WorldWideScience

Sample records for ultra trace concentrations

  1. Temperature Programmed Desorption of Quench-condensed Krypton and Acetone in Air; Selective Concentration of Ultra-trace Gas Components.

    Science.gov (United States)

    Suzuki, Taku T; Sakaguchi, Isao

    2016-01-01

    Selective concentration of ultra-trace components in air-like gases has an important application in analyzing volatile organic compounds in the gas. In the present study, we examined quench-condensation of the sample gas on a ZnO substrate below 50 K followed by temperature programmed desorption (TPD) (low temperature TPD) as a selective gas concentration technique. We studied two specific gases in the normal air; krypton as an inert gas and acetone as a reactive gas. We evaluated the relationship between the operating condition of low temperature TPD and the lowest detection limit. In the case of krypton, we observed the selective concentration by exposing at 6 K followed by thermal desorption at about 60 K. On the other hand, no selectivity appeared for acetone although trace acetone was successfully concentrated. This is likely due to the solvent effect by a major component in the air, which is suggested to be water. We suggest that pre-condensation to remove the water component may improve the selectivity in the trace acetone analysis by low temperature TPD.

  2. Development and optimization of a nuclear method to determine the lead concentration as an ultra-trace element in ultra-pure water

    International Nuclear Information System (INIS)

    Amara, A.; Giovagnoli, A.; Barrandon, J.N.

    1994-01-01

    Here we intend to perfect a nuclear analytical technique for the determination of lead concentration as an ultra-trace element in ultra-pure water Inmost cases the analysis of an aqueous solution is made by non-nuclear methods, therefore methods which are sensitive to the chemical form of the element to be determined. To ovoid this problem we developed a nuclear technique using a cyclotron,which allows the determination of the lead concentration in any of its chemical forms. We studied the possibilities of several incident beams, like neutral particles and charged particles. Proton activation showed to be the most sensitive of all the irradiation procedures. Several points have though be studied and developed: - an irradiation cell for liquids irradiation under a strong proton current; - the bismuth chemical separation. This element has two radio-isotopes allowing the determination of lead;-optimize the experimental irradiation and measurements parameters in order to reach the lower detection limit. At last an intercomparison of several techniques has been made for different standards. It clearly showed that, contrary to atomic,potentiometric or mass spectrometry methods,only activation technique give accurate and reproducible results. (author).1 fig., 2 tabs., 4 refs

  3. Present and Future Challenges in Trace and Ultra-Trace Analysis

    International Nuclear Information System (INIS)

    Toulhoat, P.

    2005-01-01

    The analysis of trace and ultra-trace elements is continuously stimulating the progress in analytical chemistry. Environmental chemistry, radiochemistry, biology, health, agri-food are prescribers of trace analyses, with continuously increasing exigencies: lowering detection limits, lowering costs and analysis time, improving the quality of analytical information. Precise data about the chemical identity and chemical environment of analytes are now requested. Such pieces of information, beyond simple numerical data and confidence intervals, are necessary to understand studied systems, and to predict their evolution. From environmental contamination cases, one can envisage the various aspects of a problem, with for each of them its own exigencies and specificities in terms of analytical methods and approaches. The detection of traces and ultra-traces of actinides and fission products has been recently revisited and stimulates new technological developments (non proliferation issues, waste management). Data on their speciation in geological and biological media are essential for evaluating the safety of nuclear waste repositories. Various techniques are now used to determine speciation in liquid samples or on surfaces, with tremendous spatial resolutions or sensitivities. A new revolution in analytical chemistry is expected with the development of micro- or nano-analytical technologies. (author)

  4. Ultra-Trace Analysis of Krypton-85

    International Nuclear Information System (INIS)

    Daerr, H.; Kalinowski, M.; Kohler, M.; Sahling, P.

    2010-01-01

    To strengthen the efficiency and effectiveness of nuclear safeguards for detecting undeclared nuclear material and activities we propose to use the radioactive krypton isotope Krypton-85 as a tracer for clandestine plutonium production. The main idea is to detect inexplicable atmospheric Kr85 concentration using the novel technology atom trap trace analysis (ATTA) in order to detect an undeclared reprocessing facility. The Additional Protocol (INFCIRC/540, 1997) establishes the possibility to take environmental samples. Krypton-85 has a combination of unique features which makes it an ideal tracer for plutonium separation activities anywhere in the world. It is always generated along with plutonium and 99.9% remains within the fuel cladding. Due to its half-life of 10.76 years, significant amounts of krypton-85 still remain in the spent fuel even after long cooling times. Krypton is not removed from the atmosphere by any processes like chemical reactions or wash-out. Furthermore, there are no other relevant sources of krypton-85 besides of reprocessing. The novel technology of atom trap trace analysis (ATTA) has been demonstrated by the physics group at Argonne National Laboratory in 1999. This is an ultra-sensitive trace analysis technique able to detect single krypton atoms. We are setting up an ATTA apparatus in our laboratory, which is designed to fulfill all requirements to detect clandestine plutonium production. Our goal is to determine Krypton-85 concentration of one liter samples of atmospheric air with an analysis time of 3 hours. This sample volume reduction is a significant step, since one liter can be taken as a grab sample by sucking it directly into pre-evacuated bottles at atmospheric pressure. The small samples size and the short analysis time of ATTA will make it possible to use krypton-85 as a tracer for clandestine plutonium production with routine operation. (author)

  5. Scandium - problem of ultra-trace-element essentiality

    International Nuclear Information System (INIS)

    Kist, A.A.; Zkuk, L.I.; Danilova, E.A.; Makhmudov, E.A.

    2006-01-01

    manifestations of the dysfunction after addition of deficient element. This is very convincing criterion but hardly acceptable for ultra trace elements as follows from the model given in the present paper. It is very simple to prepare diet with decreased level for constitutional essential and some trace-elements according to this criterion. It is enough to reduce some constitutional elements uptake for 50% to observe the organism dysfunction. For such trace elements like Mn, Cu, Zn it is enough to reduce its intake 1.5 - 5 times to reach the same effect. For Sc the factor of removal for humans should be about 500-1000. It is clear that preparation of nutrition which removal of ultra-trace elements with a purification factor of hundreds and thousands is practically impossible and there is a necessity to elaborate additional criteria for ultra-trace elements. (author)

  6. Ultra-micro trace element contents in spices from Sri Lanka

    International Nuclear Information System (INIS)

    Chery, C.C.; Herremans, S.; Van Lierde, V.; Vanhaecke, F.; Jasekera, R.

    2008-01-01

    Spices were analyzed by ICP-MS for determination of the ultra-micro trace elements in the human adult, Bi, Cd, Co, Ni, Pd, Pt, Se, Sn, Te, Tl, to complement previous results obtained by INAA and by EDXRF. The spices, originating from Sri Lanka, were curry, chilli powder and turmeric powders, coriander, cinnamon, black pepper, fennel, rampeh and curry leaves, and cumin. The analytical procedure was validated by analyzing the certified reference materials NIST SRM 1572 Citrus Leaves and NIST SRM 1573 Tomato Leaves. The results indicate that spices may contribute well to the daily optimal uptake of nutrients of a human adult. The adequacy of spices as a reference material with certified ultra micro trace elements is suggested. (author)

  7. The chemistry of ultra-low concentrations

    International Nuclear Information System (INIS)

    Vertes, Attila; Kiss, Istvan

    1987-01-01

    Methods for the separation and enrichment of radionuclides in the ultra-low concentration range (coprecipitation, adsorption of radioactive substances on crystals) are disscussed in this chapter of the textbook. The properties and behaviour of ultra-dilute solutions, radiocolloids and the electrochemistry of ultra-dilute solution are also overviewed

  8. Determination of trace and ultra-trace elements in Dergaon meteorite by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Balaram, V.; Gnaneswara Rao, T.; Anjaiah, K.V.; Phukon, N.; Majumdar, A.C.

    2003-01-01

    In this paper, a detailed methodology for high precision measurement of several trace and ultra-trace elements including REE and PGE have been presented using effective sample preparation techniques and inductively coupled plasma mass spectrometry. Discussion is focussed on aspects, such as total dissolution and recovery of all elements, minimization of oxide and doubly-charged and other polyatomic ion interferences, calibration by matrix matching standards, accuracy and precision

  9. A highly selective molecularly imprinted electrochemiluminescence sensor for ultra-trace beryllium detection

    International Nuclear Information System (INIS)

    Li, Jianping; Ma, Fei; Wei, Xiaoping; Fu, Cong; Pan, Hongcheng

    2015-01-01

    Graphical abstract: A novel molecular imprinted electrochemiluminescence sensor was fabricated for ultra-trace Be 2+ detection with an extremely lower detection limit based on the luminol–H 2 O 2 ECL system. - Highlights: • A novel molecular imprinted electrochemiluminescence sensor was fabricated for ultra-trace Be 2+ detection. • Imprint cavities in the MIPs from elution the Be–PAR complex could provide more recognition sites for analytes. • ECL emission produced by the luminol–H 2 O 2 ECL system, which was applied to detect Be 2+ . • It gave an extremely lower detection limit (2.35 × 10 −11 mol L −1 ) than the reported methods. - Abstract: A new molecularly imprinted electrochemiluminescence (ECL) sensor was proposed for highly sensitive and selective determination of ultratrace Be 2+ determination. The complex of Be 2+ with 4-(2-pyridylazo)-resorcinol (PAR) was chosen as the template molecule for the molecularly imprinted polymer (MIP). In this assay, the complex molecule could be eluted from the MIP, and the cavities formed could then selectively recognize the complex molecules. The cavities formed could also work as the tunnel for the transfer of probe molecules to produce sound responsive signal. The determination was based on the intensity of the signal, which was proportional to the concentrations of the complex molecule in the sample solution, and the Be 2+ concentration could then be determined indirectly. The results showed that in the range of 7 × 10 −11 mol L −1 to 8.0 × 10 −9 mol L −1 , the ECL intensity had a linear relationship with the Be 2+ concentrations, with the limit of detection of 2.35 × 10 −11 mol L −1 . This method was successfully used to detect Be 2+ in real water samples

  10. Determination of ultra-trace aluminum in human albumin by cloud point extraction and graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Sun Mei; Wu Qianghua

    2010-01-01

    A cloud point extraction (CPE) method for the preconcentration of ultra-trace aluminum in human albumin prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS) had been developed in this paper. The CPE method was based on the complex of Al(III) with 1-(2-pyridylazo)-2-naphthol (PAN) and Triton X-114 was used as non-ionic surfactant. The main factors affecting cloud point extraction efficiency, such as pH of solution, concentration and kind of complexing agent, concentration of non-ionic surfactant, equilibration temperature and time, were investigated in detail. An enrichment factor of 34.8 was obtained for the preconcentration of Al(III) with 10 mL solution. Under the optimal conditions, the detection limit of Al(III) was 0.06 ng mL -1 . The relative standard deviation (n = 7) of sample was 3.6%, values of recovery of aluminum were changed from 92.3% to 94.7% for three samples. This method is simple, accurate, sensitive and can be applied to the determination of ultra-trace aluminum in human albumin.

  11. Determination of ultra-trace aluminum in human albumin by cloud point extraction and graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sun Mei, E-mail: sunmei@ustc.edu.cn [Hefei National Laboratory for Physical Sciences on Microscale, University of Science and Technology of China, No. 96, Jinzhai Road, Hefei 230026 (China); Wu Qianghua [Department of Polymer Science and Engineering, University of Science and Technology of China, Hefei 230026 (China)

    2010-04-15

    A cloud point extraction (CPE) method for the preconcentration of ultra-trace aluminum in human albumin prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS) had been developed in this paper. The CPE method was based on the complex of Al(III) with 1-(2-pyridylazo)-2-naphthol (PAN) and Triton X-114 was used as non-ionic surfactant. The main factors affecting cloud point extraction efficiency, such as pH of solution, concentration and kind of complexing agent, concentration of non-ionic surfactant, equilibration temperature and time, were investigated in detail. An enrichment factor of 34.8 was obtained for the preconcentration of Al(III) with 10 mL solution. Under the optimal conditions, the detection limit of Al(III) was 0.06 ng mL{sup -1}. The relative standard deviation (n = 7) of sample was 3.6%, values of recovery of aluminum were changed from 92.3% to 94.7% for three samples. This method is simple, accurate, sensitive and can be applied to the determination of ultra-trace aluminum in human albumin.

  12. Using MOF-74 for Hg2+ removal from ultra-low concentration aqueous solution

    International Nuclear Information System (INIS)

    Xiong, Yang Yang; Li, Jian Qiang; Gong, Le Le; Feng, Xue Feng; Meng, Li Na; Zhang, Le; Meng, Pan Pan; Luo, Ming Biao; Luo, Feng

    2017-01-01

    Mercury (Hg 2+ ) ions have very high toxicity and widely spread as environmental pollutants. At present, many efforts have been taken to remove the hazardous materials of mercury(II) by adsorption, and it is highly desirable to develop a novel adsorbent with high adsorptive capacities. However it is still a big challenge to remove the ultra-low-concentration mercury ions from water. In this paper, MOF-74-Zn is explored for such function, showing high removal rate of Hg(II) from water without any pretreatment, especially for the ultra-trace Hg(II) ions in the ppb magnitude with the removal rate reaching to 54.48%, 69.71%, 72.26% when the initial concentration of Hg(II) is 20ppb, 40ppb, 50ppb, respectively. - Graphical abstract: The absorption of mercury ions on MOF-74-Zn is due to somewhat weak interactions between MOF skeleton that is composed of carboxylate and hydroxy group and Hg2+ ions. - Highlights: • MOF-74-Zn shows high removal rate of Hg(II) from water without any pretreatment. • The MOF-74-Zn has a notable performance at ultra-low concentration of Hg(II). • MOF-74-Zn shows the potential for Hg(II) removal from industrial waste water.

  13. Determination of ultra-trace aluminum in human albumin by cloud point extraction and graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Sun, Mei; Wu, Qianghua

    2010-04-15

    A cloud point extraction (CPE) method for the preconcentration of ultra-trace aluminum in human albumin prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS) had been developed in this paper. The CPE method was based on the complex of Al(III) with 1-(2-pyridylazo)-2-naphthol (PAN) and Triton X-114 was used as non-ionic surfactant. The main factors affecting cloud point extraction efficiency, such as pH of solution, concentration and kind of complexing agent, concentration of non-ionic surfactant, equilibration temperature and time, were investigated in detail. An enrichment factor of 34.8 was obtained for the preconcentration of Al(III) with 10 mL solution. Under the optimal conditions, the detection limit of Al(III) was 0.06 ng mL(-1). The relative standard deviation (n=7) of sample was 3.6%, values of recovery of aluminum were changed from 92.3% to 94.7% for three samples. This method is simple, accurate, sensitive and can be applied to the determination of ultra-trace aluminum in human albumin. 2009 Elsevier B.V. All rights reserved.

  14. Using MOF-74 for Hg{sup 2+} removal from ultra-low concentration aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, Yang Yang; Li, Jian Qiang; Gong, Le Le; Feng, Xue Feng; Meng, Li Na; Zhang, Le; Meng, Pan Pan; Luo, Ming Biao; Luo, Feng, E-mail: ecitluofeng@163.com

    2017-02-15

    Mercury (Hg{sup 2+}) ions have very high toxicity and widely spread as environmental pollutants. At present, many efforts have been taken to remove the hazardous materials of mercury(II) by adsorption, and it is highly desirable to develop a novel adsorbent with high adsorptive capacities. However it is still a big challenge to remove the ultra-low-concentration mercury ions from water. In this paper, MOF-74-Zn is explored for such function, showing high removal rate of Hg(II) from water without any pretreatment, especially for the ultra-trace Hg(II) ions in the ppb magnitude with the removal rate reaching to 54.48%, 69.71%, 72.26% when the initial concentration of Hg(II) is 20ppb, 40ppb, 50ppb, respectively. - Graphical abstract: The absorption of mercury ions on MOF-74-Zn is due to somewhat weak interactions between MOF skeleton that is composed of carboxylate and hydroxy group and Hg2+ ions. - Highlights: • MOF-74-Zn shows high removal rate of Hg(II) from water without any pretreatment. • The MOF-74-Zn has a notable performance at ultra-low concentration of Hg(II). • MOF-74-Zn shows the potential for Hg(II) removal from industrial waste water.

  15. Ultra Low Concentration Adsorption Equilibria

    National Research Council Canada - National Science Library

    Mahle, John J; Buettner, Leonard C; LeVan, M. D; Schindler, Bryan J

    2006-01-01

    .... Specifically this work focuses on novel experimental and modeling methods to characterize and predict at ultra-low chemical vapor concentrations the protection afforded by adsorption-based vapor filtration systems...

  16. Evaluation of trace organic contaminants in ultra-pure water production processes by measuring total organic halogen formation potential

    International Nuclear Information System (INIS)

    Urano, Kohei; Iwase, Yoko

    1984-01-01

    A new procedure for the determination of organic substances in water with high accuracy and high sensitivity was proposed, in which a hypochlorite is added to water, and the resultant total amount of organic halogen compounds (TOX formation potential) was measured, and it was applied to the evaluation of trace organic contaminants in ultra-pure water production process. In this investigation, the TOX formation potential of the raw water which was to be used for the ultra-pure water production process, intermediately treated water and ultra-pure water was measured to clarify the behavior of organic substances in the ultra-pure water production process and to demonstrate the usefulness of this procedure to evaluate trace organic contaminants in water. The measurement of TOX formation potential requires no specific technical skill, and only a short time, and gives accurate results, therefore, it is expected that the water quality control in the ultra-pure water production process can be performed more exactly by applying this procedure. (Yoshitake, I.)

  17. Solid sampling graphite furnace atomic absorption spectrometry for the direct analysis of microextraction solvent bars used for metal ultra-trace pre-concentration

    Science.gov (United States)

    González-Álvarez, Rafael Jesús; Pinto, Juan J.; Bellido-Milla, Dolores; Moreno, Carlos

    2017-09-01

    The potential applicability of the continuum source solid sampling graphite furnace atomic absorption spectroscopy (CS SS-GF AAS) technique has been studied to carry out the direct analysis of microextraction solvent bars used for metal ultra-trace pre-concentration in natural waters. An optimisation of the temperature program was developed for this purpose. Preliminary chamber furnace studies were performed in order to understand the behaviour of the bars with the increasing temperature. Solvent bars were filled with an acceptor solution, impregnated with an organic extractant and placed into the chamber furnace to carry out several temperature programs. Results led to perform a correct optimisation of the drying and pyrolysis steps of the furnace temperature program, which was tested with silver once completed. Blank solvent bars as well as standards containing silver were measured, obtaining a calibration curve with a correlation coefficient of 0.991. The results exhibited good repeatability and reproducibility, with relative standard deviations below 10% in both cases, indicating a promising applicability of the CS SS-GF AAS technique to directly determine metallic species in microextraction solvent bars.

  18. Ultra flat ideal concentrators of high concentration

    Energy Technology Data Exchange (ETDEWEB)

    Chaves, Julio [IST, Physics Dept., Lisboa (Portugal); INETI-DER, Lisboa (Portugal); Collares-Pereira, Manuel [INETI-DER, Lisboa (Portugal)

    2000-07-01

    A new method for the design of nonimaging devices is presented. Its application to the design of ultra flat compact concentrators is analysed. These new concentrators are based on a combination of two stages: the first one is composed of a large number of small structures placed side by side and the second one is a very compact single device concentrating the radiation to the limit. These devices are ideal for 2D. These compact designs are much more compact than the traditional ones like lens-mirror combinations or parabolic primaries with nonimaging secondaries. Besides, they can be designed for any acceptance angle, while the traditional ones are limited to small acceptance angles. (Author)

  19. Chemical characteristics and trace element concentration of non ...

    African Journals Online (AJOL)

    The present study investigates the details on the aspects of Coal quality such as proximate, ultimate, calorific value and trace element concentration and its impact on human health. Trace elements are present in very low percentage in coal but their concentration increases manifold after coal combustion and utilization.

  20. Ultra-trace determination of plutonium in marine samples using multi-collector inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Lindahl, Patric; Keith-Roach, Miranda; Worsfold, Paul; Choi, Min-Seok; Shin, Hyung-Seon; Lee, Sang-Hoon

    2010-06-25

    Sources of plutonium isotopes to the marine environment are well defined, both spatially and temporally, which makes Pu a potential tracer for oceanic processes. This paper presents the selection, optimisation and validation of a sample preparation method for the ultra-trace determination of Pu isotopes ((240)Pu and (239)Pu) in marine samples by multi-collector (MC) ICP-MS. The method was optimised for the removal of the interference from (238)U and the chemical recovery of Pu. Comparison of various separation strategies using AG1-X8, TEVA, TRU, and UTEVA resins to determine Pu in marine calcium carbonate samples is reported. A combination of anion-exchange (AG1-X8) and extraction chromatography (UTEVA/TRU) was the most suitable, with a radiochemical Pu yield of 87+/-5% and a U decontamination factor of 1.2 x 10(4). Validation of the method was accomplished by determining Pu in various IAEA certified marine reference materials. The estimated MC-ICP-MS instrumental limit of detection for (239)Pu and (240)Pu was 0.02 fg mL(-1), with an absolute limit of quantification of 0.11 fg. The proposed method allows the determination of ultra-trace Pu, at femtogram levels, in small size marine samples (e.g., 0.6-2.0 g coral or 15-20 L seawater). Finally, the analytical method was applied to determining historical records of the Pu signature in coral samples from the tropical Northwest Pacific and (239+240)Pu concentrations and (240)Pu/(239)Pu atom ratios in seawater samples as part of the 2008 GEOTRACES intercalibration exercise. Copyright 2010 Elsevier B.V. All rights reserved.

  1. Ultra-trace determination of plutonium in marine samples using multi-collector inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lindahl, Patric, E-mail: patriclindahl@yahoo.com [Marine Environment Research Department, Korea Ocean Research and Development Institute, 1270 Sadong, Ansan 426-744 (Korea, Republic of); School of Geography, Earth and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL48AA (United Kingdom); Keith-Roach, Miranda; Worsfold, Paul [School of Geography, Earth and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL48AA (United Kingdom); Choi, Min-Seok; Shin, Hyung-Seon [Division of Earth and Environmental Science, Korea Basic Science Institute, 113 Gwahangno, Yusung-gu, Daejon 305-333 (Korea, Republic of); Lee, Sang-Hoon [Marine Geology and Geophysics Laboratory, Korea Ocean Research and Development Institute, 1270 Sadong, Ansan 426-744 (Korea, Republic of)

    2010-06-25

    Sources of plutonium isotopes to the marine environment are well defined, both spatially and temporally, which makes Pu a potential tracer for oceanic processes. This paper presents the selection, optimisation and validation of a sample preparation method for the ultra-trace determination of Pu isotopes ({sup 240}Pu and {sup 239}Pu) in marine samples by multi-collector (MC) ICP-MS. The method was optimised for the removal of the interference from {sup 238}U and the chemical recovery of Pu. Comparison of various separation strategies using AG1-X8, TEVA, TRU, and UTEVA resins to determine Pu in marine calcium carbonate samples is reported. A combination of anion-exchange (AG1-X8) and extraction chromatography (UTEVA/TRU) was the most suitable, with a radiochemical Pu yield of 87 {+-} 5% and a U decontamination factor of 1.2 x 10{sup 4}. Validation of the method was accomplished by determining Pu in various IAEA certified marine reference materials. The estimated MC-ICP-MS instrumental limit of detection for {sup 239}Pu and {sup 240}Pu was 0.02 fg mL{sup -1}, with an absolute limit of quantification of 0.11 fg. The proposed method allows the determination of ultra-trace Pu, at femtogram levels, in small size marine samples (e.g., 0.6-2.0 g coral or 15-20 L seawater). Finally, the analytical method was applied to determining historical records of the Pu signature in coral samples from the tropical Northwest Pacific and {sup 239+240}Pu concentrations and {sup 240}Pu/{sup 239}Pu atom ratios in seawater samples as part of the 2008 GEOTRACES intercalibration exercise.

  2. Ultra-trace determination of plutonium in marine samples using multi-collector inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Lindahl, Patric; Keith-Roach, Miranda; Worsfold, Paul; Choi, Min-Seok; Shin, Hyung-Seon; Lee, Sang-Hoon

    2010-01-01

    Sources of plutonium isotopes to the marine environment are well defined, both spatially and temporally, which makes Pu a potential tracer for oceanic processes. This paper presents the selection, optimisation and validation of a sample preparation method for the ultra-trace determination of Pu isotopes ( 240 Pu and 239 Pu) in marine samples by multi-collector (MC) ICP-MS. The method was optimised for the removal of the interference from 238 U and the chemical recovery of Pu. Comparison of various separation strategies using AG1-X8, TEVA, TRU, and UTEVA resins to determine Pu in marine calcium carbonate samples is reported. A combination of anion-exchange (AG1-X8) and extraction chromatography (UTEVA/TRU) was the most suitable, with a radiochemical Pu yield of 87 ± 5% and a U decontamination factor of 1.2 x 10 4 . Validation of the method was accomplished by determining Pu in various IAEA certified marine reference materials. The estimated MC-ICP-MS instrumental limit of detection for 239 Pu and 240 Pu was 0.02 fg mL -1 , with an absolute limit of quantification of 0.11 fg. The proposed method allows the determination of ultra-trace Pu, at femtogram levels, in small size marine samples (e.g., 0.6-2.0 g coral or 15-20 L seawater). Finally, the analytical method was applied to determining historical records of the Pu signature in coral samples from the tropical Northwest Pacific and 239+240 Pu concentrations and 240 Pu/ 239 Pu atom ratios in seawater samples as part of the 2008 GEOTRACES intercalibration exercise.

  3. Adaptive sensor-based ultra-high accuracy solar concentrator tracker

    Science.gov (United States)

    Brinkley, Jordyn; Hassanzadeh, Ali

    2017-09-01

    Conventional solar trackers use information of the sun's position, either by direct sensing or by GPS. Our method uses the shading of the receiver. This, coupled with nonimaging optics design allows us to achieve ultra-high concentration. Incorporating a sensor based shadow tracking method with a two stage concentration solar hybrid parabolic trough allows the system to maintain high concentration with acute accuracy.

  4. Reaching ultra low phosphorus concentrations by filtration techniques

    NARCIS (Netherlands)

    Scherrenberg, S.M.

    2011-01-01

    This research deals with tertiary treatment techniques used for the removal of phosphorus from wastewater treatment plant (WWTP) effluent. The main objective of this research is to obtain ultra low total phosphorus (<0.15 mg total phosphorus/L) concentrations by coagulation, flocculation and

  5. Validation of a field filtration technique for characterization of suspended particulate matter from freshwater. Part II. Minor, trace and ultra trace elements

    International Nuclear Information System (INIS)

    Odman, Fredrik; Ruth, Thomas; Rodushkin, Ilia; Ponter, Christer

    2006-01-01

    A field filtration method for the concentration and separation of suspended particulate matter (SPM) from freshwater systems and the subsequent determination of minor, trace and ultra trace elements (As, Ba, Be, Cd, Co, Cr, Cs, Cu, Ga, Hf, Mo, Nb, Ni, Pb, Rb, Sb, Sc, Sn, Sr, Ta, Th, Tl, U, V, W, Zn and Zr) is validated with respect to detection limits, precision and bias. The validation comprises the whole procedure including filtration, sample digestion and instrumental analysis. The method includes two digestion procedures (microwave acid digestion and alkali fusion) in combination with inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma quadrupole mass spectrometry (ICP-QMS). Total concentrations of these 27 trace and minor elements have been determined in suspended particulate matter (SPM) from lake and river water with low levels of suspended solids ( -1 DW), and a wide range of element concentrations. The precision of the method including filtration, digestion and instrumental determination ranges between 8% and 18% RSD for most elements on a dry weight basis. Higher recovery after acid digestion is found for some elements, probably because of volatilization or retention losses in the fusion procedure. Other elements show higher recovery after fusion, which is explained by more efficient decomposition of refractory mineral phases relative to the non-total acid digestion. Non-detectable concentrations of some elements are reported due to small differences between blank filter levels and the amounts of elements present on the filters after sampling. The method limits of detection range between 0.7 ng and 2.65 μg, as estimated from the blank filter samples. These detection limits are 10-550 times higher compared to the corresponding instrumental limits of detection. The accuracy and bias of the overall analytical procedure was assessed from replicate analysis of certified reference materials. A critical evaluation of

  6. Direct analysis of ultra-trace semiconductor gas by inductively coupled plasma mass spectrometry coupled with gas to particle conversion-gas exchange technique.

    Science.gov (United States)

    Ohata, Masaki; Sakurai, Hiromu; Nishiguchi, Kohei; Utani, Keisuke; Günther, Detlef

    2015-09-03

    An inductively coupled plasma mass spectrometry (ICPMS) coupled with gas to particle conversion-gas exchange technique was applied to the direct analysis of ultra-trace semiconductor gas in ambient air. The ultra-trace semiconductor gases such as arsine (AsH3) and phosphine (PH3) were converted to particles by reaction with ozone (O3) and ammonia (NH3) gases within a gas to particle conversion device (GPD). The converted particles were directly introduced and measured by ICPMS through a gas exchange device (GED), which could penetrate the particles as well as exchange to Ar from either non-reacted gases such as an air or remaining gases of O3 and NH3. The particle size distribution of converted particles was measured by scanning mobility particle sizer (SMPS) and the results supported the elucidation of particle agglomeration between the particle converted from semiconductor gas and the particle of ammonium nitrate (NH4NO3) which was produced as major particle in GPD. Stable time-resolved signals from AsH3 and PH3 in air were obtained by GPD-GED-ICPMS with continuous gas introduction; however, the slightly larger fluctuation, which could be due to the ionization fluctuation of particles in ICP, was observed compared to that of metal carbonyl gas in Ar introduced directly into ICPMS. The linear regression lines were obtained and the limits of detection (LODs) of 1.5 pL L(-1) and 2.4 nL L(-1) for AsH3 and PH3, respectively, were estimated. Since these LODs revealed sufficiently lower values than the measurement concentrations required from semiconductor industry such as 0.5 nL L(-1) and 30 nL L(-1) for AsH3 and PH3, respectively, the GPD-GED-ICPMS could be useful for direct and high sensitive analysis of ultra-trace semiconductor gas in air. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Considerations on ultra-trace analysis of phthalates in drinking water.

    Science.gov (United States)

    Serôdio, P; Nogueira, J M F

    2006-07-01

    Stir bar sorptive extraction with liquid desorption followed by large volume injection and capillary gas chromatography coupled to mass spectrometry (SBSE-LD/LVI-GC-MS), had been applied for the determination of ultra-traces of seven-phthalates (dimethyl phthalate, diethyl phthalate, di-n-butyl phthalate, butyl benzyl phthalate, bis(2-ethylhexyl) adipate, bis(2-ethylhexyl) phthalate and bis(1-octyl) phthalate) in drinking water samples, which are included in the priority lists set by several international regulatory organizations. Instrumental calibration under the selected-ion monitoring mode acquisition (LVI-GC-MS(SIM)), experimental parameters that could affect the SBSE-LD efficiency, as well as, the control of the contamination profile are fully discussed. Throughout systematic assays on 30 mL water samples spiked at the 0.40 microg/L level, it had been established that stir bars coated with 47 microL of polydimethylsiloxane, an equilibrium time of 60 min (1,000 rpm) and methanol as back extraction solvent, allowed the best analytical performance to monitor phthalates in water matrices. From the data obtained, good accuracy and a remarkable reproducibility (water partition coefficients (K(PDMS/W) approximately K(O/W)), with the exception of bis(2-ethylhexyl) adipate, bis(2-ethylhexyl) phthalate and bis(1-octyl) phthalate, for which lower yields were measured. Additionally, a remarkable linear dynamic range between 25 and 2,000 ng/L (r(2)>0.99) and low detection limits (3-40 ng/L) were also achieved for the seven-phthalates studied. The application of the present method to monitor phthalates in tap and bottled mineral water samples, allowed convenient selectivity and high sensitivity up to 1.0 microg/L level, using the standard addition methodology. The proposed method showed to be feasible and sensitive with a low sample volume requirement to monitor phthalates in drinking water matrices at the ultra-trace level, in compliance with international regulatory

  8. Concentration of trace elements in marine organisms

    International Nuclear Information System (INIS)

    Ishii, Takaaki; Suzuki, Hamaji; Iimura, Mitsue; Koyanagi, Taku

    1976-01-01

    Information on the quality and quantity of stable trace elements in marine environments is frequently required to analyze the radioecological behavior of radionuclides released from nuclear facilities into the sea. In the present work, special attention was concentrated in determination of stable Mn, Fe, Co, Zn, Rb and Cs in marine organisms to estimate the concentration factors for these elements and corresponding radionuclides. Marine organisms (fishes, marine invertebrates and seaweeds) were collected at the seashore of Ibaragi prefecture and provided for chemical analysis after dry-ashing and wet-ashing. Atomic absorption spectrophotometry and neutron activation analysis were applied to determine the concentration of elements. The concentration of stable elements in fish muscle was independent on species of the fishes though slightly higher trends were observed in ''Usumebaru'', Sebastes nivosus for Cs, ''Ishimochi'', Nibea mitsukurii for Zn and Fe compared with other species. The concentration of Co, Zn and Fe in muscle of marine invertebrates was one order of magnitude higher than fish muscles especially in shellfishes for Co. Seaweeds showed peculiar species specificity for the concentration of stable trace elements and remarkable differences was observed between the species even among the same genus. (auth.)

  9. Australis: AMS for ultra sensitive trace element and isotopic studies

    Energy Technology Data Exchange (ETDEWEB)

    Sie, S H; Suter, G F [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1994-12-31

    The accelerator mass spectrometer (AMS) at the CSIRO HIAF laboratory is being upgraded to enable in-situ measurements of ultratraces and isotopic-ratios in mineralogical applications. The upgraded system will include a microbeam Cs ion source which is designed to produce better than 50 micrometre diameter Cs beam to enable analyses of monomineralic grains. The Cs primary beam will be mass analysed in order to minimize contamination of the sample. The detection system will be upgraded to enable analyses of elements up to U, at 2 MV terminal voltage for charge states 4 and 5. The system will be known as AUSTRALIS: A.M.S. for Ultra Sensitive TRAce eLement and Isotopic Studies. An overview of the system and the anticipated applications in minerals exploration and mining research are presented. 4 refs., 1 fig.

  10. Australis: AMS for ultra sensitive trace element and isotopic studies

    International Nuclear Information System (INIS)

    Sie, S.H.; Suter, G.F.

    1993-01-01

    The accelerator mass spectrometer (AMS) at the CSIRO HIAF laboratory is being upgraded to enable in-situ measurements of ultratraces and isotopic-ratios in mineralogical applications. The upgraded system will include a microbeam Cs ion source which is designed to produce better than 50 micrometre diameter Cs beam to enable analyses of monomineralic grains. The Cs primary beam will be mass analysed in order to minimize contamination of the sample. The detection system will be upgraded to enable analyses of elements up to U, at 2 MV terminal voltage for charge states 4 and 5. The system will be known as AUSTRALIS: A.M.S. for Ultra Sensitive TRAce eLement and Isotopic Studies. An overview of the system and the anticipated applications in minerals exploration and mining research are presented. 4 refs., 1 fig

  11. Australis: AMS for ultra sensitive trace element and isotopic studies

    Energy Technology Data Exchange (ETDEWEB)

    Sie, S.H.; Suter, G.F. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1993-12-31

    The accelerator mass spectrometer (AMS) at the CSIRO HIAF laboratory is being upgraded to enable in-situ measurements of ultratraces and isotopic-ratios in mineralogical applications. The upgraded system will include a microbeam Cs ion source which is designed to produce better than 50 micrometre diameter Cs beam to enable analyses of monomineralic grains. The Cs primary beam will be mass analysed in order to minimize contamination of the sample. The detection system will be upgraded to enable analyses of elements up to U, at 2 MV terminal voltage for charge states 4 and 5. The system will be known as AUSTRALIS: A.M.S. for Ultra Sensitive TRAce eLement and Isotopic Studies. An overview of the system and the anticipated applications in minerals exploration and mining research are presented. 4 refs., 1 fig.

  12. Establishment of ultra trace nuclear material analysis system

    International Nuclear Information System (INIS)

    Song, Kyuseok; Jee, Kwangyong; Lee, Changheon

    2012-05-01

    Highly accurate and precise analysis of ultra trace nuclear materials contained in swipe samples and environmental samples is required to improve the national nuclear transparency and the international nuclear security. The objectives of the first stage of this project are to develop the techniques for bulk analysis of environmental samples and the elemental techniques for particle analysis using FT-TIMS. To accomplish the objectives, state-of-the-art analytical instruments were set up followed by the development of the techniques for screening of nuclear materials, chemical treatement, particle handling, isotopic measurements using TIMS and ICP-MS, and fabrication of uranium microparticles. The verifications of the developed techniques were carried out by measurement of reference materials, and by participation to interlaboratory comparison programs. In additon, the establishement of a quality management system and the performance of the analysis of QC samples for IAEA-NWAL qualification were carried out to obtain the international accreditation for the related analytical system. In this report, the results of research and developments, and the achievements to obtain the international accreditation were summarized

  13. Log-stable concentration distributions of trace elements in biomedical samples

    International Nuclear Information System (INIS)

    Kubala-Kukus, A.; Kuternoga, E.; Braziewicz, J.; Pajek, M.

    2004-01-01

    In the present paper, which follows our earlier observation that the asymmetric and long-tailed concentration distributions of trace elements in biomedical samples, measured by the X-ray fluorescence techniques, can be modeled by the log-stable distributions, further specific aspects of this observation are discussed. First, we demonstrate that, typically, for a quite substantial fraction (10-20%) of trace elements studied in different kinds of biomedical samples, the measured concentration distributions are described in fact by the 'symmetric' log-stable distributions, i.e. the asymmetric distributions which are described by the symmetric stable distributions. This observation is, in fact, expected for the random multiplicative process, which models the concentration distributions of trace elements in the biomedical samples. The log-stable nature of concentration distribution of trace elements results in several problems of statistical nature, which have to be addressed in XRF data analysis practice. Consequently, in the present paper, the following problems, namely (i) the estimation of parameters for stable distributions and (ii) the testing of the log-stable nature of the concentration distribution by using the Anderson-Darling (A 2 ) test, especially for symmetric stable distributions, are discussed in detail. In particular, the maximum likelihood estimation and Monte Carlo simulation techniques were used, respectively, for estimation of stable distribution parameters and calculation of the critical values for the Anderson-Darling test. The discussed ideas are exemplified by the results of the study of trace element concentration distributions in selected biomedical samples, which were obtained by using the X-ray fluorescence (XRF, TXRF) methods

  14. Analyzing nitrogen concentration using carrier illumination (CI) technology for DPN ultra-thin gate oxide

    International Nuclear Information System (INIS)

    Li, W.S.; Wu, Bill; Fan, Aki; Kuo, C.W.; Segovia, M.; Kek, H.A.

    2005-01-01

    Nitrogen concentration in the gate oxide plays a key role for 90 nm and below ULSI technology. Techniques like secondary ionization mass spectroscopy (SIMS) and X-ray photoelectron spectroscopy (XPS) are commonly used for understanding N concentration. This paper describes the application of the carrier illuminationTM (CI) technique to measure the nitrogen concentration in ultra-thin gate oxides. A set of ultra-thin gate oxide wafers with different DPN (decoupled plasma nitridation) treatment conditions were measured using the CI technique. The CI signal has excellent correlation with the N concentration as measured by XPS

  15. Concentration distribution of trace elements: from normal distribution to Levy flights

    International Nuclear Information System (INIS)

    Kubala-Kukus, A.; Banas, D.; Braziewicz, J.; Majewska, U.; Pajek, M.

    2003-01-01

    The paper discusses a nature of concentration distributions of trace elements in biomedical samples, which were measured by using the X-ray fluorescence techniques (XRF, TXRF). Our earlier observation, that the lognormal distribution well describes the measured concentration distribution is explained here on a more general ground. Particularly, the role of random multiplicative process, which models the concentration distributions of trace elements in biomedical samples, is discussed in detail. It is demonstrated that the lognormal distribution, appearing when the multiplicative process is driven by normal distribution, can be generalized to the so-called log-stable distribution. Such distribution describes the random multiplicative process, which is driven, instead of normal distribution, by more general stable distribution, being known as the Levy flights. The presented ideas are exemplified by the results of the study of trace element concentration distributions in selected biomedical samples, obtained by using the conventional (XRF) and (TXRF) X-ray fluorescence methods. Particularly, the first observation of log-stable concentration distribution of trace elements is reported and discussed here in detail

  16. Major to ultra trace elements in rainfall collected in suburban Tokyo

    Science.gov (United States)

    Shimamura, Tadashi; Iwashita, Masato; Iijima, Satoe; Shintani, Megumi; Takaku, Yuichi

    Major to ultra trace elements such as rare earth elements (REEs), platinum group elements (PGEs) in 20 rainfall events from suburban Tokyo were determined by inductively coupled plasma mass spectrometry (ICP-MS). Anion species were also determined by an ion chromatography (IC). The concentrations of PGEs were so low that only Pt was detected in some rainfall events. Enrichment factors (EFs), refer to soil and sea salt components, were calculated for the measured elements (with Al and Na as references). Be, (Na), Mg, (Al), Si, Cl, K, Fe, Rb, Sr, REEs (except La, Gd), Ta, and U were mostly originated from natural materials (soil and sea salt). For Li, B, Ca, Mn, Sr, Ba, and Cs, the contribution of natural materials was significant. EFs for Cu, Zn, As, Se, Sb, Cd, Pb, Bi, Ag, Te, Au, Pt, SO 4-S and NO 3-N exceeded 100 indicating non-crustal, non-sea salt origin, presumably anthropogenic; however, contribution of volcanic gases could not be excluded for As, Se, Te and Bi. Pt seemed to be uniformly distributed worldwide and a catalyst for automobile emission control may be the main source. Au also showed uniform distribution. On the other hand, EFs for Zr, Nb, Hf and Th were less than unity. Probably these elements resided in acid resistant refractory fine minerals that did not decompose with acid treatment, and did not evaporate and ionize in the ICP. An alternative explanation is that the concentration of these elements was lower in the soil of the sampling area than the average crust. In the crust normalized REE pattern plot, La, Eu and Gd showed clear positive anomalies. La and Gd could have anthropogenic components. A possible source of La and Gd is cracking catalyst for petrol refining, but this source does not fully explain the anomaly. The source of Gd may also be Gd-DTPA (Gadolinium (III) diethyltriaminepentaacetic acid) used for Magnetic Resonance Imaging (MRI) contrast agents. The Eu origin may be soil with higher concentration than the crust average.

  17. Trace element concentrations in higher fungi

    International Nuclear Information System (INIS)

    Byrne, A.R.; Ravnik, V.; Kosta, L.

    1976-01-01

    The concentrations of ten trace elements, As, Br, Cd, Cu, Hg, I, Mn, Se, Zn and V, have been determined in up to 27 species of higher fungi from several sites in Slovenia, Yugoslavia. Analyses were based on destructive neutron activation techniques. Data are presented and compared with the concentrations found in soils. Previously values were non-existent or scanty for these elements, so that the data represent typical levels for basidiomycetes. In addition to confirming high levels of mercury in many species, the survey also found that cadmium is accumulated to a surprising extent by most fungi, the average value being 5 ppm. Among other accumulations found was bromine by the genus Amanita, and selenium by edible Boletus. Correlation analysis between all pairs of trace elements gave values for r of from 0.75 to 0.43 for 7 pairs (Cu and Hg, 0.75; Se and As, 0.69). As well as these features of biochemical interest, the values found and the pattern of accumulation suggest potential uses of fungi in environmental studies

  18. Highly selective micro-sequential injection lab-on-valve (muSI-LOV) method for the determination of ultra-trace concentrations of nickel in saline matrices using detection by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Long, Xiangbao; Miró, Manuel; Jensen, Rikard; Hansen, Elo Harald

    2006-10-01

    A highly selective procedure is proposed for the determination of ultra-trace level concentrations of nickel in saline aqueous matrices exploiting a micro-sequential injection Lab-On-Valve (muSI-LOV) sample pretreatment protocol comprising bead injection separation/pre-concentration and detection by electrothermal atomic absorption spectrometry (ETAAS). Based on the dimethylglyoxime (DMG) reaction used for nickel analysis, the sample, as contained in a pH 9.0 buffer, is, after on-line merging with the chelating reagent, transported to a reaction coil attached to one of the external ports of the LOV to assure sufficient reaction time for the formation of Ni(DMG)(2) chelate. The non-ionic coordination compound is then collected in a renewable micro-column packed with a reversed-phase copolymeric sorbent [namely, poly(divinylbenzene-co-N-vinylpyrrolidone)] containing a balanced ratio of hydrophilic and lipophilic monomers. Following elution by a 50-muL methanol plug in an air-segmented modality, the nickel is finally quantified by ETAAS. Under the optimized conditions and for a sample volume of 1.8 mL, a retention efficiency of 70 % and an enrichment factor of 25 were obtained. The proposed methodology showed a high tolerance to the commonly encountered alkaline earth matrix elements in environmental waters, that is, calcium and magnesium, and was successfully applied for the determination of nickel in an NIST standard reference material (NIST 1640-Trace elements in natural water), household tap water of high hardness and local seawater. Satisfying recoveries were achieved for all spiked environmental water samples with maximum deviations of 6 %. The experimental results for the standard reference material were not statistically different to the certified value at a significance level of 0.05.

  19. Concentration of trace elements on branded cigarette in Malaysia

    International Nuclear Information System (INIS)

    Azman, Muhammad Azfar; Hamzah, Suhaimi; Rahman, Shamsiah Abdul; Elias, Md Suhaimi; Abdullah, Nazaratul Ashifa; Hashim, Azian; Shukor, Shakirah Abd; Yasir, Muhamad Samudi; Rahman, Irman Abdul

    2016-01-01

    Tobacco is a plant that is used as a recreational drug since the beginning of its use by the Native Americans. Now with the development of the tobacco industry, smoking has become a norm for the public in Malaysia. Trace elements in plants are mostly due to the uptake processes from the soils into the roots of the plants. The concentration of the elements may also be influenced by the elements contained in the water and also fertilizers. This paper aim to analyze the concentration of the trace elements contained in the branded cigarettes sold in Malaysia by utilizing the neutron activation analysis. The tobaccos were taken out from the cigarettes. The collected samples were air dried and passed through 2 mm sieve. Instrumental Neutron Activation Analysis (NAA) has been used for the determination of trace elements. Samples were activated in the Nuclear Malaysia Triga Mark II reactor with a neutron flux of 2.0 x 10 12 n cm -2 s -1 . The samples then were analyzed using ORTEC Gamma Spectrometer a co-axial n-type HPGe detector with resolution of 2.0 keV at 1332 keV and relative efficiency of 20%. The data obtained could help in assessing the concentration of the trace elements that complying with the standard limitation dose proposed by World Health Organization (WHO)

  20. Concentration of trace elements on branded cigarette in Malaysia

    Science.gov (United States)

    Azman, Muhammad Azfar; Yasir, Muhamad Samudi; Rahman, Irman Abdul; Hamzah, Suhaimi; Rahman, Shamsiah Abdul; Elias, Md Suhaimi; Abdullah, Nazaratul Ashifa; Hashim, Azian; Shukor, Shakirah Abd

    2016-01-01

    Tobacco is a plant that is used as a recreational drug since the beginning of its use by the Native Americans. Now with the development of the tobacco industry, smoking has become a norm for the public in Malaysia. Trace elements in plants are mostly due to the uptake processes from the soils into the roots of the plants. The concentration of the elements may also be influenced by the elements contained in the water and also fertilizers. This paper aim to analyze the concentration of the trace elements contained in the branded cigarettes sold in Malaysia by utilizing the neutron activation analysis. The tobaccos were taken out from the cigarettes. The collected samples were air dried and passed through 2 mm sieve. Instrumental Neutron Activation Analysis (NAA) has been used for the determination of trace elements. Samples were activated in the Nuclear Malaysia Triga Mark II reactor with a neutron flux of 2.0 x 1012 n cm-2 s-1. The samples then were analyzed using ORTEC Gamma Spectrometer a co-axial n-type HPGe detector with resolution of 2.0 keV at 1332 keV and relative efficiency of 20%. The data obtained could help in assessing the concentration of the trace elements that complying with the standard limitation dose proposed by World Health Organization (WHO).

  1. Concentration of trace elements on branded cigarette in Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Azman, Muhammad Azfar, E-mail: m-azfar@nuclearmalaysia.gov.my; Hamzah, Suhaimi; Rahman, Shamsiah Abdul; Elias, Md Suhaimi; Abdullah, Nazaratul Ashifa; Hashim, Azian; Shukor, Shakirah Abd [Blok 18, Makmal Kimia Analisis (ACA/BAS), Agensi Nuklear Malaysia, 43000 Kajang, Selangor (Malaysia); Yasir, Muhamad Samudi; Rahman, Irman Abdul [Bangunan Sains Nuklear, Fakulti Sains & Teknologi, UKM Bangi, 43600 Bangi, Selangor (Malaysia)

    2016-01-22

    Tobacco is a plant that is used as a recreational drug since the beginning of its use by the Native Americans. Now with the development of the tobacco industry, smoking has become a norm for the public in Malaysia. Trace elements in plants are mostly due to the uptake processes from the soils into the roots of the plants. The concentration of the elements may also be influenced by the elements contained in the water and also fertilizers. This paper aim to analyze the concentration of the trace elements contained in the branded cigarettes sold in Malaysia by utilizing the neutron activation analysis. The tobaccos were taken out from the cigarettes. The collected samples were air dried and passed through 2 mm sieve. Instrumental Neutron Activation Analysis (NAA) has been used for the determination of trace elements. Samples were activated in the Nuclear Malaysia Triga Mark II reactor with a neutron flux of 2.0 x 10{sup 12} n cm{sup -2} s{sup -1}. The samples then were analyzed using ORTEC Gamma Spectrometer a co-axial n-type HPGe detector with resolution of 2.0 keV at 1332 keV and relative efficiency of 20%. The data obtained could help in assessing the concentration of the trace elements that complying with the standard limitation dose proposed by World Health Organization (WHO)

  2. Radionuclides and selected trace elements in marine protein concentrates

    Energy Technology Data Exchange (ETDEWEB)

    Beasley, T M; Jokela, T A; Eagle, R J

    1971-12-01

    The concentrations of various trace elements and radionuclides have been measured in marine protein concentrates prepared from surface feeding fishes. As with concentrates prepared from benthic fishes, the /sup 210/Pb-/sup 210/Po pair are the most significant radionuclides present. Concentrations of stable Pb, Co and Ag in certain concentrates are sufficiently high to contribute substantially to estimated current intakes of these elements.

  3. Atmospheric trace metal concentrations in Suspended Particulate ...

    African Journals Online (AJOL)

    The air particulate samples were collected from the kitchens, living rooms and outdoor environment of five households in the community. The quantification of the trace metals was done using Atomic Absorption spectrometry method, employing HNO based wet digestion. High baseline concentration of SPMwere obtained ...

  4. Magnetic matrix solid phase dispersion assisted dispersive liquid liquid microextraction of ultra trace polychlorinated biphenyls in water prior to GC-ECD determination

    International Nuclear Information System (INIS)

    Diao, Chunpeng; Li, Cong; Yang, Xiao; Sun, Ailing; Liu, Renmin

    2016-01-01

    Magnetic matrix solid phase dispersion (MMSPD) assisted dispersive liquid liquid microextraction (DLLME) was applied to extract ultra traces of polychlorinated biphenyls (PCBs) from water samples prior to gas chromatography with electron capture detection. PCBs in water were adsorbed by micro particles of magnetic bamboo charcoal and then transferred into the elution solvent. PCBs in the elution solvent of the MMSPD were further concentrated into trace volume extraction solvent of the DLLME procedure. Under optimized conditions, good linearity in the range of 0.2–100 ng L"−"1 was obtained with regression coefficients (r) higher than 0.9987. Based on a signal-noise ratio of 3, the limits of detection (LODs) range from 0.05–0.1 ng L"−"1. These LODs are much lower than those of MMSPD or DLLME alone. Relative standard deviations are between 4.9–8.2 %. The method was successfully applied to the determination of PCBs in lake and river water. Relative recoveries were 85.5–117.4 % for the spiked environmental water samples. (author)

  5. Serum Concentrations of Trace Elements in Patients with Tuberculosis and Its Association with Treatment Outcome

    Directory of Open Access Journals (Sweden)

    Rihwa Choi

    2015-07-01

    Full Text Available Deficiencies in essential trace elements are associated with impaired immunity in tuberculosis infection. However, the trace element concentrations in the serum of Korean patients with tuberculosis have not yet been investigated. This study aimed to compare the serum trace element concentrations of Korean adult patients with tuberculosis with noninfected controls and to assess the impact of serum trace element concentration on clinical outcome after antituberculosis treatment. The serum concentrations of four trace elements in 141 consecutively recruited patients with tuberculosis and 79 controls were analyzed by inductively coupled plasma-mass spectrometry. Demographic characteristics were also analyzed. Serum cobalt and copper concentrations were significantly higher in patients with tuberculosis compared with controls, while zinc and selenium concentrations were significantly lower (p < 0.01. Moreover, serum selenium and zinc concentrations were positively correlated (ρ = 0.41, p < 0.05. A high serum copper concentration was associated with a worse clinical outcome, as assessed after one month of antituberculosis therapy. Specifically, culture-positive patients had higher serum copper concentrations than culture-negative patients (p < 0.05. Patients with tuberculosis had altered serum trace element concentrations. Further research is needed to elucidate the roles of individual trace elements and to determine their clinical impact on patients with tuberculosis.

  6. Trace metal concentrations in tropical mangrove sediments, NE Brazil.

    Science.gov (United States)

    Miola, Brígida; Morais, Jáder Onofre de; Pinheiro, Lidriana de Souza

    2016-01-15

    Sediment cores were taken from the mangroves of the Coreaú River estuary off the northeast coast of Brazil. They were analyzed for grain size, CaCO3, organic matter, and trace metal (Cd, Pb, Zn, Cu, Al, and Fe) contents. Mud texture was the predominant texture. Levels of trace metals in surface sediments indicated strong influence of anthropogenic processes, and diagenetic processes controlled the trace metal enrichment of core sediments of this estuary. The positive relationships between trace metals and Al and Fe indicate that Cu, Zn, Pb, and Cd concentrations are associated mainly with Al and Fe oxy-hydroxides and have natural sources. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Trace and ultratrace level elemental and speciation analysis

    International Nuclear Information System (INIS)

    Arunachalam, J.

    2012-01-01

    Accurate determination of elements present at parts per million and billion levels in various matrices is a growing requirement in different fields. In environmental sciences various trace elements need to be analyzed so as establish the dispersal models of pollutants or the adequacy of effluent treatment prior to discharge into water bodies. The issues of bioaccumulation and magnification are important in aquatic systems. In nutrition and biochemistry one has to establish the bio-availability of essential and toxic elemental species as toxic elements prevent assimilation of essential elements. Fission and fusion technologies use a variety of structural materials requiring many trace elements to be present at levels strictly below the specified levels. Ultra-pure bulk semiconductor materials are required for fabrication devices. In metallurgy and materials sciences too, various trace elements are known to influence the properties. In the emerging fields like nanotechnology, it is necessary to understand the passage and accumulation of nano-particles inside the cells, through trace analysis. Many analytical techniques exist which can provide the concentration information in the bulk materials with good accuracy. They include ICP-AES, FAAS, and ICP-MS, which are solution based techniques. Direct solid state analytical techniques are Glow Discharge Mass Spectrometry (GDMS) and XRF. Accelerator based ion-beam analysis techniques can provide information on concentration and depth profiles of different elements in layered structures. Hyphenated techniques such as HPLC/lC-ICPMS, are helpful in identifying various chemical oxidation states in which a given element might be present in a matrix, which is termed as speciation analysis. This presentation will include the existing analytical competencies and the laboratory requirements for trace and ultra trace element elemental and speciation analyses and their applications. (author)

  8. Concentration of trace metals in boreholes in the Ankobra Basin, Ghana

    International Nuclear Information System (INIS)

    Kortasi, B. K.

    2006-01-01

    Analysis of trace metals in ground water from the Ankobra basin revealed high levels of iron, manganese and aluminium. Approximately 40% of boreholes had total iron concentration exceeding 1000 μ 1 -1 (maximum WHO permissible limit). Aluminium concentration varied from 0.1 μ to 2510 μ 1 -1 with a median value of 10.0 μ 1 -1 . Approximately 20% of the boreholes had aluminium concentration exceeding the WHO maximum acceptable limit (200 μ 1 -1 ) for drinking water. Manganese concentration was in the range 6-2510 μ 1 -1 with a median of 356 μ 1 -1 . Roughly 25% of the boreholes had manganese concentrations higher that 500 μ 1 -1 , which is the WHO maximum acceptable limit for drinking water. The concentrations of mercury was higher than 1.0 μ 1 -1 (WHO maximum acceptable limit) in 60% of the boreholes during the rainy season but below detection limit in the dry season, suggesting anthropogenic origin for mercury in the groundwater. Other trace metals that occurred, but in insignificant concentration in the boreholes, include lead, arsenic, nickel and selenium. Most of the boreholes with high trace metal concentrations were located in and around the Bawdie-Bogoso-Prestea area. (au)

  9. Reduced trace element concentrations in fast-growing juvenile Atlantic salmon in natural streams.

    Science.gov (United States)

    Ward, Darren M; Nislow, Keith H; Chen, Celia Y; Folt, Carol L

    2010-05-01

    To assess the effect of rapid individual growth on trace element concentrations in fish, we measured concentrations of seven trace elements (As, Cd, Cs, Hg, Pb, Se, Zn) in stream-dwelling Atlantic salmon (Salmo salar) from 15 sites encompassing a 10-fold range in salmon growth. All salmon were hatched under uniform conditions, released into streams, and sampled approximately 120 days later for trace element analysis. For most elements, element concentrations in salmon tracked those in their prey. Fast-growing salmon had lower concentrations of all elements than slow growers, after accounting for prey concentrations. This pattern held for essential and nonessential elements, as well as elements that accumulate from food and those that can accumulate from water. At the sites with the fastest salmon growth, trace element concentrations in salmon were 37% (Cs) to 86% (Pb) lower than at sites where growth was suppressed. Given that concentrations were generally below levels harmful to salmon and that the pattern was consistent across all elements, we suggest that dilution of elements in larger biomass led to lower concentrations in fast-growing fish. Streams that foster rapid, efficient fish growth may produce fish with lower concentrations of elements potentially toxic for human and wildlife consumers.

  10. Trends and applications of integrated automated ultra-trace sample handling and analysis (T9)

    International Nuclear Information System (INIS)

    Kingston, H.M.S.; Ye Han; Stewart, L.; Link, D.

    2002-01-01

    Full text: Automated analysis, sub-ppt detection limits, and the trend toward speciated analysis (rather than just elemental analysis) force the innovation of sophisticated and integrated sample preparation and analysis techniques. Traditionally, the ability to handle samples at ppt and sub-ppt levels has been limited to clean laboratories and special sample handling techniques and equipment. The world of sample handling has passed a threshold where older or 'old fashioned' traditional techniques no longer provide the ability to see the sample due to the influence of the analytical blank and the fragile nature of the analyte. When samples require decomposition, extraction, separation and manipulation, application of newer more sophisticated sample handling systems are emerging that enable ultra-trace analysis and species manipulation. In addition, new instrumentation has emerged which integrate sample preparation and analysis to enable on-line near real-time analysis. Examples of those newer sample-handling methods will be discussed and current examples provided as alternatives to traditional sample handling. Two new techniques applying ultra-trace microwave energy enhanced sample handling have been developed that permit sample separation and refinement while performing species manipulation during decomposition. A demonstration, that applies to semiconductor materials, will be presented. Next, a new approach to the old problem of sample evaporation without losses will be demonstrated that is capable of retaining all elements and species tested. Both of those methods require microwave energy manipulation in specialized systems and are not accessible through convection, conduction, or other traditional energy applications. A new automated integrated method for handling samples for ultra-trace analysis has been developed. An on-line near real-time measurement system will be described that enables many new automated sample handling and measurement capabilities. This

  11. Ultra-trace analysis of hormones, pharmaceutical substances, alkylphenols and phthalates in two French natural mineral waters

    Energy Technology Data Exchange (ETDEWEB)

    Dévier, Marie-Hélène; Le Menach, Karyn [Environnements et Paléoenvironnements Océaniques et Continentaux (EPOC, UMR 5805 CNRS), Laboratoire de Physico- et Toxico-Chimie de l' Environnement (LPTC), Université de Bordeaux, 351 cours de la Libération, 33405 Talence cedex (France); Viglino, Liza [Danone Waters Analytical Center, Aqualab, Place de la Gare, 74500 Evian-Les-Bains (France); Di Gioia, Lodovico [Danone Research, R and D Waters Division, RD 128, 91767 Palaiseau Cedex (France); Lachassagne, Patrick [Danone Waters France, Environment and Water Resources Division, BP 87, 11 av. Général Dupas, 74500 Evian-Les-Bains cedex (France); Budzinski, Hélène, E-mail: h.budzinski@epoc.u-bordeaux1.fr [Environnements et Paléoenvironnements Océaniques et Continentaux (EPOC, UMR 5805 CNRS), Laboratoire de Physico- et Toxico-Chimie de l' Environnement (LPTC), Université de Bordeaux, 351 cours de la Libération, 33405 Talence cedex (France)

    2013-01-15

    The aim of this work was to investigate the potential presence of a broad range of organic compounds, such as hormones, alkylphenols, bisphenol A and phthalates, as well as pharmaceutical substances in two brands of bottled natural mineral waters (Evian and Volvic, Danone). The phthalates were determined by solid-phase microextraction coupled to gas chromatography–mass spectrometry (SPME-GC–MS) and the other compounds by liquid chromatography–tandem mass spectrometry (LC–MS/MS) or gas chromatography–mass spectrometry (GC–MS) after solid-phase extraction. The potential migration of alkylphenols, bisphenol A and phthalates from polyethylene terephthalate (PET) bottles was also investigated under standardized test conditions. Evian and Volvic natural mineral waters contain none of the around 120 targeted organic compounds. Traces of 3 pharmaceuticals (ketoprofen, salicylic acid, and caffeine), 3 alkylphenols (4-nonylphenol, 4-t-octylphenol, and 4-nonylphenol diethoxylate), and some phthalates including di(2-ethylhexyl)phthalate (DEHP) were detected in the samples, but they were also present in the procedural blanks at similar levels. The additional test procedures demonstrated that the few detected compounds originated from the background laboratory contamination. Analytical procedures have been designed both in the bottling factory and in the laboratory in order to investigate the sources of DEHP and to minimize to the maximum this unavoidable laboratory contamination. It was evidenced that no migration of the targeted compounds from bottles occurred under the test conditions. The results obtained in this study underline the complexity of reaching a reliable measure to qualify the contamination of a sample at ultra-trace level, in the field of very pure matrices. The analytical procedures involving glassware, equipment, hoods, and rooms specifically dedicated to trace analysis allowed us to reach reliable procedural limits of quantification at the ng

  12. Ultra-trace analysis of hormones, pharmaceutical substances, alkylphenols and phthalates in two French natural mineral waters

    International Nuclear Information System (INIS)

    Dévier, Marie-Hélène; Le Menach, Karyn; Viglino, Liza; Di Gioia, Lodovico; Lachassagne, Patrick; Budzinski, Hélène

    2013-01-01

    The aim of this work was to investigate the potential presence of a broad range of organic compounds, such as hormones, alkylphenols, bisphenol A and phthalates, as well as pharmaceutical substances in two brands of bottled natural mineral waters (Evian and Volvic, Danone). The phthalates were determined by solid-phase microextraction coupled to gas chromatography–mass spectrometry (SPME-GC–MS) and the other compounds by liquid chromatography–tandem mass spectrometry (LC–MS/MS) or gas chromatography–mass spectrometry (GC–MS) after solid-phase extraction. The potential migration of alkylphenols, bisphenol A and phthalates from polyethylene terephthalate (PET) bottles was also investigated under standardized test conditions. Evian and Volvic natural mineral waters contain none of the around 120 targeted organic compounds. Traces of 3 pharmaceuticals (ketoprofen, salicylic acid, and caffeine), 3 alkylphenols (4-nonylphenol, 4-t-octylphenol, and 4-nonylphenol diethoxylate), and some phthalates including di(2-ethylhexyl)phthalate (DEHP) were detected in the samples, but they were also present in the procedural blanks at similar levels. The additional test procedures demonstrated that the few detected compounds originated from the background laboratory contamination. Analytical procedures have been designed both in the bottling factory and in the laboratory in order to investigate the sources of DEHP and to minimize to the maximum this unavoidable laboratory contamination. It was evidenced that no migration of the targeted compounds from bottles occurred under the test conditions. The results obtained in this study underline the complexity of reaching a reliable measure to qualify the contamination of a sample at ultra-trace level, in the field of very pure matrices. The analytical procedures involving glassware, equipment, hoods, and rooms specifically dedicated to trace analysis allowed us to reach reliable procedural limits of quantification at the ng

  13. Determination of Trace Concentration in TMD Detectors using PGAA

    Directory of Open Access Journals (Sweden)

    Tomandl I.

    2015-01-01

    Full Text Available Transmutation detectors could be alternative to the traditional activation detector method for neutron fluence dosimetry at power nuclear reactors. This new method require an isotopically highly-sensitive, non-destructive in sense of compactness as well as isotopic content, precise and standardly used analytical method for trace concentration determination. The capability of Prompt Gamma-ray Activation Analysis (PGAA for determination of trace concentrations of transmuted stable nuclides in the metallic foils of Ni, Au, Cu and Nb, which were irradiated for 21 days in the reactor core at the LVR-15 research reactor in Řež, is reported. The PGAA measurements of these activation foils were performed at the PGAA facility at Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRMII in Garching.

  14. Determination of ultra trace arsenic species in water samples by hydride generation atomic absorption spectrometry after cloud point extraction

    Energy Technology Data Exchange (ETDEWEB)

    Ulusoy, Halil Ibrahim, E-mail: hiulusoy@yahoo.com [University of Cumhuriyet, Faculty of Science, Department of Chemistry, TR-58140, Sivas (Turkey); Akcay, Mehmet; Ulusoy, Songuel; Guerkan, Ramazan [University of Cumhuriyet, Faculty of Science, Department of Chemistry, TR-58140, Sivas (Turkey)

    2011-10-10

    Graphical abstract: The possible complex formation mechanism for ultra-trace As determination. Highlights: {yields} CPE/HGAAS system for arsenic determination and speciation in real samples has been applied first time until now. {yields} The proposed method has the lowest detection limit when compared with those of similar CPE studies present in literature. {yields} The linear range of the method is highly wide and suitable for its application to real samples. - Abstract: Cloud point extraction (CPE) methodology has successfully been employed for the preconcentration of ultra-trace arsenic species in aqueous samples prior to hydride generation atomic absorption spectrometry (HGAAS). As(III) has formed an ion-pairing complex with Pyronine B in presence of sodium dodecyl sulfate (SDS) at pH 10.0 and extracted into the non-ionic surfactant, polyethylene glycol tert-octylphenyl ether (Triton X-114). After phase separation, the surfactant-rich phase was diluted with 2 mL of 1 M HCl and 0.5 mL of 3.0% (w/v) Antifoam A. Under the optimized conditions, a preconcentration factor of 60 and a detection limit of 0.008 {mu}g L{sup -1} with a correlation coefficient of 0.9918 was obtained with a calibration curve in the range of 0.03-4.00 {mu}g L{sup -1}. The proposed preconcentration procedure was successfully applied to the determination of As(III) ions in certified standard water samples (TMDA-53.3 and NIST 1643e, a low level fortified standard for trace elements) and some real samples including natural drinking water and tap water samples.

  15. Major and trace element geochemistry and background concentrations for soils in Connecticut

    Science.gov (United States)

    Brown, Craig; Thomas, Margaret A.

    2014-01-01

    Soil samples were collected throughout Connecticut (CT) to determine the relationship of soil chemistry with the underlying geology and to better understand background concentrations of major and trace elements in soils. Soil samples were collected (1) from the upper 5 cm of surficial soil at 100 sites, (2) from the A horizon at 86 of these sites, and (3) from the deeper horizon, typically the C horizon, at 79 of these sites. The Ca, Fe, K, Na, and Ti, but element concentrations showed a relatively similar pattern in A-horizon and surficial soil samples among the underlying geologic provinces. Trace element concentrations, including Ba, W, Ga, Ni, Cs, Rb, Sr, Th, Sc, and U, also were higher in C-horizon soil samples than in overlying soil samples. Concentrations of Mg, and several trace elements, including Mn, P, As, Nb, Sn, Be, Bi, Hg, Se, Sb, La, Co, Cr, Pb, V, Y, Cu, Pb, and Zn were highest in some A-horizon or surficial soils, and indicate possible contributions from anthropogenic sources. Because element concentrations in soils above the C horizon are more likely to be affected by anthropogenic factors, concentration ranges in C-horizon soils and their spatially varying geologic associations should be considered when estimating background concentrations of elements in CT soils.

  16. Accurate determination of ultra-trace levels of Ti in blood serum using ICP-MS/MS

    International Nuclear Information System (INIS)

    Balcaen, Lieve; Bolea-Fernandez, Eduardo; Resano, Martín; Vanhaecke, Frank

    2014-01-01

    Graphical abstract: -- Highlights: •Novel method for determination of Ti at ultra-trace levels in clinical samples (serum). •Novel method based on Ti(NH 3 ) 6 + reaction product ion formation and double mass selection using recently introduced ICP-QQQ instrumentation. •Lowest limits of detection ever obtained using quadrupole-based instrumentation for Ti. •Accurate determination of basal levels of Ti in blood serum. -- Abstract: Ti is frequently used in implants and prostheses and it has been shown before that the presence of these in the human body can lead to elevated Ti concentrations in body fluids such as serum and urine. As identification of the exact mechanisms responsible for this increase in Ti concentrations, and the risks associated with it, are not fully understood, it is important to have sound analytical methods that enable straightforward quantification of Ti levels in body fluids (for both implanted and non-implanted individuals). Until now, only double-focusing sector field ICP-mass spectrometry (SF-ICP-MS) offered limits of detection that are good enough to deal with the very low basal levels of Ti in human serum. This work reports on the development of a novel method for the accurate and precise determination of trace levels of Ti in human serum samples, based on the use of ICP-MS/MS. O 2 and NH 3 /He have been compared as reaction gases. While the use of O 2 did not enable to overcome all spectral interferences, it has been shown that conversion of Ti + ions into Ti(NH 3 ) 6 + cluster ions by using NH 3 /He as a reaction gas in an ICP-QQQ-MS system, operated in MS/MS mode, provided interference-free conditions and sufficiently low limits of detection, down to 3 ng L −1 (instrumental detection limit obtained for the most abundant Ti isotope). The accuracy of the method proposed was evaluated by analysis of a Seronorm Trace Elements Serum L-1 reference material and by comparing the results obtained with those achieved by means of SF

  17. Trace Elements Concentrations in Water and Aquatic Biota from Ase ...

    African Journals Online (AJOL)

    Trace Elements Concentrations in Water and Aquatic Biota from Ase Creek in Niger ... arsenic, chromium, lead, molybdenum, bismuth and cadmium using atomic ... metal pollution, metal variation, environmental monitoring, bioaccumulation.

  18. Flotation-separation and ICP-AES determination of ultra trace amounts of copper, cadmium, nickel and cobalt using 2-aminocyclopentene-1-dithiocarboxylic acid.

    Science.gov (United States)

    Shamsipur, Mojtaba; Hashemi, Omid Reza; Safavi, Afsaneh

    2005-09-01

    A rapid flotation method for separation and enrichment of ultra trace amounts of copper(II), cadmium(II), nickel(II) and cobalt(II) ions from water samples is established. At pH 6.5 and with sodium dodecylsulfate used as a foaming reagent, Cu2+, Cd2+, Ni2+ and Co2+ were separated simultaneously with 2-aminocyclopentene-1-dithiocarboxylic acid (ACDA) added to 1 l of aqueous solution. The proposed procedure of preconcentration is applied prior to the determination of these four analytes using inductivity coupled plasma-atomic emission spectrometry (ICP-AES). The effects of pH, concentration of ACDA, applicability of different surfactants and foreign ions on the separation efficiency were investigated. The preconcentration factor of the method is 1000 and the detection limits of copper(II), cadmium(II), nickel(II) and cobalt(II) ions are 0.078, 0.075, 0.072 and 0.080 ng ml(-1), respectively.

  19. Use and abuse of trace metal concentrations in plant tissue for biomonitoring and phytoextraction

    NARCIS (Netherlands)

    Mertens, Jan; Luyssaert, Sebastiaan; Verheyen, Kris

    2005-01-01

    Some plant species accumulate trace metals from the soil in their aboveground biomass. Therefore, some scientists have concluded that these species are suitable for biomonitoring trace metal concentrations in the soil or for removing excessive trace metals from the soil by means of phytoextraction.

  20. Use and abuse of trace metal concentrations in plant tissue for biomonitoring and phytoextraction

    International Nuclear Information System (INIS)

    Mertens, Jan; Luyssaert, Sebastiaan; Verheyen, Kris

    2005-01-01

    Some plant species accumulate trace metals from the soil in their aboveground biomass. Therefore, some scientists have concluded that these species are suitable for biomonitoring trace metal concentrations in the soil or for removing excessive trace metals from the soil by means of phytoextraction. A significant correlation between the chemical composition of foliage and soil is not a sufficient condition for using the chemical composition of foliage as a biomonitor for the quality of the soil. The chemical composition of foliage can, however, provide additional information to the traditional soil samples. The phytoextraction potential of a plant species cannot solely be evaluated on the basis of the trace metal concentrations in the plant and soil tissue. Data on the depth of the rooting zone, the density of the soil and the harvestable biomass should also be taken into account. Although plant tissue analysis is a useful tool in a wide range of studies and applications, trace metal concentrations in plant tissue cannot be viewed in isolation. Instead it should be analysed and interpreted in relation to other information such as soil concentrations, rooted zone, biomass production, etc. - Plants that accumulate soil metals in their aboveground biomass are often incorrectly considered to be suitable for monitoring soil pollution or for phytoextraction purposes

  1. State of the art in sample preparation for trace element analysis (M1)

    International Nuclear Information System (INIS)

    Barnes, R.M.

    2002-01-01

    Full text: The accelerated capabilities of modern trace element analysis techniques, especially inductively coupled plasma mass spectrometry (ICP-MS), have challenged the sample preparation competence of most laboratories. Exceptional analytical sensitivity, remarkable analysis speed, automated sample presentation, and intelligent sample sequencing of modern spectroscopic instrumentation have lead to demanding requirements for appropriate sample preparation steps needed for ultra trace concentration and speciation measurements. Contamination control, reliable digestion and extraction techniques, presentation of chemical forms, sample matrix management, and intelligent sample processing available today are often inadequate for the most demanding measurements. Some commercial instrumentation provides convenient implementation of well-established contamination control measures, and reagent and container purity are steadily being improved. Direct sample introduction approaches offer alternatives to conventional solution samples, but achieving calibration reliability is difficult. Developing new sample preparation chemistry is especially arduous and rare, yet progress exists in characterizing microwave-assisted reactions. This presentation will describe contemporary targets for modern sample preparation approaches for ultra trace elemental analysis and the likelihood that they can be reasonably achieved. (author)

  2. Radioactivity and concentration of some trace elements in sponges distributed along the Syrian coast

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Mamish, S.; Haleem, M. A.; Ammar, I.

    2009-07-01

    natural and artificial radionuclides ( 210 Po, 210 Pb, 40 K, 137 Cs, 234 U, 238 U) and concentration of some trace elements (Zn, Cu, Pb, Cd) in several types of sponges distributed along the Syrian coast have been studied. The samples were collected from four stations distributed at the Syrian coast (Al-Basset, Lattakia, Banise, Tartous). Concentration factors (CF) for the studied radionuclides and trace elements have been calculated in order to determine the sponges types to be used as biomonitors for the radionuclides and trace elements. (authors)

  3. Association between Dietary Share of Ultra-Processed Foods and Urinary Concentrations of Phytoestrogens in the US.

    Science.gov (United States)

    Martínez Steele, Eurídice; Monteiro, Carlos A

    2017-02-28

    The aim of this study was to examine the relationship between dietary contribution of ultra-processed foods and urinary phytoestrogen concentrations in the US. Participants from cross-sectional 2009-2010 National Health and Nutrition Examination Survey aged 6+ years, selected to measure urinary phytoestrogens and with one 24-h dietary recall were evaluated (2692 participants). Food items were classified according to NOVA (a name, not an acronym), a four-group food classification based on the extent and purpose of industrial food processing. Ultra-processed foods are formulations manufactured using several ingredients and a series of processes (hence "ultra-processed"). Most of their ingredients are lower-cost industrial sources of dietary energy and nutrients, with additives used for the purpose of imitating sensorial qualities of minimally processed foods or of culinary preparations of these foods. Studied phytoestrogens included lignans (enterolactone and enterodiol) and isoflavones (genistein, daidzein, O -desmethylangolensin and equol). Gaussian regression was used to compare average urinary phytoestrogen concentrations (normalized by creatinine) across quintiles of energy share of ultra-processed foods. Models incorporated survey sample weights and were adjusted for age, sex, race/ethnicity, family income, and education, among other factors. Adjusted enterodiol geometric means decreased monotonically from 60.6 in the lowest quintile to 35.1 µg/g creatinine in the highest, while adjusted enterolactone geometric means dropped from 281.1 to 200.1 across the same quintiles, respectively. No significant linear trend was observed in the association between these quintiles and isoflavone concentrations. This finding reinforces the existing evidence regarding the negative impact of ultra-processed food consumption on the overall quality of the diet and expands it to include non-nutrients such as lignans.

