Sample records for ultrasonic surgical aspiration

  1. Tumour reduction with a Cavitron Ultrasonic Surgical Aspirator® in ...

    African Journals Online (AJOL)

    of a scarf made the patient appear natural and presentable. Figure 1: The fungating tumour before tumour reduction with a Cavitron Ultrasonic Surgical Aspirator®. Tumour reduction with a Cavitron Ultrasonic. Surgical Aspirator® in the palliative care of anaplastic thyroid cancer. CASE REPORT. JHR Becker,1,2 F Ghoor1,2.

  2. Debridement of vaginal radiation ulcers using the surgical Ultrasonic Aspirator

    International Nuclear Information System (INIS)

    Vanderburgh, E.; Nahhas, W.A.

    1990-01-01

    The surgical Ultrasonic Aspirator (USA) is a fairly new surgical instrument used for an increasingly wide range of procedures. This paper introduces a new application: debridement of vulvovaginal necrotic ulcers resulting from intracavitary radiation therapy. The ultrasonic aspirator allowed removal of the soft, necrotic tissue while preserving underlying healthy, firm tissue and blood vessels

  3. Real time analysis of brain tissue by direct combination of ultrasonic surgical aspiration and sonic spray mass spectrometry.

    Science.gov (United States)

    Schäfer, Karl-Christian; Balog, Júlia; Szaniszló, Tamás; Szalay, Dániel; Mezey, Géza; Dénes, Júlia; Bognár, László; Oertel, Matthias; Takáts, Zoltán

    2011-10-15

    Direct combination of cavitron ultrasonic surgical aspirator (CUSA) and sonic spray ionization mass spectrometry is presented. A commercially available ultrasonic surgical device was coupled to a Venturi easy ambient sonic-spray ionization (V-EASI) source by directly introducing liquified tissue debris into the Venturi air jet pump. The Venturi air jet pump was found to efficiently nebulize the suspended tissue material for gas phase ion production. The ionization mechanism involving solely pneumatic spraying was associated with that of sonic spray ionization. Positive and negative ionization spectra were obtained from brain and liver samples reflecting the primary application areas of the surgical device. Mass spectra were found to feature predominantly complex lipid-type constituents of tissues in both ion polarity modes. Multiply charged peptide anions were also detected. The influence of instrumental settings was characterized in detail. Venturi pump geometry and flow parameters were found to be critically important in ionization efficiency. Standard solutions of phospholipids and peptides were analyzed in order to test the dynamic range, sensitivity, and suppression effects. The spectra of the intact tissue specimens were found to be highly specific to the histological tissue type. The principal component analysis (PCA) and linear discriminant analysis (LDA) based data analysis method was developed for real-time tissue identification in a surgical environment. The method has been successfully tested on post-mortem and ex vivo human samples including astrocytomas, meningeomas, metastatic brain tumors, and healthy brain tissue. © 2011 American Chemical Society

  4. Glioma tissue obtained by modern ultrasonic aspiration with a simple sterile suction trap for primary cell culture and pathological evaluation.

    Science.gov (United States)

    Schroeteler, Juliane; Reeker, Ralf; Suero Molina, Eric; Brokinkel, Benjamin; Holling, Markus; Grauer, Oliver M; Senner, Volker; Stummer, Walter; Ewelt, Christian

    2014-01-01

    Ultrasonic aspiration is widely used in the resection of brain tumors. Nevertheless, tumor tissue fragments obtained by ultrasonic aspiration are usually discarded. In this study, we demonstrate that these fragments are possible sources of material for histopathological study and tissue culture and compare their microscopic features and viability in tissue culture of cavitron ultrasonic surgical aspirator tissue fragments. Brain tumor tissue collected by ultrasonic aspiration (CUSA EXcel®; Integra Radionics Inc.) in a simple sterile suction trap during resection was processed for primary cell culture. Cell viability and immunohistological markers were measured by the WST-1 test, microscopy and immunofluorescent evaluation. Six gliomas are presented to demonstrate that these tissue fragments show good preservation of histological detail and tissue viability in culture. Utilization of this material may facilitate pathological interpretation by providing a more representative sample of tumor histology as well as an adequate and sterile biosource of material for tissue culture studies.

  5. Glioma spheroids obtained via ultrasonic aspiration are viable and express stem cell markers

    DEFF Research Database (Denmark)

    Jensen, Stine Skov; Aaberg-Jessen, Charlotte; Andersen, Claus

    2013-01-01

    Ultrasonic aspirators allow safe, rapid, and accurate removal of brain tumors. However, the tissue fragments removed are used surprisingly little in research.......Ultrasonic aspirators allow safe, rapid, and accurate removal of brain tumors. However, the tissue fragments removed are used surprisingly little in research....

  6. Application of CUSA Excel ultrasonic aspiration system in resection of skull base meningiomas.

    Science.gov (United States)

    Tang, Hailiang; Zhang, Haishi; Xie, Qing; Gong, Ye; Zheng, Mingzhe; Wang, Daijun; Zhu, Hongda; Chen, Xiancheng; Zhou, Liangfu

    2014-12-01

    Here, we introduced our short experience on the application of a new CUSA Excel ultrasonic aspiration system, which was provided by Integra Lifesciences corporation, in skull base meningiomas resection. Ten patients with anterior, middle skull base and sphenoid ridge meningioma were operated using the CUSA Excel ultrasonic aspiration system at the Neurosurgery Department of Shanghai Huashan Hospital from August 2014 to October 2014. There were six male and four female patients, aged from 38 to 61 years old (the mean age was 48.5 years old). Five cases with tumor located at anterior skull base, three cases with tumor on middle skull base, and two cases with tumor on sphenoid ridge. All the patents received total resection of meningiomas with the help of this new tool, and the critical brain vessels and nerves were preserved during operations. All the patients recovered well after operation. This new CUSA Excel ultrasonic aspiration system has the advantage of preserving vital brain arteries and cranial nerves during skull base meningioma resection, which is very important for skull base tumor operations. This key step would ensure a well prognosis for patients. We hope the neurosurgeons would benefit from this kind of technique.

  7. Case of minute hepatocellular carcinoma found by CT scan and diagnosed cytology under the ultrasonic aspiration transducer

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Waichi; Moriai, Norihiko; Komatsu, Kanji [Yuri Kumiai Sogo Hospital, Akita (Japan)

    1983-11-01

    CT scan detected a suspected minute hepatocellular carcinoma in a case of liver cirrhosis followed up for more than 10 years. A definite diagnosis was established by ultrasonic guided aspiration cytology. The cancer was resected using ultrasonic examination during operation.

  8. Application of B-ultrasonic guided fine needle aspiration cytology in diagnosis of tuberculous lymphadenitis

    International Nuclear Information System (INIS)

    Yu Qi; Yang Jianghui; Li Ning

    2011-01-01

    To explore the value of B-ultrasonic guided fine needle aspiration cytology(FNAC) in the diagnosis of tuberculous lymphadenitis (TB). The patients were carried out FNAC under B-ultrasonic guidance to distinguish the tuberculosis lymphadenitis. With the FNAC diagnosis of lymphoglandulae and reactive hyperplasia lesions of 80 cases, 41 cases were confirmed by histopathology. With FNAC diagnosed tuberculosis 36 cases, granulomatous lymphadenitis 2 cases and reactive hyperplasia 3 cases. FANC is one of efficient method to diagnosis the tuberculous lymphadenitis. This method has some limitations, but it could be overcome by biopsy or polymerase chain reaction. (authors)

  9. Glioma Surgical Aspirate: A Viable Source of Tumor Tissue for Experimental Research

    International Nuclear Information System (INIS)

    Day, Bryan W.; Stringer, Brett W.; Wilson, John; Jeffree, Rosalind L.; Jamieson, Paul R.

    2013-01-01

    Brain cancer research has been hampered by a paucity of viable clinical tissue of sufficient quality and quantity for experimental research. This has driven researchers to rely heavily on long term cultured cells which no longer represent the cancers from which they were derived. Resection of brain tumors, particularly at the interface between normal and tumorigenic tissue, can be carried out using an ultrasonic surgical aspirator (CUSA) that deposits liquid (blood and irrigation fluid) and resected tissue into a sterile bottle for disposal. To determine the utility of CUSA-derived glioma tissue for experimental research, we collected 48 CUSA specimen bottles from glioma patients and analyzed both the solid tissue fragments and dissociated tumor cells suspended in the liquid waste fraction. We investigated if these fractions would be useful for analyzing tumor heterogeneity, using IHC and multi-parameter flow cytometry; we also assessed culture generation and orthotopic xenograft potential. Both cell sources proved to be an abundant, highly viable source of live tumor cells for cytometric analysis, animal studies and in-vitro studies. Our findings demonstrate that CUSA tissue represents an abundant viable source to conduct experimental research and to carry out diagnostic analyses by flow cytometry or other molecular diagnostic procedures

  10. Ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage

    International Nuclear Information System (INIS)

    Naper, M.A.; Shaikh, M.S.; Dholia, K.R.

    2017-01-01

    To evaluate the outcome and assess the success rate of ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage. Methodology: A prospective descriptive study was carried out at Department of Surgery, Chandka Medical College Hospital, Larkana, Pakistan, from January 2015 to December 2015. A total of 111 patients of breast abscess who underwent ultrasound guided aspiration without anesthesias with oral antibiotic cover were studied. Females with breast abscess within seven days, and the abscess size was <3cm were included in the study. Males, antibioma and inflammatory carcinoma were excluded from the study. Outcome of success or failure was observed within two weeks and recorded. Results: Out of 111 patients, 68.46% were lactating and 31.53% were non-lactating women, with ages ranging from 18 to 60 years (mean 36.5 years). The successful rate with complete resolution after ultrasound guided aspiration was observed in 94.5%. 80.82% responded after single aspiration, 12.38% after two times aspiration, and 6.66% after multiple aspirations, while 5.4% of patients required incision and drainage. Conclusion: Ultrasound guided aspiration of breast abscess is an effective treatment option with a diameter of <3cm, which can be recommended as a routine outpatient procedure. (author)

  11. Impact of cavitron ultrasonic surgical aspirator (CUSA) and bipolar radiofrequency device (Habib-4X) based hepatectomy for hepatocellular carcinoma on tumour recurrence and disease-free survival.

    Science.gov (United States)

    Huang, Kai-Wen; Lee, Po-Huang; Kusano, Tomokazu; Reccia, Isabella; Jayant, Kumar; Habib, Nagy

    2017-11-07

    The aim of this study was to evaluate the oncological outcomes of hepatocellular carcinoma patients undergoing liver resection using cavitron ultrasonic surgical aspirator (CUSA) or radiofrequency (RF) based device Habib-4X.
. We prospectively analyzed the data of 280 patients who underwent liver resection for hepatocellular carcinoma at our institution from 2010-2012 with follow up till August 2016. The CUSA was used in the 163 patients whilst Habib-4X in 117 patients. The end points of analysis were oncological outcomes as disease recurrence, disease-free survival (DFS) and overall survival (OS) were estimated by the Kaplan-Meier method, which has been compared with all other existing literature on the survival study. Compared with CUSA the reported incidence of recurrence was significantly lower, in Habib-4X group; p Habib-4X group than CUSA group (50.80 vs 45.87 months, p = 0.03). The median OS was better in Habib-4X group than CUSA group (60.57 vs 57.17 months, p = 0.12) though the lesser difference in OS between the groups might be explained by the use of palliative therapies as TACE, percutaneous RFA, etc. in case of recurrence. RF based device Habib-4X, is safe and effective device for resection of hepatocellular carcinoma, in comparison to CUSA with better oncological outcomes, i.e., significantly lesser tumour recurrence and better DFS. This could be explained on the basis of systemic and local immunomodulatory effect involving induction of kupffer cells and effector CD-8 T cells that help in minimizing postoperative complications and bring more advantageous oncological outcomes.

  12. Miniinvasive paracentetic drain surgical interventions under ultrasonic control concerning liquid formations of abdominal cavity

    Directory of Open Access Journals (Sweden)

    G.I. Ohrimenko

    2013-08-01

    Full Text Available Entry. Presently miniinvasive surgical interventions under ultrasonic control became the method of choice in treatment of quite a number of abdominal and retroperitoneal organs diseases, and their complications. These operations have a row of advantages, as compared to open and laparoscopic ones: comparative simplicity, insignificant infecting of abdominal region, least of intra- and postoperative complications. Actuality of problem is conditioned by that indications to the use of paracentetic drain surgical interventions, most optimal methods of preoperative diagnostic, features of postoperative treatment of patients remain not enough studied. Research aim. To study the results of diagnostics and treatment of patients with liquid formations of abdominal cavity that were exposed to miniinvasive surgical interventions under ultrasonic control and, on the basis of it, to work out an optimal curative diagnostic algorithm. Materials and research methods. The results of treatment of 25 patients with liquid formations of abdominal cavity are analyzed. They were submitted to miniinvasive paracentetic drain surgical interventions under ultrasonic control. The pseudocysts of pancreas were in 16 patients, abscesses of abdominal cavity – in 2 patients. Research results. Intraoperative complications were not marked. Postoperative complications were observed in 5 patients. Among them there were inadequate drainage of all cavities of multicamerate abscess of the liver in 2 patients, progress of sacculated uremic peritonitis developing in presence of ascites in one patient, and arrosive hemorrhage in the cavity of pancreas pseudocyst in 2 persons. It is determined that it is necessary to include the spiral computer tomography to the complex of preoperative inspection of patients that allows to diagnose multicamerate abscess of the liver in time and to drain all the additional cavities adequately. 2 patients after paracentetic drain surgical interventions

  13. Medical Officers in Sierra Leone: Surgical Training Opportunities, Challenges and Aspirations.

    Science.gov (United States)

    Wilks, Lucy; Leather, Andrew; George, Peter Matthew; Kamara, Thaim Bay

    2018-02-05

    The critical shortage of human resources for healthcare falls most heavily on sub-Saharan nations such as Sierra Leone, where such workforce deficits have grave impacts on its burden of surgical disease. An important aspect in retention and development of the workforce is training. This study focuses on postgraduate surgical training (formal and short course) and perceptions of opportunities, challenges and aspirations, in a country where more than half of surgical procedures are performed by medical officers. The study presents findings from 12 in-depth semi-structured interviews conducted with medical officers by the primary investigator in Sierra Leone between April and June 2017. Each interview was transcribed alongside an introspective reflexive journal to acknowledge and account for researcher biases. Two interviewees had accessed postgraduate surgical training and 10 (83%) had accessed short course surgically relevant training. The number of short courses accessed grew higher the more recently the medical officers had graduated. Supervision, short length and international standards were the most appreciated aspects of short training courses. Some medical officers perceived the formal postgraduate surgical training programme to be ill-equipped, doubting its credibility. This demotivated some from applying. Training is an essential aspect of developing an adequate surgical workforce. Faith must be restored in the capabilities of Sierra Leone's Ministry of Health and Sanitation to provide adequate and sustainable training. This study advocates for the use of short courses to restore this faith and the expansion of postgraduate surgical training to the districts through developing a regional teaching complex to provide short courses and eventually formal postgraduate training in the future. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  14. Comparison of frequency of recurrence following aspiration and injection of steroid versus surgical excision in the treatment of wrist ganglion

    International Nuclear Information System (INIS)

    Butt, M.W.; Mian, M.A.; Ahmed, N.; Aziz, U.B.A.

    2014-01-01

    To compare the frequency of recurrence following aspiration and injection of steroid versus surgical excision in the treatment of wrist ganglion. Study Design: Randomized controlled trial.Place and Duration of Study: General surgical department, Combined Military Hospital, Rawalpindi, Pakistan, from Jan 2010 to Dec 2010. Material and Methods: Sixty patients of clinically diagnosed wrist ganglia were randomized into groups 'A' and 'B' with 30 patients in each group. After approval by the hospital ethical committee, patients in group 'A' were subjected to aspiration and injection of methyl-prednisolone acetate 40 mg/ml and those in group 'B' underwent surgical excision of the ganglion. Patients were explained the procedure they were subjected to and they were also counselled about the risk of recurrence after a particular procedure and after that informed written consent was obtained from them. Patients were followed up at intervals of 2 weeks, 6 weeks, 3 months and 6 months after the procedure to look for recurrence in both groups. Results: On follow up at 6 months, 12 (40%) patients in group A while only 2 (6.66%) patients in group B had recurrence of the ganglion. No complications were noted. This difference was found to be statistically significant (p=0.0023). Conclusion: Recurrence of wrist ganglion is considerably less in patients treated with surgical excision and should be preferred over aspiration and steroid injection. (author)

  15. Rehabilitation with 4 zygomatic implants with a new surgical protocol using ultrasonic technique.

    Science.gov (United States)

    Mozzati, Marco; Mortellaro, Carmen; Arata, Valentina; Gallesio, Giorgia; Previgliano, Valter

    2015-05-01

    When the residual bone crest cannot allow the placement of standard implants, the treatment for complete arch rehabilitation of severely atrophic maxillae can be performed with 4 zygomatic implants (ZIs) and immediate function with predictable results in terms of aesthetics, function, and comfort for the patient. However, even if ZIs' rehabilitations showed a good success rate, this surgery is difficult and need a skillful operator. Complications in this kind of rehabilitation are not uncommon; the main difficulties can be related to the reduced surgical visibility and instrument control in a critical anatomic area. All the surgical protocols described in the literature used drilling techniques. Furthermore, the use of ultrasonic instruments in implant surgery compared with drilling instruments have shown advantages in many aspects of surgical procedures, tissues management, enhancement of control, surgical visualization, and healing. The aim of this study was to report on the preliminary experience using ultrasound technique for ZIs surgery in terms of safety and technical improvement. Ten consecutive patients with severely atrophic maxilla have been treated with 4 ZIs and immediate complete arch acrylic resin provisional prostheses. The patients were followed up from 30 to 32 months evaluating implant success, prosthetic success, and patient satisfaction with a questionnaire. No implants were lost during the study period, with a 100% implant and prosthetic success rate. Within the limitations of this preliminary study, these data indicate that ultrasonic implant site preparation for ZIs can be a good alternative to the drilling technique and an improvement for the surgeon.

  16. How to select aspirant laparoscopic surgical trainees: establishing concurrent validity comparing Xitact LS500 index performance scores with standardized psychomotor aptitude test battery scores

    NARCIS (Netherlands)

    Schijven, Marlies P.; Jakimowicz, Jack J.; Carter, Fiona J.

    2004-01-01

    BACKGROUND: Although a controversial topic in medical education, the selection of aspirant surgical trainees is a subject that needs to be addressed. In the view of preventing surgical trainee drop-outs and of appropriate allocation of limited resources, it is an issue critical to the profession.

  17. Thin needle aspiration biopsy in diagnosis of thyroid gland carcinoma

    International Nuclear Information System (INIS)

    Nikolaeva, T. V.; Smolenskaya, N. A.; Rafeenko, S.M.; Rekechinskaya, N.V.; Krupnik, Ye.V.; Aladieva, L.A.; Krupnik, T. A.

    2001-01-01

    The increase of thyroid gland cancer in people of Belarus is one of the most actual medical problems appeared after the Chernobyl disaster. During the period 1986 -1999 in Belarus were revealed 6901 cases of cancer in the adults and 673 -in the children. Compared with the pre-disaster period the increase of the pathology has made 4.7 and 84 times correspondingly. In Magilew region during post-disaster years were revealed 899 cases of thyroid gland cancer in the adults and 34 -in the children. From the year 1998 perceptible rise of disease appeared in people over 19 years old. According to the prognosis of specialists the problem of high thyroid gland carcinoma rate will be actual for years, gradually decreasing in the children and increasing in the adults. Thyroid gland cancer promoted by radiation has very aggressive nature. According to the data of Republican science-practical thyroid gland tumors center even small carcinomas (3-9 mm) can give numerous metastasis to lymph nodes and lungs. The possibility of tumor growth to the nearest tissues is very high. That's why the early diagnostic of the pathology is important. Medical help to the patients with thyroid gland cancer and other node formations consist in the complex problem solution: early node formation revealing by ultrasonic method, early diagnosis verification with the help of cytological bio-assays examination, received by the way of the thin needle aspiration biopsy (TNAB) under ultrasonic control, surgical treatment, radio iodine therapy, rehabilitation and prophylactic medical examination. Under the problem of early thyroid carcinoma revealing they understand exact diagnostic and surgical treatment in the stages pT1, pT1a and pT1b, N0, M0. In 1993 -1999 in the diagnostic center 139,2 thousand patients were surveyed. In the pointed cases 10739 thin needle aspiration biopsies under ultrasonic control were made and the bioassays received were studied cytologically. Ultrasonic examinations and TNAB were

  18. 21 CFR 872.4850 - Ultrasonic scaler.

    Science.gov (United States)

    2010-04-01

    ... DEVICES DENTAL DEVICES Surgical Devices § 872.4850 Ultrasonic scaler. (a) Identification. An ultrasonic scaler is a device intended for use during dental cleaning and periodontal (gum) therapy to remove calculus deposits from teeth by application of an ultrasonic vibrating scaler tip to the teeth. (b...

  19. Ultrasonic imaging of metastatic carcinoma in thyroid gland

    International Nuclear Information System (INIS)

    Bai Ling; Yang Tao; Tang Ying; Mao Jingning; Chen Wei; Wang Wei

    2008-01-01

    Objectives: To explore the ultrasonic findings of metastatic thyroid carcinoma and to evaluate the diagnostic value of the ultrasonic imaging for patients with metastatic thyroid neoplasm. Methods: The ultrasonic imaging characteristics of ten patients who were diagnosed with metastatic thyroid carcinoma were retrospectively analyzed. In all the cases, fine-needle aspiration cytology (FNAC) of the thyroid was performed during the clinical diagnosis. Results: The ultrasonic images of the ten patients fell into four types: multiple nodules in the thyroid, single nodule in the thyroid, diffuse calcification and heterogeneous echo. Seven cases showed speckled calcific foci. Abnormal blood flow signal was found in 9 cases. Conclusion: The ultrasonic findings of metastatic carcinoma in the thyroid gland are various and non-specific. Color Doppler ultrasound may provide ample evidence. The diagnosis depends on FNAC. (authors)

  20. Presence in the pre-surgical fine-needle aspiration of potential thyroid biomarkers previously identified in the post-surgical one.

    Directory of Open Access Journals (Sweden)

    Federica Ciregia

    Full Text Available Fine-needle aspiration biopsy (FNA is usually applied to distinguish benign from malignant thyroid nodules. However, cytological analysis cannot always allow a proper diagnosis. We believe that the improvement of the diagnostic capability of pre-surgical FNA could avoid unnecessary thyroidectomy. In a previous study, we performed a proteome analysis to examine FNA collected after thyroidectomy. With the present study, we examined the applicability of these results on pre-surgical FNA. We collected pre-surgical FNA from 411 consecutive patients, and to obtain a correct comparison with our previous results, we processed only benign (n=114, papillary classical variant (cPTC (n=34 and papillary tall cell variant (TcPTC (n=14 FNA. We evaluated levels of five proteins previously found up-regulated in thyroid cancer with respect to benign nodules. ELISA and western blot (WB analysis were used to assay levels of L-lactate dehydrogenase B chain (LDHB, Ferritin heavy chain, Ferritin light chain, Annexin A1 (ANXA1, and Moesin in FNA. ELISA assays and WB analysis confirmed the increase of LDHB, Moesin, and ANXA1 in pre-surgical FNA of thyroid papillary cancer. Sensitivity and specificity of ANXA1 were respectively 87 and 94% for cPTC, 85 and 100% for TcPTC. In conclusion, a proteomic analysis of FNA from patients with thyroid nodules may help to distinguish benign versus malignant thyroid nodules. Moreover, ANXA1 appears to be an ideal candidate given the high sensitivity and specificity obtained from ROC curve analysis.

  1. Secondary Voice Restoration After Laryngotracheal Separation (LTS) for Dysphagia with Intractable Aspiration.

    Science.gov (United States)

    Bonte, Katrien; Huvenne, Wouter; De Loof, Marie; Deron, Philippe; Viaene, Annick; Duprez, Fréderic; Vermeersch, Hubert

    2015-12-01

    Intractable aspiration is a serious, often life-threatening condition due to its potential impact on pulmonary function. Aspiration requires therapeutic measures, starting with conservative management but often necessitating surgical treatment. The basic surgical principle is to separate the alimentary and respiratory tracts through a variety of procedures which, unfortunately, nearly all result in the loss of phonation, with the exception of total laryngectomy (TL) which includes the placement of an indwelling voice prosthesis. In this study, we present a modified laryngotracheal separation (LTS) technique that, we believe, offers multiple advantages compared to standard TL. After reviewing the medical records of 35 patients with intractable aspiration who have undergone LTS, we describe the surgical technique and present the postoperative result. In a second surgical procedure about two months following LTS, we aimed to achieve voice restoration by placement of an indwelling voice prosthesis. Intractable aspiration was successfully treated in all patients. Placement of an indwelling voice prosthesis during a second operation was successful in 15 patients, representing the largest reported cohort thus far. LTS is a reliable surgical technique to treat intractable aspiration, with restoration of oral intake, thereby improving the general condition and quality of life of these unfortunate patients. Furthermore, voice restoration can be achieved in selected patients, by placement of a voice prosthesis.

  2. Treatment of Patellar Tendinopathy Refractory to Surgical Management Using Percutaneous Ultrasonic Tenotomy and Platelet-Rich Plasma Injection: A Case Presentation.

    Science.gov (United States)

    Nanos, Katherine N; Malanga, Gerard A

    2015-12-01

    Chronic proximal patellar tendinopathy is a common condition in sports medicine that may be refractory to nonoperative treatments, including activity modification, medications, and comprehensive rehabilitation. Percutaneous ultrasonic tenotomy is a recently developed technique designed to cut and debride tendinopathic tissue, thus promoting pain relief and functional recovery. We present a case of a collegiate athlete with chronic proximal patellar tendinopathy who was effectively treated with percutaneous ultrasonic tenotomy after not responding to extensive nonoperative treatment, surgical debridement, and platelet-rich plasma injections. Percutaneous ultrasonic tenotomy can be considered as a treatment option in patients presenting with refractory proximal patellar tendinopathy, including those who do not respond to previous operative intervention. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  3. Glottal insufficiency with aspiration risk in dysphagia.

    Science.gov (United States)

    Giraldez-Rodriguez, Laureano A; Johns, Michael

    2013-12-01

    Glottal closure is an important part of the mechanism that protects the airway during the normal swallow. Glottal insufficiency disrupts glottal closure and therefore puts patients at risk of aspiration. Treatment of glottal insufficiency can be classified as surgical or nonsurgical. The objective of treating glottal insufficiency is to avoid aspiration or penetration of secretions or food into the airway. Nonsurgical treatment consists of swallowing maneuvers and other measures. Surgical treatment of glottal insufficiency includes injection laryngoplasty, medialization thyroplasty with or without arytenoid adduction or with arytenopexy and cricothyroid subluxation, hypopharyngoplasty, cricopharynx muscle dilation, and cricopharynx myotomy. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Ultrasound guided percutaneous fine needle aspiration biopsy of the liver with focal lesion

    International Nuclear Information System (INIS)

    Ko, Gang Seok; Yang, Hyun Cheol; Park, Byoung Lan; Kim, Byoung Geun; Sohn, Jang Sihn

    1985-01-01

    The ultrasound-guided fine needle aspirations were performed in order to diagnose a suspected neoplastic or infectious disease in 52 patients with focal liver disease. Of these, neoplastic lesions were suspected in 31 patients and infectious lesions in 21 patients ultrasonically and/or clinically. The overall accuracy for both suspected malignant and infectious disease was 79% (41/52). The primary indication for fine needle aspiration was to document the presence of malignancy and to avoid a diagnostic laparotomy, and to drain hepatic abscess. Consequently we were convinced that the ultrasound-guided percutaneous fine needle aspiration biopsy in the focal liver disease is the best method for a conclusive diagnosis

  5. Radiological differential diagnosis in chronic aspiration pneumonia

    International Nuclear Information System (INIS)

    Hannig, C.; Wuttge-Hannig, A.; Hoermann, M.; Herrmann, I.F.; Neurologische Klinik Muenchen Tristanstrasse; Wuerzburg Univ.

    1989-01-01

    6% of all patients suffering from a cerebro-vascular injury die from aspiration pneumonia within the first year. The high temporal resolution of high-speed cineradiography (HFK) (50 frames/sec.) allows the recording of the 0.7 sec. process of pharyngeal swallow. Five case-examples are presented (total number of cases: 95) illustrating the possibility of differentiation between three types of aspiration by means of cineradiography. These types are the so-called pre-, intra- and postdeglutitive aspiration, that is aspiration before or after triggering of the swallowing reflex. This differentiation is of great therapeutic importance. The analysis of disturbances of pharyngo-laryngeal motility and the temporal coordination allows setting up individual surgical and/or conservative programme for rehabilitation. (orig.) [de

  6. Surgical treatment for mediastinal abscess induced by endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    Science.gov (United States)

    Yokoyama, Yujiro; Nakagomi, Takahiro; Shikata, Daichi; Higuchi, Rumi; Oyama, Toshio; Goto, Taichiro

    2017-07-14

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a useful and less invasive procedure for the definitive diagnosis of mediastinal and hilar lymph nodes. However, infectious complications can occur after EBUS-TBNA, although they are extremely rare. A 66-year-old man with necrotic and swollen lower paratracheal lymph nodes underwent EBUS-TBNA. A mediastinal abscess developed 9 days post-procedure. Surgical drainage and debridement of the abscess were performed along with lymph node biopsy followed by daily washing of the thoracic cavity. Surgical treatment was effective, leading to remission of the abscess. Biopsy revealed that the tumor was squamous cell carcinoma with no radiologically detected cancer elsewhere in the body. Mediastinal lung cancer was thus confirmed. Subsequent chemoradiotherapy led to the remission of the tumor. Mediastinitis after EBUS-TBNA is rare but should be considered, particularly if the target lymph nodes are necrotic. Mediastinitis can lead to serious and rapid deterioration of the patient's condition, for which surgical intervention is the treatment of choice.

  7. A single-blind controlled study of electrocautery and ultrasonic scalpel smoke plumes in laparoscopic surgery.

    Science.gov (United States)

    Fitzgerald, J Edward F; Malik, Momin; Ahmed, Irfan

    2012-02-01

    Surgical smoke containing potentially carcinogenic and irritant chemicals is an inevitable consequence of intraoperative energized dissection. Different energized dissection methods have not been compared directly in human laparoscopic surgery or against commonly encountered pollutants. This study undertook an analysis of carcinogenic and irritant volatile hydrocarbon concentrations in electrocautery and ultrasonic scalpel plumes compared with cigarette smoke and urban city air control samples. Once ethical approval was obtained, gas samples were aspirated from the peritoneal cavity after human laparoscopic intraabdominal surgery solely using either electrocautery or ultrasonic scalpels. All were adsorbed in Tenax tubes and concentrations of carcinogenic or irritant volatile hydrocarbons measured by gas chromatography. The results were compared with cigarette smoke and urban city air control samples. The analyzing laboratory was blinded to sample origin. A total of 10 patients consented to intraoperative gas sampling in which only one method of energized dissection was used. Six carcinogenic or irritant hydrocarbons (benzene, ethylbenzene, styrene, toluene, heptene, and methylpropene) were identified in one or more samples. With the exception of styrene (P = 0.016), a nonsignificant trend toward lower hydrocarbon concentrations was observed with ultrasonic scalpel use. Ultrasonic scalpel plumes had significantly lower hydrocarbon concentrations than cigarette smoke, with the exception of methylpropene (P = 0.332). No significant difference was observed with city air. Electrocautery samples contained significantly lower hydrocarbon concentrations than cigarette smoke, with the exception of toluene (P = 0.117) and methyl propene (P = 0.914). Except for toluene (P = 0.028), city air showed no significant difference. Both electrocautery and ultrasonic dissection are associated with significantly lower concentrations of the most commonly detected carcinogenic and

  8. Use of ultrasonic dissection in the early surgical management of periorbital haemangiomas.

    Science.gov (United States)

    Claude, O; Picard, A; O'Sullivan, N; Baccache, S; Momtchilova, M; Enjolras, O; Vazquez, M P; Diner, P A

    2008-12-01

    To evaluate the efficacy and safety of the early surgical excision of periorbital haemangiomas with an ultrasonic scalpel in infants at risk of visual impairment. A retrospective analysis of 67 infants diagnosed to be at risk of amblyopia from periorbital haemangiomas, treated consecutively with the Dissectron between 1994 and 2005. Ophthalmic outcome parameters included the pre- and postoperative measurement of visual axis occlusion, strabismus, astigmatism, and degree of amblyopia. Visual performance showed an overall improvement of 30% following treatment. Seventy-six patients were found to have abnormal ophthalmic examinations preoperatively, compared to 46 following surgery. After surgery, visual axis occlusion decreased from 73 to 6%; amblyopia decreased from 67 to 22%, strabismus decreased from 26 to 18% and astigmatism (>onedioptre) decreased from 66 to 31%. Mean astigmatism values decreased from 3.5 to 1.9 dioptres. No new cases of astigmatism, strabismus or amblyopia were diagnosed postoperatively. Three minor complications resolved with conservative treatment. All patients were satisfied with the outcome of their surgery. Early surgical excision of periorbital haemangiomas using the Dissectron in infants with an established risk of visual impairment is a safe and effective alternative to pharmacological therapy. The use of the Dissectron is associated with reduced operative times and a shorter hospital stay.

  9. Percutaneous aspiration of hydatid cysts

    International Nuclear Information System (INIS)

    Hernandez, G.; Serrano, R.

    1996-01-01

    A perspective study was carried out to assess the efficacy of a combination of percutaneous aspiration plus oral albendazole to assess its efficacy as an alternative to surgery in the treatment of hydatid cyst. We performed percutaneous aspiration followed by injection of 20% hypertonic saline solution into 16 hydatid cysts in 13 patients. All the patients received oral albendazole (400 mg/12 hours) starting 2 days before and lasting until there weeks after the procedure. There were no anaphylactic reactions during or after the procedure. Follow-up included monthly ultrasound over a period ranging between 10 and 36 months. Three cysts disappeared completely; in 10 cases, the cysts cavity was replaced by a complex ultrasonographic findings, with strong signals similar to those of a pseudotumor. In another case, the aspirate was sterile and its morphology remained unchanged. In two cases, infection of the cyst ensued, requiring surgical treatment. We consider that percutaneous aspiration in combination with albendazole may prove to be a good alternative to surgery for the management of hepatic hydatid disease. (Author) 15 refs

  10. Recurrent Aspiration Pneumonia due to Anterior Cervical Osteophyte

    Directory of Open Access Journals (Sweden)

    Jae Jun Lee

    2017-02-01

    Full Text Available A 74-year-old man presented with recurrent vomiting and aspiration pneumonia in the left lower lobe. He entered the intensive care unit to manage the pneumonia and septic shock. Although a percutaneous endoscopic gastrostomy tube was implanted for recurrent vomiting, vomiting and aspiration recurred frequently during admission. Subsequently, he complained of neck pain when in an upright position. A videofluoroscopic swallowing study showed compression of the esophagus by cervical osteophytes and tracheal aspiration caused by an abnormality at the laryngeal inlet. Cervical spine X-rays and computed tomography showed anterior cervical osteophytes at the C3-6 levels. Surgical decompression was scheduled, but was cancelled due to his frailty. Unfortunately, further recurrent vomiting and aspiration resulted in respiratory arrest leading to hypoxic brain damage and death. Physicians should consider cervical spine disease, such as diffuse skeletal hyperostosis as an uncommon cause of recurrent aspiration pneumonia.

  11. RT-06GAMMA KNIFE SURGERY AFTER NAVIGATION-GUIDED ASPIRATION FOR CYSTIC METASTATIC BRAIN TUMORS

    Science.gov (United States)

    Chiba, Yasuyoshi; Mori, Kanji; Toyota, Shingo; Kumagai, Tetsuya; Yamamoto, Shota; Sugano, Hirofumi; Taki, Takuyu

    2014-01-01

    Metastatic brain tumors over 3 cm in diameter (volume of 14.1ml) are generally considered poor candidates for Gamma Knife surgery (GKS). We retrospectively assessed the method and efficacy of GKS for large cystic metastatic brain tumors after navigation-guided aspiration under local anesthesia. From September 2007 to April 2014, 38 cystic metastatic brain tumors in 32 patients (12 males, 20 females; mean age, 63.2 years) were treated at Kansai Rosai Hospital. The patients were performed navigation-guided cyst aspiration under local anesthesia, then at the day or the next day, were performed GKS and usually discharged on the day. The methods for preventing of leptomeningeal dissemination are following: 1) puncture from the place whose cerebral thickness is 1 cm or more; 2) avoidance of Ommaya reservoir implantation; and 3) placement of absorbable gelatin sponge to the tap tract. Tumor volume, including the cystic component, decreased from 25.4 ml (range 8.7-84.7 ml) to 11.4 ml (range 2.9-36.7 ml) following aspiration; the volume reduction was approximately 51.6%. Follow-up periods in the study population ranged from 0 to 24 months (median 3.5 months). The overall median survival was 6.7 months. There was no leptomeningeal dissemination related to the aspiration. One patient experienced radiation necrosis after GKS, one patient experienced re-aspiration by failure of aspiration, and two patients experienced surgical resections and one patient experienced re-aspiration by cyst regrowth after GKS. Long-term hospitalization is not desirable for the patients with brain metastases. In japan, Long-term hospitalization is required for surgical resection or whole brain radiation therapy, but only two days hospitalization is required for GKS after navigation-guided aspiration at our hospital. This GKS after navigation-guided aspiration is more effective and less invasive than surgical resection or whole brain radiation therapy.

  12. Comparative study of aspiration and non-aspiration cytology of palpable breast lumps and correlation with histopathology

    Directory of Open Access Journals (Sweden)

    S Koirala

    2014-09-01

    Full Text Available Background: Breast lump is one of the most common presentations in surgical outpatient departments with anxiety regarding a possible malignancy. Hence a quick diagnosis of a lump in the breast is essential. Fine needle aspiration cytology is an ideal initial diagnostic modality in breast lumps. There is an alternative method of performing needle aspiration, known as fine needle capillary cytology where the specimen is obtained using just a needle without aspiration.Materials and Methods: This hospital-based cross sectional analytical study was carried out in Department of Pathology in National Academy of Medical Sciences, Bir Hospital for one year. The objective of this study was to compare aspiration and non-aspiration cytology of palpable breast lumps and correlation with histopathology.Results: The five criteria scored for each technique were background blood, amount of cellular material, cellular degeneration, cellular trauma and architectural preservation. Compared to fine needle aspiration cytology, fine needle capillary cytology yields less bloody smears with minimal degenerative changes and offers more diagnostically superior specimens. Fine needle aspiration cytology, on the other hand, gives a good yield of diagnostic material.Conclusion: Fine needle aspiration cytology and fine needle capillary cytology are quick, easy, safe and cost-effective techniques. . A high sensitivity and specificity of cytological diagnosis in this study proves that it is comparable to final histology report in its diagnostic efficiency. Thus, fine needle aspiration cytology is a very important preliminary diagnostic test in palpable breast lumps and the results show a high degree of correlation with the final histopathology report.DOI: http://dx.doi.org/10.3126/jpn.v4i8.11501 Journal of Pathology of Nepal; Vol.4,No. 8 (2014 639-643

  13. Gynecomastia associated with herniated nipples: an optimal surgical approach.

    Science.gov (United States)

    Jaiswal, Rohit; Pu, Lee L Q

    2012-04-01

    Gynecomastia is a common disorder observed in male plastic surgery patients. Treatment options may include observation, surgical excision, or liposuction techniques. Congenital herniated nipple is a more rare condition, especially in male patients. We present the case of a 12-year-old boy with bilateral gynecomastia and herniated nipple-areolar complexes. A staged repair was undertaken in this patient with grade 2 gynecomastia. The first operation was ultrasonic liposuction bilaterally, yielding 200 mL of aspirate from the left and 400 mL on the right, to correct the gynecomastia. The second procedure, performed 6 months later, was a bilateral periareolar mastopexy to repair the herniated nipple-areolar complexes. The result of the first procedure was flattened and symmetrical breast tissue bilaterally, essentially a correction of the gynecomastia. The herniated nipples were still present, however. Bilateral periareolar mastopexies were then performed with resulting reduction of the herniations. There were no complications with either procedure, and a good cosmetic result was achieved. A staged surgical approach was successful in correcting both conditions with an excellent aesthetic result and the advantage of decreased risk for nipple complications.

  14. Endometriome: Aspiration versus Operation // Endometrioma: Aspiration versus Surgery

    Directory of Open Access Journals (Sweden)

    Sommergruber M

    2016-01-01

    Full Text Available Endometriosis is often associated with sterility. In 20–50 % of women with endometriosis the ovaries are affected. Ovarian endometrioma often present with inhomogeneous ultrasound patterns. The differentiation to other ovarian tumors could be difficult. In case of primary diagnosis, histological findings are indicated, all the more as ovarian endometriosis has an increased risk for malignant transformation. Therapeutic surgical intervention should be done in sano.brNevertheless, to affect a compromise in case of infertility, especially in patients with reduced ovarian reserve, laparoscopic aspiration or laser coagulation after fenestration could be a second option with the occurrence of small recurrent endometriomas. A histological diagnosis should be done, too. The surgical procedure should be discussed with the department of reproductive medicine.brThe effect of endometriomas on the reproductive outcome is not clear. Systematic reviews have shown that regarding pregnancy rates, endometriomas do not have to be necessarily removed. Primary ultrasound-guided transvaginal aspiration of endometriomas should be avoided to decrease the risk of infection. If the same is the truth in case of accidental aspiration during the oocyte retrieval, remains unproven. Contaminated follicular fluid by endometrioma content may have an influence on clinical pregnancy and live birth rate. p bKurzfassung: /bEndometriose und Sterilität sind häufig assoziiert. Bei 20–50 % aller Frauen mit Endometriose sind die Ovarien befallen. Ovarielle Endometriome weisen häufig ein typisches echoinhomogenes Schallmuster auf, sind aber nicht immer eindeutig gegenüber anderen Ovarialtumoren abgrenzbar. Eine histologische Abklärung ist daher bei Erstdiagnose indiziert, umso mehr als ein erhöhtes Entartungsrisiko bei ovarieller Endometriose nachgewiesen wurde. Therapeutisch sollte die Resektion in sano erfolgen.brGleichwohl sind dabei wegen des oft gebotenen Erhalts der

  15. Percutaneous Needle Aspiration Is A Minimally Invasive Method For A Breast Abscess

    Directory of Open Access Journals (Sweden)

    Hamid H. Sarhan

    2012-04-01

    Results: Twenty-three (53.4% of the patients obtained complete resolution (no focal collection after one aspiration; 9 (21% required two aspirations and 8 (18.6% required more than two aspirations for the cure (residual collection. In 3 (7% of the patients, the treatment failed, where symptoms had not resolved after 3 days, with further pus collection despite aspiration and antibiotics, where surgical drainage was required. Conclusions: Percutaneous needle drainage of breast abscesses after preliminary breast US is feasible as a primary and definitive treatment for breast abscesses, if complete or near complete drainage is achieved. [Arch Clin Exp Surg 2012; 1(2.000: 105-109

  16. Ultrasound-guided needle aspiration of parotid abscess

    Directory of Open Access Journals (Sweden)

    André Takahashi

    2012-01-01

    Full Text Available Ultrasound (US has been used as a tool for parotid abscess diagnosis and treatment. The present article aimed to report a case of 72-year-old woman with parotid abscess treated by US-guided needle aspiration and conventional surgical drainage. Along with the clinical report, indications, advantages, and limitations of the method are discussed.

  17. Combined debridement in chronic wounds: a literature review

    OpenAIRE

    Liu, Wan-Lin; Jiang, Yun-Lan; Wang, Yan-Qiao; Li, Ying-Xin; Liu, Yi-Xian

    2017-01-01

    Wounds debridement is important for healing of chronic wounds. Combined debridement is a new technique to deal with the complex chronic wounds. This review introduces several topical methods of combined debridement according to the various color classifications. Methods include combined sharp and hydrogel debridement, combined ultrasonic and enzymatic debridement, ultrasonic debridement combined with surgical debridement and vacuum aspiration on debridement, and other types of debridement. Th...

  18. Clinical experience with aspiration of breast abscesses based on size and etiology at an academic medical center.

    Science.gov (United States)

    Giess, Catherine S; Golshan, Mehra; Flaherty, Karen; Birdwell, Robyn L

    2014-01-01

    Our purpose was to review needle aspiration of breast abscesses and identify factors associated with treatment by aspiration alone versus aspiration with surgical incision and drainage (I/D). This Institutional Review Board-approved, retrospective review of the breast ultrasound database from 2008 to 2010 identified 40 patients (41 abscesses) who underwent aspiration, with or without I/D. Demographics, imaging, number of aspirations, and microbiology were reviewed. Twenty-two abscesses underwent aspiration only, 16 > 3 cm, 6 ≤ 3 cm (mean 4.3 cm, range 0.9-10 cm). Known risk factors included lactational (11), 3 weeks post partum (1), pregnancy (1), recent biopsy/lumpectomy (5). Nineteen abscesses underwent aspiration and I/D, 15 > 3 cm, 4 ≤ 3 cm (mean 4.1 cm, range 2.2-7.5 cm). Known risk factors included lactational (4), recurrent subareolar abscess (4), diabetes (3), hydradenitis suppuritiva (1), nipple piercing (2), smoking (1), pregnancy (1), HIV (1), and lumpectomy (1). Identified reasons for I/D included lack of improvement/recurrence (12), fistula (3), and one electively after clinical improvement of a recurrent subareolar abscess. Abscesses associated with pregnancy and lactation or breast biopsy are effectively managed with aspiration, even when large. Recurrence, chronicity, or fistula may require surgical intervention. © 2014 Wiley Periodicals, Inc.

  19. Surgical smoke.

    Science.gov (United States)

    Fan, Joe King-Man; Chan, Fion Siu-Yin; Chu, Kent-Man

    2009-10-01

    Surgical smoke is the gaseous by-product formed during surgical procedures. Most surgeons, operating theatre staff and administrators are unaware of its potential health risks. Surgical smoke is produced by various surgical instruments including those used in electrocautery, lasers, ultrasonic scalpels, high speed drills, burrs and saws. The potential risks include carbon monoxide toxicity to the patient undergoing a laparoscopic operation, pulmonary fibrosis induced by non-viable particles, and transmission of infectious diseases like human papilloma virus. Cytotoxicity and mutagenicity are other concerns. Minimisation of the production of surgical smoke and modification of any evacuation systems are possible solutions. In general, a surgical mask can provide more than 90% protection to exposure to surgical smoke; however, in most circumstances it cannot provide air-tight protection to the user. An at least N95 grade or equivalent respirator offers the best protection against surgical smoke, but whether such protection is necessary is currently unknown.

  20. The value of fine needle aspiration and cytologic examination of impalpable complicated breast cysts.

    Science.gov (United States)

    Tez, Selda; Dener, Cenap; Köktener, Aslý; Caydere, Muzaffer; Tez, Mesut

    2008-01-01

    The purpose of the study was to evaluate the utility of fine needle aspiration--FNA and cytologic analysis of impalpable complicated breast cysts. We rewieved the imaging findings, aspiration, cytology and biopsy results and followup imaging findings of 246 complicated cysts in 166 women retrospectively. FNA was performed in 169 out of the 246 complicated cysts. Thirtyone lesions were followed-up with US. Surgical biopsy was performed from five lesions. No malignant cells (137 cysts), insufficient cellular material (17 cysts), atypical cells (4 cysts) were seen in cytological examination of the aspirates. None of these lesions were found to represent malignancy at the time of surgical excision and during follow-up. Impalpable complicated breast cysts may be classified as probably benign and can be managed with follow-up imaging studies instead of intervention. Routine cytologic examination is unnecessary if the fluid is not bloody (Tab. 2, Ref. 18). Full Text (Free, PDF) www.bmj.sk.

  1. Bone marrow aspiration

    Science.gov (United States)

    Iliac crest tap; Sternal tap; Leukemia - bone marrow aspiration; Aplastic anemia - bone marrow aspiration; Myelodysplastic syndrome - bone marrow aspiration; Thrombocytopenia - bone marrow aspiration; Myelofibrosis - bone marrow aspiration

  2. Vocal fold immobility and aspiration status: a direct replication study.

    Science.gov (United States)

    Leder, Steven B; Suiter, Debra M; Duffey, Dianne; Judson, Benjamin L

    2012-06-01

    The purpose of this direct replication study was to confirm the incidence of vocal fold immobility (VFI) and its relationship to pharyngeal dysphagia and aspiration. Using a single-group consecutively referred case series, a total of 2,650 participants underwent fiberoptic endoscopic evaluation of swallowing between August 2003 and December 2007. Main outcome measures included overall incidence of VFI and aspiration status, with specific emphasis on age, gender, etiology and pharyngeal phase bolus flow characteristics, and side of VFI (right, left, or bilateral). These data were compared to and then combined with the original study (n = 1,452) for a total of 4,102 participants. Results indicated that the incidence of VFI was 4.3% (112/2,650), i.e., 27% (31/112) unilateral right, 58% (65/112) unilateral left, and 14% (16/112) bilateral. Incidence of aspiration was 22% (580/2,650). Of those with VFI, 40% (45/112) aspirated, i.e., 42% (13/31) unilateral right, 37% (24/65) unilateral left, and 50% (8/16) bilateral. An individual with VFI had 2.50 times the odds of aspirating as someone without VFI (95% CI = 1.86-3.37). For liquid aspiration, the odds ratio (OR) = 2.41 (95% CI = 1.77-3.28), and for puree aspiration, OR = 2.08 (95% CI = 1.47-2.93). Left VFI occurred most frequently due to surgical trauma. Liquid was aspirated more often than a puree. Males exhibited VFI more often than females. Side of VFI and age were not factors that increased the incidence of aspiration significantly. It was confirmed that VFI is not an uncommon finding during dysphagia testing and, when present, increased the odds of aspiration compared to a population already being evaluated for dysphagia.

  3. Clinical Usefulness of Ultrasonography-Guided Aspiration Cytology for Nonpalpable Breast Lesions

    International Nuclear Information System (INIS)

    Park, Jeong Mi; Kim, Jun Hyoung; Choi, Yong Baik; Gong, Gyung Yub

    1996-01-01

    To evaluate the clinical utility of the ultrasonography (US)-guided aspiration cytology for nonpalpable breast lesions. US-guided aspiration cytology was performed in 50 lesions in 37 patients who underwent US of the breasts and axillary area. Adequacy for the pathologic diagnosis was correlated with the size, volume, depth of the lesions and type of needles. The causes of inadequacy and complications were assessed. Available mammographic findings were correlated with US findings. Final diagnoses on surgical biopsy were correlated with the diagnoses on aspiration cytology. Thirty four of the 50 lesions were adequate for pathologic diagnosis (68%). The size and volume of the lesions were not significantly related with adequacy.Shallow depth was significantly better. Cutting needles were better than plain needles. Causes of inadequacy were low cell number and bleeding. Complications were small amount of bleeding and pain. Mammographic findings were nonspecific in 61% of the cases. Pathologic diagnoses were ductal hyperplasia and fibrocystic changes in 62%.Surgical biopsy was done in 5 cases. None of the lesions showed malignancy. US-guidance is necessary and effective for the cytologic diagnoses of the nonpalpable lesions. However, invasive procedure could be deferred for several months for these nonpalpable small lesions which are mostly benign

  4. Clinical Usefulness of Ultrasonography-Guided Aspiration Cytology for Nonpalpable Breast Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Mi; Kim, Jun Hyoung; Choi, Yong Baik; Gong, Gyung Yub [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    1996-06-15

    To evaluate the clinical utility of the ultrasonography (US)-guided aspiration cytology for nonpalpable breast lesions. US-guided aspiration cytology was performed in 50 lesions in 37 patients who underwent US of the breasts and axillary area. Adequacy for the pathologic diagnosis was correlated with the size, volume, depth of the lesions and type of needles. The causes of inadequacy and complications were assessed. Available mammographic findings were correlated with US findings. Final diagnoses on surgical biopsy were correlated with the diagnoses on aspiration cytology. Thirty four of the 50 lesions were adequate for pathologic diagnosis (68%). The size and volume of the lesions were not significantly related with adequacy.Shallow depth was significantly better. Cutting needles were better than plain needles. Causes of inadequacy were low cell number and bleeding. Complications were small amount of bleeding and pain. Mammographic findings were nonspecific in 61% of the cases. Pathologic diagnoses were ductal hyperplasia and fibrocystic changes in 62%.Surgical biopsy was done in 5 cases. None of the lesions showed malignancy. US-guidance is necessary and effective for the cytologic diagnoses of the nonpalpable lesions. However, invasive procedure could be deferred for several months for these nonpalpable small lesions which are mostly benign

  5. Fine needle aspiration diagnosis of a spontaneously infarcted fibroadenoma mimicking carcinoma: a case report.

    Science.gov (United States)

    Arora, Rajan; Abou-Bakr, Amany; Al Taleb, Ahmed

    2013-02-01

    Spontaneous infarction of fibroadenoma is an extremely rare complication in a nonpregnant/nonlactating female undergoing first-time aspiration. It can be misdiagnosed as carcinoma in all aspects of triple approach used for evaluation of patients with breast lesions. A 37-year-old woman presented to the outpatient surgical clinic with a 6-month history of a breast lump that was slowly increasing in size and had become painful during the past month. There was no history of any trauma or fine needle aspiration, and she was not pregnant or lactating. Mammogram and ultrasound revealed a 2.9-cm heterogenous hypoechoic suspicious lesion. No lymph nodes were detected in the axilla. Fine needle aspiration cytology was performed, and a diagnosis of benign breast lesion with features of infarction was rendered on cytology. The lump was excised surgically, and a histological diagnosis of infarcted fibroadenoma was made. Careful and diligent search for preserved benign epithelial cells on smears is the key to recognize this entity and avoid serious therapeutic implications.

  6. Thyroid Fine-Needle Aspiration under Ultrasound Guidance: Experience from an Academic Tertiary Care Center in Lebanon

    Directory of Open Access Journals (Sweden)

    Rita Hajj Boutros

    2017-07-01

    Full Text Available Thyroid nodules are common. Malignancy was reported in only 5-15% of cases. Fine needle aspiration under US guidance (USG-FNA proved to be accurate for the detection of thyroid cancer. This is a retrospective review of 400 radiology and cytology USG-FNA reports, randomly selected among those done at the Radiology Department at a tertiary care center in Beirut during the last five years. The specimen was inadequate in 60 (12% of cases but FNA was repeated in 10 cases only. The final diagnosis was benign in 76.7% of cases, mostly in women. 35% of the malignant and 19% of the benign nodules were hypoechoic, p=0.03. No significant correlation was observed between malignancy and other ultrasonic characteristics. Hypoechogenecity was also more common in nodules with inadequate specimen (40% versus 21.4%, p=0.01. Age, gender, location and size of the nodule did not differ between groups of adequate and inadequate specimen. In conclusion, 3 out of 4 thyroid nodules referred for USG-FNA are benign, mostly in women. Inadequate specimen was observed in 12% of cases. Hypoechogenecity but not other ultrasonic characteristics was associated with malignancy and with test failure.   Key words: Thyroid nodule, fine needle aspirate, ultrasound guidance, thyroid cancer, inadequate.

  7. Non-surgical treatment of esophageal achalasia

    OpenAIRE

    Annese, Vito; Bassotti, Gabrio

    2006-01-01

    Esophageal achalasia is an infrequent motility disorder characterized by a progressive stasis and dilation of the oesophagus; with subsequent risk of aspiration, weight loss, and malnutrition. Although the treatment of achalasia has been traditionally based on a surgical approach, especially with the introduction of laparoscopic techniques, there is still some space for a medical approach. The present article reviews the non-surgical therapeutic options for achalasia.

  8. Unilateral Acute Renal Artery Embolism: An Index Case of Successful Mechanical Aspiration Thrombectomy With Use of Penumbra Indigo Aspiration System and a Review of the Literature.

    Science.gov (United States)

    Yousif, Ali; Samannan, Rajesh; Abu-Fadel, Mazen

    2018-01-01

    Acute renal artery embolism (RAE) is a rare condition associated with significant morbidity and mortality. The treatment strategy for RAE includes anticoagulation with or without thrombolysis or surgical or endovascular embolectomy. We describe here a case presentation of acute RAE secondary to atrial fibrillation treated successfully with Penumbra Indigo Aspiration System, a novel device in peripheral endovascular interventions. Our patient had ongoing symptoms and acute renal failure on presentation with contraindication to thrombolysis given hypertensive emergency. A 6F Penumbra Aspiration catheter was used to aspirate large amounts of thrombus from segmental renal arteries with restoration of flow. Patient's symptoms and renal function returned to baseline after intervention. Penumbra system is used routinely in cerebral endovascular intervention, yet here we describe its potential use in peripheral vascular interventions in addition to a literature review of all available evidence for the different treatment modalities of acute RAE.

  9. Strategic Aspirations

    DEFF Research Database (Denmark)

    Christensen, Lars Thøger; Morsing, Mette; Thyssen, Ole

    2016-01-01

    are often encouraged by social norms, regulations, and institutions—for example, institutionalized standards for corporate social responsibility (CSR) reporting—they live through local articulations and enactments that allow organizations to discover who they are and who they might become. Strategic......Strategic aspirations are public announcements designed to inspire, motivate, and create expectations about the future. Vision statements or value declarations are examples of such talk, through which organizations announce their ideal selves and declare what they (intend to) do. While aspirations...... aspirations, in other words, have exploratory and inspirational potential—two features that are highly essential in complex areas such as sustainability and CSR. This entry takes a communicative focus on strategic aspirations, highlighting the value of aspirational talk, understood as ideals and intentions...

  10. Percutaneous ultrasonic tenotomy for chronic elbow tendinosis: a prospective study.

    Science.gov (United States)

    Barnes, Darryl E; Beckley, James M; Smith, Jay

    2015-01-01

    Elbow tendinopathy is the most common cause of elbow pain affecting active populations. Surgical excision is reserved for patients with refractory symptoms. Percutaneous ultrasonic tenotomy performed under local anesthesia also removes degenerated tissue and therefore provides an alternative treatment option to surgical excision. This investigation prospectively documented the safety and 1-year efficacy of ultrasonic percutaneous tenotomy performed by a single operator. Nineteen patients, aged 38 to 67 years, in whom >6 months of conservative management for medial (7) or lateral (12) elbow tendinopathy had failed were prospectively studied. All patients were treated with percutaneous ultrasonic tenotomy of the elbow by a single operator. Visual analog scale (VAS) for pain, the 11-item version of the Disabilities of the Arm, Shoulder, and Hand (Quick DASH) index, and the Mayo Elbow Performance Score (MEPS) were assessed by an independent observer before treatment and at 6 weeks, 3 months, 6 months, and 12 months after treatment. No procedural complications occurred. Total treatment time was elbow tendinopathy up to 1 year after the procedure. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Non-surgical treatment of esophageal achalasia

    Science.gov (United States)

    Annese, Vito; Bassotti, Gabrio

    2006-01-01

    Esophageal achalasia is an infrequent motility disorder characterized by a progressive stasis and dilation of the oesophagus; with subsequent risk of aspiration, weight loss, and malnutrition. Although the treatment of achalasia has been traditionally based on a surgical approach, especially with the introduction of laparoscopic techniques, there is still some space for a medical approach. The present article reviews the non-surgical therapeutic options for achalasia. PMID:17007039

  12. Surgical smoke and infection control.

    NARCIS (Netherlands)

    Alp, E.; Bijl, D.; Bleichrodt, R.P.; Hansson, B.M.; Voss, A.

    2006-01-01

    Gaseous byproducts produced during electrocautery, laser surgery or the use of ultrasonic scalpels are usually referred to as 'surgical smoke'. This smoke, produced with or without a heating process, contains bio-aerosols with viable and non-viable cellular material that subsequently poses a risk of

  13. Diagnostic Value of Processing Cytologic Aspirates of Renal Tumors in Agar Cell (Tissue) Blocks

    DEFF Research Database (Denmark)

    Smedts, F.; Schrik, M.; Horn, T.

    2010-01-01

    smears were prepared after each aspiration for conventional cytology and the remaining aspirate was processed for the improved agar microbiopsy (AM) method. Conventional cytology slides, AM slides and surgical specimens were diagnosed separately, after which the diagnoses were compared....... Immunohistochemistry was performed as required on the AM sections. Surgical specimens served as the gold standard. Results In 53% of conventional cytologic smears, the cellular yield was sufficient to render a correct diagnosis. In 12% the diagnosis was incorrect, in 21% only a differential diagnosis could be fin......-initiated, and in 14% too few diagnostic cells were present in the conventional smears for cytologic diagnosis. It was, however, possible to correctly diagnose histologic sections from 97% of AM tissue blocks. In 11 cases this was facilitated with immunochemistry. In only 1 case did the AM tissue block contain too few...

  14. A Novel Design of Needle Aspiration Biopsy Monitoring Instrument (NAOMI Tested on a Low Cost Chest Phantom

    Directory of Open Access Journals (Sweden)

    Surakusumah Rino Ferdian

    2016-01-01

    Full Text Available Needle biopsy is a medical intervention method for taking a lung tissue sample that suspected as a cancer. The disadvantage is the physicians directly visualize the anatomical structures in an open surgery for lung cancer biopsy procedure. There is a need to develop an instrument that may help the physician to guarantee the accuracy and efficiency while performing needle aspiration biopsy. Therefore, a needle aspiration biopsy monitoring instrument or named as NAOMI is proposed. It consists of a microcontroller system, an IMU sensor, an ultrasonic ranging module, a bluetooth module, and a 9V lithium battery. The experimental testing consist of performance testing, functional testing using chest phantom, and user acceptances. The results showed that the NAOMI improve the accuracy and efficiency while performing the needle biopsy operation.

  15. Ultrasound Guided Needle Aspiration versus Surgical Drainage in the management of breast abscesses: a Ugandan experience

    Directory of Open Access Journals (Sweden)

    Chandika Alphonce B

    2012-01-01

    Full Text Available Abstract Background Despite breast abscess becoming less common in developed countries, it has remained one of the leading causes of morbidity in women in developing countries. A randomized controlled trial was conducted at Mulago hospital complex in Kampala Uganda to establish whether ultrasound guided needle aspiration is a feasible alternative treatment option for breast abscesses. Results A total of 65 females with breast abscess were analyzed, of these 33 patients were randomized into the ultrasound guided needle aspiration and 32 patients in the Incision and drainage arm. The mean age was 23.12, most of them were lactating (66.2%, primipararous (44.6% with peripheral abscesses (73.8% located in the upper lateral quadrant (56%.The mean breast size was 3.49 cm. The two groups were comparably in demographic characteristic and breast abscess size. Survival analysis showed no difference in breast abscess healing rate between the two groups (Log rank 0.24 df 1 and P = 0.63. Incision and drainage was found to be more costly than ultrasound guided aspiration (cost effective ratio of 2.85. Conclusion Ultrasound guided needle aspiration is therefore a feasible and cost effective treatment option for both lactating and non lactating breast abscesses with a diameter up to 5 cm by ultrasound in an immune competent patient

  16. Ultrasonic Testing

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyeong Jun; Kuk, Jeong Han

    2002-02-15

    This book introduces ultrasonic testing, which tells of outline of ultrasonic testing, principle of ultrasonic testing, prosperities of ultrasonic waves, radiographic test and ultrasonic test, basic theory on ultrasonic testing, mode conversion, transmission and diffraction, ultrasonic flaw detection and probe, standard test piece and reference test piece, like KS(JIS) ASME and ASTM, classification and properties of ultrasonic testing, straight beam method, angle beam method, ASME SEC.V.Art.5 ASTMA 388 and KS B 0817 Korean industrial standard.

  17. An ultrasonic analysis of the comparative efficiency of various cardiotomy reservoirs and micropore blood filters.

    Science.gov (United States)

    Pearson, D T; Watson, B G; Waterhouse, P S

    1978-01-01

    The ability of 12 commercially available cardiotomy reservoirs to remove bubbles from aspirated blood was investigated by means of a simulated cardiopulmonary bypass circuit and an ultrasonic microbubble detector. Performance varied considerably. The number of gaseous microemboli remaining after passage of blood through the reservoir was reduced by (a) holding the blood in the reservoir, (b) reducing the volume of air mixed with the aspirated blood, and (c) using a reservoir that did not induce turbulence and that contained integral micropore filtration material. Further micropore filtration of the blood after passage through the cardiotomy reservoir was beneficial, and significantly more bubbles were extracted when the microfilter was sited below the reservoir than when it was placed in the arterial line. PMID:684672

  18. Aspiration of breast abscess under ultrasound guidance: outcome obtained and factors affecting success.

    Science.gov (United States)

    Elagili, Faisal; Abdullah, Norlia; Fong, Liew; Pei, Tan

    2007-01-01

    To assess ultrasonographically (US) guided needle aspiration of breast abscesses as an alternative to surgical incision and drainage. In our prospective study, 30 patients with 31 breast abscesses (one patient had bilateral breast abscess) underwent percutaneous breast abscess drainage under US guidance with local anaesthesia and oral antibiotics between 1 January 2004 and 31 March 2005. These patients consisted of 16 (53.3%) non-lactating and 14 (46.7%) lactating women, with ages ranging from 18 to 68 years (median, 28 years). The racial distribution comprised 26 (86.7%) Malays, three (10%) Chinese and one (3.3%) Indian. All patients had the chief complaint of breast swelling and 25 (83.3%) had breast pain. Clinically, 28 (93.3%) were found to have a palpable mass. Nine (30%) lesions were in the upper outer quadrant of the left breast. US diameters ranged from 1 to 15 cm (median, 4 cm). The pus volumes varied from 1 to 200 mL (median, 14 mL). Fifteen (50%) patients required only a single aspiration, 10 required multiple aspirations and five required incision and drainage. Those patients in whom needle aspiration failed had multiloculated lesions irrespective of abscess volume and size. Needle aspiration with ultrasound guidance is an effective treatment for breast abscess irrespective of abscess volume and size.

