WorldWideScience

Sample records for uars mls measurements

  1. Validation of UARS Microwave Limb Sounder 183 GHz H2O Measurements

    Science.gov (United States)

    Lahoz, W. A.; Suttie, M. R.; Froidevaux, L.; Harwood, R. S.; Lau, C. L.; Lungu, T. A.; Peckham, G. E.; Pumphrey, H. C.; Read, W. G.; Shippony, Z.; hide

    1996-01-01

    The Upper Atmosphere Research Satellite (UARS) microwave limb sounder (MLS) makes measurements of thermal emission at 183.3 GHz which are used to infer the concentration of water vapor over a pressure range of 46-0.2hPa (approximately 20-60 km). We provide a validation of MLS H2O by analyzing the integrity of the measurements, by providing an error characterization, and by comparison with data from other instruments. It is estimated that version 3 MLS H2O retrievals are accurate to within 20-25% in the lower stratosphere and to within 8-13% in the upper stratosphere and lower mesosphere. The precision of a single profile is estimated to be approximately 0.15 parts per million by volume (ppmv) in the midstratosphere and 0.2 ppmv in the lower and upper stratosphere. In the lower mesosphere the estimate of a single profile precision is 0.25-0.45 ppmv. During polar winter conditions, H2O retrievals at 46 hPa can have a substantial contribution from climatology. The vertical resolution of MLS H2O retrievals is approximately 5 km.

  2. Analysis of Temperature and Wind Measurements from the TIMED Mission: Comparison with UARS Data

    Science.gov (United States)

    Huang, Frank; Mayr, Hans; Killeen, Tim; Russell, Jim; Reber, Skip

    2004-01-01

    We report on an analysis of temperature and wind data based respectively on measurements with the SABER (Sounding of the Atmosphere using Broadband Emission Radiometry) and TIDI (TIMED Doppler Interferometer) instruments on the TIMED (Thermosphere-Ionosphere-Mesosphere-Energetics and Dynamics) mission. Comparisons are made with corresponding results obtained from the HRDI (High Resolution Doppler Imager), MLS (Microwave Limb Sounder) and CLAES (Cryogenic Limb Array Etalon Spectrometer) instruments on the UARS (Upper Atmosphere Research Satellite) spacecraft. The TIMED and UARS instruments have important common and uncommon properties in their sampling of the data as a function local solar time. For comparison between the data from the two satellite missions, we present the derived diurnal tidal and zonal-mean variations of temperature and winds, obtained as functions of season, latitude, and altitude. The observations are also compared with results from the Numerical Spectral Model (NSM).

  3. Space-time patterns of trends in stratospheric constituents derived from UARS measurements

    Science.gov (United States)

    Randel, William J.; Wu, Fei; Russell, James M.; Waters, Joe

    1999-02-01

    The spatial and temporal behavior of low-frequency changes (trends) in stratospheric constituents measured by instruments on the Upper Atmosphere Research Satellite (UARS) during 1991-98 is investigated. The data include CH4, H2O, HF, HCl, O3, and NO2 from the Halogen Occultation Experiment (HALOE), and O3, ClO, and HNO3 from the Microwave Limb Sounder (MLS). Time series of global anomalies are analyzed by linear regression and empirical orthogonal function analysis. Each of the constituents show significant linear trends over at least some region of the stratosphere, and the spatial patterns exhibit coupling between the different species. Several of the constituents (namely CH4, H2O, HF, HCl, O3, and NO2) exhibit a temporal change in trend rates, with strong changes prior to 1996 and weaker (or reversed) trends thereafter. Positive trends are observed in upper stratospheric ClO, with a percentage rate during 1993-97 consistent with stratospheric HCl increases and with tropospheric chlorine emission rates. Significant negative trends in ozone in the tropical middle stratosphere are found in both HALOE and MLS data during 1993-97, together with positive trends in the tropics near 25 km. These trends are very different from the decadal-scale ozone trends observed since 1979, and this demonstrates the variability of trends calculated over short time periods. Positive trends in NO2 are found in the tropical middle stratosphere, and spatial coincidence to the observed ozone decreases suggests the ozone is responding to the NO2 increase. Significant negative trends in HNO3 are found in the lower stratosphere of both hemispheres. These coupled signatures offer a fingerprint of chemical evolution in the stratosphere for the UARS time frame.

  4. ISAMS and MLS for NASA's Upper Atmosphere Research Satellite

    Science.gov (United States)

    Llewellyn-Jones, D.; Dickinson, P. H. G.

    1990-04-01

    The primary goal of NASA's Upper Atmosphere Research Satellite (UARS), planned to be launched in 1991, is to compile data about the structure and behavior of the stratospheric ozone layer, and especially about the threat of the chlorine-based pollutants to its stablility. Two of the payload instruments, manufactured in the UK, are described: the Improved Stratospheric and Mesospheric Sounder (ISAMS), a radiometer designed to measure thermal emission from selected atmospheric constituents at the earth's limb, then making it possible to obtain nearly global coverage of the vertical distribution of temperature and composition from 80 deg S to 80 deg N latitude; and the Microwave Limb Sounder (MLS), a limb sounding radiometer, measuring atmospheric thermal emission from selected molecular spectral lines at mm wavelength, in the frequency regions of 63, 183, and 205 GHz.

  5. SABER (TIMED) and MLS (UARS) Temperature Observations of Mesospheric and Stratospheric QBO and Related Tidal Variations

    Science.gov (United States)

    Huang, Frank T.; Mayr, Hans G.; Reber, Carl A.; Russell, James; Mlynczak, Marty; Mengel, John

    2006-01-01

    More than three years of temperature observations from the SABER (TIMED) and MLS WARS) instruments are analyzed to study the annual and inter-annual variations extending from the stratosphere into the upper mesosphere. The SABER measurements provide data from a wide altitude range (15 to 95 km) for the years 2002 to 2004, while the MLS data were taken in the 16 to 55 km altitude range a decade earlier. Because of the sampling properties of SABER and MLS, the variations with local solar time must be accounted for when estimating the zonal mean variations. An algorithm is thus applied that delineates with Fourier analysis the year-long variations of the migrating tides and zonal mean component. The amplitude of the diurnal tide near the equator shows a strong semiannual periodicity with maxima near equinox, which vary from year to year to indicate the influence from the Quasi-biennial Oscillation (QBO) in the zonal circulation. The zonal mean QBO temperature variations are analyzed over a range of latitudes and altitudes, and the results are presented for latitudes from 48"s to 48"N. New results are obtained for the QBO, especially in the upper stratosphere and mesosphere, and at mid-latitudes. At Equatorial latitudes, the QBO amplitudes show local peaks, albeit small, that occur at different altitudes. From about 20 to 40 km, and within about 15" of the Equator, the amplitudes can approach 3S K for the stratospheric QBO or SQBO. For the mesospheric QBO or MQBO, we find peaks near 70 km, with temperature amplitudes reaching 3.5"K, and near 85 km, the amplitudes approach 2.5OK. Morphologically, the amplitude and phase variations derived from the SABER and MLS measurements are in qualitative agreement. The QBO amplitudes tend to peak at the Equator but then increase again pole-ward of about 15" to 20'. The phase progression with altitude varies more gradually at the Equator than at mid-latitudes. A comparison of the observations with results from the Numerical Spectral

  6. Modeling the diurnal tide with dissipation derived from UARS/HRDI measurements

    Directory of Open Access Journals (Sweden)

    M. A. Geller

    1997-09-01

    Full Text Available This paper uses dissipation values derived from UARS/HRDI observations in a recently published diurnal-tide model. These model structures compare quite well with the UARS/HRDI observations with respect to the annual variation of the diurnal tidal amplitudes and the size of the amplitudes themselves. It is suggested that the annual variation of atmospheric dissipation in the mesosphere-lower thermosphere is a major controlling factor in determining the annual variation of the diurnal tide.

  7. Intra-seasonal Oscillations (ISO of zonal-mean meridional winds and temperatures as measured by UARS

    Directory of Open Access Journals (Sweden)

    F. T. Huang

    2005-06-01

    Full Text Available Based on an empirical analysis of measurements with the High Resolution Doppler Imager (HRDI on the UARS spacecraft in the upper mesosphere (95km, persistent and regular intra-seasonal oscillations (ISO with periods of about 2 to 4 months have recently been reported in the zonal-mean meridional winds. Similar oscillations have also been discussed independently in a modeling study, and they were attributed to wave-mean-flow interactions. The observed and modeled meridional wind ISOs were largely confined to low latitudes. We report here on an analysis of concurrent UARS temperature measurements, which produces oscillations similar to those seen in the meridional winds. Although the temperature oscillations are observed at lower altitudes (55km, their phase variations with latitude are qualitatively consistent with the inferred properties seen in the meridional winds and thus provide independent evidence for the existence of ISOs in the mesosphere.

  8. Tropical stratospheric water vapor measured by the microwave limb sounder (MLS)

    Science.gov (United States)

    Carr, E. S.; Harwood, R. S.; Mote, P. W.; Peckham, G. E.; Suttie, R. A.; Lahoz, W. A.; O'Neill, A.; Froidevaux, L.; Jarnot, R. F.; Read, W. G.

    1995-01-01

    The lower stratospheric variability of equatorial water vapor, measured by the Microwave Limb Sounder (MLS), follows an annual cycle modulated by the quasi-biennial oscillation. At levels higher in the stratosphere, water vapor measurements exhibit a semi-annual oscillatory signal with the largest amplitudes at 2.2 and 1hPa. Zonal-mean cross sections of MLS water vapor are consistent with previous satellite measurements from the limb infrared monitor of the stratosphere (LIMS) and the stratospheric Aerosol and Gas Experiment 2 (SAGE 2) instruments in that they show water vapor increasing upwards and the polewards from a well defined minimum in the tropics. The minimum values vary in height between the retrieved 46 and 22hPa pressure levels.

  9. An MLS coherence function and its performance in measurements on time-varying systems

    DEFF Research Database (Denmark)

    Liu, Jiyuan; Jacobsen, Finn

    1999-01-01

    A new MLS coherence function has been developed and tested in various room acoustic measurements. The new measure, which takes values between zero and unity just as the ordinary coherence, can be used only if averaging over several periods of the MLS signal is carried out. It indicates possible...... contamination by extraneous noise in the same manner as the the ordinary coherence function does in measurements with FFT analysers. It is also very sensitive to disturbances such as reflections caused by moving surfaces during the measurement. Very weak time-variance effects caused by a small change...

  10. MLS measurements of stratospheric hydrogen cyanide during the 2015-2016 El Niño event

    Science.gov (United States)

    Pumphrey, Hugh C.; Glatthor, Norbert; Bernath, Peter F.; Boone, Christopher D.; Hannigan, James W.; Ortega, Ivan; Livesey, Nathaniel J.; Read, William G.

    2018-01-01

    It is known from ground-based measurements made during the 1982-1983 and 1997-1998 El Niño events that atmospheric hydrogen cyanide (HCN) tends to be higher during such years than at other times. The Microwave Limb Sounder (MLS) on the Aura satellite has been measuring HCN mixing ratios since launch in 2004; the measurements are ongoing at the time of writing. The winter of 2015-2016 saw the largest El Niño event since 1997-1998. We present MLS measurements of HCN in the lower stratosphere for the Aura mission to date, comparing the 2015-2016 El Niño period to the rest of the mission. HCN in 2015-2016 is higher than at any other time during the mission, but ground-based measurements suggest that it may have been even more elevated in 1997-1998. As the MLS HCN data are essentially unvalidated, we show them alongside data from the MIPAS and ACE-FTS instruments; the three instruments agree reasonably well in the tropical lower stratosphere. Global HCN emissions calculated from the Global Fire Emissions Database (GFED v4.1) database are much greater during large El Niño events and are greater in 1997-1998 than in 2015-2016, thereby showing good qualitative agreement with the measurements. Correlation between El Niño-Southern Oscillation (ENSO) indices, measured HCN, and GFED HCN emissions is less clear if the 2015-2016 event is excluded. In particular, the 2009-2010 winter had fairly strong El Niño conditions and fairly large GFED HCN emissions, but very little effect is observed in the MLS HCN.

  11. Upper Atmosphere Research Satellite (UARS) science data processing center implementation history

    Science.gov (United States)

    Herring, Ellen L.; Taylor, K. David

    1990-01-01

    NASA-Goddard is responsible for the development of a ground system for the Upper Atmosphere Research Satellite (UARS) observatory, whose launch is scheduled for 1991. This ground system encompasses a dedicated Central Data Handling Facility (CDHF); attention is presently given to the management of software systems design and implementation phases for CDHF by the UARS organization. Also noted are integration and testing activities performed following software deliveries to the CDHF. The UARS project has an obvious requirement for a powerful and flexible data base management system; an off-the-shelf commercial system has been incorporated.

  12. Seasonal variations of water vapor in the tropical lower statosphere

    Science.gov (United States)

    Mote, Philip W.; Rosenlof, Karen H.; Holton, James R.; Harwood, Robert S.; Waters, Joe W.

    1995-01-01

    Measurments of stratospheric water vapor by the Microwave Limb Sounder (MLS) aboard the Upper Atmosphere Research Satellite (UARS) show that in the tropical lower statosphere, low-frequency variations are closely related to the annual cycle in tropical tropopause temperatures. Tropical stratospheric air appears to retain information about the tropopause conditions it enconters for over a year as it rises through the stratosphere. A two-dimensional Lagrangian model is used to relate MLS measurements to the temperature that tropical air parcels encounter when crossing the 100 hPa surface.

  13. Climatology 2011: An MLS and Sonde Derived Ozone Climatology for Satellite Retrieval Algorithms

    Science.gov (United States)

    McPeters, Richard D.; Labow, Gordon J.

    2012-01-01

    The ozone climatology used as the a priori for the version 8 Solar Backscatter Ultraviolet (SBUV) retrieval algorithms has been updated. The Microwave Limb Sounder (MLS) instrument on Aura has excellent latitude coverage and measures ozone daily from the upper troposphere to the lower mesosphere. The new climatology consists of monthly average ozone profiles for ten degree latitude zones covering pressure altitudes from 0 to 65 km. The climatology was formed by combining data from Aura MLS (2004-2010) with data from balloon sondes (1988-2010). Ozone below 8 km (below 12 km at high latitudes) is based on balloons sondes, while ozone above 16 km (21 km at high latitudes) is based on MLS measurements. Sonde and MLS data are blended in the transition region. Ozone accuracy in the upper troposphere is greatly improved because of the near uniform coverage by Aura MLS, while the addition of a large number of balloon sonde measurements improves the accuracy in the lower troposphere, in the tropics and southern hemisphere in particular. The addition of MLS data also improves the accuracy of climatology in the upper stratosphere and lower mesosphere. The revised climatology has been used for the latest reprocessing of SBUV and TOMS satellite ozone data.

  14. Methodological examination of UAR-based change detection

    International Nuclear Information System (INIS)

    Racz, A.; Kiss, S.

    1994-07-01

    A methodological examination was performed in order to investigate the applicability of the combination of the well-known Univariate Auto Regressive (UAR) model and the classical binary Sequential Probability Ratio Testing (SPRT) method. The signal was recorded by a vibration detector fixed at a white-noise excited fuel rod. During the experiments, the following abnormality (or minor changes) were simulated: loosening of the detector, changes in the underlying system (constraints and the environment), rod impact. The residual time series were generated by an UAR model while the hypothesis testing was performed by a binary SPRT applied for checking the variation of the variance of the residual. Although the results are very promising, few disturbing effects were recognized also, which seem to be unexplained yet, therefore they need more careful application of this familiar combination. (author) 14 refs.; 21 figs.; 3 tabs

  15. UARS PEM Level 2 AXIS 1 V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The UARS Particle Environment Monitor (PEM) level 2 Atmosphere X-Ray Imaging Spectrometer (AXIS) unit 1 daily product contains the X-ray high-resolution spectral...

  16. UARS PEM Level 2 AXIS 2 V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The UARS Particle Environment Monitor (PEM) level 2 Atmosphere X-Ray Imaging Spectrometer (AXIS) unit 2 daily product contains the X-ray high-resolution spectral...

  17. A Global Climatology of Tropospheric and Stratospheric Ozone Derived from Aura OMI and MLS Measurements

    Science.gov (United States)

    Ziemke, J.R.; Chandra, S.; Labow, G.; Bhartia, P. K.; Froidevaux, L.; Witte, J. C.

    2011-01-01

    A global climatology of tropospheric and stratospheric column ozone is derived by combining six years of Aura Ozone Monitoring Instrument (OMI) and Microwave Limb Sounder (MLS) ozone measurements for the period October 2004 through December 2010. The OMI/MLS tropospheric ozone climatology exhibits large temporal and spatial variability which includes ozone accumulation zones in the tropical south Atlantic year-round and in the subtropical Mediterranean! Asia region in summer months. High levels of tropospheric ozone in the northern hemisphere also persist in mid-latitudes over the eastern North American and Asian continents extending eastward over the Pacific Ocean. For stratospheric ozone climatology from MLS, largest ozone abundance lies in the northern hemisphere in the latitude range 70degN-80degN in February-April and in the southern hemisphere around 40degS-50degS during months August-October. The largest stratospheric ozone abundances in the northern hemisphere lie over North America and eastern Asia extending eastward across the Pacific Ocean and in the southern hemisphere south of Australia extending eastward across the dateline. With the advent of many newly developing 3D chemistry and transport models it is advantageous to have such a dataset for evaluating the performance of the models in relation to dynamical and photochemical processes controlling the ozone distributions in the troposphere and stratosphere.

  18. MLS/Aura L2 Geopotential Height V003

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2GPH is the EOS Aura Microwave Limb Sounder (MLS) standard product for geopotential height derived from radiances measured by the 118 and 240 GHz radiometers. The...

  19. MLS/Aura L2 Geopotential Height V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2GPH is the EOS Aura Microwave Limb Sounder (MLS) standard product for geopotential height derived from radiances measured by the 118 and 240 GHz radiometers. The...

  20. UARS Correlative UKMO Daily Gridded Stratospheric Assimilated Data V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The UARS Correlative assimilation data from the U.K. Meteorological Office (UKMO) consists of daily model runs at 12:00 GMT as a means of providing an independent...

  1. Early data from Aura and continuity from UARS and TOMS

    NARCIS (Netherlands)

    Hilsenrath, E.; Schoeberl, M.R.; Douglass, A.R.; Bhartia, P.K.; Barnett, J.J.; Beer, R.; Waters, J.W.; Gunson, M.R.; Froidevaux, L.; Gille, J.C.; Levelt, P.F.

    2006-01-01

    Aura, the last of the large EOS observatories, was launched on July 15, 2004. Aura is designed to make comprehensive stratospheric and tropospheric composition measurements from its four instruments, HIRDLS, MLS, OMI and TES. These four instruments work in synergy to provide data on ozone trends,

  2. Multi-year assimilation of IASI and MLS ozone retrievals: variability of tropospheric ozone over the tropics in response to ENSO

    Science.gov (United States)

    Peiro, Hélène; Emili, Emanuele; Cariolle, Daniel; Barret, Brice; Le Flochmoën, Eric

    2018-05-01

    The Infrared Atmospheric Sounder Instrument (IASI) allows global coverage with very high spatial resolution and its measurements are promising for long-term ozone monitoring. In this study, Microwave Limb Sounder (MLS) O3 profiles and IASI O3 partial columns (1013.25-345 hPa) are assimilated in a chemistry transport model to produce 6-hourly analyses of tropospheric ozone for 6 years (2008-2013). We have compared and evaluated the IASI-MLS analysis and the MLS analysis to assess the added value of IASI measurements. The global chemical transport model MOCAGE (MOdèle de Chimie Atmosphérique à Grande Echelle) has been used with a linear ozone chemistry scheme and meteorological forcing fields from ERA-Interim (ECMWF global reanalysis) with a horizontal resolution of 2° × 2° and 60 vertical levels. The MLS and IASI O3 retrievals have been assimilated with a 4-D variational algorithm to constrain stratospheric and tropospheric ozone respectively. The ozone analyses are validated against ozone soundings and tropospheric column ozone (TCO) from the OMI-MLS residual method. In addition, an Ozone ENSO Index (OEI) is computed from the analysis to validate the TCO variability during the ENSO events. We show that the assimilation of IASI reproduces the variability of tropospheric ozone well during the period under study. The variability deduced from the IASI-MLS analysis and the OMI-MLS measurements are similar for the period of study. The IASI-MLS analysis can reproduce the extreme oscillation of tropospheric ozone caused by ENSO events over the tropical Pacific Ocean, although a correction is required to reduce a constant bias present in the IASI-MLS analysis.

  3. MLS/Aura L2 Hydroxyl (OH) Mixing Ratio V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2OH is the EOS Aura Microwave Limb Sounder (MLS) standard product for hydroxyl derived from radiances measured by the THz radiometer. The current version is 2.2....

  4. Design and development of a MLS based compact active suspension system, featuring air spring and energy harvesting capabilities

    DEFF Research Database (Denmark)

    Berg, Nick Ilsø; Holm, Rasmus Koldborg; Rasmussen, Peter Omand

    2016-01-01

    This paper describes the design and development of an novel Magnetic Lead Screw based active suspension system for passenger vehicles, using a new MLS topology. The design is based on performance specifications found from ISO road profiles, with a maximum harvested energy approach. By integrating...... the PMSM motor with the MLS, it possible to construct a very compact design with an integrated air spring. The prototype is build and frictional losses and efficiency for the MLS damper unit are measured. Additional the stall force and stall torque are measured for the build prototype to validate...

  5. The accuracy of remotely-sensed IWC: An assessment from MLS, TRMM and CloudSat statistics

    Science.gov (United States)

    Wu, D. L.; Heymsfield, A. J.

    2006-12-01

    Understanding climate change requires accurate global cloud ice water content (IWC) measurements. Satellite remote sensing has been the major tool to provide such global observations, but the accuracy of deduced IWC depends on knowledge of cloud microphysics learned from in-situ samples. Because only limited number and type of ice clouds have been measured by in-situ sensors, the knowledge about cloud microphysics is incomplete, and the IWC accuracy from remote sensing can vary from 30% to 200% from case to case. Recent observations from MLS, TRMM and CloudSat allow us to evaluate consistency and accuracy of IWCs deduced from passive and active satellite techniques. In this study we conduct statistical analyses on the tropical and subtropical IWCs observed by MLS, TRMM and CloudSat. The probability density functions (PDFs) of IWC are found to depend on the volume size of averaging, and therefore data need to be averaged into the same volume in order for fair comparisons. Showing measurement noise, bias and sensitivity, the PDF is a better characterization than an average for evaluating IWC accuracy because an averaged IWC depends on cloud-detection threshold that can vary from sensor to sensor. Different thresholds will not only change the average value but also change cloud fraction and occurrence frequency. Our study shows that MLS and TRMM IWCs, despite large differences in sensitivity with little overlap, can still be compared under PDF. The two statistics are generally consistent within 50% at ~13 km, obeying an approximate lognormal distribution as suggested by some ground-based radar observations. MLS has sensitivity to IWC of 1-100 mg/m3 whereas TRMM can improve its sensitivity to IWC as low as 70 mg/m3 if the radar data are averaged properly for the equivalent volume of MLS samples. The proper statistical averaging requires full characteristics of IWC noise, which are not available for products normally derived from radar reflectivity, and therefore we

  6. Observations of volcanic SO2 from MLS on Aura

    Directory of Open Access Journals (Sweden)

    H. C. Pumphrey

    2015-01-01

    Full Text Available Sulfur dioxide (SO2 is an important atmospheric constituent, particularly in the aftermath of volcanic eruptions. These events can inject large amounts of SO2 into the lower stratosphere, where it is oxidised to form sulfate aerosols; these in turn have a significant effect on the climate. The MLS instrument on the Aura satellite has observed the SO2 mixing ratio in the upper troposphere and lower stratosphere from August 2004 to the present, during which time a number of volcanic eruptions have significantly affected those regions of the atmosphere. We describe the MLS SO2 data and how various volcanic events appear in the data. As the MLS SO2 data are currently not validated we take some initial steps towards their validation. First we establish the level of internal consistency between the three spectral regions in which MLS is sensitive to SO2. We compare SO2 column values calculated from MLS data to total column values reported by the OMI instrument. The agreement is good (within about 1 DU in cases where the SO2 is clearly at altitudes above 147 hPa.

  7. MLS/Aura L2 Hydrogen Chloride (HCl) Mixing Ratio V003

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HCL is the EOS Aura Microwave Limb Sounder (MLS) standard product for hydrogen chloride derived from radiances measured primarily by the 640 GHz radiometer. The...

  8. MLS/Aura L2 Hydrogen Cyanide (HCN) Mixing Ratio V003

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HCN is the EOS Aura Microwave Limb Sounder (MLS) standard product for hydrogen cyanide derived from radiances measured primarily by the 190 GHz radiometer. The...

  9. MLS/Aura L2 Hydrogen Cyanide (HCN) Mixing Ratio V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HCN is the EOS Aura Microwave Limb Sounder (MLS) standard product for hydrogen cyanide derived from radiances measured primarily by the 190 GHz radiometer. The...

  10. MLS/Aura Level 2 Hydrogen Chloride (HCl) Mixing Ratio V004

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HCL is the EOS Aura Microwave Limb Sounder (MLS) standard product for hydrogen chloride derived from radiances measured primarily by the 640 GHz radiometer. The...

  11. MLS/Aura L2 Hypochlorous Acid (HOCL) Mixing Ratio V003

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HOCL is the EOS Aura Microwave Limb Sounder (MLS) standard product for hypochlorous acid derived from radiances measured primarily by the 640 GHz radiometer. The...

  12. MLS/Aura Level 2 Hypochlorous Acid (HOCl) Mixing Ratio V004

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HOCL is the EOS Aura Microwave Limb Sounder (MLS) standard product for hypochlorous acid derived from radiances measured primarily by the 640 GHz radiometer. The...

  13. MLS/Aura L2 Hypochlorous Acid (HOCL) Mixing Ratio V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HOCL is the EOS Aura Microwave Limb Sounder (MLS) standard product for hypochlorous acid derived from radiances measured primarily by the 640 GHz radiometer. The...

  14. Immunobiology of T cell responses to Mls-locus-disparate stimulator cells. III. Helper and cytolytic functions of cloned, Mls-reactive T cell lines

    International Nuclear Information System (INIS)

    Katz, M.E.; Tite, J.P.; Janeway, C.A. Jr.

    1986-01-01

    Mls-specific T cell clones derived by limiting dilution were tested for cytotoxic activity in a lectin-dependent 51 Cr-release assay. All the T cell clones tested were cytotoxic in such an assay in apparent contrast to previous reports (1, 2). However, only those target cells sensitive to cytolysis by other L3T4a + cytolytic T cells (3) were killed by Mls-specific T cell clones in short term 51 Cr-release assays, possibly explaining this discrepancy. All the T cell clones tested were L3T4a + ,Lyt-2 - and stimulated B cells from Mls strains of mice to proliferate and secrete immunoglobulin. Furthermore, lysis of innocent bystander targets was observed when the T cells were stimulated with Mls-disparate stimulator cells. These results are consistent with those obtained with L3T4a - T cells specific for protein antigen:self Ia and that express cytotoxic potential (3)

  15. Lagrangian Transport Calculations Using UARS Data. Part I: Passive Tracers

    Science.gov (United States)

    Manney, G. L.; Lahoz, W. A.; Harwood, R. S.; Zurek, R. W.; Kumer, J. B.; Mergenthaler, J. L.; Roche, A. E.; O'Neill, A; Swinbank, R.; Waters, J. W.

    1994-01-01

    The transport of passive tracers observed by UARS has been simulated using computed trajectories of thousands of air parcels initialized on a three-dimensional stratospheric grid. These trajectories are calculated in isentropic coordinates using horizontal winds provided by the United Kingdom Meteorological Office data assimilation system and vertical (cross-isentropic) velocities computed using a fast radiation code.

  16. MLS/Aura L2 Chlorine Monoxide (ClO) Mixing Ratio V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2CLO is the EOS Aura Microwave Limb Sounder (MLS) standard product for chlorine monoxide derived from radiances measured primarily by the 640 GHz radiometer. The...

  17. MLS/Aura L2 Nitric Acid (HNO3) Mixing Ratio V003

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HNO3 is the EOS Aura Microwave Limb Sounder (MLS) standard product for nitric acid derived from radiances measured by the 240 GHz radiometer at and below 10 hPa,...

  18. MLS/Aura Level 2 Nitric Acid (HNO3) Mixing Ratio V004

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HNO3 is the EOS Aura Microwave Limb Sounder (MLS) standard product for nitric acid derived from radiances measured by the 240 GHz radiometer at and below 10 hPa,...

  19. MLS/Aura L2 Nitric Acid (HNO3) Mixing Ratio V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HNO3 is the EOS Aura Microwave Limb Sounder (MLS) standard product for nitric acid derived from radiances measured by the 240 GHz radiometer at and below 10 hPa,...

  20. EOS MLS Lessons Learned: Design Ideas for Safer and Lower Cost Operations

    Science.gov (United States)

    Miller, Dominick

    2012-01-01

    The Earth Observing System (EOS) Microwave Limb Sounder (MLS) is a complex instrument with a front end computer and 32 subsystem computers. MLS is one of four instruments on NASA's EOS Aura spacecraft With almost 8 years in orbit, MLS has a few lessons learned which can be applied during the design phase of future instruments to effect better longevity, more robust operations and a significant cost benefit during operations phase.

  1. Relativistic Electrons Observed at UARS and the Interpretation of their Storm-Associated Intensity Variations

    Science.gov (United States)

    Pesnell, W. D.; Goldberg, R. A.; Chenette, D. L.; Gaines, E. E.

    1999-01-01

    The High Energy Particle Spectrometer (HEPS) instrument on the Upper Atmosphere Research Satellite (UARS) provides a database of electron intensities well resolved in energy and pitch-angle. Because of its 57 deg. orbital inclination, UARS encounters with magnetic shells L greater than 2 occur quite far off-equator (B/B (sub 0) greater than 9), corresponding to equatorial pitch angle alpha (sub 0) greater than 20 deg. Data acquired by HEPS (October 1991 through September 1994) span the declining phase of Solar Cycle 22. To reveal the storm-associated time dependence of relativistic electron intensities over the wide range of energies (50 keV to 5 MeV) covered by HEPS, we divide the daily average of the measured spectrum at a given L value (bin width = 0.25) by the corresponding 500-day average and plot the results with a color scale that spans only 2.5 decades. The data show that our off-equatorial electron intensities typically increase with time after the end of recovery phase (not during main phase or recovery phase) of each geomagnetic storm. The delay in off-equatorial energetic electron response and the subsequent lifetime of the corresponding electron flux enhancement seem to increase with particle energy above 300 keV. The trend below 300 keV seems to be opposite, such that the delay varies inversely with electron energy. Our working hypothesis for interpretation is that stormtime radial transport tends to increase the phase-space densities of trapped relativistic electrons but typically leads to a flux increases at specified energies only as the current (as indicated by Dst) decays. Flux enhancements in early recovery phase are greatest for equatorially mirroring electrons, and to pitch-angle anisotropies are initially large. Subsequent pitch-angle diffusion broadens the flux enhancement to particles that mirror off equator, thus gradually increasing low-altitude electron intensities (as detected by HEPS/UARS) on time scales equal to about 20% of

  2. UARS Correlative UKMO Daily Gridded Stratospheric Assimilated Data V001 (UARZCUKM) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The UARS Correlative assimilation data from the U.K. Meteorological Office (UKMO) consists of daily model runs at 12:00 GMT as a means of providing an independent...

  3. Lagrangian Transport Calculations Using UARS Data. Part 2; Ozone

    Science.gov (United States)

    Manney, Gloria L.; Zurek, R. W.; Froidevaux, L.; Waters, J. W.; ONeill, A.; Swinbank, R.

    1995-01-01

    Trajectory calculations are used to examine ozone transport in the polar winter stratosphere during periods of the Upper Atmosphere Research Satellite (UARS) observations. The value of these calculations for determining mass transport was demonstrated previously using UARS observations of long-lived tracers, In the middle stratosphere, the overall ozone behavior observed by the Microwave Limb Sounder in the polar vortex is reproduced by this purely dynamical model. Calculations show the evolution of ozone in the lower stratosphere during early winter to be dominated by dynamics in December 1992 in the Arctic. Calculations for June 1992 in the Antarctic show evidence of chemical ozone destruction and indicate that approx. 50% of the chemical destruction may be masked by dynamical effects, mainly diabatic descent, which bring higher ozone into the lower-stratospheric vortex. Estimating differences between calculated and observed fields suggests that dynamical changes masked approx. 20% - 35% of chemical ozone loss during late February and early March 1993 in the Arctic. In the Antarctic late winter, in late August and early September 1992, below approx. 520 K, the evolution of vortex-averaged ozone is entirely dominated by chemical effects; above this level, however, chemical ozone depletion can be partially or completely masked by dynamical effects. Our calculations for 1992 showed that chemical loss was nearly completely compensated by increases due to diabatic descent at 655 K.

  4. MLS/Aura Level 2 Nitrous Oxide (N2O) Mixing Ratio V004

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2N2O is the EOS Aura Microwave Limb Sounder (MLS) standard product for nitrous oxide derived from radiances measured primarily by the 640 GHz radiometer (Band 12)...

  5. UARS PEM Level 2 AXIS 2 V001 (UARPE2AXIS2) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The UARS Particle Environment Monitor (PEM) level 2 Atmosphere X-Ray Imaging Spectrometer (AXIS) unit 2 daily product contains the X-ray high-resolution spectral...

  6. UARS PEM Level 2 AXIS 1 V001 (UARPE2AXIS1) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The UARS Particle Environment Monitor (PEM) level 2 Atmosphere X-Ray Imaging Spectrometer (AXIS) unit 1 daily product contains the X-ray high-resolution spectral...

  7. ACE-FTS ozone, water vapour, nitrous oxide, nitric acid, and carbon monoxide profile comparisons with MIPAS and MLS

    Science.gov (United States)

    Sheese, Patrick E.; Walker, Kaley A.; Boone, Chris D.; Bernath, Peter F.; Froidevaux, Lucien; Funke, Bernd; Raspollini, Piera; von Clarmann, Thomas

    2017-01-01

    The atmospheric limb sounders, ACE-FTS on the SCISAT satellite, MIPAS on ESA's Envisat satellite, and MLS on NASA's Aura satellite, take measurements used to retrieve atmospheric profiles of O3, N2O, H2O, HNO3, and CO. Each was taking measurements between February 2004 and April 2012 (ACE-FTS and MLS are currently operational), providing hundreds of profile coincidences in the Northern and Southern hemispheres, and during local morning and evening. Focusing on determining diurnal and hemispheric biases in the ACE-FTS data, this study compares ACE-FTS version 3.5 profiles that are collocated with MIPAS and MLS, and analyzes the differences between instrument retrievals for Northern and Southern hemispheres and for local morning and evening data. For O3, ACE-FTS is typically within ±5% of mid-stratospheric MIPAS and MLS data and exhibits a positive bias of 10 to 20% in the upper stratosphere - lower mesosphere. For H2O, ACE-FTS exhibits an average bias of -5% between 20 and 60 km. For N2O, ACE-FTS agrees with MIPAS and MLS within -20 to +10% up to 45 km and 35 km, respectively. For HNO3, ACE-FTS typically agrees within ±10% below 30 km, and exhibits a positive bias of 10 to 20% above 30 km. With respect to MIPAS CO, ACE-FTS exhibits an average -11% bias between 28 and 50 km, and at higher altitudes a positive bias on the order of 10% (>100%) in the winter (summer). With respect to winter MLS CO, ACE-FTS is typically within ±10% between 25 and 40 km, and has an average bias of -11% above 40 km.

  8. EOS MLS Level 1B Data Processing Software. Version 3

    Science.gov (United States)

    Perun, Vincent S.; Jarnot, Robert F.; Wagner, Paul A.; Cofield, Richard E., IV; Nguyen, Honghanh T.; Vuu, Christina

    2011-01-01

    This software is an improvement on Version 2, which was described in EOS MLS Level 1B Data Processing, Version 2.2, NASA Tech Briefs, Vol. 33, No. 5 (May 2009), p. 34. It accepts the EOS MLS Level 0 science/engineering data, and the EOS Aura spacecraft ephemeris/attitude data, and produces calibrated instrument radiances and associated engineering and diagnostic data. This version makes the code more robust, improves calibration, provides more diagnostics outputs, defines the Galactic core more finely, and fixes the equator crossing. The Level 1 processing software manages several different tasks. It qualifies each data quantity using instrument configuration and checksum data, as well as data transmission quality flags. Statistical tests are applied for data quality and reasonableness. The instrument engineering data (e.g., voltages, currents, temperatures, and encoder angles) is calibrated by the software, and the filter channel space reference measurements are interpolated onto the times of each limb measurement with the interpolates being differenced from the measurements. Filter channel calibration target measurements are interpolated onto the times of each limb measurement, and are used to compute radiometric gain. The total signal power is determined and analyzed by each digital autocorrelator spectrometer (DACS) during each data integration. The software converts each DACS data integration from an autocorrelation measurement in the time domain into a spectral measurement in the frequency domain, and estimates separately the spectrally, smoothly varying and spectrally averaged components of the limb port signal arising from antenna emission and scattering effects. Limb radiances are also calibrated.

  9. A Strategy for an MLS Workflow Management System

    National Research Council Canada - National Science Library

    Kang, Myong H; Froscher, Judith N; Eppinger, Brian J; Moskowitz, Ira S

    1999-01-01

    .... Therefore, DoD needs MLS workflow management systems (WFMS) to enable globally distributed users and existing applications to cooperate across classification domains to achieve mission critical goals...

  10. A cloud-ozone data product from Aura OMI and MLS satellite measurements

    Directory of Open Access Journals (Sweden)

    J. R. Ziemke

    2017-11-01

    Full Text Available Ozone within deep convective clouds is controlled by several factors involving photochemical reactions and transport. Gas-phase photochemical reactions and heterogeneous surface chemical reactions involving ice, water particles, and aerosols inside the clouds all contribute to the distribution and net production and loss of ozone. Ozone in clouds is also dependent on convective transport that carries low-troposphere/boundary-layer ozone and ozone precursors upward into the clouds. Characterizing ozone in thick clouds is an important step for quantifying relationships of ozone with tropospheric H2O, OH production, and cloud microphysics/transport properties. Although measuring ozone in deep convective clouds from either aircraft or balloon ozonesondes is largely impossible due to extreme meteorological conditions associated with these clouds, it is possible to estimate ozone in thick clouds using backscattered solar UV radiation measured by satellite instruments. Our study combines Aura Ozone Monitoring Instrument (OMI and Microwave Limb Sounder (MLS satellite measurements to generate a new research product of monthly-mean ozone concentrations in deep convective clouds between 30° S and 30° N for October 2004–April 2016. These measurements represent mean ozone concentration primarily in the upper levels of thick clouds and reveal key features of cloud ozone including: persistent low ozone concentrations in the tropical Pacific of  ∼ 10 ppbv or less; concentrations of up to 60 pphv or greater over landmass regions of South America, southern Africa, Australia, and India/east Asia; connections with tropical ENSO events; and intraseasonal/Madden–Julian oscillation variability. Analysis of OMI aerosol measurements suggests a cause and effect relation between boundary-layer pollution and elevated ozone inside thick clouds over landmass regions including southern Africa and India/east Asia.

  11. Methodological examination of UAR-based change detection

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A.; Kiss, S. [Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics

    1995-12-01

    A methodological examination was performed in order to investigate the applicability of the combination of the well-known Univariate AutoRegressive model and the classical binary SPRT method. The signal was recorded by a vibration detector fixed at a white-noise excited fuel rod. During the experiments, the following abnormality (or minor changes) were simulated: loosening of the detector, changes in the underlying system (constraints and the environment), rod impact. The residual time series were generated by an UAR model while the hypothesis testing was performed by a binary SPRT applied for checking the variation of the variance of the residual. Although the results are very promising, few disturbing effects were recognized also, which are as yet unexplained, therefore more careful application of this familiar combination is required. (author).

  12. Assimilation of stratospheric ozone in the chemical transport model STRATAQ

    Directory of Open Access Journals (Sweden)

    B. Grassi

    2004-09-01

    Full Text Available We describe a sequential assimilation approach useful for assimilating tracer measurements into a three-dimensional chemical transport model (CTM of the stratosphere. The numerical code, developed largely according to Kha00, uses parameterizations and simplifications allowing assimilation of sparse observations and the simultaneous evaluation of analysis errors, with reasonable computational requirements. Assimilation parameters are set by using χ2 and OmF (Observation minus Forecast statistics. The CTM used here is a high resolution three-dimensional model. It includes a detailed chemical package and is driven by UKMO (United Kingdom Meteorological Office analyses. We illustrate the method using assimilation of Upper Atmosphere Research Satellite/Microwave Limb Sounder (UARS/MLS ozone observations for three weeks during the 1996 antarctic spring. The comparison of results from the simulations with TOMS (Total Ozone Mapping Spectrometer measurements shows improved total ozone fields due to assimilation of MLS observations. Moreover, the assimilation gives indications on a possible model weakness in reproducing polar ozone values during springtime.

  13. Assimilation of stratospheric ozone in the chemical transport model STRATAQ

    Directory of Open Access Journals (Sweden)

    B. Grassi

    2004-09-01

    Full Text Available We describe a sequential assimilation approach useful for assimilating tracer measurements into a three-dimensional chemical transport model (CTM of the stratosphere. The numerical code, developed largely according to Kha00, uses parameterizations and simplifications allowing assimilation of sparse observations and the simultaneous evaluation of analysis errors, with reasonable computational requirements. Assimilation parameters are set by using χ2 and OmF (Observation minus Forecast statistics. The CTM used here is a high resolution three-dimensional model. It includes a detailed chemical package and is driven by UKMO (United Kingdom Meteorological Office analyses. We illustrate the method using assimilation of Upper Atmosphere Research Satellite/Microwave Limb Sounder (UARS/MLS ozone observations for three weeks during the 1996 antarctic spring. The comparison of results from the simulations with TOMS (Total Ozone Mapping Spectrometer measurements shows improved total ozone fields due to assimilation of MLS observations. Moreover, the assimilation gives indications on a possible model weakness in reproducing polar ozone values during springtime.

  14. Graph SLAM correction for single scanner MLS forest data under boreal forest canopy

    Science.gov (United States)

    Kukko, Antero; Kaijaluoto, Risto; Kaartinen, Harri; Lehtola, Ville V.; Jaakkola, Anttoni; Hyyppä, Juha

    2017-10-01

    Mobile laser scanning (MLS) provides kinematic means to collect three dimensional data from surroundings for various mapping and environmental analysis purposes. Vehicle based MLS has been used for road and urban asset surveys for about a decade. The equipment to derive the trajectory information for the point cloud generation from the laser data is almost without exception based on GNSS-IMU (Global Navigation Satellite System - Inertial Measurement Unit) technique. That is because of the GNSS ability to maintain global accuracy, and IMU to produce the attitude information needed to orientate the laser scanning and imaging sensor data. However, there are known challenges in maintaining accurate positioning when GNSS signal is weak or even absent over long periods of time. The duration of the signal loss affects the severity of degradation of the positioning solution depending on the quality/performance level of the IMU in use. The situation could be improved to a certain extent with higher performance IMUs, but increasing system expenses make such approach unsustainable in general. Another way to tackle the problem is to attach additional sensors to the system to overcome the degrading position accuracy: such that observe features from the environment to solve for short term system movements accurately enough to prevent the IMU solution to drift. This results in more complex system integration with need for more calibration and synchronization of multiple sensors into an operational approach. In this paper we study operation of an ATV (All -terrain vehicle) mounted, GNSS-IMU based single scanner MLS system in boreal forest conditions. The data generated by RoamerR2 system is targeted for generating 3D terrain and tree maps for optimizing harvester operations and forest inventory purposes at individual tree level. We investigate a process-flow and propose a graph optimization based method which uses data from a single scanner MLS for correcting the post

  15. Space-Time Variations in Water Vapor as Observed by the UARS Microwave Limb Sounder

    Science.gov (United States)

    Elson, Lee S.; Read, William G.; Waters, Joe W.; Mote, Philip W.; Kinnersley, Jonathan S.; Harwood, Robert S.

    1996-01-01

    Water vapor in the upper troposphere has a significant impact on the climate system. Difficulties in making accurate global measurements have led to uncertainty in understanding water vapor's coupling to the hydrologic cycle in the lower troposphere and its role in radiative energy balance. The Microwave Limb Sounder (MLS) on the Upper Atmosphere Research Satellite is able to retrieve water vapor concentration in the upper troposphere with good sensitivity and nearly global coverage. An analysis of these preliminary retrievals based on 3 years of observations shows the water vapor distribution to be similar to that measured by other techniques and to model results. The primary MLS water vapor measurements were made in the stratosphere, where this species acts as a conserved tracer under certain conditions. As is the case for the upper troposphere, most of the stratospheric discussion focuses on the time evolution of the zonal mean and zonally varying water vapor. Stratospheric results span a 19-month period and tropospheric results a 36-month period, both beginning in October of 1991. Comparisons with stratospheric model calculations show general agreement, with some differences in the amplitude and phase of long-term variations. At certain times and places, the evolution of water vapor distributions in the lower stratosphere suggests the presence of meridional transport.

  16. EOS MLS Level 1B Data Processing, Version 2.2

    Science.gov (United States)

    Perun, Vincent; Jarnot, Robert; Pickett, Herbert; Cofield, Richard; Schwartz, Michael; Wagner, Paul

    2009-01-01

    A computer program performs level- 1B processing (the term 1B is explained below) of data from observations of the limb of the Earth by the Earth Observing System (EOS) Microwave Limb Sounder (MLS), which is an instrument aboard the Aura spacecraft. This software accepts, as input, the raw EOS MLS scientific and engineering data and the Aura spacecraft ephemeris and attitude data. Its output consists of calibrated instrument radiances and associated engineering and diagnostic data. [This software is one of several computer programs, denoted product generation executives (PGEs), for processing EOS MLS data. Starting from level 0 (representing the aforementioned raw data, the PGEs and their data products are denoted by alphanumeric labels (e.g., 1B and 2) that signify the successive stages of processing.] At the time of this reporting, this software is at version 2.2 and incorporates improvements over a prior version that make the code more robust, improve calibration, provide more diagnostic outputs, improve the interface with the Level 2 PGE, and effect a 15-percent reduction in file sizes by use of data compression.

  17. MLS/Aura Level 2 Hypochlorous Acid (HOCl) Mixing Ratio V003 (ML2HOCL) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HOCL is the EOS Aura Microwave Limb Sounder (MLS) standard product for hypochlorous acid derived from radiances measured primarily by the 640 GHz radiometer. The...

  18. Assessment and Applications of NASA Ozone Data Products Derived from Aura OMI-MLS Satellite Measurements in Context of the GMI Chemical Transport Model

    Science.gov (United States)

    Ziemke, J. R.; Olsen, M. A.; Witte, J. C.; Douglass, A. R.; Strahan, S. E.; Wargan, K.; Liu, X.; Schoeberl, M. R.; Yang, K.; Kaplan, T. B.; hide

    2013-01-01

    Measurements from the Ozone Monitoring Instrument (OMI) and Microwave Limb Sounder (MLS), both onboard the Aura spacecraft, have been used to produce daily global maps of column and profile ozone since August 2004. Here we compare and evaluate three strategies to obtain daily maps of tropospheric and stratospheric ozone from OMI and MLS measurements: trajectory mapping, direct profile retrieval, and data assimilation. Evaluation is based upon an assessment that includes validation using ozonesondes and comparisons with the Global Modeling Initiative (GMI) chemical transport model (CTM). We investigate applications of the three ozone data products from near-decadal and inter-annual timescales to day-to-day case studies. Zonally averaged inter-annual changes in tropospheric ozone from all of the products in any latitude range are of the order 1-2 Dobson Units while changes (increases) over the 8-year Aura record investigated http://eospso.gsfc.nasa.gov/atbd-category/49 vary approximately 2-4 Dobson Units. It is demonstrated that all of the ozone products can measure and monitor exceptional tropospheric ozone events including major forest fire and pollution transport events. Stratospheric ozone during the Aura record has several anomalous inter-annual events including stratospheric warming split events in the Northern Hemisphere extra-tropics that are well captured using the data assimilation ozone profile product. Data assimilation with continuous daily global coverage and vertical ozone profile information is the best of the three strategies at generating a global tropospheric and stratospheric ozone product for science applications.

  19. Experimental immunologically mediated aplastic anemia (AA) in H-2k identical, Mls (M) locus different mice

    Energy Technology Data Exchange (ETDEWEB)

    Knospe, W.H.; Steinberg, D.; Speck, B.

    1983-07-01

    Immunologically mediated aplastic anemia (AA) was experimentally induced in mice by injecting 10(7) lymph node cells (LNC) from donor mice of one inbred strain to another H-2k identical but Mls mismatched strain previously given 600 rad total body gamma irradiation (TBI). AA developed after 2 weeks to 6 months in selected strain combinations used and usually 60 to 90% of the mice died. Clinical signs of graft-versus-host disease did not occur and splenic atrophy rather than splenomegaly was the rule. Histologically these mice had a lesion of the hematopoietic microenvironment characterized by sinusoidal injury and stromal necrosis. Others have demonstrated injury to hematopoietic stem cells. C3H/He LNC induced AA whereas C3H/HeJ LNC failed to induce AA. The C3H/HeJ strain carries a macrophage defect and these results suggest that a macrophage-like cell may be a mediator of immunological injury in this experimental model. Although all strain combinations evaluated were H-2k identical and Mls mismatched, certain Mls combinations resulted in AA and identical Mls mismatched but different strains did not. Both strong (Mlsd) and weak (Mlsc) stimulating LNC induce AA but simple Mls differences do not explain the AA as similar Mls combinations but different strain combinations fail to induce AA.

  20. Registration of TLS and MLS Point Cloud Combining Genetic Algorithm with ICP

    Directory of Open Access Journals (Sweden)

    YAN Li

    2018-04-01

    Full Text Available Large scene point cloud can be quickly acquired by mobile laser scanning (MLS technology,which needs to be supplemented by terrestrial laser scanning (TLS point cloud because of limited field of view and occlusion.MLS and TLS point cloud are located in geodetic coordinate system and local coordinate system respectively.This paper proposes an automatic registration method combined genetic algorithm (GA and iterative closed point ICP to achieve a uniform coordinate reference frame.The local optimizer is utilized in ICP.The efficiency of ICP is higher than that of GA registration,but it depends on a initial solution.GA is a global optimizer,but it's inefficient.The combining strategy is that ICP is enabled to complete the registration when the GA tends to local search.The rough position measured by a built-in GPS of a terrestrial laser scanner is used in the GA registration to limit its optimizing search space.To improve the GA registration accuracy,a maximum registration model called normalized sum of matching scores (NSMS is presented.The results for measured data show that the NSMS model is effective,the root mean square error (RMSE of GA registration is 1~5 cm and the registration efficiency can be improved by about 50% combining GA with ICP.

  1. Comparison of the Changes in the Visible and Infrared Irradiance Observed by the SunPhotometers on EURECA to the UARS Total Solar and UV Irradiances

    Science.gov (United States)

    Pap, Judit

    1995-01-01

    Solar irradiance in the near-UV (335 nm), visible (500 nm) and infrared (778 nm) spectral bands has been measured by the SunPhotometers developed at the World Radiation Center, Davos, Switzerland on board the European Retrievable Carrier between August 1992 and May 1993. Study of the variations in the visible and infrared irradiance is important for both solar and atmospheric physics. The purpose of this paper is to examine the temporal variations observed in the visible and infrared spectral bands after eliminating the trend in the data mainly related to instrument degradation. The effect of active regions in these spectral irradiances is clearly resolved. Variations in the visible and infrared irradiances are compared to total solar irradiance observed by the SOVA2 radiometer on the EURECA platform and by the ACRIMII radiometer on UARS as well as to UV observations of the UARS and NOAA9 satellites. The space-borne spectral irradiance observations are compared to the photometric sunspot deficit and CaII K irradiance measured at the San Fernando Observatory, California State University at Northridge in order to study the effect of active regions in detail.

  2. The Upper Atmosphere Research Satellite: From Coffee Table Art to Quantitative Science

    Science.gov (United States)

    Douglass, Anne R.

    1999-01-01

    The Upper Atmosphere Research Satellite (UARS) has provided an unprecedented set of observations of constituents of the stratosphere. When used in combination with data from other sources and appropriate modeling tools, these observations are useful for quantitative evaluation of stratospheric photochemical processes. This is illustrated by comparing ozone observations from airborne Differential Absorption Lidar (DIAL), from the Polar Ozone and Aerosol Measurement (POAM), from the Microwave Limb Sounder (MLS), and from the Halogen occultation Experiment (HALOE) with ozone fields generated with a three dimensional model. For 1995-96, at polar latitudes, observations from DIAL flights on December 9 and January 30, and POAM and MLS between late December and late January are compared with ozone fields from the GSFC 3D chemistry and transport model. Data from the three platforms consistently show that the observed ozone has a negative trend relative to the modeled ozone, and that the trend is uniform in time between early and mid winter, with no obvious dependence on proximity to the vortex edge. The importance of chlorine catalyzed photochemistry to this ozone loss is explored by comparing observations from MLS and HALOE with simulations for other northern winters, particularly 1997-98.

  3. Processing EOS MLS Level-2 Data

    Science.gov (United States)

    Snyder, W. Van; Wu, Dong; Read, William; Jiang, Jonathan; Wagner, Paul; Livesey, Nathaniel; Schwartz, Michael; Filipiak, Mark; Pumphrey, Hugh; Shippony, Zvi

    2006-01-01

    A computer program performs level-2 processing of thermal-microwave-radiance data from observations of the limb of the Earth by the Earth Observing System (EOS) Microwave Limb Sounder (MLS). The purpose of the processing is to estimate the composition and temperature of the atmosphere versus altitude from .8 to .90 km. "Level-2" as used here is a specialists f term signifying both vertical profiles of geophysical parameters along the measurement track of the instrument and processing performed by this or other software to generate such profiles. Designed to be flexible, the program is controlled via a configuration file that defines all aspects of processing, including contents of state and measurement vectors, configurations of forward models, measurement and calibration data to be read, and the manner of inverting the models to obtain the desired estimates. The program can operate in a parallel form in which one instance of the program acts a master, coordinating the work of multiple slave instances on a cluster of computers, each slave operating on a portion of the data. Optionally, the configuration file can be made to instruct the software to produce files of simulated radiances based on state vectors formed from sets of geophysical data-product files taken as input.

  4. MLS student active learning within a "cloud" technology program.

    Science.gov (United States)

    Tille, Patricia M; Hall, Heather

    2011-01-01

    In November 2009, the MLS program in a large public university serving a geographically large, sparsely populated state instituted an initiative for the integration of technology enhanced teaching and learning within the curriculum. This paper is intended to provide an introduction to the system requirements and sample instructional exercises used to create an active learning technology-based classroom. Discussion includes the following: 1.) define active learning and the essential components, 2.) summarize teaching methods, technology and exercises utilized within a "cloud" technology program, 3.) describe a "cloud" enhanced classroom and programming 4.) identify active learning tools and exercises that can be implemented into laboratory science programs, and 5.) describe the evaluation and assessment of curriculum changes and student outcomes. The integration of technology in the MLS program is a continual process and is intended to provide student-driven active learning experiences.

  5. MLS/Aura Level 2 Diagnostics, Geophysical Parameter Grid V004

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2DGG is the EOS Aura Microwave Limb Sounder (MLS) product containing geophysical diagnostic quantities pertaining directly to the standard geophysical data...

  6. Models for estimating runway landing capacity with Microwave Landing System (MLS)

    Science.gov (United States)

    Tosic, V.; Horonjeff, R.

    1975-01-01

    A model is developed which is capable of computing the ultimate landing runway capacity, under ILS and MLS conditions, when aircraft population characteristics and air traffic control separation rules are given. This model can be applied in situations when only a horizontal separation between aircraft approaching a runway is allowed, as well as when both vertical and horizontal separations are possible. It is assumed that the system is free of errors, that is that aircraft arrive at specified points along the prescribed flight path precisely when the controllers intend for them to arrive at these points. Although in the real world there is no such thing as an error-free system, the assumption is adequate for a qualitative comparison of MLS with ILS. Results suggest that an increase in runway landing capacity, caused by introducing the MLS multiple approach paths, is to be expected only when an aircraft population consists of aircraft with significantly differing approach speeds and particularly in situations when vertical separation can be applied. Vertical separation can only be applied if one of the types of aircraft in the mix has a very steep descent angle.

  7. MLS/Aura Level 2 Nitric Acid (HNO3) Mixing Ratio V003 (ML2HNO3) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HNO3 is the EOS Aura Microwave Limb Sounder (MLS) standard product for nitric acid derived from radiances measured by the 240 GHz radiometer at and below 10 hPa,...

  8. MLS/Aura Level 2 Nitric Acid (HNO3) Mixing Ratio V004 (ML2HNO3) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HNO3 is the EOS Aura Microwave Limb Sounder (MLS) standard product for nitric acid derived from radiances measured by the 240 GHz radiometer at and below 10 hPa,...

  9. Thermal tides and studies to tune the mechanistic tidal model using UARS observations

    Directory of Open Access Journals (Sweden)

    V. A. Yudin

    1997-09-01

    Full Text Available Monthly simulations of the thermal diurnal and semidiurnal tides are compared to High-Resolution Doppler Imager (HRDI and Wind Imaging Interferometer (WINDII wind and temperature measurements on the Upper-Atmosphere Research Satellite (UARS. There is encouraging agreement between the observations and the linear global mechanistic tidal model results both for the diurnal and semidiurnal components in the equatorial and mid-latitude regions. This gives us the confidence to outline the first steps of an assimilative analysis/interpretation for tides, dissipation, and mean flow using a combination of model results and the global measurements from HRDI and WINDII. The sensitivity of the proposed technique to the initial guess employed to obtain a best fit to the data by tuning model parameters is discussed for the January and March 1993 cases, when the WINDII day and night measurements of the meridional winds between 90 and 110 km are used along with the daytime HRDI measurements. Several examples for the derivation of the tidal variables and decomposition of the measured winds into tidal and mean flow components using this approach are compared with previous tidal estimates and modeling results for the migrating tides. The seasonal cycle of the derived diurnal tidal amplitudes are discussed and compared with radar observation between 80 and 100 km and 40°S and 40°N.

  10. Thermal tides and studies to tune the mechanistic tidal model using UARS observations

    Directory of Open Access Journals (Sweden)

    V. A. Yudin

    Full Text Available Monthly simulations of the thermal diurnal and semidiurnal tides are compared to High-Resolution Doppler Imager (HRDI and Wind Imaging Interferometer (WINDII wind and temperature measurements on the Upper-Atmosphere Research Satellite (UARS. There is encouraging agreement between the observations and the linear global mechanistic tidal model results both for the diurnal and semidiurnal components in the equatorial and mid-latitude regions. This gives us the confidence to outline the first steps of an assimilative analysis/interpretation for tides, dissipation, and mean flow using a combination of model results and the global measurements from HRDI and WINDII. The sensitivity of the proposed technique to the initial guess employed to obtain a best fit to the data by tuning model parameters is discussed for the January and March 1993 cases, when the WINDII day and night measurements of the meridional winds between 90 and 110 km are used along with the daytime HRDI measurements. Several examples for the derivation of the tidal variables and decomposition of the measured winds into tidal and mean flow components using this approach are compared with previous tidal estimates and modeling results for the migrating tides. The seasonal cycle of the derived diurnal tidal amplitudes are discussed and compared with radar observation between 80 and 100 km and 40°S and 40°N.

  11. Automatic Rail Extraction and Celarance Check with a Point Cloud Captured by Mls in a Railway

    Science.gov (United States)

    Niina, Y.; Honma, R.; Honma, Y.; Kondo, K.; Tsuji, K.; Hiramatsu, T.; Oketani, E.

    2018-05-01

    Recently, MLS (Mobile Laser Scanning) has been successfully used in a road maintenance. In this paper, we present the application of MLS for the inspection of clearance along railway tracks of West Japan Railway Company. Point clouds around the track are captured by MLS mounted on a bogie and rail position can be determined by matching the shape of the ideal rail head with respect to the point cloud by ICP algorithm. A clearance check is executed automatically with virtual clearance model laid along the extracted rail. As a result of evaluation, the accuracy of extracting rail positions is less than 3 mm. With respect to the automatic clearance check, the objects inside the clearance and the ones related to a contact line is successfully detected by visual confirmation.

  12. A two dimensional code (R,Z) for nuclear reactor analysis and its application to the UAR-RI reactor

    International Nuclear Information System (INIS)

    Bishay, S.T.; Mikhail, I.F.I.; Gaafar, M.A.; Michaiel, M.L.; Nassar, S.F.

    1988-01-01

    A detailed study is given of fuel consumption in completely reflected cylindrical reactors. A two group, two dimensional (r,z) code is developed to carry out the required procedure. The code is applied to the UAR-RI reactor and the results are found to be in complete agreement with the experimental observations and with the theoretical interpretations. 7 fig., 12 tab

  13. Educational Requirements beyond the MLS for Academic Librarians in 1990.

    Science.gov (United States)

    Aufderhaar, Kathleen E.