  4. Assessment of concentrations of trace and toxic heavy metals in soil ...

    African Journals Online (AJOL)

    This study reports on determination of concentrations of trace and toxic heavy metals in soil and vegetables grown near of Manyoni uranium deposit. Soil and vegetable samples were collected from five sites namely Mitoo Mbuga, farming area, Miyomboni, Tambukareli and near water pump. The concentrations of heavy ...

  5. Impact of trace metal concentrations on coccolithophore growth and morphology: laboratory simulations of Cretaceous stress

    Science.gov (United States)

    Faucher, Giulia; Hoffmann, Linn; Bach, Lennart T.; Bottini, Cinzia; Erba, Elisabetta; Riebesell, Ulf

    2017-07-01

    The Cretaceous ocean witnessed intervals of profound perturbations such as volcanic input of large amounts of CO2, anoxia, eutrophication and introduction of biologically relevant metals. Some of these extreme events were characterized by size reduction and/or morphological changes of a few calcareous nannofossil species. The correspondence between intervals of high trace metal concentrations and coccolith dwarfism suggests a negative effect of these elements on nannoplankton biocalcification processes in past oceans. In order to test this hypothesis, we explored the potential effect of a mixture of trace metals on growth and morphology of four living coccolithophore species, namely Emiliania huxleyi, Gephyrocapsa oceanica, Pleurochrysis carterae and Coccolithus pelagicus. The phylogenetic history of coccolithophores shows that the selected living species are linked to Mesozoic species showing dwarfism under excess metal concentrations. The trace metals tested were chosen to simulate the environmental stress identified in the geological record and upon known trace metal interactions with living coccolithophore algae.Our laboratory experiments demonstrated that elevated trace metal concentrations, similarly to the fossil record, affect coccolithophore algae size and/or weight. Smaller coccoliths were detected in E. huxleyi and C. pelagicus, while coccoliths of G. oceanica showed a decrease in size only at the highest trace metal concentrations. P. carterae coccolith size was unresponsive to changing trace metal concentrations. These differences among species allow discriminating the most- (P. carterae), intermediate- (E. huxleyi and G. oceanica) and least-tolerant (C. pelagicus) taxa. The fossil record and the experimental results converge on a selective response of coccolithophores to metal availability.These species-specific differences must be considered before morphological features of coccoliths are used to reconstruct paleo-chemical conditions.

  6. Impact of trace metal concentrations on coccolithophore growth and morphology: laboratory simulations of Cretaceous stress

    Directory of Open Access Journals (Sweden)

    G. Faucher

    2017-07-01

    Full Text Available The Cretaceous ocean witnessed intervals of profound perturbations such as volcanic input of large amounts of CO2, anoxia, eutrophication and introduction of biologically relevant metals. Some of these extreme events were characterized by size reduction and/or morphological changes of a few calcareous nannofossil species. The correspondence between intervals of high trace metal concentrations and coccolith dwarfism suggests a negative effect of these elements on nannoplankton biocalcification processes in past oceans. In order to test this hypothesis, we explored the potential effect of a mixture of trace metals on growth and morphology of four living coccolithophore species, namely Emiliania huxleyi, Gephyrocapsa oceanica, Pleurochrysis carterae and Coccolithus pelagicus. The phylogenetic history of coccolithophores shows that the selected living species are linked to Mesozoic species showing dwarfism under excess metal concentrations. The trace metals tested were chosen to simulate the environmental stress identified in the geological record and upon known trace metal interactions with living coccolithophore algae.Our laboratory experiments demonstrated that elevated trace metal concentrations, similarly to the fossil record, affect coccolithophore algae size and/or weight. Smaller coccoliths were detected in E. huxleyi and C. pelagicus, while coccoliths of G. oceanica showed a decrease in size only at the highest trace metal concentrations. P. carterae coccolith size was unresponsive to changing trace metal concentrations. These differences among species allow discriminating the most- (P. carterae, intermediate- (E. huxleyi and G. oceanica and least-tolerant (C. pelagicus taxa. The fossil record and the experimental results converge on a selective response of coccolithophores to metal availability.These species-specific differences must be considered before morphological features of coccoliths are used to reconstruct paleo-chemical conditions.

  7. N-myc oncogene amplification is correlated to trace metal concentrations in neuroblastoma cultured cells

    International Nuclear Information System (INIS)

    Gouget, B.; Sergeant, C.; Benard, J.; Llabador, Y.; Simonoff, M.

    2000-01-01

    N-myc oncogene amplification is a powerful predictor of aggressive behavior of neuroblastoma (NB), the most common solid tumor of the early childhood. Since N-myc overexpression - subsequent to amplification - determines a phenotype of invasiveness and metastatic spreading, it is assumed that N-myc amplified neuroblasts synthesize zinc metalloenzymes leading to tumor invasion and formation of metastases. In order to test a possible relation between N-myc oncogene amplification and trace metal contents in human NB cells, Fe, Cu and Zn concentrations have been measured by nuclear microprobe analysis in three human neuroblastoma cell lines with various degrees of N-myc amplification. Elemental determinations show uniform distribution of trace metals within the cells, but variations of intracellular trace metal concentrations with respect to the degree of N-myc amplification are highly dependent on the nature of the element. Zinc concentration is higher in both N-myc amplified cell lines (IMR-32 and IGR-N-91) than in the non-amplified cells (SK-N-SH). In contrast, intracellular iron content is particularly low in N-myc amplified cell lines. Moreover, copper concentrations showed an increase with the degree of N-myc amplification. These results indicate that a relationship exists between intracellular trace metals and N-myc oncogene amplification. They further suggest that trace metals very probably play a determinant role in mechanisms of the neuroblastoma invasiveness

  8. Temperature and Concentration Traces of Spray Flows During Motion in a Flame

    Directory of Open Access Journals (Sweden)

    Antonov Dmitry V.

    2016-01-01

    Full Text Available Heat and mass transfer models are developed on the base of experimental data and using Ansys Fluent software. These models allow prediction of the temperature and concentration traces of droplets. Transfer mechanisms of water droplets from different flames of flammable liquid (ethanol, kerosene И benzine with temperature gases 450–850 К are analyzed. The paper considers aerosol flows with droplets sizes of 0.04–0.4 mm and concentration of 3.8·10-5 –10.3·10-5 m3 of droplets/m3 of gas. The maximum gas temperature reduction in the trace of a moving liquid is ranged from 850 K to 600 K. The times of keeping the low temperature of the gas-vapor mixture in the droplets trace are from 13 s to 25 s relative to the initial gas temperature.

  9. Trace element concentrations in human bone using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    El-Amri, F.A.; El-Kabroun, M.A.R.

    1997-01-01

    Instrumental neutron activation analysis has been applied to analyze 23 bone samples obtained from Libyan patient aged (3-80) years for the study of the concentration levels of trace elements Ba, Br, Ca, Fe, Sr and Zn and their concentration patterns regarding to the age and sex of the patients. (author)

  10. Silica Gel Coated Spherical Micro resonator for Ultra-High Sensitivity Detection of Ammonia Gas Concentration in Air.

    Science.gov (United States)

    Mallik, Arun Kumar; Farrell, Gerald; Liu, Dejun; Kavungal, Vishnu; Wu, Qiang; Semenova, Yuliya

    2018-01-26

    A silica gel coated microsphere resonator is proposed and experimentally demonstrated for measurements of ammonia (NH 3 ) concentration in air with ultra-high sensitivity. The optical properties of the porous silica gel layer change when it is exposed to low (parts per million (ppm)) and even ultra-low (parts per billion (ppb)) concentrations of ammonia vapor, leading to a spectral shift of the WGM resonances in the transmission spectrum of the fiber taper. The experimentally demonstrated sensitivity of the proposed sensor to ammonia is estimated as 34.46 pm/ppm in the low ammonia concentrations range from 4 ppm to 30 ppm using an optical spectrum analyser (OSA), and as 800 pm/ppm in the ultra-low range of ammonia concentrations from 2.5 ppb to 12 ppb using the frequency detuning method, resulting in the lowest detection limit (by two orders of magnitude) reported to date equal to 0.16 ppb of ammonia in air. In addition, the sensor exhibits excellent selectivity to ammonia and very fast response and recovery times measured at 1.5 and 3.6 seconds, respectively. Other attractive features of the proposed sensor are its compact nature, simplicity of fabrication.

  11. Ultra-trace determination of Persistent Organic Pollutants in Artic ice using stir bar sorptive extraction and gas chromatography coupled to mass spectrometry

    OpenAIRE

    Lacorte Bruguera, Silvia; Quintana, Jordi; Tauler, Romà; Ventura, Francesc; Tovar-Sánchez, Antonio; Duarte, Carlos M.

    2010-01-01

    This study presents the optimization and application of an analytical method based on the use of stirbarsorptiveextraction (SBSE) gaschromatographycoupled to massspectrometry (GC–MS) for the ultra-trace analysis of POPs (PersistentOrganicPollutants) in Arctic ice. In a first step, the mass-spectrometry conditions were optimized to quantify 48 compounds (polycyclic aromatic hydrocarbons, brominated diphenyl ethers, chlorinated biphenyls, and organochlorinated pesticides) at the low pg/L level....

  12. Trace analysis of semiconductor materials

    CERN Document Server

    Cali, J Paul; Gordon, L

    1964-01-01

    Trace Analysis of Semiconductor Materials is a guidebook concerned with procedures of ultra-trace analysis. This book discusses six distinct techniques of trace analysis. These techniques are the most common and can be applied to various problems compared to other methods. Each of the four chapters basically includes an introduction to the principles and general statements. The theoretical basis for the technique involved is then briefly discussed. Practical applications of the techniques and the different instrumentations are explained. Then, the applications to trace analysis as pertaining

  13. Effect of soil moisture on trace elements concentrations using ...

    African Journals Online (AJOL)

    Portable X-ray fluorescence (PXRF) technology can offer rapid and cost-effective determination of the trace elements concentrations in soils. The aim of this study was to assess the influence of soil moisture content under different condition on PXRF measurement quality. For this purpose, PXRF was used to evaluate the soil ...

  14. Association between Dietary Share of Ultra-Processed Foods and Urinary Concentrations of Phytoestrogens in the US

    Directory of Open Access Journals (Sweden)

    Eurídice Martínez Steele

    2017-02-01

    Full Text Available The aim of this study was to examine the relationship between dietary contribution of ultra-processed foods and urinary phytoestrogen concentrations in the US. Participants from cross-sectional 2009–2010 National Health and Nutrition Examination Survey aged 6+ years, selected to measure urinary phytoestrogens and with one 24-h dietary recall were evaluated (2692 participants. Food items were classified according to NOVA (a name, not an acronym, a four-group food classification based on the extent and purpose of industrial food processing. Ultra-processed foods are formulations manufactured using several ingredients and a series of processes (hence “ultra-processed”. Most of their ingredients are lower-cost industrial sources of dietary energy and nutrients, with additives used for the purpose of imitating sensorial qualities of minimally processed foods or of culinary preparations of these foods. Studied phytoestrogens included lignans (enterolactone and enterodiol and isoflavones (genistein, daidzein, O-desmethylangolensin and equol. Gaussian regression was used to compare average urinary phytoestrogen concentrations (normalized by creatinine across quintiles of energy share of ultra-processed foods. Models incorporated survey sample weights and were adjusted for age, sex, race/ethnicity, family income, and education, among other factors. Adjusted enterodiol geometric means decreased monotonically from 60.6 in the lowest quintile to 35.1 µg/g creatinine in the highest, while adjusted enterolactone geometric means dropped from 281.1 to 200.1 across the same quintiles, respectively. No significant linear trend was observed in the association between these quintiles and isoflavone concentrations. This finding reinforces the existing evidence regarding the negative impact of ultra-processed food consumption on the overall quality of the diet and expands it to include non-nutrients such as lignans.

  15. A molecularly imprinted electrochemiluminescence sensor based on the mimetic enzyme catalytic effect for ultra-trace Ni2+ determination.

    Science.gov (United States)

    Yang, Bin; Li, Jianping; Zhang, Lianming; Xu, Guobao

    2016-10-21

    A novel molecularly imprinted polymer (MIP) electrochemiluminescence (MIP-ECL) sensor was developed for the highly sensitive and selective determination of ultra-trace levels of Ni 2+ . The complex Ni 2+ -dimethylglyoxime (Ni-DMG) was chosen as the template molecule to construct the MIP and then acted as a mimetic enzyme to catalyse the oxidisation of luminol to enhance the ECL signal. When the imprinted cavities were occupied by Ni-DMG in the rebinding process, the ECL intensities produced by the luminol-H 2 O 2 ECL system on the MIP-modified electrode surface increased with increased concentration of the Ni-DMG complex. The highly sensitive determination of Ni 2+ was achieved through a catalytic reaction. This technique could be used for the quantitative analysis of Ni 2+ with concentrations from 3.0 × 10 -12 mol L -1 to 6.0 × 10 -9 mol L -1 . The detection limit was 1.01 × 10 -12 mol L -1 , which is much lower than that reported previously. In addition, the allowable amounts of interference ions in the MIP-ECL sensor were higher than that in other common molecularly imprinted sensors because of its excellent recognition of 3D cavity-to-complex molecules and ligand-to-metal ions. This method was successfully used to determine Ni 2+ in real samples, such as apples, carrots and grapes, and has been proven feasible for practical applications.

  16. Concentration of 24 Trace Elements in Human Heart Tissue Determined by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wester, P O

    1964-06-15

    By means of neutron-activation analysis, human heart tissue from autopsy of 20 victims of traumatic accidents has been investigated with respect to the concentration of 24 different trace elements. A recently developed ion-exchange technique combined with gamma spectrometry has been used, which permits simultaneous determination of a large number of trace elements. The following trace elements have been determined quantitatively: Ag, As, Au, Ba, Br; Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Pt, Rb, Sb, Se, Se, Sm, Zn, W. In some heart samples, Hf and Os were determined qualitatively. The mean and standard deviation are given for the elements Cu, Fe, Se and Zn, Since none of the other quantitatively determined trace elements were normally distributed, the median is given as the central value. When possible, comparisons with values from other investigations have been made. No marked differences in the trace-element concentrations with age or sex could be detected.

  17. Concentration of 24 Trace Elements in Human Heart Tissue Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1964-06-01

    By means of neutron-activation analysis, human heart tissue from autopsy of 20 victims of traumatic accidents has been investigated with respect to the concentration of 24 different trace elements. A recently developed ion-exchange technique combined with gamma spectrometry has been used, which permits simultaneous determination of a large number of trace elements. The following trace elements have been determined quantitatively: Ag, As, Au, Ba, Br; Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Pt, Rb, Sb, Se, Se, Sm, Zn, W. In some heart samples, Hf and Os were determined qualitatively. The mean and standard deviation are given for the elements Cu, Fe, Se and Zn, Since none of the other quantitatively determined trace elements were normally distributed, the median is given as the central value. When possible, comparisons with values from other investigations have been made. No marked differences in the trace-element concentrations with age or sex could be detected

  18. Concentrations of trace elements in human tissues and relation of ratios of mutual metals to the human health

    International Nuclear Information System (INIS)

    Ling-wei, X.; Shao-xian, L.; Xiao-juan, Z.

    1989-01-01

    According to the experimental results, the concentrations and concentrations in order, of trace elements in human tissues among Changsha's People in China are reported. The authors particularly present that the ratios of mutual metals (M/N) in normal physiological tissues and fluids are very important factors which indicate the metabolic situations of trace elements in the body and as the indices which evaluate the situation of human health. (M and N mean the concentrations of different trace elements in the tissues or fluids, respectively.) Up to now, it is still an interesting field to study the functions of trace elements for the human health. There are previously some reports about the concentrations of trace elements in normal physiological tissues/ or organs and fluids of human body. These provide very valuable data for biological medicine. In the study presented atomic absorption method was adopted in order to determine the concentrations of Zn, Cu, Mn, Ni, Pb and Cd in human tissues (liver, spleen, kidney, bone, lung, pancreas, heart and artery and muscle) at autopsy. The authors suggest that trace elements, are contained in the body in an aproportional way, in normal physiological tissues and fluids, and the ratios may directly indicate metabolic situation of trace elements in the body which further reveal the mystery of trace elements for human health. Therefore, the ratios M/N as an indicator of health is more proper than that only using concentrations of trace elements. Schroeder (1973) reported that incidence of heart disease is related to the imbalance of ration Zn/Cd and Zn/Cu rather than the concentrations of Zn, Cd, Cu, and the intellectual development also depends on the proper proportion among copper, cadmium, lead, zinc in the body

  19. SOLFAST, a Ray-Tracing Monte-Carlo software for solar concentrating facilities

    International Nuclear Information System (INIS)

    Roccia, J P; Piaud, B; Coustet, C; Caliot, C; Guillot, E; Flamant, G; Delatorre, J

    2012-01-01

    In this communication, the software SOLFAST is presented. It is a simulation tool based on the Monte-Carlo method and accelerated Ray-Tracing techniques to evaluate efficiently the energy flux in concentrated solar installations.

  20. PIXE analysis of trace elements in relation to chlorophyll concentration in Plantago ovata Forsk

    International Nuclear Information System (INIS)

    Saha, Priyanka; Sen Raychaudhuri, Sarmistha; Chakraborty, Anindita; Sudarshan, Mathummal

    2010-01-01

    Plantago ovata Forsk - an economically important medicinal plant - was analyzed for trace elements and chlorophyll in a study of the effects of gamma radiation on physiological responses of the seedlings. Proton-induced X-ray emission (PIXE) technique was used to quantify trace elements in unirradiated and gamma-irradiated plants at the seedling stage. The experiments revealed radiation-induced changes in the trace element and chlorophyll concentrations.

  1. Effects of trace metal concentrations on the growth of the coral endosymbiont Symbiodinium kawagutii

    Directory of Open Access Journals (Sweden)

    Irene Barra Rodriguez

    2016-02-01

    Full Text Available Symbiodinium is an indispensable endosymbiont in corals and the most important primary producer in coral reef ecosystems. During the past decades, coral bleaching attributed to the disruption of the symbiosis has frequently occurred resulting in reduction of coral reef coverage globally. Growth and proliferation of corals require some specific trace metals that are essential components of pertinent biochemical processes, such as in photosynthetic systems and electron transport chains. In addition, trace metals are vital in the survival of corals against oxidative stress because these metals serve as enzymatic cofactors in antioxidative defense mechanisms. The basic knowledge about trace metal requirement of Symbiodinium is lacking. Here we show that the requirement of S. kawagutii for antioxidant-associated trace metals exhibits the following order: Fe >> Cu/Zn/Mn >> Ni. In growth media with Cu, Zn, Mn and varying Fe concentrations, we observed that Cu, Zn and Mn cellular quotas were inversely related to Fe concentrations. In the absence of Cu, Zn and Mn, growth rates increased with increasing inorganic Fe concentrations up to 1250 pM, indicating the relatively high Fe requirement for Symbiodinium growth and potential functional complementarity of these metals. These results demonstrate the relative importance of trace metals to sustain Symbiodinium growth and a potential metal interreplacement strategy in Symbiodinium to ensure survival of coral reefs in an oligotrophic and stressful environment.

  2. Ultra-trace monitoring of copper in environmental and biological samples by inductively coupled plasma atomic emission spectrometry after separation and preconcentration by using octadecyl silica membrane disks modified by a new schiff's base

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Ganjali

    2004-04-01

    Full Text Available Ultra-trace amounts of Cu(II were separated and preconcentrated by solid phase extraction on octadecyl-bonded silica membrane disks modified with a new Schiff,s base (Bis- (2-Hydroxyacetophenone -2,2-dimethyl-1,3-propanediimine (SBTD followed by elution and inductively coupled plasma atomic emission spectrometric detection. The method was applied as a separation and detection method for copper(II in environmental and biological samples. Extraction efficiency and the influence of sample matrix, flow rate, pH, and type and minimum amount of stripping acid were investigated. The concentration factor and detection limit of the proposed method are 500 and 12.5 pg mL-1, respectively.

  3. Modeling Trace Element Concentrations in the San Francisco Bay Estuary from Remote Measurement of Suspended Solids

    Science.gov (United States)

    Press, J.; Broughton, J.; Kudela, R. M.

    2014-12-01

    Suspended and dissolved trace elements are key determinants of water quality in estuarine and coastal waters. High concentrations of trace element pollutants in the San Francisco Bay estuary necessitate consistent and thorough monitoring to mitigate adverse effects on biological systems and the contamination of water and food resources. Although existing monitoring programs collect annual in situ samples from fixed locations, models proposed by Benoit, Kudela, & Flegal (2010) enable calculation of the water column total concentration (WCT) and the water column dissolved concentration (WCD) of 14 trace elements in the San Francisco Bay from a more frequently sampled metric—suspended solids concentration (SSC). This study tests the application of these models with SSC calculated from remote sensing data, with the aim of validating a tool for continuous synoptic monitoring of trace elements in the San Francisco Bay. Using HICO imagery, semi-analytical and empirical SSC algorithms were tested against a USGS dataset. A single-band method with statistically significant linear fit (p Arsenic, Iron, and Lead in the southern region of the Bay were found to exceed EPA water quality criteria for human health and aquatic life. The results of this study demonstrate the potential of monitoring programs using remote observation of trace element concentrations, and provide the foundation for investigation of pollutant sources and pathways over time.

  4. The determination of some trace elements in sulphide concentrates by spectrophotometry

    International Nuclear Information System (INIS)

    Shelton, B.J.; Komarkova, E.; Josephson, M.; Cook, E.B.T.; Dixon, K.

    1977-01-01

    The report describes the determination of trace amounts (as low as 1 to 10 p.p.m. depending on the element) of arsenic, germanium, molybdenum, nickel, phosphorus, selenium, tellurium, tin, and titanium in sulphide concentrates. The proposed methods, which are detailed in the appendices, are adaptations of established procedures that were modified to allow for the complex nature of the concentrates to be analysed

  5. Trace elements release from volcanic ash to seawater. Natural concentrations in Central Mediterranean sea

    Science.gov (United States)

    Randazzo, L. A.; Censi, P.; Saiano, F.; Zuddas, P.; Aricò, P.; Mazzola, S.

    2009-04-01

    Distributions and concentrations of many minor and trace elements in epicontinental basins, as Mediterranean Sea, are mainly driven to atmospheric fallout from surroundings. This mechanism supplies an estimated yearly flux of about 1000 kg km-2 of terrigenous matter of different nature on the whole Mediterranean basin. Dissolution of these materials and processes occurring at solid-liquid interface along the water column drive the distributions of many trace elements as V, Cr, Mn, Co, Cu, and Pb with contents ranging from pmol l-1 (Co, Cd, Pb) to nmol l-1 scale in Mediterranean seawater, with some local differences in the basin. The unwinding of an oceanographic cruise in the coastal waters of Ionian Sea during the Etna's eruptive activity in summer 2001 led to the almost unique chance to test the effects of large delivery of volcanic ash to a coastal sea water system through the analyses of distribution of selected trace elements along several seawater columns. The collection of these waters and their analyses about V, Cr, Mn, Co, Cu, and Pb contents evidenced trace element concentrations were always higher (about 1 order of magnitude at least) than those measured concentrations in the recent past in Mediterranean seawater, apart from Pb. Progressive increase of concentrations of some elements with depth, sometimes changing in a "conservative" behaviour without any clear reason and the observed higher concentrations required an investigation about interaction processes occurring at solid-liquid interface between volcanic ash and seawater along water columns. This investigation involving kinetic evaluation of trace element leaching to seawater, was carried out during a 6 months time period under laboratory conditions. X-ray investigations, SEM-EDS observations and analyses on freshly-erupted volcanic ash evidenced formation of alteration clay minerals onto glass fraction surfaces. Chemical analyses carried out on coexisting liquid phase demonstrated that trace

  6. Concentration of Trace Metals in Boreholes in the Ankobra Basin ...

    African Journals Online (AJOL)

    Fiifi Baidoo

    Most of the boreholes with high trace metal concentrations were located in and around the Bawdie-Bogoso-Prestea area. Introduction. Ankobra basin is one of the main mining areas in Ghana. The major minerals mined in this area include gold, manganese, bauxite and diamond. Gold mining in this basin dates about 500 ...

  7. On-line sample-pre-treatment schemes for trace-level determinations of metals by coupling flow injection or sequential injection with ICP-MS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    a polytetrafluoroethylene (PTFE) knotted reactor (KR), solvent extraction-back extraction and hydride/vapor generation. It also addresses a novel, robust approach, whereby the protocol of SI-LOV-bead injection (BI) on-line separation and pre-concentration of ultra-trace levels of metals by a renewable microcolumn...

  8. Trace concentrations of vitamin E protect radiation crosslinked UHMWPE from oxidative degradation.

    Science.gov (United States)

    Kurtz, S M; Dumbleton, J; Siskey, R S; Wang, A; Manley, M

    2009-08-01

    The effect of very low concentrations of Vitamin E on the stability and mechanical behavior of UHMWPE remains unknown. We tested the hypothesis that the oxidation resistance of Vitamin E-blended UHMWPE would be influenced by trace doses of antioxidant, resin, and radiation treatment. Trace concentrations (Vitamin E) were blended separately with GUR 1020 and 1050 resins and molded into disks. From each disk, three groups of 10 mm thick blocks were machined: (1) no irradiation (control); (2) 30 kGy of gamma irradiation in nitrogen; and (3) 75 kGy of gamma irradiation in air. Specimens were subjected to three aging protocols: (a) no aging (control); (b) two weeks and (c) four weeks of accelerated aging in accordance with ASTM F 2003 (i.e., 70 degrees C and 5 atm oxygen). The minimum concentration of Vitamin E needed to stabilize UHMWPE during our accelerated tests depended upon the method of radiation processing. For the 30 and 75 kGy irradiated materials, the addition of 125 ppm or more Vitamin E was sufficient to maintain baseline mechanical and chemical properties through two weeks of accelerated aging. For these groups, the addition of 375 ppm or 500 ppm, respectively, was necessary to maintain baseline mechanical and chemical properties throughout the four-week accelerated aging period. UHMWPE resin molecular weight did not have an effect on oxidation behavior. The results of this experiment therefore supported our hypotheses that trace concentrations of Vitamin E, coupled with radiation treatment-but not resin grade-influence the mechanical and oxidative degradation behavior of UHMWPE.

  9. Extraction chromatography of trace concentrations of mercury(II)

    International Nuclear Information System (INIS)

    Smejkal, Z.; Zepla, Z.; Tauferova, J.

    1984-01-01

    The separation of trace amounts of mercury(II) from aqueous solutions has been studied in mixtures of other metal ions (concentration Hg(II) 10 μg/100 ml). The Hg(II) separation was carried out in glass columns filled with Synachrom E-5 carrier impregnanted with a solution of bis(diethyldithiocarbamate)-copper(II) in a mixture of 1.2-dichlorbenzene and cyclohexane (1:1). Trapped Hg(II) was eluted by HCl. The course of the chromatographic process was followed by gamma spectroscopy. Separation yields of Hg(II) were about 90%. (author)

  10. Sequential injection/bead injection lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by ETAAS and ICPMS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald; Miró, Manuel

    2003-01-01

    are focused on the applications of SI-BI-LOV protocols for on-line microcolumn based solid phase extraction of ultra-trace levels of heavy metals, employing the so-called renewable surface separation and preconcentration manipulatory scheme. Two types of sorbents have been employed as packing material...

  11. Efficient Time-Domain Ray-Tracing Technique for the Analysis of Ultra-Wideband Indoor Environments including Lossy Materials and Multiple Effects

    Directory of Open Access Journals (Sweden)

    F. Saez de Adana

    2009-01-01

    Full Text Available This paper presents an efficient application of the Time-Domain Uniform Theory of Diffraction (TD-UTD for the analysis of Ultra-Wideband (UWB mobile communications for indoor environments. The classical TD-UTD formulation is modified to include the contribution of lossy materials and multiple-ray interactions with the environment. The electromagnetic analysis is combined with a ray-tracing acceleration technique to treat realistic and complex environments. The validity of this method is tested with measurements performed inside the Polytechnic building of the University of Alcala and shows good performance of the model for the analysis of UWB propagation.

  12. Ultra-wide detectable concentration range of GMR biosensors using Fe{sub 3}O{sub 4} microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Jie [College of Physics, Key Laboratory of Photonics Materials and Technology in Universities of Shandong, and Laboratory of Fiber Materials and Modern Textile, the Growing Base for State Key Laboratory, Qingdao University, Qingdao 266071 (China); School of Chemical Science and Engineering, Qingdao University, Qingdao 266071 (China); Li, Qiang [College of Physics, Key Laboratory of Photonics Materials and Technology in Universities of Shandong, and Laboratory of Fiber Materials and Modern Textile, the Growing Base for State Key Laboratory, Qingdao University, Qingdao 266071 (China); Zong, Weihua [Shandong Provincial Key Laboratory of Industrial Control Technology, Qingdao University, Qingdao 266071 (China); Zhang, Yongcheng [College of Physics, Key Laboratory of Photonics Materials and Technology in Universities of Shandong, and Laboratory of Fiber Materials and Modern Textile, the Growing Base for State Key Laboratory, Qingdao University, Qingdao 266071 (China); Li, Shandong, E-mail: lishd@qdu.edu.cn [College of Physics, Key Laboratory of Photonics Materials and Technology in Universities of Shandong, and Laboratory of Fiber Materials and Modern Textile, the Growing Base for State Key Laboratory, Qingdao University, Qingdao 266071 (China); National Laboratory of Solid State Microstructures, Nanjing University, Nanjing 210093 (China)

    2016-11-01

    Exchange-biased GMR sensors were employed for biodetection using a DC in-plane measuring method and a magnetic label of Fe{sub 3}O{sub 4} microspheres. It was revealed that an ultra-wide concentration span covering five orders from 10 ng/mL to 1000 μg/mL was achieved in a home-made biodetection device. The concentration x dependence of output voltage difference |ΔV| between with and without magnetic labels, exhibits nonlinear futures, which undergoes two functions depending on the concentration region. For the low concentration region from 10 ng/mL to 10 μg/mL, a logarithmic relation of |ΔV|=26.3lgx+91.4 fits well, while for the high concentration region, a negative exponential function of |ΔV|=3113(1−e{sup −x/250}) describes the |ΔV|~x relation better. For the former, the “coffee ring” effect, formed during the solvent evaporation, was considered as the main reason for the nonlinear relation. While for the latter with high concentration, the overlap among the particles and the enhanced interaction of the magnetic dipole were responsible for the nonlinear |ΔV|~x relationship. Moreover, the calculated detectable concentration limit is agreed well with the experimental data. - Highlights: • Ultra-wide concentration span covering five orders from 0.01 to 1000 μg/mL. • A logarithmic function well describes the relation of |ΔV|~x at low concentration. • An exponential function well describes the relation of |ΔV|~x at high concentration.

  13. Solid phase extraction of ultra traces silver(I) using octadecyl silica membrane disks modified by 1,3-bis(2-cyanobenzene) triazene (CBT) ligand prior to determination by flame atomic absorption

    International Nuclear Information System (INIS)

    Rofouei, Mohammad Kazem; Payehghadr, Mahmood; Shamsipur, Mojtaba; Ahmadalinezhad, Asieh

    2009-01-01

    A simple, reliable and rapid method for preconcentration and determination of the ultra trace amount of silver using octadecyl silica membrane disk modified by a recently synthesized triazene ligand, 1,3-bis(2-cyanobenzene)triazene (CBT), and flame atomic absorption spectrometry is presented. Various parameters including pH of aqueous solution, flow rates, the amount of ligand and the type of stripping solvents were optimized. The breakthrough volume was greater than 1800 ml with an enrichment factor of more than 360 and 6.0 ng l -1 detection limit. The capacity of the membrane disks modified by 5 mg of the ligand was found to be 1070 μg of silver. The effects of various cationic interferences on the percent recovery of silver ion were studied. The method was successfully applied to the determination of silver ion in different samples, especially determination of ultra trace amount of silver in the presence of large amount of lead.

  14. Solid phase extraction of ultra traces silver(I) using octadecyl silica membrane disks modified by 1,3-bis(2-cyanobenzene) triazene (CBT) ligand prior to determination by flame atomic absorption

    Energy Technology Data Exchange (ETDEWEB)

    Rofouei, Mohammad Kazem, E-mail: rofouei@tmu.ac.ir [Faculty of Chemistry, Tarbiat Moalem University, Tehran (Iran, Islamic Republic of); Payehghadr, Mahmood [Department of Chemistry, Payame Noor University (PNU) (Iran, Islamic Republic of); Shamsipur, Mojtaba [Department of Chemistry, Razi University, Kermanshah (Iran, Islamic Republic of); Ahmadalinezhad, Asieh [Department of Chemistry, Lakehead University, Thunder Bay, Ontario P7B 5E1 (Canada)

    2009-09-15

    A simple, reliable and rapid method for preconcentration and determination of the ultra trace amount of silver using octadecyl silica membrane disk modified by a recently synthesized triazene ligand, 1,3-bis(2-cyanobenzene)triazene (CBT), and flame atomic absorption spectrometry is presented. Various parameters including pH of aqueous solution, flow rates, the amount of ligand and the type of stripping solvents were optimized. The breakthrough volume was greater than 1800 ml with an enrichment factor of more than 360 and 6.0 ng l{sup -1} detection limit. The capacity of the membrane disks modified by 5 mg of the ligand was found to be 1070 {mu}g of silver. The effects of various cationic interferences on the percent recovery of silver ion were studied. The method was successfully applied to the determination of silver ion in different samples, especially determination of ultra trace amount of silver in the presence of large amount of lead.

  15. Ultra-light and flexible pencil-trace anode for high performance potassium-ion and lithium-ion batteries

    Directory of Open Access Journals (Sweden)

    Zhixin Tai

    2017-07-01

    Full Text Available Engineering design of battery configurations and new battery system development are alternative approaches to achieve high performance batteries. A novel flexible and ultra-light graphite anode is fabricated by simple friction drawing on filter paper with a commercial 8B pencil. Compared with the traditional anode using copper foil as current collector, this innovative current-collector-free design presents capacity improvement of over 200% by reducing the inert weight of the electrode. The as-prepared pencil-trace electrode exhibits excellent rate performance in potassium-ion batteries (KIBs, significantly better than in lithium-ion batteries (LIBs, with capacity retention of 66% for the KIB vs. 28% for the LIB from 0.1 to 0.5 A g−1. It also shows a high reversible capacity of ∼230 mAh g−1 at 0.2 A g−1, 75% capacity retention over 350 cycles at 0.4 A g−1and the highest rate performance (based on the total electrode weight among graphite electrodes for K+ storage reported so far. Keywords: Current-collector-free, Flexible pencil-trace electrode, Potassium-ion battery, Lithium-ion battery, Layer-by-layer interconnected architecture

  16. Automatic data acquisition and on-line analysis of trace element concentration in serum samples

    International Nuclear Information System (INIS)

    Lecomte, R.; Paradis, P.; Monaro, S.

    1978-01-01

    A completely automated system has been developed to determine the trace element concentration in biological samples by measuring charged particle induced X-rays. A CDC-3100 computer with ADC and CAMAC interface is employed to control the data collection apparatus, acquire data and perform simultaneously the analysis. The experimental set-up consists of a large square plexiglass chamber in which a commercially available 750H Kodak Carousel is suitably arranged as a computer controlled sample changer. A method of extracting trace element concentrations using reference spectra is presented and an on-line program has been developed to easily and conveniently obtain final results at the end of each run. (Auth.)

  17. Numerical predictions of the separation of heavy components inside the trace gas concentrator

    International Nuclear Information System (INIS)

    Mo, J.D.

    1995-01-01

    The component with a heavier molecular weight can be separated from the one with a lighter molecular weight in a binary mixture by applying an appropriate pressure gradient. A centrifugal force field effectively generates the required pressure gradient and a favorable flow field along the radial direction in a trace gas concentrator for such an application. This paper presents the numerical predictions of the mass separation inside a trace gas concentrator, which enriches Xenon in air. A Navier-Stokes solver in primitive variables using a pressure based algorithm has been applied to solve for the flow fields. Subsequently, the transport equations with a strong centrifugal field are solved for the mass concentration. This study is the continued effort for the proof-of-concept of centrifugal separation of components with a considerable difference in their molecular weight in a binary mixture. The significant effects of rotational speed, flow field, and the geometrical configuration on the mass separation are presented in this paper

  18. Using trace element concentrations in Corbicula fluminea to identify potential sources of contamination in an urban river

    International Nuclear Information System (INIS)

    Loeffler Peltier, Gretchen; Meyer, Judith L.; Jagoe, Charles H.; Hopkins, William A.

    2008-01-01

    We used the biomonitor, Corbicula fluminea, to investigate the contributions of trace elements associated with different point sources and land uses in a large river. Trace elements were analyzed in tissues of clams collected from 15 tributary streams draining five land use or point source types: agriculture, forest, urban, coal-fired power plant (CFPP), and wastewater (WWTP). Clams from forested catchments had elevated Hg concentrations, and concentrations of arsenic and selenium were highest (5.0 ± 0.2 and 13.6 ± 0.9 μg g -1 dry mass (DM), respectively) in clams from CFPP sites. Cadmium concentrations were significantly higher in clams from urban and CFPP sites (4.1 ± 0.2 and 3.6 ± 0.9 μg g -1 DM, respectively). Non-metric multidimensional scaling (NMS) of tissue concentrations in clams clustered at CFPP and forest/agriculture sites at opposite ends of the ordination space, and the distribution of sites was driven by Cu, Zn, Cd, and Hg. - C. fluminea collected downstream of CFPPs had elevated tissue concentrations of trace elements

  19. Behaviour of trace element concentration in human organs in dependence of age and environment

    International Nuclear Information System (INIS)

    Persigehl, M.; Schicha, H.; Kasperek, K.; Feinendegen, L.E.; Kernforschungsanlage Juelich G.m.b.H.

    1977-01-01

    To study the behaviour of trace elements in dependence of age and environment, samples of skin, lung, heart, aorta, kidney, liver and brain were assayed for concentrations of Fe, Zn, Rb, Co, Cr, Se, Sc, Sb, Cs, Al and partly Eu. All samples were dried at 100 deg C for two days. Instrumental neutron-activation analysis was used to determine the element concentrations. The neutron flux was 5 x 10 13 n cm -2 sec -1 . After decay of the short lived radioisotopes, the Al-concentration was measured following a second irradiation of 1 minute and directly comparing with a standard sample. Nearly all element concentrations changed with processing age, but they showed no clear correlation to either parameter assessed. The non-essential elements Se, Sb and Sc were increasingly concentrated in all organs except the skin. Comparing lung samples of patients from highly industrialized regions with those of lesser industrialization, the elements Sc, Al, Sb, Eu and Co were accumulated by a factor of 10 to 100. Thus the concentrations of trace elements in human organism also depend on the degree of industrialization. (T.G.)

  20. Trace and low concentration co2 removal methods and apparatus utilizing metal organic frameworks

    KAUST Repository

    Eddaoudi, Mohamed

    2016-03-10

    In general, this disclosure describes techniques for removing trace and low concentration CO2 from fluids using SIFSIX-n-M MOFs, wherein n is at least two and M is a metal. In some embodiments, the metal is zinc or copper. Embodiments include devices comprising SIFSIX-n-M MOFs for removing CO2 from fluids. In particular, embodiments relate to devices and methods utilizing SIFSIX-n-M MOFs for removing CO2 from fluids, wherein CO2 concentration is trace. Methods utilizing SIFSIX-n-M MOFs for removing CO2 from fluids can occur in confined spaces. SIFSIX-n-M MOFs can comprise bidentate organic ligands. In a specific embodiment, SIFSIX-n-M MOFs comprise pyrazine or dipryidilacetylene ligands.

  1. Concentrations of trace elements in American alligators (Alligator mississippiensis) from Florida, USA.

    Science.gov (United States)

    Horai, Sawako; Itai, Takaaki; Noguchi, Takako; Yasuda, Yusuke; Adachi, Haruki; Hyobu, Yuika; Riyadi, Adi S; Boggs, Ashley S P; Lowers, Russell; Guillette, Louis J; Tanabe, Shinsuke

    2014-08-01

    Concentrations of 28 trace elements (Li, Mg, Al, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Se, Rb, Sr, Mo, Ag, Cd, In, Sn, Sb, Cs, Tl, Hg, Pb, and Bi) in the livers of juvenile and adult American alligators inhabiting two central Florida lakes, Lake Apopka (LA), and Lake Woodruff National Wildlife Refuge (LW) and one lagoon population located in Merritt Island National Wildlife Refuge (MINWR; NASA), were determined. In juveniles from MINWR, concentrations of nine elements (Li, Fe, Ni, Sr, In, Sb, Hg, Pb and Bi) were significantly higher, whereas six elements (V, Fe, As, Sr, Hg and Bi) were elevated in adults (pLA, LW and MINWR were 1770 μg g(-1) DW, 3690 μg g(-1) DW and 5250 μg g(-1) DW, respectively. More than half of the adult specimens from LW and MINWR exhibited elevated hepatic Fe concentrations that exceed the threshold value for toxic effects in donkey, red deer and human. These results prompted us to express our concern on possible exposure and health effects in American alligators by some trace elements derived from NASA activities. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Spatial Gradients in Trace Metal Concentrations in the Surface Microlayer of the Mediterranean Sea

    Directory of Open Access Journals (Sweden)

    Antonio eTovar-Sanchez

    2014-12-01

    Full Text Available The relationship between dust deposition and surface water metal concentrations is poorly understood. Dissolution, solubility, and partitioning reactions of trace metals from dust particles are governed by complex chemical, biological, and physical processes occurring in the surface ocean. Despite that, the role of the sea surface microlayer (SML, a thin, but fundamental component modulating the air-sea exchange of materials has not been properly evaluated. Our study revealed that the SML of the Mediterranean Sea is enriched with bioactive trace metals (i.e., Cd, Co, Cu and Fe, ranging from 8 (for Cd to 1000 (for Fe times higher than the dissolved metal pool in the underlying water column. The highest enrichments were spatially correlated with the atmospheric deposition of mineral particles. Our mass balance results suggest that the SML in the Mediterranean Sea contains about 2 tonnes of Fe. However, we did not detect any trends between the concentrations of metals in SML with the subsurface water concentrations and biomass distributions. These findings suggest that future studies are needed to quantify the rate of metal exchange between the SML and the bioavailable pool and that the SML should be considered to better understand the effect of atmospheric inputs on the biogeochemistry of trace metals in the ocean.

  3. Impact of geo-chemical environment of subsurface water on the measurement of ultra trace level of uranium in ground water by adsorptive stripping voltammetry

    International Nuclear Information System (INIS)

    Singhal, R.K.; Preetha, J.; Karpe, Rupali; Ajay Kumar; Hegde, A.G.

    2005-01-01

    During the present work, impacts of cations (Ca 2+ , Mg 2+ , K + ,), anions (Cl -1 , F -1 , and PO 4 3- ) and DOC (Dissolved Organic Carbon) on the measurement of ultra trace level of uranium (VI) in subsurface water by adsorptive stripping voltammetry (AdSV) is studied. The concentrations of these anions, cations and DOC in subsurface water changes due to change in the geo-chemical environment at different locations. In AdSV, concentration of U was determined by forming an uranium-chloranilic acid complex (2,5-dichloro- 3,6-dihydroxy-1,4-benzoquinone). AdSV measurements were carried out in the differential pulse (DP) mode using a pulse amplitude of -50 mV, a pulse time of 30 ms and a potential step of 4 mV. The detection limit, was calculated to 2+ , Mg 2+ , K + ) and anions (Cl -1 , F -1 , and PO 4 3- ) was carried out by using Ion Chromatography. Ground water samples were spiked with varying degree of cations, anions and DOC (dissolved organic carbon). DOC in ground waters were measured by Total Organic Carbon (TOC) analyzer. Various experiments show that analysis of uranium in the concentration range of 2+ , Mg 2+ , K + , Cl -1 , F -1 , and PO 4 3- . In case of DOC there is no interference observed in the concentration range of 0.02-15 ppm but beyond 15 ppm the concentration of uranium decrease sharply. Further, if DOC exceeded 16 ppm it was not possible to do the analysis of uranium by AdSV without destruction of DOC, as DOC is surface active organic compound and accumulates on Hg electrode preferentially over uranium-chloroanailic complex. (author)

  4. HAIR HEAVY METAL AND ESSENTIAL TRACE ELEMENT CONCENTRATION IN CHILDREN WITH AUTISM SPECTRUM DISORDER.

    Science.gov (United States)

    Tabatadze, T; Zhorzholiani, L; Kherkheulidze, M; Kandelaki, E; Ivanashvili, T

    2015-11-01

    Our study aims evaluation of level of essential trace elements and heavy metals in the hair samples of children with autistic spectrum disorder (ASD) and identification of changes that are associated with autistic spectrum disorders. Case-control study was conducted at Child Development Center of Iashvili Children's Central Hospital (LD).We studied 60 children aged from 4 to 5 years old. The concentrations of 28 elements among (Ca,Zn, K, Fe, Cu, Se, Mn, Cr, S, Br, Cl, Co, Ag, V, Ni, Rb, Mo, Sr, Ti, Ba, Pb, As, Hg, Cd, Sb, Zr, Sn, Bi) them trace elements and toxic metals) were determined in scalp hair samples of children (n=30) with autistic spectrum disorder (ASD) and from control group of healthy children (n=30) with matched sex and age. Micro-elemental status was detected in the hair, with roentgen-fluorescence spectrometer method (Method MBИ 081/12-4502-000, Apparatus ALVAX- CIP, USA - UKRAIN) .To achieve the similarity of study and control groups, pre and postnatal as well as family and social history were assessed and similar groups were selected. Children with genetic problems, malnourished children, children from families with social problems were excluded from the study. The diagnosis of ASD were performed by pediatrician and psychologist (using M-CHAT and ADOS) according to DSM IV (Diagnostic and Statistical Manual of Mental Disorders from the American Psychiatric association) criteria. The study was statistically analyzed using computer program SPSS 19. Deficiencies of essential trace microelements revealed in both group, but there was significant difference between control and studied groups. The most deficient element was zinc (92% in target and 20% in control), then - manganese (55% and 8%) and selenium (38% and 4%). In case of cooper study revealed excess concentration of this element only in target group in 50% of cases. The contaminations to heavy metals were detected in case of lead (78% and 16), mercury (43% and 10%) and cadmium (38% and 8%). The

  5. THE CONCENTRATION OF TRACE ELEMENTS IN SEWAGE SLUDGE FROM WASTEWATER TREATMENT PLANT IN GNIEWINO

    Directory of Open Access Journals (Sweden)

    Julita Karolina Milik

    2017-09-01

    Full Text Available Sewage sludge originated from wastewater treatment plants (WWTP serving rural areas are suggested for agricultural or natural usage. Before, however, sewage sludge is subjected to the several pre-treatments, which involve stabilization, hygienisation and pre-composting. These methods decrease mainly the amount of organic substances and presence of microorganisms, but hardly affects concentrations of heavy metals. The advantages of using sludges as fertilizer for improving and sustaining soil fertility and crop production are many. The addition of sewage sludge to soils could affect potential availability of heavy metals. Trace elements are distributed in the soil in various forms: solid phases, free ions in soil solution, soluble organic-mineral complexes, or adsorbed on colloidal particles. In the study the concentrations of trace elements (Pb, Cd, Cr, Hg, Ni, Zn, Al, As, Se, B, Ba, Br, Ca, Cu, Fe, Mn, Na, Ga, Li, Mo, Sr, Mg, K, Ru, Tl, V, U was tested in sewage sludge obtained from (WWTP serving rural areas (PE< 9 000. In each case, the tested sewage sludge was meeting the criteria of stabilization and was used for agriculture and land reclamation purpose. All the samples were collected in 2016 and were subjected to microwave mineralization in a closed system in aqua regia. The total amound of macro and microelements were determined with a ICP-OES. It was found that the total concentrations of trace metals in all of sewage sludge are the same than Polish regulation limit of pollutants for sludge to be used in agriculture. The trace elements (cadmium: 1,16 mg·kg-1/d.m. in polish sewage sludge, respectively, much higher than those in the other countries. As a most prevalent copper and zinc were observed (111,28 mg·kg-1/d.m. and 282,94 mg·kg-1/d.m.. The concentrations of copper in polish sewage sludge are much lower (49-130 mg·kg-1/d.m. than european sewage sludge (522-562 mg·kg-1/d.m.. The two out of tested heavy metals (beryllium, bismuth

  6. Application of l-cystine modified zeolite for preconcentration and determination of ultra-trace levels of cadmium by flame atomic absorption spectrometry.

    Science.gov (United States)

    Rezvani, Seyyed Ahmad; Soleymanpour, Ahmad

    2016-03-04

    A very convenient, sensitive and precise solid phase extraction (SPE) system was developed for enrichment and determination of ultra-trace of cadmium ion in water and plant samples. This method was based on the retention of cadmium(II) ions by l-cystine adsorbed in Y-zeolite and carry out in a packed mini-column. The retained cadmium ions then were eluted and determined by flame atomic absorption spectrometry. The scanning electron microscopy (SEM), powder X-ray diffraction (XRD) and Fourier Transform Infrared (FT-IR) spectroscopy techniques were applied for the characterization of cystine modified zeolite (CMZ). Some experimental conditions affecting the analytical performance such as pH, eluent type, concentration of sample, eluent flow rate and also the presence of interfering ions were investigated. The calibration graph was linear within the range of 0.1-7.5ngmL(-1) and limit of detection was obtained 0.04ngmL(-1) with the preconcentration factor of 400. The relative standard deviation (RSD) was obtained 1.4%, indicating the excellent reproducibility of this method. The proposed method was successfully applied for the extraction and determination of cadmium(II) ion in black tea, cigarette's tobacco and also various water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Trace element concentrations in wild mussels from the coastal area of the southeastern Adriatic, Montenegro

    Directory of Open Access Journals (Sweden)

    Markovic Jelena

    2012-01-01

    Full Text Available The aim of the present investigation was to quantify the levels of trace elements (Zn, Cu, As, Pb, Cd and total Hg in the Mediterranean mussel, Mytilus galloprovincialis (L.. Based on their levels, the quality of Montenegro seawater for future mussel farming was estimated. The mussel M. galloprovincialis (L. was collected from four sites in the Montenegrin costal area in the period of two years to determine trace element concentrations and to classify the quality of the coastal water and possible health risks from its consumption. The mean metal concentrations in the mussels ranged from 133.5-205.9 for Zn, 7.50-14.5 for Cu, 4.42-13.3 for As, 4.70-12.9 for Pb, 1.73-2.41 for Cd and 0.07-0.59 for total Hg in mg/kg dry weight. The levels of toxic metals (except for Pb in the mussels were within the maximum residual levels prescribed by the laws of Montenegro, the EU and the USFDA. In addition, the trace metal concentrations found in the mussels in this study were similar to regional data using this mussel as a biomonitoring agent of seawater quality.

  8. Determination of trace elements concentrations in Grewia tenax plants collected from Darfur Region-Sudan

    International Nuclear Information System (INIS)

    Alzain, H. A; Ebrahim, A. M; Salih, A. M; Ali Altom, M. S.

    2016-01-01

    This study is aimed to determine trace elements concentrations (Ca, Cu, Cr, K,Fe, Mn, Ni, Sr and Zn) in Grewia tenax collected from Darfur state western of Sudan. X- ray fluorescence (X RF) technique was used to determine elements concentration. A series of plant standard reference materials(ISE 2012-1) were used to check the reliability of employed technique by comparing the obtained results with the certified values, to estimate possible factors for correcting the concentration of some elements. The results showed that, X RF is a suitable method for measuring Ca, Cu, K, Fe, Mn, Sr and Zn elements. On the other hand, X RF for Cr and Ni determination in plant samples, these elements have showed a deviation from their certified values. Concentration of Fe was about 35 mg/kg in Grewia tenax samples where as K and Ca showed maximum levels about 16000 and 8500 mg/kg respectively, Cu showed minimum concentration about 10 mg/kg. The effect of geographical location on trace elements concentration in plants has been examined through determination of element in different species of Grewia tenax that collected from different locations in Darfur region. Most of the measured elements showed that there is no significant impact of locations on the difference of element contents.(Author)

  9. Trace element concentrations in barramundi (Lates calcarifer) collected along the coast of Vietnam

    International Nuclear Information System (INIS)

    Tu, Nguyen Phuc Cam; Ha, Nguyen Ngoc; Haruta, Shinsuke; Takeuchi, Ichiro

    2014-01-01

    Highlights: • We analyzed 23 trace elements in barramundi collected along the coast of Vietnam. • Isotope signatures (δ 15 N and δ 13 C) helped us track the feeding habitats of barramundi. • We found clear geographic zone-dependent differences for Mn, As, Sr and Tl. • Consumption of barramundi may be safe for Vietnamese people. - Abstract: We determined concentrations of 23 trace elements (TEs), and stable carbon and nitrogen isotope (δ 13 C and δ 15 N) signatures in barramundi (Lates calcarifer) specimens collected along the coast of Vietnam in the Northern (NCZ), Central (CCZ) and Southern (SCZ) zones in the period 2007–2010. A combination of δ 13 C and δ 15 N signatures provided insight into ontogenetic shifts in barramundi foraging choices. There were clear zone-dependent differences in Mn, As, Sr and Tl concentrations; levels of Tl were highest in the NCZ, As in the CCZ, and Mn and Sr in the SCZ. Lowest concentrations of Rb occurred in the NCZ, Bi was lowest in the CCZ, and Cd and Cs were lowest in the SCZ. δ 15 N values significantly increased with increasing Zn, Se, Sn and Cs. Concentrations of TEs in barramundi from Vietnam were below worldwide guidelines for human consumption

  10. Forensic discrimination of copper wire using trace element concentrations.

    Science.gov (United States)

    Dettman, Joshua R; Cassabaum, Alyssa A; Saunders, Christopher P; Snyder, Deanna L; Buscaglia, JoAnn

    2014-08-19

    Copper may be recovered as evidence in high-profile cases such as thefts and improvised explosive device incidents; comparison of copper samples from the crime scene and those associated with the subject of an investigation can provide probative associative evidence and investigative support. A solution-based inductively coupled plasma mass spectrometry method for measuring trace element concentrations in high-purity copper was developed using standard reference materials. The method was evaluated for its ability to use trace element profiles to statistically discriminate between copper samples considering the precision of the measurement and manufacturing processes. The discriminating power was estimated by comparing samples chosen on the basis of the copper refining and production process to represent the within-source (samples expected to be similar) and between-source (samples expected to be different) variability using multivariate parametric- and empirical-based data simulation models with bootstrap resampling. If the false exclusion rate is set to 5%, >90% of the copper samples can be correctly determined to originate from different sources using a parametric-based model and >87% with an empirical-based approach. These results demonstrate the potential utility of the developed method for the comparison of copper samples encountered as forensic evidence.

  11. Flow-injection chemiluminescence assay for ultra-trace determination of DNA using rhodamine B-Ce(IV)-DNA ternary system in sulfuric acid media

    International Nuclear Information System (INIS)

    Ma Yongjun; Zhou Min; Jin Xiaoyong; Zhang Ziyu; Teng Xiulan; Chen Hui

    2004-01-01

    A novel flow-injection chemiluminescence method for the determination of DNA at ultra-trace level has been established. In 0.8 M sulfuric acid media, the chemiluminescence of the rhodamine B-cerium (IV) or Ce(IV) system is enhanced by DNA, activated previously by imidazole-HCl buffer solution (pH 7.0). The enhanced intensity of chemiluminescence is in proportion to log DNA concentration 1.0x10 -8 to 0.1 μg ml -1 for herring sperm DNA and 2.0x10 -6 to 0.2 μg ml -1 for calf thymus DNA with 3σ detection limits of 8.3x10 -9 μg ml -1 for herring sperm DNA and 3.5x10 -7 μg ml -1 for calf thymus DNA, respectively. The relative standard deviation for 1.0x10 -4 μg ml -1 herring sperm DNA was 0.99% and 2.0x10 -3 μg ml -1 for calf thymus DNA was 1.1% (n=11). Using the optimized system, DNA contents in six synthetic samples has been determined with recoveries of 99.5-109.0%. The possible mechanism has also been studied in this paper

  12. Flow-injection chemiluminescence assay for ultra-trace determination of DNA using rhodamine B-Ce(IV)-DNA ternary system in sulfuric acid media

    Energy Technology Data Exchange (ETDEWEB)

    Ma Yongjun; Zhou Min; Jin Xiaoyong; Zhang Ziyu; Teng Xiulan; Chen Hui

    2004-01-09

    A novel flow-injection chemiluminescence method for the determination of DNA at ultra-trace level has been established. In 0.8 M sulfuric acid media, the chemiluminescence of the rhodamine B-cerium (IV) or Ce(IV) system is enhanced by DNA, activated previously by imidazole-HCl buffer solution (pH 7.0). The enhanced intensity of chemiluminescence is in proportion to log DNA concentration 1.0x10{sup -8} to 0.1 {mu}g ml{sup -1} for herring sperm DNA and 2.0x10{sup -6} to 0.2 {mu}g ml{sup -1} for calf thymus DNA with 3{sigma} detection limits of 8.3x10{sup -9} {mu}g ml{sup -1} for herring sperm DNA and 3.5x10{sup -7} {mu}g ml{sup -1} for calf thymus DNA, respectively. The relative standard deviation for 1.0x10{sup -4} {mu}g ml{sup -1} herring sperm DNA was 0.99% and 2.0x10{sup -3} {mu}g ml{sup -1} for calf thymus DNA was 1.1% (n=11). Using the optimized system, DNA contents in six synthetic samples has been determined with recoveries of 99.5-109.0%. The possible mechanism has also been studied in this paper.

  13. Trace elementary concentration in enamel after dental bleaching using HI-ERDA

    International Nuclear Information System (INIS)

    Added, N.; Rizzutto, M.A.; Curado, J.F.; Francci, C.; Markarian, R.; Mori, M.

    2006-01-01

    Changes of elementary concentrations in dental enamel after a bleaching treatment with different products, is presented, with special focus on the oxygen contribution. Concentrations for Ca, P, O and C and some other trace elements were obtained for enamel of bovine incisor teeth by HI-ERDA measurements using a 35 Cl incident beam and an ionization chamber. Five groups of teeth with five samples each were treated with a different bleaching agents. Each tooth had its crown sectioned in two halves, one for bleaching test and one the other used as a control. Average values of C/Ca, O/Ca, F/Ca enrichment factors were found. The comparison between bleached and non-bleached halves indicates that bleaching treatment did not affect the mineral structure when low-concentration whitening systems were used. The almost constant oxygen concentration in enamel, suggests little changes due to whitening therapy

  14. Trace elementary concentration in enamel after dental bleaching using HI-ERDA

    Science.gov (United States)

    Added, N.; Rizzutto, M. A.; Curado, J. F.; Francci, C.; Markarian, R.; Mori, M.

    2006-08-01

    Changes of elementary concentrations in dental enamel after a bleaching treatment with different products, is presented, with special focus on the oxygen contribution. Concentrations for Ca, P, O and C and some other trace elements were obtained for enamel of bovine incisor teeth by HI-ERDA measurements using a 35Cl incident beam and an ionization chamber. Five groups of teeth with five samples each were treated with a different bleaching agents. Each tooth had its crown sectioned in two halves, one for bleaching test and one the other used as a control. Average values of C/Ca, O/Ca, F/Ca enrichment factors were found. The comparison between bleached and non-bleached halves indicates that bleaching treatment did not affect the mineral structure when low-concentration whitening systems were used. The almost constant oxygen concentration in enamel, suggests little changes due to whitening therapy.

  15. Trace elementary concentration in enamel after dental bleaching using HI-ERDA

    Energy Technology Data Exchange (ETDEWEB)

    Added, N [GFAA, Depto de Fisica Nuclear, IFUSP, University of Sao Paulo, Travessa R da rua do Matao 187, Cidade Universitaria, Caixa Postal 66318, CEP 05508-970 Sao Paulo, SP (Brazil); Rizzutto, M A [GFAA, Depto de Fisica Nuclear, IFUSP, University of Sao Paulo, Travessa R da rua do Matao 187, Cidade Universitaria, Caixa Postal 66318, CEP 05508-970 Sao Paulo, SP (Brazil); Curado, J F [GFAA, Depto de Fisica Nuclear, IFUSP, University of Sao Paulo, Travessa R da rua do Matao 187, Cidade Universitaria, Caixa Postal 66318, CEP 05508-970 Sao Paulo, SP (Brazil); Francci, C [School of Dentistry, University of Sao Paulo (Brazil); Markarian, R [School of Dentistry, University of Sao Paulo (Brazil); Mori, M [School of Dentistry, University of Sao Paulo (Brazil)

    2006-08-15

    Changes of elementary concentrations in dental enamel after a bleaching treatment with different products, is presented, with special focus on the oxygen contribution. Concentrations for Ca, P, O and C and some other trace elements were obtained for enamel of bovine incisor teeth by HI-ERDA measurements using a {sup 35}Cl incident beam and an ionization chamber. Five groups of teeth with five samples each were treated with a different bleaching agents. Each tooth had its crown sectioned in two halves, one for bleaching test and one the other used as a control. Average values of C/Ca, O/Ca, F/Ca enrichment factors were found. The comparison between bleached and non-bleached halves indicates that bleaching treatment did not affect the mineral structure when low-concentration whitening systems were used. The almost constant oxygen concentration in enamel, suggests little changes due to whitening therapy.

  16. Vertical distribution of trace-element concentrations and occurrence of metallurgical slag particles in accumulated bed sediments of Lake Roosevelt, Washington, September 2002

    Science.gov (United States)

    Cox, S.E.; Bell, P.R.; Lowther, J.S.; Van Metre, P.C.

    2005-01-01

    Sediment cores were collected from six locations in Lake Roosevelt to determine the vertical distributions of trace-element concentrations in the accumulated sediments of Lake Roosevelt. Elevated concentrations of arsenic, cadmium, copper, lead, mercury, and zinc occurred throughout much of the accumulated sediments. Concentrations varied greatly within the sediment core profiles, often covering a range of 5 to 10 fold. Trace-element concentrations typically were largest below the surficial sediments in the lower one-half of each profile, with generally decreasing concentrations from the 1964 horizon to the surface of the core. The trace-element profiles reflect changes in historical discharges of trace elements to the Columbia River by an upstream smelter. All samples analyzed exceeded clean-up guidelines adopted by the Confederated Tribes of the Colville Reservation for cadmium, lead, and zinc and more than 70 percent of the samples exceeded cleanup guidelines for mercury, arsenic, and copper. Although 100 percent of the samples exceeded sediment guidelines for cadmium, lead, and zinc, surficial concentrations of arsenic, copper, and mercury in some cores were less than the sediment-quality guidelines. With the exception of copper, the trace-element profiles of the five cores collected along the pre-reservoir Columbia River channel typically showed trends of decreasing concentrations in sediments deposited after the 1964 time horizon. The decreasing concentrations of trace elements in the upper half of cores from along the pre-reservoir Columbia River showed a pattern of decreasing concentrations similar to reductions in trace-element loading in liquid effluent from an upstream smelter. Except for arsenic, trace-element concentrations typically were smaller at downstream reservoir locations along the pre-reservoir Columbia River. Trace-element concentration in sediments from the Spokane Arm of the reservoir showed distinct differences compared to the similarities

  17. Ultra-trace determination of neptunium-237 and plutonium isotopes in urine samples by compact accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dai, X.; Christl, M.; Kramer-Tremblay, S., E-mail: sheila.kramer-tremblay@cnl.ca [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada); Synal, H-A. [ETH Zurich, Lab. of Ion Beam Physics, Zurich (Switzerland)

    2015-12-15

    Ultra-trace analysis of actinides, such as Pu isotopes and {sup 237}Np, in bioassay samples is often needed for radiation protection programs at nuclear facilities. Accelerator mass spectrometry (AMS), particularly the compact ETH Zurich system “Tandy”, has evolved over the years as one of the most sensitive, selective, and robust techniques for actinide analysis. Employment of the AMS technique can reduce the demands on sample preparation chemistry and increase sample analysis throughput, due to very low instrumental detection limit, high rejection of interferences, and low susceptibility to adverse sample matrices. Initial research and development tests were performed to explore and demonstrate the analytical capability of AMS for Pu and Np urine bioassay. In this study, urine samples spiked with femtogram levels of Np and Pu isotopes were prepared and measured using compact ETH AMS system and the results showed excellent analytical capability for measuring Np and Pu isotopes at femtogram/litre levels in urine. (author)

  18. Trace metal concentrations in marine organisms from the Eastern Aegean, Turkey

    International Nuclear Information System (INIS)

    Kucuksezgin, F.

    1999-01-01

    Monitoring of mercury, cadmium and lead levels in striped mullet (Mullus barbatus) was conducted in the Eastern Aegean over 3 year period and in some other species during 1996 in the framework of a National Marine Measurement Program and MED-POL II Project for the Aegean Sea. Of all the research on the concentrations of trace metals in the Aegean environment only a little has been carried out in that part of the Eastern Aegean

  19. Trace metals in heavy crude oils and tar sand bitumens

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, J.G.

    1990-11-28

    Fe, Ni, and V are considered trace impurities in heavy crude oils and tar sand bitumens. In order to understand the importance of these metals, we have examined several properties: (1) bulk metals levels, (2) distribution in separated fractions, (3) size behavior in feeds and during processing, (4) speciation as a function of size, and (5) correlations with rheological properties. Some of the results of these studies show: (1) V and Ni have roughly bimodal size distributions, (2) groupings were seen based on location, size distribution, and Ni/V ratio of the sample, (3) Fe profiles are distinctively different, having a unimodal distribution with a maximum at relatively large molecular size, (4) Fe concentrations in the tar sand bitumens suggest possible fines solubilization in some cases, (5) SARA separated fractions show possible correlations of metals with asphaltene properties suggesting secondary and tertiary structure interactions, and (6) ICP-MS examination for soluble ultra-trace metal impurities show the possibility of unexpected elements such as U, Th, Mo, and others at concentrations in the ppB to ppM range. 39 refs., 13 figs., 5 tabs.

  20. Trace analysis of Cd, Cu, Pb and Zn in various materials using differential pulse anodic stripping voltammetry

    International Nuclear Information System (INIS)

    Ahmed, R.; Viqar-un-Nisa; Tanwir, R.

    1988-09-01

    Sampling and sample preparation methods have been described. Digestion methods for different types of materials and acid purification systems have been developed. For trace analysis purposes cleaning methods for glassware etc. have been described. Differential pulse anodic stripping voltametric (DPASV) method has been worked out for the trace analysis of zn, cd, pb and Cu in different types of materials. Linearity of the method has been checked by drawing concentration versus currents (peak height) curves. Precision of the method has been checked by analysing a number of actual samples. of the method has been verified by analysing standards of U.S.A. Comparative studies have been done between Differential pulse anodic stripping voltammetric method and Atomic Absorption spectroscopic method. Problems of contamination and systematic errors during trace and ultra-trace analysis have been discussed. A variety of samples including soil, spinach, wheat flour, rice flour, dry milk, coriander, kidney stones, bladder stones etc. have been analysed and preliminary results have been reported. (author)

  1. Concentrations and distributions of trace and minor elements in Chinese and Canadian coals and ashes

    International Nuclear Information System (INIS)

    Sun Jingxin; Jervis, R.E.

    1987-01-01

    A total of 35 trace and minor elements including some of environmental significance were determined in each of a selection of 15 Chinese and 6 Canadian thermal coals and their ashes by using the SLOWPOKE-2 nuclear reactor facility of the University of Toronto. The concentrations and distributions of these constituents among the coals and their combustion products (viz. ash and volatile matter) are presented. The detailed results showed wide variations in trace impurity concentrations (up to a factor of 100 and more) among the coals studied. Values for elemental enrichment factors (EF) relative to normal crustal abundances indicated that only As(EF=13), Br(5.7), I(16), S(230), Sb(11) and Se(320) were appreciably enriched in coal. (author) 14 refs.; 5 tabs

  2. Behaviour study of trace radioelements in the cycles of uranium conversion

    International Nuclear Information System (INIS)

    Bertaux, M.

    1998-01-01

    The aim of this work was to study the presence of ultra-trace radioelements in the cycles of uranium conversion. Radiochemical methods for determining ultra-trace amounts of various elements in uranium have been perfected. These methods are based on the chromatographic separation of anionic complexes and on the measurement of various activities by alpha spectrometry. Thus, the source of these traces has been determined and a work of tracing has been carried out in the Malvesi site (uranium purification unit). This work has revealed an accumulation of these traces in the uranium purification column, consequently to their extraction by the TBP. A decontamination process of weakly contaminated uranium batches has been proposed using the Parex computer model and tested at the industrial scale. This process is based on the U(VI) extraction by the TBP/ISOPAR mixture and on the use of oxalic acid as the complexing agent of the tetravalent actinides in aqueous phase. It has been tested with success during a purification study of a batch of about 4 tons of uranium contaminated by traces of various radioelements. The preliminary study had taken into account the influence of metallic impurities (iron, nickel, copper) on the radioelements complexation by the oxalate ions. (O.M.)

  3. LA-ICP-MS for Trace Analysis of Long-Lived Radionuclides in Solid Non-conducting Radioactive Waste Samples

    International Nuclear Information System (INIS)

    Becker, J.S.; Gastel, M.; Tenzler, D.; Dietze, H.J.

    1999-01-01

    The characterization of radioactive waste materials from nuclear reactors for recycling and final storage requires fast, sensitive and precise analytical methods, which are able to determine long-lived radionuclidic ultra traces in a short time. For the determination of long-lived α and β ray-emitting nuclides besides the classical radiochemical methods which are mostly include time-consuming radiochemical separation procedures, to an increasing extent inductively coupled plasma mass spectrometry (ICP-MS) has been used successfully as a powerful trace, ultra trace and isotopic analytical method for the determination of long-lived radionuclides in aqueous solutions [1-3

  4. Variations in time and space of trace metal aerosol concentrations in urban areas and their surroundings

    Science.gov (United States)

    Moreno, T.; Querol, X.; Alastuey, A.; Reche, C.; Cusack, M.; Amato, F.; Pandolfi, M.; Pey, J.; Richard, A.; Prévôt, A. S. H.; Furger, M.; Gibbons, W.

    2011-09-01

    Using an unprecedentedly large geochemical database, we compare temporal and spatial variations in inhalable trace metal background concentrations in a major city (Barcelona, Spain) and at a nearby mountainous site (Montseny) affected by the urban plume. Both sites are contaminated by technogenic metals, with V, Pb, Cu, Zn, Mn, Sn, Bi, Sb and Cd all showing upper continental crust (UCC) normalised values >1 in broadly increasing order. The highest metal concentrations usually occur during winter at Barcelona and summer in Montseny. This seasonal difference was especially marked at the remote mountain site in several elements such as Ti and Rare Earth Elements, which recorded campaign maxima, exceeding PM10 concentrations seen in Barcelona. The most common metals were Zn, Ti, Cu, Mn, Pb and V. Both V and Ni show highest concentrations in summer, and preferentially fractionate into the finest PM sizes (PM1/PM10 > 0.5) especially in Barcelona, this being attributed to regionally dispersed contamination from fuel oil combustion point sources. Within the city, hourly metal concentrations are controlled either by traffic (rush hour double peak for Cu, Sb, Sn, Ba) or industrial plumes (morning peak of Ni, Mn, Cr generated outside the city overnight), whereas at Montseny metal concentrations rise during the morning to a single, prolonged afternoon peak as contaminated air transported by the sea breeze moves into the mountains. Our exceptional database, which includes hourly measurements of chemical concentrations, demonstrates in more detail than previous studies the spatial and temporal variability of urban pollution by trace metals in a given city. Technogenic metalliferous aerosols are commonly fine in size and therefore potentially bioavailable, emphasising the case for basing urban background PM characterisation not only on physical parameters such as mass but also on sample chemistry and with special emphasis on trace metal content.

  5. Trace Metals Concentration Assessment in Urban Particulate Matter ...

    African Journals Online (AJOL)

    ADOWIE PERE

    Principal component analysis revealed that major sources of trace metals in ambient air ... contributed by earth crust and windblown soil .... Source Apportionment: To probe the origin of trace .... atmospheric accumulation of heavy metals and.

  6. studies on trace metal concentration pseudotolithus elongatus from ...

    African Journals Online (AJOL)

    DJFLEX

    KEY WORDS: Trace metals, Lead Pollution, Pseudotolithus elongatus, Mbo coastal waters, ..... Analysis of soil heavy metal pollution and ... Pekey, H., Karakas, D., and Bakog'lu, M., 2004. Source apportionment of trace metals in the surface.

  7. Sensitive and ultra-fast species detection using pulsed cavity ringdown spectroscopy

    KAUST Repository

    Alquaity, Awad

    2015-01-01

    Pulsed cavity ringdown spectroscopy (CRDS) is used to develop a novel, ultra-fast, high-sensitivity diagnostic for measuring species concentrations in shock tube experiments. The diagnostic is demonstrated by monitoring trace concentrations of ethylene in the mid-IR region near 949.47 cm-1. Each ringdown measurement is completed in less than 1 μs and the time period between successive pulses is 10 μs. The high sensitivity diagnostic has a noise-equivalent detection limit of 1.08 x 10-5 cm-1 which enables detection of 15 ppm ethylene at fuel pyrolysis conditions (1845 K and 2 bar) and 294 ppb ethylene under ambient conditions (297 K and 1 bar). To our knowledge, this is the first successful application of the cavity ringdown method to the measurement of species time-histories in a shock tube. © 2015 OSA.

  8. Preparation of ultra-light magnetic nanocomposites using highly concentrated emulsions

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Goutam; Vilchez, Alejandro; Esquena, Jordi; Solans, Conxita [Instituto de Quimica Avanzada de Cataluna, Consejo Superior de Investigaciones Cientificas (IQAC-CSIC), Jordi Girona 18-26, 08034 Barcelona (Spain); Rodriguez-Abreu, Carlos, E-mail: carlos.rodriguez@inl.int [Instituto de Quimica Avanzada de Cataluna, Consejo Superior de Investigaciones Cientificas (IQAC-CSIC), Jordi Girona 18-26, 08034 Barcelona (Spain); International Iberian Nanotechnology Laboratory (INL), Av. Mestre Jose Veiga, 4715-330 Braga (Portugal)

    2011-10-17

    Highlights: {yields} Polystyrene-divinylbenzene-iron oxide nanocomposites. {yields} Porous magnetic nanocomposites from highly concentrated emulsions. {yields} Ultralight materials with relatively high magnetic moment. - Abstract: Hybrid inorganic-organic ultra-light magnetic solid foams with iron oxide nanoparticles embedded in a divinylbenzene-polystyrene matrix were prepared using a highly concentrated emulsion polymerization method. Iron oxide nanoparticles with diameters of 3 and 10 nm were synthesized using two different methods. For comparison purposes, nanocomposites with magnetite nanoparticles dispersed in a non-porous polymeric matrix obtained by bulk polymerization were also investigated. Materials were characterized using several techniques such as dynamic light scattering (DLS), X-ray diffraction (XRD), thermogravimetric analysis (TGA), small angle X-ray scattering (SAXS), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FTIR) and magnetization measurements. SEM and TEM images showed that solid foams are made of well-defined macro pores with nanoparticles embedded in the walls. The density of the solid foams was ca. 50-70 kg m{sup -3}, which is about 20 times lighter than the non-porous monoliths. The magnetic measurements show that both nanocomposites are superparamagnetic, and that there are differences regarding the interparticle interactions depending on matrix porosity. The synthesized materials may find applications in adsorbents, tissue reparation, enzyme supports, microreactors, or in water decontamination.

  9. Preparation of ultra-light magnetic nanocomposites using highly concentrated emulsions

    International Nuclear Information System (INIS)

    Ghosh, Goutam; Vilchez, Alejandro; Esquena, Jordi; Solans, Conxita; Rodriguez-Abreu, Carlos

    2011-01-01

    Highlights: → Polystyrene-divinylbenzene-iron oxide nanocomposites. → Porous magnetic nanocomposites from highly concentrated emulsions. → Ultralight materials with relatively high magnetic moment. - Abstract: Hybrid inorganic-organic ultra-light magnetic solid foams with iron oxide nanoparticles embedded in a divinylbenzene-polystyrene matrix were prepared using a highly concentrated emulsion polymerization method. Iron oxide nanoparticles with diameters of 3 and 10 nm were synthesized using two different methods. For comparison purposes, nanocomposites with magnetite nanoparticles dispersed in a non-porous polymeric matrix obtained by bulk polymerization were also investigated. Materials were characterized using several techniques such as dynamic light scattering (DLS), X-ray diffraction (XRD), thermogravimetric analysis (TGA), small angle X-ray scattering (SAXS), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FTIR) and magnetization measurements. SEM and TEM images showed that solid foams are made of well-defined macro pores with nanoparticles embedded in the walls. The density of the solid foams was ca. 50-70 kg m -3 , which is about 20 times lighter than the non-porous monoliths. The magnetic measurements show that both nanocomposites are superparamagnetic, and that there are differences regarding the interparticle interactions depending on matrix porosity. The synthesized materials may find applications in adsorbents, tissue reparation, enzyme supports, microreactors, or in water decontamination.

  10. Determination of trace concentration of uranium in soils by the nuclear track technique

    International Nuclear Information System (INIS)

    Islam, G.S.; Abdullah, M.N.A.