  19. Recurrent Aspiration in a Patient With Gastric Band Undergoing Electroconvulsive Therapy.

    Science.gov (United States)

    Lubit, Elana B; Fetterman, Tammy Cohen; Ying, Patrick

    2016-06-01

    We report a case of a 33-year-old woman with depression and suicidal ideation, treated successfully with electroconvulsive therapy (ECT) in the past. Since her previous course of ECT, she underwent gastric banding, a bariatric surgical procedure associated with increased risk of gastric regurgitation. Despite increasingly stringent measures to minimize the risk of regurgitation and aspiration during ECT, she had several episodes of regurgitation, the last of which precipitated an acute illness consistent with aspiration pneumonitis. We took additional precautions after each event, until she had no further episodes of regurgitation. We discuss the risk posed by the gastric band, the measures we implemented to minimize that risk, and our recommendations for assessment and management of post-gastric banding patients who present for ECT.

  20. A new surgical method for penile girth enhancement.

    Science.gov (United States)

    Li, Xiaoge; Tao, Ling; Cao, Chuan; Shi, Haishan; Li, Le; Chen, Liang; Li, Shirong

    2015-01-01

    We developed a new surgical model of penile girth enhancement in dog, with minimal damage, fewer complications, and high success rate, to enable the experimental investigation of penile implants. We obtained materials for penile girth enhancement by processing the pericardium and blood vessel wall collected from pigs. Incisions were made at the penile bulb for the implantation of the materials, and facilitate observation and data collection, based on the anatomical features of dog's penis. We measured the girth of the flaccid penis before and after the operation, and erectile function at 1-month postoperation. In addition to evaluation of recovery from the incision and local pathological changes, ultrasonic examination was performed to monitor the long-term changes associated with implantation. The mean girth of the flaccid penis significantly increased from 7.37±0.40 cm before the operation, to 8.70±0.56 cm postoperation. Dogs resumed normal mating at 1 month after the operation, without any significant change in the mating time. Ultrasonic examination clearly illustrated the implants, and helped in the measurement of the distance between the materials and the baculum. Chinese Rural dog is a promising animal model for penile girth enhancement surgery. The findings demonstrated that surgical implantation into penile bulb was associated with less damage, faster postoperative recovery, and higher success. For the first time, ultrasonic examination provided objective data on the surgical outcomes of penile girth enhancement.

  1. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1993-05-15

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer.

  2. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    International Nuclear Information System (INIS)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun

    1993-01-01

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer

  3. Combined use of ultrasonic-assisted liposuction and semicircular periareolar incision for the treatment of gynecomastia.

    Science.gov (United States)

    Esme, Danielle L; Beekman, Werner H; Hage, J Joris; Nipshagen, Martine D

    2007-12-01

    Of the wide range of excisional and liposuction techniques used to correct gynecomastia, so far, no single one was suitable for all grades of gynecomastia. We introduce ultrasonic-assisted liposuction (UAL) combined with conventional liposuction and partial gland resection without skin excision as the standard surgical technique for all such grades. Twenty-eight men (aged 17 to 80 years) were consecutively treated from March 2004 through April 2006 for grade Ia (n = 3), Ib (n = 2), IIa (n = 6), IIb (n = 6), III (n = 8), or IV (n = 3) gynecomastia. Their characteristics and the outcome of surgery were retrospectively assessed. A mean of 848 mL (range, 300 to 1400 mL) of liquefied breast tissue was aspirated, and 31 g (range, 3 to 180 g) of fibroglandular tissue were excised per breast. No immediate or delayed adjuvant skin reduction was needed in any of the patients. Moderate postoperative ecchymosis was observed in 2 patients, but no complications were encountered in this series. The cosmetic outcome was good to excellent in all. UAL in combination with gland resection through a minimal caudal semicircular periareolar incision and conventional liposuction effectively corrects all grades of gynecomastia. This combination has little morbidity, requires no skin excision, and leads to uniformly good esthetic results.

  4. Accuracy of CT-guided joint aspiration in patients with suspected infection status post-total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Tomas, Xavier; Garcia-Diez, Ana Isabel; Pomes, Jaime [Universidad de Barcelona, Department of Radiology, Hospital Clinic, Barcelona (Spain); Bori, Guillem; Garcia, Sebastian; Gallart, Xavier; Martinez, Juan Carlos; Riba, Josep [Universidad de Barcelona, Department of Orthopaedics, Hospital Clinic, Barcelona (Spain); Soriano, Alex; Mensa, Josep [Universidad de Barcelona, Department of Infectious Diseases, Hospital Clinic, Barcelona (Spain); Rios, Jose [Statistical Unit de Suport a la Estadistica I Metodologia IDIBAPS, Barcelona (Spain); Almela, Manel [Universidad de Barcelona, Department of Microbiology, Hospital Clinic, Barcelona (Spain)

    2011-01-15

    To determine the accuracy of guided computed tomography aspiration in the detection of septic hip prosthesis before surgery. Sixty-three patients (35 women and 28 men; age range, 29-86 years; mean age, 71 years) with clinically suspected septic hip prosthesis were prospectively studied with independent review board (IRB) approval. Volume and microbiological cultures of aspirated fluid and several computed tomography imaging findings such as periprosthetic fluid collections, prosthetic acetabular malposition, and heterotopic ossification were analyzed. All patients underwent revision surgery and infection was finally diagnosed in 33 patients. Statistical comparative analysis was performed comparing computed tomography aspiration and surgical findings (95% CI; level of significance at P = 0.05 two-sided) with 70% sensitivity, 100% specificity, 84% accuracy, 100% positive predictive value, and 75% negative predictive value. Using Fisher's exact test, the presence of periprosthetic fluid collections (P = 0.001), prosthetic acetabular malposition (P = 0.025) and aspirated fluid volume (P = 0.009) were significantly higher in infected than in non-infected prostheses, whereas heterotopic ossification was not (P = 0.429). Computed tomography aspiration is accurate to preoperatively diagnose septic hip prosthesis on the basis of volume and bacterial cultures of aspirated joint fluid. Furthermore, imaging findings such as periprosthetic fluid collections and prosthetic acetabular malposition strongly suggest infected prosthesis. (orig.)

  5. Accuracy of CT-guided joint aspiration in patients with suspected infection status post-total hip arthroplasty

    International Nuclear Information System (INIS)

    Tomas, Xavier; Garcia-Diez, Ana Isabel; Pomes, Jaime; Bori, Guillem; Garcia, Sebastian; Gallart, Xavier; Martinez, Juan Carlos; Riba, Josep; Soriano, Alex; Mensa, Josep; Rios, Jose; Almela, Manel

    2011-01-01

    To determine the accuracy of guided computed tomography aspiration in the detection of septic hip prosthesis before surgery. Sixty-three patients (35 women and 28 men; age range, 29-86 years; mean age, 71 years) with clinically suspected septic hip prosthesis were prospectively studied with independent review board (IRB) approval. Volume and microbiological cultures of aspirated fluid and several computed tomography imaging findings such as periprosthetic fluid collections, prosthetic acetabular malposition, and heterotopic ossification were analyzed. All patients underwent revision surgery and infection was finally diagnosed in 33 patients. Statistical comparative analysis was performed comparing computed tomography aspiration and surgical findings (95% CI; level of significance at P = 0.05 two-sided) with 70% sensitivity, 100% specificity, 84% accuracy, 100% positive predictive value, and 75% negative predictive value. Using Fisher's exact test, the presence of periprosthetic fluid collections (P = 0.001), prosthetic acetabular malposition (P = 0.025) and aspirated fluid volume (P = 0.009) were significantly higher in infected than in non-infected prostheses, whereas heterotopic ossification was not (P = 0.429). Computed tomography aspiration is accurate to preoperatively diagnose septic hip prosthesis on the basis of volume and bacterial cultures of aspirated joint fluid. Furthermore, imaging findings such as periprosthetic fluid collections and prosthetic acetabular malposition strongly suggest infected prosthesis. (orig.)

  6. AngioVac Aspiration for Paradoxical Emboli Protection through a Fenestrated Fontan During Central Venous Thrombus Manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Al-Hakim, Ramsey, E-mail: ralhakim@mednet.ucla.edu [University of California, Department of Radiology, Division of Interventional Radiology (United States); Patel, Komal, E-mail: kdpatel@mednet.ucla.edu [University of California, Department of Anesthesiology, Division of Cardiothoracic Anesthesiology (United States); Moriarty, John M., E-mail: jmoriarty@mednet.ucla.edu [University of California, Department of Radiology, Division of Interventional Radiology (United States)

    2015-06-15

    This case reports describes a 39-year-old female with a history of surgically repaired hypoplastic left heart syndrome who presented with a left peripherally inserted central catheter (PICC) with associated large volume subclavian and brachiocephalic vein thrombus. Due to the presence of a right-to-left shunt via a fenestrated Fontan, there was clinical concern for a paradoxical embolism during removal of the PICC. The AngioVac aspiration system was successfully utilized to aspirate thromboemboli from the level of the proximal Glenn shunt during manipulation and removal of the PICC. This is the first reported case to demonstrate the safe and effective use of the AngioVac aspiration system for protection of paradoxical emboli through a cardiac right-to-left shunt during a procedure at high risk for thromboembolism.

  7. Ultrasonic testing

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sung Jin [Sungkwunkwan Univ., Seoul (Korea, Republic of); Jeong, Hyun Jo [Wonkwang Univ., Iksan (Korea, Republic of)

    2004-02-15

    For the proper performance of ultrasonic testing of steel welded joints, and anisotropic material it is necessary to have sound understanding on the underlying physics. To provide such an understanding, it is beneficial to have simulation tools for ultrasonic testing. In order to address such a need, we develop effective approaches to simulate angle beam ultrasonic testing with a personal computer. The simulation is performed using ultrasonic measurement models based on the computationally efficient multi-Gaussian beams. This reach will describe the developed ultrasonic testing models together with the experimental verification of their accuracy.

  8. ASPIRE-to-Excellence Academy

    Directory of Open Access Journals (Sweden)

    Simon Drees

    2016-07-01

    Full Text Available The ASPIRE-to-Excellence Academy was recently founded at the 2015 Association for Medical Education in Europe (AMEE conference in Glasgow. The academy is new pillar of the ASPIRE-to-Excellence initiative by AMEE, which aims at promoting and encouraging medical schools in achieving excellence in the categories of assessment, student engagement, social accountability or faculty development. The Academy panel consists of the members of the ASPIRE Board and representatives from schools which have been recognised with an ASPIRE-to-excellence award in one or more of the categories. Major goal of the ASPIRE-to-Excellence Academy is to foster collaboration between excellent medical schools and to allow them to exchange experiences and Best Practices. The Academy members are organising workshops and symposia at international conferences to inform medical schools about the ASPIRE-to-Excellence programme and the areas for recognition in excellence as well as to support medical school in preparing their applications.

  9. Multiple squamous cells in thyroid fine needle aspiration: Friends or foes?

    Science.gov (United States)

    Gage, Heather; Hubbard, Elizabeth; Nodit, Laurentia

    2016-08-01

    Abundant squamous cells are rarely encountered in thyroid FNA with only few case reports noted in the literature. Their presence and cytologic features may pose a diagnostic dilemma and challenges for proper classification and follow-up. We intend to gain more insight into the frequency of this finding and its clinical significance. Our electronic records were searched over 16 years to reveal 15 thyroid FNAs with abundant squamous cells. The available cytology and surgical resection slides were reviewed and radiologic records and clinical follow-up was documented. Only 15 out of 8811 thyroid FNAs from our department contained predominantly squamous cells (0.17%) of which two were interpreted as nondiagnostic, four as atypical, eight as benign, and one malignant. Surgical follow-up was available in eight cases only with benign lesions representing the majority of the cases (squamous metaplasia in Hashimoto thyroiditis, benign epidermoid/branchial cleft or thyroglossal duct cysts, and one case squamous cell carcinoma). The cases without surgical resection were stable on subsequent ultrasound studies. Thyroid aspirates with predominance of squamous cells cannot be classified in the current Bethesda categories. Even when interpreted as atypical or equivocal, the squamous cells present in our small case series were mostly benign. The only malignant case was easily identified cytologically because of its higher degree of differentiation. The most common pitfall for atypical squamous cells in these aspirates was squamous metaplasia in the setting of Hashimoto thyroiditis and degenerative changes. Diagn. Cytopathol. 2016;44:676-681. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. Improved histopathological evaluation of gliomas using tissue fragments obtained by ultrasonic aspiration

    DEFF Research Database (Denmark)

    Neckelmann, K; Kristensen, B W; Schrøder, H D

    2004-01-01

    included in the biopsy removed for peroperative frozen section investigation. When the slides with Sonocut tissue fragments were analyzed, the probability of making the most malignant diagnosis increased from 81.3% - 99.1%, when slides from 1 - 5 paraffin blocks were analyzed, respectively. When subgroups...... of small, medium and big tumors were analyzed, it was found that only 2 paraffin blocks from small tumors need to be prepared to reach 98.3% probability of making the most malignant diagnosis, whereas 5 paraffin blocks from big tumors need to be prepared to reach a 96.8% probability. In conclusion......, the study shows that a limited amount of Sonocut ultrasonic tissue fragments improve the diagnostic evaluation of gliomas. These tissue fragments therefore must not be discarded. Only few paraffin blocks need to be prepared to reach close to 100% probability of making the most malignant diagnosis, reducing...

  11. Poverty and aspirations failure

    NARCIS (Netherlands)

    Dalton, P.S.; Ghosal, S.; Mani, A.

    We develop a theoretical framework to study the psychology of poverty and ‘aspirations failure’, defined as the failure to aspire to one’s own potential. In our framework, rich and the poor persons share the same preferences and same behavioral bias in setting aspirations. We show that poverty can

  12. Clinical study using a new phacoemulsification system with surgical intraocular pressure control.

    Science.gov (United States)

    Solomon, Kerry D; Lorente, Ramón; Fanney, Doug; Cionni, Robert J

    2016-04-01

    To compare cumulative dissipated energy (CDE), aspiration fluid used, and aspiration time during phacoemulsification cataract extraction using 2 surgical configurations. Two clinical sites in the United States and 1 in Spain. Prospective randomized clinical case series. For each patient, the first eye having surgery was randomized to the active-fluidics configuration (Centurion Vision System with Active Fluidics, 0.9 mm 45-degree Intrepid Balanced tip, and 0.9 mm Intrepid Ultra infusion sleeve) or the gravity-fluidics configuration (Infiniti Vision System with gravity fluidics, 0.9 mm 45-degree Mini-Flared Kelman tip, and 0.9 mm Ultra infusion sleeve). Second-eye surgery was completed within 14 days after first-eye surgery using the alternate configuration. The CDE, aspiration fluid used, and aspiration time were compared between configurations, and adverse events were summarized. Patient demographics and cataract characteristics were similar between configurations (100 per group). The CDE was significantly lower with the active-fluidics configuration than with the gravity-fluidics configuration (mean ± standard error, 4.32 ± 0.28 percent-seconds) (P < .001). The active-fluidics configuration used significantly less aspiration fluid than the gravity-fluidics configuration (mean 46.56 ± 1.39 mL versus 52.68 ± 1.40 mL) (P < .001) and required significantly shorter aspiration time (mean 151.9 ± 4.1 seconds versus 167.6 ± 4.1 seconds) (P < .001). No serious ocular adverse events related to the study devices or device deficiencies were observed. Significantly less CDE, aspiration fluid used, and aspiration time were observed with the active-fluidics configuration than with the gravity-fluidics configuration, showing improved surgical efficiency. Drs. Solomon and Cionni are consultants to Alcon Research, Ltd., and received compensation for conduct of the study. Dr. Lorente received compensation for clinical work in the study. Mr. Fanney is an

  13. Axillary fine needle aspiration cytology for pre-operative staging of patients with screen-detected invasive breast carcinoma.

    LENUS (Irish Health Repository)

    Hayes, Brian D

    2012-02-01

    INTRODUCTION: Fine needle aspiration cytology (FNAC) of radiologically abnormal axillary lymph nodes in patients with breast cancer can identify patients suitable for primary axillary clearance (AC) rather than sentinel node biopsy, enabling surgical axillary staging by a single operation. This study assessed the accuracy of FNAC in predicting positive axillary lymph nodes. METHODS: 161 patients with screen-detected invasive carcinoma and who had pre-operative FNAC of a radiologically abnormal axillary lymph node were identified from two screening units, The axillary FNAC reports were correlated with sentinel node biopsy and AC reports, and sensitivity, specificity, positive (PPV) and negative (NPV) predictive values were calculated. RESULTS: FNAC had a moderate sensitivity (66.3%) and NPV (71.8%), and a high specificity (98.7%) and PPV (98.3%). Most patients (86%) had a single axillary operation. The sensitivity was highest in grade 3 (81.8%) and ductal type (77.8%) tumours. The sensitivity was lower in tumours of special type (34.8%), grade 1 tumours (50%) and those without lymphovascular invasion (LVI) (55.9%). The NPV was highest in pT1 (86.7%) and in grade 1 (84.5%) tumours, and lowest (44%) in tumours with LVI. The PPV was 100% in grade 1 and 3 tumours, stage pT2 and pT3 tumours and those without LVI, and was high (>96%) in all other groups. In lymph-node-positive patients, the mean number of lymph nodes involved was higher in the case of a positive (6.4) than negative FNAC (4.4). CONCLUSIONS: FNAC of ultrasonically abnormal axillary lymph nodes achieved surgical staging by a single operation in most patients with screen-detected invasive breast carcinoma, with moderate sensitivity and high specificity.

  14. Clinical surgical and pathological characterization of nodular thyroid disease

    International Nuclear Information System (INIS)

    Gonzalez Mendoza, Dayanis Ceila; Rodriguez Valdes, Adriana; Bejerano Garcia, Ramiro Julio

    2012-01-01

    Nodular thyroid disease is a worrisome endocrine problem due to its association with cancer. To characterize patients hospitalized with this condition according to clinical surgical and pathological aspects, as well as to determine the effectiveness of the cytology by fine-needle aspiration biopsy for diagnosis

  15. Sequential voluntary cough and aspiration or aspiration risk in Parkinson's disease.

    Science.gov (United States)

    Hegland, Karen Wheeler; Okun, Michael S; Troche, Michelle S

    2014-08-01

    Disordered swallowing, or dysphagia, is almost always present to some degree in people with Parkinson's disease (PD), either causing aspiration or greatly increasing the risk for aspiration during swallowing. This likely contributes to aspiration pneumonia, a leading cause of death in this patient population. Effective airway protection is dependent upon multiple behaviors, including cough and swallowing. Single voluntary cough function is disordered in people with PD and dysphagia. However, the appropriate response to aspirate material is more than one cough, or sequential cough. The goal of this study was to examine voluntary sequential coughing in people with PD, with and without dysphagia. Forty adults diagnosed with idiopathic PD produced two trials of sequential voluntary cough. The cough airflows were obtained using pneumotachograph and facemask and subsequently digitized and recorded. All participants received a modified barium swallow study as part of their clinical care, and the worst penetration-aspiration score observed was used to determine whether the patient had dysphagia. There were significant differences in the compression phase duration, peak expiratory flow rates, and amount of air expired of the sequential cough produced by participants with and without dysphagia. The presence of dysphagia in people with PD is associated with disordered cough function. Sequential cough, which is important in removing aspirate material from large- and smaller-diameter airways, is also impaired in people with PD and dysphagia compared with those without dysphagia. There may be common neuroanatomical substrates for cough and swallowing impairment in PD leading to the co-occurrence of these dysfunctions.

  16. Ultrasonic signature

    International Nuclear Information System (INIS)

    Borloo, E.; Crutzen, S.

    1974-12-01

    The unique and tamperproof identification technique developed at Ispra is based on ultrasonic Non-Destructive-Techniques. Reading fingerprints with ultrasonic requires high reproducibility of standard apparatus and transducers. The present report gives an exhaustive description of the ultrasonic technique developed for identification purposes. Different applications of the method are described

  17. Scintigraphic diagnosis of silent aspiration following double-sided lung transplantation; Szintigraphischer Nachweis einer stillen Aspiration nach beidseitiger Lungentransplantation

    Energy Technology Data Exchange (ETDEWEB)

    Toenshoff, G. [Kiel Univ. (Germany). Klinik fuer Nuklearmedizin; Stock, U. [Kiel Univ. (Germany). Klinik fuer Herz- und Gefaesschirurgie; Bohuslavizki, K.H. [Kiel Univ. (Germany). Klinik fuer Nuklearmedizin; Brenner, W. [Kiel Univ. (Germany). Klinik fuer Nuklearmedizin; Costard-Jaeckle, A. [Kiel Univ. (Germany). Klinik fuer Herz- und Gefaesschirurgie; Cremer, J. [Kiel Univ. (Germany). Klinik fuer Herz- und Gefaesschirurgie; Clausen, M. [Kiel Univ. (Germany). Klinik fuer Nuklearmedizin

    1996-08-01

    We present a case of a 25 year old patient who underwent double-sided lung transplantation and suffered from recurrent pneumonia. Silent aspiration was suspected clinically. Aspiration was proved by scintigraphy enabling to discriminate between direct oro-pulmonal aspiration and aspiration after gastro-esophageal reflux. (orig.) [Deutsch] Vorgestellt wird der Fall einer 25jaehrigen Patientin nach beidseitiger Lungentransplantation und rezidivierenden Pneumonien. Klinisch bestand der Verdacht auf eine stille Aspiration. Szintigraphisch gelang sowohl der Aspirationsnachweis als auch eine Differenzierung hinsichtlich der Genese: Direkte oro-pulmonale Aspiration versus Aspiration nach gastrooesophagealem Reflux. (orig.)

  18. Ultrasonic horn design for ultrasonic machining technologies

    Directory of Open Access Journals (Sweden)

    Naď M.

    2010-07-01

    Full Text Available Many of industrial applications and production technologies are based on the application of ultrasound. In many cases, the phenomenon of ultrasound is also applied in technological processes of the machining of materials. The main element of equipments that use the effects of ultrasound for machining technology is the ultrasonic horn – so called sonotrode. The performance of ultrasonic equipment, respectively ultrasonic machining technologies depends on properly designed of sonotrode shape. The dynamical properties of different geometrical shapes of ultrasonic horns are presented in this paper. Dependence of fundamental modal properties (natural frequencies, mode shapes of various sonotrode shapes for various geometrical parameters is analyzed. Modal analyses of the models are determined by the numerical simulation using finite element method (FEM design procedures. The mutual comparisons of the comparable parameters of the various sonotrode shapes are presented.

  19. [Piezosurgery for surgically assisted rapid maxillary expansion under local anesthesia].

    Science.gov (United States)

    Sun, Hao; Li, Biao; Sun, Hao; Liu, Zhixu; Wang, Xudong

    2014-08-01

    This study evaluates piezosurgery for surgically assisted rapid maxillary expansion (SARME) under local anesthesia. SARME was performed on adults with maxillary transverse deficiency under local anesthesia with a piezosurgical device. Fourteen patients (six males and eight females) underwent lateral maxillary osteotomies, midpalatal osteotomies, and bilateral pterygomaxillary disjunction. The feelings of patients during the operation were determined through questionnaires. All patients underwent SARME in the out-patient operating room. The surgical procedures were completed under local anesthesia. All patients exhibited satisfactory tolerance. Ultrasonic bone-cutting surgery was recently introduced as a feasible alternative to the conventional tools of cranio-maxillofacial surgery for its technical characteristics of precision and safety. The device used was unique in that cutting action occurred when the tool was employed on mineralized tissues, but stoped on soft tissues. The results of the questionnaires showed that eight (57.14%) patients felt a mild sensation of ultrasonic vibration, tweleve (85.7 1%) felt mild tolerable pain and tooth soreness during surgery, and eleven (78.57%) felt little fear and hardly heard the ultrasonic sound. Preoperative and postoperative six months later measurements showed an evident effect of expansion. Piezosurgery enabled patients to undergo all the steps of SARME under local anesthesia, but more cases and longer follow-up are needed to verif ' the results.

  20. Global curriculum in surgical oncology.

    Science.gov (United States)

    Are, C; Berman, R S; Wyld, L; Cummings, C; Lecoq, C; Audisio, R A

    2016-06-01

    The significant global variations in surgical oncology training paradigms can have a detrimental effect on tackling the rising global cancer burden. While some variations in training are essential to account for the differences in types of cancer and biology, the fundamental principles of providing care to a cancer patient remain the same. The development of a global curriculum in surgical oncology with incorporated essential standards could be very useful in building an adequately trained surgical oncology workforce, which in turn could help in tackling the rising global cancer burden. The leaders of the Society of Surgical Oncology and European Society of Surgical Oncology convened a global curriculum committee to develop a global curriculum in surgical oncology. A global curriculum in surgical oncology was developed to incorporate the required domains considered to be essential in training a surgical oncologist. The curriculum was constructed in a modular fashion to permit flexibility to suit the needs of the different regions of the world. Similarly, recognizing the various sociocultural, financial and cultural influences across the world, the proposed curriculum is aspirational and not mandatory in intent. A global curriculum was developed which may be considered as a foundational scaffolding for training surgical oncologists worldwide. It is envisioned that this initial global curriculum will provide a flexible and modular scaffolding that can be tailored by individual countries or regions to train surgical oncologists in a way that is appropriate for practice in their local environment. Copyright © 2016 Society of Surgical Oncology, European Society of Surgical Oncology. Published by Elsevier Ltd.. All rights reserved.

  1. INITIAL EXPERIENCE WITH ENDOSCOPIC ULTRASOUND-GUIDED FINE NEEDLE ASPIRATION OF RENAL MASSES: indications, applications and limitations

    Directory of Open Access Journals (Sweden)

    Renata Nobre MOURA

    2014-12-01

    Full Text Available Context Tissue sampling of renal masses is traditionally performed via the percutaneous approach or laparoscopicaly. The utility of endoscopic ultrasound to biopsy renal lesions it remains unclear and few cases have been reported. Objectives To evaluate the feasibility and outcome of endoscopic ultrasound fine needle aspiration of renal tumors. Methods Consecutive subjects undergoing attempted endoscopic ultrasound fine needle aspiration of a kidney mass after evaluation with computerized tomography or magnetic resonance. Results Ten procedures were performed in nine male patients (median age 54.7 years on the right (n = 4 and left kidney (n = 4 and bilaterally (n = 1. Kidney masses (median diameter 55 mm ; range 13-160 mm were located in the upper pole (n = 3, the lower pole (n = 2 and the mesorenal region (n = 3. In two cases, the mass involved more than one kidney region. Surgical resection confirmed renal cell carcinoma in six patients in whom pre-operative endoscopic ultrasound fine needle aspiration demonstrated renal cell carcinoma. No complications were reported. Conclusions Endoscopic ultrasound fine needle aspiration appears as a safe and feasible procedure with good results and minimal morbidity.

  2. Fine needle aspiration cytology versus frozen section in branchial cleft cysts.

    Science.gov (United States)

    Begbie, F; Visvanathan, V; Clark, L J

    2015-02-01

    Branchial cleft cysts occur because of a failure of involution of the second branchial cleft. However, as well-differentiated squamous cell carcinoma can mimic branchial cleft cysts, there is a lack of consensus on the appropriate management of cystic neck lumps. To report our experience of fine needle aspiration cytology and frozen section examination in the management of cystic neck lumps. Retrospective case note review of patients managed in the Southern General Hospital, Scotland, UK. The sensitivity of fine needle aspiration cytology and frozen section for detecting branchial cleft cysts was 75 per cent and 100 per cent respectively. Two patients who did not undergo intra-operative frozen section examination were either over- or under-treated, which is discussed. Adult patients subjected to surgical excision of a suspected branchial cyst should undergo intra-operative frozen section analysis regardless of clinical suspicion for malignancy. This part of management is critical to ensure patients are offered appropriate treatment.

  3. Aspiration pneumonia: a review of modern trends.

    Science.gov (United States)

    DiBardino, David M; Wunderink, Richard G

    2015-02-01

    The purpose was to describe aspiration pneumonia in the context of other lung infections and aspiration syndromes and to distinguish between the main scenarios commonly implied when the terms aspiration or aspiration pneumonia are used. Finally, we aim to summarize current evidence surrounding the diagnosis, microbiology, treatment, risks, and prevention of aspiration pneumonia. Medline was searched from inception to November 2013. All descriptive or experimental studies that added to the understanding of aspiration pneumonia were reviewed. All studies that provided insight into the clinical aspiration syndromes, historical context, diagnosis, microbiology, risk factors, prevention, and treatment were summarized within the text. Despite the original teaching, aspiration pneumonia is difficult to distinguish from other pneumonia syndromes. The microbiology of pneumonia after a macroaspiration has changed over the last 60 years from an anaerobic infection to one of aerobic and nosocomial bacteria. Successful antibiotic therapy has been achieved with several antibiotics. Various risks for aspiration have been described leading to several proposed preventative measures. Aspiration pneumonia is a disease with a distinct pathophysiology. In the modern era, aspiration pneumonia is rarely solely an anaerobic infection. Antibiotic treatment is largely dependent on the clinical scenario. Several measures may help prevent aspiration pneumonia. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Autoaspiration versus manual aspiration in transbronchial needle aspiration in diagnosis of intrathoracic lymphadenopathy.

    Science.gov (United States)

    Boonsarngsuk, Viboon; Pongtippan, Atcharaporn; Juthakarn, Sabaitip; Boonsarngsuk, Wison; Kurimoto, Noriaki

    2009-10-01

    Traditionally, aspiration with high negative pressure is recommended to obtain a specimen in transbronchial needle aspiration (TBNA). Undeniably, however, the assistant experiences difficulty in the generation of the negative pressure and precise control of the syringe while performing the procedure. To evaluate the effectiveness of the autoaspiration method created by our plunger lock in comparison with the conventional manual aspiration in the diagnosis of intrathoracic lymphadenopathy by TBNA. A prospective study was conducted on all patients referred for diagnostic TBNA of enlarged intrathoracic lymph nodes. Both automatic and manual aspiration techniques were performed after the needle had been completely inserted into the nodes. The diagnostic yield and the numbers of diagnostic cells or benign lymphoid cells obtained by each technique were compared in the same node. A total of 31 intrathoracic lymph nodes in 24 patients were prospectively studied. Twenty-four nodes (77.4%) were malignancies whereas 7 nodes (22.6%) were benign disease. Adequate lymph node samples were obtained in 30 targets (96.8%), and TBNA revealed definite diagnosis for 25 nodes (80.6%). Both aspiration techniques showed exactly the same diagnostic yield. However, the autoaspiration technique provided significantly more adequate samples than manual aspiration techniques did (P=0.003). The autoaspiration method using our plunger lock was superior to the manual method in obtaining the numbers of adequate samples in TBNA procedures.

  5. [Study on pulmonary lesions in which nontuberculous mycobacteria were detected by percutaneous aspiration--a proposal to add "culture positivity of percutaneous aspiration material" to the bacteriological diagnostic criteria of pulmonary nontuberculous mycobacterial diseases].

    Science.gov (United States)

    Nakahara, Yasuharu; Mochizuki, Yoshiro; Kawamura, Tetsuji; Sasaki, Shin; Morimoto, Akie; Mizumori, Yasuyuki; Tsukamoto, Hiroaki; Watanabe, Etsuko; Yokoyama, Toshihide

    2013-03-01

    deterioration was seen in the other 2. Aspiration from solitary small cavitary lesions showed a relatively high number of NTM colonies. Pneumothorax was the only complication of the aspiration procedure. If the diagnostic criteria for pulmonary NTM diseases include positive culture in percutaneous aspiration material, the diagnosis of solitary nodular NTM lesions would become easier; at present, these lesions are often diagnosed only upon surgical resection. Further, clinical studies on the possibility of spontaneous shrinkage of the solitary lesion and the value of its medical treatment would be promoted. Aspiration can easily differentiate NTM disease from pulmonary abscess or fungal infection in patients with a solitary lesion or small cavity.

  6. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    Science.gov (United States)

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  7. Aspirations of Latina adolescent suicide attempters

    OpenAIRE

    Hausmann-Stabile, Carolina; Gulbas, Lauren; Zayas, Luis H.

    2013-01-01

    Parents’ aspirations and expectations are communicated to their offspring. Children internalize their parents’ aspirations and accept some of the expectations while rejecting others, all part of the developmental process and identity-consolidation. When the aspirations and expectations of youth and parents are incongruent, the outcomes in youths’ behavior can be deleterious, such as when adolescents manifest suicidal behaviors. We examined aspirations expressed by 12 Latina adolescent suicide...

  8. Thyroid Fine-Needle Aspiration Cytology Practice in Korea

    Directory of Open Access Journals (Sweden)

    Yoon Jin Cha

    2017-11-01

    Full Text Available We reviewed the current status of thyroid fine-needle aspiration cytology (FNAC in Korea. Thyroid aspiration biopsy was first introduced in Korea in 1977. Currently, radiologists aspirate the thyroid nodule under the guidance of ultrasonography, and cytologic interpretation is only legally approved when a cytopathologist makes the diagnosis. In 2008, eight thyroid-related societies came together to form the Korean Thyroid Association. The Korean Society for Cytopathology and the endocrine pathology study group of the Korean Society for Pathologists have been updating the cytologic diagnostic guidelines. The Bethesda System for Reporting Thyroid Cytopathology was first introduced in 2009, and has been used by up to 94% of institutions by 2016. The average diagnosis rates are as follows for each category: I (12.4%, II (57.9%, III (10.4%, IV (2.9%, V (3.7%, and VI (12.7%. The malignancy rates in surgical cases are as follows for each category: I (28.7%, II (27.8%, III (50.6%, IV (52.3%, V (90.7%, and VI (100.0%. Liquid-based cytology has been used since 2010, and it was utilized by 68% of institutions in 2016. The categorization of thyroid lesions into “atypia of undetermined significance” or “follicular lesion of undetermined significance” is necessary to draw consensus in our society. Immunocytochemistry for galectin-3 and BRAF is used. Additionally, a molecular test for BRAF in thyroid FNACs is actively used. Core biopsies were performed in only 44% of institutions. Even the institutions that perform core biopsies only perform them for less than 3% of all FNACs. However, only 5% of institutions performed core biopsies up to three times more than FNAC.

  9. Ultrasonic inspection

    International Nuclear Information System (INIS)

    Satittada, Gannaga

    1984-01-01

    Ultrasonic inspection is one of the most widely used methods for nondestructive inspection. The beam of high-frequency sound wave, ultrasonic wave, is introduced into the material. It travels through the material with some attendant loss of energy and can be reflected at interfaces. The reflected beam is detected and analyzed. Ultrasonic inspection is used to detect flaws in metal parts as well as in welded, brazed and bonded joints during research work and developing production and service. It is also used to detect and locate porosity, pipe, and flakes. In addition, it can be used for the measurement of metal thickness. Ultrasonic inspection is therefore used for quality control and material inspection in all major industries

  10. Lens subluxation grading system: predictive value for ectopia lentis surgical outcomes

    Directory of Open Access Journals (Sweden)

    Mauro Waiswol

    2009-03-01

    Full Text Available Objective: To present a classification system to grade ectopia lentis and to assess its usefulness as a predictor for surgical outcomes. Methods: Fifty-one eyes of 28 patients with either simple (19 patients or Marfan syndrome-associated ectopia lentis (nine patients with variable degrees of subluxation were operated on. Lens subluxation intensity was graded according to the lens subluxation grading system (LSGS from grade 1 (lens on the whole pupillary area up to grade 4 (lens absent from the pupillary area. Thirty eyes underwent cataract extraction (“dry” aspiration with endocapsular ring and in-the-bag intraocular lens (IOL implantation. Twenty-one eyes underwent cataract extraction (“dry” aspiration with scleral fixation of the IOL. The predictive value of the LSGS was assessed by analyzing the post-operative outcomes, including visual acuity (VA, endothelial cell loss, and complications for each grade on the grading system. Rresults: Patients were classified into grade 1 (19.6%, grade 2 (51% and grade 3 (29.4%. Post-operative VA was lower for eyes with larger degrees of subluxation. The higher the subluxation grade, the higher the endothelial cell loss, as well as, the frequency of vitreous loss and surgical time. Higher subluxation grades prevented optimal surgical outcomes with endocapsular ring and in-the-bag IOL implantation. Cconclusions: The LSGS provides an estimate of the surgical success of ectopia lentis. Adequate standardization of lens subluxation is crucial for understanding studies dealing with the surgical correction of this disorder.

  11. Surgical approach to TIR3 cytology class A prospective evaluation.

    Science.gov (United States)

    D'Alessandro, Nicola; Fasano, Giovanni Michele; Gilio, Francesco; Iside, Giovanni; Izzo, Maria Lucia; Loffredo, Andrea; Pinto, Margherita; Tramontano, Salvatore; Tramutola, Giuseppe; Citro, Giuseppe

    2014-01-01

    Fine-needle aspiration (FNA) has proven to be a safe and reliable method of investigation of thyroid lesions. Referencing to European classification, the associated risk of malignancy for TIR3, category reserved for aspirates that contain architectural and/or nuclear atypia, is variable in such studies. Aims of study were evaluating safety of surgical approach, assessing perioperative parameters surgically related, and estimating neoplastic rate for TIR3 group. A prospective evaluation of all TIR3 submitted to thyroidectomy was conducted by assessing histopatohologic results between January 2005 and December 2012, considering two categories, positive (neoplastic) and negative (not neoplastic) group. Intraoperative and complication rate was analyzed on TIR3 population. A total of 1514 total thyroidectomy was performed from 2005 to 2012: a total of 148 cases was considered on TIR3 group. Positive cases amounted to 64 (43.2%), 29 of which were carcinoma (19.6% of total population) and 35 of which were adenoma, while negative cases amounted to 84 (56.8%). Sensitivity and specificity of TIR3 as neoplastic screening was 43.2% and 82.1%. A total of 32 linfectomies was performed (21.6% of group). Positive group presented a significant lower mean age than negative group (42.1 vs 56.2 years) TIR3 group represents a various category, with probably different malignancy risk. Our results and neoplasms rate confirmed that surgical option should be gold standard, in order to define atypical pattern and reduce delayed diagnoses. Choice of a second FNA or a imaging monitoring should be adopted for specific condition. Fine-needle aspiration, Thyroidectomy, TIR3, Thyroid cancer.

  12. Tracheobronchial Foreign Body Aspiration: Dental Prosthesis

    Directory of Open Access Journals (Sweden)

    Ataman Köse

    2014-01-01

    Full Text Available It is important to extract foreign bodies for avoiding life-threatening complications. They can lead to death if they are not treated. Different signs and symptoms could occur according to the complete or partial airway obstruction. Foreign body aspiration is a rare incident in adults. The organic foreign materials such as foods are found to be aspirated more commonly and are usually settled in the right bronchial system. However, dental prosthesis and teeth aspirations are rare in literature. In our study, a 52-year-old male patient who had aspirated the front part of his lower dental prosthesis accidentally is presented and the foreign body is extracted by using rigid bronchoscopy. There are many causes of aspiration but dental prosthetic aspirations should be kept in mind during sleep. For this reason, dental apparatus must be taken out while asleep.

  13. Poverty and Aspirations Failure

    NARCIS (Netherlands)

    Dalton, P.S.; Ghosal, S.; Mani, A.

    2011-01-01

    We develop a theoretical framework to study the psychology of poverty and 'aspirations failure'. In our framework, the rich and the poor share the same preferences - and also a behavioral bias in setting aspirations. Greater downside risks imposed by poverty exacerbates the effects of this

  14. Ultrasonic mammography

    International Nuclear Information System (INIS)

    Hueneke, B.

    1982-01-01

    608 women are examined by means of ultrasonic mammography during the period of 1 year. 432 patients were examined with the compound method with the U.I. Octoson, a water tank scanner, and 176 patients with the real time method with a directly connected linear-array-scanner. The following results were obtained at the end of the examination period: In the ultrasonic and also in the X-ray mammogram tumour diameters can be determined with an error rate of +- 30%. In the diagnosing of carcinomas, a significant dependence of the exactness on the sice of the tumour is found for the combination of the five methods tested (clinical examination, X-ray mammography, ultrasonic mammography, thermography, cytology). Classifying the individual methods with regard to their exactness, X-ray mammography ranks in front of ultrasonic mammography. Mastopathic changes in the breast can be screened by means of ultrasonic mammography. The structure of the changes can be determined more exactly than with an X-ray picture which is due to the possibility of differentiating solid and cystic structures. In diagnosing fibro-adenomas and establishing diagnoses on young women with dense gland bodies, ultrasonic mammography is superior to radiology both in the ability of screening a finding of a fibro-adenoma (US=88%, X-ray=75%) and in the possibility of classifying it as ''more benign than malignant''. (orig./MG) [de

  15. A case of laryngeal palsy and persistent aspiration pneumonia following radiotherapy for laryngeal carcinoma

    International Nuclear Information System (INIS)

    Nakao, Kazunari; Tayama, Niro; Mizuno, Masahiro; Niimi, Seiji.

    1997-01-01

    A 80-year-old man developed impairment in his laryngeal movement, vocal fold fixation and severe misdeglutition after radiotherapy for laryngeal carcinoma. Despite of several surgical treatments for aspiration pneumonia, the misdeglutition did not cease because of the stiffness in his larynx until a laryngectomy was finally performed. The resected larynx showed marked fibrosis, and it was considered as a late complication of radiotherapy. The treatment course in this difficult case is discussed. (author)

  16. Ultrasonic physics

    CERN Document Server

    Richardson, E G

    1962-01-01

    Ultrasonic Physics, Second Edition, provides an introduction to the fundamental principles of ultrasonic physics. The book opens with a discussion of the sources of ultrasound. This is followed by separate chapters on the properties and detection of ultrasonic radiation; measurement of propagation constants, i.e., the velocity and absorption, of ultrasound; ultrasound propagation in gases, liquids, and solids; and ultrasound propagation in aerosols, suspensions, and emulsions. The final chapter covers miscellaneous physical and physico-chemical actions, including dispersion and coagulation of

  17. Critical evaluation of fine needle aspiration cytology as a diagnostic technique in bone tumors and tumor-like lesions.

    Science.gov (United States)

    Chakrabarti, Sudipta; Datta, Alok Sobhan; Hira, Michael

    2012-01-01

    Though open surgical biopsy is the procedure of choice for the diagnosis of bone tumors, many disadvantages are associated with this approach. The present study was undertaken to evaluate the role of fine needle aspiration cytology (FNAC) as a diagnostic tool in cases of bony tumors and tumor-like lesions which may be conducted in centers where facilities for surgical biopsies are inadequate. The study population consisted of 51 cases presenting with a skeletal mass. After clinical evaluation, radiological correlation was done to assess the nature and extent of each lesion. Fine needle aspiration was performed aseptically and smears were prepared. Patients subsequently underwent open surgical biopsy and tissue samples were obtained for histopathological examination. Standard statistical methods were applied for analysis of data. Adequate material was not obtained even after repeated aspiration in seven cases, six of which were benign. Among the remaining 44 cases, diagnosis of malignancy was correctly provided in 28 (93.3%) out of 30 cases and categorical diagnosis in 20 (66.67%). Interpretation of cytology was more difficult in cases of benign and tumor-like lesions, with a categorical opinion only possible in seven (50%) cases. Statistical analysis showed FNAC with malignant tumors to have high sensitivity (93.3%), specificity (92.9%) and positive predictive value of 96.6%, whereas the negative predictive value was 86.7%. FNAC should be included in the diagnostic workup of a skeletal tumor because of its simplicity and reliability. However, a definitive pathologic diagnosis heavily depends on compatible clinical and radiologic features which can only be accomplished by teamwork. The cytological technique applied in this study could detect many bone tumors and tumor-like conditions and appears particularly suitable as a diagnostic technique for rural regions of India as other developing countries.

  18. Aspiring to physical health: the role of aspirations for physical health in facilitating long-term tobacco abstinence.

    Science.gov (United States)

    Niemiec, Christopher P; Ryan, Richard M; Deci, Edward L; Williams, Geoffrey C

    2009-02-01

    To assess aspirations for physical health over 18 months. To examine whether maintained importance of aspirations for physical health mediated and/or moderated the effect of an intensive intervention on long-term tobacco abstinence. Participants were randomly assigned to an intervention based on self-determination theory or to community care, and provided data at baseline and at 18 and 30 months post-randomization. Aspirations for physical health were better maintained over 18 months among participants in the intervention (mean change=.05), relative to community care (mean change=-.13), t=2.66, p<.01. Maintained importance of aspirations for physical health partially mediated the treatment condition effects on seven-day point prevalence tobacco abstinence (z'=1.68, p<.01) and the longest number of days not smoking (z'=2.16, p<.01), and interacted with treatment condition to facilitate the longest number of days not smoking (beta=.08, p<.05). Maintained importance of aspirations for physical health facilitated tobacco abstinence. Smokers may benefit from discussing aspirations for physical health within autonomy-supportive interventions. Patients may benefit from discussing aspirations during counseling about therapeutic lifestyle change and medication use.

  19. Brain abscess: surgical experiences of 162 cases

    Directory of Open Access Journals (Sweden)

    Forhad Hossain Chowdhury

    2015-01-01

    Full Text Available Aim: Brain abscess still poses a public health challenge in spite of the advent of modern neurosurgical techniques and antibiotics. Here, we present our surgical experiences and ultimate outcome in the management of brain abscess. Methods: Totally, 162 patients with proved brain abscess who underwent surgical treatment were included in this study. The prospectively recorded data of surgical management of brain abscess and the ultimate outcome (by Glasgow outcome scale were studied retrospectively. Results: Total number of cases was 162, of which 113 were acute pyogenic abscess while 49 were chronic abscess. Among the chronic abscess, 29 were chronic pyogenic abscess, 14 were tubercular, 3 aspergillus, and 3 abscesses were in malignant brain metastases. In acute cases, common clinical features were headache, fever, vomiting, focal deficit and seizure. In chronic abscesses, common clinical features were mild to moderate headache and progressive focal deficit. Seventy-three (45.06% patients had adjacent localized sinus, middle ear or cranial infection. The common predisposing factors included postneurosurgery, postpenetrating injury to brain, chronic suppurative otitis media, and congenital heart disease, infective endocarditis, sinusitis and sub optimum immuno-status. Frontal lobe involved in 30.2% cases, temporal lobe is next to involved. Single time burr hole aspiration in 111 (68.5% cases, two or more times burr hole aspiration were done in 34 (21% cases. Pus culture was negative in 129 (79.62% cases. Total number of death was 22 (13.58% cases. Complete resolution of abscess with complete recovery of preoperative neuro-deficit was seen in 80.86% cases and recovery with major neuro-deficit was observed in 5.55% cases. There is a significant association between Glasgow coma scale (GCS on admission and mortality in brain abscess. Conclusion: In most of the cases, pus culture did not yield growth of any causative organism. Mortality was not

  20. Effect of Ultrasonic Frequency on Lactic Acid Fermentation Promotion by Ultrasonic Irradiation

    Science.gov (United States)

    Shimada, Tadayuki; Ohdaira, Etsuzo; Masuzawa, Nobuyoshi

    2004-05-01

    The authors have been researching the promotion of lactic acid fermentation by ultrasonic irradiation. In the past research, it was proven that ultrasonic irradiation is effective in the process of fermentation, and the production of yoghurt and kefir was promoted. In this study, the effect of the ultrasonic frequency in this fermentation process was examined. In the frequency range of this study, it was found that the action of fermentation promotion was exponentially proportionate to the irradiated ultrasonic frequency.

  1. Making mock-FNA smears from fresh surgical pathology specimens to improve smear preparation technique and to create cytohistological correlation series.

    Directory of Open Access Journals (Sweden)

    Tibor Mezei

    Full Text Available Fine needle aspiration (FNA cytology is a well-established diagnostic method based on the microscopic interpretation of often scant cytological material; therefore, experience, good technique and smear quality are equally important in obtaining satisfactory results.We studied the use of fresh surgical pathology specimens for making so-called mock-FNA smears with the potential of cytohistological correlation. Additionally, we studied how this process aids the improvement of preparation technique and smear quality.Cytological aspirates from 32 fresh biopsy specimens from various sites: lung (20, lymph nodes (6, and breast (6 were obtained, all with a clinical diagnosis of tumor. Aspiration was performed from grossly palpable tumors. 25 G needle and Cameco-type syringe holder was used with minimal or no suction.Unfixed surgical specimens provided sufficient cytological material that resulted in good quality smears. After standard processing of specimens into microscopic sections from paraffin embedded tissues, cytohistological case-series were created. No significant alteration was reported in tissue architecture on hematoxylin-eosin stained sections after the aspiration procedure. A gradual, but steady improvement was observed in smear quality just after a few preparations.Our study proved that surgical specimens may be used as a source of cytological material to create cytohistological correlation studies and also to improve FNA cytology skills. The use of very fine gauge needle (25 G, 0,6 mm diameter during the sampling process does not alter tissue architecture therefore the final histopathological diagnosis is not compromised. We conclude that by using fresh surgical specimens useful cytohistological collections can be created both as a teaching resource and as improving experience.

  2. Electromagnetic ultrasonic guided waves

    CERN Document Server

    Huang, Songling; Li, Weibin; Wang, Qing

    2016-01-01

    This book introduces the fundamental theory of electromagnetic ultrasonic guided waves, together with its applications. It includes the dispersion characteristics and matching theory of guided waves; the mechanism of production and theoretical model of electromagnetic ultrasonic guided waves; the effect mechanism between guided waves and defects; the simulation method for the entire process of electromagnetic ultrasonic guided wave propagation; electromagnetic ultrasonic thickness measurement; pipeline axial guided wave defect detection; and electromagnetic ultrasonic guided wave detection of gas pipeline cracks. This theory and findings on applications draw on the author’s intensive research over the past eight years. The book can be used for nondestructive testing technology and as an engineering reference work. The specific implementation of the electromagnetic ultrasonic guided wave system presented here will also be of value for other nondestructive test developers.

  3. Comparison of the CDC Backpack aspirator and the Prokopack aspirator for sampling indoor- and outdoor-resting mosquitoes in southern Tanzania

    Directory of Open Access Journals (Sweden)

    Mgando Joseph

    2011-06-01

    Full Text Available Abstract Background Resting mosquitoes can easily be collected using an aspirating device. The most commonly used mechanical aspirator is the CDC Backpack aspirator. Recently, a simple, and low-cost aspirator called the Prokopack has been devised and proved to have comparable performance. The following study evaluates the Prokopack aspirator compared to the CDC backpack aspirator when sampling resting mosquitoes in rural Tanzania. Methods Mosquitoes were sampled in- and outdoors of 48 typical rural African households using both aspirators. The aspirators were rotated between collectors and households in a randomized, Latin Square design. Outdoor collections were performed using artificial resting places (large barrel and car tyre, underneath the outdoor kitchen (kibanda roof and from a drop-net. Data were analysed with generalized linear models. Results The number of mosquitoes collected using the CDC Backpack and the Prokopack aspirator were not significantly different both in- and outdoors (indoors p = 0.735; large barrel p = 0.867; car tyre p = 0.418; kibanda p = 0.519. The Prokopack was superior for sampling of drop-nets due to its smaller size. The number mosquitoes collected per technician was more consistent when using the Prokopack aspirator. The Prokopack was more user-friendly: technicians preferred using the it over the CDC backpack aspirator as it weighs considerably less, retains its charge for longer and is easier to manoeuvre. Conclusions The Prokopack proved in the field to be more advantageous than the CDC Backpack aspirator. It can be self assembled using simple, low-cost and easily attainable materials. This device is a useful tool for researchers or vector-control surveillance programs operating in rural Africa, as it is far simpler and quicker than traditional means of sampling resting mosquitoes. Further longitudinal evaluations of the Prokopack aspirator versus the gold standard pyrethrum spray catch for indoor resting

  4. Small intestine aspirate and culture

    Science.gov (United States)

    ... ency/article/003731.htm Small intestine aspirate and culture To use the sharing features on this page, please enable JavaScript. Small intestine aspirate and culture is a lab test to check for infection ...

  5. Testicular fine-needle aspiration for the assessment of intratesticular hormone concentrations

    Directory of Open Access Journals (Sweden)

    Ada P Lee

    2016-01-01

    Full Text Available Measurement of intratesticular sex steroid concentrations in men informs both the development of male hormonal contraceptives and the understanding of male infertility. Given the challenges of using invasive techniques to measure testicular hormone physiology, our group has used a minimally-invasive fine-needle aspiration technique to measure intratesticular hormones in normal healthy men. Herein, we present a post-hoc analysis of the safety and efficacy of testicular fine-needle aspiration (FNA completed as part of six clinical trials. From 2001 through 2011, a total of 404 procedures were conducted among 163 research volunteers, 85.9% of which were successful in obtaining sufficient fluid for the measurement of intratesticular steroid concentrations. Pain was the most common side effect, with 36.8% of procedures associated with moderate procedural pain and 4.7% with severe procedural pain. Postprocedural pain was uncommon and abated within a few days. Mild local bruising occurred with 14.9% of procedures. Two serious adverse events (0.5% required surgical intervention. The risk of an adverse event was not associated with age, body mass index, testicular size, or the volume of fluid aspirated. Testicular FNA to obtain fluid for measurement of intratesticular steroid concentrations frequently causes mild to moderate procedural pain, but serious adverse events occur rarely. Testicular FNA has been instrumental for defining human intratesticular hormone physiology and is a minimally-invasive, safe, effective method for obtaining fluid for research on testicular physiology and pathology.

  6. Neonatal aspiration syndrome due to vernix caseosa

    Energy Technology Data Exchange (ETDEWEB)

    Ohlsson, A.; Najjar, H.; Cumming, W.A.

    1985-02-01

    Fetal aspiration of meconium in amniotic fluid is a well-known cause of respiratory distress in newborn infants. It causes an irregular, coarse, nodular pattern on chest radiographs. Less known is that aspiration of vernix caseoasa causes a similar syncrome. We present a post-mature infant in whom aspiration of vernix caseosa caused respiratory distress, ventilatory difficulty, and radiographic changes essentially the same as aspiration of meconium.

  7. Ultrasonic viewing device

    International Nuclear Information System (INIS)

    Ito, Juro.

    1979-01-01

    Purpose: To improve the safety of reactor operation by enabling to detect the states and positions of fuel assemblies over a wide range with a set of ultrasonic viewing device comprising a rotatable ultrasonic transmitter-receiver and a reflector mounted with an adjustable angle. Constitution: A driving portion for a ultrasonic viewing device is provided to a rotary plug closing the opening of a reactor vessel and a guide pipe suspending below the coolant level is provided to the driving portion. An ultrasonic transmitter-receiver is provided at the end of the holder tube in the guide pipe. A reflector is provided at the upper position of the reactor core so as to correspond to the ultrasonic transmitter-receiver. The ultrasonic transmitter-receiver, positioned by the driving portion, performs horizontal movement for scanning the entire surface of the top of the reactor core, as well as vertical movement covering the gap between the upper mechanism on the reactor and the reactor core, whereby the confirmation for the separation of the control rod and the detection for the states of the reactor core can be conducted by the reflection waves from the reflector. (Moriyama, K.)

  8. [Fine needle aspiration cytology of mammography screening

    DEFF Research Database (Denmark)

    Engvad, B.; Laenkholm, A.V.; Schwartz, Thue W.

    2009-01-01

    INTRODUCTION: In the year 2000 a quality assurance programme for the preoperative breast diagnostics was introduced in Denmark. The programme was based on the "European guidelines for quality assurance in breast cancer screening and diagnosis" where - among other measures - five cytological...... diagnostic classes were introduced. The aim of this study was to evaluate the quality assurance programme in a screening population to determine whether fine needle aspiration cytology (FNAC) as first choice remains a useful tool in the preoperative diagnostics, or if needle core biopsy should be the first...... of 66% of the 783 FNACs had a malignant cytology diagnosis, which in 99% of the cases turned out to be the correct diagnosis. Four lesions were false positives all of which represented benign proliferative breast diseases. The surgical procedures in these cases were either excisional biopsy...

  9. Neonatal aspiration syndrome due to vernix caseosa

    International Nuclear Information System (INIS)

    Ohlsson, A.; Najjar, H.; Cumming, W.A.

    1985-01-01

    Fetal aspiration of meconium in amniotic fluid is a well-known cause of respiratory distress in newborn infants. It causes an irregular, coarse, nodular pattern on chest radiographs. Less known is that aspiration of vernix caseoasa causes a similar syncrome. We present a post-mature infant in whom aspiration of vernix caseosa caused respiratory distress, ventilatory difficulty, and radiographic changes essentially the same as aspiration of meconium. (orig.)

  10. Radial vibration and ultrasonic field of a long tubular ultrasonic radiator.

    Science.gov (United States)

    Shuyu, Lin; Zhiqiang, Fu; Xiaoli, Zhang; Yong, Wang; Jing, Hu

    2013-09-01

    The radial vibration of a metal long circular tube is studied analytically and its electro-mechanical equivalent circuit is obtained. Based on the equivalent circuit, the radial resonance frequency equation is derived. The theoretical relationship between the radial resonance frequency and the geometrical dimensions is studied. Finite element method is used to simulate the radial vibration and the radiated ultrasonic field and the results are compared with those from the analytical method. It is concluded that the radial resonance frequency for a solid metal rod is larger than that for a metal tube with the same outer radius. The radial resonance frequencies from the analytical method are in good agreement with those from the numerical method. Based on the acoustic field analysis, it is concluded that the long metal tube with small wall thickness is superior to that with large wall thickness in producing radial vibration and ultrasonic radiation. Therefore, it is expected to be used as an effective radial ultrasonic radiator in ultrasonic sewage treatment, ultrasonic antiscale and descaling and other ultrasonic liquid handling applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Surgical smoke and ultrafine particles

    Directory of Open Access Journals (Sweden)

    Nowak Dennis

    2008-12-01

    Full Text Available Abstract Background Electrocautery, laser tissue ablation, and ultrasonic scalpel tissue dissection all generate a 'surgical smoke' containing ultrafine ( Methods To measure the amount of generated particulates in 'surgical smoke' during different surgical procedures and to quantify the particle number concentration for operation room personnel a condensation particle counter (CPC, model 3007, TSI Inc. was applied. Results Electro-cauterization and argon plasma tissue coagulation induced the production of very high number concentration (> 100000 cm-3 of particles in the diameter range of 10 nm to 1 μm. The peak concentration was confined to the immediate local surrounding of the production side. In the presence of a very efficient air conditioning system the increment and decrement of ultrafine particle occurrence was a matter of seconds, with accumulation of lower particle number concentrations in the operation room for only a few minutes. Conclusion Our investigation showed a short term very high exposure to ultrafine particles for surgeons and close assisting operating personnel – alternating with longer periods of low exposure.

  12. Bacterial signatures in thrombus aspirates of patients with lower limb arterial and venous thrombosis.

    Science.gov (United States)

    Vakhitov, Damir; Tuomisto, Sari; Martiskainen, Mika; Korhonen, Janne; Pessi, Tanja; Salenius, Juha-Pekka; Suominen, Velipekka; Lehtimäki, Terho; Karhunen, Pekka J; Oksala, Niku

    2018-06-01

    Increasing data supports the role of bacterial inflammation in adverse events of cardiovascular and cerebrovascular diseases. In our previous research, DNA of bacterial species found in coronary artery thrombus aspirates and ruptured cerebral aneurysms were mostly of endodontic and periodontal origin, where Streptococcus mitis group DNA was the most common. We hypothesized that the genomes of S mitis group could be identified in thrombus aspirates of patients with lower limb arterial and deep venous thrombosis. Thrombus aspirates and control blood samples taken from 42 patients with acute or acute-on-chronic lower limb ischemia (Rutherford I-IIb) owing to arterial or graft thrombosis (n = 31) or lower limb deep venous thrombosis (n = 11) were examined using a quantitative real-time polymerase chain reaction to detect all possible bacterial DNA and DNA of S mitis group in particular. The samples were considered positive, if the amount of bacterial DNA in the thrombus aspirates was 2-fold or greater in comparison with control blood samples. In the positive samples the mean difference for the total bacterial DNA was 12.1-fold (median, 7.1), whereas the differences for S mitis group DNA were a mean of 29.1 and a median of 5.2-fold. Of the arterial thrombus aspirates, 57.9% were positive for bacterial DNA, whereas bacterial genomes were found in 75% of bypass graft thrombosis with 77.8% of the prosthetic grafts being positive. Of the deep vein thrombus aspirates, 45.5% contained bacterial genomes. Most (80%) of bacterial DNA-positive cases contained DNA from the S mitis group. Previous arterial interventions were significantly associated with the occurrence of S mitis group DNA (P = .049, Fisher's exact test). This is the first study to report the presence of bacterial DNA, predominantly of S mitis group origin, in the thrombus aspirates of surgical patients with lower limb arterial and deep venous thrombosis, suggesting their possible role in the pathogenesis of

  13. Ultrasonic decontamination robot

    International Nuclear Information System (INIS)

    Patenaude, R.S.

    1984-01-01

    An ultrasonic decontamination robot removes radioactive contamination from the internal surface of the inlet and outlet headers, divider plate, tube sheet, and lower portions of tubes of a nuclear power plant steam generator. A programmable microprocessor controller guides the movement of a robotic arm mounted in the header manway. An ultrasonic transducer having a solvent delivery subsystem through which ultrasonic action is achieved is moved by the arm over the surfaces. A solvent recovery suction tube is positioned within the header to remove solvent therefrom while avoiding interference with the main robotic arm. The solvent composition, temperature, pressure, viscosity, and purity are controlled to optimize the ultrasonic scrubbing action. The ultrasonic transducer is controlled at a power density, frequency, and on-off mode cycle such as to optimize scrubbing action within the range of transducer-to-surface distance and solvent layer thickness selected for the particular conditions encountered. Both solvent and transducer control actions are optimized by the programmable microprocessor. (author)

  14. Aspiration pneumonia in patients with cleft palate

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Hun; Choi, Yo Won; Jeon, Seok Chol; Park, Choong Ki; Uhm, Ki Il [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2003-03-01

    To assess the incidence of aspiration pneumonia in infants with cleft palate and to compare the incidence between complete and incomplete types of cleft palate. A review of medical records revealed 100 infants who had undergone initial surgery to repair cleft palate in our hospital during a recent three-year period. Aspiration pneumonia was defined as the coexistence of pneumonia at chest radiography with a history of frequent choking during feeding. The anatomic distribution of aspiration pneumonia was analyzed, and the incidences of aspiration pneumonia in infants with complete and incomplete cleft palate were compared. Among 100 children, aspiration pneumonia was found in 35 (35%). Those with complete and incomplete cleft palate showed similar incidences of the condition (27 of 70 [39%] vs 8 of 30 [27%], p=0.36). Pneumonia was most commonly seen in the left lower lobe (11 of 35), followed by the right upper and lower lobes. Aspiration pneumonia is frequently associated with infants with cleft palate. There is no statistical difference in the incidence of aspiration pneumonia between the complete and the incomplete cleft palate group.

  15. Aspiration pneumonia in patients with cleft palate

    International Nuclear Information System (INIS)

    Lee, Seung Hun; Choi, Yo Won; Jeon, Seok Chol; Park, Choong Ki; Uhm, Ki Il

    2003-01-01

    To assess the incidence of aspiration pneumonia in infants with cleft palate and to compare the incidence between complete and incomplete types of cleft palate. A review of medical records revealed 100 infants who had undergone initial surgery to repair cleft palate in our hospital during a recent three-year period. Aspiration pneumonia was defined as the coexistence of pneumonia at chest radiography with a history of frequent choking during feeding. The anatomic distribution of aspiration pneumonia was analyzed, and the incidences of aspiration pneumonia in infants with complete and incomplete cleft palate were compared. Among 100 children, aspiration pneumonia was found in 35 (35%). Those with complete and incomplete cleft palate showed similar incidences of the condition (27 of 70 [39%] vs 8 of 30 [27%], p=0.36). Pneumonia was most commonly seen in the left lower lobe (11 of 35), followed by the right upper and lower lobes. Aspiration pneumonia is frequently associated with infants with cleft palate. There is no statistical difference in the incidence of aspiration pneumonia between the complete and the incomplete cleft palate group

  16. Ultrasonic testing device

    International Nuclear Information System (INIS)

    Lawrie, W.E.

    1978-01-01

    The ultrasonic transmitter made of polarized ferroelectric ceramic material (lead zirconate titanate) is arranged in a strip carrier which allows it to be introduced between the fuel elements of a fuel subassembly in a water cooled nuclear reactor. The ultrasonic transmitter is insulated relative to the carrier. The echo of the ra dal ultrasonic pulse is recorded which changes as faulty water filled fuel elements are detected. (RW) [de

  17. [Surgical treatment of diffuse adult orbital lymphangioma: two case studies].

