WorldWideScience

Sample records for ultra narrow row

  1. Analysis of ultra-narrow ferromagnetic domain walls

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, Catherine; Paul, David

    2012-01-10

    New materials with high magnetic anisotropy will have domains separated by ultra-narrow ferromagnetic walls with widths on the order of a few unit cells, approaching the limit where the elastic continuum approximation often used in micromagnetic simulations is accurate. The limits of this approximation are explored, and the static and dynamic interactions with intrinsic crystalline defects and external driving elds are modeled. The results developed here will be important when considering the stability of ultra-high-density storage media.

  2. Narrow row and crossed lines associated with different plant densities of soybean

    Directory of Open Access Journals (Sweden)

    Alvadi Antonio Balbinot Junior

    2015-10-01

    Full Text Available The spatial arrangement of soybean plants affects the intraspecific competition for light, water and nutrients, which can change the biomass production, incidence of pests, diseases and weeds, plant lodging, and grain yield. This work aimed to evaluate the agronomic performance under different row spacing, plant densities and crossed rows. Two field experiments were carried out in Campo Mourão, Paraná State, Southern Brazil, using the randomized complete block experimental design, in a 3x3x2 factorial arrangement, with four replications. The treatments were formed by the combination of three row spacings (0.30, 0.45, and 0.60 m, three plant densities (300,000; 450,000; and 600,000 plants ha-1, and two row design (crossed or parallel rows. For all variables, interaction of the experimental factors was not significant. The row spacing of 0.45 m provided the highest grain yield in relation to 0.30 and 0.60 m. The density of 300,000 plants ha-1 showed higher yield of soybeans in late sowing. The crossed lines did not increase the productive performance in soybean.

  3. Movement of the distal carpal row during narrowing and widening of the carpal arch width.

    Science.gov (United States)

    Gabra, Joseph N; Domalain, Mathieu; Li, Zong-Ming

    2012-10-01

    Change in carpal arch width (CAW) is associated with wrist movement, carpal tunnel release, or therapeutic tunnel manipulation. This study investigated the angular rotations of the distal carpal joints as the CAW was adjusted. The CAW was narrowed and widened by 2 and 4 mm in seven cadaveric specimens while the bone positions were tracked by a marker-based motion capture system. The joints mainly pronated during CAW narrowing and supinated during widening. Ranges of motion about the pronation axis for the hamate-capitate (H-C), capitate-trapezoid (C-Td), and trapezoid-trapezium (Td-Tm) joints were 8.1 ± 2.3 deg, 5.3 ± 1.3 deg, and 5.5 ± 3.5 deg, respectively. Differences between the angular rotations of the joints were found at ΔCAW = -4 mm about the pronation and ulnar-deviation axes. For the pronation axis, angular rotations of the H-C joint were larger than that of the C-Td and Td-Tm joints. Statistical interactions among the factors of joint, rotation axis, and ΔCAW indicated complex joint motion patterns. The complex three-dimensional motion of the bones can be attributed to several anatomical constraints such as bone arrangement, ligament attachments, and articular congruence. The results of this study provide insight into the mechanisms of carpal tunnel adaptations in response to biomechanical alterations of the structural components.

  4. Ultra narrow bore thick film capillaries for microcolumn separations. Part 1. GC experiments

    NARCIS (Netherlands)

    Steenackers, D.; Sandra, P.J.F.; Sandra, P.; Devos, G.

    1993-01-01

    Ultra narrow bore (50 mum 1.0.) fused silica columns were statically coated with apolar stationary phases to obtain beta values ranging from 6.25 to 50 (filmthickness 2 to 0.25 mum). Performance of the 1 and 2 mum columns in Capillary Gas Chromatography (CGC) is highlighted.

  5. Controllable ultra-narrow fluorescence and six-wave mixing under double electromagnetically induced transparency

    International Nuclear Information System (INIS)

    Wang, Z G; Zhang, Z Y; Che, J L; Zhang, Y Z; Li, C B; Zheng, H B; Zhang, Y P

    2013-01-01

    We report the first observation of six-wave mixing (SWM) and fluorescence signals in an electromagnetically induced transparency (EIT) window. Several remarkable advantages are described. First, multiple bright and dark states are simultaneously observed due to enhancement or suppression of the SWM signal. Second, ultra-narrow fluorescence, much narrower than the EIT window, is experimentally obtained. Third, the ultra-narrow fluorescence can also generate Autler–Townes splitting on scanning the coupling beam. Fourth, a double-peak EIT window is obtained using the nest-dressing scheme. Such studies concerning SWM and fluorescence have applications in optical switching, multi-channel communication and narrowband and long-range quantum communication. (letter)

  6. Theoretical study on the ultra-narrow bandwidth tunable atomic filter with electromagnetically induced transparency

    Science.gov (United States)

    Liu, Yang; Li, Shu-qing; Feng, Zhong-ying; Liu, Xiao-fei; Gao, Jin-yue

    2016-12-01

    To obtain the weak signal light detection from the high background noise, we present a theoretical study on the ultra-narrow bandwidth tunable atomic filter with electromagnetically induced transparency. In a three-level Λ -type atomic system in the rubidium D1 line, the bandwidth of the EIT atomic filter is narrowed to ~6.5 \\text{MHz} . And the single peak transmission of the filter can be up to 86% . Moreover, the transmission wavelength can be tuned by changing the coupling light frequency. This theoretical scheme can also be applied to other alkali atomic systems.

  7. Impedance self-matching ultra-narrow linewidth fiber resonator by use of a tunable π-phase-shifted FBG.

    Science.gov (United States)

    Jing, Mingyong; Yu, Bo; Hu, Jianyong; Hou, Huifang; Zhang, Guofeng; Xiao, Liantuan; Jia, Suotang

    2017-05-15

    In this paper, we present a novel ultra-narrow linewidth fiber resonator formed by a tunable polarization maintaining (PM) π-phase-shifted fiber Bragg grating and a PM uniform fiber Bragg grating with a certain length of PM single mode fiber patch cable between them. Theoretical prediction shows that this resonator has ultra-narrow linewidth resonant peaks and is easy to realize impedance matching. We experimentally obtain 3 MHz narrow linewidth impedance matched resonant peak in a 7.3 m ultra-long passive fiber cavity. The impedance self-matching characteristic of this resonator also makes itself particularly suitable for use in ultra-sensitive sensors, ultra-narrow band rejection optical filters and fiber lasers applications.

  8. Ultra-narrow EIA spectra of 85Rb atom in a degenerate Zeeman multiplet system

    Science.gov (United States)

    Rehman, Hafeez Ur; Qureshi, Muhammad Mohsin; Noh, Heung-Ryoul; Kim, Jin-Tae

    2015-05-01

    Ultra-narrow EIA spectral features of thermal 85Rb atom with respect to coupling Rabi frequencies in a degenerate Zeeman multiplet system have been unraveled in the cases of same (σ+ -σ+ , π ∥ π) and orthogonal (σ+ -σ- , π ⊥ π)polarization configurations. The EIA signals with subnatural linewidth of ~ 100 kHz even in the cases of same circular and linear polarizations of coupling and probe laser have been obtained for the first time theoretically and experimentally. In weak coupling power limit of orthogonal polarization configurations, time-dependent transfer of coherence plays major role in the splitting of the EIA spectra while in strong coupling power, Mollow triplet-like mechanism due to strong power bring into broad split feature. The experimental ultra-narrow EIA features using one laser combined with an AOM match well with simulated spectra obtained by using generalized time-dependent optical Bloch equations.

  9. Ultra-narrow bandpass filters for long range optical telecommunications at 1064nm and 1550nm, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Ultra-narrow bandpass filters with high off-band rejection are needed to maximize signal to noise for free space communications. Omega Optical is developing NIR...

  10. Ultra-narrow band perfect absorbers based on Fano resonance in MIM metamaterials

    Science.gov (United States)

    Zhang, Ming; Fang, Jiawen; Zhang, Fei; Chen, Junyan; Yu, Honglin

    2017-12-01

    Metallic nanostructures have attracted numerous attentions in the past decades due to their attractive plasmonic properties. Resonant plasmonic perfect absorbers have promising applications in a wide range of technologies including photothermal therapy, thermophotovoltaics, heat-assisted magnetic recording and biosensing. However, it remains to be a great challenge to achieve ultra-narrow band in near-infrared band with plasmonic materials due to the large optical losses in metals. In this letter, we introduced Fano resonance in MIM metamaterials composed of an asymmetry double elliptic cylinders (ADEC), which can achieve ultra-narrow band perfect absorbers. In theoretical calculations, we observed an ultranarrow band resonant absorption peak with the full width at half maximum (FWHM) of 8 nm and absorption amplitude exceeding 99% at 930 nm. Moreover, we demonstrate that the absorption increases with the increase of asymmetry and the absorption resonant wavelength can be tuned by changing the size and arrangement of the unit cell. The asymmetry metallic nanostructure also exhibit a higher refractive sensitivity as large as 503 nm/RIU with high figure of merit of 63, which is promising for high sensitive sensors. Results of this work are desirable for various potential applications in micro-technological structures such as biological sensors, narrowband emission, photodetectors and solar thermophotovoltaic (STPV) cells.

  11. Modeling and validation of multiple joint reflections for ultra- narrow gap laser welding

    Energy Technology Data Exchange (ETDEWEB)

    Milewski, J.; Keel, G. [Los Alamos National Lab., NM (United States); Sklar, E. [Opticad Corp., Santa Fe, New Mexico (United States)

    1995-12-01

    The effects of multiple internal reflections within a laser weld joint as a function of joint geometry and processing conditions have been characterized. A computer model utilizing optical ray tracing is used to predict the reflective propagation of laser beam energy focused into the narrow gap of a metal joint for the purpose of predicting the location of melting and coalescence which form the weld. The model allows quantitative analysis of the effects of changes to joint geometry, laser design, materials and processing variables. This analysis method is proposed as a way to enhance process efficiency and design laser welds which display deep penetration and high depth to width aspect ratios, reduced occurrence of defects and enhanced melting. Of particular interest to laser welding is the enhancement of energy coupling to highly reflective materials. The weld joint is designed to act as an optical element which propagates and concentrates the laser energy deep within the joint to be welded. Experimentation has shown that it is possible to produce welds using multiple passes to achieve deep penetration and high depth to width aspect ratios without the use of filler material. The enhanced laser melting and welding of aluminum has been demonstrated. Optimization through modeling and experimental validation has resulted in the development of a laser welding process variant we refer to as Ultra-Narrow Gap Laser Welding.

  12. On the channel width-dependence of the thermal conductivity in ultra-narrow graphene nanoribbons

    Energy Technology Data Exchange (ETDEWEB)

    Karamitaheri, Hossein [Department of Electrical Engineering, University of Kashan, Kashan 87317-53153 (Iran, Islamic Republic of); Neophytou, Neophytos, E-mail: N.Neophytou@warwick.ac.uk [School of Engineering, University of Warwick, Coventry CV4 7AL (United Kingdom)

    2016-08-08

    The thermal conductivity of low-dimensional materials and graphene nanoribbons, in particular, is limited by the strength of line-edge-roughness scattering. One way to characterize the roughness strength is the dependency of the thermal conductivity on the channel's width in the form W{sup β}. Although in the case of electronic transport, this dependency is very well studied, resulting in W{sup 6} for nanowires and quantum wells and W{sup 4} for nanoribbons, in the case of phonon transport it is not yet clear what this dependence is. In this work, using lattice dynamics and Non-Equilibrium Green's Function simulations, we examine the width dependence of the thermal conductivity of ultra-narrow graphene nanoribbons under the influence of line edge-roughness. We show that the exponent β is in fact not a single well-defined number, but it is different for different parts of the phonon spectrum depending on whether phonon transport is ballistic, diffusive, or localized. The exponent β takes values β < 1 for semi-ballistic phonon transport, values β ≫ 1 for sub-diffusive or localized phonons, and β = 1 only in the case where the transport is diffusive. The overall W{sup β} dependence of the thermal conductivity is determined by the width-dependence of the dominant phonon modes (usually the acoustic ones). We show that due to the long phonon mean-free-paths, the width-dependence of thermal conductivity becomes a channel length dependent property, because the channel length determines whether transport is ballistic, diffusive, or localized.

  13. Ultra-narrow band diode lasers with arbitrary pulse shape modulation (Conference Presentation)

    Science.gov (United States)

    Ryasnyanskiy, Aleksandr I.; Smirnov, Vadim; Mokhun, Oleksiy; Glebov, Alexei L.; Glebov, Leon B.

    2017-03-01

    Wideband emission spectra of laser diode bars (several nanometers) can be largely narrowed by the usage of thick volume Bragg gratings (VBGs) recorded in photo-thermo-refractive glass. Such narrowband systems, with GHz-wide emission spectra, found broad applications for Diode Pumped Alkali vapor Lasers, optically pumped rare gas metastable lasers, Spin Exchange Optical Pumping, atom cooling, etc. Although the majority of current applications of narrow line diode lasers require CW operation, there are a variety of fields where operation in a different pulse mode regime is necessary. Commercial electric pulse generators can provide arbitrary current pulse profiles (sinusoidal, rectangular, triangular and their combinations). The pulse duration and repetition rate however, have an influence on the laser diode temperature, and therefore, the emitting wavelength. Thus, a detailed analysis is needed to understand the correspondence between the optical pulse profiles from a diode laser and the current pulse profiles; how the pulse profile and duty cycle affects the laser performance (e.g. the wavelength stability, signal to noise ratio, power stability etc.). We present the results of detailed studies of the narrowband laser diode performance operating in different temporal regimes with arbitrary pulse profiles. The developed narrowband (16 pm) tunable laser systems at 795 nm are capable of operating in different pulse regimes while keeping the linewidth, wavelength, and signal-to-noise ratio (>20 dB) similar to the corresponding CW modules.

  14. Generation of narrow energy spread ion beams via collisionless shock waves using ultra-intense 1 um wavelength laser systems

    Science.gov (United States)

    Albert, Felicie; Pak, A.; Kerr, S.; Lemos, N.; Link, A.; Patel, P.; Pollock, B. B.; Haberberger, D.; Froula, D.; Gauthier, M.; Glenzer, S. H.; Longman, A.; Manzoor, L.; Fedosejevs, R.; Tochitsky, S.; Joshi, C.; Fiuza, F.

    2017-10-01

    In this work, we report on electrostatic collisionless shock wave acceleration experiments that produced proton beams with peak energies between 10-17.5 MeV, with narrow energy spreads between Δ E / E of 10-20%, and with a total number of protons in these peaks of 1e7-1e8. These beams of ions were created by driving an electrostatic collisionless shock wave in a tailored near critical density plasma target using the ultra-intense ps duration Titan laser that operates at a wavelength of 1 um. The near critical density target was produced through the ablation of an initially 0.5 um thick Mylar foil with a separate low intensity laser. A narrow energy spread distribution of carbon / oxygen ions with a similar velocity to the accelerated proton distribution, consistent with the reflection and acceleration of ions from an electrostatic field, was also observed. This work was supported by Lawrence Livermore National Laboratory's Laboratory Directed Research and Development program under project 15-LW-095, and the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA2734.

  15. Frequency-bin entanglement of ultra-narrow band non-degenerate photon pairs

    Science.gov (United States)

    Rieländer, Daniel; Lenhard, Andreas; Jime`nez Farìas, Osvaldo; Máttar, Alejandro; Cavalcanti, Daniel; Mazzera, Margherita; Acín, Antonio; de Riedmatten, Hugues

    2018-01-01

    We demonstrate frequency-bin entanglement between ultra-narrowband photons generated by cavity enhanced spontaneous parametric down conversion. Our source generates photon pairs in widely non-degenerate discrete frequency modes, with one photon resonant with a quantum memory material based on praseodymium doped crystals and the other photon at telecom wavelengths. Correlations between the frequency modes are analyzed using phase modulators and narrowband filters before detection. We show high-visibility two photon interference between the frequency modes, allowing us to infer a coherent superposition of the modes. We develop a model describing the state that we create and use it to estimate optimal measurements to achieve a violation of the Clauser-Horne (CH) Bell inequality under realistic assumptions. With these settings we perform a Bell test and show a significant violation of the CH inequality, thus proving the entanglement of the photons. Finally we demonstrate the compatibility with a quantum memory material by using a spectral hole in the praseodymium (Pr) doped crystal as spectral filter for measuring high-visibility two-photon interference. This demonstrates the feasibility of combining frequency-bin entangled photon pairs with Pr-based solid state quantum memories.

  16. Coherent and non coherent atom optics experiment with an ultra-narrow beam of metastable rare gas atoms

    International Nuclear Information System (INIS)

    Grucker, J.

    2007-12-01

    In this thesis, we present a new type of atomic source: an ultra-narrow beam of metastable atoms produced by resonant metastability exchange inside a supersonic beam of rare gas atoms. We used the coherence properties of this beam to observe the diffraction of metastable helium, argon and neon atoms by a nano-transmission grating and by micro-reflection-gratings. Then, we evidenced transitions between Zeeman sublevels of neon metastable 3 P 2 state due to the quadrupolar part of Van der Waals potential. After we showed experimental proofs of the observation of this phenomenon, we calculated the transition probabilities in the Landau - Zener model. We discussed the interest of Van der Waals - Zeeman transitions for atom interferometry. Last, we described the Zeeman cooling of the supersonic metastable argon beam ( 3 P 2 ). We have succeeded in slowing down atoms to speeds below 100 m/s. We gave experimental details and showed the first time-of-flight measurements of slowed atoms

  17. Widely tunable single-/dual-wavelength fiber lasers with ultra-narrow linewidth and high OSNR using high quality passive subring cavity and novel tuning method.

    Science.gov (United States)

    Feng, Ting; Ding, Dongliang; Yan, Fengping; Zhao, Ziwei; Su, Hongxin; Yao, X Steve

    2016-08-22

    High stability single- and dual-wavelength compound cavity erbium-doped fiber lasers (EDFLs) with ultra-narrow linewidth, high optical signal to noise ratio (OSNR) and widely tunable range are demonstrated. Different from using traditional cascaded Type-1/Type-2 fiber rings as secondary cavities, we nest a Type-1 ring inside a Type-2 ring to form a passive subring cavity to achieve single-longitudinal-mode (SLM) lasing with ultra-narrow linewidth for the first time. We also show that the SLM lasing stability can be further improved by inserting a length of polarization maintaining fiber in the Type-2 ring. Using a uniform fiber Bragg grating (FBG) and two superimposed FBGs as mode restricting elements, respectively, we obtain a single-wavelength EDFL with a linewidth as narrow as 715 Hz and an OSNR as high as 73 dB, and a dual-wavelength EDFL with linewidths less than 1 kHz and OSNRs higher than 68 dB for both lasing wavelengths. Finally, by employing a novel self-designed strain adjustment device capable of applying both the compression and tension forces to the FBGs for wavelength tuning, we achieve the tuning range larger than 10 nm for both of the EDFLs.

  18. Viabilidade econômica da produção de palma forrageira irrigada e adensada no semiárido Potiguar = Economic feasibility of irrigated forage cactus in narrow rows in the Potiguar semiarid

    Directory of Open Access Journals (Sweden)

    Suênia Flávia de Araújo Dantas

    2017-01-01

    Full Text Available O semiárido potiguar pode ser uma excelente alternativa para a implantação de projetos de produção de palma irrigada e adensada por apresentar, em grande parte de seu território, clima desfavorável a produção dessa cultura em sistema de sequeiro. A irrigação e adensamento surge como uma alternativa viável economicamente para investidores. Assim, teve-se como objetivo estudar a viabilidade econômica da produção da palma forrageira irrigada e adensada no semiárido potiguar. A partir da análise dos dados, foi considerado o custo de produção de um hectare no município de Apodi, Rio Grande do Norte. No projeto foram analisados o investimento, custos de manutenção, rentabilidade e estimativa de crescimento ao longo de oito anos. Por meio de fluxo de caixa, considerando taxa mínima de atratividade de 8%, foram obtidos o Valor Presente Líquido [VPL], taxa interna de retorno [TIR] e o payback, assim como o cálculo do ponto de nivelamento. O projeto foi considerado economicamente viável, com a constatação de VPL igual a R$ 105.892,49 e TIR de 88%. O lucro líquido anual do projeto alcançou R$ 22.552,20, o que acumulado durante oito anos pode atingir R$ 158.319,80. Com base no payback o investidor teria retorno do investimento inicial em um ano e nove meses. A produtividade mínima para que a atividade desse lucro foi de 70.103 kg ha-1.ano-1. = The Potiguar semiarid can be an excellent alternative, in great part of its territory, to implement projects of irrigated forage cactus in narrow rows because of the unfavorable weather to the production of this crop in rainfed system. Narrowing and irrigating come as feasible alternatives to investors. Thus, the objective was to study the economic feasibility of irrigated forage cactus production in narrow rows in the Potiguar semiarid. It was considered the production cost of one hectare based on the data collected in the city of Apodi, Rio Grande do Norte. In the project, it was

  19. Full-sky survey searching for ultra-narrow-band artificial CW signals: analysis of the results of Project META

    Science.gov (United States)

    Lemarchand, Guillermo A.

    1996-06-01

    Project META (Megachannel ExtraTerrestrial Assay), a full-sky survey for artificial narrow-band signals, has been conducted from the Harvard/Smithsonian 26 m radiotelescope at Agassiz Station and from one of the two 30 m radiotelescopes of the Instituto Argentino de Radioastronomia (IAR). The search was performed near the 1420 MHz line of neutral hydrogen, and its second harmonic, using two 8.4 X 10(superscript 6) channel Fourier spectrometers of 0.05 Hz resolution and 400 kHz of instantaneous bandwidth. The observing frequency was corrected both for motions with respect to three astronomical inertial frames, and for the effect of Earth's rotation, which provides a characteristic changing signature for narrow-band signals of extraterrestrial origin. Among the 6 X 10(superscript 13) spectral channels searched in the northern hemisphere, Horowitz and Sagan reported 37 candidates events exceeding the average threshold of 1.7 X 10(superscript -23) W m(superscript -2), while in the southern hemisphere among 2 X 10(superscript 13) spectral channels analyzed we found 19 events exceeding the same threshold. The strongest signals that survive culling for terrestrial interference lie in or near the Galactic Plane. The first high resolution southern target search around 71 stars (-90 degrees intelligence. It is showed that these narrow-band non-repeating 'events' found by Project META can be generated by (a) radiometer noise fluctuations, (b) a population of constant galactic sources which undergo deep fading and amplification due to interstellar scintillation, consistent with ETI transmissions and (c) real, transient signals of either terrestrial or extraterrestrial origin. The Bayesian test shows that hypothesis (b) and (c) are both highly preferred to (a), but the first two are about equally likely. Using this analysis we discuss the best observing strategies to determine the real origin of these 'events'.

  20. Tunneling magnetoresistance of ultra-thin Co-SiO2 granular films with narrow current channels

    International Nuclear Information System (INIS)

    Honda, S.; Hirata, M.; Ishimaru, M.

    2005-01-01

    We have constructed the tunneling magnetoresistance (TMR) junction of AuCr/SiO 2 /Co-SiO 2 /SiO 2 /AuCr with narrow current channels, where the TMR occurs in the Co-SiO 2 layer with 10-50 nm thickness. The magnetic properties are independent of thickness, while the TMR properties depend fairly on thickness. The current (I)-bias voltage (V B ) curve is nonlinear, namely the differential resistivity decreases with increasing V B , and also the magnetoresistance ratio decreases

  1. ULTRA-NARROW NEGATIVE FLARE FRONT OBSERVED IN HELIUM-10830 Å USING THE 1.6 m NEW SOLAR TELESCOPE

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yan; Liu, Chang; Jing, Ju; Wang, Haimin [Space Weather Research Lab, Center for Solar-Terrestrial Research, New Jersey Institute of Technology, 323 Martin Luther King Blvd, Newark, NJ 07102-1982 (United States); Cao, Wenda; Gary, Dale [Big Bear Solar Observatory, New Jersey Institute of Technology 323 Martin Luther King Blvd, Newark, NJ 07102-1982 (United States); Ding, Mingde [School of Astronomy and Space Science, Nanjing University, Nanjing 210093 (China); Kleint, Lucia [Fachhochschule Nordwestschweiz (FHNW), Institute of 4D technologies Bahnhofstr. 6, CH-5210 Windisch (Switzerland); Su, Jiangtao [Key Laboratory of Solar Activity, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China); Ji, Haisheng [Purple Mountain Observatory, 2 Beijing Xi Lu, Nanjing, 210008 (China); Chae, Jongchul; Cho, Kyuhyoun [Astronomy Program, Department of Physics and Astronomy, Seoul National University, Seoul 151-747 (Korea, Republic of); Cho, Kyungsuk [Korea Astronomy and Space Science Institute, Daedeokdae-ro 776, Yuseong-gu, Daejeon 305-348 (Korea, Republic of)

    2016-03-10

    Solar flares are sudden flashes of brightness on the Sun and are often associated with coronal mass ejections and solar energetic particles that have adverse effects on the near-Earth environment. By definition, flares are usually referred to as bright features resulting from excess emission. Using the newly commissioned 1.6 m New Solar Telescope at Big Bear Solar Observatory, we show a striking “negative” flare with a narrow but unambiguous “dark” moving front observed in He i 10830 Å, which is as narrow as 340 km and is associated with distinct spectral characteristics in Hα and Mg ii lines. Theoretically, such negative contrast in He i 10830 Å can be produced under special circumstances by nonthermal electron collisions or photoionization followed by recombination. Our discovery, made possible due to unprecedented spatial resolution, confirms the presence of the required plasma conditions and provides unique information in understanding the energy release and radiative transfer in astronomical objects.

  2. ULTRA-NARROW NEGATIVE FLARE FRONT OBSERVED IN HELIUM-10830 Å USING THE 1.6 m NEW SOLAR TELESCOPE

    International Nuclear Information System (INIS)

    Xu, Yan; Liu, Chang; Jing, Ju; Wang, Haimin; Cao, Wenda; Gary, Dale; Ding, Mingde; Kleint, Lucia; Su, Jiangtao; Ji, Haisheng; Chae, Jongchul; Cho, Kyuhyoun; Cho, Kyungsuk

    2016-01-01

    Solar flares are sudden flashes of brightness on the Sun and are often associated with coronal mass ejections and solar energetic particles that have adverse effects on the near-Earth environment. By definition, flares are usually referred to as bright features resulting from excess emission. Using the newly commissioned 1.6 m New Solar Telescope at Big Bear Solar Observatory, we show a striking “negative” flare with a narrow but unambiguous “dark” moving front observed in He i 10830 Å, which is as narrow as 340 km and is associated with distinct spectral characteristics in Hα and Mg ii lines. Theoretically, such negative contrast in He i 10830 Å can be produced under special circumstances by nonthermal electron collisions or photoionization followed by recombination. Our discovery, made possible due to unprecedented spatial resolution, confirms the presence of the required plasma conditions and provides unique information in understanding the energy release and radiative transfer in astronomical objects

  3. PLANT DENSITY AND AGRONOMIC TRAITS OF MAIZE HYBRIDS IN NARROW ROW SPACING DENSIDADE DE PLANTAS E CARACTERÍSTICAS AGRONÔMICAS DE HÍBRIDOS DE MILHO SOB ESPAÇAMENTO REDUZIDO ENTRE LINHAS

    Directory of Open Access Journals (Sweden)

    Cleber Morais Guimarães

    2007-09-01

    Full Text Available

    The objective of this study was to evaluate the behavior of maize hybrids cultivated under different population densities in narrow row spacing (0.45 m. Two field experiments were installed to evaluate six commercial hybrids (A 2555, A 2288, AG 9010, AG 6690, P 30F88 and Valent grown in five plant densities (40,000; 53,000; 71,000; 84,000; and 97,000 plants per hectare, in Goiânia and Jataí, Goiás State, during the growing season of 2002/2003. The experimental design was a randomized complete blocks, arranged in a 6x5 factorial design with four replicates. In the Goiânia experiment, the treatments were carried out using a split plot design. In the experiment of Goiânia, the treatments were carried out using a split plot design. The means of ear insertion, plant height, stalk lodging, ear length, ear diameter, corncob diameter, kernels per ear, weight of 100 kernels and grain yield was significantly influenced by plant density in both experiments. Grain yield was increased for plant densities higher than 70,000 plants per hectare, indicating that the use of narrow row spacing associated to the presence of shorter plant stature hybrids, favors enhancements in plant density. The grain yield was significantly affected by the interaction between hybrid and plant density in both fields. This indicates that, depending of the hybrid, the reduction of row spacing to 0.45 m is a managing practice that allows an increment in the sowing density.

    KEY-WORDS: Zea mays; cultivar; plant arrangement; agronomic trait; grain yield.

    O objetivo deste trabalho foi avaliar o comportamento de híbridos de milho (A 2555, A 2288, AG 9010, AG 6690, P 30F88 e Valent, cultivados em diferentes densidades populacionais (40 mil, 53 mil, 71 mil, 84 mil e 97 mil plantas por hectare e sob espaçamento reduzido

  4. Power and polarization dependences of ultra-narrow electromagnetically induced absorption (EIA) spectra of 85 Rb atoms in degenerate two-level system

    Science.gov (United States)

    Qureshi, Muhammad Mohsin; Rehman, Hafeez Ur; Noh, Heung-Ryoul; Kim, Jin-Tae

    2016-05-01

    We have investigated ultra-narrow EIA spectral features with respect to variations of polarizations and powers of pump laser beam in a degenerate two-level system of the transition of 85 Rb D2 transition line. Polarizations of the probe laser beam in two separate experiments were fixed at right circular and horizontal linear polarizations, respectively while the polarizations of the pump lasers were varied from initial polarizations same as the probe laser beams to orthogonal to probe polarizations. One homemade laser combined with AOMs was used to the pump and probe laser beams instead of two different lasers to overcome broad linewidths of the homemade lasers. Theoretically, probe absorption coefficients have been calculated from optical Bloch equations of the degenerate two level system prepared by a pump laser beam. In the case of the circular polarization, EIA signal was obtained as expected theoretically although both pump and probe beams have same polarization. The EIA signal become smaller as power increases and polarizations of the pump and probe beams were same. When the polarization of the pump beam was linear polarization, maximum EIA signal was obtained theoretically and experimentally. Experimental EIA spectral shapes with respect to variations of the pump beam polarization shows similar trends as the theoretical results.

  5. Row fault detection system

    Science.gov (United States)

    Archer, Charles Jens [Rochester, MN; Pinnow, Kurt Walter [Rochester, MN; Ratterman, Joseph D [Rochester, MN; Smith, Brian Edward [Rochester, MN

    2008-10-14

    An apparatus, program product and method checks for nodal faults in a row of nodes by causing each node in the row to concurrently communicate with its adjacent neighbor nodes in the row. The communications are analyzed to determine a presence of a faulty node or connection.

  6. Suicide on Death Row.

    Science.gov (United States)

    Tartaro, Christine; Lester, David

    2016-11-01

    Despite the level of supervision of inmates on death row, their suicide rate is higher than both the male prison population in the United States and the population of males over the age of 14 in free society. This study presents suicide data for death row inmates from 1978 through 2010. For the years 1978 through 2010, suicide rates on death row were higher than that for the general population of males over the age of 15 and for state prisons for all but 2 years. © 2016 American Academy of Forensic Sciences.

  7. Yellapragada SubbaRow

    Indian Academy of Sciences (India)

    Admin

    filariasis, needs to use tetracycline antibiotics against plague and bacterial ... mouth existence. Deeply affected by poverty at home, SubbaRow .... which forced him to stay on deck during the journey. He was the ..... pregnant women of.

  8. Reduced dosages of atrazine and narrow rows can provide ...

    African Journals Online (AJOL)

    hope&shola

    2010-11-08

    Nov 8, 2010 ... chores to tend to the sick and attend funerals. (Mashingaidze, 2004). ... RHDs reduce crop injury, risk of contamination in the ecosystem ..... Olifants River Basin of Limpopo Province: Management, Transfer,. Productivity ...

  9. Coherent and non coherent atom optics experiment with an ultra-narrow beam of metastable rare gas atoms; Experiences d'optique atomique coherente ou non avec un jet superfin d'atomes metastables de gaz rares

    Energy Technology Data Exchange (ETDEWEB)

    Grucker, J

    2007-12-15

    In this thesis, we present a new type of atomic source: an ultra-narrow beam of metastable atoms produced by resonant metastability exchange inside a supersonic beam of rare gas atoms. We used the coherence properties of this beam to observe the diffraction of metastable helium, argon and neon atoms by a nano-transmission grating and by micro-reflection-gratings. Then, we evidenced transitions between Zeeman sublevels of neon metastable {sup 3}P{sub 2} state due to the quadrupolar part of Van der Waals potential. After we showed experimental proofs of the observation of this phenomenon, we calculated the transition probabilities in the Landau - Zener model. We discussed the interest of Van der Waals - Zeeman transitions for atom interferometry. Last, we described the Zeeman cooling of the supersonic metastable argon beam ({sup 3}P{sub 2}). We have succeeded in slowing down atoms to speeds below 100 m/s. We gave experimental details and showed the first time-of-flight measurements of slowed atoms.

  10. Essential oil and composition of anise (pimpinella anisum l.) with varying seed rates and row spacing

    International Nuclear Information System (INIS)

    Ullah, H.

    2014-01-01

    Two year study was carried out to explore the effect of seed rate and row spacing on the fruit yield, essential oil yield and composition of aniseed. The study factors included seed rate (6 g, 12 g, 24 g/10 m2) and row spacing (15 cm, 25 cm, 37.5 cm. A significantly higher fruit yield was produced at narrow row spacing of 15 cm among treatments. Wider row spacing produced markedly higher essential oil than narrow row spacing. Essential oil accumulation decreased as planting densities increased. The major constituent of anise oil was trans-anethole (82.1%) followed by himachalene (7.0%). The quality parameters including estragol, himachalene and trans-anethole were significantly affected by different row spacing. Plant grown at 37.5 cm row spacing accumulated the highest estragol and trans-anethole concentration among the row spacing treatments. It can be concluded that higher plant density and wider row spacing increased the disease infestation and lodging cultivar Enza Zaden in current study exhibited high concentration trans-anethole in essential oil composition therefore is a good quality chemotype. (author)

  11. The Demise of Skid Row.

    Science.gov (United States)

    Siegal, Harvey A.; Inciardi, James A.

    1982-01-01

    Describes the history and evolution of the American skid row; analyzes the changes it has undergone, particularly in the face of urban renewal; and speculates on its future. Includes opinions of the inhabitants of skid row which were obtained from interviews. (MJL)

  12. Training Rowing with Virtual Environments

    Directory of Open Access Journals (Sweden)

    Gopher Daniel

    2011-12-01

    Full Text Available This paper presents the results of the design, implementation and evaluation of a platform for rowing training in Virtual Reality called SPRINT. The paper discusses how various aspects of the rowing skill can be analyzed and trained over a single common methodology and system platform. The result is a vision for new directions in the domain of sport training with Virtual Reality.

  13. Slide-based ergometer rowing

    DEFF Research Database (Denmark)

    Vinther, Anders; Alkjær, T; Kanstrup, I-L

    2012-01-01

    Force production profile and neuromuscular activity during slide-based and stationary ergometer rowing at standardized submaximal power output were compared in 14 male and 8 female National Team rowers. Surface electromyography (EMG) was obtained in selected thoracic and leg muscles along with sy...

  14. Mechanical performance of aquatic rowing and flying.

    Science.gov (United States)

    Walker, J A; Westneat, M W

    2000-09-22

    Aquatic flight, performed by rowing or flapping fins, wings or limbs, is a primary locomotor mechanism for many animals. We used a computer simulation to compare the mechanical performance of rowing and flapping appendages across a range of speeds. Flapping appendages proved to be more mechanically efficient than rowing appendages at all swimming speeds, suggesting that animals that frequently engage in locomotor behaviours that require energy conservation should employ a flapping stroke. The lower efficiency of rowing appendages across all speeds begs the question of why rowing occurs at all. One answer lies in the ability of rowing fins to generate more thrust than flapping fins during the power stroke. Large forces are necessary for manoeuvring behaviours such as accelerations, turning and braking, which suggests that rowing should be found in slow-swimming animals that frequently manoeuvre. The predictions of the model are supported by observed patterns of behavioural variation among rowing and flapping vertebrates.

  15. Ergometer rowing with and without slides

    DEFF Research Database (Denmark)

    Larsen, Anders Holsgaard; Jensen, K

    2010-01-01

    A rowing ergometer can be placed on a slide to imitate 'on-water' rowing. The present study examines I) possible differences in biomechanical and physiological variables of ergometer rowing with and without slides and II) potential consequences on training load during exercise. 7 elite oars......-women rowed in a randomized order in a slide or stationary ergometer at 3 predefined submaximal and at maximal intensity. Oxygen uptake was measured and biomechanical variables of the rowing were calculated based upon handle force (force transducer) and velocity/length (potentiometer) of the stroke. Stroke...

  16. A New Hoe Blade for Inter-Row Weeding

    DEFF Research Database (Denmark)

    Green, O.; Znova, L.; Melander, Bo

    2016-01-01

    and weeds are relatively small. The term ‘Ducksfoot’ covers a range of hoe blade configurations where all have some resemblance with the shape of a ducks foot. However, the ‘Ducksfoot’ blade is not an optimal solution for weed control in narrow inter-row spaces. Several disadvantages have been encountered...... and the draft forces needed to pull it were approx. half those measured for a ‘Ducksfoot’ blade. The weeding features of the new L-blade will be further studied under field conditions....

  17. Double-row vs single-row rotator cuff repair: a review of the biomechanical evidence.

    Science.gov (United States)

    Wall, Lindley B; Keener, Jay D; Brophy, Robert H

    2009-01-01

    A review of the current literature will show a difference between the biomechanical properties of double-row and single-row rotator cuff repairs. Rotator cuff tears commonly necessitate surgical repair; however, the optimal technique for repair continues to be investigated. Recently, double-row repairs have been considered an alternative to single-row repair, allowing a greater coverage area for healing and a possibly stronger repair. We reviewed the literature of all biomechanical studies comparing double-row vs single-row repair techniques. Inclusion criteria included studies using cadaveric, animal, or human models that directly compared double-row vs single-row repair techniques, written in the English language, and published in peer reviewed journals. Identified articles were reviewed to provide a comprehensive conclusion of the biomechanical strength and integrity of the repair techniques. Fifteen studies were identified and reviewed. Nine studies showed a statistically significant advantage to a double-row repair with regards to biomechanical strength, failure, and gap formation. Three studies produced results that did not show any statistical advantage. Five studies that directly compared footprint reconstruction all demonstrated that the double-row repair was superior to a single-row repair in restoring anatomy. The current literature reveals that the biomechanical properties of a double-row rotator cuff repair are superior to a single-row repair. Basic Science Study, SRH = Single vs. Double Row RCR.

  18. Narrow dibaryon resonances

    International Nuclear Information System (INIS)

    Kajdalov, A.B.

    1986-01-01

    Experimental data on np interactions indicating to existence of narrow resonances in pp-system are discussed. Possible theoretical interpretations of these resonances are given. Experimental characteristics of the dibaryon resonances with isospin I=2 are considered

  19. Prosodic Function Row in Persian Poetry

    Directory of Open Access Journals (Sweden)

    Majid Mansouri

    2017-04-01

    The main reason for the emergence of rows in Persian poetry is its prosodic function that has already been paid less. I just found something in the book Ghosn al-ban which the author had some similar view to the row. In this study, we made our attempt to show another reason for the entry and spread of the row in Persian poetry by means of a new approach. It should also be noted that in these lines to avoid as much as possible the repetitive and stereotyped points regarding the row.

  20. An optimization of the FPGA/NIOS adaptive FIR filter using linear prediction to reduce narrow band RFI for the next generation ground-based ultra-high energy cosmic-ray experiment

    Energy Technology Data Exchange (ETDEWEB)

    Szadkowski, Zbigniew, E-mail: zszadkow@kfd2.phys.uni.lodz.pl [University of Lodz, Department of Physics and Applied Informatics (Poland); Fraenkel, E.D. [Kernfysisch Versneller Instituut of the University of Groningen, Groningen (Netherlands); Glas, Dariusz; Legumina, Remigiusz [University of Lodz, Department of Physics and Applied Informatics (Poland)

    2013-12-21

    The electromagnetic part of an extensive air shower developing in the atmosphere provides significant information complementary to that obtained by water Cherenkov detectors which are predominantly sensitive to the muonic content of an air shower at ground. The emissions can be observed in the frequency band between 10 and 100 MHz. However, this frequency range is significantly contaminated by narrow-band RFI and other human-made distortions. The Auger Engineering Radio Array currently suppresses the RFI by multiple time-to-frequency domain conversions using an FFT procedure as well as by a set of manually chosen IIR notch filters in the time-domain. An alternative approach developed in this paper is an adaptive FIR filter based on linear prediction (LP). The coefficients for the linear predictor are dynamically refreshed and calculated in the virtual NIOS processor. The radio detector is an autonomous system installed on the Argentinean pampas and supplied from a solar panel. Powerful calculation capacity inside the FPGA is a factor. Power consumption versus the degree of effectiveness of the calculation inside the FPGA is a figure of merit to be minimized. Results show that the RFI contamination can be significantly suppressed by the LP FIR filter for 64 or less stages. -- Highlights: • We propose an adaptive method using linear prediction for periodic RFI suppression. • Requirements are the detection of short transient signals powered by solar panels. • The RFI is significantly suppressed by ∼70%, even in a very contaminated environment. • This method consumes less energy than the current method based on FFT used in AERA. • Distortion of the short transient signals is negligible.

  1. Jihadism, Narrow and Wide

    DEFF Research Database (Denmark)

    Sedgwick, Mark

    2015-01-01

    The term “jihadism” is popular, but difficult. It has narrow senses, which are generally valuable, and wide senses, which may be misleading. This article looks at the derivation and use of “jihadism” and of related terms, at definitions provided by a number of leading scholars, and at media usage....... It distinguishes two main groups of scholarly definitions, some careful and narrow, and some appearing to match loose media usage. However, it shows that even these scholarly definitions actually make important distinctions between jihadism and associated political and theological ideology. The article closes...

  2. On Importance of Rows for Decision Tables

    KAUST Repository

    AbouEisha, Hassan M.; Azad, Mohammad; Moshkov, Mikhail

    2017-01-01

    In this paper, we propose a method for the evaluation of importance of rows for decision tables. It is based on indirect information about changes in the set of reducts after removing the considered row from the table. We also discuss results of computer experiments with decision tables from UCI Machine Learning Repository.

  3. Rasch models with exchangeable rows and columns

    DEFF Research Database (Denmark)

    Lauritzen, Steffen Lilholt

    The article studies distributions of doubly infinite binary matrices with exchangeable rows and columns which satify the further property that the probability of any $m \\times n$ submatrix is a function of the row- and column sums of that matrix. We show that any such distribution is a (unique...

  4. Rowe's Argument from Improvability | Almeida | Philosophical Papers

    African Journals Online (AJOL)

    William Rowe has argued that if there is an infinite sequence of improving worlds then an essentially perfectly good being must actualize some world in the sequence and must not actualize any world in the sequence. Since that is impossible, there exist no perfectly good beings. I show that Rowe's argument assumes that ...

  5. On Importance of Rows for Decision Tables

    KAUST Repository

    AbouEisha, Hassan M.

    2017-06-21

    In this paper, we propose a method for the evaluation of importance of rows for decision tables. It is based on indirect information about changes in the set of reducts after removing the considered row from the table. We also discuss results of computer experiments with decision tables from UCI Machine Learning Repository.

  6. On Row Rank Equal Column Rank

    Science.gov (United States)

    Khalili, Parviz

    2009-01-01

    We will prove a well-known theorem in Linear Algebra, that is, for any "m x n" matrix the dimension of row space and column space are the same. The proof is based on the subject of "elementary matrices" and "reduced row-echelon" form of a matrix.

  7. Correlates of Narrow Bracketing

    DEFF Research Database (Denmark)

    Koch, Alexander; Nafziger, Julia

    We examine whether different phenomena of narrow bracketing can be traced back to some common characteristic and whether and how different phenomena are related. We find that making dominated lottery choices or ignoring the endowment when making risky choices are related phenomena and are both as...

  8. Importance of stand density, inter row spacing, "mother" and "father" row distance in corn seed production

    Directory of Open Access Journals (Sweden)

    Marinković Branko

    2006-01-01

    Full Text Available Importance of stand density, "mother" and "father" row distance is very important for corn seed production. Inter row spacing from 70,60 and 50 cm, and their influence on "mother" grain yield was investigated during 7 years trials. In seed production, at density ratio 6 + 2, beside inter row spacing, yield influence on stand density was followed as well. Five stand densities (40.8000, 52.900, 64.900, 79.400, 89.300, total plant number per ha and density ration 6 + 2, was investigated. The next results were obtained: at 70 cm inter row spacing, the highest yield was achieved with the 64.900 plant/ha stand density (4.35 tha-1 "mother" seed. At the first row, yield was higher for 360 and 550 kgha-1 in dependence from the second and the third "mother" row. At 60 cm inter row spacing, yield was increasing till the highest density, and significant difference, in relation to 40.800 plants/ha, was at 79.400 plants/ha stands density. At the second and the third row in rela­tion to the first "mother" row, yield difference was 430 and 510 kgha-1. The same conclusions can be made at the 50 cm inter row spacing. With the "mother" row space increasing, yield was decreased for 370 and 460 kgha-1.

  9. Characteristics of forming of synonymic rows within lexical phraseological field

    Directory of Open Access Journals (Sweden)

    Мария Валерьевна Волнакова

    2011-03-01

    Full Text Available The article deals with the characteristics of forming of phraseological synonymic rows with a lexical identifier as a dominant of a row. Revealed synonymic rows mirror the deepness of systematic language relationships between lexis and phraseology.

  10. The effects of ridging, row-spacing and seeding rate on carrot yield

    Directory of Open Access Journals (Sweden)

    S. TAIVALMAA

    2008-12-01

    Full Text Available Cool, wet spring weather often delays the early growth of carrots (Daucus carota L. in northern Europe. This effect may be partly obviated by sowing in ridges. Many types of ridges are used, but the most suitable for carrot cultivation under the conditions prevailing in northern Europe has yet to be determined. The effects of ridging, seeding rate and sowing system on the yield and visible quality of carrots were therefore studied in the field during three years. The highest yields were recorded for carrots sown in double rows on a narrow ridge. The effect of sowing system on mean root weight differed depending on the ridging regime. The mean weight of roots was higher for carrots cultivated on broad ridges than in other systems. Seeding rate had the most significant effect on mean root weight. For industrial purposes it is recommended that carrots be cultivated on broad ridges in double rows at low seeding rates with irrigation. The optimal cultivation technique for carrots destined for the fresh vegetable market would be narrow ridges sown in double rows at high seeding rates. The ridging system, seeding rate and row spacing did not appear to affect the external quality of roots. More detailed studies should be carried out to establish the effects of abiotic growth factors under different ridging regimes.;

  11. The effects of ridging, row-spacing and seeding rate on carrot yield

    Directory of Open Access Journals (Sweden)

    Sanna-Liisa Taivalmaa

    1997-12-01

    Full Text Available Cool, wet spring weather often delays the early growth of carrots (Daucus carota L. in northern Europe. This effect may be partly obviated by sowing in ridges. Many types of ridges are used, but the most suitable for carrot cultivation under the conditions prevailing in northern Europe has yet to be determined. The effects of ridging, seeding rate and sowing system on the yield and visible quality of carrots were therefore studied in the field during three years. The highest yields were recorded for carrots sown in double rows on a narrow ridge. The effect of sowing system on mean root weight differed depending on the ridging regime. The mean weight of roots was higher for carrots cultivated on broad ridges than in other systems. Seeding rate had the most significant effect on mean root weight. For industrial purposes it is recommended that carrots be cultivated on broad ridges in double rows at low seeding rates with irrigation. The optimal cultivation technique for carrots destined for the fresh vegetable market would be narrow ridges sown in double rows at high seeding rates. The ridging system, seeding rate and row spacing did not appear to affect the external quality of roots. More detailed studies should be carried out to establish the effects of abiotic growth factors under different ridging regimes.

  12. Single-row versus double-row rotator cuff repair: techniques and outcomes.

    Science.gov (United States)

    Dines, Joshua S; Bedi, Asheesh; ElAttrache, Neal S; Dines, David M

    2010-02-01

    Double-row rotator cuff repair techniques incorporate a medial and lateral row of suture anchors in the repair configuration. Biomechanical studies of double-row repair have shown increased load to failure, improved contact areas and pressures, and decreased gap formation at the healing enthesis, findings that have provided impetus for clinical studies comparing single-row with double-row repair. Clinical studies, however, have not yet demonstrated a substantial improvement over single-row repair with regard to either the degree of structural healing or functional outcomes. Although double-row repair may provide an improved mechanical environment for the healing enthesis, several confounding variables have complicated attempts to establish a definitive relationship with improved rates of healing. Appropriately powered rigorous level I studies that directly compare single-row with double-row techniques in matched tear patterns are necessary to further address these questions. These studies are needed to justify the potentially increased implant costs and surgical times associated with double-row rotator cuff repair.

  13. A comparative clinical evaluation of arthroscopic single-row versus double-row supraspinatus tendon repair.

    Science.gov (United States)

    Buess, Eduard; Waibl, Bernhard; Vogel, Roger; Seidner, Robert

    2009-10-01

    Cadaveric studies and commercial pressure have initiated a strong trend towards double-row repair in arthroscopic cuff surgery. The objective of this study was to evaluate if the biomechanical advantages of a double-row supraspinatus tendon repair would result in superior clinical outcome and higher abduction strength. A retrospective study of two groups of 32 single-row and 33 double-row repairs of small to medium cuff tears was performed. The Simple Shoulder Test (SST) and a visual analog scale for pain were used to evaluate the outcome. The participation rate was 100%. A subset of patients was further investigated with the Constant Score (CS) including electronic strength measurement. The double-row repair patients had significantly more (p = 0.01) yes answers in the SST than the single-row group, and pain reduction was slightly better (p = 0.03). No difference was found for the relative CS (p = 0.86) and abduction strength (p = 0.74). Patient satisfaction was 100% for double-row and 97% for single-row repair. Single- and double-row repairs both achieved excellent clinical results. Evidence of superiority of double-row repair is still scarce and has to be balanced against the added complexity of the procedure and higher costs.

  14. Single-row versus double-row repair of the distal Achilles tendon: a biomechanical comparison.

    Science.gov (United States)

    Pilson, Holly; Brown, Philip; Stitzel, Joel; Scott, Aaron

    2012-01-01

    Surgery for recalcitrant insertional Achilles tendinopathy often consists of partial or total release of the insertion site, debridement of the diseased portion of the tendon, calcaneal ostectomy, and reattachment of the Achilles to the calcaneus. Although single-row and double-row techniques exist for repair of the detached Achilles tendon, biomechanical data are lacking to support one technique over the other. Based on data extrapolated from the study of rotator cuff repairs, we hypothesized that a double-row construct would provide superior fixation strength over a single-row repair. Eighteen human cadaveric Achilles tendons (9 matched pairs) with attached calcanei were repaired with single-row or double-row techniques. Specimens were mounted in a servohydraulic materials testing machine, subjected to a preconditioning cycle, and loaded to failure. Failure was defined as suture breakage or pullout, midsubstance tendon rupture, or anchor pullout. Among the failures were 12 suture failures, 5 proximal-row anchor failures, and 1 distal-row anchor failure. No midsubstance tendon ruptures or testing apparatus failures were observed. There were no statistically significant differences in the peak load to failure between the single-row and double-row repairs (p = .46). Similarly, no significant differences were observed with regards to mean energy expenditure to failure (p = .069). The present study demonstrated no biomechanical advantages of the double-row repair over a single-row repair. Despite the lack of a clear biomechanical advantage, there may exist clinical advantages of a double-row repair, such as reduction in knot prominence and restoration of the Achilles footprint. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Memory hierarchy using row-based compression

    Science.gov (United States)

    Loh, Gabriel H.; O'Connor, James M.

    2016-10-25

    A system includes a first memory and a device coupleable to the first memory. The device includes a second memory to cache data from the first memory. The second memory includes a plurality of rows, each row including a corresponding set of compressed data blocks of non-uniform sizes and a corresponding set of tag blocks. Each tag block represents a corresponding compressed data block of the row. The device further includes decompression logic to decompress data blocks accessed from the second memory. The device further includes compression logic to compress data blocks to be stored in the second memory.

  16. A concept of row crater enhancement

    International Nuclear Information System (INIS)

    Redpath, B.B.

    1970-01-01

    Linear craters formed by the simultaneous detonation of a row of buried explosives will probably have a wider application than single charges in the explosive excavation of engineering structures. Most cratering experience to date has been with single charges, and an analytical procedure for the design of a row of charges to excavate a crater with a specified configuration has been lacking. There are no digital computer codes having direct application to a row of charges as there are for single charges. This paper derives a simple relationship which can be used to design row charges with some assurance of achieving the desired result and with considerable flexibility in the choice of explosive yield of the individual charges

  17. North Region ROW tool implementation workshop.

    Science.gov (United States)

    2010-08-02

    Welcome to the North Region ROW Tool Workshop. This workshop is funded under an implementation project sponsored by TxDOTs Research & Technology Implementation Office (RTI). This is the second of four regional workshops being planned for this summ...

  18. Incidence of retear with double-row versus single-row rotator cuff repair.

    Science.gov (United States)

    Shen, Chong; Tang, Zhi-Hong; Hu, Jun-Zu; Zou, Guo-Yao; Xiao, Rong-Chi

    2014-11-01

    Rotator cuff tears have a high recurrence rate, even after arthroscopic rotator cuff repair. Although some biomechanical evidence suggests the superiority of the double-row vs the single-row technique, clinical findings regarding these methods have been controversial. The purpose of this study was to determine whether the double-row repair method results in a lower incidence of recurrent tearing compared with the single-row method. Electronic databases were systematically searched to identify reports of randomized, controlled trials (RCTs) comparing single-row with double-row rotator cuff repair. The primary outcome assessed was retear of the repaired cuff. Secondary outcome measures were the American Shoulder and Elbow Surgeons (ASES) shoulder score, the Constant shoulder score, and the University of California, Los Angeles (UCLA) score. Heterogeneity between the included studies was assessed. Six studies involving 428 patients were included in the review. Compared with single-row repair, double-row repair demonstrated a lower retear incidence (risk ratio [RR]=1.71 [95% confidence interval (CI), 1.18-2.49]; P=.005; I(2)=0%) and a reduced incidence of partial-thickness retears (RR=2.16 [95% CI, 1.26-3.71]; P=.005; I(2)=26%). Functional ASES, Constant, and UCLA scores showed no difference between single- and double-row cuff repairs. Use of the double-row technique decreased the incidence of retears, especially partial-thickness retears, compared with the single-row technique. The functional outcome was not significantly different between the 2 techniques. To improve the structural outcome of the repaired rotator cuff, surgeons should use the double-row technique. However, further long-term RCTs on this topic are needed. Copyright 2014, SLACK Incorporated.

  19. Phase tracking system for ultra narrow bandwidth applications

    NARCIS (Netherlands)

    Hill, M.T.; Cantoni, A.

    2002-01-01

    Recent advances make it possible to mitigate a number of drawbacks of conventional phase locked loops. These advances permit the design of phase tracking systems with much improved characteristics that are sought after in modern communication system applications. A new phase tracking system is

  20. Narrow rows reduce biomass and seed production of weeds and increase maize yield

    NARCIS (Netherlands)

    Mashingaidze, A.B.; Werf, van der W.; Lotz, L.A.P.; Chipomho, J.; Kropff, M.J.

    2009-01-01

    Smallholder farmers in southern African countries rely primarily on cultural control and hoe weeding to combat weeds, but often times, they are unable to keep up with the weeding requirements of the crop because of its laboriousness, causing them to incur major yield losses. Optimisation of crop

  1. Comparison between single-row and double-row rotator cuff repair: a biomechanical study.

    Science.gov (United States)

    Milano, Giuseppe; Grasso, Andrea; Zarelli, Donatella; Deriu, Laura; Cillo, Mario; Fabbriciani, Carlo

    2008-01-01

    The aim of this study was to compare the mechanical behavior under cyclic loading test of single-row and double-row rotator cuff repair with suture anchors in an ex-vivo animal model. For the present study, 50 fresh porcine shoulders were used. On each shoulder, a crescent-shaped full-thickness tear of the infraspinatus was performed. Width of the tendon tear was 2 cm. The lesion was repaired using metal suture anchors. Shoulders were divided in four groups, according the type of repair: single-row tension-free repair (Group 1); single-row tension repair (Group 2); double-row tension-free repair (Group 3); double-row tension repair (Group 4); and a control group. Specimens were subjected to a cyclic loading test. Number of cycles at 5 mm of elongation and at failure, and total elongation were calculated. Single-row tension repair showed significantly poorest results for all the variables considered, when compared with the other groups. Regarding the mean number of cycles at 5 mm of elongation and at failure, there was a nonsignificant difference between Groups 3 and 4, and both of them were significantly greater than Group 1. For mean total elongation, the difference between Groups 1, 3, and 4 was not significant, but all of them were significantly lower than the control group. A single-row repair is particularly weak when performed under tension. Double-row repair is significantly more resistant to cyclic displacement than single-row repair in both tension-free and tension repair. Double-row repair technique can be primarily considered for large, unstable rotator cuff tears to improve mechanical strength of primary fixation of tendons to bone.

  2. Narrow beam neutron dosimetry.

    Science.gov (United States)

    Ferenci, M Sutton

    2004-01-01

    Organ and effective doses have been estimated for male and female anthropomorphic mathematical models exposed to monoenergetic narrow beams of neutrons with energies from 10(-11) to 1000 MeV. Calculations were performed for anterior-posterior, posterior-anterior, left-lateral and right-lateral irradiation geometries. The beam diameter used in the calculations was 7.62 cm and the phantoms were irradiated at a height of 1 m above the ground. This geometry was chosen to simulate an accidental scenario (a worker walking through the beam) at Flight Path 30 Left (FP30L) of the Weapons Neutron Research (WNR) Facility at Los Alamos National Laboratory. The calculations were carried out using the Monte Carlo transport code MCNPX 2.5c.

  3. Effects of planting density and bearing-branch composition on the yield of sweet cherry [Prunus avium] grown by hedge-row training

    International Nuclear Information System (INIS)

    Tomita, A.; Shinya, K.; Watanabe, K.; Inomata, M.

    2008-01-01

    To improve the yield of sweet cherries (Prunus avium L.) grown by hedge-row training, the following two methods were compared: increased numbers of spurs and bouquet spurs to improve the spur composition and narrowed row intervals to increase planting density. To develop spurs and bouquet spurs, 30 cm long branches were positioned at 30 cm intervals on lateral branches in addition to the conventional spur development from 5 cm current shoots. Although this measure decreased the number of bouquet spurs, it increased the total number of spurs including the conventional short spurs to improve the yield to 1,024 kg/10a from 557 kg/10a using conventional hedge-row training. However, this method decreased solar radiation in the tree crowns thereby lowering fruit quality. In contrast, increasing planting density from 3-m intervals to 2- or 1.5-m intervals did not affect fruit quality. Moreover, in contrast to a yield of 588 kg/10a when row intervals were 3 m, the row intervals narrowed to 2 m and 1.5 m improved the yield to 881 kg/10a and 1,101 kg/10a, respectively. The above results show that decreasing row intervals is an effective method for increasing the yield of sweet cherries grown by hedge-row training without lowering fruit quality

  4. Outcomes of single-row and double-row arthroscopic rotator cuff repair: a systematic review.

    Science.gov (United States)

    Saridakis, Paul; Jones, Grant

    2010-03-01

    Arthroscopic rotator cuff repair is a common procedure that is gaining wide acceptance among orthopaedic surgeons because it is less invasive than open repair techniques. However, there is little consensus on whether to employ single-row or double-row fixation. The purpose of the present study was to systematically review the English-language literature to see if there is a difference between single-row and double-row fixation techniques in terms of clinical outcomes and radiographic healing. PubMed, the Cochrane Central Register of Controlled Trials, and EMBASE were reviewed with the terms "arthroscopic rotator cuff," "single row repair," and "double row repair." The inclusion criteria were a level of evidence of III (or better), an in vivo human clinical study on arthroscopic rotator cuff repair, and direct comparison of single-row and double-row fixation. Excluded were technique reports, review articles, biomechanical studies, and studies with no direct comparison of arthroscopic rotator cuff repair techniques. On the basis of these criteria, ten articles were found, and a review of the full-text articles identified six articles for final review. Data regarding demographic characteristics, rotator cuff pathology, surgical techniques, biases, sample sizes, postoperative rehabilitation regimens, American Shoulder and Elbow Surgeons scores, University of California at Los Angeles scores, Constant scores, and the prevalence of recurrent defects noted on radiographic studies were extracted. Confidence intervals were then calculated for the American Shoulder and Elbow Surgeons, University of California at Los Angeles, and Constant scores. Quality appraisal was performed by the two authors to identify biases. There was no significant difference between the single-row and double-row groups within each study in terms of postoperative clinical outcomes. However, one study divided each of the groups into patients with small-to-medium tears ( or = 3 cm in length), and the

  5. Monitoring of performance and training in rowing.

    Science.gov (United States)

    Mäestu, Jarek; Jürimäe, Jaak; Jürimäe, Toivo

    2005-01-01

    Rowing is a strength-endurance type of sport and competition performance depends on factors such as aerobic and anaerobic power, physical power, rowing technique and tactics. Therefore, a rower has to develop several capacities in order to be successful and a valid testing battery of a rower has to include parameters that are highly related to rowing performance. Endurance training is the mainstay in rowing. For the 2000 m race, power training at high velocities should be preferred to resistance training at low velocities in order to train more specifically during the off-season. The specific training of the international rower has to be approximately 70% of the whole training time. Several studies have reported different biochemical parameters for monitoring the training of rowers. There is some evidence that plasma leptin is more sensitive to training volume changes than specific stress hormones (e.g. cortisol, testosterone, growth hormone). In rowing, the stress hormone reactions to training volume and/or intensity changes are controversial. The Recovery-Stress Questionnaire for Athletes measures both stress and recovery, and may therefore be more effective than the previously used Borg ratio scale or the Profile of Mood States, which both focus mainly on the stress component. In the future, probably the most effective way to evaluate the training of rowers is to monitor both stress and recovery components at the same time, using both psychometric data together with the biochemical and performance parameters.

  6. Meta-analysis of Clinical and Radiographic Outcomes After Arthroscopic Single-Row Versus Double-Row Rotator Cuff Repair

    OpenAIRE

    Perser, Karen; Godfrey, David; Bisson, Leslie

    2011-01-01

    Context: Double-row rotator cuff repair methods have improved biomechanical performance when compared with single-row repairs. Objective: To review clinical outcomes of single-row versus double-row rotator cuff repair with the hypothesis that double-row rotator cuff repair will result in better clinical and radiographic outcomes. Data Sources: Published literature from January 1980 to April 2010. Key terms included rotator cuff, prospective studies, outcomes, and suture techniques. Study Sele...