    1998-04-01

    Solid state nuclear track detector CR-39 has been used to estimate trace concentration of uranium in soil and sand samples from various places of Bangladesh. Uranium contents in soil samples have been found to vary from ∼3.79 to ∼8.63 ppm and in sand samples from ∼2.39 to ∼6.53 ppm. The mean concentration in soil and in sand samples were found to be ∼4.52 and ∼2.96 ppm respectively. The maximum uranium concentration in soil samples was observed in Sylhet while the uranium concentration of sand was found to be maximum in the sea beach of Cox's Bazar. The implication of results is briefly discussed in the paper. (author)

  11. Selected Trace Element Concentrations in Peat Used for Cosmetic Production – A Case Study from Southern Poland

    Directory of Open Access Journals (Sweden)

    Glina Bartłomiej

    2016-12-01

    Full Text Available The aim of the study was to assess the concentration of selected trace elements in organic soils used as a source to obtain a unique peat extract for cosmetics production. Peat material for laboratory analysis were collected from fen peatland located in the Prosna River Valley (Borek village. Studied peatland is managed by “Torf Corporation” company as a source of material to obtain peat extract for cosmetics production. In the collected soil samples (four soil profiles Zn, Cu and Pb concentrations were determined by using atomic absorption spectrometer SpectraAA 220 (Varian, after acid digestion. Obtained results showed that the highest concentrations of selected trace elements were recorded in the surface horizons of organic soils. This fact might be the results of Prosna river flooding or air deposition. Howevere, according to the new Polish regulations (Ordinance of the Minister for Environment 01.09.2016 - the way of conducting contamination assessment of the earth surface, the content of trace elements in the examined soils was greatly belowe the permissible limit for areas from group IV (mine lands. Thus, described soils are proper to obtain peat extract used as a component in cosmetic production.

  12. A Sub-band Divided Ray Tracing Algorithm Using the DPS Subspace in UWB Indoor Scenarios

    DEFF Research Database (Denmark)

    Gan, Mingming; Xu, Zhinan; Hofer, Markus

    2015-01-01

    Sub-band divided ray tracing (SDRT) is one technique that has been extensively used to obtain the channel characteristics for ultra-wideband (UWB) radio wave propagation in realistic indoor environments. However, the computational complexity of SDRT scales directly with the number of sub-bands. A......Sub-band divided ray tracing (SDRT) is one technique that has been extensively used to obtain the channel characteristics for ultra-wideband (UWB) radio wave propagation in realistic indoor environments. However, the computational complexity of SDRT scales directly with the number of sub...

  13. InPhoCUS (Inflated Photovoltaic Ultra-light Mirror Concentrators): First Results Of The Project And Future Perspectives

    Science.gov (United States)

    Pravettoni, Mauro; Barbato, Maurizio; Cooper, Thomas; Pedretti, Andrea; Ambrosetti, Gianluca; Steinfeld, Aldo

    2011-12-01

    InPhoCUS (Inflated PhotovoltaiC Ultra-light mirror concentratorS) is a concentrating photovoltaic (CPV) project funded by the Swiss Confederation's Innovation Promotion Agency (CTI) and developed by Airlight Energy Holding SA, the University of Applied Sciences and Arts of Southern Switzerland and the Swiss Federal Institute of Technology. The proposed novel concentrating system has already been patented for concentrated solar power applications: it is made by unconventional pneumatic multilayer polymeric mirrors, has an innovative fibre-reinforced concrete structure and an original tilting mechanism to track the sun. The innovative CPV solar collector is profitable for electric power plants both for the sun-belt region and in the Mediterranean. In this paper the authors present the novel CPV system and preliminary results on cost analysis, optical design and thermal modelling.

  14. Derivative flame atomic absorption spectrometry and its application in trace analysis

    International Nuclear Information System (INIS)

    Sun, H. W.; Li, L. Q.

    2005-01-01

    Flame atomic absorption spectrometry is an accepted and widely used method for the determination of trace elements in a great variety of samples. But its sensitivity doesn't meet the demands of trace and ultra-trace analysis for some samples. The derivative signal processing technique, with a very high capability for enhancing sensitivity, was developed for flame atomic absorption spectrometry. The signal models of conventional flame atomic absorption spectrometry are described. The equations of derivative signals are established for flame atomic absorption spectrometry, flow injection atomic absorption spectrometry (FI-FAAS) and atom trapping flame atomic absorption spectrometry (AT-FAAS). The principle and performance of the derivative atomic absorption spectrometry are evaluated. The derivative technique based on determination of variation rate of signal intensity with time (dl/dt) is different from the derivative spectrophotometry based on determination of variation rate of signal intensity with wavelength (dl/dhλ). Derivative flame atomic absorption spectrometry has higher sensitivity, lower detection limits and better accuracy. It has been applied to the direct determination of trace elements without preconcentration. If the derivative technique was combined with several preconcentration techniques, the sensitivity would be enhanced further for ultra-trace analysis with good linearity. The applications of derivative flame atomic absorption spectroscopy are reviewed for trace element analysis in biological, pharmaceutical, environmental and food samples

  15. Detection of ultra-low oxygen concentration based on the fluorescence blinking dynamics of single molecules

    Science.gov (United States)

    Wu, Ruixiang; Chen, Ruiyun; Zhou, Haitao; Qin, Yaqiang; Zhang, Guofeng; Qin, Chengbing; Gao, Yan; Gao, Yajun; Xiao, Liantuan; Jia, Suotang

    2018-01-01

    We present a sensitive method for detection of ultra-low oxygen concentrations based on the fluorescence blinking dynamics of single molecules. The relationship between the oxygen concentration and the fraction of time spent in the off-state, stemming from the population and depopulation of triplet states and radical cationic states, can be fitted with a two-site quenching model in the Stern-Volmer plot. The oxygen sensitivity is up to 43.42 kPa-1 in the oxygen partial pressure region as low as 0.01-0.25 kPa, which is seven times higher than that of the fluorescence intensity indicator. This method avoids the limitation of the sharp and non-ignorable fluctuations that occur during the measurement of fluorescence intensity, providing potential applications in the field of low oxygen-concentration monitoring in life science and industry.

  16. Using ultra-osmosis to concentrate residues upto 20% solids using 10% of the energy of conventional methods

    Energy Technology Data Exchange (ETDEWEB)

    O' Shea, J A

    1990-01-01

    In the Food Industry, generally that is, Milk, Beet, Grain and Potato processing the major energy input is the removal of water from the raw material. This is particularly important in the milk Industry where liquid milk has a water content of 88%. When the fat and protein are removed it is only 6% solid or 94% water. The consideration of Ultra-Osmosis is beneficial in its energy efficiency compared to thermal vapour recompression and also has the side benefit as being a demineralisation plant as well. Reverse Osmosis is a unique cross lined polyamide membrane. Its rejection characteristics enable it to discriminate among low molecular weight species. The pore structure of the membrane is such that a separation between sodium chloride and calcium sulphate may be accomplished. Such separations are useful in a variety of applications. The utility of the membrane is further enhanced by the simultaneous ability to concentrate the retained species. The Ultra Osmosis process based on a membrane with rejection characteristics intermediate between those common in Ultra Filtration and Reverse Osmosis opens the road to a whole new spectrum of membrane separations. 3 figs.

  17. COMPARISON OF DIFFERENT EXTRACTION METHODS REPRESENTING AVAILABLE AND TOTAL CONCENTRATIONS OF Cd, Cu, Fe, Mn and Zn IN SOIL

    Directory of Open Access Journals (Sweden)

    Vladimir Ivezić

    2013-06-01

    Full Text Available Various extraction methods are used to predict plant uptake of trace metals. Most commonly it is total concentration that is used for risk assessment and evaluation of trace metal availability. However, recent studies showed that total concentration is a poor indicator of availability while concentrations in soil solution show good correlation with plant uptake. Present study was conducted on magricultural soils with low levels of trace metals where 45 soil samples were collected from different soil types. The main objective was to compare four different extraction methods and examine how total and reactive (EDTA trace metal concentrations correlate ,with soil solution concentration (in this study determined by water extraction. The samples were analyzed by four extraction methods: strong acid extraction (ultra-pure HNO3 extraction and aqua regia, weak acid extraction by EDTA and the most available fraction, fraction in soil solution, were represented by water extraction (weakest extractant. Five elements were investigated (Cd, Cu, Fe, Mn and Zn. Water extraction significantly correlated with EDTA extraction for Cu, Fe and Mn, while total extraction (HNO3 extraction and aqua regia correlated significantly with water extraction only for Cu. No correlation between water extraction and total extraction confirmed poor role of total concentration as an indicator of availability. EDTA extraction can be used to represent reactive pool of trace metals in soil but it should be also taken with caution when using it to describe available fraction.

  18. Trace elements in the sea surface microlayer: rapid responses to changes in aerosol deposition

    Directory of Open Access Journals (Sweden)

    Alina M. Ebling

    2017-08-01

    Full Text Available Natural and anthropogenic aerosols are a significant source of trace elements to oligotrophic ocean surface waters, where they provide episodic pulses of limiting micronutrients for the microbial community. However, little is known about the fate of trace elements at the air-sea interface, i.e. the sea surface microlayer. In this study, samples of aerosols, sea surface microlayer, and underlying water column were collected in the Florida Keys during a dusty season (July 2014 and non-dusty season (May 2015 and analyzed for the dissolved and particulate elements Al, Fe, Ni, Cu, Zn, and Pb. Microlayer samples were collected using a cylinder of ultra-pure SiO2 (quartz glass, a novel adaptation of the glass plate technique. A significant dust deposition event occurred during the 2014 sampling period which resulted in elevated concentrations of trace elements in the microlayer. Residence times in the microlayer from this event ranged from 12 to 94 minutes for dissolved trace elements and from 1.3 to 3.4 minutes for particulate trace elements. These residence times are potentially long enough for the atmospherically derived trace elements to undergo chemical and biological alterations within the microlayer. Characterizing the trace element distributions within the three regimes is an important step towards our overall goals of understanding the rates and mechanisms of the solubilization of trace elements following aeolian dust deposition and how this might affect microorganisms in surface waters.

  19. Concentrations of 23 trace elements in ground water and surface water at and near the Idaho National Engineering Laboratory, Idaho, 1988--91

    International Nuclear Information System (INIS)

    Liszewski, M.J.; Mann, L.J.

    1993-01-01

    Analytical data for 23 trace elements are reported for ground- and surface-water samples collected at and near the Idaho National Engineering Laboratory during 1988--91. Water samples were collected from 148 wells completed in the Snake River Plain aquifer, 18 wells completed in discontinuous deep perched-water zones, and 1 well completed in an alluvial aquifer. Surface-water samples also were collected from three streams, two springs, two ponds, and one lake. Data are categorized by concentrations of total recoverable of dissolved trace elements. Concentrations of total recoverable trace elements are reported for unfiltered water samples and include results for one or more of the following: aluminum, arsenic, barium, beryllium, cadmium, chromium, cobalt, copper, iron, lead, manganese, mercury, nickel, selenium, silver, and zinc. Concentrations of dissolved trace elements are reported for water samples filtered through a nominal 0.45-micron filter and may also include bromide, fluoride, lithium, molybdenum, strontium, thallium, and vanadium. Concentrations of dissolved hexavalent chromium also are reported for many samples. The water samples were analyzed at the US Geological Survey's National Water Quality Laboratory in Arvada, Colorado. Methods used to collect the water samples and quality assurance instituted for the sampling program are described. Concentrations of chromium equaled or exceeded the maximum contaminant level at 12 ground-water quality monitoring wells. Other trace elements did not exceed their respective maximum contaminant levels

  20. Concentrations of 23 trace elements in ground water and surface water at and near the Idaho National Engineering Laboratory, Idaho, 1988--91

    Energy Technology Data Exchange (ETDEWEB)

    Liszewski, M.J.; Mann, L.J.

    1993-12-31

    Analytical data for 23 trace elements are reported for ground- and surface-water samples collected at and near the Idaho National Engineering Laboratory during 1988--91. Water samples were collected from 148 wells completed in the Snake River Plain aquifer, 18 wells completed in discontinuous deep perched-water zones, and 1 well completed in an alluvial aquifer. Surface-water samples also were collected from three streams, two springs, two ponds, and one lake. Data are categorized by concentrations of total recoverable of dissolved trace elements. Concentrations of total recoverable trace elements are reported for unfiltered water samples and include results for one or more of the following: aluminum, arsenic, barium, beryllium, cadmium, chromium, cobalt, copper, iron, lead, manganese, mercury, nickel, selenium, silver, and zinc. Concentrations of dissolved trace elements are reported for water samples filtered through a nominal 0.45-micron filter and may also include bromide, fluoride, lithium, molybdenum, strontium, thallium, and vanadium. Concentrations of dissolved hexavalent chromium also are reported for many samples. The water samples were analyzed at the US Geological Survey`s National Water Quality Laboratory in Arvada, Colorado. Methods used to collect the water samples and quality assurance instituted for the sampling program are described. Concentrations of chromium equaled or exceeded the maximum contaminant level at 12 ground-water quality monitoring wells. Other trace elements did not exceed their respective maximum contaminant levels.

  1. A SIMS study of lunar 'komatiitic glasses' - Trace element characteristics and possible origin

    Science.gov (United States)

    Shearer, C. K.; Papike, J. J.; Galbreath, K. C.; Wentworth, S. J.; Shimizu, N.

    1990-01-01

    In Apollo 16 regolith breccias, Wentworth and McKay (1988) identified a suite of minute (less than 120 microns) 'komatiitic glass beads'. The wide major element compositional range, and ultra-Mg-prime character of the glasses suggest a variety of possible origins from complex impact processes to complex volcanic processes involving rather unusual and primitive magmatism. The extent of trace element depletion or enrichment in these glasses appears to be correlated to the siderophile character of the element (ionization potential or experimentally determined silicate melt/Fe metal partition coefficients. The ultra-Mg-prime glasses are depleted in Co relative to a bulk Moon Mg/Co exhibited by many lunar samples (volcanic glasses, basalts, regolith breccia, estimated upper mantle). The low Co and high incompatible element concentrations diminish the possibility that these glasses are a product of lunar komatiitic volcanism or impact, excavation, and melting of a very high Mg-prime plutonic unit.

  2. The major and trace element chemistry of fish and lake water within ...

    African Journals Online (AJOL)

    2016-01-01

    Jan 1, 2016 ... and Abanoz (2011), De La Calle et al. (2012) and Sannac et al. (2012) of the same reference material. Dilution factors were cho- sen to include both major and trace elements in the same analy- ses, which implies that the method was not sensitive enough to analyse some elements at ultra-trace levels.

  3. Serum concentrations of trace elements in patients with Crohn's disease receiving enteral nutrition.

    Science.gov (United States)

    Johtatsu, Tomoko; Andoh, Akira; Kurihara, Mika; Iwakawa, Hiromi; Tsujikawa, Tomoyuki; Kashiwagi, Atsunori; Fujiyama, Yoshihide; Sasaki, Masaya

    2007-11-01

    We investigated the trace element status in Crohn's disease (CD) patients receiving enteral nutrition, and evaluated the effects of trace element-rich supplementation. Thirty-one patients with CD were enrolled in this study. All patients were placed on an enteral nutrition regimen with Elental(R) (Ajinomoto pharmaceutical. Ltd., Tokyo, Japan). Serum selenium, zinc and copper concentrations were determined by atomic absorption spectroscopy. Serum selenoprotein P levels were determined by an ELISA system. Average serum levels of albumin, selenium, zinc and copper were 4.1 +/- 0.4 g/dl, 11.2 +/- 2.8 microg/dl, 71.0 +/- 14.8 microg/dl, and 112.0 +/- 25.6 microg/dl, respectively. In 9 patients of 31 CD patients, serum albumin levels were lower than the lower limit of the normal range. Serum selenium, zinc and copper levels were lower than lower limits in 12 patients, 9 patients and 1 patient, respectively. Serum selenium levels significantly correlated with both serum selenoprotein P levels and glutathione peroxidase activity. Supplementation of selenium (100 microg/day) and zinc (10 mg/day) for 2 months significantly improved the trace element status in CD patients. In conclusion, serum selenium and zinc levels are lower in many CD patients on long-term enteral nutrition. In these patients, supplementation of selenium and zinc was effective in improving the trace element status.

  4. Trace element concentrations in the fruit peels and trunks of Musa paradisiaca.

    Science.gov (United States)

    Selema, M D; Farago, M E

    1996-08-01

    Chemical analyses for the elementary compositions of the ashes of the fruit peels and trunks of the tropical plantain Musa paradisiaca have been undertaken. The elements, categorized as trace elements, generally are found to have higher mean concentrations in the fruit peels than in the trunks (except in the case of Zn). Their peel-trunk uptake ratios have been calculated and range between 1 and 4, showing normal levels of accumulations in the fruit peels over the trunks.

  5. Trace element concentration in head hair of the inhabitans of the Rawalpindi-Islamabad area

    International Nuclear Information System (INIS)

    Qureshi, I.H.; Chaudhary, M.S.; Ahmad, S.

    1982-01-01

    Instrumental neutron activation analysis technique has been used to determine the concentration levels of 12 trace elements in human head hair samples collected from 105 individuals living in various areas of Rawalpindi-Islamabad. The data show that the average concentrations of Mn, Co, Ag and Au are higher in the female group as compared to the male group. Four individuals were found to have elevated levels of Se due to the use of anti-dandruff shampoos, whereas two individuals had elevated levels of Hg. (author)

  6. Neutron activation analysis for bulk and trace elements in urine

    International Nuclear Information System (INIS)

    Cornelis, R.; Speecke, A.; Hoste, J.

    1975-01-01

    Problems in sampling urine for trace element analysis by neutron activation are systematically examined. Collection, storage, sample preparation and contamination hazards during irradiation are studied in detail. Three different sizes of urine samples are prepared for analysis, depending on the concentration and nuclear properties of the elements, and suitable multielement doped urine standards are used. As, Br, Ca, Cl, Co, Cr, Cs, Cu, Hg, I, K, Mg, Mn, Na, Rb, Se and Zn are determined. The extreme care given to sample collection, use of ''ultra-clean'' vials, and work in a dust-free room allows consistent values to be obtained over long periods of time. A literature review of the amounts of forty elements present in urine per day is also given

  7. Trace mercury determination in drinking and natural water after preconcentration and separation by DLLME-SFO method coupled with cold vapor atomic absorption spectrometry

    OpenAIRE

    Abdollahi Atousa; Amirkavehei Mooud; Gheisari Mohammad Mehdi; Tadayon Fariba

    2014-01-01

    A novel dispersive liquid–liquid microextraction based on solidification of floating organic drop (DLLME-SFO) for simultaneous separation/preconcentration of ultra trace amounts of mercury was used. A method based on amalgamation was used for collection of gaseous mercury on gold coated sand (Gold trap). The concentration of mercury was determined by cold vapor atomic absorption spectrometry (CV-AAS). The DLLME-SFO behavior of mercury by using dithizone as complexing agent was systematically ...

  8. Atmospheric CO{sub 2}, trace gas and CN concentrations in Vaerrioe

    Energy Technology Data Exchange (ETDEWEB)

    Ahonen, T; Aalto, P; Kulmala, M; Rannik, U; Vesala, T [Helsinki Univ. (Finland). Dept. of Physics; Hari, P; Pohja, T [Helsinki Univ. (Finland). Dept. of Forest Ecology

    1996-12-31

    The Vaerrioe environmental measurement station is founded in 1991. The aim of the station is to obtain more information on air quality influenced by Kola industrial areas and effects of pollutants on photosynthesis in subarctic climate. In the station air quality and meteorological quantities are measured together with photosynthesis, which makes it quite unique in comparison with other measurement stations located in northern Finland. The measurements also provide information of aerosol and trace gas concentrations in order to study the direct and indirect aerosol effects on climate. These measurements also increase the knowledge of atmospheric chemistry and deposition in subarctic conditions

  9. Atmospheric CO{sub 2}, trace gas and CN concentrations in Vaerrioe

    Energy Technology Data Exchange (ETDEWEB)

    Ahonen, T.; Aalto, P.; Kulmala, M.; Rannik, U.; Vesala, T. [Helsinki Univ. (Finland). Dept. of Physics; Hari, P.; Pohja, T. [Helsinki Univ. (Finland). Dept. of Forest Ecology

    1995-12-31

    The Vaerrioe environmental measurement station is founded in 1991. The aim of the station is to obtain more information on air quality influenced by Kola industrial areas and effects of pollutants on photosynthesis in subarctic climate. In the station air quality and meteorological quantities are measured together with photosynthesis, which makes it quite unique in comparison with other measurement stations located in northern Finland. The measurements also provide information of aerosol and trace gas concentrations in order to study the direct and indirect aerosol effects on climate. These measurements also increase the knowledge of atmospheric chemistry and deposition in subarctic conditions

  10. Application of trace element analysis to determine trace element concentrations in the field of medicine

    International Nuclear Information System (INIS)

    Kasperek, K.; Feinendegen, L.E.

    1976-01-01

    Applied trace elements research in medicine requires a sensitive and efficient technique of trace elements analysis such as, e.g., neutron activation analysis. Essential trace elements act as stabilisators (iron in haem), structural elements (silicium in fibrous tissue), in hormones (iodine in thyroid hormone), in vitamins (cobalt in vitamin B 12), and in enzymes. Most of the essential trace elements act as coenzymes or in coenzymes or directly as metabolic catalysators. For example, selenium deficiency in PKU and maple syrup patients receiving dietary treatment can be detected by determining the selenium content of the serum, while low selenium values in the whole blood indicate liver cirrhosis. Acrodermatitis enteropathica can be diagnosed by determinig zinc in the serum, and pancreatic insufficiency by determining zinc in the pancreatic juice. Zinc also plays a part in disturbances of growth, in the healing of wounds, and in the insulin metabolism. Cobalt is important in some types of anaemia and in myocardiopathies. Trace elements are also necessary in the treatment of diseases, e.g. iron cobalt in some types of anaemia, and zinc in the delayed healing of wounds in the postoperative phase and in acrodermatitis enteropathica. Chromium is now being tested for the treatment of diabetes mellitus, and fluorides may be of interest in the treatment of osteoporosis. Finally, trace elements are important in the aetiology of acute poisoning, in nutrition, and in environmental protection. (orig./AK) [de

  11. Effect of zinc from zinc sulfate on trace mineral concentrations of milk in Varamini ewes

    NARCIS (Netherlands)

    Zali, A.; Ganjkhanlou, M.

    2009-01-01

    This study was conducted to evaluate the effect of feeding supplemental zinc (zinc sulfate) in different levels (15, 30, or 45 mg/kg) on trace mineral concentrations in milk of ewes. Thirty lactating Varaminni ewes were assigned to three experimental groups according to their live body weights, milk

  12. A new hybrid algorithm using thermodynamic and backward ray-tracing approaches for modeling luminescent solar concentrators

    Energy Technology Data Exchange (ETDEWEB)

    Lo, Ch. K.; Lim, Y. S.; Tan, S. G.; Rahman, F. A. [Faculty of Engineering and Science, University Tunku Abdul Rahman, Jalan Genting Klang, 53300, Kuala Lumpur (Malaysia)

    2010-12-15

    A Luminescent Solar Concentrator (LSC) is a transparent plate containing luminescent material with photovoltaic (PV) cells attached to its edges. Sunlight entering the plate is absorbed by the luminescent material, which in turn emits light. The emitted light propagates through the plate and arrives at the PV cells through total internal reflection. The ratio of the area of the relatively cheap polymer plate to that of the expensive PV cells is increased, and the cost per unit of solar electricity can be reduced by 75%. To improve the emission performance of LSCs, simulation modeling of LSCs becomes essential. Ray-tracing modeling is a popular approach for simulating LSCs due to its great ability of modeling various LSC structures under direct and diffuse sunlight. However, this approach requires substantial amount of measurement input data. Also, the simulation time is enormous because it is a forward-ray tracing method that traces all the rays propagating from the light source to the concentrator. On the other hand, the thermodynamic approach requires substantially less input parameters and simulation time, but it can only be used to model simple LSC designs with direct sunlight. Therefore, a new hybrid model was developed to perform various simulation studies effectively without facing the issues arisen from the existing ray-tracing and thermodynamic models. The simulation results show that at least 60% of the total output irradiance of a LSC is contributed by the light trapped and channeled by the LSC. The novelty of this hybrid model is the concept of integrating the thermodynamic model with a well-developed Radiance ray-tracing model, hence making this model as a fast, powerful and cost-effective tool for the design of LSCs. (authors)

  13. First assessment of trace metal concentration in mangrove crab eggs and other tissues, SE Brazil.

    Science.gov (United States)

    de Almeida, Eduardo Vianna; Kütter, Vinicius Tavares; Marques, Eduardo Duarte; da Silva-Filho, Emmanoel Vieira

    2016-07-01

    The mangrove crab Ucides cordatus is widespread in the Brazilian coast, which has an important role in nutrient cycling. This species reproduces in summer and females carry eggs about a month, when they maintain contact with water and sediments. It remains unclear if trace metals can be absorbed or adsorbed by the eggs during development. The present study aims to investigate, for the first time, trace metal concentrations in ovigerous female tissues and eggs of U. cordatus in two areas with different metal pollution levels in the Southeastern Brazil. Samples were collected in two different mangroves, Guanabara Bay (GB) highly polluted environment and Paraíba do Sul River (PSR). In both populations, we observed significant increase of V, Cr, and Mn concentrations along eggs maturation. The higher metals averages were found in PSR population. This trend was reported since the 1990s and lower concentrations in GB marine organisms were attributed to reducing conditions, high organic load, and the presence of sulfide ions. These conditions restrict the bioavailability of metals in the bay, with exception of Mn. No significant differences were observed in gills and muscles. In both populations of the present study, V, Zn, As, and Pb were higher in eggs of initial stage, whereas Mn, Ni, Cu, and Cd were higher in hepatopancreas. Beside this, V, Cr, Mn, As, and Pb showed an increase concerning egg development. Thus, V, As, and Pb in eggs come from two sources previous discussed: females and environment. Zinc came mainly from females due to essential function. Those new information should be considered as one of the mechanisms of trace metal transfer to the trophic chain, between benthonic and pelagic environment.

  14. Trace metal concentration in Great Tit (Parus major) and Greenfinch (Carduelis sinica) at the Western Mountains of Beijing, China

    International Nuclear Information System (INIS)

    Deng Haili; Zhang Zhengwang; Chang Chongyan; Wang Yong

    2007-01-01

    We examined the concentrations of 11 trace metals in tissues from 10 body parts of Great Tits and Greenfinches collected at Badachu Park in the Western Mountains of Beijing, China to assess the metal accumulation level, distribution among body parts, and species and gender related variations. The highest concentrations of Hg, Ni, Zn, and Mn were found in the feather; Pb and Co in the bone; Cd, Cr, and Se in the kidney, and Cu in the liver and heart. Metal concentrations had substantial interspecific variation with Great Tits showing higher levels of Hg, Cr, Ni, and Mn than Greenfinches in tissues of most body parts. Gender related variations were body part and species specific. Meta-analyses using data from this study and other studies suggested that metal concentrations of Great Tits at our study site were relatively low and below the toxic levels. - Trace metal concentrations of Great Tits and Greenfinches from Beijing, China, varied by body part, gender, and species, and were below toxic levels

  15. Multi-actinide analysis with AMS for ultra-trace determination and small sample sizes: advantages and drawbacks

    Energy Technology Data Exchange (ETDEWEB)

    Quinto, Francesca; Lagos, Markus; Plaschke, Markus; Schaefer, Thorsten; Geckeis, Horst [Institute for Nuclear Waste Disposal, Karlsruhe Institute of Technology (Germany); Steier, Peter; Golser, Robin [VERA Laboratory, Faculty of Physics, University of Vienna (Austria)

    2016-07-01

    With the abundance sensitivities of AMS for U-236, Np-237 and Pu-239 relative to U-238 at levels lower than 1E-15, a simultaneous determination of several actinides without previous chemical separation from each other is possible. The actinides are extracted from the matrix elements via an iron hydroxide co-precipitation and the nuclides sequentially measured from the same sputter target. This simplified method allows for the use of non-isotopic tracers and consequently the determination of Np-237 and Am-243 for which isotopic tracers with the degree of purity required by ultra-trace mass-spectrometric analysis are not available. With detection limits of circa 1E+4 atoms in a sample, 1E+8 atoms are determined with circa 1 % relative uncertainty due to counting statistics. This allows for an unprecedented reduction of the sample size down to 100 ml of natural water. However, the use of non-isotopic tracers introduces a dominating uncertainty of up to 30 % related to the reproducibility of the results. The advantages and drawbacks of the novel method will be presented with the aid of recent results from the CFM Project at the Grimsel Test Site and from the investigation of global fallout in environmental samples.

  16. Establishment of a clean laboratory for ultra trace analysis of nuclear materials in safeguards environmental samples

    International Nuclear Information System (INIS)

    Hanzawa, Yukiko; Magara, Masaaki; Watanabe, Kazuo

    2003-01-01

    The Japan Atomic Energy Research Institute has established a cleanroom facility with cleanliness of ISO Class 5: the Clean Laboratory for Environmental Analysis and Research (CLEAR). It was designed to be used for the analysis of nuclear materials in environmental samples mainly for the safeguards, in addition to the Comprehensive Nuclear-Test-Ban Treaty verification and research on environmental sciences. The CLEAR facility was designed to meet conflicting requirements of a cleanroom and for handling of nuclear materials according to Japanese regulations, i.e., to avoid contamination from outside and to contain nuclear materials inside the facility. This facility has been intended to be used for wet chemical treatment, instrumental analysis and particle handling. A fume-hood to provide a clean work surface for handling of nuclear materials was specially designed. Much attention was paid to the selection of construction materials for use to corrosive acids. The performance of the cleanroom and analytical background in the laboratory are discussed. This facility has satisfactory specification required for joining the International Atomic Energy Agency Network of Analytical Laboratories. It can be concluded that the CLEAR facility enables analysis of ultra trace amounts of nuclear materials at sub-pictogram level in environmental samples. (author)

  17. Biological processes for concentrating trace elements from uranium mine waters. Technical completion report

    International Nuclear Information System (INIS)

    Brierley, C.L.; Brierley, J.A.

    1981-12-01

    Waste water from uranium mines in the Ambrosia Lake district near Grants, New Mexico, USA, contains uranium, selenium, radium and molybdenum. The Kerr-McGee Corporation has a novel treatment process for waters from two mines to reduce the concentrations of the trace contaminants. Particulates are settled by ponding, and the waters are passed through an ion exchange resin to remove uranium; barium chloride is added to precipitate sulfate and radium from the mine waters. The mine waters are subsequently passed through three consecutive algae ponds prior to discharge. Water, sediment and biological samples were collected over a 4-year period and analyzed to assess the role of biological agents in removal of inorganic trace contaminants from the mine waters. Some of the conclusions derived from this study are: (1) The concentrations of soluble uranium, selenium and molybdenum were not diminished in the mine waters by passage through the series of impoundments which constituted the mine water treatment facility. Uranium concentrations were reduced but this was due to passage of the water through an ion exchange column. (2) The particulate concentrations of the mine water were reduced at least ten-fold by passage of the waters through the impoundments. (3) The sediments were anoxic and enriched in uranium, molybdenum and selenium. The deposition of particulates and the formation of insoluble compounds were proposed as mechanisms for sediment enrichment. (4) The predominant algae of the treatment ponds were the filamentous Spirogyra and Oscillatoria, and the benthic alga, Chara. (5) Adsorptive processes resulted in the accumulation of metals in the algae cells. (6) Stimulation of sulfate reduction by the bacteria resulted in retention of molybdenum, selenium, and uranium in sediments. 1 figure, 16 tables

  18. Assessment of trace element concentration distribution in human placenta by wavelength dispersive X-ray fluorescence: Effect of neonate weight and maternal age

    International Nuclear Information System (INIS)

    Ozdemir, Yueksel; Boerekci, Buenyamin; Levet, Aytac; Kurudirek, Murat

    2009-01-01

    Trace element status in human placenta is dependent on maternal-neonatal characteristics. This work was undertaken to investigate the correlation between essential trace element concentrations in the placenta and maternal-neonatal characteristics. Placenta samples were collected from total 61 healthy mothers at gestation between 37 and 41 weeks. These samples were investigated with the restriction that the mother's age was 20-40 years old and the neonate's weight was 1-4 kg. Percent concentrations of trace elements were determined using wavelength dispersive X-ray fluorescence (WDXRF). The placenta samples were prepared and analyzed without exposure to any chemical treatment. Concentrations of Fe, Cu and Zn in placenta tissues were found statistically to vary corresponding to the age of the mother and weight of the neonate. In the subjects, the concentration of Fe and Cu were increased in heavier neonates (p<0.05) and the concentration of Zn was increased with increasing mother age (p<0.05). Consequently, the Fe, Cu and Zn elements appear to have interactive connections in human placenta.

  19. Factors affecting neutron measurements and calculations. Part C. Trace element concentrations in granite and their impact on thermal neutron activation

    International Nuclear Information System (INIS)

    Ruehm, Werner; Huber, Thomas; Nolte, Eckehart; Kato, Kazuo; Imanaka, Tetsuji; Egbert, Stephen D.

    2005-01-01

    Trace elements such as Li, B, Sm, and Gd can, despite their low elemental concentration in mineral materials, influence thermal neutron activation in Hiroshima and Nagasaki samples, due to their high thermal neutron absorption cross sections. This was demonstrated for a granite core, where the addition of those trace elements to the elemental composition of granite reduces the production of 152 Eu by some 25% at a depth of 25 cm from the surface. If typical concentrations of those trace elements are added to DS02 reference soil, however, the production of 152 Eu one meter above ground is not changed significantly, because of the high water content of the soil. This indicates that DS02 soil represents a reasonable reference material for the air-over-ground transport calculations. It must be kept in mind, however, that the local environment of any sample investigated for thermal neutron activation might be characterized by other elemental compositions. In particular, trace element and hydrogen concentrations could be considerably different from those used for DS02 reference soil. As an example it was demonstrated that in a granite gravestone thermal neutron activation of 36 Cl close to the surface might be, in the worst case, reduced by some 30%, due to increased local granite concentration in this type of environment. Beside other parameters such as, for example, individual sample geometry, the variability of trace elements in soil might be one reason for the variability that is observed in the individual thermal neutron activation measurements (Gold 1995). It is necessary, therefore, to carefully model the exposure geometry of the exposed material, its chemical composition, and the surrounding interface materials in order to obtain the best possible agreement in comparisons between calculated and measured data for thermal neutrons. (author)

  20. Determination of the free ion concentration of trace metals in soil solution using a soil column Donnan membrane technique

    NARCIS (Netherlands)

    Weng, L.; Temminghoff, E.J.M.; Riemsdijk, van W.H.

    2001-01-01

    Accurate measurement of the free metal ion is difficult, especially for trace metals present in very small concentrations (less than micromolar) in natural systems. The recently developed Donnan membrane technique can measure the concentrations in solution in the presence of inorganic and organic

  1. Selective Flow-Injection Quantification of Ultra-trace Amounts of Cr(VI) via On-line Complexation and Preconcentration with APDC Followed by Determination by Electrothermal Atomic Absorption Spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Hansen, Elo Harald

    1998-01-01

    A rapid, sensitive and selective time-based flow injection (FI) preconcentration procedure is described for the determination of ultra-trace amounts of Cr(VI) via on-line reaction with ammonium pyrrolidine dithiocarbamate (APDC) and formation of the Cr(VI)-PDC complex. The preconcentration...... to direct introduction of 55 mu l samples, yielding a detection limit (3 sigma) of 4.2 ng l(-1). The sample frequency was 21.2 samples per hour. The proposed method was evaluated by analyzing drinking water, a NIST Cr(VI)-reference material and synthetic sea water. A major contribution to successful...

  2. In-situ pre-concentration through repeated sampling and pyrolysis for ultrasensitive determination of thallium in drinking water by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Liu, Liwei; Zheng, Huaili; Xu, Bincheng; Xiao, Lang; Chigan, Yong; Zhangluo, Yilan

    2018-03-01

    In this paper, a procedure for in-situ pre-concentration in graphite furnace by repeated sampling and pyrolysis is proposed for the determination of ultra-trace thallium in drinking water by graphite furnace atomic absorption spectrometry (GF-AAS). Without any other laborious enrichment processes that routinely result in analyte loss and contamination, thallium was directly concentrated in the graphite furnace automatically and subsequently subject to analysis. The effects of several key factors, such as the temperature for pyrolysis and atomization, the chemical modifier, and the repeated sampling times were investigated. Under the optimized conditions, a limit of detection of 0.01µgL -1 was obtained, which fulfilled thallium determination in drinking water by GB 5749-2006 regulated by China. Successful analysis of thallium in certified water samples and drinking water samples was demonstrated, with analytical results in good agreement with the certified values and those by inductively coupled plasma mass spectrometry (ICP-MS), respectively. Routine spike-recovery tests with randomly selected drinking water samples showed satisfactory results of 80-96%. The proposed method is simple and sensitive for screening of ultra-trace thallium in drinking water samples. Copyright © 2017. Published by Elsevier B.V.

  3. Collection/concentration of trace uranium for spectrophotometric detection using activated carbon and first-derivative spectrophotometry

    International Nuclear Information System (INIS)

    El-Sayed, A.A.; Hamed, M.M.; El-Reefy, S.; Hmmad, H.A.

    2007-01-01

    The need exists for preconcentration of trace and ultratrace amounts of uranium from environmental, geological and biological samples. The adsorption of uranium on various solids is important from the purification, environmental, and radioactivity waste disposal points of view. A method is described for the determination of traces of uranium using first-derivative spectrophotometry after adsorptive preconcentration of uranium on activated carbon. Various parameters that influence the adsorptive preconcentration of uranium on activated carbon, viz., pH, amounts of activated carbon and time of stirring and interference of metals have been studied. First-derivative spectrophotometry in conjunction with adsorptive preconcentration of uranium on activated carbon is used for determining uranium at concentration levels down to 20 ppb (w/v). (orig.)

  4. Application of trace element analysis to determine trace element concentrations in the field of medicine. [Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Kasperek, K; Feinendegen, L E

    1976-01-01

    Applied trace elements research in medicine requires a sensitive and efficient technique of trace elements analysis, such as neutron activation analysis. Essential trace elements act as stabilizators (iron in haem), structural elements (silicon in fibrous tissue), in hormones (iodine in thyroid hormone), in vitamins (cobalt in vitamin B 12), and in enzymes. Most of the essential trace elements act as coenzymes or in coenzymes or directly as metabolic catalyzers. For example, selenium deficiency in PKU and maple syrup patients receiving dietary treatment can be detected by determining the selenium content of the serum, while low selenium values in the whole blood indicate liver cirrhosis. Acrodermatitis enteropathica can be diagnosed by determinig zinc in the serum, and pancreatic insufficiency by determining zinc in the pancreatic juice. Zinc also plays a part in disturbances of growth, in the healing of wounds, and in the insulin metabolism. Cobalt is important in some types of anaemia and in myocardiopathies. Trace elements are also necessary in the treatment of diseases, e.g. iron cobalt in some types of anaemia, and zinc in the delayed healing of wounds in the postoperative phase and in acrodermatitis enteropathica. Chromium is now being tested for the treatment of diabetes mellitus, and fluorides may be of interest in the treatment of osteoporosis. Finally, trace elements are important in the aetiology of acute poisoning, in nutrition, and in environmental protection.

  5. Trace element and ΣDDT concentrations in horticultural soils from the Tasman, Waikato and Auckland regions of New Zealand

    International Nuclear Information System (INIS)

    Gaw, S.K.; Wilkins, A.L.; Kim, N.D.; Palmer, G.T.; Robinson, P.

    2006-01-01

    The long-term routine use of agrichemicals can result in elevated levels of trace elements and persistent organic pollutants in soils. Trace element concentrations and ΣDDT levels were measured in soil (0-7.5 cm) samples collected from horticultural and grazing properties in 3 regions of New Zealand (Auckland, Tasman and Waikato). Elevated levels of arsenic ( -1 ), cadmium ( -1 ), copper (5 to 523 mg kg -1 ), lead (5 to 243 mg kg -1 ) and ΣDDT ( -1 ) were detected in soils from all 3 regions. With the exception of cadmium and zinc, significantly higher levels of contaminants were generally detected in horticultural soils than in grazing soils. Our results have implications for the on-going use of agrichemicals as concentrations of cadmium, copper, tin and zinc in some samples exceeded ecotoxicity based soil criteria. The p,p'-DDE : DDT ratios indicate that the degradation of DDT in NZ horticultural soils may be inhibited by the co-contamination with trace elements

  6. Determination of trace amounts of impurities in molybdenum by spark source and glow discharge mass spectrometry

    International Nuclear Information System (INIS)

    Saito, Morimasa

    1994-01-01

    For the determination of trace and ultra-trace amounts of impurities in high-purity molybdenum, spark source mass spectrometry and glow discharge mass spectrometry were studied. In spark source mass spectrometry using the metal probe method, the liquid-helium cryogenic pump was used in order to protect the surface of the samples from oxidation. The theoretical relative sensitivity factors (Mo=1) calculated from physical properties were used. The analytical results obtained for molybdenum tablet and high-purity molybdenum were in good agreement with those obtained by other methods (atomic absorption spectrometry and others). In glow discharge mass spectrometry, the relative sensitivity factors were calculated by using the results obtained by spark source mass spectrometry and atomic absorption spectrometry, and this method was applied to the determination of ultra-trace amounts of impurities in ultra high-purity molybdenum and gave the satisfactory results. The detection limits (2σ, n=10) in the integration time of 600 s for U and Th were 0.6 ppb and 0.3 ppb, and the values for Al, Si, Cr, Mn and Cu were in the range of 10 ppb to 0.5 ppb. (author)

  7. Trace element, semivolatile organic, and chlorinated organic compound concentrations in bed sediments of selected streams at Fort Gordon, Georgia, February-April 2010

    Science.gov (United States)

    Thomas, Lashun K.; Journey, Celeste A.; Stringfield, Whitney J.; Clark, Jimmy M.; Bradley, Paul M.; Wellborn, John B.; Ratliff, Hagan; Abrahamsen, Thomas A.

    2011-01-01

    A spatial survey of streams was conducted from February to April 2010 to assess the concentrations of major ions, selected trace elements, semivolatile organic compounds, organochlorine pesticides, and polychlorinated biphenyls associated with the bed sediments of surface waters at Fort Gordon military installation near Augusta, Georgia. This investigation expanded a previous study conducted in May 1998 by the U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon, that evaluated the streambed sediment quality of selected surface waters at Fort Gordon. The data presented in this report are intended to help evaluate bed sediment quality in relation to guidelines for the protection of aquatic life, and identify temporal trends in trace elements and semivolatile organic compound concentrations at streambed sites previously sampled. Concentrations of 34 major ions and trace elements and 102 semivolatile organic, organochlorine pesticide, and polychlorinated biphenyl compounds were determined in the fine-grained fraction of bed sediment samples collected from 13 of the original 29 sites in the previous study, and 22 additional sites at Fort Gordon. Three of the sites were considered reference sites as they were presumed to be located away from potential sources of contaminants and were selected to represent surface waters flowing onto the fort, and the remaining 32 nonreference sites were presumed to be located within the contamination area at the fort. Temporal trends in trace elements and semivolatile organic compound concentrations also were evaluated at 13 of the 32 nonreference sites to provide an assessment of the variability in the number of detections and concentrations of constituents in bed sediment associated with potential sources, accumulation, and attenuation processes. Major ion and trace element concentrations in fine-grained bed

  8. Hierarchical porous ZnO microflowers with ultra-high ethanol gas-sensing at low concentration

    Science.gov (United States)

    Song, Liming; Yue, He; Li, Haiying; Liu, Li; Li, Yu; Du, Liting; Duan, Haojie; Klyui, N. I.

    2018-05-01

    Hierarchical porous and non-porous ZnO microflowers have been successfully fabricated by hydrothermal method. Their crystal structure, morphology and gas-sensing properties were studied by X-ray diffraction (XRD), scanning electron microscopy (SEM), and chemical gas sensing intelligent analysis system (CGS). Compared with hierarchical non-porous ZnO microflowers, hierarchical porous ZnO microflowers exhibited ultra-high sensitivity with 50 ppm ethanol at 260 °C and the response is 110, which is 1.8 times higher than that of non-porous ZnO microflowers. Moreover, the lowest concentration limit of hierarchical porous ZnO microflowers (non-porous ZnO microflowers) to ethanol is 0.1 (1) ppm, the response value is 1.6 (1).

  9. Ray tracing for optimization of compound parabolic concentrators for solar collectors of enclosed design

    OpenAIRE

    YURCHENKO, VLADIMIR; YURCHENKO, EDUARD; ÇİYDEM, MEHMET; TOTUK, ONAT

    2015-01-01

    We present our developments in computer simulations and optimization of compound parabolic concentrators (CPCs) for solar heat collectors. Issues of both the optical and thermal optimization of CPC collectors of enclosed design are discussed. Ray tracing results for a CPC with a V-shaped absorber are presented. A range of optimal values for the apex angle of a V-shaped absorber is proposed for a CPC collector of typical design.

  10. Evaluation of local trace element status and 8-Iso-prostaglandin F2α concentrations in patients with Tinea pedis.

    Science.gov (United States)

    Miraloglu, Meral; Kurutas, Ergul Belge; Ozturk, Perihan; Arican, Ozer

    2016-01-01

    Tinea pedis (TP) is an infection of the feet caused by fungi. The infectious diseases caused by dermatophytes are mainly related to the enzymes produced by these fungi. Up to the now, the local 8-iso-prostaglandin F2α (8-iso-PGF2α), concentration as oxidative stress biomarker and trace elements status have not been published in patients with TP. The aim of this study is to evaluate the relationship between oxidative stress and trace elements (Cu, Zn, Se), and to evaluate the ratios of Cu/Zn and Cu/Se in this disorder. Forty-three consecutive patients with a diagnosis of unilateral interdigital TP were enrolled in this study. The samples were obtained by scraping the skin surface. 8-iso-PGF2α concentrations in scraping samples were determined by ELISA. In addition, the levels of Se, Zn and Cu in scraping samples were determined on flame and furnace atomic absorption spectrophotometer using Zeeman background correction. Oxidative stress was confirmed by the significant elevation in 8-iso-PGF2α concentrations (p iso-PGF2α parameters, but negative correlations between Se-Cu; Se-8-iso-PGF2α parameters in lesional area. Furthermore, the ratios of Cu/Zn and Cu/Se were significantly higher on the lesional area than the non-lesional area (p iso-PGF2α and trace elements in patients with TP (p > 0.05). Our results showed that there is a possible link between oxidative stress (increased 8-iso-PGF2α concentrations) and imbalanced of trace elements status in lesional area of TP patients. The use of antifungal agents together with both Zn and Se drugs could be helpful in the both regression of disease and in shortening the duration of disease.

  11. How healthy is urban horticulture in high traffic areas? Trace metal concentrations in vegetable crops from plantings within inner city neighbourhoods in Berlin, Germany.

    Science.gov (United States)

    Säumel, Ina; Kotsyuk, Iryna; Hölscher, Marie; Lenkereit, Claudia; Weber, Frauke; Kowarik, Ingo

    2012-06-01

    Food production by urban dwellers is of growing importance in developing and developed countries. Urban horticulture is associated with health risks as crops in urban settings are generally exposed to higher levels of pollutants than those in rural areas. We determined the concentration of trace metals in the biomass of different horticultural crops grown in the inner city of Berlin, Germany, and analysed how the local setting shaped the concentration patterns. We revealed significant differences in trace metal concentrations depending on local traffic, crop species, planting style and building structures, but not on vegetable type. Higher overall traffic burden increased trace metal content in the biomass. The presence of buildings and large masses of vegetation as barriers between crops and roads reduced trace metal content in the biomass. Based on this we discuss consequences for urban horticulture, risk assessment, and planting and monitoring guidelines for cultivation and consumption of crops. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Current status of JAERI program on development of ultra-trace-analytical technology for safeguards environmental samples

    International Nuclear Information System (INIS)

    Adachi, T.; Usuda, S.; Watanabe, K.

    2001-01-01

    Full text: In order to contribute to the strengthened safeguards system based on the Program 93+2 of the IAEA, Japan Atomic Energy Research Institute (JAERI) is developing analytical technology for ultra-trace amounts of nuclear materials in environmental samples, and constructed the CLEAR facility (Clean Laboratory for Environmental Analysis and Research) for this purpose. The development of the technology is carried out, at existing laboratories for time being, in the following fields: screening, bulk analysis and particle analysis. The screening aims at estimating the amounts of nuclear materials in environmental samples to be introduced into the clean rooms, and is the first step to avoid cross-contamination among the samples and contamination of the clean rooms themselves. In addition to ordinary radiation spectrometry, Compton suppression technique was applied to low energy γ- and X-ray measurements, and sufficient reduction in background level has been demonstrated. Another technique in examination is imaging-plate method, which is a kind of autoradiography and suitable for determination of radioactive-particle distribution in the samples as well as for semiquantitative determination. As for the bulk analysis, the efforts are temporally made on uranium in swipe samples. Preliminary examination for optimization of sample pre-treatment conditions is in progress. At present, ashing by low-temperature-plasma method gives better results than high-temperature ashing or acid leaching. For the isotopic ratio measurement, instrumental performance of inductively-coupled plasma mass spectrometry (ICP-MS) are mainly examined because sample preparation for ICP-MS is simpler than that for thermal ionization mass spectrometry (TIMS). It was found by our measurement that the swipe material (TexWipe TX304, usually used by IAEA) contains un-negligible uranium blank with large deviation (2-6 ng/sheet). This would introduce significant uncertainty in the trace analysis. JAERI

  13. Transport of trace metals in the Magela Creek system, Northern Territory. II. Trace metal concentrations in the Magela Creek billabongs at the end of the 1978 dry season

    International Nuclear Information System (INIS)

    Davies, S.H.R.; Hart, B.T.

    1981-12-01

    Billabongs downstream of the Ranger uranium mining operation have been identified as potential deposition areas for released trace metals. Samples were taken at the end of the dry season and analysed for total and filterable concentrations of Fe, Mn, Cd, Cu and Zn. There was an increase in the concentrations of total Fe, Zn, Cd and Cu in the backflow and flood plain billabongs compared with the concentrations recorded during the wet season. The increase was most noticeable for iron

  14. Metrology of trace radionuclides in environment. Standardization and traceability

    International Nuclear Information System (INIS)

    Calmet, D.

    1999-01-01

    Widespread concern over radioactive substances in the environment regularly requires environmental and public health assessments. The credibility of an assessment will depend on the quality and reliability on measurement results that often are of paramount significance in the environmental domain. Those man made radionuclides present in the various environmental components of the French territory are however found at trace, even ultra-trace levels. This article gives an overview of standardization work and required reference materials and rules for measuring radionuclides in environmental matrices as well as the international and national systems to manage standardization and traceability. Some achievements as well as the many difficulties that the metrologist must overcome when using nuclear techniques to measure trace quantities of radionuclides are presented. (author)

  15. Species-and stage-specific differences in trace element tissue concentrations in amphibians: implications for the disposal of coal-combustion wastes

    International Nuclear Information System (INIS)

    Roe, John H.; Hopkins, William A.; Jackson, Brian P.

    2005-01-01

    Information on species-and stage-specific patterns of contaminant accumulation is generally lacking for amphibians, yet such information could provide valuable knowledge on how amphibians interact with contaminants. We assessed concentrations of As, Cd, Cu, Ni, Pb, Se, Sr, and Zn in whole bodies of larval, recently metamorphosed, and adult life stages in Bufo terrestris and Rana sphenocephala from a site that currently receives coal combustion waste (CCW) discharge, a site where CCW was formerly discharged that has undergone natural attenuation for 30 years, and a nearby reference site. For the majority of elements (As, Cd, Cu, Ni, Pb, Zn), concentrations were highest in larvae, but Se and Sr concentrations remained elevated in later life stages, likely because these elements are S and Ca analogs, respectively, and are thus retained throughout structural changes during metamorphosis. Element concentrations were generally higher in B. terrestris than in R. sphenocephala. Concentrations of As, Se, and Sr were up to 11-35 times higher in metamorphs emigrating from CCW-polluted wetlands compared to unpolluted wetlands, suggesting metamorphosed amphibians can transport trace elements from aquatic disposal basins to nearby uncontaminated terrestrial habitats. In addition, anurans utilizing naturally revegetated sites up to 30 years after CCW disposal ceases are exposed to trace elements, although to a lesser degree than sites where CCW is currently discharged. - Results suggest that metamorphosed amphibians can transport trace elements from aquatic disposal basins to non-contaminated habitats

  16. Species-and stage-specific differences in trace element tissue concentrations in amphibians: implications for the disposal of coal-combustion wastes

    Energy Technology Data Exchange (ETDEWEB)

    Roe, John H. [University of Georgia, Savannah River Ecology Laboratory, P.O. Drawer E, Aiken, SC 29802 (United States); Hopkins, William A. [University of Georgia, Savannah River Ecology Laboratory, P.O. Drawer E, Aiken, SC 29802 (United States)]. E-mail: hopkins@srel.edu; Jackson, Brian P. [University of Georgia, Savannah River Ecology Laboratory, P.O. Drawer E, Aiken, SC 29802 (United States)

    2005-07-15

    Information on species-and stage-specific patterns of contaminant accumulation is generally lacking for amphibians, yet such information could provide valuable knowledge on how amphibians interact with contaminants. We assessed concentrations of As, Cd, Cu, Ni, Pb, Se, Sr, and Zn in whole bodies of larval, recently metamorphosed, and adult life stages in Bufo terrestris and Rana sphenocephala from a site that currently receives coal combustion waste (CCW) discharge, a site where CCW was formerly discharged that has undergone natural attenuation for 30 years, and a nearby reference site. For the majority of elements (As, Cd, Cu, Ni, Pb, Zn), concentrations were highest in larvae, but Se and Sr concentrations remained elevated in later life stages, likely because these elements are S and Ca analogs, respectively, and are thus retained throughout structural changes during metamorphosis. Element concentrations were generally higher in B. terrestris than in R. sphenocephala. Concentrations of As, Se, and Sr were up to 11-35 times higher in metamorphs emigrating from CCW-polluted wetlands compared to unpolluted wetlands, suggesting metamorphosed amphibians can transport trace elements from aquatic disposal basins to nearby uncontaminated terrestrial habitats. In addition, anurans utilizing naturally revegetated sites up to 30 years after CCW disposal ceases are exposed to trace elements, although to a lesser degree than sites where CCW is currently discharged. - Results suggest that metamorphosed amphibians can transport trace elements from aquatic disposal basins to non-contaminated habitats.

  17. Role of primary substrate composition and concentration on attenuation of trace organic chemicals in managed aquifer recharge systems

    KAUST Repository

    Alidina, Mazahirali; Li, Dong; Ouf, Mohamed; Drewes, Jorg

    2014-01-01

    This study was undertaken to investigate the role of primary substrate composition and concentration on the attenuation of biodegradable emerging trace organic chemicals (TOrCs) in simulated managed aquifer recharge (MAR) systems. Four sets of soil

  18. Determination of isoniazid concentration in rabbit vertebrae by isotope tracing technique in conjunction with HPLC.

    Science.gov (United States)

    Liu, Peng; Fu, Zhaozong; Jiang, Jianming; Yuan, Liang; Lin, Zhen

    2013-09-01

    Medications compounded with isoniazid (INH) are usually applied to surgical sites at the completion of surgery to locally kill postoperative residual tubercle bacilli. However, the distribution and elimination of INH in the vertebrae in vivo are not known. In this study, isotope tracing was used in conjunction with high-pressure liquid chromatography (HPLC) to address this. INH and technetium-99 m-labeled INH were applied to the vertebrae of rabbits. After 2 and 6 h, osseous tissues containing INH, as determined by radionuclide imaging, were collected for detection with HPLC. The results showed that INH mainly stayed around the vertebrae 6 h after its application and did not permeate widely into the blood or other organs, except for the kidneys. The standard deviations of INH concentrations in the technetium-99 m-INH group were approximately four-fold smaller than those in the INH group. This method of coupling isotope tracing and HPLC can effectively limit experimental error during sample collection, allowing accurate and reliable identification of the concentration levels of INH in osseous tissues in vivo. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Trace element concentrations in freshwater mussels and macrophytes as related to those in their environment

    Directory of Open Access Journals (Sweden)

    Gian Maria BEONE

    2003-02-01

    Full Text Available This study was primarily designed to contribute to the debate "Do accumulator species reflect the element contamination level of their environment?" This research was carried out: 1 to know the distribution of 15 trace elements and calcium in shell and soft tissues of three species of freshwater mussels and macrophytes; 2 to compare the accumulation capacity of each trace element by mussels and by eight species of macrophytes and 3 to test the relationships between the metal concentrations in the mussels and macrophytes and those in water and sediments. The variability of element residues in the mussels is the major limit to accumulator monitoring. The most important causes are: seasonal cycle, physical environment and biological factors such as the size, age and growth rate. This research was designed to eliminate the consequence of variability deriving from the season and the environment. To this end the mussels and macrophytes were collected at the same time from the same habitat: Ranco Bay, Lago Maggiore, Northern Italy. In addition, the element concentrations in more size-classes of the most abundant mussel species (Unio pictorum and Dreissena polymorpha were measured. Trace elements were analyzed by Inductive Coupled Plasma-Mass Spectrometry (ICP-MS. By arranging the data in sequences of decreasing element concentrations in the organisms as well as in water and sediments, we were able to compare the accumulating ability of the tested species and evaluate their capacity to reflect environmental availability. Neither the sequences in the shell nor those in the tissues were similar to the sequence in the water. The differences between the sequences of the mussel tissues and those of the sediments were less striking than those between shells and sediments. Similar results were obtained by macrophytes. In conclusion, the results of this study (which mimics the monitoring practice prove that bioaccumulators cannot be used to evaluate the

  20. Differences in trace element concentrations between the right and left hemispheres of human brain using INAA

    International Nuclear Information System (INIS)

    Panayi, A.E.; Surrey Univ.; Spyrou, N.M.; Akanle, O.A.; Ubertalli, L.C.; Part, P.

    2000-01-01

    Very few publications have quoted differences between the same regions in both the right and left hemispheres of the human brain. It may be possible that the two hemispheres have different trace elemental concentrations, since it is known that they both have different functions. In this study, three brain regions from both the right and left hemispheres of the cortex have been sampled from five elderly individuals (three 'normal' and two Alzheimer's disease) and their elemental concentrations have been determined by instrumental neutron activation analysis (INAA). (author)

  1. Historical record of concentrations of atmospheric trace components deduced from a glacier in the Alps

    International Nuclear Information System (INIS)

    Doescher, A.

    1996-07-01

    A 109 m ice core from a high-alpine glacier (Colle Gnifetti, Monte Rosa massif, 4440 m a.s.l., Switzerland) was used to reconstruct the history of atmospheric trace components. Concentrations of the anions chloride, nitrate, sulfate and the cations sodium, ammonium, potassium, magnesium and calcium were measured with 2.5-5.0 cm resolution in the top 70 m of a 109 m long of the ice core. Dating of the ice core was performed using stratigraphic markers such as historically known Saharan dust events, the atomic bomb horizon and volcanic eruptions and supplemented with the 210 Pb nuclear dating. The record covers the time period from about 1755-1981. The concentrations of nitrate and sulfate show an exponential increase from 1930 and 1870 until 1965, respectively. The factors of increase were 2.3±0.3 and 5.8±0.9, respectively. The chloride concentrations remained constant during this period. A good agreement between the concentrations of sulfate, which were corrected for the contribution of seasalt and mineral dust and the European SO 2 -emissions was found for the last 100 years. The concentrations of sodium, potassium, magnesium and calcium did not show a trend. The concentrations of ammonium increased exponentially between 1870 and 1960 by a factor of 2.2±0.4. The different sources of the trace components were identified using correlation analysis. Sodium and chloride originated from seasalt, magnesium and calcium from geologic erosion. For both, the industrial and pre-industrial period, the dominant source of ammonium and nitrate was conversion of the gaseous precursors NH 3 and HNO 3 . Sulfate concentrations in the industrial period originated from the anthropogenically emitted SO 2 , whereas in the pre-industrial period the geologic source dominated. The Colle Gnifetti accumulates mainly summer snow, and therefore, several test drillings were performed to find a new site with higher accumulation rate. (author) figs., 17 tabs., 50 refs

  2. CONCENTRATION OF SELECTED ELEMENTS IN RAW AND ULTRA HEAT TREATED COW MILK

    Directory of Open Access Journals (Sweden)

    Lukáčová Anetta

    2012-10-01

    Full Text Available The potential presence of toxic metals in food is being recognized as a priority by standards organizations and constitutes an analytical challenge. The toxic metal content of milk and dairy products is due to several factors: environmental conditions, the manufacturing process and the possible contamination during several steps of the manufacturing processes. The aim of this study was to evaluate samples of raw milk with fat contents 3.8% obtained at randomly from animal farms in around Nitra, western Slovakia region and ultra – heat treated cow milk (UHT with fat contents 1.5% commercially available from local market in Nitra. Samples of milk were analysed for metal contents using atomic absorption spectrophotometry (AAS. UHT milk showed higher levels of cadmium, nickel and iron. Higher levels of zinc, copper were detected in raw milk. Significant differences in the concentration of copper between raw and UHT cow milk were found.

  3. Molecularly imprinted sensor based on Russian Matryoshka structured molecules for enhanced specific identification and double amplification in ultra-trace Tb3+ determination.

    Science.gov (United States)

    Li, Jianping; Yang, Bin; Pan, Hongcheng; Xu, Guobao

    2018-06-30

    The selective and sensitive detection of rare earth elements is thought to be difficult because the concentration of those elements in the sample is commonly at a low level and they normally have severe mutual interference which is caused by homologous chemical properties. In this study, a novel molecularly imprinted polymer (MIP) sensor was fabricated for highly sensitive and selective determination of ultra-trace Tb 3+ . The Tb 3+ -ethylenediaminetetraacetic acid complex (Tb-EDTA) as the template molecule was incorporated into mono-6-mercapto-β-cyclodextrin (mono-6-SH-β-CD) to form a Russian Matryoshka (RM)-structured molecule (CD/Tb-EDTA). Titanium isopropoxide was utilized in vapor sol-gel polymerization to construct MIP membrane. Moreover, the selectivity of the RM MIP sensor was remarkably enhanced by the "triple-selectivity" recognition of EDTA-to-Tb 3+ , β-CD-to-(Tb-EDTA), and 3D cavity-to-(CD/Tb-EDTA), while the sensitivity of the MIP sensor was significantly improved by ECL signal enhancement based on double amplification, in other words, the electrochemiluminescence resonance energy transfer (ECL-RET) between the ECL donor of CD/Tb-EDTA and the ECL acceptor of Ru(bpy) 3 2+ , and the ECL enhancement by the co-reactant of CD/Tb-EDTA on Ru(bpy) 3 Cl 2 . When the imprinted cavities were occupied by Tb-EDTA during rebinding, the host-guest inclusion structured complex was formed and the ECL intensities produced by the Ru(bpy) 3 Cl 2 ECL system increased with increasing concentration of Tb-EDTA. The proposed sensor was used for quantitative analysis of Tb 3+ with concentrations ranging from 8.00 × 10 -13 mol/L to 4.00 × 10 -9 mol/L and successfully applied to detect Tb 3+ in seawater samples. The detection limit of the sensor was found to be 3.90 × 10 -13 mol/L (DL = 3δ b /K), which is lower than previously reported values. Thus, the fabricated sensor is feasible for practical applications. Copyright © 2018 Elsevier B.V. All rights

  4. Use of neutron activation analysis to measure the variation in trace element concentrations in a coal seam

    International Nuclear Information System (INIS)

    Fardy, J.J.; Swaine, D.J.

    1985-01-01

    Trace element concentrations were measured by neutron activation on 57 run-of-mine coal samples from several locations in seven mines located in the Lithgow seam in the Western Coalfield, Sydney Basin. Results were tabulated as ratios of the highest to the lowest variance for each element

  5. Hepatic and renal concentrations of 10 trace elements in crocodiles (Crocodylus niloticus) in the Kafue and Luangwa rivers in Zambia

    Energy Technology Data Exchange (ETDEWEB)

    Almli, Bjorn [National Veterinary Institute, POB 8156 Dep., N-0033 Oslo (Norway)]. E-mail: bjorn.almli@vetinst.no; Mwase, Maxwell [Samora Machel School of Veterinary Medicine, University of Zambia, POB 32379, Lusaka (Zambia); Sivertsen, Tore [Norwegian School of Veterinary Science, POB 8146 Dep., N-0033 Oslo (Norway); Musonda, Mike [Samora Machel School of Veterinary Medicine, University of Zambia, POB 32379, Lusaka (Zambia); Flaoyen, Arne [National Veterinary Institute, POB 8156 Dep., N-0033 Oslo (Norway); Norwegian School of Veterinary Science, POB 8146 Dep., N-0033 Oslo (Norway)

    2005-01-20

    Hepatic and renal concentrations of the elements arsenic, cadmium, cobalt, copper, lead, manganese, mercury, molybdenum, selenium and zinc were determined in samples collected from four crocodiles from the Kafue River, Kafue National Park and five crocodiles from the Luangwa River, Luangwa National Park, Zambia. The concentrations of the essential elements were similar to those reported in other vertebrates. Arsenic and cadmium concentrations were low (medians below 0.05 {mu}g As/g and below 0.16 {mu}g Cd/g, wet wt.). Mercury and lead concentrations were several orders of magnitude higher (medians up to 3.7 {mu}g Hg/g, and up to 8.7 {mu}g Pb/g, all wet wt.) than in hippopotami from the same rivers, probably as a result of food-chain biomagnification. Judging by the results obtained in this study, pollution from the mining activity around the Kafue River drainage area in the Copperbelt region has not significantly influenced the trace element concentrations in tissues of the crocodiles in the Kafue National Park. The trace element concentrations measured may serve as reference values in future studies on crocodilians.

  6. Correlation between sub-micron surface roughness of iron oxide encrustations and trace element concentrations

    International Nuclear Information System (INIS)

    Fischer, Cornelius; Karius, Volker; Luettge, Andreas

    2009-01-01

    Iron oxide encrustations are formed on black slate surfaces during oxidative weathering of iron sulfide and phosphate bearing, organic matter-rich slates. Synchronously, trace elements are released during ongoing weathering. Laser ablation ICP-MS analyses of a weathered and encrusted slate showed that major portions of the V, Cu, As, Mo, Pb, Th, and U reside in the encrustation. Recently a potential relationship between several micrometer to 500 nm surface topography roughness of such encrustations and its uranium concentration was shown. Based on laser scanning microscopy measurements, the present study shows that this interrelation must be expanded to small submicron-sized half-pores with diameters between 100 nm and 500 nm. We demonstrate that the relationship is not limited to topography variations of a single encrustation in the hand-specimen scale. Surface topography and geochemical analyses of iron oxide encrustations from several locations but from the same geochemical environment and with similar weathering history showed that the concentrations of U, P, Cu, and Zn correlate inversely with the surface roughness parameter F. This parameter represents the total surface area and is - in this case - a proxy for the root-mean square surface roughness Rq. This study substantiates the environmental importance that micrometer- to submicrometer topography variations of fluid-rock interfaces govern the trapping of trace elements.

  7. Correlation between sub-micron surface roughness of iron oxide encrustations and trace element concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Cornelius, E-mail: cornelius@rice.edu [Department of Earth Science, MS-126, Rice University, 6100 Main Street, Houston, TX 77005 (United States); Geowissenschaftliches Zentrum der Universitaet Goettingen, Abt. Sedimentologie and Umweltgeologie, Goldschmidtstr. 3, D-37077 Goettingen (Germany); Karius, Volker [Geowissenschaftliches Zentrum der Universitaet Goettingen, Abt. Sedimentologie and Umweltgeologie, Goldschmidtstr. 3, D-37077 Goettingen (Germany); Luettge, Andreas [Department of Earth Science, MS-126, Rice University, 6100 Main Street, Houston, TX 77005 (United States); Department of Chemistry, Rice University, 6100 Main Street, Houston, TX 77005 (United States)

    2009-08-01

    Iron oxide encrustations are formed on black slate surfaces during oxidative weathering of iron sulfide and phosphate bearing, organic matter-rich slates. Synchronously, trace elements are released during ongoing weathering. Laser ablation ICP-MS analyses of a weathered and encrusted slate showed that major portions of the V, Cu, As, Mo, Pb, Th, and U reside in the encrustation. Recently a potential relationship between several micrometer to 500 nm surface topography roughness of such encrustations and its uranium concentration was shown. Based on laser scanning microscopy measurements, the present study shows that this interrelation must be expanded to small submicron-sized half-pores with diameters between 100 nm and 500 nm. We demonstrate that the relationship is not limited to topography variations of a single encrustation in the hand-specimen scale. Surface topography and geochemical analyses of iron oxide encrustations from several locations but from the same geochemical environment and with similar weathering history showed that the concentrations of U, P, Cu, and Zn correlate inversely with the surface roughness parameter F. This parameter represents the total surface area and is - in this case - a proxy for the root-mean square surface roughness Rq. This study substantiates the environmental importance that micrometer- to submicrometer topography variations of fluid-rock interfaces govern the trapping of trace elements.

  8. Stimulatory and protective effects of alkylating agents applied in ultra-low concentrations.

    Science.gov (United States)

    Pukhalsky, A L; Shmarina, G V

    2001-01-01

    Alkylating drugs belonging to the nitrogen mustard family are known as cytostatic and immunosuppressive agents. Ultra-low doses of these drugs may demonstrate pharmacological effects unlike this category of drugs. In the case of a gradual dose decrease, the number of targets for alkylation is also reduced and the drug switches from cytostatic to cell growth modifier. We postulate that application of ultra-low doses of alkylating drugs may result in a beneficial effect in the therapy of diseases associated with chronic inflammation of the mucosa, especially with the signs of epithelial atrophy. Copyright 2001 S. Karger AG, Basel

  9. Combined micro-droplet and thin-film-assisted pre-concentration of lead traces for on-line monitoring using anodic stripping voltammetry.

    Science.gov (United States)

    Belostotsky, Inessa; Gridin, Vladimir V; Schechter, Israel; Yarnitzky, Chaim N

    2003-02-01

    An improved analytical method for airborne lead traces is reported. It is based on using a Venturi scrubber sampling device for simultaneous thin-film stripping and droplet entrapment of aerosol influxes. At least threefold enhancement of the lead-trace pre-concentration is achieved. The sampled traces are analyzed by square-wave anodic stripping voltammetry. The method was tested by a series of pilot experiments. These were performed using contaminant-controlled air intakes. Reproducible calibration plots were obtained. The data were validated by traditional analysis using filter sampling. LODs are comparable with the conventional techniques. The method was successfully applied to on-line and in situ environmental monitoring of lead.

  10. Combined micro-droplet and thin-film-assisted pre-concentration of lead traces for on-line monitoring using anodic stripping voltammetry

    Energy Technology Data Exchange (ETDEWEB)

    Belostotsky, Inessa; Gridin, Vladimir V.; Schechter, Israel; Yarnitzky, Chaim N. [Department of Chemistry, Technion Israel Institute of Technology, 32000, Haifa (Israel)

    2003-02-01

    An improved analytical method for airborne lead traces is reported. It is based on using a Venturi scrubber sampling device for simultaneous thin-film stripping and droplet entrapment of aerosol influxes. At least threefold enhancement of the lead-trace pre-concentration is achieved. The sampled traces are analyzed by square-wave anodic stripping voltammetry. The method was tested by a series of pilot experiments. These were performed using contaminant-controlled air intakes. Reproducible calibration plots were obtained. The data were validated by traditional analysis using filter sampling. LODs are comparable with the conventional techniques. The method was successfully applied to on-line and in situ environmental monitoring of lead. (orig.)

  11. Trace Element Concentration and Speciation in Selected Mining-Contaminated Soils and Water in Willow Creek Floodplain, Colorado

    Directory of Open Access Journals (Sweden)

    R. Burt

    2011-01-01

    Full Text Available Long-term mining activities in the mountains around Creede, Colorado have resulted in significant contamination in soils and water in the Willow Creek floodplain. Total major and trace were determined for soils and water and sequential chemical extraction for soils. Objectives were to determine concentrations and potential reactivity of trace elements and investigate their relationship with other soil and water properties. Water trace elements showed significant variability among sites, ranging from 347 to 12108 μg/L. Relative trend showed (Zn > Sr > Ba > (Mn > W > Cd > (Sn > V ≈ Ni ≈ Cu > Co > (Ag. Soil trace elements showed significant short-range spatial variability, ranging from 2819 to 19274 mg/kg. Relative trend showed (Pb ≈ Zn > Mn > Ba > P > (As > Cu > Sr > V > Cd > Sb ≈ Ag > (Co ≈ Cr > Mo ≈ Sn ≈ Ni > (Be ≈ W > Se ≈ Hg. Predominant fractions were oxide, specifically-sorbed/carbonate bound, and residual. Water soluble and exchangeable fractions showed (Zn ≈ Cd > Pb and Cd > Zn > Pb, respectively. Mobility factors for highly contaminated soils showed Cd ≈ Zn > Pb > Cu > As.

  12. On the distribution of trace element concentrations in multiple bone elements in 10 Danish medieval and post-medieval individuals.

    Science.gov (United States)

    Lund Rasmussen, Kaare; Skytte, Lilian; D'imporzano, Paolo; Orla Thomsen, Per; Søvsø, Morten; Lier Boldsen, Jesper

    2017-01-01

    The differences in trace element concentrations among 19 different bone elements procured from 10 archaeologically derived human skeletons have been investigated. The 10 individuals are dated archaeologically and some by radiocarbon dating to the medieval and post-medieval period, an interval from ca. AD 1150 to ca. AD 1810. This study is relevant for two reasons. First, most archaeometric studies analyze only one bone sample from each individual; so to what degree are the bones in the human body equal in trace element chemistry? Second, differences in turnover time of the bone elements makes the cortical tissues record the trace element concentrations in equilibrium with the blood stream over a longer time earlier in life than the trabecular. Therefore, any differences in trace element concentrations between the bone elements can yield what can be termed a chemical life history of the individual, revealing changes in diet, provenance, or medication throughout life. Thorough decontamination and strict exclusion of non-viable data has secured a dataset of high quality. The measurements were carried out using Inductively Coupled Plasma Mass Spectrometry (for Fe, Mn, Al, Ca, Mg, Na, Ba, Sr, Zn, Pb and As) and Cold Vapor Atomic Absorption Spectroscopy (for Hg) on ca. 20 mg samples. Twelve major and trace elements have been measured on 19 bone elements from 10 different individuals interred at five cemeteries widely distributed in medieval and renaissance Denmark. The ranges of the concentrations of elements were: Na (2240-5660 µg g -1 ), Mg (440-2490 µg g -1 ), Al (9-2030 µg g -1 ), Ca (22-36 wt. %), Mn (5-11450 µg g -1 ), Fe (32-41850 µg g -1 ), Zn (69-2610 µg g -1 ), As (0.4-120 µg g -1 ), Sr (101-815 µg g -1 ), Ba (8-880 µg g -1 ), Hg (7-78730 ng g -1 ), and Pb (0.8-426 µg g -1 ). It is found that excess As is mainly of diagenetic origin. The results support that Ba and Sr concentrations are effective provenance or dietary indicators. Migrating

  13. Ultra-fast low concentration detection of Candida pathogens utilizing high resolution micropore chips.

    Science.gov (United States)

    Mulero, Rafael; Lee, Dong Heun; Kutzler, Michele A; Jacobson, Jeffrey M; Kim, Min Jun

    2009-01-01

    Although Candida species are the fourth most common cause of nosocomial blood stream infections in the United States, early diagnostic tools for invasive candidemia are lacking. Due to an increasing rate of candidemia, a new screening system is needed to detect the Candida species in a timely manner. Here we describe a novel method of detection using a solid-state micro-scale pore similar to the operational principles of a Coulter counter. With a steady electrolyte current flowing through the pore, measurements are taken of changes in the current corresponding to the shape of individual yeasts as they translocate or travel through the pore. The direct ultra-fast low concentration electrical addressing of C. albicans has established criteria for distinguishing individual yeast based on their structural properties, which may reduce the currently used methods' complexity for both identification and quantification capabilities in mixed blood samples.

  14. Ultra-Fast Low Concentration Detection of Candida Pathogens Utilizing High Resolution Micropore Chips

    Directory of Open Access Journals (Sweden)

    2009-03-01

    Full Text Available Although Candida species are the fourth most common cause of nosocomial blood stream infections in the United States, early diagnostic tools for invasive candidemia are lacking. Due to an increasing rate of candidemia, a new screening system is needed to detect the Candida species in a timely manner. Here we describe a novel method of detection using a solid-state micro-scale pore similar to the operational principles of a Coulter counter. With a steady electrolyte current flowing through the pore, measurements are taken of changes in the current corresponding to the shape of individual yeasts as they translocate or travel through the pore. The direct ultra-fast low concentration electrical addressing of C. albicans has established criteria for distinguishing individual yeast based on their structural properties, which may reduce the currently used methods’ complexity for both identification and quantification capabilities in mixed blood samples

  15. The role of sample preparation in interpretation of trace element concentration variability in moss bioindication studies

    Science.gov (United States)

    Migaszewski, Z.M.; Lamothe, P.J.; Crock, J.G.; Galuszka, A.; Dolegowska, S.

