WorldWideScience

Sample records for ultrabright head mounted

  1. The head-mounted microscope.

    Science.gov (United States)

    Chen, Ting; Dailey, Seth H; Naze, Sawyer A; Jiang, Jack J

    2012-04-01

    Microsurgical equipment has greatly advanced since the inception of the microscope into the operating room. These advancements have allowed for superior surgical precision and better post-operative results. This study focuses on the use of the Leica HM500 head-mounted microscope for the operating phonosurgeon. The head-mounted microscope has an optical zoom from 2× to 9× and provides a working distance from 300 mm to 700 mm. The headpiece, with its articulated eyepieces, adjusts easily to head shape and circumference, and offers a focus function, which is either automatic or manually controlled. We performed five microlaryngoscopic operations utilizing the head-mounted microscope with successful results. By creating a more ergonomically favorable operating posture, a surgeon may be able to obtain greater precision and success in phonomicrosurgery. Phonomicrosurgery requires the precise manipulation of long-handled cantilevered instruments through the narrow bore of a laryngoscope. The head-mounted microscope shortens the working distance compared with a stand microscope, thereby increasing arm stability, which may improve surgical precision. Also, the head-mounted design permits flexibility in head position, enabling operator comfort, and delaying musculoskeletal fatigue. A head-mounted microscope decreases the working distance and provides better ergonomics in laryngoscopic microsurgery. These advances provide the potential to promote precision in phonomicrosurgery. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  2. Creating Gaze Annotations in Head Mounted Displays

    DEFF Research Database (Denmark)

    Mardanbeigi, Diako; Qvarfordt, Pernilla

    2015-01-01

    To facilitate distributed communication in mobile settings, we developed GazeNote for creating and sharing gaze annotations in head mounted displays (HMDs). With gaze annotations it possible to point out objects of interest within an image and add a verbal description. To create an annota- tion...

  3. Combat vehicle crew helmet-mounted display: next generation high-resolution head-mounted display

    Science.gov (United States)

    Nelson, Scott A.

    1994-06-01

    The Combat Vehicle Crew Head-Mounted Display (CVC HMD) program is an ARPA-funded, US Army Natick Research, Development, and Engineering Center monitored effort to develop a high resolution, flat panel HMD for the M1 A2 Abrams main battle tank. CVC HMD is part of the ARPA High Definition Systems (HDS) thrust to develop and integrate small (24 micrometers square pels), high resolution (1280 X 1024 X 6-bit grey scale at 60 frame/sec) active matrix electroluminescent (AMEL) and active matrix liquid crystal displays (AMLCD) for head mounted and projection applications. The Honeywell designed CVC HMD is a next generation head-mounted display system that includes advanced flat panel image sources, advanced digital display driver electronics, high speed (> 1 Gbps) digital interconnect electronics, and light weight, high performance optical and mechanical designs. The resulting dramatic improvements in size, weight, power, and cost have already led to program spin offs for both military and commercial applications.

  4. Parallax error in the monocular head-mounted eye trackers

    DEFF Research Database (Denmark)

    Mardanbeigi, Diako; Witzner Hansen, Dan

    2012-01-01

    each parameter affects the error. The optimum distribution of the error (magnitude and direction) in the field of view varies for different applications. However, the results can be used for finding the optimum parameters that are needed for designing a head-mounted gaze tracker. It has been shown...

  5. Light Field Rendering for Head Mounted Displays using Pixel Reprojection

    DEFF Research Database (Denmark)

    Hansen, Anne Juhler; Klein, Jákup; Kraus, Martin

    2017-01-01

    Light field displays have advantages over traditional stereoscopic head mounted displays, for example, because they can overcome the vergence-accommodation conflict. However, rendering light fields can be a heavy task for computers due to the number of images that have to be rendered. Since much ...

  6. Exploring Virtual Worlds With Head-Mounted Displays

    Science.gov (United States)

    Chung, James C.; Harris, Mark R.; Brooks, Frederick P.; Fuchs, Henry; Kelley, Michael T.; Hughes, John W.; Ouh-Young, Ming; Cheung, Clement; Holloway, Richard L.; Pique, Michael

    1989-09-01

    For nearly a decade the University of North Carolina at Chapel Hill has been conducting research in the use of simple head-mounted displays in "real-world" applications. Such units provide the user with non-holographic true three-dimensional information, since the kinetic depth effect, stereoscopy, and other visual cues combine to immerse the user in a "virtual world" which behaves like the real world in some respects. UNC's head-mounted display was built inexpensively from commercially available off-the-shelf components. Tracking of the the user's head position and orientation is performed by a Polhemus Navigation Sciences' 3SPACE* tracker. The host computer uses the tracking information to generate updated images corresponding to the user's new left eye and right eye views. The images are broadcast to two liquid crystal television screens (220x320 pixels) mounted on a horizontal shelf at the user's forehead. The user views these color screens through half-silvered mirrors, enabling the computer-generated image to be superimposed upon the user's real physical environment. The head-mounted display has been incorporated into existing molecular modeling and architectural applications being developed at UNC. In molecular structure studies, chemists are presented with a room-sized molecule with which they can interact in a manner more intuitive than that provided by conventional two-dimensional displays and dial boxes. Walking around and through the large molecule may provide quicker understanding of its structure, and such problems as drug-enzyme docking may be approached with greater insight. In architecture, the head-mounted display enables clients to better appreciate three-dimensional designs, which may be misinterpreted in their conventional two-dimensional form by untrained eyes. The addition of a treadmill to the system provides additional kinesthetic input into the understanding of building size and scale.

  7. Psychometric Assessment of Stereoscopic Head-Mounted Displays

    Science.gov (United States)

    2016-06-29

    Journal Article 3. DATES COVERED (From – To) Jan 2015 - Dec 2015 4. TITLE AND SUBTITLE PSYCHOMETRIC ASSESSMENT OF STEREOSCOPIC HEAD- MOUNTED DISPLAYS...to render an immersive three-dimensional constructive environment. The purpose of this effort was to quantify the impact of aircrew vision on an...simulated tasks requiring precise depth discrimination. This work will provide an example validation method for future stereoscopic virtual immersive

  8. Immersive vision assisted remote teleoperation using head mounted displays

    International Nuclear Information System (INIS)

    Vakkapatla, Veerendrababu; Singh, Ashutosh Pratap; Rakesh, V.; Rajagopalan, C.; Murugan, S.; Sai Baba, M.

    2016-01-01

    Handling and inspection of irradiated material is inevitable in nuclear industry. Hot cells are shielded radiation containment chambers equipped with master slave manipulators that facilitates remote handling. The existing methods using viewing windows and cameras for viewing the contents of hot cell to manipulate the radioactive elements have problems such as optical distortion, limited distance teleoperation, limited field of view that lead to inefficient operation. This paper presents a method of achieving immersive teleoperation to operate the master slave manipulator in hot cells by exploiting the advanced tracking and display capabilities of head mounted display devices. (author)

  9. MRTouch: Adding Touch Input to Head-Mounted Mixed Reality.

    Science.gov (United States)

    Xiao, Robert; Schwarz, Julia; Throm, Nick; Wilson, Andrew D; Benko, Hrvoje

    2018-04-01

    We present MRTouch, a novel multitouch input solution for head-mounted mixed reality systems. Our system enables users to reach out and directly manipulate virtual interfaces affixed to surfaces in their environment, as though they were touchscreens. Touch input offers precise, tactile and comfortable user input, and naturally complements existing popular modalities, such as voice and hand gesture. Our research prototype combines both depth and infrared camera streams together with real-time detection and tracking of surface planes to enable robust finger-tracking even when both the hand and head are in motion. Our technique is implemented on a commercial Microsoft HoloLens without requiring any additional hardware nor any user or environmental calibration. Through our performance evaluation, we demonstrate high input accuracy with an average positional error of 5.4 mm and 95% button size of 16 mm, across 17 participants, 2 surface orientations and 4 surface materials. Finally, we demonstrate the potential of our technique to enable on-world touch interactions through 5 example applications.

  10. "Head up and eyes out" advances in head mounted displays capabilities

    Science.gov (United States)

    Cameron, Alex

    2013-06-01

    There are a host of helmet and head mounted displays, flooding the market place with displays which provide what is essentially a mobile computer display. What sets aviators HMDs apart is that they provide the user with accurate conformal information embedded in the pilots real world view (see through display) where the information presented is intuitive and easy to use because it overlays the real world (mix of sensor imagery, symbolic information and synthetic imagery) and enables them to stay head up, eyes out, - improving their effectiveness, reducing workload and improving safety. Such systems are an enabling technology in the provision of enhanced Situation Awareness (SA) and reducing user workload in high intensity situations. Safety Is Key; so the addition of these HMD functions cannot detract from the aircrew protection functions of conventional aircrew helmets which also include life support and audio communications. These capabilities are finding much wider application in new types of compact man mounted audio/visual products enabled by the emergence of new families of micro displays, novel optical concepts and ultra-compact low power processing solutions. This papers attempts to capture the key drivers and needs for future head mounted systems for aviation applications.

  11. Using Priors to Compensate Geometrical Problems in Head-Mounted Eye Trackers

    DEFF Research Database (Denmark)

    Batista Narcizo, Fabricio; Ahmed, Zaheer; Hansen, Dan Witzner

    The use of additional information (a.k.a. priors) to help the eye tracking process is presented as an alternative to compensate classical geometrical problems in head-mounted eye trackers. Priors can be obtained from several distinct sources, such as: sensors to collect information related...... estimation specially for uncalibrated head-mounted setups....

  12. Head-Mounted Display Technology for Low Vision Rehabilitation and Vision Enhancement

    Science.gov (United States)

    Ehrlich, Joshua R.; Ojeda, Lauro V.; Wicker, Donna; Day, Sherry; Howson, Ashley; Lakshminarayanan, Vasudevan; Moroi, Sayoko E.

    2017-01-01

    Purpose To describe the various types of head-mounted display technology, their optical and human factors considerations, and their potential for use in low vision rehabilitation and vision enhancement. Design Expert perspective. Methods An overview of head-mounted display technology by an interdisciplinary team of experts drawing on key literature in the field. Results Head-mounted display technologies can be classified based on their display type and optical design. See-through displays such as retinal projection devices have the greatest potential for use as low vision aids. Devices vary by their relationship to the user’s eyes, field of view, illumination, resolution, color, stereopsis, effect on head motion and user interface. These optical and human factors considerations are important when selecting head-mounted displays for specific applications and patient groups. Conclusions Head-mounted display technologies may offer advantages over conventional low vision aids. Future research should compare head-mounted displays to commonly prescribed low vision aids in order to compare their effectiveness in addressing the impairments and rehabilitation goals of diverse patient populations. PMID:28048975

  13. Eyewear Computing – Augmenting the Human with Head-mounted Wearable Assistants (Dagstuhl Seminar 16042)

    OpenAIRE

    Bulling, Andreas; Cakmakci, Ozan; Kunze, Kai; Rehg, James M.

    2016-01-01

    The seminar was composed of workshops and tutorials on head-mounted eye tracking, egocentric vision, optics, and head-mounted displays. The seminar welcomed 30 academic and industry researchers from Europe, the US, and Asia with a diverse background, including wearable and ubiquitous computing, computer vision, developmental psychology, optics, and human-computer interaction. In contrast to several previous Dagstuhl seminars, we used an ignite talk format to reduce the time of talks to...

  14. Head mounted device for point-of-gaze estimation in three dimensions

    DEFF Research Database (Denmark)

    Hansen, Dan Witzner; Lidegaard, Morten; Krüger, Norbert

    2014-01-01

    This paper presents a fully calibrated extended geometric approach for gaze estimation in three dimensions (3D). The methodology is based on a geometric approach utilising a fully calibrated binocular setup constructed as a head-mounted system. The approach is based on utilisation of two ordinary...... in the horizontal and vertical dimensions regarding fixations. However, even though the workspace is limited, the fact that the system is designed as a head-mounted device, the workspace volume is relatively positioned to the pose of the device. Hence gaze can be estimated in 3D with relatively free head...

  15. Optical characterization of ultrabright LEDs

    International Nuclear Information System (INIS)

    Benavides, Juan Manuel; Webb, Robert H.

    2005-01-01

    Ultrabright light emitting diodes (LEDs) are a new light source for visual psychophysics and microscopy. The new LEDs are intended primarily for room and exterior illumination, and the manufacturers' specifications are adequate for that. However, we use them as light sources in situations where a more complete characterization may be useful. For one set of LEDs we have measured the radiometric intensity and its distribution in space and wavelength, and we have tested for interactions of these variables and their dependence on driver configuration. We describe techniques for making these measurements and give a link to a simple calculator for converting among radiometric and photometric measures, as well as an evaluation of the safety considerations these very bright sources demand

  16. Clinical application of a modern high-definition head-mounted display in sonography.

    Science.gov (United States)

    Takeshita, Hideki; Kihara, Kazunori; Yoshida, Soichiro; Higuchi, Saori; Ito, Masaya; Nakanishi, Yasukazu; Kijima, Toshiki; Ishioka, Junichiro; Matsuoka, Yoh; Numao, Noboru; Saito, Kazutaka; Fujii, Yasuhisa

    2014-08-01

    Because of the remarkably improved image quality and wearability of modern head-mounted displays, a monitoring system using a head-mounted display rather than a fixed-site monitor for sonographic scanning has the potential to improve the diagnostic performance and lessen the examiner's physical burden during a sonographic examination. In a preclinical setting, 2 head-mounted displays, the HMZ-T2 (Sony Corporation, Tokyo, Japan) and the Wrap1200 (Vuzix Corporation, Rochester, NY), were found to be applicable to sonography. In a clinical setting, the feasibility of the HMZ-T2 was shown by its good image quality and acceptable wearability. This modern device is appropriate for clinical use in sonography. © 2014 by the American Institute of Ultrasound in Medicine.

  17. Recent advances in head-mounted light field displays for virtual and augmented reality (Conference Presentation)

    Science.gov (United States)

    Hua, Hong

    2017-02-01

    Head-mounted light field displays render a true 3D scene by sampling either the projections of the 3D scene at different depths or the directions of the light rays apparently emitted by the 3D scene and viewed from different eye positions. They are capable of rendering correct or nearly correct focus cues and addressing the very well-known vergence-accommodation mismatch problem in conventional virtual and augmented reality displays. In this talk, I will focus on reviewing recent advancements of head-mounted light field displays for VR and AR applications. I will demonstrate examples of HMD systems developed in my group.

  18. Use cases and usability challenges for head-mounted displays in healthcare

    Directory of Open Access Journals (Sweden)

    Mentler T.

    2015-09-01

    Full Text Available In the healthcare domain, head-mounted displays (HMDs with augmented reality (AR modalities have been reconsidered for application as a result of commercially available products and the needs for using computers in mobile context. Within a user-centered design approach, interviews were conducted with physicians, nursing staff and members of emergency medical services. Additionally practitioners were involved in evaluating two different head-mounted displays. Based on these measures, use cases and usability considerations according to interaction design and information visualization were derived and are described in this contribution.

  19. The research on a novel type of the solar-blind UV head-mounted displays

    Science.gov (United States)

    Zhao, Shun-long

    2011-08-01

    Ultraviolet technology of detecting is playing a more and more important role in the field of civil application, especially in the corona discharge detection, in modern society. Now the UV imaging detector is one of the most important equipments in power equipment flaws detection. And the modern head-mounted displays (HMDs) have shown the applications in the fields of military, industry production, medical treatment, entertainment, 3D visualization, education and training. We applied the system of head-mounted displays to the UV image detection, and a novel type of head-mounted displays is presented: the solar-blind UV head-mounted displays. And the structure is given. By the solar-blind UV head-mounted displays, a real-time, isometric and visible image of the corona discharge is correctly displayed upon the background scene where it exists. The user will see the visible image of the corona discharge on the real scene rather than on a small screen. Then the user can easily find out the power equipment flaws and repair them. Compared with the traditional UV imaging detector, the introducing of the HMDs simplifies the structure of the whole system. The original visible spectrum optical system is replaced by the eye in the solar-blind UV head-mounted displays. And the optical image fusion technology would be used rather than the digital image fusion system which is necessary in traditional UV imaging detector. That means the visible spectrum optical system and digital image fusion system are not necessary. This makes the whole system cheaper than the traditional UV imaging detector. Another advantage of the solar-blind UV head-mounted displays is that the two hands of user will be free. So while observing the corona discharge the user can do some things about it. Therefore the solar-blind UV head-mounted displays can make the corona discharge expose itself to the user in a better way, and it will play an important role in corona detection in the future.

  20. Optical Head-Mounted Computer Display for Education, Research, and Documentation in Hand Surgery.

    Science.gov (United States)

    Funk, Shawn; Lee, Donald H

    2016-01-01

    Intraoperative photography and capturing videos is important for the hand surgeon. Recently, optical head-mounted computer display has been introduced as a means of capturing photographs and videos. In this article, we discuss this new technology and review its potential use in hand surgery. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. A head-mounted display system for augmented reality: Initial evaluation for interventional MRI

    International Nuclear Information System (INIS)

    Wendt, M.; Wacker, F.K.

    2003-01-01

    Purpose: To discuss the technical details of a head mounted display with an augmented reality (AR) system and to describe a first pre-clinical evaluation in interventional MRI. Method: The AR system consists of a video-see-through head mounted display (HMD), mounted with a mini video camera for tracking and a stereo pair of mini cameras that capture live images of the scene. The live video view of the phantom/patient is augmented with graphical representations of anatomical structures from MRI image data and is displayed on the HMD. The application of the AR system with interventional MRI was tested using a MRI data set of the head and a head phantom. Results: The HMD enables the user to move around and observe the scene dynamically from various viewpoints. Within a short time the natural hand-eye coordination can easily be adapted to the slightly different view. The 3D perception is based on stereo and kinetic depth cues. A circular target with a diameter of 0.5 square centimeter was hit in 19 of 20 attempts. In a first evaluation the MRI image data augmented reality scene of a head phantom allowed good planning and precise simulation of a puncture. Conclusion: The HMD in combination with AR provides a direct, intuitive guidance for interventional MR procedures. (orig.) [de

  2. Tackling the challenges of fully immersive head-mounted AR devices

    Science.gov (United States)

    Singer, Wolfgang; Hillenbrand, Matthias; Münz, Holger

    2017-11-01

    The optical requirements of fully immersive head mounted AR devices are inherently determined by the human visual system. The etendue of the visual system is large. As a consequence, the requirements for fully immersive head-mounted AR devices exceeds almost any high end optical system. Two promising solutions to achieve the large etendue and their challenges are discussed. Head-mounted augmented reality devices have been developed for decades - mostly for application within aircrafts and in combination with a heavy and bulky helmet. The established head-up displays for applications within automotive vehicles typically utilize similar techniques. Recently, there is the vision of eyeglasses with included augmentation, offering a large field of view, and being unobtrusively all-day wearable. There seems to be no simple solution to reach the functional performance requirements. Known technical solutions paths seem to be a dead-end, and some seem to offer promising perspectives, however with severe limitations. As an alternative, unobtrusively all-day wearable devices with a significantly smaller field of view are already possible.

  3. Integration Head Mounted Display Device and Hand Motion Gesture Device for Virtual Reality Laboratory

    Science.gov (United States)

    Rengganis, Y. A.; Safrodin, M.; Sukaridhoto, S.

    2018-01-01

    Virtual Reality Laboratory (VR Lab) is an innovation for conventional learning media which show us whole learning process in laboratory. There are many tools and materials are needed by user for doing practical in it, so user could feel new learning atmosphere by using this innovation. Nowadays, technologies more sophisticated than before. So it would carry in education and it will be more effective, efficient. The Supported technologies are needed us for making VR Lab such as head mounted display device and hand motion gesture device. The integration among them will be used us for making this research. Head mounted display device for viewing 3D environment of virtual reality laboratory. Hand motion gesture device for catching user real hand and it will be visualized in virtual reality laboratory. Virtual Reality will show us, if using the newest technologies in learning process it could make more interesting and easy to understand.

  4. A Survey of Calibration Methods for Optical See-Through Head-Mounted Displays

    OpenAIRE

    Grubert, Jens; Itoh, Yuta; Moser, Kenneth; Swan II, J. Edward

    2017-01-01

    Optical see-through head-mounted displays (OST HMDs) are a major output medium for Augmented Reality, which have seen significant growth in popularity and usage among the general public due to the growing release of consumer-oriented models, such as the Microsoft Hololens. Unlike Virtual Reality headsets, OST HMDs inherently support the addition of computer-generated graphics directly into the light path between a user's eyes and their view of the physical world. As with most Augmented and Vi...

  5. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display.

    Science.gov (United States)

    Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R

    2012-08-01

    A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.

  6. Cardiac and Respiratory Parameter Estimation Using Head-mounted Motion-sensitive Sensors

    Directory of Open Access Journals (Sweden)

    J. Hernandez

    2015-05-01

    Full Text Available This work explores the feasibility of using motion-sensitive sensors embedded in Google Glass, a head-mounted wearable device, to robustly measure physiological signals of the wearer. In particular, we develop new methods to use Glass’s accelerometer, gyroscope, and camera to extract pulse and respiratory waves of 12 participants during a controlled experiment. We show it is possible to achieve a mean absolute error of 0.82 beats per minute (STD: 1.98 for heart rate and 0.6 breaths per minute (STD: 1.19 for respiration rate when considering different observation windows and combinations of sensors. Moreover, we show that a head-mounted gyroscope sensor shows improved performance versus more commonly explored sensors such as accelerometers and demonstrate that a head-mounted camera is a novel and promising method to capture the physiological responses of the wearer. These findings included testing across sitting, supine, and standing postures before and after physical exercise.

  7. Recording stereoscopic 3D neurosurgery with a head-mounted 3D camera system.

    Science.gov (United States)

    Lee, Brian; Chen, Brian R; Chen, Beverly B; Lu, James Y; Giannotta, Steven L

    2015-06-01

    Stereoscopic three-dimensional (3D) imaging can present more information to the viewer and further enhance the learning experience over traditional two-dimensional (2D) video. Most 3D surgical videos are recorded from the operating microscope and only feature the crux, or the most important part of the surgery, leaving out other crucial parts of surgery including the opening, approach, and closing of the surgical site. In addition, many other surgeries including complex spine, trauma, and intensive care unit procedures are also rarely recorded. We describe and share our experience with a commercially available head-mounted stereoscopic 3D camera system to obtain stereoscopic 3D recordings of these seldom recorded aspects of neurosurgery. The strengths and limitations of using the GoPro(®) 3D system as a head-mounted stereoscopic 3D camera system in the operating room are reviewed in detail. Over the past several years, we have recorded in stereoscopic 3D over 50 cranial and spinal surgeries and created a library for education purposes. We have found the head-mounted stereoscopic 3D camera system to be a valuable asset to supplement 3D footage from a 3D microscope. We expect that these comprehensive 3D surgical videos will become an important facet of resident education and ultimately lead to improved patient care.

  8. A miniature shoe-mounted orientation determination system for accurate indoor heading and trajectory tracking.

    Science.gov (United States)

    Zhang, Shengzhi; Yu, Shuai; Liu, Chaojun; Liu, Sheng

    2016-06-01

    Tracking the position of pedestrian is urgently demanded when the most commonly used GPS (Global Position System) is unavailable. Benefited from the small size, low-power consumption, and relatively high reliability, micro-electro-mechanical system sensors are well suited for GPS-denied indoor pedestrian heading estimation. In this paper, a real-time miniature orientation determination system (MODS) was developed for indoor heading and trajectory tracking based on a novel dual-linear Kalman filter. The proposed filter precludes the impact of geomagnetic distortions on pitch and roll that the heading is subjected to. A robust calibration approach was designed to improve the accuracy of sensors measurements based on a unified sensor model. Online tests were performed on the MODS with an improved turntable. The results demonstrate that the average RMSE (root-mean-square error) of heading estimation is less than 1°. Indoor heading experiments were carried out with the MODS mounted on the shoe of pedestrian. Besides, we integrated the existing MODS into an indoor pedestrian dead reckoning application as an example of its utility in realistic actions. A human attitude-based walking model was developed to calculate the walking distance. Test results indicate that mean percentage error of indoor trajectory tracking achieves 2% of the total walking distance. This paper provides a feasible alternative for accurate indoor heading and trajectory tracking.

  9. Head-mounted LED for optogenetic experiments of freely-behaving animal

    Science.gov (United States)

    Kwon, Ki Yong; Gnade, Andrew G.; Rush, Alexander D.; Patten, Craig D.

    2016-03-01

    Recent developments in optogenetics have demonstrated the ability to target specific types of neurons with sub-millisecond temporal precision via direct optical stimulation of genetically modified neurons in the brain. In most applications, the beam of a laser is coupled to an optical fiber, which guides and delivers the optical power to the region of interest. Light emitting diodes (LEDs) are an alternative light source for optogenetics and they provide many advantages over a laser based system including cost, size, illumination stability, and fast modulation. Their compact size and low power consumption make LEDs suitable light sources for a wireless optogenetic stimulation system. However, the coupling efficiency of an LED's output light into an optical fiber is lower than a laser due to its noncollimated output light. In typical chronic optogenetic experiment, the output of the light source is transmitted to the brain through a patch cable and a fiber stub implant, and this configuration requires two fiber-to-fiber couplings. Attenuation within the patch cable is potential source of optical power loss. In this study, we report and characterize a recently developed light delivery method for freely-behaving animal experiments. We have developed a head-mounted light source that maximizes the coupling efficiency of an LED light source by eliminating the need for a fiber optic cable. This miniaturized LED is designed to couple directly to the fiber stub implant. Depending on the desired optical power output, the head-mounted LED can be controlled by either a tethered (high power) or battery-powered wireless (moderate power) controller. In the tethered system, the LED is controlled through 40 gauge micro coaxial cable which is thinner, more flexible, and more durable than a fiber optic cable. The battery-powered wireless system uses either infrared or radio frequency transmission to achieve real-time control. Optical, electrical, mechanical, and thermal

  10. A Dose of Reality: Overcoming Usability Challenges\\ud in VR Head-Mounted Displays

    OpenAIRE

    McGill, M.; Boland, Daniel; Murray-Smith, Roderick; Brewster, Stephen

    2015-01-01

    We identify usability challenges facing consumers adopting\\ud Virtual Reality (VR) head-mounted displays (HMDs) in a survey\\ud of 108 VR HMD users. Users reported significant issues\\ud in interacting with, and being aware of their real-world\\ud context when using a HMD. Building upon existing work on\\ud blending real and virtual environments, we performed three\\ud design studies to address these usability concerns. In a typing\\ud study, we show that augmenting VR with a view of reality\\ud sig...

  11. Application of head-mounted devices with eye-tracking in virtual reality therapy

    Directory of Open Access Journals (Sweden)

    Lutz Otto Hans-Martin

    2017-03-01

    Full Text Available Using eye-tracking to assess visual attention in head-mounted devices (HMD opens up many possibilities for virtual reality (VR-based therapy. Existing therapy concepts where attention plays a major role can be transferred to VR. Furthermore, they can be expanded to a precise real-time attention assessment, which can serve as a foundation for new therapy approaches. Utilizing HMDs and eye-tracking in a clinical environment is challenging because of hygiene issues and requirements of patients with heterogeneous cognitive and motor impairments. In this paper, we provide an overview of those challenges, discuss possible solutions and present preliminary results of a study with patients.

  12. A novel approach to patient self-monitoring of sonographic examinations using a head-mounted display.

    Science.gov (United States)

    Inoue, Masaharu; Kihara, Kazunori; Yoshida, Soichiro; Ito, Masaya; Takeshita, Hideki; Ishioka, Junichiro; Matsuoka, Yoh; Numao, Noboru; Saito, Kazutaka; Fujii, Yasuhisa

    2015-01-01

    Patients' use of a head-mounted display during their sonographic examinations could provide them with information about their diseases in real time and might help improve "patient-centered care." We conducted this prospective study to evaluate the feasibility of a modern head-mounted display for patient self-monitoring of sonographic examinations. In November and December 2013, 58 patients were enrolled. Patients wore a head-mounted display (HMZ-T2; Sony Corporation, Tokyo, Japan) during their sonographic examinations and watched their own images in real time. After the sonographic examinations, the patients completed a questionnaire, in which they evaluated the utility of the head-mounted display, their understanding of their diseases, their satisfaction with using the head-mounted display, and any adverse events. Until November 26, 2013, patients' names were requested on the questionnaire; after that date, the questionnaire was changed to be anonymous. Of the 58 patients, 56 (97%) elected to participate in this study. The head-mounted display was reported to have good image quality by 42 patients (75%) and good wearability by 39 (70%). Thirty-six patients (64%) reported they had deepened their understanding of their diseases. There were no major complications, and only 2 patients (4%) had mild eye fatigue. There was no significant association between questionnaire results and patient characteristics. None of the questionnaire results changed significantly after the questionnaire was made anonymous. The use of a modern head-mounted display by patients during sonographic examinations provided good image quality with acceptable wearability. It could deepen their understanding of their diseases and help develop patient-centered care. © 2015 by the American Institute of Ultrasound in Medicine.

  13. Immersive virtual walk-through development for tokamak using active head mounted display

    International Nuclear Information System (INIS)

    Dutta, Pramit

    2015-01-01

    A fully immersive virtual walk-through of the SST-1 tokamak has been developed. The virtual walkthrough renders the virtual model of SST-1 tokamak through a active stereoscopic head mounted display to visualize the virtual environment. All locations inside and outside of the reactor can be accessed and reviewed. Such a virtual walkthrough provides a 1:1 scale visualization of all components of the tokamak. To achieve such a virtual model, the graphical details of the tokamak CAD model are enhanced. Such enhancements are provided to improve lighting conditions at various locations, texturing of components to have a realistic visual effect and 360° rendering for ease of access. The graphical enhancements also include the redefinition of the facets to optimize the surface triangles to remove lags in display during visual rendering. Two separate algorithms are developed to interact with the virtual model. A fly-by algorithm, developed using C#, uses inputs from a commercial joystick to navigate within the virtual environment. The second algorithm uses the IR and gyroscopic tracking system of the head mounted display to render view as per the current pose of the user within the virtual environment and the direction of view. Such a virtual walk-thorough can be used extensively for design review and integration, review of new components, operator training for remote handling, operations, upgrades of tokamak, etc. (author)

  14. Hybrid diffractive-refractive optical system design of head-mounted display for augmented reality

    Science.gov (United States)

    Zhang, Huijuan

    2005-02-01

    An optical see-through head-mounted display for augmented reality is designed in this paper. Considering the factors, such as the optical performance, the utilization ratios of energy of real world and virtual world, the feelings of users when he wears it and etc., a structure of the optical see-through is adopted. With the characteristics of the particular negative dispersive and the power of realizing random-phase modulation, the diffractive surface is helpful for optical system of reducing weight, simplifying structure and etc., and a diffractive surface is introduced in our optical system. The optical system with 25 mm eye relief, 12 mm exit pupil and 20° (H)x15.4° (V) field-of-view is designed. The utilization ratios of energy of real world and virtual world are 1/4 and 1/2, respectively. The angular resolution of display is 0.27 mrad and it less than that of the minimum of human eyes. The diameter of this system is less than 46mm, and it applies the binocular. This diffractive-refractive optical system of see-through head-mounted display not only satisfies the demands of user"s factors in structure, but also with high resolution, very small chromatic aberration and distortion, and satisfies the need of augmented reality. In the end, the parameters of the diffractive surface are discussed.

  15. Photosensor-Based Latency Measurement System for Head-Mounted Displays

    Directory of Open Access Journals (Sweden)

    Min-Woo Seo

    2017-05-01

    Full Text Available In this paper, a photosensor-based latency measurement system for head-mounted displays (HMDs is proposed. The motion-to-photon latency is the greatest reason for motion sickness and dizziness felt by users when wearing an HMD system. Therefore, a measurement system is required to accurately measure and analyze the latency to reduce these problems. The existing measurement system does not consider the actual physical movement in humans, and its accuracy is also very low. However, the proposed system considers the physical head movement and is highly accurate. Specifically, it consists of a head position model-based rotary platform, pixel luminance change detector, and signal analysis and calculation modules. Using these modules, the proposed system can exactly measure the latency, which is the time difference between the physical movement for a user and the luminance change of an output image. In the experiment using a commercial HMD, the latency was measured to be up to 47.05 ms. In addition, the measured latency increased up to 381.17 ms when increasing the rendering workload in the HMD.

  16. Optical gesture sensing and depth mapping technologies for head-mounted displays: an overview

    Science.gov (United States)

    Kress, Bernard; Lee, Johnny

    2013-05-01

    Head Mounted Displays (HMDs), and especially see-through HMDs have gained renewed interest in recent time, and for the first time outside the traditional military and defense realm, due to several high profile consumer electronics companies presenting their products to hit market. Consumer electronics HMDs have quite different requirements and constrains as their military counterparts. Voice comments are the de-facto interface for such devices, but when the voice recognition does not work (not connection to the cloud for example), trackpad and gesture sensing technologies have to be used to communicate information to the device. We review in this paper the various technologies developed today integrating optical gesture sensing in a small footprint, as well as the various related 3d depth mapping sensors.

  17. Optical methods for enabling focus cues in head-mounted displays for virtual and augmented reality

    Science.gov (United States)

    Hua, Hong

    2017-05-01

    Developing head-mounted displays (HMD) that offer uncompromised optical pathways to both digital and physical worlds without encumbrance and discomfort confronts many grand challenges, both from technological perspectives and human factors. Among the many challenges, minimizing visual discomfort is one of the key obstacles. One of the key contributing factors to visual discomfort is the lack of the ability to render proper focus cues in HMDs to stimulate natural eye accommodation responses, which leads to the well-known accommodation-convergence cue discrepancy problem. In this paper, I will provide a summary on the various optical methods approaches toward enabling focus cues in HMDs for both virtual reality (VR) and augmented reality (AR).

  18. A clinical technique for virtual articulator mounting with natural head position by using calibrated stereophotogrammetry.

    Science.gov (United States)

    Lam, Walter Y H; Hsung, Richard T C; Choi, Winnie W S; Luk, Henry W K; Cheng, Leo Y Y; Pow, Edmond H N

    2017-09-29

    Accurate articulator-mounted casts are essential for occlusion analysis and for fabrication of dental prostheses. Although the axis orbital plane has been commonly used as the reference horizontal plane, some clinicians prefer to register the horizontal plane with a spirit level when the patient is in the natural head position (NHP) to avoid anatomic landmark variations. This article presents a digital workflow for registering the patient's horizontal plane in NHP on a virtual articulator. An orientation reference board is used to calibrate a stereophotogrammetry device and a 3-dimensional facial photograph with the patient in NHP. The horizontal plane can then be automatically registered to the patient's virtual model and aligned to the virtual articulator at the transverse horizontal axis level. This technique showed good repeatability with positional differences of less than 1 degree and 1 mm in 5 repeated measurements in 1 patient. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Continued Testing of Head-Mounted Displays for Deaf Education in a Planetarium

    Science.gov (United States)

    Hintz, Eric G.; Jones, M.; Lawler, J.; Bench, N.; Mangrubang, F. R.

    2013-06-01

    For more than a year now we have been developing techniques for using Head-Mounted Displays (HMD) to help accommodate a deaf audience in a planetarium environment. Our target audience is primarily children from 8 to 13 years of age, but the methodologies can be used for a wide variety of audiences. Applications also extend beyond the planetarium environment. Three tests have been done to determine if American Sign Language (ASL) can be delivered to the HMD and the student view both the planetarium show and the ASL ‘sound track’. From those early results we are now at the point of testing for comprehension improvement on a number of astronomical subjects. We will present a number of these early results.

  20. A review of the use of virtual reality head-mounted displays in education and training

    DEFF Research Database (Denmark)

    Jensen, Lasse; Konradsen, Flemming

    2017-01-01

    In the light of substantial improvements to the quality and availability of virtual reality (VR) hardware seen since 2013, this review seeks to update our knowledge about the use of head-mounted displays (HMDs) in education and training. Following a comprehensive search 21 documents reporting...... on experimental studies were identified, quality assessed, and analysed. The quality assessment shows that the study quality was below average according to the Medical Education Research Study Quality Instrument, especially for the studies that were designed as user evaluations of educational VR products......; and affective skills related to controlling your emotional response to stressful or difficult situations. Outside of these situations the HMDs had no advantage when compared to less immersive technologies or traditional instruction and in some cases even proved counterproductive because of widespread...

  1. Registration of an on-axis see-through head-mounted display and camera system

    Science.gov (United States)

    Luo, Gang; Rensing, Noa M.; Weststrate, Evan; Peli, Eli

    2005-02-01

    An optical see-through head-mounted display (HMD) system integrating a miniature camera that is aligned with the user's pupil is developed and tested. Such an HMD system has a potential value in many augmented reality applications, in which registration of the virtual display to the real scene is one of the critical aspects. The camera alignment to the user's pupil results in a simple yet accurate calibration and a low registration error across a wide range of depth. In reality, a small camera-eye misalignment may still occur in such a system due to the inevitable variations of HMD wearing position with respect to the eye. The effects of such errors are measured. Calculation further shows that the registration error as a function of viewing distance behaves nearly the same for different virtual image distances, except for a shift. The impact of prismatic effect of the display lens on registration is also discussed.

  2. Brain state-dependence of electrically evoked potentials monitored with head-mounted electronics.

    Science.gov (United States)

    Richardson, Andrew G; Fetz, Eberhard E

    2012-11-01

    Inferring changes in brain connectivity is critical to studies of learning-related plasticity and stimulus-induced conditioning of neural circuits. In addition, monitoring spontaneous fluctuations in connectivity can provide insight into information processing during different brain states. Here, we quantified state-dependent connectivity changes throughout the 24-h sleep-wake cycle in freely behaving monkeys. A novel, head-mounted electronic device was used to electrically stimulate at one site and record evoked potentials at other sites. Electrically evoked potentials (EEPs) revealed the connectivity pattern between several cortical sites and the basal forebrain. We quantified state-dependent changes in the EEPs. Cortico-cortical EEP amplitude increased during slow-wave sleep, compared to wakefulness, while basal-cortical EEP amplitude decreased. The results demonstrate the utility of using portable electronics to document state-dependent connectivity changes in freely behaving primates.

  3. Computer-enhanced stereoscopic vision in a head-mounted operating binocular

    International Nuclear Information System (INIS)

    Birkfellner, Wolfgang; Figl, Michael; Matula, Christian; Hummel, Johann; Hanel, Rudolf; Imhof, Herwig; Wanschitz, Felix; Wagner, Arne; Watzinger, Franz; Bergmann, Helmar

    2003-01-01

    Based on the Varioscope, a commercially available head-mounted operating binocular, we have developed the Varioscope AR, a see through head-mounted display (HMD) for augmented reality visualization that seamlessly fits into the infrastructure of a surgical navigation system. We have assessed the extent to which stereoscopic visualization improves target localization in computer-aided surgery in a phantom study. In order to quantify the depth perception of a user aiming at a given target, we have designed a phantom simulating typical clinical situations in skull base surgery. Sixteen steel spheres were fixed at the base of a bony skull, and several typical craniotomies were applied. After having taken CT scans, the skull was filled with opaque jelly in order to simulate brain tissue. The positions of the spheres were registered using VISIT, a system for computer-aided surgical navigation. Then attempts were made to locate the steel spheres with a bayonet probe through the craniotomies using VISIT and the Varioscope AR as a stereoscopic display device. Localization of targets 4 mm in diameter using stereoscopic vision and additional visual cues indicating target proximity had a success rate (defined as a first-trial hit rate) of 87.5%. Using monoscopic vision and target proximity indication, the success rate was found to be 66.6%. Omission of visual hints on reaching a target yielded a success rate of 79.2% in the stereo case and 56.25% with monoscopic vision. Time requirements for localizing all 16 targets ranged from 7.5 min (stereo, with proximity cues) to 10 min (mono, without proximity cues). Navigation error is primarily governed by the accuracy of registration in the navigation system, whereas the HMD does not appear to influence localization significantly. We conclude that stereo vision is a valuable tool in augmented reality guided interventions. (note)

  4. Head-mounted display for use in functional endoscopic sinus surgery

    Science.gov (United States)

    Wong, Brian J.; Lee, Jon P.; Dugan, F. Markoe; MacArthur, Carol J.

    1995-05-01

    Since the introduction of functional endoscopic sinus surgery (FESS), the procedure has undergone rapid change with evolution keeping pace with technological advances. The advent of low cost charge coupled device 9CCD) cameras revolutionized the practice and instruction of FESS. Video-based FESS has allowed for documentation of the surgical procedure as well as interactive instruction during surgery. Presently, the technical requirements of video-based FESS include the addition of one or more television monitors positioned strategically in the operating room. Thought video monitors have greatly enhanced surgical endoscopy by re- involving nurses and assistants in the actual mechanics of surgery, video monitors require the operating surgeon to be focused on the screen instead of the patient. In this study, we describe the use of a new low-cost liquid crystal display (LCD) based device that functions as a monitor but is mounted on the head on a visor (PT-O1, O1 Products, Westlake Village, CA). This study illustrates the application of these HMD devices to FESS operations. The same surgeon performed the operation in each patient. In one nasal fossa, surgery was performed using conventional video FESS methods. The contralateral side was operated on while wearing the head mounted video display. The device had adequate resolution for the purposes of FESS. No adverse effects were noted intraoperatively. The results on the patients ipsalateral and contralateral sides were similar. The visor did eliminated significant torsion of the surgeon's neck during the operation, while at the same time permitted simultaneous viewing of both the patient and the intranasal surgical field.

  5. A Depth-Based Head-Mounted Visual Display to Aid Navigation in Partially Sighted Individuals

    Science.gov (United States)

    Hicks, Stephen L.; Wilson, Iain; Muhammed, Louwai; Worsfold, John; Downes, Susan M.; Kennard, Christopher

    2013-01-01

    Independent navigation for blind individuals can be extremely difficult due to the inability to recognise and avoid obstacles. Assistive techniques such as white canes, guide dogs, and sensory substitution provide a degree of situational awareness by relying on touch or hearing but as yet there are no techniques that attempt to make use of any residual vision that the individual is likely to retain. Residual vision can restricted to the awareness of the orientation of a light source, and hence any information presented on a wearable display would have to limited and unambiguous. For improved situational awareness, i.e. for the detection of obstacles, displaying the size and position of nearby objects, rather than including finer surface details may be sufficient. To test whether a depth-based display could be used to navigate a small obstacle course, we built a real-time head-mounted display with a depth camera and software to detect the distance to nearby objects. Distance was represented as brightness on a low-resolution display positioned close to the eyes without the benefit focussing optics. A set of sighted participants were monitored as they learned to use this display to navigate the course. All were able to do so, and time and velocity rapidly improved with practise with no increase in the number of collisions. In a second experiment a cohort of severely sight-impaired individuals of varying aetiologies performed a search task using a similar low-resolution head-mounted display. The majority of participants were able to use the display to respond to objects in their central and peripheral fields at a similar rate to sighted controls. We conclude that the skill to use a depth-based display for obstacle avoidance can be rapidly acquired and the simplified nature of the display may appropriate for the development of an aid for sight-impaired individuals. PMID:23844067

  6. Google Glass Glare: disability glare produced by a head-mounted visual display.

    Science.gov (United States)

    Longley, Chris; Whitaker, David

    2016-03-01

    Head mounted displays are a type of wearable technology - a market that is projected to expand rapidly over the coming years. Probably the most well known example is the device Google Glass (or 'Glass'). Here we investigate the extent to which the device display can interfere with normal visual function by producing monocular disability glare. Contrast sensitivity was measured in two normally sighted participants, 32 and 52 years of age. Data were recorded for the right eye, the left eye and then again in a binocular condition. Measurements were taken both with and without the Glass in place, across a range of stimulus luminance levels using a two-alternative forced-choice methodology. The device produced a significant reduction in contrast sensitivity in the right eye (>0.5 log units). The level of disability glare increased as stimulus luminance was reduced in a manner consistent with intraocular light scatter, resulting in a veiling retinal illuminance. Sensitivity in the left eye was unaffected. A significant reduction in binocular contrast sensitivity occurred at lower luminance levels due to a loss of binocular summation, although binocular sensitivity was not found to fall below the sensitivity of the better monocular level (binocular inhibition). Head mounted displays such as Google Glass have the potential to cause significant disability glare in the eye exposed to the visual display, particularly under conditions of low luminance. They can also cause a more modest binocular reduction in sensitivity by eliminating the benefits of binocular summation. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.

  7. Markerless Augmented Reality via Stereo Video See-Through Head-Mounted Display Device

    Directory of Open Access Journals (Sweden)

    Chung-Hung Hsieh

    2015-01-01

    Full Text Available Conventionally, the camera localization for augmented reality (AR relies on detecting a known pattern within the captured images. In this study, a markerless AR scheme has been designed based on a Stereo Video See-Through Head-Mounted Display (HMD device. The proposed markerless AR scheme can be utilized for medical applications such as training, telementoring, or preoperative explanation. Firstly, a virtual model for AR visualization is aligned to the target in physical space by an improved Iterative Closest Point (ICP based surface registration algorithm, with the target surface structure reconstructed by a stereo camera pair; then, a markerless AR camera localization method is designed based on the Kanade-Lucas-Tomasi (KLT feature tracking algorithm and the Random Sample Consensus (RANSAC correction algorithm. Our AR camera localization method is shown to be better than the traditional marker-based and sensor-based AR environment. The demonstration system was evaluated with a plastic dummy head and the display result is satisfactory for a multiple-view observation.

  8. A Statistical Approach to Continuous Self-Calibrating Eye Gaze Tracking for Head-Mounted Virtual Reality Systems

    OpenAIRE

    Tripathi, Subarna; Guenter, Brian

    2016-01-01

    We present a novel, automatic eye gaze tracking scheme inspired by smooth pursuit eye motion while playing mobile games or watching virtual reality contents. Our algorithm continuously calibrates an eye tracking system for a head mounted display. This eliminates the need for an explicit calibration step and automatically compensates for small movements of the headset with respect to the head. The algorithm finds correspondences between corneal motion and screen space motion, and uses these to...

  9. Head-mounted eye tracking of a chimpanzee under naturalistic conditions.

    Directory of Open Access Journals (Sweden)

    Fumihiro Kano

    Full Text Available This study offers a new method for examining the bodily, manual, and eye movements of a chimpanzee at the micro-level. A female chimpanzee wore a lightweight head-mounted eye tracker (60 Hz on her head while engaging in daily interactions with the human experimenter. The eye tracker recorded her eye movements accurately while the chimpanzee freely moved her head, hands, and body. Three video cameras recorded the bodily and manual movements of the chimpanzee from multiple angles. We examined how the chimpanzee viewed the experimenter in this interactive setting and how the eye movements were related to the ongoing interactive contexts and actions. We prepared two experimentally defined contexts in each session: a face-to-face greeting phase upon the appearance of the experimenter in the experimental room, and a subsequent face-to-face task phase that included manual gestures and fruit rewards. Overall, the general viewing pattern of the chimpanzee, measured in terms of duration of individual fixations, length of individual saccades, and total viewing duration of the experimenter's face/body, was very similar to that observed in previous eye-tracking studies that used non-interactive situations, despite the differences in the experimental settings. However, the chimpanzee viewed the experimenter and the scene objects differently depending on the ongoing context and actions. The chimpanzee viewed the experimenter's face and body during the greeting phase, but viewed the experimenter's face and hands as well as the fruit reward during the task phase. These differences can be explained by the differential bodily/manual actions produced by the chimpanzee and the experimenter during each experimental phase (i.e., greeting gestures, task cueing. Additionally, the chimpanzee's viewing pattern varied depending on the identity of the experimenter (i.e., the chimpanzee's prior experience with the experimenter. These methods and results offer new

  10. The Effect of Head Mounted Display Weight and Locomotion Method on the Perceived Naturalness of Virtual Walking Speeds

    DEFF Research Database (Denmark)

    Nilsson, Niels Chr.; Serafin, Stefania; Nordahl, Rolf

    This poster details a study investigating the effect of Head Mounted Display (HMD) weight and locomotion method (Walking-In-Place and treadmill walking) on the perceived naturalness of virtual walking speeds. The results revealed significant main effects of movement type, but no significant effec...

  11. Virtual reality exposure treatment of agoraphobia: a comparison of computer automatic virtual environment and head-mounted display

    NARCIS (Netherlands)

    Meyerbröker, K.; Morina, N.; Kerkhof, G.; Emmelkamp, P.M.G.; Wiederhold, B.K.; Bouchard, S.; Riva, G.

    2011-01-01

    In this study the effects of virtual reality exposure therapy (VRET) were investigated in patients with panic disorder and agoraphobia. The level of presence in VRET was compared between using either a head-mounted display (HMD) or a computer automatic virtual environment (CAVE). Results indicate

  12. Advancement of thyroid surgery video recording: A comparison between two full HD head mounted video cameras.

    Science.gov (United States)

    Ortensi, Andrea; Panunzi, Andrea; Trombetta, Silvia; Cattaneo, Alberto; Sorrenti, Salvatore; D'Orazi, Valerio

    2017-05-01

    The aim of this study was to test two different video cameras and recording systems used in thyroid surgery in our Department. This is meant to be an attempt to record the real point of view of the magnified vision of surgeon, so as to make the viewer aware of the difference with the naked eye vision. In this retrospective study, we recorded and compared twenty thyroidectomies performed using loupes magnification and microsurgical technique: ten were recorded with GoPro ® 4 Session action cam (commercially available) and ten with our new prototype of head mounted video camera. Settings were selected before surgery for both cameras. The recording time is about from 1 to 2 h for GoPro ® and from 3 to 5 h for our prototype. The average time of preparation to fit the camera on the surgeon's head and set the functionality is about 5 min for GoPro ® and 7-8 min for the prototype, mostly due to HDMI wiring cable. Videos recorded with the prototype require no further editing, which is mandatory for videos recorded with GoPro ® to highlight the surgical details. the present study showed that our prototype of video camera, compared with GoPro ® 4 Session, guarantees best results in terms of surgical video recording quality, provides to the viewer the exact perspective of the microsurgeon and shows accurately his magnified view through the loupes in thyroid surgery. These recordings are surgical aids for teaching and education and might be a method of self-analysis of surgical technique. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  13. Recognition of American Sign Language (ASL) Classifiers in a Planetarium Using a Head-Mounted Display

    Science.gov (United States)

    Hintz, Eric G.; Jones, Michael; Lawler, Jeannette; Bench, Nathan

    2015-01-01

    A traditional accommodation for the deaf or hard-of-hearing in a planetarium show is some type of captioning system or a signer on the floor. Both of these have significant drawbacks given the nature of a planetarium show. Young audience members who are deaf likely don't have the reading skills needed to make a captioning system effective. A signer on the floor requires light which can then splash onto the dome. We have examined the potential of using a Head-Mounted Display (HMD) to provide an American Sign Language (ASL) translation. Our preliminary test used a canned planetarium show with a pre-recorded sound track. Since many astronomical objects don't have official ASL signs, the signer had to use classifiers to describe the different objects. Since these are not official signs, these classifiers provided a way to test to see if students were picking up the information using the HMD.We will present results that demonstrate that the use of HMDs is at least as effective as projecting a signer on the dome. This also showed that the HMD could provide the necessary accommodation for students for whom captioning was ineffective. We will also discuss the current effort to provide a live signer without the light splash effect and our early results on teaching effectiveness with HMDs.This work is partially supported by funding from the National Science Foundation grant IIS-1124548 and the Sorenson Foundation.