  7. Biomechanical evaluation of a single-row versus double-row repair for complete subscapularis tears.

    Science.gov (United States)

    Wellmann, Mathias; Wiebringhaus, Philipp; Lodde, Ina; Waizy, Hazibullah; Becher, Christoph; Raschke, Michael J; Petersen, Wolf

    2009-12-01

    The purpose of the study was to compare a single-row repair and a double-row repair technique for the specific characteristics of a complete subscapularis lesion. Ten pairs of human cadaveric shoulder human shoulder specimens were tested for stiffness and ultimate tensile strength of the intact tendons in a load to failure protocol. After a complete subscapularis tear was provoked, the specimens were assigned to two treatment groups: single-row repair (1) and a double-row repair using a "suture bridge" technique (2). After repair cyclic loading a subsequent load to failure protocol was performed to determine the ultimate tensile load, the stiffness and the elongation behaviour of the reconstructions. The intact subscapularis tendons had a mean stiffness of 115 N/mm and a mean ultimate load of 720 N. The predominant failure mode of the intact tendons was a tear at the humeral insertion site (65%). The double-row technique restored 48% of the ultimate load of the intact tendons (332 N), while the single-row technique revealed a significantly lower ultimate load of 244 N (P = 0.001). In terms of the stiffness, the double-row technique showed a mean stiffness of 81 N/mm which is significantly higher compared to the stiffness of the single-row repairs of 55 N/mm (P = 0.001). The double-row technique has been shown to be stronger and stiffer when compared to a conventional single-row repair. Therefore, this technique is recommended from a biomechanical point of view irrespectively if performed by an open or arthroscopic approach.

  8. Optical RAM row access using WDM-enabled all-passive row/column decoders

    Science.gov (United States)

    Papaioannou, Sotirios; Alexoudi, Theoni; Kanellos, George T.; Miliou, Amalia; Pleros, Nikos

    2014-03-01

    Towards achieving a functional RAM organization that reaps the advantages offered by optical technology, a complete set of optical peripheral modules, namely the Row (RD) and Column Decoder (CD) units, is required. In this perspective, we demonstrate an all-passive 2×4 optical RAM RD with row access operation and subsequent all-passive column decoding to control the access of WDM-formatted words in optical RAM rows. The 2×4 RD exploits a WDM-formatted 2-bit-long memory WordLine address along with its complementary value, all of them encoded on four different wavelengths and broadcasted to all RAM rows. The RD relies on an all-passive wavelength-selective filtering matrix (λ-matrix) that ensures a logical `0' output only at the selected RAM row. Subsequently, the RD output of each row drives the respective SOA-MZI-based Row Access Gate (AG) to grant/block the entry of the incoming data words to the whole memory row. In case of a selected row, the data word exits the row AG and enters the respective CD that relies on an allpassive wavelength-selective Arrayed Waveguide Grating (AWG) for decoding the word bits into their individual columns. Both RD and CD procedures are carried out without requiring any active devices, assuming that the memory address and data word bits as well as their inverted values will be available in their optical form by the CPU interface. Proof-of-concept experimental verification exploiting cascaded pairs of AWGs as the λ-matrix is demonstrated at 10Gb/s, providing error-free operation with a peak power penalty lower than 0.2dB for all optical word channels.

  9. Machine learning analysis of binaural rowing sounds

    DEFF Research Database (Denmark)

    Johard, Leonard; Ruffaldi, Emanuele; Hoffmann, Pablo F.

    2011-01-01

    Techniques for machine hearing are increasing their potentiality due to new application domains. In this work we are addressing the analysis of rowing sounds in natural context for the purpose of supporting a training system based on virtual environments. This paper presents the acquisition metho...... methodology and the evaluation of different machine learning techniques for classifying rowing-sound data. We see that a combination of principal component analysis and shallow networks perform equally well as deep architectures, while being much faster to train.......Techniques for machine hearing are increasing their potentiality due to new application domains. In this work we are addressing the analysis of rowing sounds in natural context for the purpose of supporting a training system based on virtual environments. This paper presents the acquisition...

  10. Automatic crop row detection from UAV images

    DEFF Research Database (Denmark)

    Midtiby, Henrik; Rasmussen, Jesper

    are considered weeds. We have used a Sugar beet field as a case for evaluating the proposed crop detection method. The suggested image processing consists of: 1) locating vegetation regions in the image by thresholding the excess green image derived from the orig- inal image, 2) calculate the Hough transform......Images from Unmanned Aerial Vehicles can provide information about the weed distribution in fields. A direct way is to quantify the amount of vegetation present in different areas of the field. The limitation of this approach is that it includes both crops and weeds in the reported num- bers. To get...... of the segmented image 3) determine the dominating crop row direction by analysing output from the Hough transform and 4) use the found crop row direction to locate crop rows....

  11. Functional and structural outcomes of single-row versus double-row versus combined double-row and suture-bridge repair for rotator cuff tears.

    Science.gov (United States)

    Mihata, Teruhisa; Watanabe, Chisato; Fukunishi, Kunimoto; Ohue, Mutsumi; Tsujimura, Tomoyuki; Fujiwara, Kenta; Kinoshita, Mitsuo

    2011-10-01

    Although previous biomechanical research has demonstrated the superiority of the suture-bridge rotator cuff repair over double-row repair from a mechanical point of view, no articles have described the structural and functional outcomes of this type of procedure. The structural and functional outcomes after arthroscopic rotator cuff repair may be different between the single-row, double-row, and combined double-row and suture-bridge (compression double-row) techniques. Cohort study; Level of evidence, 3. There were 206 shoulders in 201 patients with full-thickness rotator cuff tears that underwent arthroscopic rotator cuff repair. Eleven patients were lost to follow-up. Sixty-five shoulders were repaired using the single-row, 23 shoulders using the double-row, and 107 shoulders using the compression double-row techniques. Clinical outcomes were evaluated at an average of 38.5 months (range, 24-74 months) after rotator cuff repair. Postoperative cuff integrity was determined using Sugaya's classification of magnetic resonance imaging (MRI). The retear rates after arthroscopic rotator cuff repair were 10.8%, 26.1%, and 4.7%, respectively, for the single-row, double-row, and compression double-row techniques. In the subcategory of large and massive rotator cuff tears, the retear rate in the compression double-row group (3 of 40 shoulders, 7.5%) was significantly less than those in the single-row group (5 of 8 shoulders, 62.5%, P row group (5 of 12 shoulders, 41.7%, P row and suture-bridge techniques, which had the lowest rate of postoperative retear, is an effective option for arthroscopic repair of the rotator cuff tendons because the postoperative functional outcome in patients with a retear is inferior to that without retear.

  12. Field sprayer for inter and intra-row weed control: performance and labor savings

    Directory of Open Access Journals (Sweden)

    J. Carballido

    2013-07-01

    Full Text Available Studies of new tools and methods for weed control have been motivated by increased consumer demand for organic produce, consumer and regulatory demands for a reduction in environmentally harmful herbicide use, and the decreased availability of farm workers willing to perform manual tasks, such as hand weeding. This study describes the performance of a new sprayer system for commercial production that integrates two herbicide applications in a single pass, selective herbicide (SH application in narrow bands over the crop row, and a non-selective herbicide (NSH application between crop rows. A real-time kinematic (RTK global positioning system (GPS was used for auto-guidance in seeding and spraying operations. Conventional broadcast SHs and experimental treatments were applied at a constant nominal speed of 5.5 km h-1 for comparison. Trials in commercial sugar beet fields demonstrated the following: (i average hand-weeding time can be reduced by 53% (ii the new sprayer system reduced SH use by 76%, and (iii sugar beet density did not change significantly during treatment. These results demonstrate the feasibility of using the new RTK-GPS controller sprayer system for differential and efficient herbicide application in inter- and intra-row zones in row crop production.

  13. Narrow, duplicated internal auditory canal

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, T. [Servico de Neurorradiologia, Hospital Garcia de Orta, Avenida Torrado da Silva, 2801-951, Almada (Portugal); Shayestehfar, B. [Department of Radiology, UCLA Oliveview School of Medicine, Los Angeles, California (United States); Lufkin, R. [Department of Radiology, UCLA School of Medicine, Los Angeles, California (United States)

    2003-05-01

    A narrow internal auditory canal (IAC) constitutes a relative contraindication to cochlear implantation because it is associated with aplasia or hypoplasia of the vestibulocochlear nerve or its cochlear branch. We report an unusual case of a narrow, duplicated IAC, divided by a bony septum into a superior relatively large portion and an inferior stenotic portion, in which we could identify only the facial nerve. This case adds support to the association between a narrow IAC and aplasia or hypoplasia of the vestibulocochlear nerve. The normal facial nerve argues against the hypothesis that the narrow IAC is the result of a primary bony defect which inhibits the growth of the vestibulocochlear nerve. (orig.)

  14. Influence of the narrow {111} planes on axial and planar ion channeling.

    Science.gov (United States)

    Motapothula, M; Dang, Z Y; Venkatesan, T; Breese, M B H; Rana, M A; Osman, A

    2012-05-11

    We report channeling patterns where clearly resolved effects of the narrow {111} planes are observed in axial and planar alignments for 2 MeV protons passing through a 55 nm [001] silicon membrane. At certain axes, such as and , the offset in atomic rows forming the narrow {111} planes results in shielding from the large potential at the wide {111} planes, producing a region of shallow, asymmetric potential from which axial channeling patterns have no plane of symmetry. At small tilts from such axes, different behavior is observed from the wide and narrow {111} planes. At planar alignment, distinctive channeling effects due to the narrow planes are observed. As a consequence of the shallow potential well at the narrow planes, incident protons suffer dechanneled trajectories which are excluded from channeling within the wide planes, resulting in an anomalously large scattered beam at {111} alignment.

  15. Narrow field electromagnetic sensor system and method

    International Nuclear Information System (INIS)

    McEwan, T.E.

    1996-01-01

    A narrow field electromagnetic sensor system and method of sensing a characteristic of an object provide the capability to realize a characteristic of an object such as density, thickness, or presence, for any desired coordinate position on the object. One application is imaging. The sensor can also be used as an obstruction detector or an electronic trip wire with a narrow field without the disadvantages of impaired performance when exposed to dirt, snow, rain, or sunlight. The sensor employs a transmitter for transmitting a sequence of electromagnetic signals in response to a transmit timing signal, a receiver for sampling only the initial direct RF path of the electromagnetic signal while excluding all other electromagnetic signals in response to a receive timing signal, and a signal processor for processing the sampled direct RF path electromagnetic signal and providing an indication of the characteristic of an object. Usually, the electromagnetic signal is a short RF burst and the obstruction must provide a substantially complete eclipse of the direct RF path. By employing time-of-flight techniques, a timing circuit controls the receiver to sample only the initial direct RF path of the electromagnetic signal while not sampling indirect path electromagnetic signals. The sensor system also incorporates circuitry for ultra-wideband spread spectrum operation that reduces interference to and from other RF services while allowing co-location of multiple electronic sensors without the need for frequency assignments. 12 figs

  16. Flexible frontiers for text division into rows

    Directory of Open Access Journals (Sweden)

    Dan L. Lacrămă

    2009-01-01

    Full Text Available This paper presents an original solution for flexible hand-written text division into rows. Unlike the standard procedure, the proposed method avoids the isolated characters extensions amputation and reduces the recognition error rate in the final stage.

  17. Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation.

    Science.gov (United States)

    Ma, C Benjamin; Comerford, Lyn; Wilson, Joseph; Puttlitz, Christian M

    2006-02-01

    Recent studies have shown that arthroscopic rotator cuff repairs can have higher rates of failure than do open repairs. Current methods of rotator cuff repair have been limited to single-row fixation of simple and horizontal stitches, which is very different from open repairs. The objective of this study was to compare the initial cyclic loading and load-to-failure properties of double-row fixation with those of three commonly used single-row techniques. Ten paired human supraspinatus tendons were split in half, yielding four tendons per cadaver. The bone mineral content at the greater tuberosity was assessed. Four stitch configurations (two-simple, massive cuff, arthroscopic Mason-Allen, and double-row fixation) were randomized and tested on each set of tendons. Specimens were cyclically loaded between 5 and 100 N at 0.25 Hz for fifty cycles and then loaded to failure under displacement control at 1 mm/sec. Conditioning elongation, peak-to-peak elongation, ultimate tensile load, and stiffness were measured with use of a three-dimensional tracking system and compared, and the failure type (suture or anchor pull-out) was recorded. No significant differences were found among the stitches with respect to conditioning elongation. The mean peak-to-peak elongation (and standard error of the mean) was significantly lower for the massive cuff (1.1 +/- 0.1 mm) and double-row stitches (1.1 +/- 0.1 mm) than for the arthroscopic Mason-Allen stitch (1.5 +/- 0.2 mm) (p row fixation (287 +/- 24 N) than for all of the single-row fixations (p row fixation had a significantly higher ultimate tensile load than the three types of single-row fixation stitches. Of the single-row fixations, the massive cuff stitch had cyclic and load-to-failure characteristics similar to the double-row fixation. Anterior repairs of the supraspinatus tendon had significantly stronger biomechanical behavior than posterior repairs.

  18. Danish Ultras

    DEFF Research Database (Denmark)

    Havelund, Jonas; Joern, Lise; Rasmussen, Kristian

    2012-01-01

    It is well documented that knowledge of supporter culture is crucial when assessing the risk of disorder at football matches and thereby ensuring a balanced approach by police and stewards (Stott & Pearson 2007). Both within Denmark and internationally, there is a weak understanding of risk suppo....... The article aims to create knowledge concerning ultra supporter culture with the purpose of gaining the information necessary for building differentiated and balanced action on the part of the police and security services....

  19. Extended abstract: Partial row projection methods

    Energy Technology Data Exchange (ETDEWEB)

    Bramley, R.; Lee, Y. [Indiana Univ., Bloomington, IN (United States)

    1996-12-31

    Accelerated row projection (RP) algorithms for solving linear systems Ax = b are a class of iterative methods which in theory converge for any nonsingular matrix. RP methods are by definition ones that require finding the orthogonal projection of vectors onto the null space of block rows of the matrix. The Kaczmarz form, considered here because it has a better spectrum for iterative methods, has an iteration matrix that is the product of such projectors. Because straightforward Kaczmarz method converges slowly for practical problems, typically an outer CG acceleration is applied. Definiteness, symmetry, or localization of the eigenvalues, of the coefficient matrix is not required. In spite of this robustness, work has generally been limited to structured systems such as block tridiagonal matrices because unlike many iterative solvers, RP methods cannot be implemented by simply supplying a matrix-vector multiplication routine. Finding the orthogonal projection of vectors onto the null space of block rows of the matrix in practice requires accessing the actual entries in the matrix. This report introduces a new partial RP algorithm which retains advantages of the RP methods.

  20. Flooding correlations in narrow channel

    International Nuclear Information System (INIS)

    Kim, S. H.; Baek, W. P.; Chang, S. H.

    1999-01-01

    Heat transfer in narrow gap is considered as important phenomena in severe accidents in nuclear power plants. Also in heat removal of electric chip. Critical heat flux(CHF) in narrow gap limits the maximum heat transfer rate in narrow channel. In case of closed bottom channel, flooding limited CHF occurrence is observed. Flooding correlations will be helpful to predict the CHF in closed bottom channel. In present study, flooding data for narrow channel geometry were collected and the work to recognize the effect of the span, w and gap size, s were performed. And new flooding correlations were suggested for high-aspect-ratio geometry. Also, flooding correlation was applied to flooding limited CHF data

  1. Narrow n anti n resonances

    International Nuclear Information System (INIS)

    Bogdanova, L.N.; Dalkarov, O.D.; Kerbikov, B.O.; Shapiro, I.S.

    1975-01-01

    The present status of the problem of quasinuclear states in systems of nucleons and antinucleons is reviewed. The theoretical predictions are compared with experimental data on narrow meson resonances near N anti N threshold which appeared in 1971-74

  2. Meta-analysis of Clinical and Radiographic Outcomes After Arthroscopic Single-Row Versus Double-Row Rotator Cuff Repair.

    Science.gov (United States)

    Perser, Karen; Godfrey, David; Bisson, Leslie

    2011-05-01

    Double-row rotator cuff repair methods have improved biomechanical performance when compared with single-row repairs. To review clinical outcomes of single-row versus double-row rotator cuff repair with the hypothesis that double-row rotator cuff repair will result in better clinical and radiographic outcomes. Published literature from January 1980 to April 2010. Key terms included rotator cuff, prospective studies, outcomes, and suture techniques. The literature was systematically searched, and 5 level I and II studies were found comparing clinical outcomes of single-row and double-row rotator cuff repair. Coleman methodology scores were calculated for each article. Meta-analysis was performed, with treatment effect between single row and double row for clinical outcomes and with odds ratios for radiographic results. The sample size necessary to detect a given difference in clinical outcome between the 2 methods was calculated. Three level I studies had Coleman scores of 80, 74, and 81, and two level II studies had scores of 78 and 73. There were 156 patients with single-row repairs and 147 patients with double-row repairs, both with an average follow-up of 23 months (range, 12-40 months). Double-row repairs resulted in a greater treatment effect for each validated outcome measure in 4 studies, but the differences were not clinically or statistically significant (range, 0.4-2.2 points; 95% confidence interval, -0.19, 4.68 points). Double-row repairs had better radiographic results, but the differences were also not statistically significant (P = 0.13). Two studies had adequate power to detect a 10-point difference between repair methods using the Constant score, and 1 study had power to detect a 5-point difference using the UCLA (University of California, Los Angeles) score. Double-row rotator cuff repair does not show a statistically significant improvement in clinical outcome or radiographic healing with short-term follow-up.

  3. Multidetector-row CT: economics and workflow

    International Nuclear Information System (INIS)

    Pottala, K.M.; Kalra, M.K.; Saini, S.; Ouellette, K.; Sahani, D.; Thrall, J.H.

    2005-01-01

    With rapid evolution of multidetector-row CT (MDCT) technology and applications, several factors such ad technology upgrade and turf battles for sharing cost and profitability affect MDCT workflow and economics. MDCT workflow optimization can enhance productivity and reduce unit costs as well as increase profitability, in spite of decrease in reimbursement rates. Strategies for workflow management include standardization, automation, and constant assessment of various steps involved in MDCT operations. In this review article, we describe issues related to MDCT economics and workflow. (orig.)

  4. Single-row versus double-row arthroscopic rotator cuff repair in small- to medium-sized tears.

    Science.gov (United States)

    Aydin, Nuri; Kocaoglu, Baris; Guven, Osman

    2010-07-01

    Double-row rotator cuff repair leads to superior cuff integrity and clinical results compared with single-row repair. The study enrolled 68 patients with a full-thickness rotator cuff tear who were divided into 2 groups of 34 patients according to repair technique. The patients were followed-up for at least 2 years. The results were evaluated by Constant score. Despite the biomechanical studies and cadaver studies that proved the superiority of double-row fixation over single-row fixation, our clinical results show no difference in functional outcome between the two methods. It is evident that double-row repair is more technically demanding, expensive, and time-consuming than single-row repair, without providing a significant improvement in clinical results. Comparison between groups did not show significant differences. At the final follow-up, the Constant score was 82.2 in the single-row group and 78.8 in the double-row group. Functional outcome was improved in both groups after surgery, but the difference between the 2 groups was not significant. At long-term follow-up, arthroscopic rotator cuff repair with the double-row technique showed no significant difference in clinical outcome compared with single-row repair in small to medium tears. 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  5. A biomechanical comparison of 2 technical variations of double-row rotator cuff fixation: the importance of medial row knots.

    Science.gov (United States)

    Busfield, Benjamin T; Glousman, Ronald E; McGarry, Michelle H; Tibone, James E; Lee, Thay Q

    2008-05-01

    Previous studies have shown comparable biomechanical properties of double-row fixation versus double-row fixation with a knotless lateral row. SutureBridge is a construct that secures the cuff with medial row mattress suture anchors and knotless lateral row fixation of the medial suture ends. Recent completely knotless constructs may lead to lesser clinical outcomes if the construct properties are compromised from lack of suture knots. A completely knotless construct without medial row knots will compromise the biomechanical properties in both cyclic and failure-testing parameters. Controlled laboratory study. Six matched pairs of cadaveric shoulders were randomized to 2 groups of double row fixation with SutureBridge: group 1 with medial row knots, and group 2 without medial row knots. The specimens were placed in a materials test system at 30 degrees of abduction. Cyclic testing to 180 N at 1 mm/sec for 30 cycles was performed, followed by tensile testing to failure at 1 mm/sec. Data included cyclic and failure data from the materials test system and gap data using a video digitizing system. All data from paired specimens were compared using paired Student t tests. Group 1 had a statistically significant difference (P row failure, whereas all group 1 specimens failed at the clamp. Although lateral row knotless fixation has been shown not to sacrifice structural integrity of this construct, the addition of a knotless medial row compromises the construct leading to greater gapping and failure at lower loads. This may raise concerns regarding recently marketed completely knotless double row constructs.

  6. NUMERICAL MODEL APPLICATION IN ROWING SIMULATOR DESIGN

    Directory of Open Access Journals (Sweden)

    Petr Chmátal

    2016-04-01

    Full Text Available The aim of the research was to carry out a hydraulic design of rowing/sculling and paddling simulator. Nowadays there are two main approaches in the simulator design. The first one includes a static water with no artificial movement and counts on specially cut oars to provide the same resistance in the water. The second approach, on the other hand uses pumps or similar devices to force the water to circulate but both of the designs share many problems. Such problems are affecting already built facilities and can be summarized as unrealistic feeling, unwanted turbulent flow and bad velocity profile. Therefore, the goal was to design a new rowing simulator that would provide nature-like conditions for the racers and provide an unmatched experience. In order to accomplish this challenge, it was decided to use in-depth numerical modeling to solve the hydraulic problems. The general measures for the design were taken in accordance with space availability of the simulator ́s housing. The entire research was coordinated with other stages of the construction using BIM. The detailed geometry was designed using a numerical model in Ansys Fluent and parametric auto-optimization tools which led to minimum negative hydraulic phenomena and decreased investment and operational costs due to the decreased hydraulic losses in the system.

  7. Optically trapped atomic resonant devices for narrow linewidth spectral imaging

    Science.gov (United States)

    Qian, Lipeng

    This thesis focuses on the development of atomic resonant devices for spectroscopic applications. The primary emphasis is on the imaging properties of optically thick atomic resonant fluorescent filters and their applications. In addition, this thesis presents a new concept for producing very narrow linewidth light as from an atomic vapor lamp pumped by a nanosecond pulse system. This research was motivated by application for missile warning system, and presents an innovative approach to a wide angle, ultra narrow linewidth imaging filter using a potassium vapor cell. The approach is to image onto and collect the fluorescent photons emitted from the surface of an optically thick potassium vapor cell, generating a 2 GHz pass-band imaging filter. This linewidth is narrow enough to fall within a Fraunhefer dark zone in the solar spectrum, thus make the detection solar blind. Experiments are conducted to measure the absorption line shape of the potassium resonant filter, the quantum efficiency of the fluorescent behavior, and the resolution of the fluorescent image. Fluorescent images with different spatial frequency components are analyzed by using a discrete Fourier transform, and the imaging capability of the fluorescent filter is described by its Modulation Transfer Function. For the detection of radiation that is spectrally broader than the linewidth of the potassium imaging filter, the fluorescent image is seen to be blurred by diffuse fluorescence from the slightly off resonant photons. To correct this, an ultra-thin potassium imaging filter is developed and characterized. The imaging property of the ultra-thin potassium imaging cell is tested with a potassium seeded flame, yielding a resolution image of ˜ 20 lines per mm. The physics behind the atomic resonant fluorescent filter is radiation trapping. The diffusion process of the resonant photons trapped in the atomic vapor is theoretically described in this thesis. A Monte Carlo method is used to simulate the

  8. The cost-effectiveness of single-row compared with double-row arthroscopic rotator cuff repair.

    Science.gov (United States)

    Genuario, James W; Donegan, Ryan P; Hamman, Daniel; Bell, John-Erik; Boublik, Martin; Schlegel, Theodore; Tosteson, Anna N A

    2012-08-01

    Interest in double-row techniques for arthroscopic rotator cuff repair has increased over the last several years, presumably because of a combination of literature demonstrating superior biomechanical characteristics and recent improvements in instrumentation and technique. As a result of the increasing focus on value-based health-care delivery, orthopaedic surgeons must understand the cost implications of this practice. The purpose of this study was to examine the cost-effectiveness of double-row arthroscopic rotator cuff repair compared with traditional single-row repair. A decision-analytic model was constructed to assess the cost-effectiveness of double-row arthroscopic rotator cuff repair compared with single-row repair on the basis of the cost per quality-adjusted life year gained. Two cohorts of patients (one with a tear of row compared with single-row arthroscopic rotator cuff repair was $571,500 for rotator cuff tears of row repair was less than $287 for small or moderate tears and less than $352 for large or massive tears compared with the cost of single-row repair, then double-row repair would represent a cost-effective surgical alternative. On the basis of currently available data, double-row rotator cuff repair is not cost-effective for any size rotator cuff tears. However, variability in the values for costs and probability of retear can have a profound effect on the results of the model and may create an environment in which double-row repair becomes the more cost-effective surgical option. The identification of the threshold values in this study may help surgeons to determine the most cost-effective treatment.

  9. Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair.

    Science.gov (United States)

    Kim, David H; Elattrache, Neal S; Tibone, James E; Jun, Bong-Jae; DeLaMora, Sergai N; Kvitne, Ronald S; Lee, Thay Q

    2006-03-01

    Reestablishment of the native footprint during rotator cuff repair has been suggested as an important criterion for optimizing healing potential and fixation strength. A double-row rotator cuff footprint repair will demonstrate superior biomechanical properties compared with a single-row repair. Controlled laboratory study. In 9 matched pairs of fresh-frozen cadaveric shoulders, the supraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique: 2 medial anchors with horizontal mattress sutures and 2 lateral anchors with simple sutures. The tendon from the contralateral shoulder was repaired using a single lateral row of 2 anchors with simple sutures. Each specimen underwent cyclic loading from 10 to 180 N for 200 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a video digitizing system; stiffness and failure load were determined from testing machine data. Gap formation for the double-row repair was significantly smaller (P row repair for the first cycle (1.67 +/- 0.75 mm vs 3.10 +/- 1.67 mm, respectively) and the last cycle (3.58 +/- 2.59 mm vs 7.64 +/- 3.74 mm, respectively). The initial strain over the footprint area for the double-row repair was nearly one third (P row repair. Adding a medial row of anchors increased the stiffness of the repair by 46% and the ultimate failure load by 48% (P row repair improved initial strength and stiffness and decreased gap formation and strain over the footprint when compared with a single-row repair. To achieve maximal initial fixation strength and minimal gap formation for rotator cuff repair, reconstructing the footprint attachment with 2 rows of suture anchors should be considered.

  10. Interactive motion tracing for Rowing Training

    DEFF Research Database (Denmark)

    Dai, Zheng

    2011-01-01

    This paper studies motion tracking and team coordination for the training of rowers. The design research is drawn upon the division of contribution between the designers input and the user input in a design process. We built a training system that can record and show the action of a rower’s hand....... Designer proposed solutions for both a fundamental problem and a very advanced problem. Users guided the design direction, and spoke what they expected or what they disliked. As the result, our design provided a real-time recording tool for rowers and coaches to discuss and analyze the motion. The coach...... can correct the path immediately and save the corrected path for the rower to try to imitate and train. The members in a rowing team train with the same path from to coordinate and synchronize their actions for the best performance. The training system was developed through a user-centered design...

  11. Resource-saving inter-row cultivator

    Directory of Open Access Journals (Sweden)

    N. E. Rudenko

    2017-01-01

    Full Text Available Inter-row cultivators have some shortcomings: design is complicated due to placing on each section of a 4-unit (parallelogram suspension of working tools; as the copying means use wheels which are mounted at distance from working tools, in other vertical plane, and have negative effect on variability of tillage depth; working tools are V-shaped hoes with a crumbling angle not more than 16 degrees. In the operation course the parts of a leg and a hoe, moving in the soil, raise it and throw to the side, creating not aligned surface grooves are formed, imposed moist soil. These processes are exacerbated by increasing the operating speed of the cultivator. The authors offered a resource-saving inter-row cultivator with a radial suspension of working tools. A flat plate spring was used as a beam. This simplifies the design, eliminates the horizontal oscillations of the working tools, provides a constant pressing them in the process. The working tool in the form of a flat lancet plowshares with a spiral fixed on the leg was designed. Operating width of a ploughshare is of 420 mm, thickness equals 4 (5 mm. The spiral with a diameter of 50 mm is made of a carbon spring wire with a diameter of 2-3 mm. One hoe is set instead of three-five tines on each section, that significantly reduces material consumption. A plough share with a spiral form the swinging-loosening element that provides creating a fine lumpy topsoil. The ploughshare performs the copying functions therefore the additional copying wheels are not required. Tests showed that the new working tool of a cultivator allows to operate qualitatively at a speed up to 14-18 km/h.

  12. Effect of BMI on Knee Joint Torques in Ergometer Rowing

    NARCIS (Netherlands)

    Roemer, Karen; Hortobagyi, Tibor; Richter, Chris; Munoz-Maldonado, Yolanda; Hamilton, Stephanie

    2013-01-01

    Although an authoritative panel recommended the use of ergometer rowing as a non-weight-bearing form of exercise for obese adults, the biomechanical characterization of ergometer rowing is strikingly absent. We examined the interaction between body mass index (BMI) relative to the lower extremity

  13. Rows of Dislocation Loops in Aluminium Irradiated by Aluminium Ions

    DEFF Research Database (Denmark)

    Henriksen, L.; Johansen, A.; Koch, J.

    1967-01-01

    Single-crystal aluminium specimens, irradiated with 50-keV aluminium ions, contain dislocation loops that are arranged in regular rows along <110 > directions. ©1967 The American Institute of Physics......Single-crystal aluminium specimens, irradiated with 50-keV aluminium ions, contain dislocation loops that are arranged in regular rows along directions. ©1967 The American Institute of Physics...

  14. A vision based row detection system for sugar beet

    NARCIS (Netherlands)

    Bakker, T.; Wouters, H.; Asselt, van C.J.; Bontsema, J.; Tang, L.; Müller, J.; Straten, van G.

    2008-01-01

    One way of guiding autonomous vehicles through the field is using a vision based row detection system. A new approach for row recognition is presented which is based on grey-scale Hough transform on intelligently merged images resulting in a considerable improvement of the speed of image processing.

  15. Instability characteristics of fluidelastic instability of tube rows in crossflow

    International Nuclear Information System (INIS)

    Chen, S.S.; Jendrzejczyk, J.A.

    1986-04-01

    An experimental study is reported to investigate the jump phenomenon in critical flow velocities for tube rows with different pitch-to-diameter ratios and the excited and intrinsic instabilities for a tube row with a pitch-to-diameter ratio of 1.75. The experimental data provide additional insights into the instability phenomena of tube arrays in crossflow. 9 refs., 10 figs

  16. Analysis of Indoor Rowing Motion using Wearable Inertial Sensors

    NARCIS (Netherlands)

    Bosch, S.; Shoaib, M.; Geerlings, Stephen; Buit, Lennart; Meratnia, Nirvana; Havinga, Paul J.M.

    2015-01-01

    In this exploratory work the motion of rowers is analyzed while rowing on a rowing machine. This is performed using inertial sensors that measure the orientation at several positions on the body. Using these measurements, this work provides a preliminary analysis of the differences between

  17. QSOs with narrow emission lines

    International Nuclear Information System (INIS)

    Baldwin, J.A.; Mcmahon, R.; Hazard, C.; Williams, R.E.

    1988-01-01

    Observations of two new high-redshift, narrow-lined QSOs (NLQSOs) are presented and discussed together with observations of similar objects reported in the literature. Gravitational lensing is ruled out as a possible means of amplifying the luminosity for one of these objects. It is found that the NLQSOs have broad bases on their emission lines as well as the prominent narrow cores which define this class. Thus, these are not pole-on QSOs. The FWHM of the emission lines fits onto the smoothly falling tail of the lower end of the line-width distribution for complete QSO samples. The equivalent widths of the combined broad and narrow components of the lines are normal for QSOs of the luminosity range under study. However, the NLQSOs do show ionization differences from broader-lined QSOs; most significant, the semiforbidden C III/C IV intensity ratio is unusually low. The N/C abundance ratio in these objects is found to be normal; the Al/C abundance ratio may be quite high. 38 references

  18. Improving Spectral Results Using Row-by-Row Fourier Transform of Spatial Heterodyne Raman Spectrometer Interferogram.

    Science.gov (United States)

    Barnett, Patrick D; Strange, K Alicia; Angel, S Michael

    2017-06-01

    This work describes a method of applying the Fourier transform to the two-dimensional Fizeau fringe patterns generated by the spatial heterodyne Raman spectrometer (SHRS), a dispersive interferometer, to correct the effects of certain types of optical alignment errors. In the SHRS, certain types of optical misalignments result in wavelength-dependent and wavelength-independent rotations of the fringe pattern on the detector. We describe here a simple correction technique that can be used in post-processing, by applying the Fourier transform in a row-by-row manner. This allows the user to be more forgiving of fringe alignment and allows for a reduction in the mechanical complexity of the SHRS.

  19. Development of Functional Electrical Stimulation Rowing: The Rowstim Series.

    Science.gov (United States)

    Andrews, Brian; Gibbons, Robin; Wheeler, Garry

    2017-11-01

    Potentially, functional electrical stimulation (FES)-assisted exercise may have an important therapeutic role in reducing comorbidities associated with spinal cord injury (SCI). Here, we present an overview of these secondary life-threatening conditions, discuss the rationale behind the development of a hybrid exercise called FES rowing, and describe our experience in developing FES rowing technology. FES rowing and sculling are unique forms of adaptive rowing for those with SCI. The paralyzed leg musculature is activated by multiple channels of electrical pulses delivered via self-adhesive electrodes attached to the skin. The stimulated muscle contractions are synchronized with voluntary rowing movements of the upper limbs. A range of steady-state FES rowing exercise intensities have been demonstrated from 15.2 ± 1.8 mL/kg/min in tetraplegia to 22.9 ±7.1 mL/kg/min in paraplegia. We expect that such high levels may help some to achieve significant reductions in the risks to their health, particularly where a dose-response relationship exists as is the case for cardiovascular disease and Type II diabetes. Furthermore, preliminary results suggest that cyclical forces more than 1.5 times body weight are imposed on the leg long bones which may help to reduce the risk of fragility fractures. We have demonstrated the feasibility of FES rowing on land and water using adapted rowing technology that includes; a fixed stretcher indoor ergometer (adapted Concept 2, Model E), a floating stretcher indoor ergometer (adapted Concept 2 Dynamic), a turbine powered water rowing tank, a custom hydraulic sculling simulator and a single scull (adapted Alden 16). This has involved volunteers with paraplegia and tetraplegia with SCI ranging from C4 to T12 AIS A using at least 4-channels of surface electrical stimulation. FES rowers, with SCI, have competed alongside non-SCI rowers over the Olympic distance of 2000 m at the British Indoor Rowing Championships in 2004, 2005, and 2006

  20. An aerial radiological survey of the Yankee Rowe Nuclear Power Station and surrounding area, Rowe, Massachusetts

    International Nuclear Information System (INIS)

    Boyns, P.K.; Bluitt, C.M.

    1993-09-01

    An aerial radiological survey was conducted over the Yankee Rowe Nuclear Power Station in Rowe, Massachusetts, during the period August 17--24, 1989. The survey was conducted at an altitude of 300 feet (91 meters) over an 87-square-mile (225-square-kilometer) area centered on the power station. The purpose of the survey was to document the terrestrial gamma radiation environment of the Yankee Rowe Power Station and the surrounding area. The results of the aerial survey are reported as inferred gamma radiation exposure rates at 1 meter above ground level in the form of a contour map. Outside the plant boundary, exposure rates were found to vary between 6 and 10 microroentgens per hour (μR/h) and were attributed to naturally-occurring uranium, thorium, and radioactive potassium gamma emitters. The aerial data were compared to ground-based ''benchmark'' exposure rate measurements and radionuclide assays of soil samples obtained within the survey boundary. The ground-based measurements were found to be in good agreement with those inferred from the aerial measuring system

  1. Optimization of Inter-Row Spacing and Nitrogen Rate for the Application of Vision Guided Inter-Row weeding in Organic Spring Cereals

    DEFF Research Database (Denmark)

    Melander, Bo; Green, O.; Znova, L.

    2016-01-01

    -row spacing and nitrogen rate on weed and crop growth. Results are reported from two years field experiments with spring barley and spring wheat. It was aimed to maintain a constant seed rate for all five row spacing studied (12.5, 15, 20, 25 and 30 cm), which gave a higher crop density in the rows...... with increasing row spacing. A denser intra-row crop stand would improve the suppression of surviving intra-row weeds and partly compensate for the more weed growth that wider row spacing would cause by allowing more light penetration into the crop canopy. It was found that maintaining the seed rate when...

  2. Effects of variable-row-spacing harvesting picker platform scraping plates on cotton fiber quality and quantity

    Directory of Open Access Journals (Sweden)

    Cíntia Michele de Campos Baraviera

    2017-06-01

    Full Text Available There have been increasing demands for high-quality cotton fibers that meet the textile industry quality standards. Concurrently, there have been efforts to reduce contaminants during harvesting to reduce harvesting costs. The goal of this research was to evaluate the efficiency of the picker platform with Variable-Row-Spacing (VRS for harvesting cotton in narrow rows, over two harvest seasons in two regions within the state of Mato Grosso, Brazil. In this study, how the presence vs. absence of scraping plates and variations in travel speed was related to quantifiable levels of impurities the harvested fibers was examined. The research was divided into three experiments (Exp. I, II, and III, using cotton varieties FM 975 WS, IMA 5672 B2 RF, and IMA 5675 B2 RF, with row spacing of 0.45 m. The experimental design was randomized blocks, in a 2 ? 3 factorial design, using the presence/absence of the plate and three speeds (0.61, 1.0, and 1.42 m·s-¹, with seven repetitions, totaling 42 experimental plots. The plot size was 108 m² (3.6 ? 30 m. The data were analyzed using the F test in ANOVA and the post-hoc Tukey test (p < 0.05. The results showed that scraping plates increased the number of stems and cones, and reduced the harvest efficiency of cotton planted in narrow rows in the region of Sorriso-MT during the 2013/2014 harvest. For the 2014/2015 harvest, the highest speed and the presence of the scraping plates increased the number of cones in the cotton samples. In the experiment conducted in Serra da Petrovina, the removal of the scraping plates decreased the amount of cones in the harvested cotton.

  3. Sun Ultra 5

    CERN Multimedia

    1998-01-01

    The Sun Ultra 5 is a 64-bit personal computer based on the UltraSPARC microprocessor line at a low price. The Ultra 5 has been declined in several variants: thus, some models have a processor with less cache memory to further decrease the price of the computer.

  4. Biomechanical determinants of elite rowing technique and performance.

    Science.gov (United States)

    Buckeridge, E M; Bull, A M J; McGregor, A H

    2015-04-01

    In rowing, the parameters of injury, performance, and technique are all interrelated and in dynamic equilibrium. Whilst rowing requires extreme physical strength and endurance, a high level of skill and technique is essential to enable an effective transfer of power through the rowing sequence. This study aimed to determine discrete aspects of rowing technique, which strongly influence foot force production and asymmetries at the foot-stretchers, as these are biomechanical parameters often associated with performance and injury risk. Twenty elite female rowers performed an incremental rowing test on an instrumented rowing ergometer, which measured force at the handle and foot-stretchers, while three-dimensional kinematic recordings of the ankle, knee, hip, and lumbar-pelvic joints were made. Multiple regression analyses identified hip kinematics as a key predictor of foot force output (R(2)  = 0.48), whereas knee and lumbar-pelvic kinematics were the main determinants in optimizing the horizontal foot force component (R(2)  = .41). Bilateral asymmetries of the foot-stretchers were also seen to significantly influence lumbar-pelvic kinematics (R(2)  = 0.43) and pelvic twisting (R(2)  = 0.32) during the rowing stroke. These results provide biomechanical evidence toward aspects of technique that can be modified to optimize force output and performance, which can be of direct benefit to coaches and athletes. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Laser linewidth narrowing using transient spectral hole burning

    Energy Technology Data Exchange (ETDEWEB)

    Thiel, Charles W.; Cone, Rufus L. [Department of Physics, Montana State University, Bozeman, MT 59715 (United States); Böttger, Thomas, E-mail: tbottger@usfca.edu [Department of Physics and Astronomy, 2130 Fulton Street, University of San Francisco, San Francisco, CA 94117 (United States)

    2014-08-01

    We demonstrate significant narrowing of laser linewidths by high optical density materials with inhomogeneously broadened absorption. As a laser propagates through the material, the nonlinear spectral hole burning process causes a progressive self-filtering of the laser spectrum, potentially reaching values less than the homogeneous linewidth. The transient spectral hole dynamically adjusts itself to the instantaneous frequency of the laser, passively suppressing laser phase noise and side modes over the entire material absorption bandwidth without the need for electronic or optical feedback to the laser. Wide bandwidth laser phase noise suppression was demonstrated using Er{sup 3+} doped Y{sub 2}SiO{sub 5} and LiNbO{sub 3} at 1.5 μm by employing time-delayed self-heterodyne detection of an external cavity diode laser to study the spectral narrowing effect. Our method is not restricted to any particular wavelength or laser system and is attractive for a range of applications where ultra-low phase noise sources are required. - Highlights: • We demonstrate significant laser linewidths narrowing by high optical density materials. • Nonlinear spectral hole burning causes progressive self-filtering of laser spectrum. • Filter dynamically adjusts itself to the instantaneous frequency of the laser. • Demonstrated at 1.5 μm in Er{sup 3+} doped Y{sub 2}SiO{sub 5} and LiNbO{sub 3}. • Linewidth filtering is not restricted to any particular wavelength or laser system.

  6. Koka: Programming with Row Polymorphic Effect Types

    Directory of Open Access Journals (Sweden)

    Daan Leijen

    2014-06-01

    Full Text Available We propose a programming model where effects are treated in a disciplined way, and where the potential side-effects of a function are apparent in its type signature. The type and effect of expressions can also be inferred automatically, and we describe a polymorphic type inference system based on Hindley-Milner style inference. A novel feature is that we support polymorphic effects through row-polymorphism using duplicate labels. Moreover, we show that our effects are not just syntactic labels but have a deep semantic connection to the program. For example, if an expression can be typed without an _exn_ effect, then it will never throw an unhandled exception. Similar to Haskell's `runST` we show how we can safely encapsulate stateful operations. Through the state effect, we can also safely combine state with let-polymorphism without needing either imperative type variables or a syntactic value restriction. Finally, our system is implemented fully in a new language called Koka and has been used successfully on various small to medium-sized sample programs ranging from a Markdown processor to a tier-splitted chat application. You can try out Koka live at www.rise4fun.com/koka/tutorial.

  7. ULTRA-LIGHTWEIGHT CEMENT

    International Nuclear Information System (INIS)

    Fred Sabins

    2001-01-01

    The objective of this project is to develop an improved ultra-lightweight cement using ultra-lightweight hollow glass spheres (ULHS). Work reported herein addresses Task 1: Assess Ultra-Lightweight Cementing Issues, Task 2: Review Russian Ultra-Lightweight Cement Literature, Task 3: Test Ultra-Lightweight Cements, and Task 8: Develop Field ULHS Cement Blending and Mixing Techniques. Results reported this quarter include: preliminary findings from a literature review focusing on problems associated with ultra-lightweight cements; summary of pertinent information from Russian ultra-lightweight cement literature review; laboratory tests comparing ULHS slurries to foamed slurries and sodium silicate slurries for two different applications; and initial laboratory studies with ULHS in preparation for a field job

  8. Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner

    OpenAIRE

    Kakinuma, Ryutaro; Moriyama, Noriyuki; Muramatsu, Yukio; Gomi, Shiho; Suzuki, Masahiro; Nagasawa, Hirobumi; Kusumoto, Masahiko; Aso, Tomohiko; Muramatsu, Yoshihisa; Tsuchida, Takaaki; Tsuta, Koji; Maeshima, Akiko Miyagi; Tochigi, Naobumi; Watanabe, Shun-ichi; Sugihara, Naoki

    2015-01-01

    Purpose: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. Materials and Methods: This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm × 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm × 16 or 0.5 mm × 64 detector-row CT scanner operating at 150 mAs. Images fr...

  9. Gross efficiency during rowing is not affected by stroke rate

    NARCIS (Netherlands)

    Hofmijster, M.J.; van Soest, A.J.; de Koning, J.J.

    2009-01-01

    Purpose: It has been suggested that the optimal stroke rate in rowing is partly determined by the stroke-rate dependence of internal power losses. This should be reflected in a stroke-rate dependency of gross efficiency (e

  10. A Spider That Lays Its Eggs in Rows

    Directory of Open Access Journals (Sweden)

    Robert L. Edwards

    2000-01-01

    Full Text Available The small (2.5-3.0 mm, colorful metine spider, Homalometa nigritarsis Simon 1897, Family Tetragnathidae, has previously been reported from northern Mexico, Panama and the southern islands of the Lesser Antilles (Levi 1986. In the rain forest of northeastern Puerto Rico it is most frequently found with webbing on the larger outer concave surfaces of pendulous leaves. H. nigritarsis typically makes a circular, relatively flat retreat within which the female deposits two parallel rows of naked eggs. The rows are produced at intervals; as one row hatches another replaces it shortly thereafter. Evidence of up to four generations of rows has been observed. Above the retreat, and closely aligned with it, the spider builds a nearly invisible, delicate orb web, typically from edge to edge of the leaf (Fig. 1a and b. While retaining the traditional orb-web, H. nigritarsis has adopted a unique habitat and set of life history features.

  11. BCB polymer based row-column addressed CMUT

    DEFF Research Database (Denmark)

    Havreland, Andreas Spandet; Ommen, Martin Lind; Silvestre, Chantal

    2017-01-01

    This paper presents an inexpensive, low temperature and rapid fabrication method for capacitive micromachined ultrasonic transducers (CMUT). The fabrication utilizes the bonding and dielectric properties of the photosensitive polymer Benzocyclobutene (BCB). A BCB based row-column addressed CMUT w...

  12. Coordination with railroads to facilitate acquisition of ROW

    Science.gov (United States)

    2012-06-01

    It has been observed by the Federal Highway Administration (FHWA) Office of Real Estate Services (HEPR) that there has been an emerging national trend for increasingly difficult and time consuming right-of-way (ROW) access agreements and acquisitions...

  13. Harvester Productivity for Row Thinning Loblolly Pine Plantations

    Science.gov (United States)

    James E. Granskog; Walter C. Anderson

    1980-01-01

    Tivo tree harvesters currently being used to thin southern pine plantations were evaluated to determine the effects of stand characteristics on machine productivity. Production rates for row thinning loblolly plantations are presented by stand age, site index, and stand density.

  14. Exploratory analysis on the binaural characteristics of the rowing sound

    Directory of Open Access Journals (Sweden)

    Fillipeschi Alessandro

    2011-12-01

    Full Text Available Differences between the signals captured at the entrances to the left and right ears are generally quantified by interaural time differences (ITDs, interaural level differences (ILDs and interaural crosscorrelation (IC. Here, we attempt to gain knowledge on the changes of these interaural parameters during rowing and to evaluate their potential as source of information to determine rowing expertise exclusively from acoustic signals.

  15. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT

    International Nuclear Information System (INIS)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U.

    2012-01-01

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI vol values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 ± 2.5 vs. 11.4 ± 1.4, p < 0.001; 14.2 ± 3.7 vs. 16.1 ± 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 ± 201.1 vs. 849.8 ± 90.9, p < 0,001; 504.4 ± 134.4 vs. 471.5 ± 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 ± 35.8 vs. 155.5 ± 12.3 (p < 0.001), thorax 427.4 ± 44.5 vs. 388.3 ± 57.5 (p < 0.001), abdomen 520.3 ± 50.2 vs. 490.8 ± 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 ± 2.6 (4-row MDCT) and 24.1 ± 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  16. Don't Rock the Boat : How Antiphase Crew Coordination Affects Rowing

    NARCIS (Netherlands)

    de Brouwer, Anouk J.; de Poel, Harjo J.; Hofmijster, Mathijs J.

    2013-01-01

    It is generally accepted that crew rowing requires perfect synchronization between the movements of the rowers. However, a long-standing and somewhat counterintuitive idea is that out-of-phase crew rowing might have benefits over in-phase (i.e., synchronous) rowing. In synchronous rowing, 5 to 6% of

  17. Ultra-fast framing camera tube

    Science.gov (United States)

    Kalibjian, Ralph

    1981-01-01

    An electronic framing camera tube features focal plane image dissection and synchronized restoration of the dissected electron line images to form two-dimensional framed images. Ultra-fast framing is performed by first streaking a two-dimensional electron image across a narrow slit, thereby dissecting the two-dimensional electron image into sequential electron line images. The dissected electron line images are then restored into a framed image by a restorer deflector operated synchronously with the dissector deflector. The number of framed images on the tube's viewing screen is equal to the number of dissecting slits in the tube. The distinguishing features of this ultra-fast framing camera tube are the focal plane dissecting slits, and the synchronously-operated restorer deflector which restores the dissected electron line images into a two-dimensional framed image. The framing camera tube can produce image frames having high spatial resolution of optical events in the sub-100 picosecond range.

  18. Narrow gap electronegative capacitive discharges

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, E.; Lieberman, M. A.; Lichtenberg, A. J. [Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California 94720 (United States)

    2013-10-15

    Narrow gap electronegative (EN) capacitive discharges are widely used in industry and have unique features not found in conventional discharges. In this paper, plasma parameters are determined over a range of decreasing gap length L from values for which an electropositive (EP) edge exists (2-region case) to smaller L-values for which the EN region connects directly to the sheath (1-region case). Parametric studies are performed at applied voltage V{sub rf}=500 V for pressures of 10, 25, 50, and 100 mTorr, and additionally at 50 mTorr for 1000 and 2000 V. Numerical results are given for a parallel plate oxygen discharge using a planar 1D3v (1 spatial dimension, 3 velocity components) particle-in-cell (PIC) code. New interesting phenomena are found for the case in which an EP edge does not exist. This 1-region case has not previously been investigated in detail, either numerically or analytically. In particular, attachment in the sheaths is important, and the central electron density n{sub e0} is depressed below the density n{sub esh} at the sheath edge. The sheath oscillations also extend into the EN core, creating an edge region lying within the sheath and not characterized by the standard diffusion in an EN plasma. An analytical model is developed using minimal inputs from the PIC results, and compared to the PIC results for a base case at V{sub rf}=500 V and 50 mTorr, showing good agreement. Selected comparisons are made at the other voltages and pressures. A self-consistent model is also developed and compared to the PIC results, giving reasonable agreement.

  19. Ultra-orthodox Jewish Women Go to Work

    Directory of Open Access Journals (Sweden)

    Foscarini, Giorgia

    2014-12-01

    Full Text Available In the last three decades the ultra-orthodox community in Israel has experienced great changes in its internal social functioning. More specifically, these developments were linked to the education of ultra-orthodox women. Through an accurate review of the existing literature and a series of in-depth interviews with Israeli scholars, rabbis, educators and women of the ultra-orthodox community in Jerusalem, it was found that the introduction of new vocational and academic training tracks in women's education, is gradually changing the internal social structure of the ultra-orthodox family and community. The main consequence is expressed in a renegotiation of gender roles within the ultra-orthodox community and in a subversion of the traditional patriarchal framework. As a result of their participation in the labor market and in higher education institutions, women are more and more exposed to the Israeli secular culture, introducing in the traditional and segregated ultra-orthodox community customs typically modern, narrowing the gap between the ultra-orthodox community and the mainstream Israeli society.

  20. Validated biomechanical model for efficiency and speed of rowing.

    Science.gov (United States)

    Pelz, Peter F; Vergé, Angela

    2014-10-17

    The speed of a competitive rowing crew depends on the number of crew members, their body mass, sex and the type of rowing-sweep rowing or sculling. The time-averaged speed is proportional to the rower's body mass to the 1/36th power, to the number of crew members to the 1/9th power and to the physiological efficiency (accounted for by the rower's sex) to the 1/3rd power. The quality of the rowing shell and propulsion system is captured by one dimensionless parameter that takes the mechanical efficiency, the shape and drag coefficient of the shell and the Froude propulsion efficiency into account. We derive the biomechanical equation for the speed of rowing by two independent methods and further validate it by successfully predicting race times. We derive the theoretical upper limit of the Froude propulsion efficiency for low viscous flows. This upper limit is shown to be a function solely of the velocity ratio of blade to boat speed (i.e., it is completely independent of the blade shape), a result that may also be of interest for other repetitive propulsion systems. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. 320-detector row CT coronary angiography in patients with arrhythmia

    International Nuclear Information System (INIS)

    Lu Li; Zhang Zhaoqi; Xu Lei; Yang Lin

    2011-01-01

    Objective: To evaluate the feasibility of CT coronary angiography (CTCA) in patients with arrhythmia using 320-detector row CT. Methods: Thirty-one patients with persistent atrial fibrillation and 8 patients with premature ventricular contraction were enrolled in this study. All patients underwent 320- detector row CTCA. CT image quality was evaluated with 4-point grading scale by two radiologists. Inter- observer agreement was evaluated by Kappa statistics. The radiation dose was calculated. Results: In total 510 coronary segments, 496 (97.2%) segments met diagnostic standard. The mean effective dose was (12.7±4.8) mSv in this study. There was a good agreement in image quality scoring between the two reviewers (Kappa = 0.72). Conclusion: 320-detector row CTCA is feasible in patients with atrial fibrillation and premature ventricular contraction. Arrhythmia may not be considered as a contraindication to CTCA. (authors)

  2. Nutrition and Supplements for Elite Open-Weight Rowing.

    Science.gov (United States)

    Boegman, Susan; Dziedzic, Christine E

    2016-01-01

    Competitive rowing events are raced over 2,000 m requiring athletes to have highly developed aerobic and anaerobic systems. Elite rowers therefore undertake training sessions focused on lactate tolerance, strength and power as well as aerobic and anaerobic capacity development, that can amount to a 24-h training week. The training stimuli and consequent metabolic demands of each session in a rowing training program differ depending on type, length, and intensity. Nutrition guidelines for endurance- and power-based sports should be drawn upon; however, individualized and flexible nutrition plans are critical to successfully meet the daily, weekly, and cyclic nutrient requirements of a rower. This review will provide an overview of key nutritional strategies to optimize training and enhance adaptation, and briefly discuss supplement strategies that may support health and enhance performance in elite rowing.

  3. Data explosion: the challenge of multidetector-row CT

    International Nuclear Information System (INIS)

    Rubin, Geoffrey D.

    2000-01-01

    The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-row CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that some of these future developments might take are discussed

  4. Data explosion: the challenge of multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Rubin, Geoffrey D. E-mail: grubin@standford.edu

    2000-11-01

    The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-row CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that some of these future developments might take are discussed.

  5. Comparisons of solar radiation interception, albedo and net radiation as influenced by row orientations of crops

    International Nuclear Information System (INIS)

    Baten, Md.A.; Kon, H.

    1997-01-01

    Field experiments were conducted on soybean (Glycin max L.) in summer and potato (Solanum tuberosum L.) in autumn to evaluate the effect of row orientations of crops on some selected micro meteorological factors during 1994 and 1995. The intercepted solar radiation was the largest in the plants growing in bidirection in summer and it exhibited intermediate trend in autumn as compared to E-W or N-S row orientations. In summer, penetrated solar radiation between two plants and near the stem base of a N-S row was larger than that of E-W row. While in autumn, the observed solar radiation between two plants and near the stem base of a E-W row was markedly larger than that of N-S row. The area weighted mean of penetrated solar radiation was larger in E-W soybean rows but lower in potato rows as compared to N-S row orientations. Soil surface temperature between N-S potato rows was larger than that of E-W potato rows and the upper canopy surface temperature of potato was larger in E-W rows as compared to N-S rows. Net radiation observed over E-W potato rows was larger as compared to N-S potato rows but net radiation measured under canopy of E-W potato rows was smaller than that of in N-S rows. Net radiation measured over N-S soybean rows was larger than that of E-W soybean rows and it was smaller between N-S soybean rows when measured under canopy as compared to E-W rows. The albedo observed over potato was larger over E-W rows as compared to N-S rows. Albedos over soybean canopy showed opposite trend with the albedos observed over potato canopy. It was larger over N-S rows as compared to E-W rows. High harvest index was associated with larger interception of radiation. (author)

  6. Evaluation of multimodal feedback effects on improving rowing competencies

    Directory of Open Access Journals (Sweden)

    Korman Maria

    2011-12-01

    Full Text Available This study focused on the selection and preliminary evaluation of different types of modal and information feedback in virtual environment to facilitate acquisition and transfer of a complex motor-cognitive skill of rowing. Specifically, we addressed the effectiveness of immediate information feedback provided visually as compared to sensory haptic feedback on the improvement in hands kinematics and changes in cognitive load during the course of learning the basic rowing technique. Several pilot experiments described in this report lead to the evaluation and optimization of the training protocol, to enhance facilitatory effects of adding visual and haptic feedback during training.

  7. Generalized Row-Action Methods for Tomographic Imaging

    DEFF Research Database (Denmark)

    Andersen, Martin Skovgaard; Hansen, Per Christian

    2014-01-01

    Row-action methods play an important role in tomographic image reconstruction. Many such methods can be viewed as incremental gradient methods for minimizing a sum of a large number of convex functions, and despite their relatively poor global rate of convergence, these methods often exhibit fast...... initial convergence which is desirable in applications where a low-accuracy solution is acceptable. In this paper, we propose relaxed variants of a class of incremental proximal gradient methods, and these variants generalize many existing row-action methods for tomographic imaging. Moreover, they allow...

  8. Single-row versus double-row capsulolabral repair: a comparative evaluation of contact pressure and surface area in the capsulolabral complex-glenoid bone interface.

    Science.gov (United States)

    Kim, Doo-Sup; Yoon, Yeo-Seung; Chung, Hoi-Jeong

    2011-07-01

    Despite the attention that has been paid to restoration of the capsulolabral complex anatomic insertion onto the glenoid, studies comparing the pressurized contact area and mean interface pressure at the anatomic insertion site between a single-row repair and a double-row labral repair have been uncommon. The purpose of our study was to compare the mean interface pressure and pressurized contact area at the anatomic insertion site of the capsulolabral complex between a single-row repair and a double-row repair technique. Controlled laboratory study. Thirty fresh-frozen cadaveric shoulders (mean age, 61 ± 8 years; range, 48-71 years) were used for this study. Two types of repair were performed on each specimen: (1) a single-row repair and (2) a double-row repair. Using pressure-sensitive films, we examined the interface contact area and contact pressure. The mean interface pressure was greater for the double-row repair technique (0.29 ± 0.04 MPa) when compared with the single-row repair technique (0.21 ± 0.03 MPa) (P = .003). The mean pressurized contact area was also significantly greater for the double-row repair technique (211.8 ± 18.6 mm(2), 78.4% footprint) compared with the single-row repair technique (106.4 ± 16.8 mm(2), 39.4% footprint) (P = .001). The double-row repair has significantly greater mean interface pressure and pressurized contact area at the insertion site of the capsulolabral complex than the single-row repair. The double-row repair may be advantageous compared with the single-row repair in restoring the native footprint area of the capsulolabral complex.

  9. ROW (Right-of-Way) interfering construction activities management program

    Energy Technology Data Exchange (ETDEWEB)

    Rosito, Roberta; Oliveira, Marisa; Lima, Shirley [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    A significant portion of pipeline failures occurs due to external damage. This includes third party right of way (ROW) encroachment, which shall be identified and avoided. However, injuries caused by known and planned activities do happen. Construction of crossing or sharing ROW pipelines, crossing roads and bridges, neighboring buildings and excavations of any kind might put existing pipelines in risk. This paper presents how the TRANSPETRO ROW Interfering Construction Activities Management Program is implemented by a regional ROW maintenance department responsible for more than 3,000 km of pipelines, mostly in Rio de Janeiro and Minas Gerais states. This program is based on a TRANSPETRO procedure that was written after the publication of the Official Order number 125 of ANP (Oil, Gas and Biofuel Brazilian National Agency). Tasks from design review and approval to field construction supervision are performed by the staff responsible for the routine patrols and maintenance management. The ability of foreseeing risky activities is improved by expertise gained from day-to-day work on site. (author)

  10. Effect of intercropping sunflower with soybean at different inter- row ...

    African Journals Online (AJOL)

    ACSS

    confectionary types of Russian and. Kenyan origin, with low (10-30%) oil content. These varieties were brought by religious organisations mainly to Karamoja .... low competition among plants. One hundred seed weight was significantly affected by inter-row spacing. (Table 1). Heavy seeds were obtained from 90, 105 and ...

  11. Profitability of cover crops for single and twin row cotton

    Science.gov (United States)

    With the increased interest in cover crops, the impact of adoption on profitability of cash crops is a common question from producers. The objective of this study was to evaluate the profitability of cover crops for single and twin row cotton (Gossypium hirsutum L.) in Alabama. This experiment inclu...

  12. Rowing Sport in Learning Fractions of the Fourth Grade Students

    Directory of Open Access Journals (Sweden)

    Marhamah Fajriyah Nasution

    2017-06-01

    Full Text Available This study aimed to produce learning trajectory with rowing context that can help students understand addition and subtraction of fractions. Subject of the research were students IV MIN 2 Palembang. The method used was research design with three stages, those are preparing for the experiment, the design experiments, and the retrospective analysis. Learning trajectory was designed from in-formal stage to the formal stage. At the informal stage, Rowing was used as a starting point to explore the students’ knowledge of fractions. Data collection conducted through video recordings and photos to see the learning process in the classroom, written tests, observation and interviews during the learning process with the students which is the subject of research. Research produced learning trajectory consisting of a series of learning addition and subtraction of fractions dealing with the rowing. The results showed that the use of the rowing can be a bridge of students' thinking and help students in understanding the operation of addition and subtraction of fractions.

  13. On the biased n-in-a-row game

    NARCIS (Netherlands)

    Csorba, P.

    2005-01-01

    The biased version of the n-in-a-row game1 is rather boring. The player who can occupy more points per move has a winning strategy [J. Beck, Tic-Tac-Toe Theory, Cambridge University Press, Cambridge, 2006, to appear] for any n. In order to make this game more interesting József Beck suggested to

  14. Spatiotemporal throughfall patterns beneath an urban tree row

    Science.gov (United States)

    Bogeholz, P.; Van Stan, J. T., II; Hildebrandt, A.; Friesen, J.; Dibble, M.; Norman, Z.

    2016-12-01

    Much recent research has focused on throughfall patterns in natural forests as they can influence the heterogeneity of surface ecohydrological and biogeochemical processes. However, to the knowledge of the authors, no work has assessed how urban forest structures affect the spatiotemporal variability of throughfall water flux. Urbanization greatly alters not only a significant portion of the land surface, but canopy structure, with the most typical urban forest configuration being landscaped tree rows along streets, swales, parking lot medians, etc. This study examines throughfall spatiotemporal patterns for a landscaped tree row of Pinus elliottii (Engelm., slash pine) on Georgia Southern University's campus (southeastern, USA) using 150 individual observations per storm. Throughfall correlation lengths beneath this tree row were similar to, but appeared to be more stable across storm size than, observations in past studies on natural forests. Individual tree overlap and the planting interval also may more strongly drive throughfall patterns in tree rows. Meteorological influences beyond storm magnitude (intensity, intermittency, wind conditions, and atmospheric moisture demand) are also examined.