    Science.gov (United States)

    Berthout, A; Jacomet, P V; Putterman, M; Galatoire, O; Morax, S

    2008-12-01

    Orbital lymphangioma is a rare vascular malformation; it is a benign but severe anomaly because of its infiltrative, diffuse, and hemorrhagic nature, and its high morbidity rate. Surgical resection is a real challenge on account of the intricate architecture of the lesion. The authors report their surgical experience concerning two cases of diffuse orbital lymphangioma whose diagnosis was established in adulthood and whose surgical treatment was successful. Two patients presented with adult orbital lymphangioma. Progression was slow during the first decade and then was quickly followed by complications: major exorbitism, compressive optic neuropathy, and corneal exposure. Neuroimaging showed a diffuse and cystic orbital malformation. Surgical resection was performed as completely as possible, in one case with a Krönlein orbitotomy and in the other case only via a conjunctive route. An aspirate drain was put in the orbit for 48 h so as to prevent dead spaces forming after resection, an essential risk factor of hemorrhagic or cystic recurrence. Systemic corticotherapy was administered for the 5 days following surgery. The resection was total in one case and subtotal in the other. The surgical follow-up was uneventful with an excellent aesthetic result and an improvement in visual acuity. After 12 months, no tumoral or hemorrhagic recurrence was noted. The surgical treatment of orbital lymphangiomas is challenging because of their infiltrative nature. In diffuse forms, a complete resection is rarely possible because of the risk of sacrificing visual function. In the two cases reported herein, the resection of the extraconal portion was complete, but the intraconal portion was completely removed only in one case. Using the aspirate drain, negative pressure was maintained in the orbital cavity, preventing the formation of chocolate cysts induced by surgery. Although the clinical result was very satisfying, long-term follow-up is necessary to evaluate recurrence

  18. Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation

    Directory of Open Access Journals (Sweden)

    Xing Wang

    2018-02-01

    Full Text Available In ultrasonic array imaging, 3D ultrasonic wavefields are normally recorded by an ultrasonic piezo array transducer. Its performance is limited by the configuration and size of the array transducer. In this paper, a method based on digital holographic interferometry is proposed to record the 3D ultrasonic wavefields instead of the array transducer, and the measurement system consisting of a pulsed laser, ultrasonic excitation, and synchronization and control circuit is designed. A consecutive sequence of holograms of ultrasonic wavefields are recorded by the system. The interferograms are calculated from the recorded holograms at different time sequence. The amplitudes and phases of the transient ultrasonic wavefields are recovered from the interferograms by phase unwrapping. The consecutive sequence of transient ultrasonic wavefields are stacked together to generate 3D ultrasonic wavefields. Simulation and experiments are carried out to verify the proposed technique, and preliminary results are presented.

  19. Aspiring and Aspiration Shaming: Primary Schooling, English, and Enduring Inequalities in Liberalizing Kerala (India)

    Science.gov (United States)

    Mathew, Leya

    2018-01-01

    This paper analyzes narratives about the radical socio-economic changes accompanying liberalization in India to consider how English-medium schooling is becoming an aspirational resource for non-elite parents. I suggest that aspiring is a practice of ethics that marginalized mothers mobilize to negotiate memories of deprivation and yearnings for…

  20. Thin-needle aspiration biopsy of the prostate.

    Science.gov (United States)

    Koss, L G; Woyke, S; Schreiber, K; Kohlberg, W; Freed, S Z

    1984-05-01

    The authors summarize the current status of thin-needle aspiration biopsy of the prostate and evaluate the accomplishments and limitations of this method of diagnosis. Historical developments, indications, technique, contraindications, complications, cytology of aspirates, diagnostic efficacy of aspirates, and grading of prostatic carcinomas are discussed.

  1. Efficacy of aspiration in amebic liver abscess.

    Science.gov (United States)

    Ghosh, Jayant Kumar; Goyal, Sundeep Kumar; Behera, Manas Kumar; Tripathi, Manish Kumar; Dixit, Vinod Kumar; Jain, Ashok Kumar; Shukla, Ramchandra

    2015-01-01

    Amebic liver abscess (ALA) is a common and serious problem in our country. There are only a few controlled trials on the efficacy and advantages of combination therapy with percutaneous needle aspiration and pharmacotherapy, over pharmacotherapy alone for amebic liver abscess. This study was conducted to compare the efficacy of two different treatment modalities i.e. drug treatment alone vs. drug treatment and aspiration of abscess cavity in patients with small (up to 5 cm) and large (5 cm to 10 cm) size ALA. This is one of the largest single center, prospective, randomized studies comparing the efficacy of aspiration in ALA. (i) Mean body temperature, liver tenderness, total leukocyte count (TLC), serum alanine aminotransferase (ALT) and liver span were significantly decreased in the aspiration group on days 8 and 15 as compared to non-aspiration group especially in large abscess (5 cm to 10 cm). (ii) Abscess cavity maximum diameter decreased significantly in aspiration group on days 8 and 15, and 1 month & 3 months in large abscess (5cm to 10 cm). (i) Needle aspiration along with metronidazole hastens clinical improvement especially in large (5 cm up to 10 cm) cavities in patients with ALA. (ii) Aspiration is safe and no major complications occurred. (iii) Hence, combination therapy should be the first choice especially in large ALA (5 cm to 10 cm).

  2. Water swallow screening test for patients after surgery for head and neck cancer: early identification of dysphagia, aspiration and limitations of oral intake.

    Science.gov (United States)

    Hey, Christiane; Lange, Benjamin P; Eberle, Silvia; Zaretsky, Yevgen; Sader, Robert; Stöver, Timo; Wagenblast, Jens

    2013-09-01

    Patients with head and neck cancer (HNC) are at high risk for oropharyngeal dysphagia (OD) following surgical therapy. Early identification of OD can improve outcomes and reduce economic burden. This study aimed to evaluate the validity of a water screening test using increasing volumes postsurgically for patients with HNC (N=80) regarding the early identification of OD in general, and whether there is a need for further instrumental diagnostics to investigate the presence of aspiration as well as to determine the limitations of oral intake as defined by fiberoptic endoscopic evaluation of swallowing. OD in general was identified in 65%, with aspiration in 49%, silent aspiration in 21% and limitations of oral intake in 56%. Despite a good sensitivity, for aspiration of 100% and for limitations of oral intake of 97.8%, the presented water screening test did not satisfactorily predict either of these reference criteria due to its low positive likelihood ratio (aspiration=2.6; limitations of oral intake=3.1). However, it is an accurate tool for the early identification of OD in general, with a sensitivity of 96.2% and a positive likelihood ratio of 5.4 in patients after surgery for HNC.

  3. Aspiration-related deaths in 57 consecutive patients: autopsy study.

    Directory of Open Access Journals (Sweden)

    Xiaowen Hu

    Full Text Available Aspiration can cause a diverse spectrum of pulmonary disorders some of which can lead to death but can be difficult to diagnose.The medical records and autopsy findings of 57 consecutive patients in whom aspiration was the immediate cause of death at Mayo Clinic (Rochester, MN, USA over a 9-yr period, from January 1 2004 to December 31 2012 were analyzed.The median age at death was 72 years (range, 13-95 years and included 39 (68% males. The most common symptom before death was dyspnea (63% and chest radiography revealed bilateral infiltrates in the majority (81%. Most common precipitating factors for aspiration were depressed consciousness (46% and dysphagia (44%. Aspiration-related syndromes leading to death were aspiration pneumonia in 26 (46%, aspiration pneumonitis in 25 (44%, and large airway obstruction in 6 patients (11%. Aspiration was clinically unsuspected in 19 (33% patients. Antimicrobial therapy had been empirically administered to most patients (90% with aspiration pneumonia and aspiration pneumonitis.We conclude aspiration-related deaths occur most commonly in the elderly with identifiable risks and presenting bilateral pulmonary infiltrates. One-third of these aspiration-related pulmonary syndromes were clinically unsuspected at the time of death.

  4. Ultrasonic unit for line-by-line ultrasonic scanning of bodies

    International Nuclear Information System (INIS)

    Soldner, R.

    1978-01-01

    The ultrasonic unit for medical diagnostics operates by the sectorial scanning principle, which avoids direct coupling of the transducer head to the surface of the body. For this purpose, several transmitter/receiver units (approx. 100) are arranged on a partial ring of a circular arc and the ultrasonic beams, which can be triggered sequentially in time, are directed at a common intersection behind the ultrasonic window of the unit, i.e., outside the unit. A mechanical system is employed to set and adjust the partial ring carrying the transmitter/receiver units. (DG) [de

  5. Acquired myospherulosis secondary to gluteal augmentation on fine needle aspiration cytology: A diagnostic challenge.

    Science.gov (United States)

    Alperstein, Susan; Dilcher, Thomas; Viswanathan, Kartik; Rao, Rema A; Siddiqui, Momin T; Giorgadze, Tamara

    2018-05-01

    A 30-year-old female presented with a three-month history of a multilocular cystic lesion over the lumbosacral spine. Fine-needle aspiration biopsy (FNA) of the lesion was performed at an outside institution, and a cytologic diagnosis, suspicious for chordoma, was rendered. The patient presented for surgical consultation at our institution. Repeat FNA demonstrated an unusual fat-like material. Upon further inquiry, the patient provided a recent history of gluteal contour improvement with fibroadipose tissue implants. A diagnosis of myospherulosis was made with a concurrent surgical pathology correlation. No evidence of chordoma was identified. To date, this is the first reported case of acquired myospherulosis in the context of gluteal contour enhancement and represents an important diagnostic pitfall to consider on cytology preparations. © 2017 Wiley Periodicals, Inc.

  6. Solitary metastatic cancer to the thyroid: a report of five cases with fine-needle aspiration cytology

    Directory of Open Access Journals (Sweden)

    Batoroev Yuri

    2007-01-01

    Full Text Available Abstract Three men and 2 women with ages ranging from 37 to 70 years, clinically and histologically confirmed solitary, palpable metastatic cancers to the thyroid (SMCT and preoperative cytologic investigation of their thyroid lesions by fine-needle aspiration (FNA, were reviewed. Four patients were known to have a solid cancer treated by radical surgery 1 to 4 years prior [1 bronchogenic squamous cell carcinoma, 1 parotid adenoid cystic carcinoma, 1 renal cell carcinoma (RCC and 1 cutaneous melanoma], and 1 patient had no past history of cancer. Direct smears prepared from the patients' thyroid FNAs were fixed in 95% ethanol and stained with the Papanicolaou method. In 3 cases, immunostaining of the aspirated tumor cells with thyroglobulin antibody was performed, and in 1 case an aspiration smear was stained with commercial HMB-45 antibody. A correct cytodiagnosis of metastatic cancer to the thyroid was made in all 5 cases. In 1 patient the thyroid FNA revealed a metastatic RCC that led to the discovery of a clinically occult RCC. All 5 patients died of metastatic disease 27 to 40 months after surgical resection of their SMCTs.

  7. Spatially correlated heterogeneous aspirations to enhance network reciprocity

    Science.gov (United States)

    Tanimoto, Jun; Nakata, Makoto; Hagishima, Aya; Ikegaya, Naoki

    2012-02-01

    Perc & Wang demonstrated that aspiring to be the fittest under conditions of pairwise strategy updating enhances network reciprocity in structured populations playing 2×2 Prisoner's Dilemma games (Z. Wang, M. Perc, Aspiring to the fittest and promoted of cooperation in the Prisoner's Dilemma game, Physical Review E 82 (2010) 021115; M. Perc, Z. Wang, Heterogeneous aspiration promotes cooperation in the Prisoner's Dilemma game, PLOS one 5 (12) (2010) e15117). Through numerical simulations, this paper shows that network reciprocity is even greater if heterogeneous aspirations are imposed. We also suggest why heterogeneous aspiration fosters network reciprocity. It distributes strategy updating speed among agents in a manner that fortifies the initially allocated cooperators' clusters against invasion. This finding prompted us to further enhance the usual heterogeneous aspiration cases for heterogeneous network topologies. We find that a negative correlation between degree and aspiration level does extend cooperation among heterogeneously structured agents.

  8. Ultrasonic dissection versus conventional electrocautery during gastrectomy for gastric cancer: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Sun, Z C; Xu, W G; Xiao, X M; Yu, W H; Xu, D M; Xu, H M; Gao, H L; Wang, R X

    2015-04-01

    Use of ultrasonic surgical instrument is gaining popularity for dissection and coagulation in open surgery. However, there is still no consensus on the efficacy and safety of its use compared with conventional surgical technique in open gastrectomy for gastric cancer. The aim of this meta-analysis was to evaluate the role and surgical outcomes of ultrasonic dissection (UD) compared with conventional electrocautery (EC). A systematic literature search was performed to identify all studies comparing UD and EC in gastric cancer surgery. Intraoperative and postoperative outcomes were compared using weighted mean differences (WMDs) and odds ratios (ORs). Five studies were included in this meta-analysis, comprising 489 patients. Meta-analysis results showed that compared with EC, UD was associated with significantly shorter operation time (P = 0.03), less intraoperative blood loss (P = 0.002), lower morbidity (P = 0.02), and reduced postoperative hospital stay (P = 0.03). However, there was no significant difference between the two surgical techniques with regards to postoperative abdominal drainage (P = 0.17), and total cost in hospital (P = 0.59). Compared to EC, the use of UD during open gastrectomy can provide several improved outcomes for operation time, intraoperative blood loss, overall morbidity, and postoperative hospital stay. It appears that UD can be used instead of conventional EC in open gastric cancer surgery, although more larger trials with long follow-up should be performed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Electrocautery versus Ultracision versus LigaSure in Surgical Management of Hyperhidrosis.

    Science.gov (United States)

    Divisi, Duilio; Di Leonardo, Gabriella; De Vico, Andrea; Crisci, Roberto

    2015-12-01

    The aim of the study was to evaluate the sympathectomy procedures for primary hyperhidrosis in terms of complications and effectiveness. From January 2010 to September 2012 we performed 130 sympathectomies in 65 patients, 27 males (42%) and 38 females (58%). Electrocoagulation was used in 20 procedures (15%), ultrasonic scalpel in 54 (42%), and radiofrequency dissector in 56 (43%). Seven patients (11%) underwent bilateral sympathectomy in the same surgical session, while in 58 (89%) the right surgical approach was delayed 30 days from the first procedure. We noticed 12 complications (9%): (a) chest pain in 6 patients (4 with electrocoagulation, 1 with ultrasonic scalpel, and 1 with radiofrequency dissector), which disappeared in 20 ± 1 day; (b) paresthesias in 3 electrocoagulation patients, was solved in 23 ± 5 days; (c) bradycardia in 1 ultrasonic patient, normalized in 4th postoperative hour; (d) unilateral relapse in 2 electrocoagulation patients after the second side approach, positively treated in 1 patient by resurgery in video-assisted thoracoscopy (VAT). The quality-adjusted life year and the quality of life evaluation revealed a statistically significant improvement (p = 0.02) in excessive sweating and general satisfaction after surgery, with Ultracision and LigaSure showing better findings than electrocoagulation. The latest generation devices offered greater efficacy in the treatment of hyperhidrosis, minimizing complications and facilitating the resumption of normal work and social activity of patients. Georg Thieme Verlag KG Stuttgart · New York.

  10. The social contagion of aspirations

    DEFF Research Database (Denmark)

    Folmann, Birgitte

    2017-01-01

    among young men in Northern Uganda. The potential social contagion of aspirations is unfolded to provide a deeper understanding of social processes not only as dynamics between people but also as processes between people and their surroundings in a society which is subject to rapid change...... succeed, making some progress along this path seems important and fuels their ongoing aspiration for the good life. Having a ‘life style’ means being able to choose and consume, and getting a ‘life style’ reflects an aspiration for social mobility. Taking the emic approach helps to explain how social...... contagion occurs and how health-related practices are formed....

  11. Surgical management of an abdominal abscess in a Malayan tapir.

    Science.gov (United States)

    Lambeth, R R; Dart, A J; Vogelnest, L; Dart, C M; Hodgson, D R

    1998-10-01

    A captive Malayan tapir was observed to have inappetence, weight loss, signs of depression, mild dehydration and diarrhoea. Haematological and serum biochemical tests showed anaemia, hypoproteinaemia, hyperfibrinogenaemia and neutrophilia with a left shift. Ultrasonic examination of the abdomen under anaesthesia revealed a well-encapsulated abscess. The abscess was marsupialised to the ventral body wall. Culture of the pus produced a mixed bacterial growth. Antimicrobial therapy was based on bacterial sensitivity results. Follow-up ultrasonic examinations showed resolution of the abscess. Ninety-one days after surgery the tapir began regurgitating food and water. An abscess originating from the stomach and occluding the lumen of the duodenum was identified at surgery. The abscess ruptured during surgical manipulations and the tapir was euthanased.

  12. Thrombus aspiration catheter is a Dottering balloon

    Directory of Open Access Journals (Sweden)

    D. Sheshagiri Rao

    2016-07-01

    Full Text Available Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate?

  13. GEAR UP Aspirations Project Evaluation

    Science.gov (United States)

    Trimble, Brad A.

    2013-01-01

    The purpose of this study was to conduct a formative evaluation of the first two years of the Gaining Early Awareness and Readiness for Undergraduate Programs (GEAR UP) Aspirations Project (Aspirations) using a Context, Input, Process, and Product (CIPP) model so as to gain an in-depth understanding of the project during the middle school…

  14. Artificial Intelligence Assists Ultrasonic Inspection

    Science.gov (United States)

    Schaefer, Lloyd A.; Willenberg, James D.

    1992-01-01

    Subtle indications of flaws extracted from ultrasonic waveforms. Ultrasonic-inspection system uses artificial intelligence to help in identification of hidden flaws in electron-beam-welded castings. System involves application of flaw-classification logic to analysis of ultrasonic waveforms.

  15. In-vitro analysis of forces in conventional and ultrasonically assisted drilling of bone.

    Science.gov (United States)

    Alam, K; Hassan, Edris; Imran, Syed Husain; Khan, Mushtaq

    2016-05-12

    Drilling of bone is widely performed in orthopaedics for repair and reconstruction of bone. Current paper is focused on the efforts to minimize force generation during the drilling process. Ultrasonically Assisted Drilling (UAD) is a possible option to replace Conventional Drilling (CD) in bone surgical procedures. The purpose of this study was to investigate and analyze the effect of drilling parameters and ultrasonic parameters on the level of drilling thrust force in the presence of water irrigation. Drilling tests were performed on young bovine femoral bone using different parameters such as spindle speeds, feed rates, coolant flow rates, frequency and amplitudes of vibrations. The drilling force was significantly dropped with increase in drill rotation speed in both types of drilling. Increase in feed rate was more influential in raising the drilling force in CD compared to UAD. The force was significantly dropped when ultrasonic vibrations up to 10 kHz were imposed on the drill. The drill force was found to be unaffected by the range of amplitudes and the amount of water supplied to the drilling region in UAD. Low frequency vibrations with irrigation can be successfully used for safe and efficient drilling in bone.

  16. Perineal nodular indurations ("accessory testicles") in cyclists. Fine needle aspiration cytologic and pathologic findings in two cases.

    Science.gov (United States)

    Vuong, P N; Camuzard, P; Schoonaert, M F

    1988-01-01

    The cytologic and histologic findings from two cases of perineal nodular indurations observed in two cyclists are reported. These lesions, also referred to as "accessory testicles" or "third testicle" or "ischial hygromas" of cyclists, consist of a localized aseptic area of necrosis with pseudocyst formation involving connective tissue in the superficial fascia of the perineum. These histologic findings, which were seen in the subsequent surgical specimens in these two cases, were reflected in the fine needle aspiration findings. The aspirates contained few cellular elements, mainly a few vacuolated histiocytes, against a background of fibrinous material. These indurations, which develop as a result of repeated, chronic microtrauma to the perineum impressed by the vibration of the saddle of the bicycle, constitute an authentic handicap for the professional cyclist and are a contraindication to cycling for amateur cyclists.

  17. Ultrasonic grinding method

    International Nuclear Information System (INIS)

    Miyahara, Shuji.

    1990-01-01

    An ultrasonic generator and a liquid supply nozzle are opposed to an object to be ground and a pump is started in this state to supply an organic solvent. Matters to be decontaminated which adheres to the surface of the object to be ground and are difficult to be removed by a mere mechanical removing method can be eliminated previously by the surface active effect of the organic solvent such as ethanol prior to the oscillation of the ultrasonic generator. Subsequently, when the ultrasonic generator is oscillated, scales in the floated state can be removed simply. Further, since the organic solvent can penetrate to provide the surface active effect even in such a narrow portion that the top end of the ultrasonic generator is difficult to the intruded at the surface of the object to be ground, the decontaminating treatment can be applied also to such a narrow portion. (T.M.)

  18. ULTRASONIC ASSEMBLY [REVIEW

    Directory of Open Access Journals (Sweden)

    PORAV Viorica

    2015-05-01

    Full Text Available The paper exposes the possibility of machine producesers to optimize the costs of clothes assembling. Ultrasonic systems being frequently utilized have many advantages on semi products of synthetic textile and technical textile. First of all, sewing – cutting process can be accomplished under high speeds and rate of losses can be minimized. Cutting seal applications are frequently used for underwear and sportswear. Slicing and unit cutting machines, as well as portable sealing machines are available for labeling sector. Products such as bag, pocket and cover can be sewed in a seamless manner for promotion purposes. All objects in terms of accessories are obtained in same standard. Our quilting machines are preferred in worldwide due to its threadless, high quality sealing. An alternative to the classic sewing assembly, with thread and needles is ultrasonic seaming. In ultrasonic welding, there are no connective bolts, nails, soldering materials, or adhesives necessary to bind the materials together. Ultrasonic is defined as acoustic frequencies above the range audible to the human ear. Ultrasonic frequencies are administered to the fabric from the sonotrode of bonding machine. The high frequency and powerful energy produced, when is release in one special environment, the ultrasound heating this environment. The ability to ultrasonic weld textiles and films depend on their thermoplastic contents and the desired end results. The paper defines the weld ability of more common textiles and films. The welding refers to all types of bonding and sealing, as in point bonding of fabric, or continuous sealing of film.

  19. Thrombus aspiration catheter is a Dottering balloon.

    Science.gov (United States)

    Sheshagiri Rao, D; Barik, Ramachandra; Prasad, Akula Siva

    2016-01-01

    Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD) with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate? Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  20. Pediatric Eating Assessment Tool-10 as an indicator to predict aspiration in children with esophageal atresia.

    Science.gov (United States)

    Soyer, Tutku; Yalcin, Sule; Arslan, Selen Serel; Demir, Numan; Tanyel, Feridun Cahit

    2017-10-01

    Airway aspiration is a common problem in children with esophageal atresia (EA). Pediatric Eating Assessment Tool-10 (pEAT-10) is a self-administered questionnaire to evaluate dysphagia symptoms in children. A prospective study was performed to evaluate the validity of pEAT-10 to predict aspiration in children with EA. Patients with EA were evaluated for age, sex, type of atresia, presence of associated anomalies, type of esophageal repair, time of definitive treatment, and the beginning of oral feeding. Penetration-aspiration score (PAS) was evaluated with videofluoroscopy (VFS) and parents were surveyed for pEAT-10, dysphagia score (DS) and functional oral intake scale (FOIS). PAS scores greater than 7 were considered as risk of aspiration. EAT-10 values greater than 3 were assessed as abnormal. Higher DS scores shows dysphagia whereas higher FOIS shows better feeding abilities. Forty patients were included. Children with PAS greater than 7 were assessed as PAS+ group, and scores less than 7 were constituted as PAS- group. Demographic features and results of surgical treatments showed no difference between groups (p>0.05). The median values of PAS, pEAT-10 and DS scores were significantly higher in PAS+ group when compared to PAS- group (p<0.05). The sensitivity and specificity of pEAT-10 to predict aspiration were 88% and 77%, and the positive and negative predictive values were 22% and 11%, respectively. Type-C cases had better pEAT-10 and FOIS scores with respect to type-A cases, and both scores were statistically more reliable in primary repair than delayed repair (p<0.05). Among the postoperative complications, only leakage had impact on DS, pEAT-10, PAS and FOIS scores (p<0.05). The pEAT-10 is a valid, simple and reliable tool to predict aspiration in children. Patients with higher pEAT-10 scores should undergo detailed evaluation of deglutitive functions and assessment of risks of aspiration to improve safer feeding strategies. Level II (Development of

  1. Non-surgical and non-chemical attempts to treat echinococcosis: do they work?

    Directory of Open Access Journals (Sweden)

    Tamarozzi Francesca

    2014-01-01

    Full Text Available Cystic echinococcosis (CE and alveolar echinococcosis (AE are chronic, complex and neglected diseases. Their treatment depends on a number of factors related to the lesion, setting and patient. We performed a literature review of curative or palliative non-surgical, non-chemical interventions in CE and AE. In CE, some of these techniques, like radiofrequency thermal ablation (RFA, were shelved after initial attempts, while others, such as High-Intensity Focused Ultrasound, appear promising but are still in a pre-clinical phase. In AE, RFA has never been tested, however, radiotherapy or heavy-ion therapies have been attempted in experimental models. Still, application to humans is questionable. In CE, although prospective clinical studies are still lacking, therapeutic, non-surgical drainage techniques, such as PAIR (puncture, aspiration, injection, re-aspiration and its derivatives, are now considered a useful option in selected cases. Finally, palliative, non-surgical drainage techniques such as US- or CT-guided percutaneous biliary drainage, centro-parasitic abscesses drainage, or vascular stenting were performed successfully. Recently, endoscopic retrograde cholangiopancreatography (ERCP-associated techniques have become increasingly used to manage biliary fistulas in CE and biliary obstructions in AE. Development of pre-clinical animal models would allow testing for AE techniques developed for other indications, e.g. cancer. Prospective trials are required to determine the best use of PAIR, and associated procedures, and the indications and techniques of palliative drainage.

  2. Pre-hospital aspiration is associated with increased pulmonary complications.

    Science.gov (United States)

    Fawcett, Vanessa J; Warner, Keir J; Cuschieri, Joseph; Copass, Michael; Grabinsky, Andreas; Kwok, Heemun; Rea, Thomas; Evans, Heather L

    2015-04-01

    Rates of ventilator-associated pneumonia (VAP) are highest among patients intubated on an emergency basis following trauma. We reported previously a retrospective analysis demonstrating an association between subjective aspiration and VAP after pre-hospital intubation. We hypothesize that by directing paramedics to note features of aspiration at intubation, we will confirm prospectively the association between pre-hospital aspiration and subsequent pneumonia in trauma patients. Paramedics collected data regarding aspiration at the time of intubation. All intubated patients admitted to a level 1 trauma center intensive care unit (ICU) were included. Data comprised a clinical impression of pre-hospital aspiration, as well as the presence and timing of blood and emesis in the airway. Injury severity, co-morbidities, and outcomes were collected from the trauma registry. Healthcare-associated pneumonia (HAP) was identified by medical record review of both bronchoalveolar lavage culture results and discharge diagnosis. Descriptive statistics and univariate analysis of outcomes by aspiration status, as well as covariable adjustment using propensity scores, were performed. Of the 228 patients, 89 (39%) were determined by paramedics to have aspirated. The majority of those who aspirated (84 [94%]) did so prior to intubation. Patients who aspirated had higher Injury Severity Scores than those who did not aspirate (25.0 ± 1.7 vs. 21.9 ± 1.5 points; p=0.04) and lower preintubation Glasgow Coma Scale scores (8.2 ± 0.50 vs. 9.6 ± 0.40; p=0.02). Of the 89 patients who aspirated around the time of intubation, 14 (16%) developed HAP vs. five (3.6%) of those who did not aspirate (paspiration (deaths: 21 [23.6%] vs. 23 [16.6%]; p=0.19; ICU LOS: 5.3 ± 0.9 vs. 4.1 ± 0.5 days; p=0.13; duration of mechanical ventilation: 5.3 ± 1.2 vs. 3.2 ± 0.5 days; p=0.10). Aspiration prior to intubation was reported commonly by paramedics and was associated with a higher risk of HAP.

  3. A low-hemolysis blood aspirator conserves blood during surgery.

    Science.gov (United States)

    Clague, C T; Blackshear, P L

    1995-01-01

    Blood damage caused by traditional vacuum-operated suction tubes, particularly when air is aspirated along with the blood, usually exceeds damage from all other components. In addition to platelet injury, there is a high degree of hemolysis, which leads to high plasma hemoglobin levels and reduces the number of red blood cells available for reinfusion during cases of blood conservation, such as autologous transfusion and cardiac bypass. This work was undertaken to minimize hemolysis, and the accompanying platelet destruction, during aspiration, with the design of a jet-driven aspirator that separates and removes air from blood immediately within the suction tip. The jet-driven aspirator can suction blood at a range of rates from 100 to at least 700 ml/min, separates and removes 80-100% of aspirated air, operates at any orientation, and generates subatmospheric pressures on the order of only 1 inch H2O. In-vitro hemolysis testing showed a significant reduction in average plasma hemoglobin release, from 19.4 mg/dl to 1.8 mg/dl, when air was removed during blood aspiration. In comparative testing with a conventional vacuum suction tube, the jet-driven aspirator showed significantly less hemolysis than the conventional aspirator at comparable rates of air and blood aspiration.

  4. Aspiration Deaths Among Adults in Istanbul

    Directory of Open Access Journals (Sweden)

    Haşim Asil

    2014-06-01

    Full Text Available Massive aspiration of food is rare, but most common in people under the influence of alcohol or a drug and comatose patients who have impaired functioning of the central nervous system. The finding of small amounts of food material in the airway at autopsy does not indicate the true vital aspiration because of agonal or even early post-mortem overspills. Occlusion of the small airways, mainly the membranous and respiratory bronchioles, partial or total filling of bronchiolar lumen and the alveolar spaces with food or gastric content were typical morphologic findings. In our 10 year retrospective study we presented the data of 21 male and 4 female cases with a final diagnosis of fatal aspiration in age from 23 to 78 years (45.43±14.61 from the records of Morgue Specialization Department of the Council of Forensic Medicine. 13 cases found death at the scene without an eyewitness. All deaths were accidental in manner except one homicide. Toxicological analysis revealed blood alcohol concentration levels between 161 and 339 mg/dL in 7 cases. Morphine metabolites, benzodiazepine and barbituric acid derivatives, toluene and acetone were detected in 5 subjects. Aspirated materials were food in 14 cases, chewing gum in 3 cases, gastric content in 7 cases and a fabric gag in one case. The history, other evidence of external vomit on the clothing or immediate surroundings and toxicological analysis are by no means as significant as autopsy findings especially in cases of aspiration. Key words : adult; aspiration; death; autopsy

  5. Shareholders’ expectations, aspiration levels, and mergers

    NARCIS (Netherlands)

    Diecidue, E.; van de Ven, J.; Weitzel, U.

    This paper offers a new explanation of value-reducing mergers and stock market driven takeovers by introducing recent research on aspiration levels and individual decision making under risk. If market valuation constitutes an aspiration level for managers, we show that managers may be tempted to

  6. Decrease in use of manual vacuum aspiration in postabortion care in Malawi: a cross-sectional study from three public hospitals, 2008-2012.

    Directory of Open Access Journals (Sweden)

    Maria L Odland

    Full Text Available OBJECTIVES: To investigate the use of manual vacuum aspiration in postabortion care in Malawi between 2008-2012. METHODS: A retrospective cross-sectional study was done at the referral hospital Queen Elisabeth Central Hospital, and the two district hospitals of Chiradzulu and Mangochi. The data were collected simultaneously at the three sites from Feb-March 2013. All records available for women admitted to the gynaecological ward from 2008-2012 were reviewed. Women who had undergone surgical uterine evacuation after incomplete abortion were included and the use of manual vacuum aspiration versus sharp curettage was analysed. RESULTS: Altogether, 5121 women were included. One third (34.2% of first trimester abortions were treated with manual vacuum aspiration, while all others were treated with sharp curettage. There were significant differences between the hospitals and between years. Overall there was an increase in the use of manual vacuum aspiration from 2008 (19.7% to 2009 (31.0%, with a rapid decline after 2010 (28.5% ending at only 4.9% in 2012. Conversely there was an increase in use of sharp curettage in all hospitals from 2010 to 2012. CONCLUSION: Use of manual vacuum aspiration as part of the postabortion care in Malawi is rather low, and decreased from 2010 to 2012, while the use of sharp curettage became more frequent. This is in contrast with current international guidelines.

  7. Habits, aspirations and endogenous fertility

    OpenAIRE

    Luciano Fanti

    2012-01-01

    Motivated by the increasing literature on endogenous preferences as well as on endogenous fertility, this paper investigates the implications of the interaction of the endogenous determination of the number of children with habit and aspiration formation in an OLG model. In contrast with the previous literature, we show that greater aspirations may lead to higher savings, and more interestingly, always increase the neoclassical economic growth.

  8. Remote consulting based on ultrasonic digital immages and dynamic ultrasonic sequences

    Science.gov (United States)

    Margan, Anamarija; Rustemović, Nadan

    2006-03-01

    Telematic ultrasonic diagnostics is a relatively new tool in providing health care to patients in remote, islolated communities. Our project facility, "The Virtual Polyclinic - A Specialists' Consulting Network for the Islands", is located on the island of Cres in the Adriatic Sea in Croatia and has been extending telemedical services to the archipelago population since 2000. Telemedicine applications include consulting services by specialists at the University Clinical Hospital Center Rebro in Zagreb and at "Magdalena", a leading cardiology clinic in Croatia. After several years of experience with static high resolution ultrasonic digital immages for referral consulting diagnostics purposes, we now also use dynamic ultrasonic sequences in a project with the Department of Emmergency Gastroenterology at Rebro in Zagreb. The aim of the ongoing project is to compare the advantages and shortcomings in transmitting static ultrasonic digital immages and live sequences of ultrasonic examination in telematic diagnostics. Ultrasonic examination is a dynamic process in which the diagnostic accuracy is highly dependent on the dynamic moment of an ultrasound probe and signal. Our first results indicate that in diffuse parenchymal organ pathology the progression and the follow up of a disease is better presented to a remote consulting specialist by dynamic ultrasound sequences. However, the changes that involve only one part of a parenchymal organ can be suitably presented by static ultrasonic digital images alone. Furthermore, we need less time for digital imaging and such tele-consultations overall are more economical. Our previous telemedicine research and practice proved that we can greatly improve the level of medical care in remote healthcare facilities and cut healthcare costs considerably. The experience in the ongoing project points to a conclusion that we can further optimize remote diagnostics benefits by a right choice of telematic application thus reaching a

  9. Ultrasonic flow meter

    NARCIS (Netherlands)

    Lötters, Joost Conrad; Snijders, G.J.; Volker, A.W.F.

    2014-01-01

    The invention relates to an ultrasonic flow meter comprising a flow tube for the fluid whose flow rate is to be determined. The flow meter comprises a transmitting element for emitting ultrasonic waves, which is provided on the outer jacket of the flow tube. A receiving element, which is provided on

  10. Aspirations, Expectations and Delinquency: The Moderating Effect of Impulse Control.

    Science.gov (United States)

    Mahler, Alissa; Simmons, Cortney; Frick, Paul J; Steinberg, Laurence; Cauffman, Elizabeth

    2017-07-01

    Although prior research finds a robust link between delinquent behavior and expectations, or an adolescent's perceived likelihood of obtaining one's future goals, fewer studies have evaluated aspirations, or the perceived importance of achieving one's goals. In addition, few studies consider how individual traits such as impulsivity affect the degree to which expectations and aspirations motivate or deter delinquent behavior. We contribute to this body of research by evaluating the independent effects of expectations and aspirations, and the aspiration-expectation gap (i.e., strain) on delinquent behavior during the year following an adolescent's first arrest using a large (N = 1117), racially/ethnically diverse sample of male adolescents (46.55% Latino, 35.81% Black, 14.95% White, and 2.69% Other race). In addition, we considered how impulse control interacts with expectations, aspirations, and strain to motivate behavior. Our results indicated that both aspirations, expectations and strain uniquely influence criminal behavior. Importantly, aspirations interacted with impulse control, such that aspirations affected delinquency only among youth with higher impulse control. Our findings suggest that aspirations may only influence behavior if youth also have the psychosocial capabilities to consider their future aspirations when behaving in the present.

  11. Ultrasonic Low-Friction Containment Plate for Thermal and Ultrasonic Stir Weld Processes

    Science.gov (United States)

    Graff, Karl; Short, Matt

    2013-01-01

    The thermal stir welding (TSW) process is finding applications in fabrication of space vehicles. In this process, workpieces to be joined by TSW are drawn, by heavy forces, between "containment plates," past the TSW tool that then causes joining of the separate plates. It is believed that the TSW process would be significantly improved by reducing the draw force, and that this could be achieved by reducing the friction forces between the workpieces and containment plates. Based on use of high-power ultrasonics in metal forming processes, where friction reduction in drawing dies has been achieved, it is believed that ultrasonic vibrations of the containment plates could achieve similar friction reduction in the TSW process. By applying ultrasonic vibrations to the containment plates in a longitudinal vibration mode, as well as by mounting and holding the containment plates in a specific manner such as to permit the plates to acoustically float, friction between the metal parts and the containment plates is greatly reduced, and so is the drawing force. The concept was to bring in the ultrasonics from the sides of the plates, permitting the ultrasonic hardware to be placed to the side, away from the equipment that contains the thermal stir tooling and that applies clamping forces to the plates. Tests demonstrated that one of the major objectives of applying ultrasonics to the thermal stir system, that of reducing draw force friction, should be achievable on a scaled-up system.

  12. Comparative study of conventional and ultrasonically-assisted bone drilling.

    Science.gov (United States)

    Alam, K; Ahmed, Naseer; Silberschmidt, V V

    2014-01-01

    Bone drilling is a well-known surgical procedure in orthopaedics and dentistry for fracture treatment and reconstruction. Advanced understanding of the mechanics of the drill-bone interaction is necessary to overcome challenges associated with the process and related postoperative complications. The aim of this study was to explore the benefits of a novel drilling technique, ultrasonically-assisted drilling (UAD), and its possible utilization in orthopaedic surgeries. The study was performed by conducting experiments to understand the basic mechanics of the drilling process using high speed filming of the drilling zone followed by measurements to quantify thrust force, surface roughness and cracking of the bone near the immediate vicinity of the hole with and without ultrasonic assistance. Compared to the spiral chips produced during conventional drilling (CD), UAD was found to break the chips in small pieces which facilitated their fast evacuation from the cutting region. In UAD, lower drilling force and better surface roughness was measured in drilling in the radial and longitudinal axis of the bone. UAD produced crack-free holes which will enhance postoperative performance of fixative devices anchoring the bone. UAD may be used as a possible substitute for CD in orthopaedic clinics.

  13. Risk Factors for Aspiration Pneumonia in Older Adults.

    Directory of Open Access Journals (Sweden)

    Toshie Manabe

    Full Text Available Aspiration pneumonia is a dominant form of community-acquired and healthcare-associated pneumonia, and a leading cause of death among ageing populations. However, the risk factors for developing aspiration pneumonia in older adults have not been fully evaluated. The purpose of the present study was to determine the risk factors for aspiration pneumonia among the elderly.We conducted an observational study using data from a nationwide survey of geriatric medical and nursing center in Japan. The study subjects included 9930 patients (median age: 86 years, women: 76% who were divided into two groups: those who had experienced an episode of aspiration pneumonia in the previous 3 months and those who had not. Data on demographics, clinical status, activities of daily living (ADL, and major illnesses were compared between subjects with and without aspiration pneumonia. Two hundred and fifty-nine subjects (2.6% of the total sample were in the aspiration pneumonia group. In the univariate analysis, older age was not found to be a risk factor for aspiration pneumonia, but the following were: sputum suctioning (odds ratio [OR] = 17.25, 95% confidence interval [CI]: 13.16-22.62, p < 0.001, daily oxygen therapy (OR = 8.29, 95% CI: 4.39-15.65, feeding support dependency (OR = 8.10, 95% CI: 6.27-10.48, p < 0.001, and urinary catheterization (OR = 4.08, 95% CI: 2.81-5.91, p < 0.001. In the multiple logistic regression analysis, the risk factors associated with aspiration pneumonia after propensity-adjustment (258 subjects each were sputum suctioning (OR = 3.276, 95% CI: 1.910-5.619, deterioration of swallowing function in the past 3 months (OR = 3.584, 95% CI: 1.948-6.952, dehydration (OR = 8.019, 95% CI: 2.720-23.643, and dementia (OR = 1.618, 95% CI: 1.031-2.539.The risk factors for aspiration pneumonia were sputum suctioning, deterioration of swallowing function, dehydration, and dementia. These results could help improve clinical management for preventing

  14. Computer automation of ultrasonic testing. [inspection of ultrasonic welding

    Science.gov (United States)

    Yee, B. G. W.; Kerlin, E. E.; Gardner, A. H.; Dunmyer, D.; Wells, T. G.; Robinson, A. R.; Kunselman, J. S.; Walker, T. C.

    1974-01-01

    Report describes a prototype computer-automated ultrasonic system developed for the inspection of weldments. This system can be operated in three modes: manual, automatic, and computer-controlled. In the computer-controlled mode, the system will automatically acquire, process, analyze, store, and display ultrasonic inspection data in real-time. Flaw size (in cross-section), location (depth), and type (porosity-like or crack-like) can be automatically discerned and displayed. The results and pertinent parameters are recorded.

  15. Ultrasonic inspection of austenitic welds

    International Nuclear Information System (INIS)

    Baikie, B.L.; Wagg, A.R.; Whittle, M.J.; Yapp, D.

    1976-01-01

    The ultrasonic examination of austenitic stainless steel weld metal has always been regarded as a difficult proposition because of the large and variable ultrasonic attenuations and back scattering obtained from apparently similar weld deposits. The work to be described shows how the existence of a fibre texture within each weld deposit (as a result of epitaxial growth through successive weld beads) produces a systematic variation in the ultrasonic attenuation coefficient and the velocity of sound, depending upon the angle between the ultrasonic beam and the fibre axis. Development work has shown that it is possible to adjust the welding parameters to ensure that the crystallographic texture within each weld is compatible with improved ultrasonic transmission. The application of the results to the inspection of a specific weld in type 316 weld metal is described

  16. Irradiation Testing of Ultrasonic Transducers

    International Nuclear Information System (INIS)

    Daw, J.; Rempe, J.; Palmer, J.; Tittmann, B.; Reinhardt, B.; Kohse, G.; Ramuhalli, P.; Montgomery, R.; Chien, H.T.; Villard, J.F.

    2013-06-01

    Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of numerous parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 10 21 n/cm 2 (E> 0.1 MeV). This test will be an instrumented lead test; and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. By characterizing magnetostrictive and piezoelectric transducer survivability during irradiation, test results will enable the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. (authors)

  17. Stereotactic aspiration versus craniotomy for primary intracerebral hemorrhage: a meta-analysis of randomized controlled trials.

    Directory of Open Access Journals (Sweden)

    Jia-Wei Wang

    Full Text Available BACKGROUND: A wealth of evidence based on the randomized controlled trials (RCTs has indicated that surgery may be a better choice in the management of primary intracerebral hemorrhage (ICH compared to conservative treatment. However, there is considerable controversy over selecting appropriate surgical procedures for ICH. Thus, this meta-analysis was performed to assess the effects of stereotactic aspiration compared to craniotomy in patients with ICH. METHODS: According to the study strategy, we searched PUBMED, EMBASE and Cochrane Central Register of Controlled Trials. Other sources such as the internet-based clinical trial registries, relevant journals and the lists of references were also searched. After literature searching, two investigators independently performed literature screening, assessment of quality of the included trials and data extraction. The outcome measures included death or dependence, total risk of complication, and the risk of rebleeding, gastrointestinal hemorrhage and systematic infection. RESULTS: Four RCTs with 2996 participants were included. The quality of the included trials was acceptable. Stereotactic aspiration significantly decreased the odds of death or dependence at the final follow-up (odds ratio (OR: 0.80, 95% confidence interval (CI: 0.69-0.93; P = 0.004 and the risk of intracerebral rebleeding (OR: 0.44, 95% CI: 0.26-0.74; P = 0.002 compared to craniotomy with no significant heterogeneity among the study results. CONCLUSIONS: The present meta-analysis provides evidence that the stereotactic aspiration may be associated with a reduction in the odds of being dead or dependent in primary ICH, which should be interpreted with caution. Further trials are needed to identify those patients most likely to benefit from the stereotactic aspiration.

  18. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  19. Employment, Academic and Extracurricular Contributors to College Aspirations

    Science.gov (United States)

    McGaha, Valerie; Fitzpatrick, Jacki

    2010-01-01

    Although there have been many studies on college entrance and aspirations, little attention has been paid to post-high school adults (who enter the workworld rather than college). it is possible that post-high school adults still have college aspirations, and it would be valuable to identify the factors that foster such aspirations. This study…

  20. An unusual case of foreign body aspiration mimicking cavitary tuberculosis in adolescent patient: Thread aspiration

    Directory of Open Access Journals (Sweden)

    Cakir Erkan

    2012-05-01

    Full Text Available Abstract Foreign body aspiration continues to be a serious problem in childhood and adolescent period with significant rate of morbidity and rarely mortality. Half of the foreign body aspiration cases have no history of aspiration. The main foreign bodies inhaled are food fragments and different kinds of metallic objects. A 12-year-old girl was referred to the pediatric pulmonology department for chronic cough and hemoptysis. She had persistent infiltration and cavitary lesion mimicking cavitary tuberculosis. There was no contact history with tuberculosis in her family and acid resistant bacillus was not found in the sputum examination. Flexible bronchoscopy was performed for persistent infiltration and hemoptysis and inflamed thread was found in right lower lobe bronchus. This is the first case of thread inhalation mimicking cavitary tuberculosis in an adolescent patient.

  1. Surgical treatment of a large congenital cavernous hemangioma on the thorax of a foal

    DEFF Research Database (Denmark)

    Jacobsen, Stine; Christophersen, Mogens Teken; Tnibar, Aziz

    2018-01-01

    A 3-day-old male foal was presented with a fluctuant 25 × 15 cm mass on the thorax. The mass had increased in size since birth. The mass did not respond to conservative treatment consisting of aspiration of serohaemorrhagic contents and compression bandages, and it was therefore surgically removed...... when the foal was approximately 2½ weeks. A histopathological diagnosis of cavernous haemangioma was made. Healing progressed without complications despite a large surgical wound left to heal by second intention. Recurrence was not observed during the 1.5-year follow-up period....

  2. Ultrasonic dip seal maintenance system

    International Nuclear Information System (INIS)

    Poindexter, A.M.; Ricks, H.E.

    1978-01-01

    Disclosed is a system for removing impurities from the surfaces of liquid dip seals and for wetting the metal surfaces of liquid dip seals in nuclear components. The system comprises an ultrasonic transducer that transmits ultrasonic vibrations along an ultrasonic probe to the metal and liquid surfaces of the dip seal thereby loosening and removing those impurities

  3. Ultrasonic energy vs monopolar electrosurgery in laparoscopic cholecystectomy: a comparison of tissue damage

    Directory of Open Access Journals (Sweden)

    Mehdi Asgari

    2016-04-01

    Full Text Available Background: Laparoscopic cholecystectomy is a minimally invasive procedure whereby the gallbladder is removed using laparoscopic techniques. Monopolar electerosurgical energy is the method of dissection of gallbladder from liver bed. Ultrasonic energy causes less thermal damage and suggests an alternative to monopolar elevterocautery. Leptin is a tissue factor and C-reactive protein (CRP is an acute phase protein that builds up in surgical damages. In laparoscopy, pneumoperitoneum and thermal damage cause this increase. In this study, after completion of surgery with both methods, plasma leptin and CPR were measured. Next, the complications and benefits of the two methods were compared. Methods: This single blind randomized clinical trial was conducted on 78 patients who were candidate for laparoscopic cholecystectomy in surgery clinic of Razi Teaching Hospital in Ahvaz Jundishapur University of Medical Sciences from March 2013 to March 2015. Patients were divided randomly into two groups of ultrasonic and electerocautery. Then, leptin’s level and CRP’s level were measured at completion of surgery, 30 minutes after completion, 6 and 24 hours after completion of surgery in the two groups. Results: This study shows that the average rate of leptin at completion of surgery, 30 minutes after completion, 6 and 24 hours after completion of surgery in ultrasonic group had less increase than electerocautery group and the difference was statistically significant (P= 0.0001. The average rate of CRP at completion of surgery, 30 minutes after completion, 6 and 24 hours after completion of surgery in ultrasonic group had less increase than electerocautery group and the difference was statistically significant (P= 0.0001. Conclusion: The level of leptin and CRP shows that surgery with ultrasonic method will provoke the immune system less than electerocautery method.

  4. Scintigraphic diagnosis of silent aspiration following double-sided lung transplantation

    International Nuclear Information System (INIS)

    Toenshoff, G.; Stock, U.; Bohuslavizki, K.H.; Brenner, W.; Costard-Jaeckle, A.; Cremer, J.; Clausen, M.

    1996-01-01

    We present a case of a 25 year old patient who underwent double-sided lung transplantation and suffered from recurrent pneumonia. Silent aspiration was suspected clinically. Aspiration was proved by scintigraphy enabling to discriminate between direct oro-pulmonal aspiration and aspiration after gastro-esophageal reflux. (orig.) [de

  5. Aspiration Curettage and its Outpatient Usage

    African Journals Online (AJOL)

    Aspiration Curettage and its Outpatient Usage. D. A. G. BARFORD, M, NOTELOVITZ. SUMMARY ... its use on a number of outpatients without anaesthesia is discussed. S. Afr. Med. l., 48, 22 (1974). In order to ... plastic aspiration chamber and suction is applied centrally at the base of the chamber, a cylindrical filter within the.

  6. Aspirating and Nonaspirating Swallow Sounds in Children: A Pilot Study.

    Science.gov (United States)

    Frakking, Thuy; Chang, Anne; O'Grady, Kerry; David, Michael; Weir, Kelly

    2016-12-01

    Cervical auscultation (CA) may be used to complement feeding/swallowing evaluations when assessing for aspiration. There are no published pediatric studies that compare the properties of sounds between aspirating and nonaspirating swallows. To establish acoustic and perceptual profiles of aspirating and nonaspirating swallow sounds and determine if a difference exists between these 2 swallowing types. Aspiration sound clips were obtained from recordings using CA simultaneously undertaken with videofluoroscopic swallow study. Aspiration was determined using the Penetration-Aspiration Scale. The presence of perceptual swallow/breath parameters was rated by 2 speech pathologists who were blinded to the type of swallow. Acoustic data between groups were compared using Mann Whitney U-tests, while perceptual differences were determined by a test of 2 proportions. Combinations of perceptual parameters of 50 swallows (27 aspiration, 23 no aspiration) from 47 children (57% male) were statistically analyzed using area under a receiver operating characteristic (aROC), sensitivity, specificity, and positive and negative predictive values to determine predictors of aspirating swallows. The combination of post-swallow presence of wet breathing and wheeze and absence of GRS and normal breathing was the best predictor of aspiration (aROC = 0.82, 95% CI, 0.70-0.94). There were no significant differences between these 2 swallow types for peak frequency, duration, and peak amplitude. Our pilot study has shown that certain characteristics of swallow obtained using CA may be useful in the prediction of aspiration. However, further research comparing the acoustic swallowing sound profiles of normal children to children with dysphagia (who are aspirating) on a larger scale is required. © The Author(s) 2016.

  7. Ultrasonic neuromodulation

    Science.gov (United States)

    Naor, Omer; Krupa, Steve; Shoham, Shy

    2016-06-01

    Ultrasonic waves can be non-invasively steered and focused into mm-scale regions across the human body and brain, and their application in generating controlled artificial modulation of neuronal activity could therefore potentially have profound implications for neural science and engineering. Ultrasonic neuro-modulation phenomena were experimentally observed and studied for nearly a century, with recent discoveries on direct neural excitation and suppression sparking a new wave of investigations in models ranging from rodents to humans. In this paper we review the physics, engineering and scientific aspects of ultrasonic fields, their control in both space and time, and their effect on neuronal activity, including a survey of both the field’s foundational history and of recent findings. We describe key constraints encountered in this field, as well as key engineering systems developed to surmount them. In closing, the state of the art is discussed, with an emphasis on emerging research and clinical directions.

  8. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  9. A randomized controlled trial of peeling and aspiration of Elschnig pearls and neodymium: yttrium-aluminium-garnet laser capsulotomy.

    Science.gov (United States)

    Bhargava, Rahul; Kumar, Prachi; Sharma, Shiv Kumar; Kaur, Avinash

    2015-01-01

    To compare surgical peeling and aspiration and neodymium yttrium garnet laser capsulotomy for pearl form of posterior capsule opacification (PCO). A prospective, randomized, double blind, study was done at Rotary Eye Hospital, Maranda, Palampur, India, Santosh Medical College Hospital, Ghaziabad, India and Laser Eye Clinic, Noida India. Consecutive patients with pearl form of PCO following surgery, phacoemulsification, manual small incision cataract surgery and conventional extracapsular cataract extraction (ECCE) for age related cataract, were randomized to have peeling and aspiration or neodymium yttrium garnet laser capsulotomy. Corrected distance visual acuity (CDVA), intra-operative and post-operative complications were compared. A total of 634 patients participated in the study, and 314 (49.5%) patients were randomized to surgical peeling and aspiration group and 320 (50.5%) to the Nd:YAG laser group. The mean pre-procedural logMAR CDVA in peeling and neodymium: yttrium-aluminium-garnet (Nd:YAG) laser group was 0.80±0.25 and 0.86±0.22, respectively. The mean final CDVA in peeling group (0.22±0.23) was comparable to Nd:YAG group (0.24±0.28; t test, P=0.240). There was a significant improvement in vision after both the procedures (Ppeeling group (262/83.4%) had a CDVA of 0.5 (20/63) or better at 9mo (Ppeeling group (25/7.7% vs 15/4.7%, respectively). On application of ANCOVA, there was less than 0.001% risk that PCO thickness and total laser energy had no effect on rate of complications in Nd:YAG laser group and less than 0.001 % risk that PCO thickness had no effect on complications in peeling group respectively. Sum of square analysis suggests that in the Nd:YAG laser group, thick PCO had a stronger impact on complications (Fischer test probability, Prpeeling group, thick PCO and preoperative vision had a stronger effect on complications than thin PCO, respectively (Fischer test probability, Prpeeling group. Retinal detachment was more common in patients

  10. FOREIGN BODY ASPIRATION: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Nafia Ozlem Kazanci

    2013-03-01

    Full Text Available Foreign body aspiration (FBA is common under 3 years of age. FBA can cause sudden respiratory failure. Furthermore, it leads to many respiratory system complications. Therefore, FBA is an important cause of mortality and morbidity for this age group. FBA cases are usually followed by diagnoses like pneumonia, bronchitis or bronchial asthma in the late period that history, clinical and laboratory findings suggesting foreign body aspiration can not be detected. We reported a 2-year-old male patient with pneumonia, who were administered various treatments. In thorax CT of this case, an image compatible with foreign body was seen in the right middle lobe-upper lobe separation area. Granulation tissue was detected in the entrance of the right main bronchus by rigid bronchoscopy and marked improvement occured in lung aeration after bronchoscopy. This case was reported to emphasize the importance of early diagnosis of foreign body aspiration because of high mortality and morbidity and the necessity of considering the foreign body aspiration in children with recurrent pulmonary infections. [J Contemp Med 2013; 3(1.000: 58-61

  11. Ultrasonic flowmeters

    International Nuclear Information System (INIS)

    Wittekind, W.D.

    1979-01-01

    A prototype ultrasonic flowmeter was assembled and tested. The theoretical basis of this prototype ultrasonic flowmeter is reviewed; the equipment requirements for a portable unit are discussed; the individual electronic modules contained in the prototype are described; the operating procedures and configuration are explained; and the data from preliminary calibrations are presented. The calibration data confirm that the prototype operates according to theoretical predictions and can indeed provide nonintrusive flow measurements to predicted accuracies for pipes larger than two inches, under single phase stable flow conditions

  12. Pulsed ultrasonic stir welding system

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2013-01-01

    An ultrasonic stir welding system includes a welding head assembly having a plate and a rod passing through the plate. The rod is rotatable about a longitudinal axis thereof. During a welding operation, ultrasonic pulses are applied to the rod as it rotates about its longitudinal axis. The ultrasonic pulses are applied in such a way that they propagate parallel to the longitudinal axis of the rod.

  13. Does Fine Needle Aspiration Microbiology Offer Any Benefit Over Wound Swab in Detecting the Causative Organisms in Surgical Site Infections?

    Science.gov (United States)

    Sudharsanan, Sundaramurthi; Gs, Sreenath; Sureshkumar, Sathasivam; Vijayakumar, Chellappa; Sujatha, Sistla; Kate, Vikram

    2017-09-01

    The objective of this study is to determine the role of ne needle aspiration microbiology (FNAM) in detecting the causative organisms of postoperative surgical site infections (SSIs) in comparison with the standard technique of surface swabbing. Ma- terials and Methods. In this study, 150 patients with SSIs following elective and emergency operations were included. In all patients, FNAM was performed along with conventional surface swabbing to identify the causative microorganism. Sensitivity of surface swab and FNAM was calculated as the number of samples collected from the diagnosed case of SSI. A total of 115 positive cultures were obtained from the 150 patients with SSIs; surface swab was positive in 110 cases and FNAM was positive in 94 cases. The mean number of organisms isolated by surface swab, and FNAM was 0.95 and 0.8, respectively. The sensitivity of surface swab was 94.3% in elective cases and 96.25% in emergency cases. The sensitivity of FNAM was 82.8% in elective cases and 82.5% in emergency cases. The sensitivity and negative predictive value of FNAM and surface swab did not signi cantly differ in clean elective cases. The overall sensitivity of surface swab and FNAM was 95.65% and 81.7%, respectively. Comparing the antibiotic suscep- tibility pattern, no difference was observed when the same organ- ism was isolated by both methods, indicating that FNAM does not offer bene t over the conventional wound surface swab in detecting microorganisms in SSI in both elective and emergency surgeries. In certain cases with unexplained wound infections, FNAM can be used as an investigation to identify speci c pathogens not detected by conventional surface swab.

  14. Incisional endometriosis: diagnosed by fine needle aspiration cytology.

    Science.gov (United States)

    Veda, P; Srinivasaiah, M

    2010-07-01

    Incisional endometriosis (IE) is a rare entity reported in 0.03-1.08% of women following obstetric or gynecologic surgeries. Most cases reported in literature have appeared after cesarean sections and were often clinically mistaken for hernia, abscess, suture granuloma or lipoma. We hereby report a case of IE following a second trimester hysterotomy, which was diagnosed by fine needle aspiration cytology (FNAC). Our patient was 26 years old, presenting with a mass over anterior abdominal wall, associated with incapacitating pain during each menstrual cycle. FNAC showed epithelial cells, stromal cells and hemosiderin laden macrophages. Based on the typical history, clinical and cytological features, the diagnosis of IE was established. Wide surgical excision was done and the resulting rectus sheath defect was repaired. Patient was followed for 6 months during which time she was symptom free. This article also reviews the spectrum of cytological features and the rare possibility of malignant transformation that can occur in IE.

  15. Videofluoroscopic Predictors of Penetration-Aspiration in Parkinson's Disease Patients.

    Science.gov (United States)

    Argolo, Natalie; Sampaio, Marília; Pinho, Patrícia; Melo, Ailton; Nóbrega, Ana Caline

    2015-12-01

    Parkinson's disease (PD) patients show a high prevalence of swallowing disorders and tracheal aspiration of food. The videofluoroscopic study of swallowing (VFSS) allows clinicians to visualize the visuoperceptual and temporal parameters associated with swallowing disorders in an attempt to predict aspiration risk. However, this subject remains understudied in PD populations. Our aim was to identify the predictors of penetration-aspiration in PD patients using the VFSS. Consecutive patients were evaluated using VFSS with different consistencies and volumes of food. A speech-language pathologist measured the type of intra-oral bolus organization, loss of bolus control, bolus location at the initiation of the pharyngeal swallow, the presence of multiple swallows, piecemeal deglutition, bolus residue in the pharyngeal recesses and temporal measures. Scores ≥3 on the penetration-aspiration scale (PAS) indicated the occurrence of penetration-aspiration. Using logistic marginal regression, we found that residue in the vallecula, residue in the upper esophageal sphincter and piecemeal deglutition were associated with penetration-aspiration (odds ratio (OR) = 4.09, 2.87 and 3.83; P = 0.0040, 0.0071 and 0.0009, respectively). Penetration/aspiration occurred only with fluids (both of thin and thick consistency), and no significant differences were observed between fluid types or food volumes. The mechanisms underlying dysphagia and penetration/aspiration in PD patients and indications for further studies are discussed.

  16. Aspiration pneumonia. Pathophysiological aspects, prevention and management. A review.

    Science.gov (United States)

    Petroianni, A; Ceccarelli, D; Conti, V; Terzano, C

    2006-12-01

    Aspiration pneumonias occur more frequently than reported and, in many cases, the disease is not recognised. In hospitalised and institutionalised patients with predisposing diseases prompt diagnosis of this complication and correct preventive measures can drastically reduce the worsening of clinical conditions and the deaths due to aspiration pneumonia. Normal airway structure, effective defence mechanisms, and preventive measures are decisive in reducing aspiration episodes. An increased aspiration risk for food, fluids, medications, or secretions may lead to the development of pneumonia. Pneumonia is the most common respiratory complication in all stroke deaths and in mechanical ventilation patients. In addition, the increased incidence of aspiration pneumonia with aging may be a consequence of impairment of swallowing and the cough reflex. Dysphagia, compromised consciousness, invasive procedures, anaesthesia, insufficient oral care, sleep disorders, and vomiting are all risk factors. Aspiration pneumonia includes different characteristic syndromes based on the amount (massive, acute, chronic) and physical character of the aspirated material (acid, infected, lipoid), needing a different therapeutic approach. Chronic patients education and correct health care practices are the keys for preventing the events of aspiration. In patients at risk a clinical and instrumental assessment of dysphagia should be evaluated. Management includes the removal of etiologic factors (drugs, tubes, mobilisation, oral hygiene), supportive care, and in bacterial pneumonias a specific antibiotic therapy for community-acquired or nosocomial events.

  17. Ultrasonic stir welding process and apparatus

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2009-01-01

    An ultrasonic stir welding device provides a method and apparatus for elevating the temperature of a work piece utilizing at least one ultrasonic heater. Instead of relying on a rotating shoulder to provide heat to a workpiece an ultrasonic heater is utilized to provide ultrasonic energy to the workpiece. A rotating pin driven by a motor assembly performs the weld on the workpiece. A handheld version can be constructed as well as a fixedly mounted embodiment.

  18. Imaging techniques for ultrasonic testing

    International Nuclear Information System (INIS)

    2013-01-01

    These seminar proceedings contain 16 lectures on the following topics: 1. From imaging to quantification - ultrasound methods in medical diagnostics; 2. SAFT, TOFD, Phased Array - classical applications and recent developments in ultrasonic imaging; 3. Innovative ultrasonic imaging methods in research and application; 4. Industrial ultrasonic testing of fibre-reinforced structures of complex geometry; 5. Visualisation of crack tips in the inspection of wheel set shafts with longitudinal boreholes as a means of avoiding unnecessary wheel set changes; 6. Areal analysis of the propagation of Lamb waves on curved, anisotropic structures; 7. High-resolution representation in immersion technique testing; 8. Variants in generating images from phased array measurement data - practical examples involving copper, carbon-fibre reinforced plastic and other materials; 9. GIUM - an unconventional method of microstructure imaging using ultrasonic stimulation and laser vibrometry scanning; 10. Innovative air-ultrasonic testing concepts for improved imaging; 11. Use of imaging methods for improving the quality of test results from nondestructive testing; 12. Modelling and visualisation of EMUS stimulation for transducer optimisation; 13. Use of SAFT in the manufacture of energy conversion machines; 14. Ultrasonic imaging tests for improved defect characterisation during weld seam inspection on longitudinally welded large-diameter pipes; 15. SAFT reconstruction for testing austenitic weld seams and dissimilar metal weld seams for transverse cracks; 16. Imaging-based optimisation method for quantitative ultrasonic testing of anisotropic inhomogeneous austenitic welded joints with determination and utilisation of their elastic properties. One contribution has been abstracted separately. [de

  19. Fine needle aspiration biopsy diagnosis of metastatic neoplasms of the breast. A three-case report

    Directory of Open Access Journals (Sweden)

    Raquel Garza-Guajardo

    2005-09-01

    Full Text Available Abstract Metastases to the breast are unusual lesions that make up approximately 2% of all malignant mammary neoplasms and may mimic both benign and malignant primary neoplasms from a clinical point of view, as well as in imaging studies. Arriving at a correct diagnosis is therefore essential in order to establish appropriate management. We present three cases of metastatic neoplasms diagnosed through fine needle aspiration biopsy and immunocytochemistry. The cytological diagnoses were: medulloblastoma in an 18-year-old woman, melanoma in a 26-year-old man, and an exceptional case of ovarian sarcoma originating from a granulosa cell tumor with metastases to both breasts. A metastatic disease should be considered in the differential diagnosis of a palpable mass in the breast, especially if there is a history of an extramammary malignant neoplasm. Fine needle aspiration biopsy is the method of choice for the management of these cases. Whenever possible the exam of the material obtained should be compared to the previous biopsy, which is usually enough to arrive at a correct diagnosis, thus preventing unnecessary surgical procedures.

  20. Medical versus surgical abortion efficacy, complications and leave of absence compared in a partly randomized study

    DEFF Research Database (Denmark)

    Rørbye, Christina; Nørgaard, Mogens; Nilas, Lisbeth

    2004-01-01

    To provide optimal information to women choosing between early medical and surgical abortion, rigorous comparisons of the two methods are warranted. We compared the outcome of 1135 consecutive women with gestational age (GA) ... gemeprost) or a surgical abortion (vacuum aspiration in general anesthesia). One hundred eleven of these women were randomized for abortion method. Surgical interventions and complications leading to readmission within the following 15 weeks were identified through a computer system. Information about...... antibiotic treatment, leave of absence and number of contacts to the health care system were obtained from mailed questionnaires. The number of complications was identical after the two methods, but surgical abortion was associated with a higher success rate [97.7% (708/725) vs. 94.1% (386/410), p

  1. Joint Aspiration (Arthrocentesis)

    Science.gov (United States)

    ... her in place. Explain the procedure in simple language, including where on his or her body the aspiration will be performed. After the procedure, make sure your child rests and follow any other instructions the doctor ...