  14. Automatic cell identification and visualization using digital holographic microscopy with head mounted augmented reality devices.

    Science.gov (United States)

    O'Connor, Timothy; Rawat, Siddharth; Markman, Adam; Javidi, Bahram

    2018-03-01

    We propose a compact imaging system that integrates an augmented reality head mounted device with digital holographic microscopy for automated cell identification and visualization. A shearing interferometer is used to produce holograms of biological cells, which are recorded using customized smart glasses containing an external camera. After image acquisition, segmentation is performed to isolate regions of interest containing biological cells in the field-of-view, followed by digital reconstruction of the cells, which is used to generate a three-dimensional (3D) pseudocolor optical path length profile. Morphological features are extracted from the cell's optical path length map, including mean optical path length, coefficient of variation, optical volume, projected area, projected area to optical volume ratio, cell skewness, and cell kurtosis. Classification is performed using the random forest classifier, support vector machines, and K-nearest neighbor, and the results are compared. Finally, the augmented reality device displays the cell's pseudocolor 3D rendering of its optical path length profile, extracted features, and the identified cell's type or class. The proposed system could allow a healthcare worker to quickly visualize cells using augmented reality smart glasses and extract the relevant information for rapid diagnosis. To the best of our knowledge, this is the first report on the integration of digital holographic microscopy with augmented reality devices for automated cell identification and visualization.

  15. Visuomotor adaptation in head-mounted virtual reality versus conventional training

    Science.gov (United States)

    Anglin, J. M.; Sugiyama, T.; Liew, S.-L.

    2017-01-01

    Immersive, head-mounted virtual reality (HMD-VR) provides a unique opportunity to understand how changes in sensory environments affect motor learning. However, potential differences in mechanisms of motor learning and adaptation in HMD-VR versus a conventional training (CT) environment have not been extensively explored. Here, we investigated whether adaptation on a visuomotor rotation task in HMD-VR yields similar adaptation effects in CT and whether these effects are achieved through similar mechanisms. Specifically, recent work has shown that visuomotor adaptation may occur via both an implicit, error-based internal model and a more cognitive, explicit strategic component. We sought to measure both overall adaptation and balance between implicit and explicit mechanisms in HMD-VR versus CT. Twenty-four healthy individuals were placed in either HMD-VR or CT and trained on an identical visuomotor adaptation task that measured both implicit and explicit components. Our results showed that the overall timecourse of adaption was similar in both HMD-VR and CT. However, HMD-VR participants utilized a greater cognitive strategy than CT, while CT participants engaged in greater implicit learning. These results suggest that while both conditions produce similar results in overall adaptation, the mechanisms by which visuomotor adaption occurs in HMD-VR appear to be more reliant on cognitive strategies. PMID:28374808

  16. Passive method of eliminating accommodation/convergence disparity in stereoscopic head-mounted displays

    Science.gov (United States)

    Eichenlaub, Jesse B.

    2005-03-01

    The difference in accommodation and convergence distance experienced when viewing stereoscopic displays has long been recognized as a source of visual discomfort. It is especially problematic in head mounted virtual reality and enhanced reality displays, where images must often be displayed across a large depth range or superimposed on real objects. DTI has demonstrated a novel method of creating stereoscopic images in which the focus and fixation distances are closely matched for all parts of the scene from close distances to infinity. The method is passive in the sense that it does not rely on eye tracking, moving parts, variable focus optics, vibrating optics, or feedback loops. The method uses a rapidly changing illumination pattern in combination with a high speed microdisplay to create cones of light that converge at different distances to form the voxels of a high resolution space filling image. A bench model display was built and a series of visual tests were performed in order to demonstrate the concept and investigate both its capabilities and limitations. Results proved conclusively that real optical images were being formed and that observers had to change their focus to read text or see objects at different distances

  17. The effect of viewing a virtual environment through a head-mounted display on balance.

    Science.gov (United States)

    Robert, Maxime T; Ballaz, Laurent; Lemay, Martin

    2016-07-01

    In the next few years, several head-mounted displays (HMD) will be publicly released making virtual reality more accessible. HMD are expected to be widely popular at home for gaming but also in clinical settings, notably for training and rehabilitation. HMD can be used in both seated and standing positions; however, presently, the impact of HMD on balance remains largely unknown. It is therefore crucial to examine the impact of viewing a virtual environment through a HMD on standing balance. To compare static and dynamic balance in a virtual environment perceived through a HMD and the physical environment. The visual representation of the virtual environment was based on filmed image of the physical environment and was therefore highly similar. This is an observational study in healthy adults. No significant difference was observed between the two environments for static balance. However, dynamic balance was more perturbed in the virtual environment when compared to that of the physical environment. HMD should be used with caution because of its detrimental impact on dynamic balance. Sensorimotor conflict possibly explains the impact of HMD on balance. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Surgeon point-of-view recording: Using a high-definition head-mounted video camera in the operating room

    Directory of Open Access Journals (Sweden)

    Akshay Gopinathan Nair

    2015-01-01

    Full Text Available Objective: To study the utility of a commercially available small, portable ultra-high definition (HD camera (GoPro Hero 4 for intraoperative recording. Methods: A head mount was used to fix the camera on the operating surgeon′s head. Due care was taken to protect the patient′s identity. The recorded video was subsequently edited and used as a teaching tool. This retrospective, noncomparative study was conducted at three tertiary eye care centers. The surgeries recorded were ptosis correction, ectropion correction, dacryocystorhinostomy, angular dermoid excision, enucleation, blepharoplasty and lid tear repair surgery (one each. The recorded videos were reviewed, edited, and checked for clarity, resolution, and reproducibility. Results: The recorded videos were found to be high quality, which allowed for zooming and visualization of the surgical anatomy clearly. Minimal distortion is a drawback that can be effectively addressed during postproduction. The camera, owing to its lightweight and small size, can be mounted on the surgeon′s head, thus offering a unique surgeon point-of-view. In our experience, the results were of good quality and reproducible. Conclusions: A head-mounted ultra-HD video recording system is a cheap, high quality, and unobtrusive technique to record surgery and can be a useful teaching tool in external facial and ophthalmic plastic surgery.

  19. Surgeon point-of-view recording: Using a high-definition head-mounted video camera in the operating room.

    Science.gov (United States)

    Nair, Akshay Gopinathan; Kamal, Saurabh; Dave, Tarjani Vivek; Mishra, Kapil; Reddy, Harsha S; Della Rocca, David; Della Rocca, Robert C; Andron, Aleza; Jain, Vandana

    2015-10-01

    To study the utility of a commercially available small, portable ultra-high definition (HD) camera (GoPro Hero 4) for intraoperative recording. A head mount was used to fix the camera on the operating surgeon's head. Due care was taken to protect the patient's identity. The recorded video was subsequently edited and used as a teaching tool. This retrospective, noncomparative study was conducted at three tertiary eye care centers. The surgeries recorded were ptosis correction, ectropion correction, dacryocystorhinostomy, angular dermoid excision, enucleation, blepharoplasty and lid tear repair surgery (one each). The recorded videos were reviewed, edited, and checked for clarity, resolution, and reproducibility. The recorded videos were found to be high quality, which allowed for zooming and visualization of the surgical anatomy clearly. Minimal distortion is a drawback that can be effectively addressed during postproduction. The camera, owing to its lightweight and small size, can be mounted on the surgeon's head, thus offering a unique surgeon point-of-view. In our experience, the results were of good quality and reproducible. A head-mounted ultra-HD video recording system is a cheap, high quality, and unobtrusive technique to record surgery and can be a useful teaching tool in external facial and ophthalmic plastic surgery.

  20. Cybersickness provoked by head-mounted display affects cutaneous vascular tone, heart rate and reaction time.

    Science.gov (United States)

    Nalivaiko, Eugene; Davis, Simon L; Blackmore, Karen L; Vakulin, Andrew; Nesbitt, Keith V

    2015-11-01

    Evidence from studies of provocative motion indicates that motion sickness is tightly linked to the disturbances of thermoregulation. The major aim of the current study was to determine whether provocative visual stimuli (immersion into the virtual reality simulating rides on a rollercoaster) affect skin temperature that reflects thermoregulatory cutaneous responses, and to test whether such stimuli alter cognitive functions. In 26 healthy young volunteers wearing head-mounted display (Oculus Rift), simulated rides consistently provoked vection and nausea, with a significant difference between the two versions of simulation software (Parrot Coaster and Helix). Basal finger temperature had bimodal distribution, with low-temperature group (n=8) having values of 23-29 °C, and high-temperature group (n=18) having values of 32-36 °C. Effects of cybersickness on finger temperature depended on the basal level of this variable: in subjects from former group it raised by 3-4 °C, while in most subjects from the latter group it either did not change or transiently reduced by 1.5-2 °C. There was no correlation between the magnitude of changes in the finger temperature and nausea score at the end of simulated ride. Provocative visual stimulation caused prolongation of simple reaction time by 20-50 ms; this increase closely correlated with the subjective rating of nausea. Lastly, in subjects who experienced pronounced nausea, heart rate was elevated. We conclude that cybersickness is associated with changes in cutaneous thermoregulatory vascular tone; this further supports the idea of a tight link between motion sickness and thermoregulation. Cybersickness-induced prolongation of reaction time raises obvious concerns regarding the safety of this technology. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Optical see-through head-mounted display with occlusion capability

    Science.gov (United States)

    Gao, Chunyu; Lin, Yuxiang; Hua, Hong

    2013-05-01

    Lack of mutual occlusion capability between computer-rendered and real objects is one of fundamental problems for most existing optical see-through head-mounted displays (OST-HMD). Without the proper occlusion management, the virtual view through an OST-HMD appears "ghost-like", floating in the real world. To address this challenge, we have developed an innovative optical scheme that uniquely combines the eyepiece and see-through relay optics to achieve an occlusion-capable OST-HMD system with a very compelling form factor and high optical performances. The proposed display system was based on emerging freeform optical design technologies and was designed for highly efficient liquid crystal on silicon (LCoS) type spatial light modulator (SLM) and bright Organic LED (OLED) microdisplay. The proposed display technology was capable of working in both indoor and outdoor environments. Our current design offered a 1280x1024 color resolution based on 0.8" microdisplay and SLM. The MTF values for the majority of the fields at the cutoff frequency of 40lps/mm, which is determined by the pixel size of the microdisplay, are better than 15%. The design achieved a diagonal FOV of 40 degrees, 31.7 degrees horizontally and 25.6 degrees vertically, an exit pupil diameter of 8mm (non-vignetted), and an eye clearance of 18mm. The optics weights about 20 grams per eye. Our proposed occlusion capable OST-HMD system can easily find myriads of applications in various military and commercial sectors such as military training, gaming and entertainment.

  2. A low-cost multimodal head-mounted display system for neuroendoscopic surgery.

    Science.gov (United States)

    Xu, Xinghua; Zheng, Yi; Yao, Shujing; Sun, Guochen; Xu, Bainan; Chen, Xiaolei

    2018-01-01

    With rapid advances in technology, wearable devices as head-mounted display (HMD) have been adopted for various uses in medical science, ranging from simply aiding in fitness to assisting surgery. We aimed to investigate the feasibility and practicability of a low-cost multimodal HMD system in neuroendoscopic surgery. A multimodal HMD system, mainly consisted of a HMD with two built-in displays, an action camera, and a laptop computer displaying reconstructed medical images, was developed to assist neuroendoscopic surgery. With this intensively integrated system, the neurosurgeon could freely switch between endoscopic image, three-dimensional (3D) reconstructed virtual endoscopy images, and surrounding environment images. Using a leap motion controller, the neurosurgeon could adjust or rotate the 3D virtual endoscopic images at a distance to better understand the positional relation between lesions and normal tissues at will. A total of 21 consecutive patients with ventricular system diseases underwent neuroendoscopic surgery with the aid of this system. All operations were accomplished successfully, and no system-related complications occurred. The HMD was comfortable to wear and easy to operate. Screen resolution of the HMD was high enough for the neurosurgeon to operate carefully. With the system, the neurosurgeon might get a better comprehension on lesions by freely switching among images of different modalities. The system had a steep learning curve, which meant a quick increment of skill with it. Compared with commercially available surgical assistant instruments, this system was relatively low-cost. The multimodal HMD system is feasible, practical, helpful, and relatively cost efficient in neuroendoscopic surgery.

  3. Amblyopia treatment of adults with dichoptic training using the virtual reality oculus rift head mounted display: preliminary results

    OpenAIRE

    Žiak, Peter; Holm, Anders; Halička, Juraj; Mojzis, Peter; Piñero, David P.

    2017-01-01

    Background The gold standard treatments in amblyopia are penalizing therapies, such as patching or blurring vision with atropine that are aimed at forcing the use of the amblyopic eye. However, in the last years, new therapies are being developed and validated, such as dichoptic visual training, aimed at stimulating the amblyopic eye and eliminating the interocular supression. Purpose To evaluate the effect of dichoptic visual training using a virtual reality head mounted display in a sample ...

  4. Effects of Videogame Distraction using a Virtual Reality Type Head-Mounted Display Helmet on Cold Pressor Pain in Children

    OpenAIRE

    Dahlquist, Lynnda M.; Weiss, Karen E.; Dillinger Clendaniel, Lindsay; Law, Emily F.; Ackerman, Claire Sonntag; McKenna, Kristine D.

    2008-01-01

    Objective To test whether a head-mounted display helmet enhances the effectiveness of videogame distraction for children experiencing cold pressor pain. Method Forty-one children, aged 6–14 years, underwent one or two baseline cold pressor trials followed by two distraction trials in which they played the same videogame with and without the helmet in counterbalanced order. Pain threshold (elapsed time until the child reported pain) and pain tolerance (total time the child kept the hand submer...

  5. Visual Search and Target Cueing: A Comparison of Head-Mounted Versus Hand-Held Displays on the Allocation of Visual Attention

    National Research Council Canada - National Science Library

    Yeh, Michelle; Wickens, Christopher D

    1998-01-01

    We conducted a study to examine the effects of target cueing and conformality with a hand-held or head-mounted display to determine their effects on visual search tasks requiring focused and divided attention...

  6. Helmet-mounted display requirements: just another head-up display (HUD) or a different animal altogether?

    Science.gov (United States)

    Newman, Richard L.; Haworth, Loran A.

    1994-06-01

    The helmet-mounted display (HMD) presents flight, navigation, and weapon information in the pilot's line of sight. The HMD was developed to allow the pilot to retain aircraft and weapon information while looking off boresight. The present study reviewed the state-of-the-art in HMDs and identified a number of issues applying to HMDs. Several are identical to head-up display (HUD) issues: symbol standardization, excessive clutter, and the need for integration with other cockpit displays and controls. Other issues are unique to the head-mounted display: symbol stabilization, inadequate definitions, undefined symbol drive laws, helmet considerations, and field-of-view (FOV) vs. resolution tradeoff requirements. Symbol stabilization is critical. In the Apache helicopter, the lack of compensation for pilot head motion creates excessive workload during hovering and nap-of-the-earth (NOE) flight. This high workload translates into excessive training requirements. At the same time, misleading symbology makes interpretation of the height of obstructions impossible. The underlying cause is the absence of design criteria for HMDs. The existing military standard does not reflect the current state of technology. In addition, there are inadequate test and evaluation guidelines. The situation parallels the situation for HUDs several years ago.

  7. Amblyopia treatment of adults with dichoptic training using the virtual reality oculus rift head mounted display: preliminary results.

    Science.gov (United States)

    Žiak, Peter; Holm, Anders; Halička, Juraj; Mojžiš, Peter; Piñero, David P

    2017-06-28

    The gold standard treatments in amblyopia are penalizing therapies, such as patching or blurring vision with atropine that are aimed at forcing the use of the amblyopic eye. However, in the last years, new therapies are being developed and validated, such as dichoptic visual training, aimed at stimulating the amblyopic eye and eliminating the interocular supression. To evaluate the effect of dichoptic visual training using a virtual reality head mounted display in a sample of anisometropic amblyopic adults and to evaluate the potential usefulness of this option of treatment. A total of 17 subjects (10 men, 7 women) with a mean age of 31.2 years (range, 17-69 year) and anisometropic amblyopia were enrolled. Best corrected visual acuity (BCVA) and stereoacuity (Stereo Randot graded circle test) changes were evaluated after 8 sessions (40 min per session) of dichoptic training with the computer game Diplopia Game (Vivid Vision) run in the Oculus Rift OC DK2 virtual reality head mounted display (Oculus VR). Mean BCVA in amblyopic eye improved significantly from a logMAR value of 0.58 ± 0.35 before training to a post-training value of 0.43 ± 0.38 (p virtual reality head mounted display seems to be an effective option of treatment in adults with anisometropic amblyopia. Future clinical trials are needed to confirm this preliminary evidence. Trial ID: ISRCTN62086471 . Date registered: 13/06/2017. Retrospectively registered.

  8. Multiple-Objective Particle Swarm Optimization for Multi-Head Beam-Type Surface Mounting Machines

    NARCIS (Netherlands)

    Torabi, S.A.; Hamedi, M.; Ashayeri, J.

    2010-01-01

    The growing demand for electronic devices has made the manufacturing of printed circuit boards (PCBs) a promising industry over the last decades. As the demand for printed circuit boards increases, the industry becomes more dependent on highly automated assembly processes using Surface Mounting

  9. COMPARISON OF A HEAD MOUNTED IMPACT MEASUREMENT DEVICE TO THE HYBRID III ANTHROPOMORPHIC TESTING DEVICE IN A CONTROLLED LABORATORY SETTING.

    Science.gov (United States)

    Schussler, Eric; Stark, David; Bolte, John H; Kang, Yun Seok; Onate, James A

    2017-08-01

    Reports estimate that 1.6 to 3.8 million cases of concussion occur in sports and recreation each year in the United States. Despite continued efforts to reduce the occurrence of concussion, the rate of diagnosis continues to increase. The mechanisms of concussion are thought to involve linear and rotational head accelerations and velocities. One method of quantifying the kinematics experienced during sport participation is to place measurement devices into the athlete's helmet or directly on the athlete's head. The purpose of this research to determine the accuracy of a head mounted device for measuring the head accelerations experienced by the wearer. This will be accomplished by identifying the error in Peak Linear Acceleration (PLA), Peak Rotational Acceleration (PRA) and Peak Rotational Velocity (PRV) of the device. Laboratory study. A helmeted Hybrid III 50th percentile male headform was impacted via a pneumatic ram from the front, side, rear, front oblique and rear oblique at speeds from 1.5 to 5 m/s. The X2 Biosystems xPatch® (Seattle, WA) sensor was placed on the headform's right side at the approximate location of the mastoid process. Measures of PLA, PRA, PRV from the xPatch ® and Hybrid III were analyzed for Root Mean Square Error (RMSE), and Absolute and Relative Error (AE, RE). Seventy-six impacts were analyzed. All measures of correlation, fixed through the origin, were found to be strong: PLA R 2 =0.967 pstandard yet above the average error of testing devices in both PLA and PRA, but a low error in PRV. PLA measures from the xPatch® system demonstrated a high level of correlation with the PLA data from the Hybrid III mounted data collection system. 3.

  10. Mounted Combat System Crew Shock Loading: Head and Neck Injury Potential Evaluation

    National Research Council Canada - National Science Library

    LaFiandra, Michael E; Zywiol, Harry

    2007-01-01

    ...) ride motion simulator (RMS) was used to simulate the effects of gun firing shock on a Hybrid III instrumented anthropometric test device capable of measuring neck force and torque and head acceleration...

  11. Thermometric- and Acoustic-Based Beam Power Monitor for Ultra-Bright X-Rays

    International Nuclear Information System (INIS)

    2010-01-01

    A design for an average beam power monitor for ultra-bright X-ray sources is proposed that makes simultaneous use of calorimetry and radiation acoustics. Radiation incident on a solid target will induce heating and ultrasonic vibrations, both of which may be measured to give a fairly precise value of the beam power. The monitor is intended for measuring ultra-bright Free-Electron Laser (FEL) X-ray beams, for which traditional monitoring technologies such as photo-diodes or scintillators are unsuitable. The monitor consists of a Boron Carbide (B 4 C) target designed to absorb most of the incident beam's energy. Resistance temperature detectors (RTD) and piezoelectric actuators are mounted on the outward faces of the target to measure the temperature changes and ultrasonic vibrations induced by the incident beam. The design was tested using an optical pulsed beam (780 nm, 120 and 360 Hz) from a Ti:sapphire oscillator at several energies between 0.8 and 2.6 mJ. The RTDs measured an increase in temperature of about 10 K over a period of several minutes. The piezoelectric sensors recorded ringing acoustic oscillations at 580 ± 40 kHz. Most importantly, the amplitude of the acoustic signals was observed to scale linearly with beam power up to 2 mJ of pulse energy. Above this pulse energy, the vibrational signals became nonlinear. Several causes for this nonlinearity are discussed, including amplifier saturation and piezoelectric saturation. Despite this nonlinearity, these measurements demonstrate the feasibility of such a beam power measurement device. The advantage of two distinct measurements (acoustic and thermometric) provides a useful method of calibration that is unavailable to current LCLS diagnostics tools.

  12. Development of a surgical navigation system based on augmented reality using an optical see-through head-mounted display.

    Science.gov (United States)

    Chen, Xiaojun; Xu, Lu; Wang, Yiping; Wang, Huixiang; Wang, Fang; Zeng, Xiangsen; Wang, Qiugen; Egger, Jan

    2015-06-01

    The surgical navigation system has experienced tremendous development over the past decades for minimizing the risks and improving the precision of the surgery. Nowadays, Augmented Reality (AR)-based surgical navigation is a promising technology for clinical applications. In the AR system, virtual and actual reality are mixed, offering real-time, high-quality visualization of an extensive variety of information to the users (Moussa et al., 2012) [1]. For example, virtual anatomical structures such as soft tissues, blood vessels and nerves can be integrated with the real-world scenario in real time. In this study, an AR-based surgical navigation system (AR-SNS) is developed using an optical see-through HMD (head-mounted display), aiming at improving the safety and reliability of the surgery. With the use of this system, including the calibration of instruments, registration, and the calibration of HMD, the 3D virtual critical anatomical structures in the head-mounted display are aligned with the actual structures of patient in real-world scenario during the intra-operative motion tracking process. The accuracy verification experiment demonstrated that the mean distance and angular errors were respectively 0.809±0.05mm and 1.038°±0.05°, which was sufficient to meet the clinical requirements. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. A new head-mounted display-based augmented reality system in neurosurgical oncology: a study on phantom.

    Science.gov (United States)

    Cutolo, Fabrizio; Meola, Antonio; Carbone, Marina; Sinceri, Sara; Cagnazzo, Federico; Denaro, Ennio; Esposito, Nicola; Ferrari, Mauro; Ferrari, Vincenzo

    2017-12-01

    Benefits of minimally invasive neurosurgery mandate the development of ergonomic paradigms for neuronavigation. Augmented Reality (AR) systems can overcome the shortcomings of commercial neuronavigators. The aim of this work is to apply a novel AR system, based on a head-mounted stereoscopic video see-through display, as an aid in complex neurological lesion targeting. Effectiveness was investigated on a newly designed patient-specific head mannequin featuring an anatomically realistic brain phantom with embedded synthetically created tumors and eloquent areas. A two-phase evaluation process was adopted in a simulated small tumor resection adjacent to Broca's area. Phase I involved nine subjects without neurosurgical training in performing spatial judgment tasks. In Phase II, three surgeons were involved in assessing the effectiveness of the AR-neuronavigator in performing brain tumor targeting on a patient-specific head phantom. Phase I revealed the ability of the AR scene to evoke depth perception under different visualization modalities. Phase II confirmed the potentialities of the AR-neuronavigator in aiding the determination of the optimal surgical access to the surgical target. The AR-neuronavigator is intuitive, easy-to-use, and provides three-dimensional augmented information in a perceptually-correct way. The system proved to be effective in guiding skin incision, craniotomy, and lesion targeting. The preliminary results encourage a structured study to prove clinical effectiveness. Moreover, our testing platform might be used to facilitate training in brain tumour resection procedures.

  14. Binocular vision in a virtual world: visual deficits following the wearing of a head-mounted display.

    Science.gov (United States)

    Mon-Williams, M; Wann, J P; Rushton, S

    1993-10-01

    The short-term effects on binocular stability of wearing a conventional head-mounted display (HMD) to explore a virtual reality environment were examined. Twenty adult subjects (aged 19-29 years) wore a commercially available HMD for 10 min while cycling around a computer generated 3-D world. The twin screen presentations were set to suit the average interpupillary distance of our subject population, to mimic the conditions of public access virtual reality systems. Subjects were examined before and after exposure to the HMD and there were clear signs of induced binocular stress for a number of the subjects. The implications of introducing such HMDs into the workplace and entertainment environments are discussed.

  15. Effects of videogame distraction using a virtual reality type head-mounted display helmet on cold pressor pain in children.

    Science.gov (United States)

    Dahlquist, Lynnda M; Weiss, Karen E; Clendaniel, Lindsay Dillinger; Law, Emily F; Ackerman, Claire Sonntag; McKenna, Kristine D

    2009-06-01

    To test whether a head-mounted display helmet enhances the effectiveness of videogame distraction for children experiencing cold pressor pain. Forty-one children, aged 6-14 years, underwent one or two baseline cold pressor trials followed by two distraction trials in which they played the same videogame with and without the helmet in counterbalanced order. Pain threshold (elapsed time until the child reported pain) and pain tolerance (total time the child kept the hand submerged in the cold water) were measured for each cold pressor trial. Both distraction conditions resulted in improved pain tolerance relative to baseline. Older children appeared to experience additional benefits from using the helmet, whereas younger children benefited equally from both conditions. The findings suggest that virtual reality technology can enhance the effects of distraction for some children. Research is needed to identify the characteristics of children for whom this technology is best suited.

  16. Effects of Videogame Distraction using a Virtual Reality Type Head-Mounted Display Helmet on Cold Pressor Pain in Children

    Science.gov (United States)

    Weiss, Karen E.; Dillinger Clendaniel, Lindsay; Law, Emily F.; Ackerman, Claire Sonntag; McKenna, Kristine D.

    2009-01-01

    Objective To test whether a head-mounted display helmet enhances the effectiveness of videogame distraction for children experiencing cold pressor pain. Method Forty-one children, aged 6–14 years, underwent one or two baseline cold pressor trials followed by two distraction trials in which they played the same videogame with and without the helmet in counterbalanced order. Pain threshold (elapsed time until the child reported pain) and pain tolerance (total time the child kept the hand submerged in the cold water) were measured for each cold pressor trial. Results Both distraction conditions resulted in improved pain tolerance relative to baseline. Older children appeared to experience additional benefits from using the helmet, whereas younger children benefited equally from both conditions. The findings suggest that virtual reality technology can enhance the effects of distraction for some children. Research is needed to identify the characteristics of children for whom this technology is best suited. PMID:18367495

  17. Talk to the virtual hands: self-animated avatars improve communication in head-mounted display virtual environments.

    Directory of Open Access Journals (Sweden)

    Trevor J Dodds

    Full Text Available BACKGROUND: When we talk to one another face-to-face, body gestures accompany our speech. Motion tracking technology enables us to include body gestures in avatar-mediated communication, by mapping one's movements onto one's own 3D avatar in real time, so the avatar is self-animated. We conducted two experiments to investigate (a whether head-mounted display virtual reality is useful for researching the influence of body gestures in communication; and (b whether body gestures are used to help in communicating the meaning of a word. Participants worked in pairs and played a communication game, where one person had to describe the meanings of words to the other. PRINCIPAL FINDINGS: In experiment 1, participants used significantly more hand gestures and successfully described significantly more words when nonverbal communication was available to both participants (i.e. both describing and guessing avatars were self-animated, compared with both avatars in a static neutral pose. Participants 'passed' (gave up describing significantly more words when they were talking to a static avatar (no nonverbal feedback available. In experiment 2, participants' performance was significantly worse when they were talking to an avatar with a prerecorded listening animation, compared with an avatar animated by their partners' real movements. In both experiments participants used significantly more hand gestures when they played the game in the real world. CONCLUSIONS: Taken together, the studies show how (a virtual reality can be used to systematically study the influence of body gestures; (b it is important that nonverbal communication is bidirectional (real nonverbal feedback in addition to nonverbal communication from the describing participant; and (c there are differences in the amount of body gestures that participants use with and without the head-mounted display, and we discuss possible explanations for this and ideas for future investigation.

  18. Usability Comparisons of Head-Mounted vs. Stereoscopic Desktop Displays in a Virtual Reality Environment with Pain Patients.

    Science.gov (United States)

    Tong, Xin; Gromala, Diane; Gupta, Dimple; Squire, Pam

    2016-01-01

    Researchers have shown that immersive Virtual Reality (VR) can serve as an unusually powerful pain control technique. However, research assessing the reported symptoms and negative effects of VR systems indicate that it is important to ascertain if these symptoms arise from the use of particular VR display devices, particularly for users who are deemed "at risk," such as chronic pain patients Moreover, these patients have specific and often complex needs and requirements, and because basic issues such as 'comfort' may trigger anxiety or panic attacks, it is important to examine basic questions of the feasibility of using VR displays. Therefore, this repeated-measured experiment was conducted with two VR displays: the Oculus Rift's head-mounted display (HMD) and Firsthand Technologies' immersive desktop display, DeepStream3D. The characteristics of these immersive desktop displays differ: one is worn, enabling patients to move their heads, while the other is peered into, allowing less head movement. To assess the severity of physical discomforts, 20 chronic pain patients tried both displays while watching a VR pain management demo in clinical settings. Results indicated that participants experienced higher levels of Simulator Sickness using the Oculus Rift HMD. However, results also indicated other preferences of the two VR displays among patients, including physical comfort levels and a sense of immersion. Few studies have been conducted that compare usability of specific VR devices specifically with chronic pain patients using a therapeutic virtual environment in pain clinics. Thus, the results may help clinicians and researchers to choose the most appropriate VR displays for chronic pain patients and guide VR designers to enhance the usability of VR displays for long-term pain management interventions.

  19. An externally head-mounted wireless neural recording device for laboratory animal research and possible human clinical use.

    Science.gov (United States)

    Yin, Ming; Li, Hao; Bull, Christopher; Borton, David A; Aceros, Juan; Larson, Lawrence; Nurmikko, Arto V

    2013-01-01

    In this paper we present a new type of head-mounted wireless neural recording device in a highly compact package, dedicated for untethered laboratory animal research and designed for future mobile human clinical use. The device, which takes its input from an array of intracortical microelectrode arrays (MEA) has ninety-seven broadband parallel neural recording channels and was integrated on to two custom designed printed circuit boards. These house several low power, custom integrated circuits, including a preamplifier ASIC, a controller ASIC, plus two SAR ADCs, a 3-axis accelerometer, a 48MHz clock source, and a Manchester encoder. Another ultralow power RF chip supports an OOK transmitter with the center frequency tunable from 3GHz to 4GHz, mounted on a separate low loss dielectric board together with a 3V LDO, with output fed to a UWB chip antenna. The IC boards were interconnected and packaged in a polyether ether ketone (PEEK) enclosure which is compatible with both animal and human use (e.g. sterilizable). The entire system consumes 17mA from a 1.2Ahr 3.6V Li-SOCl2 1/2AA battery, which operates the device for more than 2 days. The overall system includes a custom RF receiver electronics which are designed to directly interface with any number of commercial (or custom) neural signal processors for multi-channel broadband neural recording. Bench-top measurements and in vivo testing of the device in rhesus macaques are presented to demonstrate the performance of the wireless neural interface.

  20. SU-F-T-310: Does a Head-Mounted Ionization Chamber Detect IMRT Errors?

    International Nuclear Information System (INIS)

    Wegener, S; Herzog, B; Sauer, O

    2016-01-01

    Purpose: The conventional plan verification strategy is delivering a plan to a QA-phantom before the first treatment. Monitoring each fraction of the patient treatment in real-time would improve patient safety. We evaluated how well a new detector, the IQM (iRT Systems, Germany), is capable of detecting errors we induced into IMRT plans of three different treatment regions. Results were compared to an established phantom. Methods: Clinical plans of a brain, prostate and head-and-neck patient were modified in the Pinnacle planning system, such that they resulted in either several percent lower prescribed doses to the target volume or several percent higher doses to relevant organs at risk. Unaltered plans were measured on three days, modified plans once, each with the IQM at an Elekta Synergy with an Agility MLC. All plans were also measured with the ArcCHECK with the cavity plug and a PTW semiflex 31010 ionization chamber inserted. Measurements were evaluated with SNC patient software. Results: Repeated IQM measurements of the original plans were reproducible, such that a 1% deviation from the mean as warning and 3% as action level as suggested by the manufacturer seemed reasonable. The IQM detected most of the simulated errors including wrong energy, a faulty leaf, wrong trial exported and a 2 mm shift of one leaf bank. Detection limits were reached for two plans - a 2 mm field position error and a leaf bank offset combined with an MU change. ArcCHECK evaluation according to our current standards also left undetected errors. Ionization chamber evaluation alone would leave most errors undetected. Conclusion: The IQM detected most errors and performed as well as currently established phantoms with the advantage that it can be used throughout the whole treatment. Drawback is that it does not indicate the source of the error.

  1. SU-F-T-310: Does a Head-Mounted Ionization Chamber Detect IMRT Errors?

    Energy Technology Data Exchange (ETDEWEB)

    Wegener, S; Herzog, B; Sauer, O [University of Wuerzburg, Wuerzburg (Germany)

    2016-06-15

    Purpose: The conventional plan verification strategy is delivering a plan to a QA-phantom before the first treatment. Monitoring each fraction of the patient treatment in real-time would improve patient safety. We evaluated how well a new detector, the IQM (iRT Systems, Germany), is capable of detecting errors we induced into IMRT plans of three different treatment regions. Results were compared to an established phantom. Methods: Clinical plans of a brain, prostate and head-and-neck patient were modified in the Pinnacle planning system, such that they resulted in either several percent lower prescribed doses to the target volume or several percent higher doses to relevant organs at risk. Unaltered plans were measured on three days, modified plans once, each with the IQM at an Elekta Synergy with an Agility MLC. All plans were also measured with the ArcCHECK with the cavity plug and a PTW semiflex 31010 ionization chamber inserted. Measurements were evaluated with SNC patient software. Results: Repeated IQM measurements of the original plans were reproducible, such that a 1% deviation from the mean as warning and 3% as action level as suggested by the manufacturer seemed reasonable. The IQM detected most of the simulated errors including wrong energy, a faulty leaf, wrong trial exported and a 2 mm shift of one leaf bank. Detection limits were reached for two plans - a 2 mm field position error and a leaf bank offset combined with an MU change. ArcCHECK evaluation according to our current standards also left undetected errors. Ionization chamber evaluation alone would leave most errors undetected. Conclusion: The IQM detected most errors and performed as well as currently established phantoms with the advantage that it can be used throughout the whole treatment. Drawback is that it does not indicate the source of the error.

  2. Collision judgment when using an augmented-vision head-mounted display device.

    Science.gov (United States)

    Luo, Gang; Woods, Russell L; Peli, Eli

    2009-09-01

    A device was developed to provide an expanded visual field to patients with tunnel vision by superimposing minified edge images of the wide scene, in which objects appear closer to the heading direction than they really are. Experiments were conducted in a virtual environment to determine whether users would overestimate collision risks. Given simulated scenes of walking or standing with intention to walk toward a given direction (intended walking) in a shopping mall corridor, participants (12 normally sighted and 7 with tunnel vision) reported whether they would collide with obstacles appearing at different offsets from variable walking paths (or intended directions), with and without the device. The collision envelope (CE), a personal space based on perceived collision judgments, and judgment uncertainty (variability of response) were measured. When the device was used, combinations of two image scales (5x minified and 1:1) and two image types (grayscale or edge images) were tested. Image type did not significantly alter collision judgment (P > 0.7). Compared to the without-device baseline, minification did not significantly change the CE of normally sighted subjects for simulated walking (P = 0.12), but increased CE by 30% for intended walking (P 0.25). For the patients, neither CE nor uncertainty was affected by minification (P > 0.13) in both walking conditions. Baseline CE and uncertainty were greater for patients than normally sighted subjects in simulated walking (P = 0.03), but the two groups were not significantly different in all other conditions. Users did not substantially overestimate collision risk, as the x5 minified images had only limited impact on collision judgments either during walking or before starting to walk.

  3. Assessing balance through the use of a low-cost head-mounted display in older adults: a pilot study.

    Science.gov (United States)

    Saldana, Santiago J; Marsh, Anthony P; Rejeski, W Jack; Haberl, Jack K; Wu, Peggy; Rosenthal, Scott; Ip, Edward H

    2017-01-01

    As the population ages, the prevention of falls is an increasingly important public health problem. Balance assessment forms an important component of fall-prevention programs for older adults. The recent development of cost-effective and highly responsive virtual reality (VR) systems means new methods of balance assessment are feasible in a clinical setting. This proof-of-concept study made use of the submillimeter tracking built into modern VR head-mounted displays (VRHMDs) to assess balance through the use of visual-vestibular conflict. The objective of this study was to evaluate the validity, acceptability, and reliability of using a VRHMD to assess balance in older adults. Validity was assessed by comparing measurements from the VRHMD to measurements of postural sway from a force plate. Acceptability was assessed through the use of the Simulator Sickness Questionnaire pre- and postexposure to assess possible side effects of the visual-vestibular conflict. Reliability was assessed by measuring correlations between repeated measurements 1 week apart. Variables of possible importance that were found to be reliable ( r ≥0.9) between tests separated by a week were then tested for differences compared to a control group. Assessment was performed as a cross-sectional single-site community center-based study in 13 older adults (≥65 years old, 80.2±7.3 years old, 77% female, five at risk of falls, eight controls). The VR balance assessment consisted of four modules: a baseline module, a reaction module, a balance module, and a seated assessment. There was a significant difference in the rate at which participants with a risk of falls changed their tilt in the anteroposterior direction compared to the control group. Participants with a risk of falls changed their tilt in the anteroposterior direction at 0.7°/second vs 0.4°/second for those without a history of falls. No significant differences were found between pre/postassessment for oculomotor score or total

  4. A head-mounted display-based personal integrated-image monitoring system for transurethral resection of the prostate.

    Science.gov (United States)

    Yoshida, Soichiro; Kihara, Kazunori; Takeshita, Hideki; Fujii, Yasuhisa

    2014-12-01

    The head-mounted display (HMD) is a new image monitoring system. We developed the Personal Integrated-image Monitoring System (PIM System) using the HMD (HMZ-T2, Sony Corporation, Tokyo, Japan) in combination with video splitters and multiplexers as a surgical guide system for transurethral resection of the prostate (TURP). The imaging information obtained from the cystoscope, the transurethral ultrasonography (TRUS), the video camera attached to the HMD, and the patient's vital signs monitor were split and integrated by the PIM System and a composite image was displayed by the HMD using a four-split screen technique. Wearing the HMD, the lead surgeon and the assistant could simultaneously and continuously monitor the same information displayed by the HMD in an ergonomically efficient posture. Each participant could independently rearrange the images comprising the composite image depending on the engaging step. Two benign prostatic hyperplasia (BPH) patients underwent TURP performed by surgeons guided with this system. In both cases, the TURP procedure was successfully performed, and their postoperative clinical courses had no remarkable unfavorable events. During the procedure, none of the participants experienced any HMD-wear related adverse effects or reported any discomfort.

  5. Chronic monitoring of cortical hemodynamics in behaving, freely-moving rats using a miniaturized head-mounted optical microscope

    Science.gov (United States)

    Sigal, Iliya; Gad, Raanan; Koletar, Margaret; Ringuette, Dene; Stefanovic, Bojana; Levi, Ofer

    2016-03-01

    Growing interest within the neurophysiology community in assessing healthy and pathological brain activity in animals that are awake and freely-behaving has triggered the need for optical systems that are suitable for such longitudinal studies. In this work we report label-free multi-modal imaging of cortical hemodynamics in the somatosensory cortex of awake, freely-behaving rats, using a novel head-mounted miniature optical microscope. The microscope employs vertical cavity surface emitting lasers (VCSELs) at three distinct wavelengths (680 nm, 795 nm, and 850 nm) to provide measurements of four hemodynamic markers: blood flow speeds, HbO, HbR, and total Hb concentration, across a > 2 mm field of view. Blood flow speeds are extracted using Laser Speckle Contrast Imaging (LSCI), while oxygenation measurements are performed using Intrinsic Optical Signal Imaging (IOSI). Longitudinal measurements on the same animal are made possible over the course of > 6 weeks using a chronic window that is surgically implanted into the skull. We use the device to examine changes in blood flow and blood oxygenation in superficial cortical blood vessels and tissue in response to drug-induced absence-like seizures, correlating motor behavior with changes in blood flow and blood oxygenation in the brain.

  6. Assessing balance through the use of a low-cost head-mounted display in older adults: a pilot study

    Directory of Open Access Journals (Sweden)

    Saldana SJ

    2017-08-01

    Full Text Available Santiago J Saldana,1 Anthony P Marsh,2 W Jack Rejeski,2 Jack K Haberl,2 Peggy Wu,3 Scott Rosenthal,4 Edward H Ip1 1Department of Biostatistical Sciences, Wake Forest School of Medicine, 2Department of Health and Exercise Science, Wake Forest University, Winston-Salem, NC, 3Research and Development, Smart Information Flow Technologies, Minneapolis, MN, 4Wake Forest School of Medicine, Winston-Salem, NC, USA Introduction: As the population ages, the prevention of falls is an increasingly important public health problem. Balance assessment forms an important component of fall-prevention programs for older adults. The recent development of cost-effective and highly responsive virtual reality (VR systems means new methods of balance assessment are feasible in a clinical setting. This proof-of-concept study made use of the submillimeter tracking built into modern VR head-mounted displays (VRHMDs to assess balance through the use of visual–vestibular conflict. The objective of this study was to evaluate the validity, acceptability, and reliability of using a VRHMD to assess balance in older adults.Materials and methods: Validity was assessed by comparing measurements from the VRHMD to measurements of postural sway from a force plate. Acceptability was assessed through the use of the Simulator Sickness Questionnaire pre- and postexposure to assess possible side effects of the visual–vestibular conflict. Reliability was assessed by measuring correlations between repeated measurements 1 week apart. Variables of possible importance that were found to be reliable (r≥0.9 between tests separated by a week were then tested for differences compared to a control group. Assessment was performed as a cross-sectional single-site community center-based study in 13 older adults (≥65 years old, 80.2±7.3 years old, 77% female, five at risk of falls, eight controls. The VR balance assessment consisted of four modules: a baseline module, a reaction module, a

  7. Simulated laparoscopy using a head-mounted display vs traditional video monitor: an assessment of performance and muscle fatigue.

    Science.gov (United States)

    Maithel, S K; Villegas, L; Stylopoulos, N; Dawson, S; Jones, D B

    2005-03-01

    The direction of visual gaze may be an important ergonomic factor that affects operative performance. We designed a study to determine whether a head-mounted display (HMD) worn by the surgeon would improve task performance and/or reduce muscle fatigue during a laparoscopic task when compared to the use of a traditional video monitor display (VMD). Surgical residents (n = 30) were enrolled in the study. A junior group, consisting of 15 postgraduate year (PGY) = 1 subjects with no previous laparoscopic experience, and a senior group, consisting of 15 PGY 4 and PGY 5 subjects with experience, completed a laparoscopic task that was repeated four times using the Computer Enhanced Laparoscopic Training System (CELTS). Groups alternated between using the HMD with the task placed in a downward frontal position and the VMD with the task at a 30 degrees lateral angle. The CELTS module assessed task completion time, depth perception, path length of instruments, response orientation, motion smoothness; the system then generated an overall score. Electromyography (EMG) was used to record sternocleidomastoid muscle activity. Display preference was surveyed. The senior residents performed better than the junior residents overall on all parameters (p < 0.05) except for motion smoothness, where there was no difference. In both groups, the HMD significantly improved motion smoothness when compared to the VMD (p < 0.05). All other parameters were equal. There was less muscle fatigue when using the VMD (p < 0.05). We found that 66% of the junior residents but only 20% of the senior residents preferred the HMD. The CELTS module demonstrated evidence of construct validity by differentiating the performances of junior and senior residents. By aligning the surgeon's visual gaze with the instruments, HMD improved smoothness of motion. Experienced residents preferred the traditional monitor display. Although the VMD produced less muscle fatigue, inexperienced residents preferred the HMD

  8. Piloting the feasibility of head-mounted video technology to augment student feedback during simulated clinical decision-making: An observational design pilot study.

    Science.gov (United States)

    Forbes, Helen; Bucknall, Tracey K; Hutchinson, Alison M

    2016-04-01

    Clinical decision-making is a complex activity that is critical to patient safety. Simulation, augmented by feedback, affords learners the opportunity to learn critical clinical decision-making skills. More detailed feedback following simulation exercises has the potential to further enhance student learning, particularly in relation to developing improved clinical decision-making skills. To investigate the feasibility of head-mounted video camera recordings, to augment feedback, following acute patient deterioration simulations. Pilot study using an observational design. Ten final-year nursing students participated in three simulation exercises, each focussed on detection and management of patient deterioration. Two observers collected behavioural data using an adapted version of Gaba's Clinical Simulation Tool, to provide verbal feedback to each participant, following each simulation exercise. Participants wore a head-mounted video camera during the second simulation exercise only. Video recordings were replayed to participants to augment feedback, following the second simulation exercise. Data were collected on: participant performance (observed and perceived); participant perceptions of feedback methods; and head-mounted video camera recording feasibility and capability for detailed audio-visual feedback. Management of patient deterioration improved for six participants (60%). Increased perceptions of confidence (70%) and competence (80%), were reported by the majority of participants. Few participants (20%) agreed that the video recording specifically enhanced their learning. The visual field of the head-mounted video camera was not always synchronised with the participant's field of vision, thus affecting the usefulness of some recordings. The usefulness of the video recordings, to enhance verbal feedback to participants on detection and management of simulated patient deterioration, was inconclusive. Modification of the video camera glasses, to improve

  9. Optoelectronic Mounting Structure

    Science.gov (United States)

    Anderson, Gene R.; Armendariz, Marcelino G.; Baca, Johnny R. F.; Bryan, Robert P.; Carson, Richard F.; Chu, Dahwey; Duckett, III, Edwin B.; McCormick, Frederick B.; Peterson, David W.; Peterson, Gary D.; Reber, Cathleen A.; Reysen, Bill H.

    2004-10-05

    An optoelectronic mounting structure is provided that may be used in conjunction with an optical transmitter, receiver or transceiver module. The mounting structure may be a flexible printed circuit board. Thermal vias or heat pipes in the head region may transmit heat from the mounting structure to the heat spreader. The heat spreader may provide mechanical rigidity or stiffness to the heat region. In another embodiment, an electrical contact and ground plane may pass along a surface of the head region so as to provide an electrical contact path to the optoelectronic devices and limit electromagnetic interference. In yet another embodiment, a window may be formed in the head region of the mounting structure so as to provide access to the heat spreader. Optoelectronic devices may be adapted to the heat spreader in such a manner that the devices are accessible through the window in the mounting structure.

  10. Cross-axis adaptation improves 3D vestibulo-ocular reflex alignment during chronic stimulation via a head-mounted multichannel vestibular prosthesis

    Science.gov (United States)

    Dai, Chenkai; Fridman, Gene Y.; Chiang, Bryce; Davidovics, Natan; Melvin, Thuy-Anh; Cullen, Kathleen E.; Della Santina, Charles C.

    2012-01-01

    By sensing three-dimensional (3D) head rotation and electrically stimulating the three ampullary branches of a vestibular nerve to encode head angular velocity, a multichannel vestibular prosthesis (MVP) can restore vestibular sensation to individuals disabled by loss of vestibular hair cell function. However, current spread to afferent fibers innervating non-targeted canals and otolith endorgans can distort the vestibular nerve activation pattern, causing misalignment between the perceived and actual axis of head rotation. We hypothesized that over time, central neural mechanisms can adapt to correct this misalignment. To test this, we rendered five chinchillas vestibular-deficient via bilateral gentamicin treatment and unilaterally implanted them with a head mounted MVP. Comparison of 3D angular vestibulo-ocular reflex (aVOR) responses during 2 Hz, 50°/s peak horizontal sinusoidal head rotations in darkness on the first, third and seventh days of continual MVP use revealed that eye responses about the intended axis remained stable (at about 70% of the normal gain) while misalignment improved significantly by the end of one week of prosthetic stimulation. A comparable time course of improvement was also observed for head rotations about the other two semicircular canal axes and at every stimulus frequency examined (0.2–5 Hz). In addition, the extent of disconjugacy between the two eyes progressively improved during the same time window. These results indicate that the central nervous system rapidly adapts to multichannel prosthetic vestibular stimulation to markedly improve 3D aVOR alignment within the first week after activation. Similar adaptive improvements are likely to occur in other species, including humans. PMID:21374081

  11. Evaluating the image quality of Closed Circuit Television magnification systems versus a head-mounted display for people with low vision. .

    Science.gov (United States)

    Lin, Chern Sheng; Jan, Hvey-An; Lay, Yun-Long; Huang, Chih-Chia; Chen, Hsien-Tse

    2014-01-01

    In this research, image analysis was used to optimize the visual output of a traditional Closed Circuit Television (CCTV) magnifying system and a head-mounted display (HMD) for people with low vision. There were two purposes: (1) To determine the benefit of using an image analysis system to customize image quality for a person with low vision, and (2) to have people with low vision evaluate a traditional CCTV magnifier and an HMD, each customized to the user's needs and preferences. A CCTV system can electronically alter images by increasing the contrast, brightness, and magnification for the visually disabled when they are reading texts and pictures. The test methods was developed to evaluate and customize a magnification system for persons with low vision. The head-mounted display with CCTV was used to obtain better depth of field and a higher modulation transfer function from the video camera. By sensing the parameters of the environment (e.g., ambient light level, etc.) and collecting the user's specific characteristics, the system could make adjustments according to the user's needs, thus allowing the visually disabled to read more efficiently.

