-sectional imaging methods are important for objective evaluationof small intestinal inflammationinCrohn'sdisease(CD).The primary aim was to compare relative parameters of intestinal perfusion between contrast-enhanced ultrasonography (CEUS) and dynamic contrast-enhanced magnetic...

  14. Ultrasonography and magnetic resonance imaging in the diagnosis of Morton's neuroma.

    Science.gov (United States)

    Fazal, Muhammad Ali; Khan, Ishrat; Thomas, Cherian

    2012-01-01

    Magnetic resonance imaging (MRI) and ultrasonography are used widely for the diagnosis of Morton's neuroma. The aim of this study was to assess the accuracy of these two modalities as diagnostic tools in Morton's neuroma. Fifty feet of 47 consecutive patients (39 women and 8 men; mean age, 46 years; age range, 36-64 years) who presented between January 1, 2005, and June 30, 2008, were included in the study. Twenty-five feet were investigated with ultrasonography and 25 with MRI. Morton's neuroma was confirmed surgically and histologically in all of the patients. A Student unpaired t test was applied. Twenty-two MRIs were diagnostic (sensitivity, 88%). Three patients with negative MRI findings underwent ultrasonography and were found to have a neuroma smaller than 5 mm. Twenty-four ultrasound scans demonstrated the neuroma (sensitivity, 96%), with five neuromas being smaller than 5 mm. Ultrasonography has a slightly higher sensitivity in the diagnosis of Morton's neuroma, particularly of neuromas smaller than 5 mm, and should be the preferred imaging modality in suspected cases, and MRI should be reserved for cases with equivocal diagnosis.

  15. Diagnosis of fibroadenoma and breast cancer: ultrasonography vs. X-ray mammography

    International Nuclear Information System (INIS)

    Song, Jong Gi; Im, Jung gi; Choi, Byung Ihn; Kim, Choo Wan

    1993-01-01

    To evaluate the clinical value of ultrasonography in the diagnosis of fibroadenoma and carcinoma as compared with mammography, we performed a blind retrospective analysis of 85 sonograms and 40 mammograms of 85 breasts that were proved pathologically to have diseases. The lesions included 30 ductal carcinomas, 29 fibroadenomas, 14mammary dysplasias, 2 medullary carcinomas, 1 intraductal papillary carcinoma, and 9 cases of other pathology. The sonograms were reviewed in regards to the border, shape and internal echo pattern of the lesion and the shadows from the margin of the lesion. The mammograms were reviewed in regards to the parenchymal pattern, shape, margin,and calcification of the lesion. The accuracy, sensitivity, and specificity of mammography and ultrasonography in the diagnosis of fibroadenoma were 77%/92%, 40%/93%, and 100%/92%, respectively. The accuracy, sensitivity, and specificity of mammography and ultrasonography in the diagnosis of carcinoma were 85%/85%, 76%/82%, and 91%/86%,respectively. Ultrasonography is more accurate and more sensitive than mammography in the diagnosis offibroadenoma, but not in the diagnosis of carcinoma

  16. Ability of subtraction and dynamic MR imaging to detect breast tumors. Comparison with ultrasonography and mammography

    International Nuclear Information System (INIS)

    Terao, Eri; Takeuchi, Hiroaki; Iwamura, Akira; Murakami, Yoshitaka; Harada, Junta; Tada, Shinpei

    1994-01-01

    We evaluated the ability of subtraction and dynamic MR imaging to accurately detect breast tumors. Sixty-five breast carcinomas and 24 fibroadenomas were examined by an SE pulse sequence using a 0.2 Tesla unit. Subtraction MR images were obtained every minute during dynamic study with Gd-DTPA. Almost all breast tumors were seen as very bright masses, and the margin of the mass was clearly demonstrated on subtraction MR images. Breast carcinomas and fibroadenomas showed characteristic time-intensity curves on dynamic study. Time-intensity curves of the early peak type and plateau type were seen in 97% of breast carcinomas, while the gradually increasing type was seen in 92% of fibroadenomas. The detectability of breast carcinoma was 98% by MRI, 98% by ultrasonography, and 87% by mammography. That of fibroadenoma was 95% by MRI, 91% by ultrasonography and 60% by mammography. Sensitivity and specificity for breast carcinoma were 98% and 92% for MRI and 97% and 71% for ultrasonography. For fibroadenoma, they were 96% and 98% for MRI and 89% and 92% for ultrasonography. (author)

  17. Ability of subtraction and dynamic MR imaging to detect breast tumors. Comparison with ultrasonography and mammography

    Energy Technology Data Exchange (ETDEWEB)

    Terao, Eri; Takeuchi, Hiroaki; Iwamura, Akira; Murakami, Yoshitaka; Harada, Junta; Tada, Shinpei (Jikei Univ., Tokyo (Japan). School of Medicine)

    1994-09-01

    We evaluated the ability of subtraction and dynamic MR imaging to accurately detect breast tumors. Sixty-five breast carcinomas and 24 fibroadenomas were examined by an SE pulse sequence using a 0.2 Tesla unit. Subtraction MR images were obtained every minute during dynamic study with Gd-DTPA. Almost all breast tumors were seen as very bright masses, and the margin of the mass was clearly demonstrated on subtraction MR images. Breast carcinomas and fibroadenomas showed characteristic time-intensity curves on dynamic study. Time-intensity curves of the early peak type and plateau type were seen in 97% of breast carcinomas, while the gradually increasing type was seen in 92% of fibroadenomas. The detectability of breast carcinoma was 98% by MRI, 98% by ultrasonography, and 87% by mammography. That of fibroadenoma was 95% by MRI, 91% by ultrasonography and 60% by mammography. Sensitivity and specificity for breast carcinoma were 98% and 92% for MRI and 97% and 71% for ultrasonography. For fibroadenoma, they were 96% and 98% for MRI and 89% and 92% for ultrasonography. (author).

  18. Diagnostic value of liver scintigraphy, computed tomography and ultrasonography of fatal hepatitis

    International Nuclear Information System (INIS)

    Komori, Hideshi; Hirasa, Masahiro; Ibuki, Yasuyoshi

    1983-01-01

    The purpose of this study was investigate the diagnostic value of liver scintigraphy, computed tomography (CT) and ultrasonography in acute hepatic failure, subacute hepatitis and acute hepatitis. By scintigraphy low uptake in the liver and high uptake in the spleen and bone marrow were observed in hepatic failure. However, uneven liver edge and heterogenous RI destribution were not corresponded to massive necrosis. In fulminant hepatitis, liver size and other findings were variable in patient by patient. But in subacute hepatitis, the findings were typical. The finding of left lobe swelling was observed in a half of patients with acute hepatic failure based on chronic hepatitis. Localized low density area by the CT was detected in most of the cases of subacute hepatitis, and acute hepatitis with submassive hepatic necrosis. But in fulminant hepatitis, that was rare. In these cases, irregular and strong lesion was also obsurved by ultrasonography. These findings by the CT and ultrasonography were corresponded to massive necrosis histrogically ultrasonography revealed narrowing of hepatic vein in fatal hepatitis. Localized low density area by the CT in subacute hepatitis was shown surrounding hepatic vein. We conclude that development of massine hepatic necrosis concern to secondary hepatic ischemia. (author)

  19. Liver metastases: Sulphur hexafluoride-enhanced ultrasonography for lesion detection: a systematic review

    NARCIS (Netherlands)

    Cabassa, Paolo; Bipat, Shandra; Longaretti, Laura; Morone, Mario; Maroldi, Roberto

    2010-01-01

    This is a systematic review to evaluate the accuracy of contrast-enhanced ultrasonography (CEUS) performed with "SonoVue" (sulphur hexafluoride) in the detection of hepatic metastases. The MEDLINE, EMBASE and COCHRANE Databases were searched, regardless of language, for relevant articles published

  20. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    International Nuclear Information System (INIS)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D'Ippolito, Giuseppe; Colleoni, Ramiro

    2008-01-01

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  1. Ultrasonography to quantify hepatic fat content : Validation by H-1 Magnetic Resonance Spectroscopy

    NARCIS (Netherlands)

    Edens, M.A.; van Ooijen, P.M.A.; Post, W.J.; Haagmans, M.J.F.; Kristanto, W.; Sijens, P.E.; van der Jagt, E.J.; Stolk, R.P.

    2009-01-01

    An abundance of fat stored within the liver, or steatosis, is the beginning of a broad hepatological spectrum, usually referred to as fatty liver disease (FLD). For studies on FLD, quantitative hepatic fat ultrasonography would be an appealing study modality. Objective of this study was to develop a

  2. Diagnosis of thromboembolic disease: combined ventilation perfusion lung scan and compression ultrasonography

    International Nuclear Information System (INIS)

    Dadparvar, S.; Woods, K.; Magno, R.M.; Sabatino, J. C.; Patil, S.; Dou, Y.

    2002-01-01

    The clinical management of pulmonary embolism and deep venous thrombosis of the legs are similar and require prolonged anticoagulation therapy. The standard diagnostic approach in patients suspected of pulmonary embolism is ventilation-perfusion (V/Q) lung scan and compression ultrasonography to detect deep venous thrombosis. This retrospective study analyzed the role of V Q lung scan and compression ultrasonography in detection of thromboembolic disease. One hundred-twenty consecutive patients (65 female, 55 male) age range 18-95 (mean age 60.7) suspected for pulmonary embolism underwent concomitant V/Q lung scan and compression ultrasonography of the lower extremities. The clinical and radiographic correlation was performed. Of patients with non-diagnostic (low or intermediate probability ) lung scans, 15.4 % (14/91) received anticoagulation therapy for pulmonary embolism. This patients had either high pre-clinical suspicion for PE or underwent pulmonary arterio gram. However, there was an additional 7 % (7/91) increase in the number of patients who received anticoagulation therapy based on the results of ultrasound with confidence interval (3 %-16 %). We conclude that V/Q lung scan is a more sensitive examination for thromboembolic disease, and has a high negative predictive value. Ultrasonography of lower extremities demonstrated higher specificity and positive value. Among patients with non-diagnostic lung scan, the detection rate of thromboembolic disease is improved with addition of ultrasound

  3. Ultrasonography, scintigraphy and computerized tomography in the investigation of the biliary tract

    International Nuclear Information System (INIS)

    Elie, G.; Drouillard, J.; Leccia, F.; Bergeron, J.-L.; Ducassou, D.; Tarvernier, J.

    1981-01-01

    New methods of investigation of the gallbladder and jaundice, without discomfort for the patients, have changed the usual algorythms. The main investigation is ultrasonography, without irradiation, not expensive, it is the best way to appreciate the dilatation of the biliary tract [fr

  4. Imaging in early rheumatoid arthritis: roles of magnetic resonance imaging, ultrasonography, conventional radiography and computed tomography

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Ejbjerg, Bo; Szkudlarek, Marcin

    2005-01-01

    Efficient methods for diagnosis, monitoring and prognostication are essential in early rheumatoid arthritis (RA). While conventional X-rays only visualize the late signs of preceding disease activity, there is evidence for magnetic resonance imaging (MRI) and ultrasonography being highly sensitiv...

  5. Serial cranial ultrasonography or early MRI for detecting preterm brain injury?

    NARCIS (Netherlands)

    Plaisier, Annemarie; Raets, Marlou M A; Ecury-Goossen, Ginette M; Govaert, Paul; Feijen-Roon, Monique; Reiss, Irwin K M; Smit, Liesbeth S; Lequin, Maarten H; Dudink, Jeroen

    OBJECTIVE: To investigate detection ability and feasibility of serial cranial ultrasonography (CUS) and early MRI in preterm brain injury. DESIGN: Prospective cohort study. SETTING: Level III neonatal intensive care unit. PATIENTS: 307 infants, born below 29 weeks of gestation. METHODS: Serial CUS

  6. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: ar.leao@uol.com.br; Colleoni, Ramiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Gastroenterologia

    2008-09-15

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  7. Implementation of laparoscopic splenectomy in children and the incidence of portal vein thrombosis diagnosed by ultrasonography

    NARCIS (Netherlands)

    Oomen, Matthijs W. N.; Bakx, Roel; van Minden, Minke; van Rijn, Rick R.; Peters, Marjolein; Heij, Hugo A.

    2013-01-01

    The aim of this study is to evaluate if symptomatic or asymptomatic PVT, as diagnosed with ultrasonography (US), occurs more often in children after the introduction and implementation of LS compared to open splenectomy. A retrospective cohort of 76 splenectomized patients for benign hematological

  8. Use of ultrasonography to identify late-stage maturity in rainbow trout Oncorhynchus mykiss

    Science.gov (United States)

    Morphometric measurements by ultrasonography has been used to determine gonad and follicle size in many species of fish for purposes of identifying sex and estimating stage of maturation. We have been using a portable ultrasound system (SonoSite MicroMaxx, L25e/13-6 MHz transducer) to identify fem...

  9. Ultrasonography of occipital arteries to diagnose giant cell arteritis: a case series and literature review.

    Science.gov (United States)

    Pinnell, Jonathan; Tiivas, Carl; Perkins, Phillip; Blake, Tim; Saravana, Shanmugam; Dubey, Shirish

    2018-02-01

    We describe four cases of giant cell arteritis (GCA) that presented with occipital headache in the last 6 months. Typical ultrasound features of GCA were found in the occipital arteries which helped to confirm the diagnosis. One patient had already suffered significant visual loss by the time the diagnosis was made, reflecting the similarity in prognosis to the more typical GCA patients. These cases prompted a review of the literature to evaluate the evidence regarding the use of occipital artery ultrasonography in the investigation of GCA. We searched PubMed, Google Scholar and Web of Science and identified 17 papers but only four of these were relevant studies. The studies available show that typical features of GCA can be detected in the occipital arteries using ultrasonography. They also suggest that ultrasonography can detect changes in the occipital arteries when temporal arteries are not involved. However, occipital artery abnormalities were less common than temporal artery abnormalities in GCA. We advocate maintaining a high index of suspicion for GCA in patients presenting with atypical features, such as occipital headache. Ultrasonography has a vital role to play in the diagnosis of these patients. We recommend priority imaging of the affected area to facilitate prompt and accurate diagnosis of GCA, especially when atypical vessels are involved.

  10. Guiding histological assessment of uterine lesions using 3D in vitro ultrasonography and stereotaxis

    DEFF Research Database (Denmark)

    Vandermeulen, Liselore; Cornelis, Ann; Rasmussen, Christina Kjærgaard

    2017-01-01

    , the uterus was re-evaluated by 3D in vitro ultrasonography and in vitro gel instillation sonography (iGIS). The lesion of interest was pinpointed by inserting an intramuscular injection needle using a free-hand 2D-ultrasound guided technique to focus the macroscopic and the microscopic examination...

  11. Brain ultrasonography findings in neonates with exposure to cocaine during pregnancy

    NARCIS (Netherlands)

    van Huis, M.; van Kempen, A.A.M.W.; Peelen, M.; Timmers, M.; Boer, K.; Smit, B.J.; van Rijn, R.R.

    2009-01-01

    BACKGROUND: Cocaine exposure during pregnancy has been reported to have detrimental effects on the fetus. OBJECTIVE: To describe the findings on cranial ultrasonography (CUS) as part of a neonatal screening programme for exposed neonates. MATERIALS AND METHODS: The study was a semiprospective

  12. Current relevance of cervical ultrasonography in staging cancer of the esophagus and gastroesophageal junction

    NARCIS (Netherlands)

    Schreurs, Liesbeth; Verhoef, C.C.; van der Jagt, E.J.; van Dam, G.M.; Groen, H.; Plukker, J.T.

