WorldWideScience

Sample records for ultrasonography eus computed

  1. Impact of endoscopic ultrasonography (EUS) on surgical decision-making in upper gastrointestinal tract cancer

    DEFF Research Database (Denmark)

    Mortensen, Michael Bau; Edwin, B; Hünerbein, M

    2007-01-01

    BACKGROUND: Endoscopic ultrasonography (EUS) is an integrated part of the pretherapeutic evaluation program for patients with upper gastrointestinal (GI) tract cancer. Whether the clinical impact of EUS differs between surgeons from different countries is unknown. The same applies to the potential...... clinical influence of EUS misinterpretations. The aim of this study was to evaluate the interobserver agreement on predefined treatment strategies between surgeons from four different countries, with and without EUS, and to evaluate the clinical consequences of EUS misinterpretations. METHODS: One hundred...... patients with upper GI tract cancer were randomly selected from all upper GI tract cancer patients treated at Odense University Hospital between 1997 and 2000. Based on patient records and EUS database results, a case story was created with and without the EUS result for each patient. Four surgeons were...

  2. Diagnostic accuracy of endoscopic ultrasonography (EUS) for the preoperative locoregional staging of primary gastric cancer.

    Science.gov (United States)

    Mocellin, Simone; Pasquali, Sandro

    2015-02-06

    Endoscopic ultrasound (EUS) is proposed as an accurate diagnostic device for the locoregional staging of gastric cancer, which is crucial to developing a correct therapeutic strategy and ultimately to providing patients with the best chance of cure. However, despite a number of studies addressing this issue, there is no consensus on the role of EUS in routine clinical practice. To provide both a comprehensive overview and a quantitative analysis of the published data regarding the ability of EUS to preoperatively define the locoregional disease spread (i.e., primary tumor depth (T-stage) and regional lymph node status (N-stage)) in people with primary gastric carcinoma. We performed a systematic search to identify articles that examined the diagnostic accuracy of EUS (the index test) in the evaluation of primary gastric cancer depth of invasion (T-stage, according to the AJCC/UICC TNM staging system categories T1, T2, T3 and T4) and regional lymph node status (N-stage, disease-free (N0) versus metastatic (N+)) using histopathology as the reference standard. To this end, we searched the following databases: the Cochrane Library (the Cochrane Central Register of Controlled Trials (CENTRAL)), MEDLINE, EMBASE, NIHR Prospero Register, MEDION, Aggressive Research Intelligence Facility (ARIF), ClinicalTrials.gov, Current Controlled Trials MetaRegister, and World Health Organization International Clinical Trials Registry Platform (WHO ICTRP), from 1988 to January 2015. We included studies that met the following main inclusion criteria: 1) a minimum sample size of 10 patients with histologically-proven primary carcinoma of the stomach (target condition); 2) comparison of EUS (index test) with pathology evaluation (reference standard) in terms of primary tumor (T-stage) and regional lymph nodes (N-stage). We excluded reports with possible overlap with the selected studies. For each study, two review authors extracted a standard set of data, using a dedicated data extraction

  3. Endoscopic ultrasonography and computed tomography scanning for preoperative staging of colonic cancer

    DEFF Research Database (Denmark)

    Malmstrøm, M L; Gögenur, I; Riis, L B

    2017-01-01

    PURPOSE: With an increasing demand for more accurate preoperative staging methods for colon cancer, we aimed to compare preoperative tumour (T)- and nodal (N)-stage in patients with left-sided colon cancer by endoscopic ultrasonography (EUS) and computed tomography (CT) with post......-operative histology as gold standard. METHODS: A total of 44 patients were prospectively recruited at Herlev and Roskilde University Hospitals during November 2014-January 2016. Thirty-five patients were included in the final analysis and underwent EUS, CT and surgery within 2 weeks. Diagnostic values were evaluated...... difficult to evaluate due to small patient numbers. EUS could be considered as a supplement to CT scans in selecting patients for neoadjuvant therapies, or local transmural treatment, in the future. TRIAL REGISTRATION: NCT02324023....

  4. Detection of common bile duct stones: comparison between endoscopic ultrasonography, magnetic resonance cholangiography, and helical-computed-tomographic cholangiography

    International Nuclear Information System (INIS)

    Kondo, Shintaro; Isayama, Hiroyuki; Akahane, Masaaki; Toda, Nobuo; Sasahira, Naoki; Nakai, Yosuke; Yamamoto, Natsuyo; Hirano, Kenji; Komatsu, Yutaka; Tada, Minoru; Yoshida, Haruhiko; Kawabe, Takao; Ohtomo, Kuni; Omata, Masao

    2005-01-01

    Objectives: New modalities, namely, endoscopic ultrasonography (EUS), magnetic resonance cholangiopancreatography (MRCP), and helical computed-tomographic cholangiography (HCT-C), have been introduced recently for the detection of common bile duct (CBD) stones and shown improved detectability compared to conventional ultrasound or computed tomography. We conducted this study to compare the diagnostic ability of EUS, MRCP, and HCT-C in patients with suspected choledocholithiasis. Methods: Twenty-eight patients clinically suspected of having CBD stones were enrolled, excluding those with cholangitis or a definite history of choledocholithiasis. Each patient underwent EUS, MRCP, and HCT-C prior to endoscopic retrograde cholangio-pancreatography (ERCP), the result of which served as the diagnostic gold standard. Results: CBD stones were detected in 24 (86%) of 28 patients by ERCP/IDUS. The sensitivity of EUS, MRCP, and HCT-C was 100%, 88%, and 88%, respectively. False negative cases for MRCP and HCT-C had a CBD stone smaller than 5 mm in diameter. No serious complications occurred while one patient complained of itching in the eyelids after the infusion of contrast agent on HCT-C. Conclusions: When examination can be scheduled, MRCP or HCT-C will be the first choice because they were less invasive than EUS. MRCP and HCT-C had similar detectability but the former may be preferable considering the possibility of allergic reaction in the latter. When MRCP is negative, EUS is recommended to check for small CBD stones

  5. Comparison of endoscopic ultrasonography and multislice spiral computed tomography for the preoperative staging of gastric cancer - results of a single institution study of 610 Chinese patients.

    Directory of Open Access Journals (Sweden)

    Xing-Yu Feng

    Full Text Available BACKGROUND: This study compared the performance of endoscopic ultrasonography (EUS and multislice spiral computed tomography (MSCT in the preoperative staging of gastric cancer. METHODOLOGY/PRINCIPAL FINDINGS: A total of 610 patients participated in this study, all of whom had undergone surgical resection, had confirmed gastric cancer and were evaluated with EUS and MSCT. Tumor staging was evaluated using the Tumor-Node-Metastasis (TNM staging and Japanese classification. The results from the imaging modalities were compared with the postoperative histopathological outcomes. The overall accuracies of EUS and MSCT for the T staging category were 76.7% and 78.2% (P=0.537, respectively. Stratified analysis revealed that the accuracy of EUS for T1 and T2 staging was significantly higher than that of MSCT (P<0.001 for both and that the accuracy of MSCT in T3 and T4 staging was significantly higher than that of EUS (P<0.001 and 0.037, respectively. The overall accuracy of MSCT was 67.2% when using the 13th edition Japanese classification, and this percentage was significantly higher than the accuracy of EUS (49.3% and MSCT (44.6% when using the 6th edition UICC classification (P<0.001 for both values. CONCLUSIONS/SIGNIFICANCE: Our results demonstrated that the overall accuracies of EUS and MSCT for preoperative staging were not significantly different. We suggest that a combination of EUS and MSCT is required for preoperative evaluation of TNM staging.

  6. Impact of Endoscopic Ultrasonography on (18)F-FDG-PET/CT Upfront Towards Patient Specific Esophageal Cancer Treatment

    NARCIS (Netherlands)

    Hulshoff, J. B.; Mul, V. E. M.; de Boer, H. E. M.; Noordzij, W.; Korteweg, T.; van Dullemen, H. M.; Nagengast, W. B.; Oppedijk, V.; Pierie, J. P. E. N.; Plukker, John Th. M.

    INTRODUCTION: In patients with potentially resectable esophageal cancer (EC), the value of endoscopic ultrasonography (EUS) after fluorine-18 labeled fluorodeoxyglucose positron emission tomography with computed tomography ((18)F-FDG-PET/CT) is questionable. Retrospectively, we assessed the impact

  7. Computed tomography of hepatocellular carcinoma. Comparison with scintigraphy and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Kuniyuki; Nakata, Hajime; Honda, Hiroshi [University of Occupational and Environmental Health, Kitakyushu, Fukuoka (Japan)

    1983-09-01

    The detectability of hepatocellular carcinoma by computed tomography (CT) was evaluated on 76 cases. The detectability by plain CT was 93% with only slight improvement following a drip infusion of contrast medium. A comparison of scintigraphy, ultrasonography, and CT was also done on 63 cases. From the standpoint of the overall detectability of the tumor, CT was as good as ultrasonography or scintigraphy. Several cases were positive only on either CT or ultrasonography but no case was positive on scintigraphy alone. We believe that the combination of CT and ultrasonography is the most reliable as the screening method.

  8. EUS Elastography: Advances in Diagnostic EUS of the Pancreas

    International Nuclear Information System (INIS)

    Lee, Tae Hee; Cha, Sang Woo; Cho, Young Deok

    2012-01-01

    Elastography is an imaging modality for the evaluation of tissue stiffness, which has been used for the analysis of superficial organs, such as those of the breast and prostate. The measurement of tissue elasticity has been reported to be useful for the diagnosis and differentiation of tumors, which are stiffer than normal tissues. Endoscopic ultrasonography elastography (EUS-EG) is a promising imaging technique with a high degree of accuracy for the differential diagnosis of solid pancreatic tumors. Recent introduction of second generation EUS-EG allows for the quantitative analysis of tissue stiffness. Here, we review our knowledge and preliminary experience with the use of EUS-elastography for the diagnosis of pancreatic disease.

  9. Role of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography in diagnosis and management of pancreatic cancer; comparison with multidetector row computed tomography, magnetic resonance imaging and endoscopic ultrasonography.

    Science.gov (United States)

    Ergul, N; Gundogan, C; Tozlu, M; Toprak, H; Kadıoglu, H; Aydin, M; Cermik, T F

    2014-01-01

    We aimed to analyze the contribution of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) imaging to the diagnosis and management of pancreatic cancer compared with multidetector row computed tomography (MDCT), magnetic resonance imaging (MRI) and endoscopic ultrasonography (EUS). We retrospectively scanned the data of 52 patients who were referred for FDG PET/CT imaging for evaluation of pancreatic lesions greater than 10mm. The diagnostic performances of 4 imaging methods and the impact of PET/CT on the management of pancreatic cancer were defined. Pancreatic adenocarcinoma was diagnosed in 33 of 52 patients (63%), 15 patients had benign diseases of pancreas (29%), and 4 patients were normal (8%). Sensitivity and NPV of EUS and PET/CT were equal (100%) and higher than MDCT and MRI. Specificity, PPV and NPV of PET/CT were significantly higher than MDCT. However, sensitivities of two imaging methods were not significantly different. There was no significant difference between PET/CT and MRI and EUS for these values. When the cut-off value of SUVmax was 3.2, the most effective sensitivity and specificity values were obtained. PET/CT contributed to the management of pancreatic cancer in 30% of patients. FDG PET/CT is a valuable imaging method for the diagnosis and management of pancreatic cancer, especially when applied along with EUS as first line diagnostic tools. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  10. Ultrasonography and computer tomography in the diagnosis of certain abdominal diseases

    International Nuclear Information System (INIS)

    Wawrzynek, Z.

    1981-01-01

    Ultrasonography and computer tomography in the diagnosis of digestive tract and spleen diseases as well as traumas are compared. It is concluded that ultrasonography is nearly as usefull as computer tomography. (author)

  11. Potentialities of computed tomography and ultrasonography in colonic cancer

    International Nuclear Information System (INIS)

    Gorshkov, A.N.

    2001-01-01

    Data of examination of 59 patients with colonic cancer were used to consider the potentialities of transabdominal, transrectal ultrasonography and X-ay compound tomography and to assess their value in diagnosing colonic cancer, including its minor forms. Ultrasound and computed tomographic semiotics of colonic cancer and determines a place of the above techniques in the algorithm of radiation and instrumental studies are described. Inclusion of these techniques into the diagnostic algorithm may solve a range of differentially diagnostic problems and allows a preliminary analysis to be made in a tumor lesion according to the International TNM classification. Ultrasonography and X-ray computed tomography should be included into a range of basic methods for diagnosis of colonic cancer [ru

  12. The role of routine preoperative EUS when performed after contrast enhanced CT in the diagnostic work-up in patients suspected of pancreatic or periampullary cancer.

    Science.gov (United States)

    Cieslak, Kasia P; van Santvoort, Hjalmar C; Vleggaar, Frank P; van Leeuwen, Maarten S; ten Kate, Fibo J; Besselink, Marc G; Molenaar, I Quintus

    2014-01-01

    In patients suspected of pancreatic or periampullary cancer, abdominal contrast-enhanced computed tomography (CT) is the standard diagnostic modality. A supplementary endoscopic ultrasonography (EUS) is often performed, although there is only limited evidence of its additional diagnostic value. The aim of the study is to evaluate the additional diagnostic value of EUS over CT in deciding on exploratory laparotomy in patients suspected of pancreatic or periampullary cancer. We retrospectively analyzed 86 consecutive patients who routinely underwent CT and EUS before exploratory laparotomy with or without pancreatoduodenectomy for suspected pancreatic or periampullary carcinoma between 2007 and 2010. Primary outcomes were visibility of a mass, resectability on CT/EUS and resection with curative intent. A mass was visible on CT in 72/86 (84%) patients. In these 72 patients, EUS demonstrated a mass in 64/72 (89%) patients. Resectability was accurately predicted by CT in 65/72 (90%) and by EUS in 58/72 (81%) patients. In 14/86 (16%) patients no mass was seen on CT. EUS showed a mass in 12/14 (86%) of these patients. A malignant lesion was histological proven in 11/12 (92%) of these patients. Overall, resectability was accurately predicted by CT and EUS in 90% (77/86) and 84% (72/86), respectively. In patients with a visible mass on CT, suspected for pancreatic or periampullary cancer, EUS has no additional diagnostic value, does not influence the decision to perform laparotomy and should therefore not be performed routinely. In patients without a visible mass on CT, EUS is useful to confirm the presence of a tumor. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  13. Comparative study of scintigraphy, ultrasonography and computed tomography in the evaluation of liver tumours

    International Nuclear Information System (INIS)

    Tohyama, Junko; Ishigaki, Takeo; Ishikawa, Tsutomu

    1982-01-01

    A comparative study of scintigraphy, ultrasonography and computed tomography in 67 proven patients with clinically suspected liver tumours was reported. Scintigraphy was superior in sensitivity to ultrasonography and computed tomography. However, in specificity, scintigraphy was inferior to other two. Diagnostic efficacy of ultrasonography and computed tomography in detecting focal masses of the liver was not greatly different, and simultaneous interpretation of ultrasonogram and computed tomogram was more helpful than independent interpretation. So they were thought to be complementary. In conclusion, scintigraphy was thought to be the initial procedure in the diagnostic approach for focal liver masses and ultrasonography was second procedure because of no radiation hazards. And computed tomography should follow then. (author)

  14. Usefulness of {sup 18}F-FDG PET, combined FDG-PET/CT and EUS in diagnosing primary pancreatic carcinoma: A meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Tang Shuang [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127 (China); Huang Gang, E-mail: huang2802@163.com [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127 (China); Liu Jianjun [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127 (China); Liu Tao [Department of Orthopedics, Soochow University, Suzhou (China); Treven, Lyndal [Faculty of Public Health, University of Sydney, Sydney (Australia); Song Saoli; Zhang Chenpeng; Pan Lingling [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127 (China); Zhang Ting [Department of Anesthesiology, Renji Hospital, Shanghai (China)

    2011-04-15

    The aim was to evaluate the diagnostic value of {sup 18}F-fluorodeoxyglucose-positron emission tomography ({sup 18}F-FDG PET), combined {sup 18}F-fluorodeoxyglucose-positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) and endoscopic ultrasonography (EUS) in diagnosing patients with pancreatic carcinoma. MEDLINE, EMBASE, Cochrane library and some other databases, from January 1966 to April 2009, were searched for initial studies. All the studies published in English or Chinese relating to the diagnostic value of {sup 18}F-FDG PET, PET/CT and EUS for patients with pancreatic cancer were collected. Methodological quality was assessed. The statistic software called 'Meta-Disc 1.4' was used for data analysis. Results: 51 studies were included in this meta-analysis. The pooled sensitivity estimate for combined PET/CT (90.1%) was significantly higher than PET (88.4%) and EUS (81.2%). The pooled specificity estimate for EUS (93.2%) was significantly higher than PET (83.1%) and PET/CT (80.1%). The pooled DOR estimate for EUS (49.774) was significantly higher than PET (32.778) and PET/CT (27.105). SROC curves for PET/CT and EUS showed a little better diagnostic accuracy than PET alone. For PET alone, when interpreted the results with knowledge of other imaging tests, its sensitivity (89.4%) and specificity (80.1%) were closer to PET/CT. For EUS, its diagnostic value decreased in differentiating pancreatic cancer for patients with chronic pancreatitis. In conclusion, PET/CT was a high sensitive and EUS was a high specific modality in diagnosing patients with pancreatic cancer. PET/CT and EUS could play different roles during different conditions in diagnosing pancreatic carcinoma.

  15. [Diagnostic utility of endoscopic ultrasonography elastography and contrast-enhanced harmonic endoscopic ultrasonography in a patient with type 2 autoimmune pancreatitis].

    Science.gov (United States)

    Yokode, Masataka; Shiomi, Hideyuki; Itai, Ryosuke; Mikami, Sakae; Yamashita, Yukimasa; Nakano, Ryota; Ezaki, Takeshi; Masuda, Atsuhiro; Zen, Yoh

    2018-01-01

    A referring hospital diagnosed a 57-year-old man with a pancreatic head mass. The initial endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) was inconclusive because of the small sample size. Endoscopic ultrasonography elastography (EUS-EG) and contrast-enhanced harmonic endoscopic ultrasonography (CE-EUS), conducted at our institute, raised the possibility of mass-forming pancreatitis or autoimmune pancreatitis (AIP). A repeat EUS-FNA revealed inflammatory changes, including a neutrophilic duct injury suggestive of type 2 AIP. The pancreatic lesion responded well to the steroid therapy. The present case suggests that EUS-EG and CE-EUS may be useful for diagnostic exclusion of pancreatic cancers, and the combined use of EUS-EG and CE-EUS, with EUS-FNA, may help characterize inflammatory pancreatic lesions.

  16. Impact of Endoscopic Ultrasonography on 18F-FDG-PET/CT Upfront Towards Patient Specific Esophageal Cancer Treatment.

    Science.gov (United States)

    Hulshoff, J B; Mul, V E M; de Boer, H E M; Noordzij, W; Korteweg, T; van Dullemen, H M; Nagengast, W B; Oppedijk, V; Pierie, J P E N; Plukker, John Th M

    2017-07-01

    In patients with potentially resectable esophageal cancer (EC), the value of endoscopic ultrasonography (EUS) after fluorine-18 labeled fluorodeoxyglucose positron emission tomography with computed tomography ( 18 F-FDG-PET/CT) is questionable. Retrospectively, we assessed the impact of EUS after PET/CT on the given treatment in EC patients. During the period 2009-2015, 318 EC patients were staged as T1-4aN0-3M0 with hybrid 18 F-FDG-PET/CT or 18 F-FDG-PET with CT and EUS if applicable in a nonspecific order. We determined the impact of EUS on the given treatment in 279 patients who also were staged with EUS. EUS had clinical consequences if it changed curability, extent of radiation fields or lymph node resection (AJCC stations 2-5), and when the performed fine-needle aspiration (FNA) provided conclusive information of suspicious lymph node. EUS had an impact in 80 (28.7%) patients; it changed the radiation field in 63 (22.6%), curability in 5 (1.8%), lymphadenectomy in 48 (17.2%), and FNA was additional in 21 (7.5%). In patients treated with nCRT (n = 194), EUS influenced treatment in 53 (27.3%) patients; in 38 (19.6%) the radiation field changed, in 3 (1.5%) the curability, in 35 (18.0%) the lymphadenectomy, and in 17 (8.8%) FNA was additional. EUS influenced both the extent of radiation field and nodal resection in 31 (16.0%) nCRT patients. EUS had an impact on the given treatment in approximately 29%. In most patients, the magnitude of EUS found expression in the extent of radiotherapy target volume delineation to upper/high mediastinal lymph nodes.

  17. Comparison of helical computed tomography and ultrasonography in diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Nafees, M.; Abbas, G.; Sarwar, S.

    2010-01-01

    The objective of study is to compare the diagnostic accuracy of helical computed tomography and ultrasonography in acute appendicitis using histopathology as gold standard. Thirty cases of clinically suspected acute appendicitis were included in the study selected on non probability convenience sampling technique. Computed tomography and graded compression ultrasonography of right lower quadrant of abdomen were conducted and results compared with histopathological findings. Amongst 30 patients who underwent computed tomography and graded compression ultrasonography examinations of right lower quadrant for diagnosis of acute appendicitis, on computed tomography 19 were diagnosed with acute appendicitis, 10 were diagnosed as not having the disease and 01 patient diagnosed as not having appendicitis on computed tomography did not improve clinically, was operated upon and histopathology proved it as acute appendicitis. While on graded compression ultrasonography 15 were diagnosed with acute appendicitis, 11 were diagnosed as not having the disease and 04 patients diagnosed as not having appendicitis on ultrasonography, did not improve clinically, were operated upon and histopathology proved it as acute appendicitis. This showed that CT scan has sensitivity of 95%, specificity 100%, positive predictive value 100%, negative predictive value 90.91% and overall accuracy of 96.67% while ultrasonography has sensitivity of 78.9%, specificity 100%, positive predictive value 100%, negative predictive value 73.33% and overall accuracy of 86.67%. We concluded that Helical computed tomography is highly accurate in diagnosing acute appendicitis as compared to ultrasonography and it helps to reduce negative appendectomy rate. (author)

  18. Ultrasonography and computed tomography in diffuse liver disease with cholestasis

    International Nuclear Information System (INIS)

    Partanen, K.; Pikkarainen, P.; Pasanen, P.; Alhava, E.; Soimakallio, S.; Kuopio Univ. Central Hospital; Kuopio Univ. Central Hospital

    1990-01-01

    Ultrasonography (US) and computed tomography (CT) were performed on respectively 67 and 42 (altogether 72) patients, for the assessment of intrahepatic cholestasis. The diagnostic ability to differentiate between malignant (17 patients) and benign (55 patients) liver disease was analyzed. Coarse echogenicity of the liver led to inconclusive results in differentiating between cirrhosis (2 out of 29 patients) and malignant infiltration (4 out of 15 patients) by US. Other benign liver diseases in 23 patients, including acute hepatitis, chronic active hepatitis, fatty liver, and liver congestion, were correctly interpreted as benign. CT correctly disclosed malignant liver disease in all cases. A false positive diagnosis of malignancy was encountered in 4 (out of 17) patients with decompensated hepatic cirrhosis because of non-homogeneous expansive areas on CT in 3 cases. The true cause was in 2 patients non-uniform fatty infiltration, and in one patient with acute hepatitis A, small hypodense lesions. Among cholestatic patients, decompensated cirrhosis and malignant liver infiltration could not always be differentiated on US or CT. (orig.)

  19. Comparison of endoscopic ultrasonography and computed tomography in detecting mediastinal and hilar lymph nodes from bronchogenic carcinoma

    International Nuclear Information System (INIS)

    Imamura, Masahiro; Murata, Takashi; Yoshida, Masayuki

    1990-01-01

    We investigated and compared the ability of CT and endoscopic ultrasonography by radial scanning (EUS) to diagnose metasasis of lung cancer to the mediastinum and hilar lymph nodes in 27 patients undergoing resection of primary lung cancer and 6 autopsy cases. We also determined the relationship between the presence or absence of metastasis and the size of each lymph node based on the lymph node size measured at the time of resection and its histopathological findings, and we then set up a standard value that was the most accurate in evaluating the presence or absence of metastasis using a receiver operating characteristics (ROC) curve. When lymph node sizes appearing as images were compared with their actual sizes measured on resected specimens before formalin fixation, the short axis measured by either method was found to generally agree with the actual values, while the long axis was slightly smaller than the actual values, although EUS gave more accurate values. When the ability to diagnose metastasis was compared between CT and EUS using the standard value obtained from the ROC curve (a more than 8 mm short axis was defined as positive for metastasis), there were no differences in the ability to delineate the entire area of the mediastinum, including hilar lymph nodes. With respect to individual sites, although there was some difficulty delineating some regions in the mediastinum (pretracheal lymph node) with EUS, more lymph nodes in the mediastinum that were delineated by EUS histopathologically had metastatic lesions than those delineated by CT. However, both methods often failed to delineate hilar lymph nodes, with no difference between the two methods. (author)

  20. Evaluation of abdominal trauma by computed tomography and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Kim, Sang Jin; Lee, Jong Tae; Yoo, Hyung Sik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1986-06-15

    Out of 75 patients who were admitted to our hospital because of abdominal trauma and were undergone the procedures such as ultrasonography and/or CT scan within 24 hours of abdominal trauma due to suspected abdominal organ injury. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. 1. In the abdominal organ injury, solid organ injury consists of 8 cases of spleen laceration, 1 of splenic subcapsular hematoma, 7 of hepatic laceration, 7 of pancreas laceration, 3 of renal laceration, and 3 of subcapsular hematoma of kidney. 2. In addition, there were 7 bowel and/or mesenteric laceration, 2 diaphragmatic hernia, and 1 urethral rupture. 3. 2 cases of retroperitoneal hematoma and 1 case in which hemo peritoneum occurred without abdominal organ injury were confirmed by follow-up CT or ultrasonography. 4. In all of the 4 patients with multiple organ injury, pancreatic laceration was associated. 5. In abdominal trauma patients, ultrasonography or CT can be used to survey rapidly the entire abdomen for possible associated injury, and be of great help to clinicians in identifying the patients who need immediate surgery or in minimizing the incidence of unnecessary emergency abdominal exploration.

  1. Evaluation of abdominal trauma by computed tomography and ultrasonography

    International Nuclear Information System (INIS)

    Lee, Do Yun; Kim, Sang Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1986-01-01

    Out of 75 patients who were admitted to our hospital because of abdominal trauma and were undergone the procedures such as ultrasonography and/or CT scan within 24 hours of abdominal trauma due to suspected abdominal organ injury. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. 1. In the abdominal organ injury, solid organ injury consists of 8 cases of spleen laceration, 1 of splenic subcapsular hematoma, 7 of hepatic laceration, 7 of pancreas laceration, 3 of renal laceration, and 3 of subcapsular hematoma of kidney. 2. In addition, there were 7 bowel and/or mesenteric laceration, 2 diaphragmatic hernia, and 1 urethral rupture. 3. 2 cases of retroperitoneal hematoma and 1 case in which hemo peritoneum occurred without abdominal organ injury were confirmed by follow-up CT or ultrasonography. 4. In all of the 4 patients with multiple organ injury, pancreatic laceration was associated. 5. In abdominal trauma patients, ultrasonography or CT can be used to survey rapidly the entire abdomen for possible associated injury, and be of great help to clinicians in identifying the patients who need immediate surgery or in minimizing the incidence of unnecessary emergency abdominal exploration.

  2. Cost-effectiveness of endoscopic ultrasonography, magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography in patients suspected of pancreaticobiliary disease

    DEFF Research Database (Denmark)

    Ainsworth, A P; Rafaelsen, S R; Wamberg, P A

    2004-01-01

    BACKGROUND: It is not known whether initial endoscopic ultrasonography (EUS) or magnetic resonance cholangiopancreatography (MRCP) is more cost effective than endoscopic retrograde cholangiopancreatography (ERCP). METHODS: A cost-effectiveness analysis of EUS, MRCP and ERCP was performed on 163...

  3. Evaluation of the hip joint by computed tomography and ultrasonography

    International Nuclear Information System (INIS)

    Anda, S.

    1991-04-01

    In patients with dysplastic hips the acetabular angles and femoral anteversion were determined in a CT investigation. Comparative investigations of femoral anteversion were made by ultrasonography and biomedical radiography. The investigations are described and the general conclusions discussed. 205 refs., 15 figs., 10 tabs

  4. Computed tomography, ultrasonography, and endoscopic retrograde cholangiopancreatography in the diagnosis of pancreatic disease

    International Nuclear Information System (INIS)

    Foley, W.D.; Stewart, E.T.; Lawson, T.L.; Maher, L.; Unger, G.F.; Geenan, J.; Loguidice, J.

    1980-01-01

    A prospective study was performed comparing the sensitivity of computed tomography, ultrasonography, and endoscopic retrograde cholangiopancreatography (ERCP) in the diagnosis of pancreatic disease. Forty patients with suspected pancreatic carcinoma, acute recurrent or chronic pancreatitis, and/or jaundice were studied. CT was the most sensitive study in evaluation of pancreatitis. ERCP was most accurate in evaluation of pancreatic malignancy. Ultrasonography was the least sensitive method in detecting pancreatic disease and dilatation of the extrahepatic biliary ducts. (orig.) [de

  5. Ultrasonography, computed tomography, and cholescintigraphy in suspected obstructive jaundice--a prospective comparative study

    DEFF Research Database (Denmark)

    Matzen, P; Malchow-Møller, A; Brun, B

    1983-01-01

    In order to compare their capacity to visualize the bile ducts, ultrasonography, computed tomography, and cholescintigraphy were performed in 56 consecutive jaundiced patients in whom extrahepatic cholestasis was clinically suspected. The predictions as to the patency of the large bill ducts were...

  6. Diagnosis and treatment of postoperative intraperitoneal abscess using ultrasonography and abdominal computed tomography

    International Nuclear Information System (INIS)

    Kamachi, Hisashi; Kumashiro, Ryunosuke; Maekawa, Takafumi; Saku, Haruhisa; Naitoh, Hideaki; Inutsuka, Sadamitsu; Higashi, Yoshitaka

    1988-01-01

    Ultrasonography and/or abdominal computed tomography revealed 9 patients with subphrenic abscesses derived from gastrointestinal surgery. Out of them 4 cases underwent conservative treatment is chosen with aggresive chemotherapy, but 5 were re-surgically treated including drainage of the intraperitonial abscess or repairing the leakage of the anastomosis. On the conservative treatment for the intraperitonial abscess, frequent monitoring with ultrasonography was very conventional for successful treatment. However, in the cases with severe leukocytosis, leakage of anastomosis or recurrent intraperitonial abscess, resurgical treatment will be required. Thus the monitoring with ultrasonography is quite usefull not only in the drainaging of the intraperitonial abscess, but also in the judgement of treatment whether conservetive or re-operative. (author)

  7. Evaluation of transurethral ultrasonography and computed tomography in the staging of bladder tumors

    International Nuclear Information System (INIS)

    Yamakawa, Kensuke; Hoshina, Akira; Tochigi, Hiromi; Kawamura, Juichi

    1987-01-01

    A definitive pathologic diagnosis was made in 47 patients with bladder tumors from cystectomy specimens or by surgical exploration. The tumor was staged in 35 cases by transurethral ultrasonography and in 39 cases by computed tomography. We obtained the following results : the accuracy was 83 % using transurethral sonography, 77 % using computed tomography. Although transurethral ultrasonography is more advantageous than computed tomography in the low stage in regard to accuracy, computed tomography is excellent method to obtain information about the tumor invasion and/or metastases. Of 25 cases combind with computed tomography and transurethral sonography. tumors were correctly staged by both methods in 18 cases (72 %). Histopathological stage was consistent with neither ultrasonographic stage nor computed tomographic stage in 2 cases, and any of these tumors was correctly staged by either of these methods. Although transurethral ultrasonography and computed tomography improve the clinical stage of the bladder tumors separately, some limitations and problems was recognized on using together with these methods for staging the bladder tumors. (author)

  8. New endoscopic ultrasonography techniques for pancreticobiliary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kamata, Ken; Kitano, Masayuki; Omoto, Shunsuke; Kadosaka, Kumpei; Miyata, Takeshi; Minaga, Kosuke; Yamao, Kentaro; Imai, Hajime; Kudo, Masatoshii [Dept. of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka (Japan)

    2016-07-15

    Endoscopic ultrasonography (EUS) is widely used to evaluate pancreaticobiliary diseases, especially pancreatic masses. EUS has a good ability to detect pancreatic masses, but it is not sufficient for the differential diagnosis of various types of lesions. In order to address the limitations of EUS, new techniques have been developed to improve the characterization of the lesions detected by EUS. EUS-guided fine needle aspiration (EUS-FNA) has been used for diagnosing pancreatic tumors. In order to improve the histological diagnostic yield, a EUS-FNA needle with a core trap has recently been developed. Contrast-enhanced harmonic EUS is a new imaging modality that uses an ultrasonographic contrast agent to visualize blood flow in fine vessels. This technique is useful in the diagnosis of pancreatic solid lesions and in confirming the presence of vascularity in mural nodules for cystic lesions. EUS elastography analyzes several different variables to measure tissue elasticity, color patterns, and strain ratio, using analytical techniques such as hue-histogram analysis, and artificial neural networks, which are useful for the diagnosis of chronic pancreatitis and pancreatic cancer.

  9. Diagnostic value of liver scintigraphy, computed tomography and ultrasonography of fatal hepatitis

    International Nuclear Information System (INIS)

    Komori, Hideshi; Hirasa, Masahiro; Ibuki, Yasuyoshi

    1983-01-01

    The purpose of this study was investigate the diagnostic value of liver scintigraphy, computed tomography (CT) and ultrasonography in acute hepatic failure, subacute hepatitis and acute hepatitis. By scintigraphy low uptake in the liver and high uptake in the spleen and bone marrow were observed in hepatic failure. However, uneven liver edge and heterogenous RI destribution were not corresponded to massive necrosis. In fulminant hepatitis, liver size and other findings were variable in patient by patient. But in subacute hepatitis, the findings were typical. The finding of left lobe swelling was observed in a half of patients with acute hepatic failure based on chronic hepatitis. Localized low density area by the CT was detected in most of the cases of subacute hepatitis, and acute hepatitis with submassive hepatic necrosis. But in fulminant hepatitis, that was rare. In these cases, irregular and strong lesion was also obsurved by ultrasonography. These findings by the CT and ultrasonography were corresponded to massive necrosis histrogically ultrasonography revealed narrowing of hepatic vein in fatal hepatitis. Localized low density area by the CT in subacute hepatitis was shown surrounding hepatic vein. We conclude that development of massine hepatic necrosis concern to secondary hepatic ischemia. (author)

  10. Incidence of bacteremia in cirrhotic patients undergoing upper endoscopic ultrasonography.

    Science.gov (United States)

    Fernández-Esparrach, Gloria; Sendino, Oriol; Araujo, Isis; Pellisé, Maria; Almela, Manel; González-Suárez, Begoña; López-Cerón, María; Córdova, Henry; Sanabria, Erwin; Uchima, Hugo; Llach, Josep; Ginès, Àngels

    2014-01-01

    The incidence of bacteremia after endoscopic ultrasonography (EUS) or EUS-guided fine-needle aspiration (EUS-FNA) is between 0% and 4%, but there are no data on this topic in cirrhotic patients. To prospectively assess the incidence of bacteremia in cirrhotic patients undergoing EUS and EUS-FNA. We enrolled 41 cirrhotic patients. Of these, 16 (39%) also underwent EUS-FNA. Blood cultures were obtained before and at 5 and 30 min after the procedure. When EUS-FNA was used, an extra blood culture was obtained after the conclusion of radial EUS and before the introduction of the sectorial echoendoscope. All patients were clinically followed up for 7 days for signs of infection. Blood cultures were positive in 16 patients. In 10 patients, blood cultures grew coagulase-negative Staphylococcus, Corynebacterium species, Propionibacterium species or Acinetobacterium Lwoffii, which were considered contaminants (contamination rate 9.8%, 95% CI: 5.7-16%). The remaining 6 patients had true positive blood cultures and were considered to have had true bacteremia (15%, 95% CI: 4-26%). Blood cultures were positive after diagnostic EUS in five patients but were positive after EUS-FNA in only one patient. Thus, the frequency of bacteremia after EUS and EUS-FNA was 12% and 6%, respectively (95% CI: 2-22% and 0.2-30%, respectively). Only one of the patients who developed bacteremia after EUS had a self-limiting fever with no other signs of infection. Asymptomatic Gram-positive bacteremia developed in cirrhotic patients after EUS and EUS-FNA at a rate higher than in non-cirrhotic patients. However, this finding was not associated with any clinically significant infections. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.

  11. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography. Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-02-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt.

  12. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-01-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt. (author)

  13. Hepatic hemangiomas as diagnosed by ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    Sachse, M.

    1987-01-01

    A total of 62 cases where the clinical diagnosis of hepatic hemangioma had been established during the period between 1981 and 1983 on the basis of computed tomography and sonography were subjected to retrospective analysis with the aim of evaluating the diagnostic reliability of these two methods. In 29 patients a typical distribution pattern of the contrast medium gave irrefutable evidence of the disease. Hemangiomas were predicted from the results of computed tomography for a further 5 patients with less revealing distribution patterns, although in 4 among these the preliminary diagnosis of hemangioma was disproved by additional diagnostic procedures (scintigraphy, laparoscopy, surgery and biopsy). Out of 16 patients, in which the hemangiomas were diagnosed from the typical patterns created by the contrast medium on the CT scans, 11 showed sonographic findings to confirm the presence of such tumours. This retrospective analysis showed that a correct and positive diagnosis could be established in no more than 7 patients on the basis of sonography alone, while 6 such diagnoses were definitely proven to be false-positive. As regards diagnostic accuracy, sonography clearly compares unfavourably with computed tomography. It may offer some advantages inasmuch as it requires no radiation exposure, is non-invasive and, last not least, less costly. (ECB) [de

  14. Endoscopic ultrasonography-guided rendezvous technique.

    Science.gov (United States)

    Tsuchiya, Takayoshi; Itoi, Takao; Sofuni, Atsushi; Tonozuka, Ryosuke; Mukai, Shuntaro

    2016-04-01

    Endoscopic retrograde cholangiopancreatography (ERCP) requires deep biliary cannulation. When deep biliary cannulation is failed, the endoscopic ultrasonography rendezvous technique (EUS-RV) is a useful salvage method. From the previous 15 articles that included 382 EUS-RV cases, the overall success rate of EUS-RV is 81 % with a complication rate of 10 %. In EUS-RV, the bile duct is punctured under EUS guidance and a guidewire is advanced into the duodenum via the papilla. The EUS scope is then switched to a duodenoscope and inserted into the bile duct over the guidewire exiting the papilla, or the guidewire is grasped with forceps and passed through the working channel; the catheter can then be inserted through the papilla over the wire. There are three puncture routes for EUS-RV: transgastric puncture of the intrahepatic bile duct (IHBD), transduodenal puncture of the extrahepatic bile duct (EHBD) via the proximal duodenum (D1), and transduodenal puncture of the EHBD via the second portion of the duodenum (D2). The puncture route for each patient should be selected based on the patient condition. GW selection for EUS-RV is critical, a hydrophilic GW is useful for this procedure. Although EUS-RV is now performed relatively routinely in a few high-volume centers, procedure standardization and the development of exclusive devices for EUS-RV are still underway. The development of exclusive devices for EUS-RV and prospective comparative studies with other salvage methods are needed to truly evaluate the procedure's usefulness and safety.

  15. Clinical impact of endoscopic ultrasonography at a county hospital

    DEFF Research Database (Denmark)

    Ainsworth, A P; Mortensen, M B; Durup, J

    2002-01-01

    BACKGROUND AND STUDY AIMS: Although endoscopic ultrasonography (EUS) is a well-described examination method, there have been few reports concerning its clinical impact. The aim of this study was to describe EUS as it is performed at a county hospital, with an emphasis on the indications...... and clinical outcome. PATIENTS AND METHODS: Patients examined using EUS between December 1997 and November 2000 were recorded prospectively. Follow-up was conducted by examining each patient's medical records at least 3 months after the investigation. The EUS findings were compared with the patient's final...... management strategy in 80 patients (24 %). CONCLUSIONS: EUS has a high level of accuracy and a substantial clinical impact when performed in an unselected population. The estimated numbers of investigations needed appear to justify setting up an EUS center at institutions with a catchment population of 350...

  16. Comparison of ultrasonography and computed tomography in the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Cura, J. L. del; Oleaga, L.; Grande, D.; Farina, M. A.; Isusi, M.

    2001-01-01

    The compare the efficacy of ultrasonography and computed tomography (CT) in cases of suspected appendicitis. To study to what extent age, sex and habits of the patients, as well as the clinical context, influence the diagnostic yield of these two technique. Over a one-year period, 152 patients underwent ultrasonography and CT because of the clinical suspicion of appendicitis. The studies were carried out independently, and the results of each in terms of the presence or absence of appendicitis were unknown to the specialists performing the other. The final diagnoses were established by surgical treatment or clinical follow-up. The sensitivity of CT for the diagnosis of appendicitis was 82%, the specificity was 95%, the positive predictive value was 93%, the negative predictive value was 87% and the reliability was 90%. Ultrasonography has a sensitivity of 83%, a specificity of 97%, a positive predictive value of 95%, a negative predictive value of 88% and a reliability of 91%. Ultrasound was more efficient in patients in which there was a high clinical suspicion and in children, while the results with CT were better in patients in which the clinical diagnosis was less clear. The incidence of false negatives and positives was higher with ultrasound, while CT was more frequently able to identify a normal appendix. Sex and habits had no influence on the respective efficacies, although the performance of ultrasound was simplified in thin patients and that of CT in obese individuals. Ultrasonography and CT are highly reliable in cases of suspected appendicitis, especially when this diagnosis is conformed. Ultrasound is recommended as the technique of choice in children and in patients in which the clinical suspicion is strong. The yield of CT is somewhat greater when the clinical signs and symptoms are less clear. However, the efficacy of both techniques ultimately depends on the expertise of the specialist who interprets them. (Author) 62 refs

  17. Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models

    Directory of Open Access Journals (Sweden)

    Anderson Chun On Tsang

    2015-04-01

    Full Text Available Purpose: The aim of this study was to validate a computational fluid dynamics (CFD simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents.

  18. Comparative study of Graves' ophthalmopathy by ultrasonography, computed tomography, and fish bioassay

    International Nuclear Information System (INIS)

    Mann, K.; Schoener, W.; Juengst, D.; Karl, H.J.; Maier-Hauff, K.; Rothe, R.

    1979-01-01

    In 35 patients with Graves' ophthalmopathy (GO) thyroid function was tested by T 3 -RIA, T 4 -RIA, TBI, TRH-test, thyroid scanning, and determination of thyroid autoantibodies. Additional ultrasonography (A-scan), computed tomography (CT) of the orbit, and the determination of an exophthalmogenic serum activity in fish bioassay was performed. Typical alterations for GO were observed in 26 cases with ultrasonography. CT showed an enlargement of medial and/or lateral rectus muscles in 24 of 33 patients, and in 17 cases a region of high density in the apex of the muscle cone. The density of retrobulbar fat after i.v. injection of contrast medium did not differ significantly from that observed in normal men. Characteristic signs of GO were not detected in only 2 cases using both methods together. Exophthalmogenic serum activity was found in the IgG fraction of serum protein. The incidence rate was high (69%), but for diagnostic purpose the fish bioassay cannot be recommended. (orig.) 891 AJ/orig. 892 BRE [de

  19. Comparative evaluation of ultrasonography, computed tomography and magnetic resonance imaging in the follow-up of Budd-Chiari syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Legmann, P; Levesque, M; De, Broucker F; F,; Hay, J M; Maillard, J N

    1988-01-01

    A comparative evaluation of ultrasonography, computed tomography and MRI in 8 patients operated for Budd-Chiari syndrome is reported. The results obtained, evaluated separately for each technique and then compared between each other and with the data of superior coelio-mesenteric angiography and inferior cavography, show that the MRI data is very clearly superior to the data obtained by ultrasonography and computed tomography. MRI allows simultaneous assessment of the hepatic parenchyma, evaluation of portal hypertension and the porto-caval anastomosis, which are all essential elements in the follow-up Budd-Chiari syndrome. However, in the light of the literature, the authors stress that ultrasonography associated with pulsed Doppler also ensures satisfactory vascular and parenchymal assessment of this disease in the majority of cases.

  20. Comparative evaluation of ultrasonography, computed tomography and magnetic resonance imaging in the follow-up of Budd-Chiari syndrome

    International Nuclear Information System (INIS)

    Legmann, P.; Levesque, M.; Broucker, F. de; Hay, J.M.; Maillard, J.N.

    1989-01-01

    The authors report a comparative evaluation of ultrasonography, computed tomography and MRI in 8 patients operated for Budd-Chiari syndrome. The results obtained, evaluated separately for each technique and then compared between each other and with the data of superior coelio-mesenteric angiography and inferior cavography, showed that MRI data is very clearly superior to the data obtained by ultrasonography and computed tomography. MRI allows simultaneous assessment of the hepatic parenchyma, and evaluation of portal hypertension and the porto-caval anastomosis, which are all essential elements in the follow-up Budd-Chiari syndrome. However, in the light of the literature, the authors stress that ultrasonography associated with pulsed Doppler also ensures satisfactory vascular and parenchymal assessment of this disease in the majority of cases [fr

  1. Accuracy of endoscopic ultrasonography for diagnosing ulcerative early gastric cancers

    Science.gov (United States)

    Park, Jin-Seok; Kim, Hyungkil; Bang, Byongwook; Kwon, Kyesook; Shin, Youngwoon

    2016-01-01

    Abstract Although endoscopic ultrasonography (EUS) is the first-choice imaging modality for predicting the invasion depth of early gastric cancer (EGC), the prediction accuracy of EUS is significantly decreased when EGC is combined with ulceration. The aim of present study was to compare the accuracy of EUS and conventional endoscopy (CE) for determining the depth of EGC. In addition, the various clinic-pathologic factors affecting the diagnostic accuracy of EUS, with a particular focus on endoscopic ulcer shapes, were evaluated. We retrospectively reviewed data from 236 consecutive patients with ulcerative EGC. All patients underwent EUS for estimating tumor invasion depth, followed by either curative surgery or endoscopic treatment. The diagnostic accuracy of EUS and CE was evaluated by comparing the final histologic result of resected specimen. The correlation between accuracy of EUS and characteristics of EGC (tumor size, histology, location in stomach, tumor invasion depth, and endoscopic ulcer shapes) was analyzed. Endoscopic ulcer shapes were classified into 3 groups: definite ulcer, superficial ulcer, and ill-defined ulcer. The overall accuracy of EUS and CE for predicting the invasion depth in ulcerative EGC was 68.6% and 55.5%, respectively. Of the 236 patients, 36 patients were classified as definite ulcers, 98 were superficial ulcers, and 102 were ill-defined ulcers, In univariate analysis, EUS accuracy was associated with invasion depth (P = 0.023), tumor size (P = 0.034), and endoscopic ulcer shapes (P = 0.001). In multivariate analysis, there is a significant association between superficial ulcer in CE and EUS accuracy (odds ratio: 2.977; 95% confidence interval: 1.255–7.064; P = 0.013). The accuracy of EUS for determining tumor invasion depth in ulcerative EGC was superior to that of CE. In addition, ulcer shape was an important factor that affected EUS accuracy. PMID:27472672

  2. Recurrent pyogenic cholangitis in Asian immigrants: use of ultrasonography, computed tomography, and cholangiography

    International Nuclear Information System (INIS)

    Federle, M.P.; Cello, J.P.; Laing, F.C.; Jeffery, R.B. Jr.

    1982-01-01

    Five cases of recurrent pyogenic cholangitis (RPC) were studied by ultrasonography, computed tomography (CT), and cholangiography. All patients were recent immigrants from the Orient or Indonesia and had had recurrent attacks of cholangitis for many years. The bile was infected by E. coli and the biliary ducts were dilated; in addition, extrahepatic bile-pigment calculi we represent in all 5 and intrahepatic calculi in 4. Abdominal ultrasound usually failed to demonstrate duct calculi and extrahepatic dilatation due to the soft, mud-like consistency of the stones. CT was successful in showing the calculi and the full extent of dilatation. The authors conclude that preoperative diagnosis of RPC is best achieved by awareness of the characteristic clinical presentation and the findings on abdominal CT. Preoperative cholangiography provides excellent detail, but poses the danger of biliary sepsis requiring antibiotics

  3. Clinical application of endoscopic ultrasonography for esophageal achalasia.

    Science.gov (United States)

    Minami, Hitomi; Inoue, Haruhiro; Isomoto, Hajime; Urabe, Shigetoshi; Nakao, Kazuhiko

    2015-04-01

    Endoscopic ultrasonography (EUS) has been widely used for evaluating the nature of diseases of various organs. The possibility of applying EUS for esophageal motility diseases has not been well discussed despite its versatility. At present, peroral endoscopic myotomy (POEM) for esophageal achalasia and related diseases has brought new attention to esophageal diseases because POEM provides a more direct approach to the inner structures of the esophageal wall. In the present study, we discuss the clinical utility of EUS in evaluating and treating esophageal motility diseases such as esophageal achalasia and related diseases. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  4. Endoscopic Ultrasonography-Guided Techniques for Accessing and Draining the Biliary System and the Pancreatic Duct.

    Science.gov (United States)

    Rimbaş, Mihai; Larghi, Alberto

    2017-10-01

    When endoscopic retrograde cholangiopancreatography (ERCP) fails to decompress the biliary system or the pancreatic duct, endoscopic ultrasonography (EUS)-guided biliary or pancreatic access and drainage can be used. Data show a high success rate and acceptable adverse event rate for EUS-guided biliary drainage. The outcomes of EUS-guided biliary drainage seem equivalent to percutaneous drainage and ERCP, whereas only retrospective studies are available for pancreatic duct drainage. In this article, revision of the technical and clinical status and the current evidence of interventional EUS-guided biliary and pancreatic duct access and drainage are presented. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Ultrasonography and computed tomography in the study of orbital tumors and pseudo-tumoral lesions

    International Nuclear Information System (INIS)

    Marins, J.L.C.; Pereira, R.M.; Prando, A.; Selos Moreira, A.R. de

    1987-01-01

    The computerized tomography and the ultrasonography in the ocular and orbital patologies were considered as complementary each other. the ultrasonography method as choice for the detection of the eye lesions in the adult, particularly of vascular origin and in the follow-up of inflammatory and pseudo-tumoral lesions was chosen. (L.M.J.) [pt

  6. An experimental study on prediction of gallstone composition by ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    Lee, Jong Beum; Chung, Sae Yul; Kim, Kun Sang; Lee, Yong Chul; Han, Man Chung; Kim, Jin Kyu

    1992-01-01

    Prediction of chemical composition of gallstones is a prerequisite in contemplating the chemical dissolution or extracorporeal shock wave lithotripsy of gallstones. The author retrospectively analysed the correlation between quantitative chemical composition of gallstones and their ultrasonographic and computed tomographic findings. The ultrasonography(US) and computed tomography(CT) of 100 consecutive stones obtained from 100 patients were performed under the in vitro condition. Their US and CT findings were grouped with certain pattern and each group was compared with the chemical composition of the stones. Stones with entirely discernible circumference and homogeneous internal echo on US had high bilirubin and low cholesterol content. Acoustic shadows were frequently absent with those stones. Stones with variable internal echo on US had relatively high cholesterol content but their distribution range were wide. There was no correlationship between the cholesterol content and the CT No. of the gallstones. There was positive correlationship between the calcium content and the CT No. of gallstones. The near totally calcified gallstones had very low cholesterol and high residue content. There was no relationship between the calcification type and the ultrasonographic pattern. In conclusion, those stones with entirely discernible circumference and homogeneous internal echo on US were pigment stones. On the contrary, stones with variable internal echo had relatively high cholesterol content. CT could predict the calcium content with CT No., but could not predict the cholesterol content

  7. A new method for evaluating gastric ulcer healing by endoscopic ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Niwa, Y.; Nakazawa, S.; Tsukamoto, Y. (and others) (Ichinomiya Municipal Hospital (JP))

    1991-01-01

    The authors observed the quantitative estimation of the transmural changes associated with gastric ulcer healing by using endoscopic ultrasonography (EUS). It was possible to diagnose the depth of ulcer by EUS. 48 patients were divided into three treatment groups. Group A (n=16) was treated with 800 mg cimetidine daily, group B (n=22) with 20 mg omeprazole daily, and group C (n=10) with 400 mg cimetidine + 300 mg gefarnate daily. EUS was performed before and after 2, 4 and 8 weeks of treatment. The groups were compared from the viewpoints of endoscopic findings and contraction rate of the length and the cross-sectional area of the ulcer in EUS pictures. The best healing of both the endoscopic and EUS findings was seen in group B. By estimating the changes inside the ulcer, EUS may provide useful information for choice of anti-ulcer agents. 21 refs., 5 figs., 3 tabs.

  8. Graded compression ultrasonography and computed tomography in acute colonic diverticulitis: Meta-analysis of test accuracy

    International Nuclear Information System (INIS)

    Lameris, Wytze; Randen, Adrienne van; Bipat, Shandra; Stoker, Jaap; Bossuyt, Patrick M.M.; Boermeester, Marja A.

    2008-01-01

    The purpose was to investigate the diagnostic accuracy of graded compression ultrasonography (US) and computed tomography (CT) in diagnosing acute colonic diverticulitis (ACD) in suspected patients. We performed a systematic review and meta-analysis of the accuracy of CT and US in diagnosing ACD. Study quality was assessed with the QUADAS tool. Summary estimates of sensitivity and specificity were calculated using a bivariate random effects model. Six US studies evaluated 630 patients, and eight CT studies evaluated 684 patients. Overall, their quality was moderate. We did not identify meaningful sources of heterogeneity in the study results. Summary sensitivity estimates were 92% (95% CI: 80%-97%) for US versus 94% (95%CI: 87%-97%) for CT (p = 0.65). Summary specificity estimates were 90% (95%CI: 82%-95%) for US versus 99% (95%CI: 90%-100%) for CT (p = 0.07). For the identification of alternative diseases sensitivity ranged between 33% and 78% for US and between 50% and 100% for CT. The currently best available evidence shows no statistically significant difference in accuracy of US and CT in diagnosing ACD. Therefore, both US and CT can be used as initial diagnostic tool until new evidence is brought forward. However, CT is more likely to identify alternative diseases. (orig.)

  9. Visualization of haemophilic arthropathy in F8(-/-) rats by ultrasonography and micro-computed tomography

    DEFF Research Database (Denmark)

    Christensen, K R; Roepstorff, K; Petersen, M

    2017-01-01

    opportunities. Recently, a F8(-/-) rat model of HA was developed. The size of the rat allows for convenient and high resolution imaging of the joints, which could enable in vivo studies of HA development. AIM: To determine whether HA in the F8(-/-) rat can be visualized using ultrasonography (US) and micro......-computed tomography (μCT). METHODS: Sixty F8(-/-) and 20 wild-type rats were subjected to a single or two induced knee bleeds. F8(-/-) rats were treated with either recombinant human FVIII (rhFVIII) or vehicle before the induction of knee bleeds. Haemophilic arthropathy was visualized using in vivo US and ex vivo μCT......, and the observations correlated with histological evaluation. RESULTS: US and μCT detected pathologies in the knee related to HA. There was a strong correlation between disease severity determined by μCT and histopathology. rhFVIII treatment reduced the pathology identified with both imaging techniques. CONCLUSION: US...

  10. EUS – Fine- Needle Aspiration Biopsy (FNAB in the Diagnosis of Pancreatic Adenocarcinoma: A Review

    Directory of Open Access Journals (Sweden)

    Kalogeraki Alexandra

    2016-03-01

    Full Text Available Solid masses of the pancreas represent a variety of benign and malignant neoplasms of the exocrine and endocrine tissues of the pancreas. A tissue diagnosis is often required to direct therapy in the face of uncertain diagnosis or if the patient is not a surgical candidate either due to advanced disease or comorbidities. Endoscopic ultrasound (EUS is a relatively new technology that employs endoscopy and high-frequency ultrasound (US. EUS involves imaging of the pancreatic head and the uncinate from the duodenum and imaging of the body and tail from the stomach. It has been shown to be a highly sensitive method for the detection of pancreatic masses. It is superior to extracorporeal US and computed tomographic (CT scans, especially when the pancreatic tumor is smaller than 2-3 cm. Although EUS is highly sensitive in detecting pancreatic solid masses, its ability to differentiate between inflammatory masses and malignant disease is limited. Endoscopic retrograde cholangiopancreatography (ERCP brushing, CT-guided biopsies, and transabdominal ultrasound (US have been the standard nonsurgical methods for obtaining a tissue diagnosis of pancreatic lesions, but a substantial false-negative rate has been reported. Transabdominal US-guided fine-needle aspiration biopsy (US-FNAB has been used for tissue diagnosis in patients with suspected pancreatic carcinoma. It has been shown to be highly specific, with no false-positive diagnoses. With the advent of curvilinear echoendoscopes, transgastric and transduodenal EUS-FNAB of the pancreas have become a reality EUS with FNAB has revolutionized the ability to diagnose and stage cancers of the gastrointestinal tract and assess the pancreas. Gastrointestinal cancers can be looked at with EUS and their depth of penetration into the intestinal wall can be determined. Any suspicious appearing lymph nodes can be biopsied using EUS/FNAB. The pancreas is another organ that is well visualized with EUS. Abnormalities

  11. The use of multi-detector computed tomography and ultrasonography for evaluation of pleural lesions

    Directory of Open Access Journals (Sweden)

    Adel Salah Bediwy

    2015-01-01

    Conclusion: MDCT is an important noninvasive imaging tool in accurate detection and characterization of pleural lesions with complementary MPR images that solve many diagnostic problems. Ultrasonography is a safer alternative but with less diagnostic value.

  12. Clinical impact of High-Definition Endoscopic Ultrasonography (EUS in a district hospital Impacto clínico de la introducción de la ultrasonografía endoscópica (USE alta en un hospital de área

    Directory of Open Access Journals (Sweden)

    E. Poves

    2010-12-01

    Full Text Available Objectives: Evaluation of the impact of EUS in clinical practice. Methods: All exploration performed during the first 18 months of implementation of the technique were analyzed. Agreement was assessed by radiographic techniques or surgical specimens in those cases allowed. Results: 277 exploration were performed. There have been only 2 complications and they were related to sedation in both cases. The demand increased gradually, reaching 70 scans per 100,000 inhabitants. Main indications were bile (34.3% and pancreatic processes. No pathology was found in 10% of cases; 29 cases had choledocholithiasis (93% confirmed and treated endoscopically. Chronic pancreatitis was diagnosed in 19 cases (only 15.78% of the cases were diagnosed by computed tomography. 32 patients with idiopathic acute pancreatitis were evaluated: 20 of them had evidence of microlithiasis (80% cholecystectomized and asymptomatic after a mean follow-up of 21.5 months, two cases of choledocholithiasis, 1 with chronic pancreatitis and 9 cases remained free of filial etiology. We performed 56 punctures: 39 samples of pancreas in 33 patients (81.1% of the samples were diagnostic; adenocarcinoma and serous cystadenoma were the most common diagnoses, 13 enlarged nodes and 4 abdominal masses. Conclusions: EUS is a growing demand technique that has low risks and leads to better decision-making in a significant number of patients with different diseases. Therefore, its inclusion in routine clinical practice must be considered.Objetivos: Evaluar el impacto de la introducción de la ecoendoscopia en la práctica clínica. Métodos: Se analizaron todas las exploraciones realizadas en los primeros 18 meses de implantación de la técnica. Se valoró la concordancia mediante técnicas radiológicas o piezas quirúrgicas en los casos en los que fue posible. Resultados: Se realizaron 277 exploraciones. Sólo se han registrado 2 complicaciones y en ambos casos fue en relación con la sedaci

  13. Quantitative contrast-enhanced harmonic EUS in differential diagnosis of focal pancreatic masses (with videos)

    DEFF Research Database (Denmark)

    Săftoiu, Adrian; Vilmann, Peter; Dietrich, Christoph F

    2015-01-01

    BACKGROUND: The role of EUS with contrast agents can be expanded through the use of time-intensity curve (TIC) analysis and computer-aided interpretation. OBJECTIVE: To validate the use of parameters derived from TIC analysis in an artificial neural network (ANN) classification model designed......-guided FNA (EUS-FNA), TIC analysis, and ANN processing. MAIN OUTCOME MEASUREMENTS: Sensitivity, specificity, positive and negative predictive values (PPV, NPV) for EUS-FNA, CEH-EUS, and the ANN. RESULTS: After excluding all of the recordings that did not meet the technical and procedural criteria, 112 cases...... rise time, mean transit time, and time to peak. For the ANN, sensitivity was 94.64%, specificity 94.44%, PPV 97.24%, and NPV 89.47%. LIMITATIONS: Only PC and CP lesions were included. CONCLUSION: Parameters obtained through TIC analysis can differentiate between PC and CP cases and can be used...

  14. Clinical impact of EUS elastography followed by contrast-enhanced EUS in patients with focal pancreatic masses and negative EUS-guided FNA

    DEFF Research Database (Denmark)

    Iordache, Sevastiţa; Costache, Mădălin Ionuţ; Popescu, Carmen Florina

    2016-01-01

    and negative cytopathology after EUS-FNA, based on previously published results and cut-offs of real-time elastographic (RTE) EUS and contrast-enhanced harmonic (CEH) EUS. MATERIAL AND METHODS: We included in the study a subgroup of 50 consecutive patients with focal pancreatic masses which underwent EUS...... malignancy, the sensitivity, specificity and accuracy of RTE-EUS were: 97.7%, 77.4%, and 84% respectively. CEH-EUS had similar results: 89.5%, 80.7%, and 84%, respectively. In 25 patients with soft/mixed appearance during elastography,sequential assessment using contrast-enhanced EUSwas performed...

  15. II Brazilian consensus statement on endoscopic ultrasonography.

    Science.gov (United States)

    Maluf-Filho, Fauze; de Oliveira, Joel Fernandez; Mendonça, Ernesto Quaresma; Carbonari, Augusto; Maciente, Bruno Antônio; Salomão, Bruno Chaves; Medrado, Bruno Frederico; Dotti, Carlos Marcelo; Lopes, César Vivian; Braga, Cláudia Utsch; M Dutra, Daniel Alencar; Retes, Felipe; Nakao, Frank; de Sousa, Giovana Biasia; de Paulo, Gustavo Andrade; Ardengh, Jose Celso; Dos Santos, Juliana Bonfim; Sampaio, Luciana Moura; Okawa, Luciano; Rossini, Lucio; de Brito Cardoso, Manoel Carlos; Ribeiro Camunha, Marco Antonio; Clarêncio, Marcos; Lera Dos Santos, Marcos Eduardo; Franco, Matheus; Schneider, Nutianne Camargo; Mascarenhas, Ramiro; Roda, Rodrigo; Matuguma, Sérgio; Guaraldi, Simone; Figueiredo, Viviane

    2017-01-01

    At the time of its introduction in the early 80s, endoscopic ultrasonography (EUS) was indicated for diagnostic purposes. Recently, EUS has been employed to assist or to be the main platform of complex therapeutic interventions. From a series of relevant new topics in the literature and based on the need to complement the I Brazilian consensus on EUS, twenty experienced endosonographers identified and reviewed the pertinent literature in databases. The quality of evidence, strength of recommendations, and level of consensus were graded and voted on. Consensus was reached for eight relevant topics: treatment of gastric varices, staging of nonsmall cell lung cancer, biliary drainage, tissue sampling of subepithelial lesions (SELs), treatment of pancreatic fluid collections, tissue sampling of pancreatic solid lesions, celiac neurolysis, and evaluation of the incidental pancreatic cysts. There is a high level of evidence for staging of nonsmall cell lung cancer; biopsy of SELs as the safest method; unilateral and bilateral injection techniques are equivalent for EUS-guided celiac neurolysis, and in patients with visible ganglia, celiac ganglia neurolysis appears to lead to better results. There is a moderate level of evidence for: yield of tissue sampling of pancreatic solid lesions is not influenced by the needle shape, gauge, or employed aspiration technique; EUS-guided and percutaneous biliary drainage present similar clinical success and adverse event rates; plastic and metallic stents are equivalent in the EUS-guided treatment of pancreatic pseudocyst. There is a low level of evidence in the routine use of EUS-guided treatment of gastric varices.

  16. The concept of laparoscopy-assisted pancreatobiliary EUS (LAP-EUS).

    Science.gov (United States)

    Ramesh, Jayapal; Christein, John; Varadarajulu, Shyam

    2013-05-01

    While laparoscopy-assisted endoscopic retrograde cholangiopancreatography can be performed for the diagnosis and management of pancreaticobiliary diseases in patients with Roux-en-Y (RY) anatomy; the technical feasibility of performing laparoscopy-assisted endoscopic ultrasound (EUS) is unknown. In this report, we describe the technique for performing laparoscopy-assisted EUS in two patients with RY gastric bypass anatomy who presented with obstructive jaundice, abnormal liver function tests, and dilated biliary tree. While the examination was normal in one patient, EUS-guided fine needle aspiration of pancreatic head mass revealed adenocarcinoma in the other. Laparoscopic assisted EUS examination including FNA is feasible in Roux-en-Y surgical anatomy.

  17. Evaluation of multidetector computed tomography urography and ultrasonography for diagnosing bladder cancer

    Energy Technology Data Exchange (ETDEWEB)

    Knox, M.K. [Nuffield Department of Surgery, University of Oxford, Oxford (United Kingdom); Cowan, N.C. [Nuffield Department of Surgery, University of Oxford, Oxford (United Kingdom); Department of Radiology, Churchill Hospital, Oxford OX3 7LJ (United Kingdom)], E-mail: nigel.cowan@nds.ox.ac.uk; Rivers-Bowerman, M.D.; Turney, B.W. [Nuffield Department of Surgery, University of Oxford, Oxford (United Kingdom)

    2008-12-15

    Aim: To evaluate and compare the diagnostic accuracy of multidetector computed tomography urography (CTU) and ultrasonography (US) for diagnosing bladder cancer. Materials and methods: A consecutive series of 143 patients over 40-years of age, presenting with macroscopic haematuria and without urinary tract infection underwent same-day CTU, US, and flexible cystoscopy. CTU and US were independently rated on a five-point scale for the presence of bladder cancer without knowledge of the reference standard of flexible or rigid cystoscopy and/or biopsy results. Diagnostic accuracy was assessed by receiver operating characteristic (ROC) analysis and likelihood ratios. Results: For CTU, a rating of 5 (definitely tumour) was highly specific for bladder cancer (96.5%, 95%CI: 91.3-99%), effectively confirming diagnosis (positive likelihood ratio 25.6, 95%CI: 9.7-67.4). For US, specificity was also high (94.7%, 95%CI: 88.9-98%) with a positive likelihood ratio of 13.1 (95%CI: 5.8-29.6). Sensitivity at this rating was substantially higher for CTU (89.7%, 95%CI: 72.7-97.8%) than US (69%, 95%CI: 49.2-84.7%). Standardized partial area (A{sub z}) under the ROC curve between 95-100% specificity, representing the average sensitivity in this range, was significantly greater (0.88 versus 0.61, p < 0.05) for CTU than US. Conclusion: The specificities of CTU and US for the diagnosis of bladder cancer were similar, but CTU was more sensitive. Although the sensitivity of CTU was not high enough to replace flexible cystoscopy in the diagnostic pathway, the high specificity enables direct referral to rigid cystoscopy, bypassing flexible cystoscopy and expediting diagnosis and treatment in those patients testing positive.

  18. Evaluation of multidetector computed tomography urography and ultrasonography for diagnosing bladder cancer

    International Nuclear Information System (INIS)

    Knox, M.K.; Cowan, N.C.; Rivers-Bowerman, M.D.; Turney, B.W.

    2008-01-01

    Aim: To evaluate and compare the diagnostic accuracy of multidetector computed tomography urography (CTU) and ultrasonography (US) for diagnosing bladder cancer. Materials and methods: A consecutive series of 143 patients over 40-years of age, presenting with macroscopic haematuria and without urinary tract infection underwent same-day CTU, US, and flexible cystoscopy. CTU and US were independently rated on a five-point scale for the presence of bladder cancer without knowledge of the reference standard of flexible or rigid cystoscopy and/or biopsy results. Diagnostic accuracy was assessed by receiver operating characteristic (ROC) analysis and likelihood ratios. Results: For CTU, a rating of 5 (definitely tumour) was highly specific for bladder cancer (96.5%, 95%CI: 91.3-99%), effectively confirming diagnosis (positive likelihood ratio 25.6, 95%CI: 9.7-67.4). For US, specificity was also high (94.7%, 95%CI: 88.9-98%) with a positive likelihood ratio of 13.1 (95%CI: 5.8-29.6). Sensitivity at this rating was substantially higher for CTU (89.7%, 95%CI: 72.7-97.8%) than US (69%, 95%CI: 49.2-84.7%). Standardized partial area (A z ) under the ROC curve between 95-100% specificity, representing the average sensitivity in this range, was significantly greater (0.88 versus 0.61, p < 0.05) for CTU than US. Conclusion: The specificities of CTU and US for the diagnosis of bladder cancer were similar, but CTU was more sensitive. Although the sensitivity of CTU was not high enough to replace flexible cystoscopy in the diagnostic pathway, the high specificity enables direct referral to rigid cystoscopy, bypassing flexible cystoscopy and expediting diagnosis and treatment in those patients testing positive

  19. Improvement of diagnostic accuracy, and clinical evaluation of computed tomography and ultrasonography for deep seated cancers

    International Nuclear Information System (INIS)

    Arimizu, Noboru

    1980-01-01

    Cancers of the liver, gallbladder, and pancreas which were difficult to be detected at an early stage were studied. Diagnostic accuracy of CT and ultrasonography for vesectable small cancers was investigated by the project team and coworkers. Only a few cases of hepatocellular carcinoma, cancer of the common bile duct, and cancer of the pancreas head, with the maximum diameter of 1 - 2 cm, were able to be diagnosed by CT. There seemed to be more false negative cases with small cancers of that size. The limit of the size which could be detected by CT was thought to be 2 - 3 cm. Similar results were obtained by ultrasonography. Cancer of the pancreas body with the maximum diameter of less than 3.5 cm could not be detected by both CT and ultrasonography. Diagnostic accuracy of CT for liver cancer was improved by selective intraarterial injection of contrast medium. Improvement of the quality of ultrasonograms was achieved through this study. Merits and demerits of CT and ultrasonography were also compared. (Tsunoda, M.)

  20. Improvement of diagnostic accuracy, and clinical evaluation of computed tomography and ultrasonography for deep seated cancers

    Energy Technology Data Exchange (ETDEWEB)

    Arimizu, N [Chiba Univ. (Japan). School of Medicine

    1980-06-01

    Cancers of the liver, gallbladder, and pancreas which were difficult to be detected at an early stage were studied. Diagnostic accuracy of CT and ultrasonography for resectable small cancers was investigated by the project team and co-workers. Only a few cases of hepatocellular carcinoma, cancer of the common bile duct, and cancer of the pancreas head, with the maximum diameter of 1 - 2 cm, were able to be diagnosed by CT. There seemed to be more false negative cases with small cancers of that size. The limit of the size which could be detected by CT was thought to be 2 - 3 cm. Similar results were obtained by ultrasonography. Cancer of the pancreas body with the maximum diameter of less than 3.5 cm could not be detected by both CT and ultrasonography. Diagnostic accuracy of CT for liver cancer was improved by selective intraarterial injection of contrast medium. Improvement of the quality of ultrasonograms was achieved through this study. Merits and demerits of CT and ultrasonography were also compared.

  1. Imaging in early rheumatoid arthritis: roles of magnetic resonance imaging, ultrasonography, conventional radiography and computed tomography

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Ejbjerg, Bo; Szkudlarek, Marcin

    2005-01-01

    Efficient methods for diagnosis, monitoring and prognostication are essential in early rheumatoid arthritis (RA). While conventional X-rays only visualize the late signs of preceding disease activity, there is evidence for magnetic resonance imaging (MRI) and ultrasonography being highly sensitiv...

  2. Accuracy of EUS for estimating the depth of tumor invasion and for diagnosing lymph node metastasis and recurrence in patients with m3 and sm esophageal carcinomas

    International Nuclear Information System (INIS)

    Arima, Miwako; Tada, Masahiro; Tanaka, Youichi; Arima, Hideaki

    2006-01-01

    Esophagus-preserving therapy has been increasingly used to treat esophageal cancer invading the m 3 and sm, thereby avoiding radical surgery. However, many problems remain to be solved, including the diagnosis of lymph node metastasis and recurrence and the assessment of long-term outcomes. We studied 132 patients who had esophageal cancer with m 3 and sm invasion. Clinical course after esophagus-preserving therapy, and the accuracy and roles of endoscopic ultrasonography (EUS) for diagnosing the depth of tumor invasion, lymph node metastasis, and recurrence were assessed. EUS can be used to examine the cervical, thoracic, and abdominal regions, without being affected by heat beats. Therefore, EUS can more clearly depict lymph nodes than CT or US. The accuracy of EUS was 86.4% for estimating the depth of tumor invasion and 82% for diagnosing lymph node metastasis. All cases of nodal recurrence were diagnosed by EUS. Among patients who received chemoradiotherapy, enlarged lymph nodes often appeared around 3 years after treatment, and recurrence was diagnosed slightly later than that in patients who underwent endoscopic mucosal resection. Endoscopic ultrasound-guided fine-needle aspiration biopsy was sometimes performed to determine the treatment policy. Patients who receive chemoradiotherapy should undergo regular long-term follow-up by CT, US, and EUS. EUS is essential for the earlier detection of recurrence. (author)

  3. Medullary cystic disease of the kidney: report of a case diagnosed by ultrasonography and computed tomography examinations

    International Nuclear Information System (INIS)

    Carvalho, Tarcisio Nunes; Araujo Junior, Cyrillo Rodrigues de; Fraguas Filho, Sergio Roberto; Costa, Marlos Augusto Bittencourt; Teixeira, Kim-Ir-Sen Santos; Ribeiro, Flavia Aparecida de Souza

    2003-01-01

    The terms medullary cystic disease, juvenile nephronophthisis or medullary cystic disease complex refer to a group of similar diseases in which the basic pathological abnormality is progressive renal tubular atrophy with secondary glomerular sclerosis and medullary cystic formation. Medullary cystic disease is an important cause of renal failure in adolescent patients. Imaging methods play a primary role in the diagnosis of these diseases. Cysts are characteristically seen in the renal medulla and cortico medullary junction whereas kidneys may be of normal to small size. In this article we present the ultrasonography and computed tomography findings of a female adolescent patient with characteristic clinical picture of medullary cystic disease. (author)

  4. Transgastric pure-NOTES peritoneoscopy and endoscopic ultrasonography for staging of gastrointestinal cancers

    DEFF Research Database (Denmark)

    Donatsky, Anders Meller; Vilmann, Peter; Meisner, Søren

    2012-01-01

    BACKGROUND: Human natural orifice transluminal endoscopic surgery (NOTES) has mainly been based on simultaneous laparoscopic assistance (hybrid NOTES), forgoing the theoretical benefits of the NOTES technique. This is due to a lack of NOTES-specific instruments and endoscopes, making pure-NOTES...... procedures difficult and time consuming. An area where pure NOTES could be adopted at its present stage of development is minimally invasive staging of gastrointestinal (GI) cancer. The aim of this study is to evaluate the feasibility of combining transgastric (TG) pure-NOTES peritoneoscopy...... and intraperitoneal endoscopic ultrasonography (ip-EUS) with intraluminal EUS (il-EUS) for peritoneal evaluation. METHODS: This was a feasibility and survival study where il-EUS followed by ip-EUS and peritoneoscopy was performed in 10 pigs subjected to TG pure NOTES. A score was given with regard to achieved...