  12. Breath-hold monitoring and visual feedback for radiotherapy using a charge-coupled device camera and a head-mounted display. System development and feasibility

    International Nuclear Information System (INIS)

    Yoshitake, Tadamasa; Nakamura, Katsumasa; Shioyama, Yoshiyuki

    2008-01-01

    The aim of this study was to present the technical aspects of the breath-hold technique with respiratory monitoring and visual feedback and to evaluate the feasibility of this system in healthy volunteers. To monitor respiration, the vertical position of the fiducial marker placed on the patient's abdomen was tracked by a machine vision system with a charge-coupled device camera. A monocular head-mounted display was used to provide the patient with visual feedback about the breathing trace. Five healthy male volunteers were enrolled in this study. They held their breath at the end-inspiration and the end-expiration phases. They performed five repetitions of the same type of 15-s breath-holds with and without a head-mounted display, respectively. A standard deviation of five mean positions of the fiducial marker during a 15-s breath-hold in each breath-hold type was used as the reproducibility value of breath-hold. All five volunteers well tolerated the breath-hold maneuver. For the inspiration breath-hold, the standard deviations with and without visual feedback were 1.74 mm and 0.84 mm, respectively (P=0.20). For the expiration breath-hold, the standard deviations with and without visual feedback were 0.63 mm and 0.96 mm, respectively (P=0.025). Our newly developed system might help the patient achieve improved breath-hold reproducibility. (author)

  13. Development and Design of Next-Generation Head-Mounted Ambulatory Microdose Positron-Emission Tomography (AM-PET System

    Directory of Open Access Journals (Sweden)

    Samantha Melroy

    2017-05-01

    Full Text Available Several applications exist for a whole brain positron-emission tomography (PET brain imager designed as a portable unit that can be worn on a patient’s head. Enabled by improvements in detector technology, a lightweight, high performance device would allow PET brain imaging in different environments and during behavioral tasks. Such a wearable system that allows the subjects to move their heads and walk—the Ambulatory Microdose PET (AM-PET—is currently under development. This imager will be helpful for testing subjects performing selected activities such as gestures, virtual reality activities and walking. The need for this type of lightweight mobile device has led to the construction of a proof of concept portable head-worn unit that uses twelve silicon photomultiplier (SiPM PET module sensors built into a small ring which fits around the head. This paper is focused on the engineering design of mechanical support aspects of the AM-PET project, both of the current device as well as of the coming next-generation devices. The goal of this work is to optimize design of the scanner and its mechanics to improve comfort for the subject by reducing the effect of weight, and to enable diversification of its applications amongst different research activities.

  14. Development and Design of Next-Generation Head-Mounted Ambulatory Microdose Positron-Emission Tomography (AM-PET) System.

    Science.gov (United States)

    Melroy, Samantha; Bauer, Christopher; McHugh, Matthew; Carden, Garret; Stolin, Alexander; Majewski, Stan; Brefczynski-Lewis, Julie; Wuest, Thorsten

    2017-05-19

    Several applications exist for a whole brain positron-emission tomography (PET) brain imager designed as a portable unit that can be worn on a patient's head. Enabled by improvements in detector technology, a lightweight, high performance device would allow PET brain imaging in different environments and during behavioral tasks. Such a wearable system that allows the subjects to move their heads and walk-the Ambulatory Microdose PET (AM-PET)-is currently under development. This imager will be helpful for testing subjects performing selected activities such as gestures, virtual reality activities and walking. The need for this type of lightweight mobile device has led to the construction of a proof of concept portable head-worn unit that uses twelve silicon photomultiplier (SiPM) PET module sensors built into a small ring which fits around the head. This paper is focused on the engineering design of mechanical support aspects of the AM-PET project, both of the current device as well as of the coming next-generation devices. The goal of this work is to optimize design of the scanner and its mechanics to improve comfort for the subject by reducing the effect of weight, and to enable diversification of its applications amongst different research activities.

  15. A comparison of head-mounted and hand-held displays for 360° videos with focus on attitude and behavior change

    DEFF Research Database (Denmark)

    Fonseca, Diana; Kraus, Martin

    2016-01-01

    The present study is designed to test how immersion, presence, and narrative content (with a focus on emotional immersion) can affect one's pro-environmental attitude and behavior with specific interest in 360° videos and meat consumption as a non pro-environmental behavior. This research describes...... a between-group design experiment that compares two systems with different levels of immersion and two types of narratives, one with and one without emotional content. In the immersive video (IV) condition (high immersion), 21 participants used a Head-Mounted Display (HMD) to watch an emotional 360° video...... about meat consumption and its effects on the environment; another 21 participants experienced the tablet condition (low immersion) where they viewed the same video but with a 10.1 inch tablet; 22 participants in the control condition viewed a non emotional video about submarines with an HMD...

  16. Effects of videogame distraction and a virtual reality type head-mounted display helmet on cold pressor pain in young elementary school-aged children.

    Science.gov (United States)

    Dahlquist, Lynnda M; Weiss, Karen E; Law, Emily F; Sil, Soumitri; Herbert, Linda Jones; Horn, Susan Berrin; Wohlheiter, Karen; Ackerman, Claire Sonntag

    2010-07-01

    This study examined the effects of videogame distraction and a virtual reality (VR) type head-mounted display helmet for children undergoing cold pressor pain. Fifty children between the ages of 6 and 10 years underwent a baseline cold pressor trial followed by two cold pressor trials in which interactive videogame distraction was delivered via a VR helmet or without a VR helmet in counterbalanced order. As expected, children demonstrated significant improvements in pain threshold and pain tolerance during both distraction conditions. However, the two distraction conditions did not differ in effectiveness. Using the VR helmet did not result in improved pain tolerance over and above the effects of interactive videogame distraction without VR technology. Clinical implications and possible developmental differences in elementary school-aged children's ability to use VR technology are discussed.

  17. Comparison of optical see-through head-mounted displays for surgical interventions with object-anchored 2D-display.

    Science.gov (United States)

    Qian, Long; Barthel, Alexander; Johnson, Alex; Osgood, Greg; Kazanzides, Peter; Navab, Nassir; Fuerst, Bernhard

    2017-06-01

    Optical see-through head-mounted displays (OST-HMD) feature an unhindered and instantaneous view of the surgery site and can enable a mixed reality experience for surgeons during procedures. In this paper, we present a systematic approach to identify the criteria for evaluation of OST-HMD technologies for specific clinical scenarios, which benefit from using an object-anchored 2D-display visualizing medical information. Criteria for evaluating the performance of OST-HMDs for visualization of medical information and its usage are identified and proposed. These include text readability, contrast perception, task load, frame rate, and system lag. We choose to compare three commercially available OST-HMDs, which are representatives of currently available head-mounted display technologies. A multi-user study and an offline experiment are conducted to evaluate their performance. Statistical analysis demonstrates that Microsoft HoloLens performs best among the three tested OST-HMDs, in terms of contrast perception, task load, and frame rate, while ODG R-7 offers similar text readability. The integration of indoor localization and fiducial tracking on the HoloLens provides significantly less system lag in a relatively motionless scenario. With ever more OST-HMDs appearing on the market, the proposed criteria could be used in the evaluation of their suitability for mixed reality surgical intervention. Currently, Microsoft HoloLens may be more suitable than ODG R-7 and Epson Moverio BT-200 for clinical usability in terms of the evaluated criteria. To the best of our knowledge, this is the first paper that presents a methodology and conducts experiments to evaluate and compare OST-HMDs for their use as object-anchored 2D-display during interventions.

  18. Implementation of an Ultra-Bright Thermographic Phosphor for Gas Turbine Engine Temperature Measurements

    Science.gov (United States)

    Eldridge, Jeffrey I.; Bencic, Timothy J.; Zhu, Dongming; Cuy, Michael D.; Wolfe, Douglas E.; Allison, Stephen W.; Beshears, David L.; Jenkins, Thomas P.; Heeg, Bauke; Howard, Robert P.; hide

    2014-01-01

    The overall goal of the Aeronautics Research Mission Directorate (ARMD) Seedling Phase II effort was to build on the promising temperature-sensing characteristics of the ultrabright thermographic phosphor Cr-doped gadolinium aluminum perovskite (Cr:GAP) demonstrated in Phase I by transitioning towards an engine environment implementation. The strategy adopted was to take advantage of the unprecedented retention of ultra-bright luminescence from Cr:GAP at temperatures over 1000 C to enable fast 2D temperature mapping of actual component surfaces as well as to utilize inexpensive low-power laser-diode excitation suitable for on-wing diagnostics. A special emphasis was placed on establishing Cr:GAP luminescence-based surface temperature mapping as a new tool for evaluating engine component surface cooling effectiveness.

  19. Clinical introduction of a linac head-mounted 2D detector array based quality assurance system in head and neck IMRT

    International Nuclear Information System (INIS)

    Korevaar, Erik W.; Wauben, David J.L.; Hulst, Peter C. van der; Langendijk, Johannes A.; Veld, Aart A. van't

    2011-01-01

    Background and purpose: IMRT QA is commonly performed in a phantom geometry but the clinical interpretation of the results in a 2D phantom plane is difficult. The main objective of our work is to move from film measurement based QA to 3D dose reconstruction in a patient CT scan. In principle, this could be achieved using a dose reconstruction method from 2D detector array measurements as available in the COMPASS system (IBA Dosimetry). The first step in the clinical introduction of this system instead of the currently used film QA procedures is to test the reliability of the dose reconstruction. In this paper we investigated the validation of the method in a homogeneous phantom with the film QA procedure as a reference. We tested whether COMPASS QA results correctly identified treatment plans that did or did not fulfil QA requirements in head and neck (H and N) IMRT. Materials and methods: A total number of 24 treatments were selected from an existing database with more than 100 film based H and N IMRT QA results. The QA results were classified as either good, just acceptable or clinically rejected (mean gamma index 0.5, respectively with 3%/3 mm criteria). Film QA was repeated and compared to COMPASS QA with a MatriXX detector measurement performed on the same day. Results: Good agreement was found between COMPASS reconstructed dose and film measured dose in a phantom (mean gamma 0.83 ± 0.09, 1SD with 1%/1 mm criteria, 0.33 ± 0.04 with 3%/3 mm criteria). COMPASS QA results correlated well with film QA, identifying the same patients with less good QA results. Repeated measurements with film and COMPASS showed changes in delivery after a modified MLC calibration, also visible in a standard MLC check in COMPASS. The time required for QA reduced by half by using COMPASS instead of film. Conclusions: Agreement of COMPASS QA results with film based QA supports its clinical introduction for a phantom geometry. A standard MLC calibration check is sensitive to <1 mm

  20. Scintillation crystal mounting apparatus

    International Nuclear Information System (INIS)

    Engdahl, L.W.; Deans, A.J.

    1982-01-01

    An improved detector head for a gamma camera is disclosed. The detector head includes a housing and a detector assembly mounted within the housing. Components of the detector assembly include a crystal sub-assembly, a phototube array, and a light pipe between the phototube array and crystal sub-assembly. The invention provides a unique structure for maintaining the phototubes in optical relationship with the light pipe and preventing the application of forces that would cause the camera's crystal to crack

  1. A fully automated calibration method for an optical see-through head-mounted operating microscope with variable zoom and focus.

    Science.gov (United States)

    Figl, Michael; Ede, Christopher; Hummel, Johann; Wanschitz, Felix; Ewers, Rolf; Bergmann, Helmar; Birkfellner, Wolfgang

    2005-11-01

    Ever since the development of the first applications in image-guided therapy (IGT), the use of head-mounted displays (HMDs) was considered an important extension of existing IGT technologies. Several approaches to utilizing HMDs and modified medical devices for augmented reality (AR) visualization were implemented. These approaches include video-see through systems, semitransparent mirrors, modified endoscopes, and modified operating microscopes. Common to all these devices is the fact that a precise calibration between the display and three-dimensional coordinates in the patient's frame of reference is compulsory. In optical see-through devices based on complex optical systems such as operating microscopes or operating binoculars-as in the case of the system presented in this paper-this procedure can become increasingly difficult since precise camera calibration for every focus and zoom position is required. We present a method for fully automatic calibration of the operating binocular Varioscope M5 AR for the full range of zoom and focus settings available. Our method uses a special calibration pattern, a linear guide driven by a stepping motor, and special calibration software. The overlay error in the calibration plane was found to be 0.14-0.91 mm, which is less than 1% of the field of view. Using the motorized calibration rig as presented in the paper, we were also able to assess the dynamic latency when viewing augmentation graphics on a mobile target; spatial displacement due to latency was found to be in the range of 1.1-2.8 mm maximum, the disparity between the true object and its computed overlay represented latency of 0.1 s. We conclude that the automatic calibration method presented in this paper is sufficient in terms of accuracy and time requirements for standard uses of optical see-through systems in a clinical environment.

  2. Three-dimensional head-mounted gaming task procedure maximizes effects of vestibular rehabilitation in unilateral vestibular hypofunction: a randomized controlled pilot trial.

    Science.gov (United States)

    Micarelli, Alessandro; Viziano, Andrea; Augimeri, Ivan; Micarelli, Domenico; Alessandrini, Marco

    2017-12-01

    Considering the emerging advantages related to virtual reality implementation in clinical rehabilitation, the aim of the present study was to discover possible (i) improvements achievable in unilateral vestibular hypofunction patients using a self-assessed head-mounted device (HMD)-based gaming procedure when combined with a classical vestibular rehabilitation protocol (HMD group) as compared with a group undergoing only vestibular rehabilitation and (ii) HMD procedure-related side effects. Therefore, 24 vestibular rehabilitation and 23-matched HMD unilateral vestibular hypofunction individuals simultaneously underwent a 4-week rehabilitation protocol. Both otoneurological measures (vestibulo-ocular reflex gain and postural arrangement by studying both posturography parameters and spectral values of body oscillation) and performance and self-report measures (Italian Dizziness Handicap Inventory; Activities-specific Balance Confidence scale; Zung Instrument for Anxiety Disorders, Dynamic Gait Index; and Simulator Sickness Questionnaire) were analyzed by means of a between-group/within-subject analysis of variance model. A significant post-treatment between-effect was found, and the HMD group demonstrated an overall improvement in vestibulo-ocular reflex gain on the lesional side, in posturography parameters, in low-frequency spectral domain, as well as in Italian Dizziness Handicap Inventory and Activities-specific Balance Confidence scale scores. Meanwhile, Simulator Sickness Questionnaire scores demonstrated a significant reduction in symptoms related to experimental home-based gaming tasks during the HMD procedure. Our findings revealed the possible advantages of HMD implementation in vestibular rehabilitation, suggesting it as an innovative, self-assessed, low-cost, and compliant tool useful in maximizing vestibular rehabilitation outcomes.

  3. Effectiveness of recycling light in ultra-bright short-arc discharge lamps.

    Science.gov (United States)

    Malul, Asher; Nakar, Doron; Feuermann, Daniel; Gordon, Jeffrey M

    2007-10-17

    Recycling light back into a plasma lamp's radiant zone can enhance its radiance. Measurements are reported for the effectiveness, spectral properties and modified plasma radiance maps that result from light recycling with a specular hemispherical mirror in commercial 150 W ultrabright Xenon short-arc discharge lamps, motivated by projection, biomedical and high-temperature furnace applications. For certain spectral windows and plasma arc regions, radiance can be heightened by up to 70%. However, the overall light recycling efficiency is reduced to about half this value due to lamp geometry. The manner in which light-plasma interactions affect light recycling efficacy is also elucidated.

  4. Entangling quantum-logic gate operated with an ultrabright semiconductor single-photon source.

    Science.gov (United States)

    Gazzano, O; Almeida, M P; Nowak, A K; Portalupi, S L; Lemaître, A; Sagnes, I; White, A G; Senellart, P

    2013-06-21

    We demonstrate the unambiguous entangling operation of a photonic quantum-logic gate driven by an ultrabright solid-state single-photon source. Indistinguishable single photons emitted by a single semiconductor quantum dot in a micropillar optical cavity are used as target and control qubits. For a source brightness of 0.56 photons per pulse, the measured truth table has an overlap with the ideal case of 68.4±0.5%, increasing to 73.0±1.6% for a source brightness of 0.17 photons per pulse. The gate is entangling: At a source brightness of 0.48, the Bell-state fidelity is above the entangling threshold of 50% and reaches 71.0±3.6% for a source brightness of 0.15.

  5. Ultrabright narrow-band telecom two-photon source for long-distance quantum communication

    Science.gov (United States)

    Niizeki, Kazuya; Ikeda, Kohei; Zheng, Mingyang; Xie, Xiuping; Okamura, Kotaro; Takei, Nobuyuki; Namekata, Naoto; Inoue, Shuichiro; Kosaka, Hideo; Horikiri, Tomoyuki

    2018-04-01

    We demonstrate an ultrabright narrow-band two-photon source at the 1.5 µm telecom wavelength for long-distance quantum communication. By utilizing a bow-tie cavity, we obtain a cavity enhancement factor of 4.06 × 104. Our measurement of the second-order correlation function G (2)(τ) reveals that the linewidth of 2.4 MHz has been hitherto unachieved in the 1.5 µm telecom band. This two-photon source is useful for obtaining a high absorption probability close to unity by quantum memories set inside quantum repeater nodes. Furthermore, to the best of our knowledge, the observed spectral brightness of 3.94 × 105 pairs/(s·MHz·mW) is also the highest reported over all wavelengths.

  6. Application of vibro-acoustical studies in process of improving dependability of arm-mounted cutter-heads of KGSA-320 shearers

    Energy Technology Data Exchange (ETDEWEB)

    Zakrzewski, T; Sikora, W

    1986-01-01

    Discusses application of acoustic vibration measurements in maintenance of mining machines. A formula is given for the dimensionless directional discriminant using which the technical state of shearer loader cutting heads can be assessed. KGS-320 shearer cutting drums were investigated at suitable points characterized by maximum deviations from zero reference values. Measurements were carried out in idle-run conditions and are given in graphs: distribution of changes in peak directivity coefficient deviation value for vibration displacement in relation to order number N of cutter head as well as location of measurement point; and distribution of changes in peak directivity coefficient deviation value for vibration velocity in relation to order number N of cutter head and location of the measurement point. An aim is to develop classification criteria for vibration acoustic diagnostics and to use the method for designing and manufacturing machines. 12 refs.

  7. DETECTION OF AN ULTRA-BRIGHT SUBMILLIMETER GALAXY BEHIND THE SMALL MAGELLANIC CLOUD

    Energy Technology Data Exchange (ETDEWEB)

    Takekoshi, Tatsuya; Minamidani, Tetsuhiro; Sorai, Kazuo; Habe, Asao [Department of Cosmosciences, Graduate School of Science, Hokkaido University, Sapporo 060-0810 (Japan); Tamura, Yoichi; Kohno, Kotaro [Institute of Astronomy, University of Tokyo, Osawa, Mitaka, Tokyo 181-0015 (Japan); Oogi, Taira [Department of Physics, Faculty of Science, Hokkaido University, Sapporo 060-0810 (Japan); Ezawa, Hajime; Komugi, Shinya; Mizuno, Norikazu; Muller, Erik; Kawamura, Akiko [Chile Observatory, National Astronomical Observatory, Mitaka, Tokyo 181-8588 (Japan); Oshima, Tai [Nobeyama Radio Observatory, National Astronomical Observatory of Japan, Minamimaki, Minamisaku, Nagano 384-1305 (Japan); Scott, Kimberly S. [North American ALMA Science Center, National Radio Astronomy Observatory, Charlottesville, VA 22903 (United States); Austermann, Jason E. [Center for Astrophysics and Space Astronomy, University of Colorado, Boulder, CO 80309 (United States); Tosaki, Tomoka [Joetsu University of Education, Joetsu, Niigata 943-8512 (Japan); Onishi, Toshikazu [Department of Physical Science, Osaka Prefecture University, Gakuen 1-1, Sakai, 599-8531 Osaka (Japan); Fukui, Yasuo [Department of Astrophysics, Nagoya University, Chikusa-ku, Nagoya 464-8602 (Japan); Matsuo, Hiroshi [Advanced Technology Center, National Astronomical Observatory of Japan, Mitaka, Tokyo 181-8588 (Japan); Aretxaga, Itziar [Instituto Nacional de Astrofisica, Optica y Electronica (INAOE), 72000 Puebla (Mexico); and others

    2013-09-10

    We report the discovery of a new ultra-bright submillimeter galaxy (SMG) behind the Small Magellanic Cloud (SMC). This SMG is detected as a 43.3 {+-} 8.4 mJy point source (MM J01071-7302, hereafter MMJ0107) in the 1.1 mm continuum survey of the SMC by AzTEC on the ASTE telescope. MMJ0107 is also detected in the radio (843 MHz), Herschel/SPIRE, Spitzer MIPS 24 {mu}m, all IRAC bands, Wide-field Infrared Survey Explorer, and near-infrared (J, H, K{sub S} ). We find an optical (U, B, V) source, which might be the lensing object, at a distance of 1.''4 from near-infrared and IRAC sources. Photometric redshift estimates for the SMG using representative spectral energy distribution templates show the redshifts of 1.4-3.9. We estimate total far-infrared luminosity of (0.3-2.2) Multiplication-Sign 10{sup 14} {mu}{sup -1} L{sub Sun} and a star formation rate of 5600-39, 000 {mu}{sup -1} M{sub Sun} yr{sup -1}, where {mu} is the gravitational magnification factor. This apparent extreme star formation activity is likely explained by a highly magnified gravitational lens system.

  8. Ultra-bright emission from hexagonal boron nitride defects as a new platform for bio-imaging and bio-labelling

    Science.gov (United States)

    Elbadawi, Christopher; Tran, Trong Toan; Shimoni, Olga; Totonjian, Daniel; Lobo, Charlene J.; Grosso, Gabriele; Moon, Hyowan; Englund, Dirk R.; Ford, Michael J.; Aharonovich, Igor; Toth, Milos

    2016-12-01

    Bio-imaging requires robust ultra-bright probes without causing any toxicity to the cellular environment, maintain their stability and are chemically inert. In this work we present hexagonal boron nitride (hBN) nanoflakes which exhibit narrowband ultra-bright single photon emitters1. The emitters are optically stable at room temperature and under ambient environment. hBN has also been noted to be noncytotoxic and seen significant advances in functionalization with biomolecules2,3. We further demonstrate two methods of engineering this new range of extremely robust multicolour emitters across the visible and near infrared spectral ranges for large scale sensing and biolabeling applications.

  9. Discovery of a Lensed Ultrabright Submillimeter Galaxy at z = 2.0439

    Science.gov (United States)

    Díaz-Sánchez, A.; Iglesias-Groth, S.; Rebolo, R.; Dannerbauer, H.

    2017-07-01

    We report an ultrabright lensed submillimeter galaxy (SMG) at z = 2.0439, WISE J132934.18+224327.3, identified as a result of a full-sky cross-correlation of the AllWISE and Planck compact source catalogs aimed to search for bright analogs of the SMG SMM J2135, the Cosmic Eyelash. Inspection of archival SCUBA-2 observations of the candidates revealed a source with fluxes ({S}850μ {{m}}=130 mJy) consistent with the Planck measurements. The centroid of the SCUBA-2 source coincides within 1 arcsec with the position of the AllWISE mid-IR source, and, remarkably, with an arc-shaped lensed galaxy in HST images at visible wavelengths. Low-resolution rest-frame UV-optical spectroscopy of this lensed galaxy obtained with 10.4 m GTC reveals the typical absorption lines of a starburst galaxy. Gemini-N near-IR spectroscopy provided a clear detection of {{{H}}}α emission. The lensed source appears to be gravitationally magnified by a massive foreground galaxy cluster lens at z = 0.44 modeling with Lenstool indicates a lensing amplification factor of 11 ± 2. We determine an intrinsic rest-frame 8-1000 μm luminosity, {L}{IR}, of (1.3+/- 0.1)× {10}13 {L}⊙ , and a likely star formation rate (SFR) of ˜ 500{--}2000 {M}⊙ {{yr}}-1. The SED shows a remarkable similarity with the Cosmic Eyelash from optical-mid/IR to submillimeter/radio, albeit at higher fluxes.

  10. Ultrabright, narrow-band photon-pair source for atomic quantum memories

    Science.gov (United States)

    Tsai, Pin-Ju; Chen, Ying-Cheng

    2018-06-01

    We demonstrate an ultrabright, narrow-band and frequency-tunable photon-pair source based on cavity-enhanced spontaneous parametric down conversion (SPDC) which is compatible with atomic transition of rubidium D 2-line (780 nm) or cesium D 2-line (852 nm). With the pump beam alternating between a high and a low power phase, the output is switching between the optical parametric oscillator (OPO) and photon-pair generation mode. We utilize the OPO output light to lock the cavity length to maintain the double resonances of signal and idler, as well as to lock the signal frequency to cesium atomic transition. With a type-II phase matching and a double-passed pump scheme such that the cluster frequency spacing is larger than the SPDC bandwidth, the photon-pair output is in a nearly single-mode operation as confirmed by a scanning Fabry–Perot interferometer with its output detected by a photomultiplier. The achieved generation and detection rates are 7.24× {10}5 and 6142 s‑1 mW‑1, respectively. The correlation time of the photon pair is 21.6(2.2) ns, corresponding to a bandwidth of 2π × 6.6(6) MHz. The spectral brightness is 1.06× {10}5 s‑1 mW‑1 MHz‑1. This is a relatively high value under a single-mode operation with the cavity-SPDC scheme. The generated single photons can be readily used in experiments related to atomic quantum memories.

  11. Reactor head shielding apparatus

    International Nuclear Information System (INIS)

    Schukei, G.E.; Roebelen, G.J.

    1992-01-01

    This patent describes a nuclear reactor head shielding apparatus for mounting on spaced reactor head lifting members radially inwardly of the head bolts. It comprises a frame of sections for mounting on the lifting members and extending around the top central area of the head, mounting means for so mounting the frame sections, including downwardly projecting members on the frame sections and complementary upwardly open recessed members for fastening to the lifting members for receiving the downwardly projecting members when the frame sections are lowered thereto with lead shielding supported thereby on means for hanging lead shielding on the frame to minimize radiation exposure or personnel working with the head bolts or in the vicinity thereof

  12. Ultrabright multikilovolt x-ray source: saturated amplification on noble gas transition arrays from hollow atom states

    Science.gov (United States)

    Rhodes, Charles K.; Boyer, Keith

    2004-02-17

    An apparatus and method for the generation of ultrabright multikilovolt x-rays from saturated amplification on noble gas transition arrays from hollow atom states is described. Conditions for x-ray amplification in this spectral region combine the production of cold, high-Z matter, with the direct, selective multiphoton excitation of hollow atoms from clusters using ultraviolet radiation and a nonlinear mode of confined, self-channeled propagation in plasmas. Data obtained is consistent with the presence of saturated amplification on several transition arrays of the hollow atom Xe(L) spectrum (.lambda..about.2.9 .ANG.). An estimate of the peak brightness achieved is .about.10.sup.29 .gamma..multidot.s.sup.-1.multidot.mm.sup.-2.multidot.mr.sup.-2 (0.1% Bandwidth).sup.-1, that is .about.10.sup.5 -fold higher than presently available synchotron technology.

  13. Direct observations of cracks and voids in structural materials by X-ray imaging using ultra-bright synchrotron radiation

    International Nuclear Information System (INIS)

    Nakayama, Takenori; Yuse, Fumio; Tsubokawa, Yoshiyuki; Matsui, Junji

    2003-01-01

    Refraction contrast X-ray imaging experiments were conducted on acrylic resin with an artificial cylindrical hole, A7075 aluminum alloy, A6063 aluminum castings, mild steel with cracks or voids, and low alloy steel with inclusions, using a ultra-bright synchrotron radiation X-ray beam in BL24XU hutch C of SPring-8. Conventional absorption contrast X-ray imaging experiments were also done for the comparison. The X-ray beam was controlled to be monochromatic by Si double-crystals and collimated by a slit. The distance between the sample and the detector was changed from 0 to 3 m, and the X-ray energy was 15 to 25 keV. Photographs were taken by X-ray film and/or X-ray CCD camera. As a result, the refraction imaging method gave a much more distinct image of the artificial cylindrical hole in acrylic resin as compared with the absorption method. The fatigue cracks in aluminum alloy and mild steel were also distinctly observed. The X-ray imaging revealed the presence of MnS nonmetallic inclusions in low alloy steel. Void defects in aluminum castings were clearly detected by the imaging. In addition, in-situ observation of tensile fracture of aluminum alloys using a high resolution X-ray CCD camera system wa successfully conducted. The observations by use of asymmetric reflection technique for X-ray imaging experiment were also well performed. From above, the X-ray imaging method using ultra-bright synchrotron radiation is concluded to be very useful for fracture research of materials. (author)

  14. Direct observations of cracks and voids in structural materials by X-ray imaging using ultra-bright synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Takenori; Yuse, Fumio [Kobe Steel, Ltd., Materials Research Laboratory, Kobe, Hyogo (Japan); Tsubokawa, Yoshiyuki [Kobelco Research Inst., Kobe, Hyogo (Japan); Matsui, Junji [Himeji Inst. of Technology, Kamigori, Hyogo (Japan)

    2003-04-01

    Refraction contrast X-ray imaging experiments were conducted on acrylic resin with an artificial cylindrical hole, A7075 aluminum alloy, A6063 aluminum castings, mild steel with cracks or voids, and low alloy steel with inclusions, using a ultra-bright synchrotron radiation X-ray beam in BL24XU hutch C of SPring-8. Conventional absorption contrast X-ray imaging experiments were also done for the comparison. The X-ray beam was controlled to be monochromatic by Si double-crystals and collimated by a slit. The distance between the sample and the detector was changed from 0 to 3 m, and the X-ray energy was 15 to 25 keV. Photographs were taken by X-ray film and/or X-ray CCD camera. As a result, the refraction imaging method gave a much more distinct image of the artificial cylindrical hole in acrylic resin as compared with the absorption method. The fatigue cracks in aluminum alloy and mild steel were also distinctly observed. The X-ray imaging revealed the presence of MnS nonmetallic inclusions in low alloy steel. Void defects in aluminum castings were clearly detected by the imaging. In addition, in-situ observation of tensile fracture of aluminum alloys using a high resolution X-ray CCD camera system wa successfully conducted. The observations by use of asymmetric reflection technique for X-ray imaging experiment were also well performed. From above, the X-ray imaging method using ultra-bright synchrotron radiation is concluded to be very useful for fracture research of materials. (author)

  15. PV module mounting method and mounting assembly

    Science.gov (United States)

    Lenox, Carl J.S.; Johnson, Kurt M.

    2013-04-23

    A method for mounting PV modules to a deck includes selecting PV module layout pattern so that adjacent PV module edges are spaced apart. PV mounting and support assemblies are secured to the deck according to the layout pattern using fasteners extending into the deck. The PV modules are placed on the PV mounting and support assemblies. Retaining elements are located over and secured against the upper peripheral edge surfaces of the PV modules so to secure them to the deck with the peripheral edges of the PV modules spaced apart from the deck. In some examples a PV module mounting assembly, for use on a shingled deck, comprises flashing, a base mountable on the flashing, a deck-penetrating fastener engageable with the base and securable to the deck so to secure the flashing and the base to the shingled deck, and PV module mounting hardware securable to the base.

  16. Magnetic core mounting system

    Science.gov (United States)

    Ronning, Jeffrey J.

    2002-01-01

    A mounting apparatus for an electromagnetic device such as a transformer of inductor includes a generally planar metallic plate as a first heat sink, and a metallic mounting cup as a second heat sink. The mounting cup includes a cavity configured to receive the electromagnetic device, the cavity being defined by a base, and an axially-extending annular sidewall extending from the base to a flange portion of the mounting cup. The mounting cup includes first and second passages for allowing the leads of first and second windings of the electromagnetic device to be routed out of the cavity. The cavity is filled with a polyurethane potting resin, and the mounting cup, including the potted electromagnetic device, is mounted to the plate heat sink using fasteners. The mounting cup, which surrounds the electromagnetic device, in combination with the potting resin provides improved thermal transfer to the plate heat sink, as well as providing resistance to vibration and shocks.

  17. Photovoltaic module mounting system

    Science.gov (United States)

    Miros, Robert H. J. [Fairfax, CA; Mittan, Margaret Birmingham [Oakland, CA; Seery, Martin N [San Rafael, CA; Holland, Rodney H [Novato, CA

    2012-04-17

    A solar array mounting system having unique installation, load distribution, and grounding features, and which is adaptable for mounting solar panels having no external frame. The solar array mounting system includes flexible, pedestal-style feet and structural links connected in a grid formation on the mounting surface. The photovoltaic modules are secured in place via the use of attachment clamps that grip the edge of the typically glass substrate. The panel mounting clamps are then held in place by tilt brackets and/or mid-link brackets that provide fixation for the clamps and align the solar panels at a tilt to the horizontal mounting surface. The tilt brackets are held in place atop the flexible feet and connected link members thus creating a complete mounting structure.

  18. Liner mounting assembly

    Science.gov (United States)

    Halila, Ely E. (Inventor)

    1994-01-01

    A mounting assembly includes an annular supporting flange disposed coaxially about a centerline axis which has a plurality of circumferentially spaced apart supporting holes therethrough. An annular liner is disposed coaxially with the supporting flange and includes a plurality of circumferentially spaced apart mounting holes aligned with respective ones of the supporting holes. Each of a plurality of mounting pins includes a proximal end fixedly joined to the supporting flange through a respective one of the supporting holes, and a distal end disposed through a respective one of the liner mounting holes for supporting the liner to the supporting flange while unrestrained differential thermal movement of the liner relative to the supporting flange.

  19. An ultra-bright white LED based non-contact skin cancer imaging system with polarization control

    Science.gov (United States)

    Günther, A.; Basu, C.; Roth, B.; Meinhardt-Wollweber, M.

    2013-06-01

    Early detection and excision of melanoma skin cancer is crucial for a successful therapy. Dermoscopy in direct contact with the skin is routinely used for inspection, but screening is time consuming for high-risk patients with a large number of nevi. Features like symmetry, border, color and most importantly changes like growth or depigmentation of a nevus may indicate malignancy. We present a non-contact remote imaging system for human melanocytic nevi with homogenous illumination by an ultra-bright white LED. The advantage compared to established dermoscopy systems requiring direct skin contact is that deformation of raised nevi is avoided and full-body scans of the patients may time-efficiently be obtained while they are in a lying, comfortable position. This will ultimately allow for automated screening in the future. In addition, calibration of true color rendering, which is essential for distinguishing between benign and malignant lesions and to ensure reproducibility and comparison between individual check-ups in order to follow nevi evolution is implemented as well as suppression of specular highlights on the skin surface by integration of polarizing filters. Important features of the system which will be crucial for future integration into automated systems are the possibility to record images without artifacts in combination with short exposure times which both reduce image blurring caused by patient motion.

  20. Internally Mounting Strain Gages

    Science.gov (United States)

    Jett, J. R., Jr.

    1984-01-01

    Technique for mounting strain gages inside bolt or cylinder simultaneously inserts gage, attached dowel segment, and length of expandable tubing. Expandable tubing holds gage in place while adhesive cures, assuring even distribution of pressure on gage and area gaged.

  1. Mounting for ceramic scroll

    Science.gov (United States)

    Petty, Jack D.

    1993-01-01

    A mounting for a ceramic scroll on a metal engine block of a gas turbine engine includes a first ceramic ring and a pair of cross key connections between the first ceramic ring, the ceramic scroll, and the engine block. The cross key connections support the scroll on the engine block independent of relative radial thermal growth and for bodily movement toward an annular mounting shoulder on the engine. The scroll has an uninterrupted annular shoulder facing the mounting shoulder on the engine block. A second ceramic ring is captured between mounting shoulder and the uninterrupted shoulder on the scroll when the latter is bodily shifted toward the mouting shoulder to define a gas seal between the scroll and the engine block.

  2. Photovoltaic mounting/demounting unit

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to a photovoltaic arrangement comprising a photovoltaic assembly comprising a support structure defining a mounting surface onto which a photovoltaic module is detachably mounted; and a mounting/demounting unit comprising at least one mounting/demounting apparatus...... which when the mounting/demounting unit is moved along the mounting surface, causes the photovoltaic module to be mounted or demounted to the support structure; wherein the photovoltaic module comprises a carrier foil and wherein a total thickness of the photo voltaic module is below 500 muiotaeta....... The present invention further relates to an associated method for mounting/demounting photovoltaic modules....

  3. Housing And Mounting Structure

    Science.gov (United States)

    Anderson, Gene R.; Armendariz, Marcelino G.; Baca, Johnny R.F.; Bryan, Robert P.; Carson, Richard F.; Duckett, III, Edwin B.; McCormick, Frederick B.; Miller, Gregory V.; Peterson, David W.; Smith, Terrance T.

    2005-03-08

    This invention relates to an optical transmitter, receiver or transceiver module, and more particularly, to an apparatus for connecting a first optical connector to a second optical connector. The apparatus comprises: (1) a housing having at least a first end and at least a second end, the first end of the housing capable of receiving the first optical connector, and the second end of the housing capable of receiving the second optical connector; (2) a longitudinal cavity extending from the first end of the housing to the second end of the housing; and (3) an electromagnetic shield comprising at least a portion of the housing. This invention also relates to an apparatus for housing a flexible printed circuit board, and this apparatus comprises: (1) a mounting structure having at least a first surface and a second surface; (2) alignment ridges along the first and second surfaces of the mounting structure, the alignment ridges functioning to align and secure a flexible printed circuit board that is wrapped around and attached to the first and second surfaces of the mounting structure; and (3) a series of heat sink ridges adapted to the mounting structure, the heat sink ridges functioning to dissipate heat that is generated from the flexible printed circuit board.

  4. Transducer-Mounting Fixture

    Science.gov (United States)

    Spiegel, Kirk W.

    1990-01-01

    Transducer-mounting fixture holds transducer securely against stud. Projects only slightly beyond stud after installation. Flanged transducer fits into fixture when hinged halves open. When halves reclosed, fixture tightened onto threaded stud until stud makes contact with transducer. Knurled area on fixture aids in tightening fixture on stud.

  5. Characterization of Engine Mount Elastomers

    National Research Council Canada - National Science Library

    Szabo, Jeffrey P

    2005-01-01

    As part of a project to develop methods for modelling the performance of engine mounts, several oil resistant alternative materials were prepared, and compared to conventional materials from mounts...

  6. Modular reactor head shielding system

    International Nuclear Information System (INIS)

    Jacobson, E. B.

    1985-01-01

    An improved modular reactor head shielding system is provided that includes a frame which is removably assembled on a reactor head such that no structural or mechanical alteration of the head is required. The shielding system also includes hanging assemblies to mount flexible shielding pads on trolleys which can be moved along the frame. The assemblies allow individual pivoting movement of the pads. The pivoting movement along with the movement allowed by the trolleys provides ease of access to any point on the reactor head. The assemblies also facilitate safe and efficient mounting of the pads directly to and from storage containers such that workers have additional shielding throughout virtually the entire installation and removal process. The flexible shielding pads are designed to interleave with one another when assembled around the reactor head for substantially improved containment of radiation leakage

  7. Heads Up

    Science.gov (United States)

    ... Connect with Us HEADS UP Apps Reshaping the Culture Around Concussion in Sports Get HEADS UP on Your Web Site Concussion ... HEADS UP on your web site! Create a culture of safety for young athletes Officials, learn how you can ... UP to Providers HEADS UP to Youth Sports HEADS UP to School Sports HEADS UP to ...

  8. Resilient mounting systems in buildings

    NARCIS (Netherlands)

    Breeuwer, R.; Tukker, J.C.

    1976-01-01

    The basic elements of resilient mounting systems are described and various measures for quantifying the effect of such systems defined. Using electrical analogue circuits, the calculation of these measures is illustrated. With special reference to resilient mounting systems in buildings, under

  9. Mount Rainier National Park

    Science.gov (United States)

    Hoffman, Robert; Woodward, Andrea; Haggerty, Patricia K.; Jenkins, Kurt J.; Griffin, Paul C.; Adams, Michael J.; Hagar, Joan; Cummings, Tonnie; Duriscoe, Dan; Kopper, Karen; Riedel, Jon; Samora, Barbara; Marin, Lelaina; Mauger, Guillaume S.; Bumbaco, Karen; Littell, Jeremy S.

    2014-01-01

    Natural Resource Condition Assessments (NRCAs) evaluate current conditions for a subset of natural resources and resource indicators in national parks. NRCAs also report on trends in resource condition (when possible), identify critical data gaps, and characterize a general level of confidence for study findings. The resources and indicators emphasized in a given project depend on the park’s resource setting, status of resource stewardship planning and science in identifying high-priority indicators, and availability of data and expertise to assess current conditions for a variety of potential study resources and indicators. Although the primary objective of NRCAs is to report on current conditions relative to logical forms of reference conditions and values, NRCAs also report on trends, when appropriate (i.e., when the underlying data and methods support such reporting), as well as influences on resource conditions. These influences may include past activities or conditions that provide a helpful context for understanding current conditions and present-day threats and stressors that are best interpreted at park, watershed, or landscape scales (though NRCAs do not report on condition status for land areas and natural resources beyond park boundaries). Intensive cause-andeffect analyses of threats and stressors, and development of detailed treatment options, are outside the scope of NRCAs. It is also important to note that NRCAs do not address resources that lack sufficient data for assessment. For Mount Rainier National Park, this includes most invertebrate species and many other animal species that are subject to significant stressors from climate change and other anthropogenic sources such as air pollutants and recreational use. In addition, we did not include an analysis of the physical hydrology associated with streams (such as riverine landforms, erosion and aggradation which is significant in MORA streams), due to a loss of staff expertise from the USGS

  10. Detector Mount Design for IGRINS

    Directory of Open Access Journals (Sweden)

    Jae Sok Oh

    2014-06-01

    Full Text Available The Immersion Grating Infrared Spectrometer (IGRINS is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG Focal Plane Array (H2RG FPA detectors. We present the design and fabrication of the detector mount for the H2RG detector. The detector mount consists of a detector housing, an ASIC housing, a Field Flattener Lens (FFL mount, and a support base frame. The detector and the ASIC housing should be kept at 65 K and the support base frame at 130 K. Therefore they are thermally isolated by the support made of GFRP material. The detector mount is designed so that it has features of fine adjusting the position of the detector surface in the optical axis and of fine adjusting yaw and pitch angles in order to utilize as an optical system alignment compensator. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the structural and thermal analysis, the designed detector mount meets an optical stability tolerance and system thermal requirements. Actual detector mount fabricated based on the design has been installed into the IGRINS cryostat and successfully passed a vacuum test and a cold test.

  11. Reflections of Head Mounted systems for Domotic Control

    DEFF Research Database (Denmark)

    Mardanbeigi, Diako; Witzner Hansen, Dan

    2010-01-01

    In this report we would like to investigate the generalization of the concept of gaze interaction and investigate the possibility of using a gaze tracker for interaction not only with a single computer screen but also with multiple computer screens and possibly other environment objects in an int...

  12. Light Field Rendering for Head Mounted Displays using Pixel Reprojection

    DEFF Research Database (Denmark)

    Hansen, Anne Juhler; Klein, Jákup; Kraus, Martin

    2017-01-01

    of the information of the different images is redundant, we use pixel reprojection from the corner cameras to compute the remaining images in the light field. We compare the reprojected images with directly rendered images in a user test. In most cases, the users were unable to distinguish the images. In extreme...... cases, the reprojection approach is not capable of creating the light field. We conclude that pixel reprojection is a feasible method for rendering light fields as far as quality of perspective and diffuse shading is concerned, but render time needs to be reduced to make the method practical....

  13. Mount Oku, Cameroon Volcanic Line

    African Journals Online (AJOL)

    and continental sectors especially for trace elements in basalts. ... continental sector of the trend is a complex .... values higher than those of HIMU but is within ...... (Mount Cameroon, Central Africa): petrogenetic implications. Miner. Petrol.,.

  14. Solar panel parallel mounting configuration

    Science.gov (United States)

    Mutschler, Jr., Edward Charles (Inventor)

    1998-01-01

    A spacecraft includes a plurality of solar panels interconnected with a power coupler and an electrically operated device to provide power to the device when the solar cells are insolated. The solar panels are subject to bending distortion when entering or leaving eclipse. Spacecraft attitude disturbances are reduced by mounting each of the solar panels to an elongated boom made from a material with a low coefficient of thermal expansion, so that the bending of one panel is not communicated to the next. The boom may be insulated to reduce its bending during changes in insolation. A particularly advantageous embodiment mounts each panel to the boom with a single mounting, which may be a hinge. The single mounting prevents transfer of bending moments from the panel to the boom.

  15. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph

    2017-07-11

    A photovoltaic panel mounting clip comprising a base, central indexing tabs, flanges, lateral indexing tabs, and vertical indexing tabs. The mounting clip removably attaches one or more panels to a beam or the like structure, both mechanically and electrically. It provides secure locking of the panels in all directions, while providing guidance in all directions for accurate installation of the panels to the beam or the like structure.

  16. Solar panel truss mounting systems and methods

    Energy Technology Data Exchange (ETDEWEB)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2016-06-28

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  17. Solar panel truss mounting systems and methods

    Energy Technology Data Exchange (ETDEWEB)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2018-01-30

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  18. Solar panel truss mounting systems and methods

    Science.gov (United States)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2015-10-20

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  19. Femtogram-level detection of Clostridium botulinum neurotoxin type A by sandwich immunoassay using nanoporous substrate and ultra-bright fluorescent suprananoparticles.

    Science.gov (United States)

    Bok, Sangho; Korampally, Venumadhav; Darr, Charles M; Folk, William R; Polo-Parada, Luis; Gangopadhyay, Keshab; Gangopadhyay, Shubhra

    2013-03-15

    We report a simple, robust fluorescence biosensor for the ultra-sensitive detection of Clostridium botulinum Neurotoxin Type A (BoNT/A) in complex, real-world media. High intrinsic signal amplification was achieved through the combined use of ultra-bright, photostable dye-doped nanoparticle (DOSNP) tags and high surface area nanoporous organosilicate (NPO) thin films. DOSNP with 22 nm diameter were synthesized with more than 200 times equivalent free dye fluorescence and conjugated to antibodies with average degree of substitution of 90 dyes per antibody, representing an order of magnitude increase compared with conventional dye-labeled antibodies. The NPO films were engineered to form constructive interference at the surface where fluorophores were located. In addition, DOSNP-labeled antibodies with NPO films increased surface roughness causing diffuse scattering resulting in 24% more scattering intensity than dye-labeled antibody with NPO films. These substrates were used for immobilization of capture antibodies against BoNT/A, which was further quantified by DOSNP-labeled signal antibodies. The combination of optical effects enhanced the fluorescence and, therefore, the signal-to-noise ratio significantly. BoNT/A was detected in PBS buffer down to 21.3 fg mL(-1) in 4 h. The assay was then extended to several complex media and the four-hour detection limit was found to be 145.8 fg mL(-1) in orange juice and 164.2 fg mL(-1) in tap water, respectively, demonstrating at least two orders of magnitude improvement comparing to the reported detection limit of other enzyme-linked immunosorbent assays (ELISA). This assay, therefore, demonstrates a novel method for rapid, ultra-low level detection of not only BoNT/A, but other analytes as well. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Quantitative analysis of inclusions in high-strength steels by x-ray computed tomography using ultra-bright synchrotron radiation

    International Nuclear Information System (INIS)

    Shiozawa, Daiki; Nakai, Yoshikazu; Morikage, Yasushi; Tanaka, Hiroshi; Okado, Hideki; Miyashita, Takuya

    2006-01-01

    The observation of internal microstructures in materials is important to elucidate the mechanisms of ultra-long life fatigue of high-strength steels, and to ensure the integrity of structures. By conventional techniques, such as laboratory X-ray and ultrasonic imaging, the size and shape of subsurface non-metallic inclusions and cracks, those are smaller than 100 μm, cannot be measured. Then, in the present study, the ultra-bright synchrotron radiation X-ray was applied to the imaging of subsurface inclusion. To obtain basic data for the measurement, the penetration depth of synchrotron radiation wave in a free-cutting steel was examined. It was found that the depths where the transmitted wave cannot be observed are 100 μm for 15 keV, 200 μm for 20 keV, 600 μm for 25 keV, and 800 μm for 30 keV. For the measurement of size and shape of inclusion, synchrotron radiation computed tomography method (SR-CT) was employed. Metallographic structures can be observed in a free-cutting steel, and the diameter of these structures is about 7 - 10 μm. They are considered to be inclusions, which mainly contain manganese sulfide (MnS) or pearlitic phase. To investigate the possibility of detection of pearlitic phase, SR-CT was applied to observe the metallographic structures in carbon steel (S35C), which contains a lot of pearlitic phase and a little inclusion. In this case, no metallographic structure was observed inside specimen. These results indicate that the microstructures those were observed by SR-CT method was inclusions, not pearlitic phase. (author)

  1. Virtual sine arm kinematic mount system

    International Nuclear Information System (INIS)

    Xu, Z.; Randall, K.J.

    1997-01-01

    A novel kinematic mount system for a vertical focusing mirror of the soft x-ray spectroscopy beamline at the Advanced Photon Source is described. The system contains three points in a horizontal plane. Each point consists of two horizontal linear precision stages, a spherical ball bearing, and a vertical precision stage. The horizontal linear stages are aligned orthogonally and are conjoined by a spherical ball bearing, supported by the vertical linear stage at each point. The position of each confined horizontal stage is controlled by a motorized micrometer head by spring-loading the flat tip of the micrometer head onto a tooling ball fixing on the carriage of the stage. A virtual sine arm is formed by tilting the upstream horizontal stage down and the two downstream horizontal stages up by a small angle. The fine pitch motion is achieved by adjusting the upstream stage. This supporting structure is extremely steady due to a relatively large span across the supporting points and yields extremely high resolution on the pitch motion. With a one degree tilt and a microstepping motor, the authors achieved a 0.4 nanoradian resolution on the mirror pitch motion

  2. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph; Valdes, Francisco

    2017-02-14

    An exemplary mounting clip for removably attaching panels to a supporting structure comprises a base, spring locking clips, a lateral flange, a lever flange, and a spring bonding pad. The spring locking clips extend upwardly from the base. The lateral flange extends upwardly from a first side of the base. The lateral flange comprises a slot having an opening configured to receive at least a portion of one of the one or more panels. The lever flange extends outwardly from the lateral flange. The spring bonding flange extends downwardly from the lever flange. At least a portion of the first spring bonding flange comprises a serrated edge for gouging at least a portion of the one or more panels when the one or more panels are attached to the mounting clip to electrically and mechanically couple the one or more panels to the mounting clip.