  15. Usefulness of multi-detector row Computed Tomography for ...

    African Journals Online (AJOL)

    A 74-year-old female underwent surgical treatment for adenocarcinoma of the pancreatic head. Preoperative multi-detector row computed tomography (MD-CT) demonstrated tumor invasion into the accessory right colic vein and the branch of the middle colic artery (MCA), which was not detected by digital subtraction ...

  16. Exploring Multiplication: Three-in-a-Row Lucky Numbers

    Science.gov (United States)

    Russo, James A.

    2018-01-01

    Three-in-a-Row Lucky Numbers is an engaging, enjoyable, mathematically meaningful, game-based activity involving dice and a hundred chart, which can be used to introduce students to multiplication. The game provides a mechanism for students to explore the structure of multiplication, experiment with the distributive property, and begin to…

  17. A CMOS image sensor with row and column profiling means

    NARCIS (Netherlands)

    Xie, N.; Theuwissen, A.J.P.; Wang, X.; Leijtens, J.A.P.; Hakkesteegt, H.; Jansen, H.

    2008-01-01

    This paper describes the implementation and firstmeasurement results of a new way that obtains row and column profile data from a CMOS Image Sensor, which is developed for a micro-Digital Sun Sensor (μDSS).The basic profiling action is achieved by the pixels with p-type MOS transistors which realize

  18. Experimental study of the characteristics of the flow in the first rows of tube banks

    International Nuclear Information System (INIS)

    Olinto, Claudio R.; Indrusiak, Maria Luiza S.; Endres, Luiz Augusto M.; Moeller, Sergio V.

    2009-01-01

    This paper presents the experimental study of the flow instabilities in the first rows of tube banks. The study is performed using hot wire anemometry technique in an aerodynamic channel as well as flow visualizations in a water channel. In the wind channel three tube banks with square arrangement and pitch to diameter ratios P/D = 1.26, 1.4 and 1.6 were studied. The Reynolds number range for the velocities measurements, computed with the tube diameter and the flow velocity in the narrow gap between tubes was 7 x 10 4 -8 x 10 4 . Continuous and discrete wavelets were applied to decompose the velocity results, thus allowing the analysis of phenomena in time-frequency domain. Visualizations in a water channel complemented the analysis of the hot wire results. For this purpose, dye was injected in the flow in the water channel with a tube bank with P/D = 1.26. The range of the Reynolds number of the experiments was 3 x 10 4 -4 x 10 4 . The main results show the presence of instabilities, generated after the second row of the tube bank, which propagates to the interior of the bank. In the resulting flow, the three orthogonal components are equally significant. The three-dimensional behavior of the flow is responsible for a mass redistribution inside the bank that leads to velocity values not expected for the studied geometry, according to the known literature. The resulting flow process can be interpreted as a secondary flow which is characteristic of tube banks.

  19. Velocity selection for ultra-cold atoms using bimodal mazer cavity

    International Nuclear Information System (INIS)

    Irshad, A.; Qamar, S.

    2009-04-01

    In this paper, we discuss the velocity selection of ultra-cold three-level atoms in Λ configuration using a micromazer. Our model is the same as discussed by Arun et al., for mazer action in a bimodal cavity. We have shown that significantly narrowed velocity distribution of ultra-cold atoms can be obtained in this system due to the presence of dark states. (author)

  20. Design, Construction and Evaluation of a Row Crop Thinning Machine

    Directory of Open Access Journals (Sweden)

    M Gol Mohammadi

    2014-04-01

    Full Text Available Equipment availability is necessary in the development of Agriculture mechanization. Crop thinning is one of the most important stages in row crop production which is laborious and costly. The objective of this project is design and construction of a row crop thinning machine. Four main system units are plant sensors, ground sensors, control and thinning platforms. In this machine the unwanted plants on the rows are randomly removed by employing a pneumatically system. A blade on a vertical arm with pendulum motion removes the plant from the rows. The machine control system consists of an arm and a blade which is activated by a double acting cylinder and equipped with a relay and a timer. The pneumatic cylinder is controlled via a solenoid valve. Laboratory tests were conducted to validate the machine performance. Some other preliminary tests also were performed for optimization of parameters such as cinematic index and cutting length of blades. The laboratory tests (totally 9 tests were performed with a constant forward speed and three levels of plant density, using artificial plants. The data were analyzed using SPSS software. The results show that satisfactory performance of the machine is achieved when the plant density is moderate i.e. the thinning performance reduces with higher plant distance in the row. The other effective variable on machine performance is the adjustment of sensor sensitivity, which is used to distinguish between week and strong plants. In general the machine performance is sensitive to plant shape and morphology, plant distribution pattern in the field, growing stage of the plants, time of thinning and the effectiveness of previous weeding operations

  1. Device Physics of Narrow Gap Semiconductors

    CERN Document Server

    Chu, Junhao

    2010-01-01

    Narrow gap semiconductors obey the general rules of semiconductor science, but often exhibit extreme features of these rules because of the same properties that produce their narrow gaps. Consequently these materials provide sensitive tests of theory, and the opportunity for the design of innovative devices. Narrow gap semiconductors are the most important materials for the preparation of advanced modern infrared systems. Device Physics of Narrow Gap Semiconductors offers descriptions of the materials science and device physics of these unique materials. Topics covered include impurities and defects, recombination mechanisms, surface and interface properties, and the properties of low dimensional systems for infrared applications. This book will help readers to understand not only the semiconductor physics and materials science, but also how they relate to advanced opto-electronic devices. The last chapter applies the understanding of device physics to photoconductive detectors, photovoltaic infrared detector...

  2. Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro, E-mail: kitajima@med.kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Maeda, Tetsuo; Ohno, Yoshiharu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Division of Radiology, Kobe University Hospital, Kobe (Japan); Yoshikawa, Takeshi [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Konishi, Minoru [Division of Radiology, Kobe University Hospital, Kobe (Japan); Kanda, Tomonori; Onishi, Yumiko; Matsumoto, Keiko; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan)

    2011-11-15

    Objective: To compare the capability of 320-detector row CT (area-detector CT: ADCT) with step-and-shoot scan protocol for small abdominal vasculature assessment with that of 64-detector row CT with helical scan protocol. Materials and methods: Total of 60 patients underwent contrast-enhanced abdominal CT for preoperative assessment. Of all, 30 suspected to have lung cancer underwent ADCT using step-and-shoot scan protocol. The other 30 suspected to have renal cell carcinoma underwent 64-MDCT using helical scan protocol. Two experienced radiologists independently assessed inferior epigastric, hepatic subsegmental (in the segment 8), mesenteric marginal (Griffith point) and inferior phrenic arteries by using 5-point visual scoring systems. Kappa analysis was used for evaluation of interobserver agreement. To compare the visualization capability of the two systems, the Mann-Whitney U-test was used to compare the scores for each of the arteries. Results: Overall interobserver agreements for both systems were almost perfect ({kappa} > 0.80). Visualization scores for inferior epigastric and mesenteric arteries were significantly higher for ADCT than for 64-detector row CT (p < 0.05). No significant difference was found for hepatic subsegmental and inferior phrenic arteries. Conclusion: Small abdominal vasculature assessment by ADCT with step-and-shoot scan protocol is potentially equal to or better than that by 64-detector row CT with helical scan protocol.

  3. Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT

    International Nuclear Information System (INIS)

    Kitajima, Kazuhiro; Maeda, Tetsuo; Ohno, Yoshiharu; Yoshikawa, Takeshi; Konishi, Minoru; Kanda, Tomonori; Onishi, Yumiko; Matsumoto, Keiko; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro

    2011-01-01

    Objective: To compare the capability of 320-detector row CT (area-detector CT: ADCT) with step-and-shoot scan protocol for small abdominal vasculature assessment with that of 64-detector row CT with helical scan protocol. Materials and methods: Total of 60 patients underwent contrast-enhanced abdominal CT for preoperative assessment. Of all, 30 suspected to have lung cancer underwent ADCT using step-and-shoot scan protocol. The other 30 suspected to have renal cell carcinoma underwent 64-MDCT using helical scan protocol. Two experienced radiologists independently assessed inferior epigastric, hepatic subsegmental (in the segment 8), mesenteric marginal (Griffith point) and inferior phrenic arteries by using 5-point visual scoring systems. Kappa analysis was used for evaluation of interobserver agreement. To compare the visualization capability of the two systems, the Mann-Whitney U-test was used to compare the scores for each of the arteries. Results: Overall interobserver agreements for both systems were almost perfect (κ > 0.80). Visualization scores for inferior epigastric and mesenteric arteries were significantly higher for ADCT than for 64-detector row CT (p < 0.05). No significant difference was found for hepatic subsegmental and inferior phrenic arteries. Conclusion: Small abdominal vasculature assessment by ADCT with step-and-shoot scan protocol is potentially equal to or better than that by 64-detector row CT with helical scan protocol.

  4. Ultra-high Performance Liquid Chromatography in Steroid Analysis

    OpenAIRE

    Salonen, Fanny

    2017-01-01

    The latest version of liquid chromatography is ultra-high performance (or pressure) chromatography (UHPLC). In the technique, short and narrow-bore columns with particle sizes below 3 µm are used. The extremely high pressure used results in very short analysis times, excellent separation, and good resolution. This makes UHPLC a good choice for steroidal analysis. Steroids are a highly interesting area of study; they can be recognized as biomarkers for several diseases and are a relevant topic...

  5. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs

    OpenAIRE

    Dorweiler, Matthew A.; Van Dyke, Rufus O.; Siska, Robert C.; Boin, Michael A.; DiPaola, Mathew J.

    2017-01-01

    Background: Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. Hypothesis: The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Study Design: Controlled laboratory study. Methods: Eighteen ca...

  6. Biomechanical Comparison of Single- Versus Double-Row Capsulolabral Repair for Shoulder Instability: A Review.

    Science.gov (United States)

    Yousif, Matthew John; Bicos, James

    2017-12-01

    The glenohumeral joint is the most commonly dislocated joint in the body. Failure rates of capsulolabral repair have been reported to be approximately 8%. Recent focus has been on restoration of the capsulolabral complex by a double-row capsulolabral repair technique in an effort to decrease redislocation rates after arthroscopic capsulolabral repair. To present a review of the biomechanical literature comparing single- versus double-row capsulolabral repairs and discuss the previous case series of double-row fixation. Narrative review. A simple review of the literature was performed by PubMed search. Only biomechanical studies comparing single- versus double-row capsulolabral repair were included for review. Only those case series and descriptive techniques with clinical results for double-row repair were included in the discussion. Biomechanical comparisons evaluating the native footprint of the labrum demonstrated significantly superior restoration of the footprint through double-row capsulolabral repair compared with single-row repair. Biomechanical comparisons of contact pressure at the repair interface, fracture displacement in bony Bankart lesion, load to failure, and decreased external rotation (suggestive of increased load to failure) were also significantly in favor of double- versus single-row repair. Recent descriptive techniques and case series of double-row fixation have demonstrated good clinical outcomes; however, no comparative clinical studies between single- and double-row repair have assessed functional outcomes. The superiority of double-row capsulolabral repair versus single-row repair remains uncertain because comparative studies assessing clinical outcomes have yet to be performed.

  7. 77 FR 74237 - T. Rowe Price Associates, Inc., et al.; Notice of Application

    Science.gov (United States)

    2012-12-13

    ... Price Associates, Inc., et al.; Notice of Application December 7, 2012. AGENCY: Securities and Exchange... sections 12(d)(1)(A) and (B) of the Act. Applicants: T. Rowe Price Associates, Inc. (``TRP''), T. Rowe Price Institutional Income Funds, Inc. (the ``Corporation'') and T. Rowe Price Investment Services, Inc...

  8. Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade III partial articular-sided rotator cuff tears.

    Science.gov (United States)

    Zhang, Chun-Gang; Zhao, De-Wei; Wang, Wei-Ming; Ren, Ming-Fa; Li, Rui-Xin; Yang, Sheng; Liu, Yu-Peng

    2010-11-01

    For partial-thickness tears of the rotator cuff, double-row fixation and transtendon single-row fixation restore insertion site anatomy, with excellent results. We compared the biomechanical properties of double-row and transtendon single-row suture anchor techniques for repair of grade III partial articular-sided rotator cuff tears. In 10 matched pairs of fresh-frozen sheep shoulders, the infraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique. This comprised placement of 2 medial anchors with horizontal mattress sutures at an angle of ≤ 45° into the medial margin of the infraspinatus footprint, just lateral to the articular surface, and 2 lateral anchors with horizontal mattress sutures. Standardized, 50% partial, articular-sided infraspinatus lesions were created in the contralateral shoulder. The infraspinatus tendon from the contralateral shoulder was repaired using two anchors with transtendon single-row mattress sutures. Each specimen underwent cyclic loading from 10 to 100 N for 50 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a motion capture system; stiffness and failure load were determined from testing data. Gap formation for the transtendon single-row repair was significantly smaller (P row repair for the first cycle ((1.74 ± 0.38) mm vs. (2.86 ± 0.46) mm, respectively) and the last cycle ((3.77 ± 0.45) mm vs. (5.89 ± 0.61) mm, respectively). The strain over the footprint area for the transtendon single-row repair was significantly smaller (P row repair. Also, it had a higher mean ultimate tensile load and stiffness. For grade III partial articular-sided rotator cuff tears, transtendon single-row fixation exhibited superior biomechanical properties when compared with double-row fixation.

  9. Three-dimensional evaluation of cyclic displacement in single-row and double-row rotator cuff reconstructions under static external rotation.

    Science.gov (United States)

    Lorbach, Olaf; Kieb, Matthias; Raber, Florian; Busch, Lüder C; Kohn, Dieter M; Pape, Dietrich

    2013-01-01

    The double-row suture bridge repair was recently introduced and has demonstrated superior biomechanical results and higher yield load compared with the traditional double-row technique. It therefore seemed reasonable to compare this second generation of double-row constructs to the modified single-row double mattress reconstruction. The repair technique, initial tear size, and tendon subregion will have a significant effect on 3-dimensional (3D) cyclic displacement under additional static external rotation of a modified single-row compared with a double-row rotator cuff repair. Controlled laboratory study. Rotator cuff tears (small to medium: 25 mm; medium to large: 35 mm) were created in 24 human cadaveric shoulders. Rotator cuff repairs were performed as modified single-row or double-row repairs, and cyclic loading (10-60 N, 10-100 N) was applied under 20° of external rotation. Radiostereometric analysis was used to calculate cyclic displacement in the anteroposterior (x), craniocaudal (y), and mediolateral (z) planes with a focus on the repair constructs and the initial tear size. Moreover, differences in cyclic displacement of the anterior compared with the posterior tendon subregions were calculated. Significantly lower cyclic displacement was seen in small to medium tears for the single-row compared with double-row repair at 60 and 100 N in the x plane (P = .001) and y plane (P = .001). The results were similar in medium to large tears at 100 N in the x plane (P = .004). Comparison of 25-mm versus 35-mm tears did not show any statistically significant differences for the single-row repairs. In the double-row repairs, lower gap formation was found for the 35-mm tears (P ≤ .05). Comparison of the anterior versus posterior tendon subregions revealed a trend toward higher anterior gap formation, although this was statistically not significant. The tested single-row reconstruction achieved superior results in 3D cyclic displacement to the tested double-row

  10. Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?

    Science.gov (United States)

    Pauly, Stephan; Gerhardt, Christian; Chen, Jianhai; Scheibel, Markus

    2010-12-01

    Several techniques for arthroscopic repair of rotator cuff defects have been introduced over the past years. Besides established techniques such as single-row repairs, new techniques such as double-row reconstructions have gained increasing interest. The present article therefore provides an overview of the currently available literature on both repair techniques with respect to several anatomical, biomechanical, clinical and structural endpoints. Systematic literature review of biomechanical, clinical and radiographic studies investigating or comparing single- and double-row techniques. These results were evaluated and compared to provide an overview on benefits and drawbacks of the respective repair type. Reconstructions of the tendon-to-bone unit for full-thickness tears in either single- or double-row technique differ with respect to several endpoints. Double-row repair techniques provide more anatomical reconstructions of the footprint and superior initial biomechanical characteristics when compared to single-row repair. With regard to clinical results, no significant differences were found while radiological data suggest a better structural tendon integrity following double-row fixation. Presently published clinical studies cannot emphasize a clearly superior technique at this time. Available biomechanical studies are in favour of double-row repair. Radiographic studies suggest a beneficial effect of double-row reconstruction on structural integrity of the reattached tendon or reduced recurrent defect rates, respectively.

  11. Does double-row rotator cuff repair improve functional outcome of patients compared with single-row technique? A systematic review.

    Science.gov (United States)

    DeHaan, Alexander M; Axelrad, Thomas W; Kaye, Elizabeth; Silvestri, Lorenzo; Puskas, Brian; Foster, Timothy E

    2012-05-01

    The advantage of single-row versus double-row arthroscopic rotator cuff repair techniques has been a controversial issue in sports medicine and shoulder surgery. There is biomechanical evidence that double-row techniques are superior to single-row techniques; however, there is no clinical evidence that the double-row technique provides an improved functional outcome. When compared with single-row rotator cuff repair, double-row fixation, although biomechanically superior, has no clinical benefit with respect to retear rate or improved functional outcome. Systematic review. The authors reviewed prospective studies of level I or II clinical evidence that compared the efficacy of single- and double-row rotator cuff repairs. Functional outcome scores included the American Shoulder and Elbow Surgeons (ASES) shoulder scale, the Constant shoulder score, and the University of California, Los Angeles (UCLA) shoulder rating scale. Radiographic failures and complications were also analyzed. A test of heterogeneity for patient demographics was also performed to determine if there were differences in the patient profiles across the included studies. Seven studies fulfilled our inclusion criteria. The test of heterogeneity across these studies showed no differences. The functional ASES, Constant, and UCLA outcome scores revealed no difference between single- and double-row rotator cuff repairs. The total retear rate, which included both complete and partial retears, was 43.1% for the single-row repair and 27.2% for the double-row repair (P = .057), representing a trend toward higher failures in the single-row group. Through a comprehensive literature search and meta-analysis of current arthroscopic rotator cuff repairs, we found that the single-row repairs did not differ from the double-row repairs in functional outcome scores. The double-row repairs revealed a trend toward a lower radiographic proven retear rate, although the data did not reach statistical significance. There

  12. New NS varieties of six-rowed winter barley

    Directory of Open Access Journals (Sweden)

    Pržulj Novo

    2009-01-01

    Full Text Available The paper describes the characteristics of several new NS varieties of winter six-rowed barley released in Serbia between 2004 and 2007. These are Somborac, Ozren, Javor, Novosadski 773, Sremac and Leotar. In the official variety trials in the country, all six of these varieties outyielded the check variety, and the margins were as follows: Somborac - 3.4%, Ozren - 5.0%, Javor - 7.3%, Novosadski 773 - 3.4%, Sremac - 7.4%, and Leotar - 7.2%. Yield levels in absolute terms depended on the variety as well as year. All six-rowed NS varieties headed earlier than the check and had better resistance to lodging than the check has. The test weight of the new varieties was 70.2-73.8 kg/hl and the 1000-grain weight 33.4-50.2 g. The cellulose content was 4.4-4.8%, the fat content 1.4%, and the protein content 13.3-14.6%. The high variability of the new NS varieties of winter six-rowed barley makes it possible to choose the most suitable genotype for each barley-growing area in the country. .

  13. Colin Rowe: Space as well-composed illusion

    Directory of Open Access Journals (Sweden)

    Christoph Schnoor

    2011-12-01

    Full Text Available Architectural historian Colin Rowe, although well known for his intriguing analytical writings on modern architecture, rarely examined architectural space as a scholarly subject-matter. Historians examining Rowe’s writings rarely refer to the issue of space, either. Anthony Vidler, Werner Oechslin, Alexander Caragonne and others have examined Rowe’s investigations into urban space, his analyses of formal principles in architecture, or his critical stance towards the myths of modernism, but have not singled out architectural space as subject matter. Nevertheless, this paper argues that Rowe is indeed one of the few post-war historians writing in the English language to have conveyed analyses of architectural space, particularly in the volume The Mathematics of the Ideal Villa (1976. The paper examines how Rowe understood architectural space as relevant only when not seen as ‘pure’ but ‘contaminated’ with ambiguity and active character: notions of flatness versus depth and horizontal versus vertical, as well as the overlapping of conflicting scales or whole structural or spatial systems are central for Rowe’s reading of architectural space, which is also always infused with an idea of movement. Further, the paper traces influences of Rowe’s approach beyond the obvious influence by Rudolf Wittkower to Heinrich Wölfflin’s style and method, partially conveyed through the translation of Sigfried Giedion’s writings.

  14. Highly Tunable Narrow Bandpass MEMS Filter

    KAUST Repository

    Hafiz, Md Abdullah Al

    2017-07-07

    We demonstrate a proof-of-concept highly tunable narrow bandpass filter based on electrothermally and electrostatically actuated microelectromechanical-system (MEMS) resonators. The device consists of two mechanically uncoupled clamped-clamped arch resonators, designed such that their resonance frequencies are independently tuned to obtain the desired narrow passband. Through the electrothermal and electrostatic actuation, the stiffness of the structures is highly tunable. We experimentally demonstrate significant percentage tuning (~125%) of the filter center frequency by varying the applied electrothermal voltages to the resonating structures, while maintaining a narrow passband of 550 ± 50 Hz, a stopband rejection of >17 dB, and a passband ripple ≤ 2.5 dB. An analytical model based on the Euler-Bernoulli beam theory is used to confirm the behavior of the filter, and the origin of the high tunability using electrothermal actuation is discussed.

  15. Vision-GPS Fusion for Guidance of an Autonomous Vehicle in Row Crops

    DEFF Research Database (Denmark)

    Bak, Thomas

    2001-01-01

    This paper presents a real-time localization system for an autonomous vehicle passing through 0.25 m wide crop rows at 6 km/h. Localization is achieved by fusion of mea-surements from a row guidance sensor and a GPS receiver. Conventional agricultural practice applies inputs such as herbicide...... at a constant rate ignoring the spatial variability in weed, soil, and crop. Sensing with a guided vehicle allow cost effective mapping of field variability and inputs may be adjusted accordingly. Essential to such a vehicle is real-time localization. GPS allow precise absolute sensing but it is not practical...... to guide the vehicle relative to the crop rows on an absolute coordinate. A row guidance sensor is therefore included to sense the position relative to the rows. The vehicle path in the field is re-planned online in order to allow for crop row irregularities sensed by the row sensor. The path generation...

  16. Ultra wide band antennas

    CERN Document Server

    Begaud, Xavier

    2013-01-01

    Ultra Wide Band Technology (UWB) has reached a level of maturity that allows us to offer wireless links with either high or low data rates. These wireless links are frequently associated with a location capability for which ultimate accuracy varies with the inverse of the frequency bandwidth. Using time or frequency domain waveforms, they are currently the subject of international standards facilitating their commercial implementation. Drawing up a complete state of the art, Ultra Wide Band Antennas is aimed at students, engineers and researchers and presents a summary of internationally recog

  17. Natural Convective Heat Transfer from Narrow Plates

    CERN Document Server

    Oosthuizen, Patrick H

    2013-01-01

    Natural Convective Heat Transfer from Narrow Plates deals with a heat transfer situation that is of significant practical importance but which is not adequately dealt with in any existing textbooks or in any widely available review papers. The aim of the book is to introduce the reader to recent studies of natural convection from narrow plates including the effects of plate edge conditions, plate inclination, thermal conditions at the plate surface and interaction of the flows over adjacent plates. Both numerical and experimental studies are discussed and correlation equations based on the results of these studies are reviewed.

  18. A naturally narrow positive-parity Θ+

    International Nuclear Information System (INIS)

    Carlson, Carl E.; Carone, Christopher D.; Kwee, Herry J.; Nazaryan, Vahagn

    2004-01-01

    We present a consistent color-flavor-spin-orbital wave function for a positive-parity Θ + that naturally explains the observed narrowness of the state. The wave function is totally symmetric in its flavor-spin part and totally antisymmetric in its color-orbital part. If flavor-spin interactions dominate, this wave function renders the positive-parity Θ + lighter than its negative-parity counterpart. We consider decays of the Θ + and compute the overlap of this state with the kinematically allowed final states. Our results are numerically small. We note that dynamical correlations between quarks are not necessary to obtain narrow pentaquark widths

  19. Narrow Escape of Interacting Diffusing Particles

    Science.gov (United States)

    Agranov, Tal; Meerson, Baruch

    2018-03-01

    The narrow escape problem deals with the calculation of the mean escape time (MET) of a Brownian particle from a bounded domain through a small hole on the domain's boundary. Here we develop a formalism which allows us to evaluate the nonescape probability of a gas of diffusing particles that may interact with each other. In some cases the nonescape probability allows us to evaluate the MET of the first particle. The formalism is based on the fluctuating hydrodynamics and the recently developed macroscopic fluctuation theory. We also uncover an unexpected connection between the narrow escape of interacting particles and thermal runaway in chemical reactors.

  20. Tunable Narrow Band Gap Absorbers For Ultra High Efficiency Solar Cells

    Energy Technology Data Exchange (ETDEWEB)

    Bedair, Salah M. [North Carolina State Univ., Raleigh, NC (United States); Hauser, John R. [North Carolina State Univ., Raleigh, NC (United States); Elmasry, Nadia [North Carolina State Univ., Raleigh, NC (United States); Colter, Peter C. [North Carolina State Univ., Raleigh, NC (United States); Bradshaw, G. [North Carolina State Univ., Raleigh, NC (United States); Carlin, C. Z. [North Carolina State Univ., Raleigh, NC (United States); Samberg, J. [North Carolina State Univ., Raleigh, NC (United States); Edmonson, Kenneth [Spectrolab, Inc., Sylmar, CA (United States)

    2012-07-31

    We report on a joint research program between NCSU and Spectrolab to develop an upright multijunction solar cell structure with a potential efficiency exceeding the current record of 41.6% reported by Spectrolab. The record efficiency Ge/GaAs/InGaP triple junction cell structure is handicapped by the fact that the current generated by the Ge cell is much higher than that of both the middle and top cells. We carried out a modification of the record cell structure that will keep the lattice matched condition and allow better matching of the current generated by each cell. We used the concept of strain balanced strained layer superlattices (SLS), inserted in the i-layer, to reduce the bandgap of the middle cell without violating the desirable lattice matched condition. For the middle GaAs cell, we have demonstrated an n-GaAs/i-(InGaAs/GaAsP)/p-GaAs structure, where the InxGa1-xAs/GaAs1-yPy SLS is grown lattice matched to GaAs and with reduced bandgap from 1.43 eV to 1.2 eV, depending upon the values of x and y.

  1. Mode of inheritance and combining abilities for kernel row number, kernel number per row and grain yield in maize (Zea mays L.)

    NARCIS (Netherlands)

    Bocanski, J.; Sreckov, Z.; Nastasic, A.; Ivanovic, M.; Djalovic, I.; Vukosavljev, M.

    2010-01-01

    Bocanski J., Z. Sreckov, A. Nastasic, M. Ivanovic, I.Djalovic and M. Vukosavljev (2010): Mode of inheritance and combining abilities for kernel row number, kernel number per row and grain yield in maize (Zea mays L.) - Genetika, Vol 42, No. 1, 169- 176. Utilization of heterosis requires the study of

  2. Narrow linewidth pulsed optical parametric oscillator

    Indian Academy of Sciences (India)

    Tunable narrow linewidth radiation by optical parametric oscillation has many applications, particularly in spectroscopic investigation. In this paper, different techniques such as injection seeding, use of spectral selecting element like grating, grating and etalon in combination, grazing angle of incidence, entangled cavity ...

  3. ULTRA-LIGHTWEIGHT CEMENT

    Energy Technology Data Exchange (ETDEWEB)

    Fred Sabins

    2001-10-23

    The objective of this project is to develop an improved ultra-lightweight cement using ultra-lightweight hollow glass spheres (ULHS). Work reported herein addresses tasks performed in the fourth quarter as well as the other three quarters of the past year. The subjects that were covered in previous reports and that are also discussed in this report include: Analysis of field laboratory data of active cement applications from three oil-well service companies; Preliminary findings from a literature review focusing on problems associated with ultra-lightweight cements; Summary of pertinent information from Russian ultra-lightweight cement literature review; and Comparison of compressive strengths of ULHS systems using ultrasonic and crush methods Results reported from the fourth quarter include laboratory testing of ULHS systems along with other lightweight cement systems--foamed and sodium silicate slurries. These comparison studies were completed for two different densities (10.0 and 11.5 lb/gal) and three different field application scenarios. Additional testing included the mechanical properties of ULHS systems and other lightweight systems. Studies were also performed to examine the effect that circulation by centrifugal pump during mixing has on breakage of ULHS.

  4. Double-Row Capsulolabral Repair Increases Load to Failure and Decreases Excessive Motion.

    Science.gov (United States)

    McDonald, Lucas S; Thompson, Matthew; Altchek, David W; McGarry, Michelle H; Lee, Thay Q; Rocchi, Vanna J; Dines, Joshua S

    2016-11-01

    Using a cadaver shoulder instability model and load-testing device, we compared biomechanical characteristics of double-row and single-row capsulolabral repairs. We hypothesized a greater reduction in glenohumeral motion and translation and a higher load to failure in a mattress double-row capsulolabral repair than in a single-row repair. In 6 matched pairs of cadaveric shoulders, a capsulolabral injury was created. One shoulder was repaired with a single-row technique, and the other with a double-row mattress technique. Rotational range of motion, anterior-inferior translation, and humeral head kinematics were measured. Load-to-failure testing measured stiffness, yield load, deformation at yield load, energy absorbed at yield load, load to failure, deformation at ultimate load, and energy absorbed at ultimate load. Double-row repair significantly decreased external rotation and total range of motion compared with single-row repair. Both repairs decreased anterior-inferior translation compared with the capsulolabral-injured condition, however, no differences existed between repair types. Yield load in the single-row group was 171.3 ± 110.1 N, and in the double-row group it was 216.1 ± 83.1 N (P = .02). Ultimate load to failure in the single-row group was 224.5 ± 121.0 N, and in the double-row group it was 373.9 ± 172.0 N (P = .05). Energy absorbed at ultimate load in the single-row group was 1,745.4 ± 1,462.9 N-mm, and in the double-row group it was 4,649.8 ± 1,930.8 N-mm (P = .02). In cases of capsulolabral disruption, double-row repair techniques may result in decreased shoulder rotational range of motion and improved load-to-failure characteristics. In cases of capsulolabral disruption, repair techniques with double-row mattress repair may provide more secure fixation. Double-row capsulolabral repair decreases shoulder motion and increases load to failure, yield load, and energy absorbed at yield load more than single-row repair. Published by

  5. Effect of sodium bicarbonate supplementation on 2000-m rowing performance.

    Science.gov (United States)

    Hobson, Ruth M; Harris, Roger C; Martin, Dan; Smith, Perry; Macklin, Ben; Elliott-Sale, Kirsty J; Sale, Craig

    2014-01-01

    The ability to buffer H+ could be vital to exercise performance, as high concentrations of H+ contribute to the development of fatigue. The authors examined the effect of sodium bicarbonate (SB) supplementation on 2000-m rowing-ergometer performance. Twenty male rowers (age 23 ± 4 y, height 1.85 ± 0.08 m, mass 82.5 ± 8.9 kg, 2000-m personal-best time 409 ± 16 s) completed two 2000-m rowing-ergometer time trials, separated by 48 h. Participants were supplemented before exercise with 0.3 g/kg body mass of SB or a placebo (maltodextrin; PLA). The trials were conducted using a double-blinded, randomized, counterbalanced crossover study design. Time to complete the 2000-m and time taken for each 500-m split were recorded. Blood lactate, bicarbonate, pH, and base excess were determined preexercise, immediately postexercise, and 5 min postexercise. Performance data were analyzed using paired t tests, as well as magnitude-based inferences; hematological data were analyzed using a repeated-measures ANOVA. Using paired t tests, there was no benefit of SB over PLA (P = .095). However, using magnitude-based inferences there was a likely beneficial effect of SB compared with PLA (PLA 412.0 ± 15.1 s, SB 410.7 ± 14.9 s). Furthermore, SB was 0.5 ± 1.2 s faster than PLA in the third 500 m (P = .035; possibly beneficial) and 1.1 ± 1.7 s faster in the fourth 500 m (P = .004; very likely beneficial). All hematological data were different between SB and PLA and were different from preexercise to postexercise. SB supplementation is likely to be beneficial to the performance of those competing in 2000-m rowing events, particularly in the second half of the event.

  6. Evolution of deformation velocity in narrowing for Zircaloy 2

    Energy Technology Data Exchange (ETDEWEB)

    Cetlin, P R [Minas Gerais Univ., Belo Horizonte (Brazil). Dept. de Engenharia Metalurgica; Okuda, M Y [Goias Univ., Goiania (Brazil). Inst. de Matematica e Fisica

    1980-09-01

    Some studies on the deformation instability in strain shows that the differences in this instability may lead to localized narrowing or elongated narrowing, for Zircaloy-2. The variation of velocity deformation with the narrowing evolution is expected to be different for these two cases. The mentioned variation is discussed, a great difference in behavior having been observed for the case of localized narrowing.

  7. A row-charge nuclear cratering explosion in alluvial rocks

    International Nuclear Information System (INIS)

    Kireev, V.V.; Kedrovskij, O.L.; Valentinov, Yu.A.; Myasnikov, K.V.; Nikiforov, G.A.; Prozorov, L.B.; Potapov, V.K.

    1975-01-01

    A brief description is given of the first row-charge nuclear cratering explosion in alluvial rocks carried out on the route of the Pechora-Kolva canal. The authors explain the purposes of the explosion, describe the geological conditions, indicate the emplacement parameters and yields of the charges, present data on the dynamics of development of the explosion and report on its seismic effects. The parameters of the resulting trench cut and the characteristics of the rock ejecta are also given. The possibility of using nuclear explosions for hydrotechnological projects requiring large excavations in a thick stratum of weak water-bearing rocks is considered

  8. How many CT detector rows are necessary to perform adequate three dimensional visualization?

    International Nuclear Information System (INIS)

    Fischer, Lars; Tetzlaff, Ralf; Schoebinger, Max; Radeleff, Boris; Bruckner, Thomas; Meinzer, H.P.; Buechler, M.W.; Schemmer, Peter

    2010-01-01

    Introduction: The technical development of computer tomography (CT) imaging has experienced great progress. As consequence, CT data to be used for 3D visualization is not only based on 4 row CTs and 16 row CTs but also on 64 row CTs, respectively. The main goal of this study was to examine whether the increased amount of CT detector rows is correlated with improved quality of the 3D images. Material and Methods: All CTs were acquired during routinely performed preoperative evaluation. Overall, there were 12 data sets based on 4 detector row CT, 12 data sets based on 16 detector row CT, and 10 data sets based on 64 detector row CT. Imaging data sets were transferred to the DKFZ Heidelberg using the CHILI teleradiology system. For the analysis all CT scans were examined in a blinded fashion, i.e. both the name of the patient as well as the name of the CT brand were erased. For analysis, the time for segmentation of liver, both portal and hepatic veins as well as the branching depth of portal veins and hepatic veins was recorded automatically. In addition, all results were validated in a blinded fashion based on given quality index. Results: Segmentation of the liver was performed in significantly shorter time (p < 0.01, Kruskal-Wallis test) in the 16 row CT (median 479 s) compared to 4 row CT (median 611 s), and 64 row CT (median 670 s), respectively. The branching depth of the portal vein did not differ significantly among the 3 different data sets (p = 0.37, Kruskal-Wallis test). However, the branching depth of the hepatic veins was significantly better (p = 0.028, Kruskal-Wallis test) in the 4 row CT and 16 row CT compared to 64 row CT. The grading of the quality index was not statistically different for portal veins and hepatic veins (p = 0.80, Kruskal-Wallis test). Even though the total quality index was better for the vessel tree based on 64 row CT data sets (mean scale 2.6) compared to 4 CT row data (mean scale 3.25) and 16 row CT data (mean scale 3.0), these

  9. Analytical approximations for wide and narrow resonances

    International Nuclear Information System (INIS)

    Suster, Luis Carlos; Martinez, Aquilino Senra; Silva, Fernando Carvalho da

    2005-01-01

    This paper aims at developing analytical expressions for the adjoint neutron spectrum in the resonance energy region, taking into account both narrow and wide resonance approximations, in order to reduce the numerical computations involved. These analytical expressions, besides reducing computing time, are very simple from a mathematical point of view. The results obtained with this analytical formulation were compared to a reference solution obtained with a numerical method previously developed to solve the neutron balance adjoint equations. Narrow and wide resonances of U 238 were treated and the analytical procedure gave satisfactory results as compared with the reference solution, for the resonance energy range. The adjoint neutron spectrum is useful to determine the neutron resonance absorption, so that multigroup adjoint cross sections used by the adjoint diffusion equation can be obtained. (author)

  10. Analytical approximations for wide and narrow resonances

    Energy Technology Data Exchange (ETDEWEB)

    Suster, Luis Carlos; Martinez, Aquilino Senra; Silva, Fernando Carvalho da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: aquilino@lmp.ufrj.br

    2005-07-01

    This paper aims at developing analytical expressions for the adjoint neutron spectrum in the resonance energy region, taking into account both narrow and wide resonance approximations, in order to reduce the numerical computations involved. These analytical expressions, besides reducing computing time, are very simple from a mathematical point of view. The results obtained with this analytical formulation were compared to a reference solution obtained with a numerical method previously developed to solve the neutron balance adjoint equations. Narrow and wide resonances of U{sup 238} were treated and the analytical procedure gave satisfactory results as compared with the reference solution, for the resonance energy range. The adjoint neutron spectrum is useful to determine the neutron resonance absorption, so that multigroup adjoint cross sections used by the adjoint diffusion equation can be obtained. (author)

  11. Sacroiliitis in Ankylosing Spondylitis: Comparison with Multidetector Row CT and Plain Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ji Youn; Joo, Kyung Bin; Choi, Byeong Kyoo; Ryu, Jeong Ah; Kim, Tae Hwan; Choi, Woo Jung [Hanyang University Hospital, Seoul (Korea, Republic of)

    2009-03-15

    The objective of our study was to compare multidetector row CT and the plain radiographs for making the diagnosis and grading the sacroiliitis that accompanies ankylosing spondylitis. We wanted to determine the role of multidetector row CT for the evaluation of the sacroilitis in patients with ankylosing spondylitis. One hundred ninety two patients with clinically suspected ankylosing spondylitis were evaluated by conventional radiography and multidetector row CT. Two musculoskeletal radiologists retrospectively analyzed the images, and they graded the sacroiliitis using the modified New York Criteria. Multidetector row CT demonstrated a significantly higher sensitivity (74.5%, 83.3%) than did plain radiography (59.9%, 66.7%) for detecting early sacroiliitis (p<0.05). Multidetector row CT showed a higher grade of sacroiliitis in 114 and 127 of 384 sacroiliac joints. Performing multidetector row CT rather than plain radiography for making the diagnoses of accompanying ankylosing spondylitis allows an early start of treatment with a subsequently improved prognosis

  12. Arthroscopic Double-Row Transosseous Equivalent Rotator Cuff Repair with a Knotless Self-Reinforcing Technique.

    Science.gov (United States)

    Mook, William R; Greenspoon, Joshua A; Millett, Peter J

    2016-01-01

    Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. The preferred technique for rotator cuff repair of the senior author was reviewed and described in a step by step fashion. The final construct is a knotless double row transosseous equivalent construct. The described technique includes the advantages of a double-row construct while also offering self reinforcement, decreased risk of suture cut through, decreased risk of medial row overtensioning and tissue strangulation, improved vascularity, the efficiency of a knotless system, and no increased risk for subacromial impingement from the burden of suture knots. Arthroscopic knotless double row rotator cuff repair is a safe and effective method to repair rotator cuff tears.

  13. Evaluation of thoracic abnormalities on 64-row multi-detector row CT: Comparison between axial images versus coronal reformations

    Energy Technology Data Exchange (ETDEWEB)

    Nishino, Mizuki [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States)]. E-mail: mnishino@bidmc.harvard.edu; Kubo, Takeshi [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States); Kataoka, Milliam L. [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States); Gautam, Shiva [Department of General Clinical Research Center and Biometrics, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States); Raptopoulos, Vassilios [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States); Hatabu, Hiroto [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States)

    2006-07-15

    Purpose: To evaluate the capability of coronal reformations of chest on 64-row MDCT in demonstrating thoracic abnormalities in comparison with axial images. Materials and methods: Thirty-eight consecutive patients who underwent pulmonary CTA on 64-row MDCT were retrospectively studied with institutional review board (IRB) approval. Contiguous 2 mm axial and coronal images were reviewed independently with a 1-week interval, by consensus reading of two board-certified radiologists. Overall image quality was graded using a five-point scale. Abnormalities in mediastinum, hilum, pulmonary vessels, aorta, heart, esophagus, pleura, chest wall, and lung parenchyma were scored: 1 = definitely absent, 2 = probably absent, 3 = equivocal, 4 probably present, 5 = definitely present. Scores on axial and coronal images were compared using weighted {kappa} analysis. Results: Overall image quality was not different with statistical relevance between axial and coronal images (mean/median scores; 3.7/4; 3.6/4, respectively, P = 0.286, Wilcoxon signed-rank test). Significant agreement was observed between axial and coronal scores (mean weighted {kappa}, 0.661; range, 0.362-1). Agreement was almost perfect for pneumothorax, lung and pleural mass, effusion and consolidation (weighted {kappa} = 0.833-1); substantial for pulmonary embolism, trachea, mediastinal lymphadenopathy and non-skeletal chest wall lesion, heart, esophagus, and emphysema (weighted {kappa}, 0.618-0.799); moderate for atelectasis, mediastinum, hilar nodes, aorta, other lung lesions, skeletal chest wall lesions, linear scarring, nodules >1 cm, pulmonary artery abnormalities and pleural thickening (weighted {kappa}, 0.405-0.592); and fair for nodules <1 cm (weighted {kappa} = 0.362). Conclusion: Coronal reformations on 64-row MDCT had substantial agreement with axial images for evaluation of the majority of thoracic abnormalities.

  14. Evaluation of thoracic abnormalities on 64-row multi-detector row CT: Comparison between axial images versus coronal reformations

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Kubo, Takeshi; Kataoka, Milliam L.; Gautam, Shiva; Raptopoulos, Vassilios; Hatabu, Hiroto

    2006-01-01

    Purpose: To evaluate the capability of coronal reformations of chest on 64-row MDCT in demonstrating thoracic abnormalities in comparison with axial images. Materials and methods: Thirty-eight consecutive patients who underwent pulmonary CTA on 64-row MDCT were retrospectively studied with institutional review board (IRB) approval. Contiguous 2 mm axial and coronal images were reviewed independently with a 1-week interval, by consensus reading of two board-certified radiologists. Overall image quality was graded using a five-point scale. Abnormalities in mediastinum, hilum, pulmonary vessels, aorta, heart, esophagus, pleura, chest wall, and lung parenchyma were scored: 1 = definitely absent, 2 = probably absent, 3 = equivocal, 4 probably present, 5 = definitely present. Scores on axial and coronal images were compared using weighted κ analysis. Results: Overall image quality was not different with statistical relevance between axial and coronal images (mean/median scores; 3.7/4; 3.6/4, respectively, P = 0.286, Wilcoxon signed-rank test). Significant agreement was observed between axial and coronal scores (mean weighted κ, 0.661; range, 0.362-1). Agreement was almost perfect for pneumothorax, lung and pleural mass, effusion and consolidation (weighted κ = 0.833-1); substantial for pulmonary embolism, trachea, mediastinal lymphadenopathy and non-skeletal chest wall lesion, heart, esophagus, and emphysema (weighted κ, 0.618-0.799); moderate for atelectasis, mediastinum, hilar nodes, aorta, other lung lesions, skeletal chest wall lesions, linear scarring, nodules >1 cm, pulmonary artery abnormalities and pleural thickening (weighted κ, 0.405-0.592); and fair for nodules <1 cm (weighted κ = 0.362). Conclusion: Coronal reformations on 64-row MDCT had substantial agreement with axial images for evaluation of the majority of thoracic abnormalities

  15. Dose evaluation of narrow-beam

    International Nuclear Information System (INIS)

    Goto, Shinichi

    1999-01-01

    Reliability of the dose from the narrow photon beam becomes more important since the single high-dose rate radiosurgery becoming popular. The dose evaluation for the optimal dose is difficult due to absence of lateral electronic equilibrium. Data necessary for treatment regimen are TMR (tissue maximum ratio), OCR (off center ratio) and S c,p (total scatter factor). The narrow-beam was 10 MV X-ray from Varian Clinac 2100C equipped with cylindrical Fischer collimator CBI system. Detection was performed by Kodak XV-2 film, a PTW natural diamond detector M60003, Scanditronics silicon detector EDD-5 or Fujitec micro-chamber FDC-9.4C. Phantoms were the water equivalent one (PTW, RW3), water one (PTW, MP3 system) and Wellhofer WP600 system. Factors above were actually measured to reveal that in the dose evaluation of narrow photon beam, TMR should be measured by micro-chamber, OCR, by film, and S c,p , by the two. The use of diamond detector was recommended for more precise measurement and evaluation of the dose. The importance of water phantom in the radiosurgery system was also shown. (K.H.)

  16. Electron correlations in narrow band systems

    International Nuclear Information System (INIS)

    Kishore, R.

    1983-01-01

    The effect of the electron correlations in narrow bands, such as d(f) bands in the transition (rare earth) metals and their compounds and the impurity bands in doped semiconductors is studied. The narrow band systems is described, by the Hubbard Hamiltonian. By proposing a local self-energy for the interacting electron, it is found that the results are exact in both atomic and band limits and reduce to the Hartree Fock results for U/Δ → 0, where U is the intra-atomic Coulomb interaction and Δ is the bandwidth of the noninteracting electrons. For the Lorentzian form of the density of states of the noninteracting electrons, this approximation turns out to be equivalent to the third Hubbard approximation. A simple argument, based on the mean free path obtained from the imaginary part of the self energy, shows how the electron correlations can give rise to a discontinous metal-nonmetal transition as proposed by Mott. The band narrowing and the existence of the satellite below the Fermi energy in Ni, found in photoemission experiments, can also be understood. (Author) [pt

  17. Arthroscopic Double-Row Transosseous Equivalent Rotator Cuff Repair with a Knotless Self-Reinforcing Technique

    OpenAIRE

    Mook, William R.; Greenspoon, Joshua A.; Millett, Peter J.

    2016-01-01

    Background: Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. Methods: The preferred technique for rotator cuff repair of the senior author was reviewed and described in a step by step fashion. The final construct is a knotless double row transosseous equivalent construc...

  18. Ultra high resolution tomography

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, W.S.

    1994-11-15

    Recent work and results on ultra high resolution three dimensional imaging with soft x-rays will be presented. This work is aimed at determining microscopic three dimensional structure of biological and material specimens. Three dimensional reconstructed images of a microscopic test object will be presented; the reconstruction has a resolution on the order of 1000 A in all three dimensions. Preliminary work with biological samples will also be shown, and the experimental and numerical methods used will be discussed.

  19. Recent technologic advances in multi-detector row cardiac CT.

    Science.gov (United States)

    Halliburton, Sandra Simon

    2009-11-01

    Recent technical advances in multi-detector row CT have resulted in lower radiation dose, improved temporal and spatial resolution, decreased scan time, and improved tissue differentiation. Lower radiation doses have resulted from the use of pre-patient z collimators, the availability of thin-slice axial data acquisition, the increased efficiency of ECG-based tube current modulation, and the implementation of iterative reconstruction algorithms. Faster gantry rotation and the simultaneous use of two x-ray sources have led to improvements in temporal resolution, and gains in spatial resolution have been achieved through application of the flying x-ray focal-spot technique in the z-direction. Shorter scan times have resulted from the design of detector arrays with increasing numbers of detector rows and through the simultaneous use of two x-ray sources to allow higher helical pitch. Some improvement in tissue differentiation has been achieved with dual energy CT. This article discusses these recent technical advances in detail.

  20. Directional reflectance factor distributions of a cotton row crop

    Science.gov (United States)

    Kimes, D. S.; Newcomb, W. W.; Schutt, J. B.; Pinter, P. J., Jr.; Jackson, R. D.

    1984-01-01

    The directional reflectance factor distribution spanning the entire exitance hemisphere was measured for a cotton row crop (Gossypium barbadense L.) with 39 percent ground cover. Spectral directional radiances were taken in NOAA satellite 7 AVHRR bands 1 and 2 using a three-band radiometer with restricted 12 deg full angle field of view at half peak power points. Polar co-ordinate system plots of directional reflectance factor distributions and three-dimensional computer graphic plots of scattered flux were used to study the dynamics of the directional reflectance factor distribution as a function of spectral band, geometric structure of the scene, solar zenith and azimuth angles, and optical properties of the leaves and soil. The factor distribution of the incomplete row crops was highly polymodal relative to that for complete vegetation canopies. Besides the enhanced reflectance for the antisolar point, a reflectance minimum was observed towards the forwardscatter direction in the principle plane of the sun. Knowledge of the mechanics of the observed dynamics of the data may be used to provide rigorous validation for two- or three-dimensional radiative transfer models, and is important in interpreting aircraft and satellite data where the solar angle varies widely.

  1. [RESEARCH PROGRESS OF BIOMECHANICS OF PROXIMAL ROW CARPAL INSTABILITY].

    Science.gov (United States)

    Guo, Jinhai; Huang, Fuguo

    2015-01-01

    To review the research progress of the biomechanics of proximal row carpal instability (IPRC). The related literature concerning IPRC was extensively reviewed. The biomechanical mechanism of the surrounding soft tissue in maintaining the stability of the proximal row carpal (PRC) was analyzed, and the methods to repair or reconstruct the stability and function of the PRC were summarized from two aspects including basic biomechanics and clinical biomechanics. The muscles and ligaments of the PRC are critical to its stability. Most scholars have reached a consensus about biomechanical mechanism of the PRC, but there are still controversial conclusions on the biomechanics mechanism of the surrounding soft tissue to stability of distal radioulnar joint when the triangular fibrocartilage complex are damaged and the biomechanics mechanism of the scapholunate ligament. At present, there is no unified standard about the methods to repair or reconstruct the stability and function of the PRC. So, it is difficult for clinical practice. Some strides have been made in the basic biomechanical study on muscle and ligament and clinical biomechanical study on the methods to repair or reconstruct the stability and function of PRC, but it will be needed to further study the morphology of carpal articular surface and the adjacent articular surface, the pressure of distal carpals to proximal carpal and so on.

  2. Mastering Energy Management During Rowing Using Virtual Reality

    Directory of Open Access Journals (Sweden)

    Verbrugge Luc

    2011-12-01

    Full Text Available This study focused on one of the most important factors in rowing performance which is the ability demonstrated by elite rowers to regulate their effort during a 2000m race in order to produce their best performance. Experts are known to adopt a particular pacing strategy with a fast-start profile. The purpose of our study was to test by using virtual reality whether novice rowers were able to acquire this energy management skill during a 2000m race, with positive consequences for their rowing performance. Participants from the Avatar group were instructed to track a virtual boat, which velocity was previously calibrated to follow the appropriate to-be-learned velocity profile. This group was contrasted with a control group, which followed a classic training procedure. Our results indicate that the avatar group improved its performance (decrease in race duration, learned and maintained the expert profile. These effects were absent in the control group. Together, these results indicate that virtual reality can be used to accelerate the learning of energy-related skills.

  3. Radiological emergency room management with emphasis on multidetector-row

    Energy Technology Data Exchange (ETDEWEB)

    Philipp, M.O.; Kubin, K.; Hoermann, M.; Metz, V.M. E-mail: viktor.metz@univie.ac.at

    2003-10-01

    Trauma is the fifth leading cause of death after disease of the cardiovascular system, malignomas and disease of the respiratory and digestive system. The management of severely injured patients, including radiological imaging, is a matter of ongoing development. In particular, as for the imaging modalities, multidetector-row CT represents a substantial refinement in the diagnostic work-up of multitrauma patients. Sufficient therapy within the first hour after trauma increases the patient's chances for survival significantly. Thus, therapeutic procedures and diagnostic evaluation have to be concomitant events, performed by a multidisciplinary team, namely trauma surgeon, anesthesiologist and, last but not least, radiologist. The increased performance of multidetector-row CT leads to increased spatial resolution, which is a prerequisite for sophisticated two- and three-dimensional postprocessing. The increased volume coverage speed allows for comprehensive whole-body CT at still high levels of spatial resolution, resulting in significant spare of time which influences patient's survival. Using this technique conventional imaging such as plane film or angiography may be omitted.

  4. Development of Magnetorheological Resistive Exercise Device for Rowing Machine

    Directory of Open Access Journals (Sweden)

    Vytautas Grigas

    2016-01-01

    Full Text Available Training equipment used by professional sportsmen has a great impact on their sport performance. Most universal exercisers may help only to improve the general physical condition due to the specific kinematics and peculiar resistance generated by their loading units. Training of effective techniques and learning of psychomotor skills are possible only when exercisers conform to the movements and resistance typical for particular sports kinematically and dynamically. Methodology of developing a magnetorheological resistive exercise device for generating the desired law of passive resistance force and its application in a lever-type rowing machine are described in the paper. The structural parameters of a controllable hydraulic cylinder type device were found by means of the computational fluid dynamics simulation performed by ANSYS CFX software. Parameters describing the magnetorheological fluid as non-Newtonian were determined by combining numerical and experimental research of the resistance force generated by the original magnetorheological damper. A structural scheme of the device control system was developed and the variation of the strength of magnetic field that affects the magnetorheological fluid circulating in the device was determined, ensuring a variation of the resistance force on the oar handle adequate for the resistance that occurs during a real boat rowing stroke.

  5. Urbanization: the pipelines ROW (Right-of-Way) future

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Gilberto; Malzone, Vivian de Araujo Oliveira [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The accelerated process of urbanization that is shifting the aspects of Brazilian cities - most clearly in South East and South region states - is inherently involved with decayed levels of quality of life and little or any concern at all with the sustainability of such urban expansion. Besides the social difficulties generated from this non-planned growth - mainly in the cities' outskirts - there are many questions related to urbanization that should be reconsidered such as water, soil and air pollution; lack of water resources; floods, insufficient public transport and traffic problems; urban infra-structure and lodging privations and inadequate soil installment. This paper aims at showing how this disordered urban growth plays an important role on PETROBRAS' pipeline right of way located at the great cities urban areas, more specifically the Urban Right Of Way that cross the metropolitan region of the city of Sao Paulo. Also, it is an objective to express how such urbanization propitiate the execution of basic infra-structure in a way of integrating habitation, sanitation, environment and geotechnical sectors with the purposes of PETROBRAS of maintaining as priority the integrity of the pipelines located on the ROW as well as the integrity of these ROW themselves. (author)

  6. ULTRA-LIGHTWEIGHT CEMENT

    International Nuclear Information System (INIS)

    Fred Sabins

    2001-01-01

    The objective of this project is to develop an improved ultra-lightweight cement using ultralight hollow glass spheres (ULHS). Work reported herein addresses Task 1: Assess Ultra-Lightweight Cementing Problems and Task 3: Test Ultra-Lightweight Cements. Results reported this quarter include a review and summary of Halliburton Energy Services (HES) and BJ Services historical performance data for lightweight cement applications. These data are analyzed and compared to ULHS cement and foamed cement performances. Similar data is expected from Schlumberger, and an analysis of this data will be completed in the following phases of the project. Quality control testing of materials used to formulate ULHS cements in the laboratory was completed to establish baseline material performance standards. A testing protocol was developed employing standard procedures as well as procedures tailored to evaluate ULHS and foamed cement. This protocol is presented and discussed. Results of further testing of ULHS cements are presented along with an analysis to establish cement performance design criteria to be used during the remainder of the project. Finally, a list of relevant literature on lightweight cement performance is compiled for review during the next quarter

  7. Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material.

    Science.gov (United States)

    Baums, M H; Buchhorn, G H; Spahn, G; Poppendieck, B; Schultz, W; Klinger, H-M

    2008-11-01

    The aim of the study was to evaluate the time zero mechanical properties of single- versus double-row configuration for rotator cuff repair in an animal model with consideration of the stitch technique and suture material. Thirty-two fresh-frozen sheep shoulders were randomly assigned to four repair groups: suture anchor single-row repair coupled with (1) braided, nonabsorbable polyester suture sized USP No. 2 (SRAE) or (2) braided polyblend polyethylene suture sized No. 2 (SRAH). The double-row repair was coupled with (3) USP No. 2 (DRAE) or (4) braided polyblend polyethylene suture No. 2 (DRAH). Arthroscopic Mason-Allen stitches were used (single-row) and combined with medial horizontal mattress stitches (double-row). Shoulders were cyclically loaded from 10 to 180 N. Displacement to gap formation of 5- and 10-mm at the repair site, cycles to failure, and the mode of failure were determined. The ultimate tensile strength was verified in specimens that resisted to 3,000 cycles. DRAE and DRAH had a lower frequency of 5- (P = 0.135) and 10-mm gap formation (P = 0.135). All DRAE and DRAH resisted 3,000 cycles while only three SRAE and one SRAH resisted 3,000 cycles (P row specimens was significantly higher than in others (P 0.05). Double-row suture anchor repair with arthroscopic Mason-Allen/medial mattress stitches provides initial strength superior to single-row repair with arthroscopic Mason-Allen stitches under isometric cyclic loading as well as under ultimate loading conditions. Our results support the concept of double-row fixation with arthroscopic Mason-Allen/medial mattress stitches in rotator cuff tears with improvement of initial fixation strength and ultimate tensile load. Use of new polyblend polyethylene suture material seems not to increase the initial biomechanical aspects of the repair construct.

  8. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model.

    Science.gov (United States)

    Gajendran, Varun K; Szabo, Robert M; Myo, George K; Curtiss, Shane B

    2009-12-01

    Open or unstable metacarpal fractures frequently require open reduction and internal fixation. Locking plate technology has improved fixation of unstable fractures in certain settings. In this study, we hypothesized that there would be a difference in strength of fixation using double-row locking plates compared with single- and double-row non-locking plates in comminuted metacarpal fractures. We tested our hypothesis in a gap metacarpal fracture model simulating comminution using fourth-generation, biomechanical testing-grade composite sawbones. The metacarpals were divided into 6 groups of 15 bones each. Groups 1 and 4 were plated with a standard 6-hole, 2.3-mm plate in AO fashion. Groups 2 and 5 were plated with a 6-hole double-row 3-dimensional non-locking plate with bicortical screws aimed for convergence. Groups 3 and 6 were plated with a 6-hole double-row 3-dimensional locking plate with unicortical screws. The plated metacarpals were then tested to failure against cantilever apex dorsal bending (groups 1-3) and torsion (groups 4-6). The loads to failure in groups 1 to 3 were 198 +/- 18, 223 +/- 29, and 203 +/- 19 N, respectively. The torques to failure in groups 4 to 6 were 2,033 +/- 155, 3,190 +/- 235, and 3,161 +/- 268 N mm, respectively. Group 2 had the highest load to failure, whereas groups 5 and 6 shared the highest torques to failure (p row plates had equivalent bending and torsional stiffness, significantly higher than observed for the single-row non-locking plate. No other statistical differences were noted between groups. When subjected to the physiologically relevant forces of apex dorsal bending and torsion in a comminuted metacarpal fracture model, double-row 3-dimensional non-locking plates provided superior stability in bending and equivalent stability in torsion compared with double-row 3-dimensional locking plates, whereas single-row non-locking plates provided the least stability.

  9. Volumetric Synthetic Aperture Imaging with a Piezoelectric 2-D Row-Column Probe

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Engholm, Mathias; Christiansen, Thomas Lehrmann

    2016-01-01

    The synthetic aperture (SA) technique can be used for achieving real-time volumetric ultrasound imaging using 2-D row-column addressed transducers. This paper investigates SA volumetric imaging performance of an in-house prototyped 3 MHz λ/2-pitch 62+62 element piezoelectric 2-D row-column addres......The synthetic aperture (SA) technique can be used for achieving real-time volumetric ultrasound imaging using 2-D row-column addressed transducers. This paper investigates SA volumetric imaging performance of an in-house prototyped 3 MHz λ/2-pitch 62+62 element piezoelectric 2-D row...

  10. A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair.

    Science.gov (United States)

    Smith, Christopher D; Alexander, Susan; Hill, Adam M; Huijsmans, Pol E; Bull, Anthony M J; Amis, Andrew A; De Beer, Joe F; Wallace, Andrew L

    2006-11-01

    The optimal method for arthroscopic rotator cuff repair is not yet known. The hypothesis of the present study was that a double-row repair would demonstrate superior static and cyclic mechanical behavior when compared with a single-row repair. The specific aims were to measure gap formation at the bone-tendon interface under static creep loading and the ultimate strength and mode of failure of both methods of repair under cyclic loading. A standardized tear of the supraspinatus tendon was created in sixteen fresh cadaveric shoulders. Arthroscopic rotator cuff repairs were performed with use of either a double-row technique (eight specimens) or a single-row technique (eight specimens) with nonabsorbable sutures that were double-loaded on a titanium suture anchor. The repairs were loaded statically for one hour, and the gap formation was measured. Cyclic loading to failure was then performed. Gap formation during static loading was significantly greater in the single-row group than in the double-row group (mean and standard deviation, 5.0 +/- 1.2 mm compared with 3.8 +/- 1.4 mm; p row repairs failed at a mean of 320 +/- 96.9 N whereas the single-row repairs failed at a mean of 224 +/- 147.9 N (p = 0.058). Three single-row repairs and three double-row repairs failed as a result of suture cut-through. Four single-row repairs and one double-row repair failed as a result of anchor or suture failure. The remaining five repairs did not fail, and a midsubstance tear of the tendon occurred. Although more technically demanding, the double-row technique demonstrates superior resistance to gap formation under static loading as compared with the single-row technique. A double-row reconstruction of the supraspinatus tendon insertion may provide a more reliable construct than a single-row repair and could be used as an alternative to open reconstruction for the treatment of isolated tears.

  11. Muscle Synergies of Untrained Subjects during 6 min Maximal Rowing on Slides and Fixed Ergometer

    Directory of Open Access Journals (Sweden)

    Shazlin Shaharudin

    2014-12-01

    Full Text Available The slides ergometer (SE was an improvisation from fixed ergometer (FE to bridge the gap of mechanics between ergometer rowing and on-water rowing. The specific mechanical constraints of these two types of ergometers may affect the pattern of muscle recruitment, coordination and adaptation. The main purpose of this study was to evaluate the muscle synergy during 6 minutes maximal rowing on slides (SE and fixed ergometers (FE. The laterality of muscle synergy was also examined. Surface electromyography activity, power output, heart rate, stroke length and stroke rate were analyzed from nine physically active subjects to assess the rowing performance. Physically active subjects, who were not specifically trained in rowing, were chosen to exclude the training effect on muscle synergy. Principal component analysis (PCA with varimax rotation was applied to extract muscle synergy. Three muscle synergies were sufficient to explain the majority of variance in SE (94.4 ± 2.2 % and FE (92.8 ± 1.7 %. Subjects covered more rowing distance, exerted greater power output and attained higher maximal heart rate during rowing on SE than on FE. The results proved the flexibility of muscle synergy to adapt to the mechanical constraints. Rowing on SE emphasized on bi-articular muscles contrary to rowing on FE which relied on cumulative effect of trunk and upper limb muscles during propulsive phase.