    Eight-hundred sixty-five advertisements for academic librarian positions in the 1990 issues of "American Libraries" were examined to determine how many position advertisements were asking for advanced degrees in addition to the MLS. Data from the 231 advertisements asking for advanced degrees were compared with data from previous studies as well…

  14. Comparison of CMAM simulations of carbon monoxide (CO, nitrous oxide (N2O, and methane (CH4 with observations from Odin/SMR, ACE-FTS, and Aura/MLS

    Directory of Open Access Journals (Sweden)

    B. Barret

    2009-05-01

    Full Text Available Simulations of CO, N2O and CH4 from a coupled chemistry-climate model (CMAM are compared with satellite measurements from Odin Sub-Millimeter Radiometer (Odin/SMR, Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS, and Aura Microwave Limb Sounder (Aura/MLS. Pressure-latitude cross-sections and seasonal time series demonstrate that CMAM reproduces the observed global CO, N2O, and CH4 distributions quite well. Generally, excellent agreement with measurements is found between CO simulations and observations in the stratosphere and mesosphere. Differences between the simulations and the ACE-FTS observations are generally within 30%, and the differences between CMAM results and SMR and MLS observations are slightly larger. These differences are comparable with the difference between the instruments in the upper stratosphere and mesosphere. Comparisons of N2O show that CMAM results are usually within 15% of the measurements in the lower and middle stratosphere, and the observations are close to each other. However, the standard version of CMAM has a low N2O bias in the upper stratosphere. The CMAM CH4 distribution also reproduces the observations in the lower stratosphere, but has a similar but smaller negative bias in the upper stratosphere. The negative bias may be due to that the gravity drag is not fully resolved in the model. The simulated polar CO evolution in the Arctic and Antarctic agrees with the ACE and MLS observations. CO measurements from 2006 show evidence of enhanced descent of air from the mesosphere into the stratosphere in the Arctic after strong stratospheric sudden warmings (SSWs. CMAM also shows strong descent of air after SSWs. In the tropics, CMAM captures the annual oscillation in the lower stratosphere and the semiannual oscillations at the stratopause and mesopause seen in Aura/MLS CO and N2O observations and in Odin/SMR N2O observations. The Odin/SMR and Aura/MLS N2O observations also show a quasi

  15. Flight evaluations of approach/landing navigation sensor systems. MLS to kohokei hiko jikken. ; 1990 nendo no jikken gaiyo

    Energy Technology Data Exchange (ETDEWEB)

    1992-07-01

    Flight test results of such navigation sensor systems as MLS (microwave landing system), GPS(global positioning system) and INS (inertial navigation system) on the Dornier-228 research aircraft in 1990 were reported, which tests have being promoted by National Aerospace Laboratory (NAL), Japan to develop unmanned approach/landing (A/L) navigation sensor systems for the future spaceplane HOPE. The measured data corresponding to a WGS84 (world geodetic system 1984) navigation coordinate system were evaluated, and the reference orbit was also prepared by laser tracker analysis. The navigation sensor systems such as MLS were evaluated on the basis of CMN (control motion noise) or PFE (path following error), and preliminary calculation was also conducted for a GPS-INS hybrid system. As experimental results, several data were gathered for each sensor system resulting in possible data comparison between the sensor systems, and the feasibility of the GPS-INS hybrid system was also confirmed. 35 refs., 49 figs., 22 tabs.

  16. SMLTM simulations of the diurnal tide: comparison with UARS observations

    Directory of Open Access Journals (Sweden)

    R. A. Akmaev

    1997-09-01

    Full Text Available Wind and temperature observations in the mesosphere and lower thermosphere (MLT from the Upper Atmosphere Research Satellite (UARS reveal strong seasonal variations of tides, a dominant component of the MLT dynamics. Simulations with the Spectral mesosphere/lower thermosphere model (SMLTM for equinox and solstice conditions are presented and compared with the observations. The diurnal tide is generated by forcing specified at the model lower boundary and by in situ absorption of solar radiation. The model incorporates realistic parameterizations of physical processes including various dissipation processes important for propagation of tidal waves in the MLT. A discrete multi-component gravity-wave parameterization has been modified to account for seasonal variations of the background temperature. Eddy diffusion is calculated depending on the gravity-wave energy deposition rate and stability of the background flow. It is shown that seasonal variations of the diurnal-tide amplitudes are consistent with observed variations of gravity-wave sources in the lower atmosphere.

  17. The effect of MLS laser radiation on cell lipid membrane.

    Science.gov (United States)

    Pasternak, Kamila; Wróbel, Dominika; Nowacka, Olga; Pieszyński, Ireneusz; Bryszewska, Maria; Kujawa, Jolanta

    2018-03-14

    Authors of numerous publications have proved the therapeutic effect of laser irradiation on biological material, but the mechanisms at cellular and subcellular level are not yet well understood. The aim of this study was to assess the effect of laser radiation emitted by the MLS M1 system (Multiwave Locked System) at two wavelengths (808 nm continuous and 905 nm pulsed) on the stability and fluidity of liposomes with a lipid composition similar to that of human erythrocyte membrane or made of phosphatidylocholine. Liposomes were exposed to low-energy laser radiation at surface densities 195 mW/cm2 (frequency 1,000 Hz) and 230 mW/cm2 (frequency 2,000 Hz). Different doses of radiation energy in the range 0-15 J were applied. The surface energy density was within the range 0.46 - 4.9 J/cm 2. The fluidity and stability of liposomes subjected to such irradiation changed depending on the parameters of radiation used. Since MLS M1 laser radiation, depending on the parameters used, affects fluidity and stability of liposomes with the lipid content similar to erythrocyte membrane, it may also cause structural and functional changes in cell membranes.

  18. The effect of near-infrared MLS laser radiation on cell membrane structure and radical generation.

    Science.gov (United States)

    Kujawa, Jolanta; Pasternak, Kamila; Zavodnik, Ilya; Irzmański, Robert; Wróbel, Dominika; Bryszewska, Maria

    2014-09-01

    The therapeutic effects of low-power laser radiation of different wavelengths and light doses are well known, but the biochemical mechanism of the interaction of laser light with living cells is not fully understood. We have investigated the effect of MLS (Multiwave Locked System) laser near-infrared irradiation on cell membrane structure, functional properties, and free radical generation using human red blood cells and breast cancer MCF-4 cells. The cells were irradiated with low-intensity MLS near-infrared (simultaneously 808 nm, continuous emission and 905 nm, pulse emission, pulse-wave frequency, 1,000 or 2,000 Hz) laser light at light doses from 0 to 15 J (average power density 212.5 mW/cm(2), spot size was 3.18 cm(2)) at 22 °C, the activity membrane bound acetylcholinesterase, cell stability, anti-oxidative activity, and free radical generation were the parameters used in characterizing the structural and functional changes of the cell. Near-infrared low-intensity laser radiation changed the acetylcholinesterase activity of the red blood cell membrane in a dose-dependent manner: There was a considerable increase of maximal enzymatic rate and Michaelis constant due to changes in the membrane structure. Integral parameters such as erythrocyte stability, membrane lipid peroxidation, or methemoglobin levels remained unchanged. Anti-oxidative capacity of the red blood cells increased after MLS laser irradiation. This irradiation induced a time-dependent increase in free radical generation in MCF-4 cells. Low-intensity near-infrared MLS laser radiation induces free radical generation and changes enzymatic and anti-oxidative activities of cellular components. Free radical generation may be the mechanism of the biomodulative effect of laser radiation.

  19. Preparation of hypoxic imaging agents 99Tcm-MNLS and 99Tcm-MLS and their biodistribution in mice

    International Nuclear Information System (INIS)

    Zha Zhihao; Wang Jianjun; Zhu Lin

    2009-01-01

    To develop 99 Tc m labeled hypoxic agents,two phosphate-based chelating agents were coupled to metronidazole, 2- (2-methyl-5-nitro-1H-imidazol-1-yl) ethyl dihydrogen phosphate (MNLS) and its analog 2- (2-methyl-1H-imidazol-1-yl) ethyl dihydrogen phosphate (MLS) were synthesized based on the mechanism of prodrug. Labeling yield of these 99 Tc m complexes were more than 90% as proved by TLC. Paper electrophoresis showed that these complexes were neutral. Biodistribution of these complexes in tumor-bearing mice showed that the uptake of 99 Tc m -MNLS (120 min, 2.99 ± 0.25 ID%/g) in tumor was higher than that of 99 Tc m -HL91 (120 min, 0.93 ± 0.13 ID%/g) and 99 Tc m -MLS (120 min, 1.61 ± 0.13 ID%/g), and the uptake ratio of tumor to muscle and tumor to liver of 99 Tc m -MNLS (120 min, 5.90, 1.03) were higher than that of 99 Tc m -HL91 (120 min, 3.59, 0.17) and 99 Tc m -MLS (120 min, 5.40, 0.13). The higher tumor uptake for 99 Tc m -MNLS than 99 Tc m -MLS suggested that nitroimidazole was a key group for tumor accumulation. 99 Tc m -MNLS had higher tumor uptake and lower liver uptake, which had the potential for tumor imaging and was worth of further vestigation. (authors)

  20. MLS (Microwave Landing System) Multipath Studies, Phase 3. Volume 3. Application of Models to MLS Assessment Issues. Part 1. Chapters 1 through 4.

    Science.gov (United States)

    1981-06-08

    generated by the AWOP panel members from the FRG, Netherlands, U.K., and U.S. 1-3 Airport-specific simulations, intended to predict MLS performance at a...05. C.𔃼 C. 00 0,5 r, !,. . lSTM FIN I l "i Fig. 2-89. Elevation rate error filter output for scenario 4. 2-116...Report No. 1, Texas Instruments Incorporated, Dallas, Texas (25 June 1975), ALEX(03)-TR-75-01. 50. J. Makhoul, "Linear Prediction ; A Tutorial Review

  1. 76 FR 24045 - Notice of HUD-Held Multifamily Loan Sale (MLS 2011-1)

    Science.gov (United States)

    2011-04-29

    ..., the bidder's deposit was non-refundable and was applied toward the purchase price. Deposits were... Commissioner, HUD. ACTION: Notice of sale of mortgage loans. SUMMARY: This notice announces HUD's intention to... INFORMATION: HUD announces its intention to sell in MLS 2011-1 certain unsubsidized mortgage loans (Mortgage...

  2. Polar stratospheric cloud evolution and chlorine activation measured by CALIPSO and MLS, and modeled by ATLAS

    Directory of Open Access Journals (Sweden)

    H. Nakajima

    2016-03-01

    Full Text Available We examined observations of polar stratospheric clouds (PSCs by CALIPSO, and of HCl and ClO by MLS along air mass trajectories, to investigate the dependence of the inferred PSC composition on the temperature history of the air parcels and the dependence of the level of chlorine activation on PSC composition. Several case studies based on individual trajectories from the Arctic winter 2009/2010 were conducted, with the trajectories chosen such that the first processing of the air mass by PSCs in this winter occurred on the trajectory. Transitions of PSC composition classes were observed to be highly dependent on the temperature history. In cases of a gradual temperature decrease, nitric acid trihydrate (NAT and super-cooled ternary solution (STS mixture clouds were observed. In cases of rapid temperature decrease, STS clouds were first observed, followed by NAT/STS mixture clouds. When temperatures dropped below the frost point, ice clouds formed and then transformed into NAT/STS mixture clouds when temperature increased above the frost point. The threshold temperature for rapid chlorine activation on PSCs is approximately 4 K below the NAT existence temperature, TNAT. Furthermore, simulations of the ATLAS chemistry and transport box model along the trajectories were used to corroborate the measurements and show good agreement with the observations. Rapid chlorine activation was observed when an air mass encountered PSCs. Usually, chlorine activation was limited by the amount of available ClONO2. Where ClONO2 was not the limiting factor, a large dependence on temperature was evident.

  3. MIPAS temperature from the stratosphere to the lower thermosphere: Comparison of vM21 with ACE-FTS, MLS, OSIRIS, SABER, SOFIE and lidar measurements

    Directory of Open Access Journals (Sweden)

    M. García-Comas

    2014-11-01

    Full Text Available We present vM21 MIPAS temperatures from the lower stratosphere to the lower thermosphere, which cover all optimized resolution measurements performed by MIPAS in the middle-atmosphere, upper-atmosphere and noctilucent-cloud modes during its lifetime, i.e., from January 2005 to April 2012. The main upgrades with respect to the previous version of MIPAS temperatures (vM11 are the update of the spectroscopic database, the use of a different climatology of atomic oxygen and carbon dioxide, and the improvement in important technical aspects of the retrieval setup (temperature gradient along the line of sight and offset regularizations, apodization accuracy. Additionally, an updated version of ESA-calibrated L1b spectra (5.02/5.06 is used. The vM21 temperatures correct the main systematic errors of the previous version because they provide on average a 1–2 K warmer stratopause and middle mesosphere, and a 6–10 K colder mesopause (except in high-latitude summers and lower thermosphere. These lead to a remarkable improvement in MIPAS comparisons with ACE-FTS, MLS, OSIRIS, SABER, SOFIE and the two Rayleigh lidars at Mauna Loa and Table Mountain, which, with a few specific exceptions, typically exhibit differences smaller than 1 K below 50 km and than 2 K at 50–80 km in spring, autumn and winter at all latitudes, and summer at low to midlatitudes. Differences in the high-latitude summers are typically smaller than 1 K below 50 km, smaller than 2 K at 50–65 km and 5 K at 65–80 km. Differences between MIPAS and the other instruments in the mid-mesosphere are generally negative. MIPAS mesopause is within 4 K of the other instruments measurements, except in the high-latitude summers, when it is within 5–10 K, being warmer there than SABER, MLS and OSIRIS and colder than ACE-FTS and SOFIE. The agreement in the lower thermosphere is typically better than 5 K, except for high latitudes during spring and summer, when MIPAS usually exhibits larger

  4. EOS MLS Level 2 Data Processing Software Version 3

    Science.gov (United States)

    Livesey, Nathaniel J.; VanSnyder, Livesey W.; Read, William G.; Schwartz, Michael J.; Lambert, Alyn; Santee, Michelle L.; Nguyen, Honghanh T.; Froidevaux, Lucien; wang, Shuhui; Manney, Gloria L.; hide

    2011-01-01

    This software accepts the EOS MLS calibrated measurements of microwave radiances products and operational meteorological data, and produces a set of estimates of atmospheric temperature and composition. This version has been designed to be as flexible as possible. The software is controlled by a Level 2 Configuration File that controls all aspects of the software: defining the contents of state and measurement vectors, defining the configurations of the various forward models available, reading appropriate a priori spectroscopic and calibration data, performing retrievals, post-processing results, computing diagnostics, and outputting results in appropriate files. In production mode, the software operates in a parallel form, with one instance of the program acting as a master, coordinating the work of multiple slave instances on a cluster of computers, each computing the results for individual chunks of data. In addition, to do conventional retrieval calculations and producing geophysical products, the Level 2 Configuration File can instruct the software to produce files of simulated radiances based on a state vector formed from a set of geophysical product files taken as input. Combining both the retrieval and simulation tasks in a single piece of software makes it far easier to ensure that identical forward model algorithms and parameters are used in both tasks. This also dramatically reduces the complexity of the code maintenance effort.

  5. Keeping Pace with Information Literacy Instruction for the Real World: When Will MLS Programs Wake Up and Smell the LILACs?

    Directory of Open Access Journals (Sweden)

    Kimberly Davies-Hoffman

    2013-08-01

    Full Text Available For over thirty years, numerous studies have discussed the contradiction between the growing importance of information literacy instruction to the Library’s core mission and lack of pedagogical training for new librarians. This article reviews the more recent contributions on the topic, presents a survey of New York State MLS curricula and describes initiatives of pedagogy training offered in that region outside of MLS programs. The authors focus on the Library Instruction Leadership Academy (LILAC, an innovative, semester-long training program created in Western New York State to offer instruction in the pedagogical foundation and practical experience essential for teaching information literacy skills effectively. They provide details of the program’s content, organization, funding, assessment methods, and learning outcomes. While regional initiatives like LILAC prove to be very valuable to their participants, the authors aim to apply pressure on MLS programs to establish curricular requirements better suited to the demands of today's librarianship.

  6. Morphological Operations to Extract Urban Curbs in 3D MLS Point Clouds

    Directory of Open Access Journals (Sweden)

    Borja Rodríguez-Cuenca

    2016-06-01

    Full Text Available Automatic curb detection is an important issue in road maintenance, three-dimensional (3D urban modeling, and autonomous navigation fields. This paper is focused on the segmentation of curbs and street boundaries using a 3D point cloud captured by a mobile laser scanner (MLS system. Our method provides a solution based on the projection of the measured point cloud on the XY plane. Over that plane, a segmentation algorithm is carried out based on morphological operations to determine the location of street boundaries. In addition, a solution to extract curb edges based on the roughness of the point cloud is proposed. The proposed method is valid in both straight and curved road sections and applicable both to laser scanner and stereo vision 3D data due to the independence of its scanning geometry. The proposed method has been successfully tested with two datasets measured by different sensors. The first dataset corresponds to a point cloud measured by a TOPCON sensor in the Spanish town of Cudillero. The second dataset corresponds to a point cloud measured by a RIEGL sensor in the Austrian town of Horn. The extraction method provides completeness and correctness rates above 90% and quality values higher than 85% in both studied datasets.

  7. Soft-sensing Modeling Based on MLS-SVM Inversion for L-lysine Fermentation Processes

    Directory of Open Access Journals (Sweden)

    Bo Wang

    2015-06-01

    Full Text Available A modeling approach 63 based on multiple output variables least squares support vector machine (MLS-SVM inversion is presented by a combination of inverse system and support vector machine theory. Firstly, a dynamic system model is developed based on material balance relation of a fed-batch fermentation process, with which it is analyzed whether an inverse system exists or not, and into which characteristic information of a fermentation process is introduced to set up an extended inversion model. Secondly, an initial extended inversion model is developed off-line by the use of the fitting capacity of MLS-SVM; on-line correction is made by the use of a differential evolution (DE algorithm on the basis of deviation information. Finally, a combined pseudo-linear system is formed by means of a serial connection of a corrected extended inversion model behind the L-lysine fermentation processes; thereby crucial biochemical parameters of a fermentation process could be predicted on-line. The simulation experiment shows that this soft-sensing modeling method features very high prediction precision and can predict crucial biochemical parameters of L-lysine fermentation process very well.

  8. Impact of Time Lapse on ASCP Board of Certification Medical Laboratory Scientist (MLS) and Medical Laboratory Technician (MLT) Examination Scores.

    Science.gov (United States)

    Brown, Karen A; Fenn, JoAnn P; Freeman, Vicki S; Fisher, Patrick B; Genzen, Jonathan R; Goodyear, Nancy; Houston, Mary Lunz; O'Brien, Mary Elizabeth; Tanabe, Patricia A

    2015-01-01

    Research in several professional fields has demonstrated that delays (time lapse) in taking certification examinations may result in poorer performance by examinees. Thirteen states and/or territories require licensure for laboratory personnel. A core component of licensure is passing a certification exam. Also, many facilities in states that do not require licensure require certification for employment or preferentially hire certified individuals. To analyze examinee performance on the American Society for Clinical Pathology (ASCP) Board of Certification (BOC) Medical Laboratory Scientist (MLS) and Medical Laboratory Technician (MLT) certification examinations to determine whether delays in taking the examination from the time of program completion are associated with poorer performance. We obtained examination data from April 2013 through December 2014 to look for changes in mean (SD) exam scaled scores and overall pass/fail rates. First-time examinees (MLS: n = 6037; MLT, n = 3920) were divided into 3-month categories based on the interval of time between date of program completion and taking the certification exam. We observed significant decreases in mean (SD) scaled scores and pass rates after the first quarter in MLS and MLT examinations for applicants who delayed taking their examination until the second, third, and fourth quarter after completing their training programs. Those who take the ASCP BOC MLS and MLT examinations are encouraged to do so shortly after completion of their educational training programs. Delays in taking an exam are generally not beneficial to the examinee and result in poorer performance on the exam. Copyright© by the American Society for Clinical Pathology (ASCP).

  9. Distinct fates of self-specific T cells developing in irradiation bone marrow chimeras: Clonal deletion, clonal anergy, or in vitro responsiveness to self-Mls-1a controlled by hemopoietic cells in the thymus

    International Nuclear Information System (INIS)

    Speiser, D.E.; Chvatchko, Y.; Zinkernagel, R.M.; MacDonald, H.R.

    1990-01-01

    Elimination of potentially self-reactive T lymphocytes during their maturation in the thymus has been shown to be a major mechanism in accomplishing self-tolerance. Previous reports demonstrated that clonal deletion of self-Mls-1a-specific V beta 6+ T lymphocyte is controlled by a radiosensitive I-E+ thymic component. Irradiation chimeras reconstituted with I-E- bone marrow showed substantial numbers of mature V beta 6+ T cells despite host Mls-1a expression. Analysis of the functional properties of such chimeric T cells revealed a surprising variability in their in vitro reactivity to host Mls-1a, depending on the H-2 haplotype of stem cells used for reconstitution. In chimeras reconstituted with B10.S (H-2s) stem cells, mature V beta 6+ lymphocytes were present but functionally anergic to host-type Mls-1a in vitro. In contrast, in chimeras reconstituted with B10.G (H-2q) bone marrow, nondeleted V beta 6+ cells were highly responsive to Mls-1a in vitro. These findings suggest that clonal anergy of V beta 6+ cells to self-Mls-1a may be controlled by the affinity/avidity of T cell receptor interactions with bone marrow-derived cells in the thymus depending on the major histocompatibility complex class II molecules involved. Furthermore, chimeras bearing host (Mls-1a)-reactive V beta 6+ cells did not differ clinically from those with anergic or deleted V beta 6+ cells and survived more than one year without signs of autoimmune disease. Interestingly, their spleen cells had no Mls-1a stimulatory capacity in vitro. Therefore, regulation at the level of antigen presentation may be an alternative mechanism for maintenance of tolerance to certain self-antigens such as Mls-1a

  10. Long-term Global Morphology of Gravity Wave Activity Using UARS Data

    Science.gov (United States)

    Eckermann, Stephen D.; Jackman, C. (Technical Monitor)

    2000-01-01

    This quarter was largely devoted to a detailed study of temperature data acquired by the Cryogenic Limb Array Etalon Spectrometer (CLAES) on UARS. Our analysis used the same sequence of methods that have been developed, tested and refined on a more limited subset of temperature data acquired by the CRISTA instrument. We focused on a limited subset of our reasoning that geographical and vertical trends in the small-scale temperature variability could be compared with similar trends observed in November 1994 by the CRISTA-SPAS satellite. Results, backed up with hindcasts from the Mountain Wave Forecast Model (MWFM), reveal strong evidence of mountain waves, most persuasively in the Himalayas on 16-17 November, 1992. These CLAES results are coherent over the 30-50 km range and compare well with MWFM hindcasts for the same period. This constitutes, we believe, the first clear evidence that CLAES explicitly resolved long wavelength gravity waves in its CO2 temperature channel. A series of other tasks, related to mesoscale modeling of mountain waves in CRISTA data and fitting of ground-based and HRDI data on global scales, were seen through to publication stage in peer-reviewed journals.

  11. MLS/Aura Near-Real-Time L2 Nitrous Oxide (N2O) Mixing Ratio V003

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2N2O_NRT is the EOS Aura Microwave Limb Sounder (MLS) Near-Real-Time (NRT) product for nitrous oxide (N2O). This product contains daily N2O profiles taken from the...

  12. Relative drifts and stability of satellite and ground-based stratospheric ozone profiles at NDACC lidar stations

    Directory of Open Access Journals (Sweden)

    P. J. Nair

    2012-06-01

    Full Text Available The long-term evolution of stratospheric ozone at different stations in the low and mid-latitudes is investigated. The analysis is performed by comparing the collocated profiles of ozone lidars, at the northern mid-latitudes (Meteorological Observatory Hohenpeißenberg, Haute-Provence Observatory, Tsukuba and Table Mountain Facility, tropics (Mauna Loa Observatory and southern mid-latitudes (Lauder, with ozonesondes and space-borne sensors (SBUV(/2, SAGE II, HALOE, UARS MLS and Aura MLS, extracted around the stations. Relative differences are calculated to find biases and temporal drifts in the measurements. All measurement techniques show their best agreement with respect to the lidar at 20–40 km, where the differences and drifts are generally within ±5% and ±0.5% yr−1, respectively, at most stations. In addition, the stability of the long-term ozone observations (lidar, SBUV(/2, SAGE II and HALOE is evaluated by the cross-comparison of each data set. In general, all lidars and SBUV(/2 exhibit near-zero drifts and the comparison between SAGE II and HALOE shows larger, but insignificant drifts. The RMS of the drifts of lidar and SBUV(/2 is 0.22 and 0.27% yr−1, respectively at 20–40 km. The average drifts of the long-term data sets, derived from various comparisons, are less than ±0.3% yr−1 in the 20–40 km altitude at all stations. A combined time series of the relative differences between SAGE II, HALOE and Aura MLS with respect to lidar data at six sites is constructed, to obtain long-term data sets lasting up to 27 years. The relative drifts derived from these combined data are very small, within ±0.2% yr−1.

  13. Validation of Aura Microwave Limb Sounder stratospheric water vapor measurements by the NOAA frost point hygrometer.

    Science.gov (United States)

    Hurst, Dale F; Lambert, Alyn; Read, William G; Davis, Sean M; Rosenlof, Karen H; Hall, Emrys G; Jordan, Allen F; Oltmans, Samuel J

    2014-02-16

    Differences between stratospheric water vapor measurements by NOAA frost point hygrometers (FPHs) and the Aura Microwave Limb Sounder (MLS) are evaluated for the period August 2004 through December 2012 at Boulder, Colorado, Hilo, Hawaii, and Lauder, New Zealand. Two groups of MLS profiles coincident with the FPH soundings at each site are identified using unique sets of spatiotemporal criteria. Before evaluating the differences between coincident FPH and MLS profiles, each FPH profile is convolved with the MLS averaging kernels for eight pressure levels from 100 to 26 hPa (~16 to 25 km) to reduce its vertical resolution to that of the MLS water vapor retrievals. The mean FPH - MLS differences at every pressure level (100 to 26 hPa) are well within the combined measurement uncertainties of the two instruments. However, the mean differences at 100 and 83 hPa are statistically significant and negative, ranging from -0.46 ± 0.22 ppmv (-10.3 ± 4.8%) to -0.10 ± 0.05 ppmv (-2.2 ± 1.2%). Mean differences at the six pressure levels from 68 to 26 hPa are on average 0.8% (0.04 ppmv), and only a few are statistically significant. The FPH - MLS differences at each site are examined for temporal trends using weighted linear regression analyses. The vast majority of trends determined here are not statistically significant, and most are smaller than the minimum trends detectable in this analysis. Except at 100 and 83 hPa, the average agreement between MLS retrievals and FPH measurements of stratospheric water vapor is better than 1%.

  14. SYNERGISTIC EFFECTS OF ETHANOL MEDICINAL PLANT EXTRACTS WITH ERYTHROMYCIN AGAINST SKIN STRAINS OF STAPHYLOCOCCI WITH INDUCIBLE PHENOTYPE OF MLS-RESISTANCE

    Directory of Open Access Journals (Sweden)

    Yurchyshyn O.I.

    2017-10-01

    Full Text Available Introduction. One of the main ways to control microorganisms’ resistance to antibiotics is to find substances that are able to overcome it and potentiate antibiotics action, in particular to neutralize the antibiotic-inactivating enzymes or block the active efflux of antibiotic from microbial cells. Every year there is a growing interest in the therapeutic potential of herbal active compounds as modifiers of antibiotic resistance including MLS-resistance (macrolide-lincosamide-streptoramin B. It should be emphasized that a number of biologically active substances of plant origin can potentiate antimicrobial activity of erythromycin (ERY against MLS-resistant staphylococci. The present study was designed to investigate the antibacterial and synergistic effects of eight Ukrainian ethanol medicinal plant extracts with erythromycin against skin strains of staphylococci with inducible phenotype of MLS-resistance. Material & methods. S. aureus and S. epidermidis strains were tested for susceptibility to antibiotics of MLS-group by disk diffusion test. Effective antimicrobial concentrations of plant extracts and erythromycin were determined by two-fold serial dilution in nutrient agar and broth. Combinatory effects between organic extracts and ERY were assessed using the checkerboard assay against tested strains to evaluate culture growth in the presence of two antimicrobials with different concentrations. Results & discussion. The Alnus incana L. fruits extract was the most potent inhibitor against tested strains (MIC 40.625-162.5 µg/mL; while Geranium pratense L. rhizomes extract exhibited the least antimicrobial activity (MIC 650-2,600 µg/mL. The Alnus incana L. fruits extract and the Geranium pratense L. rhizomes extract showed synergistic effect with erythromycin against 100% strains of staphylococci (average FICI 0.028 – 0.057; p<0.001. In the presence of 1/4 MIC of ERY Alnus incana L. fruits extract antimicrobial concentration was

  15. Development of an unmanned agricultural robotics system for measuring crop conditions for precision aerial application

    Science.gov (United States)

    An Unmanned Agricultural Robotics System (UARS) is acquired, rebuilt with desired hardware, and operated in both classrooms and field. The UARS includes crop height sensor, crop canopy analyzer, normalized difference vegetative index (NDVI) sensor, multispectral camera, and hyperspectral radiometer...

  16. Navigation and flight director guidance for the NASA/FAA helicopter MLS curved approach flight test program

    Science.gov (United States)

    Phatak, A. V.; Lee, M. G.

    1985-01-01

    The navigation and flight director guidance systems implemented in the NASA/FAA helicopter microwave landing system (MLS) curved approach flight test program is described. Flight test were conducted at the U.S. Navy's Crows Landing facility, using the NASA Ames UH-lH helicopter equipped with the V/STOLAND avionics system. The purpose of these tests was to investigate the feasibility of flying complex, curved and descending approaches to a landing using MLS flight director guidance. A description of the navigation aids used, the avionics system, cockpit instrumentation and on-board navigation equipment used for the flight test is provided. Three generic reference flight paths were developed and flown during the test. They were as follows: U-Turn, S-turn and Straight-In flight profiles. These profiles and their geometries are described in detail. A 3-cue flight director was implemented on the helicopter. A description of the formulation and implementation of the flight director laws is also presented. Performance data and analysis is presented for one pilot conducting the flight director approaches.

  17. Role of Stratospheric Water Vapor in Global Warming from GCM Simulations Constrained by MLS Observation

    Science.gov (United States)

    Wang, Y.; Stek, P. C.; Su, H.; Jiang, J. H.; Livesey, N. J.; Santee, M. L.

    2014-12-01

    Over the past century, global average surface temperature has warmed by about 0.16°C/decade, largely due to anthropogenic increases in well-mixed greenhouse gases. However, the trend in global surface temperatures has been nearly flat since 2000, raising a question regarding the exploration of the drivers of climate change. Water vapor is a strong greenhouse gas in the atmosphere. Previous studies suggested that the sudden decrease of stratospheric water vapor (SWV) around 2000 may have contributed to the stall of global warming. Since 2004, the SWV observed by Microwave Limb Sounder (MLS) on Aura satellite has shown a slow recovery. The role of recent SWV variations in global warming has not been quantified. We employ a coupled atmosphere-ocean climate model, the NCAR CESM, to address this issue. It is found that the CESM underestimates the stratospheric water vapor by about 1 ppmv due to limited representations of the stratospheric dynamic and chemical processes important for water vapor variabilities. By nudging the modeled SWV to the MLS observation, we find that increasing SWV by 1 ppmv produces a robust surface warming about 0.2°C in global-mean when the model reaches equilibrium. Conversely, the sudden drop of SWV from 2000 to 2004 would cause a surface cooling about -0.08°C in global-mean. On the other hand, imposing the observed linear trend of SWV based on the 10-year observation of MLS in the CESM yields a rather slow surface warming, about 0.04°C/decade. Our model experiments suggest that SWV contributes positively to the global surface temperature variation, although it may not be the dominant factor that drives the recent global warming hiatus. Additional sensitivity experiments show that the impact of SWV on surface climate is mostly governed by the SWV amount at 100 hPa in the tropics. Furthermore, the atmospheric model simulations driven by observed sea surface temperature (SST) show that the inter-annual variation of SWV follows that of SST

  18. SEMANTIC LABELLING OF ULTRA DENSE MLS POINT CLOUDS IN URBAN ROAD CORRIDORS BASED ON FUSING CRF WITH SHAPE PRIORS

    Directory of Open Access Journals (Sweden)

    W. Yao

    2017-09-01

    Full Text Available In this paper, a labelling method for the semantic analysis of ultra-high point density MLS data (up to 4000 points/m2 in urban road corridors is developed based on combining a conditional random field (CRF for the context-based classification of 3D point clouds with shape priors. The CRF uses a Random Forest (RF for generating the unary potentials of nodes and a variant of the contrastsensitive Potts model for the pair-wise potentials of node edges. The foundations of the classification are various geometric features derived by means of co-variance matrices and local accumulation map of spatial coordinates based on local neighbourhoods. Meanwhile, in order to cope with the ultra-high point density, a plane-based region growing method combined with a rule-based classifier is applied to first fix semantic labels for man-made objects. Once such kind of points that usually account for majority of entire data amount are pre-labeled; the CRF classifier can be solved by optimizing the discriminative probability for nodes within a subgraph structure excluded from pre-labeled nodes. The process can be viewed as an evidence fusion step inferring a degree of belief for point labelling from different sources. The MLS data used for this study were acquired by vehicle-borne Z+F phase-based laser scanner measurement, which permits the generation of a point cloud with an ultra-high sampling rate and accuracy. The test sites are parts of Munich City which is assumed to consist of seven object classes including impervious surfaces, tree, building roof/facade, low vegetation, vehicle and pole. The competitive classification performance can be explained by the diverse factors: e.g. the above ground height highlights the vertical dimension of houses, trees even cars, but also attributed to decision-level fusion of graph-based contextual classification approach with shape priors. The use of context-based classification methods mainly contributed to smoothing of

  19. Semantic Labelling of Ultra Dense Mls Point Clouds in Urban Road Corridors Based on Fusing Crf with Shape Priors

    Science.gov (United States)

    Yao, W.; Polewski, P.; Krzystek, P.

    2017-09-01

    In this paper, a labelling method for the semantic analysis of ultra-high point density MLS data (up to 4000 points/m2) in urban road corridors is developed based on combining a conditional random field (CRF) for the context-based classification of 3D point clouds with shape priors. The CRF uses a Random Forest (RF) for generating the unary potentials of nodes and a variant of the contrastsensitive Potts model for the pair-wise potentials of node edges. The foundations of the classification are various geometric features derived by means of co-variance matrices and local accumulation map of spatial coordinates based on local neighbourhoods. Meanwhile, in order to cope with the ultra-high point density, a plane-based region growing method combined with a rule-based classifier is applied to first fix semantic labels for man-made objects. Once such kind of points that usually account for majority of entire data amount are pre-labeled; the CRF classifier can be solved by optimizing the discriminative probability for nodes within a subgraph structure excluded from pre-labeled nodes. The process can be viewed as an evidence fusion step inferring a degree of belief for point labelling from different sources. The MLS data used for this study were acquired by vehicle-borne Z+F phase-based laser scanner measurement, which permits the generation of a point cloud with an ultra-high sampling rate and accuracy. The test sites are parts of Munich City which is assumed to consist of seven object classes including impervious surfaces, tree, building roof/facade, low vegetation, vehicle and pole. The competitive classification performance can be explained by the diverse factors: e.g. the above ground height highlights the vertical dimension of houses, trees even cars, but also attributed to decision-level fusion of graph-based contextual classification approach with shape priors. The use of context-based classification methods mainly contributed to smoothing of labelling by removing

  20. Interrelated variations of O3, CO and deep convection in the tropical/subtropical upper troposphere observed by the Aura Microwave Limb Sounder (MLS during 2004–2011

    Directory of Open Access Journals (Sweden)

    L. Froidevaux

    2013-01-01

    Full Text Available The interrelated geographic and temporal variability seen in more than seven years of tropical and subtropical upper tropospheric (215 hPa ozone, carbon monoxide and cloud ice water content (IWC observations by the Aura Microwave Limb Sounder (MLS are presented. Observed ozone abundances and their variability (geographic and temporal agree to within 10–15 ppbv with records from sonde observations. MLS complements these (and other observations with global coverage and simultaneous measurements of related parameters. Previously-reported phenomena such as the ozone "wave one" feature are clearly seen in the MLS observations, as is a double peak in ozone abundance over tropical East Africa, with enhanced abundances in both May to June and September to November. While repeatable seasonal cycles are seen in many regions, they are often accompanied by significant interannual variability. Ozone seasonal cycles in the southern tropics and subtropics tend to be more distinct (i.e., annually repeatable than in the northern. By contrast, carbon monoxide shows distinct seasonal cycles in many northern subtropical regions, notably from India to the Eastern Pacific. Deep convection (as indicated by large values of IWC is typically associated with reductions in upper tropospheric ozone. Convection over polluted regions is seen to significantly enhance upper tropospheric carbon monoxide. While some regions show statistically significant correlations among ozone, carbon monoxide and IWC, simple correlations fall well short of accounting for the observed variability. The observed interrelated variations and metrics of annual and interannual variability described here represent a new resource for validation of atmospheric chemistry models.

  1. Recent divergences in stratospheric water vapor measurements by frost point hygrometers and the Aura Microwave Limb Sounder.

    Science.gov (United States)

    Hurst, Dale F; Read, William G; Vömel, Holger; Selkirk, Henry B; Rosenlof, Karen H; Davis, Sean M; Hall, Emrys G; Jordan, Allen F; Oltmans, Samuel J

    2016-09-08

    Balloon-borne frost point hygrometers (FPs) and the Aura Microwave Limb Sounder (MLS) provide high-quality vertical profile measurements of water vapor in the upper troposphere and lower stratosphere (UTLS). A previous comparison of stratospheric water vapor measurements by FPs and MLS over three sites - Boulder, Colorado (40.0° N); Hilo, Hawaii (19.7° N); and Lauder, New Zealand (45.0° S) - from August 2004 through December 2012 not only demonstrated agreement better than 1% between 68 and 26 hPa but also exposed statistically significant biases of 2 to 10% at 83 and 100 hPa (Hurst et al., 2014). A simple linear regression analysis of the FP-MLS differences revealed no significant long-term drifts between the two instruments. Here we extend the drift comparison to mid-2015 and add two FP sites - Lindenberg, Germany (52.2° N), and San José, Costa Rica (10.0° N) - that employ FPs of different manufacture and calibration for their water vapor soundings. The extended comparison period reveals that stratospheric FP and MLS measurements over four of the five sites have diverged at rates of 0.03 to 0.07 ppmv year -1 (0.6 to 1.5% year -1 ) from ~2010 to mid-2015. These rates are similar in magnitude to the 30-year (1980-2010) average growth rate of stratospheric water vapor (~ 1% year -1 ) measured by FPs over Boulder (Hurst et al., 2011). By mid-2015, the FP-MLS differences at some sites were large enough to exceed the combined accuracy estimates of the FP and MLS measurements.

  2. MLS-Net and SecureParser®: A New Method for Securing and Segregating Network Data

    Directory of Open Access Journals (Sweden)

    Robert A. Johnson

    2008-10-01

    Full Text Available A new method of network security and virtualization is presented which allows the consolidation of multiple network infrastructures dedicated to single security levels or communities of interest onto a single, virtualized network. An overview of the state of the art of network security protocols is presented, including the use of SSL, IPSec, and HAIPE IS, followed by a discussion of the SecureParser® technology and MLS-Net architecture, which in combination allow the virtualization of local network enclaves.

  3. A-train CALIOP and MLS observations of early winter Antarctic polar stratospheric clouds and nitric acid in 2008

    Directory of Open Access Journals (Sweden)

    A. Lambert

    2012-03-01

    Full Text Available A-train Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP and Microwave Limb Sounder (MLS observations are used to investigate the development of polar stratospheric clouds (PSCs and the gas-phase nitric acid distribution in the early 2008 Antarctic winter. Observational evidence of gravity-wave activity is provided by Atmospheric Infrared Sounder (AIRS radiances and infrared spectroscopic detection of nitric acid trihydrate (NAT in PSCs is obtained from the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS. Goddard Earth Observing System Data Assimilation System (GEOS-5 DAS analyses are used to derive Lagrangian trajectories and to determine temperature-time histories of air parcels. We use CALIOP backscatter and depolarization measurements to classify PSCs and the MLS measurements to determine the corresponding gas-phase HNO3 as a function of temperature. For liquid PSCs the uptake of HNO3 follows the theoretical equilibrium curve for supercooled ternary solutions (STS, but at temperatures about 1 K lower as determined from GEOS-5. In the presence of solid phase PSCs, above the ice frost-point, the HNO3 depletion occurs over a wider range of temperatures (+2 to −7 K distributed about the NAT equilibrium curve. Rapid gas-phase HNO3 depletion is first seen by MLS from from 23–25 May 2008, consisting of a decrease in the volume mixing ratio from 14 ppbv (parts per billion by volume to 7 ppbv on the 46–32 hPa (hectopascal pressure levels and accompanied by a 2–3 ppbv increase by renitrification at the 68 hPa pressure level. The observed region of depleted HNO3 is substantially smaller than the region bounded by the NAT existence temperature threshold. Temperature-time histories of air parcels demonstrate that the depletion is more clearly correlated with prior exposure to temperatures a few kelvin above the frost-point. From the combined data we infer the presence

  4. Accuracy and precision of polar lower stratospheric temperatures from reanalyses evaluated from A-Train CALIOP and MLS, COSMIC GPS RO, and the equilibrium thermodynamics of supercooled ternary solutions and ice clouds

    Science.gov (United States)

    Lambert, Alyn; Santee, Michelle L.

    2018-02-01

    We investigate the accuracy and precision of polar lower stratospheric temperatures (100-10 hPa during 2008-2013) reported in several contemporary reanalysis datasets comprising two versions of the Modern-Era Retrospective analysis for Research and Applications (MERRA and MERRA-2), the Japanese 55-year Reanalysis (JRA-55), the European Centre for Medium-Range Weather Forecasts (ECMWF) interim reanalysis (ERA-I), and the National Oceanic and Atmospheric Administration (NOAA) National Centers for Environmental Prediction (NCEP) Climate Forecast System Reanalysis (NCEP-CFSR). We also include the Goddard Earth Observing System model version 5.9.1 near-real-time analysis (GEOS-5.9.1). Comparisons of these datasets are made with respect to retrieved temperatures from the Aura Microwave Limb Sounder (MLS), Constellation Observing System for Meteorology, Ionosphere and Climate (COSMIC) Global Positioning System (GPS) radio occultation (RO) temperatures, and independent absolute temperature references defined by the equilibrium thermodynamics of supercooled ternary solutions (STSs) and ice clouds. Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) observations of polar stratospheric clouds are used to determine the cloud particle types within the Aura MLS geometric field of view. The thermodynamic calculations for STS and the ice frost point use the colocated MLS gas-phase measurements of HNO3 and H2O. The estimated bias and precision for the STS temperature reference, over the 68 to 21 hPa pressure range, are 0.6-1.5 and 0.3-0.6 K, respectively; for the ice temperature reference, they are 0.4 and 0.3 K, respectively. These uncertainties are smaller than those estimated for the retrieved MLS temperatures and also comparable to GPS RO uncertainties (bias 0.7 K) in the same pressure range. We examine a case study of the time-varying temperature structure associated with layered ice clouds formed by orographic gravity waves forced by flow over the Palmer Peninsula and

  5. Global distributions of diurnal and semi-diurnal tides: observations from HRDI-UARS of the MLT region

    Directory of Open Access Journals (Sweden)

    A. H. Manson

    2002-11-01

    Full Text Available HRDI (High Resolution Doppler Interferometer-UARS winds data have been analyzed in 4° latitude by 10° longitude cells at 96 km to obtain global contour maps of solar-tidal amplitudes and phases, and also mean winds. The solstices June–July (1993, December–January (1993–1994, and one equinox September–October (1994 are shown.  The 24-h diurnal tide that maximizes near the 20–25° latitude has significant seasonal changes with equinoctial maxima, and very clear longitudinal variability. Maxima are very clear over the oceans. In contrast, the 12-h semi-diurnal tides that maximize near the 40–55° latitude have very strong seasonal changes with winter maxima, and more modest longitudinal changes. The similarities with MLT (mesosphere-lower thermosphere radar observations (90 km and the GSWM (Global Scale Wave Model are very satisfactory. The mean winds are consistent with expectations and show clear poleward flow from summer to winter hemispheres in the solstices.Key words. Meteorology and atmospheric dynamics (middle atmosphere dynamics; waves and tides Radio science (remote sensing

  6. Global distributions of diurnal and semi-diurnal tides: observations from HRDI-UARS of the MLT region

    Directory of Open Access Journals (Sweden)

    A. H. Manson

    Full Text Available HRDI (High Resolution Doppler Interferometer-UARS winds data have been analyzed in 4° latitude by 10° longitude cells at 96 km to obtain global contour maps of solar-tidal amplitudes and phases, and also mean winds. The solstices June–July (1993, December–January (1993–1994, and one equinox September–October (1994 are shown. 

    The 24-h diurnal tide that maximizes near the 20–25° latitude has significant seasonal changes with equinoctial maxima, and very clear longitudinal variability. Maxima are very clear over the oceans. In contrast, the 12-h semi-diurnal tides that maximize near the 40–55° latitude have very strong seasonal changes with winter maxima, and more modest longitudinal changes. The similarities with MLT (mesosphere-lower thermosphere radar observations (90 km and the GSWM (Global Scale Wave Model are very satisfactory. The mean winds are consistent with expectations and show clear poleward flow from summer to winter hemispheres in the solstices.

    Key words. Meteorology and atmospheric dynamics (middle atmosphere dynamics; waves and tides Radio science (remote sensing

  7. Measuring the impact of different brands of computer systems on the clinical consultation: a pilot study

    Directory of Open Access Journals (Sweden)

    Charlotte Refsum

    2008-07-01

    Conclusion This methodological development improves the reliability of our method for measuring the impact of different computer systems on the GP consultation. UAR added more objectivity to the observationof doctor_computer interactions. If larger studies were to reproduce the differences between computer systems demonstrated in this pilot it might be possible to make objective comparisons between systems.

  8. Measuring long impulse responses with pseudorandom sequences and sweep signals

    DEFF Research Database (Denmark)

    Torras Rosell, Antoni; Jacobsen, Finn

    2010-01-01

    In architectural acoustics, background noise, loudspeaker nonlinearities, and time variances are the most common disturbances that can compromise a measurement. The effects of such disturbances on measurement of long impulse responses with pseudorandom sequences (maximum-length sequences (MLS) an...

  9. Feasibility of megavoltage portal CT using an electronic portal imaging device (EPID) and a multi-level scheme algebraic reconstruction technique (MLS-ART)

    International Nuclear Information System (INIS)

    Guan, Huaiqun; Zhu, Yunping

    1998-01-01

    Although electronic portal imaging devices (EPIDs) are efficient tools for radiation therapy verification, they only provide images of overlapped anatomic structures. We investigated using a fluorescent screen/CCD-based EPID, coupled with a novel multi-level scheme algebraic reconstruction technique (MLS-ART), for a feasibility study of portal computed tomography (CT) reconstructions. The CT images might be useful for radiation treatment planning and verification. We used an EPID, set it to work at the linear dynamic range and collimated 6 MV photons from a linear accelerator to a slit beam of 1 cm wide and 25 cm long. We performed scans under a total of ∼200 monitor units (MUs) for several phantoms in which we varied the number of projections and MUs per projection. The reconstructed images demonstrated that using the new MLS-ART technique megavoltage portal CT with a total of 200 MUs can achieve a contrast detectibility of ∼2.5% (object size 5mmx5mm) and a spatial resolution of 2.5 mm. (author)

  10. Percutaneous Transtracheal Jet Ventilation with Various Upper Airway Obstruction

    Directory of Open Access Journals (Sweden)

    Tomoki Doi

    2015-01-01

    Full Text Available A “cannot-ventilate, cannot-intubate” situation is critical. In difficult airway management, transtracheal jet ventilation (TTJV has been recommended as an invasive procedure, but specialized equipment is required. However, the influence of upper airway resistance (UAR during TTJV has not been clarified. The aim of this study was to compare TTJV using a manual jet ventilator (MJV and the oxygen flush device of the anesthetic machine (AM. We made a model lung offering variable UAR by adjustment of tracheal tube size that can ventilate through a 14-G cannula. We measured side flow due to the Venturi effect during TTJV, inspired tidal volume (TVi, and expiratory time under various inspiratory times. No Venturi effect was detected during TTJV with either device. With the MJV, TVi tended to increase in proportion to UAR. With AM, significant variations in TVi was not detected with changes in any UAR. In conclusion, UAR influenced forward flow of TTJV in the model lung. The influence of choked flow from the Venturi effect was minimal under all UAR settings with the MJV, but the AM could not deliver sufficient flow.

  11. Clinical spectrum of females with HCCS mutation: from no clinical signs to a neonatal lethal form of the microphthalmia with linear skin defects (MLS) syndrome

    NARCIS (Netherlands)

    van Rahden, V.A.; Rau, I.; Fuchs, S.; Kosyna, F.K.; de Almeida, H.L.; Fryssira, H.; Isidor, B.; Jauch, A.; Joubert, M.; Lachmeijer, A.M.A.; Zweier, C.; Moog, U.; Kutsche, K.

    2014-01-01

    Background: Segmental Xp22.2 monosomy or a heterozygous HCCS mutation is associated with the microphthalmia with linear skin defects (MLS) or MIDAS (microphthalmia, dermal aplasia, and sclerocornea) syndrome, an X-linked disorder with male lethality. HCCS encodes the holocytochrome c-type synthase

  12. Ticosonde CFH at Costa Rica: A Seasonal Climatology of Tropical UT-LS Water Vapor and Inter-Comparisons with MLS and CALIPSO

    Science.gov (United States)

    Selkirk, Henry B.; Voemel, Holger; Avery, Melody; Rosenlof, Karen; Davis, Sean; Hurst, Dale; Schoeberl, Mark; Diaz, Jorge Andres; Morris, Gary

    2014-01-01

    Balloon sonde measurements of tropical water vapor using the Cryogenic Frostpoint Hygrometer were initiated in Costa Rica in July 2005 and have continued to the present day. Over the nine years through July 2014, the Ticosonde program has launched 174 CFH payloads, representing the longest-running and most extensive single-site balloon dataset for tropical water vapor. In this presentation we present a seasonal climatology for water vapor and ozone at Costa Rica and examine the frequency of upper tropospheric supersaturation with comparisons to cloud fraction and cloud ice water content observations from the Cloud Aerosol Lidar with Orthogonal Polarization (CALIOP) on the CALIPSO mission. We then make a critical comparison of these data to water vapor measurements from the MLS instrument on board Aura in light of recently published work for other sites. Finally, we examine time series of 2-km altitude averages in the upper troposphere-lower stratosphere at Costa Rica in light of anomalies and trends seen in various large-scale indices of tropical water vapor.

  13. Solar Cycle Variations of SABER CO2 and MLS H2O in the Mesosphere and Lower Thermosphere Region

    Science.gov (United States)

    Salinas, C. C. J.; Chang, L. C.; Liang, M. C.; Qian, L.; Yue, J.; Russell, J. M., III; Mlynczak, M. G.

    2017-12-01

    This work aims to present the solar cycle variations of SABER CO2 and MLS H2O in the Mesosphere and Lower Thermosphere region. These observations are then compared to SD-WACCM outputs of CO2 and H2O in order to understand their physical mechanisms. After which, we attempt to model their solar cycle variations using the default TIME-GCM and the TIME-GCM with MERRA reanalysis as lower-boundary conditions. Comparing the outputs of the default TIME-GCM and TIME-GCM with MERRA will give us insight into the importance of solar forcing and lower atmospheric forcing on the solar cycle variations of CO2 and H2O. The solar cycle influence in the parameters are calculated by doing a multiple linear regression with the F10.7 index. The solar cycle of SABER CO2 is reliable above 1e-2 mb and below 1e-3 mb. Preliminary results from the observations show that SABER CO2 has a stronger negative anomaly due to the solar cycle over the winter hemisphere. MLS H2O is reliable until 1e-2. Preliminary results from the observations show that MLS H2O also has a stronger negative anomaly due to the solar cycle over the winter hemisphere. Both SD-WACCM and the default TIME-GCM reproduce these stronger anomalies over the winter hemisphere. An analysis of the tendency equations in SD-WACCM and default TIME-GCM then reveal that for CO2, the stronger winter anomaly may be attributed to stronger downward transport over the winter hemisphere. For H2O, an analysis of the tendency equations in SD-WACCM reveal that the stronger winter anomaly may be attributed to both stronger downward transport and stronger photochemical loss. On the other hand, in the default TIME-GCM, the stronger winter anomaly in H2O may only be attributed to stronger downward transport. For both models, the stronger downward transport is attributed to enhanced stratospheric polar winter jet during solar maximum. Future work will determine whether setting the lower boundary conditions of TIME-GCM with MERRA will improve the match

  14. Variability in the Speed of the Brewer-Dobson Circulation as Observed by Aura/MLS

    Science.gov (United States)

    Flury, Thomas; Wu, Dong L.; Read, W. G.

    2013-01-01

    We use Aura/MLS stratospheric water vapour (H2O) measurements as tracer for dynamics and infer interannual variations in the speed of the Brewer-Dobson circulation (BDC) from 2004 to 2011. We correlate one-year time series of H2O in the lower stratosphere at two subsequent pressure levels (68 hPa, approx.18.8 km and 56 hPa, approx 19.9 km at the Equator) and determine the time lag for best correlation. The same calculation is made on the horizontal on the 100 hPa (approx 16.6 km) level by correlating the H2O time series at the Equator with the ones at 40 N and 40 S. From these lag coefficients we derive the vertical and horizontal speeds of the BDC in the tropics and extra-tropics, respectively. We observe a clear interannual variability of the vertical and horizontal branch. The variability reflects signatures of the Quasi Biennial Oscillation (QBO). Our measurements confirm the QBO meridional circulation anomalies and show that the speed variations in the two branches of the BDC are out of phase and fairly well anti-correlated. Maximum ascent rates are found during the QBO easterly phase. We also find that transport of H2O towards the Northern Hemisphere (NH) is on the average two times faster than to the Southern Hemisphere (SH) with a mean speed of 1.15m/s at 100 hPa. Furthermore, the speed towards the NH shows much more interannual variability with an amplitude of about 21% whilst the speed towards the SH varies by only 10 %. An amplitude of 21% is also observed in the variability of the ascent rate at the Equator which is on the average 0.2mm/s.

  15. Evidence of Convective Redistribution of Carbon Monoxide in Aura Tropospheric Emission Sounder (TES) and Microwave Limb Sounder (MLS) Observations

    Science.gov (United States)

    Manyin, Michael; Douglass, Anne; Schoeberl, Mark

    2010-01-01

    Vertical convective transport is a key element of the tropospheric circulation. Convection lofts air from the boundary layer into the free troposphere, allowing surface emissions to travel much further, and altering the rate of chemical processes such as ozone production. This study uses satellite observations to focus on the convective transport of CO from the boundary layer to the mid and upper troposphere. Our hypothesis is that strong convection associated with high rain rate regions leads to a correlation between mid level and upper level CO amounts. We first test this hypothesis using the Global Modeling Initiative (GMI) chemistry and transport model. We find the correlation is robust and increases as the precipitation rate (the strength of convection) increases. We next examine three years of CO profiles from the Tropospheric Emission Sounder (TES) and Microwave Limb Sounder (MLS) instruments aboard EOS Aura. Rain rates are taken from the Tropical Rainfall Measuring Mission (TRMM) 3B-42 multi-satellite product. Again we find a correlation between mid-level and upper tropospheric CO, which increases with rain rate. Our result shows the critical importance of tropical convection in coupling vertical levels of the troposphere in the transport of trace gases. The effect is seen most clearly in strong convective regions such as the Inter-tropical Convergence Zone.

  16. Research on Water Velocity Measurement of Reservoir Based on Pressure Sensor

    Directory of Open Access Journals (Sweden)

    Xiaoqiang Zhao

    2014-11-01

    Full Text Available To address the problem that pressure sensor can only measure the liquid level in reservoir, we designed a current velocity measurement system of reservoir based on pressure sensor, analyzed the error of current velocity measurement system, and proposed the error processing method and corresponding program. Several tests and experimental results show that in this measurement system, the liquid level measurement standard deviation is no more than 0.01 cm, and the current velocity measurement standard deviation is no more than 0.35 mL/s, which proves that the pressure sensor can measure both liquid level and current velocity synchronously.

  17. 20 Years of ClO Measurements in the Antarctic Lower Stratosphere

    Science.gov (United States)

    Nedoluha, Gerald E.; Connor, Brian J.; Mooney, Thomas; Barrett, James W.; Parrish, Alan; Gomez, R. Michael; Boyd, Ian; Allen, Douglas R.; Kotkamp, Michael; Kremser, Stefanie; hide

    2016-01-01

    We present 20 years (1996-2015) of austral springtime measurements of chlorine monoxide (ClO) over Antarctica from the Chlorine Oxide Experiment (ChlOEl) ground-based millimeter wave spectrometer at Scott Base, Antarctica, as well 12 years (2004-2015) of ClO measurements from the Aura Microwave Limb Sounder (MLS). From August onwards we observe a strong increase in lower stratospheric ClO, with a peak column amount usually occurring in early September. From mid-September onwards we observe a strong decrease in ClO. In order to study interannual differences, we focus on a 3-week period from 28 August to 17 September for each year and compare the average column ClO anomalies. These column ClO anomalies are shown to be highly correlated with the average ozone mass deficit for September and October of each year. We also show that anomalies in column ClO are strongly anti-correlated with 30 hPa temperature anomalies, both on a daily and an interannual timescale. Making use of this anti-correlation we calculate the linear dependence of the interannual variations in column C1O on interannual variations in temperature. By making use of this relationship, we can better estimate the underlying trend in the total chlorine (Cl(sub y) = HCl + ClONO2 + HOCl + 2 x Cl2 + 2 x Cl2+ ClO + Cl). The resultant trends in Cl(sub y), which determine the long-term trend in ClO, are estimated to be -0.5 +/-0.2, -1.40.9, and -0.60.4% per year, for zonal MLS, Scott Base MLS (both 2004-2015), and ChlOE (1996-2015) respectively. These trends are within 1sigma of trends in stratospheric Cl(sub y) previously found at other latitudes. The decrease in ClO is consistent with the trend expected from regulations enacted under the Montreal Protocol.

  18. Promoting Therapists' Use of Motor Learning Strategies within Virtual Reality-Based Stroke Rehabilitation.

    Science.gov (United States)

    Levac, Danielle E; Glegg, Stephanie M N; Sveistrup, Heidi; Colquhoun, Heather; Miller, Patricia; Finestone, Hillel; DePaul, Vincent; Harris, Jocelyn E; Velikonja, Diana

    2016-01-01

    Therapists use motor learning strategies (MLSs) to structure practice conditions within stroke rehabilitation. Virtual reality (VR)-based rehabilitation is an MLS-oriented stroke intervention, yet little support exists to assist therapists in integrating MLSs with VR system use. A pre-post design evaluated a knowledge translation (KT) intervention incorporating interactive e-learning and practice, in which 11 therapists learned how to integrate MLSs within VR-based therapy. Self-report and observer-rated outcome measures evaluated therapists' confidence, clinical reasoning and behaviour with respect to MLS use. A focus group captured therapists' perspectives on MLS use during VR-based therapy provision. The intervention improved self-reported confidence about MLS use as measured by confidence ratings (p behaviour change with respect to MLS use was noted (p = 0.092). Therapists favoured the strategy of transferring skills from VR to real-life tasks over employing a more comprehensive MLS approach. The KT intervention improved therapists' confidence but did not have an effect on clinical reasoning or behaviour with regard to MLS use during VR-based therapy.