  3. Mounting power cables on SOLEIL

    CERN Multimedia

    Laurent Guiraud

    1999-01-01

    The power couplers are mounted on the SOLEIL cryomodule in a clean room. The cryomodule will allow superconducting technology to be used at SOLEIL, the French national synchrotron facility. This work is carried out as part of a collaboration between CERN and CEA Saclay, the French National Atomic Energy Commission.

  4. Shock Mounting for Heavy Machines

    Science.gov (United States)

    Thompson, A. R.

    1984-01-01

    Elastomeric bearings eliminate extraneous forces. Rocket thrust transmitted from motor to load cells via support that absorbs extraneous forces so they do not affect accuracy of thrust measurements. Adapter spoked cone fits over forward end of rocket motor. Shock mounting developed for rocket engines under test used as support for heavy machines, bridges, or towers.

  5. Mount St. Helens aerosol evolution

    Energy Technology Data Exchange (ETDEWEB)

    Oberbeck, V.R.; Farlow, N.H.

    1982-08-01

    Stratospheric aerosol samples were collected using a wire impactor during the year following the eruption of Mount St. Helens. Analysis of samples shows that aerosol volume increased for 6 months due to gas-to-particle conversion and then decreased to background levels in the following 6 months.

  6. Control of Wall Mounting Robot

    DEFF Research Database (Denmark)

    Sloth, Christoffer; Pedersen, Rasmus

    2017-01-01

    This paper presents a method for designing controllers for trajectory tracking with actuator constraints. In particular, we consider a joystick-controlled wall mounting robot called WallMo. In contrast to previous works, a model-free approach is taken to the control problem, where the path...

  7. Head of detector for multi-element analysis

    International Nuclear Information System (INIS)

    Frynta, Z.

    1983-01-01

    The detector head mounted on the scintillation counter consists of a hollow hexagonal rotary support axially arranged with the photomultiplier of the scintillation counter. In the walls of the hexagonal rotary support there are openings in which are inserted absorption filters. The mounting of the absorption filters on the rotary support allows the analysis of a greater number of elements without the dismantling of the head and the replacement of filters. The suitable geometry of the head is retained so that it is possible to insert the head into the hollows similarly as the scintillation counter. (J.P.)

  8. Using wintergreen oil for mounting mosquito larvae: a safer alternative to xylene.

    Science.gov (United States)

    Koay, J B; Natasya, N N; Nashithatul, Mag; Ihsanuddin, R; Salleh, F M; Azil, A H

    2016-01-01

    Permanent mounting of fourth instar mosquito larvae is essential for identifying Aedes spp. This procedure requires extensive exposure to xylene, a clearing agent in the mounting process. We investigated wintergreen oil as a substitute for xylene. Five hundred larvae were mounted on slides to evaluate shrinkage or expansion of specimens after clearing using xylene or wintergreen oil. We examined the ventral brush and siphonal hair tufts for species identification and for preservation of morphological characteristics after clearing specimens in xylene or wintergreen oil. Shrinkage of the length of whole larvae and width of the head, thorax and abdomen after mounting was significantly greater after clearing with xylene than with wintergreen oil. The length of the comb scale nearest the ventral brush was similar for both clearing agents. The clarity of the specimens after mounting was improved by clearing with wintergreen oil, but the integrity of the ventral brush and siphonal hair tufts were similar for both clearing agents.

  9. Tension pneumocephalus: Mount Fuji sign

    Directory of Open Access Journals (Sweden)

    Pulastya Sanyal

    2015-01-01

    Full Text Available A 13-year-old male was operated for a space occupying lesion in the brain. A noncontrast computed tomography scan done in the late postoperative period showed massive subdural air collection causing compression of bilateral frontal lobes with widening of interhemispheric fissure and the frontal lobes acquiring a peak like configuration - causing tension pneumocephalus-"Mount Fuji sign." Tension pneumocephalus occurs when air enters the extradural or intradural spaces in sufficient volume to exert a mass or pressure effect on the brain, leading to brain herniation. Tension pneumocephalus is a surgical emergency, which needs immediate intervention in the form of decompression of the cranial cavity by a burr hole or needle aspiration. The Mount Fuji sign differentiates tension pneumocephalus from pneumocephalus.

  10. Mounting support for a photovoltaic module

    Science.gov (United States)

    Brandt, Gregory Michael; Barsun, Stephan K.; Coleman, Nathaniel T.; Zhou, Yin

    2013-03-26

    A mounting support for a photovoltaic module is described. The mounting support includes a foundation having an integrated wire-way ledge portion. A photovoltaic module support mechanism is coupled with the foundation.

  11. Flush Mounting Of Thin-Film Sensors

    Science.gov (United States)

    Moore, Thomas C., Sr.

    1992-01-01

    Technique developed for mounting thin-film sensors flush with surfaces like aerodynamic surfaces of aircraft, which often have compound curvatures. Sensor mounted in recess by use of vacuum pad and materials selected for specific application. Technique involves use of materials tailored to thermal properties of substrate in which sensor mounted. Together with customized materials, enables flush mounting of thin-film sensors in most situations in which recesses for sensors provided. Useful in both aircraft and automotive industries.

  12. Tourism-Related Impacts on Mount Kilimanjaro, Tanzania: Implications for Tourism Management on Mountain Ecosystems

    OpenAIRE

    James WAKIBARA; Kimaro NDESARI; Nyamakumbati MAFURU

    2009-01-01

    Waste disposal, trail erosion, water contamination and porter head loads were investigated on Mount Kilimanjaro, Tanzania, from 2003-2005. Generated waste was identified and quantified, trail erosion measured, water sources examined for colifom contamination and head loads for Porters re-weighed against official limits. Waste on trails comprised mainly of fluffy items. Trail erosion was directly related to hiking pressure whereas water was contaminated mainly at lower elevation. Porters remov...

  13. Mounting Thin Samples For Electrical Measurements

    Science.gov (United States)

    Matus, L. G.; Summers, R. L.

    1988-01-01

    New method for mounting thin sample for electrical measurements involves use of vacuum chuck to hold a ceramic mounting plate, which holds sample. Contacts on mounting plate establish electrical connection to sample. Used to make electrical measurements over temperature range from 77 to 1,000 K and does not introduce distortions into magnetic field during Hall measurements.

  14. Head Lice

    Science.gov (United States)

    ... nits. You should also use hot water to wash any bed linens, towels, and clothing recently worn by the person who had head lice. Vacuum anything that can’t be washed, such as the couch, carpets, your child’s car seat, and any stuffed animals. Because head lice ...

  15. Apparent Brecciation Gradient, Mount Desert Island, Maine

    Science.gov (United States)

    Hawkins, A. T.; Johnson, S. E.

    2004-05-01

    Mount Desert Island, Maine, comprises a shallow level, Siluro-Devonian igneous complex surrounded by a distinctive breccia zone ("shatter zone" of Gilman and Chapman, 1988). The zone is very well exposed on the southern and eastern shores of the island and provides a unique opportunity to examine subvolcanic processes. The breccia of the Shatter Zone shows wide variation in percent matrix and clast, and may represent a spatial and temporal gradient in breccia formation due to a single eruptive or other catastrophic volcanic event. The shatter zone was divided into five developmental stages based on the extent of brecciation: Bar Harbor Formation, Sols Cliffs breccia, Seeley Road breccia, Dubois breccia, and Great Head breccia. A digital camera was employed to capture scale images of representative outcrops using a 0.5 m square Plexiglas frame. Individual images were joined in Adobe Photoshop to create a composite image of each outcrop. The composite photo was then exported to Adobe Illustrator, which was used to outline the clasts and produce a digital map of the outcrop for analysis. The fractal dimension (Fd) of each clast was calculated using NIH Image and a Euclidean distance mapping method described by Bérubé and Jébrak (1999) to quantify the morphology of the fragments, or the complexity of the outline. The more complex the fragment outline, the higher the fractal dimension, indicating that the fragment is less "mature" or has had less exposure to erosional processes, such as the injection of an igneous matrix. Sols Cliffs breccia has an average Fd of 1.125, whereas Great Head breccia has an average Fd of 1.040, with the stages between having intermediate values. The more complex clasts of the Sols Cliffs breccia with a small amount (26.38%) of matrix material suggests that it is the first stage in a sequence of brecciation ending at the more mature, matrix-supported (71.37%) breccia of Great Head. The results of this study will be used to guide isotopic

  16. Driving with head-slaved camera system

    NARCIS (Netherlands)

    Oving, A.B.; Erp, J.B.F. van

    2001-01-01

    In a field experiment, we tested the effectiveness of a head-slaved camera system for driving an armoured vehicle under armour. This system consists of a helmet-mounted display (HMD), a headtracker, and a motion platform with two cameras. Subjects performed several driving tasks on paved and in

  17. Head Injuries

    Science.gov (United States)

    ... a severe blow to the head can still knock the brain into the side of the skull ... following certain precautions and taking a break from sports and other activities that make symptoms worse. Playing ...

  18. Ocean floor mounting of wave energy converters

    Science.gov (United States)

    Siegel, Stefan G

    2015-01-20

    A system for mounting a set of wave energy converters in the ocean includes a pole attached to a floor of an ocean and a slider mounted on the pole in a manner that permits the slider to move vertically along the pole and rotate about the pole. The wave energy converters can then be mounted on the slider to allow adjustment of the depth and orientation of the wave energy converters.

  19. Mounting and Alignment of IXO Mirror Segments

    Science.gov (United States)

    Chan, Kai-Wing; Zhang, William; Evans, Tyler; McClelland, Ryan; Hong, Melinda; Mazzarella, James; Saha, Timo; Jalota, Lalit; Olsen, Lawrence; Byron, Glenn

    2010-01-01

    A suspension-mounting scheme is developed for the IXO (International X-ray Observatory) mirror segments in which the figure of the mirror segment is preserved in each stage of mounting. The mirror, first fixed on a thermally compatible strongback, is subsequently transported, aligned and transferred onto its mirror housing. In this paper, we shall outline the requirement, approaches, and recent progress of the suspension mount processes.

  20. Head orientation prediction: delta quaternions versus quaternions.

    Science.gov (United States)

    Himberg, Henry; Motai, Yuichi

    2009-12-01

    Display lag in simulation environments with helmet-mounted displays causes a loss of immersion that degrades the value of virtual/augmented reality training simulators. Simulators use predictive tracking to compensate for display lag, preparing display updates based on the anticipated head motion. This paper proposes a new method for predicting head orientation using a delta quaternion (DQ)-based extended Kalman filter (EKF) and compares the performance to a quaternion EKF. The proposed framework operates on the change in quaternion between consecutive data frames (the DQ), which avoids the heavy computational burden of the quaternion motion equation. Head velocity is estimated from the DQ by an EKF and then used to predict future head orientation. We have tested the new framework with captured head motion data and compared it with the computationally expensive quaternion filter. Experimental results indicate that the proposed DQ method provides the accuracy of the quaternion method without the heavy computational burden.

  1. Channel uranium-graphite reactor mounting

    International Nuclear Information System (INIS)

    Polushkin, K.K.; Kuznetsov, A.G.; Zheleznyakov, B.N.

    1981-01-01

    According to theoretical principles of general engineering technology the engineering experience of construction-mounting works at the NPP with channel uranium-graphite reactors is systematized. Main parameters and structural features of the 1000 MW channel uranium-graphite reactors are considered. The succession of mounting operations, premounting equipment and pipelines preparation and mounting works technique are described. The most efficient methods of fitting, welding and machining of reactor elements are recommended. Main problems of technical control service are discussed. A typical netted diagram of main equipment of channel uranium-graphite reactors mounting is given

  2. 49 CFR 179.10 - Tank mounting.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Tank mounting. 179.10 Section 179.10 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Design Requirements § 179.10 Tank mounting. (a) The manner in which tanks are attached to the car...

  3. Low-Thermal-Resistance Baseplate Mounting

    Science.gov (United States)

    Perreault, W. T.

    1984-01-01

    Low-thermal-resistance mounting achieved by preloading baseplate to slight convexity with screws threaded through beam. As mounting bolts around edge of base-place tightened, baseplate and cold plate contact first in center, with region of intimate contact spreading outward as bolts tightened.

  4. Mount Athos: Between autonomy and statehood

    Directory of Open Access Journals (Sweden)

    Avramović Dragutin

    2013-01-01

    Full Text Available Legal status of the Mount Athos is characterized by many special features that make it internationally unique legal regime. The author analyzes peculiarities of Mount Athos territorial status, legal position of residents and visitors, as well as organization of Mount Athos authorities. The author concludes that the Mount Athos is characterized by a kind of para-sovereignty. Its autonomy involves not only the internal organization, autonomous governance and religious autonomy, but it also includes many elements of secular life of their visitors. Mount Athos has its own, separate legislative, administrative and judicial powers, while the Statute of the Mount Athos has greater legal force than all the other laws of the Greek state, because the state can not unilaterally change its provisions. Having in mind that the wide self-government is vested in church authorities and that the monks have very specific way of living, the author takes a position that the Mount Athos represent 'monastic state', but without statehood. The author also states that the Mount Athos will be faced with many challenges in the context of spreading of an assimilating, universal conception of human rights.

  5. Head Start.

    Science.gov (United States)

    Greenman, Geri

    2000-01-01

    Discusses an art project in which students created drawings of mop heads. Explains that the approach of drawing was more important than the subject. States that the students used the chiaroscuro technique, used by Rembrandt and Caravaggio, in which light appears out of the darkness. (CMK)

  6. Drill cuttings mount formation study

    Science.gov (United States)

    Teh, Su Yean; Koh, Hock Lye

    2014-07-01

    Oil, Gas and Energy sector has been identified as an essential driving force in the Malaysian Economic Transformation Programs (ETP). Recently confirmed discovery of many offshore oil and gas deposits in Malaysian waters has ignited new confidence in this sector. However, this has also spurred intense interest on safeguarding the health and environment of coastal waters in Malaysia from adverse impact resulting from offshore oil and gas production operation. Offshore discharge of spent drilling mud and rock cuttings is the least expensive and simplest option to dispose of large volumes of drilling wastes. But this onsite offshore disposal may have adverse environmental impacts on the water column and the seabed. It may also pose occupational health hazards to the workers living in the offshore platforms. It is therefore important to model the transport and deposition of drilling mud and rock cuttings in the sea to enable proper assessment of their adverse impacts on the environment and the workers. Further, accumulation of drill particles on the seabed may impede proper operation of pipelines on the seabed. In this paper, we present an in-house application model TUNA-PT developed to cater to local oil and gas industry needs to simulate the dispersion and mount formation of drill cuttings by offshore oil and gas exploration and production platforms. Using available data on Malaysian coastal waters, simulation analyses project a pile formation on the seabed with a maximum height of about 1 m and pile radius of around 30 to 50 m. Simulated pile heights are not sensitive to the heights of release of the cuttings as the sensitivity has been mitigated by the depth of water.

  7. A Versatile Mounting Method for Long Term Imaging of Zebrafish Development.

    Science.gov (United States)

    Hirsinger, Estelle; Steventon, Ben

    2017-01-26

    Zebrafish embryos offer an ideal experimental system to study complex morphogenetic processes due to their ease of accessibility and optical transparency. In particular, posterior body elongation is an essential process in embryonic development by which multiple tissue deformations act together to direct the formation of a large part of the body axis. In order to observe this process by long-term time-lapse imaging it is necessary to utilize a mounting technique that allows sufficient support to maintain samples in the correct orientation during transfer to the microscope and acquisition. In addition, the mounting must also provide sufficient freedom of movement for the outgrowth of the posterior body region without affecting its normal development. Finally, there must be a certain degree in versatility of the mounting method to allow imaging on diverse imaging set-ups. Here, we present a mounting technique for imaging the development of posterior body elongation in the zebrafish D. rerio. This technique involves mounting embryos such that the head and yolk sac regions are almost entirely included in agarose, while leaving out the posterior body region to elongate and develop normally. We will show how this can be adapted for upright, inverted and vertical light-sheet microscopy set-ups. While this protocol focuses on mounting embryos for imaging for the posterior body, it could easily be adapted for the live imaging of multiple aspects of zebrafish development.

  8. An improved loopless mounting method for cryocrystallography

    International Nuclear Information System (INIS)

    Jian-Xun, Qi; Fan, Jiang

    2010-01-01

    Based on a recent loopless mounting method, a simplified loopless and bufferless crystal mounting method is developed for macromolecular crystallography. This simplified crystal mounting system is composed of the following components: a home-made glass capillary, a brass seat for holding the glass capillary, a flow regulator, and a vacuum pump for evacuation. Compared with the currently prevalent loop mounting method, this simplified method has almost the same mounting procedure and thus is compatible with the current automated crystal mounting system. The advantages of this method include higher signal-to-noise ratio, more accurate measurement, more rapid flash cooling, less x-ray absorption and thus less radiation damage to the crystal. This method can be extended to the flash-freeing of a crystal without or with soaking it in a lower concentration of cryoprotectant, thus it may be the best option for data collection in the absence of suitable cryoprotectant. Therefore, it is suggested that this mounting method should be further improved and extensively applied to cryocrystallographic experiments. (general)

  9. An improved loopless mounting method for cryocrystallography

    Science.gov (United States)

    Qi, Jian-Xun; Jiang, Fan

    2010-01-01

    Based on a recent loopless mounting method, a simplified loopless and bufferless crystal mounting method is developed for macromolecular crystallography. This simplified crystal mounting system is composed of the following components: a home-made glass capillary, a brass seat for holding the glass capillary, a flow regulator, and a vacuum pump for evacuation. Compared with the currently prevalent loop mounting method, this simplified method has almost the same mounting procedure and thus is compatible with the current automated crystal mounting system. The advantages of this method include higher signal-to-noise ratio, more accurate measurement, more rapid flash cooling, less x-ray absorption and thus less radiation damage to the crystal. This method can be extended to the flash-freeing of a crystal without or with soaking it in a lower concentration of cryoprotectant, thus it may be the best option for data collection in the absence of suitable cryoprotectant. Therefore, it is suggested that this mounting method should be further improved and extensively applied to cryocrystallographic experiments.

  10. Flow distortion on boom mounted cup anemometers

    DEFF Research Database (Denmark)

    Lindelöw, Per Jonas Petter; Friis Pedersen, Troels; Gottschall, Julia

    In this report we investigate on wind direction dependent errors in the measurement of the horizontal wind speed by boom mounted cup anemometers. The boom mounting on the studied lattice tower is performed according to IEC standard design rules, yet, larger deviations than predicted by flow models...... are observed. The errors on the measurements are likely caused by an underestimation of the flow distortions around the tower. In this paper an experimental method for deriving a correction formula and an in-field calibration is suggested. The method is based on measurements with two cup anemometers mounted...

  11. A Portable Shoulder-Mounted Camera System for Surgical Education in Spine Surgery.

    Science.gov (United States)

    Pham, Martin H; Ohiorhenuan, Ifije E; Patel, Neil N; Jakoi, Andre M; Hsieh, Patrick C; Acosta, Frank L; Wang, Jeffrey C; Liu, John C

    2017-02-07

    The past several years have demonstrated an increased recognition of operative videos as an important adjunct for resident education. Currently lacking, however, are effective methods to record video for the purposes of illustrating the techniques of minimally invasive (MIS) and complex spine surgery. We describe here our experiences developing and using a shoulder-mounted camera system for recording surgical video. Our requirements for an effective camera system included wireless portability to allow for movement around the operating room, camera mount location for comfort and loupes/headlight usage, battery life for long operative days, and sterile control of on/off recording. With this in mind, we created a shoulder-mounted camera system utilizing a GoPro™ HERO3+, its Smart Remote (GoPro, Inc., San Mateo, California), a high-capacity external battery pack, and a commercially available shoulder-mount harness. This shoulder-mounted system was more comfortable to wear for long periods of time in comparison to existing head-mounted and loupe-mounted systems. Without requiring any wired connections, the surgeon was free to move around the room as needed. Over the past several years, we have recorded numerous MIS and complex spine surgeries for the purposes of surgical video creation for resident education. Surgical videos serve as a platform to distribute important operative nuances in rich multimedia. Effective and practical camera system setups are needed to encourage the continued creation of videos to illustrate the surgical maneuvers in minimally invasive and complex spinal surgery. We describe here a novel portable shoulder-mounted camera system setup specifically designed to be worn and used for long periods of time in the operating room.

  12. Post Traumatic Tension Pneumocephalus: The Mount Fuji Sign

    LENUS (Irish Health Repository)

    Ryan, J

    2017-04-01

    Pneumocephalus is defined as the presence of intracranial air. This is most commonly secondary to a traumatic head injury. Tension pneumocephalus presents radiologically with compression of the frontal lobes and widening of the interhemispheric space between the frontal lobes. It is often termed the Mount Fuji sign due to a perceived similarity with an iconic mountain peak in Japan. We present the case of a 52-year-old gentleman who presented to the emergency department shortly before 8am on a Saturday morning following an assault. He was alert and ambulatory with no clinical evidence of raised intracranial pressure. A plain radiograph of the facial bones showed significant pneumocephalus. A later CT was consistent with a tension pneumocephalus which usually necessitates urgent decompression.The patient showed no clinical signs or symptoms of raised intracranial pressure and was managed conservatively. He was discharged home 16 days later with no neurological deficit

  13. Biodiversity of the flora of Mount Papa

    International Nuclear Information System (INIS)

    Yin-Yin-Kyi

    1995-07-01

    Even though Mount Papa is in the dry zone area, it is almost evergreen, due to its elevation of 4981 feet above the sea level and its fertile soil conditions. A has a rich biodiversity with vegetation of many types

  14. May 1980 Mount Saint Helens, USA Images

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — An earthquake occurred at 15 32 UT, only seconds before the explosion that began the eruption of Mount St. Helens volcano. This eruption and blast blew off the top...

  15. Photoelectric panel with equatorial mounting of drive

    Science.gov (United States)

    Kukhta, M. S.; Krauinsh, P. Y.; Krauinsh, D. P.; Sokolov, A. P.; Mainy, S. B.

    2018-03-01

    The relevance of the work is determined by the need to create effective models for sunny energy. The article considers a photoelectric panel equipped with a system for tracking the sun. Efficiency of the system is provided by equatorial mounting, which compensates for the rotation of the Earth by rotating the sunny panel in the plane of the celestial equator. The specificity of climatic and geographical conditions of Tomsk is estimated. The dynamics of power variations of photoelectric panels with equatorial mounting during seasonal fluctuations in Tomsk is calculated. A mobile photovoltaic panel with equatorial mounting of the drive has been developed. The methods of design strategy for placing photovoltaic panels in the architectural environment of the city are presented. Key words: sunny energy, photovoltaics, equatorial mounting, mechatronic model, wave reducer, electric drive.

  16. Flued head replacement alternatives

    International Nuclear Information System (INIS)

    Smetters, J.L.

    1987-01-01

    This paper discusses flued head replacement options. Section 2 discusses complete flued head replacement with a design that eliminates the inaccessible welds. Section 3 discusses alternate flued head support designs that can drastically reduce flued head installation costs. Section 4 describes partial flued head replacement designs. Finally, Section 5 discusses flued head analysis methods. (orig./GL)

  17. Isolation Mounting for Charge-Coupled Devices

    Science.gov (United States)

    Goss, W. C.; Salomon, P. M.

    1985-01-01

    CCD's suspended by wires under tension. Remote thermoelectric cooling of charge coupled device allows vibration isolating mounting of CCD assembly alone, without having to suspend entire mass and bulk of thermoelectric module. Mounting hardware simple and light. Developed for charge-coupled devices (CCD's) in infrared telescope support adaptable to sensors in variety of environments, e.g., sensors in nuclear reactors, engine exhausts and plasma chambers.

  18. Goniometer head

    International Nuclear Information System (INIS)

    Dzhazairov-Kakhramanov, V.; Berger, V.D.; Kadyrzhanov, K.K.; Zarifov, R.A.

    1994-01-01

    The goniometer head is an electromechanical instrument that performs the independent transfer of a testing sample on three coordinate axes (X, Y, Z) within limits of ±8 mm and independent rotation relative of these directions. The instrument comprises a sample holder, bellows component and three electrometer drives. The sample holder rotates around the axes X and Y, and is installed on the central arm which rotates around axis Z. One characteristic of this instrument is its independence which allows its use in any camera for researches in the field of radiation physics. 2 figs

  19. "Split Cast Mounting: Review and New Technique".

    Science.gov (United States)

    Gundawar, S M; Pande, Neelam A; Jaiswal, Priti; Radke, U M

    2014-12-01

    For the fabrication of a prosthesis, the Prosthodontist meticulously performs all the steps. The laboratory technician then make every effort/strives to perform the remaining lab procedures. However when the processed dentures are remounted on the articulator, some changes are seen. These changes may be divided into two categories: Pre-insertion and post-insertion changes, which deal with the physical properties of the materials involved (Parker, J Prosthet Dent 31:335-342, 1974). Split cast mounting is the method of mounting casts on the articulator. It is essentially a maxillary cast constructed in two parts with a horizontal division. The procedure allows for the verification of the accuracy of the initial mounting and the ease of removal and replacement of the cast. This provides a precise means of correcting the changes in occlusion occurring as a result of the processing technique (Nogueira et al., J Prosthet Dent 91:386-388, 2004). Instability of the split mounting has always been a problem to the Prosthodontist thereby limiting its use. There are various materials mentioned in the literature. The new technique by using Dowel pins and twill thread is very easy, cheaper and simple way to stabilize the split mounting. It is useful and easy in day to day laboratory procedures. The article presents different methods of split cast mounting and the new procedure using easily available materials in prosthetic laboratory.

  20. Analysis of adjusting effects of mounting force on frequency conversion of mounted nonlinear optics.

    Science.gov (United States)

    Su, Ruifeng; Liu, Haitao; Liang, Yingchun; Lu, Lihua

    2014-01-10

    Motivated by the need to increase the second harmonic generation (SHG) efficiency of nonlinear optics with large apertures, a novel mounting configuration with active adjusting function on the SHG efficiency is proposed and mechanically and optically studied. The adjusting effects of the mounting force on the distortion and stress are analyzed by the finite element methods (FEM), as well as the contribution of the distortion and stress to the change in phase mismatch, and the SHG efficiency are theoretically stated. Further on, the SHG efficiency is calculated as a function of the mounting force. The changing trends of the distortion, stress, and the SHG efficiency with the varying mounting force are obtained, and the optimal ones are figured out. Moreover, the mechanism of the occurrence of the optimal values is studied and the adjusting strategy is put forward. Numerical results show the robust adjustment of the mounting force, as well as the effectiveness of the mounting configuration, in increasing the SHG efficiency.

  1. Technical preparation of the Yuzhteploehnergomontazh trust for technological equipment mounting

    International Nuclear Information System (INIS)

    Zayats, A.I.

    1982-01-01

    Measures of technical preparation for equipment mounting at the Zaporozhe NPP developed with the Yuzhteploehnergomontazh trust experts are considered. These measures envisage the construction of mounting base of heat facilities, calculation of labour contents and determination of necessary quantity of mounters, development of optimal flowsheet of mounting control, improvement of mounting qualification and creation of stable collective body, improvement of technical level of mounting and welding works, organizational-technical measures on mounting logistics. Factors affecting negatively technical preparation quality of equipment mounting at the Zaporozhe NPP are discussed. The flowsheet of mounting control is presented

  2. Field-trip guide to Mount Hood, Oregon, highlighting eruptive history and hazards

    Science.gov (United States)

    Scott, William E.; Gardner, Cynthia A.

    2017-06-22

    This guidebook describes stops of interest for a geological field trip around Mount Hood volcano. It was developed for the 2017 International Association of Volcanology and Chemistry of the Earth’s Interior (IAVCEI) Scientific Assembly in Portland, Oregon. The intent of this guidebook and accompanying contributions is to provide an overview of Mount Hood, including its chief geologic processes, magmatic system, eruptive history, local tectonics, and hazards, by visiting a variety of readily accessible localities. We also describe coeval, largely monogenetic, volcanoes in the region. Accompanying the field-trip guidebook are separately authored contributions that discuss in detail the Mount Hood magmatic system and its products and behavior (Kent and Koleszar, this volume); Mount Hood earthquakes and their relation to regional tectonics and the volcanic system (Thelen and Moran, this volume); and young surface faults cutting the broader Mount Hood area whose extent has come to light after acquisition of regional light detection and ranging coverage (Madin and others, this volume).The trip makes an approximately 175-mile (280-kilometer) clockwise loop around Mount Hood, starting and ending in Portland. The route heads east on Interstate 84 through the Columbia River Gorge National Scenic Area. The guidebook points out only a few conspicuous features of note in the gorge, but many other guides to the gorge are available. The route continues south on the Mount Hood National Scenic Byway on Oregon Route 35 following Hood River, and returns to Portland on U.S. Highway 26 following Sandy River. The route traverses rocks as old as the early Miocene Eagle Creek Formation and overlying Columbia River Basalt Group of middle Miocene age, but chiefly lava flows and clastic products of arc volcanism of late Miocene to Holocene age.

  3. 76 FR 76689 - Cibola National Forest, Mount Taylor Ranger District, NM, Mount Taylor Combined Exploratory Drilling

    Science.gov (United States)

    2011-12-08

    ... National Forest, Mount Taylor Ranger District, NM, Mount Taylor Combined Exploratory Drilling AGENCY... proposed action is to approve two Plans of Operations for exploratory uranium drilling on the Cibola... San Mateo. In total, there are up to 279 drill holes that would be drilled over a period not to exceed...

  4. Ball mounting fixture for a roundness gage

    Science.gov (United States)

    Gauler, Allen L.; Pasieka, Donald F.

    1983-01-01

    A ball mounting fixture for a roundness gage is disclosed. The fixture includes a pair of chuck assemblies oriented substantially transversely with respect to one another and mounted on a common base. Each chuck assembly preferably includes a rotary stage and a wobble plate affixed thereto. A ball chuck affixed to each wobble plate is operable to selectively support a ball to be measured for roundness, with the wobble plate permitting the ball chuck to be tilted to center the ball on the axis of rotation of the rotary stage. In a preferred embodiment, each chuck assembly includes a vacuum chuck operable to selectively support the ball to be measured for roundness. The mounting fixture enables a series of roundness measurements to be taken with a conventional rotating gagehead roundness instrument, which measurements can be utilized to determine the sphericity of the ball.

  5. Mounting system for optical frequency reference cavities

    Science.gov (United States)

    Notcutt, Mark (Inventor); Hall, John L. (Inventor); Ma, Long-Sheng (Inventor)

    2008-01-01

    A technique for reducing the vibration sensitivity of laser-stabilizing optical reference cavities is based upon an improved design and mounting method for the cavity, wherein the cavity is mounted vertically. It is suspended at one plane, around the spacer cylinder, equidistant from the mirror ends of the cavity. The suspension element is a collar of an extremely low thermal expansion coefficient material, which surrounds the spacer cylinder and contacts it uniformly. Once the collar has been properly located, it is cemented in place so that the spacer cylinder is uniformly supported and does not have to be squeezed at all. The collar also includes a number of cavities partially bored into its lower flat surface, around the axial bore. These cavities are support points, into which mounting base pins will be inserted. Hence the collar is supported at a minimum of three points.

  6. Analysis of linear head accelerations from collegiate football impacts.

    Science.gov (United States)

    Brolinson, P Gunnar; Manoogian, Sarah; McNeely, David; Goforth, Mike; Greenwald, Richard; Duma, Stefan

    2006-02-01

    Sports-related concussions result in 300,000 brain injuries in the United States each year. We conducted a study utilizing an in-helmet system that measures and records linear head accelerations to analyze head impacts in collegiate football. The Head Impact Telemetry (HIT) System is an in-helmet system with six spring-mounted accelerometers and an antenna that transmits data via radio frequency to a sideline receiver and laptop computer system. A total of 11,604 head impacts were recorded from the Virginia Tech football team throughout the 2003 and 2004 football seasons during 22 games and 62 practices from a total of 52 players. Although the incidence of injury data are limited, this study presents an extremely large data set from human head impacts that provides valuable insight into the lower limits of head acceleration that cause mild traumatic brain injuries.

  7. 14 CFR 33.23 - Engine mounting attachments and structure.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine mounting attachments and structure... mounting attachments and structure. (a) The maximum allowable limit and ultimate loads for engine mounting attachments and related engine structure must be specified. (b) The engine mounting attachments and related...

  8. Is HEADS in our heads?

    DEFF Research Database (Denmark)

    Boisen, Kirsten A; Hertz, Pernille Grarup; Blix, Charlotte

    2016-01-01

    contraception], Safety, Self-harm) interview is a feasible way of exploring health risk behaviors and resilience. OBJECTIVE: The purpose of this study was to evaluate how often HEADS topics were addressed according to young patients and staff in pediatric and adult outpatient clinics. METHODS: We conducted...... care professionals participated. We found only small reported differences between staff and young patients regarding whether home, education, and activity were addressed. However, staff reported twice the rate of addressing smoking, alcohol, illegal drugs, sexuality, and contraception compared to young...... patients. Young patients reported that smoking, alcohol, illegal drugs, sexuality, and contraception were addressed significantly more at adult clinics in comparison to pediatric clinics. After controlling for age, gender and duration of illness, according to young patients, adjusted odds ratios...

  9. BIOMECHANICS OF HEAD INJURY IN OLYMPIC TAEKWONDO AND BOXING

    Science.gov (United States)

    Fife, G.P.; Pieter, W.

    2013-01-01

    Objective The purpose was to examine differences between taekwondo kicks and boxing punches in resultant linear head acceleration (RLA), head injury criterion (HIC15), peak head velocity, and peak foot and fist velocities. Data from two existing publications on boxing punches and taekwondo kicks were compared. Methods For taekwondo head impacts a Hybrid II Crash Dummy (Hybrid II) head was instrumented with a tri-axial accelerometer mounted inside the Hybrid II head. The Hybrid II was fixed to a height-adjustable frame and fitted with a protective taekwondo helmet. For boxing testing, a Hybrid III Crash Dummy head was instrumented with an array of tri-axial accelerometers mounted at the head centre of gravity. Results Differences in RLA between the roundhouse kick (130.11±51.67 g) and hook punch (71.23±32.19 g, d = 1.39) and in HIC15 (clench axe kick: 162.63±104.10; uppercut: 24.10±12.54, d = 2.29) were observed. Conclusions Taekwondo kicks demonstrated significantly larger magnitudes than boxing punches for both RLA and HIC. PMID:24744497

  10. Robotic mounting of ATLAS barrel SCT modules

    International Nuclear Information System (INIS)

    Nickerson, R.B.; Viehhauser, G.; Wastie, R.; Terada, S.; Unno, Y.; Kohriki, T.; Ikegami, Y.; Hara, K.; Kobayashi, H.; Barbier, G.; Clark, A.G.; Perrin, E.; Carter, A.A.; Mistry, J.; Morris, J.

    2006-01-01

    The 2112 silicon detector modules of the barrel part of the ATLAS SemiConductor Tracker (SCT) have been mounted on their carbon fibre support structure. Module insertion, placement and fixing were performed by robotic assembly tooling. We report on our experience with this assembly method. Part of the mounting sequence involves a partial survey of elements of the support structure which is needed to align the modules properly during insertion. An analysis of these data is used to estimate the positional accuracy of the robots

  11. Sensor mount assemblies and sensor assemblies

    Science.gov (United States)

    Miller, David H [Redondo Beach, CA

    2012-04-10

    Sensor mount assemblies and sensor assemblies are provided. In an embodiment, by way of example only, a sensor mount assembly includes a busbar, a main body, a backing surface, and a first finger. The busbar has a first end and a second end. The main body is overmolded onto the busbar. The backing surface extends radially outwardly relative to the main body. The first finger extends axially from the backing surface, and the first finger has a first end, a second end, and a tooth. The first end of the first finger is disposed on the backing surface, and the tooth is formed on the second end of the first finger.

  12. Diamond-coated probe head for measurements in the deep SOL and beyond

    DEFF Research Database (Denmark)

    Schrittwieser, R.; Xu, G. S.; Yan, Ning

    We have tested two cylindrical graphite probe heads coated by a layer of electrically isolating UNCD (Ultra Nano-Crystalline Diamond) using a CVD (Chemical Vapour Deposition) method. The probe heads were mounted on the reciprocating probe manipulator of the Experimental Advanced Superconducting T...

  13. Fixture For Mounting A Pressure Sensor

    Science.gov (United States)

    Cagle, Christopher M.

    1995-01-01

    Fixture for mounting pressure sensor in aerodynamic model simplifies task of removal and replacement of sensor in event sensor becomes damaged. Makes it unnecessary to dismantle model. Also minimizes any change in aerodynamic characteristics of model in event of replacement. Removable pressure sensor installed in fixture in wall of model. Wires from sensor pass through channel under surface.

  14. Flush-mounting technique for composite beams

    Science.gov (United States)

    Harman, T. C.; Kay, B. F.

    1980-01-01

    Procedure permits mounting of heavy parts to surface of composite beams without appreciably weakening beam web. Web is split and held apart in region where attachment is to be made by lightweight precast foam filler. Bolt hole penetrates foam rather than web, and is secured by barrelnut in transverse bushing through web.

  15. Bearing-Mounting Concept Accommodates Thermal Expansion

    Science.gov (United States)

    Nespodzany, Robert; Davis, Toren S.

    1995-01-01

    Pins or splines allow radial expansion without slippage. Design concept for mounting rotary bearing accommodates differential thermal expansion between bearing and any structure(s) to which bearing connected. Prevents buildup of thermal stresses by allowing thermal expansion to occur freely but accommodating expansion in such way not to introduce looseness. Pin-in-slot configuration also maintains concentricity.

  16. Motion planning for gantry mounted manipulators

    DEFF Research Database (Denmark)

    Olsen, Anders Lau; Petersen, Henrik Gordon

    2007-01-01

    We present a roadmap based planner for finding robot motions for gantry mounted manipulators for a line welding application at Odense Steel Shipyard (OSS). The robot motions are planned subject to constraints on when the gantry may be moved. We show that random sampling of gantry configurations...

  17. Photovoltaic module mounting clip with integral grounding

    Science.gov (United States)

    Lenox, Carl J.

    2010-08-24

    An electrically conductive mounting/grounding clip, usable with a photovoltaic (PV) assembly of the type having an electrically conductive frame, comprises an electrically conductive body. The body has a central portion and first and second spaced-apart arms extending from the central portion. Each arm has first and second outer portions with frame surface-disrupting element at the outer portions.

  18. Mounting LHCb hadron calorimeter scintillating tiles

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    Scintillating tiles are carefully mounted in the hadronic calorimeter for the LHCb detector. These calorimeters measure the energy of particles that interact via the strong force, called hadrons. The detectors are made in a sandwich-like structure where these scintillator tiles are placed between metal sheets.

  19. Solidly Mounted Resonator with Optimized Acoustic Reflector

    NARCIS (Netherlands)

    Jose, Sumy; Jansman, Andreas; Hueting, Raymond Josephus Engelbart

    2009-01-01

    The quality factor (Q) of the Solidly Mounted Resonator is limited by acoustic losses caused by waves leaking through the mirror stack. Traditionally employed acoustic mirror reflects only longitudinal waves and not shear waves. Starting with the stop-band theory and the principle of spacer layers

  20. Dynamic characteristics of mirrors' kinematic mount

    International Nuclear Information System (INIS)

    Wu Wenkai; Du Qiang; Li Jingze; Chen Gang; Chen Xiaojuan; Xu Yuanli

    2002-01-01

    Applying exact constrain design principles, kinematic mount for precision positioning large aperture mirrors is designed; theoretical method is introduced to analyze its dynamic characteristics and the result of the experiment for mirrors, stability; accordingly, the methods to improve design are put forward

  1. Making sense of Mount St. Helens

    Science.gov (United States)

    Steve Nash

    2010-01-01

    The eruption of Mount St. Helens in 1980 resulted in "a grand experiment that you could never have gotten anybody to fund," says Forest Service ecologist Charles Crisafulli. "Everything's new. It's a new landform." Unlike most misbehaving volcanoes, this one provided an accessible laboratory right along the Interstate-5 corridor, with the...

  2. June 1992 Mount Spurr, USA Images

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Following 39 years of inactivity, Crater Peak vent on the south flank of Mount Spurr volcano burst into eruption at 7:04 a.m. Alaska daylight time (ADT) on June 27,...

  3. 49 CFR 587.19 - Mounting.

    Science.gov (United States)

    2010-10-01

    ... Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) DEFORMABLE BARRIERS Offset Deformable Barrier § 587.19 Mounting. (a) The deformable face is rigidly attached to the edge of the fixed rigid barrier or to some rigid...

  4. Head Impact Laboratory (HIL)

    Data.gov (United States)

    Federal Laboratory Consortium — The HIL uses testing devices to evaluate vehicle interior energy attenuating (EA) technologies for mitigating head injuries resulting from head impacts during mine/...

  5. Heading and head injuries in soccer.

    Science.gov (United States)

    Kirkendall, D T; Jordan, S E; Garrett, W E

    2001-01-01

    In the world of sports, soccer is unique because of the purposeful use of the unprotected head for controlling and advancing the ball. This skill obviously places the player at risk of head injury and the game does carry some risk. Head injury can be a result of contact of the head with another head (or other body parts), ground, goal post, other unknown objects or even the ball. Such impacts can lead to contusions, fractures, eye injuries, concussions or even, in rare cases, death. Coaches, players, parents and physicians are rightly concerned about the risk of head injury in soccer. Current research shows that selected soccer players have some degree of cognitive dysfunction. It is important to determine the reasons behind such deficits. Purposeful heading has been blamed, but a closer look at the studies that focus on heading has revealed methodological concerns that question the validity of blaming purposeful heading of the ball. The player's history and age (did they play when the ball was leather and could absorb significant amounts of water), alcohol intake, drug intake, learning disabilities, concussion definition and control group use/composition are all factors that cloud the ability to blame purposeful heading. What does seem clear is that a player's history of concussive episodes is a more likely explanation for cognitive deficits. While it is likely that the subconcussive impact of purposeful heading is a doubtful factor in the noted deficits, it is unknown whether multiple subconcussive impacts might have some lingering effects. In addition, it is unknown whether the noted deficits have any affect on daily life. Proper instruction in the technique is critical because if the ball contacts an unprepared head (as in accidental head-ball contacts), the potential for serious injury is possible. To further our understanding of the relationship of heading, head injury and cognitive deficits, we need to: learn more about the actual impact of a ball on the

  6. Shoulder-Mounted Robot for MRI-guided arthrography: Accuracy and mounting study.

    Science.gov (United States)

    Monfaredi, R; Wilson, E; Sze, R; Sharma, K; Azizi, B; Iordachita, I; Cleary, K

    2015-08-01

    A new version of our compact and lightweight patient-mounted MRI-compatible 4 degree-of-freedom (DOF) robot for MRI-guided arthrography procedures is introduced. This robot could convert the traditional two-stage arthrography procedure (fluoroscopy-guided needle insertion followed by a diagnostic MRI scan) to a one-stage procedure, all in the MRI suite. The results of a recent accuracy study are reported. A new mounting technique is proposed and the mounting stability is investigated using optical and electromagnetic tracking on an anthropomorphic phantom. Five volunteer subjects including 2 radiologists were asked to conduct needle insertion in 4 different random positions and orientations within the robot's workspace and the displacement of the base of the robot was investigated during robot motion and needle insertion. Experimental results show that the proposed mounting method is stable and promising for clinical application.

  7. Head Trauma: First Aid

    Science.gov (United States)

    First aid Head trauma: First aid Head trauma: First aid By Mayo Clinic Staff Most head trauma involves injuries that are minor and don't require ... 21, 2015 Original article: http://www.mayoclinic.org/first-aid/first-aid-head-trauma/basics/ART-20056626 . Mayo ...

  8. Systems and methods for mirror mounting with minimized distortion

    Science.gov (United States)

    Antonille, Scott R. (Inventor); Wallace, Thomas E. (Inventor); Content, David A. (Inventor); Wake, Shane W. (Inventor)

    2012-01-01

    A method for mounting a mirror for use in a telescope includes attaching the mirror to a plurality of adjustable mounts; determining a distortion in the mirror caused by the plurality adjustable mounts, and, if the distortion is determined to be above a predetermined level: adjusting one or more of the adjustable mounts; and determining the distortion in the mirror caused by the adjustable mounts; and in the event the determined distortion is determined to be at or below the predetermined level, rigidizing the adjustable mounts.

  9. Increased earthquake safety through optimised mounting concept

    International Nuclear Information System (INIS)

    Kollmann, Dieter; Senechal, Holger

    2013-01-01

    Since Fukushima, there has been intensive work on earthquake safety in all nuclear power plants. A large part of these efforts aim at the earthquake safety of safety-relevant pipeline systems. The problem with earthquake safety here is not the pipeline system itself but rather its mountings and connections to components. This is precisely the topic that the KAE dealt with in years of research and development work. It has developed an algorithm that determines the optimal mounting concept with a few iteration steps depending on arbitrary combinations of loading conditions whilst maintaining compliance with relevant regulations for any pipeline systems. With this tool at hand, we are now in a position to plan and realise remedial measures accurately with minimum time and hardware expenditure, and so distinctly improve the earthquake safety of safety-relevant systems. (orig.)

  10. Micro-inverter solar panel mounting

    Science.gov (United States)

    Morris, John; Gilchrist, Phillip Charles

    2016-02-02

    Processes, systems, devices, and articles of manufacture are provided. Each may include adapting micro-inverters initially configured for frame-mounting to mounting on a frameless solar panel. This securement may include using an adaptive clamp or several adaptive clamps secured to a micro-inverter or its components, and using compressive forces applied directly to the solar panel to secure the adaptive clamp and the components to the solar panel. The clamps can also include compressive spacers and safeties for managing the compressive forces exerted on the solar panels. Friction zones may also be used for managing slipping between the clamp and the solar panel during or after installation. Adjustments to the clamps may be carried out through various means and by changing the physical size of the clamps themselves.

  11. Head and neck cancer

    International Nuclear Information System (INIS)

    Vogl, S.E.

    1988-01-01

    This book contains 10 chapters. Some of the titles are: Combined Surgical Resection and Irradiation for Head and Neck Cancers; Analysis of Radiation Therapy Oncology Group Head and Neck Database: Identification of Prognostic Factors and the Re-evaluation of American Joint Committee Stages; Combined Modality Approach to Head and Neck Cancer; Induction Combination Chemotherapy of Regionally Advanced Head and Neck Cancer; and Outcome after Complete Remission to Induction Chemotherapy in Head and Neck Cancer

  12. Mapping the Spread of Mounted Warfare

    Directory of Open Access Journals (Sweden)

    Peter Turchin

    2016-12-01

    Full Text Available Military technology is one of the most important factors affecting the evolution of complex societies. In particular, mounted warfare, the use of horse-riders in military operations, revolutionized war as it spread to different parts of Eurasia and Africa during the Ancient and Medieval eras, and to the Americas during the Early Modern period. Here we use a variety of sources to map this spread.

  13. New mounting improves solar-cell efficiency

    Science.gov (United States)

    Shepard, N. F., Jr.

    1980-01-01

    Method boosts output by about 20 percent by trapping and redirecting solar radiation without increasing module depth. Mounted solar-cell array is covered with internally reflecting plate. Plate is attached to each cell by transparent adhesive, and space between cells is covered with layer of diffusely reflecting material. Solar energy falling on space between cells is diffused and reflected internally by plate until it is reflected onto solar cell.

  14. Customer Satisfaction Level in Mount Sherpa Restaurant

    OpenAIRE

    Shrestha, Sameer

    2015-01-01

    Customer satisfaction is the key to every successful business in the sense of profit motive, as well as in the long run. It is the desire of every business to be able to understand their customers’ need. Many businesses, especially related with the service industry, carry out different surveys and conduct research in order to know what their customers really want. This research was carried out to measure the customer satisfaction level in Mount Sherpa restaurant. The results and findings ...

  15. Conceptual design for PSP mounting bracket

    Energy Technology Data Exchange (ETDEWEB)

    Ransom, G.; Stein, R. [Martin Marietta Energy Systems, Inc., Piketon, OH (United States)

    1991-12-31

    Protective structural packages (PSP`s or overpacks) used to ship 2 1/2-ton UF{sub 6} product cylinders are bolted to truck trailers. All bolts penetrate two longitudinal rows of wooden planks. Removal and replacement is required at various intervals for maintenance and routine testing. A conceptual design is presented for mounting brackets which would securely attach PSP`s to trailer frames, reduce removal and replacement time, and minimize risk of personnel injury.

  16. A universal and smart helmet-mounted display of large FOV

    Science.gov (United States)

    Zhang, Nan; Weng, Dongdong; Wang, Yongtian; Li, Xuan; Liu, Youhai

    2011-11-01

    HMD (head-mounted display) is an important virtual reality device, which has played a vital role in VR application system. Compared with traditional HMD which cannot be applied in the daily life owing to their disadvantage on the price and performance, a new universal and smart Helmet-Mounted Display of large FOV uses excellent performance and widespread popularity as its starting point. By adopting simplified visual system and transflective system that combines the transmission-type and reflection-type display system with transflective glass based on the Huggens-Fresnel principle, we have designed a HMD with wide field of view, which can be easy to promote and popularize. Its resolution is 800*600, and field of view is 36.87°(vertical)* 47.92°(horizontal). Its weight is only 1080g. It has caught up with the advanced world levels.

  17. Mounting apparatus for a nozzle guide vane assembly

    Science.gov (United States)

    Boyd, Gary L.; Shaffer, James E.

    1995-01-01

    The present invention provides a ceramic nozzle guide assembly with an apparatus for mounting it to a metal nozzle case that includes an intermediate ceramic mounting ring. The mounting ring includes a plurality of projections that are received within a plurality of receptacles formed in the nozzle case. The projections of the mounting ring are secured within the receptacles by a ceramic retainer that allows contact between the two components only along arcuate surfaces thus eliminating sliding contact between the components.

  18. 46 CFR 61.05-15 - Boiler mountings and attachments.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Boiler mountings and attachments. 61.05-15 Section 61.05... TESTS AND INSPECTIONS Tests and Inspections of Boilers § 61.05-15 Boiler mountings and attachments. (a....05-10. (b) Each stud or bolt for each boiler mounting that paragraph (c) of this section requires to...