  12. Analysis of straw row in the image to control the trajectory of the agricultural combine harvester

    Science.gov (United States)

    Shkanaev, Aleksandr Yurievich; Polevoy, Dmitry Valerevich; Panchenko, Aleksei Vladimirovich; Krokhina, Darya Alekseevna; Nailevish, Sadekov Rinat

    2018-04-01

    The paper proposes a solution to the automatic operation of the combine harvester along the straw rows by means of the images from the camera, installed in the cab of the harvester. The U-Net is used to recognize straw rows in the image. The edges of the row are approximated in the segmented image by the curved lines and further converted into the harvester coordinate system for the automatic operating system. The "new" network architecture and approaches to the row approximation has improved the quality of the recognition task and the processing speed of the frames up to 96% and 7.5 fps, respectively. Keywords: Grain harvester,

  13. COMPETITION AND FACILITATION EFFECTS OF DIFFERENTIAL INTRA-AND INTER-ROW WEED MANAGEMENT IN SUGARCANE

    OpenAIRE

    Martin , J; Chabalier , M; Letourmy , P; Chopart , J.-L; Arhiman , E; Marion , D

    2013-01-01

    International audience; Differential intra-and inter-row weed management can be a mean to reduce herbicide use in sugarcane. In 2011, a field experiment was conducted in La Reunion Island to assess inter-row weed competition. Four inter-row weed competition treatments for a duration of one (T1), two (T2), three (T3) and four (T4) months after planting were compared in a randomized complete block design with 5 replicates; treatment plots were paired with non-weeded inter-row control plots. All...

  14. Pool Boiling CHF in Inclined Narrow Annuli

    International Nuclear Information System (INIS)

    Kang, Myeong Gie

    2010-01-01

    Pool boiling heat transfer has been studied extensively since it is frequently encountered in various heat transfer equipment. Recently, it has been widely investigated in nuclear power plants for application to the advanced light water reactors designs. Through the review on the published results it can be concluded that knowledge on the combined effects of the surface orientation and a confined space on pool boiling heat transfer is of great practical importance and also of great academic interest. Fujita et al. investigated pool boiling heat transfer, from boiling inception to the critical heat flux (CHF, q' CHF ), in a confined narrow space between heated and unheated parallel rectangular plates. They identified that both the confined space and the surface orientation changed heat transfer much. Kim and Suh changed the surface orientation angles of a downward heating rectangular channel having a narrow gap from the downward-facing position (180 .deg.) to the vertical position (90 .deg.). They observed that the CHF generally decreased as the inclination angle (θ ) increased. Yao and Chang studied pool boiling heat transfer in a confined heat transfer for vertical narrow annuli with closed bottoms. They observed that when the gap size ( s ) of the annulus was decreased the effect of space confinement to boiling heat transfer increased. The CHF was occurred at much lower value for the confined space comparing to the unconfined pool boiling. Pool boiling heat transfer in narrow horizontal annular crevices was studied by Hung and Yao. They concluded that the CHF decreased with decreasing gap size of the annuli and described the importance of the thin film evaporation to explain the lower CHF of narrow crevices. The effect of the inclination angle on the CHF on countercurrent boiling in an inclined uniformly heated tube with closed bottoms was also studied by Liu et al. They concluded that the CHF reduced with the inclination angle decrease. A study was carried out

  15. Bridging suture makes consistent and secure fixation in double-row rotator cuff repair.

    Science.gov (United States)

    Fukuhara, Tetsutaro; Mihata, Teruhisa; Jun, Bong Jae; Neo, Masashi

    2017-09-01

    Inconsistent tension distribution may decrease the biomechanical properties of the rotator cuff tendon after double-row repair, resulting in repair failure. The purpose of this study was to compare the tension distribution along the repaired rotator cuff tendon among three double-row repair techniques. In each of 42 fresh-frozen porcine shoulders, a simulated infraspinatus tendon tear was repaired by using 1 of 3 double-row techniques: (1) conventional double-row repair (no bridging suture); (2) transosseous-equivalent repair (bridging suture alone); and (3) compression double-row repair (which combined conventional double-row and bridging sutures). Each specimen underwent cyclic testing at a simulated shoulder abduction angle of 0° or 40° on a material-testing machine. Gap formation and tendon strain were measured during the 1st and 30th cycles. To evaluate tension distribution after cuff repair, difference in gap and tendon strain between the superior and inferior fixations was compared among three double-row techniques. At an abduction angle of 0°, gap formation after either transosseous-equivalent or compression double-row repair was significantly less than that after conventional double-row repair (p row repair (p = 0.01) at 0° abduction had significantly less difference in gap formation between the superior and inferior fixations than did conventional double-row repair. After the 30th cycle, the difference in longitudinal strain between the superior and inferior fixations at 0° abduction was significantly less with compression double-row repair (2.7% ± 2.4%) than with conventional double-row repair (8.6% ± 5.5%, p = 0.03). Bridging sutures facilitate consistent and secure fixation in double-row rotator cuff repairs, suggesting that bridging sutures may be beneficial for distributing tension equally among all sutures during double-row repair of rotator cuff tears. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B

  16. Cervical spinal canal narrowing in idiopathic syringomyelia

    International Nuclear Information System (INIS)

    Struck, Aaron F.; Carr, Carrie M.; Shah, Vinil; Hesselink, John R.; Haughton, Victor M.

    2016-01-01

    The cervical spine in Chiari I patient with syringomyelia has significantly different anteroposterior diameters than it does in Chiari I patients without syringomyelia. We tested the hypothesis that patients with idiopathic syringomyelia (IS) also have abnormal cervical spinal canal diameters. The finding in both groups may relate to the pathogenesis of syringomyelia. Local institutional review boards approved this retrospective study. Patients with IS were compared to age-matched controls with normal sagittal spine MR. All subjects had T1-weighted spin-echo (500/20) and T2-weighted fast spin-echo (2000/90) sagittal cervical spine images at 1.5 T. Readers blinded to demographic data and study hypothesis measured anteroposterior diameters at each cervical level. The spinal canal diameters were compared with a Mann-Whitney U test. The overall difference was assessed with a Friedman test. Seventeen subjects were read by two reviewers to assess inter-rater reliability. Fifty IS patients with 50 age-matched controls were studied. IS subjects had one or more syrinxes varying from 1 to 19 spinal segments. Spinal canal diameters narrowed from C1 to C3 and then enlarged from C5 to C7 in both groups. Diameters from C2 to C4 were narrower in the IS group (p < 0.005) than in controls. The ratio of the C3 to the C7 diameters was also smaller (p = 0.004) in IS than controls. Collectively, the spinal canal diameters in the IS were significantly different from controls (Friedman test p < 0.0001). Patients with IS have abnormally narrow upper and mid cervical spinal canal diameters and greater positive tapering between C3 and C7. (orig.)

  17. Cervical spinal canal narrowing in idiopathic syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Struck, Aaron F. [Massachusetts General Hospital, Department of Neurology, Boston, MA (United States); Carr, Carrie M. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Shah, Vinil [University of California San Francisco, Department of Radiology, San Francisco, CA (United States); Hesselink, John R. [University of California San Diego, Department of Radiology, San Diego, CA (United States); Haughton, Victor M. [University of Wisconsin, Department of Radiology, Madison, WI (United States)

    2016-08-15

    The cervical spine in Chiari I patient with syringomyelia has significantly different anteroposterior diameters than it does in Chiari I patients without syringomyelia. We tested the hypothesis that patients with idiopathic syringomyelia (IS) also have abnormal cervical spinal canal diameters. The finding in both groups may relate to the pathogenesis of syringomyelia. Local institutional review boards approved this retrospective study. Patients with IS were compared to age-matched controls with normal sagittal spine MR. All subjects had T1-weighted spin-echo (500/20) and T2-weighted fast spin-echo (2000/90) sagittal cervical spine images at 1.5 T. Readers blinded to demographic data and study hypothesis measured anteroposterior diameters at each cervical level. The spinal canal diameters were compared with a Mann-Whitney U test. The overall difference was assessed with a Friedman test. Seventeen subjects were read by two reviewers to assess inter-rater reliability. Fifty IS patients with 50 age-matched controls were studied. IS subjects had one or more syrinxes varying from 1 to 19 spinal segments. Spinal canal diameters narrowed from C1 to C3 and then enlarged from C5 to C7 in both groups. Diameters from C2 to C4 were narrower in the IS group (p < 0.005) than in controls. The ratio of the C3 to the C7 diameters was also smaller (p = 0.004) in IS than controls. Collectively, the spinal canal diameters in the IS were significantly different from controls (Friedman test p < 0.0001). Patients with IS have abnormally narrow upper and mid cervical spinal canal diameters and greater positive tapering between C3 and C7. (orig.)

  18. Cancerogenesis Risks between 64 and 320 Row Detector CT for Coronary CTA Screening

    Directory of Open Access Journals (Sweden)

    Atif N Khan

    2014-01-01

    Full Text Available Objectives: This study compares cancerogenesis risks posed by the 64 row detector and the 320 row detector computed tomography scanners used during coronary computed tomography angiography (CCTA following decennial screening guidelines. Material and Methods: Data of the radiation absorbed after CCTA by lung, thyroid, and female breast in patients between 50 and 70 years of age obtained from prior published literature for the 64 row CT scanner were compared with data from our study using 320 row detector CT scanner. Data from the 64 row and the 320 row detector CT scanners was used to determine lifetime attributable risks (LAR of cancer based on the biological effects of ionizing radiation (BEIR VII report. Results: The relative reduction of LAR (% for 50-, 60-, and 70-year-old patients undergoing scanning with the 320 row detector CT scanner was 30% lower for lung, and more than 50% lower for female breast when compared with results from 64 row detector CT scanner. The use of 320 row detector CT would result in a combined cumulative cancer incidence of less than 1/500 for breast in women and less than 1/1000 for lung in men; By comparison, this is much lower than other more common risk factors: 16-fold for lung cancer in persistent smokers, 2-fold for breast cancer with a first degree family member history of breast cancer, and 10-fold for thyroid cancer with a family member with thyroid cancer. Decennial screening would benefit at least 355,000 patients from sudden cardiac death each year, 94% of whom have significant coronary artery disease, with at least one stenosis >75%. LAR for thyroid cancer was negligible for both scanners. Conclusion: Lung and female breast LAR reductions with 320 row detector compared with 64 row detector CT are substantial, and the benefits would outweigh increased cancer risks with decennial screening in the age group of 50-70 years.

  19. Volume dips; spot price ranges narrow

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    This article is the September 1994 uranium market summary. Volume in the spot concentrates market fell below 1 million lbs U3O8. In total, twelve deals took place compared to 28 deals in August. Of the twelve deals, three took place in the spot concentrates market, two took place in the medium and long-term market, three in the conversion market, and four in the enrichment market. Restricted prices weakened, but unrestricted prices firmed slightly. The enrichment price range narrowed a bit

  20. f-band narrowing in uranium intermetallics

    International Nuclear Information System (INIS)

    Dunlap, B.D.; Litterst, F.J.; Malik, S.K.; Kierstead, H.A.; Crabtree, G.W.; Kwok, W.; Lam, D.J.; Mitchell, A.W.

    1987-01-01

    Although the discovery of heavy fermion behavior in uranium compounds has attracted a great deal of attention, relatively little work has been done which is sufficiently systematic to allow an assessment of the relationship of such behavior to more common phenomena, such as mixed valence, narrow-band effects, etc. In this paper we report bulk property measurements for a number of alloys which form a part of such a systematic study. The approach has been to take relatively simple and well-understood materials and alter their behavior by alloying to produce heavy fermion or Kondo behavior in a controlled way

  1. Itinerant ferromagnetism in the narrow band limit

    CERN Document Server

    Liu, S H

    2000-01-01

    It is shown that in the narrow band, strong interaction limit the paramagnetic state of an itinerant ferromagnet is described by the disordered local moment state. As a result, the Curie temperature is orders of magnitude lower than what is expected from the large exchange splitting of the spin bands. An approximate analysis has also been carried out for the partially ordered state, and the result explains the temperature evolvement of the magnetic contributions to the resistivity and low-energy optical conductivity of CrO sub 2.

  2. Critical unpairing currents in narrow niobium films

    International Nuclear Information System (INIS)

    Gershenzon, M.E.; Gubankov, V.N.

    1979-01-01

    Investigated are the dependences of critical currents of narrow ( with the width of W=0.5-15 μm) superconducting niobium films on temperature and a magnetic field. The proposed method of film production with the width of the 1μm order and with small edge inhomogeneities ((<=500 A) permitted to realize the Ginsburg-Landau unpairing currents in the wide range of temperatures. The correct comparison with the theory showed that the unpairing currents are observed if W(< or approximately) 2delta, where delta is the effective depth of the penetration of the perpendicular magnetic field

  3. Narrow electron injector for ballistic electron spectroscopy

    International Nuclear Information System (INIS)

    Kast, M.; Pacher, C.; Strasser, G.; Gornik, E.

    2001-01-01

    A three-terminal hot electron transistor is used to measure the normal energy distribution of ballistic electrons generated by an electron injector utilizing an improved injector design. A triple barrier resonant tunneling diode with a rectangular transmission function acts as a narrow (1 meV) energy filter. An asymmetric energy distribution with its maximum on the high-energy side with a full width at half maximum of ΔE inj =10 meV is derived. [copyright] 2001 American Institute of Physics

  4. Narrow-Bicliques: Cryptanalysis of Full IDEA

    DEFF Research Database (Denmark)

    Khovratovich, D.; Leurent, G.; Rechberger, C.

    2012-01-01

    We apply and extend the recently introduced biclique framework to IDEA and for the first time describe an approach to noticeably speed-up key-recovery for the full 8.5 round IDEA.We also show that the biclique approach to block cipher cryptanalysis not only obtains results on more rounds, but also...... extended with ways to allow for a significantly reduced data complexity with everything else being equal. For this we use available degrees of freedom as known from hash cryptanalysis to narrow the relevant differential trails. Our cryptanalysis is of high computational complexity, and does not threaten...

  5. Biomechanical Performance of Medial Row Suture Placement Relative to the Musculotendinous Junction in Transosseous Equivalent Suture Bridge Double-Row Rotator Cuff Repair.

    Science.gov (United States)

    Virk, Mandeep S; Bruce, Benjamin; Hussey, Kristen E; Thomas, Jacqueline M; Luthringer, Tyler A; Shewman, Elizabeth F; Wang, Vincent M; Verma, Nikhil N; Romeo, Anthony A; Cole, Brian J

    2017-02-01

    To compare the biomechanical performance of medial row suture placement relative to the musculotendinous junction (MTJ) in a cadaveric transosseous equivalent suture bridge (TOE-SB) double-row (DR) rotator cuff repair (RCR) model. A TOE-SB DR technique was used to reattach experimentally created supraspinatus tendon tears in 9 pairs of human cadaveric shoulders. The medial row sutures were passed either near the MTJ (MTJ group) or 10 mm lateral to the MTJ (rotator cuff tendon [RCT] group). After the supraspinatus repair, the specimens underwent cyclic loading and load to failure tests. The localized displacement of the markers affixed to the tendon surface was measured with an optical tracking system. The MTJ group showed a significantly higher (P = .03) medial row failure (5/9; 3 during cyclic testing and 2 during load to failure testing) compared with the RCT group (0/9). The mean number of cycles completed during cyclic testing was lower in the MTJ group (77) compared with the RCT group (100; P = .07) because 3 specimens failed in the MTJ group during cyclic loading. There were no significant differences between the 2 study groups with respect to biomechanical properties during the load to failure testing. In a cadaveric TOE-SB DR RCR model, medial row sutures through the MTJ results in a significantly higher rate of medial row failure. In rotator cuff tears with tendon tissue loss, passage of medial row sutures through the MTJ should be avoided in a TOE-SB RCR technique because of the risk of medial row failure. Copyright © 2016. Published by Elsevier Inc.

  6. Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material

    OpenAIRE

    Baums, M. H.; Buchhorn, G. H.; Spahn, G.; Poppendieck, B.; Schultz, W.; Klinger, H.-M.

    2008-01-01

    The aim of the study was to evaluate the time zero mechanical properties of single- versus double-row configuration for rotator cuff repair in an animal model with consideration of the stitch technique and suture material. Thirty-two fresh-frozen sheep shoulders were randomly assigned to four repair groups: suture anchor single-row repair coupled with (1) braided, nonabsorbable polyester suture sized USP No. 2 (SRAE) or (2) braided polyblend polyethylene suture sized No. 2 (SRAH). The double-...

  7. MOTION CAPTURE AS A MODERN TECHNOLOGY FOR ANALYSING ERGOMETER ROWING

    Directory of Open Access Journals (Sweden)

    Maria Skublewska-Paszkowska

    2016-03-01

    Full Text Available The paper presents a purpose-built laboratory stand consisting of a Vicon motion capture system with reference video cameras, wireless EMG system, Concept 2 Indoor Rower ergometer, wireless heart rate monitor and the Nexus software. A pilot study of people who exercise on the ergometer helped to create a proper configuration of all the components of the laboratory. Moreover, a procedure for carrying out research was developed, which consists of several steps divided into 4 stages: preparation of the motion acquisition system; preparation of the participant; familiarising participants with the technique of rowing, recording their movements and acquiring other measurement signals. Preliminary analysis of the results obtained from heterogeneous signals from various devices showed that all the components of the research stand are mutually compatible and the received signals do not interfere with one another.

  8. Traumatic thoracic injury: the role of Multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Joo; Kang, Doo Kyung; Kim, Tae Hee [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2006-05-15

    The introduction of Multidetector-row CT (MDCT) has revolutionized the diagnostic strategy of multitrauma patients. The rapid acquisition of a large scanning volume with a thin slice collimation allows for motion-free images of high spatial resolution, and this enables the application of the multiplanar reformat (MPR) and 3D volume-rendering (VR) images. The MPR images more accurately demonstrate aortic rupture or dissection, diaphragmatic injuries and fracture of vertebrae, sternum and costal cartilages. Diagnosing vascular injuries can be aided by using the MIP images. Rib fracture, trachea and bronchial laceration are more easily detected by the 3D images, while airway and vascular injuries can be detected from performing virtual endoscopy. We introduce our current CT imaging protocol and we present our clinical experience with using MDCT in the assessment of patients with blunt thoracic trauma.

  9. Respiratory gated lung CT using 320-row area detector CT

    International Nuclear Information System (INIS)

    Sakamoto, Ryo; Noma, Satoshi; Higashino, Takanori

    2010-01-01

    Three hundred and twenty-row Area Detector CT (ADCT) has made it possible to scan whole lung field with prospective respiratory gated wide volume scan. We evaluated whether the respiratory gated wide volume scan enables to reduce motion induced artifacts in the lung area. Helical scan and respiratory gated wide volume scan were performed in 5 patients and 10 healthy volunteers under spontaneous breathing. Significant reduction of motion artifact and superior image quality were obtained in respiratory gated scan in comparison with helical scan. Respiratory gated wide volume scan is an unique method using ADCT, and is able to reduce motion artifacts in lung CT scans of patients unable to suspend respiration in clinical scenes. (author)

  10. 64-Row multidetector CT virtual hysterosalpingography. Findings in 2500 patients

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Capunay, Carlos; Baronio, Mariano; Vallejos, Javier; Papier, Sergio; Carrascosa, Jorge

    2011-01-01

    Objective. To depict typical features of virtual hysterosalpingography (VHSG) in infertile patients. Material and methods: 2500 VHSG performed using a 64-row MOCT were evaluated. Results: Cervical abnormalities visualized corresponded to parietal irregularities (21%); thickened folds (9%); polyps (11%); diverticula (5%); cervical strictures (8%), and synechiae (1.5%). At the level of uterine cavity, polyps (44%); submucous myomas (8%); intramural and subserosal fibroids (11%); synechiae (10%); malformations (10%); adenomyosis (4%), and cesarean section scar (3%). Unilateral hydrosalpinx (7%) and bilateral hydrosalpinx (2%). Tubal obstruction was reported in 6% of cases. The average radiation dose was 0.94 mSv. Eighty-four percent of the patients reported mild pain or no postoperative discomfort. Conclusions: The virtual hysterosalpingography allowed a proper assessment of the internal genital organs, providing useful diagnostic information on infertility and other gynecological disorders. It constitutes a virtually painless, low-dose radiation technique, besides being well tolerated by patients

  11. Multi-detector row computed tomography and blunt chest trauma

    International Nuclear Information System (INIS)

    Scaglione, Mariano; Pinto, Antonio; Pedrosa, Ivan; Sparano, Amelia; Romano, Luigia

    2008-01-01

    Blunt chest trauma is a significant source of morbidity and mortality in industrialized countries. The clinical presentation of trauma patients varies widely from one individual to another and ranges from minor reports of pain to shock. Knowledge of the mechanism of injury, the time of injury, estimates of motor vehicle accident velocity and deceleration, and evidence of associated injury to other systems are all salient features to provide for an adequate assessment of chest trauma. Multi-detector row computed tomography (MDCT) scanning and MDCT-angiography are being used more frequently in the diagnosis of patients with chest trauma. The high sensitivity of MDCT has increased the recognized spectrum of injuries. This new technology can be regarded as an extremely valuable adjunct to physical examination to recognize suspected and unsuspected blunt chest trauma

  12. Multidetector row CT for imaging the paediatric tracheobronchial tree

    International Nuclear Information System (INIS)

    Papaioannou, Georgia; Young, Carolyn; Owens, Catherine M.

    2007-01-01

    The introduction of multidetector row computed tomography (MDCT) scanners has altered the approach to imaging the paediatric thorax. In an environment where the rapid acquisition of CT data allows general hospitals to image children instead of referring them to specialist paediatric centres, it is vital that general radiologists have access to protocols appropriate for paediatric applications. Thus a dramatic reduction in the delivered radiation dose is ensured with optimal contrast bolus delivery and timing, and inappropriate repetition of the scans is avoided. This article focuses on the main principles of volumetric CT imaging that apply generically to all MDCT scanners. We describe the reconstruction techniques for imaging the paediatric thorax and the low-dose protocols used in our institution on a 16-slice detector CT scanner. Examples of the commonest clinical applications are also given. (orig.)

  13. Deterministic blade row interactions in a centrifugal compressor stage

    Science.gov (United States)

    Kirtley, K. R.; Beach, T. A.

    1991-01-01

    The three-dimensional viscous flow in a low speed centrifugal compressor stage is simulated using an average passage Navier-Stokes analysis. The impeller discharge flow is of the jet/wake type with low momentum fluid in the shroud-pressure side corner coincident with the tip leakage vortex. This nonuniformity introduces periodic unsteadiness in the vane frame of reference. The effect of such deterministic unsteadiness on the time-mean is included in the analysis through the average passage stress, which allows the analysis of blade row interactions. The magnitude of the divergence of the deterministic unsteady stress is of the order of the divergence of the Reynolds stress over most of the span, from the impeller trailing edge to the vane throat. Although the potential effects on the blade trailing edge from the diffuser vane are small, strong secondary flows generated by the impeller degrade the performance of the diffuser vanes.

  14. Ultra-precision bearings

    CERN Document Server

    Wardle, F

    2015-01-01

    Ultra-precision bearings can achieve extreme accuracy of rotation, making them ideal for use in numerous applications across a variety of fields, including hard disk drives, roundness measuring machines and optical scanners. Ultraprecision Bearings provides a detailed review of the different types of bearing and their properties, as well as an analysis of the factors that influence motion error, stiffness and damping. Following an introduction to basic principles of motion error, each chapter of the book is then devoted to the basic principles and properties of a specific type of bearin

  15. Dosimetry of narrow band UVB treatments

    International Nuclear Information System (INIS)

    Goode, D.H.; Mannering, D.M.

    1996-01-01

    Full text: For many years psoriasis has been treated with broad band UVB lamps. These lamps have a bell shaped spectrum which peaks at 305 nm and extends from 280 nm to 350 nm. However research with monochromatic UV radiation has shown that wavelengths between 300 nm and 320 nm are the most efficacious for clearing psoriasis while wavelengths below 305 nm are most effective for producing the undesirable side effect of erythema (sunburn). In response to these findings Philips developed a narrow band UVB tube in which a large fraction of the output was confined to a narrow peak (bandwidth 2.5 nm) situated at 311 nm. Christchurch Hospital replaced broad band UVB with narrow band treatments in August 1995 and as this required UV exposures to be substantially increased new protocols had to be developed. Three aspects needed to be addressed. These were translating the dose from broad band to narrow band for current patients, determining the initial dose for new patients and developing a formula for increasing subsequent exposures to both types of patient. To translate doses the spectral irradiance (μW/cm 2 /nm) that would fall on the patient was measured in both the old broad band and the new narrow band treatment units and from this UV doses were calculated. All doses were expressed in mJ/cm 2 of unweighted UV over the range 250 nm to 400 nm. The erythemal effectiveness of the two units were compared by using the CIE 1987 curve to express doses in terms of the equivalent exposure of monochromatic 297 nm radiation. It was found that an exposure of 3.96 mJ/cm 2 from the broad band FS40 tubes and 12.79 mJ/cm 2 from the narrow band TL/01 tubes were both equivalent to 1.00 mJ/cm 2 of monochromatic 297 nm radiation so when transferring patients all broad band doses needed to be increased by a factor of 3.2. Before transferring any patients this factor was confirmed by conducting two minimal erythema dose (MED) tests on a normal subject, one in each unit. For new patients a

  16. A methodology to enlarge narrow stability windows

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Ewerton M.P.; Pastor, Jorge A.S.C.; Fontoura, Sergio A.B. [Pontificia Univ. Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. de Engenharia Civil. Grupo de Tecnologia e Engenharia de Petroleo

    2004-07-01

    The stability window in a wellbore design is defined by the difference between fracture pressure and collapse pressure. Deep water environments typically present narrow stability windows, because rocks have low strength due to under-compaction process. Often also, horizontal wells are drilled to obtain a better development of reservoirs placed in thin layers of sandstone. In this scenario, several challenges are faced when drilling in deep water. The traditional approach for predicting instabilities is to determine collapses and fractures at borehole wall. However, the initiation of rupture does not indicate that the borehole fails to perform its function as a wellbore. Thus, a methodology in which the stability window may be enlarged is desirable. This paper presents one practical analytical methodology that consists in allowing wellbore pressures smaller than the conventional collapse pressure, i.e., based upon failure on the borehole wall. This means that a collapse region (shear failure) will be developed around the borehole wall. This collapse region is pre-defined and to estimate its size is used a failure criterion. The aforementioned methodology is implemented in a user-friendly software, which can perform analyses of stress, pore pressure, formation failure, mud weight and mud salinity design for drilling in shale formations. Simulations of a wellbore drilling in a narrow stability window environment are performed to demonstrate the improvements of using the methodology. (author)

  17. Narrow resonances and short-range interactions

    International Nuclear Information System (INIS)

    Gelman, Boris A.

    2009-01-01

    Narrow resonances in systems with short-range interactions are discussed in an effective field theory (EFT) framework. An effective Lagrangian is formulated in the form of a combined expansion in powers of a momentum Q 0 | 0 --a resonance peak energy. At leading order in the combined expansion, a two-body scattering amplitude is the sum of a smooth background term of order Q 0 and a Breit-Wigner term of order Q 2 (δε) -1 which becomes dominant for δε 3 . Such an EFT is applicable to systems in which short-distance dynamics generates a low-lying quasistationary state. The EFT is generalized to describe a narrow low-lying resonance in a system of charged particles. It is shown that in the case of Coulomb repulsion, a two-body scattering amplitude at leading order in a combined expansion is the sum of a Coulomb-modified background term and a Breit-Wigner amplitude with parameters renormalized by Coulomb interactions.

  18. Optical properties of vacuum deposited polyaniline ultra-thin film

    International Nuclear Information System (INIS)

    Wahab, M. R. A.; Din, M.; Yunus, W. M. M.; Hasan, Z. A.; Kasim, A.

    2005-01-01

    Full text: Ultra-thin films of emeraldine base (EB) and emeraldine salt (ES) form of polyaniline (PANi) were prepared using electron-gun vacuum deposition. Thickness range studied was between 100AA and 450AA. Dielectric permittivity of the films determined from Kretchmann Configuration Surface Plasmon Resonance (SPR) angles-scanning set-up show shifts and narrowing of the SPR dip. Absorbance spectra of S-polarized and P-polarized light show the aging effect on orientation of the film. The effect of aging on its conductivity and photoluminescence is also correlated to the surface morphology

  19. Influence of Inter and Intra-rows Spacing on Yield and Yield ...

    African Journals Online (AJOL)

    Abyssinia

    yield and yield components of fresh market(Bishola) and processing (Cochoro) tomato cultivars. ... row spacing had a significant effect on plan canopy width, above ground dry biomass, ... Poor varietal performance and management practices that includeinter and intra-row spacing ..... of assimilate export from the leaves.

  20. Response of rainfed chickpea (cicer arietnum L.) to tween row spatial arrangement at multiple densities

    International Nuclear Information System (INIS)

    Erdogan, C.

    2014-01-01

    Plant density and arrangement are important factors affecting rainfed chickpea yield. A field experiment was conducted under the Eastern Mediterranean conditions for two consecutive growing seasons (2009-2010 and 2010-2011) to evaluate the effects of plant density (20, 25, 35 and 55 plants per m 2) and spatial configuration (conventional single 36-cm row width vs 18-cm twin rows spaced 72-cm between paired-rows). The experiment was laid out in a randomized complete block design in a factorial arrangement with three replications. Light interception (LI) and leaf area index (LAI) were significantly affected by plant density. Twin-row arrangement had higher light interception efficiency (LIE) than the single-row. Plants grown in the higher plant densities had greater LAI and LI; however, they had inefficient use of incident solar radiation. The number of primary branches was significantly affected by both planting patterns and plant densities, but the number of secondary branches was significantly affected only by the plant densities. The number of pods and seeds/plant decreased with the increasing plant density. The highest seed weight/plant was recorded at the lowest density (20 plants/m2) while the lowest one was recorded at the highest plant density (55 plants/m2). Seed weight and harvest index in the twin row were significantly higher in tween row than in the single row. (author)

  1. Single- and double-row repair for rotator cuff tears - biology and mechanics.

    Science.gov (United States)

    Papalia, Rocco; Franceschi, Francesco; Vasta, Sebastiano; Zampogna, Biagio; Maffulli, Nicola; Denaro, Vincenzo

    2012-01-01

    We critically review the existing studies comparing the features of single- and double-row repair, and discuss suggestions about the surgical indications for the two repair techniques. All currently available studies comparing the biomechanical, clinical and the biological features of single and double row. Biomechanically, the double-row repair has greater performances in terms of higher initial fixation strength, greater footprint coverage, improved contact area and pressure, decreased gap formation, and higher load to failure. Results of clinical studies demonstrate no significantly better outcomes for double-row compared to single-row repair. Better results are achieved by double-row repair for larger lesions (tear size 2.5-3.5 cm). Considering the lack of statistically significant differences between the two techniques and that the double row is a high cost and a high surgical skill-dependent technique, we suggest using the double-row technique only in strictly selected patients. Copyright © 2012 S. Karger AG, Basel.

  2. Vision-GPS Fusion for Guidance of an Autonomous Vehicle in Row Crops

    DEFF Research Database (Denmark)

    Bak, Thomas

    2001-01-01

    This paper presents a real-time localization system for an autonomous vehicle passing through 0.25 m wide crop rows at 6 km/h. Localization is achieved by fusion of mea-surements from a row guidance sensor and a GPS receiver. Conventional agricultural practice applies inputs such as herbicide...

  3. A parallel row-based algorithm for standard cell placement with integrated error control

    Science.gov (United States)

    Sargent, Jeff S.; Banerjee, Prith

    1989-01-01

    A new row-based parallel algorithm for standard-cell placement targeted for execution on a hypercube multiprocessor is presented. Key features of this implementation include a dynamic simulated-annealing schedule, row-partitioning of the VLSI chip image, and two novel approaches to control error in parallel cell-placement algorithms: (1) Heuristic Cell-Coloring; (2) Adaptive Sequence Length Control.

  4. Drag and power-loss in rowing due to velocity fluctuations

    NARCIS (Netherlands)

    Greidanus, A.J.; Delfos, R.; Westerweel, J.; Jansen, A.J.

    2016-01-01

    The flow motions in the turbulent boundary layer between water and a rowing boat initiate a turbulent skin friction. Reducing this skin friction results in better rowing performances. A Taylor-Couette (TC) facility was used to verify the power losses due to velocity fluctuations PV′ in

  5. Spray deposition inside multiple-row nursery trees with a laser-guided sprayer

    Science.gov (United States)

    Multiple-row container-grown trees require specially designed sprayers to achieve efficient spray delivery quality. A five-port air-assisted sprayer with both automatic and manual control modes was developed to discharge adequate spray deposition inside multiple-row tree plants. The sprayer resulted...

  6. Building Generalized Inverses of Matrices Using Only Row and Column Operations

    Science.gov (United States)

    Stuart, Jeffrey

    2010-01-01

    Most students complete their first and only course in linear algebra with the understanding that a real, square matrix "A" has an inverse if and only if "rref"("A"), the reduced row echelon form of "A", is the identity matrix I[subscript n]. That is, if they apply elementary row operations via the Gauss-Jordan algorithm to the partitioned matrix…

  7. Biomechanical advantages of triple-loaded suture anchors compared with double-row rotator cuff repairs.

    Science.gov (United States)

    Barber, F Alan; Herbert, Morley A; Schroeder, F Alexander; Aziz-Jacobo, Jorge; Mays, Matthew M; Rapley, Jay H

    2010-03-01

    To evaluate the strength and suture-tendon interface security of various suture anchors triply and doubly loaded with ultrahigh-molecular weight polyethylene-containing sutures and to evaluate the relative effectiveness of placing these anchors in a single-row or double-row arrangement by cyclic loading and then destructive testing. The infraspinatus muscle was reattached to the original humeral footprint by use of 1 of 5 different repair patterns in 40 bovine shoulders. Two single-row repairs and three double-row repairs were tested. High-strength sutures were used for all repairs. Five groups were studied: group 1, 2 triple-loaded screw suture anchors in a single row with simple stitches; group 2, 2 triple-loaded screw anchors in a single row with simple stitches over a fourth suture passed perpendicularly ("rip-stop" stitch); group 3, 2 medial and 2 lateral screw anchors with a single vertical mattress stitch passed from the medial anchors and 2 simple stitches passed from the lateral anchors; group 4, 2 medial double-loaded screw anchors tied in 2 mattress stitches and 2 push-in lateral anchors capturing the medial sutures in a "crisscross" spanning stitch; and group 5, 2 medial double-loaded screw anchors tied in 2 mattress stitches and 2 push-in lateral anchors creating a "suture-bridge" stitch. The specimens were cycled between 10 and 180 N at 1.0 Hz for 3,500 cycles or until failure. Endpoints were cyclic loading displacement (5 and 10 mm), total displacement, and ultimate failure load. A single row of triply loaded anchors was more resistant to stretching to a 5- and 10-mm gap than the double-row repairs with or without the addition of a rip-stop suture (P row repair (P row created by 2 medial double-loaded suture anchors and 2 lateral push-in anchors stretched more than any other group (P row repairs with either crossing sutures or 4 separate anchor points were more likely to fail (5- or 10-mm gap) than a single-row repair loaded with 3 simple sutures

  8. Significance of agricultural row structure on the microwave emissivity of soils

    Science.gov (United States)

    Promes, P. M.; Jackson, T. J.; O'Neill, P. E.

    1987-01-01

    A series of field experiments was carried out to extend the data base available for verifying agricultural row effect models of emissivity. The row effects model was used to simulate a data base from which an algorithm could be developed to account for row effects when the scene dielectric constant and small-scale roughness are unknown. One objective of the study was to quantify the significance of row structure and to develop a practical procedure for removing the effects of periodic row structure on the microwave emissivity of a soil in order to use the emissivity values to estimate the soil moisture. A second objective was to expand the data set available for model verification through field observations using a truck-mounted 1.4-GHz microwave radiometer.

  9. The team from ALICE DAQ (Data acquisition) involved in the 7th ALICE data challenge. First row: Sylvain Chapeland, Ulrich Fuchs, Pierre Vande Vyvre, Franco Carena Second row: Wisla Carena, Irina MAKHLYUEVA , Roberto Divia

    CERN Multimedia

    Claudia Marcelloni

    2007-01-01

    The team from ALICE DAQ (Data acquisition) involved in the 7th ALICE data challenge. First row: Sylvain Chapeland, Ulrich Fuchs, Pierre Vande Vyvre, Franco Carena Second row: Wisla Carena, Irina MAKHLYUEVA , Roberto Divia

  10. Production ultra propre

    CERN Document Server

    Morvan, Gilles

    2011-01-01

    L'ultra propreté se caractérise par l'absence de particules et la maîtrise de la contamination dans un environnement défini. Largement appliquée dans diverses industries (pharmacie, cosmétiques, dispositifs médicaux, chimie fine, biotechnologies, électronique et secteurs de pointe, agroalimentaire, plasturgie…), la technicité dans ce domaine est élevée, car principalement liée à la maîtrise des différentes sources de contaminations (eau, air ambiant, fluides, etc.). Véritable guide pratique, cet ouvrage détaille les points techniques essentiels pour permettre à l’ingénieur de trouver des solutions adéquates à chaque type de projet. La démarche passe par la rédaction de spécifications rigoureuses pour : - l’eau, essentielle à toutes productions, - les équipements de production ultra propre, - la démarche qualité et environnementale, - la démarche de suivi du projet.

  11. Don't rock the boat: how antiphase crew coordination affects rowing.

    Directory of Open Access Journals (Sweden)

    Anouk J de Brouwer

    Full Text Available It is generally accepted that crew rowing requires perfect synchronization between the movements of the rowers. However, a long-standing and somewhat counterintuitive idea is that out-of-phase crew rowing might have benefits over in-phase (i.e., synchronous rowing. In synchronous rowing, 5 to 6% of the power produced by the rower(s is lost to velocity fluctuations of the shell within each rowing cycle. Theoretically, a possible way for crews to increase average boat velocity is to reduce these fluctuations by rowing in antiphase coordination, a strategy in which rowers perfectly alternate their movements. On the other hand, the framework of coordination dynamics explicates that antiphase coordination is less stable than in-phase coordination, which may impede performance gains. Therefore, we compared antiphase to in-phase crew rowing performance in an ergometer experiment. Nine pairs of rowers performed a two-minute maximum effort in-phase and antiphase trial at 36 strokes min(-1 on two coupled free-floating ergometers that allowed for power losses to velocity fluctuations. Rower and ergometer kinetics and kinematics were measured during the trials. All nine pairs easily acquired antiphase rowing during the warm-up, while one pair's coordination briefly switched to in-phase during the maximum effort trial. Although antiphase interpersonal coordination was indeed less accurate and more variable, power production was not negatively affected. Importantly, in antiphase rowing the decreased power loss to velocity fluctuations resulted in more useful power being transferred to the ergometer flywheels. These results imply that antiphase rowing may indeed improve performance, even without any experience with antiphase technique. Furthermore, it demonstrates that although perfectly synchronous coordination may be the most stable, it is not necessarily equated with the most efficient or optimal performance.

  12. Single-row modified mason-allen versus double-row arthroscopic rotator cuff repair: a biomechanical and surface area comparison.

    Science.gov (United States)

    Nelson, Cory O; Sileo, Michael J; Grossman, Mark G; Serra-Hsu, Frederick

    2008-08-01

    The purpose of this study was to compare the time-zero biomechanical strength and the surface area of repair between a single-row modified Mason-Allen rotator cuff repair and a double-row arthroscopic repair. Six matched pairs of sheep infraspinatus tendons were repaired by both techniques. Pressure-sensitive film was used to measure the surface area of repair for each configuration. Specimens were biomechanically tested with cyclic loading from 20 N to 30 N for 20 cycles and were loaded to failure at a rate of 1 mm/s. Failure was defined at 5 mm of gap formation. Double-row suture anchor fixation restored a mean surface area of 258.23 +/- 69.7 mm(2) versus 148.08 +/- 75.5 mm(2) for single-row fixation, a 74% increase (P = .025). Both repairs had statistically similar time-zero biomechanics. There was no statistical difference in peak-to-peak displacement or elongation during cyclic loading. Single-row fixation showed a higher mean load to failure (110.26 +/- 26.4 N) than double-row fixation (108.93 +/- 21.8 N). This was not statistically significant (P = .932). All specimens failed at the suture-tendon interface. Double-row suture anchor fixation restores a greater percentage of the anatomic footprint when compared with a single-row Mason-Allen technique. The time-zero biomechanical strength was not significantly different between the 2 study groups. This study suggests that the 2 factors are independent of each other. Surface area and biomechanical strength of fixation are 2 independent factors in the outcome of rotator cuff repair. Maximizing both factors may increase the likelihood of complete tendon-bone healing and ultimately improve clinical outcomes. For smaller tears, a single-row modified Mason-Allen suture technique may provide sufficient strength, but for large amenable tears, a double row can provide both strength and increased surface area for healing.

  13. Analysis of narrow effects in pp annihilations

    CERN Document Server

    Defoix, C

    1972-01-01

    The author describes briefly some methods of analysis that final states involving a number of like particles require. A first method consists of separating two competing channels to minimize the reflections due to the undesirable one. Later techniques of analysis lead to the isolation of the only channel of interest and circumvention of the problems of background and reflections due to irrelevant final states. Generally, all these processes are based on the presence of a narrow and identified resonance, for example the eta /sup 0/ or omega /sup 0/ ( to pi /sup +/ pi /sup -/ pi /sup 0/). To be efficient, it is necessary that the observed width of such a basic resonance not be increased too much by experimental errors. (6 refs).

  14. Search for narrow four-baryon states

    International Nuclear Information System (INIS)

    Badelek, B.

    1981-01-01

    Highly excited (4.10 2 ) four-baryon resonances have been searched for in the missing-mass spectrum of the reaction π - + 4 He → π - + X at 5 GeV/c in the region of small four-momentum transfer (0.005 2 ), where one of the decay products of the X is either proton or deuteron or triton. No resonance signal is seen in the mass spectrum of X. Within our limited acceptance, the cross section for the production of a narrow (GAMMA approx. 20 MeV/c 2 ) four-baryon state with mass 4.9 GeV/c 2 is estimated to be smaller than approx. 100 nb. (orig.)

  15. Active Brownian motion in a narrow channel

    Science.gov (United States)

    Ao, X.; Ghosh, P. K.; Li, Y.; Schmid, G.; Hänggi, P.; Marchesoni, F.

    2014-12-01

    We review recent advances in rectification control of artificial microswimmers, also known as Janus particles, diffusing along narrow, periodically corrugated channels. The swimmer self-propulsion mechanism is modeled so as to incorporate a nonzero torque (propulsion chirality). We first summarize the effects of chirality on the autonomous current of microswimmers freely diffusing in channels of different geometries. In particular, left-right and upside-down asymmetric channels are shown to exhibit different transport properties. We then report new results on the dependence of the diffusivity of chiral microswimmers on the channel geometry and their own self-propulsion mechanism. The self-propulsion torque turns out to play a key role as a transport control parameter.

  16. The effect of narrow provider networks on health care use.

    Science.gov (United States)

    Atwood, Alicia; Lo Sasso, Anthony T

    2016-12-01

    Network design is an often overlooked aspect of health insurance contracts. Recent policy factors have resulted in narrower provider networks. We provide plausibly causal evidence on the effect of narrow network plans offered by a large national health insurance carrier in a major metropolitan market. Our econometric design exploits the fact that some firms offer a narrow network plan to their employees and some do not. Our results show that narrow network health plans lead to reductions in health care utilization and spending. We find evidence that narrow networks save money by selecting lower cost providers into the network. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Colin Rowe y el equilibrio dinámico

    Directory of Open Access Journals (Sweden)

    Pablo López Martín

    2015-05-01

    Full Text Available ResumenEn 1944 Gyorgy Kepes publica el que sin duda será su texto más influyente, El lenguaje de la visión. En él Kepes trata de llevar a cabo una guía que explique la gramática y la sintaxis del fenómeno de la visión, y que sirva como herramienta para enfrentarse al arte como experiencia puramente sensorial, desprovista de toda carga literaria, semántica o sentimental.De todos los conceptos que Kepes desgrana en su ensayo quizá el más determinante de todos sea el denominado como equilibrio dinámico y que aparece por primera vez en esta obra . Este término logra verbalizar algo que estaba en el aire, orbitando alrededor de toda la plástica moderna, pero que hasta el momento sólo había sido explicado de forma empírica.En Colin Rowe reverbera la lectura reciente de las ideas kepesianas cuando escribe sus artículos Transparencia literal y fenomenal y Neo-“clasicismo” y arquitectura moderna I y II tratando de poner en evidencia los principios fundacionales del movimiento moderno que negaban la dimensión plástica de la disciplina . El artículo tratará sacar de a la luz y explicar esta influencia. AbstractIn 1944 Gyorgy Kepes published what undoubtless will be his most influential text, "The language of vision". What Kepes tried to do was a guide of grammar and syntax of vision, which allows to face art as purely sensory experience or just visual, devisted of any literary , semantic or sentimental meaning.Among all the concepts that Kepes developes in his essay perhaps the most decisive one is the so called dynamic equilibrium, which is introduced in this work for fi rst time, verbalizing something that was in the air, orbiting around the entire modern plastic but far only explained in an empirical way.Colin Rowe reverberates the recent readed kepesian ideas on his own writings Transparency: Literal and Phenomenal and Neo-'Classicism' and Modern Architecture I and II, when the author tries to highlight the founding

  18. 78 FR 25572 - Special Local Regulation; Wy-Hi Rowing Regatta, Trenton Channel; Detroit River, Wyandotte, MI

    Science.gov (United States)

    2013-05-02

    ...-AA08 Special Local Regulation; Wy-Hi Rowing Regatta, Trenton Channel; Detroit River, Wyandotte, MI..., during, and immediately after the Wy-Hi Rowing Regatta. This special local regulation will establish... to read as follows: Sec. 100.T09-0287 Special Local Regulation; Wy-Hi Rowing Regatta, Wyandotte, MI...

  19. Volume and crown characteristics of juvenile loblolly pine grown at various ratios of between and within row spacings

    Science.gov (United States)

    John R. Britt; Jason P. Reynolds

    2013-01-01

    In plantation forestry, several silvicultural treatments can be row oriented. When rows are treated individually, planting trees in wider rows may result in lower silvicultural treatment cost, facilitate future operations, such as thinning and fire fighting, and provide a longer period with open canopy conditions. All these scenarios could provide benefit to landowners...

  20. Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields.

    Science.gov (United States)

    Ben Daya, Ibrahim; Chen, Albert I H; Shafiee, Mohammad Javad; Wong, Alexander; Yeow, John T W

    2017-09-06

    The row-column method received a lot of attention for 3-D ultrasound imaging. By reducing the number of connections required to address the 2-D array and therefore reducing the amount of data to handle, this addressing method allows for real time 3-D imaging. Row-column still has its limitations: the issues of sparsity, speckle noise inherent to ultrasound, the spatially varying point spread function, and the ghosting artifacts inherent to the row-column method must all be taken into account when building a reconstruction framework. In this research, we build on a previously published system and propose an edge-guided, compensated row-column ultrasound imaging system that incorporates multilayered edge-guided stochastically fully connected conditional random fields to address the limitations of the row-column method. Tests carried out on simulated and real row-column ultrasound images show the effectiveness of our proposed system over other published systems. Visual assessment show our proposed system's potential at preserving edges and reducing speckle. Quantitative analysis shows that our proposed system outperforms previously published systems when evaluated with metrics such as Peak Signal-to-Noise Ratio, Coefficient of Correlation, and Effective Number of Looks. These results show the potential of our proposed system as an effective tool for enhancing 3-D row-column imaging.

  1. The effect of row structure on soil moisture retrieval accuracy from passive microwave data.

    Science.gov (United States)

    Xingming, Zheng; Kai, Zhao; Yangyang, Li; Jianhua, Ren; Yanling, Ding

    2014-01-01

    Row structure causes the anisotropy of microwave brightness temperature (TB) of soil surface, and it also can affect soil moisture retrieval accuracy when its influence is ignored in the inversion model. To study the effect of typical row structure on the retrieved soil moisture and evaluate if there is a need to introduce this effect into the inversion model, two ground-based experiments were carried out in 2011. Based on the observed C-band TB, field soil and vegetation parameters, row structure rough surface assumption (Q p model and discrete model), including the effect of row structure, and flat rough surface assumption (Q p model), ignoring the effect of row structure, are used to model microwave TB of soil surface. Then, soil moisture can be retrieved, respectively, by minimizing the difference of the measured and modeled TB. The results show that soil moisture retrieval accuracy based on the row structure rough surface assumption is approximately 0.02 cm(3)/cm(3) better than the flat rough surface assumption for vegetated soil, as well as 0.015 cm(3)/cm(3) better for bare and wet soil. This result indicates that the effect of row structure cannot be ignored for accurately retrieving soil moisture of farmland surface when C-band is used.

  2. Direction-specific recruitment of rotator cuff muscles during bench press and row.

    Science.gov (United States)

    Wattanaprakornkul, Duangjai; Halaki, Mark; Cathers, Ian; Ginn, Karen A

    2011-12-01

    Recent studies indicate that rotator cuff (RC) muscles are recruited in a reciprocal, direction-specific pattern during shoulder flexion and extension exercises. The main purpose of this study was to determine if similar reciprocal RC recruitment occurs during bench press (flexion-like) and row (extension-like) exercises. In addition, shoulder muscle activity was comprehensively compared between bench press and flexion; row and extension; and bench press and row exercises. Electromyographic (EMG) activity was recorded from 9 shoulder muscles sites in 15 normal volunteers. All exercises were performed at 20, 50 and 70% of subjects' maximal load. EMG data were normalized to standard maximal voluntary contractions. Infraspinatus activity was significantly higher than subscapularis during bench press, with the converse pattern during the row exercise. Significant differences in activity levels were found in pectoralis major, deltoid and trapezius between the bench press and flexion exercises and in lower trapezius between the row and extension exercises. During bench press and row exercises, the recruitment pattern in each active muscle did not vary with load. During bench press and row exercises, RC muscles contract in a reciprocal direction-specific manner in their role as shoulder joint dynamic stabilizers to counterbalance antero-posterior translation forces. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Evaluation of native bees as pollinators of cucurbit crops under floating row covers.

    Science.gov (United States)

    Minter, Logan M; Bessin, Ricardo T

    2014-10-01

    Production of cucurbit crops presents growers with numerous challenges. Several severe pests and diseases can be managed through the use of rotation, trap cropping, mechanical barriers, such as row covers, and chemical applications. However, considerations must also be made for pollinating insects, as adequate pollination affects the quantity and quality of fruit. Insecticides may negatively affect pollinators; a concern enhanced in recent years due to losses in managed Apis melifera L. colonies. Row covers can be used in place of chemical control before pollination, but when removed, pests have access to fields along with the pollinators. If pollination services of native bees could be harnessed for use under continuous row covers, both concerns could be balanced for growers. The potential of two bee species which specialize on cucurbit flowers, Peponapis pruinosa Say and Xenoglossa strenua Cresson, were assessed under continuous row covers, employed over acorn squash. Experimental treatments included plots with either naturally or artificially introduced bees under row covers and control plots with row covers either permanently removed at crop flowering, or employed continuously with no added pollinating insects. Pests in plots with permanently removed row covers were managed using standard practices used in certified organic production. Marketable yields from plots inoculated with bees were indistinguishable from those produced under standard practices, indicating this system would provide adequate yields to growers without time and monetary inputs of insecticide applications. Additionally, application of this technique was investigated for muskmelon production and discussed along with considerations for farm management.

  4. Does management intensity in inter rows effect soil physical properties in Austrian and Romanian vineyards?

    Science.gov (United States)

    Bauer, Thomas; Strauss, Peter; Stiper, Katrin; Klipa, Vladimir; Popescu, Daniela; Winter, Silvia; Zaller, Johann G.

    2016-04-01

    Successful viticulture is mainly influenced by soil and climate. The availability of water during the growing season highly influences wine quality and quantity. To protect soil from being eroded most of the winegrowers keep the inter row zones of the vineyards green. Greening also helps to provide water-stress to the grapes for harvesting high quality wines. However, these greening strategies concerning the intensity of inter row management differ from farm to farm and are mainly based on personal experience of the winegrowers. However to what extent different inter row management practices affect soil physical properties are not clearly understood yet. To measure possible effects of inter row management in vineyards on soil physical parameters we selected paired vineyards with different inter row management in Austria and Romania. In total more than 7000 soil analysis were conducted for saturated and unsaturated hydraulic conductivity, soil water retention, water stable aggregates, total organic carbon, cation exchange capacity, potassium, phosphorous, soil texture, bulk density and water infiltration. The comparison between high intensity management with at least one soil disturbance per year, medium intensity with one soil disturbance every second inter row per year and low intensity management with no soil disturbance since at least 5 years indicates that investigated soil physical properties did not improve for the upper soil layer (3-8cm). This is in contrast to general perceptions of improved soil physical properties due to low intensity of inter row management, i.e. permanent vegetated inter rows. This may be attributed to long term and high frequency mechanical stress by agricultural machinery in inter rows.

  5. Multidetector-row computed tomography management of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Yasui, Takahiro; Tanabe, Nobuhiro; Terada, Jiro

    2007-01-01

    The purpose of this study was to evaluate the usefulness and safety of multidetector-row computed tomography (MDCT) pulmonary angiography and indirect venography management of acute pulmonary embolism (PE), including indication for inferior vena cava (IVC) filter. Seventy-one consecutive patients who were clinically suspected of PE and underwent 16-slice MDCT pulmonary angiography and indirect venography were enrolled. Management included indication of IVC filter for patients with extensive deep venous thrombosis (DVT) in submassive or massive PE. A right ventricular to left ventricular short-axis diameter by MDCT >1.0 was judged as submassive PE. All patients were followed for 1 year. MDCT identified 50 patients with venous thromboembolism and 47 patients had acute PE: 4 were judged as massive, 14 as submassive, and 29 as non-massive by MDCT; 3 patients had DVT alone and 7 patients had caval or iliac DVT. Only 1 patient with massive PE and DVT near the right atrium died of recurrence. No other patients died of PE. Management based on MDCT pulmonary angiography combined with indirect venography is considered to be safe and reliable in patients with suspected acute PE. (author)

  6. Breast multidetector-row CT with histopathologic correlation

    International Nuclear Information System (INIS)

    Takeuchi, Makiko; Yamashita, Akiyoshi; Ohgi, Kazuyuki; Kobori, Kenichi; Furukawa, Takashi

    2004-01-01

    The purpose of this study was to evaluate the correlation between multidetector-row CT (MDCT) and histopathologic findings using the same MDCT image as the histopathologic cross-section. MDCT with contrast enhancement was performed in 10 patients with breast cancers (8 invasive ductal carcinomas, one invasive lobular carcinoma, and one non-invasive ductal carcinoma). We tried to reconstruct multiplanar reconstructions (MPR) in the same plane as the histopathologic cross-section, and we evaluated the histopathologic findings of the false-positive lesions. In all cases, we obtained the same MDCT image as the histopathologic cross-section. There were 10 main lesions and 18 other lesions. In the other lesions, we found no false-negative lesions and 11 false-positive lesions. False-positive lesions included periductal fibrosis, cystic change, duct papillomatosis, sclerosing adenosis, fibroadenoma, and others. Using MDCT of the breast, it is possible to obtain good correlation between CT images and histopathologic findings. MDCT is thought to be useful in the evaluation CT findings on the basis of histopathologic evidence. (author)

  7. Numerical investigation of flow past a row of rectangular rods

    Directory of Open Access Journals (Sweden)

    S.Ul. Islam

    2016-09-01

    Full Text Available A numerical study of uniform flow past a row of rectangular rods with aspect ratio defined as R = width/height = 0.5 is performed using the Lattice Boltzmann method. For this study the Reynolds number (Re is fixed at 150, while spacings between the rods (g are taken in the range from 1 to 6. Depending on g, the flow is classified into four patterns: flip-flopping, nearly unsteady-inphase, modulated inphase-antiphase non-synchronized and synchronized. Sudden jumps in physical parameters were observed, attaining either maximum or minimum values, with the change in flow patterns. The mean drag coefficient (Cdmean of middle rod is higher than the second and fourth rod for flip-flopping pattern while in case of nearly unsteady-inphase the middle rod attains minimum drag coefficient. It is also found that the Strouhal number (St of first, second and fifth rod decreases as g increases while that of other two have mixed trend. The results further show that there exist secondary interaction frequencies together with primary vortex shedding frequency due to jet in the gap between rods for 1 ⩽ g ⩽ 3. For the average values of Cdmean and St, an empirical relation is also given as a function of gap spacing. This relation shows that the average values of Cdmean and St approach to those of single rectangular rod with increment in g.

  8. Stress analysis of steam generator row-1 tubes

    International Nuclear Information System (INIS)

    Kim, Woo Gon; Ryu, Woo Seog; Lee, Ho Jin; Kim, Sung Chung

    2000-01-01

    Residual stresses induced in U-bending and tube-to-tubesheet joining processes of PWR's steam generator row-1 tube were measured by X-ray method and Hole-Drilling Method(HDM). The stresses resulting from the internal pressure and the temperature gradient in the steam generator were also estimated theoretically. In U-bent regions, the residual stresses at extrados were induced with compressive stress(-), and its maximum value reached -319 Mpa in axial direction at ψ=0 .deg. in position. Maximum tensile residual stress of 170 MPa was found to be at the flank side at position of ψ=90 deg., i.e., at apex region. In tube-to-tubesheet joining methods, the residual stresses induced by the explosive joint method were found to be lower than that by the mechanical roll method. The gradient of residual stress along the expanded tube was highest at the transition region, and the residual stress in circumferential direction was found to be higher than the residual stress in axial direction. Hoop stress due to an internal pressure between primary and secondary side was analyzed to be 76 MPa and thermal stress was 45 MPa

  9. Universal gate-set for trapped-ion qubits using a narrow linewidth diode laser

    International Nuclear Information System (INIS)

    Akerman, Nitzan; Navon, Nir; Kotler, Shlomi; Glickman, Yinnon; Ozeri, Roee

    2015-01-01

    We report on the implementation of a high fidelity universal gate-set on optical qubits based on trapped 88 Sr + ions for the purpose of quantum information processing. All coherent operations were performed using a narrow linewidth diode laser. We employed a master-slave configuration for the laser, where an ultra low expansion glass Fabry–Perot cavity is used as a stable reference as well as a spectral filter. We characterized the laser spectrum using the ions with a modified Ramsey sequence which eliminated the affect of the magnetic field noise. We demonstrated high fidelity single qubit gates with individual addressing, based on inhomogeneous micromotion, on a two-ion chain as well as the Mølmer–Sørensen two-qubit entangling gate. (paper)

  10. New EB curing system for narrow web, using Min-EB

    International Nuclear Information System (INIS)

    Nakamura, Tetsuhisa; Tominaga, Hiroshi; Oizumi, Kei

    2003-01-01

    We, TOYO INK, developed the new equipment of EB curing system for narrow web composed of vacuum tube-type electron beam irradiation apparatus called Min-EB which is specialized with ultra-low voltage, 50-60 KV, and not damaging against the substrate. The new development is very small size, 66 cm width, 64 cm depth, 80 cm height and convenient to install into printing and coating machines. Several tubes, Min-EB, are assembled to be multi-tube module, called MTM, to easily handle. Basically we can change the irradiation width and printing and coating speed by increasing MTM due to the sheet size and printing and coating condition. We got good results, showing high density for the printed film, after used new EB curing system. (author)

  11. Threshold Multi Split-Row algorithm for decoding irregular LDPC codes

    Directory of Open Access Journals (Sweden)

    Chakir Aqil

    2017-12-01

    Full Text Available In this work, we propose a new threshold multi split-row algorithm in order to improve the multi split-row algorithm for LDPC irregular codes decoding. We give a complete description of our algorithm as well as its advantages for the LDPC codes. The simulation results over an additive white gaussian channel show that an improvement in code error performance between 0.4 dB and 0.6 dB compared to the multi split-row algorithm.

  12. Resonant Quasi-Optical Systems with Multi-Row Periodic Structures

    DEFF Research Database (Denmark)

    Oleksandr, Rybalko; Rybalko, Yu A.; Buriak, I. A.

    2017-01-01

    Selective properties of resonant quasi-optical systems with periodical multi-row structures in millimeter wavelength range are described. The possibility of selection fluctuations in the volume of open resonator using double-row periodic elements was shown in the experiment at 70-80 GHz. Advantages...... and possibility of control the energy characteristics of such structures are also described. The obtained experimental data is used to confirm the results of computational analysis previously described in the literature. Implementation of resonant quasi-optical systems with multi-row periodic structures...

  13. Rowing, the ultimate challenge to the human body - implications for physiological variables

    DEFF Research Database (Denmark)

    Volianitis, S.; Secher, Niels H.

    2009-01-01

    Clinical diagnoses depend on a variety of physiological variables but the full range of these variables is seldom known. With the load placed on the human body during competitive rowing, the physiological range for several variables is illustrated. The extreme work produced during rowing...... is explained by the seated position and the associated ability to increase venous return and, thus, cardiac output. This review highlights experimental work on Olympic rowing that presents a unique challenge to the human capacities, including cerebral metabolism, to unprecedented limits, and provides a unique...

  14. Biomechanical comparison of 4 double-row suture-bridging rotator cuff repair techniques using different medial-row configurations.