  19. Performance investigation on the ultrasonic atomization liquid desiccant regeneration system

    International Nuclear Information System (INIS)

    Yang, Zili; Zhang, Kaisheng; Hwang, Yunho; Lian, Zhiwei

    2016-01-01

    Highlights: • We applied ultrasonic atomization technology to boost liquid desiccant regeneration. • We established a novel UARS and made a thorough study on its performance. • We developed a performance prediction model for UARS and validated its accuracy. • The necessary regeneration temperature dropped significantly (4.4 °C) in UARS. • Energy consumption for regenerating desiccant was reduced greatly (60.4%) in UARS. - Abstract: Liquid desiccant dehumidification systems have accumulated considerable research interest in recent years for their great energy saving potential in buildings. Within the system, the regenerator recovering liquid desiccant plays a major role in its performance. When the ultrasonic atomization technology is applied to atomize the desiccant solution into numerous tiny droplets with diameters around 50 μm, the regeneration process could be greatly enhanced. To validate this approach, a novel ultrasonic atomization liquid desiccant regeneration system (UARS) was studied in this work. An Ideal Regeneration Model (IRM) was developed to predict the regeneration performance of the UARS. Additionally, thorough experiments were carried out to validate the model under different operating conditions of the desiccant solution and air stream. The model predicted values and the experimental results coincided, with the average deviation less than 7.9%. The performance of UARS was compared with other regeneration systems from the open literature, while a case study was conducted for the power consumption and energy saving potential of UARS. It was found that the ultrasonic atomization technology enabled utilization of lower-grade energy for desiccant regeneration with the regeneration temperature lowered as much as 4.4 °C. In addition, a considerable energy saving potential of up to 23.4% could be achieved by the UARS for regenerating per unit mass flow of desiccant solution, while the power consumption of the ultrasonic atomization system

  20. Retrieval and satellite intercomparison of O3 measurements from ground-based FTIR Spectrometer at Equatorial Station: Addis Ababa, Ethiopia

    Directory of Open Access Journals (Sweden)

    T. von Clarmann

    2013-02-01

    Full Text Available Since May 2009, high-resolution Fourier Transform Infrared (FTIR solar absorption spectra have been recorded at Addis Ababa (9.01° N latitude, 38.76° E longitude, 2443 m altitude above sea level, Ethiopia. The vertical profiles and total column amounts of ozone (O3 are deduced from the spectra by using the retrieval code PROFFIT (V9.5 and regularly determined instrumental line shape (ILS. A detailed error analysis of the O3 retrieval is performed. Averaging kernels of the target gas shows that the major contribution to the retrieved information comes from the measurement. The degrees of freedom for signals is found to be 2.1 on average for the retrieval of O3 from the observed FTIR spectra. The ozone Volume Mixing Ratio (VMR profiles and column amounts retrieved from FTIR spectra are compared with the coincident satellite observations of Microwave Limb Sounding (MLS, Michelson Interferometer for Passive Atmospheric Sounding (MIPAS, Tropospheric Emission Spectrometer (TES, Ozone Monitoring Instrument (OMI, Atmospheric Infrared Sounding (AIRS and Global Ozone Monitoring Experiment (GOME-2 instruments. The mean relative differences in ozone profiles of FTIR from MLS and MIPAS are generally lower than 15% within the altitude range of 27 to 36 km, whereas difference from TES is lower than 1%. Comparisons of measurements of column amounts from the satellite and the ground-based FTIR show very good agreement as exhibited by relative differences within +0.2% to +2.8% for FTIR versus MLS and GOME-2; and −0.9 to −9.0% for FTIR versus OMI, TES and AIRS. The corresponding standard deviations are within 2.0 to 2.8% for FTIR versus MLS and GOME-2 comparisons whereas that of FTIR versus OMI, TES and AIRS are within 3.5 to 7.3%. Thus, the retrieved O3 VMR and column amounts from a tropical site, Addis Ababa, is found to exhibit very good agreement with all coincident satellite observations over an approximate 3-yr period.

  1. Project installation the large equipment in line system in Brazil. Gas export line valve P-40 FPSO-MLS. Field Marlim Sul, Campos Basin, Brazil; Operacao de instalacao do maior equipamento no sistema in line ja realizado no Brasil. Valvula do gasoduto P-40 X FPSO-MLS. Campo de Marlim Sul, Bacia de Campos, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Marcos Antonio Rodrigues; Fernandes, Paulo Tavares [PETROBRAS, Campos dos Goytacases, RJ (Brazil). Exploracao e Producao

    2005-07-01

    This work will approach the current level of development of the installation of connected underwater equipment to flexible lines in the underwater engineering operations in Campos' Basin. The project will show studies, analysis and simulations (through software developed by PETROBRAS) about the installation of the largest equipment laid in the 'in-line' system (connected to flexible lines) in Brazil - and one of the largest of the world: the ESDV (Emergency Shut Down Valve) of the gas pipeline P-40 x FPSO-MLS, in the South Marlim field, in Campos' Basin. This ESDV, of about 18.000 kg, 4 m height and 6,5 m length, has the purpose of assuring the safety conditions on the facilities, interrupting the gas flow exported for P-40 in case of emergency situations. Its installation opened a new alternative in releasing underwater equipment, using the ships that install the flexible lines. This operation occurred in June, 2004, and required the use of a second vessel for support and monitoring of the ESDV laying. The ESDV was installed at 400 m from FPSO-MLS, in a water depth of 1.137 m. This method shall be used broadly by the company in the implantation of the new units of Campos' Basin, and the upcoming studies must consider the gradual increase of the water depth in the new projects. This work will focus the technological development in this area, and one of its purposes is to foresee the future difficulties that can appear in the implantation of the production systems in deep and ultra-deep waters. (author)

  2. Brief Communication: Upper Air Relaxation in RACMO2 Significantly Improves Modelled Interannual Surface Mass Balance Variability in Antarctica

    Science.gov (United States)

    van de Berg, W. J.; Medley, B.

    2016-01-01

    The Regional Atmospheric Climate Model (RACMO2) has been a powerful tool for improving surface mass balance (SMB) estimates from GCMs or reanalyses. However, new yearly SMB observations for West Antarctica show that the modelled interannual variability in SMB is poorly simulated by RACMO2, in contrast to ERA-Interim, which resolves this variability well. In an attempt to remedy RACMO2 performance, we included additional upper-air relaxation (UAR) in RACMO2. With UAR, the correlation to observations is similar for RACMO2 and ERA-Interim. The spatial SMB patterns and ice-sheet-integrated SMB modelled using UAR remain very similar to the estimates of RACMO2 without UAR. We only observe an upstream smoothing of precipitation in regions with very steep topography like the Antarctic Peninsula. We conclude that UAR is a useful improvement for regional climate model simulations, although results in regions with steep topography should be treated with care.

  3. Variations in the free chlorine content of the stratosphere (1991-1997): Anthropogenic, volcanic, and methane influences

    International Nuclear Information System (INIS)

    Froidevaux, L.; Waters, J. W.; Read, W. G.; Connell, P. S.; Kinnison, D. E.; Russell, J. M. III

    2000-01-01

    Remote sensing of chlorine monoxide (ClO) by the Microwave Limb Sounder experiment aboard the Upper Atmosphere Research Satellite (UARS) has provided global measurements of variations in stratospheric free chlorine for 1991-1997. Linear trends were obtained from a multiple regression analysis of this data set at low latitudes and midlatitudes. ClO increases in the upper stratosphere (2 hPa) are significantly larger than expected from trends in chlorine source gases alone. Much of the upper stratospheric ClO variability can be explained by changes in CH 4 , as measured by the UARS Halogen Occultation Experiment. Decreasing ClO in the lower stratosphere is consistent with a relaxation from a chemically perturbed state attributed to the 1991 Mt. Pinatubo eruption. (c) 2000 American Geophysical Union

  4. Summer planetary-scale oscillations: aura MLS temperature compared with ground-based radar wind

    Directory of Open Access Journals (Sweden)

    C. E. Meek

    2009-04-01

    Full Text Available The advent of satellite based sampling brings with it the opportunity to examine virtually any part of the globe. Aura MLS mesospheric temperature data are analysed in a wavelet format for easy identification of possible planetary waves (PW and aliases masquerading as PW. A calendar year, 2005, of eastward, stationary, and westward waves at a selected latitude is shown in separate panels for wave number range −3 to +3 for period range 8 h to 30 days (d. Such a wavelet analysis is made possible by Aura's continuous sampling at all latitudes 82° S–82° N. The data presentation is suitable for examination of years of data. However this paper focuses on the striking feature of a "dish-shaped" upper limit to periods near 2 d in mid-summer, with longer periods appearing towards spring and fall, a feature also commonly seen in radar winds. The most probable cause is suggested to be filtering by the summer jet at 70–80 km, the latter being available from ground based medium frequency radar (MFR. Classically, the phase velocity of a wave must be greater than that of the jet in order to propagate through it. As an attempt to directly relate satellite and ground based sampling, a PW event of period 8d and wave number 2, which appears to be the original rather than an alias, is compared with ground based radar wind data. An appendix discusses characteristics of satellite data aliases with regard to their periods and amplitudes.

  5. The Multidimensional Loss Scale: validating a cross-cultural instrument for measuring loss.

    Science.gov (United States)

    Vromans, Lyn; Schweitzer, Robert D; Brough, Mark

    2012-04-01

    The Multidimensional Loss Scale (MLS) represents the first instrument designed specifically to index Experience of Loss Events and Loss Distress across multiple domains (cultural, social, material, and intrapersonal) relevant to refugee settlement. Recently settled Burmese adult refugees (N = 70) completed a questionnaire battery, including MLS items. Analyses explored MLS internal consistency, convergent and divergent validity, and factor structure. Cronbach alphas indicated satisfactory internal consistency for Experience of Loss Events (0.85) and Loss Distress (0.92), reflecting a unitary construct of multidimensional loss. Loss Distress did not correlate with depression or anxiety symptoms and correlated moderately with interpersonal grief and trauma symptoms, supporting divergent and convergent validity. Factor analysis provided preliminary support for a five-factor model: Loss of Symbolic Self, Loss of Interdependence, Loss of Home, Interpersonal Loss, and Loss of Intrapersonal Integrity. Received well by participants, the new scale shows promise for application in future research and practice.

  6. O2 atmospheric band measurements with WINDII: Performance of a narrow band filter/wide angle Michelson combination in space

    International Nuclear Information System (INIS)

    Ward, W.E.; Hersom, C.H.; Tai, C.C.; Gault, W.A.; Shepherd, G.G.; Solheim, B.H.

    1994-01-01

    Among the emissions viewed by the Wind Imaging Interferometer (WINDII) on the Upper Atmosphere Research Satellite (UARS) are selected lines in the (0-0) transition of the O2 atmospheric band. These lines are viewed simultaneously using a narrow band filter/wide-angle Michelson interferometer combination. The narrow band filter is used to separate the lines on the CCD (spectral-spatial scanning) and the Michelson used to modulate the emissions so that winds and rotational temperatures may be measured from the Doppler shifts and relative intensities of the lines. In this report this technique will be outlined and the on-orbit behavior since launch summarized

  7. Promoting Therapists' Use of Motor Learning Strategies within Virtual Reality-Based Stroke Rehabilitation.

    Directory of Open Access Journals (Sweden)

    Danielle E Levac

    Full Text Available Therapists use motor learning strategies (MLSs to structure practice conditions within stroke rehabilitation. Virtual reality (VR-based rehabilitation is an MLS-oriented stroke intervention, yet little support exists to assist therapists in integrating MLSs with VR system use.A pre-post design evaluated a knowledge translation (KT intervention incorporating interactive e-learning and practice, in which 11 therapists learned how to integrate MLSs within VR-based therapy. Self-report and observer-rated outcome measures evaluated therapists' confidence, clinical reasoning and behaviour with respect to MLS use. A focus group captured therapists' perspectives on MLS use during VR-based therapy provision.The intervention improved self-reported confidence about MLS use as measured by confidence ratings (p <0.001. Chart-Stimulated Recall indicated a moderate level of competency in therapists' clinical reasoning about MLSs following the intervention, with no changes following additional opportunities to use VR (p = .944. On the Motor Learning Strategy Rating Instrument, no behaviour change with respect to MLS use was noted (p = 0.092. Therapists favoured the strategy of transferring skills from VR to real-life tasks over employing a more comprehensive MLS approach.The KT intervention improved therapists' confidence but did not have an effect on clinical reasoning or behaviour with regard to MLS use during VR-based therapy.

  8. 20 years of ClO measurements in the Antarctic lower stratosphere

    Science.gov (United States)

    Nedoluha, Gerald E.; Connor, Brian J.; Mooney, Thomas; Barrett, James W.; Parrish, Alan; Gomez, R. Michael; Boyd, Ian; Allen, Douglas R.; Kotkamp, Michael; Kremser, Stefanie; Deshler, Terry; Newman, Paul; Santee, Michelle L.

    2016-08-01

    We present 20 years (1996-2015) of austral springtime measurements of chlorine monoxide (ClO) over Antarctica from the Chlorine Oxide Experiment (ChlOE1) ground-based millimeter wave spectrometer at Scott Base, Antarctica, as well 12 years (2004-2015) of ClO measurements from the Aura Microwave Limb Sounder (MLS). From August onwards we observe a strong increase in lower stratospheric ClO, with a peak column amount usually occurring in early September. From mid-September onwards we observe a strong decrease in ClO. In order to study interannual differences, we focus on a 3-week period from 28 August to 17 September for each year and compare the average column ClO anomalies. These column ClO anomalies are shown to be highly correlated with the average ozone mass deficit for September and October of each year. We also show that anomalies in column ClO are strongly anti-correlated with 30 hPa temperature anomalies, both on a daily and an interannual timescale. Making use of this anti-correlation we calculate the linear dependence of the interannual variations in column ClO on interannual variations in temperature. By making use of this relationship, we can better estimate the underlying trend in the total chlorine (Cly = HCl + ClONO2 + HOCl + 2 × Cl2 + 2 × Cl2O2 + ClO + Cl). The resultant trends in Cly, which determine the long-term trend in ClO, are estimated to be -0.5 ± 0.2, -1.4 ± 0.9, and -0.6 ± 0.4 % year-1, for zonal MLS, Scott Base MLS (both 2004-2015), and ChlOE (1996-2015) respectively. These trends are within 1σ of trends in stratospheric Cly previously found at other latitudes. The decrease in ClO is consistent with the trend expected from regulations enacted under the Montreal Protocol.

  9. Long-term trends in stratospheric ozone, temperature, and water vapor over the Indian region

    Science.gov (United States)

    Thankamani Akhil Raj, Sivan; Venkat Ratnam, Madineni; Narayana Rao, Daggumati; Venkata Krishna Murthy, Boddam

    2018-01-01

    We have investigated the long-term trends in and variabilities of stratospheric ozone, water vapor and temperature over the Indian monsoon region using the long-term data constructed from multi-satellite (Upper Atmosphere Research Satellite (UARS MLS and HALOE, 1993-2005), Aura Microwave Limb Sounder (MLS, 2004-2015), Sounding of the Atmosphere using Broadband Emission Radiometry (SABER, 2002-2015) on board TIMED (Thermosphere Ionosphere Mesosphere Energetics Dynamics)) observations covering the period 1993-2015. We have selected two locations, namely, Trivandrum (8.4° N, 76.9° E) and New Delhi (28° N, 77° E), covering northern and southern parts of the Indian region. We also used observations from another station, Gadanki (13.5° N, 79.2° E), for comparison. A decreasing trend in ozone associated with NOx chemistry in the tropical middle stratosphere is found, and the trend turned to positive in the upper stratosphere. Temperature shows a cooling trend in the stratosphere, with a maximum around 37 km over Trivandrum (-1.71 ± 0.49 K decade-1) and New Delhi (-1.15 ± 0.55 K decade-1). The observed cooling trend in the stratosphere over Trivandrum and New Delhi is consistent with Gadanki lidar observations during 1998-2011. The water vapor shows a decreasing trend in the lower stratosphere and an increasing trend in the middle and upper stratosphere. A good correlation between N2O and O3 is found in the middle stratosphere (˜ 10 hPa) and poor correlation in the lower stratosphere. There is not much regional difference in the water vapor and temperature trends. However, upper stratospheric ozone trends over Trivandrum and New Delhi are different. The trend analysis carried out by varying the initial year has shown significant changes in the estimated trend.

  10. Grafting, pruning, and the antipodal map on measured laminations

    OpenAIRE

    Dumas, David

    2006-01-01

    Grafting a measured lamination on a hyperbolic surface defines a self-map of Teichmuller space, which is a homeomorphism by a result of Scannell and Wolf. In this paper we study the large-scale behavior of pruning, which is the inverse of grafting. Specifically, for each conformal structure $X \\in \\T(S)$, pruning $X$ gives a map $\\ML(S) \\to \\T(S)$. We show that this map extends to the Thurston compactification of $\\T(S)$, and that its boundary values are the natural antipodal involution relat...

  11. A comprehensive overview of the climatological composition of the Asian summer monsoon anticyclone based on 10 years of Aura Microwave Limb Sounder measurements

    Science.gov (United States)

    Santee, M. L.; Manney, G. L.; Livesey, N. J.; Schwartz, M. J.; Neu, J. L.; Read, W. G.

    2017-05-01

    Intense deep convection associated with the Asian summer monsoon (ASM) lofts surface pollutants to the upper troposphere/lower stratosphere (UTLS), where strong winds and long chemical lifetimes allow intercontinental transport, affecting atmospheric composition around the globe. The Aura Microwave Limb Sounder (MLS), launched in 2004, makes simultaneous colocated measurements of trace gases and cloud ice water content (a proxy for deep convection) in the UTLS on a daily basis. Here we exploit the dense spatial and temporal coverage, long-term data record, extensive measurement suite, and insensitivity to aerosol and most clouds of Aura MLS to characterize the climatological (2005-2014) composition of the ASM anticyclone throughout its annual life cycle. We use version 4 MLS data to quantify spatial and temporal variations in both tropospheric (H2O, CO, CH3Cl, CH3CN, CH3OH) and stratospheric (O3, HNO3, HCl) tracers on four potential temperature surfaces (350-410 K). Inside the mature anticyclone, all species exhibit substantial changes, not only from their premonsoon distributions in the ASM region but also from their summertime distributions in the rest of the hemisphere. Different tracers exhibit dissimilar seasonal evolution, and the exact location and timing of their extreme values vary. Although individual aspects of the anticyclone have been described previously, we present a uniquely comprehensive overview of the climatological seasonal evolution of the ASM and its impact on UTLS composition. This work provides valuable context for planned in situ measurements as well as a benchmark for model evaluation and future investigations of interannual variability and long-term changes in monsoon processes.

  12. Characteristics of Water Vapor in the UTLS over the Tibetan Plateau Based on AURA/MLS Observations

    Directory of Open Access Journals (Sweden)

    Yi Sun

    2017-01-01

    Full Text Available Water vapor (WV has a vital effect on global climate change. Using satellite data observed by AURA/MLS and ERA-Interim reanalysis datasets, the spatial distributions and temporal variations of WV were analyzed. It was found that high WV content in the UTLS over the southern Tibetan Plateau is more apparent in summer, due to monsoon-induced strong upward motions. The WV content showed the opposite distribution at 100 hPa, though, during spring and winter. And a different distribution at 121 hPa indicated that the difference in WV content between the northern and southern plateau occurs between 121 and 100 hPa in spring and between 147 and 121 hPa in winter. In the UTLS, it diminishes rapidly with increase in altitude in these two seasons, and it shows a “V” structure in winter. There has been a weak increasing trend in WV at 100 hPa, but a downtrend at 147 and 215 hPa, during the past 12 years. At the latter two heights, the WV content in summer has been much higher than in other seasons. Furthermore, WV variation showed a rough wave structure in spring and autumn at 215 hPa. The variation of WV over the Tibetan Plateau is helpful in understanding the stratosphere-troposphere exchange (STE and climate change.

  13. 20 years of ClO measurements in the Antarctic lower stratosphere

    Directory of Open Access Journals (Sweden)

    G. E. Nedoluha

    2016-08-01

    Full Text Available We present 20 years (1996–2015 of austral springtime measurements of chlorine monoxide (ClO over Antarctica from the Chlorine Oxide Experiment (ChlOE1 ground-based millimeter wave spectrometer at Scott Base, Antarctica, as well 12 years (2004–2015 of ClO measurements from the Aura Microwave Limb Sounder (MLS. From August onwards we observe a strong increase in lower stratospheric ClO, with a peak column amount usually occurring in early September. From mid-September onwards we observe a strong decrease in ClO. In order to study interannual differences, we focus on a 3-week period from 28 August to 17 September for each year and compare the average column ClO anomalies. These column ClO anomalies are shown to be highly correlated with the average ozone mass deficit for September and October of each year. We also show that anomalies in column ClO are strongly anti-correlated with 30 hPa temperature anomalies, both on a daily and an interannual timescale. Making use of this anti-correlation we calculate the linear dependence of the interannual variations in column ClO on interannual variations in temperature. By making use of this relationship, we can better estimate the underlying trend in the total chlorine (Cly  =  HCl + ClONO2 + HOCl + 2  ×  Cl2 + 2  ×  Cl2O2 + ClO + Cl. The resultant trends in Cly, which determine the long-term trend in ClO, are estimated to be −0.5 ± 0.2, −1.4 ± 0.9, and −0.6 ± 0.4 % year−1, for zonal MLS, Scott Base MLS (both 2004–2015, and ChlOE (1996–2015 respectively. These trends are within 1σ of trends in stratospheric Cly previously found at other latitudes. The decrease in ClO is consistent with the trend expected from regulations enacted under the Montreal Protocol.

  14. Classification of Mls Point Clouds in Urban Scenes Using Detrended Geometric Features from Supervoxel-Based Local Contexts

    Science.gov (United States)

    Sun, Z.; Xu, Y.; Hoegner, L.; Stilla, U.

    2018-05-01

    In this work, we propose a classification method designed for the labeling of MLS point clouds, with detrended geometric features extracted from the points of the supervoxel-based local context. To achieve the analysis of complex 3D urban scenes, acquired points of the scene should be tagged with individual labels of different classes. Thus, assigning a unique label to the points of an object that belong to the same category plays an essential role in the entire 3D scene analysis workflow. Although plenty of studies in this field have been reported, this work is still a challenging task. Specifically, in this work: 1) A novel geometric feature extraction method, detrending the redundant and in-salient information in the local context, is proposed, which is proved to be effective for extracting local geometric features from the 3D scene. 2) Instead of using individual point as basic element, the supervoxel-based local context is designed to encapsulate geometric characteristics of points, providing a flexible and robust solution for feature extraction. 3) Experiments using complex urban scene with manually labeled ground truth are conducted, and the performance of proposed method with respect to different methods is analyzed. With the testing dataset, we have obtained a result of 0.92 for overall accuracy for assigning eight semantic classes.

  15. The SPARC water vapor assessment II: intercomparison of satellite and ground-based microwave measurements

    Science.gov (United States)

    Nedoluha, Gerald E.; Kiefer, Michael; Lossow, Stefan; Gomez, R. Michael; Kämpfer, Niklaus; Lainer, Martin; Forkman, Peter; Christensen, Ole Martin; Oh, Jung Jin; Hartogh, Paul; Anderson, John; Bramstedt, Klaus; Dinelli, Bianca M.; Garcia-Comas, Maya; Hervig, Mark; Murtagh, Donal; Raspollini, Piera; Read, William G.; Rosenlof, Karen; Stiller, Gabriele P.; Walker, Kaley A.

    2017-12-01

    As part of the second SPARC (Stratosphere-troposphere Processes And their Role in Climate) water vapor assessment (WAVAS-II), we present measurements taken from or coincident with seven sites from which ground-based microwave instruments measure water vapor in the middle atmosphere. Six of the ground-based instruments are part of the Network for the Detection of Atmospheric Composition Change (NDACC) and provide datasets that can be used for drift and trend assessment. We compare measurements from these ground-based instruments with satellite datasets that have provided retrievals of water vapor in the lower mesosphere over extended periods since 1996. We first compare biases between the satellite and ground-based instruments from the upper stratosphere to the upper mesosphere. We then show a number of time series comparisons at 0.46 hPa, a level that is sensitive to changes in H2O and CH4 entering the stratosphere but, because almost all CH4 has been oxidized, is relatively insensitive to dynamical variations. Interannual variations and drifts are investigated with respect to both the Aura Microwave Limb Sounder (MLS; from 2004 onwards) and each instrument's climatological mean. We find that the variation in the interannual difference in the mean H2O measured by any two instruments is typically ˜ 1%. Most of the datasets start in or after 2004 and show annual increases in H2O of 0-1 % yr-1. In particular, MLS shows a trend of between 0.5 % yr-1 and 0.7 % yr-1 at the comparison sites. However, the two longest measurement datasets used here, with measurements back to 1996, show much smaller trends of +0.1 % yr-1 (at Mauna Loa, Hawaii) and -0.1 % yr-1 (at Lauder, New Zealand).

  16. The SPARC water vapor assessment II: intercomparison of satellite and ground-based microwave measurements

    Directory of Open Access Journals (Sweden)

    G. E. Nedoluha

    2017-12-01

    Full Text Available As part of the second SPARC (Stratosphere–troposphere Processes And their Role in Climate water vapor assessment (WAVAS-II, we present measurements taken from or coincident with seven sites from which ground-based microwave instruments measure water vapor in the middle atmosphere. Six of the ground-based instruments are part of the Network for the Detection of Atmospheric Composition Change (NDACC and provide datasets that can be used for drift and trend assessment. We compare measurements from these ground-based instruments with satellite datasets that have provided retrievals of water vapor in the lower mesosphere over extended periods since 1996. We first compare biases between the satellite and ground-based instruments from the upper stratosphere to the upper mesosphere. We then show a number of time series comparisons at 0.46 hPa, a level that is sensitive to changes in H2O and CH4 entering the stratosphere but, because almost all CH4 has been oxidized, is relatively insensitive to dynamical variations. Interannual variations and drifts are investigated with respect to both the Aura Microwave Limb Sounder (MLS; from 2004 onwards and each instrument's climatological mean. We find that the variation in the interannual difference in the mean H2O measured by any two instruments is typically  ∼  1%. Most of the datasets start in or after 2004 and show annual increases in H2O of 0–1 % yr−1. In particular, MLS shows a trend of between 0.5 % yr−1 and 0.7 % yr−1 at the comparison sites. However, the two longest measurement datasets used here, with measurements back to 1996, show much smaller trends of +0.1 % yr−1 (at Mauna Loa, Hawaii and −0.1 % yr−1 (at Lauder, New Zealand.

  17. Upper Airway Resistance Syndrome Patients Have Worse Sleep Quality Compared to Mild Obstructive Sleep Apnea.

    Directory of Open Access Journals (Sweden)

    Luciana Balester Mello de Godoy

    Full Text Available To compare sleep quality and sustained attention of patients with Upper Airway Resistance Syndrome (UARS, mild Obstructive Sleep Apnea (OSA and normal individuals.UARS criteria were presence of excessive daytime sleepiness (Epworth Sleepiness Scale-ESS-≥ 10 and/or fatigue (Modified Fatigue Impact Scale-MFIS-≥ 38 associated to Apnea/hypopnea index (AHI ≤ 5 and Respiratory Disturbance Index (RDI > 5 events/hour of sleep or more than 30% of total sleep time with flow limitation. Mild OSA was considered if the presence of excessive daytime sleepiness (ESS ≥ 10 and/or fatigue (MFIS ≥ 38 associated to AHI ≥ 5 and ≤ 15 events/hour. "Control group" criteria were AHI < 5 events/hour and RDI ≤ 5 events/hour and ESS ≤ 9, without any sleep, clinical, neurological or psychiatric disorder. 115 individuals (34 UARS and 47 mild OSA patients and 34 individuals in "control group", adjusted for age, gender, body mass index (BMI and schooling years, performed sleep questionnaires and sustained attention evaluation. Psychomotor Vigilance Task (PVT was performed five times (each two hours from 8 a.m. to 4 p.m.UARS patients had worse sleep quality (Functional Outcomes of Sleep Questionnaire-FOSQ-and Pittsburgh Sleep Quality Index-PSQI: p < 0.05 and more fatigue than mild OSA patients (p = 0.003 and scored significantly higher in both Beck inventories than "control group" (p < 0.02. UARS patients had more lapses early in the morning (in time 1 compared to the results in the afternoon (time 5 than mild OSA (p = 0.02. Mild OSA patients had more lapses in times 2 than in time 5 compared to "control group" (p = 0.04.UARS patients have a worse sleep quality, more fatigue and a worse early morning sustained attention compared to mild OSA. These last had a worse sustained attention than controls.

  18. Utility Assessment Report for SPIDERS Phase 2: Ft. Carson (Rev 1.0)

    Energy Technology Data Exchange (ETDEWEB)

    Barr, Jonathan L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tuffner, Francis K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hadley, Mark D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Schneider, Kevin P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-01-01

    This document contains the Utility Assessment Report (UAR) for the Phase 2 operational Demonstration (OD) of the Smart Power Infrastructure Demonstration for Energy Reliability and Security (SPIDERS) Joint Capability Technology Demonstration (JCTD). The UAR for Phase 2 shows that the SPIDERS system was able to meet the requirements of the Implementation Directive at Ft. Carson.

  19. Treatment of upper airway resistance syndrome in adults: Where do we stand?

    Directory of Open Access Journals (Sweden)

    Luciana B.M. de Godoy

    2015-01-01

    Full Text Available Objective: To evaluate the available literature regarding Upper Airway Resistance Syndrome (UARS treatment. Methods: Keywords “Upper Airway Resistance Syndrome,” “Sleep-related Breathing Disorder treatment,” “Obstructive Sleep Apnea treatment” and “flow limitation and sleep” were used in main databases. Results: We found 27 articles describing UARS treatment. Nasal continuous positive airway pressure (CPAP has been the mainstay therapy prescribed but with limited effectiveness. Studies about surgical treatments had methodological limitations. Oral appliances seem to be effective but their efficacy is not yet established. Conclusion: Randomized controlled trials with larger numbers of patients and long-term follow-up are important to establish UARS treatment options.

  20. Characterization of molybdenum/silicon X-ray multilayers

    CERN Document Server

    Nayak, M; Lodha, G S; Shrivastava, A K; Tripathi, P; Sinha, A K; Sawhney, K J S; Nandedkar, R V

    2003-01-01

    Mo/Si multilayers (MLs) with variable Mo thickness were fabricated using electron beam evaporator. Percolation thickness for Mo was determined experimentally. MLs with Mo thickness below percolation show low reflectivity due to discontinuous nature of Mo film. As the number of layer pair increases, the interfacial roughness increases, due to increase in correlated roughness. Extreme ultra violet reflectivity was measured using synchrotron radiation. The fitting result reveals that the graded interface layer exists at each interface. Cross-sectional transmission electron microscopy has been done on some of these MLs.

  1. Long-term trends in stratospheric ozone, temperature, and water vapor over the Indian region

    Directory of Open Access Journals (Sweden)

    S. T. Akhil Raj

    2018-01-01

    Full Text Available We have investigated the long-term trends in and variabilities of stratospheric ozone, water vapor and temperature over the Indian monsoon region using the long-term data constructed from multi-satellite (Upper Atmosphere Research Satellite (UARS MLS and HALOE, 1993–2005, Aura Microwave Limb Sounder (MLS, 2004–2015, Sounding of the Atmosphere using Broadband Emission Radiometry (SABER, 2002–2015 on board TIMED (Thermosphere Ionosphere Mesosphere Energetics Dynamics observations covering the period 1993–2015. We have selected two locations, namely, Trivandrum (8.4° N, 76.9° E and New Delhi (28° N, 77° E, covering northern and southern parts of the Indian region. We also used observations from another station, Gadanki (13.5° N, 79.2° E, for comparison. A decreasing trend in ozone associated with NOx chemistry in the tropical middle stratosphere is found, and the trend turned to positive in the upper stratosphere. Temperature shows a cooling trend in the stratosphere, with a maximum around 37 km over Trivandrum (−1.71 ± 0.49 K decade−1 and New Delhi (−1.15 ± 0.55 K decade−1. The observed cooling trend in the stratosphere over Trivandrum and New Delhi is consistent with Gadanki lidar observations during 1998–2011. The water vapor shows a decreasing trend in the lower stratosphere and an increasing trend in the middle and upper stratosphere. A good correlation between N2O and O3 is found in the middle stratosphere (∼ 10 hPa and poor correlation in the lower stratosphere. There is not much regional difference in the water vapor and temperature trends. However, upper stratospheric ozone trends over Trivandrum and New Delhi are different. The trend analysis carried out by varying the initial year has shown significant changes in the estimated trend.

  2. Low-High and High-Low Biphasic Injection Forms in Computed Tomography Examinations of the Upper Abdomen

    International Nuclear Information System (INIS)

    Marti-Bonmati, L.; Arana, E.; Tobarra, E.; Sierra, C.

    2006-01-01

    Purpose: To analyze the influence of different biphasic and monophasic injection rate protocols in abdominal computed tomography (CT). Material and Methods: A randomized, consecutive, parallel group study was designed and conducted in 60 patients studied with the same CT helical protocol. Patients were randomly distributed into three groups: (A) monophasic (120 ml at 2.5 ml/s); (B) low-high biphasic (120 ml, first 60 ml at a rate of 2 ml/s, the other 60 ml at 2.5 ml/s); and (C) high-low biphasic (120 ml, first 60 ml at a rate of 2.5 ml/s, the other 60 ml at 2 ml/s). All patients were injected with 300 mg I/ml non-ionic contrast media at a fixed delay time of 55 s. Contrast enhancement efficacy was evaluated by attenuation coefficient measurements. Results: Although non-significant, monophasic protocol enhancements were higher than biphasic protocol enhancements in all measurements except aortic bifurcation (p = 0.003). At this level, biphasic protocols obtained an increased mean enhancement from 7.6% to 2.5% compared to monophasic protocols. Conclusion: Monophasic contrast agent injection in helical CT of the upper abdomen produces a higher enhancement of parenchymal and venous structures. No significant difference was observed between low-high and high-low biphasic protocols

  3. Irradiation Effect of Argon Ion on Interfacial Structure Fe(2nm/Si(tsi=0.5-2 nm Multilayer thin Film

    Directory of Open Access Journals (Sweden)

    S. Purwanto

    2010-04-01

    Full Text Available Investigation includes formation of interfacial structure of Fe(2nm/Si(tSi= 0.5-2 nm multilayer thin film and the behavior of antiferromagnetic coupling between Fe layers due to Argon ion irradiation was investigated. [Fe(2nm/Si]30 multilayers (MLs with a thickness of Si spacer 0.5 - 2 nanometer were prepared on n-type (100 Si substrate by the helicon plasma sputtering method. Irradiation were performed using 400keV Ar ion to investigate the behavior of magnetic properties of the Fe/Si MLs. The magnetization measurements of Fe/Si MLs after 400keV Ar ion irradiation show the degradation of antiferromagnetic behavior of Fe layers depend on the ion doses. The Magnetoresistance (MR measurements using by Four Point Probe (FPP method also confirm that MR ratio decrease after ion irradiation. X-ray diffraction (XRD patterns indicate that the intensity of a satellite peak induced by a superlattice structure does not change within the range of ion dose. These results imply that the surface of interface structures after ion irradiation become rough although the layer structures are maintained. Therefore, it is considered that the MR properties of Fe/Si MLs also are due to the metallic superlattice structures such as Fe/Cr and Co/Cu MLs.

  4. Upper airway resistance syndrome.

    Science.gov (United States)

    Montserrat, J M; Badia, J R

    1999-03-01

    This article reviews the clinical picture, diagnosis and management of the upper airway resistance syndrome (UARS). Presently, there is not enough data on key points like the frequency of UARS and the morbidity associated with this condition. Furthermore, the existence of LIARS as an independent sleep disorder and its relation with snoring and obstructive events is in debate. The diagnosis of UARS is still a controversial issue. The technical limitations of the classic approach to monitor airflow with thermistors and inductance plethysmography, as well as the lack of a precise definition of hypopnea, may have led to a misinterpretation of UARS as an independent diagnosis from the sleep apnea/hypopnea syndrome. The diagnosis of this syndrome can be missed using a conventional polysomnographic setting unless appropriate techniques are applied. The use of an esophageal balloon to monitor inspiratory effort is currently the gold standard. However, other sensitive methods such as the use of a pneumotachograph and, more recently, nasal cannula/pressure transducer systems or on-line monitoring of respiratory impedance with the forced oscillation technique may provide other interesting possibilities. Recognition and characterization of this subgroup of patients within sleep breathing disorders is important because they are symptomatic and may benefit from treatment. Management options to treat UARS comprise all those currently available for sleep apnea/hypopnea syndrome (SAHS). However, the subset of patients classically identified as LIARS that exhibit skeletal craneo-facial abnormalities might possibly obtain further benefit from maxillofacial surgery.

  5. Distribution and transport of water vapor in the UTLS over the Tibetan Plateau as inferred from the MLS satellite data and WRF model simulations

    Science.gov (United States)

    Jain, S.; Kar, S. C.

    2016-12-01

    Water vapor is an important minor constituent in the lower stratosphere as it influences the stratospheric chemistry and total radiation budget. The spatial distribution of water vapor mixing ratio (WVMR) obtained from Aura Microwave Limb Sounder (MLS) satellite at 100 hPa level shows prominent maxima over the Tibetan Plateau during August 2015. The Asian monsoon upper level anticyclone is also known to occur over this region during this period. The Indian Meteorological Department (IMD) and National Centre of Medium Range Weather Forecasting (NCMRWF) observed daily gridded rainfall data shows moderate to heavy rainfall over the Tibetan Plateau, suggesting active convection from 26 July to 10 August 2015. The atmospheric conditions are simulated over the Asian region for the 15-day period using the Weather Research Forecasting (WRF) model. The simulations are carried out using two nested domains with resolution of 12 km and 4 km. The initial and boundary conditions are taken from the NGFS (up-graded version of the NCEP GFS) data. The WRF WVMR profiles are observed to be comparatively moist than the MLS profiles in the UTLS region over the Tibetan Plateau. This may be due to the relatively higher temperatures (1-2 K) simulated in the WRF model near 100 hPa level. It is noted that the WRF model has a drying tendency at all the levels. The UTLS WVMR and temperatures show poor sensitivity to the convective schemes. The parent domain and the explicit convective scheme simulate almost same moisture over time in the inner domain. The cloud micro-physics is observed to play a rather important role in controlling the UTLS water vapor content. The WSM-6 convective scheme is observed to simulate the UTLS moisture comparatively well and therefore the processes associated with the formation of ice, snow and graupel formation may be of much more importance in controlling the UTLS WVMR in the WRF model. The 24 hr, 48 hr and 72 hr forecast averaged for the 15-day period shows that

  6. Technical note: Evaluation of the simultaneous measurements of mesospheric OH, HO2, and O3 under a photochemical equilibrium assumption - a statistical approach

    Science.gov (United States)

    Kulikov, Mikhail Y.; Nechaev, Anton A.; Belikovich, Mikhail V.; Ermakova, Tatiana S.; Feigin, Alexander M.

    2018-05-01

    This Technical Note presents a statistical approach to evaluating simultaneous measurements of several atmospheric components under the assumption of photochemical equilibrium. We consider simultaneous measurements of OH, HO2, and O3 at the altitudes of the mesosphere as a specific example and their daytime photochemical equilibrium as an evaluating relationship. A simplified algebraic equation relating local concentrations of these components in the 50-100 km altitude range has been derived. The parameters of the equation are temperature, neutral density, local zenith angle, and the rates of eight reactions. We have performed a one-year simulation of the mesosphere and lower thermosphere using a 3-D chemical-transport model. The simulation shows that the discrepancy between the calculated evolution of the components and the equilibrium value given by the equation does not exceed 3-4 % in the full range of altitudes independent of season or latitude. We have developed a statistical Bayesian evaluation technique for simultaneous measurements of OH, HO2, and O3 based on the equilibrium equation taking into account the measurement error. The first results of the application of the technique to MLS/Aura data (Microwave Limb Sounder) are presented in this Technical Note. It has been found that the satellite data of the HO2 distribution regularly demonstrate lower altitudes of this component's mesospheric maximum. This has also been confirmed by model HO2 distributions and comparison with offline retrieval of HO2 from the daily zonal means MLS radiance.

  7. Reflection of femtosecond pulses from soft X-ray free-electron laser by periodical multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Ksenzov, D.; Grigorian, S.; Pietsch, U. [Faculty of Physics, University of Siegen (Germany); Hendel, S.; Bienert, F.; Sacher, M.D.; Heinzmann, U. [Faculty of Physics, University of Bielefeld (Germany)

    2009-08-15

    Recent experiments on a soft X-ray free-electron laser (FEL) source (FLASH in Hamburg) have shown that multilayers (MLs) can be used as optical elements for highly intense X-ray irradiation. An effort to find most appropriate MLs has to consider the femtosecond time structure and the particular photon energy of the FEL. In this paper we have analysed the time response of 'low absorbing' MLs (e.g. such as La/B{sub 4}C) as a function of the number of periods. Interaction of a pulse train of Gaussian shaped sub-pulses using a realistic ML grown by electron-beam evaporation technique has been analysed in the soft-X-ray range. The structural parameters of the MLs were obtained by reflectivity measurements at BESSY II and subsequent profile fittings. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  8. Test field for airborne laser scanning in Finland

    Science.gov (United States)

    Ahokas, E.; Kaartinen, H.; Kukko, A.; Litkey, P.

    2014-11-01

    Airborne laser scanning (ALS) is a widely spread operational measurement tool for obtaining 3D coordinates of the ground surface. There is a need for calibrating the ALS system and a test field for ALS was established at the end of 2013. The test field is situated in the city of Lahti, about 100 km to the north of Helsinki. The size of the area is approximately 3.5 km × 3.2 km. Reference data was collected with a mobile laser scanning (MLS) system assembled on a car roof. Some streets were measured both ways and most of them in one driving direction only. The MLS system of the Finnish Geodetic Institute (FGI) consists of a navigation system (NovAtel SPAN GNSS-IMU) and a laser scanner (FARO Focus3D 120). In addition to the MLS measurements more than 800 reference points were measured using a Trimble R8 VRS-GNSS system. Reference points are along the streets, on parking lots, and white pedestrian crossing line corners which can be used as reference targets. The National Land Survey of Finland has already used this test field this spring for calibrating their Leica ALS-70 scanner. Especially it was easier to determine the encoder scale factor parameter using this test field. Accuracy analysis of the MLS points showed that the point height RMSE is 2.8 cm and standard deviation is 2.6 cm. Our purpose is to measure both more MLS data and more reference points in the test field area to get a better spatial coverage. Calibration flight heights are planned to be 1000 m and 2500 m above ground level. A cross pattern, southwest-northeast and northwest-southeast, will be flown both in opposite directions.

  9. Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system.

    Science.gov (United States)

    Tsujimoto, Yukio; Nose, Yorihito; Ohba, Kenkichi

    2003-01-01

    The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. We carried out a basal experiment measuring flow velocity in model urethras of 4.5-8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 +/- 4.3 mL/s (mean +/- SD; range, 18.4-1.3 mL/s), urethral diameter was 7.3 +/- 3.0 mm (mean +/- SD; range, 18.7-4.3 mm) and urinary velocity was 69.4 +/- 43.6 (mean +/- SD; range, 181.3-0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.

  10. Tropospheric Column Ozone Response to ENSO in GEOS-5 Assimilation of OMI and MLS Ozone Data

    Science.gov (United States)

    Olsen, Mark A.; Wargan, Krzysztof; Pawson, Steven

    2016-01-01

    We use GEOS-5 analyses of Ozone Monitoring Instrument (OMI) and Microwave Limb Sounder (MLS) ozone observations to investigate the magnitude and spatial distribution of the El Nino Southern Oscillation (ENSO) influence on tropospheric column ozone (TCO) into the middle latitudes. This study provides the first explicit spatially resolved characterization of the ENSO influence and demonstrates coherent patterns and teleconnections impacting the TCO in the extratropics. The response is evaluated and characterized by both the variance explained and sensitivity of TCO to the Nino 3.4 index. The tropospheric response in the tropics agrees well with previous studies and verifies the analyses. A two-lobed response symmetric about the Equator in the western Pacific/Indonesian region seen in some prior studies and not in others is confirmed here. This two-lobed response is consistent with the large-scale vertical transport. We also find that the large-scale transport in the tropics dominates the response compared to the small-scale convective transport. The ozone response is weaker in the middle latitudes, but a significant explained variance of the TCO is found over several small regions, including the central United States. However, the sensitivity of TCO to the Nino 3.4 index is statistically significant over a large area of the middle latitudes. The sensitivity maxima and minima coincide with anomalous anti-cyclonic and cyclonic circulations where the associated vertical transport is consistent with the sign of the sensitivity. Also, ENSO related changes to the mean tropopause height can contribute significantly to the midlatitude response. Comparisons to a 22-year chemical transport model simulation demonstrate that these results from the 9- year assimilation are representative of the longer term. This investigation brings insight to several seemingly disparate prior studies of the El Nino influence on tropospheric ozone in the middle latitudes.

  11. Tropospheric column ozone response to ENSO in GEOS-5 assimilation of OMI and MLS ozone data

    Directory of Open Access Journals (Sweden)

    M. A. Olsen

    2016-06-01

    Full Text Available We use GEOS-5 analyses of Ozone Monitoring Instrument (OMI and Microwave Limb Sounder (MLS ozone observations to investigate the magnitude and spatial distribution of the El Niño Southern Oscillation (ENSO influence on tropospheric column ozone (TCO into the middle latitudes. This study provides the first explicit spatially resolved characterization of the ENSO influence and demonstrates coherent patterns and teleconnections impacting the TCO in the extratropics. The response is evaluated and characterized by both the variance explained and sensitivity of TCO to the Niño 3.4 index. The tropospheric response in the tropics agrees well with previous studies and verifies the analyses. A two-lobed response symmetric about the Equator in the western Pacific/Indonesian region seen in some prior studies and not in others is confirmed here. This two-lobed response is consistent with the large-scale vertical transport. We also find that the large-scale transport in the tropics dominates the response compared to the small-scale convective transport. The ozone response is weaker in the middle latitudes, but a significant explained variance of the TCO is found over several small regions, including the central United States. However, the sensitivity of TCO to the Niño 3.4 index is statistically significant over a large area of the middle latitudes. The sensitivity maxima and minima coincide with anomalous anti-cyclonic and cyclonic circulations where the associated vertical transport is consistent with the sign of the sensitivity. Also, ENSO related changes to the mean tropopause height can contribute significantly to the midlatitude response. Comparisons to a 22-year chemical transport model simulation demonstrate that these results from the 9-year assimilation are representative of the longer term. This investigation brings insight to several seemingly disparate prior studies of the El Niño influence on tropospheric ozone in the middle latitudes.

  12. Pressure broadening measurement of submillimeter-wave lines of O3

    International Nuclear Information System (INIS)

    Yamada, M.M.; Amano, T.

    2005-01-01

    The pressure broadening coefficients and their temperature dependences for two submillimeter-wave transitions of ozone, one being monitored with Odin and the other to be monitored with JEM/SMILES and EOS-MLS, have been determined by using a BWO based submillimeter-wave spectrometer. The measurements have also been extended to one of the symmetric isotopic species, 16 O 18 O 16 O. The isotopic species is observed in natural abundance and as a consequence the temperature dependence is not determined due to weak signal intensity. The pressure broadening parameters are determined with better than 1% accuracy, while the temperature dependence exponents are obtained within 1.5-3% accuracy for the normal species transitions

  13. VoIP Quality Measurements in a Multilevel Secure (MLS) Environment

    National Research Council Canada - National Science Library

    Adams, Jr, Coy M

    2008-01-01

    Voice over Internet Protocol (VoIP) is growing in popularity in the civilian and military communities due to its low cost and the management advantages it offers over traditional Public Switched Telephone Networks (PSTN) phone systems...

  14. Retrieval of NO2 stratospheric profiles from ground-based zenith-sky uv-visible measurements at 60°N

    Science.gov (United States)

    Hendrick, F.; van Roozendael, M.; Lambert, J.-C.; Fayt, C.; Hermans, C.; de Mazière, M.

    2003-04-01

    Nitrogen dioxide (NO_2) plays an important role in controlling ozone abundances in the stratosphere, either directly through the NOx (NO+NO_2) catalytic cycle, either indirectly by reaction with the radical ClO to form the reservoir species ClONO_2. In this presentation, NO_2 stratospheric profiles are retrieved from ground-based UV-visible NO_2 slant column abundances measured since 1998 at the complementary NDSC station of Harestua (Norway, 60^oN). The retrieval algorithm is based on the Rodgers optimal estimation inversion method and a forward model consisting in the IASB-BIRA stacked box photochemical model PSCBOX coupled to the radiative transfer package UVspec/DISORT. This algorithm has been applied to a set of about 50 sunrises and sunsets for which spatially and temporally coincident NO_2 measurements made by the HALOE (Halogen Occultation Experiment) instrument on board the Upper Atmosphere Research Satellite (UARS) are available. The consistency between retrieved and HALOE profiles is discussed in term of the different seasonal conditions investigated which are spring with and without chlorine activation, summer, and fall.

  15. Uranium from phosphates in the United Arab Republic

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1959-04-15

    In response to a request from the UAR Government, the IAEA sent a Soviet expert, to make an on-the-spot study of data on the mining and processing of phosphates in the UAR and to examine the possibility of recovering uranium from the phosphate ores. In his report to the IAEA Director General, he has listed the following conclusions: 1.The uranium content of run-of-the-mine phosphoric ores in the United Arab Republic is very low and the recovery of uranium from them is therefore hardly likely to be an economic proposition. 2. It is essential to press on with prospecting work in order to discover richer uranium deposits and regions of phosphoritic ores. 3. It is essential to organize scientific research work on the recovery of uranium from the various types of uranium-bearing phosphoritic ores in the United Arab Republic, using mechanical concentrating methods and chemical processing methods. 4. The Agency could assist in carrying out this work either by sending as many technicians as a required to help in planning and undertaking the research work in the UAR or by getting appropriate Member States to carry out this work on preliminary samples of ore with the participation of representatives of the UAR

  16. Upper Airway Resistance Syndrome Patients Have Worse Sleep Quality Compared to Mild Obstructive Sleep Apnea.

    Science.gov (United States)

    de Godoy, Luciana Balester Mello; Luz, Gabriela Pontes; Palombini, Luciana Oliveira; E Silva, Luciana Oliveira; Hoshino, Wilson; Guimarães, Thaís Moura; Tufik, Sergio; Bittencourt, Lia; Togeiro, Sonia Maria

    2016-01-01

    To compare sleep quality and sustained attention of patients with Upper Airway Resistance Syndrome (UARS), mild Obstructive Sleep Apnea (OSA) and normal individuals. UARS criteria were presence of excessive daytime sleepiness (Epworth Sleepiness Scale-ESS-≥ 10) and/or fatigue (Modified Fatigue Impact Scale-MFIS-≥ 38) associated to Apnea/hypopnea index (AHI) ≤ 5 and Respiratory Disturbance Index (RDI) > 5 events/hour of sleep or more than 30% of total sleep time with flow limitation. Mild OSA was considered if the presence of excessive daytime sleepiness (ESS ≥ 10) and/or fatigue (MFIS ≥ 38) associated to AHI ≥ 5 and ≤ 15 events/hour. "Control group" criteria were AHI sleep, clinical, neurological or psychiatric disorder. 115 individuals (34 UARS and 47 mild OSA patients and 34 individuals in "control group"), adjusted for age, gender, body mass index (BMI) and schooling years, performed sleep questionnaires and sustained attention evaluation. Psychomotor Vigilance Task (PVT) was performed five times (each two hours) from 8 a.m. to 4 p.m. UARS patients had worse sleep quality (Functional Outcomes of Sleep Questionnaire-FOSQ-and Pittsburgh Sleep Quality Index-PSQI: p sleep quality, more fatigue and a worse early morning sustained attention compared to mild OSA. These last had a worse sustained attention than controls.

  17. Observation of the exhaust plume from the space shuttle main engines using the microwave limb sounder

    Directory of Open Access Journals (Sweden)

    H. C. Pumphrey

    2011-01-01

    Full Text Available A space shuttle launch deposits 700 tonnes of water in the atmosphere. Some of this water is released into the upper mesosphere and lower thermosphere where it may be directly detected by a limb sounding satellite instrument. We report measurements of water vapour plumes from shuttle launches made by the Microwave Limb Sounder (MLS on the Aura satellite. Approximately 50%–65% of shuttle launches are detected by MLS. The signal appears at a similar level across the upper 10 km of the MLS limb scan, suggesting that the bulk of the observed water is above the top of the scan. Only a small fraction at best of smaller launches (Ariane 5, Proton are detected. We conclude that the sensitivity of MLS is only just great enough to detect a shuttle sized launch, but that a suitably designed instrument of the same general type could detect the exhausts from a large proportion of heavy-lift launches.

  18. Evaluation of exhaled nitric oxide in schoolchildren at different exhalation flow rates.

    Science.gov (United States)

    Pedroletti, Christophe; Zetterquist, Wilhelm; Nordvall, Lennart; Alving, Kjell

    2002-09-01

    Nitric oxide (NO) in exhaled air is believed to reflect allergic inflammation in the airways. Measured levels of exhaled NO vary with the exhaled flow rate, which therefore must be standardized. The aim of this study was to estimate the optimal exhalation flow rate when measuring NO in exhaled air. We studied 15 asthmatic children (8-18 y) with elevated NO levels and 15 age-matched controls and focused on how the quality of the NO curve profile, the discriminatory power, and the reproducibility were influenced by the exhalation flow rate. We used an on-line system for NO measurements at six different exhalation flow rates in the interval of 11-382 mL/s. The fraction of exhaled nitric oxide (FENO) was highly flow-dependent as was expected. Intermediate flow rates yielded a flat and stable NO plateau and were considerably easier to interpret than those obtained at the highest and lowest flow rates. The ratio of FENO between asthmatics and controls was lower at higher flow rates and a considerable overlap in NO values was demonstrated at all flow rates except 50 mL/s. The reproducibility was much lower at more extreme flow rates and was best at 50 mL/s. We conclude that a target exhalation flow rate of approximately 50 mL/s is to be preferred using the single-breath method for on-line NO measurements in schoolchildren.

  19. 2-O-α-D-glucosylglycerol phosphorylase from Bacillus selenitireducens MLS10 possessing hydrolytic activity on β-D-glucose 1-phosphate.

    Directory of Open Access Journals (Sweden)

    Takanori Nihira

    Full Text Available The glycoside hydrolase family (GH 65 is a family of inverting phosphorylases that act on α-glucosides. A GH65 protein (Bsel_2816 from Bacillus selenitireducens MLS10 exhibited inorganic phosphate (Pi-dependent hydrolysis of kojibiose at the rate of 0.43 s(-1. No carbohydrate acted as acceptor for the reverse phosphorolysis using β-D-glucose 1-phosphate (βGlc1P as donor. During the search for a suitable acceptor, we found that Bsel_2816 possessed hydrolytic activity on βGlc1P with a k cat of 2.8 s(-1; moreover, such significant hydrolytic activity on sugar 1-phosphate had not been reported for any inverting phosphorylase. The H2 (18O incorporation experiment and the anomeric analysis during the hydrolysis of βGlc1P revealed that the hydrolysis was due to the glucosyl-transferring reaction to a water molecule and not a phosphatase-type reaction. Glycerol was found to be the best acceptor to generate 2-O-α-D-glucosylglycerol (GG at the rate of 180 s(-1. Bsel_2816 phosphorolyzed GG through sequential Bi-Bi mechanism with a k cat of 95 s(-1. We propose 2-O-α-D-glucopyranosylglycerol: phosphate β-D-glucosyltransferase as the systematic name and 2-O-α-D-glucosylglycerol phosphorylase as the short name for Bsel_2816. This is the first report describing a phosphorylase that utilizes polyols, and not carbohydrates, as suitable acceptor substrates.

  20. Clinical phenotype of South-East Asian temporomandibular disorder patients with upper airway resistance syndrome.

    Science.gov (United States)

    Tay, D K L; Pang, K P

    2018-01-01

    Clinical and radiographic characteristics of a subset of South East Asian temporomandibular disorder (TMD) patients with comorbid upper airway resistance syndrome (UARS) were documented in a multi-center prospective series of 86 patients (26 men and 60 women / mean age 35.7 years). All had excessive daytime sleepiness, high arousal index and Apnoea-Hypopnoea Index (AHI) temporomandibular joint (TMJ) arthralgia while 90·7% reported sleep bruxism (SB). Unlike patients with obstructive sleep apnoea (OSA), hypertension was uncommon (4·7%) while depression was prevalent at 68·6% with short REM latency of 25% documented in 79·6% and 57·6% of these depressed patients, respectively. 65·1% displayed a posteriorly displaced condyle at maximum intercuspation with or without TMJ clicking. Most exhibited a forward head posture (FHP) characterised by loss of normal cervical lordosis (80·2%), C0-C1 narrowing (38·4%) or an elevated hyoid position (50%), and 91·9% had nasal congestion. We postulate the TMD-UARS phenotype may have originally developed as an adaptive response to 'awake' disordered breathing during growth. Patients with persistent TMD and/or reporting SB should be screened for UARS and chronic nasal obstruction, especially when they also present with FHP. The lateral cephalogram is a useful tool in the differentiation of UARS from other OSA phenotypes. © 2017 John Wiley & Sons Ltd.

  1. Measurements of exhaled nitric oxide in healthy subjects age 4 to 17 years

    DEFF Research Database (Denmark)

    Buchvald, Frederik; Baraldi, Eugenio; Carraro, Silvia

    2005-01-01

    to almost 100% from the age of 10 years. The repeatability of 3 approved measurements was 1.6 ppb (95% CI, 1.49-1.64 ppb). CONCLUSION: FE NO in healthy children is below 15 to 25 ppb depending on age and self-reported atopy. Measurement of FE NO by NIOX is simple and safe and has a good repeatability...... NO was measured in healthy subjects of 4 to 17 years according to American Thoracic Society guidelines (single breath online, exhalation flow 50 mL/s) with a chemiluminescence analyzer (NIOX Exhaled Nitric Oxide Monitoring System, Aerocrine, Sweden) in 3 European and 2 US centers. Each child performed 3...... NO in 405 children was 9.7 ppb, and the upper 95% confidence limit was 25.2 ppb. FE NO increased significantly with age, and higher FE NO was seen in children with self-reported rhinitis/conjunctivitis or hay fever. The success rate was age-dependent and improved from 40% in the children 4 years old...

  2. Revising the retrieval technique of a long-term stratospheric HNO{sub 3} data set. From a constrained matrix inversion to the optimal estimation algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Fiorucci, I.; Muscari, G. [Istituto Nazionale di Geofisica e Vulcanologia, Rome (Italy); De Zafra, R.L. [State Univ. of New York, Stony Brook, NY (United States). Dept. of Physics and Astronomy

    2011-07-01

    The Ground-Based Millimeter-wave Spectrometer (GBMS) was designed and built at the State University of New York at Stony Brook in the early 1990s and since then has carried out many measurement campaigns of stratospheric O{sub 3}, HNO{sub 3}, CO and N{sub 2}O at polar and mid-latitudes. Its HNO{sub 3} data set shed light on HNO{sub 3} annual cycles over the Antarctic continent and contributed to the validation of both generations of the satellite-based JPL Microwave Limb Sounder (MLS). Following the increasing need for long-term data sets of stratospheric constituents, we resolved to establish a long-term GMBS observation site at the Arctic station of Thule (76.5 N, 68.8 W), Greenland, beginning in January 2009, in order to track the long- and short-term interactions between the changing climate and the seasonal processes tied to the ozone depletion phenomenon. Furthermore, we updated the retrieval algorithm adapting the Optimal Estimation (OE) method to GBMS spectral data in order to conform to the standard of the Network for the Detection of Atmospheric Composition Change (NDACC) microwave group, and to provide our retrievals with a set of averaging kernels that allow more straightforward comparisons with other data sets. The new OE algorithm was applied to GBMS HNO{sub 3} data sets from 1993 South Pole observations to date, in order to produce HNO{sub 3} version 2 (v2) profiles. A sample of results obtained at Antarctic latitudes in fall and winter and at mid-latitudes is shown here. In most conditions, v2 inversions show a sensitivity (i.e., sum of column elements of the averaging kernel matrix) of 100{+-}20% from 20 to 45 km altitude, with somewhat worse (better) sensitivity in the Antarctic winter lower (upper) stratosphere. The 1{sigma} uncertainty on HNO{sub 3} v2 mixing ratio vertical profiles depends on altitude and is estimated at {proportional_to}15% or 0.3 ppbv, whichever is larger. Comparisons of v2 with former (v1) GBMS HNO{sub 3} vertical profiles

  3. A 40 Year Time Series of SBUV Observations: the Version 8.6 Processing

    Science.gov (United States)

    McPeters, Richard; Bhartia, P. K.; Flynn, L.

    2012-01-01

    Under a NASA program to produce long term data records from instruments on multiple satellites (MEaSUREs), data from a series of eight SBUV and SBUV 12 instruments have been reprocessed to create a 40 year long ozone time series. Data from the Nimbus 4 BUV, Nimbus 7 SBUV, and SBUV/2 instruments on NOAA 9, 11, 14, 16, 17, and 18 were used covering the period 1970 to 1972 and 1979 to the present. In past analyses an ozone time series was created from these instruments by adjusting ozone itself, instrument by instrument, for consistency during overlap periods. In the version 8.6 processing adjustments were made to the radiance calibration of each instrument to maintain a consistent calibration over the entire time series. Data for all eight instruments were then reprocessed using the adjusted radiances. Reprocessing is necessary to produce an accurate latitude dependence. Other improvements incorporated in version 8.6 included the use of the ozone cross sections of Brion, Daumont, and Malicet, and the use of a cloud height climatology derived from Aura OMI measurements. The new cross sections have a more accurate temperature dependence than the cross sections previously used. The OMI-based cloud heights account for the penetration of UV into the upper layers of clouds. The consistency of the version 8.6 time series was evaluated by intra-instrument comparisons during overlap periods, comparisons with ground-based instruments, and comparisons with measurements made by instruments on other satellites such as SAGE II and UARS MLS. These comparisons show that for the instruments on NOAA 16, 17 and 18, the instrument calibrations were remarkably stable and consistent from instrument to instrument. The data record from the Nimbus 7 SBUV was also very stable, and SAGE and ground-based comparisons show that the' calibration was consistent with measurements made years laterby the NOAA 16 instrument. The calibrations of the SBUV/2 instruments on NOAA 9, 11, and 14 were more of

  4. Pengaruh Penambahan HHO Terhadap Kinerja Dan Ionisasi Pembakaran Motor Bensin

    OpenAIRE

    Akbar, Ali; Wardana, ING; Yuliati, Lilis

    2014-01-01

    This aim of this research was to conduct the effect of HHO which injected into the combustion chamber through the intake manifold of the gasoline four-stroke motorcycle engine. HHO is a mixture of hydrogen and oxygen was produced by water electrolysis process.The experiments were carried out by using the HHO generatorin intake manifold to produced HHO gas, which injected into the combustion chamber. The HHO gas injection was varied of 0 ml/s, 0.75 ml/s, 1.5 ml/s, 2.25 ml/s and 3 ml/s based on...