    Purpose: To evaluate the value of external ultrasonography (US) of the neck in current dedicated preoperative staging of patients with cancer of the esophagus and gastroesophageal junction (GEJ). Materials and methods: We analyzed 180 consecutive patients (154 men, 26 women, and mean age 63 (38-84)

  13. Diagnosis of ovarian tumors by ultrasonography and x-ray CT

    International Nuclear Information System (INIS)

    Watanabe, Hiromu

    1986-01-01

    A drawback in ultrasonography, an indispensable technique in imaging ovarian malignancies, is that it sometimes shows false positive for benign tumors including dermoid cyst and ovarian endometriosis. To overcome this, the concurrent use of X-Ray CT seems warrantable and this led us to carry out the study summarized below. CT was carried out on 268 of 322 ovarian disease cases which had undergone ultrasonography. The results obtained were as follows. Sensitivity of ultrasonography and CT in ovarian malignancies were 82 % and 88 % respectively. Of the cases subjected to both techniques, those who were deemed false positive were 39 in ultrasonography and 12 in CT. Ultrasonographic imagings of dermoid cyst and ovarian endometriosis were classified on the basis of their patterns. The results obtained revealed that those in which it was difficult to discriminate the image from ovarian malignancy were types V and VI in dermoid cyst and type III-C in ovarian endometriosis. In both dermoid cyst and ovarian endometriosis, nearly a 100 % accuracy rate was obtainable with CT for diagnosis of benign tumors. This strongly suggested that concurrent use of CT was required, in diagnosing ovarian diseases with the V or VI and III-C patterns referred to above. (author)

  14. Screening Performance Characteristic of Ultrasonography and Radiography in Detection of Pleural Effusion; a Meta-Analysis.

    Science.gov (United States)

    Yousefifard, Mahmoud; Baikpour, Masoud; Ghelichkhani, Parisa; Asady, Hadi; Shahsavari Nia, Kavous; Moghadas Jafari, Ali; Hosseini, Mostafa; Safari, Saeed

    2016-01-01

    The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. 12 studies were included in this meta-analysis (1554 subjects, 58.6% male). Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, pultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes.

  15. QUANTITATIVE MUSCLE ULTRASONOGRAPHY IN THE FOLLOW-UP OF JUVENILE DERMATOMYOSITIS

    NARCIS (Netherlands)

    Habers, G. Esther A.; van Brussel, Marco; Bhansing, Kavish J.; Hoppenreijs, Esther P.; Janssen, Anjo J. W. M.; van Royen-Kerkhof, Annet; Pillen, Sigrid

    2015-01-01

    Introduction: We explored the use of quantitative muscle ultrasonography (QMUS) for follow-up of juvenile dermatomyositis (JDM). Methods: Seven JDM patients were evaluated at diagnosis and 1, 3, 6, 12, and 24 months using the Childhood Myositis Assessment Scale (CMAS) and QMUS. Muscle thickness (MT)

  16. Ultrasonography in arthritis of the knee. A comparison with MR imaging

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Court-Payen, M; Gideon, P

    1995-01-01

    Ultrasonography (US) of the knee in gonarthritis was evaluated with gadolinium-DTPA-enhanced MR imaging as a reference. The study included 13 patients with gonarthritis, 2 patients with osteoarthritis and 5 healthy controls. Compared to MR, US identified 100% (12/12) of joint effusions, 100% (5...

  17. Diagnostic Accuracy of Ultrasonography in the Initial Evaluation of Patients with Penetrating Chest Trauma

    Directory of Open Access Journals (Sweden)

    Farhad Heydari

    2014-03-01

    Full Text Available Introduction: Traumatic chest injuries (TCI are one of the most common causes of referring to the emergency departments, with high mortality and disability. This study was designed to evaluate the diagnostic accuracy of ultrasonography versus chest X ray (CXR in detection of hemo-pneumothorax for patients suffering penetrating TCI. Methods: The present cross-sectional study was performed to evaluate the diagnostic accuracy of ultrasonography in penetrating TCI victims referred to the emergency department of Shahid Kashani and Alzahra hospitals of Isfahan, Iran, from July 2012 to June 2013. Bedside ultrasonography and plain CXR was done on arrival and three hours after admission. The results of ultrasonography and radiography were separately evaluated by an emergency medicine specialist and a radiologist, who were blind to the aims of the study. Then, sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and kappa coefficient was considered to evaluate the accuracy of ultrasonography. Results: In this research 64 patients with penetrating chest trauma were assessed (98.4% male. The mean age of them was 25.6±8.5 years (rang: 13-65. The plain radiography revealed the eight (12.5 % cases of pneumothorax and one (1.6% hemothorax. The findings of primary ultrasonography also showed the same number of hemo-pneumothorax. Sensitivity and specificity of primary ultrasound in diagnosis of pneumothorax were 100% (95% Cl: 60.7- 100 and 100.0% (95% Cl, 92.0% to 100.0% and in detection of hemothorax were 100% (95% Cl: 50.5-100 and 100% (95% Cl: 92.8-100, respectively. Sensitivity and specificity of ultrasound in the third hour were 100% (95% Cl: 31.3-100 and 100% (95% Cl: 91.4-100, respectively. Conclusion: Findings of the present study have shown that ultrasonography has an acceptable diagnostic accuracy in the initial assessment of patients with penetrating chest trauma. However, because of its dependency on operator

  18. The Efficacy of Magnetic Resonance Imaging and Color Doppler Ultrasonography in Diagnosis of Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    Behrooz Davachi

    2014-12-01

    Full Text Available Background and aims. Although salivary gland tumors are not very common, early diagnosis and treatment is crucial because of their proximity to vital organs, and therefore, determining the efficacy of new imaging procedures becomes important. This study aimed to evaluate the efficacy of magnetic resonance imaging (MRI and color doppler ultrasonography parameters in the diagnosis and differentiation of benign and malignant salivary gland tumors. Materials and methods. In this cross-sectional study, color doppler ultrasonography and MRI were performed for 22 patients with salivary gland tumor. Demographic data as well as MRI, color doppler ultrasonography, and surgical parameters including tumor site, signal in MRI images, ultrasound echo, tumor border, lymphadenopathy, invasion, perfusion, vascular resistance index (RI, vascular pulse index (PI were analyzed using Chi-square test, Fisher’s exact test, and independent ttest. Results. The mean age of patients was 46.59±13.97 years (8 males and 14 females. Patients with malignant tumors were older (P < 0.01. The most common tumors were pleomorphic adenoma (36.4%, metastasis (36.4%, and mucoepidermoid carcinoma (9%. Nine tumors (40.9% were benign and 13 (59.1% were malignant. The overall accuracy of MRI and color doppler ultrasonography in determining tumor site was 100% and 95%, respectively. No significant difference observed between RI and PI and the diagnosis of tumor. Conclusion. Both MRI and ultrasonography have high accuracy in the localization of tumors. Well-identified border was a sign of benign tumors. Also, invasion to adjacent structures was a predictive factor for malignancy.

  19. Screening Performance Characteristic of Ultrasonography and Radiography in Detection of Pleural Effusion; a Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Mahmoud Yousefifard

    2016-01-01

    Full Text Available Introduction: The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. Methods: An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. Results: 12 studies were included in this meta-analysis (1554 subjects, 58.6% male. Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, p<0.001 and its pooled specificity was calculated to be 0.98 (95% CI: 0.92-1.0; I2= 88.65, p<0.001, while sensitivity and specificity of chest radiography were 0.51 (95% CI: 0.33-0.68; I2= 91.76, p<0.001 and 0.91 (95% CI: 0.68-0.98; I2= 92.86, p<0.001, respectively. Sensitivity of ultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Conclusion: Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes.

  20. Anatomical features of plantar aponeurosis: cadaveric study using ultrasonography and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Moraes do Carmo, Clarissa Canella; Fonseca de Almeida Melao, Lina Isabel; Valle de Lemos Weber, Marcio Freitas; Trudell, Debra; Resnick, Donald [UCSD, Department of Radiology, San Diego, CA (United States); VA Healthcare System San Diego, La Jolla, CA (United States)

    2008-10-15

    Abnormalities of the plantar aponeurosis are commonly encountered in patients with subcalcaneal heel pain. Understanding normal anatomy is required to accurately diagnose some disorders of the foot. The purpose of our study was to describe the normal anatomy of the plantar aponeurosis, using ultrasonography and MRI with close anatomic correlation in cadavers. After MRI and ultrasonography of 10 cadaveric foot specimens, the thickness of the central and lateral portions of the plantar aponeurosis displayed by imaging studies was measured by three radiologists. One specimen was sectioned in the transverse plane, one in the coronal plane, one in the sagittal plane, and two in a sagittal oblique plane. Normal anatomy was identified and similar measurements of the plantar aponeurosis were also made. An average value was determined and a statistical analysis was accomplished. The calcaneal insertions of the plantar aponeurosis were better visualized than its distal portions with both MRI and ultrasonography. The measurements of the plantar aponeurosis made by three different radiologists were different, but without statistical significance. The average measurements for the central and lateral portions of the plantar aponeurosis with both imaging methods were different from each other because of differences in the morphology of these structures. The values obtained with ultrasonography and MRI, were also different from each other for both the central and lateral portions of the plantar aponeurosis, but with no statistical significance. We have described the detailed anatomy of the plantar aponeurosis with emphasis on the more distal structures that can be visualized with MRI. There was no statistically significant difference between the accuracy of ultrasonography and MRI regarding the measurements of the thickness of the central and lateral portions of the plantar aponeurosis. Knowledge of the normal anatomy of these structures enables the radiologist to identify early

  1. Reversible Causes in Cardiovascular Collapse at the Emergency Department Using Ultrasonography (REVIVE-US).

    Science.gov (United States)

    Chua, Mui Teng; Chan, Gene Wh; Kuan, Win Sen

    2017-08-01

    Ultrasonographic evaluation of patients in cardiac arrest is currently not protocolised in the advanced cardiac life support (ACLS) algorithm. Potentially reversible causes may be identified using bedside ultrasonography that is ubiquitous in most emergency departments (EDs). This study aimed to evaluate the incidence of sonographically detectable reversible causes of cardiac arrest by incorporating an ultrasonography protocol into the ACLS algorithm. Secondary objectives include rates of survival to hospital admission, hospital discharge, and 30-day mortality. We conducted a prospective study using bedside ultrasonography to evaluate for potentially reversible causes in patients with cardiac arrest at the ED of National University Hospital, Singapore, regardless of the initial electrocardiogram rhythm. A standardised ultrasonography protocol was performed during the 10-second pulse check window. Between June 2015 and April 2016, 104 patients were recruited, corresponding to 65% of all out-of-hospital cardiac arrest patients conveyed to the ED. Median age was 71 years (interquartile range, 55 to 80) and 71 (68.3%) patients were male. The most common rhythm on arrival was asystole (45.2%). Four (3.8%) patients had ultrasonographic findings suggestive of massive pulmonary embolism while 1 received intravenous thrombolysis and survived until discharge. Pericardial effusion without tamponade was detected in 4 (3.8%) patients and 6 (5.8%) patients had intra-abdominal free fluid. Twenty (19.2%) patients survived until admission, 2 of whom (1.9%) survived to discharge and beyond 30 days. Bedside ultrasonography can be safely incorporated into the ACLS protocol. Detection of any reversible causes may alter management and improve survival in selected patients.

  2. Accuracy of ultrasonography and magnetic resonance imaging in the diagnosis of placenta accreta.

    Directory of Open Access Journals (Sweden)

    Anne-Sophie Riteau

    Full Text Available PURPOSE: To evaluate the accuracy of ultrasonography and magnetic resonance imaging (MRI in the diagnosis of placenta accreta and to define the most relevant specific ultrasound and MRI features that may predict placental invasion. MATERIAL AND METHODS: This study was approved by the institutional review board of the French College of Obstetricians and Gynecologists. We retrospectively reviewed the medical records of all patients referred for suspected placenta accreta to two university hospitals from 01/2001 to 05/2012. Our study population included 42 pregnant women who had been investigated by both ultrasonography and MRI. Ultrasound images and MRI were blindly reassessed for each case by 2 raters in order to score features that predict abnormal placental invasion. RESULTS: Sensitivity in the diagnosis of placenta accreta was 100% with ultrasound and 76.9% for MRI (P = 0.03. Specificity was 37.5% with ultrasonography and 50% for MRI (P = 0.6. The features of greatest sensitivity on ultrasonography were intraplacental lacunae and loss of the normal retroplacental clear space. Increased vascularization in the uterine serosa-bladder wall interface and vascularization perpendicular to the uterine wall had the best positive predictive value (92%. At MRI, uterine bulging had the best positive predictive value (85% and its combination with the presence of dark intraplacental bands on T2-weighted images improved the predictive value to 90%. CONCLUSION: Ultrasound imaging is the mainstay of screening for placenta accreta. MRI appears to be complementary to ultrasonography, especially when there are few ultrasound signs.

  3. [The diagnostic value of ultrasonic elastography and ultrasonography comprehensive score in cervical lesions].

    Science.gov (United States)

    Lu, R; Xiao, Y

    2017-07-18

    Objective: To evaluate the clinical value of ultrasonic elastography and ultrasonography comprehensive scoring method in the diagnosis of cervical lesions. Methods: A total of 116 patients were selected from the Department of Gynecology of the first hospital affiliated with Central South University from March 2014 to September 2015.All of the lesions were preoperatively examined by Doppler Ultrasound and elastography.The elasticity score was determined by a 5-point scoring method. Calculation of the strain ratio was based on a comparison of the average strain measured in the lesion with the adjacent tissue of the same depth, size, and shape.All these ultrasonic parameters were quantified, added, and arrived at ultrasonography comprehensive scores.To use surgical pathology as the gold standard, the sensitivity, specificity, accuracy of Doppler Ultrasound, elasticity score and strain ratio methods and ultrasonography comprehensive scoring method were comparatively analyzed. Results: (1) The sensitivity, specificity, and accuracy of Doppler Ultrasound in diagnosing cervical lesions were 82.89% (63/76), 85.0% (34/40), and 83.62% (97/116), respectively.(2) The sensitivity, specificity, and accuracy of the elasticity score method were 77.63% (59/76), 82.5% (33/40), and 79.31% (92/116), respectively; the sensitivity, specificity, and accuracy of the strain ratio measure method were 84.21% (64/76), 87.5% (35/40), and 85.34% (99/116), respectively.(3) The sensitivity, specificity, and accuracy of ultrasonography comprehensive scoring method were 90.79% (69/76), 92.5% (37/40), and 91.38% (106/116), respectively. Conclusion: (1) It was obvious that ultrasonic elastography had certain diagnostic value in cervical lesions. Strain ratio measurement can be more objective than elasticity score method.(2) The combined application of ultrasonography comprehensive scoring method, ultrasonic elastography and conventional sonography was more accurate than single parameter.

  4. Cost-effectiveness analysis of ultrasonography screening for nonalcoholic fatty liver disease in metabolic syndrome patients

    Science.gov (United States)

    Phisalprapa, Pochamana; Supakankunti, Siripen; Charatcharoenwitthaya, Phunchai; Apisarnthanarak, Piyaporn; Charoensak, Aphinya; Washirasaksiri, Chaiwat; Srivanichakorn, Weerachai; Chaiyakunapruk, Nathorn

    2017-01-01

    Abstract Background: Nonalcoholic fatty liver disease (NAFLD) can be diagnosed early by noninvasive ultrasonography; however, the cost-effectiveness of ultrasonography screening with intensive weight reduction program in metabolic syndrome patients is not clear. This study aims to estimate economic and clinical outcomes of ultrasonography in Thailand. Methods: Cost-effectiveness analysis used decision tree and Markov models to estimate lifetime costs and health benefits from societal perspective, based on a cohort of 509 metabolic syndrome patients in Thailand. Data were obtained from published literatures and Thai database. Results were reported as incremental cost-effectiveness ratios (ICERs) in 2014 US dollars (USD) per quality-adjusted life year (QALY) gained with discount rate of 3%. Sensitivity analyses were performed to assess the influence of parameter uncertainty on the results. Results: The ICER of ultrasonography screening of 50-year-old metabolic syndrome patients with intensive weight reduction program was 958 USD/QALY gained when compared with no screening. The probability of being cost-effective was 67% using willingness-to-pay threshold in Thailand (4848 USD/QALY gained). Screening before 45 years was cost saving while screening at 45 to 64 years was cost-effective. Conclusions: For patients with metabolic syndromes, ultrasonography screening for NAFLD with intensive weight reduction program is a cost-effective program in Thailand. Study can be used as part of evidence-informed decision making. Translational Impacts: Findings could contribute to changes of NAFLD diagnosis practice in settings where economic evidence is used as part of decision-making process. Furthermore, study design, model structure, and input parameters could also be used for future research addressing similar questions. PMID:28445256

  5. Changes of red blood cell aggregation parameters in a long-term follow-up of splenectomy, spleen-autotransplantation and partial or subtotal spleen resections in a canine model.