  19. Organization and processes of the BN-600 reactor mounting

    International Nuclear Information System (INIS)

    Dubrovin, E.Z.; Karpenko, V.N.; Takhtaulov, V.M.

    1982-01-01

    Structural peculiarities of the BN-600 reactor plant are considered. Experience of metal structure mounting inside the reactor vessel has been analysed. Recommendations on the improvements on the organization of the thermal mechanical equipment mounting are given. It is concluded that the consideration of these recommendations will permit to reduce expenditures of labour by 10-40% for the mounting

  20. [The controversy of routine articulator mounting in orthodontics].

    Science.gov (United States)

    Wang, Li; Han, Xianglong; Bai, Ding

    2013-06-01

    Articulators have been widely used by clinicians of dentistry. But routine articulator mounting is still controversial in orthodontics. Orthodontists oriented by gnathology approve routine articulator mounting while nongnathologic orthodontists disapprove it. This article reviews the thoughts of orthodontist that they agree or disagree with routine articulator mounting based on the considerations of biting, temporomandibular disorder (TMD), periodontitis, and so on.

  1. 49 CFR 571.212 - Standard No. 212; Windshield mounting.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 212; Windshield mounting. 571.212... Motor Vehicle Safety Standards § 571.212 Standard No. 212; Windshield mounting. S1. Scope. This standard..., under the conditions of S6, the windshield mounting of the vehicle shall retain not less than the...

  2. GyroVR: Simulating Inertia in Virtual Reality using Head Worn Flywheels

    DEFF Research Database (Denmark)

    Gugenheimer, Jan; Wolf, Dennis; Eiríksson, Eyþór Rúnar

    2016-01-01

    We present GyroVR, head worn flywheels designed to render inertia in Virtual Reality (VR. Motions such as flying, diving or floating in outer space generate kinesthetic forces onto our body which impede movement and are currently not represented in VR. We simulate those kinesthetic forces...... by attaching flywheels to the users head, leveraging the gyroscopic effect of resistance when changing the spinning axis of rotation. GyroVR is an ungrounded, wireless and self contained device allowing the user to freely move inside the virtual environment. The generic shape allows to attach it to different...... positions on the users body. We evaluated the impact of GyroVR onto different mounting positions on the head (back and front) in terms of immersion, enjoyment and simulator sickness. Our results show, that attaching GyroVR onto the users head (front of the Head Mounted Display (HMD)) resulted in the highest...

  3. Evaluation of Head Mounted and Head Down Information Displays During Simulated Mine-Countermeasures Dives to 42 msw

    Science.gov (United States)

    2008-04-01

    visualisation tête basse (VTB) ou d’un visiocasque pour l’exécution de leurs tâches courantes sous l’eau. Neuf plongeurs de lutte contre les mines ont...existe peu d’information empirique sur l’aptitude des plongeurs à utiliser un dispositif multifonction de visualisation tête basse (VTB) ou d’un...experiment, the diver was also linked to the researchers and operations crew via audio communications. 11 Display Screen Chamber Laptop Diver

  4. ATST telescope mount: telescope of machine tool

    Science.gov (United States)

    Jeffers, Paul; Stolz, Günter; Bonomi, Giovanni; Dreyer, Oliver; Kärcher, Hans

    2012-09-01

    The Advanced Technology Solar Telescope (ATST) will be the largest solar telescope in the world, and will be able to provide the sharpest views ever taken of the solar surface. The telescope has a 4m aperture primary mirror, however due to the off axis nature of the optical layout, the telescope mount has proportions similar to an 8 meter class telescope. The technology normally used in this class of telescope is well understood in the telescope community and has been successfully implemented in numerous projects. The world of large machine tools has developed in a separate realm with similar levels of performance requirement but different boundary conditions. In addition the competitive nature of private industry has encouraged development and usage of more cost effective solutions both in initial capital cost and thru-life operating cost. Telescope mounts move relatively slowly with requirements for high stability under external environmental influences such as wind buffeting. Large machine tools operate under high speed requirements coupled with high application of force through the machine but with little or no external environmental influences. The benefits of these parallel development paths and the ATST system requirements are being combined in the ATST Telescope Mount Assembly (TMA). The process of balancing the system requirements with new technologies is based on the experience of the ATST project team, Ingersoll Machine Tools who are the main contractor for the TMA and MT Mechatronics who are their design subcontractors. This paper highlights a number of these proven technologies from the commercially driven machine tool world that are being introduced to the TMA design. Also the challenges of integrating and ensuring that the differences in application requirements are accounted for in the design are discussed.

  5. A trolley mounted magazine for reactor maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, P.J.; Madani, M.; Ridgway, G.H. [GE Hitachi Nuclear Energy Canada, Peterborough, Ontario (Canada)], E-mail: patrick1.brennan@ge.com, mehdi.madani@ge.com, guy.ridgway@ge.com; Lundy, E.; Knight, D. [IM and CS (Inspection, Maintenance and Commerical Services), Ontario Power Generation, Ajax, Ontario (Canada)], E-mail: erroll.lundy@opg.com, david.knight@opg.com

    2009-03-15

    This paper describes the design of a mechanism incorporating a rotary magazine to be mounted on a fuelling machine transport trolley for use at a Darlington reactor during a feeder replacement or maintenance outage. The magazine stores reactor channel maintenance components, such as channel isolation plugs and vented closure plugs, in twelve available magazine channels. Use of the magazine rather than a fuelling machine reduces the time required to transfer such components between the Central Service Area and reactor channels. Component transfers are accomplished by locking the fuelling machine onto one of the magazine channels and using a local controller to execute commands received from the fuel handling control system. (author)

  6. A trolley mounted magazine for reactor maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, P.J.; Madani, M.; Ridgway, G.H., E-mail: patrick1.brennan@ge.com, E-mail: mehdi.madani@ge.com, E-mail: guy.ridgway@ge.com [GE Hitachi Nuclear Energy Canada, Peterborough, Ontario (Canada); Lundy, E.; Knight, D., E-mail: erroll.lundy@opg.com, E-mail: david.knight@opg.com [Ontario Power Generation, Inspection, Maintenance and Commercial Services, Ajax, Ontario (Canada)

    2008-07-01

    This paper describes the design of a mechanism incorporating a rotary magazine to be mounted on a fuelling machine transport trolley for use at a Darlington reactor during a feeder replacement or maintenance outage. The magazine stores reactor channel maintenance components, such as channel isolation plugs and vented closure plugs, in twelve available magazine channels. Use of the magazine rather than a fuelling machine reduces the time required to transfer such components between the Central Service Area and reactor channels. Component transfers are accomplished by locking the fuelling machine onto one of the magazine channels and using a local controller to execute commands received from the fuel handling control system. (author)

  7. A trolley mounted magazine for reactor maintenance

    International Nuclear Information System (INIS)

    Brennan, P.J.; Madani, M.; Ridgway, G.H.; Lundy, E.; Knight, D.

    2009-01-01

    This paper describes the design of a mechanism incorporating a rotary magazine to be mounted on a fuelling machine transport trolley for use at a Darlington reactor during a feeder replacement or maintenance outage. The magazine stores reactor channel maintenance components, such as channel isolation plugs and vented closure plugs, in twelve available magazine channels. Use of the magazine rather than a fuelling machine reduces the time required to transfer such components between the Central Service Area and reactor channels. Component transfers are accomplished by locking the fuelling machine onto one of the magazine channels and using a local controller to execute commands received from the fuel handling control system. (author)

  8. Mount Zirkel Wilderness and vicinity, Colorado

    International Nuclear Information System (INIS)

    Snyder, G.L.; Patten, L.L.

    1984-01-01

    Several areas of metallic and nonmetallic mineralization have been identified from surface occurrences within the Mount Zirkel Wilderness and vicinity, Colorado. Three areas of probable copper-lead-zinc-silver-gold resource potential, two areas of probable chrome-platinum resource potential, four areas of probable uranium-thorium resource potential, two areas of probable molybdenum resource potential, and one area of probable fluorspar potential were identified by studies in 1965-1973 by the USGS and USBM. No potential for fossil fuel or geothermal resources was identified

  9. A trolley mounted magazine for reactor maintenance

    International Nuclear Information System (INIS)

    Brennan, P.J.; Madani, M.; Ridgway, G.H.; Lundy, E.; Knight, D.

    2008-01-01

    This paper describes the design of a mechanism incorporating a rotary magazine to be mounted on a fuelling machine transport trolley for use at a Darlington reactor during a feeder replacement or maintenance outage. The magazine stores reactor channel maintenance components, such as channel isolation plugs and vented closure plugs, in twelve available magazine channels. Use of the magazine rather than a fuelling machine reduces the time required to transfer such components between the Central Service Area and reactor channels. Component transfers are accomplished by locking the fuelling machine onto one of the magazine channels and using a local controller to execute commands received from the fuel handling control system. (author)

  10. Head injury - first aid

    Science.gov (United States)

    ... medlineplus.gov/ency/article/000028.htm Head injury - first aid To use the sharing features on this page, ... a concussion can range from mild to severe. First Aid Learning to recognize a serious head injury and ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the head uses special x-ray equipment to help assess head injuries, severe headaches, dizziness, and other ... aneurysm, bleeding, stroke and brain tumors. It also helps your doctor to evaluate your face, sinuses, and ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  15. Research on LQR optimal control method of active engine mount

    Science.gov (United States)

    Huan, Xie; Yu, Duan

    2018-04-01

    In this paper, the LQR control method is applied to the active mount of the engine, and a six-cylinder engine excitation model is established. Through the joint simulation of AMESim and MATLAB, the vibration isolation performance of the active mount system and the passive mount system is analyzed. Excited by the multi-engine operation, the simulation results of the vertical displacement, acceleration and dynamic deflection of the vehicle body show that the vibration isolation capability of the active mount system is superior to that of the passive mount system. It shows that compared with the passive mount, LQR active mount can greatly improve the vibration isolation performance, which proves the feasibility and effectiveness of the LQR control method.

  16. A new optimization approach for nozzle selection and component allocation in multi-head beam-type SMD placement machines

    NARCIS (Netherlands)

    Torabi, S.A.; Hamedi, M.; Ashayeri, J.

    2013-01-01

    This paper addresses a highly challenging scheduling problem faced in multi-head beam-type surface mounting devices (SMD) machines. An integrated mathematical model is formulated aiming to balance workloads over multiple heads as well as improving the traveling speed of the robotic arm by

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  18. Evaluation of shear mounted elastomeric damper

    Science.gov (United States)

    Zorzi, E.; Walton, J.

    1982-01-01

    Viton-70 elastomeric shear mounted damper was built and tested on a T-55 power turbine spool in the rotor's high speed balancing rig. This application of a shear mounted elastomeric damper demonstrated for the first time, the feasibility of using elastomers as the primary rotor damping source in production turbine engine hardware. The shear damper design was selected because it was compatible with actual gas turbine engine radial space constraints, could accommodate both the radial and axial thrust loads present in gas turbine engines, and was capable of controlled axial preload. The shear damper was interchangeable with the production T-55 power turbine roller bearing support so that a direct comparison between the shear damper and the production support structure could be made. Test results show that the Viton-70 elastomer damper operated successfully and provided excellent control of both synchronous and nonsynchronous vibrations through all phases of testing up to the maximum rotor speed of 16,000 rpm. Excellent correlation between the predicted and experienced critical speeds, mode shapes and log decrements for the power turbine rotor and elastomer damper assembly was also achieved.

  19. Experience with HEP analysis on mounted filesystems

    International Nuclear Information System (INIS)

    Fuhrmann, Patrick; Gasthuber, Martin; Kemp, Yves; Ozerov, Dmitry

    2012-01-01

    We present results on different approaches on mounted filesystems in use or under investigation at DESY. dCache, established since long as a storage system for physics data has implemented the NFS v4.1/pNFS protocol. New performance results will be shown with the most current version of the dCache server. In addition to the native usage of the mounted filesystem in a LAN environment, the results are given for the performance of the dCache NFS v4.1/pNFS in WAN case. Several commercial vendors are currently in alpha or beta phase of adding the NFS v4.1/pNFS protocol to their storage appliances. We will test some of these vendor solutions for their readiness for HEP analysis. DESY has recently purchased an IBM Sonas system. We will present the result of a thorough performance evaluation using the native protocols NFS (v3 or v4) and GPFS. As the emphasis is on the usability for end user analysis, we will use latest ROOT versions and current end user analysis code for benchmark scenarios.

  20. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  1. Improved resolution by mounting of tissue sections for laser microdissection.

    Science.gov (United States)

    van Dijk, M C R F; Rombout, P D M; Dijkman, H B P M; Ruiter, D J; Bernsen, M R

    2003-08-01

    Laser microbeam microdissection has greatly facilitated the procurement of specific cell populations from tissue sections. However, the fact that a coverslip is not used means that the morphology of the tissue sections is often poor. To develop a mounting method that greatly improves the morphological quality of tissue sections for laser microbeam microdissection purposes so that the identification of target cells can be facilitated. Fresh frozen tissue and formalin fixed, paraffin wax embedded tissue specimens were used to test the morphological quality of mounted and unmounted tissue. The mounting solution consisted of an adhesive gum and blue ink diluted in water. Interference of the mounting solution with DNA quality was analysed by the polymerase chain reaction using 10-2000 cells isolated by microdissection from mounted and unmounted tissue. The mounting solution greatly improved the morphology of tissue sections for laser microdissection purposes and had no detrimental effects on the isolation and efficiency of amplification of DNA. One disadvantage was that the mounting solution reduced the cutting efficiency of the ultraviolet laser. To minimise this effect, the mounting solution should be diluted as much as possible. Furthermore, the addition of blue ink to the mounting medium restores the cutting efficiency of the laser. The mounting solution is easy to prepare and apply and can be combined with various staining methods without compromising the quality of the DNA extracted.

  2. Eruptive history of Mount Katmai, Alaska

    Science.gov (United States)

    Hildreth, Edward; Fierstein, Judith

    2012-01-01

    Mount Katmai has long been recognized for its caldera collapse during the great pyroclastic eruption of 1912 (which vented 10 km away at Novarupta in the Valley of Ten Thousand Smokes), but little has previously been reported about the geology of the remote ice-clad stratovolcano itself. Over several seasons, we reconnoitered all parts of the edifice and sampled most of the lava flows exposed on its flanks and caldera rim. The precipitous inner walls of the 1912 caldera remain too unstable for systematic sampling; so we provide instead a photographic and interpretive record of the wall sequences exposed. In contrast to the several andesite-dacite stratovolcanoes nearby, products of Mount Katmai range from basalt to rhyolite. Before collapse in 1912, there were two overlapping cones with separate vent complexes and craters; their products are here divided into eight sequences of lava flows, agglutinates, and phreatomagmatic ejecta. Latest Pleistocene and Holocene eruptive units include rhyodacite and rhyolite lava flows along the south rim; a major 22.8-ka rhyolitic plinian fall and ignimbrite deposit; a dacite-andesite zoned scoria fall; a thick sheet of dacite agglutinate that filled a paleocrater and draped the west side of the edifice; unglaciated leveed dacite lava flows on the southeast slope; and the Horseshoe Island dacite dome that extruded on the caldera floor after collapse. Pre-collapse volume of the glaciated Katmai edifice was ∼30 km3, and eruptive volume is estimated to have been 57±13 km3. The latter figure includes ∼40±6 km3 for the edifice, 5±2 km3 for off-edifice dacite pyroclastic deposits, and 12±5 km3 for the 22.8-ka rhyolitic pyroclastic deposits. To these can be added 13.5 km3 of magma that erupted at Novarupta in 1912, all or much of which is inferred to have been withdrawn from beneath Mount Katmai. The oldest part of the edifice exposed is a basaltic cone, which gave a 40Ar/39Ar plateau age of 89 ± 25 ka.

  3. Development and Application of a Wireless, Networked Raspberry Pi Controlled Head Mounted Tactile Display (HMTD)

    Science.gov (United States)

    2016-09-01

    capable of delivering 2 × 2.8 W channels into 4-ohm impedance speakers. It is available at online electronic retailers (such as Adafruit) for less...10 Wh. It also is available at online electronic retailers , for less than $15. Fig. 8 Lithium ion polymer battery7 Since the RPi is powered by...general acceptance, we used the recommended Raspbian OS. The OS is stored and installed on a micro-SD card. One can purchase a micro- SD card with a

  4. Virtual Reality Design: How Head-Mounted Displays Change Design Paradigms of Virtual Reality Worlds

    Directory of Open Access Journals (Sweden)

    Christian Stein

    2016-09-01

    Full Text Available With the upcoming generation of virtual reality HMDs, new virtual worlds, scenarios, and games are created especially for them. These are no longer bound to a remote screen or a relatively static user, but to an HMD as a more immersive device. This article discusses requirements for virtual scenarios implemented in new-generation HMDs to achieve a comfortable user experience. Furthermore, the effects of positional tracking are introduced and the relation between the user’s virtual and physical body is analyzed. The observations made are exemplified by existing software prototypes. They indicate how the term “virtual reality,” with all its loaded connotations, may be reconceptualized to express the peculiarities of HMDs in the context of gaming, entertainment, and virtual experiences.

  5. Effect of the Oculus Rift head mounted display on postural stability

    DEFF Research Database (Denmark)

    Epure, Paula; Gheorghe, Cristina; Nissen, Thomas

    2014-01-01

    board controlling a skiing game. Two tests were conducted: full-vision versus blindfolded and HMD versus monitor display. Results were that five of the six balance-impaired adults and six of the eight non-balance-impaired adults showed higher degree of postural stability while using a monitor display......This study explored how a HMD-experienced virtual environment influences physical balance of six balance-impaired adults 59-69 years-of-age, when compared to a control group of eight non-balance-impaired adults, 18-28 years-of-age. The setup included a Microsoft Kinect and a self-created balance....... Conclusions are that HMD, used in this context, leads to postural instability....

  6. Visual Stability of Objects and Environments Viewed through Head-Mounted Displays

    Science.gov (United States)

    Ellis, Stephen R.; Adelstein, Bernard D.

    2015-01-01

    Virtual Environments (aka Virtual Reality) is again catching the public imagination and a number of startups (e.g. Oculus) and even not-so-startup companies (e.g. Microsoft) are trying to develop display systems to capitalize on this renewed interest. All acknowledge that this time they will get it right by providing the required dynamic fidelity, visual quality, and interesting content for the concept of VR to take off and change the world in ways it failed to do so in past incarnations. Some of the surprisingly long historical background of the technology that the form of direct simulation that underlies virtual environment and augmented reality displays will be briefly reviewed. An example of a mid 1990's augmented reality display system with good dynamic performance from our lab will be used to illustrate some of the underlying phenomena and technology concerning visual stability of virtual environments and objects during movement. In conclusion some idealized performance characteristics for a reference system will be proposed. Interestingly, many systems more or less on the market now may actually meet many of these proposed technical requirements. This observation leads to the conclusion that the current success of the IT firms trying to commercialize the technology will depend on the hidden costs of using the systems as well as the development of interesting and compelling content.

  7. Game-Based Evacuation Drill Using Augmented Reality and Head-Mounted Display

    Science.gov (United States)

    Kawai, Junya; Mitsuhara, Hiroyuki; Shishibori, Masami

    2016-01-01

    Purpose: Evacuation drills should be more realistic and interactive. Focusing on situational and audio-visual realities and scenario-based interactivity, the authors have developed a game-based evacuation drill (GBED) system that presents augmented reality (AR) materials on tablet computers. The paper's current research purpose is to improve…

  8. An Evaluation of Signal Annoyance for a Head-Mounted Tactile Display

    Science.gov (United States)

    2015-03-01

    communications. Proceedings of the Human Factors and Ergonomics Society 50th Annual Meeting; 2006 Oct 16–20; San Francisco, CA. Thousand Oaks (CA): SAGE...Computer Society; 2005:471–472. Knapp TR. Treating ordinal scales as interval scales: an attempt to resolve the controversy. Nursing Research...Gonzalez C, Baldwin CL. Perceived urgency scaling in tactile alerts. Proceedings of the Human Factors and Ergonomics Society 56th Annual Meeting

  9. Wearable Laser Pointer Versus Head-mounted Display for Tele-guidance Applications?

    DEFF Research Database (Denmark)

    Jalaliniya, Shahram; Pederson, Thomas; Houben, Steven

    2014-01-01

    Wearable camera and display technology allow remote collaborators to guide activities performed by human agents located elsewhere. This kind of technology augments the range of human perception and actuation. In this paper we quantitatively determine if wearable laser pointers are viable...

  10. Jedi training: playful evaluation of head-mounted augmented reality display systems

    Science.gov (United States)

    Ozbek, Christopher S.; Giesler, Bjorn; Dillmann, Ruediger

    2004-05-01

    A fundamental decision in building augmented reality (AR) systems is how to accomplish the combining of the real and virtual worlds. Nowadays this key-question boils down to the two alternatives video-see-through (VST) vs. optical-see-through (OST). Both systems have advantages and disadvantages in areas like production-simplicity, resolution, flexibility in composition strategies, field of view etc. To provide additional decision criteria for high dexterity, accuracy tasks and subjective user-acceptance a gaming environment was programmed that allowed good evaluation of hand-eye coordination, and that was inspired by the Star Wars movies. During an experimentation session with more than thirty participants a preference for optical-see-through glasses in conjunction with infra-red-tracking was found. Especially the high-computational demand for video-capture, processing and the resulting drop in frame rate emerged as a key-weakness of the VST-system.

  11. Visual strain : a comparison of monitors and head-mounted displays

    NARCIS (Netherlands)

    Kooi, F.L.

    1997-01-01

    New methods to measure information uptake and eye strain have been developed. The speed of information uptake is measured with a reading task that demands quick and accurate eyemovements. Accommodative facility is shown to be a good measure for eye strain. A standard monitor and three types of HMDs

  12. Ergonomic evaluation of ubiquitous computing with monocular head-mounted display

    Science.gov (United States)

    Kawai, Takashi; Häkkinen, Jukka; Yamazoe, Takashi; Saito, Hiroko; Kishi, Shinsuke; Morikawa, Hiroyuki; Mustonen, Terhi; Kaistinen, Jyrki; Nyman, Göte

    2010-01-01

    In this paper, the authors conducted an experiment to evaluate the UX in an actual outdoor environment, assuming the casual use of monocular HMD to view video content while short walking. In conducting the experiment, eight subjects were asked to view news videos on a monocular HMD while walking through a large shopping mall. Two types of monocular HMDs and a hand-held media player were used, and the psycho-physiological responses of the subjects were measured before, during, and after the experiment. The VSQ, SSQ and NASA-TLX were used to assess the subjective workloads and symptoms. The objective indexes were heart rate and stride and a video recording of the environment in front of the subject's face. The results revealed differences between the two types of monocular HMDs as well as between the monocular HMDs and other conditions. Differences between the types of monocular HMDs may have been due to screen vibration during walking, and it was considered as a major factor in the UX in terms of the workload. Future experiments to be conducted in other locations will have higher cognitive loads in order to study the performance and the situation awareness to actual and media environments.

  13. Rack assembly for mounting solar modules

    Science.gov (United States)

    Plaisted, Joshua Reed; West, Brian

    2010-12-28

    A rack assembly is provided for mounting solar modules over an underlying body. The rack assembly may include a plurality of rail structures that are arrangeable over the underlying body to form an overall perimeter for the rack assembly. One or more retention structures may be provided with the plurality of rail structures, where each retention structure is configured to support one or more solar modules at a given height above the underlying body. At least some of the plurality of rail structures are adapted to enable individual rail structures o be sealed over the underlying body so as to constrain air flow underneath the solar modules. Additionally, at least one of (i) one or more of the rail structures, or (ii) the one or more retention structures are adjustable so as to adapt the rack assembly to accommodate solar modules of varying forms or dimensions.

  14. Article mounting and position adjustment stage

    Science.gov (United States)

    Cutburth, Ronald W.; Silva, Leonard L.

    1988-01-01

    An improved adjustment and mounting stage of the type used for the detection of laser beams is disclosed. A ring sensor holder has locating pins on a first side thereof which are positioned within a linear keyway in a surrounding housing for permitting reciprocal movement of the ring along the keyway. A rotatable ring gear is positioned within the housing on the other side of the ring from the linear keyway and includes an oval keyway which drives the ring along the linear keyway upon rotation of the gear. Motor-driven single-stage and dual (x, y) stage adjustment systems are disclosed which are of compact construction and include a large laser transmission hole.

  15. MOUNT HOOD WILDERNESS AND ADJACENT AREAS, OREGON.

    Science.gov (United States)

    Keith, T.E.C.; Causey, J.D.

    1984-01-01

    A mineral survey of the Mount Hood Wilderness, Oregon, was conducted. Geochemical data indicate two areas of substantiated mineral-resource potential containing weak epithermal mineralization: an area of the north side of Zigzag Mountain where vein-type lead-zinc-silver deposits occur and an area of the south side of Zigzag Mountain, where the upper part of a quartz diorite pluton has propylitic alteration associated with mineralization of copper, gold, silver, lead, and zinc in discontinuous veins. Geothermal-resource potential for low- to intermediate-temperature (less than 248 degree F) hot-water systems in the wilderness is probable in these areas. Part of the wilderness is classified as a Known Geothermal Resource Area (KGRA), which is considered to have probable geothermal-resource potential, and two parts of the wilderness have been included in geothermal lease areas.

  16. Photovoltaic array mounting apparatus, systems, and methods

    Science.gov (United States)

    West, John Raymond; Atchley, Brian; Hudson, Tyrus Hawkes; Johansen, Emil

    2014-12-02

    An apparatus for mounting a photovoltaic (PV) module on a surface, including a support with an upper surface, a lower surface, tabs, one or more openings, and a clip comprising an arm and a notch, where the apparatus resists wind forces and seismic forces and creates a grounding electrical bond between the PV module, support, and clip. The invention further includes a method for installing PV modules on a surface that includes arranging supports in rows along an X axis and in columns along a Y axis on a surface such that in each row the distance between two neighboring supports does not exceed the length of the longest side of a PV module and in each column the distance between two neighboring supports does not exceed the length of the shortest side of a PV module.

  17. Insectivore Plants Nepenthes sp. at Mount Merbabu

    Directory of Open Access Journals (Sweden)

    AHMAD DWI SETYAWAN

    2000-07-01

    Full Text Available The aims of the research were to know the existence of the Nepenthes at mount Merbabu, variations of its morphology, associated plants, and ecological conditions. Nepenthes are one of plants that were categorized as conserved plant by Indonesian government as indicated in PPRI No. 7/1999. Many researchers attracted to study this unique plant since it’s distinct feature and the way to get nutrient by trapping insects at its sac. Samples were taken randomly along the path for climbing from Selo, Boyolali to the top of the mountain between April to May 2000. The results show that the plants were found at the altitude of around 1500 to 2000 tsl. There were two forms of the sacs, long and short at the same individual plants. The plants grow coiling on Myristica trees and shrubs of Thunbergia fragrans Roxb., and also could grow at the stoned-soil.

  18. Robotized Surface Mounting of Permanent Magnets

    Directory of Open Access Journals (Sweden)

    Erik Hultman

    2014-10-01

    Full Text Available Using permanent magnets on a rotor can both simplify the design and increase the efficiency of electric machines compared to using electromagnets. A drawback, however, is the lack of existing automated assembly methods for large machines. This paper presents and motivates a method for robotized surface mounting of permanent magnets on electric machine rotors. The translator of the Uppsala University Wave Energy Converter generator is used as an example of a rotor. The robot cell layout, equipment design and assembly process are presented and validated through computer simulations and experiments with prototype equipment. A comparison with manual assembly indicates substantial cost savings and an improved work environment. By using the flexibility of industrial robots and a scalable equipment design, it is possible for this assembly method to be adjusted for other rotor geometries and sizes. Finally, there is a discussion on the work that remains to be done on improving and integrating the robot cell into a production line.

  19. MOUNT PELE, AN ECOCLIMATIC GRADIENT GENERATOR

    Directory of Open Access Journals (Sweden)

    PHILIPPE JOSEPH

    2013-05-01

    Full Text Available Generally, mountains determine the characteristics of particular areas, because of the island phenomenon they cause. However, the geological origins of mountains are multiple and they are located in different climatic regions. Nevertheless, in all aspects they reflect the basic elements of the local biologic unit. The shapes, climates, diverse water resources, biocenoses and the generated soils are the different components that determine, through their dynamic interaction, the “Mountain” ecosystem. Tectonic subduction processes lead to the development of islands such as Martinique, whose basic structure consists of a series of mountains (among them Mount Pele. Like the topographic divisions, the local micro-climates, water courses, different soils (themselves the consequences of the presence of the mountain itself and successive volcanic eruptions determine, over time, the organization of the diverse vegetal entities.

  20. Hall Current Plasma Source Having a Center-Mounted or a Surface-Mounted Cathode

    Science.gov (United States)

    Martinez, Rafael A. (Inventor); Williams, John D. (Inventor); Moritz, Jr., Joel A. (Inventor); Farnell, Casey C. (Inventor)

    2018-01-01

    A miniature Hall current plasma source apparatus having magnetic shielding of the walls from ionized plasma, an integrated discharge channel and gas distributor, an instant-start hollow cathode mounted to the plasma source, and an externally mounted keeper, is described. The apparatus offers advantages over other Hall current plasma sources having similar power levels, including: lower mass, longer lifetime, lower part count including fewer power supplies, and the ability to be continuously adjustable to lower average power levels using pulsed operation and adjustment of the pulse duty cycle. The Hall current plasma source can provide propulsion for small spacecraft that either do not have sufficient power to accommodate a propulsion system or do not have available volume to incorporate the larger propulsion systems currently available. The present low-power Hall current plasma source can be used to provide energetic ions to assist the deposition of thin films in plasma processing applications.

  1. Galvanic coupling effects for module-mounting elements of ground-mounted photovoltaic power station

    Directory of Open Access Journals (Sweden)

    Pierozynski Boguslaw

    2017-12-01

    Full Text Available This communication reports on the concerns associated with possible generation of galvanic coupling effects for construction materials that are used to manufacture mounting assemblies for ground-mounted photovoltaic (PV power stations. For this purpose, six macro-corrosion galvanic cells were assembled, including: hot-dip Zn/Magnelis®-coated steel/Al and stainless steel (SS/Al cells. Corrosion experiments involved continuous, ca. three-month exposure of these couplings in 3 wt.% NaCl solution, conducted at room temperature for a stable pH value of around 8. All corrosion cells were subjected to regular assessment of galvanic current-density and potential parameters, where special consideration was given to compare the corrosion behaviour of Zn-coated steel samples with that of Magnelis®-coated electrodes. Characterization of surface condition and elemental composition for examined materials was carried-out by means of SEM and EDX spectroscopy techniques.

  2. Head CT scan

    Science.gov (United States)

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  3. Bottom head assembly

    International Nuclear Information System (INIS)

    Fife, A.B.

    1998-01-01

    A bottom head dome assembly is described which includes, in one embodiment, a bottom head dome and a liner configured to be positioned proximate the bottom head dome. The bottom head dome has a plurality of openings extending there through. The liner also has a plurality of openings extending there through, and each liner opening aligns with a respective bottom head dome opening. A seal is formed, such as by welding, between the liner and the bottom head dome to resist entry of water between the liner and the bottom head dome at the edge of the liner. In the one embodiment, a plurality of stub tubes are secured to the liner. Each stub tube has a bore extending there through, and each stub tube bore is coaxially aligned with a respective liner opening. A seat portion is formed by each liner opening for receiving a portion of the respective stub tube. The assembly also includes a plurality of support shims positioned between the bottom head dome and the liner for supporting the liner. In one embodiment, each support shim includes a support stub having a bore there through, and each support stub bore aligns with a respective bottom head dome opening. 2 figs

  4. Local Community Entrepreneurship in Mount Agung Trekking

    Science.gov (United States)

    Mudana, I. G.; Sutama, I. K.; Widhari, C. I. S.

    2018-01-01

    Since its last major eruption in 1963, Mount Agung in Selat District, Karangasem Regency, the highest mountain in Bali Province began to be visited by tourists climbers. Because of the informal obligation that every climbing/trekking should be guided by local guides, since the 1990s, there have been initiatives from a number of local community members to serve climbing tourists who were keen to climb the volcano/mountain. This study was conducted to understand and describe the entrepreneurial practices which appeared in the local surrounding community. Specifically, Selat Village, in guiding the climbing/trekking. This study used qualitative data analysis and its theories were adapted to data needed in the field. The results of study showed that Mount Agung was considered attractive by climbing tourists not only because of the exotic beauty and challenges of difficulty (as well as the level of danger) to conquer it, but also because it kept certain myths from its status as a holy/sacred mountain to Balinese Hindus. In fact, a number of tourists who did the climbing/trekking without being guided very often got lost, harmed in an accident, or fell to their death. As a direct result, all climbing activities require guidance. Especially guides from local community organizations who really understand the intricacies of climbing and the curvature of the mountain. The entrepreneurial practices of Selat Village community had arisen not only to serve usual climbing activities, but also to preserve the environment of the mountain and the safety of the climbing tourists with the many taboos related to the climb. These facts could be seen clearly from descriptions of local experts and local climbing guides who have been doing their work for years. As a form of entrepreneurship, they basically did their work for the main purpose of seeking livelihoods (or making money) but their responsibility as local people made them commit to guarding the sanctity of the mountain. This was

  5. Flush mounting of thin film sensors

    Science.gov (United States)

    Moore, Thomas C., Sr. (Inventor)

    1992-01-01

    Flush mounting of a sensor on a surface is provided by first forming a recessed area on the surface. Next, an adhesive bonding mixture is introduced into the recessed area. The adhesive bonding mixture is chosen to provide thermal expansion matching with the surface surrounding the recessed area. A strip of high performance polymeric tape is provided, with the sensor attached to the underside thereof, and the tape is positioned over the recessed area so that it acts as a carrier of the sensor. A shim having flexibility so that it will conform to the surface surrounding the recessed area is placed over the tape, and a vacuum pad is placed over the shim. The area above the surface is then evacuated while holding the sensor flush with the surface during curing of the adhesive bonding mixture. After such curing, the pad, shim, and tape are removed from the sensor, electrical connections for the sensor are provided, after which the remaining space in the recessed area is filled with a polymeric foam.

  6. Alternative mounting media for preservation of some protozoa.

    Science.gov (United States)

    Criado-Fornelio, A; Heredero-Bermejo, I; Pérez-Serrano, J

    2014-10-01

    Protozoa resistant stages are disintegrated when mounted in toluene-based media. To overcome such problem, three toluene-free mountants were tested on preserve Acanthamoeba spp and gregarines. Two commercial glues based on cyanoacrylate or trimethoxysilane were suitable for preserving both cysts and trophozoites. Hoyer's medium showed good results for mounting gregarine oocysts. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Hole-thru-laminate mounting supports for photovoltaic modules

    Science.gov (United States)

    Wexler, Jason; Botkin, Jonathan; Culligan, Matthew; Detrick, Adam

    2015-02-17

    A mounting support for a photovoltaic module is described. The mounting support includes a pedestal having a surface adaptable to receive a flat side of a photovoltaic module laminate. A hole is disposed in the pedestal, the hole adaptable to receive a bolt or a pin used to couple the pedestal to the flat side of the photovoltaic module laminate.

  8. Solar electricity potentials and optimal angles for mounting solar ...

    African Journals Online (AJOL)

    The need for harnessing solar energy using solar panels mounted at optimal inclination angles in the six geopolitical zones of Nigeria is presented. The optimal angle for mounting solar panels as presented by Photovoltaic Geographic Information System (PVGIS) ranges from 11º to 14º in the Southern zone and 13º to 16º ...

  9. Wind instrument mountings for above-the-cab lookout exposure

    Science.gov (United States)

    Owen P. Cramer; Ralph H. Moltzau

    1968-01-01

    The lookout tower offers a ready-made platform from which the speed of true unobstructed wind can be measured, then reduced to equivalent of 20-foot wind. Tower-mounted instruments must meet the requirements of a lightning conductor system, but should also be easily installed and removed for storage and maintenance. Lightweight aluminum mountings for catwalk or flat-...

  10. The alpine flora of Mount Wilhelm (New Guinea)

    NARCIS (Netherlands)

    Hoogland, R.D.

    1958-01-01

    The flora of the higher mountains of New Guinea has been the object of several extensive collecting trips in the past forty years. Until quite recently, however, a serious gap in our knowledge was the very scanty information available from the area between Mount Wilhelmina in the West and Mount

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  13. Optimization of Classical Hydraulic Engine Mounts Based on RMS Method

    Directory of Open Access Journals (Sweden)

    J. Christopherson

    2005-01-01

    Full Text Available Based on RMS averaging of the frequency response functions of the absolute acceleration and relative displacement transmissibility, optimal parameters describing the hydraulic engine mount are determined to explain the internal mount geometry. More specifically, it is shown that a line of minima exists to define a relationship between the absolute acceleration and relative displacement transmissibility of a sprung mass using a hydraulic mount as a means of suspension. This line of minima is used to determine several optimal systems developed on the basis of different clearance requirements, hence different relative displacement requirements, and compare them by means of their respective acceleration and displacement transmissibility functions. In addition, the transient response of the mount to a step input is also investigated to show the effects of the optimization upon the time domain response of the hydraulic mount.

  14. Perspective with Landsat Overlay, Mount Kilimanjaro, Tanzania

    Science.gov (United States)

    2002-01-01

    Mount Kilimanjaro (Kilima Njaro or 'shining mountain' in Swahili), the highest point in Africa, reaches 5,895 meters (19,340 feet) above sea level, tall enough to maintain a permanent snow cap despite being just 330 kilometers (210 miles) south of the equator. It is the tallest free-standing mountain on the Earth's land surface world, rising about 4,600 meters (15,000 feet) above the surrounding plain. Kilimanjaro is a triple volcano (has three peaks) that last erupted perhaps more than 100,000 years ago but still exudes volcanic gases. It is accompanied by about 20 other nearby volcanoes, some of which are seen to the west (left) in this view, prominently including Mount Meru, which last erupted only about a century ago. The volcanic mountain slopes are commonly fertile and support thick forests, while the much drier grasslands of the plains are home to elephants, lions, and other savanna wildlife.This 3-D perspective view was generated using topographic data from the Shuttle Radar Topography Mission (SRTM), a Landsat 7 satellite image, and a false sky. Topographic expression is vertically exaggerated two times.Landsat has been providing visible and infrared views of the Earth since 1972. SRTM elevation data matches the 30-meter (98-foot) resolution of most Landsat images and will substantially help in analyzing the large and growing Landsat image archive, managed by the U.S. Geological Survey (USGS).Elevation data used in this image was acquired by the Shuttle Radar Topography Mission (SRTM) aboard the Space Shuttle Endeavour, launched on Feb. 11, 2000. SRTM used the same radar instrument that comprised the Spaceborne Imaging Radar-C/X-Band Synthetic Aperture Radar (SIR-C/X-SAR) that flew twice on the Space Shuttle Endeavour in 1994. SRTM was designed to collect 3-D measurements of the Earth's surface. To collect the 3-D data, engineers added a 60-meter (approximately 200-foot) mast, installed additional C-band and X-band antennas, and improved tracking and

  15. Banner clouds observed at Mount Zugspitze

    Directory of Open Access Journals (Sweden)

    V. Wirth

    2012-04-01

    Full Text Available Systematic observations of banner clouds at Mount Zugspitze in the Bavarian Alps are presented and discussed. One set of observations draws on daily time lapse movies, which were taken over several years at this mountain. Identifying banner clouds with the help of these movies and using simultaneous observations of standard variables at the summit of the mountain provides climatological information regarding the banner clouds. In addition, a week-long measurement campaign with an entire suite of instruments was carried through yielding a comprehensive set of data for two specific banner cloud events.

    The duration of banner cloud events has a long-tailed distribution with a mean of about 40 min. The probability of occurrence has both a distinct diurnal and a distinct seasonal cycle, with a maximum in the afternoon and in the warm season, respectively. These cycles appear to correspond closely to analogous cycles of relative humidity, which maximize in the late afternoon and during the warm season. In addition, the dependence of banner cloud occurrence on wind speed is weak. Both results suggest that moisture conditions are a key factor for banner cloud occurrence. The distribution of wind direction during banner cloud events slightly deviates from climatology, suggesting an influence from the specific Zugspitz orography.

    The two banner cloud events during the campaign have a number of common features: the windward and the leeward side are characterized by different wind regimes, however, with mean upward flow on both sides; the leeward air is both moister and warmer than the windward air; the background atmosphere has an inversion just above the summit of Mt. Zugspitze; the lifting condensation level increases with altitude. The results are discussed, and it is argued that they are consistent with previous Large Eddy Simulations using idealized orography.

  16. Gravity Probe B Detector Mount Assembly

    Science.gov (United States)

    2004-01-01

    In this photo, the Gravity Probe B (GP-B) detector mount assembly is shown in comparison to the size of a dime. The assembly is used to detect exactly how much starlight is coming through different beams from the beam splitter in the telescope. The measurements from the tiny chips inside are what keeps GP-B aimed at the guide star. The GP-B is the relativity experiment developed at Stanford University to test two extraordinary predictions of Albert Einstein's general theory of relativity. The experiment will measure, very precisely, the expected tiny changes in the direction of the spin axes of four gyroscopes contained in an Earth-orbiting satellite at a 400-mile altitude. So free are the gyroscopes from disturbance that they will provide an almost perfect space-time reference system. They will measure how space and time are very slightly warped by the presence of the Earth, and, more profoundly, how the Earth's rotation very slightly drags space-time around with it. These effects, though small for the Earth, have far-reaching implications for the nature of matter and the structure of the Universe. GP-B is among the most thoroughly researched programs ever undertaken by NASA. This is the story of a scientific quest in which physicists and engineers have collaborated closely over many years. Inspired by their quest, they have invented a whole range of technologies that are already enlivening other branches of science and engineering. Launched April 20, 2004 , the GP-B program was managed for NASA by the Marshall Space Flight Center. Development of the GP-B is the responsibility of Stanford University along with major subcontractor Lockheed Martin Corporation. (Image credit to Paul Ehrensberger, Stanford University.)

  17. Installation of a Roof Mounted Photovoltaic System

    Science.gov (United States)

    Lam, M.

    2015-12-01

    In order to create a safe and comfortable environment for students to learn, a lot of electricity, which is generated from coal fired power plants, is used. Therefore, ISF Academy, a school in Hong Kong with approximately 1,500 students, will be installing a rooftop photovoltaic (PV) system with 302 solar panels. Not only will these panels be used to power a classroom, they will also serve as an educational opportunity for students to learn about the importance of renewable energy technology and its uses. There were four different options for the installation of the solar panels, and the final choice was made based on the loading capacity of the roof, considering the fact that overstressing the roof could prove to be a safety hazard. Moreover, due to consideration of the risk of typhoons in Hong Kong, the solar panel PV system will include concrete plinths as counterweights - but not so much that the roof would be severely overstressed. During and after the installation of the PV system, students involved would be able to do multiple calculations, such as determining the reduction of the school's carbon footprint. This can allow students to learn about the impact renewable energy can have on the environment. Another project students can participate in includes measuring the efficiency of the solar panels and how much power can be produced per year, which in turn can help with calculate the amount of money saved per year and when we will achieve economic parity. In short, the installation of the roof mounted PV system will not only be able to help save money for the school but also provide learning opportunities for students studying at the ISF Academy.

  18. Quasi-optical grill mounted in hyperguide

    International Nuclear Information System (INIS)

    Preinhaelter, J.

    1995-04-01

    A proposal is given of a new launcher of lower hybrid waves for the current drive in future big thermonuclear facilities operating in the 10 GHz frequency range. The principle has been combined of the quasi-optical grill with the concepts of the hyperguide and the multiinjection grill. As an example, a six rod structure model was optimized mounted in a oversized waveguide and irradiated by the oblique plane wave emerging in the form of a higher mode from an auxiliary oversized waveguide. The rods of the optimum structure have the elongated form of the cross-section with the resonant length in the direction of wave propagation equal to a multiple of the half-wavelength of the fundamental mode of the hyperguide. This row of rods forms a multiinjection grill with zero phase shift between waveguides. The second row of rods supporting the constructive superposition of the incident and doubly reflected waves enhances the efficiency of the structure. The optimum structure has a power spectrum with narrow peaks (the main N || =-2.15 and the parasitic N || =3.15), low power reflection (R tot =15%), high coupled power directivity (δ CP =70%), reasonable N || -weighted directivity (|δ CD w |=35%) and the peaking factor on the electric field equal to 3. Based on the optimization it is possible to design parameters of a big structure with tens of rods. The number of the construction elements of the structure can be reduced 20 times compared with the standard multijunction array. (author) 14 figs., 22 refs

  19. Evaluation of stereoscopic video cameras synchronized with the movement of an operator's head on the teleoperation of the actual backhoe shovel

    Science.gov (United States)

    Minamoto, Masahiko; Matsunaga, Katsuya

    1999-05-01

    Operator performance while using a remote controlled backhoe shovel is described for three different stereoscopic viewing conditions: direct view, fixed stereoscopic cameras connected to a helmet mounted display (HMD), and rotating stereo camera connected and slaved to the head orientation of a free moving stereo HMD. Results showed that the head- slaved system provided the best performance.

  20. Femoral head avascular necrosis

    International Nuclear Information System (INIS)

    Chrysikopoulos, H.; Sartoris, D.J.; Resnick, D.L.; Ashburn, W.; Pretorius, T.

    1988-01-01

    MR imaging has been shown to be more sensitive and specific than planar scintigraphy for avascular necrosis (AVN) of the femoral head. However, experience with single photon emission CT (SPECT) is limited. The authors retrospectively compared 1.5-T MR imaging with SPECT in 14 patients with suspected femoral head AVN. Agreement between MR imaging and SPECT was present in 24 femurs, 14 normal and ten with AVN. MR imaging showed changes of AVN in the remaining four femoral heads. Of these, one was normal and the other three inconclusive for AVN by SPECT. The authors conclude that MR imaging is superior to SPECT for the evaluation of AVN of the hip

  1. Protective head of sensors

    International Nuclear Information System (INIS)

    Liska, K.; Anton, P.

    1987-01-01

    The discovery concerns the protective heads of diagnostic assemblies of nuclear power plants for conductors of the sensors from the fuel and control parts of the said assemblies. A detailed description is presented of the design of the protective head which, as compared with the previous design, allows quick and simple assembly with reduced risk of damaging the sensors. The protective head may be used for diagnostic assemblies both in power and in research reactors and it will be used for WWER reactor assemblies. (A.K.). 3 figs

  2. Methods and apparatus for radially compliant component mounting

    Science.gov (United States)

    Bulman, David Edward [Cincinnati, OH; Darkins, Jr., Toby George; Stumpf, James Anthony [Columbus, IN; Schroder, Mark S [Greenville, SC; Lipinski, John Joseph [Simpsonville, SC

    2012-03-27

    Methods and apparatus for a mounting assembly for a liner of a gas turbine engine combustor are provided. The combustor includes a combustor liner and a radially outer annular flow sleeve. The mounting assembly includes an inner ring surrounding a radially outer surface of the liner and including a plurality of axially extending fingers. The mounting assembly also includes a radially outer ring coupled to the inner ring through a plurality of spacers that extend radially from a radially outer surface of the inner ring to the outer ring.

  3. Determining the Position of Head and Shoulders in Neurological Practice with the use of Cameras

    Directory of Open Access Journals (Sweden)

    P. Kutílek

    2011-01-01

    Full Text Available The posture of the head and shoulders can be influenced negatively by many diseases of the nervous system, visual and vestibular systems. We have designed a system and a set of procedures for evaluating the inclination (roll, flexion (pitch and rotation (yaw of the head and the inclination (roll and rotation (yaw of the shoulders. A new computational algorithm allows non-invasive and non-contact head and shoulder position measurement using two cameras mounted opposite each other, and the displacement of the optical axis of the cameras is also corrected.

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  5. Exploding head syndrome.

    Science.gov (United States)

    Sharpless, Brian A

    2014-12-01

    Exploding head syndrome is characterized by the perception of abrupt, loud noises when going to sleep or waking up. They are usually painless, but associated with fear and distress. In spite of the fact that its characteristic symptomatology was first described approximately 150 y ago, exploding head syndrome has received relatively little empirical and clinical attention. Therefore, a comprehensive review of the scientific literature using Medline, PsycINFO, Google Scholar, and PubMed was undertaken. After first discussing the history, prevalence, and associated features, the available polysomnography data and five main etiological theories for exploding head syndrome are summarized. None of these theories has yet reached dominance in the field. Next, the various methods used to assess and treat exploding head syndrome are discussed, as well as the limited outcome data. Finally, recommendations for future measure construction, treatment options, and differential diagnosis are provided. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... medically necessary because of potential risk to the baby. This risk is, however, minimal with head CT ... intravenous contrast indicate mothers should not breastfeed their babies for 24-48 hours after contrast medium is ...

  7. Early Head Start Evaluation

    Data.gov (United States)

    U.S. Department of Health & Human Services — Longitudinal information from an evaluation where children were randomly assigned to Early Head Start or community services as usual;direct assessments and...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for ... Tomography (CT) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... head CT scanning. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... rays). top of page What are some common uses of the procedure? CT scanning of the head ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... rays). top of page What are some common uses of the procedure? CT scanning of the head ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  13. Head Start Impact Study

    Data.gov (United States)

    U.S. Department of Health & Human Services — Nationally representative, longitudinal information from an evaluation where children were randomly assigned to Head Start or community services as usual;direct...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  15. TCGA head Neck

    Science.gov (United States)

    Investigators with The Cancer Genome Atlas (TCGA) Research Network have discovered genomic differences – with potentially important clinical implications – in head and neck cancers caused by infection with the human papillomavirus (HPV).

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... your doctor to evaluate your face, sinuses, and skull or to plan radiation therapy for brain cancer. ... typically used to detect: bleeding, brain injury and skull fractures in patients with head injuries. bleeding caused ...

  17. PECULIARITIES OF ASSIGNMENT OF ROLLING BEARING MOUNTING AND PARAMETERS OF GEOMETRIC ACCURACY OF MOUNTING SURFACES OF SHAFTS AND FRAMES

    Directory of Open Access Journals (Sweden)

    Adamenko Yu. І.