  2. Correlation of gastroesophageal reflex with aspiration pneumonia after surgery

    International Nuclear Information System (INIS)

    Hirashima, Tokuji; Hashimoto, Hajime; Noro, Toshio; Takahashi, Tadao; Hino, Yasunori; Kuroiwa, Kouzirou

    1996-01-01

    In order to elucidate the correlation of gastroesophageal reflex (GER) with aspiration pneumonia after surgery, 48 patients (mean, 75.6 years) with gastric cancer treated at the hospital from March, 1994 to December, 1994 were subjected to this prospective study. The pharyngeal stimulation test, nutritional assessment, radionuclide esophageal scintigraphy (34 cases) were performed before surgery and relationship between those results and aspiration pneumonia were studied. Aspiration pneumonia occurred in 3 cases, and all of them were in, significantly, poor nutritional status, compared with other. A significant increase in the frequency of GER was observed when a naso-gastric tube (NGT) was placed, but surprisingly, all the patients with aspiration pneumonia were 3 out of 4 patients who had continuous GER without NGT. It is noteworthy, continuous GER without NGT was significantly (p<0.001) affected postoperative aspiration pneumonia and impaired phalyngeal reflex was frequently correlated with development of aspiration pneumonia, when malnutritional status existed. (author)

  3. Full-field ultrasonic inspection for a composite sandwich plate skin-core debonding detection using laser-based ultrasonics

    Science.gov (United States)

    Chong, See Yenn; Victor, Jared J.; Todd, Michael D.

    2017-04-01

    In this paper, a full-field ultrasonic guided wave method is proposed to inspect a composite sandwich specimen made for an aircraft engine nacelle. The back skin/core interface of the specimen is built with two fabricated disbond defects (diameters of 12.7 mm and 25.4 mm) by removing areas of the adhesive used to bond the back skin to the core. A laser ultrasonic interrogation system (LUIS) incorporated with a disbond detection algorithm is developed. The system consists of a 1-kHz laser ultrasonic scanning system and a single fixed ultrasonic sensor to interrogate ultrasonic guided waves in the sandwich specimen. The interest area of 400 mm × 400 mm is scanned at a 0.5 mm scan interval. The corresponding full-field ultrasonic data is obtained and generated in the three-dimensional (3-D) space-time domain. Then, the 3-D full-field ultrasonic data is Fourier transformed and the ultrasonic frequency spectra are analyzed to determine the dominant frequency that is sensitive to the disbond defects. Continuous wavelet transform (CWT) based on fast Fourier transform (FFT) is implemented as a single-frequency bandpass filter to filter the full-field ultrasonic data in the 3-D space-time domain at the selected dominant frequency. The LUIS has shown the ability to detect the disbond with diameters of 11 mm and 23 mm which match to the pre-determined disbond sizes well. For future research, a robust signal processing algorithm and a model-based matched filter will be investigated to make the detection process autonomous and improve detectability

  4. A Randomized Trial Among Compression Plus Nonsteroidal Antiinflammatory Drugs, Aspiration, and Aspiration With Steroid Injection for Nonseptic Olecranon Bursitis.

    Science.gov (United States)

    Kim, Joon Yub; Chung, Seok Won; Kim, Joo Hak; Jung, Jae Hong; Sung, Gwang Young; Oh, Kyung-Soo; Lee, Jong Soo

    2016-03-01

    Olecranon bursitis might be a minor problem in the outpatient clinic but relatively be common to occur. However, there are few well-designed studies comparing approaches to treatment. (1) Which treatment (compression bandaging with nonsteroidal antiinflammatory drugs [NSAIDs], aspiration, or aspiration with steroid injections) is associated with the highest likelihood of resolution of nonseptic olecranon bursitis? (2) Which treatment is associated with earliest resolution of symptoms? (3) What factors are associated with treatment failure by 4 weeks? We enrolled 133 patients from two centers; after applying prespecified exclusions (septic bursitis or concomitant inflammatory arthritis, intraarticular elbow pathology, recent aspiration or steroid injection done elsewhere, and refusal to participate), 90 patients were randomly allocated to receive compression bandaging with NSAIDs (C), aspiration (A), or aspiration with steroid injection (AS) groups (30 patients in each). The groups were similar at baseline in terms of age and gender. Seven patients (four from Group A and three from Group AS) were lost to followup. All patients were followed up weekly for 4 weeks, and the same treatment procedure was repeated if the bursitis recurred with any substantial fluid collection. At 4 weeks, the state of resolution and pain visual analog scale (VAS) were evaluated. Failed resolution was defined as presence of persistent olecranon bursal fluid collection at Week 4 after the initiation of the treatment; on the contrary, if bursal fluid collection was clinically reduced or completely disappeared by the end of Week 4, the treatment was considered successful. We compared the proportion of resolution by Week 4 and the median times to resolution among the treatment groups. In addition, we evaluated whether the resolution affected pain VAS and what factors were associated with the resolution. There were no differences in the proportion of patients whose bursitis resolved by Week 4

  5. Aspirated Compressors for High Altitude Engines, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Aurora Flight Sciences proposes to incorporate aspirated compressor technology into a high altitude, long endurance (HALE) concept engine. Aspiration has been proven...

  6. [Gastric aspiration therapy is a possible alternative to treatment of obesity

    DEFF Research Database (Denmark)

    Christensen, Marie Møller; Jorsal, Tina; Naver, Lars Peter Skat

    2017-01-01

    Aspiration therapy with AspireAssist is a novel endoscopic obesity treatment. Patients aspirate approximately 30% of an ingested meal through a draining system connected to a percutanous endoscopic gastrostomy tube. AspireAssist was recently approved by the US Food and Drug Administration...

  7. Aspiration Risk and Respiratory Complications in Patients with Esophageal Atresia.

    Science.gov (United States)

    Kovesi, Thomas

    2017-01-01

    Chronic, long-term respiratory morbidity (CRM) is common in patients with a history of repaired congenital esophageal atresia, typically associated with tracheoesophageal fistula (EA/TEF). EA/TEF patients are at high risk of having aspiration, and retrospective studies have associated CRM with both recurrent aspiration and atopy. However, studies evaluating the association between CRM in this population and either aspiration or atopy have reported conflicting results. Furthermore, CRM in this population may be due to other related conditions as well, such as tracheomalacia and/or recurrent infections. Aspiration is difficult to confirm, short of lung biopsy. Moreover, even within the largest evidence base assessing the association between CRM and aspiration, which has evaluated the potential relationship between gastroesophageal reflux and asthma, findings are contradictory. Studies attempting to relate CRM to prior aspiration events may inadequately estimate the frequency and severity of previous aspiration episodes. There is convincing evidence documenting that chronic, massive aspiration in patients with repaired EA/TEF is associated with the development of bronchiectasis. While chronic aspiration is likely associated with other CRM in patients with repaired EA/TEF, this does not appear to have been confirmed by the data currently available. Prospective studies that systematically evaluate aspiration risk and allergic disease in patients with repaired EA/TEF and document subsequent CRM will be needed to clarify the causes of CRM in this population. Given the prevalence of CRM, patients with repaired EA/TEF should ideally receive regular follow-up by multidisciplinary teams with expertise in this condition, throughout both childhood and adulthood.

  8. [A retrospective clinicopathological study of aspiration pneumonia in the elderly].

    Science.gov (United States)

    Pu, Chun; Zhong, Xuefeng; Fang, Fang; Yang, Yimeng; Xu, Xiaomao; Sun, Tieying

    2014-08-01

    To explore the clinicopathological characteristics of aspiration pneumonia in the elderly. The clinical data of 30 cases of autopsy-proven aspiration pneumonia in Beijing Hospital from 1973 to 2002 were reviewed. The patients consisted of 28 males and 2 females, aged from 63 to 103 [mean (83 ± 9)] years. Only 15 cases were clinically diagnosed as aspiration pneumonia before death. Concomitant diseases were severe and complex, mostly coronary disease, cerebrovascular disease, hypertension, COPD, and diabetes mellitus. All the patients suffered from at least 3 concomitant diseases. Long-term bedridden and nasogastric feeding was seen in 11 and 17 patients respectively. The clinical presentation and chest X-ray of aspiration pneumonia in the elderly were nonspecific and variable. Mixed infections were common . The main bacteria isolated were Gram-negative bacilli, in particular Pseudomonas aeruginosa, Stenotrophomonas maltophilia, Escherichia coli and Candida albicans. By pathology, macrophages with foreign bodies were found in all the 30 cases and multiple small abscesses were found in 14 cases. The lesions were adjacent to the bronchioles and in the lung tissue around the bronchioles, mostly multi-lobar and bilateral. Unilateral or bilateral pleural effusion developed in 20 patients. The accordance between radiological and pathological diagnosis of aspiration pneumonia was very poor. The foci of infection detected by X-ray were proven by autopsy in 13 patients, while pleural effusions in X-ray were proven by autopsy in 15 patients. Multi-concomitant diseases, mixed infection and extra-pulmonary presentations were common in elderly patients with aspiration pneumonia. Multiple small abscesses were the pathological characteristics of aspiration pneumonia in the aged. A definite clinical diagnosis of aspiration pneumonia was difficult. Recurrent silent microaspiration was a feature of aspiration in the elderly. The assessment of risk factor of aspiration played an

  9. Ultrasonic Bat Deterrent Technology

    Energy Technology Data Exchange (ETDEWEB)

    Kinzie, Kevin; Rominger, Kathryn M.

    2017-12-14

    The project objective was to advance the development and testing of an Near commercial bat-deterrent system with a goal to increase the current GE deterrent system effectiveness to over 50% with broad species applicability. Additionally, the research supported by this program has provided insights into bat behavior and ultrasonic deterrent design that had not previously been explored. Prior research and development had demonstrated the effectiveness of a commercial-grade, air-powered, ultrasonic bat deterrent to be between 30-50% depending upon the species of bat. However, the previous research provided limited insight into the behavioral responses of bats in the presence of ultrasonic deterrent sound fields that could be utilized to improve effectiveness. A unique bat flight room was utilized to observe the behavioral characteristics of bats in the presence of ultrasonic sound fields. Behavioral testing in the bat flight facility demonstrated that ultrasonic sounds similar to those produced by the GE deterrent influenced the activities and behaviors, primarily those associated with foraging, of the species exposed. The study also indicated that continuous and pulsing ultrasonic signals had a similar effect on the bats, and confirmed that as ultrasonic sounds attenuate, their influence on the bats’ activities and behavior decreases. Ground testing at Wolf Ridge Wind, LLC and Shawnee National Forest assessed both continuous and pulsing deterrent signals emitted from the GE deterrent system and further enhanced the behavioral understanding of bats in the presence of the deterrent. With these data and observations, the existing 4-nozzle continuous, or steady, emission ultrasonic system was redesigned to a 6-nozzle system that could emit a pulsing signal covering a larger air space around a turbine. Twelve GE 1.6-100 turbines were outfitted with the deterrent system and a formal three-month field study was performed using daily carcass searches beneath the 12

  10. Quality control of disinfection in ultrasonic baths

    Energy Technology Data Exchange (ETDEWEB)

    Schoene, H. [Technical University Dresden (Germany). Faculty of Mechanical Engineering; Jatzwauk, L. [University Hospital of the Technical University Dresden (Germany). Abt. Krankenhaushygiene

    2002-07-01

    Numerous investigations under laboratory conditions confirmed the microbicidal efficacy of ultrasonication. Morphological destruction was shown on bacteria and fungi as well as on different virus species. Ultrasonic treatment seems to increase the effect of different antibiotics and disinfectants. Reasons for this synergism are largely unknown and uninvestigated, but the active principle seems to bee the dispersing effect of ultrasonication in combination with the destruction of cell wall or cell membrane. Unfortunately no validation of test conditions exists for most of these investigations, regarding intensity and frequency of ultrasonic waves, temperature of liquid medium and measurement of cavitation which is an essential part of physical and chemical effects in ultrasonic baths. In contrast to most laboratory experiments sound density of ultrasound for treatment of medical instruments is below 1 W/cm{sup 2} because instruments will be destroyed under stronger ultrasonic conditions. The frequency is below 50 KHz. This paper describes bactericidal and fungicidal effects of low- intensity-ultrasonication and its synergistical support to chemical disinfection. (orig.)

  11. Development and Application of an Ultrasonic Gas Flowmeter

    International Nuclear Information System (INIS)

    Hwang, Won Ho; Jeong, Hee Don; Park, Sang Gug; Jhang, Kyung Young

    2002-01-01

    This paper describes the development and the field application of the ultrasonic gas flowmeter for accurate measurement of the volumetric flow rate of gases in a harsh environmental conditions in iron and steel making company. This ultrasonic flowmeter is especially suited for measuring LDG, COG, BFG gases produced in iron and steel making process. This is a transit time type ultrasonic flowmeter. We have developed the transmitting and receiving algorithm of ultrasonic wave and the ultrasonic signal processing algorithm to develope a transit time type ultrasonic flowmeter. We have evaluated the performance of ultrasonic flowmeter by the calibration system with Venturi type standard flowmeter. We has confirmed its reliability by extensive field tests for a year in POSCO, iron and steel making company. Now we have developed the commercial model of ultrasonic flowmeter and applied to the POSCO gas line

  12. Ultrasonic Tomography Imaging for Liquid-Gas Flow Measurement

    Directory of Open Access Journals (Sweden)

    Muhammad Jaysuman PUSPPANATHAN

    2013-01-01

    Full Text Available This research was carried out to measure two-phase liquid – gas flow regime by using a dual functionality ultrasonic transducer. Comparing to the common separated transmitter–receiver ultrasonic pairs transducer, the dual functionality ultrasonic transceiver is capable to produce the same measurable results hence further improvises and contributes to the hardware design improvement and system accuracy. Due to the disadvantages and the limitations of the separated ultrasonic transmitter–receiver pair, this paper presents a non-invasive ultrasonic tomography system using ultrasonic transceivers as an alternative approach. Implementation of ultrasonic transceivers, electronic measurement circuits, data acquisition system and suitable image reconstruction algorithms, the measurement of a liquid/gas flow was realized.

  13. Fine needle aspiration cytology of cervicofacial actinomycosis

    Directory of Open Access Journals (Sweden)

    Venkatesh Kusuma

    2008-01-01

    Full Text Available Actinomycosis is a chronic infection caused by Actinomyces israelii, usually seen in immunocompromised patients or in the background of tissue injury. Cervicofacial actinomycosis presenting as a fixed jaw swelling in an elderly individual can mimic malignancy and pose a diagnostic dilemma. We report here a case of cervicofacial actinomycosis diagnosed by fine needle aspiration, along with a review of the relevant literature. A 60 year-old man presented with a gradually increasing 6 x 5 cm swelling in the left side of his jaw. The swelling was fixed, without any apparent sinus or abscess. Fine needle aspiration was diagnostic as it revealed colonies of actinomyces surrounded by polymorphs and chronic inflammatory cells. The histopathological study of the excised specimen confirmed the cytological findings. Fine needle aspiration is an effective tool in the diagnosis of actinomycosis although its documentation is rare. Difficulties in the management can be avoided by early diagnosis using the fine needle aspiration technique.

  14. Ultrasonic Stir Welding

    Science.gov (United States)

    Nabors, Sammy

    2015-01-01

    NASA Marshall Space Flight Center (MSFC) developed Ultrasonic Stir Welding (USW) to join large pieces of very high-strength metals such as titanium and Inconel. USW, a solid-state weld process, improves current thermal stir welding processes by adding high-power ultrasonic (HPU) energy at 20 kHz frequency. The addition of ultrasonic energy significantly reduces axial, frictional, and shear forces; increases travel rates; and reduces wear on the stir rod, which results in extended stir rod life. The USW process decouples the heating, stirring, and forging elements found in the friction stir welding process allowing for independent control of each process element and, ultimately, greater process control and repeatability. Because of the independent control of USW process elements, closed-loop temperature control can be integrated into the system so that a constant weld nugget temperature can be maintained during welding.

  15. [Gastric aspiration therapy is a possible alternative to treatment of obesity

    DEFF Research Database (Denmark)

    Christensen, Marie Møller; Jorsal, Tina; Naver, Lars Peter Skat

    2017-01-01

    Aspiration therapy with AspireAssist is a novel endoscopic obesity treatment. Patients aspirate approximately 30% of an ingested meal through a draining system connected to a percutanous endoscopic gastrostomy tube. AspireAssist was recently approved by the US Food and Drug Administration, and it......-term effects are warranted....

  16. Development of coaxial ultrasonic probe for fatty liver diagnostic system using ultrasonic velocity change

    Science.gov (United States)

    Hori, Makoto; Yokota, Daiki; Aotani, Yuhei; Kumagai, Yuta; Wada, Kenji; Matsunaka, Toshiyuki; Morikawa, Hiroyasu; Horinaka, Hiromichi

    2017-07-01

    A diagnostic system for fatty liver at an early stage is needed because fatty liver is linked to metabolic syndrome. We have already proposed a fatty liver diagnosis method based on the temperature coefficient of ultrasonic velocity. In this study, we fabricated a coaxial ultrasonic probe by integrating two kinds of transducers for warming and signal detection. The diagnosis system equipped with the coaxial probe was applied to tissue-mimicking phantoms including the fat area. The fat content rates corresponding to the set rates of the phantoms were estimated by the ultrasonic velocity-change method.

  17. Fine-needle aspiration findings of a rare hematopoietic neoplasm presenting as obstructive jaundice.

    Science.gov (United States)

    Tracht, Jessica; Ahmed, Ali M; Rosenblum Donath, Frida

    2017-12-01

    A 51-year-old female who presented with obstructive jaundice was found to have masses in the pancreatic head and tail as well as suspicious liver and periaortic masses on imaging. Aspiration cytology of the pancreatic tail mass showed abundant large single cells with vacuolated eosinophilic cytoplasm, marked nuclear pleomorphism, large bizarre irregular nuclei, binucleation, and prominent nucleoli. Numerous cells also showed intracytoplasmic black to brown pigmentation. A cell block was obtained and extensive immunohistochemical staining was performed. S-100, HMB-45, Sox10, pancytokeratin, CK7, RCC antigen, synaptophysin, HepPar 1, inhibin, CD45, CD21, and CD123 were negative, making melanoma, epithelial malignancies, lymphoma, follicular dendritic and plasmacytoid dendritic cell neoplasms less likely. CD4 and CD56 showed partial positivity, and CD68, CD163, and CD14 were positive, supporting the diagnosis of histiocytic sarcoma. Surgical specimens and immunohistochemistry confirmed the cytologic findings. Histiocytic sarcoma is a rare aggressive malignancy of histiocytic origin with most cases presenting in adults in extranodal sites, most commonly the intestinal tract. Few cases are reported in the literature, presenting diagnostic challenges for cytopathologists when seen on fine-needle aspiration. We present the first reported case of histiocytic sarcoma presenting as a pancreatic mass, diagnosed by endoscopic ultrasound guided fine-needle aspiration (EUS-FNA). This entity is rarely described on cytology and arose in a location in which EUS-FNA is the diagnostic modality of choice. This case study highlights that cytopathologists should be aware of histiocytic sarcoma occurring in extranodal locations accessible by EUS-FNA and be familiar with the cytomorphologic appearance. © 2017 Wiley Periodicals, Inc.

  18. Gender and Leadership Aspiration : The Impact of the Organizational Environment

    NARCIS (Netherlands)

    C. Fritz (Claudia)

    2016-01-01

    markdownabstractSummary The aim of this dissertation is to examine gender differences in leadership aspiration. Although some important work regarding gender-specific aspiration has been done already, conditions fostering leadership aspiration – particularly among women – are not completely

  19. On the possible ultrasonic inspection of micro-bubbles generated by the optical fiber tip

    Directory of Open Access Journals (Sweden)

    V. V. Kazakov

    2016-09-01

    Full Text Available We demonstrate the possibility of detection and monitoring of bubbles emerging near the tip of an optical fiber by means of ultrasonic method. The excitation of bubbles at their resonant frequencies is performed using short ultrasonic pulses having a wide frequency range simultaneously with their modulation by means of a long pulse of a monochromatic frequency. This method allows detection of bubbles of various sizes. Used signal processing method, which allows increased bubble detection accuracy, is proposed for research in environments of biological-like medium which show continuous variations in structure and properties when exposed to optical emission. The method has been demonstrated on model objects: in a liquid and in a biological tissue phantom using various methods of bubble generation (hydrolysis and optical emission. We studied bubble formation by the tip of a fiber of the surgical laser LSP-007/10 “IRE Polus” with a wavelength of 0.97μm coated with a highly absorbing graphite layer.

  20. Pitch-catch only ultrasonic fluid densitometer

    Science.gov (United States)

    Greenwood, M.S.; Harris, R.V.

    1999-03-23

    The present invention is an ultrasonic fluid densitometer that uses a material wedge and pitch-catch only ultrasonic transducers for transmitting and receiving ultrasonic signals internally reflected within the material wedge. Density of a fluid is determined by immersing the wedge into the fluid and measuring reflection of ultrasound at the wedge-fluid interface. 6 figs.

  1. AstroBiology Explorer Mission Concepts (ABE/ASPIRE)

    Science.gov (United States)

    Sandford, Scott; Ennico, Kimberly A.

    2006-01-01

    The AstroBiology Explorer (ABE) and the Astrobiology Space InfraRed Explorer (ASPIRE) Mission Concepts are two missions designed to address the questions (1) Where do we come from? and (2) Are we alone? as outlined in NASA s Origins Program using infrared spectroscopy to explore the identity, abundance, and distribution of molecules of astrobiological importance throughout the Universe. The ABE mission s observational program is focused on six tasks to: (1) Investigate the evolution of ice and organics in dense clouds and star formation regions, and the young stellar/planetary systems that form in them; (2) Measure the evolution of complex organic molecules in stellar outflows; (3) Study the organic composition of a wide variety of solar system objects including asteroids, comets, and the planets and their satellites; (4) Identify organic compounds in the diffuse interstellar medium and determine their distribution , abundance, and change with environment; (5) Detect and identify organic compounds in other galaxies and determine their dependence on galactic type; and (6) Measure deuterium enrichments in interstellar organics and use them as tracers of chemical processes. The ASPIRE mission s observational program expands upon ABE's core mission and adds tasks that (7) Address the role of silicates in interstellar organic chemistry; and (8) Use different resolution spectra to assess the relative roles and abundances of gas- and solid-state materials. ABE (ASPIRE) achieves these goals using a highly sensitive, cryogenically-cooled telescope in an Earth drift-away heliocentric orbit, armed with a suite of infrared spectrometers that cover the 2.5-20(40) micron spectral region at moderate spectral resolution (R>2000). ASPIRE's spectrometer complement also includes a high-resolution (R>25,000) module over the 4-8 micron spectral region. Both missions target lists are chosen to observe a statistically significant sample of a large number of objects of varied types in

  2. Fine needle aspiration cytology of bone tumours- the experience from the National Orthopaedic and Lagos University Teaching Hospitals, Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Nnodu Obiageli E

    2006-06-01

    Full Text Available Abstract Background Due to difficulty in confirming clinical suspicions of malignancy in patients presenting with bone tumours, the cost of surgical biopsies where hospital charges are borne almost entirely by patients, competition with bone setters and healing homes with high rate of loss to follow up; we set out to find if sufficient material could be obtained to arrive at reliable tissue diagnosis in patients with clinical and radiological evidence of bone tumours in our hospitals. Methods After initial clinical and plain radiographic examinations, patients were sent for fine needle aspirations. Aspirations were carried out with size 23G needles of varying lengths with 10 ml syringes in a syringe holder (CAMECO, Sebre Medical, Vellinge, Sweden. The aspirates were air dried, stained by the MGG method and examined microscopically. Histology was performed on patients who had subsequent surgical biopsy. These were then correlated with the cytology reports. Results Out of 96 patients evaluated, [57 males, 39 females, Mean age 31.52 years, Age Range 4–76 years,] material sufficient for diagnosis was obtained in 90 patients. Cytological diagnosis of benign lesions was made in 40 patients and malignant in 47. Of these, 27 were metastases, osteogenic sarcoma 16, giant cell tumour 19, infection 11. Histology was obtained in 41 patients. Correct diagnosis of benignity was made in 17 out of 18 cases, malignancy in 21 out of 22 cases. One non-diagnostic case was malignant. The accuracy of specific cytological diagnosis was 36/41 (87.8% and incorrect in 5/41 (12.2%. Conclusion We conclude that FNAC can be useful in the pre-operative assessment of bone tumours especially where other diagnostic modalities are unavailable.

  3. A reformed surgical treatment modality for children with giant cystic craniopharyngioma.

    Science.gov (United States)

    Zhu, Wanchun; Li, Xiang; He, Jintao; Sun, Tao; Li, Chunde; Gong, Jian

    2017-09-01

    Surgical removal plays an important role in treating children's craniopharyngioma. For a safe and minimally invasive craniotomy, a reformed surgical modality was proposed in this paper by combining the insertion of an Ommaya reservoir system (ORS) by stereotactic puncture, aspiration of cystic fluid in 2-day interval for consecutive 7-10 days, and the delayed tumor resection. Eleven patients (aged from 5 to 9 years old) with giant cystic craniopharyngiomas who had undergone the reformed surgical modality during November 2014 and December 2015 were collected as group A. In contrast, seven patients (aged from 5 to 11 years old) who had undergone the traditional directed operation without any prior management from January 2014 to October 2014 were collected into group B. A retrospective analysis was performed for both groups at one institution. The preoperative and postoperative clinical presentations, neuroimaging, early postoperative outcome, and the surgery-related complications of both groups were reviewed. For group A, the mean value of the maximum tumor diameters shank from 52.36 to 23.82 mm after implementing aspiration of the cystic fluid in 1-day interval for consecutive 8.23 days. Eight patients (72.73%) in group A underwent a gross total resection (GTR), while two (28.57%) patients underwent GTR in group B. The postoperative electrolyte disturbance rate and endocrine disorder rate of group B were significantly higher than those of group A (42.86 vs 36.36%; 71.43 vs 45.45%). Postoperative long-term diabetes insipidus only occurred in one patient of group B, and postoperative visual deterioration occurred in two patients of group B. Besides, one patient of group B died of severe postoperative hypothalamus dysfunction. Patients with residual tumors were applied with additional adjuvant radiotherapy, and no recurrence was observed in follow-up examinations. A favorable outcome can be achieved by combining the insertion of an ORS by stereotactic puncture

  4. Under sodium ultrasonic imaging system for PFBR

    International Nuclear Information System (INIS)

    Patankar, V.H.; Lalwani, S.K.; Agashe, A.A.

    2014-01-01

    Under Sodium UltraSonic Scanner (USUSS) has been developed to detect the growth and protrusion of fuel sub-assemblies of PFBR, submerged in liquid sodium by using the ultrasonic imaging technique during reactor shut-down when liquid sodium is at 180 ℃. The imaging is carried out prior to every Fuel handling operation. Electronics Division, BARC has designed and developed an 8-Channel Ultrasonic Imaging System (UIS) which consists of 4 downward viewing and 4 side viewing ultrasonic transducers alongwith pulser-receiver, signal processing electronics hardware and software. An automated mechanical scanner developed by IGCAR houses sodium immersible transducers to image the fuel sub assemblies. The system has been successfully tested with dummy protruding and grown FSAs, submerged under liquid sodium. Such ultrasonic imaging systems are not available to India from international market. The USUSS developed indigenously has all the features available in similar systems developed by other countries. After every imaging campaign, the mechanical scanner containing ultrasonic transducers is stored in the Argon filled storage-pit. Before every campaign of USUSS, it is necessary to check the healthiness of the sodium immersible and contaminated ultrasonic transducers, as the under-sodium scanner is decontaminated once in five years. For this purpose, a novel Non Contact Ultrasonic Inspection System (NCUIS) has been designed and developed by Electronics Division, BARC to check the functionality of the high-temperature and contaminated transducers of USUSS, using air-coupled ultrasonic technique. (author)

  5. Ultrasonic Linear Motor with Two Independent Vibrations

    Science.gov (United States)

    Muneishi, Takeshi; Tomikawa, Yoshiro

    2004-09-01

    We propose a new structure of an ultrasonic linear motor in order to solve the problems of high-power ultrasonic linear motors that drive the XY-stage for electron beam equipment and to expand the application fields of the motor. We pay special attention to the following three points: (1) the vibration in two directions of the ultrasonic linear motor should not influence mutually each other, (2) the vibration in two directions should be divided into the stage traveling direction and the pressing direction of the ultrasonic linear motor, and (3) the rigidity of the stage traveling direction of the ultrasonic linear motor should be increased. As a result, the supporting method of ultrasonic linear motors is simplified. The efficiency of the motor is improved and temperature rise is reduced. The stage position drift is also improved.

  6. CT guided puncture aspiration and sclerosing treatment of ovary cyst

    International Nuclear Information System (INIS)

    Peng Yongjun; Du Xiumei; Yuan Jinrong; Chen Chanqing

    2007-01-01

    Objective: To analyze the method and the curative effect with CT guided percutaneous puncture aspiration and sclerosing treatment of ovary cyst. Method: 22 ovary cysts in 22 patients were treated with percutaneous puncture aspiration and underwent repeated sclerotherapy with 99.7% ethanol injection. Among the 22 patients, 18 patients had solitary ovary cyst and was aspirated with an 18-22G gauge aspiration needle. The amount of aspirated fluid varied from 30ml-500ml and 25%-30% cyst volume was replaced by appropriate ethanol Post treatment follow-up were achieved every 3 months. Results All the Punctures were successfully completed. During the 3 months to one year follow-up, 16 ovary cyst disappeared, 6 cysts were small over 50%, without main complication. Conclusion CT guided percutaneous puncture aspiration and sclerosing treatment of ovary cyst is a treatment of choice because of its safety, low complication, and high curative effect. (authors)

  7. Surgical rehabilitation of patients with spinal neurotrophic decubitus

    Directory of Open Access Journals (Sweden)

    S. G. Shapovalov

    2016-01-01

    Full Text Available The greatest weight neurodystrophic process develops in traumatic spinal cord injury, appears as neurotrophic decubitus (bedsores. There is a high risk of wound infection in the event of pressure ulcers. Surgical repair of the skin integrity in spinal patients of 3 and 4 grade is a basic prerequisite for the further complex of the rehabilitation measures. Work objective: to develop the concept of innovative technologies of treatment of local physical impacts and to implement it in surgical system of rehabilitation of patients with spinal cord lesion with neurotrophic decubitus of 3 and 4 grade. Clinical studies subjected 49 (100% patients with spinal cord lesions and neurotrophic decubitus of 3 and 4 grade. All patients were divided into two groups: 1– (study group 1 29 patients; 2 – (control group 2 20 patients. The managed negative pressure system S042 NPWT VivanoTec (Hartmann, a method of ultrasonic cavitation (Sonoca%180, the system for the hydro surgery Versajet Smith and Nephew were used in the 1%st group. Traditional dressings for the preparation of a plastic closure of the wound defect neurotrophic decubitus of the grade 3%4 were used in the 2nd group. Statistical analysis was performed using package of Microsoft Excel%97 Statistica for Windows 6.0, SPSS 10.0 for Windows. The study showed that the use of complex methods of vacuum therapy, ultrasound cavitation and hydro surgical in the 1st group significantly reduces the duration of treatment compared with conservative methods in the 2nd group. In group 1, the mean duration of treatment was 19.9±13.9 days, in group 2 (comparison group – 40.0±28.2 days (p<0.05. The usage of physical methods (managed negative pressure system, ultrasonic processing method, hydro surgical system local treatment is a highly effective method of preparation neurotrophic decubitus grade 3 and 4 to the early recovery of the skin. Physical methods of local treatment have a positive effect on tissue

  8. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women

    Science.gov (United States)

    Leicht, Carola; Gocłowska, Małgorzata A.; Van Breen, Jolien A.; de Lemus, Soledad; Randsley de Moura, Georgina

    2017-01-01

    Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1) counter-stereotype salience and (2) feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women (N = 208) attended to gender stereotypic (vs. counter-stereotypic) content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes) significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations. PMID:28626437

  9. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women.

    Science.gov (United States)

    Leicht, Carola; Gocłowska, Małgorzata A; Van Breen, Jolien A; de Lemus, Soledad; Randsley de Moura, Georgina

    2017-01-01

    Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1) counter-stereotype salience and (2) feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women ( N = 208) attended to gender stereotypic (vs. counter-stereotypic) content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes) significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations.

  10. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women

    Directory of Open Access Journals (Sweden)

    Carola Leicht

    2017-06-01

    Full Text Available Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1 counter-stereotype salience and (2 feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women (N = 208 attended to gender stereotypic (vs. counter-stereotypic content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations.

  11. Aspiration dynamics of multi-player games in finite populations.

    Science.gov (United States)

    Du, Jinming; Wu, Bin; Altrock, Philipp M; Wang, Long

    2014-05-06

    On studying strategy update rules in the framework of evolutionary game theory, one can differentiate between imitation processes and aspiration-driven dynamics. In the former case, individuals imitate the strategy of a more successful peer. In the latter case, individuals adjust their strategies based on a comparison of their pay-offs from the evolutionary game to a value they aspire, called the level of aspiration. Unlike imitation processes of pairwise comparison, aspiration-driven updates do not require additional information about the strategic environment and can thus be interpreted as being more spontaneous. Recent work has mainly focused on understanding how aspiration dynamics alter the evolutionary outcome in structured populations. However, the baseline case for understanding strategy selection is the well-mixed population case, which is still lacking sufficient understanding. We explore how aspiration-driven strategy-update dynamics under imperfect rationality influence the average abundance of a strategy in multi-player evolutionary games with two strategies. We analytically derive a condition under which a strategy is more abundant than the other in the weak selection limiting case. This approach has a long-standing history in evolutionary games and is mostly applied for its mathematical approachability. Hence, we also explore strong selection numerically, which shows that our weak selection condition is a robust predictor of the average abundance of a strategy. The condition turns out to differ from that of a wide class of imitation dynamics, as long as the game is not dyadic. Therefore, a strategy favoured under imitation dynamics can be disfavoured under aspiration dynamics. This does not require any population structure, and thus highlights the intrinsic difference between imitation and aspiration dynamics.

  12. How useful is gastroesophageal reflux scintigraphy in suspected childhood aspiration?

    International Nuclear Information System (INIS)

    Fawcett, H.D.; Adams, J.C.; Hayden, C.K.; Swischuk, L.E.

    1988-01-01

    It has been suggested that gastroesophageal reflux scintigraphy might be useful in assisting one in determining therapy for patients suspected of aspirating or becoming apneic secondary to gastroesophageal reflux. This, however, has not been our experience and in reviewing 23 patients with recurrent pneumonia and/or apnea who had gastroesophageal reflux scintigraphy, we were able to detect aspiration in only one. This was especially significant since 13 (59%) of these patients had demonstrable reflux, and of these, eight were treated successfully for suspected aspiration even though none was demonstrated isotopically. To be sure, the demonstration of pulmonary aspiration with gastroesophageal reflux scintigraphy had little influence on patient selection and response to therapy. For this reason we feel there is little justification in depending on the GRS for the specific purpose of trying to document pulmonary aspiration in infants and children who are refluxing. One of the more serious complications of gastroesophageal (GE) reflux is aspiration leading to recurrent pulmonary infections and/or apnea. However, it always has been difficult to demonstrate actual aspiration into the lungs, and to be sure, barium studies of the upper GI tract seldom reveal this complication. Recently, however, considerable interest has been generated in gastroesophageal scintigraphy (GRS) as a possible means of documenting such aspiration. Rationale for this stems from the fact that suspected patients can be studied over a longer period of time and in addition, delayed and overnight images can be obtained. However, our experience does not support GRS as being an adequate method for demonstrating aspiration. (orig.)

  13. How useful is gastroesophageal reflux scintigraphy in suspected childhood aspiration

    Energy Technology Data Exchange (ETDEWEB)

    Fawcett, H.D.; Adams, J.C.; Hayden, C.K.; Swischuk, L.E.

    1988-05-01

    It has been suggested that gastroesophageal reflux scintigraphy might be useful in assisting one in determining therapy for patients suspected of aspirating or becoming apneic secondary to gastroesophageal reflux. This, however, has not been our experience and in reviewing 23 patients with recurrent pneumonia and/or apnea who had gastroesophageal reflux scintigraphy, we were able to detect aspiration in only one. This was especially significant since 13 (59%) of these patients had demonstrable reflux, and of these, eight were treated successfully for suspected aspiration even though none was demonstrated isotopically. To be sure, the demonstration of pulmonary aspiration with gastroesophageal reflux scintigraphy had little influence on patient selection and response to therapy. For this reason we feel there is little justification in depending on the GRS for the specific purpose of trying to document pulmonary aspiration in infants and children who are refluxing. One of the more serious complications of gastroesophageal (GE) reflux is aspiration leading to recurrent pulmonary infections and/or apnea. However, it always has been difficult to demonstrate actual aspiration into the lungs, and to be sure, barium studies of the upper GI tract seldom reveal this complication. Recently, however, considerable interest has been generated in gastroesophageal scintigraphy (GRS) as a possible means of documenting such aspiration. Rationale for this stems from the fact that suspected patients can be studied over a longer period of time and in addition, delayed and overnight images can be obtained. However, our experience does not support GRS as being an adequate method for demonstrating aspiration.

  14. Pulsed ultrasonic stir welding method

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2013-01-01

    A method of performing ultrasonic stir welding uses a welding head assembly to include a plate and a rod passing through the plate. The rod is rotatable about a longitudinal axis thereof. In the method, the rod is rotated about its longitudinal axis during a welding operation. During the welding operation, a series of on-off ultrasonic pulses are applied to the rod such that they propagate parallel to the rod's longitudinal axis. At least a pulse rate associated with the on-off ultrasonic pulses is controlled.

  15. Ultrasonic tests. Pt. 2

    International Nuclear Information System (INIS)

    Goebbels, K.

    1980-01-01

    After a basic treatment of ultrasonic wave propagation, of the state-of-the-art methods and the technical background in the preceeding part, advanced ultrasonic NDT techniques are presented here. The discussion of new development includes - manipulation systems, - automation of ultrasonic testing methods, documentation and evaluation. In the middle of this part the main problem areas will be discussed: - detection of defects (e.g. in coarse grained structures and welds), - classification of defects (e.g. discrimination between crack-like and volumetric faults), - sizing of defects. Research in the field of acoustical holography, development of probes and phased arrays, electromagnetic acoustic transducers and signal enhancement are the main contributing parts to the report. (orig./RW)

  16. Aspiration, Localized Pulmonary Inflammation, and Predictors of Early-Onset Bronchiolitis Obliterans Syndrome after Lung Transplantation

    Science.gov (United States)

    Fisichella, P Marco; Davis, Christopher S; Lowery, Erin; Ramirez, Luis; Gamelli, Richard L; Kovacs, Elizabeth J

    2014-01-01

    of IL-15, IL-17, basic fibroblast growth factor, tumor necrosis factor–α, myeloperoxidase, and α1-antitrypsin at 6 to 12 months after lung transplantation are predictive of early-onset BOS, and those with BOS and aspiration have an augmented chemotactic and inflammatory balance of pulmonary leukocytes and immune mediators. These data justify the surgical prevention of aspiration and argue for the refinement of antirejection regimens. PMID:23628225

  17. Diagnostic Accuracy and Pitfalls of Preoperative Fine Needle Aspiration Cytology in Salivary Gland Lesions

    International Nuclear Information System (INIS)

    TAHOUN, N.; EZZAT, N.

    2008-01-01

    Purpose: Evaluation of diagnostic accuracy of preoperative fine needle aspiration cytology (FNAC) in salivary gland lesions. Patients and Methods: This is a retrospective study of 82 patients presented at NCI, Cairo University with salivary gland lesion who underwent preoperative FNAC diagnosis with subsequent excision and histopathologic assessment. Cytology results were classified as negative, positive, suspicious for cancer and inadequate. The definitive histopathologic report according to WHO Histological typing was the gold standard diagnosis against which FNAC was compared. Results: Our study included 82 patients who underwent preoperative FNAC of major salivary glands with subsequent surgical excision. Male to female ratio was 1.4: 1. The median age was 42 years. Parotid gland was involved in (68.3%), submandibular in (28%) and sub mental gland in (3.7%). Forty cases (48.8%) were cytologically diagnosed as benign lesions, 26 (31.7%) were malignant and 10 (12.2%) were suspicious. Cytological findings were non diagnostic in 6 (7.3%). The most common benign cytologic diagnosis was pleomorphic adenoma; 16 out of 40 cases (40%), while the most common malignant tumor was carcinoma; 22 out of 26 cases (84.6%). Cytologic diagnoses were compared with histopathologic ones and were true-negative in 37 (92.5%), true-positive in 33 (91.6%), false-negative in 3 (8.3%) and false-positive in 3 (7.5%) cases regarding detection of malignant tumors. The cytologic diagnosis achieved a sensitivity of 91.7%; a specificity of 92.5%, PPV 91.6%, NPV 92.5% and diagnostic accuracy 92%. The rates of agreement of histopathologic type for benign and malignant tumors were 89.2% and 91%, respectively. Conclusion: The sensitivity, specificity and diagnostic accuracy of FNAC were 91.7%, 92.5% and 92%, respectively. Attention to subtle morphologic changes, pitfalls and limitations are important to increase diagnostic accuracy. Multidirectional aspiration is preferred to avoid selective

  18. Surgical techniques to minimize shoulder pain after laparoscopic cholecystectomy

    DEFF Research Database (Denmark)

    Donatsky, Anders Meller; Bjerrum, Flemming; Gögenür, Ismayil

    2013-01-01

    intraoperative surgical methods applied to minimize incidence or severity of SP after LC. Only papers published in English were included. Data extracted were year of publication, number of participants and allocation, nonsignificant or significant effect on incidence or severity of SP. RESULTS: A total of 31...... papers where included in the review. Seven, 8, and 12 papers investigated the effect of drains, abdominal wall lift (AWL), and low-pressure pneumoperitoneum respectively. Four papers investigated drain suction, active gas aspiration, low insufflation flow or N(2)O insufflation respectively...

  19. Aspiration of Barium Contrast

    Directory of Open Access Journals (Sweden)

    Cristina Fuentes Santos

    2014-01-01

    Full Text Available The aspiration of barium contrast is a rare complication that may occur during studies of the digestive tract. Barium is an inert material that can cause anywhere from an asymptomatic mechanical obstruction to serious symptoms of respiratory distress that can result in patient death. We present the case of a 79-year-old male patient in whom we observed the presence of contrast medium residue in the lung parenchyma as an incidental finding during hospitalization. When the patient’s medical file was reviewed, images were found of a barium swallow study that the patient had undergone months earlier, and we were able to observe the exact moment of the aspiration of the contrast material. The patient had been asymptomatic since the test.

  20. Detailed simulation of ultrasonic inspections

    International Nuclear Information System (INIS)

    Chaplin, K.R.; Douglas, S.R.; Dunford, D.

    1997-01-01

    Simulation of ultrasonic inspection of engineering components have been performed at the Chalk River Laboratories of AECL for over 10 years. The computer model, called EWE for Elastic Wave Equations, solves the Elastic Wave Equations using a novel finite difference scheme. It simulates the propagation of an ultrasonic wave from the transducer to a flaw, the scatter of waves from the flaw, and measurement of signals at a receive transducer. Regions of different materials, water and steel for example, can be simulated. In addition, regions with slightly different material properties from the parent material can be investigated. The two major types of output are displays of the ultrasonic waves inside the component and the corresponding A-scans. EPRI and other organizations have used ultrasonic models for: defining acceptable ultrasonic inspection procedures, designing and evaluating inspection techniques, and for quantifying inspection reliability. The EWE model has been applied to the inspection of large pipes in a nuclear plant, gas pipeline welds and steam generator tubes. Most recent work has dealt with the ultrasonic inspection of pressure tubes in CANDU reactors. Pressure tube inspections can reliably detect and size defects; however, there are improvements that can be made. For example, knowing the sharpness of a flaw-tip is crucial for fitness for service assessments. Computer modelling of the ultrasonic inspection of flaws with different root radius has suggested inspection techniques that provide flaw tip radius information. A preliminary investigation of these methods has been made in the laboratory. The basis for the model will be reviewed at the presentation. Then the results of computer simulations will be displayed on a PC using an interactive program that analyzes simulated A-scans. This software tool gives inspection staff direct access to the results of computer simulations. (author)

  1. The effects of ultrasonic solidification on aluminum

    OpenAIRE

    Đorđević Slavko 1

    2003-01-01

    The effect of ultrasound on characteristics of solidified aluminum was shown. An ultrasonic head and ultrasonic system for modification was designed and applied to the crystallizing aluminum melt. The ultrasonic generator allows power of 50-500 W, amplitude of oscillations 10-100 um.m and the operating frequency of 25 kHz. Ultrasonic modification was done by ultrasound introduced from above into the melt. Microstructure photographs show decreasing of the grain size more than five times.

  2. The effects of ultrasonic solidification on aluminum

    Directory of Open Access Journals (Sweden)

    Đorđević Slavko 1

    2003-01-01

    Full Text Available The effect of ultrasound on characteristics of solidified aluminum was shown. An ultrasonic head and ultrasonic system for modification was designed and applied to the crystallizing aluminum melt. The ultrasonic generator allows power of 50-500 W, amplitude of oscillations 10-100 um.m and the operating frequency of 25 kHz. Ultrasonic modification was done by ultrasound introduced from above into the melt. Microstructure photographs show decreasing of the grain size more than five times.

  3. Case studies in ultrasonic testing

    International Nuclear Information System (INIS)

    Prasad, V.; Satheesh, C.; Varde, P.V.

    2015-01-01

    Ultrasonic testing is widely used Non Destructive Testing (NDT) method and forms the essential part of In-service inspection programme of nuclear reactors. Main application of ultrasonic testing is for volumetric scanning of weld joints followed by thickness gauging of pipelines and pressure vessels. Research reactor Dhruva has completed the first In Service Inspection programme in which about 325 weld joints have been volumetrically scanned, in addition to thickness gauging of 300 meters of pipe lines of various sizes and about 24 nos of pressure vessels. Ultrasonic testing is also used for level measurements, distance measurements and cleaning and decontamination of tools. Two case studies are brought out in this paper in which ultrasonic testing is used successfully for identification of butterfly valve opening status and extent of choking in pipe lines in Dhruva reactor systems

  4. Internal ultrasonic inspection of flexible pipe

    Energy Technology Data Exchange (ETDEWEB)

    Baltzersen, O. (IKU Petroleumsforskning A/S, Trondheim (Norway) Norwegian Inst. of Tech., Trondheim (Norway). Div. of Petroleum Engineering and Applied Geophysics); Waag, T.I. (IKU Petroleumsforskning A/S, Trondheim (Norway))

    1993-10-01

    Methods for internal ultrasonic inspection of flexible pipe have been investigated through experiments with a short sample of Coflexip pipe. Ultrasonic backscatter methods using normal and non-normal incidence have been used for qualitative high contrast ultrasonic imaging of the inner surface of the pipe. Analysis of the internal cross-section has been performed based on the use of a non-contact ultrasonic caliper, and processing procedures which enable calculation of, and compensation for, eccentricity of the tool in the pipe. The methods developed can be used to quantitatively estimate the thickness of the internal carcass, and perform high resolution topographic mapping of the inner surface. (Author)

  5. Stresses in ultrasonically assisted bone cutting

    International Nuclear Information System (INIS)

    Alam, K; Mitrofanov, A V; Silberschmidt, V V; Baeker, M

    2009-01-01

    Bone cutting is a frequently used procedure in the orthopaedic surgery. Modern cutting techniques, such as ultrasonic assisted drilling, enable surgeons to perform precision operations in facial and spinal surgeries. Advanced understanding of the mechanics of bone cutting assisted by ultrasonic vibration is required to minimise bone fractures and to optimise the technique performance. The paper presents results of finite element simulations on ultrasonic and conventional bone cutting analysing the effects of ultrasonic vibration on cutting forces and stress distribution. The developed model is used to study the effects of cutting and vibration parameters (e.g. amplitude and frequency) on the stress distributions in the cutting region.

  6. Ultrasonic imaging of projected components of PFBR

    Energy Technology Data Exchange (ETDEWEB)

    Sylvia, J.I., E-mail: sylvia@igcar.gov.in [Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102, Tamil Nadu (India); Jeyan, M.R.; Anbucheliyan, M.; Asokane, C.; Babu, V. Rajan; Babu, B.; Rajan, K.K.; Velusamy, K.; Jayakumar, T. [Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102, Tamil Nadu (India)

    2013-05-15

    Highlights: ► Under sodium ultrasonic scanner in PFBR is for detecting protruding objects. ► Feasibility study for detecting Absorber rods and its drive mechanisms. ► Developed in-house PC based ultrasonic imaging system. ► Different case studies were carried out on simulated ARDM's. ► Implemented the experimental results to PFBR application. -- Abstract: The 500 MWe, sodium cooled, Prototype Fast Breeder Reactor (PFBR) is under advanced stage of construction at Kalpakkam in India. Opacity of sodium restricts visual inspection of components immersed in sodium by optical means. Ultrasonic wave passes through sodium hence ultrasonic techniques using under sodium ultrasonic scanners are developed to obtain under sodium images. The main objective of such an Under Sodium Ultrasonic Scanner (USUSS) for Prototype Fast Breeder Reactor (PFBR) is to detect and ensure that no core Sub Assembly (SA) or Absorber Rod or its Drive Mechanism is protruded in the above core plenum before starting the fuel handling operation. Hence, it is necessary to detect and locate the object, if it is protruding the above core plenum. To study the feasibility of detecting the absorber rods and their drive mechanisms using direct ultrasonic imaging technique, experiments were carried out for different orientations and profiles of the projected components in a 5 m diameter water tank. The in-house developed PC based ultrasonic scanning system is used for acquisition and analysis of data. The pseudo three dimensional color images obtained are discussed and the results are applicable for PFBR. This paper gives the details of the features of the absorber rods and their drive mechanisms, their orientation in the reactor core, experimental setup, PC based ultrasonic scanning system, ultrasonic images and the discussion on the results.

  7. Fundamentals of ultrasonic phased arrays

    CERN Document Server

    Schmerr, Lester W

    2014-01-01

    This book describes in detail the physical and mathematical foundations of ultrasonic phased array measurements.?The book uses linear systems theory to develop a comprehensive model of the signals and images that can be formed with phased arrays. Engineers working in the field of ultrasonic nondestructive evaluation (NDE) will find in this approach a wealth of information on how to design, optimize and interpret ultrasonic inspections with phased arrays. The fundamentals and models described in the book will also be of significant interest to other fields, including the medical ultrasound and

  8. Which hemostatic device in thyroid surgery? A network meta-analysis of surgical technologies.

    Science.gov (United States)

    Garas, George; Okabayashi, Koji; Ashrafian, Hutan; Shetty, Kunal; Palazzo, Fausto; Tolley, Neil; Darzi, Ara; Athanasiou, Thanos; Zacharakis, Emmanouil

    2013-09-01

    Energy-based hemostatic devices are increasingly being used in thyroid surgery. However, there are several limitations with regard to the existing evidence and a paucity of guidelines on the subject. The goal of this review is to employ the novel evidence synthesis technique of a network meta-analysis to assess the comparative effectiveness of surgical technologies in thyroid surgery and contribute to enhanced governance in the field of thyroid surgery. Articles published between January 2000 and June 2012 were identified from Embase, Medline, Cochrane Library, and PubMed databases. Randomized controlled trials of any size comparing the use of ultrasonic coagulation (harmonic scalpel) or Ligasure either head-to-head or against the "clamp-and-tie" technique were included. Two reviewers independently critically appraised and extracted the data from each study. The number of patients who experienced postoperative events was extracted in dichotomous format or continuous outcomes. Odds ratios were calculated by a Bayesian network meta-analysis, and metaregression was used for pair-wise comparisons. Indirect and direct comparisons were performed and inconsistency was assessed. Thirty-five randomized controlled trials with 2856 patients were included. Ultrasonic coagulation ranked first (followed by Ligasure and then clamp-and-tie) with the lowest risk of postoperative hypoparathyroidism (odds ratio 1.43 [95% confidence interval (CI) 0.77-2.67] and 0.70 [CI 0.43-1.13], ultrasonic coagulation vs. Ligasure and ultrasonic coagulation vs. clamp-and-tie, respectively), least blood loss (-0.25 [CI -0.84 to -0.35] and -1.22 [CI -1.85 to -0.59]), and drain output (0.28 [CI -0.35 to -0.91] and -0.36 [CI -0.70 to -0.03]). From a health technology viewpoint, ultrasonic coagulation was associated with the shortest operative time (-0.66 [CI -1.17 to -0.14] and -1.29 [CI -1.59 to -1.00]) and hospital stay (-0.28 [CI -0.78 to 0.22] and -0.56 [CI -1.28 to 0.15]). The only exception

  9. Aspiration of breast abscess through wide bore 14-gauge intravenous cannula.

    Science.gov (United States)

    Afridi, Shahida Parveen; Alam, Shams Nadeem; Ainuddin, Saman

    2014-10-01

    To aspirate breast abscess through a wide bore (14-gauge) intravenous (I/V) cannula and determine its efficacy in terms of the number of recurrences and number of aspirations. Case series. Dow University of Health Sciences and Civil Hospital and Bantva Hospital, Karachi, Pakistan, from January 2009 to December 2011. Patients with breast abscesses confirmed on ultrasound without skin ulceration were selected. The soft area of breast abscess with positive fluctuation was marked and fixed with index finger and thumb. A 14-gauge cannula was inserted. Pus was aspirated through a 50 cc syringe, repeated till no aspirate could be obtained. All patients were followed weekly for 4 weeks, clinically for size of lump, local tenderness and temperature, while complete resolution was confirmed on ultrasound, as resolution of the lesion. A total of 55 patients were included in this study. Mean age was 29 ± 5.58 years while ranging from 20 - 40 years. Complete resolution of abscess was seen in 31 (56.4%) cases by single aspiration. Second aspiration was required in 24 (43.6%) patients and third aspiration in single setting was required in one case only. Recurrence after the second aspiration occurred in 08 (14.5%). Incision drainage was required in 7 (12.7%) patients. Percutaneous aspiration of breast abscess through a wide bore (14-gauge) I/V cannula is a simple alternative to incision and drainage.

  10. Method and apparatus to characterize ultrasonically reflective contrast agents

    Science.gov (United States)

    Pretlow, Robert A., III (Inventor)

    1993-01-01

    A method and apparatus for characterizing the time and frequency response of an ultrasonically reflective contrast agent is disclosed. An ultrasonically reflective contrast agent is injected, under constant pressure, into a fluid flowing through a pump flow circuit. The fluid and the ultrasonically reflective contrast agent are uniformly mixed in a mixing chamber, and the uniform mixture is passed through a contrast agent chamber. The contrast agent chamber is acoustically and axially interposed between an ultrasonic transducer chamber and an acoustic isolation chamber. A pulse of ultrasonic energy is transmitted into the contrast agent chamber from the ultrasonic transducer chamber. An echo waveform is received from the ultrasonically reflective contrast agent, and it is analyzed to determine the time and frequency response of the ultrasonically reflective contrast agent.

  11. Manual Aspiration Thrombectomy with Stent Placement: Rapid and Effective Treatment for Phlegmasia Cerulea Dolens with Impending Venous Gangrene

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Ozkan, Ugur

    2008-01-01

    Phlegmasia cerulea dolens is an uncommon but potentially life-threatening complication of acute deep vein thrombosis. It is an emergency and delay in treatment may cause death or loss of the patient's limb. Surgical thrombectomy is the recommended treatment in venous gangrene. Catheter-directed intrathrombus thrombolysis has been reported as successful, but it may require a lengthy infusion. Manual aspiration thrombectomy may clear the entire thrombus with no need for thrombolytic administration and provide rapid and effective treatment for patients with phlegmasia cerulea dolens with impending venous gangrene

  12. Improvement of Ultrasonic Distance Measuring System

    Directory of Open Access Journals (Sweden)

    Jiang Yu

    2018-01-01

    Full Text Available This paper mainly introduces a kind of ultrasonic distance measuring system with AT89C51 single chip as the core component. The paper expounds the principle of ultrasonic sensor and ultrasonic ranging, hardware circuit and software program, and the results of experiment and analysis.The hardware circuit based on SCM, the software design adopts the advanced microcontroller programming language.The amplitude of the received signal and the time of ultrasonic propagation are regulated by closed loop control. [1,2]The double closed loop control technology for amplitude and time improves the measuring accuracy of the instrument. The experimental results show that greatly improves the measurement accuracy of the system.

  13. Cross-Lagged Relationships between Career Aspirations and Goal Orientation in Early Adolescents

    Science.gov (United States)

    Creed, Peter; Tilbury, Clare; Buys, Nick; Crawford, Meegan

    2011-01-01

    We surveyed 217 students (145 girls; average age = 14.6 years) on two occasions, twelve months apart, on measures of career aspirations (job aspirations, job expectations, educational aspirations) and goal orientation (learning, performance-prove, performance-avoid), and tested the causal relationship between goal orientation and aspirations. We…

  14. Does aspiration of bones and joints affect results of later bone scanning

    International Nuclear Information System (INIS)

    Canale, S.T.; Harkness, R.M.; Thomas, P.A.; Massie, J.D.

    1985-01-01

    To determine the effect, if any, of needle aspiration on /sup 99m/Tc bone scanning, three different areas of 15 dogs were first aspirated and then imaged with technetium bone scintigraphy. The hip joint was aspirated, the distal femoral metaphysis was drilled and aspirated, and the tibial periosteum was scraped with an 18- or 20-gauge needle. Varying amounts of trauma were inflicted to simulate varying difficulties at aspiration. /sup 99m/Tc bone scans were obtained from 5 h to 10 days later. There was no evidence of focal technetium uptake after any hip joint aspiration. This was consistent regardless of the amount of trauma inflicted or the time from aspiration to bone scanning. Metaphyseal cortical drilling and tibial periosteal scraping occasionally caused some focal uptake when scanning was delayed greater than 2 days. When osteomyelitis or pyarthrosis is clinically suspected, joint aspiration can be performed without fear of producing a false- positive bone scan

  15. Ultrasonic tests on materials with protective coatings

    International Nuclear Information System (INIS)

    Whaley, H.L.

    1977-01-01

    Protective coatings are applied to some nuclear components such as reactor vessels to inhibit surface corrosion. Since in-service ultrasonic inspection is required for such components, a study was performed to determine whether the use of protective coatings can affect ultrasonic tests. Two 2 in. thick steel plates were uniformly machined, sandblasted, and used as bases for two types of protective coatings. The type and thickness of the coating and the presence of contamination, such as fingerprints or mild oxidation under the paint, were the independent variables associated with the coating. Tests were run to determine the effects of the protective coatings on ultrasonic tests conducted on the steel plates. Significant variations in ultrasonic test sensitivity occurred as a function of the type and thickness of protective coating, couplant (material that conducts the ultrasound from the transducer into the test part, normally water or some type of oil), transducer wear plate, and ultrasonic test frequency. Ultrasonic tests can be strongly affected by a protective coating on the component to be inspected. As compared to the test sensitivity for an uncoated reference sample, the sensitivity may be dramatically shifted up or down on the coated surface. In certain coating thickness ranges, the sensitivity can fluctuate widely with small changes in coating thickness. If a coating is chosen properly, however, components with protective coatings can be tested ultrasonically with valid results. These results are for the case of ultrasonic input on the coated surface. It is not expected that an ultrasonic test conducted from the front surface would be appreciably affected by a coating on the rear surface

  16. Aspiration lung disorders in bovines: a case report and review.

    Science.gov (United States)

    Shakespeare, Anthony S

    2012-11-01

    Lung aspiration disorders in bovines are invariably diagnosed as infectious aspiration pneumonias. There is a distinct differentiation between aspiration pneumonia and aspiration pneumonitis in humans that can be applied to bovines. The nature and quantity of the aspirate can result in differing pathogeneses which can require differing therapeutic approaches. Whilst blood gases were important in detecting and prognosticating lung problems, changes in barometric pressure with altitude have to be considered when interpreting partial pressures of oxygen. Anatomical differences in the lungs of bovines can explain why this species is more prone to certain pneumonic problems. Pulmonary physiotherapy is important in treating lung disorders in humans and should be considered as an adjunct therapy in bovine respiratory conditions. A case work-up was used to highlight some of the points discussed in this article.

  17. Measurement of membrane elasticity by micro-pipette aspiration

    DEFF Research Database (Denmark)

    Henriksen, Jonas Rosager; Ipsen, John H.

    2004-01-01

    The classical micro-pipette aspiration technique, applied for measuring the membrane bending elasticity, is in the present work reviewed and extended to span the range of pipette aspiration pressures going through the °accid (low pressures) to tense (high pressures) membrane regime. The quality...

  18. Ultrasonic propulsion of kidney stones.

    Science.gov (United States)

    May, Philip C; Bailey, Michael R; Harper, Jonathan D

    2016-05-01

    Ultrasonic propulsion is a novel technique that uses short bursts of focused ultrasonic pulses to reposition stones transcutaneously within the renal collecting system and ureter. The purpose of this review is to discuss the initial testing of effectiveness and safety, directions for refinement of technique and technology, and opinions on clinical application. Preclinical studies with a range of probes, interfaces, and outputs have demonstrated feasibility and consistent safety of ultrasonic propulsion with room for increased outputs and refinement toward specific applications. Ultrasonic propulsion was used painlessly and without adverse events to reposition stones in 14 of 15 human study participants without restrictions on patient size, stone size, or stone location. The initial feasibility study showed applicability in a range of clinically relevant situations, including facilitating passage of residual fragments following ureteroscopy or shock wave lithotripsy, moving a large stone at the ureteropelvic junction with relief of pain, and differentiating large stones from a collection of small fragments. Ultrasonic propulsion shows promise as an office-based system for transcutaneously repositioning kidney stones. Potential applications include facilitating expulsion of residual fragments following ureteroscopy or shock wave lithotripsy, repositioning stones prior to treatment, and repositioning obstructing ureteropelvic junction stones into the kidney to alleviate acute renal colic.

  19. [The diagnostic value of ultrasonic elastography and ultrasonography comprehensive score in cervical lesions].

    Science.gov (United States)

    Lu, R; Xiao, Y

    2017-07-18

    Objective: To evaluate the clinical value of ultrasonic elastography and ultrasonography comprehensive scoring method in the diagnosis of cervical lesions. Methods: A total of 116 patients were selected from the Department of Gynecology of the first hospital affiliated with Central South University from March 2014 to September 2015.All of the lesions were preoperatively examined by Doppler Ultrasound and elastography.The elasticity score was determined by a 5-point scoring method. Calculation of the strain ratio was based on a comparison of the average strain measured in the lesion with the adjacent tissue of the same depth, size, and shape.All these ultrasonic parameters were quantified, added, and arrived at ultrasonography comprehensive scores.To use surgical pathology as the gold standard, the sensitivity, specificity, accuracy of Doppler Ultrasound, elasticity score and strain ratio methods and ultrasonography comprehensive scoring method were comparatively analyzed. Results: (1) The sensitivity, specificity, and accuracy of Doppler Ultrasound in diagnosing cervical lesions were 82.89% (63/76), 85.0% (34/40), and 83.62% (97/116), respectively.(2) The sensitivity, specificity, and accuracy of the elasticity score method were 77.63% (59/76), 82.5% (33/40), and 79.31% (92/116), respectively; the sensitivity, specificity, and accuracy of the strain ratio measure method were 84.21% (64/76), 87.5% (35/40), and 85.34% (99/116), respectively.(3) The sensitivity, specificity, and accuracy of ultrasonography comprehensive scoring method were 90.79% (69/76), 92.5% (37/40), and 91.38% (106/116), respectively. Conclusion: (1) It was obvious that ultrasonic elastography had certain diagnostic value in cervical lesions. Strain ratio measurement can be more objective than elasticity score method.(2) The combined application of ultrasonography comprehensive scoring method, ultrasonic elastography and conventional sonography was more accurate than single parameter.

  20. Aspiration of Breast Abscess through Wide Bore 14-Gauge Intravenous Cannula

    International Nuclear Information System (INIS)

    Afridi, S. P.; Alam, S. N.; Ainuddin, S.

    2014-01-01

    Objective: To aspirate breast abscess through a wide bore (14-gauge) intravenous (I/V) cannula and determine its efficacy in terms of the number of recurrences and number of aspirations. Study Design: Case series. Place and Duration of Study: Dow University of Health Sciences and Civil Hospital and Bantva Hospital, Karachi, Pakistan, from January 2009 to December 2011. Methodology: Patients with breast abscesses confirmed on ultrasound without skin ulceration were selected. The soft area of breast abscess with positive fluctuation was marked and fixed with index finger and thumb. A 14-gauge cannula was inserted. Pus was aspirated through a 50 cc syringe, repeated till no aspirate could be obtained. All patients were followed weekly for 4 weeks, clinically for size of lump, local tenderness and temperature, while complete resolution was confirmed on ultrasound, as resolution of the lesion. Results: A total of 55 patients were included in this study. Mean age was 29 +- 5.58 years while ranging from 20 - 40 years. Complete resolution of abscess was seen in 31 (56.4%) cases by single aspiration. Second aspiration was required in 24 (43.6%) patients and third aspiration in single setting was required in one case only. Recurrence after the second aspiration occurred in 08 (14.5%). Incision drainage was required in 7 (12.7%) patients. Conclusion: Percutaneous aspiration of breast abscess through a wide bore (14-gauge) I/V cannula is a simple alternative to incision and drainage. (author)

  1. Fine-needle aspiration cytology in children with superficial lymphadenopathy

    Directory of Open Access Journals (Sweden)

    F. De Corti

    2014-04-01

    Full Text Available Introduction: In pediatric population Fine-Needle Aspiration Citology (FNAC is slowly gaining acceptance in clinical management of Superficial Lymphadenopathy (SL. Our experience adds some data about the usefulness of this technique in diagnosing the cause of a SL and therefore guiding further treatment. Patients and Methods: 238 FNAC were performed in 217 patients with SL, observed at our Institution from 2002 to 2006. The neck was the most frequent localization. The results were available within few hours. In cases of granulomatous findings, the samples were processed for microbiological and PCR test, in order to identify Mycobacteria. Results: 174 were reactive lesions, 38 granulomatous lymphadenopathies, 24 malignant lesions, 2 specimens inadequate for diagnosis. Among the 174 reactive SL, 22 required an incisional biopsy after 1 month follow-up. Among the granulomatous lymphadenopathies, 13 children with Cat-Scratch Disease recovered, 25 with Mycobacteria infection underwent surgical excision. For 24 malignant lesions, the diagnosis was confirmed by further biopsy. Two false negative and no false positive were detected (sensitivity 92%, specificity 100%. No complications were encountered. Conclusions: In our experience FNAC, performed by experienced cytopathologist, has revealed to be a fast, safe, non invasive and inexpensive method to achieve diagnosis in persistent SL. The use of FNAC gave us the possibility to select patients for further investigation and/or surgical treatment. Incisional biopsy remains necessary to confirm the diagnosis in case of malignancy or doubtful lesions.