    Science.gov (United States)

    Miko, Iren; Nemeth, Norbert; Peto, Katalin; Furka, Andrea; Toth, Laszlo; Furka, Istvan

    2017-01-01

    Decrease or loss in splenic filtration function may influence the hemorheological state. To follow-up the long-term effects of splenectomy, spleen autotransplantation and spleen resections on red blood cell aggregation in a canine model. Beagle dogs were subjected to control (n = 6), splenectomy (SE, n = 4), spleen autotransplantation (AU, Furka's spleen-chip method, n = 8) or partial and subtotal spleen resection (n = 4/each) groups, and followed-up for 18 postoperative (p.o.) months. Erythrocyte aggregation was determined in parallel by light-transmittance aggregometry (Myrenne MA-1 aggregometer) and syllectometry (LoRRca). Erythrocyte aggregation decreased three months after splenectomy, with lower aggregation index and elongated aggregation time. It was more or less associated with relatively lower hematocrit and fibrinogen concentration. However, in autotransplantated animals a relatively higher fibrinogen did not increase the aggregation markedly. Spleen resection resulted in the most controversial red blood cell aggregation findings, and it seems, that the degree of the resection is an influencing factor. Splenectomy alters erythrocyte aggregation, spleen autotransplantation can be useful to preserve filtration function. However, the degree of restoration shows individual differences with a kind of 'functional periodicity'. Spleen resection controversially influences erythrocyte aggregation parameters. The subtotal resection is supposed to be worse than spleen autotransplantation.

  6. Diagnostic value of ultrasonography in evaluation and management of acute abdominal conditions in the paediatric age group

    Directory of Open Access Journals (Sweden)

    Mohd Khalid

    2012-01-01

    Full Text Available Background: The aims of this study have been elaborated below: (1 to enumerate the common causes of acute abdominal emergencies by ultrasonography in paediatric patients; (2 to establish the diagnostic efficacy of ultrasonography in evaluation of acute abdominal conditions in children and to illustrate the associated ultrasonographic findings; (3 and, to discuss the role of ultrasonography in guiding the mode of intervention in these cases. Patients and Methods: This prospective study of ultrasonographic examination in 146 paediatric patients presenting with acute onset abdominal pain at the emergency/paediatric outpatient department section of Jawaharlal Nehru Medical College & Hospital, Aligarh, between June 2006 and December 2007, using 3.75 MHz and 8 MHz transducers of the ADARA (Siemens machine. Results : Common causes of acute abdominal emergencies in pediatric patients as noted on ultrasonography included nonspecific pain (28%, abdominal abscess (21%, acute appendicitis (7% and intussusception (7%. Ultrasonography was diagnostic in 45.2% cases and supportive in 12.3% of the cases. As for as the final outcome, ultrasonography prevented surgery in almost 20% cases and laparotomy was avoided in 7% of the patients as ultrasound guided interventions in the form of abscess aspiration were carried out. Conclusion: Ultrasonography evaluation of children with acute abdominal pain, helps in making significant changes in the management plan of the patients, and also reveals various clinically unsuspected diseases.

  7. Effect of adding screening ultrasonography to screening mammography on patient recall and cancer detection rates: A retrospective study in Japan

    International Nuclear Information System (INIS)

    Tohno, Eriko; Umemoto, Takeshi; Sasaki, Kyoko; Morishima, Isamu; Ueno, Ei

    2013-01-01

    Purpose: To determine whether adding screening ultrasonography to screening mammography can reduce patient recall rates and increase cancer detection rates. Materials and methods: We analyzed the results of mammography and ultrasonography breast screenings performed at the Total Health Evaluation Center Tsukuba, Japan, between April 2011 and March 2012. We also reviewed the modalities and results of diagnostic examinations from women with mammographic abnormalities who visited the Tsukuba Medical Center Hospital for further testing. Results: Of 11,753 women screened, cancer was diagnosed in 10 (0.22%) of the 4529 participants who underwent mammography alone, 23 (0.37%) of the 6250 participants who underwent ultrasonography alone, and 5 (0.51%) of the 974 participants who underwent mammography and ultrasonography. The recall rate due to mammographic abnormalities was 4.9% for women screened only with mammography and 2.6% for those screened with both modalities. The cancer detection rate was 0.22% for women screened only with mammography (positive predictive value, 4.5%) and 0.31% for those screened with both modalities (positive predictive value, 12.0%). Of the 211 lesions presenting as mammographic abnormalities investigated further, diagnostic ultrasonography found no abnormalities in 63 (29.9%) and benign findings in 69 (33.7%). The rest 36.4% needed mammography, cytological or histological examinations or follow-up in addition to diagnostic ultrasonography. Conclusions: It is possible to reduce the recall rate in screening mammography by combining mammography and ultrasonography for breast screening

  8. Use of resources and costs associated with the treatment of Dupuytren’s contracture at an orthopedics and traumatology surgery department in Denia (Spain): collagenase clostridium hystolyticum versus subtotal fasciectomy

    Science.gov (United States)

    2013-01-01

    Background Our purpose was to analyze and compare the use of direct health resources and costs generated in the treatment of Dupuytren's contracture using two different techniques: subtotal fasciectomy and infiltration with Collagenase Clostridium Histolyticum (CCH) in regular clinical practice at the Orthopedic and Traumatology Surgery (OTS) Department at the Hospital de Denia (Spain). Methods Observational, retrospective study based on data from the computerized clinical histories of two groups of patients- those treated surgically using a one or two digit subtotal fasciectomy technique (FSC) and those treated with CCH infiltration, monitored in regular clinical practice from February, 2009 to May, 2012. Demographic (age, sex), clinical (number of digits affected and which ones) and use of resources (hospitalizations, medical visits, tests and drugs) data were collected. Resource use and associated costs, according to the hospital’s accounting department, were compared based on the type of treatment from Spain’s National Health Service. Results 91 patients (48 (52.8%) in the FSC group) were identified. The average age and number of digits affected was 65.9 (9.2) years and 1.33 (0.48) digits affected in the FSC group, and 65.1 (9.7) years and 1.16 (0.4) digits in the CCH group. Overall, the costs of treating Dupuytren's disease with subtotal FSC amount to €1,814 for major ambulatory surgery and €1,961 with hospital stay including admission, surgical intervention (€904), examinations, dressings and physiotherapy. As to collagenase infiltration, costs amount to €952 (including minor surgery admission, vial with product, office examination and dressings). Finally, comparing total costs for treatments, a savings of €388 is estimated in favor of CCH treatment in the best-case scenario (patient under MAS system with no need for physiotherapy) and €1,008 in the worst-case scenario (patient admitted to hospital needing subsequent physiotherapy), implying a

  9. Transfer from point-of-care Ultrasonography training to diagnostic performance on patients--a randomized controlled trial

    DEFF Research Database (Denmark)

    Todsen, Tobias; Jensen, Morten Lind; Tolsgaard, Martin Grønnebæk

    2016-01-01

    BACKGROUND: Clinicians are increasingly using point-of-care ultrasonography for bedside examinations of patients. However, proper training is needed in this technique, and it is unknown whether the skills learned from focused Ultrasonography courses are being transferred to diagnostic performance...... test and binary logistic regression, respectively. RESULTS: There was a significant difference in the performance score between the intervention group (27.4%) and the control group (18.0%, P = .004) and the diagnostic accuracy between the intervention group (65%) and the control group (39%, P = .014......). CONCLUSIONS: Clinicians could successfully transfer learning from an Ultrasonography course to improve diagnostic performance on patients. However, our results also indicate a need for more training when new technologies such as point-of-care ultrasonography are introduced....

  10. Impact of Endoscopic Ultrasonography on (18)F-FDG-PET/CT Upfront Towards Patient Specific Esophageal Cancer Treatment

    NARCIS (Netherlands)

    Hulshoff, J. B.; Mul, V. E. M.; de Boer, H. E. M.; Noordzij, W.; Korteweg, T.; van Dullemen, H. M.; Nagengast, W. B.; Oppedijk, V.; Pierie, J. P. E. N.; Plukker, John Th. M.

    INTRODUCTION: In patients with potentially resectable esophageal cancer (EC), the value of endoscopic ultrasonography (EUS) after fluorine-18 labeled fluorodeoxyglucose positron emission tomography with computed tomography ((18)F-FDG-PET/CT) is questionable. Retrospectively, we assessed the impact

  11. Cost-effectiveness of endoscopic ultrasonography, magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography in patients suspected of pancreaticobiliary disease

    DEFF Research Database (Denmark)

    Ainsworth, A P; Rafaelsen, S R; Wamberg, P A

    2004-01-01

    BACKGROUND: It is not known whether initial endoscopic ultrasonography (EUS) or magnetic resonance cholangiopancreatography (MRCP) is more cost effective than endoscopic retrograde cholangiopancreatography (ERCP). METHODS: A cost-effectiveness analysis of EUS, MRCP and ERCP was performed on 163...

  12. Efficacy of voided urinary cytology and ultrasonography compared to cystoscopy in the detection of urinary bladder cancer

    Directory of Open Access Journals (Sweden)

    N. Kumar

    2017-09-01

    Conclusions: Voided urinary cytology can be omitted as a screening test. Ultrasonography can be recommended as the initial imaging investigation for detection of bladder carcinoma in patients presenting with hematuria and for follow up of bladder carcinoma patients.

  13. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography. Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-02-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt.

  14. International guidelines for contrast-enhanced ultrasonography: Ultrasound imaging in the new millennium

    International Nuclear Information System (INIS)

    Nolsoe, Christian Pallson; Lorentzen, Torben

    2016-01-01

    The intent of this review is to discuss and comment on common clinical scenarios in which contrast-enhanced ultrasonography (CEUS) may play a decisive role and to illustrate important points with typical cases. With the advent of CEUS, the scope of indications for ultrasonography has been dramatically extended, and now includes functional imaging and tissue characterization, which in many cases enable tumor diagnosis without a biopsy. It is virtually impossible to imagine the practice of modern medicine as we know it in high-income countries without the use of imaging, and yet, an estimated two thirds of the global population may receive no such care. Ultrasound imaging with CEUS has the potential to correct this inequity

  15. Contrast-enhanced power Doppler ultrasonography of the metacarpophalangeal joints in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, Michel; Strandberg, Charlotte

    2003-01-01

    The aim of this study was to examine, with dynamic contrast-enhanced MRI as the reference, if contrast-enhanced power Doppler ultrasonography (CE PDUS) of rheumatoid arthritis (RA) metacarpophalangeal (MCP) joints provides additional information for evaluation of synovial inflammation compared...... with PDUS. One MCP joint in each of 15 RA patients and 3 healthy control persons were examined with PDUS before and after intravenous bolus Levovist contrast injection. Corresponding rates of early synovial enhancement (RESE), previously shown to be closely related to histopathological synovitis, were...... calculated from dynamic contrast-enhanced MR images obtained the same day. Prior to ultrasonography, the joint was evaluated clinically. Levovist increased the flow signal in 7 of 9 joints with pre-contrast flow-signal and in 0 of 9 without pre-contrast signal. No healthy controls showed CE PDUS signal...

  16. International guidelines for contrast-enhanced ultrasonography: Ultrasound imaging in the new millennium

    Energy Technology Data Exchange (ETDEWEB)

    Nolsoe, Christian Pallson; Lorentzen, Torben [Ultrasound Section, Dept. of Gastric Surgery, Herlev Hospital, University of Copenhagen, Herlev (Denmark)

    2016-03-15

    The intent of this review is to discuss and comment on common clinical scenarios in which contrast-enhanced ultrasonography (CEUS) may play a decisive role and to illustrate important points with typical cases. With the advent of CEUS, the scope of indications for ultrasonography has been dramatically extended, and now includes functional imaging and tissue characterization, which in many cases enable tumor diagnosis without a biopsy. It is virtually impossible to imagine the practice of modern medicine as we know it in high-income countries without the use of imaging, and yet, an estimated two thirds of the global population may receive no such care. Ultrasound imaging with CEUS has the potential to correct this inequity.

  17. Epiploic appendicitis and omental infarction. Findings in the ultrasonography and computerized tomography

    International Nuclear Information System (INIS)

    Migule, A.; Ripolles, T.; Martinez, M. J.; Morote, V.; Ruiz, A.

    2001-01-01

    Describe the findings in the ultrasonography and computerized tomography (CT) of the omental infarction and epiploic appendicitis. The clinical and radiological findings of the patients diagnosed in our hospital with epiploic appendicitis or omental infarctions between August 1994 and March 2001 were assessed retrospectively. We found a high incidence (42 cases) of these two diseases: 30 patients with diagnosis of epiploic appendicitis and 12 with the diagnosis of omental infarction. Four patients were treated surgically, while the remaining 38 were conservatively, without posterior complications. The ultrasonography and CT images is characteristics. making it possible to make a diagnosis of epiploic appendicitis or omental infarction with certainty. It is not necessary to make a differential diagnosis between the two entities because their prognosis and treatment are similar. Their incidence is much more frequent than that previously published. (Author) 19 refs

  18. MR imaging and ultrasonography findings of early myositis ossificans: a case report

    International Nuclear Information System (INIS)

    Lee, Kyung Ryeol; Park, So Young; Jin, Wook; Won, Kyu Yeoun

    2016-01-01

    Myositis ossificans (MO) is a benign soft tissue lesion with non-neoplastic heterotopic bone formation. MO in the intermediate and mature stages can be easily diagnosed if characteristic imaging findings such as a peripheral zonal pattern of ossification with variable thickness is observed. However, it is difficult to correctly diagnose early MO because it can mimic malignancy clinically, radiologically, and histopathologically. We report a case of early pseudosarcomatous phase of non-traumatic MO with atypical imaging findings. A 59-year-old woman presented with pain followed by a mass in the left thigh within a week. MR imaging and ultrasonography showed an intramuscular lesion with preserved muscle fascicles in the vastus lateralis muscle. Intralesional ossification or calcification was not seen on ultrasonography. A diagnosis of myositis ossificans was made by ultrasonographically guided biopsy. (orig.)

  19. MR imaging and ultrasonography findings of early myositis ossificans: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ryeol [Jeju National University Hospital, Department of Radiology, Jeju-si, Jeju Special Self-Governing Province (Korea, Republic of); Park, So Young; Jin, Wook [Kyung Hee University Hospital at Gangdong, Department of Radiology, Seoul (Korea, Republic of); Won, Kyu Yeoun [Kyung Hee University Hospital at Gangdong, Department of Pathology, Seoul (Korea, Republic of)

    2016-10-15

    Myositis ossificans (MO) is a benign soft tissue lesion with non-neoplastic heterotopic bone formation. MO in the intermediate and mature stages can be easily diagnosed if characteristic imaging findings such as a peripheral zonal pattern of ossification with variable thickness is observed. However, it is difficult to correctly diagnose early MO because it can mimic malignancy clinically, radiologically, and histopathologically. We report a case of early pseudosarcomatous phase of non-traumatic MO with atypical imaging findings. A 59-year-old woman presented with pain followed by a mass in the left thigh within a week. MR imaging and ultrasonography showed an intramuscular lesion with preserved muscle fascicles in the vastus lateralis muscle. Intralesional ossification or calcification was not seen on ultrasonography. A diagnosis of myositis ossificans was made by ultrasonographically guided biopsy. (orig.)

  20. Evaluation of acute radiation optic neuropathy by B-scan ultrasonography

    International Nuclear Information System (INIS)

    Lovato, A.A.; Char, D.H.; Quivey, J.M.; Castro, J.R.