    2011-01-01

    Trace element concentrations in plant bioindicators are often determined to assess the quality of the environment. Instrumental methods used for trace element determination require digestion of samples. There are different methods of sample preparation for trace element analysis, and the selection of the best method should be fitted for the purpose of a study. Our hypothesis is that the method of sample preparation is important for interpretation of the results. Here we compare the results of 36 element determinations performed by ICP-MS on ashed and on acid-digested (HNO3, H2O2) samples of two moss species (Hylocomium splendens and Pleurozium schreberi) collected in Alaska and in south-central Poland. We found that dry ashing of the moss samples prior to analysis resulted in considerably lower detection limits of all the elements examined. We also show that this sample preparation technique facilitated the determination of interregional and interspecies differences in the chemistry of trace elements. Compared to the Polish mosses, the Alaskan mosses displayed more positive correlations of the major rock-forming elements with ash content, reflecting those elements' geogenic origin. Of the two moss species, P. schreberi from both Alaska and Poland was also highlighted by a larger number of positive element pair correlations. The cluster analysis suggests that the more uniform element distribution pattern of the Polish mosses primarily reflects regional air pollution sources. Our study has shown that the method of sample preparation is an important factor in statistical interpretation of the results of trace element determinations. ?? 2010 Springer-Verlag.

  16. Trace Elements in Human Tooth Enamel

    Energy Technology Data Exchange (ETDEWEB)

    Nixon, G. S. [Turner Dental School, University Of Manchester, Manchester (United Kingdom); Smith, H.; Livingston, H. D. [Department of Forensic Medicine, University Of Glasgow, Glasgow (United Kingdom)

    1967-10-15

    The trace elements are considered to play a role in the resistance of teeth to dental caries. The exact mechanism by which they act has not yet been fully established. Estimations of trace elements have been undertaken in sound human teeth. By means of activation analysis it has been possible to determine trace element concentrations in different layers of enamel in the same tooth. The concentrations of the following elements have been determined: arsenic, antimony, copper, zinc, manganese, mercury, molybdenum and vanadium. The distribution of trace elements in enamel varies from those with a narrow range, such as manganese, to those with a broad range, such as antimony. The elements present in the broad range are considered to be non-essential and their presence is thought to result from a chance incorporation into the enamel. Those in the narrow range appear to be essential trace elements and are present in amounts which do not vary unduly from other body tissues. Only manganese and zinc were found in higher concentrations in the surface layer of enamel compared with the inner layers. The importance of the concentration of trace elements on this surface layer of enamel is emphasized as this layer is the site of the first attack by the carious process. (author)

  17. Combination of solid phase extraction and dispersive liquid–liquid microextraction for separation/preconcentration of ultra trace amounts of uranium prior to its fiber optic-linear array spectrophotometry determination

    International Nuclear Information System (INIS)

    Dadfarnia, Shayessteh; Shabani, Ali Mohammad Haji; Shakerian, Farid; Shiralian Esfahani, Golnaz

    2013-01-01

    Graphical abstract: Pass the sample through the basic alumina column ⇒ elute retained uranium along with the cations ⇒ convert the uranium to its anionic benzoate complex ⇒ extract its ion pair with malachite green into small volume of chloroform by DLLME ⇒ measure its absorption at 621 nm using fiber optic-linear array detection spectrophotometry. -- Highlights: • By combination of SPE and DDLME a high preconcentration factor of 2500 was obtained. • Development of SPE-DDLME-Spectrophotometric method for det. of trace amounts of uranium. • Ultra trace amount of uranium in water samples was det. by the proposed method. • The detection limit of the proposed method is comparable to the most sensitive method. • The proposed method is a free interference spectrophotometric method for uranium det. -- Abstract: A simple and sensitive method for the separation and preconcentration of the ultra trace amounts of uranium and its determination by spectrophotometry was developed. The method is based on the combination of solid phase extraction and dispersive liquid–liquid microextraction. Thus, by passing the sample through the basic alumina column, the uranyl ion and some cations are separated from the sample matrix. The retained uranyl ion along with the cations are eluted with 5 mL of nitric acid (2 mol L −1 ) and after neutralization of the eluent, the extracted uranyl ion is converted to its anionic benzoate complex and is separated from other cations by extraction of its ion pair with malachite green into small volume of chloroform using dispersive liquid–liquid microextraction. The amount of uranium is then determined by the absorption measurement of the extracted ion pair at 621 nm using flow injection spectrophotometry. Under the optimum conditions, with 500 mL of the sample, a preconcentration factor of 1980, a detection limit of 40 ng L −1 , and a relative standard deviation of 4.1% (n = 6) at 400 ng L −1 were obtained. The method was

  18. Evaluation of the trace elements and the total mercury concentration in fishes commercialized at the Cubatao city, Sao Paulo, Brazil

    International Nuclear Information System (INIS)

    Fonseca, Barbara C.; Farias, Luciana A.; Curcho, Michel R.M.; Favaro, Debora I.T.; Braga, Elisabete S.

    2009-01-01

    This paper evaluates the total Hg and the trace elements As, Br, Co, Cr and Rb concentrations in muscle of commercially important fishes at the Cubatao, Sao Paulo, Brazil, region. The following carnivore species were analysed: jew fish (Micropogonias furnieri), girl leg (Menticirrhus americanus), hake (Macrodon ancylodon), and plant eaters, sardine (Sardella braziliensis) and grey mullet (Mugil liza), representing a total of 58 samples. The analysed trace elements were determined through the neutron analysis activation (NAA) and total Hg, through the atomic absorption spectrometry with cold vapor generation (CV AAS). The analysed elements present a great concentration variation, not only among individuals of the same specie, but also among all the analysed species. The total Hg concentration were highly significant, with the predator species jew fish, girl leg and hake presenting concentrations larger than the non predator species sardine and grey mullet. Nevertheless, the content of total Hg remained bellow the limits established by the Brazilian legislation which is the 500 μg kg -1 for the non predator species, and the 1000 μg -1 for the predator species (humid weight)

  19. Trace metal concentrations in Posidonia oceanica of North Corsica (northwestern Mediterranean Sea: use as a biological monitor?

    Directory of Open Access Journals (Sweden)

    Gosselin Marc

    2006-09-01

    Full Text Available Abstract Background Within semi-closed areas like the Mediterranean Sea, anthropic wastes tend to concentrate in the environment. Metals, in particular, are known to persist in the environment and can affect human health due to accumulation in the food chain. The seagrass Posidonia oceanica, widely found in Mediterranean coastal waters, has been chosen as a "sentinel" to quantify the distribution of such pollutants within the marine environment. Using a technique similar to dendrochronology in trees, it can act as an indicator of pollutant levels over a timeframe of several months to years. In the present study, we measured and compared the levels of eight trace metals (Cr, Ni, Cu, Zn, As, Se, Cd, and Pb in sheaths dated by lepidochronology and in leaves of shoots sampled from P. oceanica meadows collected from six offshore sites in northern Corsica between 1988 and 2004; in the aim to determine 1 the spatial and 2 temporal variations of these metals in these areas and 3 to compared these two types of tissues. Results We found low trace metal concentrations with no increase over the last decade, confirming the potential use of Corsican seagrass beds as reference sites for the Mediterranean Sea. Temporal trends of trace metal concentrations in sheaths were not significant for Cr, Ni, Cu, As or Se, but Zn, Cd, and Pb levels decreased, probably due to the reduced anthropic use of these metals. Similar temporal trends between Cu levels in leaves (living tissue and in sheaths (dead tissue demonstrated that lepidochronology linked with Cu monitoring is effective for surveying the temporal variability of this metal. Conclusion Leaves of P. oceanica can give an indication of the metal concentration in the environment over a short time period (months with good accuracy. On the contrary, sheaths, which gave an indication of changes over long time periods (decades, seem to be less sensitive to variations in the metal concentration in the environment

  20. A study of trace element concentrations in human hair of some local populations in Japan. II. Inhabitants of a Japanese rural area

    International Nuclear Information System (INIS)

    Sakurai, S.; Tsunoda, H.; Terai, M.; Yukawa, M.; Tomura, K.; Suzuki-Yasumoto, M.

    1979-01-01

    Hair, as a route by which many metals are excreted, has advantages over other tissues as an indicator of body burden. However, as few data exist on trace element concentrations in hair, a study was made on a rural population in Japan. Hair was collected from 107 residents engaged mainly in dairy farming in a rural area in the northern part of the country. Samples were taken from subjects who had been born and bred in the area which is believed to be free from environmental pollution. A large number of the families had lived there for generations. Nineteen trace elements were detected. The mean values for Hg in hair were 6.8+-2.9 ppm for males and 4.5+-2.7 ppm for females. There was a low statistical correlation between Hg and Se. The mean value for Cu in hair was 17+-7.2 ppm for males and 16+-5.7 ppm for females and that for Zn was 140+-61 ppm for males and 130+-63 ppm for females. A comparison of the mean values of the trace elements in the hair of the subjects aged 20-39 and 40-59 years showed significant differences for Mn in males and Mn and Br in females. A comparison of the findings for the two sexes showed that the concentrations of Mn, Mg, Ca and Br were much higher in females than in males. In contrast, the concentrations of Hg were higher in males than in females. It is suggested that the values obtained for the trace elements in the present study are examples of normal values for trace elements in hair of the Japanese populations. (author)

  1. Concentration of trace elements in feathers of three Antarctic penguins: Geographical and interspecific differences

    Energy Technology Data Exchange (ETDEWEB)

    Jerez, Silvia [Area de Toxicologia, Facultad de Veterinaria, Universidad de Murcia, Campus de Espinardo, 30100 Murcia (Spain); Motas, Miguel, E-mail: motas@um.es [Area de Toxicologia, Facultad de Veterinaria, Universidad de Murcia, Campus de Espinardo, 30100 Murcia (Spain); Palacios, Maria Jose; Valera, Francisco [Departamento de Ecologia Funcional y Evolutiva, Estacion Experimental de Zonas Aridas, CSIC, Carretera de Sacramento s/n, 04120 La Canada de San Urbano, Almeria (Spain); Cuervo, Jose Javier; Barbosa, Andres [Departamento de Ecologia Funcional y Evolutiva, Estacion Experimental de Zonas Aridas, CSIC, Carretera de Sacramento s/n, 04120 La Canada de San Urbano, Almeria (Spain); Departamento de Ecologia Evolutiva, Museo Nacional de Ciencias Naturales, CSIC, C/Jose Gutierrez Abascal 2, 28006 Madrid (Spain)

    2011-10-15

    Antarctica is often considered as one of the last pristine regions, but it could be affected by pollution at global and local scale. Concentrations of Al, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Cd and Pb were determinated by ICP-MS in feathers (n = 207 individuals) of gentoo, chinstrap and Adelie penguin collected in 8 locations throughout the Antarctic Peninsula (2006-2007). The highest levels of several elements were found in samples from King George Island (8.08, 20.29 and 1.76 {mu}g g{sup -1} dw for Cr, Cu and Pb, respectively) and Deception Island (203.13, 3.26 and 164.26 {mu}g g{sup -1} dw for Al, Mn and Fe, respectively), where probably human activities and large-scale transport of pollutants contribute to increase metal levels. Concentrations of Cr, Mn, Cu, Se or Pb, which are similar to others found in different regions of the world, show that some areas in Antarctica are not utterly pristine. - Highlights: > We study levels of trace elements in feathers of Antarctic penguins. > Eight different rookeries throughout the Antarctic Peninsula were sampled. > Interspecific (gentoo, chinstrap, Adelie) and geographical differences were tested. > Relatively high metal levels were found in areas with major human presence. > Penguin feather can be useful for metals monitoring in the Antarctic environment. - Trace element levels in feathers of three penguin species from the Antarctic Peninsula indicate the presence of pollution in certain locations.

  2. Concentration of trace elements in feathers of three Antarctic penguins: Geographical and interspecific differences

    International Nuclear Information System (INIS)

    Jerez, Silvia; Motas, Miguel; Palacios, Maria Jose; Valera, Francisco; Cuervo, Jose Javier; Barbosa, Andres

    2011-01-01

    Antarctica is often considered as one of the last pristine regions, but it could be affected by pollution at global and local scale. Concentrations of Al, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Cd and Pb were determinated by ICP-MS in feathers (n = 207 individuals) of gentoo, chinstrap and Adelie penguin collected in 8 locations throughout the Antarctic Peninsula (2006-2007). The highest levels of several elements were found in samples from King George Island (8.08, 20.29 and 1.76 μg g -1 dw for Cr, Cu and Pb, respectively) and Deception Island (203.13, 3.26 and 164.26 μg g -1 dw for Al, Mn and Fe, respectively), where probably human activities and large-scale transport of pollutants contribute to increase metal levels. Concentrations of Cr, Mn, Cu, Se or Pb, which are similar to others found in different regions of the world, show that some areas in Antarctica are not utterly pristine. - Highlights: → We study levels of trace elements in feathers of Antarctic penguins. → Eight different rookeries throughout the Antarctic Peninsula were sampled. → Interspecific (gentoo, chinstrap, Adelie) and geographical differences were tested. → Relatively high metal levels were found in areas with major human presence. → Penguin feather can be useful for metals monitoring in the Antarctic environment. - Trace element levels in feathers of three penguin species from the Antarctic Peninsula indicate the presence of pollution in certain locations.

  3. [Trace elements of bone tumors].

    Science.gov (United States)

    Kalashnikov, V M; Zaĭchik, V E; Bizer, V A

    1983-01-01

    Due to activation analysis involving the use of neutrons from a nuclear reactor, the concentrations of 11 trace elements: scandium, iron, cobalt, mercury, rubidium, selenium, silver, antimony, chrome, zinc and terbium in intact bone and skeletal tumors were measured. 76 specimens of bioptates and resected material of operations for bone tumors and 10 specimens of normal bone tissue obtained in autopsies of cases of sudden death were examined. The concentrations of trace elements and their dispersion patterns in tumor tissue were found to be significantly higher than those in normal bone tissue. Also, the concentrations of some trace elements in tumor differed significantly from those in normal tissue; moreover, they were found to depend on the type and histogenesis of the neoplasm.

  4. Trace Metal Concentrations in Commercially Important Fishes from ...

    African Journals Online (AJOL)

    komla

    Some trace metals such as zinc and copper are important in small quantities for ...... Cameroon: Institut de recherches meddicales et d'etudes des plantes edicinales, ... Determination of Total Cadmium, Zinc, Lead, Copper in Selected Marine ...

  5. Clean laboratories and clean rooms for analysis of radionuclides and trace elements

    International Nuclear Information System (INIS)

    2003-01-01

    requirements are summarized of clean laboratory environments, for construction materials as well as for materials used during routine analysis, maintenance, and pitfalls in the analysis of radionuclides and elements at trace- and ultra trace levels. Current methodologies and practices are described for planning the installation of a clean environment as well as protocols for maximizing the benefit-to-cost ratio and for achieving QA/QC. Special emphasis is given to the analysis of radionuclides, and measurement of trace, minor and major elements using nuclear and related analytical techniques such as NAA and XRF. Also included are papers contributed by experts from India, the Netherlands, the United States of America and the IAEA Laboratories, Seibersdorf

  6. Ultra-sensitive speciation analysis of mercury by CE-ICP-MS together with field-amplified sample stacking injection and dispersive solid-phase extraction.

    Science.gov (United States)

    Chen, YiQuan; Cheng, Xian; Mo, Fan; Huang, LiMei; Wu, Zujian; Wu, Yongning; Xu, LiangJun; Fu, FengFu

    2016-04-01

    A simple dispersive solid-phase extraction (DSPE) used to extract and preconcentrate ultra-trace MeHg, EtHg and Hg(2+) from water sample, and a sensitive method for the simultaneous analysis of MeHg, EtHg and Hg(2+) by using capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICP-MS) with field-amplified sample stacking injection (FASI) were first reported in this study. The DSPE used thiol cotton particles as adsorbent, and is simple and effective. It can be used to extract and preconcentrate ultra-trace mercury compounds in water samples within 30 min with a satisfied recovery and no mercury species alteration during the process. The FASI enhanced the sensitivity of CE-ICP-MS with 25-fold, 29-fold and 27-fold for MeHg, EtHg and Hg(2+) , respectively. Using FASI-CE-ICP-MS together with DSPE, we have successfully determined ultra-trace MeHg, EtHg and Hg(2+) in tap water with a limits of quantification (LOQs) of 0.26-0.45 pg/mL, an RSD (n = 3) mercury. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Sampling strategy and analysis of trace element concentrations by inductively coupled plasma mass spectrometry on medieval human bones--the concept of chemical life history.

    Science.gov (United States)

    Skytte, Lilian; Rasmussen, Kaare Lund

    2013-07-30

    Medieval human bones have the potential to reveal diet, mobility and treatment of diseases in the past. During the last two decades trace element chemistry has been used extensively in archaeometric investigations revealing such data. Many studies have reported the trace element inventory in only one sample from each skeleton - usually from the femur or a tooth. It cannot a priori be assumed that all bones or teeth in a skeleton will have the same trace element concentrations. Six different bone and teeth samples from each individual were carefully decontaminated by mechanical means. Following dissolution of ca. 20 mg sample in nitric acid and hydrogen peroxide the assays were performed using inductively coupled plasma mass spectrometry (ICPMS) with quadropole detection. We describe the precise sampling technique as well as the analytical methods and parameters used for the ICPMS analysis. The places of sampling in the human skeleton did exhibit varying trace element concentrations. Although the samples are contaminated by Fe, Mn and Al from the surrounding soil where the bones have been residing for more than 500 years, other trace elements are intact within the bones. It is shown that the elemental ratios Sr/Ca and Ba/Ca can be used as indicators of provenance. The differences in trace element concentrations can be interpreted as indications of varying diet and provenance as a function of time in the life of the individual - a concept which can be termed chemical life history. A few examples of the results of such analyses are shown, which contains information about provenance and diagenesis. Copyright © 2013 John Wiley & Sons, Ltd.

  8. Effect of sildenafil citrate (Viagra®) on trace element concentration in serum and brain of rats.

    Science.gov (United States)

    Fayed, Abdel-Hasseb A; Gad, Shereen B

    2011-12-01

    As a vasodilator with good hemodynamic effects, sildenafil has been successfully used in the treatment of patients with pulmonary hypertension and cardiovascular diseases. By selectively inhibiting phosphodiestrase type 5 (PDE-5) and thus effectively reducing the breakdown of c GMP, sildenafil administration can markedly improve the erectile dysfunction. Sildenafil also elevates localized cerebral blood flow in rat brain. The objective of the present study was to investigate the effect of sildenafil on the level of trace elements (Zinc (Zn), copper (Cu), iron (Fe), selenium (Se), cobalt (Co), and chromium (Cr)) in blood and brain of rats. Sixteen male albino rats weighing 180-200 g were divided into two groups (8 rats/group). Sildenafil (Viagra, Pfizer Inc.) was dissolved in saline and administered at a dose of 10mg/kg i.p. (0.5 ml volume) to rats in the treated group every 72 h for 12 injections. Rats in the control group were administered the same volume of saline as in treated group. All rats were sacrificed 24h after the last injection. Blood samples were collected and serum was separated and stored at -20°C. Brains were dissected and stored frozen until analysis. Trace elements concentrations were determined by flame emission atomic absorption spectrophotometer. Results showed that sildenafil injection significantly (P<0.05) increased serum and brain Se and Cu concentrations. Moreover, sildenafil increased the Cr concentration in the brain tissue. It was concluded that sildenafil citrate administration increased serum Se and Cu as well as, increased brain Se, Cu, and Cr concentrations in rats. Copyright © 2011 Elsevier GmbH. All rights reserved.

  9. On the Nature of Ultra-faint Dwarf Galaxy Candidates. II. The Case of Cetus II

    Science.gov (United States)

    Conn, Blair C.; Jerjen, Helmut; Kim, Dongwon; Schirmer, Mischa

    2018-04-01

    We obtained deep Gemini GMOS-S g, r photometry of the ultra-faint dwarf galaxy candidate Cetus II with the aim of providing stronger constraints on its size, luminosity, and stellar population. Cetus II is an important object in the size–luminosity plane, as it occupies the transition zone between dwarf galaxies and star clusters. All known objects smaller than Cetus II (r h ∼ 20 pc) are reported to be star clusters, while most larger objects are likely dwarf galaxies. We found a prominent excess of main-sequence stars in the color–magnitude diagram of Cetus II, best described by a single stellar population with an age of 11.2 Gyr, metallicity of [Fe/H] = ‑1.28 dex, an [α/Fe] = 0.0 dex at a heliocentric distance of 26.3 ± 1.2 kpc. As well as being spatially located within the Sagittarius dwarf tidal stream, these properties are well matched to the Sagittarius galaxy’s Population B stars. Interestingly, like our recent findings on the ultra-faint dwarf galaxy candidate Tucana V, the stellar field in the direction of Cetus II shows no evidence of a concentrated overdensity despite tracing the main sequence for over six magnitudes. These results strongly support the picture that Cetus II is not an ultra-faint stellar system in the Milky Way halo, but made up of stars from the Sagittarius tidal stream.

  10. How healthy is urban horticulture in high traffic areas? Trace metal concentrations in vegetable crops from plantings within inner city neighbourhoods in Berlin, Germany

    International Nuclear Information System (INIS)

    Säumel, Ina; Kotsyuk, Iryna; Hölscher, Marie; Lenkereit, Claudia; Weber, Frauke; Kowarik, Ingo

    2012-01-01

    Food production by urban dwellers is of growing importance in developing and developed countries. Urban horticulture is associated with health risks as crops in urban settings are generally exposed to higher levels of pollutants than those in rural areas. We determined the concentration of trace metals in the biomass of different horticultural crops grown in the inner city of Berlin, Germany, and analysed how the local setting shaped the concentration patterns. We revealed significant differences in trace metal concentrations depending on local traffic, crop species, planting style and building structures, but not on vegetable type. Higher overall traffic burden increased trace metal content in the biomass. The presence of buildings and large masses of vegetation as barriers between crops and roads reduced trace metal content in the biomass. Based on this we discuss consequences for urban horticulture, risk assessment, and planting and monitoring guidelines for cultivation and consumption of crops. - Highlights: ► Traffic-related pollutant deposition as important pathway for crop contamination. ► Heavy metal content often over EU standards for lead concentration in food crops. ► ‘Grow your own’ food in inner cities not always ‘healthier’ than supermarket products. ► No support for generalisations of crops as ‘risky high’ or ‘safe low’ accumulators. - Higher overall traffic burden increased, while the presence of buildings and large masses of vegetation as barriers between crops and roads reduced heavy metal content in crop biomass.

  11. Concentration and subcellular distribution of trace elements in liver of small cetaceans incidentally caught along the Brazilian coast

    Energy Technology Data Exchange (ETDEWEB)

    Kunito, Takashi; Nakamura, Shinji; Ikemoto, Tokutaka; Anan, Yasumi; Kubota, Reiji; Tanabe, Shinsuke; Rosas, Fernando C.W.; Fillmann, Gilberto; Readman, James W

    2004-10-01

    Concentrations of trace elements (V, Cr, Mn, Fe, Co, Cu, Zn, Ga, As, Se, Rb, Sr, Mo, Ag, Cd, Sb, Cs, Ba, T-Hg, Org-Hg, Tl and Pb) were determined in liver samples of estuarine dolphin (Sotalia guianensis; n=20), Franciscana dolphin (Pontoporia blainvillei; n=23), Atlantic spotted dolphin (Stenella frontalis; n=2), common dolphin (Delphinus capensis; n=1) and striped dolphin (Stenella coeruleoalba; n=1) incidentally caught along the coast of Sao Paulo State and Parana State, Brazil, from 1997 to 1999. The hepatic concentrations of trace elements in the Brazilian cetaceans were comparable to the data available in literature on marine mammals from Northern Hemisphere. Concentrations of V, Se, Mo, Cd, T-Hg and Org-Hg increased with increasing age in liver of both estuarine and Franciscana dolphins. Very high concentrations of Cu (range, 262-1970 {mu}g/g dry wt.) and Zn (range, 242-369 {mu}g/g dry wt.) were observed in liver of sucklings of estuarine dolphin. Hepatic concentrations of V, Se, T-Hg, Org-Hg and Pb were significantly higher in estuarine dolphin, whereas Franciscana dolphin showed higher concentrations of Mn, Co, As and Rb. Ratio of Org-Hg to T-Hg in liver was significantly higher in Franciscana dolphin than estuarine dolphin, suggesting that demethylation ability of methyl Hg might be lower in liver of Franciscana than estuarine dolphins. High hepatic concentrations of Ag were found in some specimens of Franciscana dolphin (maximum, 20 {mu}g/g dry wt.), and 17% of Franciscana showed higher concentrations of Ag than Hg. These samples with high Ag concentration also exhibited elevated hepatic Se concentration, implying that Ag might be detoxified by Se in the liver. Higher correlation coefficient between (Hg + 0.5 Ag) and Se than between Hg and Se and the large distribution of Ag in non-soluble fraction in nuclear and mitochondrial fraction of the liver also suggests that Ag might be detoxified by Se via formation of Ag{sub 2}Se in the liver of Franciscana

  12. Concentration and subcellular distribution of trace elements in liver of small cetaceans incidentally caught along the Brazilian coast

    International Nuclear Information System (INIS)

    Kunito, Takashi; Nakamura, Shinji; Ikemoto, Tokutaka; Anan, Yasumi; Kubota, Reiji; Tanabe, Shinsuke; Rosas, Fernando C.W.; Fillmann, Gilberto; Readman, James W.

    2004-01-01

    Concentrations of trace elements (V, Cr, Mn, Fe, Co, Cu, Zn, Ga, As, Se, Rb, Sr, Mo, Ag, Cd, Sb, Cs, Ba, T-Hg, Org-Hg, Tl and Pb) were determined in liver samples of estuarine dolphin (Sotalia guianensis; n=20), Franciscana dolphin (Pontoporia blainvillei; n=23), Atlantic spotted dolphin (Stenella frontalis; n=2), common dolphin (Delphinus capensis; n=1) and striped dolphin (Stenella coeruleoalba; n=1) incidentally caught along the coast of Sao Paulo State and Parana State, Brazil, from 1997 to 1999. The hepatic concentrations of trace elements in the Brazilian cetaceans were comparable to the data available in literature on marine mammals from Northern Hemisphere. Concentrations of V, Se, Mo, Cd, T-Hg and Org-Hg increased with increasing age in liver of both estuarine and Franciscana dolphins. Very high concentrations of Cu (range, 262-1970 μg/g dry wt.) and Zn (range, 242-369 μg/g dry wt.) were observed in liver of sucklings of estuarine dolphin. Hepatic concentrations of V, Se, T-Hg, Org-Hg and Pb were significantly higher in estuarine dolphin, whereas Franciscana dolphin showed higher concentrations of Mn, Co, As and Rb. Ratio of Org-Hg to T-Hg in liver was significantly higher in Franciscana dolphin than estuarine dolphin, suggesting that demethylation ability of methyl Hg might be lower in liver of Franciscana than estuarine dolphins. High hepatic concentrations of Ag were found in some specimens of Franciscana dolphin (maximum, 20 μg/g dry wt.), and 17% of Franciscana showed higher concentrations of Ag than Hg. These samples with high Ag concentration also exhibited elevated hepatic Se concentration, implying that Ag might be detoxified by Se in the liver. Higher correlation coefficient between (Hg + 0.5 Ag) and Se than between Hg and Se and the large distribution of Ag in non-soluble fraction in nuclear and mitochondrial fraction of the liver also suggests that Ag might be detoxified by Se via formation of Ag 2 Se in the liver of Franciscana dolphin

  13. Determination of Ultra-trace Rhodium in Water Samples by Graphite Furnace Atomic Absorption Spectrometry after Cloud Point Extraction Using 2-(5-Iodo-2-Pyridylazo)-5-Dimethylaminoaniline as a Chelating Agent.

    Science.gov (United States)

    Han, Quan; Huo, Yanyan; Wu, Jiangyan; He, Yaping; Yang, Xiaohui; Yang, Longhu

    2017-03-24

    A highly sensitive method based on cloud point extraction (CPE) separation/preconcentration and graphite furnace atomic absorption spectrometry (GFAAS) detection has been developed for the determination of ultra-trace amounts of rhodium in water samples. A new reagent, 2-(5-iodo-2-pyridylazo)-5-dimethylaminoaniline (5-I-PADMA), was used as the chelating agent and the nonionic surfactant TritonX-114 was chosen as extractant. In a HAc-NaAc buffer solution at pH 5.5, Rh(III) reacts with 5-I-PADMA to form a stable chelate by heating in a boiling water bath for 10 min. Subsequently, the chelate is extracted into the surfactant phase and separated from bulk water. The factors affecting CPE were investigated. Under the optimized conditions, the calibration graph was linear in the range of 0.1-6.0 ng/mL, the detection limit was 0.023 ng/mL for rhodium and relative standard deviation was 3.67% ( c = 1.0 ng/mL, n = 11).The method has been applied to the determination of trace rhodium in water samples with satisfactory results.

  14. LASER SPECTROSCOPY AND TRACE ELEMENT ANALYSIS Chapter from the Energy and Environment Division Annual Report 1980

    Energy Technology Data Exchange (ETDEWEB)

    Various, Authors

    1981-05-01

    In order to control pollutants resulting from energy production and utilization, adequate methods are required for monitoring the level of various substances often present at low concentrations. The Energy and Environment Division Applied Research in Laser Spectroscopy & Analytical Techniques Program is directed toward meeting these needs, Emphasis is on the development of physical methods, as opposed to conventional chemical analysis techniques. The advantages, now widely recognized, include ultra-high sensitivity coupled with minimal sample preparation. In some instances physical methods provide multi-parameter measurements which often provide the only means of achiev·ing the sensitivity necessary for the detection of trace contaminants. Work is reported in these areas: APPLIED PHYSICS AND LASER SPECTROSCOPY RESEARCH; MICROPROCESSOR CONTROLLER ANODIC STRIPPING VOLTAMETER FOR TRACE METALS ANALYSIS IN WATER; THE SURVEY OF INSTRUMENTATION FOR ENVIRONMENTAL MONITORING; THE POSSIBLE CHRONDRITIC NATURE OF THE DANISH CRETACEOUS~TERTIARY BOUNDARY; IMPROVEMENT OF THE SENSITIVITY AND PRECISION OF NEUTRON ACTIVATION ANALYSIS OF SOME ELEMENTS IN PLANKTON AND PLANKTONIC FISH; and SOURCES OF SOME SECONDARILY WORKED OBSIDIAN ARTIFACTS FROM TIKAL, GUATEMALA.

  15. The significance of pancreatic juice trace-element concentration in chronic pancreatitis

    International Nuclear Information System (INIS)

    Persigehl, M.; Loeffler, A.; Hoeck, A.

    1979-01-01

    The diagnosis of exocrine pancreas insufficiency in patients with chronic pancreatitis is still not easy. The best-suited method to confirm the diagnosis seems to be the secretin pancreozymin test (SPT). As previous results have shown, the determination of trace elements in the pancreatic juice can improve the diagnostic value of the SPT. During the SPT, the concentrations of Zn, Fe, Rb, Co, Cr, Se, Sb, Cs, Sc and Ag were measured in the duodenal aspirate of 50 patients by instrumental neutron activation analysis. Of the 50 patients, 24 suffered from pancreatic insufficiency in chronic pancreatitis and 26 had no signs of pancreatic insufficiency. Only the concentration of zinc differed significantly in the two groups; the other elements showed a similar behaviour. In patients without disease of the exocrine pancreas the zinc content of the pancreatic juice during the SPT ws 0.46+-0.13μg/ml, whereas in patients with pancreatic insufficiency it was only 0.18+-0.07μg/ml. The corresponding output was 171+-49.3μg zinc in controls and 41+-17.4μg in patients. After stimulation with pancreozymin the concentrations of zinc increased in normal patients to 1.13+-0.14μg/ml and to 0.22+-0.12μg/ml in patients with pancreatic insufficiency. The data demonstrate that the measurement of zinc in the duodenal juice during the SPT improves the diagnostic value of the test and that zinc should also be determined in doubtful cases of pancreatic insufficiency. (author)

  16. Trace analysis of actinides in the environment using resonance ionization mass spectrometry

    International Nuclear Information System (INIS)

    Raeder, Sebastian

    2011-01-01

    In this work the resonant ionization of neutral atoms using laser radiation was applied and optimized for ultra-trace analysis of the actinides thorium, uranium, neptunium and plutonium. The sensitive detection of these actinides is a challange for the monitoring and quantification of radioactive releases from nuclear facilities. Using resonance ionization spectroscopy combined with a newly developed quadrupole-mass-spectrometer, numerous energy levels in the atomic structure of these actinides could be identified. With this knowledge efficient excitation schemes for the mentioned actinides could be identified and characterised. The applied in-source-ionization ensures for a high detection efficiency due to the good overlap of laser radiation with the atomic beam and allows therefore for a low sample consumption which is required for the analysis of radio nuclides. The selective excitation processes in the resonant ionization method supresses unwanted contaminations and was optimized for analytical detection of ultra-trace amounts in environmental samples as well as for determination of isotopic compositions. The efficient in-source-ionization combined with high power pulsed laser radiation allows for detections efficiency up to 1%. For plutonium detection limits in the range of 10 4 -10 5 atoms could be demonstrated for synthetic samples as well as for first environmental samples. The usage of narrow bandwidth continuous wave lasers in combination with a transversal overlap of the laser radiation and the free propagating atomic beam enable for resolving individual isotopic shifts of the resonant transitions. This results in a high selectivity against dominant neighboring isotopes but with a significant loss in detection efficiency. For the ultra-trace isotope 236 U a detection limit down to 10 -9 for the isotope ratio N ( 236 U)/N ( 238 U) could be determined.

  17. Impulse radio ultra wideband wireless transmission of dopamine concentration levels recorded by fast-scan cyclic voltammetry.

    Science.gov (United States)

    Ebrazeh, Ali; Bozorgzadeh, Bardia; Mohseni, Pedram

    2015-01-01

    This paper demonstrates the feasibility of utilizing impulse radio ultra wideband (IR-UWB) signaling technique for reliable, wireless transmission of dopamine concentration levels recorded by fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) to address the problem of elevated data rates in high-channel-count neurochemical monitoring. Utilizing an FSCV-sensing chip fabricated in AMS 0.35μm 2P/4M CMOS, a 3-5-GHz, IR-UWB transceiver (TRX) chip fabricated in TSMC 90nm 1P/9M RF CMOS, and two off-chip, miniature, UWB antennae, wireless transfer of pseudo-random binary sequence (PRBS) data at 50Mbps over a distance of wireless transmission of dopamine concentration levels prerecorded with FSCV at a CFM during flow injection analysis (FIA) is also demonstrated with transmitter (TX) power dissipation of only ~4.4μW from 1.2V, representing two orders of magnitude reduction in TX power consumption compared to that of a conventional frequency-shift-keyed (FSK) link operating at ~433MHz.

  18. Species- and stage-specific differences in trace element tissue concentrations in amphibians: implications for the disposal of coal-combustion wastes

    Energy Technology Data Exchange (ETDEWEB)

    Roe, J.H.; Hopkins, W.A.; Jackson, B.P. [University of Georgia, Aiken, SC (US)

    2005-07-01

    Information on species- and stage-specific patterns of contaminant accumulation is generally lacking for amphibians, yet such information could provide valuable knowledge on how amphibians interact with contaminants. We assessed concentrations of As, Cd, Cu, Ni, Pb, Se, Sr, and Zn in whole bodies of larval, recently metamorphosed, and adult life stages in Bufo terrestris and Rana sphenocephala from a site that currently receives coal combustion waste (CCW) discharge, a site where CCW was formerly discharged that has undergone natural attenuation for 30 years, and a nearby reference site. For the majority of elements (As, Cd, Cu, Ni, Pb, Zn), concentrations were highest in larvae, but Se and Sr concentrations remained elevated in later life stages, likely because these elements are S and Ca analogs, respectively, and are thus retained throughout structural changes during metamorphosis. Element concentrations were generally higher in B. terrestris than in R. sphenocephala. Concentrations of As, Se, and Sr were up to 11-35 times higher in metamorphs emigrating from CCW-polluted wetlands compared to unpolluted wetlands, suggesting metamorphosed amphibians can transport trace elements from aquatic disposal basins to nearby uncontaminated terrestrial habitats. In addition, anurans utilizing naturally revegetated sites up to 30 years after CCW disposal ceases are exposed to trace elements, although to a lesser degree than sites where CCW is currently discharged.

  19. Trace metals concentration assessment in urban particulate matter ...

    African Journals Online (AJOL)

    This study was conducted to investigate the distribution and correlation of selected trace elements (Ca, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, and Zn) in Yenagoa, Bayelsa State and its environs. Air particulate matter was collected gravimetrically at five stations (using a high volume portable SKC air check MTXSidekickair sampler ...

  20. Trace Elements in Teeth by ICPMS

    International Nuclear Information System (INIS)

    Zahran, N.F.; Helal, A.I.; Amr, M.A.; Amr, M.A.; Al-saad, K.A.

    2008-01-01

    Teeth are reported to be suitable indicators of trace element exposure from environment and nutritional status. Inductively coupled plasma mass spectrometry (ICP-MS) is used to compare the trace element content of children's primary teeth and adult teeth. Primary teeth are collected from 28 children and 42 adult from non-industrial City. The data are assessed statistically using t-tests. The adult teeth contained significantly greater concentrations of Na, Mg, Al, Fe, Ni, Cu, Sr, Cd, Ba, Pb and U and significantly less Mn, Co, As, Se, Mo and Bi than the children teeth. Additional measurements on adult teeth pulps are performed. Comparison between trace element concentrations in health and caries teeth pulps show that the mean concentrations of Na, Al, K, Cr, Mn, Co, Cu, Zn, Mo, Ag, Bi and U are lower in caries than healthy teeth pulps. On the other hand, the mean concentrations of Mg, Cd and Pb are higher in caries samples than healthy teeth pulps

  1. Is trace element concentration correlated to parasite abundance? A case study in a population of the green frog Pelophylax synkl. hispanicus from the Neto River (Calabria, southern Italy).

    Science.gov (United States)

    De Donato, Carlo; Barca, Donatella; Milazzo, Concetta; Santoro, Raffaella; Giglio, Gianni; Tripepi, Sandro; Sperone, Emilio

    2017-06-01

    Bioaccumulation of 13 trace elements in the livers of 38 Pelophylax sinkl. hispanicus (Ranidae) and its helminth communities were studied and compared among three sites, each with a different degree of pollution along River Neto (south Italy) during September, 2014. Trace element concentrations in water and liver were measured using inductively coupled plasma mass spectrometry. For most elements, the highest concentration was recorded in the frogs inhabiting the third site, the one with the highest degree of pollution. The trend of trace element concentration in the liver can be represented as follows: Cu > Zn > Mn > Se > Cr. Concentrations of some elements in water and liver samples were significantly different among the three sites and this is evidenced by the bioaccumulation in the frogs. Four species of helminths, all belonging to Nematoda, were found: Rhabdias sp., Oswaldocruzia filiformis (Goeze, 1782), Cosmocerca ornata (Dujarden, 1845), Seuratascaris numidica (Seurat, 1917). The parasite survey presents an important difference of prevalence and average number of helminths in frogs between the three sites. Correlating parasitological and ecotoxicological data showed a strong positive correlation between prevalence and number of parasites with some trace elements such as Mn, Co, Ni, As, Se, and Cd.

  2. Using the ion microprobe mass analyser for trace element analysis

    International Nuclear Information System (INIS)

    Schilling, J.H.

    1978-01-01

    Most techniques for the analysis of trace elements are capable of determining the concentrations in a bulk sample or solution, but without reflecting their distribution. In a bulk analysis therefore elements which occur in high concentration in a few precipitates would still be considered trace elements even though their local concentration greatly exceed the normally accepted trace elements concentration limit. Anomalous distribution is also shown by an oxide layer, a few hundred Angstrom thick, on an aluminium sample. A low oxide concentration would be reported if it were included in the bulk analysis, which contradicts the high surface concentration. The importance of a knowledge of the trace element distribution is therefore demonstrated. Distributional trace element analysis can be carried out using the ion microprobe mass analyser (IMMA). Since the analytical technique used in this instrument, namely secondary ion mass spectrometry (SIMS), is not universally appreciated, the instrument and its features will be described briefly followed by a discussion of quantitative analysis and the related subjects of detection limit and sample consumption. Finally, a few examples of the use of the instrument are given

  3. A compilation of silicon, rare earth element and twenty-one other trace element concentrations in the natural river water reference material SLRS-5 (NRC-CNRC)

    International Nuclear Information System (INIS)

    Yeghicheyan, Delphine; Cloquet, Christophe; Bossy, Cecile; Bouhnik Le Coz, Martine; Douchet, Chantal; Granier, Guy; Heimburger, Alexie; Losno, Remi; Lacan, Francois; Labatut, Marie; Pradoux, Catherine; Lanzanova, Aurelie; Candaudap, Frederic; Chmeleff, Jerome; Rousseau, Tristan C.C.; Seidel, Jean-Luc; Delpoux, Sophie; Tharaud, Mickael; Sivry, Yann; Sonke, Jeroen E.

    2013-01-01

    The natural river water certified reference material SLRS-5 (NRC-CNRC) was routinely analysed in this study for major and trace elements by ten French laboratories. Most of the measurements were made using ICP-MS. Because no certified values are assigned by NRC-CNRC for silicon and 35 trace element concentrations (rare earth elements, Ag, B, Bi, Cs, Ga, Ge, Li, Nb, P, Rb, Rh, Re, S, Sc, Sn, Th, Ti, Tl, W, Y and Zr), or for isotopic ratios, we provide a compilation of the concentrations and related uncertainties obtained by the participating laboratories. Strontium isotopic ratios are also given. (authors)

  4. Trace metal concentrations are higher in cartilage than in bones of scaup and pochard wintering in Poland

    International Nuclear Information System (INIS)

    Kalisinska, Elzbieta; Salicki, Wieslaw; Kavetska, Katarzyna M.; Ligocki, Marek

    2007-01-01

    Bones and cartilage of two species of diving ducks: the scaup Aythya marila (n = 24) and the pochard A. ferina (n = 24) were studied. Scaup is protected in Poland where it spends only the winter, while pochard is a game bird, abundant and breeding in Poland. In winter, the two species form large flocks off the southern coast of the Baltic, particularly in the Szczecin Lagoon where they were collected for this study. The bones and cartilage (trachea) were assayed for concentrations (dry weight-based) of three essential metals: iron (Fe), copper (Cu), and zinc (Zn); concentrations of the two toxic metals: lead (Pb) and cadmium (Cd) were assayed as well. These hard tissues of the two species showed the following order of metal concentrations Zn > Fe > Pb > Cu > Cd. In scaup and pochard bones, the respective geometric mean concentrations of Zn, Fe, Pb, Cu, and Cd were 94.4 and 102.0; 20.2 and 24.7; 6.2 and 9.6; 0.19 and 0.26; 0.114 and 0.162 mg/kg. The levels of all the metals in cartilage (Zn 149.1 and 165.8; Fe 58.4 and 116.3; Pb 10.6 and 14.9; Cu 1.41 and 3.31; Cd 0.144 and 0.175 mg/kg, respectively) were higher than in the bones of A. marila and A. ferina. However, statistically significant differences were found in respect to the essential metals only (Zn, Fe, Cu). The inter-species comparisons showed the two species to differ in their cartilage concentrations of Fe, Cu, Zn, and Cd and in their bone concentrations of Pb and Cd. In each case, the pochard exhibited higher concentrations of metals. This study showed distinct differences between trace element accumulation by two heavily mineralised avian body parts: leg bones (tarsometatarsus) and cartilage (trachea). The results are in agreement with data reported by other workers who analysed trace metals in cartilaginous and bone components of the femoral head in homoiotherm vertebrates, including humans. Therefore it is important that intra- and inter-species comparisons of hard biological components be based on

  5. Influence of subinhibitory concentrations of antimicrobials on hydrophobicity, adherence and ultra-structure of Fusobacterium nucleatum

    Directory of Open Access Journals (Sweden)

    Okamoto Ana C.

    2002-01-01

    Full Text Available Fusobacterium nucleatum is considered a bridge organism between earlier and later colonizers in dental biofilms and a putative periodontopathogen. In Dentistry, antimicrobial agents are used for treatment and control of infectious diseases associated with dental plaque. Antiseptics have been used in association with antibiotics to reduce infections after oral surgeries. In this study, the influence of subinhibitory concentrations (SC of chlorhexidine, triclosan, penicillin G and metronidazole, on hydrophobicity, adherence to oral epithelial cells, and ultra-structure of F. nucleatum was examined. All isolates were susceptible to chlorhexidine, triclosan, and metronidazole; however, most of the isolates were susceptible to penicillin G, and all of them were hydrophilic when grown with or without antimicrobials. Adherence was decreased by all antimicrobials. Results suggest that adherence of F. nucleatum was influenced by adhesins because structures such as fimbries or capsule were not observed by transmission electronic microscope.

  6. Subclinical mastitis (SCM) and proinflammatory cytokines are associated with mineral and trace element concentrations in human breast milk.

    Science.gov (United States)

    Li, Chen; Solomons, Noel W; Scott, Marilyn E; Koski, Kristine G

    2018-03-01

    The possibility that either subclinical mastitis (SCM), an inflammatory condition of the breast, or elevations in breast milk proinflammatory cytokines alter breast milk mineral and trace element composition in humans has not been investigated. In this cross-sectional study, breast milk samples (n=108) were collected from Guatemalan Mam-Mayan mothers at one of three stages of lactation (transitional, early and established), and categorized as SCM (Na:K >0.6) or non-SCM (Na:K ≤0.6). Milk concentrations of 12 minerals (calcium, copper, iron, magnesium, manganese, phosphorus, potassium, rubidium, selenium, sodium, strontium, and zinc) and 4 proinflammatory cytokines (IL-1β, IL-6, IL-8, TNF-α) were measured by inductively coupled plasma mass spectrometry (ICP-MS), Lachat analyzer or Luminex multiplex bead cytokine assay. SCM was more prevalent during transitional (30%) than early (15.6%) and established (8.9%) lactation. Analysis of variance revealed that breast milk minerals differed by stage of lactation and SCM status. Breast milk minerals with the exception of magnesium were lower in established lactation, whereas SCM was associated with higher selenium and lower phosphorus. Regression models that controlled for lactation stage also confirmed that SCM was associated with lower milk phosphorus and higher milk selenium concentrations. Furthermore, cytokine concentrations were independently associated with several mineral concentrations: IL-1β with higher phosphorus and iron, IL-6 with higher calcium, magnesium, copper and manganese, IL-8 with higher calcium and zinc, and TNF-α with lower iron and manganese. We conclude that milk mineral and trace element concentrations are affected not only by the presence of SCM but also by proinflammatory cytokines in breast milk. Copyright © 2017 Elsevier GmbH. All rights reserved.

  7. Changes of trace element concentrations in vegetables during the usual food processing in the household found out by means of activation analysis

    International Nuclear Information System (INIS)

    Schelenz, R.

    1981-01-01

    The influence of processing of various vegetables and potatoes (cleaning, cutting, washing, cooking, steam-cooking) on the concentration of ingestion-physiologically important mineral- and trace elements has been studied by means of instrumental activation analysis. The leaching effects play a less important role in steam-cooking. Than in normal cooking. The most important loss already occurs when preparing the vegetables for cooking. This applies especially also to the essential trace elements; but also toxic elements such as arsenic are greatly reduced during this process. (RB) [de

  8. Substrate use of Pseudovibrio sp. growing in ultra-oligotrophic seawater.

    Directory of Open Access Journals (Sweden)

    Anne Schwedt

    Full Text Available Marine planktonic bacteria often live in habitats with extremely low concentrations of dissolved organic matter (DOM. To study the use of trace amounts of DOM by the facultatively oligotrophic Pseudovibrio sp. FO-BEG1, we investigated the composition of artificial and natural seawater before and after growth. We determined the concentrations of dissolved organic carbon (DOC, total dissolved nitrogen (TDN, free and hydrolysable amino acids, and the molecular composition of DOM by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI FT-ICR-MS. The DOC concentration of the artificial seawater we used for cultivation was 4.4 μmol C L(-1, which was eight times lower compared to the natural oligotrophic seawater we used for parallel experiments (36 μmol C L(-1. During the three-week duration of the experiment, cell numbers increased from 40 cells mL(-1 to 2x10(4 cells mL(-1 in artificial and to 3x10(5 cells mL(-1 in natural seawater. No nitrogen fixation and minor CO2 fixation (< 1% of cellular carbon was observed. Our data show that in both media, amino acids were not the main substrate for growth. Instead, FT-ICR-MS analysis revealed usage of a variety of different dissolved organic molecules, belonging to a wide range of chemical compound groups, also containing nitrogen. The present study shows that marine heterotrophic bacteria are able to proliferate with even lower DOC concentrations than available in natural ultra-oligotrophic seawater, using unexpected organic compounds to fuel their energy, carbon and nitrogen requirements.

  9. Trace element concentration and speciation in selected urban soils in New York City.

    Science.gov (United States)

    Burt, R; Hernandez, L; Shaw, R; Tunstead, R; Ferguson, R; Peaslee, S

    2014-01-01

    A long history of urbanization and industrialization has affected trace elements in New York City (NYC) soils. Selected NYC pedons were analyzed by aqua regia microwave digestion and sequential chemical extraction as follows: water soluble (WS); exchangeable (EX); specifically sorbed/carbonate bound (SS/CAR); oxide-bound (OX); organic/sulfide bound (OM/S). Soils showed a range in properties (e.g., pH 3.9 to 7.4). Sum of total extractable (SUMTE) trace elements was higher in NYC parks compared to Bronx River watershed sites. NYC surface horizons showed higher total extractable (TE) levels compared to US non-anthropogenic soils. TE levels increased over 10 year in some of the relatively undisturbed and mostly wooded park sites. Surface horizons of park sites with long-term anthropogenic inputs showed elevated TE levels vs. subsurface horizons. Conversely, some Bronx River watershed soils showed increased concentrations with depth, reflective of their formation in a thick mantle of construction debris increasing with depth and intermingled with anthrotransported soil materials. Short-range variability was evident in primary pedons and satellite samples (e.g., Pb 253 ± 143 mg/kg). Long-range variability was indicated by PbTE (348 versus 156 mg/kg) and HgTE (1 versus 0.3 mg/kg) concentrations varying several-fold in the same soil but in different geographic locations. Relative predominance of fractions: RES (37 %) > SS/CAR (22 %) > OX (20 %) > OM/S (10 %) > EX (7 %) > WS (4 %). WS and EX fractions were greatest for Hg (7 %) and Cd (14 %), respectively. RES was predominant fraction for Co, Cr, Ni, and Zn (41 to 51 %); SS/CAR for Cd and Pb (40 and 63 %); OM/S for Cu and Hg (36 and 37 %); and OX for As (59 %).

  10. Well-constructed cellulose acetate membranes for forward osmosis: Minimized internal concentration polarization with an ultra-thin selective layer

    KAUST Repository

    Zhang, Sui

    2010-09-01

    The design and engineering of membrane structure that produces low salt leakage and minimized internal concentration polarization (ICP) in forward osmosis (FO) processes have been explored in this work. The fundamentals of phase inversion of cellulose acetate (CA) regarding the formation of an ultra-thin selective layer at the bottom interface of polymer and casting substrate were investigated by using substrates with different hydrophilicity. An in-depth understanding of membrane structure and pore size distribution has been elucidated with field emission scanning electronic microscopy (FESEM) and positron annihilation spectroscopy (PAS). A double dense-layer structure is formed when glass plate is used as the casting substrate and water as the coagulant. The thickness of the ultra-thin bottom layer resulted from hydrophilic-hydrophilic interaction is identified to be around 95nm, while a fully porous, open-cell structure is formed in the middle support layer due to spinodal decomposition. Consequently, the membrane shows low salt leakage with mitigated ICP in the FO process for seawater desalination. The structural parameter (St) of the membrane is analyzed by modeling water flux using the theory that considers both external concentration polarization (ECP) and ICP, and the St value of the double dense-layer membrane is much smaller than those reported in literatures. Furthermore, the effects of an intermediate immersion into a solvent/water mixed bath prior to complete immersion in water on membrane formation have been studied. The resultant membranes may have a single dense layer with an even lower St value. A comparison of fouling behavior in a simple FO-membrane bioreactor (MBR) system is evaluated for these two types of membranes. The double dense-layer membrane shows a less fouling propensity. This study may help pave the way to improve the membrane design for new-generation FO membranes. © 2010 Elsevier B.V.

  11. Ultra-trace determination of Persistent Organic Pollutants in Arctic ice using stir bar sorptive extraction and gas chromatography coupled to mass spectrometry.

    Science.gov (United States)

    Lacorte, S; Quintana, J; Tauler, R; Ventura, F; Tovar-Sánchez, A; Duarte, C M

    2009-12-04

    This study presents the optimization and application of an analytical method based on the use of stir bar sorptive extraction (SBSE) gas chromatography coupled to mass spectrometry (GC-MS) for the ultra-trace analysis of POPs (Persistent Organic Pollutants) in Arctic ice. In a first step, the mass-spectrometry conditions were optimized to quantify 48 compounds (polycyclic aromatic hydrocarbons, brominated diphenyl ethers, chlorinated biphenyls, and organochlorinated pesticides) at the low pg/L level. In a second step, the performance of this analytical method was evaluated to determine POPs in Arctic cores collected during an oceanographic campaign. Using a calibration range from 1 to 1800 pg/L and by adjusting acquisition parameters, limits of detection at the 0.1-99 and 102-891 pg/L for organohalogenated compounds and polycyclic aromatic hydrocarbons, respectively, were obtained by extracting 200 mL of unfiltered ice water. alpha-hexachlorocyclohexane, DDTs, chlorinated biphenyl congeners 28, 101 and 118 and brominated diphenyl ethers congeners 47 and 99 were detected in ice cores at levels between 0.5 to 258 pg/L. We emphasise the advantages and disadvantages of in situ SBSE in comparison with traditional extraction techniques used to analyze POPs in ice.

  12. Tracing discharges of plutonium and technetium from nuclear processing plants by ultra-sensitive accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Fifield, L.K.; Hausladen, P.A.; Cresswell, R.G.; Di Tada, M.L.; Day, J.P.; Carling, R.S.; Oughton, D.H.

    1999-01-01

    Historical discharges of plutonium from the Russian nuclear processing plant at Mayak in the Urals have been traced in sediments, soils and river water using ultra-sensitive detection of plutonium isotopes by accelerator mass spectrometry (AMS). Significant advantages of AMS over other techniques are its very high sensitivity. which is presently ∼10 6 atoms (1 μBq), and its ability to determine the 240 Pu/ 239 Pu ratio. The latter is a sensitive indicator of the source of the plutonium, being very low (1-2%) for weapons grade plutonium, and higher (∼ 20%) for plutonium from civil reactors or fallout from nuclear weapons testing. Since this ratio has changed significantly over the years of discharges from Mayak, a measurement can provide important information about the source of plutonium at a particular location. Similar measurements have been performed on samples from the Kara Sea which contains a graveyard of nuclear submarines from the former Soviet Union. AMS techniques have also been developed for detection of 99 Tc down to levels of a few femtograms. This isotope is one of the most prolific fission products and has a very long half-life of 220 ka. Hundreds of kg have been discharged from the nuclear reprocessing plant at Sellafield in the UK. While there may be public health issues associated with these discharges which can be addressed with AMS, these discharges may also constitute a valuable oceanographic tracer experiment in this climatically-important region of the world's oceans. Applications to date have included a human uptake study to assess long-term retention of 99 Tc in the body, and a survey of seaweeds from northern Europe to establish a baseline for a future oceanographic study

  13. Plasma trace metals during total parenteral alimentation.

    Science.gov (United States)

    Solomons, N W; Layden, T J; Rosenberg, I H; Vo-Khactu, K; Sandstead, H H

    1976-06-01

    The plasma concentrations of the trace metals zinc and copper were studied prospectively in 13 patients with gastrointestinal diseases treated with parenteral alimentation (TPA) for periods of from 8 days to 7 1/2 weeks. Plasma copper levels fell rapidly and consistently in all patients, with an overall rate of - 11 mug per 100 ml per week. Zinc concentrations declined in 10 of 13 patients at a more gradual rate. Analysis of the standard parenteral alimentation fluids revealed zinc content equivalent to 50% of the daily requirement and a negligible content of copper. From combined analysis of plasma zinc, hair zinc, and taste acuity, there is evidence that increased utilization or redistribution within the body may effect plasma concentrations in some patients. Neither an increase in urinary excretion nor a primary decrease in plasma binding proteins appeared to be a major factor in lowering plasma trace metal concentrations. These findings indicate that a marked decrease in plasma copper is regular and a decline in plasma zinc is common during TPA using fluids unsupplemented with trace metals. Supplementation of parenteral alimentation fluids with the trace metals zinc and copper is recommended.

  14. Trace Elements in the Sea Surface Microlayer: Results from a Two Year Study in the Florida Keys

    Science.gov (United States)

    Ebling, A. M.; Westrich, J. R.; Lipp, E. K.; Mellett, T.; Buck, K. N.; Landing, W. M.

    2016-02-01

    Natural and anthropogenic aerosols are a significant source of trace elements to oligotrophic ocean surface waters, where they provide episodic pulses of limiting micronutrients for the microbial community. Opportunistic bacteria have been shown to experience rapid growth during deposition events. However, little is known about the fate of trace elements at the air-sea interface, i.e. the sea surface microlayer. It has been hypothesized that dust particles would be retained in the sea surface microlayer long enough to undergo chemical and physical changes that would affect the bioavailability of trace elements. In this study, aerosols, sea surface microlayer, and underlying water column samples were collected in the Florida Keys in July 2014 and May 2015 at various locations and analyzed for a suite of dissolved and particulate trace elements. Sea surface microlayer samples ( 50 μm) were collected using a cylinder of ultra-pure quartz glass; a novel adaptation of the glass plate technique. Sampling sites ranged from a more pristine environment approximately ten kilometers offshore to a more anthropogenic environment within a shallow bay a few hundred meters offshore. While it was clear from the results that dust deposition events played a large role in the chemical composition of the sea surface microlayer (elevated concentrations in dissolved and particulate trace elements associated with dust deposition), the location where the samples were collected also had a large impact on the sea surface microlayer as well as the underlying water column. The results were compared with other parameters analyzed such as Vibrio cultures as well as iron speciation, providing an important step towards our goal of understanding of the fate of trace elements in the sea surface microlayer as well as the specific effects of aeolian dust deposition on heterotrophic microbes in the upper ocean.

  15. Probing Trace-elements in Bitumen by Neutron Activation Analysis

    NARCIS (Netherlands)

    Nahar, S.N.; Schmets, A.J.M.; Scarpas, Athanasios

    Trace elements and their concentrations play an important role in both chemical and physical properties of bitumen. Instrumental Neutron Activation Analysis (INAA) has been applied to determine the concentration of trace elements in bitumen. This method requires irradiation of the material with

  16. Space-resolved analysis of trace elements in fresh vegetables using ultraviolet nanosecond laser-induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Juve, Vincent; Portelli, Richard; Boueri, Myriam; Baudelet, Matthieu; Yu Jin

    2008-01-01

    Laser-induced breakdown spectroscopy (LIBS) has been applied to analyze trace elements contained in fresh vegetables. A quadrupled Nd:YAG laser is used in the experiments for ablation. Analyzed samples come from local markets and represent frequently consumed vegetables. For a typical root vegetable, such as potato, spectral analysis of the plasma emission reveals more than 400 lines emitted by 27 elements and 2 molecules, C 2 and CN. Among these species, one can find trace as well as ultra-trace elements. A space-resolved analysis of several trace elements with strong emissions is then applied to typical root, stem and fruit vegetables. The results from this study demonstrate the potential of an interesting tool for botanical and agricultural studies as well for food quality/safety and environment pollution assessment and control

  17. Sensitivity enhancement by chromatographic peak concentration with ultra-high performance liquid chromatography-nuclear magnetic resonance spectroscopy for minor impurity analysis.

    Science.gov (United States)

    Tokunaga, Takashi; Akagi, Ken-Ichi; Okamoto, Masahiko

    2017-07-28

    High performance liquid chromatography can be coupled with nuclear magnetic resonance (NMR) spectroscopy to give a powerful analytical method known as liquid chromatography-nuclear magnetic resonance (LC-NMR) spectroscopy, which can be used to determine the chemical structures of the components of complex mixtures. However, intrinsic limitations in the sensitivity of NMR spectroscopy have restricted the scope of this procedure, and resolving these limitations remains a critical problem for analysis. In this study, we coupled ultra-high performance liquid chromatography (UHPLC) with NMR to give a simple and versatile analytical method with higher sensitivity than conventional LC-NMR. UHPLC separation enabled the concentration of individual peaks to give a volume similar to that of the NMR flow cell, thereby maximizing the sensitivity to the theoretical upper limit. The UHPLC concentration of compound peaks present at typical impurity levels (5.0-13.1 nmol) in a mixture led to at most three-fold increase in the signal-to-noise ratio compared with LC-NMR. Furthermore, we demonstrated the use of UHPLC-NMR for obtaining structural information of a minor impurity in a reaction mixture in actual laboratory-scale development of a synthetic process. Using UHPLC-NMR, the experimental run times for chromatography and NMR were greatly reduced compared with LC-NMR. UHPLC-NMR successfully overcomes the difficulties associated with analyses of minor components in a complex mixture by LC-NMR, which are problematic even when an ultra-high field magnet and cryogenic probe are used. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. ULTRA-LIGHTWEIGHT CEMENT

    International Nuclear Information System (INIS)

    Fred Sabins

    2001-01-01

    The objective of this project is to develop an improved ultra-lightweight cement using ultra-lightweight hollow glass spheres (ULHS). Work reported herein addresses Task 1: Assess Ultra-Lightweight Cementing Issues, Task 2: Review Russian Ultra-Lightweight Cement Literature, Task 3: Test Ultra-Lightweight Cements, and Task 8: Develop Field ULHS Cement Blending and Mixing Techniques. Results reported this quarter include: preliminary findings from a literature review focusing on problems associated with ultra-lightweight cements; summary of pertinent information from Russian ultra-lightweight cement literature review; laboratory tests comparing ULHS slurries to foamed slurries and sodium silicate slurries for two different applications; and initial laboratory studies with ULHS in preparation for a field job

  19. DISTRIBUTION OF TRACE ELEMENTS IN MUSCLE AND ORGANS ...

    African Journals Online (AJOL)

    a

    revealed organ specific distribution of trace metals in Tilapia, which has been discussed .... The concentrations of copper (Table 2) varied from 1.68–4.95 in muscle, .... The lead concentrations in muscle and organs of Tilapia from both lakes were comparable. ... A, D and K, trace minerals, and essential fats and amino acids.

  20. Extractable trace elements and sodium in Illinois coal-cleaning wastes: correlation with concentrations in tall fescue

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, B.G.

    1983-07-01

    Trace element concentrations in shoots of tall fescue (Festuca arundinacea Schreb.) were correlated with extractable element concentrations in five southern Illinois coal-cleaning wastes limed to pH 6.5, in a greenhouse study to determine applicability of soil tests to coal-waste evaluation. There was little or no correlation between shoot concentrations of Fe, and Fe extracted from the wastes by dilute acid (r equals 0.60), DTPA at pH 6.4 (r equals 0.47) or DTPA at pH 8.4 (r equals -0.17). The corresponding r values for Mn were 0.94, 0.97, and 0.96; for Zn, 0.96, 0.96, and 0.88; and for Cu, 0.67, 0.90, and 0.88, respectively. Shoot B correlated well with hot water-soluble B(r equals 0.96) and acid-soluble B(r equals 0.91). Correlations for shoot Na were also good with water-soluble Na and acid-soluble Na (r equals 0.96 in both cases). Concentrations of Al, As, Cd, Ni, Pb, and Se in the shoots were well below reported upper critical levels, and similar to concentrations in the grass grown on a silt loam under the same greenhouse conditions. 21 references.

  1. Trace elements in coloured opals using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    McOrist, G D; Smallwood, A [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1997-12-31

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs.

  2. Trace elements in coloured opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1996-01-01

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs

  3. Trace elements in coloured opals using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    McOrist, G.D.; Smallwood, A. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1996-12-31

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs.

  4. Ultratrace determination of arsenic in water samples by electrothermal atomic absorption spectrometry after pre-concentration with Mg-Al-Fe ternary layered double hydroxide nano-sorbent.

    Science.gov (United States)

    Abdolmohammad-Zadeh, Hossein; Jouyban, Abolghasem; Amini, Roghayeh

    2013-11-15

    A selective solid phase extraction method, based on nano-structured Mg-Al-Fe(NO3(-)) ternary layered double hydroxide as a sorbent, is developed for the pre-concentration of ultra-trace levels of arsenic (As) prior to determination by electrothermal atomic absorption spectrometry. It is found that both As(III) and As(V) could be quantitatively retained on the sorbent within a wide pH range of 4-12. Accordingly, the presented method is applied to determination of total inorganic As in aqueous solutions. Maximum analytical signal of As is achieved when the pyrolysis and atomization temperatures are close to 900 °C and 2300 °C, respectively. Several variables affecting the extraction efficiency including pH, sample flow rate, amount of nano-sorbent, elution conditions and sample volume are optimized. Under the optimized conditions, the limit of detection (3Sb/m) and the relative standard deviation are 4.6 pg mL(-1) and 3.9%, respectively. The calibration graph is linear in the range of 15.0-650 pg mL(-1) with a correlation coefficient of 0.9979, sorption capacity and pre-concentration factor are 8.68 mg g(-1) and 300, respectively. The developed method is validated by the analysis of a standard reference material (SRM 1643e) and is successfully applied to the determination of ultra-trace amounts of As in different water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Assessment of trace metal concentrations and human health risk in clam (Tapes decussatus) and mussel (Mytilus galloprovincialis) from the Homa Lagoon (Eastern Aegean Sea).

    Science.gov (United States)

    Bilgin, Mustafa; Uluturhan-Suzer, Esin

    2017-02-01

    Seasonal variations of trace metal concentrations (Hg, Cd, Pb, Cr, Zn, and Cu) were investigated in the hepatopancreas and soft tissues (remaining parts of bivalves such as gill, mantle, foot, and muscle) of Tapes decussatus and Mytilus galloprovincialis from the Homa Lagoon. The highest metal concentrations were recorded frequently in February and July in M. galloprovincialis and T. decussatus, respectively. Trace metal levels (except Zn) in the hepatopancreas were higher than those in soft tissue for both bivalves. The results showed that the mean concentrations of Hg, Cd, and Zn for M. galloprovincialis were higher compared to T. decussatus in both tissues. The metal concentrations in both bivalves from the Homa Lagoon were generally below the values of provisional tolerable weekly intake (PTWI) estimates, in terms of human health risk. According to hazard quotient (HQ), Cr values for both species and Cd values for only M. galloprovincialis were found greater than one. Also, total hazard index (THI) values were greater than one in both bivalves, having a potential risk for consumers.

  6. Modulation of capillary condensation by trace component

    Directory of Open Access Journals (Sweden)

    Shiqi Zhou

    2011-06-01

    Full Text Available Impact of trace component on capillary condensation (CC is investigated systematically using a classical density functional theory. It is discovered that (i presence of the trace component makes the CC to occur at much lower condensation pressure than when its absence; (ii Lennard-Jones potential parameters like size parameter and energy parameter of the trace component, and its concentration in the bulk adsorption system, show their effects the most remarkably within a particular range beyond which the effects eventually become insignificant. The present discoveries have implications in low pressure storage of gases, separation and enrichment of low concentration component, and easy control of CC transition, etc.

  7. Ultra-trace Measurements in the WAIS Divide 06A Ice Core, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — These data contain the results of gas chromatography mass spectrometry (GC-MS) analysis of 207 samples from the WAIS Divide 06A ice core. The trace gases found in...

  8. Bioaccumulation of glyphosate and its formulation Roundup Ultra in Lumbriculus variegatus and its effects on biotransformation and antioxidant enzymes

    Energy Technology Data Exchange (ETDEWEB)

    Contardo-Jara, Valeska [Leibniz-Institute of Freshwater Ecology and Inland Fisheries, Department of Inland Fisheries, Biochemical Regulation, Mueggelseedamm 301, 12587 Berlin (Germany)], E-mail: contardo@igb-berlin.de; Klingelmann, Eva [Technische Universitaet Berlin/Berlin Institute of Technology, Department of Ecology, Chair of Soil Protection, Salzufer 12, 10587 Berlin (Germany)], E-mail: eva.klingelmann@TU-Berlin.de; Wiegand, Claudia [Leibniz-Institute of Freshwater Ecology and Inland Fisheries, Department of Inland Fisheries, Biochemical Regulation, Mueggelseedamm 301, 12587 Berlin (Germany); Humboldt University Berlin, Faculty of Biology, Unter den Linden 6, 10099 Berlin (Germany)], E-mail: cwiegand@igb-berlin.de

    2009-01-15

    The bioaccumulation potential of glyphosate and the formulation Roundup Ultra, as well as possible effects on biotransformation and antioxidant enzymes in Lumbriculus variegatus were compared by four days exposure to concentrations between 0.05 and 5 mg L{sup -1} pure glyphosate and its formulation. Bioaccumulation was determined using {sup 14}C labeled glyphosate. The bioaccumulation factor (BCF) varied between 1.4 and 5.9 for the different concentrations, and was higher than estimated from log P{sub ow}. Glyphosate and its surfactant POEA caused elevation of biotransformation enzyme soluble glutathione S-transferase at non-toxic concentrations. Membrane bound glutathione S-transferase activity was significantly elevated in Roundup Ultra exposed worms, compared to treatment with equal glyphosate concentrations, but did not significantly differ from the control. Antioxidant enzyme superoxide dismutase was significantly increased by glyphosate but in particular by Roundup Ultra exposure indicating oxidative stress. The results show that the formulation Roundup Ultra is of more ecotoxicological relevance than the glyphosate itself. - Roundup Ultra is of more ecotoxicological relevance than the active ingredient, glyphosate, to Lumbriculus variegatus regarding accumulation potential and enzymatic responses.

  9. Bioaccumulation of glyphosate and its formulation Roundup Ultra in Lumbriculus variegatus and its effects on biotransformation and antioxidant enzymes

    International Nuclear Information System (INIS)

    Contardo-Jara, Valeska; Klingelmann, Eva; Wiegand, Claudia

    2009-01-01

    The bioaccumulation potential of glyphosate and the formulation Roundup Ultra, as well as possible effects on biotransformation and antioxidant enzymes in Lumbriculus variegatus were compared by four days exposure to concentrations between 0.05 and 5 mg L -1 pure glyphosate and its formulation. Bioaccumulation was determined using 14 C labeled glyphosate. The bioaccumulation factor (BCF) varied between 1.4 and 5.9 for the different concentrations, and was higher than estimated from log P ow . Glyphosate and its surfactant POEA caused elevation of biotransformation enzyme soluble glutathione S-transferase at non-toxic concentrations. Membrane bound glutathione S-transferase activity was significantly elevated in Roundup Ultra exposed worms, compared to treatment with equal glyphosate concentrations, but did not significantly differ from the control. Antioxidant enzyme superoxide dismutase was significantly increased by glyphosate but in particular by Roundup Ultra exposure indicating oxidative stress. The results show that the formulation Roundup Ultra is of more ecotoxicological relevance than the glyphosate itself. - Roundup Ultra is of more ecotoxicological relevance than the active ingredient, glyphosate, to Lumbriculus variegatus regarding accumulation potential and enzymatic responses

  10. Trace element concentrations of wild saltwater crocodile eggs

    International Nuclear Information System (INIS)

    Manolis, S.C.; Webb, G.J.; Britton, A.R.; Jeffree, R.A.; Markich, S.J.

    2002-01-01

    Saltwater crocodiles (Crocodylus porosus) accumulate trace elements from the environment into their flesh and bones (Jeffree et al., 2001a). Elevated levels of metals (e.g. Hg, Zn, Pb), organochlorines (e.g. DDT) and radionuclides (e.g. radiocesium) have been recorded in blood, tissues and eggs of several crocodilian species (Manolis et al., this volume). In this study the concentrations of various elements (including metals) were measured in the yolk of C. porosus eggs collected from the Finniss River and two other distant nesting sites (Melacca Swamp, a spring-fed freshwater swamp; Adelaide River, a tidal river) during the 2000- 01 nesting season. Infertile eggs from 30 clutches (Adelaide 12, Melacca 8, Finniss 10) were opened and the yolk contents removed (after Webb et al., 1987) and frozen. Samples of yolk were then oven-dried, digested in nitric acid and hydrogen peroxide. The digest solutions were then analysed for 20 elements (see Table 1) using inductively coupled plasma mass spectroscopy. Similarities between the elemental composition of eggs from the three areas suggests that downstream contamination from Rum Jungle Mine is not apparent in C. porosus nesting in the Finniss River. These nesting areas are some 60 km downstream of the mine site, and contaminants are probably greatly diluted during the wet season. C. porosus were also intensively hunted in the Finniss River area during the 1950s and 1960s, until their protection in 1971 (Webb et al. 1984). Some females would have been recruited into the population after the period of mining. Long-term effects of the mine may be apparent in areas with Australian freshwater crocodiles (C. johnstoni), mainly upstream of C. porosus nesting areas and up to the mine. Examination of tissues and eggs of C. johnstoni may provide more information on the historical effects of the mine

  11. Etude de la concentration des metaux traces chez "Hexaplex trunculus " (muricidae) le long du littoral tunisien

    OpenAIRE

    Tissaoui, Ch.; Chouba, L.; El Abed, O.

    2008-01-01

    La Tunisie dispose d’une ressource importante en coquillages, plusieurs espèces sont commercialisées et elles ont fait l’objet de programmes de qualité pour la sauvegarde de la santé humaine. Dans ce contexte, nous avons réalisé un suivi saisonnier de la concentration de trois métaux traces toxiques, le cadmium (Cd), le plomb (Pb), et le mercure (Hg) dans la totalité de la masse molle, dans le pied et dans les viscères d’un Mollusque Gastéropode, l’Hexaplex trunculus communément appelé en Tun...

  12. Application of neutron activation analysis to the study of the variations of the concentration of trace elements in various organs of rat as a function of age

    International Nuclear Information System (INIS)

    Maziere, B.; Loc'h, C.; Stulzaft, O.; Gaudry, A.; Comar, D.

    1976-01-01

    In order to know the normal distribution of trace elements in rats as accurately as possible, the composition of different organs and body tissues by neutron activation analysis was determined in animals from 15 days to 22 months old. The experiment conditions were described. Normal concentrations for more than 20 trace elements were obtained, some of them being less than a tenth of a part per billion. The experiment has shown that variations in elemental concentrations in terms of age were a general phenomenon and that for some elements a steady state is apparently never attained

  13. Concentrations of trace elements in tissues of red fox (Vulpes vulpes) and stone marten (Martes foina) from suburban and rural areas in Croatia.

    Science.gov (United States)

    Bilandžić, Nina; Dežđek, Danko; Sedak, Marija; Dokić, Maja; Solomun, Božica; Varenina, Ivana; Knežević, Zorka; Slavica, Alen

    2010-11-01

    Trace elements concentrations (As, Cd, Cu, Pb and Hg) were determined in the liver, kidney and muscle of 28 red fox (Vulpes vulpes) and 16 stone marten (Martes foina) from suburban and rural habitats from Croatia. Rural and suburban habitats affected Cd and Hg levels in the muscle, liver and kidney of red fox. Significant differences in metal concentrations in the muscle, liver and kidney were detected among species. Suburban stone marten accumulated the highest levels of trace elements (mg/kg w.w.): in muscle 0.019 for Hg; in liver 0.161 for Cd, 36.1 for Cu and 0.349 for Pb; in kidney 1.34 for Cd and 0.318 for Pb. Values observed were higher than those found in suburban red fox and therefore, may represent an important bioindicator for the accumulation of toxic metals in urbanized habitats.

  14. Trace metal concentrations in mussels in the outfall zones of thermal and nuclear power plants

    International Nuclear Information System (INIS)

    Krishna Kumar, P.T.; Sekimoto, Hiroshi

    2008-01-01

    Many trace elements (TE) like Mn, Fe, Cu, and Zn, occur naturally in marine environments and these TE accomplish decisive functions in humans to maintain good health. Living organisms like Mytilus galloprovincialis are a rich source of TE and are grown extensively near the industrial water outfalls. Some of these TE tend to be pollutants when their elevated levels produce deleterious effects on the ecological system. As chemical analysis for TE toxicity are expensive, organisms like Mytilus galloprovincialis can be used as monitors of environmental contamination. Most studies reported so far are directed towards the effect of a single environmental factor on marine bivalves. However in the areas receiving mixed effluents from various point and non-point sources, the studies on combined effect of two or more stresses would be a more practical approach. In this paper, We investigate the heavy metal concentrations of mercury, cadmium, lead, zinc, cooper, nickel, manganese, and chromium in Mytilus galloprovincialis to provide information on the pollution of water bodies by thermal and nuclear power plants for the choice of sites from where edible mussels can be harvested. We also propose a chemometric approach developed by us using information theory to mitigate trace element toxicity in the edible part of Mytilus galloprovincialis harvested in these sites. (author)

  15. Do ultra-orphan medicinal products warrant ultra-high prices? A review

    Directory of Open Access Journals (Sweden)

    Picavet E

    2013-06-01

    Full Text Available Eline Picavet,1 David Cassiman,2 Steven Simoens1 1Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Leuven, Belgium; 2Department of Hepatology, University Hospital Leuven, Leuven, Belgium Abstract: Ultra-orphan medicinal products (ultra-OMPs are intended for the treatment, prevention, or diagnosis of ultra-rare diseases, ie, life-threatening or chronically debilitating diseases that affect less than one per 50,000 individuals. Recently, high prices for ultra-OMPs have given rise to debate on the sustainability and justification of these prices. The aim of this article is to review the international scientific literature on the pricing of ultra-OMPs and to provide an overview of the current knowledge on the drivers of ultra-OMP pricing. The pricing process of ultra-OMPs is a complex and nontransparent issue. Evidence in the literature seems to indicate that ultra-OMPs are priced according to rarity and what the manufacturer believes the market will bear. Additionally, there appears to be a trend between the price of an ultra-OMP and the number of available alternatives. Patients, third-party payers, and pharmaceutical companies could benefit from more transparent pricing strategies. With a view to containing health care costs, it is likely that cost-sharing strategies, such as performance-based risk sharing arrangements, will become increasingly more important. However, it is vital that any measures for price control are consistent with the intended goals of the incentives to promote the development of new OMPs. Ideally, a balance must be struck between attaining affordable prices for ultra-OMPs and securing a realistic return on investment for the pharmaceutical industry. Keywords: ultra-orphan medicinal product, ultra-rare disease, pricing

  16. Spatial variations in trace element concentrations of the sea urchin, Paracentrotus lividus, a first reference study in the Mediterranean Sea.