  2. Study on electrical impedance matching for broadband ultrasonic transducer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Geon Woo [University of Science and Technology, Daejeon (Korea, Republic of); Kim, Ki Bok [Korea Research Institute of Standards and Science, Center for Safety Measurement, Daejeon (Korea, Republic of); Baek, Kwang Sae [Elache Co., Busan (Korea, Republic of)

    2017-02-15

    Ultrasonic transducers with high resolution and resonant frequency are required to detect small defects (less than hundreds of μm) by ultrasonic testing. The resonance frequency and resolution of an ultrasonic transducer are closely related to the thickness of piezo-electric materials, backing materials, and the electric impedance matching technique. Among these factors, electrical impedance matching plays an important role because it can reduce the loss and reflection of ultrasonic energy differences in electrical impedance between an ultrasonic transducer and an ultrasonic defects detecting system. An LC matching circuit is the most frequently used electric matching method. It is necessary for the electrical impedance of an ultrasonic transducer to correspond to approximately 50 Ω to compensate the difference in electrical impedance between both connections. In this study, a 15 MHz immersion ultrasonic transducer was fabricated and an LC electrical impedance circuit was applied to that for having broad-band frequency characteristic.

  3. Aspiration af dentalt fremmedlegeme under tandlaegebesøg

    DEFF Research Database (Denmark)

    Omland, Silje Haukali; Lindegaard, Peter; Omland, Øyvind

    2009-01-01

    We present a case of foreign body aspiration, the diagnosis of which was delayed until one and a half month after the event. Usually foreign body aspiration leads to acute symptoms, but these may be absent, especially in elderly patients, which delays and complicates diagnosis. Late complications...

  4. Discordance Rate between Thyroid Fine Needle Aspiration Cytology ...

    African Journals Online (AJOL)

    Discordance Rate between Thyroid Fine Needle Aspiration Cytology and Histopathologic Diagnosis. Wondwossen Ergete, Daniel Abebe. Abstract. Fine Needle Aspiration (FNA) of the thyroid is a low cost procedure, which can give an accurate diagnosis promptly. The objective of this study was to assess the diagnostic ...

  5. Ultrasonic inspection of austenitic welds

    International Nuclear Information System (INIS)

    Baikie, B.L.; Wagg, A.R.; Whittle, M.J.; Yapp, D.

    1976-01-01

    Optical and X-ray metallography combined with ultrasonic testing by compression waves was used for inspection of stainless steel weld metal produced by three different welding techniques. X-ray diffraction showed that each weld possessed a characteristic fibre textured structure which was shown by optical microscopy to be parallel to columnar grain boundaries. Metallographic evidence suggested that the development of fibre texture is due to the mechanism of competitive growth. From observations made as a result of optical metallographic examination the orientation of the fibre axis could be predicted if the weld geometry and welding procedure were known. Ultrasonic velocity and attenuation measurements as a continuous function of grain orientation, made on cylinders machined from weld samples, showed that attenuation was strongly orientation dependent. It was concluded that the sensitivity of ultrasonic inspection to small defects is unlikely to be as high for austenitic welds as for ferritic even when transmission is improved by modifying the welding procedure to improve the ultrasonic transmission. (U.K.)

  6. Rail inspection using noncontact laser ultrasonics

    International Nuclear Information System (INIS)

    Kim, Nak Hyeon; Sohn, Hoon; Han, Soon Woo

    2012-01-01

    In this study, a noncontact laser ultrasonic system is proposed for rail defect detection. An Nd Yag pulse laser is used for generation of ultrasonic waves, and the corresponding ultrasonic responses are measured by a laser Doppler vibrometer. For the detection of rail surface damages, the shape of the excitation laser beam is transformed into a line. On the other hand, a point source laser beam is used for the inspection of defects inside a rail head. Then, the interactions of propagating ultrasonic waves with defects are examined using actual rail specimens. Amplitude attenuation was mainly observed for a surface crack, and reflections were most noticeable from an internal damage. Finally, opportunities and challenges associated with real time rail inspection from a high speed train are discussed

  7. Aspiration lung disorders in bovines: A case report and review

    Directory of Open Access Journals (Sweden)

    Anthony S. Shakespeare

    2012-04-01

    Full Text Available Lung aspiration disorders in bovines are invariably diagnosed as infectious aspiration pneumonias. There is a distinct differentiation between aspiration pneumonia and aspiration pneumonitis in humans that can be applied to bovines. The nature and quantity of the aspirate can result in differing pathogeneses which can require differing therapeutic approaches. Whilst blood gases were important in detecting and prognosticating lung problems, changes in barometric pressure with altitude have to be considered when interpreting partial pressures of oxygen. Anatomical differences in the lungs of bovines can explain why this species is more prone to certain pneumonic problems. Pulmonary physiotherapy is important in treating lung disorders in humans and should be considered as an adjunct therapy in bovine respiratory conditions. A case work-up was used to highlight some of the points discussed in this article.

  8. Aspiration lung disorders in bovines: A case report and review

    Directory of Open Access Journals (Sweden)

    Anthony S. Shakespeare

    2012-11-01

    Full Text Available Lung aspiration disorders in bovines are invariably diagnosed as infectious aspiration pneumonias. There is a distinct differentiation between aspiration pneumonia and aspiration pneumonitis in humans that can be applied to bovines. The nature and quantity of the aspirate can result in differing pathogeneses which can require differing therapeutic approaches. Whilst blood gases were important in detecting and prognosticating lung problems, changes in barometric pressure with altitude have to be considered when interpreting partial pressures of oxygen. Anatomical differences in the lungs of bovines can explain why this species is more prone to certain pneumonic problems. Pulmonary physiotherapy is important in treating lung disorders in humans and should be considered as an adjunct therapy in bovine respiratory conditions. A case work-up was used to highlight some of the points discussed in this article.

  9. Comparison of cough reflex test against instrumental assessment of aspiration.

    Science.gov (United States)

    Miles, Anna; Moore, Sara; McFarlane, Mary; Lee, Fiona; Allen, Jacqueline; Huckabee, Maggie-Lee

    2013-06-13

    Silent aspiration is associated with pneumonia and mortality, and is poorly identified by traditional clinical swallowing evaluation (CSE). The aim of this study was to validate cough reflex testing (CRT) for identification of silent aspiration against aspiration confirmed by instrumental assessment. Cough reflex threshold testing was completed on all patients using inhaled, nebulised citric acid. Within an hour, 80 patients underwent videofluoroscopic study of swallowing (VFSS) and 101 patients underwent fibreoptic endoscopic evaluation of swallowing (FEES). All tests were recorded and analysed by two researchers blinded to the result of the alternate test. Significant associations between CRT result and cough response to aspiration on VFSS (X(2) (2)=11.046, p=.003) and FEES (X(2) (2)=34.079, pacid provide a better predictive measure of silent aspiration. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Ultrasonic characterization of yogurt fermentation process

    OpenAIRE

    IZBAIM , DRIS; FAIZ , BOUAZZA; MOUDDEN , ALI; MALAININE , MOHAMED; ABOUDAOUD , Idriss

    2012-01-01

    International audience; The objective of this work is to characterize the fermentation of yogurt based on an ultrasonic technique. Conventionally, the acidity of the yogurt is measured by a pH meter to determine the progress of fermentation. However, the pH meter should be cleaned and calibrated for each measurement and, therefore, this method is not practical. In this regard, ultrasonic techniques are fast, non-invasive and inexpensive. The measurement of ultrasonic parameters such as amplit...

  11. Ultrasonic Characterization of Superhard Material: Osmium Diboride

    International Nuclear Information System (INIS)

    Yadawa, P K

    2012-01-01

    Higher order elastic constants have been calculated in hexagonal structured superhard material OsB 2 at room temperature following the interaction potential model. The temperature variation of the ultrasonic velocities is evaluated along different angles with unique axis of the crystal using the second order elastic constants. The ultrasonic velocity decreases with the temperature along particular orientation with the unique axis. Temperature variation of the thermal relaxation time and Debye average velocities are also calculated along the same orientation. The temperature dependency of the ultrasonic properties is discussed in correlation with elastic, thermal and electrical properties. It has been found that the thermal conductivity is the main contributor to the behaviour of ultrasonic attenuation as a function of temperature and the responsible cause of attenuation is phonon-phonon interaction. The mechanical properties of OsB 2 at low temperature are better than at high temperature, because at low temperature it has low ultrasonic velocity and ultrasonic attenuation. Superhard material OsB 2 has many industrial applications, such as abrasives, cutting tools and hard coatings.

  12. Studies on Section XI ultrasonic repeatability

    International Nuclear Information System (INIS)

    Jamison, T.D.; McDearman, W.R.

    1981-05-01

    A block representative of a nuclear component has been welded containing intentional defects. Acoustic emission data taken during the welding correlate well with ultrasonic data. Repetitive ultrasonic examinations have been performed by skilled operators using a procedure based on that desribed in ASME Section XI. These examinations were performed by different examination teams using different ultrasonic equipment in such a manner that the effects on the repeatability of the ultrasonic test method caused by the operator and by the use of different equipment could be estimated. It was tentatively concluded that when considering a large number of inspections: (1) there is no significant difference in indication sizing between operators, and (2) there is a significant difference in amplitude and defect sizing when instruments having different, Code acceptable operating characteristics are used. It was determined that the Section XI sizing parameters follow a bivariate normal distribution. Data derived from ultrasonically and physically sizing indications in nuclear components during farication show that the Section XI technique tends to overestimate the size of the reflectors

  13. Uncertainty estimation of ultrasonic thickness measurement

    International Nuclear Information System (INIS)

    Yassir Yassen, Abdul Razak Daud; Mohammad Pauzi Ismail; Abdul Aziz Jemain

    2009-01-01

    The most important factor that should be taken into consideration when selecting ultrasonic thickness measurement technique is its reliability. Only when the uncertainty of a measurement results is known, it may be judged if the result is adequate for intended purpose. The objective of this study is to model the ultrasonic thickness measurement function, to identify the most contributing input uncertainty components, and to estimate the uncertainty of the ultrasonic thickness measurement results. We assumed that there are five error sources significantly contribute to the final error, these sources are calibration velocity, transit time, zero offset, measurement repeatability and resolution, by applying the propagation of uncertainty law to the model function, a combined uncertainty of the ultrasonic thickness measurement was obtained. In this study the modeling function of ultrasonic thickness measurement was derived. By using this model the estimation of the uncertainty of the final output result was found to be reliable. It was also found that the most contributing input uncertainty components are calibration velocity, transit time linearity and zero offset. (author)

  14. Image-guided fine needle cytology with aspiration versus non-aspiration in retroperitoneal masses: is aspiration necessary?

    Science.gov (United States)

    Misra, Rajiv Kumar; Mitra, Shaila; Jain, Rishav Kumar; Vahikar, Shilpa; Bundela, Archana; Misra, Purak

    2015-03-01

    Although using fine needle cytology with aspiration (FNC-A) for establishing diagnoses in the retroperitoneal region has shown promise, there is scant literature supporting a role of non-aspiration cytology (FNC-NA) for this region. We assessed the accuracy and reliability of FNC-A and FNC-NA as tools for preoperative diagnosis of retroperitoneal masses and compared the results of both techniques with each other and with histopathology. Fifty-seven patients with retroperitoneal masses were subjected to FNC-A and FNC-NA. Smears were stained with May-Grunwald Giemsa and hematoxylin and eosin stain. An individual slide was objectively analysed using a point scoring system to enable comparison between FNC-A and FNC-NA. By FNC-A, 91.7% accuracy was obtained in cases of retroperitoneal lymph node lesions followed by renal masses (83.3%). The diagnostic accuracy of other sites by FNC-A varied from 75.0%-81.9%. By FNC-NA, 93.4% diagnostically accurate results were obtained in the kidney, followed by 75.0% in adrenal masses. The diagnostic accuracy of other sites by FNC-NA varied from 66.7%-72.8%. Although both techniques have their own advantages and disadvantages, FNC-NA may be a more efficient adjuvant method of sampling in retroperitoneal lesions.

  15. Experimental investigation of ultrasonic velocity anisotropy in ...

    Indian Academy of Sciences (India)

    Permanent link: https://www.ias.ac.in/article/fulltext/pram/077/02/0345-0355. Keywords. Magnetic fluids; ultrasonic wave; sound velocity; anisotropy. Abstract. Magnetic field-induced dispersion of ultrasonic velocity in a Mn0.7Zn0.3Fe2O4 fluid (applied magnetic field is perpendicular to the ultrasonic propagation vector) is ...

  16. Ultrasonic Waveguide Sensor with a Layer-Structured Plate

    International Nuclear Information System (INIS)

    Joo, Young Sang; Bae, Jin Ho; Kim, Jong Bum

    2010-01-01

    In-vessel structures of a sodium-cooled fast reactor (SFR) are submerged in opaque liquid sodium in reactor vessel. The ultrasonic inspection techniques should be applied for observing the in-vessel structures under hot liquid sodium. Ultrasonic sensors such as immersion sensors and rod-type waveguide sensors had developed in order to apply under-sodium viewing of the in-vessel structures of SFR. Recently the novel plate-type ultrasonic waveguide sensor has been developed for the versatile application of under-sodium viewing in SFR. In the previous studies, the Ultrasonic waveguide sensor module had been designed and manufactured. And the feasibility study of the ultrasonic waveguide sensor has been performed. To Improve the performance of the ultrasonic waveguide sensor module in the under-sodium application, the dispersion effect due to the 10 m long distance propagation of the A 0 -mode Lamb wave should be minimized and the longitudinal leaky wave in a liquid sodium should be generated within the range of the effective radiation angle. In this study, a new concept of ultrasonic waveguide sensor with a layered-structured plate is suggested for the non-dispersive propagation of A 0 -mode Lamb wave in an ultrasonic waveguide sensor and the effective generation of leaky wave in a liquid sodium

  17. 21 CFR 882.1925 - Ultrasonic scanner calibration test block.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic scanner calibration test block. 882... Ultrasonic scanner calibration test block. (a) Identification. An ultrasonic scanner calibration test block is a block of material with known properties used to calibrate ultrasonic scanning devices (e.g., the...

  18. Ultrasonic attenuation in superconducting zinc

    International Nuclear Information System (INIS)

    Auluck, S.

    1978-01-01

    The differences in the Zn ultrasonic attenuation data of different workers are analyzed. The superconducting energy gaps deduced from our analysis of the ultrasonic-attenuation data of Cleavelin and Marshall are consistent with the gaps deduced from the knowledge of the Fermi surface and the electron-phonon mass enhancement factor

  19. European Thyroid Association Guidelines regarding Thyroid Nodule Molecular Fine-Needle Aspiration Cytology Diagnostics.

    Science.gov (United States)

    Paschke, Ralf; Cantara, Silvia; Crescenzi, Anna; Jarzab, Barbara; Musholt, Thomas J; Sobrinho Simoes, Manuel

    2017-07-01

    Molecular fine-needle aspiration (FNA) cytology diagnostics has the potential to address the inherent limitation of FNA cytology which is an indeterminate (atypia of undetermined significance/follicular lesion of undetermined significance follicular neoplasm) cytology. Because of the emerging role of molecular FNA cytology diagnostics, the European Thyroid Association convened a panel of international experts to review methodological aspects, indications, results, and limitations of molecular FNA cytology diagnostics. The panel reviewed the evidence for the diagnostic value of mutation panel assessment (including at least BRAF , NRAS , HRAS , KRAS , PAX8/PPARG , RET/PTC ) of targeted next generation sequencing and of a microarray gene expression classifier (GEC) test in the diagnostic assessment of an indeterminate cytology thyroid nodule. Moreover, possible surgical consequences of molecular FNA diagnostic results of thyroid nodules and the evidence that analysis of a molecular FNA diagnostic panel of somatic mutations or a microarray GEC test can alter the follow-up were reviewed. Molecular tests may help clinicians to drive patient care and the surgical decision if the analysis is performed in specialized laboratories. These molecular tests require standardization of performance characteristics and appropriate calibration as well as analytic validation before clinical interpretation.

  20. Rural Aspirations, Rural Futures: From "Problem" to Possibility

    Science.gov (United States)

    Tieken, Mara Casey; San Antonio, Donna M.

    2016-01-01

    Young people aspire, make choices, and develop within a particular place and historical context. Recently, federal and state governments, policy and research institutes, and advocacy organizations have shown a growing interest in the aspirations and transitions of rural youth--and, in particular, the role that schools play in shaping and…

  1. Aspiration Pneumonia in Acute Stroke | SALAMI | Sahel Medical ...

    African Journals Online (AJOL)

    Abstract. This was a prospective study that was conducted between July 2000 and September 2001. It was designed to determine the incidence and the risk factor(s) of aspiration pneumonia in patients with acute cerebrovascular accident. Aspiration pneumonia was recorded in 23.5% of the 68 patients that were recruited.

  2. Ultrasonic scanner for stainless steel weld inspections. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Kupperman, D. S.; Reimann, K. J.

    1978-09-01

    The large grain size and anisotropic nature of stainless steel weld metal make conventional ultrasonic testing very difficult. A technique is evaluated for minimizing the coherent ultrasonic noise in stainless steel weld metal. The method involves digitizing conventional ''A-scan'' traces and averaging them with a minicomputer. Results are presented for an ultrasonic scanner which interrogates a small volume of the weld metal while averaging the coherent ultrasonic noise.

  3. Gender contentedness in aspirations to become engineers or medical doctors

    Science.gov (United States)

    Koul, Ravinder; Lerdpornkulrat, Thanita; Poondej, Chanut

    2017-11-01

    Medical doctor and engineer are highly esteemed STEM professions. This study investigates academic and motivational characteristics of a sample of high school students in Thailand who aspire to become medical doctors or engineers. We used logistic regression to compare maths performance, gender typicality, gender contentedness, and maths and physics self-concepts among students with aspirations for these two professions. We found that high levels of felt gender contentedness in men had positive association with aspirations for engineering irrespective of the levels of maths or physics self-concept. We found that high levels of felt gender contentedness combined with high levels of maths or physics self-concept in women had positive associations with aspirations to become a medical doctor. These findings are evidence that student views of self are associated with uneven gendered patterns in career aspirations and have implications for the potential for future participation.

  4. Ultrasonic assisted hot metal powder compaction.

    Science.gov (United States)

    Abedini, Rezvan; Abdullah, Amir; Alizadeh, Yunes

    2017-09-01

    Hot pressing of metal powders is used in production of parts with similar properties to wrought materials. During hot pressing processes, particle rearrangement, plastic deformation, creep, and diffusion are of the most effective powder densification mechanisms. Applying ultrasonic vibration is thought to result in great rates of densification and therefore higher efficiency of the process is expected. This paper deals with the effects of power ultrasonic on the densification of AA1100 aluminum powder under constant applied stress. The effects of particle size and process temperature on the densification behavior are discussed. The results show that applying ultrasonic vibration leads to an improved homogeneity and a higher relative density. Also, it is found that the effect of ultrasonic vibration is greater for finer particles. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Ultrasonic nondestructive materials characterization

    Science.gov (United States)

    Green, R. E., Jr.

    1986-01-01

    A brief review of ultrasonic wave propagation in solid materials is presented with consideration of the altered behavior in anisotropic and nonlinear elastic materials in comparison with isotropic and linear elastic materials. Some experimental results are described in which ultrasonic velocity and attenuation measurements give insight into materials microstructure and associated mechanical properties. Recent developments with laser beam non-contact generation and detection of ultrasound are presented. The results of several years of experimental measurements using high-power ultrasound are discussed, which provide substantial evidence of the inability of presently accepted theories to fully explain the interaction of ultrasound with solid materials. Finally, a special synchrotron X-ray topographic system is described which affords the possibility of observing direct interaction of ultrasonic waves with the microstructural features of real crystalline solid materials for the first time.

  6. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  7. Study on Effect of Ultrasonic Vibration on Grinding Force and Surface Quality in Ultrasonic Assisted Micro End Grinding of Silica Glass

    Directory of Open Access Journals (Sweden)

    Zhang Jianhua

    2014-01-01

    Full Text Available Ultrasonic vibration assisted micro end grinding (UAMEG is a promising processing method for micro parts made of hard and brittle materials. First, the influence of ultrasonic assistance on the mechanism of this processing technology is theoretically analyzed. Then, in order to reveal the effects of ultrasonic vibration and grinding parameters on grinding forces and surface quality, contrast grinding tests of silica glass with and without ultrasonic assistance using micro radial electroplated diamond wheel are conducted. The grinding forces are measured using a three-component dynamometer. The surface characteristics are detected using the scanning electron microscope. The experiment results demonstrate that grinding forces are significantly reduced by introducing ultrasonic vibration into conventional micro end grinding (CMEG of silica glass; ultrasonic assistance causes inhibiting effect on variation percentages of tangential grinding force with grinding parameters; ductile machining is easier to be achieved and surface quality is obviously improved due to ultrasonic assistance in UAMEG. Therefore, larger grinding depth and feed rate adopted in UAMEG can lead to the improvement of removal rate and machining efficiency compared with CMEG.

  8. Gender, aspirations, and achievements : Relating work and family aspirations to occupational outcomes

    NARCIS (Netherlands)

    van der Horst, Mariska

    2014-01-01

    Although women have increased their labour market participation and educational level they still lag behind men in their occupational achievements. An important discussion in the literature as well as in popular media is whether this is due to a gender difference in aspirations. In this study the

  9. Lumber defect detection by ultrasonics

    Science.gov (United States)

    K. A. McDonald

    1978-01-01

    Ultrasonics, the technology of high-frequency sound, has been developed as a viable means for locating most defects In lumber for use in digital form in decision-making computers. Ultrasonics has the potential for locating surface and internal defects in lumber of all species, green or dry, and rough sawn or surfaced.

  10. Evaluation of the natural history of patients who aspirate.

    Science.gov (United States)

    Bock, Jonathan M; Varadarajan, Varun; Brawley, Mary C; Blumin, Joel H

    2017-12-01

    The natural clinical progression of aspiration to eventual pulmonary compromise is not well understood. We hypothesized that dietary modification recommendations, Penetration-Aspiration Scale (PAS) score, and dysphagia etiology would be associated with changes in time to first pulmonary event and overall survival for patients with documented aspiration on radiologic testing. This study identified a cohort of patients with detectable unsensed penetration or aspiration on videofluoroscopic swallowing study (VFSS), and followed this cohort over time for development of pulmonary events and death. We then evaluated the association of aspiration severity and dietary modification recommendations on incidence of these endpoints. Retrospective chart review. A total of 2,616 VFSS exam reports were reviewed from our institution performed between January 1, 2009 and December 31, 2010. Aspiration or unsensed penetration (PAS of 5 or greater) was detected in 564 (21.5%) of these patients, who were then included in the study cohort. Medical records were reviewed retrospectively for development of pulmonary events (pneumonia, pneumonitis, or other life-threatening pulmonary illness) and all-cause mortality for up to 54 months after initial VFSS. Univariate Kaplan-Meier analysis and multivariate Cox regression were performed for time to first pulmonary event and survival predicted by recommended diet, PAS score, and dysphagia etiology. Dysphagia etiology was highly associated with increased development of pulmonary events for some patients, especially those with generalized nonspecific dysphagia due to deconditioning or frailty (hazard ratio [HZ] vs. stroke 2.95, 95% confidence interval [CI]: 1.53-5.69, P = .001) and esophageal dysphagia (HZ: 2.66, 95% CI: 1.17-6.02, P = .019). Dysphagia etiology was also associated with increased mortality for patients with generalized nonspecific dysphagia due to deconditioning or frailty (HZ: 3.32, 95% CI: 2.0-5.52, P dysphagia is associated

  11. Computer simulation of ultrasonic testing for aerospace vehicle

    Energy Technology Data Exchange (ETDEWEB)

    Yamawaki, H [National Institute for Materials Science, 1-2-1, Sengen, 305-0047 Tsukuba (Japan); Moriya, S; Masuoka, T [Japan Aerospace Exploration Agency, 1 Koganesawa, Kimigawa, 981-1525 Kakuda (Japan); Takatsubo, J, E-mail: yamawaki.hisashi@nims.go.jp [Advanced Industrial Science and Technology, AIST Tsukuba Central 2, 1-1-1 Umezono, 305-8568 Tsukuba (Japan)

    2011-01-01

    Non-destructive testing techniques are developed to secure reliability of aerospace vehicles used repetitively. In the case of cracks caused by thermal stress on walls in combustion chambers of liquid-fuel rockets, it is examined by ultrasonic waves visualization technique developed in AIST. The technique is composed with non-contact ultrasonic generation by pulsed-laser scanning, piezoelectric transducer for the ultrasonic detection, and image reconstruction processing. It enables detection of defects by visualization of ultrasonic waves scattered by the defects. In NIMS, the condition of the detection by the visualization is investigated using computer simulation for ultrasonic propagation that has capability of fast 3-D calculation. The simulation technique is based on finite-difference method and two-step elastic wave equations. It is reported about the investigation by the calculation, and shows availability of the simulation for the ultrasonic testing technique of the wall cracks.

  12. Fundamentals and applications of ultrasonic waves

    CERN Document Server

    Cheeke, J David N

    2002-01-01

    Ultrasonics. A subject with applications across all the basic sciences, engineering, medicine, and oceanography, yet even the broader topic of acoustics is now rarely offered at undergraduate levels. Ultrasonics is addressed primarily at the doctoral level, and texts appropriate for beginning graduate students or newcomers to the field are virtually nonexistent.Fundamentals and Applications of Ultrasonic Waves fills that void. Designed specifically for senior undergraduates, beginning graduate students, and those just entering the field, it begins with the fundamentals, but goes well beyond th

  13. Ultrasonic flow measurements for irrigation process monitoring

    Science.gov (United States)

    Ziani, Elmostafa; Bennouna, Mustapha; Boissier, Raymond

    2004-02-01

    This paper presents the state of the art of the general principle of liquid flow measurements by ultrasonic method, and problems of flow measurements. We present an ultrasonic flowmeter designed according to smart sensors concept, for the measurement of irrigation water flowing through pipelines or open channels, using the ultrasonic transit time approach. The new flowmeter works on the principle of measuring time delay differences between sound pulses transmitted upstream and downstream in the flowing liquid. The speed of sound in the flowing medium is eliminated as a variable because the flowrate calculations are based on the reciprocals of the transmission times. The transit time difference is digitally measured by means of a suitable, microprocessor controlled logic. This type of ultrasonic flowmeter will be widely used in industry and water management, it is well studied in this work, followed by some experimental results. For pressurized channels, we use one pair of ultrasonic transducer arranged in proper positions and directions of the pipe, in this case, to determine the liquid velocity, a real time on-line analysis taking account the geometries of the hydraulic system, is applied to the obtained ultrasonic data. In the open channels, we use a single or two pairs of ultrasonic emitter-receiver according to the desired performances. Finally, the goals of this work consist in integrating the smart sensor into irrigation systems monitoring in order to evaluate potential advantages and demonstrate their performance, on the other hand, to understand and use ultrasonic approach for determining flow characteristics and improving flow measurements by reducing errors caused by disturbances of the flow profiles.

  14. Aspirations and occupational achievements of Dutch fathers and mothers

    NARCIS (Netherlands)

    van der Horst, Mariska; van der Lippe, Tanja; Kluwer, Esther

    2014-01-01

    Purpose - To investigate how work and family aspirations relate to occupational achievements and gender differences herein. Design/methodology/approach - Using data from 2009 we examined the relationship between career and childrearing aspirations and occupational achievements of Dutch parents.

  15. Gender and leadership aspiration: the impact of organizational identification

    NARCIS (Netherlands)

    Fritz, C. (Claudia); D.L. van Knippenberg (Daan)

    2017-01-01

    textabstractPurpose: Although nowadays more women occupy leadership roles, they still are a minority. Because aspiration is a precursor of advancement, examining conditions fostering female leadership aspiration is important. A neglected perspective is the impact of organizational identification.

  16. Enhancement of ultrasonic disintegration of sewage sludge by aeration.

    Science.gov (United States)

    Zhao, He; Zhang, Panyue; Zhang, Guangming; Cheng, Rong

    2016-04-01

    Sonication is an effective way for sludge disintegration, which can significantly improve the efficiency of anaerobic digestion to reduce and recycle use of sludge. But high energy consumption limits the wide application of sonication. In order to improve ultrasonic sludge disintegration efficiency and reduce energy consumption, aeration was introduced. Results showed that sludge disintegration efficiency was improved significantly by combining aeration with ultrasound. The aeration flow rate, gas bubble size, ultrasonic density and aeration timing had impacts on sludge disintegration efficiency. Aeration that used in later stage of ultrasonic irradiation with low aeration flow rate, small gas bubbles significantly improved ultrasonic disintegration sludge efficiency. At the optimal conditions of 0.4 W/mL ultrasonic irradiation density, 30 mL/min of aeration flow rate, 5 min of aeration in later stage and small gas bubbles, ultrasonic sludge disintegration efficiency was increased by 45% and one third of ultrasonic energy was saved. This approach will greatly benefit the application of ultrasonic sludge disintegration and strongly promote the treatment and recycle of wastewater sludge. Copyright © 2015. Published by Elsevier B.V.

  17. Ultrasonic sectional imaging for crack identification. Part 1. Confirmation test of essential factors for ultrasonic imaging

    International Nuclear Information System (INIS)

    Sasahara, Toshihiko

    2008-01-01

    Since the first reports of inter-granular stress corrosion crack (IGSCC) in boiling water reactor (BWR) pipe in the 1970s, nuclear power industry has focused considerable attention on service induced crack detection and sizing using ultrasonic examination. In recent years, phased array systems, those reconstruct high quality flaw images at real time are getting to apply for crack detection and sizing. But because the price of phased array systems are expensive for inspection vendors, field application of phased array systems are limited and reliable ultrasonic imaging systems with reasonable price are expected. This paper will discuss cost effective ultrasonic equipment with sectional image (B-scan) presentation as the simplified imaging system for assisting ultrasonic examination personnel. To develop the simplified B-scan imaging system, the frequency characteristics of IGSCC echoes and neighboring geometry echoes such as base-metal to weld interface and inner surface of a pipe are studied. The experimental study confirmed the reflectors have different frequency characteristics and 2MHz is suitable to visualize IGSCC and 5MHz and higher frequency are suitable to reconstruct geometry images. The other study is the amplifier selection for the imaging system. To reconstruct images of IGSCC and geometry echoes, the ultrasonic imaging instrument with linear amplifier has to adjust gain setting to the target. On the other hand, the ultrasonic imaging instrument with logarithmic amplifier can collect and display wider dynamic range on a screen and this wider dynamic range are effective to visualize IGSCC and geometry echoes on a B-scan presentation at a time. (author)

  18. Resonant difference-frequency atomic force ultrasonic microscope

    Science.gov (United States)

    Cantrell, John H. (Inventor); Cantrell, Sean A. (Inventor)

    2010-01-01

    A scanning probe microscope and methodology called resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope, driven at a frequency differing from the ultrasonic frequency by one of the contact resonance frequencies of the cantilever, engages the sample top surface. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave in the region defined by the cantilever tip-sample surface interaction force generates difference-frequency oscillations at the cantilever contact resonance. The resonance-enhanced difference-frequency signals are used to create images of nanoscale near-surface and subsurface features.

  19. Recent progress in online ultrasonic process monitoring

    Science.gov (United States)

    Wen, Szu-Sheng L.; Chen, Tzu-Fang; Ramos-Franca, Demartonne; Nguyen, Ky T.; Jen, Cheng-Kuei; Ihara, Ikuo; Derdouri, A.; Garcia-Rejon, Andres

    1998-03-01

    On-line ultrasonic monitoring of polymer co-extrusion and gas-assisted injection molding are presented. During the co- extrusion of high density polyethylene and Santoprene ultrasonic sensors consisting of piezoelectric transducers and clad ultrasonic buffer rods are used to detect the interface between these two polymers and the stability of the extrusion. The same ultrasonic sensor also measures the surface temperature of the extruded polymer. The results indicate that temperature measurements using ultrasound have a faster response time than those obtained by conventional thermocouple. In gas-assisted injection molding the polymer and gas flow front positions are monitored simultaneously. This information may be used to control the plunger movement.

  20. Endotracheal tubes and fluid aspiration: an in vitro evaluation of new cuff technologies.

    Science.gov (United States)

    Mariyaselvam, Maryanne Z; Marsh, Lucy L; Bamford, Sarah; Smith, Ann; Wise, Matt P; Williams, David W

    2017-03-04

    Aspiration of subglottic secretions past the endotracheal tube (ETT) cuff is a prerequisite for developing ventilator-associated pneumonia (VAP). Subglottic secretion drainage (SSD) ETTs reduce aspiration of subglottic secretions and have demonstrated lower VAP rates. We compared the performance of seven SSD ETTs against a non-SSD ETT in preventing aspiration below inflated cuffs. ETTs were positioned vertically in 2 cm diameter cylinders. Four ml of a standard microbial suspension was added above inflated cuffs. After 1 h, aspiration was measured and ETTs demonstrating no leakage were subjected to rotational movement and evaluation over 24 h. Collected aspirated fluid was used to inoculate agar media and incubated aerobically at 37 °C for 24 h. The aspiration rate, volume and number of microorganisms that leaked past the cuff was measured. Experiments were repeated (×10) for each type of ETT, with new ETTs used for each repeat. Best performing ETTs were then tested in five different cylinder diameters (1.6, 1.8, 2.0, 2.2 and 2.4 cm). Experiments were repeated as above using sterile water. Volume and time taken for aspiration past the cuff was measured. Experiments were repeated (×10) for each type of ETT. Results were analysed using non-parametric tests for repeated measures. The PneuX ETT prevented aspiration past the cuff in all experiments. All other ETTs allowed aspiration, with considerable variability in performance. The PneuX ETT was statistically superior in reducing aspiration compared to the SealGuard (p aspiration across the range of diameters compared to the SealGuard (p aspiration, relating to cuff material and design. Variability in performance was likely due to the random manner in which involutional folds form in the inflated ETT cuff. The PneuX ETT was the only ETT able to consistently prevent aspiration past the cuff in all experiments.

  1. Auto-positioning ultrasonic transducer system

    Science.gov (United States)

    Buchanan, Randy K. (Inventor)

    2010-01-01

    An ultrasonic transducer apparatus and process for determining the optimal transducer position for flow measurement along a conduit outer surface. The apparatus includes a transmitting transducer for transmitting an ultrasonic signal, said transducer affixed to a conduit outer surface; a guide rail attached to a receiving transducer for guiding movement of a receiving transducer along the conduit outer surface, wherein the receiving transducer receives an ultrasonic signal from the transmitting transducer and sends a signal to a data acquisition system; and a motor for moving the receiving transducer along the guide rail, wherein the motor is controlled by a controller. The method includes affixing a transmitting transducer to an outer surface of a conduit; moving a receiving transducer on the conduit outer surface, wherein the receiving transducer is moved along a guide rail by a motor; transmitting an ultrasonic signal from the transmitting transducer that is received by the receiving transducer; communicating the signal received by the receiving transducer to a data acquisition and control system; and repeating the moving, transmitting, and communicating along a length of the conduit.

  2. Aspirations langagieres: Negociation et apprentissage du francais (Language Aspirations: Negotiation and Learning French).

    Science.gov (United States)

    Lepetit, Daniel; Cichocki, Wladyslaw

    1990-01-01

    A survey of 130 beginning French students at the University of Windsor (Canada) focused on their second language aspirations, expectations, and anticipated needs. Interpersonal relations appear to be the primary motivator, with travel and instrumental motivation secondary. (20 references) (Author/MSE)

  3. Intergenerational Transmission of Educational Aspirations in Chinese Families: Identifying Mediators and Moderators.

    Science.gov (United States)

    Wu, Nini; Hou, Yang; Wang, Qian; Yu, Chengfu

    2018-06-01

    Parents' educational aspirations for youth play an important role in shaping youth's own educational aspirations; however, little is known about how and in what context parents may transmit their aspirations to youth effectively. This is of particular interest and import to be examined in Chinese families, given Chinese cultural emphasis on educational achievement and Chinese youth's outstanding academic performance internationally. By integrating several key theories of motivation and parental socialization (i.e., the expectancy-value model of academic achievement, the two-step model of value transmission, the contextual model of parenting, and the self-determination theory), the current study investigated simultaneously the mediating roles of parental involvement in youth's learning and youth's perceptions of parental aspirations, as well as the moderating role of parental warmth in the intergenerational transmission process of educational aspirations in Chinese families. A two-wave longitudinal study spanning about half a year was conducted among 323 Chinese seventh graders (54% female; M age  = 13.25 years) and one of their parents (median educational attainment = completion of high school, median monthly income = USD 766-1226). It was found that parental educational aspirations for youth were related positively both indirectly through parental involvement and directly to youth's perceptions of parental aspirations, which in turn were associated positively with youth's own educational aspirations about half a year later. It was also found that parental educational aspirations for youth and youth's own educational aspirations were associated positively with each other only when youth reported experiencing high levels of parental warmth, but unrelated when youth reported experiencing low levels of parental warmth, whereas such moderating effects of parental warmth were absent on the links from parental aspirations to youth's perceptions of parental

  4. Swiss Adolescents' Career Aspirations: Influence of Context, Age, and Career Adaptability

    Science.gov (United States)

    Hirschi, Andreas

    2010-01-01

    This study investigated the content, realism, stability, and coherence of the career aspirations of 262 students in seventh grade in Switzerland (ages 13-15 years). The content analysis revealed that 82% of the participants named at least one realistic career aspiration, and aspirations showed clear resemblance to existing opportunities in the…

  5. Gender and Leadership Aspiration: The Impact of the Organizational Environment

    OpenAIRE

    Fritz, Claudia

    2016-01-01

    markdownabstractSummary The aim of this dissertation is to examine gender differences in leadership aspiration. Although some important work regarding gender-specific aspiration has been done already, conditions fostering leadership aspiration – particularly among women – are not completely understood. Therefore, the focus of this dissertation is on assessing the potential impact of the organizational environment, including formal and informal elements, as well as relevant actors and their re...

  6. [Sequential monitoring of renal transplant with aspiration cytology].

    Science.gov (United States)

    Manfro, R C; Gonçalves, L F; de Moura, L A

    1998-01-01

    To evaluate the utility of kidney aspiration cytology in the sequential monitorization of acute rejection in renal transplant patients. Thirty patients were submitted to 376 aspirations. The clinical diagnoses were independently established. The representativity of the samples reached 82.7%. The total corrected increment index and the number of immunoactivated cells were higher during acute rejection as compared to normal allograft function, acute tubular necrosis, and cyclosporine nephrotoxicity. The parameters to the diagnosis of acute rejection were sensitivity: 71.8%, specificity: 87.3%, positive predictive value: 50.9%, negative predictive value: 94.9% and accuracy 84.9%. The false positive results were mainly related to cytomegalovirus infection or to the administration of OKT3. In 10 out of 11 false negative results incipient immunoactivation was present alerting to the possibility of acute rejection. Kidney aspiration cytology is a useful tool for the sequential monitorization of acute rejection in renal transplant patients. The best results are reached when the results of aspiration cytology are analyzed with the clinical data.

  7. Hand Gesture Recognition Using Ultrasonic Waves

    KAUST Repository

    AlSharif, Mohammed Hussain

    2016-04-01

    Gesturing is a natural way of communication between people and is used in our everyday conversations. Hand gesture recognition systems are used in many applications in a wide variety of fields, such as mobile phone applications, smart TVs, video gaming, etc. With the advances in human-computer interaction technology, gesture recognition is becoming an active research area. There are two types of devices to detect gestures; contact based devices and contactless devices. Using ultrasonic waves for determining gestures is one of the ways that is employed in contactless devices. Hand gesture recognition utilizing ultrasonic waves will be the focus of this thesis work. This thesis presents a new method for detecting and classifying a predefined set of hand gestures using a single ultrasonic transmitter and a single ultrasonic receiver. This method uses a linear frequency modulated ultrasonic signal. The ultrasonic signal is designed to meet the project requirements such as the update rate, the range of detection, etc. Also, it needs to overcome hardware limitations such as the limited output power, transmitter, and receiver bandwidth, etc. The method can be adapted to other hardware setups. Gestures are identified based on two main features; range estimation of the moving hand and received signal strength (RSS). These two factors are estimated using two simple methods; channel impulse response (CIR) and cross correlation (CC) of the reflected ultrasonic signal from the gesturing hand. A customized simple hardware setup was used to classify a set of hand gestures with high accuracy. The detection and classification were done using methods of low computational cost. This makes the proposed method to have a great potential for the implementation in many devices including laptops and mobile phones. The predefined set of gestures can be used for many control applications.

  8. Ultrasonic wave propagation in powders

    Science.gov (United States)

    Al-Lashi, R. S.; Povey, M. J. W.; Watson, N. J.

    2018-05-01

    Powder clumps (cakes) has a significant effect on the flowability and stability of powders. Powder caking is mainly caused by moisture migration due to wetting and environmental (temperature and humidity) changes. The process of moisture migration caking involves creating liquid bridges between the particles during condensation which subsequently harden to form solid bridges. Therefore, an effective and reliable technique is required to quantitatively and non-invasively monitor caking kinetics and effective stiffness. This paper describes two ultrasonic instruments (ultrasonic velocity pulse and airborne ultrasound systems) that have been used to monitor the caking phenomenon. Also, it discusses the relationship between the ultrasonic velocity and attenuation measurements and tracking caking kinetics and the effective stiffness of powders.

  9. Standard practice for leaks using ultrasonics

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 Practice A, Pressurization—This practice covers procedures for calibration of ultrasonic instruments, location, and estimated measurements of gas leakage to atmosphere by the airborne ultrasonic technique. 1.2 In general practice this should be limited to leaks detected by two classifications of instruments, Class I and Class II. Class I instruments should have a minimum detectable leak rate of 6.7 × 10−7 mol/s (1.5 × 10−2 std. cm3/s at 0°C) or more for the pressure method of gas leakage to atmosphere. Class II instruments should have a minimal detectable leak rate of 6.7 × 10−6 mol/s (1.5 × 10−1 std. cm3/s at 0°C) or more for the pressure method of gas leakage to atmosphere. Refer to Guide E432 for additional information. 1.3 Practice B, Ultrasonic Transmitter—For object under test not capable of being pressurized but capable of having ultrasonic tone placed/injected into the test area to act as an ultrasonic leak trace source. 1.3.1 This practice is limited to leaks producing leakage o...

  10. Applications of a nanocomposite-inspired in-situ broadband ultrasonic sensor to acousto-ultrasonics-based passive and active structural health monitoring.

    Science.gov (United States)

    Liu, Menglong; Zeng, Zhihui; Xu, Hao; Liao, Yaozhong; Zhou, Limin; Zhang, Zhong; Su, Zhongqing

    2017-07-01

    A novel nanocomposite-inspired in-situ broadband ultrasonic sensor previously developed, with carbon black as the nanofiller and polyvinylidene fluoride as the matrix, was networked for acousto-ultrasonic wave-based passive and active structural health monitoring (SHM). Being lightweight and small, this kind of sensor was proven to be capable of perceiving strain perturbation in virtue of the tunneling effect in the formed nanofiller conductive network when acousto-ultrasonic waves traverse the sensor. Proof-of-concept validation was implemented, to examine the sensor performance in responding to acousto-ultrasonic waves in a broad frequency regime: from acoustic emission (AE) of lower frequencies to guided ultrasonic waves (GUWs) of higher frequencies. Results have demonstrated the high fidelity, ultrafast response and high sensitivity of the sensor to acousto-ultrasonic waves up to 400kHz yet with an ultra-low magnitude (of the order of micro-strain). The sensor is proven to possess sensitivity and accuracy comparable with commercial piezoelectric ultrasonic transducers, whereas with greater flexibility in accommodating curved structural surfaces. Application paradigms of using the sensor for damage evaluation have spotlighted the capability of the sensor in compromising "sensing cost" with "sensing effectiveness" for passive AE- or active GUW-based SHM. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Development of an ultrasonic process for soil remediation

    International Nuclear Information System (INIS)

    Wu, J.M.; Huang, H.S.; Livengood, C.D.

    1995-01-01

    An ultrasonic process for the detoxification of carbon tetrachloride- (CCl 4 - ) contaminated soil was investigated in the laboratory by using a batch irradiation reactor equipped with a 600-W ultrasonic power supply operated at a frequency of 20 kHz. Key parameters studied included soil characteristics, irradiation time, CCl 4 concentration, steady-state operating temperature, applied ultrasonic-wave energy, and the ratio of soil to water in the system. The results of the experiments showed that (1) residual CCl 4 concentrations could be decreased with longer irradiation periods and (2) detoxification efficiency was proportional to steady-state operating temperature and applied ultrasonic-wave energy. The characteristics of the contaminated soil were found to be an important factor in the design of an ultrasonic detoxification system. A soil-phase CCl 4 concentration below 1 ppm (initial concentration of 56 ppm) was achieved through this process, indicating that the application of ultrasonic irradiation is feasible and effective in the detoxification of soil contaminated by organic compounds. On the basis of the experimental results, a schematic of a full-scale ultrasonic soil-detoxification system was developed. Improvements to this novel process are discussed

  12. Ultrasonic characterization of vegetable oil product

    International Nuclear Information System (INIS)

    Sidek Hj Abd Aziz; Chow Sai Pew; Abdul Halim Shaari; Nor Azizah Shaari

    1992-01-01

    The ultrasonic wave velocity and attenuation of a number vegetable oil products were measured using an ultrasonic pulse echo overlap technique from room temperature up to 90 0 C. Among the liquid samples studied were refined bleach deodorized (RED) palm oil, palm olein, coconut oil, corn oil and soya bean oil. The velocity of sound in vegetable oil products varies from about 1200 to 200 ms-1 and decrease linearly as the temperature increases. The ultrasonic properties of the oil are much dependent on their viscosity, density, relaxation effect and vibrational anharmonicity

  13. The Role of Aspirations in Young Children's Emotional and Behavioural Problems

    Science.gov (United States)

    Moulton, Vanessa; Flouri, Eirini; Joshi, Heather; Sullivan, Alice

    2015-01-01

    Using data from a large UK cohort (n = 11,656), we investigated the determinants of 7-year-old children's aspirations, and the role of these aspirations in emotional and behavioural problems, as reported by both parents and teachers. Aspirations were classified to reflect their occupational status, masculinity/femininity and intrinsic/extrinsic…

  14. Empowering change: The effects of energy provision on individual aspirations in slum communities

    International Nuclear Information System (INIS)

    Parikh, Priti; Chaturvedi, Sankalp; George, Gerard

    2012-01-01

    This paper discusses the role of energy provision in influencing the social aspirations of people living in slums. We examine factors that influence the shift in aspirations in five slum settlements using data from 500 interviews conducted in serviced and non-serviced slums from the state of Gujarat in India. The non-serviced slums did not have access to basic services namely water, sanitation, energy, roads, solid waste and rainwater management. We find empirical evidence which suggests that when basic infrastructure provisions are met, slum dwellers shift their focus from lower order aspirations to the higher order aspirations like health, education, housing and land ownership. We argue that energy provision enhances productivity and enables slum dwellers to shift their aspirations upwards. Furthermore, we test the effect of work days lost due to illness on the relationship between higher order aspirations and aspirations for energy provision. When provision of energy is low, higher work day loss dampens higher order aspirations. For policy makers, this study highlights the critical link between the infrastructure services preferred by slum dwellers and their social aspirations for growth. - Highlights: ► We examine the role of energy provision in influencing social aspirations of people living in slums. ► 500 household interviews conducted in five Indian slum settlements used for the analysis. ► Shift in slum dwellers aspirations from non-serviced to serviced conditions examined using Herzberg’s theory. ► Link between energy provision and higher order aspirations established through a regression model. ► Policy recommendation is to encourage investment in infrastructure services as a driver for development.

  15. Aspiration and sclerotherapy versus hydrocoelectomy for treating hydrocoeles.

    Science.gov (United States)

    Shakiba, Behnam; Heidari, Kazem; Jamali, Arsia; Afshar, Kourosh

    2014-11-13

    Hydrocoeles are common cystic scrotal abnormalities, described as a fluid-filled collection between the visceral and parietal layers of the tunica vaginalis of the scrotum. There are two approaches for treatment of hydrocoeles: surgical open hydrocoelectomy and aspiration followed by sclerotherapy.  We compared the benefits and harms of aspiration and sclerotherapy versus hydrocoelectomy for the management of hydrocoeles. We searched the Cochrane Renal Group's Specialised Register to 2 August 2014 through contact with the Trials' Search Co-ordinator using search terms relevant to this review. Randomised controlled trials (RCTs) and quasi-RCTs comparing aspiration and sclerotherapy versus hydrocoelectomy for the management of hydrocoeles. Two authors independently extracted data and assessed risk of bias in the included studies. Random effects meta-analyses were performed using relative risk (RR) for dichotomous outcomes and mean differences (MD) for continuous outcomes, with 95% confidence intervals (CI). We found four small studies that met the inclusion criteria. These studies enrolled 275 patients with 282 hydroceles. Participants were randomised to aspiration and sclerotherapy (155 patients with 159 hydroceles) and surgery (120 patients with 123 hydroceles). All studies were assessed as having low or unclear risk of bias for selection bias, detection bias, attrition bias and selective reporting bias. Blinding was not possible for participants and investigators based on the type of interventions. Blinding for statisticians was not reported in any of included studies.There were no significant difference in clinical cure between the two groups (3 studies, 215 participants: RR 0.45, 95% CI 0.18 to 1.10), however there was significant heterogeneity (I² = 95%). On further investigation one study contributed all of the heterogeneity. This could be due to the agent used or perhaps due to the fact that this is a much older study than the other two studies included in

  16. Remediation of Diesel Fuel Contaminated Sandy Soil using Ultrasonic Waves

    Directory of Open Access Journals (Sweden)

    Wulandari P.S.

    2010-01-01

    Full Text Available Ultrasonic cleaning has been used in industry for some time, but the application of ultrasonic cleaning in contaminated soil is just recently received considerable attention, it is a very new technique, especially in Indonesia. An ultrasonic cleaner works mostly by energy released from the collapse of millions of microscopic cavitations near the dirty surface. This paper investigates the use of ultrasonic wave to enhance remediation of diesel fuel contaminated sandy soil considering the ultrasonic power, soil particle size, soil density, water flow rate, and duration of ultrasonic waves application.

  17. The Dynamic Performance of Flexural Ultrasonic Transducers

    Directory of Open Access Journals (Sweden)

    Andrew Feeney

    2018-01-01

    Full Text Available Flexural ultrasonic transducers are principally used as proximity sensors and for industrial metrology. Their operation relies on a piezoelectric ceramic to generate a flexing of a metallic membrane, which delivers the ultrasound signal. The performance of flexural ultrasonic transducers has been largely limited to excitation through a short voltage burst signal at a designated mechanical resonance frequency. However, a steady-state amplitude response is not generated instantaneously in a flexural ultrasonic transducer from a drive excitation signal, and differences in the drive characteristics between transmitting and receiving transducers can affect the measured response. This research investigates the dynamic performance of flexural ultrasonic transducers using acoustic microphone measurements and laser Doppler vibrometry, supported by a detailed mechanical analog model, in a process which has not before been applied to the flexural ultrasonic transducer. These techniques are employed to gain insights into the physics of their vibration behaviour, vital for the optimisation of industrial ultrasound systems.

  18. The detection of pharyngeal incoordination and aspiration by radiosalivagram in cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Baikie, G.; Reddihough, D.; Olinsky, A.; South, M.J.; Bowe, J.; Cook, D.J. [Royal Children`s Hospital, Parkville, VIC, (Australia)

    1997-09-01

    Full text: Children with cerebral palsy (CP) may have abnormal respiratory function because of aspiration pneumonitis, chest deformity, upper airways obstruction or central respiratory control abnormalities. The diagnosis of aspiration has long confounded clinicians and is often made indirectly after exclusion of other causes of respiratory disease in susceptible individuals. The radiosalivagram is a technique which permits the demonstration of aspiration of pharyngeal contents in individuals with pharyngeal incoordination. It is a simple procedure which provides both qualitative and quantitative evidence of aspiration. Over an hour and while supine, 20 mL of {sup 99m}Tc-sulphur colloid is instilled into the pharynx via a thin plastic tube using a syringe pump. The neck, thorax and upper abdomen are imaged continuously In normal individuals, radioactivity is demonstrated in the pharynx, oesophagus and stomach; in the presence of pharyngeal incoordination, radioactivity is seen within one or both main bronchi and adjacent lung fields. The rate of clearance from the lungs varies and can be quantified. We have studied 31 children with severe non-ambulant CR The time to first aspiration, maximum quantity aspirated, and retention of aspirated material at 2h have been determined. These data have been compared with measurements of respiratory function. Preliminary results of this ongoing study reveal a broad range of outcomes. Seventeen children (17/31) had aspiration, in 15/17 aspiration was unilateral and in 14/17 there was spontaneous early clearance. The investigation was well tolerated by patients. The radiosalivagram is a simple, quantifiable investigation for demonstrating or excluding pharyngeal incoordination and aspiration in children with unexplained respiratory disease.

  19. The detection of pharyngeal incoordination and aspiration by radiosalivagram in cerebral palsy

    International Nuclear Information System (INIS)

    Baikie, G.; Reddihough, D.; Olinsky, A.; South, M.J.; Bowe, J.; Cook, D.J.

    1997-01-01

    Full text: Children with cerebral palsy (CP) may have abnormal respiratory function because of aspiration pneumonitis, chest deformity, upper airways obstruction or central respiratory control abnormalities. The diagnosis of aspiration has long confounded clinicians and is often made indirectly after exclusion of other causes of respiratory disease in susceptible individuals. The radiosalivagram is a technique which permits the demonstration of aspiration of pharyngeal contents in individuals with pharyngeal incoordination. It is a simple procedure which provides both qualitative and quantitative evidence of aspiration. Over an hour and while supine, 20 mL of 99m Tc-sulphur colloid is instilled into the pharynx via a thin plastic tube using a syringe pump. The neck, thorax and upper abdomen are imaged continuously In normal individuals, radioactivity is demonstrated in the pharynx, oesophagus and stomach; in the presence of pharyngeal incoordination, radioactivity is seen within one or both main bronchi and adjacent lung fields. The rate of clearance from the lungs varies and can be quantified. We have studied 31 children with severe non-ambulant CR The time to first aspiration, maximum quantity aspirated, and retention of aspirated material at 2h have been determined. These data have been compared with measurements of respiratory function. Preliminary results of this ongoing study reveal a broad range of outcomes. Seventeen children (17/31) had aspiration, in 15/17 aspiration was unilateral and in 14/17 there was spontaneous early clearance. The investigation was well tolerated by patients. The radiosalivagram is a simple, quantifiable investigation for demonstrating or excluding pharyngeal incoordination and aspiration in children with unexplained respiratory disease

  20. Aspirations and occupational achievements of Dutch fathers and mothers

    NARCIS (Netherlands)

    van der Horst, Mariska; van der Lippe, Tanja; Kluwer, Esther

    2014-01-01

    Purpose – The purpose of this paper is to investigate how work and family aspirations relate to occupational achievements and gender differences herein. Design/methodology/approach – Using data from 2009 the authors examined the relationship between career and childrearing aspirations and

  1. A Portable Ultrasound System for Non-Invasive Ultrasonic Neuro-Stimulation.

    Science.gov (United States)

    Qiu, Weibao; Zhou, Juan; Chen, Yan; Su, Min; Li, Guofeng; Zhao, Huixia; Gu, Xianyi; Meng, De; Wang, Congzhi; Xiao, Yang; Lam, Kwok Ho; Dai, Jiyan; Zheng, Hairong

    2017-12-01

    Fundamental insights into the function of the neural circuits often follows from the advances in methodologies and tools for neuroscience. Electrode- and optical- based stimulation methods have been used widely for neuro-modulation with high resolution. However, they are suffering from inherent invasive surgical procedure. Ultrasound has been proved as a promising technology for neuro-stimulation in a non-invasive manner. However, no portable ultrasound system has been developed particularly for neuro-stimulation. The utilities used currently are assembled by traditional functional generator, power amplifier, and general transducer, therefore, resulting in lack of flexibility. This paper presents a portable system to achieve ultrasonic neuro-stimulation to satisfy various studies. The system incorporated a high voltage waveform generator and a matching circuit that were optimized for neuro-stimulation. A new switching mode power amplifier was designed and fabricated. The noise generated by the power amplifier was reduced (about 30 dB), and the size and weight were smaller in contrast with commercial equipment. In addition, a miniaturized ultrasound transducer was fabricated using Pb(Mg 1/3 Nb 2/3 )O 3 -PbTiO 3 (PMN-PT) 1-3 composite single crystal for the improved ultrasonic performance. The spatial peak temporal average pressure was higher than 250 kPa in the range of 0.5-5 MHz. In vitro and in vivo studies were conducted to show the performance of the system.

  2. Lithium niobate ultrasonic transducer design for Enhanced Oil Recovery.

    Science.gov (United States)

    Wang, Zhenjun; Xu, Yuanming; Gu, Yuting

    2015-11-01

    Due to the strong piezoelectric effect possessed by lithium niobate, a new idea that uses lithium niobate to design high-power ultrasonic transducer for Enhanced Oil Recovery technology is proposed. The purpose of this paper is to lay the foundation for the further research and development of high-power ultrasonic oil production technique. The main contents of this paper are as follows: firstly, structure design technique and application of a new high-power ultrasonic transducer are introduced; secondly, the experiment for reducing the viscosity of super heavy oil by this transducer is done, the optimum ultrasonic parameters for reducing the viscosity of super heavy oil are given. Experimental results show that heavy large molecules in super heavy oil can be cracked into light hydrocarbon substances under strong cavitation effect caused by high-intensity ultrasonic wave. Experiment proves that it is indeed feasible to design high-power ultrasonic transducer for ultrasonic oil production technology using lithium niobate. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. An Aspirational Community Theory of the Firm

    DEFF Research Database (Denmark)

    Li, Xin

    propose an aspirational community theory of the firm (ACT) as a candidate theory by conceptualizing the firm as an aspirational community, the core of which is a group of like-minded people sharing similar or same aspiration/vision. To explain the existence of the firm, we make a distinction between......All of the three major theories of the firm, i.e., the transaction cost theory, knowledge-based theory and the entrepreneurship theory, offer some insightful analyses of the nature of the firm. However, they all have limitations and weaknesses in answering the fundamental question of the existence...... of the firm. In addition, they are all partial due to their particular focus on the multifaceted phenomenon of the firm. We argue that it is necessary and sufficient to develop a comprehensive yet integrative theory of the firm that combines the three competing yet complementary logics. Toward this end, we...

  4. Degradation of acephate using combined ultrasonic and ozonation method

    Directory of Open Access Journals (Sweden)

    Bin Wang

    2015-07-01

    Full Text Available The degradation of acephate in aqueous solutions was investigated with the ultrasonic and ozonation methods, as well as a combination of both. An experimental facility was designed and operation parameters such as the ultrasonic power, temperature, and gas flow rate were strictly controlled at constant levels. The frequency of the ultrasonic wave was 160 kHz. The ultraviolet-visible (UV-Vis spectroscopic and Raman spectroscopic techniques were used in the experiment. The UV-Vis spectroscopic results show that ultrasonication and ozonation have a synergistic effect in the combined system. The degradation efficiency of acephate increases from 60.6% to 87.6% after the solution is irradiated by a 160 kHz ultrasonic wave for 60 min in the ozonation process, and it is higher with the combined method than the sum of the separated ultrasonic and ozonation methods. Raman spectra studies show that degradation via the combined ultrasonic/ozonation method is more thorough than photocatalysis. The oxidability of nitrogen atoms is promoted under ultrasonic waves. Changes of the inorganic ions and degradation pathway during the degradation process were investigated in this study. Most final products are innocuous to the environment.

  5. Ultrasonic Abrasive Removal Of EDM Recast

    Science.gov (United States)

    Mandel, Johnny L.; Jacobson, Marlowe S.

    1990-01-01

    Ultrasonic abrasive process removes layer of recast material generated during electrical-discharge machining (EDM) of damper pocket on turbine blade. Form-fitted tool vibrated ultrasonically in damper pocket from which material removed. Vibrations activate abrasive in pocket. Amount of material removed controlled precisely.

  6. Fundamentals of Medical Ultrasonics

    CERN Document Server

    Postema, Michiel

    2011-01-01

    This book sets out the physical and engineering principles of acoustics and ultrasound as used for medical applications. It covers the basics of linear acoustics, wave propagation, non-linear acoustics, acoustic properties of tissue, transducer components, and ultrasonic imaging modes, as well as the most common diagnostic and therapeutic applications. It offers students and professionals in medical physics and engineering a detailed overview of the technical aspects of medical ultrasonic imaging, whilst serving as a reference for clinical and research staff.

  7. Assessing ultrasonic examination results

    International Nuclear Information System (INIS)

    Deutsch, V.; Vogt, M.

    1977-01-01

    Amongst nondestructive examination methods, the ultrasonic examination plays an important role. The reason why its scope of application is so wide is because the sound conducting capacity is the only property the material of a test specimen has to have. As the fields are so manifold, only main aspects can be described briefly. The list of references, however, is very extensive and gives plenty of information of all the problems concerning the assessment of ultrasonic examination results. (orig./RW) [de

  8. Surgical Treatment of Acute Pancreatitis.

    Science.gov (United States)

    Werner, Jens; Uhl, Waldemar; Büchler, Markus W.

    2003-10-01

    Patients with predicted severe necrotizing pancreatitis as diagnosed by C-reactive protein (>150 mg/L) and/or contrast-enhanced computed tomography should be managed in the intensive care unit. Prophylactic broad-spectrum antibiotics reduce infection rates and survival in severe necrotizing pancreatitis. Endoscopic retrograde cholangiopancreatography and endoscopic sphincterotomy is a causative therapy for gallstone pancreatitis with impacted stones, biliary sepsis, or obstructive jaundice. Fine needle aspiration for bacteriology should be performed to differentiate between sterile and infected pancreatic necrosis in patients with sepsis syndrome. Infected pancreatic necrosis in patients with clinical signs and symptoms of sepsis is an indication for surgery. Patients with sterile pancreatic necrosis should be managed conservatively. Surgery in patients with sterile necrosis may be indicated in cases of persistent necrotizing pancreatitis and in the rare cases of "fulminant acute pancreatitis." Early surgery, within 14 days after onset of the disease, is not recommended in patients with necrotizing pancreatitis. The surgical approach should be organ-preserving (debridement/necrosectomy) and combined with a postoperative management concept that maximizes postoperative evacuation of retroperitoneal debris and exudate. Minimally invasive surgical procedures have to be regarded as an experimental approach and should be restricted to controlled trials. Cholecystectomy should be performed to avoid recurrence of gallstone-associated acute pancreatitis.

  9. Ultrasonically-assisted Thermal Stir Welding System

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2014-01-01

    A welding head assembly has a work piece disposed between its containment plates' opposing surfaces with the work piece being maintained in a plastic state thereof at least in a vicinity of the welding head assembly's stir rod as the rod is rotated about its longitudinal axis. The welding head assembly and the work piece experience relative movement there between in a direction perpendicular to the rod's longitudinal axis as the work piece is subjected to a compressive force applied by the containment plates. A first source coupled to the first containment plate applies a first ultrasonic wave thereto such that the first ultrasonic wave propagates parallel to the direction of relative movement. A second source coupled to the second containment plate applies a second ultrasonic wave thereto such that the second ultrasonic wave propagates parallel to the direction of relative movement.propagates parallel to the direction of relative movement.

  10. Cold Antimatter Plasmas, and Aspirations for Cold Antihydrogen

    Science.gov (United States)

    2002-06-24

    UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADP012494 TITLE: Cold Antimatter Plasmas, and Aspirations for Cold...part numbers comprise the compilation report: ADP012489 thru ADP012577 UNCLASSIFIED Cold Antimatter Plasmas, and Aspirations for Cold Antihydrogen G...and positrons. The antiprotons come initially from the new Antiproton Decel- erator facility at CERN. Good control of such cold antimatter plasmas is

  11. Ultrasonic implant site preparation using piezosurgery: a multicenter case series study analyzing 3,579 implants with a 1- to 3-year follow-up.

    Science.gov (United States)

    Vercellotti, Tomaso; Stacchi, Claudio; Russo, Crescenzo; Rebaudi, Alberto; Vincenzi, Giampaolo; Pratella, Umberto; Baldi, Domenico; Mozzati, Marco; Monagheddu, Chiara; Sentineri, Rosario; Cuneo, Tommaso; Di Alberti, Luca; Carossa, Stefano; Schierano, Gianmario

    2014-01-01

    This multicenter case series introduces an innovative ultrasonic implant site preparation (UISP) technique as an alternative to the use of traditional rotary instruments. A total of 3,579 implants were inserted in 1,885 subjects, and the sites were prepared using a specific ultrasonic device with a 1- to 3-year follow-up. No surgical complications related to the UISP protocol were reported for any of the implant sites. Seventy-eight implants (59 maxillary, 19 mandibular) failed within 5 months of insertion, for an overall osseointegration percentage of 97.82% (97.14% maxilla, 98.75% mandible). Three maxillary implants failed after 3 years of loading, with an overall implant survival rate of 97.74% (96.99% maxilla, 98.75% mandible).

  12. [Effects of ultrasonic pretreatment on drying characteristics of sewage sludge].