    1990-01-01

    We studied the accuracy of B-scan ultrasonography to diagnose radiation-induced optic neuropathy in 15 patients with uveal melanoma. Optic neuropathy was diagnosed by an observer masked as to clinical and photographic data. We analyzed planimetry area measurements of the retrobulbar nerve before and after irradiation. The retrobulbar area of the optic nerve shadow on B-scan was quantitated with a sonic digitizer. Increased optic nerve shadow area was confirmed in 13 of 15 patients who had radiation optic neuropathy (P less than .004). The correct diagnosis was confirmed when the results of ultrasound were compared to fundus photography and fluorescein angiography. In 13 patients there was acute radiation optic neuropathy. Two patients did not show an enlarged retrobulbar optic nerve, and the clinical appearance suggested early progression to optic atrophy. Ultrasonography documents the enlargement of the optic nerve caused by acute radiation changes

  1. The combined use of senometry and ultrasonography for breast cancer surgical planning

    Directory of Open Access Journals (Sweden)

    Ștefan Voiculescu

    2017-11-01

    Full Text Available Ultrasound exerts an important role in breast cancer diagnosis protocol, but the use of eco-senometry can also improve therapeutic options, surgical planning and technique. We describe various measurement formulas and techniques that are applied in order to acquire important information regarding the breast and its lesions. Senometry and ultrasonography have been proven to be very effective, reaching up to reliability levels as high as 0.997 and accuracy levels as high as 99.6%. Senometry and ultrasonography have clearly demonstrated their value in breast cancer diagnosis and treatment. These methods are reliable, inexpensive and can be easily performed by the surgeon. More advances in the domain are expected in the future.

  2. Prediction of late failure after medical abortion from serial beta-hCG measurements and ultrasonography

    DEFF Research Database (Denmark)

    Rørbye, C; Nørgaard, M; Nilas, Lisbeth

    2004-01-01

    on day 15 were greater among late failures than successes. Used as a predictive test, the positive predictive values of these variables were low. CONCLUSION: Neither beta-hCG nor endometrial thickness can be used clinically as diagnostic tests in predicting late failure after medical abortion.......BACKGROUND: Surgical treatment of failed medical abortion may be performed several weeks after initiation of the abortion. There are no recognized methods for early identification of these late failures. We assessed the prognostic values of beta-hCG and ultrasonography in predicting late failure...... thickness by ultrasonography was performed on day 15 after induction of medical abortion. Failures diagnosed after day 15 and within 15 weeks were identified and classified as late failures. All interventions in this group were due to bleeding problems. The predictive values of different absolute...

  3. Doppler ultrasonography of the pectinis oculi artery in harpy eagles (Harpia harpyja

    Directory of Open Access Journals (Sweden)

    Wanderlei de Moraes

    2017-03-01

    Full Text Available Twenty harpy eagles (Harpia harpyja without systemic or ocular diseases were examined to measure blood velocity parameters of the pectinis oculi artery using Doppler ultrasonography. Pectinate artery resistive index (RI and pulsatility index (PI were investigated using ocular Doppler ultrasonography. The mean RI and PI values across all eyes were 0.44±0.10 and 0.62±0.20 respectively. Low RI and PI values found in the harpy eagle´s pectinis oculi artery compared with the American pekin ducks one and other tissue suggest indeed a high metabolic activity in pecten oculi and corroborates the hypothesis of a nutritional function and/or intraocular pressure regulation.

  4. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    Energy Technology Data Exchange (ETDEWEB)

    Ayaz, Tunahan; Akansel, Gur. E-mail: gakansel@superonline.com; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-06-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia.

  5. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    International Nuclear Information System (INIS)

    Ayaz, Tunahan; Akansel, Gur.; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-01-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia

  6. Abdominal ultrasonography in the diagnostic work-up in children with recurrent abdominal pain

    DEFF Research Database (Denmark)

    Wewer, Anne Vibeke; Strandberg, C; Pærregaard, Anders

    1997-01-01

    We report on our experience with routine abdominal ultrasonography in 120 children (aged 3-15 years) with recurrent abdominal pain, in order to determine the diagnostic value of this investigation. Eight children (7%) revealed sonographic abnormalities: gallbladder stone (n = 2), splenomegaly (n...... = 1) and urogenital abnormalities (n = 5). The recurrent abdominal pain could be explained by these findings in only two (may be three) cases. CONCLUSION: The diagnostic value of abdominal ultrasonography in unselected children with recurrent abdominal pain is low. However, the direct visualization...... of the abdominal structures as being normal may be helpful to the parents and the child in their understanding and acceptance of the benign nature of recurrent abdominal pain....

  7. Congenital abdominal dumbbell fashion neuroblastoma with invasion of spinal canal detected by ultrasonography - case report

    International Nuclear Information System (INIS)

    Kosiak, W.; Czarniak, P.; Swieton, D.; Piskunowicz, M.; Drozynska, E.; Szolkiewicz, A.

    2007-01-01

    A case of congenital abdominal dumbbell fashion neuroblastoma with invasion of the spinal canal detected by ultrasonography (US) is presented. A 3-week-old male neonate was admitted to the hospital with a palpable mass in the left lumbar region. Ultrasound examination was performed on the same day. It disclosed a pathologic mass filling the left side of the retroperitoneal space - displacing laterally and inferiorly the left kidney. The second part of the tumor was located above the Gerot's fascia in the muscles and infiltrated the tomography scanning confirmed the presence of solid masses in these locations. Urinary excretion of vanillin-mandelic acid (VMA) was within normal range, ferritin level was elevated (447 μg/ml). Bone scintigraphy showed metastases to the left clavicle. There were no changes in bone marrow. Diagnosis of an undifferentiated malignant neuroblastoma was established in histopathological examination. Spinal ultrasonography is highly recommended in neonates and infants with retroperitoneal tumors. (author)

  8. Ultrasonography of adnexal causes of acute pelvic pain in pre-menopausal non-pregnant women

    Directory of Open Access Journals (Sweden)

    Carolyn S. Dupuis

    2015-10-01

    Full Text Available Acute-onset pelvic pain is an extremely common symptom in premenopausal women presenting to the emergency department. After excluding pregnancy in reproductive-age women, ultrasonography plays a major role in the prompt and accurate diagnosis of adnexal causes of acute pelvic pain, such as hemorrhagic ovarian cysts, endometriosis, ovarian torsion, and tubo-ovarian abscess. Its availability, relatively low cost, and lack of ionizing radiation make ultrasonography an ideal imaging modality in women of reproductive age. The primary goal of imaging in these patients is to distinguish between adnexal causes of acute pelvic pain that may be managed conservatively or medically, and those requiring emergency/urgent surgical or percutaneous intervention.

  9. Diagnosis of a sigmoid volvulus in pregnancy: ultrasonography and magnetic resonance imaging findings.

    Science.gov (United States)

    Palmucci, Stefano; Lanza, Maria Letizia; Gulino, Fabrizio; Scilletta, Beniamino; Ettorre, Giovanni Carlo

    2014-02-01

    Sigmoid volvulus complicating pregnancy is a rare, non-obstetric cause of abdominal pain that requires prompt surgical intervention (decompression) to avoid intestinal ischemia and perforation. We report the case of a 31-week pregnant woman with abdominal pain and subsequent development of constipation. Preoperative diagnosis was achieved using magnetic resonance imaging and ultrasonography: the large bowel distension and a typical whirl sign - near a sigmoid colon transition point - suggested the diagnosis of sigmoid volvulus. The decision to refer the patient for emergency laparotomy was adopted without any ionizing radiation exposure, and the pre-operative diagnosis was confirmed after surgery. Imaging features of sigmoid volvulus and differential diagnosis from other non-obstetric abdominal emergencies in pregnancy are discussed in our report, with special emphasis on the diagnostic capabilities of ultrasonography and magnetic resonance imaging.

  10. Survival Analysis of Occipital Nerve Stimulator Leads Placed under Fluoroscopic Guidance with and without Ultrasonography.

    Science.gov (United States)

    Jones, James H; Brown, Alison; Moyse, Daniel; Qi, Wenjing; Roy, Lance

    2017-11-01

    Electrical stimulation of the greater occipital nerves is performed to treat pain secondary to chronic daily headaches and occipital neuralgia. The use of fluoroscopy alone to guide the surgical placement of electrodes near the greater occipital nerves disregards the impact of tissue planes on lead stability and stimulation efficacy. We hypothesized that occipital neurostimulator (ONS) leads placed with ultrasonography combined with fluoroscopy would demonstrate increased survival rates and times when compared to ONS leads placed with fluoroscopy alone. A 2-arm retrospective chart review. A single academic medical center. This retrospective chart review analyzed the procedure notes and demographic data of patients who underwent the permanent implant of an ONS lead between July 2012 and August 2015. Patient data included the diagnosis (reason for implant), smoking tobacco use, disability, and age. ONS lead data included the date of permanent implant, the imaging modality used during permanent implant (fluoroscopy with or without ultrasonography), and, if applicable, the date and reason for lead removal. A total of 21 patients (53 leads) were included for the review. Chi-squared tests, Fishers exact tests, 2-sample t-tests, and Wilcoxon rank-sum tests were used to compare fluoroscopy against combined fluoroscopy and ultrasonography as implant methods with respect to patient demographics. These tests were also used to evaluate the primary aim of this study, which was to compare the survival rates and times of ONS leads placed with combined ultrasonography and fluoroscopy versus those placed with fluoroscopy alone. Survival analysis was used to assess the effect of implant method, adjusted for patient demographics (age, smoking tobacco use, and disability), on the risk of lead explant. Data from 21 patients were collected, including a total of 53 ONS leads. There was no statistically significant difference in the lead survival rate or time, disability, or patient age

  11. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-01-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt. (author)

  12. The role of ultrasonography in the management of lung and pleural diseases.

    Science.gov (United States)

    Rumende, C Martin

    2012-04-01

    Ultrasonographic examination in pulmonology provides a revolutionary advance because it is very helpful in the diagnosis and management of various pleural and peripheral pulmonary defects. Lung ultrasonography allows the clinicians to diagnose some pulmonary abnormalities more rapidly, including the diagnosis of pleural effusion. Ultrasound examination also provides great assistance for the clinicians to perform invasive techniques in the field of pulmonology, which may increase the success rate and reduce the likelihood of complications. In addition to pleural effusion, other lung disorders can be diagnosed by ultrasound such as peripheral lung tumors and other pleural abnormalities caused by pleural fibrosis and tumor metastasis as well as the primary pleural tumor (mesothelioma). Ultrasound-guided invasive procedures include aspiration of minimal effusion, Transthoracal Needle Aspiration, Transthoracal biopsies and chest tube insertion. Lung ultrasound also offers other advantages, i.e. free from radiation hazards, portable, non-invasive and relatively inexpensive. Ultrasonography in the thorax also has its limitations, especially in detecting mediastinal abnormalities.

  13. Anatomy, histology, and ultrasonography of the normal adrenal gland in brown lemur: Eulemur fulvus.

    Science.gov (United States)

    Raharison, Fidiniaina; Bourges Abella, Nathalie; Sautet, Jean; Deviers, Alexandra; Mogicato, Giovanni

    2017-04-01

    The medical care currently to brown lemurs (Eulemur fulvus) is limited by a lack of knowledge of their anatomy. The aim of this study was to describe the anatomy and histology and obtain ultrasonographic measurements of normal adrenal glands in these animals. The adrenal glands of four lemurs cadavers were used for the anatomical and histological studies, and those of 15 anesthetized lemurs were examined by ultrasonography. Anatomically, the adrenal glands of brown lemurs are comparable to those of other species. The histological findings showed that the cortex is organized into three distinct layers, whereas most domestic mammals have an additional zone. The surface area of the adrenal glands increased with body weight, and the area of the right adrenal was slightly larger than the left. We suggest using ultrasonography to aid the etiological diagnosis of behavioral abnormalities that might be due to dysfunctions of the adrenal gland. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Transrectal contrast-enhanced ultrasonography, transrectal ultrasonography and retrograde cystography for the detection of vesicourethral anastomosis leakage after radical retropubic prostatectomy: a prospective comparative evaluation.

    Science.gov (United States)

    Cantiello, Francesco; Cicione, Antonio; Autorino, Riccardo; De Nunzio, Cosimo; Tubaro, Andrea; Damiano, Rocco

    2013-01-01

    To evaluate the diagnostic accuracy of cystography (CG), transrectal ultrasonography (TRUS) and transrectal contrast-enhanced ultrasonography (CEUS) for the detection of vesicourethral extravasation (VE) after radical retropubic prostatectomy (RRP). In 80 consecutive patients who underwent RRP, the strength of the vesicourethral anastomosis (VUA) was assessed by CG, TRUS and transrectal CEUS. The investigation started with a conventional CG evaluated by an experienced uroradiologist. Following this, patients underwent TRUS which was performed by an experienced urologist who was blinded to the CG findings. The examination started with a conventional B-scan and, subsequently, a CEUS was performed by emptying and refilling the bladder with 90 ml of NaCl 0.9% + 10 ml suspension of 1:10 SonoVue and NaCl 0.9%. 26 patients (32.5%) presented urinary VE and 54 (67.5%) a watertight VUA. In 16 patients (61%) we observed a small leakage, 9 patients (35%) presented a moderate VE, and a large VE was detected in 1 patient (4%). No statistically significant difference in detection of VE was found among the three tests (p = 0.472). TRUS and CEUS are able to provide information about the integrity of the VUA that is comparable with that of CG. Copyright © 2013 S. Karger AG, Basel.

  15. Two-dimensional ultrasonography of the brain: its diagnostic usefullness in herpes simplex encephalitis and cytomegalic inclusion disease.

    Science.gov (United States)

    Matsumoto, N; Yano, S; Miyao, M; Kamoshita, S; Itoh, K

    1983-01-01

    We have used brain ultrasonography in diagnosing and following up two infants, one with herpes simplex encephalitis and the other with cytomegalic inclusion disease. It was found that this technique was very useful to observe the changes of the brain parenchyma such as cystic degeneration and periventricular calcification. Also because it is non-invasive and an easy procedure, ultrasonography can be applied even for infants in critical condition when needed.

  16. Value of Lung Ultrasonography in the Diagnosis and Outcome Prediction of Pediatric Community-Acquired Pneumonia with Necrotizing Change.

    Directory of Open Access Journals (Sweden)

    Shen-Hao Lai

    Full Text Available Lung ultrasonography has been advocated in diagnosing pediatric community-acquired pneumonia. However, its function in identifying necrotizing pneumonia, a complication, has not been explored. This study investigated the value of lung ultrasonography in diagnosing pediatric necrotizing pneumonia and its role in predicting clinical outcomes.We retrospectively reviewed 236 children with community-acquired pneumonia who were evaluated using lung ultrasonography within 2-3 days after admission. The ultrasonographic features assessed included lung perfusion, the presence of hypoechoic lesions, and the amount of pleural effusion. Chest computed tomography was also performed in 96 patients as clinically indicated. Detailed records of clinical information were obtained.Our results showed a high correlation between the degree of impaired perfusion in ultrasonography and the severity of necrosis in computed tomography (r = 0.704. The degree of impaired perfusion can favorably be used to predict massive necrosis in computed tomography (area under the receiver operating characteristic curve, 0.908. The characteristics of impaired perfusion and hypoechoic lesions in ultrasonography were associated with an increased risk of pneumatocele formation (odds ratio (OR, 10.11; 95% CI, 2.95-34.64 and the subsequent requirement for surgical lung resection (OR, 8.28; 95% CI, 1.86-36.93. Furthermore, a longer hospital stay would be expected if moderate-to-massive pleural effusion was observed in addition to impaired perfusion in ultrasonography (OR, 3.08; 95% CI, 1.15-8.29.Lung ultrasonography is favorably correlated with chest computed tomography in the diagnosis of necrotizing pneumonia, especially regarding massive necrosis of the lung. Because it is a simple and reliable imaging tool that is valuable in predicting clinical outcomes, we suggest that ultrasonography be applied as a surrogate for computed tomography for the early detection of severe necrotizing

  17. Endoscopic Ultrasonography in the Diagnosis and Treatment Strategy Choice of Esophageal Leiomyoma.

    Science.gov (United States)

    Sun, Ling-Jia; Chen, Xin; Dai, Yi-Ning; Xu, Cheng-Fu; Ji, Feng; Chen, Li-Hua; Chen, Hong-Tan; Chen, Chun-Xiao

    2017-04-01

    Esophageal leiomyoma is the most common benign tumor of the esophagus, and it originates from mesenchymal tissue. This study analyzed the clinicopathological characteristics of esophageal leiomyoma and aimed to evaluate the role of endoscopic ultrasonography in the diagnosis and treatment selection for these lesions. Two hundred and twenty-five patients who had suspected esophageal leiomyomas in endoscopic ultrasonography were enrolled at the Endoscopy Center of The First Affiliated Hospital, Zhejiang University from January 1st, 2009 to May 31th, 2015. The main outcomes included the demographic and morphological characteristics, symptoms, comparisons of diagnosis and treatment methods, adverse events, and prognosis. One hundred and sixty-seven patients were diagnosed as having an esophageal leiomyoma by pathological examination. The mean patient age was 50.57±9.983 years. In total, 62.9% of the lesions originated from the muscularis mucosa, and the others originated from the muscularis propria. The median distance to the incisors was 30±12 cm. The median diameter was 0.72±0.99 cm. As determined by endoscopic ultrasonography, most existing leiomyomas were homogeneous, endophytic, and spherical. The leiomyomas from the muscularis mucosa were smaller than those from the muscularis propria and much closer to the incisors (pleiomyomas presented less adverse events and better recovery (pleiomyomas. Endoscopic ultrasonography has demonstrated high accuracy in the diagnosis of esophageal leiomyomas and provides great support in selecting treatments; however, EUS cannot completely avoid misdiagnosis, so combining it with other examinations may be a good strategy to solve this problem.