  5. Gastrointestinal diseases in HIV-positive patients: ultrasonography and computed tomography in a study of 85 patients

    International Nuclear Information System (INIS)

    Garcia, S.; Yague, D.; Garcia, C.; Villalon, M.; Pascual, A.; Artigas, J.M.

    1998-01-01

    Gastrointestinal diseases constitute the second most common group conditions affecting HIV-positive patients after respiratory diseases. Gastrointestinal involvement may even be the first sign of the disease, a facto which demonstrates the importance of its proper assessment. To demonstrate the utility of computed tomography and ultrasound in the study of gastrointestinal and hepatobiliary diseases in the HIV-positive patient. We review a series of 85 HIV-positive patients presenting gastrointestinal symptomatology who underwent ultrasonography and/or computed tomography. the definitive diagnosis was achieved in all the patients by microbiological or histopathological means. In our series 36.4% the patients had presented systemic TB, 23.52% CMV infection, 17.64% Cryptosporidium infection and 17.64% MAI infection. Much lower incidences were found for Mycobacterium xenopi. M. kansai and Leishmania infection. The presence of lymphoma was confirmed in 7.05% of the patients and Koposi's sarcoma in 0.95%. In these patients, the most common finding on imaging studies in lymph node involvement, followed by diffuse hepatosplenomegaly. Imaging techniques, especially ultrasonography and computed tomography, are useful in these patients: although they do not provide the diagnosis, they do contribute data of prognostic and therapeutic importance. (Author) 11 refs

  6. Comparison of cone-beam computed tomography and ultrasonography on experimental bone lesion

    International Nuclear Information System (INIS)

    Kim, Min Sung; Park, Cheol Woo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2010-01-01

    This study was performed to evaluate the diagnostic ability of ultrasonography in detection of bone defects and new bone formation. Experimental bony defects were prepared on the parietal bone samples acquired from 3.5 kg New Zealand male rabbits. The defects were evaluated using ultrasonography and CBCT, and examined histologically at interval of 1, 3, 6, and 8 weeks. Ultrasonograph demonstrated hyperechogenicity in the defect area at 3 weeks and broadened hyperechogenicity from the margin of bone defect at 6 and 8 weeks due to new bone formation. On the CBCT images, new bone formation was first observed at 3 weeks around the margin of the defect, and showed gradually increase at 6 and 8 weeks. Histologic findings revealed existence of the fibroblasts and fibrous connective tissue with abundant capillary vessels only at 1 week, but osteoid tissue and newly formed trabecular bone at 3 weeks. Bone remodeling in the defect area was observed at 6 weeks and increased calcification and dense trabecular bone formation was observed at 8 weeks. Ultrasonograph proved to be a very useful diagnostic tool in detecting the bony defect and new bone formation. Additionally, ultrasonography provided valuable information regarding the blood supply around the defect area.

  7. Contrast-enhanced endoscopic ultrasonography in digestive diseases.

    Science.gov (United States)

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2012-10-01

    Contrast-enhanced endoscopic ultrasonography (CE-EUS) was introduced in the early 1990s. The concept of the injection of carbon dioxide microbubbles into the hepatic artery as a contrast material (enhanced ultrasonography) led to "endoscopic ultrasonographic angiography". After the arrival of the first-generation contrast agent, high-frequency (12 MHz) EUS brought about the enhancement of EUS images in the diagnosis of pancreatico-biliary diseases, upper gastrointestinal (GI) cancer, and submucosal tumors. The electronic scanning endosonoscope with both radial and linear probes enabled the use of high-end ultrasound machines and depicted the enhancement of both color/power Doppler flow-based imaging and harmonic-based imaging using second-generation contrast agents. Many reports have described the usefulness of the differential diagnosis of pancreatic diseases and other abdominal lesions. Quantitative evaluation of CE-EUS images was an objective method of diagnosis using the time-intensity curve (TIC), but it was limited to the region of interest. Recently developed Inflow Time Mapping™ can be generated from stored clips and used to display the pattern of signal enhancement with time after injection, offering temporal difference of contrast agents and improved tumor characterization. On the other hand, three-dimensional CE-EUS images added new information to the literature, but lacked positional information. Three-dimensional CE-EUS with accurate positional information is awaited. To date, most reports have been related to pancreatic lesions or lymph nodes. Hemodynamic analysis might be of use for diseases in other organs: upper GI cancer diagnosis, submucosal tumors, and biliary disorders, and it might also provide functional information. Studies of CE-EUS in diseases in many other organs will increase in the near future.

  8. Small intestine contrast ultrasonography vs computed tomography enteroclysis for assessing ileal Crohn's disease

    Science.gov (United States)

    Onali, Sara; Calabrese, Emma; Petruzziello, Carmelina; Zorzi, Francesca; Sica, Giuseppe; Fiori, Roberto; Ascolani, Marta; Lolli, Elisabetta; Condino, Giovanna; Palmieri, Giampiero; Simonetti, Giovanni; Pallone, Francesco; Biancone, Livia

    2012-01-01

    AIM: To compare computed tomography enteroclysis (CTE) vs small intestine contrast ultrasonography (SICUS) for assessing small bowel lesions in Crohn's disease (CD), when using surgical pathology as gold standard. METHODS: From January 2007 to July 2008, 15 eligible patients undergoing elective resection of the distal ileum and coecum (or right colon) were prospectively enrolled. All patients were under follow-up. The study population included 6 males and 9 females, with a median age of 44 years (range: 18-80 years). Inclusion criteria: (1) certain diagnosis of small bowel requiring elective ileo-colonic resection; (2) age between 18-80 years; (3) elective surgery in our Surgical Unit; and (4) written informed consent. SICUS and CTE were performed ≤ 3 mo before surgery, followed by surgical pathology. The following small bowel lesions were blindly reported by one sonologist, radiologist, surgeon and histolopathologist: disease site, extent, strictures, abscesses, fistulae, small bowel dilation. Comparison between findings at SICUS, CTE, surgical specimens and histological examination was made by assessing the specificity, sensitivity and accuracy of each technique, when using surgical findings as gold standard. RESULTS: Among the 15 patients enrolled, CTE was not feasible in 2 patients, due to urgent surgery in one patients and to low compliance in the second patient, refusing to perform CTE due to the discomfort related to the naso-jejunal tube. The analysis for comparing CTE vs SICUS findings was therefore performed in 13 out of the 15 CD patients enrolled. Differently from CTE, SICUS was feasible in all the 15 patients enrolled. No complications were observed when using SICUS or CTE. Surgical pathology findings in the tested population included: small bowel stricture in 13 patients, small bowel dilation above ileal stricture in 10 patients, abdominal abscesses in 2 patients, enteric fistulae in 5 patients, lymphnodes enlargement (> 1 cm) in 7 patients and

  9. Asian EUS Cup-05: Successful management of peripancreatic tumors by endoscopic ultrasound-guided radiofrequency ablation

    OpenAIRE

    Oh, Dongwook; Seo, Dong Wan

    2017-01-01

    Background: Endoscopic ultrasound-guided radiofrequency ablation (EUS-RFA) could be used as an effective alternative treatment for peripancreatic tumor. Herein, we reported a case of adrenal adenoma which was treated by EUS-RFA. Case Report: A 38-year-old woman presented with ?moon face,? ?buffalo hump,? and weight gain of 9 kg in 12 months. Initial contrast-enhanced abdominal computed tomography showed a 2.8 cm left adrenal mass, and the patient was diagnosed with Cushing?s syndrome due to l...

  10. Self-aggregation of magnetic semiconductor EuS nanocrystals

    International Nuclear Information System (INIS)

    Tanaka, Atsushi; Hasegawa, Yasuchika; Kamikubo, Hironari; Kataoka, Mikio; Kawai, Tsuyoshi

    2009-01-01

    Controlled formation of aggregates having organized structure of cube-shaped EuS nanocrystals is reported. The EuS aggregates in liquid media (methanol) were obtained by means of van der Waals interaction between EuS nanocrystals. The packing structure of the EuS aggregates is characterized with transmission electron microscopy (TEM) and small angle X-ray scattering measurements (SAXS). TEM image indicates the EuS nanocrystals form self-aggregated 2D orthogonal lattice structure. The diffraction peak of (111) of SAXS profile shows that the cube-shaped EuS form 3D cubic superlattice. We successfully demonstrated that the aggregates of cube-shaped EuS nanocrystals formed cubic stacking structure.

  11. Value of computed tomography for evaluating the injection site in endosonography-guided celiac plexus neurolysis

    International Nuclear Information System (INIS)

    Sakamoto, Hiroki; Kitano, Masayuki; Nishio, Takeshi; Takeyama, Yoshifumi; Yasuda, Chikao; Kudo, Masatoshi

    2006-01-01

    Endosonography-guided celiac plexus neurolysis (EUS-CPN) safely and effectively relieves pain associated with intra-abdominal malignancies when the neurolytic is accurately injected. We applied contrast medium to evaluate the ethanol injection sites in patients who received EUS-CPN due to abdominal pain caused by malignancies. We injected, under the guidance of endoscopic ultrasonography (EUS), ethanol containing 10% contrast medium into the celiac plexus of patients with intra-abdominal pain due to malignancies. Immediately after the endoscopic therapy, patients underwent computed tomography (CT) to confirm the injection site. Images of distribution of injected solutions were classified into three groups. Injected solution dispersed in unilateral and bilateral anterocrural space was defined as ''unilateral injection'' or bilateral injection'', respectively. Injected solution located out of the anterocrural space was defined as ''inappropriate injection''. Pre- and postprocedure pain was assessed using a standard analog scale. Before and 2, 4, 8, 12, and 16 weeks after the procedure, pain scores were evaluated. From April 2003 to May 2005, 13 patients were enrolled in this study. Improvement of pain score in the ''bilateral injection'' and ''unilateral injection'' groups was significantly superior to the change in the ''inappropriate injection'' group. Although EUS-CPN was effective in eight of 13 patients (61.5%), additional EUS-CPN to the ''inappropriate injection group'' increased the response rate to 84.6%. Injection of ethanol to the anterocrural space by EUS-CPN produced adequate pain relief. Immediate examination by CT for confirmation of injection sites after EUS-CPN would increase the likelihood of induction of pain relief. (author)

  12. Pancreatic duct drainage using EUS-guided rendezvous technique for stenotic pancreaticojejunostomy.

    Science.gov (United States)

    Takikawa, Tetsuya; Kanno, Atsushi; Masamune, Atsushi; Hamada, Shin; Nakano, Eriko; Miura, Shin; Ariga, Hiroyuki; Unno, Jun; Kume, Kiyoshi; Kikuta, Kazuhiro; Hirota, Morihisa; Yoshida, Hiroshi; Katayose, Yu; Unno, Michiaki; Shimosegawa, Tooru

    2013-08-21

    The patient was a 30-year-old female who had undergone excision of the extrahepatic bile duct and Roux-en-Y hepaticojejunostomy for congenital biliary dilatation at the age of 7. Thereafter, she suffered from recurrent acute pancreatitis due to pancreaticobiliary maljunction and received subtotal stomach-preserving pancreaticoduodenectomy. She developed a pancreatic fistula and an intra-abdominal abscess after the operation. These complications were improved by percutaneous abscess drainage and antibiotic therapy. However, upper abdominal discomfort and the elevation of serum pancreatic enzymes persisted due to stenosis from the pancreaticojejunostomy. Because we could not accomplish dilation of the stenosis by endoscopic retrograde cholangiopancreatography, we tried an endoscopic ultrasonography (EUS) guided rendezvous technique for pancreatic duct drainage. After transgastric puncture of the pancreatic duct using an EUS-fine needle aspiration needle, the guidewire was inserted into the pancreatic duct and finally reached to the jejunum through the stenotic anastomosis. We changed the echoendoscope to an oblique-viewing endoscope, then grasped the guidewire and withdrew it through the scope. The stenosis of the pancreaticojejunostomy was dilated up to 4 mm, and a pancreatic stent was put in place. Though the pancreatic stent was removed after three months, the patient remained symptom-free. Pancreatic duct drainage using an EUS-guided rendezvous technique was useful for the treatment of a stenotic pancreaticojejunostomy after pancreaticoduodenectomy.

  13. Endoscopic ultrasonography and rectal duplication cyst in an adult.

    Science.gov (United States)

    Castro-Poças, Fernando M; Araújo, Tarcísio P; Silva, Jorge D; Gonçalves, Vicente S

    2017-01-01

    Rectal duplication cysts account for 4% of all duplications of the alimentary tract. Presentation in adulthood is rare. An asymptomatic 54-year-old man was referred for endoscopic colorectal cancer screening. A bulging mass covered by normal mucosa was identified in the rectum. Endoscopic ultrasonography (EUS) with fine needle aspiration (FNA) was made for a diagnosis of rectal duplication cyst. The patient was operated and the diagnosis was confirmed. The diagnosis of the rectal duplication cyst is a challenge. EUS may have a singular role when identifying a muscular layer, because this is the only absolutely necessary criterion for the diagnosis. FNA by EUS may eventually identify colorectal and/or heterotypic epithelium that are the other diagnostic criteria of the duplication cyst.

  14. Two cases of schistosomiasis japonica diagnosed on computed tomography and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Seki, Tatsuo; Midorikawa, Shigeo; Hagiri, Masumi; Itoh, Haruhisa; Haku, Eijitsu (Teikyo Univ., Tokyo (Japan). Faculty of Medicine)

    1982-12-01

    We reported two cases of schistosomiasis japonica which showed pathognomonic pattern on liver C.T. and ultrasonography. Schistosomiasis japonica is an endemic disease in areas of Japan, but only chronic case of the disease is found now since Schistosoma Japonicum is thought to be died out in Japan. The adult worms are most commonly in branches of portal system, such as superior mesenteric vein, and many eggs are carried to the liver, where they cause inflammatory pseudotubercle formation, periportal fibrosis, and calcifications in interlobular connective tissue. According to Nakayama et al, pathognomonic pattern of schistosomiasis japonica on U.S. for the liver consists of the amounts of the eggs' calcifications, that is, the more eggs' calcifications, the more pathognomonic U.S. finding. Typical sonographic finding in the liver is network or fishscale pattern, which consists of streaky high level echo and internal low level echo. C.T. similarly demonstrates mosaic high density streak resulting from eggs' calcifications in peripheral portal branches. In addition, if patient's past history shows the life in the endemic area such as these two cases, we can easily make a diagnosis of ''schistosomiasis japonica''.

  15. Two cases of schistosomiasis japonica diagnosed on computed tomography and ultrasonography

    International Nuclear Information System (INIS)

    Seki, Tatsuo; Midorikawa, Shigeo; Hagiri, Masumi; Itoh, Haruhisa; Haku, Eijitsu

    1982-01-01

    We reported two cases of schistosomiasis japonica which showed pathognomonic pattern on liver C.T. and ultrasonography. Schistosomiasis japonica is an endemic disease in areas of Japan, but only chronic case of the disease is found now since Schistosoma Japonicum is thought to be died out in Japan. The adult worms are most commonly in branches of portal system, such as superior mesenteric vein, and many eggs are carried to the liver, where they cause inflammatory pseudotubercle formation, periportal fibrosis, and calcifications in interlobular connective tissue. According to Nakayama et al, pathognomonic pattern of schistosomiasis japonica on U.S. for the liver consists of the amounts of the eggs' calcifications, that is, the more eggs' calcifications, the more pathognomonic U.S. finding. Typical sonographic finding in the liver is network or fishscale pattern, which consists of streaky high level echo and internal low level echo. C.T. similarly demonstrates mosaic high density streak resulting from eggs' calcifications in peripheral portal branches. In addition, if patient's past history shows the life in the endemic area such as ours two cases, we can easily make a diagnosis of ''schistosomiasis japonica''

  16. Spin fluctuations in EuS

    International Nuclear Information System (INIS)

    Hartmann, A.

    1996-02-01

    Demagnetization effects break the isotropy of spin waves. During spring 1995, Peter Boeni et al. performed polarized neutron measurements on EuS using the triple axis spectrometer IN14 at the ILL in Grenoble, in order to investigate the influence of dipolar interactions on the spin waves. In the following work the analysis of the experimental data is described. (author) 25 figs., 2 tabs., 9 refs

  17. Rescue EUS-guided intrahepatic biliary drainage for malignant hilar biliary stricture after failed transpapillary re-intervention.

    Science.gov (United States)

    Minaga, Kosuke; Takenaka, Mamoru; Kitano, Masayuki; Chiba, Yasutaka; Imai, Hajime; Yamao, Kentaro; Kamata, Ken; Miyata, Takeshi; Omoto, Shunsuke; Sakurai, Toshiharu; Watanabe, Tomohiro; Nishida, Naoshi; Kudo, Masatoshi

    2017-11-01

    Treatment of unresectable malignant hilar biliary stricture (UMHBS) is challenging, especially after failure of repeated transpapillary endoscopic stenting. Endoscopic ultrasonography-guided intrahepatic biliary drainage (EUS-IBD) is a recent technique for intrahepatic biliary decompression, but indications for its use for complex hilar strictures have not been well studied. The aim of this study was to assess the feasibility and safety of EUS-IBD for UMHBS after failed transpapillary re-intervention. Retrospective analysis of all consecutive patients with UMHBS of Bismuth II grade or higher who, between December 2008 and May 2016, underwent EUS-IBD after failed repeated transpapillary interventions. The technical success, clinical success, and complication rates were evaluated. Factors associated with clinical ineffectiveness of EUS-IBD were explored. A total of 30 patients (19 women, median age 66 years [range 52-87]) underwent EUS-IBD for UMHBS during the study period. Hilar biliary stricture morphology was classified as Bismuth II, III, or IV in 5, 13, and 12 patients, respectively. The median number of preceding endoscopic interventions was 4 (range 2-14). EUS-IBD was required because the following procedures failed: duodenal scope insertion (n = 4), accessing the papilla after duodenal stent insertion (n = 5), or achieving desired intrahepatic biliary drainage (n = 21). Technical success with EUS-IBD was achieved in 29 of 30 patients (96.7%) and clinical success was attained in 22 of these 29 (75.9%). Mild peritonitis occurred in three of 30 (10%) and was managed conservatively. Stent dysfunction occurred in 23.3% (7/30). There was no procedure-related mortality. On multivariable analysis, Bismuth IV stricture predicted clinical ineffectiveness (odds ratio = 12.7, 95% CI 1.18-135.4, P = 0.035). EUS-IBD may be a feasible and effective rescue alternative with few major complications after failed transpapillary endoscopic re-intervention in patients

  18. Role of endoscopic ultrasonography in treatment and prognostic evaluation of esophageal and gastric varices

    Directory of Open Access Journals (Sweden)

    LI Shuang

    2016-12-01

    Full Text Available Through a comprehensive evaluation of collateral circulation establishment in portal hypertension, endoscopic ultrasonography (EUS not only helps to predict and evaluate the risks of first bleeding from esophageal and gastric varices and recurrence and rebleeding after treatment, but also guides and participates in the treatment of varices. This article introduces the unique advantages of EUS in the treatment and prognostic evaluation of esophageal and gastric varices and provides an important reference for individualized treatment of patients with liver cirrhosis complicated by esophageal and gastric varices. EUS also helps to improve treatment safety and response rate. EUS for the systematic treatment of portal hypertension has become a hot research topic in recent years.

  19. The endoscopic ultrasonography-guided rendezvous technique for biliary cannulation: a technical review.

    Science.gov (United States)

    Isayama, Hiroyuki; Nakai, Yousuke; Kawakubo, Kazumichi; Kawakami, Hiroshi; Itoi, Takao; Yamamoto, Natsuyo; Kogure, Hirofumi; Koike, Kazuhiko

    2013-04-01

    Steady progress is being made in endoscopic biliary intervention, especially endoscopic ultrasonography (EUS)-guided procedures. The EUS-guided rendezvous technique (EUS-RV) is a salvage method for failed selective biliary cannulation. The overall success rate of EUS-RV in 247 cases from seven published articles was 74 % and the incidence of complications was 11 %. The main cause of failed rendezvous cannulation was difficulty passing a biliary stricture or papilla due to poor guidewire (GW) manipulation. A recent large study found a 98.3 % success rate and superiority to precutting. This report suggested using a hydrophilic guidewire. Major complications were bleeding (0.8 %), bile leakage (1.2 %), peritonitis (0.4 %), pneumoperitoneum (0.2 %), and pancreatitis (1.6 %). The approach routes for EUS-RV were transgastric, transduodenal short position, and transduodenal long position. The appropriate route for each patient should be used. GW selection for EUS-RV is critical, and a hydrophilic GW might be the most useful. The catheter can be inserted through the papilla alongside or over the wire. Alongside cannulation is convenient, but difficult. The problem with the over-the-wire technique is withdrawal of the GW in the accessory channel. EUS-RV is effective and safe, but is not established. The efficacy should be confirmed in a prospective comparative trial, and the necessary specialist equipment should be developed.

  20. The utility and yield of endoscopic ultrasonography for suspected choledocholithiasis in common gastroenterology practice.

    Science.gov (United States)

    Quispel, Rutger; van Driel, Lydi M W J; Veldt, Bart J; van Haard, Paul M M; Bruno, Marco J

    2016-12-01

    Endoscopic ultrasonography (EUS) is an established diagnostic modality for diagnosing common bile duct (CBD) stones. Its use has led to a reduction in the number of endoscopic retrograde cholangiopancreatography (ERCP) procedures performed for suspected choledocholithiasis. We aimed to explore the role of EUS in detecting CBD stones and/or sludge in common gastroenterology practice. We reviewed case records of 268 consecutive patients who underwent (EUS) procedures performed to confirm or rule out the presence of CBD stones and/or sludge between November 2006 and January 2011 in the Reinier de Graaf Hospital, Delft, The Netherlands, which is a nonacademic community hospital. On the basis of EUS findings, 169 of 268 (63%) patients did not undergo ERCP and were therefore not exposed to its risk of complications. Patients with positive findings on EUS (n=99) all underwent ERCP and endoscopic sphincterotomy. Only 57 of 99 (58%) had positive findings at ERCP. The main contributing factors to this finding seem to be time interval between EUS and ERCP and the type of CBD content (i.e. sludge, one CBD stone or more than one CBD stone) described. In our common gastroenterology practice, EUS plays an important role in selecting patients suspected to have CBD stones or sludge for ERCP. Much is to be learned about the probability of spontaneous passage of CBD stones and sludge into the duodenum.

  1. Comparison between MRI with MR cholangiopancreatography and endoscopic ultrasonography for differentiating malignant from benign mucinous neoplasms of the pancreas

    International Nuclear Information System (INIS)

    Hwang, Jiyoung; Hong, Seong Sook; Kim, Hyun-joo; Kim, Young Kon; Jeong, Woo Kyung; Min, Ji Hye

    2018-01-01

    To compare diagnostic performance of magnetic resonance imaging (MRI) and endoscopic ultrasonography (EUS) for differentiating malignant from benign intraductal papillary mucinous neoplasms (IPMN) and mucinous cystic neoplasms (MCN) of the pancreas. This retrospective study included 55 patients with 47 surgically confirmed IPMNs (12 malignant, 35 benign) and eight MCNs (two malignant, six benign) who underwent contrast-enhanced pancreas MRI and EUS. Contrast enhancement was not routinely used at EUS examination. Two observers independently evaluated the MRIs, and another reviewed EUS images. They recorded their confidence for malignancy with each imaging modality. We calculated diagnostic performance using the area under the receiver operating characteristic curves (A z ), and to determine the accuracy, sensitivity, specificity, and positive (PPV) and negative predictive (NPV) values. The A z values of MRI were higher than those of EUS (0.712 and 0.688 for MRI vs. 0.543 for EUS; p = 0.007). The diagnostic accuracies (74.5%), specificity (78.0% and 80.5%) and PPV (50.0%) of MRI in two observers were higher than those (56.4%, 58.5% and 29.2%, respectively) of EUS (p = 0.013-0.049). MRI showed better diagnostic performance than EUS for differentiating malignant from benign pancreatic IPMN and MCN. (orig.)

  2. Comparison between MRI with MR cholangiopancreatography and endoscopic ultrasonography for differentiating malignant from benign mucinous neoplasms of the pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jiyoung; Hong, Seong Sook; Kim, Hyun-joo [Seoul Hospital, Department of Radiology, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of); Kim, Young Kon; Jeong, Woo Kyung [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Min, Ji Hye [Chungnam National University College of Medicine, Department of Radiology, Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2018-01-15

    To compare diagnostic performance of magnetic resonance imaging (MRI) and endoscopic ultrasonography (EUS) for differentiating malignant from benign intraductal papillary mucinous neoplasms (IPMN) and mucinous cystic neoplasms (MCN) of the pancreas. This retrospective study included 55 patients with 47 surgically confirmed IPMNs (12 malignant, 35 benign) and eight MCNs (two malignant, six benign) who underwent contrast-enhanced pancreas MRI and EUS. Contrast enhancement was not routinely used at EUS examination. Two observers independently evaluated the MRIs, and another reviewed EUS images. They recorded their confidence for malignancy with each imaging modality. We calculated diagnostic performance using the area under the receiver operating characteristic curves (A{sub z}), and to determine the accuracy, sensitivity, specificity, and positive (PPV) and negative predictive (NPV) values. The A{sub z} values of MRI were higher than those of EUS (0.712 and 0.688 for MRI vs. 0.543 for EUS; p = 0.007). The diagnostic accuracies (74.5%), specificity (78.0% and 80.5%) and PPV (50.0%) of MRI in two observers were higher than those (56.4%, 58.5% and 29.2%, respectively) of EUS (p = 0.013-0.049). MRI showed better diagnostic performance than EUS for differentiating malignant from benign pancreatic IPMN and MCN. (orig.)

  3. Transgastric pure-NOTES peritoneoscopy and endoscopic ultrasonography for staging of gastrointestinal cancers: a survival and feasibility study.

    Science.gov (United States)

    Donatsky, Anders Meller; Vilmann, Peter; Meisner, Søren; Jørgensen, Lars Nannestad; Rosenberg, Jacob

    2012-06-01

    Human natural orifice transluminal endoscopic surgery (NOTES) has mainly been based on simultaneous laparoscopic assistance (hybrid NOTES), forgoing the theoretical benefits of the NOTES technique. This is due to a lack of NOTES-specific instruments and endoscopes, making pure-NOTES procedures difficult and time consuming. An area where pure NOTES could be adopted at its present stage of development is minimally invasive staging of gastrointestinal (GI) cancer. The aim of this study is to evaluate the feasibility of combining transgastric (TG) pure-NOTES peritoneoscopy and intraperitoneal endoscopic ultrasonography (ip-EUS) with intraluminal EUS (il-EUS) for peritoneal evaluation. This was a feasibility and survival study where il-EUS followed by ip-EUS and peritoneoscopy was performed in 10 pigs subjected to TG pure NOTES. A score was given with regard to achieved visualisation of predefined anatomical structures. Survival was assessed at postoperative day (POD) 14. All animals survived until POD 14. Median total procedural time was 94 min (range 74-130 min). Median time for il-EUS, ip-EUS and peritoneoscopy was 11 min (range 7-14 min), 13 min (range 8-20 min) and 10 min (range 6-23 min). Il-EUS, ip-EUS and peritoneoscopy resulted in a score of 15/15 points (range 14-15 points), 6/9 points (range 1-8 points) and 12/13 points (range 8-13 points). TG pure-NOTES peritoneoscopy and ip-EUS combined with il-EUS is feasible and provides sufficient peritoneal evaluation. The technique could have potential for minimally invasive staging of GI cancers.

  4. Ultrasonography, angiography, computed tomography and magnetic resonance in nodular regenerative hyperplasia of the liver

    International Nuclear Information System (INIS)

    Patriarche, C.; Pelletier, G.; Attali, P.; Ladouch-Badre, A.; Fabre, M.; Roche, A.; Etienne, J.P.

    1988-01-01

    Ultrasonographic, computed tomographic, and angiographic abnormalities of nodular regenerative hyperplasia have been described in very few cases. We report here the case of a 50-year-old man with round, well-limited hypoechogenic lesions involving the two lobes of the liver, and hypervascular, poorly delineated angiographic lesions. Computed tomography and magnetic resonance of the liver were normal. Histological examination of large liver specimens provided by intraoperative biopsy allowed the diagnosis of nodular regenerative hyperplasia. Such a pseudo-tumoral ultrasonographic and angiographic pattern must be recognized in order to avoid diagnostic and therapeutic mistakes, especially since percutaneous liver biopsy usually fails to diagnose this disease. (author)

  5. The efficacy of ultrasonography in hemodynamically stable children with blunt abdominal trauma: a prospective comparison with computed tomography

    International Nuclear Information System (INIS)

    Tas, Fikret; Ceran, Canan; Atalar, Mehmet H.; Bulut, Sema; Selbes, Bilge; Isik, A. Oktay

    2004-01-01

    Purpose: In this prospective study we aimed to investigate the diagnostic value of ultrasonography (US) in hemodynamically stable children after blunt abdominal trauma (BAT) using computed tomography (CT) as the gold standard. Materials and methods: Between 1997 and 2001, 96 children with BAT were evaluated prospectively. CT was performed first, followed by US. US and CT examinations were independently evaluated by two radiologists for free fluid and organ injury. The sensitivity, specificity, positive predictive value, negative predictive value and overall accuracy of US were assessed regarding CT as the gold standard. Results: Overall 128 organ injuries were determined in 96 patients with CT; however, 20 (15.6%) of them could not be seen with US. Free intraabdominal fluid (FIF) was seen in 82 of 96 patients by CT (85.4%) and eight of them (9.7%) could not be seen by US. We found that sensitivity, specificity, positive predictive value, negative predictive value and overall accuracy of the US for free intra-abdominal fluid were 90.2, 100, 100, 63.6 and 91.7%, respectively. Conclusions: US for BAT in children is highly accurate and specific. It is highly sensitive in detecting liver, spleen and kidney injuries whereas its sensitivity is moderate for the detection of gastrointestinal tract (GIT) and pancreatic injuries

  6. Contrast-enhanced ultrasonography and spiral computed tomography in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Sandro; Ghittoni, Giorgia; Ravetta, Valentina; Torello Viera, Francesca; Rosa, Laura [Policlinico ' S. Matteo' Foundation, IRCCS, VI Department of Internal Medicine and Interventional Ultrasonography, Pavia (Italy); Serassi, Martina; Scabini, Mara; Vercelli, Alessandro; Calliada, Fabrizio [IRCCS Policlinico ' S. Matteo' , Department of Radiology, P.le Golgi n. 19, Pavia (Italy); Tinelli, Carmine [Biometrics Unit, IRCCS Policlinico ' S. Matteo' , Pavia (Italy); Dal Bello, Barbara [IRCCS Policlinico ' S. Matteo' , Department of Human Pathology, Pavia (Italy); Burns, Peter N. [University of Toronto, Department of Medical Biophysics, Toronto, ON (Canada); Imaging Research S660, Sunnybrook Health Science Centre, Toronto, ON (Canada)

    2008-08-15

    The aim was to compare the performances of contrast-enhanced (CE) ultrasonography (US) and spiral computed tomography (CT) in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma (HCC). We studied 50 patients with HCC who had biopsy-proven portal vein thrombi that had been detected with US and color Doppler US. Thirteen of the thrombi involved the main portal trunk and 37 the segmental branches. CEUS and CT were performed within a week of thrombus biopsies. For each imaging technique, diagnoses of thrombosis (present/absent) and thrombus nature (malignancy/benignancy) were made by experienced readers under blinded conditions and compared with pathological findings to determine accuracy rates for thrombus detection and characterization. Forty-four of the 50 thrombi were pathologically diagnosed as malignant and the remaining six were benign. CEUS detected 50/50 (100%) thrombi and correctly characterized 49/50 (98%). CT detected 34/50 (68%) thrombi and correctly characterized 23 of these 34 (68%). CEUS outperformed CT in terms of both thrombus detection (P < 0.0001) and characterization (P = 0.0001). CEUS appears to be significantly superior to CT for detection and characterization of portal vein thrombosis complicating HCC, and it should be considered in the staging of these tumors. (orig.)

  7. Efficacy for preoperative screening of liver metastasis using computed tomography and ultrasonography in patients with colon cancer

    International Nuclear Information System (INIS)

    Kotanagi, Hitoshi; Sato, Emi; Murakoshi, Satoshi

    2000-01-01

    To establish an effective examination system for preoperative evaluation of liver metastasis by colon cancer, we analyzed the sensitivity, cost, and efficacy of computed tomography (CT) and ultrasonography (US) in 354 patients (including 63 patients with liver metastasis). The presence or absence of liver metastasis was ultimately diagnosed 5 years after the operation. The sensitivity, specificity, and accuracy for detecting liver metastasis were 65%, 94%, and 89%, respectively for CT, 57%, 97%, and 91% for US, and 65%, 93%, and 88% for CT plus US, and there were no significant differences among them. Neither CT nor US could fully detect intrahepatic cancer spread. The cost of detection of one patient with liver metastasis was 6,298 points for plain CT, 20,169 points for enhanced CT, and 5,773 points for US. It was concluded that CT plus US should not be employed for preoperative assessment of liver metastasis, because the detection rate of the two modalities is not significantly different, and these modalities do not compensate for each other's defects. From the standpoint of the cost-benefit relationship, US should be selected for preoperative evaluation of liver metastasis. (author)

  8. Cine magnetic resonance imaging, computed tomography and ultrasonography in the evaluation of chest wall invasion of lung cancer

    International Nuclear Information System (INIS)

    Yokozaki, Michiya; Nawano, Shigeru; Nagai, Kanji; Moriyama, Noriyuki; Kodama, Tetsuro; Nishiwaki, Yutaka.

    1997-01-01

    To assess the usefulness of cine-magnetic resonance imaging (cine-MRI) in the evaluation of chest wall invasion, we compared the results of cine-MRI with those of computed tomography (CT) and ultrasonography (US). Eleven patients were examined who had no pain and who were difficult to diagnose by routine examinations. MRI was performed with a Magnetom SP/4000, 1.5T unit (Siemens, Germany). For cine imaging, continuous turbo-FLUSH (ultra fast low angle shot) images were obtained at an orthogonal section to the chest wall during slow deep breathing. A CT scan was performed using a TCT 900S or Super Helix (Toshiba, Japan) at 1 cm intervals, with section thicknesses of 1 cm throughout the entire chest. US was performed with a model SSA-270A (Toshiba, Japan) with 7.5-MHz linear array scanners (PLF-705S; Toshiba, Japan). Sensitivity, specificity and accuracy were 67%, 75% and 73% for cine MRI, 67%, 63% and 64% for CT, 33%, 75% and 64% for US, respectively. These results indicate that cine MRI is potentially useful for the diagnosis of chest wall invasion of lung cancer. (author)

  9. Evaluation of hepatic calcifications in cancer patients with ultrasonography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Oehl, S; Rehwald, U; Heckemann, R

    1985-02-01

    Eight patients with metastatic solid tumours had calcified liver metastases. These infiltrates can be demonstrated by plain X-ray pictures, however, they may be differentiated earlier by sonography and computed tomography. Their appearance does not necessarily correlate with the histology or response to treatment. In addition to cases of colorectal malignancy, this unusual finding occurred in association with breast cancer, thyroid and ovarian cancer.

  10. Diagnostic value of computed tomography, radiography and ultrasonography in metacarpophalangeal joint disorders in horses

    Directory of Open Access Journals (Sweden)

    V.M.V. Machado

    2016-02-01

    Full Text Available In modern society the work and athletic performance of horses has led to a very important animal production sector in which Brazil possesses the third largest horse stock. Among all equine lesions described, metacarpophalangeal (fetlock joint lesions are considered one of the main causes of lameness. Consequently, there is a need to improve the understanding and diagnosis of these injuries. The most efficient imaging diagnostic methods for the fetlock region are computed tomography, radiography and ultrasound. Imaging studies of the anatomical structures involving this joint are extremely important to obtain a more precise diagnose. The present study was performed in order to evaluate the capacity of different imaging diagnostic modalities to detect a variety of lesions in different fetlock structures. Twenty horses (Equus caballus used for horsemanship activities were referred to the Department of Animal Reproduction and Veterinary Radiology of São Paulo State University, Botucatu campus, with clinical signs of metacarpophalangeal joint injuries. Horses were submitted to radiographic and ultrasonographic exam and computed tomography scan. Image analysis revealed a significant capacity of these methods to characterize lesions in this region. However, computed tomography provided broader and better evaluation of lesions in bones and adjacent structures, because it allows the analysis to be performed on three-dimensional projections, with attenuation coefficients (window selections and tissue density measurement through Hounsfield Units (HU.

  11. Systematic review: Use of ultrasonography, computed tomography and magnetic resonance imaging for the diagnosis, assessment of activity and abdominal complications of Crohn's disease

    OpenAIRE

    Panes , Julian; Bouzas , Rosa; García-Sánchez , Valle; Chaparro , María; Pérez-Gisbert , Javier; Martínez De Guereñu , Blanca; Mendoza , Juan Luis; Paredes , José María; Quiroga , Sergi; Ripollés , Tomás; Rimola , Jordi

    2011-01-01

    Abstract Backgroud: Cross-sectional imaging techniques, including ultrasonography (US), computed tomography (CT), and magnetic resonance imaging (MRI), are increasingly used for evaluation of Crohn?s disease (CD). Aim: To perform an assessment of the diagnostic accuracy of cross-sectional imaging techniques for diagnosis of CD, evaluation of disease extension and activity, and diagnosis of complications, and to provide recommendations for their optimal use. Methods: Relevant ...

  12. EUS for the staging of gastric cancer: a meta-analysis.

    Science.gov (United States)

    Mocellin, Simone; Marchet, Alberto; Nitti, Donato

    2011-06-01

    The role of EUS in the locoregional staging of gastric carcinoma is undefined. We aimed to comprehensively review and quantitatively summarize the available evidence on the staging performance of EUS. We systematically searched the MEDLINE, Cochrane, CANCERLIT, and EMBASE databases for relevant studies published until July 2010. Formal meta-analysis of diagnostic accuracy parameters was performed by using a bivariate random-effects model. Fifty-four studies enrolling 5601 patients with gastric cancer undergoing disease staging with EUS were eligible for the meta-analysis. EUS staging accuracy across eligible studies was measured by computing overall sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR). EUS can differentiate T1-2 from T3-4 gastric cancer with high accuracy, with overall sensitivity, specificity, PLR, NLR, and DOR of 0.86 (95% CI, 0.81-0.90), 0.91 (95% CI, 0.89-0.93), 9.8 (95% CI, 7.5-12.8), 0.15 (95% CI, 0.11-0.21), and 65 (95% CI, 41-105), respectively. In contrast, the diagnostic performance of EUS for lymph node status is less reliable, with overall sensitivity, specificity, PLR, NLR, and DOR of 0.69 (95% CI, 0.63-0.74), 0.84 (95% CI, 0.81-0.88), 4.4 (95% CI, 3.6-5.4), 0.37 (95% CI, 0.32-0.44), and 12 (95% CI, 9-16), respectively. Results regarding single T categories (including T1 substages) and Bayesian nomograms to calculate posttest probabilities for any target condition prevalence are also provided. Statistical heterogeneity was generally high; unfortunately, subgroup analysis did not identify a consistent source of the heterogeneity. Our results support the use of EUS for the locoregional staging of gastric cancer, which can affect the therapeutic management of these patients. However, clinicians must be aware of the performance limits of this staging tool. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  13. Pretherapeutic evaluation of patients with upper gastrointestinal tract cancer using endoscopic and laparoscopic ultrasonography.

    Science.gov (United States)

    Mortensen, Michael Bau

    2012-12-01

    A detailed and correct pretherapeutic evaluation of stage and resectability is mandatory for an optimal treatment strategy and results in patients with cancer of the esophagus, stomach or pancreas (UGIC). Curative surgery should only be attempted in patients with limited extent of their disease, patients with locally advanced disease should be allocated for neo-adjuvant therapy, while the remaining patients should be referred for palliative measures following a quick, lenient and correct pretherapeutic evaluation. This thorough evaluation and subsequent treatment assignment is also valuable in the identification of uniform patient cohorts for new treatment protocols as well as for the continuing comparison of research data. But despite the importance of accurate pretherapeutic assessment being repeatedly emphasized insufficient staging has been - and is still accepted as - leading to high rates of explorative surgery as well as heterogeneous selection of patients for new treatment trials. Based on the results from the authors PhD thesis he concluded that endoscopic ultrasonography (EUS) as a single imaging modality provided detailed information that hitherto had been inaccessible. EUS was considered a significant progress regarding the loco-regional assessment of stage and resectability, but it was also evident that EUS alone was incapable of providing all the necessary information. In addition, there were no evidence regarding the EUS safety profile, patient tolerance of the procedure and no data on the clinical impact of both EUS and EUS guided fine-needle aspiration biopsy (EUS-FNA) in UGIC patients. Therefore, the author chose to conduct additional EUS trials and to test the use of EUS-FNA, laparoscopy (LAP), laparoscopic ultrasonography (LUS) and LUS guided biopsy in order to improve the overall pretherapeutic evaluation and thus the patient selection. The aim of this thesis was to describe the sequential development, testing and clinical results of a new

  14. Evaluation of a novel, hybrid model (Mumbai EUS II) for stepwise teaching and training in EUS-guided biliary drainage and rendezvous procedures

    Science.gov (United States)

    Dhir, Vinay; Itoi, Takao; Pausawasdi, Nonthalee; Khashab, Mouen A.; Perez-Miranda, Manuel; Sun, Siyu; Park, Do Hyun; Iwashita, Takuji; Teoh, Anthony Y. B.; Maydeo, Amit P.; Ho, Khek Yu

    2017-01-01

    Background and aims  EUS-guided biliary drainage (EUS-BD) and rendezvous (EUS-RV) are acceptable rescue options for patients with failed endoscopic retrograde cholangiopancreatography (ERCP). However, there are limited training opportunities at most centers owing to low case volumes. The existing models do not replicate the difficulties encountered during EUS-BD. We aimed to develop and validate a model for stepwise learning of EUS-BD and EUS-RV, which replicates the actual EUS-BD procedures. Methods  A hybrid model was created utilizing pig esophagus and stomach, with a synthetic duodenum and biliary system. The model was objectively assessed on a grade of 1 – 4 by two experts. Twenty-eight trainees were given initial training with didactic lectures and live procedures. This was followed by hands-on training in EUS-BD and EUS-RV on the hybrid model. Trainees were assessed for objective criteria of technical difficulties. Results  Both the experts graded the model as very good or above for all parameters. All trainees could complete the requisite steps of EUS-BD and EUS-RV in a mean time of 11 minutes (8 – 18 minutes). Thirty-six technical difficulties were noted during the training (wrong scope position, 13; incorrect duct puncture, 12; guidewire related problems, 11). Technical difficulties peaked for EUS-RV, followed by hepaticogastrostomy (HGS) and choledochoduodenostomy (CDS) (20, 9, and 7, P  = 0.001). At 10 days follow-up, nine of 28 trainees had successfully performed three EUS-RV and seven EUS-BD procedures independently. Conclusions  The Mumbai EUS II hybrid model replicates situations encountered during EUS-RV and EUS-BD. Stepwise mentoring improves the chances of success in EUS-RV and EUS-BD procedures. PMID:29250585

  15. Evaluation of a novel, hybrid model (Mumbai EUS II) for stepwise teaching and training in EUS-guided biliary drainage and rendezvous procedures.

    Science.gov (United States)

    Dhir, Vinay; Itoi, Takao; Pausawasdi, Nonthalee; Khashab, Mouen A; Perez-Miranda, Manuel; Sun, Siyu; Park, Do Hyun; Iwashita, Takuji; Teoh, Anthony Y B; Maydeo, Amit P; Ho, Khek Yu

    2017-11-01

    EUS-guided biliary drainage (EUS-BD) and rendezvous (EUS-RV) are acceptable rescue options for patients with failed endoscopic retrograde cholangiopancreatography (ERCP). However, there are limited training opportunities at most centers owing to low case volumes. The existing models do not replicate the difficulties encountered during EUS-BD. We aimed to develop and validate a model for stepwise learning of EUS-BD and EUS-RV, which replicates the actual EUS-BD procedures.  A hybrid model was created utilizing pig esophagus and stomach, with a synthetic duodenum and biliary system. The model was objectively assessed on a grade of 1 - 4 by two experts. Twenty-eight trainees were given initial training with didactic lectures and live procedures. This was followed by hands-on training in EUS-BD and EUS-RV on the hybrid model. Trainees were assessed for objective criteria of technical difficulties.  Both the experts graded the model as very good or above for all parameters. All trainees could complete the requisite steps of EUS-BD and EUS-RV in a mean time of 11 minutes (8 - 18 minutes). Thirty-six technical difficulties were noted during the training (wrong scope position, 13; incorrect duct puncture, 12; guidewire related problems, 11). Technical difficulties peaked for EUS-RV, followed by hepaticogastrostomy (HGS) and choledochoduodenostomy (CDS) (20, 9, and 7, P  = 0.001). At 10 days follow-up, nine of 28 trainees had successfully performed three EUS-RV and seven EUS-BD procedures independently.  The Mumbai EUS II hybrid model replicates situations encountered during EUS-RV and EUS-BD. Stepwise mentoring improves the chances of success in EUS-RV and EUS-BD procedures.

  16. Detection Efficiency of Microcalcification using Computer Aided Diagnosis in the Breast Ultrasonography Images

    International Nuclear Information System (INIS)

    Lee, Jin Soo; Ko, Seong Jin; Kang, Se Sik; Kim, Jung Hoon; Choi, Seok Yoon; Kim, Chang Soo; Park, Hyung Hu

    2012-01-01

    Digital Mammography makes it possible to reproduce the entire breast image. And it is used to detect microcalcification and mass which are the most important point of view of nonpalpable early breast cancer, so it has been used as the primary screening test of breast disease. It is reported that microcalcification of breast lesion is important in diagnosis of early breast cancer. In this study, six types of texture features algorithms are used to detect microcalcification on breast US images and the study has analyzed recognition rate of lesion between normal US images and other US images which microcalification is seen. As a result of the experiment, Computer aided diagnosis recognition rate that distinguishes mammography and breast US disease was considerably high 70-98%. The average contrast and entropy parameters were low in ROC analysis, but sensitivity and specificity of four types parameters were over 90%. Therefore it is possible to detect microcalcification on US images. If not only six types of texture features algorithms but also the research of additional parameter algorithm is being continually proceeded and basis of practical use on CAD is being prepared, it can be a important meaning as pre-reading. Also, it is considered very useful things for early diagnosis of breast cancer.

  17. Agreement between ultrasonography and computed tomography in detecting intracranial calcifications in congenital toxoplasmosis

    Energy Technology Data Exchange (ETDEWEB)

    Lago, E.G. [Department of Pediatrics, Pontificia Universidade Catolica do Rio Grande do Sul School of Medicine, Sao Lucas Hospital, Porto Alegre (Brazil)], E-mail: eglago@pucrs.br; Baldisserotto, M.; Hoefel Filho, J.R.; Santiago, D. [Department of Radiology, Pontificia Universidade Catolica do Rio Grande do Sul School of Medicine, Sao Lucas Hospital, Porto Alegre (Brazil); Jungblut, R. [Department of Pediatrics, Pontificia Universidade Catolica do Rio Grande do Sul School of Medicine, Sao Lucas Hospital, Porto Alegre (Brazil)

    2007-10-15

    Aim: To evaluate the agreement between ultrasound (US) and computed tomography (CT) in detecting intracranial calcification in infants with congenital toxoplasmosis. Materials and methods: Forty-four infants referred for investigation of congenital toxoplasmosis were prospectively evaluated, and the diagnosis was confirmed or ruled out by serological testing and by follow-up in the first year of life. The investigation protocol included cranial US and cranial CT, and examinations were conducted and interpreted by two radiologists blinded to the results of the other imaging test and to the diagnostic confirmation. Results: The diagnosis of congenital toxoplasmosis was confirmed in 33 patients, and agreement between US and CT findings was found in 31 of these cases. Both methods detected calcifications in 18 patients, and neither detected calcifications in 13 patients. Overall agreement was 94% and the kappa coefficient was 0.88 (95% confidence interval: 0.71, 1; p < 0.001), which revealed almost perfect agreement between the two diagnostic methods. Conclusion: In this study, US and CT demonstrated equal sensitivity in the detection of intracranial calcification in infants with congenital toxoplasmosis.

  18. The contribution of ultrasonography and computed tomography in the evaluation of abdominal involvement in paracoccidioidomycosis

    Energy Technology Data Exchange (ETDEWEB)

    Paula, Ivie Braga de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Radiologia; Pedroso, Enio Roberto Pietra; Ferreira, Cid Sergio, E-mail: enio@medicina.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Fac. de Medicina

    2014-01-15

    Introduction: paracoccidioidomycosis (PCM) is a polymorphic systemic granulomatous inflammatory disease determined by Paracoccidioides brasiliensis, one of the 10 leading causes of morbidity and mortality among the parasitic diseases endemic in Brazil. Objective: To identify the following aspects of PCM by ultrasound (US) and computed tomography (CT): abdominal changes, intensity and characteristics of the observed images, frequency of changes depending on clinical presentation, differences from other nosological entities. Patients and methods: This was a retrospective, observational, cross-sectional study carried out with 35 patients with PCM treated at the Hospital das Clinicas (HC) at the Universidade Federal de Minas Gerais (UFMG). Patients with tuberculosis, bronchial asthma, generalized chronic obstructive pulmonary disease, or in contact with silica or mines, as well as those with granulomatous diseases at any point in their current or past clinical history and detected through serology, anatomopathology or microbiological exams were excluded. Collected data were transcribed into SPSS for Windows® for statistical analysis. The study was approved by the UFMG Ethics Committee (082/00). Results and conclusion: CT and U.S. showed involvement of abdominal organs in all forms of PCM, including lymphadenopathy (40%), hepatomegaly (37%), splenomegaly (37%) and adrenal involvement (17%). Gallbladder and retroperitoneal musculature involvement were also observed, along with ascites and pleural effusion. Lymph node calcification, adrenal involvement and ascites constituted evidence of high probability of PCM even though these findings are not enough to differentiate PCM from tuberculosis. Chronic and sequelae forms, abdominal involvement is more frequent than indicated by the clinical manifestations. (author)

  19. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer

    DEFF Research Database (Denmark)

    Konge, Lars; Vilmann, P; Clementsen, P

    2012-01-01

    Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was to explore the reliabilit...... and validity of a newly developed EUS Assessment Tool (EUSAT) designed to measure competence in EUS - FNA for mediastinal staging of NSCLC....

  20. Transabdominal ultrasonography, computed tomography and electronic portal imaging for 3-dimensional conformal radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Jereczek-Fossa, B.A.; Orecchia, R.; Cattani, F.; Garibaldi, C.; Cambria, R.; Valenti, M.; Ciocca, M.; Zerini, D.; Boboc, G.I.; Vavassori, A.; Ivaldi, G.B.; Kowalczyk, A.; Matei, D.V.; Cobelli, O. de

    2007-01-01

    Purpose: To evaluate the feasibility and accuracy of daily B-mode acquisition and targeting ultrasound-based prostate localization (BAT trademark) and to compare it with computed tomography (CT) and electronic portal imaging (EPI) in 3-dimensional conformal radiotherapy (3-D CRT) for prostate cancer. Patients and Methods: Ten patients were treated with 3-D CRT (72 Gy/30 fractions, 2.4 Gy/fraction, equivalent to 80 Gy/40 fractions, for α/β ratio of 1.5 Gy) and daily BAT-based prostate localization. For the first 5 fractions, CT and EPI were also performed in order to compare organ-motion and set-up error, respectively. Results: 287 BAT-, 50 CT- and 46 EPI-alignments were performed. The average BAT-determined misalignments in latero-lateral, antero-posterior and cranio-caudal directions were -0.9 mm ± 3.3 mm, 1.0 mm ± 4.0 mm and -0.9 mm ± 3.8 mm, respectively. The differences between BAT- and CT-determined organ-motion in latero-lateral, antero-posterior and cranio-caudal directions were 2.7 mm ± 1.9 mm, 3.9 ± 2.8 mm and 3.4 ± 3.0 mm, respectively. Weak correlation was found between BAT- and CT-determined misalignments in antero-posterior direction, while no correlation was observed in latero-lateral and cranio-caudal directions. The correlation was more significant when only data of good image-quality patients were analyzed (8 patients). Conclusion: BAT ensures the relative positions of target are the same during treatment and in treatment plan, however, the reliability of alignment is patient-dependent. The average BAT-determined misalignments were small, confirming the prevalence of random errors in 3-D CRT. Further study is warranted in order to establish the clinical value of BAT. (orig.)

  1. The use of computed tomographic three-dimensional reconstructions to develop instructional models for equine pelvic ultrasonography.

    Science.gov (United States)

    Whitcomb, Mary Beth; Doval, John; Peters, Jason

    2011-01-01

    Ultrasonography has gained increased utility to diagnose pelvic fractures in horses; however, internal pelvic contours can be difficult to appreciate from external palpable landmarks. We developed three-dimensional (3D) simulations of the pelvic ultrasonographic examination to assist with translation of pelvic contours into two-dimensional (2D) images. Contiguous 1mm transverse computed tomography (CT) images were acquired through an equine femur and hemipelvis using a single slice helical scanner. 3D surface models were created using a DICOM reader and imported into a 3D modeling and animation program. The bone models were combined with a purchased 3D horse model and the skin made translucent to visualize pelvic surface contours. 3D models of ultrasound transducers were made from reference photos, and a thin sector shape was created to depict the ultrasound beam. Ultrasonographic examinations were simulated by moving transducers on the skin surface and rectally to produce images of pelvic structures. Camera angles were manipulated to best illustrate the transducer-beam-bone interface. Fractures were created in multiple configurations. Animations were exported as QuickTime movie files for use in presentations coupled with corresponding ultrasound videoclips. 3D models provide a link between ultrasonographic technique and image generation by depicting the interaction of the transducer, ultrasound beam, and structure of interest. The horse model was important to facilitate understanding of the location of pelvic structures relative to the skin surface. While CT acquisition time was brief, manipulation within the 3D software program was time intensive. Results were worthwhile from an instructional standpoint based on user feedback. © 2011 Veterinary Radiology & Ultrasound.

  2. Computer-aided detection system for masses in automated whole breast ultrasonography: development and evaluation of the effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeoung Hyun [Dept. of Radiology, Ewha Womans University Mokdong Hospital, Ewha Womans University School of Medicine, Seoul (Korea, Republic of); Cha, Joo Hee; Kim, Nam Kug; Chang, Young Jun; Kim, Hak Hee [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Ko, Myung Su [Health Screening and Promotion Center, Asan Medical Center, Seoul (Korea, Republic of); Choi, Young Wook [Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2014-04-15

    The aim of this study was to evaluate the performance of a proposed computer-aided detection (CAD) system in automated breast ultrasonography (ABUS). Eighty-nine two-dimensional images (20 cysts, 42 benign lesions, and 27 malignant lesions) were obtained from 47 patients who underwent ABUS (ACUSON S2000). After boundary detection and removal, we detected mass candidates by using the proposed adjusted Otsu's threshold; the threshold was adaptive to the variations of pixel intensities in an image. Then, the detected candidates were segmented. Features of the segmented objects were extracted and used for training/testing in the classification. In our study, a support vector machine classifier was adopted. Eighteen features were used to determine whether the candidates were true lesions or not. A five-fold cross validation was repeated 20 times for the performance evaluation. The sensitivity and the false positive rate per image were calculated, and the classification accuracy was evaluated for each feature. In the classification step, the sensitivity of the proposed CAD system was 82.67% (SD, 0.02%). The false positive rate was 0.26 per image. In the detection/segmentation step, the sensitivities for benign and malignant mass detection were 90.47% (38/42) and 92.59% (25/27), respectively. In the five-fold cross-validation, the standard deviation of pixel intensities for the mass candidates was the most frequently selected feature, followed by the vertical position of the centroids. In the univariate analysis, each feature had 50% or higher accuracy. The proposed CAD system can be used for lesion detection in ABUS and may be useful in improving the screening efficiency.

  3. Diagnostic performance of fluorodeoxyglucose-positron emission tomography/computed tomography of breast cancer in detecting axillary lymph node metastasis. Comparison with ultrasonography and contrast-enhanced CT

    International Nuclear Information System (INIS)

    Monzawa, Shuichi; Adachi, Shuji; Suzuki, Kayo; Hirokaga, Koichi; Takao, Shintaro; Sakuma, Toshiko; Hanioka, Keisuke

    2009-01-01

    The purpose of this retrospective study was to evaluate the diagnostic performance of positron emission tomography/computed tomography (PET/CT) with fluorine-18-labeled 2-fluoro-2-deoxy-D-glucose (FDG) in comparison with that of ultrasonography and contrast-enhanced computed tomography (CT) in detecting axillary lymph node metastasis in patients with breast cancer. Fifty patients with invasive breast cancer were recruited. They had received no neoadjuvant chemotherapy and underwent PET/CT, ultrasonography and contrast-enhanced CT before mastectomy. The clinical stage was I in 34 patients, II in 15 patients, and III in one patient. The images of these modalities were interpreted in usual practice before surgery and the diagnostic reports were reviewed for analysis. Sensitivity, specificity, positive predictive value, and negative predictive value of each modality were obtained taking histopathological results of axillary lymph node dissection or sentinel lymph node biopsy as the reference standard. Axillary lymph node metastasis was confirmed in 15 of 50 patients by histopathological studies. PET/CT identified lymph node metastasis in three of these 15 patients. The overall sensitivity and specificity, positive predictive value, and negative predictive value of PET/CT in the diagnosis of axillary lymph node metastasis were 20, 97, 75, and 74%, and those of ultrasonography were 33, 94, 71, and 77% and those of contrast-enhanced CT were 27, 97, 80, and 76%, respectively. PET/CT showed poor sensitivity and high specificity in the detection of axillary lymph node metastasis of breast cancer. Diagnostic performance of PET/CT was not superior to that of ultrasonography and contrast-enhanced CT. (author)

  4. Comparison of contrast media for visualization of the colon of healthy dogs during computed tomography and ultrasonography.

    Science.gov (United States)

    Cheon, Byunggyu; Moon, Sohyeon; Park, Seungjo; Lee, Sang-Kwon; Hong, Sunghwa; Cho, Hyun; Choi, Jihye

    2016-11-01

    OBJECTIVE To evaluate contrast agents for their ability to improve visualization of the colon wall and lumen during CT and ultrasonography. ANIMALS 10 healthy adult Beagles. PROCEDURES Food was withheld from dogs for 36 hours, after which dogs consumed 250 mL of polyethylene glycol solution. Dogs were then anesthetized, a contrast agent (tap water, diluted barium, or air; order randomly assigned) was administered rectally, iodine contrast medium (880 mg of I/kg) was administered IV, and CT and ultrasonography of the colon were performed. After a 1-week washout period, this process was repeated with a different contrast agent until all agents had been evaluated. Two investigators reviewed the CT and ultrasonographic images for colon wall thickness, conspicuity, artifacts, wall layering, and degree of lumen dilation at 4 sites. RESULTS Thickness of the colon wall was greatest in CT and ultrasonographic images with water used as contrast agent, followed by barium and then air. The CT images obtained after water administration had a smooth appearance that outlined the colonic mucosa and had the highest score of the 3 contrast agents for wall conspicuity. Although no substantial artifacts related to any of the contrast agents were identified on CT images, barium- and gas-induced shadowing and reverberation artifacts hindered wall evaluation during ultrasonography. For ultrasonography, the degree of conspicuity was highest with barium in the near-field wall and with water in the far-field wall. In contrast to CT, ultrasonography could be used to distinguish wall layering, and the mucosal and muscular layers were distinct with all contrast agents. CONCLUSIONS AND CLINICAL RELEVANCE Use of water as a contrast agent for both CT and ultrasonography of the colon in dogs compensated for each imaging modality's disadvantages and could be beneficial in the diagnosis of colon disease.

  5. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, J-M; Polkowski, M; Larghi, A

    2011-01-01

    This article is part of a combined publication that expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about endoscopic ultrasound (EUS)-guided sampling in gastroenterology, including EUS-guided fine needle aspiration (EUS-FNA) and EUS-guided trucut biopsy (EU...

  6. Comparison of ultrasonography and computed tomography in the diagnosis of acute appendicitis; Comparacion de la ecografia y la tomografia computarizada en el diagnostico de la apendicitis aguda

    Energy Technology Data Exchange (ETDEWEB)

    Cura, J. L. del; Oleaga, L.; Grande, D.; Farina, M. A.; Isusi, M. [Hospital de Basurto. Bilbao (Spain)

    2001-07-01

    The compare the efficacy of ultrasonography and computed tomography (CT) in cases of suspected appendicitis. To study to what extent age, sex and habits of the patients, as well as the clinical context, influence the diagnostic yield of these two technique. Over a one-year period, 152 patients underwent ultrasonography and CT because of the clinical suspicion of appendicitis. The studies were carried out independently, and the results of each in terms of the presence or absence of appendicitis were unknown to the specialists performing the other. The final diagnoses were established by surgical treatment or clinical follow-up. The sensitivity of CT for the diagnosis of appendicitis was 82%, the specificity was 95%, the positive predictive value was 93%, the negative predictive value was 87% and the reliability was 90%. Ultrasonography has a sensitivity of 83%, a specificity of 97%, a positive predictive value of 95%, a negative predictive value of 88% and a reliability of 91%. Ultrasound was more efficient in patients in which there was a high clinical suspicion and in children, while the results with CT were better in patients in which the clinical diagnosis was less clear. The incidence of false negatives and positives was higher with ultrasound, while CT was more frequently able to identify a normal appendix. Sex and habits had no influence on the respective efficacies, although the performance of ultrasound was simplified in thin patients and that of CT in obese individuals. Ultrasonography and CT are highly reliable in cases of suspected appendicitis, especially when this diagnosis is conformed. Ultrasound is recommended as the technique of choice in children and in patients in which the clinical suspicion is strong. The yield of CT is somewhat greater when the clinical signs and symptoms are less clear. However, the efficacy of both techniques ultimately depends on the expertise of the specialist who interprets them. (Author) 62 refs.

  7. EUS-Guided Needle-Based Confocal Laser Endomicroscopy

    DEFF Research Database (Denmark)

    Bhutani, Manoop S; Koduru, Pramoda; Joshi, Virendra

    2015-01-01

    Endoscopic ultrasound (EUS) has emerged as an excellent tool for imaging the gastrointestinal tract, as well as surrounding structures. EUS-guided fine-needle aspiration (EUS-FNA) has become the standard of care for the tissue sampling of a variety of masses and lymph nodes within and around...... the gut, providing further diagnostic and staging information. Confocal laser endomicroscopy (CLE) is a novel endoscopic method that enables imaging at a subcellular level of resolution during endoscopy, allowing up to 1000-fold magnification of tissue and providing an optical biopsy. A new procedure...... that has been developed in the past few years is needle-based confocal laser endomicroscopy (nCLE), which involves a mini-CLE probe that can be passed through a 1 9-gauge needle during EUS-FNA. This enables the real-time visualization of tissue at a microscopic level, with the potential to further improve...

  8. Diagnostic performance of combined single photon emission computed tomographic scintimammography and ultrasonography based on computer-aided diagnosis for breast cancer

    International Nuclear Information System (INIS)

    Hwang, Kyung Hoon; Choi, Duck Joo; Choe, Won Sick; Lee, Jun Gu; Kim, Jong Hyo; Lee, Hyung Ji; Om, Kyong Sik; Lee, Byeong Il

    2007-01-01

    We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors.) The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve=0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve=0.860), but there was no statistical difference in sensitivity, specificity and accuracy between the combined method and a single modality. It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer

  9. Influence of tumor characteristics on the accuracy of endoscopic ultrasonography in staging cancer of the esophagus and esophagogastric junction

    NARCIS (Netherlands)

    Heeren, PAM; van Westreenen, HL; Geersing, GJ; van Dullemen, HM; Plukker, JTM

    Background and Study Aims: Endoscopic ultrasonography (EUS) is the most accurate method of assessing the locoregional extent of cancer of the esophagus and esophagogastric junction. The aim of this study was to evaluate the influence of tumor-related factors such as length and location on the

  10. Influence of tumor characteristics on the accuracy of endoscopic ultrasonography in staging cancer of the esophagus and esophagogastric junction

    NARCIS (Netherlands)

    Heeren, PAM; van Westreenen, HL; Geersing, GJ; van Dullemen, HM; Plukker, JTM

    2004-01-01

    Background and Study Aims: Endoscopic ultrasonography (EUS) is the most accurate method of assessing the locoregional extent of cancer of the esophagus and esophagogastric junction. The aim of this study was to evaluate the influence of tumor-related factors such as length and location on the

  11. [Pancreatic ultrasonography].

    Science.gov (United States)

    Fernández-Rodríguez, T; Segura-Grau, A; Rodríguez-Lorenzo, A; Segura-Cabral, J M

    2015-04-01

    Despite the recent technological advances in imaging, abdominal ultrasonography continues to be the first diagnostic test indicated in patients with a suspicion of pancreatic disease, due to its safety, accessibility and low cost. It is an essential technique in the study of inflammatory processes, since it not only assesses changes in pancreatic parenchyma, but also gives an indication of the origin (bile or alcoholic). It is also essential in the detection and tracing of possible complications as well as being used as a guide in diagnostic and therapeutic punctures. It is also the first technique used in the study of pancreatic tumors, detecting them with a sensitivity of around 70% and a specificity of 90%. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  12. EUS-guided biliary rendezvous using a short hydrophilic guidewire.

    Science.gov (United States)

    Dhir, Vinay; Kwek, Boon Eu Andrew; Bhandari, Suryaprakash; Bapat, Mukta; Maydeo, Amit

    2011-10-01

    BACKGROUND AND STUDY AIMS: EUS-guided rendezvous technique for biliary access requires expert manipulation of the guidewire across the downstream stricture or papilla. Published literature reports usage of the long-wire system to prevent loss of wire during scope exchange. We studied the efficacy of using a short hydrophilic guidewire in EUS-guided rendezvous. PATIENTS AND METHODS: This is a retrospective study conducted in a tertiary care referral centre. 15 patients underwent EUS-guided biliary rendezvous with short wire. EUS-guided transduodenal/transgastric puncture of the biliary system was performed, followed by anterograde placement of a hydrophilic short-wire (260 cm) across the downstream stricture and/or papilla. Retrograde access was then achieved by retrieving the trans-papillary wire, followed by standard ERCP intervention. Main outcome measurements were rates of procedural success and complications. RESULTS: EUS-guided biliary rendezvous was successful in 14 patients (93.3%). Failure was seen in one patient due to a tight malignant biliary stricture. One patient had peri-choledochal bile tracking which did not require any specific treatment. CONCLUSIONS: Short-wire system in EUS-guided biliary rendezvous is highly effective and safe. It is a useful salvage procedure for biliary cannulation in patients with accessible papilla.

  13. Clinical usefulness of endoscopic ultrasonography for the evaluation of ulcerative colitis-associated tumors

    Science.gov (United States)

    Kobayashi, Kiyonori; Kawagishi, Kana; Ooka, Shouhei; Yokoyama, Kaoru; Sada, Miwa; Koizumi, Wasaburo

    2015-01-01

    AIM: To evaluate the clinical usefulness of endoscopic ultrasonography (EUS) for the diagnosis of the invasion depth of ulcerative colitis-associated tumors. METHODS: The study group comprised 13 patients with 16 ulcerative colitis (UC)-associated tumors for which the depth of invasion was preoperatively estimated by EUS. The lesions were then resected endoscopically or by surgical colectomy and were examined histopathologically. The mean age of the subjects was 48.2 ± 17.1 years, and the mean duration of UC was 15.8 ± 8.3 years. Two lesions were treated by endoscopic resection and the other 14 lesions by surgical colectomy. The depth of invasion of UC-associated tumors was estimated by EUS using an ultrasonic probe and was evaluated on the basis of the deepest layer with narrowing or rupture of the colonic wall. RESULTS: The diagnosis of UC-associated tumors by EUS was carcinoma for 13 lesions and dysplasia for 3 lesions. The invasion depth of the carcinomas was intramucosal for 8 lesions, submucosal for 2, the muscularis propria for 2, and subserosal for 1. Eleven (69%) of the 16 lesions arose in the rectum. The macroscopic appearance was the laterally spreading tumor-non-granular type for 4 lesions, sessile type for 4, laterally spreading tumor-granular type for 3, semi-pedunculated type (Isp) for 2, type 1 for 2, and type 3 for 1. The depth of invasion was correctly estimated by EUS for 15 lesions (94%) but was misdiagnosed as intramucosal for 1 carcinoma with high-grade submucosal invasion. The 2 lesions treated by endoscopic resection were intramucosal carcinoma and dysplasia, and both were diagnosed as intramucosal lesions by EUS. CONCLUSION: EUS provides a good estimation of the invasion depth of UC-associated tumors and may thus facilitate the selection of treatment. PMID:25759538

  14. Sensitivity and Specificity of Magnetic Resonance Cholangiopancreatography versus Endoscopic Ultrasonography against Endoscopic Retrograde Cholangiopancreatography in Diagnosing Choledocholithiasis: The Indonesian Experience

    Directory of Open Access Journals (Sweden)

    Dadang Makmun

    2017-09-01

    Full Text Available Background/Aims Biliary stone disease is one of the most common conditions leading to hospitalization. In addition to endoscopic retrograde cholangiopancreatography (ERCP, endoscopic ultrasonography (EUS and magnetic resonance cholangiopancreatography (MRCP are required in diagnosing choledocholithiasis. This study aimed to compare the sensitivity and specificity of EUS and MRCP against ERCP in diagnosing choledocholithiasis. Methods This retrospective study was conducted after prospective collection of data involving 62 suspected choledocholithiasis patients who underwent ERCP from June 2013 to August 2014. Patients were divided into two groups. The first group (31 patients underwent EUS and the second group (31 patients underwent MRCP. Then, ERCP was performed in both groups. Sensitivity, specificity, and diagnostic accuracy of EUS and MRCP were determined by comparing them to ERCP, which is the gold standard. Results The male to female ratio was 3:2. The mean ages were 47.25 years in the first group and 52.9 years in the second group. Sensitivity, specificity, accuracy, positive predictive value, and negative predictive value for EUS were 96%, 57%, 87%, 88%, and 80% respectively, and for MRCP were 81%, 40%, 68%, 74%, and 50%, respectively. Conclusions EUS is a better diagnostic tool than MRCP for diagnosing choledocholithiasis.

  15. The role of multi-detector-row computed tomograph in the diagnosis of intraductal papillary-mucinous tumors of the pancreas in comparison to endoscopic retrograde pancreatography, endoscopic ultrasonography, magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Arikawa, Shunji; Uchida, Masafumi; Shinagawa, Masaharu

    2007-01-01

    Thirty patients with intraductal papillary-mucinous tumor (IPMT) of the pancreas underwent multidetector-row CT (MD-CT) in addition to endoscopic retrograde pancreatography (ERP), and, in 27 cases magnetic resonance cholangiopancreatography (MRCP) and endoscopic ultrasonography (EUS). The usefulness of MD-CT was investigated by comparing various imaging methods of the communication from the main pancreatic duct (MPD) to patulous/bulging papilla in addition to the indices for benign or malignant disease, the degree of dilation of the MPD, localization and size of cystic lesions, and presence or absence of neoplastic lesions, such as thickened walls and septa, intramural nodule, solid mass. With MD-CT, dilation of the MPD and localization and size of cystic lesions were accurately assessed, even in patients with obstruction of the main pancreatic duct in whom ERP was difficult to perform regardless of the presence or absence of massive amount of mucus. MD-CT with reconstructive imaging, such as multiplanar reformation (MPR) imaging and curred planar reformation (CPR) imaging, allowed us to assess communication with the MPD and patulous/bulging papilla easier than MRCP. In our study, MD-CT was useful in the evaluation of thickened walls and septa that are predictive factors of malignancy in IPMT. (author)

  16. Search for Spin Filtering By Electron Tunneling Through Ferromagnetic EuS Barriers in Pbs

    Science.gov (United States)

    Figielski, T.; Morawski, A.; Wosinski, T.; Wrotek, S.; Makosa, A.; Lusakowska, E.; Story, T.; Sipatov, A. Yu.; Szczerbakow, A.; Grasza, K.; hide

    2002-01-01

    Perpendicular transport through single- and double-barrier heterostructures consisting of ferromagnetic EuS layers embedded into PbS matrix was investigated. Manifestations of both resonant tunneling and spin filtering through EuS barrier have been observed.

  17. Impact of EUS-guided FNA on management of gastric carcinoma

    DEFF Research Database (Denmark)

    Hassan, Hazem; Vilmann, Peter; Sharma, Vijay

    2010-01-01

    EUS is an integral part of the pretherapeutic evaluation program for patients with upper GI cancer.......EUS is an integral part of the pretherapeutic evaluation program for patients with upper GI cancer....

  18. A comparative study to validate the use of ultrasonography and computed tomography in patients with post-operative intra-abdominal sepsis

    International Nuclear Information System (INIS)

    Go, H.L.S.; Baarslag, H.J.; Vermeulen, H.; Lameris, J.S.; Legemate, D.A.

    2005-01-01

    Purpose: To validate abdominal ultrasonography and helical computed tomography in detecting causes for sepsis in patients after abdominal surgery and to determine improved criteria for its use. Materials and methods: Eighty-five consecutive surgical patients primarily operated for non-infectious disease were included in this prospective study. Forty-one patients were admitted to the intensive care unit. All patients were suspected of an intra-abdominal sepsis after abdominal surgery. Both ultrasonography (US) and helical abdominal computed tomography (CT) were performed to investigate the origin of an intra-abdominal sepsis. The images of both US and CT were interpreted on a four-point scale by different radiologists or residents in radiology, the investigators were blinded of each other's test. Interpretations of US and CT were compared with a reference standard which was defined by the result of diagnostic aspiration of suspected fluid collections (re)laparotomy, clinical course or the opinion of an independent panel. Likelihood ratios and post-test probabilities were calculated and interobserver agreement was determined using κ statistics. Results: The overall prevalence of an abdominal infection was 0.49. The likelihood ratio (LR) of a positive test-result for US was 1.33 (95% CI: 0.8-2.5) and for CT scan 2.53 (95% CI: 1.4-5.0); corresponding post-test probabilities for US 0.57 (95% CI: 0.42-0.70) and for CT 0.71 (95% CI: 0.57-0.83). The LR of a negative test-result was, respectively, 0.60 (95% CI: 0.3-1.3) and 0.18 (95% CI: 0.06-0.5); corresponding post-test probabilities for US 0.37 (95% CI: 0.20-0.57) and for CT 0.15 (95% CI: 0.06-0.32) were calculated. Conclusion: Computed tomography can be used as the imaging modality of choice in patients suspected of intra-abdominal sepsis after abdominal surgery. Because of the low discriminatory power ultrasonography should not be performed as initial diagnostic test

  19. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer

    NARCIS (Netherlands)

    Konge, L.; Vilmann, P.; Clementsen, P.; Annema, J. T.; Ringsted, C.