    Science.gov (United States)

    Li, Run-Dong; Yang, Yu-Ting; Li, Yan-Long; Niu, Hui-Chang; Wei, Li-Hong; Sun, Yang; Ke, Xin

    2009-11-01

    The high water content of sewage sludge has engendered many inconveniences to its treatment and disposal. While ultrasonic takes on unique advantages on the sludge drying because of its high ultrasonic power, mighty penetrating capability and the ability of causing cavitations. Thus this research studies the characteristics influences of ultrasonic bring to the sludge drying and effects of the exposure time, ultrasonic generator power, temperatures of ultrasonic and drying temperature on the drying characteristics of dewatered sludge. Results indicate that ultrasonic pretreatment could speed up evaporation of the free water in sludge surface and help to end the drying stage with constant speed. In addition, ultrasonic treatment can effectively improve the sludge drying efficiency which could be more evident with the rise of the ultrasonic power (100-250 W), ultrasonic temperature and drying temperature. If dried under low temperature such as 105 degrees C, sludge will have premium drying characteristics when radiated under ultrasound for a shorter time such as 3 min. In the end, the ultrasonic treatment is expected to be an effective way to the low-cost sludge drying and also be an important reference to the optimization of the sludge drying process because of its effects on the increase of sludge drying efficiency.

  13. Lipid aspiration pneumonia due to gastroesophageal reflux

    International Nuclear Information System (INIS)

    Wolfson, B.J.; Temple Univ., Philadelphia, PA; Allen, J.L.; Panitch, H.B.; Temple Univ., Philadelphia, PA; Karmazin, N.; Temple Univ., Philadelphia, PA

    1989-01-01

    The development of lipid aspiration pneumonia after chronic nasopharyngeal installation of mineral oil was first described in 1925 by Laughlin. Since that time this entity has been well recognized and numerous substances have been identified or implicated as the aspirated material. The classic radiographic appearance of severe chronic lipid aspiration pneumonia has been described as consisting of intense perihilar infiltrates. However, the radiographic findings are more often non-specific and usually consist of varying degrees of diffuse interstitial infiltrates that tend to be more prominent in the perihilar regions and the right lung. We are reporting a case of biopsy-proven lipid aspiration pneumonia in an infant with known gastro-esophageal reflux (GER) who had medium-chain triglyceride oil administered via nasogastric tube. Serial roentgenograms demonstrated a changing pulmonary pattern from diffuse bilateral interstitial infiltrates initially to a diffuse alveolar pattern at the time of the lung biopsy. Modern medicine has developed new methods for providing nourishment to sick newborns and infants to improve their nutritional status and help them to grow. One such method involves the administration of medium-chain triglycerides (MCT oil) into the GI tract via a nasogastric or nasoenteral tube. The purpose of this report is to describe a significant complication of this method of providing nutrition to an infant with gastroesophageal reflux (GER) and the diagnostic dilemma it presented. (orig.)

  14. Development of an intelligent ultrasonic welding defect classification software

    International Nuclear Information System (INIS)

    Song, Sung Jin; Kim, Hak Joon; Jeong, Hee Don

    1997-01-01

    Ultrasonic pattern recognition is the most effective approach to the problem of discriminating types of flaws in weldments based on ultrasonic flaw signals. In spite of significant progress in the research on this methodology, it has not been widely used in many practical ultrasonic inspections of weldments in industry. Hence, for the convenient application of this approach in many practical situations, we develop an intelligent ultrasonic signature classification software which can discriminate types of flaws in weldments based on their ultrasonic signals using various tools in artificial intelligence such as neural networks. This software shows the excellent performance in an experimental problem where flaws in weldments are classified into two categories of cracks and non-cracks. This performance demonstrates the high possibility of this software as a practical tool for ultrasonic flaw classification in weldments.

  15. Backward ray tracing for ultrasonic imaging

    NARCIS (Netherlands)

    Breeuwer, R.

    1990-01-01

    Focused ultrasonic beams frequently pass one or more media interfaces, strongly affecting the ultrasonic beamshape and focusing. A computer program, based on backward ray tracing was developed to compute the shape of a corrected focusing mirror. This shape is verified with another program; then the

  16. 21 CFR 886.4150 - Vitreous aspiration and cutting instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vitreous aspiration and cutting instrument. 886.4150 Section 886.4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... cutting instrument. (a) Identification. A vitreous aspiration and cutting instrument is an electrically...

  17. Overview of the ultrasonic instrumentation research in the MYRRHA project

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, M.; Leysen, W.; Van Dyck, D. [Belgian Nuclear Research Center SCK.CEN (Belgium)

    2015-07-01

    The Belgian Nuclear Research Centre SCK.CEN is in the process of developing MYRRHA, a new generation IV fast flux research reactor to replace the aging BR2. MYRRHA is conceptualized as an accelerator driven system cooled with lead bismuth eutectic mixture (LBE). As LBE is opaque to visual light, ultrasonic measurement techniques are employed as the main technology to provide feedback where needed. This paper we will give an overview of the R and D at SCK.CEN with respect to ultrasonic instrumentation in heavy liquid metals. High temperature ultrasonic transducers are deployed into the reactor to generate and receive the required ultrasonic signals. The ultrasonic waves are generated and sensed by means of a piezo-electric disc at the heart of the transducer. The acoustic properties of commonly used piezo-electric materials match rather well with the acoustic properties of heavy liquid metals, simplifying the design and construction of high bandwidth ultrasonic transducers for use in heavy liquid metals. The ultrasonic transducers will operate in a liquid metal environment, where radiation and high temperature limit the choice of materials for construction. Moreover, the high surface tension of the liquid metal hinders proper wetting of the transducer, required for optimal transmission and reception of the ultrasonic waves. In a first part of the paper, we will discuss the effect of these parameters on the performance of the overall ultrasonic system. In the second part of the paper, past, present and future ultrasonic experiments in LBE will be reviewed. We will show the results of an experiment where a transducer is scanned near the free surface of an LBE pool to render ultrasonic images of objects submerged in the heavy liquid metal. Additionally, the preliminary results of an ongoing experiment that measures the evolution of LBE wetting on different types of metals and various surface conditions will be reported. The evolution of wetting is an important

  18. Ultrasonic testing of materials at level 2

    International Nuclear Information System (INIS)

    1988-06-01

    Ultrasonic inspection is a nondestructive method in which high frequency sound waves are introduced into the material being inspected. Ultrasonic testing has a superior penetrating power to radiography and can detect flaws deep in the test specimen (say up to about 6 to 7 meters of steel). It is quite sensitive to small flaws and allows the precise determination of the location and size of the flaws. Basic ultrasonic test methods such as the through transmission method and the resonance method, sensors and testing techniques are described. Pulse echo type flaw detectors and their applications for inspection of welds are surveyed. Ultrasonic standards, calibration of the equipment and evaluation methods are presented. Examples of practical applications in welding, casting and forging processes are given. Figs and tabs

  19. Interfacing an aspiration ion mobility spectrometer to a triple quadrupole mass spectrometer

    International Nuclear Information System (INIS)

    Adamov, Alexey; Viidanoja, Jyrki; Kaerpaenoja, Esko; Paakkanen, Heikki; Ketola, Raimo A.; Kostiainen, Risto; Sysoev, Alexey; Kotiaho, Tapio

    2007-01-01

    This article presents the combination of an aspiration-type ion mobility spectrometer with a mass spectrometer. The interface between the aspiration ion mobility spectrometer and the mass spectrometer was designed to allow for quick mounting of the aspiration ion mobility spectrometer onto a Sciex API-300 triple quadrupole mass spectrometer. The developed instrumentation is used for gathering fundamental information on aspiration ion mobility spectrometry. Performance of the instrument is demonstrated using 2,6-di-tert-butyl pyridine and dimethyl methylphosphonate

  20. Ultrasonic thermometry for nuclear power plants

    International Nuclear Information System (INIS)

    Saravana Kumar, S.; Arunraj, A.L.R.; Swaminathan, K.

    2013-01-01

    Ultrasonic transducer provides a method of measurement of temperature in industrial tanks and boilers containing different liquids with varied salt content. This method is used to measure the average temperature continuously where other traditional methods available do not offer. Traditional methods used for temperature measurement like infrared thermometers, thermocouples, measures temperature at a single location. Numerous thermocouples are to be fixed at various part of the boiler in order to measure the temperature of the entire boiler, which incurs high cost. Reliability of the system decreases, with increasing number of thermocouples. When they fail at a point, the time incurred in finding the faulty part or faulty thermocouple is high. Ultrasonic transducer provides continuous measurement for all different characteristic liquids with higher accuracy and lesser response time. Fault location and clearance time is also less in ultrasonic measurement method, since only a couple of transducers used for the entire boiler structure. Additionally ultrasonic thermometry along support measuring electronic system can be built of low cost. (author)

  1. Analysis of Ultrasonic Resonance Signal in Multi-Layered Structure

    International Nuclear Information System (INIS)

    Kim, Jae Hoon; Kim, Dong Ryun

    2012-01-01

    Ultrasonic testing are far superior to other nondestructive tests for detecting the disbond interface which occurred in adhesive interface. However, a solid rocket motor consisting of a steel case, rubber insulation, liner, and propellant poses many difficulties for analyzing ultrasonic waves because of the superposition of reflected waves and large differences in acoustic impedance of various materials. Therefore, ultrasonic tests for detecting the disbond interface in solid rocket motor have been applied in very limited areas between the steel case and rubber insulation using an automatic C-scan system. The existing ultrasonic test cannot detect the disbond interface between the liner and propellant of a solid rocket motor because most of the ultrasonic waves are absorbed in the rubber material which has low acoustic impedance. This problem could be overcome by analyzing the resonance frequency from the frequency spectrum using the ultrasonic resonance method. In this paper, a new technique to detect the disbond interface between the liner and propellant using ultrasonic resonance characteristics is discussed in detail.

  2. Analysis of Ultrasonic Resonance Signal in Multi-Layered Structure

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hoon [Dept. of Mechanical Design Engineering, Chungnam National University, Daejeon (Korea, Republic of); Kim, Dong Ryun [Agency for Defense Development, Daejeon (Korea, Republic of)

    2012-08-15

    Ultrasonic testing are far superior to other nondestructive tests for detecting the disbond interface which occurred in adhesive interface. However, a solid rocket motor consisting of a steel case, rubber insulation, liner, and propellant poses many difficulties for analyzing ultrasonic waves because of the superposition of reflected waves and large differences in acoustic impedance of various materials. Therefore, ultrasonic tests for detecting the disbond interface in solid rocket motor have been applied in very limited areas between the steel case and rubber insulation using an automatic C-scan system. The existing ultrasonic test cannot detect the disbond interface between the liner and propellant of a solid rocket motor because most of the ultrasonic waves are absorbed in the rubber material which has low acoustic impedance. This problem could be overcome by analyzing the resonance frequency from the frequency spectrum using the ultrasonic resonance method. In this paper, a new technique to detect the disbond interface between the liner and propellant using ultrasonic resonance characteristics is discussed in detail.

  3. The Path Taken: Consequences of Attaining Intrinsic and Extrinsic Aspirations in Post-College Life.

    Science.gov (United States)

    Niemiec, Christopher P; Ryan, Richard M; Deci, Edward L

    2009-06-01

    Life goals, or aspirations, organize and direct behavior over extended periods of time. The present study, guided by self-determination theory, examined the consequences of pursuing and attaining aspirations over a one-year period in a post-college sample. Results indicated that placing importance on either intrinsic or extrinsic aspirations related positively to attainment of those goals. Yet, whereas attainment of intrinsic aspirations related positively to psychological health, attainment of extrinsic aspirations did not; indeed, attainment of extrinsic aspirations related positively to indicators of ill-being. Also as predicted, the association between change in attainment of intrinsic aspirations and change in psychological health was mediated by change in the satisfaction of the basic psychological needs for autonomy, competence, and relatedness. Discussion focuses on the idea that not all goal attainment is beneficial; rather, attainment of aspirations with different contents relates differentially to psychological health.

  4. Erythropoietin Pretreatment Attenuates Seawater Aspiration-Induced Acute Lung Injury in Rats.

    Science.gov (United States)

    Ji, Mu-Huo; Tong, Jian-Hua; Tan, Yuan-Hui; Cao, Zhen-Yu; Ou, Cong-Yang; Li, Wei-Yan; Yang, Jian-Jun; Peng, Y G; Zhu, Si-Hai

    2016-02-01

    Seawater drowning-induced acute lung injury (ALI) is a serious clinical condition characterized by increased alveolar-capillary permeability, excessive inflammatory responses, and refractory hypoxemia. However, current therapeutic options are largely supportive; thus, it is of great interest to search for alternative agents to treat seawater aspiration-induced ALI. Erythropoietin (EPO) is a multifunctional agent with antiinflammatory, antioxidative, and antiapoptotic properties. However, the effects of EPO on seawater aspiration-induced ALI remain unclear. In the present study, male rats were randomly assigned to the naive group, normal saline group, seawater group, or seawater + EPO group. EPO was administered intraperitoneally at 48 and 24 h before seawater aspiration. Arterial blood gas analysis was performed with a gas analyzer at baseline, 30 min, 1 h, 4 h, and 24 h after seawater aspiration, respectively. Histological scores, computed tomography scan, nuclear factor kappa B p65, inducible nitric oxide synthase, caspase-3, tumor necrosis factor-alpha, interleukin (IL)-1β, IL-6, IL-10, wet-to-dry weight ratio, myeloperoxidase activity, malondialdehyde, and superoxide dismutase in the lung were determined 30 min after seawater aspiration. Our results showed that EPO pretreatment alleviated seawater aspiration-induced ALI, as indicated by increased arterial partial oxygen tension and decreased lung histological scores. Furthermore, EPO pretreatment attenuated seawater aspiration-induced increase in the expressions of pulmonary nuclear factor kappa B p65, inducible nitric oxide synthase, caspase-3, tumor necrosis factor-alpha, IL-1β, myeloperoxidase activity, and malondialdehyde when compared with the seawater group. Collectively, our study suggested that EPO pretreatment attenuates seawater aspiration-induced ALI by down-regulation of pulmonary pro-inflammatory cytokines, oxidative stress, and apoptosis.

  5. Extramedullary plasmacytoma. Fine needle aspiration findings.

    Science.gov (United States)

    Kumar, P V; Owji, S M; Talei, A R; Malekhusseini, S A

    1997-01-01

    To determine the role of fine needle aspiration cytology in the diagnosis of extramedullary plasmacytoma. The study group consisted of 13 patients with palpable masses at various sites. The tumors were aspirated for cytologic study. The smears revealed groups of mature and immature plasma cells at various stages of maturation. Mature plasma cells showed an eccentric nucleus and abundant, deep, basophilic cytoplasm with a paranuclear halo. Plasmablasts (immature plasma cells) showed a prominent, eccentric nucleus with single, large nucleolus and abundant, deep, basophilic cytoplasm with no paranuclear halo. Binucleate and multinucleate forms were also seen quite often. The tumors were excised, and the histologic sections confirmed the cytologic diagnosis. All the patients received radiotherapy. One patient (18 years old) developed recurrence and died due to extensive infiltration into the maxilla and mandible. Two patients (57 and 62 years) developed multiple myeloma one to two years after the excision of tumors, and both died two to three months later. The remaining 10 patients were alive and well at this writing. The smears from all 13 patients were diagnosed as extramedullary plasmacytomas by fine needle aspiration cytology.

  6. Diagnosis Of Thyroid Enlargement: Use Of Fine Needle Aspiration ...

    African Journals Online (AJOL)

    One hundred and ten Fine Needle Aspiration Biopsies (FNAC) obtained from 87 patients with thyroid enlargement or nodules were retrospectively reviewed. Aspiration biopsy was accomplished using 21-gauge needle attached with 20-ml plastic syringe. There were 14 males and 73 females involved in the study. Sixty- four ...

  7. Parental Influence on Mainland Chinese Children's Career Aspirations: Child and Parental Perspectives

    Science.gov (United States)

    Liu, Jianwei; McMahon, Mary; Watson, Mark

    2015-01-01

    Career aspirations developed in childhood may impact on future career development in adolescence and adulthood. Family is an important context in which children develop their career aspirations. This study examined how parents influence children's career aspirations in mainland China from both the parents' and children's perspectives. Eight…

  8. Training methods in non-destructive examination with ultrasonic testing

    International Nuclear Information System (INIS)

    Walte, F.

    1986-01-01

    German concept for inspection of LWR, leak before break, basic safety; General inspection methods; Ultrasonic inspection - basic principle, generation of ultrasound, bulk and surface waves, piezo electric and electromagnetic transducers, energy balance, scattering and adsorption, divergence; Ultra techniques in compliance with KTA-rules - pulse-echo, tandem, throughtransmission; Valuation of ultrasonic indications; Pre- and in-service inspection; Practical part - ultrasonic equipment, ultrasonic piezo electric transducers, wall thickness measurement, crack depth measurement with potential drop technique. (orig.)

  9. Ultrasonic Cleaning of Nuclear Steam Generator by Micro Bubble

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Woo Tae [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of); Kim, Sang Tae; Yoon, Sang Jung [Sae-An Engineering Co., Seoul (Korea, Republic of)

    2012-05-15

    In this paper, we present ultrasonic cleaning technology for a nuclear steam generator using micro bubble. We could extend the boundary of ultrasonic cleaning by using micro bubbles in water. Ultrasonic energy measured was increased about 5 times after the generation of micro bubbles in water. Furthermore, ultrasound energy was measured to be strong enough to create cavitation even though the ultrasound sensor was about 2 meters away from the ultrasonic transducer

  10. [Preoperative evaluation of surgery for intractable aspiration based on the prognostic nutritional index].

    Science.gov (United States)

    Uchida, Masaya; Hashimoto, Keiko; Mukudai, Shigeyuki; Ushijima, Chihisa; Dejima, Kenji

    2014-12-01

    Because there is no absolute indicator of the nutritional status and prognosis in patients with severe aspiration problems, it is quite difficult to arrive at a true long-time prognosis. By performing surgery for intractable aspiration on such patients, both the prognosis and QOL of the patients could be expected to improve. In our department, we have experienced patients dying within 6 months after surgery. In these cases, the patient's preoperative nutritional status was not good. Therefore, we consider that, when we adopt this procedure, there should be some indicators we should use which could have an effect on the prognosis of such nutritionally-challenged patients. In patients who underwent surgery for intractable aspiration; we examined the relationship between their survival and the prognostic nutritional index (PNI) which is an indicator of the risk of complications such as post-operative events in the surgical field. We investigated the relationship between the prognosis and the postoperative indicators of each of the following: WBC, CRP, serum albumin level, and PNI. Out of a total of 31 cases, the average O-PNI of eight cases in which death occurred was 29.45, and the average of six cases in which death occurred within 6 months after surgery was 28.26. The average O-PNI of the survivors was 36.01. A significant association was noted between the early postoperative deaths and some of the four indicators namely that serum albumin level and O-PNI. Based on the ROC curve, the O-PNI offered higher precision than the albumin level. The cut-off value of the O-PNI value for early postoperative mortality rate was 32. The early postoperative mortality rate was 44.4% in patients with less than 32 O-PNI in the preoperative examination, but if it were O-PNI 32 or more, the early postoperative mortality rate was 9.1%, significantly lower. Therefore, O-PNI could be useful as one of the prognostic evaluation factors in the case of preoperative surgery for intractable

  11. Ultrasonic inspection development at HEDL

    International Nuclear Information System (INIS)

    Day, C.K.; Mech, S.J.; Michaels, T.E.; Dixon, N.E.

    1978-01-01

    Ultrasonic testing methods and equipment are being developed to support preservice and in-service inspection of selected FFTF welds. A digital computer system is employed in the analysis of both simulated FFTF pipe sections and plate specimens containing fatigue cracks. It is anticipated that test evaluation standards containing fatigue cracks will partially eliminate questions formerly associated with weld test calibration producers by providing natural cracks which follow grain boundaries and stress patterns resembling piping situ conditions. Studies have revealed that commercial transducers may satisfy LMFBR ultrasonic pipe inspection applications: The test system evaluation included transducers and wedge coupling and fluid coupling materials which exhibited acceptable performance at temperatures to 2300C. Results are presented that demonstrate the feasibility of ultrasonic inspection of components immersed in sodium at temperatures to 2600C. (UK)

  12. Effect of decision making on ultrasonic examination performance

    International Nuclear Information System (INIS)

    Harris, D.H.

    1992-05-01

    A decision aid was developed to overcome examiner limitations in information processing and decision making during ultrasonic examinations. The aid provided a means of noting signal characteristics as they were observed during the examination, and of presenting them simultaneously for decision making. The aid also served as a way of providing detailed feedback on examination performance during training. The aid was incorporated into worksheets used for the conduct of practice examinations during ultrasonic examination training. To support the introduction and use of the decision aid, one hour of supplementary training was inserted in an existing 64-hour training course on ultrasonic detection of defects. This study represented a modest step in improving the performance of ultrasonic examinations in nuclear power plants. Findings indicated that aided decision making supported by limited training can significantly improve ultrasonic detection performance

  13. Induction of parotitis by fine-needle aspiration in parotid Warthin's tumor.

    Science.gov (United States)

    Suzuki, Kensuke; Iwai, Hiroshi; Kaneko, Toshihiko; Sakaguchi, Mariko; Hoshino, Shoichi; Inaba, Muneo

    2009-08-01

    To estimate parotitis caused by fine-needle aspiration (FNA) in parotid Warthin tumor. Case series with chart review. Hospital records were reviewed for 104 parotid tumors (103 patients) including 35 Warthin tumors, which underwent FNA within our department. Three patients with four Warthin tumors among them noticed parotid pain, swelling, and abscess formation as a consequence of acute parotitis after FNA. Examinations of the materials obtained from tumor puncture or drainage before the start of antibiotic therapy showed no bacterial association in any patient. Two of the patients with Warthin tumor underwent parotidectomy, and the surgical specimens indicated histopathological changes with necrosis, abscess, granuloma, and the infiltration of inflammatory cells including Langhans-type multinucleated giant cells. It is conceivable that Warthin tumor bears the characteristics of inflammation induced by the FNA procedure without any relation to infection. Therefore, it may be better to avoid routine FNA and give priority to diagnostic imagings over FNA in the diagnosis of tumors strongly suspected as Warthin tumor.

  14. Aspiration of human neutrophils: effects of shear thinning and cortical dissipation.

    Science.gov (United States)

    Drury, J L; Dembo, M

    2001-12-01

    It is generally accepted that the human neutrophil can be mechanically represented as a droplet of polymeric fluid enclosed by some sort of thin slippery viscoelastic cortex. Many questions remain however about the detailed rheology and chemistry of the interior fluid and the cortex. To address these quantitative issues, we have used a finite element method to simulate the dynamics of neutrophils during micropipet aspiration using various plausible assumptions. The results were then systematically compared with aspiration experiments conducted at eight different combinations of pipet size and pressure. Models in which the cytoplasm was represented by a simple Newtonian fluid (i.e., models without shear thinning) were grossly incapable of accounting for the effects of pressure on the general time scale of neutrophil aspiration. Likewise, models in which the cortex was purely elastic (i.e., models without surface viscosity) were unable to explain the effects of pipet size on the general aspiration rate. Such models also failed to explain the rapid acceleration of the aspiration rate during the final phase of aspiration nor could they account for the geometry of the neutrophil during various phases of aspiration. Thus, our results indicate that a minimal mechanical model of the neutrophil needs to incorporate both shear thinning and surface viscosity to remain valid over a reasonable range of conditions. At low shear rates, the surface dilatation viscosity of the neutrophil was found to be on the order of 100 poise-cm, whereas the viscosity of the interior cytoplasm was on the order of 1000 poise. Both the surface viscosity and the interior viscosity seem to decrease in a similar fashion when the shear rate exceeds approximately 0.05 s(-1). Unfortunately, even models with both surface viscosity and shear thinning studied are still not sufficient to fully explain all the features of neutrophil aspiration. In particular, the very high rate of aspiration during the

  15. Short Lingual Osteotomy Using a Piezosurgery Ultrasonic Bone-Cutting Device During Sagittal Split Ramus Osteotomy.

    Science.gov (United States)

    Kawase-Koga, Yoko; Mori, Yoshiyuki; Kanno, Yuki; Hoshi, Kazuto; Takato, Tsuyoshi

    2015-10-01

    Short lingual osteotomy is a useful method for the performance of sagittal split ramus osteotomy involving interference between the proximal and distal bone fragments when lateral differences exist in the setback distance. However, this procedure occasionally results in abnormal fracture and nerve injury; expert surgical skill is thus required. We herein describe a novel technique involving the use of an ultrasonic bone-cutting device (Piezosurgery; Mectron Medical Technology, Carasco, Italy) for vertical osteotomy posterior to the mandibular foramen. Successful short lingual osteotomy was performed using this technique with avoidance of abnormal fracture and neurovascular bundle damage.

  16. Students' Aspirations, Expectations and School Achievement: What Really Matters?

    Science.gov (United States)

    Khattab, Nabil

    2015-01-01

    Using the Longitudinal Study of Young People in England (LSYPE), this study examines how different combinations of aspirations, expectations and school achievement can influence students' future educational behaviour (applying to university at the age of 17-18). The study shows that students with either high aspirations or high expectations have…

  17. Aspiration pneumonia induces muscle atrophy in the respiratory, skeletal, and swallowing systems.

    Science.gov (United States)

    Komatsu, Riyo; Okazaki, Tatsuma; Ebihara, Satoru; Kobayashi, Makoto; Tsukita, Yoko; Nihei, Mayumi; Sugiura, Hisatoshi; Niu, Kaijun; Ebihara, Takae; Ichinose, Masakazu

    2018-05-22

    Repetition of the onset of aspiration pneumonia in aged patients is common and causes chronic inflammation. The inflammation induces proinflammatory cytokine production and atrophy in the muscles. The proinflammatory cytokines induce muscle proteolysis by activating calpains and caspase-3, followed by further degradation by the ubiquitin-proteasome system. Autophagy is another pathway of muscle atrophy. However, little is known about the relationship between aspiration pneumonia and muscle. For swallowing muscles, it is not clear whether they produce cytokines. The main objective of this study was to determine whether aspiration pneumonia induces muscle atrophy in the respiratory (the diaphragm), skeletal (the tibialis anterior, TA), and swallowing (the tongue) systems, and their possible mechanisms. We employed a mouse aspiration pneumonia model and computed tomography (CT) scans of aged pneumonia patients. To induce aspiration pneumonia, mice were inoculated with low dose pepsin and lipopolysaccharide solution intra-nasally 5 days a week. The diaphragm, TA, and tongue were isolated, and total RNA, proteins, and frozen sections were stored. Quantitative real-time polymerase chain reaction determined the expression levels of proinflammatory cytokines, muscle E3 ubiquitin ligases, and autophagy related genes. Western blot analysis determined the activation of the muscle proteolysis pathway. Frozen sections determined the presence of muscle atrophy. CT scans were used to evaluate the muscle atrophy in aged aspiration pneumonia patients. The aspiration challenge enhanced the expression levels of proinflammatory cytokines in the diaphragm, TA, and tongue. Among muscle proteolysis pathways, the aspiration challenge activated caspase-3 in all the three muscles examined, whereas calpains were activated in the diaphragm and the TA but not in the tongue. Activation of the ubiquitin-proteasome system was detected in all the three muscles examined. The aspiration challenge

  18. The prevalence and effects of aspiration among neonates at the time of discharge.

    Science.gov (United States)

    Karsch, Emily; Irving, Sharon Y; Aylward, Brandon S; Mahle, William T

    2017-09-01

    Neonates undergoing heart surgery for CHD are at risk for postoperative gastrointestinal complications and aspiration events. There are limited data regarding the prevalence of aspiration after neonatal cardiothoracic surgery; thus, the effects of aspiration events on this patient population are not well understood. This retrospective chart review examined the prevalence and effects of aspiration among neonates who had undergone cardiac surgery at the time of their discharge. Introduction This study examined the prevalence of aspiration among neonates who had undergone cardiac surgery. Demographic data regarding these patients were analysed in order to determine risk factors for postoperative aspiration. Post-discharge feeding routes and therapeutic interventions were extracted to examine the time spent using alternate feeding routes because of aspiration risk or poor caloric intake. Modified barium swallow study results were used to evaluate the effectiveness of the test as a diagnostic tool. Materials and methods A retrospective study was undertaken of neonates who had undergone heart surgery from July, 2013 to January, 2014. Data describing patient demographics, feeding methods, and follow-up visits were recorded and compared using a χ2 test for goodness of fit and a Kaplan-Meier graph. The patient population included 62 infants - 36 of whom were male, and 10 who were born with single-ventricle circulation. The median age at surgery was 6 days (interquartile range=4 to 10 days). Modified barium swallow study results showed that 46% of patients (n=29) aspirated or were at risk for aspiration, as indicated by laryngeal penetration. In addition, 48% (n=10) of subjects with a negative barium swallow or no swallow study demonstrated clinical aspiration events. Tube feedings were required by 66% (n=41) of the participants. The median time spent on tube feeds, whether in combination with oral feeds or exclusive use of a nasogastric or gastric tube, was 54 days; 44% (n

  19. Cervical Hyperostosis Leading to Dyspnea, Aspiration and Dysphagia: Strategies to Improve Patient Management

    Directory of Open Access Journals (Sweden)

    Georgios Psychogios

    2018-04-01

    Full Text Available Diffuse idiopathic skeletal hyperostosis (DISH is a rare but well known cause of dysphagia. In very few cases aspiration and dyspnea are described as a clinical manifestation. An 82-year-old man presented himself in our clinic with severe dyspnea, aspiration, and pneumonia. After performing a microlaryngoscopy an emergency tracheotomy became necessary.In laryngoscopy a severe bulging of the posterior oropharyngeal and hypopharyngeal wall was detected. The glottis area was not observable and immobilisation of the right vocal cord could be detected. The CT showed anterior osteophytes and ossification of the anterior longitudinal ligament from C2–C7. We performed a panendoscopy in order to explore the upper aerodigestive area. Postoperatively an emergency tracheotomy was needed due to the development of laryngeal edema. The osteophytes were removed in cooperation with the department of orthopaedics. Three months postoperative the patient had no dyspnea or dysphagia, so the tracheotomy could be closed.Cervical hyperostosis is commonly described in elderly patients and usually presenting without symptoms, therefore a surgical treatment is usually not necessary. Nevertheless it can lead to severe morbidity and dyspnea with airway obstruction. Therefore it is essential that cervical hyperostosis is recognized early enough and appropriate treatment is initiated. Flexible endoscopy should be preferred over direct panendoscopy because it could lead to life-threatening edema and a prophylactic tracheostomy should be strongly considered in patients that present with severe dyspnea,

  20. Topical topic: value of fine needle aspiration biopsy in childhood rhabdomyosarcoma: twenty-six years of experience in Slovenia.

    Science.gov (United States)

    Pohar-Marinsek, Ziva; Anzic, Jozica; Jereb, Berta

    2002-06-01

    Chemotherapy (Cht) for rhabdomyosarcoma (RMS) given before local treatment can prevent mutilating surgery and high-dose irradiation (RT). Fine needle aspiration biopsy (FNAB) can confirm the diagnosis and neoadjuvant treatment can start without delay. The purpose of our study was to assess the role of FNAB in the management of childhood RMS in Slovenia. A total of 78 children and young adults were included. FNAB provided the pre-treatment diagnosis in 37 and surgical biopsy in 41 patients. In 61 cases recurrent/metastatic disease was aspirated. Cytological diagnoses were compared to the original histological diagnoses. All case histories, cytological and histological material were reviewed and immunocytochemical staining performed when necessary. FNAB provided a correct diagnosis of malignancy in all 37 primary tumours, a specific diagnosis of RMS was given in 29 (78%). With the use of immunocytochemistry during the last 15 years, the accuracy has risen to 87%. FNAB provided the diagnosis of recurrence/metastasis in 57/61 cases. No complications of FNAB were noted. Review of histology reclassified five original diagnoses of RMS into one malignant rhabdoid tumour and four sarcomas NOS. In review of cytology we were able to sub classify 80% of RMS. FNAB is a safe method, which enables us to establish the pre-treatment diagnosis of RMS, and to some extent even its type, without delay. In our study, FNAB successfully replaced surgical biopsy in 87% of RMS patients during the last 15 years. Neoadjuvant Cht was started immediately, surgery was delayed and more conservative. Consequently, the risk for treatment sequelae was considerably reduced. Copyright 2002 Wiley-Liss, Inc.

  1. On-line ultrasonic gas entrainment monitor

    International Nuclear Information System (INIS)

    Day, C.K.; Pedersen, H.N.

    1978-01-01

    Apparatus employing ultrasonic energy for detecting and measuring the quantity of gas bubbles present in liquids being transported through pipes is described. An ultrasonic transducer is positioned along the longitudinal axis of a fluid duct, oriented to transmit acoustic energy radially of the duct around the circumference of the enclosure walls. The back-reflected energy is received centrally of the duct and interpreted as a measure of gas entrainment. One embodiment employs a conical reflector to direct the transmitted acoustic energy radially of the duct and redirect the reflected energy back to the transducer for reception. A modified embodiment employs a cylindrical ultrasonic transducer for this purpose

  2. Turban pin aspiration: new fashion, new syndrome.

    Science.gov (United States)

    Ilan, Ophir; Eliashar, Ron; Hirshoren, Nir; Hamdan, Kasem; Gross, Menachem

    2012-04-01

    Turban pin aspiration syndrome is a new clinical entity afflicting young Islamic girls wearing a turban.The goal of this study was to present our experience in diagnosis and treatment of this new entity, define its clinical and epidemiologic features, and shed a new light on the role of fashion in the increased incidence. A retrospective study in a tertiary university hospital. Review of clinical parameters and epidemiologic features of 26 patients diagnosed with turban pin aspiration syndrome admitted to the Hadassah-Hebrew University Hospitals in Jerusalem from 1990 to 2010. All patients were Muslim females with an average age of 16 years. In all cases, the history was positive for accidental aspiration. Most of the pins were located in the trachea (42%). In 20 cases, the pins were extracted by rigid bronchoscopy without major complications. Fluoroscopy-assisted rigid bronchoscopy was used successfully in three cases. In one case, the object was self-ejected by coughing before the bronchoscopy, and two patients were referred to the chest unit for thoracotomy. Clinicians should be aware of this distinct form of foreign body aspiration, its method of diagnosis, and extraction techniques. A cultural investigation showed a difference in the turban-fastening technique of young girls as compared with their mothers. Removal by rigid bronchoscopy is a safe method with a high success rate and should be considered as the preferred extraction method of choice. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  3. Mechanochemical degradation of potato starch paste under ultrasonic irradiation

    Institute of Scientific and Technical Information of China (English)

    LI Jian-bin; LI Lin; LI Bing; CHEN Ling; GUI Lin

    2006-01-01

    In the paper, changes in the molecular weight, the intrinsic viscosity and the polydispersity (molecular mass distribution) of treated potato starch paste were studied under different ultrasonic conditions which include irradiation time, ultrasonic intensity, potato starch paste concentration, and distance from probe tip on the degradation of potato starch paste. Intrinsic viscosity of potato starch paste was determined following the ASTM (American Society for Testing and Materials) standard practice for dilute solution viscosity of polymers. Molecular mass and polydispersity of potato starch paste were measured on GPC (Gel Permeation Chromatography). The results showed that the average molecular mass and the intrinsic viscosity of starch strongly depended on irradiation time. Degradation increased with prolonged ultrasonic irradiation time, and the increase of ultrasonic intensity could accelerate the degradation, resulting in a faster degradation rate, a lower limiting value and a higher degradation extent. Starch samples were degraded faster in dilute solutions than in concentrated solutions. The molecular mass and the intrinsic viscosity of starch increased with the increase of distance from probe tip. Our results also showed that the polydispersity decreased with ultrasonic irradiation under all ultrasonic conditions. Ultrasonic degradation of potato starch paste occured based on the mechanism of molecular relaxation of starch paste. In the initial stage, ultrasonic degradation of potato starch paste was a random process, and the molecular mass distribution was broad. After that, ultrasonic degradation of potato starch paste changed to a nonrandom process, and the molecular mass distribution became narrower. Finally, molecular mass distribution tended toward a saturation value.

  4. A flow meter for ultrasonically measuring the flow velocity of fluids

    DEFF Research Database (Denmark)

    2015-01-01

    The invention regards a flow meter for ultrasonically measuring the flow velocity of fluids comprising a duct having a flow channel with an internal cross section comprising variation configured to generate at least one acoustic resonance within the flow channel for a specific ultrasonic frequency......, and at least two transducers for generating and sensing ultrasonic pulses, configured to transmit ultrasonic pulses at least at said specific ultrasonic frequency into the flow channel such that the ultrasonic pulses propagate through a fluid flowing in the flow channel, wherein the flow meter is configured...

  5. Bulk viscosity and ultrasonic attenuation in liquid metals

    International Nuclear Information System (INIS)

    Awasthi, O.N.; Murthy, B.V.S.

    1984-11-01

    Ultrasonic attenuation in simple liquid metals has been investigated using the thermodynamic theory of relaxation processes incorporating the concept of a two state model for the liquid near the melting point. Agreement of the results with the experimental values of the ultrasonic attenuation and bulk viscosity indicates that this might be an appropriate approach to explain the excess attenuation of ultrasonic waves in liquid metals. (author)

  6. Individual-Level Predictors of Young Children's Aspirations

    Science.gov (United States)

    Moulton, Vanessa; Flouri, Eirini; Joshi, Heather; Sullivan, Alice

    2018-01-01

    Often young children already have some ideas about what they want to do in the future. Using data from a large UK cohort study, we investigated the individual determinants of seven-year-old children's aspirations, controlling for parental socio-economic background and parental involvement in learning. At age 7, not all children's aspirations were…

  7. Diagnostic accuracy of lymphoma established by fine-needle aspiration cytological biopsy

    Science.gov (United States)

    Delyuzar; Amir, Z.; Suryadi, D.

    2018-03-01

    Based on Globocan data in 2012, it is estimated that about 14,495 Indonesians suffer from lymphoma, both Hodgkin’s lymphoma, and non-Hodgkin’s lymphoma. Some areas of specialization still doubt the accuracy of cytology diagnosis of fine needle aspiration biopsy.This study is a diagnostic test with a cross sectional analytic design to see how the cytology diagnostic accuracy of fine needle aspiration aspirate in lymphoma. It was in Department of Anatomical Pathology Faculty of Medicine USU, Haji Adam Malik Hospital, Dr.Pirngadi hospital, or private clinic in Medan. Peripheral cytology technique biopsy of fine needle aspiration on lymph node subsequently stained with Giemsa, when the cytology of lymphoma is obtained and confirmed by histopathologic examination. Cytology and histopathologic examination will be tested by Diagnostic Test and assessed for its sensitivity and specificity. The diagnostic of lymphoma cytology provides 93.33% sensitivity and 92.31% specificity when confirmed by histopathological examination. Positive predictive value and negative predictive value of 96.55% and 85.71% respectively. In conclusion, the cytology of fine needle aspiration biopsy is accurate enough to be used as a diagnostic tool, so it is advisable to establish a lymphoma diagnosis to perform a needle aspiration biopsy examination.

  8. Ultrasonic techniques for fluids characterization

    CERN Document Server

    Povey, Malcolm J W

    1997-01-01

    This book is a comprehensive and practical guide to the use of ultrasonic techniques for the characterization of fluids. Focusing on ultrasonic velocimetry, the author covers the basic topics and techniques necessaryfor successful ultrasound measurements on emulsions, dispersions, multiphase media, and viscoelastic/viscoplastic materials. Advanced techniques such as scattering, particle sizing, and automation are also presented. As a handbook for industrial and scientific use, Ultrasonic Techniques for Fluids Characterization is an indispensable guide to chemists and chemical engineers using ultrasound for research or process monitoring in the chemical, food processing, pharmaceutical, cosmetic, biotechnology,and fuels industries. Key Features * Appeals to anyone using ultrasound to study fluids * Provides the first detailed description of the ultrasound profiling technique for dispersions * Describes new techniques for measuring phase transitions and nucleation, such as water/ice and oil/fat * Presents the l...

  9. Cement-based materials' characterization using ultrasonic attenuation

    Science.gov (United States)

    Punurai, Wonsiri

    The quantitative nondestructive evaluation (NDE) of cement-based materials is a critical area of research that is leading to advances in the health monitoring and condition assessment of the civil infrastructure. Ultrasonic NDE has been implemented with varying levels of success to characterize cement-based materials with complex microstructure and damage. A major issue with the application of ultrasonic techniques to characterize cement-based materials is their inherent inhomogeneity at multiple length scales. Ultrasonic waves propagating in these materials exhibit a high degree of attenuation losses, making quantitative interpretations difficult. Physically, these attenuation losses are a combination of internal friction in a viscoelastic material (ultrasonic absorption), and the scattering losses due to the material heterogeneity. The objective of this research is to use ultrasonic attenuation to characterize the microstructure of heterogeneous cement-based materials. The study considers a real, but simplified cement-based material, cement paste---a common bonding matrix of all cement-based composites. Cement paste consists of Portland cement and water but does not include aggregates. First, this research presents the findings of a theoretical study that uses a set of existing acoustics models to quantify the scattered ultrasonic wavefield from a known distribution of entrained air voids. These attenuation results are then coupled with experimental measurements to develop an inversion procedure that directly predicts the size and volume fraction of entrained air voids in a cement paste specimen. Optical studies verify the accuracy of the proposed inversion scheme. These results demonstrate the effectiveness of using attenuation to measure the average size, volume fraction of entrained air voids and the existence of additional larger entrapped air voids in hardened cement paste. Finally, coherent and diffuse ultrasonic waves are used to develop a direct

  10. Surgical repair of a pseudoaneurysm of the ascending aorta after aortic valve replacement

    Directory of Open Access Journals (Sweden)

    Almeida Rui Manuel Sequeira de

    2001-01-01

    Full Text Available We report the case of a patient with a pseudoaneurysm of the ascending aortic clinically diagnosed 5 months after surgical replacement of the aortic valve. Diagnosis was confirmed with the aid of two-dimensional echocardiography and helicoidal angiotomography. The corrective surgery, which consisted of a reinforced suture of the communication with the ascending aorta after opening and aspiration of the cavity of the pseudoaneurysm, was successfully performed through a complete sternotomy using extracorporeal circulation, femorofemoral cannulation, and moderate hypothermia, with no aortic clamping.

  11. Minimally Invasive Surgical Treatment of Acute Epidural Hematoma: Case Series

    Directory of Open Access Journals (Sweden)

    Weijun Wang

    2016-01-01

    Full Text Available Background and Objective. Although minimally invasive surgical treatment of acute epidural hematoma attracts increasing attention, no generalized indications for the surgery have been adopted. This study aimed to evaluate the effects of minimally invasive surgery in acute epidural hematoma with various hematoma volumes. Methods. Minimally invasive puncture and aspiration surgery were performed in 59 cases of acute epidural hematoma with various hematoma volumes (13–145 mL; postoperative follow-up was 3 months. Clinical data, including surgical trauma, surgery time, complications, and outcome of hematoma drainage, recovery, and Barthel index scores, were assessed, as well as treatment outcome. Results. Surgical trauma was minimal and surgery time was short (10–20 minutes; no anesthesia accidents or surgical complications occurred. Two patients died. Drainage was completed within 7 days in the remaining 57 cases. Barthel index scores of ADL were ≤40 (n=1, 41–60 (n=1, and >60 (n=55; scores of 100 were obtained in 48 cases, with no dysfunctions. Conclusion. Satisfactory results can be achieved with minimally invasive surgery in treating acute epidural hematoma with hematoma volumes ranging from 13 to 145 mL. For patients with hematoma volume >50 mL and even cerebral herniation, flexible application of minimally invasive surgery would help improve treatment efficacy.

  12. Coevolution of aspirations and cooperation in spatial prisoner's dilemma game

    International Nuclear Information System (INIS)

    Chen, Wei; Wu, Te; Li, Zhiwu; Wang, Long

    2015-01-01

    Suboptimal outcomes are often more acceptable than the best ones when the latter are hard or even impossible to find. In order to describe the emergence of cooperation when suboptimal alternatives prevail, an evolutionary game model is established by considering the effects of aspirations. A win-stay-lose-shift like rule for strategy updating is proposed. The rule prescribes that if the payoff of the current strategy is greater than the aspiration, the strategy remains, otherwise the strategy changes. Aspiration updating allows for individuals to adjust their expected payoff levels. It is shown that suboptimal alternatives can promote the emergence and persistence of cooperation over a wide range of the temptation to defect. Furthermore, a nontrivial phenomenon is found that cooperators prevail as the temptation increases when it is small. The aspirations are stabilized at an intermediate level which can most facilitate cooperation. The obtained results also show that the average level of aspirations decreases as the temptation increases. Furthermore, the variance of aspiration levels is minimized for an intermediate level of temptation. (paper)

  13. Radiographic-guided fine-needle aspiration of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Helvie, M.A.; Baker, D.E.; Adler, D.D.; Andersson, I.; Naylor, B.; Buckwalter, K.

    1989-01-01

    The authors have performed radiographically guided fine-needle aspirations (FNA) on 215 nonpalpable mammographically detected breast lesions, using a coordinate grid localization system. Aspirates were classified into five cytologic groups. With the most stringent cytologic criteria, the sensitivity was 98% and the specificity 95% for the detection of carcinoma. However, according to these strict cytologic criteria, only 46% of aspirates contained representative material. Forty-two of 74 lesions undergoing biopsy proved malignant. Sixteen percent of patients did not compete adequate mammographic follow-up. High sensitivity and specificity can be achieved with radiographically guided FNA. However, management decisions ultimately require integration of mammographic findings with cytologic results. Close cooperation between mammographer, surgeon, cytopathologist, and patients is mandatory for successful operation

  14. Aspiration biopsy of testis: another method for histologic examination

    International Nuclear Information System (INIS)

    Nseyo, U.O.; Englander, L.S.; Huben, R.P.; Pontes, J.E.

    1984-01-01

    The most important method for evaluating the pathogenesis of male infertility is open testicular biopsy. Herein the authors describe a method of aspiration biopsy of testis for histologic examination. Sexually mature dogs and rats treated with chemotherapeutic agents and ionizing radiation were followed with periodic testicular aspiration biopsy during and after treatment. The histologic findings from the aspiration biopsy compare with the results of routine histologic examination in assessing spermatogenetic activity and delineating pathologic changes. The puncture in the experimental animals was performed under general anesthesia. In human patients testicular biopsy could be done under local anesthesia in an outpatient clinic. The procedure would be less painful, minimally invasive, and more cost-effective

  15. Beat-Frequency/Microsphere Medical Ultrasonic Imaging

    Science.gov (United States)

    Yost, William T.; Cantrell, John H.; Pretlow, Robert A., III

    1995-01-01

    Medical ultrasonic imaging system designed to provide quantitative data on various flows of blood in chambers, blood vessels, muscles, and tissues of heart. Sensitive enough to yield readings on flows of blood in heart even when microspheres used as ultrasonic contrast agents injected far from heart and diluted by circulation of blood elsewhere in body.

  16. Ultrasonic sensor for sodium perspective device

    International Nuclear Information System (INIS)

    Ogawa, Fujio; Onuki, Koji.

    1995-01-01

    The present invention concerns an ultrasonic wave sensor for a sodium perspective device disposed in an FBR type reactor, which can change the directing angle of the ultrasonic sensor irrespective of the external conditions in liquid sodium. Namely, the sensor comprises (1) a sensor main body, (2) a diaphragm disposed on an oscillating surface of ultrasonic waves generated from the sensor main body, (3) a pressurizing and depressurizing nozzle connected to the sensor main body, and (4) a pressure detector disposed to these nozzles. A gas is charged/discharged to and from the sensor main body to control a gas pressure in the main body. If the gas pressure is made higher, the diaphragm is deformed convexly. If the gas pressure is lowered, the diaphragm is deformed concavely. The directing angle is greater when it is deformed a convexly, and it is smaller when it is deformed concavely. Accordingly, ultrasonic wave receiving/sending range in the sodium can be varied optionally by controlling the gas pressure in the main body. (I.S.)

  17. Designing an in-situ ultrasonic nondestructive evaluation system for ultrasonic additive manufacturing

    Science.gov (United States)

    Nadimpalli, Venkata K.; Nagy, Peter B.

    2018-04-01

    Ultrasonic Additive Manufacturing (UAM) is a solid-state layer by layer manufacturing process that utilizes vibration induced plastic deformation to form a metallurgical bond between a thin layer and an existing base structure. Due to the vibration based bonding mechanism, the quality of components at each layer depends on the geometry of the structure. In-situ monitoring during and between UAM manufacturing steps offers the potential for closed-loop control to optimize process parameters and to repair existing defects. One interface that is most prone to delamination is the base/build interface and often UAM component height and quality are limited by failure at the base/build interface. Low manufacturing temperatures and favorable orientation of typical interface defects in UAM make ultrasonic NDE an attractive candidate for online monitoring. Two approaches for in-situ NDE are discussed and the design of the monitoring system optimized so that the quality of UAM components is not affected by the addition of the NDE setup. Preliminary results from in-situ ultrasonic NDE indicate the potential to be utilized for online qualification, closed-loop control and offline certification of UAM components.

  18. Computer simulation of ultrasonic waves in solids

    International Nuclear Information System (INIS)

    Thibault, G.A.; Chaplin, K.

    1992-01-01

    A computer model that simulates the propagation of ultrasonic waves has been developed at AECL Research, Chalk River Laboratories. This program is called EWE, short for Elastic Wave Equations, the mathematics governing the propagation of ultrasonic waves. This report contains a brief summary of the use of ultrasonic waves in non-destructive testing techniques, a discussion of the EWE simulation code explaining the implementation of the equations and the types of output received from the model, and an example simulation showing the abilities of the model. (author). 2 refs., 2 figs

  19. Ultrasonic Transducer Peak-to-Peak Optical Measurement

    Directory of Open Access Journals (Sweden)

    Pavel Skarvada

    2012-01-01

    Full Text Available Possible optical setups for measurement of the peak-to-peak value of an ultrasonic transducer are described in this work. The Michelson interferometer with the calibrated nanopositioner in reference path and laser Doppler vibrometer were used for the basic measurement of vibration displacement. Langevin type of ultrasonic transducer is used for the purposes of Electro-Ultrasonic Nonlinear Spectroscopy (EUNS. Parameters of produced mechanical vibration have to been well known for EUNS. Moreover, a monitoring of mechanical vibration frequency shift with a mass load and sample-transducer coupling is important for EUNS measurement.

  20. Cognitive Correlates of Adolescents' Aspirations to Leadership: A Developmental Study.

    Science.gov (United States)

    Singer, Ming

    1990-01-01

    Examined age and gender differences in leadership aspirations among adolescents (N=130) by measuring overall leadership aspirations, valence-instrumentality expectancies for leadership outcomes, self-efficacy perceptions, and attributions of effective leadership. Found significant gender differences in valence scores and age differences in…

  1. Determine bond strength by ultrasonic measurement

    International Nuclear Information System (INIS)

    Brown, C.M.

    1978-01-01

    Application of ultrasonic methods for the evaluation and measurement of bond strength has been the object of numerous investigations in the last fifteen years. Some investigators have reported good success (in limited application) while others have experienced dismal failure. One problem common to all investigations was the difficulty in extracting and isolating the many components which comprise the ultrasonic signal reflected from a bonded interface. Part of this problem was due to manually extracting individual parameters from large volumes of raw data. However, with the vast technology now available in the field of signal analysis and computerized data processing, it is feasible to isolate and analyze individual parameters within the ultrasonic signal for great volumes of raw data

  2. Numerical shaping of the ultrasonic wavelet

    International Nuclear Information System (INIS)

    Bonis, M.

    1991-01-01

    Improving the performance and the quality of ultrasonic testing requires the numerical control of the shape of the driving signal applied to the piezoelectric transducer. This allows precise shaping of the ultrasonic field wavelet and corrections for the physical defects of the transducer, which are mainly due to the damper or the lens. It also does away with the need for an accurate electric matching. It then becomes feasible to characterize, a priori, the ultrasonic wavelet by means of temporal and/or spectral specifications and to use, subsequently, an adaptative algorithm to calculate the corresponding driving wavelet. Moreover, the versatility resulting from the numerical control of this wavelet allows it to be changed in real time during a test

  3. Endoscopic ultrasound with fine needle aspiration and biopsy in lung cancer and isolated mediastinal lymphadenopathy.

    LENUS (Irish Health Repository)

    Nadarajan, P

    2010-03-01

    Endoscopic ultrasound with fine-needle aspiration and biopsy (EUS-FNAB) is well established in diagnosing and staging lung cancer in patients with mediastinal adenopathy. EUS-FNAB is highly sensitive, less invasive and has lower complication rates when compared to surgical staging of mediastinal nodes. In this study we describe our experience of EUS-FNAB in lung cancer and other causes of mediastinal lymphadenopathy. EUS-FNAB was performed for assessment of PET positive mediastinal lymph nodes between January 2007 and March 2009 in AMNCH. The endpoints of our study were sensitivity and specificity of EUS-FNAB, morbidity and length of hospital stay. Thirty four patients underwent EUS-FNAB during the study period for both diagnosis and staging. Thirty patients had positive lymph node invasion and 4 had no evidence of malignant invasion. In these 4 patients negative cytology was confirmed on mediastinoscopy giving EUS-FNAB a sensitivity and specificity of 100%. EUS-FNAB upstaged the disease in 12 patients. EUS-FNAB is a reliable tool for mediastinal staging in lung cancer, significantly reducing the need for surgical staging procedures in patients with suspected mediastinal involvement.

  4. Detection of blood aspiration in deadly head gunshots comparing postmortem computed tomography (PMCT) and autopsy.

    Science.gov (United States)

    Scaparra, E; Peschel, O; Kirchhoff, C; Reiser, M; Kirchhoff, S M

    2016-11-01

    The aim of our study was to analyze the reliability of postmortem computed tomography (PMCT) versus autopsy in detecting signs of blood aspiration in a distinct group of patients following deadly head, mouth or floor of mouth gunshot injuries. In this study, in 41 cases PMCT was compared to autopsy reports, the gold standard of postmortem exams, regarding detection of blood aspiration. PMCT was evaluated for the presence and level of typical signs of blood aspiration in the major airways and lung using a semi-quantitative scale ranging from level 0 (no aspiration) to 3 (significant aspiration) also taking density values of the described potential aspiratory changes into account. Overall, in 29 (70.7%) of 41 enrolled cases PMCT and autopsy revealed the same level of aspiration. A difference of one level between PMCT and autopsy resulted for 5 (12.2%) of the remaining 12 cases. More than one level difference between both methods resulted for 7 cases (17.2%). Autopsy described no signs of aspiration in 10 cases, compared to 31 cases with reported blood aspiration. In contrast, PMCT revealed no signs of blood aspiration in 15 cases whereas 26 cases were rated as positive for signs of aspiration in the major airways. In 18 of these 26 cases considered positive for blood aspiration by autopsy and PMCT, clear signs of aspiration signs were also described bilaterally by both methods. The presented study provides evidence for the assumption that PMCT seems to be helpful in the detection of blood aspiration in cases of deadly head gunshots. In conclusion, it seems reasonable to suggest performing PMCT additionally to traditional postmortem exams in cases of suspected aspiration to rule out false-negative cases and to possibly allow for a more detailed and rather evidence based examination reconnoitering the cause of death. However, the adequate use of PMCT in this context needs further evaluation and the definition of an objective scale for aspiration detection on PMCT needs

  5. Review of ultrasonic irrigation in endodontics: increasing action of irrigating solutions

    Science.gov (United States)

    Mozo, Sandra; Llena, Carmen

    2012-01-01

    Introduction: Effective irrigant delivery and agitation are prerequisites for successful endodontic treatment. Ultrasonic irrigation can be performed with or without simultaneous ultrasonic instrumentation. Existing literature reveals that ultrasonic irrigation may have a very positive effect on chemical, biological and physical debridement of the root canal system as investigated in many in vitro studies. Objective: The purpose of this review article was to summarize and discuss the available information concerning ultrasonic irrigation in endodontics. Methods: This article presents an overview of ultrasonic irrigation methods and their debridement efficacy. In this paper the relevant literature on passive ultrasonic irrigation is reviewed. Information from original scientific papers or reviews listed in MEDLINE and Cochrane were included in the review. Results: The use of ultrasound in the irrigation procedure results in improved canal cleanliness, better irrigant transfer to the canal system, soft tissue debridement, and removal of smear layer and bacteria. There are many in vitro studies, but there is a need to standardize protocols, and correlate the clinical efficacy of ultrasonic devices with improved treatment outcomes. Understanding the basis of ultrasonic irrigation is fundamental for clinicians and researchers to improve the design and use of ultrasonic irrigation. Key words:Ultrasonic irrigation, ultrasound, smear layer, endodontics. PMID:22143738

  6. Perioperative pulmonary aspiration is infrequent and low risk in pediatric anesthetic practice.

    Science.gov (United States)

    Kelly, Christopher J; Walker, Robert W M

    2015-01-01

    Recent studies have reported perioperative pulmonary aspiration in pediatric practice to be an uncommon problem associated with low morbidity and mortality. This paper examines the recent publications in both the adult and pediatric literature and looks at some of the potential risk factors involved, both patient and anesthetic, in the development of aspiration of gastric contents. We also look at the risk of severe morbidity following pulmonary aspiration and speculate on possible reasons behind the assertion that pulmonary aspiration in pediatric anesthetic practice is rare and a low-risk event. © 2014 John Wiley & Sons Ltd.

  7. Contact-free ultrasonic testing: applications to metrology and NDT

    International Nuclear Information System (INIS)

    Le Brun, A.

    1988-01-01

    In some cases classical ultrasonic testing is impossible because of adverse environment (high temperature, ionizing radiations, etc). Ultrasonic waves are created by laser impact and detected by electromagneto-acoustic transducers or laser interferometry. Association of ultrasonics generation by photoacoustic effect and reception by heterodyne interferometer is promising for the future [fr

  8. Ultrasonic actuation for MEMS dormancy-related stiction reduction

    Science.gov (United States)

    Kaajakari, Ville; Kan, Shyi-Herng; Lin, Li-Jen; Lal, Amit; Rodgers, M. Steven

    2000-08-01

    The use of ultrasonic pulses incident on surface micromachines has been shown to reduce dormancy-related failure. We applied ultrasonic pulses from the backside of a silicon substrate carrying SUMMiT processed surface micromachined rotors, used earlier as ultrasonic motors. The amplitude of the pulses was less than what is required to actuate the rotor (sub-threshold actuation). By controlling the ultrasonic pulse exposure time it was found that pulsed samples had smaller actuation voltages as compared to non-pulsed samples after twelve-hour dormancy. This result indicates that the micromachine stiction to surfaces during dormant period can be effectively eliminated, resulting in long-term stability of surface micromachines in critical applications.

  9. The importance of the first ultrasonic exam of newborn hips.

    Science.gov (United States)

    Grubor, Predrag; Asotic, Mithat; Biscevic, Mirza; Grubor, Milan

    2012-01-01

    Developmental hip disorder (DHD) is a disorder in development of the acetabulum which remains abrupt (dysplasia) and probably consequential cranialisation of the femur head (luxation). The aim of this paper is to establish the total number of DHD and its subtypes at the first clinical and ultrasound exam of newborns in a retrospective-prospective study made in the period from 1st Jan 2006 through to 31 Dec 2010 at the Clinic for orthopaedics and traumatology in Banja Luka. In total 6132 patients were examined and 99 cases diagnosed with DHD (dysplasia and luxation). Ultrasonic exam was done by means of electronic probe of 5-12 MHz according to standard method after Graph. Girls were significantly more present (96%). Positive family anamnesis on DHD was present with 7.8% examinee, mainly with primiparas, and/ or with 77.8% children with DHD. Dominant intrauterine risk factors for DHD were: mal position of foetus in uterus (78.6%), oligoamnion (17.9%), malformation of the spinal column of the pregnant woman (3.6%), whereas with 38.4% of children with a certain form of DHD the following were found: breech presentation, caesarean section or twin pregnancy. The clinical exam indicated DHD with 8.87% examinee, out of which hip looseness was found with 5% examinees. Ultrasonic finding was positive with 99 examinee, that is with 1.61% of them (deficient and badly formed acetabulum, sleeked protrusion; 8 luxations and 91 dysplasia). Prophylactic measures were requested by 58.6% children (abductive bending and exercises), whereas 41.4 % needed non-intervention therapeutic measures (traction, Pavlik's straps, Graph's knickers, plastering), after which there were no children needing surgical correction of DHD. These data indicate that clinical exam is unreliable for DHD diagnostics, and that Ultrasonic diagnostics and treatment of DHD should start as early as possible applying atraumatic helping devices and procedures in the period when all structures are elastic, flexible and

  10. NEET In-Pile Ultrasonic Sensor Enablement-Final Report

    Energy Technology Data Exchange (ETDEWEB)

    J. Daw; J. Rempe; J. Palmer; P. Ramuhalli; R. Montgomery; H.T. Chien; B. Tittmann; B. Reinhardt; P. Keller

    2014-09-01

    Ultrasonic technologies offer the potential to measure a range of parameters during irradiation of fuels and materials, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes under harsh irradiation test conditions. There are two primary issues that currently limit in-pile deployment of ultrasonic sensors. The first is transducer survivability. The ability of ultrasonic transducer materials to maintain their useful properties during an irradiation must be demonstrated. The second issue is signal processing. Ultrasonic testing is typically performed in a lab or field environment, where the sensor and sample are accessible. The harsh nature of in-pile testing and the variety of desired measurements demand that an enhanced signal processing capability be developed to make in-pile ultrasonic sensors viable. To address these issues, the NEET ASI program funded a three year Ultrasonic Transducer Irradiation and Signal Processing Enhancements project, which is a collaborative effort between the Idaho National Laboratory, the Pacific Northwest National Laboratory, the Argonne National Laboratory, and the Pennsylvania State University. The objective of this report is to document the objectives and accomplishments from this three year project. As summarized within this document, significant work has been accomplished during this three year project.

  11. Extrinsic Fabry-Perot ultrasonic detector

    Science.gov (United States)

    Kidwell, J. J.; Berthold, John W., III

    1996-10-01

    We characterized the performance of a commercial fiber optic extrinsic Fabry-Perot interferometer for use as an ultrasonic sensor, and compared the performance with a standard lead zirconate titanate (PZT) detector. The interferometer was unstabilized. The results showed that the fiber sensor was about 12 times less sensitive than the PZT detector. Ultrasonic frequency response near 100 kHz was demonstrated. We describe the design of the fiber sensor, the details of the tests performed, and potential applications.

  12. The correlation between the ultrasonic elastic strain ratio of thyroid cancer and the malignant biological characteristics of cancer cells in the lesions

    OpenAIRE

    Li Ma; Rong Zhou; Yun-Zhu Li

    2017-01-01

    Objective: To study the correlation between the ultrasonic elastic strain ratio of thyroid cancer and the malignant biological characteristics of cancer cells in the lesions. Methods: A total of 90 patients with thyroid cancer who accepted surgical treatment in our hospital between March 2015 and September 2016 were selected as the observation group, and 50 patients who received surgery in our hospital during the same period and were with clear pathological diagnosis of thyroid...

  13. Internal properties assessment in agar wood trees using ultrasonic velocity measurement

    International Nuclear Information System (INIS)

    Mohd Noorul Ikhsan Mohamed; Mohamad Pauzi Ismail; Mat Rasol Awang; Mohd Fajri Osman; Fakhruzi, M.; Hashim, M.M.

    2010-01-01

    This paper presents the application of ultrasonic velocity in agar wood trees (Aquilaria crassna) with the purpose of evaluating the relationship of the ultrasonic velocity to the variations of internal properties of trees. In this study, three circular cross-sectional discs from the freshly cut tree were selected as samples. First sample with a big hole (decay) in the middle, second sample with internal resinous and the last one is the sample with no defects. The through transmission ultrasonic testing method was carried out using Tico ultrasonic pulse velocity tester which is from Switzerland. Two-dimensional image of internal properties evaluation by an ultrasonic investigation was obtained using Matlab. The results showed that the ultrasonic wave cannot pass through the internal decay or resinous so that the wave went round it and thus ultrasonic wave velocity significantly decreased by increasing the hole or resinous. The difference in color of the image generated by Matlab software based on variation of ultrasonic velocity between the internal decay area and its surrounding area was obvious. Therefore, the properties of internal properties of the three could be detected by ultrasonic line imaging technique. (author)

  14. Liver CT-guided aspirative biopsies

    International Nuclear Information System (INIS)

    Santos, Gilda da Cunha; Carvalho, Leda Viegas de; Chojniak, Rubens; Morini, Sandra Regina

    1996-01-01

    Sixty-eight CT-guided aspirative biopsies of hepatic nodules were performed at A.C. Camargo Hospital, Sao Paulo, Brazil, from 1992 to 1995. The cases were distributed as follow: 44(64.7%) with a positive diagnosis for neoplastic cells, 6(8.8%) with a negative diagnosis, and 14 (20.5%) with insufficient material. Of the positive cases (primary neoplasias and metastases), the cytological diagnosis was achieved in 39 cases. There were 36 cases of carcinoma (7 hepato carcinomas, 18 adenocarcinomas, 1 small cell carcinoma and 10 cases of unspecified differentiation), 2 cases of melanoma and 1 case of melanoma and 1 case of sarcoma. The correlation with histopathological exams showed no false positive cases and concordance between cytological and histopathological diagnosis. The results demonstrate that CT-guided aspirative biopsy of hepatic nodules permits a rapid diagnosis of neoplastic lesions, especially for the evaluation of metastases. (author)

  15. Squalene aspiration pneumonia : thin-section CT and histopathologic findings

    International Nuclear Information System (INIS)

    Lee, Jin Seong; Gong, Gyung Yub; Lim, Tae Hwan

    1998-01-01

    The purpose of this study was to describe the thin-section computed tomography (CT) findings and histopathologic findings of squalene aspiration pneumonia. Thin-section CT scans were obtained from nine patients with proven exogenous lipoid pneumonia resulting from aspiration of squalene (derived from shark liver oil). The condition was diagnosed by biopsy (n=3), bronchoalveolar lavage(n=4), or sputum cytology and clinical history (n=2) of squalene use was confirmed in all patients. Specimens of transbronchial lung biopsy were also reviewed and compared with thin-section CT findings. On the basis of these results, we concluded that squalene aspiration pneumonia can be reliably diagnosed by thin-section CT findings particularly when the appropriate history is known. (author). 19 refs., 3 figs

  16. Intralesional saline injection for effective ultrasound-guided aspiration of benign viscous cystic thyroid nodules

    International Nuclear Information System (INIS)

    Ko, Eun Sook; Shin, Jung Hee; Sung, Jin Yong

    2014-01-01

    We aimed to evaluate the efficacy and safety of vigorous saline injection for viscous cystic thyroid nodules. Eighteen patients who underwent ultrasound-guided aspiration for viscous cystic thyroid nodules using a saline injection were included in our study. After failing to aspirate the cyst by the usual method, we vigorously injected saline into the cyst in multiple directions to break up and liquefy the viscous cystic contents to enable aspiration. The initial and the residual volume of the nodule were calculated, and the volume reduction rate and the time taken to perform the aspiration were recorded. The mean volume of the cystic nodules before aspiration was 11.0 mL (range, 1.2 to 26.0 mL), while the postaspiration volume was 4.2 mL (range, 0.2 to 14.5 mL). The mean aspirated volume was 63.7% of the initial volume. The mean procedure time was 12.4 minutes (range, 5 to 26 minutes). There were no significant complications related to the procedure. A vigorous saline injection followed by aspiration can be a useful method to aspirate viscous cystic thyroid nodules as a prestep for further intervention or simple management.