  18. Comparison between doppler ultrasonography and renal scintigraphy in assessment of post-transplant renal function

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yeo Chang; Shin, Byung Seok; Ohm, Joon Young; Kim, Seong Min; Ahn, Moon Sang; Yang, Shin Seok [Chungnam National University Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dept. of Radiology, Dankook University Hospital, Cheonan (Korea, Republic of)

    2016-05-15

    To compare the usefulness of Doppler ultrasonography and renal scintigraphy in the assessment of short- and long-term function of transplanted kidneys. We retrospectively reviewed the cases of 79 patients who underwent Doppler ultrasonography and technetium-99m diethylene triamine pentaacetic acid renal scintigraphy on the same day, within 4 days of renal transplantation. Image parameters were evaluated for statistical differences. There was a strong positive correlation between the glomerular filtration rate (GFR) as measured by renal scintigraphy and the estimated GFR (eGFR) based on serum creatinine levels (correlation coefficient = 0.71). Scan grade according to the time-activity curve, resistive index, and end diastolic velocity showed moderate correlations with the eGFR (correlation coefficients = -0.557, -0.329, and 0.370, respectively) in the early post-transplantation period. The mean survival time was longer in patients with lower resistive indices (≤ 0.68, 54.9 months vs. > 0.68, 29.5 months) and lower pulsatility indices (≤ 1.32, 53.8 months vs. > 1.32, 28.7 months); however, there were no statistically significant differences in the long-term follow-up period (p = 0.121 for resistive index and p = 0.074 for pulsatility index). Renal scintigraphy is a more sensitive method than Doppler ultrasonography for assessing transplanted kidney function in the early post-transplantation period. Doppler ultrasonography might reflect the long-term survival time. However, it is difficult to predict long-term renal function using either method.

  19. Ultrasonography-guided drainage of tuberculous abscess in the retromammary region : a case report

    International Nuclear Information System (INIS)

    Park, Jeong Mi; Choi, Seong Hoon; Yoon, Hyun Ki; Sung, Kyu Bo; Sohn, Byung Ho; Ahn, Sei Hyun; Gong, Gyung Yub

    1999-01-01

    We report our recent experience of successful ultrasonography-guided catheter drainage of a huge retromammary abscess in a 27-year-old female patient with pulmonary tuberculosis. For breast abscesses, the procedure can be used instead of surgery. Its merits are that it is easy and cost-effective, there is less scar formation, outpatient management may be possible, and in reported cases there has been no recurrence

  20. Comparison between magnetic resonance findings and conventional techniques (ultrasonography and mammography) in breast disease

    International Nuclear Information System (INIS)

    Martin, J.L.; Garofono, J.M.; Berquet, A.; Fernandez, F.J.; Fuentes, P.; Alvarez de Cienfuegos, E.

    1996-01-01

    Although mammography is indisputably the best diagnostic method for detecting breast abnormalities, there are other techniques, such as ultrasonography and magnetic resonance, which are increasingly widely employed as additional indispensable aids. The present work compares mammography, ultrasound and magnetic resonance images of normal breast and of the major pathologies that can be observed in breast, including sclerosing adenosis, giant fibroadenoma, multifocal carcinoma, fibrocystic breast disease, infiltrating duct carcinoma, colloid carcinoma, radical scar, abscess and breast prosthesis. (Author) 10 refs

  1. Ultrasonography-guided drainage of tuberculous abscess in the retromammary region : a case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Mi; Choi, Seong Hoon; Yoon, Hyun Ki; Sung, Kyu Bo; Sohn, Byung Ho; Ahn, Sei Hyun; Gong, Gyung Yub [Ulsan Asan Medical Center, Ulsan (Korea, Republic of)

    1999-05-01

    We report our recent experience of successful ultrasonography-guided catheter drainage of a huge retromammary abscess in a 27-year-old female patient with pulmonary tuberculosis. For breast abscesses, the procedure can be used instead of surgery. Its merits are that it is easy and cost-effective, there is less scar formation, outpatient management may be possible, and in reported cases there has been no recurrence.

  2. Clinical value of endoluminal ultrasonography in the diagnosis of rectovaginal fistula

    International Nuclear Information System (INIS)

    Yin, Hao-Qiang; Wang, Chen; Peng, Xin; Xu, Fang; Ren, Ya-Juan; Chao, Yong-Qing; Lu, Jin-Gen; Wang, Song; Xiao, Hu-Sheng

    2016-01-01

    Rectovaginal fistula (RVF) refers to a pathological passage between the rectum and vagina, which is a public health challenge. This study was aimed to explore the clinical value of endoluminal biplane ultrasonography in the diagnosis of rectovaginal fistula (RVF). Thirty inpatients and outpatients with suspected RVF from January 2006 to June 2013 were included in the study, among whom 28 underwent surgical repair. All 28 patients underwent preoperative endoluminal ultrasonography, and the obtained diagnostic results were compared with the corresponding surgical results. All of the internal openings located at the anal canal and rectum of the 28 patients and confirmed during surgery were revealed by preoperative endosonography, which showed a positive predictive value of 100 %. Regarding the 30 internal openings located in the vagina during surgery, the positive predictive value of preoperative endosonography was 93 %. The six cases of simple fistulas confirmed during surgery were revealed by endosonography; for the 22 cases of complex fistula confirmed during surgery, the positive predictive value of endosonography was 90 %. Surgery confirmed 14 cases of anal fistula and 14 cases of RVF, whereas preoperative endoluminal ultrasonography suggested 16 cases of anal fistula and 12 cases of RVF, resulting in positive predictive values of 92.3 and 93 %, respectively. The use of endoluminal biplane ultrasonography in the diagnosis of RVF can accurately determine the internal openings in the rectum or vagina and can relatively accurately identify concomitant branches and abscesses located in the rectovaginal septum. Thus, it is a good imaging tool for examining internal and external anal sphincter injuries and provides useful information for preoperative preparation and postoperative evaluation

  3. Reproducibility of duplex ultrasonography and air plethysmography used for the evaluation of chronic venous insufficiency.

    Science.gov (United States)

    Asbeutah, Akram Mahmoud; Riha, Andrea Zdena; Cameron, James Donald; McGrath, Barry Patrick

    2005-04-01

    The purpose of this study was to determine the reproducibility of measurements on duplex ultrasonography (DU) and air plethysmography (APG) in subjects with post-thrombotic syndrome. Duplex ultrasonography and APG were used to measure indices of lower limb venous reflux in 15 limbs with a history of deep vein thrombosis and evidence of venous insufficiency as diagnosed by ultrasonography. Three limbs were in class 0; 4 were in classes 1 to 3; and 8 were in classes 4 to 6, according to clinical, etiologic, anatomic, and pathophysiologic clinical classification. Duplex ultrasonography was performed 3 times on the same day, and venous diameter, area, peak reflux velocity, reflux flow volume, and reflux duration measurements were obtained. Air plethysmography was performed on 2 days, 7 to 10 days apart, with 1 measurement on the first day and 2 measurements on the second day. Values obtained from APG included outflow fraction, venous filling index, ejection fraction, and residual volume fraction. The measurements were performed by a vascular technologist blinded to the previous test results. One-way analysis of variance, the Student paired t test, and Bland-Altman plots were used to examine the statistical differences of the DU and APG parameters for all measurements. The mean coefficient of variation for within-subject measurements of all DU and APG parameters measured was less than 10%. Bland-Altman plots showed that there were no apparent trends with increasing values over a wide range for any of the DU parameters, nor were there any for the APG parameters. Under ideal conditions, when measured by a highly trained technologist, both DU and APG showed satisfactory reproducibility.

  4. Comparison of ultrasonography with radiography for the detection of cervical esophageal foreign body

    Directory of Open Access Journals (Sweden)

    Reza Pourrashidi

    2013-07-01

    Full Text Available Background: Detection of retained foreign bodies remains a significant problem in the emergency department. Foreign bodies can go undetected causing infectious complications ultrasonography is too inaccessible and expensive. The purpose of this study is comparison of ultrasonography with radiography for the detection of cervical esophageal foreign bodiesMethods: This cross-sectional study evaluated 58 patients referred with suspected upper esophageal foreign body in the Emergency Department, Amir Alam. Patients were evaluated with ultrasonography and x-ray. After surgical exploration, different type of foreign bodies were recorded. The SPSS statistical software was used for analysis. For applicable efficacy outcome measures, a Spearman correlation was used. Differences were significant when P<0.05. All values were expressed as the frequency and present.Results: Fifty eight patients were studied. 25 patients (43.4% were male and 31 patients (56.9% were female, in 28 (48.2% patients foreign bodies were detected in radiography. 30 patients (51.8% were not recorded in techniqe. It was found in patients 22 (78.6% organic body, and six cases (21.4% non-organic body. radiographic outcomes in patients with foreign bodies were positive in 26 patients (92.9% and in two patients (7.1% were negative. Ultrasound results were positive in 27 patients (96.4% and in one patient (3.6% were negative. Association of ultrasound and radiography results were significant in patients with foreign body (Spearman correlation=0.896, P=0.001 Kappa=0.890.Conclusion: These reports suggest that result of ultrasound with radiography for the detection foreign bodies in cervical esophagus have good agreement. The use of ultrasonography in the emergency department to detect and eventually remove foreign bodies by emergency physicians is an important issue because there is not always an ultrasound technologist or radiologist available.

  5. [Evaluation of the learning curve of residents in localizing a phantom target with ultrasonography].

    Science.gov (United States)

    Dessieux, T; Estebe, J-P; Bloc, S; Mercadal, L; Ecoffey, C

    2008-10-01

    Few information are available regarding the learning curve in ultrasonography and even less for ultrasound-guided regional anesthesia. This study aimed to evaluate in a training program the learning curve on a phantom of 12 residents novice in ultrasonography. Twelve trainees inexperienced in ultrasonography were given introductory training consisting of didactic formation on the various components of the portable ultrasound machine (i.e. on/off button, gain, depth, resolution, and image storage). Then, students performed three trials, in two sets of increased difficulty, at executing these predefined tasks: adjustments of the machine, then localization of a small plastic piece introduced into roasting pork (3 cm below the surface). At the end of the evaluation, the residents were asked to insert a 22 G needle into an exact predetermined target (i.e. point of fascia intersection). The progression of the needle was continuously controlled by ultrasound visualization using injection of a small volume of water (needle perpendicular to the longitudinal plane of the ultrasound beam). Two groups of two different examiners evaluated for each three trials the skill of the residents (quality, time to perform the machine adjustments, to localize the plastic target, and to hydrolocalize, and volume used for hydrolocalization). After each trial, residents evaluated their performance using a difficulty scale (0: easy to 10: difficult). All residents performed the adjustments from the last trial of each set, with a learning curve observed in terms of duration. Localization of the plastic piece was achieved by all residents at the 6th trial, with a shorter duration of localization. Hydrolocalization was achieved after the 4th trial by all subjects. Difficulty scale was correlated to the number of trials. All these results were independent of the experience of residents in regional anesthesia. Four trials were necessary to adjust correctly the machine, to localize a target, and to

  6. Comparison of ultrasonography and computed tomography in the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Cura, J. L. del; Oleaga, L.; Grande, D.; Farina, M. A.; Isusi, M.

    2001-01-01

    The compare the efficacy of ultrasonography and computed tomography (CT) in cases of suspected appendicitis. To study to what extent age, sex and habits of the patients, as well as the clinical context, influence the diagnostic yield of these two technique. Over a one-year period, 152 patients underwent ultrasonography and CT because of the clinical suspicion of appendicitis. The studies were carried out independently, and the results of each in terms of the presence or absence of appendicitis were unknown to the specialists performing the other. The final diagnoses were established by surgical treatment or clinical follow-up. The sensitivity of CT for the diagnosis of appendicitis was 82%, the specificity was 95%, the positive predictive value was 93%, the negative predictive value was 87% and the reliability was 90%. Ultrasonography has a sensitivity of 83%, a specificity of 97%, a positive predictive value of 95%, a negative predictive value of 88% and a reliability of 91%. Ultrasound was more efficient in patients in which there was a high clinical suspicion and in children, while the results with CT were better in patients in which the clinical diagnosis was less clear. The incidence of false negatives and positives was higher with ultrasound, while CT was more frequently able to identify a normal appendix. Sex and habits had no influence on the respective efficacies, although the performance of ultrasound was simplified in thin patients and that of CT in obese individuals. Ultrasonography and CT are highly reliable in cases of suspected appendicitis, especially when this diagnosis is conformed. Ultrasound is recommended as the technique of choice in children and in patients in which the clinical suspicion is strong. The yield of CT is somewhat greater when the clinical signs and symptoms are less clear. However, the efficacy of both techniques ultimately depends on the expertise of the specialist who interprets them. (Author) 62 refs

  7. Focused bedside ultrasonography by clinicians: experiences with a basic introductory course

    DEFF Research Database (Denmark)

    Hillingso, J.G.; Nielsen, M.B.; Svendsen, Lars Bo

    2008-01-01

    OBJECTIVE: Ultrasonography (US) performed by clinicians might shorten workout time and diminish the workload of simple diagnostic procedures for physicians specialized in US. The purpose of this follow-up study was to evaluate the effect of an introductory course in US on participants' clinical...... to be introduced for gastroenterologists and surgeons or the European Federation of Societies for Ultrasound in Medicine and Biology Guidelines should be implemented Udgivelsesdato: 2008...

  8. Can contrast-enhanced ultrasonography improve Zone III REBOA placement for prehospital care?

    Science.gov (United States)

    Chaudery, Muzzafer; Clark, James; Morrison, Jonathan J; Wilson, Mark H; Bew, Duncan; Darzi, Ara

    2016-01-01

    Torso hemorrhage is the primary cause of potentially preventable mortality in trauma. Resuscitative endovascular balloon occlusion of the aorta (REBOA) has been advocated as an adjunct to bridge patients to definitive hemorrhage control. The primary aim of this study was to assess whether contrast-enhanced ultrasonography can improve the accuracy of REBOA placement in the infrarenal aorta (Zone III). A fluoroscopy-free "enhanced" Zone III REBOA technique was developed using a porcine cadaver model. A "standard" over-the-wire Seldinger technique was used, which was enhanced with the addition of a microbubble contrast medium to inflate the balloon, observed with ultrasonography. Following this, attending- and resident-level physicians were randomized into two groups. They were taught either the enhanced with ultrasonography guidance (Group A) or the standard measuring length of catheter insertion (Group B) technique as part of a human cadaver trauma skills course. Outcomes assessed included time (seconds) from insertion to inflation, accuracy, and missed targets. All results were benchmarked against three endovascular experts. There were 20 participants who performed REBOA with Group A (51 [31]) being significantly faster than Group B (90 [63]) (p = 0.003) and more accurate (p = 0.023) with no missed targets. Group B had five missed targets, the most common error being inflation within Zone II. For Zone III REBOA, contrast-enhanced ultrasonography technique is faster and more accurate than the standard technique. This may have value in time-critical and austere environments. Clinical studies are now required to evaluate this approach further.