    Science.gov (United States)

    Pauly, Stephan; Kieser, Bettina; Schill, Alexander; Gerhardt, Christian; Scheibel, Markus

    2010-10-01

    Biomechanical comparison of different suture-bridge configurations of the medial row with respect to initial construct stability (time 0, porcine model). In 40 porcine fresh-frozen shoulders, the infraspinatus tendons were dissected from their insertions. All specimens were operated on by use of the suture-bridge technique, only differing in terms of the medial-row suture-grasping configuration, and randomized into 4 groups: (1) single-mattress (SM) technique, (2) double-mattress (DM) technique, (3) cross-stitch (CS) technique, and (4) double-pulley (DP) technique. Identical suture anchors were used for all specimens (medial: Bio-Corkscrew FT 5.5 [Arthrex, Naples, FL]; lateral: Bio-PushLock 3.5 [Arthrex]). All repairs were cyclically loaded from 10 to 60 N until 10 to 200 N (20-N stepwise increase after 50 cycles each) with a material testing machine. Forces at 3 and 5 mm of gap formation, mode of failure, and maximum load to failure were recorded. The DM technique had the highest ultimate tensile strength (368.6 ± 99.5 N) compared with the DP (248.4 ± 122.7 N), SM (204.3 ± 90 N), and CS (184.9 ± 63.8 N) techniques (P = .004). The DM technique provided maximal force resistance until 3 and 5 mm of gap formation (90.0 ± 18.1 N and 128.0 ± 32.3 N, respectively) compared with the CS (72 ± 8.9 N and 108 ± 20.2 N, respectively), SM (66.0 ± 8.9 N and 90.0 ± 26.9 N, respectively), and DP (62.2 ± 6.2 N and 71 ± 13.2 N, respectively) techniques (P biomechanical construct stability at time 0 in this porcine ex vivo model. This technique increases initial stability and resistance to suture cutting through the rotator cuff tendon after arthroscopic suture-bridge repair. Copyright © 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. Single-row vs. double-row arthroscopic rotator cuff repair: clinical and 3 Tesla MR arthrography results

    Science.gov (United States)

    2013-01-01

    Background Arthroscopic rotator cuff repair has become popular in the last few years because it avoids large skin incisions and deltoid detachment and dysfunction. Earlier arthroscopic single-row (SR) repair methods achieved only partial restoration of the original footprint of the tendons of the rotator cuff, while double-row (DR) repair methods presented many biomechanical advantages and higher rates of tendon-to-bone healing. However, DR repair failed to demonstrate better clinical results than SR repair in clinical trials. MR imaging at 3 Tesla, especially with intra-articular contrast medium (MRA), showed a better diagnostic performance than 1.5 Tesla in the musculoskeletal setting. The objective of this study was to retrospectively evaluate the clinical and 3 Tesla MRA results in two groups of patients operated on for a medium-sized full-thickness rotator cuff tear with two different techniques. Methods The first group consisted of 20 patients operated on with the SR technique; the second group consisted of 20 patients operated on with the DR technique. All patients were evaluated at a minimum of 3 years after surgery. The primary end point was the re-tear rate at 3 Tesla MRA. The secondary end points were the Constant-Murley Scale (CMS), the Simple Shoulder Test (SST) scores, surgical time and implant expense. Results The mean follow-up was 40 months in the SR group and 38.9 months in the DR group. The mean postoperative CMS was 70 in the SR group and 68 in the DR group. The mean SST score was 9.4 in the SR group and 10.1 in the DR group. The re-tear rate was 60% in the SR group and 25% in the DR group. Leakage of the contrast medium was observed in all patients. Conclusions To the best of our knowledge, this is the first report on 3 Tesla MRA in the evaluation of two different techniques of rotator cuff repair. DR repair resulted in a statistically significant lower re-tear rate, with longer surgical time and higher implant expense, despite no

  16. Single-row vs. double-row arthroscopic rotator cuff repair: clinical and 3 Tesla MR arthrography results

    Directory of Open Access Journals (Sweden)

    Tudisco Cosimo

    2013-01-01

    Full Text Available Abstract Background Arthroscopic rotator cuff repair has become popular in the last few years because it avoids large skin incisions and deltoid detachment and dysfunction. Earlier arthroscopic single-row (SR repair methods achieved only partial restoration of the original footprint of the tendons of the rotator cuff, while double-row (DR repair methods presented many biomechanical advantages and higher rates of tendon-to-bone healing. However, DR repair failed to demonstrate better clinical results than SR repair in clinical trials. MR imaging at 3 Tesla, especially with intra-articular contrast medium (MRA, showed a better diagnostic performance than 1.5 Tesla in the musculoskeletal setting. The objective of this study was to retrospectively evaluate the clinical and 3 Tesla MRA results in two groups of patients operated on for a medium-sized full-thickness rotator cuff tear with two different techniques. Methods The first group consisted of 20 patients operated on with the SR technique; the second group consisted of 20 patients operated on with the DR technique. All patients were evaluated at a minimum of 3 years after surgery. The primary end point was the re-tear rate at 3 Tesla MRA. The secondary end points were the Constant-Murley Scale (CMS, the Simple Shoulder Test (SST scores, surgical time and implant expense. Results The mean follow-up was 40 months in the SR group and 38.9 months in the DR group. The mean postoperative CMS was 70 in the SR group and 68 in the DR group. The mean SST score was 9.4 in the SR group and 10.1 in the DR group. The re-tear rate was 60% in the SR group and 25% in the DR group. Leakage of the contrast medium was observed in all patients. Conclusions To the best of our knowledge, this is the first report on 3 Tesla MRA in the evaluation of two different techniques of rotator cuff repair. DR repair resulted in a statistically significant lower re-tear rate, with longer surgical time and higher implant

  17. Single-row vs. double-row arthroscopic rotator cuff repair: clinical and 3 Tesla MR arthrography results.

    Science.gov (United States)

    Tudisco, Cosimo; Bisicchia, Salvatore; Savarese, Eugenio; Fiori, Roberto; Bartolucci, Dario A; Masala, Salvatore; Simonetti, Giovanni

    2013-01-27

    Arthroscopic rotator cuff repair has become popular in the last few years because it avoids large skin incisions and deltoid detachment and dysfunction. Earlier arthroscopic single-row (SR) repair methods achieved only partial restoration of the original footprint of the tendons of the rotator cuff, while double-row (DR) repair methods presented many biomechanical advantages and higher rates of tendon-to-bone healing. However, DR repair failed to demonstrate better clinical results than SR repair in clinical trials. MR imaging at 3 Tesla, especially with intra-articular contrast medium (MRA), showed a better diagnostic performance than 1.5 Tesla in the musculoskeletal setting. The objective of this study was to retrospectively evaluate the clinical and 3 Tesla MRA results in two groups of patients operated on for a medium-sized full-thickness rotator cuff tear with two different techniques. The first group consisted of 20 patients operated on with the SR technique; the second group consisted of 20 patients operated on with the DR technique. All patients were evaluated at a minimum of 3 years after surgery. The primary end point was the re-tear rate at 3 Tesla MRA. The secondary end points were the Constant-Murley Scale (CMS), the Simple Shoulder Test (SST) scores, surgical time and implant expense. The mean follow-up was 40 months in the SR group and 38.9 months in the DR group. The mean postoperative CMS was 70 in the SR group and 68 in the DR group. The mean SST score was 9.4 in the SR group and 10.1 in the DR group. The re-tear rate was 60% in the SR group and 25% in the DR group. Leakage of the contrast medium was observed in all patients. To the best of our knowledge, this is the first report on 3 Tesla MRA in the evaluation of two different techniques of rotator cuff repair. DR repair resulted in a statistically significant lower re-tear rate, with longer surgical time and higher implant expense, despite no difference in clinical outcomes. We think that

  18. Properties of Narrow line Seyfert 1 galaxies

    Science.gov (United States)

    Rakshit, Suvendu; Stalin, Chelliah Subramonian; Chand, Hum; Zhang, Xue-Guang

    2018-04-01

    Narrow line Seyfert 1 (NLSy1) galaxies constitute a class of active galactic nuclei characterized by the full width at half maximum (FWHM) of the Hα broad emission line 10 pixel-1. A strong correlation between the Hα and Hα emission lines is found both in the FWHM and flux. The nuclear continuum luminosity is found to be strongly correlated with the luminosity of Hα, Hα and [O III] emission lines. The black hole mass in NLSy1 galaxies is lower compared to their broad line counterparts. Compared to BLSy1 galaxies, NLSy1 galaxies have a stronger FeII emission and a higher Eddington ratio that place them in the extreme upper right corner of the R4570 - λEdd diagram. The distribution of the radio-loudness parameter (R) in NLSy1 galaxies drops rapidly at R>10 compared to the BLSy1 galaxies that have powerful radio jets. The soft X-ray photon index in NLSy1 galaxies is on average higher (2.9 ± 0.9) than BLSy1 galaxies (2.4 ± 0.8). It is anti-correlated with the Hα width but correlated with the FeII strength. NLSy1 galaxies on average have a lower amplitude of optical variability compared to their broad lines counterparts. These results suggest Eddington ratio as the main parameter that drives optical variability in these sources.

  19. Thermoelectricity in correlated narrow-gap semiconductors

    Science.gov (United States)

    Tomczak, Jan M.

    2018-05-01

    We review many-body effects, their microscopic origin, as well as their impact on thermoelectricity in correlated narrow-gap semiconductors. Members of this class—such as FeSi and FeSb2—display an unusual temperature dependence in various observables: insulating with large thermopowers at low temperatures, they turn bad metals at temperatures much smaller than the size of their gaps. This insulator-to-metal crossover is accompanied by spectral weight-transfers over large energies in the optical conductivity and by a gradual transition from activated to Curie–Weiss-like behaviour in the magnetic susceptibility. We show a retrospective of the understanding of these phenomena, discuss the relation to heavy-fermion Kondo insulators—such as Ce3Bi4Pt3 for which we present new results—and propose a general classification of paramagnetic insulators. From the latter, FeSi emerges as an orbital-selective Kondo insulator. Focussing on intermetallics such as silicides, antimonides, skutterudites, and Heusler compounds we showcase successes and challenges for the realistic simulation of transport properties in the presence of electronic correlations. Further, we explore new avenues in which electronic correlations may contribute to the improvement of thermoelectric performance.

  20. Thermal tuning On narrow linewidth fiber laser

    Science.gov (United States)

    Han, Peiqi; Liu, Tianshan; Gao, Xincun; Ren, Shiwei

    2010-10-01

    At present, people have been dedicated to high-speed and large-capacity optical fiber communication system. Studies have been shown that optical wavelength division multiplexing (WDM) technology is an effective means of communication to increase the channel capacity. Tunable lasers have very important applications in high-speed, largecapacity optical communications, and distributed sensing, it can provide narrow linewidth and tunable laser for highspeed optical communication. As the erbium-doped fiber amplifier has a large gain bandwidth, the erbium-doped fiber laser can be achieved lasing wavelength tunable by adding a tunable filter components, so tunable filter device is the key components in tunable fiber laser.At present, fiber laser wavelength is tuned by PZT, if thermal wavelength tuning is combined with PZT, a broader range of wavelength tuning is appearance . Erbium-doped fiber laser is used in the experiments,the main research is the physical characteristics of fiber grating temperature-dependent relationship and the fiber grating laser wavelength effects. It is found that the fiber laser wavelength changes continuously with temperature, tracking several temperature points observed the self-heterodyne spectrum and found that the changes in spectra of the 3dB bandwidth of less than 1kHz, and therefore the fiber laser with election-mode fiber Bragg grating shows excellent spectral properties and wavelength stability.

  1. Ultra Low Concentration Adsorption Equilibria

    National Research Council Canada - National Science Library

    Mahle, John J; Buettner, Leonard C; LeVan, M. D; Schindler, Bryan J

    2006-01-01

    .... Specifically this work focuses on novel experimental and modeling methods to characterize and predict at ultra-low chemical vapor concentrations the protection afforded by adsorption-based vapor filtration systems...

  2. Anatomia e ultra-estrutura foliar de Cyperus maritimus Poir. (Cyperaceae: estratégias adaptativas ao ambiente de dunas litorâneas Leaf anatomy and ultrastructure of Cyperus maritimus Poir. (Cyperaceae: adaptive strategies for coastal dune environment

    Directory of Open Access Journals (Sweden)

    Shirley Martins

    2008-06-01

    with thickened outer periclinal walls. The stomata are paracitic and the pore sometimes obstructed by wax. Under the adaxial epidermis, there are several layers of aqueous parenchyma. The vascular bundles occur in multiple rows, the peripheral row having bundles with narrower diameters than the central row. Characters related to Kranz syndrome of the chlorocyperoid type were observed. Ultrastructural features support a possible C4 pathway in this species. This work is the first citation of chloroplasts in the cells of the vascular system for the genus. In this study, it was possible to observe several important features of plants submitted to water and salt stress, such as: wax, thickened outer periclinal walls of the epidermal cells, aqueous parenchyma and Kranz syndrome.

  3. Functional and structural comparisons of the arthroscopic knotless double-row suture bridge and single-row repair for anterosuperior rotator cuff tears.

    Science.gov (United States)

    Ide, Junji; Karasugi, Tatsuki; Okamoto, Nobukazu; Taniwaki, Takuya; Oka, Kiyoshi; Mizuta, Hiroshi

    2015-10-01

    We compared the outcomes of knotless double-row suture bridge and single-row repairs in patients undergoing arthroscopic repair for anterosuperior rotator cuff tears. We included 61 full-thickness anterosuperior rotator cuff tears treated by arthroscopic repair, namely, single-row repair (group 1: 25 shoulders; mean patient age, 64 years) and the knotless double-row suture bridge repair (group 2: 36 shoulders; mean patient age, 62 years). Preoperative and postoperative magnetic resonance imaging was performed for all shoulders. Clinical outcomes were evaluated for mean follow-up periods of 81 months (range, 72-96 months) in group 1 and 34 months (range, 24-42 months) in group 2, using the University of California, Los Angeles and Japanese Orthopaedic Association assessments. At the final follow-up, both groups showed improvement in the average University of California, Los Angeles and Japanese Orthopaedic Association scores and range of motion, although no intergroup differences were observed. Both groups showed improved abduction strength, and the average score was higher in group 2 (P = .0112). The lift-off and belly-press test results were improved in both groups. Postoperatively, the incidence of positive lift-off tests tended to be lower (P = .075) and that of positive belly-press tests was lower in group 2, P = .049). The repair failure rate tended to be lower in group 2 (14% [5 of 36]) than in group 1 (32% [8 of 25]; P = .0839). Arthroscopic knotless double-row suture bridge repair of anterosuperior rotator cuff tears yielded functional outcomes equivalent to those of single-row repair and may be useful for improving subscapularis function, abduction strength, and tendon healing. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Researchers develop CCD image sensor with 20ns per row parallel readout time

    CERN Multimedia

    Bush, S

    2004-01-01

    "Scientists at the Rutherford Appleton Laboratory (RAL) in Oxfordshire have developed what they claim is the fastest CCD (charge-coupled device) image sensor, with a readout time which is 20ns per row" (1/2 page)

  5. Passive microwave remote sensing of soil moisture - The effect of tilled row structure

    Science.gov (United States)

    Wang, J. R.; Newton, R. W.; Rouse, J. W., Jr.

    1980-01-01

    The tilled row structure in agricultural fields is one of the important factors affecting observations of microwave emission from such fields. Measurements of this effect were performed with L-band and X-band radiometers mounted on a mobile truck on a bare 40 m x 45 m row tilled field; the soil moisture content during measurements ranged from 10 to 30% by dry weight. Results showed that the variations of the antenna temperatures with incident angle changed with the azimuth angle measured from the row direction. It is found that the observed difference between horizontally and vertically polarized antenna temperatures is due to the change in the local angle of field emission within the antenna field of view caused by the large-scale row structure.

  6. Effect of seed rate and row spacing in seed production of Festulolium

    DEFF Research Database (Denmark)

    Deleuran, L C; Gislum, R; Boelt, B

    2010-01-01

    -type festulolium, Paulita, and in a fescue-type festulolium, Hykor. The objectives were to examine the influence of row spacing (12, 24, and 36 cm) and seed rate (8, 12, or 16 kg ha-1) on plant establishment, development, and seed yield. Observations of autumn and spring in-row plant densities indicated......Festulolium ( Festulolium) is a cross between the two species fescue (Festuca L.) and ryegrass (Lolium L.) and is a promising forage and seed crop. To stimulate the production of Danish organic festulolium seeds a three-year field experiment was performed from 1999 to 2002 in a ryegrass...... satisfactory plant establishment in all combinations of seed rate and row spacing. The number of reproductive tillers was in the range from 800 to 2200 m-2 in Paulita and from 500 to 1300 m-2 in Hykor. Row spacing had an effect on the number of reproductive tillers and in both cultivars the highest number...

  7. Effect of Plant and Row Spacing on the Yield and Oil Contents of ...

    African Journals Online (AJOL)

    Key words: Castor, Plant spacing, row spacing, seed yield. Introduction ... optimum plant population, fertilizer, quality seed, weeding practices, optimum plant ... 30 000 plants/ha for crops grown in the 750 to 900 mm rain fall is optimum. He.

  8. Skid row alcoholism--an objective definition for use in detoxification and treatment planning.

    Science.gov (United States)

    Halikas, J A; Lyttle, M D; Morse, C L

    1984-05-01

    Objective criteria were used to separate skid row alcoholics from others in a public detoxification program. The two groups thus formed were found to have different characteristics, which could lead to more individualized and effective treatment planning in such settings.

  9. Lung surgery assisted by multidetector-row computed tomographic simulation

    International Nuclear Information System (INIS)

    Oizumi, Hiroyuki; Endoh, Makoto; Ota, Hiroshi; Takeda, Shinichi; Suzuki, Jun; Fukaya, Ken; Chiba, Masato; Sadahiro, Mitsuaki

    2009-01-01

    We describe the benefits of lung resection simulation using multidetector computed tomography (MDCT). Since 2004, the 1.0-mm slice digital imaging and communications in medicine (DICOM) server has been used for storing data obtained using 64-row MDCT. We observed that an abnormality could not be visualized from the pleural surface in 10 nodules of 18 lesions undergoing wedge lung resection. These 10 nodules were resected through simulation using a three-dimensional (3D) volume-rendering method by considering parameters such as the position, depth, or distance from the interlobar abnormalities, etc., without the need for any marking methods. For lung lobectomy, identification of the branching structures, diameter, and length of the arteries is useful in selecting the procedure for blood vessel treatment. However, in the initial 10 patients of this series, the preoperative identification of 2 small arterial branches was unsuccessful when this method was used. Therefore, it is important to carefully examine the original data in all 3 views, id est (i.e.), axial, sagittal, and coronal views. The visualization of venous branches in affected segments and intersegmental veins has facilitated the preoperative determination of the anatomical intersegmental plane. We divided the cases of thoracoscopic lung segmentectomy into 3 groups (level 1: simple, level 2: intermediate, and level 3: complex) on the basis of the technical complexity. Only level 1 segmentectomies were performed without MDCT simulation. Further, level 2 and 3 segmentectomies could be successfully performed because of the introduction of MDCT simulation in 25 of 35 patients. Thus, this simulation technique may be useful during a thoracoscopic procedure for lung surgery. (author)

  10. Structure of the cobalt-filled missing-row reconstruction of Pt(110)

    International Nuclear Information System (INIS)

    Klein, C.; Koller, R.; Schmid, M.; Varga, P.; Lundgren, E.; Maca, F.; Redinger, J.

    2004-01-01

    The atomic structure of 0.5 monolayer (ML) Co deposited on Pt(110) was investigated by quantitative low-energy electron diffraction and ab initio density functional theory calculations, showing a pronounced inward relaxation and a filling of the missing-row sites of the Pt(110) substrate by Co atoms. Up to this Co coverage no significant intermixing of Pt atoms with Co atoms was observed by scanning tunneling microscopy, resulting in an alternating arrangement of pure Co and Pt rows

  11. Fungal Distribution and Varieties Resistance to Kernel Discoloration in Korean Two-rowed Barley

    OpenAIRE

    Sang-Hyun Shin; Eun-Jo Seo; Jae-Seong Choi; JungKwan Lee; Jong-Chul Park; Chun-Sik Kang

    2013-01-01

    Barley kernel discoloration (KD) leads to substantial loss in value through downgrading and discounting of malting barley. The objective of this research is to investigate fungal distribution and varieties resistance to KD in Korean two-rowed barley. Several fungal organisms including Alternaria spp., Fusarium spp., Aspergillus spp., Epicoccum spp. and Rhizopus spp. were isolated from Korean two-rowed barley representing KD. The symptoms of KD were brown and black discolorations o...

  12. Biomechanical Comparison of Single- Versus Double-Row Capsulolabral Repair for Shoulder Instability: A Review

    OpenAIRE

    Yousif, Matthew John; Bicos, James

    2017-01-01

    Background: The glenohumeral joint is the most commonly dislocated joint in the body. Failure rates of capsulolabral repair have been reported to be approximately 8%. Recent focus has been on restoration of the capsulolabral complex by a double-row capsulolabral repair technique in an effort to decrease redislocation rates after arthroscopic capsulolabral repair. Purpose: To present a review of the biomechanical literature comparing single- versus double-row capsulolabral repairs and discuss ...

  13. Clinical outcomes of arthroscopic single and double row repair in full thickness rotator cuff tears.

    Science.gov (United States)

    Ji, Jong-Hun; Shafi, Mohamed; Kim, Weon-Yoo; Kim, Young-Yul

    2010-07-01

    There has been a recent interest in the double row repair method for arthroscopic rotator cuff repair following favourable biomechanical results reported by some studies. The purpose of this study was to compare the clinical results of arthroscopic single row and double row repair methods in the full-thickness rotator cuff tears. 22 patients of arthroscopic single row repair (group I) and 25 patients who underwent double row repair (group II) from March 2003 to March 2005 were retrospectively evaluated and compared for the clinical outcomes. The mean age was 58 years and 56 years respectively for group I and II. The average follow-up in the two groups was 24 months. The evaluation was done by using the University of California Los Angeles (UCLA) rating scale and the shoulder index of the American Shoulder and Elbow Surgeons (ASES). In Group I, the mean ASES score increased from 30.48 to 87.40 and the mean ASES score increased from 32.00 to 91.45 in the Group II. The mean UCLA score increased from the preoperative 12.23 to 30.82 in Group I and from 12.20 to 32.40 in Group II. Each method has shown no statistical clinical differences between two methods, but based on the sub scores of UCLA score, the double row repair method yields better results for the strength, and it gives more satisfaction to the patients than the single row repair method. Comparing the two methods, double row repair group showed better clinical results in recovering strength and gave more satisfaction to the patients but no statistical clinical difference was found between 2 methods.

  14. Row spacing effects on light extinction coefficients of corn, sorghum, soybean, and sunflower

    International Nuclear Information System (INIS)

    Flénet, F.; Kiniry, J.R.; Board, J.E.; Westgate, M.E.; Reicosky, D.C.

    1996-01-01

    In many crop models, light intercepted by a canopy (IPAR) is calculated from a Beer's Law equation: IPAR = PAR x [1- exp(-k x LAI)], where k is the extinction coefficient, PAR the photosynthetically active radiation, and LAI the leaf area index. The first objective of this study was to investigate the effect of row spacing on k for corn (Zea mays L.), sorghum [Sorghum bicolor (L.) Moench], soybean [Glycine max (L.) Merr.], and sunflower (Helianthus annuus L.) to provide information for modeling. Data from literature and from an experiment conducted at Temple, TX, were evaluated. The second objective was to investigate effects of time of day and stage of crop development on k for different row spacings. Seeds of all four species were sown in rows 0.35, 0.66, or 1.00 m apart. Measurements of canopy light interception were taken near solar noon on two dates before anthesis. At anthesis, extinction coefficients were determined at 0845, 1015, and 1145 h (solar time). The extinction coefficient showed a linear decrease as row spacing increased. For each crop, the effect of row spacing on k was described by one linear regression for most data. Stage of crop development and stage of development x row spacing interaction did not significantly affect k during the period of measurements. The effect of time of day was significant for all four crops, and the time of day x row spacing interaction was significant for soybean and sunflower. Thus, modeling light interception for different row spacings should account for these effects

  15. Clinical outcomes of arthroscopic single and double row repair in full thickness rotator cuff tears

    Directory of Open Access Journals (Sweden)

    Ji Jong-Hun

    2010-01-01

    Full Text Available Background: There has been a recent interest in the double row repair method for arthroscopic rotator cuff repair following favourable biomechanical results reported by some studies. The purpose of this study was to compare the clinical results of arthroscopic single row and double row repair methods in the full-thickness rotator cuff tears. Materials and Methods: 22 patients of arthroscopic single row repair (group I and 25 patients who underwent double row repair (group II from March 2003 to March 2005 were retrospectively evaluated and compared for the clinical outcomes. The mean age was 58 years and 56 years respectively for group I and II. The average follow-up in the two groups was 24 months. The evaluation was done by using the University of California Los Angeles (UCLA rating scale and the shoulder index of the American Shoulder and Elbow Surgeons (ASES. Results: In Group I, the mean ASES score increased from 30.48 to 87.40 and the mean ASES score increased from 32.00 to 91.45 in the Group II. The mean UCLA score increased from the preoperative 12.23 to 30.82 in Group I and from 12.20 to 32.40 in Group II. Each method has shown no statistical clinical differences between two methods, but based on the sub scores of UCLA score, the double row repair method yields better results for the strength, and it gives more satisfaction to the patients than the single row repair method. Conclusions: Comparing the two methods, double row repair group showed better clinical results in recovering strength and gave more satisfaction to the patients but no statistical clinical difference was found between 2 methods.

  16. Narrow Networks on the Individual Marketplace in 2017.

    Science.gov (United States)

    Polski, Daniel; Weiner, Janet; Zhang, Yuehan

    2017-09-01

    This Issue Brief describes the breadth of physician networks on the ACA marketplaces in 2017. We find that the overall rate of narrow networks is 21%, which is a decline since 2014 (31%) and 2016 (25%). Narrow networks are concentrated in plans sold on state-based marketplaces, at 42%, compared to 10% of plans on federally-facilitated marketplaces. Issuers that have traditionally offered Medicaid coverage have the highest prevalence of narrow network plans at 36%, with regional/local plans and provider-based plans close behind at 27% and 30%. We also find large differences in narrow networks by state and by plan type.

  17. Ultra wideband wireless body area networks

    CERN Document Server

    Thotahewa, Kasun Maduranga Silva; Yuce, Mehmet Rasit

    2014-01-01

    This book explores the design of ultra wideband (UWB) technology for wireless body-area networks (WBAN).  The authors describe a novel implementation of WBAN sensor nodes that use UWB for data transmission and narrow band for data reception, enabling low power sensor nodes, with high data rate capability.  The discussion also includes power efficient, medium access control (MAC) protocol design for UWB based WBAN applications and the authors present a MAC protocol in which a guaranteed delivery mechanism is utilized to transfer data with high priority.  Readers will also benefit from this book’s feasibility analysis of the UWB technology for human implant applications through the study of electromagnetic and thermal power absorption of human tissue that is exposed to UWB signals.   • Describes hardware platform development for IR-UWB based WBAN communication; • Discusses power efficient medium access control (MAC) protocol design for IR-UWB based WBAN applications; • Includes feasibility analy...

  18. Relationship between noise, dose, and pitch in cardiac multi-detector row CT.

    Science.gov (United States)

    Primak, Andrew N; McCollough, Cynthia H; Bruesewitz, Michael R; Zhang, Jie; Fletcher, Joel G

    2006-01-01

    In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends on pitch because the spiral interpolation algorithm makes use of redundant data from different detector rows to decrease noise for pitch values less than 1 (and increase noise for pitch values > 1). However, in cardiac spiral CT, redundant data cannot be used because such data averaging would degrade the temporal resolution. Therefore, the behavior of noise versus pitch returns to the single detector row paradigm, with noise being independent of pitch. Consequently, since faster rotation times require lower pitch values in cardiac multi-detector row CT, dose is increased without a commensurate decrease in noise. Thus, the use of faster rotation times will improve temporal resolution, not alter noise, and increase dose. For a particular application, the higher dose resulting from faster rotation speeds should be justified by the clinical benefits of the improved temporal resolution. RSNA, 2006

  19. Integration of row spacing, mulching and herbicides on weed management in tomato

    International Nuclear Information System (INIS)

    Bakht, T.; Khan, I.A.

    2014-01-01

    A field experiment was conducted at the Research Farm of The University of Agriculture, Peshawar during the year 2012 to determine the impact of row spacing and weed management strategies on tomato (Lycopersicon esculentum Mill.). The local variety 'Roma' was sown in a randomized complete block (RCB) design with split plot arrangements, having four replications. The main plots were row spacings while subplots of the experiment comprised of ten treatments including five mulches viz., white and black polyethylene, wheat straw, newspaper and saw dust, three herbicide treatments (fenoxaprop-p-ethyl, pendimethalin and s-metolachlor), hand weeding and a weedy check. The data were recorded on weed density m/sup -2/, fresh and dry weed biomass, number of branches plant-1, and fruit yield (kg ha/sup -1/). All these parameters were significantly affected by row spacing and weed management treatments. Increase in weed population was observed with increasing in row spacing. The competitiveness of tomato with weeds can be enhanced by using black plastic as mulch. In light of the results, the row spacing of 60 cm is the optimum one for tomato plants, as the fruit yields decreased at 40 cm and 80 cm row spacing. (author)

  20. Archaeogenetic evidence of ancient nubian barley evolution from six to two-row indicates local adaptation.

    Directory of Open Access Journals (Sweden)

    Sarah A Palmer

    Full Text Available BACKGROUND: Archaeobotanical samples of barley (Hordeum vulgare L. found at Qasr Ibrim display a two-row phenotype that is unique to the region of archaeological sites upriver of the first cataract of the Nile, characterised by the development of distinctive lateral bracts. The phenotype occurs throughout all strata at Qasr Ibrim, which range in age from 3000 to a few hundred years. METHODOLOGY AND FINDINGS: We extracted ancient DNA from barley samples from the entire range of occupancy of the site, and studied the Vrs1 gene responsible for row number in extant barley. Surprisingly, we found a discord between the genotype and phenotype in all samples; all the barley had a genotype consistent with the six-row condition. These results indicate a six-row ancestry for the Qasr Ibrim barley, followed by a reassertion of the two-row condition. Modelling demonstrates that this sequence of evolutionary events requires a strong selection pressure. CONCLUSIONS: The two-row phenotype at Qasr Ibrim is caused by a different mechanism to that in extant barley. The strength of selection required for this mechanism to prevail indicates that the barley became locally adapted in the region in response to a local selection pressure. The consistency of the genotype/phenotype discord over time supports a scenario of adoption of this barley type by successive cultures, rather than the importation of new barley varieties associated with individual cultures.

  1. Prediction of Rowing Ergometer Performance from Functional Anaerobic Power, Strength and Anthropometric Components

    Directory of Open Access Journals (Sweden)

    Akça Firat

    2014-07-01

    Full Text Available The aim of this research was to develop different regression models to predict 2000 m rowing ergometer performance with the use of anthropometric, anaerobic and strength variables and to determine how precisely the prediction models constituted by different variables predict performance, when conducted together in the same equation or individually. 38 male collegiate rowers (20.17 ± 1.22 years participated in this study. Anthropometric, strength, 2000 m maximal rowing ergometer and rowing anaerobic power tests were applied. Multiple linear regression procedures were employed in SPSS 16 to constitute five different regression formulas using a different group of variables. The reliability of the regression models was expressed by R2 and the standard error of estimate (SEE. Relationships of all parameters with performance were investigated through Pearson correlation coefficients. The prediction model using a combination of anaerobic, strength and anthropometric variables was found to be the most reliable equation to predict 2000 m rowing ergometer performance (R2 = 0.92, SEE= 3.11 s. Besides, the equation that used rowing anaerobic and strength test results also provided a reliable prediction (R2 = 0.85, SEE= 4.27 s. As a conclusion, it seems clear that physiological determinants which are affected by anaerobic energy pathways should also get involved in the processes and models used for performance prediction and talent identification in rowing.

  2. Double row spacing and drip irrigation as technical options in energy sorghum management

    Directory of Open Access Journals (Sweden)

    Neri Roncucci

    2014-02-01

    Full Text Available The effect of two row spacing configurations and four water supply levels was investigated on sweet and fibre sorghum in Central Italy for two consecutive years. Results highlighted the influence of both irrigation and row spatial configuration on crop productivity. Indeed, several studies have pointed out the positive response of sorghum to irrigation in Mediterranean climate, as in this environment water stress represents one of the main limiting factors on crop productivity. On the other hand, few attempts have been made to explore the role of row spacing on energy sorghum productivity. Results outlined an average increase in sorghum dry biomass yield ranging from +23% to +79% at variable rates of water supply as compared to rainfed control. The positive effect of irrigation was also observed on leaf area index and radiation use efficiency. Moreover, we observed a crop yield increase, from 9% to 20%, under double row spacing compared to the standard planting pattern (i.e. single row spacing. Finally, it was confirmed the efficient use of water by sorghum and the great ability of sorghum to increase its biomass yield in response to increasing volumes of water supplied. Therefore, this work suggests how row spacing configuration and drip irrigation could be feasible technical options to increase sorghum biomass yields in Mediterranean environments. These techniques should be experienced by farmers towards a sustainable intensification of current cropping systems.

  3. Comparison between various patch wise strategies for reconstruction of ultra-spectral cubes captured with a compressive sensing system

    Science.gov (United States)

    Oiknine, Yaniv; August, Isaac Y.; Revah, Liat; Stern, Adrian

    2016-05-01

    Recently we introduced a Compressive Sensing Miniature Ultra-Spectral Imaging (CS-MUSI) system. The system is based on a single Liquid Crystal (LC) cell and a parallel sensor array where the liquid crystal cell performs spectral encoding. Within the framework of compressive sensing, the CS-MUSI system is able to reconstruct ultra-spectral cubes captured with only an amount of ~10% samples compared to a conventional system. Despite the compression, the technique is extremely complex computationally, because reconstruction of ultra-spectral images requires processing huge data cubes of Gigavoxel size. Fortunately, the computational effort can be alleviated by using separable operation. An additional way to reduce the reconstruction effort is to perform the reconstructions on patches. In this work, we consider processing on various patch shapes. We present an experimental comparison between various patch shapes chosen to process the ultra-spectral data captured with CS-MUSI system. The patches may be one dimensional (1D) for which the reconstruction is carried out spatially pixel-wise, or two dimensional (2D) - working on spatial rows/columns of the ultra-spectral cube, as well as three dimensional (3D).

  4. Mg2BIV: Narrow Bandgap Thermoelectric Semiconductors

    Science.gov (United States)

    Kim, Il-Ho

    2018-05-01

    Thermoelectric materials can convert thermal energy directly into electric energy and vice versa. The electricity generation from waste heat via thermoelectric devices can be considered as a new energy source. For instance, automotive exhaust gas and all industrial processes generate an enormous amount of waste heat that can be converted to electricity by using thermoelectric devices. Magnesium compound Mg2BIV (BIV = Si, Ge or Sn) has a favorable combination of physical and chemical properties and can be a good base for the development of new efficient thermoelectrics. Because they possess similar properties to those of group BIV elemental semiconductors, they have been recognized as good candidates for thermoelectric applications. Mg2Si, Mg2Ge and Mg2Sn with an antifluorite structure are narrow bandgap semiconductors with indirect band gaps of 0.77 eV, 0.74 eV, and 0.35 eV, respectively. Mg2BIV has been recognized as a promising material for thermoelectric energy conversion at temperatures ranging from 500 K to 800 K. Compared to other thermoelectric materials operating in the similar temperature range, such as PbTe and filled skutterudites, the important aspects of Mg2BIV are non-toxic and earth-abundant elements. Based on classical thermoelectric theory, the material factor β ( m* / m e)3/2μκ L -1 can be utilized as the criterion for thermoelectric material selection, where m* is the density-of-states effective mass, me is the mass of an electron, μ is the carrier mobility, and κL is the lattice thermal conductivity. The β for magnesium silicides is 14, which is very high compared to 0.8 for iron silicides, 1.4 for manganese silicides, and 2.6 for silicon-germanium alloys. In this paper, basic phenomena of thermoelectricity and transport parameters for thermoelectric materials were briefly introduced, and thermoelectric properties of Mg2BIV synthesized by using a solid-state reaction were reviewed. In addition, various Mg2BIV compounds were discussed

  5. Biomechanical Comparison of Arthroscopic Single- and Double-Row Repair Techniques for Acute Bony Bankart Lesions.

    Science.gov (United States)

    Spiegl, Ulrich J; Smith, Sean D; Todd, Jocelyn N; Coatney, Garrett A; Wijdicks, Coen A; Millett, Peter J

    2014-08-01

    Single- and double-row arthroscopic reconstruction techniques for acute bony Bankart lesions have been described in the literature. The double-row fixation technique would provide superior reduction and stability of a simulated bony Bankart lesion at time zero in a cadaveric model compared with the single-row technique. Controlled laboratory study. Testing was performed on 14 matched pairs of glenoids with simulated bony Bankart fractures with a defect width of 25% of the glenoid diameter. Half of the fractures were repaired with a double-row technique, while the contralateral glenoids were repaired with a single-row technique. The quality of fracture reduction was measured with a coordinate measuring machine. To determine the biomechanical stability of the repairs, specimens were preconditioned with 10 sinusoidal cycles between 5 and 25 N at 0.1 Hz and then pulled to failure in the anteromedial direction at a rate of 5 mm/min. Loads at 1 mm and 2 mm of fracture displacement were determined. The double-row technique required significantly higher forces to achieve fracture displacements of 1 mm (mean, 60.6 N; range, 39.0-93.3 N; P = .001) and 2 mm (mean, 94.4 N; range, 43.4-151.2 N; P = .004) than the single-row technique (1 mm: mean, 30.2 N; range, 14.0-54.1 N and 2 mm: mean, 63.7 N; range, 26.6-118.8 N). Significantly reduced fracture displacement was seen after double-row repair for both the unloaded condition (mean, 1.1 mm; range, 0.3-2.4 mm; P = .005) and in response to a 10-N anterior force applied to the defect (mean, 1.6 mm; range, 0.5-2.7 mm; P = .001) compared with single-row repair (unloaded: mean, 2.1 mm; range, 1.3-3.4 mm and loaded: mean, 3.4 mm; range, 1.9-4.7 mm). The double-row fixation technique resulted in improved fracture reduction and superior stability at time zero in this cadaveric model. This information may influence the surgical technique used to treat large osseous Bankart fractures and the postoperative rehabilitation protocols

  6. Q2 anti Q2 states with relatively narrow widths

    International Nuclear Information System (INIS)

    Ono, Seiji.

    1978-09-01

    Using the mass formulas which correctly predict the mass of mesons and baryons the mass of diquark states is computed. From this mass spectrum the existance of the observed narrow baryonia and wide baryonia can be naturally understood. Other relatively narrow Q 2 anti Q 2 states are predicted to exist. (orig.) [de

  7. Bayesian Face Recognition and Perceptual Narrowing in Face-Space

    Science.gov (United States)

    Balas, Benjamin

    2012-01-01

    During the first year of life, infants' face recognition abilities are subject to "perceptual narrowing", the end result of which is that observers lose the ability to distinguish previously discriminable faces (e.g. other-race faces) from one another. Perceptual narrowing has been reported for faces of different species and different races, in…

  8. Investigating the Effects of Typical Rowing Strength Training Practices on Strength and Power Development and 2,000 m Rowing Performance

    Directory of Open Access Journals (Sweden)

    Ian Gee Thomas

    2016-04-01

    Full Text Available This study aimed to determine the effects of a short-term, strength training intervention, typically undertaken by club-standard rowers, on 2,000 m rowing performance and strength and power development. Twenty-eight male rowers were randomly assigned to intervention or control groups. All participants performed baseline testing involving assessments of muscle soreness, creatine kinase activity (CK, maximal voluntary contraction (leg-extensors (MVC, static-squat jumps (SSJ, counter-movement jumps (CMJ, maximal rowing power strokes (PS and a 2,000 m rowing ergometer time-trial (2,000 m with accompanying respiratory-exchange and electromyography (EMG analysis. Intervention group participants subsequently performed three identical strength training (ST sessions, in the space of five days, repeating all assessments 24 h following the final ST. The control group completed the same testing procedure but with no ST. Following ST, the intervention group experienced significant elevations in soreness and CK activity, and decrements in MVC, SSJ, CMJ and PS (p < 0.01. However, 2,000 m rowing performance, pacing strategy and gas exchange were unchanged across trials in either condition. Following ST, significant increases occurred for EMG (p < 0.05, and there were non-significant trends for decreased blood lactate and anaerobic energy liberation (p = 0.063 – 0.086. In summary, club-standard rowers, following an intensive period of strength training, maintained their 2,000 m rowing performance despite suffering symptoms of muscle damage and disruption to muscle function. This disruption likely reflected the presence of acute residual fatigue, potentially in type II muscle fibres as strength and power development were affected.

  9. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs.

    Science.gov (United States)

    Dorweiler, Matthew A; Van Dyke, Rufus O; Siska, Robert C; Boin, Michael A; DiPaola, Mathew J

    2017-05-01

    Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Controlled laboratory study. Eighteen cadaver arms were randomized into 2 groups. One group received the anchorless repair and the other received the knotless anchor repair. A materials testing system (MTS) machine was used to cycle the repaired arms from 0° to 90° with a 2.5-pound weight for 1500 cycles at 0.25 Hz. Real-time displacement of the tendon was measured during cycling using a probe. Load to failure was performed after completion of cyclic loading. The mean displacement with the anchorless technique was 0.77 mm (SD, 0.25 mm) at 0° (full elbow extension) and 0.76 mm (SD, 0.38 mm) at 90° (elbow flexion). The mean displacement with the anchored technique was 0.83 mm (SD, 0.57 mm) at 0° and 1.01 mm (SD, 0.62 mm) at 90°. There was no statistically significant difference for tendon displacement at 0º ( P = .75) or 90º ( P = .31). The mean load to failure with the anchorless technique was 618.9 N (SD, 185.6 N), while it was 560.5 N (SD, 154.1 N) with the anchored technique, again with no statistically significant difference ( P = .28). Our anchorless double-row triceps repair technique yields comparable biomechanical properties to previously described double-row triceps tendon repair techniques, with the added benefit of avoiding the cost of suture anchors. This anchorless double-row triceps tendon repair can be considered as an acceptable alternative to a knotless anchor repair for triceps tendon ruptures.

  10. The chemistry of ultra-low concentrations

    International Nuclear Information System (INIS)

    Vertes, Attila; Kiss, Istvan

    1987-01-01

    Methods for the separation and enrichment of radionuclides in the ultra-low concentration range (coprecipitation, adsorption of radioactive substances on crystals) are disscussed in this chapter of the textbook. The properties and behaviour of ultra-dilute solutions, radiocolloids and the electrochemistry of ultra-dilute solution are also overviewed

  11. [Rotator cuff repair: single- vs double-row. Clinical and biomechanical results].

    Science.gov (United States)

    Baums, M H; Kostuj, T; Klinger, H-M; Papalia, R

    2016-02-01

    The goal of rotator cuff repair is a high initial mechanical stability as a requirement for adequate biological recovery of the tendon-to-bone complex. Notwithstanding the significant increase in publications concerning the topic of rotator cuff repair, there are still controversies regarding surgical technique. The aim of this work is to present an overview of the recently published results of biomechanical and clinical studies on rotator cuff repair using single- and double-row techniques. The review is based on a selective literature research of PubMed, Embase, and the Cochrane Database on the subject of the clinical and biomechanical results of single- and double-row repair. In general, neither the biomechanical nor the clinical evidence can recommend the use of a double-row concept for the treatment for every rotator cuff tear. Only tears of more than 3 cm seem to benefit from better results on both imaging and in clinical outcome studies compared with the use of single-row techniques. Despite a significant increase in publications on the surgical treatment of rotator cuff tears in recent years, the clinical results were not significantly improved in the literature so far. Unique information and algorithms, from which the optimal treatment of this entity can be derived, are still inadequate. Because of the cost-effectiveness and the currently vague evidence, the double-row techniques cannot be generally recommended for the repair of all rotator cuff tears.

  12. Historical development and current status of organ procurement from death-row prisoners in China.

    Science.gov (United States)

    Allison, Kirk C; Caplan, Arthur; Shapiro, Michael E; Els, Charl; Paul, Norbert W; Li, Huige

    2015-12-03

    In December 2014, China announced that only voluntarily donated organs from citizens would be used for transplantation after January 1, 2015. Many medical professionals worldwide believe that China has stopped using organs from death-row prisoners. In the present article, we briefly review the historical development of organ procurement from death-row prisoners in China and comprehensively analyze the social-political background and the legal basis of the announcement. The announcement was not accompanied by any change in organ sourcing legislations or regulations. As a fact, the use of prisoner organs remains legal in China. Even after January 2015, key Chinese transplant officials have repeatedly stated that death-row prisoners have the same right as regular citizens to "voluntarily donate" organs. This perpetuates an unethical organ procurement system in ongoing violation of international standards. Organ sourcing from death-row prisoners has not stopped in China. The 2014 announcement refers to the intention to stop the use of organs illegally harvested without the consent of the prisoners. Prisoner organs procured with "consent" are now simply labelled as "voluntarily donations from citizens". The semantic switch may whitewash sourcing from both death-row prisoners and prisoners of conscience. China can gain credibility only by enacting new legislation prohibiting use of prisoner organs and by making its organ sourcing system open to international inspections. Until international ethical standards are transparently met, sanctions should remain.

  13. Current development of cardiac imaging with multidetector-row CT

    International Nuclear Information System (INIS)

    Becker, Christoph R.; Ohnesorge, Bernd M.; Schoepf, U. Joseph; Reiser, Maximilian F.

    2000-01-01

    Multidector-row CT (MDCT) with retrospective ECG gating allows scanning the entire heart with 1.25 mm slice thickness and 250 ms effective exposure time within 35 s investigation time. The resulting images allow for an accurate high-resolution assessment of morphological detail of both the coronary arteries and the cardiac chambers. Performing a contrast-enhanced MDCT angiography (MD-CTA) in addition to a non-enhanced scan for the detection and quantification of coronary calcifications may be indicated in patients with atypical chest pain and in young patients with high cardiovascular risk. This group of patients may show non-calcified plaques as the first sign of their coronary artery disease. As the proximal part of the coronary arteries is well displayed by MD-CTA it also helps to delineate the course in anomalous coronary vessels. Additional information is drawn from the preoperative use of MD-CTA do determine the distance of the left internal mammarian artery to the left anterior descending coronary artery prior to minimal invasive bypass grafting. Additional indications for MD-CTA are the non-invasive follow up after venous bypass grafting, PTCA, and coronary stent interventions. MD-CTA allows following the course of the coronary vessels to the level of third generation coronary segmental arteries. A definite diagnosis to rule out coronary artery disease can be reliably made in vessels with a diameter of 1.5 mm or greater. With MDCT a number of different atherosclerotic changes can be observed in diseased coronary arteries. Non-stenotic lesions may show tiny calcifications surrounded by large areas of irregularly distributed soft tissue. Calcifications in this type of atherosclerotic coronary artery wall changes appear as 'the tip of iceberg'. Heavy calcifications usually tend to be non-stenotic because of vessel remodelling resulting in a widening of the coronary vessel lumen. Therefore, heavy calcifications appear to act like an 'internal stent' for a

  14. Influence of the initial rupture size and tendon subregion on three-dimensional biomechanical properties of single-row and double-row rotator cuff reconstructions.

    Science.gov (United States)

    Lorbach, O; Pape, D; Raber, F; Busch, L C; Kohn, D; Kieb, M

    2012-11-01

    Influence of the initial rotator cuff tear size and of different subregions of the SSP tendon on the cyclic loading behavior of a modified single-row reconstruction compared to a suture-bridging double-row repair. Artificial tears (25 and 35 mm) were created in the rotator cuff of 24 human cadaver shoulders. The reconstructions were performed as a single-row repair (SR) using a modified suture configuration or a suture-bridge double-row repair (DR). Radiostereometric analysis was used under cyclic loading (50 cycles, 10–180 N, 10–250 N) to calculate cyclic displacement in three different planes (anteroposterior (x), craniocaudal (y) and mediolateral (z) level). Cyclic displacement was recorded, and differences in cyclic displacement of the anterior compared to the posterior subregions of the tendon were calculated. In small-to-medium tears (25 mm) and medium-to-large tears (35 mm), significant lower cyclic displacement was seen for the SR-reconstruction compared to the DR-repair at 180 N (p ≤ 0.0001; p = 0.001) and 250 N (p = 0.001; p = 0.007) in the x-level. These results were confirmed in the y-level at 180 N (p = 0.001; p = 0.0022) and 250 N (p = 0.005; p = 0.0018). Comparison of the initial tear sizes demonstrated significant differences in cyclic displacement for the DR technique in the x-level at 180 N (p = 0.002) and 250 N (p = 0.004). Comparison of the anterior versus the posterior subregion of the tendon revealed significant lower gap formation in the posterior compared to the anterior subregions in the x-level for both tested rotator cuff repairs (p ≤ 0.05). The tested single-row repair using a modified suture configuration achieved superior results in three-dimensional measurements of cyclic displacement compared to the tested double-row suture-bridge repair. The results were dependent on the initial rupture size of the rotator cuff tear. Furthermore, significant differences were found between tendon subregions of the rotator cuff with

  15. Mechanisms for Triceps Surae Injury in High Performance Front Row Rugby Union Players: A Kinematic Analysis of Scrummaging Drills

    OpenAIRE

    Flavell, Carol A.; Sayers, Mark G. L.; Gordon, Susan J.; Lee, James B.

    2013-01-01

    The front row of a rugby union scrum consists of three players. The loose head prop, hooker and tight head prop. The objective of this study was to determine if known biomechanical risk factors for triceps surae muscle injury are exhibited in the lower limb of front row players during contested scrummaging. Eleven high performance front row rugby union players were landmarked bilaterally at the posterior superior iliac spine (PSIS), greater trochanter, lateral femoral epicondyle, midline of t...

  16. The effect of sowing strategy, row distance and mechanical weed control on weeds and yield in organic winter wheat

    OpenAIRE

    Rasmussen, Ilse A.

    2002-01-01

    A series of field experiments were carried out in winter wheat grown under organic conditions in Denmark on fields with different weed pressure. The treatments were sowing strategy (normal sowing time, late sowing and false seedbed), row distance (12 cm and 24 cm row distance) and weed control method (untreated, mechanical weed control (weed harrowing at 12 cm supplemented with row hoeing at 24 cm), and herbicide weed control). Weed biomass was largest at the normal sowing time and was reduce...

  17. Are narrow mesons, baryons and dibaryons evidence for multiquark states?

    International Nuclear Information System (INIS)

    Tatischeff, B.; Yonnet, J.

    2000-01-01

    Several narrow structures have been progressively observed since the last fifteen years, in di-baryonic invariant mass spectra or in missing mass spectra. More recently, narrow structures were observed in baryonic and now in mesonic mass spectra. Since these small peaks appear at fixed masses, independently of the experiment, they are associated with real states. There is no room to explain these states within classical nuclear physics taking into account baryonic and mesonic degrees of freedom. An interpretation is proposed, which associate these narrow structures with two coloured quark clusters. (authors)

  18. Impact of multi-detector row computed tomography on the tactics of cardiovascular surgery. From qualitative evaluation to quantitative assessment

    International Nuclear Information System (INIS)

    Imagawa, Hiroshi; Kawachi, Kanji; Takano, Shinji

    2005-01-01

    We assessed the role of multi-detector row computed tomography in cardiovascular surgery. The efficacy of multi-detector row computed tomography was assessed concerning the graft patency of coronary artery bypass, arterial atheromatous degeneration, small vessel imaging, and left ventricular volume measurement. Images were reconstructed using both the volume-rendering and the maximum-intensity-profile methods. Arterial atherosclerotic degeneration was assessed by aortic wall volume and aortic calcification volume. In the assessment of bypass graft patency, multidetector row computed tomography showed a 98% correct positive ratio with sensitivity and specificity of 98% and 100%, respectively. Atheromatous degeneration showed matching results in more than 70% of cases compared with intraoperative findings. More than 92% of arterial branches with diameters of 3 mm or greater were detected by preoperative multi-detector row computed tomography images, though only 6% of branches with diameters of 2 mm or less could be visualized. There was a positive linear correlation between left ventricular volumes determined by multi-detector row computed tomography and those calculated from cine angiography. Multi-detector row computed tomography clearly visualized coronary bypass grafts and aortic arterial branches, providing detailed vascular images. Atheromatous degeneration assessed by multi-detector row computed tomography was equivalent with intraoperative findings in more than 70% of cases. Left ventricular volumes measured by multi-detector row computed tomography correlated closely with those determined by cine-angiography. Multidetector row computed tomography is an efficient and promising modality in cardiovascular surgery. (author)

  19. Identification of AFLP molecular linked to row- type gene in barley

    International Nuclear Information System (INIS)

    Sayed- Tabatabaei, B.E.

    2005-01-01

    Formation of the two-and six-rowed types in barley is predominantly controlled by alleles at a single locus (vrzl) which is located in long armn of chromosome 2H. This gene is a key character on the study of barley domestication and yield. Near-isogenic lines of barley were produced from crosses between Kanto Nakate Gold (tow-rowed) and Azumamugi (six-rowed). The selected lines were used for screening of AFLP polymorphic bands which are linked to vrs1 locus. After screening of a total of 1792 primer combination, five polymorphic bands were identified. A construction of high resolution map around the vrs1 locus was made using recombinant inbred lines. These markers can be used for a map-based cloning of the genes at the vrsl locus

  20. The Passive Microwave Remote Sensing of Soil Moisture: the Effect of Tilled Row Structure

    Science.gov (United States)

    Wang, J. R.; Newton, R. W.; Rouse, J. W.

    1979-01-01

    The tilled rowstructure is known to be one of the important factors affecting the observations of the microwave emission from a natural surface. Measurements of this effect were carried out with both I and X band radiometers mounted on a mobile truck on a bare 40 m x 45 m row tilled field. The soil moisture content during the measurements ranged from approximately 10 percent to approximately 30 percent by dry weight. The results of these measurements showed that the variations of the antenna temperatures with incident angle theta changed with the azimuthal angle a measured from the row direction. A numerical calculation based on a composite surface roughness was made and found to predict the observed features within the model's limit of accuracy. It was concluded that the difference between the horizontally and vertically polarized temperatures was due to the change in the local angle of field emission within the antenna field of view caused by the large scale row structure.

  1. Analysis of Power Enhancement for a Row of Wind Turbines Using the Actuator Line Technique

    International Nuclear Information System (INIS)

    Mikkelsen, Robert; Soerensen, Jens N; Oeye, Stig; Troldborg, Niels

    2007-01-01

    The effect of wake interaction for a row of three wind turbines in a wind farm is analysed using the actuator line technique. Both full wake and half wake situations are considered with the aim of deriving the optimal pitch setting of the foremost turbine, with respect to the total power from the row. The mutual distance between the turbines is 5 diameters and the turbines are considered to operate in a wind shear with an exponent of 0.15, with the rotor centre located at 1.4 radii from the ground. The main findings reveal clear effects of reducing the loading on the foremost turbine towards increased production of turbine 2 and 3 in a row

  2. IMPACT OF ROW-PLANTING ADOPTION ON PRODUCTIVITY OF RICE FARMING IN NORTHERN GHANA

    Directory of Open Access Journals (Sweden)

    Emmanuel DONKOR

    2016-11-01

    Full Text Available This paper employed the endogenous switching regression and propensity score matching methods to analyse the impact of row-planting technology on rice productivity using 470 rice farms in Northern Ghana. The empirical findings showed that the adoption of row-planting technology exerted greater positive impact on rice yields of smallholder farmers. In addition, rice yields of adopters and non-adopters are driven by farm inputs, socioeconomic, institutional and technological factors. We suggest that achieving self-sufficiency in rice and rural economic transformation in sub-Saharan Africa requires promotion of agricultural technologies including row-planting. Different specific policy interventions are also required to promote rice yields for adopters and non-adopters.

  3. Investigation of Blade-row Flow Distributions in Axial-flow-compressor Stage Consisting of Guide Vanes and Rotor-blade Row

    Science.gov (United States)

    Mahoney, John J; Dugan, Paul D; Budinger, Raymond E; Goelzer, H Fred

    1950-01-01

    A 30-inch tip-diameter axial-flow compressor stage was investigated with and without rotor to determine individual blade-row performance, interblade-row effects, and outer-wall boundary-layer conditions. Velocity gradients at guide-vane outlet without rotor approximated design assumptions, when the measured variation of leaving angle was considered. With rotor in operation, Mach number and rotor-blade effects changed flow distribution leaving guide vanes and invalidated design assumption of radial equilibrium. Rotor-blade performance correlated interpolated two-dimensional results within 2 degrees, although tip stall was indicated in experimental and not two-dimensional results. Boundary-displacement thickness was less than 1.0 and 1.5 percent of passage height after guide vanes and after rotor, respectively, but increased rapidly after rotor when tip stall occurred.

  4. What's in a name? Expiratory tracheal narrowing in adults explained

    International Nuclear Information System (INIS)

    Leong, P.; Bardin, P.G.; Lau, K.K.

    2013-01-01

    Tracheomalacia, tracheobronchomalacia, and excessive dynamic airway collapse are all terms used to describe tracheal narrowing in expiration. The first two describe luminal reduction from cartilage softening and the latter refers to luminal reduction from exaggerated posterior membrane movement. Expiratory tracheal narrowing is a frequent occurrence that can cause symptoms of airway obstruction, such as dyspnoea, wheeze, and exercise intolerance. The accurate diagnosis and quantification of expiratory tracheal narrowing has important aetiological, therapeutic, and prognostic implications. The reference standard for diagnosis has traditionally been bronchoscopy; however, this method has significant limitations. Expiratory tracheal disorders are readily detected by four-dimensional dynamic volume multidetector computed tomography (4D-CT), an emerging, non-invasive method that will potentially enable detection and quantification of these conditions. This review discusses the morphological forms of expiratory tracheal narrowing and demonstrates the utility of 4D-CT in the diagnosis, quantification, and treatment of these important conditions

  5. Single frequency narrow linewidth 2 micron laser, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA needs narrow linewidth lasers in the 1.5 or 2 micron wavelength regime for coherent Lidar applications. The laser should be tunable by several nm and frequency...

  6. Subglottic cysts and asymmetrical subglottic narrowing on neck radiograph

    International Nuclear Information System (INIS)

    Holinger, L.D.; Torium, D.M.; Anandappa, E.C.

    1988-01-01

    The congenital subglottic hemangioma typically appears as an asymmetric subglottic narrowing or mass on frontal neck radiograph. Therefore, soft tissue neck radiography has been advocated as a definitive non-operative approach for diagnosing these lesions. However, we have noted similar asymmetric subglottic narrowing in patients with acquired subglottic cysts. These retention cysts occur following long-term intubation in the neonate. The mechanism probably involves subglottic fibrosis which obstructs glands with subsequent cyst formation. Acquired subglottic cysts typically appear as an asymmetric narrowing on frontal or lateral soft tissue neck radiographs. These lesions may produce airway compromise but are effectively treated by forceps or laser removal. Acquired subglottic cysts must be included in the differential diagnosis of asymmetric subglottic narrowing. The definitive diagnosis is made by direct laryngoscopy, not soft tissue neck radiograph. (orig.)

  7. THE TREATMENT OF OPEN- AND NARROW-ANGLE GLAUCOMA

    African Journals Online (AJOL)

    1971-04-10

    Apr 10, 1971 ... glaucoma will be considered: narrow-angle glaucoma. (acute glaucoma) and ... emotional or a physical crisis. The pain is in the distribu- .... ness, not increased pressure, haunts people suffering from glaucoma'.' The saga of ...

  8. Comment on the narrow structure reported by Amaryan et al

    OpenAIRE

    Anghinolfi, M.; Ball, J.; Baltzell, N. A.; Battaglieri, M.; Bedlinskiy, I.; Bellis, M.; Biselli, A. S.; Bookwalter, C.; Boiarinov, S.; Bosted, P.; Burkert, V. D.; Carman, D. S.; Celentano, A.; Chandavar, S.; Cole, P. L.

    2012-01-01

    The CLAS Collaboration provides a comment on the physics interpretation of the results presented in a paper published by M. Amaryan et al. regarding the possible observation of a narrow structure in the mass spectrum of a photoproduction experiment.

  9. Narrow band interference cancelation in OFDM: Astructured maximum likelihood approach

    KAUST Repository

    Sohail, Muhammad Sadiq; Al-Naffouri, Tareq Y.; Al-Ghadhban, Samir N.

    2012-01-01

    This paper presents a maximum likelihood (ML) approach to mitigate the effect of narrow band interference (NBI) in a zero padded orthogonal frequency division multiplexing (ZP-OFDM) system. The NBI is assumed to be time variant and asynchronous

  10. Editorial Commentary: "Knot" Less Strength at Half the Cost-Is It Time to Abandon Medial Row Anchors in Shoulder Double-Row Rotator Cuff Repair?

    Science.gov (United States)

    Sherman, Seth L

    2018-01-01

    Transosseous equivalent rotator cuff repair is an expensive construct that has demonstrated biomechanical superiority when compared with other rotator cuff repair techniques. A novel transosseous knotless repair that substitutes medial row anchors for a transosseous tunnel rivals the biomechanical advantages of transosseous equivalent rotator cuff repair at half the cost and with reduced dependence on bone quality. Surgeons should carefully consider if "knotless transosseous is more." Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  11. Ultra-broadband carpet cloak for transverse-electric polarization

    International Nuclear Information System (INIS)

    Deng, Ye; Xu, Su; Zhang, Runren; Zheng, Bin; Chen, Hongsheng; Chen, Hua; Yu, Faxin; Gao, Fei; Zhang, Baile

    2016-01-01

    Magnetism is a necessity in constructing macroscopic metamaterial invisibility cloaks that are theoretically designed by transformation optics, but will generally limit the cloaking bandwidth to an impractically narrow range. To meet the broad bandwidth demand, magnetism has been fully abandoned in previous demonstrations of macroscopic carpet cloaking, whose approach, however, cannot apply to a transverse-electric (TE) polarization. To fill this gap, here we experimentally demonstrate an ultra-broadband magnetic carpet cloak for the TE polarization. The cloak is made of non-resonant closed-ring metamaterials with little dispersion and the cloaking performance is confirmed with both time-domain simulation and frequency scanning measurement over a broad bandwidth corresponding to a pulse signal illumination. (paper)

  12. Ultra-broadband carpet cloak for transverse-electric polarization

    Science.gov (United States)

    Deng, Ye; Xu, Su; Zhang, Runren; Zheng, Bin; Chen, Hua; Gao, Fei; Yu, Faxin; Zhang, Baile; Chen, Hongsheng

    2016-04-01

    Magnetism is a necessity in constructing macroscopic metamaterial invisibility cloaks that are theoretically designed by transformation optics, but will generally limit the cloaking bandwidth to an impractically narrow range. To meet the broad bandwidth demand, magnetism has been fully abandoned in previous demonstrations of macroscopic carpet cloaking, whose approach, however, cannot apply to a transverse-electric (TE) polarization. To fill this gap, here we experimentally demonstrate an ultra-broadband magnetic carpet cloak for the TE polarization. The cloak is made of non-resonant closed-ring metamaterials with little dispersion and the cloaking performance is confirmed with both time-domain simulation and frequency scanning measurement over a broad bandwidth corresponding to a pulse signal illumination.

  13. Narrow Framing and Long-Term Care Insurance

    OpenAIRE

    Daniel Gottlieb; Olivia S. Mitchell

    2015-01-01

    We propose a model of narrow framing in insurance and test it using data from a new module we designed and fielded in the Health and Retirement Study. We show that respondents subject to narrow framing are substantially less likely to buy long-term care insurance than average. This effect is distinct from, and much larger than, the effects of risk aversion or adverse selection, and it offers a new explanation for why people underinsure their later-life care needs.

  14. Utilising scripting language for unmanned and automated guided vehicles operating within row crops

    DEFF Research Database (Denmark)

    Jørgensen, R. N.; Nørremark, M.; Sørensen, C.G.

    2008-01-01

    A flexible high-level control language is an important element in the ongoing task of introducing automated guided vehicles (AGV) to new application domains. A new application domain is row crops, where small AGV's will perform weed control around individual crop plants. This paper defines...... is described here as the ‘supervisory field coverage monitor’ (SFCM), which acts to coordinate the behaviours. The applicability of this modified SMR-CL has been successfully demonstrated using a vehicle test in a specially designed artificial row crop field. The analysis of the operational performance...