  5. User-assisted Object Detection by Segment Based Similarity Measures in Mobile Laser Scanner Data

    NARCIS (Netherlands)

    Oude Elberink, S.J.; Kemboi, B.J.

    2014-01-01

    This paper describes a method that aims to find all instances of a certain object in Mobile Laser Scanner (MLS) data. In a userassisted approach, a sample segment of an object is selected, and all similar objects are to be found. By selecting samples from multiple classes, a classification can be

  6. Should measurement of maximum urinary flow rate and residual urine volume be a part of a "minimal care" assessment programme in female incontinence?

    DEFF Research Database (Denmark)

    Sander, Pia; Mouritsen, L; Andersen, J Thorup

    2002-01-01

    OBJECTIVE: The aim of this study was to evaluate the value of routine measurements of urinary flow rate and residual urine volume as a part of a "minimal care" assessment programme for women with urinary incontinence in detecting clinical significant bladder emptying problems. MATERIAL AND METHODS....... Twenty-six per cent had a maximum flow rate less than 15 ml/s, but only 4% at a voided volume > or =200 ml. Residual urine more than 149 ml was found in 6%. Two women had chronic retention with overflow incontinence. Both had typical symptoms with continuous leakage, stranguria and chronic cystitis...

  7. Operationalising resilience to drought: Multi-layered safety for flooding applied to droughts

    Science.gov (United States)

    Rijke, Jeroen; Smith, Jennifer Vessels; Gersonius, Berry; van Herk, Sebastiaan; Pathirana, Assela; Ashley, Richard; Wong, Tony; Zevenbergen, Chris

    2014-11-01

    This paper sets out a way of thinking about how to prepare for and respond to droughts in a holistic way using a framework developed for managing floods. It shows how the multi-layered safety (MLS) approach for flood resilience can be utilised in the context of drought in a way that three layers of intervention can be distinguished for operationalising drought resilience: (1) protection against water shortage through augmentation and diversification of water supplies; (2) prevention of damage in case of water shortage through increased efficiency of water use and timely asset maintenance; (3) preparedness for future water shortages through mechanisms to reduce the use of water and adopt innovative water technologies. Application of MLS to the cities of Adelaide, Melbourne and Sydney shows that recent water reforms in these cities were primarily focused on protection measures that aim to reduce the hazard source or exposure to insufficient water supplies. Prevention and preparedness measures could be considered in defining interventions that aim to further increase the drought resilience of these cities. Although further research is needed, the application suggests that MLS can be applied to the context of drought risk management. The MLS framework can be used to classify the suite of plans deployed by a city to manage future drought risks and can be considered a planning tool to identify opportunities for increasing the level of redundancy and hence resilience of the drought risk management system.

  8. Workshop on the Suborbital Science Sounding Rocket Program, Volume 1

    Science.gov (United States)

    1991-01-01

    The unique characteristics of the sounding rocket program is described, with its importance to space science stressed, especially in providing UARS correlative measurements. The program provided opportunities to do innovative scientific studies in regions not other wise accessible; it was a testbed for developing new technologies; and its key attributes were flexibility, reliability, and economy. The proceedings of the workshop are presented in viewgraph form, including the objectives of the workshop and the workshop agenda.

  9. Differentiating between adductor and abductor spasmodic dysphonia using airflow interruption

    Science.gov (United States)

    Hoffman, Matthew R.; Jiang, Jack J.; Rieves, Adam L.; McElveen, Kelsey A.B.; Ford, Charles N.

    2009-01-01

    Objective To measure the laryngeal resistance (RL), subglottal pressure (Ps), and mean flow rate (MFR) of adductor (ADSD) and abductor (ABSD) spasmodic dysphonia patients using the airflow interrupter. Methods The RL of six ABSD and seven ADSD patients was measured using the airflow interrupter, a noninvasive device designed to measure MFR and Ps via mechanical balloon valve interruption. Subjects performed ten trials at each of two intensity levels, with each trial consisting of a sustained /a/ during which phonation was interrupted for 500 ms. Laryngeal resistance was calculated as subglottal pressure divided by airflow. Results Mean RL for the ADSD and ABSD subtypes at 65 dB were 24.78 cmH2O/l/s and 14.51 cmH2O/l/s, respectively (p = 0.04). Mean RL at 70 dB were 40.02 cmH2O/l/s and 15.84 cmH2O/l/s (p = 0.014). Ps for the ADSD and ABSD subtypes at 65 dB were 10.23 cmH2O and 8.32 cmH2O, respectively (p = 0.582). At the 70 dB level, Ps were 12.39 cmH2O and 11.78 cmH2O (p = 0.886). MFR for the ADSD and ABSD subtypes at 65 dB were 435 ml/s and 746 ml/s (p = 0.205). Mean MFR at 70 dB were 518 ml/s and 848 ml/s (p = 0.198). Conclusion Noninvasive measurements of RL may be useful for differentiating between ADSD and ABSD. This simple objective test which produces a quantitative output could be used to evaluate laryngeal function in patients with spasmodic dysphonia. PMID:19554636

  10. Diurnal variation of stratospheric and lower mesospheric HOCl, ClO and HO2 at the equator: comparison of 1-D model calculations with measurements by satellite instruments

    Directory of Open Access Journals (Sweden)

    M. Khosravi

    2013-08-01

    Full Text Available The diurnal variation of HOCl and the related species ClO, HO2 and HCl measured by satellites has been compared with the results of a one-dimensional photochemical model. The study compares the data from various limb-viewing instruments with model simulations from the middle stratosphere to the lower mesosphere. Data from three sub-millimetre instruments and two infrared spectrometers are used, namely from the Sub-Millimetre Radiometer (SMR on board Odin, the Microwave Limb Sounder (MLS on board Aura, the Superconducting Submillimeter-wave Limb-Emission Sounder (SMILES on the International Space Station, the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS on board ENVISAT, and the Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS on board SCISAT. Inter-comparison of the measurements from instruments on sun-synchronous satellites (SMR, MLS, MIPAS and measurements from solar occultation instruments (ACE-FTS is challenging since the measurements correspond to different solar zenith angles (or local times. However, using a model which covers all solar zenith angles and data from the SMILES instrument which measured at all local times over a period of several months provides the possibility to verify the model and to indirectly compare the diurnally variable species. The satellite data were averaged for latitudes of 20° S to 20° N for the SMILES observation period from November 2009 to April 2010 and were compared at three altitudes: 35, 45 and 55 km. Besides presenting the SMILES data, the study also shows a first comparison of the latest MLS data (version 3.3 of HOCl, ClO, and HO2 with other satellite observations, as well as a first evaluation of HO2 observations made by Odin/SMR. The MISU-1D model has been carefully initialised and run for conditions and locations of the observations. The diurnal cycle features for the species investigated here are generally well reproduced by the model. The satellite

  11. Evaluation of ozone profile and tropospheric ozone retrievals from GEMS and OMI spectra

    Directory of Open Access Journals (Sweden)

    J. Bak

    2013-02-01

    Full Text Available South Korea is planning to launch the GEMS (Geostationary Environment Monitoring Spectrometer instrument into the GeoKOMPSAT (Geostationary Korea Multi-Purpose SATellite platform in 2018 to monitor tropospheric air pollutants on an hourly basis over East Asia. GEMS will measure backscattered UV radiances covering the 300–500 nm wavelength range with a spectral resolution of 0.6 nm. The main objective of this study is to evaluate ozone profiles and stratospheric column ozone amounts retrieved from simulated GEMS measurements. Ozone Monitoring Instrument (OMI Level 1B radiances, which have the spectral range 270–500 nm at spectral resolution of 0.42–0.63 nm, are used to simulate the GEMS radiances. An optimal estimation-based ozone profile algorithm is used to retrieve ozone profiles from simulated GEMS radiances. Firstly, we compare the retrieval characteristics (including averaging kernels, degrees of freedom for signal, and retrieval error derived from the 270–330 nm (OMI and 300–330 nm (GEMS wavelength ranges. This comparison shows that the effect of not using measurements below 300 nm on retrieval characteristics in the troposphere is insignificant. However, the stratospheric ozone information in terms of DFS decreases greatly from OMI to GEMS, by a factor of ∼2. The number of the independent pieces of information available from GEMS measurements is estimated to 3 on average in the stratosphere, with associated retrieval errors of ~1% in stratospheric column ozone. The difference between OMI and GEMS retrieval characteristics is apparent for retrieving ozone layers above ~20 km, with a reduction in the sensitivity and an increase in the retrieval errors for GEMS. We further investigate whether GEMS can resolve the stratospheric ozone variation observed from high vertical resolution Earth Observing System (EOS Microwave Limb Sounder (MLS. The differences in stratospheric ozone profiles between GEMS and MLS are comparable to those

  12. Intracapillary HbO2 saturations in murine tumours and human tumour xenografts measured by cryospectrophotometry: relationship to tumour volume, tumour pH and fraction of radiobiologically hypoxic cells.

    Science.gov (United States)

    Rofstad, E K; Fenton, B M; Sutherland, R M

    1988-05-01

    Frequency distributions for intracapillary HbO2 saturation were determined for two murine tumour lines (KHT, RIF-1) and two human ovarian carcinoma xenograft lines (MLS, OWI) using a cryospectrophotometric method. The aim was to search for possible relationships between HbO2 saturation status and tumour volume, tumour pH and fraction of radiobiologically hypoxic cells. Tumour pH was measured by 31P NMR spectroscopy. Hypoxic fractions were determined from cell survival curves for tumours irradiated in vivo and assayed in vitro. Tumours in the volume range 100-4000 mm3 were studied and the majority of the vessels were found to have HbO2 saturations below 10%. The volume-dependence of the HbO2 frequency distributions differed significantly among the four tumour lines; HbO2 saturation status decreased with increasing tumour volume for the KHT, RIF-1 and MLS lines and was independent of tumour volume for the OWI line. The data indicated that the rate of decrease in HbO2 saturation status during tumour growth was related to the rate of development of necrosis. The volume-dependence of tumour pH was very similar to that of the HbO2 saturation status for all tumour lines. Significant correlations were therefore found between HbO2 saturation status and tumour pH, both within tumour lines and across the four tumour lines, reflecting that the volume-dependence of both parameters probably was a compulsory consequence of reduced oxygen supply conditions during tumour growth. Hypoxic fraction increased during tumour growth for the KHT, RIF-1 and MLS lines and was volume-independent for the OWI line, suggesting a relationship between HbO2 saturation status and hypoxic fraction within tumour lines. However, there was no correlation between these two parameters across the four tumour lines, indicating that the hypoxic fraction of a tumour is not determined only by the oxygen supply conditions; other parameters may also be important, e.g. oxygen diffusivity, rate of oxygen

  13. A Network Version of the Pump

    National Research Council Canada - National Science Library

    Kang, Myong H; Moskowitz, Ira S; Lee, Daniel C

    1995-01-01

    A designer of reliable MLS networks must consider covert channels and denial of service attacks in addition to traditional network performance measures such as throughput, fairness, and reliability...

  14. Comparison of circular orbit and Fourier power series ephemeris representations for backup use by the upper atmosphere research satellite onboard computer

    Science.gov (United States)

    Kast, J. R.

    1988-01-01

    The Upper Atmosphere Research Satellite (UARS) is a three-axis stabilized Earth-pointing spacecraft in a low-Earth orbit. The UARS onboard computer (OBC) uses a Fourier Power Series (FPS) ephemeris representation that includes 42 position and 42 velocity coefficients per axis, with position residuals at 10-minute intervals. New coefficients and 32 hours of residuals are uploaded daily. This study evaluated two backup methods that permit the OBC to compute an approximate spacecraft ephemeris in the event that new ephemeris data cannot be uplinked for several days: (1) extending the use of the FPS coefficients previously uplinked, and (2) switching to a simple circular orbit approximation designed and tested (but not implemented) for LANDSAT-D. The FPS method provides greater accuracy during the backup period and does not require additional ground operational procedures for generating and uplinking an additional ephemeris table. The tradeoff is that the high accuracy of the FPS will be degraded slightly by adopting the longer fit period necessary to obtain backup accuracy for an extended period of time. The results for UARS show that extended use of the FPS is superior to the circular orbit approximation for short-term ephemeris backup.

  15. Spiral CT portography: correlation with different injection rate

    International Nuclear Information System (INIS)

    Wu Dong; Zhou Kangrong; Chen Zuwang; Chen Gang; Chen Jin; Chen Huiming

    2000-01-01

    Objective: To choose optimal injection rate in spiral CT portography(CTP) by comparing 3D CTP images using different injection rates. Methods: Thirty-seven patients were randomly divided into 2 groups (11 and 26 cases in each group). Single-level dynamic scan was completed at the first liver hilus, starting at 15s or 30s after initial contrast injection(2 ml/kg) with injection rate 1.5 ml/s (slow group) or 3.0 ml/s (rapid group). The continuous scan were repeated every 5s for 120s or 135s. ROI was used to measure the CT value of the portal vein and the liver parenchyma, respectively, and then the time-density curves were drawn. Spiral CT portography were performed at injection rate of 1.5 ml/s or 3.0 ml/s as the delay time designed described above, including 98 cases in rapid group and 12 cases in slow group. Both MPVR (multi-projection volume reconstruction) and MIP (maximum intensity projection) were employed for reconstruction. All images were ranked according to the grade of portal vein, the different CT value between the portal vein and the liver parenchyma, the edge's definition of blood vessel, the grade of hepatic vein and the display of IVC by 2 radiologists. Results: The maximum density difference in average between the portal vein and the liver parenchyma was 53.4 HU and 83.9 HU, respectively (t = 16.418, P < 0.001) in slow group and rapid one, and the mean reaching time was 80s and 60s, respectively (t = 13.394, P < 0.001). In slow injection group, the average score of MPVR image was 9.3, while it was 12.5 (t = 3.514, P < 0.01) in rapid injection group. Rapid group was better than slow one at the PV-L, the grade of the portal vein, and the edge's definition of blood vessel. Conclusion: Using rapid injection rate (3.0 ml/s), the maximum density difference between the portal vein and the liver parenchyma increases, and the mean reaching time shortens. The quality of 3D CTP image of rapid injection rate (3.0 ml/s) is superior to that of slow injection rate

  16. An Autonomous Ultra-Wide Band-Based Attitude and Position Determination Technique for Indoor Mobile Laser Scanning

    Directory of Open Access Journals (Sweden)

    Lawrence Lau

    2018-04-01

    Full Text Available Mobile laser scanning (MLS has been widely used in three-dimensional (3D city modelling data collection, such as Google cars for Google Map/Earth. Building Information Modelling (BIM has recently emerged and become prominent. 3D models of buildings are essential for BIM. Static laser scanning is usually used to generate 3D models for BIM, but this method is inefficient if a building is very large, or it has many turns and narrow corridors. This paper proposes using MLS for BIM 3D data collection. The positions and attitudes of the mobile laser scanner are important for the correct georeferencing of the 3D models. This paper proposes using three high-precision ultra-wide band (UWB tags to determine the positions and attitudes of the mobile laser scanner. The accuracy of UWB-based MLS 3D models is assessed by comparing the coordinates of target points, as measured by static laser scanning and a total station survey.

  17. Structural, magnetic and magneto-transport properties of thermally evaporated Fe/Cu multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Bouziane, K.; Al-Busaidi, M.; Gismelseed, A.; Al-Rawas, A. [Physics Department, College of Science, Sultan Qabos University, P. O. Box 36, Postal Code 123, Al-Khodh, Muscat (Oman)

    2004-05-01

    Structural, magnetic and magneto-transport properties of thermally evaporated Fe/Cu multilayers (MLs) have been investigated. Although multilayered structure has been successfully obtained, a substantial interfacial roughness ranging from 0.6 nm to 1.2 nm has been determined. All Fe/Cu MLs were polycrystalline with an average grain size of about 10 nm. Fe was bcc and textured (110) whereas Cu was fcc(111). Transmission electron microscopy analysis showed that the fcc Cu layer was rather textured (110) and (100) at least in the first stage of growth of the Fe/Cu MLs. Conversion electron Moessbauer (CEMS) measurements indicated the existence of three phases. Two of them were magnetic with a dominant bcc Fe phase, followed by fcc Fe phase. The third phase was superparamagnetic. The CEMS results were explained in terms of the partial diffusion of Fe into Cu with three different zones. The small magnetoresistance (MR<0.2%) was correlated to Fe clusters located at Fe-Cu interfaces. (Abstract Copyright [2004], Wiley Periodicals, Inc.)

  18. The effect of sleep onset on upper airway muscle activity in patients with sleep apnoea versus controls

    Science.gov (United States)

    Fogel, Robert B; Trinder, John; White, David P; Malhotra, Atul; Raneri, Jill; Schory, Karen; Kleverlaan, Darci; Pierce, Robert J

    2005-01-01

    Pharyngeal dilator muscles are important in the pathophysiology of obstructive sleep apnoea syndrome (OSA). We have previously shown that during wakefulness, the activity of both the genioglossus (GGEMG) and tensor palatini (TPEMG) is greater in patients with OSA compared with controls. Further, EMG activity decreases at sleep onset, and the decrement is greater in apnoea patients than in healthy controls. In addition, it is known that the prevalence of OSA is greater in middle-aged compared with younger men. Thus, we had two goals in this study. First we compared upper airway muscle activity between young and middle-aged healthy men compared with men with OSA. We also explored the mechanisms responsible for the decrement in muscle activity at sleep onset in these groups. We investigated muscle activity, ventilation , and upper airway resistance (UAR) during wakefulness and sleep onset (transition from α to θ EEG activity) in all three groups. Measurements were obtained during basal breathing (BB) and nasal continuous positive airway pressure (CPAP) was applied to reduce negative pressure-mediated muscle activation). We found that during wakefulness there was a gradation of GGEMG and UAR (younger < older < OSA) and that muscle activity was reduced by the application of nasal CPAP (to a greater degree in the OSA patients). Although CPAP eliminated differences in UAR during wakefulness and sleep, GGEMG remained greater in the OSA patients. During sleep onset, a greater initial fall in GGEMG was seen in the OSA patients followed by subsequent muscle recruitment in the third to fifth breaths following the α to θ transition. On the CPAP night, and GGEMG still fell further in the OSA patients compared with control subjects. CPAP prevented the rise in UAR at sleep onset along with the associated recruitment in GGEMG. Differences in TPEMG among the groups were not significant. These data suggest that the middle-aged men had upper airway function midway between that of

  19. Brief communication "Application of mobile laser scanning in snow cover profiling"

    Directory of Open Access Journals (Sweden)

    S. Kaasalainen

    2011-03-01

    Full Text Available We present a snowmobile-based mobile mapping system and its first application to snow cover roughness and change detection measurement. The ROAMER mobile mapping system, constructed at the Finnish Geodetic Institute, consists of the positioning and navigating systems, a terrestrial laser scanner, and the carrying platform (a snowmobile sledge in this application. We demonstrate the applicability of the instrument to snow cover roughness profiling and change detection by presenting preliminary results from a mobile laser scanning (MLS campaign. The results show the potential of MLS for fast and efficient snow profiling from large areas in a millimetre scale.

  20. Journal of Earth System Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    It is examined whether high resolution radiosonde measurements represent well the UTWV by comparing with different satellite based (Atmospheric Infrared Sounder (AIRS), Advanced Microwave Sounding Unit-B (AMSUB) and Microwave Limb Sounder (MLS)) water vapour measurements. Very good comparison in the ...

  1. VESPA-22: a ground-based microwave spectrometer for long-term measurements of polar stratospheric water vapor

    Science.gov (United States)

    Mevi, Gabriele; Muscari, Giovanni; Bertagnolio, Pietro Paolo; Fiorucci, Irene; Pace, Giandomenico

    2018-02-01

    The new ground-based 22 GHz spectrometer, VESPA-22 (water Vapor Emission Spectrometer for Polar Atmosphere at 22 GHz) measures the 22.23 GHz water vapor emission line with a bandwidth of 500 MHz and a frequency resolution of 31 kHz. The integration time for a measurement ranges from 6 to 24 h, depending on season and weather conditions. Water vapor spectra are collected using the beam-switching technique. VESPA-22 is designed to operate automatically with little maintenance; it employs an uncooled front-end characterized by a receiver temperature of about 180 K and its quasi-optical system presents a full width at half maximum of 3.5°. Every 30 min VESPA-22 measures also the sky opacity using the tipping curve technique. The instrument calibration is performed automatically by a noise diode; the emission temperature of this element is estimated twice an hour by observing alternatively a black body at ambient temperature and the sky at an elevation of 60°. The retrieved profiles obtained inverting 24 h integration spectra present a sensitivity larger than 0.8 from about 25 to 75 km of altitude during winter and from about 30 to 65 km during summer, a vertical resolution from about 12 to 23 km (depending on altitude), and an overall 1σ uncertainty lower than 7 % up to 60 km altitude and rapidly increasing to 20 % at 75 km. In July 2016, VESPA-22 was installed at the Thule High Arctic Atmospheric Observatory located at Thule Air Base (76.5° N, 68.8° W), Greenland, and it has been operating almost continuously since then. The VESPA-22 water vapor mixing ratio vertical profiles discussed in this work are obtained from 24 h averaged spectra and are compared with version 4.2 of concurrent Aura/Microwave Limb Sounder (MLS) water vapor vertical profiles. In the sensitivity range of VESPA-22 retrievals, the intercomparison from July 2016 to July 2017 between VESPA-22 dataset and Aura/MLS dataset convolved with VESPA-22 averaging kernels shows an average difference

  2. Global distributions of diurnal and semidiurnal tides: observations from HRDI-UARS of the MLT region and comparisons with GSWM-02 (migrating, nonmigrating components

    Directory of Open Access Journals (Sweden)

    A. H. Manson

    2004-04-01

    Full Text Available HRDI (High Resolution Doppler Interferometer-UARS winds data have been analyzed in 4°-latitude by 10°-longitude cells at 96km to obtain the global distribution of the solar-tidal amplitudes and phases. The solstices June–July (1993, December–January (1993–1994, and one equinox (September–October, 1994 are analyzed. In an earlier paper (Manson et al., 2002b the emphasis was solely upon the longitudinal and latitudinal variations of the amplitudes and phases of the semidiurnal (12h and diurnal (24h tides. The longitudinal structures were shown to be quite distinctive, and in the case of the EW component of the diurnal tide there were typically four maxima/perturbations of amplitudes or phases around a latitude circle. In this case they tended to be associated with the locations of the major oceans. Here, a spatial complex spectral analysis has been applied to the data set, to obtain the zonal wave numbers for the tides as functions of latitude. For the diurnal tide the dominant s=1 migrating component and nonmigrating tides with wave numbers s=–3, –2, 0, 2 are identified; and for the semidiurnal tide, as well as the dominant s=2 migrating component, the spectra indicate the presence of nonmigrating tides with wave numbers s=–2, 0, 4. These wave numbers are also simply related to the global longitudinal structures in the tidal amplitudes and phases. Comparisons are made with the Global Scale Wave Model (GSWM-02, which now incorporates migrating and nonmigrating tides associated with tropospheric latent heat processes, and offers monthly outputs. For the diurnal tide the dominant nonmigrating tidal spectral feature (94km is for wave number s=–3; it is relatively stronger than in the HRDI winds, and produces quite consistent structures in the global tidal fields with four longitudinal maxima. Overall, the modelled 24-h tidal amplitudes are larger than observed during the equinox beyond 40° latitude. For the semidiurnal tide

  3. The effect of moisture on the shear bond strength of gold alloy rods bonded to enamel with a self-adhesive and a hydrophobic resin cement.

    Science.gov (United States)

    Dursun, Elisabeth; Wiechmann, Dirk; Attal, Jean-Pierre

    2010-06-01

    The aim of this in vitro study was to investigate the influence of enamel moisture on the shear bond strength (SBS) of a hydrophobic resin cement, Maximum Cure (MC), and a self-adhesive resin cement, Multilink Sprint (MLS), after etching of the enamel. Forty cylindrical gold alloy rods were used to simulate the Incognito lingual bracket system. They were bonded to the enamel of 40 human teeth embedded in self-cured acrylic resin. Twenty were bonded with MC (10 on dry and 10 on wet enamel) and 20 with MLS (10 on dry and 10 on wet enamel). The SBS of MC and MLS was determined in a universal testing machine and the site of bond failure was defined by the adhesive remnant index (ARI). A Kruskal-Wallis test was performed followed by Games-Howell post hoc pairwise comparison tests on the SBS results (P enamel, no significant differences between MC (58 +/- 5 MPa) and MLS (64 +/- 13 MPa) were noted. On wet enamel, the adherence of MC (6 +/- 8 MPa) and MLS (37 +/- 13 MPa) significantly decreased but to a lesser extent for MLS. The ARI scores corroborated these results. In conclusion, MC did not tolerate moisture. MLS was also affected but maintained sufficient adherence.

  4. Validation of ozone profile retrievals derived from the OMPS LP version 2.5 algorithm against correlative satellite measurements

    Science.gov (United States)

    Kramarova, Natalya A.; Bhartia, Pawan K.; Jaross, Glen; Moy, Leslie; Xu, Philippe; Chen, Zhong; DeLand, Matthew; Froidevaux, Lucien; Livesey, Nathaniel; Degenstein, Douglas; Bourassa, Adam; Walker, Kaley A.; Sheese, Patrick

    2018-05-01

    The Limb Profiler (LP) is a part of the Ozone Mapping and Profiler Suite launched on board of the Suomi NPP satellite in October 2011. The LP measures solar radiation scattered from the atmospheric limb in ultraviolet and visible spectral ranges between the surface and 80 km. These measurements of scattered solar radiances allow for the retrieval of ozone profiles from cloud tops up to 55 km. The LP started operational observations in April 2012. In this study we evaluate more than 5.5 years of ozone profile measurements from the OMPS LP processed with the new NASA GSFC version 2.5 retrieval algorithm. We provide a brief description of the key changes that had been implemented in this new algorithm, including a pointing correction, new cloud height detection, explicit aerosol correction and a reduction of the number of wavelengths used in the retrievals. The OMPS LP ozone retrievals have been compared with independent satellite profile measurements obtained from the Aura Microwave Limb Sounder (MLS), Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS) and Odin Optical Spectrograph and InfraRed Imaging System (OSIRIS). We document observed biases and seasonal differences and evaluate the stability of the version 2.5 ozone record over 5.5 years. Our analysis indicates that the mean differences between LP and correlative measurements are well within required ±10 % between 18 and 42 km. In the upper stratosphere and lower mesosphere (> 43 km) LP tends to have a negative bias. We find larger biases in the lower stratosphere and upper troposphere, but LP ozone retrievals have significantly improved in version 2.5 compared to version 2 due to the implemented aerosol correction. In the northern high latitudes we observe larger biases between 20 and 32 km due to the remaining thermal sensitivity issue. Our analysis shows that LP ozone retrievals agree well with the correlative satellite observations in characterizing vertical, spatial and temporal

  5. Comparative evaluation of marginal fit and axial wall adaptability of copings fabricated by metal laser sintering and lost-wax technique: An in vitro study.

    Science.gov (United States)

    Gaikwad, Bhushan Satish; Nazirkar, Girish; Dable, Rajani; Singh, Shailendra

    2018-01-01

    The present study aims to compare and evaluate the marginal fit and axial wall adaptability of Co-Cr copings fabricated by metal laser sintering (MLS) and lost-wax (LW) techniques using a stereomicroscope. A stainless steel master die assembly was fabricated simulating a prepared crown; 40 replicas of master die were fabricated in gypsum type IV and randomly divided in two equal groups. Group A coping was fabrication by LW technique and the Group B coping fabrication by MLS technique. The copings were seated on their respective gypsum dies and marginal fit was measured using stereomicroscope and image analysis software. For evaluation of axial wall adaptability, the coping and die assembly were embedded in autopolymerizing acrylic resin and sectioned vertically. The discrepancies between the dies and copings were measured along the axial wall on each halves. The data were subjected to statistical analysis using unpaired t -test. The mean values of marginal fit for copings in Group B (MLS) were lower (24.6 μm) than the copings in Group A (LW) (39.53 μm), and the difference was statistically significant ( P adaptability in comparison with copings fabricated by the LW technique. However, the values of marginal fit of copings fabricated that the two techniques were within the clinically acceptable limit (<50 μm).

  6. A novel magnetic lead screw active suspension system for vehicles

    DEFF Research Database (Denmark)

    Berg, Nick Ilsø; Holm, Rasmus Koldborg; Rasmussen, Peter Omand

    2014-01-01

    This paper encompasses a detailed study of the redesign of a novel Magnetic Lead Screw (MLS) active suspension system for possible regeneration of the energy dispatched in the suspension system and active control of vehicle body movement. The MLS converts a low speed high force linear motion...... of a translator into a high speed low torque rotational motion of a rotor through helically shaped magnets. The paper describes the drawback of the first MLS prototype v1.0 developed for active suspension system, which lead to a new design of the MLS prototype named v1.5. Furthermore the paper introduces detailed...

  7. Platelet associated IgG, platelet mean life span and treatment with intravenous immunoglobulin in idiopathic thrombocytopenic purpura

    International Nuclear Information System (INIS)

    Nieminen, U.; Syrjaelae, M.; Ikkala, E.; Myllylae, G.

    1988-01-01

    The clinical significance of platelet associated IgG in ITP detected by direct platelet suspension immunofluorescence test (PSIFT) was studied. The platelet mean life span (MLS) was measured with 111 In-labelled platelets in 17 adult patients. All the patients had shortened platelet MLS. The direct PSIFT was positive in 14 patients. Patients were initially treated with prednisone; 12 patients with poor response to the drug were splenectomised. 8 of these 12 patients were treated with intravenous immunoglobulin (IvIg) before splenectomy. The response to IvIg was as good or better in the 3 patients with negative PSIFT, than in the 5 patients with positive PSIFT. (author)

  8. Comparison of Global Distributions of Zonal-Mean Gravity Wave Variance Inferred from Different Satellite Instruments

    Science.gov (United States)

    Preusse, Peter; Eckermann, Stephen D.; Offermann, Dirk; Jackman, Charles H. (Technical Monitor)

    2000-01-01

    Gravity wave temperature fluctuations acquired by the CRISTA instrument are compared to previous estimates of zonal-mean gravity wave temperature variance inferred from the LIMS, MLS and GPS/MET satellite instruments during northern winter. Careful attention is paid to the range of vertical wavelengths resolved by each instrument. Good agreement between CRISTA data and previously published results from LIMS, MLS and GPS/MET are found. Key latitudinal features in these variances are consistent with previous findings from ground-based measurements and some simple models. We conclude that all four satellite instruments provide reliable global data on zonal-mean gravity wave temperature fluctuations throughout the middle atmosphere.

  9. Validation of ozone profile retrievals derived from the OMPS LP version 2.5 algorithm against correlative satellite measurements

    Directory of Open Access Journals (Sweden)

    N. A. Kramarova

    2018-05-01

    Full Text Available The Limb Profiler (LP is a part of the Ozone Mapping and Profiler Suite launched on board of the Suomi NPP satellite in October 2011. The LP measures solar radiation scattered from the atmospheric limb in ultraviolet and visible spectral ranges between the surface and 80 km. These measurements of scattered solar radiances allow for the retrieval of ozone profiles from cloud tops up to 55 km. The LP started operational observations in April 2012. In this study we evaluate more than 5.5 years of ozone profile measurements from the OMPS LP processed with the new NASA GSFC version 2.5 retrieval algorithm. We provide a brief description of the key changes that had been implemented in this new algorithm, including a pointing correction, new cloud height detection, explicit aerosol correction and a reduction of the number of wavelengths used in the retrievals. The OMPS LP ozone retrievals have been compared with independent satellite profile measurements obtained from the Aura Microwave Limb Sounder (MLS, Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS and Odin Optical Spectrograph and InfraRed Imaging System (OSIRIS. We document observed biases and seasonal differences and evaluate the stability of the version 2.5 ozone record over 5.5 years. Our analysis indicates that the mean differences between LP and correlative measurements are well within required ±10 % between 18 and 42 km. In the upper stratosphere and lower mesosphere (> 43 km LP tends to have a negative bias. We find larger biases in the lower stratosphere and upper troposphere, but LP ozone retrievals have significantly improved in version 2.5 compared to version 2 due to the implemented aerosol correction. In the northern high latitudes we observe larger biases between 20 and 32 km due to the remaining thermal sensitivity issue. Our analysis shows that LP ozone retrievals agree well with the correlative satellite observations in characterizing

  10. Effect of a synesthete's photisms on name recall.

    Science.gov (United States)

    Mills, Carol Bergfeld; Innis, Joanne; Westendorf, Taryn; Owsianiecki, Lauren; McDonald, Angela

    2006-02-01

    A multilingual, colored-letter synesthete professor (MLS), 9 nonsynesthete multilingual professors and 4 nonsynesthete art professors learned 30 names of individuals (first and last name pairs) in three trials. They recalled the names after each trial and six months later, as well as performed cued recall trials initially and after six months. As hypothesized, MLS recalled significantly more names than control groups on all free recall tests (except after the first trial) and on cued recall tests. In addition, MLS gave qualitatively different reasons for remembering names than any individual control participant. MLS gave mostly color reasons for remembering the names, whereas nonsynesthetes gave reasons based on familiarity or language or art knowledge. Results on standardized memory tests showed that MLS had average performance on non-language visual memory tests (the Benton Visual Retention Test-Revised--BURT-R, and the Rey-Osterrieth Complex Figure Test--CFT), but had superior memory performance on a verbal test consisting of lists of nouns (Rey Auditory-Verbal Learning Test--RAVLT). MLS's synesthesia seems to aid memory for visually or auditorily presented language stimuli (names and nouns), but not for non-language visual stimuli (simple and complex figures).

  11. Global distributions of diurnal and semidiurnal tides: observations from HRDI-UARS of the MLT region and comparisons with GSWM-02 (migrating, nonmigrating components

    Directory of Open Access Journals (Sweden)

    A. H. Manson

    2004-04-01

    Full Text Available HRDI (High Resolution Doppler Interferometer-UARS winds data have been analyzed in 4°-latitude by 10°-longitude cells at 96km to obtain the global distribution of the solar-tidal amplitudes and phases. The solstices June–July (1993, December–January (1993–1994, and one equinox (September–October, 1994 are analyzed.

    In an earlier paper (Manson et al., 2002b the emphasis was solely upon the longitudinal and latitudinal variations of the amplitudes and phases of the semidiurnal (12h and diurnal (24h tides. The longitudinal structures were shown to be quite distinctive, and in the case of the EW component of the diurnal tide there were typically four maxima/perturbations of amplitudes or phases around a latitude circle. In this case they tended to be associated with the locations of the major oceans. Here, a spatial complex spectral analysis has been applied to the data set, to obtain the zonal wave numbers for the tides as functions of latitude. For the diurnal tide the dominant s=1 migrating component and nonmigrating tides with wave numbers s=–3, –2, 0, 2 are identified; and for the semidiurnal tide, as well as the dominant s=2 migrating component, the spectra indicate the presence of nonmigrating tides with wave numbers s=–2, 0, 4. These wave numbers are also simply related to the global longitudinal structures in the tidal amplitudes and phases.

    Comparisons are made with the Global Scale Wave Model (GSWM-02, which now incorporates migrating and nonmigrating tides associated with tropospheric latent heat processes, and offers monthly outputs. For the diurnal tide the dominant nonmigrating tidal spectral feature (94km is for wave number s=–3; it is relatively stronger than in the HRDI winds, and produces quite consistent structures in the global tidal fields with four longitudinal maxima. Overall, the modelled 24-h tidal amplitudes are larger than observed

  12. Bias Correction and Random Error Characterization for the Assimilation of HRDI Line-of-Sight Wind Measurements

    Science.gov (United States)

    Tangborn, Andrew; Menard, Richard; Ortland, David; Einaudi, Franco (Technical Monitor)

    2001-01-01

    A new approach to the analysis of systematic and random observation errors is presented in which the error statistics are obtained using forecast data rather than observations from a different instrument type. The analysis is carried out at an intermediate retrieval level, instead of the more typical state variable space. This method is carried out on measurements made by the High Resolution Doppler Imager (HRDI) on board the Upper Atmosphere Research Satellite (UARS). HRDI, a limb sounder, is the only satellite instrument measuring winds in the stratosphere, and the only instrument of any kind making global wind measurements in the upper atmosphere. HRDI measures doppler shifts in the two different O2 absorption bands (alpha and B) and the retrieved products are tangent point Line-of-Sight wind component (level 2 retrieval) and UV winds (level 3 retrieval). This analysis is carried out on a level 1.9 retrieval, in which the contributions from different points along the line-of-sight have not been removed. Biases are calculated from O-F (observed minus forecast) LOS wind components and are separated into a measurement parameter space consisting of 16 different values. The bias dependence on these parameters (plus an altitude dependence) is used to create a bias correction scheme carried out on the level 1.9 retrieval. The random error component is analyzed by separating the gamma and B band observations and locating observation pairs where both bands are very nearly looking at the same location at the same time. It is shown that the two observation streams are uncorrelated and that this allows the forecast error variance to be estimated. The bias correction is found to cut the effective observation error variance in half.

  13. Importance of clinical microbiologists for U.S. healthcare infrastructure.

    Science.gov (United States)

    Carvalho, John

    2011-01-01

    Clinical microbiologists are highly skilled scientists within national hospitals and reference laboratories who diagnose patients with infections by emerging pathogens. Most advanced training for clinical microbiologists occurs at universities, where an individual can receive certification as a "Medical Laboratory Scientist" (MLS). Unfortunately, many MLS programs have closed in the United States and this has caused a shortage of clinical microbiologists at U.S. hospitals and reference laboratories. This paper explores the present crisis in MLS training and its ramifications for the emergence of antibiotic-resistant bacteria, the economics of hospitals, and the overall health of the nation, and provides resolutions for better public health policy with respect to MLS education.

  14. Upper airway resistance syndrome. Central electroencephalographic power and changes in breathing effort.

    Science.gov (United States)

    Black, J E; Guilleminault, C; Colrain, I M; Carrillo, O

    2000-08-01

    Upper airway resistance syndrome (UARS) is defined by excessive daytime sleepiness and tiredness, and is associated with increased breathing effort. Its polygraphic features involve progressive increases in esophageal pressure (Pes), terminated by arousal (AR) as defined by the American Sleep Disorders Association (ASDA). With the arousal there is an abrupt decrease in Pes, called Pes reversal. However, Pes reversal can be seen without the presence of an AR. We performed spectral analysis on electroencephalographic data from a central lead for both AR and nonarousal (N-AR) events obtained from 15 UARS patients (eight men and seven women). Delta band activity was increased before and surrounding Pes reversal regardless of the presence or absence of AR. In the period after Pes reversal, alpha, sigma, and beta activity showed a greater increase in AR events than in N-AR events. The Pes measures were identical leading up to the point of reversal, but showed a longer-lasting and significantly greater decrease in respiratory effort after an AR. The data indicate that substantial electroencephalographic changes can be identified in association with Pes events, even when ARs cannot be detected according to standard criteria; however, visually identifiable electroencephalographic arousals clearly have a greater impact on ongoing inspiratory effort.

  15. Investigations on structural and multiferroic properties of artificially engineered lead zirconate titanate-cobalt iron oxide layered nanostructures

    Science.gov (United States)

    Ortega Achury, Nora Patricia

    Mutiferroics are a novel class of next generation multifunctional materials, which display simultaneous magnetic, electric, and ferroelastic ordering, have drawn increasing interest due to their multi-functionality for a variety of device applications. Since, very rare single phase materials exist in nature this kind of properties, an intensive research activity is being pursued towards the development of new engineered materials with strong magneto-electric (ME) coupling. In the present investigation, we have fabricated polycrystalline and highly oriented PbZr0.53,Ti0.47O3--CoFe 2O4 (PZT/CFO) artificially multilayers (MLs) engineered nanostructures thin films which were grown on Pt/TiO2/SiO2/Si and La 0.5Sr0.5CoO3 (LSCO) coated (001) MgO substrates respectively, using the pulsed laser deposition technique. The effect of various PZT/CFO sandwich configurations having 3, 5, and 9 layers, while maintaining similar total PZT and CFO thickness, has been systematically investigated. The first part of this thesis is devoted to the analysis of structural and microstructure properties of the PZT/CFO MLs. X-ray diffraction (XRD) and micro Raman analysis revealed that PZT and CFO were in the perovskite and spinel phases respectively in the all layered nanostructure, without any intermediate phase. The TEM and STEM line scan of the ML thin films showed that the layered structure was maintained with little inter-diffusion near the interfaces at nano-metric scale without any impurity phase, however better interface was observed in highly oriented films. Second part of this dissertation was dedicated to study of the dielectric, impedance, modulus, and conductivity spectroscopies. These measurements were carried out over a wide range of temperatures (100 K to 600 K) and frequencies (100 Hz to 1 MHz) to investigate the grain and grain boundary effects on electrical properties of MLs. The temperature dependent dielectric and loss tangent illustrated step-like behavior and

  16. Terminal area automatic navigation, guidance and control research using the Microwave Landing System (MLS). Part 5: Design and development of a Digital Integrated Automatic Landing System (DIALS) for steep final approach using modern control techniques

    Science.gov (United States)

    Halyo, N.

    1983-01-01

    The design and development of a 3-D Digital Integrated Automatic Landing System (DIALS) for the Terminal Configured Vehicle (TCV) Research Aircraft, a B-737-100 is described. The system was designed using sampled data Linear Quadratic Gaussian (LOG) methods, resulting in a direct digital design with a modern control structure which consists of a Kalman filter followed by a control gain matrix, all operating at 10 Hz. DIALS uses Microwave Landing System (MLS) position, body-mounted accelerometers, as well as on-board sensors usually available on commercial aircraft, but does not use inertial platforms. The phases of the final approach considered are the localizer and glideslope capture which may be performed simultaneously, localizer and steep glideslope track or hold, crab/decrab and flare to touchdown. DIALS captures, tracks and flares from steep glideslopes ranging from 2.5 deg to 5.5 deg, selected prior to glideslope capture. Digital Integrated Automatic Landing System is the first modern control design automatic landing system successfully flight tested. The results of an initial nonlinear simulation are presented here.

  17. New Visual Prostate Symptom Score versus International Prostate ...

    African Journals Online (AJOL)

    Qavrg (average urine flow rate expressed in ml/s) were measured and correlated. ... question, evaluating a combination of urinary storage and voiding symptoms ... 0.05 and power required 90%, the sample size needed was. 96. Hence, a total ...

  18. Identification of an organic semiconductor superlattice structure of pentacene and perfluoro-pentacene through resonant and non-resonant X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Kowarik, S.; Weber, C. [Humboldt-Universität zu Berlin, Institut für Physik, Newtonstr. 15, 12489 Berlin (Germany); Hinderhofer, A.; Gerlach, A.; Schreiber, F. [Universität Tübingen, Institut für Angewandte Physik, Auf der Morgenstelle 10, 72076 Tübingen (Germany); Wang, C.; Hexemer, A. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Leone, S. R. [Departments of Chemistry and Physics, University of California, and Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2015-11-15

    Highly crystalline and stable molecular superlattices are grown with the smallest possible stacking period using monolayers (MLs) of the organic semiconductors pentacene (PEN) and perfluoro-pentacene (PFP). Superlattice reflections in X-ray reflectivity and their energy dependence in resonant soft X-ray reflectivity measurements show that PFP and PEN MLs indeed alternate even though the coherent ordering is lost after ∼ 4 ML. The observed lattice spacing of 15.9 Å in the superlattice is larger than in pure PEN and PFP films, presumably because of more upright standing molecules and lack of interdigitation between the incommensurate crystalline PEN and PFP layers. The findings are important for the development of novel organic quantum optoelectronic devices.

  19. Identification of an organic semiconductor superlattice structure of pentacene and perfluoro-pentacene through resonant and non-resonant X-ray scattering

    Directory of Open Access Journals (Sweden)

    S. Kowarik

    2015-11-01

    Full Text Available Highly crystalline and stable molecular superlattices are grown with the smallest possible stacking period using monolayers (MLs of the organic semiconductors pentacene (PEN and perfluoro-pentacene (PFP. Superlattice reflections in X-ray reflectivity and their energy dependence in resonant soft X-ray reflectivity measurements show that PFP and PEN MLs indeed alternate even though the coherent ordering is lost after ∼ 4 ML. The observed lattice spacing of 15.9 Å in the superlattice is larger than in pure PEN and PFP films, presumably because of more upright standing molecules and lack of interdigitation between the incommensurate crystalline PEN and PFP layers. The findings are important for the development of novel organic quantum optoelectronic devices.

  20. Low-dose chemotherapy of hepatocellular carcinoma through triggered-release from bilayer-decorated magnetoliposomes.

    Science.gov (United States)

    Chen, Yanjing; Chen, Yuan; Xiao, Da; Bose, Arijit; Deng, Ruitang; Bothun, Geoffrey D

    2014-04-01

    Low-dose (LD) chemotherapy is a promising treatment strategy that may be improved by controlled delivery. Polyethylene glycol-stabilized bilayer-decorated magnetoliposomes (dMLs) have been designed as a stimuli-responsive LD chemotherapy drug delivery system and tested in vitro using Huh-7 hepatocellular carcinoma cell line. The dMLs contained hydrophobic superparamagnetic iron oxide nanoparticles within the lipid bilayer and doxorubicin hydrochloride (DOX, 2 μM) within the aqueous core. Structural analysis by cryogenic transmission electron microscopy and dynamic light scattering showed that the assemblies were approximately 120 nm in diameter. Furthermore, the samples consisted of a mixture of dMLs and bare liposomes (no nanoparticles), which provided dual burst and spontaneous DOX release profiles, respectively. Cell viability results show that the cytotoxicity of DOX-loaded dMLs was similar to that of bare dMLs (∼10%), which indicates that spontaneous DOX leakage had little cytotoxic effect. However, when subjected to a physiologically acceptable radiofrequency (RF) electromagnetic field, cell viability was reduced up to 40% after 8h and significant cell death (>90%) was observed after 24h. The therapeutic mechanism was intracellular RF-triggered DOX release from the dMLs and not intracellular hyperthermia due to nanoparticle heating via magnetic losses. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Performance analysis of a compact and low-cost mapping-grade mobile laser scanning system

    Science.gov (United States)

    Julge, Kalev; Vajakas, Toivo; Ellmann, Artu

    2017-10-01

    The performance of a low-cost, self-contained, compact, and easy to deploy mapping-grade mobile laser scanning (MLS) system, which is composed of a light detection and ranging sensor Velodyne VLP-16 and a dual antenna global navigation satellite system/inertial navigation system SBG Systems Ellipse-D, is analyzed. The field tests were carried out in car-mounted and backpack modes for surveying road engineering structures (such as roads, parking lots, underpasses, and tunnels) and coastal erosion zones, respectively. The impact of applied calculation principles on trajectory postprocessing, direct georeferencing, and the theoretical accuracy of the system is analyzed. A calibration method, based on Bound Optimization BY Quadratic Approximation, for finding the boresight angles of an MLS system is proposed. The resulting MLS point clouds are compared with high-accuracy static terrestrial laser scanning data and survey-grade MLS data from a commercially manufactured MLS system. The vertical, horizontal, and relative accuracy are assessed-the root-mean-square error (RMSE) values were determined to be 8, 15, and 3 cm, respectively. Thus, the achieved mapping-grade accuracy demonstrates that this relatively compact and inexpensive self-assembled MLS can be successfully used for surveying the geometry and deformations of terrain, buildings, road, and other engineering structures.

  2. Antimicrobial Resistance of Staphylococcal Strains Isolated from Various Pathological Products

    Directory of Open Access Journals (Sweden)

    Laura-Mihaela SIMON

    2010-12-01

    Full Text Available Background: The optimal choice of antimicrobial therapy is an important problem in hospital environment in which the selection of resistant and virulent strains easy occurs. S. aureus and especially MRSA(methicillin-resistant S. aureus creates difficulties in both treatment and prevention of nosocomial infections. Aim: The purpose of this study is to determine the sensitivity and the resistance to chemotherapy of staphylococci strains isolated from various pathological products. Material and Method: We identified Staphylococccus species after morphological appearance, culture properties, the production of coagulase, hemolisines and the enzyme activity. The susceptibility tests were performed on Mueller-Hinton medium according to CLSI (Clinical and Laboratory Standards Institute. Results: The strains were: MSSA (methicillin-susceptible S. aureus (74%, MRSA (8%, MLS B (macrolides, lincosamides and type B streptogramines resistance (12% and MRSA and MLS B (6%. MRSA strains were more frequently isolated from sputum. MRSA associated with the MLS B strains were more frequently isolated from pus. MLS B strains were more frequently isolated from sputum and throat secretions. All S. aureus strains were susceptible to vancomycin and teicoplanin. Conclusions: All staphylococcal infections require resistance testing before treatment. MLS B shows a high prevalence among strains of S. aureus. The association between MLS B and MRSA remains a major problem in Romania.

  3. The Mission Operations Planning Assistant

    Science.gov (United States)

    Schuetzle, James G.

    1987-01-01

    The Mission Operations Planning Assistant (MOPA) is a knowledge-based system developed to support the planning and scheduling of instrument activities on the Upper Atmospheric Research Satellite (UARS). The MOPA system represents and maintains instrument plans at two levels of abstraction in order to keep plans comprehensible to both UARS Principal Investigators and Command Management personnel. The hierarchical representation of plans also allows MOPA to automatically create detailed instrument activity plans from which spacecraft command loads may be generated. The MOPA system was developed on a Symbolics 3640 computer using the ZetaLisp and ART languages. MOPA's features include a textual and graphical interface for plan inspection and modification, recognition of instrument operational constraint violations during the planning process, and consistency maintenance between the different planning levels. This paper describes the current MOPA system.

  4. Estructura genética y simulaciones de máxima verosimilitud y Estadística Bayesiana aplicada a la conservación genética del Oso andino (Tremarctos ornatus en Venezuela, Colombia, Ecuador y Bolivia

    Directory of Open Access Journals (Sweden)

    M. Ruiz-García

    2001-07-01

    Full Text Available Se analizaron 115 muestras de oso andino procedentes de Venezuela, Colombia, Ecuador yBolivia mediante 5 microsatélites (G1A, G1D, G10B, G10C, G10M, G10P, G10X, UarMu 50,UarMu, 59. Se detectó: (1 No existencia de equilibrio Hardy-Weinberg en ninguna de laspoblaciones analizadas en cada uno de los países, lo que evidencia la existencia de efectoWahlund. (2 Los niveles de variabilidad genética fueron bajos (H=0.40, población total.Alarmantemente bajo fue el nivel de heterocigocidad en la población de Ecuador (H=0.27. (3Los niveles de flujo génico resultaron bajísimos (Nm=0.2-0.3.

  5. VESPA-22: a ground-based microwave spectrometer for long-term measurements of polar stratospheric water vapor

    Directory of Open Access Journals (Sweden)

    G. Mevi

    2018-02-01

    Full Text Available The new ground-based 22 GHz spectrometer, VESPA-22 (water Vapor Emission Spectrometer for Polar Atmosphere at 22 GHz measures the 22.23 GHz water vapor emission line with a bandwidth of 500 MHz and a frequency resolution of 31 kHz. The integration time for a measurement ranges from 6 to 24 h, depending on season and weather conditions. Water vapor spectra are collected using the beam-switching technique. VESPA-22 is designed to operate automatically with little maintenance; it employs an uncooled front-end characterized by a receiver temperature of about 180 K and its quasi-optical system presents a full width at half maximum of 3.5°. Every 30 min VESPA-22 measures also the sky opacity using the tipping curve technique. The instrument calibration is performed automatically by a noise diode; the emission temperature of this element is estimated twice an hour by observing alternatively a black body at ambient temperature and the sky at an elevation of 60°. The retrieved profiles obtained inverting 24 h integration spectra present a sensitivity larger than 0.8 from about 25 to 75 km of altitude during winter and from about 30 to 65 km during summer, a vertical resolution from about 12 to 23 km (depending on altitude, and an overall 1σ uncertainty lower than 7 % up to 60 km altitude and rapidly increasing to 20 % at 75 km. In July 2016, VESPA-22 was installed at the Thule High Arctic Atmospheric Observatory located at Thule Air Base (76.5° N, 68.8° W, Greenland, and it has been operating almost continuously since then. The VESPA-22 water vapor mixing ratio vertical profiles discussed in this work are obtained from 24 h averaged spectra and are compared with version 4.2 of concurrent Aura/Microwave Limb Sounder (MLS water vapor vertical profiles. In the sensitivity range of VESPA-22 retrievals, the intercomparison from July 2016 to July 2017 between VESPA-22 dataset and Aura/MLS dataset

  6. A New ENSO Index Derived from Satellite Measurements of Column Ozone

    Science.gov (United States)

    Ziemke, J. R.; Chandra, S.; Oman, L. D.; Bhartia, P. K.

    2010-01-01

    Column Ozone measured in tropical latitudes from Nimbus 7 total ozone mapping spectrometer (TOMS), Earth Probe TOMS, solar backscatter ultraviolet (SBUV), and Aura ozone monitoring instrument (OMI) are used to derive an El Nino-Southern Oscillation (ENSO) index. This index, which covers a time period from 1979 to the present, is defined as the Ozone ENSO Index (OEI) and is the first developed from atmospheric trace gas measurements. The OEI is constructed by first averaging monthly mean column ozone over two broad regions in the western and eastern Pacific and then taking their difference. This differencing yields a self-calibrating ENSO index which is independent of individual instrument calibration offsets and drifts in measurements over the long record. The combined Aura OMI and MLS ozone data confirm that zonal variability in total column ozone in the tropics caused by ENSO events lies almost entirely in the troposphere. As a result, the OEI can be derived directly from total column ozone instead of tropospheric column ozone. For clear-sky ozone measurements a +1K change in Nino 3.4 index corresponds to +2.9 Dobson Unit (DU) change in the OEI, while a +1 hPa change in SOI coincides with a -1.7DU change in the OEI. For ozone measurements under all cloud conditions these numbers are +2.4DU and -1.4 DU, respectively. As an ENSO index based upon ozone, it is potentially useful in evaluating climate models predicting long term changes in ozone and other trace gases.

  7. Systematic mediastinal lymphadenectomy or mediastinal lymph node sampling in patients with pathological stage I NSCLC: a meta-analysis.

    Science.gov (United States)

    Dong, Siyuan; Du, Jiang; Li, Wenya; Zhang, Shuguang; Zhong, Xinwen; Zhang, Lin

    2015-02-01

    To evaluate the evidence comparing systematic mediastinal lymphadenectomy (SML) and mediastinal lymph node sampling (MLS) in the treatment of pathological stage I NSCLC using meta-analytical techniques. A literature search was undertaken until January 2014 to identify the comparative studies evaluating 1-, 3-, and 5-year survival rates. The pooled odds ratios (OR) and the 95 % confidence intervals (95 % CI) were calculated with either the fixed or random effect models. One RCT study and four retrospective studies were included in our meta-analysis. These studies included a total of 711 patients: 317 treated with SML, and 394 treated with MLS. The SML and the MLS did not demonstrate a significant difference in the 1-year survival rate. There were significant statistical differences between the 3-year (P = 0.03) and 5-year survival rates (P = 0.004), which favored SML. This meta-analysis suggests that in pathological stage I NSCLC, the MLS can get the similar outcome to the SML in terms of 1-year survival rate. However, the SML is superior to MLS in terms of 3- and 5-year survival rates.

  8. Low-grade MALT lymphoma of the stomach: a review of treatment options

    International Nuclear Information System (INIS)

    Schechter, Naomi R.; Yahalom, Joachim

    2000-01-01

    Purpose: Low-grade mucosa-associated lymphoid tissue (MALT) lymphoma of the stomach (MLS) is often associated with the presence of Helicobacter pylori (H. pylori) bacteria. Eradication of the infection with antibiotic therapy may result in regression of the lymphoma. But when antibiotic treatment fails to reverse the malignant process or if H. pylori is absent, other treatment options should be considered. Because MLS is often confined to the stomach and regional lymph nodes, it is potentially curable with local therapy. Endoscopy and improved imaging, with endoscopic ultrasound (EUS) and computerized tomography (CT), have reduced the prior dependence on surgery for diagnosis and staging of gastric lymphomas. Methods and Results: This review details the advances in the diagnosis, classification, and imaging of MLS. We also describe the experience that supports the use of radiation therapy as the preferred treatment of MLS in patients who have not responded to antibiotic therapy or have not had evidence for H. pylori infection. Conclusions: Radiation therapy for MLS is not only effective and safe, but offers the significant advantage of low morbidity and gastric function preservation

  9. Equatorial wave activity during 2007 over Gadanki, a tropical station

    Indian Academy of Sciences (India)

    been used to investigate the wave activity in the troposphere and lower stratosphere. Waves in the ...... Oltmans S J 2001 Water vapor control at the tropopause by equatorial Kelvin .... observed in UARS microwave limb sounder temperature.

  10. Quantitative measurement of hemodynamics of inferior vena in healthy volunteers with phase-contrast MR imaging at 3.0 T

    International Nuclear Information System (INIS)

    Ruan Zhibing; Fan Guangming; Jiao Jun; Min Dingyu

    2014-01-01

    Objective: To explore the feasibility of quantitative hemodynamics measurement of inferior vena cava (IVC) in healthy volunteers with phase-contrast sequence on 3.0 T MR system (3.0 T PC-MRI), and to evaluate the relationship between IVC lumen area, blood flow, and velocity. Methods: Fifty healthy adult volunteers prospective underwent IVC PC-MRI at 3.0 T MR system. All volunteers were from our hospital for the routine chest or abdomen examinations, no heart disease and lung disease always, heart rate, blood pressure, electrocardiogram was in normal range, no abnormalities were found in clinical and abdominal imaging examinations, and IVC disease was excluded by ultrasonic examination. The area (A), mean velocity (MV), mean flux (MF), regurgitant fraction (RF) and time-flow curve of upper and middle segments of IVC during one cardiac cycle were observed. Independent samples t test was used to compare IVC lumen area and blood flow, velocity between different genders, different age groups (18 to 30 years old group, more than 30 years old group) and different phase velocity encoding value of IVC middle segment, one-way ANOVA was used to compare different phase velocity encoding value of IVC upper segment [(60, 80, 100)cm/s]. Pearson correlation coefficient and regression equation were used to evaluate the relationships between area, blood flow, and velocity. Results: Among 50 patients with successful completion of the examination, significant difference was found in A, MV, MF and RF between the different IVC segments. MF of the IVC middle segment were (37.94 ± 7.32) and (33.68 ± 6.65) ml/s in male (n=24) and female (n=26), respectively; significant difference was found in different genders (t=2.49, P=0.017). MF of upper segment and middle segments of IVC were (54.89 ± 10.98) and (38.29 ± 7.54) ml/s in 18 to 30 years old group (n=27), while MF of upper segment and the middle of IVC were (44.96 ± 8.49) and (32.65 ± 5.59) ml/s in older than 30 years old group (n=23

  11. Multi-detector row CT of the head and neck: comparison of different volumes of contrast material with and without a saline chaser

    International Nuclear Information System (INIS)

    Yoon, Dae Young; You, Su Yeon; Choi, Chul Soon; Chang, Suk Ki; Yun, Eun Joo; Seo, Young Lan; Park, Sang Joon; Lee, Yu-Jin; Moon, Jeung Hee; Rho, Young-Soo; Kim, Jin-Hwan

    2006-01-01

    The aim of this study was to determine the effect of different volumes of contrast material with and without a saline chaser on tissue enhancement in multidetector row CT (MDCT) of the head and neck. In a blind prospective fashion, 120 patients were randomized into the following four groups: group 1, 80 ml contrast material administered at a flow rate of 2.0 ml/s; group 2, 80 ml followed by 40 ml saline at 2.0 ml/s; group 3, 60 ml at 1.5 ml/s; and group 4, 60 ml followed by 30 ml saline at 1.5 ml/s. The attenuation values of the carotid artery, internal jugular vein, and muscle were measured at an interval of 1.5 s in each patient. The degree of perivenous artifacts was subjectively assessed. Mean attenuation values in the carotid artery and internal jugular vein were significantly higher in groups 1 and 2 than in groups 3 and 4. The width of the diagnostic window (both carotid and jugular enhancement >150 HU) were significantly longer in groups 1 and 2 than in groups 3 and 4. The addition of a saline chaser did not result in improved vascular enhancement or a wider diagnostic window, but reduced perivenous artifacts, compared with using contrast material alone. Reduction of contrast material from 80 to 60 ml results in insufficient enhancement of neck vessels. In addition, the benefit of a saline chaser technique is not obvious except for its ability to reduce perivenous artifacts. (orig.)

  12. Terminal area automatic navigation, guidance, and control research using the Microwave Landing System (MLS). Part 2: RNAV/MLS transition problems for aircraft

    Science.gov (United States)

    Pines, S.