    2017-04-01

    Full Text Available The standards and methods concerning assignment of rolling bearing fit with shafts and frames via example of bearing 6-208 are analyzed. We set certain differences of recommendations according to GOST 3325-85, "Rolling bearings. Tolerance zones and technical requirements to mounting surfaces of shafts and frames. Attachment" and by reference of rolling bearing manufacturers. The following factors should be taken into consideration when assigning the mounting with the tension the internal ring of the bearing with shaft and mounting with a gap in the outer ring with a housing bore. The methods of achieving accuracy of mounting surfaces of shafts and frames via form tolerance assignment: roundness tolerance, profile of longitudinal cut, cross section, cylindricity and others. It is possible to limit the bearing rings in different ways, for example appointing the cylindrical mounting surfaces and bead end surfaces the appropriate tolerances, namely: coaxiality tolerance or full radial beat of mounting surfaces, and also perpendicularity tolerance, butt beats and full butt beats of mounting end surfaces. We suggest to expand methods of achieving the accuracy of shafts and frames depending on seriation of production and production operations metrology support.

  18. The exploding head syndrome.

    Science.gov (United States)

    Green, M W

    2001-06-01

    This article reviews the features of an uncommon malady termed "the exploding head syndrome." Sufferers describe terrorizing attacks of a painless explosion within their head. Attacks tend to occur at the onset of sleep. The etiology of attacks is unknown, although they are considered to be benign. Treatment with clomipramine has been suggested, although most sufferers require only reassurance that the spells are benign in nature.

  19. GPK heading machine

    Energy Technology Data Exchange (ETDEWEB)

    Krmasek, J.; Novosad, K.

    1981-01-01

    This article evaluates performance tests of the Soviet made GPK heading machine carried out in 4 coal mines in Czechoslovakia (Ostrava-Karvina region and Kladno mines). GPK works in coal seams and rocks with compression strength of 40 to 50 MPa. Dimensions of the tunnel are height 1.8 to 3.8 m and width 2.6 to 4.7 m, tunnel gradient plus to minus 10 degrees. GPK weighs 16 t, its conical shaped cutting head equipped with RKS-1 cutting tools is driven by an electric motor with 55 kW capacity. Undercarriage of the GPK, gathering-arm loader, hydraulic system, electric system and dust supression system (water spraying or pneumatic section) are characterized. Specifications of GPK heading machines are compared with PK-3r and F8 heading machines. Reliability, number of failures, dust level, noise, productivity depending on compression strength of rocks, heading rate in coal and in rocks, energy consumption, performance in inclined tunnels, and cutting tool wear are evaluated. Tests show that GPK can be used to drive tunnels in coal with rock constituting up to 50% of the tunnel crosscut, as long as rock compression strength does not exceed 50 MPa. In rocks characterized by higher compression strength cutting tool wear sharply increases. GPK is characterized by higher productivity than that of the PK-3r heading machine. Among the weak points of the GPK are: unsatisfactory reliability and excessive wear of its elements. (4 refs.) (In Czech)

  20. Mechanical Design of an Omni-Directional Sensor Mount

    National Research Council Canada - National Science Library

    Rosheim, Mark

    2002-01-01

    This effort has been directed to development and demonstration of a gimbal mount capable of 180 degree singularity- free pitch and yaw motion about a two-axis center, avoiding the common problem of gimbal lock...

  1. Rapid mounting of adult Drosophila structures in Hoyer's medium.

    Science.gov (United States)

    Stern, David L; Sucena, Elio

    2012-01-01

    The Drosophila cuticle carries a rich array of morphological details. Thus, cuticle examination has had a central role in the history of genetics. This protocol describes a procedure for mounting adult cuticles in Hoyer's medium, a useful mountant for both larval and adult cuticles. The medium digests soft tissues rapidly, leaving the cuticle cleared for observation. In addition, samples can be transferred directly from water to Hoyer's medium. However, specimens mounted in Hoyer's medium degrade over time. For example, the fine denticles on the larval dorsum are best observed soon after mounting; they begin to fade after 1 week, and can disappear completely after several months. More robust features, such as the ventral denticle belts, will persist for a longer period of time. Because adults cannot profitably be mounted whole in Hoyer's medium, some dissection is necessary.

  2. Application of Evolutionary Computation in Automotive Powertrain Mount Tuning

    Directory of Open Access Journals (Sweden)

    Anab Akanda

    2006-01-01

    Full Text Available Engine mount tuning is a multi-disciplinary exercise since it affects Idle-shake, Road-shake and power-train noise response. Engine inertia is often used as a tuned absorber for controlling suspension resonance related road-shake issues. Last but not least, vehicle ride and handling may also be affected by mount tuning. In this work, Torque-Roll-Axis (TRA decoupling of the rigid powertrain was used as a starting point for mount tuning. Nodal point of flexible powertrain bending was used to define the envelop for transmission mount locations. The frequency corresponding to the decoupled roll mode of the rigid powertrain was then adjusted for idle-shake and road-shake response management.

  3. A vehicle mounted scintillation ratemeter for environmental survey

    International Nuclear Information System (INIS)

    Cavell, I.W.

    1960-01-01

    An improved method of mounting an existing environmental gamma survey equipment in a vehicle is described. Performance data for the equipment is given and some typical radiometric traces obtained at A.E.E. Winfrith given. (author)

  4. Low radioactivity material for use in mounting radiation detectors

    Science.gov (United States)

    Fong, Marshall; Metzger, Albert E.; Fox, Richard L.

    1988-01-01

    Two materials, sapphire and synthetic quartz, have been found for use in Ge detector mounting assemblies. These materials combine desirable mechanical, thermal, and electrical properties with the radioactive cleanliness required to detect minimal amounts of K, Th, and U.

  5. How Mount Stromlo Observatory shed its imperial beginnings

    Science.gov (United States)

    Bhathal, Ragbir

    2014-12-01

    In the 90 years since its foundation in 1924, Mount Stromlo Observatory in Australia has changed from an outpost of empire to an international research institution. Ragbir Bhathal examines how the British influence waxed and waned.

  6. Fathead minnow whole-mount in situ hybridization (WISH)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This study demonstrates the potential of whole-mount in situ hybridization (WISH), in conjunction with quantitative real-time polymerase chain reaction (QPCR)...

  7. A Surface-Mounted Rotor State Sensing System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A surface-mounted instrumentation system for measuring rotor blade motions on rotorcraft, for use both in flight and in wind tunnel testing, is proposed for...

  8. Taking Charge: Walter Sydney Adams and the Mount Wilson Observatory

    Science.gov (United States)

    Brashear, R.

    2004-12-01

    The growing preeminence of American observational astronomy in the first half of the 20th century is a well-known story and much credit is given to George Ellery Hale and his skill as an observatory-building entrepreneur. But a key figure who has yet to be discussed in great detail is Walter Sydney Adams (1876-1956), Hale's Assistant Director at Mount Wilson Observatory. Due to Hale's illnesses, Adams was Acting Director for much of Hale's tenure, and he became the second Director of Mount Wilson from 1923 to 1946. Behind his New England reserve Adams was instrumental in the growth of Mount Wilson and thus American astronomy in general. Adams was hand-picked by Hale to take charge of stellar spectroscopy work at Yerkes and Mount Wilson and the younger astronomer showed tremendous loyalty to Hale and Hale's vision throughout his career. As Adams assumed the leadership role at Mount Wilson he concentrated on making the observatory a place where researchers worked with great freedom but maintain a high level of cooperation. This paper will concentrate on Adams's early years and look at his growing relationship with Hale and how he came to be the central figure in the early history of Mount Wilson as both a solar and stellar observatory. His education, his years at Dartmouth and Yerkes (including his unfortunate encounter with epsilon Leonis), and his formative years on Mount Wilson are all important in learning how he shaped the direction of Mount Wilson and the development of American astronomy in the first half of the 20th century. This latter history cannot be complete until we bring Adams into better focus.

  9. Some technical solutions on organization and technology of reactor room component mounting

    International Nuclear Information System (INIS)

    Romanovskij, V.I.

    1982-01-01

    Design of the production equipment for mounting sites of heat facilities of the Zaporozhe NPP is considered. Plan of the production equipment for mounting sites of heat facilities and flowsheet of mounting of supporting truss of the reactor are presented

  10. National Ingition Facility subsystem design requirements optical mounts SSDR 1.4.4

    International Nuclear Information System (INIS)

    Richardson, M.

    1996-01-01

    This SSDR establishes the performance, design, development and test requirements for NIF Beam Transport Optomechanical Subsystems. optomechanical Subsystems includes the mounts for the beam transport mirrors, LMl - LM8, the polarizer mount, and the spatial filter lens mounts

  11. Dissection and Flat-mounting of the Threespine Stickleback Branchial Skeleton.

    Science.gov (United States)

    Ellis, Nicholas A; Miller, Craig T

    2016-05-07

    The posterior pharyngeal segments of the vertebrate head give rise to the branchial skeleton, the primary site of food processing in fish. The morphology of the fish branchial skeleton is matched to a species' diet. Threespine stickleback fish (Gasterosteus aculeatus) have emerged as a model system to study the genetic and developmental basis of evolved differences in a variety of traits. Marine populations of sticklebacks have repeatedly colonized countless new freshwater lakes and creeks. Adaptation to the new diet in these freshwater environments likely underlies a series of craniofacial changes that have evolved repeatedly in independently derived freshwater populations. These include three major patterning changes to the branchial skeleton: reductions in the number and length of gill raker bones, increases in pharyngeal tooth number, and increased branchial bone lengths. Here we describe a detailed protocol to dissect and flat-mount the internal branchial skeleton in threespine stickleback fish. Dissection of the entire three-dimensional branchial skeleton and mounting it flat into a largely two-dimensional prep allows for the easy visualization and quantification of branchial skeleton morphology. This dissection method is inexpensive, fast, relatively easy, and applicable to a wide variety of fish species. In sticklebacks, this efficient method allows the quantification of skeletal morphology in genetic crosses to map genomic regions controlling craniofacial patterning.

  12. New active machine tool drive mounting on the frame

    Directory of Open Access Journals (Sweden)

    Švéda J.

    2007-10-01

    Full Text Available The paper deals with the new active mounting of the machine tool drives. The commonly used machine tools are at this time mainly equipped with fix-mounting of the feed drives. This structure causes full transmission of the force shocks to the machine bed and thereby restricts the dynamic properties of the motion axis and the whole machine. The spring-mounting of the feed drives is one of the possibilities how to partially suppress the vibrations. The force that reacts to the machine tool bed is transformed thereby the vibrations are lightly reduced. Unfortunately the transformation is not fully controlled. The new active mounting of the machine tool drives allows to fully control the force behaviour that react to the machine body. Thereby the number of excited frequencies on the machine tool bed is significantly reduced. The active variant of the feed drive mounting is characterized by the synergistic cooperation between two series-connected actuators (“motor on motor”. The paper briefly describes design, control techniques and optimization of the feed drives with the new active mounting conception.

  13. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  15. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  16. Head, Neck, and Oral Cancer

    Science.gov (United States)

    ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  17. Penguin head movement detected using small accelerometers: a proxy of prey encounter rate.

    Science.gov (United States)

    Kokubun, Nobuo; Kim, Jeong-Hoon; Shin, Hyoung-Chul; Naito, Yasuhiko; Takahashi, Akinori

    2011-11-15

    Determining temporal and spatial variation in feeding rates is essential for understanding the relationship between habitat features and the foraging behavior of top predators. In this study we examined the utility of head movement as a proxy of prey encounter rates in medium-sized Antarctic penguins, under the presumption that the birds should move their heads actively when they encounter and peck prey. A field study of free-ranging chinstrap and gentoo penguins was conducted at King George Island, Antarctica. Head movement was recorded using small accelerometers attached to the head, with simultaneous monitoring for prey encounter or body angle. The main prey was Antarctic krill (>99% in wet mass) for both species. Penguin head movement coincided with a slow change in body angle during dives. Active head movements were extracted using a high-pass filter (5 Hz acceleration signals) and the remaining acceleration peaks (higher than a threshold acceleration of 1.0 g) were counted. The timing of head movements coincided well with images of prey taken from the back-mounted cameras: head movement was recorded within ±2.5 s of a prey image on 89.1±16.1% (N=7 trips) of images. The number of head movements varied largely among dive bouts, suggesting large temporal variations in prey encounter rates. Our results show that head movement is an effective proxy of prey encounter, and we suggest that the method will be widely applicable for a variety of predators.

  18. Do the radial head prosthesis components fit with the anatomical structures of the proximal radioulnar joint?

    Science.gov (United States)

    Wegmann, Kilian; Hain, Moritz K; Ries, Christian; Neiss, Wolfram F; Müller, Lars P; Burkhart, Klaus J

    2015-09-01

    The fitting accuracy of radial head components has been investigated in the capitulo-radial joint, and reduced contact after prosthetic replacement of the radial head has been observed. The kinematics of the proximal radioulnar joint (PRUJ) are affected by radial head arthroplasty as well, but have not yet been investigated in this regard. The elbow joints of 60 upper extremities of formalin-fixed body donors were disarticulated to obtain a good view of the PRUJ. Each specimen was mounted on the examining table and radial head position in the native PRUJ was assessed in neutral position, full pronation, and full supination. Measurements were repeated after implantation of mono- and bi-polar prostheses. Analysis of the distribution of the joint contacts in the compartments showed significant differences after radial head replacement. In comparison to the native joint, after bipolar and monopolar radial head replacement, the physiological shift of the proximal radius was altered. The physiological shift of the joint contact of the radial head from anterior to posterior during forearm rotation that was found in the native joint in our cadaver model was not observed after prosthetic replacement. With higher conformity and physiological kinematic of radial head prostheses, possibly lower shear forces and lower contact pressures would be generated. The tested radial head prostheses do not replicate the physiological kinematics of the radial head. Further development in the prosthesis design has to be made. The meticulous reconstruction of the annular ligament seems to be of importance to increase joint contact.

  19. Comparison between skin-mounted fiducials and bone-implanted fiducials for image-guided neurosurgery

    Science.gov (United States)

    Rost, Jennifer; Harris, Steven S.; Stefansic, James D.; Sillay, Karl; Galloway, Robert L., Jr.

    2004-05-01

    Point-based registration for image-guided neurosurgery has become the industry standard. While the use of intrinsic points is appealing because of its retrospective nature, affixing extrinsic objects to the head prior to scanning has been demonstrated to provide much more accurate registrations. Points of reference between image space and physical space are called fiducials. The extrinsic objects which generate those points are fiducial markers. The markers can be broken down into two classifications: skin-mounted and bone-implanted. Each has distinct advantages and disadvantages. Skin-mounted fiducials require simply sticking them on the patient in locations suggested by the manufacturer, however, they can move with tractions placed on the skin, fall off and perhaps the most dangerous problem, they can be replaced by the patient. Bone implanted markers being rigidly affixed to the skull do not present such problems. However, a minor surgical intervention (analogous to dental work) must be performed to implant the markers prior to surgery. Therefore marker type and use has become a decision point for image-guided surgery. We have performed a series of experiments in an attempt to better quantify aspects of the two types of markers so that better informed decisions can be made. We have created a phantom composed of a full-size plastic skull [Wards Scientific Supply] with a 500 ml bag of saline placed in the brain cavity. The skull was then sealed. A skin mimicking material, DragonSkinTM [SmoothOn Company] was painted onto the surface and allowed to dry. Skin mounted fiducials [Medtronic-SNT] and bone-implanted markers [Z-Kat]were placed on the phantom. In addition, three additional bone-implanted markers were placed (two on the base of the skull and one in the eye socket for use as targets). The markers were imaged in CT and 4 MRI sequences (T1-weighted, T2 weighted, SPGR, and a functional series.) The markers were also located in physical space using an Optotrak

  20. UHV mirror mounts for photophysics beamline at Indus-I

    International Nuclear Information System (INIS)

    Meenakshi Raja Rao, P.; Bhattacharya, S.S.; Das, N.C.; Rajasekhar, B.N.; Roy, A.P.

    1995-01-01

    Photophysics beamline makes use of a combination of two toroidal mirrors and one meter Seya-Namioka Monochromator in its fore optics. The fore optics monochromatises and steers the synchrotron radiation source (SRS) beam from its tangent point to the sample situated at a distance of about five meters. Slit widths of the monochromator are of the order of 100μ and the sample size is one mm 2 . Hence it is essential to impart precision rotational and translational movements of the same order of magnitude to the mirrors with the use of appropriate mirror mounts. Since Indus-1 operates at a pressure -9 mbar, the mirror mounts should be UHV compatible and the movements should be actuated under UHV. The mirrors along with the mirror mounts are enclosed in UHV chambers. The mirror chambers have been fabricated at Centre for Advanced Technology (CAT) workshops and tested up to a pressure of 10 -9 mbar. The mirror mounts are designed, fabricated and leak checked (He leak rate -10 std cc/s) The precision movements are achieved with the help of bellow sealed shaft mechanism and adjustable screws provided with the kinematic mount of the mirror frame. The performance of the mirror mount was tested at atmospheric pressure by using a laser beam and found to be good. The minimum displacement of the laser beam at slit and sample positions is ∼ 70μ which is quite adequate for optical alignment. The performance of the mirror mount under UHV conditions is being evaluated. (author). 4 refs., 3 figs

  1. Head first Ajax

    CERN Document Server

    Riordan, Rebecca M

    2008-01-01

    Ajax is no longer an experimental approach to website development, but the key to building browser-based applications that form the cornerstone of Web 2.0. Head First Ajax gives you an up-to-date perspective that lets you see exactly what you can do -- and has been done -- with Ajax. With it, you get a highly practical, in-depth, and mature view of what is now a mature development approach. Using the unique and highly effective visual format that has turned Head First titles into runaway bestsellers, this book offers a big picture overview to introduce Ajax, and then explores the use of ind

  2. Head First Statistics

    CERN Document Server

    Griffiths, Dawn

    2009-01-01

    Wouldn't it be great if there were a statistics book that made histograms, probability distributions, and chi square analysis more enjoyable than going to the dentist? Head First Statistics brings this typically dry subject to life, teaching you everything you want and need to know about statistics through engaging, interactive, and thought-provoking material, full of puzzles, stories, quizzes, visual aids, and real-world examples. Whether you're a student, a professional, or just curious about statistical analysis, Head First's brain-friendly formula helps you get a firm grasp of statistics

  3. Mounting ground sections of teeth: Cyanoacrylate adhesive versus Canada balsam.

    Science.gov (United States)

    Vangala, Manogna Rl; Rudraraju, Amrutha; Subramanyam, R V

    2016-01-01

    Hard tissues can be studied by either decalcification or by preparing ground sections. Various mounting media have been tried and used for ground sections of teeth. However, there are very few studies on the use of cyanoacrylate adhesive as a mounting medium. The aim of our study was to evaluate the efficacy of cyanoacrylate adhesive (Fevikwik™) as a mounting medium for ground sections of teeth and to compare these ground sections with those mounted with Canada balsam. Ground sections were prepared from twenty extracted teeth. Each section was divided into two halves and mounted on one slide, one with cyanoacrylate adhesive (Fevikwik™) and the other with Canada balsam. Scoring for various features in the ground sections was done by two independent observers. Statistical analysis using Student's t-test (unpaired) of average scores was performed for each feature observed. No statistically significant difference was found between the two for most of the features. However, cyanoacrylate was found to be better than Canada balsam for observing striae of Retzius (P < 0.0205), enamel lamellae (P < 0.036), dentinal tubules (P < 0.0057), interglobular dentin (P < 0.0001), sclerotic dentin - transmitted light (P < 0.00001), sclerotic dentin - polarized light (P < 0.0002) and Sharpey's fibers (P < 0.0004). This initial study shows that cyanoacrylate is better than Canada balsam for observing certain features of ground sections of teeth. However, it remains to be seen whether it will be useful for studying undecalcified sections of carious teeth and for soft tissue sections.

  4. Mirror boxes and mirror mounts for photophysics beamline

    International Nuclear Information System (INIS)

    Raja Rao, P.M.; Raja Sekhar, B.N.; Das, N.C.; Khan, H.A.; Bhattacharya, S.S.; Roy, A.P.

    1996-01-01

    Photophysics beamline makes use of one metre Seya-Namioka monochromator and two toroidal mirrors in its fore optics. The first toroidal mirror (pre mirror) focuses light originating from the tangent point of the storage ring onto the entrance slit of the monochromator and second toroidal mirror (post mirror) collects light from the exit slit of the monochromator and focuses light onto the sample placed at a distance of about one metre away from the 2nd mirror. To steer light through monochromator and to focus it on the sample of 1mm x 1mm size require precision rotational and translational motion of the mirrors and this has been achieved with the help of precision mirror mounts. Since Indus-1 operates at pressures less than 10 -9 m.bar, the mirror mounts should be manipulated under similar ultra high vacuum conditions. Considering these requirements, two mirror boxes and two mirror mounts have been designed and fabricated. The coarse movements to the mirrors are imparted from outside the mirror chamber with the help of x-y tables and precision movements to the mirrors are achieved with the help of mirror mounts. The UHV compatibility and performance of the mirror mounts connected to mirror boxes under ultra high vacuum condition is evaluated. The details of the design, fabrication and performance evaluation are discussed in this report. 5 refs., 9 figs., 1 tab

  5. Multi-Mounted X-Ray Computed Tomography.

    Science.gov (United States)

    Fu, Jian; Liu, Zhenzhong; Wang, Jingzheng

    2016-01-01

    Most existing X-ray computed tomography (CT) techniques work in single-mounted mode and need to scan the inspected objects one by one. It is time-consuming and not acceptable for the inspection in a large scale. In this paper, we report a multi-mounted CT method and its first engineering implementation. It consists of a multi-mounted scanning geometry and the corresponding algebraic iterative reconstruction algorithm. This approach permits the CT rotation scanning of multiple objects simultaneously without the increase of penetration thickness and the signal crosstalk. Compared with the conventional single-mounted methods, it has the potential to improve the imaging efficiency and suppress the artifacts from the beam hardening and the scatter. This work comprises a numerical study of the method and its experimental verification using a dataset measured with a developed multi-mounted X-ray CT prototype system. We believe that this technique is of particular interest for pushing the engineering applications of X-ray CT.

  6. Silva as the Head

    DEFF Research Database (Denmark)

    Svabo, Connie

    2015-01-01

    The head of the performance design programme is substituted by a sister's academy delegate. this performance situation formed part of a week of semesterstart where the students and professors visited Sister's Academy, Malmø. I participated in the Sister's Academy as visiting researcher and here i...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... are present in the paranasal sinuses. plan radiation therapy for cancer of the brain or other tissues. guide the ... RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association top ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography ( ...

  10. The Twente humanoid head

    NARCIS (Netherlands)

    Reilink, Rob; Visser, L.C.; Bennik, J.; Carloni, Raffaella; Brouwer, Dannis Michel; Stramigioli, Stefano

    2009-01-01

    This video shows the results of the project on the mechatronic development of the Twente humanoid head. The mechanical structure consists of a neck with four degrees of freedom (DOFs) and two eyes (a stereo pair system) which tilt on a common axis and rotate sideways freely providing a three more

  11. Get a head in telepresence: active vision for remote intervention

    International Nuclear Information System (INIS)

    Pretlove, J.

    1996-01-01

    Despite advances in robotic systems, many tasks needing to be undertaken in hazardous environments require human control. The risk to human life can be reduced or minimised using an integrated control system comprising an active controllable stereo vision system and a virtual reality head-mounted display. The human operator is then immersed in and can interact with the remote environment in complete safety. An overview is presented of the design and development of just such an advanced, dynamic telepresence system, developed at the Department of Mechanical Engineering at the University of Surrey. (UK)

  12. Analysis of real-time head accelerations in collegiate football players.

    Science.gov (United States)

    Duma, Stefan M; Manoogian, Sarah J; Bussone, William R; Brolinson, P Gunnar; Goforth, Mike W; Donnenwerth, Jesse J; Greenwald, Richard M; Chu, Jeffrey J; Crisco, Joseph J

    2005-01-01

    To measure and analyze head accelerations during American collegiate football practices and games. A newly developed in-helmet 6-accelerometer system that transmits data via radio frequency to a sideline receiver and laptop computer system was implemented. From the data transfer of these accelerometer traces, the sideline staff has real-time data including the head acceleration, the head injury criteria value, the severity index value, and the impact location. Data are presented for instrumented players for the entire 2003 football season, including practices and games. American collegiate football. Thirty-eight players from Virginia Tech's varsity football team. Accelerations and pathomechanics of head impacts. : A total of 3312 impacts were recorded over 35 practices and 10 games for 38 players. The average peak head acceleration, Gadd Severity Index, and Head Injury Criteria were 32 g +/- 25 g, 36 g +/- 91 g, and 26 g +/- 64 g, respectively. One concussive event was observed with a peak acceleration of 81 g, a 267 Gadd Severity Index, and 200 Head Injury Criteria. Because the concussion was not reported until the day after of the event, a retrospective diagnosis based on his history and clinical evaluation suggested a mild concussion. The primary finding of this study is that the helmet-mounted accelerometer system proved effective at collecting thousands of head impact events and providing contemporaneous head impact parameters that can be integrated with existing clinical evaluation techniques.

  13. Inverse axial mounting stiffness design for lithographic projection lenses.

    Science.gov (United States)

    Wen-quan, Yuan; Hong-bo, Shang; Wei, Zhang

    2014-09-01

    In order to balance axial mounting stiffness of lithographic projection lenses and the image quality under dynamic working conditions, an easy inverse axial mounting stiffness design method is developed in this article. Imaging quality deterioration at the wafer under different axial vibration levels is analyzed. The desired image quality can be determined according to practical requirements, and axial vibrational tolerance of each lens is solved with the damped least-squares method. Based on adaptive interval adjustment, a binary search algorithm, and the finite element method, the axial mounting stiffness of each lens can be traveled in a large interval, and converges to a moderate numerical solution which makes the axial vibrational amplitude of the lens converge to its axial vibrational tolerance. Model simulation is carried out to validate the effectiveness of the method.

  14. Preparation and mounting of adult Drosophila structures in Canada balsam.

    Science.gov (United States)

    Stern, David L; Sucena, Elio

    2012-03-01

    The Drosophila cuticle carries a rich array of morphological details. Thus, cuticle examination has had a central role in the history of genetics. To prepare fine "museum-quality," permanent slides, it is best to mount specimens in Canada Balsam. It is difficult to give precise recipes for Canada Balsam, because every user seems to prefer a slightly different viscosity. Dilute solutions spread easily and do not dry too rapidly while mounting specimens. The disadvantage is that there is actually less Balsam in a "drop" of the solution, and when dried, it can contract from the sides of the coverslip, sometimes disturbing the specimen. Unfortunately, there is no substitute for experience when using Canada Balsam. This protocol describes a procedure for mounting adult cuticles in Canada Balsam.

  15. Solar rotation measurements at Mount Wilson. Pt. 2

    International Nuclear Information System (INIS)

    Labonte, B.J.; Howard, R.; Carnegie Institution of Washington, Pasadena

    1981-01-01

    Possible sources of systematic error in solar Doppler rotational velocities are examined. Scattered light is shown to affect the Mount Wilson solar rotation results, but this effect is not enough to bring the spectroscopic results in coincidence with the sunspot rotation. Interference fringes at the spectrograph focus at Mount Wilson have in two intervals affected the rotation results. It has been possible to correlate this error with temperature and thus correct for it. A misalignment between the entrance and exit slits is a possible source of error, but for the Mount Wilson slit configuration the amplitude of this effect is negligibly small. Rapid scanning of the solar image also produces no measurable effect. (orig.)

  16. Linear and/or curvilinear rail mount system

    Science.gov (United States)

    Thomas, Jackie D. (Inventor); Harris, Lawanna L. (Inventor)

    2012-01-01

    One or more linear and/or curvilinear mounting rails are coupled to a structure. Each mounting rail defines a channel and at least one cartridge assembly is engaged in the channel. Each cartridge assembly includes a housing that slides within the channel. The housing defines a curvilinearly-shaped recess longitudinally aligned with the channel when the housing is in engagement therewith. The cartridge assembly also includes a cleat fitted in the recess for sliding engagement therealong. The cleat can be coupled to a fastener that passes through the mounting rail and the housing when the housing is so-engaged in the channel. The cleat is positioned in the recess by a position of the fastener.

  17. Head injury in children

    International Nuclear Information System (INIS)

    Sugiura, Makoto; Mori, Nobuhiko; Yokosuka, Reiko; Yamamoto, Masaaki; Imanaga, Hirohisa

    1981-01-01

    Findings of computerized tomography (CT) in 183 cases of head injury in children were investigated with special reference to CT findings of mild head injury. As was expected, CT findings of mild head injury fell within the normal range, in almost all cases. However, abnormal findings were noticed in 4 out of 34 cases (12%) in acute stage and 7 out of 76 cases (9%) in chronic stage. They were 3 cases of localized low density area in acute stage and 6 cases of mild cerebral atrophy in chronic stage, etc. There were some cases of mild head injury in which CT findings were normal while EEG examination revealed abnormality. Also in some cases, x-ray study demonstrated linear skull fracture which CT failed to show. These conventional techniques could be still remained as useful adjunct aid in diagnosis of head injury. CT findings of cases of cerebral contusion in their acute stage were divided as follows; normal, low density, small ventricle and ventricular and/or cisternal hemorrhage, frequency of incidence being 38, 17, 22, 11% respectively. These findings were invariably converted to cerebral atrophy from 10 days to 2 months after the impacts. In the cases with intracranial hematoma revealed by CT, only 32% of them showed clinical signs of Araki's type IV in their acute stage and 63% of them showed no neurological defects, that is Araki's type I and II. A case of extreme diffuse cerebral atrophy which followed acute subdural hematoma caused by tear of bridging veins without cortical contusion was presented. (author)

  18. The Status and Inspection of Bottom Mounted Instrumentation Nozzle in Korea

    International Nuclear Information System (INIS)

    Doh, Euisoon; Kim, Yoonwon; Kim, Jaeyoon; Lee, Tacksu; Lee, Changhun

    2012-01-01

    The PWSCC Cracking of Alloy 600 material has been issued since CRDM Penetration cracking of Bugey in France in 1990's. And J-groove weld cracking of CRDM at Oconee and PCR Nozzle cracking at Wolf Creek in USA were raising concern of the integrity for Dissimilar Metal Weld of Alloy 600. BMI(Bottom Mounted Instrumentation) Nozzle cracks were found at Takahama unit 1 in Japan and South Texas Project unit 1 in USA in 2003. And recent cracks of Reactor Head Vent line at Yonggwang unit 3 in Korea are enough to cause worry about the integrity for BMI Nozzles in Korea. BMI inspections of Westinghouse type plant were performed by KPS for Kori unit 1 in 2006, Ulchin unit 2 in 2007, and Kori unit 3 in 2008. The first inspection of OCR-1000 plant was carried out on May 2011 at Yonggwang unit 3. KPS developed the inspection technique of OCR-1000 plant for End Effector Module and controller, a quarterly actual sized Bottom head Mock up, Inspection probes meeting the regulatory guide lines and typical configuration of OCR-1000 plant. Two specimens with actual PWSCC cracks were used to demonstrate the Inspection technique of Detection and Sizing. and the quarterly actual sized Bottom head Mock up was very meaningful to check the Interference during the inspection by narrow gap between newly developments led to a successful inspection of the BMI Inspection. And the inspection was concurrently performed with 10 year Reactor Vessel ICI without hurting any critical path of the outage. This BMI inspection is contributing to keep Operational Safety of plants by prevention of Leakage at BMI nozzle and weld. And performing 10 Year ISI for BMI nozzle is very effective to prevent BMI nozzle Break by detecting PWSCC Initiation per PFM Sensitivity study

  19. Square Van Atta reflector with conducting mounting flame

    DEFF Research Database (Denmark)

    Nielsen, Erik Dragø

    1970-01-01

    A theoretical and numerical analysis of square Van Atta reflectors has been carried out with or without a conducting plate, used for mounting of the antenna elements. The Van Atta reflector investigated has antenna elements which are parallel half-wave dipoles interconnected in pairs by transmiss......A theoretical and numerical analysis of square Van Atta reflectors has been carried out with or without a conducting plate, used for mounting of the antenna elements. The Van Atta reflector investigated has antenna elements which are parallel half-wave dipoles interconnected in pairs...

  20. Experimental study of some mounting brackets to support fuel elements

    International Nuclear Information System (INIS)

    Aubert, M.; Poglia, S.; Roche, R.

    1958-09-01

    In an atomic pile with vertical channels, fuel elements are stacked on one another. According to a possible assembly, fuel element can be contained by a graphite sleeve and be supported by a mounting bracket in this sleeve. Sleeves are then stacked on one another. The authors report the investigation of different designs for these mounting brackets. They describe their mechanical role and their mechanical, aerodynamic, neutronic and test conditions. They report tests performed on brackets made in graphite and on brackets made in stainless steel and graphite, and discuss the obtained results

  1. Geology of the Ugashik-Mount Peulik Volcanic Center, Alaska

    Science.gov (United States)

    Miller, Thomas P.

    2004-01-01

    The Ugashik-Mount Peulik volcanic center, 550 km southwest of Anchorage on the Alaska Peninsula, consists of the late Quaternary 5-km-wide Ugashik caldera and the stratovolcano Mount Peulik built on the north flank of Ugashik. The center has been the site of explosive volcanism including a caldera-forming eruption and post-caldera dome-destructive activity. Mount Peulik has been formed entirely in Holocene time and erupted in 1814 and 1845. A large lava dome occupies the summit crater, which is breached to the west. A smaller dome is perched high on the southeast flank of the cone. Pyroclastic-flow deposits form aprons below both domes. One or more sector-collapse events occurred early in the formation of Mount Peulik volcano resulting in a large area of debris-avalanche deposits on the volcano's northwest flank. The Ugashik-Mount Peulik center is a calcalkaline suite of basalt, andesite, dacite, and rhyolite, ranging in SiO2 content from 51 to 72 percent. The Ugashik-Mount Peulik magmas appear to be co-genetic in a broad sense and their compositional variation has probably resulted from a combination of fractional crystallization and magma-mixing. The most likely scenario for a future eruption is that one or more of the summit domes on Mount Peulik are destroyed as new magma rises to the surface. Debris avalanches and pyroclastic flows may then move down the west and, less likely, east flanks of the volcano for distances of 10 km or more. A new lava dome or series of domes would be expected to form either during or within some few years after the explosive disruption of the previous dome. This cycle of dome disruption, pyroclastic flow generation, and new dome formation could be repeated several times in a single eruption. The volcano poses little direct threat to human population as the area is sparsely populated. The most serious hazard is the effect of airborne volcanic ash on aircraft since Mount Peulik sits astride heavily traveled air routes connecting the U

  2. Mount Sinai Hospital's approach to Ontario's Health System Funding Reform.

    Science.gov (United States)

    Chalk, Tyler; Lau, Davina; Morgan, Matthew; Dietrich, Sandra; Beduz, Mary Agnes; Bell, Chaim M

    2014-01-01

    In April 2012, the Ontario government introduced Health System Funding Reform (HSFR), a transformational shift in how hospitals are funded. Mount Sinai Hospital recognized that moving from global funding to a "patient-based" model would have substantial operational and clinical implications. Adjusting to the new funding environment was set as a top corporate priority, serving as the strategic basis for re-examining and redesigning operations to further improve both quality and efficiency. Two years into HSFR, this article outlines Mount Sinai Hospital's approach and highlights key lessons learned. Copyright © 2014 Longwoods Publishing.

  3. [Does the mounting of gastrointestinal biopsies on millipore filter contribute to an improved section quality?

    DEFF Research Database (Denmark)

    Asmussen, L.; Bernstein, I.; Matzen, P.

    2009-01-01

    orientation, GIB is occasionally mounted on millipore filter (MF) in an attempt to place the deep cut side onto the MF. The importance of this technique for section quality is evaluated in this study. MATERIAL AND METHOD: The material comprised three consecutive series of GIB (60 gastric, duodenal......, and colorectal GIB, respectively). Sections were grouped in MF-mounted versus non-mounted GIB, the proportion of fully acceptable sections among mounted versus non-mounted GIB was recorded. RESULTS: 77.2% of all GIBs were MF-mounted. 33.1% of mounted GIBs versus 48.8% of non-mounted GIBs were assessed as fully...... acceptable sections. The differences between these figures are not statistically significant. 41.7% of the mounted GIBs were placed with the mucosal surface facing the MF, which entails a risk of damaging the tissue. CONCLUSION: MF-mounting of GIB did not contribute to section quality. Since the handling...

  4. Head-coupled remote stereoscopic camera system for telepresence applications

    Science.gov (United States)

    Bolas, Mark T.; Fisher, Scott S.

    1990-09-01

    The Virtual Environment Workstation Project (VIEW) at NASA's Ames Research Center has developed a remotely controlled stereoscopic camera system that can be used for telepresence research and as a tool to develop and evaluate configurations for head-coupled visual systems associated with space station telerobots and remote manipulation robotic arms. The prototype camera system consists of two lightweight CCD video cameras mounted on a computer controlled platform that provides real-time pan, tilt, and roll control of the camera system in coordination with head position transmitted from the user. This paper provides an overall system description focused on the design and implementation of the camera and platform hardware configuration and the development of control software. Results of preliminary performance evaluations are reported with emphasis on engineering and mechanical design issues and discussion of related psychophysiological effects and objectives.

  5. Head and Neck Cancer Treatment

    Science.gov (United States)

    ... Professions Site Index A-Z Head and Neck Cancer Treatment Head and neck cancer overview What are my ... and neck cancer. For updated information on new cancer treatments that are available, you should discuss these issues ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association ... MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  8. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed with ... and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed with ...

  9. Head Lice: Prevention and Control

    Science.gov (United States)

    ... and General Public. Contact Us Parasites Home Prevention & Control Language: English (US) Español (Spanish) Recommend on Facebook ... that can be taken to help prevent and control the spread of head lice: Avoid head-to- ...

  10. MRI in head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin Kyo [Shin Wha Hospital, Seoul (Korea, Republic of)

    1986-02-15

    In the diagnosis of head injury, Magnetic Resonance Imaging (MRI), like CT, is an effective method of distinguishing between intracerebral and extracerebral lesions. In our experience of MRI, early hematomas are almost isointense by Saturation Recovery (SR) method, so these must be performed with Spin Echo (SE) method for better visualization of hematomas. Isodense subdural hematomas, which is a diagnostic dilemma on CT images, are clearly seen on MRI. Delayed hematomas or residual parenchymal lesions are better demonstrated on MRI than on CT. Direct cornal, sagittal images and multiplanar facility of MRI provides excellent visualization of the the location and shape of extracerebral collection of hematoma. For the screening of head traumas, SE method is a technique of choice because of its excellent sensitivity within limited time.

  11. Where is Russia heading?

    Directory of Open Access Journals (Sweden)

    Natalija Pliskevič

    1999-10-01

    Full Text Available The author examines the proceedings from the collection Where is Russia Heading? (= Куда идёт Россия?, published between 1994 and 1998 in connection with the international symposium held under this name each year in Moscow. The symposia and their proceeding, involving leading Russian and foreign experts, were significant in that they encompassed a wide range of themes – social, economic, political, legislative, cultural and other transformations that have been occurring in Russia during the past decades. The author, however, limits her review to contributions dealing with ethno-political and socio-cultural transformations in Russia. She concludes that the question – “Where is Russia heading?” – still remains open to answers.

  12. MRI in head trauma

    International Nuclear Information System (INIS)

    Hong, Jin Kyo

    1986-01-01

    In the diagnosis of head injury, Magnetic Resonance Imaging (MRI), like CT, is an effective method of distinguishing between intracerebral and extracerebral lesions. In our experience of MRI, early hematomas are almost isointense by Saturation Recovery (SR) method, so these must be performed with Spin Echo (SE) method for better visualization of hematomas. Isodense subdural hematomas, which is a diagnostic dilemma on CT images, are clearly seen on MRI. Delayed hematomas or residual parenchymal lesions are better demonstrated on MRI than on CT. Direct cornal, sagittal images and multiplanar facility of MRI provides excellent visualization of the the location and shape of extracerebral collection of hematoma. For the screening of head traumas, SE method is a technique of choice because of its excellent sensitivity within limited time.

  13. "Head versus heart"

    Directory of Open Access Journals (Sweden)

    Paul Rozin

    2007-08-01

    Full Text Available Most American respondents give ``irrational,'' magical responses in a variety of situations that exemplify the sympathetic magical laws of similarity and contagion. In most of these cases, respondents are aware that their responses (usually rejections, as of fudge crafted to look like dog feces, or a food touched by a sterilized, dead cockroach are not ``scientifically'' justified, but they are willing to avow them. We interpret this, in some sense, as ``heart over head.'' We report in this study that American adults and undergraduates are substantially less likely to acknowledge magical effects when the judgments involve money (amount willing to pay to avoid an ``unpleasant'' magical contact than they are when using preference or rating measures. We conclude that in ``head-heart'' conflicts of this type, money tips the balance towards the former, or, in other words, that money makes the mind less magical.

  14. seasonal population dynamics of rodents of mount chilalo, arsi ...

    African Journals Online (AJOL)

    Preferred Customer

    ABSTRACT: A study on seasonal population dynamics of rodents was carried out on Mount. Chilalo from .... vegetation growth, availability of food and water, and ... vegetation (3,300–4,200 masl) (Alemayehu. Mengistu, 1975; APEDO and ABRDP, 2004). The mountain is one of the Afrotropical biodiversity hotspots areas.

  15. Vegetation types on Mount Akiki, Northern Luzon, Philippines

    NARCIS (Netherlands)

    Bout, I.E.

    2002-01-01

    Mount Akiki (16° 37’ N, 120° 53’ E, c. 2760 m alt.) is one of the highest mountain peaks in the Cordillera mountain range, Luzon Island, Philippines. It is situated in the municipality of Benguet, north-east of Baguio City (a world famous tourist city in the region) and is north-west of Mt Pulog,

  16. Kuidas koostada meeskonda - Mount Everesti ainetel / Marii Karell

    Index Scriptorium Estoniae

    Karell, Marii, 1980-

    2003-01-01

    Eesti meeskonna Mount Everesti tippu juhtinud Tõivo Sarmet selgitab toimunud ekspeditsiooni näitel, miks tema peab meeskonna komplekteerimisel oluliseimaks inimeste iseloomuomadusi. Ekstreemoludes hakkama saamiseks tuleb meeles pidada, et eesmärk on ühine ja kellegi ego ei tohi seda nurjata, rõhutab Sarmet. Kommenteerib Alar Sikk

  17. Nozzle Mounting Method Optimization Based on Robot Kinematic Analysis

    Science.gov (United States)

    Chen, Chaoyue; Liao, Hanlin; Montavon, Ghislain; Deng, Sihao

    2016-08-01

    Nowadays, the application of industrial robots in thermal spray is gaining more and more importance. A desired coating quality depends on factors such as a balanced robot performance, a uniform scanning trajectory and stable parameters (e.g. nozzle speed, scanning step, spray angle, standoff distance). These factors also affect the mass and heat transfer as well as the coating formation. Thus, the kinematic optimization of all these aspects plays a key role in order to obtain an optimal coating quality. In this study, the robot performance was optimized from the aspect of nozzle mounting on the robot. An optimized nozzle mounting for a type F4 nozzle was designed, based on the conventional mounting method from the point of view of robot kinematics validated on a virtual robot. Robot kinematic parameters were obtained from the simulation by offline programming software and analyzed by statistical methods. The energy consumptions of different nozzle mounting methods were also compared. The results showed that it was possible to reasonably assign the amount of robot motion to each axis during the process, so achieving a constant nozzle speed. Thus, it is possible optimize robot performance and to economize robot energy.

  18. Polynomial modal analysis of lamellar diffraction gratings in conical mounting.

    Science.gov (United States)

    Randriamihaja, Manjakavola Honore; Granet, Gérard; Edee, Kofi; Raniriharinosy, Karyl

    2016-09-01

    An efficient numerical modal method for modeling a lamellar grating in conical mounting is presented. Within each region of the grating, the electromagnetic field is expanded onto Legendre polynomials, which allows us to enforce in an exact manner the boundary conditions that determine the eigensolutions. Our code is successfully validated by comparison with results obtained with the analytical modal method.

  19. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    DEFF Research Database (Denmark)

    Groitl, Felix; Bartkowiak, Marek; Bergmann, Ryan M.

    2017-01-01

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each...

  20. Design of the GOES Telescope secondary mirror mounting

    Science.gov (United States)

    Hookman, Robert A.

    1989-01-01

    The GOES Telescope utilizes a flexure mounting system for the secondary mirror to minimize thermally induced distortions of the secondary mirror. The detailed design is presented along with a discussion of the microradian pointing requirements and how they were achieved. The methodology used to dynamically tune the flexure/secondary mirror assembly to minimize structural interactions will also be discussed.

  1. Adjustable bipod flexures for mounting mirrors in a space telescope.

    Science.gov (United States)

    Kihm, Hagyong; Yang, Ho-Soon; Moon, Il Kweon; Yeon, Jeong-Heum; Lee, Seung-Hoon; Lee, Yun-Woo

    2012-11-10

    A new mirror mounting technique applicable to the primary mirror in a space telescope is presented. This mounting technique replaces conventional bipod flexures with flexures having mechanical shims so that adjustments can be made to counter the effects of gravitational distortion of the mirror surface while being tested in the horizontal position. Astigmatic aberration due to the gravitational changes is effectively reduced by adjusting the shim thickness, and the relation between the astigmatism and the shim thickness is investigated. We tested the mirror interferometrically at the center of curvature using a null lens. Then we repeated the test after rotating the mirror about its optical axis by 180° in the horizontal setup, and searched for the minimum system error. With the proposed flexure mount, the gravitational stress at the adhesive coupling between the mirror and the mount is reduced by half that of a conventional bipod flexure for better mechanical safety under launch loads. Analytical results using finite element methods are compared with experimental results from the optical interferometer. Vibration tests verified the mechanical safety and optical stability, and qualified their use in space applications.

  2. Vertically mounted bifacial photovoltaic modules: A global analysis

    International Nuclear Information System (INIS)

    Guo, Siyu; Walsh, Timothy Michael; Peters, Marius

    2013-01-01

    Bifacial PV (photovoltaic) modules have recently come to increasing attention and various system designs have been investigated. In this paper, a global comparison is made between vertically mounted bifacial modules facing East–West and conventionally mounted mono-facial modules. An analytical method is used to calculate the radiation received by these two module configurations. It is found that the answer to the question which of these two module configurations performs better strongly depends on three factors: (i) the latitude, (ii) the local diffuse fraction and (iii) the albedo. In a subsequent part of the paper, the minimum albedo required to result in a better performance for vertically mounted bifacial modules is calculated for every place in the world. The calculation is based on measured data of the diffuse light fraction and the results are shown in the form of a global map. Finally, the albedo requirements are compared with the measured global albedo distribution. The calculation allows a distinct decision which module configuration is more suitable for a certain place in the world. The result is also shown as a map defining the corresponding areas. - Highlights: • Vertically mounted bifacial module and conventionally monofacial module are compared. • The key factors affecting the performance of the two configurations are investigated. • Which module configuration is more suitable for each place is shown in a world map. • The minimum albedo for bifacial modules to have a better performance is calculated

  3. Birds of Mount Kisingiri, Nyanza Province, including a preliminary ...

    African Journals Online (AJOL)

    Mount Kisingiri comprises a much overlooked highland massif in southern Nyanza. Province with a hitherto ..... This imbalance in relative species abundance within a defined ecological niche could .... Hills is unsuitable for foraging or breeding but there is extensive savanna grassland and suitable ..... Columba guinea nf.

  4. Biogeographic patterns of forest diversity at mount Kasigau, Kenya ...

    African Journals Online (AJOL)

    The study reports 140 species, 46 were measured in only one plot, and affinities for 75 species to the Somalia-Masai (43%), Afromontane (29%), and Zanzibar- Inhambane (Coastal, 28%) floristic regions. Cluster and Indicator Species Analyses identified eight community types. Mount Kasigau uniquely conserves much ...

  5. Improved resolution by mounting of tissue sections for laser microdissection.

    NARCIS (Netherlands)

    Dijk, M.C.R.F. van; Rombout, P.D.M.; Dijkman, H.B.P.M.; Ruiter, D.J.; Bernsen, M.R.

    2003-01-01

    BACKGROUND: Laser microbeam microdissection has greatly facilitated the procurement of specific cell populations from tissue sections. However, the fact that a coverslip is not used means that the morphology of the tissue sections is often poor. AIMS: To develop a mounting method that greatly

  6. Rollin' in Style!: Students Design Bike Mounted Skateboard Racks

    Science.gov (United States)

    Massey, Rick

    2008-01-01

    Recognizing the increasing popularity of skateboarding, the author has found a project that teaches design and manufacturing concepts--and, of equal importance, really gets his students motivated. He challenges them to design and build a skateboard rack that mounts easily on a bicycle. The project benefits students by teaching creativity, the…

  7. The mount Cameroon height determined from ground gravity data ...

    African Journals Online (AJOL)

    Abstract This paper deals with the accurate determination of mount Cameroon orthometric height, by combining ground gravity data, global navigation satellite system (GNSS) observations and global geopotential models. The elevation of the highest point (Fako) is computed above the WGS84 reference ellipsoid.

  8. Volcano ecology: flourishing on the flanks of Mount St. Helens

    Science.gov (United States)

    Rhonda Mazza; Charlie Crisafulli

    2016-01-01

    Mount St. Helens’ explosive eruption on May 18, 1980, was a pivotal moment in the field of disturbance ecology. The subsequent sustained, integrated research effort has shaped the development of volcano ecology, an emerging field of focused research. Excessive heat, burial, and impact force are some of the disturbance mechanisms following an eruption. They are also...

  9. Mount St. Helens 30 years later: a landscape reconfigured.

    Science.gov (United States)

    Rhonda Mazza

    2010-01-01

    On May 18, 1980, after two months of tremors, Mount St. Helens erupted spectacularly and profoundly changed a vast area surrounding the volcano. The north slope of the mountain catastrophically failed, forming the largest landslide witnessed in modern times. The largest lobe of this debris avalanche raced 14 miles down the Toutle River...

  10. Mount St. Helens: Still erupting lessons 31 years later

    Science.gov (United States)

    Rhonda Mazza; Charlie Crisafulli; Fred Swanson

    2011-01-01

    The massive volcanic eruption of Mount St. Helens 31 years ago provided the perfect backdrop for studying the earliest stages of forest development. Immediately after the eruption, some areas of the blast area were devoid of life. On other parts of the volcanic landscape, many species survived, although their numbers were greatly reduced. Reassembly began at many...

  11. Assessing climate change impacts on water balance in the Mount

    Indian Academy of Sciences (India)

    A statistical downscaling known for producing station-scale climate information from GCM output was preferred to evaluate the impacts of climate change within the Mount Makiling forest watershed, Philippines. The lumped hydrologic BROOK90 model was utilized for the water balance assessment of climate change ...