  15. Use of multidetector row CT with volume renderings in right lobe living liver transplantation

    International Nuclear Information System (INIS)

    Ishifuro, Minoru; Akiyama, Yuji; Kushima, Toshio; Horiguchi, Jun; Nakashige, Aya; Tamura, Akihisa; Marukawa, Kazushi; Fukuda, Hiroshi; Ono, Chiaki; Ito, Katsuhide

    2002-01-01

    Multidetector row CT is a feasible diagnostic tool in pre- and postoperative liver partial transplantation. We can assess vascular anatomy and liver parenchyma as well as volumetry, which provide useful information for both donor selection and surgical planning. Disorders of the vascular and biliary systems are carefully observed in recipients. In addition, we evaluate liver regeneration of both the donor and the recipient by serial volumetry. We present how multidetector row CT with state-of-the-art three-dimensional volume renderings may be used in right lobe liver transplantation. (orig.)

  16. Sorption of chrysoidine by row cork and cork entrapped in calcium alginate beads

    Directory of Open Access Journals (Sweden)

    Valeria M. Nurchi

    2014-01-01

    The influence on the sorption of pH, initial dye concentration, and particle size, as well as the efficiency of the entrapment, have been investigated. The maximum sorption was found for cork samples of fine particle size (FC, in both row and entrapped forms, at pH 7; conversely, at pH 4 the difference is significant (0.12 mmol/g for row cork and 0.20 mmol/g for entrapped cork, evoking a cooperation of alginate in binding the positively charged chrysoidine molecule.

  17. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  18. Determination of the neutron flux for the Yankee Rowe experiment in the Ford Nuclear Reactor

    International Nuclear Information System (INIS)

    Cacciapouti, R.J.; Petrusha, L.

    1994-01-01

    Yankee Atomic Electric Company undertook a Test Irradiation Program at the Ford Nuclear Reactor of the University of Michigan. The program was implemented to characterize the irradiation response of representative Yankee Rowe reactor vessel beltline plate materials. The program was also intended to remove uncertainties in the existing reactor vessel fluence and damage predictions on the Yankee Rowe reactor vessel steel. Since this is the first in-core experiment of this type for the Ford Nuclear Reactor, the measurement of the reaction rate and the estimate of the fluence are presented

  19. Locomotion on the water surface: hydrodynamic constraints on rowing velocity require a gait change

    Science.gov (United States)

    Suter; Wildman

    1999-10-01

    Fishing spiders, Dolomedes triton (Araneae, Pisauridae), propel themselves across the water surface using two gaits: they row with four legs at sustained velocities below 0.2 m s(-)(1) and they gallop with six legs at sustained velocities above 0.3 m s(-)(1). Because, during rowing, most of the horizontal thrust is provided by the drag of the leg and its associated dimple as both move across the water surface, the integrity of the dimple is crucial. We used a balance, incorporating a biaxial clinometer as the transducer, to measure the horizontal thrust forces on a leg segment subjected to water moving past it in non-turbulent flow. Changes in the horizontal forces reflected changes in the status of the dimple and showed that a stable dimple could exist only under conditions that combined low flow velocity, shallow leg-segment depth and a long perimeter of the interface between the leg segment and the water. Once the dimple disintegrated, leaving the leg segment submerged, less drag was generated. Therefore, the disintegration of the dimple imposes a limit on the efficacy of rowing with four legs. The limited degrees of freedom in the leg joints (the patellar joints move freely in the vertical plane but allow only limited flexion in other planes) impose a further constraint on rowing by restricting the maximum leg-tip velocity (to approximately 33 % of that attained by the same legs during galloping). This confines leg-tip velocities to a range at which maintenance of the dimple is particularly important. The weight of the spider also imposes constraints on the efficacy of rowing: because the drag encountered by the leg-cum-dimple is proportional to the depth of the dimple and because dimple depth is proportional to the supported weight, only spiders with a mass exceeding 0.48 g can have access to the full range of hydrodynamically possible dimple depths during rowing. Finally, the maximum velocity attainable during rowing is constrained by the substantial drag

  20. Ocular Biometrics of Myopic Eyes With Narrow Angles.

    Science.gov (United States)

    Chong, Gabriel T; Wen, Joanne C; Su, Daniel Hsien-Wen; Stinnett, Sandra; Asrani, Sanjay

    2016-02-01

    The purpose of this study was to compare the ocular biometrics between myopic patients with and without narrow angles. Patients with a stable myopic refraction (myopia worse than -1.00 D spherical equivalent) were prospectively recruited. Angle status was assessed using gonioscopy and biometric measurements were performed using an anterior segment optical coherence tomography and an IOLMaster. A total of 29 patients (58 eyes) were enrolled with 13 patients (26 eyes) classified as having narrow angles and 16 patients (32 eyes) classified as having open angles. Baseline demographics of age, sex, and ethnicity did not differ significantly between the 2 groups. The patients with narrow angles were on average older than those with open angles but the difference did not reach statistical significance (P=0.12). The central anterior chamber depth was significantly less in the eyes with narrow angles (P=0.05). However, the average lens thickness, although greater in the eyes with narrow angles, did not reach statistical significance (P=0.10). Refractive error, axial lengths, and iris thicknesses did not differ significantly between the 2 groups (P=0.32, 0.47, 0.15). Narrow angles can occur in myopic eyes. Routine gonioscopy is therefore recommended for all patients regardless of refractive error.

  1. Acquisition and visualization techniques for narrow spectral color imaging.

    Science.gov (United States)

    Neumann, László; García, Rafael; Basa, János; Hegedüs, Ramón

    2013-06-01

    This paper introduces a new approach in narrow-band imaging (NBI). Existing NBI techniques generate images by selecting discrete bands over the full visible spectrum or an even wider spectral range. In contrast, here we perform the sampling with filters covering a tight spectral window. This image acquisition method, named narrow spectral imaging, can be particularly useful when optical information is only available within a narrow spectral window, such as in the case of deep-water transmittance, which constitutes the principal motivation of this work. In this study we demonstrate the potential of the proposed photographic technique on nonunderwater scenes recorded under controlled conditions. To this end three multilayer narrow bandpass filters were employed, which transmit at 440, 456, and 470 nm bluish wavelengths, respectively. Since the differences among the images captured in such a narrow spectral window can be extremely small, both image acquisition and visualization require a novel approach. First, high-bit-depth images were acquired with multilayer narrow-band filters either placed in front of the illumination or mounted on the camera lens. Second, a color-mapping method is proposed, using which the input data can be transformed onto the entire display color gamut with a continuous and perceptually nearly uniform mapping, while ensuring optimally high information content for human perception.

  2. Intramyocardial arterial narrowing in dogs with subaortic stenosis.

    Science.gov (United States)

    Falk, T; Jönsson, L; Pedersen, H D

    2004-09-01

    Earlier studies have described intramyocardial arterial narrowing based on hyperplasia and hypertrophy of the vessel wall in dogs with subaortic stenosis (SAS). In theory, such changes might increase the risk of sudden death, as they seem to do in heart disease in other species. This retrospective pathological study describes and quantifies intramyocardial arterial narrowing in 44 dogs with naturally occurring SAS and in eight control dogs. The majority of the dogs with SAS died suddenly (n=27); nine had died or been euthanased with signs of heart failure and eight were euthanased without clinical signs. Dogs with SAS had significantly narrower intramyocardial arteries (Pdogs. Male dogs and those with more severe hypertrophy had more vessel narrowing (P=0.02 and P=0.02, respectively), whereas dogs with dilated hearts had slightly less pronounced arterial thickening (P=0.01). Arterial narrowing was not related to age, but fibrosis increased with age (P=0.047). Dogs that died suddenly did not have a greater number of arterial changes than other dogs with SAS. This study suggests that most dogs with SAS have intramyocardial arterial narrowing and that the risk of dying suddenly is not significantly related to the overall degree of vessel obliteration.

  3. Effects of Row Spacing and Plant Density on Yield and Yield Components of Sweet Corn in Climatic Conditions of Isfahan

    Directory of Open Access Journals (Sweden)

    N. Khodaeian

    2013-06-01

    Full Text Available To evaluate the effects of row spacing and plant density on yield and yield components of sweet corn, variety KSC403, an experiment was conducted in Research Farm of Isfahan University of Technology, Isfahan, Iran, in 2007, as randomized complete block design with a split-plot layout and three replications. The main plots were allocated to two row spacing (60 and 75 cm and the sub-plots accommodated four levels of plant density (50000, 70000, 90000 and 110000 plants per ha. There was significant increase in leaf area index, shoot dry weight, 100-grain fresh weight and grain fresh yield, as row width was decreased from 75 to 60 cm but the plant height was decreased. There was no significant effect of row spacing on number of rows per ear, number of grains per row and number of grains per ear. Plant height, leaf area index, shoot dry weight per m2 and number of ears per m2 were increased with an increase in plant density. The number of rows per ear, number of grains per row, number of grains per ear, 100-grain fresh weight and grain fresh yield were significantly higher under plant densities of 90000 and 110000 as compared to 50000 and 70000 plants per ha. There was significant interaction between row spacing and plant density for leaf area index, shoot dry weight, number of grains per ear, 100-grain fresh weight and grain fresh yield. Under all plant densities, the grain fresh yield was higher in 60-cm row width compared to 70-cm row width. However, the difference between these two row spacing was not significant in plant densities of 50000 and 110000 plants per ha. The highest grain fresh yield (33940 kg/ha was achieved under row spacing 60 cm and 70000 plants per ha and the least grain fresh yield (20750 kg/ha was obtained in under 75 cm row width and 110000 plants per ha. Considering the obtained results of this experiment, to have maximum grain fresh yield of sweet corn under Isfahan climate, the row spacing of 60 cm and plant density of

  4. Assessment of temporal resolution of multi-detector row computed tomography in helical acquisition mode using the impulse method.

    Science.gov (United States)

    Ichikawa, Katsuhiro; Hara, Takanori; Urikura, Atsushi; Takata, Tadanori; Ohashi, Kazuya

    2015-06-01

    The purpose of this study was to propose a method for assessing the temporal resolution (TR) of multi-detector row computed tomography (CT) (MDCT) in the helical acquisition mode using temporal impulse signals generated by a metal ball passing through the acquisition plane. An 11-mm diameter metal ball was shot along the central axis at approximately 5 m/s during a helical acquisition, and the temporal sensitivity profile (TSP) was measured from the streak image intensities in the reconstructed helical CT images. To assess the validity, we compared the measured and theoretical TSPs for the 4-channel modes of two MDCT systems. A 64-channel MDCT system was used to compare TSPs and image quality of a motion phantom for the pitch factors P of 0.6, 0.8, 1.0 and 1.2 with a rotation time R of 0.5 s, and for two R/P combinations of 0.5/1.2 and 0.33/0.8. Moreover, the temporal transfer functions (TFs) were calculated from the obtained TSPs. The measured and theoretical TSPs showed perfect agreement. The TSP narrowed with an increase in the pitch factor. The image sharpness of the 0.33/0.8 combination was inferior to that of the 0.5/1.2 combination, despite their almost identical full width at tenth maximum values. The temporal TFs quantitatively confirmed these differences. The TSP results demonstrated that the TR in the helical acquisition mode significantly depended on the pitch factor as well as the rotation time, and the pitch factor and reconstruction algorithm affected the TSP shape. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: Prospective comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Li Xiaoming; Li Yuhua; Tian Jianming; Xiao Yi; Lu Jianping; Jing Zaiping; Sheng Jing; Edwin, Angela; Wu Fanghong

    2010-01-01

    Purpose: To assess the accuracy of 64-slice multi-detector row computed tomography (MDCT) angiography in the evaluation of peripheral artery in-stent or peristent restenosis, with conventional digital subtraction angiography (DSA) as the reference standard. Materials and methods: Forty-one patients (30 men, 11 women; mean age, 69.8 ± 9.2 years) with symptomatic peripheral arterial occlusive disease after peripheral artery stenting (81 stented lesions) underwent both conventional DSA and 64-slice MDCT angiography. Each stent was classified as evaluable or unevaluable, and every stent was divided into three segments (proximal stent, stent body, and distal stent), resulting in 243 segments. For evaluation, stenosis was graded as follows: 1, none or slight stenosis (<25%); 2, mild stenosis (25-49%); 3, moderate stenosis (50-74%); 4, severe stenosis or total occlusion (≥75%). Two readers evaluated all CT angiograms with regard to narrowing of in-stent or peristent restenosis by consensus. Results were compared with findings of the DSA. Results: Of 81 stents, 62 (76.5%) were determined to be assessable. The metal artifact of the gold marker and motion artifact increased uninterpretability of the images of stents. Overall, 24 of 28 in-stent restenosis and 38 of 53 persistent restenosis were correctly detected by MDCT (85.7% and 71.7% sensitivity). In evaluable stents, 21 of 22 in-stent restenoses and 27 of 28 persistent restenosis were correctly detected (95.4% and 96.4% sensitivity). Additionally, as the grade of stenosis increases, the mean level of CT values in the stent lumina decreases linearly accordingly. Conclusion: 64-Slice MDCT has a high accuracy for the detection of significant in-stent or peristent restenosis of assessable stents in patients with peripheral artery stent implantation and therefore can be considered as a valuable noninvasive technique for stent surveillance.

  6. Narrow plasmon resonances enabled by quasi-freestanding bilayer epitaxial graphene

    Science.gov (United States)

    Daniels, Kevin M.; Jadidi, M. Mehdi; Sushkov, Andrei B.; Nath, Anindya; Boyd, Anthony K.; Sridhara, Karthik; Drew, H. Dennis; Murphy, Thomas E.; Myers-Ward, Rachael L.; Gaskill, D. Kurt

    2017-06-01

    Exploiting the underdeveloped terahertz range (~1012-1013 Hz) of the electromagnetic spectrum could advance many scientific fields (e.g. medical imaging for the identification of tumors and other biological tissues, non-destructive evaluation of hidden objects or ultra-broadband communication). Despite the benefits of operating in this regime, generation, detection and manipulation have proven difficult, as few materials have functional interactions with THz radiation. In contrast, graphene supports resonances in the THz regime through structural confinement of surface plasmons, which can lead to enhanced absorption. In prior work, the achievable plasmon resonances in such structures have been limited by multiple electron scattering mechanisms (i.e. large carrier scattering rates) which greatly broaden the resonance (>100 cm-1 3 THz). We report the narrowest room temperature Drude response to-date, 30 cm-1 (0.87 THz), obtained using quasi-free standing bilayer epitaxial graphene (QFS BLG) synthesized on (0 0 0 1)6H-SiC. This narrow response is due to a 4-fold increase in carrier mobility and improved thickness and electronic uniformity of QFS BLG. Moreover, QFS BLG samples patterned into microribbons targeting 1.8-5.7 THz plasmon resonances also exhibit low scattering rates (37-53 cm-1). Due to the improved THz properties of QFS BLG, the effects of e-beam processing on carrier scattering rates was determined and we found that fabrication conditions can be tuned to minimize the impact on optoelectronic properties. In addition, electrostatic gating of patterned QFS BLG shows narrow band THz amplitude modulation. Taken together, these properties of QFS BLG should facilitate future development of THz optoelectronic devices for monochromatic applications.

  7. A CHF Model in Narrow Gaps under Saturated Boiling

    International Nuclear Information System (INIS)

    Park, Suki; Kim, Hyeonil; Park, Cheol

    2014-01-01

    Many researchers have paid a great attention to the CHF in narrow gaps due to enormous industrial applications. Especially, a great number of researches on the CHF have been carried out in relation to nuclear safety issues such as in-vessel retention for nuclear power plants during a severe accident. Analytical studies to predict the CHF in narrow gaps have been also reported. Yu et al. (2012) developed an analytical model to predict the CHF on downward facing and inclined heaters based on the model of Kandlikar et al. (2001) for an upward facing heater. A new theoretical model is developed to predict the CHF in narrow gaps under saturated pool boiling. This model is applicable when one side of coolant channels or both sides are heated including the effects of heater orientation. The present model is compared with the experimental CHF data obtained in narrow gaps. A new analytical CHF model is proposed to predict CHF for narrow gaps under saturated pool boiling. This model can be applied to one-side or two-sides heating surface and also consider the effects of heater orientation on CHF. The present model is compared with the experimental data obtained in narrow gaps with one heater. The comparisons indicate that the present model shows a good agreement with the experimental CHF data in the horizontal annular tubes. However, it generally under-predicts the experimental data in the narrow rectangular gaps except the data obtained in the gap thickness of 10 mm and the horizontal downward facing heater

  8. The flow upstream of a row of aligned wind turbine rotors and its effect on power production

    DEFF Research Database (Denmark)

    Meyer Forsting, Alexander Raul; Troldborg, Niels; Gaunaa, Mac

    2017-01-01

    The blockage developing in front of a laterally aligned row of wind turbines and its impact on power production over a single turbine was analysed using two different numerical methods. The inflow direction was varied from orthogonal to the row until 45◦, with the turbines turning into the wind, ...

  9. Patterns of comb row development in young and adult stages of the ctenophores Mnemiopsis leidyi and Pleurobrachia pileus.

    Science.gov (United States)

    Tamm, Sidney L

    2012-09-01

    The development of comb rows in larval and adult Mnemiopsis leidyi and adult Pleurobrachia pileus is compared to regeneration of comb plates in these ctenophores. Late gastrula embryos and recently hatched cydippid larvae of Mnemiopsis have five comb plates in subsagittal rows and six comb plates in subtentacular rows. Subsagittal rows develop a new (sixth) comb plate and both types of rows add plates at similar rates until larvae reach the transition to the lobate form at ∼5 mm size. New plate formation then accelerates in subsagittal rows that later extend on the growing oral lobes to become twice the length of subtentacular rows. Interplate ciliated grooves (ICGs) develop in an aboral-oral direction along comb rows, but ICG formation itself proceeds from oral to aboral between plates. New comb plates in Mnemiopsis larvae are added at both aboral and oral ends of rows. At aboral ends, new plates arise as during regeneration: local widening of a ciliated groove followed by formation of a short split plate that grows longer and wider and joins into a common plate. At oral ends, new plates arise as a single tuft of cilia before an ICG appears. Adult Mnemiopsis continue to make new plates at both ends of rows. The frequency of new aboral plate formation varies in the eight rows of an animal and seems unrelated to body size. In Pleurobrachia that lack ICGs, new comb plates at aboral ends arise between the first and second plates as a single small nonsplit plate, located either on the row midline or off-axis toward the subtentacular plane. As the new (now second) plate grows larger, its distance from the first and third plates increases. Size of the new second plate varies within the eight rows of the same animal, indicating asynchronous formation of plates as in Mnemiopsis. New oral plates arise as in Mnemiopsis. The different modes of comb plate formation in Mnemiopsis versus Pleurobrachia are accounted for by differences in mesogleal firmness and mechanisms of

  10. The influence of row width and seed spacing on uniformity of plant spatial distributions

    DEFF Research Database (Denmark)

    Griepentrog, Hans W.; Olsen, Jannie Maj; Weiner, Jacob

    2009-01-01

    width and evenness of spacing within rows influences two-dimensional spatial quality. The results can be used to define new requirements for improved seeding technologies to achieve higher benefits in sustainable crop production systems. In general it can be concluded that more even plant distributions...... are expected to result in a better crop plant performance....

  11. Z-dependence of Mean Excitation Energies for Second and Third Row Atoms and Their Ions

    DEFF Research Database (Denmark)

    Sauer, Stephan P. A.; Sabin, John R.; Oddershede, Jens

    2018-01-01

    All mean excitations energies for second and third row atoms and their ions are calculated in the random‐phase approximation using large basis sets. To a very good approximation it turns out that mean excitation energies within an isoelectronic series is a quadratic function of the nuclear charge...

  12. Influence of Inter-Intra Row Spacing on Yield Losses of Tomato ...

    African Journals Online (AJOL)

    Data on major yield loss agents such as, blossom end rot, decay, insect, disease, sunburn, crack, catface and others minor disorders were collected; as well as total yield, percent of marketable and unmarketable fruit yield parameters were analyzed. Results of the study showed that inter-intra row spacing and cultivar had a ...

  13. 2-D Row-Column CMUT Arrays with an Open-Grid Support Structure

    DEFF Research Database (Denmark)

    Christiansen, Thomas Lehrmann; Dahl-Petersen, Christian; Jensen, Jørgen Arendt

    2013-01-01

    Fabrication and characterization of 64 + 64 2-D row-column addressed CMUT arrays with 250 μm element pitch and 4.4 MHz center frequency in air incorporating a new design approach is presented. The arrays are comprised of two wafer bonded, structured silicon-on-insulator wafers featuring an opengr...

  14. Radio/antenna mounting system for wireless networking under row-crop agriculture conditions

    Science.gov (United States)

    Interest in and deployment of wireless monitoring systems is increasing in many diverse environments, including row-crop agricultural fields. While many studies have been undertaken to evaluate various aspects of wireless monitoring and networking, such as electronic hardware components, data-colle...

  15. Assessment of coronary arteries in infants by 64-detector-row multislice spiral computed tomography

    International Nuclear Information System (INIS)

    Tahara, Masahiro; Waki, Chiaki; Komatsu, Hiroaki; Hayashi, Tomohiro; Sato, Tomoyasu

    2008-01-01

    Heart rate is one of the most important factors for optimal visualization of cardiac CT. We investigated the relation between heart rate and visibility of the coronary arteries with 64-detector row multislice spiral computed tomography (MSCT). Three simulated coronary artery stenosis models (3, 4, and 5 mm) were attached to a moving heart phantom and scanned using 64-detector row MSCT. The heart rate of the phantom was varied between 60 and 150 beats per minutes (bpm). The visibility of simulated coronary arteries was assessed in comparison between cardiac half reconstruction (CHR) and multi-sector reconstruction (MSR). Then contrast-enhanced 64-detector row MSCT was performed in 16 patients under 3 years of age with congenital heart disease and Kawasaki disease without heart rate control. The visibility of coronary artery segments was graded on a three-point scale. The simulated coronary artery patency was detected in the moving phantom at maximum heart rate (150 bpm) with MSR. Minimum lumen diameter was 0.75 mm. Electrocardiogram (ECG)-gated cardiac CT was performed in 9 patients, and non-ECG-gated cardiac CT was performed in 7 patients. The origin and proximal course of coronary arteries in all 9 patients with ECG-gated acquisition were visually evaluated. 64-detector row MSCT with ECG-gated acquisition is able to visualize the origin and proximal course of coronary arteries in infants under 3 years of age. (author)

  16. Estimation of the energy loss at the blades in rowing: common assumptions revisited

    NARCIS (Netherlands)

    Hofmijster, M.J.; de Koning, J.J.; van Soest, A.J.

    2010-01-01

    In rowing, power is inevitably lost as kinetic energy is imparted to the water during push-off with the blades. Power loss is estimated from reconstructed blade kinetics and kinematics. Traditionally, it is assumed that the oar is completely rigid and that force acts strictly perpendicular to the

  17. Influence of intra-row spacing and mulching on weed growth and ...

    African Journals Online (AJOL)

    Two field experiments were conducted during 2000/2001 and 2001/2002 dry seasons under irrigation at Kwalkwalawa Research Fadama Farm of Usmanu Danfodiyo University, Sokoto to investigate the response of weed growth and bulb yield of garlic to intra-row spacing and mulching. The treatments consisted of three ...

  18. Soil quality parameters for row-crop and grazed pasture systems with agroforestry buffers

    Science.gov (United States)

    Incorporation of trees and establishment of buffers are practices that can improve soil quality. Soil enzyme activities and water stable aggregates are sensitive indices for assessing soil quality by detecting early changes in soil management. However, studies comparing grazed pasture and row crop...

  19. Effects of acoustic feedback training in elite-standard Para-Rowing.

    Science.gov (United States)

    Schaffert, Nina; Mattes, Klaus

    2015-01-01

    Assessment and feedback devices have been regularly used in technique training in high-performance sports. Biomechanical analysis is mainly visually based and so can exclude athletes with visual impairments. The aim of this study was to examine the effects of auditory feedback on mean boat speed during on-water training of visually impaired athletes. The German National Para-Rowing team (six athletes, mean ± s, age 34.8 ± 10.6 years, body mass 76.5 ± 13.5 kg, stature 179.3 ± 8.6 cm) participated in the study. Kinematics included boat acceleration and distance travelled, collected with Sofirow at two intensities of training. The boat acceleration-time traces were converted online into acoustic feedback and presented via speakers during rowing (sections with and without alternately). Repeated-measures within-participant factorial ANOVA showed greater boat speed with acoustic feedback than baseline (0.08 ± 0.01 m·s(-1)). The time structure of rowing cycles was improved (extended time of positive acceleration). Questioning of athletes showed acoustic feedback to be a supportive training aid as it provided important functional information about the boat motion independent of vision. It gave access for visually impaired athletes to biomechanical analysis via auditory information. The concept for adaptive athletes has been successfully integrated into the preparation for the Para-Rowing World Championships and Paralympics.

  20. The effect of plant density with different row spacing on quality of the ...

    African Journals Online (AJOL)

    This research was aimed to assess the influence of density with different row spacing on sunflower crop in two different locations in southern Italy. The experiment was laid out in a randomized block design with four replicates. It involved the comparison of sunflower grown in the field on 25 m2 (5 x 5 m) plots at three plant ...

  1. Current status of multi-detector row helical CT in imaging of adult ...

    African Journals Online (AJOL)

    Current status of multi-detector row helical CT in imaging of adult acquired pancreatic diseases and assessing surgical neoplastic resectability. ... The presence of inflammation, masses, and vascular invasion was evaluated and interpreted images were obtained during each phase. Results were compared with surgery, ...

  2. Influence of intra-row spacing and mulching on weed growth and ...

    African Journals Online (AJOL)

    hope&shola

    2006-02-02

    Feb 2, 2006 ... Two field experiments were conducted during 2000/2001 and 2001/2002 dry seasons under irrigation at. Kwalkwalawa Research Fadama Farm of Usmanu Danfodiyo University, Sokoto to investigate the response of weed growth and bulb yield of garlic to intra-row spacing and mulching. The treatments.

  3. Utility of 64-row MDCT in assessment of neonates with congenital EA and distal TEF

    Directory of Open Access Journals (Sweden)

    Hosam El-Deen Galal Mohamed El-Malah

    2015-12-01

    Conclusion: Preoperative MDCT scan with MPVR, 3D TL-VR of 64-row MDCT which is a noninvasive technique could provide more accurate information about the assessment of the origin of the fistula, the distal esophageal pouches and inter-pouch distance in neonates with EA and distal TEF.

  4. Personalikonsultant Kai Kell : ROWE-metoodika loob paindlikkuse / Kai Kell ; interv. Tiina Saar

    Index Scriptorium Estoniae

    Kell, Kai

    2008-01-01

    HR lighthouse OÜ consulting vanemkonsultant tutvustab ROWE (Results only work environment) metoodikat, mis tugineb põhimõttele, et tööd saab hinnata ainult töötulemuste järgi, ning selle rakendamise eeliseid ja puudusi ettevõtetes

  5. Generalized canonical correlation analysis of matrices with missing rows : A simulation study

    NARCIS (Netherlands)

    van de Velden, Michel; Bijmolt, Tammo H. A.

    A method is presented for generalized canonical correlation analysis of two or more matrices with missing rows. The method is a combination of Carroll's (1968) method and the missing data approach of the OVERALS technique (Van der Burg, 1988). In a simulation study we assess the performance of the

  6. Registration of ‘Kardia’, a Two-Rowed Spring Food Barley

    Science.gov (United States)

    ‘Kardia’ (Reg. No. XXXX, XXXX), a two-rowed spring food barley (Hordeum vulgare L.) developed by the USDA-ARS, Aberdeen, ID, in cooperation with the University of Idaho Agricultural Experiment Station, was released in 2015. Kardia is derived from the cross of ‘03AH3054 / 98Ab12019’ and was advanced...

  7. Effects of Frustration on the Response Rate of Skid Row Alcoholics on a Performance Task

    Science.gov (United States)

    Scorzelli, James F.; Reinke-Scorzelli, Mary

    1976-01-01

    Determines the changes that may occur in the response rates of 14 skid row alcoholics on a performance task after the introduction of a frustration operation. Results suggest a possible relationship between low frustration tolerance and the method by which these individuals tend to motivate themselves. (Author)

  8. Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Scheffel, Hans; Pfammatter, Thomas; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Wildi, Stefan [University Hospital Zurich, Department of Visceral and Transplant Surgery, Zurich (Switzerland); Bauerfeind, Peter [University Hospital Zurich, Division of Gastroenterology, Zurich (Switzerland)

    2007-06-15

    This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding. (orig.)

  9. Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT

    International Nuclear Information System (INIS)

    Scheffel, Hans; Pfammatter, Thomas; Marincek, Borut; Alkadhi, Hatem; Wildi, Stefan; Bauerfeind, Peter

    2007-01-01

    This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding. (orig.)

  10. Effect of plant and row spacing on the yield and oil contents of castor ...

    African Journals Online (AJOL)

    Castor (Ricinus communis L.) is an industrial non edible oilseed adapted to drier areas. An experiment was conducted in the Central Rift Valley of Ethiopia to determine optimum plant population of castor variety Hiruy. Four plant (50, 60, 70 and 80 cm) and four row spacing (60,80,100 and 120 cm) were arranged in factorial ...

  11. CASTOR BEAN AND SUNFLOWER INTERCROPPING SYSTEMS IN ROW ARRANGEMENT: BIOLOGICAL EFFICIENCY

    Directory of Open Access Journals (Sweden)

    Ciro de Miranda Pinto

    2012-07-01

    Full Text Available An experiment field was carried in the agricultural seasons 2008, 2009 and 2010, with aim of studying the response of castorbean (Ricinus communis L. intercropping with sunflower (Helianthus annus L. in row arrangement in the dryland farming conditions. In addition, it was evaluated the biological efficiency of plants in intercropping systems.The design used in the experiment was randomized block with seven treatement and four replications. The treatments were represented by rows of castor oil (Ma and sunflower (Gi listed below: 1Ma:1Gi; 1Ma:2Gi; 1Ma:3Gi; 2Ma:2Gi; 2Ma:3Gi; castor and sunflower in the monoculture. The efficiency of intercropping was measured by LER, ATER, LEC, average between LER and ATER, SPI and CoR. The grain yield of castor bean and sunflower were reduced in intercropped row arrangements. The row arrangement 1Ma:2Gi showed the smallest reduction of average productivity of castor beans and sunflower in the evaluation period of the experiment. The castor bean was the dominant crop in relation to sunflower.

  12. Effect of inter-row spacing and plant stand per hill on the yield of ...

    African Journals Online (AJOL)

    Yield was used to determined the best inter-row spacing and plant stand per bill ... high yieldlng cowpea Vigna unguicuJata lines at Serere Agricultural and Animal P.roduction .... constitute a rich source of adaptation to local conditions.

  13. A hand-held row-column addressed CMUT probe with integrated electronics for volumetric imaging

    DEFF Research Database (Denmark)

    Engholm, Mathias; Christiansen, Thomas Lehrmann; Beers, Christopher

    2015-01-01

    A 3 MHz, λ / 2-pitch 62+62 channel row-column addressed 2-D CMUT array designed to be mounted in a probe handle and connected to a commercial BK Medical scanner for real-time volumetric imaging is presented. It is mounted and wire-bonded on a flexible PCB, which is connected to two rigid PCBs...

  14. Multi-detector row computed tomography angiography of peripheral arterial disease

    International Nuclear Information System (INIS)

    Kock, Marc C.J.M.; Dijkshoorn, Marcel L.; Pattynama, Peter M.T.; Myriam Hunink, M.G.

    2007-01-01

    With the introduction of multi-detector row computed tomography (MDCT), scan speed and image quality has improved considerably. Since the longitudinal coverage is no longer a limitation, multi-detector row computed tomography angiography (MDCTA) is increasingly used to depict the peripheral arterial runoff. Hence, it is important to know the advantages and limitations of this new non-invasive alternative for the reference test, digital subtraction angiography. Optimization of the acquisition parameters and the contrast delivery is important to achieve a reliable enhancement of the entire arterial runoff in patients with peripheral arterial disease (PAD) using fast CT scanners. The purpose of this review is to discuss the different scanning and injection protocols using 4-, 16-, and 64-detector row CT scanners, to propose effective methods to evaluate and to present large data sets, to discuss its clinical value and major limitations, and to review the literature on the validity, reliability, and cost-effectiveness of multi-detector row CT in the evaluation of PAD. (orig.)

  15. Using Google SketchUp to simulate tree row azimuth effects on alley shading

    Science.gov (United States)

    Effect of row azimuth on alley crop illumination is difficult to determine empirically. Our objective was to determine if Google SketchUp (Trimble Inc., Sunnyvale, CA) could be used to simulate effect of azimuth orientation on illumination of loblolly pine (Pinus taeda L.) alleys. Simulations were...

  16. Re: Penetration Behavior of Opposed Rows of Staggered Secondary Air Jets Depending on Jet Penetration Coefficient and Momentum Flux Ratio

    Science.gov (United States)

    Holdeman, James D.

    2016-01-01

    The purpose of this article is to explain why the extension of the previously published C = (S/Ho)sqrt(J) scaling for opposed rows of staggered jets wasn't directly successful in the study by Choi et al. (2016). It is not surprising that staggered jets from opposite sides do not pass each other at the expected C value, because Ho/D and sqrt(J) are much larger than the maximum in previous studies. These, and large x/D's, tend to suggest development of 2-dimensional flow. Although there are distinct optima for opposed rows of in-line jets, single-side injection, and opposed rows of staggered jets based on C, opposed rows of staggered jets provide as good or better mixing performance, at any C value, than opposed rows of in-line jets or jets from single-side injection.

  17. The detectability of the origin of the inferior phrenic artery by paging method on multidetector-row CT angiography

    International Nuclear Information System (INIS)

    Terayama, Koshi

    2005-01-01

    We evaluated the ability to detect the origin of the inferior phrenic artery (IPA) by paging method on multidetector-row computed tomography (CT) angiography. In 104 patients who underwent multidetector-row CT, detectability of the origin of the IPA was assessed. In addition, in 30 patients in whom arteriographic study was performed, the IPA findings on multidetector-row CT were compared with those on arteriography. In 100 patients (96%) the origin of the right IPA was demonstrated with multidetector-row CT and in 93 patients (89%) the origin of the left IPA was demonstrated. CT angiographic findings concurred with arteriographic findings in all 30 patients (100%) who underwent arteriographic study. In conclusion, paging method on multidetector-row CT angiography provides valuable anatomical information regarding IPA. (author)

  18. Effect of beta-alanine, with and without sodium bicarbonate, on 2000-m rowing performance.

    Science.gov (United States)

    Hobson, Ruth M; Harris, Roger C; Martin, Dan; Smith, Perry; Macklin, Ben; Gualano, Bruno; Sale, Craig

    2013-10-01

    To examine the effect of beta-alanine only and beta-alanine with sodium bicarbonate supplementation on 2,000-m rowing performance. Twenty well-trained rowers (age 23 ± 4 y; height 1.85 ± 0.08 m; body mass 82.5 ± 8.9 kg) were assigned to either a placebo or beta-alanine (6.4 g · d(-1) for 4 weeks) group. A 2,000-m rowing time trial (TT) was performed before supplementation (Baseline) and after 28 and 30 days of supplementation. The post supplementation trials involved supplementation with either maltodextrin or sodium bicarbonate in a double-blind, crossover design, creating four study conditions (placebo with maltodextrin; placebo with sodium bicarbonate; beta-alanine with maltodextrin; beta-alanine with sodium bicarbonate). Blood lactate, pH, bicarbonate, and base excess were measured pre-TT, immediately post-TT and at TT+5 min. Performance data were analyzed using magnitude based inferences. Beta-alanine supplementation was very likely to be beneficial to 2,000-m rowing performance (6.4 ± 8.1 s effect compared with placebo), with the effect of sodium bicarbonate having a likely benefit (3.2 ± 8.8 s). There was a small (1.1 ± 5.6 s) but possibly beneficial additional effect when combining chronic beta-alanine supplementation with acute sodium bicarbonate supplementation compared with chronic beta-alanine supplementation alone. Sodium bicarbonate ingestion led to increases in plasma pH, base excess, bicarbonate, and lactate concentrations. Both chronic beta-alanine and acute sodium bicarbonate supplementation alone had positive effects on 2,000-m rowing performance. The addition of acute sodium bicarbonate to chronic beta-alanine supplementation may further enhance rowing performance.

  19. Prevalence and Characteristics of Myocardial Bridging in Multidetector-Row Computed Tomography Coronary Angiography

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Martin Lopez, Elba; Capunay, Carlos; Deviggiano, Alejandro; Vallejos, Javier; Carrascosa, Jorge

    2009-01-01

    Background: Myocardial bridging (MB) are congenital defects of the coronary arteries in which a segment of an epicardial artery lies in the myocardium for part of its course. The current gold standard for diagnosing MB is coronary angiography; however other invasive techniques are also useful. Myocardial bridging can also be visualized with the use of novel non-invasive imaging techniques such as multidetector-row computed tomography coronary angiography (MDCT-CA). Objectives: To assess the prevalence and characteristics of myocardial bridging in patients undergoing multidetector-row computed tomography coronary angiography (MDCT-CA). Material and Methods: A total of 452 consecutive patients were evaluated with 16-row and 64-row MDCT-CA due to the presence of abnormal findings in myocardial perfusion image tests, symptoms suggestive of coronary artery disease, and in asymptomatic patients with a family history of coronary artery disease. The presence of MB, their location and characteristics were analyzed. Myocardial bridging were classified as complete and incomplete bridges with respect to continuity of the myocardium over the tunneled segment of the artery involved. Quantitative measurements of vessel diameter during systole and diastole were evaluated. Results: The prevalence of MB was 35.18%; 88 were complete and 71 incomplete. Among complete MB, 6 affected both systole and diastole, 27 presented only systolic compression and 55 showed no compression. Incomplete MB showed absence of arterial compression. Conclusions: Multidetector-row computed tomography coronary angiography detected a higher prevalence of MB in the study population and allowed to classify them and to assess their functional aspects throughout the cardiac cycle. (authors) [es

  20. Design, Fabrication and Performance Evaluation of an Inter-Row Cultivator for Sugarcane Fields

    Directory of Open Access Journals (Sweden)

    Yuttana Khaehanchanpong

    2017-09-01

    Full Text Available The aims of this research were to design and fabricate an inter-row cultivator for mounting on a medium-sized tractor (25.3 or 37.3 kW for sugarcane fields, and to assess the performance of the cultivator when harvesting is conducted either by hand or with a sugarcane harvester. Moreover, this study was also designed to assess the performance of the cultivator in mixing sugarcane residues in the field. The inter-row cultivator has a working width of 80 cm, a rotor shaft speed of 500 rpm, and a total weight of 518 kg. The cultivator comprises 18 European C-type blades attached to three disk holder flanges arranged in a spiral formation. Two notch-cutting discs were mounted on the front to cut and press the sugarcane leaves before they were chopped and mixed by the inter-row cultivator. The working performance test was conducted for different thicknesses of trash blankets while using the inter-row cultivator mounted on 25.3 kW- and 37.3 kW-size tractors. The effective field capacity for trash incorporation of the inter-row cultivator was 0.30 ha·h−1 when trash was left through harvesting by hand. On the other hand, effective field capacity was 0.31 ha·h−1 when a sugarcane harvester was used. Moreover, the field efficiency exceeded 90% in all tested fields, with greater soil inversion. The results also showed that the fuel consumption of both tractors was higher when harvesting by hand compared with harvesting using a harvester.

  1. NO INFLUENCE OF HYPOXIA ON COORDINATION BETWEEN RESPIRATORY AND LOCOMOTOR RHYTHMS DURING ROWING AT MODERATE INTENSITY

    Directory of Open Access Journals (Sweden)

    Nicolas Fabre

    2007-12-01

    Full Text Available Besides neuro-mechanical constraints, chemical or metabolic stimuli have also been proposed to interfere with the coordination between respiratory and locomotor rhythms. In the light of the conflicting data observed in the literature, this study aimed to assess whether acute hypoxia modifies the degree of coordination between respiratory and locomotor rhythms during rowing exercises in order to investigate competitive interactions between neuro-mechanical (movement and chemical (hypoxia respiratory drives. Nine male healthy subjects performed one submaximal 6-min rowing exercise on a rowing ergometer in both normoxia (altitude: 304 m and acute hypoxia (altitude: 2877 m. The exercise intensity was about 40 % and 35 % (for normoxia and hypoxia conditions, respectively of the individual maximal power output measured during an incremental rowing test to volitional exhaustion carried out in normoxia. Metabolic rate and minute ventilation were continuously collected throughout exercise. Locomotor movement and breathing rhythms were continuously recorded and synchronized cycle-by-cycle. The degree of coordination was expressed as a percentage of breaths starting during the same phase of the locomotor cycle. For a same and a constant metabolic rate, acute hypoxia did not influence significantly the degree of coordination (mean ± SEM, normoxia: 20.0 ± 6.2 %, hypoxia: 21.3 ± 11.1 %, p > 0.05 while ventilation and breathing frequency were significantly greater in hypoxia. Our results may suggest that during rowing exercise at a moderate metabolic load, neuro-mechanical locomotion-linked respiratory stimuli appear "stronger" than peripheral chemoreceptors- linked respiratory stimuli induced by hypoxia, in the context of our study

  2. Load response and gap formation in a single-row cruciate suture rotator cuff repair.

    Science.gov (United States)

    Huntington, Lachlan; Richardson, Martin; Sobol, Tony; Caldow, Jonathon; Ackland, David C

    2017-06-01

    Double-row rotator cuff tendon repair techniques may provide superior contact area and strength compared with single-row repairs, but are associated with higher material expenses and prolonged operating time. The purpose of this study was to evaluate gap formation, ultimate tensile strength and stiffness of a single-row cruciate suture rotator cuff repair construct, and to compare these results with those of the Mason-Allen and SutureBridge repair constructs. Infraspinatus tendons from 24 spring lamb shoulders were harvested and allocated to cruciate suture, Mason-Allen and SutureBridge repair groups. Specimens were loaded cyclically between 10 and 62 N for 200 cycles, and gap formation simultaneously measured using a high-speed digital camera. Specimens were then loaded in uniaxial tension to failure, and construct stiffness and repair strength were evaluated. Gap formation in the cruciate suture repair was significantly lower than that of the Mason-Allen repair (mean difference = 0.6 mm, P = 0.009) and no different from that of the SutureBridge repair (P > 0.05). Both the cruciate suture repair (mean difference = 15.7 N/mm, P = 0.002) and SutureBridge repair (mean difference = 15.8 N/mm, P = 0.034) were significantly stiffer than that of the Mason-Allen repair; however, no significant differences in ultimate tensile strength between repair groups were discerned (P > 0.05). The cruciate suture repair construct, which may represent a simple and cost-effective alternative to double-row and double-row equivalent rotator cuff repairs, has comparable biomechanical strength and integrity with that of the SutureBridge repair, and may result in improved construct longevity and tendon healing compared with the Mason-Allen repair. © 2017 Royal Australasian College of Surgeons.

  3. Suture spanning augmentation of single-row rotator cuff repair: a biomechanical analysis.

    Science.gov (United States)

    Early, Nicholas A; Elias, John J; Lippitt, Steven B; Filipkowski, Danielle E; Pedowitz, Robert A; Ciccone, William J

    2017-02-01

    This in vitro study evaluated the biomechanical benefit of adding spanning sutures to single-row rotator cuff repair. Mechanical testing was performed to evaluate 9 pairs of cadaveric shoulders with complete rotator cuff repairs, with a single-row technique used on one side and the suture spanning technique on the other. The spanning technique included sutures from 2 lateral anchors securing tendon near the musculotendinous junction, spanning the same anchor placement from single-row repair. The supraspinatus muscle was loaded to 100 N at 0.25 Hz for 100 cycles, followed by a ramp to failure. Markers and a video tracking system measured anterior and posterior gap formation across the repair at 25-cycle intervals. The force at which the stiffness decreased by 50% and 75% was determined. Data were compared using paired t-tests. One single-row repair failed at row repairs than for the suture spanning technique. The difference was statistically significant at all cycles for the posterior gap formation (P ≤ .02). The trends were not significant for the anterior gap (P ≥ .13). The loads at which the stiffness decreased by 50% and 75% did not differ significantly between the 2 types of repair (P ≥ .10). The suture spanning technique primarily improved posterior gap formation. Decreased posterior gap formation could reduce failure rates for rotator cuff repair. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Developmental constraints revealed by co-variation within and among molar rows in two murine rodents.

    Science.gov (United States)

    Renaud, Sabrina; Pantalacci, Sophie; Quéré, Jean-Pierre; Laudet, Vincent; Auffray, Jean-Christophe

    2009-01-01

    Morphological integration corresponds to interdependency between characters that can arise from several causes. Proximal causes of integration include that different phenotypic features may share common genetic sets and/or interact during their development. Ultimate causes may be the prolonged effect of selection favoring integration of functionally interacting characters, achieved by the molding of these proximal causes. Strong and direct interactions among successive teeth of a molar row are predicted by genetic and developmental evidences. Functional constraints related to occlusion, however, should have selected more strongly for a morphological integration of occluding teeth and a corresponding evolution of the underlying developmental and genetic pathways. To investigate how these predictions match the patterns of phenotypic integration, we studied the co-variation among the six molars of the murine molar row, focusing on two populations of house mice (Mus musculus domesticus) and wood mice (Apodemus sylvaticus). The size and shape of the three upper and lower molars were quantified and compared. Our results evidenced similar patterns in both species, size being more integrated than shape among all the teeth, and both size and shape co-varying strongly between adjacent teeth, but also between occluding teeth. Strong co-variation within each molar row is in agreement with developmental models showing a cascade influence of the first molar on the subsequent molars. In contrast, the strong co-variation between molars of the occluding tooth rows confirms that functional constraints molded patterns of integration and probably the underlying developmental pathways despite the low level of direct developmental interactions occurring among molar rows. These patterns of co-variation are furthermore conserved between the house mouse and the wood mouse that diverged >10 Ma, suggesting that they may constitute long-running constraints to the diversification of the murine

  5. On the 2-Row Rule for Infectious Disease Transmission on Aircraft.

    Science.gov (United States)

    Hertzberg, Vicki Stover; Weiss, Howard

    With over two billion airline passengers annually, in-flight transmission of infectious diseases is an important global health concern. Many instances of in-flight transmission have been documented, but the relative influence of the many factors (see below) affecting in-flight transmission has not been quantified. Long-standing guidance by public health agencies is that the primary transmission risk associated with air travel for most respiratory infectious diseases is associated with sitting within two rows of an infectious passenger. The effect of proximity may be one of these factors. The aim of this study was to determine the risk of infection within and beyond the 2-row rule given by public health guidance. We searched the literature for reports of in-flight transmission of infection which included seat maps indicating where the infectious and infected passengers were seated. There is a ∼ 6% risk to passengers seated within the 2-rows of infected individual(s) and there is ∼ 2% risk to passengers seated beyond 2-rows from the infectious individual. Contact tracing limited to passengers within 2-rows of the infectious individual(s) could fail to detect other cases of infections. This has important consequences for assessing the spread of infectious diseases. Infection at a distance from the index case indicates other factors, such as airflow, movement of passenger/crew members, fomites and contacts between passengers in the departure gate before boarding, or after deplaning, are involved. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Multilayer Photonic Crystal for Spectral Narrowing of Emission

    Directory of Open Access Journals (Sweden)

    Zhanfang LIU

    2017-08-01

    Full Text Available Multilayer colloidal crystal has been prepared by the layer-by-layer deposition of silica microspheres on a glass slide. Each layer is a slab consisting of a fcc close-packed colloidal arrays. By properly choosing the sizes of spheres, the whole spectral feature of multilayer colloidal crystal can be tuned. Here, we engineered a multilayer superlattice structure with an effective passband between two stop bands. This gives a strong narrowing effect on emission spectrum. With the stop bands at the shortwave and longwave edges of emission spectrum, the passband in the central wavelength region can be regarded as a strong decrease of suppression effect and enhancement of a narrow wavelength region of emission. The spectral narrowing modification effect of suitably engineered colloidal crystals shows up their importance in potential application as optical filters and lasing devices.DOI: http://dx.doi.org/10.5755/j01.ms.23.3.16320

  7. CT demonstration of pharyngeal narrowing in adult obstructive sleep apnea

    International Nuclear Information System (INIS)

    Bohlman, M.E.; Haponik, E.F.; Smith, P.L.; Allen, R.P.; Bleecker, E.R.; Goldman, S.M.

    1983-01-01

    Sleep apnea is a major cause of daytime hypersomnolence. Among the proposed etiologies, focal obstruction of the airways at the level of the pharynx has been suggested but not proven. Using computed tomography, the cross-sectional area of the airway can be readily assessed. Thirty-three adults with clinically proven sleep apnea and 12 normal adults underwent systematic computed tomography of the neck. Significant airway narrowing was demonstrated in all the patients with obstructive sleep apnea, whereas no such narrowing was seen in the controls. In 11, the narrowing was at a single level, whereas in 22 patients two or more levels were affected. This study has shown that a structurally abnormal airway may serve as an anatomic substrate for the development of sleep apnea. On the basis of this evidence, uvulopalatopharyngoplasty has been performed in two patients with relief of symptoms in one

  8. Pressure Fluctuation Characteristics of Narrow Gauge Train Running Through Tunnel

    Science.gov (United States)

    Suzuki, Masahiro; Sakuma, Yutaka

    Pressure fluctuations on the sides of narrow (1067 mm) gauge trains running in tunnels are measured for the first time to investigate the aerodynamic force acting on the trains. The present measurements are compared with earlier measurements obtained with the Shinkansen trains. The results are as follows: (1) The aerodynamic force, which stems from pressure fluctuations on the sides of cars, puts the energy into the vibration of the car body running through a tunnel. (2) While the pressure fluctuations appear only on one of the two sides of the trains running in double-track tunnels, the fluctuations in opposite phase on both sides in single-track tunnels. (3) The on-track test data of the narrow gauge trains show the same tendency as those of the Shinkansen trains, although it is suggested that the pressure fluctuations develop faster along the narrow gauge trains than the Shinkansen trains.

  9. MRI of surgically created pulmonary artery narrowing in the dog

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, R.J.; Rocchini, A.P.; Bove, E.L.; Chenevert, T.L.; Gubin, B. (Michigan Univ., Ann Arbor (USA). Dept. of Radiology)

    1989-11-01

    Narrowing of the pulmonary arteries was created surgically in twelve dogs. In six of the dogs the narrowing was central (main pulmonary artery), and in the remaining six the narrowing was located peripherally at the hilar level of the right pulmonary artery beyond the pericardial reflection. MRI and angiography were performed in all dogs. MRI clearly delineated the site of the pulmonary band and the caliber of the pulmonary artery at the site of the band in all dogs (N=6). MRI was not able to visualize any of the stenosis of the right pulmonary arteries at the hila, beyond the pericardial reflection. In addition, optimal imaging planes to depict each segment of the central pulmonary arteries were determined. The capability to image in oblique planes is essential in evaluating the morphology of the central pulmonary arteries. (orig.).

  10. MRI of surgically created pulmonary artery narrowing in the dog

    International Nuclear Information System (INIS)

    Hernandez, R.J.; Rocchini, A.P.; Bove, E.L.; Chenevert, T.L.; Gubin, B.

    1989-01-01

    Narrowing of the pulmonary arteries was created surgically in twelve dogs. In six of the dogs the narrowing was central (main pulmonary artery), and in the remaining six the narrowing was located peripherally at the hilar level of the right pulmonary artery beyond the pericardial reflection. MRI and angiography were performed in all dogs. MRI clearly delineated the site of the pulmonary band and the caliber of the pulmonary artery at the site of the band in all dogs (N=6). MRI was not able to visualize any of the stenosis of the right pulmonary arteries at the hila, beyond the pericardial reflection. In addition, optimal imaging planes to depict each segment of the central pulmonary arteries were determined. The capability to image in oblique planes is essential in evaluating the morphology of the central pulmonary arteries. (orig.)

  11. Fabrication et applications des reseaux de Bragg ultra-longs

    Science.gov (United States)

    Gagne, Mathieu

    quality ultra long fiber Bragg gratings. High quality theory matching ultra long fiber Bragg gratings up to 1 meter long are obtained for the first time. The possibility of fabricating high quality ultra long fiber Bragg grating of more than 10 cm (approximately the maximal phase mask length) opens a variety of new applications otherwise impossible with short fiber Bragg grating technology. Ultra long fiber Bragg gratings have unique characteristics such as high reflectivity, high dispersion and ultra narrow bandwidth. Those characteristics can be used to do advanced signal processing, non linear propagation experiments, distributed feedback fiber lasers and dispersion compensator for telecommunication or optical tomography. The second objective of this project is to use these ultra-long fiber Bragg gratings as an optical cavity for fiber lasers. Alot of research in the past years have been concentrated on those lasers, particularly on distributed feedback fiber lasers where the gratings spans all the gain media. A new random fiber laser configuration is presented. It is based on passive or active insertion of phase shifts along the Bragg grating to obtained a phenomenon called light localization which is the optical equivalent of Anderson localization. This complex wave phenomenon has the unique property to mimic the reflection of a uniform photonic crystal with the random diffusion of light among the elements of a random media. Being commonly obtained in fine powders which must respect a certain set of rules, the realization of 1D structures is vastly simplified in optical fibers. Two random fiber laser schemes based on light localization, one using erbium dopant and the other one Raman scattering, are demonstrated for the first time and compared to traditional distributed feedback fiber lasers.

  12. Narrow linewidth diode laser modules for quantum optical sensor applications in the field and in space

    Science.gov (United States)

    Wicht, A.; Bawamia, A.; Krüger, M.; Kürbis, Ch.; Schiemangk, M.; Smol, R.; Peters, A.; Tränkle, G.

    2017-02-01

    We present the status of our efforts to develop very compact and robust diode laser modules specifically suited for quantum optics experiments in the field and in space. The paper describes why hybrid micro-integration and GaAs-diode laser technology is best suited to meet the needs of such applications. The electro-optical performance achieved with hybrid micro-integrated, medium linewidth, high power distributed-feedback master-oscillator-power-amplifier modules and with medium power, narrow linewidth extended cavity diode lasers emitting at 767 nm and 780 nm are briefly described and the status of space relevant stress tests and space heritage is summarized. We also describe the performance of an ECDL operating at 1070 nm. Further, a novel and versatile technology platform is introduced that allows for integration of any type of laser system or electro-optical module that can be constructed from two GaAs chips. This facilitates, for the first time, hybrid micro-integration, e.g. of extended cavity diode laser master-oscillator-poweramplifier modules, of dual-stage optical amplifiers, or of lasers with integrated, chip-based phase modulator. As an example we describe the implementation of an ECDL-MOPA designed for experiments on ultra-cold rubidium and potassium atoms on board a sounding rocket and give basic performance parameters.

  13. Acceptor-modulated optical enhancements and band-gap narrowing in ZnO thin films

    Science.gov (United States)

    Hassan, Ali; Jin, Yuhua; Irfan, Muhammad; Jiang, Yijian

    2018-03-01

    Fermi-Dirac distribution for doped semiconductors and Burstein-Moss effect have been correlated first time to figure out the conductivity type of ZnO. Hall Effect in the Van der Pauw configuration has been applied to reconcile our theoretical estimations which evince our assumption. Band-gap narrowing has been found in all p-type samples, whereas blue Burstein-Moss shift has been recorded in the n-type films. Atomic Force Microscopic (AFM) analysis shows that both p-type and n-type films have almost same granular-like structure with minor change in average grain size (˜ 6 nm to 10 nm) and surface roughness rms value 3 nm for thickness ˜315 nm which points that grain size and surface roughness did not play any significant role in order to modulate the conductivity type of ZnO. X-ray diffraction (XRD), Energy Dispersive X-ray Spectroscopy (EDS) and X-ray Photoelectron Spectroscopy (XPS) have been employed to perform the structural, chemical and elemental analysis. Hexagonal wurtzite structure has been observed in all samples. The introduction of nitrogen reduces the crystallinity of host lattice. 97% transmittance in the visible range with 1.4 × 107 Ω-1cm-1 optical conductivity have been detected. High absorption value in the ultra-violet (UV) region reveals that NZOs thin films can be used to fabricate next-generation high-performance UV detectors.

  14. Acceptor-modulated optical enhancements and band-gap narrowing in ZnO thin films

    Directory of Open Access Journals (Sweden)

    Ali Hassan

    2018-03-01

    Full Text Available Fermi-Dirac distribution for doped semiconductors and Burstein-Moss effect have been correlated first time to figure out the conductivity type of ZnO. Hall Effect in the Van der Pauw configuration has been applied to reconcile our theoretical estimations which evince our assumption. Band-gap narrowing has been found in all p-type samples, whereas blue Burstein-Moss shift has been recorded in the n-type films. Atomic Force Microscopic (AFM analysis shows that both p-type and n-type films have almost same granular-like structure with minor change in average grain size (∼ 6 nm to 10 nm and surface roughness rms value 3 nm for thickness ∼315 nm which points that grain size and surface roughness did not play any significant role in order to modulate the conductivity type of ZnO. X-ray diffraction (XRD, Energy Dispersive X-ray Spectroscopy (EDS and X-ray Photoelectron Spectroscopy (XPS have been employed to perform the structural, chemical and elemental analysis. Hexagonal wurtzite structure has been observed in all samples. The introduction of nitrogen reduces the crystallinity of host lattice. 97% transmittance in the visible range with 1.4 × 107 Ω-1cm-1 optical conductivity have been detected. High absorption value in the ultra-violet (UV region reveals that NZOs thin films can be used to fabricate next-generation high-performance UV detectors.

  15. Narrow-band tunable terahertz emission from ferrimagnetic Mn{sub 3-x}Ga thin films

    Energy Technology Data Exchange (ETDEWEB)

    Awari, N. [Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstr. 400, 01328 Dresden (Germany); University of Groningen, 9747 AG Groningen (Netherlands); Kovalev, S., E-mail: s.kovalev@hzdr.de, E-mail: c.fowley@hzdr.de, E-mail: rodek@tcd.ie; Fowley, C., E-mail: s.kovalev@hzdr.de, E-mail: c.fowley@hzdr.de, E-mail: rodek@tcd.ie; Green, B.; Yildirim, O.; Lindner, J.; Fassbender, J.; Deac, A. M.; Gensch, M. [Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstr. 400, 01328 Dresden (Germany); Rode, K., E-mail: s.kovalev@hzdr.de, E-mail: c.fowley@hzdr.de, E-mail: rodek@tcd.ie; Lau, Y.-C.; Betto, D.; Thiyagarajah, N.; Coey, J. M. D. [CRANN, AMBER and School of Physics, Trinity College Dublin, Dublin 2 (Ireland); Gallardo, R. A. [Departamento de Física, Universidad Técnica Federico Santa María, Avenida España 1680, 2390123 Valparíso (Chile)

    2016-07-18

    Narrow-band terahertz emission from coherently excited spin precession in metallic ferrimagnetic Mn{sub 3-x}Ga Heusler alloy nanofilms has been observed. The efficiency of the emission, per nanometer film thickness, is comparable or higher than that of classical laser-driven terahertz sources based on optical rectification. The center frequency of the emission from the films can be tuned precisely via the film composition in the range of 0.20–0.35 THz, making this type of metallic film a candidate for efficient on-chip terahertz emitters. Terahertz emission spectroscopy is furthermore shown to be a sensitive probe of magnetic properties of ultra-thin films.

  16. Biomechanical comparison of four double-row speed-bridging rotator cuff repair techniques with or without medial or lateral row enhancement.

    Science.gov (United States)

    Pauly, Stephan; Fiebig, David; Kieser, Bettina; Albrecht, Bjoern; Schill, Alexander; Scheibel, Markus

    2011-12-01

    Biomechanical comparison of four different Speed-Bridge configurations with or without medial or lateral row reinforcement. Reinforcement of the knotless Speed-Bridge double-row repair technique with additional medial mattress- or lateral single-stitches was hypothesized to improve biomechanical repair stability at time zero. Controlled laboratory study: In 36 porcine fresh-frozen shoulders, the infraspinatus tendons were dissected and shoulders were randomized to four groups: (1) Speed-Bridge technique with single tendon perforation per anchor (STP); (2) Speed-Bridge technique with double tendon perforation per anchor (DTP); (3) Speed-Bridge technique with medial mattress-stitch reinforcement (MMS); (4) Speed-Bridge technique with lateral single-stitch reinforcement (LSS). All repairs were cyclically loaded from 10-60 N up to 10-200 N (20 N stepwise increase) using a material testing device. Forces at 3 and 5 mm gap formation, mode of failure and maximum load to failure were recorded. The MMS-technique with double tendon perforation showed significantly higher ultimate tensile strength (338.9 ± 90.0 N) than DTP (228.3 ± 99.9 N), LSS (188.9 ± 62.5 N) and STP-technique (122.2 ± 33.8 N). Furthermore, the MMS-technique provided increased maximal force resistance until 3 and 5 mm gap formation (3 mm: 77.8 ± 18.6 N; 5 mm: 113.3 ± 36.1 N) compared with LSS, DTP and STP (P row defect by tendon sawing first, then laterally. No anchor pullout occurred. Double tendon perforation per anchor and additional medial mattress stitches significantly enhance biomechanical construct stability at time zero in this ex vivo model when compared with the all-knotless Speed-Bridge rotator cuff repair.

  17. Narrow-width mechanism of a=5 Ξ-state

    International Nuclear Information System (INIS)

    Kumagai-Fuse, I.; Akaishi, Y.

    1995-04-01

    Narrow-width mechanism of ≡ 5 H is discussed by calculating conversion widths to all its possible decay channels. Since the conversion processes have small reaction Q values, the three- and four- body decays are strongly suppressed owing to small phase volumes available. Decay widths to the two-body channels are significantly reduced by the distortion of emitted-particle waves. This mechanism brings about a narrow width of ≡ 5 H. The total width is estimated to be 0.87 MeV, in which the largest contribution comes from the decay into the Λ 4 H * +Λ channel. (author)

  18. Nanofiber Anisotropic Conductive Films (ACF) for Ultra-Fine-Pitch Chip-on-Glass (COG) Interconnections

    Science.gov (United States)

    Lee, Sang-Hoon; Kim, Tae-Wan; Suk, Kyung-Lim; Paik, Kyung-Wook

    2015-11-01

    Nanofiber anisotropic conductive films (ACF) were invented, by adapting nanofiber technology to ACF materials, to overcome the limitations of ultra-fine-pitch interconnection packaging, i.e. shorts and open circuits as a result of the narrow space between bumps and electrodes. For nanofiber ACF, poly(vinylidene fluoride) (PVDF) and poly(butylene succinate) (PBS) polymers were used as nanofiber polymer materials. For PVDF and PBS nanofiber ACF, conductive particles of diameter 3.5 μm were incorporated into nanofibers by electrospinning. In ultra-fine-pitch chip-on-glass assembly, insulation was significantly improved by using nanofiber ACF, because nanofibers inside the ACF suppressed the mobility of conductive particles, preventing them from flowing out during the bonding process. Capture of conductive particles was increased from 31% (conventional ACF) to 65%, and stable electrical properties and reliability were achieved by use of nanofiber ACF.