    2012-01-01

    Background and study aims: Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was

  20. Contrast-Enhanced Endoscopic Ultrasonography for Pancreatic Tumors

    Directory of Open Access Journals (Sweden)

    Yasunobu Yamashita

    2015-01-01

    Full Text Available Objectives. To investigate the usefulness of contrast-enhanced endoscopic ultrasonography (CE-EUS for histological differentiation of pancreatic tumors. Methods. CE-EUS was performed for consecutive patients having a pancreatic solid lesion, and tumors were classified into three vascular patterns (hypervascular, isovascular, and hypovascular at two time phases (early-phase and late-phase. Correlation between vascular patterns and histopathology of resected pancreatic cancer (PC tissues was ascertained. Results. The final diagnoses of 147 examined tumors were PC (n=109, inflammatory mass (n=11, autoimmune pancreatitis (n=9, neuroendocrine tumor (n=8, and others (n=10. In late-phase images, 104 of 109 PCs had the hypovascular pattern, for a diagnostic sensitivity and specificity of 94% and 71%, respectively. Of 28 resected PCs, 10 had isovascular, and 18 hypovascular, patterns on the early-phase image. Early-phase isovascular PCs were more likely to be differentiated than were early-phase hypovascular PCs (6 well and 4 moderately differentiated versus 3 well, 14 moderately, and 1 poorly differentiated, P=0.028. Immunostaining revealed that hypovascular areas of early-phase images reflected heterogeneous tumor cells with fibrous tissue, necrosis, and few vessels. Conclusion. CE-EUS could be useful for distinguishing PC from other solid pancreatic lesions and for histological differentiation of PCs.

  1. EUS-Guided Vascular Procedures: A Literature Review

    Directory of Open Access Journals (Sweden)

    Tomislav Bokun

    2013-01-01

    Full Text Available Endoscopic ultrasound (EUS is continuously stepping into the therapeutic arena, simultaneously evolving in different directions, such as the management of pancreatic and biliary diseases, celiac neurolysis, delivering local intratumoral therapy, and EUS-guided endosurgery. EUS-guided vascular procedures are also challenging, considering the variety of vascular pathology, proximity of the vascular structures to the GI tract wall, high resolution, and real-time guidance offering an attractive access route and precise delivery of the intervention. The literature on vascular therapeutic EUS demonstrates techniques for the management of upper GI variceal and nonvariceal bleeding, pseudoaneurysms, and coiling and embolization procedures, as well as the creation of intrahepatic portosystemic shunts. The paucity of studies, diversity of study designs, and the number of animal model studies hamper a systematic approach to the conclusion and decision making important to clinicians and healthcare policy makers. Nevertheless, theoretical benefits and findings up to date concerning technical feasibility, efficacy, and safety of the procedures drive further research and development in this rather young therapeutic arena.

  2. EUS needle identification comparison and evaluation (NICE) study (with videos)

    Science.gov (United States)

    Tang, Shou-jiang; Vilmann, Andreas S.; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin; Fink, Peter P.; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F.; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T.; van der Heijden, Erik H.F.M.; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H.; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R.; Lee, Linda S.; Aslanian, Harry R.; Wang, Andrew Y.; Shami, Vanessa M.; Markowitz, Arnold; Siddiqui, Ali A.; Mishra, Girish; Scheiman, James M.; Isenberg, Gerard; Siddiqui, Uzma D.; Shah, Raj J.; Buxbaum, James; Watson, Rabindra R.; Willingham, Field F.; Bhutani, Manoop S.; Levy, Michael J.; Harris, Cynthia; Wallace, Michael B.; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D’Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S.; Freeman, Simon; McCowan, Timothy C.; de Araujo, Cyrillo Rodrigues; Patel, Akash; del Ali, Mohammad A; Campbell, Garth; Chen, Edward; Vilmann, Peter

    2017-01-01

    Background and Aims Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) or biopsy is widely practiced. Optimal sonographic visualization of the needle is critical for image guided interventions. There are several commercially available needles but no bench-top testing and direct comparison of these needles to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Methods Descriptive bench-top testing and comparison. Bench-top testing of 8 commonly used EUS-FNA needles (all of 22 gauge in size): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition, (Cook Medical); ClearView (Conmed); EZ Shot2 (Olympus); BNX (Beacon Endoscopic); and 2 new prototype needles that are coated by echogenic polymers by Medi-Globe. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in gastrointestinal ultrasound examination that is unfamiliar with EUS needle devices. Results There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, one prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (p<0.01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%–75% worse, p<0.001). Conclusions All FNA needles have their inherent and different echogenicity, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. PMID:26873530

  3. Hepatobiliary ultrasonography

    Science.gov (United States)

    Sembiring, J.

    2018-03-01

    Ultrasound is one of the most widely used imaging technologies in medicine. It is portable, free of radiation risk, non-invasive and relatively inexpensive when compared with other imaging modalities, such as magnetic resonance and computed tomography. Ultrasound is a useful procedure for evaluating many structures organ in our body. An examination may include the entirety of the abdomen and retroperitoneum from a single organ to several organs. An abdominal ultrasound examination survey would include the liver, gallbladder, biliary tree, pancreas, spleen, kidneys and retroperitoneal structures. It needsperforming when there is a valid medical reason.

  4. Non-real-time computed tomography-guided percutaneous ethanol injection therapy for heapocellular carcinoma undetectable by ultrasonography

    International Nuclear Information System (INIS)

    Ueda, Kazushige; Ohkawara, Tohru; Minami, Masahito; Sawa, Yoshihiko; Morinaga, Osamu; Kohli, Yoshihiro; Ohkawara, Yasuo

    1998-01-01

    The purpose of this study was to evaluate the feasibility of non-real-time CT-guided percutaneous ethanol injection therapy (PEIT) for hepatocellular carcinoma (HCC, 37 lesions) untreatable by ultrasonography-guided (US)-PEIT. The HCC lesion was localized on the lipiodol CT image with a graduated grid system. We advanced a 21 G or 22 G needle in a stepwise fashion with intermittent localization scans using a tandem method to position the tip of the needle in the lesion. Ethanol containing contrast medium was injected with monitoring scans obtained after incremental volumes of injection, until perfusion of the lesion was judged to be complete. A total of 44 CT-PEIT procedures were performed. The average number of needle passes from the skin to the liver in each CT-PEIT procedure was 2.3, the average amount of ethanol injected was 14.4 ml, and the average time required was 49.3 minutes. Complete perfusion of the lesion by ethanol on monitoring CT images was achieved in all lesions with only a single or double CT-PEIT procedure without severe complication. Local recurrence was detected only in 5 lesions. At present, it is more time-consuming to perform CT-PEIT than US-PEIT because conventional CT guidance is not real-time imaging. However, it is expected that this limitation of CT-PEIT will be overcome in the near future with the introduction of CT fluoroscopy. In conclusion, CT-PEIT should prove to be a feasible, acceptable treatment for challenging cases of HCC undetectable by US. (author)

  5. Musculoskeletal ultrasonography in children

    International Nuclear Information System (INIS)

    Teo, E.-L.H.; Strouse, P.J.; Chhem, R.K.

    2002-01-01

    With the development of high-resolution ultrasound transducers, the role of ultrasonography (US) in evaluating the musculoskeletal system has increased. It is now possible to obtain detailed images of bones and soft-tissue structures that were previously unattainable. The advantages of US, when compared with other imaging modalities, are many. It is less expensive than magnetic resonance imaging (MRI) and computed tomography (CT). It does not expose the patient to ionizing radiation, so US examinations can be repeated without harm to the patient. Furthermore, US is performed in real-time, making it possible to assess the musculoskeletal system dynamically, in multiple planes and with contralateral comparison. In experienced hands, US is a quick, noninvasive and cost-effective way to assess the musculoskeletal system in children. It is used to evaluate soft-tissue masses, joint swelling, infections, lesions involving the chest and abdominal walls, bones, muscles and clubfoot deformity and to locate any foreign bodies. (author)

  6. Multiple Diagnostic Imaging of a Patient with Solid Pseudopapillary Tumour of the Pancreas: EUS, CT and FDG PET/CT

    International Nuclear Information System (INIS)

    Chong, Ari; Ha, Jungmin; Kwon, Seong Young

    2014-01-01

    Solid pseudopapillary neoplam of the pancreas (SPNP) is a rare tumour, making up approximately 1 % to 3 % of pancreatic tumours. About 90 % of SPNPs occur in young women (mean age 35 years). SPNP rarely causes symptoms and is usually detected incidentally. Differentiating SPNP from other pancreatic tumours is very important, because surgical resection may provide favourable outcomes. Metastases or invasion to other organs has been reported in 15% to 20% of patients with SPNP. Histologically, the uniform, bland-appearing, epithelial cells of SPNP are similar to the cells making up other pancreatic endocrine neoplasms. However, SPNP cannot be regarded as a pure pancreatic endocrine neoplasm because of the absence of chromogranin A expression and low expression of other endocrine markers. SPNP has not been associated with specific serum tumour markers. CT and MRI are used for the diagnosis and staging of SPNP. On contrast-enhanced CT, SPNP shows isoattenuation on precontrast CT, weak enhancement during the arterial phase and gradually increased enhancement during the portal venous phase. SPNP can appear as an encapsulated lesion with cystic degeneration, necrosis, haemorrhage or calcification. MRI can characterise internal signal intensities, including a blood component, which is helpful in making a differential diagnosis. Dong et al. analysed CT and MRI findings from eight patients with SPNP and reported that four lesions showed mixed solid and cystic components, and the others appeared almost completely solid. Stoita et al. reported that EUS-guided fine-needle aspiration was a minimally invasive, safe and reliable diagnostic method for SPNP. They reported that all seven lesions examined were hypoechoic, heterogeneous and well circumscribed. Their findings are very similar to the findings in our patient. In addition, it is clear from the EUS images of our patient that EUS provides better images for evaluating SPNP lesions than US of the pancreas (Figs. 1e and f and 2

  7. EUS-guided recanalization of complete gastrointestinal strictures

    Directory of Open Access Journals (Sweden)

    Miguel Martínez-Guillén

    Full Text Available Background and aim: Complete gastrointestinal strictures are a technically demanding problem. In this setting, an anterograde technique is associated with a high risk of complications and a combined anterograde-retrograde technique requires a prior ostomy. Our aim was to assess the outcome of a first case series for the management of complete gastrointestinal strictures using endoscopic ultrasound (EUS-guided puncture as a novel endoscopic approach. Patients and methods: This retrospective case-series describes four cases that were referred for treatment of complete benign gastrointestinal strictures, three upper and one lower. Recanalization was attempted with EUS-guided puncture using a 22G or 19G needle and contrast filling was visualized by fluoroscopy. Afterwards, a cystotome and/or a dilator balloon were used under endoscopic and fluoroscopic guidance. A fully covered metal stent was placed in two cases, keeping the strictures open in order to prevent another stricture. Feasibility, adverse events, efficacy and the number of dilations required after recanalization were evaluated. Results: Technical and clinical success was achieved in three of the four cases (75%. A first dilation was performed using a dilator balloon in all successful cases and fully covered metal stents were used in two cases. These patients underwent a consecutive number of balloon dilatations (range 1-4 and all three were able to eat a soft diet. No adverse events were related to the EUS-guided approach. In the failed case with a long stricture (> 3 cm, an endoscopic rendezvous technique was attempted which caused a pneumothorax requiring a chest tube placement. Conclusion: EUS-guided recanalization, as a first approach in the treatment of complete digestive stricture, is a feasible and promising procedure that can help to avoid major surgery.

  8. Imaging in rheumatoid arthritis--status and recent advances for magnetic resonance imaging, ultrasonography, computed tomography and conventional radiography

    DEFF Research Database (Denmark)

    Østergaard, Morten; Pedersen, Susanne Juhl; Dohn, U.M.

    2008-01-01

    , and have several documented and potential applications in RA patients. This chapter will review key aspects of the current status and recent important advances in imaging in RA, briefly discussing X-ray and computed tomography, and particularly focusing on MRI and US. Suggestions for use in clinical trials...

  9. The use of endoscopic ultrasonography in the diagnosis of the causes of common bile duct dilation

    International Nuclear Information System (INIS)

    Sajewicz, Z.; Wozniak-Stolarska, B.; Salomon, A.; Poniewierka, E.; Kempinski, R.

    2006-01-01

    Background. Ultrasonography (US) does not come up to the expectations in the diagnosis of the causes of common bile duct (CBD) dilation. Objectives. An assessment of the usefulness of endoscopic ultrasonography (EUS) in the diagnosis of the causes of CBD dilation. Material and Methods. The authors examined 30 persons (16 females and 14 males) with CBD dilated > 7 mm in US. In these patients the authors performed EUS with the usage of Pentax FG-38UX echoendoscope of 5-10 MHz frequency connected with EUB 6000 Hitachi ultrasonograph looking for the cause of CBD dilation. Findings gathered were verified with the usage of endoscopic retrograde cholangiopancreatography (ERCP) or magnetic resonance cholangiopancreatography (MRCP). Results. In 16 patients the authors found stones in CBD. In ERCP or MRCP the frequency of CBD stones was a bit higher. In these examinations CBD stones were found in 18 patients. The authors found out that pancreatic head carcinoma was the cause of CBD dilation in 8 patients; in 2 patients the authors diagnosed ampullary carcinoma and in 1 patient - carcinoma of distal part of CBD. In 1 patient the authors pointed out a benign stricture of CBD with dilation above the stricture. Conclusions. EUS is a useful diagnosing method of the causes of CBD dilation. (authors)

  10. Microscopic findings in EUS-guided fine needle (SharkCore) biopsies with type 1 and type 2 autoimmune pancreatitis

    DEFF Research Database (Denmark)

    Detlefsen, Sönke; Joergensen, Maiken Thyregod; Mortensen, Michael Bau

    2017-01-01

    The International Consensus Diagnostic Criteria (ICDC) for the diagnosis of autoimmune pancreatitis (AIP) include the histological criterion that is based on either pancreatic core needle biopsies (CNBs) or surgical specimens. However, CNBs are difficult to obtain by endoscopic ultrasound (EUS......). EUS fine-needle aspiration (EUS-FNA) cytology is usually not sufficient for the diagnosis of AIP, but may sometimes contain tissue microfragments. Another approach is EUS-guided histological fine-needle biopsy (EUS-FNB), using needles such as the SharkCore or ProCore needle. Published data regarding...... EUS-guided SharkCore FNB for the diagnosis of AIP are lacking. We aimed to describe our histological findings in one type 1 and two type 2 AIP patients who underwent EUS SharkCore FNB. The EUS-FNBs of two patients fulfilled the histological level 2 ICDC for type 1 AIP or type 2 AIP. The EUS-FNB of one...

  11. Electrocautery vs non-electrocautery dilation catheters in endoscopic ultrasonography-guided pancreatic fluid collection drainage

    Science.gov (United States)

    Kitamura, Katsuya; Yamamiya, Akira; Ishii, Yu; Nomoto, Tomohiro; Honma, Tadashi; Yoshida, Hitoshi

    2016-01-01

    AIM: To investigate the safety and utility of an electrocautery dilation catheter for endoscopic ultrasonography (EUS)-guided pancreatic fluid collection drainage. METHODS: A single-center, exploratory, retrospective study was conducted between August 2010 and August 2014. This study was approved by the Medical Ethics Committee of our institution. Informed, written consent was obtained from each patient prior to the procedure. The subjects included 28 consecutive patients who underwent EUS-guided transmural drainage (EUS-TD) for symptomatic pancreatic and peripancreatic fluid collections (PFCs) by fine needle aspiration using a 19-gauge needle. These patients were retrospectively divided into two groups based on the use of an electrocautery dilation catheter as a fistula dilation device; 15 patients were treated with an electrocautery dilation catheter (electrocautery group), and 13 patients were treated with a non-electrocautery dilation catheter (non-electrocautery group). We evaluated the technical and clinical successes and the adverse events associated with EUS-TD for the treatment of PFCs between the two groups. RESULTS: There were no significant differences in age, sex, type, location and diameter of PFCs between the groups. Thirteen patients (87%) in the electrocautery group and 10 patients (77%) in the non-electrocautery group presented with infected PFCs. The technical success rates of EUS-TD for the treatment of PFCs were 100% (15/15) and 100% (13/13) for the electrocautery and the non-electrocautery groups, respectively. The clinical success rates of EUS-TD for the treatment of PFCs were 67% (10/15) and 69% (9/13) for the electrocautery and the non-electrocautery groups, respectively (P = 0.794). The procedure time of EUS-TD for the treatment of PFCs in the electrocautery group was significantly shorter than that of the non-electrocautery group (mean ± SD: 30 ± 12 min vs 52 ± 20 min, P electrocautery and the non-electrocautery groups, respectively (P

  12. Subset Analysis of a Multicenter, Randomized Controlled Trial to Compare Magnifying Chromoendoscopy with Endoscopic Ultrasonography for Stage Diagnosis of Early Stage Colorectal Cancer.

    Science.gov (United States)

    Yamada, Tomonori; Shimura, Takaya; Ebi, Masahide; Hirata, Yoshikazu; Nishiwaki, Hirotaka; Mizushima, Takashi; Asukai, Koki; Togawa, Shozo; Takahashi, Satoru; Joh, Takashi

    2015-01-01

    Our recent prospective study found equivalent accuracy of magnifying chromoendoscopy (MC) and endoscopic ultrasonography (EUS) for diagnosing the invasion depth of colorectal cancer (CRC); however, whether these tools show diagnostic differences in categories such as tumor size and morphology remains unclear. Hence, we conducted detailed subset analysis of the prospective data. In this multicenter, prospective, comparative trial, a total of 70 patients with early, flat CRC were enrolled from February 2011 to December 2012, and the results of 66 lesions were finally analyzed. Patients were randomly allocated to primary MC followed by EUS or to primary EUS followed by MC. Diagnoses of invasion depth by each tool were divided into intramucosal to slight submucosal invasion (invasion depth final pathological diagnosis by an independent pathologist blinded to clinical data. To standardize diagnoses among examiners, this trial was started after achievement of a mean κ value of ≥0.6 which was calculated from the average of κ values between each pair of participating endoscopists. Both MC and EUS showed similar diagnostic outcomes, with no significant differences in prediction of invasion depth in subset analyses according to tumor size, location, and morphology. Lesions that were consistently diagnosed as Tis/T1-SMS or ≥T1-SMD with both tools revealed accuracy of 76-78%. Accuracy was low in borderline lesions with irregular pit pattern in MC and distorted findings of the third layer in EUS (MC, 58.5%; EUS, 50.0%). MC and EUS showed the same limited accuracy for predicting invasion depth in all categories of early CRC. Since the irregular pit pattern in MC, distorted findings to the third layer in EUS and inconsistent diagnosis between both tools were associated with low accuracy, further refinements or even novel methods are still needed for such lesions. University hospital Medical Information Network Clinical Trials Registry UMIN 000005085.

  13. Ultrasonography versus intravenous urography

    International Nuclear Information System (INIS)

    Aslaksen, A.

    1991-01-01

    The present study was performed to compare the clinical value of urography and ultrasonography in a non-selected group of patients referred for urography to a university hospital. The conslusions and clinical implications of the study are as follows: Intravenous urography remains the cornerstone imaging examination in the evaluation of ureteral calculi. Ultrasonography is a valuable adjunct in cases of non- visualization of the kidneys, in distal obstruction and known contrast media allergy. When women with recurrent urinary tract infection are referred for imaging of the urinary tract, ultrasonography should be used. Ultrasonography should replace urography for screening of non-acute hydronephrosis like in female genital cancer and benign prostate hyperplasia. There is good correlation between urography and ultrasonography in assessing the degree of hydronephrosis. However, more researh on the relationship between hydronephrosis and obstruction is necessary. Ultrasonography should be used as the only imaging method of the upper urinary tract in patients with microscopic hematuria. In patients less than 50 years with macroscopic hematuria, ultrasonography should be used as the only imaging of the upper urinary tract, and an examination of the urinary bladder should be included. In patients over 50 years, urography supplied with ultrasonography should be used, but more research is necessary on the subject of imaging method and age. 158 refs

  14. Role of endoscopic ultrasonography in evaluation of metastatic lesions to the pancreas: a tertiary cancer center experience.

    Science.gov (United States)

    Atiq, Muslim; Bhutani, Manoop S; Ross, William A; Raju, Gottumukkala S; Gong, Yun; Tamm, Eric P; Javle, Milind; Wang, Xuemei; Lee, Jeffrey H

    2013-04-01

    Metastatic lesions to the pancreas pose diagnostic challenges with regards to their differentiation from primary pancreatic cancer. Data on the yield of endoscopic ultrasonography (EUS)-guided fine-needle aspiration in detection of these lesions are limited. This is a retrospective review of 23 patients referred to a tertiary referral center for further evaluation of suspected pancreatic metastases. Main outcome measures were diagnostic yield of endoscopic ultrasonography-guided fine-needle aspiration in evaluation of metastatic lesions to the pancreas. Of 644 patients, 23 (3.6%) undergoing EUS of the pancreas were diagnosed to have metastatic disease to the pancreas based on clinical, radiological, and cytological results. Mean (SD) age was 64.3 (11.7) years. Of the 23 patients, 18 (78.3%) were asymptomatic. Mean (SD) size of lesion on EUS was 39.1 (19.9) mm. A diagnosis of malignant lesion was made in 21 of 23 cases, with a diagnostic accuracy of 91.3%. Metastatic lesions to the pancreas present as incidental, solitary mass lesions on staging or surveillance imaging. Endoscopic ultrasonography-guided fine-needle aspiration is an important tool in the characterization and further differentiation of metastatic lesions to the pancreas from primary pancreatic cancer.

  15. Which supplementary imaging modality should be used for breast ultrasonography? Comparison of the diagnostic performance of elastography and computer-aided diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Si Eun; Moon, Ji Eun Ho; Kim, Eun Kyung; Yoon, Jung Hyun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    The aim of this study was to evaluate and compare the diagnostic performance of grayscale ultrasonography (US), US elastography, and US computer-aided diagnosis (US-CAD) in the differential diagnosis of breast masses. A total of 193 breast masses in 175 consecutive women (mean age, 46.4 years) from June to August 2015 were included. US and elastography images were obtained and recorded. A US-CAD system was applied to the grayscale sonograms, which were automatically analyzed and visualized in order to generate a final assessment. The final assessments of breast masses were based on the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) categories, while elasticity scores were assigned using a 5-point scoring system. The diagnostic performance of grayscale US, elastography, and US-CAD was calculated and compared. Of the 193 breast masses, 120 (62.2%) were benign and 73 (37.8%) were malignant. Breast masses had significantly higher rates of malignancy in BI-RADS categories 4c and 5, elastography patterns 4 and 5, and when the US-CAD assessment was possibly malignant (all P<0.001). Elastography had higher specificity (40.8%, P=0.042) than grayscale US. US-CAD showed the highest specificity (67.5%), positive predictive value (PPV) (61.4%), accuracy (74.1%), and area under the curve (AUC) (0.762, all P<0.05) among the three diagnostic tools. US-CAD had higher values for specificity, PPV, accuracy, and AUC than grayscale US or elastography. Computer-based analysis based on the morphologic features of US may be very useful in improving the diagnostic performance of breast US.

  16. Preparation of EuSe nanoparticles from Eu(III) complex containing selenides

    International Nuclear Information System (INIS)

    Adachi, Taka-aki; Tanaka, Atsushi; Hasegawa, Yasuchika; Kawai, Tsuyoshi

    2008-01-01

    The EuSe nanoparticles were prepared by the thermal reduction of Europium nitrate with new organic selenium compound, tetraphenylphosphonium diphenylphosphinediselenide (PPh 4 )(Se 2 P(C 6 H 5 ) 2 ), for the first time. EuSe nanoparticles were identified by the X-ray diffraction (XRD), the transmission electron microscope (TEM) and the energy dispersive X-ray spectroscopy (EDX) measurements. The average size of the EuSe nanoparticles was found to be 19 nm. The energy gap in EuSe nanoparticles of 19 nm was estimated by edge of absorption band, giving the energy gap of 1.86 eV

  17. Lung Ultrasonography in Patients With Idiopathic Pulmonary Fibrosis: Evaluation of a Simplified Protocol With High-Resolution Computed Tomographic Correlation.

    Science.gov (United States)

    Vassalou, Evangelia E; Raissaki, Maria; Magkanas, Eleftherios; Antoniou, Katerina M; Karantanas, Apostolos H

    2018-03-01

    To compare a simplified ultrasonographic (US) protocol in 2 patient positions with the same-positioned comprehensive US assessments and high-resolution computed tomographic (CT) findings in patients with idiopathic pulmonary fibrosis. Twenty-five consecutive patients with idiopathic pulmonary fibrosis were prospectively enrolled and examined in 2 sessions. During session 1, patients were examined with a US protocol including 56 lung intercostal spaces in supine/sitting (supine/sitting comprehensive protocol) and lateral decubitus (decubitus comprehensive protocol) positions. During session 2, patients were evaluated with a 16-intercostal space US protocol in sitting (sitting simplified protocol) and left/right decubitus (decubitus simplified protocol) positions. The 16 intercostal spaces were chosen according to the prevalence of idiopathic pulmonary fibrosis-related changes on high-resolution CT. The sum of B-lines counted in each intercostal space formed the US scores for all 4 US protocols: supine/sitting and decubitus comprehensive US scores and sitting and decubitus simplified US scores. High-resolution CT-related Warrick scores (J Rheumatol 1991; 18:1520-1528) were compared to US scores. The duration of each protocol was recorded. A significant correlation was found between all US scores and Warrick scores and between simplified and corresponding comprehensive scores (P idiopathic pulmonary fibrosis. The 16-intercostal space simplified protocol in the lateral decubitus position correlated better with high-resolution CT findings and was less time-consuming compared to the sitting position. © 2017 by the American Institute of Ultrasound in Medicine.

  18. COMPARISONS AMONG RADIOGRAPHY, ULTRASONOGRAPHY AND COMPUTED TOMOGRAPHY FOR EX VIVO CHARACTERIZATION OF STIFLE OSTEOARTHRITIS IN THE HORSE.

    Science.gov (United States)

    De Lasalle, Julie; Alexander, Kate; Olive, Julien; Laverty, Sheila

    2016-09-01

    A better understanding of imaging characteristics of equine stifle osteoarthritis (OA) may allow earlier detection and improve prognosis. Objectives of this ex vivo, prospective, methods comparison study were to (1) describe the location and severity of naturally acquired OA lesions in the equine stifle using ultrasound (US), radiography (XR), computed tomography (CT), and macroscopic evaluation (ME); (2) compare the diagnostic performance of each imaging modality with ME; and (3) describe subchondral bone mineral density (BMD) in equine stifle joints with OA using CT. Radiographic, CT, and US evaluations were performed on 23 equine cadaver stifles and compared with ME. Significant associations were found between osteophyte global scores for all imaging modalities (CT, P ˂ 0.0001; XR, P = 0.005; US, P = 0.04) vs. ME osteophyte global scores. Osteophytes were detected most frequently in the medial femorotibial (MFT) joint. A specific pattern of osteophytes was observed, with a long ridge of new bone at the insertion of the MFT joint capsule cranially on the medial femoral condyle. A novel caudo-10°proximo-5°lateral-cranio-disto-medial oblique radiographic projection was helpful for detection of intercondylar osteophytes. Multiplanar CT reformatted images were helpful for characterizing all osteophytes. Osteophyte grades at most sites did not differ among modalities. Low sensitivity/specificity for subchondral bone sclerosis and flattening of femoral condyles suggested that these signs may not be reliable radiographic and CT indicators of equine stifle OA. Equine stifle OA was associated with a decrease in BMD and specific sites of focal subchondral bone resorption/cyst formation were found in some specimens. © 2016 American College of Veterinary Radiology.

  19. Clinical utility and prospective comparison of ultrasonography and computed tomography imaging in staging of neck metastases in head and neck squamous cell cancer in an Indian setup

    International Nuclear Information System (INIS)

    Ashraf, M.; Biswas, J.; Jha, J.; Nayak, S.; Singh, V.; Majumdar, S.; Bhowmick, A.; Dam, A.

    2011-01-01

    Preoperative lymph node screening of all neck compartments is favored by clinicians for the management of the neck. The presence of a metastatic node on one side of the neck reduces the 5-year survival rate to 50%, and the presence of a metastatic node on both sides of the neck reduces the 5-year survival rate to 25%. This study compared the evaluation of lymph node metastases by ultrasonography (USG) and computed tomography (CT) in patients with squamous cell cancer of the head and neck region. Five hundred and eighty-four patients with squamous cell cancer of the head and neck were prospectively evaluated for the presence of cervical lymph node metastases. All patients underwent clinical examination (palpation), USG and CT imaging. Neck dissection was performed in all the patients, and the results of the preoperative evaluation were correlated with the surgical and histopathological findings. Metastases in neck nodes were identified in 148 patients by histopathological examination. Doppler USG correctly identified 136 node-positive patients (n=148; sensitivity 91.8%, specificity 97%). CT imaging correctly identified 122 patients with metastatic lymph nodes (n=148; sensitivity 83%, specificity 93%). Positive predictive values of USG and CT imaging were 95.6% and 91.3%, respectively, whereas the negative predictive values of these two imaging studies were 95.4% and 89.6%, respectively. The accuracy and sensitivity of USG in detection of cervical lymph node metastases make it a potentially promising and cheap preoperative tool for staging neck node metastases and optimizing the treatment plan for surgeons, especially in countries such as India. (author)

  20. Comparison of gray-scale contrast-enhanced ultrasonography with contrast-enhanced computed tomography in different grading of blunt hepatic and splenic trauma: an animal experiment.

    Science.gov (United States)

    Tang, Jie; Li, Wenxiu; Lv, Faqin; Zhang, Huiqin; Zhang, Lihai; Wang, Yuexiang; Li, Junlai; Yang, Li

    2009-04-01

    To compare the diagnostic value of contrast-enhanced ultrasonography (CEUS) with contrast-enhanced computed tomography (CECT) for the detection of different grading of solid organ injuries in blunt abdominal trauma in animals. A self-made miniature tools were used as models to simulate a blunt hepatic or splenic trauma in 16 and 14 anesthetized dogs, respectively. Baseline ultrasound, CEUS and CECT were used to detect traumatic injuries of livers and spleens. The degree of injuries was determined by CEUS according to the American Association for the Surgery of Trauma (AAST) scale and the results compared with injury scale based on CECT evaluation. CEUS showed 22 hepatic injury sites in 16 animals and 17 splenic injury sites in other 14 animals. According to AAST scale, 2 grade I, 4 grade II, 3 grade III, 5 grade IV and 2 grade V hepatic lesions were present in 16 animals; 2 grade I, 4 grade II, 6 grade III and 2 grade IV splenic lesions in 14 animals. On CECT scan, 21 hepatic and 17 splenic injuries were demonstrated. According to Becker CT scaling for hepatic injury, 1 grade I, 2 grade II, 4 grade III, 5 grade IV and 2 grade V hepatic injuries were present. On the basis of Buntain spleen scaling, 2 grade I, 5 grade II, 5 grade III, 2 grade IV splenic injuries were showed. After Spearman rank correlation analysis, the agreement of CEUS with CECT on the degree of hepatic and splenic injury is 93.3% and 92.9%, respectively. CT is currently considered as the reference method for grading blunt abdominal trauma, according to experiment results, CEUS grading showed high levels of concordance with CECT. CEUS can accurately determine the degree of injury and will play an important role in clinical application.

  1. Endosonography for suspected obstructive jaundice with no definite pathology on ultrasonography.

    Science.gov (United States)

    Chen, Chien-Hua; Yang, Chi-Chieh; Yeh, Yung-Hsiang; Yang, Tsang; Chung, Tieh-Chi

    2015-09-01

    Ultrasonography (US) cannot demonstrate all the etiologies of biliary tract dilatation in patients with jaundice. Thus, we evaluated the etiologic yield of endosonography (EUS) for suspected obstructive jaundice when no definite pathology was found on US. Additionally, we sought to identify the predictors of the most common etiologies. We performed a retrospective review of 123 consecutive patients who had undergone EUS for suspected obstructive jaundice when no definite pathology was identified on US. The most common diagnoses included no pathological obstruction (n = 43), pancreatobiliary malignancy (n = 41), and choledocholithiasis (n = 28). Pancreatobiliary malignancy was associated with common bile duct (CBD) dilatation, and fever and elevated alanine aminotransferase were predictors of choledocholithiasis (p jaundice, 100% (40/40) for no pathological finding, 100% (23/23) for ampullary cancer, 100% (13/13) for pancreatic cancer, 75% (3/4) for CBD cancer, and 92.9% (26/28) for choledocholithiasis, respectively. Besides the two patients with focal chronic pancreatitis misdiagnosed as with pancreatic cancer, EUS missed the lesions in one CBD cancer patient and two patients with choledocholithiasis. The overall accuracy of EUS in ascertaining pancreatobiliary malignancy and choledocholithiasis was comparable (97.6%, 40/41 vs. 92.9%, 26/28; p > 0.05). Marked CBD dilatation (≥12 mm) should remind us of the high risk of malignancy, and the presence of CBD dilatation and fever is suggestive of choledocholithiasis. Negative EUS findings cannot assure any pathological obstruction in patients with clinically suspected obstructive jaundice. Copyright © 2013. Published by Elsevier B.V.

  2. Prospective evaluation of EUS-guided fine needle biopsy in pancreatic mass lesions

    DEFF Research Database (Denmark)

    Larsen, M H; Fristrup, C W; Detlefsen, S

    2018-01-01

    Background and study aim : Due to the scarcity of specific data on endoscopic ultrasound (EUS)-guided fine-needle biopsies (SharkCore) FNB in the evaluation of pancreatic lesions, we performed a prospective study of the diagnostic performance of EUS SharkCore FNB in patients with pancreatic lesions...

  3. Diagnostic yield of EUS-guided FNA and cytology in suspected tubercular intra-abdominal lymphadenopathy

    DEFF Research Database (Denmark)

    Puri, Rajesh; Mangla, Rakhee; Eloubeidi, Mohamad

    2012-01-01

    Intra-abdominal lymphadenopathy is a common diagnostic challenge faced by clinicians. In the absence of palpable peripheral nodes, tissue is usually obtained from the abdominal nodes by image-guided biopsy or surgery. We speculate that EUS-guided FNA (EUS-FNA) avoids the morbidity of a laparotomy...

  4. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  5. Endoscopic ultrasonography-guided pancreatic duct access: techniques and literature review of pancreatography, transmural drainage and rendezvous techniques.

    Science.gov (United States)

    Itoi, Takao; Kasuya, Kazuhiko; Sofuni, Atsushi; Itokawa, Fumihide; Kurihara, Toshio; Yasuda, Ichiro; Nakai, Yousuke; Isayama, Hiroyuki; Moriyasu, Fuminori

    2013-05-01

    Endoscopic ultrasonography-guided (EUS)-guided pancreatic interventions have gained increasing attention. Here we review EUS-guided pancreatic duct (PD) access techniques and outcomes. EUS-guided PD intervention is divided into two types, antegrade and rendezvous techniques, following EUS-guided pancreatography. In the antegrade technique, pancreaticoenterostomy is carried out by stent placement between the PD and the stomach, duodenum, or jejunum. Transenteric antegrade PD stenting is conducted by stent placement, advancing anteriorly into the PD through the pancreatic tract. The rendezvous technique is carried out by using a guidewire through the papilla or anastomotic site for retrograde stent insertion. In terms of EUS-guided PD stenting, 11 case reports totaling 75 patients (35 normal anatomy, 40 altered anatomy) have been published. The technical success rate was greater than 70%. Early adverse events, including severe hematoma and severe pancreatitis,occurred in seven (63.6%) of 11 reports. Regarding the rendezvous technique, 12 case reports totaling 52 patients (22 normal anatomy, 30 altered anatomy) have been published. The technical success rate ranged from 25% to 100%. It was 48% in one report that involved more than 20 cases. Once stents were placed, all patients became free of symptoms. Early mild adverse events occurred in four (36.4%) of 11 reports. In conclusion, although it can be risky because of possible serious or even fatal adverse events, including pancreatic juice leakage, perforation and severe acute pancreatitis, EUS-PD access seems to be promising for treating symptomatic pancreatic diseases caused by PD stricture and pancreaticoenterostomy stricture. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  6. Real time elastography endoscopic ultrasound (RTE-EUS), a comprehensive review

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, C.F., E-mail: christoph.dietrich@ckbm.de [Med. Klinik 2, Caritas-Krankenhaus Bad Mergentheim (Germany); Department of Gastroenterology, Research Center of Gastroenterology and Hepatology, University of Medicine and Pharmacy of Craiova (Romania); Klinik für Innere Medizin, Krankenhaus Märkisch Oderland (Germany); Săftoiu, A.; Jenssen, C. [Med. Klinik 2, Caritas-Krankenhaus Bad Mergentheim (Germany); Department of Gastroenterology, Research Center of Gastroenterology and Hepatology, University of Medicine and Pharmacy of Craiova (Romania); Klinik für Innere Medizin, Krankenhaus Märkisch Oderland (Germany)

    2014-03-15

    Real-time elastography (RTE) performed during endoscopic ultrasound (EUS) is a relatively new technique which allows the evaluation of tissue stiffness, with the intent of better characterising lesions during EUS examinations. The aim of this comprehensive review was to describe the technique of RTE-EUS, as well as the clinical applications, including the study of pancreatic lesions, but also hepatobiliary, gastrointestinal (GI) tract pathology (including anal canal), lymph nodes, adrenal glands, lung and mediastinum, as well as urogenital applications. One of the advantages of the RTE-EUS technique is especially the possibility to be used in various locations accessible from the GI tract. Future developments are also briefly discussed, as elastography is a tissue characterising technique that will certainly not replace biopsy, but will rather be an adjunct during EUS examinations, due to its ease of use and low cost.

  7. Real time elastography endoscopic ultrasound (RTE-EUS), a comprehensive review

    International Nuclear Information System (INIS)

    Dietrich, C.F.; Săftoiu, A.; Jenssen, C.

    2014-01-01

    Real-time elastography (RTE) performed during endoscopic ultrasound (EUS) is a relatively new technique which allows the evaluation of tissue stiffness, with the intent of better characterising lesions during EUS examinations. The aim of this comprehensive review was to describe the technique of RTE-EUS, as well as the clinical applications, including the study of pancreatic lesions, but also hepatobiliary, gastrointestinal (GI) tract pathology (including anal canal), lymph nodes, adrenal glands, lung and mediastinum, as well as urogenital applications. One of the advantages of the RTE-EUS technique is especially the possibility to be used in various locations accessible from the GI tract. Future developments are also briefly discussed, as elastography is a tissue characterising technique that will certainly not replace biopsy, but will rather be an adjunct during EUS examinations, due to its ease of use and low cost

  8. Ultrasonography in trauma

    DEFF Research Database (Denmark)

    Weile, Jesper; Nielsen, Klaus; Primdahl, Stine C

    2017-01-01

    BACKGROUND: The Focused Assessment with Sonography in Trauma (FAST) protocol is considered beneficial in emergent evaluation of trauma patients with blunt or penetrating injury and has become integrated into the Advanced Trauma Life Support (ATLS) protocol. No guidelines exist as to the use...... of ultrasonography in trauma in Denmark. We aimed to determine the current use of ultrasonography for assessing trauma patients in Denmark. METHODS: We conducted a nation-wide cross-sectional investigation of ultrasonography usage in trauma care. The first phase consisted of an Internet-based investigation....... Twenty-one (95.5%) of the guidelines included and recommended FAST as part of trauma assessment. The recommended person to perform the examination was the radiologist in n = 11 (50.0%), the surgeon in n = 6 (27.3%), the anesthesiologist in n = 1 (4.5%), and unspecified in n = 3 (13.6%) facilities. FAST...

  9. Ultrasonography of polycystic kidney

    International Nuclear Information System (INIS)

    Oh, Seung Chul; Cho, Seung Gi; Lee, Kwan Seh; Kim, Kun Sang

    1980-01-01

    Polycystic disease is defined as a heritable disorder with diffuse involvement of both kidneys. The term 'Polycystic disease' comprises at least two separate, genetically different disease-one with an onset typically in childhood (infantile polycystic disease) and the other with an onset typically in adulthood (adult polycystic disease). Adult polycystic kidney disease is the most common form of cystic kidney disease in humans. Ultrasonography is a very useful noninvasive diagnostic modality in the patient with clinically suspected renal diseases as well as screening test. 14 cases of ultrasonography in patient with polycystic kidney were reviewed. All cases show unilateral or bilateral enlarged kidneys. 7 cases reveal kidneys and liver replaced by multiple cysts of varing size. Screening ultrasonography for a familial tree is reported

  10. Normal anatomy of the anal wall and perianal spaces: An EUS, MRI and cadaveric correlative study

    International Nuclear Information System (INIS)

    Chung, Soo Young; Ryu, Sie Tae; Park, Ki Soon; Lee, Yul; Bae, Sang Hoon; Kang, Heung Sik

    1994-01-01

    To understand the normal endosonographic anatomy of the perianal spaces, and to evaluate the diagnostic efficacy and limitation of endorectal sonography(EUS), correlative study with MRI, cadaveric sectional image and cadaveric MRI were performed. EUS images of the normal 6 perianal spaces (pelvirectal, ischiorectal, intersphincteric, subcutaneous, central, submucous space) which were bounded by internal and external anal sphincters, rectal wall and levator ani muscle were correlated with MRI in 10 normal persons, cadaveric sectional images and cadaveric MRI in 2 cadavers. Pelvirectal space located superior to levator ani muscle could be demonstrable only on anterior wall scan but could not be visualized on lateral or posterior wall scan on EUS. Five perianal spaces located inferior to levator ani muscle were well seen on anterior, lateral, and posterior wall EUS. MRI was superior to EUS in the evaluation of pelvirectal and ischiorectal spaces but equal or inferior to EUS in the evaluation of intersphincteric, subcutaneous, central and submucous spaces. EUS was valuable in the evaluation of perianal spaces inferior to levator ani muscle but was limited in the evaluation of perianal spaces superior to levator ani muscle

  11. Accuracy and Quality Assessment of EUS-FNA: A Single-Center Large Cohort of Biopsies

    Directory of Open Access Journals (Sweden)

    Benjamin Ephraim Bluen

    2012-01-01

    Full Text Available Introduction. Thorough quality control (QC study with systemic monitoring and evaluation is crucial to optimizing the effectiveness of EUS-FNA. Methods. Retrospective analysis was composed of investigating consecutive patient files that underwent EUS-FNA. QC specifically focused on diagnostic accuracy, impacts on preexisting diagnoses, and case management. Results. 268 patient files were evaluated. EUS-FNA cytology helped establish accurate diagnoses in 92.54% (248/268 of patients. Sensitivity, specificity, PPV, NPV, and accuracy were 83%, 100%, 100%, 91.6%, and 94%, respectively. The most common biopsy site was the pancreas (68%. The most accurate location for EUS-FNA was the esophagus, 13/13 (100%, followed by the pancreas (89.6%. EUS-FNA was least informative for abdominal lymph nodes (70.5%. After FNA and followup, eight false negatives for tumors were found (3%, while 7.5% of samples still lacked a definitive diagnosis. Discussion. QC suggests that the diagnostic accuracy of EUS-FNA might be improved further by (1 taking more FNA passes from suspected lesions, (2 optimizing needle selection (3 having an experienced echo-endoscopist available during the learning curve, and (4 having a cytologist present during the procedure. QC also identified remediable reporting errors. In conclusion, QC study is valuable in identifying weaknesses and thereby augmenting the effectiveness of EUS-FNA.

  12. Ultrasonography of jaundice

    International Nuclear Information System (INIS)

    Cho, Byung Jae; Bae, Sang Hoon; Lee, Seung Ro; Kim, Chu Wan

    1980-01-01

    The importance of ultrasonography in the evaluation of jaundice is stressed with an analysis of 47 cases of jaundice. 31 cases proved to be obstructive and 16 non-obstructive jaundice. Obstructive jaundice could be differentiated from non-obstructive jaundice in all but 2 cases, (96%). The site of obstruction in 31 cases of obstructive jaundice could be predicted correctly in 23 cases of 31, (90%), and cause of obstruction with an accuracy of 35% as well. One can certainly recommend ultrasonography as an initial procedure of choice in jaundice patients

  13. Ultrasonography in abdominal emergencies

    International Nuclear Information System (INIS)

    Risi, D.; Alessi, G.; Meli, C.; Marzano, M.; Fiori, E.; Caterino, S.

    1989-01-01

    From February 1986 to March 1988 113 abdominal US exams were performed in emergency situation to evaluate the accuracy of this methodology: 13 were blunt traumas, 18 post-operative complications. A real-time scanner with a linear probe of 5 MHz was employed. The results were confirmed by surgical and/or clinical and instrumental evaluation. In 81% of the examinations, ultrasonography allowed a diagnosis to be made. Gallbladder and biliary pathologies were the most common findings. The results (sensibility 96%, specificity 88%, accuracy 95%) confirm the affidability of ultrasonography in abdominal emergencies, as shown in literature

  14. Ultrasonography X gamma radiography

    International Nuclear Information System (INIS)

    Mello Campos, A.M. de

    1989-01-01

    The accumulated experience in the last ten years of substitution to essays by gamma radiography to essay by ultrasonography, starting of the systematic comparison and tabulation of the results obtained by both essays applied in welding joints, in field, in steel pipelines of the SABESP. (V.R.B.)

  15. Surgeon-performed ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias

    2017-01-01

    Surgeons are increasingly using ultrasonography (US) in their clinical management of patients. However, US is a very user-dependent imaging modality and proper skills of the US operator are needed to ensure quality in patient care. This thesis explores the validity evidence for assessment...

  16. Ultrasonography of the Kidney

    DEFF Research Database (Denmark)

    Lindskov Hansen, Kristoffer; Nielsen, Michael Bachmann; Ewertsen, Caroline

    2016-01-01

    Ultrasonography of the kidneys is essential in the diagnosis and management of kidney-related diseases. The kidneys are easily examined, and most pathological changes in the kidneys are distinguishable with ultrasound. In this pictorial review, the most common findings in renal ultrasound...

  17. Detection of hepatic tumor by means of single photon emission computed tomography, gray scale ultrasonography, and x-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yumoto, Yasuhiro; Jinno, Kenji; Tokuyama, Katsuyuki [Shikoku National Cancer Center Hospital, Matsuyama (Japan)

    1984-07-01

    We have studied the detection of hepatic tumor by single photon emmision computed tomography (SPECT) using rotatory chair and gamma camera. SPECT were taken by multiple section slice not in transaxial but also in frontal and sagital view. The detectability of SPECT turned out to be superior to the conventional liver scintiphoto. By SPECT, minute hepatocellular carcinoma (HCC) of 1.9 cm in diameter was detectable. Simultaneous interpretation of SPECT, US and XCT was more helpful than each independent interpertation. Subject comprised 108 patients with focal hepatic lesions including 48 cases of HCC and 44 cases of metastatic liver tumor. SPECT and celiac angiography on a 63-year-old female with liver cirrhosis revealed hepatic mass lesion in subphrenic region in right hepatic lobe, but XCT or US could not detect any lesion of hepatic tumor. Operated specimen showed confluent-massive type of HCC according to Nakashima's classification with 7 x 7 x 6.5 cm in size, representing replacing proliferation by histological examination. Both sensitivity and false positive rate of detectability of HCC were superior in decreasing order as combined three modalities, US XCT and SPECT. The diagnosis by combined three modalities shows 99% of sensitivity rate with 1% of false negative rate and 0% of false positive rate and 99.5% of accuracy. Differenciation of HCC from metastatic liver cancer or another benign tumor was possible with sensitivity rate of 94.8% and specificity rate of 90.0% by three combined modalities.

  18. Evaluation of postoperative anal functions using endoanal ultrasonography and anorectal manometry in children with congenital anorectal malformations.

    Science.gov (United States)

    Wang, Zhichao; Hu, Lijun; Jin, Xianqing; Li, Xiaoqing; Xu, Lixia

    2016-03-01

    The aim of this study was to assess the postoperative anorectal anatomy and function in children with congenital anorectal malformations (ARM) using endoanal ultrasonography (EUS) and anorectal manometry. This study included 47 children who had undergone posterior sagittal anorectoplasty (PSARP) or transperineal anorectoplasty for the repair of an ARM. Children were grouped according to symptoms of defecation disorder, including normal defecation, fecal soiling, fecal incontinence, and constipation. Ten children with no history of anal or rectal diseases served as healthy controls. A well-established scoring system was used for the evaluation of anal function and defecation disorder. EUS showed significant differences in the thickness of the interior sphincter between the ARM patients and the healthy controls (Pinterior sphincters between the PSARP group and transperineal anorectoplasty group (P>0.05). Anorectal manometry showed that the balloon volumes were significantly different between the surgical group and the control group (Pchildren with ARM. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Feasibility study of EUS-NOTES as a novel approach for peroral cholecysto-gastrostomy

    DEFF Research Database (Denmark)

    Saftoiu, Adrian; Vilmann, P; Bhutani, M S

    2013-01-01

    EUS-guided cholecysto-gastrostomy might be a useful minimally invasive procedure used for salvage drainage in advanced pancreaticobiliary cancers, but also for drainage of the gallbladder in acute cholecystitis in patients deemed unfit for laparoscopic surgery.......EUS-guided cholecysto-gastrostomy might be a useful minimally invasive procedure used for salvage drainage in advanced pancreaticobiliary cancers, but also for drainage of the gallbladder in acute cholecystitis in patients deemed unfit for laparoscopic surgery....

  20. Observation of unusual critical region behavior in the magnetic susceptibility of EuSe

    Science.gov (United States)

    Bykovetz, N.; Klein, J.; Lin, C. L.

    2018-05-01

    The Europium Chalcogenides (EuCh: EuO, EuS, EuSe, and EuTe) have been regarded as model examples of simple, cubic, Heisenberg exchange coupled magnetic systems, with a ferromagnetic nearest-neighbor exchange constant J1 and an antiferromagnetic next-nearest-neighbor constant J2. Unlike the other EuCh, EuSe exhibits a range of complex magnetic behaviors, the latter being attributed to EuSe being near the point where J2=-J1, where its magnetism appears to consist of nearly de-coupled 2D ferromagnetic sheets. Analysis of precision SQUID measurements of the magnetic susceptibility χ in EuSe showed that in the region from ˜Tc to ˜2Tc, a fit of the data to the critical equation χ = χ2Tc(T/Tc-1)-γ gives γ=2.0, an exponent not predicted by any current theory. Additionally, this fit predicts that Tc should be ˜0K. We tentatively interpret this by saying that in the paramagnetic region the system "thinks" EuSe should not order above T=0. Tc=0K is predicted by the Mermin-Wagner theorem (MW) for Heisenberg-coupled 2D magnetic systems, and we can show that when J2=-J1, MW can also be applied to the J1, J2 exchange model of the EuCh to give a rigorous Tc=0 prediction. Under 10 kbar applied pressure EuSe exhibits a different γ and fitted Tc. An additional, and rather strange, critical-region effect was discovered. The EuSe sample was found to exhibit a relaxation effect in a small range of temperatures, just above and just below the actual Tc of 4.7K, with time constants of up to 5 minutes. We cannot yet fully explain this observed macroscopic effect.

  1. Transesophageal Ultrasonography for Lung Cancer Staging

    DEFF Research Database (Denmark)

    Konge, Lars; Annema, Jouke; Vilmann, Peter

    2013-01-01

    Accurate mediastinal nodal staging is essential for patients with resectable non-small-cell lung cancer and is achieved by combined endobronchial ultrasound and transesophageal endoscopic ultrasound (EUS). Training requirements for EUS-guided fine-needle aspiration (FNA) for lung cancer staging...

  2. Electron-spin polarization in tunnel junctions with ferromagnetic EuS barriers

    International Nuclear Information System (INIS)

    Hao, X.; Moodera, J.S.; Meservey, R.

    1989-01-01

    The authors report here spin-polarized tunneling experiments using non-ferromagnetic electrodes and ferromagnetic EuS barriers. Because of the conduction band in EuS splits into spin-up and spin-down subbands when the temperature is below 16.7 K, the Curie temperature of EuS, the tunnel barrier for electrons with different spin directions is different, therefore giving rise to tunnel current polarization. The spin-filter effect, as it may be called, was observed earlier, directly or indirectly, by several groups: Esaki et al. made a tunneling study on junctions having EuS and EuSe barriers; Thompson et al. studied Schottky barrier tunneling between In and doped EuS; Muller et al. and Kisker et al. performed electron field emission experiments on EuS-coated tungsten tips. The field emission experiments gave a maximum polarization of (89 + 7)% for the emitted electrons. Although the previous tunneling studies did not directly show electron polarization, their results were explained by the same spin- filter effect. This work uses the spin-polarized tunneling technique to show directly that tunnel current is indeed polarized and polarization can be as high as 85%

  3. Ultrasonography in Obstertrics

    International Nuclear Information System (INIS)

    Lee, Hyon U.

    1982-01-01

    The usefulness of pulse-echo ultrasonography of the practices of obstetrics has been great. It is more reliable than many biochemical and biophysical technics that have been developed in recent years to try to improve pregnancy outcome. When carefully performed and accurately interpreted, it can supply most vital information about the status of the fetus without any known risks to both mother and the fetus itself. The main obstertricalindications of ultrasonography coule be summarized as follows. 1. Diagnosis of early pregnancy. 2. Fetal growth and its maturity. 3. Complications of pregnancy and abnormal pregnancy. a) Vaginal bleeding in early intrauterinepregnancy. b) Multiple pregnancy. c) Ectopic pregnancy d) Hydatidiform mole e) Pelvic mass complicated with pregnancy f) Fetal anomaly 4. Fetal presenation and attitude 5. Placentography

  4. Comparison of EUS-guided rendezvous and precut papillotomy techniques for biliary access (with videos).

    Science.gov (United States)

    Dhir, Vinay; Bhandari, Suryaprakash; Bapat, Mukta; Maydeo, Amit

    2012-02-01

    Precut papillotomy after failed bile duct cannulation is associated with an increased risk of pancreatitis. EUS-guided rendezvous drainage is a novel alternative technique, but there are no data comparing this approach with precut papillotomy. To evaluate the safety and efficacy of EUS-guided rendezvous drainage of the bile duct and compare its outcome with that of precut papillotomy. Retrospective study. Tertiary care referral center. Consecutive patients with distal bile duct obstruction, in whom selective cannulation of the bile duct at ERCP failed after 5 attempts with a guidewire and sphincterotome, underwent an EUS-guided rendezvous procedure. The outcomes were compared with those in a historical cohort of patients who underwent precut papillotomy. Patients in whom selective cannulation failed underwent EUS-guided rendezvous drainage by use of the short wire technique or precut papillotomy by use of the Erlangen papillotome. At EUS, after the extrahepatic bile duct was punctured with a 19-gauge needle, a hydrophilic angled-tip guidewire 260 cm long was passed in an antegrade manner across the papilla into the duodenum. The echoendoscope was then exchanged for a duodenoscope, which was introduced alongside the EUS-placed guidewire. The transpapillary guidewire was retrieved through its biopsy channel, and accessories were passed over the wire to perform the requisite endotherapy. Comparison of the rates of technical success and complications between patients treated by the EUS-guided rendezvous and those treated by precut papillotomy techniques. Treatment success was defined as completion of the requisite endotherapy in one treatment session. Treatment success was significantly higher for the EUS-guided rendezvous (57/58 patients) than for those undergoing precut papillotomy technique (130/144 patients) (98.3% vs 90.3%; P = .03). There was no significant difference in the rate of procedural complications between the EUS and precut papillotomy techniques (3

  5. Single-operator EUS-guided cholangiopancreatography for difficult pancreaticobiliary access (with video).

    Science.gov (United States)

    Brauer, Brian C; Chen, Yang K; Fukami, Norio; Shah, Raj J

    2009-09-01

    When conventional ERCP methods fail because of periampullary or ductal obstruction, EUS-guided cholangiopancreatography (EUS-CP) may aid in pancreaticobiliary access. To report our experience when using single-operator EUS-CP. An academic tertiary-referral center. Consecutive patients undergoing EUS-CP were prospectively identified. These patients had undergone failed attempt(s) at therapeutic ERCP. A data sheet was used to record indications, reasons for failed ERCP, EUS-CP visualization of the duct of interest, transpapillary or transenteric intervention, clinical follow-up, and complications. Technical success was decompression of the duct of interest. Clinical success was resolution of jaundice or a > or = 50% reduction in pain or narcotics, as applicable. Between February 2003 and June 2007, EUS-CP was attempted in 20 patients (11 men, 9 women; mean [SD] age 58 +/- 14.9 years). Indications included jaundice (n = 8), biliary stones (n = 3), chronic pancreatitis (n = 6), acute pancreatitis (n = 2), and papillary stenosis (n = 1). Reasons for failed ERCP included periampullary mass (n = 8), intradiverticular papillae (n = 4), and pancreatic duct (PD) stricture (n = 7) or stone (n = 1). Technical success was achieved in 18 of 20 patients (90%). Biliary decompression was obtained in 11 of 12 patients (92%) (7 transpapillary and 4 transenteric-transcholedochal). Pancreatic decompression was obtained in 7 of 8 patients (88%) (3 transpapillary, 4 transgastric). On follow-up, clinical improvement was noted in 15 of 20 patients (70%). For treatment of pain associated with chronic pancreatitis, pain scores decreased by a mean of 1.75 (P = .18). Complications (in 2 of 20 [10%]) included perforation (n = 1) and respiratory failure (n = 1). A single-center nonrandomized observational study with a small patient population. At our academic referral center, single-operator EUS-CP provided decompression of obstructed ducts and may be performed after a failed attempt at

  6. Acute diverticulitis of the terminal ileum: ultrasonography and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jewon; Hong, Seong Sook; Hwang, Ji Young; Kim, Hyun Joo; Chang, Yun Woo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    2015-01-15

    We describe a rare case of terminal ileal diverticulitis in a 68-year-old female with a day of history Epub ahead of print of right lower quadrant pain and tenderness, mimicking acute appendicitis. Ultrasonography revealed small sac-like out-pouching lesions with increased echogenicity of surrounding fat in thickened terminal ileum, suggesting inflamed diverticula. We diagnosed terminal ileal diverticulitis primarily by ultrasonography. The diagnosis was confirmed by subsequent computed tomography.

  7. Ultrasonography of Neonatal Cholestasis

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, Jung Eun [Seoul National University Hospital, Seoul (Korea, Republic of)

    2012-06-15

    Ultrasonography (US) is as an important tool for differentiation of obstructive and non-obstructive causes of jaundice in infants and children. Beyond two weeks of age, extrahepatic biliary atresia and neonatal hepatitis are the two most common causes of persistent neonatal jaundice: differentiation of extrahepatic biliary atresia, which requires early surgical intervention, is very important. Meticulous analysis should focus on size and configuration of the gallbladder and anatomical changes of the portahepatis. In order to narrow the differential diagnosis, combined approaches using hepatic scintigraphy, MR cholangiography, and, at times, percutaneous liver biopsy are necessary. US is useful for demonstrating choledochal cyst, bile plug syndrome, and spontaneous perforation of the extrahepatic bile duct

  8. Ultrasonography of ovarian hyperandrogenemia

    Science.gov (United States)

    Kuzmina, Svetlana A.; Zharkin, Nikolay A.

    2001-05-01

    The method of ultrasonography is high informative and widely used in diagnostics of ovarian hyperandrogenaemia. The majority of authors consider that a hyperplasia of a stroma is the main pathognomonic marker of polycystic ovaries (PCO). Still recently swell of a stroma was valued visually, that had subjective nature. We offer for the first time a way of diagnostics of stromal hyperplasia grounded on measurement of a volume of a stroma and ovary with ultrasound method, calculation of the ratio of a volume of the ovary to a volume of a stroma for every patient.

  9. Preoperative noninvasive EUS evaluation in patients with esophageal cancer considered for esophagectomy.

    Science.gov (United States)

    Gheorghe, Cristian; Stanescu, Codrut; Gheorghe, Liana; Bancila, Ion; Herlea, Vlad; Becheanu, Gabriel; Voinea, Daniela; Iacob, Razvan; Lupescu, Ioana; Anghel, Rodica; Croitoru, Adina; Popescu, Irinel

    2006-06-01

    Worldwide, esophageal cancer ranks fifth in the mortality rate regarding tumor locations. EUS is an essential tool in the evaluation of these patients allowing accurate staging and permitting stratified treatment options. AIM. We have studied prospectively the impact of EUS in the evaluation and decision for therapy of patients with esophageal cancer diagnosed in our center. From March 2001 through March 2006, 220 patients were hospitalized at the Center of Gastroenterology and Hepatology, Fundeni Clinical Institute, with the diagnosis of esophageal cancer. Out of the 220 patients, 41 patients, with no major comorbidities contraindicating esophagectomy already having been screened by abdominal and thoracic CT to disclose distant metastases, had EUS with the definite purpose of staging esophageal carcinoma and selecting adequate therapy. Assuming that without preoperative staging by EUS, all 41 patients in the study group would have been offered surgical treatment, we evaluated the number of patients and the modality in which EUS resulted in changes to the therapeutic plan. Depth of invasion was recorded for the 41 patients as follows: T1 in 2 patients (4.9%), T2 in 6 patients (14.6%), T3 in 24 patients (58.5%), and T4 in 10 patients (22%). Regional lymph node (N) status as determined by EUS criteria was as follows: N0 in 7 patients (17%) and N1 in 34 patients (83%). Assessment of distant metastases (M) was recorded showing 4 patients with celiac axis lymph nodes metastases (M1). Preoperative EUS staging changed the decision for surgery in 18 of 41 patients (44%) (p<0.0001) and allowed primary esophagectomy in only 6 patients (15%) (p<0.0001). Compared to histopathology, the overall accuracy of EUS staging for pT1 and pT2 was 80% for staging pT3 and pT4 77% and for lymph node evaluation was approximately 75%. Esophageal EUS offers useful information to clinicians caring for patients with esophageal cancer, impacts clinical decision making, and should be used in

  10. Subset Analysis of a Multicenter, Randomized Controlled Trial to Compare Magnifying Chromoendoscopy with Endoscopic Ultrasonography for Stage Diagnosis of Early Stage Colorectal Cancer.

    Directory of Open Access Journals (Sweden)

    Tomonori Yamada

    Full Text Available Our recent prospective study found equivalent accuracy of magnifying chromoendoscopy (MC and endoscopic ultrasonography (EUS for diagnosing the invasion depth of colorectal cancer (CRC; however, whether these tools show diagnostic differences in categories such as tumor size and morphology remains unclear. Hence, we conducted detailed subset analysis of the prospective data.In this multicenter, prospective, comparative trial, a total of 70 patients with early, flat CRC were enrolled from February 2011 to December 2012, and the results of 66 lesions were finally analyzed. Patients were randomly allocated to primary MC followed by EUS or to primary EUS followed by MC. Diagnoses of invasion depth by each tool were divided into intramucosal to slight submucosal invasion (invasion depth <1000 μm and deep submucosal invasion (invasion depth ≥1000 μm, and then compared with the final pathological diagnosis by an independent pathologist blinded to clinical data. To standardize diagnoses among examiners, this trial was started after achievement of a mean κ value of ≥0.6 which was calculated from the average of κ values between each pair of participating endoscopists.Both MC and EUS showed similar diagnostic outcomes, with no significant differences in prediction of invasion depth in subset analyses according to tumor size, location, and morphology. Lesions that were consistently diagnosed as Tis/T1-SMS or ≥T1-SMD with both tools revealed accuracy of 76-78%. Accuracy was low in borderline lesions with irregular pit pattern in MC and distorted findings of the third layer in EUS (MC, 58.5%; EUS, 50.0%.MC and EUS showed the same limited accuracy for predicting invasion depth in all categories of early CRC. Since the irregular pit pattern in MC, distorted findings to the third layer in EUS and inconsistent diagnosis between both tools were associated with low accuracy, further refinements or even novel methods are still needed for such lesions

  11. Novel ex vivo model for hands-on teaching of and training in EUS-guided biliary drainage: creation of "Mumbai EUS" stereolithography/3D printing bile duct prototype (with videos)

    NARCIS (Netherlands)

    Dhir, Vinay; Itoi, Takao; Fockens, Paul; Perez-Miranda, Manuel; Khashab, Mouen A.; Seo, Dong Wan; Yang, Ai Ming; Lawrence, Khek Yu; Maydeo, Amit

    2015-01-01

    Background: EUS-guided biliary drainage (EUS-BD) has emerged as an alternative rescue method in patients with failed ERCP. Opportunities for teaching and training are limited because of a low case volume at most centers. Objective: To evaluate a stereolithography/3-dimensional (3D) printing bile

  12. Comparative study of ultrasonography, computed tomography, magnetic resonance imaging, and magnetic resonance spectroscopy for the diagnosis for fatty liver in a rat model

    International Nuclear Information System (INIS)

    Noh, Hoon; Song, Xiao Li; Heo, Suk Hee; Kim, Jin Woong; Jeong, Yong Yeon; Kang, Heoung Keun; Shin, Sang Soo; Ahn, Kyu Youn

    2017-01-01

    To compare the accuracy of ultrasonography (US), single-energy CT (SECT), dual-energy CT (DECT), MR imaging (MRI), and MR spectroscopy (MRS) for detecting fatty liver in a rat model. Fatty liver was induced by 60% high-fat diet for 1, 2, 3, 4, or 5 weeks (3 rats per group, a total of 15 rats). The control group comprised of five rats fed 10% high-fat diet. US, SECT, DECT, MRI, and MRS of the liver were performed weekly. Histologic steatosis grade and intrahepatocelluar triglyceride level were determined histologically for the livers of sacrificed rats. Pearson correlation test was used to assess the correlation between examinations and standard reference levels. Receiver operating characteristic curves were constructed. Area under the curve (AUC), sensitivity, and specificity were calculated. US, SECT, DECT, MRI, and MRS were significantly correlated with histologic steatosis grade. The diagnostic performance of AUC, sensitivity, and specificity were 0.893, 80%, and 80% for US, 0.960, 80%, and 80% for SECT, 0.947, 100%, and 60% for DECT, 0.933, 93.3%, and 100% for MRI, and 0.960, 93.3%, and 100% for MRS. MRS showed the strongest correlation with histologic steatosis grade with the highest sensitivity and specificity for diagnosis of fatty liver compared to other modalities

  13. Comparative study of ultrasonography, computed tomography, magnetic resonance imaging, and magnetic resonance spectroscopy for the diagnosis for fatty liver in a rat model

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Hoon; Song, Xiao Li; Heo, Suk Hee; Kim, Jin Woong; Jeong, Yong Yeon; Kang, Heoung Keun [Dept. of Radiology, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of); Shin, Sang Soo [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Ahn, Kyu Youn [Dept. of Anatomy, Chonnam National University Medical School, Gwangju (Korea, Republic of)

    2017-01-15

    To compare the accuracy of ultrasonography (US), single-energy CT (SECT), dual-energy CT (DECT), MR imaging (MRI), and MR spectroscopy (MRS) for detecting fatty liver in a rat model. Fatty liver was induced by 60% high-fat diet for 1, 2, 3, 4, or 5 weeks (3 rats per group, a total of 15 rats). The control group comprised of five rats fed 10% high-fat diet. US, SECT, DECT, MRI, and MRS of the liver were performed weekly. Histologic steatosis grade and intrahepatocelluar triglyceride level were determined histologically for the livers of sacrificed rats. Pearson correlation test was used to assess the correlation between examinations and standard reference levels. Receiver operating characteristic curves were constructed. Area under the curve (AUC), sensitivity, and specificity were calculated. US, SECT, DECT, MRI, and MRS were significantly correlated with histologic steatosis grade. The diagnostic performance of AUC, sensitivity, and specificity were 0.893, 80%, and 80% for US, 0.960, 80%, and 80% for SECT, 0.947, 100%, and 60% for DECT, 0.933, 93.3%, and 100% for MRI, and 0.960, 93.3%, and 100% for MRS. MRS showed the strongest correlation with histologic steatosis grade with the highest sensitivity and specificity for diagnosis of fatty liver compared to other modalities.

  14. Comparison of transhepatic and extrahepatic routes for EUS-guided rendezvous procedure for distal CBD obstruction.

    Science.gov (United States)

    Dhir, Vinay; Bhandari, Suryaprakash; Bapat, Mukta; Joshi, Nitin; Vivekanandarajah, Suhirdan; Maydeo, Amit

    2013-04-01

    EUS-guided rendezvous procedure (EUS-RV) can be done by the transhepatic (TH) or the extrahepatic (EH) route. There is no data on the preferred access route when both routes are available. To compare the success, complications, and duration of hospitalization for patients undergoing EUS-RV by the TH or the EH route. Patients with distal common bile duct (CBD) obstruction, who failed selective cannulation, underwent EUS-RV by the TH route through the stomach or the EH route through the duodenum. A total of 35 patients were analysed (17 TH, 18 EH). The mean procedure time was significantly longer for the TH group (34.4 vs. 25.7 min; p = 0.0004). There was no difference in the technical success (94.1 vs. 100%). However, the TH group had a higher incidence of post-procedure pain (44.1 vs. 5.5%; p = 0.017), bile leak (11.7 vs. 0; p = 0.228), and air under diaphragm (11.7 vs. 0; p = 0.228). All bile leaks were small and managed conservatively. Duration of hospitalization was significantly higher for the TH group (2.52 vs. 0.17 days; p = 0.015). EUS-RV has similar success rate by the TH or the EH route. However, the TH route has higher post-procedure pain, longer procedure time, and longer duration of hospitalization. The EH route should be preferred for EUS-RV in patients with distal CBD obstruction when both access routes are technically feasible.

  15. Ultrasonography in gastroenterology.

    Science.gov (United States)

    Ødegaard, Svein; Nesje, Lars B; Hausken, Trygve; Gilja, Odd Helge

    2015-06-01

    Ultrasonography (US) is a safe and available real-time, high-resolution imaging method, which during the last decades has been increasingly integrated as a clinical tool in gastroenterology. New US applications have emerged with enforced data software and new technical solutions, including strain evaluation, three-dimensional imaging and use of ultrasound contrast agents. Specific gastroenterologic applications have been developed by combining US with other diagnostic or therapeutic methods, such as endoscopy, manometry, puncture needles, diathermy and stents. US provides detailed structural information about visceral organs without hazard to the patients and can play an important clinical role by reducing the need for invasive procedures. This paper presents different aspects of US in gastroenterology, with a special emphasis on the contribution from Nordic scientists in developing clinical applications.

  16. Agreement of duplex ultrasonography vs. computed tomography angiography for evaluation of native and in-stent SFA re-stenosis—Findings from a randomized controlled trial

    International Nuclear Information System (INIS)

    Langenberger, Herbert; Schillinger, Martin; Plank, Christina; Sabeti, Schila; Dick, Petra; Cejna, Manfred; Lammer, Johannes; Minar, Erich; Loewe, Christian

    2012-01-01

    Background: Multidetector CT angiography (CTA) is a non-invasive imaging technique for evaluation of peripheral vascular disease. CTA might be particularly useful for assessment of intermediate- and long-term morphological outcome after endovascular treatment. Validation of CTA vs. the current imaging standard, colour Doppler ultrasonography (CDUS), for quantification of native and in-stent re-stenosis in the superficial femoral artery (SFA) is required. Methods: Seventy randomized patients who underwent stent implantation (n = 47) or balloon angioplasty (n = 23) underwent 6-month follow-up with CDUS and CTA. CTA was compared with CDUS in both sub-groups of patients in terms of binary re-stenosis (>50% lumen narrowing) and re-occlusion. Agreement between CTA and CDUS was assessed using Kappa (κ) statistics with 95% confidence intervals, and correlation coefficients. Results: Binary re-stenosis was detected in 16/70 (22.9%) patients by CTA and 17/70 (24.3%) patients by CDUS (κ = 0.88, 95% CI: 0.80–0.96). Re-stenosis rates after balloon angioplasty were 39.1% (9/23) on CTA and CDUS (κ = 0.82, 95% CI: 0.66–0.98), and after stent implantation 14.9% (7/47) on CTA and 17.0% (8/47) on CDUS (κ = 0.92, 95% CI: 0.84–1.00). Re-occlusions were detected in 3/70 (4.3%) patients by both CTA and CDUS (κ = 0.65; 95% CI 0.54–0.76). Significant correlations (r = 0.85, p < 0.001) were noted between degree of re-stenosis on CTA and peak velocity ratio on CDUS. The correlation coefficient was higher in patients after balloon angioplasty (r = 0.94, p < 0.001) than in patients after stent implantation (r = 0.71, p < 0.001). Conclusion: CTA and CDUS show excellent agreement for evaluation of native and in-stent re-stenosis after endovascular treatment of SFA obstructions. CTA is an appropriate non-invasive imaging modality for follow-up after endovascular therapy

  17. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer.

    Science.gov (United States)

    Konge, L; Vilmann, P; Clementsen, P; Annema, J T; Ringsted, C

    2012-10-01

    Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was to explore the reliability and validity of a newly developed EUS Assessment Tool (EUSAT) designed to measure competence in EUS - FNA for mediastinal staging of NSCLC. A total of 30 patients with proven or suspected NSCLC underwent EUS - FNA for mediastinal staging by three trainees and three experienced physicians. Their performances were assessed prospectively by three experts in EUS under direct observation and again 2 months later in a blinded fashion using digital video-recordings. Based on the assessments, intra-rater reliability, inter-rater reliability, and construct validity were explored. The intra-rater reliability was good (Cronbach's α = 0.80), but comparison of results based on direct observations and blinded video-recordings indicated a significant bias favoring consultants (P = 0.022). Inter-rater reliability was very good (Cronbach's α = 0.93). However, one rater assessing five procedures or two raters each assessing four procedures were necessary to secure a generalizability coefficient of 0.80. The assessment tool demonstrated construct validity by discriminating between trainees and experienced physicians (P = 0.034). Competency in mediastinal staging of NSCLC using EUS and EUS - FNA can be assessed in a reliable and valid way using the EUSAT assessment tool. Measuring and defining competency and training requirements could improve EUS quality and benefit patient care. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Surgeon-performed ultrasonography.