  12. Ethnobotanical survey of \\'wild\\' woody plant resources at Mount ...

    African Journals Online (AJOL)

    This paper focuses on the naming and use of plants by Taita who live at Mount Kasigau in Kenya's Eastern Arc Mountains. Plant vouchers and ethnobotanical data were compiled from transects and within 55 ecological plots, and during participant observations, home surveys, and semi-structured interviews with residents.

  13. Forest Carbon Stocks in Woody Plants of Mount Zequalla Monastery ...

    African Journals Online (AJOL)

    Carbon sequestration through forestry has the potential to play a significant role in ameliorating global environmental problems such as atmospheric accumulation of GHG's and climate change.The present study was undertaken to estimate forest carbon stock along altitudinal gradient in Mount Zequalla Monastery forest.

  14. Astrophotography on the go using short exposures with light mounts

    CERN Document Server

    Ashley, Joseph

    2015-01-01

    No longer are heavy, sturdy, expensive mounts and tripods required to photograph deep space. With today's advances in technology, all that is required is an entry-DSLR and an entry level GoTo telescope. Here is all of the information needed to start photographing the night sky without buying expensive tracking mounts. By using multiple short exposures and combining them with mostly ‘freeware’ computer programs, the effect of image rotation can be minimized to a point where it is undetectable in normal astrophotography, even for a deep-sky object such as a galaxy or nebula. All the processes, techniques, and equipment needed to use inexpensive, lightweight altazimuth and equatorial mounts and very short exposures photography to image deep space objects are explained, step-by-step, in full detail, supported by clear, easy to understand graphics and photographs.   Currently available lightweight mounts and tripods are identified and examined from an economic versus capability perspective to help users deter...

  15. 25 years of ecological change at Mount St. Helens.

    Science.gov (United States)

    V.H. Dale; C.M. Crisafulli; F.J. Swanson

    2005-01-01

    18 May 2005 marks the 25th anniversary of the massive eruption of Mount St. Helens. This eruption involved diverse geological processes (1) that disturbed forests, meadows, lakes, an drivers (2) (see the figure). A huge landslide and searing flows of hot gases and pumic framents (pyroclastic flows) inundated 60 km2 of land, obliterating...

  16. [The exploding head syndrome].

    Science.gov (United States)

    Bongers, K M; ter Bruggen, J P; Franke, C L

    1991-04-06

    The case is reported of a 47-year old female suffering from the exploding head syndrome. This syndrome consists of a sudden awakening due to a loud noise shortly after falling asleep, sometimes accompanied by a flash of light. The patient is anxious and experiences palpitations and excessive sweating. Most patients are more than fifty years of age. Further investigations do not reveal any abnormality. The pathogenesis is unknown, and no therapy other than reassurance is necessary.

  17. Where are we heading

    International Nuclear Information System (INIS)

    Noto, L.A.

    1996-01-01

    The present paper deals with different aspects connected to the global petroleum industry by discussing the way of heading. The aspects cover themes like new frontiers, new relationships, sanctions, global climate change, new alliances and new technology. New frontiers and relationships concern domestic policy affecting the industry, and sanctions are discussed in connection with trade. The author discusses the industry's participation in the global environmental policy and new alliances to provide greater opportunity for developing new technology

  18. "Head versus heart"

    OpenAIRE

    Paul Rozin; Heidi Grant; Stephanie Weinberg; Scott Parker

    2007-01-01

    Most American respondents give ``irrational,'' magical responses in a variety of situations that exemplify the sympathetic magical laws of similarity and contagion. In most of these cases, respondents are aware that their responses (usually rejections, as of fudge crafted to look like dog feces, or a food touched by a sterilized, dead cockroach) are not ``scientifically'' justified, but they are willing to avow them. We interpret this, in some sense, as ``heart over head.'' We report in this ...

  19. Head segmentation in vertebrates

    OpenAIRE

    Kuratani, Shigeru; Schilling, Thomas

    2008-01-01

    Classic theories of vertebrate head segmentation clearly exemplify the idealistic nature of comparative embryology prior to the 20th century. Comparative embryology aimed at recognizing the basic, primary structure that is shared by all vertebrates, either as an archetype or an ancestral developmental pattern. Modern evolutionary developmental (Evo-Devo) studies are also based on comparison, and therefore have a tendency to reduce complex embryonic anatomy into overly simplified patterns. Her...

  20. Geologic Map of Mount Mazama and Crater Lake Caldera, Oregon

    Science.gov (United States)

    Bacon, Charles R.

    2008-01-01

    Crater Lake partly fills one of the most spectacular calderas of the world, an 8-by-10-km basin more than 1 km deep formed by collapse of the volcano known as Mount Mazama (fig. 1) during a rapid series of explosive eruptions about 7,700 years ago. Having a maximum depth of 594 m, Crater Lake is the deepest lake in the United States. Crater Lake National Park, dedicated in 1902, encompasses 645 km2 of pristine forested and alpine terrain, including the lake itself, virtually all of Mount Mazama, and most of the area of the geologic map. The geology of the area was first described in detail by Diller and Patton (1902) and later by Williams (1942), whose vivid account led to international recognition of Crater Lake as the classic collapse caldera. Because of excellent preservation and access, Mount Mazama, Crater Lake caldera, and the deposits formed by the climactic eruption constitute a natural laboratory for study of volcanic and magmatic processes. For example, the climactic ejecta are renowned among volcanologists as evidence for systematic compositional zonation within a subterranean magma chamber. Mount Mazama's climactic eruption also is important as the source of the widespread Mazama ash, a useful Holocene stratigraphic marker throughout the Pacific Northwest, adjacent Canada, and offshore. A detailed bathymetric survey of the floor of Crater Lake in 2000 (Bacon and others, 2002) provides a unique record of postcaldera eruptions, the interplay between volcanism and filling of the lake, and sediment transport within this closed basin. Knowledge of the geology and eruptive history of the Mount Mazama edifice, greatly enhanced by the caldera wall exposures, gives exceptional insight into how large volcanoes of magmatic arcs grow and evolve. Lastly, the many smaller volcanoes of the High Cascades beyond the limits of Mount Mazama are a source of information on the flux of mantle-derived magma through the region. General principles of magmatic and eruptive

  1. Rotation and direction judgment from visual images head-slaved in two and three degrees-of-freedom.

    Science.gov (United States)

    Adelstein, B D; Ellis, S R

    2000-03-01

    The contribution to spatial awareness of adding a roll degree-of-freedom (DOF) to telepresence camera platform yaw and pitch was examined in an experiment where subjects judged direction and rotation of stationary target markers in a remote scene. Subjects viewed the scene via head-slaved camera images in a head-mounted display. Elimination of the roll DOF affected rotation judgment, but only at extreme yaw and pitch combinations, and did not affect azimuth and elevation judgement. Systematic azimuth overshoot occurred regardless of roll condition. Observed rotation misjudgments are explained by kinematic models for eye-head direction of gaze.

  2. Effect of external viscous load on head movement

    Science.gov (United States)

    Nam, M.-H.; Lakshminarayanan, V.; Stark, L. W.

    1984-01-01

    Quantitative measurements of horizontal head rotation were obtained from normal human subjects intending to make 'time optimal' trajectories between targets. By mounting large, lightweight vanes on the head, viscous damping B, up to 15 times normal could be added to the usual mechanical load of the head. With the added viscosity, the head trajectory was slowed and of larger duration (as expected) since fixed and maximal (for that amplitude) muscle forces had to accelerate the added viscous load. This decreased acceleration and velocity and longer duration movement still ensued in spite of adaptive compensation; this provided evidence that quasi-'time optimal' movements do indeed employ maximal muscle forces. The adaptation to this added load was rapid. Then the 'adapted state' subjects produced changed trajectories. The adaptation depended in part on the differing detailed instructions given to the subjects. This differential adaptation provided evidence for the existence of preprogrammed controller signals, sensitive to intended criterion, and neurologically ballistic or open loop rather than modified by feedback from proprioceptors or vision.

  3. Head Impact Exposure in Junior and Adult Australian Football Players

    Directory of Open Access Journals (Sweden)

    Mark Hecimovich

    2018-01-01

    Full Text Available This study measured and compared the frequency, magnitude, and distribution of head impacts sustained by junior and adult Australian football players, respectively, and between player positions over a season of games. Twelve junior and twelve adult players were tracked using a skin-mounted impact sensor. Head impact exposure, including frequency, magnitude, and location of impacts, was quantified using previously established methods. Over the collection period, there were no significant differences in the impact frequency between junior and adult players. However, there was a significant increase in the frequency of head impacts for midfielders in both grades once we accounted for player position. A comparable amount of head impacts in both junior and adult players has implications for Australian football regarding player safety and medical coverage as younger players sustained similar impact levels as adult players. The other implication of a higher impact profile within midfielders is that, by targeting education and prevention strategies, a decrease in the incidence of sports-related concussion may result.

  4. Correction of head movements in positron emission tomography using point source tracking system: a simulation study.

    Science.gov (United States)

    Nazarparvar, Babak; Shamsaei, Mojtaba; Rajabi, Hossein

    2012-01-01

    The motion of the head during brain positron emission tomography (PET) acquisitions has been identified as a source of artifact in the reconstructed image. In this study, a method is described to develop an image-based motion correction technique for correcting the post-acquisition data without using external optical motion-tracking system such as POLARIS. In this technique, GATE has been used to simulate PET brain scan using point sources mounted around the head to accurately monitor the position of the head during the time frames. The measurement of head motion in each frame showed a transformation in the image frame matrix, resulting in a fully corrected data set. Using different kinds of phantoms and motions, the accuracy of the correction method is tested and its applicability to experimental studies is demonstrated as well.

  5. Flat mount preparation for observation and analysis of zebrafish embryo specimens stained by whole mount in situ hybridization.

    Science.gov (United States)

    Cheng, Christina N; Li, Yue; Marra, Amanda N; Verdun, Valerie; Wingert, Rebecca A

    2014-07-17

    The zebrafish embryo is now commonly used for basic and biomedical research to investigate the genetic control of developmental processes and to model congenital abnormalities. During the first day of life, the zebrafish embryo progresses through many developmental stages including fertilization, cleavage, gastrulation, segmentation, and the organogenesis of structures such as the kidney, heart, and central nervous system. The anatomy of a young zebrafish embryo presents several challenges for the visualization and analysis of the tissues involved in many of these events because the embryo develops in association with a round yolk mass. Thus, for accurate analysis and imaging of experimental phenotypes in fixed embryonic specimens between the tailbud and 20 somite stage (10 and 19 hours post fertilization (hpf), respectively), such as those stained using whole mount in situ hybridization (WISH), it is often desirable to remove the embryo from the yolk ball and to position it flat on a glass slide. However, performing a flat mount procedure can be tedious. Therefore, successful and efficient flat mount preparation is greatly facilitated through the visual demonstration of the dissection technique, and also helped by using reagents that assist in optimal tissue handling. Here, we provide our WISH protocol for one or two-color detection of gene expression in the zebrafish embryo, and demonstrate how the flat mounting procedure can be performed on this example of a stained fixed specimen. This flat mounting protocol is broadly applicable to the study of many embryonic structures that emerge during early zebrafish development, and can be implemented in conjunction with other staining methods performed on fixed embryo samples.

  6. Controlled Metal Detector Mounted on Mine Detection Robot

    Directory of Open Access Journals (Sweden)

    Seiji Masunaga

    2007-06-01

    Full Text Available Landmine detection capability of metal detectors is very sensitive to the gap between buried landmines and the sensor heads. Therefore, human deminers manually scan ground surface with the metal detectors in such a manner that the sensor heads follow the ground surface. In case of robots assisted landmine detection, this function can be performed accurately and safely by controlling the gap and attitude of the sensor heads. In this investigation, the effectiveness of the gap and attitude control of the sensor head by some mechanical manipulator on the landmine detection performance has been addressed quantitatively. To this end, the paper describes the development of a Controlled Metal Detector (CMD for controlling the gap and attitude of the sensor head. The CMD generates trajectories of the sensor head from the depth information of the ground surface acquired with 3-D stereovision camera in order to avoid any obstacles and possible impact with the ground, and then tracks the trajectories with a trajectory-tracking controller. The effectiveness and the impact related to the gap and attitude control on the landmine detection performance of the CMD have been demonstrated by experimental studies.

  7. Kinematics of the AM-50 heading machine cutting head

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, W; Bak, K; Klich, R [Politechnika Slaska, Gliwice (Poland). Instytut Mechanizacji Gornictwa

    1987-01-01

    Analyzes motion of the cutter head of the AM-50 heading machine. Two types of head motion are comparatively evaluated: planar motion and spatial motion. The spatial motion consists of the head rotational motion and horizontal or vertical feed motion, while planar motion consists of rotational motion and vertical feed motion. Equations that describe head motion under conditions of cutter vertical or horizontal feed motion are derived. The angle between the cutting speed direction and working speed direction is defined. On the basis of these formulae variations of cutting speed depending on the cutting tool position on a cutter head are calculated. Calculations made for 2 extreme cutting tools show that the cutting speed ranges from 1,205 m/s to 3,512 m/s. 4 refs.

  8. Head First Web Design

    CERN Document Server

    Watrall, Ethan

    2008-01-01

    Want to know how to make your pages look beautiful, communicate your message effectively, guide visitors through your website with ease, and get everything approved by the accessibility and usability police at the same time? Head First Web Design is your ticket to mastering all of these complex topics, and understanding what's really going on in the world of web design. Whether you're building a personal blog or a corporate website, there's a lot more to web design than div's and CSS selectors, but what do you really need to know? With this book, you'll learn the secrets of designing effecti

  9. Head first C#

    CERN Document Server

    Stellman, Andrew

    2008-01-01

    Head First C# is a complete learning experience for object-oriented programming, C#, and the Visual Studio IDE. Built for your brain, this book covers C# 3.0 and Visual Studio 2008, and teaches everything from language fundamentals to advanced topics including garbage collection, extension methods, and double-buffered animation. You'll also master C#'s hottest and newest syntax, LINQ, for querying SQL databases, .NET collections, and XML documents. By the time you're through, you'll be a proficient C# programmer, designing and coding large-scale applications. Every few chapters you will come

  10. Head first C#

    CERN Document Server

    Stellman, Andrew

    2010-01-01

    You want to learn C# programming, but you're not sure you want to suffer through another tedious technical book. You're in luck: Head First C# introduces this language in a fun, visual way. You'll quickly learn everything from creating your first program to learning sophisticated coding skills with C# 4.0, Visual Studio 2010 and .NET 4, while avoiding common errors that frustrate many students. The second edition offers several hands-on labs along the way to help you build and test programs using skills you've learned up to that point. In the final lab, you'll put everything together. From o

  11. Head First Python

    CERN Document Server

    Barry, Paul

    2010-01-01

    Ever wished you could learn Python from a book? Head First Python is a complete learning experience for Python that helps you learn the language through a unique method that goes beyond syntax and how-to manuals, helping you understand how to be a great Python programmer. You'll quickly learn the language's fundamentals, then move onto persistence, exception handling, web development, SQLite, data wrangling, and Google App Engine. You'll also learn how to write mobile apps for Android, all thanks to the power that Python gives you. We think your time is too valuable to waste struggling with

  12. Head First Mobile Web

    CERN Document Server

    Gardner, Lyza; Grigsby, Jason

    2011-01-01

    Despite the huge number of mobile devices and apps in use today, your business still needs a website. You just need it to be mobile. Head First Mobile Web walks you through the process of making a conventional website work on a variety smartphones and tablets. Put your JavaScript, CSS media query, and HTML5 skills to work-then optimize your site to perform its best in the demanding mobile market. Along the way, you'll discover how to adapt your business strategy to target specific devices. Navigate the increasingly complex mobile landscapeTake both technical and strategic approaches to mobile

  13. Controversies surrounding Human Papilloma Virus infection, head & neck vs oral cancer, implications for prophylaxis and treatment

    OpenAIRE

    Campisi, G.; Giovannelli, L.

    2009-01-01

    Head & Neck Cancer (HNC) represents the sixth most common malignancy worldwide and it is historically linked to well-known behavioural risk factors, i.e., tobacco smoking and/or the alcohol consumption. Recently, substantial evidence has been mounting that Human Papillomavirus (HPV) infection is playing an increasing important role in oral cancer. Because of the attention and clamor surrounding oral HPV infection and related cancers, as well as the use of HPV prophylactic vaccines, in this in...

  14. Reactor vessel head permanent shield

    International Nuclear Information System (INIS)

    Hankinson, M.F.; Leduc, R.J.; Richard, J.W.; Malandra, L.J.

    1989-01-01

    A nuclear reactor is described comprising: a nuclear reactor pressure vessel closure head; control rod drive mechanisms (CRDMs) disposed within the closure head so as to project vertically above the closure head; cooling air baffle means surrounding the control rod drive mechanisms for defining cooling air paths relative to the control rod drive mechanisms; means defined within the periphery of the closure head for accommodating fastening means for securing the closure head to its associated pressure vessel; lifting lugs fixedly secured to the closure head for facilitating lifting and lowering movements of the closure head relative to the pressure vessel; lift rods respectively operatively associated with the plurality of lifting lugs for transmitting load forces, developed during the lifting and lowering movements of the closure head, to the lifting lugs; upstanding radiation shield means interposed between the cooling air baffle means and the periphery of the enclosure head of shielding maintenance personnel operatively working upon the closure head fastening means from the effects of radiation which may emanate from the control rod drive mechanisms and the cooling air baffle means; and connecting systems respectively associated with each one of the lifting lugs and each one of the lifting rods for connecting each one of the lifting rods to a respective one of each one of the lifting lugs, and for simultaneously connecting a lower end portion of the upstanding radiation shield means to each one of the respective lifting lugs

  15. Mounting of Biomaterials for Use in Ophthalmic Cell Therapies.

    Science.gov (United States)

    Harkin, Damien G; Dunphy, Siobhan E; Shadforth, Audra M A; Dawson, Rebecca A; Walshe, Jennifer; Zakaria, Nadia

    2017-11-01

    When used as scaffolds for cell therapies, biomaterials often present basic handling and logistical problems for scientists and surgeons alike. The quest for an appropriate mounting device for biomaterials is therefore a significant and common problem. In this review, we provide a detailed overview of the factors to consider when choosing an appropriate mounting device including those experienced during cell culture, quality assurance, and surgery. By way of example, we draw upon our combined experience in developing epithelial cell therapies for the treatment of eye diseases. We discuss commercially available options for achieving required goals and provide a detailed analysis of 4 experimental designs developed within our respective laboratories in Australia, the United Kingdom, and Belgium.

  16. Apparatus for mounting photovoltaic power generating systems on buildings

    Science.gov (United States)

    Russell, Miles C [Lincoln, MA

    2009-08-18

    Rectangular photovoltaic (PV) modules are mounted on a building roof by mounting stands that are distributed in rows and columns. Each stand comprises a base plate and first and second different height brackets attached to opposite ends of the base plate. Each first and second bracket comprises two module-support members. One end of each module is pivotally attached to and supported by a first module-support member of a first bracket and a second module-support member of another first bracket. At its other end each module rests on but is connected by flexible tethers to module-support members of two different second brackets. The tethers are sized to allow the modules to pivot up away from the module-support members on which they rest to a substantially horizontal position in response to wind uplift forces.

  17. Whole mount nuclear fluorescent imaging: convenient documentation of embryo morphology.

    Science.gov (United States)

    Sandell, Lisa L; Kurosaka, Hiroshi; Trainor, Paul A

    2012-11-01

    Here, we describe a relatively inexpensive and easy method to produce high quality images that reveal fine topological details of vertebrate embryonic structures. The method relies on nuclear staining of whole mount embryos in combination with confocal microscopy or conventional wide field fluorescent microscopy. In cases where confocal microscopy is used in combination with whole mount nuclear staining, the resulting embryo images can rival the clarity and resolution of images produced by scanning electron microscopy (SEM). The fluorescent nuclear staining may be performed with a variety of cell permeable nuclear dyes, enabling the technique to be performed with multiple standard microscope/illumination or confocal/laser systems. The method may be used to document morphology of embryos of a variety of organisms, as well as individual organs and tissues. Nuclear stain imaging imposes minimal impact on embryonic specimens, enabling imaged specimens to be utilized for additional assays. Copyright © 2012 Wiley Periodicals, Inc.

  18. Siting study for small platform-mounted industrial energy reactors

    International Nuclear Information System (INIS)

    1975-07-01

    Utilizing an existing 313 MW(t) ship propulsion reactor design, a concept has been formulated for a floating platform-mounted nuclear plant and an evaluation has been made to determine reductions in construction time and cost achievable by repetitive platform construction in a shipyard. Concepts and estimates are presented for siting platform-mounted nuclear plants at the location of industrial facilities where the nuclear plants would furnish industrial process heat and/or electrical power. The representative industrial site designated for this study is considered typical of sites that might be used along the extensive network of navigable canals adjacent to the ocean and is similar to potential sites along the inland waterways of the United States

  19. Preparation of source mounts for 4π counting

    International Nuclear Information System (INIS)

    Johnson, E.P.

    1991-01-01

    The 4πβ/γ counter in the ANSTO radioisotope standards laboratory at Lucas Heights constitutes part of the Australian national standard for radioactivity. Sources to be measured in the counter must be mounted on a substrate which is strong enough to withstand careful handling and transport. The substrate must also be electrically conducting to minimise counting errors caused by charging of the source, and it must have very low superficial density so that little or none of the radiation is absorbed. The entire process of fabrication of VYNS films, coating them with gold/palladium and transferring them to source mount rings, as carried out in the radioisotope standards laboratory, is documented. 3 refs., 2 tabs., 6 figs

  20. Righteousness and identity formation in the Sermon on the Mount

    Directory of Open Access Journals (Sweden)

    Francois P. Viljoen

    2013-03-01

    Full Text Available Righteousness is an important term in the first gospel and has a significant concentration in the Sermon on the Mount. The argument in this article is that the first gospel has a community building function. Matthew intentionally uses the word ‘righteousness’ in the Sermon on the Mount as an instrument to define the identity of his community. Though righteousness can be used in a soteriological sense, it is argued that Matthew mainly uses it in an ethical sense. By righteousness Matthew refers to the proper behavioural norms and attitudes for his community. Commitment to Jesus forms the central focus of the community’s identity. Their discipleship is demonstrated by doing the will of God as defined and interpreted by Jesus. Doing the will of God in such a manner is what Matthew regards as the distinguishing mark of this community. Thus they would surpass the righteousness of the scribes and Pharisees.

  1. Longitudinally mounted light emitting plasma in a dielectric resonator

    Energy Technology Data Exchange (ETDEWEB)

    Gilliard, Richard; DeVincentis, Marc; Hafidi, Abdeslam; O' Hare, Daniel; Hollingsworth, Gregg [LUXIM Corporation, 1171 Borregas Avenue, Sunnyvale, CA 94089 (United States)

    2011-06-08

    Methods for coupling power from a dielectric resonator to a light-emitting plasma have been previously described (Gilliard et al IEEE Trans. Plasma Sci. at press). Inevitably, regardless of the efficiency of power transfer, much of the emitted light is absorbed in the resonator itself which physically surrounds much if not all of the radiating material. An investigation into a method is presented here for efficiently coupling power to a longitudinally mounted plasma vessel which is mounted on the surface of the dielectric material of the resonator, thereby eliminating significant absorption of light within the resonator structure. The topology of the resonator and its physical properties as well as those of the metal halide plasma are presented. Results of basic models of the field configuration and plasma are shown as well as a configuration suitable as a practical light source.

  2. Tsunamis generated by eruptions from mount st. Augustine volcano, alaska.

    Science.gov (United States)

    Kienle, J; Kowalik, Z; Murty, T S

    1987-06-12

    During an eruption of the Alaskan volcano Mount St. Augustine in the spring of 1986, there was concern about the possibility that a tsunami might be generated by the collapse of a portion of the volcano into the shallow water of Cook Inlet. A similar edifice collapse of the volcano and ensuing sea wave occurred during an eruption in 1883. Other sea waves resulting in great loss of life and property have been generated by the eruption of coastal volcanos around the world. Although Mount St. Augustine remained intact during this eruptive cycle, a possible recurrence of the 1883 events spurred a numerical simulation of the 1883 sea wave. This simulation, which yielded a forecast of potential wave heights and travel times, was based on a method that could be applied generally to other coastal volcanos.

  3. Ground mounted photovoltaic installations. Guide for an impact study

    International Nuclear Information System (INIS)

    2011-01-01

    Legally, an impact study must be performed for ground mounted photovoltaic installations with a power greater than 250 kW. This guide is aimed at helping the actors of the photovoltaic sector to perform impact studies. After the description of the characteristics of a photovoltaic installation (principles, technical characteristics of a ground mounted installation, impact of photovoltaic systems on climate) and a presentation of the legal framework (European commitments, Grenelle de l'Environnement, applicable procedures), this report present the objectives and approach of an impact study, describes how the environment is taken into account from the early stages of a project, how the impact study is to be prepared. The last part describes the different components of the impact study: legal content, project description, analysis of the site initial status and environment, analysis of the project effects, rationale for the choice of the project

  4. The auriferous placer at Mount Robert, Pietersburg Greenstone belt

    International Nuclear Information System (INIS)

    Saager, R.; Muff, R.

    1986-01-01

    The Mount Robert gold placer near Potgietersrus occurs in coarse, matrix-supported conglomerates of the Uitkyk Formation within the Pietersburg greenstone belt. Sedimentological and mineralogical investigations indicate that the conglomerates and the ore minerals were derived from a greenstone provenance, and that they were deposited in a braided river environment within a rapidly subsiding trough. Lack of sedimentological concentration of the heavy minerals is considered to be the main reason for the low and erratic gold grades encountered (usually below 1 g/t) and, thus, the failure of all past mining ventures. The mineralogical composition of the Mount Robert ore closely resembles that of the Witwatersrand deposits. However, uraninite is absent, probably as a result of its complete removal by weathering processes. Remaining small uranium concentrations can still be detected within the conglomerates where they occur associated with grains of carbonaceous matter, leucoxene aggregates, and secondary iron-hydroxides. U3O8 values found in the conglomerates are given

  5. Fluorescent visualization of macromolecules in Drosophila whole mounts.

    Science.gov (United States)

    Ramos, Ricardo Guelerman Pinheiro; Machado, Luciana Claudia Herculano; Moda, Livia Maria Rosatto

    2010-01-01

    The ability to determine the expression dynamics of individual genes "in situ" by visualizing the precise spatial and temporal distribution of their products in whole mounts by histochemical and immunocytochemical reactions has revolutionized our understanding of cellular processes. Drosophila developmental genetics was one of the fields that benefited most from these technologies, and a variety of fluorescent methods were specifically designed for investigating the localization of developmentally important proteins and cell markers during embryonic and post embryonic stages of this model organism. In this chapter we present detailed protocols for fluorescence immunocytochemistry of whole mount embryos, imaginal discs, pupal retinas, and salivary glands of Drosophila melanogaster, as well as methods for fluorescent visualization of specific subcellular structures in these tissues.

  6. Binocular Rivalry in Helmet-Mounted Display Applications

    Science.gov (United States)

    1975-06-01

    research apparatus. 31 ., simple magnifying ophthalmic lenses were used, mounted in eyeglass frames. These were 2. 5 diopter lenses for both eyes to...wear eyeglasses with 2. 5 diopter lenses. The focal length of these lenses was 15. 5 inches and the eye waa accommodated at infinity when objects were...HMD luminance is positively related to I-I•D visibility, while ambient scene luminance bears an inverse relation- ship to HMD visibility. Scene

  7. Method to mount defect fuel elements i transport casks

    International Nuclear Information System (INIS)

    Borgers, H.; Deleryd, R.

    1996-01-01

    Leaching or otherwise failed fuel elements are mounted in special containers that fit into specially designed chambers in a transportation cask for transport to reprocessing or long-time storage. The fuel elements are entered into the container under water in a pool. The interior of the container is dried before transfer to the cask. Before closing the cask, its interior, and the exterior of the container are dried. 2 figs

  8. Apollo telescope mount thermal systems unit thermal vacuum test

    Science.gov (United States)

    Trucks, H. F.; Hueter, U.; Wise, J. H.; Bachtel, F. D.

    1971-01-01

    The Apollo Telescope Mount's thermal systems unit was utilized to conduct a full-scale thermal vacuum test to verify the thermal design and the analytical techniques used to develop the thermal mathematical models. Thermal vacuum test philosophy, test objectives configuration, test monitoring, environment simulation, vehicle test performance, and data correlation are discussed. Emphasis is placed on planning and execution of the thermal vacuum test with particular attention on problems encountered in conducting a test of this maguitude.

  9. Quality assurance during construction and mounting of the Balakovo NPP

    International Nuclear Information System (INIS)

    Savkin, A.I.; Vorob'ev, N.G.; Kugrysheva, M.A.

    1984-01-01

    Measures directed at opportune comissioning of the first unit of Balakovo NPP with the caracity 1000 MW(el.) are briefly described. A high quality of construction and mounting works is achieved due to a high level of engeneering preparation in the industry, organization of daily control over the works implementation and quality of products and materials supplied, by the improvement of automation and introduction of progressive forms of organization and remuneration

  10. Eddy current testing system for bottom mounted instrumentation welds

    OpenAIRE

    Kobayashi Noriyasu; Ueno Souichi; Suganuma Naotaka; Oodake Tatsuya; Maehara Takeshi; Kasuya Takashi; Ichikawa Hiroya

    2015-01-01

    The capability of eddy current testing (ECT) for the bottom mounted instrumentation (BMI) weld area of reactor vessel in a pressurized water reactor was demonstrated by the developed ECT system and procedure. It is difficult to position and move the probe on the BMI weld area because the area has complexly curved surfaces. The space coordinates and the normal vectors at the scanning points were calculated as the scanning trajectory of probe based on the measured results of surface shape on th...

  11. Isogloss: language and legacy on Mount St. Helens

    Science.gov (United States)

    E. Dodd

    2012-01-01

    Nothing standing aboveground today was here thirty years ago. The ground itself wasn't here. Oh, there was ground, but much of it lay below the surface where my boot soles slip a little in the loose pebbles of pumice. Rolling on loose rock and big ideas, for a moment I lose my sense of balance, glancing first at the sky above, then at the nearby peak of Mount St...

  12. Conceptual Design of Bottom-mounted Control Rod Drive Mechanism

    International Nuclear Information System (INIS)

    Lee, Jin Haeng; Kim, Sanghaun; Yoo, Yeonsik; Cho, Yeonggarp; Kim, Dongmin; Kim, Jong In

    2013-01-01

    The arrangement of the BMCRDMs and irradiation holes in the core is therefore easier than that of the top-mounted CRDM. Hence, many foreign research reactors, such as JRR-3M, JMTR, OPAL, and CARR, have adopted the BMCRDM concept. The purpose of this paper is to introduce the basic design concept on the BMCRDM. The major differences of the CRDMs between HANARO and KJRR are compared, and the design features and individual system of the BMCRDM for the KJRR are described. The Control Rod Drive Mechanism (CRDM) is a device to regulate the reactor power by changing the position of a Control Absorber Rod (CAR) and to shut down the reactor by fully inserting the CAR into the core within a specified time. The Bottom-Mounted CRDM (BMCRDM) for the KiJang Research Reactor (KJRR) is a quite different design concept compared to the top-mounted CRDM such as HANARO and JRTR. The main drive mechanism of the BMCRDM is located in a Reactivity Control Mechanism (RCM) room under the reactor pool bottom, which makes the interference with equipment in the reactor pool reduced

  13. A concept of active mount for space applications

    Science.gov (United States)

    Souleille, A.; Lampert, T.; Lafarga, V.; Hellegouarch, S.; Rondineau, A.; Rodrigues, G.; Collette, C.

    2018-06-01

    Sensitive payloads mounted on top of launchers are subjected to many sources of disturbances during the flight. The most severe dynamic loads arise from the ignition of the motors, gusts, pressure fluctuations in the booster and from the separation of the boosters. The transmission of these dynamic forces can be reduced by mounting payloads on passive isolators, which comes at the expense of harmful amplifications of the motion at low frequency due to suspension resonances. To bypass this shortcoming, this paper presents a novel concept of active mount for aerospace payloads, which is easy to install, and meets two objectives. The first one is a high damping authority on both suspension resonances and flexible resonances without compromising the isolation and large stability margins of the closed loop system due to the collocation of the actuator and the sensor. The second one is a broadband reduction of the dynamic force transmitted to the payload, which was achieved in terms of 16 dB. The concept is presented in the first part of the paper and studied numerically and experimentally on a single degree of freedom isolator. A commercial isolator has been chosen for the purpose of the demonstration. The second part of the paper is dedicated to experimental validations on multi-degree of freedom scaled test benches. It is shown that the force feedback allows damping of both suspension and flexible modes (first and second modes, respectively), and significantly reducing the force transmitted in some broad frequency ranges.

  14. On-field mounting position estimation of a lidar sensor

    Science.gov (United States)

    Khan, Owes; Bergelt, René; Hardt, Wolfram

    2017-10-01

    In order to retrieve a highly accurate view of their environment, autonomous cars are often equipped with LiDAR sensors. These sensors deliver a three dimensional point cloud in their own co-ordinate frame, where the origin is the sensor itself. However, the common co-ordinate system required by HAD (Highly Autonomous Driving) software systems has its origin at the center of the vehicle's rear axle. Thus, a transformation of the acquired point clouds to car co-ordinates is necessary, and thereby the determination of the exact mounting position of the LiDAR system in car coordinates is required. Unfortunately, directly measuring this position is a time-consuming and error-prone task. Therefore, different approaches have been suggested for its estimation which mostly require an exhaustive test-setup and are again time-consuming to prepare. When preparing a high number of LiDAR mounted test vehicles for data acquisition, most approaches fall short due to time or money constraints. In this paper we propose an approach for mounting position estimation which features an easy execution and setup, thus making it feasible for on-field calibration.

  15. Local Sabahans’ Satisfaction with Level of Access to Mount Kinabalu

    Directory of Open Access Journals (Sweden)

    Bidder Christy

    2014-01-01

    Full Text Available This study analyzes the local Sabahans’ satisfaction with the level of access to Mount Kinabalu in Sabah, Malaysian Borneo. Specifically, it examines the number of complaints by local Sabahans regarding access and their perception of changes in accessibility to the mountain. Interviews with Sabah Parks and Sutera Sanctuary Lodges were conducted and questionnaires were distributed to local residents to collect data. The results show that there were intense complaints regarding the climbing cost and extensive waiting time to secure a confirmed booking at the outset of price increases. However, the researchers could not locate any recently published complaints. Respondents who have previously climbed Mount Kinabalu perceive the mountain to be less accessible for local Sabahans now due to a less affordable cost and a longer waiting time. Those who have not climbed Mount Kinabalu also think the climbing cost has become less affordable for local Sabahans, but they do not perceive that to be causing the mountain less accessible for local Sabahans.

  16. A concept of active mount for space applications

    Science.gov (United States)

    Souleille, A.; Lampert, T.; Lafarga, V.; Hellegouarch, S.; Rondineau, A.; Rodrigues, G.; Collette, C.

    2017-10-01

    Sensitive payloads mounted on top of launchers are subjected to many sources of disturbances during the flight. The most severe dynamic loads arise from the ignition of the motors, gusts, pressure fluctuations in the booster and from the separation of the boosters. The transmission of these dynamic forces can be reduced by mounting payloads on passive isolators, which comes at the expense of harmful amplifications of the motion at low frequency due to suspension resonances. To bypass this shortcoming, this paper presents a novel concept of active mount for aerospace payloads, which is easy to install, and meets two objectives. The first one is a high damping authority on both suspension resonances and flexible resonances without compromising the isolation and large stability margins of the closed loop system due to the collocation of the actuator and the sensor. The second one is a broadband reduction of the dynamic force transmitted to the payload, which was achieved in terms of 16 dB. The concept is presented in the first part of the paper and studied numerically and experimentally on a single degree of freedom isolator. A commercial isolator has been chosen for the purpose of the demonstration. The second part of the paper is dedicated to experimental validations on multi-degree of freedom scaled test benches. It is shown that the force feedback allows damping of both suspension and flexible modes (first and second modes, respectively), and significantly reducing the force transmitted in some broad frequency ranges.

  17. Conceptual Design of Bottom-mounted Control Rod Drive Mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Haeng; Kim, Sanghaun; Yoo, Yeonsik; Cho, Yeonggarp; Kim, Dongmin; Kim, Jong In [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The arrangement of the BMCRDMs and irradiation holes in the core is therefore easier than that of the top-mounted CRDM. Hence, many foreign research reactors, such as JRR-3M, JMTR, OPAL, and CARR, have adopted the BMCRDM concept. The purpose of this paper is to introduce the basic design concept on the BMCRDM. The major differences of the CRDMs between HANARO and KJRR are compared, and the design features and individual system of the BMCRDM for the KJRR are described. The Control Rod Drive Mechanism (CRDM) is a device to regulate the reactor power by changing the position of a Control Absorber Rod (CAR) and to shut down the reactor by fully inserting the CAR into the core within a specified time. The Bottom-Mounted CRDM (BMCRDM) for the KiJang Research Reactor (KJRR) is a quite different design concept compared to the top-mounted CRDM such as HANARO and JRTR. The main drive mechanism of the BMCRDM is located in a Reactivity Control Mechanism (RCM) room under the reactor pool bottom, which makes the interference with equipment in the reactor pool reduced.

  18. Vibration aging of diesel-engine mounted electrical equipment

    International Nuclear Information System (INIS)

    Lee, B.J.; Morton, W.C.

    1994-01-01

    The Emergency Diesel Generator (EDG) in a Nuclear Power Plant is considered to be a component which is essential to safe plant operation. Failures of auxiliary equipment directly mounted on the EDG creates costly repairs, and compromises the engine's availability and reliability. Although IEEE-323 requires addressing of safety-related components due to mechanically induced vibration, very few guidelines exist in the nuclear industry to show how this may be accounted for. Most engine vendors rely on the empirical experience data as the basis of their evaluation for vibration. Upgrade of engine controls, addition of monitoring devices and other engine modifications require design and installation of new equipment to be mounted directly on the engine. This necessitates the evaluation for engine-induced vibration which is considered to be one of the most severe design parameters. This paper discusses the engine vibration characteristics, and the acquisition of extensive field vibration data on the diesel engine under operating conditions. The data is then used to develop life cycle vibration qualification test profiles that can be applied with confidence in a laboratory environment to qualify engine-mounted equipment. The intent is to validate a product's ability to survive under worst case, extended service on-engine conditions. This paper describes the procedures and approaches used to achieve those goals, and provides developed profile examples and test results

  19. The Observatory as Laboratory: Spectral Analysis at Mount Wilson Observatory

    Science.gov (United States)

    Brashear, Ronald

    2018-01-01

    This paper will discuss the seminal changes in astronomical research practices made at the Mount Wilson Observatory in the early twentieth century by George Ellery Hale and his staff. Hale’s desire to set the agenda for solar and stellar astronomical research is often described in terms of his new telescopes, primarily the solar tower observatories and the 60- and 100-inch telescopes on Mount Wilson. This paper will focus more on the ancillary but no less critical parts of Hale’s research mission: the establishment of associated “physical” laboratories as part of the observatory complex where observational spectral data could be quickly compared with spectra obtained using specialized laboratory equipment. Hale built a spectroscopic laboratory on the mountain and a more elaborate physical laboratory in Pasadena and staffed it with highly trained physicists, not classically trained astronomers. The success of Hale’s vision for an astronomical observatory quickly made the Carnegie Institution’s Mount Wilson Observatory one of the most important astrophysical research centers in the world.

  20. Design and functional tests of the Euclid grism mount

    Science.gov (United States)

    Rossin, Ch.; Grange, R.; Caillat, A.; Costille, A.; Sanchez, P.; Ceria, W.

    2017-11-01

    The Euclid mission selected by ESA in the Cosmic Vision program is dedicated to understand dark energy and dark matter. One of the probes based on detection of Baryonic Acoustic Oscillations required the redshift of millions of galaxies. This massive spectroscopic survey relies on the Near Infrared SpectroPhotometer (NISP) using grism in slitless mode. In this Euclid NISP context, we designed a cryogenic mount for the four grisms of the spectroscopic channel. This mount has to maintain optical performances and alignment at the cryogenic temperature of 120K and to survive launch vibrations. Due to a very small mass and volume budget allowed in the Grism Wheel Assembly our design relies on a weight relief Invar ring glued to the grism by tangential flexures. Tangential flexures have the advantage of small height but the drawback of less decoupling capabilities than bipods. We will present the design of the mount and the integration and functional tests to stay within the 60 nm RMS transmitted wavefront error budget allowed to the grism.

  1. Shaded Relief with Height as Color, Mount Meru, Tanzania

    Science.gov (United States)

    2002-01-01

    Mount Meru is an active volcano located just 70 kilometers (44 miles) west of Mount Kilimanjaro. It reaches 4,566 meters (14,978 feet) in height but has lost much of its bulk due to an eastward volcanic blast sometime in its distant past, perhaps similar to the eruption of Mount Saint Helens in Washington State in 1980. Mount Meru most recently had a minor eruption about a century ago. The several small cones and craters seen in the vicinity probably reflect numerous episodes of volcanic activity. Mount Meru is the topographic centerpiece of Arusha National Park. Its fertile slopes rise above the surrounding savanna and support a forest that hosts diverse wildlife, including nearly 400 species of birds, and also monkeys and leopards.Two visualization methods were combined to produce this image: shading and color coding of topographic height. The shade image was derived by computing topographic slope in the north-south direction. Northern slopes appear bright and southern slopes appear dark, as would be the case at noon at this latitude in June. Color coding is directly related to topographic height, with green at the lower elevations, rising through yellow, red, and magenta, to blue and white at the highest elevations.Elevation data used in this image was acquired by the Shuttle Radar Topography Mission (SRTM) aboard the Space Shuttle Endeavour, launched on Feb. 11, 2000. SRTM used the same radar instrument that comprised the Spaceborne Imaging Radar-C/X-Band Synthetic Aperture Radar (SIR-C/X-SAR) that flew twice on the Space Shuttle Endeavour in 1994. SRTM was designed to collect 3-D measurements of the Earth's surface. To collect the 3-D data, engineers added a 60-meter (approximately 200-foot) mast, installed additional C-band and X-band antennas, and improved tracking and navigation devices. The mission is a cooperative project between NASA, the National Imagery and Mapping Agency (NIMA) of the U.S. Department of Defense and the German and Italian space

  2. A Novel Cellular Handset Design for an Enhanced Antenna Performance and a Reduced SAR in the Human Head

    Directory of Open Access Journals (Sweden)

    Salah I. Al-Mously

    2008-01-01

    Full Text Available This paper presents a novel cellular handset design with a bottom-mounted short loaded-whip antenna. This new handset design is modeled and simulated using a finite difference time-domain (FDTD-based platform SEMCAD. The proposed handset is based on a current commercially available bar-phone type with a curvature shape, keypad positioned above the screen, and top-mounted antenna. The specific absorption rates (SARs are determined computationally in the specific anthropomorphic mannequin (SAM and anatomically correct model of a human head when exposed to the EM-field radiation of the proposed cellular handset and the handset with top-mounted antenna. The two cellular handsets are simulated to operate at both GSM standards, 900 MHz as well as 1800 MHz, having different antenna dimensions and intput power of 0.6 W and 0.125 W, respectively. The proposed human hand holding the two handset models is a semirealistic hand model consists of three tissues: skin, muscle, and bone. The simulations are conducted with handset positions based on the IEEE standard 1528-2003. The results show that the proposed handset has a significant improvement of antenna efficiency when it is hand-held close to head, as compared with the handset of top-mounted antenna. Also, the results show that a significant reduction of the induced SAR in the human head-tissues can be achieved with the proposed handset.

  3. Development of a Double Glass Mounting Method Using Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) and its Evaluation for Permanent Mounting of Small Nematodes.

    Science.gov (United States)

    Zahabiun, Farzaneh; Sadjjadi, Seyed Mahmoud; Esfandiari, Farideh

    2015-01-01

    Permanent slide preparation of nematodes especially small ones is time consuming, difficult and they become scarious margins. Regarding this problem, a modified double glass mounting method was developed and compared with classic method. A total of 209 nematode samples from human and animal origin were fixed and stained with Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) followed by double glass mounting and classic dehydration method using Canada balsam as their mounting media. The slides were evaluated in different dates and times, more than four years. Different photos were made with different magnification during the evaluation time. The double glass mounting method was stable during this time and comparable with classic method. There were no changes in morphologic structures of nematodes using double glass mounting method with well-defined and clear differentiation between different organs of nematodes in this method. Using this method is cost effective and fast for mounting of small nematodes comparing to classic method.

  4. Representation of heading direction in far and near head space

    NARCIS (Netherlands)

    Poljac, E.; Berg, A.V. van den

    2003-01-01

    Manipulation of objects around the head requires an accurate and stable internal representation of their locations in space, also during movements such as that of the eye or head. For far space, the representation of visual stimuli for goal-directed arm movements relies on retinal updating, if eye

  5. [Population structure and regeneration strategy of relict deciduous broadleaved trees on Mount Tianmu, Zhejiang Province, China.

    Science.gov (United States)

    Shang, Kan Kan; Chen, Bo; Da, Liang Jun

    2018-02-01

    The population structure, regeneration ways and spatial relationships of six relict deci-duous broadleaved trees were examined based on community investigation on Mount Tianmu, East China. The results showed that relict deciduous broadleaved trees had a strong ability of vegetative reproduction and their population structure was generally belonged to intermittent type. Some relict species such as Cyclocarya paliurus and Liquidamb aracalycina regenerated discontinuously at appropriate sites via long-distance diffusion. Some species such as Emmenoptery henryi and Euptelea pleiospermum regenerated discontinuously around mature trees due to habitat limitation and frequent disturbance. After occupying forest gaps by seedling regeneration, C. paliurus, L. acalycina, Nyssasinensis and Liquidambar formosana could recruit and form multi-stemmed individuals by their inherent sprouting ability at relatively stable sites such as crest slope and side slope. At riverbed, valley slope and head hollow, recognized as unstable habitats, Emmenopterys henryi, E. pleiospermum, and L. formosana could also recruit by strong sprouting ability due to sparse seedlings and individual loss incurred by disturbance. Therefore, the relict deciduous broadleaved trees could be classified into two ecological species groups (repairment species for forest gap and supplement species for special habitat) based on spatial distribution and strategy of regeneration and competition. We suggested that the protection of special habitats of their communities should be strengthened.

  6. Exposure setups for laboratory animals and volunteer studies using body-mounted antennas

    International Nuclear Information System (INIS)

    Bahr, A.; Adami, C.; Bolz, T.; Rennings, A.; Dorn, H.; Ruettiger, L.

    2007-01-01

    For two different in vivo exposure setups body-mounted antenna systems have been designed. The first setup is designed for investigation of volunteers during simulated mobile phone usage. The setup consists of a dual-band antenna for GSM/WCDMA with enhanced carrying properties, which enables exposure for at least 8 h a day. The 10 g averaged localised SAR - normalised to an antenna input power of 1 W - measured in the flat phantom area of the SAM phantom amounts to 7.82 mW g -1 (900 MHz) and 10.98 mW g -1 (1966 MHz). The second exposure setup is used for a laboratory behavioural study on rats. The design goal was a localised, well-defined SAR distribution inside the animals' heads at 900 MHz. To fulfil the biological requirements, a loop antenna was developed. For tissues around the ears, a localised SAR value of 50.12 W kg -1 averaged over a mass of 2.2 g for an antenna input power of 1 W is obtained. (authors)

  7. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    In our cases of acute and subacute subdural hematoma, the use of CT was evaluated. In our department of surgery, acute subdural hematoma was found in 46 of 388 patients of head trauma who underwent CT. Acute subdural hematoma, like epidural hematoma was usually visualized as a high-density area along the cranial inner table, and this was easily differenciated from epidural hematoma because of difference in shape from the other. The picture of acute subdural hematoma was occasionally confused with that of intracerebral hematoma or cerebral contusion. Single use of CT does not differenciate subacute subdural hematoma from chronic subdural hematoma. However, CT usually visualized acute hematoma as a high-density area, showing the extent of hematoma. Comparison of the thickness of hematoma with the axis deviation of the median part such as the 3rd cerebral ventricle suggested severity of cerebral edema. CT also revealed bilateral or multiple lesions of cerebral contusion or intracerebral hematoma. (Ueda, J.)

  8. Chryse 'Alien Head'

    Science.gov (United States)

    2005-01-01

    26 January 2004 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows an impact crater in Chryse Planitia, not too far from the Viking 1 lander site, that to seems to resemble a bug-eyed head. The two odd depressions at the north end of the crater (the 'eyes') may have formed by wind or water erosion. This region has been modified by both processes, with water action occurring in the distant past via floods that poured across western Chryse Planitia from Maja Valles, and wind action common occurrence in more recent history. This crater is located near 22.5oN, 47.9oW. The 150 meter scale bar is about 164 yards long. Sunlight illuminates the scene from the left/lower left.

  9. Lower head failure analysis

    International Nuclear Information System (INIS)

    Rempe, J.L.; Thinnes, G.L.; Allison, C.M.; Cronenberg, A.W.

    1991-01-01

    The US Nuclear Regulatory Commission is sponsoring a lower vessel head research program to investigate plausible modes of reactor vessel failure in order to determine (a) which modes have the greatest likelihood of occurrence during a severe accident and (b) the range of core debris and accident conditions that lead to these failures. This paper presents the methodology and preliminary results of an investigation of reactor designs and thermodynamic conditions using analytic closed-form approximations to assess the important governing parameters in non-dimensional form. Preliminary results illustrate the importance of vessel and tube geometrical parameters, material properties, and external boundary conditions on predicting vessel failure. Thermal analyses indicate that steady-state temperature distributions will occur in the vessel within several hours, although the exact time is dependent upon vessel thickness. In-vessel tube failure is governed by the tube-to-debris mass ratio within the lower head, where most penetrations are predicted to fail if surrounded by molten debris. Melt penetration distance is dependent upon the effective flow diameter of the tube. Molten debris is predicted to penetrate through tubes with a larger effective flow diameter, such as a boiling water reactor (BWR) drain nozzle. Ex-vessel tube failure for depressurized reactor vessels is predicted to be more likely for a BWR drain nozzle penetration because of its larger effective diameter. At high pressures (between ∼0.1 MPa and ∼12 MPa) ex-vessel tube rupture becomes a dominant failure mechanism, although tube ejection dominates control rod guide tube failure at lower temperatures. However, tube ejection and tube rupture predictions are sensitive to the vessel and tube radial gap size and material coefficients of thermal expansion

  10. Fractionation schedules for cancers of the head and neck

    International Nuclear Information System (INIS)

    Harari, Paul M.