    1982-01-01

    The problems in navigation and guidance encountered by aircraft in the initial transition period in changing from distance measuring equipment, VORTAC, and barometric instruments to the more precise microwave landing system data type navaids in the terminal area are investigated. The effects of the resulting discontinuities on the estimates of position and velocity for both optimal (Kalman type navigation schemes) and fixed gain (complementary type) navigation filters, and the effects of the errors in cross track, track angle, and altitude on the guidance equation and control commands during the critical landing phase are discussed. A method is presented to remove the discontinuities from the navigation loop and to reconstruct an RNAV path designed to land the aircraft with minimal turns and altitude changes.

  13. A fenestration approach to arytenoid adduction for unilateral vocal cord paralysis. Results of 32 cases

    International Nuclear Information System (INIS)

    Motohashi, Ray; Tokashiki, Ryoji; Hiramatsu, Hiroyuki; Nakamura, Mari; Funato, Nobutoshi; Suzuki, Mamoru

    2009-01-01

    The objective of this study was to develop and evaluate the voice outcomes of an approach to arytenoid adduction (AA) for unilateral vocal cord paralysis through fenestration of the thyroid ala. Thirty-two patients with unilateral vocal cord paralysis underwent laryngoplasty using an approach to AA performed through fenestration of the thyroid ala combined with type I thyroplasty. Thirty-two patients with unilateral vocal cord paralysis were treated between October 2004 and February 2008. In all cases, maximum phonation time (MPT) and mean airflow rate (MFR) were measured before and after the operation. The voices were analyzed using shimmer and jitter. Two surgical windows were made in the lower part of the thyroid ala. The anterior one was for typical type I thyroplasty and the posterior one was for arytenoid adduction (AA). The locations of the two windows were determined based on three-dimensional computer tomography (3DCT) data. AA was performed by muscular process through the posterior window without releasing the cricothyroid joint. The operations were performed under local anesthesia with sedation. Vocal cord medialization was confirmed endoscopically during the operation. Twenty-nine of the 32 patients achieved an MPT of over 10 s after surgery. The other 3 cases, whose MPTs were 9 s after the operation, had low breathing capacity because of lung disease and normal side vocal cord sulcus. The MFRs, which ranged from 236 to 1908 ml/s before the operation, improved to under 200 ml/s except in 3 patients, whose MFRs were 210 ml/s, 214 ml/s and 216 ml/s. Jitter and shimmer improved significantly after the operation. Perceptual evaluation using the GRBAS scale also improved significantly. Our new procedure simplified the combination of AA and type I thyroplasty because the two treatments can be performed in the same operating field, obtaining good voice improvement. Determination of the surgical approach using 3DCT and endoscopic vocal cord observation may

  14. Multilamellar structures and filament bundles are found on the cell surface during bunyavirus egress.

    Directory of Open Access Journals (Sweden)

    Laura Sanz-Sánchez

    Full Text Available Inside cells, viruses build specialized compartments for replication and morphogenesis. We observed that virus release associates with specific structures found on the surface of mammalian cells. Cultured adherent cells were infected with a bunyavirus and processed for oriented sectioning and transmission electron microscopy. Imaging of cell basal regions showed sophisticated multilamellar structures (MLS and extracellular filament bundles with attached viruses. Correlative light and electron microscopy confirmed that both MLS and filaments proliferated during the maximum egress of new viruses. MLS dimensions and structure were reminiscent of those reported for the nanostructures on gecko fingertips, which are responsible for the extraordinary attachment capacity of these lizards. As infected cells with MLS were more resistant to detachment than control cells, we propose an adhesive function for these structures, which would compensate for the loss of adherence during release of new virus progeny.

  15. NCBI nr-aa BLAST: CBRC-TTRU-01-0561 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-TTRU-01-0561 ref|ZP_02171569.1| integral membrane protein-like protein [Bacillus selenitire...ducens MLS10] gb|EDP81850.1| integral membrane protein-like protein [Bacillus selenitireducens MLS10] ZP_02171569.1 0.089 25% ...

  16. NCBI nr-aa BLAST: CBRC-TTRU-01-0188 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-TTRU-01-0188 ref|ZP_02171569.1| integral membrane protein-like protein [Bacillus selenitire...ducens MLS10] gb|EDP81850.1| integral membrane protein-like protein [Bacillus selenitireducens MLS10] ZP_02171569.1 0.019 29% ...

  17. NCBI nr-aa BLAST: CBRC-TTRU-01-0898 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-TTRU-01-0898 ref|ZP_02171569.1| integral membrane protein-like protein [Bacillus selenitire...ducens MLS10] gb|EDP81850.1| integral membrane protein-like protein [Bacillus selenitireducens MLS10] ZP_02171569.1 6e-05 28% ...

  18. Six years of mesospheric CO estimated from ground-based frequency-switched microwave radiometry at 57° N compared with satellite instruments

    Directory of Open Access Journals (Sweden)

    P. Forkman

    2012-11-01

    Full Text Available Measurements of mesospheric carbon monoxide, CO, provide important information about the dynamics in the mesosphere region since CO has a long lifetime at these altitudes. Ground-based measurements of mesospheric CO made at the Onsala Space Observatory, OSO, (57° N, 12° E are presented. The dataset covers the period 2002–2008 and is hence uniquely long for ground-based observations. The simple and stable 115 GHz frequency-switched radiometer, calibration method, retrieval procedure and error characterization are described. A comparison between our measurements and co-located CO measurements from the satellite sensors ACE-FTS on Scisat (v2.2, MLS on Aura (v3-3, MIPAS on Envisat (V3O_CO_12 + 13 and V4O_CO_200 and SMR on Odin (v225 and v021 is carried out. Our instrument, OSO, and the four satellite instruments show the same general variation of the vertical distribution of mesospheric CO in both the annual cycle and in shorter time period events, with high CO mixing ratios during winter and very low amounts during summer in the observed 55–100 km altitude range. During 2004–2008 the agreement of the OSO instrument and the satellite sensors ACE-FTS, MLS and MIPAS (200 is good in the altitude range 55–70 km. Above 70 km, OSO shows up to 25% higher CO column values compared to both ACE and MLS. For the time period 2002–2004, CO from MIPAS (12 + 13 is up to 50% lower than OSO between 55 and 70 km. Mesospheric CO from the two versions of SMR deviates up to ±65% when compared to OSO, but the analysis is based on only a few co-locations.

  19. Six years of mesospheric CO estimated from ground-based frequency-switched microwave radiometry at 57° N compared with satellite instruments

    Science.gov (United States)

    Forkman, P.; Christensen, O. M.; Eriksson, P.; Urban, J.; Funke, B.

    2012-11-01

    Measurements of mesospheric carbon monoxide, CO, provide important information about the dynamics in the mesosphere region since CO has a long lifetime at these altitudes. Ground-based measurements of mesospheric CO made at the Onsala Space Observatory, OSO, (57° N, 12° E) are presented. The dataset covers the period 2002-2008 and is hence uniquely long for ground-based observations. The simple and stable 115 GHz frequency-switched radiometer, calibration method, retrieval procedure and error characterization are described. A comparison between our measurements and co-located CO measurements from the satellite sensors ACE-FTS on Scisat (v2.2), MLS on Aura (v3-3), MIPAS on Envisat (V3O_CO_12 + 13 and V4O_CO_200) and SMR on Odin (v225 and v021) is carried out. Our instrument, OSO, and the four satellite instruments show the same general variation of the vertical distribution of mesospheric CO in both the annual cycle and in shorter time period events, with high CO mixing ratios during winter and very low amounts during summer in the observed 55-100 km altitude range. During 2004-2008 the agreement of the OSO instrument and the satellite sensors ACE-FTS, MLS and MIPAS (200) is good in the altitude range 55-70 km. Above 70 km, OSO shows up to 25% higher CO column values compared to both ACE and MLS. For the time period 2002-2004, CO from MIPAS (12 + 13) is up to 50% lower than OSO between 55 and 70 km. Mesospheric CO from the two versions of SMR deviates up to ±65% when compared to OSO, but the analysis is based on only a few co-locations.

  20. Interactive modelling with stakeholders in two cases in flood management

    Science.gov (United States)

    Leskens, Johannes; Brugnach, Marcela

    2013-04-01

    New policies on flood management called Multi-Level Safety (MLS), demand for an integral and collaborative approach. The goal of MLS is to minimize flood risks by a coherent package of protection measures, crisis management and flood resilience measures. To achieve this, various stakeholders, such as water boards, municipalities and provinces, have to collaborate in composing these measures. Besides the many advances this integral and collaborative approach gives, the decision-making environment becomes also more complex. Participants have to consider more criteria than they used to do and have to take a wide network of participants into account, all with specific perspectives, cultures and preferences. In response, sophisticated models are developed to support decision-makers in grasping this complexity. These models provide predictions of flood events and offer the opportunity to test the effectiveness of various measures under different criteria. Recent model advances in computation speed and model flexibility allow stakeholders to directly interact with a hydrological hydraulic model during meetings. Besides a better understanding of the decision content, these interactive models are supposed to support the incorporation of stakeholder knowledge in modelling and to support mutual understanding of different perspectives of stakeholders To explore the support of interactive modelling in integral and collaborate policies, such as MLS, we tested a prototype of an interactive flood model (3Di) with respect to a conventional model (Sobek) in two cases. The two cases included the designing of flood protection measures in Amsterdam and a flood event exercise in Delft. These case studies yielded two main results. First, we observed that in the exploration phase of a decision-making process, stakeholders participated actively in interactive modelling sessions. This increased the technical understanding of complex problems and the insight in the effectiveness of various

  1. 77 FR 23658 - Six Rivers National Forest, Gasquet Ranger District, California, The Smith River National...

    Science.gov (United States)

    2012-04-20

    ... National Forest, Gasquet Ranger District, California, The Smith River National Recreation Area [email protected] . Please insure that ``Smith River NRA Restoration and Motorized Travel Management'' occurs... UARs totaling 80 miles. The project encompasses the Smith River NRA and Gasquet Ranger District...

  2. SLAM-Aided Stem Mapping for Forest Inventory with Small-Footprint Mobile LiDAR

    Directory of Open Access Journals (Sweden)

    Jian Tang

    2015-12-01

    Full Text Available Accurately retrieving tree stem location distributions is a basic requirement for biomass estimation of forest inventory. Combining Inertial Measurement Units (IMU with Global Navigation Satellite Systems (GNSS is a commonly used positioning strategy in most Mobile Laser Scanning (MLS systems for accurate forest mapping. Coupled with a tactical or consumer grade IMU, GNSS offers a satisfactory solution in open forest environments, for which positioning accuracy better than one decimeter can be achieved. However, for such MLS systems, positioning in a mature and dense forest is still a challenging task because of the loss of GNSS signals attenuated by thick canopy. Most often laser scanning sensors in MLS systems are used for mapping and modelling rather than positioning. In this paper, we investigate a Simultaneous Localization and Mapping (SLAM-aided positioning solution with point clouds collected by a small-footprint LiDAR. Based on the field test data, we evaluate the potential of SLAM positioning and mapping in forest inventories. The results show that the positioning accuracy in the selected test field is improved by 38% compared to that of a traditional tactical grade IMU + GNSS positioning system in a mature forest environment and, as a result, we are able to produce a unambiguous tree distribution map.

  3. New helical-shape magnetic pole design for Magnetic Lead Screw enabling structure simplification

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Xia, Yongming; Wu, Weimin

    2015-01-01

    Magnetic lead screw (MLS) is a new type of high performance linear actuator that is attractive for many potential applications. The main difficulty of the MLS technology lies in the manufacturing of its complicated helical-shape magnetic poles. Structure simplification is, therefore, quite...

  4. Detection of Macrolide, Lincosamide and Streptogramin Resistance among Methicillin Resistant Staphylococcus aureus (MRSA in Mumbai

    Directory of Open Access Journals (Sweden)

    Arunagiri Subramanian

    2015-01-01

    Full Text Available Background: The increase in incidence of Methicillin Resistant Staphyloccocus aureus (MRSA and its extraordinary potential to develop antimicrobial resistance has highlighted the need for better agents to treat such infections. This has led to a renewed interest in use of new drugs for treatment with clindamycin and quinuprsitin-dalfopristin being the preferred choice for treatment. Aim & Objectives: This study was undertaken to detect the prevalence of MacrolideLincosamide-Streptogramin (MLS resistance among clinical isolates of MRSA.Material and Methods:Two hundred and thirty clinical isolates of S. aureus were subjected to routine antibiotic susceptibility testing including cefoxitin, erythromycin and quinupristindalfopristin. Inducible resistance to clindamycin was tested by 'D' test as per Clinical and Laboratory Standards Institute (CLSI guidelines. Results: Out of all S. aureus isolates, 93.91% were identified as MRSA. In the disc diffusion testing, 81.5% of isolates showed erythromycin resistance. Among these, the prevalence of constitutive (cMLS , inducible (iMLS b b and MS-phenotype were 35.80%, 31.82% and 32.39% respectively by the D-test method. 77.8% of isolates were resistant to quinupristin-dalfopristin and the Minimum Inhibitory Concentration (MIC ranged from 4–32 µg/ml. 89.20% of isolates were resistant to both quinupristin-dalfopristin and erythromycin of which 35.03%, 35.67% and 29.30% belonged to iMLS , cMLS and MS phenotype respectively. Conclusion: The emergence of quinupristindalfopristin resistance and MLS phenotypes brings b about the need for the simple and reliable D-test in routine diagnosis and further susceptibility testing for proper antimicrobial therapy.

  5. Cadaver embalming fluid for surgical training courses: modified Larssen solution.

    Science.gov (United States)

    Bilge, Okan; Celik, Servet

    2017-11-01

    10% Formalin (F10)-fixed cadavers have disadvantages such as disturbing smell, mucosal irritation, discoloration and rigidity. We aimed to determine a suitable, simple and cost-effective embalming method that preserves color, texture, pliability and flexibility of the tissues for a long time without a disturbing smell and mucosal irritation. The embalmed cadavers were expected to be durable against environmental effects, utilizable for multiple and repetitive surgical trainings and instrumentations. Eight male (six intact, two autopsied bodies) and four female (three intact and one imported trunk) human cadavers were preserved with modified Larssen solution (MLS). Preserved bodies were kept in the deep freezers at -18/-20 °C. Bodies were allowed to thaw at room temperature 3 days prior to use. They were used in postgraduate hands-on courses for several medical disciplines. Each course lasted at least 1 day and during this period the bodies were stayed at room temperature. Assessments of 30 trainers and 252 trainees were collected during the courses. Additionally, the organoleptic characteristics of the fresh frozen (FF), preserved with MLS and F10-fixed cadavers were compared. The colors of muscles, fasciae, fatty tissue, nerves and vessels were evaluated and life-like tissues of MLS cadavers were impressive. There were no obvious or disturbing smell and sign of putrefaction of the MLS cadavers. MLS is a sustainable and relatively affordable soft cadaver embalming method. Its application is same as in other conventional methods and does not need new equipment. This article indicates the success of the MLS method in human cadavers.

  6. Effects of the 2004 El Nino on tropospheric ozone and water vapor

    NARCIS (Netherlands)

    Chandra, S.; Ziemke, J.R.; Schoeberl, M.R.; Froidevaux, L.; Read, W.G.; Levelt, P.F.; Bhartia, P.K.

    2007-01-01

    The global effects of the 2004 El Nino on tropospheric ozone and H/sub 2/O based on Aura OMI and MLS measurements are analyzed. Although it was a weak El Nino from a historical perspective, it produced significant changes in these parameters in tropical latitudes. Tropospheric ozone increased by

  7. Shielding for neutrons produced by medical linear accelerators

    International Nuclear Information System (INIS)

    Rebello, Wilson F.; Silva, Ademir X.

    2007-01-01

    The shielding system called Multileaf Shielding (MLS) was designed in Brazil to be used for protection patients, who undergo radiotherapy treatment, against undesired neutrons produced in the medical linear accelerator heads. During the conceiving of the MLS it was necessary to evaluate its efficiency. For that purpose, several simulations using the Monte Carlo N-particle radiation transport code, MCNP5, were made, in order to evaluate the response of the new shielding system. The results showed a significant neutron dose reduction after the inclusion of the MLS. This work aims to presenting these simulation results. (author)

  8. A FEASIBILITY STUDY ON USE OF GENERIC MOBILE LASER SCANNING SYSTEM FOR DETECTING ASPHALT PAVEMENT CRACKS

    Directory of Open Access Journals (Sweden)

    X. Chen

    2016-06-01

    Full Text Available This study aims to automatically detect pavement cracks on urban roads by employing the 3D point clouds acquired by a mobile laser scanning (MLS system. Our method consists of four steps: ground point filtering, high-pass convolution, matched filtering, and noise removal. First, a voxel-based upward growing method is applied to construct Digital Terrain Model (DTM of the road surface. Then, a high-pass filter convolutes the DTM to detect local elevation changes that may embed cracking information. Next, a two-step matched filter is applied to extract crack features. Lastly, a noise removal process is conducted to refine the results. Instead of using MLS intensity, this study takes advantages of the MLS elevation information to perform automated crack detection from large-volume, mixed-density, unstructured MLS point clouds. Four types of cracks including longitudinal, transvers, random, and alligator cracks are detected. Our results demonstrated that the proposed method works well with the RIEGL VMX-450 point clouds and can detect cracks in moderate-to-severe severity (13 - 25 mm within a 200 m by 30 m urban road segment located in Kingston, Ontario, at one time. Due to the resolution capability, small cracks with slight severity remain unclear in the MLS point cloud.

  9. Multi-Level Security Cannot Realise NEC Objectives

    NARCIS (Netherlands)

    Schotanus, H.A.; Hartog, T.; Verkoelen, C.A.A.

    2012-01-01

    Multi-Level Security (MLS) is often viewed as the holy grail of information security, especially in those environments where information of different classifications is being processed. In this paper we argue that MLS cannot facilitate the right balance between need-to-protect and duty-to-share as

  10. Northern Hemisphere Atmospheric Influence of the Solar Proton Events and Ground Level Enhancement in January 2005

    Science.gov (United States)

    Jackman, C. H.; Marsh, D. R.; Vitt, F. M.; Roble, R. G.; Randall, C. E.; Bernath, P. F.; Funke, B.; Lopez-Puertas, M.; Versick, S.; Stiller, G. P.; hide

    2011-01-01

    Solar eruptions in early 2005 led substantial barrage of charged particles on the Earth's atmosphere during the January 16-21 period. Proton fluxes were greatly increased during these several days and led to the production ofHO(x)(H, OH, BO2)and NO(x)(N, NO, NO2), which then caused the destruction of ozone. We focus on the Northern polar region, where satellite measurements and simulations with the Whole Atmosphere Community Climate Model (WACCM3) showed large enhancements in mesospheric HO(x) and NO(x) constituents, and associated ozone reductions, due 10 these solar proton events (SPEs). The WACCM3 simulations show enhanced short-lived OH throughout the mesosphere in the 60-82.5degN latitude band due to the SPEs for most days in the Jan.16-2l,2005 period, in reasonable agreement with the Aura Microwave Limb Sounder (MLS) measurements. Mesospheric HO2 is also predicted to be increased by the SPEs, however, the modeled HO2 results are somewhat larger than the MLS measurements. These HO(x) enhancements led to huge predicted and MLS-measured ozone decreases of greater than 40% throughout most of the Northern polar mesosphere during the SPE period. Envisat Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) measurements of hydrogen peroxide (H2O2) show increases throughout the stratosphere with highest enhancements of about 60 ppt y in the lowermost mesosphere over the Jan. 16-18, 2005 period due to the solar protons. WACCM3 predictions indicate H2O2 enhancements over the same time period of more than twice that amount. Measurements of nitric acid (HNO3) by both MLS and MIPAS show an increase of about 1 ppbv above background levels in the upper stratosphere during January 16-29, 2005. WACCM3 simulations show only minuscule HNO3 changes in the upper stratosphere during this time period. However due to the small loss rates during winter, polar mesospheric enhancements of NO(x) are computed to be greater than 50 ppbv during the SPE period. Computed NO

  11. Correlation of psychomotor findings and the ability to partially weight bear

    Science.gov (United States)

    2012-01-01

    Background Partial weight bearing is thought to avoid excessive loading that may interfere with the healing process after surgery of the pelvis or the lower extremity. The object of this study was to investigate the relationship between the ability to partially weight bear and the patient's psychomotor skills and an additional evaluation of the possibility to predict this ability with a standardized psychomotor test. Methods 50 patients with a prescribed partial weight bearing at a target load of 15 kg following surgery were verbally instructed by a physical therapist. After the instruction and sufficient training with the physical therapist vertical ground reaction forces using matrix insoles were measured while walking with forearm crutches. Additionally, psychomotor skills were tested with the Motorische Leistungsserie (MLS). To test for correlations Spearman's Rank correlation was used. For further comparison of the two groups a Mann-Withney test was performed using Bonferroni correction. Results The patient's age and body weight significantly correlated with the ability to partially weight bear at a 15 kg target load. There were significant correlations between several subtests of the MLS and ground reaction forces measured while walking with crutches. Patients that were able to correctly perform partial weight bearing showed significant better psychomotor skills especially for those subtests where both hands had to be coordinated simultaneously. Conclusions The ability to partially weight bear is associated with psychomotor skills. The MLS seems to be a tool that helps predicting the ability to keep within the prescribed load limits. PMID:22330655

  12. Correlation of psychomotor findings and the ability to partially weight bear

    Directory of Open Access Journals (Sweden)

    Ruckstuhl Thomas

    2012-02-01

    Full Text Available Abstract Background Partial weight bearing is thought to avoid excessive loading that may interfere with the healing process after surgery of the pelvis or the lower extremity. The object of this study was to investigate the relationship between the ability to partially weight bear and the patient's psychomotor skills and an additional evaluation of the possibility to predict this ability with a standardized psychomotor test. Methods 50 patients with a prescribed partial weight bearing at a target load of 15 kg following surgery were verbally instructed by a physical therapist. After the instruction and sufficient training with the physical therapist vertical ground reaction forces using matrix insoles were measured while walking with forearm crutches. Additionally, psychomotor skills were tested with the Motorische Leistungsserie (MLS. To test for correlations Spearman's Rank correlation was used. For further comparison of the two groups a Mann-Withney test was performed using Bonferroni correction. Results The patient's age and body weight significantly correlated with the ability to partially weight bear at a 15 kg target load. There were significant correlations between several subtests of the MLS and ground reaction forces measured while walking with crutches. Patients that were able to correctly perform partial weight bearing showed significant better psychomotor skills especially for those subtests where both hands had to be coordinated simultaneously. Conclusions The ability to partially weight bear is associated with psychomotor skills. The MLS seems to be a tool that helps predicting the ability to keep within the prescribed load limits.

  13. Well separated trion and neutral excitons on superacid treated MoS{sub 2} monolayers

    Energy Technology Data Exchange (ETDEWEB)

    Cadiz, Fabian, E-mail: cadiz@insa-toulouse.fr; Tricard, Simon; Gay, Maxime; Lagarde, Delphine; Wang, Gang; Robert, Cedric; Renucci, Pierre; Urbaszek, Bernhard; Marie, Xavier [Université de Toulouse, INSA-CNRS-UPS, LPCNO, 135 Av. Rangueil, 31077 Toulouse (France)

    2016-06-20

    Developments in optoelectronics and spin-optronics based on transition metal dichalcogenide monolayers (MLs) need materials with efficient optical emission and well-defined transition energies. In as-exfoliated MoS{sub 2} MLs, the photoluminescence (PL) spectra even at low temperature consist typically of broad, overlapping contributions from neutral, charged excitons (trions) and localized states. Here, we show that in superacid treated MoS{sub 2} MLs, the PL intensity increases by up to 60 times at room temperature. The neutral and charged exciton transitions are spectrally well separated in PL and reflectivity at T = 4 K, with linewidth for the neutral exciton of 15 meV, but both transitions have similar intensities compared to the ones in as-exfoliated MLs at the same temperature. Time resolved experiments uncover picoseconds recombination dynamics analyzed separately for charged and neutral exciton emissions. Using the chiral interband selection rules, we demonstrate optically induced valley polarization for both complexes and valley coherence for only the neutral exciton.

  14. NASA-FAA helicopter Microwave Landing System curved path flight test

    Science.gov (United States)

    Swenson, H. N.; Hamlin, J. R.; Wilson, G. W.

    1984-01-01

    An ongoing series of joint NASA/FAA helicopter Microwave Landing System (MLS) flight tests was conducted at Ames Research Center. This paper deals with tests done from the spring through the fall of 1983. This flight test investigated and developed solutions to the problem of manually flying curved-path and steep glide slope approaches into the terminal area using the MLS and flight director guidance. An MLS-equipped Bell UH-1H helicopter flown by NASA test pilots was used to develop approaches and procedures for flying these approaches. The approaches took the form of Straight-in, U-turn, and S-turn flightpaths with glide slopes of 6 deg, 9 deg, and 12 deg. These procedures were evaluated by 18 pilots from various elements of the helicopter community, flying a total of 221 hooded instrument approaches. Flying these curved path and steep glide slopes was found to be operationally acceptable with flight director guidance using the MLS.

  15. Classification of Mobile Laser Scanning Point Clouds from Height Features

    Science.gov (United States)

    Zheng, M.; Lemmens, M.; van Oosterom, P.

    2017-09-01

    The demand for 3D maps of cities and road networks is steadily growing and mobile laser scanning (MLS) systems are often the preferred geo-data acquisition method for capturing such scenes. Because MLS systems are mounted on cars or vans they can acquire billions of points of road scenes within a few hours of survey. Manual processing of point clouds is labour intensive and thus time consuming and expensive. Hence, the need for rapid and automated methods for 3D mapping of dense point clouds is growing exponentially. The last five years the research on automated 3D mapping of MLS data has tremendously intensified. In this paper, we present our work on automated classification of MLS point clouds. In the present stage of the research we exploited three features - two height components and one reflectance value, and achieved an overall accuracy of 73 %, which is really encouraging for further refining our approach.

  16. Preventive effects of lansoprazole and famotidine on gastric mucosal injury induced by low-dose aspirin in Helicobacter pylori-negative healthy volunteers.

    Science.gov (United States)

    Nishino, Masafumi; Sugimoto, Mitsushige; Kodaira, Chise; Yamade, Mihoko; Uotani, Takahiro; Shirai, Naohito; Ikuma, Mutsuhiro; Tanaka, Tatsuo; Sugimura, Haruhiko; Hishida, Akira; Furuta, Takahisa

    2011-07-01

    The preventive effects of lansoprazole and famotidine on low-dose aspirin-induced gastric mucosal injury in relation to gastric acidity were compared in healthy Japanese volunteers. Fifteen Helicobacter pylori-negative volunteers with different CYP2C19 genotypes were randomly administered aspirin 100 mg, aspirin plus famotidine 20 mg twice daily, or aspirin plus lansoprazole 15 mg once daily for 7 days each in a crossover fashion. Gastroscopy for the evaluation of mucosal injury based on modified Lanza score (MLS) and 24-hour intragastric pH monitoring were performed on day 7 of each regimen. Aspirin induced gastric mucosal injury (median MLS = 3). Lansoprazole significantly decreased MLS to 0, which was significantly lower than that by famotidine (MLS = 1) (P lansoprazole regimen were significantly higher than those with famotidine (P lansoprazole appeared to be more protective than famotidine against low-dose aspirin-induced mucosal injury but a larger well-controlled study is necessary to establish a definitive clinical benefit.

  17. Inducible clindamycin and methicillin resistant Staphylococcus aureus in a tertiary care hospital, Kathmandu, Nepal.

    Science.gov (United States)

    Adhikari, R P; Shrestha, S; Barakoti, A; Amatya, R

    2017-07-11

    Staphylococcus aureus, an important nosocomial pathogen, is frequently associated with infections in human. The management of the infections by it especially methicillin resistant ones is often difficult because methicillin resistant S. aureus is usually resistant to multiple antibiotics. Macrolide-lincosamide streptogramin B family of antibiotics is commonly used to treat such infections as an alternative to vancomycin. This study was conducted over the period of one and half year from November 2013-April 2015 in Microbiology laboratory of Nepal Medical College and Teaching Hospital, Kathmandu, Nepal to find the incidence of different phenotypes of MLS B resistance among S. aureus from clinical samples and their association with methicillin resistance. Two hundred seventy isolates of S. aureus were included in the study. Methicillin resistance was detected by cefoxitin disc diffusion method and inducible clindamycin resistance by erythromycin and clindamycin disc approximation test (D-test). Of the 270 clinical isolates of S. aureus, 25.1% (68/270) were MRSA. Erythromycin and clindamycin resistance was seen in 54.4% (147/270) and 41.8% (113/270) isolates respectively. Resistance to erythromycin and clindamycin were higher in MRSA as compared to MSSA (erythromycin-resistance: 88.2% Vs 39.1% and clindamycin-resistance: 79.4% Vs 41.8%). The overall prevalence of i MLS B and c MLS B phenotype was 11.48% (31/270) and 29.25% (79/270) respectively. Both i MLS B and c MLS B phenotypes predominated in MRSA strains. Detection rate of MRSA in our study shows the necessity to improve in healthcare practices and to formulate new policy for the control of MRSA infections. Clindamycin resistance in the form of i MLS B and c MLS B especially among MRSA emphasizes the need of D-test to be performed routinely in our set up while using clindamycin as an alternative choice to anti-staphylococcal antibiotics like vancomycin and linezolid in the treatment of staphylococcal infections.

  18. 14 CFR 171.321 - DME and marker beacon performance requirements.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false DME and marker beacon performance... (MLS) § 171.321 DME and marker beacon performance requirements. (a) The DME equipment must meet the..._regulations/ibr_locations.html. (b) MLS marker beacon equipment must meet the performance requirements...

  19. High School Students' Scientific Epistemological Beliefs, Motivation in Learning Science, and Their Relationships: A Comparative Study within the Chinese Culture

    Science.gov (United States)

    Lin, Tzung-Jin; Deng, Feng; Chai, Ching Sing; Tsai, Chin-Chung

    2013-01-01

    This study explored the differences in high school students' scientific epistemological beliefs (SEBs), motivation in learning science (MLS), and the different relationships between them in Taiwan and China. 310 Taiwanese and 302 Chinese high school students' SEBs and MLS were assessed quantitatively. Taiwanese students generally were more prone…

  20. Effect of different saline chaser volumes and flow rates on intravascular contrast enhancement in CT using a circulation phantom

    International Nuclear Information System (INIS)

    Behrendt, Florian F.; Bruners, Philipp; Keil, Sebastian; Plumhans, Cedric; Mahnken, Andreas H.; Das, Marco; Ackermann, Diana; Guenther, Rolf W.; Muehlenbruch, Georg

    2010-01-01

    Purpose: To evaluate the influence of different saline chaser volumes and different saline chaser flow rates on the intravascular contrast enhancement in MDCT. Materials and methods: In a physiological flow phantom contrast medium (120 ml, 300 mgI/ml, Ultravist 300) was administered at a flow rate of 6 ml/s followed by different saline chaser volumes (0, 30, 60 and 90 ml) at the same injection rate or followed by a 30-ml saline chaser at different injection rates (2, 4, 6 and 8 ml/s). Serial CT-scans at a level covering the pulmonary artery, the ascending and the descending aorta replica were obtained. Time-enhancement curves were computed and both pulmonary and aortic peak enhancement and peak time were determined. Results: Compared to contrast medium injection without a saline chaser the pushing with a saline chaser (30, 60, and 90 ml) resulted in a statistically significant increased pulmonary peak enhancement (all p = 0.008) and prolonged peak time (p = 0.032, p = 0.024 and p = 0.008, respectively). Highest aortic peak enhancement values were detected for a saline chaser volume of 30 ml. A saline chaser flow rate of 8 ml/s resulted in the highest pulmonary peak enhancement values compared to flow rates of 2, 4 and 6 ml/s (all p = 0.008). Aortic peak enhancement showed the highest values for a flow rate of 6 ml/s. Conclusion: A saline chaser volume of 30 ml and an injection rate of 6 ml/s are sufficient to best improve vascular contrast enhancement in the pulmonary artery and the aorta in MDCT.

  1. Characterization of Minnesota lunar simulant for plant growth

    Science.gov (United States)

    Oglesby, James P.; Lindsay, Willard L.; Sadeh, Willy Z.

    1993-01-01

    Processing of lunar regolith into a plant growth medium is crucial in the development of a regenerative life support system for a lunar base. Plants, which are the core of such a system, produce food and oxygen for humans and, at the same time, consume carbon dioxide. Because of the scarcity of lunar regolith, simulants must be used to infer its properties and to develop procedures for weathering and chemical analyses. The Minnesota Lunar Simulant (MLS) has been identified to date as the best available simulant for lunar regolith. Results of the dissolution studies reveal that appropriately fertilized MLS can be a suitable medium for plant growth. The techniques used in conducting these studies can be extended to investigate the suitability of actual lunar regolith as a plant growth medium. Dissolution experiments were conducted using the MLS to determine its nutritional and toxicity characteristics for plant growth and to develop weathering and chemical analysis techniques. Two weathering regimes, one with water and one with dilute organic acids simulating the root rhizosphere microenvironment, were investigated. Elemental concentrations were measured using inductively-coupled-plasma (ICP) emission spectrometry and ion chromatography (IC). The geochemical speciation model, MINTEQA2, was used to determine the major solution species and the minerals controlling them. Acidification was found to be a useful method for increasing cation concentrations to meaningful levels. Initial results indicate that MLS weathers to give neutral to slightly basic solutions which contain acceptable amounts of the essential elements required for plant nutrition (i.e., potassium, calcium, magnesium, sulfur, zinc, sodium, silicon, manganese, copper, chlorine, boron, molybdenum, and cobalt). Elements that need to be supplemented include carbon, nitrogen, and perhaps phosphorus and iron. Trace metals in solution were present at nontoxic levels.

  2. Cross-sectional measures and modelled estimates of blood alcohol levels in UK nightlife and their relationships with drinking behaviours and observed signs of inebriation

    Directory of Open Access Journals (Sweden)

    Jarman Ian

    2010-04-01

    Full Text Available Abstract Background Management of nightlife in UK cities focuses on creating safe places for individuals to drink. Little is known about intoxication levels as measuring total alcohol consumption on nights out is complicated by early evening interviews missing subsequent consumption and later interviews risking individuals being too drunk to recall consumption or participate at all. Here we assess mixed survey and modelling techniques as a methodological approach to examining these issues. Methods Interviews with a cross sectional sample of nightlife patrons (n = 214 recruited at different locations in three cities established alcohol consumption patterns up to the point of interview, self-assessed drunkenness and intended drinking patterns throughout the remaining night out. Researchers observed individuals' behaviours to independently assess drunkenness. Breath alcohol tests and general linear modelling were used to model blood alcohol levels at participants' expected time of leaving nightlife settings. Results At interview 49.53% of individuals regarded themselves as drunk and 79.43% intended to consume more alcohol before returning home, with around one in ten individuals (15.38% males; 4.35% females intending to consume >40 units (equal to 400 mls of pure alcohol. Self-assessed drunkenness, researcher observed measures of sobriety and blood alcohol levels all correlated well. Modelled estimates for blood alcohol at time of going home suggested that 71.68% of males would be over 0.15%BAC (gms alcohol/100 mls blood. Higher blood alcohol levels were related to drinking later into the night. Conclusions UK nightlife has used substantive health and judicial resources with the aim of creating safer and later drinking environments. Survey and modelling techniques together can help characterise the condition of drinkers when using and leaving these settings. Here such methods identified patrons as routinely getting drunk, with risks of drunkenness

  3. Adaptive algebraic reconstruction technique

    International Nuclear Information System (INIS)

    Lu Wenkai; Yin Fangfang

    2004-01-01

    Algebraic reconstruction techniques (ART) are iterative procedures for reconstructing objects from their projections. It is proven that ART can be computationally efficient by carefully arranging the order in which the collected data are accessed during the reconstruction procedure and adaptively adjusting the relaxation parameters. In this paper, an adaptive algebraic reconstruction technique (AART), which adopts the same projection access scheme in multilevel scheme algebraic reconstruction technique (MLS-ART), is proposed. By introducing adaptive adjustment of the relaxation parameters during the reconstruction procedure, one-iteration AART can produce reconstructions with better quality, in comparison with one-iteration MLS-ART. Furthermore, AART outperforms MLS-ART with improved computational efficiency

  4. Resistance to the tetracyclines and macrolide-lincosamide-streptogramin group of antibiotics and its genetic linkage – a review

    Directory of Open Access Journals (Sweden)

    Durdica Marosevic

    2017-06-01

    Full Text Available An excessive use of antimicrobial agents poses a risk for the selection of resistant bacteria. Of particular interest are antibiotics that have large consumption rates in both veterinary and human medicine, such as the tetracyclines and macrolide-lincosamide-streptogramin (MLS group of antibiotics. A high load of these agents increases the risk of transmission of resistant bacteria and/or resistance determinants to humans, leading to a subsequent therapeutic failure. An increasing incidence of bacteria resistant to both tetracyclines and MLS antibiotics has been recently observed. This review summarizes the current knowledge on different tetracycline and MLS resistance genes that can be linked together on transposable elements.

  5. The Effect of Parenting Stress on Child Behavior Problems in High-Risk Children with Prenatal Drug Exposure

    Science.gov (United States)

    Bagner, Daniel M.; Sheinkopf, Stephen J.; Miller-Loncar, Cynthia; LaGasse, Linda L.; Lester, Barry M.; Liu, Jing; Bauer, Charles R.; Shankaran, Seetha; Bada, Henrietta; Das, Abhik

    2009-01-01

    Objective: To examine the relationship between early parenting stress and later child behavior in a high-risk sample and measure the effect of drug exposure on the relationship between parenting stress and child behavior. Methods: A subset of child-caregiver dyads (n = 607) were selected from the Maternal Lifestyle Study (MLS), which is a large…

  6. Magnetic design consideration of a Magnetic Lead Screw with Halbach Array

    DEFF Research Database (Denmark)

    Holm, Rasmus Koldborg; Berg, Nick Ilsø; Rasmussen, Peter Omand

    This paper presents the novel design of a Magnetic Lead Screw (MLS) with magnetic thread of Halbach Arrays. The MLS where designed and build, tests indicated a stall force which where 12 % lower than calculated in 3D FE. This is explained by demagnetization of the magnet during stall, the behavio...

  7. GenBank blastx search result: AK287540 [KOME

    Lifescience Database Archive (English)

    Full Text Available AK287540 J065011K01 AF013216.1 AF013216 Myxococcus xanthus Dog (dog), isocitrate lyase (icl), Mls (mls), Ufo... (ufo), fumarate hydratase (fhy), and proteosome major subunit (clpP) genes, complete cds; and acyl-CoA oxidase (aco) gene, partial cds. BCT 0.0 0 ...

  8. GenBank blastx search result: AK243510 [KOME

    Lifescience Database Archive (English)

    Full Text Available AK243510 J100075B22 AF013216.1 AF013216 Myxococcus xanthus Dog (dog), isocitrate lyase (icl), Mls (mls), Ufo... (ufo), fumarate hydratase (fhy), and proteosome major subunit (clpP) genes, complete cds; and acyl-CoA oxidase (aco) gene, partial cds. BCT 2e-87 1 ...

  9. GenBank blastx search result: AK243527 [KOME

    Lifescience Database Archive (English)

    Full Text Available AK243527 J100075P16 AF013216.1 AF013216 Myxococcus xanthus Dog (dog), isocitrate lyase (icl), Mls (mls), Ufo... (ufo), fumarate hydratase (fhy), and proteosome major subunit (clpP) genes, complete cds; and acyl-CoA oxidase (aco) gene, partial cds. BCT 1e-143 1 ...

  10. GenBank blastx search result: AK241214 [KOME

    Lifescience Database Archive (English)

    Full Text Available AK241214 J065122P06 AF013216.1 AF013216 Myxococcus xanthus Dog (dog), isocitrate lyase (icl), Mls (mls), Ufo... (ufo), fumarate hydratase (fhy), and proteosome major subunit (clpP) genes, complete cds; and acyl-CoA oxidase (aco) gene, partial cds. BCT 1e-151 1 ...

  11. Determination of the average lifetime of b-baryons

    CERN Document Server

    Abreu, P; Adye, T; Agasi, E; Ajinenko, I; Aleksan, Roy; Alekseev, G D; Alemany, R; Allport, P P; Almehed, S; Amaldi, Ugo; Amato, S; Andreazza, A; Andrieux, M L; Antilogus, P; Apel, W D; Arnoud, Y; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Bambade, P; Barão, F; Barate, R; Barbi, M S; Bardin, Dimitri Yuri; Baroncelli, A; Bärring, O; Barrio, J A; Bartl, Walter; Bates, M J; Battaglia, Marco; Baubillier, M; Baudot, J; Becks, K H; Begalli, M; Beillière, P; Belokopytov, Yu A; Belous, K S; Benvenuti, Alberto C; Berggren, M; Bertrand, D; Bianchi, F; Bigi, M; Bilenky, S M; Billoir, P; Bloch, D; Blume, M; Blyth, S; Bolognese, T; Bonesini, M; Bonivento, W; Booth, P S L; Borisov, G; Bosio, C; Bosworth, S; Botner, O; Boudinov, E; Bouquet, B; Bourdarios, C; Bowcock, T J V; Bozzo, M; Branchini, P; Brand, K D; Brenke, T; Brenner, R A; Bricman, C; Brillault, L; Brown, R C A; Brückman, P; Brunet, J M; Bugge, L; Buran, T; Burgsmüller, T; Buschmann, P; Buys, A; Cabrera, S; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Cankocak, K; Cao, F; Carena, F; Carroll, L; Caso, Carlo; Castillo-Gimenez, M V; Cattai, A; Cavallo, F R; Cerrito, L; Chabaud, V; Chapkin, M M; Charpentier, P; Chaussard, L; Chauveau, J; Checchia, P; Chelkov, G A; Chen, M; Chierici, R; Chliapnikov, P V; Chochula, P; Chorowicz, V; Chudoba, J; Cindro, V; Collins, P; Contreras, J L; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Crawley, H B; Crennell, D J; Crosetti, G; Cuevas-Maestro, J; Czellar, S; Dahl-Jensen, Erik; Dahm, J; D'Almagne, B; Dam, M; Damgaard, G; Dauncey, P D; Davenport, Martyn; Da Silva, W; Defoix, C; Deghorain, A; Della Ricca, G; Delpierre, P A; Demaria, N; De Angelis, A; de Boer, Wim; De Brabandere, S; De Clercq, C; La Vaissière, C de; De Lotto, B; De Min, A; De Paula, L S; De Saint-Jean, C; Dijkstra, H; Di Ciaccio, Lucia; Djama, F; Dolbeau, J; Dönszelmann, M; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Dufour, Y; Edsall, D M; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, Gösta; Elsing, M; Engel, J P; Ershaidat, N; Erzen, B; Falk, E; Fassouliotis, D; Feindt, Michael; Ferrer, A; Filippas-Tassos, A; Firestone, A; Fischer, P A; Föth, H; Fokitis, E; Fontanelli, F; Formenti, F; Franek, B J; Frenkiel, P; Fries, D E C; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fuster, J A; Galloni, A; Gamba, D; Gandelman, M; García, C; García, J; Gaspar, C; Gasparini, U; Gavillet, P; Gazis, E N; Gelé, D; Gerber, J P; Gerdyukov, L N; Gibbs, M; Gokieli, R; Golob, B; Gopal, Gian P; Gorn, L; Górski, M; Guz, Yu; Gracco, Valerio; Graziani, E; Grosdidier, G; Grzelak, K; Gumenyuk, S A; Gunnarsson, P; Günther, M; Guy, J; Hahn, F; Hahn, S; Hajduk, Z; Hallgren, A; Hamacher, K; Hao, W; Harris, F J; Hedberg, V; Henriques, R P; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Higón, E; Hilke, Hans Jürgen; Hill, T S; Holmgren, S O; Holt, P J; Holthuizen, D J; Hoorelbeke, S; Houlden, M A; Hrubec, Josef; Huet, K; Hultqvist, K; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, C; Jarlskog, G; Jarry, P; Jean-Marie, B; Johansson, E K; Jönsson, L B; Jönsson, P E; Joram, Christian; Juillot, P; Kaiser, M; Kapusta, F; Karafasoulis, K; Karlsson, M; Karvelas, E; Katsanevas, S; Katsoufis, E C; Keränen, R; Khokhlov, Yu A; Khomenko, B A; Khovanskii, N N; King, B J; Kjaer, N J; Klein, H; Klovning, A; Kluit, P M; Köne, B; Kokkinias, P; Koratzinos, M; Korcyl, K; Kourkoumelis, C; Kuznetsov, O; Kramer, P H; Krammer, Manfred; Kreuter, C; Kronkvist, I J; Krumshtein, Z; Krupinski, W; Kubinec, P; Kucewicz, W; Kurvinen, K L; Lacasta, C; Laktineh, I; Lamblot, S; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Last, I; Laugier, J P; Lauhakangas, R; Leder, Gerhard; Ledroit, F; Lefébure, V; Legan, C K; Leitner, R; Lemoigne, Y; Lemonne, J; Lenzen, Georg; Lepeltier, V; Lesiak, T; Liko, D; Lindner, R; Lipniacka, A; Lippi, I; Lörstad, B; Loken, J G; López, J M; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J N; Maehlum, G; Maio, A; Malychev, V; Mandl, F; Marco, J; Marco, R P; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Maron, T; Martínez-Rivero, C; Martínez-Vidal, F; Martí i García, S; Masik, J; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, M; McCubbin, M L; McKay, R; McNulty, R; Medbo, J; Merk, M; Meroni, C; Meyer, S; Meyer, W T; Michelotto, M; Migliore, E; Mirabito, L; Mitaroff, Winfried A; Mjörnmark, U; Moa, T; Møller, R; Mönig, K; Monge, M R; Morettini, P; Müller, H; Mundim, L M; Murray, W J; Muryn, B; Myatt, Gerald; Naraghi, F; Navarria, Francesco Luigi; Navas, S; Nawrocki, K; Negri, P; Némécek, S; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Nikolaenko, V; Niss, P; Nomerotski, A; Normand, Ainsley; Oberschulte-Beckmann, W; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, Risto; Österberg, K; Ouraou, A; Paganini, P; Paganoni, M; Pagès, P; Palka, H; Papadopoulou, T D; Papageorgiou, K; Pape, L; Parkes, C; Parodi, F; Passeri, A; Pegoraro, M; Peralta, L; Pernegger, H; Perrotta, A; Petridou, C; Petrolini, A; Petrovykh, M; Phillips, H T; Piana, G; Pierre, F; Pimenta, M; Pindo, M; Plaszczynski, S; Podobrin, O; Pol, M E; Polok, G; Poropat, P; Pozdnyakov, V; Prest, M; Privitera, P; Pukhaeva, N; Pullia, Antonio; Radojicic, D; Ragazzi, S; Rahmani, H; Ratoff, P N; Read, A L; Reale, M; Rebecchi, P; Redaelli, N G; Regler, Meinhard; Reid, D; Renton, P B; Resvanis, L K; Richard, F; Richardson, J; Rídky, J; Rinaudo, G; Ripp, I; Romero, A; Roncagliolo, I; Ronchese, P; Roos, L; Rosenberg, E I; Rosso, E; Roudeau, Patrick; Rovelli, T; Rückstuhl, W; Ruhlmann-Kleider, V; Ruiz, A; Rybicki, K; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sajot, G; Salt, J; Sánchez, J; Sannino, M; Schimmelpfennig, M; Schneider, H; Schwickerath, U; Schyns, M A E; Sciolla, G; Scuri, F; Seager, P; Sedykh, Yu; Segar, A M; Seitz, A; Sekulin, R L; Shellard, R C; Siccama, I; Siegrist, P; Simonetti, S; Simonetto, F; Sissakian, A N; Sitár, B; Skaali, T B; Smadja, G; Smirnov, N; Smirnova, O G; Smith, G R; Solovyanov, O; Sosnowski, R; Souza-Santos, D; Spassoff, Tz; Spiriti, E; Sponholz, P; Squarcia, S; Stanescu, C; Stapnes, Steinar; Stavitski, I; Stichelbaut, F; Stocchi, A; Strauss, J; Strub, R; Stugu, B; Szczekowski, M; Szeptycka, M; Tabarelli de Fatis, T; Tavernet, J P; Chikilev, O G; Tilquin, A; Timmermans, J; Tkatchev, L G; Todorov, T; Toet, D Z; Tomaradze, A G; Tomé, B; Tonazzo, A; Tortora, L; Tranströmer, G; Treille, D; Trischuk, W; Tristram, G; Trombini, A; Troncon, C; Tsirou, A L; Turluer, M L; Tyapkin, I A; Tyndel, M; Tzamarias, S; Überschär, B; Ullaland, O; Uvarov, V; Valenti, G; Vallazza, E; Van der Velde, C; van Apeldoorn, G W; van Dam, P; Van Doninck, W K; Van Eldik, J; Vassilopoulos, N; Vegni, G; Ventura, L; Venus, W A; Verbeure, F; Verlato, M; Vertogradov, L S; Vilanova, D; Vincent, P; Vitale, L; Vlasov, E; Vodopyanov, A S; Vrba, V; Wahlen, H; Walck, C; Waldner, F; Weierstall, M; Weilhammer, Peter; Weiser, C; Wetherell, Alan M; Wicke, D; Wickens, J H; Wielers, M; Wilkinson, G R; Williams, W S C; Winter, M; Witek, M; Woschnagg, K; Yip, K; Yushchenko, O P; Zach, F; Zaitsev, A; Zalewska-Bak, A; Zalewski, Piotr; Zavrtanik, D; Zevgolatakos, E; Zimin, N I; Zito, M; Zontar, D; Zuberi, R; Zucchelli, G C; Zumerle, G; Belokopytov, Yu; Charpentier, Ph; Gavillet, Ph; Gouz, Yu; Jarlskog, Ch; Khokhlov, Yu; Papadopoulou, Th D

    1996-01-01

    The average lifetime of b-baryons has been studied using 3 \\times 10^6 hadronic Z^0 decays collected by the DELPHI detector at LEP. Three methods have been used, based on the measurement of different observables: the proper decay time distribution of 206 vertices reconstructed with a \\Lambda, a lepton and an oppositely charged pion; the impact parameter distribution of 441 muons with high transverse momentum accompanied by a \\mLs in the same jet; and the proper decay time distribution of 125 \\Lambda_c-lepton decay vertices with the \\Lambda_c exclusively reconstructed through its pK\\pi, pK^0 and \\mLs3\\pi decay modes. The combined result is~:\\par \\begin{center} \\tau(b-baryon) = (1.25^{+0.13}_{-0.11}\\ pm0.04(syst)^{+0.03}_{-0. 05}(syst)) ps\\par \\end{center} where the first systematic error is due to experimental uncertainties and the second to the uncertainties in the modelling of the b-baryon production and semi-leptonic decay. Including the measurement recently published by DELPHI based on a sample of proton-m...

  12. Fabrication of Hadfield-Cored Multi-layer Steel Sheet by Roll-Bonding with 1.8-GPa-Strength-Grade Hot-Press-Forming Steel

    Science.gov (United States)

    Chin, Kwang-Geun; Kang, Chung-Yun; Park, Jaeyeong; Lee, Sunghak

    2018-05-01

    An austenitic Hadfield steel was roll-bonded with a 1.8-GPa-strength-grade martensitic hot-press-forming (HPF) steel to fabricate a multi-layer steel (MLS) sheet. Near the Hadfield/HPF interface, the carburized and decarburized layers were formed by the carbon diffusion from the Hadfield (1.2%C) to HPF (0.35%C) layers, and could be regarded as kinds of very thin multi-layers of 35 μm in thickness. The tensile test and fractographic data indicated that the MLS sheet was fractured abruptly within the elastic range by the intergranular fracture occurred in the carburized layer. This was because C was mainly segregated at prior austenite grain boundaries in the carburized layer, which weakened grain boundaries to induce the intergranular fracture. In order to solve the intergranular facture problem, the MLS sheet was tempered at 200 °C. The stress-strain curve of the tempered MLS sheet lay between those of the HPF and Hadfield sheets, and a rule of mixtures was roughly satisfied. Tensile properties of the MLS sheet were dramatically improved after the tempering, and the intergranular fracture was erased completely. In particular, the yield strength up to 1073 MPa along with the high strain hardening and excellent ductility of 32.4% were outstanding because the yield strength over 1 GPa was hardly achieved in conventional austenitic steels.

  13. GenBank blastn search result: AK241214 [KOME

    Lifescience Database Archive (English)

    Full Text Available AK241214 J065122P06 AF013216.1 AF013216 Myxococcus xanthus Dog (dog), isocitrate lyase (icl), Mls (mls), Ufo... (ufo), fumarate hydratase (fhy), and proteosome major subunit (clpP) genes, complete cds; and acyl-CoA oxidase (aco) gene, partial cds. BCT 8e-18 1 -1 ...

  14. Serum Copper Level Significantly Influences Platelet Count, Lymphocyte Count and Mean Cell Hemoglobin in Sickle Cell Anemia

    Directory of Open Access Journals (Sweden)

    Okocha Chide

    2015-12-01

    Full Text Available Background Changes in serum micro nutrients levels affect a number of critically important metabolic processes; these could potentially influence blood counts and ultimately disease presentation in patients with sickle cell anemia (SCA. Objectives To evaluate the influence of serum micro-nutrients levels; zinc, copper, selenium and magnesium on blood counts in steady state SCA patients. Methods A cross sectional study that involved 28 steady state adult SCA subjects. Seven milliliters (mls of blood was collected; 3 mls was for hemoglobin electrophoresis and full blood count determination while 4 mls was for measurement of serum micro nutrients levels, by the atomic absorption spectrophotometry. Correlation between serum micro-nutrient levels and blood counts was done by the Pearson’s linear regression. Ethical approval was obtained from the institutional review board and each participant gave informed consent. All data was analyzed by SPSS software version 20. Results There was a significant correlation between serum copper levels and mean cell hemoglobin (MCH, platelet and lymphocyte counts (r = 0.418; P = 0.02, r = -0.376; P = 0.04 and r = -0.383; P = 0.04, respectively. There were no significant correlations between serum levels of other micro nutrients (selenium, zinc and magnesium and blood counts. Conclusions Copper influences blood count in SCA patients probably by inducing red cell haemolysis, oxidant tissue damage and stimulating the immune system.

  15. A Least Squares Collocation Method for Accuracy Improvement of Mobile LiDAR Systems

    Directory of Open Access Journals (Sweden)

    Qingzhou Mao

    2015-06-01

    Full Text Available In environments that are hostile to Global Navigation Satellites Systems (GNSS, the precision achieved by a mobile light detection and ranging (LiDAR system (MLS can deteriorate into the sub-meter or even the meter range due to errors in the positioning and orientation system (POS. This paper proposes a novel least squares collocation (LSC-based method to improve the accuracy of the MLS in these hostile environments. Through a thorough consideration of the characteristics of POS errors, the proposed LSC-based method effectively corrects these errors using LiDAR control points, thereby improving the accuracy of the MLS. This method is also applied to the calibration of misalignment between the laser scanner and the POS. Several datasets from different scenarios have been adopted in order to evaluate the effectiveness of the proposed method. The results from experiments indicate that this method would represent a significant improvement in terms of the accuracy of the MLS in environments that are essentially hostile to GNSS and is also effective regarding the calibration of misalignment.

  16. Ecological approach of macrolide-lincosamides-streptogramin producing actinomyces from Cuban soils.

    Science.gov (United States)

    González, I; Niebla, A; Lemus, M; González, L; Iznaga, I O; Pérez, M E; Vallin, C

    1999-09-01

    We report in this study the frequency of Streptomyces strains to produce macrolide-lincosamide-streptogramin (MLS) antibiotics isolated from Cuban soils. The screening assay is based on the induction of MLS-resistance phenotype in a clinical isolated strain of Staphylococcus aureus S-18. Our results suggest that of 800 Streptomyces strains isolated from different soil samples, 6% were positives in the screening test used. The ferralitic red soil from Pinar del Río (north) provided the major percentage (3.6%) of MLS producing strains. The other soil samples tested belonging to Guira de Melena and Bauta in Havana, Matanzas City, Topes De Collantes (Villa Clara), and Soroa Mountains (Pinar del Rio) hill reached very low percentages.

  17. Evaluation of higher brain function by MRI. Flow measurement in the superior sagittal sinus using phase contrast method

    International Nuclear Information System (INIS)

    Ono, Mototsugu

    1997-01-01

    To assess the higher brain function, flow measurement in the superior sagittal sinus (SSS) was performed noninvasively using a phase contrast MRI in 76 patients with suspicious of impaired higher brain function including dementias (senile dementia of Alzheimer type; SDAT and multi-infarct dementia; MID), strokes, and others. Thirty-one normal controls were consisted of 18 healthy volunteers and 13 patients with tension headache whose higher brain function was proved be normal. Mean flow velocity was measured in the distal portion of the SSS adjoining to the occipital lobes and was multiplied by cross-sectional area of the SSS at the measuring point to obtain mean flow volume. For intellectual index, cross-cultural cognitive examination (CCCE) was applied to all cases excluding volunteers. Normal value of SSS flow volume measured by MRI was 6.92±0.66 ml/s. Significant differences in both SSS flow and CCCE score from normal controls were found in SDAT group, MID group, and non-dementia group. No substantial differences between SDAT group and MID group were noted in both CCCE score and SSS flow. In normal controls, there was no correlation between SSS flow and age, whereas, significant inverse correlation of SSS flow with age was found in all cases. Between CCCE score and SSS flow, there were nearly linear relationships in all cases, SDAT group, MID group, and non-dementia group. Significant but relatively poor correlation was found in normals. (K.H.)

  18. 75 FR 62923 - WRC-07 Table Clean-up Order

    Science.gov (United States)

    2010-10-13

    ... service (MSS) allocations to earth stations operating with non-Federal space stations) to the bottom of....522C, and 5.549) so that it fully comports with the ITU Radio Regulations; capitalize ``Earth'' in RR 5... landing system or MLS) take precedence over other uses of this band. WRC-07 revised RR 5.444 such that MLS...

  19. Evaluation of the InnoTyper® 21 genotyping kit in multi-ethnic populations

    DEFF Research Database (Denmark)

    Ristow, Peter Gustav; Barnes, Nicole; Murphy, Gina Pineda

    2017-01-01

    We report the findings of the evaluation of the InnoTyper® 21 genotyping kit for the use of human identification (HID) and paternity testing in South Africa. This novel forensic kit evaluates 20 retrotransposable elements (AC4027, MLS26, ALU79712, NBC216, NBC106, RG148, NBC13, AC2265, MLS09, AC11...

  20. Idiopathic pericardial effusion in 2 year old labrador managed with ...

    African Journals Online (AJOL)

    Ultrasound-guided pericardiocentesis was carried out using a 16 gauge over the needle catheter attached to a 3-way stopcock and a 20mls syringe; about 65mls of clear effusate was aspirated. Laboratory analysis of the effusate revealed that it was a transudate. The patient was placed on 3mg/kg furosemide, twice daily for ...

  1. Revisit Of Current Patterns Of Semen Quality Among Male Partners ...

    African Journals Online (AJOL)

    About 61% of the patients produced semen by coitus interruptus while, 34.3% obtained their samples by masturbation. Majority of the patients (70.1%) produced semen volume of greater than 2mls, while 29.9% produced semen of less than 2mls. Of the total number, 34.7% were normozoospermia while, 65.3% had one ...

  2. Adverse events and therapeutic efficacy associated with TACE for hepatocellular carcinoma with a miriplatin-lipiodol suspension in comparison with a cisplatin-lipiodol suspension

    International Nuclear Information System (INIS)

    Araki, Takuji; Okada, Taiki; Kimura, Kazufumi; Sawada, Eiichi; Sano, Katushiro; Araki, Tsutomu

    2012-01-01

    The aim of this study was to evaluate the short-term adverse events and therapeutic efficacy of transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) with a miriplatin-lipiodol suspension in comparison with a cisplatin-lipiodol suspension. Of patients who underwent TACE for unresectable HCCs in 2009 and 2010, twenty-nine and twenty-seven patients underwent TACE using cisplatin-lipiodol suspension (C-LS) and miriplatin-lipiodol suspension (M-LS), respectively. Adverse events of fever, pain, nausea, anorexia, elevation of aspartate aminotransferase (AST), total bilirubin, creatinine and a decrease in platelet count were evaluated by the National Cancer Institute Common Toxicity Criteria Ver.4. to compare the C-LS and M-LS groups. The short-term therapeutic efficacy of both groups was evaluated by the treatment effect (TE) on the CT images three months after TACE according to the General Rules for the Clinical and Pathological Study of Primary Liver Cancer (the 5th edition, Revised Version). With regard to the adverse events, the M-LS group had significantly less fever and anorexia than the C-LS group. No critical adverse events were observed in either group. The therapeutic efficacy was not significantly different between the groups. TACE with M-LS had fewer adverse events than TACE with C-LS, but neither TACE led to any critical adverse events. The short-term therapeutic efficacy of TACE with M-LS was equivalent to that of TACE with C-LS. (author)

  3. Fine-needle percutaneous transhepatic parenchymal portal venography by using carbon dioxide: a pilot study in pigs

    International Nuclear Information System (INIS)

    Sun, Fei; Hernandez, Javier; Crisostomo, Veronica; Pineda, Luis-Fernando; Lima, Juan Rafael; Uson, Jesus; Maynar, Manuel

    2003-01-01

    Our purpose was to evaluate the feasibility and safety of carbon dioxide (CO 2 ) in fine-needle percutaneous transhepatic parenchymal portal venography and its potential clinical applications. Three Belgian landrace pigs received fine-needle percutaneous transhepatic parenchymal portal venography by using CO 2 as a contrast agent. Under fluoroscopic and B-mode ultrasonic guidance, right or left lobe of liver was punctured with a 22-G Chiba needle, through which CO 2 was injected with a dedicated CO 2 injector at injection rate of 20 ml/s for 20 ml, 40 ml/s for 40 ml, 40 ml/s for 60 ml, and 40 ml/s for 80 ml, respectively. The portal venograms were obtained by use of digital subtraction angiography (DSA) system with animal in supine position. In one pig transarterial portal venography was performed, in addition, using iodinated contrast agent. The portal vein was visualized in each run of venography. Optimal images of portal tree structure up to four-order branches were obtained in all those with CO 2 injection rate of 40 ml/s, which appeared much better in quality than those obtained by cranial mesenteric arteriography with iodinated contrast agent. No extravasation of CO 2 , liver laceration, or any other complication occurred during the procedures. The technique we proposed demonstrated optimal portography, which appeared to be safe, minimally invasive, less time-consuming, cost-effective, and easy to perform, with great potential in clinical applications. (orig.)