  17. Study of Educational Aspirations of Preparatory School Students in Yemen.

    Science.gov (United States)

    Edington, Everett D.

    To identify causes for low enrollment in secondary agricultural schools in Yemen, the United States Agency for International Development and the Yemen Ministry of Education surveyed 990 preparatory (junior high) students, examining their educational aspirations, differences between rural and urban youth, major influences on student aspirations,…

  18. Characterization of nuclear graphite elastic properties using laser ultrasonic methods

    Science.gov (United States)

    Zeng, Fan W.; Han, Karen; Olasov, Lauren R.; Gallego, Nidia C.; Contescu, Cristian I.; Spicer, James B.

    2015-05-01

    Laser ultrasonic methods have been used to characterize the elastic behaviors of commercially-available and legacy nuclear graphites. Since ultrasonic techniques are sensitive to various aspects of graphite microstructure including preferred grain orientation, microcrack orientation and porosity, laser ultrasonics is a candidate technique for monitoring graphite degradation and structural integrity in environments expected in high-temperature, gas-cooled nuclear reactors. Aspects of materials texture can be assessed by studying ultrasonic wavespeeds as a function of propagation direction and polarization. Shear wave birefringence measurements, in particular, can be used to evaluate elastic anisotropy. In this work, laser ultrasonic measurements of graphite moduli have been made to provide insight into the relationship between the microstructures and the macroscopic stiffnesses of these materials. In particular, laser ultrasonic measurements have been made using laser line sources to produce shear waves with specific polarizations. By varying the line orientation relative to the sample, shear wave birefringence measurements have been recorded. Results from shear wave birefringence measurements show that an isostatically molded graphite, such as PCIB, behaves isotropically, while an extruded graphite, such as H-451, displays significant ultrasonic texture. Graphites have complicated microstructures that depend on the manufacturing processes used, and ultrasonic texture in these materials could originate from grain orientation and preferred microcrack alignment. Effects on material isotropy due to service related microstructural changes are possible and the ultimate aim of this work is to determine the degree to which these changes can be assessed nondestructively using laser ultrasonics measurements.

  19. Pre-aspiration in Welsh English: a case study of Aberystwyth

    DEFF Research Database (Denmark)

    Hejná, Michaela

    -aspiration would be manifested as a h sound inserted in the following words as indicated: paht, peht, piht, poht, puht, mahp, mahtt, mahck, ohff, mohth, mahss, mahsh. Because the sound is understudied in English, the work focuses on what other sounds condition the presence of the phenomenon and its duration......Lay abstract This thesis examines pre-aspiration in English spoken in Aberystwyth, mid Wales. Pre-aspiration is a sound very similar to h (as in honey), and it can be found mainly in the sequences of vowels (a, e, i, o, u, etc.) and certain consonants (p, t, k, f, th, s, sh). In English, pre......, if it is sensitive to social factors such as age or gender as well, and it suggests some implications for sound changes including pre-aspiration. Chapter 1 summarises the questions addressed in this thesis and outlines where this work is positioned with respect to our current knowledge of the phenomenon...

  20. Analysis of Ultrasonic Transmitted Signal for Apple using Wavelet Transform

    International Nuclear Information System (INIS)

    Kim, Ki Bok; Lee, Sang Dae; Choi, Man Yong; Kim, Man Soo

    2005-01-01

    This study was conducted to analyze the ultrasonic transmitted signal for apple using wavelet transform. Fruit consists of nonlinear visco-elastic properties such as flesh, an ovary and rind and lienee most ultrasonic wave is attenuated and its frequency is shifted during passing the fruit. Thus it is not easy to evaluate the internal quality of the fruit using typical ultrasonic parameters such as wave velocity, attenuation, and frequency spectrum. The discrete wavelet transform was applied to the ultrasonic transmitted signal for apple. The magnitude of the first peak frequency of the wavelet basis from the ultrasonic transmitted signal showed a close correlation to the storage time of apple

  1. Ultrasonic filtration of industrial chemical solutions

    Science.gov (United States)

    Cosma, T.

    1974-01-01

    The practical results obtained as a result of filtering industrial chemical solutions under continuous flow conditions with the aid of an ultrasonic filter are presented. The main part of the assembly consists of an ultrasonic generator with an output power of about 400 W and the filtration assembly, in which there is a magnetostrictive amplifier constructed for 20.5 kHz. In addition to ensuring a continuous flow of filtered solution, ultrasonic filters can be replaced or cleaned at intervals of time that are 8-10 times greater than in the case of mechanical filters. They yield considerably better results as far as the size of the filtered particles is concerned. The parameters on which filtration quality depends are also presented.

  2. Air Bag Momentum Force Including Aspiration

    Directory of Open Access Journals (Sweden)

    Guy Nusholtz

    1995-01-01

    Full Text Available A gas-jet momentum force drives the air bag into position during a crash. The magnitude of this force can change as a result of aspiration. To determine the potential magnitude of the effect on the momentum force and mass flow rate in an aspirated system, a series of experiments and simulations of those experiments was conducted. The simulation consists of a two-dimensional unsteady isentropic CFD model with special “infinite boundaries”. One of the difficulties in simulating the gas-jet behavior is determining the mass flow rate. To improve the reliability of the mass flow rate input to the simulation, a sampling procedure involving multiple tests was used, and an average of the tests was adopted.

  3. The mean green popsicle: using cryotherapy to remove aspirated foreign bodies.

    Science.gov (United States)

    Seaman, Joseph C; Knepler, James L; Bauer, Karen; Rashkin, Mitchell

    2010-10-01

    Foreign body (FB) aspiration can be a life-threatening event. Although more common in children, FB aspiration can occur at any age. Symptoms related to FB aspiration range from coughing and shortness of breath to asphyxiation. Chest imaging can be nonspecific and infrequently identifies an FB. Herein, we describe a case of a 54-year-old male patient who aspirated an FB and experienced respiratory arrest. He failed to improve with conservative measures and required emergent bronchoscopy. He was found to have an FB in his proximal left mainstem bronchus that could not be removed using standard bronchoscopy and he was referred to our center for definitive care. We used a cryotherapy probe to remove the FB. We propose that cryotherapy is a useful tool to remove FBs that are soft and amenable to freezing.

  4. Ultrasonic imaging in LMFBRs using digital techniques

    International Nuclear Information System (INIS)

    Fothergill, J.R.; McKnight, J.A.; Barrett, L.M.

    Ultrasonic technology for providing images of components immersed in the opaque sodium of LMFBRs is being developed at RNL. For many years the application has been restricted by the unavailability of convenient ultrasonic sources and receivers capable of withstanding the reactor environment. Until recently, for example, important ultrasonic instrument design, such as for future sweep arms, had to be based on waveguided ultrasonics. RNL have developed an economic immersible transducer that can be deployed during reactor shut-down, when many demands for ultrasonic imaging are made. The transducer design is not suited at present to the sophisticated techniques of phased arrays; consequently image formation must depend on the physical scanning of a target using one or more transducers in pulse-echo mode. The difficulties of access into a fast reactor impose further restrictions. Some applications may involve easy scanning sequences, thus the sweep arm requires only a rotation to provide a map of the reactor core area. For a more detailed examination of the same area, however, special engineering solutions are needed to provide a more satisfactory scanning sequence. A compromise solution involving the rotating shield movement is being used for a PFR experiment to examine a limited area of the core. (author)

  5. Hardware Developments of an Ultrasonic Tomography Measurement System

    Directory of Open Access Journals (Sweden)

    Hudabiyah ARSHAD AMARI

    2010-01-01

    Full Text Available This research provides new technique in ultrasonic tomography by using ultrasonic transceivers instead of using separate transmitter-receiver pair. The numbers of sensors or transducers used to acquire data plays an important role to generate high resolution tomography images. The configuration of these sensors is a crucial factor in the efficiency of data acquisition. Instead of using common separated transmitter – receiver, an alternative approach has been taken to use dual functionality ultrasonic transceiver. A prototype design of sensor’s jig that will hold 16 transceivers of 14.1mm has been design. Transmission-mode approach with fan beam technique has been used for sensing the flow of gas, liquid and solid. This paper also explains the circuitry designs for the Ultrasonic Tomography System.

  6. Ultrasonic system for NDE of fruits and vegetables

    International Nuclear Information System (INIS)

    Jhang, Kyung Young; Jung, Gyoo Hong; Kim, Man Soo

    1999-01-01

    The nondestructive internal quality evaluation of agricultural products has been strongly required from the needs for individual inspection. In recent, ultrasonic wave has been considered as a solution for this problem. This study is to construct the ultrasonic inspection system for fruits and vegetables on the basis of pre-knowledge that general frequency band(higher than 100 kHz) ultrasonic waves do not transmitted well due to severe attenuation. Our system includes ultrasonic pulser and receiver, transducers(50 kHz), acoustic hem, pneumatic controller and signal processing units (PC). In order to confirm the performance, several samples (apple, pear, persimmon, kiwi fruit, potato and radish) were tested, and the results showed sufficient possibility to apply to NDE of fruits and vegetables.

  7. Bio rapid prototyping by extruding/aspirating/refilling thermoreversible hydrogel

    International Nuclear Information System (INIS)

    Iwami, K; Noda, T; Ishida, K; Umeda, N; Morishima, K; Nakamura, M

    2010-01-01

    This paper reports a method for rapid prototyping of cell tissues, which is based on a system that extrudes, aspirates and refills a mixture of cells and thermoreversible hydrogel as a scaffold. In the extruding mode, a cell-mixed scaffold solution in the sol state is extruded from a cooled micronozzle into a temperature-controlled substrate, which keeps the scaffold in the gel state. In the aspiration mode, the opposite process is performed by Bernoulli suction. In the refilling mode, the solution is extruded into a groove created in the aspiration mode. The minimum width of extruded hydrogel pattern is 114 ± 15 μm by employing a nozzle of diameter 100 μm, and that of aspirated groove was 355 ± 10 μm using a 500 μm-diameter nozzle. Gum arabic is mixed with the scaffold solution to avoid peeling-off of the gel pattern from the substrate. Patterning of Sf-9 cell tissue is demonstrated, and the stability of the patterned cell is investigated. This system offers a procedure for rapid prototyping and local modification of cell scaffolds for tissue engineering.

  8. On line ultrasonic integrated backscatter

    International Nuclear Information System (INIS)

    Landini, L.; Picano, E.; Mazzarisi, A.; Santarelli, F.; Benassi, A.; De Pieri, G.

    1988-01-01

    A new equipment for on-line evaluation of index based on two-dimensional integrated backscatter from ultrasonic images is described. The new equipment is fully integrated into a B-mode ultrasonic apparatus which provides a simultaneous display of conventional information together with parameters of tissue characterization. The system has been tested with a backscattering model of microbubbles in polysaccharide solution, characterized by a physiological exponential time decay. An exponential fitting to the experimental data was performed which yielded r=0.95

  9. Ultrasonic-assisted manufacturing processes: Variational model and numerical simulations

    KAUST Repository

    Siddiq, Amir

    2012-04-01

    We present a computational study of ultrasonic assisted manufacturing processes including sheet metal forming, upsetting, and wire drawing. A fully variational porous plasticity model is modified to include ultrasonic softening effects and then utilized to account for instantaneous softening when ultrasonic energy is applied during deformation. Material model parameters are identified via inverse modeling, i.e. by using experimental data. The versatility and predictive ability of the model are demonstrated and the effect of ultrasonic intensity on the manufacturing process at hand is investigated and compared qualitatively with experimental results reported in the literature. © 2011 Elsevier B.V. All rights reserved.

  10. Megakaryocytic alterations in thrombocytopenia: A bone marrow aspiration study

    Directory of Open Access Journals (Sweden)

    Muhury Manas

    2009-10-01

    Full Text Available Context: Dysplastic changes are well documented in myelodysplastic syndromes (MDS. However, they are also observed in non-MDS hematological conditions. Aims: To evaluate the megakaryocytic alterations in the bone marrow aspirations in cases of non-MDS related thrombocytopenia. Setting and Design: A prospective study of 144 bone marrow aspirates was conducted in the department of pathology, Kasturba Medical College, Mangalore. The aspirates were studied to assess the number and morphology of the megakaryocytes in non-MDS related thrombocytopenia and evaluate their significance when compared to changes in MDS. Materials and Methods: The bone marrow aspiration smears were stained with Leishman stain and examined under light microscope. Statistical Analysis Used: Fisher′s exact test. A P value less than 0.05 was considered significant. Sensitivity and specificity was calculated for those features which were significant in the relevant hematological disorders. Results: The sensitivity of immature megakaryocytes, dysplastic forms and micromegakaryocytes in cases of immune thrombocytopenic purpura was 100%, 89% and 42% respectively. The specificity of emperipolesis was 74%. In cases of infection-associated thrombocytopenia, immature megakaryocytes had a sensitivity of 100% and cytoplasmic vacuolization were 86% specific. The sensitivity of the dysplastic forms in megaloblastic anemia was 75%. However, no platelet budding was observed. The presence of micromegakaryocyte had a specificity of 83% in MDS, and was statistically significant when compared to cases of non-MDS conditions (P< 0.05. Conclusions: Careful understanding of the morphological changes of megakaryocytes in bone marrow aspirates can improve the diagnostic accuracy for a wide range of hematological disorders thereby enabling proper therapeutic interventions.

  11. Computer-aided ultrasonic inspection of steam turbine rotors

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, K H; Weber, M; Weiss, M [GEC ALSTHOM Energie GmbH, Nuremberg (Germany)

    1999-12-31

    As the output and economic value of power plants increase, the detection and sizing of the type of flaws liable to occur in the rotors of turbines using ultrasonic methods assumes increasing importance. An ultrasonic inspection carried out at considerable expense is expected to bring to light all safety-relevant flaws and to enable their size to be determined so as to permit a fracture-mechanics analysis to assess the reliability of the rotor under all possible stresses arising in operation with a high degree of accuracy. The advanced computer-aided ultrasonic inspection of steam turbine rotors have improved reliability, accuracy and reproducibility of ultrasonic inspection. Further, there has been an improvement in the resolution of resolvable group indications by applying reconstruction and imagine methods. In general, it is also true for the advanced computer-aided ultrasonic inspection methods that, in the case of flaw-affected forgings, automated data acquisition provides a substantial rationalization and a significant documentation of the results for the fracture mechanics assessment compared to manual inspection. (orig.) 8 refs.

  12. Computer-aided ultrasonic inspection of steam turbine rotors

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, K.H.; Weber, M.; Weiss, M. [GEC ALSTHOM Energie GmbH, Nuremberg (Germany)

    1998-12-31

    As the output and economic value of power plants increase, the detection and sizing of the type of flaws liable to occur in the rotors of turbines using ultrasonic methods assumes increasing importance. An ultrasonic inspection carried out at considerable expense is expected to bring to light all safety-relevant flaws and to enable their size to be determined so as to permit a fracture-mechanics analysis to assess the reliability of the rotor under all possible stresses arising in operation with a high degree of accuracy. The advanced computer-aided ultrasonic inspection of steam turbine rotors have improved reliability, accuracy and reproducibility of ultrasonic inspection. Further, there has been an improvement in the resolution of resolvable group indications by applying reconstruction and imagine methods. In general, it is also true for the advanced computer-aided ultrasonic inspection methods that, in the case of flaw-affected forgings, automated data acquisition provides a substantial rationalization and a significant documentation of the results for the fracture mechanics assessment compared to manual inspection. (orig.) 8 refs.

  13. The outcome of laparoscopic cholecystectomy by ultrasonic dissection.

    LENUS (Irish Health Repository)

    Sasi, Walid

    2010-04-01

    Electrocautery remains the main energy form used for dissection in laparoscopic cholecystectomy. However, due to its many risks the search continues for safer and more efficient forms of energy. This chapter assesses the outcomes of dissection using ultrasonic energy as compared to monopolar electrocautery during laparoscopic cholecystectomy. Studies included are trials of prospectively randomized adult patients with symptomatic gallstone disease subject either ultrasonic or monopolar electrocautery dissection during laparoscopic cholecystectomy. Seven trials were included in this review, with a total patient number of 695 randomized to two dissection methods: 340 in the electrocautery group and 355 in the ultrasonic group. Ultrasonic dissection is shown to be superior to monopolar electrocautery in laparoscopic cholecystectomy. Disadvantages include a difficult maneuvering technique and overall cost. Appropriate training programs may be implemented to overcome the first disadvantage, and it might be argued that given the combined cost of factors associated with standard clip and cautery technique, cost issues may be outweighed by the benefits of ultrasonic dissection. However, this necessitates further cost-benefit analysis.

  14. The Effect of Maternal Employment on Schoolchildren's Educational Aspirations in Korea.

    Science.gov (United States)

    Ju, Dong-Beom; Chung, Il-Hwan

    2000-01-01

    Examined the relationships between maternal employment and schoolchildren's educational aspirations in Korea. Found that children whose mothers were working full-time had lower educational aspirations, although maternal involvement and parents' educational expectations mitigated these effects. (JPB)

  15. Ultrasonic extraction of flavonoids and phenolics from loquat ...

    African Journals Online (AJOL)

    Administrator

    2011-06-08

    Jun 8, 2011 ... ultrasonic pharmaceutical managing machine (Sinobest electronic. Co. Ltd., Jining, Shangdong ... During the ultrasonic treatment, the temperature ..... essential oil extraction by a hydrodistillation process using a 2(4) complete ...

  16. Nondestructive control of materials by ultrasonic tests

    International Nuclear Information System (INIS)

    Mercier, Noelle.

    1974-01-01

    A bibliographic study of nondestructive control methods of solids by ultrasonic tests, and of the ultrasonic emission of a transducer of finite dimension, is first presented. The principle of two of these methods is verified experimentally; they should permit the measurement of various physical parameters of solids, and the detection of local inhomogeneities. The first method calls upon the analysis of the ultrasonic signal (amplitude and phase), after it has crossed a constant thickness of a metallic specimen. This analysis reveals variations of attenuation and of ultrasonic propagation velocity within the specimen. A good spatial resolution is obtained by using 1mm-diameter probes. The second method leads, thanks to a test rig equipped with broad frequency band electrostatic transducers, to the knowledge of the attenuation law of the specimens as a function of frequency (present range: 5 to 15MHz); from this a classification of these specimens as regards their granulometry is deduced [fr

  17. Advanced ultrasonic technology for natural gas measurement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-11-15

    In recent years, due to rising environmental and safety concerns, increasing commodity prices, and operational inefficiencies, a paradigm shift has been taking place with respect to gas measurement. The price of natural gas depends on the location, time of the year, and type of consumer. There is wide uncertainty associated with an orifice meter. This paper presents the use of advanced ultrasonic technology for the measurement of natural gas. For many years, multi-path ultrasonic meters with intelligent sensor technology have been used for gas measurement. This paper gives the various applications of ultrasonic technology along with their advantages and a draws a comparison with orifice meters. From the study it can be concluded that extensive advances in the use of ultrasonic technology for gas measurement have widened the areas of application and that varying frequencies combined with sealed transducer designs make it possible to measure atmospheric and sour gas in custody transfer process control and flaring accurately.

  18. Frequency and amplitude dependences of molding accuracy in ultrasonic nanoimprint technology

    International Nuclear Information System (INIS)

    Mekaru, Harutaka; Takahashi, Masaharu

    2009-01-01

    We use neither a heater nor ultraviolet lights, and are researching and developing an ultrasonic nanoimprint as a new nano-patterning technology. In our ultrasonic nanoimprint technology, ultrasonic vibration is not used as a heat generator instead of the heater. A mold is connected with an ultrasonic generator, and mold patterns are pushed down and pulled up at a high speed into a thermoplastic. Frictional heat is generated by ultrasonic vibration between mold patterns and thermoplastic patterns formed by an initial contact force. However, because frictional heat occurs locally, the whole mold is not heated. Therefore, a molding material can be comprehensively processed at room temperature. A magnetostriction actuator was built into our ultrasonic nanoimprint system as an ultrasonic generator, and the frequency and amplitude can be changed between dc–10 kHz and 0–4 µm, respectively. First, the ultrasonic nanoimprint was experimented by using this system on polyethylene terephthalate (PET, T g = 69 °C), whose the glass transition temperature (T g ) is comparatively low in engineering plastics, and it was ascertained that the most suitable elastic material for this technique was an ethyl urethane rubber. In addition, we used a changeable frequency of the magnetostriction actuator, and nano-patterns in an electroformed-Ni mold were transferred to a 0.5 mm thick sheet of PET, polymethylmethacrylate (PMMA) and polycarbonate (PC), which are typical engineering plastics, under variable molding conditions. The frequency and amplitude dependence of ultrasonic vibration to the molding accuracy were investigated by measuring depth and width of imprinted patterns. As a result, regardless of the molding material, the imprinted depth was changed drastically when the frequency exceeded 5 kHz. On the other hand, when the amplitude of ultrasonic vibration grew, the imprinted depth gradually deepened. Influence of the frequency and amplitude of ultrasonic vibration was not

  19. Adaptive aspirations and performance heterogeneity : Attention allocation among multiple reference points

    NARCIS (Netherlands)

    Blettner, D.P.; He, Z.; Hu, S.; Bettis, R.

    Organizations learn and adapt their aspiration levels based on reference points (prior aspiration, prior performance, and prior performance of reference groups). The relative attention that organizations allocate to these reference points impacts organizational search and strategic decisions.

  20. Surgical versus non-surgical management for pleural empyema.

    Science.gov (United States)

    Redden, Mark D; Chin, Tze Yang; van Driel, Mieke L

    2017-03-17

    Empyema refers to pus in the pleural space, commonly due to adjacent pneumonia, chest wall injury, or a complication of thoracic surgery. A range of therapeutic options are available for its management, ranging from percutaneous aspiration and intercostal drainage to video-assisted thoracoscopic surgery (VATS) or thoracotomy drainage. Intrapleural fibrinolytics may also be administered following intercostal drain insertion to facilitate pleural drainage. There is currently a lack of consensus regarding optimal treatment. To assess the effectiveness and safety of surgical versus non-surgical treatments for complicated parapneumonic effusion or pleural empyema. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (2016, Issue 9), MEDLINE (Ebscohost) (1946 to July week 3 2013, July 2015 to October 2016) and MEDLINE (Ovid) (1 May 2013 to July week 1 2015), Embase (2010 to October 2016), CINAHL (1981 to October 2016) and LILACS (1982 to October 2016) on 20 October 2016. We searched ClinicalTrials.gov and WHO International Clinical Trials Registry Platform for ongoing studies (December 2016). Randomised controlled trials that compared a surgical with a non-surgical method of management for all age groups with pleural empyema. Two review authors independently assessed trials for inclusion and risk of bias, extracted data, and checked the data for accuracy. We contacted trial authors for additional information. We assessed the quality of the evidence using the GRADE approach. We included eight randomised controlled trials with a total of 391 participants. Six trials focused on children and two on adults. Trials compared tube thoracostomy drainage (non-surgical), with or without intrapleural fibrinolytics, to either VATS or thoracotomy (surgical) for the management of pleural empyema. Assessment of risk of bias for the included studies was generally unclear for selection and blinding but low for attrition and reporting bias. Data analyses compared

  1. The digital ultrasonic test unit for automatic equipment

    International Nuclear Information System (INIS)

    Hiraoka, T.; Matsuyama, H.

    1976-01-01

    The operations and features of the ultrasonic test unit used and the digital data processing techniques employed are described. This unit is used for a few hundred multi-channel automatic ultrasonic test equipment

  2. Aspiration of barium contrast medium in an elderly man with disordered swallowing

    OpenAIRE

    Bağcı Ceyhan, B.; Çelikel, T.; Koç, M.; Ahıskalı, R.; Biren, T.; Ataizi Çelikel, Ç.

    1995-01-01

    The aspiration of contrast medium during the investigation of gastrointestinal diseases is a well recognized hazard, particularly in patients with swallowing disorders. A case is reported in which accidental aspiration of contrast barium occurred owing to disordered swallowing in an elderly man. The infiltration on chest x-ray persisted 2 years after barium contrast aspiration. Inflammatory reaction and retractile, granular material observed in lung biopsy specimens suggested barium-induced p...

  3. Design of ultrasonic probe and evaluation of ultrasonic waves on E.coli in Sour Cherry Juice

    Directory of Open Access Journals (Sweden)

    B Hosseinzadeh Samani

    2015-09-01

    Full Text Available Introduction: The common method used for juice pasteurization is the thermal method since thermal methods contribute highly to inactivating microbes. However, applying high temperatures would lead to inefficient effects on nutrition and food value. Such effects may include vitamin loss, nutritional flavor loss, non-enzyme browning, and protein reshaping (Kuldiloke, 2002. In order to decrease the adverse effects of the thermal pasteurization method, other methods capable of inactivation of microorganisms can be applied. In doing so, non-thermal methods including pasteurization using high hydrostatic pressure processing (HPP, electrical fields, and ultrasound waves are of interest (Chen and Tseng, 1996. The reason for diminishing microbial count in the presence of ultrasonic waves could be due to the burst of very tiny bubbles developed by ultrasounds which expand quickly and burst in a short time. Due to this burst, special temperature and pressure conditions are developed which could initiate or intensify several physical and/or chemical reactions. The aim of this study is to evaluate the non-thermal ultrasonic method and its effective factors on the E.coli bacteria of sour cherry. Materials and methods: In order to supply uniform ultrasonic waves, a 1000 W electric generator (Model MPI, Switzerland working at 20±1 kHz frequency was used. The aim of this study is to evaluate the non-thermal ultrasonic method and its effective factors on the E.coli bacteria of sour cherry. For this purpose, a certain amount of sour cherry fruit was purchased from local markets. First, the fruits were washed, cleaned and cored. The prepared fruits were then dewatered using an electric juicer. In order to separate pulp suspensions and tissue components, the extracted juice was poured into a centrifuge with the speed of 6000 rpm for 20 min. For complete separation of the remaining suspended particles, the transparent portion of the extract was passed through a

  4. Miniaturized and general purpose fiber optic ultrasonic sources

    International Nuclear Information System (INIS)

    Biagi, E.; Fontani, S.; Masotti, L.; Pieraccini, M.

    1997-01-01

    Innovative photoacoustic sources for ultrasonic NDE, smart structure, and clinical diagnosis are proposed. The working principle is based on thermal conversion of laser pulses into a metallic film evaporated directly onto the tip of a fiber optic. Unique features of the proposed transducers are very high miniaturization and potential easy embedding in smart structure. Additional advantages, high bedding in smart structure. Additional advantages, high ultrasonic frequency, large and flat bandwidth. All these characteristics make the proposed device an ideal ultrasonic source

  5. Aspiration-based coevolution of link weight promotes cooperation in the spatial prisoner's dilemma game

    Science.gov (United States)

    Shen, Chen; Chu, Chen; Shi, Lei; Perc, Matjaž; Wang, Zhen

    2018-05-01

    In this article, we propose an aspiration-based coevolution of link weight, and explore how this set-up affects the evolution of cooperation in the spatial prisoner's dilemma game. In particular, an individual will increase the weight of its link to its neighbours only if the payoff received via this interaction exceeds a pre-defined aspiration. Conversely, if the received payoff is below this aspiration, the link weight with the corresponding neighbour will decrease. Our results show that an appropriate aspiration level leads to a high-cooperation plateau, whereas too high or too low aspiration will impede the evolution of cooperation. We explain these findings with a comprehensive analysis of transition points and with a systematic analysis of typical configuration patterns. The presented results provide further theoretical insights with regards to the impact of different aspiration levels on cooperation in human societies.

  6. Complex radiological diagnosis and choice of a method of surgical treatment of the lung and the liver hydatidosis

    International Nuclear Information System (INIS)

    Ikramov, A.I.

    2003-01-01

    In dissertation work there were analyzed results of diagnosis and surgical treatment 1.741 patients with lung and liver hydatidosis. The investigations were executed with application of a complex of radiologic methods such X-ray, sonography, CT and MRI tomography. Were analyzed separate and cumulative information of the listed methods on the basis of their sensitivity, specificity and general accuracy. The questions of classification of complicated forms of the lung hydatidosis and criteria to differential diagnosis of spherical lung formations and liver focal formations are discussed. The technique of transthoracic sonography for revealing and differential diagnostics subpleural localization of the hydatidosis and congestions of a liquid in pleural cavity is developed. The indications and contraindications to use transcutaneus fine needle biopsy for diagnostics of the hydatidosis are determined. On the basis of results of complex X-ray diagnostics the original algorithms of a sequence of performance various methods of visualization are developed. The indications to performance pancreatocholangiography are proved at suspicion on ruptured hydatid cysts into biliar tract with mechanical jaundice. The analysis of results of traditional surgical treatment of the hydatidosis, and low invasive transcutaneus procedures, endovisual surgical operations and chemotherapy is carried out. The indications to performance of the listed methods are developed depending on the form and stage of disease, localization of cysts. Were analyzed results of transcutaneus aspiration and drainage of residual cavities after hydatidectomy. The comparative estimation to traditional surgical methods, CT- and US-guided transcutaneus aspirations, drainage is given. Are determined a role and place of complex radiological diagnosis with use sonography, X-ray and CT in early and late postoperative complications after hydatidectomy from the lung and liver (pleural effusion, subdiaphragmal abscess and

  7. Utility of CT-guided abdominal aspiration procedures

    International Nuclear Information System (INIS)

    Sundaram, M.; Wolverson, M.K.; Heiberg, E.; Pilla, T.; Vas, W.G.; Shields, J.B.

    1982-01-01

    Over 200 consecutive diagnostic needle aspiration procedures of the abdomen were performed under computed tomographic (CT) guidance. Biopsies were done of the liver in 88 patients, the pancreas in 28, the kidney in 20, and the retroperitoneum in 32; 30 underwent an aspiration procedure for characterization of an intraabdominal fluid collection. Accuracy of diagnosis was very high for hepatic (99%) and renal (100%) biopsies and in characterization of fluid collections (100%). Accuracy for retroperitoneal biopsy was 87.5% and for pancreatic biopsy 82%. Overall accuracy for all sites was 95%. There were one false-negative diagnosis for the liver and five false-negative diagnoses for the pancreas. Insufficient material was obtained for diagnosis in four instances of retroperitoneal biopsy. There were no false positives. The technique is facilitated by rapid CT scan time, large aperture gantry, and rapid CT image reconstruction. Twenty gauge needles were used more frequently than 22 gauge needles because of their greater rigidity and ease of control. CT-guided diagnostic aspiration procedures are particularly useful for diagnosis of small, deep-seated lesions and in evaluation of lesions found in severely ill patients. An experienced cytologist is essential to the success of the technique

  8. Considerations for ultrasonic testing application for on-orbit NDE

    Science.gov (United States)

    Koshti, Ajay M.

    2015-04-01

    The paper addresses some on-orbit nondestructive evaluation (NDE) needs of NASA for International Space Station (ISS). The presentation gives NDE requirements for inspecting suspect damage due to micro-meteoroids and orbital debris (MMOD) impact on the pressure wall of the ISS. This inspection is meant to be conducted from inside of the ISS module. The metallic wall of the module has a fixed wall thickness but also has integral orthogrid ribs for reinforcement. Typically, a single MMOD hit causes localized damage in a small area causing loss of material similar to pitting corrosion, but cracks may be present too. The impact may cause bulging of the wall. Results of the ultrasonic and eddy current demonstration scans on test samples are provided. The ultrasonic technique uses shear wave scans to interrogate the localized damage area from the surrounding undamaged area. The scanning protocol results in multiple scans, each with multiple "vee" paths. A superimposition and mosaic of the three-dimensional ultrasonic data from individual scans is desired to create C-scan images of the damage. This is a new data reduction process which is not currently implemented in state-of-art ultrasonic instruments. Results of ultrasonic scans on the simulated MMOD damage test plates are provided. The individual C-scans are superimposed manually creating mosaic of the inspection. The resulting image is compared with visibly detected damage boundaries, X-ray images, and localized ultrasonic and eddy current scans for locating crack tips to assess effectiveness of the ultrasonic scanning. The paper also discusses developments needed in improving ergonomics of the ultrasonic testing for on-orbit applications.

  9. Process Stability of Ultrasonic-Wave-Assisted Gas Metal Arc Welding

    Science.gov (United States)

    Fan, Chenglei; Xie, Weifeng; Yang, Chunli; Lin, Sanbao; Fan, Yangyang

    2017-10-01

    As a newly developed arc welding method, ultrasonic-wave-assisted arc welding successfully introduced power ultrasound into the arc and weld pool, during which the ultrasonic acts on the top of the arc in the coaxial alignment direction. The advanced process for molten metals can be realized by using an additional ultrasonic field. Compared with the conventional gas metal arc welding (GMAW), the welding arc is compressed, the droplet size is decreased, and the droplet transfer frequency is increased significantly in ultrasonic-wave-assisted GMAW (U-GMAW). However, the stability of the metal transfer has deep influence on the welding quality equally, and the ultrasonic wave effect on the stability of the metal transfer is a phenomenon that is not completely understood. In this article, the stabilities of the short-circuiting transfer process and globular transfer process are studied systematically, and the effect of ultrasonic wave on the metal transfer is analyzed further. The transfer frequency and process stability of the U-GMAW process are much higher than those of the conventional GMAW. Analytical results show that the additional ultrasonic wave is helpful for improving welding stability.

  10. Study on the development of ultrasonic gas flowmeter

    International Nuclear Information System (INIS)

    Hwang, Won Ho; Park, Sang Gug; Yang, Kyu Hong; Jhang, Kyung Young

    2001-01-01

    Ultrasonic flowmeters have more advantages than the conventional method using pressure-difference. In these reasons, many advanced nations are already selling the commercial model. In RIST, we have been developed ultrasonic gas flow meter for the localization since a project was been contracted with POSCO in 1997. This paper describes a new ultrasonic gas flowmeter. This ultrasonic gas flowmeter is developed for accurate measurement of gases in a harsh environmental conditions. It is especially suited for measuring LDG, COG, BFG gases produced in iron and steel making process. In this study, we had developed the commercial model about the first tested model and applied a completed system to the POSCO gas line. Its performance has already well been proven by extensive field tests for several months in POSCO, iron and steel making company

  11. Method of noncontacting ultrasonic process monitoring

    Science.gov (United States)

    Garcia, Gabriel V.; Walter, John B.; Telschow, Kenneth L.

    1992-01-01

    A method of monitoring a material during processing comprising the steps of (a) shining a detection light on the surface of a material; (b) generating ultrasonic waves at the surface of the material to cause a change in frequency of the detection light; (c) detecting a change in the frequency of the detection light at the surface of the material; (d) detecting said ultrasonic waves at the surface point of detection of the material; (e) measuring a change in the time elapsed from generating the ultrasonic waves at the surface of the material and return to the surface point of detection of the material, to determine the transit time; and (f) comparing the transit time to predetermined values to determine properties such as, density and the elastic quality of the material.

  12. Fast synthesize ZnO quantum dots via ultrasonic method.

    Science.gov (United States)

    Yang, Weimin; Zhang, Bing; Ding, Nan; Ding, Wenhao; Wang, Lixi; Yu, Mingxun; Zhang, Qitu

    2016-05-01

    Green emission ZnO quantum dots were synthesized by an ultrasonic sol-gel method. The ZnO quantum dots were synthesized in various ultrasonic temperature and time. Photoluminescence properties of these ZnO quantum dots were measured. Time-resolved photoluminescence decay spectra were also taken to discover the change of defects amount during the reaction. Both ultrasonic temperature and time could affect the type and amount of defects in ZnO quantum dots. Total defects of ZnO quantum dots decreased with the increasing of ultrasonic temperature and time. The dangling bonds defects disappeared faster than the optical defects. Types of optical defects first changed from oxygen interstitial defects to oxygen vacancy and zinc interstitial defects. Then transformed back to oxygen interstitial defects again. The sizes of ZnO quantum dots would be controlled by both ultrasonic temperature and time as well. That is, with the increasing of ultrasonic temperature and time, the sizes of ZnO quantum dots first decreased then increased. Moreover, concentrated raw materials solution brought larger sizes and more optical defects of ZnO quantum dots. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Ultrasonic monitoring of Iberian fat crystallization during cold storage

    International Nuclear Information System (INIS)

    Corona, E; García-Pérez, J V; Santacatalina, J V; Peña, R; Benedito, J

    2012-01-01

    The aim of this work was to evaluate the use of ultrasonic measurements to characterize the crystallization process and to assess the textural changes of Iberian fat and Iberian ham during cold storage. The ultrasonic velocity was measured in two types of Iberian fats (Montanera and Cebo) during cold storage (0, 2, 5, 7 and 10 °C) and in vacuum packaged Iberian ham stored at 6°C for 120 days. The fatty acid profile, thermal behaviour and textural properties of fat were determined. The ultrasonic velocity and textural measurements showed a two step increase during cold storage, which was related with the separate crystallization of two fractions of triglycerides. It was observed that the harder the fat, the higher the ultrasonic velocity. Likewise, Cebo fat resulted harder than Montanera due to a higher content of saturated triglycerides. The ultrasonic velocity in Iberian ham showed an average increase of 55 m/s after 120 days of cold storage due to fat crystallization. Thus, non-destructive ultrasonic technique could be a reliable method to follow the crystallization of fats and to monitor the changes in the textural properties of Iberian ham during cold storage.

  14. Piezoelectric Nanotube Array for Broadband High-Frequency Ultrasonic Transducer.

    Science.gov (United States)

    Liew, Weng Heng; Yao, Kui; Chen, Shuting; Tay, Francis Eng Hock

    2018-03-01

    Piezoelectric materials are vital in determining ultrasonic transducer and imaging performance as they offer the function for conversion between mechanical and electrical energy. Ultrasonic transducers with high-frequency operation suffer from performance degradation and fabrication difficulty of the demanded piezoelectric materials. Hence, we propose 1-D polymeric piezoelectric nanostructure with controlled nanoscale features to overcome the technical limitations of high-frequency ultrasonic transducers. For the first time, we demonstrate the integration of a well-aligned piezoelectric nanotube array to produce a high-frequency ultrasonic transducer with outstanding performance. We find that nanoconfinement-induced polarization orientation and unique nanotube structure lead to significantly improved piezoelectric and ultrasonic transducing performance over the conventional piezoelectric thin film. A large bandwidth, 126% (-6 dB), is achieved at high center frequency, 108 MHz. Transmission sensitivity of nanotube array is found to be 46% higher than that of the monolithic thin film transducer attributed to the improved electromechanical coupling effectiveness and impedance match. We further demonstrate high-resolution scanning, ultrasonic imaging, and photoacoustic imaging using the obtained nanotube array transducers, which is valuable for biomedical imaging applications in the future.

  15. The sweet lung: Chewing gummi bear aspiration.

    Science.gov (United States)

    Tavladaki, Theonimfi; Fitrolaki, Michaela-Diana; Spanaki, Anna-Maria; Ilia, Staurula; Geromarkaki, Elissabet; Briassoulis, George

    2012-07-01

    Inhalation of foreign bodies, a leading cause of accidental death, is most common in preschool children. In this article we report our experience with a 5-year-old Greek girl who presented with a 24-hour history of sore throat, chest pain, and shortness of breath. Emergency bronchoscopy was performed and multiple small chewing gummi bear (HARIBO) particles impacted in the orifices of the right main bronchus and right lobar and segmentalinic bronchi were successfully removed and aspirated. Aspiration of gummi bears, which is for the first time reported, may cause a silent choking episode leading to life-threatening bronchi obstruction at multiple sites, even in children older than 4 years.

  16. [Destruction of synovial pannus of antigen-induced arthritis by ultrasonic cavitation in rabbits].

    Science.gov (United States)

    Zhang, Ling-yan; Qiu, Li; Wang, Lei; Lin, Ling; Wen, Xiao-rong

    2011-11-01

    To optimize the conditions of ultrasonic irradiation and microbubble of ultrasound cavitation on destruction of synovial pannus of antigen-induced arthritis (AIA) in rabbits. Antigen-induced arthritis was successfully induced on bilateral knee joints of 85 rabbits. Each 10 AIA rabbits were divided into two groups to compare various peak negative pressures, different ultrasonic pulse durations, various pulse repetition frequencies, different irradiance duration, different dosages of microbubble contrast agents, different ultrasonic irradiance times. With intravenous infusion of Sonovue to the rabbits, ultrasonic irradiance was performed on the right knee joint using the above condition of ultrasound cavitation. At the day 1 after ultrasonic irradiance, MRI and pathological examination were employed to evaluate the optimal conditions. The optimal parameters and conditions for ultrasonic irradiance included intermittent ultrasonic application (in 6 s intervals), 0.6 mL/kg of microbubble contrast agent, 4.6 MPa of ultrasonic peak negative pressure, 100 cycles of pulse duration, 50 Hz of pulse repetition frequency, 5 min of ultrasonic duration, 0.6 mL/kg of dosages of microbubble contrast agents and multi-sessional ultrasonic irradiance. After the ultrasonic irradiance, the thickness of right knee synovium measured by MRI was thinner than that of left knee and synovial necrosis was confirmed by the pathological finding. Under optimal ultrasonic irradiation and microbubble conditions, ultrasonic cavitation could destroy synovial pannus of AIA in rabbits.

  17. Aspiration and tetracycline sclerotherapy of primary vaginal hydrocoele of testis in adults.

    Science.gov (United States)

    Ali, Johar; Anwar, Waqas; Akbar, Mohammad; Akbar, Syed Ali; Zafar, Arshad

    2008-01-01

    Primary Vaginal Hydrocoele of Testis is a common condition which is primarily treated surgically. Many patients with Hydrocoele of testis are either not willing or are unfit for surgery. This study was done to know the safety, efficacy and out come of tetracycline induced sclerotherapy of Primary Vaginal Hydrocoele of Testis in adults. This quasi experimental study was done in Shahina Jamil Hospital, attached with Frontier Medical College and Ayub Teaching Hospital, Abbottabad from March 2006 to April, 2007. Thirty-seven patients with primary vaginal hydrocoele were included in the study. Aspiration and instillation of Tetracycline was done after spermatic cord block with 2% lignocaine. Procedure time, Peri and Post-procedure complications, number of injections for cure and patients' satisfaction with the procedure were recorded. Patients were discharged home 3 to 4 hours after the procedure and followed up after one week, one month, three months and six months. Direct admission and re-admissions were recorded. The mean age of patients was 47 years. Mean procedure time was 45 minutes. All patients were cured. Mild postoprocedure pain occurred in 12 (40%), moderate pain in 14 (46%) patients and severe pain in 4 (13.3%) patients. No patient developed haematoma or local infection. One patient (3.3%) had micturition problem. Two (6.6%) patients had minimal recurrence. One injection was sufficient for cure in all patients. 28 (93%) patients were satisfied while 2 (6.6%) patients were not satisfied with this procedure. No patient was admitted in the hospital after the procedure. Aspiration and injection of tetracycline in Primary vaginal Hydrocoele of Testis in adults is safe, effective and very economical procedure.

  18. Aspiration and tetracycline sclerotherapy of primary vaginal hydrocoele of testis in adults

    International Nuclear Information System (INIS)

    Ali, J.; Anwar, W.

    2008-01-01

    Primary Vaginal Hydrocoele of Testis is a common condition which is primarily treated surgically. Many patients with Hydrocoele of testis are either not willing or are unfit for surgery. This study was done to know the safety, efficacy and out come of tetracycline induced sclerotherapy of Primary Vaginal Hydrocoele of Testis in adults. This quasi experimental study was done in Shahina Jamil Hospital, attached with Frontier Medical College and Ayub Teaching Hospital, Abbottabad from March 2006 to April, 2007. Thirty-seven patients with primary vaginal hydrocoele were included in the study. Aspiration and instillation of Tetracycline was done after spermatic cord block with 2% lignocaine. Procedure time, Peri and Post-procedure complications, number of injections for cure and patients satisfaction with the procedure were recorded. Patients were discharged home 3 to 4 hours after the procedure and followed up after one week, one month, three months and six months. Direct admission and re-admissions were recorded. The mean age of patients was 47 years. Mean procedure time was 45 minutes. All patients were cured. Mild postoprocedure pain occurred in 12 (40%), moderate pain in 14 (46%) patients and severe pain in 4 (13.3%) patients. No patient developed haematoma or local infection. One patient (3.3%) had micturition problem. Two (6.6%) patients had minimal recurrence. One injection was sufficient for cure in all patients, 28 (93%) patients were satisfied while 2 (6.6%) patients were not satisfied with this procedure. No patient was admitted in the hospital after the procedure. Aspiration and injection of tetracycline in Primary vaginal Hydrocoele of Testis in adults is safe, effective and very economical procedure. (author)

  19. P-Scan provides accuracy and repeatability in ultrasonics

    International Nuclear Information System (INIS)

    Keys, R.L.

    1987-01-01

    The P-Scan (Projection image scanning technique) is an automated ultrasonic inspection technique, developed to overcome the problems with accuracy and repeatability experienced with manual ultrasonic systems. The equipment and its applications are described. (author)

  20. Laryngotracheoesophageal Cleft Type 3 and Severe Laryngotracheomalacia; Delayed Surgical Repair, a Treatment Challenge with an Excellent Outcome

    Directory of Open Access Journals (Sweden)

    Ahmad Khaleghnejad

    Full Text Available Laryngotracheoesophageal clefts (LTEC are rare malformations which involve the upper respiratory and digestive tract. Surgical repair should be undertaken promptly to maintain a secure airway and prevent serious pulmonary aspiration. This paper reports the first case of LTEC type 3 with severe laryngotracheomalacia that was brought to Mofid children's hospital in late infancy with a poor health status. Delayed defect correction was our team strategy for the patient when she had achieved good weight gain. At the age of 22 months in collaboration with the pediatric surgical and otolaryngologist team, the repair of the laryngeal cleft was done with lateral open approach method. She was discharged with tracheostomy and gastrostomy. In the next six months follow up after the surgery tracheostomy decannulation and gastrostomy tube removal were done and the infant is now in regular follow-up. Keywords: Laryngotracheoesophageal clefts, Laryngotracheomalacia, Surgical repair

  1. Efficacy of an opposite position aspiration on resolution of pneumothorax following CT-guided lung biopsy

    Science.gov (United States)

    Zeng, L-C; Du, Y; Yang, H-F; Xie, M-G; Liao, H-Q; Zhang, Y-D; Li, L; Wang, Q; Hu, L

    2015-01-01

    Objective: To evaluate the efficacy of aspiration in an opposite position to deal with pneumothorax after CT-guided lung biopsy. Methods: A retrospective study was developed involving 210 patients with pneumothorax who had undergone CT-guided percutaneous core biopsies from January 2012 to March 2014 for various pulmonary lesions. Asymptomatic patients with minimal pneumothorax were treated conservatively. Simple manual aspiration was performed for symptomatic patients with minimal pneumothorax and for all patients with moderate to large pneumothorax. An opposite position aspiration was performed when simple manual aspiration failed. The efficacy of simple manual aspiration and the opposite position aspiration was observed. Results: Among 210 patients with pneumothorax, 128 (61.0%) asymptomatic patients with minimal pneumothorax were treated conservatively. The remaining 82 were treated with attempted simple manual aspiration. Out of these 82 patients, simple manual aspiration was successful in 58 (70.7%, 58/82) cases. The complete and partial regression rates were 17.2% (10/58) and 82.8% (48/58), respectively. In the other 24 patients (29.3%, 24/82), simple aspiration technique was ineffective. An opposite position (from prone to supine or vice versa) was applied, and a new biopsy puncture site was chosen for reaspiration. This procedure was successful in 22 patients but not in 2 patients who had to have a chest tube insertion. The complete and partial regression rates were 25.0% (6/24) and 66.7% (16/24), respectively. Applying the new method, the total effective rate of aspiration improved significantly from 70.7% (58/82) to 97.6% (80/82). Conclusion: The opposite position aspiration can be safe, effective and minimally invasive treatment for CT-guided lung biopsy-induced pneumothorax thus reducing the use of chest tube significantly. Advances in knowledge: (1) Opposite position aspiration can elevate the success rate of aspiration significantly (from 70.7% to 97

  2. Ultrasonic experiment on hydrate formation of a synthesis gas

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Shicai; Fan, Shuanshi; Liang, Deqing; Zhang, Junshe; Feng, Ziping

    2005-07-01

    The effect of ultrasonic on the induction time and formation rate of natural gas hydrates was investigated in a stainless steel cell in this study. The results show that the induction time with ultrasonic was about 1/6 of that without ultrasonic and only about 1/10 if rehydration after decomposition in water-gas system. In sodium dodecyl sulfate (SDS) solution-gas system, the critical micellar concentration (CMC) was not identified with ultrasonic. The formation rate and storage capacity of hydrate increased with increasing SDS concentration at a range of 0 to 800ppm. However, the increase was insignificant as the SDS concentration increased from 600 to 800ppm, (Author)

  3. Selective Bioparticle Retention and Characterization in a Chip-Integrated Confocal Ultrasonic Cavity

    DEFF Research Database (Denmark)

    Svennebring, J.; Manneberg, O.; Skafte-Pedersen, Peder

    2009-01-01

    We demonstrate selective retention and positioning of cells or other bioparticles by ultrasonic manipulation in a microfluidic expansion chamber during microfluidic perfusion. The chamber is designed as a confocal ultrasonic resonator for maximum confinement of the ultrasonic force field at the c......We demonstrate selective retention and positioning of cells or other bioparticles by ultrasonic manipulation in a microfluidic expansion chamber during microfluidic perfusion. The chamber is designed as a confocal ultrasonic resonator for maximum confinement of the ultrasonic force field...... sample feeding, a set of several manipulation functions performed in series is demonstrated: sample bypass-injection-aggregation and retention-positioning. Finally, we demonstrate transillumination microscopy imaging Of Ultrasonically trapped COS-7 cell aggregates. Biotechnol. Bioeng. 2009;103: 323-328....

  4. Defect detection and sizing in ultrasonic imaging

    International Nuclear Information System (INIS)

    Moysan, J.; Benoist, P.; Chapuis, N.; Magnin, I.

    1991-01-01

    This paper introduces imaging processing developed with the SPARTACUS system in the field of ultrasonic testing. The aim of the imaging processing is to detect and to separate defects echoes from background noise. Image segmentation and particularities of ultrasonic images are the base of studied methods. 4 figs.; 6 refs [fr

  5. Attitudes and factors contributing to attrition in Canadian surgical specialty residency programs.

    Science.gov (United States)

    Adams, Simon; Ginther, David Nathan; Neuls, Evan; Hayes, Paul

    2017-08-01

    We recently studied attrition in Canadian general surgical programs; however, there are no data on whether residents enrolled in other surgical residencies harbour the same intents as their general surgical peers. We sought to determine how many residents in surgical disciplines in Canada consider leaving their programs and why. An anonymous survey was administered to all residents in 9 surgical disciplines in Canada. Significance of association was determined using the Pearson χ2 test. The Canadian Post-MD Education Registry (CAPER) website was used to calculate the response rate. We received 523 responses (27.6% response rate). Of these respondents, 140 (26.8%) were either "somewhat" or "seriously" considering leaving their program. Residents wanting to pursue additional fellowship training and those aspiring to an academic career were significantly less likely to be considering changing specialties ( p = 0.003 and p = 0.005, respectively). Poor work-life balance and fear of unemployment/underemployment were the top reasons why residents would change specialty (55.5% and 40.8%, respectively), although the reasons cited were not significantly different between those considering changing and those who were not ( p = 0.64). Residents who were considering changing programs were significantly less likely to enjoy their work and more likely to cite having already invested too much time to change as a reason for continuing ( p work-life balance and limited employment prospects. Efforts to educate prospective residents about the reality of the surgical lifestyle and to optimize employment prospects may improve completion rates.

  6. MRI study for CT-guided stereotactic aspiration of intracerebral hematoma

    International Nuclear Information System (INIS)

    Takahashi, Toshie; Okada, Hitoshi; Kaneko, Uichi; Nishino, Akiko; Ueno, Shinji; Owada, Yuji.

    1994-01-01

    Twenty-five patients with acute hypertensive intracerebral hematomas, diagnosed by computed tomography (CT), underwent CT-guided stereotactic aspiration. Magnetic resonance (MR) images were obtained immediately before aspiration, using T 1 -weighted (TR=500 msec, TE=15 msec) and T 2 -weighted (TR=2500 msec, TE=120 msec) sequences and a 0.5 Tesla MR system. On the basis of the MR images the hematomas were divided into peripheral, central, and core segments. The signal intensities were divided into seven grades based on the comparison with white matter. The sequential changes in each segment on the MR images were evaluated, and the ratio of hematoma removal vs. size of residual hematoma was assessed by preoperative MR imaging and pre-and post-operative CT. The hematomas were located in the putamen in 13 cases, the thalamus in 8, combined in 2, and subcortex in 2. The hematomas, targeted in their centers, were evacuated by the aspiration procedure alone, 1 to 12 days after onset (day 0=day of onset). The results were as follows : 1) The proportion of hematomas removed was high after day 4. 2) Sequential T 1 -weighted images showed that the peripheral segments gradually increased in signal intensity, appearing as high-intensity rings that gradually filled and could be easily aspirated. 3) In those cases in which sequential T 2 -weighted images showed the central segments gradually increasing in signal intensity, the hematomas were easily aspirated if the signal was either iso-intense or hyper-intense. 4) Several hematomas had a core that appeared as a high intensity signal on T1-weighted images and as a low intensity signal on T 2 -weighted images; these hematomas could not be aspirated. (author)

  7. Reproducibility problems of in-service ultrasonic testing results

    International Nuclear Information System (INIS)

    Honcu, E.

    1974-01-01

    The reproducibility of the results of ultrasonic testing is the basic precondition for its successful application in in-service inspection of changes in the quality of components of nuclear power installations. The results of periodic ultrasonic inspections are not satisfactory from the point of view of reproducibility. Regardless, the ultrasonic pulse-type method is suitable for evaluating the quality of most components of nuclear installations and often the sole method which may be recommended for inspection with regard to its technical and economic aspects. (J.B.)

  8. Percutaneous CT-guided sacroiliac joint sampling for infection: aspiration, biopsy, and technique.

    Science.gov (United States)

    Knipp, David; Simeone, F Joseph; Nelson, Sandra B; Huang, Ambrose J; Chang, Connie Y

    2018-04-01

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning.

  9. Percutaneous CT-guided sacroiliac joint sampling for infection. Aspiration, biopsy, and technique

    Energy Technology Data Exchange (ETDEWEB)

    Knipp, David; Simeone, F.J.; Huang, Ambrose J.; Chang, Connie Y. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Nelson, Sandra B. [Massachusetts General Hospital, Infectious Disease Unit, Department of Medicine, Boston, MA (United States)

    2018-04-15

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning. (orig.)

  10. Further Investigations on Simultaneous Ultrasonic Coal Flotation

    Directory of Open Access Journals (Sweden)

    Safak Gokhan Ozkan

    2017-09-01

    Full Text Available This study investigates the flotation performance of a representative hard coal slime sample (d80 particle size of minus 0.2 mm obtained from the Prosper-Haniel coal preparation plant located in Bottrop, Germany. Flotation was carried out with a newly designed flotation cell refurbished from an old ultrasonic cleaning bath (2.5 L volume equipped with a single frequency (35 kHz and two different power levels (80–160 W and a sub-aeration-type flotation machine operating at a stable impeller speed (1200 rpm and air rate (2.5 L/min. The reagent combination for conventional and simultaneous ultrasonic coal flotation tests was Ekofol-440 at variable dosages (40–300 g/t with controlling water temperature (20–25 °C at natural pH (6.5–7.0. The batch coal flotation results were analyzed by comparing the combustible recovery (% and separation efficiency (% values, taking mass yield and ash concentrations of the froths and tailings into account. It was found that simultaneous ultrasonic coal flotation increased yield and recovery values of the floated products with lower ash values than the conventional flotation despite using similar reagent dosages. Furthermore, particle size distribution of the ultrasonically treated and untreated coals was measured. Finely distributed coal particles seemed to be agglomerated during the ultrasonic treatment, while ash-forming slimes were removed by hydrodynamic cavitation.

  11. Parathyroid aspiration directed by angiography: an alternative to venous sampling

    International Nuclear Information System (INIS)

    Krudy, A.G.; Doppman, J.L.; Marx, S.J.; Norton, J.A.; Spiegel, A.M.; Santora, A.C. II; Aurbach, G.D.

    1984-01-01

    Not all parathyroid glands can be visualized by CT or ultrasound and, therefore, cannot be aspirated using these techniques. The authors report the localization of a parathyroid gland by arteriography and needle aspiration under fluoroscopic guidance. This technique can be used to confirm a diagnosis of hypervascular parathyroid tissue that cannot otherwise be confirmed

  12. Total bilirubin in nasogastric aspirates: A potential new indicator of ...

    African Journals Online (AJOL)

    Background: The aim of our study was to investigate if total bilirubin (T-bil), amylase (Amy), and sodium (Na) in nasogastric (NG) aspirates can refl ect gastrointestinal motility reliably. Materials and Methods: NG aspirates from all laparotomies lasting more than 150 min in children less than 12 months old were studied for 3 ...

  13. Development and application of the ultrasonic technologies in nuclear engineering

    International Nuclear Information System (INIS)

    Lebedev, Nikolay; Krasilnikov, Dmitry; Vasiliev, Albert; Dubinin, Gennady; Yurmanov, Viktor

    2012-09-01

    Efficiency of some traditional chemical technologies in different areas could be significantly increased by adding ultrasonic treatment. For example, ultrasonic treatment was found to improve make-up water systems, decontamination procedures, etc. Improvement of traditional chemical technologies with implementation of ultrasonic treatment has allowed to significantly reducing water waste, including harmful species and radioactive products. The report shows the examples of the recent ultrasonic technology development and application in Russian nuclear engineering. They are as follows: - Preliminary cleaning of surfaces of in-pile parts (e.g. control sensors) prior to their assemblage and welding - Decontamination of grounds and metal surfaces of components with a complex structure -Decrease in sliding friction between fuel rods and grids during VVER reactor fuel assembly manufacturing -Removal of deposits from reactor fuel surfaces in VVER-440s -Increasing the density and strength of pressed sintered items while making fuel pellets and fuel elements, especially mixed-oxide fuel Surface cleanness is very important for the fuel assembly manufacturing, especially prior to welding. An ultrasonic technology for surface cleaning (from graphite and other lubricants, oxides etc.) was developed and implemented. The ultrasonic cleaning is applicable to the parts having both simple shape and different holes. Ultrasonic technology has allowed to improve the surface quality and environmental safety. Ultrasonic treatment appears to be expedient to intensify the chemical decontamination of solid radioactive waste from grounds of different fractions to metallic components. Ultrasonic treatment reduces the decontamination process duration up to 100 times as much. Excellent decontamination factor was received even for the ground fractions below 1 mm. It should be noted that alternative decontamination techniques (e.g. hydraulic separation) are poorly applicable for such ground

  14. An inverse method for crack characterization from ultrasonic B-Scan images

    International Nuclear Information System (INIS)

    Faur, M.; Roy, O.; Benoist, PH.; Morisseau, PH.

    1996-01-01

    Concern has been expressed about the capabilities of performing non destructive evaluation (NDE) of flaws located near to the outer surface in nuclear pressurized water reactor (PWR) vessels. The ultrasonic examination of PWR is accomplished from the inside with ultrasonic focused transducers working in the pulse echo mode. By recording the echoes as a function of time, the Ascan representation may be obtained. Many ultrasonic flaw detectors used for NDE are based on the simple Ascan concept involving measuring a time interval called 'time of flight'. By combining the Ascan concept synchronized transducer scanning, one can produce Bscan images that are two dimensional descriptions of the flaw interaction with the ultrasonic field. In the following, the flaw is assumed to be an axially oriented crack (the most serious flaw to be found in a pressurized component). In the case of the outer surface cracks (OSC's), analyzing and interpreting ultrasonic Ascan images become difficult because of the various reflections of the ultrasonic beam on the crack and on the outer surface (the so-called corner effect). Methods for automatic interpretation of ultrasonic experimental data are currently under investigation. In this paper, we present an inverse method for determining the geometrical characteristics of OSC's from ultrasonic Bscan images. The direct model used for the inversion procedure predicts synthetic Bscan images of ultrasonic examination of blocks containing planar defects interrogated by focused probes. (authors)

  15. Ultrasonic calibration assembly

    International Nuclear Information System (INIS)

    1981-01-01

    Ultrasonic transducers for in-service inspection of nuclear reactor vessels have several problems associated with them which this invention seeks to overcome. The first is that of calibration or referencing a zero start point for the vertical axis of transducer movement to locate a weld defect. The second is that of verifying the positioning (vertically or at a predetermined angle). Thirdly there is the problem of ascertaining the speed per unit distance in the operating medium of the transducer beam prior to the actual inspection. The apparatus described is a calibration assembly which includes a fixed, generally spherical body having a surface for reflecting an ultrasonic beam from one of the transducers which can be moved until the reflection from the spherical body is the highest amplitude return signal indicating radial alignment from the body. (U.K.)

  16. Very high temperature ultrasonic thermometer

    International Nuclear Information System (INIS)

    Jorzik, E.

    1983-01-01

    An ultrasonic thermometer comprises an electric pulse transducer head, a pulse transmission line, a notched sensor wire attached to and extending along the axis of said transmission line and a sheath enclosing the transmission line and the sensor wire, a portion of the interior face of the sheath being covered by a stuffing material along at least the length of the notched part of the sensor wire, such that contact between the sensor wire and the stuffing material does not substantially give rise to reflection of an ultrasonic pulse at the point of contact. (author)

  17. Ultrasonically assisted drilling of rocks

    Science.gov (United States)

    Mikhailova, N. V.; Onawumi, P. Y.; Roy, A.; Silberschmidt, V. V.

    2018-05-01

    Conventional drilling of rocks can generate significant damage in the drilled material; a material layer is often split off a back surface of a sample during drilling, negatively affecting its strength. To improve finish quality, ultrasonically assisted drilling (UAD) was employed in two rocks - sandstone and marble. Damage areas in both materials were reduced in UAD when compared to conventional drilling. Reductions in a thrust force and a torque reduction were observed only for UAD in marble; ultrasonic assistance in sandstone drilling did not result in improvements in this regard.

  18. Ultrasonic control of ceramic membrane fouling by particles: effect of ultrasonic factors.

    Science.gov (United States)

    Chen, Dong; Weavers, Linda K; Walker, Harold W

    2006-07-01

    Ultrasound at 20 kHz was applied to a cross-flow ultrafiltration system with gamma-alumina membranes in the presence of colloidal silica particles to systematically investigate how ultrasonic factors affect membrane cleaning. Based on imaging of the ultrasonic cavitation region, optimal cleaning occurred when the membrane was outside but close to the cavitation region. Increasing the filtration pressure increased the compressive forces driving cavitation collapse and resulted in fewer cavitation bubbles absorbing and scattering sound waves and increasing sound wave penetration. However, an increased filtration pressure also resulted in greater permeation drag, and subsequently less improvement in permeate flux compared to low filtration pressure. Finally, pulsed ultrasound with short pulse intervals resulted in permeate flux improvement close to that of continuous sonication.