    1995-01-01

    Purpose/Objective: This refresher course reviews current research activity and treatment results in the field of radiation therapy fractionation. The presentation emphasizes worldwide studies of altered fractionation, highlighting head and neck cancer as the primary teaching model. Basic radiobiological principles guiding the development of altered fractionation regimens, and advancing the understanding of fractionation effects on normal and tumor tissue are reviewed. A 'standard' prescription of 2 Gy x 35 fractions = 70 Gy may not provide the optimal balance between primary tumor control and late normal tissue effects for all patients with squamous cell carcinoma of the head and neck. The last decade has witnessed the treatment of thousands of head and neck cancer patients with curative radiotherapy using altered fractination schedules designed to improve overall treatment results. Although the number of different fractionation regimens currently being investigated continues to increase, the common guiding principles behind their design are relatively simple. Common fractionation terminology (i.e., accelerated hyperfractionation) will be reviewed, as well as a brief summary of radiobiological concepts pertaining to tumor potential doubling time, tumor proliferation kinetics, overall treatment time and fraction size-dependence of acute and late tissue effects. Several well known head and neck fractionation schedules from around the world (Manchester Christie Hospital-United Kingdom, Princess Margaret Hospital-Canada, Massachusetts General Hospital-USA, MD Anderson Hospital-USA, University of Florida-USA, Mount Vernon Hospital CHART-United Kingdom, RTOG and EORTC trials-USA and Europe) will be summarized with regard to design-rationale, treatment technique and results. The design of several current cooperative group trials investigating altered head and neck fractionation will be presented, as well as concepts prompting the pilot evaluation of several brand new

  11. 76 FR 2370 - Mount Storm Hydro, LLC; Notice of Preliminary Permit Application Accepted for Filing and...

    Science.gov (United States)

    2011-01-13

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 13863-000] Mount Storm..., Motions To Intervene, and Competing Applications January 6, 2011. On October 14, 2010, Mount Storm Hydro... (FPA), proposing to study the feasibility of the Mount Storm Pumped Storage Project to be located near...

  12. A Low-Cost Part-Task Flight Training System: An Application of a Head Mounted Display

    Science.gov (United States)

    1990-12-01

    architecture. The task at hand was to develop a software emulation libary that would emulate the function calls used within the Flight and Dog programs. This...represented in two hexadecimal digits for each color. The format of the packed long integer looks like aaggbbrr with each color value representing a...Western Digital ethernet card as the cheapest compatible card available. Good fortune arrived, as I was calling to order the card, I saw an unused card

  13. Clinical introduction of a linac head-mounted 2D detector array based quality assurance system in head and neck IMRT

    NARCIS (Netherlands)

    Korevaar, Erik W.; Wauben, David J. L.; van der Hulst, Peter C.; Langendijk, Johannes A.; van t Veld, Aart

    Background and purpose: IMRT QA is commonly performed in a phantom geometry but the clinical interpretation of the results in a 2D phantom plane is difficult. The main objective of our work is to move from film measurement based QA to 3D dose reconstruction in a patient CT scan. In principle, this

  14. In search of rules behind environmental framing; the case of head pitch.

    Science.gov (United States)

    Wilson, Gwendoline Ixia; Norman, Brad; Walker, James; Williams, Hannah J; Holton, M D; Clarke, D; Wilson, Rory P

    2015-01-01

    Whether, and how, animals move requires them to assess their environment to determine the most appropriate action and trajectory, although the precise way the environment is scanned has been little studied. We hypothesized that head attitude, which effectively frames the environment for the eyes, and the way it changes over time, would be modulated by the environment. To test this, we used a head-mounted device (Human-Interfaced Personal Observation platform - HIPOP) on people moving through three different environments; a botanical garden ('green' space), a reef ('blue' space), and a featureless corridor, to examine if head movement in the vertical axis differed between environments. Template matching was used to identify and quantify distinct behaviours. The data on head pitch from all subjects and environments over time showed essentially continuous clear waveforms with varying amplitude and wavelength. There were three stylised behaviours consisting of smooth, regular peaks and troughs in head pitch angle and variable length fixations during which the head pitch remained constant. These three behaviours accounted for ca. 40 % of the total time, with irregular head pitch changes accounting for the rest. There were differences in rates of manifestation of behaviour according to environment as well as environmentally different head pitch values of peaks, troughs and fixations. Finally, although there was considerable variation in head pitch angles, the peak and trough values bounded most of the variation in the fixation pitch values. It is suggested that the constant waveforms in head pitch serve to inform people about their environment, providing a scanning mechanism. Particular emphasis to certain sectors is manifest within the peak and trough limits and these appear modulated by the distribution of the points where fixation, interpreted as being due to objects of interest, occurs. This behaviour explains how animals allocate processing resources to the

  15. A novel device for head gesture measurement system in combination with eye-controlled human machine interface

    Science.gov (United States)

    Lin, Chern-Sheng; Ho, Chien-Wa; Chang, Kai-Chieh; Hung, San-Shan; Shei, Hung-Jung; Yeh, Mau-Shiun

    2006-06-01

    This study describes the design and combination of an eye-controlled and a head-controlled human-machine interface system. This system is a highly effective human-machine interface, detecting head movement by changing positions and numbers of light sources on the head. When the users utilize the head-mounted display to browse a computer screen, the system will catch the images of the user's eyes with CCD cameras, which can also measure the angle and position of the light sources. In the eye-tracking system, the program in the computer will locate each center point of the pupils in the images, and record the information on moving traces and pupil diameters. In the head gesture measurement system, the user wears a double-source eyeglass frame, so the system catches images of the user's head by using a CCD camera in front of the user. The computer program will locate the center point of the head, transferring it to the screen coordinates, and then the user can control the cursor by head motions. We combine the eye-controlled and head-controlled human-machine interface system for the virtual reality applications.

  16. Liberating the Temple Mount: apocalyptic tendencies among Jewish temple activists

    Directory of Open Access Journals (Sweden)

    Maria Leppäkari

    2006-01-01

    Full Text Available Every now and then instances of violence are played out at the Temple Mount area in Jerusalem, also known as the Haram-esh-sharif. Some of the cases are referred to as results of the so-called ‘Jerusalem syndrome’, incidents when individuals’ manifestations of pre-existing psychopathology culminate in violent actions. Israeli psychiatrists and others have treated such incidents as examples of when peoples’ expectations of a heavenly Jerusalem collide with the very earthly reality in the city. For some people, such encounters may create anxiety that may threaten the victim’s very sanity. In such situations, an apocalyptic mission may become the only way for them to cope with the situation at hand. But the Temple Mount does not only attract lone-acting individuals, it also attracts organized groups who refer to the very spot as an important identity marker. In this article, the author draws on her field research material and interviews with Jewish Third Temple activists in Jerusalem collected on and off between 1998 and 2004. Here Yehuda Etzion’s, Gershon Salomon’s and Yoel Lerner’s theology and activities are studied in light of apocalyptic representations, and how these are expressed in relation to religious longing for the Third Temple in the light of the Gaza withdrawal. Not all those who are engaged in endtime scenarios act upon their visions. In Jerusalem, there have been, and still are, several religious-political groups that more or less ritually perambulate the Temple Mount area.

  17. Stereotactic Body Radiotherapy for Head and Neck Tumors

    Science.gov (United States)

    2016-04-18

    Squamous Cell Carcinoma of the Head and Neck; Nasopharyngeal Carcinoma; Salivary Gland Cancer; Head and Neck Sarcoma; Paraganglioma of Head and Neck; Chordoma of Head and Neck; Chondrosarcoma of Head and Neck; Angiofibroma of Head and Neck

  18. Latency requirements for head-worn display S/EVS applications

    Science.gov (United States)

    Bailey, Randall E.; Arthur, Jarvis J., III; Williams, Steven P.

    2004-08-01

    NASA's Aviation Safety Program, Synthetic Vision Systems Project is conducting research in advanced flight deck concepts, such as Synthetic/Enhanced Vision Systems (S/EVS), for commercial and business aircraft. An emerging thrust in this activity is the development of spatially-integrated, large field-of-regard information display systems. Head-worn or helmet-mounted display systems are being proposed as one method in which to meet this objective. System delays or latencies inherent to spatially-integrated, head-worn displays critically influence the display utility, usability, and acceptability. Research results from three different, yet similar technical areas - flight control, flight simulation, and virtual reality - are collectively assembled in this paper to create a global perspective of delay or latency effects in head-worn or helmet-mounted display systems. Consistent definitions and measurement techniques are proposed herein for universal application and latency requirements for Head-Worn Display S/EVS applications are drafted. Future research areas are defined.

  19. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Groitl, Felix, E-mail: felix.groitl@psi.ch [Laboratory for Quantum Magnetism, École Polytechnique Fédérale de Lausanne, 1015 Lausanne (Switzerland); Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Bartkowiak, Marek [Laboratory for Scientific Developments and Novel Materials, Paul Scherrer Institut, 5232 Villigen (Switzerland); Bergmann, Ryan M. [Division Large Research Facilities, Paul Scherrer Institut, 5232 Villigen (Switzerland); Birk, Jonas Okkels [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Department of Physics, Technical University of Denmark (DTU), 2800 Kgs. Lyngby (Denmark); Markó, Márton [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Wigner Research Centre for Physics, Neutron Spectroscopy Department, 1525 Budapest (Hungary); Bollhalder, Alex; Graf, Dieter [Laboratory for Scientific Developments and Novel Materials, Paul Scherrer Institut, 5232 Villigen (Switzerland); Niedermayer, Christof [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Rüegg, Christian [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Department of Quantum Matter Physics, University of Geneva, 1211 Geneva (Switzerland); Rønnow, Henrik M. [Laboratory for Quantum Magnetism, École Polytechnique Fédérale de Lausanne, 1015 Lausanne (Switzerland); Niels Bohr Institute, University of Copenhagen, 2100 Copenhagen (Denmark)

    2017-06-21

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each other where the neutrons have to pass through the bonding compound of the different analyzer crystals. The different methods, namely screws, shellac, indium soldering and clips, have been evaluated with regards to background, transmission, cooling, activation and handling. The results presented here will give valuable input for future CAMEA-type spectrometers currently planned and designed at various neutron sources.

  20. Cognitive considerations for helmet-mounted display design

    Science.gov (United States)

    Francis, Gregory; Rash, Clarence E.

    2010-04-01

    Helmet-mounted displays (HMDs) are designed as a tool to increase performance. To achieve this, there must be an accurate transfer of information from the HMD to the user. Ideally, an HMD would be designed to accommodate the abilities and limitations of users' cognitive processes. It is not enough for the information (whether visual, auditory, or tactual) to be displayed; the information must be perceived, attended, remembered, and organized in a way that guides appropriate decision-making, judgment, and action. Following a general overview, specific subtopics of cognition, including perception, attention, memory, knowledge, decision-making, and problem solving are explored within the context of HMDs.

  1. Mount Baker lahars and debris flows, ancient, modern, and future

    Science.gov (United States)

    Tucker, David S; Scott, Kevin M.; Grossman, Eric E.; Linneman, Scott

    2014-01-01

    The Middle Fork Nooksack River drains the southwestern slopes of the active Mount Baker stratovolcano in northwest Washington State. The river enters Bellingham Bay at a growing delta 98 km to the west. Various types of debris flows have descended the river, generated by volcano collapse or eruption (lahars), glacial outburst floods, and moraine landslides. Initial deposition of sediment during debris flows occurs on the order of minutes to a few hours. Long-lasting, down-valley transport of sediment, all the way to the delta, occurs over a period of decades, and affects fish habitat, flood risk, gravel mining, and drinking water.

  2. Kinematic mounting systems for NSLS beamlines and experiments

    International Nuclear Information System (INIS)

    Oversluizen, T.; Stoeber, W.; Johnson, E.D.

    1991-01-01

    Methods for kinematically mounting equipment are well established, but applications at synchrotron radiation facilities are subject to constraints not always encountered in more traditional laboratory settings. Independent position adjustment of beamline components can have significant benefits in terms of minimizing time spent aligning, and maximizing time spent acquiring data. In this paper, we use examples taken from beamlines at the NSLS to demonstrate approaches for optimization of the reproducibility, stability, excursion, and set-up time for various situations. From our experience, we extract general principles which we hope will be useful for workers at other synchrotron radiation facilities. 7 refs., 4 figs

  3. Digital cross-mounting: A new opportunity in prosthetic dentistry.

    Science.gov (United States)

    Venezia, Pietro; Torsello, Ferruccio; D'Amato, Salvatore; Cavalcanti, Raffaele

    2017-01-01

    The prosthodontic management of complex rehabilitations requires several stages of treatment including one or more provisional restorations. The design and adjustments of the provisional are made to achieve an optimal functional and esthetic outcome for the patient. However, the adjustments needed are both time and cost consuming. Therefore, once a satisfactory provisional is made, the information should not be lost during the following stages of treatment. The purpose of this clinical case is to illustrate "digital cross-mounting," a procedure used to precisely transfer information from the provisional to the final fixed rehabilitation in a digital workflow.

  4. Active Engine Mounting Control Algorithm Using Neural Network

    Directory of Open Access Journals (Sweden)

    Fadly Jashi Darsivan

    2009-01-01

    Full Text Available This paper proposes the application of neural network as a controller to isolate engine vibration in an active engine mounting system. It has been shown that the NARMA-L2 neurocontroller has the ability to reject disturbances from a plant. The disturbance is assumed to be both impulse and sinusoidal disturbances that are induced by the engine. The performance of the neural network controller is compared with conventional PD and PID controllers tuned using Ziegler-Nichols. From the result simulated the neural network controller has shown better ability to isolate the engine vibration than the conventional controllers.

  5. Cooling performance of a notebook PC mounted with heat spreader

    Energy Technology Data Exchange (ETDEWEB)

    Noh, H.K. [Electronics and Telecommunications Research Institute, Taejeon (Korea); Lim, K.B. [Hanbat National University, Taejeon (Korea); Park, M.H. [Korea Power Engineering Company (Korea)

    2001-06-01

    Parametric study to investigate the cooling performance of a notebook PC mounted with heat spreader has been numerically performed. Two case of air-blowing and air-exhaust at inlet were tested. The cooling effect on parameters such as, inlet velocities in the cases of air-blowing and air-exhaust, materials of heat spreader, and CPU powers were simulated for two cases. Cooling performance in the case of air-blowing was better than the case of air-exhaust. (author). 9 refs., 7 figs., 5 tabs.

  6. Development of a segmented grating mount system for FIREX-1

    International Nuclear Information System (INIS)

    Ezaki, Y; Tabata, M; Kihara, M; Horiuchi, Y; Endo, M; Jitsuno, T

    2008-01-01

    A mount system for segmented meter-sized gratings has been developed, which has a high precision grating support mechanism and drive mechanism to minimize both deformation of the optical surfaces and misalignments in setting a segmented grating for obtaining sufficient performance of the pulse compressor. From analytical calculations, deformation of the grating surface is less than 1/20 lambda RMS and the estimated drive resolution for piston and tilt drive of the segmented grating is 1/20 lambda, which are both compliant with the requirements for the rear-end subsystem of FIREX-1

  7. User's guide to designing and mounting lenses and mirrors

    International Nuclear Information System (INIS)

    Kowalskie, B.J.

    1978-01-01

    The guidebook is a practitioner-oriented supplement to standard texts in optics and mechanical engineering. It reflects practical experience with the oftentimes troublesome aspects of effectively integrating optical components with mechanical hardware. Accordingly, its focus is on the techniques, assumptions, and levels of design sophistication needed for a wide variety of sizes and optical surface quality levels. It is intended to be a primer for engineers, designers, and draftsmen already familiar with some of the problems encountered in mounting optical components and who are responsible for developing components for high-energy laser systems

  8. The misalignment angle in vessel-mounted ADCP

    Directory of Open Access Journals (Sweden)

    Robert Osinski

    2000-09-01

    Full Text Available A description of the misalignment angle and the consequences if it occurs is given. It is shown that because of gyrocompass errors, the misalignment angle error a has to be computed for each cruise. A simple method of calibrating the acoustic Doppler current profiler (ADCP mounted on a vessel has been devised by fitting the cosinusoidal function. This is a post-processing method, suitable for calibrating previously collected data. Nevertheless, because of ADCP's constructional peculiarities, the procedure must be repeated for each cruise.

  9. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    International Nuclear Information System (INIS)

    Groitl, Felix; Bartkowiak, Marek; Bergmann, Ryan M.; Birk, Jonas Okkels; Markó, Márton; Bollhalder, Alex; Graf, Dieter; Niedermayer, Christof; Rüegg, Christian; Rønnow, Henrik M.

    2017-01-01

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each other where the neutrons have to pass through the bonding compound of the different analyzer crystals. The different methods, namely screws, shellac, indium soldering and clips, have been evaluated with regards to background, transmission, cooling, activation and handling. The results presented here will give valuable input for future CAMEA-type spectrometers currently planned and designed at various neutron sources.

  10. Turbidity Current Head Mixing

    Science.gov (United States)

    Hernandez, David; Sanchez, Miguel Angel; Medina, Pablo

    2010-05-01

    A laboratory experimental set - up for studying the behaviour of sediment in presence of a turbulent field with zero mean flow is compared with the behaviour of turbidity currents [1] . Particular interest is shown on the initiation of sediment motion and in the sediment lift - off. The behaviour of the turbidity current in a flat ground is compared with the zero mean flow oscilating grid generated turbulence as when wave flow lifts off suspended sediments [2,3]. Some examples of the results obtained with this set-up relating the height of the head of the turbidity current to the equilibrium level of stirred lutoclines are shown. A turbulent velocity u' lower than that estimated by the Shield diagram is required to start sediment motion. The minimum u' required to start sediment lift - off, is a function of sediment size, cohesivity and resting time. The lutocline height depends on u', and the vorticity at the lutocline seems constant for a fixed sediment size [1,3]. Combining grid stirring and turbidty current head shapes analyzed by means of advanced image analysis, sediment vertical fluxes and settling speeds can be measured [4,5]. [1] D. Hernandez Turbulent structure of turbidity currents and sediment transport Ms Thesis ETSECCPB, UPC. Barcelona 2009. [2] A. Sánchez-Arcilla; A. Rodríguez; J.C. Santás; J.M. Redondo; V. Gracia; R. K'Osyan; S. Kuznetsov; C. Mösso. Delta'96 Surf-zone and nearshore measurements at the Ebro Delta. A: International Conference on Coastal Research through large Scale Experiments (Coastal Dynamics '97). University of Plymouth, 1997, p. 186-187. [3] P. Medina, M. A. Sánchez and J. M. Redondo. Grid stirred turbulence: applications to the initiation of sediment motion and lift-off studies Physics and Chemistry of the Earth, Part B: Hydrology, Oceans and Atmosphere. 26, Issue 4, 2001, Pages 299-304 [4] M.O. Bezerra, M. Diez, C. Medeiros, A. Rodriguez, E. Bahia., A. Sanchez-Arcilla and J.M. Redondo. Study on the influence of waves on

  11. Preparation of Samples for Leaf Architecture Studies, A Method for Mounting Cleared Leaves

    Directory of Open Access Journals (Sweden)

    Alejandra Vasco

    2014-09-01

    Full Text Available Premise of the study: Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. Methods and Results: Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. Conclusions: The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration.

  12. Preparation of samples for leaf architecture studies, a method for mounting cleared leaves.

    Science.gov (United States)

    Vasco, Alejandra; Thadeo, Marcela; Conover, Margaret; Daly, Douglas C

    2014-09-01

    Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. • Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. • The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration.

  13. Preparation of samples for leaf architecture studies, a method for mounting cleared leaves1

    Science.gov (United States)

    Vasco, Alejandra; Thadeo, Marcela; Conover, Margaret; Daly, Douglas C.

    2014-01-01

    • Premise of the study: Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. • Methods and Results: Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. • Conclusions: The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration. PMID:25225627

  14. Mounting Systems for Structural Members, Fastening Assemblies Thereof, and Vibration Isolation Systems Including the Same

    Science.gov (United States)

    Young, Ken (Inventor); Hindle, Timothy (Inventor); Barber, Tim Daniel (Inventor)

    2016-01-01

    Mounting systems for structural members, fastening assemblies thereof, and vibration isolation systems including the same are provided. Mounting systems comprise a pair of mounting brackets, each clamped against a fastening assembly forming a mounting assembly. Fastening assemblies comprise a spherical rod end comprising a spherical member having a through opening and an integrally threaded shaft, first and second seating members on opposite sides of the spherical member and each having a through opening that is substantially coaxial with the spherical member through opening, and a partially threaded fastener that threadably engages each mounting bracket forming the mounting assembly. Structural members have axial end portions, each releasably coupled to a mounting bracket by the integrally threaded shaft. Axial end portions are threaded in opposite directions for permitting structural member rotation to adjust a length thereof to a substantially zero strain position. Structural members may be vibration isolator struts in vibration isolation systems.

  15. Femoral head necrosis; Hueftkopfnekrose

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, J.; Scheurecker, G.; Scheurecker, A.; Stoeger, A.; Huber, A. [Roentgeninstitut am Schillerpark, Linz (Austria); Hofmann, S. [Orthopaedisches Landeskrankenhaus Stolzalpe (Austria)

    2009-05-15

    The epidemiology and pathohistogenesis of avascular femoral head necrosis has still not been clarified in detail. Because the course of the disease runs in stages and over a long time period nearly always culminates in the necessity for a total hip prosthesis, an exact radiological evaluation is of paramount importance for the treatment. There is a need for a common staging system to enable comparison of different therapy concepts and especially their long-term results. In this article the ARCO staging system is described in full detail, which includes all radiological modalities as well as histopathological alterations. (orig.) [German] Bei der avaskulaeren Femurkopfnekrose handelt es sich um ein Krankheitsbild, dessen Ursachen noch immer nicht vollstaendig geklaert sind. Da die Erkrankung stadienhaft verlaeuft und ueber einen laengeren Zeitraum betrachtet nahezu immer in einem prothetischen Hueftersatz muendet, ist eine genaue radiologische Abklaerung fuer die Behandlung von enormer Bedeutung. Um Langzeiterfolge verschiedener Therapiekonzepte vergleichen zu koennen, sind eine exakte Beschreibung und darauf basierend die Verwendung einer einheitlichen Stadieneinteilung wuenschenswert. In der vorliegenden Arbeit wird die ARCO-Stadieneinteilung im Detail beschrieben, die alle bildgebenden Methoden beruecksichtigt und histopathologische Veraenderungen mit einbezieht. (orig.)

  16. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    It has been said that chronic subdural hematoma cannot be diagnosed by CT. In our cases, CT was used, and the results were described. According to the density of the picture, CT findings of chronic subdural hematoma could be classified into 3 types, those of higher density than that of the cerebral paranchyma, those of isodensity, and those of lower density than that of the cerebral parenchyma. The difference among them appeared to be due to variation in the fluid in hematoma, especially that in hemoglobin concentration. Chronic subdural hematoma was found in 27 of 388 cases of head trauma in which CT was undertaken in our department of surgery for last 2 years. It is difficult to differenciate this disease from subdural edema or subarachnoideal retention of the cerebrospinal fluid. In many cases, use of contrast medium added no change to the CT picture. Cerebral angiography is necessary for definite diagnosis of the disease. Chronic subdural hematoma gives more varieties of findings than other intracranial hematomas. However, if the film is very carefully read, CT is still useful for diagnosing this disease in spite of initially remarked difficulties. (Ueda, J.)

  17. Human papilloma virus: a new risk factor in a subset of head and neck cancers.

    Science.gov (United States)

    Bisht, Manisha; Bist, Sampan Singh

    2011-01-01

    Head and neck cancer is the sixth most common malignancy worldwide. Tobacco smoking and alcohol consumption are two well known behavioral risk factors associated with head and neck cancer. Recently, evidence is mounting that infection with human papilloma virus, most commonly human papilloma virus-16 is responsible for a subset of head and neck squamous cell carcinoma especially tumors of tonsillar origin. The molecular pathway used by human papilloma virus to trigger malignant transformation of tissue is different from that of other well known risk factors, i.e. smoking and alcohol, associated with squamous cell carcinoma. Apparently, these subsets of patients with human papilloma virus positive tumor are more likely to have a better prognosis than human papilloma virus negative tumor. Considering this fact, the human papilloma virus infection should be determined in all oropharyngeal cancers since it can have a major impact on the decision making process of the treatment.

  18. A Vehicle-mounted Crop Detector with Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Zhenjiang ZHONG

    2014-03-01

    Full Text Available In order to detect crop chlorophyll content in real-time, a new vehicle-mounted detector for measuring crop canopy spectral characteristics was developed. It was designed to work as a wireless sensor network with several optical sensor nodes and one control unit. All the optical sensor nodes were mounted on an on-board mechanical structure so that they could collect the canopy spectral data while in mobile condition. Each optical sensor node was designed to contain four optical channels, which allowed it work at the wavebands of 550, 650, 766 and 850 nm. The control unit included a PDA (Personal Digital Assistant device with a ZigBee wireless network coordinator and a GPRS module. It was used to receive, display, store all the data sent from optical sensor nodes and send data to the server through GPRS module. The calibration tests verified the stability of the wireless network and the measurement precision of the sensors. Both stationary and moving field experiments were also conducted in a winter wheat experimental field. Results showed that the correlation between chlorophyll content and vegetation index had high significance with the highest R2 of 0.6824. Those results showed the potential of the detector for field application.

  19. Qualification of engine-mounted components due to operational vibration

    International Nuclear Information System (INIS)

    Lee, B.J.; Bayat, A.

    1994-01-01

    The Emergency Diesel Generator (EDG) in a Nuclear Power Plant is considered to be an essential component of the plant for its safe operation. Failures of auxiliary components directly mounted on the EDG creates costly repairs, and compromises the engine's availability and reliability. Although IEEE-323 and Section III of the ASME code require addressing of safety-related components due to mechanically induced vibration, very few guidelines exist in the nuclear industry to show how this may be accounted for. Most engine vendors rely on the empirical experience data as the basis of their evaluation for vibration. Upgrade of engine controls, addition of monitoring components and other engine modifications require design and installation of new mechanical and electrical components to be mounted directly on the engine. This necessitates the evaluation of such components for engine-induced vibration which is considered to be one of the most severe design parameters. This paper presents a methodology to evaluate three categories of components; structural, mechanical, and electrical under engine vibration. The discussion for the characteristics and manipulation of engine vibration profile to be used for each component evaluation is also given. In addition, the suitability of analytical verses testing approaches is discussed for each category. An example application of the methodology is presented for a typical EDG which is currently undergoing major controls upgrade and monitoring modification

  20. Performance characteristics of solar air heater with surface mounted obstacles

    International Nuclear Information System (INIS)

    Bekele, Adisu; Mishra, Manish; Dutta, Sushanta

    2014-01-01

    Highlights: • Solar air heater with delta shaped obstacles have been studied. • Obstacle angle of incidence strongly affects the thermo-hydraulic performance. • Thermal performance of obstacle mounted collectors is superior to smooth collectors. • Thermo-hydraulic performance of the present SAH is higher than those in previous studies. - Abstract: The performance of conventional solar air heaters (SAHs) can be improved by providing obstacles on the heated wall (i.e. on the absorber plate). Experiments have been performed to collect heat transfer and flow-friction data from an air heater duct with delta-shaped obstacles mounted on the absorber surface and having an aspect ratio 6:1 resembling the conditions close to the solar air heaters. This study encompassed for the range of Reynolds number (Re) from 2100 to 30,000, relative obstacle height (e/H) from 0.25 to 0.75, relative obstacle longitudinal pitch (P l /e) from 3/2 to 11/2, relative obstacle transverse pitch (P t /b) from 1 to 7/3 and the angle of incidence (α) varied from 30° to 90°. The thermo-hydraulic performance characteristics of SAH have been compared with the previous published works and the optimum range of the geometries have been explored for the better performance of such air-heaters compared to the other designs of solar air heaters

  1. Sensor 17 Thermal Isolation Mounting Structure (TIMS) Design Improvements

    Energy Technology Data Exchange (ETDEWEB)

    Enstrom, K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-09-04

    The SENSOR 17 thermographic camera weighs approximately 0.5lbs, has a fundamental mode of 167 Hz, and experiences 0.75W of heat leakage in through the TIMS. The configuration, shown in Figure 1, is comprised of four 300 Series SST washers paired in tandem with P.E.I (Ultem 100) washers. The SENSOR 17 sensor is mounted to a 300 series stainless plate with A-shaped arms. The Plate can be assumed to be at ambient temperatures (≈293K) and the I.R. Mount needs to be cooled to 45K. It is attached to the tip of a cryocooler by a ‘cold strap’ and is assumed to be at the temperature of the cold-strap (≈45K). During flights SENSOR 17 experiences excitations at frequencies centered around 10-30Hz, 60Hz, and 120Hz from the aircraft flight environment. The temporal progression described below depicts the 1st Modal shape at the systems resonant frequency. This simulation indicates Modal articulation will cause a pitch rate of the camera with respect to the body axis of the airplane. This articulation shows up as flutter in the camera.

  2. Destruction and management of Mount Kenya`s forests

    Energy Technology Data Exchange (ETDEWEB)

    Bussmann, R.W. [Bayreuth Univ. (Germany). Fakultaet fuer Biologie, Chemie und Geowissenschaften

    1996-08-01

    This article presents data on the destruction of the montane forests on Mount Kenya. The material was obtained during field-work for a phytosociological study in 1992-1994. Special emphasis was given to the observation of regeneration patterns and succession cycles within the different forest communities, with regard to the impact of humans and big game. Although private tree planting is reducing the fuelwood deficit in Kenya, large parts of the 200 000 ha of Mount Kenya`s forests - the largest natural-forest area in the country - are heavily impacted by among other things illegal activities. The wet camphor forests of the south and southeast mountain slopes are being destroyed at an alarming speed, by large-scale selective logging of Ocotea usambarensis and marihuana cultivation. The drier Juniperus procera are also logged, but are even more endangered by the new settlement schemes. The large elephant population does not affect forest regeneration; whereas browsing and chaffing by buffaloes inhibits regeneration of the dry forests, and damages many trees. Suggestions are presented for better management of the forest resources. 12 refs, 1 fig

  3. Design features of SMART for barge mounted application

    International Nuclear Information System (INIS)

    Doo-Jeong Lee; Ju-Hyeon Yoon; Ju-Pyung Kim; Jong-In Kim; Moon-Hee Chang

    2000-01-01

    SMART is an integral reactor of 330 MWt capacity with passive safety features being developed for a wide range of applications including the barge mounted co-generation plant. Its design strives to combine the firmly-established commercial reactor design with new advanced technologies. Thus the use of the industry proven KOFA (Korea Optimized Fuel Assembly) based nuclear fuels is pursued while such radically new technologies as self-pressurizing pressurizer, helical once-through steam generators, and advanced control concepts are being developed. The safety of SMART centers around enhancing the inherent safety characteristics of the reactor and salient features include low core power density, integral arrangement to eliminate large break loss of coolant accident, etc. The progression of emergency situations into accidents is prevented with a number of advanced engineered safety features such as Passive Residual Heat Removal System, Passive Emergency Core Cooling System, Safeguard Vessel, Passive Containment Over-pressure Protection. This paper presents the status of current SMART development, characteristics of SMART safety systems and the possibility of SMART application to barge mounted environment. (author)

  4. Microwave Temperature Profiler Mounted in a Standard Airborne Research Canister

    Science.gov (United States)

    Mahoney, Michael J.; Denning, Richard F.; Fox, Jack

    2009-01-01

    Many atmospheric research aircraft use a standard canister design to mount instruments, as this significantly facilitates their electrical and mechanical integration and thereby reduces cost. Based on more than 30 years of airborne science experience with the Microwave Temperature Profiler (MTP), the MTP has been repackaged with state-of-the-art electronics and other design improvements to fly in one of these standard canisters. All of the controlling electronics are integrated on a single 4 5-in. (.10 13- cm) multi-layer PCB (printed circuit board) with surface-mount hardware. Improved circuit design, including a self-calibrating RTD (resistive temperature detector) multiplexer, was implemented in order to reduce the size and mass of the electronics while providing increased capability. A new microcontroller-based temperature controller board was designed, providing better control with fewer components. Five such boards are used to provide local control of the temperature in various areas of the instrument, improving radiometric performance. The new stepper motor has an embedded controller eliminating the need for a separate controller board. The reference target is heated to avoid possible emissivity (and hence calibration) changes due to moisture contamination in humid environments, as well as avoiding issues with ambient targets during ascent and descent. The radiometer is a double-sideband heterodyne receiver tuned sequentially to individual oxygen emission lines near 60 GHz, with the line selection and intermediate frequency bandwidths chosen to accommodate the altitude range of the aircraft and mission.

  5. Bottom-mounted control rod drive mechanism for KJRR

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Haeng; Kim, Sanghaun; Yoo, Yeon-Sik, E-mail: yooys@kaeri.re.kr; Cho, Yeong-Garp; Huh, Hyung; Lee, Hyokwang; Sun, Jong-Oh; Ryu, Jeong-Soo

    2016-04-15

    Highlights: • The basic design features and characteristics of the KJRR BMCRDM are described. • The similarities and differences of some research reactor CRDMs are compared. • The current status of the design and development of the CRDM is described. • The future plan of the qualification tests of the CRDM is summarized. - Abstract: The KIJANG research reactor (KJRR), which is currently being designed by Korea Atomic Energy Research Institute, is a pool type research reactor with 15 MW of thermal power. Contrary to the top-mounted control rod drive mechanism (CRDM), the main drive mechanism of the KJRR CRDM is located in a reactivity control mechanism room under the reactor pool bottom. Recently, we accomplished the design and development of a prototype CRDM. In this paper, we introduce the basic design concept of the bottom-mounted CRDM for KJRR, and compare the similarities and differences of some research reactor CRDMs. The current status of the prototype CRDM development based on a finite element analysis and experimental verification, and the future plan of the CRDM qualification tests, are both described.

  6. Beating-heart registration for organ-mounted robots.

    Science.gov (United States)

    Wood, Nathan A; Schwartzman, David; Passineau, Michael J; Moraca, Robert J; Zenati, Marco A; Riviere, Cameron N

    2018-03-06

    Organ-mounted robots address the problem of beating-heart surgery by adhering to the heart, passively providing a platform that approaches zero relative motion. Because of the quasi-periodic deformation of the heart due to heartbeat and respiration, registration must address not only spatial registration but also temporal registration. Motion data were collected in the porcine model in vivo (N = 6). Fourier series models of heart motion were developed. By comparing registrations generated using an iterative closest-point approach at different phases of respiration, the phase corresponding to minimum registration distance is identified. The spatiotemporal registration technique presented here reduces registration error by an average of 4.2 mm over the 6 trials, in comparison with a more simplistic static registration that merely averages out the physiological motion. An empirical metric for spatiotemporal registration of organ-mounted robots is defined and demonstrated using data from animal models in vivo. Copyright © 2018 John Wiley & Sons, Ltd.

  7. Will Mount Etna erupt before EGU General Assembly 2017?

    Science.gov (United States)

    Aloisi, Marco; Cannavo', Flavio; Palano, Mimmo

    2017-04-01

    Mount Etna has historically recorded a long and very various series of eruptions. The eruptions have mostly shown an episodic character, despite a near continuous supply of magma. In the last years, activity at Mount Etna seems to follow a recurrent pattern characterized by very similar "inflation/paroxysmal events/deflation" dynamic. The paroxysms occurred in December 2015 and May 2016, which involved the "Voragine" crater, can be considered among the most violent observed during the last two decades. These events showed high lava fountains, in the order of hundreds of meters in height, and eruption columns, several kilometres high. A new cycle, characterized by a clear similar inflation of the whole volcano edifice is currently underway. Here, we analyse these recent volcanic cycles and discuss about a) a possible upper bound for the inflation dynamic, above which a paroxysmal event occurs, b) the comparison of the models generating the considered lava fountains and c) a possible time-predictable model of the expected paroxysmal event.

  8. Community Exposure to Lahar Hazards from Mount Rainier, Washington

    Science.gov (United States)

    Wood, Nathan J.; Soulard, Christopher E.

    2009-01-01

    Geologic evidence of past events and inundation modeling of potential events suggest that lahars associated with Mount Rainier, Washington, are significant threats to downstream development. To mitigate potential impacts of future lahars and educate at-risk populations, officials need to understand how communities are vulnerable to these fast-moving debris flows and which individuals and communities may need assistance in preparing for and responding to an event. To support local risk-reduction planning for future Mount Rainier lahars, this study documents the variations among communities in King, Lewis, Pierce, and Thurston Counties in the amount and types of developed land, human populations, economic assets, and critical facilities in a lahar-hazard zone. The lahar-hazard zone in this study is based on the behavior of the Electron Mudflow, a lahar that traveled along the Puyallup River approximately 500 years ago and was due to a slope failure on the west flank of Mount Rainier. This lahar-hazard zone contains 78,049 residents, of which 11 percent are more than 65 years in age, 21 percent do not live in cities or unincorporated towns, and 39 percent of the households are renter occupied. The lahar-hazard zone contains 59,678 employees (4 percent of the four-county labor force) at 3,890 businesses that generate $16 billion in annual sales (4 and 7 percent, respectively, of totals in the four-county area) and tax parcels with a combined total value of $8.8 billion (2 percent of the study-area total). Employees in the lahar-hazard zone are primarily in businesses related to manufacturing, retail trade, transportation and warehousing, wholesale trade, and construction. Key road and rail corridors for the region are in the lahar-hazard zone, which could result in significant indirect economic losses for businesses that rely on these networks, such as the Port of Tacoma. Although occupancy values are not known for each site, the lahar-hazard zone contains numerous

  9. Anaphylaxis Due to Head Injury

    Directory of Open Access Journals (Sweden)

    Bruner, Heather C.

    2015-05-01

    Full Text Available Both anaphylaxis and head injury are often seen in the emergency department, but they are rarely seen in combination. We present a case of a 30-year-old woman who presented with anaphylaxis with urticaria and angioedema following a minor head injury. The patient responded well to intramuscular epinephrine without further complications or airway compromise. Prior case reports have reported angioedema from hereditary angioedema during dental procedures and maxillofacial surgery, but there have not been any cases of first-time angioedema or anaphylaxis due to head injury. [West J Emerg Med. 2015;16(3:435–437.

  10. Anaphylaxis due to head injury.

    Science.gov (United States)

    Bruner, Heather C; Bruner, David I

    2015-05-01

    Both anaphylaxis and head injury are often seen in the emergency department, but they are rarely seen in combination. We present a case of a 30-year-old woman who presented with anaphylaxis with urticaria and angioedema following a minor head injury. The patient responded well to intramuscular epinephrine without further complications or airway compromise. Prior case reports have reported angioedema from hereditary angioedema during dental procedures and maxillofacial surgery, but there have not been any cases of first-time angioedema or anaphylaxis due to head injury.

  11. Boxing-related head injuries.

    Science.gov (United States)

    Jayarao, Mayur; Chin, Lawrence S; Cantu, Robert C

    2010-10-01

    Fatalities in boxing are most often due to traumatic brain injury that occurs in the ring. In the past 30 years, significant improvements in ringside and medical equipment, safety, and regulations have resulted in a dramatic reduction in the fatality rate. Nonetheless, the rate of boxing-related head injuries, particularly concussions, remains unknown, due in large part to its variability in clinical presentation. Furthermore, the significance of repeat concussions sustained when boxing is just now being understood. In this article, we identify the clinical manifestations, pathophysiology, and management of boxing-related head injuries, and discuss preventive strategies to reduce head injuries sustained by boxers.

  12. Head-positioning scintillation camera and head holder therefor

    International Nuclear Information System (INIS)

    Kay, T.D.

    1976-01-01

    A holder for immobilizing the head of a patient undergoing a vertex brain scan by a Gamma Scintillation Camera is described. The holder has a uniquely designed shape capable of comfortably supporting the head. In addition, this holder can be both adjustably and removably utilized in combination with the scintillation camera so as to enable the brain scan operation to take place while the patient is in the seated position

  13. Head and Neck Cancer

    International Nuclear Information System (INIS)

    Tomita, Toshiki; Imanishi, Yorihisa

    2008-01-01

    The limitation of concurrent chemo-radiotherapy (CCRT) in head and neck cancer (HNC) as the primary treatment is described based on recent findings. Limits in the application/indication involve factors of age, performance status (PS) and renal function. The first is that, as deaths in >71 years old patients are derived from other causes (41%) than HNC, CCRT is only useful for younger population; the second, patients with PS 0-1 or Karnofsky performance score >60-70 can be indicated; and third, contraindicated are those with creatinine clearance (CCr) <60 mL/min as the key drug cisplatin in CCRT has a high renal toxicity. It should be recognized that completion rates of chemotherapy and RT are as low as 66-85% and 84-92%, respectively, in CCRT. CCRT has such limiting adverse events as mucitis, dry mouth, dysohagia, weight loss, neutropenia, sepsis, etc., which are most important in CCRT application. CCRT is recommended for the primary cancers of larynx and hypopharynx because they are significantly better conserved than middle pharyngeal, oral and upper jaw cancers. Evidence of CCRT is poor for cancers in paranasal sinuses. Planned neck dissection (PND) is for the cervical metastatic lymph nodes and conducted 6-12 weeks after CCRT regardless to its outcome. In fluorodeoxyglucose-positron emission tomography (FDG-PET) negative cases, PND can be omitted. Necessity of PND is possibly inversely proportional to CCRT intensity performed. For control of remote metastasis, CCRT has obvious limits and inductive chemotherapy before it is currently considered. Salvage surgery post CCRT does not always yield a relief because of complication. Patients with advanced laryngeal cancer can be selected either to surgery or CCRT depending on results of the inductive chemotherapy. To predict the sensitivity to CCRT, some biomarkers like HPV, EGFR and VEGF have been suggested to be useful by retrospective studies. Understanding the limitation is as important as knowing the usefulness in

  14. Receptor localization of steroid hormones and drugs: discoveries through the use of thaw-mount and dry-mount autoradiography

    Directory of Open Access Journals (Sweden)

    Stumpf W.E.

    1998-01-01

    Full Text Available The history of receptor autoradiography, its development and applications, testify to the utility of this histochemical technique for localizing radiolabeled hormones and drugs at cellular and subcellular sites of action in intact tissues. Localization of diffusible compounds has been a challenge that was met through the introduction of the "thaw-mount" and "dry-mount" autoradiographic techniques thirty years ago. With this cellular receptor autoradiography, used alone or combined with other histochemical techniques, sites of specific binding and deposition in vivo and in vitro have been characterized. Numerous discoveries, some reviewed in this article, provided information that led to new concepts and opened new areas of research. As an example, in recent years more than fifty target tissues for vitamin D have been specified, challenging the conventional view about the main biological role of vitamin D. The functions of most of these vitamin D target tissues are unrelated to the regulation of systemic calcium homeostasis, but pertain to the (seasonal regulation of endo- and exocrine secretion, cell proliferation, reproduction, neural, immune and cardiovascular responses, and adaptation to stress. Receptor autoradiography with cellular resolution has become an indispensable tool in drug research and development, since information can be obtained that is difficult or impossible to gain otherwise

  15. Sports-related Head Injury

    Science.gov (United States)

    ... and head gear come in many sizes and styles for many sports and must properly fit to ... to play or practice." The "Concussion Diagnosis and Management" section details circumstances in which an athlete should ...

  16. Heater head for stirling engine

    Science.gov (United States)

    Corey, John A.

    1985-07-09

    A monolithic heater head assembly which augments cast fins with ceramic inserts which narrow the flow of combustion gas and obtains high thermal effectiveness with the assembly including an improved flange design which gives greater durability and reduced conduction loss.

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... it may cause some medical devices to malfunction. Most orthopedic implants pose no risk, but you should ... a digital cloud server. Currently, MRI is the most sensitive imaging test of the head (particularly the ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... and may add approximately 15 minutes to the total exam time. top of page What will I ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head (particularly the brain) in routine clinical practice. top of page What are some common uses ... gadolinium contrast material except when absolutely necessary for medical treatment. See the MRI Safety page for more ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  1. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... Oral Surgeries Facial Cosmetic Surgery Facial Injury / Trauma Surgery Obstructive Sleep Apnea (OSA) Oral, Head and Neck Pathology TMJ and Facial Pain Wisdom Teeth Management Procedures Anesthesia Anesthesia Oral and maxillofacial surgeons are ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org : Radiation Therapy for Brain Tumors Radiation Therapy for ... Imaging (MRI) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  3. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... It can also invite bacteria that lead to gum disease. Click here to find out more. Who We ... It can also invite bacteria that lead to gum disease. Click here to find out more. Oral, Head ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head (particularly the brain) in routine clinical practice. top of page What are some common uses ... may follow your regular daily routine and take food and medications as usual. Some MRI examinations may ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... practice. top of page What are some common uses of the procedure? MR imaging of the head ... gadolinium contrast, it may still be possible to use it after appropriate pre-medication. Patient consent will ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... or headphones during the exam. MRI scanners are air-conditioned and well-lit. Music may be played ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... practice. top of page What are some common uses of the procedure? MR imaging of the head ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  8. American Head and Neck Society

    Science.gov (United States)

    ... research and insights. Comments This field is for validation purposes and should be left unchanged. This iframe ... and Announcements Copyright ©2016 · American Head and Neck Society · Privacy and Return Policy Managed by BSC Management, ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... practice. top of page What are some common uses of the procedure? MR imaging of the head ... for immediate assistance. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) of the head uses a powerful magnetic field, radio waves and a computer to produce detailed ... there’s a possibility you are pregnant. The magnetic field is not harmful, but it may cause some ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... by the interpreting radiologist. Frequently, the differentiation of abnormal (diseased) tissue from normal tissues is better with ... Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... medically necessary. MRI may not always distinguish between cancer tissue and fluid, known as edema . MRI typically ... Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association top ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a computer to produce detailed pictures of the brain and other cranial structures that are clearer and ... sensitive imaging test of the head (particularly the brain) in routine clinical practice. top of page What ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... practice. top of page What are some common uses of the procedure? MR imaging of the head ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... page Additional Information and Resources RTAnswers.org : Radiation Therapy for Brain Tumors Radiation Therapy for Head and ...

  16. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... teeth or become infected. It can also invite bacteria that lead to gum disease. Click here to find out ... and surgically treating cancer of the head, neck and mouth. The Oral Cancer Foundation estimates that close to ...

  17. Eye-based head gestures

    DEFF Research Database (Denmark)

    Mardanbegi, Diako; Witzner Hansen, Dan; Pederson, Thomas

    2012-01-01

    A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...... mobile phone screens. The user study shows that the method detects a set of defined gestures reliably.......A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...

  18. Surficial Geology of Mount Rainier National Park, Washington

    Science.gov (United States)

    Crandell, Dwight Raymond

    1969-01-01

    Much of the ground surface around Mount Rainier volcano is directly underlain by loose geologic deposits that veneer the hard rock formations. Examples of these deposits are sand and gravel bars along the rivers, ridges of loose rock debris beside the glaciers, and sloping aprons of rock fragments beneath almost every cliff. Even though they are generally thin and inconspicuous when compared with the rock formations, these surficial deposits are clues to geologic events that have profoundly influenced the shape of the park's landscape. Thus, from the character and extent of glacial deposits one can judge the age and size of former glaciers that carved the cirques and deep canyons of the park; from the mudflows which streamed down nearly every valley one can infer the age and size of huge landslides of the past that helped determine Mount Rainier's present shape; and from the pumice deposits some of the volcano's recent eruptive activity can be reconstructed. The map (plate 1, in pocket) that accompanies this description of the surficial deposits of Mount Rainier National Park shows the location of the various geologic formations, and the explanation shows the formations arranged in order of their relative age, with the oldest at the bottom. The text describes the surficial deposits in sequence from older to younger. A discussion of the pumice deposits of the park, which were not mapped, is followed by a description of the formations shown on the geologic map. Inspection of the geologic map may lead the viewer to question why the surficial deposits are shown in more detail in a zone several miles wide around the base of the volcano than elsewhere. This is partly because the zone is largely near or above timberline, relatively accessible, and the surficial deposits there can be readily recognized, differentiated, and mapped. In contrast, access is more difficult in the heavily timbered parts of the park, and surficial deposits there are generally blanketed by a dense

  19. Full waveform ambient noise tomography of Mount Rainer

    Science.gov (United States)

    Flinders, A. F.; Shen, Y.

    2014-12-01

    Mount Rainier towers over the landscape of western Washington, ranking with Fuji-yama in Japan, Mt. Pinatubo in the Philippines, and Mt. Vesuvius in Italy, as one of the great stratovolcanoes of the world. Notwithstanding it's picturesque stature, Mt. Rainier is potentially the most devastating stratovolcano in North America, with more than 3.5 million people living beneath its shadow in the Seattle-Tacoma area. The primary hazard posed by the volcano is in the form of highly destructive volcanic debris flows (lahars). These lahars form when water and/or melted ice erode away and entrain preexisting volcanic sediment. At Mt. Rainier these flows are often initiated by sector collapse of the volcano's hydrothermally rotten flanks and compounded from Mt. Rainier's extensive snow and glacial ice coverage. It is therefore imperative to ascertain the extent of summit hydrothermal alteration within the volcano, and determine areas prone to collapse. Despite being one of the sixteen volcanoes globally designated by the International Association of Volcanology and Chemistry of the Earth's Interior as warranting detailed and focused study, Mt. Rainier remains enigmatic both in terms of shallow internal structure and the degree of summit hydrothermal alteration. We image this shallow internal structure and areas of possible summit alteration using ambient noise tomography. Our full waveform forward modeling includes high-resolution topography, allowing us to accurately account for the effects of topography on the propagation of short-period Rayleigh waves. Empirical Green's functions were extracted from 80 stations within 200 km of Mount Rainier and compared with synthetic greens functions over multiple frequency bands from 2-28 seconds. The preliminary model shows a broad (60 km wide) low shear-wave velocity anomaly in the mid-crust beneath the volcano. The mid-crust low-velocity body extends to the surface beneath the volcano summit in a narrow near-vertical conduit, the

  20. Topiramate Responsive Exploding Head Syndrome

    OpenAIRE

    Palikh, Gaurang M.; Vaughn, Bradley V.

    2010-01-01

    Exploding head syndrome is a rare phenomenon but can be a significant disruption to quality of life. We describe a 39-year-old female with symptoms of a loud bang and buzz at sleep onset for 3 years. EEG monitoring confirmed these events occurred in transition from stage 1 sleep. This patient reported improvement in intensity of events with topiramate medication. Based on these results, topiramate may be an alternative method to reduce the intensity of events in exploding head syndrome.