    Science.gov (United States)

    Todsen, Tobias

    2017-11-01

    Surgeons are increasingly using ultrasonography (US) in their clinical management of patients. However, US is a very user-dependent imaging modality and proper skills of the US operator are needed to ensure quality in patient care. This thesis explores the validity evidence for assessment of competence in abdominal and head & neck ultrasonography using the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale. With the use of Messick's unitary framework of validity, five sources of validity evidence were explored: test content, response processes, inter-nal structure, relations to other variables, and consequences. Research paper I examined validity evidence for the use of the OSAUS scale to assess physicians' abdominal point-of-care US competence in an experimental setting using patient cases with and without pathological conditions. The RESULTS provided validity evidence of the internal structure of the OSAUS scale and a deci-sion study predicted that four cases and two raters or five cases and one rater could ensure sufficient reliability in future test setups. The relation to other variables was supported by a signifi-cant difference in scores between US experience levels, and by a strong correlation between the OSAUS score and diagnostic accuracy. Research paper II explored the transfer of learning from formal point-of-care US training to performance on patients in a randomized controlled study. The RESULTS supported validity evi-dence regarding OSAUS scores' relation to other variables by demonstrating a significant discrimination in the progress of training-a more refined validity evidence than the relation to difference experience levels. The RESULTS showed that physicians could transfer the skills learned on an ultrasonography course to improved US performance and diagnostic accuracy on patients. However, the RESULTS also indicated that following an initial course, additional training is needed for physicians to achieve competence in US

  19. Neutron Scattering from Heisenberg Ferromagnets EuO and EuS

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage; Dietrich, O. W.; Passell, L.

    1976-01-01

    Neutron scattering has been used to study the magnetic ordering process in the isotropic exchange coupled ferromagnets EuO and EuS. Quantities investigated include the critical coefficients B and F+ and the critical exponents β, ν, and γ describing respectively the temperature dependence...

  20. Feasibility Study of EUS-NOTES as a Novel Approach for Pancreatic Cancer Staging and Therapy

    DEFF Research Database (Denmark)

    Săftoiu, Adrian; Bhutani, Manoop S; Vilmann, Peter

    2012-01-01

    -guided transgastric approach was tested for ease of access to the tail of the pancreas. Gastric wound closure was finally performed in several animals using various commercial and prototype endoscopic accessories. Results: The results showed the ability of EUS-NOTES technology to facilitate a transgastric approach...

  1. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, Jean-Marc; Deprez, Pierre H; Jenssen, Christian

    2017-01-01

    For pancreatic solid lesions, ESGE recommends performing endoscopic ultrasound (EUS)-guided sampling as first-line procedure when a pathological diagnosis is required. Alternatively, percutaneous sampling may be considered in metastatic disease.Strong recommendation, moderate quality evidence.In ...

  2. EUS-FNA for the Diagnosis of Retroperitoneal Primitive Neuroectodermal Tumor

    Directory of Open Access Journals (Sweden)

    Aijaz A. Sofi

    2011-01-01

    Full Text Available Primitive neuroectodermal tumor (PNET is a rare “small round blue cell tumor” that is diagnosed by open biopsy or percutaneous biopsy of the lesion under radiologic guidance. In this case report, we present a novel approach to the diagnosis of a retroperitoneal PNET by endoscopic ultrasound- (EUS- guided fine needle aspiration (FNA. A 35-year-old man presented with the history of left-sided flank pain and swelling of 3-weeks duration. Computerized tomography (CT scan of his abdomen revealed a 12.8 × 13 × 12.5 cm cystic and solid mass arising from the retroperitoneum and displacing the third and fourth portions of the duodenum. He underwent EUS which revealed a well-circumscribed heterogeneous mass abutting the inferior portion of the stomach. EUS-FNA of the mass revealed malignant cells consistent with primitive neuroectodermal tumor (PNET/Ewing's sarcoma. EUS-guided FNA is an appropriate technique for diagnosing retroperitoneal PNET/Ewing's sarcoma.

  3. Traumatic Lumbar Hernia Diagnosed by Ultrasonography: A Case Report

    International Nuclear Information System (INIS)

    Lee, Kwang Lae; Yim, Yoon Myung; Lim, Oh Kyung; Park, Ki Deok; Choi, Chung Hwan; Lee, Ju Kang

    2009-01-01

    Traumatic lumbar hernia describes the extrusion of intraperitoneal or extraperitoneal contents through a defect in the posterolateral abdominal wall caused by a trauma. This is a rare entity and usually diagnosed by computed tomography. A 64-year-old male received an injury on his cervical spinal cord after an accident in which he fell down. He complained of a mass on his left posterolateral back area. We diagnosed the mass as a traumatic lumbar hernia by ultrasonography and confirmed it by computed tomography. We conclude that the ultrasonography can be a useful diagnostic tool for traumatic lumbar hernia

  4. Traumatic Lumbar Hernia Diagnosed by Ultrasonography: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang Lae; Yim, Yoon Myung; Lim, Oh Kyung; Park, Ki Deok; Choi, Chung Hwan; Lee, Ju Kang [Gachon University of Medicine and Science, Incheon (Korea, Republic of)

    2009-12-15

    Traumatic lumbar hernia describes the extrusion of intraperitoneal or extraperitoneal contents through a defect in the posterolateral abdominal wall caused by a trauma. This is a rare entity and usually diagnosed by computed tomography. A 64-year-old male received an injury on his cervical spinal cord after an accident in which he fell down. He complained of a mass on his left posterolateral back area. We diagnosed the mass as a traumatic lumbar hernia by ultrasonography and confirmed it by computed tomography. We conclude that the ultrasonography can be a useful diagnostic tool for traumatic lumbar hernia

  5. Transthoracic Ultrasonography for Clinicians

    Directory of Open Access Journals (Sweden)

    Morné Johan Vorster

    2015-04-01

    Full Text Available Transthoracic ultrasonography (US has become an essential tool for respiratory, emergency, and critical care physicians. It can be performed with basic equipment and by personnel with minimum training as a modality for the evaluation of a wide range of thoracic pathologies. Its advantages include immediate application at the point of care, low cost, and lack of radiation. The main indications for transthoracic US are the qualitative and quantitative assessment of pleural effusions, pleural thickening, diaphragmatic pathology, as well as chest wall and pleural tumors. Transthoracic US is also useful in visualizing pulmonary pathologies that abut the pleura, such as pneumonic consolidation and interstitial syndromes, including pulmonary edema. Transthoracic US is more sensitive than the traditional chest radiograph in the detection of pneumothoraces, and it is useful in diagnosing skeletal abnormalities such as rib fractures. It is the ideal tool to guide transthoracic procedures, including thoracocentesis and pleural biopsy. Moreover, transthoracic US-guided procedures can be performed by a single clinician with no sedation and minimal monitoring. Transthoracic US-guided fine needle aspiration and/or cutting needle biopsy of extrathoracic lymph nodes and lesions arising from the chest wall, pleura, peripheral lung, and mediastinum are safe to perform and have a high yield in the of hands of experienced clinicians. Transthoracic US can also potentially guide the aspiration and biopsy of diffuse pulmonary infiltrates, consolidations, and lung abscesses. Moreover, transthoracic US may be used in the detection of pulmonary embolism

  6. Advances in diagnostic ultrasonography.

    Science.gov (United States)

    Reef, V B

    1991-08-01

    A wide variety of ultrasonographic equipment currently is available for use in equine practice, but no one machine is optimal for every type of imaging. Image quality is the most important factor in equipment selection once the needs of the practitioner are ascertained. The transducer frequencies available, transducer footprints, depth of field displayed, frame rate, gray scale, simultaneous electrocardiography, Doppler, and functions to modify the image are all important considerations. The ability to make measurements off of videocassette recorder playback and future upgradability should be evaluated. Linear array and sector technology are the backbone of equine ultrasonography today. Linear array technology is most useful for a high-volume broodmare practice, whereas sector technology is ideal for a more general equine practice. The curved or convex linear scanner has more applications than the standard linear array and is equipped with the linear array rectal probe, which provides the equine practitioner with a more versatile unit for equine ultrasonographic evaluations. The annular array and phased array systems have improved image quality, but each has its own limitations. The new sector scanners still provide the most versatile affordable equipment for equine general practice.

  7. Fluid collection after partial pancreatectomy: EUS drainage and long-term follow-up.

    Science.gov (United States)

    Caillol, Fabrice; Godat, Sebastien; Turrini, Olivier; Zemmour, Christophe; Bories, Erwan; Pesenti, Christian; Ratone, Jean Phillippe; Ewald, Jacques; Delpero, Jean Robert; Giovannini, Marc

    2018-03-29

    Postoperative fluid collection due to pancreatic leak is the most frequent complication after pancreatic surgery. Endoscopic ultrasound (EUS)-guided drainage of post-pancreatic surgery fluid collection is the gold standard procedure; however, data on outcomes of this procedure are limited. The primary endpoint of our study was relapse over longterm followup, and the secondary endpoint was the efficiency and safety of EUS-guided drainage of post-pancreatic surgery fluid collection. This retrospective study was conducted at a single center from December 2008 to April 2016. Global morbidity was defined as the occurrence of an event involving additional endoscopic procedures, hospitalization, or interventional radiologic or surgical procedures. EUS-guided drainage was considered a clinical failure if surgery was required to treat a relapse after stent removal. Fortyone patients were included. The technical success rate was 100%. Drainage was considered a clinical success in 93% (39/41) of cases. Additionally, 19 (46%) complications were identified as global morbidity. The duration between surgery and EUS-guided drainage was not a significantly related factor for morbidity rate (P = 0.8); however, bleeding due to arterial injuries (splenic artery and gastroduodenal artery) from salvage drainage procedures occurred within 25 days following the initial surgery. There was no difference in survival between patients with and without complications. No relapse was reported during the followup (median: 44.75 months; range: 29.24 to 65.74 months). EUSguided drainage for post-pancreatic surgery fluid collection was efficient with no relapse during longterm followup. Morbidity rate was independent of the duration between the initial surgery and EUS-guided drainage; however, bleeding risk was likely more important in cases of early drainage.

  8. Primary muscular hydatid: preoperative diagnosis Throught computerized tomography and ultrasonography

    International Nuclear Information System (INIS)

    Macho Fernandez, J.M.; Marin Cardenas, M.A.; Mazas Artasona, L.; Lample Lacasa, C.; Otero Sierra, C.; Hernandez Navarrete, M.J.; Gomez-Pereda, R.

    1995-01-01

    Primary muscular hydatid disease, is extremely rare,- but not exceptional-, comparatively with other atypical localization. In this article the authors revised 474 patients with hydatid disease over a ten years period. Three cases of primary muscular localization were found. The ultrasonography and computed tomography facilitates the preoperative diagnosis. (Author) 40 refs

  9. Quantification of Hepatorenal Index for Computer-Aided Fatty Liver Classification with Self-Organizing Map and Fuzzy Stretching from Ultrasonography

    Directory of Open Access Journals (Sweden)

    Kwang Baek Kim

    2015-01-01

    Full Text Available Accurate measures of liver fat content are essential for investigating hepatic steatosis. For a noninvasive inexpensive ultrasonographic analysis, it is necessary to validate the quantitative assessment of liver fat content so that fully automated reliable computer-aided software can assist medical practitioners without any operator subjectivity. In this study, we attempt to quantify the hepatorenal index difference between the liver and the kidney with respect to the multiple severity status of hepatic steatosis. In order to do this, a series of carefully designed image processing techniques, including fuzzy stretching and edge tracking, are applied to extract regions of interest. Then, an unsupervised neural learning algorithm, the self-organizing map, is designed to establish characteristic clusters from the image, and the distribution of the hepatorenal index values with respect to the different levels of the fatty liver status is experimentally verified to estimate the differences in the distribution of the hepatorenal index. Such findings will be useful in building reliable computer-aided diagnostic software if combined with a good set of other characteristic feature sets and powerful machine learning classifiers in the future.

  10. Transvaginal ultrasonography of rectal endometriosis

    DEFF Research Database (Denmark)

    Egekvist, Anne Gisselmann; Seyer-Hansen, Mikkel; Forman, Axel

    Objectives: The aim of this present study was to evaluate the interobserver variation of transvaginal ultrasonographic measurements of endometriosis infiltrating the rectosigmoid wall. Methods: Transvaginal ultrasonography was performed independently by two observers. Observer 1 had several years...... of experience in ultrasonography while observer 2 was a medical student with no prior experience in ultrasonography or endometriosis. In 24 patient length, width and depth of endometriosis infiltrating the rectosigmoid bowel was measured. The differences between the observers were analysed by Bland and Altman...... for a relatively short period gives comparable scanning results between the two observers. It seems that transvaginal ultrasound could be used as a diagnostic tool for rectal endometriosis in most departments. However, the irregular morphology of the lesions makes the measurements very complex, and a strict...

  11. Ultrasonography of the equine shoulder

    International Nuclear Information System (INIS)

    Dik, K.J.

    1996-01-01

    Six horses with shoulder injuries were presented in this report with emphasis on the use of ultrasonography vs. radiography in diagnosis. The two imaging modalities represented valuable and complementary diagnostic procedures. Two horses had fracture fragments of the lateral humeral tuberosity, the accurate ultrasonographic findings encouraging clearer radiographic identification by oblique projections. In one horseultrasonography enabled more accurate localization of calcification within the supraspinatus muscle. In the remaining three cases ultrasonography visualized distension of the bicipital bursa due to aseptic bursitis, bursal hemorrhage, or associated with injury of the biceps brachii muscle and the underlying intermediate humeral tubercle, the bony involvement more clearly demonstrated radiographically

  12. Endoscopic Ultrasonography in the Diagnosis and Treatment Strategy Choice of Esophageal Leiomyoma.

    Science.gov (United States)

    Sun, Ling-Jia; Chen, Xin; Dai, Yi-Ning; Xu, Cheng-Fu; Ji, Feng; Chen, Li-Hua; Chen, Hong-Tan; Chen, Chun-Xiao

    2017-04-01

    Esophageal leiomyoma is the most common benign tumor of the esophagus, and it originates from mesenchymal tissue. This study analyzed the clinicopathological characteristics of esophageal leiomyoma and aimed to evaluate the role of endoscopic ultrasonography in the diagnosis and treatment selection for these lesions. Two hundred and twenty-five patients who had suspected esophageal leiomyomas in endoscopic ultrasonography were enrolled at the Endoscopy Center of The First Affiliated Hospital, Zhejiang University from January 1st, 2009 to May 31th, 2015. The main outcomes included the demographic and morphological characteristics, symptoms, comparisons of diagnosis and treatment methods, adverse events, and prognosis. One hundred and sixty-seven patients were diagnosed as having an esophageal leiomyoma by pathological examination. The mean patient age was 50.57±9.983 years. In total, 62.9% of the lesions originated from the muscularis mucosa, and the others originated from the muscularis propria. The median distance to the incisors was 30±12 cm. The median diameter was 0.72±0.99 cm. As determined by endoscopic ultrasonography, most existing leiomyomas were homogeneous, endophytic, and spherical. The leiomyomas from the muscularis mucosa were smaller than those from the muscularis propria and much closer to the incisors (pleiomyomas presented less adverse events and better recovery (pleiomyomas. Endoscopic ultrasonography has demonstrated high accuracy in the diagnosis of esophageal leiomyomas and provides great support in selecting treatments; however, EUS cannot completely avoid misdiagnosis, so combining it with other examinations may be a good strategy to solve this problem.

  13. Endoscopic Ultrasonography in the Diagnosis and Treatment Strategy Choice of Esophageal Leiomyoma

    Directory of Open Access Journals (Sweden)

    Ling-Jia Sun

    Full Text Available OBJECTIVES: Esophageal leiomyoma is the most common benign tumor of the esophagus, and it originates from mesenchymal tissue. This study analyzed the clinicopathological characteristics of esophageal leiomyoma and aimed to evaluate the role of endoscopic ultrasonography in the diagnosis and treatment selection for these lesions. METHODS: Two hundred and twenty-five patients who had suspected esophageal leiomyomas in endoscopic ultrasonography were enrolled at the Endoscopy Center of The First Affiliated Hospital, Zhejiang University from January 1st, 2009 to May 31th, 2015. The main outcomes included the demographic and morphological characteristics, symptoms, comparisons of diagnosis and treatment methods, adverse events, and prognosis. RESULTS: One hundred and sixty-seven patients were diagnosed as having an esophageal leiomyoma by pathological examination. The mean patient age was 50.57±9.983 years. In total, 62.9% of the lesions originated from the muscularis mucosa, and the others originated from the muscularis propria. The median distance to the incisors was 30±12 cm. The median diameter was 0.72±0.99 cm. As determined by endoscopic ultrasonography, most existing leiomyomas were homogeneous, endophytic, and spherical. The leiomyomas from the muscularis mucosa were smaller than those from the muscularis propria and much closer to the incisors (p<0.05. SMA (smooth muscle antibody (97.2% and desmin (94.5% were positive in the majority of patients. In terms of treatments, patients preferred endoscopic therapies, which led to less adverse events (e.g., intraoperative bleeding, local infection, pleural effusion than surgical operations (p<0.05. The superficial leiomyomas presented less adverse events and better recovery (p<0.05 than deep leiomyomas. CONCLUSION: Endoscopic ultrasonography has demonstrated high accuracy in the diagnosis of esophageal leiomyomas and provides great support in selecting treatments; however, EUS cannot completely

  14. ULTRASONOGRAPHY AND COMPUTED TOMOGRAPHY GUIDED FINE NEEDLE ASPIRATION CYTOLOGY IN DIAGNOSING INTRA-ABDOMINAL LESIONS- A 6-YEAR RETROSPECTIVE STUDY IN A TERTIARY CARE HOSPITAL IN MANIPUR

    Directory of Open Access Journals (Sweden)

    Ratan Konjengbam

    2017-07-01

    Full Text Available BACKGROUND Fine-Needle Aspiration Cytology (FNAC is a widely used method, which is accurate and safe in a readily palpable masses. But, in those inaccessible lesions and deeper organs are safely aspirated using fine needle radiological procedure like ultrasound or computed tomography guided. The aim of the study is to assess the utility of FNAC in the diagnosis of intra-abdominal lesions and different pattern of lesions in particular to the sites. MATERIALS AND METHODS This retrospective study was done in the Department of Pathology, Regional Institute of Medical Sciences (RIMS, Imphal, between June 2010 and June 2016. The study included 128 intra-abdominal masses. Giemsa and Papanicolaou’s stains were used. The cytological diagnosis was correlated with clinical and radiological data to arrive at a final diagnosis. RESULTS Reports on FNAC smears were retrospectively analysed, which had been done in various anatomic sites- liver (70 cases, colon (19 cases, gallbladder (17 cases, mesenteric lymph nodes (12 cases, ovary (3 cases, adrenals (2 cases and 1 case each of pancreas, peritoneal wall, pelvic, suprapubic and flank masses. The mean age was 42.16 years with M:F of 1.3:1. The diagnostic yield was 85.2% in combination for Ultrasound Guided (USG and Computed Tomography (CT guided aspiration. The smears were classified as benign neoplastic, malignant neoplastic, non-neoplastic, inconclusive and unsatisfactory for interpretation. There were 79 (61.7% malignant neoplastic lesion, 5 (3.9% benign neoplastic lesion, 25 (19.5% non-neoplastic lesion, one (0.7% inconclusive lesions and 18 (14.1% unsatisfactory smears. The liver and the colon were the most common sites. Adenocarcinomas and Hepatocellular Carcinoma (HCC were the most common malignant lesions comprising of 35 (44.3% and 25 (31.6% of the total malignant lesions diagnosed. CONCLUSION Intra-abdominal FNA is a simple, economical and a safe procedure with high sensitivity, specificity and

  15. Geometric programming facilities of EusLisp and assembly goal planner

    International Nuclear Information System (INIS)

    Matsui, Toshihiro; Sakane, Shigeyuki; Hirukawa, Hirohisa

    1994-01-01

    For robots in power plants to accomplish intelligent tasks such as maintenance, inspection, and assembly, the robots must have planning capabilities based on shape models of the environment. Such shape models are defined and manipulated by a program called a geometric modeler or a solid modeler. Although there are commercial solid modelers in the market, they are not always suitable for robotics research, since it is hard to integrate higher level planning functions which frequently access internal model representation. In order to accelerate advanced robotics research, we need a generic, extensible, efficient, and integration-oriented geometric modeler. After reviewing available modelers, we concluded that the object-oriented Lisp can be the best implementation language for solid modeling. The next section introduces the programming language, 'EusLisp', tuned for implementing a solid modeler for intelligent robot programming. The design philosophy and the structure and functions of EusLisp are stated. In the following sections, EusLisp's applications, i.e., viewpoint and light-source location planning, derivation of motion constraint, and assembly goal planning, are discussed. (J.P.N.)

  16. Evaluation of liver parenchyma and perfusion using dynamic contrast-enhanced computed tomography and contrast-enhanced ultrasonography in captive green iguanas (Iguana iguana) under general anesthesia.

    Science.gov (United States)

    Nardini, Giordano; Di Girolamo, Nicola; Leopardi, Stefania; Paganelli, Irene; Zaghini, Anna; Origgi, Francesco C; Vignoli, Massimo

    2014-05-13

    Contrast-enhanced diagnostic imaging techniques are considered useful in veterinary and human medicine to evaluate liver perfusion and focal hepatic lesions. Although hepatic diseases are a common occurrence in reptile medicine, there is no reference to the use of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) to evaluate the liver in lizards. Therefore, the aim of this study was to evaluate the pattern of change in echogenicity and attenuation of the liver in green iguanas (Iguana iguana) after administration of specific contrast media. An increase in liver echogenicity and density was evident during CEUS and CECT, respectively. In CEUS, the mean ± SD (median; range) peak enhancement was 19.9% ± 7.5 (18.3; 11.7-34.6). Time to peak enhancement was 134.0 ± 125.1 (68.4; 59.6-364.5) seconds. During CECT, first visualization of the contrast medium was at 3.6 ± 0.5 (4; 3-4) seconds in the aorta, 10.7 ± 2.2 (10.5; 7-14) seconds in the hepatic arteries, and 15 ± 4.5 (14.5; 10-24) seconds in the liver parenchyma. Time to peak was 14.1 ± 3.4 (13; 11-21) and 31 ± 9.6 (29; 23-45) seconds in the aorta and the liver parenchyma, respectively. CEUS and dynamic CECT are practical means to determine liver hemodynamics in green iguanas. Distribution of contrast medium in iguana differed from mammals. Specific reference ranges of hepatic perfusion for diagnostic evaluation of the liver in iguanas are necessary since the use of mammalian references may lead the clinician to formulate incorrect diagnostic suspicions.

  17. Is Contrast Enhanced Ultrasonography a useful tool in a beginner's hand? How much can a Computer Assisted Diagnosis prototype help in characterizing the malignancy of focal liver lesions?

    Science.gov (United States)

    Moga, Tudor Voicu; Popescu, Alina; Sporea, Ioan; Danila, Mirela; David, Ciprian; Gui, Vasile; Iacob, Nicoleta; Miclaus, Gratian; Sirli, Roxana

    2017-08-23

    Contrast enhanced ultrasound (CEUS) improved the characterization of focal liver lesions (FLLs), but is an operatordependent method. The goal of this paper was to test a computer assisted diagnosis (CAD) prototype and to see its benefit in assisting a beginner in the evaluation of FLLs. Our cohort included 97 good quality CEUS videos[34% hepatocellular carcinomas (HCC), 12.3% hypervascular metastases (HiperM), 11.3% hypovascular metastases (HipoM), 24.7% hemangiomas (HMG), 17.5% focal nodular hyperplasia (FNH)] that were used to develop a CAD prototype based on an algorithm that tested a binary decision based classifier. Two young medical doctors (1 year CEUS experience), two experts and the CAD prototype, reevaluated 50 FLLs CEUS videos (diagnosis of benign vs. malignant) first blinded to clinical data, in order to evaluate the diagnostic gap beginner vs. expert. The CAD classifier managed a 75.2% overall (benign vs. malignant) correct classification rate. The overall classification rates for the evaluators, before and after clinical data were: first beginner-78%; 94%; second beginner-82%; 96%; first expert-94%; 100%; second expert-96%; 98%. For both beginners, the malignant vs. benign diagnosis significantly improved after knowing the clinical data (p=0.005; p=0,008). The expert was better than the beginner (p=0.04) and better than the CAD (p=0.001). CAD in addition to the beginner can reach the expert diagnosis. The most frequent lesions misdiagnosed at CEUS were FNH and HCC. The CAD prototype is a good comparing tool for a beginner operator that can be developed to assist the diagnosis. In order to increase the classification rate, the CAD system for FLL in CEUS must integrate the clinical data.

  18. Ultrasonography of the Rotator Cuff

    International Nuclear Information System (INIS)

    Yoon, Yong Cheol

    2006-01-01

    The ultrasonography (US) is an important modality in evaluating shoulder disease. It is accurate in diagnosing the various shoulder diseases including tendinosis, calcific tendinitis, and subacromial bursitis as well as rotator cuff tears. This article presents a pictorial review of US anatomy of the shoulder, the technical aspects of shoulder US, major types of shoulder pathology, and interventional procedure under US guidance

  19. Ultrasonography of the Rotator Cuff

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yong Cheol [Samsung Medica Center, Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of)

    2006-09-15

    The ultrasonography (US) is an important modality in evaluating shoulder disease. It is accurate in diagnosing the various shoulder diseases including tendinosis, calcific tendinitis, and subacromial bursitis as well as rotator cuff tears. This article presents a pictorial review of US anatomy of the shoulder, the technical aspects of shoulder US, major types of shoulder pathology, and interventional procedure under US guidance

  20. Ovarian torsion: Case–control study comparing the sensitivity and specificity of ultrasonography and computed tomography for diagnosis in the emergency department

    International Nuclear Information System (INIS)

    Swenson, David W.; Lourenco, Ana P.; Beaudoin, Francesca L.; Grand, David J.; Killelea, Alison G.; McGregor, Alyson J.

    2014-01-01

    Objective: Evaluate the sensitivity and specificity of pelvic ultrasound (US) and abdominopelvic computed tomography (CT) for the identification of ovarian torsion in women presenting to the emergency department with acute lower abdominal or pelvic pain. Materials and methods: This is a retrospective study of 20 cases of ovarian torsion and 20 control patients, all of whom had both US and CT performed in the emergency department. Two radiologists who were blinded to clinical data interpreted all studies as (1) demonstrating an abnormal ovary or not, and (2) suggestive of torsion or not. Sensitivity, specificity and interobserver variation were calculated for each imaging modality. Results: Pelvic US was interpreted as demonstrating an abnormal ovary in 90.0% of ovarian torsion cases by reader 1, and in 100.0% by reader 2, whereas CT was interpreted as revealing an abnormal ovary in 100.0% of torsion cases by both readers. Pelvic US for ovarian torsion was 80.0% sensitive (95% CI, 58.4–91.9%) and 95.0% specific (95% CI, 76.4–99.1%) for reader 1, while 80.0% sensitive (95% CI, 58.4–91.9%) and 85.0% specific (95% CI, 64.0–95.0%) for reader 2. Interobserver agreement for pelvic US was fair (Kappa = 0.60). Abdominopelvic CT for ovarian torsion was 100.0% sensitive (95% CI, 83.9–100.0%) and 85.0% specific (95% CI, 64.0–94.5%) for reader 1, while 90.0% sensitive (95% CI, 69.9–97.2%) and 90.0% specific (95% CI, 69.9–97.2%) for reader 2. Interobserver agreement was excellent (Kappa = 0.85). Conclusion: The diagnostic performance of CT is not shown to be significantly different from that of US in identifying ovarian torsion in this study. These results suggest that when CT demonstrates findings of ovarian torsion, the performance of another imaging exam (i.e. US) that delays therapy is unlikely to improve preoperative diagnostic yield

  1. EUS-guided rendezvous for difficult biliary cannulation using a standardized algorithm: a multicenter prospective pilot study (with videos).

    Science.gov (United States)

    Iwashita, Takuji; Yasuda, Ichiro; Mukai, Tsuyoshi; Iwata, Keisuke; Ando, Nobuhiro; Doi, Shinpei; Nakashima, Masanori; Uemura, Shinya; Mabuchi, Masatoshi; Shimizu, Masahito

    2016-02-01

    Biliary cannulation is necessary in therapeutic ERCP for biliary disorders. EUS-guided rendezvous (EUS-RV) can salvage failed cannulation. Our aim was to determine the safety and efficacy of EUS-RV by using a standardized algorithm with regard to the endoscope position in a prospective study. EUS-RV was attempted after failed cannulation in 20 patients. In a standardized approach, extrahepatic bile duct (EHBD) cannulation was preferentially attempted from the second portion of the duodenum (D2) followed by additional approaches to the EHBD from the duodenal bulb (D1) or to the intrahepatic bile duct from the stomach, if necessary. A guidewire was placed in an antegrade fashion into the duodenum. After the guidewire was placed, the endoscope was exchanged for a duodenoscope to complete the cannulation. The bile duct was accessed from the D2 in 10 patients, but from the D1 in 5 patients and the stomach in 4 patients because of no dilation or tumor invasion at the distal EHBD. In the remaining patient, biliary puncture was not attempted due to the presence of collateral vessels. The guidewire was successfully manipulated in 80% of patients: 100% (10/10) with the D2 approach and 66.7% (6/9) with other approaches. The overall success rate was 80% (16/20). Failed EUS-RV was salvaged with a percutaneous approach in 2 patients, repeat ERCP in 1 patient, and conservative management in 1 patient. Minor adverse events occurred in 15% of patients (3/20). EUS-RV is a safe and effective salvage method. Using EUS-RV to approach the EHBD from the D2 may improve success rates. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  2. Screening ultrasonography of 2,204 patients with blunt abdominal trauma in the Wenchuan earthquake.

    Science.gov (United States)

    Zhou, Jixiang; Huang, Jiwei; Wu, Hong; Jiang, Hui; Zhang, Heqing; Prasoon, Pankaj; Xu, Yinglong; Bai, Yannan; Qiu, Jianguo; Zeng, Yong

    2012-10-01

    Abdominal injuries constitute a small proportion of all earthquake-related traumas; however, it often resulted in fatal hemorrhage. Ultrasonography has been described as an effective triage tool in the evaluation of blunt abdominal trauma. We aimed to present an overview of the diagnostic accuracy of screening ultrasonography for patients with blunt abdominal trauma admitted to various hospitals during the Wenchuan earthquake in China. We retrospectively analyzed the patients with blunt abdominal trauma who underwent ultrasonography after admission to various hospitals. Ultrasonography findings were considered positive if evidence of free fluid or a parenchymal injury was identified. Ultrasonography findings were compared with the findings of computed tomography, diagnostic peritoneal lavage, repeated ultrasonography, cystography, operation, and/or the clinical course. Findings from 2,204 ultrasonographic examinations were evaluated. Findings of 199 ultrasonographic examinations (9.0%) were considered positive. Of the patients, 12 (0.5%) had a false-negative ultrasonographic findings; of this group, 3 (25%) required exploratory laparotomy. Ultrasonography had a sensitivity of 91.9%, specificity of 96.9%, and an accuracy of 96.6% for detection of abdominal injuries. Positive predictive value was 68.3%, and negative predictive value was 99.4%. Screening ultrasonography is highly reliable in the setting of blunt abdominal trauma after earthquake. It should be used as an initial diagnostic modality in the evaluation of most blunt abdominal trauma. Diagnostic study, level III.

  3. A prospective study of endoscopic ultrasonography features, cyst fluid carcinoembryonic antigen, and fluid cytology for the differentiation of small pancreatic cystic neoplasms.

    Science.gov (United States)

    Wang, Ying; Chai, Ningli; Feng, Jia; Linghu, Enqiang

    2017-08-24

    With improvements in imaging technologies, pancreatic cystic lesions (PCLs) have been increasingly identified in recent years. However, the imaging modalities used to differentiate the categories of pancreatic cysts remain limited, which may cause confusion when planning treatment. Due to progress in endoscopic ultrasonography-guided fine-needle aspiration (EUS-FNA) technology, auxiliary diagnosis by the detection of cystic fluid has become a recent trend. From March 2015 to April 2016, 120 patients with PCLs were enrolled in this study. According to the results of EUS, cyst fluid carcinoembryonic antigen (CEA) analysis, and cystic fluid cytology, the patients were divided into two groups: a nonmucinous and a mucinous group. Of those, 61 patients who had undergone surgical resection were included in the analysis. The clinical features, biochemical and tumor markers of cyst fluid as well as the cytological test results of the patients were compared with histopathology results. A cyst size of 4.0 cm was used as the boundary value; a cyst ≤4.0 cm was defined as a small PCL. 87 (72.5%) lesions were ≤4.0 cm, and 33 (27.5%) lesions were >4.0 cm. Regarding the analysis of CEA and carbohydrate antigens 19-9 (CA19-9), significant differences were found between the nonmucinous and mucinous groups (P < 0.05) according to nonparametric independent samples tests. The EUS, cystic fluid CEA, and cystic fluid cytology results were compared with the tissue pathology findings using McNemar's test (P < 0.05) and showed a sensitivity of 90% and a specificity of 84%. A diagnostic combination of EUS, cyst fluid CEA, and cystic fluid cytology could be used to differentiate small pancreatic cystic neoplasms. Cystic fluid cytology analysis is helpful for planning treatment for pancreatic cystic tumors that pose a surgical risk.

  4. Diagnostic nerve ultrasonography; Diagnostische Nervensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Baeumer, T. [Universitaet zu Luebeck CBBM, Haus 66, Institut fuer Neurogenetik, Luebeck (Germany); Grimm, A. [Universitaetsklinikum Tuebingen, Klinik und Poliklinik fuer Neurologie, Tuebingen (Germany); Schelle, T. [Staedtisches Klinikum Dessau, Neurologische Klinik, Dessau (Germany)

    2017-03-15

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [German] Fuer die Diagnostik von Nervenlaesionen ist ein bildgebendes Verfahren zur Darstellung des peripheren Nervs und seiner ihn umgebenden Strukturen fuer eine aetiologische Einordnung erforderlich. Mit der klinisch-neurologischen Untersuchung und Elektrophysiologie ist eine funktionelle Aussage ueber die Nervenlaesion moeglich. In der Standard-MRT-Untersuchung wird der periphere Nerv nur unzureichend gut dargestellt. Die MRT-Neurographie ist ein sehr gutes, aber auch zeit- und ressourcenintensives Verfahren. Nutzung des Ultraschalls fuer die

  5. The Effectiveness of Ultrasonography in Detecting Emergent Pediatric Pathologies and Requirement for Additional Imaging Techniques: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    Betül Tiryaki Baştuğ

    2018-04-01

    Full Text Available Introduction: In emergency cases, ultrasonography is used in guiding resuscitation, to provide procedural guidance, and confirm a clinical diagnosis. In addition, it may prevent unnecessary exposure of the patient to ionizing radiation and risks caused by transporting the patient away from monitoring. This paper aimed to evaluate the effectiveness of ultrasonography in detecting emergent pediatric pathologies in a state hospital radiology unit, and to identify whether additional imaging techniques, such as computed tomography, were required. Methods: This study was designed as a retrospective investigation. A group of 536 patients were randomly selected from 1.401 pediatric patients who underwent ultrasonography for non-traumatic emergent pathologies between 2015 and 2016. Results: Of the 536 patients, 46 were diagnosed with appendicitis, 14 with pathologies of the urinary system, 1 with ileus, 29 with mesenteric lymphadenitis, 4 with intussusception, 3 with ovarian cyst rupture, 1 with ovarian torsion, and 32 with scrotal pathologies. Computed tomography was performed for 20 patients. Ureteral calculi and appendicitis were confirmed by computed tomography in 5 and 14 patients, respectively, after being identified as secondary findings by ultrasonography. In 1 patient, ileus was verified by computed tomography. The sensitivity of ultrasonography was determined to be 85.7%. Only 14% of patients were not given definite pathological diagnoses by ultrasonography alone. Subsequent computed tomography for verifying secondary findings detected by ultrasonography was essential in only 20 patients. Conclusion: Our results promote the use of ultrasonography as the initial imaging test for evaluating pediatric patients with suspected emergency pathologies.

  6. Ultrasonography of the canine pancreas

    Directory of Open Access Journals (Sweden)

    Michelle L Avante

    2018-01-01

    Full Text Available This study describes the ultrasonographic techniques currently used in the evaluation of the canine pancreas. Ultrasonography was the first method to enable direct visualization of the pancreas in humans and it has been subsequently applied to animals. Currently, it is the method of choice for pancreatic evaluation and is essential as a diagnostic tool in the detection of abnormalities, especially tumors. Innovative equipment technology has led to the emergence of techniques complementary to B-mode ultrasound; such as Doppler, elastography, and contrast-enhanced ultrasonography, which have enabled more accurate diagnosis. Doppler provides information on vascular architecture and the hemodynamic aspect of blood vessels in multiple organs. ARFI elastography provides detailed images of the alterations detected by conventional examination (qualitative method and assists in differentiating between benign and malignant processes (quantitative method. Microbubble contrast agents determine parameters related to homogeneous and heterogeneous filling of organs with microbubbles, mainly nodular areas, thus defining high and low intensity patterns.

  7. Ultrasonography findings of gastric carcinoma

    International Nuclear Information System (INIS)

    Chung, Chong Ku; Choi, Ji Bai; Ko, Young Tae; Lim, Jae Hoon; Kim, Soon Young

    1985-01-01

    Stomach carcinoma is more common disease in Korea than western countries. The reported ultrasonographic findings of gastric carcinoma were thickening of gastric wall and 'pseudokidney' sign. The author analyzed ultrasonographic findings of 101 cases with gastric carcinoma who were performed ultrasonography and gastroscopy at Kyung Hee University Hospital from October 1982 to October 1985. The results were as followings; 1. Types of gastric carcinoma were consisted with infiltrative type 68 cases, infiltrative type with ulceration 16 cases, polypoid type with ulceration 1 case, infiltrative adn polypoid type 4 cases, limits plastica type 3 cases, ulcerative type 1 case and polypoid type 1 case. 2. Extent of the lesions were in body and antrum 45 cases, entire stomach 18 cases, antrum 18 cases, body 12 cases, body and fundus 6 cases. 3. Ultrasonography was useful in demonstrating the extent of the tumor and the presence of materials elsewhere in abdomen

  8. Ultrasonography findings of gastric carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Chong Ku; Choi, Ji Bai; Ko, Young Tae; Lim, Jae Hoon; Kim, Soon Young [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1985-12-15

    Stomach carcinoma is more common disease in Korea than western countries. The reported ultrasonographic findings of gastric carcinoma were thickening of gastric wall and 'pseudokidney' sign. The author analyzed ultrasonographic findings of 101 cases with gastric carcinoma who were performed ultrasonography and gastroscopy at Kyung Hee University Hospital from October 1982 to October 1985. The results were as followings; 1. Types of gastric carcinoma were consisted with infiltrative type 68 cases, infiltrative type with ulceration 16 cases, polypoid type with ulceration 1 case, infiltrative adn polypoid type 4 cases, limits plastica type 3 cases, ulcerative type 1 case and polypoid type 1 case. 2. Extent of the lesions were in body and antrum 45 cases, entire stomach 18 cases, antrum 18 cases, body 12 cases, body and fundus 6 cases. 3. Ultrasonography was useful in demonstrating the extent of the tumor and the presence of materials elsewhere in abdomen.

  9. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncica, Ana Maria; Saftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...

  10. Abdominal ultrasonography, 2nd Ed

    International Nuclear Information System (INIS)

    Goldberg, B.B.

    1984-01-01

    This volume is a new and updated edition of an extensively illustrated text and reference on the capabilities and imaging of gray scale ultrasonography for each major abdominal organ. Each major organ system is treated separately, including liver, gallbladder and bile ducts, pancreas, kidney, retroperitoneum, abdominal vasculature, and more. There are over 500 illustrations and ten pages of full color plates for cross sectional anatomy

  11. Thyroid ultrasonography: Pitfalls and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seon hyeong; Kim, Eun Kyung; Kim, Soo Jin; Kwak, Jin Young [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-04-15

    Thyroid ultrasonography (US) plays a key role in the diagnosis and management of thyroid-related diseases. The aim of this article was to illustrate various pitfalls that can occur in utilizing thyroid US and techniques to prevent them. In this article, we present cases demonstrating the common pitfalls associated with US equipment, performance, normal thyroid structures, misinterpretations, and surrounding structures. Knowledge of these areas is essential to avoid misdiagnosis or improper disease management.

  12. Utility of 18F-fluoro-deoxyglucose emission tomography/computed tomography fusion imaging (18F-FDG PET/CT) in combination with ultrasonography for axillary staging in primary breast cancer

    International Nuclear Information System (INIS)

    Ueda, Shigeto; Ishida, Jiro; Abe, Yoshiyuki; Mochizuki, Hidetaka; Tsuda, Hitoshi; Asakawa, Hideki; Omata, Jiro; Fukatsu, Kazuhiko; Kondo, Nobuo; Kondo, Tadaharu; Hama, Yukihiro; Tamura, Katsumi

    2008-01-01

    Accurate evaluation of axillary lymph node (ALN) involvement is mandatory before treatment of primary breast cancer. The aim of this study is to compare preoperative diagnostic accuracy between positron emission tomography/computed tomography with 18 F-fluorodeoxyglucose ( 18 F-FDG PET/CT) and axillary ultrasonography (AUS) for detecting ALN metastasis in patients having operable breast cancer, and to assess the clinical management of axillary 18 F-FDG PET/CT for therapeutic indication of sentinel node biopsy (SNB) and preoperative systemic chemotherapy (PSC). One hundred eighty-three patients with primary operable breast cancer were recruited. All patients underwent 18 F-FDG PET/CT and AUS followed by SNB and/or ALN dissection (ALND). Using 18 F-FDG PET/CT, we studied both a visual assessment of 18 F-FDG uptake and standardized uptake value (SUV) for axillary staging. In a visual assessment of 18 F-FDG PET/CT, the diagnostic accuracy of ALN metastasis was 83% with 58% in sensitivity and 95% in specificity, and when cut-off point of SUV was set at 1.8, sensitivity, specificity, and accuracy were 36, 100, and 79%, respectively. On the other hand, the diagnostic accuracy of AUS was 85% with 54% in sensitivity and 99% in specificity. By the combination of 18 F-FDG PET/CT and AUS to the axilla, the sensitivity, specificity, and accuracy were 64, 94, and 85%, respectively. If either 18 F-FDG PET uptake or AUS was positive in allixa, the probability of axillary metastasis was high; 50% (6 of 12) in 18 F-FDG PET uptake only, 80% (4 of 5) in AUS positive only, and 100% (28 of 28) in dual positive. By the combination of AUS and 18 F-FDG PET/CT, candidates of SNB were more appropriately selected. The axillary 18 F-FDG uptake was correlated with the maximum size and nuclear grade of metastatic foci (p = 0.006 and p = 0.03). The diagnostic accuracy of 18 F-FDG PET/CT was shown to be nearly equal to ultrasound, and considering their limited sensitivities, the high radiation

  13. Utility of 18F-fluoro-deoxyglucose emission tomography/computed tomography fusion imaging (18F-FDG PET/CT in combination with ultrasonography for axillary staging in primary breast cancer

    Directory of Open Access Journals (Sweden)

    Tamura Katsumi

    2008-06-01

    Full Text Available Abstract Background Accurate evaluation of axillary lymph node (ALN involvement is mandatory before treatment of primary breast cancer. The aim of this study is to compare preoperative diagnostic accuracy between positron emission tomography/computed tomography with 18F-fluorodeoxyglucose (18F-FDG PET/CT and axillary ultrasonography (AUS for detecting ALN metastasis in patients having operable breast cancer, and to assess the clinical management of axillary 18F-FDG PET/CT for therapeutic indication of sentinel node biopsy (SNB and preoperative systemic chemotherapy (PSC. Methods One hundred eighty-three patients with primary operable breast cancer were recruited. All patients underwent 18F-FDG PET/CT and AUS followed by SNB and/or ALN dissection (ALND. Using 18F-FDG PET/CT, we studied both a visual assessment of 18F-FDG uptake and standardized uptake value (SUV for axillary staging. Results In a visual assessment of 18F-FDG PET/CT, the diagnostic accuracy of ALN metastasis was 83% with 58% in sensitivity and 95% in specificity, and when cut-off point of SUV was set at 1.8, sensitivity, specificity, and accuracy were 36, 100, and 79%, respectively. On the other hand, the diagnostic accuracy of AUS was 85% with 54% in sensitivity and 99% in specificity. By the combination of 18F-FDG PET/CT and AUS to the axilla, the sensitivity, specificity, and accuracy were 64, 94, and 85%, respectively. If either 18F-FDG PET uptake or AUS was positive in allixa, the probability of axillary metastasis was high; 50% (6 of 12 in 18F-FDG PET uptake only, 80% (4 of 5 in AUS positive only, and 100% (28 of 28 in dual positive. By the combination of AUS and 18F-FDG PET/CT, candidates of SNB were more appropriately selected. The axillary 18F-FDG uptake was correlated with the maximum size and nuclear grade of metastatic foci (p = 0.006 and p = 0.03. Conclusion The diagnostic accuracy of 18F-FDG PET/CT was shown to be nearly equal to ultrasound, and considering their

  14. Developing Federated Services within Seismology: IRIS' involvement in the CoopEUS Project

    Science.gov (United States)

    Ahern, T. K.; Trabant, C. M.; Stults, M.

    2014-12-01

    As a founding member of the CoopEUS initiative, IRIS Data Services has partnered with five data centers in Europe and the UC Berkeley (NCEDC) in the US to implement internationally standardized web services to access seismological data using identical methodologies. The International Federation of Digital Seismograph Networks (FDSN) holds commission status within IASPEI/IUGG and as such is the international body that governs data exchange formats and access protocols within seismology. The CoopEUS project involves IRIS and UNAVCO as part of the EarthScope project and the European collaborators are all members of the European Plate Observing System (EPOS). CoopEUS includes one work package that attempts to coordinate data access between EarthScope and EPOS facilities. IRIS has worked with its partners in the FDSN to develop and adopt three key international service standards within seismology. These include 1) fdsn-dataselect, a service that returns time series data in a variety of standard formats, 2) fdsn-station, a service that returns related metadata about a seismic station in stationXML format, and 3) fdsn-event, a service that returns information about earthquakes and other seismic events in QuakeML format. Currently the 5 European data centers supporting these services include the ORFEUS Data Centre in the Netherlands, the GFZ German Research Centre for Geosciences in Potsdam, Germany, ETH Zurich in Switzerland, INGV in Rome, Italy, and the RESIF Data Centre in Grenoble France. Presently these seven centres can all be accessed using standardized web services with identical service calls and returns results in standardized ways. IRIS is developing an IRIS federator that will allow a client to seamlessly access information across the federated centers. Details and current status of the IRIS Federator will be presented.

  15. Induced spin-polarization of EuS at room temperature in Ni/EuS multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Poulopoulos, P., E-mail: poulop@upatras.gr [Laboratory of High-Tech Materials, School of Engineering, University of Patras, 26504 Patras (Greece); Materials Science Department, University of Patras, 26504 Patras (Greece); Goschew, A.; Straub, A.; Fumagalli, P. [Institut für Experimentalphysik, Freie Universität Berlin, Arnimallee 14, D-14195 Berlin-Dahlem (Germany); Kapaklis, V.; Wolff, M. [Department of Physics and Astronomy, Uppsala University, Box 516, SE-751 20 Uppsala (Sweden); Delimitis, A. [Chemical Process and Energy Resources Institute (CPERI), Centre for Research and Technology Hellas (CERTH), 57001 Thermi, Thessaloniki (Greece); Wilhelm, F.; Rogalev, A. [European Synchrotron Radiation Facility (ESRF), B.P.220, 38043 Grenoble (France); Pappas, S. D. [Laboratory of High-Tech Materials, School of Engineering, University of Patras, 26504 Patras (Greece); Department of Physics and Astronomy, Uppsala University, Box 516, SE-751 20 Uppsala (Sweden)

    2014-03-17

    Ni/EuS multilayers with excellent multilayer sequencing are deposited via e-beam evaporation on the native oxide of Si(100) wafers at 4 × 10{sup −9} millibars. The samples have very small surface and interface roughness and show sharp interfaces. Ni layers are nanocrystalline 4–8 nm thick and EuS layers are 2–4 nm thick and are either amorphous or nanocrystalline. Unlike for Co/EuS multilayers, all Eu ions are in divalent (ferromagnetic) state. We show a direct antiferromagnetic coupling between EuS and Ni layers. At room temperature, the EuS layers are spin-polarized due to the proximity of Ni. Therefore, Ni/EuS is a candidate for room-temperature spintronics applications.

  16. Diagnostic performance of EUS in predicting advanced cancer among patients with Barrett's esophagus and high-grade dysplasia/early adenocarcinoma: systematic review and meta-analysis.

    Science.gov (United States)

    Qumseya, Bashar J; Brown, Jessica; Abraham, Merna; White, Donna; Wolfsen, Herbert; Gupta, Neil; Vennalaganti, Prashanth; Sharma, Prateek; Wallace, Michael B

    2015-04-01

    The role of EUS among patients with Barrett's esophagus (BE) with high-grade dysplasia (HGD) or suspected mucosal carcinoma is controversial. To define the role of EUS in detecting advanced disease among patients with BE. Systematic review and meta-analysis. MEDLINE, Embase, Web of Science, and Cochrane Central databases. Patients with BE and HGD or esophageal adenocarcinoma (EAC) who were referred for endoscopic evaluation and underwent EUS. EUS. Pooled proportion of patients with advanced EAC identified by EUS among patients with BE who are referred for HGD or EAC (with or without visible lesions). Forest plots were used to contrast effect sizes in each of the studies and random effect models when tests of heterogeneity were significant (I(2) > 50% or P statistic). Of 1278 articles, 47 were reviewed in full text, and 11 articles met the inclusion criteria, including a total of 656 patients. Based on a random-effects model, the proportion of patients with advanced disease detected on EUS was 14% (95% confidence interval, 8%-22%; P advanced disease on EUS in the absence of nodules was 4% (95% confidence interval, 2%-6%, P < .0001). Significant heterogeneity among studies. EUS will result in a change in the therapeutic approach among in a significant minority of patients with BE who are referred for HGD or EAC. Copyright © 2015. Published by Elsevier Inc.

  17. Endoscopic ultrasound in the evaluation of chronic upper abdominal pain of unknown etiology: a retrospective chart review examining the efficacy of EUS in determining a new diagnosis.

    Science.gov (United States)

    Thompson, Michelle B; Ramirez, Jonathan C; De La Rosa, Lisa M; Wood, Adam S; Desai, Shiv; Arjunan, Ananth; Song, Juhee; Erickson, Richard A

    2015-02-01

    To explore the utility of endoscopic ultrasound (EUS) in the evaluation of chronic upper abdominal pain (UAP) of undetermined etiology. Chronic UAP is a common problem with a challenging diagnosis and management. The role of EUS in the diagnosis of UAP may minimize additional testing; however, few studies describe the percentage of new diagnoses yielded in these patients. We conducted a retrospective analysis by reviewing electronic medical records at Scott and White Memorial Hospital, Texas A&M Health Sciences Center for patients with abdominal pain for ≥ 12 months not explained by previous workup referred for EUS for chronic UAP from January 1, 1998 through October 1, 2007. Patients with previous EUS in past 12 months were excluded from the study. Patient demographic data and imaging performed 6 months before and 24 months after EUS were reviewed and results documented. EUS was successful at diagnosing a new clinical etiology of chronic UAP in 33 patients (8.89%) with previous workup that was unrevealing for a definitive diagnosis. The most frequent diagnoses included pancreaticobiliary tree abnormalities, chronic pancreatitis, and fatty liver disease. Our results support the fact that the majority of patients UAP with prior imaging will have no identifiable organic etiology found on EUS to explain their pain; however, we suggest that EUS be considered in patients with suspected pancreatic or biliary pathology.

  18. Irregular echogenic foci representing coagulation necrosis: a useful but perhaps under-recognized EUS echo feature of malignant lymph node invasion.

    Science.gov (United States)

    Bhutani, Manoop S; Saftoiu, Adrian; Chaya, Charles; Gupta, Parantap; Markowitz, Avi B; Willis, Maurice; Kessel, Ivan; Sharma, Gulshan; Zwischenberger, Joseph B

    2009-06-01

    Coagulation necrosis has been described in malignant lymph nodes. Our aim was to determine if coagulation necrosis in mediastinal lymph nodes imaged by EUS could be used as a useful echo feature for predicting malignant invasion. Patients with known or suspected lung cancer who had undergone mediastinal lymph node staging by EUS. Tertiary Care university hospital. An expert endosonographer blinded to the final diagnosis, reviewed the archived digital EUS images of lymph nodes prior to being sampled by FNA. LNs positive for malignancy by FNA were included. The benign group included lymph node images with either negative EUS-FNA or lymph nodes imaged by EUS but not subjected to EUS-FNA, with surgical correlation of their benign nature. 24 patients were included. 8 patients were found to have coagulation necrosis. 7/8 patients had positive result for malignancy by EUS-FNA. One patient determined to have coagulation necrosis had a non-malignant diagnosis indicating a false positive result. 16 patients had no coagulation necrosis. In 6 patients with no coagulation necrosis, the final diagnosis was malignant and in the remaining 10 cases, the final diagnosis was benign. For coagulation necrosis as an echo feature for malignant invasion, sensitivity was 54%, specificity was 91%, positive predictive value was 88%, negative predictive value was 63% and accuracy was 71%. Coagulation necrosis is a useful echo feature for mediastinal lymph node staging by EUS.

  19. The image of urachus adenocarcinoma on Doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Oyar, Orhan E-mail: o_oyar@hotmail.com; Yesildag, Ahmet; Gulsoy, Ufuk Kemal; Perk, Hakki

    2002-10-01

    Malignant urachal lesions are exceedingly rare and occur predominantly in adult life. In this case report, an adult patient with urachal carcinoma is presented with abdominal plain film, intravenous urography, gray-scale ultrasonography (US), Doppler US, and computed tomography (CT). Doppler US successfully showed the neovascularity with low resistive index value in the urachus tumor. We believe that Doppler US examination is helpful in the differential diagnosis of urachal carcinoma.

  20. SQUID magnetometry and magneto-optics of epitaxial EuS

    International Nuclear Information System (INIS)

    Rumpf, K.; Granitzer, P.; Krenn, H.; Kellner, W.; Pascher, H.; Kirchschlager, R.; Janecek, S.

    2004-01-01

    The complicated (H,T)-magnetic phase diagram of EuS is caused by the critical balance between nearest and next nearest neighbour exchange interaction (J NN = 0.119 K and J NNN =-0.1209 K) and leads to various spin arrangements NNSS..., NSN..., NNS, NNN... [NS denotes opposite ferromagnetic order in adjacent (111) planes]. Beside the subtle local exchange of 5d-t 2g electrons and localized holes with neighbouring Eu-4f spins, obviously also the strain status influences the occurrence of these different phases. We investigate the magnetic ordering phenomenon in a strained 2.5 μm EuS film on BaF 2 substrate by SQUID magnetometry and magneto-optics like spectral Faraday- and Kerr-effect measurements for temperatures from 2 K up to 200 K and for magnetic field up to 5 T. The magneto-optical probe monitors the local environment of the photoexcited electron-hole pair, called magnetic exciton, located within a ferromagnetic surrounding (photoinduced magnetic polaron), whereas the integral magnetization measured by SQUID is most sensitive to long-range magnetic ordering. In spite of the dissimilarity of measurement techniques we find an influence of the long-range magnetic order (e.g. of the NNS- or NNN-matrix) on the non-resonant Kerr reflection. The complementarity of SQUID and magneto-optical methods is stringent only in the (resonant) spectral range, where magnetic polarons are formed. (author)

  1. Optical third harmonic generation in the magnetic semiconductor EuSe

    Science.gov (United States)

    Lafrentz, M.; Brunne, D.; Kaminski, B.; Pavlov, V. V.; Pisarev, R. V.; Henriques, A. B.; Yakovlev, D. R.; Springholz, G.; Bauer, G.; Bayer, M.

    2012-01-01

    Third harmonic generation (THG) has been studied in europium selenide EuSe in the vicinity of the band gap at 2.1-2.6 eV and at higher energies up to 3.7 eV. EuSe is a magnetic semiconductor crystalizing in centrosymmetric structure of rock-salt type with the point group m3m. For this symmetry the crystallographic and magnetic-field-induced THG nonlinearities are allowed in the electric-dipole approximation. Using temperature, magnetic field, and rotational anisotropy measurements, the crystallographic and magnetic-field-induced contributions to THG were unambiguously separated. Strong resonant magnetic-field-induced THG signals were measured at energies in the range of 2.1-2.6 eV and 3.1-3.6 eV for which we assign to transitions from 4f7 to 4f65d1 bands, namely involving 5d(t2g) and 5d(eg) states.

  2. International guidelines for contrast-enhanced ultrasonography

    DEFF Research Database (Denmark)

    Nolsøe, Christian Pállson; Lorentzen, Torben

    2016-01-01

    The intent of this review is to discuss and comment on common clinical scenarios in which contrast-enhanced ultrasonography (CEUS) may play a decisive role and to illustrate important points with typical cases. With the advent of CEUS, the scope of indications for ultrasonography has been dramati...

  3. Balanced Propofol Sedation in Patients Undergoing EUS-FNA: A Pilot Study to Assess Feasibility and Safety

    Directory of Open Access Journals (Sweden)

    N. Pagano

    2011-01-01

    Full Text Available Introduction and aims. Balanced propofol sedation (BPS administered by gastroenterologists has gained popularity in endoscopic procedures. Few studies exist about the safety of this approach during endosonography with fine needle aspiration (EUS-FNA. We assessed the safety of BPS in EUS-FNA. Materials and methods. 112 consecutive patients, referred to our unit to perform EUS-FNA, from February 2008 to December 2009, were sedated with BPS. A second gastroenterologist administered the drugs and monitorized the patient. Results. All the 112 patients (62 males, mean age 58.35 completed the examination. The mean dose of midazolam and propofol was, respectively, of 2.1 mg (range 1–4 mg and 350 mg (range 180–400. All patients received oxygen with a mean flux of 4 liter/minute (range 2–6 liters/minute. The mean recovery time after procedure was 25 minutes (range 18–45 minutes. No major complications related to sedation were registered during all procedures. The oxygen saturation of all patients never reduced to less than 85%. Blood systolic pressure during and after the procedure never reduced to less than 100 mmHg. Conclusions. In our experience BPS administered by non-anaesthesiologists provided safe and successful sedation in patients undergoing EUS-FNA.

  4. USES 2.0, The Uniform System for the Evaluation of Substances, version 2.0 ; supplement to EUSES

    NARCIS (Netherlands)

    Linders JBHJ; Jager DT; CSR; ECO

    1997-01-01

    This interim report describes the updated risk assessment system for agricultural and non-agricultural pesticides. It will be integrated with the European Union System for the Evaluation of Substances, EUSES 1.0, into USES 2.0, the second version of the Uniform System for the Evaluation of

  5. USES 2.0, The Uniform System for the Evaluation of Substances, version 2.0 ; supplement to EUSES

    NARCIS (Netherlands)

    Linders JBHJ; Jager DT (eds.); CSR; ECO

    1997-01-01

    Dit interimrapport beschrijft het risicobeoordelingssysteem voor landbouw- en niet-landbouwbestrijdingsmiddelen. Het zal worden geintegreerd met het European Union System for the Evaluation of Substances, EUSES 1.0, tot USES 2.0, de tweede versie van het Uniforme Beoordelingssysteem voor

  6. Multicenter randomized controlled trial comparing the performance of 22 gauge versus 25 gauge EUS-FNA needles in solid masses

    DEFF Research Database (Denmark)

    Vilmann, Peter; S?ftoiu, Adrian; Hollerbach, Stephan

    2013-01-01

    Few randomized studies have assessed the clinical performance of 25-gauge (25G) needles compared with 22-gauge (22G) needles during endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) biopsy of intra-abdominal lesions. We aimed to compare the diagnostic yield, as well as performance...

  7. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncică, Ana Maria; Săftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...... cancers and visualization of the portal venous system and esophageal varices. In addition, contrast agents can be used to differentiate pancreatic lesions. The use of color Doppler further increases the ability to diagnose and differentiate various pancreatic malignancies. The sensitivity of power Doppler...

  8. Diagnostic accuracy of transabdominal high-resolution US for staging gallbladder cancer and differential diagnosis of neoplastic polyps compared with EUS.

    Science.gov (United States)

    Lee, Jeong Sub; Kim, Jung Hoon; Kim, Yong Jae; Ryu, Ji Kon; Kim, Yong-Tae; Lee, Jae Young; Han, Joon Koo

    2017-07-01

    To compare the diagnostic accuracy of transabdominal high-resolution ultrasound (HRUS) for staging gallbladder cancer and differential diagnosis of neoplastic polyps compared with endoscopic ultrasound (EUS) and pathology. Among 125 patients who underwent both HRUS and EUS, we included 29 pathologically proven cancers (T1 = 7, T2 = 19, T3 = 3) including 15 polypoid cancers and 50 surgically proven polyps (neoplastic = 30, non-neoplastic = 20). We reviewed formal reports and assessed the accuracy of HRUS and EUS for diagnosing cancer as well as the differential diagnosis of neoplastic polyps. Statistical analyses were performed using chi-square tests. The sensitivity, specificity, PPV, and NPV for gallbladder cancer were 82.7 %, 44.4 %, 82.7 %, and 44 % using HRUS and 86.2 %, 22.2 %, 78.1 %, and 33.3 % using EUS. HRUS and EUS correctly diagnosed the stage in 13 and 12 patients. The sensitivity, specificity, PPV, and NPV for neoplastic polyps were 80 %, 80 %, 86 %, and 73 % using HRUS and 73 %, 85 %, 88 %, and 69 % using EUS. Single polyps (8/20 vs. 21/30), larger (1.0 ± 0.28 cm vs. 1.9 ± 0.85 cm) polyps, and older age (52.5 ± 13.2 vs. 66.1 ± 10.3 years) were common in neoplastic polyps (p diagnostic accuracy for GB cancer compared with EUS. • HRUS and EUS showed similar diagnostic accuracy for differentiating neoplastic polyps. • Single, larger polyps and older age were common in neoplastic polyps. • HRUS is less invasive compared with EUS.

  9. An international multicenter study comparing EUS-guided pancreatic duct drainage with enteroscopy-assisted endoscopic retrograde pancreatography after Whipple surgery.

    Science.gov (United States)

    Chen, Yen-I; Levy, Michael J; Moreels, Tom G; Hajijeva, Gulara; Will, Uwe; Artifon, Everson L; Hara, Kazuo; Kitano, Masayuki; Topazian, Mark; Abu Dayyeh, Barham; Reichel, Andreas; Vilela, Tiago; Ngamruengphong, Saowanee; Haito-Chavez, Yamile; Bukhari, Majidah; Okolo, Patrick; Kumbhari, Vivek; Ismail, Amr; Khashab, Mouen A

    2017-01-01

    Endoscopic management of post-Whipple pancreatic adverse events (AEs) with enteroscopy-assisted endoscopic retrograde pancreatography (e-ERP) is associated with high failure rates. EUS-guided pancreatic duct drainage (EUS-PDD) has shown promising results; however, no comparative data have been done for these 2 modalities. The goal of this study is to compare EUS-PDD with e-ERP in terms of technical success (PDD through dilation/stent), clinical success (improvement/resolution of pancreatic-type symptoms), and AE rates in patients with post-Whipple anatomy. This is an international multicenter comparative retrospective study at 7 tertiary centers (2 United States, 2 European, 2 Asian, and 1 South American). All consecutive patients who underwent EUS-PDD or e-ERP between January 2010 and August 2015 were included. In total, 66 patients (mean age, 57 years; 48% women) and 75 procedures were identified with 40 in EUS-PDD and 35 in e-ERP. Technical success was achieved in 92.5% of procedures in the EUS-PDD group compared with 20% of procedures in the e-ERP group (OR, 49.3; P procedures in the EUS-PDD group compared with 23.1% in the e-ERP group (OR, 23.3; P Procedure time and length of stay were not significantly different between the 2 groups. EUS-PDD is superior to e-ERP in post-Whipple anatomy in terms of efficacy with acceptable safety. As such, EUS-PDD should be considered as a potential first-line treatment in post-pancreaticoduodenectomy anatomy when necessary expertise is available. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  10. Fatty liver diagnostic from medical examination to analyze the accuracy between the abdominal ultrasonography and liver hounsfield units

    International Nuclear Information System (INIS)

    Oh, Wang Kyun; Kim, Sang Hyun

    2017-01-01

    In abdominal Ultrasonography, the fatty liver is diagnosed through hepatic parenchymal echo increased parenchymal density and unclear blood vessel boundary, and according to many studies, abdominal Ultrasonography has 60 ∼ 90% of sensitivity and 84 ∼ 95% of specificity in diagnosis of fatty liver, but the result of Ultrasonography is dependent on operators, so there can be difference among operators, and quantitative measurement of fatty infiltration is impossible. Among examinees who same day received abdominal Ultrasonography and chest computed tomography (CT), patients who were diagnosed with a fatty liver in the Ultrasonography were measured with liver Hounsfield Units (HU) of chest CT imaging to analyze the accuracy of the fatty liver diagnosis. Among 720 subject examinees, those who were diagnosed with a fatty liver through abdominal Ultrasonography by family physicians were 448, which is 62.2%. The result of Liver HU measurement in the chest CT imaging of those who were diagnosed with a fatty liver showed that 175 out of 720 had the measured value of less than 40 HU, which is 24.3%, and 173 were included to the 175 among 448 who were diagnosed through Ultrasonography, so 98.9% corresponded. This indicates that the operators' subjective ability has a great impact on diagnosis of lesion in Ultrasonography diagnosis of a fatty liver, and that in check up chest CT, under 40 HU in the measurement of Liver HU can be used for reference materials in diagnosis of a fatty liver

  11. Fatty liver diagnostic from medical examination to analyze the accuracy between the abdominal ultrasonography and liver hounsfield units

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Wang Kyun [Dept. of Radiology, Cheongju Medical Center, Cheongju (Korea, Republic of); Kim, Sang Hyun [Dept. of Radiological Science, Shinhan University, Uijeongbu (Korea, Republic of)

    2017-06-15

    In abdominal Ultrasonography, the fatty liver is diagnosed through hepatic parenchymal echo increased parenchymal density and unclear blood vessel boundary, and according to many studies, abdominal Ultrasonography has 60 ∼ 90% of sensitivity and 84 ∼ 95% of specificity in diagnosis of fatty liver, but the result of Ultrasonography is dependent on operators, so there can be difference among operators, and quantitative measurement of fatty infiltration is impossible. Among examinees who same day received abdominal Ultrasonography and chest computed tomography (CT), patients who were diagnosed with a fatty liver in the Ultrasonography were measured with liver Hounsfield Units (HU) of chest CT imaging to analyze the accuracy of the fatty liver diagnosis. Among 720 subject examinees, those who were diagnosed with a fatty liver through abdominal Ultrasonography by family physicians were 448, which is 62.2%. The result of Liver HU measurement in the chest CT imaging of those who were diagnosed with a fatty liver showed that 175 out of 720 had the measured value of less than 40 HU, which is 24.3%, and 173 were included to the 175 among 448 who were diagnosed through Ultrasonography, so 98.9% corresponded. This indicates that the operators' subjective ability has a great impact on diagnosis of lesion in Ultrasonography diagnosis of a fatty liver, and that in check up chest CT, under 40 HU in the measurement of Liver HU can be used for reference materials in diagnosis of a fatty liver.

  12. Adenopathies in lung cancer: a comparison of pathology, Computed Tomography and endoscopic ultrasound findings

    International Nuclear Information System (INIS)

    Potepan, P.; Meroni, E.; Spinelli, P.

    1999-01-01

    A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread [it

  13. Ultrasonography of the shoulder: pitfalls and variants

    International Nuclear Information System (INIS)

    Friedman, L.; Finlay, K.; Popowich, T.; Jurriaans, E.

    2002-01-01

    Ultrasonography (US) of the shoulder, particularly the evaluation of the rotator cuff, is the most common examination of the musculoskeletal system performed in most practices. Despite this, it remains one of the most difficult examinations to learn. There are many pitfalls and errors that can occur initially, but once mastered, US of the rotator cuff is one of the best methods available for diagnosing rotator cuff disease. The literature reports a 91%-95% sensitivity and close to 90% specificity and accuracy in the assessment of both partial and full thickness tears. This compares favourably with magnetic resonance imaging (MRI), where a more recent study reported an 84% sensitivity, 97% specificity and an accuracy of 93% for combined partial and full thickness tears of the rotator cuff. Advantages of US include low cost, easy access, high degree of accuracy in expert hands, ease of comparison with the opposite side, dynamic real-time examination, ability to focus on the exact site of the patient's pain and graded compression availability. It is for these reasons that we hope to outline the various pitfalls and common errors that can occur during the examination in a systematic fashion. It must also be pointed out that computed tomographic arthrography and magnetic resonance arthrography remain the investigations of choice for assessing labral disorders. (author)

  14. Spatially modulated magnetic structure of EuS due to the tetragonal domain structure of SrTiO3 APS

    CERN Document Server

    Rosenberg, Aaron J.; Kirtley, John R.; Gedik, Nuh; Moodera, Jagadeesh S.; Moler, Kathryn A.

    2017-12-15

    The combination of ferromagnets with topological superconductors or insulators allows for new phases of matter that support excitations such as chiral edge modes and Majorana fermions. EuS, a wide-bandgap ferromagnetic insulator with a Curie temperature around 16 K, and SrTiO3 (STO), an important substrate for engineering heterostructures, may support these phases. We present scanning superconducting quantum interference device measurements of EuS grown epitaxially on STO that reveal micron-scale variations in ferromagnetism and paramagnetism. These variations are oriented along the STO crystal axes and only change their configuration upon thermal cycling above the STO cubic-to-tetragonal structural transition temperature at 105 K, indicating that the observed magnetic features are due to coupling between EuS and the STO tetragonal structure. We speculate that the STO tetragonal distortions may strain the EuS, altering the magnetic anisotropy on a micron scale. This result demonstrates that local variation in...

  15. Metastatic tonsillar squamous cell carcinoma masquerading as a pancreatic cystic tumor and diagnosed by EUS-guided FNA.

    Science.gov (United States)

    Glass, Ryan; Andrawes, Sherif A; Hamele-Bena, Diane; Tong, Guo-Xia

    2017-11-01

    Metastatic carcinoma to the pancreas is uncommon and head and neck squamous carcinoma metastatic to the pancreas is extremely rare. Metastatic squamous cell carcinoma to the pancreas presents a unique diagnostic challenge: in addition to mimicking the rare primary squamous cell carcinoma of the pancreas based on cytologic, histologic, and immunohistochemical features, it may be mistaken for a cystic neoplasm of the pancreas because of its high predilection for cystic degeneration in metastatic sites. Herein, we report a case of tonsillar squamous cell carcinoma with a cystic pancreatic metastasis diagnosed by ultrasound-guided fine needle aspiration biopsy (EUS-FNA). This represents a third reported case of metastatic squamous cell carcinoma to the pancreas from the head and neck region. Metastatic squamous cell carcinoma should be considered in the differential diagnosis of EUS-FNA during evaluation of pancreatic cystic lesion. © 2017 Wiley Periodicals, Inc.

  16. Pretreatment Dysphagia in Esophageal Cancer Patients May Eliminate the Need for Staging by Endoscopic Ultrasonography.

    Science.gov (United States)

    Ripley, R Taylor; Sarkaria, Inderpal S; Grosser, Rachel; Sima, Camelia S; Bains, Manjit S; Jones, David R; Adusumilli, Prasad S; Huang, James; Finley, David J; Rusch, Valerie W; Rizk, Nabil P

    2016-01-01

    Neoadjuvant therapy is commonly administered to patients with localized disease who have T3-4 esophageal disease as staged by endoscopic ultrasound (EUS). Previously, we noted that patients who present with dysphagia have a higher EUS T stage. We hypothesized that the presence of dysphagia is predictive of EUS T3-4 disease and that staging EUS could be forgone for esophageal cancer patients with dysphagia. We performed a prospective, intent-to-treat, single-cohort study in which patients with potentially resectable esophageal cancer completed a standardized four-tier dysphagia score survey. EUS was performed as part of our standard evaluation. To determine whether the presence of dysphagia predicted EUS T3-4 disease, the dysphagia score was compared with EUS T stage. The study enrolled 114 consecutive patients between August 2012 and February 2014: 77% (88 of 114) received neoadjuvant therapy, 18% (20 of 114) did not, and 5% (6 of 114) pursued treatment elsewhere. In total, 70% (80 of 114) underwent esophagectomy; of these, 54% (61 of 114) had dysphagia and 46% (53 of 114) did not. Dysphagia scores were 66% (40 of 61) grade 1, 25% (15 of 61) grade 2, and 10% (6 of 61) grade 3 to 4. Among patients with dysphagia, 89% (54 of 61) had T3-4 disease by EUS; among those without dysphagia, only 53% (28 of 53) had T3-4 disease by EUS (p < 0.001). The presence of dysphagia in patients with esophageal cancer was highly predictive of T3-4 disease by EUS. On the basis of this finding, approximately 50% of patients currently undergoing staging EUS at our institution could potentially forgo EUS before neoadjuvant therapy. Patients without dysphagia, however, should still undergo EUS. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. USES 2.0, The Uniform System for the Evaluation of Substances, version 2.0 ; supplement to EUSES

    OpenAIRE

    Linders JBHJ; Jager DT (eds.); CSR; ECO

    1997-01-01

    This interim report describes the updated risk assessment system for agricultural and non-agricultural pesticides. It will be integrated with the European Union System for the Evaluation of Substances, EUSES 1.0, into USES 2.0, the second version of the Uniform System for the Evaluation of Substances. The report is primarily made as preparation to the programming and testing of USES 2.0.

  18. Value of Lung Ultrasonography in the Diagnosis and Outcome Prediction of Pediatric Community-Acquired Pneumonia with Necrotizing Change.