    Science.gov (United States)

    Ternengo, S; Marengo, M; El Idrissi, O; Yepka, J; Pasqualini, V; Gobert, S

    2018-04-01

    A study on Trace Elements (TE) from sea urchin gonads has been conducted in the western Mediterranean Sea. Contamination data were used to determine a Trace Method Pollution Index (TEPI). TE concentrations varied considerably depending on the location of the sampling stations. The results showed that five trace elements (Zn, Fe, As, Al, Cu) are ubiquitous. The geographical area considered (Corsica) represents an important range of environmental conditions and types of pressure that can be found in the western Mediterranean Sea. TEPI was used to classify the studied sites according to their degree of contamination and allowed reliable comparison of TE contamination between local and international sites. TE contamination of the western Mediterranean Sea displayed a north-to-south gradient, from the Italian coasts down through the insular Corsican coasts to the north African littoral. Due to the increasing environmental pressure on the Mediterranean Sea, a regular monitoring of TE levels in marine organisms is necessary to prevent any further environmental deterioration. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Determination of trace elements in airborne particulate matter. Pt. 2

    International Nuclear Information System (INIS)

    Pamuk, F.; Kahraman, N.; Kut, D.

    1975-04-01

    Several trace elements are being introduced into the atmosphere from various sources. Since many of the trace elements are highly toxic, the concentrations of them should be measured and controlled continuously for public health. Concentrations of trace elements have been determined in air samples collected from seven different districts of Ankara by the use of instrumental neutron activation analysis and atomic absorption spectrophotometer. (Pamuk, F.; Kahraman, N.; Kut, D.)

  18. Major, Trace Element Concentration and Triple-Oxygen Isotope Compositions of G- and I-Type Spherules from the Sør Rondane Mountains, East Antarctica

    Science.gov (United States)

    Soens, B.; Goderis, S.; Greenwood, R. C.; McKibbin, S.; Van Ginneken, M.; Vanhaecke, F.; Debaille, V.; Franchi, I. A.; Claeys, Ph.

    2017-07-01

    We present new major, trace element concentration (LA-ICP-MS) and triple-oxygen isotope (LF-IRMS) data for G- and I-type cosmic spherules. This study suggests that both types of micrometeorites may originate from ordinary chondrite parent bodies.

  19. Correlations between atmospheric aerosol trace element concentrations and red tide at Port Aransas, Texas, on the Gulf of Mexico

    International Nuclear Information System (INIS)

    Biegalski, S.R.; Villareal, T.A.

    2005-01-01

    Neutron activation analysis (NAA) was employed as an analytical technique to measure atmospheric aerosol concentrations of trace metals in Port Aransas, TX on the Gulf of Mexico. The sources of atmospheric aerosols and the seasonal variation of the sources are explored. High atmospheric iron concentrations are then shown to have a possible correlation to the occurrences of red tide in this region. The data shows that this correlation is plausible, but due to the many factors that affect red tide growth a definitive conclusion may not be reached. The period of study for these measurements was September 12, 2000 to January 4, 2002. (author)

  20. Trace element concentration in soils and plants in the vicinity of Miduk copper mine

    Directory of Open Access Journals (Sweden)

    Farid Moore

    2014-10-01

    Full Text Available Introduction High concentrations of metals are usually encountered in surface soil and vegetation in areas affected by mining activity (Liu et al., 2006. Different distribution of elements in chemical fractions result in different bioavailability; therefore knowledge of the total content of an element in soil is not a sufficient criterion to estimate the environmental implications of trace metal presence (Maiz et al., 2000. Sequential extraction analysis gives information on the element distribution among different phases of soil. Several schemes of sequential extraction are used for the determination of commonly distinguished metal species, which are in general: (1 easily exchangeable or water soluble; (2 specifically sorbed; e.g., by carbonates or phosphates; (3 organically bound; (4 occluded by Fe-Mn oxides and hydroxides; and (5 structurally bound in minerals or residual (Kabata-Pendias and Mukherjee, 2007. The main objectives of this study are: (1 to describe the distribution pattern of elements in rocks and soils of the Miduk area; (2 to assess the fractionation of elements in soil and the mining impact on the mobility of trace elements; (3 to investigate the uptake of analyzed elements by selected indigenous plant species. Materials and Methods In this study, 32 soil samples at two depths (0-5 cm and 15-20 cm, were analyzed for total concentration of 45 elements. In order to assess the possible bioaccumulation of the elements, the roots and the overground parts of 3 plant species (Astragalus-Fabaceae, Acanthophyllum -Caryophyllaceae, Artemisia -Asteraceae were also collected and analyzed. Enrichment factors (EFs were calculated to assess whether the concentrations observed represent background or contaminated levels. The Tessier et al. method (Tessier et al., 1979 was chosen for sequential extraction of 6 subsoil samples. Correlation analysis was used to examine the relationship between the analyzed elements in soil. The plant’s ability

  1. Trace elements distribution in environmental compartments

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Juliana C. de; Peres, Sueli da Silva; Godoy, Maria Luiza D.P., E-mail: suelip@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    Trace elements term defines the presence of low concentrations metals at environment. Some of them are considered biologically essential, as Co, Cu and Mn. Others can cause detriment to environment and human health, as Pb, Cd, Hg, As, Ti and U. A large number of them have radioactive isotopes, implying the evaluation of risks for human health should be done considering the precepts of environmental radiological protection. The ecosystem pollution with trace elements generates changes at the geochemistry cycle of these elements and in environmental quality. Soils have single characteristics when compared with another components of biosphere (air, water and biota), cause they introduce themselves not only as a drain towards contaminants, but also as natural buffer that control the transport of chemical elements and other substances for atmosphere, hydrosphere and biota. The main purpose of environmental monitoring program is to evaluate the levels of contaminants in the various compartments of the environment: natural or anthropogenic, and to assess the contribution of a potential contaminant source on the environment. Elemental Composition for the collected samples was determined by inductively coupled plasma mass spectroscopy. The main objective of this work was to evaluate the map baseline of concentration of interest trace elements in environmental samples of water, sediment and soil from Environmental Monitoring Program of Instituto de Radioprotecao e Dosimetria (IRD). The samples were analyzed using an inductively coupled plasma mass spectrometer (ICP-MS) at IRD. >From the knowledge of trace elements concentrations, could be evaluated the environmental quality parameters at the studied ecosystems. The data allowed evaluating some relevant aspects of the study of trace elements in soil and aquatic systems, with emphasis at the distribution, concentration and identification of main anthropic sources of contamination at environment. (author)

  2. Trace elements distribution in environmental compartments

    International Nuclear Information System (INIS)

    Queiroz, Juliana C. de; Peres, Sueli da Silva; Godoy, Maria Luiza D.P.

    2017-01-01

    Trace elements term defines the presence of low concentrations metals at environment. Some of them are considered biologically essential, as Co, Cu and Mn. Others can cause detriment to environment and human health, as Pb, Cd, Hg, As, Ti and U. A large number of them have radioactive isotopes, implying the evaluation of risks for human health should be done considering the precepts of environmental radiological protection. The ecosystem pollution with trace elements generates changes at the geochemistry cycle of these elements and in environmental quality. Soils have single characteristics when compared with another components of biosphere (air, water and biota), cause they introduce themselves not only as a drain towards contaminants, but also as natural buffer that control the transport of chemical elements and other substances for atmosphere, hydrosphere and biota. The main purpose of environmental monitoring program is to evaluate the levels of contaminants in the various compartments of the environment: natural or anthropogenic, and to assess the contribution of a potential contaminant source on the environment. Elemental Composition for the collected samples was determined by inductively coupled plasma mass spectroscopy. The main objective of this work was to evaluate the map baseline of concentration of interest trace elements in environmental samples of water, sediment and soil from Environmental Monitoring Program of Instituto de Radioprotecao e Dosimetria (IRD). The samples were analyzed using an inductively coupled plasma mass spectrometer (ICP-MS) at IRD. >From the knowledge of trace elements concentrations, could be evaluated the environmental quality parameters at the studied ecosystems. The data allowed evaluating some relevant aspects of the study of trace elements in soil and aquatic systems, with emphasis at the distribution, concentration and identification of main anthropic sources of contamination at environment. (author)

  3. Trace elements in particulate matter from metropolitan regions of Northern China: Sources, concentrations and size distributions.

    Science.gov (United States)

    Pan, Yuepeng; Tian, Shili; Li, Xingru; Sun, Ying; Li, Yi; Wentworth, Gregory R; Wang, Yuesi

    2015-12-15

    Public concerns over airborne trace elements (TEs) in metropolitan areas are increasing, but long-term and multi-site observations of size-resolved aerosol TEs in China are still lacking. Here, we identify highly elevated levels of atmospheric TEs in megacities and industrial sites in a Beijing-Tianjin-Hebei urban agglomeration relative to background areas, with the annual mean values of As, Pb, Ni, Cd and Mn exceeding the acceptable limits of the World Health Organization. Despite the spatial variability in concentrations, the size distribution pattern of each trace element was quite similar across the region. Crustal elements of Al and Fe were mainly found in coarse particles (2.1-9 μm), whereas the main fraction of toxic metals, such as Cu, Zn, As, Se, Cd and Pb, was found in submicron particles (metals were enriched by over 100-fold relative to the Earth's crust. The size distributions of Na, Mg, K, Ca, V, Cr, Mn, Ni, Mo and Ba were bimodal, with two peaks at 0.43-0.65 μm and 4.7-5.8 μm. The combination of the size distribution information, principal component analysis and air mass back trajectory model offered a robust technique for distinguishing the main sources for airborne TEs, e.g., soil dust, fossil fuel combustion and industrial emissions, at different sites. In addition, higher elemental concentrations coincided with westerly flow, indicating that polluted soil and fugitive dust were major sources of TEs on the regional scale. However, the contribution of coal burning, iron industry/oil combustion and non-ferrous smelters to atmospheric metal pollution in Northern China should be given more attention. Considering that the concentrations of heavy metals associated with fine particles in the target region were significantly higher than those in other Asian sites, the implementations of strict environmental standards in China are required to reduce the amounts of these hazardous pollutants released into the atmosphere. Copyright © 2015 Elsevier B

  4. Assessment of concentrations of trace and toxic heavy metals in soil and vegetables grown in the vicinity of Manyoni uranium deposit in Tanzania

    International Nuclear Information System (INIS)

    Kapile, F.A.; Makundi, I.N.

    2016-01-01

    This study reports on determination of concentrations of trace and toxic heavy metals in soil and vegetables grown near of Manyoni uranium deposit. Soil and vegetable samples were collected from five sites namely Mitoo Mbuga, farming area, Miyomboni, Tambukareli and near water pump. The concentrations of heavy metals in soil and edible vegetables samples were analyzed using Energy Dispersive X-ray Fluorescence Spectrometry (EDXRF).All vegetable samples were found to have higher concentrations (in μg/g) of trace elements such as Ni (67.3) in pea leaves, Cu (14.9) in pumpkin leaves, Fe (478.6), (200.5) and (337.1) in pea, pumpkin and spinach leaves respectively, than the maximum tolerable limits recommended by WHO/FAO. Mean concentration of Pb (1.6 μg/g) in pumpkin leaves collected from Miyomboni (area D) were observed to be higher than the safe limit of (0.3μg/g) set by Codex 2006. Toxic elements concentrations (in μg/g) such as Cd (10.4), Pb (23.2),Hg (4.1), Th (31.5) and U (23.9) were observed to be high in soil collected from Mitoo Mbuga and farming area. Therefore, vegetables in the vicinity of Manyoni uranium deposit can expose people to toxic elements which are detrimental to their health.A more detailed study involving other foodstuffs is needed to establish conclusive results.

  5. From trace chemistry to single atom chemistry

    International Nuclear Information System (INIS)

    Adloff, J.P.

    1993-01-01

    Hot atom chemistry in the vast majority of experimental works deals with the trace amount of radioactive matters. Accordingly, the concept of trace chemistry is at the heart of hot atom chemistry. Some aspects of the chemistry at trace scale and at subtrace scale are presented together with the related problems of speciation and the complication which may arise due to the formation of radio colloids. The examples of 127 I(n,γ) 128 I and 132 Te (β - ) 132 I are shown, and the method based on radioactivity was used. The procedure of separating the elements in pitchblende is shown as the example of the chemistry of traces. 13 27 Al+ 2 4 He→ 0 1 n+ 15 30 P and 15 30 P→ 14 30 Si+e + +V are shown, and how to recognize the presence of radioactive colloids is explained. The formation of radiocolloids is by the sorption of a trace radioelement on pre-existing colloidal impurity or the self-condensation of monomeric species. The temporal parameters of the nature of reactions at trace concentration are listed. The examples of Class A and Class B reactions are shown. The kinetics of reactions at trace level, radon concentration, anthropogenic Pu and natural Pu in environment, the behavior of Pu atoms and so on are described. (K.I.)

  6. Trace contaminant concentration affects mineral transformation and pollutant fate in hydroxide-weathered Hanford sediments

    International Nuclear Information System (INIS)

    Perdrial, Nicolas; Rivera, Nelson; Thompson, Aaron; O’Day, Peggy A.; Chorover, Jon

    2011-01-01

    Highlights: ► Fate of Sr, Cs and I tracked during hydroxide-weathering of sediments. ► pCO 2 and contaminant concentration affected mineral transformation. ► Sodalite/cancrinite formed at μM levels, chabazite at mM levels. ► Absence of CO 2 resulted in calcite dissolution and strätlingite formation. ► Trace contaminant concentrations modified their own sequestration path. - Abstract: Prior work has shown that when silicaceous sediments are infused with caustic radioactive waste, contaminant fate is tightly coupled to ensuing mineral weathering reactions. However, the effects of local aqueous geochemical conditions on these reactions are poorly studied. Thus, we varied contaminant concentration and pCO 2 during the weathering of previously uncontaminated Hanford sediments over 6 months and 1 year in a solution of caustic waste (pH 13, high ionic strength). Co-contaminants Sr, Cs and I were added at “low” (Cs/Sr: 10 −5 m; I: 10 −7 m) and “high” (Cs/Sr: 10 −3 m; I: 10 −5 m) concentrations, and headspace was held at atmospheric or undetectable ( 2 partial pressure. Solid phase characterization revealed the formation of the zeolite chabazite in “high” samples, whereas feldspathoids, sodalite and cancrinite, were formed preferentially in “low” samples. Sr, Cs and I were sequestered in all reacted sediments. Native calcite dissolution in the CO 2 -free treatment drove the formation of strätlingite (Ca 2 Al 2 SiO 7 ·8H 2 O) and diminished availability of Si and Al for feldspathoid formation. Results indicate that pCO 2 and contaminant concentrations strongly affect contaminant speciation in waste-weathered sediments, and are therefore likely to impact reaction product stability under any remediation scenario.

  7. Determination of trace elements in drinking tea by various analytical techniques

    International Nuclear Information System (INIS)

    Wang Chufang; Ke Chenghsiung; Yang Jenqyann

    1993-01-01

    Tea has been one of the most popular simulating beverages which is both heavily produced and consumed in Taiwan. The determination of minor or trace elements in drinking tea and tea leaves is therefore important for estimating the daily intake of Taiwanese considered as a safety indicator. In order to accurately and precisely determine the concentrations of trace elements in samples, several analytical methods such as AAS, NAA and ICP-AES are suggested. This paper attempts to utilize all three methods to determine the concentrations of minor or trace elements in different types of tea leaves and the extracts percolated from them. The influence of fermentation processes on the concentration levels of minor or trace elements in tea samples is investigated. Because only free metal ions are bioavailable for the human body, it is necessary to determine their concentrations in drinking tea. The dissolution of trace elements in drinking tea is therefore studied by simulating the common Chinese style of tea percolation. Concentrations of thirteen elements including Zn, Mn, Ca, Cu, Ni, Al, K, Mg, Cd, Pb, Na, Co and Sc are determined. (author) 14 refs.; 1 fig.; 6 tabs

  8. Determination of trace element concentration in infant head hair of Rawalpindi/Islamabad area using INAA technique

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Gill, K.P.

    2004-01-01

    The concentration of 18 minor and trace elements (essential, toxic and nonessential) in infant head hair was determined. The data provide the base-line values of these elements in head hair of infants of low- and medium-income group subjects. The statistical results show that there are significant correlations between some elements such as: Ca-Zn, Ca-Fe, Mg-Ca, Mg-Mn and Mg-Fe. The results obtained have been compared with the data reported in the literature. Our data show compatibility of elemental contents of infant head hair with those from some of the other geological regions but also deviate in some cases. (orig.)

  9. Trace element analysis of soy sauce

    International Nuclear Information System (INIS)

    Tomita, Michio; Haruyama, Yoichi; Saito, Manabu

    1994-01-01

    Trace elements in soy sauce have been measured by means of in-air PIXE. Six kinds of trace elements were detected, such as Mu, Fe, Ni, Zn, Cu and Br. Concentrations of Mn, Fe, Zn and Br which were observed in all samples, have been determined. Each analyzed sample contained considerable amount of bromine about 160 ppm. (author)

  10. Studies of cation exchange for the isolation and concentration of trace level components of complex aqueous mixtures

    International Nuclear Information System (INIS)

    Kaczvinsky, J.R. Jr.

    1984-01-01

    Trace level organic bases are concentrated from aqueous solution by cation exchange on a column of sulfonated macroreticular XAD-4 resin. Washing of the column with organic solvents removes neutrals and acids. Ammonia gas is introduced into the column prior to elution of the basic organics with either methanol or ether containing ammonia. After solvent evaporation, the concentrated sample is analyzed by gas chromatography. Recoveries of over 85% are found with at least one of the eluents for over 50 bases tested at levels < 1 ppm. Improved recoveries and reproducibility are seen over a simple ether extraction procedure. Samples of river water, shale oil process water, and supernatant from an agricultural chemical disposal pit are analyzed. Preliminary studies of functionalized poly(styrene-divinylbenzene)s, coated exchangers, and liquid ion exchangers as possible approaches to nuclear waste decontamination are performed

  11. Measurement of 239Pu in urine samples at ultra-trace levels using a 1 MV compact AMS system

    International Nuclear Information System (INIS)

    Hernandez-Mendoza, H.; Chamizo, E.; Yllera, A.; Garcia-Leon, M.; Delgado, A.

    2010-01-01

    Routine bioassay monitoring of Pu intake in exposed workers of research and nuclear industry is usually performed by alpha spectrometry. This technique involves large sample volumes of urine and time-consuming preparative and counting protocols. Compact accelerator mass spectrometry (AMS) facilities make feasible the determination of ultra low-level Pu activity concentrations and Pu isotopic ratios in biological samples (blood, urine and feces), being a rapid and cost-effective measurement technique. The plutonium results in urine samples presented here have been obtained on the 1 MV compact AMS system sited at the Centro Nacional de Aceleradores (CNA), in Seville, Spain. In this work, a different methodological approach has been developed alternative to the 'classical' preparation of urine samples for alpha spectrometry. The procedure avoids the Pu precipitation step, and involves acid sample evaporation and acid digestion in a microwave oven. Finally, purification of plutonium was achieved by using chromatography columns filled up with BioRad AG1X2 anion exchange resin (Bio-Rad Laboratories Inc.). The total time needed for analysis is about 10 h, unlike the 'classical' methods based on alpha spectrometry which need about 1 week. At present, it has been demonstrated that this method allows quantifying 239 Pu activity concentrations in urine of, at least, 30 μBq (13 fg 239 Pu). We can conclude that the procedure would be suitable to perform in vitro routine bioassay measurements. Moreover, the innovative application of AMS opens new and interesting analytical alternatives in this field.

  12. Trace elements in agroecosystems and impacts on the environment.

    Science.gov (United States)

    He, Zhenli L; Yang, Xiaoe E; Stoffella, Peter J

    2005-01-01

    Trace elements mean elements present at low concentrations (mg kg-1 or less) in agroecosystems. Some trace elements, including copper (Cu), zinc (Zn), manganese (Mn), iron (Fe), molybdenum (Mo), and boron (B) are essential to plant growth and are called micronutrients. Except for B, these elements are also heavy metals, and are toxic to plants at high concentrations. Some trace elements, such as cobalt (Co) and selenium (Se), are not essential to plant growth but are required by animals and human beings. Other trace elements such as cadmium (Cd), lead (Pb), chromium (Cr), nickel (Ni), mercury (Hg), and arsenic (As) have toxic effects on living organisms and are often considered as contaminants. Trace elements in an agroecosystem are either inherited from soil parent materials or inputs through human activities. Soil contamination with heavy metals and toxic elements due to parent materials or point sources often occurs in a limited area and is easy to identify. Repeated use of metal-enriched chemicals, fertilizers, and organic amendments such as sewage sludge as well as wastewater may cause contamination at a large scale. A good example is the increased concentration of Cu and Zn in soils under long-term production of citrus and other fruit crops. Many chemical processes are involved in the transformation of trace elements in soils, but precipitation-dissolution, adsorption-desorption, and complexation are the most important processes controlling bioavailability and mobility of trace elements in soils. Both deficiency and toxicity of trace elements occur in agroecosystems. Application of trace elements in fertilizers is effective in correcting micronutrient deficiencies for crop production, whereas remediation of soils contaminated with metals is still costly and difficult although phytoremediation appears promising as a cost-effective approach. Soil microorganisms are the first living organisms subjected to the impacts of metal contamination. Being responsive and

  13. Heavy metals and related trace elements

    International Nuclear Information System (INIS)

    Leland, H.V.; Luoma, S.N.; Wilkes, D.J.

    1977-01-01

    A review is given of heavy metals and related trace elements in the aquatic environment. Other reviews and bibliographies are cited, dealing with the metabolism and transport of metal ions and with the toxic effects of stable and radioactive trace metals on aquatic organisms. The sources of trace elements in natural waters are discussed. It is suggested that atmospheric inputs of several trace metals comprise sizable fractions of total inputs to the Great Lakes and continental shelf waters. Information on stack emissions of trace elements from a coal-fired steam plant was used to estimate the likely range of air concentrations and inputs to a forested watershed in Tennessee. Some basic concepts of cycling of elements through aquatic communities were examined, such as the Pb, Mn and Zn concentrations in sediment and estuarine plants and animals colonizing dredge-spoil disposal areas. The use of plants as biological indicators of trace element contamination was outlined, as well as bioaccumulation in aquatic fauna. The effects of environmental factors on the kinetics of element exchange were noted, for example the influx rates of Cs 137 in tubificid worms, and Co 60 and Zn 65 in shrimp were shown to be temperature dependent. The toxicity of heavy metals on aquatic fauna was discussed, such as the histopathological lesions in the kidney and liver of fishes caused by heavy metals, and the effects of Hg and Cu on the olfactory response of rainbow trout

  14. A laser-based FAIMS detector for detection of ultra-low concentrations of explosives

    Science.gov (United States)

    Akmalov, Artem E.; Chistyakov, Alexander A.; Kotkovskii, Gennadii E.; Sychev, Alexey V.; Tugaenko, Anton V.; Bogdanov, Artem S.; Perederiy, Anatoly N.; Spitsyn, Eugene M.

    2014-06-01

    A non-contact method for analyzing of explosives traces from surfaces was developed. The method is based on the laser desorption of analyzed molecules from the surveyed surfaces followed by the laser ionization of air sample combined with the field asymmetric ion mobility spectrometry (FAIMS). The pulsed radiation of the fourth harmonic of a portable GSGG: Cr3+ :Nd3+ laser (λ = 266 nm) is used. The laser desorption FAIMS analyzer have been developed. The detection limit of the analyzer equals 40 pg for TNT. The results of detection of trinitrotoluene (TNT), cyclotrimethylenetrinitramine (RDX) and cyclotetramethylenetetranitramine (HMX) are presented. It is shown that laser desorption of nitro-compounds from metals is accompanied by their surface decomposition. A method for detecting and analyzing of small concentrations of explosives in air based on the laser ionization and the FAIMS was developed. The method includes a highly efficient multipass optical scheme of the intracavity fourthharmonic generation of pulsed laser radiation (λ = 266 nm) and the field asymmetric ion mobility (FAIM) spectrometer disposed within a resonator. The ions formation and detection proceed inside a resonant cavity. The laser ion source based on the multi-passage of radiation at λ = 266 nm through the ionization region was elaborated. On the basis of the method the laser FAIMS analyzer has been created. The analyzer provides efficient detection of low concentrations of nitro-compounds in air and shows a detection limit of 10-14 - 10-15 g/cm3 both for RDX and TNT.

  15. Comparative study on TSPM levels, anions and trace metal concentrations at BARC during the years 2000-2002

    International Nuclear Information System (INIS)

    Saradhi, I.V.; Prathibha, P.; Kothai, G.; Mahadevan, T.N.; Venkat Raj, V.; Kumar, Shaji C.

    2003-01-01

    Both total and respirable suspended particulate matter in the ambient air of Mumbai have been identified as the single largest pollutant associated with the health impacts in the community. This study deals with the extensive monitoring work carried out at BARC, Trombay during the period 2000-2002. The paper also deals with the comparative status of the TSPM levels and select trace metal and anion concentrations. While Pb levels have stabilized over the years following the introduction of unleaded gasoline, sulphate as a major contributor in the fine fraction of SPM assumes importance. The possible source profiles are presented and discussed. (author)

  16. Ion chromatography separation of lanthanides at trace concentrations from Gd Matrix and quantification by ICP-MS

    International Nuclear Information System (INIS)

    Raut, V.V.; Jeyakumar, S.; Nagar, B.K.; Deb, S.B.; Saxena, M.K.; Tomar, B.S.

    2014-01-01

    Gadolinium compounds are mainly used as burnable poison. The presence of certain impurities is undesirable in the nuclear grade Gd compounds. Gd 2 O 3 , a most common raw material used for the preparation of nuclear grade Gd compounds. Analysis of rare earth impurities in Gd-matrices is one of the important exercises carried out to ensure the purity of Gd 2 O 3 . Determination of lanthanides at trace concentrations in lanthanide (Gd) matrix is complicated and difficult to realize. This is because the selective separation of REE's in one of the lanthanide elements is a challenging task. The present study was carried out to explore the feasibility of separating trace level lanthanides from Gd matrix by ion interaction chromatography (IIC) and to develop an analytical methodology for the determination of lanthanides by inductively coupled plasma mass spectrometry (ICP-MS). In the present investigation, the reversed phase column was dynamically modified into sulphonic acid functionalized surface by using 0.025 M n-Octane sulphonic acid (OSA). With α-HIBA eluent system, the elution order follows as Lu to La. The separations are employed with gradient elution mode. Since the sample has large excess of Gd, elution profiles with concentration gradient of HIBA were attempted. Separated fractions of Light lanthanides (LLn) and Heavy lanthanides (HLn) were collected and analyzed by ICP-MS. During MS analysis, it was observed that due to high concentration of salt (Na salt of OSA) present in the collected fractions caused difficulty in ICP-MS . Hence the experiments were carried out using another ion interacting reagent viz. 0.03 M camphor-10-sulphonic acid (CSA). Initial concentration of HIBA was kept at 0.025 M up to 15 min for the elution of HLns i.e. from Lu to Tb and it was then increased to 0.05 M to 0.3 M in 30 min. After elution of Tb, outlet of the column was switched to drain for 7 min to separate bulk Gd fraction. From 22 to 35 min effluent fraction containing Eu

  17. Trace metal concentrations in marine zooplankton from the western Bay of Bengal

    Digital Repository Service at National Institute of Oceanography (India)

    Rejomon, G.; Balachandran, K.K.; Nair, M.; Joseph, T.

    on the interrelationships of zooplankton and phytoplankton. – Journal of Marine Biological Association U.K 32: 375-445. [2] Brooks, R.R., Presley, B.J., Kaplan, I.R. (1967): APDC-MIBK extraction system for the determination of trace elements in saline waters by Atomic... of contaminants in the food web dynamics as well as in the biogeochemical cycling of trace elements. Zooplanktons are the most abundant animals in the sea, which play an important role in the marine food chain. They mostly feed on phytoplankton and in turn...

  18. Trace elements in sera from patients with visceral leishmaniasis

    Energy Technology Data Exchange (ETDEWEB)

    Mukhopadhyay, R.; Bhattacharya, A. [Department of Zoology, Calcutta University, Calcutta (India); Chakraborty, A.; Sudarshan, M.; Jal, P.K.; Chintalapudi, S.N. [Inter University Consortium for DAE Facilities, Calcutta Centre 3/LB-8, Bidhan Nagar, Calcutta (India); Dutta, R.K. [Schonland Research Centre for Nuclear Sciences, University of Witwatersrand, Johannesburg (South Africa)

    2000-07-01

    Trace elements are known to have pivotal role in human health and disease. Present investigation employed PIXE analysis to probe into the elemental profile of patients suffering from visceral Leishmaniasis. Remarkable alternations were observed in concentration of elements like Cl, K, Ca, Mn, Fe, Cu, Zn. The pattern of enhancement of elemental concentration corresponds to the progression of the disease. Additionally, our present data reflect probable correlation between alteration in trace elemental status and other pathological syndromes associated with Leishmaniasis. The possibility of considering trace elements as a diagnostic marker for a better understanding of the disease is discussed. (author)

  19. Trace elements in sera from patients with visceral leishmaniasis

    International Nuclear Information System (INIS)

    Mukhopadhyay, R.; Bhattacharya, A.; Chakraborty, A.; Sudarshan, M.; Jal, P.K.; Chintalapudi, S.N.; Dutta, R.K.

    2000-01-01

    Trace elements are known to have pivotal role in human health and disease. Present investigation employed PIXE analysis to probe into the elemental profile of patients suffering from visceral Leishmaniasis. Remarkable alternations were observed in concentration of elements like Cl, K, Ca, Mn, Fe, Cu, Zn. The pattern of enhancement of elemental concentration corresponds to the progression of the disease. Additionally, our present data reflect probable correlation between alteration in trace elemental status and other pathological syndromes associated with Leishmaniasis. The possibility of considering trace elements as a diagnostic marker for a better understanding of the disease is discussed. (author)

  20. Cloud point extraction-flame atomic absorption spectrometry for pre-concentration and determination of trace amounts of silver ions in water samples.

    Science.gov (United States)

    Yang, Xiupei; Jia, Zhihui; Yang, Xiaocui; Li, Gu; Liao, Xiangjun

    2017-03-01

    A cloud point extraction (CPE) method was used as a pre-concentration strategy prior to the determination of trace levels of silver in water by flame atomic absorption spectrometry (FAAS) The pre-concentration is based on the clouding phenomena of non-ionic surfactant, triton X-114, with Ag (I)/diethyldithiocarbamate (DDTC) complexes in which the latter is soluble in a micellar phase composed by the former. When the temperature increases above its cloud point, the Ag (I)/DDTC complexes are extracted into the surfactant-rich phase. The factors affecting the extraction efficiency including pH of the aqueous solution, concentration of the DDTC, amount of the surfactant, incubation temperature and time were investigated and optimized. Under the optimal experimental conditions, no interference was observed for the determination of 100 ng·mL -1 Ag + in the presence of various cations below their maximum concentrations allowed in this method, for instance, 50 μg·mL -1 for both Zn 2+ and Cu 2+ , 80 μg·mL -1 for Pb 2+ , 1000 μg·mL -1 for Mn 2+ , and 100 μg·mL -1 for both Cd 2+ and Ni 2+ . The calibration curve was linear in the range of 1-500 ng·mL -1 with a limit of detection (LOD) at 0.3 ng·mL -1 . The developed method was successfully applied for the determination of trace levels of silver in water samples such as river water and tap water.

  1. Trace element composition of hair in the Italian population

    International Nuclear Information System (INIS)

    Clemente, G.F.; Cigna Rossi, L.

    1979-01-01

    The content of the trace elements Ag, Co, Cr, Cs, Fe, Hg, Ni, Rb, Sb, Sc, Se and Zn has been evaluated in hair samples collected from five different groups of subjects in Italy. All the measurements were performed by means of non-destructive neutron activation analysis of the hair samples that were carefully washed before analysis. In most of the samples the Cs, Rb and Sc content was below the detection limit of the analytical method. Each population group was formed of about five individuals of each sex, selected to be representative of the adult population living in a well-defined community. The five groups were chosen from distinct regions with different socio-economical living habits in order to detect the variability, if any, of the trace element burden among the Italian population. The trace element hair concentration of each subject was correlated with the trace element blood concentration and daily urinary excretion in order to differentiate the trace element content due to exogenous deposition on hair from that due to endogenous absorption routes. The results obtained show that the variability of the hair content among the various groups is strongly linked to local environmental factors. The histograms of the individual values of the hair concentration are given for all trace elements measured, together with a statistical analysis of all data. (author)

  2. Uptakes of trace elements in Zn-deficient mice

    International Nuclear Information System (INIS)

    Ohyama, T.; Yanaga, M.; Yoshida, T.; Maetsu, H.; Suganuma, H.; Omori, T.

    2002-01-01

    A multitracer technique was used to obtain uptake rates of essential trace elements in various organs and tissues in Zn-deficient mice. A multitracer solution, containing more than 20 radioisotopes, was injected intraperitoneally into Zn-deficient state mice and control ones. Uptake rates of the radioisotopes were compared with concentrations of trace elements determined by instrumental neutron activation analysis (INAA) in order to study a specific metabolism of Zn and other essential trace elements, such as Mn, Co, Se, Rb, and Sr. The result suggests that Zn is supplied from bone to other organs and tissues and an increase in Co concentration in all organs and tissues depends on its chemical form, under the Z-deficient state. (author)

  3. Sun Ultra 5

    CERN Multimedia

    1998-01-01

    The Sun Ultra 5 is a 64-bit personal computer based on the UltraSPARC microprocessor line at a low price. The Ultra 5 has been declined in several variants: thus, some models have a processor with less cache memory to further decrease the price of the computer.

  4. CdTe amplification nanoplatforms capped with thioglycolic acid for electrochemical aptasensing of ultra-traces of ATP

    Energy Technology Data Exchange (ETDEWEB)

    Shamsipur, Mojtaba, E-mail: mshamsipur@yahoo.com [Department of Chemistry, Razi University, P.O. Box 67149-67346, Kermanshah (Iran, Islamic Republic of); Farzin, Leila [Department of Analytical Chemistry, School of Chemistry, College of Science, University of Tehran, P.O. Box 14174-66191, Tehran (Iran, Islamic Republic of); Tabrizi, Mahmoud Amouzadeh [Research Center for Science and Technology in Medicine,Tehran University of Medical Sciences, P.O. Box 14197-33131, Tehran (Iran, Islamic Republic of); Shanehsaz, Maryam [Analytical Chemistry Research Laboratory, Mobin Shimi Azma Company, P.O. Box 14768-44949, Tehran (Iran, Islamic Republic of)

    2016-12-01

    A “signal off” voltammetric aptasensor was developed for the sensitive and selective detection of ultra-low levels of adenosine triphosphate (ATP). For this purpose, a new strategy based on the principle of recognition-induced switching of aptamers from DNA/DNA duplex to DNA/target complex was designed using thioglycolic acid (TGA)-capped CdTe quantum dots (QDs) as the signal amplifying nano-platforms. Owing to the small size, high surface-to-volume ratio and good conductivity, quantum dots were immobilized on the electrode surface for signal amplification. In this work, methylene blue (MB) adsorbed to DNA was used as a sensitive redox reporter. The intensity of voltammetric signal of MB was found to decrease linearly upon ATP addition over a concentration range of 0.1 nM to 1.6 μM with a correlation coefficient of 0.9924. Under optimized conditions, the aptasensor was able to selectively detect ATP with a limit of detection of 45 pM at 3σ. The results also demonstrated that the QDs-based amplification strategy could be feasible for ATP assay and presented a potential universal method for other small biomolecular aptasensors. - Highlights: • A “signal off” voltammetric aptasensor has been reported. • The DPV technique was used for the determination of ATP. • The determination of ATP up to 1.6 μM with a detection limit 45 pM, respectively.

  5. Ultra-purification of radiostrontium samples by ion chromatography

    International Nuclear Information System (INIS)

    Stadlbauer, E.A.; Trieu, C.; Hingmann, H.; Rohatzsch, H.; Maushart, R.

    1988-01-01

    Environmental radiostrontium analysis demands fast and effective radiochemical separation methods due to the lack of suitable gamma radiation. The procedure described consists in the preconcentration of radiostrontium by precipitation as SrCO 3 together with other alkaline earth metals. Next, strontium is separated from other constituents on a surface-sulfonated cation exchange resin HPIC-CS2. The chemical yields of strontium carrier as well as of radiostrontium were 80%. γ-spectrometry of the strontium eluate leveals less than 0.35 Bq Ra-226 as the remaining ultra trace contamination with a 3 σ error of about 80%. The method reported permits quantitative on-line detection of radiostrontium down to 5 Bq/l or 5 Bq/kg. (orig.)

  6. Trace element analysis in soy sauce. 2

    International Nuclear Information System (INIS)

    Haruyama, Yoichi; Saito, Manabu; Tomita, Michio; Yoshida, Koji.

    1994-01-01

    Trace elements in four kinds of soybean and three kinds of salt have been measured by means of in-air PIXE. In soybeans, which were made in Japan, America, Canada and China, six kinds of trace elements were detected, such as Mn, Fe, Ni, Cu, Zn and Br. The concentration of these elements varied depending on the place they were made. American soybean showed characteristic feature compared with other soybeans. As to the bromine concentration, American soybean contains ten times as much as Japanese one. In salts Br and Sr were detected. (author)

  7. Trace explosives sensor testbed (TESTbed)

    Science.gov (United States)

    Collins, Greg E.; Malito, Michael P.; Tamanaha, Cy R.; Hammond, Mark H.; Giordano, Braden C.; Lubrano, Adam L.; Field, Christopher R.; Rogers, Duane A.; Jeffries, Russell A.; Colton, Richard J.; Rose-Pehrsson, Susan L.

    2017-03-01

    A novel vapor delivery testbed, referred to as the Trace Explosives Sensor Testbed, or TESTbed, is demonstrated that is amenable to both high- and low-volatility explosives vapors including nitromethane, nitroglycerine, ethylene glycol dinitrate, triacetone triperoxide, 2,4,6-trinitrotoluene, pentaerythritol tetranitrate, and hexahydro-1,3,5-trinitro-1,3,5-triazine. The TESTbed incorporates a six-port dual-line manifold system allowing for rapid actuation between a dedicated clean air source and a trace explosives vapor source. Explosives and explosives-related vapors can be sourced through a number of means including gas cylinders, permeation tube ovens, dynamic headspace chambers, and a Pneumatically Modulated Liquid Delivery System coupled to a perfluoroalkoxy total-consumption microflow nebulizer. Key features of the TESTbed include continuous and pulseless control of trace vapor concentrations with wide dynamic range of concentration generation, six sampling ports with reproducible vapor profile outputs, limited low-volatility explosives adsorption to the manifold surface, temperature and humidity control of the vapor stream, and a graphical user interface for system operation and testing protocol implementation.

  8. Effect of long-term intake of lanthanum chloride on the concentrations of some macro- and trace elements in rat brains using NAA

    International Nuclear Information System (INIS)

    Yu Tong; Li Yaming; Ren Yan; Wang Enbo; Xu Hongying; Wang Wenzhong

    2005-01-01

    Effects of long-term intake of lanthanum in drinking water on the concentrations of twelve kinds of macro- and trace elements in rat brains were primarily studied by neutron activation analysis. The results show that, along with the elevation of the dose of lanthanum, more and more elements were affected in the rat brain tissues. Compared with control group, the concentrations of five elements were changed in the 1000 mg/L group. These elements have close relations with brain function. Accordingly, intake of lanthanum may have negative effects on brain function. (authors)

  9. Trace metal contents in barbeque (BBQ) charcoal products

    Energy Technology Data Exchange (ETDEWEB)

    Kabir, Ehsanul [Department of Environment and Energy, Sejong University, 98 Goon Ja Dong, Seoul 143-747 (Korea, Republic of); Kim, Ki-Hyun, E-mail: khkim@sejong.ac.kr [Department of Environment and Energy, Sejong University, 98 Goon Ja Dong, Seoul 143-747 (Korea, Republic of); Yoon, H.O. [Korea Basic Science Institute, Seoul Center, Seoul 136-701 (Korea, Republic of)

    2011-01-30

    In this study, the concentrations of trace elements contained in solid barbeque (BBQ) charcoal products have been investigated. Eleven brands of charcoal products were analyzed, consisting of both Korean (3 types) and imported products (eight types from three countries) commonly available in the Korean market places. The concentrations of trace metals in solid charcoal varied widely across metal types and between samples with the overall range of 5 {mu}g kg{sup -1} (As) to 118 mg kg{sup -1} (Zn). The patterns of metal distribution between different products appeared to be affected by the properties of raw materials and/or the processes involved in their production. Although concentrations of certain trace metals were significantly high in certain charcoal samples, their emission concentrations were below legislative guidelines (e.g., the permissible exposure limit (PEL) set by the Occupational Safety and Health Administration (OSHA)). In light of the potential harm of grilling activities, proper regulation should be considered to control the use of BBQ charcoal from a toxicological viewpoint to help reduce the potential health risks associated with its use.

  10. Trace metal contents in barbeque (BBQ) charcoal products

    International Nuclear Information System (INIS)

    Kabir, Ehsanul; Kim, Ki-Hyun; Yoon, H.O.

    2011-01-01

    In this study, the concentrations of trace elements contained in solid barbeque (BBQ) charcoal products have been investigated. Eleven brands of charcoal products were analyzed, consisting of both Korean (3 types) and imported products (eight types from three countries) commonly available in the Korean market places. The concentrations of trace metals in solid charcoal varied widely across metal types and between samples with the overall range of 5 μg kg -1 (As) to 118 mg kg -1 (Zn). The patterns of metal distribution between different products appeared to be affected by the properties of raw materials and/or the processes involved in their production. Although concentrations of certain trace metals were significantly high in certain charcoal samples, their emission concentrations were below legislative guidelines (e.g., the permissible exposure limit (PEL) set by the Occupational Safety and Health Administration (OSHA)). In light of the potential harm of grilling activities, proper regulation should be considered to control the use of BBQ charcoal from a toxicological viewpoint to help reduce the potential health risks associated with its use.

  11. Simultaneous measurement of trace metal and oxyanion concentrations in water using diffusive gradients in thin films with a chelex-metsorb mixed binding layer

    DEFF Research Database (Denmark)

    Panther, Jared G.; Bennett, William W.; Welsh, David T.

    2014-01-01

    A new diffusive gradients in thin films (DGT) technique with a mixed binding layer (Chelex-100 and the titanium dioxide based adsorbent Metsorb) is described for the simultaneous measurement of labile trace metal (Mn, Co, Ni, Cu, Cd, and Pb) and oxyanion (V, As, Mo, Sb, W, and P) concentrations i...

  12. An evaluation of trace element release associated with acid mine drainage

    International Nuclear Information System (INIS)

    Sullivan, P.J.; Yelton, J.L.

    1988-01-01

    The determination of trace element release from geologic materials, such as oil shale and coal overburden, is important for proper solid waste management planning. The objective of this study was to determine a correlation between release using the following methods: (1) sequential selective dissolution for determining trace element residencies, (2) toxicity characteristic leaching procedure (TCLP), and (3) humidity cell weathering study simulating maximum trace element release. Two eastern oil shales were used, a New Albany shale that contains 4.6 percent pyrite, and a Chattanooga shale that contains 1.5 percent pyrite. Each shale was analyzed for elemental concentrations by soluble, adsorbed, organic, carbonate, and sulfide phases. The results of the results of the selective dissolution studies show that each trace element has a unique distribution between the various phases. Thus, it is possible to predict trace element release based on trace element residency. The TCLP results show that this method is suitable for assessing soluble trace element release but does not realistically assess potential hazards. The results of the humidity cell studies do demonstrate a more reasonable method for predicting trace element release and potential water quality hazards. The humidity cell methods, however, require months to obtain the required data with a large number of analytical measurements. When the selective dissolution data are compared to the trace element concentrations in the TCLP and humidity cell leachates, it is shown that leachate concentrations are predicted by the selective dissolution data. Therefore, selective dissolution may represent a rapid method to assess trace element release associated with acid mine drainage

  13. Trace element analysis: a diagnostic tool

    International Nuclear Information System (INIS)

    Qureshi, I.H.; Cheema, M.N.

    1976-09-01

    The human mody continuously assimilates a variety of elements from the environment, and the concentration of these elements in the blood is regulated by means of various homeostatic mechanisms. Some of the elements, though present in very small amounts, have highly specialized functions in initiating many biochemical reactions. These elements, known as essential trace elements, are closely related to human diseases since their deficiency or excess induces physiological changes. Many diseases such as hypertension, atherosclerosis, diabetes, etc., are related to an imbalance in trace element. The measurement of trace elements in body fluids and tissues can, therefore, be effectively employed for diagnostic tests

  14. Remediation using trace element humate surfactant

    Energy Technology Data Exchange (ETDEWEB)

    Riddle, Catherine Lynn; Taylor, Steven Cheney; Bruhn, Debra Fox

    2016-08-30

    A method of remediation at a remediation site having one or more undesirable conditions in which one or more soil characteristics, preferably soil pH and/or elemental concentrations, are measured at a remediation site. A trace element humate surfactant composition is prepared comprising a humate solution, element solution and at least one surfactant. The prepared trace element humate surfactant composition is then dispensed onto the remediation site whereby the trace element humate surfactant composition will reduce the amount of undesirable compounds by promoting growth of native species activity. By promoting native species activity, remediation occurs quickly and environmental impact is minimal.

  15. Organic Compounds, Trace Elements, Suspended Sediment, and Field Characteristics at the Heads-of-Tide of the Raritan, Passaic, Hackensack, Rahway, and Elizabeth Rivers, New Jersey, 2000-03

    Science.gov (United States)

    Bonin, Jennifer L.; Wilson, Timothy P.

    2006-01-01

    Concentrations of suspended sediment, particulate and dissolved organic carbon, trace elements, and organic compounds were measured in samples from the heads-of-tide of the five tributaries to the Newark and Raritan Bays during June 2000 to June 2003. The samples were collected as part of the New Jersey Department of Environmental Protection Toxics Reduction Workplan/Contaminant Assessment Reduction Program. Samples of streamwater were collected at water-quality sampling stations constructed near U.S. Geological Survey gaging stations on the Raritan, Passaic, Hackensack, Rahway, and Elizabeth Rivers. Sampling was conducted during base-flow conditions and storms. Constituent concentrations were measured to determine the water quality and to calculate the load of sediment and contaminants contributed to the bays from upstream sources. Water samples were analyzed for suspended sediment, dissolved organic carbon, particulate organic carbon, and specific conductance. Samples of suspended sediment and water were analyzed for 98 distinct polychlorinated biphenyl congeners, 7 dioxins, 10 furans, 27 pesticides, 26 polycyclic aromatic hydrocarbons, and the trace elements cadmium, lead, mercury, and methyl-mercury. Measurements of ultra-low concentrations of organic compounds in sediment and water were obtained by collecting 1 to 3 grams of suspended sediment on glass fiber filters and by passing at least 20 liters of filtered water through XAD-2 resin. The extracted sediment and XAD-2 resin were analyzed for organic compounds by high- and low-resolution gas chromatography mass-spectrometry that uses isotope dilution procedures. Trace elements in filtered and unfiltered samples were analyzed for cadmium, lead, mercury, and methyl-mercury by inductively coupled charged plasma and mass-spectrometry. All constituent concentrations are raw data. Interpretation of the data will be completed in the second phase of the study.

  16. Trace mercury determination in drinking and natural water after preconcentration and separation by DLLME-SFO method coupled with cold vapor atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Abdollahi Atousa

    2014-07-01

    Full Text Available A novel dispersive liquid–liquid microextraction based on solidification of floating organic drop (DLLME-SFO for simultaneous separation/preconcentration of ultra trace amounts of mercury was used. A method based on amalgamation was used for collection of gaseous mercury on gold coated sand (Gold trap. The concentration of mercury was determined by cold vapor atomic absorption spectrometry (CV-AAS. The DLLME-SFO behavior of mercury by using dithizone as complexing agent was systematically investigated. The factors influencing, the complex formation and extraction of DLLME-SFO method such as type and volume of extraction and disperser solvents, pH, concentration of salt, centrifuging time and concentration of the chelating agent were optimized. The method was successfully applied to the determination of mercury in drinking and natural water and satisfactory relative recoveries (95–105% were achieved. The proposed procedure was based on very low consumption of organic solvents. The other benefits of the system were sensitive, simple, friendly to the environment, rejection of matrix constituent, low cost, the time consuming and high enrichment factor.

  17. Trace emissions from gaseous combustion

    Energy Technology Data Exchange (ETDEWEB)

    Seebold, J.G. [Chevron Research and Technology Co., Richmond, CA (United States)

    2000-07-01

    The U.S. Clean Air Act (CAA) was amended in 1990 to include the development of maximum achievable control technology (MACT) emission standards for hazardous air pollutants (HAPs) for certain stationary sources by November 2000. MACT emissions standards would affect process heaters and industrial boilers since combustion processes are a potential source for many air toxins. The author noted that one of the problems with MACT is the lack of a clear solid scientific footing which is needed to develop environmentally responsible regulations. In order to amend some of these deficiencies, a 4-year, $7 million research project on the origin and fate of trace emissions in the external combustion of gaseous hydrocarbons was undertaken in a collaborative effort between government, universities and industry. This collaborative project entitled the Petroleum Environmental Research Forum (PERF) Project 92-19 produced basic information and phenomenological understanding in two important areas, one basic and one applied. The specific objectives of the project were to measure emissions while operating different full-scale burners under various operating conditions and then to analyze the emission data to identify which operating conditions lead to low air toxic emissions. Another objective was to develop new chemical kinetic mechanisms and predictive models for the formation of air toxic species which would explain the origin and fate of these species in process heaters and industrial boilers. It was determined that a flame is a very effective reactor and that trace emissions from a typical gas-fired industry burner are very small. An unexpected finding was that trace emissions are not affected by hydrocarbon gaseous fuel composition, nor by the use of ultra low nitrous oxide burners. 2 refs., 8 figs.

  18. Urban farming as a possible source of trace metals in human diets

    Directory of Open Access Journals (Sweden)

    Joshua O. Olowoyo

    2016-02-01

    Full Text Available Rapid industrialisation and urbanisation have greatly increased the concentrations of trace metals as pollutants in the urban environment. These pollutants (trace metals are more likely to have an adverse effect on peri-urban agriculture which is now becoming a permanent feature of the landscape of many urban cities in the world. This review reports on the concentrations of trace metals in crops, including leafy vegetables harvested from different urban areas, thus highlighting the presence of trace metals in leafy vegetables. Various pathways of uptake of trace metals by leafy vegetables, such as the foliar and roots, and possible health risks associated with urban faming are discussed and various morphological and physiological impacts of trace metals in leafy vegetables are described. Defensive mechanisms and positive aspects of trace metals in plants are also highlighted.

  19. Nanomolar Trace Metal Analysis of Copper at Gold Microband Arrays

    Science.gov (United States)

    Wahl, A.; Dawson, K.; Sassiat, N.; Quinn, A. J.; O'Riordan, A.

    2011-08-01

    This paper describes the fabrication and electrochemical characterization of gold microband electrode arrays designated as a highly sensitive sensor for trace metal detection of copper in drinking water samples. Gold microband electrodes have been routinely fabricated by standard photolithographic methods. Electrochemical characterization were conducted in 0.1 M H2SO4 and found to display characteristic gold oxide formation and reduction peaks. The advantages of gold microband electrodes as trace metal sensors over currently used methods have been investigated by employing under potential deposition anodic stripping voltammetry (UPD-ASV) in Cu2+ nanomolar concentrations. Linear correlations were observed for increasing Cu2+ concentrations from which the concentration of an unknown sample of drinking water was estimated. The results obtained for the estimation of the unknown trace copper concentration in drinking was in good agreement with expected values.

  20. Nanomolar Trace Metal Analysis of Copper at Gold Microband Arrays

    International Nuclear Information System (INIS)

    Wahl, A; Dawson, K; Sassiat, N; Quinn, A J; O'Riordan, A

    2011-01-01

    This paper describes the fabrication and electrochemical characterization of gold microband electrode arrays designated as a highly sensitive sensor for trace metal detection of copper in drinking water samples. Gold microband electrodes have been routinely fabricated by standard photolithographic methods. Electrochemical characterization were conducted in 0.1 M H 2 SO 4 and found to display characteristic gold oxide formation and reduction peaks. The advantages of gold microband electrodes as trace metal sensors over currently used methods have been investigated by employing under potential deposition anodic stripping voltammetry (UPD-ASV) in Cu 2+ nanomolar concentrations. Linear correlations were observed for increasing Cu 2+ concentrations from which the concentration of an unknown sample of drinking water was estimated. The results obtained for the estimation of the unknown trace copper concentration in drinking was in good agreement with expected values.

  1. In situ quantification of ultra-low O2 concentrations in oxygen minimum zones

    DEFF Research Database (Denmark)

    Larsen, Morten; Lehner, Philipp; Borisov, Sergey M.

    2016-01-01

    based on the palladium(II)-benzoporphyrin luminophore, immobilized in a perfluorinated matrix with high O2 permeability. The trace sensor has a detection limit of ∼5 nmol L−1 with a dynamic range extending up to ∼2 μmol L−1. The sensor demonstrates a response time ..., and fully reversible response to hydrostatic pressure and temperature. The sensor showed excellent stability for continuously measurements during depth profiling in Oxygen Minimum Zones (OMZ). The novel sensor was deployed in situ using a Trace Oxygen Profiler instrument (TOP) equipped with two additional O...

  2. Spatial and seasonal variability of trace-element concentrations in sediments from the Santos-Cubatao estuarine system, Sao Paulo, Brazil

    International Nuclear Information System (INIS)

    Luiz-Silva, Wanilson; Matos, Rosa Helena Ribeiro; Kristosch, Giane Chaves; Machado, Wilson

    2006-01-01

    Multi-element analyses of sediment samples from the Santos-Cubatao Estuarine System were carried out to investigate the spatial and seasonal variability of trace-element concentrations. The study area contains a rich mangrove ecosystem that is a habitat for tens of thousands of resident and migratory birds, some of them endangered globally. Enrichments of metals in fine-grained surface sediments are, in decreasing order, Hg, Mn, La, Ca, Sr, Cd, Zn, Pb, Ba, Cu, Cr, Fe, Nb, Y, Ni and Ga, relative to pre-industrial background levels. The maximum enrichment ranged from 49 (Hg) to 3.1 (Ga). Mercury concentrations were greater in the Cubatao river than in other sites, while the other elements showed greater concentrations in the Morrao river. Concentrations of Mn were significantly greater in winter and autumn than in summer and spring. However, other elements (e.g. Cd and Pb) showed the opposite, with greater concentrations in summer and spring. This study suggests that seasonal changes in physical and chemical conditions may affect the degree of sediment enrichment and therefore make the assessment of contamination difficult. Consequently, these processes need to be considered when assessing water quality and the potential contamination of biota.(author)

  3. Determination and statistical analysis of trace element and active constituent concentrations in the medicinal plant Eucalyptus camaldulensis Dehnh (E. rostratus Schlecht)

    International Nuclear Information System (INIS)

    Kanias, G.D.; Kilikoglou, V.; Tsitsa, E.; Loukis, A.

    1993-01-01

    In the leaves of the medicinal plant Eucalyptus camaldulensis Dehnh (E. rostratus Schlecht) collected from different sampling areas of Greece the trace elements antimony, cesium, chromium, cobalt, iron, europium, rubidium scandium, strontium, thorium and zinc were determined by Instrumental Neutron Activation Analysis. In the same samples, the essential oil was determined by steam distillation and the percent relative composition of the essential oil in 1,8-cineole, p-cymene, α-pinene by gas liquid chromatography. Also the refractive index of the essential oil was determined by a refractometer. Statistical analysis included the calculation of the correlation coefficient. Multiple correlation and cluster analysis was applied to all analytical data. The results showed that the trace elements iron, chromium, cobalt and zinc are correlated with the variation of the concentration of essential oil in the examined plant. These four elements along with rubidium and essential oil content could be used for the separation of the samples into groups related to the sampling areas. Statistically significant correlation between active constituents and some trace elements and a linear negative correlation between 1,8-cineole and refractive index were found. (author) 13 refs.; 2 figs.; 2 tabs

  4. Trace element analysis of nail polishes

    International Nuclear Information System (INIS)

    Misra, G.; Mittal, V.K.; Sahota, H.S.

    1999-01-01

    Instrumental neutron activation analysis (INAA) technique was used to measure the concentrations of various trace elements in nail polishes of popular Indian and foreign brands. The aim of the present experiment was to see whether trace elements could distinguish nail polishes of different Indian and foreign brands from forensic point of view. It was found that cesium can act as a marker to differentiate foreign and Indian brands. (author)

  5. Characterization of Whey Protein Oil-In-Water Emulsions with Different Oil Concentrations Stabilized by Ultra-High Pressure Homogenization

    Directory of Open Access Journals (Sweden)

    Essam Hebishy

    2017-02-01

    Full Text Available In this study, the effect of ultra-high-pressure homogenization (UHPH: 100 or 200 MPa at 25 °C, in comparison to colloid mill (CM: 5000 rpm at 20 °C and conventional homogenization (CH: 15 MPa at 60 °C, on the stability of oil-in-water emulsions with different oil concentrations (10, 30 or 50 g/100 g emulsified by whey protein isolate (4 g/100 g was investigated. Emulsions were characterized for their microstructure, rheological properties, surface protein concentration (SPC, stability to creaming and oxidative stability under light (2000 lux/m2. UHPH produced emulsions containing lipid droplets in the sub-micron range (100–200 nm and with low protein concentrations on droplet surfaces. Droplet size (d3.2, µm was increased in CH and UHPH emulsions by increasing the oil concentration. CM emulsions exhibited Newtonian flow behaviour at all oil concentrations studied; however, the rheological behaviour of CH and UHPH emulsions varied from Newtonian flow (n ≈ 1 to shear-thinning (n ˂ 1 and thixotropic behaviour in emulsions containing 50% oil. This was confirmed by the non-significant differences in the d4.3 (µm value between the top and bottom of emulsions in tubes left at room temperature for nine days and also by a low migration velocity measured with a Turbiscan LAB instrument. UHPH emulsions showed significantly lower oxidation rates during 10 days storage in comparison to CM and CH emulsions as confirmed by hydroperoxides and thiobarbituric acid-reactive substances (TBARS. UHPH emulsions treated at 100 MPa were less oxidized than those treated at 200 MPa. The results from this study suggest that UHPH treatment generates emulsions that have a higher stability to creaming and lipid oxidation compared to colloid mill and conventional treatments.

  6. Cloud point extraction-flame atomic absorption spectrometry for pre-concentration and determination of trace amounts of silver ions in water samples

    Directory of Open Access Journals (Sweden)

    Xiupei Yang

    2017-03-01

    Full Text Available A cloud point extraction (CPE method was used as a pre-concentration strategy prior to the determination of trace levels of silver in water by flame atomic absorption spectrometry (FAAS The pre-concentration is based on the clouding phenomena of non-ionic surfactant, triton X-114, with Ag (I/diethyldithiocarbamate (DDTC complexes in which the latter is soluble in a micellar phase composed by the former. When the temperature increases above its cloud point, the Ag (I/DDTC complexes are extracted into the surfactant-rich phase. The factors affecting the extraction efficiency including pH of the aqueous solution, concentration of the DDTC, amount of the surfactant, incubation temperature and time were investigated and optimized. Under the optimal experimental conditions, no interference was observed for the determination of 100 ng·mL−1 Ag+ in the presence of various cations below their maximum concentrations allowed in this method, for instance, 50 μg·mL−1 for both Zn2+ and Cu2+, 80 μg·mL−1 for Pb2+, 1000 μg·mL−1 for Mn2+, and 100 μg·mL−1 for both Cd2+ and Ni2+. The calibration curve was linear in the range of 1–500 ng·mL−1 with a limit of detection (LOD at 0.3 ng·mL−1. The developed method was successfully applied for the determination of trace levels of silver in water samples such as river water and tap water.

  7. Factor analytical approaches for evaluating groundwater trace element chemistry data

    International Nuclear Information System (INIS)

    Farnham, I.M.; Johannesson, K.H.; Singh, A.K.; Hodge, V.F.; Stetzenbach, K.J.

    2003-01-01

    The multivariate statistical techniques principal component analysis (PCA), Q-mode factor analysis (QFA), and correspondence analysis (CA) were applied to a dataset containing trace element concentrations in groundwater samples collected from a number of wells located downgradient from the potential nuclear waste repository at Yucca Mountain, Nevada. PCA results reflect the similarities in the concentrations of trace elements in the water samples resulting from different geochemical processes. QFA results reflect similarities in the trace element compositions, whereas CA reflects similarities in the trace elements that are dominant in the waters relative to all other groundwater samples included in the dataset. These differences are mainly due to the ways in which data are preprocessed by each of the three methods. The highly concentrated, and thus possibly more mature (i.e. older), groundwaters are separated from the more dilute waters using principal component 1 (PC 1). PC 2, as well as dimension 1 of the CA results, describe differences in the trace element chemistry of the groundwaters resulting from the different aquifer materials through which they have flowed. Groundwaters thought to be representative of those flowing through an aquifer composed dominantly of volcanic rocks are characterized by elevated concentrations of Li, Be, Ge, Rb, Cs, and Ba, whereas those associated with an aquifer dominated by carbonate rocks exhibit greater concentrations of Ti, Ni, Sr, Rh, and Bi. PC 3, and to a lesser extent dimension 2 of the CA results, show a strong monotonic relationship with the percentage of As(III) in the groundwater suggesting that these multivariate statistical results reflect, in a qualitative sense, the oxidizing/reducing conditions within the groundwater. Groundwaters that are relatively more reducing exhibit greater concentrations of Mn, Cs, Co, Ba, Rb, and Be, and those that are more oxidizing are characterized by greater concentrations of V, Cr, Ga

  8. Ultra-trace determination of Strontium-90 in environmental soil samples from Qatar by collision/reaction cell-inductively coupled plasma mass spectrometry (CRC-ICP-MS/MS)

    Energy Technology Data Exchange (ETDEWEB)

    Al-Meer, S. H.; Amr, M. A. [Central Laboratories Unit, Qatar University, Doha (Qatar); Helal, A.I. [Atomic Energy Authority, Cairo (Egypt); Al-Kinani, A.T. [Minstery of Environment, Doha (Qatar)

    2013-07-01

    Because of the very low level of {sup 90}Sr in the environmental soil samples and its determination by beta counting may take several weeks, we developed a procedure for ultra-trace determination of {sup 90}Sr using collision reaction cell-inductively coupled plasma tandem mass spectrometry (CRC-ICP-MS/MS, Agilent 8800). Soil samples were dried at 105 deg. C and then heated in a furnace at 550 deg. C to remove any organics present. 500 g of each soil samples were aliquoted into 2000 ml glass beakers. Each Soils samples were soaked in 2 ppm Sr solution carrier to allow determination of chemical yield. The solid to liquid ratio was 1:1. Finally the soil samples were dried at 105 deg. C. Five hundred milliliters concentrated nitric acid and 250 ml hydrochloric acid volumes were added on 500 g soil samples. The samples were digested on hot plate at 80 deg. C to prevent spraying with continuous manual mixing. The leachate solution was separated. The solids were rinsed with 500 ml deionized water, warmed on a hot plate and the leachate plus previous leachate were filtered and the total volume was reduced to 500 ml by evaporation. Final leachate volume was transferred to a centrifuge tubes. The centrifuge tubes were centrifuged at 3,500 rpm for 10 min. The leachate was transferred to a 1 L beaker and heated on a hot plate to evaporate the leachate to dryness. The reside was re-dissolved in 100 ml of 2% HNO{sub 3} and reduced by evaporation to 10 mL. The solution was measured directly by CRC-ICP-MS/MS by setting the first quadruple analyzer to m/z 90 and introducing oxygen gas into the reaction cell for elimination isobar interference from zirconium-90. The method was validated by measurements of standard reference materials and applied on environmental soil samples. The overall time requirement for the measurement of strontium-90 by CRC-ICP-MS/MS is 2 days, significantly shorter than any radioanalytical protocol currently available. (authors)

  9. Influence of trace elements on fluoride uptake by teeth

    Energy Technology Data Exchange (ETDEWEB)

    Chaudhri, M A [Austin Hospital, Heidelberg (Australia). Dept. of Medical Physics; Melbourne Univ., Austin (Australia). Dept. of Medicine); Crawford, A [Melbourne Univ., Parkville (Australia). School of Physics

    1981-03-01

    To investigate the effect of various trace elements on fluoride uptake by teeth, the concentrations of F and other trace elements have been simultaneously determined in different regions of the teeth from children of South Australia. Teeth cross sectioned along the median plane have been used in these investigations, and their inside enamel, dentine and amelodentinal junctions investigated separately for the trace elemental composition. Fluoride has been determined by observing the 6-7 MeV gammas for the /sup 19/F(p,..cap alpha gamma..)/sup 16/O reaction, C by activation through the /sup 12/C(/sup 3/He,n)/sup 14/O reaction, while other trace elements have been measured by the thick target PIXE technique. Linear correlation coefficients have been calculated between the F concentrations in teeth and those of other trace elements observed. Fluoride is found to correlate best with C, Cu and Pb, poorly with Fe, Sr, Ni and Ag, while with Br and Zn it has-ve coefficients. Student's t-test has been applied to the data to examine the significance of the variation of Fand other trace elements amongst different dental tissues from healthy and diseased teeth.

  10. Characterization and mass balance of trace elements in an iron ore sinter plant

    Directory of Open Access Journals (Sweden)

    Lucas Ladeira Lau

    2016-04-01

    Full Text Available Environmental legislation is becoming more restrictive in several industrial sectors, especially in the steel industry, which is well known for its large pollution potential. With the recent growth of interest in effects of trace elements on the environment and health, the inclusion of emission limits on these elements in this legislation has become increasingly popular. This article aims to describe the partitioning of trace elements between the products (sinter and plant emissions in an iron ore sinter plant, aiming to better understand the behavior of these elements in the sintering process to eventually support interventions to modify these partitions. Chemical characterization of several sintering inputs was initially performed, revealing that the steel-making residues contained large concentrations of trace elements, whereas low concentrations were observed in the flux. Based on the trace element concentrations, we analyzed the injection of trace elements in a sintering pilot using a sintering mixture. Mass balance was then used to determine the theoretical partitioning of trace elements in the sinter and emissions; cadmium, nickel, lead, mercury, and copper exhibited greater tendencies to concentrate in atmospheric emissions.

  11. Enantioselective column coupled electrophoresis employing large bore capillaries hyphenated with tandem mass spectrometry for ultra-trace determination of chiral compounds in complex real samples.

    Science.gov (United States)

    Piešťanský, Juraj; Maráková, Katarína; Kovaľ, Marián; Havránek, Emil; Mikuš, Peter

    2015-12-01

    A new multidimensional analytical approach for the ultra-trace determination of target chiral compounds in unpretreated complex real samples was developed in this work. The proposed analytical system provided high orthogonality due to on-line combination of three different methods (separation mechanisms), i.e. (1) isotachophoresis (ITP), (2) chiral capillary zone electrophoresis (chiral CZE), and (3) triple quadrupole mass spectrometry (QqQ MS). The ITP step, performed in a large bore capillary (800 μm), was utilized for the effective sample pretreatment (preconcentration and matrix clean-up) in a large injection volume (1-10 μL) enabling to obtain as low as ca. 80 pg/mL limits of detection for the target enantiomers in urine matrices. In the chiral CZE step, the different chiral selectors (neutral, ionizable, and permanently charged cyclodextrins) and buffer systems were tested in terms of enantioselectivity and influence on the MS detection response. The performance parameters of the optimized ITP - chiral CZE-QqQ MS method were evaluated according to the FDA guidance for bioanalytical method validation. Successful validation and application (enantioselective monitoring of renally eliminated pheniramine and its metabolite in human urine) highlighted great potential of this chiral approach in advanced enantioselective biomedical applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Portoan Ultra Group Members’ Social Representation of Lisbon and Sport Lisboa and Benfica and Its Influence on the Discourses and Practices of the Portoan Ultra Groups and Their Members

    Directory of Open Access Journals (Sweden)

    Seabra Daniel

    2017-03-01

    Full Text Available The following text relates to a more recent approach to the problem of hooliganism and the Ultra Movement. It does not focus on a broad theory aimed to explain these two phenomena, but rather concentrates on the use of concepts that are relevant for a multifaceted understanding of them. Therefore, this text is the result of an investigation carried out on the four Ultra groups who support clubs in Oporto.

  13. Etude de la concentration des métaux traces chez (muricidae) le long du littoral Tunisien

    OpenAIRE

    Chouba, L.; Tissaoui, Ch.; El Abed, A.

    2008-01-01

    La Tunisie dispose d’une ressource importante en coquillages, plusieurs espèces sont commercialisées et elles ont fait l’objet de programmes de qualité pour la sauvegarde de la santé humaine. Dans ce contexte, nous avons réalisé un suivi saisonnier de la concentration de trois métaux traces toxiques, le cadmium (Cd), le plomb (Pb), et le mercure (Hg) dans la totalité de la masse molle, dans le pied et dans les viscères d’un Mollusque Gastéropode, l’Hexaplex trunculus communément appelé en Tun...

  14. Distributions of traces of metals on sorption from solutions of vanadium(V)

    International Nuclear Information System (INIS)

    Evseeva, N.K.; Turnaov, A.N.; Telegin, G.F.; Kremenskaya, I.N.

    1983-01-01

    A study is made of the distributions of traces of metals between aqueous solutions of vanadium(V) and a solid reagent made by introducing di-2-ethylhexylphosphoric acid into an inert matrix: a nonionic macroporous copolymer of polystyrene with divinyl benzene (wofatit Y 29). As regards degree of extraction, the trace components fall in the series zinc > cadmium > manganese > copper > cobalt, which resemble the extractability series. The vanadium content of the solution and the concentrations of the trace components have virtually no effect on the sorption. The process is effective in concentrating trace components from solutions containing vanadium(V)

  15. Trace elements in groundwater used for water supply in Latvia

    Science.gov (United States)

    Retike, Inga; Kalvans, Andis; Babre, Alise; Kalvane, Gunta; Popovs, Konrads

    2014-05-01

    Latvia is rich with groundwater resources of various chemical composition and groundwater is the main drinking source. Groundwater quality can be easily affected by pollution or overexploitation, therefore drinking water quality is an issue of high importance. Here the first attempt is made to evaluate the vast data base of trace element concentrations in groundwater collected by Latvian Environment, Geology and Meteorology Centre. Data sources here range from National monitoring programs to groundwater resources prospecting and research projects. First available historical records are from early 1960, whose quality is impossible to test. More recent systematic research has been focused on the agricultural impact on groundwater quality (Levins and Gosk, 2007). This research was mainly limited to Quaternary aquifer. Monitoring of trace elements arsenic, cadmium and lead was included in National groundwater monitoring program of Latvia in 2008 and 2009, but due to lack of funding the monitoring was suspended until 2013. As a result there are no comprehensive baseline studies regarding the trace elements concentration in groundwater. The aim of this study is to determine natural major and trace element concentration in aquifers mainly used for water supply in Latvia and to compare the results with EU potable water standards. A new overview of artesian groundwater quality will be useful for national and regional planning documents. Initial few characteristic traits of trace element concentration have been identified. For example, elevated fluorine, strontium and lithium content can be mainly associated with gypsum dissolution, but the highest barium concentrations are found in groundwaters with low sulphate content. The groundwater composition data including trace element concentrations originating from heterogeneous sources will be processed and analyzed as a part of a newly developed geologic and hydrogeological data management and modeling system with working name

  16. The spectrographic determination of minor and trace elements in copper, lead, and zinc concentrates

    International Nuclear Information System (INIS)

    Breckenridge, R.L.; Russell, G.M.; Watson, A.E.

    1976-01-01

    This report deals with the development of a method for the determination, by an emission-spectrographic technique, of magnesium, manganese, aluminium, silver, calcium, chromium, cobalt, titanium, antimony, cadmium, molybdenum, zirconium, nickel, boron, vanadium, arsenic, beryllium, tin, germanium, and bismuth in copper, lead, and zinc sulphide concentrates. The method involves the preparation of complex standards in which the volatile elements arsenic, antimony, cadmium, tin, and bismuth are incorporated as sulphide compounds at temperatures of 800 degrees Celsius in evacuated silica tubes together with a synthetic sulphide matrix. These standards are then mixed with the other minor and trace elements to form composite standards. The conditions for excitation with a direct-current arc, and the analytical lines for the elements and internal standards, are given. The procedure is rapid and convenient, and involves the minimum of sample preparation. The accuracy is about 10 per cent, and the method has a coefficient of variation for the various elements of between 2 and 13 per cent

  17. A Comparative Analyses of Granulometry, Mineral Composition and Major and Trace Element Concentrations in Soils Commonly Ingested by Humans

    Directory of Open Access Journals (Sweden)

    Veronica M. Ngole-Jeme

    2015-07-01

    Full Text Available This study compared the granulometric properties, mineralogical composition and concentrations of major and trace element oxides of commonly ingested soils (geophagic soil collected from different countries with a view of understanding how varied they may be in these properties and to understand the possible health implications of ingesting them. Soil samples were collected from three different countries (South Africa, Swaziland and Democratic Republic of Congo (DRC and their granulometric properties, concentrations of major and trace element oxides as well as mineralogical composition determined. Differences were observed in the granulometric properties of geophagic soil from the three different countries with most of them having <20% clay content. The soils also showed varied degrees of weathering with values of Chemical Index of Alteration (CIA and Chemical Index of Weathering (CIW being between 60% and 99.9% respectively. The mineral assemblages of the soils from South Africa and Swaziland were dominated by the primary minerals quartz and feldspar whereas soils from DRC had more of kaolinite, a secondary mineral than primary minerals. Soils from DRC were associated with silt, clay, Al2O3, and CIA unlike most samples from South Africa which were associated with SiO2, sand, K2O, CaO, and MgO. The soils from Swaziland were closely associated with silt, H2O and Fe2O3(t. These associations reflect the mineralogy of the samples. These soils are not likely to serve as nutrient supplements because of the low concentrations of the nutrient elements contained. The coarse texture of the samples may also result in dental destruction during mastication. Sieving of the soils before ingestion to remove coarse particles is recommended to reduce the potential health threat associated with the ingestion of coarse-textured soils.

  18. A Comparative Analyses of Granulometry, Mineral Composition and Major and Trace Element Concentrations in Soils Commonly Ingested by Humans

    Science.gov (United States)

    Ngole-Jeme, Veronica M.; Ekosse, Georges-Ivo E.

    2015-01-01

    This study compared the granulometric properties, mineralogical composition and concentrations of major and trace element oxides of commonly ingested soils (geophagic soil) collected from different countries with a view of understanding how varied they may be in these properties and to understand the possible health implications of ingesting them. Soil samples were collected from three different countries (South Africa, Swaziland and Democratic Republic of Congo (DRC)) and their granulometric properties, concentrations of major and trace element oxides as well as mineralogical composition determined. Differences were observed in the granulometric properties of geophagic soil from the three different countries with most of them having soils also showed varied degrees of weathering with values of Chemical Index of Alteration (CIA) and Chemical Index of Weathering (CIW) being between 60% and 99.9% respectively. The mineral assemblages of the soils from South Africa and Swaziland were dominated by the primary minerals quartz and feldspar whereas soils from DRC had more of kaolinite, a secondary mineral than primary minerals. Soils from DRC were associated with silt, clay, Al2O3, and CIA unlike most samples from South Africa which were associated with SiO2, sand, K2O, CaO, and MgO. The soils from Swaziland were closely associated with silt, H2O and Fe2O3(t). These associations reflect the mineralogy of the samples. These soils are not likely to serve as nutrient supplements because of the low concentrations of the nutrient elements contained. The coarse texture of the samples may also result in dental destruction during mastication. Sieving of the soils before ingestion to remove coarse particles is recommended to reduce the potential health threat associated with the ingestion of coarse-textured soils. PMID:26264010

  19. Selected trace elements in Stockton, New Zealand, waters

    International Nuclear Information System (INIS)

    Alarcon Leon, E.; Anstiss, R.G.