  4. Prevalence of Genotypes That Determine Resistance of Staphylococci to Macrolides and Lincosamides in Serbia

    Directory of Open Access Journals (Sweden)

    Milena Mišić

    2017-08-01

    Full Text Available Macrolides, lincosamides, and streptogramins (MLS resistance genes are responsible for resistance to these antibiotics in Staphylococcus infections. The purpose of the study was to analyze the distribution of the MLS resistance genes in community- and hospital-acquired Staphylococcus isolates. The MLS resistance phenotypes [constitutive resistance to macrolide–lincosamide–streptogramin B (cMLSb, inducible resistance to macrolide–lincosamide–streptogramin B (iMLSb, resistance to macrolide/macrolide–streptogramin B (M/MSb, and resistance to lincosamide–streptogramin A/streptogramin B (LSa/b] were determined by double-disc diffusion method. The presence of the MLS resistance genes (ermA, ermB, ermC, msrA/B, lnuA, lnuB, and lsaA were determined by end-point polymerase chain reaction in 179 isolates of staphylococci collected during 1-year period at the Center for Microbiology of Public Health Institute in Vranje. The most frequent MLS phenotype among staphylococcal isolates, both community-acquired and hospital-acquired, was iMLSb (33.4%. The second most frequent was M/MSb (17.6% with statistically significantly higher number of hospital-acquired staphylococcal isolates (p < 0.05. MLS resistance was mostly determined by the presence of msrA/B (35.0% and ermC (20.8% genes. Examined phenotypes were mostly determined by the presence of one gene, especially by msrA/B (26.3% and ermC (14.5%, but 15.6% was determined by a combination of two or more genes. M/MSb phenotype was the most frequently encoded by msrA/B (95.6% gene, LSa/b phenotype by lnuA (56.3% gene, and iMLSb phenotype by ermC (29.4% and ermA (25.5% genes. Although cMLSb phenotype was mostly determined by the presence of ermC (28.9%, combinations of two or more genes have been present too. This pattern was particularly recorded in methicillin-resistant Staphylococcus aureus (MRSA (58.3% and methicillin-resistant coagulase-negative staphylococci (MRCNS (90.9% isolates with c

  5. UARS PEM Level 2 MEPS V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The Particle Environment Monitor (PEM) level 2 Medium-Energy Particle Spectrometer (MEPS) daily product contains the electron and proton high-resolution spectral...

  6. Pramana – Journal of Physics | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    We calculate the longitudinal ultrasonic attenuation rate (UAR) in clean d-wave superconductors in the Meissner and the mixed phases. In the Meissner phase we calculate the contribution of previously ignored processes involving the excitation of a pair of quasi-holes or quasi-particles. There is a contribution ∝ in the ...

  7. Qanun raqam 68 li-sanat 1968 fi sha'n al-ta'lim al-am (Law No. 68 of 1968 Concerning General Education).

    Science.gov (United States)

    United Arab Republic.

    This document is an English-language abstract (approximately 1,500 words) of a law passed by the UAR legislation covering elementary, preparatory, and secondary education. This law covers general regulations common to all three stages of education, the objectives of which are defined as the general intellectual, physical, moral, civic and national…

  8. A Novel Stretch Sensor to Measure Venous Hemodynamics

    Directory of Open Access Journals (Sweden)

    Syrpailyne Wankhar

    2018-07-01

    Full Text Available Chronic venous insufficiency is a debilitating condition causing varicose veins and venous ulcers. The pathophysiology includes reflux and venous obstruction. The diagnosis is often made by clinical examination and confirmed by Venous Doppler studies. Plethysmography helps to quantitatively examine the reflux and diagnose the burden of deep venous pathology to better understand venous hemodynamics, which is not elicited by venous duplex examination alone. However, most of these tests are qualitative, expensive, and not easily available. In this paper, we demonstrate the potential use of a novel stretch sensor in the assessment of venous hemodynamics during different maneuvers by measuring the change in calf circumference. We designed the stretch sensor by using semiconductor strain gauges pasted onto a small metal bar to form a load cell. The elastic and Velcro material attached to the load cell form a belt. It converts the change in limb circumference to a proportional tension (force of distension when placed around the calf muscle. We recorded the change in limb circumference from arrays of stretch sensors by using an in-house data acquisition system. We calculated the venous volume (VV, venous filling index (VFI, ejection fraction (EF and residual venous volume (RVV on two normal subjects and on two patients to assess venous hemodynamics. The values (VV > 60 ml, VFI 60%, RVV 2ml/s, EF 35% in patients were comparable to those reported in the literature.

  9. Remote sensing of atmospheric chemistry; Proceedings of the Meeting, Orlando, FL, Apr. 1-3, 1991

    Science.gov (United States)

    McElroy, James L.; McNeal, Robert J.

    The present volume on remote sensing of atmospheric chemistry discusses special remote sensing space observations and field experiments to study chemical change in the atmosphere, network monitoring for detection of stratospheric chemical change, stratospheric chemistry studies, and the combining of model, in situ, and remote sensing in atmospheric chemistry. Attention is given to the measurement of tropospheric carbon monoxide using gas filter radiometers, long-path differential absorption measurements of tropospheric molecules, air quality monitoring with the differential optical absorption spectrometer, and a characterization of tropospheric methane through space-based remote sensing. Topics addressed include microwave limb sounder experiments for UARS and EOS, an overview of the spectroscopy of the atmosphere using an FIR emission experiment, the detection of stratospheric ozone trends by ground-based microwave observations, and a FIR Fabry-Perot spectrometer for OH measurements. (For individual items see A93-31377 to A93-31412)

  10. Contrast-enhanced magnetic resonance angiography: first-pass arterial enhancement as a function of gadolinium-chelate concentration, and the saline chaser volume and injection rate.

    Science.gov (United States)

    Husarik, Daniela B; Bashir, Mustafa R; Weber, Paul W; Nichols, Eli B; Howle, Laurens E; Merkle, Elmar M; Nelson, Rendon C

    2012-02-01

    To evaluate the effect of the contrast medium (CM) concentration and the saline chaser volume and injection rate on first-pass aortic enhancement characteristics in contrast-enhanced magnetic resonance angiography using a physiologic flow phantom. Imaging was performed on a 3.0-T magnetic resonance system (MAGNETOM Trio, Siemens Healthcare Solutions, Inc, Erlangen, Germany) using a 2-dimensional fast low angle shot T1-weighted sequence (repetition time, 500 milliseconds; echo time, 1.23 milliseconds; flip angle, 8 degrees; 1 frame/s × 60 seconds). The following CM concentrations injected at 2 mL/s were used with 3 different contrast agents (gadolinium [Gd]-BOPTA, Gd-HP-DO3A, Gd-DTPA): 20 mL of undiluted CM (100%) and 80%, 40%, 20%, 10%, 5%, and 2.5% of the full amount, all diluted in saline to a volume of 20 mL to ensure equal bolus volume. The CM was followed by saline chasers of 20 to 60 mL injected at 2 mL/s and 6 mL/s. Aortic signal intensity (SI) was measured, and normalized SI versus time (SI/Tn) curves were generated. The maximal SI (SI(max)), bolus length, and areas under the SI/Tn curve were calculated. Decreasing the CM concentration from 100% to 40% resulted in a decrease of SI(max) to 86.1% (mean). Further decreasing the CM concentration to 2.5% decreased SI(max) to 5.1% (mean). Altering the saline chaser volume had no significant effect on SI(max). Increasing the saline chaser injection rate had little effect (mean increase, 2.2%) on SI(max) when using ≥40% of CM. There was a larger effect (mean increase, 19.6%) when ≤20% of CM were used. Bolus time length was significantly shorter (P < 0.001), and area under the SI/T(n) curve was significantly smaller (P < 0.01) for the CM protocols followed by a saline chaser injected at 6 mL/s compared with a saline chaser injected at 2 mL/s. With 40% of CM and a fast saline chaser, SImax close to that with undiluted CM can be achieved. An increased saline chaser injection rate has a more pronounced effect on

  11. Tatwir al-ta'lim al-sina'i fi al-Jumhurriyah al-'arabiyah al-Muttahidah (Development of Industrial Education in the United Arab Republic).

    Science.gov (United States)

    Ministry of Education, Cairo (United Arab Republic).

    This document is an English-language abstract (approximately 1,500 words) of a publication giving the steps to be taken to develop industrial education to conform to the socialist economic planning in the UAR. It is divided into eight sections dealing with various aspects of development: (1) curricula of technical schools; (2) general description…

  12. Interference Suppression Performance of Automotive UWB Radars Using Pseudo Random Sequences

    Directory of Open Access Journals (Sweden)

    I. Pasya

    2015-12-01

    Full Text Available Ultra wideband (UWB automotive radars have attracted attention from the viewpoint of reducing traffic accidents. The performance of automotive radars may be degraded by interference from nearby radars using the same frequency. In this study, a scenario where two cars pass each other on a road was considered. Considering the utilization of cross-polarization, the desired-to-undesired signal power ratio (DUR was found to vary approximately from -10 to 30 dB. Different pseudo random sequences were employed for spectrum spreading the different radar signals to mitigate the interference effects. This paper evaluates the interference suppression provided by maximum length sequence (MLS and Gold sequence (GS through numerical simulations of the radar’s performance in terms of probability of false alarm and probability of detection. It was found that MLS and GS yielded nearly the same performance when the DUR is -10 dB (worst case; for example when fixing the probability of false alarm to 0.0001, the probabilities of detection were 0.964 and 0.946 respectively. The GS are more advantageous than MLS due to larger number of different sequences having the same length in GS than in MLS.

  13. Effect of flattened surface morphology of anodized aluminum oxide templates on the magnetic properties of nanoporous Co/Pt and Co/Pd thin multilayered films

    Science.gov (United States)

    Nguyen, T. N. Anh; Fedotova, J.; Kasiuk, J.; Bayev, V.; Kupreeva, O.; Lazarouk, S.; Manh, D. H.; Vu, D. L.; Chung, S.; Åkerman, J.; Altynov, V.; Maximenko, A.

    2018-01-01

    For the first time, nanoporous Al2O3 templates with smoothed surface relief characterized by flattened interpore areas were used in the fabrication of Co/Pd and Co/Pt multilayers (MLs) with strong perpendicular magnetic anisotropy (PMA). Alternating gradient magnetometry (AGM) revealed perfectly conserved PMA in the Co/Pd and Co/Pt porous MLs (antidot arrays) with a ratio of remanent magnetization (Mr) to saturation magnetization (MS) of about 0.99, anisotropy fields (Ha) of up to 2.6 kOe, and a small deviation angle of 8° between the easy magnetization axis and the normal to the film surface. The sufficient magnetic hardening of the porous MLs with enhanced coercive field HC of up to ∼1.9 kOe for Co/Pd and ∼1.5 kOe for Co/Pt MLs, as compared to the continuous reference samples (∼1.5-2 times), is associated with the pinning of the magnetic moments on the nanopore edges. Application of the Stoner-Wohlfarth model for fitting the experimental M/MS(H) curves yielded clear evidence of the predominantly coherent rotation mechanism of magnetization reversal in the porous films.

  14. Terminal structures of West Nile virus genomic RNA and their interactions with viral NS5 protein

    International Nuclear Information System (INIS)

    Dong Hongping; Zhang Bo; Shi Peiyong

    2008-01-01

    Genome cyclization is essential for flavivirus replication. We used RNases to probe the structures formed by the 5'-terminal 190 nucleotides and the 3'-terminal 111 nucleotides of the West Nile virus (WNV) genomic RNA. When analyzed individually, the two RNAs adopt stem-loop structures as predicted by the thermodynamic-folding program. However, when mixed together, the two RNAs form a duplex that is mediated through base-pairings of two sets of RNA elements (5'CS/3'CSI and 5'UAR/3'UAR). Formation of the RNA duplex facilitates a conformational change that leaves the 3'-terminal nucleotides of the genome (position - 8 to - 16) to be single-stranded. Viral NS5 binds specifically to the 5'-terminal stem-loop (SL1) of the genomic RNA. The 5'SL1 RNA structure is essential for WNV replication. The study has provided further evidence to suggest that flavivirus genome cyclization and NS5/5'SL1 RNA interaction facilitate NS5 binding to the 3' end of the genome for the initiation of viral minus-strand RNA synthesis

  15. A prospective study of lung function among boilermaker construction workers exposed to combustion particulates

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, R.; Eisen, E.A.; Pothier, L.; Christiani, D.C. [Harvard University, Boston, MA (USA). School of Public Health, Occupational Health Program, Dept. of Environmental Health

    2001-05-01

    As part of an ongoing investigation, a 2-year longitudinal study of lung function among 118 boilermakers was conducted. Exposure was assessed with a work history questionnaire. Spirometry measurements were performed annually. Results show an association between annual FEV1 and hours worked at a gas-fired plant during the previous year, beta = -9.8 mls/100 hours worked (85% CI:-16.0,-3.5) after adjustment for age, baseline FEV1 and cigarette smoking status. The adjusted association between FEV1 and 'ever' worked at a gas-fired plant was -99.7 mls (95% CI: -154.8, -44.5). There was also evidence of a negative association between FEV1 and 'ever' worked and hours worked at oil and coal-fired plants. These data suggest an association between annual lung function loss and working at gas, coal and oil-fired plants. Further follow-up of this cohort of boilermakers is in progress.

  16. Automatic Detection and Classification of Pole-Like Objects for Urban Cartography Using Mobile Laser Scanning Data

    Directory of Open Access Journals (Sweden)

    Celestino Ordóñez

    2017-06-01

    Full Text Available Mobile laser scanning (MLS is a modern and powerful technology capable of obtaining massive point clouds of objects in a short period of time. Although this technology is nowadays being widely applied in urban cartography and 3D city modelling, it has some drawbacks that need to be avoided in order to strengthen it. One of the most important shortcomings of MLS data is concerned with the fact that it provides an unstructured dataset whose processing is very time-consuming. Consequently, there is a growing interest in developing algorithms for the automatic extraction of useful information from MLS point clouds. This work is focused on establishing a methodology and developing an algorithm to detect pole-like objects and classify them into several categories using MLS datasets. The developed procedure starts with the discretization of the point cloud by means of a voxelization, in order to simplify and reduce the processing time in the segmentation process. In turn, a heuristic segmentation algorithm was developed to detect pole-like objects in the MLS point cloud. Finally, two supervised classification algorithms, linear discriminant analysis and support vector machines, were used to distinguish between the different types of poles in the point cloud. The predictors are the principal component eigenvalues obtained from the Cartesian coordinates of the laser points, the range of the Z coordinate, and some shape-related indexes. The performance of the method was tested in an urban area with 123 poles of different categories. Very encouraging results were obtained, since the accuracy rate was over 90%.

  17. A Review on the Toxicity and Non-Target Effects of Macrocyclic Lactones in Terrestrial and Aquatic Environments

    Science.gov (United States)

    Lumaret, Jean-Pierre; Errouissi, Faiek; Floate, Kevin; Römbke, Jörg; Wardhaugh, Keith

    2012-01-01

    The avermectins, milbemycins and spinosyns are collectively referred to as macrocyclic lactones (MLs) which comprise several classes of chemicals derived from cultures of soil micro-organisms. These compounds are extensively and increasingly used in veterinary medicine and agriculture. Due to their potential effects on non-target organisms, large amounts of information on their impact in the environment has been compiled in recent years, mainly caused by legal requirements related to their marketing authorization or registration. The main objective of this paper is to critically review the present knowledge about the acute and chronic ecotoxicological effects of MLs on organisms, mainly invertebrates, in the terrestrial and aquatic environment. Detailed information is presented on the mode-of-action as well as the ecotoxicity of the most important compounds representing the three groups of MLs. This information, based on more than 360 references, is mainly provided in nine tables, presenting the effects of abamectin, ivermectin, eprinomectin, doramectin, emamectin, moxidectin, and spinosad on individual species of terrestrial and aquatic invertebrates as well as plants and algae. Since dung dwelling organisms are particularly important non-targets, as they are exposed via dung from treated animals over their whole life-cycle, the information on the effects of MLs on dung communities is compiled in an additional table. The results of this review clearly demonstrate that regarding environmental impacts many macrocyclic lactones are substances of high concern particularly with larval instars of invertebrates. Recent studies have also shown that susceptibility varies with life cycle stage and impacts can be mitigated by using MLs when these stages are not present. However information on the environmental impact of the MLs is scattered across a wide range of specialised scientific journals with research focusing mainly on ivermectin and to a lesser extent on abamectin

  18. 31P nuclear magnetic resonance spectroscopy studies of tumor energy metabolism and its relationship to intracapillary oxyhemoglobin saturation status and tumor hypoxia.

    Science.gov (United States)

    Rofstad, E K; DeMuth, P; Fenton, B M; Sutherland, R M

    1988-10-01

    Relationships between tumor bioenergetic status on the one hand and intracapillary oxyhemoglobin (HbO2) saturation status and fraction of radiobiologically hypoxic cells on the other were studied using two murine sarcoma lines (KHT, RIF-1) and two human ovarian carcinoma xenograft lines (MLS, OWI). Tumor energy metabolism was studied in vivo by 31P nuclear magnetic resonance (NMR) spectroscopy and the resonance area ratio (PCr + NTP beta)/Pi was used as parameter for bioenergetic status. Intracapillary HbO2 saturation status reflects the oxygen supply conditions in tumors and was measured in vitro using a cryospectrophotometric method. The KHT, RIF-1, and MLS lines showed decreasing bioenergetic status, i.e., decreasing PCr and NTP beta resonances and an increasing Pi resonance, with increasing tumor volume, whereas the OWI line showed no changes in these resonances during tumor growth. The volume-dependence of the HbO2 saturation status differed similarly among the tumor lines; HbO2 saturation status decreased with increasing tumor volume for the KHT, RIF-1, and MLS lines and was independent of tumor volume for the OWI line. Moreover, linear correlations were found between bioenergetic status and HbO2 saturation status for individual tumors of the KHT, RIF-1, and MLS lines. These observations together indicated a direct relationship between 31P-NMR spectral parameters and tumor oxygen supply conditions. However, this relationship was not identical for the different tumor lines, suggesting that it was influenced by intrinsic properties of the tumor cells such as rate of respiration and ability to survive under hypoxia. Similarly, there was no correlation between bioenergetic status and fraction of radiobiologically hypoxic cells across the four tumor lines. This indicates that 31P-NMR spectroscopy data have to be supplemented with other data, e.g., rate of oxygen consumption, cell survival time under hypoxic stress, and/or fraction of metabolically active

  19. Characterizing sampling and quality screening biases in infrared and microwave limb sounding

    Science.gov (United States)

    Millán, Luis F.; Livesey, Nathaniel J.; Santee, Michelle L.; von Clarmann, Thomas

    2018-03-01

    This study investigates orbital sampling biases and evaluates the additional impact caused by data quality screening for the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) and the Aura Microwave Limb Sounder (MLS). MIPAS acts as a proxy for typical infrared limb emission sounders, while MLS acts as a proxy for microwave limb sounders. These biases were calculated for temperature and several trace gases by interpolating model fields to real sampling patterns and, additionally, screening those locations as directed by their corresponding quality criteria. Both instruments have dense uniform sampling patterns typical of limb emission sounders, producing almost identical sampling biases. However, there is a substantial difference between the number of locations discarded. MIPAS, as a mid-infrared instrument, is very sensitive to clouds, and measurements affected by them are thus rejected from the analysis. For example, in the tropics, the MIPAS yield is strongly affected by clouds, while MLS is mostly unaffected. The results show that upper-tropospheric sampling biases in zonally averaged data, for both instruments, can be up to 10 to 30 %, depending on the species, and up to 3 K for temperature. For MIPAS, the sampling reduction due to quality screening worsens the biases, leading to values as large as 30 to 100 % for the trace gases and expanding the 3 K bias region for temperature. This type of sampling bias is largely induced by the geophysical origins of the screening (e.g. clouds). Further, analysis of long-term time series reveals that these additional quality screening biases may affect the ability to accurately detect upper-tropospheric long-term changes using such data. In contrast, MLS data quality screening removes sufficiently few points that no additional bias is introduced, although its penetration is limited to the upper troposphere, while MIPAS may cover well into the mid-troposphere in cloud-free scenarios. We emphasize that the

  20. THE USE OF MOBILE LASER SCANNING DATA AND UNMANNED AERIAL VEHICLE IMAGES FOR 3D MODEL RECONSTRUCTION

    Directory of Open Access Journals (Sweden)

    L. Zhu

    2013-08-01

    Full Text Available The increasing availability in multiple data sources acquired by different sensor platforms has provided the great advantages for desired result achievement. This paper proposes the use of both mobile laser scanning (MLS data and Unmanned Aerial Vehicle (UAV images for 3D model reconstruction. Due to no available exterior orientation parameters for UAV images, the first task is to georeference these images to 3D points. In order to fast and accurate acquire 3D points which are also easy to be found the corresponding locations on UAV images, automated pole extraction from MLS was developed. After georeferencing UAV images, building roofs are acquired from those images and building walls are extracted from MLS data. The roofs and the walls are combined to achieve the complete building models.

  1. Geometric validation of a mobile laser scanning system for urban applications

    Science.gov (United States)

    Guan, Haiyan; Li, Jonathan; Yu, Yongtao; Liu, Yan

    2016-03-01

    Mobile laser scanning (MLS) technologies have been actively studied and implemented over the past decade, as their application fields are rapidly expanding and extending beyond conventional topographic mapping. Trimble's MX-8, as one of the MLS systems in the current market, generates rich survey-grade laser and image data for urban surveying. The objective of this study is to evaluate whether Trimble MX-8 MLS data satisfies the accuracy requirements of urban surveying. According to the formula of geo-referencing, accuracies of navigation solution and laser scanner determines the accuracy of the collected LiDAR point clouds. Two test sites were selected to test the performance of Trimble MX-8. Those extensive tests confirm that Trimble MX-8 offers a very promising tool to survey complex urban areas.

  2. Spectroscopic monitoring of NO traces in plants and human breath: applications and perspectives

    DEFF Research Database (Denmark)

    Cristescu, S M; Marchenko, D; Mandon, J

    2012-01-01

    monitoring of NO concentrations in exhaled breath, and from plants under pathogen attack. A simple hand-held breath sampling device that allows single breath collection at various exhalation flows (15, 50, 100 and 300mL/s, respectively) is developed for off-line measurements and validated in combination...... with the WMS-based sensor. Additionally, the capability of plants to remove environmental NO is presented....

  3. Interpretation of Aura satellite observations of CO and aerosol index related to the December 2006 Australia fires

    Science.gov (United States)

    Luo, M.; Boxe, C.; Jiang, J.; Nassar, R.; Livesey, N.

    2009-11-01

    Enhanced Carbon Monoxide (CO) in the upper troposphere (UT) is shown by collocated Tropospheric Emission Spectrometer (TES) and Microwave Limb Sounder (MLS) measurements near and down-wind from the known wildfire region of SE Australia from 12-19 December 2006. Enhanced UV aerosol index (AI) derived from Ozone Monitoring Instrument (OMI) measurements correlate with these high CO concentrations. HYSPLIT model back trajectories trace selected air parcels to the SE Australia fire region as their initial location, where TES observes enhanced CO in the upper and lower troposphere. Simultaneously, they show a lack of vertical advection along their tracks. TES retrieved CO vertical profiles in the higher and lower southern latitudes are examined together with the averaging kernels and show that TES CO retrievals are most sensitive at approximately 300-400 hPa. The enhanced CO observed by TES at the upper (215 hPa) and lower (681 hPa) troposphere are, therefore, influenced by mid-tropospheric CO. GEOS-Chem model simulations with an 8-day emission inventory, as the wildfire source over Australia, are sampled to the TES/MLS observation times and locations. These simulations only show CO enhancements in the lower troposphere near and down-wind from the wildfire region of SE Australia with drastic underestimates of UT CO. Although CloudSat along-track ice-water content curtains are examined to see whether possible vertical convection events can explain the high UT CO values, sparse observations of collocated Aura CO and CloudSat along-track ice-water content measurements for the single event precludes any conclusive correlation. Vertical convection that uplift fire-induced CO (i.e. most notably referred to as pyro-cumulonimbus, pyroCb) may provide an explanation for the incongruence between these simulations and the TES/MLS observations of enhanced CO in the UT. Future GEOS-Chem simulations are needed to validate this conjecture as the the PyroCb mechanism is currently not

  4. Abundance and distribution of Macrolide-Lincosamide-Streptogramin resistance genes in an anaerobic-aerobic system treating spiramycin production wastewater.

    Science.gov (United States)

    Liu, Miaomiao; Ding, Ran; Zhang, Yu; Gao, Yingxin; Tian, Zhe; Zhang, Tong; Yang, Min

    2014-10-15

    The behaviors of the Macrolide-Lincosamide-Streptogramin (MLS) resistance genes were investigated in an anaerobic-aerobic pilot-scale system treating spiramycin (SPM) production wastewater. After screening fifteen typical MLS resistance genes with different mechanisms using conventional PCR, eight detected genes were determined by quantitative PCR, together with three mobile elements. Aerobic sludge in the pilot system exhibited a total relative abundance of MLS resistance genes (per 16S rRNA gene) 2.5 logs higher than those in control samples collected from sewage and inosine wastewater treatment systems (P resistance genes. However, the total relative gene abundance in anaerobic sludge (4.3 × 10(-1)) was lower than that in aerobic sludge (3.7 × 10(0)) despite of the higher SPM level in anaerobic reactor, showing the advantage of anaerobic treatment in reducing the production of MLS resistance genes. The rRNA methylase genes (erm(B), erm(F), erm(X)) were the most abundant in the aerobic sludge (5.3 × 10(-1)-1.7 × 10(0)), followed by esterase gene ere(A) (1.3 × 10(-1)) and phosphorylase gene mph(B) (5.7 × 10(-2)). In anaerobic sludge, erm(B), erm(F), ere(A), and msr(D) were the major ones (1.2 × 10(-2)-3.2 × 10(-1)). These MLS resistance genes (except for msr(D)) were positively correlated with Class 1 integron (r(2) = 0.74-0.93, P < 0.05), implying the significance of horizontal transfer in their proliferation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Mobile phone technology identifies and recruits trained citizens to perform CPR on out-of-hospital cardiac arrest victims prior to ambulance arrival.

    Science.gov (United States)

    Ringh, Mattias; Fredman, David; Nordberg, Per; Stark, Tomas; Hollenberg, Jacob

    2011-12-01

    In a two-parted study, evaluate a new concept were mobile phone technology is used to dispatch lay responders to nearby out-of-hospital cardiac arrests (OHCAs). Mobile phone positioning systems (MPS) can geographically locate selected mobile phone users at any given moment. A mobile phone service using MPS was developed and named Mobile Life Saver (MLS). Simulation study: 25 volunteers named mobile responders (MRs) were connected to MLS. Ambulance time intervals from 22 consecutive OHCAs in 2005 were used as controls. The MRs randomly moved in Stockholm city centre and were dispatched to simulated OHCAs (identical to controls) if they were within a 350 m distance. Real life study: during 25 weeks 1271-1801 MRs trained in CPR were connected to MLS. MLS was activated at the dispatch centre in parallel with ambulance dispatch when an OHCA was suspected. The MRs were dispatched if they were within 500 m from the suspected OHCA. Simulation study: mean response time for the MRs compared to historical ambulance time intervals was reduced by 2 min 20s (44%), pMobile phone technology can be used to identify and recruit nearby CPR-trained citizens to OHCAs for bystander CPR prior to ambulance arrival. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Short-Term Outcome of Multiple Port Laparoscopic Splenectomy in 10 Dogs.

    Science.gov (United States)

    Shaver, Stephanie L; Mayhew, Philipp D; Steffey, Michele A; Hunt, Geraldine B; Mayhew, Kelli N; Culp, William T N

    2015-07-01

    To describe surgical techniques for multiple port laparoscopic splenectomy (MLS) in dogs and report short-term outcome. Retrospective case series. Dogs (n = 10) with naturally occurring splenic disease. Medical records (March 2012-March 2013) of dogs that had MLS were reviewed. Data retrieved included signalment, weight, clinical signs, physical examination findings, preoperative laboratory and ultrasonographic findings, port number, size, and location, patient positioning, additional procedures performed, surgical duration, histopathologic diagnosis, duration of hospitalization, and perioperative complications. Ten dogs (median weight, 28.7 kg; range, 20.2-46.0 kg) had MLS using a 3 or 4 port technique and a vessel-sealing device for tissue dissection along the splenic hilus. Dog positioning varied because of additional laparoscopic or laparoscopic-assisted procedures including adrenalectomy (n = 2), ovariectomy (1), gastropexy (1), and intestinal resection and anastomosis (1). Conversion to an open approach was necessary in 1 dog because of inadequate visibility caused by omental adhesions. One dog had hemorrhage from an omental vessel, but open conversion was not required. MLS was associated with little perioperative morbidity and few complications in this cohort of dogs and may be a reasonable option for surgical management of dogs requiring elective splenectomy. © Copyright 2014 by The American College of Veterinary Surgeons.

  7. The malate synthase of Paracoccidioides brasiliensis is a linked surface protein that behaves as an anchorless adhesin

    Directory of Open Access Journals (Sweden)

    Pereira Maristela

    2009-12-01

    Full Text Available Abstract Background The pathogenic fungus Paracoccidioides brasiliensis is the agent of paracoccidioidomycosis (PCM. This is a pulmonary mycosis acquired by inhalation of fungal airborne propagules that can disseminate to several organs and tissues leading to a severe form of the disease. Adhesion and invasion to host cells are essential steps involved in the internalization and dissemination of pathogens. Inside the host, P. brasiliensis may use the glyoxylate cycle for intracellular survival. Results Here, we provide evidence that the malate synthase of P. brasiliensis (PbMLS is located on the fungal cell surface, and is secreted. PbMLS was overexpressed in Escherichia coli, and polyclonal antibody was obtained against this protein. By using Confocal Laser Scanning Microscopy, PbMLS was detected in the cytoplasm and in the cell wall of the mother, but mainly of budding cells of the P. brasiliensis yeast phase. PbMLSr and its respective polyclonal antibody produced against this protein inhibited the interaction of P. brasiliensis with in vitro cultured epithelial cells A549. Conclusion These observations indicated that cell wall-associated PbMLS could be mediating the binding of fungal cells to the host, thus contributing to the adhesion of fungus to host tissues and to the dissemination of infection, behaving as an anchorless adhesin.

  8. Vertical and interhemispheric links in the stratosphere-mesosphere as revealed by the day-to-day variability of Aura-MLS temperature data

    Directory of Open Access Journals (Sweden)

    X. Xu

    2009-09-01

    Full Text Available The coupling processes in the middle atmosphere have been a subject of intense research activity because of their effects on atmospheric circulation, structure, variability, and the distribution of chemical constituents. In this study, the day-to-day variability of Aura-MLS (Microwave Limb Sounder temperature data are used to reveal the vertical and interhemispheric coupling processes in the stratosphere-mesosphere during four Northern Hemisphere winters (2004/2005–2007/2008. The UKMO (United Kingdom Meteorological Office assimilated data and mesospheric winds from MF (medium frequency radars are also applied to help highlight the coupling processes.

    In this study, a clear vertical link can be seen between the stratosphere and mesosphere during winter months. The coolings and reversals of northward meridional winds in the polar winter mesosphere are often observed in relation to warming events (Sudden Stratospheric Warming, SSW for short and the associated changes in zonal winds in the polar winter stratosphere. An upper-mesospheric cooling usually precedes the beginning of the warming in the stratosphere by 1–2 days.

    Inter-hemispheric coupling has been identified initially by a correlation analysis using the year-to-year monthly zonal mean temperature. Then the correlation analyses are performed based upon the daily zonal mean temperature. From the original time sequences, significant positive (negative correlations are generally found between zonal mean temperatures at the Antarctic summer mesopause and in the Arctic winter stratosphere (mesosphere during northern mid-winters, although these correlations are dominated by the low frequency variability (i.e. the seasonal trend. Using the short-term oscillations (less than 15 days, the statistical result, by looking for the largest magnitude of correlation within a range of time-lags (0 to 10 days; positive lags mean that the Antarctic summer mesopause is lagging, indicates

  9. Vertical and interhemispheric links in the stratosphere-mesosphere as revealed by the day-to-day variability of Aura-MLS temperature data

    Directory of Open Access Journals (Sweden)

    X. Xu

    2009-09-01

    Full Text Available The coupling processes in the middle atmosphere have been a subject of intense research activity because of their effects on atmospheric circulation, structure, variability, and the distribution of chemical constituents. In this study, the day-to-day variability of Aura-MLS (Microwave Limb Sounder temperature data are used to reveal the vertical and interhemispheric coupling processes in the stratosphere-mesosphere during four Northern Hemisphere winters (2004/2005–2007/2008. The UKMO (United Kingdom Meteorological Office assimilated data and mesospheric winds from MF (medium frequency radars are also applied to help highlight the coupling processes. In this study, a clear vertical link can be seen between the stratosphere and mesosphere during winter months. The coolings and reversals of northward meridional winds in the polar winter mesosphere are often observed in relation to warming events (Sudden Stratospheric Warming, SSW for short and the associated changes in zonal winds in the polar winter stratosphere. An upper-mesospheric cooling usually precedes the beginning of the warming in the stratosphere by 1–2 days. Inter-hemispheric coupling has been identified initially by a correlation analysis using the year-to-year monthly zonal mean temperature. Then the correlation analyses are performed based upon the daily zonal mean temperature. From the original time sequences, significant positive (negative correlations are generally found between zonal mean temperatures at the Antarctic summer mesopause and in the Arctic winter stratosphere (mesosphere during northern mid-winters, although these correlations are dominated by the low frequency variability (i.e. the seasonal trend. Using the short-term oscillations (less than 15 days, the statistical result, by looking for the largest magnitude of correlation within a range of time-lags (0 to 10 days; positive lags mean that the Antarctic summer mesopause is lagging, indicates that the temporal

  10. CO measurements from the ACE-FTS satellite instrument: data analysis and validation using ground-based, airborne and spaceborne observations

    Directory of Open Access Journals (Sweden)

    C. Clerbaux

    2008-05-01

    Full Text Available The Atmospheric Chemistry Experiment (ACE mission was launched in August 2003 to sound the atmosphere by solar occultation. Carbon monoxide (CO, a good tracer of pollution plumes and atmospheric dynamics, is one of the key species provided by the primary instrument, the ACE-Fourier Transform Spectrometer (ACE-FTS. This instrument performs measurements in both the CO 1-0 and 2-0 ro-vibrational bands, from which vertically resolved CO concentration profiles are retrieved, from the mid-troposphere to the thermosphere. This paper presents an updated description of the ACE-FTS version 2.2 CO data product, along with a comprehensive validation of these profiles using available observations (February 2004 to December 2006. We have compared the CO partial columns with ground-based measurements using Fourier transform infrared spectroscopy and millimeter wave radiometry, and the volume mixing ratio profiles with airborne (both high-altitude balloon flight and airplane observations. CO satellite observations provided by nadir-looking instruments (MOPITT and TES as well as limb-viewing remote sensors (MIPAS, SMR and MLS were also compared with the ACE-FTS CO products. We show that the ACE-FTS measurements provide CO profiles with small retrieval errors (better than 5% from the upper troposphere to 40 km, and better than 10% above. These observations agree well with the correlative measurements, considering the rather loose coincidence criteria in some cases. Based on the validation exercise we assess the following uncertainties to the ACE-FTS measurement data: better than 15% in the upper troposphere (8–12 km, than 30% in the lower stratosphere (12–30 km, and than 25% from 30 to 100 km.

  11. Latitudinal extent of the January 2005 solar proton event in the Northern Hemisphere from satellite observations of hydroxyl

    Directory of Open Access Journals (Sweden)

    P. T. Verronen

    2007-11-01

    Full Text Available We utilise hydroxyl observations from the MLS/Aura satellite instrument to study the latitudinal extent of particle forcing in the northern polar region during the January 2005 solar proton event. MLS is the first satellite instrument to observe HOx changes during such an event. We also predict the hydroxyl changes with respect to the magnetic latitude by the Sodankylä Ion and Neutral Chemistry model, estimating the variable magnetic cutoff energies for protons using a parameterisation based on magnetosphere modelling and the planetary magnetic index Kp. In the middle and lower mesosphere, HOx species are good indicators of the changes in the atmosphere during solar proton events, because they respond rapidly to both increases and decreases in proton forcing. Also, atmospheric transport has a negligible effect on HOx because of its short chemical lifetime. The observations indicate the boundary of the proton forcing and a transition region, from none to the "full" effect, which ranges from about 57 to 64 degrees of magnetic latitude. When saturating the rigidity cutoff Kp at 6 in the model, as suggested by earlier studies using observations of cosmic radio noise absorption, the equatorward boundary of the transition region is offset by ≈2 degrees polewards compared with the data, thus the latitudinal extent of the proton forcing in the atmosphere is underestimated. However, the model predictions are in reasonable agreement with the MLS measurements when the Kp index is allowed to vary within its nominal range, i.e., from 1 to 9 in the cutoff calculation.

  12. Solar cycle variations in mesospheric carbon monoxide

    Science.gov (United States)

    Lee, Jae N.; Wu, Dong L.; Ruzmaikin, Alexander; Fontenla, Juan

    2018-05-01

    As an extension of Lee et al. (2013), solar cycle variation of carbon monoxide (CO) is analyzed with MLS observation, which covers more than thirteen years (2004-2017) including maximum of solar cycle 24. Being produced primarily by the carbon dioxide (CO2) photolysis in the lower thermosphere, the variations of the mesospheric CO concentration are largely driven by the solar cycle modulated ultraviolet (UV) variation. This solar signal extends down to the lower altitudes by the dynamical descent in the winter polar vortex, showing a time lag that is consistent with the average descent velocity. To characterize a global distribution of the solar impact, MLS CO is correlated with the SORCE measured total solar irradiance (TSI) and UV. As high as 0.8 in most of the polar mesosphere, the linear correlation coefficients between CO and UV/TSI are more robust than those found in the previous work. The photochemical contribution explains most (68%) of the total variance of CO while the dynamical contribution accounts for 21% of the total variance at upper mesosphere. The photochemistry driven CO anomaly signal is extended in the tropics by vertical mixing. The solar cycle signal in CO is further examined with the Whole Atmosphere Community Climate Model (WACCM) 3.5 simulation by implementing two different modeled Spectral Solar Irradiances (SSIs): SRPM 2012 and NRLSSI. The model simulations underestimate the mean CO amount and solar cycle variations of CO, by a factor of 3, compared to those obtained from MLS observation. Different inputs of the solar spectrum have small impacts on CO variation.

  13. Time-intensity curve in the abdominal aorta on dynamic contrast-enhanced MRI with high temporal and spatial resolution. Gd-EOB-DTPA versus Gd-DTPA in vivo

    International Nuclear Information System (INIS)

    Fujinaga, Yasunari; Tsukahara, Yoshinori; Sugiyama, Yukiko; Kadoya, Masumi; Ueda, Hitoshi; Kitou, Yoshihiro

    2013-01-01

    The purpose of this study was to evaluate the difference in the time-intensity curves (TICs) of the abdominal aorta on dynamic contrast-enhanced MRI (DCE-MRI) between gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA) and gadolinium ethoxybenzydiethylenetriamine pentaacetic acid (Gd-EOB-DTPA). Ten healthy volunteers underwent DCE-MRI three times with the following protocol: group A, Gd-DTPA at an injection rate of 3 ml/s; group B, Gd-EOB-DTPA, 3 ml/s; group C, Gd-EOB-DTPA, 1.5 ml/s. Signal intensities (SIs) of the abdominal aorta were measured, and the contrast enhancement ratio (CER) was calculated. Time-to-CER curves were compared among the three groups. The differences in maximum CER (CER max ) and time-to-peak of CER were analyzed. The time-to-CER curve showed a double peak pattern in group A and single-peak pattern in groups B and C. The mean time between the first and the second peak was 6.2 s. The mean CER max of each group was 4.50, 4.52 and 4.27, respectively. In group A, B and C, the mean time-to-peak was 14.6, 10.6 and 12.6 s, respectively. There was a significant difference between group A and B (P<0.01). To set up the optimal protocol for abdominal DCE-MRI, it should be noted that TIC in the Gd-DTPA and Gd-EOB-DTPA group showed different patterns, and a slower injection rate showed a less abrupt SI change in the Gd-EOB-DTPA group than in the Gd-DTPA group. (author)

  14. Brain activation to negative stimuli mediates a relationship between adolescent marijuana use and later emotional functioning

    OpenAIRE

    Heitzeg, Mary M.; Cope, Lora M.; Martz, Meghan E.; Hardee, Jillian E.; Zucker, Robert A.

    2015-01-01

    This work investigated the impact of heavy marijuana use during adolescence on emotional functioning, as well as the brain functional mediators of this effect. Participants (n = 40) were recruited from the Michigan Longitudinal Study (MLS). Data on marijuana use were collected prospectively beginning in childhood as part of the MLS. Participants were classified as heavy marijuana users (n = 20) or controls with minimal marijuana use. Two facets of emotional functioning—negative emotionality a...

  15. Multi-Level Secure Local Area Network

    OpenAIRE

    Naval Postgraduate School (U.S.); Center for Information Systems Studies Security and Research (CISR)

    2011-01-01

    Multi-Level Secure Local Area Network is a cost effective, multi-level, easy to use office environment leveraging existing high assurance technology. The Department of Defense and U.S. Government have an identified need to securely share information classified at differing security levels. Because there exist no commercial solutions to this problem, NPS is developing a MLS LAN. The MLS LAN extends high assurance capabilities of an evaluated multi-level secure system to commercial personal com...

  16. A simple bedside test to assess the swallowing dysfunction in Parkinson′s disease

    Directory of Open Access Journals (Sweden)

    S Vinoth Kanna

    2014-01-01

    Full Text Available Background: Swallowing changes are common in Parkinson′s disease (PD. Early identification is essential to avoid complications of aspiration. Objectives: To evaluate the swallowing ability of the PD patients and to correlate it with the indicators of disease progression. Materials and Methods: A total of 100 PD patients (70 males and 30 females aged between 50 years and 70 years with varying stage, duration, and severity were enrolled in a cross-sectional study carried out between January and May 2012. A simple bedside water swallowing test was performed using standard 150 ml of water. Swallowing process was assessed under three categories-swallowing speeds (ml/s, swallowing volume (ml/swallow and swallowing duration (s/swallow. Equal number of age and sex matched controls were also evaluated. Results: All of them completed the task of swallowing. A mean swallowing speed (27.48 ml/s, swallowing volume (28.5 ml/s, and swallowing duration (1.05 s/swallow was established by the control group. The PD patients showed decreased swallowing speed (7.15 ml/s in males and 6.61 ml/s in females, decreased swallowing volume (14.59 ml/swallow and 14 ml/swallow in females, and increased swallowing duration (2.37 s/swallow and 2.42 s/swallow which are statistically significant. There was a significant positive correlation between the severity, duration, and staging of the disease with the swallowing performance and a poor correlation between the subjective reports of dysphagia and the objective performance on water swallow test. Conclusion: The water swallowing test is a simple bedside test to identify the swallowing changes early in PD. It is recommended to do the test in all PD Patients to detect dysphagia early and to intervene appropriately.

  17. A parametric transfer function methodology for analyzing reactive transport in nonuniform flow.

    Science.gov (United States)

    Luo, Jian; Cirpka, Olaf A; Fienen, Michael N; Wu, Wei-min; Mehlhorn, Tonia L; Carley, Jack; Jardine, Philip M; Criddle, Craig S; Kitanidis, Peter K

    2006-02-01

    We analyze reactive transport during in-situ bioremediation in a nonuniform flow field, involving multiple extraction and injection wells, by the method of transfer functions. Gamma distributions are used as parametric models of the transfer functions. Apparent parameters of classical transport models may be estimated from those of the gamma distributions by matching temporal moments. We demonstrate the method by application to measured data taken at a field experiment on bioremediation conducted in a multiple-well system in Oak Ridge, TN. Breakthrough curves (BTCs) of a conservative tracer (bromide) and a reactive compound (ethanol) are measured at multi-level sampling (MLS) wells and in extraction wells. The BTCs of both compounds are jointly analyzed to estimate the first-order degradation rate of ethanol. To quantify the tracer loss, we compare the approaches of using a scaling factor and a first-order decay term. Results show that by including a scaling factor both gamma distributions and inverse-Gaussian distributions (transfer functions according to the advection-dispersion equation) are suitable to approximate the transfer functions and estimate the reactive rate coefficients for both MLS and extraction wells. However, using a first-order decay term for tracer loss fails to describe the BTCs at the extraction well, which is affected by the nonuniform distribution of travel paths.

  18. Electrical characterization of InAs/InP self-assembled quantum dots with InGaAs strain-relief layers

    International Nuclear Information System (INIS)

    Kim, J. S.; Kim, E. K.; Hwang, H.; Park, K.; Yoon, E.; Park, I. W.; Park, Y. J.

    2004-01-01

    We have investigated the energy levels of InAs quantum dots (QDs) embedded in various barrier layers such as InP, InGaAs and GaAs by using deep level transient spectroscopy (DLTS) measurement. The apparent activation energy of 0.56 eV below the conduction band edge of barrier layers in the InAs/InP QD system was higher than 0.32 eV in the InAs/In 0.53 Ga 0.47 As QD system or 0.29 eV in the InAs/GaAs/In 0.53 Ga 0.47 As QD system, which was inserted in 10 mono-layers (MLs) GaAs between InAs QDs and the InGaAs barrier. The capture barrier heights of InAs QDs in the InAs/InP system was measured at more than about 0.18 eV, showing the existence of strain between QDs and barrier layers. The InAs/GaAs(10 MLs)/InGaAs system also showed about 0.12 eV capture barrier, but the InAs/InGaAs system has a very small barrier. This result might originate from the strain-relief effect due to InGaAs layers.

  19. Growth and magnetic study of sputtered Fe/Al multilayers

    International Nuclear Information System (INIS)

    Cherif, S.M.; Bouziane, K.; Roussigne, Y.; Al-Busaidy, M.

    2007-01-01

    Brillouin light scattering (BLS) and vibrating sample magnetometry (VSM) were used to study the effect of interfacial intermixing and microstructure on the magnetic properties of DC magnetron sputtered Fe/Al multilayers (MLs) on Si(1 0 0) substrate. Three samples with nominal composition [Al (4 nm)/Fe (3.7 nm)] x18 and deposited under different negative DC bias voltages (V b = -50, -200 and -400 V) have been investigated. The X-ray diffraction results indicate that the FeAl MLs have a poor crystallinity with no evidence of the absence of B2 phase. The grazing X-ray reflectivity results suggest that the interfacial roughness and intermixing were gradually reduced from 0.7 to 0.5 nm (±0.05 nm) by increasing V b from -50 to -400 V. The magnetization measurements demonstrate the presence of in-plane uniaxial anisotropy and magnetically dead interfacial layers. The BLS results reveal spin-wave surface modes whose frequencies also depend on the applied V b . The same trend upon V b was observed for the perpendicular and in-plane anisotropies

  20. Growth and magnetic study of sputtered Fe/Al multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Cherif, S.M. [LPMTM (CNRS-UPR 9001), Universite Paris 13, 99 Av. J.B. Clement, 93430 Villetaneuse (France); Bouziane, K. [LPMTM (CNRS-UPR 9001), Universite Paris 13, 99 Av. J.B. Clement, 93430 Villetaneuse (France) and Department of Physics, College of Science, Sultan Qaboos University, P.O. Box 36, Al-Khodh 123 (Oman)]. E-mail: bouzi@squ.edu.om; Roussigne, Y. [LPMTM (CNRS-UPR 9001), Universite Paris 13, 99 Av. J.B. Clement, 93430 Villetaneuse (France); Al-Busaidy, M. [Department of Physics, College of Science, Sultan Qaboos University, P.O. Box 36, Al-Khodh 123 (Oman)

    2007-03-15

    Brillouin light scattering (BLS) and vibrating sample magnetometry (VSM) were used to study the effect of interfacial intermixing and microstructure on the magnetic properties of DC magnetron sputtered Fe/Al multilayers (MLs) on Si(1 0 0) substrate. Three samples with nominal composition [Al (4 nm)/Fe (3.7 nm)]{sub x18} and deposited under different negative DC bias voltages (V {sub b} = -50, -200 and -400 V) have been investigated. The X-ray diffraction results indicate that the FeAl MLs have a poor crystallinity with no evidence of the absence of B2 phase. The grazing X-ray reflectivity results suggest that the interfacial roughness and intermixing were gradually reduced from 0.7 to 0.5 nm ({+-}0.05 nm) by increasing V {sub b} from -50 to -400 V. The magnetization measurements demonstrate the presence of in-plane uniaxial anisotropy and magnetically dead interfacial layers. The BLS results reveal spin-wave surface modes whose frequencies also depend on the applied V{sub b}. The same trend upon V {sub b} was observed for the perpendicular and in-plane anisotropies.

  1. Automatic Extraction of Road Markings from Mobile Laser Scanning Data

    Science.gov (United States)

    Ma, H.; Pei, Z.; Wei, Z.; Zhong, R.

    2017-09-01

    Road markings as critical feature in high-defination maps, which are Advanced Driver Assistance System (ADAS) and self-driving technology required, have important functions in providing guidance and information to moving cars. Mobile laser scanning (MLS) system is an effective way to obtain the 3D information of the road surface, including road markings, at highway speeds and at less than traditional survey costs. This paper presents a novel method to automatically extract road markings from MLS point clouds. Ground points are first filtered from raw input point clouds using neighborhood elevation consistency method. The basic assumption of the method is that the road surface is smooth. Points with small elevation-difference between neighborhood are considered to be ground points. Then ground points are partitioned into a set of profiles according to trajectory data. The intensity histogram of points in each profile is generated to find intensity jumps in certain threshold which inversely to laser distance. The separated points are used as seed points to region grow based on intensity so as to obtain road mark of integrity. We use the point cloud template-matching method to refine the road marking candidates via removing the noise clusters with low correlation coefficient. During experiment with a MLS point set of about 2 kilometres in a city center, our method provides a promising solution to the road markings extraction from MLS data.

  2. The ultrastructure of bone and its relevance to mechanical properties

    Science.gov (United States)

    Schwarcz, Henry P.; Abueidda, Diab; Jasiuk, Iwona

    2017-09-01

    Bone is a biologically generated composite material comprised of two major structural components: crystals of apatite and collagen fibrils. Computational analysis of the mechanical properties of bone must make assumptions about the geometric and topological relationships between these components. Recent transmission electron microscope (TEM) studies of samples of bone prepared using ion milling methods have revealed important previously unrecognized features in the ultrastructure of bone. These studies show that most of the mineral in bone lies outside the fibrils and is organized into elongated plates 5 nanometers (nm) thick, 80 nm wide and hundreds of nm long. These so-called mineral lamellae (MLs) are mosaics of single 5 nm-thick, 20 - 50 nm wide crystals bonded at their edges. MLs occur either stacked around the 50 nm-diameter collagen fibrils, or in parallel stacks of 5 or more MLs situated between fibrils. About 20% of mineral is in gap zones within the fibrils. MLs are apparently glued together into mechanically coherent stacks which break across the stack rather than delaminating. ML stacks should behave as cohesive units during bone deformation. Finite element computations of mechanical properties of bone show that the model including such features generates greater stiffness and strength than are obtained using conventional models in which most of the mineral, in the form of isolated crystals, is situated inside collagen fibrils.

  3. Millimeter radiometer system technology

    Science.gov (United States)

    Wilson, W. J.; Swanson, P. N.

    1989-07-01

    JPL has had a large amount of experience with spaceborne microwave/millimeter wave radiometers for remote sensing. All of the instruments use filled aperture antenna systems from 5 cm diameter for the microwave Sounder Units (MSU), 16 m for the microwave limb sounder (MLS) to 20 m for the large deployable reflector (LDR). The advantages of filled aperture antenna systems are presented. The requirements of the 10 m Geoplat antenna system, 10 m multified antenna, and the MLS are briefly discussed.

  4. DIGITAL TERRAIN MODELS FROM MOBILE LASER SCANNING DATA IN MORAVIAN KARST

    Directory of Open Access Journals (Sweden)

    N. Tyagur

    2016-06-01

    Full Text Available During the last ten years, mobile laser scanning (MLS systems have become a very popular and efficient technology for capturing reality in 3D. A 3D laser scanner mounted on the top of a moving vehicle (e.g. car allows the high precision capturing of the environment in a fast way. Mostly this technology is used in cities for capturing roads and buildings facades to create 3D city models. In our work, we used an MLS system in Moravian Karst, which is a protected nature reserve in the Eastern Part of the Czech Republic, with a steep rocky terrain covered by forests. For the 3D data collection, the Riegl VMX 450, mounted on a car, was used with integrated IMU/GNSS equipment, which provides low noise, rich and very dense 3D point clouds. The aim of this work is to create a digital terrain model (DTM from several MLS data sets acquired in the neighbourhood of a road. The total length of two covered areas is 3.9 and 6.1 km respectively, with an average width of 100 m. For the DTM generation, a fully automatic, robust, hierarchic approach was applied. The derivation of the DTM is based on combinations of hierarchical interpolation and robust filtering for different resolution levels. For the generation of the final DTMs, different interpolation algorithms are applied to the classified terrain points. The used parameters were determined by explorative analysis. All MLS data sets were processed with one parameter set. As a result, a high precise DTM was derived with high spatial resolution of 0.25 x 0.25 m. The quality of the DTMs was checked by geodetic measurements and visual comparison with raw point clouds. The high quality of the derived DTM can be used for analysing terrain changes and morphological structures. Finally, the derived DTM was compared with the DTM of the Czech Republic (DMR 4G with a resolution of 5 x 5 m, which was created from airborne laser scanning data. The vertical accuracy of the derived DTMs is around 0.10 m.

  5. Human exposure to lead, cadmium and mercury through fish and seafood product consumption in Italy: a pilot evaluation.

    Science.gov (United States)

    Pastorelli, A A; Baldini, M; Stacchini, P; Baldini, G; Morelli, S; Sagratella, E; Zaza, S; Ciardullo, S

    2012-01-01

    The presence of selected toxic heavy metals, such as cadmium (Cd), lead (Pb) and mercury (Hg), was investigated in fish and seafood products, namely, blue mussel, carpet shell clam, European squid, veined squid, deep-water rose shrimp, red mullet, European seabass, gilthead seabream, Atlantic cod, European hake, Atlantic bluefin tuna and swordfish so as to assess their human exposure through diet. Metals were detected by quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS) and hydride generation atomic absorption spectrometry (Hg-AAS). Measurements of Cd, Pb and Hg were performed by means of analytical methods validated in compliance with UNI CEI EN ISO/IEC 17025 [2005. General requirements for the competence of testing and calibration laboratories. Milano (Italy): UNI Ente Nazionale Italiano di Unificazione]. The exposure assessment was undertaken matching the levels of Cd, Pb and total Hg with consumption data related to fish and seafood products selected for this purpose. In order to establish human health implications, the estimated weekly intakes (EWIs) for Cd, Pb and Hg were compared with the standard tolerable weekly intakes (TWI) for Cd and provisional tolerable weekly intakes (PTWIs) for Pb and Hg stipulated by the European Food Safety Authority (EFSA) and the Food and Agriculture Organization/World Health Organization (FAO/WHO) Joint Expert Committee on Food Additives (JECFA). The found metal concentrations were largely below the maximum levels (MLs) established at the European Union level with the exception of Cd. This metal exceeded the MLs in squid, red mullet, European hake and Atlantic cod. Squid and blue mussel showed the highest Pb concentrations which accounted for 60% and 10% of the MLs, respectively. Highest Hg levels were found in predatory fish. The concentrations of Hg in swordfish, Atlantic bluefin tuna and red mullet accounted for 50%, 30% and 30% of the MLs, respectively. The EWIs for Cd, Pb and Hg related to the consumption

  6. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children

    Directory of Open Access Journals (Sweden)

    Janson C

    2006-04-01

    Full Text Available Abstract Background Exhaled nitric oxide (NO measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO was compared with a standard stationary chemiluminescence unit (NIOX. Methods A total of 71 subjects (6–60 years; 36 males, both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots, measurement feasibility (success rate with 6 attempts and repeatability (intrasubject SD. Results Success rate was high (≥ 84% in both devices for both adults and children. The subjects represented a FENO range of 8–147 parts per billion (ppb. When comparing the mean of three measurements (n = 61, the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. Conclusion The hand-held device (NIOX MINO and the stationary system (NIOX are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO is used. The hand-held device shows good repeatability, and it

  7. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children.

    Science.gov (United States)

    Alving, K; Janson, C; Nordvall, L

    2006-04-20

    Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). A total of 71 subjects (6-60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). Success rate was high (> or = 84%) in both devices for both adults and children. The subjects represented a FENO range of 8-147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children

  8. Submillimeter-wave measurements of the pressure broadening of BrO

    International Nuclear Information System (INIS)

    Yamada, M.M.; Kobayashi, M.; Habara, H.; Amano, T.; Drouin, B.J.

    2003-01-01

    The N 2 and O 2 pressure broadening coefficients of the J=23.5 ↔ 22.5 and J=25.5 ↔ 24.5 rotational transitions in the ground vibronic state X 2 Π 3/2 of 81 BrO at 624.768 and 650.178 GHz have been independently measured at Ibaraki University and Jet Propulsion Laboratory. These lines are expected to be monitored by the superconducting submillimeter-wave limb emission sounder in the Japanese Experiment Module on the International Space Station (JEM/SMILES) as well as the earth observing system microwave limb sounder (EOS-MLS). This work provides temperature-dependent pressure broadening parameters of BrO needed by the space station and satellite based observations. The BrO pressure broadening coefficients and their 1σ uncertainties are: γ 0 (N 2 )=3.24±0.05 MHz/Torr and γ 0 (O 2 )=2.33±0.06 MHz/Torr for the 624.768 GHz transition at room temperature (296 K). For the 650.178 GHz line, the results are: γ 0 (N 2 )=3.20±0.07 MHz/Torr and γ 0 (O 2 )=2.41±0.06 MHz/Torr. The temperature dependence exponents and their 1σ error are determined to be: n(N 2 )=-0.76±0.05 and n(O 2 )=-0.93±0.07 for the 624.768 GHz transition, and n(N 2 )=-0.84±0.07 and n(O 2 )=-0.70±0.07 for the 650.178 GHz transition

  9. BENCHMARKING MOBILE LASER SCANNING SYSTEMS USING A PERMANENT TEST FIELD

    Directory of Open Access Journals (Sweden)

    H. Kaartinen

    2012-07-01

    Full Text Available The objective of the study was to benchmark the geometric accuracy of mobile laser scanning (MLS systems using a permanent test field under good coverage of GNSS. Mobile laser scanning, also called mobile terrestrial laser scanning, is currently a rapidly developing area in laser scanning where laser scanners, GNSS and IMU are mounted onboard a moving vehicle. MLS can be considered to fill the gap between airborne and terrestrial laser scanning. Data provided by MLS systems can be characterized with the following technical parameters: a point density in the range of 100-1000 points per m2 at 10 m distance, b distance measurement accuracy of 2-5 cm, and c operational scanning range from 1 to 100 m. Several commercial, including e.g. Riegl, Optech and others, and some research mobile laser scanning systems surveyed the test field using predefined driving speed and directions. The acquired georeferenced point clouds were delivered for analyzing. The geometric accuracy of the point clouds was determined using the reference targets that could be identified and measured from the point cloud. Results show that in good GNSS conditions most systems can reach an accuracy of 2 cm both in plane and elevation. The accuracy of a low cost system, the price of which is less than tenth of the other systems, seems to be within a few centimetres at least in ground elevation determination. Inaccuracies in the relative orientation of the instruments lead to systematic errors and when several scanners are used, in multiple reproductions of the objects. Mobile laser scanning systems can collect high density point cloud data with high accuracy. A permanent test field suits well for verifying and comparing the performance of different mobile laser scanning systems. The accuracy of the relative orientation between the mapping instruments needs more attention. For example, if the object is seen double in the point cloud due to imperfect boresight calibration between two

  10. MULTI-LEVEL SAMPLING APPROACH FOR CONTINOUS LOSS DETECTION USING ITERATIVE WINDOW AND STATISTICAL MODEL

    OpenAIRE

    Mohd Fo'ad Rohani; Mohd Aizaini Maarof; Ali Selamat; Houssain Kettani

    2010-01-01

    This paper proposes a Multi-Level Sampling (MLS) approach for continuous Loss of Self-Similarity (LoSS) detection using iterative window. The method defines LoSS based on Second Order Self-Similarity (SOSS) statistical model. The Optimization Method (OM) is used to estimate self-similarity parameter since it is fast and more accurate in comparison with other estimation methods known in the literature. Probability of LoSS detection is introduced to measure continuous LoSS detection performance...