    Directory of Open Access Journals (Sweden)

    Shen-Hao Lai

    Full Text Available Lung ultrasonography has been advocated in diagnosing pediatric community-acquired pneumonia. However, its function in identifying necrotizing pneumonia, a complication, has not been explored. This study investigated the value of lung ultrasonography in diagnosing pediatric necrotizing pneumonia and its role in predicting clinical outcomes.We retrospectively reviewed 236 children with community-acquired pneumonia who were evaluated using lung ultrasonography within 2-3 days after admission. The ultrasonographic features assessed included lung perfusion, the presence of hypoechoic lesions, and the amount of pleural effusion. Chest computed tomography was also performed in 96 patients as clinically indicated. Detailed records of clinical information were obtained.Our results showed a high correlation between the degree of impaired perfusion in ultrasonography and the severity of necrosis in computed tomography (r = 0.704. The degree of impaired perfusion can favorably be used to predict massive necrosis in computed tomography (area under the receiver operating characteristic curve, 0.908. The characteristics of impaired perfusion and hypoechoic lesions in ultrasonography were associated with an increased risk of pneumatocele formation (odds ratio (OR, 10.11; 95% CI, 2.95-34.64 and the subsequent requirement for surgical lung resection (OR, 8.28; 95% CI, 1.86-36.93. Furthermore, a longer hospital stay would be expected if moderate-to-massive pleural effusion was observed in addition to impaired perfusion in ultrasonography (OR, 3.08; 95% CI, 1.15-8.29.Lung ultrasonography is favorably correlated with chest computed tomography in the diagnosis of necrotizing pneumonia, especially regarding massive necrosis of the lung. Because it is a simple and reliable imaging tool that is valuable in predicting clinical outcomes, we suggest that ultrasonography be applied as a surrogate for computed tomography for the early detection of severe necrotizing

  19. Contrast-enhanced ultrasonography depicts small tumor vessels for the evaluation of pancreatic tumors

    International Nuclear Information System (INIS)

    Okamoto, Yuko; Kawamoto, Hirofumi; Takaki, Akinobu; Ishida, Etsuji; Ogawa, Tsuneyoshi; Kuwaki, Kenji; Kobayashi, Yoshiyuki; Sakaguchi, Kohsaku; Shiratori, Yasushi

    2007-01-01

    Objective: The aim of this study is to evaluate the efficacy of contrast-enhanced ultrasonography for the diagnosis of pancreatic tumors. Materials and methods: Contrast-enhanced ultrasonography with Levovist was performed on 62 consecutive patients (53 with pancreatic cancer, 4 with islet cell tumor, 3 with inflammatory pancreatic tumor, and 2 with metastatic tumor). The vascular and perfusion image phases of the tumors were evaluated and compared with the findings of contrast-enhanced computed tomography. Results: Contrast-enhanced ultrasonography showed tumor vessels around and/or in the tumor at the vascular image phase in 79% of pancreatic cancer patients (42/53). At the perfusion image phase, 96% of pancreatic cancers (51/53) were classified as hypo-enhancement type. However, tiny spotty or irregular heterogeneous enhanced lesions were found in 84% of hypo-enhanced pancreatic cancer patients (43/51). The presence of small vessels at the vascular image phase was closely correlated with the presence of these intratumor regional enhanced lesions at the perfusion image phase (κ coefficient = 0.42). The sensitivity of contrast-enhanced ultrasonography (100%) for pancreatic cancer was superior to that of contrast-enhanced computed tomography (91%), but no significant difference was observed between the two (McNemar test: p = 0.063). Conclusion: Contrast-enhanced ultrasonography with Levovist successfully visualizes fine vessels and enhancement in pancreatic tumors, and is useful for evaluating pancreatic tumors

  20. Harmonic Contrast-Enhanced Endoscopic Ultrasonography for the Guidance of Fine-Needle Aspiration in Solid Pancreatic Masses

    DEFF Research Database (Denmark)

    Seicean, A; Badea, R; Moldovan-Pop, A

    2015-01-01

    Purpose: The global accuracy of fine-needle aspiration guided by endoscopic ultrasound (EUS-FNA) for pancreatic adenocarcinoma is about 85 %. The use of contrast agents during EUS to highlight vessels and the necrotic parts of pancreatic masses may improve biopsy guidance. Our aim was to assess...... whether the guidance of FNA by harmonic contrast-enhanced endoscopic ultrasound (CH-EUS) would increase diagnostic accuracy relative to conventional EUS-FNA in the same pancreatic masses. Patients and Methods: In a prospective study, EUS-FNA was performed in patients with pancreatic masses on CT scan......, followed by harmonic CH-EUS using SonoVue. A second cluster of CH-EUS-FNA was performed on contrast-enhanced images. The final diagnosis was based on the results of EUS-FNA and surgery, or the findings after 12 months' follow-up. Results: The final diagnosis was adenocarcinoma (n = 35), chronic...

  1. [Low grade renal trauma (Part II): diagnostic validity of ultrasonography].

    Science.gov (United States)

    Grill, R; Báca, V; Otcenásek, M; Zátura, F

    2010-04-01

    The aim of the study was to verify whether ultrasonography can be considered a reliable method for the diagnosis of low-grade renal trauma. The group investigated included patients with grade I or grade II blunt renal trauma, as classified by the AAST grading system, in whom ultrasonography alone or in conjunction with computed tomography was used as a primary diagnostic method. B-mode ultrasound with a transabdominal probe working at frequencies of 2.5 to 5.0 MHz was used. Every finding of post-traumatic changes in the renal tissues, i.e., post-contusion hypotonic infiltration of the renal parenchyma or subcapsular haematoma, was included. The results were statistically evaluated by the Chi-square test with the level of significance set at 5%, using Epi Info Version 6 CZ software. The group comprised 112 patients (43 women, 69 men) aged between 17 and 82 years (average, 38 years). It was possible to diagnose grade I or grade II renal injury by ultrasonography in only 60 (54%) of them. The statistical significance of ultrasonography as the only imaging method for the diagnosis of low-grade renal injury was not confirmed (p=0.543) Low-grade renal trauma is a problem from the diagnostic point of view. It usually does not require revision surgery and, if found during repeat surgery for more serious injury of another organ, it usually does not receive attention. Therefore, the macroscopic presentation of grade I and grade II renal injury is poorly understood, nor are their microscopic findings known, because during revision surgery these the traumatised kidneys are not usually removed and their injuries at autopsy on the patients who died of multiple trauma are not recorded either. The results of this study demonstrated that the validity of ultrasonography for the diagnosis of low-grade renal injury is not significant, because this examination can reveal only some of the renal injuries such as perirenal haematoma. An injury to the renal parenchyma is also indicated by

  2. Ultrasonography and surgery of canine biliary diseases.

    Science.gov (United States)

    Vörös, K; Németh, T; Vrabély, T; Manczur, F; Tóth, J; Magdus, M; Perge, E

    2001-01-01

    Findings of hepatic and gallbladder ultrasonography were analyzed in 12 dogs with gallbladder and/or extrahepatic biliary tract obstruction and compared with the results of exploratory laparotomy. Hepatic ultrasonography demonstrated normal liver in 2 dogs and hepatic abnormalities in 10 animals. The following ultrasonographic diagnoses were established compared to surgical findings: gallbladder obstruction caused by bile sludge (correct/incorrect: 1/2, surgical diagnosis: choleliths in one case), gallbladder obstruction caused by neoplasm (0/1, surgical diagnosis: mucocele), gallbladder and extrahepatic biliary tract obstruction due to choleliths (3/3), extrahepatic biliary tract obstruction caused by pancreatic mass (1/1) and small intestinal volvulus (1/1). Bile peritonitis caused by gallbladder rupture (4/4) was correctly diagnosed by ultrasound, aided with ultrasonographically-guided abdominocentesis and peritoneal fluid analysis. Rupture of the gallbladder should be suspected in the presence of a small, echogenic gallbladder or in the absence of the organ together with free abdominal fluid during ultrasonography. Laparotomy was correctly indicated by ultrasonography in all cases. However, the direct cause of obstruction could not be determined in 2 of the 12 dogs by ultrasonography alone.

  3. Role of Ultrasonography in Acute Abdomen

    International Nuclear Information System (INIS)

    An, Ji Hyun; Lee, Yeon Hee; Kim, Tae Hoon; Yu, Pil Mun; Choi, Young Hi; Kim, Sang Joon; Kim, Seung Cheul; Cho, Jeong Hee; Jung, Jae Un

    1996-01-01

    Authors analyzed the distribution of diseases and compared ultrasonographic conclusions with confirmed diagnoses of emergency abdominal ultrasonographies in acute abdominal conditions. We evaluated the role of emergency abdominal ultrasonography especially in the decision of emergency operation. In one hundred and forty five patients, emergent abdominal ultrasonography was performed within on admission. We compared the sonographic conclusion with postoperative pathology and analyzed the diagnoses of medically treated diseases. Twenty-eight patients under vent surgery and 117 patients were treated conservatively. Among the surgically treated patients, 19 patients (70.4%) were correctly diagnosed by preoperative ultrasonography.These included acute appendicitis (N = 8), acute cholecystitis (n = 7), ovarian cyst torsion (n = 2), and liver abscess (n = 1). Correct preoperative diagnosis was not made in 9 patients, including acute appendicitis (n = 4),peritonitis due to bowel perforation (n = 2), ectopic pregnancy (n = 1), colonic diverticulitis (n = 1 ) and pelvic inflammatory disease (n = 1 ). Clinical follow up was possible in 50 patients among the non-operative patient group, and the clinical diagnoses were chronic liver disease (n = 14), acute pyelonephritis (n = 10), and biliary stone (n = 10). Emergent ultrasonography plays an important role in acute abdominal conditions by supporting the differential diagnosis of medical and surgical disease

  4. Role of Ultrasonography in Acute Abdomen

    Energy Technology Data Exchange (ETDEWEB)

    An, Ji Hyun; Lee, Yeon Hee; Kim, Tae Hoon; Yu, Pil Mun; Choi, Young Hi; Kim, Sang Joon; Kim, Seung Cheul; Cho, Jeong Hee [Dankook University College of Medicine, Cheonan (Korea, Republic of); Jung, Jae Un [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1996-12-15

    Authors analyzed the distribution of diseases and compared ultrasonographic conclusions with confirmed diagnoses of emergency abdominal ultrasonographies in acute abdominal conditions. We evaluated the role of emergency abdominal ultrasonography especially in the decision of emergency operation. In one hundred and forty five patients, emergent abdominal ultrasonography was performed within on admission. We compared the sonographic conclusion with postoperative pathology and analyzed the diagnoses of medically treated diseases. Twenty-eight patients underwent surgery and 117 patients were treated conservatively. Among the surgically treated patients, 19 patients (70.4%) were correctly diagnosed by preoperative ultrasonography.These included acute appendicitis (N = 8), acute cholecystitis (n = 7), ovarian cyst torsion (n = 2), and liver abscess (n = 1). Correct preoperative diagnosis was not made in 9 patients, including acute appendicitis (n = 4), peritonitis due to bowel perforation (n = 2), ectopic pregnancy (n = 1), colonic diverticulitis (n = 1) and pelvic inflammatory disease (n = 1). Clinical follow up was possible in 50 patients among the non-operative patient group, and the clinical diagnoses were chronic liver disease (n = 14), acute pyelonephritis (n = 10), and biliary stone (n = 10). Emergent ultrasonography plays an important role in acute abdominal conditions by supporting the differential diagnosis of medical and surgical disease

  5. Fluorescence cytology with 5-aminolevulinic acid in EUS-guided FNA as a method for differentiating between malignant and benign lesions (with video).

    Science.gov (United States)

    Ikeura, Tsukasa; Takaoka, Makoto; Uchida, Kazushige; Shimatani, Masaaki; Miyoshi, Hideaki; Kato, Kota; Ohe, Chisato; Uemura, Yoshiko; Kaibori, Masaki; Kwon, A-Hon; Okazaki, Kazuichi

    2015-01-01

    EUS-guided FNA (EUS-FNA) has been increasingly performed to obtain specimens for the pathological evaluation of patients with GI and pancreaticobiliary masses as well as lymphadenopathies of unknown origin. Photodynamic diagnosis by using 5-aminolebulinic acid (ALA) has been reported to be useful for enabling the visual differentiation between malignant and normal tissue in various cancers. To evaluate the diagnostic accuracy of fluorescence cytology with ALA in EUS-FNA. A prospective study. A single center. A total of 28 consecutive patients who underwent EUS-FNA for the pathological diagnosis of a pancreaticobiliary mass lesion or intra-abdominal lymphadenopathy of unknown origin. Patients were orally administered ALA 3 to 6 hours before EUS-FNA. The sample was obtained via EUS-FNA for fluorescence cytology and conventional cytology. A single gastroenterologist performed the fluorescence cytology by using fluorescence microscopy after the procedure, independently of the conventional cytology by pathologists. The accuracy of fluorescence cytology with ALA in the differentiation between benign and malignant lesions by comparing the results of fluorescence cytology with the final diagnosis. Of the 28 patients included in the study, 22 were considered as having malignant lesions and 6 patients as having benign lesions. Fluorescence cytology could correctly discriminate between benign and malignant lesions in all patients. Therefore, both the sensitivity and specificity of fluorescence cytology were 100% in our study. Fluorescence cytology was performed by only 1 gastroenterologist with a small number of patients. Fluorescence cytology with ALA in EUS-FNA may be an effective and simple method for differentiating between benign and malignant lesions. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  6. Ultrasonography of the scrotum in adults

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Anna L.; Scotegagna, Eduardo; Nowitaki, Kristina M.; Kim, Young M. [Dept. of UMass Memorial Medical Center, University of Massachusetts Medical Center, Worcester (United States)

    2016-07-15

    Ultrasonography is the ideal noninvasive imaging modality for evaluation of scrotal abnormalities. It is capable of differentiating the most important etiologies of acute scrotal pain and swelling, including epididymitis and testicular torsion, and is the imaging modality of choice in acute scrotal trauma. In patients presenting with palpable abnormality or scrotal swelling, ultrasonography can detect, locate, and characterize both intratesticular and extratesticular masses and other abnormalities. A 12-17 MHz high frequency linear array transducer provides excellent anatomic detail of the testicles and surrounding structures. In addition, vascular perfusion can be easily assessed using color and spectral Doppler analysis. In most cases of scrotal disease, the combination of clinical history, physical examination, and information obtained with ultrasonography is sufficient for diagnostic decision-making. This review covers the normal scrotal anatomy as well as various testicular and scrotal lesions.

  7. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    International Nuclear Information System (INIS)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung

    1996-01-01

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  8. Scintigraphy and ultrasonography of various thyroid diseases

    International Nuclear Information System (INIS)

    Ban, Yoshio; Nagakura, Hozumi; Kawauchi, Akihiro; Fukunari, Nobuhiro; Itoh, Kunihiko; Higashi, Tomomitsu.

    1987-01-01

    We reported the usefulness of scintigraphy and ultrasonography of various thyroid diseases. The scintigraphy were useful information in the determination of functioning adenoma, location of ectopic thyroid glands and appearance of lang and bone metastasis of thyroid carcinoma. As ultrasonography were able to be observation of internal structure of thyroid gland, that maight be used to determined associated nodular lesions in diffuse goiter and differentiation between benign and malignant tumor in nodular goiter. In observation of calcifications of goiter, soft X rays apparatus were usefull tool. US, as initial diagnostic test before scintiscanning, provided useful information and minimized radiation exposure. (author)

  9. An experimental comparative study of radiography, ultrasonography and CT imaging in the IV catheter fragment

    International Nuclear Information System (INIS)

    Kweon, Dae Cheol

    2016-01-01

    The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon® IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose (0.2139 mSv·Gy-1·cm-2) form DAP DAP (0.93 μGy·m2 ), and dose length product (DLP) (201 mGy·cm) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography

  10. Transabdominal Ultrasonography of the Small Bowel

    Directory of Open Access Journals (Sweden)

    Rudolf Kralik

    2013-01-01

    Full Text Available In the era of double balloon enteroscopy, capsule endoscopy, CT, and MRI enterography is transabdominal ultrasonography (TUS underestimated method for evaluation of small bowel pathology. As often initial imagine method in abdominal complaints, nowadays has TUS much better diagnostic potential than two decades ago. High-resolution ultrasound probes with harmonic imaging significantly improve resolution of bowel wall in real time, with possibility to asses bowel peristalsis. Color flow doppler enables evaluation of intramural bowel vascularisation, pulse wave doppler helps to quantificate flow in coeliac and superior mesenteric arteries. Small intestine contrast ultrasonography with oral contrast fluid, as well as contrast enhanced ultrasonography with intravenous microbubble contrast also improves small bowel imaging. We present a review of small intestine pathology that should be detected during ultrasound examinations, discuss technical requirements, advantages and limitations of TUS, typical ultrasound signs of Crohn's disease, ileus, celiac disease, intussusception, infectious enteritis, tumours, ischemic and haemorrhagic conditions of small bowel. In the hands of experienced investigator, despite some significant limitations(obesity, meteorism, is transabdominal ultrasonography reliable, noninvasive and inexpensive alternative method to computerised tomography (CT and magnetic resonance imaging (MRI in small bowel examination.

  11. Emergency surgeon-performed hepatobiliary ultrasonography.

    LENUS (Irish Health Repository)

    Kell, M R

    2012-02-03

    BACKGROUND: Acute hepatobiliary pathology is a common general surgical emergency referral. Diagnosis requires imaging of the biliary tree by ultrasonography. The accuracy and impact of surgeon-performed ultrasonography (SUS) on the diagnosis of emergent hepatobiliary pathology was examined. METHODS: A prospective study, over a 6-month period, enrolled all patients with symptoms or signs of acute hepatobiliary pathology. Patients provided informed consent and underwent both SUS and standard radiology-performed ultrasonography (RUS). SUS was performed using a 2-5-MHz broadband portable ultrasound probe by two surgeons trained in ultrasonography, and RUS using a 2-5-MHz fixed unit. SUS results were correlated with those of RUS and pathological diagnoses. RESULTS: Fifty-three consecutive patients underwent 106 ultrasonographic investigations. SUS agreed with RUS in 50 (94.3 per cent) of 53 patients. SUS accurately detected cholelithiasis in all but two cases and no patient was inaccurately diagnosed as having cholelithiasis at SUS (95.2 per cent sensitivity and 100 per cent specificity). As an overall complementary diagnostic tool SUS provided the correct diagnosis in 96.2 per cent of patients. Time to scan was significantly shorter following SUS (3.1 versus 12.0 h, P < 0.05). CONCLUSION: SUS provides a rapid and accurate diagnosis of emergency hepatobiliary pathology and may contribute to the emergency management of hepatobiliary disease.

  12. Quantitative muscle ultrasonography in amyotrophic lateral sclerosis.

    NARCIS (Netherlands)

    Arts, I.M.P.; Rooij, F.G. van; Overeem, S.; Pillen, S.; Janssen, H.M.; Schelhaas, H.J.; Zwarts, M.J.

    2008-01-01

    In this study, we examined whether quantitative muscle ultrasonography can detect structural muscle changes in early-stage amyotrophic lateral sclerosis (ALS). Bilateral transverse scans were made of five muscles or muscle groups (sternocleidomastoid, biceps brachii/brachialis, forearm flexor group,

  13. Diagnostic accuracy of oblique chest radiograph for occult pneumothorax: comparison with ultrasonography

    OpenAIRE

    Matsumoto, Shokei; Sekine, Kazuhiko; Funabiki, Tomohiro; Orita, Tomohiko; Shimizu, Masayuki; Hayashida, Kei; Kazamaki, Taku; Suzuki, Tatsuya; Kishikawa, Masanobu; Yamazaki, Motoyasu; Kitano, Mitsuhide

    2016-01-01

    Backgraound An occult pneumothorax is a pneumothorax that is not seen on a supine chest X-ray but is detected by computed tomography scanning. However, critical patients are difficult to transport to the computed tomography suite. We previously reported a method to detect occult pneumothorax using oblique chest radiography (OXR). Several authors have also reported that ultrasonography is an effective technique for detecting occult pneumothorax. The aim of this study was to evaluate the useful...

  14. Isolated and unexplained dilation of the common bile duct on computed tomography scanscans

    Directory of Open Access Journals (Sweden)

    Naveen B. Krishna

    2012-07-01

    Full Text Available Isolated dilation of common bile duct (CBD with normal sized pancreatic duct and without identifiable stones or mass lesion (unexplained is frequently encountered by computed tomography/magnetic resonance imaging. We studied the final diagnoses in these patients and tried to elucidate factors that can predict a malignant etiology. This is a retrospective analysis of prospective database from a University based clinical practice (2002- 2008. We included 107 consecutive patients who underwent endoscopic ultrasound (EUS for evaluation of isolated and unexplained CBD dilation noted on contrast computed tomography scans. EUS examination was performed using a radial echoendoscope followed by a linear echoechoendoscope, if a focal mass lesion was identified. Fine-needle aspirates were assessed immediately by an attending cytopathologist. Main outcome measurements included i prevalence of neoplasms, CBD stones and chronic pancreatitis and ii performance characteristics of EUS/EUS-fine needle aspiration (EUS-FNA. A malignant neoplasm was found in 16 patients (14.9% of the study subjects, all with obstructive jaundice (ObJ. Six patients had CBD stones; three with ObJ and three with abnormal liver function tests. EUS findings suggestive of chronic pancreatitis were identified in 27 patients. EUSFNA had 97.3% accuracy (94.1% in subset with ObJ with a sensitivity of 81.2% and specificity of 100% for diagnosing malignancy. Presence of ObJ and older patient age were only significant predictors of malignancy in our cohort. Amongst patients with isolated and unexplained dilation of CBD, the risk of malignancy is significantly higher in older patients presenting with ObJ. EUS-FNA can diagnose malignancy in these patients with high accuracy besides identifying other potential etiologies including missed CBD stones and chronic pancreatitis.

  15. Economic analysis of bedside ultrasonography (US) implementation in an Internal Medicine department.

    Science.gov (United States)

    Testa, Americo; Francesconi, Andrea; Giannuzzi, Rosangela; Berardi, Silvia; Sbraccia, Paolo

    2015-12-01

    The economic crisis, the growing healthcare demand, and Defensive Medicine wastefulness, strongly recommend the restructuring of the entire medical network. New health technology, such as bedside ultrasonography, might successfully integrate the clinical approach optimizing the use of limited resources, especially in a person-oriented vision of medicine. Bedside ultrasonography is a safe and reliable technique, with worldwide expanding employment in various clinical settings, being considered as "the stethoscope of the 21st century". However, at present, bedside ultrasonography lacks economic analysis. We performed a Cost-Benefit Analysis "ex ante", with a break-even point computing, of bedside ultrasonography implementation in an Internal Medicine department in the mid-term. Number and kind estimation of bedside ultrasonographic studies were obtained by a retrospective study, whose data results were applied to the next 3-year period (foresight study). All 1980 foreseen bedside examinations, with prevailing multiorgan ultrasonographic studies, were considered to calculate direct and indirect costs, while specific and generic revenues were considered only after the first semester. Physician professional training, equipment purchase and working time represented the main fixed and variable cost items. DRG increase/appropriateness, hospitalization stay shortening and reduction of traditional ultrasonography examination requests mainly impacted on calculated revenues. The break-even point, i.e. the volume of activity at which revenues exactly equal total incurred costs, was calculated to be 734 US examinations, corresponding to € 81,998 and the time considered necessary to reach it resulting 406 days. Our economic analysis clearly shows that bedside ultrasonography implementation in clinical daily management of an Internal Medicine department can produce consistent savings, or economic profit according to managerial choices (i.e., considering public or private targets

  16. Technical aspects of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline - March 2017.

    Science.gov (United States)

    Polkowski, Marcin; Jenssen, Christian; Kaye, Philip; Carrara, Silvia; Deprez, Pierre; Gines, Angels; Fernández-Esparrach, Gloria; Eisendrath, Pierre; Aithal, Guruprasad P; Arcidiacono, Paolo; Barthet, Marc; Bastos, Pedro; Fornelli, Adele; Napoleon, Bertrand; Iglesias-Garcia, Julio; Seicean, Andrada; Larghi, Alberto; Hassan, Cesare; van Hooft, Jeanin E; Dumonceau, Jean-Marc

    2017-10-01

    For routine EUS-guided sampling of solid masses and lymph nodes (LNs) ESGE recommends 25G or 22G needles (high quality evidence, strong recommendation); fine needle aspiration (FNA) and fine needle biopsy (FNB) needles are equally recommended (high quality evidence, strong recommendation).When the primary aim of sampling is to obtain a core tissue specimen, ESGE suggests using 19G FNA or FNB needles or 22G FNB needles (low quality evidence, weak recommendation).ESGE recommends using 10-mL syringe suction for EUS-guided sampling of solid masses and LNs with 25G or 22G FNA needles (high quality evidence, strong recommendation) and other types of needles (low quality evidence, weak recommendation). ESGE suggests neutralizing residual negative pressure in the needle before withdrawing the needle from the target lesion (moderate quality evidence, weak recommendation).ESGE does not recommend for or against using the needle stylet for EUS-guided sampling of solid masses and LNs with FNA needles (high quality evidence, strong recommendation) and suggests using the needle stylet for EUS-guided sampling with FNB needles (low quality evidence, weak recommendation).ESGE suggests fanning the needle throughout the lesion when sampling solid masses and LNs (moderate quality evidence, weak recommendation).ESGE equally recommends EUS-guided sampling with or without on-site cytologic evaluation (moderate quality evidence, strong recommendation). When on-site cytologic evaluation is unavailable, ESGE suggests performance of three to four needle passes with an FNA needle or two to three passes with an FNB needle (low quality evidence, weak recommendation).For diagnostic sampling of pancreatic cystic lesions without a solid component, ESGE suggests emptying the cyst with a single pass of a 22G or 19G needle (low quality evidence, weak recommendation). For pancreatic cystic lesions with a solid component, ESGE suggests sampling of the solid component using the same technique as in the

  17. Ultrasonography in Early Diagnosis of Heterotopic Ossification

    Directory of Open Access Journals (Sweden)

    Shan-Hui Lin

    2014-12-01

    Full Text Available We report here the case of a 32-year-old man with a history of traumatic brain injury who presented with swelling of his right thigh. Soft tissue ultrasonography performed 3 days after the onset of symptoms showed a heterogeneous hyperechoic lesion with the formation of cysts and hypervascularity in the right iliopsoas abutting the surface of the femoral bone. This became a diffuse echogenic plaque with a posterior acoustic shadowing 12 days later. A diagnosis of heterotopic ossification was made on the basis of the presence of typical ultrasonographic findings and was confirmed by pathology. We emphasize that an early diagnosis of heterotopic ossification can be made with ultrasonography and can lead to early treatment.

  18. Vascular access: the impact of ultrasonography

    Science.gov (United States)

    de Almeida, Carlos Eduardo Saldanha

    2016-01-01

    ABSTRACT Vascular punctures are often necessary in critically ill patients. They are secure, but not free of complications. Ultrasonography enhances safety of the procedure by decreasing puncture attempts, complications and costs. This study reviews important publications and the puncture technique using ultrasound, bringing part of the experience of the intensive care unit of the Hospital Israelita Albert Einstein, São Paulo (SP), Brazil, and discussing issues that should be considered in future studies. PMID:28076607

  19. Differential diagnosis of calf pain by ultrasonography

    Directory of Open Access Journals (Sweden)

    Luciano Augusto Botter

    2008-03-01

    Full Text Available This paper aims to evaluate the recent and numerous applications of ultrasonography in the differential diagnosis of conditions that affect the popliteal fossa and lower limbs, resulting in calf pain. Popliteal cysts and their ruptures, aneurysms, hematomas, cellulitis, abscesses, soft tissue tumors and other fluid collections are easily identified by this technique. Moreover, post-trauma and inflammatory conditions affecting muscles and tendons, muscle necrosis, deep venous thrombosis and superficial thrombophlebitis are very well demonstrated by the ultrasonographic screening.

  20. Real time ultrasonography in obstructive jaundice

    International Nuclear Information System (INIS)

    Cho, Kyung Sik; Kim, Ho Kyun; Sung, Nak Kwan; Kim, Soon Yong

    1982-01-01

    Ultrasonography is a predominantly accurate, relatively simple unique diagnostic method of obstructive jaundice. The ultrasonographic findings of obstructive jaundice are dilated intra- and extrahepatic duct with intraluminal hyper reflective echo or mass in and/ or around the bile duct. The superiority of high resolution real time ultrasonography for the diagnosis of obstructive jaundice is bases on the easy detectability of extra- and intrahepatic bile ducts by its multiple sectional images in a short time, the flexibility of probe and small crystal size. Author evaluated real time sonographic findings 46 obstructive jaundice patients confirmed by surgery or radiographical examinations. The results were: 1. Diameter of extrahepatic duct in obstructive jaundice were varied from normal to 4.0 Cm, mostly 8 to 10 mm in diameter (26%). Degree of dilatation of biliary duct appeared more prominent in cancer patients than other causes of obstruction. 2. The site of obstruction was detected in 85% (39/46) and its common site was common bile duct in 63% (29/46). 3. The diagnostic accuracy of choledocholithiasis and cancer was 82% (22/27) and 44% (4/9), respectively. Diagnostic accuracy of the real time ultrasonography in obstructive jaundice was over all 75% (34/46)

  1. Contrast-Enhanced Ultrasonography in Crohn's Disease Diagnostics.

    Science.gov (United States)

    Białecki, Marcin; Białecka, Agnieszka; Laskowska, Katarzyna; Liebert, Ariel; Kłopocka, Maria; Serafin, Zbigniew

    2015-06-01

    The chronic nature of Crohn's disease (CD) implicates necessity of multiple control assessments throughout patient's life. It is accepted that in patients with CD requiring disease monitoring, magnetic resonance enterography (MRE) and computed tomography enterography (CTE) are--apart from endoscopy--imaging studies of first choice. In practice, diagnostic imaging of patients with CD is troublesome, since MRE is an expensive and complicated study, and CTE exposes patients to high doses of ionizing radiation. Therefore, there is a need for new, both non-invasive and effective, methods of imaging in CD. Contrast-Enhanced Ultrasonography (CEUS) is a relatively new method using gas-filled microbubbles serving as contrast agent. It allows for detailed assessment of blood perfusion within intestine wall and peri-intestinal tissues, which enables detection and monitoring of inflammation and its qualitative assessment. The purpose of this paper is to describe CEUS examination technique and its clinical applications in patients with Crohn's disease.

  2. Lenticulostriate vasculopathy of brain ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Soo Mee; Lee, Min Hee; Kim, Ha Na; Baek, Seung Yon; Lee, Sun Wha [Ewha Woman' s Univ. Mokdong Hospital, Seoul (Korea, Republic of)

    1997-05-01

    To describe the associated conditions and clinical significance of lenticulostriate uasculopathy (LSV) as demonstrated by cranial sonography. We retrospectively studied 77 LSV cases who between January 1994 and January 1996 had undergone cranial sonography for neonatal asphyxia, seizure, or bulging of anterior fontanel. Cranial sonography was performed with 7MHz real-time linear and sector transducers using an Acuson computed sonography unit;examinations were performed in sagittal and coronal planes. Twenty-six LSV patients underwent color Doppler studies, and in 24 of these, color signal and arterial pulse spectral wave were detected. LSV was grouped as one of three types, according to echogenicity:type I (less echogenic than sylvian fissure), type II (similar to sylvian fissure), and type III (more echogenic than sylvian fissures). We retrospectively evaluated associated sonographic abnormalities of the brain, and reviewed medical records for associated conditions and neurologic sequelae. Follow-up sonographic examinations were performed in 23 patients. There were 56 type I cases (73%), 17 of type II (22%) and 4 of type III (5%). Cranial sonographic results were normal in 36 cases (47%) and abnormal in 41(53%). Forty-eight cases of nonspecific causes and 29 cases of perinatal and acquired causes accounted for associated conditions. The echogenicity of LSV had not changed in 21 of 23 follow-up cases. Neurologic examinations were performed in 18 cases and in 14 of these (78%) there was no neurologic sequela. LSV in basal ganglia may be associated with nonspecific neonatal conditions, in addition to well known perinatal causes.

  3. Endoscopy/EUS-guided fiducial marker placement in patients with esophageal cancer: a comparative analysis of 3 types of markers.

    Science.gov (United States)

    Machiels, Melanie; van Hooft, Jeanin; Jin, Peng; van Berge Henegouwen, Mark I; van Laarhoven, Hanneke M; Alderliesten, Tanja; Hulshof, Maarten C

    2015-10-01

    Markers placed at the borders of esophageal tumors are potentially useful to facilitate radiotherapy (RT) target delineation, which offers the possibility of image-guided RT. To evaluate and compare the feasibility and technical benefit of endoscopy/EUS-guided marker placement of 3 different types of markers in patients with esophageal cancer referred for RT. Prospective, single-center, feasibility and comparative study. Tertiary-care medical center. Thirty patients with esophageal cancer who were referred for RT. Patients underwent endoscopy/EUS-guided implantation of 1 type of marker. A solid gold marker (SM) with fixed dimensions, a flexible coil-shaped gold marker (FM) with hand-cut length (2-10 mm), and a radiopaque hydrogel marker (HG) were used. Technical feasibility and adverse events were registered. CT scans and cone-beam CT scans (CBCT) acquired during RT were analyzed to determine and compare the visibility and continuous clear visibility of the implanted markers. Technical feasibility, technical benefit, and adverse events of 3 types of markers. A total of 101 markers were placed in 30 patients. Implantation was technically feasible in all patients without grade 3 to 4 adverse events. Two patients with asymptomatic mediastinitis and one with asymptomatic pneumothorax were seen. Visibility on CT scan of all 3 types of implanted markers was adequate for target delineation. Eighty percent of FMs remained continuously visible over the treatment period on CBCT, significantly better than SMs (63%) and HGs (11%) (P = .015). When we selected FMs ≥5 mm, 90.5% remained visible on CBCT between implantation and the end of RT. Single-center, nonrandomized design. Endoscopy/EUS-guided fiducial marker placement for esophageal cancer is both safe and feasible and can be used for target volume delineation purposes on CT. Our results imply a significant advantage of FMs over SMs and HGs, regarding visibility and continuous clear visibility over the treatment period

  4. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline - Updated January 2017.

    Science.gov (United States)

    Dumonceau, Jean-Marc; Deprez, Pierre H; Jenssen, Christian; Iglesias-Garcia, Julio; Larghi, Alberto; Vanbiervliet, Geoffroy; Aithal, Guruprasad P; Arcidiacono, Paolo G; Bastos, Pedro; Carrara, Silvia; Czakó, László; Fernández-Esparrach, Gloria; Fockens, Paul; Ginès, Àngels; Havre, Roald F; Hassan, Cesare; Vilmann, Peter; van Hooft, Jeanin E; Polkowski, Marcin

    2017-07-01

    For pancreatic solid lesions, ESGE recommends performing endoscopic ultrasound (EUS)-guided sampling as first-line procedure when a pathological diagnosis is required. Alternatively, percutaneous sampling may be considered in metastatic disease.Strong recommendation, moderate quality evidence.In the case of negative or inconclusive results and a high degree of suspicion of malignant disease, ESGE suggests re-evaluating the pathology slides, repeating EUS-guided sampling, or surgery.Weak recommendation, low quality evidence.In patients with chronic pancreatitis associated with a pancreatic mass, EUS-guided sampling results that do not confirm cancer should be interpreted with caution.Strong recommendation, low quality evidence.For pancreatic cystic lesions (PCLs), ESGE recommends EUS-guided sampling for biochemical analyses plus cytopathological examination if a precise diagnosis may change patient management, except for lesions ≤ 10 mm in diameter with no high risk stigmata. If the volume of PCL aspirate is small, it is recommended that carcinoembryonic antigen (CEA) level determination be done as the first analysis.Strong recommendation, low quality evidence.For esophageal cancer, ESGE suggests performing EUS-guided sampling for the assessment of regional lymph nodes (LNs) in T1 (and, depending on local treatment policy, T2) adenocarcinoma and of lesions suspicious for metastasis such as distant LNs, left liver lobe lesions, and suspected peritoneal carcinomatosis.Weak recommendation, low quality evidence.For lymphadenopathy of unknown origin, ESGE recommends performing EUS-guided (or alternatively endobronchial ultrasound [EBUS]-guided) sampling if the pathological result is likely to affect patient management and no superficial lymphadenopathy is easily accessible.Strong recommendation, moderate quality evidence.In the case of solid liver masses suspicious for metastasis, ESGE suggests performing EUS-guided sampling if the pathological result is likely

  5. The Place of Ultrasonography in the Evaluation of Rib Fractures

    OpenAIRE

    Fulya Bakılan; Gökhan Yüce; Ahmet Çağdaş Biçen; Tanju Keten

    2015-01-01

    Objective: The aim of this study was to investigate whether ultrasonography is superior to chest x-ray in detecting rib fractures in patients with minor blunt chest trauma and chest pain. Materials and Methods: Ultrasonography findings of 32 patients with minor blunt chest trauma showing no evidence of a rib fracture on anteroposterior chest x-rays, were documented. Presence of cortical discontinuities, acoustic shadows, reverberation artifacts, and hematoma by ultrasonography was...

  6. Correlation Theory Applied to the Static and Dynamic Properties of EuO and EuS

    DEFF Research Database (Denmark)

    Lindgård, Per-Anker

    1982-01-01

    was used previously in the correlation theory2) primarily to calculate static properties. Self‐consistent dynamic and static calculations have here been performed for EuO, which is an ideal Heisenberg magnet with significant second‐nearest‐neighbor interaction (J2 = J1/5). The two‐pole approximation...... a cutoff of the spectrum at high frequencies, which cannot be seen experimentally, but which significantly influences the frequency moments. It was found that the finite J2 has significant importance for a comparison between theory and experiment. It is concluded that the calculation for a simple cubic n.......n. magnet by Hubbard3) does not describe the EuO data accurately, neither with respect to line shape nor frequency scale. Significant differences are to be expected between EuO and EuS having opposite sign for J2....

  7. Is CEUS (contrast enhanced ultrasonography a useful tool in a beginner’s hands? How much can CAD (computer assisted diagnosis prototype help us in the characterization of malignancy in focal lesions of the liver?

    Directory of Open Access Journals (Sweden)

    Tudor Voicu Moga1,

    2016-12-01

    Full Text Available OBJECTIVES CEUS improved the characterization of focal lesions of the liver (FLLs, but it remains an operator-dependent method. The goal of this scientific paper was to test a computer assisted diagnosis (CAD prototype. MATERIALS AND METHODS 97 CEUS videos [34% hepatocellular carcinomas (HCC, 12.3% hypervascular metastases (HiperM, 11.3% hypovascular metastases (HipoM, 24.7% hemangiomas (HMG, 17.5% focal nodular hyperplasia (FNH] were used to develop a CAD prototype based on an algorithm that tested a binary decision classifier. Two young MDs, two experts and the CAD prototype, reevaluated 50 CEUS videos (diagnosis of benign vs. malignant lesions, in order to evaluate the beginner vs. expert diagnostic gap, the first being blinded by clinical data. RESULTS I-Beginner misdiagnosed 4/10-FNH, 3/10-HCC, 2/10-HMG, 1/10-HiperM, 1/10-HipoM. After being informed about the clinical data 2/10-FNH, 1/10-HCC. II-beginner misdiagnosed: 3/10-FNH; 3/10-HCC, 2/10- HMG, 1/10-HiperM. Unblinded: 1/10-HCC, 1/10- HMG. I-Expert: only 1/10-FNH, 1/10-HCC, 1/10- HMG misdiagnosed. Unblinded: all lesions were correctly diagnosed. II-Expert: 1/10-FNH, 1/10-HCC misdiagnosed. Unblinded: only 1/10-FNH was misdiagnosed. The CAD classifier managed a 75.2% overall correct classification rate. The overall classification before and after the uncovering of clinical data was: I beginner 78 %; 94%, II 82%; 96%. I expert 94%; 100%. II 96%; 98%. CONCLUSIONS The CAD prototype can assist a beginner for a better CEUS diagnostic accuracy. The integration of clinical data in the CAD algorithm is essential. Graphical abstract: Average Intensity variation in Arterial and Late Phase with supra unitary (meaning wash in and sub unitary pattern (meaning washout. REFERENCES 1.Sugimoto K, Shiraishi J, Moriyasu F, Doi K. Computer-aided diagnosis for contrast-enhanced ultrasound in the liver. World J Gastroenterol. 2010;2:215-223. 2. Gatos I, Tsantis S, Spiliopoulos S, Skouroliakou A, Theotokas I

  8. Microlithiasis of the gallbladder: role of endoscopic ultrasonography in patients with idiopathic acute pancreatitis Microcolecistolitíase: papel da ecoendoscopia em pacientes com pancreatite aguda sem causa aparente

    Directory of Open Access Journals (Sweden)

    José Celso Ardengh

    2010-01-01

    Full Text Available OBJECTIVES: Causes may be found in most cases of acute pancreatitis, however no etiology is found by clinical, biological and imaging investigations in 30% of these cases. Our objective was to evaluate results from endoscopic ultrasonography (EUS for diagnosis of gallbladder microlithiasis in patients with unexplained (idiopathic acute pancreatitis. METHODS: Thirty-six consecutive non-alcoholic patients with diagnoses of acute pancreatitis were studied over a five-year period. None of them showed signs of gallstones on transabdominal ultrasound or tomography. We performed EUS within one week of diagnosing acute pancreatitis. Diagnosis of gallbladder microlithiasis on EUS was based upon findings of hyperechoic signals of 0.5-3.0 mm, with or without acoustic shadowing. All patients (36 cases underwent cholecystectomy, in accordance with indication from the attending physician or based upon EUS diagnosis. RESULTS: Twenty-seven patients (75% had microlithiasis confirmed by histology and nine did not (25%. EUS findings were positive in twenty-five. Two patients had acute cholecystitis diagnosed at EUS that was confirmed by surgical and histological findings. In two patients, EUS showed cholesterolosis and pathological analysis disclosed stones not detected by EUS. EUS diagnosed microlithiasis in four cases not confirmed by surgical treatment. In our study, sensitivity, specificity and positive and negative predictive values to identify gallbladder microlithiasis (with 95% confidence interval were 92.6% (74.2-98.7%, 55.6% (22.7-84.7%, 86.2% (67.4-95.5% and 71.4% (30.3-94.9%, respectively. Overall EUS accuracy was 83.2%. CONCLUSIONS: EUS is a very reliable procedure to diagnose gallbladder microlithiasis and should be used for the management of patients with unexplained acute pancreatitis. This procedure should be part of advanced endoscopic evaluation.OBJETIVOS: Cerca de 30% dos doentes com PA rotulada como sem causa aparente apresentam

  9. APPLICATION OF LAPAROSCOPIC ULTRASONOGRAPHY IN ADNEXAL OPERATIONS

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Objective:To explore the clinical value on application of laparoscopic ultrasonography (Lap US) in the adnexal operation. Methods:Eleven patients including 7 cases of tubal pregnancy, 3 cases of teratoma of ovary and 1 case of endometrial cyst of ovary were examined by LapUS, then operated with laparoscopy.Results:The results showed that the modality presented is a big progress over the traditional operative management for adnexal diseas. Conclusions:It is a good approach for micro-surgery in the adnexal operation by laparoscopy.

  10. Optically neuronavigated ultrasonography in an intraoperative magnetic resonance imaging environment.

    Science.gov (United States)

    Katisko, Jani P A; Koivukangas, John P

    2007-04-01

    To develop a clinically useful method that shows the corresponding planes of intraoperative two-dimensional ultrasonography and intraoperative magnetic resonance imaging (MRI) scans determined with an optical neuronavigator from an intraoperative three-dimensional MRI scan data set, and to determine the qualitative and the quantitative spatial correspondence between the ultrasonography and MRI scans. An ultrasound probe was interlinked with an ergonomic and MRI scan-compatible ultrasonography probe tracker to the optical neuronavigator used in a low-field intraoperative MRI scan environment for brain surgery. Spatial correspondence measurements were performed using a custom-made ultrasonography/MRI scan phantom. In this work, instruments to combine intraoperatively collected ultrasonography and MRI scan data with an optical localization method in a magnetic environment were developed. The ultrasonography transducer tracker played an important role. Furthermore, a phantom for ultrasonography and MRI scanning was produced. This is the first report, to our knowledge, regarding the possibility of combining the two most important intraoperative imaging modalities used in neurosurgery, ultrasonography and MRI scanning, to guide brain tumor surgery. The method was feasible and, as shown in an illustrative surgical case, has direct clinical impact on image-guided brain surgery. The spatial deviation between the ultrasonography and the MRI scans was, on average, 1.90 +/- 1.30 mm at depths of 0 to 120 mm from the ultrasonography probe. The overall result of this work is a unique method to guide the neurosurgical operation with neuronavigated ultrasonography imaging in an intraoperative MRI scanning environment. The relevance of the method is emphasized in minimally invasive neurosurgery.

  11. Incidentally diagnosed Takayasu arteritis on thyroid ultrasonography showing prominent collateral vessels of thyroidal arteries and common carotid artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Se Jin; Kim, Eun Kyung [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    We report a case of middle-aged woman incidentally diagnosed with Takayasu arteritis during the ultrasonography of a thyroid gland nodule. Prominent collaterals of the thyroidal arteries and a thin common carotid artery with mural thickening and deficient intraluminal flow signals were initially depicted on the ultrasonography with color Doppler. Subsequent magnetic resonance angiography and computed tomography aortography confirmed the diagnosis with the imaging features of a bilateral long segment common carotid artery occlusion and segmental stenosis of the left subclavian artery in addition to the suggestive physical findings.

  12. Prenatal Diagnosis of Treacher-Collins Syndrome Using Three-Dimensional Ultrasonography and Differential Diagnosis with Other Acrofacial Dysostosis Syndromes

    Directory of Open Access Journals (Sweden)

    Daniela Cardoso Pereira

    2013-01-01

    Full Text Available Treacher-Collins syndrome (TCS is a rare dominant autosomal anomaly resulting from malformation or disruption of the development of the first and second branchial arches. It is characterized by micrognathia, malar hypoplasia, and malformations of the eyes and ears. The prenatal diagnosis using two-dimensional ultrasonography (2DUS is characterized by identification of facial malformations together with polyhydramnios. Three-dimensional ultrasonography (3DUS has the capacity to spatially display these facial malformations, thus making it easy for the parents to understand them. We present a case of TCS diagnosed in the 33rd week using 3DUS, with postnatal confirmation using cranial computed tomography and anatomopathological analysis.

  13. Diagnostic value of ultrasonography in evaluation and management ...

    African Journals Online (AJOL)

    Results: Common causes of acute abdominal emergencies in pediatric patients as noted on ultrasonography included nonspecifi c pain (28%), abdominal abscess (21%), acute appendicitis (7%) and intussusception (7%). Ultrasonography was diagnostic in 45.2% cases and supportive in 12.3% of the cases. As for as the fi ...

  14. Nuclear medicine and ultrasonography in the acute cholecystitis diagnosis

    International Nuclear Information System (INIS)

    Schmillevitch, J.; Serson, D.; Camera, A.J.; Oliveira Nunes, J.E. de; Bazzo, J.M.B.

    1980-01-01

    Newer modalities for the evaluation of gallbladder include cholescintigraphy and ultrasonography. The IDA-Tc 99m presents functional informations with regard to cystic duct patency. The ultrasonography demonstrates the topographic anatomy of gallbladder, and morfologic alterations. Both analysis are preconized in acute cholecystitis. (Author) [pt

  15. The Place of Ultrasonography in the Evaluation of Rib Fractures

    Directory of Open Access Journals (Sweden)

    Fulya Bakılan

    2015-12-01

    Full Text Available Objective: The aim of this study was to investigate whether ultrasonography is superior to chest x-ray in detecting rib fractures in patients with minor blunt chest trauma and chest pain. Materials and Methods: Ultrasonography findings of 32 patients with minor blunt chest trauma showing no evidence of a rib fracture on anteroposterior chest x-rays, were documented. Presence of cortical discontinuities, acoustic shadows, reverberation artifacts, and hematoma by ultrasonography was proposed as the diagnostic criteria for detecting the rib fracture. Results: Rib fracture was detected in 20 patients (62.5% according to ultrasonography results. A mildly displaced fracture was detected in 7 patients (35%, hematoma was detected in 3 patients (15% and multiple fractures (in 5th, 6th, 7th, and 8th ribs were detected in 1 patient (5%. Conclusion: The results of our study showed that ultrasonography is superior to chest x-ray, in detecting rib fractures.

  16. Introital ultrasonography in female urinary incontinence

    Energy Technology Data Exchange (ETDEWEB)

    Weon, Young Cheol; Cho, Kyoung Sik; Lee, Jin Seong; Choi, Sang Hee; Kim, Keon Seok; Choo, Myung Soo [Ulsan Univ. Asan Medical Center, Seoul (Korea, Republic of)

    1996-06-01

    To evaluate the usefulness of introital ultrasonography in the assessment of female urinary incontinence. Introital ultrasonography was performed in fifteen with stress urinary incontinence(mean age 50) and six patients without symptoms of incontinence(mean age 37). Using a sagittal section of the anterior pelvis in the plane of the symphysis pubis the posterior urethrovesical angle, the pubourethral distance and the pubo-yregrak abgle were measured at rest and during stress(Valsalva's maneuver state). The student T-test and the ANOVA test were used in statistical analysis. The posterior urethrovesical angles of the controls were 125.3 deg ({+-}10.9) at rest and 125.7 deg ({+-}7.6) during stress. In the patients, the corresponding angles were 135.3 deg ({+-}11.3) and 139.6 deg({+-}10.8). The posterior urethrovesical angles increased 0.3 deg ({+-}4.7) in the controls and 5.6 deg ({+-}4.0) in the patients(p=0.018). In the controls, the pubo-urethral distances were 21.8 mm({+-}5.8) at rest and 18.2 mm({+-}7.1) during stress, while in the patients these distances were 18.4 mm({+-}3.9) and 12.6 mm({+-}4.4). The pubo-urethral distance decreased 3.5 mm ({+-}1.5) in the controls and 5.8 mm ({+-}2.3) in the patients(p=0.039). In the patients with mild incontinence(Grade I), the posterior urethrovesical angles increased 3.4 deg ({+-}2.8) : 132.3 deg ({+-}12.5) at rest and 135.6 deg (12.8) during stress. In the patients with moderate incontinence(Grade II), the angles increased 8.1 deg({+-}3.8) : 136.0 deg({+-}6.5) at rest and 144.1 deg({+-}5.9) during stress. The change of the posterior urethrovesical angle was related to the grade of urinary incontinence in the patients(p<0.05). There was no statistical significancy in the pubo-urethral angle (p=0.315). Introital ultrasonography may be useful for assessment of stress urinary incontinence.

  17. Ultrasonography of the pediatric hip and spine

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yeo Ryang; Koo, Joon Bun [Dept. of Radiology, Dongguk University Ilsan Hospital, Dongguk University College of Medicine, Goyang (Korea, Republic of)

    2017-07-15

    Ultrasonography (US) is a useful screening method for the diagnosis of developmental dysplasia of the hip (DDH) and congenital spinal anomalies in infants. In addition, US is a useful, noninvasive imaging modality for the diagnosis of transient synovitis in children. The early detection of DDH leads to a better prognosis without surgical intervention. Moreover, spinal US allows the detection of congenital malformations and can also demonstrate normal anatomy and normal variants that may resemble disorders. Therefore, radiologists should be familiar with the sonographic anatomy of the normal infant hip, scanning and measurement techniques for DDH, the US features of transient synovitis in children, spinal US techniques, and the US features of normal anatomical structures, normal variants, and congenital spinal anomalies.

  18. Current status of ultrasonography of the finger

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seun Ah; Kim, Baek Hyun [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of); Kim, Seon Jeong [Dept. of Radiology, Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Kim, Ji Na [Dept. of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon (Korea, Republic of); Park, Sun Young [Dept. of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of); Choi, Kyung Hee [Incheon Baek Hospital, Incheon (Korea, Republic of)

    2016-03-15

    The recent development of advanced high-resolution transducers has enabled the fast, easy, and dynamic ultrasonographic evaluation of small, superficial structures such as the finger. In order to best exploit these advances, it is important to understand the normal anatomy and the basic pathologies of the finger, as exemplified by the following conditions involving the dorsal, volar, and lateral sections of the finger: sagittal band injuries, mallet finger, and Boutonnière deformity (dorsal aspect); flexor tendon tears, trigger finger, and volar plate injuries (volar aspect); gamekeeper’s thumb (Stener lesions) and other collateral ligament tears (lateral aspect); and other lesions. This review provides a basis for understanding the ultrasonography of the finger and will therefore be useful for radiologists.

  19. Shoulder Ultrasonography: Performance and Common Findings

    Directory of Open Access Journals (Sweden)

    Diana Gaitini

    2012-01-01

    Full Text Available Ultrasound (US of the shoulder is the most commonly requested examination in musculoskeletal US diagnosis. Sports injuries and degenerative and inflammatory processes are the main sources of shoulder pain and functional limitations. Because of its availability, low cost, dynamic examination process, absence of radiation exposure, and ease of patient compliance, US is the preferred mode for shoulder imaging over other, more sophisticated, and expensive methods. Operator dependence is the main disadvantage of US examinations. Use of high range equipment with high resolution transducers, adhering to a strict examination protocol, good knowledge of normal anatomy and pathological processes and an awareness of common pitfalls are essential for the optimal performance and interpretation of shoulder US. This article addresses examination techniques, the normal sonographic appearance of tendons, bursae and joints, and the main pathological conditions found in shoulder ultrasonography.

  20. Current status of automated breast ultrasonography

    Directory of Open Access Journals (Sweden)

    Hee Jung Shin

    2015-07-01

    Full Text Available Breast ultrasonography (US is currently considered the first-line examination in the detection Epub ahead of print and characterization of breast lesions. However, conventional handheld US (HHUS has several limitations such as operator dependence and the requirement of a considerable amount of radiologist time for whole-breast US. Automated breast US (ABUS, recently approved by the United States Food and Drug Administration for screening purposes, has several advantages over HHUS, such as higher reproducibility, less operator dependence, and less required physician time for image acquisition. In addition, ABUS provides both a coronal view and a relatively large field of view. Recent studies have reported that ABUS is promising in US screening for women with dense breasts and can potentially replace handheld second-look US in a preoperative setting.

  1. Current status of ultrasonography of the finger

    Directory of Open Access Journals (Sweden)

    Seun Ah Lee

    2016-04-01

    Full Text Available The recent development of advanced high-resolution transducers has enabled the fast, easy, and dynamic ultrasonographic evaluation of small, superficial structures such as the finger. In order to best exploit these advances, it is important to understand the normal anatomy and the basic pathologies of the finger, as exemplified by the following conditions involving the dorsal, volar, and lateral sections of the finger: sagittal band injuries, mallet finger, and Boutonnière deformity (dorsal aspect; flexor tendon tears, trigger finger, and volar plate injuries (volar aspect; gamekeeper’s thumb (Stener lesions and other collateral ligament tears (lateral aspect; and other lesions. This review provides a basis for understanding the ultrasonography of the finger and will therefore be useful for radiologists.

  2. Ultrasonography of the pediatric hip and spine

    International Nuclear Information System (INIS)

    Kang, Yeo Ryang; Koo, Joon Bun

    2017-01-01

    Ultrasonography (US) is a useful screening method for the diagnosis of developmental dysplasia of the hip (DDH) and congenital spinal anomalies in infants. In addition, US is a useful, noninvasive imaging modality for the diagnosis of transient synovitis in children. The early detection of DDH leads to a better prognosis without surgical intervention. Moreover, spinal US allows the detection of congenital malformations and can also demonstrate normal anatomy and normal variants that may resemble disorders. Therefore, radiologists should be familiar with the sonographic anatomy of the normal infant hip, scanning and measurement techniques for DDH, the US features of transient synovitis in children, spinal US techniques, and the US features of normal anatomical structures, normal variants, and congenital spinal anomalies

  3. Prenatal diagnosis of hypophosphatasia congenita using ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Guguloth, Ashwitha [Dept. of Radiology, Bangalore Medical College and Research Institute, Bangalore (India); Aswani, Yashant; Anandpara, Karan Manoj [Dept. of Radiology, Seth G S Medical College and KEM Hospital, Mumbai (India)

    2016-01-15

    Congenital hypophosphatasia is a rare fatal skeletal dysplasia. Antenatal determinants of Epub ahead of print lethality include small thoracic circumference with pulmonary hypoplasia and severe micromelia. These features were present in the fetus of a 25-year-old female who came for an anomaly scan in her second trimester of pregnancy. Additional findings of generalized demineralization and osteochondral spurs led to the diagnosis of hypophosphatasia congenita. The pregnancy was terminated, and the findings were confirmed on autopsy. Common differential diagnoses with clues to diagnose the above mentioned condition have been discussed here. Early and accurate detection of this medical condition is important as no treatment has been established for this condition. Therefore, antenatal ultrasonography helps in diagnosing and decision making with respect to the current pregnancy and lays the foundation for the genetic counseling of the couple.

  4. [Overal cognitive assessment in Basque-speaking people with advanced dementia. Validation to the Basque language of the Severe Mini-Mental State Examination SMMSE (SMMSE-eus)].

    Science.gov (United States)

    Buiza, Cristina; Yanguas, Javier; Zulaica, Amaia; Antón, Iván; Arriola, Enrique; García, Alvaro

    2018-04-13

    Adaptation and validation to the Basque language of tests to assess advanced cognitive impairment is a not covered need for Basque-speaking people. The present work shows the validation of the Basque version of the Severe Mini Mental State Examination (SMMSE). A total of 109 people with advanced dementia (MECinternal consistency (alpha=0.92), a good test-retest reliability (r=0.88; Pinternal consistency and inter-rater reliability, and to a lesser extent, test-retest reliability, made the SMMSE-eus a valid test for the brief assessment of cognitive status in people with advanced dementia in Basque-speaking people. For this reason, the SMMSE-eus is a usable and reliable alternative for assessing Basque-speaking people in their mother-tongue, or preferred language. Copyright © 2017 SEGG. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Identifying indications for percutaneous (PTC) vs. endoscopic ultrasound (EUS)- guided "rendezvous" procedure in biliary obstruction and incomplete endoscopic retrograde cholangiography (ERC).

    Science.gov (United States)

    Albert, J G; Finkelmeier, F; Friedrich-Rust, M; Kronenberger, B; Trojan, J; Zeuzem, S; Sarrazin, C

    2014-10-01

    The variety of rendezvous (RV) procedures has recently been extended by EUS- and PTCD-guided procedures as a complementary means to conventional ERCP. We have identified indication criteria and the potential of biliary PTCD-guided vs. EUS-guided RV. Consecutive patients with bile duct obstruction who underwent RV were included. In all, ERCP alone was unable to achieve treatment success. Indication, technical success, and outcome in PTCD- vs. EUS-guided RV were retrospectively compared to identify criteria that indicate preference of RV technique. Site of obstruction, clinical scenario (stenosis with abscess vs. no abscess) and reason for previous failure of ERC were evaluated. In 32 patients, three different indications for RV procedures were identified: First, a one-step access to assist in failed ERCP (type 1, intra-ductal RV); second, temporary drainage for prolonged treatment of complex biliary disease (type 2, intra-ductal RV), and drainage of cholangio-abscess with re-establishing bile outflow (type 3, intra-abscess RV). Indication of PTCD- vs. EUS-guided rendezvous was competitive in type 1, but exclusive in favor of PTCD in types 2 and 3. The site of biliary obstruction indicated the anatomic location of RV procedures. This classification may help to define inclusion criteria for prospective studies on biliary RV procedures. Choice of therapeutic strategy depends on the anatomic location of the biliary obstruction and the type of the biliary lesion. PTCD-guided RV might improve outcome in cholangio-abscess. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Compression ultrasonography of the lower extremity with portable vascular ultrasonography can accurately detect deep venous thrombosis in the emergency department.

    Science.gov (United States)

    Crisp, Jonathan G; Lovato, Luis M; Jang, Timothy B

    2010-12-01

    Compression ultrasonography of the lower extremity is an established method of detecting proximal lower extremity deep venous thrombosis when performed by a certified operator in a vascular laboratory. Our objective is to determine the sensitivity and specificity of bedside 2-point compression ultrasonography performed in the emergency department (ED) with portable vascular ultrasonography for the detection of proximal lower extremity deep venous thrombosis. We did this by directly comparing emergency physician-performed ultrasonography to lower extremity duplex ultrasonography performed by the Department of Radiology. This was a prospective, cross-sectional study and diagnostic test assessment of a convenience sample of ED patients with a suspected lower extremity deep venous thrombosis, conducted at a single-center, urban, academic ED. All physicians had a 10-minute training session before enrolling patients. ED compression ultrasonography occurred before Department of Radiology ultrasonography and involved identification of 2 specific points: the common femoral and popliteal vessels, with subsequent compression of the common femoral and popliteal veins. The study result was considered positive for proximal lower extremity deep venous thrombosis if either vein was incompressible or a thrombus was visualized. Sensitivity and specificity were calculated with the final radiologist interpretation of the Department of Radiology ultrasonography as the criterion standard. A total of 47 physicians performed 199 2-point compression ultrasonographic examinations in the ED. Median number of examinations per physician was 2 (range 1 to 29 examinations; interquartile range 1 to 5 examinations). There were 45 proximal lower extremity deep venous thromboses observed on Department of Radiology evaluation, all correctly identified by ED 2-point compression ultrasonography. The 153 patients without proximal lower extremity deep venous thrombosis all had a negative ED compression

  7. A Comparison of Endoscopic Ultrasound Guided Biopsy and Positron Emission Tomography with Integrated Computed Tomography in Lung Cancer Staging

    DEFF Research Database (Denmark)

    Larsen, Stine Schmidt; Vilmann, P; Krasnik, K

    2009-01-01

    BACKGROUND AND STUDY AIMS: Exact staging of patients with non-small-cell lung cancer (NSCLC) is important to improve selection of resectable and curable patients for surgery. Positron emission tomography with integrated computed tomography (PET/CT) and endoscopic ultrasound guided fine needle...... aspiration biopsy (EUS-FNA) are new and promising methods, but indications in lung cancer staging are controversial. Only few studies have compared the 2 methods. The aim of this study was to assess and compare the diagnostic values of PET/CT and EUS-FNA for diagnosing advanced lung cancer in patients, who...... had both procedures performed. PATIENTS AND METHODS: 27 patients considered to be potential candidates for resection of NSCLC underwent PET/CT and EUS-FNA. Diagnoses were confirmed either by open thoracotomy, mediastinoscopy or clinical follow-up. Advanced lung cancer was defined as tumour...

  8. Correlation theory applied to the static and dynamic properties of EuO and EuS

    International Nuclear Information System (INIS)

    Lindgard, P.A.

    1981-10-01

    The paramagnetic scattering was recently measured for EuO. It was found that spin-wave-like excitations develop for wave vectors approaching the zone boundary. The spectrum was found to be well described by damped harmonic oscillators (also called the two-pole-approximation). This approximation was used previously in the correlation theory primarily to calculate static properties. Selfconsistent dynamic and static calculations have been performed for EuO, which is an ideal Heisenberg magnet with significant second nearest neighbor interaction (J 2 = J/sub 1/5). The two-pole approximation describes accurately the correlation range, the static susceptibility and the qualitative behavior of the dynamic properties (i.e., the wave vector at which peaks appear in the spectrum as a function of temperature). However, in order to also obtain the correct frequency scale it is necessary to use a cut-off of the spectrum at high frequencies, which cannot be seen experimentally, but which significantly influences the frequency moments. It was found that the finite J 2 has significant importance for a comparison between theory and experiment. It is concluded that the calculation for a simple cubic n.n. magnet by Hubbard does not describe the EuO data accurately, neither with respect to lineshape nor frequency scale. Significant differences are to be expected between EuO and EuS having opposite sign for J 2

  9. Characterisation of focal liver lesions with contrast enhanced ultrasonography

    International Nuclear Information System (INIS)

    Dietrich, Christoph F.

    2004-01-01

    Ultrasound contrast agents (USCA) have improved the detection rate of liver tumours in recent years. Conventional ultrasound has been reported to be relatively unreliable in the characterisation of liver tumours. SonoVue [reg] (Bracco Imaging Spa) has been shown to be particularly advantageous in the differentiation of benign and malignant liver tumours and, therefore, possibly represents a new cost-effective competitive alternative to other liver imaging modalities (e.g. computed tomography and magnetic resonance imaging), thus allowing these important technologies to be available for other indications (e.g. brain, thorax). More detailed and specific liver tumour characterisation is possible in about 80% of liver tumours due to typical vascularity and perfusion patterns. The role of USCA for better characterisation, which is possible through the analysis of flow characteristics in real time, places a particular emphasis on agent use. Contrast enhanced real-time imaging techniques with SonoVue [reg] allow real-time analysis of tumour perfusion in patients with liver lesions. Liver tumours known to be hyperperfused in the arterial phase (e.g. focal nodular hyperplasia, hepatocellular adenoma and carcinoma, and hyperperfused metastases) can be better detected and characterised. Hypoperfused tumours (e.g. liver metastases of the gastrointestinal tract) can be recognised in the portal venous phase as less perfused 'black spots'. In this article we discuss liver tumour characterisation by contrast enhanced ultrasonography

  10. Duplex Ultrasonography Has Limited Utility in Detection of Postoperative DVT After Primary Total Joint Arthroplasty.

    Science.gov (United States)

    Vira, Shaleen; Ramme, Austin J; Alaia, Michael J; Steiger, David; Vigdorchik, Jonathan M; Jaffe, Frederick

    2016-07-01

    Duplex ultrasound is routinely used to evaluate suspected deep venous thrombosis after total joint arthroplasty. When there is a clinical suspicion for a pulmonary embolism, a chest angiogram (chest CTA) is concomitantly obtained. Two questions were addressed: First, for the population of patients who receive duplex ultrasound after total joint arthroplasty, what is the rate of positive results? Second, for these patients, how many of these also undergo chest CTA for clinical suspicion of pulmonary embolus and how many of these tests are positive? Furthermore, what is the correlation between duplex ultrasound results and chest CTA results? A retrospective chart review was conducted of total joint replacement patients in 2011 at a single institution. Inclusion criteria were adult patients who underwent a postoperative duplex ultrasonography for clinical suspicion of deep venous thrombosis (DVT). Demographic data, result of duplex scan, clinical indications for obtaining the duplex scan, and DVT prophylaxis used were recorded. Additionally, if a chest CTA was obtained for clinical suspicion for pulmonary embolus, results and clinical indication for obtaining the test were recorded. The rate of positive results for duplex ultrasonography and chest CTA was computed and correlated based on clinical indications. Two hundred ninety-five patients underwent duplex ultrasonography of which only 0.7% were positive for a DVT. One hundred three patients underwent a chest CTA for clinical suspicion of a pulmonary embolism (PE) of which 26 revealed a pulmonary embolus, none of which had a positive duplex ultrasound. Postoperative duplex scans have a low rate of positive results. A substantial number of patients with negative duplex results subsequently underwent chest CTA for clinical suspicion for which a pulmonary embolus was found, presumably resulting from a DVT despite negative duplex ultrasound result. A negative duplex ultrasonography should not rule out the presence of a

  11. Endoscopic Ultrasonography in the Diagnosis of Gastric Subepithelial Lesions

    Directory of Open Access Journals (Sweden)

    Eun Jeong Gong

    2016-09-01

    Full Text Available Subepithelial lesions occasionally found in the stomach of patients undergoing endoscopy may be either benign lesions or tumors with malignant potential. They may also appear due to extrinsic compression. Discrimination of gastric subepithelial lesions begins with meticulous endoscopic examination for size, shape, color, mobility, consistency, and appearance of the overlying mucosa. Accurate diagnosis can be achieved with endoscopic ultrasonography, which provides useful information on the exact size, layer-of-origin, and characteristic morphologic features to support a definitive diagnosis. Endoscopic ultrasonography also aids in the prediction of malignant potential, especially in gastrointestinal stromal tumors. Features of subepithelial lesions identified on endoscopic ultrasonography can be used to determine whether further diagnostic procedures such as endoscopic resection, fine needle aspiration, or core biopsy are required. Endoscopic ultrasonography is a valuable tool for diagnosis and clinical decision making during follow-up of gastric subepithelial lesions.

  12. Normal values for quantitative muscle ultrasonography in adults.

    NARCIS (Netherlands)

    Arts, I.M.P.; Pillen, S.; Schelhaas, H.J.; Overeem, S.; Zwarts, M.J.

    2010-01-01

    Ultrasonography can detect structural muscle changes caused by neuromuscular disease. Quantitative analysis is the preferred method to determine if ultrasound findings are within normal limits, but normative data are incomplete. The purpose of this study was to provide normative muscle

  13. Ultrasonography as a diagnostic method in addition to mammography

    Energy Technology Data Exchange (ETDEWEB)

    Otto, H.; Roer, E.

    1988-05-01

    By using ultrasonography in addition to mammography, experienced diagnosticians essentially enhance the safety of their diagnosis of mammary gland diseases. The same applies to gynecomastia, the condition after plastic surgery, and mastitis.

  14. Ultrasonography as a better diagnostic efficiency in rib fracture

    OpenAIRE

    UZUN, Metin; BEKSAÇ, Burak; KARATAŞ, Adnan; KÜÇÜKDURMAZ, Fatih; KIRCALI, Bahar ANAYURDU; TETİK, Cihangir

    2013-01-01

    In this study, our aim was to demonstrate the need of use of ultrasonography in rib fractures in order not to face medicolegal problems. One hundred patients admitted to our emergency service with mild to moderate blunt thorax trauma were included in our study prospectively. The inclusion criteria were pain upon palpation of ribs, deep inspiration, coughing but no any other pathologies like a pneumothorax, hemothorax. All patients are evaluated with ultrasonography (USG) and direct X-rays. X-...

  15. Ultrasonography of the lower extremity veins: Anatomy and basic approach

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Kyu; Ahn, Kyung Sik; Kang, Chang Ho; Cho, Sung Bum [Dept. of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Ultrasonography is an imaging modality widely used to evaluate venous diseases of the lower extremities. It is important to understand the normal venous anatomy of the lower extremities, which has deep, superficial, and perforating venous components, in order to determine the pathophysiology of venous disease. This review provides a basic description of the anatomy of the lower extremity veins and useful techniques for approaching each vein via ultrasonography.

  16. Intraoperative ultrasonography in detection of hepatic metastases from colorectal cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael; Kronborg, Ole; Fenger, Claus

    1995-01-01

    PURPOSE: This study was designed to compare diagnostic accuracies of measuring liver enzymes, preoperative ultrasonography, surgical examination, and intraoperative ultrasonography for detection of liver metastases from colorectal cancer. METHODS: Blind, prospective comparisons of diagnostic...... examinations mentioned above were performed in 295 consecutive patients with colorectal cancer. An experienced ultrasonologist performed the preoperative examinations, and results were unknown to the other experienced ultrasonologist who performed the intraoperative examinations. The latter, also was unaware...

  17. Ultrasonography of the lower extremity veins: Anatomy and basic approach

    International Nuclear Information System (INIS)

    Lee, Dong Kyu; Ahn, Kyung Sik; Kang, Chang Ho; Cho, Sung Bum

    2017-01-01

    Ultrasonography is an imaging modality widely used to evaluate venous diseases of the lower extremities. It is important to understand the normal venous anatomy of the lower extremities, which has deep, superficial, and perforating venous components, in order to determine the pathophysiology of venous disease. This review provides a basic description of the anatomy of the lower extremity veins and useful techniques for approaching each vein via ultrasonography

  18. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  19. Ultrasonography of hydronephrosis and renal masses

    International Nuclear Information System (INIS)

    Lee, Kyung Weon; Kim, Chong Gun; Kim, Yeon Jin; Rhee, Byung Chull

    1984-01-01

    We have analyzed ultrasonographic findings of 55 cases of hydronephrosis and 34 cases of renal masses. The results are as follows: 1. 55 cases of hydronephrosis revealed renal enlargement in 55 cases, separation of central echo complex in 27 cases, multiple anechoic areas radiating from the center in 25 cases and dilated renal pelvis in 24 cases. 2. Among the masses in 34 cases, simple renal cyst were 15 cases, polycystic kidney in 8 cases, hypernephroma in 8 cases, Wilm's tumor in 2 cases and agiomyolipoma in 1 case. 3. Simple renal cyst revealed single in 14 cases (93%) and well defined anechoic mass with posterior enhancement in all cases. 4. Polycystic kidney revealed bilateral irregular shaped renal enlargement and multiple anechoic cysts throughout the kidney. 2 cases (25%) involved liver. 5. 6 cases (75%) of hypernephroma revealed ill defined moderately echogenic mass without posterior enhancement. 6. All cases of Wilm's tumor revealed well defined large mixed echogenic mass in right kidney. 7. Angiomyolipoma revealed bilateral dense echogenic mass with large hemorrhage cyst in right kidney. 8. The ultrasonography is useful noninvasive diagnostic modality of evaluation of renal masses and hydronephrosis.

  20. En bloc kidney transplantation: ultrasonography assessment

    International Nuclear Information System (INIS)

    Arenal, F.; Ganado, T.; Merino, M.S.; Contreras, E.; Hernandez, J.; Prats, D.

    1997-01-01

    The objective of our study is to assess the utility of ultrasonography in the study of the complications associated with en bloc kidney transplantation. Twenty-three recipients of double transplants from donors under the age of 3 years were studied. Ultrasound (mode B: pulsed Doppler and color Doppler) was performed within the first three postoperative days and was repeated at 6 and 12 months. The morphology of the graft and renal blood flow were assessed, and the indices of pulsatility, resistance and acceleration were measured. Four patients required graft explanation: three due to massive hemorrhagic infarction and one due to venous thrombosis. Vascular complications were detected in five transplants (21.7%), urological complications in four (17.4%) and medical complications in two (8.7%). The most common vascular complication was unilateral renal artery stenosis. Color Doppler ultrasound diagnosed all the medical and urological complications and three of the five cases of vascular pathology (60%). Renal size was seen to be increased during the first postoperative year. The ultrasonographic study is more difficult to perform in en bloc kidney transplantation than in single kidney grafting: however, given its marked sensitivity in the detection of postransplantation complications. Doppler ultrasound is the imaging technique of choice in the determination of the cause of deteriorated kidney function. (Author) 15 refs

  1. Prospective evaluation of yield of endoscopic ultrasonography in the etiological diagnosis of "idiopathic" acute pancreatitis

    Directory of Open Access Journals (Sweden)

    Narendra S Choudhary

    2016-01-01

    Full Text Available Background: Etiology of acute pancreatitis (AP remains idiopathic in 30% of patients. Endoscopic ultrasound (EUS has been shown to increase the diagnostic yield in patients with idiopathic AP (IAP. Aim: The aim of this study was to evaluate the role of EUS in achieving etiological diagnosis in patients with IAP. Materials and Methods: Consecutive 192 patients with IAP were evaluated prospectively with EUS over a period of 2 years. Patients who had no etiological diagnosis for AP after detailed history, clinical examination, laboratory investigations, and magnetic resonance cholangiopancreatography were included in the study. Results: The mean age of patients was 34.6 ± 12 and male:female ratio was 2.1:1. Of these, 135 patients had gallbladder intact (Group A and 57 patients had undergone cholecystectomy (Group B. In Group A, EUS identified a possible cause in 79 (58.5% patients; microlithiasis (n = 48, chronic pancreatitis (CP (n = 23, common bile duct (CBD and gallbladder stone (n = 3, pancreatic divisum (n = 3, small pancreatic tumor (n = 1, and anomalous pancreaticobiliary junction (n = 1. In Group B, EUS yielded diagnosis in 28 (49.1% patients; CP (n = 22, ascariasis (n = 3, CBD stone (n = 2, and pancreatic divisum (n = 1. Overall EUS helped in achieving etiological diagnosis in 107 (55.1% of patients with IAP. The presence of intact gallbladder showed a tendency for increased diagnostic yield (P = 0.06. Conclusion: EUS is a useful modality to establish the diagnosis in IAP and this technique should be incorporated in the evaluation of IAP.