    2002-01-01

    Ni, Mn, As, Pb, Cd, Cr, Cu, Hg, Se, Al, Zn, Fe, SO 4 2- , hardness (calc.) in addition to pH, total dissolved solids (TDS), and total suspended solids (TSS) were measured at 18 (11 surface and 7 subsurface) sampling sites (which were each assigned a semi-quantitative Mudstone Index (MI)) from 20 days over 9 months in the waters which drain the Stockton coal mine area on the Stockton Plateau, New Zealand. Trace element, TDS and TSS concentrations were found to be elevated and pH depressed consistent with acid mine drainage (AMD) and were characterised by significant variability due to environmental processes. Frequent concentration spikes in surface and subsurface waters occurred which sometimes exceeded maximum acceptable values (MAV) and/or aesthetic guideline values (GV) including a number of toxic trace elements. Mean concentrations of Ni and Mn in both surface and subsurface waters and As and Cd in subsurface waters exceeded MAVs. Mean concentrations of Mn, Al, Fe, SO 4 2- , and pH in both surface and subsurface waters exceeded GVs. There tends to be higher trace element and TDS concentrations where there are more mudstones (higher MI) with lower pHs. It is recommended that any further studies focus on geographic distribution, concentration fluctuation factors, movement, and possible exposure issues. (author). 7 refs., 1 fig., 3 tabs

  20. Trace elements and radon in groundwater across the United States, 1992-2003

    Science.gov (United States)

    Ayotte, Joseph D.; Gronberg, Jo Ann M.; Apodaca, Lori E.

    2011-01-01

    Trace-element concentrations in groundwater were evaluated for samples collected between 1992 and 2003 from aquifers across the United States as part of the U.S. Geological Survey National Water-Quality Assessment Program. This study describes the first comprehensive analysis of those data by assessing occurrence (concentrations above analytical reporting levels) and by comparing concentrations to human-health benchmarks (HHBs). Data from 5,183 monitoring and drinking-water wells representing more than 40 principal and other aquifers in humid and dry regions and in various land-use settings were used in the analysis. Trace elements measured include aluminum (Al), antimony (Sb), arsenic (As), barium (Ba), beryllium (Be), boron (B), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (Pb), lithium (Li), manganese (Mn), molybdenum (Mo), nickel (Ni), selenium (Se), silver (Ag), strontium (Sr), thallium (Tl), uranium (U), vanadium (V), and zinc (Zn). Radon (Rn) gas also was measured and is included in the data analysis. Climate influenced the occurrence and distribution of trace elements in groundwater whereby more trace elements occurred and were found at greater concentrations in wells in drier regions of the United States than in humid regions. In particular, the concentrations of As, Ba, B, Cr, Cu, Mo, Ni, Se, Sr, U, V, and Zn were greater in the drier regions, where processes such as chemical evolution, ion complexation, evaporative concentration, and redox (oxidation-reduction) controls act to varying degrees to mobilize these elements. Al, Co, Fe, Pb, and Mn concentrations in groundwater were greater in humid regions of the United States than in dry regions, partly in response to lower groundwater pH and (or) more frequent anoxic conditions. In groundwater from humid regions, concentrations of Cu, Pb, Rn, and Zn were significantly greater in drinking-water wells than in monitoring wells. Samples from drinking-water wells in dry regions had

  1. Oesophageal cancer in the Transkei. Determination of trace element concentrations in selected plant material by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Renan, M.J.; Drennan, B.D.; Keddy, R.J.; Sellschop, J.P.F.

    1979-01-01

    The results of the analysis by instrumental neutron activation for the concentration of trace elements in plant materials from certain areas in the Transkei region of southern Africa are presented. These areas are selected for their characteristic high or low incidence of carcinoma of the oesophagus. To broaden the suite of elements for which analysed and to overcome some of the limitations of neutron activation analysis, certain other nuclear analyses and methods are suggested which, if utilized, would increase the number of elements determined, and so improve the information available. (author)

  2. Analysis of trace metals in various brands of cigarettes

    International Nuclear Information System (INIS)

    Iqbal, M.

    1996-01-01

    The present work deals with the analysis of trace metals in various brands of cigarettes belonging to four different countries. In the present research seven trace elements have been determined spectrophotometrically by the use of suitable analytical reagent of the respective metal ions. The metals which has been analysed quantitatively in forty one brand of cigarettes are aluminium, copper, chromium, nickel, iron titanium and zinc. The concentration per cigarette of these metals are in tolerable range. The concentration of above mentioned metal ions is highest in Pakistani cigarettes tobacco while the concentration of nickel is highest in American cigarettes. (author) 221 refs

  3. Composition of bracken: some major- and trace-element constituents

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, J G

    1953-01-01

    Periodic samples of bracken taken during the growing season have shown that the concentration of major elements (except calcium and sodium) decreases with age in fronds, and remains relatively constant in rhizomes, whereas trace-element concentration varies widely. Soil type has little effect on the mineral composition of fronds. Examination of three rhizome types revealed no wide differences in the content of major elements; pinnules generally contained higher concentrations of major and trace elements than fronds. Comparison of results with those published elsewhere for moorland plants grown under similar conditions indicates that bracken contains more potassium and less molybdenum.

  4. Determination of trace elements in chicken feeds in Khartoum state

    International Nuclear Information System (INIS)

    Hassan, Salma Yahya Mohammed

    2017-03-01

    Trace elements are very important for chicken because thy contribute in biochemical processes required for normal growth, development and formation of the eggshell. The deficiency or the elevation of these trace elements may affect the normal physiological activity and biochemical process of their bodies. In this study the concentrations of trace elements in chicken feed samples were determined by X RF spectrometry. The results showed that there were 9 trace elements in sample ( K, Ca Mn, Fe Cu Zn, Pb, Rb, Sr) the mean concentration were K ( 2.12 x 10 4 ), Ca (2.22x10 4 ), Mn (48.1). Fe (191), Cu(9.81), Zn (24.6), Pb (1.63), Rb (7.79), Sr(4.09) ppm. Comparing the trace elements concentrations obtained in this study with the recommended values showed that some of them e.g Mn, Cu, Zn, Fe were found higher concentration than the recommended values, which stipulated by national research council NRC European Union. While lead concentration was in the permissible limit (5mg/kg). However, the statistical Alan's revealed than there were no significant difference between all concentrations of trace elements in the two types of chicken feeds i.e layer and broiler. The pearson correlation test displayed a strong correlation between K-Rb (0.885), Mn-Zn (0.874). The negative correlation between Mn-Rb (0.680), K-Mn (0.6000), K-Ca (0.565), Zn-Rb (-0.541). Ca-Rb (0.458) were found . Further investigations were performed using the principal component analysis (PCA) which involved the extraction of principal factor to study the total variance in the feed samples in terms of the trace elements concentrations in each. The obtained results revealed that the first principal component have a positive correlation with the elements Ca, Mn, Pb, and Zn, while K and Rb showed negative correlation with it. Similarly, the second principal compound showed positive correlation with the elements Mn, PB and Zn, while Ca and Sr showed negative, on the perth hand the third component was found to

  5. Trace element contamination in feather and tissue samples from Anna’s hummingbirds

    Science.gov (United States)

    Mikoni, Nicole A.; Poppenga, Robert H.; Ackerman, Joshua T.; Foley, Janet E.; Hazlehurst, Jenny; Purdin, Güthrum; Aston, Linda; Hargrave, Sabine; Jelks, Karen; Tell, Lisa A.

    2017-01-01

    Trace element contamination (17 elements; Be, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Mo, Cd, Ba, Hg, Tl, and Pb) of live (feather samples only) and deceased (feather and tissue samples) Anna's hummingbirds (Calypte anna) was evaluated. Samples were analyzed using inductively coupled plasma-mass spectrometry (ICP-MS; 17 elements) and atomic absorption spectrophotometry (Hg only). Mean plus one standard deviation (SD) was considered the benchmark, and concentrations above the mean + 1 SD were considered elevated above normal. Contour feathers were sampled from live birds of varying age, sex, and California locations. In order to reduce thermal impacts, minimal feathers were taken from live birds, therefore a novel method was developed for preparation of low mass feather samples for ICP-MS analysis. The study found that the novel feather preparation method enabled small mass feather samples to be analyzed for trace elements using ICP-MS. For feather samples from live birds, all trace elements, with the exception of beryllium, had concentrations above the mean + 1 SD. Important risk factors for elevated trace element concentrations in feathers of live birds were age for iron, zinc, and arsenic, and location for iron, manganese, zinc, and selenium. For samples from deceased birds, ICP-MS results from body and tail feathers were correlated for Fe, Zn, and Pb, and feather concentrations were correlated with renal (Fe, Zn, Pb) or hepatic (Hg) tissue concentrations. Results for AA spectrophotometry analyzed samples from deceased birds further supported the ICP-MS findings where a strong correlation between mercury concentrations in feather and tissue (pectoral muscle) samples was found. These study results support that sampling feathers from live free-ranging hummingbirds might be a useful, non-lethal sampling method for evaluating trace element exposure and provides a sampling alternative since their small body size limits traditional sampling of blood and tissues. The

  6. Trace element analysis in the serum and hair of Antarctic leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Rachael [Faculty of Veterinary Science, University of Sydney, NSW 2006 Australia (Australia); Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia)], E-mail: rgray@vetsci.usyd.edu.au; Canfield, Paul [Faculty of Veterinary Science, University of Sydney, NSW 2006 (Australia); Rogers, Tracey [Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia); Evolution and Ecology Research Centre and School of Biological Earth and Environmental Sciences, University of New South Wales, NSW 2052 (Australia)

    2008-07-25

    Leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii, occupy an upper trophic level within the Antarctic ecosystem and are useful indicator species in the Southern Ocean of trace element concentrations. Reference values for the concentration of 19 trace elements were determined in the serum and hair of leopard and Weddell seals sampled in Eastern Antarctica. These reference values can be used as 'baseline' levels for monitoring trace element concentrations in these species. Greater trace element concentrations were determined in hair compared to serum, indicating different time scales of trace element accumulation in these samples. For the majority of trace elements, except for Se in the leopard seal samples and Cr in the Weddell seal samples, significant regression relationships for trace element concentrations in hair and serum were not elucidated. Significant differences were determined in the concentrations of seven out of 15 elements with hair type, moult and new, in the leopard seal; concentrations in moult hair were determined to be greater than in new hair for all elements except Zn. Hair analysis was determined to be useful for monitoring exposure to trace elements and when collected off the ice from moulting seals, hair can be employed as a non-invasive sample for trace element analysis in leopard and Weddell seals.

  7. Phytoaccumulation of trace elements by wetland plants: 3. Uptake and accumulation of ten trace elements by twelve plant species

    Energy Technology Data Exchange (ETDEWEB)

    Qian, J.H.; Zayed, A.; Zhu, Y.L.; Yu, M.; Terry, N.

    1999-10-01

    Interest is increasing in using wetland plants in constructed wetlands to remove toxic elements from polluted wastewater. To identify those wetland plants that hyperaccumulate trace elements, 12 plant species were tested for their efficiency to bioconcentrate 10 potentially toxic trace elements including As, b, Cd, Cr, Cu, Pb, Mn, Hg, Ni, and Se. Individual plants were grown under carefully controlled conditions and supplied with 1 mg L{sup {minus}1} of each trace element individually for 10 d. Except B, all elements accumulated to much higher concentrations in roots than in shoots. Highest shoot tissue concentrations (mg kg{sup {minus}1} DW) of the various trace elements were attained by the following species: umbrella plant (Cyperus alternifolius L.) for Mn (198) and Cr (44); water zinnia (Wedelia trilobata Hitchc.) for Cd (148) and Ni (80); smartweed (Polygonum hydropiperoides Michx.) for Cu (95) and Pb (64); water lettuce (Pistia stratiotes L.) for Hg (92), As (34), and Se (39); and mare's tail (hippuris vulgaris L.) for B (1132). Whereas, the following species attained the highest root tissue concentrations (mg kg{sup {minus}1} DW); stripped rush (Baumia rubiginosa) for Mn (1683); parrot's feather (Myriophyllum brasiliense Camb.) for Cd (1426) and Ni (1077); water lettuce for Cu (1038), Hg (1217), and As (177); smartweed for Cr (2980) and Pb (1882); mare's tail for B (1277); and monkey flower (Mimulus guttatus Fisch.) for Se (384). From a phytoremediation perspective, smartweed was probably the best plant species for trace element removal from wastewater due to its faster growth and higher plant density.

  8. Trace elements in precious and common opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1997-01-01

    Neutron activation analysis (NAA) was used to determine the concentration of trace elements in 44 precious and 52 common opals sampled from a number of recognised fields within Australia. The purpose of this study was to determine if precious and common opals of the same colour and location have the same or a different trace element profile. Similar numbers of black, white and grey samples were studied in each case. In most cases, common opals had a significantly higher concentration of certain trace elements when compared with precious opals. (author)

  9. Biodiesel as a lubricity additive for ultra low sulfur diesel

    Directory of Open Access Journals (Sweden)

    Subongkoj Topaiboul1 and 2,*

    2010-05-01

    Full Text Available With the worldwide trend to reduce emission from diesel engines, ultra low sulfur diesel has been introduced with thesulfur concentration of less than 10 ppm. Unfortunately, the desulfurization process inevitably reduces the lubricity of dieselfuel significantly. Alternatively, biodiesel, with almost zero sulfur content, has been added to enhance lubricity in an ultralow sulfur diesel. This work has evaluated the effectiveness of the biodiesel amount, sourced from palm and jatropha oil,and origin in ultra low sulfur diesel locally available in the market. Wear scar from a high-frequency reciprocating rig isbenchmarked to the standard value (460 m of diesel fuel lubricity. It was found that very small amount (less than 1% ofbiodiesel from either source significantly improves the lubricity in ultra low sulfur diesel, and the biodiesel from jatropha oilis a superior lubricity enhancer.

  10. Inductively coupled plasma – Tandem mass spectrometry (ICP-MS/MS): A powerful and universal tool for the interference-free determination of (ultra)trace elements – A tutorial review

    Energy Technology Data Exchange (ETDEWEB)

    Balcaen, Lieve; Bolea-Fernandez, Eduardo [Ghent University, Department of Analytical Chemistry, Krijgslaan 281-S12, B-9000 Ghent (Belgium); Resano, Martín [University of Zaragoza, Department of Analytical Chemistry, Pedro Cerbuna 12, E-50009 Zaragoza (Spain); Vanhaecke, Frank, E-mail: Frank.Vanhaecke@UGent.be [Ghent University, Department of Analytical Chemistry, Krijgslaan 281-S12, B-9000 Ghent (Belgium)

    2015-09-24

    This paper is intended as a tutorial review on the use of inductively coupled plasma – tandem mass spectrometry (ICP-MS/MS) for the interference-free quantitative determination and isotope ratio analysis of metals and metalloids in different sample types. Attention is devoted both to the instrumentation and to some specific tools and procedures available for advanced method development. Next to the more typical reaction gases, e.g., H{sub 2}, O{sub 2} and NH{sub 3}, also the use of promising alternative gases, such as CH{sub 3}F, is covered, and the possible reaction pathways with those reactive gases are discussed. A variety of published applications relying on the use of ICP-MS/MS are described, to illustrate the added value of tandem mass spectrometry in (ultra)trace analysis. - Highlights: • First review on tandem ICP-mass spectrometry (ICP-MS/MS). • Clear description of operating principles of ICP-MS/MS. • Description on how to make use of product ion scans, precursor ion scans and neutral gain scans in method development. • Overview of applications published so far.

  11. Inductively coupled plasma – Tandem mass spectrometry (ICP-MS/MS): A powerful and universal tool for the interference-free determination of (ultra)trace elements – A tutorial review

    International Nuclear Information System (INIS)

    Balcaen, Lieve; Bolea-Fernandez, Eduardo; Resano, Martín; Vanhaecke, Frank

    2015-01-01

    This paper is intended as a tutorial review on the use of inductively coupled plasma – tandem mass spectrometry (ICP-MS/MS) for the interference-free quantitative determination and isotope ratio analysis of metals and metalloids in different sample types. Attention is devoted both to the instrumentation and to some specific tools and procedures available for advanced method development. Next to the more typical reaction gases, e.g., H_2, O_2 and NH_3, also the use of promising alternative gases, such as CH_3F, is covered, and the possible reaction pathways with those reactive gases are discussed. A variety of published applications relying on the use of ICP-MS/MS are described, to illustrate the added value of tandem mass spectrometry in (ultra)trace analysis. - Highlights: • First review on tandem ICP-mass spectrometry (ICP-MS/MS). • Clear description of operating principles of ICP-MS/MS. • Description on how to make use of product ion scans, precursor ion scans and neutral gain scans in method development. • Overview of applications published so far.

  12. Impact of superplasticizer concentration and of ultra-fine particles on the rheological behaviour of dense mortar suspensions

    International Nuclear Information System (INIS)

    Artelt, C.; Garcia, E.

    2008-01-01

    This work aims at investigating the impact of the addition of superplasticizer and of ultra-fine particles, namely of silica fume and of precipitated titania, on the rheological behaviour of water-lean mortar pastes. The pastes are characterised in terms of their spread, their flowing behaviour and by means of performing a shear test, giving access to viscosity/shear gradient correlations. Adding superplasticizer is shown to shift the onset of shear thickening of the referring pastes to higher shear rates and to attenuate its otherwise rapid evolution, possibly by means of favouring steric particle-particle interactions. The workability of these mortars, which is characterised in terms of spread values and draining, is also improved. For the case of fly ash based mortars, adding ultra-fine particles is another way of (slightly) 'retarding' shear thickening and of attenuating its evolution, possibly because of resulting in - on the average - lower hydrodynamic forces and reduced attractive Van der Waals interactions between particles. However, at the same time these mortars are characterised by a worsening in workability which is attributed to the huge amount of surface area provided by the ultra-fines

  13. O-Ring sealing arrangements for ultra-high vacuum systems

    Science.gov (United States)

    Kim, Chang-Kyo; Flaherty, Robert

    1981-01-01

    An all metal reusable O-ring sealing arrangement for sealing two concentric tubes in an ultra-high vacuum system. An O-ring of a heat recoverable alloy such as Nitinol is concentrically positioned between protruding sealing rings of the concentric tubes. The O-ring is installed between the tubes while in a stressed martensitic state and is made to undergo a thermally induced transformation to an austenitic state. During the transformation the O-ring expands outwardly and contracts inwardly toward a previously sized austenitic configuration, thereby sealing against the protruding sealing rings of the concentric tubes.

  14. Trace element emissions from coal

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-09-15

    Trace elements are emitted during coal combustion. The quantity, in general, depends on the physical and chemical properties of the element itself, the concentration of the element in the coal, the combustion conditions and the type of particulate control device used, and its collection efficiency as a function of particle size. Some trace elements become concentrated in certain particle streams following combustion such as bottom ash, fly ash, and flue gas particulate matter, while others do not. Various classification schemes have been developed to describe this partitioning behaviour. These classification schemes generally distinguish between: Class 1: elements that are approximately equally concentrated in the fly ash and bottom ash, or show little or no fine particle enrichment, examples include Mn, Be, Co and Cr; Class 2: elements that are enriched in the fly ash relative to bottom ash, or show increasing enrichment with decreasing particle size, examples include As, Cd, Pb and Sb; Class 3: elements which are emitted in the gas phase (primarily Hg (not discussed in this review), and in some cases, Se). Control of class 1 trace elements is directly related to control of total particulate matter emissions, while control of the class 2 elements depends on collection of fine particulates. Due to the variability in particulate control device efficiencies, emission rates of these elements can vary substantially. The volatility of class 3 elements means that particulate controls have only a limited impact on the emissions of these elements.

  15. Effects of trace element concentration on enzyme controlled stable isotope fractionation during aerobic biodegradation of toluene.

    Science.gov (United States)

    Mancini, Silvia A; Hirschorn, Sarah K; Elsner, Martin; Lacrampe-Couloume, Georges; Sleep, Brent E; Edwards, Elizabeth A; Lollar, Barbara Sherwood

    2006-12-15

    The effects of iron concentration on carbon and hydrogen isotopic fractionation during aerobic biodegradation of toluene by Pseudomonas putida mt-2 were investigated using a low iron medium and two different high iron media. Mean carbon enrichment factors (epsilonc) determined using a Rayleigh isotopic model were smaller in culture grown under high iron conditions (epsilonc = -1.7+/-0.1%) compared to low iron conditions (epsilonc = -2.5+/-0.3%). Mean hydrogen enrichment factors (epsilonH) were also significantly smaller for culture grown under high iron conditions (epsilonH = -77 +/-4%) versus low iron conditions (EpsilonH = -159+/-11%). A mechanistic model for enzyme kinetics was used to relate differences in the magnitude of isotopic fractionation for low iron versus high iron cultures to the efficiency of the enzymatic transformation. The increase of carbon and hydrogen enrichment factors at low iron concentrations suggests a slower enzyme-catalyzed substrate conversion step (k2) relative to the enzyme-substrate binding step (k-l) at low iron concentration. While the observed differences were subtle and, hence, do not significantly impact the ability to use stable isotope analysis in the field, these results demonstrated that resolvable differences in carbon and hydrogen isotopic fractionation were related to low and high iron conditions. This novel result highlights the need to further investigate the effects of other trace elements known to be key components of biodegradative enzymes.

  16. The influence of intestine-based treatment using Xuan Bai Cheng Qi Tang on the concentration of trace elements in the main organs of COPD rats

    Directory of Open Access Journals (Sweden)

    Jiamin Yang

    2017-01-01

    Conclusion: This study showed that “treating from the intestine” using Xuan Bai Cheng Qi Tang and its modified formulae can regulate the concentration of trace elements in the main organs of COPD rats. This may be one of the mechanisms for intestine-based treatment for COPD.

  17. Limitation of productivity by trace metals in the sea

    International Nuclear Information System (INIS)

    Morel, F.M.M.; Price, N.M.; Hudson, R.J.M.

    1991-01-01

    Some trace metals such as Fe, Ni, Cu, and Zn are essential for the growth of phytoplankton. The concentrations of these essential trace elements in seawater are so low as to limit their availability to aquatic microbiota. Trace element uptake is ultimately limited by kinetics of reaction with transport ligands or by diffusion to the cell. From what the authors know of the characteristics of the uptake systems of phytoplankton and their trace metal requirements they can estimate that Fe and Zn may at some times in some place limit phytoplankton productivity, which is in accord with available field data on trace metal enrichments

  18. Flame atomic absorption spectrometric determination of trace quantities of cadmium in water samples after cloud point extraction in Triton X-114 without added chelating agents

    International Nuclear Information System (INIS)

    Afkhami, Abbas; Madrakian, Tayyebeh; Siampour, Hajar

    2006-01-01

    A new micell-mediated phase separation method for preconcentration of ultra-trace quantities of cadmium as a prior step to its determination by flame atomic absorption spectrometry has been developed. The method is based on the cloud point extraction (CPE) of cadmium in iodide media with Triton X-114 in the absence of any chelating agent. The optimal extraction and reaction conditions (e.g., acid concentration, iodide concentration, effect of time) were studied, and the analytical characteristics of the method (e.g., limit of detection, linear range, preconcentration, and improvement factors) were obtained. Linearity was obeyed in the range of 3-300 ng mL -1 of cadmium. The detection limit of the method is 1.0 ng mL -1 of cadmium. The interference effect of some anions and cations was also tested. The method was applied to the determination of cadmium in tap water, waste water, and sea water samples

  19. Trace element distribution in different chemical fractions of False Bay sediments

    International Nuclear Information System (INIS)

    Rosental, R.

    1984-05-01

    Trace metals in the aquatic environment are generally concentrated on solid geochemical phases which eventually become incorporated into estuarine and marine sediments. The mechanism of trace metal concentration is believed to be adsorption on various geochemical phases, such as hydrous metal oxides, clays and organic matter. Metals in estuarine sediments can thus be expected to be partitioned between different phases, depending on the concentration of the phase and the strength of the adsorption bond. The bioavailability of sediment-bound metals to deposit-feeding organisms will depend on trace metal partitioning and the kinetics of biological metal uptake from each geochemical phase. The major objective of this study was to establish an analytical procedure involving sequential chemical extractions for the partitioning of particulate trace metals in sediment samples, collected from False Bay. Eight metals were examined, i.e. Cd, Cu, Cr, Fe, Mn, Ni, Pb and Zn. X-ray diffraction was also used in the study

  20. Reassessment of 239Pu on planchets from human urine samples at ultra-trace levels using Aridus-ICP-SFMS and AMS

    International Nuclear Information System (INIS)

    Hernandez-Mendoza, H.; Chamizo, E.; Delgado, A.; Garcia-Leon, M.; Yllera, A.

    2012-01-01

    New analytical methods developed at the facilities here, based on two ultra-sensitive mass spectrometry (MS) techniques, inductively coupled plasma sector field mass spectrometer with a desolvator system (Aridus-ICP-SFMS) and accelerator MS (AMS), have been applied in this work for the reassessment of 239 Pu in alpha spectrometry (AS) planchets corresponding to spiked human urine samples. The obtained 239 Pu minimum detectable activities (MDAs) values by Aridus-ICP-SFMS and AMS were 3 fg (∼6.92 μBq) and 0.4 fg (∼0.92 μBq), respectively, per sample, which are much better than those attainable by AS [50 fg (∼115.3 μBq) of 239 Pu per sample, approximately]. Therefore, it is demonstrated that the MS techniques employed in this work are very powerful tools for internal dosimetry studies in human urine samples, giving excellent results when the reassessment of AS planchets is needed (samples with a Pu concentration below or at the MDA levels measurable by AS). This work is the continuation of an article published in J. Anal. At. Spectrom. 25 (1410-1415) 2010. (authors)

  1. Brain trace elements and aging

    International Nuclear Information System (INIS)

    Hebbrecht, Geert; Maenhaut, Willy; Reuck, Jacques de

    1999-01-01

    Degenerative mechanisms involved in the aging process of the brain are to a certain extent counteracted by repair mechanisms. In both degenerative and recovery processes, trace elements are involved. The present study focused on the role of two minor (i.e., K and Ca) and six trace elements (i.e., Mn, Fe, Cu, Zn, Se and Rb) in the aging process. The elements were determined by PIXE in cerebral cortex and white matter, basal ganglia, brainstem and cerebellar cortex of 18 postmortem human brains, from persons without a history of neurologic or psychiatric disease who deceased between the age of 7 and 79. This age range allowed us to study the relationship between elemental concentrations and age. The most prominent findings were a concentration decrease for K and Rb and a concentration increase for the elements Ca, Fe, Zn and Se. The study supports recent findings that Ca and Fe are involved in brain degenerative processes initiated by oxygen free radicals, whereas Zn and Se are involved in immunological reactions counteracting the aging process

  2. Trace elements in human milk

    Energy Technology Data Exchange (ETDEWEB)

    Parr, R M [International Atomic Energy Agency, Vienna (Austria). Div. of Life Sciences

    1983-06-01

    Trace elements are those elements having a concentration lower than 10 ppm in body fluids or tissues. A total of 24 elements, both trace and minor elements, present in human milk have been analysed in this study, employing neutron activation analysis and absorption spectroscopy. The analyses have been carried out collaboratively by several different laboratories and the Agency which has also served as a coordinating centre. Although the evaluation of the results, altogether 8500 separate values, is still in progress, enough evidence is already available, however, to show some very interesting differences between different study areas and, in some cases, between different socio-economic groups within a single country. The main value of these data will probably be to throw new light on the nutritional requirements of young babies for trace elements.

  3. Interactions of trace metals with hydrogels and filter membranes used in DET and DGT techniques.

    Science.gov (United States)

    Garmo, Oyvind A; Davison, William; Zhang, Hao

    2008-08-01

    Equilibrium partitioning of trace metals between bulk solution and hydrogels/filter was studied. Under some conditions, trace metal concentrations were higher in the hydrogels or filter membranes compared to bulk solution (enrichment). In synthetic soft water, enrichment of cationic trace metals in polyacrylamide hydrogels decreased with increasing trace metal concentration. Enrichment was little affected by Ca and Mg in the concentration range typically encountered in natural freshwaters, indicating high affinity but low capacity binding of trace metals to solid structure in polyacrylamide gels. The apparent binding strength decreased in the sequence: Cu > Pb > Ni approximately to Cd approximately to Co and a low concentration of cationic Cu eliminated enrichment of weakly binding trace metal cations. The polyacrylamide gels also had an affinity for fulvic acid and/or its trace metal complexes. Enrichment of cationic Cd in agarose gel and hydrophilic polyethersulfone filter was independent of concentration (10 nM to 5 microM) but decreased with increasing Ca/ Mg concentration and ionic strength, suggesting that it is mainly due to electrostatic interactions. However, Cu and Pb were enriched even after equilibration in seawater, indicating that these metals additionally bind to sites within the agarose gel and filter. Compared to the polyacrylamide gels, agarose gel had a lower affinity for metal-fulvic complexes. Potential biases in measurements made with the diffusive equilibration in thin-films (DET) technique, identified by this work, are discussed.

  4. A sensitive flow-batch system for on board determination of ultra-trace ammonium in seawater: Method development and shipboard application.

    Science.gov (United States)

    Zhu, Yong; Yuan, Dongxing; Huang, Yongming; Ma, Jian; Feng, Sichao

    2013-09-10

    Combining fluorescence detection with flow analysis and solid phase extraction (SPE), a highly sensitive and automatic flow system for measurement of ultra-trace ammonium in open ocean water was established. Determination was based on fluorescence detection of a typical product of o-phthaldialdehyde and ammonium. In this study, the fluorescence reaction product could be efficiently extracted onto an SPE cartridge (HLB, hydrophilic-lipophilic balance). The extracted fluorescence compounds were rapidly eluted with ethanol and directed into a flow cell for fluorescence detection. Compared with the common used fluorescence method, the proposed one offered the benefits of improved sensitivity, reduced reagent consumption, negligible salinity effect and lower cost. Experimental parameters were optimized using a univariate experimental design. Calibration curves, ranging from 1.67 to 300nM, were obtained with different reaction times. The recoveries were between 89.5 and 96.5%, and the detection limits in land-based and shipboard laboratories were 0.7 and 1.2nM, respectively. The relative standard deviation was 3.5% (n=5) for an aged seawater sample spiked with 20nM ammonium. Compared with the analytical results obtained using the indophenol blue method coupled to a long-path liquid waveguide capillary cell, the proposed method showed good agreement. The method had been applied on board during a South China Sea cruise in August 2012. A vertical profile of ammonium in the South East Asia Time-Series (SEATS, 18° N, 116° E) station was produced. The distribution of ammonium in the surface seawater of the Qiongdong upwelling in South China Sea is also presented. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Enhancing ultra-high CPV passive cooling using least-material finned heat sinks

    Energy Technology Data Exchange (ETDEWEB)

    Micheli, Leonardo, E-mail: lm409@exeter.ac.uk; Mallick, Tapas K., E-mail: T.K.Mallick@exeter.ac.uk [Environment and Sustainability Institute, University of Exeter, Penryn, Cornwall TR10 9FE (United Kingdom); Fernandez, Eduardo F., E-mail: E.Fernandez-Fernandez2@exeter.ac.uk [Environment and Sustainability Institute, University of Exeter, Penryn, Cornwall TR10 9FE (United Kingdom); Centre of Advanced Studies in Energy and Environment, University of Jaen, Jaen 23071 (Spain); Almonacid, Florencia, E-mail: facruz@ujaen.es [Centre of Advanced Studies in Energy and Environment, University of Jaen, Jaen 23071 (Spain); Reddy, K. S., E-mail: ksreddy@iitm.ac.in [Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, 600036 (India)

    2015-09-28

    Ultra-high concentrating photovoltaic (CPV) systems aim to increase the cost-competiveness of CPV by increasing the concentrations over 2000 suns. In this work, the design of a heat sink for ultra-high concentrating photovoltaic (CPV) applications is presented. For the first time, the least-material approach, widely used in electronics to maximize the thermal dissipation while minimizing the weight of the heat sink, has been applied in CPV. This method has the potential to further decrease the cost of this technology and to keep the multijunction cell within the operative temperature range. The designing procedure is described in the paper and the results of a thermal simulation are shown to prove the reliability of the solution. A prediction of the costs is also reported: a cost of 0.151$/W{sub p} is expected for a passive least-material heat sink developed for 4000x applications.

  6. Trace element analysis by EPMA in geosciences: detection limit, precision and accuracy

    Science.gov (United States)

    Batanova, V. G.; Sobolev, A. V.; Magnin, V.

    2018-01-01

    Use of the electron probe microanalyser (EPMA) for trace element analysis has increased over the last decade, mainly because of improved stability of spectrometers and the electron column when operated at high probe current; development of new large-area crystal monochromators and ultra-high count rate spectrometers; full integration of energy-dispersive / wavelength-dispersive X-ray spectrometry (EDS/WDS) signals; and the development of powerful software packages. For phases that are stable under a dense electron beam, the detection limit and precision can be decreased to the ppm level by using high acceleration voltage and beam current combined with long counting time. Data on 10 elements (Na, Al, P, Ca, Ti, Cr, Mn, Co, Ni, Zn) in olivine obtained on a JEOL JXA-8230 microprobe with tungsten filament show that the detection limit decreases proportionally to the square root of counting time and probe current. For all elements equal or heavier than phosphorus (Z = 15), the detection limit decreases with increasing accelerating voltage. The analytical precision for minor and trace elements analysed in olivine at 25 kV accelerating voltage and 900 nA beam current is 4 - 18 ppm (2 standard deviations of repeated measurements of the olivine reference sample) and is similar to the detection limit of corresponding elements. To analyse trace elements accurately requires careful estimation of background, and consideration of sample damage under the beam and secondary fluorescence from phase boundaries. The development and use of matrix reference samples with well-characterised trace elements of interest is important for monitoring and improving of the accuracy. An evaluation of the accuracy of trace element analyses in olivine has been made by comparing EPMA data for new reference samples with data obtained by different in-situ and bulk analytical methods in six different laboratories worldwide. For all elements, the measured concentrations in the olivine reference sample

  7. Determination of trace element concentrations and stable lead, uranium and thorium isotope ratios by quadrupole-ICP-MS in NORM and NORM-polluted sample leachates

    Energy Technology Data Exchange (ETDEWEB)

    Mas, J.L., E-mail: ppmasb@us.es [Dpto. Fisica Aplicada I, EPS, Universidad de Sevilla, 41012 Sevilla (Spain); Villa, M. [Servicio de Radioisotopos, Centro de Investigacion, Tecnologia e Innovacion (CITIUS), Universidad de Sevilla, Avda. Reina Mercedes 4b, 41012 Sevilla (Spain); Dpto. Fisica Aplicada II, ETS de Arquitectura, Universidad de Sevilla, Avda. Reina Mercedes 2, 41012 Sevilla (Spain); Hurtado, S. [Servicio de Radioisotopos, Centro de Investigacion, Tecnologia e Innovacion (CITIUS), Universidad de Sevilla, Avda. Reina Mercedes 4b, 41012 Sevilla (Spain); Garcia-Tenorio, R. [Dpto. Fisica Aplicada II, ETS de Arquitectura, Universidad de Sevilla, Avda. Reina Mercedes 2, 41012 Sevilla (Spain)

    2012-02-29

    Highlights: Black-Right-Pointing-Pointer Polluted sediment and NORM samples. Black-Right-Pointing-Pointer An efficient yet fast process allowing multi-parametric determinations in <3 days. Black-Right-Pointing-Pointer Trace element concentrations, Pb, Th and U isotope ratios with a single instrument. - Abstract: This work focuses on the monitoring of the potential pollution in scenarios that involve NORM-related industrial activities (environmental or in-door scenarios). The objective was to develop a method to determine extent and origin of the contamination, suitable for monitoring (i.e. simple, fast and economical) and avoiding the use of too many different instruments. It is presented a radiochemical method that allows the determination of trace element concentrations and {sup 206}Pb/{sup 207}Pb/{sup 208}Pb, {sup 238}U/{sup 234}U and {sup 232}Th/{sup 230}Th isotope ratios using a single sample aliquot and a single instrument (ICP-QMS). Eichrom UTEVA{sup Registered-Sign} extraction chromatography minicolumns were used to separate uranium and thorium in sample leachates. Independent ICP-MS determinations of uranium and thorium isotope ratios were carried out afterwards. Previously a small aliquot of the leachate was used for the determination of trace element concentrations and lead isotope ratios. Several radiochemical arrangements were tested to get maximum performances and simplicity of the method. The performances of the method were studied in terms of chemical yields of uranium and thorium and removal of the potentially interfering elements. The established method was applied to samples from a chemical industry and sediments collected in a NORM-polluted scenario. The results obtained from our method allowed us to infer not only the extent, but also the sources of the contamination in the area.

  8. Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration

    International Nuclear Information System (INIS)

    Yanliang Tan; Detao Xiao

    2013-01-01

    The paper will present a method based on the accumulation chamber technique for measuring of radon exhalation from the medium surface. A radon monitor traces the change of radon concentration in the accumulation chamber, and then the radon exhalation can be obtained accurately through linear fit. Based on our recent experiments, the radon exhalation rate from the medium surface obtained from this method is in good agreement with the actual exhalation rate of our simulation facility. This method is superior to the competition method which obtains the radon exhalation through the exponential fit by an external PC-system. The calculation for the exponential fit is very easy by computer and related software. However, for portable instruments, the single chip microcomputer can't calculate the exponential fit rapidly. Thus, this method is usable for developing the new portable instrument to classify building materials, etc. (author)

  9. Cryptic trace-element alteration of Anorthosite, Stillwater complex, Montana

    Science.gov (United States)

    Czamanske, G.K.; Loferski, P.J.

    1996-01-01

    Evidence of cryptic alteration and correlations among K, Ba, and LREE concentrations indicate that a post-cumulus, low-density aqueous fluid phase significantly modified the trace-element contents of samples from Anorthosite zones I and II of the Stillwater Complex, Montana. Concentrations of Ba, Ca, Co, Cr, Cu, Fe, Hf, K, Li, Mg, Mn, Na, Ni, Sc, Sr, Th, Zn, and the rare-earth elements (REE) were measured in whole rocks and plagioclase separates from five traverses across the two main plagioclase cumulate (anorthosite) zones and the contiguous cumulates of the Stillwater Complex in an attempt to better understand the origin and solidification of the anorthosites. However, nearly the entire observed compositional range for many trace elements can be duplicated at a single locality by discriminating between samples rich in oikocrystic pyroxene and those which are composed almost entirely of plagioclase and show anhedral-granular texture. Plagioclase separates with high trace-element contents were obtained from the pyroxene-poor samples, for which maps of K concentration show plagioclase grains to contain numerous fractures hosting a fine-grained, K-rich phase, presumed to be sericite. Secondary processes in layered intrusions have the potential to cause cryptic disturbance, and the utmost care must be taken to ensure that samples provide information about primary processes. Although plagioclase from Anorthosite zones I and II shows significant compositional variation, there are no systematic changes in the major- or trace-element compositions of plagioclase over as much as 630 m of anorthosite thickness or 18 km of strike length. Plagioclase in the two major anorthosite zones shows little distinction in trace-element concentrations from plagioclase in the cumulates immediately below, between, and above these zones.

  10. Transport of trace metals in the Magela Creek system, Northern Territory. I. Concentrations and loads of iron, manganese, cadmium, copper, lead and zinc during flood periods in the 1978-1979 wet season

    International Nuclear Information System (INIS)

    Hart, B.T.; Davies, S.H.R.; Thomas, P.A.

    1981-12-01

    In order that realistic effluent standards may be established for the Ranger uranium operations at Jabiru, Northern Territory, it is necessary that there be a clear and detailed knowledge of the pre-mining levels of trace metals and their behaviour within the Magela Creek system. During the wet season, floodwaters were sampled for conductivity, suspended solids and the trace metals, iron, manganese, cadmium, copper, lead and zinc. All concentrations were found to be very low, as were the denudation rates for the trace metals and suspended materials

  11. The mysterious trace amines: protean neuromodulators of synaptic transmission in mammalian brain.

    Science.gov (United States)

    Burchett, Scott A; Hicks, T Philip

    2006-08-01

    The trace amines are a structurally related group of amines and their isomers synthesized in mammalian brain and peripheral nervous tissues. They are closely associated metabolically with the dopamine, noradrenaline and serotonin neurotransmitter systems in mammalian brain. Like dopamine, noradrenaline and serotonin the trace amines have been implicated in a vast array of human disorders of affect and cognition. The trace amines are unique as they are present in trace concentrations, exhibit high rates of metabolism and are distributed heterogeneously in mammalian brain. While some are synthesized in their parent amine neurotransmitter systems, there is also evidence to suggest other trace amines may comprise their own independent neurotransmitter systems. A substantial body of evidence suggests that the trace amines may play very significant roles in the coordination of biogenic amine-based synaptic physiology. At high concentrations, they have well-characterized presynaptic "amphetamine-like" effects on catecholamine and indolamine release, reuptake and biosynthesis; at lower concentrations, they possess postsynaptic modulatory effects that potentiate the activity of other neurotransmitters, particularly dopamine and serotonin. The trace amines also possess electrophysiological effects that are in opposition to these neurotransmitters, indicating to some researchers the existence of receptors specific for the trace amines. While binding sites or receptors for a few of the trace amines have been advanced, the absence of cloned receptor protein has impeded significant development of their detailed mechanistic roles in the coordination of catecholamine and indolamine synaptic physiology. The recent discovery and characterization of a family of mammalian G protein-coupled receptors responsive to trace amines such as beta-phenylethylamine, tyramine, and octopamine, including socially ingested psychotropic drugs such as amphetamine, 3,4-methylenedioxymethamphetamine, N

  12. Vitrification by Ultra-fast Cooling at a Low Concentration of Cryoprotectants in a Quartz Microcapillary: A Study Using Murine Embryonic Stem Cells

    Science.gov (United States)

    He, Xiaoming; Park, Eric Y.H.; Fowler, Alex; Yarmush, Martin L.; Toner, Mehmet

    2009-01-01

    Conventional cryopreservation protocols for slow-freezing or vitrification involve cell injury due to ice formation/cell dehydration or toxicity of high cryoprotectant (CPA) concentrations, respectively. In this study, we developed a novel cryopreservation technique to achieve ultra-fast cooling rates using a quartz microcapillary (QMC). The QMC enabled vitrification of murine embryonic stem (ES) cells using an intracellular cryoprotectant concentration in the range used for slowing freezing (1–2 M). The cryoprotectants used included 2 M 1,2-propanediol (PROH, cell membrane permeable) and 0.5 M extracellular trehalose (cell membrane impermeable). More than 70% of the murine ES cells post-vitrification attached with respect to non-frozen control cells, and the proliferation rates of the two groups were similar. Preservation of undifferentiated properties of the pluripotent murine ES cells post vitrification cryopreservation was verified using three different types of assays: the expression of transcription factor Oct-4, the presentation of the membrane surface glycoprotein SSEA-1, and the elevated expression of the intracellular enzyme alkaline phosphatase. These results indicate that vitrification at a low concentration (2 M) of intracellular cryoprotectants is a viable and effective approach for the cryopreservation of murine embryonic stem cells. PMID:18462712

  13. Trace-element concentrations and water-soluble ions in size-segregated dust-borne and soil samples in Sistan, southeast Iran

    Science.gov (United States)

    Behrooz, Reza Dahmardeh; Esmaili-Sari, Abbas; Bahramifar, Nader; Kaskaoutis, D. G.; Saeb, Keivan; Rajaei, Fatemeh

    2017-04-01

    This study analyzes the chemical composition (water-soluble ions and trace elements) of the total suspended particles (TSP) and particulate matter less than 10 and 2.5 μm (PM10 and PM2.5) in the Sistan basin, southeast Iran during the dusty and windy period June - October 2014. Extreme TSP, PM10 and PM2.5 concentrations, means of 1624.8, 433.4 and 320.8 μgm-3, respectively, were recorded in the Zabol sampling site, while the examined water-soluble ions and trace metals constitute small fractions (∼4.1%-17.7%) of the particulate masses. Intense winds on the dust-storm days result in weathering of soil crust and deflation of evaporate minerals from the dried Hamoun lake beds in the Sistan basin. The soil samples are rich in Ca2+, SO42-, Na+ and Cl- revealing the existence of non-sea salts, as well as in Al, Fe and Mg, while the similarity in the chemical composition between soil and airborne samples indicates that the dust events over Sistan are local in origin. In contrast, low concentrations of secondary ions (i.e., nitrate) and heavy metals (i.e., Pb, Cr, Ni, Cu) indicate less anthropogenic and industrial emissions. Enrichment Factor analysis for TSP, PM10 and PM2.5 reveals that the anthropogenic sources contribute a substantial amount in the heavy metals rather than soil crust, while Al, Fe, Sn, Mg are mostly of crustal origin. The results provide essential knowledge in atmospheric chemistry over Sistan and in establishing mitigation strategies for air pollution control.

  14. PIXE analysis for bioaccumulation studies of trace elements

    International Nuclear Information System (INIS)

    Iwata, Y.; Satoh, A.; Sasaki, Y.; Ito, R.; Kuramachi, K.

    2005-01-01

    Bioaccumulation by micro-alga in the ocean was simulated in nutritive seawater containing known amounts of trace metals, and the concentration factors for Fe, Zn and Cd were measured by PIXE. Trace transition metals in nearshore seawater were removed by Chelex-100. Then a culture solution was prepared by adding known amounts of trace metals and nutritive salts to the purified seawater. Marine micro-algae (Nannochloropsis sp., and Phaeodactylum sp.,) were purely cultured in the culture solution. An interested metal ion was added to the culture solution (0.01-5.0 mg/l). Alga in 10 ml of the culture solution was collected on a polycarbonate filter (pore size: 1.0 ) by suction filtration and subjected to 2.9 MeV proton bombardment. Na, Mg, Al, Si, P, S, Cl, K, Ca, Cr, Mn, Fe, Zn and Cd were simultaneously determined. PIXE multi-element analysis was possible using less than 1 mg of analytical sample. The quantity of the metal in the alga was increased in proportion to the concentration in the culture solution. The concentration factors for Zn, Fe and Cd were measured, e.g., 10200 ± 300 ml/g to Zn for Phaeodactylum. The trend of the affinity for the trace metals in the case of Nannochloropsis was Fe 3+ > Zn 2+ > Pb 2+ > Cd 2+ . (author)

  15. The importance of biological factors affecting trace metal concentration as revealed from accumulation patterns in co-occurring terrestrial invertebrates

    Energy Technology Data Exchange (ETDEWEB)

    Hendrickx, Frederik; Maelfait, Jean-Pierre; Bogaert, Nicolas; Tojal, Catarina; Du Laing, Gijs; Tack, Filip M.G.; Verloo, Marc G

    2004-02-01

    As physicochemical properties of the soil highly influence the bioavailable fraction of a particular trace metal, measured metal body burdens in a particular species are often assumed to be more reliable estimators of the contamination of the biota. To test this we compared the Cd, Cu and Zn content of three spiders (generalist predators) and two amphipods (detritivores), co-occurring in seven tidal marshes along the river Schelde, between each other and with the total metal concentrations and the concentrations of four sequential extractions of the soils. Correlations were significant in only one case and significant sitexspecies interactions for all metals demonstrate that factors affecting metal concentration were species and site specific and not solely determined by site specific characteristics. These results emphasize that site and species specific biological factors might be of the utmost importance in determining the contamination of the biota, at least for higher trophic levels. A hypothetical example clarifies these findings. - Site and species specific biological factors are important in determining contamination of biota.

  16. Accurate depth profiling for ultra-shallow implants using backside-SIMS

    International Nuclear Information System (INIS)

    Hongo, Chie; Tomita, Mitsuhiro; Takenaka, Miyuki

    2004-01-01

    We studied methods for accurate depth profiling for ultra-shallow implants using backside-SIMS. For the measurement of ultra-shallow profiles, the effects of surface transient and atomic mixing are not negligible. Therefore, we applied backside-SIMS to analyze ultra-shallow doping in order to exclude these effects. Backside-SIMS profiles show a sharper ion implantation tail than surface-side-SIMS profiles. In addition, the primary ion energy dependence becomes weaker when backside-SIMS is used [Surf. Interf. Anal. 29 (2000) 362; Appl. Surf. Sci. 203-204 (2003) 264; J. Vac. Sci. Technol. B 21 (2003) 1422]. However, the peak concentration of the backside sample was lower than that of the surface-side sample. Therefore, the sample flatness was estimated using the SIMS response function. Furthermore, SIMS profiles were simulated using SIMS response functions. This simulation shows how the sample flatness affects the SIMS profile

  17. Trace element characterisation and purification of quartz powder of Indian origin

    International Nuclear Information System (INIS)

    Dash, K.; Thangavel, S.; Dhavile, S.M.; Sahayam, A.C.; Chaurasia, S.C.

    2002-11-01

    Analytical methodologies for the trace element characterisation and purification of quartz powder of Indian origin have been described. Metallic impurities (11 elements) in ∼700 quartz samples have been analysed using different instrumental techniques. The values are cross-validated by American and British analytical laboratories. A special multi channel vapour phase digestion (MCVPD) chamber has been designed to reduce the process blank levels for the determination of ultra trace impurities in high purity silicon matrix. In this vessel 21 samples can be digested at a time in a period of 8 hrs. at normal pressure and low temperature (∼ 80 degC). Analytical methodologies for the determination of non-metals (phosphorus, boron and chloride) at very low levels <1 ppm) have also been described. A highly cost effective, single step, room temperature purification procedure is developed based on chemical leaching. Around 300 raw quartz powders (3-4N) from various mines have been purified to 5N pure ( optical grade ). (author)

  18. Spatial Distribution of Trace Elements in Rice Field at Prafi District Manokwari

    Directory of Open Access Journals (Sweden)

    Aplena Elen S. Bless

    2016-08-01

    Full Text Available Mapping spatial variability of trace elements in rice Ḁeld is necessary to obtain soil quality information to en-hance rice production. ἀis study was aimed to measure concentration and distribution of Zn, Cu, Fe, Pb, and Cd in two diᴀerent sites (SP1, SP2 of PraḀ rice Ḁeld in Manokwari West Papua. ἀe representative 26 soil samples were analysed for their available trace metal concentration (DTPA, soil pH, and C-organic and soil texture. ἀe result indicated that Fe toxicity and Zn deḀcient problems were encountered in both sites.  Rice Ḁeld in SP2 was more deḀcient in Zn than SP1. Site with the highest trace elements (Zn, Fe, Cu, and Cd concentration had low soil pH and high C-organic. Acidic soil has higher solubility of metals; while high C-organic could improve the formation of dissolve organic carbon-metal binding, hence it improving the trace metals concentration in soil solution.

  19. Trace element analysis in rheumatoid arthritis under chrysotherapy

    International Nuclear Information System (INIS)

    Lecomte, R.; Paradis, P.; Monaro, S.; Barrette, M.; Lamoureux, G.; Menard, H.A.

    1981-01-01

    Proton induced X-ray emission (PIXE) analysis is used to measure trace element concentrations in blood serum from patients with rheumatoid arthritis. Initially trace element contaminations in blood-collecting and storing devices are determined. Then mean values and nyctemeral cycles are measured both in normal subjects and patients with rheumatoid arthritis and other similar pathologies. Abnormal concentrations of Cu and Zn and anomalies in the nyctemeral cycle are found in the patients. In the second phase of the project, the special case of chrysotherapeutically treated (gold salt treatment) rheumatoid arthritis patients is studied for extended periods of time (up to 53 weeks). (orig.)

  20. Trace analysis of actinides in the environment using resonance ionization mass spectrometry; Spurenanalyse von Aktiniden in der Umwelt mittels Resonanzionisations-Massenspektrometrie

    Energy Technology Data Exchange (ETDEWEB)

    Raeder, Sebastian

    2011-04-12

    In this work the resonant ionization of neutral atoms using laser radiation was applied and optimized for ultra-trace analysis of the actinides thorium, uranium, neptunium and plutonium. The sensitive detection of these actinides is a challange for the monitoring and quantification of radioactive releases from nuclear facilities. Using resonance ionization spectroscopy combined with a newly developed quadrupole-mass-spectrometer, numerous energy levels in the atomic structure of these actinides could be identified. With this knowledge efficient excitation schemes for the mentioned actinides could be identified and characterised. The applied in-source-ionization ensures for a high detection efficiency due to the good overlap of laser radiation with the atomic beam and allows therefore for a low sample consumption which is required for the analysis of radio nuclides. The selective excitation processes in the resonant ionization method supresses unwanted contaminations and was optimized for analytical detection of ultra-trace amounts in environmental samples as well as for determination of isotopic compositions. The efficient in-source-ionization combined with high power pulsed laser radiation allows for detections efficiency up to 1%. For plutonium detection limits in the range of 10{sup 4}-10{sup 5} atoms could be demonstrated for synthetic samples as well as for first environmental samples. The usage of narrow bandwidth continuous wave lasers in combination with a transversal overlap of the laser radiation and the free propagating atomic beam enable for resolving individual isotopic shifts of the resonant transitions. This results in a high selectivity against dominant neighboring isotopes but with a significant loss in detection efficiency. For the ultra-trace isotope {sup 236}U a detection limit down to 10{sup -9} for the isotope ratio N ({sup 236}U)/N ({sup 238}U) could be determined.

  1. Concentrations of trace elements and PCDD/Fs around a municipal solid waste incinerator in Girona (Catalonia, Spain). Human health risks for the population living in the neighborhood.

    Science.gov (United States)

    Rovira, Joaquim; Nadal, Martí; Schuhmacher, Marta; Domingo, José L

    2018-07-15

    Previously to the modernization of the municipal solid waste incinerator (MSWI) of Campdorà (Girona, Catalonia, Spain) two sampling campaigns (2015 and 2016) were conducted. In each campaign, 8 soil and 4 air samples (PM 10 and total particle phase and gas phase) were collected. The levels of As, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Sn, Tl and V, and PCDD/Fs were analysed at different distances and wind directions around the MSWI. Environmental levels of trace elements and PCDD/Fs were used to assess exposure and health risks (carcinogenic and non-carcinogenic) for the population living around the facility. In soils, no significant differences were observed for trace elements and PCDD/Fs between both campaigns. In air, significant higher levels of As, Cd, Co, Mn, Ni, Pb, Tl and V were detected in 2016. Regarding soil levels, only Cd (distances) and As, Cu, Mn, and Ni (wind directions) showed significant differences. No differences were noted in the concentrations of trace elements and PCDD/Fs in air levels with respect to distances and directions to the MSWI. No differences were registered in air levels (elements and PCDD/Fs) between points influenced by MSWI emissions and background point. However some differences in congener profile were noted regarding from where back-trajectories come from (HYSPLIT model results), pointing some influence of Barcelona metropolitan area. The concentrations of trace elements and PCDD/Fs were similar -or even lower- than those reported around other MSWIs in Catalonia and various countries. Non-carcinogenic risks were below the safety limit (HQ<1). In turn, carcinogenic risks due to exposure to trace elements and PCDD/Fs were in acceptable ranges, according to national and international standard regulations. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Macro-Elements and Trace Elements in Cereal Grains Cultivated in Latvia

    Directory of Open Access Journals (Sweden)

    Jākobsone Ida

    2015-09-01

    Full Text Available Cereal-based foods have great importance in the compensation of micro- and trace element deficiency, because 50% of the foods produced worldwide are made up of cereal grains. The aim of the research was to determine the concentration of macro-elements and trace elements in different cereals cultivated in Latvia. Various cereals were used in the research: rye (n = 45, barley (n = 54, spring wheat (n = 27, winter wheat (n = 53, triticale (n = 45 and oats (n = 42. Thirteen macro- and trace elements (Cd, Pb, Ni, Cr, Al, Cu, K, Na, Mn, Fe, Zn, Mg, Ca were determined in cereal grain samples (n = 266. Macro-elements and trace elements varied significantly (p < 0.01 or p < 0.001. The highest concentrations of macro- and trace elements were found in oats and the lowest in rye. The obtained data will expand the opportunity for food and nutrition scientists to evaluate content of the examined elements in grain products, and dietary consumption (bioavailability of the examined macro-elements and trace elements.

  3. Water and sodium intake habits and status of ultra-endurance runners during a multi-stage ultra-marathon conducted in a hot ambient environment: an observational field based study

    Directory of Open Access Journals (Sweden)

    Costa Ricardo JS

    2013-01-01

    Full Text Available Abstract Background Anecdotal evidence suggests ultra-runners may not be consuming sufficient water through foods and fluids to maintenance euhydration, and present sub-optimal sodium intakes, throughout multi-stage ultra-marathon (MSUM competitions in the heat. Subsequently, the aims were primarily to assess water and sodium intake habits of recreational ultra-runners during a five stage 225 km semi self-sufficient MSUM conducted in a hot ambient environment (Tmax range: 32°C to 40°C; simultaneously to monitor serum sodium concentration, and hydration status using multiple hydration assessment techniques. Methods Total daily, pre-stage, during running, and post-stage water and sodium ingestion of ultra-endurance runners (UER, n = 74 and control (CON, n = 12 through foods and fluids were recorded on Stages 1 to 4 by trained dietetic researchers using dietary recall interview technique, and analysed through dietary analysis software. Body mass (BM, hydration status, and serum sodium concentration were determined pre- and post-Stages 1 to 5. Results Water (overall mean (SD: total daily 7.7 (1.5 L/day, during running 732 (183 ml/h and sodium (total daily 3.9 (1.3 g/day, during running 270 (151 mg/L ingestion did not differ between stages in UER (p vs. CON. Exercise-induced BM loss was 2.4 (1.2% (p p > 0.05 vs. CON pre-stage. Asymptomatic hyponatraemia (n = 8 UER, corresponding to 42% of sampled participants. Pre- and post-stage urine colour, urine osmolality and urine/plasma osmolality ratio increased (p p  Conclusion Water intake habits of ultra-runners during MSUM conducted in hot ambient conditions appear to be sufficient to maintain baseline euhydration levels. However, fluid over-consumption behaviours were evident along competition, irrespective of running speed and gender. Normonatraemia was observed in the majority of ultra-runners throughout MSUM, despite sodium ingestion under benchmark recommendations.

  4. Effects of Cigarette Smoke on Tissue Trace Element Concentration of Rats Exposed to Second-hand Smoke

    OpenAIRE

    K, Ergen; F, Yildiz; M, Ozcan; M, Cekmen; , Tanyeri P; , Utkan T; Y, Karakoc

    2012-01-01

    Trace elements have an important effect on and play a key role in a variety of the processes necessary for life. Studies have indicated a definite correlation between content of trace elements and many common diseases. It has been concluded that smoking may be a substantial source of intake of these hazardous elements, not only to the smoker, but to nonsmokers via passive smoke, as well. Even passive intake of such elements can change the metabolism of other trace elements and influence their...

  5. SolTrace: A Ray-Tracing Code for Complex Solar Optical Systems

    Energy Technology Data Exchange (ETDEWEB)

    Wendelin, Tim [National Renewable Energy Lab. (NREL), Golden, CO (United States); Dobos, Aron [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lewandowski, Allan [Allan Lewandowski Solar Consulting LLC, Evergreen, CO (United States)

    2013-10-01

    SolTrace is an optical simulation tool designed to model optical systems used in concentrating solar power (CSP) applications. The code was first written in early 2003, but has seen significant modifications and changes since its inception, including conversion from a Pascal-based software development platform to C++. SolTrace is unique in that it can model virtually any optical system utilizingthe sun as the source. It has been made available for free and as such is in use worldwide by industry, universities, and research laboratories. The fundamental design of the code is discussed, including enhancements and improvements over the earlier version. Comparisons are made with other optical modeling tools, both non-commercial and commercial in nature. Finally, modeled results are shownfor some typical CSP systems and, in one case, compared to measured optical data.

  6. Relationship between trace element content in human organs and hair

    International Nuclear Information System (INIS)

    Kinova, L.

    1993-01-01

    Autopsy samples from 22 clinically healthy human males between the ages of 20 to 52 were collected from Bulgaria for the investigation of possible correlations between trace elements in hair and body organs. Samples of heart, spleen, liver, kidney, and hair were analyzed by neutron activation analysis to determine trace element concentrations. Statistical analysis of the data did not indicate any significant correlations between elemental concentrations in hair and internal organs, probably due to the limited number of available samples. However, lower than normal selenium concentrations were found in the organ samples, indicating possible selenium deficiency. (author). 6 refs, 4 tabs

  7. Epidemic contact tracing via communication traces.

    Directory of Open Access Journals (Sweden)

    Katayoun Farrahi

    Full Text Available Traditional contact tracing relies on knowledge of the interpersonal network of physical interactions, where contagious outbreaks propagate. However, due to privacy constraints and noisy data assimilation, this network is generally difficult to reconstruct accurately. Communication traces obtained by mobile phones are known to be good proxies for the physical interaction network, and they may provide a valuable tool for contact tracing. Motivated by this assumption, we propose a model for contact tracing, where an infection is spreading in the physical interpersonal network, which can never be fully recovered; and contact tracing is occurring in a communication network which acts as a proxy for the first. We apply this dual model to a dataset covering 72 students over a 9 month period, for which both the physical interactions as well as the mobile communication traces are known. Our results suggest that a wide range of contact tracing strategies may significantly reduce the final size of the epidemic, by mainly affecting its peak of incidence. However, we find that for low overlap between the face-to-face and communication interaction network, contact tracing is only efficient at the beginning of the outbreak, due to rapidly increasing costs as the epidemic evolves. Overall, contact tracing via mobile phone communication traces may be a viable option to arrest contagious outbreaks.

  8. Epidemic contact tracing via communication traces.

    Science.gov (United States)

    Farrahi, Katayoun; Emonet, Rémi; Cebrian, Manuel

    2014-01-01

    Traditional contact tracing relies on knowledge of the interpersonal network of physical interactions, where contagious outbreaks propagate. However, due to privacy constraints and noisy data assimilation, this network is generally difficult to reconstruct accurately. Communication traces obtained by mobile phones are known to be good proxies for the physical interaction network, and they may provide a valuable tool for contact tracing. Motivated by this assumption, we propose a model for contact tracing, where an infection is spreading in the physical interpersonal network, which can never be fully recovered; and contact tracing is occurring in a communication network which acts as a proxy for the first. We apply this dual model to a dataset covering 72 students over a 9 month period, for which both the physical interactions as well as the mobile communication traces are known. Our results suggest that a wide range of contact tracing strategies may significantly reduce the final size of the epidemic, by mainly affecting its peak of incidence. However, we find that for low overlap between the face-to-face and communication interaction network, contact tracing is only efficient at the beginning of the outbreak, due to rapidly increasing costs as the epidemic evolves. Overall, contact tracing via mobile phone communication traces may be a viable option to arrest contagious outbreaks.

  9. Concentrations of 137Cs and trace elements in zooplankton, and their vertical distributions off Rokkasho, Japan

    International Nuclear Information System (INIS)

    Kaeriyama, Hideki; Ishii, Toshiaki; Watabe, Teruhisa; Kusakabe, Masashi

    2007-01-01

    Zooplankton samples were collected at about 50 m depth with a large ring net (160-cm mouth diameter, 0.5-mm mesh) in May, June, October 2005 and June 2006 off Rokkasho, Japan where a nuclear fuel reprocessing plant will be in full-scale operation in the near future. Plankters in each sample were separated based on their species. Eight samples were used for the determination of 137 Cs concentration and the other 21 samples were used for the determination of its stable isotope, Cs along with some other trace elements. All the samples were characterized by five dominant species, i.e. euphausiids, chaetognaths, copepods; Neocalanus spp., amphipods; Themisto spp. and Cyphocaris sp. Plankton samples were also taken at three to five discrete depths between the surface and ≤ 1,000 m in depth during daytime and nighttime for analysis of vertical distribution patterns of biomass, and for assessment of daily vertical migration activity. Integrated net zooplankton biomass at nighttime ranged from 0.85 to 8.74 g-DW m -2 in the 0-150 m layer without any appreciable day-night differences in the vertical distribution; below the layer, it decreased significantly. Only in spring, appreciable day-night differences in the vertical distribution were observed at the shallowest station. Concentrations of Cs and Co did not show significant difference among the five species. However, higher concentrations of Sr were observed in two amphipods. It is likely that amphipods had a different biological process in Sr metabolism from others. The concentration of 137 Cs in zooplankton was usually very low and sometimes under the detection limit. In the present study, the highest concentration of 137 Cs in zooplankton was 24 mBq kg-WW -1 , corresponding to the concentration factor (CF) of 14, if the value of 1.7 mBq L -1 was given to the 137 Cs concentration in seawater. The water-column inventory of 137 Cs in a zooplankton community is calculated to be 0.29 to 1.95 mBq m -2 , based on the data on

  10. Uptake of trace elements in adult and suckling rat lenses

    International Nuclear Information System (INIS)

    Nabekura, Tomohiro; Ito, Yoshimasa; Minami, Takeshi; Hirunuma, Rieko; Enomoto, Shuichi

    2001-01-01

    The uptake of trace elements in the lens was compared in adult and suckling rat lenses. Multitracers, including 15 trace elements, As, Be, Co, Fe, Mn, Rb, Rh, Ru, Sc, Se, Sr, Y, V, Zn, and Zr, were incubated with the lenses for 4 hr and their concentrations in the lens were measured. A high uptake rate of Zn was observed in the lenses of both adult and suckling rats in comparison with those of the other elements, and the Zn concentration in the lens of suckling rats was higher than that of adult rats. The uptake rate of Sr was higher in adult rats than in suckling rats. On the other contrary, Rb and Se concentrations in the lens were higher in suckling rats than in adult rats. The present study suggests that the different mechanisms depending on development serve to transport trace elements into the lens. (author)

  11. Designable ultra-smooth ultra-thin solid-electrolyte interphases of three alkali metal anodes.

    Science.gov (United States)

    Gu, Yu; Wang, Wei-Wei; Li, Yi-Juan; Wu, Qi-Hui; Tang, Shuai; Yan, Jia-Wei; Zheng, Ming-Sen; Wu, De-Yin; Fan, Chun-Hai; Hu, Wei-Qiang; Chen, Zhao-Bin; Fang, Yuan; Zhang, Qing-Hong; Dong, Quan-Feng; Mao, Bing-Wei

    2018-04-09

    Dendrite growth of alkali metal anodes limited their lifetime for charge/discharge cycling. Here, we report near-perfect anodes of lithium, sodium, and potassium metals achieved by electrochemical polishing, which removes microscopic defects and creates ultra-smooth ultra-thin solid-electrolyte interphase layers at metal surfaces for providing a homogeneous environment. Precise characterizations by AFM force probing with corroborative in-depth XPS profile analysis reveal that the ultra-smooth ultra-thin solid-electrolyte interphase can be designed to have alternating inorganic-rich and organic-rich/mixed multi-layered structure, which offers mechanical property of coupled rigidity and elasticity. The polished metal anodes exhibit significantly enhanced cycling stability, specifically the lithium anodes can cycle for over 200 times at a real current density of 2 mA cm -2 with 100% depth of discharge. Our work illustrates that an ultra-smooth ultra-thin solid-electrolyte interphase may be robust enough to suppress dendrite growth and thus serve as an initial layer for further improved protection of alkali metal anodes.

  12. PIXE trace element analysis of a selection of wines

    International Nuclear Information System (INIS)

    Houdayer, A.; Hinrichsen, P.F.; Martin, J.P.; Belhadfa, A.

    1987-01-01

    The University of Montreal EN Tandem accelerator and a Si (Li) X-ray detector were used for a PIXE (Proton Induced X-ray emission) trace element analysis of a selection of wines. Quantitative measurements of the concentrations of the sixteen trace elements Na, Mg, Al, Si, P, S, Cl, K, Ca, Cr, Mn, Fe, Co, Cu, Zn, and Br were made. To optimize the sensitivity, spectra were recorded at 1.0 MeV proton energy for elements with Z 19. The absolute concentrations of the trace elements were determined by doping the samples of wine with 1000 ppm of vanadium for the 1.0 MeV bombardments, and 1000 ppm of yttrium for the 3.0 MeV irradiations. The targets were prepared by depositing a few microliters of the wine onto a Nuclepore filter

  13. Trace-element analysis in environmental sciences

    International Nuclear Information System (INIS)

    Valkovic, V.; Moschini, G.

    1988-01-01

    The use of charged-particle accelerators in trace-element analysis in the field of environmental sciences is described in this article. Nuclear reactions, charged-particle-induced X-ray emission as well as other nuclear and atomic processes can be used individually, or combined, in developing adequate analytical systems. In addition to concentration levels, concentration levels, concentration profiles can be measured, resulting in unique information. Some examples of experiments performed are described together with the suggestions for future measurements [pt

  14. Determination of trace elements in cigarette and tobacco by neutron activation analysis

    International Nuclear Information System (INIS)

    Nouchpramool, S.

    1988-01-01

    The objective of this work is to determine the concentration of 22 trace elements in cigarette and tobacco by instrumental neutron activation analysis in which multielements can be analyzed simultaneously with high sensitivity and reliability as well as easy and rapid. It is well known that, trace toxic elements with high concentration may be harmful for health of smokers. Since they might damage the respiratory system and might cause other diseases. The finding for this report can be used as the basis of further study on toxic of trace elements to the smoker. The results of this analysis show that the bromine content in all samples is significantly high, but the concentration of the other elements are varying from one to another. Bromine concentration might come from soil and/or smoked tobacco leaves with methyl bromide as fungicide

  15. Trace elements in Australian opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Fardy, J.J.

    1994-01-01

    Neutron activation analysis was used to determine the concentration of trace elements in 42 samples of black, grey and white opals taken from a number of recognised Australian field. The results were evaluated to determine if a relationship exited between trace element content and opal colour. (author) 12 refs.; 12 figs.; 3 tabs

  16. Trace element analysis of human blood serum by neutron activation analysis

    International Nuclear Information System (INIS)

    Nakahara, H.; Nagame, Y.; Yoshizawa, Y.; Oda, H.; Gotoh, S.; Murakami, Y.

    1979-01-01

    An attempt was made to determine if there is any correlation between trace element concentrations in human blood serum and some specific diseases. The serum samples of the patients suffering from cancer, Down syndrome, and Banti syndrome were analyzed by the neutron activation method and compared with the trace element concentrations observed among clinically healthy men. The cancer patients had concentrations in Rb, Mn, Fe, Co, Cu, Zn, Al and Se below normal. The Down syndrome patients were found to have similar deficiencies in Cr, Mn, Fe, Co, Zn, Cu and Sb. (author)

  17. Determination of trace concentrations of chlorine in aqueous solutions by high-resolution continuum source graphite furnace molecular absorption spectrometry

    Science.gov (United States)

    Machyňák, Ľubomír; Čacho, František; Němeček, Martin; Beinrohr, Ernest

    2016-11-01

    Trace concentrations of total chlorine were determined by means of molecular absorption of indium mono-chloride (InCl) at 267.217 nm using high-resolution continuum source graphite furnace molecular absorption spectrometry. The effects of chemical modifiers and the amount of In on the sensitivity and accuracy were investigated. The optimum pyrolysis and vaporization temperatures were 600 °C and 1400 °C, respectively. The limit of detection and characteristic mass were found to be 0.10 ng and 0.21 ng, respectively. Potential non-spectral and spectral interferences were tested for various metals and non-metals at concentrations up to 50 mg L- 1 and for phosphoric, sulphuric and nitric acids. No spectral interferences were observed. Significant non-spectral interferences were observed with F, Br, and I at concentrations higher than 1 mg L- 1, 5 mg L- 1 and 25 mg L- 1, respectively, which is probably caused by formation of competitive indium halogen molecules. Higher concentrations of mineral acids depressed the signal owing to the formation of volatile HCl. The calibration curve was linear in the range between 0.3 and 10 ng with a correlation coefficient of R = 0.993. The elaborated method was used for the chlorine determination in various waters and a drug sample.

  18. Trace elements in natural drugs determined by INAA

    International Nuclear Information System (INIS)

    Chen Kehshaw; Tseng Chialiang; Lin Tehsien

    1993-01-01

    Natural drugs are widely used for diuretic, phlegm elimination and stomach invigoration purposes. Seventy-five of the most common remedies used by Chinese people have been subjected to trace element survey analysis by instrumental neutron activation. Within this large number of different natural products, fourteen trace elements (K, Sc, Cr, Fe, Co, Zn, Br, Rb, Cs, La, Sm, Eu, Au and Th) are commonly detected. Among these elements, Fe had the highest concentration followed by Zn, and Rb, Sm, Eu and Au were found to have the lowest concentrations. Although the three groups of natural drugs exhibit a widely different therapeutic action, the concentration ranges of the fourteen elements were very similar. While this suggests no apparent specific role for the trace elements in the drug function, parallels are drawn between the known drug related functions of Rb, Zn, Br, Fe, Co and K and the levels of elements found in the natural drugs. It is concluded that the various natural drugs also provide human benefits through supplements of essential elements such as Fe, Zn, Cr, Sc, Rb and Co. (author) 13 refs.; 5 tabs

  19. Influence of Oxygen Concentration on the Performance of Ultra-Thin RF Magnetron Sputter Deposited Indium Tin Oxide Films as a Top Electrode for Photovoltaic Devices

    Directory of Open Access Journals (Sweden)

    Jephias Gwamuri

    2016-01-01

    Full Text Available The opportunity for substantial efficiency enhancements of thin film hydrogenated amorphous silicon (a-Si:H solar photovoltaic (PV cells using plasmonic absorbers requires ultra-thin transparent conducting oxide top electrodes with low resistivity and high transmittances in the visible range of the electromagnetic spectrum. Fabricating ultra-thin indium tin oxide (ITO films (sub-50 nm using conventional methods has presented a number of challenges; however, a novel method involving chemical shaving of thicker (greater than 80 nm RF sputter deposited high-quality ITO films has been demonstrated. This study investigates the effect of oxygen concentration on the etch rates of RF sputter deposited ITO films to provide a detailed understanding of the interaction of all critical experimental parameters to help create even thinner layers to allow for more finely tune plasmonic resonances. ITO films were deposited on silicon substrates with a 98-nm, thermally grown oxide using RF magnetron sputtering with oxygen concentrations of 0, 0.4 and 1.0 sccm and annealed at 300 °C air ambient. Then the films were etched using a combination of water and hydrochloric and nitric acids for 1, 3, 5 and 8 min at room temperature. In-between each etching process cycle, the films were characterized by X-ray diffraction, atomic force microscopy, Raman Spectroscopy, 4-point probe (electrical conductivity, and variable angle spectroscopic ellipsometry. All the films were polycrystalline in nature and highly oriented along the (222 reflection. Ultra-thin ITO films with record low resistivity values (as low as 5.83 × 10−4 Ω·cm were obtained and high optical transparency is exhibited in the 300–1000 nm wavelength region for all the ITO films. The etch rate, preferred crystal lattice growth plane, d-spacing and lattice distortion were also observed to be highly dependent on the nature of growth environment for RF sputter deposited ITO films. The structural, electrical

  20. Ultra-urban baseflow and stormflow concentrations and fluxes in a watershed undergoing restoration (WS263)

    Science.gov (United States)

    Kenneth T. Belt; William P. Stack; Richard V. Pouyat; Kimberly Burgess; Peter M. Groffman; William M. Frost; Sujay S. Kaushal; Guy. Hager

    2014-01-01

    We discuss the results of sampling baseflow and stormwater runoff in Watershed 263, an ultra-urban catchment in west Baltimore City that is undergoing restoration aimed at both improving water quality as well as the quality of life in its neighborhoods. We focus on urban hydrology and describe the high baseflow and stormwater nutrient, metal, bacterial and other...

  1. Gamma-ray spectrometry of ultra low levels of radioactivity within the material screening program for the GERDA experiment.

    Science.gov (United States)

    Budjás, D; Gangapshev, A M; Gasparro, J; Hampel, W; Heisel, M; Heusser, G; Hult, M; Klimenko, A A; Kuzminov, V V; Laubenstein, M; Maneschg, W; Simgen, H; Smolnikov, A A; Tomei, C; Vasiliev, S I

    2009-05-01

    In present and future experiments in the field of rare events physics a background index of 10(-3) counts/(keV kg a) or better in the region of interest is envisaged. A thorough material screening is mandatory in order to achieve this goal. The results of a systematic study of radioactive trace impurities in selected materials using ultra low-level gamma-ray spectrometry in the framework of the GERDA experiment are reported.

  2. Trace element analysis in soy sauce

    International Nuclear Information System (INIS)

    Haruyama, Yoichi; Saito, Manabu; Tomiya, Michio

    1993-01-01

    Trace elements in soy sauce have been measured by means of in-air PIXE. Six kinds of trace elements were detected, such as Mn, Fe, Ni, Zn, Cu and Br. Concentrations of Mn, Fe, Zn and Br which were observed in all samples, have been determined. Each analyzed sample contained considerable amount of Br about 160 ppm. Comparison of Br content of the imported raw materials with those of the domestic ones suggested that the large amount of Br was the residual fumigation chemicals in the imported raw materials. (author)

  3. Concentrations and solubility of selected trace metals in leaf and bagged black teas commercialized in Poland

    Directory of Open Access Journals (Sweden)

    L. Polechońska

    2015-09-01

    Full Text Available The objective of this study was to determine the concentrations of heavy metals in bagged and leaf black teas of the same brand and evaluate the percentage transfer of metals to tea infusion to assess the consumer exposure. Ten leaf black teas and 10 bagged black teas of the same brand available in Poland were analyzed for Zn, Mn, Cd, Pb, Ni, Co, Cr, Al, and Fe concentrations both in dry material and their infusion. The bagged teas contained higher amounts of Pb, Mn, Fe, Ni, Al, and Cr compared with leaf teas of the same brand, whereas the infusions of bagged tea contained higher levels of Mn, Ni, Al, and Cr compared with leaf tea infusions. Generally, the most abundant trace metals in both types of tea were Al and Mn. There was a wide variation in percentage transfer of elements from the dry tea materials to the infusions. The solubility of Ni and Mn was the highest, whereas Fe was insoluble and only a small portion of this metal content may leach into infusion. With respect to the acceptable daily intake of metals, the infusions of both bagged and leaf teas analyzed were found to be safe for human consumption.

  4. Report on intercomparison IAEA/W-4 of the determination of trace elements in simulated fresh water

    International Nuclear Information System (INIS)

    Pszonicki, L.; Hanna, A.N.; Suschny, O.