  19. Repair of lesser tuberosity osteotomy for shoulder arthroplasty: biomechanical evaluation of the Backpack and Dual Row techniques.

    Science.gov (United States)

    Heckman, Daniel S; Hoover, Stephen A; Weinhold, Paul S; Spang, Jeffrey T; Creighton, R Alexander

    2011-04-01

    Subscapularis dysfunction following total shoulder arthroplasty can result in permanent loss of function. The lesser tuberosity osteotomy (LTO) has been proposed as a method which utilizes bone-to-bone healing to improve subscapularis function. This study evaluates the biomechanical properties of two described techniques for LTO repair. We hypothesized that a Dual Row repair would be stronger and demonstrate less cyclic displacement than a Backpack repair. Ten matched pairs of cadaveric humeri were dissected, leaving the subscapularis intact, and a lesser tuberosity osteotomy was performed. Matched shoulders were randomized to either a Backpack repair or a Dual Row repair. Repairs were subjected to cyclic loading to 180 N for 500 cycles, followed by ramp-up loading to ultimate failure. Clinical failure was defined as displacement >5 mm after 500 cycles. Displacement after 500 cycles was significantly greater for the Backpack repair (6.9 mm) than for the Dual Row repair (4.6 mm) (P = .007). Most displacement occurred on the first cycle (Backpack, 4.6 mm; Dual Row, 2.1 mm) (P Row repair (3/10). Ultimate tensile strength was significantly greater for the Dual Row repair (632.3 N) than for the Backpack repair (510.9 N) (P = .01). The Dual Row technique is significantly stronger and demonstrates less cyclic displacement than the Backpack technique. Clinical studies are needed to determine the impact of LTO repair technique on subscapularis function following shoulder arthroplasty. Copyright © 2011. Published by Mosby, Inc.

  20. Transosseous-equivalent rotator cuff repair: a systematic review on the biomechanical importance of tying the medial row.

    Science.gov (United States)

    Mall, Nathan A; Lee, Andrew S; Chahal, Jaskarndip; Van Thiel, Geoffrey S; Romeo, Anthony A; Verma, Nikhil N; Cole, Brian J

    2013-02-01

    Double-row and transosseous-equivalent repair techniques have shown greater strength and improved healing than single-row techniques. The purpose of this study was to determine whether tying of the medial-row sutures provides added stability during biomechanical testing of a transosseous-equivalent rotator cuff repair. We performed a systematic review of studies directly comparing biomechanical differences. Five studies met the inclusion and exclusion criteria. Of the 5 studies, 4 showed improved biomechanical properties with tying the medial-row anchors before bringing the sutures laterally to the lateral-row anchors, whereas the remaining study showed no difference in contact pressure, mean failure load, or gap formation with a standard suture bridge with knots tied at the medial row compared with knotless repairs. The results of this systematic review and quantitative synthesis indicate that the biomechanical factors ultimate load, stiffness, gap formation, and contact area are significantly improved when medial knots are tied as part of a transosseous-equivalent suture bridge construct compared with knotless constructs. Further studies comparing the clinical healing rates and functional outcomes between medial knotted and knotless repair techniques are needed. This review indicates that biomechanical factors are improved when the medial row of a transosseous-equivalent rotator cuff is tied compared with a knotless repair. However, this has not been definitively proven to translate to improved healing rates clinically. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. Evaluation of an autonomous GPS-based system for intra-row weed control by assessing the tilled area

    DEFF Research Database (Denmark)

    Nørremark, M; Griepentrog, H W; Nielsen, J

    2012-01-01

    -1 and at even plant spacing. A double pass, once on each side of the row in opposite directions, provided higher soil disturbance intensity and resulted in tillage of 31–58% of the intra-row area with highest coverage at a speed of 0.32 m s-1. The intra-row weed control effect was predicted to be up......An automatic tillage system for inter- and intra-row weed control based on real-time kinematic GPS navigation and control has been used to address the problem of mechanically removing weeds within rows of precision seeded crops. The system comprised a side-shifting frame with an attached tine...... crop plants. The system evaluation was based on quantification of treated areas for uprooting and burial and the corresponding prediction of weed control efficiencies. A single pass of an 80 mm wide row band provided tillage of 30–49% of the intra-row area, with highest coverage at a speed of 0.32 m s...

  2. The Argument for a Narrow Conception of 'Religious Autonomy'

    DEFF Research Database (Denmark)

    Christoffersen, Lisbet

    2015-01-01

    This article argues for a both horizontal and vertical narrow concept of collective freedom of Religion. The most recent ECtHR judgments as well as the US Supreme Court Hosanna-Tabor case leads theory to establish religious autonomy based on parallel legal roders. Nordic theory has been based...

  3. Predicting soil nitrogen content using narrow-band indices from ...

    African Journals Online (AJOL)

    Optimal fertiliser applications for sustainable forest stand productivity management, whilst protecting the environment, is vital. This study estimated soil nitrogen content using leaf-level narrow-band vegetation indices derived from a hand-held 350–2 500 nm spectroradiometer. Leaf-level spectral data were collected and ...

  4. Nonstationary Narrow-Band Response and First-Passage Probability

    DEFF Research Database (Denmark)

    Krenk, Steen

    1979-01-01

    The notion of a nonstationary narrow-band stochastic process is introduced without reference to a frequency spectrum, and the joint distribution function of two consecutive maxima is approximated by use of an envelope. Based on these definitions the first passage problem is treated as a Markov po...

  5. Free-Molecular Gas Flow in Narrow (Nanoscale) Channel

    Czech Academy of Sciences Publication Activity Database

    Levdansky, V.V.; Roldugin, V.I.; Žďanov, V.M.; Ždímal, Vladimír

    2014-01-01

    Roč. 87, č. 4 (2014), s. 802-814 ISSN 1062-0125 Grant - others:BRFFI(BY) T12P-018; RFBR(RU) 12-08-90009 Institutional support: RVO:67985858 Keywords : narrow channels * free-molecular gas flow * surface diffusion Subject RIV: CF - Physical ; Theoretical Chemistry

  6. Experimental Study on Critical Power in a Hemispherical Narrow Gap

    International Nuclear Information System (INIS)

    Park, Rae-Joon; Ha, Kwang-Soon; Kim, Sang-Baik; Kim, Hee-Dong; Jeong, Ji-Hwan

    2002-01-01

    An experimental study of critical heat flux in gap (CHFG) has been performed to investigate the inherent cooling mechanism in a hemispherical narrow gap. The objectives of the CHFG test are to measure critical power from a critical heat removal rate through the hemispherical narrow gap using distilled water with experimental parameters of system pressure and gap width. The CHFG test results have shown that a countercurrent flow limitation (CCFL) brings about local dryout at the small edge region of the upper part and finally global dryout in a hemispherical narrow gap. Increases in the gap width and pressure lead to an increase in critical power. The measured values of critical power are lower than the predictions made by other empirical CHF correlations applicable to flat plate, annuli, and small spherical gaps. The measured data on critical power in the hemispherical narrow gaps have been correlated using nondimensional parameters with a range of approximately ±20%. The developed correlation has been expanded to apply the spherical geometry using the Siemens/KWU correlation

  7. Career Attainment among Healthcare Executives: Is the Gender Gap Narrowing?

    Science.gov (United States)

    Branin, Joan Julia

    2009-01-01

    Health care occupations are expected to be among the fastest growing professions in the next ten years. With such incredible growth expected in employment and wages, and with women's participation in the industry remaining strong, are women in the health care industry, particularly those in health care administration, experiencing a narrowing of…

  8. Narrow-Band Imaging: Clinical Application in Gastrointestinal Endoscopy

    Directory of Open Access Journals (Sweden)

    Sandra Barbeiro

    2018-03-01

    Full Text Available Narrow-band imaging is an advanced imaging system that applies optic digital methods to enhance endoscopic images and improves visualization of the mucosal surface architecture and microvascular pattern. Narrow-band imaging use has been suggested to be an important adjunctive tool to white-light endoscopy to improve the detection of lesions in the digestive tract. Importantly, it also allows the distinction between benign and malignant lesions, targeting biopsies, prediction of the risk of invasive cancer, delimitation of resection margins, and identification of residual neoplasia in a scar. Thus, in expert hands it is a useful tool that enables the physician to decide on the best treatment (endoscopic or surgical and management. Current evidence suggests that it should be used routinely for patients at increased risk for digestive neoplastic lesions and could become the standard of care in the near future, at least in referral centers. However, adequate training programs to promote the implementation of narrow-band imaging in daily clinical practice are needed. In this review, we summarize the current scientific evidence on the clinical usefulness of narrow-band imaging in the diagnosis and characterization of digestive tract lesions/cancers and describe the available classification systems.

  9. Note: Folded optical system for narrow forward looking probe

    International Nuclear Information System (INIS)

    Hou, Hsuan-Chao; Hah, Dooyoung; Kim, Jeonghwan; Feldman, M.

    2014-01-01

    An optical system is described in which a laser beam makes three passes through a single graded index lens, forming a focus along the optic axis. It has important applications in endoscopic probes, where the forward looking characteristic permits the avoidance of obstacles and the narrow structure makes it minimally invasive

  10. Modeling of air flow through a narrow crack

    International Nuclear Information System (INIS)

    Trojek, T.; Cechak, T.; Moucka, L.; Fronka, A.

    2004-01-01

    Radon transport in dwellings is governed to a significant extent by pressure differences and properties of transport pathways. A model of air flow through narrow cracks was created in order to facilitate prediction of air velocity and air flow. Theoretical calculations, based on numerical solution of a system of differential equations, were compared with measurements carried out on a window crack. (P.A.)

  11. Measurements of Narrow Mg II Associated Absorption Doublets with ...

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... The measurement of the variations of absorption lines over time is a good method to study the physical conditions of absorbers. In this paper, we measure the variations of the line strength of 36 narrow Mg II2796, 2803 associated absorption doublets, which are imprinted on 31 quasar spectra with two ...

  12. Japanese VLBI Network Observations of a Gamma-Ray Narrow ...

    Indian Academy of Sciences (India)

    J. Astrophys. Astr. (2014) 35, 215–218 c Indian Academy of Sciences. Japanese VLBI Network Observations of a Gamma-Ray. Narrow-Line Seyfert 1 Galaxy 1H 0323+342. Kiyoaki Wajima1,∗. , Kenta Fujisawa2, Masaaki Hayashida3. & Naoki Isobe4. 1Shanghai Astronomical Observatory, Chinese Academy of Sciences,.

  13. Extrinsic stretching narrowing and anterior indentation of the rectosigmoid junction

    International Nuclear Information System (INIS)

    Schulman, A.; Fataar, S.

    1979-01-01

    Thirty-five cases of extrinsic narrowing or anterior indentation of the rectosigmoid junction (RSJ) have been studied. The RSJ lies directly behind the pouch of Douglas which is a favoured site for peritoneal metastasis, abscess and endometriosis. Any space-occupying lesion of sufficient size at this site will indent the anterior aspects of the RSJ. Causes include distension or tumour of the ileum or sigmoid colon, gross ascites (when the patient is erect), and tumours below the pelvic peritonium, such as gynaecological neoplasm and internal iliac artery aneurysm. When a desmoplastic metastasis in the pouch of Douglas infiltrates the outer layers of the RSJ, the fibrosis produces an eccentric shortening on its anterior aspect, which in turn causes a pleating of the mucosa with the folds radiating towards the shortened area. This is also seen with primary pelvic carcinomas directly adherent to the rectum, endometriosis with repeated bleeding and increasing eccentric, submucosal fibrosis, and chronic abscess in the pouch of Douglas. Not all extrinsic narrowing of the RSJ are pathological. One case of anterior indentation followed operation for rectal prolapse. Ten additional cases showed narrowing due to a technical artefact air-distended colon rising into the upper abdomen to cause stretching at the RSJ. As with ascites, this narrowing due to 'high-rise sigmoid' disappeared when the patients became recumbent and the colonic air redistributed. (author)

  14. Narrow coherent effects in πNN-dynamics

    International Nuclear Information System (INIS)

    Kudryavtsev, A.E.; Obrant, G.Z.

    1990-01-01

    Coherent effect production is considered in πNN-dynamics with resonant pion-nucleon interaction via Brueckner theory and Faddev equations. It is shown that the narrow energy and final momentum dependence can arise in the inelastic S-wave πd-scattering. The energy dependence peculiarities can have a width an order magnitude less than πN-resonance one

  15. A "Narrowing of Inquiry" in American Moral Psychology and Education

    Science.gov (United States)

    Richardson, Michael J.; Slife, Brent D.

    2013-01-01

    We explore the possibility that a priori philosophical commitments continue to result in a narrowing of inquiry in moral psychology and education where theistic worldviews are concerned. Drawing from the theories of Edward L. Thorndike and John Dewey, we examine naturalistic philosophical commitments that influenced the study of moral psychology…

  16. Ultra high energy cosmic rays

    International Nuclear Information System (INIS)

    Watson, A.A.

    1986-01-01

    Cosmic radiation was discovered 70 years ago but its origin remains an open question. The background to this problem is outlined and attempts to discover the origin of the most energetic and rarest group above 10 15 eV are described. Measurements of the energy spectrum and arrival direction pattern of the very highest energy particles, mean energy about 6 x 10 19 eV, are used to argue that these particles originate outside our galaxy. Recent evidence from the new field of ultra high energy γ-ray astronomy are discussed in the context of a galactic origin hypothesis for lower energy cosmic rays. (author)

  17. The MAJORANA experiment: an ultra-low background search for neutrinoless double-beta decay

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, D.; Aguayo Navarrete, Estanislao; Avignone, Frank T.; Back, Henning O.; Barabash, Alexander S.; Bergevin, M.; Bertrand, F.; Boswell, M.; Brudanin, V.; Busch, Matthew; Chan, Yuen-Dat; Christofferson, Cabot-Ann; Collar, J. I.; Combs, Dustin C.; Cooper, R. J.; Detwiler, Jason A.; Doe, Peter J.; Efremenko, Yuri; Egorov, Viatcheslav; Ejiri, H.; Elliott, Steven R.; Esterline, James H.; Fast, James E.; Fields, N.; Finnerty, P.; Fraenkle, Florian; Gehman, Victor; Giovanetti, G. K.; Green, Matthew P.; Guiseppe, Vincente; Gusey, K.; Hallin, A. L.; Hazama, R.; Henning, Reyco; Hime, Andrew; Hoppe, Eric W.; Horton, Mark; Howard, Stanley; Howe, M. A.; Johnson, R. A.; Keeter, K.; Keller, C.; Kidd, Mary; Knecht, A.; Kochetov, Oleg; Konovalov, S.; Kouzes, Richard T.; LaFerriere, Brian D.; LaRoque, B. H.; Leon, Jonathan D.; Leviner, L.; Loach, J. C.; MacMullin, S.; Marino, Michael G.; Martin, R. D.; Mei, Dong-Ming; Merriman, Jason H.; Miller, M. L.; Mizouni, Leila; Nomachi, Masaharu; Orrell, John L.; Overman, Nicole R.; Poon, Alan; Perumpilly, Gopakumar; Prior, Gersende; Radford, D. C.; Rielage, Keith; Robertson, R. G. H.; Ronquest, M. C.; Schubert, Alexis G.; Shima, T.; Shirchenko, M.; Snavely, Kyle J.; Steele, David; Strain, J.; Thomas, K.; Timkin, V.; Tornow, W.; Vanyushin, I.; Varner, R. L.; Vetter, Kai; Vorren, Kris R.; Wilkerson, J. F.; Wolfe, B. A.; Yakushev, E.; Young, A.; Yu, Chang-Hong; Yumatov, Vladimir; Zhang, C.

    2012-12-01

    The observation of neutrinoless double-beta decay would resolve the Majorana nature of the neutrino and could provide information on the absolute scale of the neutrino mass. The initial phase of the Majorana Experiment, known as the Demonstrator, will house 40 kg of Ge in an ultra-low background shielded environment at the 4850' level of the Sanford Underground Laboratory in Lead, SD. The objective of the Demonstrator is to validate whether a future 1-tonne experiment can achieve a background goal of one count per tonne-year in a narrow region of interest around the 76Ge neutrinoless double-beta decay peak.

  18. Biomechanical comparison of single-row, double-row, and transosseous-equivalent repair techniques after healing in an animal rotator cuff tear model.

    Science.gov (United States)

    Quigley, Ryan J; Gupta, Akash; Oh, Joo-Han; Chung, Kyung-Chil; McGarry, Michelle H; Gupta, Ranjan; Tibone, James E; Lee, Thay Q

    2013-08-01

    The transosseous-equivalent (TOE) rotator cuff repair technique increases failure loads and contact pressure and area between tendon and bone compared to single-row (SR) and double-row (DR) repairs, but no study has investigated if this translates into improved healing in vivo. We hypothesized that a TOE repair in a rabbit chronic rotator cuff tear model would demonstrate a better biomechanical profile than SR and DR repairs after 12 weeks of healing. A two-stage surgical procedure was performed on 21 New Zealand White Rabbits. The right subscapularis tendon was transected and allowed to retract for 6 weeks to simulate a chronic tear. Repair was done with the SR, DR, or TOE technique and allowed to heal for 12 weeks. Cyclic loading and load to failure biomechanical testing was then performed. The TOE repair showed greater biomechanical characteristics than DR, which in turn were greater than SR. These included yield load (p repair of a chronic, retracted rotator cuff tear, the TOE technique was the strongest biomechanical construct after healing followed by DR with SR being the weakest. Copyright © 2013 Orthopaedic Research Society.

  19. A biomechanical analysis of point of failure during lateral-row tensioning in transosseous-equivalent rotator cuff repair.

    Science.gov (United States)

    Dierckman, Brian D; Goldstein, Jordan L; Hammond, Kyle E; Karas, Spero G

    2012-01-01

    The purpose of this study was to determine the maximum load and point of failure of the construct during tensioning of the lateral row of a transosseous-equivalent (TOE) rotator cuff repair. In 6 fresh-frozen human shoulders, a TOE rotator cuff repair was performed, with 1 suture from each medial anchor passed through the tendon and tied in a horizontal mattress pattern. One of 2 limbs from each of 2 medial anchors was pulled laterally over the tendon. After preparation of the lateral bone for anchor placement, the 2 limbs were passed through the polyether ether ketone (PEEK) eyelet of a knotless anchor and tied to a tensiometer. The lateral anchor was placed into the prepared bone tunnel but not fully seated. Tensioning of the lateral-row repair was simulated by pulling the tensiometer to tighten the suture limbs as they passed through the eyelet of the knotless anchor. The mode of failure and maximum tension were recorded. The procedure was then repeated for the second lateral-row anchor. The mean load to failure during lateral-row placement in the TOE model was 80.8 ± 21.0 N (median, 83 N; range, 27.2 to 115.8 N). There was no statistically significant difference between load to failure during lateral-row tensioning for the anterior and posterior anchors (P = .84). Each of the 12 constructs failed at the eyelet of the lateral anchor. Retrieval analysis showed no failure of the medial anchors, no medial suture cutout through the rotator cuff tendon, and no signs of gapping at the repair site. Our results suggest that the medial-row repair does not appear vulnerable during tensioning of the lateral row of a TOE rotator cuff repair with the implants tested. However, surgeons should exercise caution when tensioning the lateral row, especially when lateral-row anchors with PEEK eyelets are implemented. For this repair construct, the findings suggest that although the medial row is not vulnerable during lateral-row tensioning of a TOE rotator cuff repair, lateral-row

  20. Ultra-thin chip technology and applications

    CERN Document Server

    2010-01-01

    Ultra-thin chips are the "smart skin" of a conventional silicon chip. This book shows how very thin and flexible chips can be fabricated and used in many new applications in microelectronics, microsystems, biomedical and other fields. It provides a comprehensive reference to the fabrication technology, post processing, characterization and the applications of ultra-thin chips.

  1. Subset-row inequalities applied to the vehicle routing problem with time windows

    DEFF Research Database (Denmark)

    Jepsen, Mads Kehlet; Petersen, Bjørn; Spoorendonk, Simon

    2008-01-01

    constraints as the pricing problem. We introduce the subset-row inequalities, which are Chvatal-Gomory rank-1 cuts based on a subset of the constraints in the master problem. Applying a subset-row inequality in the master problem increases the complexity of the label-setting algorithm used to solve......This paper presents a branch-and-cut-and-price algorithm for the vehicle-routing problem with time windows. The standard Dantzig-Wolfe decomposition of the arc flow formulation leads to a set-partitioning problem as the master problem and an elementary shortest-path problem with resource...... the pricing problem because an additional resource is added for each inequality. We propose a modified dominance criterion that makes it possible to dominate more labels by exploiting the step-like structure of the objective function of the pricing problem. Computational experiments have been performed...

  2. Row Reduction Applied to Decoding of Rank Metric and Subspace Codes

    DEFF Research Database (Denmark)

    Puchinger, Sven; Nielsen, Johan Sebastian Rosenkilde; Li, Wenhui

    2017-01-01

    We show that decoding of ℓ-Interleaved Gabidulin codes, as well as list-ℓ decoding of Mahdavifar–Vardy (MV) codes can be performed by row reducing skew polynomial matrices. Inspired by row reduction of F[x] matrices, we develop a general and flexible approach of transforming matrices over skew...... polynomial rings into a certain reduced form. We apply this to solve generalised shift register problems over skew polynomial rings which occur in decoding ℓ-Interleaved Gabidulin codes. We obtain an algorithm with complexity O(ℓμ2) where μ measures the size of the input problem and is proportional...... to the code length n in the case of decoding. Further, we show how to perform the interpolation step of list-ℓ-decoding MV codes in complexity O(ℓn2), where n is the number of interpolation constraints....

  3. Analyzing Permutations for AES-like Ciphers: Understanding ShiftRows

    DEFF Research Database (Denmark)

    Beierle, Christof; Jovanovic, Philipp; Lauridsen, Martin Mehl

    2015-01-01

    Designing block ciphers and hash functions in a manner that resemble the AES in many aspects has been very popular since Rijndael was adopted as the Advanced Encryption Standard. However, in sharp contrast to the MixColumns operation, the security implications of the way the state is permuted...... by the operation resembling ShiftRows has never been studied in depth. Here, we provide the first structured study of the influence of ShiftRows-like operations, or more generally, word-wise permutations, in AES-like ciphers with respect to diffusion properties and resistance towards differential- and linear...... normal form. Using a mixed-integer linear programming approach, we obtain optimal parameters for a wide range of AES-like ciphers, and show improvements on parameters for Rijndael-192, Rijndael-256, PRIMATEs-80 and Prøst-128. As a separate result, we show for specific cases of the state geometry...

  4. 3-D Vector Flow Using a Row-Column Addressed CMUT Array

    DEFF Research Database (Denmark)

    Holbek, Simon; Christiansen, Thomas Lehrmann; Engholm, Mathias

    2016-01-01

    This paper presents an in-house developed 2-D capacitive micromachined ultrasonic transducer (CMUT) appliedfor 3-D blood flow estimation. The probe breaks with conventional transducers in two ways; first, the ultrasonicpressure field is generated from thousands of small vibrating micromachined...... cells, and second, elements areaccessed by row and/or column indices. The 62+62 2-D row-column addressed prototype CMUT probe was usedfor vector flow estimation by transmitting focused ultrasound into a flow-rig with a fully developed parabolicflow. The beam-to-flow angle was 90◦. The received data...... was beamformed and processed offline. A transverseoscillation (TO) velocity estimator was used to estimate the 3-D vector flow along a line originating from thecenter of the transducer. The estimated velocities in the lateral and axial direction were close to zero as expected.In the transverse direction...

  5. A low complexity reweighted proportionate affine projection algorithm with memory and row action projection

    Science.gov (United States)

    Liu, Jianming; Grant, Steven L.; Benesty, Jacob

    2015-12-01

    A new reweighted proportionate affine projection algorithm (RPAPA) with memory and row action projection (MRAP) is proposed in this paper. The reweighted PAPA is derived from a family of sparseness measures, which demonstrate performance similar to mu-law and the l 0 norm PAPA but with lower computational complexity. The sparseness of the channel is taken into account to improve the performance for dispersive system identification. Meanwhile, the memory of the filter's coefficients is combined with row action projections (RAP) to significantly reduce computational complexity. Simulation results demonstrate that the proposed RPAPA MRAP algorithm outperforms both the affine projection algorithm (APA) and PAPA, and has performance similar to l 0 PAPA and mu-law PAPA, in terms of convergence speed and tracking ability. Meanwhile, the proposed RPAPA MRAP has much lower computational complexity than PAPA, mu-law PAPA, and l 0 PAPA, etc., which makes it very appealing for real-time implementation.

  6. Experiment and analysis of instability of tube rows subject to liquid crossflow

    International Nuclear Information System (INIS)

    Chen, S.S.; Jendrzejczyk, J.A.

    1981-09-01

    A tube array subjected to crossflow may become unstable by either one or both of the two basic mechanisms: velocity mechanism and displacement mechanism. The significance of these two mechanisms depends on the mass-damping parameter. The velocity mechanism is dominant for tube arrays with a low mass-damping parameter, and the displacement mechanism is dominant for tube arrays with a high mass-damping parameter. This report presents an experimental and analytical investigation of tube rows in liquid crossflow. The main objective is to verify a mathematical model and the transition between the two mechanisms at the intermediate values of mass-damping parameter. Tests of two tube rows are conducted to determine the critical flow velocity as a function of system damping. Experimental and analytical results are found to be in good agreement

  7. A virtual trainer concept for robot-assisted human motor learning in rowing

    Directory of Open Access Journals (Sweden)

    Baumgartner L.

    2011-12-01

    Full Text Available Keeping the attention level and observing multiple physiological and biomechanical variables at the same time at high precision is very challenging for human trainers. Concurrent augmented feedback, which is suggested to enhance motor learning in complex motor tasks, can also hardly be provided by a human trainer. Thus, in this paper, a concept for a virtual trainer is presented that may overcome the limits of a human trainer. The intended virtual trainer will be implemented in a CAVE providing auditory, visual and haptic cues. As a first application, the virtual trainer will be used in a realistic scenario for sweep rowing. To provide individual feedback to each rower, the virtual trainer quantifies errors and provides concurrent auditory, visual, and haptic feedback. The concurrent feedback will be adapted according to the actual performance, individual maximal rowing velocity, and the athlete’s individual perception.

  8. Performance of a Low Speed Axial Compressor Rotor Blade Row under Different Inlet Distortions

    Directory of Open Access Journals (Sweden)

    R. Taghavi Zenouz

    2017-05-01

    Full Text Available Responses of an axial compressor isolated rotor blade row to various inlet distortions have been investigated utilizing computational fluid dynamic technique. Distortions have been imposed by five screens of different geometries, but with the same blockage ratio. These screens were embedded upstream of the rotor blade row. Flow fields are simulated in detail for compressor design point and near stall conditions. Performance curves for distorted cases are extracted and compared to the undisturbed case. Flow simulations and consequent performance characteristics show that the worst cases belong to non-symmetric blockages, i.e., those of partial circumferential configurations. These cases produce the largest wakes which can disturb the flow, considerably. Superior performances correspond to the inner and outer continuous circumferential distortion screens. Since, they produce no significant disturbances to the main flow in comparison to the non-symmetric screens.

  9. Ultra-Deepwater Production Systems

    Energy Technology Data Exchange (ETDEWEB)

    Ken L. Smith; Marc E. Leveque

    2005-05-31

    The report herein is a summary of the work performed on three projects to demonstrate hydrocarbon drilling and production methods applicable to deep and ultra deepwater field developments in the Gulf of Mexico and other like applications around the world. This work advances technology that could lead to more economic development and exploitation of reserves in ultra-deep water or remote areas. The first project is Subsea Processing. Its scope includes a review of the ''state of the art'' in subsea components to enable primary production process functions such as first stage liquids and gas separation, flow boosting, chemical treatment, flow metering, etc. These components are then combined to allow for the elimination of costly surface production facilities at the well site. A number of studies were then performed on proposed field development projects to validate the economic potential of this technology. The second project involved the design and testing of a light weight production riser made of composite material. The proposed design was to meet an actual Gulf of Mexico deepwater development project. The various engineering and testing work is reviewed, including test results. The third project described in this report encompasses the development and testing of a close tolerance liner drilling system, a new technology aimed at reducing deepwater drilling costs. The design and prototype testing in a test well are described in detail.

  10. Age and sex differences in paranormal beliefs: a response to Vitulli, Tipton, and Rowe (1999)

    Science.gov (United States)

    Irwin, H J

    2000-04-01

    Vitulli, Tipton, and Rowe (1999) report evidence of age and sex differences in the strength of paranormal beliefs. An alternative interpretation of their data is offered in terms of differential item functioning. It is suggested that respondents' interpretation of paranormal belief test items may vary with age and sex, and that such differences in the strength with which such beliefs are endorsed has not been conclusively established by Vitulli, et al.

  11. Users’ Perceptions on Pedestrian Prioritized Neighborhoods: a study on Terrace Row Housing Estates in Malaysia

    OpenAIRE

    Tareef Hayat Khan; Abubakar Danladi Isah; Elahe Anjomshoaa; Soheil Sabri

    2015-01-01

    Malaysia is currently enjoying an overhang of housing supply. The focus is gradually shifting from providing just a mere shelter to something more socially. Terrace row housing estates in Malaysia is the major prototype of housing in the country. Pedestrian activities are catalyst to social interaction, but have been ignored in this model. During the last century, motor age established the supremacy of car prioritized models over that of pedestrians around the world, Malaysia has ...

  12. KSC technician installs rows of experiment racks in IML-1 spacelab module

    Science.gov (United States)

    1991-01-01

    Kennedy Space Center (KSC) technician installs rows of experiment racks in the International Microgravity Laboratory 1 (IML-1) in the KSC Operations and Checkout (O and C) Bldg. The IML-1 is scheduled to fly on STS-42 in early 1992, and will turn the shuttle into a laboratory dedicated to investigating the effects of microgravity on materials and life processes. View provided by KSC with alternate number KSC-91P-169.

  13. Multidetector-row CT finding of gastric cystic lymphangioma: A case report

    International Nuclear Information System (INIS)

    Kang, Tae Wook; Lee, Soon Jin; Song, Hye Jong

    2008-01-01

    Cystic lymphangioma is a rare benign submucosal tumor of the stomach thought to originate from sequestered lymphatic tissue that fails to communicate with the normal lymphatic system. The most commonly used method of evaluation for cystic lymphangioma of the stomach is an endoscopic ultrasonography. We report the multidetector-row computed tomography findings of a cystic lymphangioma of the stomach in a 46-year-old man along with a literature review

  14. Multi-sensor fusion method for crop row tracking and traversability operations

    OpenAIRE

    Benet, B.; Lenain, R.

    2017-01-01

    Precision agriculture vehicles need autonomous navigation in cultures to carry out their tasks, such as planting, maintenance and harvesting in cultures such as vegetable, vineyard, or horticulture. The detection of natural objects like trunks, grass, leaf, or obstacles in front of vehicle in crop row is crucial for safe navigation. Sensors such as LiDAR devices or Time Of Flight cameras (TOF), allow to obtain geometric data in natural environment, using information of an Inertial Measurement...

  15. Impacts of tree rows on grassland birds and potential nest predators: a removal experiment.

    Science.gov (United States)

    Ellison, Kevin S; Ribic, Christine A; Sample, David W; Fawcett, Megan J; Dadisman, John D

    2013-01-01

    Globally, grasslands and the wildlife that inhabit them are widely imperiled. Encroachment by shrubs and trees has widely impacted grasslands in the past 150 years. In North America, most grassland birds avoid nesting near woody vegetation. Because woody vegetation fragments grasslands and potential nest predator diversity and abundance is often greater along wooded edge and grassland transitions, we measured the impacts of removing rows of trees and shrubs that intersected grasslands on potential nest predators and the three most abundant grassland bird species (Henslow's sparrow [Ammodramus henslowii], Eastern meadowlark [Sturnella magna], and bobolink [Dolichonyx oryzivorus]) at sites in Wisconsin, U.S.A. We monitored 3 control and 3 treatment sites, for 1 yr prior to and 3 yr after tree row removal at the treatment sites. Grassland bird densities increased (2-4 times for bobolink and Henslow's sparrow) and nesting densities increased (all 3 species) in the removal areas compared to control areas. After removals, Henslow's sparrows nested within ≤50 m of the treatment area, where they did not occur when tree rows were present. Most dramatically, activity by woodland-associated predators nearly ceased (nine-fold decrease for raccoon [Procyon lotor]) at the removals and grassland predators increased (up to 27 times activity for thirteen-lined ground squirrel [Ictidomys tridecemlineatus]). Nest success did not increase, likely reflecting the increase in grassland predators. However, more nests were attempted by all 3 species (175 versus 116) and the number of successful nests for bobolinks and Henslow's sparrows increased. Because of gains in habitat, increased use by birds, greater production of young, and the effective removal of woodland-associated predators, tree row removal, where appropriate based on the predator community, can be a beneficial management action for conserving grassland birds and improving fragmented and degraded grassland ecosystems.

  16. Impacts of tree rows on grassland birds and potential nest predators: a removal experiment.

    Directory of Open Access Journals (Sweden)

    Kevin S Ellison

    Full Text Available Globally, grasslands and the wildlife that inhabit them are widely imperiled. Encroachment by shrubs and trees has widely impacted grasslands in the past 150 years. In North America, most grassland birds avoid nesting near woody vegetation. Because woody vegetation fragments grasslands and potential nest predator diversity and abundance is often greater along wooded edge and grassland transitions, we measured the impacts of removing rows of trees and shrubs that intersected grasslands on potential nest predators and the three most abundant grassland bird species (Henslow's sparrow [Ammodramus henslowii], Eastern meadowlark [Sturnella magna], and bobolink [Dolichonyx oryzivorus] at sites in Wisconsin, U.S.A. We monitored 3 control and 3 treatment sites, for 1 yr prior to and 3 yr after tree row removal at the treatment sites. Grassland bird densities increased (2-4 times for bobolink and Henslow's sparrow and nesting densities increased (all 3 species in the removal areas compared to control areas. After removals, Henslow's sparrows nested within ≤50 m of the treatment area, where they did not occur when tree rows were present. Most dramatically, activity by woodland-associated predators nearly ceased (nine-fold decrease for raccoon [Procyon lotor] at the removals and grassland predators increased (up to 27 times activity for thirteen-lined ground squirrel [Ictidomys tridecemlineatus]. Nest success did not increase, likely reflecting the increase in grassland predators. However, more nests were attempted by all 3 species (175 versus 116 and the number of successful nests for bobolinks and Henslow's sparrows increased. Because of gains in habitat, increased use by birds, greater production of young, and the effective removal of woodland-associated predators, tree row removal, where appropriate based on the predator community, can be a beneficial management action for conserving grassland birds and improving fragmented and degraded grassland

  17. Testing functional and morphological interpretations of enamel thickness along the deciduous tooth row in human children.

    OpenAIRE

    Mahoney, Patrick

    2013-01-01

    The significance of a gradient in enamel thickness along the human permanent molar row has been debated in the literature. Some attribute increased enamel thickness from first to third molars to greater bite force during chewing. Others argue that thicker third molar enamel relates to a smaller crown size facilitated by a reduced dentin component. Thus, differences in morphology, not function, explains enamel thickness. This study draws on these different interpretive models to assess enamel ...

  18. Electron distributions of the first-row homonuclear diatomic molecules, A2

    International Nuclear Information System (INIS)

    Ramirez, B.I.; Bielefeld Univ.

    1982-08-01

    Electron momentum density contour maps of the first-row homonuclear diatomic molecules, A 2 , are obtained from near Hartree-Fock wave functions. Both the total momentum density and momentum density difference (molecule - isolated atoms) maps present trends that may be related to the binding in the molecules. These results are compared with the corresponding charge density maps in position space (Bader, Henneker and Cade 1967). (author)

  19. FES-Rowing versus Zoledronic Acid to Improve BoneHealth in SCI

    Science.gov (United States)

    2016-12-01

    Army position, policy or decision unless so designated by other documentation. REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public...no established treatment to prevent bone loss or to induce new bone formation following SCI. The goal of this clinical trial -- FES-Rowing versus...infusion at the VA Boston Healthcare-Jamaica Plain Campus. The nurse practitioner that administered the infusion made follow-up phone calls within 24

  20. Influence of intra-row spacing and mulching on weed growth and ...

    African Journals Online (AJOL)

    hope&shola

    2006-02-02

    Feb 2, 2006 ... response of weed growth and bulb yield of garlic to intra-row spacing and mulching. ... advantageous effects on the growth and yield of this crop. ... Portulaca oleracea L x xx .... 50DAP. 60DAP. Spacing (cm). 20 x 10. 2.60b. 4.69. 6.34b. 12.54b. 2.68. 3.90 .... Effect of plant spacing and nitrogen fertilization on.

  1. Irrigation, Planting Date And Intra-Row Spacing Effects On Soybean Grown Under Dry Farming Systems

    OpenAIRE

    Ismail, A. M. A. [احمد محمد علي اسماعيل; Khalifa, F. M.

    1987-01-01

    Two soybean cultivars (Glycine maxima (L) Merr.) differing in maturity period, leaf size and stem height were sown five times at fortnight intervals during the rainy season at four intra—row spacings under supplementary irrigation at one site and under rainfed conditions at another site in the central rainlands of Sudan. Cultivars responded differently to the system of production. Sowing date and moisture availability were the main factors controlling soybean production. The late maturing cul...

  2. Factors affecting healing rates after arthroscopic double-row rotator cuff repair.

    Science.gov (United States)

    Tashjian, Robert Z; Hollins, Anthony M; Kim, Hyun-Min; Teefey, Sharlene A; Middleton, William D; Steger-May, Karen; Galatz, Leesa M; Yamaguchi, Ken

    2010-12-01

    Double-row arthroscopic rotator cuff repairs were developed to improve initial biomechanical strength of repairs to improve healing rates. Despite biomechanical improvements, failure of healing remains a clinical problem. To evaluate the anatomical results after double-row arthroscopic rotator cuff repair with ultrasound to determine postoperative repair integrity and the effect of various factors on tendon healing. Case series; Level of evidence, 4. Forty-eight patients (49 shoulders) who had a complete arthroscopic rotator cuff repair (double-row technique) were evaluated with ultrasound at a minimum of 6 months after surgery. Outcome was evaluated at a minimum of 1-year follow-up with standardized history and physical examination, visual analog scale for pain, active forward elevation, and preoperative and postoperative shoulder scores according to the system of the American Shoulder and Elbow Surgeons and the Simple Shoulder Test. Quantitative strength was measured postoperatively. Ultrasound and physical examinations were performed at a minimum of 6 months after surgery (mean, 16 months; range, 6 to 36 months) and outcome questionnaire evaluations at a minimum of 12 months after surgery (mean, 29 months; range, 12 to 55 months). Of 49 repairs, 25 (51%) were healed. Healing rates were 67% in single-tendon tears (16 of 24 shoulders) and 36% in multitendon tears (9 of 25 shoulders). Older age and longer duration of follow-up were correlated with poorer tendon healing (P repair (P rotator cuff repair. The biological limitation at the repair site, as reflected by the effects of age on healing, appears to be the most important factor influencing tendon healing, even after maximizing repair biomechanical strength with a double-row construct.

  3. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT; Evaluation der Strahlendosis bei Polytrauma-CT-Untersuchungen eines 64-Zeilen-CT im Vergleich zur 4-Zeilen-CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U. [Ludwig-Maximilians-Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2012-05-15

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI{sub vol} values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 {+-} 2.5 vs. 11.4 {+-} 1.4, p < 0.001; 14.2 {+-} 3.7 vs. 16.1 {+-} 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 {+-} 201.1 vs. 849.8 {+-} 90.9, p < 0,001; 504.4 {+-} 134.4 vs. 471.5 {+-} 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 {+-} 35.8 vs. 155.5 {+-} 12.3 (p < 0.001), thorax 427.4 {+-} 44.5 vs. 388.3 {+-} 57.5 (p < 0.001), abdomen 520.3 {+-} 50.2 vs. 490.8 {+-} 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 {+-} 2.6 (4-row MDCT) and 24.1 {+-} 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  4. Consumers' conceptualization of ultra-processed foods.

    Science.gov (United States)

    Ares, Gastón; Vidal, Leticia; Allegue, Gimena; Giménez, Ana; Bandeira, Elisa; Moratorio, Ximena; Molina, Verónika; Curutchet, María Rosa

    2016-10-01

    Consumption of ultra-processed foods has been associated with low diet quality, obesity and other non-communicable diseases. This situation makes it necessary to develop educational campaigns to discourage consumers from substituting meals based on unprocessed or minimally processed foods by ultra-processed foods. In this context, the aim of the present work was to investigate how consumers conceptualize the term ultra-processed foods and to evaluate if the foods they perceive as ultra-processed are in concordance with the products included in the NOVA classification system. An online study was carried out with 2381 participants. They were asked to explain what they understood by ultra-processed foods and to list foods that can be considered ultra-processed. Responses were analysed using inductive coding. The great majority of the participants was able to provide an explanation of what ultra-processed foods are, which was similar to the definition described in the literature. Most of the participants described ultra-processed foods as highly processed products that usually contain additives and other artificial ingredients, stressing that they have low nutritional quality and are unhealthful. The most relevant products for consumers' conceptualization of the term were in agreement with the NOVA classification system and included processed meats, soft drinks, snacks, burgers, powdered and packaged soups and noodles. However, some of the participants perceived processed foods, culinary ingredients and even some minimally processed foods as ultra-processed. This suggests that in order to accurately convey their message, educational campaigns aimed at discouraging consumers from consuming ultra-processed foods should include a clear definition of the term and describe some of their specific characteristics, such as the type of ingredients included in their formulation and their nutritional composition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Preoperative assessment of hilar cholangiocarcinoma using multidetector-row CT. Correlation with histopathological findings

    International Nuclear Information System (INIS)

    Watadani, Takeyuki; Akahane, Masaaki; Ohtomo, Kuni; Yoshikawa, Takeharu

    2008-01-01

    Our aim was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for preoperative assessment of local tumoral spread in hilar cholangiocarcinoma. Thirteen of 30 consecutive patients with hilar cholangiocarcinoma who underwent surgery, excluding 17 patients who underwent biliary drainage or preoperative portal embolization, were retrospectively evaluated. Using MDCT systems of 4 detector rows or 16 detector rows, plain and dynamic contrast-enhanced images of three phases were obtained. Extent of tumor spread and lymph node metastasis were assessed with MDCT and compared with histopathological findings. The Bismuth-Corlette classification of hilar cholangiocarcinoma with MDCT were type I, 1 patient; type IIIa, 3 patients; type IIIb, 4 patients; and type IV, 5 patients; those with histopathological findings were type I, 1 patient; type IIIa, 2 patients; type IIIb, 4 patients; and type IV, 6 patients. One patient diagnosed as type IIIa with MDCT was pathologically diagnosed as type IV. Accuracy of MDCT in tumoral spread was 92.3%, although that of lymph node metastasis was 54%. MDCT is likely to play an important role in evaluation of focal lesion spread especially in intrapancreatic tumor invasion, although a greater number of cohort cases are necessary to clearly define its role. (author)

  6. Imaging of peripheral arteries by 16-row multidetector computed tomography angiography: A feasible tool?

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, Anuj [Department of Radiology, National Organ Transplant Program, Tripoli (Libyan Arab Jamahiriya)]. E-mail: dranujmish@yahoo.com; Bhaktarahalli, Jahnavi Narayanaswamy [Department of Clinical Pathology, Tripoli Medical Centre, Tripoli (Libyan Arab Jamahiriya); Ehtuish, Ehtuish F. [Department of Surgery, National Organ Transplant Program, Tripoli (Libyan Arab Jamahiriya)

    2007-03-15

    Objective: To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral arterial occlusive disease (PAOD). Methods: Thirty-three patients underwent MDCT angiography (MDCTA) of the upper or the lower limb on 16-row MDCT scanner between November, 2004 and July, 2005. The findings were compared with the surgical outcome in cases with trauma and suspected arterial injuries or color Doppler correlation was obtained for patients of PAOD. Results: MDCTA allowed a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In the 23 cases of PAOD, MDCT adequately demonstrated the presence of stenosis or occlusion, its degree and extent, the presence of collaterals and plaques. Conclusion: Our experience of CT angiography (CTA) with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries and as a useful screening modality in cases of PAOD for diagnosis and for grading.

  7. Imaging of peripheral arteries by 16-row multidetector computed tomography angiography: A feasible tool?

    International Nuclear Information System (INIS)

    Mishra, Anuj; Bhaktarahalli, Jahnavi Narayanaswamy; Ehtuish, Ehtuish F.

    2007-01-01

    Objective: To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral arterial occlusive disease (PAOD). Methods: Thirty-three patients underwent MDCT angiography (MDCTA) of the upper or the lower limb on 16-row MDCT scanner between November, 2004 and July, 2005. The findings were compared with the surgical outcome in cases with trauma and suspected arterial injuries or color Doppler correlation was obtained for patients of PAOD. Results: MDCTA allowed a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In the 23 cases of PAOD, MDCT adequately demonstrated the presence of stenosis or occlusion, its degree and extent, the presence of collaterals and plaques. Conclusion: Our experience of CT angiography (CTA) with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries and as a useful screening modality in cases of PAOD for diagnosis and for grading

  8. A CFD analysis of blade row interactions within a high-speed axial compressor

    Science.gov (United States)

    Richman, Michael Scott

    Aircraft engine design provides many technical and financial hurdles. In an effort to streamline the design process, save money, and improve reliability and performance, many manufacturers are relying on computational fluid dynamic simulations. An overarching goal of the design process for military aircraft engines is to reduce size and weight while maintaining (or improving) reliability. Designers often turn to the compression system to accomplish this goal. As pressure ratios increase and the number of compression stages decrease, many problems arise, for example stability and high cycle fatigue (HCF) become significant as individual stage loading is increased. CFD simulations have recently been employed to assist in the understanding of the aeroelastic problems. For accurate multistage blade row HCF prediction, it is imperative that advanced three-dimensional blade row unsteady aerodynamic interaction codes be validated with appropriate benchmark data. This research addresses this required validation process for TURBO, an advanced three-dimensional multi-blade row turbomachinery CFD code. The solution/prediction accuracy is characterized, identifying key flow field parameters driving the inlet guide vane (IGV) and stator response to the rotor generated forcing functions. The result is a quantified evaluation of the ability of TURBO to predict not only the fundamental flow field characteristics but the three dimensional blade loading.

  9. Fungal Distribution and Varieties Resistance to Kernel Discoloration in Korean Two-rowed Barley

    Directory of Open Access Journals (Sweden)

    Sang-Hyun Shin

    2013-09-01

    Full Text Available Barley kernel discoloration (KD leads to substantial loss in value through downgrading and discounting of malting barley. The objective of this research is to investigate fungal distribution and varieties resistance to KD in Korean two-rowed barley. Several fungal organisms including Alternaria spp., Fusarium spp., Aspergillus spp., Epicoccum spp. and Rhizopus spp. were isolated from Korean two-rowed barley representing KD. The symptoms of KD were brown and black discolorations of the lemma and palea. The most frequently detected fungal species was Alternaria spp. which exhibited 69.1% and 72.2% in 2011 and 2012, respectively. Epicoccum spp., Fusarium spp., and Aspergillus spp. were also detected. Fusarium spp., primary pathogen of barley head blight, were rarely occurred in the 2011 and their occurrence increased to 4.7% in 2012. Twenty cultivars of Korean two-rowed barely were evaluated to KD. The average percentage of KD was 8.0−36.0% in 2011 and 5.2−36.6% in 2012. Two cultivars (‘Sacheon 6’ and ‘Dajinbori’ showed KD of 6.2% to 8.8% and determined resistant, however ‘Samdobori’ and ‘Daeyeongbori’ demonstrating KD of 22.2−36.6% were highly susceptible. ‘Jinyangbori’, ‘Danwonbori’, ‘Sinhobori’ and ‘Kwangmaegbori’ showing KD of less than 15% were moderately resistant cultivar.

  10. [Open double-row rotator cuff repair using the LASA-DR screw].

    Science.gov (United States)

    Schoch, C; Geyer, S; Geyer, M

    2016-02-01

    Safe and cost-effective rotator-cuff repair. All types of rotator cuff lesions. Frozen shoulder, rotator cuff mass defect, defect arthropathy. Extensive four-point fixation on the bony footprint is performed using the double-row lateral augmentation screw anchor (LASA-DR) with high biomechanical stability. Following mobilization of the tendons, these are refixed in the desired configuration first medially and then laterally. To this end, two drilling channels (footprint and lateral tubercle) are created for each screw. Using the shuttle technique, a suture anchor screw is reinforced with up to four pairs of threads. The medial row is then pierced and tied, and the sutures that have been left long are tied laterally around the screw heads (double row). 4 Weeks abduction pillow, resulting in passive physiotherapy, followed by initiation of active assisted physiotherapy. Full weight-bearing after 4-6 months. Prospective analysis of 35 consecutive Bateman-III lesions with excellent results and low rerupture rate (6%).

  11. Evaluation of 16 detector row spiral CT in diagnosing pulmonary embolism

    International Nuclear Information System (INIS)

    Yu Xiaokun; Li Lei

    2008-01-01

    Objective: To investigate the value of 16 detector row spiral CT in the diagnosis of pulmonary embolism(PE). Methods: Imaging data of 20 patients (plain 16 detector row spiral CT scanning plus enhanced scanning imaging) highly suspected of PE was retrospectively analyzed. Results: Among the 20 cases, embolism was showed in 13 patients on 16 detector row spiral CT pulmonary angiography (MSCTPA). 6 cases of the 13 PE's patients have masculine findings on plain MSCT scanning images. Localized tenuous lung markings, dilated pulmonary artery, 'mosaic' sign, pleural or pericardial effusion, local high attenuation centrally in the pulmonary arteries and lung infarction occurred respectively. Conclusion: MSCTPA may be an effective, simple and safe technique for the diagnosis of PE. It was a reliable means in defecting PE However, for the cases unfit for contrast media and cases only suitable for unenhanced CT because of nonspecific heart-pulmonary symptom, noticeable abnormal signs of plain MSCT scanning could suggest the occurrence of pulmonary embolism. (authors)

  12. Cardiac imaging using 256-detector row four-dimensional CT. Preliminary clinical report

    International Nuclear Information System (INIS)

    Kido, Teruhito; Kurata, Akira; Higashino, Hiroshi

    2007-01-01

    Along with the increase of detector rows on the z-axis and a faster gantry rotation speed, the spatial and temporal resolutions of the multislice computed tomography (CT) have been improved for noninvasive coronary artery imaging. We investigated the feasibility of the second specification prototype 256-detector row four-dimensional CT for assessing coronary artery and cardiac function. The subjects were five patients with coronary artery disease. Contrast medium (40-60 ml) was intravenously administered at the rate of 3-4 ml/s. The patient's whole heart was scanned for 1.5 s to cover at least one cardiac cycle during breathholding without electrocardiographic gating. Parameters used were 0.5 mm slice thickness, 0.5 s/rotation, 120 Kv, and 350 mA, with a half-scan reconstruction algorithm (temporal resolution 250 ms). Twenty-six transaxial datasets were reconstructed at intervals of 50 ms. The assessability of the coronary arteries in American Heart Association (AHA) segments 1, 2, 3, 5, 6, 7, 9, and 11 was visually evaluated, resulting in 29 of 32 (90.9%) segments being assessable. Functional assessment was also performed using animated movies without banding artifacts in all cases. The 256-detector row four-dimensional CT can assess the coronary artery and cardiac function using data during 1.5 s without banding artifacts. (author)

  13. Crop Row Detection in Maize Fields Inspired on the Human Visual Perception

    Directory of Open Access Journals (Sweden)

    J. Romeo

    2012-01-01

    Full Text Available This paper proposes a new method, oriented to image real-time processing, for identifying crop rows in maize fields in the images. The vision system is designed to be installed onboard a mobile agricultural vehicle, that is, submitted to gyros, vibrations, and undesired movements. The images are captured under image perspective, being affected by the above undesired effects. The image processing consists of two main processes: image segmentation and crop row detection. The first one applies a threshold to separate green plants or pixels (crops and weeds from the rest (soil, stones, and others. It is based on a fuzzy clustering process, which allows obtaining the threshold to be applied during the normal operation process. The crop row detection applies a method based on image perspective projection that searches for maximum accumulation of segmented green pixels along straight alignments. They determine the expected crop lines in the images. The method is robust enough to work under the above-mentioned undesired effects. It is favorably compared against the well-tested Hough transformation for line detection.

  14. Effect of Incident Rainfall Redistribution by Maize Canopy on Soil Moisture at the Crop Row Scale

    Directory of Open Access Journals (Sweden)

    Marco Martello

    2015-05-01

    Full Text Available The optimization of irrigation use in agriculture is a key challenge to increase farm profitability and reduce its ecological footprint. To this context, an understanding of more efficient irrigation systems includes the assessment of water redistribution at the microscale. This study aimed to investigate rainfall interception by maize canopy and to model the soil water dynamics at row scale as a result of rain and sprinkler irrigation with HYDRUS 2D/3D. On average, 78% of rainfall below the maize canopy was intercepted by the leaves and transferred along the stem (stemflow, while only 22% reached the ground directly (throughfall. In addition, redistribution of the water with respect to the amount (both rain and irrigation showed that the stemflow/throughfall ratio decreased logarithmically at increasing values of incident rainfall, suggesting the plant capacity to confine the water close to the roots and diminish water stress conditions. This was also underlined by higher soil moisture values observed in the row than in the inter-row at decreasing rainfall events. Modelled data highlighted different behavior in terms of soil water dynamics between simulated irrigation water distributions, although they did not show significant changes in terms of crop water use efficiency. These results were most likely affected by the soil type (silty-loam where the experiment was conducted, as it had unfavorable physical conditions for the rapid vertical water movement that would have increased infiltration and drainage.

  15. COMPARISON OF ROWING ON A CONCEPT 2 STATIONARY AND DYNAMIC ERGOMETER

    Directory of Open Access Journals (Sweden)

    Aaron Benson

    2011-06-01

    Full Text Available Biomechanical and physiological responses to rowing 1000 m at a power output equivalent to a 2000 m race were compared in 34 collegiate rowers (17 women, 17 men rowing on a stationary and dynamic Concept 2 ergometer. Stroke ratio, peak handle force, rate of force development, impulse, and respiratory exchange ratio decreased by 15.7, 14.8, 10.9, 10.2 and 1.9%, respectively, on the dynamic ergometer. In contrast, percent time to peak force and stroke rate increased by 10.5 and 12.6%, respectively, during dynamic ergometry; the changes in stroke rate and impulse were greater for men than women. Last, VO2 was 5.1% higher and efficiency 5. 3% lower on the dynamic ergometer for men. Collegiate rowers used higher stoke rates and lower peak stroke forces to achieve a similar power output while rowing at race pace on the dynamic ergometer, which may have increased the cardiopulmonary demand and possibly reduced force production in the primary movers. Differences were more pronounced in males than females; this dichotomy may be more due to dynamic ergometer familiarity than sex

  16. Increased foot-stretcher height improves rowing performance: evidence from biomechanical perspectives on water.

    Science.gov (United States)

    Liu, Yang; Gao, Binghong; Li, Jiru; Ma, Zuchang; Sun, Yining

    2018-06-07

    The aim of this study was to investigate whether changes on foot-stretcher height were associated with characteristics of better rowing performance. Ten male rowers performed a 200 m rowing trial at their racing rate at each of three foot-stretcher heights. A single scull was equipped with an accelerometer to collect boat acceleration, an impeller with embedded magnets to collect boat speed, specially designed gate sensors to collect gate force and angle, and a compact string potentiometer to collect leg drive length. All sensor signals were sampled at 50 Hz. A one-way repeated measures ANOVA showed that raising foot-stretcher position had a significant reduction on total gate angle and leg drive length. However, a raised foot-stretcher position had a deeper negative peak of boat acceleration at the catch, a lower boat fluctuation, a faster leg drive speed, a larger gate force for the port and starboard side separately. This could be attributed to the optimisation of the magnitude and direction of the foot force with a raised foot-stretcher position. Although there was a significant negative influence of a raised foot-stretcher position on two kinematic variables, biomechanical evidence suggested that a raised foot-stretcher position could contribute to the improvement of rowing performance.

  17. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors.

    Science.gov (United States)

    Barber, F Alan; Drew, Otis R

    2012-09-01

    To compare tendon-bone interface motion and cyclic loading in a single-row, triple-loaded anchor repair with a suture-tape, rip-stop, double-row rotator cuff repair. Using 18 human shoulders from 9 matched cadaveric pairs, we created 2 groups of rotator cuff repairs. Group 1 was a double-row, rip-stop, suture-tape construct. Group 2 was a single-row, triple-loaded construct. Before mechanical testing, the supraspinatus footprint was measured with calipers. A superiorly positioned digital camera optically measured the tendon footprint motion during 60° of humeral internal and external rotation. Specimens were secured at a fixed angle not exceeding 45° in reference to the load. After preloading, each sample was cycled between 10 N and 100 N for 200 cycles at 1 Hz, followed by destructive testing at 33 mm/s. A digital camera with tracking software measured the repair displacement at 100 and 200 cycles. Ultimate load and failure mode for each sample were recorded. The exposed anterior footprint border (6.5% ± 6%) and posterior footprint border (0.9% ± 1.7%) in group 1 were statistically less than the exposed anterior footprint border (30.3% ± 17%) and posterior footprint border (29.8% ± 14%) in group 2 (P = .003 and P row rotator cuff repair had greater footprint coverage, less rotational footprint displacement, and a greater mean ultimate failure load than the triple-loaded, single-row repair on mechanical testing. No double-row or single-row constructs showed 5 mm of displacement after the first 100 cycles. The most common failure mode for both constructs was suture tearing through the tendon. Differences in cuff fixation influence rotational tendon movement and may influence postoperative healing. Stronger repair constructs still fail at the suture-tendon interface. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  18. Ultrasound evaluation of arthroscopic full-thickness supraspinatus rotator cuff repair: single-row versus double-row suture bridge (transosseous equivalent) fixation. Results of a prospective, randomized study.

    Science.gov (United States)

    Gartsman, Gary M; Drake, Gregory; Edwards, T Bradley; Elkousy, Hussein A; Hammerman, Steven M; O'Connor, Daniel P; Press, Cyrus M

    2013-11-01

    The purpose of this study was to compare the structural outcomes of a single-row rotator cuff repair and double-row suture bridge fixation after arthroscopic repair of a full-thickness supraspinatus rotator cuff tear. We evaluated with diagnostic ultrasound a consecutive series of ninety shoulders in ninety patients with full-thickness supraspinatus tears at an average of 10 months (range, 6-12) after operation. A single surgeon at a single hospital performed the repairs. Inclusion criteria were full-thickness supraspinatus tears less than 25 mm in their anterior to posterior dimension. Exclusion criteria were prior operations on the shoulder, partial thickness tears, subscapularis tears, infraspinatus tears, combined supraspinatus and infraspinatus repairs and irreparable supraspinatus tears. Forty-three shoulders were repaired with single-row technique and 47 shoulders with double-row suture bridge technique. Postoperative rehabilitation was identical for both groups. Ultrasound criteria for healed repair included visualization of a tendon with normal thickness and length, and a negative compression test. Eighty-three patients were available for ultrasound examination (40 single-row and 43 suture-bridge). Thirty of 40 patients (75%) with single-row repair demonstrated a healed rotator cuff repair compared to 40/43 (93%) patients with suture-bridge repair (P = .024). Arthroscopic double-row suture bridge repair (transosseous equivalent) of an isolated supraspinatus rotator cuff tear resulted in a significantly higher tendon healing rate (as determined by ultrasound examination) when compared to arthroscopic single-row repair. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  19. Microjet flow control in an ultra-compact serpentine inlet

    Directory of Open Access Journals (Sweden)

    Da Xingya

    2015-10-01

    Full Text Available Microjets are used to control the internal flow to improve the performance of an ultra-compact serpentine inlet. A highly offset serpentine inlet with length-to-diameter ratio of 2.5 is designed and static tests are conducted to analyze the internal flow characteristics in terms of pressure recovery, distortion and flow separation. Flow separation is encountered in the second S-turn, and two strong counter-rotating vortices are formed at the aerodynamic interface plane (AIP face which occupy a quarter of the outlet area and result in severe pressure loss and distortion. A flow control model employing a row of microjets in the second turn is designed based on the internal flow characteristics and simplified CFD simulations. Flow control tests are conducted to verify the control effectiveness and understand the characteristics as a function of inlet throat Mach number, injection mass flow ratio, jet Mach number and momentum coefficient. At all test Mach numbers, microjet flow control (MFC effectively improves the recovery and reduces the distortion intensity. Between inlet throat Mach number 0.2 and 0.5, the strong flow separation in the second S-turn is suppressed at an optimum jet flow ratio of less than 0.65%, resulting in a maximum improvement of 4% for pressure recovery coefficient and a maximum decrease of 75% for circumferential distortion intensity at cruise. However, in order to suppress the flow separation, the injection rate should retain in an effective range. When the injection rate is higher than this range, the flow is degraded and the distortion contour is changed from 90° circumferential distortion pattern to 180° circumferential distortion pattern. Detailed data analysis shows that this optimum flow ratio depends on inlet throat Mach number and the momentum coefficient affects the control effectiveness in a dual stepping manner.

  20. The Effect of Concurrent Plyometric Training Versus Submaximal Aerobic Cycling on Rowing Economy, Peak Power, and Performance in Male High School Rowers.

    Science.gov (United States)

    Egan-Shuttler, Julian D; Edmonds, Rohan; Eddy, Cassandra; O'Neill, Veronica; Ives, Stephen J

    2017-12-01

    Plyometric training has been shown to increase muscle power, running economy, and performance in athletes. Despite its use by rowing coaches, it is unknown whether plyometrics might improve rowing economy or performance. The purpose was to determine if plyometric training, in conjunction with training on the water, would lead to improved rowing economy and performance. Eighteen male high school rowers were assigned to perform 4 weeks of either plyometric training (PLYO, n = 9) or steady-state cycling below ventilatory threshold (endurance, E, n = 9), for 30 min prior to practice on the water (matched for training volume) 3 days per week. Rowing performance was assessed through a 500-m rowing time trial (TT) and peak rowing power (RP), while rowing economy (RE) was assessed by measuring the oxygen cost over four work rates (90, 120, 150, and 180 W). Rowing economy was improved in both PLYO and E (p  0.05). Finally, RP was moderately higher in the PLYO group post-training (E 569 ± 75 W, PLYO 629 ± 51 W, ES = 0.66) CONCLUSIONS: In a season when the athletes performed no rowing sprint training, 4 weeks of plyometric training improved the 500-m rowing performance and moderately improved peak power. This increase in performance may have been mediated by moderate improvements in rowing power, but not economy, and warrants further investigation.