  2. Serial 2-point ultrasonography plus D-Dimer vs whole-leg color-coded doppler ultrasonography for diagnosing suspected symptomatic deep vein thrombosis - A randomized controlled trial

    NARCIS (Netherlands)

    Bernardi, Enrico; Camporese, Giuseppe; Buller, Harry R.; Siragusa, Sergio; Imberti, Davide; Berchio, Arrigo; Ghirarduzzi, Angelo; Verlato, Fabio; Anastasio, Raffaela; Prati, Carolina; Piccioli, Andrea; Pesavento, Raffaele; Bova, Carlo; Maltempi, Patrizia; Zanatta, Nello; Cogo, Alberto; Cappelli, Roberto; Bucherini, Eugenio; Cuppini, Stefano; Noventa, Franco; Prandoni, Paolo

    2008-01-01

    Context Patients with suspected deep vein thrombosis ( DVT) of the lower extremities are usually investigated with ultrasonography either by the proximal veins ( 2-point ultrasonography) or the entire deep vein system ( whole- leg ultrasonography). The latter approach is thought to be better based

  3. Granulomatous Prostatitis: Gray-scale Transrectal Ultrasonography and Color Doppler Ultrasonography Findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Jung; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae; Kim, Eui Jong [Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2007-12-15

    We report here three cases of granulomatous prostatitis. All cases were confirmed by a transrectal ultrasonography (TRUS)-guided core biopsy of the prostate. Two cases received intravesical BCG therapy for a bladder tumor, and one case had no known predisposing condition. Gray-scale TRUS showed low echoic nodules in the outer gland in all cases. Color Doppler ultrasonography (CDUS) showed several dot-like blood flows within the low echoic nodules in two cases and several dot-like blood flows and short linear blood flows within the low echoic nodules in one case. Gray-scale TRUS findings of granulomatous prostatitis are similar to findings of prostate cancer. On CDUS, several dot-like blood flows or short linear blood flows were noted within the low echoic nodules in patients with granulomatous prostatitis. If low echoic nodules with dot-like or short linear blood flows are noted in patients with genitourinary tract tuberculosis or previous BCG therapy, granulomatous prostatitis should be included in the differential diagnosis. However, a prostatic biopsy is required for a final diagnosis

  4. An analysis of 1018 cases of ultrasonography

    International Nuclear Information System (INIS)

    Kim, Chu Wan; Suh, Jeong Soo; Lee, Kwan Seh; Kim, Ki Hwan; Im, Chung Gie; Chang, Kee Hyun; Yeon, Kyung Mo; Han, Man Chung; Choo, Dong Woon

    1985-01-01

    Ultrasound is an especially helpful diagnostic tool in assessing various diseases in various organs as well as differentiating cystic masses from solid ones, with ease safety, reproducibility, and high accuracy. Authors analyzed total 1018 cases of ultrasonography that were studied in last seven months from March. 15. 1979 to October. 31. 1979, at the Department of Radiology, Seoul National University Hospital. The results were as follows: 1. Among the 1018 cases, 421 cases were male and 597 cases of female. The age distribution was from several months to 83 years, and 88% of all cases were in 20 to 69 years of age. 2. Sites of scanning; Liver, G.B. and biliary systems 376, thyroid 185, kidney 192, pelvis 121, abdomen 70, pancreas 48, eyeball 14, and other 12. 3. Hepatobiliary system 376; Normal 174, hepatomegaly 12, hepatoma 7, metastases 6, abscess 6, cirrhosis 2, hepatic cyst 1, hemangioma 1, agenesis of left lobe 1. 4. G.B. stones 106, cholecystitis 35, biliary tree dilatation 13, enlarged G.B. 7, C.B.D. stone 5, cystic duct stone 4, C.B.D. cancer 6, G.B. cancer 1, choledochal cyst 1, non-visualized G.B. 8. 5. Thyroid, 185; Nodule 147 -- solid 56, cystic 70, complex 21, Diffuse enlargement 29, normal scan 7, unidentified 2. 6. Pancreas, 48; Normal 17, pancreastitis 4, pancreatic cancer 22, pseudocyst 4, unidentified 1. 7. Abdomen 77 (excluding liver, G.B. and pancreas); Normal scan 31, solid tumor 14 - lymphoma group 12, mesenchyma origin 2, multiple lymph node enlargement 13, aortic aneurysm 4, retroperitoneal mass 2, subphrenic abscess 2, abdominal wall abscess 2, unknown solid mass 4, not contributory 4. 8. Kidney, 194, Normal scan 44, size and markings for biopsy 75, hydronephrosis 21, renal cyst 8, polycystic disease 8, solid renal tumor 10, renal stone 7, agenesis or hypoplasia 2, contracted kidney, both 7, enlarge kidney due to lymphoma and compensatory hyperplasia 5, renal tbc 2, perirenal abscess 1, perirenal hematoma 1, movable kidney 1, bladder tumor

  5. Evaluation of Snake Bites with Bedside Ultrasonography

    Directory of Open Access Journals (Sweden)

    Josef E Jolissaint

    2018-04-01

    Full Text Available History of present illness: While watering his lawn, a 36-year-old man felt two sharp bites to his bilateral ankles. He reports that he then saw a light brown, 2-foot snake slither away from him. He came to the emergency department because of pain and swelling in his ankles and inability to bear weight. Physical examination revealed bilateral ankle swelling and puncture marks on his left lateral heel and medial right ankle. Palpation, passive flexion and extension elicited severe pain bilaterally. Blood work including prothrombin time (PT, partial thromboplastin time (PTT, international normalized ratio (INR, and fibrinogen were within normal limits. Consultation with Poison Control indicated the snake was likely a copperhead, which is a venomous snake whose bites rarely require antivenin. Significant findings: In this case, ultrasonography of the lateral surface of the left foot revealed soft tissue edema (red arrow and fluid collection (white asterisk adjacent to the extensor tendon (white arrow. The edematous area resembles cobblestones, with hypoechoic areas of fluid spanning relatively hyperechoic fat lobules. The tendon is surrounded by anechoic fluid, expanding the potential space in the sheath. No hyperechoic foreign objects were noted. Discussion: The patient was diagnosed with soft tissue injury and extensor tenosynovitis after a snake envenomation. Snake venom contains metalloproteinases and other enzymatic proteins that cause local tissue edema and necrosis.1 After a snake bite, ultrasound can be used to assess for retained fangs, soft tissue edema, tendon sheath fluid, muscle fasciculation, and injury to deeper musculature that may not be readily apparent on physical exam.2,3 Most patients with tenosynovitis will recover with immobilization of the joint and non-steroidal anti-inflammatory medications.4 Rarely, the tendon may become infected requiring antibiotics and surgical intervention.4 Topics: Ultrasound, snake envenomation

  6. Ultrasonography in Gastroenterology: The Need for Training

    Directory of Open Access Journals (Sweden)

    João Pinto

    2018-02-01

    Full Text Available The use of ultrasonography (US as an imaging modality in medicine has spread across almost every clinical specialty. This diffusion is based on the simplicity, accessibility, portability and affordability of the technique producing real-time high-resolution images using non-ionising radiation. On the other hand, this trend also extended the technique to settings other than healthcare, such as public facilities, private houses or remote sites. This tendency can be observed worldwide, from developing countries to prestigious medical schools and tertiary referral hospitals. Furthermore, point-of-care US (POCUS, i.e., US executed at the patient’s bedside to obtain real-time objective information with diagnostic and clinical monitoring purposes or to guide invasive procedures, has been incorporated in many specialties. In gastroenterology, despite the essential role of endoscopy, clinical practice is highly dependent on non-endoscopic imaging techniques. However, as in other specialties, the indications of US in gastroenterology have been increasing steadily, covering a broad range of conditions. In response to the generalised employment of US by non-radiologists, institutions such as the European Federation of Societies for Ultrasound in Medicine and Biology and the Royal College of Radiologists issued recommendations to ensure high-quality practice. These theoretical and practical requisites include performing a certain number of examinations and mandatory skills in order to achieve certification to execute unsupervised US. Therefore, there is a need for modern gastroenterology to include US as a basic skill in its clinical practice. To ensure the provision of high-quality US, adequate instruction of future specialists should be guaranteed by the gastroenterology departments and required in the residency training programme.

  7. Evaluation of normal masseter muscles on ultrasonography

    International Nuclear Information System (INIS)

    Hwang, Hyoung Zoo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2008-01-01

    To assess the internal echo intensity and morphological variability of masseter muscles on ultrasonography and to establish diagnostic criterion of estimation. Participants consisted of 50 young adults (male 25, female 25) without pathologic conditions and with full natural dentitions. Sonographic examinations were done with real time ultrasound equipment as Logiq 500 (GE Medical Systems, Seoul, Korea) at 3 parts according to lines paralleling with ala-tragus line as reference line. The thickness and area of masseter muscles according to reference line in cross-sectional images were measured at rest and at maximum contraction. The visibility and width of the internal echogenic intensity of the masseter muscles were also assessed and the muscle appearance was classified into 4 types. Data were statistically analyzed by paired t-test and x2-test. 1. When comparing the thickness and area of masseter muscles concerning with gender, there was few significant difference between right and left sides, however, there were significant differences between males and females except for the greatest thickness of left side. 2. The changes of the greatest thickness and the area between rest and maximum contraction showed that the part of the least thickness manifested more increase at maximum contraction. 3. Each part the manifestations of the internal echogenic intensity of the masseter muscles were different depending on the locations. But there was no statistically significance. Changes of muscles thickness with contraction and internal echogenic intensity with locations showed great disparity within the masseter muscles, which will be diagnostic criteria for pathophysiologic and anatomic changes of masseter muscles.

  8. Role of endoscopic ultrasonography in the loco-regional staging of patients with rectal cancer

    Science.gov (United States)

    Marone, Pietro; de Bellis, Mario; D’Angelo, Valentina; Delrio, Paolo; Passananti, Valentina; Di Girolamo, Elena; Rossi, Giovanni Battista; Rega, Daniela; Tracey, Maura Claire; Tempesta, Alfonso Mario

    2015-01-01

    The prognosis of rectal cancer (RC) is strictly related to both T and N stage of the disease at the time of diagnosis. RC staging is crucial for choosing the best multimodal therapy: patients with high risk locally advanced RC (LARC) undergo surgery after neoadjuvant chemotherapy and radiotherapy (NAT); those with low risk LARC are operated on after a preoperative short-course radiation therapy; finally, surgery alone is recommended only for early RC. Several imaging methods are used for staging patients with RC: computerized tomography, magnetic resonance imaging, positron emission tomography, and endoscopic ultrasound (EUS). EUS is highly accurate for the loco-regional staging of RC, since it is capable to evaluate precisely the mural infiltration of the tumor (T), especially in early RC. On the other hand, EUS is less accurate in restaging RC after NAT and before surgery. Finally, EUS is indicated for follow-up of patients operated on for RC, where there is a need for the surveillance of the anastomosis. The aim of this review is to highlight the impact of EUS on the management of patients with RC, evaluating its role in both preoperative staging and follow-up of patients after surgery. PMID:26140096

  9. Diagnostic Accuracy of Ultrasonography and Radiography in Initial Evaluation of Chest Trauma Patients.

    Science.gov (United States)

    Vafaei, Ali; Hatamabadi, Hamid Reza; Heidary, Kamran; Alimohammadi, Hosein; Tarbiyat, Mohammad

    2016-01-01

    Application of chest radiography for all multiple trauma patients is associated with a significant increase in total costs, exposure to radiation, and overcrowding of the emergency department. Ultrasound has been introduced as an alternative diagnostic tool in this regard. The aim of the present study is to compare the diagnostic accuracy of chest ultrasonography and radiography in detection of traumatic intrathoracic injuries. In the present prospective cross-sectional study, patients with traumatic intrathoracic injuries, who were referred to the emergency department from December 2013 to December 2014, were assessed. The patients underwent bedside ultrasound, radiographic and computed tomography (CT) scan examinations based on ATLS recommendations. Screening performance characteristics of ultrasonography and radiography were compared using SPSS 21.0. Chest CT scan was considered as gold standard. 152 chest trauma patients with a mean age of 31.4 ± 13.8 years (range: 4 ‒ 67), were enrolled (77.6% male). Chest CT scan showed pulmonary contusion in 48 (31.6%) patients, hemothorax in 29 (19.1%), and pneumothorax in 55 (36.2%) cases. Area under the ROC curve of ultrasonography in detection of pneumothorax, hemothorax, and pulmonary contusion were 0.91 (95% CI: 0.86‒0.96), 0.86 (95% CI: 0.78‒0.94), and 0.80 (95% CI: 0.736‒0.88), respectively. Area under the ROC curve of radiography was 0.80 (95% CI: 0.736‒0.87) for detection of pneumothorax, 0.77 (95% CI: 0.68‒0.86) for hemothorax, and 0.58 (95% CI: 0.5‒0.67) for pulmonary contusion. Comparison of areas under the ROC curve declared the significant superiority of ultrasonography in detection of pneumothorax (p = 0.02) and pulmonary contusion (p < 0.001). However, the diagnostic value of the two tests was equal in detection of hemothorax (p = 0.08). The results of the present study showed that ultrasonography is preferable to radiography in the initial evaluation of patients with traumatic injuries to the

  10. Diagnostic Accuracy of Ultrasonography and Radiography in Initial Evaluation of Chest Trauma Patients

    Directory of Open Access Journals (Sweden)

    Ali Vafaei

    2016-01-01

    Full Text Available Introduction: Application of chest radiography for all multiple trauma patients is associated with a significant increase in total costs, exposure to radiation, and overcrowding of the emergency department. Ultrasound has been introduced as an alternative diagnostic tool in this regard. The aim of the present study is to compare the diagnostic accuracy of chest ultrasonography and radiography in detection of traumatic intrathoracic injuries. Methods: In the present prospective cross-sectional study, patients with traumatic intrathoracic injuries, who were referred to the emergency department from December 2013 to December 2014, were assessed. The patients underwent bedside ultrasound, radiographic and computed tomography (CT scan examinations based on ATLS recommendations. Screening performance characteristics of ultrasonography and radiography were compared using SPSS 21.0. Chest CT scan was considered as gold standard. Results: 152 chest trauma patients with a mean age of 31.4 ± 13.8 years (range: 4 ‒ 67, were enrolled (77.6% male. Chest CT scan showed pulmonary contusion in 48 (31.6% patients, hemothorax in 29 (19.1%, and pneumothorax in 55 (36.2% cases. Area under the ROC curve of ultrasonography in detection of pneumothorax, hemothorax, and pulmonary contusion were 0.91 (95% CI: 0.86‒0.96, 0.86 (95% CI: 0.78‒0.94, and 0.80 (95% CI: 0.736‒0.88, respectively. Area under the ROC curve of radiography was 0.80 (95% CI: 0.736‒0.87 for detection of pneumothorax, 0.77 (95% CI: 0.68‒0.86 for hemothorax, and 0.58 (95% CI: 0.5‒0.67 for pulmonary contusion. Comparison of areas under the ROC curve declared the significant superiority of ultrasonography in detection of pneumothorax (p = 0.02 and pulmonary contusion (p < 0.001. However, the diagnostic value of the two tests was equal in detection of hemothorax (p = 0.08. Conclusion: The results of the present study showed that ultrasonography is preferable to radiography in the initial

  11. Usefulness of endoscopic ultrasonography in the clinical suspicion of biliary disease Utilidad de la ultrasonografía endoscópica en la sospecha clínica de patología biliar

    Directory of Open Access Journals (Sweden)

    David del Pozo

    2011-07-01

    Full Text Available Background and aims: endoscopic ultrasound (EUS is a very sensitive and specific technique for the diagnosis of biliary diseases. This procedure has proven its usefulness in cases of high suspicion of biliary disease (history of gallstones and dilatation of the intrahepatic and/or extrahepatic bile ducts. We know less about its usefulness in cases of low suspicion of biliary pathology. The aim of this study was to assess the diagnostic accuracy of EUS in patients with low suspicion of biliary disease (patients with dilatation of the biliary tract were excluded. Methods: 33 patients with low suspicion of biliary disease were recruited in 12 months. All of them had no biliary findings in a previous abdominal ultrasound and computer tomography scan. All of them underwent EUS and were studied prospectively. The diagnosis was confirmed by surgery and/or by ERCP in patients with positive EUS or clinical follow-up in those with normal EUS. Time of follow-up was 9 months (range, 3-12 months. Results: seventeen patients (51.5% presented with abnormal biliary findings on EUS (7 choledocholithiasis, 3 cholelithiasis, 2 choledocholithiasis + cholelithiasis and 5 microlithiasis. Conclusion: EUS is a useful and safe procedure for diagnosing patients with low suspicion of biliary disease.Antecedentes y objetivos: la ultrasonografía endoscópica (USE es una técnica muy sensible y específica para el diagnóstico de enfermedades biliares. Este procedimiento ha demostrado su utilidad en casos de alta sospecha de enfermedad biliar (historia de colelitiasis y dilatación de la vía biliar intra- y/o extrahepática. Sabemos menos sobre su utilidad en casos de baja sospecha de patología biliar. El objetivo de este estudio fue evaluar la precisión diagnóstica de la USE en pacientes con baja sospecha de enfermedad biliar (los pacientes con dilatación de la vía biliar fueron excluidos. Métodos: 33 pacientes con baja sospecha de enfermedad biliar fueron

  12. Transvaginal ultrasonography in first trimester of pregnancy and its comparison with transabdominal ultrasonography

    Directory of Open Access Journals (Sweden)

    Aneet Kaur

    2011-01-01

    Full Text Available Objectives : Examination of pregnant women in the first trimester with transvaginal ultrasonography with the aim to study various fetal development markers, e.g., gestation sac, yolk sac, fetal heart motion, CRL length, and fetal anatomy in both normal and abnormal pregnancies. Comparative evaluation of transvaginal ultrasonography vis-ΰ-vis transabdominal scanning in the study of first trimester of pregnancy and its complications. To assess the relative merits and demerits of transvaginal ultrasonography in comparison with the transabdominal technique. Materials and Methods : The study will be conducted on 50 females patients during the first trimester of pregnancy. The study population will consist of both normal and abnormal pregnancies. These patients will be included on the basis of suspicion of or proven pregnancy of duration up to 12 weeks from LMP. The evaluation of the patients will include the following: Record of patients obstetrical history and clinical examination, record of pregnancy test and relevant investigations, ultrasonic examination of pregnancy. (a Transabdominal ultrasound scanning will be done with moderately distended bladder by using real time scanners with low frequency probe (3/3.5 MHz; (b transvaginal sonography will be done with the real-time sector scanner using high-frequency endovaginal probe (5/7.5 MHz, after the patient voids urine. Relevant images will be taken by using the multiformat automatic camera. Results and Conclusions : In the study of 46 normal intrauterine pregnancies, TVS showed additional information in 36 patients (78.3% as compared to TAS, in detection of gestation sac, yolk sac, double bleb sign, or better visualization of embryonic anatomy. In the abnormal pregnancy (n=17, TVS provided more information in 11 cases (64.9%, which included detection of embryonic demise, yolk sac, double bleb sign, or subchorionic hemorrhage. Regarding ectopic gestations (n=7, TVS gave additional information in 5

  13. Evaluation of breast symptoms with mammography and ultrasonography

    Directory of Open Access Journals (Sweden)

    Emine Devolli Disha

    2011-12-01

    Full Text Available Introduction: Aim of the study was to discern which are more frequent symptoms presented in malign and benign masses diagnosed by mammography and ultrasonography.Methods: Our study group consisted of 546 female patients, with breast symptoms such as palpable lumps (40.8%, pain in the breast (26%, localized lumpiness or nodularity (13.7%, nipple retraction (11.2%, nipplebloody discharge (5.1% and redness and swelling of the breast (3.1%. All 546 patients were examined by ultrasonography and mammography. Biopsy was performed according to the findings of mammography and ultrasonography.Results: In breast cancer detection ultrasonography showed an efficiency of 79.4% compared to 55.0% for mammography in detecting breast lump, in the case of nipple retraction mammography showed an efficiency of 89.1% compared to 80.4% for ultrasound, while the lowest efficiency for mammography was in the cases with localized lumpiness or nodularity 17.1% compared to 45.7% for ultrasound. In detecting fibrocystic changes where the most common symptoms was pain, ultrasonography showed an efficiency of 99.3 % compared to 84.2 % for mammography.Conclusions: Our study confirmed that breast lumps are detectable in the majority of patients with breast cancer. The most frequent symptoms in patient with benign lesions were pain or localized discomfort. The diagnostic accuracy for carcinomas of the breast and for benign lesions according to symptoms was higher for ultrasound than for mammography.

  14. Ultrasonography - A diagnostic modality for oral and maxillofacial diseases

    Directory of Open Access Journals (Sweden)

    Priya Shirish Joshi

    2014-01-01

    Full Text Available Background: Many diseases present themselves in oral and maxillofacial regions and various modalities may be applied for their diagnosis, including intraoral and panoramic radiography, ultrasonography (USG, computer tomography, magnetic resonance imaging, and nuclear medicine methods such as positron emission tomography. Of these modalities, USG is easy to-use for the detection of non-invasive and soft tissue related diseases in oral and maxillofacial regions. USG plays an important role in analyzing normal and abnormal structures. In particular, in oral and maxillofacial regions, the USG may be clinically applied to evaluate lymph nodes, subcutaneous, and oral cavity-related diseases. Aims: The aim was to correlate the findings of USG and histopathology for the diagnosis of oral and maxillofacial pathology and to evaluate whether USG can be used as an adjunct in diagnosing oral and maxillofacial pathology. Materials and Methods: A total of 10 clinically diagnosed patients with intraoral cancerous growths, swellings in maxillary and neck region were included in this study. Incision biopsy was obtained for confirming provisional clinical diagnosis. The selected cases were advised USG. All patients were then posted either for hemi-glossectomy, hemi-mandibulectomy, and partial maxillectomy with or without radical neck dissection. Statistical Analysis: Student′s t-test and coefficient of correlation was used to statistically analyze significant relationship of both the methods. Result: In all 10 cases, USG correlated well with histopathology findings, it could also delineate tumor extent and measure tumor thickness. Conclusion: USG is an excellent method for the diagnosis of soft tissue lesions and can be used as an adjunct in diagnosing oral and maxillofacial pathology.

  15. Cholescintigraphy and ultrasonography in patients suspected of having acute cholecystitis

    DEFF Research Database (Denmark)

    Lauritsen, K B; Sommer, W; Hahn, L

    1988-01-01

    The diagnostic power of combined cholescintigraphy and ultrasonography was tested in 67 patients suspected of having acute cholecystitis; of these, 42 (63%) had acute cholecystitis. The predictive value of a positive scintigraphy (PVpos) was 95% and that of a negative (PVneg) was 91% (n = 67......). The PVpos and PVneg of ultrasonography were 89% and 75%, respectively (n = 54), and these values did not achieve statistical significance when compared with those for scintigraphy. Inconclusive tests were 10% and 11%, respectively, but in no patient were both scintigraphy and ultrasonography inconclusive...... that in patients suspected of having acute cholecystitis cholescintigraphy should be the first diagnostic procedure performed. If the scintigraphy is positive, additional ultrasonographic detection of gallstones makes the diagnosis almost certain. If one diagnostic modality is inconclusive, the other makes a fair...

  16. Ultrasonography and radiography of the canine postpartum uterus

    International Nuclear Information System (INIS)

    Pharr, J.W.; Post, K.

    1992-01-01

    A vulvovaginal discharge following parturition in a bitch is often a cause of concern to owners and clinicians, especially if whelping was complicated in any way. Ultrasonography could potentially distinguish between normal and abnormal postpartum uterine states because the uterine wall and luminal contents can be imaged in detail. Five normal bitches were examined to determine the normal ultrasonographic appearance of the postpartum uterus and the sensitivity of ultrasonography in detecting the involuting uterus, comparing this sensitivity with that of radiography. Ultrasonography was done at 1, 4, 8, 12, 18 and 24 days postpartum, radiography at 1, 4, 8, 12 and 18 days postpartum. By 12 days postpartum, the uterus could not be seen on radiographs, while at 24 days postpartum the uterus was still sonographically identifiable. The ultrasonographic characteristics of the involuting uterus are described

  17. The diagnostic value of ultrasonography in the gyneocological emergency

    International Nuclear Information System (INIS)

    Su Hui; Chen Fanghua; Peng Xiulan

    2006-01-01

    Objective: To evaluate the ultrasonography in the diagnosis and differential diagnosis of gynecologic emergency. Methods: 138 patients suffered from gynecologic emergency were examined with ultrasonography. The images were retrospectively reviewed and compared with pathologic or clinical results. Results: The total correct diagnostic rate was 89.1%. Among 138 cases of gynecologic emergency, there were 45 cases of ectopic pregnancy, 27 cases of ruptured corpus luteum, 24 cases of torsion of ovarian cyst, and 42 cases of acute pelvic inflammation. The correct diagnostic rates were 91.1%, 81.5%, 87.5%, 92.2%, respectively. Conclusion: The ultrasonography plays an important role in the diagnosis of gynecological emergency. When the US findings were not typical, the clinical history, symptoms and HCG level should be considered in order to avoid misdiagnosis. (authors)

  18. The usefulness of endoscopic ultrasonography in differentiation between benign and malignant gastric ulcer

    Directory of Open Access Journals (Sweden)

    Roganović Branka

    2016-01-01

    Full Text Available Background/Aim. Gastric ulcer may be benign or malignant. In terms of therapy and patient’s prognosis early detection of malignancy is very important. The aim of this study was to assess the usefulness of endoscopic ultrasound (EUS in differentiation between benign and malignant gastric ulcer. Methods. A prospective study included 20 consecutive adult patients with malignant gastric ulceration and 20 consecutive adult patients with benign gastric ulceration. All the patients underwent EUS. A total of 6 parameters were analyzed: ulcer width, ulcer depth, the thickness of the gastric wall along the edge of ulceration (T0, the thickness of the gastric wall 2 cm from the edge of ulceration (T2, loss of layering structure of the gastric wall, and the presence of regional lymph nodes. EUS criteria for malignancy and a point-score of malignancy were defined. The critical value of total point-score was also calculated showing the best reliability parameters. Results. There are 4 criteria for malignancy of gastric ulceration: T0 > 10 mm, T2 > 5 mm, EUS visualization of at least one lymph node, loss of layering structure of the gastric wall. Furthermore, T2 > 5 mm was the only EUS independent predictor of ulcer malignancy. The total point score of ≥ 4 was the cut-off pointscore value which gave the best reliability parameters in the assessment of malignant ulcers: sensitivity of 70%, specificity of 95%, positive predictive value of 93.3%, negative predictive value of 76% and accuracy of 82.5%. Conclusion. According to the results obtained in this study, we can conclude that EUS is usefull in differentiation between benign and malignant gastric ulcer.

  19. [Abdominal ultrasonography in patients with diabetes mellitus. Part 1: Liver].

    Science.gov (United States)

    Jenssen, C; Pietsch, C; Gottschalk, U; Barreiros, A P; Teufel, A; Cui, X W; Dietrich, C F

    2015-04-01

    In patients with diabetes mellitus, abdominal ultrasonography is the appropriate diagnostic technique to detect and to follow-up secondary and accompanying diseases of the liver, the kidneys, the pancreas, the gastrointestinal tract and of abdominal vessels. Moreover, pancreatic and hepatic diseases may be realized which are of etiological importance for diabetes mellitus. Based on a systematic survey of the published literature, this review in 3 parts will describe the value of abdominal ultrasonography in patients with diabetes mellitus. Part 1 deals with the diagnostic relevance and particular findings of ultrasonographic methods in hepatic manifestations and complications of diabetes mellitus. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Paediatric ultrasonography of the liver, hepatobiliary tract and pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Rijn, R.R. van, E-mail: r.r.vanrijn@amc.uva.nl [Department of Radiology, Emma Children' s Hospital – Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Nievelstein, R.A.J. [Department of Radiology, Wilhelmina Children' s Hospital – University Medical Center, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2014-09-15

    In the field of paediatric radiology ultrasonography (US) is the most versatile imaging tool available. Children in general, by virtue of their body composition, are excellent candidates for US exams in whom abdominal anatomy and pathology can be visualised in great detail. The fact that during the US study a clinical history can be obtained strongly adds to the value of the US exam. This does require investment in time and expertise and ideally a paediatric radiologist performing the exam. In this review the role of ultrasonography (US) of the liver, biliary tract and pancreas in children is discussed.

  1. Ultrasonography of hydronephrosis in the newborn: A practical review

    International Nuclear Information System (INIS)

    Choi, Young Hun; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One

    2016-01-01

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn

  2. Ultrasonography of hydronephrosis in the newborn: a practical review

    Science.gov (United States)

    2016-01-01

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn. PMID:27156562

  3. Ultrasonography of hydronephrosis in the newborn: A practical review

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Hun; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Children' s Hospital, Seoul (Korea, Republic of)

    2016-07-15

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn.

  4. Effect of provider experience on clinician-performed ultrasonography for hydronephrosis in patients with suspected renal colic.

    Science.gov (United States)

    Herbst, Meghan K; Rosenberg, Graeme; Daniels, Brock; Gross, Cary P; Singh, Dinesh; Molinaro, Annette M; Luty, Seth; Moore, Christopher L

    2014-09-01

    Hydronephrosis is readily visible on ultrasonography and is a strong predictor of ureteral stones, but ultrasonography is a user-dependent technology and the test characteristics of clinician-performed ultrasonography for hydronephrosis are incompletely characterized, as is the effect of ultrasound fellowship training on predictive accuracy. We seek to determine the test characteristics of ultrasonography for detecting hydronephrosis when performed by clinicians with a wide range of experience under conditions of direct patient care. This was a prospective study of patients presenting to an academic medical center emergency department with suspected renal colic. Before computed tomography (CT) results, an emergency clinician performed bedside ultrasonography, recording the presence and degree of hydronephrosis. CT data were abstracted from the dictated radiology report by an investigator blinded to the bedside ultrasonographic results. Test characteristics of bedside ultrasonography for hydronephrosis were calculated with the CT scan as the reference standard, with test characteristics compared by clinician experience stratified into 4 levels: attending physicians with emergency ultrasound fellowship training, attending physicians without emergency ultrasound fellowship training, ultrasound experienced non-attending physician clinicians (at least 2 weeks of ultrasound training), and ultrasound inexperienced non-attending physician clinicians (physician assistants, nurse practitioners, off-service rotators, and first-year emergency medicine residents with fewer than 2 weeks of ultrasound training). There were 670 interpretable bedside ultrasonographic tests performed by 144 unique clinicians, 80.9% of which were performed by clinicians directly involved in the care of the patient. On CT, 47.5% of all subjects had hydronephrosis and 47.0% had a ureteral stone. Among all clinicians, ultrasonography had a sensitivity of 72.6% (95% confidence interval [CI] 65.4% to 78

  5. COMPUTING

    CERN Multimedia

    M. Kasemann

    Overview In autumn the main focus was to process and handle CRAFT data and to perform the Summer08 MC production. The operational aspects were well covered by regular Computing Shifts, experts on duty and Computing Run Coordination. At the Computing Resource Board (CRB) in October a model to account for service work at Tier 2s was approved. The computing resources for 2009 were reviewed for presentation at the C-RRB. The quarterly resource monitoring is continuing. Facilities/Infrastructure operations Operations during CRAFT data taking ran fine. This proved to be a very valuable experience for T0 workflows and operations. The transfers of custodial data to most T1s went smoothly. A first round of reprocessing started at the Tier-1 centers end of November; it will take about two weeks. The Computing Shifts procedure was tested full scale during this period and proved to be very efficient: 30 Computing Shifts Persons (CSP) and 10 Computing Resources Coordinators (CRC). The shift program for the shut down w...

  6. Killian-Jamieson Diverticulum Mimicking a Thyroid Nodule on Ultrasonography: A Case Report

    International Nuclear Information System (INIS)

    Kim, Eun Soo; Lee, Kwan Seop; Yoon, Hoi Soo; Jeon, Eui Yong; Hwang, Hee Sung; Koh, Sung Hye; Kim, Min Jeong; Jang, Kyung Mi; Lee, Myung Jun; Lee, Yul

    2007-01-01

    Thyroid ultrasonography is widely used for diagnosis and cytologic evaluation of thyroid nodules. We encountered a case of Killian-Jamieson diverticulum, which was differentiated from a thyroid nodule using ultrasonography

  7. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction CMS distributed computing system performed well during the 2011 start-up. The events in 2011 have more pile-up and are more complex than last year; this results in longer reconstruction times and harder events to simulate. Significant increases in computing capacity were delivered in April for all computing tiers, and the utilisation and load is close to the planning predictions. All computing centre tiers performed their expected functionalities. Heavy-Ion Programme The CMS Heavy-Ion Programme had a very strong showing at the Quark Matter conference. A large number of analyses were shown. The dedicated heavy-ion reconstruction facility at the Vanderbilt Tier-2 is still involved in some commissioning activities, but is available for processing and analysis. Facilities and Infrastructure Operations Facility and Infrastructure operations have been active with operations and several important deployment tasks. Facilities participated in the testing and deployment of WMAgent and WorkQueue+Request...

  8. COMPUTING

    CERN Multimedia

    P. McBride

    The Computing Project is preparing for a busy year where the primary emphasis of the project moves towards steady operations. Following the very successful completion of Computing Software and Analysis challenge, CSA06, last fall, we have reorganized and established four groups in computing area: Commissioning, User Support, Facility/Infrastructure Operations and Data Operations. These groups work closely together with groups from the Offline Project in planning for data processing and operations. Monte Carlo production has continued since CSA06, with about 30M events produced each month to be used for HLT studies and physics validation. Monte Carlo production will continue throughout the year in the preparation of large samples for physics and detector studies ramping to 50 M events/month for CSA07. Commissioning of the full CMS computing system is a major goal for 2007. Site monitoring is an important commissioning component and work is ongoing to devise CMS specific tests to be included in Service Availa...

  9. COMPUTING

    CERN Multimedia

    M. Kasemann

    Overview During the past three months activities were focused on data operations, testing and re-enforcing shift and operational procedures for data production and transfer, MC production and on user support. Planning of the computing resources in view of the new LHC calendar in ongoing. Two new task forces were created for supporting the integration work: Site Commissioning, which develops tools helping distributed sites to monitor job and data workflows, and Analysis Support, collecting the user experience and feedback during analysis activities and developing tools to increase efficiency. The development plan for DMWM for 2009/2011 was developed at the beginning of the year, based on the requirements from the Physics, Computing and Offline groups (see Offline section). The Computing management meeting at FermiLab on February 19th and 20th was an excellent opportunity discussing the impact and for addressing issues and solutions to the main challenges facing CMS computing. The lack of manpower is particul...

  10. The role of B-mode ultrasonography in the musculoskeletal anatomical evaluation of the cervical region of the dog spine

    Directory of Open Access Journals (Sweden)

    Cibely G. Sarto

    2014-01-01

    Full Text Available This study characterized the normal musculoskeletal anatomy of the cervical segment of the spine of dogs by means of B-mode ultrasonography. The objective was to establish the role of B-mode ultrasonography for the anatomical evaluation of the cervical spine segment in dogs, by comparing the ultrasonographic findings with images by computed tomography and magnetic resonance imaging. The ultrasound examination, in transverse and median sagittal sections, allowed to identify a part of the epaxial cervical musculature, the bone surface of the cervical vertebrae and parts of the spinal cord through restricted areas with natural acoustic windows, such as between the atlanto-occipital joint, axis and atlas, and axis and the third cervical vertebra. The images, on transverse and sagittal planes, by low-field magnetic resonance imaging, were superior for the anatomical identification of the structures, due to higher contrast between the different tissues in this modality. Computed tomography showed superiority for bone detailing when compared with ultrasonography. As for magnetic resonance imaging, in addition to the muscles and cervical vertebrae, it is possible to identify the cerebrospinal fluid and differentiate between the nucleus pulposus and annulus fibrosus of the intervertebral discs. Although not the scope of this study, with knowledge of the ultrasonographic anatomy of this region, it is believed that some lesions can be identified, yet in a limited manner, when compared with the information obtained mainly with magnetic resonance imaging. The ultrasound examination presented lower morphology diagnostic value compared with the other modalities.

  11. Atlas-based knee osteophyte assessment with ultrasonography and radiography

    DEFF Research Database (Denmark)

    Koski, J M; Kamel, Ayadi; Waris, P

    2016-01-01

    OBJECTIVES: To investigate intra- and inter-reader agreement of ultrasonography (US) and conventional radiography (CR) for the evaluation of osteophyte presence and size within the tibiofemoral joint. In addition, to correlate these findings with arthroscopic degeneration of the articular cartila...

  12. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2012-01-01

    The wrist region is one of the most complex joints of the human body. It is prone to deformity and functional impairment in juvenile idiopathic arthritis (JIA), and is difficult to examine clinically. The aim of this study was to evaluate the role of ultrasonography (US) with Doppler in diagnosis...

  13. An unanticipated diagnosis with bedside ultrasonography in patients ...

    African Journals Online (AJOL)

    Although abdominal pain is a common presentation in emergency departments, rectus sheath hematoma (RSH) is among the rarest diagnosis. Here we present 2 cases of RSH likely caused by coughing due to upper respiratory tract infection. The two described cases were diagnosed by bedside ultrasonography and ...

  14. The accuracy rate of Alvarado score, ultrasonography, and ...

    African Journals Online (AJOL)

    Objective: In this study, we aim to compare the relationship between the Alvarado score, ultrasonography, and multislice computerized tomography (CT) findings used for the diagnosis of the patients who presented to our emergency unit with clinical features suggestive of acute appendicitis. Materials and Methods: ...

  15. Imaging in hematology. Part 1: Ultrasonography and conventional radiology

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    Applications of conventional ultrasonography techniques (B-mode or real time) in oncohematology are presented. The newer adaptations (in particular colour Doppler) provide incremental advantages that support their inclusion in the imaging techniques available to modern hematology. Conventional radiologic studies include chest and bone X-ray, gastrointestinal contrast examination and bipedal lymphangiography

  16. Impact of magnetic resonance urography and ultrasonography on ...

    African Journals Online (AJOL)

    Background: (1) To evaluate the diagnostic value of magnetic resonance urography (MRU) in comparison with ultrasonography (US) to determine the extent of upper urinary tract dilation and (2) to evaluate the impact of MRU on therapy management. Materials and Methods: From January 2005 to December 2010, ...

  17. In-utero diagnosis of Norrie disease by ultrasonography.

    Science.gov (United States)

    Redmond, R M; Vaughan, J I; Jay, M; Jay, B

    1993-03-01

    Obstetric ultrasonography of an obligate Norrie disease carrier revealed bilateral retinal detachments in a third trimester male fetus. Postnatal examination confirmed the diagnosis of Norrie disease. DNA linkage analysis with the markers L1.28 and MAO had been uninformative for this family. This report suggests that retinal detachment occurs late in the gestation of the affected fetus.

  18. COMPUTING

    CERN Multimedia

    I. Fisk

    2013-01-01

    Computing activity had ramped down after the completion of the reprocessing of the 2012 data and parked data, but is increasing with new simulation samples for analysis and upgrade studies. Much of the Computing effort is currently involved in activities to improve the computing system in preparation for 2015. Operations Office Since the beginning of 2013, the Computing Operations team successfully re-processed the 2012 data in record time, not only by using opportunistic resources like the San Diego Supercomputer Center which was accessible, to re-process the primary datasets HTMHT and MultiJet in Run2012D much earlier than planned. The Heavy-Ion data-taking period was successfully concluded in February collecting almost 500 T. Figure 3: Number of events per month (data) In LS1, our emphasis is to increase efficiency and flexibility of the infrastructure and operation. Computing Operations is working on separating disk and tape at the Tier-1 sites and the full implementation of the xrootd federation ...

  19. COMPUTING

    CERN Multimedia

    I. Fisk

    2010-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion An activity that is still in progress is computing for the heavy-ion program. The heavy-ion events are collected without zero suppression, so the event size is much large at roughly 11 MB per event of RAW. The central collisions are more complex and...

  20. COMPUTING

    CERN Multimedia

    M. Kasemann P. McBride Edited by M-C. Sawley with contributions from: P. Kreuzer D. Bonacorsi S. Belforte F. Wuerthwein L. Bauerdick K. Lassila-Perini M-C. Sawley

    Introduction More than seventy CMS collaborators attended the Computing and Offline Workshop in San Diego, California, April 20-24th to discuss the state of readiness of software and computing for collisions. Focus and priority were given to preparations for data taking and providing room for ample dialog between groups involved in Commissioning, Data Operations, Analysis and MC Production. Throughout the workshop, aspects of software, operating procedures and issues addressing all parts of the computing model were discussed. Plans for the CMS participation in STEP’09, the combined scale testing for all four experiments due in June 2009, were refined. The article in CMS Times by Frank Wuerthwein gave a good recap of the highly collaborative atmosphere of the workshop. Many thanks to UCSD and to the organizers for taking care of this workshop, which resulted in a long list of action items and was definitely a success. A considerable amount of effort and care is invested in the estimate of the comput...

  1. EUS-guided drainage of pancreatic fluid collections using a novel lumen-apposing metal stent on an electrocautery-enhanced delivery system : a large retrospective study (with video)

    NARCIS (Netherlands)

    Rinninella, Emanuele; Kunda, Rastislav; Dollhopf, Markus; Sanchez-Yague, Andres; Will, Uwe; Tarantino, Ilaria; Gornals Soler, Joan; Ullrich, Sebastian; Meining, Alexander; Esteban, Josè Miguel; Enz, Thomas; Vanbiervliet, Geoffroy; Vleggaar, FP; Attili, Fabia; Larghi, Alberto

    2015-01-01

    BACKGROUND AND AIMS: A lumen-apposing, self-expanding metal stent incorporated in an electrocautery-enhanced delivery system for EUS-guided drainage of pancreatic fluid collections (PFCs) recently has become available. The aim of this study was to analyze the safety and clinical effectiveness of

  2. Retrospective comparison of abdominal ultrasonography and radiography in the investigation of feline abdominal disease

    Science.gov (United States)

    Won, Wylen Wade; Sharma, Ajay; Wu, Wenbo

    2015-01-01

    Abdominal radiography and ultrasonography are commonly used as part of the initial diagnostic plan for cats with nonspecific signs of abdominal disease. This retrospective study compared the clinical usefulness of abdominal radiography and ultrasonography in 105 feline patients with signs of abdominal disease. The final diagnosis was determined more commonly with ultrasonography (59%) compared to radiography (25.7%). Ultrasonography was also able to provide additional clinically relevant information in 76% of cases, and changed or refined the diagnosis in 47% of cases. Based on these findings, ultrasonography may be sufficient as an initial diagnostic test for the investigation of feline abdominal disease. PMID:26483582

  3. Prevention of wrong absorption of pancreatic pseudocyst using guided transmural drainage under endoscopic ultrasonography%超声内镜引导经胃内引流术治疗胰腺假性囊肿误吸的预防

    Institute of Scientific and Technical Information of China (English)

    梁运啸; 郑琴芳; 覃柳; 农兵; 梁列新; 潘咏

    2017-01-01

    目的 探讨如何预防在超声内镜(EUS)引导下经胃内治疗胰腺假性囊肿引起的误吸.方法 对该院所做的EUS引导下经胃内引流胰腺假性囊肿的资料进行回顾性分析.结果 16例胰腺假性囊肿患者,经EUS引导胃内穿刺放置内支架引流成功16例,穿刺引流操作成功率为100.0%.囊肿完全吸收16例,治愈率100.0%.穿刺后囊液反流导致误吸2例,发生率为12.5%.3例患者通过内镜拔出引流支架,另外13例患者支架自行脱落排出.结论 头高脚低位、精细操作及食管套管可以防止EUS穿刺后胰腺假性囊肿囊液误吸入气管.%Objective To discuss how to preven wrong absorption of pancreatic pseudocyst using guided transmural drainage under endoscopic ultrasonography.Methods Retrospectively analyzed the clinical data of patients with pancreatic pseudocysts underwent operations of Endoscopic ultrasonography guided transmural drainage.Results 16 cases of pancreatic pseudocysts were finished with guided transmural drainage under endoscopic ultrasonography using needling to place bypass grafting with successful rate 100.0% of guided transmural drainage by needling. After needling, 2 cased happened regurgitation which led to wrongly absorbed, rate of occurrence is 12.5%. Generally, pancreatic pseudocysts of 16 cases disappeared completely with cure rate 100.0%. From above, stents were pulled out by endoscope in 3 cases while stents were removed voluntarily in another 13 cases.Conclusion Dorsal elevated position, detailed operation and esophageal annular tubes can effectively prevent wrong absorption of guided transmural drainage under endoscopic ultrasonography of pancreatic pseudocysts.

  4. COMPUTING

    CERN Multimedia

    P. McBride

    It has been a very active year for the computing project with strong contributions from members of the global community. The project has focused on site preparation and Monte Carlo production. The operations group has begun processing data from P5 as part of the global data commissioning. Improvements in transfer rates and site availability have been seen as computing sites across the globe prepare for large scale production and analysis as part of CSA07. Preparations for the upcoming Computing Software and Analysis Challenge CSA07 are progressing. Ian Fisk and Neil Geddes have been appointed as coordinators for the challenge. CSA07 will include production tests of the Tier-0 production system, reprocessing at the Tier-1 sites and Monte Carlo production at the Tier-2 sites. At the same time there will be a large analysis exercise at the Tier-2 centres. Pre-production simulation of the Monte Carlo events for the challenge is beginning. Scale tests of the Tier-0 will begin in mid-July and the challenge it...

  5. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction During the past six months, Computing participated in the STEP09 exercise, had a major involvement in the October exercise and has been working with CMS sites on improving open issues relevant for data taking. At the same time operations for MC production, real data reconstruction and re-reconstructions and data transfers at large scales were performed. STEP09 was successfully conducted in June as a joint exercise with ATLAS and the other experiments. It gave good indication about the readiness of the WLCG infrastructure with the two major LHC experiments stressing the reading, writing and processing of physics data. The October Exercise, in contrast, was conducted as an all-CMS exercise, where Physics, Computing and Offline worked on a common plan to exercise all steps to efficiently access and analyze data. As one of the major results, the CMS Tier-2s demonstrated to be fully capable for performing data analysis. In recent weeks, efforts were devoted to CMS Computing readiness. All th...

  6. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion The Tier 0 infrastructure was able to repack and promptly reconstruct heavy-ion collision data. Two copies were made of the data at CERN using a large CASTOR disk pool, and the core physics sample was replicated ...

  7. COMPUTING

    CERN Multimedia

    I. Fisk

    2012-01-01

    Introduction Computing continued with a high level of activity over the winter in preparation for conferences and the start of the 2012 run. 2012 brings new challenges with a new energy, more complex events, and the need to make the best use of the available time before the Long Shutdown. We expect to be resource constrained on all tiers of the computing system in 2012 and are working to ensure the high-priority goals of CMS are not impacted. Heavy ions After a successful 2011 heavy-ion run, the programme is moving to analysis. During the run, the CAF resources were well used for prompt analysis. Since then in 2012 on average 200 job slots have been used continuously at Vanderbilt for analysis workflows. Operations Office As of 2012, the Computing Project emphasis has moved from commissioning to operation of the various systems. This is reflected in the new organisation structure where the Facilities and Data Operations tasks have been merged into a common Operations Office, which now covers everything ...

  8. COMPUTING

    CERN Multimedia

    M. Kasemann

    CCRC’08 challenges and CSA08 During the February campaign of the Common Computing readiness challenges (CCRC’08), the CMS computing team had achieved very good results. The link between the detector site and the Tier0 was tested by gradually increasing the number of parallel transfer streams well beyond the target. Tests covered the global robustness at the Tier0, processing a massive number of very large files and with a high writing speed to tapes.  Other tests covered the links between the different Tiers of the distributed infrastructure and the pre-staging and reprocessing capacity of the Tier1’s: response time, data transfer rate and success rate for Tape to Buffer staging of files kept exclusively on Tape were measured. In all cases, coordination with the sites was efficient and no serious problem was found. These successful preparations prepared the ground for the second phase of the CCRC’08 campaign, in May. The Computing Software and Analysis challen...

  9. COMPUTING

    CERN Multimedia

    I. Fisk

    2010-01-01

    Introduction The first data taking period of November produced a first scientific paper, and this is a very satisfactory step for Computing. It also gave the invaluable opportunity to learn and debrief from this first, intense period, and make the necessary adaptations. The alarm procedures between different groups (DAQ, Physics, T0 processing, Alignment/calibration, T1 and T2 communications) have been reinforced. A major effort has also been invested into remodeling and optimizing operator tasks in all activities in Computing, in parallel with the recruitment of new Cat A operators. The teams are being completed and by mid year the new tasks will have been assigned. CRB (Computing Resource Board) The Board met twice since last CMS week. In December it reviewed the experience of the November data-taking period and could measure the positive improvements made for the site readiness. It also reviewed the policy under which Tier-2 are associated with Physics Groups. Such associations are decided twice per ye...

  10. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction More than seventy CMS collaborators attended the Computing and Offline Workshop in San Diego, California, April 20-24th to discuss the state of readiness of software and computing for collisions. Focus and priority were given to preparations for data taking and providing room for ample dialog between groups involved in Commissioning, Data Operations, Analysis and MC Production. Throughout the workshop, aspects of software, operating procedures and issues addressing all parts of the computing model were discussed. Plans for the CMS participation in STEP’09, the combined scale testing for all four experiments due in June 2009, were refined. The article in CMS Times by Frank Wuerthwein gave a good recap of the highly collaborative atmosphere of the workshop. Many thanks to UCSD and to the organizers for taking care of this workshop, which resulted in a long list of action items and was definitely a success. A considerable amount of effort and care is invested in the estimate of the co...

  11. COMPUTING

    CERN Multimedia

    2010-01-01

    Introduction Just two months after the “LHC First Physics” event of 30th March, the analysis of the O(200) million 7 TeV collision events in CMS accumulated during the first 60 days is well under way. The consistency of the CMS computing model has been confirmed during these first weeks of data taking. This model is based on a hierarchy of use-cases deployed between the different tiers and, in particular, the distribution of RECO data to T1s, who then serve data on request to T2s, along a topology known as “fat tree”. Indeed, during this period this model was further extended by almost full “mesh” commissioning, meaning that RECO data were shipped to T2s whenever possible, enabling additional physics analyses compared with the “fat tree” model. Computing activities at the CMS Analysis Facility (CAF) have been marked by a good time response for a load almost evenly shared between ALCA (Alignment and Calibration tasks - highest p...

  12. COMPUTING

    CERN Multimedia

    Contributions from I. Fisk

    2012-01-01

    Introduction The start of the 2012 run has been busy for Computing. We have reconstructed, archived, and served a larger sample of new data than in 2011, and we are in the process of producing an even larger new sample of simulations at 8 TeV. The running conditions and system performance are largely what was anticipated in the plan, thanks to the hard work and preparation of many people. Heavy ions Heavy Ions has been actively analysing data and preparing for conferences.  Operations Office Figure 6: Transfers from all sites in the last 90 days For ICHEP and the Upgrade efforts, we needed to produce and process record amounts of MC samples while supporting the very successful data-taking. This was a large burden, especially on the team members. Nevertheless the last three months were very successful and the total output was phenomenal, thanks to our dedicated site admins who keep the sites operational and the computing project members who spend countless hours nursing the...

  13. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction A large fraction of the effort was focused during the last period into the preparation and monitoring of the February tests of Common VO Computing Readiness Challenge 08. CCRC08 is being run by the WLCG collaboration in two phases, between the centres and all experiments. The February test is dedicated to functionality tests, while the May challenge will consist of running at all centres and with full workflows. For this first period, a number of functionality checks of the computing power, data repositories and archives as well as network links are planned. This will help assess the reliability of the systems under a variety of loads, and identifying possible bottlenecks. Many tests are scheduled together with other VOs, allowing the full scale stress test. The data rates (writing, accessing and transfer¬ring) are being checked under a variety of loads and operating conditions, as well as the reliability and transfer rates of the links between Tier-0 and Tier-1s. In addition, the capa...

  14. COMPUTING

    CERN Multimedia

    Matthias Kasemann

    Overview The main focus during the summer was to handle data coming from the detector and to perform Monte Carlo production. The lessons learned during the CCRC and CSA08 challenges in May were addressed by dedicated PADA campaigns lead by the Integration team. Big improvements were achieved in the stability and reliability of the CMS Tier1 and Tier2 centres by regular and systematic follow-up of faults and errors with the help of the Savannah bug tracking system. In preparation for data taking the roles of a Computing Run Coordinator and regular computing shifts monitoring the services and infrastructure as well as interfacing to the data operations tasks are being defined. The shift plan until the end of 2008 is being put together. User support worked on documentation and organized several training sessions. The ECoM task force delivered the report on “Use Cases for Start-up of pp Data-Taking” with recommendations and a set of tests to be performed for trigger rates much higher than the ...

  15. COMPUTING

    CERN Multimedia

    P. MacBride

    The Computing Software and Analysis Challenge CSA07 has been the main focus of the Computing Project for the past few months. Activities began over the summer with the preparation of the Monte Carlo data sets for the challenge and tests of the new production system at the Tier-0 at CERN. The pre-challenge Monte Carlo production was done in several steps: physics generation, detector simulation, digitization, conversion to RAW format and the samples were run through the High Level Trigger (HLT). The data was then merged into three "Soups": Chowder (ALPGEN), Stew (Filtered Pythia) and Gumbo (Pythia). The challenge officially started when the first Chowder events were reconstructed on the Tier-0 on October 3rd. The data operations teams were very busy during the the challenge period. The MC production teams continued with signal production and processing while the Tier-0 and Tier-1 teams worked on splitting the Soups into Primary Data Sets (PDS), reconstruction and skimming. The storage sys...

  16. COMPUTING

    CERN Multimedia

    I. Fisk

    2013-01-01

    Computing operation has been lower as the Run 1 samples are completing and smaller samples for upgrades and preparations are ramping up. Much of the computing activity is focusing on preparations for Run 2 and improvements in data access and flexibility of using resources. Operations Office Data processing was slow in the second half of 2013 with only the legacy re-reconstruction pass of 2011 data being processed at the sites.   Figure 1: MC production and processing was more in demand with a peak of over 750 Million GEN-SIM events in a single month.   Figure 2: The transfer system worked reliably and efficiently and transferred on average close to 520 TB per week with peaks at close to 1.2 PB.   Figure 3: The volume of data moved between CMS sites in the last six months   The tape utilisation was a focus for the operation teams with frequent deletion campaigns from deprecated 7 TeV MC GEN-SIM samples to INVALID datasets, which could be cleaned up...

  17. COMPUTING

    CERN Multimedia

    I. Fisk

    2012-01-01

      Introduction Computing activity has been running at a sustained, high rate as we collect data at high luminosity, process simulation, and begin to process the parked data. The system is functional, though a number of improvements are planned during LS1. Many of the changes will impact users, we hope only in positive ways. We are trying to improve the distributed analysis tools as well as the ability to access more data samples more transparently.  Operations Office Figure 2: Number of events per month, for 2012 Since the June CMS Week, Computing Operations teams successfully completed data re-reconstruction passes and finished the CMSSW_53X MC campaign with over three billion events available in AOD format. Recorded data was successfully processed in parallel, exceeding 1.2 billion raw physics events per month for the first time in October 2012 due to the increase in data-parking rate. In parallel, large efforts were dedicated to WMAgent development and integrati...

  18. Ultrasonography and cholescintigraphy in the diagnostics of biliary tree

    International Nuclear Information System (INIS)

    Iskrenova, Zh.; Minchev, D.

    1997-01-01

    The purpose is to determine whether a reversed sequence of bile flow (i.e. small bowel followed by gallbladder) could serve as an indicator of chronic cholecystitis. 43 hepatobiliary scans were reviewed retrospectively with attention to the relative order of gallbladder and small bowel appearance during the first hour. Usually radioactive bile flows initially into the gallbladder followed by passage into the small bowel. The scintigraphic findings were correlated with results from gallbladder histopathology and gallbladder ultrasonography in 11 patients. The specificity of a reversed sequence for chronic cholecystitis was 82% using ultrasonography and 100% for histopathology. The visualization of gallbladder after the small bowel appears in patients referred for possible biliary tract disease predicts chronic cholecystitis (author)

  19. Role of ultrasonography in the ocular and the orbital diseases

    International Nuclear Information System (INIS)

    Kim, S. R.; Kim, K. S.; Lee, Y. C.; Park, S. S.

    1984-01-01

    With conventional methods including orbital arteriography, orbital venography, penumoobitography and positive contrast orbitography, imaging of eyeball and orbit is not only difficult, invasive or expensive but also nonspecific in result. Ultrasonography provides safe, specific and reliable way to obtain image of eyeball and orbit. Fifty six ultrasonograms of 50 patients which were referred under the impression of various ophthalmic diseases were analyzed. 1. Sixteen cases were normal. 2. Ocular diseases were 26 cases and extraocular orbital diseases were 8 cases. 3. Among the ocular diseases, 9 foreign body cases, 6 retinal detachment cases, 5 vitreous hemorrhage 4. Among the extraocular orbital diseases, 6 pseudotumor cases, 1 pseudolymphoma, 1 eyelid cyst case were diagnosed. 5. Ultrasonic findings were specific enough to differentiated from diseases and well corresponded with clinical and pathological diagnosis. 6. It can be concluded that ultrasonography is one of the most reliable imaging method in ocular and extraocular orbital diseases

  20. Ultrasonography of Midline Scalp Masses : A Preliminary Report

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyo Kyeong; Lee, Ho Kyu; Choi, Choong Gon; Kim, Kyeong Sook; Jung, Seung Mun; Suh, Dae Chul [Asan Medical Center University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    We report our ultrasonographic experiences in the evaluation of small midline scalp masses. Ultrasonography was performed in four patients with midline scalp mass less than 3cm and its connecting tract into the cranialcavity. Ultrasonographic findings were correlated with pathologic results. There were three cephaloceles and one cystic lymph angioma. Two encephalomenin-goceles, located in occipital region, were mixed cystic and solid lesions and one atretic meningocele in parietal region was a solid lesion. Ultrasonogram of all three cases showed calvarial defect and connecting tract into the cranial cavity. On the contrary, a cystic lymph angioma in occipital region was a purely cystic mass without an associated calvarial defect. We suppose that ultrasonography could be a useful screening tool in the evaluation of midline scalp masses

  1. Transrectal ultrasonography of anorectal disease: advantages and disadvantages

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Ju [Dept. of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2015-01-15

    Transrectal ultrasonography (TRUS) has been widely accepted as a popular imaging modality for Epub ahead of print evaluating the lower rectum, anal sphincters, and pelvic floor in patients with various anorectal diseases. It provides excellent visualization of the layers of the rectal wall and of the anatomy of the anal canal. TRUS is an accurate tool for the staging of primary rectal cancer, especially for early stages. Although magnetic resonance imaging is a modality complementary to TRUS with advantages for evaluating the mesorectum, external sphincter, and deep pelvic inflammation, three-dimensional ultrasonography improves the detection and characterization of perianal fistulas and therefore plays a crucial role in optimal treatment planning. The operator should be familiar with the anatomy of the rectum and pelvic structures relevant to the preoperative evaluation of rectal cancer and other anal canal diseases, and should have technical proficiency in the use of TRUS combined with an awareness of its limitations compared to magnetic resonance imaging.

  2. Henoch-Schonlein purpura: ultrasonography of scrotal and penile involvement

    Directory of Open Access Journals (Sweden)

    Youngsik Lim

    2015-04-01

    Full Text Available Testicular or scrotal involvement has been reported in children with Henoch-Schonlein purpura (HSP, but there are very few reports on penile involvement. We report the initial and follow-up ultrasonographic findings of scrotal and penile involvement of HSP in a 5-year-old boy. On ultrasonography, scrotal soft tissue thickening and epididymal swelling with increased vascularity were noted, and on the penis, a focal mass-like lesion appeared on the dorsal surface of the distal penis, having a hypoechoic mass-like appearance without visible vascular flow on a Doppler study. After 2 days of treatment, follow-up ultrasonography showed normal scrotum and penis with a resolved soft tissue mass-like lesion. Therefore, we think that HSP ultrasonographic findings involving the scrotum and penis might help to diagnose scrotal and penile involvement in a case of HSP and to avoid unnecessary medication and/or surgical procedures.

  3. Diagnostic ultrasonography in cattle with abdominal fat necrosis.

    Science.gov (United States)

    Tharwat, Mohamed; Buczinski, Sébastien

    2012-01-01

    This study describes the ultrasonographic findings in 14 cows with abdominal fat necrosis. Ultrasonography of the abdomen revealed the presence of heterogeneous hyperechoic masses and hyperechoic omentum with localized masses floating in a hypoechoic peritoneal fluid. A hyperechogenic rim was imaged around both kidneys. The intestines were coated with hyperechoic capsules and the intestinal lumens were constricted. Ultrasonographic examination of the pancreatic parenchyma showed an overall increased echogenicity which was homogenously distributed in 3 cases. A diagnosis of abdominal fat necrosis was made with ultrasound-guided biopsy of the echogenic masses, and thereafter at postmortem examination. Results from this study demonstrate the efficacy of ultrasonography as an imaging modality for antemortem diagnosis of abdominal lipomatosis in cattle. To the authors' knowledge, this study is the first that illustrates ultrasonographic findings in cattle affected with abdominal lipomatosis.

  4. Interobserver Variation of the Renal Length Measurement on Ultrasonography

    International Nuclear Information System (INIS)

    Jeong, Yoong Ki; Chung, Hye Weon; Kim, Tae Sung; Ryoo, Jae Wook; Kim, Tae Kyoung; Kim, Seung Hyup

    1995-01-01

    We assessed interobserver variation in the measurement of the renal length on ultrasonography. Ultrasonographic examinations were performed in randomly selected 50 patients. The maximallenhths of both kidneys were measured with calipers during the scanning from frozen images by three observers in a blinded fashion. There was a relatively constant tendency of an observer to measure a renal length either longer or shorter than the other observer(Kendall coefficient>0.05). Average interobserver variations were 0.51 cm (±0.42 cm) in right kidney and 0.53 cm (±0.41 cm) in left kidney and were within 1 cm in 91% right and 89% of left kidney. Interobserver variation about 1cm should be considered in the measurement of the renal length on ultrasonography

  5. On use of ultrasonography in obstetrics and gynecology

    International Nuclear Information System (INIS)

    Woo, Kwang Suk; Lee, Yong Woo

    1984-01-01

    Ultrasonography is playing an very important in diagnosis of normal pregnancy and the other diseases in the fields of obstetrics and gynecology. It is mainly used B-mode and Real time linear scan for pregnancy such as fetal movement during its early stage, fetal position, placenta location and biparietal diameter during its middle stage, and amniotic fluid and placenta previa during its late stage, as well as tumor accompanying pregnancy. Ultrasonography has been extensively used in the fields of obstetrics and gynecology for obtaining detailed images of soft tissues without hazard to the fetus and pregnant woman. In view of the need for its professionalism of high degree of skill, this treatise will introduce clinical instances and images obtained in the sonography room of the Seoul National University Hospital

  6. Reliable and Valid Assessment of Point-of-care Ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt

    2015-01-01

    physicians' OSAUS scores with diagnostic accuracy. RESULTS: The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores......OBJECTIVE: To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. BACKGROUND: POC US is increasingly used by clinicians and is an essential part of the management of acute surgical...... conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. METHODS: Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different...

  7. Is ultrasonography essential before surgery in eyes with advanced cataracts?

    Directory of Open Access Journals (Sweden)

    Salman Amjad

    2006-01-01

    Full Text Available Background: Ultrasonography is an important tool for evaluating the posterior segment in eyes with opaque media. Aim: To study the incidence of posterior segment pathology in eyes with advanced cataract and to see whether certain features could be used as predictors for an abnormal posterior segment on ultrasound. Setting: Tertiary care hospital in South India. Methods and Materials: In this prospective study conducted over a 6-month period, all eyes with dense cataracts precluding visualization of fundus underwent assessment with ultrasound. Presence of certain patient and ocular "risk" factors believed to be associated with a higher incidence of abnormal posterior segment on ultrasound were looked for and the odds ratio (OR for posterior segment pathology in these eyes was calculated. Results: Of the 418 eyes assessed, 36 eyes (8.6% had evidence of posterior segment pathology on ultrasound. Retinal detachment (17 eyes; 4.1% was the most frequent abnormality detected. Among patient features, diabetes mellitus (OR= 4.9, P=0.003 and age below 50 years (OR= 15.4, P=0.001 were associated with a high incidence of abnormal ultrasound scans. In ocular features, posterior synechiae (OR= 20.2, P=0.000, iris coloboma (OR= 34.6, P=0.000, inaccurate projection of rays (OR= 15.1, P=0.002, elevated intraocular pressure (OR= 15.1, P=0.004, and keratic precipitates (OR= 22.4, P=0.004 were associated with high incidence of posterior segment pathology. Only four eyes (1.5% without these features had abnormal posterior segment on ultrasonography. Conclusions: Certain patient and ocular features are indicative of a high risk for posterior segment pathology and such patients should be evaluated by ultrasonography prior to cataract surgery. In the absence of these risk factors, the likelihood of detecting abnormalities on preoperative ultrasonography in eyes with advanced cataracts is miniscule.

  8. Comparison of ultrasonography and radiography in diagnosis of rib fractures

    OpenAIRE

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-01-01

    Purpose: Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. Methods: In this cross-s...

  9. Pictorial essay: B-scan ultrasonography in ocular abnormalities

    International Nuclear Information System (INIS)

    Aironi, VD; Gandage, SG

    2009-01-01

    B-scan ultrasonography (USG) is a simple, noninvasive tool for diagnosing lesions of the posterior segment of the eyeball. Common conditions such as cataract, vitreous degeneration, retinal detachment, ocular trauma, choroidal melanoma, and retinoblastoma can be accurately evaluated with this modality. B-scan USG is cost-effective, which is an important consideration in the rural setting. In addition, it is noninvasive and easily available and the results are reproducible

  10. Ultrasonography of the omasum in 30 Saanen goats

    Directory of Open Access Journals (Sweden)

    Jacquat Désirée

    2011-02-01

    Full Text Available Abstract Background Primary diseases of the omasum are uncommon in goats, although the omasum may be involved in various gastrointestinal disorders. Examination of the caprine omasum via ultrasonography requires a good understanding of the normal appearance of the organ. However, in contrast to cattle, there is a lack of reference information on this topic in goats. Thus, the goal of the present study was to describe the results of ultrasonography of the omasum in 30 healthy Saanen goats. Results Ultrasonography was carried out in standing, non-sedated goats using a 5.0 MHz linear transducer. The location and size of the omasum, thickness of the omasal wall and visualisation of the abomasal laminae, contents and contractions were assessed. The omasum was visible from the 9th intercostal space (ICS in all the goats, and from the 8th and 10th ICSs in 29 and 24 goats, respectively. The omasum was seen medial to the liver, but only the omasal wall closest to the transducer was visible. The dorsal omasal limit formed a dorsally convex curve running from cranioventral to caudodorsal and was furthest from the dorsal midline in the 6th ICS. The ventral omasal limit formed a ventrally convex curve. The size of the omasum was largest (10.2 ± 3.1 cm in the 9th ICS and decreased cranially and caudally from this position. Active omasal motility was recorded in 20 goats with 0.3 to 2.0 contractions per minute. Conclusions The findings of this study provide reference ranges for the interpretation of the location and size of the omasum in goats with suspected omasal abnormalities. Ultrasonography is an ideal diagnostic tool for evaluation of the omasum, which is not accessible to conventional examination techniques, such as inspection, palpation, percussion and auscultation.

  11. Urinary tract infection in children: Role of ultrasonography

    International Nuclear Information System (INIS)

    Lee, Hye Won; Lee, Sun Wha; Ko, Young Tae; Lim, Joo Won

    1994-01-01

    To evaluate diagnostic usefulness of ultrasonography(US) in pediatric patient with urinary tract infection. Fifty-five children with urinary tract infection underwent renal ultrasonography and voiding cystourethrography(VCUG). The imaging findings were analyzed retrospectively. Renal sonograms were normal in 34 of 55 children(62%). Five of 34 patients with normal sonogram had vesicoureteral reflux of grade I and III on VCUG. Renal sonograms were abnormal in 21 of 55 children(38%). Sonographic findings included hydronephrosis, hyperechoic kidney, nephromegaly, altrophic kidney, renal abscess, and duplex ureter. Eleven of 21 patient with abnormal sonogram had vesicoureteral reflux of grade I to IV on VCUG. Ultrasonography is an useful and reliable initial screening examination in the investigation of children with UTI. Unfortunately US is neither sufficiently sensitive nor specific for detecting VUR. VCUG provides confirmative and valuable information about vesicoureteral reflux, and VCUG should be considered as a next modality for UTI. The combined use of sonography and VCUG provides more valuable information in urinary tract infection

  12. Ultrasonography of the equine shoulder: technique and normal appearance.

    Science.gov (United States)

    Tnibar, M A; Auer, J A; Bakkali, S

    1999-01-01

    This study was intended to document normal ultrasonographic appearance of the equine shoulder and anatomic landmarks useful in clinical imaging. Both forelimbs of five equine cadavers and both forelimbs of six live adult horses were used. To facilitate understanding of the images, a zoning system assigned to the biceps brachii and to the infraspinatus tendon was developed. Ultrasonography was performed with a real-time B-mode semiportable sector scanner using 7.5- and 5-MHz transducers. On one cadaver limb, magnetic resonance imaging (MRI) was performed using a system at 1.5 Tesla, T1-weighted spin-echo sequence. Ultrasonography images were compared to frozen specimens and MRI images to correlate the ultrasonographic findings to the gross anatomy of the shoulder. Ultrasonography allowed easy evaluation of the biceps brachii and the infraspinatus tendon and their bursae, the supraspinatus muscle and tendons, the superficial muscles of the shoulder, and the underlying humerus and scapula. Only the lateral and, partially, the caudal aspects of the humeral head could be visualized with ultrasound. Ultrasonographic appearance, orientation, and anatomic relationships of these structures are described. Ultrasonographic findings correlated well with MRI images and with gross anatomy in the cadavers' limbs.

  13. Evaluation of arterial embolization in treating hyperthyroidism by colour ultrasonography

    International Nuclear Information System (INIS)

    Sun Xiuying; Yang Jijin; Chen Ningning; Gu Limin; Wang Ying; Chen Jianquan

    2003-01-01

    Objective: To assess the effect of arterial embolization in treating hyperthyroidism by colour ultrasonography. Methods: Forty two cases of hyperthyroidism were treated with thyroid-arteries embolization. A few days before and 1, 3, 6 months after embolization, the echograms of thyroids were observed including the volumes of thyroids and the internal diameters of thyroid-arteries were measured with colour ultrasonography respectively. The Vs, Vd, Vm, PI, RI were measured with the Doppler and the quantities of blood flow were calculated. The relationships of changes for all these parameters and T 3 , T 4 and TSH were analysed. Results: Before artery embolization all thyroids were enlarged with diffusely homogenous or heterogenous low-echoes and nodules in some patients accompanied by widening of the thyroid arteries and their branches full of blood supply. The volume of thyroids decreased after artery embolization. 1-3 months later the echo of thyroids enhanced and got coarse with decrease of the thyroid vasculature and narrowing of vessel calibers except a few star- or stop-like blood streams were sometimes seen within the thyroids and no blood flow signals found in some cases. 3-6 months after embolization, the echo of thyroids decreased gradually or unevenly distributed. All the parameters of blood flow before and after the treatment showed statistically significant differences (P < 0.05). Conclusions: Embolization of thyroid arteries is a relatively new and effective technique in treating hyperthyroidism. Colour Doppler ultrasonography plays an important role for correct diagnosis and prognostication

  14. Peritoneal inclusion cysts: Changes on follow-up ultrasonography

    International Nuclear Information System (INIS)

    Kim, Jung Sik; Lee, Jin Hee; Lee, Hee Jung; Lee, Sung Moon; Woo, Seong Ku

    2003-01-01

    To evaluate the volume change of peritoneal inclusion cysts on the follow-up ultrasonography (US). From March 1995 to May 1999, thirty seven women with ultrasonographically diagnosed peritoneal inclusion cysts were included in this study. Six patients underwent surgery for several reasons. Follow-up ultrasonography was performed 70-456 days (mean=191 days) after initial US examination in 12 of the remaining 31 patient with no further treatment. US was performed with a 3.5 or 4 MHz transabdominal probe in all 18 patients who underwent either surgery or follow-up US, and additional tranvaginal US examination using a 5-7 MHz probe in 15 of 18 patients. The volume change of the cysts was recorded for each US examination. Three cysts (25%) (volume=170 cm 3 , 61 cm 3 , and 38 cm 3 , respectively) were completely resolved on the follow-up US while the other nine cysts showed a decreased volume in seven patients (58%) and increased volume in two patients (17%). Spontaneous regression of peritoneal inclusion cysts is more common than it is believed to be, and ultrasonography may be a useful follow-up examination for peritoneal inclusion cysts.

  15. Ultrasonography in the evaluation of tongue and mouth pathology

    International Nuclear Information System (INIS)

    Lee, Chan Wha; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Lee, Jong Tae; Hong, Won Pyo; Park, Hyung Sik

    1991-01-01

    The evaluation of the tongue and mouth floor using the CT scan can be limited due to dental artifacts. Because the therapeutic plan depends on the nature and the cancer staging of lesions, it is essential to obtain accurate evaluation of lesions. In this study are explored the of Ultrasonography for the evaluation of tongue and mouth floor pathology. We have obtained ultrasonograms in 20 patients who had benign and malignant lesions in the tongue and mouth floor. Comparative analysis was made on 15 patients who underwent both CT and ultrasonography. We used the bimanual compression technique and the phonation technique during real-time scanning. Out of 15 cases, six had tongue cancer, and seven of them had cancer of the mouth floor. The other cases included a ranula, a dermoid cyst, a Ludwig's angina, and abscess of salivary gland, and one care with stones of the submandibular gland. All the benign and malignant masses appeared hypoechoic. Even though the lesions of tongue and mouth floor could not be evaluated by CT scan due to dental artifacts and extremely small size in 5 cases, ultrasonogram using the bimanual compression technique demonstrated good localization of the lesion, and also was greatly helpful in visualizing the invasion of the surrounding structures. Ultrasonography of the tongue and mouth floor proved to be superior to the CT scan not only in delineating the size and extent of the primary lesion, but also in visualizing invasion of surrounding structures

  16. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction The Computing Team successfully completed the storage, initial processing, and distribution for analysis of proton-proton data in 2011. There are still a variety of activities ongoing to support winter conference activities and preparations for 2012. Heavy ions The heavy-ion run for 2011 started in early November and has already demonstrated good machine performance and success of some of the more advanced workflows planned for 2011. Data collection will continue until early December. Facilities and Infrastructure Operations Operational and deployment support for WMAgent and WorkQueue+Request Manager components, routinely used in production by Data Operations, are provided. The GlideInWMS and components installation are now deployed at CERN, which is added to the GlideInWMS factory placed in the US. There has been new operational collaboration between the CERN team and the UCSD GlideIn factory operators, covering each others time zones by monitoring/debugging pilot jobs sent from the facto...

  17. Local ablation therapy with contrast-enhanced ultrasonography for hepatocellular carcinoma: a practical review

    Directory of Open Access Journals (Sweden)

    Tae Kyoung Kim

    2015-10-01

    Full Text Available A successful program for local ablation therapy for hepatocellular carcinoma (HCC requires extensive imaging support for diagnosis and localization of HCC, imaging guidance for the ablation procedures, and post-treatment monitoring. Contrast-enhanced ultrasonography (CEUS has several advantages over computed tomography/magnetic resonance imaging (CT/MRI, including real-time imaging capability, sensitive detection of arterial-phase hypervascularity and washout, no renal excretion, no ionizing radiation, repeatability, excellent patient compliance, and relatively low cost. CEUS is useful for image guidance for isoechoic lesions. While contrast-enhanced CT/MRI is the standard method for the diagnosis of HCC and post-ablation monitoring, CEUS is useful when CT/MRI findings are indeterminate or CT/MRI is contraindicated. This article provides a practical review of the role of CEUS in imaging algorithms for pre- and post-ablation therapy for HCC.