  9. Evaluation of prenatal hydronephrosis: novel criteria for predicting vesicoureteral reflux on ultrasonography.

    Science.gov (United States)

    Lee, Nora G; Rushton, H Gil; Peters, Craig A; Groves, Danja S; Pohl, Hans G

    2014-09-01

    Radiographic evaluation for prenatal hydronephrosis often includes voiding cystourethrography to ascertain whether vesicoureteral reflux is present. We sought to determine whether use of voiding cystourethrography could be limited to those patients at greatest risk for vesicoureteral reflux. We hypothesized that vesicoureteral reflux could be predicted by findings on renal/bladder ultrasonography of hydroureter, renal dysmorphia and/or duplication. We reviewed the records of patients with prenatal hydronephrosis who underwent initial postnatal ultrasonography and voiding cystourethrography during a 3-year period. The presence of vesicoureteral reflux on voiding cystourethrogram was correlated to ultrasound findings, including hydronephrosis grade, presence of hydroureter, renal dysmorphia or duplication, with ultrasound considered positive for any of the latter 3 findings. Of 262 patients 47 (18%) had vesicoureteral reflux. Ultrasound was positive in 24 of 29 patients (83%) with high grade reflux and 12 of 18 (67%) with low grade reflux. If ultrasonography showed any of the 3 positive findings, the odds ratio of detecting vesicoureteral reflux was 8.07 (95% CI 3.86, 16.87). Using these criteria, among all cases of prenatal hydronephrosis 5 (2%) with high grade vesicoureteral reflux and 6 (2%) with low grade reflux would have been missed. Among the 47 cases of reflux overall 5 of 29 high grade (17%) and 6 of 18 low grade cases (33%) would have been missed. By using ultrasonography criteria of hydroureter, duplication and renal dysmorphia for patients with prenatal hydronephrosis, vesicoureteral reflux can be detected more specifically. Using our criteria, 165 of 262 voiding cystourethrograms (63%) could have been avoided in patients with prenatal hydronephrosis during a 3-year period. Reducing these evaluations may decrease risks regarding radiation exposure, family anxiety and health care costs. Copyright © 2014 American Urological Association Education and

  10. Intra-abdominal fat measurement by ultrasonography: association with anthropometry and metabolic syndrome in adolescents.

    Science.gov (United States)

    Novais, Rommel L R; Café, Ana Carolina C; Morais, Aisha A; Bila, Wendell C; Santos, Gilson D da S; Lopes, Carlos Alexandre de O; Belo, Vinícius S; Romano, Márcia Christina C; Lamounier, Joel A

    2018-04-27

    To associate intra-abdominal fat thickness measured by ultrasonography to the factors related to metabolic syndrome and to determine cutoff points of intra-abdominal fat measurement associated with a greater chance of metabolic syndrome in adolescents. This was a cross-sectional study, with 423 adolescents from public schools. Intra-abdominal fat was measured by ultrasonography. Anthropometric data were collected, and biochemical analyses were performed. Intra-abdominal fat was measured by ultrasonography, showing a statistically significant association with the diagnosis of metabolic syndrome (p=0.037), body mass index (p<0.001), elevated triglyceride levels (p=0.012), decreased plasma HDL levels (p=0.034), and increased systemic blood pressure values (p=0.023). Cutoff values of intra-abdominal fat thickness measurements were calculated by ultrasound to estimate the individuals most likely to develop metabolic syndrome. In the logistic regression models, the cutoff values that showed the highest association with metabolic syndrome in males were 4.50, 5.35, 5.46, 6.24, and 6.50cm for the ages of 14, 15, 16, 17, and 18/19 years, respectively. In the female gender, the cutoff values defined for the same age groups were 4.46, 4.55, 4.45, 4.90, and 6.46cm. In an overall analysis using the ROC curve, without gender and age stratification, the cut-off of 3.67cm showed good sensitivity, but low specificity. Ultrasonography is a useful method to estimate intra-abdominal adipose tissue in adolescents, which is associated with the main factors related to obesity and metabolic syndrome. Copyright © 2018 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  11. Diagnostic imaging of the equine fetlock region using radiography and ultrasonography. Part 2: the bony disorders.

    Science.gov (United States)

    Vanderperren, Katrien; Saunders, Jimmy H

    2009-08-01

    The metacarpophangeal/metatarsophalangeal (fetlock) joint in the horse is commonly associated with equine lameness and diagnostic imaging is routinely used to investigate disorders of the joint and its surrounding tissues. This review describes the osseous disorders of the fetlock as well as the technical aspects of taking radiographic and ultrasonographic images of the different lesions. In current clinical practice, a combination of radiography and ultrasonography is still the most frequently used approach to arrive at a diagnosis.

  12. The predictive diagnostic value of serial daily bedside ultrasonography for severe dengue in Indonesian adults.

    Directory of Open Access Journals (Sweden)

    Meta Michels

    Full Text Available BACKGROUND: Identification of dengue patients at risk for progressing to severe disease is difficult. Significant plasma leakage is a hallmark of severe dengue infection which can suddenly lead to hypovolemic shock around the time of defervescence. We hypothesized that the detection of subclinical plasma leakage may identify those at risk for severe dengue. The aim of the study was to determine the predictive diagnostic value of serial ultrasonography for severe dengue. METHODOLOGY/PRINCIPAL FINDINGS: Daily bedside ultrasounds were performed with a handheld ultrasound device in a prospective cohort of adult Indonesians with dengue. Timing, localization and relation to dengue severity of the ultrasonography findings were determined, as well as the relation with serial hematocrit and albumin values. The severity of dengue was retrospectively determined by WHO 2009 criteria. A total of 66 patients with proven dengue infection were included in the study of whom 11 developed severe dengue. Presence of subclinical plasma leakage at enrollment had a positive predictive value of 35% and a negative predictive value of 90% for severe dengue. At enrollment, 55% of severe dengue cases already had subclinical plasma leakage, which increased to 91% during the subsequent days. Gallbladder wall edema was more pronounced in severe than in non-severe dengue patients and often preceded ascites/pleural effusion. Serial hematocrit and albumin measurements failed to identify plasma leakage and patients at risk for severe dengue. CONCLUSIONS/SIGNIFICANCE: Serial ultrasonography, in contrast to existing markers such as hematocrit, may better identify patients at risk for development of severe dengue. Patients with evidence of subclinical plasma leakage and/or an edematous gallbladder wall by ultrasonography merit intensive monitoring for development of complications.

  13. Comparison of radiography and ultrasonography for diagnosing small-intestinal mechanical obstruction in vomiting dogs.

    Science.gov (United States)

    Sharma, Ajay; Thompson, Margret S; Scrivani, Peter V; Dykes, Nathan L; Yeager, Amy E; Freer, Sean R; Erb, Hollis N

    2011-01-01

    A cross-sectional study was performed on acutely vomiting dogs to compare the accuracy of radiography and ultrasonography for the diagnosis of small-intestinal mechanical obstruction and to describe several radiographic and ultrasonographic signs to identify their contribution to the final diagnosis. The sample population consisted of 82 adult dogs and small-intestinal obstruction by foreign body was confirmed in 27/82 (33%) dogs by surgery or necropsy. Radiography produced a definitive result (obstructed or not obstructed) in 58/82 (70%) of dogs; ultrasonography produced a definitive result in 80/82 (97%) of dogs. On radiographs, a diagnosis of obstruction was based on detection of segmental small-intestinal dilatation, plication, or detection of a foreign body. Approximately 30% (8/27) of obstructed dogs did not have radiographic signs of segmental small-intestinal dilatation, of which 50% (4/8) were due to linear foreign bodies. The ultrasonographic diagnosis of small-intestinal obstruction was based on detection of an obstructive lesion, sonographic signs of plication or segmental, small-intestinal dilatation. The ultrasonographic presence or absence of moderate-to-severe intestinal diameter enlargement (due to lumen dilatation) of the jejunum (>1.5 cm) was a useful discriminatory finding and, when present, should prompt a thorough search for a cause of small-intestinal obstruction. In conclusion, both abdominal radiography and abdominal ultrasonography are accurate for diagnosing small-intestinal obstruction in vomiting dogs and either may be used depending on availability and examiner choice. Abdominal ultrasonography had greater accuracy, fewer equivocal results and provided greater diagnostic confidence compared with radiography. © 2010 Veterinary Radiology & Ultrasound.

  14. A practical guideline for examining a uterine niche using ultrasonography in non-pregnant women

    DEFF Research Database (Denmark)

    Jordans, I P M; de Leeuw, R; Stegwee, S I

    2018-01-01

    OBJECTIVES: To generate a uniform, internationally recognized guideline for detailed uterine niche evaluation by ultrasonography in non-pregnant women using a modified Delphi method amongst international experts. METHODS: Fifteen international gynecological experts were recruited...... definitions, relevance, method of measurement and tips for visualization of the niche. All experts agreed on the proposed guideline for niche evaluation in non-pregnant women as presented in this paper. CONCLUSION: Consensus between niche experts was achieved on all items regarding ultrasonographic niche...

  15. Diagnostic accuracy of oblique chest radiograph for occult pneumothorax: comparison with ultrasonography

    OpenAIRE

    Matsumoto, Shokei; Sekine, Kazuhiko; Funabiki, Tomohiro; Orita, Tomohiko; Shimizu, Masayuki; Hayashida, Kei; Kazamaki, Taku; Suzuki, Tatsuya; Kishikawa, Masanobu; Yamazaki, Motoyasu; Kitano, Mitsuhide

    2016-01-01

    Backgraound An occult pneumothorax is a pneumothorax that is not seen on a supine chest X-ray but is detected by computed tomography scanning. However, critical patients are difficult to transport to the computed tomography suite. We previously reported a method to detect occult pneumothorax using oblique chest radiography (OXR). Several authors have also reported that ultrasonography is an effective technique for detecting occult pneumothorax. The aim of this study was to evaluate the useful...

  16. Duplex Ultrasonography Has Limited Utility in Detection of Postoperative DVT After Primary Total Joint Arthroplasty.

    Science.gov (United States)

    Vira, Shaleen; Ramme, Austin J; Alaia, Michael J; Steiger, David; Vigdorchik, Jonathan M; Jaffe, Frederick

    2016-07-01

    Duplex ultrasound is routinely used to evaluate suspected deep venous thrombosis after total joint arthroplasty. When there is a clinical suspicion for a pulmonary embolism, a chest angiogram (chest CTA) is concomitantly obtained. Two questions were addressed: First, for the population of patients who receive duplex ultrasound after total joint arthroplasty, what is the rate of positive results? Second, for these patients, how many of these also undergo chest CTA for clinical suspicion of pulmonary embolus and how many of these tests are positive? Furthermore, what is the correlation between duplex ultrasound results and chest CTA results? A retrospective chart review was conducted of total joint replacement patients in 2011 at a single institution. Inclusion criteria were adult patients who underwent a postoperative duplex ultrasonography for clinical suspicion of deep venous thrombosis (DVT). Demographic data, result of duplex scan, clinical indications for obtaining the duplex scan, and DVT prophylaxis used were recorded. Additionally, if a chest CTA was obtained for clinical suspicion for pulmonary embolus, results and clinical indication for obtaining the test were recorded. The rate of positive results for duplex ultrasonography and chest CTA was computed and correlated based on clinical indications. Two hundred ninety-five patients underwent duplex ultrasonography of which only 0.7% were positive for a DVT. One hundred three patients underwent a chest CTA for clinical suspicion of a pulmonary embolism (PE) of which 26 revealed a pulmonary embolus, none of which had a positive duplex ultrasound. Postoperative duplex scans have a low rate of positive results. A substantial number of patients with negative duplex results subsequently underwent chest CTA for clinical suspicion for which a pulmonary embolus was found, presumably resulting from a DVT despite negative duplex ultrasound result. A negative duplex ultrasonography should not rule out the presence of a

  17. Correlation of findings in clinical and high resolution ultrasonography examinations of the painful shoulder

    Directory of Open Access Journals (Sweden)

    Raphael Micheroli

    2015-03-01

    Full Text Available Objective: High resolution ultrasonography is a non-painful and non-invasive imaging technique which is useful for the assessment of shoulder pain causes, as clinical examination often does not allow an exact diagnosis. The aim of this study was to compare the fi ndings of clinical examination and high resolution ultrasonography in patients presenting with painful shoulder. Methods: Non-interventional observational study of 100 adult patients suffering from unilateral shoulder pain. Exclusion criteria were shoulder fractures, prior shoulder joint surgery and shoulder injections in the past month. The physicians performing the most common clinical shoulder examinations were blinded to the results of the high resolution ultrasonography and vice versa. Results: In order to detect pathology of the m. supraspinatus tendon, the Hawkins and Kennedy impingement test showed the highest sensitivity (0.86 whereas the Jobe supraspinatus test showed the highest specifi city (0.55. To identify m. subscapularis tendon pathology the Gerber lift off test showed a sensitivity of 1, whereas the belly press test showed the higher specifi city (0.72. The infraspinatus test showed a high sensitivity (0.90 and specifi city (0.74. All AC tests (painful arc IIa, AC joint tendernessb, cross body adduction stress testc showed high specifi cities (a0.96, b0.99, c 0.96. Evaluating the long biceps tendon, the palm up test showed the highest sensitivity (0.47 and the Yergason test the highest specifi city (0.88. Conclusion: Knowledge of sensitivity and specifi city of various clinical tests is important for the interpretation of clinical examination test results. High resolution ultrasonography is needed in most cases to establish a clear diagnosis.

  18. Success Rate and Complications of Internal Jugular Vein Catheterization With and Without Ultrasonography Guide

    OpenAIRE

    Karimi-Sari, Hamidreza; Faraji, Mehrdad; Mohazzab Torabi, Saman; Asjodi, Gholamreza

    2014-01-01

    Background: Central venous catheterization (CVC) is an important procedure in emergency departments (EDs). Despite existence of ultrasonography (US) devices in every ED, CVC is done using anatomical landmarks in many EDs in Iran. Objectives: This study aimed to compare the traditional landmark method vs. US-guided method of CVC placement in terms of complications and success rate. Patients and Methods: In this randomized controlled trial, patients who were candidate for internal jugular vein ...

  19. Endoscopic Ultrasonography in the Diagnosis and Treatment Strategy Choice of Esophageal Leiomyoma

    Directory of Open Access Journals (Sweden)

    Ling-Jia Sun

    Full Text Available OBJECTIVES: Esophageal leiomyoma is the most common benign tumor of the esophagus, and it originates from mesenchymal tissue. This study analyzed the clinicopathological characteristics of esophageal leiomyoma and aimed to evaluate the role of endoscopic ultrasonography in the diagnosis and treatment selection for these lesions. METHODS: Two hundred and twenty-five patients who had suspected esophageal leiomyomas in endoscopic ultrasonography were enrolled at the Endoscopy Center of The First Affiliated Hospital, Zhejiang University from January 1st, 2009 to May 31th, 2015. The main outcomes included the demographic and morphological characteristics, symptoms, comparisons of diagnosis and treatment methods, adverse events, and prognosis. RESULTS: One hundred and sixty-seven patients were diagnosed as having an esophageal leiomyoma by pathological examination. The mean patient age was 50.57±9.983 years. In total, 62.9% of the lesions originated from the muscularis mucosa, and the others originated from the muscularis propria. The median distance to the incisors was 30±12 cm. The median diameter was 0.72±0.99 cm. As determined by endoscopic ultrasonography, most existing leiomyomas were homogeneous, endophytic, and spherical. The leiomyomas from the muscularis mucosa were smaller than those from the muscularis propria and much closer to the incisors (p<0.05. SMA (smooth muscle antibody (97.2% and desmin (94.5% were positive in the majority of patients. In terms of treatments, patients preferred endoscopic therapies, which led to less adverse events (e.g., intraoperative bleeding, local infection, pleural effusion than surgical operations (p<0.05. The superficial leiomyomas presented less adverse events and better recovery (p<0.05 than deep leiomyomas. CONCLUSION: Endoscopic ultrasonography has demonstrated high accuracy in the diagnosis of esophageal leiomyomas and provides great support in selecting treatments; however, EUS cannot completely

  20. [Imaging of hyperparathyroidism-Ultrasonography and 99mTc-MIBI scintigraphy-].