  1. Tolerância da soja ao desfolhamento afetada pela redução do espaçamento entre fileiras Soybean tolerance to defoliation as affected by row spacing reduction

    Directory of Open Access Journals (Sweden)

    Geovano Parcianello

    2004-04-01

    three stages of development (V9 - ninth-node, R2 - full bloom and R5 - beginning of seed filling, two row spacings (20 and 40cm and four defoliation levels (0 - control, 33, 67 and 100%. The cultivar tested was FT-Abyara. Defoliations performed at the reproductive stages decrease grain yield, especially when curried at the begging of grain filling (R5. The control grain yield was 21% higher when soybean was sown with rows 20cm apart (4134kg ha-1 than with 40cm rows (3413kg ha-1. Narrow rows always provided higher yields in all defoliation levels. The component that influenced yield the most was the number of pods m-2. These results indicate that row spacing reduction from 40cm to 20cm is a positive management strategy for soybean production regardless of defoliation level.

  2. Knotless double-row SutureBridge rotator cuff repairs have improved self-reinforcement compared with double-row SutureBridge repairs with tied medial knots: a biomechanical study using an ovine model.

    Science.gov (United States)

    Smith, Geoffrey C S; Bouwmeester, Theresia M; Lam, Patrick H

    2017-12-01

    In double-row SutureBridge (Arthrex, Naples, FL, USA) rotator cuff repairs, increasing tendon load may generate progressively greater compression forces at the repair footprint (self-reinforcement). SutureBridge rotator cuff repairs using tied horizontal mattress sutures medially may limit this effect compared with a knotless construct. Rotator cuff repairs were performed in 9 pairs of ovine shoulders. One group underwent repair with a double-row SutureBridge construct with tied horizontal medial-row mattress sutures. The other group underwent repair in an identical fashion except that medial-row knots were not tied. Footprint contact pressure was measured at 0° and 20° of abduction under loads of 0 to 60 N. Pull-to-failure tests were then performed. In both repair constructs, each 10-N increase in rotator cuff tensile load led to a significant increase in footprint contact pressure (P row SutureBridge configuration, self-reinforcement is seen in repairs with and without medial-row knots. Self-reinforcement is greater with the knotless technique. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. Self-organization of S adatoms on Au(111): √3R30° rows at low coverage.

    Science.gov (United States)

    Walen, Holly; Liu, Da-Jiang; Oh, Junepyo; Lim, Hyunseob; Evans, J W; Kim, Yousoo; Thiel, P A

    2015-07-07

    Using scanning tunneling microscopy, we observe an adlayer structure that is dominated by short rows of S atoms, on unreconstructed regions of a Au(111) surface. This structure forms upon adsorption of low S coverage (less than 0.1 monolayer) on a fully reconstructed clean surface at 300 K, then cooling to 5 K for observation. The rows adopt one of three orientations that are rotated by 30° from the close-packed directions of the Au(111) substrate, and adjacent S atoms in the rows are separated by √3 times the surface lattice constant, a. Monte Carlo simulations are performed on lattice-gas models, derived using a limited cluster expansion based on density functional theory energetics. Models which include long-range pairwise interactions (extending to 5a), plus selected trio interactions, successfully reproduce the linear rows of S atoms at reasonable temperatures.

  4. Transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears.

    Science.gov (United States)

    Dilisio, Matthew F; Miller, Lindsay R; Higgins, Laurence D

    2014-10-01

    Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness.

  5. Self-organization of S adatoms on Au(111): √3R30° rows at low coverage

    Energy Technology Data Exchange (ETDEWEB)

    Walen, Holly, E-mail: hwalen@iastate.edu [Department of Chemistry, Iowa State University, Ames, Iowa 50011 (United States); Liu, Da-Jiang [Ames Laboratory of the USDOE, Ames, Iowa 50011 (United States); Oh, Junepyo; Lim, Hyunseob; Kim, Yousoo [RIKEN Surface and Interface Science Laboratory, Wako, Saitama 351-0198 (Japan); Evans, J. W. [Ames Laboratory of the USDOE, Ames, Iowa 50011 (United States); Department of Physics and Astronomy, Iowa State University, Ames, Iowa 50011 (United States); Thiel, P. A. [Department of Chemistry, Iowa State University, Ames, Iowa 50011 (United States); Ames Laboratory of the USDOE, Ames, Iowa 50011 (United States); Department of Materials Science and Engineering, Iowa State University, Ames, Iowa 50011 (United States)

    2015-07-07

    Using scanning tunneling microscopy, we observe an adlayer structure that is dominated by short rows of S atoms, on unreconstructed regions of a Au(111) surface. This structure forms upon adsorption of low S coverage (less than 0.1 monolayer) on a fully reconstructed clean surface at 300 K, then cooling to 5 K for observation. The rows adopt one of three orientations that are rotated by 30° from the close-packed directions of the Au(111) substrate, and adjacent S atoms in the rows are separated by √3 times the surface lattice constant, a. Monte Carlo simulations are performed on lattice-gas models, derived using a limited cluster expansion based on density functional theory energetics. Models which include long-range pairwise interactions (extending to 5a), plus selected trio interactions, successfully reproduce the linear rows of S atoms at reasonable temperatures.

  6. Medial versus lateral supraspinatus tendon properties: implications for double-row rotator cuff repair.

    Science.gov (United States)

    Wang, Vincent M; Wang, Fan Chia; McNickle, Allison G; Friel, Nicole A; Yanke, Adam B; Chubinskaya, Susan; Romeo, Anthony A; Verma, Nikhil N; Cole, Brian J

    2010-12-01

    Rotator cuff repair retear rates range from 25% to 90%, necessitating methods to improve repair strength. Although numerous laboratory studies have compared single-row with double-row fixation properties, little is known regarding regional (ie, medial vs lateral) suture retention properties in intact and torn tendons. A torn supraspinatus tendon will have reduced suture retention properties on the lateral aspect of the tendon compared with the more medial musculotendinous junction. Controlled laboratory study. Human supraspinatus tendons (torn and intact) were randomly assigned for suture retention mechanical testing, ultrastructural collagen fibril analysis, or histologic testing after suture pullout testing. For biomechanical evaluation, sutures were placed either at the musculotendinous junction (medial) or 10 mm from the free margin (lateral), and tendons were elongated to failure. Collagen fibril assessments were performed using transmission electron microscopy. Intact tendons showed no regional differences with respect to suture retention properties. In contrast, among torn tendons, the medial region exhibited significantly higher stiffness and work values relative to the lateral region. For the lateral region, work to 10-mm displacement (1592 ± 261 N-mm) and maximum load (265 ± 44 N) for intact tendons were significantly higher (P .05). Regression analyses for the intact and torn groups revealed generally low correlations between donor age and the 3 biomechanical indices. For both intact and torn tendons, the mean fibril diameter and area density were greater in the medial region relative to the lateral (P ≤ .05). In the lateral tendon, but not the medial region, torn specimens showed a significantly lower fibril area fraction (48.3% ± 3.8%) than intact specimens (56.7% ± 3.6%, P row after double-row repair. Larger diameter collagen fibrils as well as greater fibril area fraction in the medial supraspinatus tendon may provide greater resistance to

  7. Impact of Inter-Row Spacing on Yield and Yield Components of several Annual Medics Species

    Directory of Open Access Journals (Sweden)

    Mahnaz BAGHERI

    2010-12-01

    Full Text Available A field study was conducted in Faculty of Agriculture, Tarbiat Modares University, Tehran, Iran to evaluate the effects of three within-row spacing treatments (20, 30 and 40 cm on forage and seed production of five species of annual medics (Medicago scutellata cv. Sava; M. littoralis cv. Herald; M. polymorpha cv. Santiago; M. minima cv. Orion and M. truncatula cv. Mogul. The experiment was carried out in Faculty of Agriculture, Tarbiat Modares University, Tehran, Iran. The results of the experiment indicated that M. polymorpha had the highest forage yield out of the highest plant population. Latter with average 443.09 Kg ha-1 and M. scutellata with average 409.99 Kg ha-1 produced the highest seed yield. Also, the last species with 1306.78 Kg ha-1 had the highest pod yields. The highest seed yield and pod yield were produced at 20 cm within-row spacing because there were not adequate plants for maximum seed and pod yields in 30 and 40 cm within-row spacing. The tested plant densities did not affect on seeds number per pod, 1000 seeds weight and seeds to burr pod weight ratio. The M. truncatula and M. minima have the highest seeds number per pod. In addition, M. scutellata had the highest 1000 seeds weight with an average of 12.57 g. The highest seeds to burr pod ratio was observed in M. polymorpha. The most pod numbers were obtained in 20 and 30 cm within-row spacing and M. polymorpha while, the least pod numbers was observed in M. scutellata. Plant densities did not affect on pod numbers of the mentioned species. The highest dry forage yield was produced in 20 cm within-row spacing. Among the tested tested species, M. truncatula had the highest forage yield with average 870.07 Kg ha-1. This experiment indicated that there is possibility for seed and forage production of tested annual medics in the mentioned zone with the considering suitable plant densities.

  8. Narrow power deposition profiles on the JET divertor target

    International Nuclear Information System (INIS)

    Lingertat, J.; Laux, M.; Monk, R.

    2001-01-01

    One of the key unresolved issues in the design of a future fusion reactor is the power handling capability of the divertor target plates. Earlier we reported on the existence of narrow power deposition profiles in JET, obtained mainly from Langmuir probe measurements. We repeated these measurements in the MkI, MkII and MkIIGB divertor configurations with an upgraded probe system, which allowed us to study the profile shape in more detail. The main results of this study are: In NB heated discharges the electron temperature and power flux at the outer target show a distinct peak of ∼5 mm half-width near the separatrix strike point. The corresponding profiles on the inner target do not show a similar feature. The height of the narrow peak increases with NB heating power and decreases with deuterium and impurity gas puffing. Ion orbit losses are suggested as a possible explanation of the observed profile shape

  9. Experimental research on flow instability in vertical narrow annuli

    Institute of Scientific and Technical Information of China (English)

    WU Geping; QIU Suizheng; SU Guanghui; JIA Dounan

    2007-01-01

    A narrow annular test section of 1.5mm gap and 1800mm length was designed and manufactured, with good tightness and insulation. Experiments were carried out to investigate characteristics of flow instability of forced-convection in vertical narrow annuli. Using distilled water as work fluid, the experiments were conducted at pressures of 1.0~3.0 MPa, mass flow rates of 3.0~25 kg/h, heating power of 3.0~ 6.5kW and inlet fluid temperature of 20 ℃, 40 ℃ or 60℃. It was found that flow instability occured with fixed inlet condition and heating power when mass flow rate was below a special value. Effects of inlet subcooling, system pressure and mass flow rate on the system behavior were studied and the instability region was given.

  10. Coulomb and nuclear excitations of narrow resonances in 17Ne

    Directory of Open Access Journals (Sweden)

    J. Marganiec

    2016-08-01

    Full Text Available New experimental data for dissociation of relativistic 17Ne projectiles incident on targets of lead, carbon, and polyethylene targets at GSI are presented. Special attention is paid to the excitation and decay of narrow resonant states in 17Ne. Distributions of internal energy in the O15+p+p three-body system have been determined together with angular and partial-energy correlations between the decay products in different energy regions. The analysis was done using existing experimental data on 17Ne and its mirror nucleus 17N. The isobaric multiplet mass equation is used for assignment of observed resonances and their spins and parities. A combination of data from the heavy and light targets yielded cross sections and transition probabilities for the Coulomb excitations of the narrow resonant states. The resulting transition probabilities provide information relevant for a better understanding of the 17Ne structure.

  11. Period effects, cohort effects, and the narrowing gender wage gap.

    Science.gov (United States)

    Campbell, Colin; Pearlman, Jessica

    2013-11-01

    Despite the abundance of sociological research on the gender wage gap, questions remain. In particular, the role of cohorts is under investigated. Using data from the Current Population Survey, we use age-period-cohort analysis to uniquely estimate age, period, and cohort effects on the gender wage gap. The narrowing of the gender wage gap that occurred between 1975 and 2009 is largely due to cohort effects. Since the mid-1990s, the gender wage gap has continued to close absent of period effects. While gains in female wages contributed to declines in the gender wage gap for cohorts born before 1950, for later cohorts the narrowing of the gender wage gap is primarily a result of declines in male wages. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Experimental Study on CHF in a Hemispherical Narrow Gap

    International Nuclear Information System (INIS)

    Jeong, J.H.; Park, R.J.; Kang, K.H.; Kim, S.B.; Kim, H.D.

    1999-01-01

    As a part of the SONATA-IV program, KAERI is conducting an experimental investigation of critical heat flux(CHF) in hemispherical narrow gaps. A visualization experiment, VISU-II, was done as the first step to get a visual observation of the flow behaviour inside a hemispherical gap and to understand the CHF-triggering mechanism. It was observed that the counter-current flow limitation (CCFL) phenomenon prevented water from wetting the heater surface and induced CHF. The CHFG (Critical Heat Flux in Gap) test is now being performed to measure the CHF and to investigate the inherent cooling mechanism in hemispherical narrow gaps. Temperature measurements over the heater surface show that the two-phase flow behaviour inside the gaps could be quite different from the other usual CHF experiments. The measured CHF points are lower than the predictions by existing empirical correlations based on the data measured with small-scale horizontal plates and vertical annulus. (authors)

  13. Period Effects, Cohort Effects, and the Narrowing Gender Wage Gap

    Science.gov (United States)

    Campbell, Colin; Pearlman, Jessica

    2015-01-01

    Despite the abundance of sociological research on the gender wage gap, questions remain. In particular, the role of cohorts is under investigated. Using data from the Current Population Survey, we use Age-Period-Cohort analysis to uniquely estimate age, period, and cohort effects on the gender wage gap. The narrowing of the gender wage gap that occurred between 1975 and 2009 is largely due to cohort effects. Since the mid-1990s, the gender wage gap has continued to close absent of period effects. While gains in female wages contributed to declines in the gender wage gap for cohorts born before 1950, for later cohorts the narrowing of the gender wage gap is primarily a result of declines in male wages. PMID:24090861

  14. Transtendon, Double-Row, Transosseous-Equivalent Arthroscopic Repair of Partial-Thickness, Articular-Surface Rotator Cuff Tears

    OpenAIRE

    Dilisio, Matthew F.; Miller, Lindsay R.; Higgins, Laurence D.

    2014-01-01

    Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-s...

  15. A biomechanical comparison of 2 transosseous-equivalent double-row rotator cuff repair techniques using bioabsorbable anchors: cyclic loading and failure behavior.

    Science.gov (United States)

    Spang, Jeffrey T; Buchmann, Stefan; Brucker, Peter U; Kouloumentas, Panos; Obst, Tobias; Schröder, Manuel; Burgkart, Rainer; Imhoff, Andreas B

    2009-08-01

    A novel double-row configuration was compared with a traditional double-row configuration for rotator cuff repair. In 10 matched-pair sheep shoulders in vitro repair was performed with either a double-row technique with corkscrew suture anchors for the medial row and insertion anchors for the lateral row (group A) or a double-row technique with a new tape-like suture material with insertion anchors for both the medial and lateral rows (group B). Each specimen underwent cyclic loading from 10 to 150 N for 100 cycles, followed by unidirectional failure testing. Gap formation and strain within the repair area for the first and last cycles were analyzed with a video digitizing system, and stiffness and failure load were determined from the load-elongation curve. The results were similar for the 2 repair types. There was no significant difference between the ultimate failure loads of the 2 techniques (421 +/- 150 N in group A and 408 +/- 66 N in group B, P = .31) or the stiffness of the 2 techniques (84 +/- 26 N/mm in group A and 99 +/- 20 N/mm in group B, P = .07). In addition, gap formation was not different between the repair types. Strain over the repair area was also not different between the repair types. Both tested rotator cuff repair techniques had high failure loads, limited gap formation, and acceptable strain patterns. No significant difference was found between the novel and conventional double-row repair types. Two double-row techniques-one with corkscrew suture anchors for the medial row and insertion anchors for the lateral row and one with insertion anchors for both the medial and lateral rows-provided excellent biomechanical profiles at time 0 for double-row repairs in a sheep model. Although the sheep model may not directly correspond to in vivo conditions, all-insertion anchor double-row constructs are worthy of further investigation.

  16. New technology for the control of narrow-gap semiconductors

    International Nuclear Information System (INIS)

    Antoniou, I.; Bozhevolnov, V.; Melnikov, Yu.; Yafyasov, A.

    2003-01-01

    We present the results of the year work in the frame of the EU ESPRIT Project 28890 NTCONGS 'New technology for the control of narrow-gap semiconductors'. This work has involved both theoretical and experimental study, as well as the development of new specific equipment, towards the creation of a new generation of nanoelectronic devices able to operate at 77 K and even at room temperature

  17. US images encoding envelope amplitude following narrow band filtering

    International Nuclear Information System (INIS)

    Sommer, F.G.; Stern, R.A.; Chen, H.S.

    1986-01-01

    Ultrasonic waveform data from phantoms having differing scattering characteristics and from normal and cirrhotic human liver in vivo were recorded within a standardized dynamic range and filtered with narrow band filters either above or below the mean recorded ultrasonic center frequency. Images created by mapping the amplitudes of received ultrasound following such filtration permitted dramatic differentiation, not discernible in conventional US images, of phantoms having differing scattering characteristics, and of normal and cirrhotic human livers

  18. Elongational viscosity of narrow molar mass distribution polystyrene

    DEFF Research Database (Denmark)

    Bach, Anders; Almdal, Kristoffer; Rasmussen, Henrik Koblitz

    2003-01-01

    Transient and steady elongational viscosity has been measured for two narrow molar mass distribution polystyrene melts of molar masses 200 000 and 390 000 by means of a filament stretching rheometer. Total Hencky strains of about five have been obtained. The transient elongational viscosity rises...... above the linear viscoelastic prediction at intermediate strains, indicating strain hardening. The steady elongational viscosities are monotone decreasing functions of elongation rate. At elongation rates larger than the inverse reptation time, the steady elongational viscosity scales linearly...

  19. Cervical spinal canal narrowing and cervical neurologi-cal injuries

    Directory of Open Access Journals (Sweden)

    ZHANG Ling

    2012-04-01

    Full Text Available 【Abstract】Cervical spinal canal narrowing can lead to injury of the spinal cord and neurological symptoms in-cluding neck pain, headache, weakness and parasthesisas. According to previous and recent clinical researches, we investigated the geometric parameters of normal cervical spinal canal including the sagittal and transverse diameters as well as Torg ratio. The mean sagittal diameter of cervical spinal canal at C 1 to C 7 ranges from 15.33 mm to 20.46 mm, the mean transverse diameter at the same levels ranges from 24.45 mm to 27.00 mm and the mean value of Torg ratio is 0.96. With respect to narrow cervical spinal canal, the following charaterstics are found: firstly, extension of the cervical spine results in statistically significant stenosis as compared with the flexed or neutral positions; secondly, females sustain cervical spinal canal narrowing more easily than males; finally, the consistent narrowest cervical canal level is at C 4 for all ethnicity, but there is a slight variation in the sagittal diameter of cervical spinal stenosis (≤14 mm in Whites, ≤ 12 mm in Japanese, ≤13.7 mm in Chinese. Narrow sagittal cervical canal diameter brings about an increased risk of neurological injuries in traumatic, degenerative and inflam-matory conditions and is related with extension of cervical spine, gender, as well as ethnicity. It is hoped that this re-view will be helpful in diagnosing spinal cord and neuro-logical injuries with the geometric parameters of cervical spine in the future. Key words: Spinal cord injuries; Spinal stenosis; Trauma, nervous system

  20. Generation of narrow peaks in spectroscopy of charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Dubbers, Dirk, E-mail: dubbers@physi.uni-heidelberg.de; Schmidt, Ulrich, E-mail: ulrich.schmidt@physi.uni-heidelberg.de

    2016-11-21

    In spectroscopy of charged particles, narrow peaks may appear in continuous spectra if magnetic transport of the particles is involved. These artefacts, which so far have escaped the attention of investigators, can develop whenever geometric detection efficiency is less than 100%. As such peaks may be misinterpreted as new physics, their generation is investigated, both analytically and experimentally, for various detector configurations, including those used in searches for the spontaneous decay of the vacuum in heavy-ion collisions.

  1. The 1987 Whittier Narrows, California, earthquake: A Metropolitan shock

    OpenAIRE

    Hauksson, Egill; Stein, Ross S.

    1989-01-01

    Just 3 hours after the Whittier Narrows earthquake struck, it became clear that a heretofore unseen geological structure was seismically active beneath metropolitan Los Angeles. Contrary to initial expectations of strike-slip or oblique-slip motion on the Whittier fault, whose north end abuts the aftershock zone, the focal mechanism of the mainshock showed pure thrust faulting on a deep gently inclined surface [Hauksson et al., 1988]. This collection of nine research reports spans the spectru...

  2. Three-Prong Distribution of Massive Narrow QCD Jets

    CERN Document Server

    Field, Matan; Kosower, David A; Mannelli, Lorenzo; Perez, Gilad

    2013-01-01

    We study the planar-flow distributions of narrow, highly boosted, massive QCD jets. Using the factorization properties of QCD in the collinear limit, we compute the planar-flow jet function from the one-to-three splitting function at tree-level. We derive the leading-log behavior of the jet function analytically. We also compare our semi-analytic jet function with parton-shower predictions using various generators.

  3. Present status of heat transfer in narrow gap rectangular channel

    International Nuclear Information System (INIS)

    Sudo, Yukio; Kaminaga, Masanori

    1990-01-01

    In the safety evaluation for research nuclear reactors, at the time of abnormal transient change and accidents, after the tripping of a primary coolant pump, such event that the flow direction of coolant in a core reverses from steady downward flow to rising flow is supposed. In this case, the coexisting convection field, in which free convection and forced convection coexist, arises in place of forced convection, and especially in the research reactors using plate type fuel like JRR-3, it is important to grasp the heat transfer characteristics in the coexisting convection field in a narrow channel. Jackson et al. proposed the heat transfer correlation equation which can be applied to wide conditions including the coexisting convection zone, but its applicability to a narrow channel has not been confirmed. Based on the experimental results, in this study, the effect that the decrease of gap exerts to the convection heat transfer characteristics reported so far was investigated. The experiment and the results are reported. In this experiment on the coexisting convection zone in a narrow gap, the effect of main flow acceleration arose sufficiently large as compared with the effect of buoyancy, and heat transfer was promoted. (K.I.)

  4. Electron correlations in narrow energy bands: modified polar model approach

    Directory of Open Access Journals (Sweden)

    L. Didukh

    2008-09-01

    Full Text Available The electron correlations in narrow energy bands are examined within the framework of the modified form of polar model. This model permits to analyze the effect of strong Coulomb correlation, inter-atomic exchange and correlated hopping of electrons and explain some peculiarities of the properties of narrow-band materials, namely the metal-insulator transition with an increase of temperature, nonlinear concentration dependence of Curie temperature and peculiarities of transport properties of electronic subsystem. Using a variant of generalized Hartree-Fock approximation, the single-electron Green's function and quasi-particle energy spectrum of the model are calculated. Metal-insulator transition with the change of temperature is investigated in a system with correlated hopping. Processes of ferromagnetic ordering stabilization in the system with various forms of electronic DOS are studied. The static conductivity and effective spin-dependent masses of current carriers are calculated as a function of electron concentration at various DOS forms. The correlated hopping is shown to cause the electron-hole asymmetry of transport and ferromagnetic properties of narrow band materials.

  5. Heavy drinking, impulsivity and attentional narrowing following alcohol cue exposure.

    Science.gov (United States)

    Hicks, Joshua A; Fields, Sherecce; Davis, William E; Gable, Philip A

    2015-08-01

    Research shows that alcohol-related stimuli have the propensity to capture attention among individuals motivated to consume alcohol. Research has further demonstrated that impulsive individuals are especially prone to this type of attentional bias. Recently, it is suggested that alcohol cue exposure can also produce a general narrowing of attention consistent with the activation of approach motivational states. Based on previous models of addiction and recent research on the activation of approach motivational states, we predicted that impulsive individuals would demonstrate a constriction of attentional focus in response to alcohol cue exposure. Participants (n = 392) completed a task assessing attentional breadth in response to alcohol and non-alcohol cues, followed by measures of alcohol use and impulsivity. The findings revealed that impulsivity scores predicted narrowing of attentional scope following the presentation of alcohol cues for heavier drinkers but not for light drinkers. These results suggest that impulsive individuals who drink more heavily demonstrate a narrowing of attention in the presence of alcohol-related incentive cues. Implications for how these findings might account for the link between impulsivity and alcohol use and misuse are discussed.

  6. Experimental study on occupant evacuation in narrow seat aisle

    Science.gov (United States)

    Huang, Shenshi; Lu, Shouxiang; Lo, Siuming; Li, Changhai; Guo, Yafei

    2018-07-01

    Narrow seat aisle is an important area in the train car interior due to the large passenger population, however evacuation therein has not gained enough concerns. In this experimental study, the occupant evacuation of the narrow seat aisle area is investigated, with the aisle width of 0.4-0.6 m and the evacuation direction of forward and backward. The evacuation behaviors are analyzed based on the video record, and the discussion is carried out in the aspect of evacuation time, crowdedness, evacuation order, and aisle conflicts. The result shows that with the increasing aisle width, total evacuation time and the average specific evacuation rate decrease. The aisle is crowded for some time, with a large linear occupant densities. The evacuation order of each occupant is mainly related to the seat position. Moreover, it is found that the aisle conflicts can be well described by Burstedde's model. This study gives a useful benchmark for evacuation simulation of narrow seat aisle, and provides reference to safety design of seat area in train cars.

  7. Photonic bandgap narrowing in conical hollow core Bragg fibers

    Energy Technology Data Exchange (ETDEWEB)

    Ozturk, Fahri Emre; Yildirim, Adem; Kanik, Mehmet [UNAM-National Nanotechnology Research Center, Bilkent University, 06800 Ankara (Turkey); Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara (Turkey); Bayindir, Mehmet, E-mail: bayindir@nano.org.tr [UNAM-National Nanotechnology Research Center, Bilkent University, 06800 Ankara (Turkey); Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara (Turkey); Department of Physics, Bilkent University, 06800 Ankara (Turkey)

    2014-08-18

    We report the photonic bandgap engineering of Bragg fibers by controlling the thickness profile of the fiber during the thermal drawing. Conical hollow core Bragg fibers were produced by thermal drawing under a rapidly alternating load, which was applied by introducing steep changes to the fiber drawing speed. In conventional cylindrical Bragg fibers, light is guided by omnidirectional reflections from interior dielectric mirrors with a single quarter wave stack period. In conical fibers, the diameter reduction introduced a gradient of the quarter wave stack period along the length of the fiber. Therefore, the light guided within the fiber encountered slightly smaller dielectric layer thicknesses at each reflection, resulting in a progressive blueshift of the reflectance spectrum. As the reflectance spectrum shifts, longer wavelengths of the initial bandgap cease to be omnidirectionally reflected and exit through the cladding, which narrows the photonic bandgap. A narrow transmission bandwidth is particularly desirable in hollow waveguide mid-infrared sensing schemes, where broadband light is coupled to the fiber and the analyte vapor is introduced into the hollow core to measure infrared absorption. We carried out sensing simulations using the absorption spectrum of isopropyl alcohol vapor to demonstrate the importance of narrow bandgap fibers in chemical sensing applications.

  8. Novel structural flexibility identification in narrow frequency bands

    International Nuclear Information System (INIS)

    Zhang, J; Moon, F L

    2012-01-01

    A ‘Sub-PolyMAX’ method is proposed in this paper not only for estimating modal parameters, but also for identifying structural flexibility by processing the impact test data in narrow frequency bands. The traditional PolyMAX method obtains denominator polynomial coefficients by minimizing the least square (LS) errors of frequency response function (FRF) estimates over the whole frequency range, but FRF peaks in different structural modes may have different levels of magnitude, which leads to the modal parameters identified for the modes with small FRF peaks being inaccurate. In contrast, the proposed Sub-PolyMAX method implements the LS solver in each subspace of the whole frequency range separately; thus the results identified from a narrow frequency band are not affected by FRF data in other frequency bands. In performing structural identification in narrow frequency bands, not in the whole frequency space, the proposed method has the following merits: (1) it produces accurate modal parameters, even for the modes with very small FRF peaks; (2) it significantly reduces computation cost by reducing the number of frequency lines and the model order in each LS implementation; (3) it accurately identifies structural flexibility from impact test data, from which structural deflection under any static load can be predicted. Numerical and laboratory examples are investigated to verify the effectiveness of the proposed method. (paper)

  9. Joint Space Narrowing in Patients With Pisotriquetral Osteoarthritis.

    Science.gov (United States)

    Ten Berg, Paul W L; Heeg, Erik; Strackee, Simon D; Streekstra, Geert J

    2017-09-01

    Patients with suspected pisotriquetral osteoarthritis may show joint space narrowing. However, the extent of joint space narrowing and its deviation from the joint space width (JSW) in normal anatomy is unknown. In this pathoanatomic study, we therefore compared the JSW in the pisotriquetral joint between osteoarthritic patient wrists and healthy wrists. We reviewed preoperative computed tomography (CT) scans of 8 wrists of patients with ulnar-sided wrist pain who underwent a pisiformectomy with confirmed pisotriquetral osteoarthritis at surgery. We also reviewed CT scans of 20 normal wrists from healthy volunteers serving as control group. Three-dimensional CT models of the pisiform and triquetrum were obtained from both affected and normal wrists, after which the minimum JSW was calculated in an automated fashion. In the patient group, the median (interquartile range) of the minimum JSW was 0.1 mm (0.0-0.2), and in the control group, 0.8 mm (0.3-0.9) ( P = .007). We showed that the pisotriquetral joint space in osteoarthritic patient wrists was significantly narrowed compared with healthy wrists. These results suggest that JSW evaluation has a potential diagnostic value in the work-up of patients with suspected pisotriquetral osteoarthritis. This is an interesting area for future clinical research, especially because no gold standard for diagnosing pisotriquetral osteoarthritis has been established yet.

  10. High prevalence of narrow angles among Filipino-American patients.

    Science.gov (United States)

    Seider, Michael I; Sáles, Christopher S; Lee, Roland Y; Agadzi, Anthony K; Porco, Travis C; Weinreb, Robert N; Lin, Shan C

    2011-03-01

    To determine the prevalence of gonioscopically narrow anterior chamber angles in a Filipino-American clinic population. The records of 122 consecutive, new, self-declared Filipino-American patients examined in a comprehensive ophthalmology clinic in Vallejo, California were reviewed retrospectively. After exclusion, 222 eyes from 112 patients remained for analysis. Data were collected for anterior chamber angle grade as determined by gonioscopy (Shaffer system), age, sex, manifest refraction (spherical equivalent), intraocular pressure, and cup-to-disk ratio. Data from both eyes of patients were included and modeled using standard linear mixed-effects regression. As a comparison, data were also collected from a group of 30 consecutive White patients from the same clinic. After exclusion, 50 eyes from 25 White patients remained for comparison. At least 1 eye of 24% of Filipino-American patients had a narrow anterior chamber angle (Shaffer grade ≤ 2). Filipino-American angle grade significantly decreased with increasingly hyperopic refraction (P=0.007) and larger cup-to-disk ratio (P=0.038). Filipino-American women had significantly decreased angle grades compared with men (P=0.028), but angle grade did not vary by intraocular pressure or age (all, P≥ 0.059). Narrow anterior chamber angles are highly prevalent in Filipino-American patients in our clinic population.

  11. Ultra-cold molecule production

    International Nuclear Information System (INIS)

    Ramirez-Serrano, Jamie; Chandler, David W.; Strecker, Kevin; Rahn, Larry A.

    2005-01-01

    The production of Ultra-cold molecules is a goal of many laboratories through out the world. Here we are pursuing a unique technique that utilizes the kinematics of atomic and molecular collisions to achieve the goal of producing substantial numbers of sub Kelvin molecules confined in a trap. Here a trap is defined as an apparatus that spatially localizes, in a known location in the laboratory, a sample of molecules whose temperature is below one degree absolute Kelvin. Further, the storage time for the molecules must be sufficient to measure and possibly further cool the molecules. We utilize a technique unique to Sandia to form cold molecules from near mass degenerate collisions between atoms and molecules. This report describes the progress we have made using this novel technique and the further progress towards trapping molecules we have cooled

  12. Ultra high energy gamma-ray astronomy

    International Nuclear Information System (INIS)

    Wdowczyk, J.

    1986-01-01

    The experimental data on ultra high energy γ-rays are reviewed and a comparison of the properties of photon and proton initiated shower is made. The consequences of the existence of the strong ultra high energy γ-ray sources for other observations is analysed and possible mechanisms for the production of ultra high energy γ-rays in the sources are discussed. It is demonstrated that if the γ-rays are produced via cosmic ray interactions the sources have to produce very high fluxes of cosmic ray particles. In fact it is possible that a small number of such sources can supply the whole Galactic cosmic ray flux

  13. Ultras in Trnava: History, Activities and Ideology

    Directory of Open Access Journals (Sweden)

    Kušnierová Daniela

    2014-12-01

    Full Text Available The environment of football fans is unknown phenomenon for the rest of the public. This article offers basic view on formation and functioning of the most numerous and the most active ultras group in Slovakia, Trnava fans. First part of the text encompasses a history overview of ultras movement, as well as an overview of basic activities of ultras fans during a football match and also outside of it. The second part of this text deals with the most debated activity of football fans, which is violence during a football match.

  14. Rowing Injuries

    DEFF Research Database (Denmark)

    Thornton, Jane S; Vinther, Anders; Wilson, Fiona

    2017-01-01

    understanding in pre-participation screening, training load, emerging concepts surrounding back and rib injury, and relative energy deficiency in sport. Through a better understanding of the nature of the sport and mechanisms of injury, physicians and other healthcare providers will be better equipped to treat...

  15. Do ultra-orphan medicinal products warrant ultra-high prices? A review

    Directory of Open Access Journals (Sweden)

    Picavet E

    2013-06-01

    Full Text Available Eline Picavet,1 David Cassiman,2 Steven Simoens1 1Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Leuven, Belgium; 2Department of Hepatology, University Hospital Leuven, Leuven, Belgium Abstract: Ultra-orphan medicinal products (ultra-OMPs are intended for the treatment, prevention, or diagnosis of ultra-rare diseases, ie, life-threatening or chronically debilitating diseases that affect less than one per 50,000 individuals. Recently, high prices for ultra-OMPs have given rise to debate on the sustainability and justification of these prices. The aim of this article is to review the international scientific literature on the pricing of ultra-OMPs and to provide an overview of the current knowledge on the drivers of ultra-OMP pricing. The pricing process of ultra-OMPs is a complex and nontransparent issue. Evidence in the literature seems to indicate that ultra-OMPs are priced according to rarity and what the manufacturer believes the market will bear. Additionally, there appears to be a trend between the price of an ultra-OMP and the number of available alternatives. Patients, third-party payers, and pharmaceutical companies could benefit from more transparent pricing strategies. With a view to containing health care costs, it is likely that cost-sharing strategies, such as performance-based risk sharing arrangements, will become increasingly more important. However, it is vital that any measures for price control are consistent with the intended goals of the incentives to promote the development of new OMPs. Ideally, a balance must be struck between attaining affordable prices for ultra-OMPs and securing a realistic return on investment for the pharmaceutical industry. Keywords: ultra-orphan medicinal product, ultra-rare disease, pricing

  16. Ultra-high-energy cosmic rays from radio galaxies

    Science.gov (United States)

    Eichmann, B.; Rachen, J. P.; Merten, L.; van Vliet, A.; Becker Tjus, J.

    2018-02-01

    Radio galaxies are intensively discussed as the sources of cosmic rays observed above about 3 × 1018 eV, called ultra-high energy cosmic rays (UHECRs). We present a first, systematic approach that takes the individual characteristics of these sources into account, as well as the impact of the extragalactic magnetic-field structures up to a distance of 120 Mpc. We use a mixed simulation setup, based on 3D simulations of UHECRs ejected by observed, individual radio galaxies taken out to a distance of 120 Mpc, and on 1D simulations over a continuous source distribution contributing from beyond 120 Mpc. Additionally, we include the ultra-luminous radio galaxy Cygnus A at a distance of about 250 Mpc, as its contribution is so strong that it must be considered as an individual point source. The implementation of the UHECR ejection in our simulation setup, both that of individual radio galaxies and the continuous source function, is based on a detailed consideration of the physics of radio jets and standard first-order Fermi acceleration. This allows to derive the spectrum of ejected UHECR as a function of radio luminosity, and at the same time provides an absolute normalization of the problem involving only a small set of parameters adjustable within narrow constraints. We show that the average contribution of radio galaxies taken over a very large volume cannot explain the observed features of UHECRs measured at Earth. However, we obtain excellent agreement with the spectrum, composition, and arrival-direction distribution of UHECRs measured by the Pierre Auger Observatory, if we assume that most UHECRs observed arise from only two sources: the ultra-luminous radio galaxy Cygnus A, providing a mostly light composition of nuclear species dominating up to about 6 × 1019 eV, and the nearest radio galaxy Centaurus A, providing a heavy composition dominating above 6 × 1019 eV . Here we have to assume that extragalactic magnetic fields out to 250 Mpc, which we did not

  17. Age, sex and (the) race: gender and geriatrics in the ultra-endurance age.

    Science.gov (United States)

    Whyte, Greg

    2014-01-01

    Ultra-endurance challenges were once the stuff of legend isolated to the daring few who were driven to take on some of the greatest physical endurance challenges on the planet. With a growing fascination for major physical challenges during the nineteenth century, the end of the Victorian era witnessed probably the greatest ultra-endurance race of all time; Scott and Amundsen's ill-fated race to the South Pole. Ultra-endurance races continued through the twentieth century; however, these events were isolated to the elite few. In the twenty-first century, mass participation ultra-endurance races have grown in popularity. Endurance races once believed to be at the limit of human durability, i.e. marathon running, are now viewed as middle-distance races with the accolade of true endurance going to those willing to travel significantly further in a single effort or over multiple days. The recent series of papers in Extreme Physiology & Medicine highlights the burgeoning research data from mass participation ultra-endurance events. In support of a true 'mass participation' ethos Knetchtle et al. reported age-related changes in Triple and Deca Iron-ultra-triathlon with an upper age of 69 years! Unlike their shorter siblings, the ultra-endurance races appear to present larger gender differences in the region of 20% to 30% across distance and modality. It would appear that these gender differences remain for multi-day events including the 'Marathon des Sables'; however, this gap may be narrower in some events, particularly those that require less load bearing (i.e. swimming and cycling), as evidenced from the 'Ultraman Hawaii' and 'Swiss Cycling Marathon', and shorter (a term I used advisedly!) distances including the Ironman Triathlon where differences are similar to those of sprint and endurance distances i.e. c. 10%. The theme running through this series of papers is a continual rise in participation to the point where major events now require selection races to remain

  18. Effect of single- and double-row rotator cuff repair at the tendon-to-bone interface: preliminary results using an in vivo sheep model.

    Science.gov (United States)

    Baums, M H; Schminke, B; Posmyk, A; Miosge, N; Klinger, H-M; Lakemeier, S

    2015-01-01

    The clinical superiority of the double-row technique is still a subject of controversial debate in rotator cuff repair. We hypothesised that the expression of different collagen types will differ between double-row and single-row rotator cuff repair indicating a faster healing response by the double-row technique. Twenty-four mature female sheep were randomly assembled to two different groups in which a surgically created acute infraspinatus tendon tear was fixed using either a modified single- or double-row repair technique. Shoulder joints from female sheep cadavers of identical age, bone maturity, and weight served as untreated control cluster. Expression of type I, II, and III collagen was observed in the tendon-to-bone junction along with recovering changes in the fibrocartilage zone after immunohistological tissue staining at 1, 2, 3, 6, 12, and 26 weeks postoperatively. Expression of type III collagen remained positive until 6 weeks after surgery in the double-row group, whereas it was detectable for 12 weeks in the single-row group. In both groups, type I collagen expression increased after 12 weeks. Type II collagen expression was increased after 12 weeks in the double-row versus single-row group. Clusters of chondrocytes were only visible between week 6 and 12 in the double-row group. The study demonstrates differences regarding the expression of type I and type III collagen in the tendon-to-bone junction following double-row rotator cuff repair compared to single-row repair. The healing response in this acute repair model is faster in the double-row group during the investigated healing period.

  19. Effect of shoulder abduction angle on biomechanical properties of the repaired rotator cuff tendons with 3 types of double-row technique.

    Science.gov (United States)

    Mihata, Teruhisa; Fukuhara, Tetsutaro; Jun, Bong Jae; Watanabe, Chisato; Kinoshita, Mitsuo

    2011-03-01

    After rotator cuff repair, the shoulder is immobilized in various abduction positions. However, there is no consensus on the proper abduction angle. To assess the effect of shoulder abduction angle on the biomechanical properties of the repaired rotator cuff tendons among 3 types of double-row techniques. Controlled laboratory study. Thirty-two fresh-frozen porcine shoulders were used. A simulated rotator cuff tear was repaired by 1 of 3 double-row techniques: conventional double-row repair, transosseous-equivalent repair, and a combination of conventional double-row and bridging sutures (compression double-row repair). Each specimen underwent cyclic testing followed by tensile testing to failure at a simulated shoulder abduction angle of 0° or 40° on a material testing machine. Gap formation and failure loads were measured. Gap formation in conventional double-row repair at 0° (1.2 ± 0.5 mm) was significantly greater than that at 40° (0.5 ± 0.3mm, P = .01). The yield and ultimate failure loads for conventional double-row repair at 40° were significantly larger than those at 0° (P row repair (P row repair was the greatest among the 3 double-row techniques at both 0° and 40° of abduction. Bridging sutures have a greater effect on the biomechanical properties of the repaired rotator cuff tendon at a low abduction angle, and the conventional double-row technique has a greater effect at a high abduction angle. Proper abduction position after rotator cuff repair differs between conventional double-row repair and transosseous-equivalent repair. The authors recommend the use of the combined technique of conventional double-row and bridging sutures to obtain better biomechanical properties at both low and high abduction angles.

  20. Introduction to Ultra Wideband for Wireless Communications

    DEFF Research Database (Denmark)

    Nikookar, Homayoun; Prasad, Ramjee

    wireless channels, interference, signal processing as well as applications and standardization activities are addressed. Introduction to Ultra Wideband for Wireless Communications provides easy-to-understand material to (graduate) students and researchers working in the field of commercial UWB wireless......Ultra Wideband (UWB) Technology is the cutting edge technology for wireless communications with a wide range of applications. In Introduction to Ultra Wideband for Wireless Communications UWB principles and technologies for wireless communications are explained clearly. Key issues such as UWB...... communications. Due to tutorial nature of the book it can also be adopted as a textbook on the subject in the Telecommunications Engineering curriculum. Problems at the end of each chapter extend the reader's understanding of the subject. Introduction to Ultra Wideband for Wireless Communications will aslo...

  1. An ultra-broadband multilayered graphene absorber

    KAUST Repository

    Amin, Muhammad; Farhat, Mohamed; Bagci, Hakan

    2013-01-01

    An ultra-broadband multilayered graphene absorber operating at terahertz (THz) frequencies is proposed. The absorber design makes use of three mechanisms: (i) The graphene layers are asymmetrically patterned to support higher order surface plasmon

  2. ULTRA-RELATIVISTIC NUCLEI: A NEW FRONTIER

    International Nuclear Information System (INIS)

    MCLERRAN, L.

    1999-01-01

    The collisions of ultra-relativistic nuclei provide a window on the behavior of strong interactions at asymptotically high energies. They also will allow the authors to study the bulk properties of hadronic matter at very high densities

  3. Ultra-high temperature direct propulsion

    International Nuclear Information System (INIS)

    Araj, K.J.; Slovik, G.; Powell, J.R.; Ludewig, H.

    1987-01-01

    Potential advantages of ultra-high exhaust temperature (3000 K - 4000 K) direct propulsion nuclear rockets are explored. Modifications to the Particle Bed Reactor (PBR) to achieve these temperatures are described. Benefits of ultra-high temperature propulsion are discussed for two missions - orbit transfer (ΔV = 5546 m/s) and interplanetary exploration (ΔV = 20000 m/s). For such missions ultra-high temperatures appear to be worth the additional complexity. Thrust levels are reduced substantially for a given power level, due to the higher enthalpy caused by partial disassociation of the hydrogen propellant. Though technically challenging, it appears potentially feasible to achieve such ultra high temperatures using the PBR

  4. Ultra wideband antennas design, methodologies, and performance

    CERN Document Server

    Galvan-Tejada, Giselle M; Jardón Aguilar, Hildeberto

    2015-01-01

    Ultra Wideband Antennas: Design, Methodologies, and Performance presents the current state of the art of ultra wideband (UWB) antennas, from theory specific for these radiators to guidelines for the design of omnidirectional and directional UWB antennas. Offering a comprehensive overview of the latest UWB antenna research and development, this book:Discusses the developed theory for UWB antennas in frequency and time domainsDelivers a brief exposition of numerical methods for electromagnetics oriented to antennasDescribes solid-planar equivalen

  5. Evaluation of multiple trauma victims with 16-row multidetector CT (MDCT): a time analysis

    International Nuclear Information System (INIS)

    Heyer, C.M.; Nicolas, V.

    2005-01-01

    Purpose: Description and time analysis of a 16-row MDCT protocol in the evaluation of multiple trauma patients considering transport, time of scanning, patient positioning, image reconstruction, and image interpretation. Materials and methods: Between May and December 2004, 60 multiple trauma patients underwent 16-row MDCT (Sensation, Siemens, Erlangen, Germany). The protocol included serial scanning of the head, spiral scanning of the cervical spine and contrast-enhanced spiral scanning of the thorax/abdomen with multiplanar reformations (MPR) of the thoracic/lumbar spine and the pelvis. All time intervals including transport, patient positioning, scanning, duration of MPR, total time in the examination room, and time to first and final image interpretation were prospectively evaluated. Furthermore, patient characteristics, trauma profiles, and mortality rates were recorded. Results: 46 male and 14 female patients (mean age 43.6 years) were enrolled in the study. Time analysis of 16-row MDCT revealed the following results (mean time standard deviation): Emergency room treatment and transport 19.2±6.7 min, patient positioning 16.5±6.5 min, scan duration 8.0±3.3 min, total time in examination room 24.5±7.2 min, image reconstruction including MPR 32.0±16.4 min, and time of first (16.4±4.7 min) and final image interpretation (82.5±30.4 min). Trauma profiles revealed thoracic injuries in 35/60 patients (58.3%), head injuries in 23/60 patients (38.3%), abdominal injuries in 15/60 patients (25.0%), injuries of the cervical (9/60 patients, 15.0%), thoracic (12/60 patients, 20.0%), and lumbar spine (19/60 patients, 31.7%), pelvic injuries in 13/60 patients (21.7%), and injuries of extremities in 39/60 patients (65.0%). The mortality rate was 21.7%. (orig.)

  6. Reliability and effect of sodium bicarbonate: buffering and 2000-m rowing performance.

    Science.gov (United States)

    Carr, Amelia J; Slater, Gary J; Gore, Christopher J; Dawson, Brian; Burke, Louise M

    2012-06-01

    The aim of this study was to determine the effect and reliability of acute and chronic sodium bicarbonate ingestion for 2000-m rowing ergometer performance (watts) and blood bicarbonate concentration [HCO3-]. In a crossover study, 7 well-trained rowers performed paired 2000-m rowing ergometer trials under 3 double-blinded conditions: (1) 0.3 grams per kilogram of body mass (g/kg BM) acute bicarbonate; (2) 0.5 g/kg BM daily chronic bicarbonate for 3 d; and (3) calcium carbonate placebo, in semi-counterbalanced order. For 2000-m performance and [HCO3-], we examined differences in effects between conditions via pairwise comparisons, with differences interpreted in relation to the likelihood of exceeding smallest worthwhile change thresholds for each variable. We also calculated the within-subject variation (percent typical error). There were only trivial differences in 2000-m performance between placebo (277 ± 60 W), acute bicarbonate (280 ± 65 W) and chronic bicarbonate (282 ± 65 W); however, [HCO3-] was substantially greater after acute bicarbonate, than with chronic loading and placebo. Typical error for 2000-m mean power was 2.1% (90% confidence interval 1.4 to 4.0%) for acute bicarbonate, 3.6% (2.5 to 7.0%) for chronic bicarbonate, and 1.6% (1.1 to 3.0%) for placebo. Postsupplementation [HCO3-] typical error was 7.3% (5.0 to 14.5%) for acute bicarbonate, 2.9% (2.0 to 5.7%) for chronic bicarbonate and 6.0% (1.4 to 11.9%) for placebo. Performance in 2000-m rowing ergometer trials may not substantially improve after acute or chronic bicarbonate loading. However, performances will be reliable with both acute and chronic bicarbonate loading protocols.

  7. Biomechanical evaluation of knotless anatomical double-layer double-row rotator cuff repair: a comparative ex vivo study.

    Science.gov (United States)

    Hepp, Pierre; Osterhoff, Georg; Engel, Thomas; Marquass, Bastian; Klink, Thomas; Josten, Christoph

    2009-07-01

    The layered configuration of the rotator cuff tendon is not taken into account in classic rotator cuff tendon repair techniques. The mechanical properties of (1) the classic double-row technique, (2) a double-layer double-row (DLDR) technique in simple suture configuration, and (3) a DLDR technique in mattress suture configuration are significantly different. Controlled laboratory study. Twenty-four sheep shoulders were assigned to 3 repair groups of full-thickness infraspinatus tears: group 1, traditional double-row repair; group 2, DLDR anchor repair with simple suture configuration; and group 3, DLDR knotless repair with mattress suture configuration. After ultrasound evaluation of the repair, each specimen was cyclically loaded with 10 to 100 N for 50 cycles. Each specimen was then loaded to failure at a rate of 1 mm/s. There were no statistically significant differences among the 3 testing groups for the mean footprint area. The cyclic loading test revealed no significant difference among the 3 groups with regard to elongation. For the load-to-failure test, groups 2 and 3 showed no differences in ultimate tensile load when compared with group 1. However, when compared to group 2, group 3 was found to have significantly higher values regarding ultimate load, ultimate elongation, and energy absorbed. The DLDR fixation techniques may provide strength of initial repair comparable with that of commonly used double-row techniques. When compared with the knotless technique with mattress sutures, simple suture configuration of DLDR repair may be too weak. Knotless DLDR rotator cuff repair may (1) restore the footprint by the use of double-row principles and (2) enable restoration of the shape and profile. Double-layer double-row fixation in mattress suture configuration has initial fixation strength comparable with that of the classic double-row fixation and so may potentially improve functional results of rotator cuff repair.

  8. Metal-Ligand Bonds of Second- and Third-Row d-Block Metals Characterized by Density Functional Theory

    Science.gov (United States)

    Jensen, Kasper P.

    2009-08-01

    This paper presents systematic data for 200 neutral diatomic molecules ML (M is a second- or third-row d-block metal and L = H, F, Cl, Br, I, C, N, O, S, or Se) computed with the density functionals TPSSh and BP86. With experimental structures and bond enthalpies available for many of these molecules, the computations first document the high accuracy of TPSSh, giving metal-ligand bond lengths with a mean absolute error of ˜0.01 Å for the second row and 0.03 Å for the third row. TPSSh provides metal-ligand bond enthalpies with mean absolute errors of 37 and 44 kJ/mol for the second- and third-row molecules, respectively. Pathological cases (e.g., HgC and HgN) have errors of up to 155 kJ/mol, more than thrice the mean (observed with both functionals). Importantly, the systematic error component is negligible as measured by a coefficient of the linear regression line of 0.99. Equally important, TPSSh provides uniform accuracy across all three rows of the d-block, which is unprecedented and due to the 10% exact exchange, which is close to optimal for the d-block as a whole. This work provides an accurate and systematic prediction of electronic ground-state spins, characteristic metal-ligand bond lengths, and bond enthalpies for many as yet uncharacterized diatomics, of interest to researchers in the field of second- and third-row d-block chemistry. We stress that the success of TPSSh cannot be naively extrapolated to other special situations such as, e.g., metal-metal bonds. The high accuracy of the procedure further implies that the effective core functions used to model relativistic effects are necessary and sufficient for obtaining accurate geometries and bond enthalpies of second- and third-row molecular systems.

  9. The quality of reconstructed 3D images in multidetector-row helical CT: experimental study involving scan parameters

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Lee, Ho Kyu; Choi, Choong Gon; Suh, Dae Chul; Lim, Tae Hwan; Kang, Weechang

    2002-01-01

    To determine which multidetector-row helical CT scanning technique provides the best-quality reconstructed 3D images, and to assess differences in image quality according to the levels of the scanning parameters used. Four objects with different surfaces and contours were scanned using multidetector-row helical CT at three detector-row collimations (1.25, 2.50, 5.00 mm), two pitches (3.0, 6.0), and three different degrees of overlap between the reconstructed slices (0%, 25%, 50%). Reconstructed 3D images of the resulting 72 sets of data were produced using volumetric rendering. The 72 images were graded on a scale from 1 (worst) to 5 (best) for each of four rating criteria, giving a mean score for each criterion and an overall mean score. Statistical analysis was used to assess differences in image quality according to scanning parameter levels. The mean score for each rating criterion, and the overall mean score, varied significantly according to the scanning parameter levels used. With regard to detector-row collimation and pitch, all levels of scanning parameters gave rise to significant differences, while in the degree of overlap of reconstructed slices, there were significant differences between overlap of 0% and of 50% in all levels of scanning parameters, and between overlap of 25% and of 50% in overall accuracy and overall mean score. Among the 18 scanning sequences, the highest score (4.94) was achieved with 1.25 mm detector-row collimation, 3.0 pitch, and 50% overlap between reconstructed slices. Comparison of the quality of reconstructed 3D images obtained using multidetector-row helical CT and various scanning techniques indicated that the 1.25 mm, 3.0, 50% scanning sequence was best. Quality improved as detector-row collimation decreased; as pitch was reduced from 6.0 to 3.0; and as overlap between reconstructed slices increased

  10. Nasal base narrowing: the combined alar base excision technique.

    Science.gov (United States)

    Foda, Hossam M T

    2007-01-01

    To evaluate the role of the combined alar base excision technique in narrowing the nasal base and correcting excessive alar flare. The study included 60 cases presenting with a wide nasal base and excessive alar flaring. The surgical procedure combined an external alar wedge resection with an internal vestibular floor excision. All cases were followed up for a mean of 32 (range, 12-144) months. Nasal tip modification and correction of any preexisting caudal septal deformities were always completed before the nasal base narrowing. The mean width of the external alar wedge excised was 7.2 (range, 4-11) mm, whereas the mean width of the sill excision was 3.1 (range, 2-7) mm. Completing the internal excision first resulted in a more conservative external resection, thus avoiding any blunting of the alar-facial crease. No cases of postoperative bleeding, infection, or keloid formation were encountered, and the external alar wedge excision healed with an inconspicuous scar that was well hidden in the depth of the alar-facial crease. Finally, the risk of notching of the alar rim, which can occur at the junction of the external and internal excisions, was significantly reduced by adopting a 2-layered closure of the vestibular floor (P = .01). The combined alar base excision resulted in effective narrowing of the nasal base with elimination of excessive alar flare. Commonly feared complications, such as blunting of the alar-facial crease or notching of the alar rim, were avoided by using simple modifications in the technique of excision and closure.

  11. Vacuum Bloch-Siegert shift in Landau polaritons with ultra-high cooperativity

    Science.gov (United States)

    Li, Xinwei; Bamba, Motoaki; Zhang, Qi; Fallahi, Saeed; Gardner, Geoff C.; Gao, Weilu; Lou, Minhan; Yoshioka, Katsumasa; Manfra, Michael J.; Kono, Junichiro

    2018-06-01

    A two-level system resonantly interacting with an a.c. magnetic or electric field constitutes the physical basis of diverse phenomena and technologies. However, Schrödinger's equation for this seemingly simple system can be solved exactly only under the rotating-wave approximation, which neglects the counter-rotating field component. When the a.c. field is sufficiently strong, this approximation fails, leading to a resonance-frequency shift known as the Bloch-Siegert shift. Here, we report the vacuum Bloch-Siegert shift, which is induced by the ultra-strong coupling of matter with the counter-rotating component of the vacuum fluctuation field in a cavity. Specifically, an ultra-high-mobility two-dimensional electron gas inside a high-Q terahertz cavity in a quantizing magnetic field revealed ultra-narrow Landau polaritons, which exhibited a vacuum Bloch-Siegert shift up to 40 GHz. This shift, clearly distinguishable from the photon-field self-interaction effect, represents a unique manifestation of a strong-field phenomenon without a strong field.

  12. Ultra-High Density Single Nanometer-Scale Anodic Alumina Nanofibers Fabricated by Pyrophosphoric Acid Anodizing

    Science.gov (United States)

    Kikuchi, Tatsuya; Nishinaga, Osamu; Nakajima, Daiki; Kawashima, Jun; Natsui, Shungo; Sakaguchi, Norihito; Suzuki, Ryosuke O.

    2014-12-01

    Anodic oxide fabricated by anodizing has been widely used for nanostructural engineering, but the nanomorphology is limited to only two oxides: anodic barrier and porous oxides. Therefore, the discovery of an additional anodic oxide with a unique nanofeature would expand the applicability of anodizing. Here we demonstrate the fabrication of a third-generation anodic oxide, specifically, anodic alumina nanofibers, by anodizing in a new electrolyte, pyrophosphoric acid. Ultra-high density single nanometer-scale anodic alumina nanofibers (1010 nanofibers/cm2) consisting of an amorphous, pure aluminum oxide were successfully fabricated via pyrophosphoric acid anodizing. The nanomorphologies of the anodic nanofibers can be controlled by the electrochemical conditions. Anodic tungsten oxide nanofibers can also be fabricated by pyrophosphoric acid anodizing. The aluminum surface covered by the anodic alumina nanofibers exhibited ultra-fast superhydrophilic behavior, with a contact angle of less than 1°, within 1 second. Such ultra-narrow nanofibers can be used for various nanoapplications including catalysts, wettability control, and electronic devices.

  13. Investigating the Temperature Problem in Narrow Line Emitting AGN

    Science.gov (United States)

    Jenkins, Sam; Richardson, Chris T.

    2018-06-01

    Our research investigates the physical conditions in gas clouds around the narrow line region of AGN. Specifically, we explore the necessary conditions for anomalously high electron temperatures, Te, in those clouds. Our 321 galaxy data set was acquired from SDSS DR14 after requiring S/N > 5.0 in [OIII] 4363 and S/N > 3.0 in all BPT diagram emission lines, to ensure both accurate Te and galaxy classification, with 0.04 study the effects these conditions have on gas cloud Te.

  14. Internalization of Calcium Oxalate Calculi Developed in Narrow Cavities

    Directory of Open Access Journals (Sweden)

    Fèlix Grases

    2014-03-01

    Full Text Available We describe the case of a patient with calcium oxalate monohydrate and calcium oxalate dihydrate calculi occluded in cavities. All those calculi were located inside narrow cavities covered with a thin epithelium that permits their visualization. Urinary biochemical analysis showed high calciuria, not hypercalciuria, hypocitraturia, and a ratio [calcium]/[citrate] >0.33. The existence of cavities of very low urodynamic efficacy was decisive in the formation of such calculi. It is important to emphasize that we observed a thin epithelium covering such cavities, demonstrating that this epithelium may be formed after the development of the calculi through a re-epithelialization process.

  15. Bubble departure diameter in narrow rectangular channel under rolling condition

    Energy Technology Data Exchange (ETDEWEB)

    Xie, T.; Chen, B.; Yan, X.; Xu, J.; Huang, Y.; Xiao, Z. [Nuclear Power Inst. of China, Chengdu, Sichuan (China)

    2014-07-01

    Forced convective subcooled boiling flow experiments were conducted in a vertical upward narrow rectangular channel under rolling motion. A high-speed digital video camera was used to capture the dynamics of the bubble nucleation process. Bubble departure diameters were obtained from the images. A bubble departure model based on force balance analysis was proposed to predict the bubble departure size under rolling condition by considering the additional centrifugal, tangential and Coriolis force. The proposed model agreed well with the experimental data within the averaged relative deviation of 5%. (author)

  16. The Chemical Vapour Deposition of Tantalum - in long narrow channels

    DEFF Research Database (Denmark)

    Mugabi, James Atwoki

    protective layers of tantalum because of the process’ ability to coat complex geometries and its relative ease to control. This work focuses on studying the CVD of tantalum in long narrow channels with the view that the knowledge gained during the project can be used to optimise the commercial coating...... and that there is a major change in morphology between 850 – 900 °C. The effects of system pressure and precursor partial pressure are also studied, and were found to have relevance to the tantalum distribution along the substrates but little effect on the structural morphology of the deposited layer. In the implemented...

  17. Period Effects, Cohort Effects, and the Narrowing Gender Wage Gap

    OpenAIRE

    Campbell, Colin; Pearlman, Jessica

    2013-01-01

    Despite the abundance of sociological research on the gender wage gap, questions remain. In particular, the role of cohorts is under investigated. Using data from the Current Population Survey, we use Age-Period-Cohort analysis to uniquely estimate age, period, and cohort effects on the gender wage gap. The narrowing of the gender wage gap that occurred between 1975 and 2009 is largely due to cohort effects. Since the mid-1990s, the gender wage gap has continued to close absent of period effe...

  18. Regioregular narrow-bandgap-conjugated polymers for plastic electronics

    Science.gov (United States)

    Ying, Lei; Huang, Fei; Bazan, Guillermo C.

    2017-03-01

    Progress in the molecular design and processing protocols of semiconducting polymers has opened significant opportunities for the fabrication of low-cost plastic electronic devices. Recent studies indicate that field-effect transistors and organic solar cells fabricated using narrow-bandgap regioregular polymers with translational symmetries in the direction of the backbone vector often outperform those containing analogous regiorandom polymers. This review addresses the cutting edge of regioregularity chemistry, in particular how to control the spatial distribution in the molecular structures and how this order translates to more ordered bulk morphologies. The effect of regioregularity on charge transport and photovoltaic properties is also outlined.

  19. The role of rare earths in narrow energy gap semiconductors

    International Nuclear Information System (INIS)

    Partin, D.L.; Heremans, J.; Morelli, D.T.; Thrush, C.M.

    1991-01-01

    Narrow energy band gap semiconductors are potentially useful for various devices, including infrared detectors and diode lasers. Rare earth elements have been introduced into lead chalcogenide semiconductors using the molecular beam epitaxy growth process. Europium and ytterbium increase the energy band gap, and nearly lattice-matched heterojunctions have been grown. In some cases, valence changes in the rare earth element cause doping of the alloy. In this paper some initial investigations of the addition of europium to indium antimonide are reported, including the variation of lattice parameter and optical transmission with composition and a negative magnetoresistance effect

  20. Are Narrow Line Seyfert 1 Galaxies Viewed Pole-on?

    Science.gov (United States)

    2011-04-01

    0.2’’ respectively. Figure 1 displays the position of each slit over a Barbosa et al. (2009) GMOS IFU image of the [S III] flux (which originates...C. Winge, H. Schmitt: Gemini/ GMOS IFU gas velocity ’tomography’ of the narrow line region of nearby active galaxies, MNRAS, 396 (2009) 2. [2] D...1995) 81. 4 P o S ( N L S 1 ) 0 5 0 Are NLS1s Pole-on? Travis C. Fischer 5 Figure 1: NGC 4051 GMOS IFU image showing integrated [SIII] flux