  19. C-Scan Performance Test of Under-Sodium ultrasonic Waveguide Sensor in Sodium

    International Nuclear Information System (INIS)

    Joo, Young Sang; Bae, Jin Ho; Kim, Jong Bum

    2011-01-01

    Reactor core and in-vessel structures of a sodium-cooled fast (SFR) are submerged in opaque liquid sodium in the reactor vessel. The ultrasonic inspection techniques should be applied for observing the in-vessel structures under hot liquid sodium. Ultrasonic sensors such as immersion sensors and rod-type waveguide sensors have developed in order to apply under-sodium viewing of the in-vessel structures of SFR. Recently the novel plate-type ultrasonic waveguide sensor has been developed for the versatile application of under-sodium viewing in SFR. In previous studies, the ultrasonic waveguide sensor module was designed and manufactured, and the feasibility study of the ultrasonic waveguide sensor was performed. To improve the performance of the ultrasonic waveguide sensor in the under-sodium application, a new concept of ultrasonic waveguide sensors with a Be coated SS304 plate is suggested for the effective generation of a leaky wave in liquid sodium and the non-dispersive propagation of A 0 -mode Lamb wave in an ultrasonic waveguide sensor. In this study, the C-scan performance of the under-sodium ultrasonic waveguide sensor in sodium has been investigated by the experimental test in sodium. The under-sodium ultrasonic waveguide sensor and the sodium test facility with a glove box system and a sodium tank are designed and manufactured to carry out the performance test of under-sodium ultrasonic waveguide sensor in sodium environment condition

  20. Liquid ultrasonic flow meters for crude oil measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kalivoda, Raymond J.; Lunde, Per

    2005-07-01

    Liquid ultrasonic flow meters (LUFMs) are gaining popularity for the accurate measurement of petroleum products. In North America the first edition of the API standard ''Measurement of liquid hydrocarbons by ultrasonic flow meters using transit time technology'' was issued in February 2005. It addresses both refined petroleum products and crude oil applications. Its field of application is mainly custody transfer applications but it does provide general guidelines for the installation and operation of LUFM's other applications such as allocation, check meters and leak detection. As with all new technologies performance claims are at times exaggerated or misunderstood and application knowledge is limited. Since ultrasonic meters have no moving parts they appear to have fewer limitations than other liquid flow meters. Liquids ultrasonic flow meters, like turbine meters, are sensitive to fluid properties. It is increasingly more difficult to apply on high viscosity products then on lighter hydrocarbon products. Therefore application data or experience on the measurement of refined or light crude oil may not necessarily be transferred to measuring medium to heavy crude oils. Before better and more quantitative knowledge is available on how LUFMs react on different fluids, the arguments advocating reduced need for in-situ proving and increased dependency on laboratory flow calibration (e.g. using water instead of hydrocarbons) may be questionable. The present paper explores the accurate measurement of crude oil with liquid ultrasonic meters. It defines the unique characteristics of the different API grades of crude oils and how they can affect the accuracy of the liquid ultrasonic measurement. Flow testing results using a new LUFM design are discussed. The paper is intended to provide increased insight into the potentials and limitations of crude oil measurement using ultrasonic flow meters. (author) (tk)

  1. A study on Computer-controlled Ultrasonic Scanning Device

    International Nuclear Information System (INIS)

    Huh, H.; Park, C. S.; Hong, S. S.; Park, J. H.

    1989-01-01

    Since the nuclear power plants in Korea have been operated in 1979, the nondestructive testing (NDT) of pressure vessels and/or piping welds plays an important role for maintaining the safety and integrity of the plants. Ultrasonic method is superior to the other NDT method in the viewpoint of the detectability of small flaw and accuracy to determine the locations, sizes, orientations, and shapes. As the service time of the nuclear power plants is increased, the radiation level from the components is getting higher. In order to get more quantitative and reliable results and secure the inspector from the exposure to high radiation level, automation of the ultrasonic equipment has been one of the important research and development(R and D) subject. In this research, it was attempted to visualize the shape of flaws presented inside the specimen using a Modified C-Scan technique. In order to develop Modified C-Scan technique, an automatic ultrasonic scanner and a module to control the scanner were designed and fabricated. IBM-PC/XT was interfaced to the module to control the scanner. Analog signals from the SONIC MARK II were digitized by Analog-Digital Converter(ADC 0800) for Modified C-Scan display. A computer program has been developed and has capability of automatic data acquisition and processing from the digital data, which consist of maximum amplitudes in each gate range and locations. The data from Modified C-Scan results was compared with shape from artificial defects using the developed system. Focal length of focused transducer was measured. The automatic ultrasonic equipment developed through this study is essential for more accurate, reliable, and repeatable ultrasonic experiments. If the scanner are modified to meet to appropriate purposes, it can be applied to automation of ultrasonic examination of nuclear power plants and helpful to the research on ultrasonic characterization of the materials

  2. Aspiration pneumonia of mineral oil: a case report

    International Nuclear Information System (INIS)

    Malheiros, Noemia Reis; Costa Praxedes, Marcia da; Machado, Dianne Mello; Marchiori, Edson

    1995-01-01

    The authors report a case of 14 month-old boy with clinical features of dyspnea, cough and acrocyanosis following aspiration of mineral oil used in the treatment of partial small bowel obstruction by Ascaris lumbricoides. A chest roentgenogram was reported as extensive bilateral confluent consolidation that showed progressive improvement and the presence of a bilateral infiltration. The diagnosis of aspiration pneumonia of mineral oil was confirmed by lung biopsy. Radiological and anatomo pathological aspects are presented as well as a review of the medical literature about the case. (author). 6 refs., 3 figs

  3. Chemical coloring on stainless steel by ultrasonic irradiation.

    Science.gov (United States)

    Cheng, Zuohui; Xue, Yongqiang; Ju, Hongbin

    2018-01-01

    To solve the problems of high temperature and non-uniformity of coloring on stainless steel, a new chemical coloring process, applying ultrasonic irradiation to the traditional chemical coloring process, was developed in this paper. The effects of ultrasonic frequency and power density (sound intensity) on chemical coloring on stainless steel were studied. The uniformity of morphology and colors was observed with the help of polarizing microscope and scanning electron microscopy (SEM), and the surface compositions were characterized by X-ray photoelectric spectroscopy (XPS), meanwhile, the wear resistance and the corrosion resistance were investigated, and the effect mechanism of ultrasonic irradiation on chemical coloring was discussed. These results show that in the process of chemical coloring on stainless steel by ultrasonic irradiation, the film composition is the same as the traditional chemical coloring, and this method can significantly enhance the uniformity, the wear and corrosion resistances of the color film and accelerate the coloring rate which makes the coloring temperature reduced to 40°C. The effects of ultrasonic irradiation on the chemical coloring can be attributed to the coloring rate accelerated and the coloring temperature reduced by thermal-effect, the uniformity of coloring film improved by dispersion-effect, and the wear and corrosion resistances of coloring film enhanced by cavitation-effect. Ultrasonic irradiation not only has an extensive application prospect for chemical coloring on stainless steel but also provides an valuable reference for other chemical coloring. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Simulation of the Two-Phase Liquid – Gas Flow through Ultrasonic Transceivers Application in Ultrasonic Tomography

    Directory of Open Access Journals (Sweden)

    Zulkarnay Zakaria

    2010-01-01

    Full Text Available In this paper, ultrasonic transmission mode tomography was used to visualize the two phase liquid/gas flow in a pipe/vessel. The sensing element consists of 8, 16 and 32 units ultrasonic transceivers were used to cover the pipe cross-section at different time. The motivation of this paper is to analyze the optimum numbers of transceivers which can give the best performance in providing better image of the two phase liquid/gas flow. This paper also details the development of the system including the ultrasonic transduction circuits, the electronic measurement circuits, the data acquisition system and the image reconstruction techniques. Ten conditions of liquid-gas flow have been simulated. The system was found capable of visualizing the internal characteristics and provides the concentration profile for the corresponding liquid and gas phases while the 32 transceivers has provided the best image for the ten conditions applied.

  5. Method and system having ultrasonic sensor movable by translation device for ultrasonic profiling of weld samples

    Science.gov (United States)

    Panyard, James; Potter, Timothy; Charron, William; Hopkins, Deborah; Reverdy, Frederic

    2010-04-06

    A system for ultrasonic profiling of a weld sample includes a carriage movable in opposite first and second directions. An ultrasonic sensor is coupled to the carriage to move over the sample as the carriage moves. An encoder determines the position of the carriage to determine the position of the sensor. A spring is connected at one end of the carriage. Upon the carriage being moved in the first direction toward the spring such that the carriage and the sensor are at a beginning position and the spring is compressed the spring decompresses to push the carriage back along the second direction to move the carriage and the sensor from the beginning position to an ending position. The encoder triggers the sensor to take the ultrasonic measurements of the sample when the sensor is at predetermined positions while the sensor moves over the sample between the beginning and positions.

  6. Experiences in using ultrasonic holography with numerical and optical reconstruction

    International Nuclear Information System (INIS)

    Schmitz, V.; Wosnitza, M.

    1978-01-01

    At present, ultrasonic holography can resolve and image faults of 1 mm and more and with distances of one ultrasonic wavelength. The main field of application is for thick-walled structural components. Depending on the expected orientation, test probe arrangements as in standard ultrasonic testing are chosen. (orig./RW) [de

  7. Improvement of solar ethanol distillation using ultrasonic waves

    Directory of Open Access Journals (Sweden)

    Jaruwat Jareanjit

    2016-08-01

    Full Text Available This report presents a study on the use of ultrasonic waves in solar ethanol distillation to investigate the performance of ultrasonic waves at a frequency of 30 kHz and at 100 Watts that were installed in the inlet area of a 10-litre distillation tank. Based on the non-continuous distillation process (batch distillation, the experiment demonstrated that using ultrasonic waves in solar ethanol distillation caused the average concentration of hourly distilled ethanol to be higher than that of a normal system (solar ethanol distillation without ultrasonic wave at the same or higher distillation rate and hourly distillation volume. The ultrasonic wave was able to enhance the separation of ethanol from the solution (water-ethanol mixture through solar distillation. The amount of pure ethanol product from each distilled batch was clearly larger than the amount of product obtained from a normal system when the initial concentration of ethanol was lower than 50%v/v (% by volume, where an average of approximately 40% and 20% are obtained for an initial ethanol concentration of 10%v/v and 30%v/v, respectively. Furthermore, the distillation rate varied based on the solar radiation value.

  8. Youth self-formation and the 'capacity to aspire': The itinerant ...

    African Journals Online (AJOL)

    The article employs the lenses of 'aspiration', 'space', and 'technologies of self' to present the argument that his 'capacity to aspire' has to be understood on the basis of his active self-formation and disciplining, accumulated across the itinerant spaces of his life. The aim of this article is to open a window onto how young ...

  9. A rare constellation of empyema, lung abscess, and mediastinal abscess as a complication of endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Huang, Chun-Ta; Chen, Chung-Yu; Ho, Chao-Chi; Yu, Chong-Jen

    2011-07-01

    The introduction of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) brought about significant advancement in the field of bronchoscopy. The major indications for EBUS-TBNA are lung cancer staging and diagnosis of mediastinal lymphadenopathy. This procedure is minimally invasive and cost saving, and no complications have been described in large-scale studies. In this report, we present a case of empyema, lung abscess, and mediastinal abscess that developed in a patient undergoing EBUS-TBNA; the patient subsequently recovered uneventfully after aggressive surgical debridement and antimicrobial therapy. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  10. Failed fuel rod detection method by ultrasonic wave

    International Nuclear Information System (INIS)

    Takamatsu, Masatoshi; Muraoka, Shoichi; Ono, Yukio; Yasojima, Yujiro.

    1990-01-01

    Ultrasonic wave signals sent from an ultrasonic receiving element are supplied to an evaluation circuit by way of a gate. A table for gate opening and closing timings at the detecting position in each of the fuel rods in a fuel assembly is stored in a memory. A fuel rod is placed between an ultrasonic transmitting element and the receiving element to determine the positions of the transmitting element and the receiving element by positional sensors. The opening and closing timings at the positions corresponding to the result of the detection are read out from the table, and the gates are opened and closed by the timing. This can introduce the ultrasonic wave signals transmitted through a control rod always to the evaluation circuit passing through the gate. Accordingly, the state of failure of the fuel rod can be detected accurately. (I.N.)

  11. Assessing bimanual performance in brain tumor resection with NeuroTouch, a virtual reality simulator.

    Science.gov (United States)

    Alotaibi, Fahad E; AlZhrani, Gmaan A; Mullah, Muhammad A S; Sabbagh, Abdulrahman J; Azarnoush, Hamed; Winkler-Schwartz, Alexander; Del Maestro, Rolando F

    2015-03-01

    Validated procedures to objectively measure neurosurgical bimanual psychomotor skills are unavailable. The NeuroTouch simulator provides metrics to determine bimanual performance, but validation is essential before implementation of this platform into neurosurgical training, assessment, and curriculum development. To develop, evaluate, and validate neurosurgical bimanual performance metrics for resection of simulated brain tumors with NeuroTouch. Bimanual resection of 8 simulated brain tumors with differing color, stiffness, and border complexity was evaluated. Metrics assessed included blood loss, tumor percentage resected, total simulated normal brain volume removed, total tip path lengths, maximum and sum of forces used by instruments, efficiency index, ultrasonic aspirator path length index, coordination index, and ultrasonic aspirator bimanual forces ratio. Six neurosurgeons and 12 residents (6 senior and 6 junior) were evaluated. Increasing tumor complexity impaired resident bimanual performance significantly more than neurosurgeons. Operating on black vs glioma-colored tumors resulted in significantly higher blood loss and lower tumor percentage, whereas altering tactile cues from hard to soft decreased resident tumor resection. Regardless of tumor complexity, significant differences were found between neurosurgeons, senior residents, and junior residents in efficiency index and ultrasonic aspirator path length index. Ultrasonic aspirator bimanual force ratio outlined significant differences between senior and junior residents, whereas coordination index demonstrated significant differences between junior residents and neurosurgeons. The NeuroTouch platform incorporating the simulated scenarios and metrics used differentiates novice from expert neurosurgical performance, demonstrating NeuroTouch face, content, and construct validity and the possibility of developing brain tumor resection proficiency performance benchmarks.

  12. Ultrasonic weld testing.

    Science.gov (United States)

    1970-12-01

    The study was broken down into two phases. Phase I consisted of a laboratory investigation of test specimens to determine the reliability of the ultrasonic equipment and testing procedure. Phase II was a field study where the knowledge, skills and ab...

  13. Cooperation guided by the coexistence of imitation dynamics and aspiration dynamics in structured populations

    Science.gov (United States)

    Xu, Kuangyi; Li, Kun; Cong, Rui; Wang, Long

    2017-02-01

    In the framework of the evolutionary game theory, two fundamentally different mechanisms, the imitation process and the aspiration-driven dynamics, can be adopted by players to update their strategies. In the former case, individuals imitate the strategy of a more successful peer, while in the latter case individuals change their strategies based on a comparison of payoffs they collect in the game to their own aspiration levels. Here we explore how cooperation evolves for the coexistence of these two dynamics. Intriguingly, cooperation reaches its lowest level when a certain moderate fraction of individuals pick aspiration-level-driven rule while the others choose pairwise comparison rule. Furthermore, when individuals can adjust their update rules besides their strategies, either imitation dynamics or aspiration-driven dynamics will finally take over the entire population, and the stationary cooperation level is determined by the outcome of competition between these two dynamics. We find that appropriate synergetic effects and moderate aspiration level boost the fixation probability of aspiration-driven dynamics most effectively. Our work may be helpful in understanding the cooperative behavior induced by the coexistence of imitation dynamics and aspiration dynamics in the society.

  14. System and technique for ultrasonic determination of degree of cooking

    Energy Technology Data Exchange (ETDEWEB)

    Bond, Leonard J [Richland, WA; Diaz, Aaron A [W. Richland, WA; Judd, Kayte M [Richland, WA; Pappas, Richard A [Richland, WA; Cliff, William C [Richland, WA; Pfund, David M [Richland, WA; Morgen, Gerald P [Kennewick, WA

    2007-03-20

    A method and apparatus are described for determining the doneness of food during a cooking process. Ultrasonic signal are passed through the food during cooking. The change in transmission characteristics of the ultrasonic signal during the cooking process is measured to determine the point at which the food has been cooked to the proper level. In one aspect, a heated fluid cooks the food, and the transmission characteristics along a fluid-only ultrasonic path provides a reference for comparison with the transmission characteristics for a food-fluid ultrasonic path.

  15. Effect of acoustic softening on the thermal-mechanical process of ultrasonic welding.

    Science.gov (United States)

    Chen, Kunkun; Zhang, Yansong; Wang, Hongze

    2017-03-01

    Application of ultrasonic energy can reduce the static stress necessary for plastic deformation of metallic materials to reduce forming load and energy, namely acoustic softening effect (ASE). Ultrasonic welding (USW) is a rapid joining process utilizing ultrasonic energy to form a solid state joint between two or more pieces of metals. Quantitative characterization of ASE and its influence on specimen deformation and heat generation is essential to clarify the thermal-mechanical process of ultrasonic welding. In the present work, experiments were set up to found out mechanical behavior of copper and aluminum under combined effect of compression force and ultrasonic energy. Constitutive model was proposed and numerical implemented in finite element model of ultrasonic welding. Thermal-mechanical analysis was put forward to explore the effect of ultrasonic energy on the welding process quantitatively. Conclusions can be drawn that ASE increases structural deformation significantly, which is beneficial for joint formation. Meanwhile, heat generation from both frictional work and plastic deformation is slightly influenced by ASE. Based on the proposed model, relationship between ultrasonic energy and thermal-mechanical behavior of structure during ultrasonic welding was constructed. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. An ultrasonic waveguide for nuclear power plants

    International Nuclear Information System (INIS)

    Watkins, R.D.; Gillespie, A.B.; Deighton, M.O.; Pike, R.B.

    1983-01-01

    The value of ultrasonic techniques in nuclear plants is well established. However, in most cases nuclear power plants present an extremely hostile environment for an ultrasonic transducer. The paper presents a novel technique for introducing an ultrasound into hostile liquid environments using a new form of ultrasonic waveguide. Using this approach, a standard transducer arrangement is sited in a hospitable area and conveys the ultrasound along the guide to the required beam-emission collection position. The design of a single-mode ultrasonic waveguide is described. The ultrasound is conveyed along a stainless steel strip of rectangular cross-section. The transference of energy between the strip and the liquid is achieved through a highly efficient mode-conversion process. This process overcomes the usual problems of mis-match of acoustic impedances of stainless steel and liquids, and also produces a highly collimated beam of ultrasound. Tests of a 10-m-long waveguide using these techniques are described, achieving signal-to-noise ratios in the region of 40 dB. (author)

  17. Energy-Based Analysis of Ultrasonically Assisted Turning

    Directory of Open Access Journals (Sweden)

    G.A. Volkov

    2011-01-01

    Full Text Available The process of ultrasonically-assisted turning (UAT is a superposition of vibration of a cutting tool on its standard movement in conventional turning (CT. The former technique has several advantages compared with the latter, one of the main being a significant decrease in the level of cutting forces. In this paper the effects observed in UAT are analysed employing ideas of dynamic fracture mechanics. The active stage of loading duration depends heavily on ultrasonic frequency and the cutting speed; he application of the fracture criterion based on the notion of incubation time makes it possible to calculate a dependence of this duration on its threshold amplitude. An estimation of energy, necessary to create a threshold pulse in the material, is made by solving the contact Hertz problem. The obtained time dependence of energy has a marked minimum. Thus, the existence of energy-efficient loading duration is demonstrated. This explains the decrease in the cutting force resulting from superimposed ultrasonic vibration. The obtained results are in agreement with experiments on ultrasonic assisted machining of aluminium and Inconel 718 alloy.

  18. Wear reduction through piezoelectrically-assisted ultrasonic lubrication

    International Nuclear Information System (INIS)

    Dong, Sheng; J Dapino, Marcelo

    2014-01-01

    Traditional lubricants are undesirable in harsh aerospace environments and certain automotive applications. Ultrasonic vibrations can be used to reduce and modulate the effective friction coefficient between two sliding surfaces. This paper investigates the relationship between friction force reduction and wear reduction in ultrasonically lubricated surfaces. A pin-on-disc tribometer is modified through the addition of a piezoelectric transducer which vibrates the pin at 22 kHz in the direction perpendicular to the rotating disc surface. Friction and wear metrics including volume loss, surface roughness, friction forces and apparent stick-slip effects are measured without and with ultrasonic vibrations at three different sliding velocities. SEM imaging and 3D profilometry are used to characterize the wear surfaces and guide model development. Over the range of speeds considered, ultrasonic vibrations reduce the effective friction force up to 62% along with a wear reduction of up to 49%. A simple cube model previously developed to quantify friction force reduction is implemented which describes wear reduction within 15% of the experimental data. (paper)

  19. Dog-Bone Horns for Piezoelectric Ultrasonic/Sonic Actuators

    Science.gov (United States)

    Sherrit, Stewart; Bar-Cohen, Yoseph; Chang, Zensheu; Bao, Xiaoqi

    2007-01-01

    A shape reminiscent of a dog bone has been found to be superior to other shapes for mechanical-amplification horns that are components of piezoelectrically driven actuators used in a series of related devices denoted generally as ultrasonic/sonic drill/corers (USDCs). The first of these devices was reported in Ultrasonic/Sonic Drill/Corers With Integrated Sensors (NPO-20856), NASA Tech Briefs, Vol. 25, No. 1 (January 2001), page 38. The dog-bone shape was conceived especially for use in a more recent device in the series, denoted an ultrasonic/ sonic gopher, that was described in Ultrasonic/Sonic Mechanisms for Drilling and Coring (NPO-30291), NASA Tech Briefs, Vol. 27, No. 9 (September 2003), page 65. The figure shows an example of a dog-bone-shaped horn and other components of an ultrasonic gopher. Prerequisite to a meaningful description of this development is an unavoidably lengthy recapitulation of the principle of operation of a USDC and, more specifically, of the ultrasonic/sonic gopher as described previously in NASA Tech Briefs. The ultrasonic actuator includes a stack of piezoelectric rings, the horn, a metal backing, and a bolt that connects the aforementioned parts and provides compressive pre-strain to the piezoelectric stack to prevent breakage of the rings during extension. The stack of piezoelectric rings is excited at the resonance frequency of the overall ultrasonic actuator. Through mechanical amplification by the horn, the displacement in the ultrasonic vibration reaches tens of microns at the tip of the horn. The horn hammers an object that is denoted the free mass because it is free to move longitudinally over a limited distance between hard stops: The free mass bounces back and forth between the ultrasonic horn and a tool bit (a drill bit or a corer). Because the longitudinal speed of the free mass is smaller than the longitudinal speed of vibration of the tip of the horn, contact between the free mass and the horn tip usually occurs at a

  20. An investigation of the associations between contingent self-worth and aspirations among Iranian university students.

    Science.gov (United States)

    Sabzehara, Milad; Ferguson, Yuna Lee; Sarafraz, Mehdi Reza; Mohammadi, Mostafa

    2014-01-01

    This study investigated the novel associations between intrinsic and extrinsic aspirations and internal and external domains of contingent self-worth among a sample of 502 Iranian university students. We found a meaningful pattern showing that intrinsic aspirations were positively associated with internal domains, whereas extrinsic aspirations were positively associated with external domains. Our survey data also suggested that the factor structure of the Aspiration Index, as well as the factor structure of the Contingencies of Self-Worth Scale in our Iranian sample were consistent with factor structures of foreign samples. Finally, the types of aspirations and domains of contingencies of self-worth meaningfully predicted variables related to well-being, confirming previous research. We discuss the nature of the associations between the aspirations and the domains of contingent self-worth.

  1. High quantum yield ZnO quantum dots synthesizing via an ultrasonication microreactor method.

    Science.gov (United States)

    Yang, Weimin; Yang, Huafang; Ding, Wenhao; Zhang, Bing; Zhang, Le; Wang, Lixi; Yu, Mingxun; Zhang, Qitu

    2016-11-01

    Green emission ZnO quantum dots were synthesized by an ultrasonic microreactor. Ultrasonic radiation brought bubbles through ultrasonic cavitation. These bubbles built microreactor inside the microreactor. The photoluminescence properties of ZnO quantum dots synthesized with different flow rate, ultrasonic power and temperature were discussed. Flow rate, ultrasonic power and temperature would influence the type and quantity of defects in ZnO quantum dots. The sizes of ZnO quantum dots would be controlled by those conditions as well. Flow rate affected the reaction time. With the increasing of flow rate, the sizes of ZnO quantum dots decreased and the quantum yields first increased then decreased. Ultrasonic power changed the ultrasonic cavitation intensity, which affected the reaction energy and the separation of the solution. With the increasing of ultrasonic power, sizes of ZnO quantum dots first decreased then increased, while the quantum yields kept increasing. The effect of ultrasonic temperature on the photoluminescence properties of ZnO quantum dots was influenced by the flow rate. Different flow rate related to opposite changing trend. Moreover, the quantum yields of ZnO QDs synthesized by ultrasonic microreactor could reach 64.7%, which is higher than those synthesized only under ultrasonic radiation or only by microreactor. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Wavelet Analysis of Ultrasonic Echo Waveform and Application to Nondestructive Evaluation

    International Nuclear Information System (INIS)

    Park, Ik Keun; Park, Un Su; Ahn, Hyung Keun; Kwun, Sook In; Byeon, Jai Won

    2000-01-01

    Recently, advanced signal analysis which is called 'time-frequency analysis' has been used widely in nondestructive evaluation applications. Wavelet transform(WT) and Wigner Distribution are the most advanced techniques for processing signals with time-varying spectra. Wavelet analysis method is an attractive technique for evaluation of material characterization nondestructively. Wavelet transform is applied to the time-frequency analysis of ultrasonic echo waveform obtained by an ultrasonic pulse-echo technique. In this study, the feasibility of noise suppression of ultrasonic flaw signal and frequency-dependent ultrasonic group velocity and attenuation coefficient using wavelet analysis of ultrasonic echo waveform have been verified experimentally. The Gabor function is adopted the analyzing wavelet. The wavelet analysis shows that the variations of ultrasonic group velocity and attenuation coefficient due to the change of material characterization can be evaluated at each frequency. Furthermore, to assure the enhancement of detectability and new sizing performance, both computer simulated results and experimental measurements using wavelet signal processing are used to demonstrate the effectiveness of the noise suppression of ultrasonic flaw signal obtained from austenitic stainless steel weld including EDM notch

  3. Automated ultrasonic inspection using PULSDAT

    International Nuclear Information System (INIS)

    Naybour, P.J.

    1992-01-01

    PULSDAT (Portable Ultrasonic Data Acquisition Tool) is a system for recording the data from single probe automated ultrasonic inspections. It is one of a range of instruments and software developed by Nuclear Electric to carry out a wide variety of high quality ultrasonic inspections. These vary from simple semi-automated inspections through to multi-probe, highly automated ones. PULSDAT runs under the control of MIPS software, and collects data which is compatible with the GUIDE data display system. PULSDAT is therefore fully compatible with Nuclear Electric's multi-probe inspection systems and utilises all the reliability and quality assurance of the software. It is a rugged, portable system that can be used in areas of difficult access. The paper discusses the benefits of automated inspection and gives an outline of the main features of PULSDAT. Since April 1990 PULSDAT has been used in several applications within Nuclear Electric and this paper presents two examples: the first is a ferritic set-through nozzle and the second is an austenitic fillet weld. (Author)

  4. Correlación entre la localización del lente intraocular, según biomicroscopia ultrasónica,y diferentes parámetros quirúrgicos en pacientes operados de catarata Correlation between the location of the intraocular lens according to ultrasonic biomicroscopy and several surgical parameters in patients operated from cataract

    Directory of Open Access Journals (Sweden)

    Eneida de la C Pérez Candelaria

    2010-01-01

    Full Text Available OBJETIVO: Determinar la correlación entre la localización del lente intraocular en cámara posterior por biomicroscopia ultrasónica, diferentes parámetros quirúrgicos en pacientes operados de catarata. MÉTODOS: Se realizó un estudio descriptivo, prospectivo y transversal en el Instituto Cubano de Oftalmología «Ramón Pando Ferrer», durante el período de enero a junio del 2007. Se estudiaron variables como: edad, sexo, etiología de la catarata, técnica quirúrgica, localización del lente intraocular según biomicroscopia ultrasónica, así como complicaciones transoperatorias y posoperatorias. RESULTADOS: El 79 % de todos los pacientes operados tenían entre 60 y 79 años de edad y algo más de la mitad correspondió al sexo femenino con un 59 %. La catarata senil fue la etiología que predominó con un 74 % y en el 68 % de los casos el lente se localizó por biomicroscopia ultrasónica en el saco capsular. En los ojos donde el lente intraocular se localizó fuera del saco, la proporción de complicaciones transoperatorias y posoperatorias fueron significativamente mayoritarias, mientras que en los ojos donde el lente intraocular se encontraba en el saco, la mayoría no presentó complicaciones transoperatorias ni posoperatorias. CONCLUSIONES: Las diferencias entre las distintas localizaciones del lente intraocular se encontraron con significación estadística en el tipo de catarata, la presencia de complicaciones transoperatorias y posoperatorias, sin embargo, no se encontró relación estadística significativa entre la localización del lente intraocular con la técnica quirúrgica utilizada.OBJECTIVE: To determine the correlation between the location of the intraocular lens in the posterior chamber using ultrasonic biomicroscopy and the different surgical parameters in patients operated from cataract. METHODS: A prospective, descriptive and cross-sectional study was carried out in "Ramón Pando Ferrer" Cuban Institute of

  5. Development of phased-array ultrasonic testing probe

    International Nuclear Information System (INIS)

    Kawanami, Seiichi; Kurokawa, Masaaki; Taniguchi, Masaru; Tada, Yoshihisa

    2001-01-01

    Phased-array ultrasonic testing was developed for nondestructive evaluation of power plants. Phased-array UT scans and focuses an ultrasonic beam to inspect areas difficult to inspect by conventional UT. We developed a highly sensitive piezoelectric composite, and designed optimized phased-array UT probes. We are applying our phased-array UT to different areas of power plants. (author)

  6. Automated ultrasonic testing--capabilities, limitations and methods

    International Nuclear Information System (INIS)

    Beller, L.S.; Mikesell, C.R.

    1977-01-01

    The requirements for precision and reproducibility of ultrasonic testing during inservice inspection of nuclear reactors are both quantitatively and qualitatively more severe than most current practice in the field can provide. An automated ultrasonic testing (AUT) system, which provides a significant advancement in field examination capabilities, is described. Properties of the system, its application, and typical results are discussed

  7. Ultrasonic guided wave for monitoring corrosion of steel bar

    Science.gov (United States)

    Liu, Xi; Qin, Lei; Huang, Bosheng

    2018-01-01

    Steel corrosion of reinforced concrete structures has become a serious problem all over the word. In this paper, the work aims at monitoring steel corrosion using ultrasonic guided wave (UGW). Ultrasonic guided wave monitoring is a dynamic and non-destructive testing technology. The advantages of ultrasonic guided wave monitoring for reinforcement corrosion are real-time, online and continuous. In addition, it can judge the different stages of steel bar corrosion, which achieved non-destructive detection.

  8. Desired Destinations of Homeless Women: Realizing Aspirations Within the Context of Homelessness.

    Science.gov (United States)

    Biederman, Donna J; Forlan, Nicole

    2016-08-01

    Despite recent decreases, homelessness remains a substantial problem in the United States. Homelessness is associated with poor health, and homeless women experience earlier mortality than their housed counterparts. Understanding the aspirations of homeless women may offer service providers avenues for intervention to increase well-being among this vulnerable population. This study, a secondary analysis of transcribed interviews (n = 20), provides insight into the aspirations of homeless women. Opportunities for service providers to intervene on these aspirations within the context of homelessness are offered.

  9. Aspiration rate following chemoradiation for head and neck cancer: An underreported occurrence

    International Nuclear Information System (INIS)

    Nguyen, Nam P.; Frank, Cheryl; Moltz, Candace C.; Vos, Paul; Smith, Herbert J.; Bhamidipati, Prabhakar V.; Karlsson, Ulf; Nguyen, Phuc D.; Alfieri, Alan; Nguyen, Ly M.; Lemanski, Claire; Chan, Wayne; Rose, Sue; Sallah, Sabah

    2006-01-01

    Background and purpose: We would like to assess the prevalence of aspiration before and following chemoradiation for head and neck cancer. Patients and methods: We reviewed retrospectively the Modified Barium Swallow (MBS) in 63 patients who underwent concurrent chemotherapy and radiation for head and neck cancer. MBS was performed prior to treatment to determine the need for immediate gastrostomy tube placement. MBS was repeated following treatment to assess the safety of oral feeding prior to removal of tube feeding. All patients were cancer free at the time of the swallowing study. No patient had surgery. Dysphagia severity was graded on a scale of 1-7. Tube feedings were continued if patients were diagnosed to have severe aspiration (grade 6-7) or continued weight loss. Patients with abnormal swallow (grade 3-7) received swallowing therapy following MBS. Results: Before treatment, there were 18 grade 1, 18 grade 2, 9 grade 3, 8 grade 4, 3 grade 5, 3 grade 6, and 4 grade 7. Following chemoradiation, at a median follow-up of 2 months (1-10 months), one patient had grade 1, eight patients had grade 2, nine patients had grade 3, eight patients had grade 4, 13 patients had grade 5, seven patients had grade 6, and 11 patients had grade 7. Six patients died from aspiration pneumonia (one before, three during, and two post-treatment), and did not have the second MBS. Overall, 37/63 (59%) patients developed aspiration, six of them (9%) fatal. If we excluded the 10 patients who had severe aspiration at diagnosis and the six patients who died from pneumonia, the prevalence of severe aspiration was 33% (21/63). Conclusions: Aspiration remained a significant morbidity following chemoradiation for head and neck cancer. Its prevalence is underreported in the literature because of its often silent nature. Diagnostic studies such as MBS should be part of future head and neck cancer prospective studies to assess the prevalence of aspiration, and for rehabilitation

  10. Gas ultrasonic flow rate measurement through genetic-ant colony optimization based on the ultrasonic pulse received signal model

    Science.gov (United States)

    Hou, Huirang; Zheng, Dandan; Nie, Laixiao

    2015-04-01

    For gas ultrasonic flowmeters, the signals received by ultrasonic sensors are susceptible to noise interference. If signals are mingled with noise, a large error in flow measurement can be caused by triggering mistakenly using the traditional double-threshold method. To solve this problem, genetic-ant colony optimization (GACO) based on the ultrasonic pulse received signal model is proposed. Furthermore, in consideration of the real-time performance of the flow measurement system, the improvement of processing only the first three cycles of the received signals rather than the whole signal is proposed. Simulation results show that the GACO algorithm has the best estimation accuracy and ant-noise ability compared with the genetic algorithm, ant colony optimization, double-threshold and enveloped zero-crossing. Local convergence doesn’t appear with the GACO algorithm until -10 dB. For the GACO algorithm, the converging accuracy and converging speed and the amount of computation are further improved when using the first three cycles (called GACO-3cycles). Experimental results involving actual received signals show that the accuracy of single-gas ultrasonic flow rate measurement can reach 0.5% with GACO-3 cycles, which is better than with the double-threshold method.

  11. Actively adjustable step-type ultrasonic horns in longitudinal vibration

    Science.gov (United States)

    Lin, Shuyu; Guo, Hao; Xu, Jie

    2018-04-01

    Actively adjustable longitudinal step-type ultrasonic horns are proposed and studied. The horn is composed of a traditional ultrasonic horn and piezoelectric material. In practical applications, this kind of step-type ultrasonic horn is mechanically excited by an ultrasonic transducer and the piezoelectric material is connected to an adjustable electric impedance. In this research, the effects of the electric impedance and of the location of the piezoelectric material on the performance of the horn are studied. It is shown that when the electric resistance is increased, the resonance frequency of the horn is increased; the displacement magnification is increased when the piezoelectric material is located in the large end and decreased when the piezoelectric material is located in the small end of the horn. The displacement magnification for the piezoelectric material in the large end is larger than that for the piezoelectric material in the small end of the horn. Some step-type ultrasonic horns are designed and manufactured; the resonance frequency and the displacement magnification are measured by means of POLYTEC Laser Scanning vibrometer. It is shown that the theoretical resonance frequency and the displacement magnification are in good agreement with the measured results. It is concluded that by means of the insertion of the piezoelectric material in the longitudinal horn, the horn performance can be adjusted by changing the electric impedance and the location of the piezoelectric material in the horn. It is expected that this kind of adjustable ultrasonic horns can be used in traditional and potential ultrasonic technologies where the vibrational performance adjustment is needed.

  12. Mid-IR laser ultrasonic testing for fiber reinforced plastics

    Science.gov (United States)

    Kusano, Masahiro; Hatano, Hideki; Oguchi, Kanae; Yamawaki, Hisashi; Watanabe, Makoto; Enoki, Manabu

    2018-04-01

    Ultrasonic testing is the most common method to detect defects in materials and evaluate their sizes and locations. Since piezo-electric transducers are manually handled from point to point, it takes more costs for huge products such as airplanes. Laser ultrasonic testing (LUT) is a breakthrough technique. A pulsed laser generates ultrasonic waves on a material surface due to thermoelastic effect or ablation. The ultrasonic waves can be detected by another laser with an interferometer. Thus, LUT can realize instantaneous inspection without contacting a sample. A pulse laser with around 3.2 μm wavelength (in the mid-IR range) is more suitable to generate ultrasonic waves for fiber reinforced plastics (FRPs) because the light is well absorbed by the polymeric matrix. On the other hand, such a laser is not available in the market. In order to emit the mid-IR laser pulse, we came up with the application of an optical parametric oscillator and developed an efficient wavelength conversion device by pumping a compact Nd:YAG solid-state laser. Our mid-IR LUT system is most suitable for inspection of FRPs. The signal-to-noise ratio of ultrasonic waves generated by the mid-IR laser is higher than that by the Nd:YAG laser. The purpose of the present study is to evaluate the performance of the mid-IR LUT system in reflection mode. We investigated the effects of the material properties and the laser properties on the generated ultrasonic waves. In addition, C-scan images by the system were also presented.

  13. Pars-plana fluid aspiration for positive vitreous cavity pressure in anterior segment surgeries

    Directory of Open Access Journals (Sweden)

    Thomas Kuriakose

    2018-01-01

    Full Text Available Positive vitreous pressure due to misdirection of aqueous or choroidal effusion leads to shallowing of the anterior chamber (AC before or during anterior segment surgeries. This shallow AC if not addressed makes surgery difficult and increases the risk of surgical complications. Methods to prevent and manage this condition described in literature are not without problems. We describe a minimally invasive technique of passing a 30G needle through the pars-plana to aspirate misdirected fluid from vitreous cavity either as a prophylaxis just before surgery or during it, thereby decreasing positive vitreous pressure. This technique, used in 12 eyes, seems to be effective in patients with angle-closure glaucoma, malignant glaucoma, and per-operative sudden increase in vitreous pressure during surgery. Small-incision surgeries are ideally suited for this procedure. This minimally invasive technique is simple to perform and complications are unlikely to be more than what is seen with intravitreal injections.

  14. Aspirations of young people living in disadvantaged areas in Denmark

    DEFF Research Database (Denmark)

    Frørup, Anna Kathrine; Jensen, Niels Rosendal

    2017-01-01

    how young people's (living in a socially disadvantaged area) possibilities, aspirations and demands are raised, strengthened, transformed or put aside and in what way they feel participating within different local programmes.......how young people's (living in a socially disadvantaged area) possibilities, aspirations and demands are raised, strengthened, transformed or put aside and in what way they feel participating within different local programmes....

  15. Method of case hardening depth testing by using multifunctional ultrasonic testing instrument

    International Nuclear Information System (INIS)

    Salchak, Y A; Sednev, D A; Ardashkin, I B; Kroening, M

    2015-01-01

    The paper describes usability of ultrasonic case hardening depth control applying standard instrument of ultrasonic inspections. The ultrasonic method of measuring the depth of the hardened layer is proposed. Experimental series within the specified and multifunctional ultrasonic equipment are performed. The obtained results are compared with the results of a referent method of analysis. (paper)

  16. A Case of Bone Aspiration Mimicking Asthma in an Adult Patient

    Directory of Open Access Journals (Sweden)

    Servet Kayhan

    2014-03-01

    Full Text Available Foreign body aspiration is an urgent condition that requires immediate diagnosis and intervention. It is generally seen in children and in elderly patients with neurological problems and rarely seen in healthy adults. There may be some clinical signs and symptoms in patients with foreign body aspiration from mild to severe; such as cough, shortness of breath and respiratory arrest. A 52-year-old woman applied to our clinic with the complaints of cough and shortness of breath, and she was misdiagnosed and treated as asthma for three months. The chest radiograph showed heterogenous opacity in the right paracardiac region, computerized tomography revealed the foreign body aspiration in right main bronchus and peripheric pneumonia. Flexible bronchoscopy examination was processed and the foreign body was excluded safely with the aim of crocodile forceps. Foreign body aspiration should be kept in the mind in a adult patient with a sudden onset of asthma like disorder.  

  17. Proceedings of the specialists' meeting on reliability of the ultrasonic inspection of austenitic materials

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1980-07-01

    The contributions of this meeting addressed several topics: the fundamentals of ultrasonic examination of austenitic materials (effect of anisotropy on propagation, improvement of ultrasonic testing to thick bimetallic welds, aspects of the ultrasonic testing of austenitic steel structures, utilization of a Fisher linear discriminant function in intergranular stress corrosion cracking or IGSCC detection, case of coarse grain austenitic welds, efforts of the Argonne National Laboratory), instruments and methods (longitudinal wave ultrasonic inspection, Grass echo suppression technique during the ultrasonic inspection of fuel cladding tubes, inspections of fillet and butt welds, improvement by signal averaging techniques, multiple bearing angle crack detector for cladded pipes examinations, flow-to-grain echo enhancement by split-spectrum processing, ultrasonic imaging techniques, ultrasonic inspection of pipe weldments for IGSCC), industrial practice (ultrasonic testing techniques for fabrication and in-service inspection, experiences in ultrasonic examination of austenitic steel components, experience and practice on nuclear piping in Spain, detection of underclad defects, sizing of cracks perpendicular to stainless overlay), and reliability (survey of ultrasonic testing in austenitic weld material, examination of electron beam welds, factors affecting the reliability of ultrasonic examination, detectability of IGSCC, ultrasonic inspection reliability for primary piping systems)

  18. Proceedings of the specialists' meeting on reliability of the ultrasonic inspection of austenitic materials

    International Nuclear Information System (INIS)

    1980-01-01

    The contributions of this meeting addressed several topics: the fundamentals of ultrasonic examination of austenitic materials (effect of anisotropy on propagation, improvement of ultrasonic testing to thick bimetallic welds, aspects of the ultrasonic testing of austenitic steel structures, utilization of a Fisher linear discriminant function in intergranular stress corrosion cracking or IGSCC detection, case of coarse grain austenitic welds, efforts of the Argonne National Laboratory), instruments and methods (longitudinal wave ultrasonic inspection, Grass echo suppression technique during the ultrasonic inspection of fuel cladding tubes, inspections of fillet and butt welds, improvement by signal averaging techniques, multiple bearing angle crack detector for cladded pipes examinations, flow-to-grain echo enhancement by split-spectrum processing, ultrasonic imaging techniques, ultrasonic inspection of pipe weldments for IGSCC), industrial practice (ultrasonic testing techniques for fabrication and in-service inspection, experiences in ultrasonic examination of austenitic steel components, experience and practice on nuclear piping in Spain, detection of underclad defects, sizing of cracks perpendicular to stainless overlay), and reliability (survey of ultrasonic testing in austenitic weld material, examination of electron beam welds, factors affecting the reliability of ultrasonic examination, detectability of IGSCC, ultrasonic inspection reliability for primary piping systems)

  19. Elemental diets may reduce the risk of aspiration pneumonia in bedridden gastrostomy-fed patients.

    Science.gov (United States)

    Horiuchi, Akira; Nakayama, Yoshiko; Sakai, Ryosei; Suzuki, Manabu; Kajiyama, Masashi; Tanaka, Naoki

    2013-05-01

    Our clinical experience suggested that elemental diets were associated with a reduction in aspiration pneumonia among bedridden patients with percutaneous endoscopic gastrostomy (PEG). We compared the effects of elemental and standard liquid diets on the risk of clinical aspiration pneumonia and gastric emptying in bedridden patients receiving PEG feedings. Study 1: consecutive bedridden PEG patients received elemental diets or standard liquid diets in the same fashion. The frequency of defecation, diet aspirated from the trachea, and aspiration pneumonia during hospitalization were prospectively recorded. Study 2: a randomized, crossover trial using elemental or standard liquid diets containing (13)C sodium acetate as a tracer given to bedridden PEG patients who had experienced aspiration pneumonia. (13)C breath tests were performed to estimate gastric emptying. Study 1: 127 patients were enrolled, 60 with elemental and 67 with standard liquid diets. The diet was aspirated from the trachea in none (0%) with the elemental diet vs. 8 (11.9%) with standard liquid diets (P=0.0057); aspiration pneumonia developed none with the elemental diet vs. 5 (7.5%) with standard liquid diets (P=0.031) (number needed to treat 14, 95% confidence interval 7-85). Study 2: 19 patients were enrolled. The elemental diet was associated with a significant increase in the 10, 30 or 50% emptying (excretion) time (Pbedridden PEG patients. They may be preferred for bedridden PEG patients especially who have experienced aspiration pneumonia. Properly performed randomized-controlled trials are needed to prove this potential benefit.

  20. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.

    Science.gov (United States)

    Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus

    2011-01-01

    Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.

  1. Nurses' leadership self-efficacy, motivation, and career aspirations.

    Science.gov (United States)

    Cziraki, Karen; Read, Emily; Spence Laschinger, Heather K; Wong, Carol

    2018-02-05

    Purpose This paper aims to test a model examining precursors and outcomes of nurses' leadership self-efficacy, and their aspirations to management positions. Design/methodology/approach A cross-sectional survey of 727 registered nurses across Canada was conducted. Structural equation modelling using Mplus was used to analyse the data. Findings Results supported the hypothesized model: χ 2 (312) = 949.393; CFI = 0.927; TLI = 0.919; RMSEA = 0.053 (0.049-0.057); SRMR 0.044. Skill development opportunities ( ß = 0.20), temporary management roles ( ß = 0.12) and informal mentoring ( ß = 0.11) were significantly related to nurses' leadership self-efficacy, which significantly influenced motivation to lead ( ß = 0.77) and leadership career aspirations ( ß = 0.23). Motivation to lead was significantly related to leadership career aspirations ( ß = 0.50). Practical implications Nurses' leadership self-efficacy is an important determinant of their motivation and intention to pursue a leadership career. Results suggest that nurses' leadership self-efficacy can be influenced by providing opportunities for leadership mastery experiences and mentorship support. Leadership succession planning should include strategies to enhance nurses' leadership self-efficacy and increase front-line nurses' interest in leadership roles. Originality value With an aging nurse leader workforce, it is important to understand factors influencing nurses' leadership aspirations to develop and sustain nursing leadership capacity. This research study makes an important contribution to the nursing literature by showing that nurses' leadership self-efficacy appears to be an important determinant of their motivation to lead and desire to pursue a career as a nurse leader.

  2. Utility of Eating Assessment Tool-10 in Predicting Aspiration in Patients with Unilateral Vocal Fold Paralysis.

    Science.gov (United States)

    Zuniga, Steven A; Ebersole, Barbara; Jamal, Nausheen

    2018-03-01

    Objective Examine the incidence of penetration/aspiration in patients with unilateral vocal fold immobility and investigate the relationship with self-reported perception of dysphagia. Study Design Case series with chart review. Setting Academic cancer center. Subjects and Methods Adult patients with unilateral vocal fold immobility diagnosed between 2014 and 2016 were reviewed. Patients were stratified into an aspiration group and a nonaspiration group using objective findings on flexible endoscopic evaluation of swallowing, as scored using Rosenbek's Penetration Aspiration Scale. Objective findings were compared to patient perception of dysphagia. Bivariate linear correlation analysis was performed to evaluate correlation between Eating Assessment Tool-10 scores and presence of aspiration. Tests of diagnostic accuracy were calculated to investigate the predictive value of Eating Assessment Tool-10 scores >9 on aspiration risk. Results Of the 35 patients with new-onset unilateral vocal fold immobility were evaluated, 25.7% (9/35) demonstrated tracheal aspiration. Mean ± SD Eating Assessment Tool-10 scores were 19.2 ± 13.7 for aspirators and 7.0 ± 7.8 for nonaspirators ( P = .016). A statistically significant correlation was demonstrated between increasing Eating Assessment Tool-10 scores and Penetration Aspiration Scale scores ( r = 0.511, P = .002). Diagnostic accuracy analysis for aspiration risk in patients with an Eating Assessment Tool-10 score >9 revealed a sensitivity of 77.8% and a specificity of 73.1%. Conclusion Patient perception of swallowing difficulty may have utility in predicting aspiration risk. An EAT-10 of >9 in patients with unilateral vocal fold immobility may portend up to a 5 times greater risk of aspiration. Routine swallow testing to assess for penetration/aspiration may be indicated in patients with unilateral vocal fold immobility.

  3. Measurement of Oxygen Desaturation Is Not Useful for the Detection of Aspiration in Dysphagic Stroke Patients

    Directory of Open Access Journals (Sweden)

    Thomas Marian

    2017-03-01

    Full Text Available Background: Dysphagia is one of the most dangerous symptoms of acute stroke. Various screening tools have been suggested for the early detection of this condition. In spite of conflicting results, measurement of oxygen saturation (SpO2 during clinical swallowing assessment is still recommended by different national guidelines as a screening tool with a decline in SpO2 ≥2% usually being regarded as a marker of aspiration. This paper assesses the sensitivity of SpO2 measurements for the evaluation of aspiration risk in acute stroke patients. Methods: Fifty acute stroke patients with moderate to severe dysphagia were included in this study. In all patients, fiberoptic endoscopic evaluation of swallowing (FEES was performed according to a standardised protocol. Blinded to the results of FEES, SpO2 was monitored simultaneously. The degree of desaturation during/after swallows with aspiration was compared to the degree of desaturation during/after swallows without aspiration in a swallow-to-swallow analysis of each patient. To minimise potential confounders, every patient served as their control. Results: In each subject, a swallow with and a swallow without aspiration were analysed. Overall, aspiration seen in FEES was related to a minor decline in SpO2 (mean SpO2 without aspiration 95.54 ± 2.7% vs. mean SpO2 with aspiration 95.28 ± 2.7%. However, a significant desaturation ≥2% occurred only in 5 patients during/after aspiration. There was no correlation between aspiration/dysphagia severity or the amount of aspirated material and SpO2 levels. Conclusions: According to this study, measurement of oxygen desaturation is not a suitable screening tool for the detection of aspiration in stroke patients.

  4. Ultrasonic testing using time of flight diffraction technique (TOFD)

    International Nuclear Information System (INIS)

    Khurram Shahzad; Ahmad Mirza Safeer Ahmad; Muhammad Asif Khan

    2009-04-01

    This paper describes the ultrasonic testing using Time Flight Diffraction (TOFD) Technique for welded samples having different types and sizes of defects. TOFD is a computerized ultrasonic system, able to scan, store and evaluate indications in terms of location, through thickness and length in a more easy and convenient. Time of Flight Diffraction Technique (TOFD) is more fast and easy technique for ultrasonic testing as we can examine a weld i a single scan along the length of the weld with two probes known as D-scan. It shows the image of the complete weld with the defect information. The examinations were performed on carbon steel samples used for ultrasonic testing using 70 degree probes. The images for different type of defects were obtained. (author)

  5. Ultrasonic-resonator-combined apparatus for purifying nuclear aerosol particles

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Suxia; Zhang, Quanhu; Li, Sufen; Chen, Chen; Su, Xianghua [Xi' an Hi-Tech Institute, Xi' an (China)

    2017-12-15

    The radiation hazards of radionuclides in the air arising from the storage room of nuclear devices to the operators cannot be ignored. A new ultrasonic-resonator-combined method for purifying nuclear aerosol particles is introduced. To remove particles with diameters smaller than 0.3 μm, an ultrasonic chamber is induced to agglomerate these submicron particles. An apparatus which is used to purify the nuclear aerosol particles is described in the article. The apparatus consists of four main parts: two filtering systems, an ultrasonic chamber and a high-pressure electrostatic precipitator system. Finally, experimental results demonstrated the effectiveness of the implementation of the ultrasonic resonators. The feasibility of the method is proven by its application to the data analysis of the experiments.

  6. Ultrasonic Generation and Optimization for EMAT

    International Nuclear Information System (INIS)

    Jian, X.; Dixon, Steve; Edwards, Rachel S.

    2005-01-01

    A model for transient ultrasonic wave generation by EMATs in non-magnetic metals is presented. It combines analytical solutions currently available and FEM to calculate ultrasonic bulk and Rayleigh waves generated by the EMAT. Analytical solutions are used as they can be calculated quickly on a standard mathematical computer package. Calculations agree well with the experimental measurement. The model can be used to optimize EMAT design, and has explained some of the results from our previous published measurements

  7. Longitudinal ultrasonic waves dispersion in bars

    International Nuclear Information System (INIS)

    Suarez Antola, R.

    2001-01-01

    The exhibition intends to review some aspects of the propagation of the longitudinal ultrasonic pulses shortly in bars of traverse section uniform.Aspects they are part of the denominated geometric dispersion of the pulses.This phenomenon It can present like an additional complication in the ultrasonic essay of low frequency of thin pieces in structures and machines but takes place former ex professed in some applications of the wave guides been accustomed to in the prosecution of signs

  8. Ultrasonic hot powder compaction of Ti-6Al-4V.

    Science.gov (United States)

    Abedini, Rezvan; Abdullah, Amir; Alizadeh, Yunes

    2017-07-01

    Power ultrasonic has been recently employed in a wide variety of manufacturing processes among which ultrasonic assisted powder compaction is a promising powder materials processing technique with significant industrial applications. The products manufactured by the powder metallurgy commonly consist of residual porosities, material impurities, structural non-homogeneities and residual stress. In this paper, it is aimed to apply power ultrasonic to the hot consolidation process of Ti-6Al-4V titanium alloy powder in order to improve mechanical properties. To do this, the effects of ultrasonic power and process temperature and pressure were considered and then deeply studied through a series of experiments. It was shown that the addition of ultrasonic vibration leads to a significant improvement in the consolidation performance and the mechanical strength of the fabricated specimens. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Detecting accuracy of flaws by manual and automatic ultrasonic inspections

    International Nuclear Information System (INIS)

    Iida, K.

    1988-01-01

    As the final stage work in the nine year project on proving tests of the ultrasonic inspection technique applied to the ISI of LWR plants, automatic ultrasonic inspection tests were carried out on EDM notches, surface fatigue cracks, weld defects and stress corrosion cracks, which were deliberately introduced in full size structural components simulating a 1,100 MWe BWR. Investigated items are the performance of a newly assembled automatic inspection apparatus, detection limit of flaws, detection resolution of adjacent collinear or parallel EDM notches, detection reproducibility and detection accuracy. The manual ultrasonic inspection of the same flaws as inspected by the automatic ultrasonic inspection was also carried out in order to have comparative data. This paper reports how it was confirmed that the automatic ultrasonic inspection is much superior to the manual inspection in the flaw detection rate and in the detection reproducibility

  10. A Miniature Probe for Ultrasonic Penetration of a Single Cell

    Directory of Open Access Journals (Sweden)

    Mingfei Xiao

    2009-05-01

    Full Text Available Although ultrasound cavitation must be avoided for safe diagnostic applications, the ability of ultrasound to disrupt cell membranes has taken on increasing significance as a method to facilitate drug and gene delivery. A new ultrasonic resonance driving method is introduced to penetrate rigid wall plant cells or oocytes with springy cell membranes. When a reasonable design is created, ultrasound can gather energy and increase the amplitude factor. Ultrasonic penetration enables exogenous materials to enter cells without damaging them by utilizing instant acceleration. This paper seeks to develop a miniature ultrasonic probe experiment system for cell penetration. A miniature ultrasonic probe is designed and optimized using the Precise Four Terminal Network Method and Finite Element Method (FEM and an ultrasonic generator to drive the probe is designed. The system was able to successfully puncture a single fish cell.

  11. A study on the development of a real-time intelligent system for ultrasonic flaw classification

    International Nuclear Information System (INIS)

    Song, Sung Jin; Kim, Hak Joon; Lee, Hyun; Lee, Seung Seok

    1998-01-01

    In spite of significant progress in research on ultrasonic pattern recognition it is not widely used in many practical field inspection in weldments. For the convenience of field application of this methodology, following four key issues have to be suitably addressed; 1) a software where the ultrasonic pattern recognition algorithm is efficiently implemented, 2) a real-time ultrasonic testing system which can capture the digitized ultrasonic flaw signal so the pattern recognition software can be applied in a real-time fashion, 3) database of ultrasonic flaw signals in weldments, which is served as a foundation of the ultrasonic pattern recognition algorithm, and finally, 4) ultrasonic features which should be invariant to operational variables of the ultrasonic test system. Presented here is the recent progress in the development of a real-time ultrasonic flaw classification by the novel combination of followings; an intelligent software for ultrasonic flaw classification in weldments, a computer-base real-time ultrasonic nondestructive evaluation system, database of ultrasonic flaw signals, and invariant ultrasonic features called 'normalized features.'

  12. Presenting hydrothorax predicts failure of needle aspiration in primary spontaneous pneumothorax.

    Science.gov (United States)

    Wu, Kwok Kei; Lui, Chun Tat; Ho, Chik Leung; Tsui, Kwok Leung; Fung, Hin Tat

    2016-06-01

    The objective was to evaluate if existence of hydrothorax in initial chest radiograph predicts treatment outcome in patients with primary spontaneous pneumothorax who received needle thoracostomy. This is a retrospective cohort study carried out from January 2011 to August 2014 in 1 public hospital in Hong Kong. All consecutive adult patients aged 18years or above who attended the emergency department with the diagnosis of primary spontaneous pneumothorax with needle aspiration performed as primary treatment were included. Age, smoking status, size of pneumothorax, previous history of pneumothorax, aspirated gas volume and presence of hydropneumothorax in initial radiograph were included in the analysis. The outcome was success or failure of the needle aspiration. Logistic regression was used to identify the predicting factors of failure of needle aspiration. There were a total of 127 patients included. Seventy-three patients (57.5%) were successfully treated with no recurrence upon discharge. Among 54 failure cases, 13 patients (10.2%) failed immediately after procedure as evident by chest radiograph and required second treatment. Forty-one patients (32.3%) failed upon subsequent chest radiographs. Multivariate logistic regression showed factors independently associated with the failure of needle aspiration, which included hydropneumothorax in the initial radiograph (odds ratio [OR]=4.47 [1.56i12.83], P=.005), previous history of pneumothorax (OR=3.92 [1.57-9.79], P=.003), and large size of pneumothorax defined as apex-to-cupola distance ≥5cm (OR=2.75 [1.21-6.26], P=.016). Hydropneumothorax, previous history of pneumothorax, and large size were independent predictors of failure of needle aspiration in treatment of primary spontaneous pneumothorax. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Research of the ultrasonic testing parts reconditioned by welding

    Directory of Open Access Journals (Sweden)

    C. Petriceanu

    2016-07-01

    Full Text Available The paper presents the results obtained following the nondestructive ultrasonic testing of crankpin shaft of a crankshaft that were reconditioned by welding. After the ultrasonic testing, the reconditioned samples were cut and subjected to visual testing and microstructure examination. When the results obtained following the nondestructive tests were analyzed, it was observed that the ultrasonic nondestructive testing method is an efficient way to determine the conformity of the areas that were reconditioned by welding.

  14. Ultrasonic-assisted manufacturing processes: Variational model and numerical simulations

    KAUST Repository

    Siddiq, Amir; El Sayed, Tamer

    2012-01-01

    We present a computational study of ultrasonic assisted manufacturing processes including sheet metal forming, upsetting, and wire drawing. A fully variational porous plasticity model is modified to include ultrasonic softening effects

  15. A capacitive ultrasonic transducer based on parametric resonance

    Science.gov (United States)

    Surappa, Sushruta; Satir, Sarp; Levent Degertekin, F.

    2017-07-01

    A capacitive ultrasonic transducer based on a parametric resonator structure is described and experimentally demonstrated. The transducer structure, which we call capacitive parametric ultrasonic transducer (CPUT), uses a parallel plate capacitor with a movable membrane as part of a degenerate parametric series RLC resonator circuit with a resonance frequency of fo. When the capacitor plate is driven with an incident harmonic ultrasonic wave at the pump frequency of 2fo with sufficient amplitude, the RLC circuit becomes unstable and ultrasonic energy can be efficiently converted to an electrical signal at fo frequency in the RLC circuit. An important characteristic of the CPUT is that unlike other electrostatic transducers, it does not require DC bias or permanent charging to be used as a receiver. We describe the operation of the CPUT using an analytical model and numerical simulations, which shows drive amplitude dependent operation regimes including parametric resonance when a certain threshold is exceeded. We verify these predictions by experiments with a micromachined membrane based capacitor structure in immersion where ultrasonic waves incident at 4.28 MHz parametrically drive a signal with significant amplitude in the 2.14 MHz RLC circuit. With its unique features, the CPUT can be particularly advantageous for applications such as wireless power transfer for biomedical implants and acoustic sensing.

  16. Ultrasonic imaging of material flaws exploiting multipath information

    Science.gov (United States)

    Shen, Xizhong; Zhang, Yimin D.; Demirli, Ramazan; Amin, Moeness G.

    2011-05-01

    In this paper, we consider ultrasonic imaging for the visualization of flaws in a material. Ultrasonic imaging is a powerful nondestructive testing (NDT) tool which assesses material conditions via the detection, localization, and classification of flaws inside a structure. Multipath exploitations provide extended virtual array apertures and, in turn, enhance imaging capability beyond the limitation of traditional multisensor approaches. We utilize reflections of ultrasonic signals which occur when encountering different media and interior discontinuities. The waveforms observed at the physical as well as virtual sensors yield additional measurements corresponding to different aspect angles. Exploitation of multipath information addresses unique issues observed in ultrasonic imaging. (1) Utilization of physical and virtual sensors significantly extends the array aperture for image enhancement. (2) Multipath signals extend the angle of view of the narrow beamwidth of the ultrasound transducers, allowing improved visibility and array design flexibility. (3) Ultrasonic signals experience difficulty in penetrating a flaw, thus the aspect angle of the observation is limited unless access to other sides is available. The significant extension of the aperture makes it possible to yield flaw observation from multiple aspect angles. We show that data fusion of physical and virtual sensor data significantly improves the detection and localization performance. The effectiveness of the proposed multipath exploitation approach is demonstrated through experimental studies.

  17. Bacteriology of aspiration pneumonia in patients with acute coma.

    Science.gov (United States)

    Lauterbach, Enise; Voss, Frederik; Gerigk, Roland; Lauterbach, Michael

    2014-12-01

    Loss of protective airway reflexes in patients with acute coma puts these patients at risk of aspiration pneumonia complicating the course of the primary disease. Available data vary considerably with regard to bacteriology, role of anaerobic bacteria, and antibiotic treatment. Our objective was to research the bacteriology of aspiration pneumonia in acute coma patients who were not pre-treated with antibiotics or hospitalized within 30 days prior to the event. We prospectively analyzed 127 patient records from adult patients admitted, intubated and ventilated to a tertiary medical intensive care unit with acute coma. Bacteriology and antibiotic resistance testing from tracheal aspirate sampled within 24 h after admission, blood cultures, ICU scores (APACHE II, SOFA), hematology, and clinical chemistry were assessed. Patients were followed up until death or hospital discharge. The majority of patients with acute coma suffered from acute cardiovascular disorders, predominantly myocardial infarction, followed by poisonings, and coma of unknown cause. In a majority of our patients, microaspiration resulted in overt infection. Most frequently S. aureus, H. influenzae, and S. pneumoniae were isolated. Anaerobic bacteria (Bacteroides spec., Fusobacteria, Prevotella spec.) were isolated from tracheal aspirate in a minority of patients, and predominantly as part of a mixed infection. Antibiotic monotherapy with a 2nd generation cephalosporin, or a 3rd generation gyrase inhibitor, was most effective in our patients regardless of the presence of anaerobic bacteria.

  18. Analysis of ultrasonic techniques for the characterization of microfiltration polymeric membranes

    International Nuclear Information System (INIS)

    Lucas, Carla S.; Baroni, Douglas B.; Costa, Antonio M.L.M.; Bittencourt, Marcelo S.Q.

    2009-01-01

    The use of polymeric membranes is extremely important in several industries such as nuclear, biotechnology, chemical and pharmaceutical. In the nuclear area, for instance, systems based on membrane separation technologies are currently being used in the treatment of radioactive liquid effluent, and new technologies using membranes are being developed at a great rate. The knowledge of the physical characteristics of these membranes, such as, pore size and the pore size distribution, is very important to the membranes separation processes. Only after these characteristics are known is it possible to determine the type and to choose a particular membrane for a specific application. In this work, two ultrasonic non destructive techniques were used to determine the porosity of membranes: pulse echo and transmission. A 25 MHz immersion transducer was used. Ultrasonic signals were acquired, for both techniques, after the ultrasonic waves passed through a microfiltration polymeric membrane of pore size of 0.45 μm and thickness of 180 μm. After the emitted ultrasonic signal crossed the membrane, the received signal brought several information on the influence of the membrane porosity in the standard signal of the ultrasonic wave. The ultrasonic signals were acquired in the time domain and changed to the frequency domain by application of the Fourier Fast Transform (FFT), thus generating the material frequency spectrum. For the pulse echo technique, the ultrasonic spectrum frequency changed after the ultrasonic wave crossed the membrane. With the transmission technique there was only a displacement of the ultrasonic signal at the time domain. (author)

  19. Nondestructive evaluation of a cermet coating using ultrasonic and eddy current techniques

    International Nuclear Information System (INIS)

    Roge, B.; Fahr, A.; Giguere, J.S.R.; McRae, K.I.

    2002-01-01

    This paper describes a series of experiments conducted to characterize cermet coatings using conventional ultrasonic and eddy current techniques as well as an ultrasonic leaky surface wave method. The results demonstrate the ability of these techniques to detect the presence of artificial defects on the surface or beneath the surface of the coating. In addition, ultrasonic tests in particular ultrasonic leaky surface waves demonstrate the ability to detect the presence of manufacturing flaws. Ultrasonic time-of-flight and eddy current quadrature measurements also show sensitivity to variations in coating thickness

  20. Reproducibility of the results in ultrasonic testing

    International Nuclear Information System (INIS)

    Chalaye, M.; Launay, J.P.; Thomas, A.

    1980-12-01

    This memorandum reports on the conclusions of the tests carried out in order to evaluate the reproducibility of ultrasonic tests made on welded joints. FRAMATOME have started a study to assess the dispersion of results afforded by the test line and to characterize its behaviour. The tests covered sensors and ultrasonic generators said to be identical to each other (same commercial batch) [fr