    1985-05-01

    The report presents results of a laboratory intercomparison on the determination of trace elements in simulated fresh water. 20 trace elements were analyzed by 38 laboratories from 21 countries. The results of the reported comparison confirm the agreement of the nominal concentration values of trace elements in the IAEA/W-4 simulated fresh water with the determined values of these elements. They also confirm that concentrated solutions of this type can be stored in quartz ampoules without any noticeable changes due to the adsorption of trace components on the quartz wall of vessels for considerable time. The concentration values of trace elements could be certified and the material IAEA/W-4 simulated fresh water issued as a reference material. 84% of all results were obtained either by atomic absorption or by atomic emission spectroscopy

  5. Towards CMOS-compatible nanophotonics: Ultra-compact modulators using alternative plasmonic materials

    DEFF Research Database (Denmark)

    Babicheva, Viktoriia; Kinsey, Nathaniel; Naik, Gururaj V.

    2013-01-01

    We propose several planar layouts of ultra-compact plasmonic modulators that utilize alternative plasmonic materials such as transparent conducting oxides and titanium nitride. The modulation is achieved by tuning the carrier concentration in a transparent conducting oxide layer into and out of t...

  6. Characterization of atmospheric trace elements in the Puruogangri ice core: a preliminary account of Tibetan Plateau environmental and contamination histories

    Science.gov (United States)

    Beaudon, E.; Gabrielli, P.; Sierra Hernandez, R.; Wegner, A.; Thompson, L. G.

    2014-12-01

    Asia is facing enormous challenges including large-scale environmental changes, rapid population growth and industrialization. The inherent generated pollution contributes to half of all Earth's anthropogenic trace metals emissions that, when deposited to glaciers of the surrounding mountains of the Third Pole region, leave a characteristic chemical fingerprint. Records of past atmospheric deposition preserved in snow and ice from Third Pole glaciers provide unique insights into changes of the chemical composition of the atmosphere and into the nature and intensity of the regional atmospheric circulation systems. The determination of the elemental composition of aeolian dust stored in Himalayan and Tibetan Plateau glaciers can help to qualify the potential contamination of glacial meltwater as a part of the greater fresh Asian water source. The 215 m long Puruogangri ice core retrieved in 2000 at 6500 m a.s.l. in central Tibetan Plateau (Western Tanggula Shan, China) provides one of the first multi-millennium-long environmental archives (spanning the last 7000 years and annually resolved for the last 400 years) obtained from the Tibetan Plateau region. The Puruogangri's area is climatologically of particular interest because of its location at the boundary between the monsoon (wet) and the westerly (dry) dominated atmospheric circulation. The major objective of this study is to determine the concentration of trace and ultra-trace elements in the Puruogangri ice core between 1600 and 2000 AD in order to characterize the atmospheric aerosols entrapped in the ice. Particular attention is given to assess the amount of trace elements originating from anthropogenic sources during both the pre-industrial and industrial periods. The distinction between the anthropogenic contribution and the crustal background may rely on the precise decoupling of the dry and wet seasons signals, the former being largely influenced by dust contribution.

  7. Mapping human health risks from exposure to trace metal contamination of drinking water sources in Pakistan

    International Nuclear Information System (INIS)

    Bhowmik, Avit Kumar; Alamdar, Ambreen; Katsoyiannis, Ioannis; Shen, Heqing; Ali, Nadeem; Ali, Syeda Maria; Bokhari, Habib; Schäfer, Ralf B.; Eqani, Syed Ali Musstjab Akber Shah

    2015-01-01

    The consumption of contaminated drinking water is one of the major causes of mortality and many severe diseases in developing countries. The principal drinking water sources in Pakistan, i.e. ground and surface water, are subject to geogenic and anthropogenic trace metal contamination. However, water quality monitoring activities have been limited to a few administrative areas and a nationwide human health risk assessment from trace metal exposure is lacking. Using geographically weighted regression (GWR) and eight relevant spatial predictors, we calculated nationwide human health risk maps by predicting the concentration of 10 trace metals in the drinking water sources of Pakistan and comparing them to guideline values. GWR incorporated local variations of trace metal concentrations into prediction models and hence mitigated effects of large distances between sampled districts due to data scarcity. Predicted concentrations mostly exhibited high accuracy and low uncertainty, and were in good agreement with observed concentrations. Concentrations for Central Pakistan were predicted with higher accuracy than for the North and South. A maximum 150–200 fold exceedance of guideline values was observed for predicted cadmium concentrations in ground water and arsenic concentrations in surface water. In more than 53% (4 and 100% for the lower and upper boundaries of 95% confidence interval (CI)) of the total area of Pakistan, the drinking water was predicted to be at risk of contamination from arsenic, chromium, iron, nickel and lead. The area with elevated risks is inhabited by more than 74 million (8 and 172 million for the lower and upper boundaries of 95% CI) people. Although these predictions require further validation by field monitoring, the results can inform disease mitigation and water resources management regarding potential hot spots. - Highlights: • Predictions of trace metal concentration use geographically weighted regression • Human health risk

  8. Mapping human health risks from exposure to trace metal contamination of drinking water sources in Pakistan

    Energy Technology Data Exchange (ETDEWEB)

    Bhowmik, Avit Kumar [Institute for Environmental Sciences, University of Koblenz-Landau, Fortstrasse 7, D-76829 Landau in der Pfalz (Germany); Alamdar, Ambreen [Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021 (China); Katsoyiannis, Ioannis [Aristotle University of Thessaloniki, Department of Chemistry, Division of Chemical Technology, Box 116, Thessaloniki 54124 (Greece); Shen, Heqing [Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021 (China); Ali, Nadeem [Department of Environmental Sciences, FBAS, International Islamic University, Islamabad (Pakistan); Ali, Syeda Maria [Center of Excellence in Environmental Studies, King Abdulaziz University, Jeddah (Saudi Arabia); Bokhari, Habib [Public Health and Environment Division, Department of Biosciences, COMSATS Institute of Information Technology, Islamabad (Pakistan); Schäfer, Ralf B. [Institute for Environmental Sciences, University of Koblenz-Landau, Fortstrasse 7, D-76829 Landau in der Pfalz (Germany); Eqani, Syed Ali Musstjab Akber Shah, E-mail: ali_ebl2@yahoo.com [Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021 (China); Public Health and Environment Division, Department of Biosciences, COMSATS Institute of Information Technology, Islamabad (Pakistan)

    2015-12-15

    The consumption of contaminated drinking water is one of the major causes of mortality and many severe diseases in developing countries. The principal drinking water sources in Pakistan, i.e. ground and surface water, are subject to geogenic and anthropogenic trace metal contamination. However, water quality monitoring activities have been limited to a few administrative areas and a nationwide human health risk assessment from trace metal exposure is lacking. Using geographically weighted regression (GWR) and eight relevant spatial predictors, we calculated nationwide human health risk maps by predicting the concentration of 10 trace metals in the drinking water sources of Pakistan and comparing them to guideline values. GWR incorporated local variations of trace metal concentrations into prediction models and hence mitigated effects of large distances between sampled districts due to data scarcity. Predicted concentrations mostly exhibited high accuracy and low uncertainty, and were in good agreement with observed concentrations. Concentrations for Central Pakistan were predicted with higher accuracy than for the North and South. A maximum 150–200 fold exceedance of guideline values was observed for predicted cadmium concentrations in ground water and arsenic concentrations in surface water. In more than 53% (4 and 100% for the lower and upper boundaries of 95% confidence interval (CI)) of the total area of Pakistan, the drinking water was predicted to be at risk of contamination from arsenic, chromium, iron, nickel and lead. The area with elevated risks is inhabited by more than 74 million (8 and 172 million for the lower and upper boundaries of 95% CI) people. Although these predictions require further validation by field monitoring, the results can inform disease mitigation and water resources management regarding potential hot spots. - Highlights: • Predictions of trace metal concentration use geographically weighted regression • Human health risk

  9. Linking trace element variations with macronutrients and major cations in marine mussels Mytilus edulis and Perna viridis.

    Science.gov (United States)

    Liu, Fengjie; Wang, Wen-Xiong

    2015-09-01

    Marine mussels have long been used as biomonitors of contamination of trace elements, but little is known about whether variation in tissue trace elements is significantly associated with those of macronutrients and major cations. The authors examined the variability of macronutrients and major cations and their potential relationships with bioaccumulation of trace elements. The authors analyzed the concentrations of macronutrients (C, N, P, S), major cations (Na, Mg, K, Ca), and trace elements (Al, V, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Mo, Cd, Ba, Pb) in the whole soft tissues of marine mussels Mytilus edulis and Perna viridis collected globally from 21 sites. The results showed that 12% to 84% of the variances in the trace elements was associated with major cations, and the tissue concentration of major cations such as Na and Mg in mussels was a good proxy for ambient seawater concentrations of the major cations. Specifically, bioaccumulation of most of the trace elements was significantly associated with major cations, and the relationships of major cations with trace cations and trace oxyanions were totally opposite. Furthermore, 14% to 69% of the variances in the trace elements were significantly associated with macronutrients. Notably, more than half of the variance in the tissue concentrations of As, Cd, V, Ba, and Pb was explained by the variance in macronutrients in one or both species. Because the tissue macronutrient concentrations were strongly associated with animal growth and reproduction, the observed coupling relationships indicated that these biological processes strongly influenced the bioaccumulation of some trace elements. The present study indicated that simultaneous quantification of macronutrients and major cations with trace elements can improve the interpretation of biomonitoring data. © 2015 SETAC.

  10. Instrumental trace element analysis of California market milk

    International Nuclear Information System (INIS)

    Ragaini, R.C.; Langhorst, A.L.; Ralston, H.R.; Heft, R.

    1975-01-01

    Trace element analysis for 15 elements (Zn, Na, Br, Rb, Sr, Mg, Al, Ca, Cl, I, K, Fe, Co, Se, Cs) was carried out on 32 samples of California market milk and 6 samples of Colorado milk in a pilot study of toxic and nutrient trace elements in the soil-forage-cow-milk food chain. The techniques of instrumental neutron activation analysis and x-ray fluorescence analysis are described. Sample collection, preparation, analysis, and data reduction procedures are discussed. The mean values and variations of trace element concentrations in milk are compared to data from other studies. (U.S.)

  11. Trace element exposure of whooper swans (Cygnus cygnus) wintering in a marine lagoon (Swan Lake), northern China.

    Science.gov (United States)

    Wang, Feng; Xu, Shaochun; Zhou, Yi; Wang, Pengmei; Zhang, Xiaomei

    2017-06-30

    Trace element poisoning remains a great threat to various waterfowl and waterbirds throughout the world. In this study, we determined the trace element exposure of herbivorous whooper swans (Cygnus cygnus) wintering in Swan Lake (Rongcheng), an important swan protection area in northern China. A total of 70 samples including abiotic factors (seawater, sediments), food sources (seagrass, macroalgae), feathers and feces of whooper swans were collected from the marine lagoon during the winters of 2014/2015 and 2015/2016. Concentrations of Cu, Zn, Pb, Cr, Cd, Hg and As were determined to investigate the trace element exposure of whooper swans wintering in the area. Results showed that there was an increasing trend in sediment trace element concentrations, compared with historical data. The trace element concentrations in swan feces most closely resembled those of Zostera marina leaves, especially for Cd and Cr. The Zn and Hg concentrations in the swan feces (49.57 and 0.01mg/kg, respectively) were lower than the minimum values reported in the literature for other waterfowls, waterbirds and terrestrial birds. However, the concentrations of the other five trace elements fell within the lower and mediate range of values reported for birds across the world. These results suggest that the whooper swans wintering in Swan Lake, Rongcheng are not suffering severe trace element exposure; however, with the increasing input of trace elements to the lagoon, severe adverse impacts may occur in the future, and we therefore suggest that the input of trace elements to this area should be curbed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Sensitive Mid-IR Laser Sensor Development and Mass Spectrometric Measurements in Shock Tube and Flames

    KAUST Repository

    Alquaity, Awad

    2016-01-01

    CRDS technique was utilized to develop an ultra-fast, high sensitivity diagnostic to monitor trace concentrations of ethylene in shock tube pyrolysis experiments. This diagnostic represented the first ever successful application of CRDS technique

  13. Consumption of ultra-processed food products and its effects on children's lipid profiles: a longitudinal study.

    Science.gov (United States)

    Rauber, F; Campagnolo, P D B; Hoffman, D J; Vitolo, M R

    2015-01-01

    Cardiovascular disease development is related to known risk factors (such as diet and blood lipids) that begin in childhood. Among dietary factors, the consumption of ultra-processing products has received attention. This study investigated whether children's consumption of processed and ultra-processing products at preschool age predicted an increase in lipid concentrations from preschool to school age. Cohort study conducted with 345 children of low socioeconomic status from São Leopoldo, Brazil, aged 3-4 years and 7-8 years. Blood tests were done to measure lipid profile. Dietary data were collected through 24-h recalls and the children's processed and ultra-processing product intake was assessed. Linear regression analysis was used to assess the relationship between processed and ultra-processed product intake at 3-4 years on changes in lipid concentrations from preschool to school age. The percentage of daily energy provided by processed and ultra-processed products was 42.6 ± 8.5 at preschool age and 49.2 ± 9.5 at school age, on average. In terms of energy intake, the main products consumed were breads, savoury snacks, cookies, candy and other sweets in both age groups. Ultra-processed product consumption at preschool age was a predictor of a higher increase in total cholesterol (β = 0.430; P = 0.046) and LDL cholesterol (β = 0.369; P = 0.047) from preschool to school age. Our data suggest that early ultra-processed product consumption played a role in altering lipoprotein profiles in children from a low-income community in Brazil. These results are important to understanding the role of food processing and the early dietary determinants of cardiovascular disease. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Trace elements concentrations in aquatic biota from the Iron Gates wetlands in Romania

    Directory of Open Access Journals (Sweden)

    Matache M. L.

    2013-04-01

    Full Text Available Concentration of four heavy metals was studied in living organisms from the wetlands ecosystems within the Iron Gates Natural Park in Romania. Samples included aquatic plants (Ceratophyllum ssp., Potamogeton pectinatus, Potamogeton natans, molluscs (Sinanodonta woodiana, Unio tumidus, Unio pictorum and fish (Silurus glanis, Sander lucioperca, Aspius aspius, Cyprinus carpio, Carassius gibelio. Metals organotropism in fish samples (gills, liver, muscle, eggs has been studied (Kojadinovici et al., 2007; Foata et. Al, 2009; Dutton and Fisher, 2011; David et al., 2012. Metal contamination of the wetlandecosystems in the Iron Gates Natural Park has been documented in the past for sediments (Matache et. al, 2002 and soils (Matache et al., 2003. This is a consequence of the mining and quarrying activities performed in the Moldova Noua region between 1960’s and 2000’s. Zinc is the main metal contaminant in all categories of collected samples. For fish muscle tissue (part of the fish mainly consumed by the local inhabitants, comparison with EU standards has been performed. Issues related to human health appear especially for cadmium (EC, 2006. Potamogeton pectinatus is the least accumulating plant species, whilst Potamogeton natans and Ceratophyllum ssp. had shown similar accumulation capacities of the trace elements.

  15. Determination of soluble ultra-trace metals and metalloids in rainwater and atmospheric deposition fluxes: a 2-year survey and assessment.

    Science.gov (United States)

    Montoya-Mayor, R; Fernández-Espinosa, A J; Seijo-Delgado, I; Ternero-Rodríguez, M

    2013-08-01

    The present work investigates the relationships between composition of rainwater and dry deposition fluxes by trace metals and metalloids. A modification in automatic "wet-only" and "dry-only" samplers was applied, which allowed the collection and conservation of samples separately. ICP-MS technique was used for the determination of analytes in samples. Concentrations of soluble elements in rainwater were measured directly in filtered samples. A sequential acid treatment with nitric, hydrofluoric and finally perchloric acids was used to measure the total contents of metals and metalloids in coarse particles. Variation between periods of heavy and light rains was assessed. Almost all of the metals and metalloids - B, Tl, Th, U, Al, Cs, Be, Ti and others - studied in dry deposition showed important decreases in concentrations (40-92%) during periods of heavy rainfall. Most of these metals and metalloids - As, Cr, Co, Ni - presented their highest levels (53-90%) in heavy rainfall periods in rainwater samples. Sources were identified in both types of samples collected using a new chemometric tool (SPCA). Urban traffic, surrounding contaminated soils and local anthropogenic sources were identified for rainwater samples. Natural and contaminated soils and general anthropogenic emissions were the sources identified for dry deposition fluxes. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Gold ultra-microelectrode arrays: application to the steady-state voltammetry of hydroxide ion in aqueous solution.

    Science.gov (United States)

    Ordeig, Olga; Banks, Craig E; Davies, Trevor J; del Campo, F Javier; Muñoz, Francesc Xavier; Compton, Richard G

    2006-05-01

    Gold ultra-microelectrode arrays are used to explore the electrochemical oxidation of hydroxide ions and are shown to be analytical useful. Two types of ultra-microelectrode arrays are used; the first consist of 256 individual electrodes of 5 microm in radius, 170 of which are electrochemically active in a cubic arrangement which are separated from their nearest neighbour by a distance of 100 microm. The second array compromises 2597 electrodes of 2.5 microm in radius and of which 1550 of which are electrochemically active in a hexagonal arrangement separated by the nearest neighbour by 55 microm. Well defined voltammetric waves are found with peak currents proportional to the concentration of hydroxide ions in the range 50 microM to 1 mM. Detection limits of 20 microM using the 170 ultra-microelectrode and 10 microM with the 1550 ultra-microelectrode array are shown to be possible but with a higher sensitivity of 4 mA M(-1) observed using the 1550 ultra-microelectrode array compared to 1.2 mA M(-1) with the 170 ultra-microelectrode array.

  17. Influence of trace elements in human tissue in low-energy photon brachytherapy dosimetry

    International Nuclear Information System (INIS)

    White, Shane A; Landry, Guillaume; Van Gils, Francis; Verhaegen, Frank; Reniers, Brigitte

    2012-01-01

    The aim of this paper is to determine the dosimetric impact of trace elements in human tissues for low-energy photon sources used in brachytherapy. Monte Carlo dose calculations were used to investigate the dosimetric effect of trace elements present in normal or cancerous human tissues. The effect of individual traces (atomic number Z = 11–30) was studied in soft tissue irradiated by low-energy brachytherapy sources. Three other tissue types (prostate, adipose and mammary gland) were also simulated with varying trace concentrations to quantify the contribution of each trace to the dose distribution. The dose differences between cancerous and healthy prostate tissues were calculated in single- and multi-source geometries. The presence of traces in a tissue produces a difference in the dose distribution that is dependent on Z and the concentration of the trace. Low-Z traces (Na) have a negligible effect ( 3%). There is a potentially significant difference in the dose distribution between cancerous and healthy prostate tissues (4%) and even larger if compared to the trace-free composition (15%) in both single- and multi-sourced geometries. Trace elements have a non-negligible (up to 8% in prostate D 90 ) effect on the dose in tissues irradiated with low-energy photon sources. This study underlines the need for further investigation into accurate determination of the trace composition of tissues associated with low-energy brachytherapy. Alternatively, trace elements could be incorporated as a source of uncertainty in dose calculations. (paper)

  18. Trace conditioning in insects-keep the trace!

    Science.gov (United States)

    Dylla, Kristina V; Galili, Dana S; Szyszka, Paul; Lüdke, Alja

    2013-01-01

    Trace conditioning is a form of associative learning that can be induced by presenting a conditioned stimulus (CS) and an unconditioned stimulus (US) following each other, but separated by a temporal gap. This gap distinguishes trace conditioning from classical delay conditioning, where the CS and US overlap. To bridge the temporal gap between both stimuli and to form an association between CS and US in trace conditioning, the brain must keep a neural representation of the CS after its termination-a stimulus trace. Behavioral and physiological studies on trace and delay conditioning revealed similarities between the two forms of learning, like similar memory decay and similar odor identity perception in invertebrates. On the other hand differences were reported also, like the requirement of distinct brain structures in vertebrates or disparities in molecular mechanisms in both vertebrates and invertebrates. For example, in commonly used vertebrate conditioning paradigms the hippocampus is necessary for trace but not for delay conditioning, and Drosophila delay conditioning requires the Rutabaga adenylyl cyclase (Rut-AC), which is dispensable in trace conditioning. It is still unknown how the brain encodes CS traces and how they are associated with a US in trace conditioning. Insects serve as powerful models to address the mechanisms underlying trace conditioning, due to their simple brain anatomy, behavioral accessibility and established methods of genetic interference. In this review we summarize the recent progress in insect trace conditioning on the behavioral and physiological level and emphasize similarities and differences compared to delay conditioning. Moreover, we examine proposed molecular and computational models and reassess different experimental approaches used for trace conditioning.

  19. ASBESTOS EXPOSURES DURING ROUTINE FLOOR TILE MAINTENANCE. PART 2: ULTRA HIGH SPEED BURNISHING AND WET-STRIPPING

    Science.gov (United States)

    This study was conducted to evaluate airborne asbestos concentrations during ultra high speed (UHS) burnishing and wet-stripping of asbestos-containing resilient floor tile under two levels of floor care condition (poor and good). Airborne asbestos concentrations were measured by...

  20. [Evaluation of Optium Xceed (Abbott) and One Touch Ultra (Lifescan) glucose meters].

    Science.gov (United States)

    Coyne, S; Lacour, B; Hennequin-Le Meur, C

    2008-01-01

    In order to build a continuous quality improvement approach for control of glucose meters in clinical divisions at Necker-Enfants Malades hospital, the analytical performances (precision and accuracy) of 2 glucose meters have been evaluated in our laboratory according to SFBC recommendations. Fifty-six heparinized whole blood specimens from patients and thirty-nine from healthy volunteers were analyzed on each of the two meters and compared to plasma glucose measurement on the Roche Hitachi 917 system. The correlation coefficient was 0.938 for Optium Xceed and 0.911 for One Touch Ultra. However, 14.7% and 18.9% of the results (n = 95) for respectively Optium Xceed and One Touch Ultra were discordant, i.e. higher than a 20% difference compared to reference blood glucose concentrations. Inaccuracy was more important for low glucose concentrations (glucose concentrations. Capillary blood glucose concentrations must therefore be interpreted with caution concerning the diagnosis of hypoglycemia and treatment of unstable patients. Moreover, quality control of glucose meters (blood glucose determinations concurrently at bedside and in the laboratory) is difficult to perform. It also raises questions about the responsibility of "point-of-care testing", an area still subject to discussion.

  1. Liquid phase microextraction for the analysis of trace elements and their speciation

    International Nuclear Information System (INIS)

    Hu, Bin; He, Man; Chen, Beibei; Xia, Linbo

    2013-01-01

    Trace/ultra-trace elements and their speciation analysis in complex matrices usually require sample preparation procedures to achieve sample clean-up and analyte preconcentration. Sample preparation is often the bottleneck in trace elements and their speciation analysis which has a direct impact on accuracy, precision and limits of detection and is often the rate-determining step of the analytical process. Recent trends in sample preparation include miniaturization, automation, high-throughput performance and reduction in solvent/sample consumption and operation time. Liquid-phase microextraction (LPME) technique as a novel and promising alternative in sample preparation can meet these requirements and has become a very efficient sample preparation technique. This review updates the state of art of LPME for trace elements and their speciation analysis and discusses its promising prospects. The major thrust of the article highlights the applications of LPME including single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid liquid microextraction (DLLME) and solidified floating organic drop microextraction (SFODME) to the fields of elemental and their speciation analysis by atomic spectrometry-based methods, especially inductively coupled plasma mass spectrometry. General and specific concepts, different extraction formats and characteristics of LPME are described and compared, along with examples of recent innovations and applications presented to demonstrate its potential for trace elements and their speciation analysis in biological and environmental fields. Moreover, the application potential and an outlook on the combination of LPME and atomic spectrometry-based techniques for inorganic analysis are commentated. - Highlights: • The state of art of LPME for trace elements and their speciation analysis is updated. • Different extraction formats of LPME are described. • The application potential and future

  2. Study of particle size and trace metal distribution in atmospheric aerosols of islamabad

    International Nuclear Information System (INIS)

    Shah, M.H.; Shaheen, N.

    2009-01-01

    Atmospheric aerosol samples were collected on glass fibre filters using high volume air samplers Half of each aerosol sample was solubilized in nitric acid/hydrochloric acid based wet digestion method and the concentration of trace metals was determined through flame atomic absorption spectrophotometer. Among the eight trace metals analyzed, mean concentration recorded for Zn (844 ng/m3), Fe (642 ng/m3) and Pb (253 ng/m3), was found to be higher than mean levels of Mn, Cr and Co. The size distribution of the collected particulate samples was carried out on mastersizer, which revealed PM/sub 100-10/ as the major fraction (55 %) followed by PM/sub 2.5-10/ (28 %). The correlation study evidenced a strong tendency of trace metals to be associated with fine particulate fractions. The atmospheric trace metal levels showed that the mean metal concentrations in the atmosphere of Islamabad are far higher than background and European urban sites mainly due to the anthropogenic emissions. (author)

  3. Trace elemental analysis of bituminous coals using the Heidelberg proton microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Chen, J R; Kneis, H; Martin, B; Nobiling, R; Traxel, K [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany, F.R.); Heidelberg Univ. (Germany, F.R.). Physikalisches Inst.); Chao, E C.T.; Minkin, J A [Geological Survey, Reston, VA (USA)

    1981-03-01

    Trace elements in coal can occur as components of either the organic constituents (macerals) or the inorganic constituents (minerals). Studies of the concentrations and distribution of the trace elements are vital to understanding the geochemical milieu in which the coal was formed and in evaluating the attempts to recover rare but technologically valuable metals. In addition, information on the trace element concentrations is important in predicting the environmental impact of burning particular coals, as many countries move toward greater utilization of coal reserves for energy production. Traditionally, the optical and the electron microscopes and more recently the electron microprobe have been used in studying the components of coal. The proton-induced X-ray emission (PIXE) microprobe offers a new complementary approach with an order of magnitude or more better minimum detection limit. We present the first measurements with a PIXE microprobe of the trace element concentrations of bituminous coal samples. Elemental analyses of the coal macerals-vitrinite, exinite, and inertinite - are discussed for three coal samples from the Eastern U.S.A., three samples from the Western U.S.A., and one sample from the Peoples Republic of China.

  4. Trace elements in home-produced eggs in Belgium: Levels and spatiotemporal distribution

    International Nuclear Information System (INIS)

    Waegeneers, Nadia; Hoenig, Michel; Goeyens, Leo; De Temmerman, Ludwig

    2009-01-01

    The purpose of this study was to evaluate the levels of arsenic, cadmium, lead, copper and zinc in home-produced eggs, soils and kitchen waste samples of private chicken owners in Belgium, and to determine spatiotemporal differences in trace element contents in eggs. Eggs were sampled in all provinces of Belgium in autumn 2006 and spring 2007. A total number of 59 private chicken owners participated in the study. Trace elements were determined by inductively coupled plasma-mass spectrometry except for mercury, which was determined by atomic absorption of mercury vapour. The mean fresh weight concentrations in eggs in autumn and spring respectively were < 8.0 and < 8.0 μg/kg for arsenic, 0.5 and < 0.5 μg/kg for cadmium, 116 and 74 μg/kg for lead, 0.43 and 0.52 mg/kg for copper, 20.3 and 19.2 mg/kg for zinc, and 3.15 and 4.44 μg/kg for mercury. Analysis of variance determined significant differences in some trace element concentrations in eggs among seasons and regions in Belgium. Average concentrations of arsenic, cadmium and mercury corresponded well with values measured in other countries, while copper and zinc concentrations were within the same order of magnitude as in other countries. Average lead concentrations were high compared to concentrations in eggs from other countries and correlated well with lead concentrations in soil, indicating that the soil is an important source. Other sources of trace elements in eggs might be home-grown vegetables and forage (grass and herbs), and indirectly, air pollution.

  5. Determination of Trace Anions in Concentrated Hydrogen Peroxide by Direct Injection Ion Chromatography with Conductivity Detection after Pt-Catalyzed On-Line Decomposition

    International Nuclear Information System (INIS)

    Kim, Do Hee; Lee, Bo Kyung; Lee, Dong Soo

    1999-01-01

    A method has been developed for the determination of trace anion impurities in concentrated hydrogen peroxide. The method involves on-line decomposition of hydrogen peroxide, ion chromatographic separation and subsequent suppressed-type conductivity detection. H 2 O 2 is decomposed in Pt-catalyst filled Gore-Tex membrane tubing and the resulting aqueous solution containing analytes is introduced to the injection valve of an ion chromatograph for periodic determinations. The oxygen gas evolving within the membrane tubing escapes freely through the membrane wall causing no problem in ion chromatographic analysis. Decomposition efficiency is above 99.99% at a flow rate of 0.4mL/min for a 30% hydrogen peroxide concentration. Analytes are quantitatively retained. The analysis results for several brands of commercial hydrogen peroxides are reported

  6. Composition of Trace Metals in Dust Samples Collected from Selected High Schools in Pretoria, South Africa

    Directory of Open Access Journals (Sweden)

    J. O. Olowoyo

    2016-01-01

    Full Text Available Potential health risks associated with trace metal pollution have necessitated the importance of monitoring their levels in the environment. The present study investigated the concentrations and compositions of trace metals in dust samples collected from classrooms and playing ground from the selected high schools In Pretoria. Schools were selected from Pretoria based on factors such as proximity to high traffic ways, industrial areas, and residential areas. Thirty-two dust samples were collected from inside and outside the classrooms, where learners often stay during recess period. The dust samples were analysed for trace metal concentrations using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS. The composition of the elements showed that the concentrations of Zn were more than all other elements except from one of the schools. There were significant differences in the concentrations of trace metals from the schools (p<0.05. Regular cleaning, proximity to busy road, and well maintained gardens seem to have positive effects on the concentrations of trace metals recorded from the classrooms dust. The result further revealed a positive correlation for elements such as Pb, Cu, Zn, Mn, and Sb, indicating that the dust might have a common source.

  7. Trace elements in Taiwanese diet in different seasons

    International Nuclear Information System (INIS)

    Sheng-Ming Liu; Chien Chung

    1992-01-01

    The trace element contents of Taiwanese diet were determined using conventional neutron activation analysis. Sample were prepared with duplicate portion technique by collecting food items ate and drank during a 3 day period in winter. Samples were homogenized, freeze-dried, and elemental concentration of trace elements were determined by instrumental neutron activation analysis. The interference from fast neutron induced reactions were corrected. Concentrations and daily dietary intake of the elements were compared with those collected in the summer, resulting less daily intake of K, Ca, Mn, Fe and Zn among Taiwanese than the values recommended by WHO and RDA. Alarming low intake of Fe for females and Zn among Taiwanese were indicated. (author) 6 refs.; 2 figs.; 5 tabs

  8. A practice of ultra-fine tailings disposal as filling material in a gold mine.

    Science.gov (United States)

    Deng, D Q; Liu, L; Yao, Z L; Song, K I-I L; Lao, D Z

    2017-07-01

    A practice of cemented backfill technology with ultra-fine tailings in a gold mine was comprehensively presented, and a series of tests were conducted in accordance with the peculiar properties of ultra-fine tailings and the mining technology conditions. The test results show that, the tailings from Shuiyindong Gold Mine have a great grinding fineness, with the average particle diameter 22.03 μm, in which the ultra-fine particles with the diameter below 20 μm occupying 66.13%. The analysis results of chemical components of tailings indicate that the content of SiO 2 is relatively low, i.e., 33.08%, but the total content of CaO, MgO and Al 2 O 3 is relatively high i.e., 36.5%. After the settlement of 4-6 h, the tailing slurry with the initial concentration of 40% has the maximum settling concentration of 54.692%, and the corresponding maximum settling unit weight is 1.497 g/cm 3 . During the field application, the ultra-fine tailings and PC32.5 cement were mixed with the cement-tailings ratios of 1:3-1:8, and the slurry concentration of 50 wt% was prepared. Using the slurry pump, the prepared cemented backfill slurries flowed into the goaf, and then the strength of the cemented backfill body met the mining technique requirements in Shuiyindong Gold Mine, where the ore body has a smooth occurrence, with the average thickness of approximately 2 m and the inclination angle ranging from 5 to 10°. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Concentrations of metals and trace elements in aquatic biota associated with abandoned mine lands in the Whiskeytown National Recreation Area and nearby Clear Creek watershed, Shasta County, northwestern California, 2002-2003

    Science.gov (United States)

    Hothem, Roger L.; May, Jason T.; Gibson, Jennifer K.; Brussee, Brianne E.

    2015-01-01

    Park management of the Whiskeytown National Recreation Area, in northwestern California, identified a critical need to determine if mercury (Hg) or other elements originating from abandoned mines within the Upper Clear Creek watershed were present at concentrations that might adversely affect aquatic biota living within the park. During 2002–03, the U.S. Geological Survey, in cooperation with the National Park Service, collected aquatic invertebrates, amphibians, and fish, and analyzed them for Hg, cadmium, zinc, copper, and other metals and trace elements. The data from the biota, in conjunction with data from concurrent community bioassessments, habitat analyses, water quality, and concentrations of metals and trace elements in water and sediment, were used to identify contamination “hot spots.”

  10. Determination of trace gold in rocks and minerals by neutron activation analysis

    International Nuclear Information System (INIS)

    Zhao Yunlong; Zhou Suqing; Liang Yutang

    1988-05-01

    The determination of trace gold in rocks and minerals by neutron activation analysis is described. Two methods are used for pre-separating and concentrating the trace gold in geological samples. one of the methods is that the samples are dissolved in aqua regia solution; activated carbon paper pulp filter is used for pre-separating and concentrating trace gold by dynamic adsorption method; then the activated carbon containing gold was ashed at 650 ∼ 700 deg c. The other method is that the samples are dissolved in aqua regia solution; the polyurethane foam plastic filled with activated carbon is used for pre-separating and concentrating trace gold by dynamic adsorption method; then the foam plastic containing gold was ashed at 650 deg c. The gold in ashes is determinated by neutron activation analysis. The detection limit is 0.004ng/g. The accuracy of the method is examined by gold in reference standard material. The results of this method are in good agreement with the recommended value. For analysis of the trace gold by the methods of instrumental neutron activation analysis and epithermal neutron activation analysis, the interference of 411.8 keV γ-ray from 153 Sm, 152 Eu and fission products of uranium and the correction methods are discussed

  11. Investigation of the response of Lexan polycarbonate to relativistic ultra heavy nuclear particles

    CERN Document Server

    Keane, A J; O'Sullivan, D

    1999-01-01

    Recent investigations of the track response of Lexan to relativistic ultra heavy nuclei are reported. The inherent charge resolution of Lexan for relativistic ultra heavy nuclei under normal exposure conditions at accelerators has been investigated. The registration temperature effect was measured using gold (Z=79) at energies 2, 4 and 11 GeV/u covering a wide range of temperatures from -78 deg. C to +22 deg. C. In addition, the sensitivity of the track etch rate and the bulk etch rate to etch product concentration was re-examined.

  12. Investigation of the response of Lexan polycarbonate to relativistic ultra heavy nuclear particles

    International Nuclear Information System (INIS)

    Keane, A.J.; Thompson, A.; O'Sullivan, D.

    1999-01-01

    Recent investigations of the track response of Lexan to relativistic ultra heavy nuclei are reported. The inherent charge resolution of Lexan for relativistic ultra heavy nuclei under normal exposure conditions at accelerators has been investigated. The registration temperature effect was measured using gold (Z=79) at energies 2, 4 and 11 GeV/u covering a wide range of temperatures from -78 deg. C to +22 deg. C. In addition, the sensitivity of the track etch rate and the bulk etch rate to etch product concentration was re-examined

  13. Trace elements in two marine fish cultured in fish cages in Fujian province, China

    International Nuclear Information System (INIS)

    Onsanit, Sarayut; Ke Caihuan; Wang Xinhong; Wang Kejian; Wang Wenxiong

    2010-01-01

    Two cultured marine fish, the Japanese seabass (Lateolabrax japonicus) and red seabream (Pagrus major) were collected from eight fish cage sites along the coast of Fujian province in China. The concentrations of Ag, As, Cd, Co, Cu, Fe, Mn, Se, and Zn in their muscle, stomach and liver tissue were quantified. The risk of these trace elements to humans through fish consumption was then assessed. The highest concentrations of As, Cd, Se and Zn in fish feed from fish cages were found in Dongshan Station. Moreover, the As levels in the muscles of both species at all sites were generally higher than China's national standard (>1.0 μg/g). Trace element concentrations in two marine fish followed the order of livers > stomachs > muscles. Although the As levels in two marine caged fish exceeded the permissible standards, the estimated daily intake of As did not exceed the reference dose guideline established by US EPA. For other trace elements examined in this study, their concentrations did not exceed the permissible concentrations of the international standards. - As levels in two marine caged fish from China exceeded the permissible standards, whereas the levels of others trace elements did not exceed the permissible concentrations.

  14. Physiology and Pathophysiology in Ultra-Marathon Running

    Directory of Open Access Journals (Sweden)

    Beat Knechtle

    2018-06-01

    Full Text Available In this overview, we summarize the findings of the literature with regards to physiology and pathophysiology of ultra-marathon running. The number of ultra-marathon races and the number of official finishers considerably increased in the last decades especially due to the increased number of female and age-group runners. A typical ultra-marathoner is male, married, well-educated, and ~45 years old. Female ultra-marathoners account for ~20% of the total number of finishers. Ultra-marathoners are older and have a larger weekly training volume, but run more slowly during training compared to marathoners. Previous experience (e.g., number of finishes in ultra-marathon races and personal best marathon time is the most important predictor variable for a successful ultra-marathon performance followed by specific anthropometric (e.g., low body mass index, BMI, and low body fat and training (e.g., high volume and running speed during training characteristics. Women are slower than men, but the sex difference in performance decreased in recent years to ~10–20% depending upon the length of the ultra-marathon. The fastest ultra-marathon race times are generally achieved at the age of 35–45 years or older for both women and men, and the age of peak performance increases with increasing race distance or duration. An ultra-marathon leads to an energy deficit resulting in a reduction of both body fat and skeletal muscle mass. An ultra-marathon in combination with other risk factors, such as extreme weather conditions (either heat or cold or the country where the race is held, can lead to exercise-associated hyponatremia. An ultra-marathon can also lead to changes in biomarkers indicating a pathological process in specific organs or organ systems such as skeletal muscles, heart, liver, kidney, immune and endocrine system. These changes are usually temporary, depending on intensity and duration of the performance, and usually normalize after the race. In

  15. Galaxy collisions as a mechanism of ultra diffuse galaxy (UDG) formation

    Science.gov (United States)

    Baushev, A. N.

    2018-04-01

    We suggest a possible mechanism of ultra diffuse galaxy formation: the UDGs may occur as a result of a central collision of galaxies. If the galaxies are young and contain a lot of gas, the collision may kick all the gas off the systems and thus strongly suppress any further star formation. As a result, the galaxies now have a very low surface brightness and other properties typical of the ultra diffuse galaxies. We use the Coma cluster (where numerous UDGs were recently discovered) to test the efficiency of the process. The mechanism works very well and can transform a significant fraction of the cluster population into ultra diffuse galaxies. The UDGs formed by the process concentrate towards the center of the cluster, and their globular cluster systems remain undamaged, in accordance with observational results. The projected surface density of UDGs in the cluster may help us to recognize the mechanism of UDG formation, or clarify relative contributions of several possible competitive mechanisms at work.

  16. Electric discharge for treatment of trace contaminants

    Science.gov (United States)

    Flamm, D. L.; Wydeven, T. J. (Inventor)

    1978-01-01

    A radio frequency glow discharge reactor is described for removing trace oxidizable contaminants from an oxygen bearing atmosphere. The reaction chamber is defined by an inner metal electrode facing a dielectric backed by an outer conductive electrode. In one embodiment, a conductive liquid forms the conductor of an outer electrode and cools the dielectric. A resonator coupled to a variable radio frequency source generates the high voltages for creating a glow discharge in the chamber at a predetermined pressure whereby the trace contaminants are oxidized into a few simple non-toxic products that may be easily recovered. The corresponding process for removal of trace contaminants from an oxygen-bearing atmosphere with high efficiency independent of the concentration level is also disclosed.

  17. Trace detection of tetrahydrocannabinol (THC) with a SERS-based capillary platform prepared by the in situ microwave synthesis of AgNPs.

    Science.gov (United States)

    Yüksel, Sezin; Schwenke, Almut M; Soliveri, Guido; Ardizzone, Silvia; Weber, Karina; Cialla-May, Dana; Hoeppener, Stephanie; Schubert, Ulrich S; Popp, Jürgen

    2016-10-05

    In the present study, an ultra-sensitive and highly reproducible novel SERS-based capillary platform was developed and utilized for the trace detection of tetrahydrocannabinol (THC). The approach combines the advantages of microwave-assisted nanoparticle synthesis, plasmonics and capillary forces. By employing a microwave-assisted preparation method, glass capillaries were reproducibly coated with silver nanoparticles in a batch fabrication process that required a processing time of 3 min without needing to use any pre-surface modifications or add surfactants. The coated capillaries exhibited an excellent SERS activity with a high reproducibility and enabled the detection of low concentrations of target molecules. At the same time, only a small amount of analyte and a short and simple incubation process was required. The developed platform was applied to the spectroscopic characterization of tetrahydrocannabinol (THC) and its identification at concentration levels down to 1 nM. Thus, a highly efficient detection system for practical applications, e.g., in drug monitoring/detection, is introduced, which can be fabricated at low cost by using microwave-assisted batch synthesis techniques. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Ultra-sensitive "turn-on" detection method for Hg(2+) based on mispairing biosensor and emulsion PCR.

    Science.gov (United States)

    Zhu, Pengyu; Tian, Wenying; Cheng, Nan; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2016-08-01

    Sensor-based detection methods have inspired the idea that chemical or physical signals could be converted to nucleic acid signals to be quantitatively detected using a combination of appropriate detection tools. To achieve ultra-sensitive and absolute quantitative detection of mercury ion (Hg(2+)), we have combined a mispairing biosensor for Hg(2+) and emulsion PCR. The parameters that might influence the biosensor step, such as the duration of isothermal amplification and the concentration of the sensor oligonucleotide, have been firstly optimized in our study to achieve the most efficient biosensor detection. The evaluation results of secondary structures between the biosensors with different number of T-Hg-T structures achieved by Circular Dichroism have indicated that the secondary hairpin structure would be varied according to the change of number of T-Hg-T structures, which could influence the quantitative detection results. Further optimization of number of T-Hg-T within the biosensor sequences showed that 5 T-Hg-T structures could generate the most efficient amplification. After the above optimizations, the emulsion PCR has been employed to achieve the absolute quantitation of nucleic acid signals. The final results have shown that the limit of quantitation (LOQ) in our study was as low as 40fmol, and the limit of detection (LOD) was 10fmol. The practical detection tests showed that the quantitative results were stable and accurate for all substrates. In conclusion, by combining a mispairing biosensor with emulsion PCR, we developed a flexible and stable quantitative "turn-on" detection method with ultra-sensitivity that can detect trace amounts Hg(2+) within different substrates. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Soil amendments reduce trace element solubility in a contaminated soil and allow regrowth of natural vegetation

    International Nuclear Information System (INIS)

    Madejon, Engracia; Perez de Mora, Alfredo; Felipe, Efrain; Burgos, Pilar; Cabrera, Francisco

    2006-01-01

    We tested the effects of three amendments (a biosolid compost, a sugar beet lime, and a combination of leonardite plus sugar beet lime) on trace element stabilisation and spontaneous revegetation of a trace element contaminated soil. Soil properties were analysed before and after amendment application. Spontaneous vegetation growing on the experimental plot was studied by three surveys in terms of number of taxa colonising, percentage vegetation cover and plant biomass. Macronutrients and trace element concentrations of the five most frequent species were analysed. The results showed a positive effect of the amendments both on soil chemical properties and vegetation. All amendments increased soil pH and TOC content and reduced CaCl 2 -soluble-trace element concentrations. Colonisation by wild plants was enhanced in all amended treatments. The nutritional status of the five species studied was improved in some cases, while a general reduction in trace element concentrations of the aboveground parts was observed in all treated plots. The results obtained show that natural assisted remediation has potential for success on a field scale reducing trace element entry in the food chain. - Soil amendments affect soil chemistry and allow revegetation of soils contaminated by trace elements

  20. Study of trace elements distribution in various tissues structures

    International Nuclear Information System (INIS)

    Kwiatek, W.M.; Marczewska, E.

    1994-01-01

    Many papers have been written during the past ten years about TE study in cancer and normal tissues describing the use of different methods for detection of trace elements. Concentration of TE depends strongly on the sample measured. However, according to our knowledge, the role of TE in cancerous tissue is still known. Therefore, we propose to perform an experiment which will hopefully given us more information about the relationship between the concentration of elements in different tissues. The developing industry localised near Cracow becomes a serious danger for health of it's inhabitants. The negative influence of the air pollution to the living organisms is seen not only in the nature but also in humans. Therefore we want to analyse the trace element contents in the air. Such investigation will give the information about the pollution level in the City. The pollution has its obvious negative influence to health and toxic element concentration level in blood. It is interesting to check if placenta plays an effective role in foetus protection against toxic metals. In order to study this problem, the trace element analysis of placenta tissues will be done by means of synchrotron microbeam. (author). 1 ref

  1. Ionic liquid solvent bar micro-extraction of CdCln(n-2)- species for ultra-trace Cd determination in seawater.

    Science.gov (United States)

    Herce-Sesa, Belén; López-López, José A; Moreno, Carlos

    2018-02-01

    Water analysis of trace metals has been benefited by recent studies on sample preparation by liquid micro-extraction. However, there are still limitations for its application to seawater, such as the need of additives to preserve the sample or the availability of chemical extractants for the selective extraction from highly saline samples. In this work, a three phase solvent bar micro-extraction (3SBME) system containing the ionic liquid trioctylmethylammonium chloride (Aliquat ® 336) has been used for isolation and pre-concentration of Cd from seawater samples, due to its ability for ionic exchange of CdCl n (n-2)- . The system was optimized to work at the natural pH of seawater, and conditions for application to real samples were 0.18 M Aliquat ® 336 dissolved in kerosene with 0.25 M dodecan-1-ol as organic solution, 1.5 M HNO 3 as acceptor solution, 60 min extraction time, and 800 rpm stirring speed in the sample. Loss of organic solution into the sample during extraction was evaluated and revealed its dependence on stirring rate and extraction time. Under optimum conditions samples containing Cd 0.09-0.90 nM were pre-concentrated 65 times. GF-AAS was used for metal quantification with a limit of detection of 0.04 nM. Accuracy was successfully evaluated measuring Cd in a seawater certified reference material BCR-403. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Trace element distributions in aquatic sediments of Danang - Hoian area, Vietnam

    Energy Technology Data Exchange (ETDEWEB)

    Thuy, H.T.T.; Tobschall, H.J. [Erlangen-Nuernberg Univ., Erlangen (Germany). Inst. fuer Geologie und Mineralogie; An, P.V. [University of Mining and Geology, Hanoi (Viet Nam)

    2000-05-01

    Distribution of the trace elements Cr, Cu, Ni, Pb and Zn in surficial sediments of the river/sea environment in Danang - Hoian area (Vietnam) was investigated to examine the degree of metal pollution caused by anthropogenic activities. Point sources from domestic and industrial wastes are identified as dominant contributors of trace element accumulation. Surficial sediments of Hoian River show extremely high total concentrations of Cu (Average Concentration 295 {mu}g/g), Ni (AC 112 {mu}g/g), Pb (AC 396 {mu}g/g) and Zn (AC 429 mug/g) that exceed assigned safety levels ER-M. Similarly, the sediments of Han River show high Pb (AC 188 {mu}g/g) and Zn (AC 282 {mu}g/g) contents. In marine sediments of Thanhbinh beach Pb is also enriched (138 {mu}g/g) above guideline levels. In contrast the sediments of the Cude River are dominated by trace element concentrations close to background values. (orig.)

  3. Dietary patterns and trace elements intake evaluation

    International Nuclear Information System (INIS)

    Rahman, A.; Waheed, S.; Zaidi, J.H.; Ahmad, S.

    1998-01-01

    The dietary patterns and trace element contents of the integrated diets of middle income population in Gujranwala and of Islamabad have been studied and dietary intake of winter and summer are given. An overview of the elemental concentration in the two sets of integrated diets reveals similar zinc and manganese concentrations; comparatively higher nickel, selenium and potassium concentrations in Gujranwala and higher chromium, cesium, scandium, sodium and chlorine concentrations in Islamabad. These results undoubtedly reflect the difference in food selection and habits of the two populations, the influence of soil content and industrial pollution

  4. Trace elements in coloured opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1995-01-01

    Neutron activation analysis was used to determine the concentration of trace elements in 50 samples of orange, yellow, honey, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were evaluated to determine the relationship between trace elements content and opal colour. (author). 10 refs., 10 figs., 3 tabs

  5. Trace Elements in Cardiovascular Diseases

    Energy Technology Data Exchange (ETDEWEB)

    Masironi, R. [Cardiovascular Diseases Unit, World Health Organization, Geneva (Switzerland)

    1970-07-01

    Cardiovascular diseases are the leading cause of death in industrialized countries. Their incidence increases, apparently, as a, function of technological progress so that in the future they may become a major public health problem in developing countries too. Early diagnosis and prevention are the tools best suited to curb such an alarming trend, but our knowledge of these topics is unsatisfactory, Valuable information would be obtained through a systematic investigation of trace elements in relation to cardiovascular function and to various types of cardiovascular diseases. Such studies would provide clues to the following questions: 1. Why does the incidence and type of cardiovascular disease differ from one country to another? May this be related to differences in tissue mineral concentrations among various population groups? 2. Which trace elements if any are beneficial to cardiovascular health, and which are harmful ones that may act as aetiological agents for some cardiovascular diseases? 3. Is it possible to utilize measurements of mineral element concentration for diagnostic purposes in cardiovascular disease? (author)

  6. Effects of elevated CO2 concentrations and fly ash amended soils on trace element accumulation and translocation among roots, stems and seeds of Glycine max (L.) Merr

    International Nuclear Information System (INIS)

    Rodriguez, J.H.; Klumpp, A.; Fangmeier, A.; Pignata, M.L.

    2011-01-01

    The carbon dioxide (CO 2 ) levels of the global atmosphere and the emissions of heavy metals have risen in recent decades, and these increases are expected to produce an impact on crops and thereby affect yield and food safety. In this study, the effects of elevated CO 2 and fly ash amended soils on trace element accumulation and translocation in the root, stem and seed compartments in soybean [Glycine max (L.) Merr.] were evaluated. Soybean plants grown in fly ash (FA) amended soil (0, 1, 10, 15, and 25% FA) at two CO 2 regimes (400 and 600 ppm) in controlled environmental chambers were analyzed at the maturity stage for their trace element contents. The concentrations of Br, Co, Cu, Fe, Mn, Ni, Pb and Zn in roots, stems and seeds in soybeans were investigated and their potential risk to the health of consumers was estimated. The results showed that high levels of CO 2 and lower concentrations of FA in soils were associated with an increase in biomass. For all the elements analyzed except Pb, their accumulation in soybean plants was higher at elevated CO 2 than at ambient concentrations. In most treatments, the highest concentrations of Br, Co, Cu, Fe, Mn, and Pb were found in the roots, with a strong combined effect of elevated CO 2 and 1% of FA amended soils on Pb accumulation (above maximum permitted levels) and translocation to seeds being observed. In relation to non-carcinogenic risks, target hazard quotients (TQHs) were significant in a Chinese individual for Mn, Fe and Pb. Also, the increased health risk due to the added effects of the trace elements studied was significant for Chinese consumers. According to these results, soybean plants grown for human consumption under future conditions of elevated CO 2 and FA amended soils may represent a toxicological hazard. Therefore, more research should be carried out with respect to food consumption (plants and animals) under these conditions and their consequences for human health.

  7. Effects of elevated CO2 concentrations and fly ash amended soils on trace element accumulation and translocation among roots, stems and seeds of Glycine max (L.) Merr.

    Science.gov (United States)

    Rodriguez, J H; Klumpp, A; Fangmeier, A; Pignata, M L

    2011-03-15

    The carbon dioxide (CO(2)) levels of the global atmosphere and the emissions of heavy metals have risen in recent decades, and these increases are expected to produce an impact on crops and thereby affect yield and food safety. In this study, the effects of elevated CO(2) and fly ash amended soils on trace element accumulation and translocation in the root, stem and seed compartments in soybean [Glycine max (L.) Merr.] were evaluated. Soybean plants grown in fly ash (FA) amended soil (0, 1, 10, 15, and 25% FA) at two CO(2) regimes (400 and 600 ppm) in controlled environmental chambers were analyzed at the maturity stage for their trace element contents. The concentrations of Br, Co, Cu, Fe, Mn, Ni, Pb and Zn in roots, stems and seeds in soybeans were investigated and their potential risk to the health of consumers was estimated. The results showed that high levels of CO(2) and lower concentrations of FA in soils were associated with an increase in biomass. For all the elements analyzed except Pb, their accumulation in soybean plants was higher at elevated CO(2) than at ambient concentrations. In most treatments, the highest concentrations of Br, Co, Cu, Fe, Mn, and Pb were found in the roots, with a strong combined effect of elevated CO(2) and 1% of FA amended soils on Pb accumulation (above maximum permitted levels) and translocation to seeds being observed. In relation to non-carcinogenic risks, target hazard quotients (TQHs) were significant in a Chinese individual for Mn, Fe and Pb. Also, the increased health risk due to the added effects of the trace elements studied was significant for Chinese consumers. According to these results, soybean plants grown for human consumption under future conditions of elevated CO(2) and FA amended soils may represent a toxicological hazard. Therefore, more research should be carried out with respect to food consumption (plants and animals) under these conditions and their consequences for human health. Copyright © 2010

  8. Trace elements at the intersection of marine biological and geochemical evolution

    Science.gov (United States)

    Robbins, Leslie J.; Lalonde, Stefan V.; Planavsky, Noah J.; Partin, Camille A.; Reinhard, Christopher T.; Kendall, Brian; Scott, Clinton T.; Hardisty, Dalton S.; Gill, Benjamin C.; Alessi, Daniel S.; Dupont, Christopher L.; Saito, Mak A.; Crowe, Sean A.; Poulton, Simon W.; Bekker, Andrey; Lyons, Timothy W.; Konhauser, Kurt O.

    2016-01-01

    Life requires a wide variety of bioessential trace elements to act as structural components and reactive centers in metalloenzymes. These requirements differ between organisms and have evolved over geological time, likely guided in some part by environmental conditions. Until recently, most of what was understood regarding trace element concentrations in the Precambrian oceans was inferred by extrapolation, geochemical modeling, and/or genomic studies. However, in the past decade, the increasing availability of trace element and isotopic data for sedimentary rocks of all ages has yielded new, and potentially more direct, insights into secular changes in seawater composition – and ultimately the evolution of the marine biosphere. Compiled records of many bioessential trace elements (including Ni, Mo, P, Zn, Co, Cr, Se, and I) provide new insight into how trace element abundance in Earth's ancient oceans may have been linked to biological evolution. Several of these trace elements display redox-sensitive behavior, while others are redox-sensitive but not bioessential (e.g., Cr, U). Their temporal trends in sedimentary archives provide useful constraints on changes in atmosphere-ocean redox conditions that are linked to biological evolution, for example, the activity of oxygen-producing, photosynthetic cyanobacteria. In this review, we summarize available Precambrian trace element proxy data, and discuss how temporal trends in the seawater concentrations of specific trace elements may be linked to the evolution of both simple and complex life. We also examine several biologically relevant and/or redox-sensitive trace elements that have yet to be fully examined in the sedimentary rock record (e.g., Cu, Cd, W) and suggest several directions for future studies.

  9. Bio-optical characterization in an ultra-oligotrophic region: the North central Red Sea

    KAUST Repository

    Kheireddine, Malika; Jones, Burton

    2015-01-01

    are derived from the concentration and physical properties of suspended particles in the ocean. They provide a simple description of the influence of these particles on the light within the water column. Bio-optical relationships found for ultra

  10. Effect of fouling on removal of trace organic compounds by nanofiltration

    Directory of Open Access Journals (Sweden)

    S. Hajibabania

    2011-12-01

    Full Text Available The fate of chemical of concern is not yet fully understood during treatment of impaired waters. The aim of this paper is to assess the impact of different organic-based fouling layers on the removal of a large range of trace organics. Both model and real water samples (mixed with trace organic contaminants at environmental concentration of 2 μg l−1 were used to simulate fouling in nanofiltration under controlled environment. The new and fouled membranes were systematically characterised for surface charge, hydrophobicity and roughness. It was observed that fouling generally reduced the membrane surface charge; however, the alterations of the membrane hydrophobicity and surface roughness were dependent on the foulants composition. The rejection of charged trace organics was observed to be improved due to the increased electrostatic repulsion by fouled membranes and the adsorption of the trace organic chemicals onto organic matters. On the other hand, the removal of nonionic compounds decreased when fouling occurred, due to the presence of cake enhanced concentration polarization. The fouling layer structure was found to play an important role in the rejection of the trace organic compounds.

  11. On nutrients and trace metals: Effects from Enhanced Weathering

    Science.gov (United States)

    Amann, T.; Hartmann, J.

    2015-12-01

    The application of rock flour on suitable land ("Enhanced Weathering") is one proposed strategy to reduce the increase of atmospheric CO2 concentrations. At the same time it is an old and established method to add fertiliser and influence soil properties. Investigations of this method focused on the impact on the carbonate system, as well as on engineering aspects of a large-scale application, but potential side effects were never discussed quantitatively. We analysed about 120,000 geochemically characterised volcanic rock samples from the literature. Applying basic statistics, theoretical release rates of nutrients and potential contaminants by Enhanced Weathering were evaluated for typical rock types. Applied rock material can contain significant amounts of essential or beneficial nutrients (potassium, phosphorus, micronutrients). Their release can partly cover the demand of major crops like wheat, rice or corn, thereby increasing crop yield on degraded soils. However, the concentrations of considered elements are variable within a specific rock type, depending on the geological setting. High heavy metal concentrations are found in (ultra-) basic rocks, the class with the highest CO2 drawdown potential. More acidic rocks contain less or no critical amounts, but sequester less CO2. Findings show that the rock selection determines the capability to supply significant amounts of nutrients, which could partly substitute industrial mineral fertiliser usage. At the same time, the release of harmful trace element has to be considered. Through careful selection of regionally available rocks, benefits could be maximised and drawbacks reduced. The deployment of Enhanced Weathering to sequester CO2 and to ameliorate soils necessitates an ecosystem management, considering the release and fate of weathered elements in plants, soils and water. Cropland with degraded soils would benefit while having a net negative CO2 effect, while other carbon dioxide removal strategies, like

  12. Distribution and concentration evaluation of trace and rare earth elements in sediment samples of the Billings and Guarapiranga reservoir systems

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Larissa S.; Fávaro, Déborah I.T., E-mail: defavaro@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (LAN-CRPq/IPEN/CNEN-SP), São Paulo(Brazil). Lab. de Análise por Ativação Neutrônica; Ferreira, Francisco J. [Companhia Ambiental do Estado de São Paulo (ELAI/CETESB), Sao Paulo, SP (Brazil). Setor de Química Inorgânica

    2017-07-01

    Concentration and distribution of trace and rare earth elements in bottom sediment samples collected in the Billings System (including Rio Grande and Guarapiranga Reservoirs) were assessed by using Instrumental Neutron Activation (INAA). To evaluate the sources of anthropogenic contamination the enrichment factor (FE) and the geoacumulation index (IGeo) were calculated using NASC and Guarapiranga Park Soil as Reference Values. Results were compared to the concentration guideline values established by CCME (Canadian Council of Ministers of the Environment) environmental agency for As, Cr and Zn, and values in other published studies. Most points exceeded TEL values and, in some points, PEL values for these elements, indicating poor sediment quality in these reservoirs. In general terms, the elements As, Cr, Sb and Zn through EF and IGeo calculations present enrichment at all points analyzed, in both collection campaigns, except for the Rio Grande Reservoir points. The region where the reservoirs are located receive untreated sewage as well as pollution from urban occupation, industrial and mining activities, making it difficult to accurately identify the pollution sources. This study found higher concentrations of the elements analyzed in the Billings Reservoir, indicating a greater contamination level in relation to the other reservoirs. (author)

  13. Distribution and concentration evaluation of trace and rare earth elements in sediment samples of the Billings and Guarapiranga reservoir systems

    International Nuclear Information System (INIS)

    Silva, Larissa S.; Fávaro, Déborah I.T.; Ferreira, Francisco J.

    2017-01-01

    Concentration and distribution of trace and rare earth elements in bottom sediment samples collected in the Billings System (including Rio Grande and Guarapiranga Reservoirs) were assessed by using Instrumental Neutron Activation (INAA). To evaluate the sources of anthropogenic contamination the enrichment factor (FE) and the geoacumulation index (IGeo) were calculated using NASC and Guarapiranga Park Soil as Reference Values. Results were compared to the concentration guideline values established by CCME (Canadian Council of Ministers of the Environment) environmental agency for As, Cr and Zn, and values in other published studies. Most points exceeded TEL values and, in some points, PEL values for these elements, indicating poor sediment quality in these reservoirs. In general terms, the elements As, Cr, Sb and Zn through EF and IGeo calculations present enrichment at all points analyzed, in both collection campaigns, except for the Rio Grande Reservoir points. The region where the reservoirs are located receive untreated sewage as well as pollution from urban occupation, industrial and mining activities, making it difficult to accurately identify the pollution sources. This study found higher concentrations of the elements analyzed in the Billings Reservoir, indicating a greater contamination level in relation to the other reservoirs. (author)

  14. Trace metal levels in sediments of Pearl Harbor (Hawaii)

    International Nuclear Information System (INIS)

    Ashwood, T.L.; Olsen, C.R.; Larsen, I.L.; Tamura, T.

    1986-09-01

    This study was conducted to measure the distribution of lead and other trace metals in the sediments of Pearl Harbon (Hawaii) to determine whether paint chips from vessels of the US Navy's Inactive Fleet have affected the environmental quality of Middle Loch. Sediment cores (ranging from 0.5 to 3.0 m long) were collected from Middle Loch near the Naval Inactive Ships Maintenance Facility and in an area of West Loch that is relatively isolated and unaffected by naval operations. Concentrations of copper, lead, and zinc averaged 180 μg/g, 49 μg/g, and 272 μg/g, respectively, in recent Middle Loch sediments. These concentrations are significantly higher than those in either historical Middle Loch sediments or recent West Loch sediments. However, except for lead, the concentrations in recent Middle Loch sediments are similar to those of older Middle Loch sediments, which indicates that the increase in trace metal contamination began before the onset of Inactive Fleet operations (about 1946). Increased trace metal levels in recent Middle Loch sediments might be expected to result from two potential sources: (1) sewage discharges and (2) paint from inactive vessels. Since paint contains elevated levels of lead and zinc but little copper, the elevated copper levels in Middle Loch sediments tend to implicate sewage as the source of trace metal contamination. Moreover, the lead:zinc ratio of recent Middle Loch sediments (0.18:1) is a factor of 10 lower than that measured in paint (2.1:1), and the Middle Loch lead:zinc ratio is not significantly greater than that measured in recent West Loch sediments (0.21:1). Hence, we suggest that sewage rather than paint is the major source of trace metal contamination of Middle Loch. This is consistent with the findings of a previous study by US navy personnel

  15. Highly concentrating Fresnel lenses

    International Nuclear Information System (INIS)

    Kritchman, E.M.; Friesem, A.A.; Yekutieli, G.

    1979-01-01

    A new type of concave Fresnel lens capable of concentrating solar radiation very near the ultimate concentration limit is considered. The differential equations that describe the lens are solved to provide computed solutions which are then checked by ray tracing techniques. The performance (efficiency and concentration) of the lens is investigated and compared to that of a flat Fresnel lens, showing that the new lens is preferable for concentrating solar radiation. (author)

  16. Trace conditioning in insects – Keep the trace!

    Directory of Open Access Journals (Sweden)

    Kristina V Dylla

    2013-08-01

    Full Text Available Trace conditioning is a form of associative learning that can be induced by presenting a conditioned stimulus (CS and an unconditioned stimulus (US following each other, but separated by a temporal gap. This gap distinguishes trace conditioning from classical delay conditioning, where the CS and US overlap. To bridge the temporal gap between both stimuli and to form an association between CS and US in trace conditioning, the brain must keep a neural representation of the CS after its termination – a stimulus trace. Behavioral and physiological studies on trace and delay conditioning revealed similarities between the two forms of learning, like similar memory decay and similar odor identity perception in invertebrates. On the other hand differences were reported also, like the requirement of distinct brain structures in vertebrates or disparities in molecular mechanisms in both vertebrates and invertebrates. For example, in commonly used vertebrate conditioning paradigms the hippocampus is necessary for trace but not for delay conditioning, and Drosophila delay conditioning requires the Rutabaga adenylyl cyclase, which is dispensable in trace conditioning. It is still unknown how the brain encodes CS traces and how they are associated with a US in trace conditioning. Insects serve as powerful models to address the mechanisms underlying trace conditioning, due to their simple brain anatomy, behavioral accessibility and established methods of genetic interference. In this review we summarize the recent progress in insect trace conditioning on the behavioral and physiological level and emphasize similarities and differences compared to delay conditioning. Moreover, we examine proposed molecular and computational models and reassess different experimental approaches used for trace conditioning.

  17. Trophodynamics of mercury and other trace elements in a pelagic food chain from the Baltic Sea

    International Nuclear Information System (INIS)

    Nfon, Erick; Cousins, Ian T.; Jaervinen, Olli; Mukherjee, Arun B.; Verta, Matti; Broman, Dag

    2009-01-01

    Mercury (Hg) and 13 other trace elements (Al, Ti, V, Cr, Fe, Mn, Co, Ni, Cu, Zn, As, Cd, and Pb) were measured in phytoplankton, zooplankton, mysis and herring in order to examine the trophodynamics in a well-studied pelagic food chain in the Baltic Sea. The fractionation of nitrogen isotopes (δ 15 N) was used to evaluate food web structure and to estimate the extent of trophic biomagnification of the various trace elements. Trophic magnification factors (TMFs) for each trace element were determined from the slope of the regression between trace element concentrations and δ 15 N. Calculated TMFs showed fundamental differences in the trophodynamics of the trace elements in the pelagic food chain studied. Concentrations of Al, Fe, Ni, Zn, Pb and Cd showed statistically significant decreases (TMF 1) in concentration with trophic level i.e. Hg biomagnifies in this Baltic food chain. The estimated TMF for Hg in this food chain was comparable to TMFs observed elsewhere for diverse food chains and locations.

  18. Mechanical tolerances study through simulations and experimental characterization for a 1000X micro-concentrator CPV module

    Science.gov (United States)

    Ritou, Arnaud; Voarino, Philippe; Goubault, Baptiste; David, Nadine; Bernardis, Sarah; Raccurt, Olivier; Baudrit, Mathieu

    2017-09-01

    Existing CPV technology markets are not compliant with a standard configuration. Concentrations vary from several suns to more than 1000 suns and the optical technology used could be very different. Nowadays, the market trends are moving toward more and more compact optical systems in order to exploit the Light Emitting Diode (LED) like approach. The aim is to increase the optical efficiency by using an ultra-short focal distance and to improve thermal management. Moreover the efficiency to weight ratio is increasing and the solar cell size becomes sub-millimetric. With these conditions, more stringent mechanical tolerances are essential to ensure an optimum optical alignment between cells and optics. A new process of micro-concentrator manufacturing is developed in this work. This process enables manufacturing and auto-alignment of Primary Optical Elements (POE) with Secondary Optical Elements (SOE) and solar cells with respect to certain mechanical tolerances. A 1000X micro-concentrator is manufactured with 0.6 x 0.6 mm² triple-junction cells and molded silicone optics. Mechanical alignment defects are studied by ray-tracing simulations and a prototype is characterized with respect to its mechanical behavior. An efficiency of 33.4% is measured with a Cell-to-Module ratio of 77.8%.

  19. Sorption of trace cesium on 21 Hanford Site sediment types

    International Nuclear Information System (INIS)

    Routson, R.C.; Barney, G.S.; Smith, R.M.; Delegard, C.A.

    1980-03-01

    Sorption of trace cesium (Cs) was measured on 21 Hanford Site sediment types. A Box-Behnken statistical design was used to develop empirical-statistical equations predicting 137 Cs sorption as a function of the equilibrium concentrations of macroions Na + , K + , and Ca +2 in solution over the concentration ranges of 3.0 to 0.001M, 0.2 to 0.002M, and 0.2 to 0.002M, respectively. These equations are required to estimate trace Cs transport from Hanford ground disposal sites. Average Cs sorption equations for the 21 sediments will be presented and discussed

  20. Decrease of concentration and colloidal fraction of organic carbon and trace elements in response to the anomalously hot summer 2010 in a humic boreal lake

    International Nuclear Information System (INIS)

    Shirokova, L.S.; Pokrovsky, O.S.; Moreva, O.Yu.; Chupakov, A.V.; Zabelina, S.A.; Klimov, S.I.; Shorina, N.V.; Vorobieva, T.Ya.

    2013-01-01

    The colloidal distribution and size fractionation of organic carbon (OC), major elements and trace elements (TE) were studied in a seasonally stratified, organic-rich boreal lake, Lake Svyatoe, located in the European subarctic zone (NW Russia, Arkhangelsk region). This study took place over the course of 4 years in both winter and summer periods using an in situ dialysis technique (1 kDa, 10 kDa and 50 kDa) and traditional frontal filtration and ultrafiltration (5, 0.22 and 0.025 μm). We observed a systematic difference in dissolved elements and colloidal fractions between summer and winter periods with the highest proportion of organic and organo-ferric colloids (1 kDa–0.22 μm) observed during winter periods. The anomalously hot summer of 2010 in European Russia produced surface water temperatures of approximately 30 °C, which were 10° above the usual summer temperatures and brought about crucial changes in element speciation and size fractionation. In August 2010, the concentration of dissolved organic carbon (DOC) decreased by more than 30% compared to normal period, while the relative proportion of organic colloids decreased from 70–80% to only 20–30% over the full depth of the water column. Similarly, the proportion of colloidal Fe decreased from 90–98% in most summers and winters to approximately 60–70% in August 2010. During this hot summer, measurable and significant (> 30% compared to other periods) decreases in the colloidal fractions of Ca, Mg, Sr, Ba, Al, Ti, Ni, As, V, Co, Y, all rare earth elements (REEs), Zr, Hf, Th and U were also observed. In addition, dissolved ( 100 for Co), the second and third factors could have brought about the decrease of allochthonous DOC concentration as well as the concentration and proportion of organic and organo-mineral colloidal forms of non-essential low-soluble trace elements present in the form of organic colloids (Al, Y, Ti, Zr, Hf, Th, Pb, all REEs). It can be hypothesized that climate warming in

  1. Ultra-high temperature direct propulsion

    International Nuclear Information System (INIS)

    Araj, K.J.; Slovik, G.; Powell, J.R.; Ludewig, H.

    1987-01-01

    Potential advantages of ultra-high exhaust temperature (3000 K - 4000 K) direct propulsion nuclear rockets are explored. Modifications to the Particle Bed Reactor (PBR) to achieve these temperatures are described. Benefits of ultra-high temperature propulsion are discussed for two missions - orbit transfer (ΔV = 5546 m/s) and interplanetary exploration (ΔV = 20000 m/s). For such missions ultra-high temperatures appear to be worth the additional complexity. Thrust levels are reduced substantially for a given power level, due to the higher enthalpy caused by partial disassociation of the hydrogen propellant. Though technically challenging, it appears potentially feasible to achieve such ultra high temperatures using the PBR

  2. ULTRA-LIGHTWEIGHT CEMENT

    Energy Technology Data Exchange (ETDEWEB)

    Fred Sabins

    2001-10-23

    The objective of this project is to develop an improved ultra-lightweight cement using ultra-lightweight hollow glass spheres (ULHS). Work reported herein addresses tasks performed in the fourth quarter as well as the other three quarters of the past year. The subjects that were covered in previous reports and that are also discussed in this report include: Analysis of field laboratory data of active cement applications from three oil-well service companies; Preliminary findings from a literature review focusing on problems associated with ultra-lightweight cements; Summary of pertinent information from Russian ultra-lightweight cement literature review; and Comparison of compressive strengths of ULHS systems using ultrasonic and crush methods Results reported from the fourth quarter include laboratory testing of ULHS systems along with other lightweight cement systems--foamed and sodium silicate slurries. These comparison studies were completed for two different densities (10.0 and 11.5 lb/gal) and three different field application scenarios. Additional testing included the mechanical properties of ULHS systems and other lightweight systems. Studies were also performed to examine the effect that circulation by centrifugal pump during mixing has on breakage of ULHS.

  3. Insight on trace element detoxification in the Black-tailed Godwit (Limosa limosa) through genetic, enzymatic and metallothionein analyses

    Energy Technology Data Exchange (ETDEWEB)

    Lucia, Magali, E-mail: m.lucia33@laposte.net [Littoral, Environnement et Societes (LIENSs), UMR 7266 CNRS-Universite de La Rochelle, 2 rue Olympe de Gouges, 17000 La Rochelle (France); Bocher, Pierrick [Littoral, Environnement et Societes (LIENSs), UMR 7266 CNRS-Universite de La Rochelle, 2 rue Olympe de Gouges, 17000 La Rochelle (France); Cosson, Richard P. [Mer Molecules Sante (MMS), Universite de Nantes, EA 2663, 2 rue de la Houssiniere, BP 92208, 44322 Nantes Cedex 3 (France); Churlaud, Carine; Robin, Frederic; Bustamante, Paco [Littoral, Environnement et Societes (LIENSs), UMR 7266 CNRS-Universite de La Rochelle, 2 rue Olympe de Gouges, 17000 La Rochelle (France)

    2012-04-15

    Trace element concentrations (Ag, As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se, Zn) were investigated in the liver, kidneys, muscle and feathers of 31 black-tailed godwits (Limosa limosa) accidentally killed during catches by mist net in the Pertuis Charentais, Atlantic coast of France. Analyses of carbon and nitrogen stable isotope ratios were carried out in liver, muscle and feathers in order to elucidate dietary patterns and to determine whether differences in diet explained the variation in elemental uptake. This study also aimed to have a preliminary assessment of sub-lethal effects triggered by trace elements through the investigation of gene expressions by quantitative real-time PCR, antioxidant enzyme activities (catalase, superoxide dismutase, glutathione peroxidase), and metallothionein (MT) levels. The results showed that Cr and Ni concentrations in tissues of adults were lower than in juveniles in part because adults may have eliminated these trace elements through moulting. Except for Cd and Ni, trace element concentrations were negatively correlated to the body mass of godwits. Ag, As, Hg and Se concentrations were positively linked with the trophic position of birds. The diet could be considered as a fundamental route of exposure for these elements demonstrating therefore the qualitative linkage between dietary habits of godwits and their contaminant concentrations. Our results strongly suggest that even though trace element concentrations were mostly below toxicity threshold level, the elevated concentrations of As, Ag, Cd, Cu, Fe and Se may however trigger sub-lethal effects. Trace elements appear to enhance expression of genes involved in oxidative stress defence, which indicates the production of reactive oxygen species. Moreover, birds with the highest concentrations appeared to have an increased mitochondrial metabolism suggesting that the fight against trace element toxicity requires additional energetic needs notably to produce detoxification

  4. Insight on trace element detoxification in the Black-tailed Godwit (Limosa limosa) through genetic, enzymatic and metallothionein analyses

    International Nuclear Information System (INIS)

    Lucia, Magali; Bocher, Pierrick; Cosson, Richard P.; Churlaud, Carine; Robin, Frédéric; Bustamante, Paco

    2012-01-01

    Trace element concentrations (Ag, As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se, Zn) were investigated in the liver, kidneys, muscle and feathers of 31 black-tailed godwits (Limosa limosa) accidentally killed during catches by mist net in the Pertuis Charentais, Atlantic coast of France. Analyses of carbon and nitrogen stable isotope ratios were carried out in liver, muscle and feathers in order to elucidate dietary patterns and to determine whether differences in diet explained the variation in elemental uptake. This study also aimed to have a preliminary assessment of sub-lethal effects triggered by trace elements through the investigation of gene expressions by quantitative real-time PCR, antioxidant enzyme activities (catalase, superoxide dismutase, glutathione peroxidase), and metallothionein (MT) levels. The results showed that Cr and Ni concentrations in tissues of adults were lower than in juveniles in part because adults may have eliminated these trace elements through moulting. Except for Cd and Ni, trace element concentrations were negatively correlated to the body mass of godwits. Ag, As, Hg and Se concentrations were positively linked with the trophic position of birds. The diet could be considered as a fundamental route of exposure for these elements demonstrating therefore the qualitative linkage between dietary habits of godwits and their contaminant concentrations. Our results strongly suggest that even though trace element concentrations were mostly below toxicity threshold level, the elevated concentrations of As, Ag, Cd, Cu, Fe and Se may however trigger sub-lethal effects. Trace elements appear to enhance expression of genes involved in oxidative stress defence, which indicates the production of reactive oxygen species. Moreover, birds with the highest concentrations appeared to have an increased mitochondrial metabolism suggesting that the fight against trace element toxicity requires additional energetic needs notably to produce detoxification

  5. Can liming change root anatomy, biomass allocation and trace element distribution among plant parts of Salix × smithiana in trace element-polluted soils?