  18. The current status of the three-dimensional ultrasonography in gyneaecology

    Energy Technology Data Exchange (ETDEWEB)

    Ong, Chiou Li [Dept. of Diagnostic and Interventional Imaging, KK Women' s and Children' s Hospital, Singapore (Singapore)

    2016-01-15

    Ultrasonography (US) is the most recent cross-sectional imaging modality to acquire three-dimensional (3D) capabilities. The reconstruction of volumetric US data for multiplanar display took a significantly longer time to develop in comparison with computed tomography and magnetic resonance imaging. The current equipment for 3D-US is capable of producing high-resolution images in three different planes, including real-time surface-rendered images. The use of 3D-US in gynaecology was accelerated through the development of the endovaginal volume transducer, which allows the automated acquisition of volumetric US data. Although initially considered an adjunct to two-dimensional US, 3D-US is now the imaging modality of choice for the assessment of Müllerian duct anomalies and the location of intrauterine devices.

  19. Nanoparticles as image enhancing agents for ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Liu Jun [Biomedical Engineering Department, Ohio State University, 270 Bevis Hall, 1080 Carmack Rd, Columbus, OH 43210 (United States); Levine, Andrea L [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States); Mattoon, John S [Department of Veterinary Clinical Sciences, Ohio State University, 1151 Veterinary Hospital, 601 Vernon Tharp St., Columbus, OH 43210 (United States); Yamaguchi, Mamoru [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States); Lee, Robert J [Division of Pharmaceutics, College of Pharmacy, NCI Comprehensive Cancer Center, and NSF Nanoscale Science and Engineering Center, Ohio State University, 500 West 12th Avenue, Columbus, OH 43210 (United States); Pan Xueliang [Department of Statistics, Ohio State University, 1958 Neil Avenue, Columbus, OH 43210 (United States); Rosol, Thomas J [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States)

    2006-05-07

    Nanoparticles have drawn great attention as targeted imaging and/or therapeutic agents. The small size of the nanoparticles allows them to target cells that are beyond capillary vasculature, such as cancer cells. We investigated the effect of solid nanoparticles for enhancing ultrasonic grey scale images in tissue phantoms and mouse livers in vivo. Silica nanospheres (100 nm) were dispersed in agarose at 1-2.5% mass concentration and imaged by a high-resolution ultrasound imaging system (transducer centre frequency: 30 MHz). Polystyrene particles of different sizes (500-3000 nm) and concentrations (0.13-0.75% mass) were similarly dispersed in agarose and imaged. Mice were injected intravenously with nanoparticle suspensions in saline. B-mode images of the livers were acquired at different time points after particle injection. An automated computer program was used to quantify the grey scale changes. Ultrasonic reflections were observed from nanoparticle suspensions in agarose gels. The image brightness, i.e., mean grey scale level, increased with particle size and concentration. The mean grey scale of mouse livers also increased following particle administration. These results indicated that it is feasible to use solid nanoparticles as contrast enhancing agents for ultrasonic imagin000.

  20. MRI versus ultrasonography to assess meniscal abnormalities in acute knees.

    Science.gov (United States)

    Cook, James L; Cook, Cristi R; Stannard, James P; Vaughn, Gavin; Wilson, Nichole; Roller, Brandon L; Stoker, Aaron M; Jayabalan, Prakash; Hdeib, Moses; Kuroki, Keiichi

    2014-08-01

    While magnetic resonance imaging (MRI) is often considered the "gold standard" diagnostic imaging modality for detection of meniscal abnormalities, it is associated with misdiagnosis in as high as 47% of cases, is costly, and is not readily available to a large number of patients. Ultrasonographic examination of the knee has been reported to be an effective diagnostic tool for this purpose with the potential to overcome many of the shortcomings of MRI. The purpose of this study is to determine the clinical usefulness of ultrasonography for diagnosis of meniscal pathology in patients with acute knee pain and compare its diagnostic accuracy to MRI in a clinical setting. With Institutional Review Board approval, patients (n = 71) with acute knee pain were prospectively enrolled with informed consent. Preoperative MRI (1.5 T) was performed on each affected knee using the hospital's standard equipment and protocols and read by faculty radiologists trained in musculoskeletal MRI. Ultrasonographic assessments of each affected knee were performed by one of two faculty members trained in musculoskeletal ultrasonography using a 10 to 14 MHz linear transducer. Arthroscopic evaluation of affected knees was performed by one of three faculty orthopedic surgeons to assess and record all joint pathology, which served as the reference standard for determining presence, type, and severity of meniscal pathology. All evaluators for each diagnostic modality were blinded to all other data. Data were collected and compared by a separate investigator to determine sensitivity (Sn), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), correct classification rate (CCR), likelihood ratios (LR[+] and LR[-]), and odds ratios. Preoperative ultrasonographic assessment of meniscal pathology was associated with Sn = 91.2%, Sp = 84.2%, PPV = 94.5%, NPV = 76.2%, CCR = 89.5%, LR(+) = 5.78, and LR(-) = 0.10. Preoperative MRI assessment of

  1. COMPUTING

    CERN Multimedia

    M. Kasemann

    CMS relies on a well functioning, distributed computing infrastructure. The Site Availability Monitoring (SAM) and the Job Robot submission have been very instrumental for site commissioning in order to increase availability of more sites such that they are available to participate in CSA07 and are ready to be used for analysis. The commissioning process has been further developed, including "lessons learned" documentation via the CMS twiki. Recently the visualization, presentation and summarizing of SAM tests for sites has been redesigned, it is now developed by the central ARDA project of WLCG. Work to test the new gLite Workload Management System was performed; a 4 times increase in throughput with respect to LCG Resource Broker is observed. CMS has designed and launched a new-generation traffic load generator called "LoadTest" to commission and to keep exercised all data transfer routes in the CMS PhE-DEx topology. Since mid-February, a transfer volume of about 12 P...

  2. SENSITIVITY OF ENDOSCOPIC ULTRASOUND, MULTIDETECTOR COMPUTER TOMOGRAPHY AND MAGNETIC RESONANCE CHOLANGIOPANCREATOGRAPHY IN THE DIAGNOSIS OF PANCREAS DIVISUM: A TERTIARY CENTER EXPERIENCE

    Science.gov (United States)

    Kushnir, Vladimir M.; Wani, Sachin B.; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris; Mullady, Daniel; Jonnalagadda, Sreenivasa S.; Early, Dayna S.; Edmundowicz, Steven A.; Azar, Riad R.

    2014-01-01

    OBJECTIVES There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: 1. Evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP) and multi-detector computed tomography (MDCT) for pancreas divisum. 2. Assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. METHODS For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography (ERP) who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent ERP and cross-sectional imaging. RESULTS The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) [ppancreas divisum; IOA was moderate (қ=0.43). CONCLUSIONS EUS is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum. PMID:23211370

  3. Ultrasonography evaluation during the weaning process: the heart, the diaphragm, the pleura and the lung.

    Science.gov (United States)

    Mayo, P; Volpicelli, G; Lerolle, N; Schreiber, A; Doelken, P; Vieillard-Baron, A

    2016-07-01

    On a regular basis, the intensivist encounters the patient who is difficult to wean from mechanical ventilatory support. The causes for failure to wean from mechanical ventilatory support are often multifactorial and involve a complex interplay between cardiac and pulmonary dysfunction. A potential application of point of care ultrasonography relates to its utility in the process of weaning the patient from mechanical ventilatory support. This article reviews some applications of ultrasonography that may be relevant to the process of weaning from mechanical ventilatory support. The authors have divided these applications of ultrasonography into four separate categories: the assessment of cardiac, diaphragmatic, and lung function; and the identification of pleural effusion; which can all be evaluated with ultrasonography during a dynamic process in which the intensivist is uniquely positioned to use ultrasonography at the point of care. Ultrasonography may have useful application during the weaning process from mechanical ventilatory support.

  4. The role of contrast-enhanced ultrasonography in image-guided liver ablations

    International Nuclear Information System (INIS)

    Pescatori, Lorenzo Carlo; Sconfienza, Luca Maria; Mauri, Giovanni

    2016-01-01

    We read with great interest the paper by Kim et al. entitled “Local ablation therapy with contrast enhanced ultrasonography for hepatocellular carcinoma: a practical review,” recently published in Ultrasonography. We think that contrast-enhanced ultrasonography (CEUS), together with the development of reliable navigation systems, is likely to represent one of the most important advances in image-guided ablations in recent years. Thus, we offer some considerations on the topic

  5. Prenatal diagnosis of Beckwith-Wiedemann syndrome by two- and three-dimensional ultrasonography

    Directory of Open Access Journals (Sweden)

    Edward Araujo Junior

    2013-12-01

    Full Text Available Beckwith-Wiedemann syndrome is a genetic syndrome characterized by macroglossia, omphalocele, fetal gigantism and neonatal hypoglycemia. The authors report a case of Beckwith-Wiedemann syndrome diagnosed in a 32-year-old primigravida in whom two-dimensional ultrasonography revealed the presence of abdominal wall cyst, macroglossia and polycystic kidneys. Three-dimensional ultrasonography in rendering mode was of great importance to confirm the previous two-dimensional ultrasonography findings.

  6. Evaluation of abdominal palpation, radiography and ultrasonography for pregenancy diagnosis in bitches

    International Nuclear Information System (INIS)

    Arunmozhi, N.; Naidu, K.V.; Sreenu, M.; Rao, A.S.

    2005-01-01

    Abdominal palpation, radiography and ultrasonography were compared for pregnancy diagnosis in bitches. The earliest correct diagnosis of pregnancy was made by 22 and 21 days with abdominal palpation and ultrasonography respectively, while radiography led to more accurate diagnosis in last trimester of pregnancy. All the methods revealed 100 per cent accuracy in last trimester where as ultrasonography gave constant results from day 21 up to termination of pregnancy followed by abdominal palpation

  7. Comparison of the results of abdominal ultrasonography and exploratory laparotomy in the dog and cat.

    Science.gov (United States)

    Pastore, Gina E; Lamb, Christopher R; Lipscomb, Victoria

    2007-01-01

    Results of preoperative ultrasonography and exploratory laparotomy were reviewed retrospectively in a series of 100 small animals to assess the agreement between ultrasonographic and surgical findings and to identify abdominal lesions likely to be missed by ultrasonography. Good agreement occurred between ultrasound reports and surgical reports in 64% of the animals, which supported the use of ultrasonography in potential surgical candidates. A major discrepancy was observed between the ultrasound report and surgical findings in 25% of the animals. Of the various types of pathology encountered in the study, gastrointestinal ulceration or perforation was the most likely lesion to be missed by ultrasonography.

  8. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young [Dept. of Radiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  9. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Directory of Open Access Journals (Sweden)

    Ji Young Hwang

    2017-04-01

    Full Text Available Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  10. Echo intensity obtained from ultrasonography images reflecting muscle strength in elderly men

    Directory of Open Access Journals (Sweden)

    Watanabe Y

    2013-07-01

    Full Text Available Yuya Watanabe,1 Yosuke Yamada,1,2 Yoshihiro Fukumoto,3 Tatsuro Ishihara,4 Keiichi Yokoyama,1 Tsukasa Yoshida,1 Motoko Miyake,1 Emi Yamagata,5 Misaka Kimura1 1Laboratory of Sports and Health Science, Kyoto Prefectural University of Medicine, Kyoto, Japan; 2Research Fellow, Japan Society for the Promotion of Science, Tokyo, Japan; 3Faculty of Rehabilitation, Kobe Gakuin University, Kobe, Japan; 4Faculty of Health and Sports Science, Doshisha University, Kyoto, Japan; 5Laboratory of Gerontological Nursing, Kyoto Prefectural University of Medicine, Kyoto, Japan Background: It is well known that loss of muscle mass (quantitative change is a major change that occurs with aging. Qualitative changes in skeletal muscle, such as increased intramuscular fat, also occur as one ages. Enhanced echo intensity (EI on ultrasonography images of skeletal muscle is believed to reflect muscle quality. Recent studies evaluating the quality of skeletal muscle using computer-aided gray scale analysis showed that EI is associated with muscle strength independently of age or muscle size in middle-aged and elderly women. The aim of the present study was to investigate whether muscle quality based on EI is associated with muscle strength independently of muscle size for elderly men. Methods: A total of 184 elderly men (65–91 years living independently in Kyoto, Japan, participated in this study. The EI, muscle thickness (MT, and subcutaneous fat thickness (FT of the anterior compartment of the right thigh were determined by assessing ultrasonography images. The maximum isometric torque of knee extension at a knee angle of 90° was measured. Results: The EI showed a significant negative correlation with muscle strength (r = -0.333, P < 0.001. Multivariate regression analysis revealed that the MT and EI of the knee extensor muscle were independently associated with maximum isometric knee extension strength. Even when partial correlation analysis was performed with age

  11. Les "Questions et réponses sur les évangiles" d'Eusèbe de Césarée: étude et édition du résumé grec

    OpenAIRE

    Zamagni, Claudio; Junod, Eric; Le Boulluec, Alain

    2005-01-01

    Cette thèse propose la première édition critique de l’une des traditions les plus importantes des Questions et réponses sur les évangiles d’Eusèbe de Césarée, dont l’original est perdu. Il s’agit de l’édition du manuscrit contenant l’anthologie grecque du manuscrit Vaticanus Pal. Gr. 220. Cette anthologie est composée presque intégralement d’une suite d’extraits du texte original, non résumés, dont l’auteur n’est pas Eusèbe et dont la date ne peut pas être reportée avant le V-VIème siècle. Ce...

  12. Ultrasonography survey and thyroid cancer in the Fukushima Prefecture

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, Peter; Kaiser, Jan Christian; Ulanovsky, Alexander [Helmholtz Zentrum Muenchen-German Research Center for Environmental Health, Department of Radiation Sciences, Institute of Radiation Protection, Neuherberg (Germany)

    2014-05-15

    Thyroid cancer is one of the major health concerns after the accident in the Fukushima Dai-ichi nuclear power station (NPS). Currently, ultrasonography surveys are being performed for persons residing in the Fukushima Prefecture at the time of the accident with an age of up to 18 years. Here, the expected thyroid cancer prevalence in the Fukushima Prefecture is assessed based on an ultrasonography survey of Ukrainians, who were exposed at an age of up to 18 years to {sup 131}I released during the Chernobyl NPS accident, and on differences in equipment and study protocol in the two surveys. Radiation risk of thyroid cancer incidence among survivors of the atomic bombings of Hiroshima and Nagasaki and preliminary estimates of thyroid dose due to the Fukushima accident were used for the prediction of baseline and radiation-related thyroid cancer risks. We estimate a prevalence of thyroid cancer of 0.027 % (95 % CI 0.010 %; 0.050 %) for the first screening campaign in the Fukushima Prefecture. Compared with the incidence rate in Japan in 2007, the ultrasonography survey is predicted to increase baseline thyroid cancer incidence by a factor of 7.4 (95 % CI 0.95; 17.3). Under the condition of continued screening, thyroid cancer during the first fifty years after the accident is predicted to be detected for about 2 % of the screened population. The prediction of radiation-related thyroid cancer in the most exposed fraction (a few ten thousand persons) of the screened population of the Fukushima Prefecture has a large uncertainty with the best estimates of the average risk of 0.1-0.3 %, depending on average dose. (orig.)

  13. [Technique of abdominal ultrasonography in newborn foals and normal findings].

    Science.gov (United States)

    Behn, C; Bostedt, H

    2000-09-01

    Under field conditions, the diagnosis of foal's diseases relies almost exclusively on the physical examination. As the signs of illness in the equine neonate are frequently vage and non-localizing, the diagnosis of diseases may be problematic. This often causes misinterpretations and leads to ineffective prophylaxis and treatment. The purpose of this study was to evaluate the usefulness of diagnostic ultrasonography of the foal's abdomen under field conditions to provide an optimized technique and to describe the normal findings. Diagnostic ultrasonography of the abdomen was performed after obtaining clinical history and passing the physical examination of 25 foals without signs of abdominal problems. The foals were scanned in a stable box, being restrained by three persons in semi-lateral recumbency. Usually, sedation was not necessary. The ventral abdominal wall was clipped, a generous amount of ultrasound coupling gel was applied and massaged on the skin surface. The ultrasonographic examination was carried out using a portable sector scanner ("Microimager 2000", Ausonics) with 5.0 and 7.5-MHz transducers or a combined 5.0 and 7.5-MHz transrectal linear-array scanner ("450 Enhanced", Pie Medical). Employing the 5.0-MHz sector scanner first, the abdomen was explored from caudal to cranial in left and right semi-lateral recumbency. The 7.5-MHz scanner was used to attain higher resolution of certain structures. The sector scanner turned out to be suitable under field conditions and adequate to examine the abdominal organs. The transrectal linear-array scanner also provided the most important informations, although it was difficult to maintain a good contact area of the scan head. By ultrasonography it was possible to identify the urinary bladder, kidneys, spleen, liver and part of the gastrointestinal tract. Thus, application of ultrasound could successfully be performed on newborn foals under field conditions.

  14. Stomach: ultrasonography evaluation and post mortem inspection in adult horses

    Directory of Open Access Journals (Sweden)

    Cristiano Chaves Pessoa da Veiga

    2014-06-01

    Full Text Available ABSTRACT. Veiga C.C.P., Cascon C.M., Souza B.G., Braga L.S.M., Souza V.C., Ferreira A.M.R. & Leite J.S. [Stomach: ultrasonography evaluation and post mortem inspection in adult horses.] Avaliação ultrassonográfica e anatomopatológica macroscópica do estômago de equinos destinados ao abate comercial. Revista Brasileira de Medicina Veterinária, 36(2:125-130, 2014. Instituto de Veterinária, Universidade Federal Rural do Rio de Janeiro, BR 465, km 7, Seropédica, 23890-000, RJ, Brasil. E-mail: radiovet@ufrrj.br The equine gastric ulcer syndrome (EGUS includes all symptomatic or asymptomatic cases of erosions, ulcers, gastritis, gastric emptying disorders, duodenitis, duodenal ulcers and complications of these disorders. Occupies a prominent place in the equine clinic where you can go for the death of the animal. Ultrasonography of the stomach is indicated when the animals showed clinical signs of gastric disease. The aim of this study was to describe the sonographic evaluation and macroscopic pathological findings of the stomach of adult horses intended for commercial slaughter. To this 39 intended for commercial slaughter horses were evaluated. Sonographic evaluation before slaughter transabdominal via the left side of abdomen for evaluation of the stomach was performed. After the slaughter of these animals their stomachs were collected, evaluated and photographed. The study concluded that ultrasonography identified the stomach in all animals evaluated, but did not allow a careful evaluation of the entire length of the viscera, especially the aglandular region and pleated border. All animals evaluated had injury to the gastric mucosa in different degrees. In animals evaluated, the stomach region was most affected by injuries glandular region, although the most severe lesions have been found in the ruffled border adjacent to aglandular region.

  15. High-resolution ultrasonography in assessing temporomandibular joint disc position.

    Science.gov (United States)

    Talmaceanu, Daniel; Lenghel, Lavinia Manuela; Bolog, Nicolae; Popa Stanila, Roxana; Buduru, Smaranda; Leucuta, Daniel Corneliu; Rotar, Horatiu; Baciut, Mihaela; Baciut, Grigore

    2018-02-04

    The purpose of this study was to determine the diagnostic value of high-resolution ultrasonography (US) in temporomandibular joint (TMJ) disc displacements. A number of 74 patients (148 TMJs) with signs and symptoms of TMJ disorders, according to the Research Diagnostic Criteria for Temporomandibular Disorders, were included in this study. All patients received US and magnetic resonance imaging (MRI) of both TMJs 1 to 5 days after the clinical examination. MRI examinations were performed using 1.5 T MRI equipment (Siemens Avanto, Siemens, Erlangen). Ultrasonographic examination was performed on a Hitachi EUB 8500 (Hitachi Medical Corp., Tokyo, Japan) scanner with L 54 M6.5-13 MHz linear transducer. MRI depicted 68 (45.95%) normal joints, 47 (31.76%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 34 (22.97%) with degenerative changes. US detected 78 (52.7%) normal joints, 37 (25%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 21 (14.19%) with degenerative changes. Compared to MRI, US showed a sensitivity of 93.1%, specificity of 87.88%, accuracy of 90.32%, a positive predictive value of 87.1% and a negative predictive value of 93.55% for overall diagnosis of disc displacement. The Youden index was 0.81. Based on our results, high-resolution ultrasonography showed high sensitivity, specificity and accuracy in the diagnosis of TMJ disc displacement. It could be a valuable imaging technique in assessing TMJ disc position. The diagnostic value of high-resolution ultrasonography depends strictly on the examiner's skills and on the equipment used.

  16. Diagnostic accuracy of the ultrasonography in complicated pregnancy

    International Nuclear Information System (INIS)

    Cha, Kyung Soo; Kim, Kun Sang; Park, Soo Soung

    1983-01-01

    Ultrasonography is an invaluable diagnostic method in Obstetrics. It provides safe, speedy and repeatable way to obtain image of normal and abnormal pregnancy. The ultrasonograms of 167 patients with suspicion of complicated pregnancy were analyzed. The results were as follows. 1. 86 patients showed normal ultrasonogram(50.9%). 100% in intrauterine fetal death and gross fetal anomaly, 100% in abnormal fetal position and number, 95% in pregnancy with pelvic mass, 83% in ectopic pregnancy, 81% in abortion, 78% in molar pregnancy, 74% in plancenta previa. 3. Ultrasonic diagnosis of abrupto placenta was difficult. 4. Diagnostic accuracy was 80% in bicornuate uterus and double vagina

  17. Transthoracic ultrasonography for the immunocompromised patient. A pilot project that introduces transthoracic ultrasonography for the follow-up of hematological patients in Romania.

    Science.gov (United States)

    Frinc, Ioana; Ilies, Petru; Zaharie, Florin; Dima, Delia; Tanase, Alina; Petrov, Ljubomir; Irimie, Alexandru; Berce, Cristian; Lisencu, Cosmin; Berindan-Neagoe, Ioana; Tomuleasa, Ciprian; Bojan, Anca

    2017-06-01

    In the past decade, there has been significant progress in clinical hematology with the discovery of targeted molecules and thus the achievement of both hematologic and molecular responses. Nevertheless, chemotherapy remains the treatment of choice for many types of hematological malignancies. Aggressive chemotherapy leads to immunosuppression, accompanied by a high rate of infections and an increased rate of treatment-related mortality. Invasive fungal infections as well as more common bacterial and viral infections are frequent in immunocompromised patients as they are difficult to diagnose and treat. Pleuropulmonary infections in immunocompromised patients are diagnosed using clinical examination, imaging and laboratory tests. Many laboratory tests are run for several days before a final result is given and are expensive. Computer tomography is a reliable technique, but it is encumbered by high irradiation and high cost, and can assess lesions larger than 1 cm. Transthoracic ultrasound is a modern method, used in the diagnostic algorithm of pleuropulmonary pathology. It allows the diagnosis of small lesions, can be performed at the patients' bedside, with acceptable costs and no irradiation. A fast, informed and accurate medical decision is essential for a favorable outcome in immunosuppressed patients with an adjacent infection. In the current case series we present the implementation of a new protocol for the follow-up of immunocompromised patients using transthoracic ultrasonography, of great potential use in the clinic.

  18. Transthoracic ultrasonography for the immunocompromised patient. A pilot project that introduces transthoracic ultrasonography for the follow-up of hematological patients in Romania

    Directory of Open Access Journals (Sweden)

    Frinc Ioana

    2017-06-01

    Full Text Available In the past decade, there has been significant progress in clinical hematology with the discovery of targeted molecules and thus the achievement of both hematologic and molecular responses. Nevertheless, chemotherapy remains the treatment of choice for many types of hematological malignancies. Aggressive chemotherapy leads to immunosuppression, accompanied by a high rate of infections and an increased rate of treatment-related mortality. Invasive fungal infections as well as more common bacterial and viral infections are frequent in immunocompromised patients as they are difficult to diagnose and treat. Pleuropulmonary infections in immunocompromised patients are diagnosed using clinical examination, imaging and laboratory tests. Many laboratory tests are run for several days before a final result is given and are expensive. Computer tomography is a reliable technique, but it is encumbered by high irradiation and high cost, and can assess lesions larger than 1 cm. Transthoracic ultrasound is a modern method, used in the diagnostic algorithm of pleuropulmonary pathology. It allows the diagnosis of small lesions, can be performed at the patients’ bedside, with acceptable costs and no irradiation. A fast, informed and accurate medical decision is essential for a favorable outcome in immunosuppressed patients with an adjacent infection. In the current case series we present the implementation of a new protocol for the follow-up of immunocompromised patients using transthoracic ultrasonography, of great potential use in the clinic.

  19. Quadriceps Function and Knee Joint Ultrasonography after ACL Reconstruction.

    Science.gov (United States)

    Pamukoff, Derek N; Montgomery, Melissa M; Moffit, Tyler J; Vakula, Michael N

    2018-02-01

    Individuals with anterior cruciate ligament reconstruction (ACLR) are at greater risk for knee osteoarthritis, partially because of chronic quadriceps dysfunction. Articular cartilage is commonly assessed using magnetic resonance imaging and radiography, but these methods are expensive and lack portability. Ultrasound imaging may provide a cost-effective and portable alternative for imaging the femoral cartilage. The purpose of this study was to compare ultrasonography of the femoral cartilage between the injured and uninjured limbs of individuals with unilateral ACLR, and to examine the association between quadriceps function and ultrasonographic measures of femoral cartilage. Bilateral femoral cartilage thickness and quadriceps function were assessed in 44 individuals with unilateral ACLR. Quadriceps function was assessed using peak isometric strength, and early (RTD100) and late (RTD200) rate of torque development. Cartilage thickness at the medial femoral condyle (P accounting for time since ACLR, quadriceps peak isometric strength was associated with cartilage thickness at the medial femoral condyle (r = 0.35, P = 0.02) and femoral cartilage cross-sectional area (r = 0.28, P = 0.04). RTD100 and RTD200 were not associated with femoral cartilage thickness or cross-sectional area. Individuals with ACLR have thinner cartilage in their injured limb compared with uninjured limb, and cartilage thickness is associated with quadriceps function. These results indicate that ultrasonography may be useful for monitoring cartilage health and osteoarthritis progression after ACLR.

  20. Three-dimensional ultrasonography in the diagnosis of deep endometriosis.

    Science.gov (United States)

    Guerriero, Stefano; Saba, Luca; Ajossa, Silvia; Peddes, Cristina; Angiolucci, Marco; Perniciano, Maura; Melis, Gian Benedetto; Alcázar, Juan Luis

    2014-06-01

    In the use of 'tenderness-guided' transvaginal ultrasound, is the diagnostic accuracy of three-dimensional (3D) ultrasonography better than two-dimensional (2D) ultrasonography in the identification of deep endometriosis? Three-dimensional ultrasonography has a significantly higher diagnostic accuracy in the diagnosis of posterior locations of deep endometriosis without intestinal involvement, such as the uterosacral ligaments, vaginal and rectovaginal endometriosis. The only previous study of the diagnosis of posterior compartment endometriosis reported an poor sensitivity of 3D ultrasonography for uterosacral and sigmoid colon involvement. This diagnostic test study included 202 patients scheduled for surgery because of clinical suspicion of deep pelvic endometriosis and was carried out between January 2009 and September 2012. Modified transvaginal ultrasonography was performed on all of the women by a single examiner. Two locations of deep endometriosis were considered: intestinal involvement and other posterior lesions (including vaginal location, rectovaginal septum and uterosacral ligaments). Once the 2D ultrasonography had been performed, the 3D acquisition was performed and the obtained volume was stored. To avoid the risk of recall bias, the same operator evaluated the 3D volumes 6 months after the last examination using virtual navigation to provide a presumptive diagnosis of the presence and localization of deep endometriosis. In addition, to evaluate the reproducibility of 3D, two operators with different levels of expertise performed a retrospective review of 3D volumes from a random sample of 35 patients, twice, 1 week apart to also assess intraobserver agreement. The diagnostic performance of both tests was expressed as area under the receiver-operating characteristics curve (AUC), sensitivity, specificity, positive and negative predictive values, positive (LR+) and negative (LR-) likelihood ratios, with their respective 95% confidence interval (CI

  1. Ultrasonography for neuraxial blocks: a review of the evidence.

    Science.gov (United States)

    Elgueta, Maria F; Duong, Silvia; Finlayson, Roderick J; Tran, De Q

    2017-05-01

    This narrative review summarizes the evidence derived from randomized controlled trials (RCTs) pertaining to the use of adjunctive ultrasonography (US) for neuraxial blocks. The literature search was conducted using the MEDLINE, EMBASE and PUBMED databases. For the MEDLINE and EMBASE searches, the MESH terms "ultrasonography" and key word "ultrasound" were queried; using the operator "and", they were combined with the MESH terms "neuraxial block," "epidural anesthesia," "epidural analgesia," "spinal anesthesia," "spinal analgesia," "intrathecal anesthesia," "intrathecal analgesia," "caudal anesthesia," and "caudal analgesia." For the PUBMED search, the search terms "ultrasound neuraxial," "ultrasound intrathecal," "ultrasound epidural" (limited to clinical trials), "ultrasound spinal" (limited to clinical trials), and "ultrasound caudal" (limited to clinical trials) were queried. Seventeen RCTs were retained for analysis. Compared to conventional palpation of landmarks, US assistance (i.e., preprocedural scanning) results in fewer needle passes/insertions and skin punctures for neuraxial blocks in obstetrical and surgical patients. These benefits seem most pronounced when expert operators carry out the sonographic exams and for patients displaying difficult spinal anatomy. Preliminary findings also suggest that US provides similar pain relief and functional improvement to fluoroscopy for epidural/caudal steroid injection in patients afflicted with chronic spinal pain. Although one trial demonstrated shorter needling time with US guidance (i.e., real-time scanning of needle advancement) compared to US assistance, these findings require further validation. Published reports of RCTs provide evidence to formulate limited recommendations regarding the use of adjunctive US for neuraxial blocks. Further well-designed RCTs are warranted.

  2. Intraoperative ultrasonography of liver, bile ducts and pancreas

    Directory of Open Access Journals (Sweden)

    Luciana Mendes de Oliveira Cerri

    Full Text Available The use of intraoperative ultrasonography (IOUS to evaluate liver, bile ducts and pancreatic disease, as compared to the results of preoperative ultrasonography and CT, is discussed. Forty-two patients who underwent abdominal surgery for suspected hepatobiliary and/or pancreatic disease were studied. The intraoperative study was carried out with a portable apparatus (Aloka 500, Japan, using 5.0 MHz and 7.5 MHz linear sterile transducers. The main indications for IOUS were the search for and/or evaluation of primary hepatic masses,hepatic abscesses or metastases, obstructive jaundice, or neuroendocrine tumors. In 15 cases (38.5 percent from the hepatobiliary group and in 7 cases (58.3 percent from the pancreatic group, a difference between preoperative and intraoperative findings was observed. The main difference was observed in relation to the number and size of hepatic and pancreatic lesions. The relationship between the lesions and the vascular structures was evaluated through IOUS. The method was also used to guide surgical procedures such as biopsies, the alcoholization of nodules, and the drainage of abscesses. IOUS plays an important role in detecting small hepatic and pancreatic nodules, in the assessment of anatomical relationships between the lesions and the vascular structures, and in the performance of interventionist procedures.

  3. Validation of equations for pleural effusion volume estimation by ultrasonography.

    Science.gov (United States)

    Hassan, Maged; Rizk, Rana; Essam, Hatem; Abouelnour, Ahmed

    2017-12-01

    To validate the accuracy of previously published equations that estimate pleural effusion volume using ultrasonography. Only equations using simple measurements were tested. Three measurements were taken at the posterior axillary line for each case with effusion: lateral height of effusion ( H ), distance between collapsed lung and chest wall ( C ) and distance between lung and diaphragm ( D ). Cases whose effusion was aspirated to dryness were included and drained volume was recorded. Intra-class correlation coefficient (ICC) was used to determine the predictive accuracy of five equations against the actual volume of aspirated effusion. 46 cases with effusion were included. The most accurate equation in predicting effusion volume was ( H  +  D ) × 70 (ICC 0.83). The simplest and yet accurate equation was H  × 100 (ICC 0.79). Pleural effusion height measured by ultrasonography gives a reasonable estimate of effusion volume. Incorporating distance between lung base and diaphragm into estimation improves accuracy from 79% with the first method to 83% with the latter.

  4. The detection of prostatic carcinoma. 4- or 7-MHz transrectal ultrasonography?

    NARCIS (Netherlands)

    Vleeming, R.; Noordzij, J. W.; de Reijke, T. M.; Kurth, K. H.

    1993-01-01

    In this prospective study a comparison of 4-versus 7-MHz transrectal ultrasonography for the detection of prostatic carcinoma is reported. A total of 150 prostates were biopsied due to suspicion of malignancy arising at either digital rectal examination, 4- and/or 7-MHz transrectal ultrasonography,

  5. [A Multimedia Tutorial to Train Ultrasonography of the Thyroid for Medical Students].

    Science.gov (United States)

    Ritter, Julia; Wolfram, Maximilian; Schuler, Stefan; Guntinas-Lichius, Orlando

    2017-11-01

    Physicians in education often have poor experience in practice and assessment of ultrasonography on entering their profession, due to a deficiency of training offers during their study of medicine. Hence, a multimedia device for stepwise learning and training ultrasonography of the thyroid was developed. A software for a portable ultrasonography system was used to design a multimedia device for ultrasonography of the thyroid. It allows the user to illustrate texts and pictorial material simultaneously with ultrasound examination in order to compare own findings with examples from a database. The device was evaluated by 8 medical students and compared to a tutor-guided training. A structured, stepwise manual for ultrasonography of the thyroid with a large content of examples in different sectional images was designed for simultaneous reconstruction with the ultrasonography device. The informative content of the device and the replicability of the examination procedure were evaluated positively. Assessment respecting clarity, eligibility for users without experience and learning success was varying. The tutorial to learn and train ultrasonography of the thyroid is an instrument for self-learning and improving practical education in ultrasonography in medical education. In the next version, the manual for the examination will be structured in greater detail. © Georg Thieme Verlag KG Stuttgart · New York.

  6. A prospective comparison of transvaginal ultrasonography and diagnostic hysteroscopy in the evaluation of patients with abnormal uterine bleeding: clinical implications

    NARCIS (Netherlands)

    Emanuel, M. H.; Verdel, M. J.; Wamsteker, K.; Lammes, F. B.

    1995-01-01

    We determined the diagnostic value of transvaginal ultrasonography for endometrial and intrauterine abnormalities in patients with abnormal uterine bleeding. Between June 1, 1992, and June 1, 1993, 279 consecutive patients underwent transvaginal ultrasonography. Findings were compared with the final

  7. Muscle-tendon-related abnormalities detected by ultrasonography are common in symptomatic hip dysplasia

    DEFF Research Database (Denmark)

    Jacobsen, Julie Sandell; Bolvig, Lars; Hölmich, Per

    2018-01-01

    INTRODUCTION: Hip dysplasia is characterized by reduced acetabular coverage of the femoral head leading to an increased mechanical load on the hip joint and the acting hip muscles. Potentially, the muscles and tendons functioning close to the hip joint may present with overuse......-related ultrasonography findings. The primary aim was to report the prevalence of muscle-tendon-related abnormalities detected by ultrasonography in 100 patients with symptomatic hip dysplasia. The secondary aim was to investigate correlations between muscle-tendon-related abnormalities detected by ultrasonography......-tendon-related abnormalities detected by ultrasonography in the hip and groin region are common in patients with symptomatic hip dysplasia, and the ultrasonography findings of the iliopsoas and gluteus medius/minimus tendons are weakly to moderately correlated to pain related to muscles and tendons in these structures. Both...

  8. Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses.

    Science.gov (United States)

    Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed

    2013-10-01

    Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate.

  9. Intraoperative Ultrasonography during Drainage for Chronic Subdural Hematomas: A Technique to Release Isolated Deep-seated Hematomas—Technical Note

    Science.gov (United States)

    SHIMIZU, Satoru; MOCHIZUKI, Takahiro; OSAWA, Shigeyuki; KUMABE, Toshihiro

    2015-01-01

    After the drainage of chronic subdural hematomas (CSDHs), residual isolated deep-seated hematomas (IDHs) may recur. We introduce intraoperative ultrasonography to detect and remove such IDHs. Intra-operative ultrasonography is performed with fine transducers introduced via burr holes. Images obtained before dural opening show the CSDHs, hyper- and/or hypoechoic content, and mono- or multilayers. Images are also acquired after irrigation of the hematoma under the dura. Floating hyperechoic spots (cavitations) on the brain cortex created by irrigation confirm the release of all hematoma layers; areas without spots represent IDHs. Their overlying thin membranes are fenestrated with a dural hook for irrigation. Ultrasonographs were evaluated in 43 CSDHs (37 patients); 9 (21%) required IDH fenestration. On computed tomography scans, 17 were homogeneous-, 6 were laminar-, 16 were separated-, and 4 were trabecular type lesions. Of these, 2 (11.8%), 3 (50%), 4 (25%), and 0, respectively, manifested IDHs requiring fenestration. There were no technique-related complications. Patients subjected to IDH fenestration had lower recurrence rates (11.1% vs. 50%, p = 0.095) and required significantly less time for brain re-expansion (mean 3.78 ± 1.62 vs. 18 ± 5.54 weeks, p = 0.0009) than did 6 patients whose IDHs remained after 48 conventional irrigation and drainage procedures. Intraoperative ultrasonography in patients with CSDHs facilitates the safe release of hidden IDHs. It can be expected to reduce the risk of postoperative hematoma recurrence and to shorten the brain re-expansion time. PMID:26345671

  10. GLCM algorithm image analysis of nonalcoholic fatty liver and focal fat sparing zone in the ultrasonography

    International Nuclear Information System (INIS)

    Cho, Jin Young; Ye, Soo Young

    2017-01-01

    There is a need for aggressive diagnosis and treatment in middle-aged and high-risk individuals who are more likely to progress from nonalcoholic fatty liver to hepatitis. In this study, nonalcoholic fatty liver was divided into severe, moderate, and severe, and classified by quantitative method using computer analysis of GLCM algorithm. The purpose of this study was to evaluate the characteristics of ultrasound images in the local fat avoidance region. Normal, mild, moderate, severe fatty liver, and focal fat sparing area, 80 cases, respectively. Among the parameters of the GLCM algorithm, the values of the Autocorrelation, Square of the deviation, Sum of averages and Sum of variances with high recognition rate of the liver ultrasound image were calculated. The average recognition rate of the GLCM algorithm was 97.5%. The result of local fat avoidance image analysis showed the most similar value to the normal parenchyma. Ultrasonography can be easily accessed by primary screening, but there may be differences in the accuracy of the test method or the correspondence of results depending on proficiency. GLCM algorithm was applied to quantitatively classify the degree of fatty liver. Local fat avoidance region was similar to normal parenchyma, so it could be predicted to be homogeneous liver parenchyma without fat deposition. We believe that GLCM computer image analysis will provide important information for differentiating not only fatty liver but also other lesions

  11. Evaluation of abdominal fat index by ultrasonography and its relationship with psoriasis and metabolic syndrome.

    Science.gov (United States)

    Gönül, Müzeyyen; Tatar, İdil; Canpolat, Filiz; Işıl Kurmus, Gökçe; Ergin, Can; Hekimoğlu, Baki

    2017-10-01

    Accumulating evidence indicates that psoriasis is associated with obesity and metabolic syndrome. Psoriasis and obesity share similar inflammatory mediators, and obesity may potentiate some inflammatory cytokines seen in psoriasis. Body fat distribution, particularly visceral adipose tissue (VAT), is an important factor in metabolic syndrome and atherosclerotic diseases. An association has been demonstrated between psoriasis and abdominal VAT measured by computed tomography (CT). To measure abdominal VAT noninvasively by ultrasonography (USG) in patients with psoriasis and investigated its relation to psoriasis and metabolic syndrome. The study population consisted of 41 psoriasis patients and 41 control subjects matched for age, sex, and body mass index. The maximal preperitoneal fat thickness (Pmax) at the anterior surface of the liver and the minimal subcutaneous fat thickness (Smin) of the abdomen were measured by USG. The abdominal fat index (AFI = Pmax/Smin ratio) was calculated and the results were compared between groups. The rate of metabolic syndrome was significantly higher in psoriasis patients ( p = 0.0018). The mean AFI was similar in both groups. AFI was not associated with psoriasis in subjects with metabolic syndrome ( p = 0.495) or with Psoriasis Area and Severity Index ( r = 0.123, p = 0.443). This is the first study to evaluate abdominal VAT by USG. Computed tomography may be more reliable than USG, but its high cost and radiation exposure are major disadvantages. Further studies are required to determine the relationships between psoriasis and VAT.

  12. GLCM algorithm image analysis of nonalcoholic fatty liver and focal fat sparing zone in the ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jin Young [Dept. of Radiological Science, Graduate School of Catholic University of Pusan, Busan (Korea, Republic of); Ye, Soo Young [Dept. of Radiological Science, Catholic University of Pusan, Busan (Korea, Republic of)

    2017-06-15

    There is a need for aggressive diagnosis and treatment in middle-aged and high-risk individuals who are more likely to progress from nonalcoholic fatty liver to hepatitis. In this study, nonalcoholic fatty liver was divided into severe, moderate, and severe, and classified by quantitative method using computer analysis of GLCM algorithm. The purpose of this study was to evaluate the characteristics of ultrasound images in the local fat avoidance region. Normal, mild, moderate, severe fatty liver, and focal fat sparing area, 80 cases, respectively. Among the parameters of the GLCM algorithm, the values of the Autocorrelation, Square of the deviation, Sum of averages and Sum of variances with high recognition rate of the liver ultrasound image were calculated. The average recognition rate of the GLCM algorithm was 97.5%. The result of local fat avoidance image analysis showed the most similar value to the normal parenchyma. Ultrasonography can be easily accessed by primary screening, but there may be differences in the accuracy of the test method or the correspondence of results depending on proficiency. GLCM algorithm was applied to quantitatively classify the degree of fatty liver. Local fat avoidance region was similar to normal parenchyma, so it could be predicted to be homogeneous liver parenchyma without fat deposition. We believe that GLCM computer image analysis will provide important information for differentiating not only fatty liver but also other lesions.

  13. Ultrasonography and prostate-specific antigen (PSA) in differential diagnosis of prostate cancer and benign prostatic hyperplasia

    International Nuclear Information System (INIS)

    Mechev, D.S.; Shcherbyina, O.V.; Yatsik, V.Yi.; Gladka, L.Yu.

    2003-01-01

    The purpose of the work is analysis of diagnostic possibilities of transrectal ultrasonography and PSA in differential diagnosis of prostate cancer and benign prostatic hyperplasia. 142 patients have been investigated by transrectal ultrasonography. he transrectal ultrasonography and PSA are sensible tests in diagnosis of prostate cancer and in differential diagnosis of benign prostatic hyperplasia and prostate cancer

  14. Transrectal EUS-guided FNA biopsy of a presacral chordoma-report of a case and review of the literature

    Institute of Scientific and Technical Information of China (English)

    Klaus Gottlieb; Paul H Lin; David M Liu; Karl Anders

    2008-01-01

    Chordomas are rare tumors which originate from the remnants of the notochord.These tumors are locally aggressive and have a predilection for the ends of the axial skeleton.An important prerequisite for optimal management of these tumors is a correct preoperative diagnosis.The present case is the first report of the use of endoscopic ultrasound to obtain transrectal fine needle aspiration biopsy of a presacral chordoma.A review of the prior computer tomography (CT) scans allowed us to calculate the tumor volume doubling time (18.3 mo).Transrectal biopsy of chordomas is controversial,however we believe that such concerns are not justified.

  15. SU-E-I-30: Image Analysis in Ultrasonography for Diagnosis of Sjoegren's Syndrome Using Dual-Tree Complex Wavelet Transform

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, T [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Ohki, M [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka (Japan); Nakamura, T; Takagi, Y [Department of Radiology and Cancer Biology, Nagasaki University School of Dentistry, Nagasaki (Japan)

    2014-06-01

    Purpose: Sjoegren's syndrome (SS) is an autoimmune disease invading mainly salivary and lacrimal glands. Ultrasonography is used for an initial and non-invasive examination of this disease. However, the ultrasonography diagnosis tends to lack in objectivity and depends on the operator's skills. The purpose of this study is to propose a computer-aided diagnosis (CAD) system for SS based on a dual-tree complex wavelet transform (DT-CWT) and machine learning. Methods: The subjects of this study were 174 patients suspected of having SS at Nagasaki University Hospital and examined with ultrasonography of the parotid glands. Out of these patients, 77 patients were diagnosed with SS by sialography. A region of interest (ROI) of 128 × 128 pixels was set within the parotid gland that was indicated by a dental radiologist. The DT-CWT was applied to the images in the ROI and every image was decomposed into 72 sub-images of the real and imaginary components in six different resolution levels and six orientations. The statistical features of the sub-image were calculated and used as data input for the support vector machine (SVM) classifier for the detection of SS. A ten-fold cross-validation was employed to verify the Resultof SVM. The accuracy of diagnosis was compared by a CAD system with a human observer performance. Results: The sensitivity, specificity, and accuracy in the detection of SS were 95%, 86%, and 91% through our CAD system respectively, while those by a human observer were 84%, 81%, and 83% respectively. Conclusion: The proposed computer-aided diagnosis system for Sjoegren's syndrome in ultrasonography based on dual-tree complex wavelet transform had a better performance than a human observer.

  16. SU-E-I-30: Image Analysis in Ultrasonography for Diagnosis of Sjoegren's Syndrome Using Dual-Tree Complex Wavelet Transform

    International Nuclear Information System (INIS)

    Matsui, T; Ohki, M; Nakamura, T; Takagi, Y

    2014-01-01

    Purpose: Sjoegren's syndrome (SS) is an autoimmune disease invading mainly salivary and lacrimal glands. Ultrasonography is used for an initial and non-invasive examination of this disease. However, the ultrasonography diagnosis tends to lack in objectivity and depends on the operator's skills. The purpose of this study is to propose a computer-aided diagnosis (CAD) system for SS based on a dual-tree complex wavelet transform (DT-CWT) and machine learning. Methods: The subjects of this study were 174 patients suspected of having SS at Nagasaki University Hospital and examined with ultrasonography of the parotid glands. Out of these patients, 77 patients were diagnosed with SS by sialography. A region of interest (ROI) of 128 × 128 pixels was set within the parotid gland that was indicated by a dental radiologist. The DT-CWT was applied to the images in the ROI and every image was decomposed into 72 sub-images of the real and imaginary components in six different resolution levels and six orientations. The statistical features of the sub-image were calculated and used as data input for the support vector machine (SVM) classifier for the detection of SS. A ten-fold cross-validation was employed to verify the Resultof SVM. The accuracy of diagnosis was compared by a CAD system with a human observer performance. Results: The sensitivity, specificity, and accuracy in the detection of SS were 95%, 86%, and 91% through our CAD system respectively, while those by a human observer were 84%, 81%, and 83% respectively. Conclusion: The proposed computer-aided diagnosis system for Sjoegren's syndrome in ultrasonography based on dual-tree complex wavelet transform had a better performance than a human observer

  17. Emergency ultrasonography of the gastrointestinal tract of children

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae Yeon [Dept. of Radiology, Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of)

    2017-07-15

    Ultrasonography (US) is widely used to evaluate most body parts in pediatric patients because it is simple, noninvasive, easy to use, and applicable in a wide variety of clinical situations. US is the modality of choice for the initial evaluation of acute abdominal pain in pediatric patients because of their small body habitus and the presence of less fat tissue in the abdominal wall and peritoneal cavity. The most important factor in performing pediatric emergency US is the graded compression technique and selection of the proper transducer. The careful evaluation of bowel wall thickening combined with ancillary findings such as fluid collection, increased echogenicity of the mesenteric fat tissue, enlarged lymph nodes, hyperemic bowel changes, and abnormal bowel peristalsis can increase the diagnostic capability of US.

  18. Ultrasonography-guided cobalt-60 brachytherapy for malignant glioma

    International Nuclear Information System (INIS)

    Sakai, Noboru; Takenaka, Katsunobu; Ueda, Tatsuya

    1989-01-01

    Brachytherapy with cobalt-60 source is reported. In this method it is characterized that the source is inserted interstitially with remote control system by after-loading method via outer catheter (using tandem tube), which was established in the center of residual tumor, using ultrasonography guide with trepanation, or intraoperatively put within the dead space after tumor resection. Six cases of deep-seated and recurrent malignant glioma, were treated with this method. A total dose of 20 to 45 Gy (10 to 15 Gy/day for 2 to 3 days) was delivered to the target. Additionally conventional external irradiation was followed. The effect of cobalt-60 brachytherapy on such tumors were favorable especially for well-circumscribed glioma less than 3 cm on CT scan. (author)

  19. Ultrasonography, CT, and ERCP in the diagnosis of choledochal stones

    International Nuclear Information System (INIS)

    Pasanen, P.; Partanen, K.; Pikkarainen, P.; Alhava, E.; Pirinen, A.; Janatuinen, E.

    1992-01-01

    A prospective study of jaundiced (n = 187) and nonjaundiced (n = 33) cholestatic patients was carried out to evaluate the sensitivity of ultrasonography (US), CT and endoscopic retrograde cholangiopancreatography (ERCP) in the detection of choledochal stone disease. Altogether 83 patients had the final diagnosis of choledocholithiasis. In the jaundiced patients, the sensitivity of US, CT, and ERCP was 22,5%, 23,2%, and 80,6%, respectively. In cases of cholestasis without jaundice, the values were 20%, 37,5%, and 66,7%. In patients in whom all 3 imaging studies were done (n = 64), the differences between US and ERCP and between CT and ERCP were statistically significant (p < 0.0001). In most false-negative ERCP studies (10/15), the clinical course of the disease strongly suggested a passed choledochal stone. On the basis of this study, we recommend prompt ERCP to be performed if choledochal stone disease is suspected on clinical grounds. (orig.)

  20. Medical auditing of whole-breast screening ultrasonography.

    Science.gov (United States)

    Kim, Min Jung

    2017-07-01

    Since breast ultrasonography (US) has been used as an adjunctive screening modality in women with dense breasts, the need has arisen to evaluate and monitor its possible harm and benefits in comparison with other screening modalities such as mammography. Recently, the fifth edition of the Breast Imaging Reporting and Data System published by the American College of Radiology has suggested auditing methods for screening breast US. However, the method proposed therein is slightly different from how diagnostic performance was calculated in previous studies on screening breast US. In this article, the background and core aspects of medical audits of breast cancer screening will be reviewed to provide an introduction to the medical auditing of screening breast US, with the goal of helping radiologists to understand and identify potential ways to improve outcomes.

  1. The core content of clinical ultrasonography fellowship training.

    Science.gov (United States)

    Lewiss, Resa E; Tayal, Vivek S; Hoffmann, Beatrice; Kendall, John; Liteplo, Andrew S; Moak, James H; Panebianco, Nova; Noble, Vicki E

    2014-04-01

    The purpose of developing a core content for subspecialty training in clinical ultrasonography (US) is to standardize the education and qualifications required to provide oversight of US training, clinical use, and administration to improve patient care. This core content would be mastered by a fellow as a separate and unique postgraduate training, beyond that obtained during an emergency medicine (EM) residency or during medical school. The core content defines the training parameters, resources, and knowledge of clinical US necessary to direct clinical US divisions within medical specialties. Additionally, it is intended to inform fellowship directors and candidates for certification of the full range of content that might appear in future examinations. This article describes the development of the core content and presents the core content in its entirety. © 2014 by the Society for Academic Emergency Medicine.

  2. Medical auditing of whole-breast screening ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Jung [Dept. of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-07-15

    Since breast ultrasonography (US) has been used as an adjunctive screening modality in women with dense breasts, the need has arisen to evaluate and monitor its possible harm and benefits in comparison with other screening modalities such as mammography. Recently, the fifth edition of the Breast Imaging Reporting and Data System published by the American College of Radiology has suggested auditing methods for screening breast US. However, the method proposed therein is slightly different from how diagnostic performance was calculated in previous studies on screening breast US. In this article, the background and core aspects of medical audits of breast cancer screening will be reviewed to provide an introduction to the medical auditing of screening breast US, with the goal of helping radiologists to understand and identify potential ways to improve outcomes.

  3. Emergency ultrasonography of the gastrointestinal tract of children

    International Nuclear Information System (INIS)

    Hwang, Jae Yeon

    2017-01-01

    Ultrasonography (US) is widely used to evaluate most body parts in pediatric patients because it is simple, noninvasive, easy to use, and applicable in a wide variety of clinical situations. US is the modality of choice for the initial evaluation of acute abdominal pain in pediatric patients because of their small body habitus and the presence of less fat tissue in the abdominal wall and peritoneal cavity. The most important factor in performing pediatric emergency US is the graded compression technique and selection of the proper transducer. The careful evaluation of bowel wall thickening combined with ancillary findings such as fluid collection, increased echogenicity of the mesenteric fat tissue, enlarged lymph nodes, hyperemic bowel changes, and abnormal bowel peristalsis can increase the diagnostic capability of US

  4. Cholangiocarcinoma in Magnetic Resonance Cholangiopancreatography and Fascioliasis in Endoscopic Ultrasonography

    Directory of Open Access Journals (Sweden)

    Amir Houshang Mohammad Alizadeh

    2011-10-01

    Full Text Available Fascioliasis is a worldwide zoonotic infection with Fasciola hepatica and Fasciola gigantica. The zoonoses are particularly endemic in sheep-raising countries and are also endemic in Iran. Typical symptoms that may be associated with fascioliasis can be divided by phases of the disease, including the acute or liver phase, the chronic or biliary phase, and ectopic or pharyngeal fascioliasis. Cholestatic symptoms may be absent, and in some cases diagnosis and treatment may be preceded by a long period of abdominal pain, eosinophilia and vague gastrointestinal symptoms. We report a case with epigastric and upper quadrant abdominal pain for the last 4 years, with imaging suggesting cholangiocarcinoma. Considering a new concept of endoscopic ultrasonography, at last F. hepatica was extracted with endoscopic retrograde cholangiography.

  5. Ultrasonography of small intestinal obstructions: a contemporary approach.

    Science.gov (United States)

    Garcia, D A A; Froes, T R; Vilani, R G D O C; Guérios, S D; Obladen, A

    2011-09-01

    To assess the accuracy of intestinal ultrasound for diagnosis of intestinal obstruction in dogs and cats. A prospective clinical study was performed. Inclusion criteria were dogs and cats with clinical signs suggestive of gastrointestinal obstruction. Animals with no obstruction detected on ultrasound were excluded if they could not be monitored for 48 hours to confirm absence of obstruction. Sonographic diagnosis of small intestinal obstruction was based on identification of at least two findings suggestive of intestinal obstruction. Ninety-two patients suspected of having intestinal obstruction were included. Correct diagnosis of intestinal obstruction was made in 21 cases (23%), and in 68 (74%) this diagnosis was excluded. Interpretation of the images on prospective analysis had sensitivity, positive predictive, specificity and negative predictive values of 100%, 87.5%, 95.8% and 100%, respectively. Ultrasonography is an excellent method for investigation of animals with gastrointestinal disorders, and is particularly useful for excluding obstructive processes. © 2011 British Small Animal Veterinary Association.

  6. Bedside Ultrasonography: A Useful Tool For Traumatic Pneumothorax

    International Nuclear Information System (INIS)

    Mumtaz, U.; Zahur, Z.; Chaudhry, M. A.; Warraich, R. A.

    2016-01-01

    Objective: To compare the diagnostic accuracy of bedside ultrasound and supine chest radiography for the diagnosis of traumatic pneumothorax. Study Design: Analytical study. Place and Duration of Study: PIMS and PAEC General Hospital, Islamabad, from November 2014 to August 2015. Methodology: Patients coming to emergency departments of the study centres, who had sustained chest injuries, were inducted. Their portable bedside ultrasound and supine chest radiographs were taken for assessing pneumothorax and subsequently CT chest was done for confirmation as gold standard. Result: Based on CT findings, sensitivity for ultrasonography and chest radiography was found to be 83.33 percentage and 54.76 percentage, respectively and specificity of 100 percentage for both modalities. Conclusion: Ultrasound can be used as a useful and suitable adjunct to CT in trauma patients as it is easily available, non-invasive, bedside, easily examined with no radiation risk. (author)

  7. An audit of ultrasonography performed and reported by trainee radiologists.

    Science.gov (United States)

    Eze, K C; Marchie, T T; Eze, C U

    2009-01-01

    Proforma information, instructions and procedures of training in radiology are lacking in Nigeria. To describe the errors in ultrasonography performed by unsupervised trainee radiologists. The radiology records of all ultrasound scans (USS) carried out and all reports that came back to the unit of the authors on account of misdiagnosis, doubtful diagnosis, misinformation or error in the reports were studied. The patients with the returned reports were rescanned where available by consultants and the collected data analysed. A total of 4680 patients had ultrasound studies without supervision resulting in 605 (12.93%) queried reports. The USS scans of 235 (5.02%) patients were repeated with consultants in attendance resulting in significant change in reports of 95 (2.03%) patients. Analysis of the request cards of 605 queried reports showed omission of relevant clinical information 463 (76.53%), outright wrong information 65 (10.73%),and unconventional abbreviations 139 (22.98%), while 493 (81.49%) were completed by a nurse, medical student or junior resident. Typographical errors comprised 174 (28.76%) of the 605 queried reports. False negative error was the highest type of error seen in 55 (57.89%) of the 95 patients with significant change in their report after repeat scan as lesions not detected were not documented. Trainee radiologists make significant errors in carrying out and reporting ultrasonography without adequate direct supervision of the study by their training consultants. Majority of the errors originate from lack of accurate filling of the patients request cards by the requesting physicians, lack of adequate preparation for the intended study, and typographical errors in writing reports. False negative reports are by far the greatest cause of errors recorded as lesions not detected were not documented.

  8. Adaptive sound speed correction for abdominal ultrasonography: preliminary results

    Science.gov (United States)

    Jin, Sungmin; Kang, Jeeun; Song, Tai-Kyung; Yoo, Yangmo

    2013-03-01

    Ultrasonography has been conducting a critical role in assessing abdominal disorders due to its noninvasive, real-time, low cost, and deep penetrating capabilities. However, for imaging obese patients with a thick fat layer, it is challenging to achieve appropriate image quality with a conventional beamforming (CON) method due to phase aberration caused by the difference between sound speeds (e.g., 1580 and 1450m/s for liver and fat, respectively). For this, various sound speed correction (SSC) methods that estimate the accumulated sound speed for a region-of interest (ROI) have been previously proposed. However, with the SSC methods, the improvement in image quality was limited only for a specific depth of ROI. In this paper, we present the adaptive sound speed correction (ASSC) method, which can enhance the image quality for whole depths by using estimated sound speeds from two different depths in the lower layer. Since these accumulated sound speeds contain the respective contributions of layers, an optimal sound speed for each depth can be estimated by solving contribution equations. To evaluate the proposed method, the phantom study was conducted with pre-beamformed radio-frequency (RF) data acquired with a SonixTouch research package (Ultrasonix Corp., Canada) with linear and convex probes from the gel pad-stacked tissue mimicking phantom (Parker Lab. Inc., USA and Model539, ATS, USA) whose sound speeds are 1610 and 1450m/s, respectively. From the study, compared to the CON and SSC methods, the ASSC method showed the improved spatial resolution and information entropy contrast (IEC) for convex and linear array transducers, respectively. These results indicate that the ASSC method can be applied for enhancing image quality when imaging obese patients in abdominal ultrasonography.

  9. Interobserver agreement on the interpretation of automated whole breast ultrasonography

    International Nuclear Information System (INIS)

    Kim, Eun Jeong; KIm, Sung Hun; Kang, Bong Joo; Kim, Yun Ju

    2014-01-01

    The purpose of this study was to prospectively evaluate the interobserver agreement on lesion characterization and the final assessment of automated whole breast ultrasonography (ABUS) images. Between March and August 2012, 172 women underwent bilateral ABUS before biopsy guided by handheld ultrasonography (HHUS) and mammography. A total of 206 breast lesions were confirmed histopathologically by biopsy. Three-dimensional volume data from ABUS scans were analyzed by two radiologists without the knowledge of HHUS results or patient clinical information. The two readers described the type, shape, orientation, margin, echogenicity, posterior acoustic features, and categorization of the final assessment of detected breast lesions. Kappa statistics were used to analyze the described characteristics of the breast lesions detected by both of the two readers. Of the 206 histopathologically confirmed lesions, reader 1 detected 166 lesions and reader 2 detected 150 lesions. A total of 145 lesions were detected by both readers using ABUS images. There was substantial agreement on shape (k=0.707), and moderate agreement on type, margin, mass orientation, echogenicity, and posterior acoustic features (k=0.592, 0.438, 0.472, 0.524, and 0.541, respectively). Breast Imaging Reporting and Data System final assessment values yielded a kappa value of 0.3971 when category subdivisions 4A, 4B, and 4C were included. With respect to the C2, C3, C4, and C5 categories, the interobserver agreement was moderate (k=0.505). ABUS is a promising diagnostic tool with a good interobserver agreement, comparable to that of HHUS.

  10. Interobserver agreement on the interpretation of automated whole breast ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Jeong; KIm, Sung Hun; Kang, Bong Joo; Kim, Yun Ju [Dept. of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    The purpose of this study was to prospectively evaluate the interobserver agreement on lesion characterization and the final assessment of automated whole breast ultrasonography (ABUS) images. Between March and August 2012, 172 women underwent bilateral ABUS before biopsy guided by handheld ultrasonography (HHUS) and mammography. A total of 206 breast lesions were confirmed histopathologically by biopsy. Three-dimensional volume data from ABUS scans were analyzed by two radiologists without the knowledge of HHUS results or patient clinical information. The two readers described the type, shape, orientation, margin, echogenicity, posterior acoustic features, and categorization of the final assessment of detected breast lesions. Kappa statistics were used to analyze the described characteristics of the breast lesions detected by both of the two readers. Of the 206 histopathologically confirmed lesions, reader 1 detected 166 lesions and reader 2 detected 150 lesions. A total of 145 lesions were detected by both readers using ABUS images. There was substantial agreement on shape (k=0.707), and moderate agreement on type, margin, mass orientation, echogenicity, and posterior acoustic features (k=0.592, 0.438, 0.472, 0.524, and 0.541, respectively). Breast Imaging Reporting and Data System final assessment values yielded a kappa value of 0.3971 when category subdivisions 4A, 4B, and 4C were included. With respect to the C2, C3, C4, and C5 categories, the interobserver agreement was moderate (k=0.505). ABUS is a promising diagnostic tool with a good interobserver agreement, comparable to that of HHUS.

  11. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    Science.gov (United States)

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  12. Ultrasonography of pleural effusion. The quantification of minimal detectable volume

    International Nuclear Information System (INIS)

    Sustic, A.; Medved, I.; Ekl, D.; Simic, O.; Kovac, D.; Ivanis, N.

    2001-01-01

    Background. The aim of this study was to establish a minimal volume of free thoracic fluid in the pleural space of the supine cadaver detectable by ultrasonography. Material and methods. A prospective study with an experimental model on 20 cadavers (10 male, 10 female; age 66 ±11 yr.; height 172 ±9 cm; weight 75 ±12.6 kg; body surface area (BSA) 1.87 ±0.2 m 2 ) was used. Each cadaver was punctured bilaterally in 5 th or 6 th intercostal space at the medioclavicular line with venous cannula infusing in NaCl 0,9% solution at randomised speed in the chest. During the procedure the laterodorsal part of the thoracic wall next to the pulmonal base and phrenicocostal sinus was ultrasonographically scanned. At the moment of the visualisation of anechogenic line pertaining to the free fluid between dorsal thoracic wall and lungs, the installation was stopped and the amount of injected fluid verified. Results. Minimal, by ultrasonography detectable amount of free fluid in the right pleural space was 223±52 ml with the significant positive correlation to height (r = 0.69; p < 0.001), weight (r 0.68; p < 0.01) and the BSA (r = 0.71; p < 0.001) of cadaver. Detectable volume in the left pleural space was notably smaller than contra lateral, namely 172±53 ml also with a significant correlation to the cadaver's height (r = 0.55; p < 0.05), weight (r = 0.59; p < 0.01) and BSA (r = 0.60; p < 0.01). Conclusions. The authors affirm that ultrasonographically detectable quantity of free fluid in the chest positively correlates with height, weight and BSA of cadavers, and that the measured amount in the supine position is approximately 223 ml for the right space versus 172 ml for the left pleural space. (author)

  13. EUS-guided biliary drainage by using a standardized approach for malignant biliary obstruction: rendezvous versus direct transluminal techniques (with videos).

    Science.gov (United States)

    Khashab, Mouen A; Valeshabad, Ali Kord; Modayil, Rani; Widmer, Jessica; Saxena, Payal; Idrees, Mehak; Iqbal, Shahzad; Kalloo, Anthony N; Stavropoulos, Stavros N

    2013-11-01

    EUS-guided biliary drainage (EGBD) can be performed via direct transluminal or rendezvous techniques. It is unknown how both techniques compare in terms of efficacy and adverse events. To describe outcomes of EGBD performed by using a standardized approach and compare outcomes of rendezvous and transluminal techniques. Retrospective analysis of prospectively collected data. Two tertiary-care centers. Consecutive jaundiced patients with distal malignant biliary obstruction who underwent EGBD after failed ERCP between July 2006 and December 2012 were included. EGBD by using a standardized algorithm. Technical success, clinical success, and adverse events. During the study period, 35 patients underwent EGBD (rendezvous n = 13, transluminal n = 20). Technical success was achieved in 33 patients (94%), and clinical success was attained in 32 of 33 patients (97.0%). The mean postprocedure bilirubin level was 1.38 mg/dL in the rendezvous group and 1.33 mg/dL in the transluminal group (P = .88). Similarly, length of hospital stay was not different between groups (P = .23). There was no significant difference in adverse event rate between rendezvous and transluminal groups (15.4% vs 10%; P = .64). Long-term outcomes were comparable between groups, with 1 stent migration in the rendezvous group at 62 days and 1 stent occlusion in the transluminal group at 42 days after EGBD. Retrospective analysis, small number of patients, and selection bias. EGBD is safe and effective when the described standardized approach is used. Stent occlusion is not common during long-term follow-up. Both rendezvous and direct transluminal techniques seem to be equally effective and safe. The latter approach is a reasonable alternative to rendezvous EGBD. Copyright © 2013. Published by Mosby, Inc.

  14. Feasibility of ultrasonography and MR arthrography during evaluation of rotator cuff injury

    International Nuclear Information System (INIS)

    Hu, Jin Guang; Lee, Jong Min; Ryeom, Hun Kyu

    2005-01-01

    To evaluate the feasibility of MR arthrography and ultrasonography in evaluating shoulder pain. The subject group consisted of all patients who visited our institute complaining of shoulder pain or instability form June 2002 to December 2004. There were a total of 92 patients with an mean age of 48. On the basis of arthroscopic results, the sensitivity, specificity, and accuracy of ultrasonography and MR arthrography were evaluated by comparing them with each other. In the diagnosis of separateness tendon tears, ultrasonography had sensitivity and specificity of 100% and 64%, respectively, whereas MR arthrography had sensitivity and specificity of 80% and 94%, respectively. Ultrasonography also had high sensitivity and specificity in the diagnosis of subscapularis tendon tears (100% and 90%). MR arthrography was appropriate for identifying glenoid labral abnormalities (sensitivity, 95% and specificity, 61%). Similar results from ultrasonography and MR arthrography were obtained in the diagnosis of subscapular tendon tears or full-thickness tears of the rotator cuff tendons (kappa value, 0.644 and 0.911). While evaluating rotator cuff abnormalities, ultrasonography was appropriate for screening, whereas MR arthrography was useful to confirm the results of the ultrasonography

  15. Comparison between mammography and ultrasonography for palpable breast mass: focusing fibroadenoma and breast cancer

    International Nuclear Information System (INIS)

    Kim, Do Kyun; Koh, Mi Kyung; Choi, Chul Soon; Chung, Soo Young; Yi, Jeong Geun; Yoon, Dae Young; Kim, Ho Chul; Bae, Sang Hoon

    1997-01-01

    The purpose of our study was to compare the diagnostic accuracy of mammography and breast ultrasonography between fibroadenoma and palpable breast cancer and to evaluate the feasibility of ultrasonography as a primary diagnostic modality to differentiate between these two tumor types. In 36 cases of fibroadenoma and 35 of breast cancer, all palpable and pathologically-proven, the diagnostic accuracy of mammography and ultrasonography was retros-pectively analysed. In fibroadenoma cases, the diagnostic accuracy of mammography and ultrasonography was 53% and 80%, respectively, and the difference was statistically significant(p=3D0.0162). In cases of breast cancer, the corresponding figures were 74% and 82%, respectively;the difference was not statistically signigicant(p-0.55). Overall, the diagnostic accuracy of mammography and ultrasonog-raphy was 63% and 82%, respectively, and this difference was statistically significant(p=3D0.0164). The total diagnostic accuracy of both studies was 90%, and this was signigicantly different(p=3D0.044) from that of ultrasonography(82%). In patients who have clinically palpable breast masses, ultrasonography can be recommended as the primary diagnostic modality, though for other breast lesions, mammography is the recommended primary modality.=20

  16. Comparison between mammography and ultrasonography for palpable breast mass: focusing fibroadenoma and breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Kyun; Koh, Mi Kyung; Choi, Chul Soon; Chung, Soo Young; Yi, Jeong Geun; Yoon, Dae Young; Kim, Ho Chul; Bae, Sang Hoon [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-09-01

    The purpose of our study was to compare the diagnostic accuracy of mammography and breast ultrasonography between fibroadenoma and palpable breast cancer and to evaluate the feasibility of ultrasonography as a primary diagnostic modality to differentiate between these two tumor types. In 36 cases of fibroadenoma and 35 of breast cancer, all palpable and pathologically-proven, the diagnostic accuracy of mammography and ultrasonography was retros-pectively analysed. In fibroadenoma cases, the diagnostic accuracy of mammography and ultrasonography was 53% and 80%, respectively, and the difference was statistically significant(p=3D0.0162). In cases of breast cancer, the corresponding figures were 74% and 82%, respectively;the difference was not statistically signigicant(p-0.55). Overall, the diagnostic accuracy of mammography and ultrasonog-raphy was 63% and 82%, respectively, and this difference was statistically significant(p=3D0.0164). The total diagnostic accuracy of both studies was 90%, and this was signigicantly different(p=3D0.044) from that of ultrasonography(82%). In patients who have clinically palpable breast masses, ultrasonography can be recommended as the primary diagnostic modality, though for other breast lesions, mammography is the recommended primary modality.=20.

  17. Pretreatment Evaluation with Contrast-Enhanced Ultrasonography for Percutaneous Radiofrequency Ablation of Hepatocellular Carcinomas with Poor Conspicuity on Conventional Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Ah Yeong; Lee, Min Woo; Rhim, Hyunchul; Cha, Dong Ik; Choi, Dongil; Kim, Young-sun; Lim, Hyo Keun; Cho, Seong Whi

    2013-01-01

    To determine whether pretreatment evaluation with contrast-enhanced ultrasonography (CEUS) is effective for percutaneous radiofrequency ablation (RFA) of hepatocellular carcinoma (HCC) with poor conspicuity on conventional ultrasonography (US). This retrospective study was approved by the institutional review board and informed consent was waived. From June 2008 to July 2011, 82 patients having HCCs (1.2 ± 0.4 cm) with poor conspicuity on planning US for RFA were evaluated with CEUS prior to percutaneous RFA. We analyzed our database, radiologic reports, and US images in order to determine whether the location of HCC candidates on planning US coincide with that on CEUS. To avoid incomplete ablation, percutaneous RFA was performed only when HCC nodules were identified on CEUS. The rate of technical success was assessed. The cumulative rate of local tumor progression was estimated with the use of the Kaplan-Meier method (mean follow-up: 24.0 ± 13.0 months). Among 82 patients, 73 (89%) HCCs were identified on CEUS, whereas 9 (11%) were not. Of 73 identifiable HCCs on CEUS, the location of HCC on planning US corresponded with that on CEUS in 64 (87.7%), whereas the location did not correspond in 9 (12.3%) HCCs. Technical success was achieved for all 73 identifiable HCCs on CEUS in a single (n = 72) or two (n = 1) RFA sessions. Cumulative rates of local tumor progression were estimated as 1.9% and 15.4% at 1 and 3 years, respectively. Pretreatment evaluation with CEUS is effective for percutaneous RFA of HCCs with poor conspicuity on conventional US

  18. Infusion tomography and ultrasonography of the gallbladder in the diagnosis of acute cholecystitis

    International Nuclear Information System (INIS)

    Karp, W.; Owman, T.; Herlin, P.; Holmin, T.

    1979-01-01

    Sixty-three patients with the clinical suspicion of acute cholecystitis were examined with infusion tomography of the gallbladder. Ultrasonography was performed in 51 of these cases. The technique and diagnostic principles of both methods are discussed. The diagnostic value of the two methods when used in combination is stressed. Thus in a case of gangrenous cholecystitis when opacification of the gallbladder wall may not appear at infusion tomography, ultrasonography may demonstrate signs of gallbladder disease. Infusion tomography, on the other hand, may be of great value if ultrasonography is not informative. (orig.) 891 AJ/orig. 892 BRE [de

  19. Shear-wave elastography in breast ultrasonography: the state of the art

    Directory of Open Access Journals (Sweden)

    Ji Hyun Youk

    2017-10-01

    Full Text Available Shear-wave elastography (SWE is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy.

  20. Shear-wave elastography in breast ultrasonography: the state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Youk, Ji Hyun; Gweon, Hye Mi; Son, Eun Ju [Dept. of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    Shear-wave elastography (SWE) is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy.

  1. Determination of gestational age by ultrasonography - wrong, wrong and wrong again?

    International Nuclear Information System (INIS)

    Bratlid, D.

    1991-01-01

    The article is a critical review of principal weaknesses in the current use of ultrasonography for determination of gestational age and discusses the fact that the method in its practical use disregards any biological variation in biparietal diameter. It is concluded that second trimester determination of gestational age by ultrasonography has an accuracy no greater than ±1.5 weeks. This is comparable to the accuracy of the clinical assessment of maturation in the newborn baby. Ultrasonography as the main indicator of gestational age should be used only when the pregnant woman's own menstrual history is obviously incorrect. 6 refs., 1 fig

  2. Validation of ultrasonography in detecting structural disease of the urogenital tract of the koala, Phascolarctos cinereus.