    Science.gov (United States)

    Kawabe, Joji; Higashiyama, Shigeaki; Yoshida, Atsushi; Kotani, Kohei; Shiomi, Susumu

    2016-06-01

    Treatments for primary hyperparathyroidism due to adenoma, hyperplasia and carcinoma and secondary hyperparathyroidism are mainly surgical resections of them. Accurate imaging diagnoses of the existences and the regions are very important for reductions of invasiveness. We describe ultrasonography and (99m)Tc-MIBI scintigraphy of hyperparathyroidism. We explain an advantage, a disadvantage and diagnosability of these modalities. We mention utilities of SPECT/CT, too. We show echogram and (99m)Tc-MIBI scintigraphy images about 3 cases of hyperparathyroidism.

  1. Comparison between doppler ultrasonography and renal scintigraphy in assessment of post-transplant renal function

    International Nuclear Information System (INIS)

    Yoon, Yeo Chang; Shin, Byung Seok; Ohm, Joon Young; Kim, Seong Min; Ahn, Moon Sang; Yang, Shin Seok; Park, Mi Hyun

    2016-01-01

    To compare the usefulness of Doppler ultrasonography and renal scintigraphy in the assessment of short- and long-term function of transplanted kidneys. We retrospectively reviewed the cases of 79 patients who underwent Doppler ultrasonography and technetium-99m diethylene triamine pentaacetic acid renal scintigraphy on the same day, within 4 days of renal transplantation. Image parameters were evaluated for statistical differences. There was a strong positive correlation between the glomerular filtration rate (GFR) as measured by renal scintigraphy and the estimated GFR (eGFR) based on serum creatinine levels (correlation coefficient = 0.71). Scan grade according to the time-activity curve, resistive index, and end diastolic velocity showed moderate correlations with the eGFR (correlation coefficients = -0.557, -0.329, and 0.370, respectively) in the early post-transplantation period. The mean survival time was longer in patients with lower resistive indices (≤ 0.68, 54.9 months vs. > 0.68, 29.5 months) and lower pulsatility indices (≤ 1.32, 53.8 months vs. > 1.32, 28.7 months); however, there were no statistically significant differences in the long-term follow-up period (p = 0.121 for resistive index and p = 0.074 for pulsatility index). Renal scintigraphy is a more sensitive method than Doppler ultrasonography for assessing transplanted kidney function in the early post-transplantation period. Doppler ultrasonography might reflect the long-term survival time. However, it is difficult to predict long-term renal function using either method

  2. Transabdominal color doppler ultrasonography: A relevant approach for assessment of effects of uterine torsion in buffaloes

    Directory of Open Access Journals (Sweden)

    Devender

    2016-08-01

    Full Text Available Aim: The present study was conducted on advanced pregnant buffaloes suffering from uterine torsion to assess the status of fetus and uterus by transabdominal ultrasonography, and the findings were compared with normal advanced pregnant buffaloes. Materials and Methods: The study was conducted on 20 clinical cases of uterine torsion and 20 normal advanced pregnant buffaloes (control group. The lower ventral area just lateral to linea alba (on both sides of the udder in standing animals was scanned transabdominally by the two-dimensional convex transducer for various ultrasonographic findings. The data collected were statistically analyzed by “one-way ANOVA” and “independent sample t-test” using computerized SPSS 16.0 software program. Results: Transabdominal ultrasonography revealed dead fetus in 95% uterine torsion cases and proved useful in imaging internal structures of fetuses while no dead fetus was reported in the control group. Size of umbilicus was found significantly decreased (p0.05 in uterine torsion group. Average thickness of the uterine wall and mean pixel values of fetal fluids (echogenicity were found significantly increased (p<0.05 in uterine torsion affected buffaloes in comparison to control group. Conclusion: Status of fetus (whether live or dead, internal status of uterus, and its contents could be determined by transabdominal ultrasonography in uterine torsion cases and thus determining the prognosis of the uterine torsion cases before going for further manipulations. This will also help in taking all the precautions to avoid death of the fetus.

  3. Applications of Ultrasonography in Female Lower Urinary Tract Symptoms: Diagnosis and Intervention

    Directory of Open Access Journals (Sweden)

    Wen-Chen Huang

    2004-09-01

    Full Text Available Lower urinary tract symptoms (LUTS are a common health problem causing considerable inconvenience to many women. Moreover, they are non-specific and can be caused by a large number of disorders. A thorough evaluation, including physical examination, imaging studies, and urodynamic investigation of the lower urinary tract, is crucial for appropriate management of bothersome symptoms. Ultrasonography has the advantages of non-invasiveness, reproducibility, no radiation exposure, and low cost. With the use of a high-resolution transducer, pelvic organs can be demonstrated clearly on ultrasonography. In addition, three-dimensional sonography provides a clear demonstration of the spatial orientation of the female lower urinary tract. Both color and power Doppler scanning can not only reveal the vascular flow in pelvic organs, but also demonstrate urinary flow. Ultrasonography has dual functions in the management of female LUTS: diagnosis and intervention. It may help physicians to recognize the anatomic characteristics of specific pelvic floor disorders, to explore the pathophysiologic mechanism responsible for pelvic floor dysfunction, and to assist in the surgical management of LUTS with minimal invasion. Since female LUTS may originate from gynecologic or nongynecologic conditions, it is more convenient and helpful to obtain transvaginal and introital sonograms at the same time by using an endovaginal probe.

  4. Return to contact sports following infectious mononucleosis: the role of serial ultrasonography.

    Science.gov (United States)

    O'Connor, Tony E; Skinner, Liam J; Kiely, Patrick; Fenton, John E

    2011-08-01

    Splenic rupture is a rare but potentially fatal complication of infectious mononucleosis. Athletes returning to contact sports following infectious mononucleosis are at potential risk of splenic rupture secondary to abdominal trauma. No clear consensus exists as to when it is safe to allow these athletes to return to contact sports. Suggested periods of abstinence have ranged from 2 weeks to 6 months. We outline our experiences with the use of abdominal ultrasonography at 1 month after the diagnosis of infectious mononucleosis as a means of determining when athletes can safely return to contact sports. Our study group was made up of 19 such patients (mean age: 16.7 yr). We found that 16 of these patients (84%) had normal splenic dimensions on ultrasonography 1 month after diagnosis, and they were therefore allowed to return to contact sports. While the remaining 3 patients had an enlarged spleen at 1 month, their splenic dimensions had all returned to normal when ultrasonographic examination was repeated at 2 months postdiagnosis. We conclude that serial abdominal ultrasonography allows for informed decision making in determining when athletes can safely return to contact sports following infectious mononucleosis.

  5. Comparison of cone-beam computed tomography and ultrasonography on experimental bone lesion

    International Nuclear Information System (INIS)

    Kim, Min Sung; Park, Cheol Woo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2010-01-01

    This study was performed to evaluate the diagnostic ability of ultrasonography in detection of bone defects and new bone formation. Experimental bony defects were prepared on the parietal bone samples acquired from 3.5 kg New Zealand male rabbits. The defects were evaluated using ultrasonography and CBCT, and examined histologically at interval of 1, 3, 6, and 8 weeks. Ultrasonograph demonstrated hyperechogenicity in the defect area at 3 weeks and broadened hyperechogenicity from the margin of bone defect at 6 and 8 weeks due to new bone formation. On the CBCT images, new bone formation was first observed at 3 weeks around the margin of the defect, and showed gradually increase at 6 and 8 weeks. Histologic findings revealed existence of the fibroblasts and fibrous connective tissue with abundant capillary vessels only at 1 week, but osteoid tissue and newly formed trabecular bone at 3 weeks. Bone remodeling in the defect area was observed at 6 weeks and increased calcification and dense trabecular bone formation was observed at 8 weeks. Ultrasonograph proved to be a very useful diagnostic tool in detecting the bony defect and new bone formation. Additionally, ultrasonography provided valuable information regarding the blood supply around the defect area.

  6. Efficacy of ultrasonography-guided renal biopsy for the evaluation of renal dysfunction following renal transplantation

    International Nuclear Information System (INIS)

    Kim, Young Jae; Choi, Chul Soon; Min, Seon Jeong; Lee, Gyung Kyu; Lee, Eil Seong; Kang, Ik Won; Bae, Sang Hoon

    2003-01-01

    To evaluate the usefulness and complications of renal biopsy under ultrasonography-guidance in renal dysfunction after renal transplantation. Ultrasonography-guided renal biopsy was done in 47 patients with the transplanted kidney. The subjects consisted of 30 males and 17 females, age ranged from 16 to 66 years (average age=38 years). Biopsies were done once in 27 patients, twice in 17 patients, three times in 3 patients, a total of 70 biopsies. The success rate of renal biopsy for the accurate pathologic diagnosis and the incidence and types of complications following biopsy were evaluated. The success rate of renal biopsy for the accurate pathologic diagnosis was 96%(67/70). Pathologic diagnosis included 27 cases of acute rejection (39%), 8 cases of acute tubular necrosis (11%), 4 cases of acute rejection and acute tubular necrosis (6%), 4 cases of cyclosporin toxicity (6%), 4 cases of primary disease recurrence (6%), 4 cases of infection (6%) and others. Complications after renal biopsy included 15 cases of microscopic hematuria (21%), 1 case of gross hematuria with spontaneous cessation and 1 case of life threatening hemorrhage. Ultrasonography-guided renal biopsy is a safe and effective diagnostic method for the evaluation of renal dysfunction following renal transplantation.

  7. Efficacy of ultrasonography-guided shoulder MR arthrography using a posterior approach

    Energy Technology Data Exchange (ETDEWEB)

    Gokalp, Gokhan; Dusak, Abdurrahim; Yazici, Zeynep [Uludag University Medical Faculty, Goeruekle Kampusu, Department of Radiology, Bursa (Turkey)

    2010-06-15

    Shoulder MR arthrography has an important role in the assessment of rotator cuff lesions, labral tears, glenohumeral ligaments, rotator interval lesions, and postoperative shoulder status. Injection in direct MR arthrography can be performed with palpation, fluoroscopy, ultrasonography (US), or MRI. Recently, the posterior approach is the preferred method due to the presence of fewer stabilizers, absence of important articular structures and less extravasation, has been advocated. Our aim was to assess the efficacy of US-guided MR arthrography via a posterior approach on the glenohumeral joint. Thirty MR arthrographies were performed on 29 patients. Ultrasonography (Xario, Toshiba) examinations were conducted by a wide-band 5-12 Mhz linear array transducer set to muscle-skeleton. Diluted contrast medium (1 ml gadolinium chelate and 100 ml saline, approximately 15 ml) was delivered into the glenohumeral joint space from between the humeral head and posterior labrum with a 20-gauge spinal needle. MRI examination was conducted by a 1.5 T scanner. Fat-saturated T1-weighted spin echo was applied on coronal, axial, and sagittal planes within the first 30 min after contrast material injection. One (3.3%) arthrography was not successful due to technical reasons associated with obesity. Contrast extravasation around the infraspinatus and teres minoer muscles was depicted in twelve examinations. One (3.3%) patient developed vasovagal collapse. Ultrasonography-guided posterior approach is an easy, reliable, fast, and comfortable method in experienced hands. It may be an alternative for fluoroscopy-guided shoulder MR arthrography. (orig.)

  8. Clinical application of transcranial Doppler ultrasonography in premature, very-low-birth-weight neonates

    International Nuclear Information System (INIS)

    Gabriel, Marta Lucia; Souza, Antonio Soares

    2010-01-01

    Objective: the present study was aimed at analyzing the value of the early diagnosis of hemodynamic changes in hemorrhages and hypoxic-ischemic events in premature, very-low-birth-weight neonates through the evaluation of images and resistance index measurement by means of transcranial Doppler ultrasonography. Materials and methods: fifty premature, very-low-birth-weight neonates were submitted to transcranial Doppler ultrasonography with sequential transfontanellar and transtemporal techniques. Results: cerebral abnormalities were detected in 32% of the neonates (22% with intracranial hemorrhage, 8% with periventricular leukomalacia, and 2% with toxoplasmosis). Among the 34 cases (68%) of neonates in whom no brain lesion was detected at transcranial Doppler ultrasonography, 18 (53%) presented changes in the resistance index. Such resistance index varied according to the time of the examination. Conclusion: there is a correlation between the presence of cerebral hemodynamic changes demonstrated by resistance index measurements and the subsequent development of hemorrhages and hypoxic-ischemic lesions. Although not being a death predictor, changes in the resistance index are associated with the severity of the clinical conditions in preterm, very-low-birth-weight neonates. (author)

  9. Evaluation of transurethral ultrasonography and computed tomography in the staging of bladder tumors

    International Nuclear Information System (INIS)

    Yamakawa, Kensuke; Hoshina, Akira; Tochigi, Hiromi; Kawamura, Juichi

    1987-01-01

    A definitive pathologic diagnosis was made in 47 patients with bladder tumors from cystectomy specimens or by surgical exploration. The tumor was staged in 35 cases by transurethral ultrasonography and in 39 cases by computed tomography. We obtained the following results : the accuracy was 83 % using transurethral sonography, 77 % using computed tomography. Although transurethral ultrasonography is more advantageous than computed tomography in the low stage in regard to accuracy, computed tomography is excellent method to obtain information about the tumor invasion and/or metastases. Of 25 cases combind with computed tomography and transurethral sonography. tumors were correctly staged by both methods in 18 cases (72 %). Histopathological stage was consistent with neither ultrasonographic stage nor computed tomographic stage in 2 cases, and any of these tumors was correctly staged by either of these methods. Although transurethral ultrasonography and computed tomography improve the clinical stage of the bladder tumors separately, some limitations and problems was recognized on using together with these methods for staging the bladder tumors. (author)

  10. Efficacy of ultrasonography-guided shoulder MR arthrography using a posterior approach

    International Nuclear Information System (INIS)

    Gokalp, Gokhan; Dusak, Abdurrahim; Yazici, Zeynep

    2010-01-01

    Shoulder MR arthrography has an important role in the assessment of rotator cuff lesions, labral tears, glenohumeral ligaments, rotator interval lesions, and postoperative shoulder status. Injection in direct MR arthrography can be performed with palpation, fluoroscopy, ultrasonography (US), or MRI. Recently, the posterior approach is the preferred method due to the presence of fewer stabilizers, absence of important articular structures and less extravasation, has been advocated. Our aim was to assess the efficacy of US-guided MR arthrography via a posterior approach on the glenohumeral joint. Thirty MR arthrographies were performed on 29 patients. Ultrasonography (Xario, Toshiba) examinations were conducted by a wide-band 5-12 Mhz linear array transducer set to muscle-skeleton. Diluted contrast medium (1 ml gadolinium chelate and 100 ml saline, approximately 15 ml) was delivered into the glenohumeral joint space from between the humeral head and posterior labrum with a 20-gauge spinal needle. MRI examination was conducted by a 1.5 T scanner. Fat-saturated T1-weighted spin echo was applied on coronal, axial, and sagittal planes within the first 30 min after contrast material injection. One (3.3%) arthrography was not successful due to technical reasons associated with obesity. Contrast extravasation around the infraspinatus and teres minoer muscles was depicted in twelve examinations. One (3.3%) patient developed vasovagal collapse. Ultrasonography-guided posterior approach is an easy, reliable, fast, and comfortable method in experienced hands. It may be an alternative for fluoroscopy-guided shoulder MR arthrography. (orig.)