  11. Parametric and quantitative analysis of MR renographic curves for assessing the functional behaviour of the kidney

    Energy Technology Data Exchange (ETDEWEB)

    Michoux, N.; Montet, X.; Pechere, A.; Ivancevic, M.K.; Martin, P.-Y.; Keller, A.; Didier, D.; Terrier, F.; Vallee, J.-P

    2005-04-01

    The aim of this study was to refine the description of the renal function based on MR images and through transit-time curve analysis on a normal population and on a population with renal failure, using the quantitative model of the up-slope. Thirty patients referred for a kidney MR exam were divided in a first population with well-functioning kidneys and in a second population with renal failure from ischaemic kidney disease. The perfusion sequence consisted of an intravenous injection of Gd-DTPA and of a fast GRE sequence T1-TFE with 90 deg. magnetisation preparation (Intera 1.5 T MR System, Philips Medical System). To convert the signal intensity into 1/T1, which is proportional to the contrast media concentration, a flow-corrected calibration procedure was used. Following segmentation of regions of interest in the cortex and medulla of the kidney and in the abdominal aorta, outflow curves were obtained and filtered to remove the high frequency fluctuations. The model of the up-slope method was then applied. Significant reduction of the cortical perfusion (Q{sub c}=0.057{+-}0.030 ml/(s 100 g) to Q{sub c}=0.030{+-}0.017 ml/(s 100 g), P<0.013), of the medullary perfusion (Q{sub m}=0.023{+-}0.018 ml/(s 100 g) to Q{sub m}=0.011{+-}0.006 ml/(s 100 g), P<0.046) and of the accumulation of contrast media in the medulla (Q{sub a}=0.005{+-}0.003 ml/(s 100 g) to Q{sub a}=0.0009{+-}0.0008 ml/(s 100 g), P<0.001) were found in presence of renal failure. High correlations were found between the creatinine level and the accumulation Q{sub a} in the medulla (r{sup 2}=0.72, P<0.05), and between the perfusion ratio Q{sub c}/Q{sub m} and the accumulation Q{sub a} in the medulla (r{sup 2}=0.81, P<0.05). No significant difference was found in times to peak between both populations despite a trend showing T{sub a} the time to the end of the increasing contrast accumulation period in the medulla, arriving later for renal failure. Advances in MR signal calibration with the building of

  12. AUTOMATIC EXTRACTION OF ROAD MARKINGS FROM MOBILE LASER SCANNING DATA

    Directory of Open Access Journals (Sweden)

    H. Ma

    2017-09-01

    Full Text Available Road markings as critical feature in high-defination maps, which are Advanced Driver Assistance System (ADAS and self-driving technology required, have important functions in providing guidance and information to moving cars. Mobile laser scanning (MLS system is an effective way to obtain the 3D information of the road surface, including road markings, at highway speeds and at less than traditional survey costs. This paper presents a novel method to automatically extract road markings from MLS point clouds. Ground points are first filtered from raw input point clouds using neighborhood elevation consistency method. The basic assumption of the method is that the road surface is smooth. Points with small elevation-difference between neighborhood are considered to be ground points. Then ground points are partitioned into a set of profiles according to trajectory data. The intensity histogram of points in each profile is generated to find intensity jumps in certain threshold which inversely to laser distance. The separated points are used as seed points to region grow based on intensity so as to obtain road mark of integrity. We use the point cloud template-matching method to refine the road marking candidates via removing the noise clusters with low correlation coefficient. During experiment with a MLS point set of about 2 kilometres in a city center, our method provides a promising solution to the road markings extraction from MLS data.

  13. Dorsal onlay lingual mucosal graft urethroplasty for urethral strictures in women.

    Science.gov (United States)

    Sharma, Girish K; Pandey, Ashwani; Bansal, Harbans; Swain, Sameer; Das, Suren K; Trivedi, Sameer; Dwivedi, Udai S; Singh, Pratap B

    2010-05-01

    To describe the technique and results of dorsal onlay lingual mucosal graft (LMG) urethroplasty for the definitive management of urethral strictures in women. In all, 15 women (mean age 42 years) with a history suggestive of urethral stricture who had undergone multiple urethral dilatations and/or urethrotomy were selected for dorsal onlay LMG urethroplasty after thorough evaluation, from October 2006 to March 2008. After a suprameatal inverted-U incision, the dorsal aspect of the urethra was dissected and urethrotomy was done at the 12 o'clock position across the strictured segment. Tailored LMG harvested from the ventrolateral aspect of the tongue was then sutured to the urethrotomy wound over an 18 F silicone catheter. The preoperative mean maximum urinary flow rate of 7.2 mL/s increased to 29.87 mL/s, 26.95 mL/s and 26.86 mL/s with a 'normal' flow rate curve at 3, 6 and 12 months follow-up, respectively. One patient at the 3-month follow-up had submeatal stenosis and required urethral dilatation thrice at monthly intervals. At the 1-year follow-up, none of the present patients had any neurosensory complications, urinary incontinence, or long-term functional/aesthetic complication at the donor site. LMG urethroplasty using the dorsal onlay technique should be offered for correction of persistent female urethral stricture as it provides a simple, safe and effective approach with durable results.

  14. Urine flow acceleration is superior to Qmax in diagnosing BOO in patients with BPH.

    Science.gov (United States)

    Wen, Jian-guo; Cui, Lin-gang; Li, Yi-dong; Shang, Xiao-ping; Zhu, Wen; Zhang, Rui-li; Meng, Qing-jun; Zhang, Sheng-jun

    2013-08-01

    We performed a retrospective, case-control study to evaluate whether the urine flow acceleration (UFA, mL/s(2)) is superior to maximum uroflow (Qmax, mL/s) in diagnosing bladder outlet obstruction (BOO) in patients with benign prostatic hyperplasia (BPH). In this study, a total of 50 men with BPH (age: 58±12.5 years) and 50 controls (age: 59±13.0 years) were included. A pressure-flow study was used to determine the presence of BOO according to the recommendations of Incontinence Control Society (ICS). The results showed that the UFA and Qmax in BPH group were much lower than those in the control group [(2.05±0.85) vs. (4.60±1.25) mL/s(2) and (8.50±1.05) vs. (13.00±3.35) mL/s] (PBOO were 88%, 75% vs. 81%, 63%. UFA vs. Omax, when compared with the results of P-Q chart (the kappa values in corresponding analysis), was 0.55 vs. 0.35. The prostate volume, post void residual and detrusor pressure at Qmax between the two groups were 28.6±9.8 vs. 24.2±7.6 mL, 60.4±1.4 vs. 21.3±2.5 mL and 56.6±8.3 vs. 21.7±6.1 cmH2O, respectively (PBOO in patients with BPH.

  15. Automatic Generation of Indoor Navigable Space Using a Point Cloud and its Scanner Trajectory

    Science.gov (United States)

    Staats, B. R.; Diakité, A. A.; Voûte, R. L.; Zlatanova, S.

    2017-09-01

    Automatic generation of indoor navigable models is mostly based on 2D floor plans. However, in many cases the floor plans are out of date. Buildings are not always built according to their blue prints, interiors might change after a few years because of modified walls and doors, and furniture may be repositioned to the user's preferences. Therefore, new approaches for the quick recording of indoor environments should be investigated. This paper concentrates on laser scanning with a Mobile Laser Scanner (MLS) device. The MLS device stores a point cloud and its trajectory. If the MLS device is operated by a human, the trajectory contains information which can be used to distinguish different surfaces. In this paper a method is presented for the identification of walkable surfaces based on the analysis of the point cloud and the trajectory of the MLS scanner. This method consists of several steps. First, the point cloud is voxelized. Second, the trajectory is analysing and projecting to acquire seed voxels. Third, these seed voxels are generated into floor regions by the use of a region growing process. By identifying dynamic objects, doors and furniture, these floor regions can be modified so that each region represents a specific navigable space inside a building as a free navigable voxel space. By combining the point cloud and its corresponding trajectory, the walkable space can be identified for any type of building even if the interior is scanned during business hours.

  16. Five Blind Men and an Elephant: Comparing Aura Ozone Datasets and Sonde with Model Simulations

    Science.gov (United States)

    Tang, Q.; Prather, M. J.

    2011-12-01

    The four Earth Observing System (EOS) Aura satellite ozone measurements (HIRDLS, MLS, OMI, and TES) as well as the coincident WOUDC sonde are the five ``blind men'' touching the ``elephant'' (ozone). They all measure ozone (O3) in the upper troposphere and lower stratosphere (UT/LS) region, providing the great opportunity to study how the tropospheric ozone is influenced by the stratospheric source, an important tropospheric ozone budget term with large uncertainties and discrepancies across different models and methods. Based upon the 2-D autocorrelation for the tropospheric column ozone anomalies of the OMI swaths, we show that the stratosphere-troposphere exchange (STE) processes occur on the scale of a few hundred kilometers. Applying the high resolution (1o±1o±40-layer±0.5 hr) atmospheric chemistry transport model (CTM) as a transfer standard, we compare the noncoincident Aura level 2 swath datasets with the exact matching simulations of each measurement to investigate the consistency of different instruments as well as evaluate the accuracy of modeled ozone. Different signs of the CTM biases against HIRDLS, MLS, and TES are found from tropics to northern hemisphere (NH) mid-latitudes in July 2005 at 215 hPa and over tropics at 147 hPa for July 2005 and January 2006, suggesting inconsistency across these Aura datasets. On the other hand, the CTM has great positive biases against satellite observations in the lower stratosphere of winter time southern hemisphere (SH) mid-latitudes, which is probably attributed to the problems in the stratospheric circulation of the driving met-fields. The model's ability of reproducing STE-related processes, such as tropospheric folds (TFs), is confirmed by the comparisons with WOUDC sonde. We found eight cases in year 2005 with all the four Aura measurements available and folding structures in the coincident sonde profile. The case studies indicate that all the four Aura instruments demonstrate some skills in catching the

  17. Randomized, double-blind, placebo-controlled trial of saw palmetto in men with lower urinary tract symptoms.

    Science.gov (United States)

    Gerber, G S; Kuznetsov, D; Johnson, B C; Burstein, J D

    2001-12-01

    To assess the effects of saw palmetto on urinary symptoms, sexual function, and urinary flow rate in men with lower urinary tract symptoms using a double-blind, randomized, placebo-controlled trial. The eligible patients were 45 years of age or older and had an International Prostate Symptom Score of 8 or greater. After a 1-month placebo run-in period, 85 men were randomized to receive saw palmetto or placebo for 6 months. Patients were evaluated using the International Prostate Symptom Score, a sexual function questionnaire, and by measurement of the urinary flow rate. The mean symptom score decreased from 16.7 to 12.3 in the saw palmetto group compared with 15.8 to 13.6 in the placebo group (P = 0.038). The quality-of-life score improved to a greater degree in the saw palmetto group, but this difference was not statistically significant. No change occurred in the sexual function questionnaire results in either group. The peak flow rate increased by 1.0 mL/s and 1.4 mL/s in the saw palmetto and placebo groups, respectively (P = 0.73). Saw palmetto led to a statistically significant improvement in urinary symptoms in men with lower urinary tract symptoms compared with placebo. Saw palmetto had no measurable effect on the urinary flow rates. The mechanism by which saw palmetto improves urinary symptoms remains unknown.

  18. Mobile Laser Scanning along Dieppe coastal cliffs: reliability of the acquired point clouds applied to rockfall assessments

    Science.gov (United States)

    Michoud, Clément; Carrea, Dario; Augereau, Emmanuel; Cancouët, Romain; Costa, Stéphane; Davidson, Robert; Delacourt, Chirstophe; Derron, Marc-Henri; Jaboyedoff, Michel; Letortu, Pauline; Maquaire, Olivier

    2013-04-01

    Dieppe coastal cliffs, in Normandy, France, are mainly formed by sub-horizontal deposits of chalk and flintstone. Largely destabilized by an intense weathering and the Channel sea erosion, small and large rockfalls are regularly observed and contribute to retrogressive cliff processes. During autumn 2012, cliff and intertidal topographies have been acquired with a Terrestrial Laser Scanner (TLS) and a Mobile Laser Scanner (MLS), coupled with seafloor bathymetries realized with a multibeam echosounder (MBES). MLS is a recent development of laser scanning based on the same theoretical principles of aerial LiDAR, but using smaller, cheaper and portable devices. The MLS system, which is composed by an accurate dynamic positioning and orientation (INS) devices and a long range LiDAR, is mounted on a marine vessel; it is then possible to quickly acquire in motion georeferenced LiDAR point clouds with a resolution of about 15 cm. For example, it takes about 1 h to scan of shoreline of 2 km long. MLS is becoming a promising technique supporting erosion and rockfall assessments along the shores of lakes, fjords or seas. In this study, the MLS system used to acquire cliffs and intertidal areas of the Cap d'Ailly was composed by the INS Applanix POS-MV 320 V4 and the LiDAR Optech Ilirs LR. On the same day, three MLS scans with large overlaps (J1, J21 and J3) have been performed at ranges from 600 m at 4 knots (low tide) up to 200 m at 2.2 knots (up tide) with a calm sea at 2.5 Beaufort (small wavelets). Mean scan resolutions go from 26 cm for far scan (J1) to about 8.1 cm for close scan (J3). Moreover, one TLS point cloud on this test site has been acquired with a mean resolution of about 2.3 cm, using a Riegl LMS Z390i. In order to quantify the reliability of the methodology, comparisons between scans have been realized with the software Polyworks™, calculating shortest distances between points of one cloud and the interpolated surface of the reference point cloud. A Mat

  19. Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDI{sub vol})

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Cederlund, Kerstin; Aspelin, Peter; Brismar, Torkel B. [Intervention and Technology at Karolinska Institutet, Department of Clinical Science, Division of Medical Imaging and Technology, Stockholm (Sweden); Karolinska University Hospital in Huddinge, Department of Radiology, Stockholm (Sweden); Bjoerk, Jonas [FoU-centrum Skaane Skaanes Universitetssjukhus i Lund, Lund (Sweden); Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Lasarettet Trelleborg, Trelleborg (Sweden)

    2014-08-15

    To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index (CTDI{sub vol}) and body weight (BW). One hundred patients referred for standard three-phase thoraco-abdominal MDCT examination were enrolled. BW was measured in the CT suite. Forty grams of iodine was administered intravenously (iodixanol 320 mg I/ml at 5 ml/s or iomeprol 400 mg I/ml at 4 ml/s) followed by a 50-ml saline flush. CTDI{sub vol} presented by the CT equipment during the parenchymal examination was recorded. The CM enhancement of the liver was defined as the attenuation HU of the liver parenchyma during the hepatic parenchymal phase minus the attenuation in the native phase. Liver parenchymal enhancement was negatively correlated to both CTDI{sub vol} (r = -0.60) and BW (r = -0.64), but the difference in correlation between those two was not significant. CTDI{sub vol} may replace BW when adjusting CM doses to body size. This makes it potentially feasible to automatically individualize CM dosage by CT. (orig.)

  20. Convective Influence and Transport Pathways Controlling the Tropical Distribution of Carbon Monoxide at 100 Hpa

    Science.gov (United States)

    Jensen, Eric; Bergman, John; Pfister, Leonard; Ueyama, Rei; Kinnison, Doug

    2014-01-01

    Trajectory calculations with convective influence diagnosed from geostationary-satellite cloud measurements are used to evaluate the relative importance of different Tropical Tropopause Layer (TTL) transport pathways for establishing the distribution of carbon monoxide (CO) at 100 hPa as observed by the Microwave Limb Sounder (MLS) on board the Aura satellite. Carbon monoxide is a useful tracer for investigating TTL transport and convective influence because the CO lifetime is comparable to the time require for slow ascent through the TTL (a couple of months). Offline calculations of TTL radiative heating are used to determine the vertical motion field. The simple trajectory model does a reasonable job of reproducing the MLS CO distributions during Boreal wintertime and summertime. The broad maximum in CO concentration over the Pacific is primarily a result of the strong radiative heating (indicating upward vertical motion) associated with the abundant TTL cirrus in this region. Sensitivity tests indicate that the distinct CO maximum in the Asian monsoon anticyclone is strongly impacted by extreme convective systems with detrainment of polluted air above 360 K potential temperature. The relative importance of different CO source regions will also be discussed.

  1. Applications of an energy-dispersive pnCCD for X-ray reflectivity: Investigation of interdiffusion in Fe-Pt multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Abboud, Ali; Send, Sebastian; Pietsch, Ullrich [Universitaet Siegen, FB Physik, Walter-Flex-Strasse 3, 57072 Siegen (Germany); Hartmann, Robert [PNSensor GmbH, Muenchen (Germany); Strueder, Lothar [Universitaet Siegen, FB Physik, Walter-Flex-Strasse 3, 57072 Siegen (Germany); Planck-Institut fuer extraterrestrische Physik (MPE), Muenchen (Germany); MPI Halbleiterlabor, Muenchen (Germany); Savan, Alan; Ludwig, Alfred [Ruhr-Universitaet Bochum, Bochum (Germany); Zotov, Nikolay [Forschungszentrum Juelich, Juelich (Germany)

    2011-11-15

    A frame store pn-junction CCD (pnCCD) detector was applied to study thermally induced interdiffusion in Fe/Pt thin film multilayers (MLs) in a temperature range between 300 and 585 K. Based on the energy resolution of the detector the reflectivity was measured simultaneously in a spectral range between 8 keV < E < 20 keV including the Pt L-edge energies close to 11.5 keV. Above T = 533 K we find a strong drop of intensities at 1st and 2nd order ML Bragg peak interpreted by mutual interdiffusion. Considering a simulated model of interdiffusion it has been found that the concentration of iron that diffuses into the platinum sub layers is higher than that of platinum into iron. The time dependence of inter diffusion was also calculated in the range of 533-568 K and was described by the Arrhenius equation D(T) = D{sub 0} exp(-H{sub a}/k{sub B}T). The activation energy for the MLs used [Fe 1.7 nm/Pt 2 nm]{sub 50} was found to be 0.94 {+-} 0.22 eV. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  2. A Voxel-Based Method for Automated Identification and Morphological Parameters Estimation of Individual Street Trees from Mobile Laser Scanning Data

    Directory of Open Access Journals (Sweden)

    Hongxing Liu

    2013-01-01

    Full Text Available As an important component of urban vegetation, street trees play an important role in maintenance of environmental quality, aesthetic beauty of urban landscape, and social service for inhabitants. Acquiring accurate and up-to-date inventory information for street trees is required for urban horticultural planning, and municipal urban forest management. This paper presents a new Voxel-based Marked Neighborhood Searching (VMNS method for efficiently identifying street trees and deriving their morphological parameters from Mobile Laser Scanning (MLS point cloud data. The VMNS method consists of six technical components: voxelization, calculating values of voxels, searching and marking neighborhoods, extracting potential trees, deriving morphological parameters, and eliminating pole-like objects other than trees. The method is validated and evaluated through two case studies. The evaluation results show that the completeness and correctness of our method for street tree detection are over 98%. The derived morphological parameters, including tree height, crown diameter, diameter at breast height (DBH, and crown base height (CBH, are in a good agreement with the field measurements. Our method provides an effective tool for extracting various morphological parameters for individual street trees from MLS point cloud data.

  3. Is clinical intervention in the ultra high risk phase effective? A intervenção clínica na fase de ultra alto risco é eficaz?

    Directory of Open Access Journals (Sweden)

    Philip McGuire

    2011-10-01

    Full Text Available Recent research suggests that early intervention in psychosis might improve the chances of recovery and may even be able to prevent the onset of psychotic disorders. Clinical intervention in subjects at ultra high risk (UHR of psychosis can have three different objectives. The first aim is to improve the 'prodromal' symptoms and problems that subjects usually present with. The second is to reduce the risk of the subsequent onset of frank psychosis. The third objective is to minimize the delay before the initiation of antipsychotic treatment in the subgroup of UHR subjects that go on to develop a first episode of psychosis. Both pharmacological and psychological interventions appear to be effective in reducing the severity of presenting symptoms in UHR subjects. Clinical trials of the impact of these interventions on the risk of subsequent transition to psychosis have been positive, but have involved small samples, and thus the issue of whether the effects persist in the long term remains to be determined. The monitoring of UHR subjects for the first signs of frank psychosis is an effective means of reducing the delay between the onset of the first episode and the start of antipsychotic treatment. Follow-up studies are required to test whether the reduction in this delay leads to an improved long term outcome. To date, the majority of the interventions that have been used in UHR subjects, such as case management, antipsychotic medication, and cognitive behavior therapy have previously been employed in patients with established psychosis. However, it is possible that treatments that are not normally used in patients with psychotic disorders may prove effective when applied at this stage.Estudos recentes sugerem que a intervenção precoce na psicose poderia melhorar as chances de recuperação e inclusive evitar o início de transtornos psicóticos. A intervenção cl��nica para indivíduos em ultra alto risco (UAR de psicose pode ter tr

  4. Towards a NNORSY Ozone Profile ECV from European Nadir UV/VIS Measurements

    Science.gov (United States)

    Felder, Martin; Kaifel, Anton; Huckle, Roger

    2010-12-01

    The Neural Network Ozone Retrieval System (NNORSY) has been adapted and applied to several different satellite instruments, including the backscatter UV/VIS instruments ERS2-GOME, SCIAMACHY and METOP-GOME-2. The retrieved long term ozone field hence spans the years 1995 till now. To provide target data for training the neural networks, the lower parts of the atmosphere are sampled by ozone sondes from the WOUDC and SHADOZ data archives. Higher altitudes are covered by a variety of limb-sounding instruments, including the SAGE and POAM series, HALOE, ACE-FTS and AURA-MLS. In this paper, we show ozone profile time series over the entire time range to demonstrate the "out-of-the-box" consistency and homogeneity of our data across the three different nadir sounders, i.e. without any kind of tuning applied. These features of Essential Climate Variable (ECV) datasets [1] also lie at the heart of the recently announced ESA Climate Change Initiative, to which we hope to contribute in the near future.

  5. Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography

    International Nuclear Information System (INIS)

    Seifarth, Harald; Puesken, Michael; Wienbeck, Susanne; Wessling, Johannes; Maintz, David; Heindel, Walter; Juergens, Kai-Uwe; Kalafut, John F.

    2009-01-01

    The aim of this study was to determine whether individually tailored protocols for the injection of contrast medium (CM) result in higher and more homogeneous vascular attenuation throughout the coronary arteries at coronary CT angiography compared with conventional injection protocols using fixed injection parameters. Of 120 patients included in the study, 80 patients were randomized into two groups. Group 1 received 80 mL of CM at 6 mL/s. For group 2 injection parameters were individually adjusted to patient weight, the duration of CT data acquisition, and attenuation parameters following a test bolus. In the control group (group 3) the volume of CM was adjusted to the duration of CT data acquisition and injected at 5 mL/s. Attenuation was measured in the proximal, middle, and distal right coronary artery (RCA), in the proximal and middle left anterior descending artery (LAD), and in cranial and caudal sections of both ventricles. Patient parameters, scan delay, and scan duration did not differ significantly between the groups. Mean CM volume was 82.5 mL (flow rate 5.1 mL/s) in group 2 and 73.5 mL in group 3. Attenuation in both RCA and LAD was significantly higher for group 2 vs. group 3 (RCA: 414.9(±49.9)-396.1(±52.1) HU vs. 366.0(±64.3)-341.6(±72.5) HU; LAD: 398.9(±48.6)-364.6(±44.6) HU vs. 356.3(±69.5)-323.0(±67.2) HU). For group 1 vs. group 2 only attenuation in the distal RCA differed significantly: 396.1(±52.1) vs. 370.7(±70.5) HU. Individually tailored CM injection protocols yield higher attenuation, especially in the distal segments of the coronary vessels, compared with injection protocols using fixed injection parameters. (orig.)

  6. Early detection of metastases using whole-body MRI for initial staging and routine follow-up of myxoid liposarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Gorelik, Natalia; Reddy, Santhosh Mauvva Venkatesh; Powell, Thomas I. [McGill University Health Center, Department of Diagnostic Radiology, Montreal, Quebec (Canada); Turcotte, Robert E.; Goulding, Krista [McGill University Health Center, Division of Orthopaedic Surgery, Montreal, Quebec (Canada); Jung, Sungmi [McGill University Health Center, Department of Pathology, Montreal, Quebec (Canada); Alcindor, Thierry [McGill University Health Center, Gerald Bronfman Department of Oncology, Division of Medical Oncology, Montreal, Quebec (Canada)

    2018-03-15

    To define the role of whole-body MRI (WBMRI) for initial staging and routine follow-up of myxoid liposarcoma (MLS). A retrospective review of all the patients with MLS who underwent WBMRI for initial staging and routine follow-up at our institution between October 1, 2006, and September 30, 2016 was performed. Patient demographics, clinical presentation, imaging findings, tumor histology, and occurrence and location of metastatic disease were recorded. Thirty-three patients who underwent a total of 150 WBMRI examinations were included in the study. Nine patients (27%) were diagnosed with metastases between 0 and 60 months (median 10; interquartile range, 7-13) from the diagnosis of the primary tumor. The initial site of metastatic disease was extrapulmonary in all patients. Only two patients developed pulmonary metastases, which were diagnosed by CT chest 9 and 29 months after the diagnosis of extrapulmonary metastases. The first metastasis was diagnosed by WBMRI in seven patients (78%), by thoracic CT in one patient, and by abdominal CT in one patient. Eight of nine patients (89%) were asymptomatic at the time of diagnosis of the metastases. In seven patients (78%), WBMRI demonstrated metastases included within the field of view of, but occult on a contemporaneous CT scan. Our 10-year institutional experience demonstrates that WBMRI facilitates early detection of extrapulmonary MLS metastases before the onset of clinical symptoms and pulmonary metastases. WBMRI also depicts extrapulmonary metastases that are occult on CT scans. The current surveillance strategies are insufficient for screening for extrapulmonary MLS metastases. (orig.)

  7. Independent validation of the MMPI-2-RF Somatic/Cognitive and Validity scales in TBI Litigants tested for effort.

    Science.gov (United States)

    Youngjohn, James R; Wershba, Rebecca; Stevenson, Matthew; Sturgeon, John; Thomas, Michael L

    2011-04-01

    The MMPI-2 Restructured Form (MMPI-2-RF; Ben-Porath & Tellegen, 2008) is replacing the MMPI-2 as the most widely used personality test in neuropsychological assessment, but additional validation studies are needed. Our study examines MMPI-2-RF Validity scales and the newly created Somatic/Cognitive scales in a recently reported sample of 82 traumatic brain injury (TBI) litigants who either passed or failed effort tests (Thomas & Youngjohn, 2009). The restructured Validity scales FBS-r (restructured symptom validity), F-r (restructured infrequent responses), and the newly created Fs (infrequent somatic responses) were not significant predictors of TBI severity. FBS-r was significantly related to passing or failing effort tests, and Fs and F-r showed non-significant trends in the same direction. Elevations on the Somatic/Cognitive scales profile (MLS-malaise, GIC-gastrointestinal complaints, HPC-head pain complaints, NUC-neurological complaints, and COG-cognitive complaints) were significant predictors of effort test failure. Additionally, HPC had the anticipated paradoxical inverse relationship with head injury severity. The Somatic/Cognitive scales as a group were better predictors of effort test failure than the RF Validity scales, which was an unexpected finding. MLS arose as the single best predictor of effort test failure of all RF Validity and Somatic/Cognitive scales. Item overlap analysis revealed that all MLS items are included in the original MMPI-2 Hy scale, making MLS essentially a subscale of Hy. This study validates the MMPI-2-RF as an effective tool for use in neuropsychological assessment of TBI litigants.

  8. Impact of land convection on troposphere-stratosphere exchange in the tropics

    Directory of Open Access Journals (Sweden)

    P. Ricaud

    2007-11-01

    Full Text Available The mechanism of troposphere-stratosphere exchange in the tropics was investigated from space-borne observations of the horizontal distributions of tropospheric-origin long-lived species, nitrous oxide (N2O, methane (CH4 and carbon monoxide (CO, from 150 to 70 hPa in March-April-May by the ODIN/Sub-Millimeter Radiometer (SMR, the Upper Atmosphere Research Satellite (UARS/Halogen Occultation Experiment (HALOE and the TERRA/Measurements Of Pollution In The Troposphere (MOPITT instruments in 2002–2004, completed by recent observations of the AURA/Microwave Limb Sounder (MLS instrument during the same season in 2005. The vertical resolution of the satellite measurements ranges from 2 to 4 km. The analysis has been performed on isentropic surfaces: 400 K (lower stratosphere for all the species and 360 K (upper troposphere only for CO. At 400 K (and 360 K for CO, all gases show significant longitudinal variations with peak-to-trough values of ~5–11 ppbv for N2O, 0.07–0.13 ppmv for CH4, and ~10 ppbv for CO (~40 ppbv at 360 K. The maximum amounts are primarily located over Africa and, depending on the species, secondary more or less pronounced maxima are reported above northern South America and South-East Asia. The lower stratosphere over the Western Pacific deep convective region where the outgoing longwave radiation is the lowest, the tropopause the highest and the coldest, appears as a region of minimum concentration of tropospheric trace species. The possible impact on trace gas concentration at the tropopause of the inhomogeneous distribution and intensity of the sources, mostly continental, of the horizontal and vertical transports in the troposphere, and of cross-tropopause transport was explored with the MOCAGE Chemistry Transport Model. In the simulations, significant longitudinal variations were found on the medium-lived CO (2-month lifetime with peak-to-trough value of ~20 ppbv at 360 K and

  9. Retrospective, nonrandomized controlled study on autoadjusting, dual-pressure positive airway pressure therapy for a consecutive series of complex insomnia disorder patients

    Directory of Open Access Journals (Sweden)

    Krakow B

    2017-03-01

    Full Text Available Barry Krakow,1–3 Natalia D McIver,1,2 Victor A Ulibarri,1,2 Michael R Nadorff4,5 1Sleep & Human Health Institute, 2Maimonides Sleep Arts & Sciences, Ltd, Albuquerque, 3Los Alamos Medical Center, Los Alamos, NM, 4Department of Psychology, Mississippi State University, Mississippi, MS, 5Department of Psychiatry and Behavioral Sciences, Baylor College of Medicine, Houston, TX, USA Purpose: Emerging evidence shows that positive airway pressure (PAP treatment of obstructive sleep apnea (OSA and upper airway resistance syndrome (UARS in chronic insomnia patients (proposed “complex insomnia” disorder leads to substantial decreases in insomnia severity. Although continuous PAP (CPAP is the pressure mode most widely researched, intolerance to fixed pressurized air is rarely investigated or described in comorbidity patients. This retrospective study examined dual pressure, autoadjusting PAP modes in chronic, complex insomnia disorder patients.Patients and methods: Chronic insomnia disorder patients (mean [SD] insomnia severity index [ISI] =19.11 [3.34] objectively diagnosed with OSA or UARS and using either autobilevel PAP device or adaptive servoventilation (ASV device after failing CPAP therapy (frequently due to intolerance to pressurized air, poor outcomes, or emergence of CSA were divided into PAP users (≥20 h/wk and partial users (<20 h/wk for comparison. Subjective and objective baseline and follow-up measures were analyzed.Results: Of the 302 complex insomnia patients, PAP users (n=246 averaged 6.10 (1.78 nightly hours and 42.71 (12.48 weekly hours and partial users (n=56 averaged 1.67 (0.76 nightly hours and 11.70 (5.31 weekly hours. For mean (SD decreases in total ISI scores, a significant (group × time interaction was observed (F[1,300]=13.566; P<0.0001 with PAP users (–7.59 [5.92]; d=1.63 showing superior results to partial users (-4.34 [6.13]; d=0.81. Anecdotally, patients reported better tolerability with advanced PAP

  10. UARS Halogen Occultation Experiment (HALOE) Level 2 V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The HALOE home page on the WWW is http://haloe.gats-inc.com/home/index.php The Halogen Occultation Experiment (HALOE) on NASA's Upper Atmosphere Research Satellite...

  11. Validation of ACE-FTS N2O measurements

    Directory of Open Access Journals (Sweden)

    G. P. Stiller

    2008-08-01

    Full Text Available The Atmospheric Chemistry Experiment (ACE, also known as SCISAT, was launched on 12 August 2003, carrying two instruments that measure vertical profiles of atmospheric constituents using the solar occultation technique. One of these instruments, the ACE Fourier Transform Spectrometer (ACE-FTS, is measuring volume mixing ratio (VMR profiles of nitrous oxide (N2O from the upper troposphere to the lower mesosphere at a vertical resolution of about 3–4 km. In this study, the quality of the ACE-FTS version 2.2 N2O data is assessed through comparisons with coincident measurements made by other satellite, balloon-borne, aircraft, and ground-based instruments. These consist of vertical profile comparisons with the SMR, MLS, and MIPAS satellite instruments, multiple aircraft flights of ASUR, and single balloon flights of SPIRALE and FIRS-2, and partial column comparisons with a network of ground-based Fourier Transform InfraRed spectrometers (FTIRs. Between 6 and 30 km, the mean absolute differences for the satellite comparisons lie between −42 ppbv and +17 ppbv, with most within ±20 ppbv. This corresponds to relative deviations from the mean that are within ±15%, except for comparisons with MIPAS near 30 km, for which they are as large as 22.5%. Between 18 and 30 km, the mean absolute differences for the satellite comparisons are generally within ±10 ppbv. From 30 to 60 km, the mean absolute differences are within ±4 ppbv, and are mostly between −2 and +1 ppbv. Given the small N2O VMR in this region, the relative deviations from the mean are therefore large at these altitudes, with most suggesting a negative bias in the ACE-FTS data between 30 and 50 km. In the comparisons with the FTIRs, the mean relative differences between the ACE-FTS and FTIR partial columns (which cover a mean altitude range of 14 to 27 km are within ±5.6% for eleven of the twelve contributing stations. This mean relative difference is negative at ten stations

  12. The roles of convection, extratropical mixing, and in-situ freeze-drying in the Tropical Tropopause Layer

    Directory of Open Access Journals (Sweden)

    W. G. Read

    2008-10-01

    Full Text Available Mechanisms for transporting and dehydrating air across the tropical tropopause layer (TTL are investigated with a conceptual two dimensional (2-D model. The 2-D TTL model combines the Holton and Gettelman cold trap dehydration mechanism (Holton and Gettelman, 2001 with the two column convection model of Folkins and Martin (2005. We investigate 3 possible transport scenarios through the TTL: 1 slow uniform ascent across the level of zero radiative heating without direct convective mixing, 2 convective mixing of H2O vapor at 100% relative humidity with respect to ice (RHi with no ice retention, and 3 convective mixing of extremely subsaturated air (100% RHi following the moist adiabatic temperature above the level of neutral buoyancy with sufficient ice retention such that total H2O is 100%RHi. The three mechanisms produce similar seasonal cycles for H2O that are in good quantitative agreement with the Aura Microwave Limb Sounder (MLS measurements. We use Aura MLS measurement of CO and Atmospheric Chemistry Experiment-Fourier Transform Spectrometer measurement of HDO to distinguish among the transport mechanisms. Model comparisons with the observations support the view that H2O is predominantly controlled by regions having the lowest cold point tropopause temperature but the trace species CO and HDO support the convective mixing of dry air and lofted ice. The model provides some insight into the processes affecting the long term trends observed in stratospheric H2O.

  13. Heart Rate Variability and Cardiovascular Reactivity in Panic Disorder

    Science.gov (United States)

    1999-04-01

    Park, for his patience and personal assistance in setting up and operating the Vagal Tone Monitor. Io addition, I am grateful for the technical and...causes many patients to present initially to an emergency room or physician’s office upon onset of a panic attack (Beitman, Mukeiji, Aaker & Basha et...places make you afraid?" IIAre you considered a nervous person ?" UAre you constantly keyed up and jittery?" "Do you often become suddenly scared for

  14. High resolution mapping of riffle-pool dynamics based on ADCP and close-range remote sensing data

    Science.gov (United States)

    Salmela, Jouni; Kasvi, Elina; Alho, Petteri

    2017-04-01

    Present development of mobile laser scanning (MLS) and close-range photogrammetry with unmanned aerial vehicle (UAV) enable us to create seamless digital elevation models (DEMs) of the riverine environment. Remote-controlled flow measurement platforms have also improved spatio-temporal resolution of the flow field data. In this study, acoustic Doppler current profiler (ADCP) attached to remote-controlled mini-boat, UAV-based bathymetry and MLS techniques were utilized to create the high-resolution DEMs of the river channel. These high-resolution measurements can be used in many fluvial applications such as computational fluid dynamics, channel change detection, habitat mapping or hydro-electric power plant planning. In this study we aim: 1) to analyze morphological changes of river channel especially riffle and pool formations based on fine-scale DEMs and ADCP measurements, 2) to analyze flow fields and their effect on morphological changes. The interest was mainly focused on reach-scale riffle-pool dynamics within two-year period of 2013 and 2014. The study was performed in sub-arctic meandering Pulmankijoki River located in Northern Finland. The river itself has shallow and clear water and sandy bed sediment. Discharge remains typically below 10 m3s-1 most of the year but during snow melt period in spring the discharge may exceed 70 m3s-1. We compared DEMs and ADCP measurements to understand both magnitude and spatio-temporal change of the river bed. Models were accurate enough to study bed form changes and locations and persistence of riffles and pools. We analyzed their locations with relation to flow during the peak and low discharge. Our demonstrated method has improved significantly spatio-temporal resolution of riverine DEMs compared to other cross-sectional and photogrammetry based models. Together with flow field measurements we gained better understanding of riverbed-water interaction

  15. Merged ozone profiles from four MIPAS processors

    Science.gov (United States)

    Laeng, Alexandra; von Clarmann, Thomas; Stiller, Gabriele; Dinelli, Bianca Maria; Dudhia, Anu; Raspollini, Piera; Glatthor, Norbert; Grabowski, Udo; Sofieva, Viktoria; Froidevaux, Lucien; Walker, Kaley A.; Zehner, Claus

    2017-04-01

    The Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) was an infrared (IR) limb emission spectrometer on the Envisat platform. Currently, there are four MIPAS ozone data products, including the operational Level-2 ozone product processed at ESA, with the scientific prototype processor being operated at IFAC Florence, and three independent research products developed by the Istituto di Fisica Applicata Nello Carrara (ISAC-CNR)/University of Bologna, Oxford University, and the Karlsruhe Institute of Technology-Institute of Meteorology and Climate Research/Instituto de Astrofísica de Andalucía (KIT-IMK/IAA). Here we present a dataset of ozone vertical profiles obtained by merging ozone retrievals from four independent Level-2 MIPAS processors. We also discuss the advantages and the shortcomings of this merged product. As the four processors retrieve ozone in different parts of the spectra (microwindows), the source measurements can be considered as nearly independent with respect to measurement noise. Hence, the information content of the merged product is greater and the precision is better than those of any parent (source) dataset. The merging is performed on a profile per profile basis. Parent ozone profiles are weighted based on the corresponding error covariance matrices; the error correlations between different profile levels are taken into account. The intercorrelations between the processors' errors are evaluated statistically and are used in the merging. The height range of the merged product is 20-55 km, and error covariance matrices are provided as diagnostics. Validation of the merged dataset is performed by comparison with ozone profiles from ACE-FTS (Atmospheric Chemistry Experiment-Fourier Transform Spectrometer) and MLS (Microwave Limb Sounder). Even though the merging is not supposed to remove the biases of the parent datasets, around the ozone volume mixing ratio peak the merged product is found to have a smaller (up to 0.1 ppmv

  16. Structural oxidation state studies of the manganese cluster in the oxygen evolving complex of photosystem II

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Wenchuan [Univ. of California, Berkeley, CA (United States)

    1994-11-01

    X-ray absorption spectroscopy (XAS) was performed on Photosystem II (PSII)-enriched membranes prepared from spinach to explore: (1) the correlation between structure and magnetic spin state of the Mn cluster in the oxygen evolving complex (OEC) in the S2 state; and (2) the oxidation state changes of the Mn cluster in the flash-induced S-states. The structure of the Mn cluster in the S2 state with the g~4 electron paramagnetic resonance (EPR) signal (S2-g4 state) was compared with that in the S2 state with multiline signal (S2-MLS state) and the S1 state. The S2-g4 state has a higher XAS inflection point energy than that of the S1 state, indicating the oxidation of Mn in the advance from the S1 to the S2-g4 state. Differences in the edge shape and in the extended X-ray absorption fine structure (EXAFS) show that the structure of the Mn cluster in the S2-g4 state is different from that in the S2-MLS or the S1 state. In the S2-g4 state, the second shell of backscatterers from the Mn absorber contains two Mn-Mn distances of 2.73 Å and 2.85 Å. Very little distance disorder exists in the second shell of the S1 or S2-MLS states. The third shell of the S2-g4 state at about 3.3 Å also contains increased heterogeneity relative to that of the S2-MLS or the S1 state. Various S-states were prepared at room-temperature by saturating, single-turnover flashes. The flash-dependent oscillation in the amplitude of the MLS was used to characterize the S-state composition and to construct "pure" S-state Mn K-edge spectra. The edge position shifts to higher energy by 1.8 eV upon the S1 → S2 transition.

  17. Urethral sensation following reconstructive pelvic surgery.

    Science.gov (United States)

    Abernethy, M G; Davis, C; Lowenstein, L; Mueller, E R; Brubaker, L; Kenton, K

    2014-11-01

    Most urethral neuromuscular function data focus on efferent rather than afferent innervation. We aimed to determine if changes exist in urethral afferent nerve function before and after reconstructive pelvic surgery (RPS). Secondarily, we compared afferent urethral innervation in women with and without stress urinary incontinence undergoing RPS. Participants underwent current perception threshold (CPT) and urethral anal reflex (UAR) testing prior to surgery and again post-operatively. Wilcoxon signed ranked test and Spearman's correlations were used and all tests were two-sided. p = 0.05 was considered to indicate statistical significance. Urethral CPT thresholds increased significantly after RPS, consistent with decreased urethral afferent function. Pre-operative urethral CPT thresholds at 5 and 250 Hz were lower in SUI women (10 [IQR 5-29], 40 [32-750]) compared with continent women (63 [14-99], 73 [51-109]; p = 0.45, p = 0.020), signifying increased urethral sensation or easier activation of urethral afferents in SUI women. Reconstructive pelvic surgery is associated with a short-term deleterious impact on urethral afferent function, as demonstrated by the higher levels of stimuli required to activate urethral afferent nerves (decreased urethral sensation) immediately after RPS. Women with SUI required lower levels of stimuli to activate urethral afferent nerves prior to RPS, although UAR latencies were similar regardless of concomitant SUI.

  18. Evaluation of renal allograft with 99mTc-mononuclear leukocytes

    International Nuclear Information System (INIS)

    Souza, S.A.L.; Oliveira, H.S.; Goncalves, R.T.; Pontes, D.S.; Fonseca, L.B.M.; Gutfilen, B.

    2002-01-01

    Aim: Because kidney biopsy is an invasive procedure that carries a small but significant risk of major complications, a noninvasive test that detects rejection before it is clinically apparent is very much needed. The reversibility of acute rejection is related to the promptness with which treatment is begun. Here we show the evaluation of rejection in the first week post-transplant with 99m Tc-mononuclear leukocyte scintigraphy (99mTc-MLS). Materials and Methods: 70 patients submitted to renal transplant at the Hospital Universitario Clementino Fraga Filho (HUCFF/UFRJ) underwent 99m Tc-MLS at the 1st and 5th post-transplant days. The labeled cells were administered (444MBq) and scans were carried out 3 and 24h post injection. A region of interest (ROI) was drawn at the allograft image and statistics compared between the 3 and 24h images. Percentages above 15% in the 24h image relating to the 3h image were considered abnormal and suspect of rejection. 25 of the 70 patients rejected the renal allograft in the 1st week post-transplant. Results: 99m Tc-MLS has detected rejection in 20 of the 25 patients. Color Doppler was also carried out in all the patients and has detected 16 rejections. Sensitivity and specificity were 80% and 100% for scintigraphy and 64% and 100% for Ultrasound. 99m Tc-MLS is more sensitive in humoral rejection than color Doppler. The latter is better to identify the vascular rejection. Conclusion: In order to evaluate renal allograft and improve the rejection diagnosis the combination of both techniques should be applied. More studies are now in progress

  19. In vivo breast sound-speed imaging with ultrasound tomography

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Li, Cuiping [KARMANOS CANCER INSTITUTE; Duric, Neb [KARMANOS CANCER INSTITUTE; Littrup, Peter [KARMONOS CANCER INSTITUTE

    2009-01-01

    We discuss a bent-ray ultrasound tomography algorithm with total-variation (TV) regularization. We have applied this algorithm to 61 in vivo breast datasets collected with our in-house clinical prototype for imaging sound-speed distributions in the breast. Our analysis showed that TV regularization could preserve sharper lesion edges than the classic Tikhonov regularization. Furthermore, the image quality of our TV bent-ray sound-speed tomograms was superior to that of the straight-ray counterparts for all types of breasts within BI-RADS density categories 1-4. For all four breast types from fatty to dense, the improvements for average sharpness (in the unit of (m{center_dot} s) {sup -1}) of lesion edges in our TV bent-ray tomograms are between 2.1 to 3.4 fold compared to the straight ray tomograms. Reconstructed sound-speed tomograms illustrated that our algorithm could successfully image fatty and glandular tissues within the breast. We calculated the mean sound-speed values for fatty tissue and breast parenchyma as 1422 {+-} 9 mls (mean{+-} SD) and1487 {+-} 21 mls, respectively. Based on 32 lesions in a cohort of 61 patients, we also found that the mean sound-speed for malignant breast lesions (1548{+-}17 mls) was higher, on average, than that of benign ones (1513{+-}27 mls) (one-sided p

  20. Indonesian Fire Activity and Smoke Pollution in 2015 Show Persistent Nonlinear Sensitivity to El Niño-induced Drought

    Science.gov (United States)

    Field, Robert D.; van der Werf, Guido R.; Fanin, Thierry; Fetzer, Eric; Fuller, Ryan; Jethva, Hiren; Levy, Robert; Livesey, Nathaniel; Luo, Ming; Torres, Omar; hide

    2016-01-01

    The 2015 fire season and related smoke pollution in Indonesia was more severe than the major 2006 episode, making it the most severe season observed by the NASA Earth Observing System satellites that go back to the early 2000s, namely active fire detections from the Terra and Aqua Moderate Resolution Imaging Spectroradiometers (MODIS), MODIS aerosol optical depth, Terra Measurement of Pollution in the Troposphere (MOPITT) carbon monoxide (CO), Aqua Atmospheric Infrared Sounder (AIRS) CO, Aura Ozone Monitoring Instrument (OMI) aerosol index, and Aura Microwave Limb Sounder (MLS) CO. The MLS CO in the upper troposphere showed a plume of pollution stretching from East Africa to the western Pacific Ocean that persisted for two months. Longer-term records of airport visibility in Sumatra and Kalimantan show that 2015 ranked after 1997 and alongside 1991 and 1994 as among the worst episodes on record. Analysis of yearly dry season rainfall from the Tropical Rainfall Measurement Mission (TRMM) and rain gauges shows that, due to the continued use of fire to clear and prepare land on degraded peat, the Indonesian fire environment continues to have non-linear sensitivity to dry conditions during prolonged periods with less than 4mmday of precipitation, and this sensitivity appears to have increased over Kalimantan. Without significant reforms in land use and the adoption of early warning triggers tied to precipitation forecasts, these intense fire episodes will re-occur during future droughts, usually associated with El Nio events.

  1. Possibility of a quasi-liquid layer of As on GaAs substrate grown by MBE as observed by enhancement of Ga desorption at high As pressure

    Science.gov (United States)

    Asai, K.; Feng, J. M.; Vaccaro, P. O.; Fujita, K.; Ohachi, T.

    2000-06-01

    The As vapor pressure dependence of the Ga desorption rate during molecular beam epitaxy (MBE) growth on GaAs( n11)A ( n=1-4 hereafter) substrates was studied by photoluminescence (PL) measurements at 12 K for undoped AlGaAs/GaAs asymmetric double quantum wells (ADQWs). Reflection high energy electron diffraction (RHEED) oscillation measurements on a GaAs(100) surface were also used. Two K-cells of As solid sources (corresponding to beam equivalent pressures (BEPs) of 9.0×10 -6 and 4.5×10 -5 Torr) were used to change the As pressure rapidly. The Ga flux and substrate temperature were kept constant at 0.76 ML/s and 12 K, respectively, while the As flux changed from 7.6 (BEP 9.0×10 -6 Torr) to 32 ML/s (4.5×10 -5 Torr). With increasing As pressure, two separated PL peaks for the wide well (WW) of high index substrates were observed. This peak separation is attributed to a reduced well depth from an increasing Ga desorption rate. The energy differences of the PL peak depending on the off-angle from (111)A to (100) plane indicates an orientation-dependent Ga desorption rate. Moreover, amongst all ( n11)A and (100) planes, the Ga desorption rate was smallest from the (111)A surface. The increase of Ga desorption from the surface at high As pressures probably arose from an increasing coverage with a quasi-liquid layer (QLL).

  2. RECCURENT LARYNGEAL PAPILLOMA

    Directory of Open Access Journals (Sweden)

    Nyilo Purnami

    2012-01-01

    Full Text Available A case of respiratory papillomatosis was reported. The patient suffered from the disease since eight months old with chief complaint progressive hoarseness and dyspnea. It was diagnosed with respiratory papillomatosis and scheduled for performing tracheotomy and continued with the first microlaryngeal surgery (MLS. Decanulation was taken after 2nd surgery of removing papillomas. Finally was reported she got serial of surgery for 22 times during 18 years of age. It was costly and deteriorating quality of life. The problem remains persisted because of frequent recurrences and need for repetitive surgeries. Specimen biopsy for histologic examination was shown the signs of HPV infection, papilomatic coated squamous epithel with mild dysplasia and coilocytosis. The threatening of upper airway obstruction is the main important reason for patient's coming. The patency of airway assessed by Direct Laryngoscopy then the next treatment was decided with schedule of Micro Laryngeal Surgery (MLS. Finally the MLS treatment is just only for temporarily recovery. A further research to define the proper treatment in the future is required, especially for prevention of the diseases related to the viral causes of infection.

  3. Land-Based Mobile Laser Scanning Systems: a Review

    Science.gov (United States)

    Puente, I.; González-Jorge, H.; Arias, P.; Armesto, J.

    2011-09-01

    Mobile mapping has been using various photogrammetric techniques for many years. In recent years, there has been an increase in the number of mobile mapping systems using laser scanners available in the market, partially because of the improvement in GNSS/INS performance for direct georeferencing. In this article, some of the most important land-based mobile laser scanning (MLS) systems are reviewed. Firstly, the main characteristics of MLS systems vs. airborne (ALS) and terrestrial laser scanning (TLS) systems are compared. Secondly, a short overview of the mobile mapping technology is also provided so that the reader can fully grasp the complexity and operation of these devices. As we put forward in this paper, a comparison of different systems is briefly carried out regarding specifications provided by the manufacturers. Focuses on the current research are also addressed with emphasis on the practical applications of these systems. Most of them have been utilized for data collection on road infrastructures or building façades. This article shows that MLS technology is nowadays well established and proven, since the demand has grown to the point that there are several systems suppliers offering their products to satisfy this particular market.

  4. Two-dimensional Haeckelite NbS{sub 2}. A diamagnetic high-mobility semiconductor with Nb{sup 4+} ions

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Yandong; Kuc, Agnieszka; Jing, Yu; Heine, Thomas [Wilhelm-Ostwald-Institut fuer Physikalische und Theoretische Chemie, Universitaet Leipzig (Germany); Philipsen, Pier [Scientific Computing and Modelling NV, Amsterdam (Netherlands)

    2017-08-14

    In all known Group 5 transition-metal dichalcogenide monolayers (MLs), the metal centers carry a spin, and their ground-state phases are either metallic or semiconducting with indirect band gaps. Here, on grounds of first-principles calculations, we report that the Haeckelite polytypes 1S-NbX{sub 2} (X=S, Se, Te) are diamagnetic direct-band-gap semiconductors even though the Nb atoms are in the 4+ oxidation state. In contrast, 1S-VX{sub 2} MLs are antiferromagnetically coupled indirect-band-gap semiconductors. The 1S phases are thermodynamically and dynamically stable but of slightly higher energy than their 1H and 1T ML counterparts. 1S-NbX{sub 2} MLs are excellent candidates for optoelectronic applications owing to their small band gaps (between 0.5 and 1 eV). Moreover, 1S-NbS{sub 2} shows a particularly high hole mobility of 2.68 x 10{sup 3} cm{sup 2} V{sup -1} s{sup -1}, which is significantly higher than that of MoS{sub 2} and comparable to that of WSe{sub 2}. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Advanced Transport Operating Systems Program

    Science.gov (United States)

    White, John J.

    1990-01-01

    NASA-Langley's Advanced Transport Operating Systems Program employs a heavily instrumented, B 737-100 as its Transport Systems Research Vehicle (TRSV). The TRSV has been used during the demonstration trials of the Time Reference Scanning Beam Microwave Landing System (TRSB MLS), the '4D flight-management' concept, ATC data links, and airborne windshear sensors. The credibility obtainable from successful flight test experiments is often a critical factor in the granting of substantial commitments for commercial implementation by the FAA and industry. In the case of the TRSB MLS, flight test demonstrations were decisive to its selection as the standard landing system by the ICAO.

  6. Ab initio investigation of inversion in tetrahedral molecules of transition metals

    International Nuclear Information System (INIS)

    Musaev, D.G.; Boldyrev, A.I.

    1984-01-01

    Tetrahedral and plane square configurations of TiH 4 , TiF 4 , molecules and ScH 4 - , ScF 4 - anions are optimized in the frames of Hartree-Fock-Roothaan method with the bases of DZHD and DZRS type. Inversion barriers of tetrahedral molecules through plane sqUare configuration which make up 46; 70; 27 and 39 kcal/mol in TiH 4 , TiF 4 , SoH 4 - and ScF 4 - respectively are estimated. Correlation diagrams under inversion are analyzed

  7. Kalman Filter Chemical Data Assimilation: A Case Study in January 1992

    Science.gov (United States)

    Lary, D. J.; Khattatov, B.; Atlas, Robert; Mussa, H.

    2002-01-01

    This paper describes a Kalman filter chemical data assimilation system and its use for analysing a vertical atmospheric profile during January 1992. The vertical profile was at an equivalent PV latitude (phi(sub e)) of 55 deg S and consisted of 21 potential temperature (theta) levels spaced equally in log(theta) between 400 K and 2000 K. This equivalent latitude was chosen as it was well observed during January 1992 by instruments on board the Upper Atmosphere Research Satellite (UARS).

  8. Northern Hemisphere atmospheric influence of the solar proton events and ground level enhancement in January 2005

    Directory of Open Access Journals (Sweden)

    C. H. Jackman

    2011-07-01

    Full Text Available Solar eruptions in early 2005 led to a substantial barrage of charged particles on the Earth's atmosphere during the 16–21 January period. Proton fluxes were greatly increased during these several days and led to the production of HOx (H, OH, HO2 and NOx (N, NO, NO2, which then caused the destruction of ozone. We focus on the Northern polar region, where satellite measurements and simulations with the Whole Atmosphere Community Climate Model (WACCM3 showed large enhancements in mesospheric HOx and NOx constituents, and associated ozone reductions, due to these solar proton events (SPEs. The WACCM3 simulations show enhanced short-lived OH and HO2 concentrations throughout the mesosphere in the 60–82.5° N latitude band due to the SPEs for most days in the 16–21 January 2005 period, somewhat higher in abundance than those observed by the Aura Microwave Limb Sounder (MLS. These HOx enhancements led to huge predicted and MLS-measured ozone decreases of greater than 40 % throughout most of the northern polar mesosphere during the SPE period. Envisat Michelson Interferometer for Passive Atmospheric Sounding (MIPAS measurements of hydrogen peroxide (H2O2 show increases throughout the stratosphere with highest enhancements of about 60 pptv in the lowermost mesosphere over the 16–18 January 2005 period due to the solar protons. WACCM3 predictions indicate H2O2 enhancements over the same time period of about three times that amount. Measurements of nitric acid (HNO3 by both MLS and MIPAS show an increase of about 1 ppbv above background levels in the upper stratosphere during 16–29 January 2005. WACCM3 simulations show only minuscule HNO3 increases (<0.05 ppbv in the upper stratosphere during this time period. Polar mesospheric enhancements of NOx are computed to be greater than 50

  9. Roadside Multiple Objects Extraction from Mobile Laser Scanning Point Cloud Based on DBN

    Directory of Open Access Journals (Sweden)

    LUO Haifeng

    2018-02-01

    Full Text Available This paper proposed an novel algorithm for exploring deep belief network (DBN architectures to extract and recognize roadside facilities (trees,cars and traffic poles from mobile laser scanning (MLS point cloud.The proposed methods firstly partitioned the raw MLS point cloud into blocks and then removed the ground and building points.In order to partition the off-ground objects into individual objects,off-ground points were organized into an Octree structure and clustered into candidate objects based on connected component.To improve segmentation performance on clusters containing overlapped objects,a refining processing using a voxel-based normalized cut was then implemented.In addition,multi-view features descriptor was generated for each independent roadside facilities based on binary images.Finally,a deep belief network (DBN was trained to extract trees,cars and traffic pole objects.Experiments are undertaken to evaluate the validities of the proposed method with two datasets acquired by Lynx Mobile Mapper System.The precision of trees,cars and traffic poles objects extraction results respectively was 97.31%,97.79% and 92.78%.The recall was 98.30%,98.75% and 96.77% respectively.The quality is 95.70%,93.81% and 90.00%.And the F1 measure was 97.80%,96.81% and 94.73%.

  10. Movement of the cervix in after-loading brachytherapy: implications for designing external-beam radiotherapy boost fields.

    Science.gov (United States)

    Hombaiah, U; Blake, P; Bidmead, M

    2006-05-01

    Women with invasive carcinoma of the cervix treated by chemo-radiotherapy and brachytherapy may also receive a pelvic sidewall boost using a midline shield (MLS). The purpose of this study was to assess the usefulness of implanted gold grains in detecting the movement of the cervix caused by the insertion of low-dose-rate brachytherapy applicators, and its implications in designing the MLS. The medical records of 42 women with various stages of cervical carcinoma, who were treated by radical chemo-radiotherapy, were reviewed. All of these women underwent examination under anaesthesia (EUA) and a gold-grain insertion to demarcate the vaginal tumour extent, in the antero-posterior and lateral planes, before starting external-beam radiotherapy. The isocentric orthogonal films (simulator films) of external radiotherapy and brachytherapy were compared to assess the change in position of the gold grains and the consequences for the design of the MLS for parametrial and pelvic sidewall boosts. A significant shift in the position of the gold grains was noted in both the x (lateral) and the y (cranial/caudal) axes. The median shift of the midline, right and left lateral gold grains was 4.5, 5 and 7 mm in the x axis, whereas it was 10, 8 and 9.5 mm in the y axis, respectively. The median shift in the x and y axes was 5.5 and 9 mm, ranging from 1 to 40 mm and 1 to 45 mm, respectively. The gold grains were shifted cranially in 34 (80%) and laterally in 29 (69%) women. Thirty-two women (76.2%) received parametrial boost radiotherapy, of which 25 (59.5%) women had a customised, pear-shaped shield, and the remaining seven (16.7%) had a straight-sided, rectangular MLS. Four women (9.5%) relapsed locally, and three of them had been treated using a customised shield. In two of these four women, there was an absolute under-dosage of the central pelvis at the tip of the intra-uterine tube by 50% of the parametrial boost dose (5.4 Gy/3 fractions/3 days). Insertion of the gold grains

  11. Tunable Far Infrared Studies in Support of Stratospheric Measurements

    Science.gov (United States)

    Chance, Kelly V.; Park, K.; Nolt, I. G.; Evenson, K. M.