    Science.gov (United States)

    Marschner, C; Flanagan, C; Higgins, D P; Krockenberger, M B

    2014-05-01

    A retrospective review of case records of ultrasonography and necropsy outcomes of 62 koalas was used to investigate the accuracy of ultrasonography in assessing koala urogenital tract structural disease at the Port Macquarie Koala Hospital. The results showed high concordance, supporting ultrasonography as an effective tool for evaluating structural disease of the koala urogenital tract, most commonly seen with chlamydiosis. The study also illustrates the advances benefiting animal welfare that can be made by wildlife carer groups through using a scientific, evidence-based approach. © 2014 Australian Veterinary Association.

  3. MRI and endoscopic ultrasonography in the staging of gastric cancer Resonancia magnética y ecoendoscopia para el estadiaje del cáncer gástrico

    Directory of Open Access Journals (Sweden)

    M. G. Arocena

    2006-08-01

    Full Text Available Objective: to determine the diagnostic precision of endoscopic ultrasounds (EUS and magnetic resonance imaging (MRI in the preoperative staging of gastric cancer. Methods: a prospective, blind study was carried out in 17 patients diagnosed with gastric cancer (GC using endoscopic biopsy from November 2002 to June 2003. Patients underwent preoperative MRI and EUS. The reference test used was pathology, and laparotomy for non-resectable cases. Results: MRI (53% was better than EUS in the assessment of gastric wall infiltration (35%. MRI (50% was also superior to EUS (42% for N staging. After pooling stages T1-T2 and T3-T4 together, results improved for both MRI (67 and 87.5%, respectively and EUS (67 and 62.5%, respectively (p < 0.05. N staging -lymph node invasion- results were correct in 50% for MRI as compared to EUS (42%. In classifying positive and negative lymph nodes EUS was superior to MRI (73 versus 54%. Conclusions: MRI was the best method in the assessment of gastric wall infiltration. EUS was superior to MRI for T1 staging, and in the assessment of lymph node infiltration.

  4. EUS-guided drainage of pancreatic fluid collections using a novel lumen-apposing metal stent on an electrocautery-enhanced delivery system: a large retrospective study (with video).

    Science.gov (United States)

    Rinninella, Emanuele; Kunda, Rastislav; Dollhopf, Markus; Sanchez-Yague, Andres; Will, Uwe; Tarantino, Ilaria; Gornals Soler, Joan; Ullrich, Sebastian; Meining, Alexander; Esteban, Josè Miguel; Enz, Thomas; Vanbiervliet, Geoffroy; Vleggaar, Frank; Attili, Fabia; Larghi, Alberto

    2015-12-01

    A lumen-apposing, self-expanding metal stent incorporated in an electrocautery-enhanced delivery system for EUS-guided drainage of pancreatic fluid collections (PFCs) recently has become available. The aim of this study was to analyze the safety and clinical effectiveness of this newly developed device in this clinical setting. This was a retrospective analysis of all consecutive patients with PFCs who underwent EUS-guided drainage using the study device in 13 European centers. Ninety-three patients with PFCs (80% with complex collections) underwent drainage using the study device. Penetration of the PFC was accomplished directly with the study device in 74.2% of patients, and successful stent placement was accomplished in all but 1 patient, mostly without fluoroscopic assistance. Direct endoscopic necrosectomy (DEN) was carried out in 31 of 52 cases (59.6%) of walled-off necrosis and in 2 of 4 cases (50%) of acute peripancreatic fluid collection. Complete resolution of the PFC was obtained in 86 cases (92.5%), with no recurrence during follow-up. Treatment failure occurred in 6 patients because of persistent infection requiring surgery (n = 3), perforation and massive bleeding caused by the nasocystic drainage catheter (NCDC) (n = 2), and the need for a larger opening to extract large necrotic tissue pieces (n = 1). Major adverse events occurred in 5 patients (perforation and massive bleeding caused by the NCDC in 2 patients, 1 pneumoperitoneum and 1 stent dislodgement during DEN, and 1 postdrainage infection) and were mostly not related to the drainage procedure. EUS-guided drainage with the electrocautery-enhanced delivery system is a safe, easy to perform, and a highly effective minimally invasive treatment modality for PFCs. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  5. Diagnostic accuracy and therapeutic impact of endoscopic ultrasonography in patients with intermediate suspicion of choledocholithiasis and absence of findings in magnetic resonance cholangiography Precisión diagnóstica e impacto terapéutico de la ultrasonografía endoscópica en los pacientes con sospecha intermedia de coledocolitiasis y colangiorresonancia normal

    Directory of Open Access Journals (Sweden)

    Enrique Vázquez-Sequeiros

    2011-09-01

    Full Text Available Background: endoscopic ultrasonography (EUS and magnetic resonance cholangiography (MRC are the elective tests in the diagnosis of choledocholithiasis. MRC is best accepted by patients, but its sensitivity might decrease in the evaluation of microlithiasis. Aim: to evaluate the diagnostic accuracy and therapeutic impact of EUS in a prospective cohort of patients with intermediate suspicion of choledocolithiasis and no findings in MRC (normal MRC. Material and methods: during a period of 24 months, all the patients with clinical intermediate suspicion of choledocholithiasis and normal MRC were included. Sensitivity, specificity, diagnostic accuracy, positive predictive value (PPV and negative predictive value (NPV of MRC and EUS were compared, and so their impact in the management of these patients. Results: seventy six patients were evaluated (lithiasis in 30% of them. Sensitivity and diagnostic accuracy of EUS (100%, 92% were significantly higher than MRC values (0%, 70% (p Antecedentes: la ultrasonografía endoscópica (USE y la colangiografía por resonancia magnética nuclear (CRM son las técnicas de elección para el diagnóstico de litiasis en la vía biliar. Aunque la CRM es mejor aceptada por los pacientes, la sensibilidad de esta para detectar litiasis de pequeño tamaño podría ser insuficiente. Objetivo: estudiar de forma prospectiva la precisión diagnóstica y el impacto terapéutico de la USE en los pacientes con sospecha intermedia de coledocolitiasis y CRM normal. Material y métodos: se incluyeron prospectivamente durante 24 meses todos los pacientes con sospecha clínica intermedia de coledocolitiasis y CRM negativa. Se compar�� la sensibilidad, especificidad, precisión diagnóstica, valor predictivo positivo y negativo de CRM y USE, así como su impacto en el tratamiento. Resultados: se evaluaron 76 pacientes (litiasis en el 30%. La sensibilidad y precisión diagnóstica de USE (100%, 92% eran significativamente

  6. Morphological changes after pelvic floor muscle training measured by 3-dimensional ultrasonography: a randomized controlled trial.

    Science.gov (United States)

    Braekken, Ingeborg Hoff; Hoff Braekken, Ingeborg; Majida, Memona; Engh, Marie Ellström; Bø, Kari

    2010-02-01

    To investigate morphological and functional changes after pelvic floor muscle training in women with pelvic organ prolapse. This randomized controlled trial was conducted at a university hospital and a physical therapy clinic. One hundred nine women with pelvic organ prolapse stages I, II, and III were randomly allocated by a computer-generated random number system to pelvic floor muscle training (n=59) or control (n=50). Both groups received lifestyle advice and learned to contract the pelvic floor muscles before and during increases in intraabdominal pressure. In addition the pelvic floor muscle training group did individual strength training with a physical therapist and daily home exercise for 6 months. Primary outcome measures were pelvic floor muscle (pubovisceral muscle) thickness, levator hiatus area, pubovisceral muscle length at rest and Valsalva, and resting position of bladder and rectum, measured by three-dimensional ultrasonography. Seventy-nine percent of women in the pelvic floor muscle training group adhered to at least 80% of the training protocol. Compared with women in the control group, women in the pelvic floor muscle training group increased muscle thickness (difference between groups: 1.9 mm, 95% confidence interval [CI] 1.1-2.7, Ppelvic floor muscle stiffness. Supervised pelvic floor muscle training can increase muscle volume, close the levator hiatus, shorten muscle length, and elevate the resting position of the bladder and rectum. www.clinicaltrials.gov, NCT00271297. I.

  7. Ultrasonography and contrast-enhanced CT findings of tularemia in the neck.

    Science.gov (United States)

    Doğan, Serap; Ekinci, Afra; Demiraslan, Hayati; Ulu Kılıç, Ayşegül; Mavili, Ertuğrul; Öztürk, Mustafa; İmamoğlu, Hakan; Doğanay, Mehmet

    2016-01-01

    We aimed to evaluate the ultrasonography (US) and contrast-enhanced computed tomography (CECT) findings of tularemia in the neck. US and CECT findings of 58 patients with serologically proven tularemia were retrospectively evaluated. Forty-eight patients underwent US and 42 patients underwent CECT. Lymph node characteristics and parotid preauricular region involvement were analyzed using US and CECT. In addition, involvement of larynx, oropharynx, and retropharynx; presence of periorbital edema; and neck abscess formation were evaluated using CECT. Fine needle aspiration cytology (FNAC) results of enlarged lymph nodes were analyzed in 29 patients. Hypoechoic pattern, round shape, absence of hilum, and cystic necrosis were seen in most of the lymph nodes especially at level 2 and 3 on US and CECT. Matting was more commonly observed than irregular nodal border on US and CECT. Parotid preauricular region involvement was seen in 20.8% of patients on US. Oropharyngeal, retropharyngeal, laryngeal and parotid preauricular region involvement and periorbital edema were seen in 52.4%, 19.1%, 4.8%, 31%, and 9.5% of tularemia patients, respectively. Neck abscess was found in 59.5% of patients on CECT. Suppurative inflammation was the most common finding of FNAC. Tularemia should be considered in the presence of level 2 and 3 lymph nodes with cystic necrosis, matting, absence of calcification, oropharyngeal and retropharyngeal region involvement, and neck abscess, particularly in endemic areas.

  8. High resolution ultrasonography in ankle joint pain: Where does it stand?

    Directory of Open Access Journals (Sweden)

    Mennatallah Hatem Shalaby

    2017-09-01

    Full Text Available Background: The ankle is frequently injured in trauma, overuse syndrome and inflammatory processes. Different imaging modalities assess the ankle, including plain radiography, computed tomography (CT, magnetic resonance imaging (MRI, and ultrasonography (US. Purpose: Our objective is to assess the role of high resolution US as a valuable tool in the depiction of causes of ankle joint pain. Patients and methods: The study included 28 patients presented with ankle pain ranging in age from 17 to 60 years. They were examined by US and findings were correlated with MRI. Results: US was capable to detect various lesions (synovitis, arthritis, plantar fasciitis, tendon and ligamentous lesions. It had a sensitivity of 95.4%, a specificity of 83.3% and an overall accuracy of 92.8%. US had a limited value in detection of avascular necrosis (AVN, bone marrow oedema and fractures. Conclusion: US can be used as a first step diagnostic tool in cases of ankle pain. MRI should be spared to cases with negative or equivocal US findings. Keywords: High resolution ultrasound, Ankle joint pain, Tendons, Ligaments, Synovitis, Arthritis

  9. Radiofrequency ablation of liver cancer: early evaluation of therapeutic response with contrast-enhanced ultrasonography

    International Nuclear Information System (INIS)

    Choi, Dong Gil; Lim, Hyo K.; Lee, Won Jae; Kim, Seung Hoon; Kim, Min Ju; Kim, Seung Kwon; Jang, Kyung Mi; Lee, Ji Yeon; Lim, Jae Hoon

    2004-01-01

    The early assessment of the therapeutic response after percutaneous radiofrequency (RF) ablation is important, in order to correctly decide whether further treatment is necessary. The residual unablated tumor is usually depicted on contrast-enhanced multiphase helical computed tomography (CT) as a focal enhancing structure during the arterial and portal venous phases. Contrast-enhanced color Doppler and power Doppler ultrasonography (US) have also been used to detect residual tumors. Contrast-enhanced gray-scale US, using a harmonic technology which has recently been introduced, allows for the detection of residual tumors after ablation, without any of the blooming or motion artifacts usually seen on contrast-enhanced color or power Doppler US. Based on our experience and reports in the literature, we consider that contrast-enhanced gray-scale harmonic US constitutes a reliable alternative to contrast-enhanced multiphase CT for the early evaluation of the therapeutic response to RF ablation for liver cancer. This technique was also useful in targeting any residual unablated tumors encountered during additional ablation

  10. Ultrasonography with a hand-held device for the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Kameda, Toru; Takahashi, Isao

    2009-01-01

    The purpose of this study was to evaluate the accuracy of ultrasonography (US) with a hand-held device for the diagnosis of acute appendicitis in the emergency room. US with a hand-held device was performed by the first author in 33 patients suspected of having appendicitis in the emergency room. From these 33 patients, 24 who subsequently underwent computed tomography (CT) or surgery were included in this study. The accuracy of US with the hand-held device for the diagnosis of acute appendicitis was evaluated based on the findings of CT or surgery. CT and surgery were performed in 22 and 12 patients, respectively. Final diagnoses were acute appendicitis (n=18), terminal ileitis (n=2), pelvic inflammatory disease (n=2), diverticulitis (n=1), and ureterolithiasis (n=1). The US yielded a sensitivity of 78% and a positive predictive value of 100%. The shortest distance between the abdominal wall and the appendix measured on CT was less than 40 mm in 11 patients. In ten (91%) of the 11 patients US with the hand-held device showed the swollen appendix. US with a hand-held device is potentially useful in the positive identification of acute appendicitis, but further investigation is needed to prove its utility in the routine diagnosis of acute appendicitis. (author)

  11. Unilateral Hemithorax Opacification on Chest Radiograph : Comparison of Diagnostic Accuracy of Chest Ultrasonography with CT

    Energy Technology Data Exchange (ETDEWEB)

    Namkung, Sook; Lee, Kyung Soo; Kwon, O Jung [Samsung Medical Center, Seoul (Korea, Republic of); Chung, Seung Eun [Sangkye Paek Hospital, Seoul (Korea, Republic of)

    1996-12-15

    To compare the diagnostic accuracy of chest ultrasonography (US) with computed tomography (CT) inpatients with opacification more than one third of unilateral hemithorax on chest radiograph (CXR). Chest US and CT scans from 41 consecutive patients with opacification more than one third of unilateral hemithorax on CXR were prospectively evaluated by two independent radiologists. Each radiologist recorded 1) the nature of pleural effusion (transudate vs. exudate), 2) presence or absence of pulmonary lesion, 3) the characteristic of pulmonary lesion (consolidation or atelectasis and tumor), and 4) presence of solid pleural tumor. The diagnostic accuracy of chest US was compared with CT scan in patients with pleural, pulmonary or other disease. In 32 patients with pleural effusion, differentiation between transudate and exudate was feasible in 27 (84%) patients with US and 26 (81%) patients with CT. In 32 patients with pulmonary and other pleural diseases, sensitivity, specificity and accuracy of US in lesion detection were 86%, 75% and 83% respectively when CT was regarded as a diagnostic gold standard. The diagnostic accuracy of chest US is comparable to CT in patients with hemithorax opacification on CXR

  12. Unilateral Hemithorax Opacification on Chest Radiograph : Comparison of Diagnostic Accuracy of Chest Ultrasonography with CT

    International Nuclear Information System (INIS)

    Namkung, Sook; Lee, Kyung Soo; Kwon, O Jung; Chung, Seung Eun

    1996-01-01

    To compare the diagnostic accuracy of chest ultrasonography (US) with computed tomography (CT) inpatients with opacification more than one third of unilateral hemithorax on chest radiograph (CXR). Chest US and CT scans from 41 consecutive patients with opacification more than one third of unilateral hemithorax on CXR were prospectively evaluated by two independent radiologists. Each radiologist recorded 1) the nature of pleural effusion (transudate vs. exudate), 2) presence or absence of pulmonary lesion, 3) the characteristic of pulmonary lesion (consolidation or atelectasis and tumor), and 4) presence of solid pleural tumor. The diagnostic accuracy of chest US was compared with CT scan in patients with pleural, pulmonary or other disease. In 32 patients with pleural effusion, differentiation between transudate and exudate was feasible in 27 (84%) patients with US and 26 (81%) patients with CT. In 32 patients with pulmonary and other pleural diseases, sensitivity, specificity and accuracy of US in lesion detection were 86%, 75% and 83% respectively when CT was regarded as a diagnostic gold standard. The diagnostic accuracy of chest US is comparable to CT in patients with hemithorax opacification on CXR

  13. [Ultrasonography-guided therapeutic procedures in the neck region].

    Science.gov (United States)

    Brzac, Hrvojka Tomić

    2009-12-01

    Minimally invasive therapeutic procedures in medicine have become very popular because of the reduced risk compared to classic surgical treatment, speed of recovery, little or no side effects, and frequently lower cost. One of these methods is ultrasonography-guided percutaneous injection of 95% ethanol (PEIT, percutaneous ethanol injection therapy), which is especially suitable for the neck region. Other methods like laser photocoagulation (ILP) or radiofrequency ablation (RFA) are more aggressive and expensive. The procedure of sterile 95% ethanol injecting is performed on an outpatient basis, without preparation. A specific amount of alcohol is injected into the lesion using a thin spinal needle, under ultrasonography guidance. The amount of alcohol depends on the size of the lesion. Complications are rare and the procedure can be repeated several times. PEIT is used in the treatment of parathyroid glands, especially secondary hyperparathyroidism, thyroid nodules (toxic adenoma, goiters and cysts), other cysts on the neck, and cervical metastases of thyroid cancer. Direct ethanol injection into the tissue causes cellular dehydration and protein denaturation, followed by the development of necrosis, fibrosis, and thrombosis of the small blood vessels. In this way, reduction or disappearance of the nodes can be achieved, along with functional normalization (for parathyroid glands and toxic adenoma), with longer or shorter disease remission or complete recovery. Today, PEIT is mostly used in dialyzed patients with secondary hyperparathyroidism. The treatment gives best results in combination with vitamin D analogs, if 1-2 parathyroid glands are enlarged, and for residual parathyroid gland after parathyroidectomy. A success rate of 50%-70% has been reported, depending on the number of enlarged parathyroid glands. Therapeutic effect is manifested in the size reduction or complete fibrozation of the gland, reduction or disappearance of vascularization, and a decrease

  14. Use of Bedside Compression Ultrasonography for Diagnosis of Deep Venous Thrombosis

    Directory of Open Access Journals (Sweden)

    Mohamad Moussa

    2017-07-01

    Full Text Available History of present illness: A 70-year-old female with a history of breast cancer and smoking for 50 years presented to the emergency department with left-lower extremity pain and swelling for two days. The patient denied recent long-distance travel, history of hypercoagulable disorder, or recent surgery. Physical examination revealed a warm, erythematous, 3+ edematous left-lower extremity with mild tenderness extending into the proximal thigh. Her D-dimer level was 2307ng/mL and vital signs were significant for a heart rate of 110bpm, oxygen saturation of 90% on 2 liters of oxygen, and blood pressure of 153/102. Significant findings: As shown in the still image of the performed ultrasound, a transverse view of the proximal-thigh revealed a visible thrombus (green shading occluding the lumen of the left common femoral vein (blue ring, which was non-compressible when direct pressure was applied to the probe. Also visible is a patent and compressible branch of the common femoral vein (purple ring and the femoral artery (red ring, highlighted by its thick vessel wall and pulsatile motion. Discussion: Deep venous thrombosis (DVT affects 1 per 1,000 individuals each year and may lead to complications such as recurrent DVT, pulmonary embolism, and death.1 The utilization of bedside compression ultrasonography allows for rapid diagnosis of DVT and has virtually replaced other diagnostic methods due to its non-invasive and inexpensive nature. When performing compression ultrasonography, the patient should be positioned to maximize distention of the leg veins. The extremity in question should be flexed at the knee and externally rotated at the hip (this fully exposes of the common, superficial, and deep femoral veins as well as the popliteal fossa and the head of the bed elevated at a 30-45 degree angle.2 In patients with an elevated D-dimer and low-to-moderate clinical probability, negative compression imaging of a single proximal location of the femoral

  15. Predictive value of excretory urography, ultrasonography, computerized tomography, and liver and bone scan in the staging of bilharzial bladder cancer in Saudi Arabia

    International Nuclear Information System (INIS)

    Hanash, K.A.; Bissada, N.K.; Abla, A.; Esmail, D.; Dowling, A.

    1984-01-01

    The role of ultrasonography, computed tomography (CT), and radioisotopic scanning in the staging of bilharzial bladder cancer has not been reported previously. Forty patients with invasive bladder cancer seen at the King Faisal Specialist Hospital and Research Centre between January 1978 and June 1981 underwent complete preoperative workup for staging of their tumors prior to radical cystectomy. The preoperative radiologic investigations included excretory urography (IVP), ultrasonography (US), CT of the pelvis, and liver and bone scans. The results of these investigations were compared with the operative and pathologic staging. Ninety-three percent of the patients with bilharzial cancer had evidence of ureteric obstruction on IVP compared with 22% of the nonbilharzial cancer patients. The presence of ureteric obstruction in these patients did not correlate with the stage of the disease with 83% of the patients with superficial tumors (T1 and T2) having hydroureteronephrosis. Ultrasonography and CT had an 83% accuracy in the staging of superficial tumors. Stage T3 tumors were understaged in 14% of the cases. Ultrasonography did not differentiate Stages T3 and T4 tumors while CT scan differentiated these two stages in 57% of the cases. Bone scan failed to reveal evidence of metastatic disease in any of the bilharzial cancer patients. Liver scan was suspicious for liver metastases in two patients with bilharzial cancers in whom open liver biopsy revealed only hepatic bilharziasis. Of all the radiographic studies, US or preferably CT scan seem to be of some value in the staging of bilharzial tumors localized to the bladder. Bone and liver scans are probably of no cost effective benefit

  16. Discrepancy between ultrasonography and hysteroscopy and histology of endometrium in postmenopausal breast cancer patients using tamoxifen

    NARCIS (Netherlands)

    Mourits, MJE; Van der Zee, AGJ; Willemse, PHB; Ten Hoor, KA; Hollema, H; De Vries, EGE

    Background. The increased risk of endometrial carcinoma following the use of tamoxifen has stimulated studies on endometrial diagnostic screening methods. In tamoxifen users the endometrial thickening observed with transvaginal ultrasonography (TVU) frequently cannot be confirmed by hysteroscopy or

  17. Comparison of Radiography and Ultrasonography for Diagnosis of Diaphragmatic Hernia in Bovines

    Directory of Open Access Journals (Sweden)

    Hakim Athar

    2010-01-01

    Full Text Available The present study was conducted on 101 animals suffering from thoracoabdominal disorders; out of which twenty seven animals (twenty six buffaloes and one cow were diagnosed with diaphragmatic hernia based on clinical signs, radiography, ultrasonography, and left flank laparorumenotomy. Radiography alone confirmed diaphragmatic hernia in 18 cases (66.67% with a sac-like structure cranial to the diaphragm. In 15 animals the sac contained metallic densities while in three cases a sac-like structure with no metallic densities was present. Ultrasonography was helpful in confirming diaphragmatic hernia in 23 cases (85.18% and ultrasonographically reticular motility was evident at the level of 4th/5th intercostal space in all the animals. B+M mode ultrasonography was used for the first time for diagnosis of diaphragmatic hernia in bovines and the results suggested that ultrasonography was a reliable diagnostic modality for diaphragmatic hernia in bovines.

  18. Ultrasonography of pediatric urogenital emergencies: review of classic and new techniques

    Directory of Open Access Journals (Sweden)

    Masahiro Kitami

    2017-07-01

    Full Text Available Urogenital emergencies are fairly common in the pediatric population, and a timely and correct diagnosis is necessary to avoid possible future infertility. In this field, ultrasonography is essential, as it has the advantages of being radiation-free and readily accessible. In particular, a high-frequency transducer allows precise evaluation of the morphology and vascularity of the scrotum, which is on the surface of the body. Beyond conventional techniques, new advanced imaging techniques have been developed, including elastography and contrast-enhanced ultrasonography. However, several pitfalls remain in the diagnosis of urogenital diseases using ultrasonography. Thus, accurate knowledge and sufficient experience with the technique are essential for making a correct diagnosis. This review provides an overview of pediatric urogenital emergency pathologies and recent ultrasonography techniques.

  19. Reliability of ultrasonography in detecting shoulder disease in patients with rheumatoid arthritis.

    LENUS (Irish Health Repository)

    Bruyn, G A W

    2009-03-01

    To assess the intra and interobserver reproducibility of musculoskeletal ultrasonography (US) among rheumatologists in detecting destructive and inflammatory shoulder abnormalities in patients with rheumatoid arthritis (RA) and to determine the overall agreement between US and MRI.

  20. Ultrasonography of pediatric urogenital emergencies: review of classic and new techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kitami, Masahiro [Dept. of Diagnostic Radiology, Tohoku University Graduate School of Medicine, Sendai (Japan)

    2017-07-15

    Urogenital emergencies are fairly common in the pediatric population, and a timely and correct diagnosis is necessary to avoid possible future infertility. In this field, ultrasonography is essential, as it has the advantages of being radiation-free and readily accessible. In particular, a high-frequency transducer allows precise evaluation of the morphology and vascularity of the scrotum, which is on the surface of the body. Beyond conventional techniques, new advanced imaging techniques have been developed, including elastography and contrast-enhanced ultrasonography. However, several pitfalls remain in the diagnosis of urogenital diseases using ultrasonography. Thus, accurate knowledge and sufficient experience with the technique are essential for making a correct diagnosis. This review provides an overview of pediatric urogenital emergency pathologies and recent ultrasonography techniques.

  1. Imaging of juvenile spondyloarthritis. Part II: Ultrasonography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Iwona Sudoł-Szopińska

    2017-09-01

    Full Text Available Juvenile spondyloarthropathies are mainly manifested by symptoms of peripheral arthritis and enthesitis. Early involvement of sacroiliac joints and spine is exceptionally rare in children; this usually happens in adulthood. Conventional radiographs visualize late inflammatory lesions. Early diagnosis is possible with the use of ultrasonography and magnetic resonance imaging. The first part of the article presented classifications and radiographic presentation of juvenile spondyloarthropathies. This part discusses changes seen on ultrasonography and magnetic resonance imaging. In patients with juvenile spondyloarthropathies, these examinations are conducted to diagnose inflammatory lesions in peripheral joints, tendon sheaths, tendons and bursae. Moreover, magnetic resonance also shows subchondral bone marrow edema, which is considered an early sign of inflammation. Ultrasonography and magnetic resonance imaging do not show specific lesions for any rheumatic disease. Nevertheless, they are conducted for early diagnosis, treatment monitoring and identifying complications. This article presents a spectrum of inflammatory changes and discusses the diagnostic value of ultrasonography and magnetic resonance imaging.

  2. Reliability of ultrasonography in detecting shoulder disease in patients with rheumatoid arthritis

    NARCIS (Netherlands)

    Bruyn, G. A. W.; Naredo, E.; Moeller, I.; Moragues, C.; Garrido, J.; de Bock, G. H.; d'Agostino, M-A; Filippucci, E.; Iagnocco, A.; Backhaus, M.; Swen, W. A. A.; Balint, P.; Pineda, C.; Milutinovic, S.; Kane, D.; Kaeley, G.; Narvaez, F. J.; Wakefield, R. J.; Narvaez, J. A.; de Augustin, J.; Schmidt, W. A.; Moller, I.; Swen, N.; de Agustin, J.

    Objective: To assess the intra and interobserver reproducibility of musculoskeletal ultrasonography ( US) among rheumatologists in detecting destructive and inflammatory shoulder abnormalities in patients with rheumatoid arthritis ( RA) and to determine the overall agreement between US and MRI.

  3. Solitary extramedullary plasmacytomas of thyroid in Hashimoto's thyroiditis: Mimicking benign cystic nodule on ultrasonography

    International Nuclear Information System (INIS)

    Kwon, Yohan; Kim, Soo Jin; Hur, Joon Ho; Park, Sung Hee; Lee, Sun Jin; Lee, Tae Jin

    2013-01-01

    Solitary extramedullary plasmacytoma (SEP) of the thyroid is uncommon and mostly occur in patients with a Hashimoto's thyroiditis (82%). We present a case on SEP of thyroid in Hashimoto's thyroiditis, which mimics growing benign cystic masses on serial ultrasonography.

  4. An economic evaluation of second-trimester genetic ultrasonography for prenatal detection of down syndrome.

    Science.gov (United States)

    Vintzileos, A M; Ananth, C V; Fisher, A J; Smulian, J C; Day-Salvatore, D; Beazoglou, T; Knuppel, R A

    1998-11-01

    The objective of this study was to perform an economic evaluation of second-trimester genetic ultrasonography for prenatal detection of Down syndrome. More specifically, we sought to determine the following: (1) the diagnostic accuracy requirements (from the cost-benefit point of view) of genetic ultrasonography versus genetic amniocentesis for women at increased risk for fetal Down syndrome and (2) the possible economic impact of second-trimester genetic ultrasonography for the US population on the basis of the ultrasonographic accuracies reported in previously published studies. A cost-benefit equation was developed from the hypothesis that the cost of universal genetic amniocentesis of patients at increased risk for carrying a fetus with Down syndrome should be at least equal to the cost of universal genetic ultrasonography with amniocentesis used only for those with abnormal ultrasonographic results. The main components of the equation included the diagnostic accuracy of genetic ultrasonography (sensitivity and specificity for detecting Down syndrome), the costs of the amniocentesis package and genetic ultrasonography, and the lifetime cost of Down syndrome cases not detected by the genetic ultrasonography. After appropriate manipulation of the equation a graph was constructed, representing the balance between sensitivity and false-positive rate of genetic ultrasonography; this was used to examine the accuracy of previously published studies from the cost-benefit point of view. Sensitivity analyses included individual risks for Down syndrome ranging from 1:261 (risk of a 35-year-old at 18 weeks' gestation) to 1:44 (risk of a 44-year-old at 18 weeks' gestation). This economic evaluation was conducted from the societal perspective. Genetic ultrasonography was found to be economically beneficial only if the overall sensitivity for detecting Down syndrome was >74%. Even then, the cost-benefit ratio depended on the corresponding false-positive rate. Of the 7

  5. Effect of Ultrasonography on Student Learning of Shoulder Anatomy and Landmarks.

    Science.gov (United States)

    de Vries, Kristen D; Brown, Rebecca; Mazzie, Joseph; Jung, Min-Kyung; Yao, Sheldon C; Terzella, Michael J

    2018-01-01

    Ultrasonography is becoming more common in clinical use, and it has been shown to have promising results when introduced into medical school curricula. To determine whether the use of ultrasonography as an educational supplement can improve osteopathic medical students' confidence and ability to locate 4 specific shoulder anatomical landmarks: the coracoid process, the transverse process of T1, the long head of the biceps within the bicipital groove, and the supraspinatus tendon. In this randomized controlled study, first-year osteopathic medical students aged 18 years or older were recruited and randomly assigned to a group with exposure (ultrasonography group) or without exposure (control group) to an ultrasonography machine. First, a survey was administered to measure students' baseline knowledge of shoulder anatomy, confidence in palpation skills, and opinion on anatomical landmark identification teaching methods. Next, students were shown presentations on shoulder anatomy and allowed to practice locating and palpating the specified landmarks. Students in the ultrasonography group were also given instruction on the use of ultrasonography. All students were asked to locate each of the 4 specified anatomical landmarks and then given a follow-up survey. A Mann Whitney U test was used to compare the confidence of the students before and after the intervention. A secondary analysis was performed to compare the degree of deviance from the correct position of the specified anatomical landmark between the ultrasonography and control groups. P values less than .05 were considered statistically significant. Sixty-four students participated. Compared with the control group, students in the ultrasonography group had a greater increase in confidence after the session in their ability to locate the coracoid process, bicipital tendon, and supraspinatus tendon (P=.022, P=.029, P=.44, respectively). Students in the ultrasonography group were also able to more accurately palpate

  6. HIGH-RESOLUTION ULTRASONOGRAPHY OF SHOULDER FOR ROTATOR CUFF TEAR: CORRELATION WITH ARTHROSCOPIC FINDINGS

    OpenAIRE

    Vishnumurthy H. Y; Jagdeesh K. S; Anand K; Ranoji Mane; Sanath G. Kamte; Fathima Zohra; Banerji B. H; Sathish Servegar

    2016-01-01

    INTRODUCTION Rotator cuff disease is the most common cause of shoulder pain. Ultrasonography being non-invasive, widely available, more cost-effective method and is the first choice in imaging of rotator cuff tears. Arthroscopy of shoulder is considered as the gold standard for diagnosis of rotator cuff tears. Objective of this study was to compare the diagnostic accuracy of high-resolution ultrasonography of shoulder for rotator cuff tears with arthroscopy of shoulder. METHODS...

  7. Two cases of posterior scleritis and findings of computerized tomography and ultrasonography

    International Nuclear Information System (INIS)

    Ohara, Takakazu; Uji, Yukitaka; Fujioka, Chieko; Mori, Kazuma

    1982-01-01

    Two cases of unilateral posterior scleritis, seen in 56-year-old and 68-year-old females, are reported. Computerized tomography showed characteristic findings, as follows: 1) Thickening of the posterior sclera and surrounding tissue. 2) Irregularity of the posterior wall of the eyeball. 3) Increased radiographic density in the posterior wall of the eyeball. Ultrasonography also suggested thickening of the posterior sclera. Computerized tomography and ultrasonography are considered useful in the diagnosis of posterior scleritis. (author)

  8. Comparison of ultrasonography with radiography for the detection of cervical esophageal foreign body

    OpenAIRE

    Reza Pourrashidi; Shervin Sharifkashani; Hashem Sharifian; Habib Mazaher; Peyman Salamati; Batool Ghorbani yekta

    2013-01-01

    Background: Detection of retained foreign bodies remains a significant problem in the emergency department. Foreign bodies can go undetected causing infectious complications ultrasonography is too inaccessible and expensive. The purpose of this study is comparison of ultrasonography with radiography for the detection of cervical esophageal foreign bodiesMethods: This cross-sectional study evaluated 58 patients referred with suspected upper esophageal foreign body in the Emergency Department, ...

  9. Positioning Ultrasonography Into Clinical Practice for the Management of Crohn’s Disease

    Science.gov (United States)

    Zorzi, Francesca; Lolli, Elisabetta; Pallone, Francesco

    2015-01-01

    Over the past few years, the technical evolution of ultrasound equipment, the use of oral and intravenous contrast agents, and an increase in the expertise of operators have enhanced the role that ultrasonography plays in the assessment of the gastrointestinal tract. For patients with chronic inflammatory conditions, particularly Crohn’s disease, it has been suggested that ultrasonography can be used not only for diagnostic purposes but also in disease management. These developments are reviewed in this article. PMID:27118932

  10. Role of ultrasonography in detecting mammographically occult breast carcinoma in women with dense breasts.

    Science.gov (United States)

    Corsetti, V; Ferrari, A; Ghirardi, M; Bergonzini, R; Bellarosa, S; Angelini, O; Bani, C; Ciatto, S

    2006-04-01

    The purpose of this study was to assess the usefulness of routine ultrasonography in women with negative mammography and dense breasts [Breast Imaging Reporting and Data System (BIRADS D3-4)]. We applied a protocol involving routine ultrasonography in a consecutive series of subjects with negative mammography and dense breasts. After evaluation by internal and external reviewers of cancers detected by ultrasonography performed to confirm negative mammography, we determined the additional cancer detection rate of ultrasonography and the cost of the protocol. Out of 17,883 total mammographies, 167 cancers were diagnosed (detection rate: 0.93%). Out of 257 suspicious mammographies, 138 cancers were detected. Out of 17,626 negative mammographies, 6,449 (36.5%) were classified as "dense breast" and underwent ultrasonography: 29 cancers were detected (detection rate: 0.44%, or 17.3% of total cancers). Out of 25 cancer cases reviewed, negative mammography and asymptomatic status was confirmed in 15 (detection rate 0.23%, or 8.9% of total cancers). The cancer detection rate was 0.11%, 0.22%, 0.32% and 0.14% for age groups 59, respectively. The cost per additional carcinoma detected by ultrasonography alone was euro 25,847.85 whereas that per examined woman was euro 21.68. The study confirms the possibility that ultrasonography can detect mammographically occult breast carcinoma in dense breasts. The evidence is insufficient to recommend this policy in routine screening practice but suggests that, at least in current clinical practice, adding ultrasonography in dense breasts may be useful despite the substantial costs.

  11. The value of fetal ultrasonography and magnetic resonance imaging in the assessment of diaphragmatic hernias

    International Nuclear Information System (INIS)

    Amim, Bruno; Guerra, Fernando; Marchiori, Edson; Gasparetto, Emerson Leandro

    2008-01-01

    To demonstrate the relevance of ultrasonography and magnetic resonance imaging findings in the prenatal characterization and prognostic evaluation in cases of congenital diaphragmatic hernia. Materials And Methods: Fourteen pregnant women (mean gestational age = 28.7 weeks) who had undergone ultrasonography for suspicion of fetuses with congenital diaphragmatic hernia were assessed by means of magnetic resonance imaging on a 1.5 tesla equipment, following the standard protocol. Two radiologists evaluated the images and the findings were defined by consensus. Results: Twelve fetuses had left diaphragmatic hernia and two, right diaphragmatic hernia. Ultrasonography showed the fetal liver inside the thorax of five fetuses (three with left diaphragmatic hernia, and two with right diaphragmatic hernia) and magnetic resonance imaging in eight fetuses (six with left diaphragmatic hernia, and two with right diaphragmatic hernia). Stomach and small bowel loop herniation was observed in all of the fetuses with left diaphragmatic hernia (n = 12) at both magnetic resonance imaging and ultrasonography. Eight fetuses (seven with left diaphragmatic hernia and one with right diaphragmatic hernia) survived after surgical treatment. Conclusion: Ultrasonography and magnetic resonance imaging are complementary imaging methods in the evaluation of congenital diaphragmatic hernia. Magnetic resonance imaging is a helpful diagnostic method complementary to ultrasonography for evaluation of the fetal liver positioning, considering its relevance as a prognostic factor in cases of congenital diaphragmatic hernia. (author)

  12. Hydrodynamic study of syringomyelia by MRI and intraoperative ultrasonography

    International Nuclear Information System (INIS)

    Moritake, Kouzo; Takaya, Mikio; Minamikawa, Jun; Ishikawa, Masatsune; Kikuchi, Haruhiko; Minami, Shunsuke

    1989-01-01

    Syringomyelic cavities were studied with magnetic resonance imaging (MRI) in eleven patients with special reference to the hemodynamic contribution to the pathogenesis of syringomyelia. They were also studied intraoperatively with ultrasonography (USG) in five patients. Syrinx cavities combined with lumbosacral lipomyelomeningocele or with spinal stenosis did not present a flow-void phenomenon reflecting pulsatile movements of syrinx fluid. On serial MRI study in those the patients, enlargement of the syrinx cavity was not observed. Syrinx cavities occupying the caudal part of the spinal cord did not develop either. These cases were not treated surgically but followed conservatively. On the other hand, the flow-void sign in the syrinx cavities was present on MRI in patients who also had Chiari type I or type II malformations. They were treated with a syringo-subarachnoid shunt. In these cases, intraoperative USG disclosed marked fluctuation of syrinx cavity size synchronous with the motions of pulmonary ventilation. In all of them, clinical signs and symptoms improved postoperatively to various degrees. These results suggest that both the flow-void sign in the syrinx cavity on MRI and marked fluctaution of cavity size on intraoperative USG are indications for the shunt operation and support William's revised theory (1987). Fluctuation of cystic cavity size synchronous with ventilation suggests that venous pressure in the spinal subarachnoid space contributes to the pathogenesis of syringomyelic cavities. Further analysis of the fluctuation of cystic cavities by video monitoring will provide further information on the etiology and other clinical problems of syringomyelia. (author)

  13. Transcranial Doppler ultrasonography predicts cardiovascular events after TIA

    International Nuclear Information System (INIS)

    Holzer, Katrin; Sadikovic, Suwad; Esposito, Lorena; Bockelbrink, Angelina; Sander, Dirk; Hemmer, Bernhard; Poppert, Holger

    2009-01-01

    Transient ischemic attack (TIA) patients are at high vascular risk. We assessed the value of extracranial (ECD) and transcranial (TCD) Doppler and duplex ultrasonography to predict clinical outcome after TIA. 176 consecutive TIA patients admitted to the Stroke Unit were recruited in the study. All patients received diffusion-weighted imaging, standardized ECD and TCD. At a median follow-up of 27 months, new vascular events were recorded. 22 (13.8%) patients experienced an ischemic stroke or TIA, 5 (3.1%) a myocardial infarction or acute coronary syndrome, and 5 (3.1%) underwent arterial revascularization. ECD revealed extracranial ≥ 50% stenosis or occlusions in 34 (19.3%) patients, TCD showed intracranial stenosis in 15 (9.2%) and collateral flow patterns due to extracranial stenosis in 5 (3.1%) cases. Multivariate analysis identified these abnormal ECD and TCD findings as predictors of new cerebral ischemic events (ECD: hazard ratio (HR) 4.30, 95% confidence interval (CI) 1.75 to 10.57, P = 0.01; TCD: HR 4.73, 95% CI 1.86 to 12.04, P = 0.01). Abnormal TCD findings were also predictive of cardiovascular ischemic events (HR 18.51, 95% CI 3.49 to 98.24, P = 0.001). TIA patients with abnormal TCD findings are at high risk to develop further cerebral and cardiovascular ischemic events

  14. Ultrasonography of Skin Changes in Legs with Chronic Venous Disease.

    Science.gov (United States)

    Caggiati, A

    2016-10-01

    In daily practice, ultrasonography (US) is used only to designate the location and pattern of venous lesions. Skin US is not performed between routine venous investigations. Skin morphology is evaluated by the same probes used for routine Duplex evaluation of superficial veins. US findings from evident skin lesions are comparatively evaluated with those from the surrounding apparently normal skin and from the contralateral leg. Inflammation and dermal edema can be found in the apparently normal skin of C2 legs. Swollen legs show thickening of the subcutaneous layer as a result of diffuse soaking or anechoic cavities, with or without dermal edema. Chronic hypodermitis is characterized by inflammatory edema in initial phases, and by liposclerosis in advanced cases. Recrudescence of inflammation provokes focal rarefactions of the subcutaneous layer, possibly related to ulcer opening. In legs with venous disorders, sonography refines clinical evaluation of the skin and may reveal changes not highlighted by inspection. Some of these changes could require further investigation because they have not yet been explained or described. Skin sonography should improve knowledge of the natural history of skin changes, as well as contribute to a better grading of venous diseases severity In particular, US evidence of cutaneous and subcutaneous changes in C2 legs should be considered to stratify the treatment in C2 legs, by identifying those in which varicose veins are not simply a cosmetic problem. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Deep venous thrombus characterization: ultrasonography, elastography and scattering operator

    Directory of Open Access Journals (Sweden)

    Thibaud Berthomier

    2017-04-01

    Full Text Available A thrombus or a blood clot is the result of blood coagulation which is a natural process to prevent bleeding. An inappropriate formation of a thrombus in a deep vein is known as Deep Venous Thrombosis (DVT. The main complication of a DVT is a Pulmonary Embolism (PE which occurs when a thrombus breaks loose and travels to the lungs. DVT, PE, or both are also known as Venous thromboembolism (VTE. It affects an estimated 300,000–600,000 Individuals just in the United States per year and can cause considerable morbidity and mortality. This multifactorial disease related to advanced age, immobility, surgery or obesity is an important public health issue. Our project is looking to link the VTE epidemiology (risk factors, patient history, PE to the thrombus structure. To reach our goals, we are collecting ultrasonography (echogenicity and elastography (stiffness of human thrombus. This manuscript describes our approach to create and preprocess a database using Toshiba Aplio 500. Our approaches to characterize the thrombus structure with ultrasound images are also described. The feature extraction is made with the scattering operator. Obtained features are then reduced using Principal Component Analysis and are analyzed to evaluate our approach.

  16. Ultrasonography findings and tumour quantification in patients with pseudomyxoma peritonei

    International Nuclear Information System (INIS)

    Krause, J.; Bergman, A.; Graf, W.; Nilsson, A.; Mahteme, H.

    2012-01-01

    Pseudomyxoma peritonei (PMP) is a disease with various clinical presentations and the diagnostic value of ultrasonography (US) is under investigated. The purpose of this study was to identify the most common US finding in PMP and to investigate US sensitivity, specificity, positive and negative predictive value in quantifying tumour burden in different abdomino-pelvic regions in PMP patients. Between February 2006 and December 2008, 54 patients were treated with cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) due to PMP. The results from preoperative US examination with and without intravenously administrated contrast (SonoVue) were compared to surgical findings. The mean US peritoneal cancer index (PCI) was 6 (range 0–25) and the surgical PCI was 18 (range 3–27) p < 0.0001. The histo-pathological subtypes did not influence the US findings. Ascites, bowel loops adhesions and omental cake were mostly visualised correctly by US. The sensitivity of US in quantification of tumour nodules was 91.5% (range 74–100%) and specificity was 33.8% (range 18–55%). The positive predictive value of US examination in PMP was 22% (range 11–44%) and the negative predictive value was 93% (range 77–100%). US can detect the most common PMP findings (ascites and omental cake). The sensitivity of US to quantify PMP tumour burden in different abdominio-pelvic region was relatively high, however, this imaging tool had low specificity.

  17. Availability of ultrasonography in health examination of atomic bomb survivors

    International Nuclear Information System (INIS)

    Kato, Masafumi; Mito, Kazuyo; Ishibashi, Shinzo; Takayama, Sadamatsu; Ito, Chikako

    1989-01-01

    A total of 1424 A-bomb survivors, consisting of 596 men and 827 women, participated in the health screening during the period from August 1985 through March 1988. Abnormal findings of ultrasonography were observed in 64% for men and 53% for women. According to age groups, the incidence of abnormal findings tended to increase with aging in men. In women, it was independent of aging. The most common abnormal finding was billiary calculus (13%), followed by renal cyst, splenomegaly, hepatomegaly, and liver disturbance. Suspected hepatic tumor, hepatomegaly, liver disturbance, fatty liver, and liver cirrhosis were more frequent in men than women. The incidence of billiary or gallbladder calculus was significantly higher in women than men. Among 56 survivors (13%) with suspected malignancy, it was confirmed in 25 survivors (19 with primary or metastatic liver carcinoma, 3 with renal cell carcinoma, 2 with cholangiocarcinoma, and one with pancreatic carcinoma). Of 9 hepatoma patients, 8 had an increased alpha-fetoprotein. Hematologic findings were normal in all of the patients with renal cell carcinoma. (N.K.)

  18. Fetal central nervous system anomalies: fast MRI vs ultrasonography

    International Nuclear Information System (INIS)

    Yang Wenzhong; Xia Liming; Yang Minjie; Feng Dingyi; Hu Junwu; Zou Mingli; Wang Chengyuan; Chen Xinlin; Yang Xiaohong

    2006-01-01

    Objective: To evaluate the ability of fast MRI to detect fetal central nervous system (CNS) anomalies and to compare its performance with that of prenatal ultrasonography (US). Methods Forty-eight pregnant women were detected by conventional prenatal US and MRI. Twenty-two fetuses with CNS anomalies were conformed by autopsy and follow-up. The MR and US appearances of fetal CNS structure were compared to each other and to that of autopsy. Results: A total of 26 CNS anomalies were identified by autopsy (n=17) and follow-up (n=9) including anencephaly (n=6), rachischisis (n=2), encephalocele (n=3), congenital hydrocephalus (n=7), alobar holoprosencephaly (n=1), porencephalia (n=3), arachnoid cyst (n=2) and choroids plexus cyst (n=2). US diagnosed 24 CNS anomalies, the correct diagnostic rate was 92.3%, the false-positive rate was 3.8%, the missed-diagnostic rate was 3.8%. MRI diagnosed 23 CNS anomalies, the correct-diagnostic rate was 88.5%, the false-positive rate was 3.8% ,the missed-diagnostic rate was 7.7%. There was no difference between US and MRI (P>0.05), but MRI have larger FOV, higher tissues resolution, and can demonstrate gray-white matter in detail. Conclusions: MR imaging has a similar sensitivity to that of US in the detection of fetal CNS anomalies. (authors)

  19. Ultrasonography and arthrography in rotator cuff lesions: algorithmic approach

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eui Jong; Ryu, Kyung Nam; Lee, Sun Wha; Lim, Jae Hoon; Rhee, Yong Girl [Kyung Hee University Hospital, Seoul (Korea, Republic of); Yu, Pil Mun [Dankuk University College of Medicine, Chenona (Korea, Republic of)

    1992-11-15

    Twenty-six patients with chief complaint of shoulder pain who underwent both ultrasonographic examination and arthrography of the shoulder were analyzed. Ten out of 12 cases with clinical impression of frozen shoulder, showed normal findings on the ultrasonographic examination of the shoulder. Among these ten cases, nine cases showed adhesive capsulitis and one case showed rotator cuff tear on arthrography. Among six cases with the clinical impression of rotator cuff tear, five cases showed rotator cuff tear and one case showed combined calcific tendinitis and adhesive capsulitis on ultrasonographic examination. In arthrography, four cases of rotator cuff tear, one case of calcific tendinitis and biceps tendinitis and one case of normal finding were diagnosed. For the remaining eight cases in the ultrasonographic examination, normal finding or biceps tendinitis were found and for the remaining of the cases in arthrography adhesive capsulitis were found. With the above results, we recommend that the shoulder ultrasonography as the first line diagnostic modality for a patient with chief complaint of shoulder pain.

  20. Ultrasonography and arthrography in rotator cuff lesions: algorithmic approach

    International Nuclear Information System (INIS)

    Kim, Eui Jong; Ryu, Kyung Nam; Lee, Sun Wha; Lim, Jae Hoon; Rhee, Yong Girl; Yu, Pil Mun

    1992-01-01

    Twenty-six patients with chief complaint of shoulder pain who underwent both ultrasonographic examination and arthrography of the shoulder were analyzed. Ten out of 12 cases with clinical impression of frozen shoulder, showed normal findings on the ultrasonographic examination of the shoulder. Among these ten cases, nine cases showed adhesive capsulitis and one case showed rotator cuff tear on arthrography. Among six cases with the clinical impression of rotator cuff tear, five cases showed rotator cuff tear and one case showed combined calcific tendinitis and adhesive capsulitis on ultrasonographic examination. In arthrography, four cases of rotator cuff tear, one case of calcific tendinitis and biceps tendinitis and one case of normal finding were diagnosed. For the remaining eight cases in the ultrasonographic examination, normal finding or biceps tendinitis were found and for the remaining of the cases in arthrography adhesive capsulitis were found. With the above results, we recommend that the shoulder ultrasonography as the first line diagnostic modality for a patient with chief complaint of shoulder pain

  1. Musculoskeletal ultrasonography delineates ankle symptoms in rheumatoid arthritis.

    Science.gov (United States)

    Toyota, Yukihiro; Tamura, Maasa; Kirino, Yohei; Sugiyama, Yumiko; Tsuchida, Naomi; Kunishita, Yosuke; Kishimoto, Daiga; Kamiyama, Reikou; Miura, Yasushi; Minegishi, Kaoru; Yoshimi, Ryusuke; Ueda, Atsuhisa; Nakajima, Hideaki

    2017-05-01

    To clarify the use of musculoskeletal ultrasonography (US) of ankle joints in rheumatoid arthritis (RA). Consecutive RA patients with or without ankle symptoms participated in the study. The US, clinical examination (CE), and patients' visual analog scale for pain (pVAS) for ankles were assessed. Prevalence of tibiotalar joint synovitis and tenosynovitis were assessed by grayscale (GS) and power Doppler (PD) US using a semi-quantitative grading (0-3). The positive US and CE findings were defined as GS score ≥2 and/or PD score ≥1, and joint swelling and/or tenderness, respectively. Multivariate analysis with the generalized linear mixed model was performed by assigning ankle pVAS as a dependent variable. Among a total of 120 ankles from 60 RA patients, positive ankle US findings were found in 21 (35.0%) patients. The concordance rate of CE and US was moderate (kappa 0.57). Of the 88 CE negative ankles, US detected positive findings in 9 (10.2%) joints. Multivariate analysis revealed that ankle US, clinical disease activity index, and foot Health Assessment Questionnaire, but not CE, was independently associated with ankle pVAS. US examination is useful to illustrate RA ankle involvement, especially for patients who complain ankle pain but lack CE findings.

  2. Utility of Ultrasonography for Urinary Tract Infections of Infants

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Chul Ho; Kim, Yun Jeong [Dongnam Health Univ., Seoul (Korea, Republic of)

    2009-06-15

    In this study, we investigated utility of ultrasonography for urinary tract infections of infants. The results of the research is as follows : 1. The number of infants under one year old was 100 out of 122 infants who were diagnosed as a unitary infection. The ratio of males to females was 1.7 : 1. Seventy-seven infants who underwent three kinds of radiologic examinations such as kidney sonography (51%), {sup 99m}TC DMSA-scan (42%), and VCUG (22%). 2. In comparison of correlation between kidney sonography and VCUG, the sensitivity of kidney sonography was 82% while the specificity of kidney sonography was 58%. In comparison of correlation between kidney sonography and {sup 99m}TC DMSA-scan, the sensitivity of kidney sonography was 66% while the specificity of kidney sonography was 67%. 3. Utility of kidney sonography showed the highest efficiency when we considered pain, discomfort, a sense of shame, psychological stress when infants may undergo at the examination, side-effect of a contrast agent after the examination, and complication of exposure to radiation.

  3. The usefulness of transvaginal ultrasonography and MRI in endometrial carcinoma

    International Nuclear Information System (INIS)

    Yoshihara, Eisuke

    1992-01-01

    Between October 1988 and March 1991, 29 patients with endometrial carcinoma had both transvaginal ultrasonography (TVUS) and magnetic resonance imaging (MRI) performed following hysterectomy at the Department of Gynecology and Obstetrics, Okayama University Medical School. The findings were compared with the pathological findings to determine the usefulness of each method. The sensitivity of detecting myometrial invasion was 100% by TVUS and 96% by MRI. The accuracy was 86% by each method. The depth of myometrial invasion was classified into 3 degrees [no myometrial invasion, superficial invasion (≤1/2), deep invasion (>1/2)]. The correct diagnostic rate was 86% by TVUS and MRI. The minimum width and the minimum/maximum width ratio of the intact myometrium obtained by each method in the pathological deep invasion group were significantly lower than those obtained in the other two groups (p<0.01). The sensitivity, the accuracy and the specificity for detecting cervical invasion were 89%, 93% and 95% by both methods. There was no difference between TVUS and MRI for diagnosing myometrial and cervical invasion of endometrial carcinoma. (author)

  4. Clinical diagnostic potentials of thyroid ultrasonography and scintigraphy; An evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Torizuka, Tatsuo; Kasagi, Kanji; Hatabu, Hiroto; Misaki, Takashi; Iida, Yasuhiro; Konishi, Junji (Kyoto Univ. (Japan). Hospital); Endo, Keigo

    1993-06-01

    This prospective study was designed to evaluate the potential contributions of high resolution ultrasonography (US) and Tc-99m scintigraphy in the routine diagnosis of thyroid disease. The diagnostic impacts of US and Tc-99m scintigraphy results in 177 patients visiting our thyroid clinic were assessed and scored according to the following criteria: when the information provided by either test supported, confirmed or changed the initial clinical diagnosis, they received scores of 2, 3 and 4 respectively, while score 1 was given when the test itself was useless for the differential diagnosis. US identified focal lesions that both palpation and scintigraphy had failed to detect in 14 (12.1%) of 116 patients with diffuse thyroid diseases, suggesting the necessity of Hashimoto's thyroiditis, adenoma, adenocarcinoma and adenomatous goiter, and vice versa in the diagnosis of hyperthyroid and euthyroid Graves's diseases. Thus, the advantages of US over scintigraphy for morphological evaluation were confirmed. US was particularly useful for the differential diagnosis of adenomatous goiter from Hashimoto's thyroiditis or a single nodular disease. In contrast, scintigraphy gave functional images, being especially helpful for the differential diagnosis of thyrotoxicosis. (author).

  5. Utility of Ultrasonography for Urinary Tract Infections of Infants

    International Nuclear Information System (INIS)

    Yoon, Chul Ho; Kim, Yun Jeong

    2009-01-01

    In this study, we investigated utility of ultrasonography for urinary tract infections of infants. The results of the research is as follows : 1. The number of infants under one year old was 100 out of 122 infants who were diagnosed as a unitary infection. The ratio of males to females was 1.7 : 1. Seventy-seven infants who underwent three kinds of radiologic examinations such as kidney sonography (51%), 99m TC DMSA-scan (42%), and VCUG (22%). 2. In comparison of correlation between kidney sonography and VCUG, the sensitivity of kidney sonography was 82% while the specificity of kidney sonography was 58%. In comparison of correlation between kidney sonography and 99m TC DMSA-scan, the sensitivity of kidney sonography was 66% while the specificity of kidney sonography was 67%. 3. Utility of kidney sonography showed the highest efficiency when we considered pain, discomfort, a sense of shame, psychological stress when infants may undergo at the examination, side-effect of a contrast agent after the examination, and complication of exposure to radiation.

  6. Imperforate Anus: Determination of Type Using Transperineal Ultrasonography

    International Nuclear Information System (INIS)

    Choi, Young Hun; Kim, In One; Cheon, Jung Eun; Kim, Woo Sun; Yeon, Kyung Mo

    2009-01-01

    This study was designed to assess the usefulness of transperineal ultrasonography (US) for the determination of imperforate anus (IA) type. From January 2000 to December 2004, 46 of 193 patients with an IA underwent transperineal US prior to corrective surgery. Sonographic findings were reviewed to identify the presence of internal fistulas and to determine 'distal rectal pouch to perineum (P-P)' distances. IA types were determined based on the sonographic findings, and the diagnostic accuracy of transperineal US was evaluated based on surgical findings. Of the 46 patients, 17 patients were surgically confirmed as having a high-type IA, three patients were confirmed as having an intermediate-type IA and 26 patients were confirmed as having a low-type IA. The IA type was correctly diagnosed by the use of transperineal US in 39 of the 46 patients (85%). In 14 of the 17 patients with a high-type IA, internal fistulas were correctly identified. All cases with a P-P distance > 16 mm were high-type IAs and all cases with a P-P distance < 5 mm were low-type IAs. Transperineal US is a good diagnostic modality for the identification of internal fistulas in cases of high-type IA and for defining the IA level

  7. Value of ultrasonography in the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Sohn, Seok Ho; Jung, Kun Sik; Kim, Jung Sik; Woo, Seong Ku; Chung, Ki Yong; Kim, Hee Jin

    1993-01-01

    During a 12-month period high-resolution, real-time ultrasonography (US) with graded compression was performed on 268 consecutive patients with clinically suspected acute appendicitis and its complications. US visualization of a fluid-filled, non-compressed appendix or a decompressed, thick-walled appendix was the primary criterion for a diagnosis of acute appendicitis. The sonographic findings were correlated with surgical-pathologic outcome in 92 cases and with the findings of clinical follow-ups in the remainder. US was found to be accurate in the diagnosis of acute appendicitis and its complication with a sensitivity of 93.3%, a specificity of 98.9%, and an accuracy of 97%. The predictive value of a positive test was 97.7%; that of a negative test was 96.7%. There were two false-positive examinations in patients with a thick-walled appendix or periapperdiceal abscess, which were surgically confirmed as appendiceal adenocarcinoma and perforated cecal diverticulitis respectively. There were six false-negative examinations in patients with a sonographically no-visible appendix, which were confirmed surgically as acute appendicitis (n=5) and perforated appendicitis (n=1). Our results show that high-resolution, real-time US is an accurate imaging modality in the diagnosis of acute appendicitis and the evaluation of its complications

  8. Double contrast-enhanced ultrasonography in the detection of periampullary cancer: Comparison with B-mode ultrasonography and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ting [Department of Medical Image Center, Zhujiang Hospital, Southern Medical University, Guangzhou (China); Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Su, Zhong-zhen; Wang, Ping; Wu, Tao [Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Tang, Wen [Department of Radiology, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Xu, Er-jiao; Ju, Jin-xiu [Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Quan, Xian-yue, E-mail: quanxianyue2014@163.com [Department of Medical Image Center, Zhujiang Hospital, Southern Medical University, Guangzhou (China); Zheng, Rong-qin, E-mail: zhengrq@mail.sysu.edu.cn [Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China)

    2016-11-15

    Purpose: To investigate the value of double contrast-enhanced ultrasonography (DCEUS) in the detection of periampullary cancer. Materials and methods: Ninety-nine patients with surgery or biopsy-proven periampullary cancer who underwent both DCEUS and magnetic resonance imaging (MRI) examinations before operation were enrolled in our study. DCEUS in which intravenous microbubbles were used in combination with oral contrast agent and MRI were performed preoperatively to make a detection diagnosis of periampullary cancer. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of DCEUS, B-mode ultrasonography (BUS) and MRI were calculated and compared. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy of BUS, DCEUS and MRI in the detection. Stratified analyses were performed for different pathological types and different sizes of periampullary lesions. The inter- and intra-observer reliability of DCEUS for cancer detection was also investigated. Result: There were no significant differences in sensitivity, specificity, PPV, NPV or accuracy between DCEUS and MRI (all P > 0.05). ROC analysis showed that the accuracy of DCEUS or MRI was higher than that of BUS (P < 0.001), while no significant differences were noted in the accuracy between DCEUS and MR. In the 76 cases of periampullary cancer, DCEUS appeared to be superior to BUS for ampullary carcinoma, duodenum carcinoma and for lesions with an average diameter of less than 3 cm. DCEUS appeared equal to BUS in other groups. No significant differences were noted between DCEUS and MRI in the stratified analysis. A considerably well agreement between DCEUS and MRI was obtained using Kappa analysis (k = 0.649, P < 0.001). The intra- and inter-observer reproducibility were both good for detection of periampullary cancer by DCEUS, with a Kappa values of 0.783 (P < 0.01) and 0.732 (P < 0.01), respectively. Conclusion: DCEUS provides an

  9. Spindle epithelial tumor with thymus-like differentiation of the thyroid gland: A case report with ultrasonography and CT features, cytological findings and histopathological results

    International Nuclear Information System (INIS)

    Kang, Dong Joo; Lee, Yoo Jin; Kim, Dong Wook; Jung, Soo Jin

    2016-01-01

    Spindle epithelial tumor with thymus-like differentiation (SETTLE) of the thyroid gland is a very rare tumor. It is believed to originate from ectopic thymus tissue within the thyroid gland or from branchial pouch remnants that differentiate along the thymic line. A few reports of SETTLE have been presented, but to the best of our knowledge, there is no case report in which detailed preoperative imaging features of SETTLE have been described. In addition, there are no case reports of SETTLE in Korean patients. Thus, we report a case of SETTLE with detailed preoperative ultrasonography and computed tomography features, cytological findings and histopathological results

  10. Spindle epithelial tumor with thymus-like differentiation of the thyroid gland: A case report with ultrasonography and CT features, cytological findings and histopathological results

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dong Joo; Lee, Yoo Jin; Kim, Dong Wook; Jung, Soo Jin [Busan Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)

    2016-11-15

    Spindle epithelial tumor with thymus-like differentiation (SETTLE) of the thyroid gland is a very rare tumor. It is believed to originate from ectopic thymus tissue within the thyroid gland or from branchial pouch remnants that differentiate along the thymic line. A few reports of SETTLE have been presented, but to the best of our knowledge, there is no case report in which detailed preoperative imaging features of SETTLE have been described. In addition, there are no case reports of SETTLE in Korean patients. Thus, we report a case of SETTLE with detailed preoperative ultrasonography and computed tomography features, cytological findings and histopathological results.

  11. Does Prebiopsy, Nonsterile Ultrasonography Gel Affect Biopsy-Site Asepsis?

    International Nuclear Information System (INIS)

    Gurel, Kamil; Karabay, Oguz; Gurel, Safiye; Hildebolt, Charles

    2008-01-01

    Purpose. The purpose of this study was to determine the extent to which the use of nonsterile gel, prior to antiseptic procedures in ultrasonography (US)-guided percutaneous biopsies, results in contamination of the biopsy site. Materials and Methods. Patients referred for US-guided percutaneous biopsies were included in this study. Transmission material used for US evaluation before biopsy-site antiseptic procedures were performed was either nonsterile gel or sterile saline. Patients were randomly assigned to two groups: nonsterile gel (n = 30) and sterile saline (n = 30). Before the transmission material was used and after antiseptic procedures were performed, microbial swabs of a 10-cm 2 -diameter area were obtained at the biopsy site. Swabs were also obtained from the gel, saline, and povidine-iodine. Inoculated specimen plates were incubated at 37 o C under aerobic conditions, and the numbers of colony-forming units recorded. Nominal logistic regression analysis was used to calculate the odds of postantisepsis bacterial growth (after antiseptic procedures were performed) based on group, gender, coincidental disease (diabetes, chronic renal failure, and malignancy), biopsy-site location (head and neck or breast and abdomen), and local factors (skin fold, skin tag, and hair). Results. The following odds ratios (adjusted for the other variables) and their 95% confidence intervals were calculated: (1) group (2.9 [0.8-11.1]; p = 0.10); (2) gender (1.2 [0.3-5.2]; p = 0.78); (3) coincidental disease (7.6 [0.9-166.7]; p = 0.09); (4) biopsy site location (6.2 [1.4-31.3]; p = 0.02); and (5) local factors (7.0 [1.6-36.0]; p = 0.01). No bacterial growth occurred with swabs obtained from gel, povidine-iodine, or saline. Conclusion. We conclude that nonsterile gel used prior to percutaneous biopsy does not affect biopsy-site asepsis

  12. Evaluation of real time ultrasonography of the normal pancreas

    International Nuclear Information System (INIS)

    Kim, H. K.; Ko, Y. T.; Kim, S. Y.; Ahn, C. Y.

    1981-01-01

    91 cases who were free of pancreatic disease and the related conditions, were studied by high resolution and wide field real time ultrasonographic scanner with 3.5 MHz linear array electronically focusing transducers. The pancreatic examination method and the anatomic structures in and around the pancreas were investigated, and the normal pancreatic findings by real time ultrasonography were as follows: 1. Among all 91 cases, 44 cases were male and 47 cases female, and the frequent age groups were the 4th to the sixth decade. 2. The pancreatic images were obtained in 86% and the good images in 65%. 3. The shapes of pancreas were sausage (40%), dumb-bell (34%), tadpole (9%), and club (17%). 4. Pancreatic size was 1.56 ± 0.37, 2.4, 0.8 cm (Mean ± SD, Max., Min.) in head, 1.32 ± 0.29, 2.0, 0.8 cm in isthmus, and 1.62 ± 0.31, 2.4, 1.0 cm in tail. 5. The successful rate of pancreatic duct visualization was 46%. The shapes of pancreatic duct were linear (22%), tramline (16%), and tubular (8%). 6. The pancreatic echogenecity is greater than that of the liver in 68%, and equivalent to that of the liver in 32%, and no normal pancreas displayed less echogenecity than the liver. 7. Pancreatic echogenecity is lesser than that of adjacent soft tissue in 79% and equivalent to that of adjacent soft tissue in 21%. 8. The pancreatic echogenecity is homogenous in 79%. 9. The pancreatic margin is smooth in 62%, undulated in 11%, and ill defined in 27%

  13. Quantitative Assessment of Hepatic Fibrosis by Contrast-enhanced Ultrasonography

    Institute of Scientific and Technical Information of China (English)

    Ming-bo Zhang; En-ze Qu; Ji-Bin Liu; Jin-rui Wang

    2011-01-01

    Objective To explore the contrast-enhanced ultrasonographic features for quantitative assessment of hepatic fibrosis.Methods 86 patients with chronic viral hepatitis B were enrolled in this study from March 2007 to August 2009.The patients were classified into 5 groups (S0-S4) according to fibrosis stage evaluated with ultrasound guided liver biopsy.New contrast-enhanced ultrasonography (CEUS) features including area under the time-intensity curve (TIC) of portal venous phase/hepatic arterial phase (Qp/Qa) and intensity of portal venons phase/hepatic arterial phase (Ip/Ia) were used to detect the blood supply ratio (portal vein/hepatic artery) in each group.Arrival time of portal vein trunk (Tp) and decreasing rate of TIC (β) were also analyzed.Results Qp/Qa and Ip/Ia decreased from So to S4,while Tp and β increased These 4 features were significantly correlated with the degree of fibrosis (P<0.001) and were significantly different among the five groups (P<0.001).Sensitivity and specificity of Ip/Ia were 80% and 86% for groups ≥S1,75% and 86% for groups ≥ S2,71% and 84% for groups ≥ S3,and 76% and 80% for group S4,respectively.Sensitivity and specificity of Qp/Qa were 70% and 88% for groups ≥ S1,80% and 76% for groups ≥ S2,74% and 70% for groups ≥ S3,and 81% and 95% for group S4,respectively.Conclusion Ip/Ia and Qp/Qa could be adopted as reliable,non-invasive features for quantitative assessment of hepatic fibrosis.

  14. Evaluation of peripheral enthesitis in spondyloarthritis: Ultrasonography versus clinical examination

    Directory of Open Access Journals (Sweden)

    Anupam Wakhlu

    2017-01-01

    Full Text Available Background: Enthesitis is an important feature of spondyloarthritis but may often be subclinical. Data is sparse, especially from India, on the ultrasonography (USG detection of enthesitis in these patients. The present study aimed to find the prevalence and pattern of entheseal involvement assessed clinically and by USG. Methods: Fifty-two spondyloarthritis, 26 rheumatoid arthritis, and 26 healthy controls were evaluated for enthesitis by clinical examination and by USG using 2014 OMERACT consensus group definitions at bilateral Achilles insertion on the calcaneus, plantar fascia attachment on the calcaneus, quadriceps tendon insertion on the patella, patellar tendon origin from the inferior pole of the patella, and patellar tendon insertion on the tibial tuberosity. At least one ultrasonographic finding at any of the above sites was considered positive for enthesitis. Results: The number of entheseal sites screened in spondyloarthritis patients was 520 and 260 each in rheumatoid arthritis and healthy controls. USG (sensitivity - 94.2% was better in detecting enthesitis than clinical examination (sensitivity - 69.2%. Clinical examination was highly specific (100% compared to USG (55.7% in differentiating from rheumatoid arthritis and healthy controls. USG alone without clinical findings was positive at 23.8% of sites while clinical examination alone without USG findings was positive at 5.2% of sites. Frequency of enthesitis in rheumatoid arthritis was not more than healthy controls (6.1% vs. 8.1%, respectively and was much less than spondyloarthritis (34%. Conclusion: USG is a good screening tool for detection of enthesitis but cannot replace clinical examination completely.

  15. Prediction of cerebrovascular reserve by the MRI and doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hui Joong; Kim, Yong Sun [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2005-07-15

    We investigated acute stroke patterns on diffusion weighted images and with doppler ultrasonography studies of ICA and MCA steno-occlusive diseases in order to predict the cerbrovascular reserve (CVR), as was measured by acetazolamide (ACZ)-challenged Tc-99m ECD brain perfusion SPECT. A retrospective analysis was performed of 76 patients who underwent MRI/MRA, ACZ-challenged Tc-99m ECD brain perfusion SPECT, and carotid and vertebral artery Doppler sonography. After dividing these patients into four groups-MCA and ICA ateno-occlusions, we analyzed the relationship between the CVR and topologic MR patterns and the flow volume, as was measured by Doppler sonography. The CVRs were preserved in 26 of 76 patients. The CVRs were impaired in those cases of occlusion that were detected on MRA and also by the pattern of the territorial involvement on the diffusion weighted image ({rho} < 0.05, x{sup 2} test). Yet in cases of preserved CVRs, the flow volume of the contralateral ICA, the anterior circulation, and the total cerebral flow volume were increased, as was checked by Doppler sonography ({rho} < 0.05, t-test). As calculated by logistic regression analysis, the accuracy for predicting the preserved CVR by using the statistically significant variables was 78%. We believe that the MRI-SPECT correlation study was helpful for understanding the hemodynamics and topographic patterns of ischemia in patients with ICA and MCA steno-occlusive disease, and that the flow volume measurement, which was done by using duplex US, was useful for predicting the CVR.

  16. Comparison of the capsular width measured on ultrasonography and MR image of the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae Wan; Yoo, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Dankook University, Seoul (Korea, Republic of)

    2006-03-15

    To evaluate the reliability and clinical usefulness of ultrasonography in the temporomandibular joint(TMJ). Parasagittal and paracoronal 1.5 T MR images and 7.5 MHz ultrasonography of 40 TMJs in 20 asymptomatic volunteers were obtained. Disc position using MR imaging was evaluated and the distance between the lateral surface of mandibular condyle and the articular capsule using MR image and ultrasonography of 27 TMJs with normal disc position was measured and compared. Intraobserver and interobserver measurements reliability was evaluated by using interclass correlation coefficients (ICC) and measurement error. Also, the distance measured on ultrasonography was compared, according to mouth position and disc position. The normal disc position was found in 27 of 40 asymptomatic joints. At the intraobserver reliability of measurement, ICC at the closed and open mouth position were 0.89 and 0.91. The measurement error was 0.4% and 0.5%. At the interobserver reliability, ICC at the closed and open mouth position, the distances between the lateral surface of mandibular condyle and the articular capsule measured on MR images and ultrasonography were 2.0{+-} 0.7 mm, 1.8{+-}0.5 mm, respectively (p<0.05). On the ultrasonography, the distances at open mouth position were 1.2{+-}0.5 mm (p<0.05). At the TMJ with medially displaced disc, the distances at the closed and open mouth position were 1.3{+-}0.3 mm and 0.9{+-}0.2 mm (p<0.05). The results suggest ultrasonography of TMJ is a reliable imaging technique for assessment of normal disc position.

  17. Reliability of Ultrasonography in Confirming Endotracheal Tube Placement in an Emergency Setting

    Science.gov (United States)

    Thomas, Vimal Koshy; Paul, Cherish; Rajeev, Punchalil Chathappan; Palatty, Babu Urumese

    2017-01-01

    Background and Objectives: Over the past few years, ultrasonography is increasingly being used to confirm the correct placement of endotracheal tube (ETT). In our study, we aimed to compare it with the traditional clinical methods and the gold standard quantitative waveform capnography. Two primary outcomes were measured in our study. First was the sensitivity and specificity of ultrasonography against the other two methods to confirm endotracheal intubation. The second primary outcome assessed was the time taken for each method to confirm tube placement in an emergency setting. Methods: This is a single-centered, prospective cohort study conducted in an emergency department of a tertiary care hospital. We included 100 patients with indication of emergency intubation by convenient sampling. The intubation was performed as per standard hospital protocol. As part of the study protocol, ultrasonography was used to identify ETT placement simultaneously with the intubation procedure along with quantitative waveform capnography (end-tidal carbon dioxide) and clinical methods. Confirmation of tube placement and time taken for the same were noted by three separate health-care staffs. Results and Discussion: Out of the 100 intubation attempts, five (5%) had esophageal intubations. The sensitivity and specificity of diagnosis using ultrasonography were 97.89% and 100%, respectively. This was statistically comparable with the other two modalities. The time taken to confirm tube placement with ultrasonography was 8.27 ± 1.54 s compared to waveform capnography and clinical methods which were 18.06 ± 2.58 and 20.72 ± 3.21 s, respectively. The time taken by ultrasonography was significantly less. Conclusions: Ultrasonography confirmed tube placement with comparable sensitivity and specificity to quantitative waveform capno