  11. Clinical application of transcranial Doppler ultrasonography in premature, very-low-birth-weight neonates

    Energy Technology Data Exchange (ETDEWEB)

    Gabriel, Marta Lucia [Fundacao Faculdade Regional de Medicina (FUNFARME), Sao Jose do Rio Preto, SP (Brazil). Hospital de Base; Piatto, Vania Belintani [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil); Souza, Antonio Soares, E-mail: depimagem@famerp.b [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Dept. de Diagnostico por Imagem

    2010-07-15

    Objective: the present study was aimed at analyzing the value of the early diagnosis of hemodynamic changes in hemorrhages and hypoxic-ischemic events in premature, very-low-birth-weight neonates through the evaluation of images and resistance index measurement by means of transcranial Doppler ultrasonography. Materials and methods: fifty premature, very-low-birth-weight neonates were submitted to transcranial Doppler ultrasonography with sequential transfontanellar and transtemporal techniques. Results: cerebral abnormalities were detected in 32% of the neonates (22% with intracranial hemorrhage, 8% with periventricular leukomalacia, and 2% with toxoplasmosis). Among the 34 cases (68%) of neonates in whom no brain lesion was detected at transcranial Doppler ultrasonography, 18 (53%) presented changes in the resistance index. Such resistance index varied according to the time of the examination. Conclusion: there is a correlation between the presence of cerebral hemodynamic changes demonstrated by resistance index measurements and the subsequent development of hemorrhages and hypoxic-ischemic lesions. Although not being a death predictor, changes in the resistance index are associated with the severity of the clinical conditions in preterm, very-low-birth-weight neonates. (author)

  12. The color Doppler ultrasonography in in the diagnosis of deep vein thrombosis

    International Nuclear Information System (INIS)

    Ameneiro Perez, Santiago; Alvarez Sanchez, Jose A.; Rodriguez Villalonga, Luis; Borras Migues, Marisela; Quinnones Castro, Mayda

    2004-01-01

    The paper was aimed at evaluating the accuracy of color Doppler ultrasonography, a noninvasive method, in the diagnosis of deep vein thrombosis of the lower limbs, comparing it to the results of the cruel and costly diagnostic g olden rule , that is, phlebography. Methods: Color Doppler ultrasonography served to assess 102 patients clinically suspected of deep vein thrombosis of the lower limbs, taking into account the following criteria: vein compressibility, echographic images, color, Vein Doppler signal modulation after several maneuvers and distal compression. Sensitivity, specificity, positive and negative predictive values and diagnostic efficacy were estimated for each criteria, taking the phlebography as a reference. Results: Total or partial lack of vein compressibility combined with the vein flow evaluation is the ultrasonographic criterion that reveals higher degree of sensitivity, specificity and efficacy (0,98; 0,95 and 0,97 respectively. Color Doppler ultrasonography is a highly effective noninvasive diagnostic method that detects deep vein thrombosis in proximal areas of the lower limbs

  13. Ultrasonography as an ancillary method for the positioning of markers in equine motion analysis

    Directory of Open Access Journals (Sweden)

    Luanna Ferreira Fasanelo Gomes

    2014-08-01

    Full Text Available Kinematic motion analysis is based on the reconstruction of selected bony anatomical landmarks identified by surface markers. Anatomical landmarks generally do not correspond to points but rather to relatively large and curved areas and their identification by palpation is not easy. Precise placement of surface markers is even more difficult and there is great variability between operators. In this study 16 examiners were asked to identify the lateral border of the left ischial tuberosity in a horse using palpation and ultrasonography for placement of a corresponding skin surface marker. Images of each marking procedure were captured using two video cameras and processed using the DVideow videogrammetry. A custom-written Matlab code was used to determine the position of the respective vectors. The positions of the markers were then compared to assess inter-examiner variability and the precision of the methods employed using the Bartletttest and the paired t-test respectively. Ultrasonography significantly improved the location of the anatomical landmark by each examiner (p = 0.04 and reduced the variability in the position of the surface marker when compared to palpation (p = 0.0028. The variability of the calculated distances (mean ± SD was 2.89 ± 2.24 cm and 1.63 ± 0.98 cm using palpation and ultrasonography respectively. Ultrasound guidance reduced inter-examiner variability and allowed visualization of the corresponding bony anatomical landmark.

  14. The Significance Ultrasonography on the Evaluation of Ovarian Follicular Maturity and Growth

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kab Tae; Kim, Ok Keun; Lee, Seok Hong; Kim, Tae Seon; Kim, Byung Soo [Pusan National University College of Medicine, Busan (Korea, Republic of)

    1987-12-15

    Ovarian follicular diameter was measured using real time ultrasound in 21 hyperstimulated patients from April to September 1986. And we analyzed the relation between the size measured with ultrasonography and maturity observed under the phased microscopy, the correlation between aspirated dominant follicular volume and the dominant follicular volume calculated by the size measured with ultrasonography. Also we experienced the conditions which showed the ultrasonographic finding similar to that of follicle. The results were as follows: 1. The mean follicular diameter increased in a linear fashion from 7 days after LMP (9.4mm+2.8)to the one day before ovum pick up(18.2+2.8). 2. The mean diameter of the most appropriate dominant follicle was 19.08+1.23mm 3. The correlation between the dominant follicular volume measured with ultrasonography and aspirated follicular volume during ovum pick up was highly significant(r=0.94;0<0.001). 4. during follicular growth and maturity monitoring the conditions which misdiagnosed of follicle were simple ovarian cyst(1 case), hydrosalpinx (1 case), endometriosis(1 case), tubo-ovarian abscess(1 case), Hydatid of Morgagni(1 case)

  15. Ultrasonography as a diagnostic tool in assessing deltoid ligament injury in supination external rotation fractures of the ankle.

    LENUS (Irish Health Repository)

    Henari, Shwan

    2011-10-01

    The medial deltoid ligament is the primary stabilizing structure in the ankle joint following lateral malleolar fracture. However, medial deltoid ligament ruptures are difficult to diagnose using current imaging modalities. We hypothesized that ultrasonography can be used to accurately allow early clinical assessment of ankle fracture stability, thereby negating the need to perform plain film stress views of the acutely injured ankle. This prospective study included 12 patients (age range, 18-72) with supination external rotation fractures requiring operative fixation. Following induction of anesthesia, ultrasonography examination was performed, followed by an arthrogram under fluoroscopic screening. Radiographs, ultrasonography, and arthrographic findings were compared. There was 100% correlation between ultrasonography and arthrogram findings. Ultrasonography accurately diagnosed medial deltoid rupture with a sensitivity of 100% and specificity of 100%. Plain film radiographs of the ankle had a sensitivity of 57.1% and a specificity of 60%. The difference between these was significant (χ(2)=.0091). This study demonstrates diagnostic ultrasonography to be an accurate diagnostic modality in assessing medial deltoid ligament integrity in patients with supination external rotation fractures. It offers the same sensitivity and specificity as arthrography without the need for additional invasive procedures. Its relative ease of use and lack of ionizing radiation make it a potentially useful tool, particularly in a busy trauma service.

  16. Study on the Usefulness of Ultrasonography for Postpartum Depression and Thyroid Disease

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yun Yi; Lim, Cheong Hwan; Jung, Hong Ryang; Park, Mi Ja; You, In Gyu [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of)

    2012-09-15

    Postpartum depression(PPD) of women with depression increased frequency of thyroid disease, and so the correlations for depression and thyroid disease has been the subject of discussed whether. The purpose of this study was to predict the prevalence of PPD and the correlation between PPD and thyroid disease through ultrasonography. January 2010 to November 2011, Obstetrics and Gynecology in M-clinical center admitted 230 patients within 1 year postpartum were enrolled. EPDS by PPD scale depression screening and general characteristics of subjects were investigated and thyroid was examined that ultrasonography and thyroid blood tests. A total of 230 patients non PPD group were 53.0% and PPD group were 47.0%. In ultrasonography, among 27 patients who changed in size of thyroid, non PPD group were 14.8% and PPD group were 85.2%. Among 124 patients who thyroid nodules were presence, non PPD were 35.8% and PPD group were 64.2%. In ultrasonography, PPD group were higher incidence than non PPD group were changes in size of thyroid and the presence of nodules. There was significant difference between the changed in size of thyroid and thyroid nodules were presence the two group. Definitive histopathological diagnosis was benign in 33 patients (non PPD group were 45.5%, PPD group were 54.5%), malignancy in 5 patients (only PPD group were 100%), thyroiditis in 3 patients (non PPD group were 33.3%, PPD group were 66.7%). The results of thyroid blood tests, abnormal TSH level were 7 patients (non PPD group were 28.6%, PPD group were 71.4%) and abnormal Free T4 level were 9 patients (non PPD group were 44.4%, PPD group were 55.6%). There was no significant difference between the abnormal TSH level and Free T4 level of the two group. 5 patients were diagnosed as thyroid dysfunction. Of these, 2 patients were subclinical hyperthyroidism in non PPD group, 2 patients were subclinical hyperthyroidism and 1 patient was subclinical hyperthyroidism in PPD group. This study was

  17. Study on the Usefulness of Ultrasonography for Postpartum Depression and Thyroid Disease

    International Nuclear Information System (INIS)

    Lee, Yun Yi; Lim, Cheong Hwan; Jung, Hong Ryang; Park, Mi Ja; You, In Gyu

    2012-01-01

    Postpartum depression(PPD) of women with depression increased frequency of thyroid disease, and so the correlations for depression and thyroid disease has been the subject of discussed whether. The purpose of this study was to predict the prevalence of PPD and the correlation between PPD and thyroid disease through ultrasonography. January 2010 to November 2011, Obstetrics and Gynecology in M-clinical center admitted 230 patients within 1 year postpartum were enrolled. EPDS by PPD scale depression screening and general characteristics of subjects were investigated and thyroid was examined that ultrasonography and thyroid blood tests. A total of 230 patients non PPD group were 53.0% and PPD group were 47.0%. In ultrasonography, among 27 patients who changed in size of thyroid, non PPD group were 14.8% and PPD group were 85.2%. Among 124 patients who thyroid nodules were presence, non PPD were 35.8% and PPD group were 64.2%. In ultrasonography, PPD group were higher incidence than non PPD group were changes in size of thyroid and the presence of nodules. There was significant difference between the changed in size of thyroid and thyroid nodules were presence the two group. Definitive histopathological diagnosis was benign in 33 patients (non PPD group were 45.5%, PPD group were 54.5%), malignancy in 5 patients (only PPD group were 100%), thyroiditis in 3 patients (non PPD group were 33.3%, PPD group were 66.7%). The results of thyroid blood tests, abnormal TSH level were 7 patients (non PPD group were 28.6%, PPD group were 71.4%) and abnormal Free T4 level were 9 patients (non PPD group were 44.4%, PPD group were 55.6%). There was no significant difference between the abnormal TSH level and Free T4 level of the two group. 5 patients were diagnosed as thyroid dysfunction. Of these, 2 patients were subclinical hyperthyroidism in non PPD group, 2 patients were subclinical hyperthyroidism and 1 patient was subclinical hyperthyroidism in PPD group. This study was

  18. Diagnostic Accuracy of Ultrasonography and Radiography in Initial Evaluation of Chest Trauma Patients.

    Science.gov (United States)

    Vafaei, Ali; Hatamabadi, Hamid Reza; Heidary, Kamran; Alimohammadi, Hosein; Tarbiyat, Mohammad

    2016-01-01

    Application of chest radiography for all multiple trauma patients is associated with a significant increase in total costs, exposure to radiation, and overcrowding of the emergency department. Ultrasound has been introduced as an alternative diagnostic tool in this regard. The aim of the present study is to compare the diagnostic accuracy of chest ultrasonography and radiography in detection of traumatic intrathoracic injuries. In the present prospective cross-sectional study, patients with traumatic intrathoracic injuries, who were referred to the emergency department from December 2013 to December 2014, were assessed. The patients underwent bedside ultrasound, radiographic and computed tomography (CT) scan examinations based on ATLS recommendations. Screening performance characteristics of ultrasonography and radiography were compared using SPSS 21.0. Chest CT scan was considered as gold standard. 152 chest trauma patients with a mean age of 31.4 ± 13.8 years (range: 4 ‒ 67), were enrolled (77.6% male). Chest CT scan showed pulmonary contusion in 48 (31.6%) patients, hemothorax in 29 (19.1%), and pneumothorax in 55 (36.2%) cases. Area under the ROC curve of ultrasonography in detection of pneumothorax, hemothorax, and pulmonary contusion were 0.91 (95% CI: 0.86‒0.96), 0.86 (95% CI: 0.78‒0.94), and 0.80 (95% CI: 0.736‒0.88), respectively. Area under the ROC curve of radiography was 0.80 (95% CI: 0.736‒0.87) for detection of pneumothorax, 0.77 (95% CI: 0.68‒0.86) for hemothorax, and 0.58 (95% CI: 0.5‒0.67) for pulmonary contusion. Comparison of areas under the ROC curve declared the significant superiority of ultrasonography in detection of pneumothorax (p = 0.02) and pulmonary contusion (p < 0.001). However, the diagnostic value of the two tests was equal in detection of hemothorax (p = 0.08). The results of the present study showed that ultrasonography is preferable to radiography in the initial evaluation of patients with traumatic injuries to the

  19. Diagnostic Accuracy of Ultrasonography and Radiography in Initial Evaluation of Chest Trauma Patients

    Directory of Open Access Journals (Sweden)

    Ali Vafaei

    2016-01-01

    Full Text Available Introduction: Application of chest radiography for all multiple trauma patients is associated with a significant increase in total costs, exposure to radiation, and overcrowding of the emergency department. Ultrasound has been introduced as an alternative diagnostic tool in this regard. The aim of the present study is to compare the diagnostic accuracy of chest ultrasonography and radiography in detection of traumatic intrathoracic injuries. Methods: In the present prospective cross-sectional study, patients with traumatic intrathoracic injuries, who were referred to the emergency department from December 2013 to December 2014, were assessed. The patients underwent bedside ultrasound, radiographic and computed tomography (CT scan examinations based on ATLS recommendations. Screening performance characteristics of ultrasonography and radiography were compared using SPSS 21.0. Chest CT scan was considered as gold standard. Results: 152 chest trauma patients with a mean age of 31.4 ± 13.8 years (range: 4 ‒ 67, were enrolled (77.6% male. Chest CT scan showed pulmonary contusion in 48 (31.6% patients, hemothorax in 29 (19.1%, and pneumothorax in 55 (36.2% cases. Area under the ROC curve of ultrasonography in detection of pneumothorax, hemothorax, and pulmonary contusion were 0.91 (95% CI: 0.86‒0.96, 0.86 (95% CI: 0.78‒0.94, and 0.80 (95% CI: 0.736‒0.88, respectively. Area under the ROC curve of radiography was 0.80 (95% CI: 0.736‒0.87 for detection of pneumothorax, 0.77 (95% CI: 0.68‒0.86 for hemothorax, and 0.58 (95% CI: 0.5‒0.67 for pulmonary contusion. Comparison of areas under the ROC curve declared the significant superiority of ultrasonography in detection of pneumothorax (p = 0.02 and pulmonary contusion (p < 0.001. However, the diagnostic value of the two tests was equal in detection of hemothorax (p = 0.08. Conclusion: The results of the present study showed that ultrasonography is preferable to radiography in the initial

  20. Diagnostic sensitivity and interobserver agreement of radiography and ultrasonography for detecting trochlear ridge osteochondrosis lesions in the equine stifle.

    Science.gov (United States)

    Beccati, Francesca; Chalmers, Heather J; Dante, Sara; Lotto, Eleonora; Pepe, Marco

    2013-01-01

    Osteochondrosis lesions commonly occur on the femoral trochlear ridges in horses and radiography and ultrasonography are routinely used to diagnose these lesions. However, poor correlation has been found between radiographic and arthroscopic findings of affected trochlear ridges. Interobserver agreement for ultrasonographic diagnoses and correlation between ultrasonographic and arthroscopic findings have not been previously described. Objectives of this study were to describe diagnostic sensitivity and interobserver agreement of radiography and ultrasonography for detecting and grading osteochondrosis lesions of the equine trochlear ridges, using arthroscopy as the reference standard. Twenty-two horses were sampled. Two observers independently recorded radiographic and ultrasonographic findings without knowledge of arthroscopic findings. Imaging findings were compared between observers and with arthroscopic findings. Agreement between observers was moderate to excellent (κ 0.48-0.86) for detecting lesions using radiography and good to excellent (κ 0.74-0.87) for grading lesions using radiography. Agreement between observers was good to excellent (κ 0.78-0.94) for detecting lesions using ultrasonography and very good to excellent (κ 0.86-0.93) for grading lesions using ultrasonography. Diagnostic sensitivity was 84-88% for radiography and 100% for ultrasonography. Diagnostic specificity was 89-100% for radiography and 60-82% for ultrasonography. Agreement between radiography and arthroscopy was good (κ 0.64-0.78). Agreement between ultrasonography and arthroscopy was very good to excellent (κ 0.81-0.87). Findings from this study support ultrasound as a preferred method for predicting presence and severity of osteochondrosis lesions involving the femoral trochlear ridges in horses. © 2012 Veterinary Radiology & Ultrasound.