    Science.gov (United States)

    Vondráčková, Stanislava; Tlustoš, Pavel; Száková, Jiřina

    2017-08-01

    Willows (Salix spp.) are considered to be effective for the phytoremediation of trace elements from contaminated soils, but their efficiency is limited in heavily polluted soils because of poor growth. Liming can be a desirable measure to decrease the plant availability of elements, resulting in improved plant development. Notably, large root area and maximum soil penetration are basic parameters that improve the efficiency of phytoremediation. The impact of soil chemical properties on willow root anatomy and the distribution of trace elements below-ground have rarely been studied. The effect of liming on root parameters, biomass allocation and trace element distribution in non-harvestable (coarse roots, fine roots, stumps) and harvestable plant parts (twigs and leaves) of Salix × smithiana was assessed at the end of a 4-year pot experiment with two trace element-polluted soils that differed in terms of soil pH. Stump biomass predominated in weakly acidic soil. In neutral soil, the majority of biomass was located in fine roots and stumps; the difference from other plant parts was minor. Trace elements were the most concentrated in fine roots. Translocation to above-ground biomass increased as follows: Pb roots roots). Lime application decreased the concentrations of mobile Cd and Zn and related levels in plants, improved biomass production and root parameters and increased the removal of all trace elements in weakly acidic soil. None or minimum differences in the monitored parameters were recorded for dolomite treatments in both soils. The dose and source of liming had crucial effects on root anatomy. Growing willows in limed trace element-polluted soils is a suitable measure for combination of two remediation strategies, i.e. phytoextraction of Cd and Zn and assisted phytostabilization of As and Pb.

  6. The Little Penguin (Eudyptula minor) as an indicator of coastal trace metal pollution

    International Nuclear Information System (INIS)

    Finger, Annett; Lavers, Jennifer L.; Dann, Peter; Nugegoda, Dayanthi; Orbell, John D.; Robertson, Bruce; Scarpaci, Carol

    2015-01-01

    Monitoring trace metal and metalloid concentrations in marine animals is important for their conservation and could also reliably reflect pollution levels in their marine ecosystems. Concentrations vary across tissue types, with implications for reliable monitoring. We sampled blood and moulted feathers of the Little Penguin (Eudyptula minor) from three distinct colonies, which are subject to varying levels of anthropogenic impact. Non-essential trace metal and metalloid concentrations in Little Penguins were clearly linked to the level of industrialisation adjacent to the respective foraging zones. This trend was more distinct in blood than in moulted feathers, although we found a clear correlation between blood and feathers for mercury, lead and iron. This study represents the first reported examination of trace metals and metalloids in the blood of any penguin species and demonstrates that this high trophic feeder is an effective bioindicator of coastal pollution. - Highlights: • Trace metals measured in blood and feathers. • Arsenic, Mercury and Lead significantly higher at urban colony. • Correlations found between trace metals in feathers and blood. • Little Penguins are suitable bioindicators for coastal metal pollution. - This study confirms the suitability of the Little Penguin as a bioindicator of coastal metal pollution in coastal areas using non-destructive sampling methods

  7. Enrichment of trace elements in bottom ash from coal oxy-combustion: Effect of coal types

    CSIR Research Space (South Africa)

    Oboirien, BO

    2016-09-01

    Full Text Available In this study, the enrichment of trace elements in two coals under air and oxy-combustion conditions was studied. Twenty-one trace elements were evaluated. The two coal samples had a different concentration for the 21 trace elements, which was due...

  8. Trace element patterns in lichens following uranium mine closures

    International Nuclear Information System (INIS)

    Fahselt, D.; Wu, T.W.; Mott, B.

    1995-01-01

    Instrumental neutron activation analysis was used to determine trace elements in Cladina mitis (Sandst). Hale ampersand Culb. along transects extending from uranium mines at Elliot Lake and Agnew Lake in central Ontario, Canada. Levels of 11 elements were reported and the presence of uranium (U) was confirmed, although U concentrations were much less than in Cladina rangiferina 10 years earlier. Among the elements identified in lichen thalli was Th, which occurred in higher concentrations than U. All trace elements, including the two radionuclides, were found in deteriorating thallus parts as well as living podetia, and five of these seem to have originated as airborne particulates from minesites. In spite of mine closures, levels of Th and U remained higher near sources of ore dust and there was little relationship between radionuclide concentrations in thallus and substrate. 24 refs., 4 figs., 3 tabs

  9. A PIXE analysis for measuring the trace elements concentration in breast tissue of Iranian women

    International Nuclear Information System (INIS)

    Vatankhah, S.; Moosavi, K.; Salimi, J.; Geranpayeh, L.; Perovani, H.

    2003-01-01

    A powerful and improved technique, proton induced x-ray emission has been performed-yielding the elemental composition of 17 samples of surgically excised malignant and normal tumors of breast tissue. The samples without any further process as thick targets were put on cap ton foil backing. There are no homogenizing processes. The proton induced x-ray emission spectra analysis was performed using he non-linear least square fitting code AXIL and GUPIX. The samples are taken form patients in the wide range of age and are bombarded by 2.0 MeV energy proton beams produced by van de Graaff accelerator in vacuum. The quantitative comparison between two of tissue was evaluated by assessing the presence of calcium. Potassium, Iron, Copper and Zinc, as minor and trace elements. results in this study indicate that relative values of Cu/Zn, P/K and also Ca and S in being type were higher than those in those in malignant type, but the concentration of Fe and Zn in cancerous tissues was significantly higher than those for being type. Results suggest significant elevation of zinc in the pathological tissues. Cu/Zn ratio for both type of tissues are evaluated. The results show that this ratio in patients with breast cancer is significantly lower than the normal group. Selenium and arsenic was not obtained in any of 17 samples. Most of the tissues of benign kind (fibrocystic and fib ro adenoma)contain cadmium. Calcium concentration in normal tissues is significantly higher than tumorous tissues

  10. Trace element profiles of the sea anemone Anemonia viridis living nearby a natural CO2 vent

    Directory of Open Access Journals (Sweden)

    Rael Horwitz

    2014-09-01

    Full Text Available Ocean acidification (OA is not an isolated threat, but acts in concert with other impacts on ecosystems and species. Coastal marine invertebrates will have to face the synergistic interactions of OA with other global and local stressors. One local factor, common in coastal environments, is trace element contamination. CO2 vent sites are extensively studied in the context of OA and are often considered analogous to the oceans in the next few decades. The CO2 vent found at Levante Bay (Vulcano, NE Sicily, Italy also releases high concentrations of trace elements to its surrounding seawater, and is therefore a unique site to examine the effects of long-term exposure of nearby organisms to high pCO2 and trace element enrichment in situ. The sea anemone Anemonia viridis is prevalent next to the Vulcano vent and does not show signs of trace element poisoning/stress. The aim of our study was to compare A. viridis trace element profiles and compartmentalization between high pCO2 and control environments. Rather than examining whole anemone tissue, we analyzed two different body compartments—the pedal disc and the tentacles, and also examined the distribution of trace elements in the tentacles between the animal and the symbiotic algae. We found dramatic changes in trace element tissue concentrations between the high pCO2/high trace element and control sites, with strong accumulation of iron, lead, copper and cobalt, but decreased concentrations of cadmium, zinc and arsenic proximate to the vent. The pedal disc contained substantially more trace elements than the anemone’s tentacles, suggesting the pedal disc may serve as a detoxification/storage site for excess trace elements. Within the tentacles, the various trace elements displayed different partitioning patterns between animal tissue and algal symbionts. At both sites iron was found primarily in the algae, whereas cadmium, zinc and arsenic were primarily found in the animal tissue. Our data

  11. Trace element profiles of the sea anemone Anemonia viridis living nearby a natural CO2 vent.

    Science.gov (United States)

    Horwitz, Rael; Borell, Esther M; Fine, Maoz; Shaked, Yeala

    2014-01-01

    Ocean acidification (OA) is not an isolated threat, but acts in concert with other impacts on ecosystems and species. Coastal marine invertebrates will have to face the synergistic interactions of OA with other global and local stressors. One local factor, common in coastal environments, is trace element contamination. CO2 vent sites are extensively studied in the context of OA and are often considered analogous to the oceans in the next few decades. The CO2 vent found at Levante Bay (Vulcano, NE Sicily, Italy) also releases high concentrations of trace elements to its surrounding seawater, and is therefore a unique site to examine the effects of long-term exposure of nearby organisms to high pCO2 and trace element enrichment in situ. The sea anemone Anemonia viridis is prevalent next to the Vulcano vent and does not show signs of trace element poisoning/stress. The aim of our study was to compare A. viridis trace element profiles and compartmentalization between high pCO2 and control environments. Rather than examining whole anemone tissue, we analyzed two different body compartments-the pedal disc and the tentacles, and also examined the distribution of trace elements in the tentacles between the animal and the symbiotic algae. We found dramatic changes in trace element tissue concentrations between the high pCO2/high trace element and control sites, with strong accumulation of iron, lead, copper and cobalt, but decreased concentrations of cadmium, zinc and arsenic proximate to the vent. The pedal disc contained substantially more trace elements than the anemone's tentacles, suggesting the pedal disc may serve as a detoxification/storage site for excess trace elements. Within the tentacles, the various trace elements displayed different partitioning patterns between animal tissue and algal symbionts. At both sites iron was found primarily in the algae, whereas cadmium, zinc and arsenic were primarily found in the animal tissue. Our data suggests that A. viridis

  12. Consumers' conceptualization of ultra-processed foods.

    Science.gov (United States)

    Ares, Gastón; Vidal, Leticia; Allegue, Gimena; Giménez, Ana; Bandeira, Elisa; Moratorio, Ximena; Molina, Verónika; Curutchet, María Rosa

    2016-10-01

    Consumption of ultra-processed foods has been associated with low diet quality, obesity and other non-communicable diseases. This situation makes it necessary to develop educational campaigns to discourage consumers from substituting meals based on unprocessed or minimally processed foods by ultra-processed foods. In this context, the aim of the present work was to investigate how consumers conceptualize the term ultra-processed foods and to evaluate if the foods they perceive as ultra-processed are in concordance with the products included in the NOVA classification system. An online study was carried out with 2381 participants. They were asked to explain what they understood by ultra-processed foods and to list foods that can be considered ultra-processed. Responses were analysed using inductive coding. The great majority of the participants was able to provide an explanation of what ultra-processed foods are, which was similar to the definition described in the literature. Most of the participants described ultra-processed foods as highly processed products that usually contain additives and other artificial ingredients, stressing that they have low nutritional quality and are unhealthful. The most relevant products for consumers' conceptualization of the term were in agreement with the NOVA classification system and included processed meats, soft drinks, snacks, burgers, powdered and packaged soups and noodles. However, some of the participants perceived processed foods, culinary ingredients and even some minimally processed foods as ultra-processed. This suggests that in order to accurately convey their message, educational campaigns aimed at discouraging consumers from consuming ultra-processed foods should include a clear definition of the term and describe some of their specific characteristics, such as the type of ingredients included in their formulation and their nutritional composition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Concentration of heavy metals and trace elements in soils, waters and vegetables and assessment of health risk in the vicinity of a lignite-fired power plant

    Energy Technology Data Exchange (ETDEWEB)

    Noli, Fotini, E-mail: noli@chem.auth.gr; Tsamos, Panagiotis, E-mail: pktsamos@chem.auth.gr

    2016-09-01

    The pollution of agricultural soils, waters and products in the regions of lignite mines and fired power plants is of great importance. The concentration of As, Βa, Co, Cr, Sr, Sc, Th, U, Zn in soils and waters in the vicinity of a lignite-fired power plant in Northern Greece was determined using Instrumental Neutron Activation Analysis. The determination frequency was every three months during a period of one year in order to evaluate the seasonal impact of the pollution to the environment. Measurements were performed in three locations around the lignite mine as well as in one reference location at a certain distance from the mine. The results, which exhibited a slight seasonal variation, were compared, where possible, with literature values from other countries. The obtained data in most of the cases did not exceed the normal levels and indicated that the investigated area was only slightly contaminated. The concentration of heavy and trace metals was also measured in three common garden crops (tomato, cucumber and parsley) grown in this area. The calculated transfer factors (TF) from soil to vegetables and health risk quotients (HQ) do not denote a health risk. - Highlights: • Seasonal variation of heavy metals concentrations in soils and waters in a lignite mining area. • The elevated concentrations detected by NAA indicating minor contamination of the studied area. • Determination of minor and trace elements in vegetables. • The transfer factors and health risk quotients indicating a possible slight contamination in the area.

  14. Concentration of heavy metals and trace elements in soils, waters and vegetables and assessment of health risk in the vicinity of a lignite-fired power plant

    International Nuclear Information System (INIS)

    Noli, Fotini; Tsamos, Panagiotis

    2016-01-01

    The pollution of agricultural soils, waters and products in the regions of lignite mines and fired power plants is of great importance. The concentration of As, Βa, Co, Cr, Sr, Sc, Th, U, Zn in soils and waters in the vicinity of a lignite-fired power plant in Northern Greece was determined using Instrumental Neutron Activation Analysis. The determination frequency was every three months during a period of one year in order to evaluate the seasonal impact of the pollution to the environment. Measurements were performed in three locations around the lignite mine as well as in one reference location at a certain distance from the mine. The results, which exhibited a slight seasonal variation, were compared, where possible, with literature values from other countries. The obtained data in most of the cases did not exceed the normal levels and indicated that the investigated area was only slightly contaminated. The concentration of heavy and trace metals was also measured in three common garden crops (tomato, cucumber and parsley) grown in this area. The calculated transfer factors (TF) from soil to vegetables and health risk quotients (HQ) do not denote a health risk. - Highlights: • Seasonal variation of heavy metals concentrations in soils and waters in a lignite mining area. • The elevated concentrations detected by NAA indicating minor contamination of the studied area. • Determination of minor and trace elements in vegetables. • The transfer factors and health risk quotients indicating a possible slight contamination in the area.

  15. Role of primary substrate composition and concentration on attenuation of trace organic chemicals in managed aquifer recharge systems

    KAUST Repository

    Alidina, Mazahirali

    2014-11-01

    This study was undertaken to investigate the role of primary substrate composition and concentration on the attenuation of biodegradable emerging trace organic chemicals (TOrCs) in simulated managed aquifer recharge (MAR) systems. Four sets of soil columns were established in the laboratory, each receiving synthetic feed solutions comprising different ratios and concentrations of peptone-yeast and humic acid as the primary substrate to investigate the effect on removal of six TOrCs (atenolol, caffeine, diclofenac, gemfibrozil, primidone, and trimethoprim). Based on abiotic control experiments, adsorption was not identified as a significant attenuation mechanism for primidone, gemfibrozil and diclofenac. Caffeine, atenolol and trimethoprim displayed initial adsorptive losses, however, adsorption coefficients derived from batch tests confirmed that adsorption was limited and in the long-term experiment, biodegradation was the dominant attenuation process. Within a travel time of 16h, caffeine - an easily degradable compound exhibited removal exceeding 75% regardless of composition or concentration of the primary substrate. Primidone - a poorly degradable compound, showed no removal in any column regardless of the nature of the primary substrate. The composition and concentration of the primary substrate, however, had an effect on attenuation of moderately degradable TOrCs, such as atenolol, gemfibrozil and diclofenac, with the primary substrate composition seeming to have a larger impact on TOrC attenuation than its concentration. When the primary substrate consisted mainly of refractory substrate (humic acid), higher removal of the moderately degradable TOrCs was observed. The microbial communities in the columns receiving more refractory carbon, were noted to be more diverse and hence likely able to express a wider range of enzymes, which were more suitable for TOrC transformation. The effect of the primary substrate on microbial community composition, diversity

  16. Role of primary substrate composition and concentration on attenuation of trace organic chemicals in managed aquifer recharge systems.

    Science.gov (United States)

    Alidina, Mazahirali; Li, Dong; Ouf, Mohamed; Drewes, Jörg E

    2014-11-01

    This study was undertaken to investigate the role of primary substrate composition and concentration on the attenuation of biodegradable emerging trace organic chemicals (TOrCs) in simulated managed aquifer recharge (MAR) systems. Four sets of soil columns were established in the laboratory, each receiving synthetic feed solutions comprising different ratios and concentrations of peptone-yeast and humic acid as the primary substrate to investigate the effect on removal of six TOrCs (atenolol, caffeine, diclofenac, gemfibrozil, primidone, and trimethoprim). Based on abiotic control experiments, adsorption was not identified as a significant attenuation mechanism for primidone, gemfibrozil and diclofenac. Caffeine, atenolol and trimethoprim displayed initial adsorptive losses, however, adsorption coefficients derived from batch tests confirmed that adsorption was limited and in the long-term experiment, biodegradation was the dominant attenuation process. Within a travel time of 16 h, caffeine - an easily degradable compound exhibited removal exceeding 75% regardless of composition or concentration of the primary substrate. Primidone - a poorly degradable compound, showed no removal in any column regardless of the nature of the primary substrate. The composition and concentration of the primary substrate, however, had an effect on attenuation of moderately degradable TOrCs, such as atenolol, gemfibrozil and diclofenac, with the primary substrate composition seeming to have a larger impact on TOrC attenuation than its concentration. When the primary substrate consisted mainly of refractory substrate (humic acid), higher removal of the moderately degradable TOrCs was observed. The microbial communities in the columns receiving more refractory carbon, were noted to be more diverse and hence likely able to express a wider range of enzymes, which were more suitable for TOrC transformation. The effect of the primary substrate on microbial community composition, diversity

  17. Sex Difference in Draft-Legal Ultra-Distance Events - A Comparison between Ultra-Swimming and Ultra-Cycling.

    Science.gov (United States)

    Salihu, Lejla; Rüst, Christoph Alexander; Rosemann, Thomas; Knechtle, Beat

    2016-04-30

    Recent studies reported that the sex difference in performance in ultra-endurance sports such as swimming and cycling changed over the years. However, the aspect of drafting in draft-legal ultra-endurance races has not yet been investigated. This study investigates the sex difference in ultra-swimming and ultra-cycling draft-legal races where drafting - swimming or cycling behind other participants to save energy and have more power at the end of the race to overtake them, is allowed. The change in performance of the annual best and the annual three best in an ultra-endurance swimming race (16-km 'Faros Swim Marathon') over 38 years and in a 24-h ultra-cycling race ('World Cycling Race') over 13 years were compared and analysed with respect to sex difference. Furthermore, performances of the fastest female and male finishers ever were compared. In the swimming event, the sex difference of the annual best male and female decreased non-significantly (P = 0.262) from 5.3% (1976) to 1.0% (2013). The sex gap of speed in the annual three fastest swimmers decreased significantly (P = 0.043) from 5.9 ± 1.6% (1979) to 4.7 ± 3.1% (2013). In the cycling event, the difference in cycling speed between the annual best male and female decreased significantly (P = 0.026) from 33.31% (1999) to 10.89% (2011). The sex gap of speed in the annual three fastest decreased significantly (P = 0.001) from 32.9 ± 0.6% (1999) to 16.4 ± 5.9% (2011). The fastest male swimmer ever (swimming speed 5.3 km/h, race time: 03:01:55 h:min:s) was 1.5% faster than the fastest female swimmer (swimming speed 5.2 km/h, race time: 03:04:09 h:min:s). The three fastest male swimmers ever (mean 5.27 ± 0.13 km/h) were 4.4% faster than the three fastest female swimmers (mean 5.05 ± 0.20 km/h) (P swimming and cycling, the sex difference in the annual top and annual top three swimmers and cyclists decreased (i.e. non-linearly in swimmers and linearly in cyclists) over the years. The sex difference of the

  18. Kissinger method applied to the crystallization of glass-forming liquids: Regimes revealed by ultra-fast-heating calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Orava, J., E-mail: jo316@cam.ac.uk [Department of Materials Science & Metallurgy, University of Cambridge, 27 Charles Babbage Road, Cambridge CB3 0FS (United Kingdom); WPI-Advanced Institute for Materials Research (WPI-AIMR), Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Greer, A.L., E-mail: alg13@cam.ac.uk [Department of Materials Science & Metallurgy, University of Cambridge, 27 Charles Babbage Road, Cambridge CB3 0FS (United Kingdom); WPI-Advanced Institute for Materials Research (WPI-AIMR), Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan)

    2015-03-10

    Highlights: • Study of ultra-fast DSC applied to the crystallization of glass-forming liquids. • Numerical modeling of DSC traces at heating rates exceeding 10 orders of magnitude. • Identification of three regimes in Kissinger plots. • Elucidation of the effect of liquid fragility on the Kissinger method. • Modeling to study the regime in which crystal growth is thermodynamically limited. - Abstract: Numerical simulation of DSC traces is used to study the validity and limitations of the Kissinger method for determining the temperature dependence of the crystal-growth rate on continuous heating of glasses from the glass transition to the melting temperature. A particular interest is to use the wide range of heating rates accessible with ultra-fast DSC to study systems such as the chalcogenide Ge{sub 2}Sb{sub 2}Te{sub 5} for which fast crystallization is of practical interest in phase-change memory. Kissinger plots are found to show three regimes: (i) at low heating rates the plot is straight, (ii) at medium heating rates the plot is curved as expected from the liquid fragility, and (iii) at the highest heating rates the crystallization rate is thermodynamically limited, and the plot has curvature of the opposite sign. The relative importance of these regimes is identified for different glass-forming systems, considered in terms of the liquid fragility and the reduced glass-transition temperature. The extraction of quantitative information on fundamental crystallization kinetics from Kissinger plots is discussed.

  19. Kissinger method applied to the crystallization of glass-forming liquids: Regimes revealed by ultra-fast-heating calorimetry

    International Nuclear Information System (INIS)

    Orava, J.; Greer, A.L.

    2015-01-01

    Highlights: • Study of ultra-fast DSC applied to the crystallization of glass-forming liquids. • Numerical modeling of DSC traces at heating rates exceeding 10 orders of magnitude. • Identification of three regimes in Kissinger plots. • Elucidation of the effect of liquid fragility on the Kissinger method. • Modeling to study the regime in which crystal growth is thermodynamically limited. - Abstract: Numerical simulation of DSC traces is used to study the validity and limitations of the Kissinger method for determining the temperature dependence of the crystal-growth rate on continuous heating of glasses from the glass transition to the melting temperature. A particular interest is to use the wide range of heating rates accessible with ultra-fast DSC to study systems such as the chalcogenide Ge 2 Sb 2 Te 5 for which fast crystallization is of practical interest in phase-change memory. Kissinger plots are found to show three regimes: (i) at low heating rates the plot is straight, (ii) at medium heating rates the plot is curved as expected from the liquid fragility, and (iii) at the highest heating rates the crystallization rate is thermodynamically limited, and the plot has curvature of the opposite sign. The relative importance of these regimes is identified for different glass-forming systems, considered in terms of the liquid fragility and the reduced glass-transition temperature. The extraction of quantitative information on fundamental crystallization kinetics from Kissinger plots is discussed

  20. Newer trace elements measured by RNAA and AAS

    International Nuclear Information System (INIS)

    Gharib, A.G.

    2004-01-01

    Very recently, quite attention has been made on a few more trace elements in foodstuff as essential for animal and human health in certain ranges of concentration or intake. These traces are: aluminum, nickel, vanadium and tin. Al and Ni have been measured by atomic absorption spectroscopy (AAS), and the two latter ones measured by radiochemical neutron activation analysis (RNAA) in few references laboratories. Here, scandium was also analysed by instrumental neutron activation analysis (INAA). These measurements were made for the most of the Iranian diets and other participant countries' diets under the framework of a co-ordinated research project (CRP) of the IAEA during the period 1986-1994, but practically it took more years. Here in this work the daily dietary intakes of above mentioned trace elements are given and discussed while the results of 20 other nutritionally important trace elements appeared somewhere else. (author)

  1. Newer trace elements measured by RNNA and AAS

    International Nuclear Information System (INIS)

    Gharib, A.G.

    2004-01-01

    Very recently, special attention has been made on a few more trace elements in foodstuff as newer essential for animal and human health in certain ranges of concentration or intakes. These traces are namely: Aluminium, Nickel, Vanadium and Tin. A1 and Ni have been measured by Atomic Absorption Spectroscopy and two latter ones measured by Radiochemical Neutron Activation Analysis in some references laboratories. Here also scandium was analyzed by Instrumental Neutron Activation Analysis as well. These measurements were made for the most of Iranian diets and other participant countries' diets in frame of coordinated research project led by International Atomic Energy Agency period of 1986-1994, but practically it took more years. Here in this work the daily dietary intakes of aforesaid trace elements are given and discussed while the results of other 20 more nutritionally important trace elements were appeared somewhere else

  2. Trace element inhibition of phytase activity.

    Science.gov (United States)

    Santos, T; Connolly, C; Murphy, R

    2015-02-01

    Nowadays, 70 % of global monogastric feeds contains an exogenous phytase. Phytase supplementation has enabled a more efficient utilisation of phytate phosphorous (P) and reduction of P pollution. Trace minerals, such as iron (Fe), zinc (Zn), copper (Cu) and manganese (Mn) are essential for maintaining health and immunity as well as being involved in animal growth, production and reproduction. Exogenous sources of phytase and trace elements are regularly supplemented to monogastric diets and usually combined in a premix. However, the possibility for negative interaction between individual components within the premix is high and is often overlooked. Therefore, this initial study focused on assessing the potential in vitro interaction between inorganic and organic chelated sources of Fe, Zn, Cu and Mn with three commercially available phytase preparations. Additionally, this study has investigated if the degree of enzyme inhibition was dependent of the type of chelated sources. A highly significant relationship between phytase inhibition, trace mineral type as well as mineral source and concentration, p phytases for Fe and Zn, as well as for Cu with E. coli and Aspergillus niger phytases. Different chelate trace mineral sources demonstrated diversifying abilities to inhibit exogenous phytase activity.

  3. Trace elements in airborne particulates in South Africa

    International Nuclear Information System (INIS)

    Vleggaar, C.M.; Van As, D.; Watkins, J.L.; Mingay, D.W.; Wells, R.B.; Briggs, A.B.; Louw, C.W.

    1980-10-01

    Airborne particulate materials were monitored continously with calendar month sampling periods at 5 rural/background, 4 rural/developing/peri-urban, 6 urban and 7 industrial sites in South Africa. Concentrations of Al, Br, Ca, Cs, Cd, Cl, Co, Cr, Cu, Eu, Fe, K, Mg, Mn, Na, Ni, Pb, Rb, S, Sb, Sc, Se, Ti, V and Zn were determined with neutron activation analysis (NAA), atomic absorption spectroscopy (AAS) and particle-induced X-ray emission spectroscopy (PIXE) employed on a complementary basis. A review of sources of airborne trace elements is given. The monitoring program, sampling, sample-handling procedures, as well as the analytical methods used, are discussed in detail. The results of related studies, i.e. effects of filter materials; sampling rates and geometry; determinations of collection efficiencies; particle size ranges; effects of internal flux monitors on the precision and accuracy of NAA; trace impurities in blank materials; quality control by routine analysis of reference materials; comparison of results obtained by NAA, AAS, and PIXE analysis; are given, as is a review of air-pollution control and research policy in South Africa and of ambient air quality standards. Results are discussed in terms of general patterns in trace-element concentrations and enrichments, the general pattern in population centres, the variability of monthly concentrations, and in terms of long-term trends at background, rural, developing, peri-urban, urban and industrial sites. Cases of concern in respect of increasing concentrations are pointed out, as are the constantly high Pb levels at urban sites [af

  4. Potential sources of analytical bias and error in selected trace element data-quality analyses

    Science.gov (United States)

    Paul, Angela P.; Garbarino, John R.; Olsen, Lisa D.; Rosen, Michael R.; Mebane, Christopher A.; Struzeski, Tedmund M.

    2016-09-28

    Potential sources of analytical bias and error associated with laboratory analyses for selected trace elements where concentrations were greater in filtered samples than in paired unfiltered samples were evaluated by U.S. Geological Survey (USGS) Water Quality Specialists in collaboration with the USGS National Water Quality Laboratory (NWQL) and the Branch of Quality Systems (BQS).Causes for trace-element concentrations in filtered samples to exceed those in associated unfiltered samples have been attributed to variability in analytical measurements, analytical bias, sample contamination either in the field or laboratory, and (or) sample-matrix chemistry. These issues have not only been attributed to data generated by the USGS NWQL but have been observed in data generated by other laboratories. This study continues the evaluation of potential analytical bias and error resulting from matrix chemistry and instrument variability by evaluating the performance of seven selected trace elements in paired filtered and unfiltered surface-water and groundwater samples collected from 23 sampling sites of varying chemistries from six States, matrix spike recoveries, and standard reference materials.Filtered and unfiltered samples have been routinely analyzed on separate inductively coupled plasma-mass spectrometry instruments. Unfiltered samples are treated with hydrochloric acid (HCl) during an in-bottle digestion procedure; filtered samples are not routinely treated with HCl as part of the laboratory analytical procedure. To evaluate the influence of HCl on different sample matrices, an aliquot of the filtered samples was treated with HCl. The addition of HCl did little to differentiate the analytical results between filtered samples treated with HCl from those samples left untreated; however, there was a small, but noticeable, decrease in the number of instances where a particular trace-element concentration was greater in a filtered sample than in the associated

  5. Food systems transformations, ultra-processed food markets and the nutrition transition in Asia.

    Science.gov (United States)

    Baker, Phillip; Friel, Sharon

    2016-12-03

    Attracted by their high economic growth rates, young and growing populations, and increasingly open markets, transnational food and beverage corporations (TFBCs) are targeting Asian markets with vigour. Simultaneously the consumption of ultra-processed foods high in fat, salt and glycaemic load is increasing in the region. Evidence demonstrates that TFBCs can leverage their market power to shape food systems in ways that alter the availability, price, nutritional quality, desirability and ultimately consumption of such foods. This paper describes recent changes in Asian food systems driven by TFBCs in the retail, manufacturing and food service sectors and considers the implications for population nutrition. Market data for each sector was sourced from Euromonitor International for four lower-middle income, three upper-middle income and five high-income Asian countries. Descriptive statistics were used to describe trends in ultra-processed food consumption (2000-2013), packaged food retail distribution channels (1999-2013), 'market transnationalization' defined as the market share held by TFBCs relative to domestic firms (2004-2013), and 'market concentration' defined as the market share and thus market power held by the four leading firms (2004-2013) in each market. Ultra-processed food sales has increased rapidly in most middle-income countries. Carbonated soft drinks was the leading product category, in which Coca-Cola and PepsiCo had a regional oligopoly. Supermarkets, hypermarkets and convenience stores were becoming increasingly dominant as distribution channels for packaged foods throughout the region. Market concentration was increasing in the grocery retail sector in all countries. Food service sales are increasing in all countries led by McDonalds and Yum! Brands. However, in all three sectors TFBCs face strong competition from Asian firms. Overall, the findings suggest that market forces are likely to be significant but variable drivers of Asia

  6. Nuclear reaction analysis (NRA) for trace element detection

    Energy Technology Data Exchange (ETDEWEB)

    Doebeli, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Noll, K. [Bern Univ. (Switzerland)

    1997-09-01

    Ion beam induced nuclear reactions can be used to analyse trace element concentrations in materials. The method is especially suited for the detection of light contaminants in heavy matrices. (author) 3 figs., 2 refs.

  7. Distribution of trace species in power plant streams: A European perspective

    International Nuclear Information System (INIS)

    Meij, R.

    1994-01-01

    In the Netherlands only pulverized coal-fired dry bottom boilers are installed. The flue gases are cleaned by high-efficiency cold-side electrostatic precipitators (ESPs) and in all large coal-fired power plants by flue-gas desulfurization (FGD) installations of the lime(stone)/gypsum process. KEMA has performed a large research program on the fate of (trace) elements at coal-fired power plants. A great deal of attention has been paid to the concentrations and distribution of trace elements in coal, in ash and in the vapor phase in the flue gases. Sixteen balance studies of coal-fired power plants, where coal imported from various countries is fired, have been performed. With the information provided by these studies the enrichment factors for the trace elements in ash and the vaporization percentage of the minor and trace elements in the flue gases have been calculated. Using these enrichment factors and vaporization percentages combined with data on the concentration in the coal, the concentrations in the ash and in the vapor phase in the flue gases can be predicted. The emission into the air of trace elements occurs in the solid state (fly ash) and in the gaseous state. The emissions in the solid state are low due to the high degree of removal in the ESPs. The emissions in the gaseous phase are, relatively speaking, more important. In an FGD both emissions are further diminished. In the next section the behavior of elements in the boiler and ESP will be discussed. The influence of the electrostatic precipitators will be reviewed the section thereafter, followed by the fate of gaseous minor and trace elements. And finally the behavior of elements in the FGD will be treated in the last section

  8. Effects of elevated CO{sub 2} concentrations and fly ash amended soils on trace element accumulation and translocation among roots, stems and seeds of Glycine max (L.) Merr

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, J.H. [Multidisciplinary Institute of Plant Biology, Pollution and Bioindicator Section, Faculty of Physical and Natural Sciences, National University of Cordoba, Av. Velez Sarsfield 1611, X5016CGA Cordoba (Argentina); Klumpp, A.; Fangmeier, A. [Institute of Landscape and Plant Ecology (320), Plant Ecology and Ecotoxicology, Universitaet Hohenheim, August-von-Hartmann-Str. 3, 70599 Stuttgart (Germany); Pignata, M.L., E-mail: pignata@com.uncor.edu [Multidisciplinary Institute of Plant Biology, Pollution and Bioindicator Section, Faculty of Physical and Natural Sciences, National University of Cordoba, Av. Velez Sarsfield 1611, X5016CGA Cordoba (Argentina)

    2011-03-15

    The carbon dioxide (CO{sub 2}) levels of the global atmosphere and the emissions of heavy metals have risen in recent decades, and these increases are expected to produce an impact on crops and thereby affect yield and food safety. In this study, the effects of elevated CO{sub 2} and fly ash amended soils on trace element accumulation and translocation in the root, stem and seed compartments in soybean [Glycine max (L.) Merr.] were evaluated. Soybean plants grown in fly ash (FA) amended soil (0, 1, 10, 15, and 25% FA) at two CO{sub 2} regimes (400 and 600 ppm) in controlled environmental chambers were analyzed at the maturity stage for their trace element contents. The concentrations of Br, Co, Cu, Fe, Mn, Ni, Pb and Zn in roots, stems and seeds in soybeans were investigated and their potential risk to the health of consumers was estimated. The results showed that high levels of CO{sub 2} and lower concentrations of FA in soils were associated with an increase in biomass. For all the elements analyzed except Pb, their accumulation in soybean plants was higher at elevated CO{sub 2} than at ambient concentrations. In most treatments, the highest concentrations of Br, Co, Cu, Fe, Mn, and Pb were found in the roots, with a strong combined effect of elevated CO{sub 2} and 1% of FA amended soils on Pb accumulation (above maximum permitted levels) and translocation to seeds being observed. In relation to non-carcinogenic risks, target hazard quotients (TQHs) were significant in a Chinese individual for Mn, Fe and Pb. Also, the increased health risk due to the added effects of the trace elements studied was significant for Chinese consumers. According to these results, soybean plants grown for human consumption under future conditions of elevated CO{sub 2} and FA amended soils may represent a toxicological hazard. Therefore, more research should be carried out with respect to food consumption (plants and animals) under these conditions and their consequences for human

  9. Determination of toxic trace elements in body fluid reference samples

    International Nuclear Information System (INIS)

    Gills, T.E.; McClendon, L.T.; Maienthal, E.J.; Becker, D.A.; Durst, R.A.; LaFleur, P.D.

    1974-01-01

    The measurement of elemental concentration in body fluids has been widely used to give indication of exposures to certain toxic materials and/or a measure of body burden. To understand fully the toxicological effect of these trace elements on our physiological system, meaningful analytical data are required along with accurate standards or reference samples. The National Bureau of Standards has prepared for the National Institute for Occupational Safety and Health (NIOSH) a number of reference samples containing selected toxic trace elements in body fluids. The reference samples produced include mercury in urine at three concentration levels, five elements (Se, Cu, As, Ni and Cr) in freeze-dried urine at two levels, fluorine in freeze-dried urine at two levels and lead in blood at two concentration levels. These reference samples have been found to be extremely useful for the evaluation of field and laboratory analytical methods for the analysis of toxic trace elements. In particular the use of at least two calibration points (i.e., ''normal'' and ''elevated'' levels) for a given matrix provides a more positive calibration for most analytical techniques over the range of interest for occupational toxicological levels of exposure. (U.S.)

  10. Performance analysis of AlGaAs/GaAs tunnel junctions for ultra-high concentration photovoltaics

    International Nuclear Information System (INIS)

    García, I; Rey-Stolle, I; Algora, C

    2012-01-01

    An n ++ -GaAs/p ++ -AlGaAs tunnel junction with a peak current density of 10 100 A cm -2 is developed. This device is a tunnel junction for multijunction solar cells, grown lattice-matched on standard GaAs or Ge substrates, with the highest peak current density ever reported. The voltage drop for a current density equivalent to the operation of the multijunction solar cell up to 10 000 suns is below 5 mV. Trap-assisted tunnelling is proposed to be behind this performance, which cannot be justified by simple band-to-band tunnelling. The metal-organic vapour-phase epitaxy growth conditions, which are in the limits of the transport-limited regime, and the heavy tellurium doping levels are the proposed origins of the defects enabling trap-assisted tunnelling. The hypothesis of trap-assisted tunnelling is supported by the observed annealing behaviour of the tunnel junctions, which cannot be explained in terms of dopant diffusion or passivation. For the integration of these tunnel junctions into a triple-junction solar cell, AlGaAs barrier layers are introduced to suppress the formation of parasitic junctions, but this is found to significantly degrade the performance of the tunnel junctions. However, the annealed tunnel junctions with barrier layers still exhibit a peak current density higher than 2500 A cm -2 and a voltage drop at 10 000 suns of around 20 mV, which are excellent properties for tunnel junctions and mean they can serve as low-loss interconnections in multijunction solar cells working at ultra-high concentrations. (paper)

  11. The separation and determination of trace elements in iron ore

    International Nuclear Information System (INIS)

    Jones, E.A.

    1977-01-01

    The separation, concentration, and determination of trace elements in iron ores are described. After the sample has been dissolved, the iron is separated by liquid-liquid extraction with a liquid cation-exchanger, di-(2-ethylhexyl) phosphoric acid. The trace elements aluminium, cadmium, calcium, chromium, cobalt, copper, lead, magnesium, manganese, mercury, potassium, sodium, vanadium, and zinc are determined in the aqueous phase by atomic-absorption spectrophotometry

  12. Adsorption of trace metals to plastic resin pellets in the marine environment

    International Nuclear Information System (INIS)

    Holmes, Luke A.; Turner, Andrew; Thompson, Richard C.

    2012-01-01

    Plastic production pellets collected from beaches of south west England contain variable concentrations of trace metals (Cr, Co, Ni, Cu, Zn, Cd and Pb) that, in some cases, exceed concentrations reported for local estuarine sediments. The rates and mechanisms by which metals associate with virgin and beached polyethylene pellets were studied by adding a cocktail of 5 μg L −1 of trace metals to 10 g L −1 pellet suspensions in filtered seawater. Kinetic profiles were modelled using a pseudo-first-order equation and yielded response times of less than about 100 h and equilibrium partition coefficients of up to about 225 ml g −1 that were consistently higher for beached pellets than virgin pellets. Adsorption isotherms conformed to both the Langmuir and Freundlich equations and adsorption capacities were greater for beached pellets than for virgin pellets. Results suggest that plastics may represent an important vehicle for the transport of metals in the marine environment. - Highlights: ► Beached plastic production pellets contain considerable concentrations of trace metals. ► In laboratory experiments trace metals are shown to adsorb to both virgin and beached pellets. ► Metal adsorption is greater on aged pellets. ► Pellets may represent an important vehicle for metal transport in the marine environment. - Trace metals accumulate on plastic resin pellets in the marine environment through adsorption to the polymer and to chemical and biological attritions thereon.

  13. Enrichment and Bioavailability of Trace Elements in Soil in Vicinity of Railways in Japan.

    Science.gov (United States)

    Wang, Zhen; Watanabe, Izumi; Ozaki, Hirozaku; Zhang, Jianqiang

    2018-01-01

    This study focuses on the concentrations, distribution, pollution levels, and bioavailability of 12 trace elements in soils along 6 different railways in Japan. Three diesel powered railways and three electricity powered railways were chosen as target. Surface soils (railways for analysis. Digestion and extraction were performed before concentration and bioavailability analysis. Enrichment factor was applied to investigate contamination levels of selected elements. The mean concentrations of Cr, Co, Ni, Cu, Zn, Sn, and Pb in soil samples were higher than soil background value in Japan. Concentrations of trace elements in soils along different railway had different characteristics. Horizontal distribution of Cu, Zn, Cd, Sn, and Pb in soil samples showed obviously downtrend with distance along railways with high frequency. Concentrations of V, Mn, Fe, and Co were higher in soils along railways which pass through city center. According to principal component analysis and cluster analysis, concentrations of Cu, Zn, Sn, and Pb could be considered as the indicators of soil contamination level along electricity powered trains, whereas indicators along diesel powered trains were not clear. Enrichment factor analysis proved that operation of freight trains had impact on pollution level of Cr, Ni, and Cd. Bioavailability of Mn, Co, Zn, and Cd in soil along electricity-powered railways were higher, and bioavailability of Pb in railways located in countryside was lower. Thus, enrichment and bioavailability of trace elements can be indicators of railway-originated trace elements pollution in soil.

  14. Potential for acid emissions affecting trace element nutrition of livestock

    International Nuclear Information System (INIS)

    Smart, M.E.

    1992-01-01

    The role of sour gas emissions in trace element nutrition of livestock is discussed. Trace mineral nutrition and the evaluation of factors affecting it is very complex. Some trace minerals are antagonistic to each other, for example a dietary sulfur content of greater than 0.4% will suppress the availability of copper to ruminants. Dietary plants, age, pregnancy, and disease can all alter trace element concentrations. Species and breed of animal play a significant role in copper metabolism. Clinical signs associated with copper and zinc deficiency are discussed. These symptoms include lameness, lack of hair pigmentation, infertility, and scouring. Some of these symptoms may be caused by excess molybdenum. Clinical features associated with zinc deficiency include parakeratosis and inflammation of the skin. 4 figs., 1 tab

  15. Seasonally-resolved trace element concentrations in stalagmites from a shallow cave in New Mexico

    Science.gov (United States)

    Sekhon, N.; Banner, J.; Miller, N. R.; Carlson, P. E.; Breecker, D.

    2017-12-01

    High-resolution (sub-annual/seasonal) paleoclimate records extending beyond the instrumental period are required to test climate models and better understand how climate warming/cooling and wetting/drying are manifested seasonally. This is particularly the case for areas such as the southwest United States where precipitation and temperature seasonality dictate the regional climate. Study of a 20thcentury stalagmite (Carlson et al., in prep) documented (1) seasonal variation in trace element compositions of a stalagmite from a shallow, well-ventilated cave and (2) demonstrated the seasonal variation in stalagmite Mg to be in agreement with predicted temperature-dependent fractionation between water and calcite. The seasonal nature of variability was constrained by monitoring the cave on a monthly basis (Casteel and Banner, 2015; Carlson et al., in prep). Here we expand on using stalagmites from shallow, well-ventilated caves as archives of seasonally-resolved climate recorders by studying trace element variations in two coeval modern stalagmites (SBFC-1 and SBFC-2) cored from Sitting Bull Falls, southern New Mexico. Seasonal cycles will be confirmed by analyzing Mg, Ba, and Sr in in-situ calcite precipitated on artificial substrates as available (July, Sept., and Nov. 2017). The chronology is constrained by semi-automated peak counting and 14C bomb-peak. In addition, principal component analyses of trace element data identify two primary underlying modes of trace element variability for soil-derived elements (Cu, Zn, and Fe) and bedrock-derived elements (Mg, Sr, and Ba). We hypothesize that the soil-derived elements are transported by seasonal infiltration of organic colloids and the bedrock-derived elements are ­­controlled by variability in cave air temperature, drip water, and calcite growth rate. The two modes of variability will be calibrated against instrumental data over the 20th century. When complete, these new seasonally resolved proxy records will

  16. Trace element and stable isotope analysis of fourteen species of marine invertebrates from the Bay of Fundy, Canada.

    Science.gov (United States)

    English, Matthew D; Robertson, Gregory J; Mallory, Mark L

    2015-12-15

    The Bay of Fundy, Canada, is a macrotidal bay with a highly productive intertidal zone, hosting a large abundance and diversity of marine invertebrates. We analysed trace element concentrations and stable isotopic values of δ(15)N and δ(13)C in 14 species of benthic marine invertebrates from the Bay of Fundy's intertidal zone to investigate bioaccumulation or biodilution of trace elements in the lower level of this marine food web. Barnacles (Balanus balanus) consistently had significantly greater concentrations of trace elements compared to the other species studied, but otherwise we found low concentrations of non-essential trace elements. In the range of trophic levels that we studied, we found limited evidence of bioaccumulation or biodilution of trace elements across species, likely due to the species examined occupying similar trophic levels in different food chains. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Radionuclides and trace metals in eastern Mediterranean Sea algae

    International Nuclear Information System (INIS)

    Al-Masri, M.S.; Mamish, S.; Budier, Y.

    2003-01-01

    Three types of sea alga distributed along the Syrian coast have been collected and analyzed for radioactivity and trace elements. Results have shown that 137 Cs concentrations in all the analyzed sample were relatively low (less than 1.2 Bq kg -1 dry weight) while the levels of naturally occurring radionuclides, such as 210 Po and 210 Pb, were found to be high in most samples; the highest observed value (27.43 Bq kg -1 dry weight) for 210 Po being in the red Jania longifurca alga. In addition, most brown alga species were also found to accumulate 210 Po, which indicates their selectivity to this isotope. On the other hand, brown alga (Cystoseira and Sargassum Vulgare) have shown a clear selectivity for some trace metals such as Cr, As, Cu and Co, this selectivity may encourage their use as biomonitor for pollution by trace metals. Moreover, the red alga species were found to contain the highest levels of Mg while the brown alga species were found to concentrate Fe, Mn, Na and K and nonmetals such as Cl, I and Br

  18. The Little Penguin (Eudyptula minor) as an indicator of coastal trace metal pollution.

    Science.gov (United States)

    Finger, Annett; Lavers, Jennifer L; Dann, Peter; Nugegoda, Dayanthi; Orbell, John D; Robertson, Bruce; Scarpaci, Carol

    2015-10-01

    Monitoring trace metal and metalloid concentrations in marine animals is important for their conservation and could also reliably reflect pollution levels in their marine ecosystems. Concentrations vary across tissue types, with implications for reliable monitoring. We sampled blood and moulted feathers of the Little Penguin (Eudyptula minor) from three distinct colonies, which are subject to varying levels of anthropogenic impact. Non-essential trace metal and metalloid concentrations in Little Penguins were clearly linked to the level of industrialisation adjacent to the respective foraging zones. This trend was more distinct in blood than in moulted feathers, although we found a clear correlation between blood and feathers for mercury, lead and iron. This study represents the first reported examination of trace metals and metalloids in the blood of any penguin species and demonstrates that this high trophic feeder is an effective bioindicator of coastal pollution. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Distribution of trace elements in whole blood of Syrian lymphomas patients using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Bakir, M. A.; Serhil, A.; Mohammad, A.; Habil, K.

    2013-12-01

    In recent years, there had been much interest in the concentrations of trace metals occurring in human and animal tissues and in the manner in which these concentrations may alter in malignant and other diseases. Neutron activation analysis is consider one of several methods that have been described for the determination of trace elements in biological materials. This method possesses the sensitivity and specificity necessary for the estimation at the concentrations existing naturally in most tissues, particularly when only small samples are available for analysis. The purpose of this study was to compare blood concentrations of trace elements Co, Cr, Fe, Rb, Sc, Se, Th, and Zn of lymphomas Syrian patients with those of healthy volunteers. Also, determine the relationships between trace elements concentration and the histological type of lymphomas. The blood samples were collected from 39 healthy volunteers and 49 patients with histologically confirmed lymphomas (29 Hodgkin's HL and 20 non-Hodgkin's lymphomas NHL), and analyzed to obtain the concentration of the trace elements in blood. Then, comparison between the healthy volunteers and lymphomas patients (both HL and NHL) was made to elucidate differences of the concentration distributions of the elements in blood. However, statistical analysis using Student's t test revealed significantly high concentrations of Co, Cr, Sc, and Th in lymphoma patients. Whereas Fe and Rb were found significantly decreased in lymphomas patient comparing to control group. Increasing or decreasing concentrations of Se and Zn in lymphoma patients was found not significant. Comparison between the healthy volunteers and non-Hodgkin's lymphomas patients reveled that Co, Cr, Sc, and Th were significantly elevated whereas, Rb only one trace element was decreased and all change in concentrations (elevating or decreasing) of Se and Zn were not significant. Comparison between the healthy volunteers and Hodgkin

  20. Measurement of total and free docetaxel concentration in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Rigo-Bonnin, Raül; Cobo-Sacristán, Sara; Gonzalo-Diego, Núria; Colom, Helena; Muñoz-Sánchez, Carmen; Urruticoechea, Ander; Falo, Catalina; Alía, Pedro

    2016-01-05

    Docetaxel is a semi-synthetic taxane with cytotoxic anti-neoplastic activity and, currently used as anticancer agent in several types of cancer. Docetaxel is highly bound to plasma proteins, and this significantly determines its clearance and activity. Therefore, measurement of free docetaxel in plasma is pharmacologically important when pharmacokinetics is investigated. We developed and validated chromatographic methods by ultra-performance liquid chromatography-tandem mass spectrometry to measure total and free docetaxel concentration in human plasma. The final validated methods involved liquid-liquid extraction followed by dryness under nitrogen evaporation. To measure free docetaxel concentration, sample preparation was preceded by ultrafiltration. Chromatographic separation was achieved using an Acquity(®) UPLC(®) BEH™ (2.1×100 mm id, 1.7 μm) reverse-phase C18 column at a flow rate of 0.4 mL/min, using isocratic elution mode containing ammonium acetate/formic acid in water/methanol (30:70 v/v) as mobile phase. Docetaxel and its internal standard (paclitaxel) were detected by electrospray ionization mass spectrometry in positive ion multiple reaction monitoring mode using mass-to-charge (m/z) transitions of 808.3→527.0 (quantifier) and 808.3→509.0 (qualifier); and 854.3→569.0 (quantifier) and 854,3→509,0 (qualifier), respectively. The run time per sample was 3.5 min. The limits of quantification were 1,95 and 0.42 μg/L and linearity was observed between 1.95 and 1000 and 0.42-100 μg/L for total and free docetaxel, respectively. Coefficients of variation and absolute relative biases were less than 13.8% and 10.0%. Recovery values were greater than 79.4%. Evaluation of the matrix effect showed ion suppression and no carry-over was observed. The validated methods could be useful for both therapeutic drug monitoring and pharmacokinetic studies. They could be applied to daily clinical laboratory practice to measure the concentration of total and free

  1. Trace Elements in Marine Sediment and Organisms in the Gulf of Thailand

    Science.gov (United States)

    Worakhunpiset, Suwalee

    2018-01-01

    This review summarizes the findings from studies of trace element levels in marine sediment and organisms in the Gulf of Thailand. Spatial and temporal variations in trace element concentrations were observed. Although trace element contamination levels were low, the increased urbanization and agricultural and industrial activities may adversely affect ecosystems and human health. The periodic monitoring of marine environments is recommended in order to minimize human health risks from the consumption of contaminated marine organisms. PMID:29677146

  2. Effects of salinity on trace elements in otoliths of Masu salmon

    International Nuclear Information System (INIS)

    Nagata, Yoshihisa; Arai, Nobuaki; Sakamoto, Wataru; Tago, Yasuhiko; Yoshida, Koji

    1997-01-01

    PIXE was adopted for analysis of trace elements in otoliths of Masu salmon Oncorhynchus masou masou to examine relationship between trace elements and environmental salinity. The otoliths were removed from salmon juveniles reared in four values of salinity and wild ones. The otolith Sr concentrations of reared individuals are positively related to salinity and there is significant difference between freshwater and seawater. The otoliths of smolts contain more Sr than those of parrs. It seems that the Sr concentrations in otoliths of Masu salmon reflect salinity where they had stayed and show the migration pattern. (author)

  3. Trace gas absorption spectroscopy using laser difference-frequency spectrometer for environmental application

    Science.gov (United States)

    Chen, W.; Cazier, F.; Boucher, D.; Tittel, F. K.; Davies, P. B.

    2001-01-01

    A widely tunable infrared spectrometer based on difference frequency generation (DFG) has been developed for organic trace gas detection by laser absorption spectroscopy. On-line measurements of concentration of various hydrocarbons, such as acetylene, benzene, and ethylene, were investigated using high-resolution DFG trace gas spectroscopy for highly sensitive detection.

  4. Geochemical and isotopic determination of deep groundwater contributions and salinity to the shallow groundwater and surface water systems, Mesilla Basin, New Mexico, Texas, and Mexico

    Science.gov (United States)

    Robertson, A.; Carroll, K. C.; Kubicki, C.; Purtshert, R.

    2017-12-01

    The Mesilla Basin/Conejos-Médanos aquifer system, extending from southern New Mexico to Chihuahua, Mexico, is a priority transboundary aquifer under the 2006 United States­-Mexico Transboundary Aquifer Assessment Act. Declining water levels, deteriorating water quality, and increasing groundwater use by municipal, industrial, and agricultural users on both sides of the international border raise concerns about long-term aquifer sustainability. Relative contributions of present-day and "paleo" recharge to sustainable fresh groundwater yields has not been determined and evidence suggests that a large source of salinity at the distal end of the Mesilla Basin is saline discharge from deep groundwater flow. The magnitude and distribution of those deep saline flow paths are not determined. The contribution of deep groundwater to discharge and salinity in the shallow groundwater and surface water of the Mesilla Basin will be determined by collecting discrete groundwater samples and analyzing for aqueous geochemical and isotopic tracers, as well as the radioisotopes of argon and krypton. Analytes include major ions, trace elements, the stable isotopes of water, strontium and boron isotopes, uranium isotopes, the carbon isotopes of dissolved inorganic carbon, noble gas concentrations and helium isotope ratios. Dissolved gases are extracted and captured from groundwater wells using membrane contactors in a process known as ultra-trace sampling. Gas samples are analyzed for radioisotope ratios of krypton by the ATTA method and argon by low-level counting. Effectiveness of the ultra-trace sampling device and method was evaluated by comparing results of tritium concentrations to the krypton-85 content. Good agreement between the analyses, especially in samples with undetectable tritium, indicates that the ultra-trace procedure is effective and confirms that introduction of atmospheric air has not occurred. The geochemistry data indicate a complex system of geochemical

  5. Inter-hemispheric gradient of atmospheric trace gases in the Pacific

    International Nuclear Information System (INIS)

    Lowe, D.; Manning, M.; Brailsford, G.; Bromley, T.; Moss, R.; Ferretti, D.

    1997-01-01

    Measurements of atmospheric trace gases show that the concentrations and isotopic compositions of these species can change dramatically across the intertropical convergence zone (ITCZ) separating the two hemispheres. Because the anthropogenic sources of virtually all trace gases are greater in the northern than in the southern hemisphere, concentrations of the species are lower in the southern hemisphere. Typically the concentration gradient is inversely proportional to the lifetime of the trace gas in the atmosphere. Hence understanding the transport across the ITCZ is crucial to determining the variation of important trace gases in the New Zealand region. Container ships are being used to collect large clean air samples on voyages across the Pacific on great circle routes between Auckland (New Zealand), Honolulu (Hawaii) and Los Angeles and Seattle on the US West coast. Measurements on these samples are being used to supplement extensive carbon isotope measurements of atmospheric methane made at fixed sites in the southern hemisphere: Baring Head (New Zealand), Suva (Fiji) and Scott Base (Antarctica) to provide information on the global methane cycle. The authors present the first results of high precision measurements of the stable isotopes of atmospheric carbon monoxide and methane in transects across the equator. These have been obtained using a Finnigan MAT 252 high precision isotope ratio mass spectrometer with a modified miniature inlet system and a stringent calibration protocol. Overall precision for δ 13 C in ambient methane and carbon monoxide in clean air approaches 0.02 per thousand which helps provide information on several subtle processes controlling the abundance of the trace gases in the atmosphere. The 13 C in methane and carbon dioxide data show remarkable seasonal variations across the intertropical convergence zone (ITCZ) and may be used to infer aspects of transport of gases to extra tropical regions in the southern hemisphere

  6. Distribution of uranium and some trace elements in groundwater of eastern delta, egypt

    International Nuclear Information System (INIS)

    Hamza, M.S.; Aly, A.I.M.; Swailem, F.M.; Elreedy, W.; Nada, A.

    1986-01-01

    The distribution pattern of uranium and some trace elements in groundwater of eastern Nile delta indicate general trend of increasing trace element concentration from west and south to North and east direction. This trend is most probably due to extensive leaching from the soil due to recharge from irrigation water. The geochemical correlation among trace elements was also investigated. Possible industrial pollution in bahtim area was detected.1 fig.,4 tab

  7. Trace metal speciation: Finally, correctly addressing trace metal issues

    International Nuclear Information System (INIS)

    Donard, O.F.X.

    2001-01-01

    The history of the development of trace metal speciation was discussed and the reasons behind the relatively slow widespread acceptance of its importance were presented. Partially, this was due to the lack of availability of commercial instrumentation and partly to the drive towards improving sensitivity in analytical chemistry which had focused attention on total concentration determinations. The sophistication and control of analytical instrumentation is now such that the spotlight must be turned onto the chemical species of an element present in a sample since this is what governs its behaviour in the biosphere. Indeed, several companies are currently considering the introduction of instrumentation specifically designed for metal species determination

  8. Development of Hplc Techniques for the Analysis of Trace Metal Species in the Primary Coolant of a Pressurised Water Reactor.

    Science.gov (United States)

    Barron, Keiron Robert Philip

    Available from UMI in association with The British Library. The need to monitor corrosion products in the primary circuit of a pressurised water reactor (PWR), at a concentration of 10pg ml^{-1} is discussed. A review of trace and ultra-trace metal analysis, relevant to the specific requirements imposed by primary coolant chemistry, indicated that high performance liquid chromatography (HPLC), coupled with preconcentration of sample was an ideal technique. A HPLC system was developed to determine trace metal species in simulated PWR primary coolant. In order to achieve the desired detection limit an on-line preconcentration system had to be developed. Separations were performed on Aminex A9 and Benson BC-X10 analytical columns. Detection was by post column reaction with Eriochrome Black T and Calmagite Linear calibrations of 2.5-100ng of cobalt (the main species of interest), were achieved using up to 200ml samples. The detection limit for a 200ml sample was 10pg ml^{-1}. In order to achieve the desired aim of on-line collection of species at 300^circ C, the use of inorganic ion-exchangers is essential. A novel application, utilising the attractive features of the inorganic ion-exchangers titanium dioxide, zirconium dioxide, zirconium arsenophosphate and pore controlled glass beads, was developed for the preconcentration of trace metal species at temperature and pressure. The performance of these exchangers, at ambient and 300^ circC was assessed by their inclusion in the developed analytical system and by the use of radioisotopes. The particular emphasis during the development has been upon accuracy, reproducibility of recovery, stability of reagents and system contamination, studied by the use of radioisotopes and response to post column reagents. This study in conjunction with work carried out at Winfrith, resulted in a monitoring system that could follow changes in coolant chemistry, on deposition and release of metal species in simulated PWR water loops. On

  9. Terrestrial sedimentary pyrites as a potential source of trace metal release to groundwater – A case study from the Emsland, Germany

    International Nuclear Information System (INIS)

    Houben, Georg J.; Sitnikova, Maria A.; Post, Vincent E.A.

    2017-01-01

    Pyrite is a common minor constituent of terrestrial freshwater sediments and a sink for trace elements. Different amounts and morphological types (framboids and euhedral crystals) of sedimentary pyrites were found in the heavy mineral fraction of cores obtained from several drillholes located in the Emsland region, NW Germany. Their trace element contents were investigated to assess their potential for groundwater contamination after oxidation, e.g. induced by dewatering or autotrophic denitrification. Nickel, arsenic and cadmium were found in significant concentrations in pyrite. Geochemical modeling showed that elevated trace metal concentrations in groundwater, potentially exceeding drinking water standards, should preferentially occur in a less than 1 m thick zone situated around the depth of the redoxcline, where nitrate is reduced by pyrite. This was confirmed by depth-specific groundwater sampling in the Emsland and by previously published studies. The absolute concentration of released trace metals depends on their content in the pyrite but also strongly on the nitrate load of groundwater. - Highlights: • Pyrite from heavy mineral fraction of aquifer sediment analyzed for trace metal content. • Pyrites contain significant concentration of trace metals, such as nickel, arsenic, cadmium. • Trace elements are released by autotrophic denitrification. • Reactive transport model predicts small zone of trace element accumulation. • Release of trace elements strongly dependent on nitrate content of groundwater.

  10. Concentrations of major and trace elements in polished rice and paddy soils collected in Aomori, Japan

    International Nuclear Information System (INIS)

    Tsukada, H.; Hasegawa, H.; Takeda, A.; Hisamatsu, S.

    2005-01-01

    Rice is a staple food in most Asian countries including Japan, and it is important to evaluate the intake of elements through polished rice ingestion in daily life. Rice grain samples and surface paddy soil samples were collected from 20 sites throughout Aomori Prefecture, Japan. Rice grains were threshed and then polished to 90% of the total weight of brown rice. The polished rice samples for the determination of the neutron activation analysis (NAA) were dried at 50 degree C and those of the inductively coupled plasma-mass spectrometer (ICP-MS) were ashed at a temperature below 450 degree C to avoid loss of alkali metals. The soil samples were dried at 50 degree C and were pulverized with an agate ball mill. The concentrations of As, Cl and I in the polished rice and As, Cl, I, Ti and Zr in the soils were determined by the NAA. The concentrations of 22 elements in the polished rice and 28 elements in the soils were determined by the ICP-MS. The mean concentrations of essential elements in the polished rice such as K, Mg, Cl, Ca, Zn, Mn, Fe, Cu and Mo were 720, 270, 160, 54, 16, 9.7, 2.3, 21 and 0.47 mg kg -1 dry weight, respectively, and the range of each element was within one order of magnitude. However, the ranges of most trace elements in the polished rice including Al, Ni, Ba, Cd, Pb, Cr, I, Ag and Cs were more than one order of magnitude. The mean concentrations of non-essential elements in the polished rice were as follows: Na, 11; Al, 3.9; Rb, 1.2; Ni, 0.11; As, Sr, Ba, Cd, V and Pb, 0.1-0.01; Cr, I, Co, Ag, Se and Cs, O.Ol-0.001 mg kg -1 dry weight. The concentration ranges of elements, except for I, in the paddy soils were within one order of magnitude. The mean concentrations of elements in the soils were as follows: Al, Fe, Ca and Na, 100000-10000; Mg, K and Ti, 10000-1000; Mn, Ba, Cl, Zr, Sr and Zn, 1000-100; V, Ce, Cr, Rb, Cu, Pb, Sc, La, As and Ni, 100-10; Co, Th, Cs, I, U, Mo and Se, 10-1; Sb, Cd and Ag, 1-0.1 mg kg -1 . The mean concentrations of

  11. Measurement of trace metals in vitiligo by atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Abdel-Hamid, Abdel-Aziz M.; Amin, N.E.; Mohy El-Din, Safaa M.

    1985-01-01

    Zn, Cu, Fe, Pb, Mn, Co, Ag, Ca, and Mg were estimated in hair, fingernails and epidermis of vitiligo patients by atomic absorption spectroscopy. There has been a significant reduction in the concentration of trace metals in the studied sites. It seems that any speculation on the role of trace elements in vitiligo would have to take into account the structural defect which underlies the absence of melanin

  12. Trace Element Compositions and Defect Structures of High-Purity Quartz from the Southern Ural Region, Russia

    Directory of Open Access Journals (Sweden)

    Jens Götze

    2017-10-01

    Full Text Available Quartz samples of different origin from 10 localities in the Southern Ural region, Russia have been investigated to characterize their trace element compositions and defect structures. The analytical combination of cathodoluminescence (CL microscopy and spectroscopy, electron paramagnetic resonance (EPR spectroscopy, and trace-element analysis by inductively coupled plasma mass spectrometry (ICP-MS revealed that almost all investigated quartz samples showed very low concentrations of trace elements (cumulative concentrations of <50 ppm with <30 ppm Al and <10 ppm Ti and low abundances of paramagnetic defects, defining them economically as “high-purity” quartz (HPQ suitable for high-tech applications. EPR and CL data confirmed the low abundances of substitutional Ti and Fe, and showed Al to be the only significant trace element structurally bound in the investigated quartz samples. CL microscopy revealed a heterogeneous distribution of luminescence centres (i.e., luminescence active trace elements such as Al as well as features of deformation and recrystallization. It is suggested that healing of defects due to deformation-related recrystallization and reorganization processes of the quartz lattice during retrograde metamorphism resulted in low concentrations of CL activator and other trace elements or vacancies, and thus are the main driving processes for the formation of HPQ deposits in the investigated area.

  13. Large-scale spatial and interspecies differences in trace elements and stable isotopes in marine wild fish from Chinese waters

    International Nuclear Information System (INIS)

    Zhang, Wei; Wang, Wen-Xiong

    2012-01-01

    Highlights: ► A large-scale study on trace element levels in marine wild fish from Chinese waters. ► Spatial variation found for Al, As, Cd, Cr, Fe, Ni, Pb, but not for Ag, Cu, Mo, Se and Zn. ► The Pearl River Estuary contained the highest concentrations of Al, Cr, Ni, and Pb. ► No biomagnification occurred for any of the trace elements studied in marine fish. ► No obvious health risk from the intake of trace elements through fish consumption. - Abstract: We conducted a large scale investigation of twelve trace element levels and stable isotopes (δ 13 C and δ 15 N) in twenty-nine marine wild fish species collected from Chinese coastal waters. Trace element levels varied significantly with species. Clear spatial variations were found for Al, As, Cd, Cr, Fe, Ni, and Pb, whereas Ag, Cu, Mo, Se and Zn did not show much spatial variation. The Pearl River Estuary contained the highest concentrations of Al, Cr, Ni, and Pb, whereas the most southern waters (Haikou) contained the lowest concentrations of Al, Fe, and Pb. There was no correlation between log-transformed trace elements concentrations and δ 15 N values or δ 13 C values, indicating no biomagnification among these trace elements. The calculated hazard quotients (HQ) of 10 elements were less than 1, thus there was no obvious health risk from the intake of trace elements through marine wild fish consumption.

  14. Modeling and validation of multiple joint reflections for ultra- narrow gap laser welding

    Energy Technology Data Exchange (ETDEWEB)

    Milewski, J.; Keel, G. [Los Alamos National Lab., NM (United States); Sklar, E. [Opticad Corp., Santa Fe, New Mexico (United States)

    1995-12-01

    The effects of multiple internal reflections within a laser weld joint as a function of joint geometry and processing conditions have been characterized. A computer model utilizing optical ray tracing is used to predict the reflective propagation of laser beam energy focused into the narrow gap of a metal joint for the purpose of predicting the location of melting and coalescence which form the weld. The model allows quantitative analysis of the effects of changes to joint geometry, laser design, materials and processing variables. This analysis method is proposed as a way to enhance process efficiency and design laser welds which display deep penetration and high depth to width aspect ratios, reduced occurrence of defects and enhanced melting. Of particular interest to laser welding is the enhancement of energy coupling to highly reflective materials. The weld joint is designed to act as an optical element which propagates and concentrates the laser energy deep within the joint to be welded. Experimentation has shown that it is possible to produce welds using multiple passes to achieve deep penetration and high depth to width aspect ratios without the use of filler material. The enhanced laser melting and welding of aluminum has been demonstrated. Optimization through modeling and experimental validation has resulted in the development of a laser welding process variant we refer to as Ultra-Narrow Gap Laser Welding.

  15. Amphibole trace elements as indicators of magmatic processes at Mount St. Helens

    Science.gov (United States)

    Hampel, T. R.; Rowe, M. C.; Kent, A.; Thornber, C. R.

    2011-12-01

    Amphibole has the capability of incorporating a wide variety of trace elements resulting from a range of magmatic processes. Prior studies have used trace elements such as Li and Cu in amphibole to investigate volatile mobility associated with magma ascent regarding the 2004-2008 eruption of Mount St. Helens (Rowe et al. 2008). In order to investigate magmatic processes associated with the 2004-2008 eruption of Mount St. Helens we have measured a range of fluid-mobile trace elements in conjunction with major element compositions of amphibole phenocrysts in dacite lava. Major elements and volatiles (Cl, F) were measured by electron microprobe analysis at Washington State University and trace elements (Li, Sc, Co, Cu, Zn, Sr, Y, Zr, Mo, Ag, Sn, Sb, Te, Ba, Ce, W, and Pb) were analyzed by laser ablation (LA)-ICP-MS at Oregon State University. Amphibole crystallization temperatures were calculated after Ridolfi et al. (2010). Core to rim transects were measured by electron microprobe to evaluate volatile concentrations and temperature profiles across individual phenocrysts. Core temperatures from 17 days and 226 days post eruption are consistently hotter than the rim temperatures 997 to 881 degrees C, respectively. Amphiboles from the end of the eruption (811 days post eruption) appear to be more complex, with phenocrysts having both increasing and decreasing temperatures toward the rims. The overall calculated temperature range of the amphiboles at the end of the eruption is 1022 to 919 degrees C. There is much diversity in the concentrations of Li and Cu within the phenocrysts in both the samples and throughout the eruption. Concentrations steadily increase in the beginning of the eruption then drop dramatically toward the middle, slowly increase toward the end eruption. Overall concentrations of Sr, Sb, Co, Sn, Mo, Ba, Ce, Sc, and Y do not change over the course of the eruption but do vary sample to sample. Preliminary data for Zn, Sb, Ag, and W suggest the

  16. Ultra-orthodox Jewish Women Go to Work

    Directory of Open Access Journals (Sweden)

    Foscarini, Giorgia

    2014-12-01

    Full Text Available In the last three decades the ultra-orthodox community in Israel has experienced great changes in its internal social functioning. More specifically, these developments were linked to the education of ultra-orthodox women. Through an accurate review of the existing literature and a series of in-depth interviews with Israeli scholars, rabbis, educators and women of the ultra-orthodox community in Jerusalem, it was found that the introduction of new vocational and academic training tracks in women's education, is gradually changing the internal social structure of the ultra-orthodox family and community. The main consequence is expressed in a renegotiation of gender roles within the ultra-orthodox community and in a subversion of the traditional patriarchal framework. As a result of their participation in the labor market and in higher education institutions, women are more and more exposed to the Israeli secular culture, introducing in the traditional and segregated ultra-orthodox community customs typically modern, narrowing the gap between the ultra-orthodox community and the mainstream Israeli society.

  17. Ion Imprinted Polymer for Preconcentration and Determination of Ultra-Trace Cadmium, Employing Flow Injection Analysis with Thermo Spray Flame Furnace Atomic Absorption Spectrometry.

    Science.gov (United States)

    do Lago, Ayla Campos; Marchioni, Camila; Mendes, Tássia Venga; Wisniewski, Célio; Fadini, Pedro Sergio; Luccas, Pedro Orival

    2016-11-01

    This work proposes a preconcentration method using an ion imprinted polymer (IIP) for determination of cadmium, in several samples, employing a mini-column filled with the polymer coupled into a flow injection analysis system with detection by thermospray flame furnace atomic absorption spectrometry (FIA-TS-FF-AAS). The polymer was synthesized via bulk using methacrylic acid and vinylimidazole as a functional monomer. For the FIA system initial assessment, the variables: pH, eluent concentration and buffer concentration were studied, employing a 23 full factorial design. To obtain the optimum values for each significant variable, a Doehlert matrix was employed. After the optimization conditions as: pH 5.8, eluent (HNO3) concentration of 0.48 mol L -1 and buffer concentration of 0.01 mol L -1 , were adopted. The proposed method showed a linear response in the range of 0.081-10.0 μg L -1 , limits detection and quantification of 0.024 and 0.081 μg L -1 , respectively; preconcentration factor of 165, consumptive index of 0.06 mL, concentration efficiency 132 min -1 , and frequency of readings equal to 26 readings h -1 The accuracy was checked by analysis of certified reference materials for trace metals and recovery tests. The obtained results were in agreement with 95% confidence level (t-test). The method was adequate to apply in samples of: jewelry (earrings) (2.38 ± 0.28 μg kg -1 ), black tea (1.09 ± 0.15 μg kg -1 ), green tea (3.85 ± 0.13 μg kg -1 ), cigarette tobacco (38.27 ± 0.22 μg kg -1 ), and hair (0.35 ± 0.02 μg kg -1 ). © The Author(s) 2016.

  18. Historical record of concentrations of atmospheric trace components deduced from a glacier in the Alps; Historische Entwicklung von atmosphaerischen Spurenstoffkonzentrationen rekonstruiert aus Firn und Eis alpiner Gletscher

    Energy Technology Data Exchange (ETDEWEB)

    Doescher, A. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1996-07-01

    A 109 m ice core from a high-alpine glacier (Colle Gnifetti, Monte Rosa massif, 4440 m a.s.l., Switzerland) was used to reconstruct the history of atmospheric trace components. Concentrations of the anions chloride, nitrate, sulfate and the cations sodium, ammonium, potassium, magnesium and calcium were measured with 2.5-5.0 cm resolution in the top 70 m of a 109 m long of the ice core. Dating of the ice core was performed using stratigraphic markers such as historically known Saharan dust events, the atomic bomb horizon and volcanic eruptions and supplemented with the {sup 210}Pb nuclear dating. The record covers the time period from about 1755-1981. The concentrations of nitrate and sulfate show an exponential increase from 1930 and 1870 until 1965, respectively. The factors of increase were 2.3{+-}0.3 and 5.8{+-}0.9, respectively. The chloride concentrations remained constant during this period. A good agreement between the concentrations of sulfate, which were corrected for the contribution of seasalt and mineral dust and the European SO{sub 2}-emissions was found for the last 100 years. The concentrations of sodium, potassium, magnesium and calcium did not show a trend. The concentrations of ammonium increased exponentially between 1870 and 1960 by a factor of 2.2{+-}0.4. The different sources of the trace components were identified using correlation analysis. Sodium and chloride originated from seasalt, magnesium and calcium from geologic erosion. For both, the industrial and pre-industrial period, the dominant source of ammonium and nitrate was conversion of the gaseous precursors NH{sub 3} and HNO{sub 3}. Sulfate concentrations in the industrial period originated from the anthropogenically emitted SO{sub 2}, whereas in the pre-industrial period the geologic source dominated. The Colle Gnifetti accumulates mainly summer snow, and therefore, several test drillings were performed to find a new site with higher accumulation rate. figs., 17 tabs., 50 refs.

  19. Concentrations of Trace Elements in Organic Fertilizers and Animal Manures and Feeds and Cadmium Contamination in Herbal Tea (Gynostemma pentaphyllum Makino).

    Science.gov (United States)

    Nookabkaew, Sumontha; Rangkadilok, Nuchanart; Prachoom, Norratouch; Satayavivad, Jutamaad

    2016-04-27

    Thailand is predominantly an agriculture-based country. Organic farming is enlisted as an important national agenda to promote food safety and international export. The present study aimed to determine the concentrations of trace elements in commercial organic fertilizers (fermented and nonfermented) composed of pig and cattle manures available in Thailand. Pig and cattle manures as well as animal feeds were also collected from either animal farms or markets. The results were compared to the literature data from other countries. Fermented fertilizer composed of pig manure contained higher concentrations of nitrogen (N) and phosphorus (P) than fertilizer composed of cattle manure. High concentrations of copper (Cu) and zinc (Zn) were also found in fertilizers and manures. Some organic fertilizers had high concentrations of arsenic (As), cadmium (Cd), and lead (Pb). The range of As concentration in these fertilizers was 0.50-24.4 mg/kg, whereas the ranges of Cd and Pb were 0.10-11.4 and 1.13-126 mg/kg, respectively. Moreover, pig manure contained As and Cd (15.7 and 4.59 mg/kg, respectively), higher than their levels in cattle manure (1.95 and 0.16 mg/kg, respectively). The use of pig manure as soil supplement also resulted in high Cd contamination in herbal tea (Gynostemma pentaphyllum Makino; GP). The Cd concentration in GP plants positively correlated with the Cd concentration in the soil. Therefore, the application of some organic fertilizers or animal manures to agricultural soil could increase some potentially toxic elements in soil, which may be absorbed by plants and, thus, increase the risk of contamination in agricultural products.

  20. High precision ray tracing in cylindrically symmetric electrostatics

    Energy Technology Data Exchange (ETDEWEB)

    Edwards Jr, David, E-mail: dej122842@gmail.com

    2015-11-15

    Highlights: • High precision ray tracing is formulated using power series techniques. • Ray tracing is possible for fields generated by solution to laplace's equation. • Spatial and temporal orders of 4–10 are included. • Precisions in test geometries of hemispherical deflector analyzer of ∼10{sup −20} have been obtained. • This solution offers a considerable extension to the ray tracing accuracy over the current state of art. - Abstract: With the recent availability of a high order FDM solution to the curved boundary value problem, it is now possible to determine potentials in such geometries with considerably greater accuracy than had been available with the FDM method. In order for the algorithms used in the accurate potential calculations to be useful in ray tracing, an integration of those algorithms needs to be placed into the ray trace process itself. The object of this paper is to incorporate these algorithms into a solution of the equations of motion of the ray and, having done this, to demonstrate its efficacy. The algorithm incorporation has been accomplished by using power series techniques and the solution constructed has been tested by tracing the medial ray through concentric sphere geometries. The testing has indicated that precisions of ray calculations of 10{sup −20} are now possible. This solution offers a considerable extension to the ray tracing accuracy over the current state of art.