    2001-01-01

    This report summarizes research done under NASA Grant NAG5-4653. The research performed under this grant has been a collaboration between institutions including the Smithsonian Astrophysical Observatory, the National Institute of Standards and Technology, the University of Oregon, and the NASA Langley Research Center. The program has included fully line-resolved measurements of submillimeter and far infrared spectroscopic line parameters (pressure broadening coefficients and their temperature dependences, and line positions) for the analysis of field measurements of stratospheric constituents, far infrared database improvements, and studies for improved satellite measurements of the Earth's atmosphere. This research program is designed to enable the full utilization of spectra obtained in far infrared/submillimeter field measurements, such as FIRS-2, FILOS, IBEX, SLS, EosMLS, and proposed European Space Agency measurements of OH (e.g., PIRAMHYD and SFINX) for the retrieval of accurate stratospheric altitude profiles of key trace gases involved in ozone layer photochemistry. For the analysis of the spectra obtained in the stratosphere from far infrared measurements it is necessary to have accurate values of the molecular parameters (line positions, strengths, and pressure broadening coefficients) for the measured molecules and for possible interfering species. Knowledge of line positions is in increasingly good shape, with some notable exceptions. The increase in position information includes research that has been performed in the present program of research on HO2, H2O, H2O2, O3, HCl, HF, HBr, HI, CO, OH, and ClO. Examples where further line position studies are necessary include hot band and minor isotopomer lines of some of the major trace species (H2O, O3) and normal lines of some triatomic and larger molecules (NO2). Knowledge of strengths is in generally good shape, since most of the lines are from electric dipole transitions whose intensities are well

  12. Graduate and Post-MLS Study in Digital Libraries

    Science.gov (United States)

    Blummer, Barbara

    2005-01-01

    As librarians confront the Information Age, it is imperative that they remain aware of the issues that affect the profession. Traditional library skills are no longer adequate for maintaining a competitive edge in the field. Post-graduate education in digital libraries offers information professionals an opportunity to broaden their knowledge of…

  13. The Vertical Structure of Relative Humidity and Ozone in the Tropical Upper Troposphere: Intercomparisons Among In Situ Observations, A-Train Measurements and Large-Scale Models

    Science.gov (United States)

    Selkirk, Henry B.; Manyin, Michael; Douglass, Anne R.; Oman, Luke; Pawson, Steven; Ott, Lesley; Benson, Craig; Stolarski, Richard

    2010-01-01

    In situ measurements in the tropics have shown that in regions of active convection, relative humidity with respect to ice in the upper troposphere is typically close to saturation on average, and supersaturations greater than 20% are not uncommon. Balloon soundings with the cryogenic frost point hygrometer (CFH) at Costa Rica during northern summer, for example, show this tendency to be strongest between 11 and 15.5 km (345-360 K potential temperature, or approximately 250-120 hPa). this is the altitude range of deep convective detrainment. Additionally, simultaneous ozonesonde measurements show that stratospheric air (O3 greater than 150 ppbv) can be found as low as approximately 14 km (350 K/150 hPa). In contrast, results from northern winter show a much drier upper troposphere and little penetration of stratospheric air below the tropopause at 17.5 km (approximately 383 K). We show that these results are consistent with in situ measurements from the Measurement of Ozone and water vapor by Airbus In-service airCraft (MOZAIC) program which samples a wider, though still limited, range of tropical locations. To generalize to the tropics as a whole, we compare our insitu results to data from two A-Train satellite instruments, the Atmospheric Infrared Sounder (AIRS) and the Microwave Limb Sounder (MLS) on the Aqua and Aura satellites respectively. Finally, we examine the vertical structure of water vapor, relative humidity and ozone in the NASA Goddard MERRA analysis, an assimilation dataset, and a new version of the GEOS CCM, a free-running chemistry-climate model. We demonstrate that conditional probability distributions of relative humidity and ozone are a sensitive diagnostic for assessing the representation of deep convection and upper troposphere/lower stratosphere mixing processes in large-scale analyses and climate models.

  14. Validation of MIPAS IMK/IAA V5R_O3_224 ozone profiles

    Directory of Open Access Journals (Sweden)

    A. Laeng

    2014-11-01

    Full Text Available We present the results of an extensive validation program of the most recent version of ozone vertical profiles retrieved with the IMK/IAA (Institute for Meteorology and Climate Research/Instituto de Astrofísica de Andalucía MIPAS (Michelson Interferometer for Passive Atmospheric Sounding research level 2 processor from version 5 spectral level 1 data. The time period covered corresponds to the reduced spectral resolution period of the MIPAS instrument, i.e., January 2005–April 2012. The comparison with satellite instruments includes all post-2005 satellite limb and occultation sensors that have measured the vertical profiles of tropospheric and stratospheric ozone: ACE-FTS, GOMOS, HALOE, HIRDLS, MLS, OSIRIS, POAM, SAGE II, SCIAMACHY, SMILES, and SMR. In addition, balloon-borne MkIV solar occultation measurements and ground-based Umkehr measurements have been included, as well as two nadir sensors: IASI and SBUV. For each reference data set, bias determination and precision assessment are performed. Better agreement with reference instruments than for the previous data version, V5R_O3_220 (Laeng et al., 2014, is found: the known high bias around the ozone vmr (volume mixing ratio peak is significantly reduced and the vertical resolution at 35 km has been improved. The agreement with limb and solar occultation reference instruments that have a known small bias vs. ozonesondes is within 7% in the lower and middle stratosphere and 5% in the upper troposphere. Around the ozone vmr peak, the agreement with most of the satellite reference instruments is within 5%; this bias is as low as 3% for ACE-FTS, MLS, OSIRIS, POAM and SBUV.

  15. Recent Biomass Burning in the Tropics and Related Changes in Tropospheric Ozone

    Science.gov (United States)

    Ziemke; Chandra, J. R. S.; Duncan, B. N.; Schoeberl, M. R.; Torres, O.; Damon, M. R.; Bhartia, P. K.

    2009-01-01

    Biomass burning is an important source of chemical precursors of tropospheric ozone. In the tropics, biomass burning produces ozone enhancements over broad regions of Indonesia, Africa, and South America including Brazil. Fires are intentionally set in these regions during the dry season each year to clear cropland and to clear land for human/industrial expansion. In Indonesia enhanced burning occurs during dry El Nino conditions such as in 1997 and 2006. These burning activities cause enhancement in atmospheric particulates and trace gases which are harmful to human health. Measurements from the Aura Ozone Monitoring Instrument (OMI) and Microwave Limb Sounder (MLS) from October 2004-November 2008 are used to evaluate the effects of biomass burning on tropical tropospheric ozone. These measurements show sizeable decreases approx.15-20% in ozone in Brazil during 2008 compared to 2007 which we attribute to the reduction in biomass burning. Three broad biomass burning regions in the tropics (South America including Brazil, western Africa, and Indonesia) were analyzed in the context of OMI/MLS measurements and the Global Modeling Initiative (GMI) chemical transport model developed at Goddard Space Flight Center. The results indicate that the impact of biomass burning on ozone is significant within and near the burning regions with increases of approx.10-25% in tropospheric column ozone relative to average background concentrations. The model suggests that about half of the increases in ozone from these burning events come from altitudes below 3 km. Globally the model indicates increases of approx.4-5% in ozone, approx.7-9% in NO, (NO+NO2), and approx.30-40% in CO.

  16. [Experiences in the treatment of benign prostatic hyperplasia with high power potassium-titanyl-phosphate (KTP) laser].

    Science.gov (United States)

    Lipiński, Marek I; Peszyński-Drews, Cezary; Jeromin, Marek Z; Jeromin, Leszek M

    2006-01-01

    Benign prostatic hyperplasia (BPH) exist in about 70% men after 60 years old. High power KTP laser is a new tool for the treatment of BPH. 49 men were treated by photoselective vaporisation of the prostate (PVP) from August 2003 to May 2004. Thirty patients with follow-up period longer than 12 weeks (12 to 26 weeks) were analyzed. Preoperative prostate volume ranged from 31 to 136 cc. PSA range, estimated before treatment, was normal in all patients (pts). International Prostate Symptom Score (I-PSS) estimated before treatment was over 24 and Quality of Life (QoL) was over 3 in all pts. The maximum peak urinary flow (Qmax) before treatment ranged from 7.2 to 14.1 ml/s. One patient was catheterized with Foley catheter at the finish of the procedure. Two pts required catheterization in the first day after treatment. In two pts increasing of body temperature to 38 degrees C was observed in the first day after treatment. Twenty four hours after treatment haematuria required catheterization was observed in one patient. Seven days after treatment in 4 pts massive haematuria was observed (two required hospitalisation). In one patient because of urinary retention 4 weeks after PVP transurethral resection of the prostate was performed. Four weeks after PVP I-PSS decreased from 24 to 20 and after 12 weeks to 15. The Qmax increased and ranged from 11.3 ml/s to 17.1 ml/s 4 weeks after PVP and 12 weeks after PVP ranged from 15.1 to 22.8 ml/s. Photoselective vaporization of the prostate reduces I-PSS in all patients 12 weeks after procedure. Short follow-up period and a limited number of patients in study group cannot lead to ultimate conclusions. However the results encourage to undertaking further studies on PVP for the treatment of BPH.

  17. Development of a digital automatic control law for steep glideslope capture and flare

    Science.gov (United States)

    Halyo, N.

    1977-01-01

    A longitudinal digital guidance and control law for steep glideslopes using MLS (Microwave Landing System) data is developed for CTOL aircraft using modern estimation and control techniques. The control law covers the final approach phases of glideslope capture, glideslope tracking, and flare to touchdown for automatic landings under adverse weather conditions. The control law uses a constant gain Kalman filter to process MLS and body-mounted accelerometer data to form estimates of flight path errors and wind velocities including wind shear. The flight path error estimates and wind estimates are used for feedback in generating control surface commands. Results of a digital simulation of the aircraft dynamics and the guidance and control law are presented for various wind conditions.

  18. Irradiance Observations of SMM, Spacelab 1, UARS, and ATLAS Experiments

    Science.gov (United States)

    Willson, Richard

    1994-01-01

    Detection of intrinsic solar variability on the total flux level was made using results from the first active Radiometer Irradiance Monitor (ACRIM) experiment, launched on the Solar Maximum Mission (SMM)in early 1980.

  19. UARS Particle Environment Monitor (PEM) Level 3TP V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The Particle Environment Monitor (PEM) Level 3TP data product consists of daily, 65.536 second and 2.048 interval time-ordered, vertical profiles of electron and...

  20. Brain activation to negative stimuli mediates a relationship between adolescent marijuana use and later emotional functioning

    Directory of Open Access Journals (Sweden)

    Mary M. Heitzeg

    2015-12-01

    Full Text Available This work investigated the impact of heavy marijuana use during adolescence on emotional functioning, as well as the brain functional mediators of this effect. Participants (n = 40 were recruited from the Michigan Longitudinal Study (MLS. Data on marijuana use were collected prospectively beginning in childhood as part of the MLS. Participants were classified as heavy marijuana users (n = 20 or controls with minimal marijuana use. Two facets of emotional functioning—negative emotionality and resiliency (a self-regulatory mechanism—were assessed as part of the MLS at three time points: mean age 13.4, mean age 19.6, and mean age 23.1. Functional neuroimaging data during an emotion-arousal word task were collected at mean age 20.2. Negative emotionality decreased and resiliency increased across the three time points in controls but not heavy marijuana users. Compared with controls, heavy marijuana users had less activation to negative words in temporal, prefrontal, and occipital cortices, insula, and amygdala. Activation of dorsolateral prefrontal cortex to negative words mediated an association between marijuana group and later negative emotionality. Activation of the cuneus/lingual gyrus mediated an association between marijuana group and later resiliency. Results support growing evidence that heavy marijuana use during adolescence affects later emotional outcomes.

  1. Disease named entity recognition from biomedical literature using a novel convolutional neural network.

    Science.gov (United States)

    Zhao, Zhehuan; Yang, Zhihao; Luo, Ling; Wang, Lei; Zhang, Yin; Lin, Hongfei; Wang, Jian

    2017-12-28

    Automatic disease named entity recognition (DNER) is of utmost importance for development of more sophisticated BioNLP tools. However, most conventional CRF based DNER systems rely on well-designed features whose selection is labor intensive and time-consuming. Though most deep learning methods can solve NER problems with little feature engineering, they employ additional CRF layer to capture the correlation information between labels in neighborhoods which makes them much complicated. In this paper, we propose a novel multiple label convolutional neural network (MCNN) based disease NER approach. In this approach, instead of the CRF layer, a multiple label strategy (MLS) first introduced by us, is employed. First, the character-level embedding, word-level embedding and lexicon feature embedding are concatenated. Then several convolutional layers are stacked over the concatenated embedding. Finally, MLS strategy is applied to the output layer to capture the correlation information between neighboring labels. As shown by the experimental results, MCNN can achieve the state-of-the-art performance on both NCBI and CDR corpora. The proposed MCNN based disease NER method achieves the state-of-the-art performance with little feature engineering. And the experimental results show the MLS strategy's effectiveness of capturing the correlation information between labels in the neighborhood.

  2. Combined sabal and urtica extract compared with finasteride in men with benign prostatic hyperplasia: analysis of prostate volume and therapeutic outcome.

    Science.gov (United States)

    Sökeland, J

    2000-09-01

    To test the hypothesis that in patients with benign prostatic hyperplasia (BPH), the outcome of drug therapy with finasteride may be predictable from the baseline prostate volume and that positive clinical effects might be expected only in patients with prostate volumes of > 40 mL, using a subgroup analysis of results from a previously reported clinical trial of finasteride and phytotherapy. A subgroup of 431 patients was analysed from a randomized, multicentre, double-blind clinical trial involving 543 patients with the early stages of BPH. Patients received a fixed combination of extracts of saw palmetto fruit (Serenoa repens) and nettle root (Urtica dioica) (PRO 160/120) or the synthetic 5alpha-reductase inhibitor finasteride. The patients assessed had valid ultrasonographic measurements and baseline prostate volumes of either 40 mL. All 516 patients were included in the safety analysis. The results of the original trial showed equivalent efficacy for both treatments. The mean (SD) maximum urinary flow (the main outcome variable) increased (from baseline values) after 24 weeks by 1.9 (5.6) mL/s with PRO 160/120 and by 2.4 (6.3) mL/s with finasteride. There were no statistically significant group differences (P = 0.52). The subgroups with small prostates ( 40 mL were similar, at 2.3 (6.1) and 2. 2 (5.3) mL/s, respectively. There were improvements in the International Prostate Symptom Score in both treatment groups, with no statistically significant differences. The subgroup analysis showed slightly better results for voiding symptoms in the patients with prostates of > 40 mL, but there were also improvements in the subgroup with smaller prostates. The safety analysis showed that more patients in the finasteride group reported adverse events and also there were more adverse events in this group than in patients treated with PRO 160/120. The present analysis showed that the efficacy of both PRO 160/120 and finasteride was equivalent and unrelated to prostate volume

  3. Comprehensive low-dose imaging of carotid and coronary arteries with a single-injection dual-source CT angiography protocol.

    Science.gov (United States)

    Tognolini, A; Arellano, C S; Marfori, W; Heidari, G; Sayre, J W; Krishnam, M S; Ruehm, S G

    2014-03-01

    To assess the feasibility of a fast single-bolus combined carotid and coronary computed tomography angiography (CTA) protocol in asymptomatic patients. Thirty-three consecutive patients (18 women and 15 men) with a median age of 61 ± 14 years old (range 37-87 years) with known or suspected atherosclerotic disease were enrolled in this prospective study. A single breath-hold, single biphasic injection protocol (50 ml at 3 ml/s, 50 ml at 5 ml/s, 50 ml saline flush at 5 ml/s) was used for combined CTA imaging of the supra-aortic (SAA) and coronary arteries (CA) on a 64-slice dual-source CT (DSCT) machine. Helical CTA acquisition of the SAA was followed by prospective electrocardiography (ECG)-triggered coronary CTA. Subjective (four-point scale) image quality and objective signal-to-noise (SNR) and contrast-to-noise (CNR) measurements were performed. Vascular disease was graded on a four-point scale (grade 1: absent; grade 2: mild, grade 3: moderate; grade 4: severe). The radiation dose was recorded for each patient. The average enhancement and subjective quality score of SAA and CA segments were 396 HU/358 HU and 1.2 ± 0.3/1.72 ± 0.4, respectively. The SNR was 27.1 ± 1.7 in the SAA and 21.6 ± 1.6 in the CA (p grade 2 and 1/33 (3%) had grade 3 disease. CA findings were as follows: 25/33 (76%) showed no disease and 6/33 (18%) patients had grade 2 and 2/33 (6%) had grade 3 disease. Five patients had disease in both districts. The average radiation dose for the combined CTA angiogram was 4.3 ± 0.6 mSv. A fast, low-dose combined DSCT angiography protocol appears technically feasible for imaging carotid and coronary atherosclerotic disease. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning

    Energy Technology Data Exchange (ETDEWEB)

    Felmly, Lloyd M. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiothoracic Surgery, Department of Surgery, Charleston, SC (United States); De Cecco, Carlo N.; Varga-Szemes, Akos; McQuiston, Andrew D. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J.; Litwin, Sheldon E.; Bayer, Richard R. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany)

    2017-05-15

    To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. Besides a higher body-mass-index in group B (24.8±3.8 kg/m{sup 2} vs. 28.1±5.4 kg/m{sup 2}, P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. (orig.)

  5. Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning

    International Nuclear Information System (INIS)

    Felmly, Lloyd M.; De Cecco, Carlo N.; Varga-Szemes, Akos; McQuiston, Andrew D.; Schoepf, U.J.; Litwin, Sheldon E.; Bayer, Richard R.; Mangold, Stefanie; Vogl, Thomas J.; Wichmann, Julian L.

    2017-01-01

    To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. Besides a higher body-mass-index in group B (24.8±3.8 kg/m 2 vs. 28.1±5.4 kg/m 2 , P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. (orig.)

  6. Water vapour and methane coupling in the stratosphere observed using SCIAMACHY solar occultation measurements

    Directory of Open Access Journals (Sweden)

    S. Noël

    2018-04-01

    Full Text Available An improved stratospheric water vapour data set has been retrieved from SCIAMACHY/ENVISAT solar occultation measurements. It is similar to that successfully applied to methane and carbon dioxide. There is now a consistent set of data products for the three constituents covering the altitudes 17–45 km, the latitude range between about 50 and 70° N, and the period August 2002 to April 2012. The new water vapour concentration profiles agree with collocated results from ACE-FTS and MLS/Aura to within  ∼  5 %. A significant positive linear change in water vapour for the time 2003–2011 is observed at lower stratospheric altitudes with a value of about 0.015 ± 0.008 ppmv year−1 around 17 km. Between 30 and 37 km the changes become significantly negative (about −0.01 ± 0.008 ppmv year−1; all errors are 2σ values. The combined analysis of the SCIAMACHY methane and water vapour time series shows the expected anti-correlation between stratospheric methane and water vapour and a clear temporal variation related to the Quasi-Biennial Oscillation (QBO. Above about 20 km most of the additional water vapour is attributed to the oxidation of methane. In addition short-term fluctuations and longer-term variations on a timescale of 5–6 years are observed. The SCIAMACHY data confirm that at lower altitudes the amount of water vapour and methane are transported from the tropics to higher latitudes via the shallow branch of the Brewer–Dobson circulation.

  7. Urodynamic implications of benign prostatic hyperplasia

    DEFF Research Database (Denmark)

    Jensen, K M; Andersen, J T

    1990-01-01

    By the age of 60, about 70% of men have developed benign prostatic hyperplasia (BPH), and 85%-95% of these have symptomatic dysfunction of the lower urinary tract, 10%-20% undergoing prostatectomy. Although transurethral resection of the prostate is generally considered to be a safe and effective...... instability has no bearing on the postoperative result. Measurement of urinary flow, in contrast, is of predictive value in BPH, patients in whom the maximum urinary flow before surgery is more than 15 ml/s having significantly worse results of surgery than those with a maximum urinary flow of less than 15 ml...

  8. A Multilevel Secure Workflow Management System

    National Research Council Canada - National Science Library

    Kang, Myong H; Froscher, Judith N; Sheth, Amit P; Kochut, Krys J; Miller, John A

    1999-01-01

    The Department of Defense (DoD) needs multilevel secure (MLS) workflow management systems to enable globally distributed users and applications to cooperate across classification levels to achieve mission critical goals...

  9. Growth of carbon nanoflowers on glass slides using sparked iron as a catalyst

    International Nuclear Information System (INIS)

    Thongtem, Somchai; Singjai, Pisith; Thongtem, Titipun; Preyachoti, Suksawat

    2006-01-01

    Carbon nanotubes (CNTs) were grown on glass slides using iron as a catalyst. By using 6 kV voltage, iron wire with 0.5 mm in diameter was sparked for 1, 2, 10 and 100 times to form iron dots/islands on the slides. CNTs were subsequently grown in a gas mixture of 10 ml/s Ar and 0.1 ml/s C 2 H 2 at a temperature range of 700-900 K for 300 s (5 min). In scanning and transmission electron microscopies, the CNTs grown on iron dots appear like flowers composed of carbon with hexagonal structure. In addition, the effects of oxide and gold sputtering on the growth of CNTs were studied. Both have no major influence on the growth

  10. A Collocation Method by Moving Least Squares Applicable to European Option Pricing

    Directory of Open Access Journals (Sweden)

    M. Amirfakhrian

    2016-05-01

    Full Text Available The subject matter of the present inquiry is the pricing of European options in the actual form of numbers. To assess the numerical prices of European options, a scheme independent of any kind of mesh but rather powered by moving least squares (MLS estimation is made. In practical terms, first the discretion of time variable is implemented and then, an MLS-powered method is applied for spatial approximation. As, unlike other methods, these courses of action mentioned here don't rely on a mesh, one can firmly claim they are to be categorized under mesh-less methods. And, of course, at the end of the paper, various experiments are offered to prove how efficient and how powerful the introduced approach is.

  11. Report of a large depletion in the ozone layer over southern Brazil and Uruguay by using multi-instrumental data

    Science.gov (United States)

    Bresciani, Caroline; Dornelles Bittencourt, Gabriela; Valentin Bageston, José; Kirsch Pinheiro, Damaris; Schuch, Nelson Jorge; Bencherif, Hassan; Paes Leme, Neusa; Vaz Peres, Lucas

    2018-03-01

    Ozone is one of the chemical compounds that form part of the atmosphere. It plays a key role in the stratosphere where the ozone layer is located and absorbs large amounts of ultraviolet radiation. However, during austral spring (August-November), there is a massive destruction of the ozone layer, which is known as the Antarctic ozone hole. This phenomenon decreases ozone concentration in that region, which may affect other regions in addition to the polar one. This anomaly may also reach mid-latitudes; hence, it is called the secondary effect of the Antarctic ozone hole. Therefore, this study aims to identify the passage of an ozone secondary effect (OSE) event in the region of the city of Santa Maria - RS (29.68° S, 53.80° W) by means of a multi-instrumental analysis using the satellites TIMED/SABER, AURA/MLS, and OMI-ERS. Measurements were made in São Martinho da Serra/RS - Brazil (29.53° S, 53.85° W) using a sounding balloon and a Brewer Spectrophotometer. In addition, the present study aims to describe and analyse the influence that this stratospheric ozone reduction has on temperatures presented by these instruments, including data collected through the radio occultation technique. The event was first identified by the AURA/MLS satellite on 19 October 2016 over Uruguay. This reduction in ozone concentration was found by comparing the climatology for the years 1996-1998 for the state of Rio Grande do Sul, which is close to Uruguay. This event was already observed in Santa Maria/RS-Brazil on 20 October 2016 as presented by the OMI-ERS satellite and the Brewer Spectrophotometer. Moreover, a significant decrease was reported by the TIMED/SABER satellite in Uruguay. On 21 October, the poor ozone air mass was still over the region of interest, according to the OMI-ERS satellite, data from the sounding balloon launched in Santa Maria/RS-Brazil, and measurements made by the AURA/MLS satellite. Furthermore, the influence of ozone on the stratosphere temperature

  12. A linear CO chemistry parameterization in a chemistry-transport model: evaluation and application to data assimilation

    Directory of Open Access Journals (Sweden)

    M. Claeyman

    2010-07-01

    Full Text Available This paper presents an evaluation of a new linear parameterization valid for the troposphere and the stratosphere, based on a first order approximation of the carbon monoxide (CO continuity equation. This linear scheme (hereinafter noted LINCO has been implemented in the 3-D Chemical Transport Model (CTM MOCAGE (MOdèle de Chimie Atmospherique Grande Echelle. First, a one and a half years of LINCO simulation has been compared to output obtained from a detailed chemical scheme output. The mean differences between both schemes are about ±25 ppbv (part per billion by volume or 15% in the troposphere and ±10 ppbv or 100% in the stratosphere. Second, LINCO has been compared to diverse observations from satellite instruments covering the troposphere (Measurements Of Pollution In The Troposphere: MOPITT and the stratosphere (Microwave Limb Sounder: MLS and also from aircraft (Measurements of ozone and water vapour by Airbus in-service aircraft: MOZAIC programme mostly flying in the upper troposphere and lower stratosphere (UTLS. In the troposphere, the LINCO seasonal variations as well as the vertical and horizontal distributions are quite close to MOPITT CO observations. However, a bias of ~−40 ppbv is observed at 700 Pa between LINCO and MOPITT. In the stratosphere, MLS and LINCO present similar large-scale patterns, except over the poles where the CO concentration is underestimated by the model. In the UTLS, LINCO presents small biases less than 2% compared to independent MOZAIC profiles. Third, we assimilated MOPITT CO using a variational 3D-FGAT (First Guess at Appropriate Time method in conjunction with MOCAGE for a long run of one and a half years. The data assimilation greatly improves the vertical CO distribution in the troposphere from 700 to 350 hPa compared to independent MOZAIC profiles. At 146 hPa, the assimilated CO distribution is also improved compared to MLS observations by reducing the bias up to a factor of 2 in the tropics

  13. Thickness-dependent magneto-optical effects in hole-doped GaS and GaSe multilayers: a first-principles study

    Science.gov (United States)

    Li, Fei; Zhou, Xiaodong; Feng, Wanxiang; Fu, Botao; Yao, Yugui

    2018-04-01

    Recently, two-dimensional (2D) GaS and GaSe nanosheets were successfully fabricated and the measured electronic, mechanical, and optoelectronic properties are excellent. Here, using the first-principles density functional theory, we investigate the magnetic, optical, and magneto-optical (MO) Kerr and Faraday effects in hole-doped GaS and GaSe multilayers. GaS and GaSe monolayers (MLs) manifest ferromagnetic ground states by introducing even a small amount of hole doping, whereas the magnetism in GaS and GaSe multilayers are significantly different under hole doping. Our results show that ferromagnetic states can be easily established in GaS bilayers and trilayers under proper hole doping, however, most of GaSe multilayers are more favorable to nonmagnetic states. The magnetic moments in GaS multilayers are weakened remarkably with the increasing of thin film thickness and are negligible more than three MLs. This leads to the thickness dependence of MO Kerr and Faraday effects. Furthermore, the MO effects strongly depend on the doping concentration and therefore are electrically controllable by adjusting the number of holes via gate voltage. The substrate effects on the MO properties are also discussed. Combining the unique MO and other interesting physical properties make GaS and GaSe a superior 2D material platform for semiconductor MO and spintronic nanodevices.

  14. An Application of Alloy to Static Analysis for Secure Information Flow and Verification of Software Systems

    National Research Council Canada - National Science Library

    Shaffer, Alan B

    2008-01-01

    Within a multilevel secure (MLS) system, flaws in design and implementation can result in overt and covert channels, both of which may be exploited by malicious software to cause unauthorized information flows...

  15. A Proposal to Develop a Biotechnology Information Facility

    National Research Council Canada - National Science Library

    Spalding, John

    2002-01-01

    The objective of this grant was to develop facilities and information resources that support current research in biotechnology and to meet the goal of strengthening the biological science programs at HBCUs/Mls...

  16. An in vivo assessment of the influence of needle gauges on endodontic irrigation flow rate.

    Science.gov (United States)

    Gopikrishna, Velayutham; Sibi, Swamy; Archana, Durvasulu; Pradeep Kumar, Angabakkam Rajasekaran; Narayanan, Lakshmi

    2016-01-01

    The aim of this clinical study was to assess the influence of irrigation needle gauge on endodontic irrigation flow rates. In vivo assessment. Five specialist endodontists performed intracanal irrigation procedures on 50 mesiobuccal canal of mandibular first molars using three different irrigation needle gauges. Data of time taken for irrigation was recorded by an irrigation testing system and analyzed using independent sample "T" test and one-way analysis of variance (ANOVA) test. The level of significance was set at P < 0.05. The following tests were used for the statistical analysis: Independent sample "T" test, one-way ANOVA test, and post hoc multiple comparison was carried out using Tukey's honest significant difference (HSD) test using Statistical Package for the Social Sciences (SPSS) version 16 for Windows. The average flow rate of 26 gauge was 0.27 mLs(-1), of 27 gauge was 0.19 mLs(-1), and of 30 gauge was 0.09 mls(-1). There was statistical significance among the gauges (P < 0.001). 26 gauge had highest flow rate when compared with other groups followed by 27 gauge and 30 gauge respectively. The operator variability for flow rate of three endodontic irrigation needle gauges (26 gauge, 27 gauge, and 30 gauge) was found to be not significant. Needle gauge has significant influence on endodontic irrigation flow rate.

  17. Magnetite nano-islands on Graphene

    Science.gov (United States)

    Anderson, Nathaniel; Zhang, Qiang; Rosenberg, Richard; Vaknin, David

    X-ray magnetic circular dichroism (XMCD) of ex-situ iron nano-islands grown on graphene reveals that iron oxidation spontaneously leads to the formation of magnetite nano-particles - i.e, the formation of the inverse spinel Fe3O4. Fe islands have been grown with two different heights (20 and 75 MLs) on epitaxial graphene and we have determined their magnetic behavior both as function of temperature and applied external field. Our XAS and XMCD at an applied magnetic field of B = 5 T show that the thin film (20 MLs) is totally converted to magnetite whereas the thicker film (75 MLs) exhibits magnetite properties but also those of pure metal iron. For both samples, temperature dependence of the XMCD shows clear transitions at ~120 K consistent with the Verwey transition of bulk magnetite. XMCD at low temperatures shows a weak hysteresis and provide the average spin and angular-momentum moments, the dipolar term, and the total moment . In addition, manipulation and comparison of the XMCD data from both samples allows us to extract information about the pure iron nano-islands from the thicker sample. Ames Laboratory is supported by the U.S. DOE, BES, MSE Contract No. DE-AC02-07CH11358. APS is supported by U.S. DOE Contract No. DE-AC02-06CH11357.

  18. Brain activation to negative stimuli mediates a relationship between adolescent marijuana use and later emotional functioning.

    Science.gov (United States)

    Heitzeg, Mary M; Cope, Lora M; Martz, Meghan E; Hardee, Jillian E; Zucker, Robert A

    2015-12-01

    This work investigated the impact of heavy marijuana use during adolescence on emotional functioning, as well as the brain functional mediators of this effect. Participants (n=40) were recruited from the Michigan Longitudinal Study (MLS). Data on marijuana use were collected prospectively beginning in childhood as part of the MLS. Participants were classified as heavy marijuana users (n=20) or controls with minimal marijuana use. Two facets of emotional functioning-negative emotionality and resiliency (a self-regulatory mechanism)-were assessed as part of the MLS at three time points: mean age 13.4, mean age 19.6, and mean age 23.1. Functional neuroimaging data during an emotion-arousal word task were collected at mean age 20.2. Negative emotionality decreased and resiliency increased across the three time points in controls but not heavy marijuana users. Compared with controls, heavy marijuana users had less activation to negative words in temporal, prefrontal, and occipital cortices, insula, and amygdala. Activation of dorsolateral prefrontal cortex to negative words mediated an association between marijuana group and later negative emotionality. Activation of the cuneus/lingual gyrus mediated an association between marijuana group and later resiliency. Results support growing evidence that heavy marijuana use during adolescence affects later emotional outcomes. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Levels of arsenic, cadmium, lead and mercury in the branchial plate and muscle tissue of mobulid rays

    International Nuclear Information System (INIS)

    Ooi, Michelle S.M.; Townsend, Kathy A.; Bennett, Michael B.; Richardson, Anthony J.; Fernando, Daniel; Villa, Cesar A.; Gaus, Caroline

    2015-01-01

    Highlights: • Branchial plate and muscle tissue from mobulid rays were analysed for certain metals. • Mean concentrations of cadmium in Mobula japanica were above the EC ML. • Mean inorganic arsenic concentration in Mobula japanica muscle equalled the FSANZ ML. • Mean concentration of lead in Manta alfredi muscle tissue exceeded EC and Codex MLs. • There were significant correlations between the types of tissues for some metals. - Abstract: Mobulid rays are targeted in fisheries for their branchial plates, for use in Chinese medicine. Branchial plate and muscle tissue from Mobula japanica were collected from fish markets in Sri Lanka, and muscle tissue biopsies from Manta alfredi in Australia. These were analysed for arsenic, cadmium, lead and mercury and compared to maximum levels (MLs) set by Food Standards Australia and New Zealand (FSANZ), European Commission (EC) and Codex Alimentarius Commission. The estimated intake for a vulnerable human age group was compared to minimal risk levels set by the Agency for Toxic Substances and Disease Registry. The mean inorganic arsenic concentration in M. japanica muscle was equivalent to the FSANZ ML while cadmium exceeded the EC ML. The mean concentration of lead in M. alfredi muscle tissue exceeded EC and Codex MLs. There were significant positive linear correlations between branchial plate and muscle tissue concentrations for arsenic, cadmium and lead

  20. Counting Tm dopant atoms around GaN dots using high-angle annular dark field images

    International Nuclear Information System (INIS)

    Rouvière, J-L; Okuno, H; Jouneau, P H; Bayle-Guillemaud, P; Daudin, B

    2011-01-01

    High resolution Z-contrast STEM imaging is used to study the Tm doping of GaN quantum dots grown in AlN by molecular beam epitaxy (MBE). High-angle annular dark field (HAADF) imaging allows us to visualize directly individual Tm atoms in the AlN matrix and even to count the number of Tm atoms in a given AlN atomic column. A new visibility coefficient to determine quantitatively the number of Tm atoms in a given atomic column is introduced. It is based on locally integrated intensities rather than on peak intensities of HAADF images. STEM image simulations shows that this new visibility is less sensitive to the defocus-induced blurring or to the position of the Tm atom within the thin lamella. Most of the Tm atoms diffuse out of GaN dots. Tm atoms are found at different positions in the AlN matrix, (i) Above the wetting layer, Tm atoms are spread within a thickness of 14 AlN monolayers (MLs). (ii) Above the quantum dots all the Tm are located in the same plane situated at 2-3 MLs above the apex of the GaN dot, i.e. at a distance of 14 MLs from the wetting layer, (iii) In addition, Tm can diffuse very far from the GaN dot by following threading dislocations lines.

  1. Ozone mixing ratios inside tropical deep convective clouds from OMI satellite measurements

    Directory of Open Access Journals (Sweden)

    J. R. Ziemke

    2009-01-01

    Full Text Available We have developed a new technique for estimating ozone mixing ratio inside deep convective clouds. The technique uses the concept of an optical centroid cloud pressure that is indicative of the photon path inside clouds. Radiative transfer calculations based on realistic cloud vertical structure as provided by CloudSat radar data show that because deep convective clouds are optically thin near the top, photons can penetrate significantly inside the cloud. This photon penetration coupled with in-cloud scattering produces optical centroid pressures that are hundreds of hPa inside the cloud. We combine measured column ozone and the optical centroid cloud pressure derived using the effects of rotational-Raman scattering to estimate O3 mixing ratio in the upper regions of deep convective clouds. The data are obtained from the Ozone Monitoring Instrument (OMI onboard NASA's Aura satellite. Our results show that low O3 concentrations in these clouds are a common occurrence throughout much of the tropical Pacific. Ozonesonde measurements in the tropics following convective activity also show very low concentrations of O3 in the upper troposphere. These low amounts are attributed to vertical injection of ozone poor oceanic boundary layer air during convection into the upper troposphere followed by convective outflow. Over South America and Africa, O3 mixing ratios inside deep convective clouds often exceed 50 ppbv which are comparable to mean background (cloud-free amounts and are consistent with higher concentrations of injected boundary layer/lower tropospheric O3 relative to the remote Pacific. The Atlantic region in general also consists of higher amounts of O3 precursors due to both biomass burning and lightning. Assuming that O3 is well mixed (i.e., constant mixing ratio with height up to the tropopause, we can estimate the stratospheric column O3 over

  2. Feasibility of power contrast injections and bolus triggering during CT scans in oncologic patients with totally implantable venous access ports of the forearm

    International Nuclear Information System (INIS)

    Goltz, Jan Peter; Machann, Wolfram; Noack, Claudia; Hahn, Dietbert; Kickuth, Ralph

    2011-01-01

    Background: Conventional totally implantable venous access ports (TIVAPs) are not approved for power contrast injections but often remain the only venous access site in oncologic patients. Therefore, these devices can play an important role if patients with a TIVAP are scheduled for a contrast-enhanced computed tomography (ceCT) as vascular access may become more difficult during the course of chemotherapy. Purpose: To evaluate the feasibility and safety of power injections in conventional TIVAPs in the forearm and to analyze the feasibility of bolus triggering during CT scans. Material and Methods: In this retrospective study we analyzed 177 power injections in 141 patients with TIVAPs in the forearm. Between October 2008 and March 2010 all patients underwent power injections (1.5 mL/s, 150 psi) via the TIVAP for ceCT because conventional vascular access via a peripheral vein had failed. Adequate functioning and catheter's tip location after injection were evaluated. Peak injection pressure and attenuation levels of aorta, liver and spleen were analyzed and compared with results of 50 patients who were injected via classical peripheral cannulas (3 mL/s, 300 psi). Feasibility of automatic scan initiation was evaluated. In vitro the port was stressed with 5 mL/s (300 psi). Results: One TIVAP showed tip dislocation with catheter rupture. Three (2.1%) devices were explanted owing to assumed infection within 4 weeks after the injection. Mean injection pressure was 121.9 ±24.1 psi. Triggering with automatic scan initiation succeeded in 13/44 (29.6%) scans. Injection via classical cannulas resulted in significantly higher enhancement (p < 0.05). In vitro the port system tolerated flow rates of up to 5 mL/s, injection pressures of up to 338 psi. Conclusion: Power injection is a safe alternative for patients with TIVAPs in the forearm if classic vascular access ultimately fails. Triggering was successful in one-third of the attempts. Image quality in the arterial phase

  3. 31P NMR spectroscopy and HbO2 cryospectrophotometry in prediction of tumor radioresistance caused by hypoxia.

    Science.gov (United States)

    Rofstad, E K; DeMuth, P; Fenton, B M; Ceckler, T L; Sutherland, R M

    1989-04-01

    The aim of this study was to search for possible relationships between the fraction of radiobiologically hypoxic cells in tumors and their 31P NMR spectral parameters and intracapillary HbO2 saturations. Four different tumor lines, two murine sarcomas (KHT, RIF-1) and two human ovarian carcinoma xenografts (MLS, OWI), were used. When tumor volume increased from about 200 mm3 to about 2000 mm3, hypoxic fraction increased from 12 to 23% for the KHT line, from 0.9 to 1.7% for the RIF-1 line, and from 9 to 28% for the MLS line. The OWI line showed similar hypoxic fractions at 200 (17%) and 2000 mm3 (15%). Tumor bioenergetic status decreased, that is, the inorganic phosphate (Pi) resonance increased and the phosphocreatine (PCr) and nucleoside triphosphate beta (NTP beta) resonances decreased, with increasing tumor volume for the KHT, RIF-1, and MLS lines, whereas the OWI line did not show any changes in the 31P NMR spectral parameters during tumor growth. Similarly, tumor HbO2 saturation status, that is, the fraction of vessels with HbO2 saturation above 30%, decreased with increasing tumor volume for the KHT, RIF-1, and MLS lines, but remained unchanged during tumor growth for the OWI line. Although the data indicated a relationship between hypoxic fraction and tumor bioenergetic status as well as tumor HbO2 saturation status within a specific line during tumor growth, there was no correlation between hypoxic fraction and tumor bioenergetic status or tumor HbO2 saturation status across the four tumor lines. This may have occurred because cell survival time under hypoxic stress as well as fraction of non-clonogenic, but metabolically active hypoxic cells differed among the tumor lines. This indicates that 31P NMR spectroscopy and HbO2 cryospectrophotometry data have to be supplemented with other data to be useful in prediction of tumor radioresistance caused by hypoxia.

  4. Practice patterns for the use of iodinated i.v. contrast media for pediatric CT studies: a survey of the Society for Pediatric Radiology.

    Science.gov (United States)

    Callahan, Michael J; Servaes, Sabah; Lee, Edward Y; Towbin, Alexander J; Westra, Sjirk J; Frush, Donald P

    2014-04-01

    There are limited data available on the use of i.v. contrast media for CT studies in the pediatric population. The purpose of this study is to determine the practice patterns of i.v. contrast media usage for pediatric CT by members of the Society for Pediatric Radiology (SPR). SPR members were surveyed regarding the use of i.v. contrast media for pediatric CT studies. Questions pertained to information required before administering i.v. contrast media, types of central catheters for injecting i.v. contrast media, injection rates based on angiocatheter size and study type, and management of i.v. contrast media extravasation. The response rate of 6% (88/1545) represented practice patterns of 26% (401/1545) of the SPR membership. Most respondents thought the following clinical information was mandatory before i.v. contrast media administration: allergy to i.v. contrast media (97%), renal insufficiency (97%), current metformin use (72%), significant allergies (61%), diabetes (54%), and asthma (52%). Most administered i.v. contrast media through nonimplanted central venous catheters (78%), implanted venous ports (78%), and peripherally inserted central catheters (72%). The most common maximum i.v. contrast media injection rates were 5.0 mL/s or greater for a 16-gauge angiocatheter, 4.0 mL/s for an 18-gauge angiocatheter, 3.0 mL/s for a 20-gauge angiocatheter, and 2.0 mL/s for a 22-gauge angiocatheter. For soft-tissue extravasation of i.v. contrast media, 95% elevate the affected extremity, 76% use ice, and 45% use heat. The results of this survey illustrate the collective opinion of a subset of SPR members relating to the use of i.v. contrast media in pediatric CT, providing guidelines for clinical histories needed before i.v. contrast media, maximum i.v. contrast injection rates for standard angiocatheters, contrast media injection rates for specific CT studies, and management of i.v. contrast media soft-tissue extravasation.

  5. In Situ Bioreduction of Uranium (VI) to Submicromolar Levels and Reoxidation by Dissolved Oxygen

    International Nuclear Information System (INIS)

    Wu, Weimin; Carley, Jack M.; Luo, Jian; Ginder-Vogel, Matthew A.; Cardenas, Erick; Leigh, Mary Beth; Hwang, Chaichi; Kelly, Shelly D.; Ruan, Chuanmin; Wu, Liyou; Van Nostrand, Joy; Gentry, Terry J.; Lowe, Kenneth Alan; Mehlhorn, Tonia L.; Carroll, Sue L.; Luo, Wensui; Fields, Matthew Wayne; Gu, Baohua; Watson, David B.; Kemner, Kenneth M.; Marsh, Terence; Tiedje, James; Zhou, Jizhong; Fendorf, Scott; Kitanidis, Peter K.; Jardine, Philip M.; Criddle, Craig

    2007-01-01

    Groundwater within Area 3 of the U.S. Department of Energy (DOE) Environmental Remediation Sciences Program (ERSP) Field Research Center at Oak Ridge, TN (ORFRC) contains up to 135 (micro)M uranium as U(VI). Through a series of experiments at a pilot scale test facility, we explored the lower limits of groundwater U(VI) that can be achieved by in-situ biostimulation and the effects of dissolved oxygen on immobilized uranium. Weekly 2 day additions of ethanol over a 2-year period stimulated growth of denitrifying, Fe(III)-reducing, and sulfate-reducing bacteria, and immobilization of uranium as U(IV), with dissolved uranium concentrations decreasing to low levels. Following sulfite addition to remove dissolved oxygen, aqueous U(VI) concentrations fell below the U.S. Environmental Protection Agency maximum contaminant limit (MCL) for drinking water ( -1 or 0.126 (micro)M). Under anaerobic conditions, these low concentrations were stable, even in the absence of added ethanol. However, when sulfite additions stopped, and dissolved oxygen (4.0-5.5 mg L -1 ) entered the injection well, spatially variable changes in aqueous U(VI) occurred over a 60 day period, with concentrations increasing rapidly from <0.13 to 2.0 (micro)M at a multilevel sampling (MLS) well located close to the injection well, but changing little at an MLS well located further away. Resumption of ethanol addition restored reduction of Fe(III), sulfate, and U(VI) within 36 h. After 2 years of ethanol addition, X-ray absorption near-edge structure spectroscopy (XANES) analyses indicated that U(IV) comprised 60-80% of the total uranium in sediment samples. At the completion of the project (day 1260), U concentrations in MLS wells were less than 0.1 (micro)M. The microbial community at MLS wells with low U(VI) contained bacteria that are known to reduce uranium, including Desulfovibrio spp. and Geobacter spp., in both sediment and groundwater. The dominant Fe(III)-reducing species were Geothrix spp

  6. Development of an in vitro bioassay for measuring susceptibility to macrocyclic lactone anthelmintics in Dirofilaria immitis.

    Science.gov (United States)

    Evans, Christopher C; Moorhead, Andrew R; Storey, Bobby E; Wolstenholme, Adrian J; Kaplan, Ray M

    2013-12-01

    For more than 20 years, anthelmintics of the macrocyclic lactone (ML) drug class have been widely and effectively used as preventives against the canine heartworm, Dirofilaria immitis. However, in recent years an increased number of lack of efficacy (LOE) cases are being reported, in which dogs develop mature heartworm infections despite receiving monthly prophylactic doses of ML drugs. While this situation is raising concerns that heartworms may be developing resistance to MLs, compelling evidence for this is still lacking. Resolution of this dilemma requires validated biological or molecular diagnostic assays, but, unfortunately, no such tests currently exist. To address this need, we developed and optimized a larval migration inhibition assay (LMIA) for use with D. immitis third-stage larvae. The LMIA was used to measure the in vitro dose-response of two ML drugs (ivermectin and eprinomectin) on a known ML-susceptible laboratory strain of D. immitis. A nonlinear regression model was fit to the dose-response data, from which IC50 values were calculated; the mean IC50 and 95% confidence interval for IVM was 4.56 μM (1.26-16.4 μM), greater than that for EPR at 2.02 μM (1.68-2.42 μM), and this difference was significant (p = 0.0428). The R (2) value for EPR assays (0.90) was also greater than that for IVM treatment (0.71). The consistency and reproducibility of the dose-response data obtained with this assay suggests that it may be a useful technique for investigating the relative susceptibilities to ML drugs in other D. immitis populations.

  7. Validation of MIPAS IMK/IAA temperature, water vapor, and ozone profiles with MOHAVE-2009 campaign measurements

    Directory of Open Access Journals (Sweden)

    G. P. Stiller

    2012-02-01

    Full Text Available MIPAS observations of temperature, water vapor, and ozone in October 2009 as derived with the scientific level-2 processor run by Karlsruhe Institute of Technology (KIT, Institute for Meteorology and Climate Research (IMK and CSIC, Instituto de Astrofísica de Andalucía (IAA and retrieved from version 4.67 level-1b data have been compared to co-located field campaign observations obtained during the MOHAVE-2009 campaign at the Table Mountain Facility near Pasadena, California in October 2009. The MIPAS measurements were validated regarding any potential biases of the profiles, and with respect to their precision estimates. The MOHAVE-2009 measurement campaign provided measurements of atmospheric profiles of temperature, water vapor/relative humidity, and ozone from the ground to the mesosphere by a suite of instruments including radiosondes, ozonesondes, frost point hygrometers, lidars, microwave radiometers and Fourier transform infra-red (FTIR spectrometers. For MIPAS temperatures (version V4O_T_204, no significant bias was detected in the middle stratosphere; between 22 km and the tropopause MIPAS temperatures were found to be biased low by up to 2 K, while below the tropopause, they were found to be too high by the same amount. These findings confirm earlier comparisons of MIPAS temperatures to ECMWF data which revealed similar differences. Above 12 km up to 45 km, MIPAS water vapor (version V4O_H2O_203 is well within 10% of the data of all correlative instruments. The well-known dry bias of MIPAS water vapor above 50 km due to neglect of non-LTE effects in the current retrievals has been confirmed. Some instruments indicate that MIPAS water vapor might be biased high by 20 to 40% around 10 km (or 5 km below the tropopause, but a consistent picture from all comparisons could not be derived. MIPAS ozone (version V4O_O3_202 has a high bias of up to +0.9 ppmv around 37 km which is due to a non-identified continuum like radiance contribution

  8. Validation of MIPAS IMK-IAA Temperature, Water Vapor, and Ozone Profiles with MOHAVE-2009 Campaign Measurements

    Science.gov (United States)

    Stiller, Gabrielle; Kiefer, M.; Eckert, E.; von Clarmann, T.; Kellmann, S.; Garcia-Comas, M.; Funke, B.; Leblanc, T.; Fetzer, E.; Froidevaux, L.; hide

    2012-01-01

    MIPAS observations of temperature, water vapor, and ozone in October 2009 as derived with the scientific level-2 processor run by Karlsruhe Institute of Technology (KIT), Institute for Meteorology and Climate Research (IMK) and CSIC, Instituto de Astrofisica de Andalucia (IAA) and retrieved from version 4.67 level-1b data have been compared to co-located field campaign observations obtained during the MOHAVE-2009 campaign at the Table Mountain Facility near Pasadena, California in October 2009. The MIPAS measurements were validated regarding any potential biases of the profiles, and with respect to their precision estimates. The MOHAVE-2009 measurement campaign provided measurements of atmospheric profiles of temperature, water vapor/relative humidity, and ozone from the ground to the mesosphere by a suite of instruments including radiosondes, ozonesondes, frost point hygrometers, lidars, microwave radiometers and Fourier transform infrared (FTIR) spectrometers. For MIPAS temperatures (version V4O_T_204), no significant bias was detected in the middle stratosphere; between 22 km and the tropopause MIPAS temperatures were found to be biased low by up to 2 K, while below the tropopause, they were found to be too high by the same amount. These findings confirm earlier comparisons of MIPAS temperatures to ECMWF data which revealed similar differences. Above 12 km up to 45 km, MIPAS water vapor (version V4O_H2O_203) is well within 10% of the data of all correlative instruments. The well-known dry bias of MIPAS water vapor above 50 km due to neglect of non-LTE effects in the current retrievals has been confirmed. Some instruments indicate that MIPAS water vapor might be biased high by 20 to 40% around 10 km (or 5 km below the tropopause), but a consistent picture from all comparisons could not be derived. MIPAS ozone (version V4O_O3_202) has a high bias of up to +0.9 ppmv around 37 km which is due to a non-identified continuum like radiance contribution. No further

  9. Validation of ACE-FTS v2.2 measurements of HCl, HF, CCl3F and CCl2F2 using space-, balloon- and ground-based instrument observations

    Directory of Open Access Journals (Sweden)

    C. Servais

    2008-10-01

    Full Text Available Hydrogen chloride (HCl and hydrogen fluoride (HF are respectively the main chlorine and fluorine reservoirs in the Earth's stratosphere. Their buildup resulted from the intensive use of man-made halogenated source gases, in particular CFC-11 (CCl3F and CFC-12 (CCl2F2, during the second half of the 20th century. It is important to continue monitoring the evolution of these source gases and reservoirs, in support of the Montreal Protocol and also indirectly of the Kyoto Protocol. The Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS is a space-based instrument that has been performing regular solar occultation measurements of over 30 atmospheric gases since early 2004. In this validation paper, the HCl, HF, CFC-11 and CFC-12 version 2.2 profile data products retrieved from ACE-FTS measurements are evaluated. Volume mixing ratio profiles have been compared to observations made from space by MLS and HALOE, and from stratospheric balloons by SPIRALE, FIRS-2 and Mark-IV. Partial columns derived from the ACE-FTS data were also compared to column measurements from ground-based Fourier transform instruments operated at 12 sites. ACE-FTS data recorded from March 2004 to August 2007 have been used for the comparisons. These data are representative of a variety of atmospheric and chemical situations, with sounded air masses extending from the winter vortex to summer sub-tropical conditions. Typically, the ACE-FTS products are available in the 10–50 km altitude range for HCl and HF, and in the 7–20 and 7–25 km ranges for CFC-11 and -12, respectively. For both reservoirs, comparison results indicate an agreement generally better than 5–10% above 20 km altitude, when accounting for the known offset affecting HALOE measurements of HCl and HF. Larger positive differences are however found for comparisons with single profiles from FIRS-2 and SPIRALE. For CFCs, the few coincident measurements available suggest that the differences

  10. Briefing paper : toward a best practice model for managed lanes in Texas.

    Science.gov (United States)

    2013-09-01

    Over the past two decades, agencies : have increasingly implemented managed : lanes (MLs) to mitigate growing urban traffic : congestion in the United States. Multiple operating : projects : representing a combination : of HOV-to-HOT conversions a...

  11. Sensor-Topology Based Simplicial Complex Reconstruction from Mobile Laser Scanning

    Science.gov (United States)

    Guinard, S.; Vallet, B.

    2018-05-01

    We propose a new method for the reconstruction of simplicial complexes (combining points, edges and triangles) from 3D point clouds from Mobile Laser Scanning (MLS). Our main goal is to produce a reconstruction of a scene that is adapted to the local geometry of objects. Our method uses the inherent topology of the MLS sensor to define a spatial adjacency relationship between points. We then investigate each possible connexion between adjacent points and filter them by searching collinear structures in the scene, or structures perpendicular to the laser beams. Next, we create triangles for each triplet of self-connected edges. Last, we improve this method with a regularization based on the co-planarity of triangles and collinearity of remaining edges. We compare our results to a naive simplicial complexes reconstruction based on edge length.

  12. Applying Bourdieu’s Field Theory to MLS Curricula Development

    DEFF Research Database (Denmark)

    Wien, Charlotte; Dorch, Bertil F.

    the tasks in the library. The hypothesis is that the subject specialist previously found him or herself in the upper part of the compass, while the librarians would be placed in the lower part. Obviously, this created a field of tension between the subject specialists and the librarians. A useful tool...... for the power to decide exactly what is associated with power and what is not persist. With the upgrading of LIS the librarians have moved upwards on the vertical axis and thereby challenge the subject specialist’s position. At the same time developments within the academic world have brought about...

  13. Geochemistry and hydrology of perched groundwater springs: assessing elevated uranium concentrations at Pigeon Spring relative to nearby Pigeon Mine, Arizona (USA)

    Science.gov (United States)

    Beisner, Kimberly R.; Paretti, Nicholas; Tillman, Fred; Naftz, David L.; Bills, Donald; Walton-Day, Katie; Gallegos, Tanya J.

    2017-01-01

    The processes that affect water chemistry as the water flows from recharge areas through breccia-pipe uranium deposits in the Grand Canyon region of the southwestern United States are not well understood. Pigeon Spring had elevated uranium in 1982 (44 μg/L), compared to other perched springs (2.7–18 μg/L), prior to mining operations at the nearby Pigeon Mine. Perched groundwater springs in an area around the Pigeon Mine were sampled between 2009 and 2015 and compared with material from the Pigeon Mine to better understand the geochemistry and hydrology of the area. Two general groups of perched groundwater springs were identified from this study; one group is characterized by calcium sulfate type water, low uranium activity ratio 234U/238U (UAR) values, and a mixture of water with some component of modern water, and the other group by calcium-magnesium sulfate type water, higher UAR values, and radiocarbon ages indicating recharge on the order of several thousand years ago. Multivariate statistical principal components analysis of Pigeon Mine and spring samples indicate Cu, Pb, As, Mn, and Cd concentrations distinguished mining-related leachates from perched groundwater springs. The groundwater potentiometric surface indicates that perched groundwater at Pigeon Mine would likely flow toward the northwest away from Pigeon Spring. The geochemical analysis of the water, sediment and rock samples collected from the Snake Gulch area indicate that the elevated uranium at Pigeon Spring is likely related to a natural source of uranium upgradient from the spring and not likely related to the Pigeon Mine.

  14. NLM MedlinePlus Magazine Team | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... Home Current issue contents Magazine Team Follow us Magazine Team National Library of Medicine at the National ... MLS, MA TREASURER Dennis Cryer, MD NIH MedlinePlus magazine is published by Friends of the NLM in ...

  15. Evolution of stratospheric ozone and water vapour time series studied with satellite measurements

    Directory of Open Access Journals (Sweden)

    A. Jones

    2009-08-01

    Full Text Available The long term evolution of stratospheric ozone and water vapour has been investigated by extending satellite time series to April 2008. For ozone, we examine monthly average ozone values from various satellite data sets for nine latitude and altitude bins covering 60° S to 60° N and 20–45 km and covering the time period of 1979–2008. Data are from the Stratospheric Aerosol and Gas Experiment (SAGE I+II, the HALogen Occultation Experiment (HALOE, the Solar BackscatterUltraViolet-2 (SBUV/2 instrument, the Sub-Millimetre Radiometer (SMR, the Optical Spectrograph InfraRed Imager System (OSIRIS, and the SCanning Imaging Absorption spectroMeter for Atmospheric CHartograpY (SCIAMACHY. Monthly ozone anomalies are calculated by utilising a linear regression model, which also models the solar, quasi-biennial oscillation (QBO, and seasonal cycle contributions. Individual instrument ozone anomalies are combined producing an all instrument average. Assuming a turning point of 1997 and that the all instrument average is represented by good instrumental long term stability, the largest statistically significant ozone declines (at two sigma from 1979–1997 are seen at the mid-latitudes between 35 and 45 km, namely −7.2%±0.9%/decade in the Northern Hemisphere and −7.1%±0.9%/in the Southern Hemisphere. Furthermore, for the period 1997 to 2008 we find that the same locations show the largest ozone recovery (+1.4% and +0.8%/decade respectively compared to other global regions, although the estimated trend model errors indicate that the trend estimates are not significantly different from a zero trend at the 2 sigma level. An all instrument average is also constructed from water vapour anomalies during 1991–2008, using the SAGE II, HALOE, SMR, and the Microwave Limb Sounder (Aura/MLS measurements. We report that the decrease in water vapour values after 2001 slows down around 2004–2005 in the lower tropical stratosphere (20–25 km and has even

  16. Lifetime and production rate of beauty baryons from Z decays

    CERN Document Server

    Abreu, P; Adye, T; Agasi, E; Ajinenko, I; Aleksan, Roy; Alekseev, G D; Allport, P P; Almehed, S; Alvsvaag, S J; Amaldi, Ugo; Amato, S; Andreazza, A; Andrieux, M L; Antilogus, P; Apel, W D; Arnoud, Y; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Bambade, P; Barão, F; Barate, R; Barbiellini, Guido; Bardin, Dimitri Yuri; Barker, G J; Baroncelli, A; Bärring, O; Barrio, J A; Bartl, Walter; Bates, M J; Battaglia, Marco; Baubillier, M; Baudot, J; Becks, K H; Begalli, M; Beillière, P; Belokopytov, Yu A; Benvenuti, Alberto C; Berggren, M; Bertrand, D; Bianchi, F; Bigi, M; Bilenky, S M; Billoir, P; Bloch, D; Blume, M; Blyth, S; Bocci, V; Bolognese, T; Bonesini, M; Bonivento, W; Booth, P S L; Borisov, G; Bosio, C; Bosworth, S; Botner, O; Bouquet, B; Bourdarios, C; Bowcock, T J V; Bozzo, M; Branchini, P; Brand, K D; Brenner, R A; Bricman, C; Brillault, L; Brown, R C A; Brückman, P; Brunet, J M; Bugge, L; Buran, T; Buys, A; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Cankocak, K; Cao, F; Carena, F; Carrilho, P; Carroll, L; Caso, Carlo; Castillo-Gimenez, M V; Cattai, A; Cavallo, F R; Cerrito, L; Chabaud, V; Chapkin, M M; Charpentier, P; Chaussard, L; Chauveau, J; Checchia, P; Chelkov, G A; Chierici, R; Chliapnikov, P V; Chochula, P; Chorowicz, V; Cindro, V; Collins, P; Contreras, J L; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Crawley, H B; Crennell, D J; Crosetti, G; Cuevas-Maestro, J; Czellar, S; Dahl-Jensen, Erik; Dahm, J; D'Almagne, B; Dam, M; Damgaard, G; Daum, A; Dauncey, P D; Davenport, Martyn; Da Silva, W; Defoix, C; Della Ricca, G; Delpierre, P A; Demaria, N; De Angelis, A; De Boeck, H; de Boer, Wim; De Brabandere, S; De Clercq, C; La Vaissière, C de; De Lotto, B; De Min, A; De Paula, L S; De Saint-Jean, C; Dijkstra, H; Di Ciaccio, Lucia; Djama, F; Dolbeau, J; Dönszelmann, M; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Dufour, Y; Dupont, F; Edsall, D M; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, Gösta; Elsing, M; Engel, J P; Ershaidat, N; Erzen, B; Espirito-Santo, M C; Falk, E; Fassouliotis, D; Feindt, Michael; Fenyuk, A; Ferrer, A; Filippas-Tassos, A; Firestone, A; Föth, H; Fokitis, E; Fontanelli, F; Formenti, F; Franek, B J; Frenkiel, P; Fries, D E C; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fürstenau, H; Fuster, J A; Galloni, A; Gamba, D; Gandelman, M; García, C; García, J; Gaspar, C; Gasparini, U; Gavillet, P; Gazis, E N; Gelé, D; Gerber, J P; Gibbs, M; Gillespie, D; Gokieli, R; Golob, B; Gopal, Gian P; Gorn, L; Górski, M; Gracco, Valerio; Graziani, E; Grosdidier, G; Gunnarsson, P; Günther, M; Guy, J; Haedinger, U; Hahn, F; Hahn, M; Hahn, S; Hajduk, Z; Hallgren, A; Hamacher, K; Hao, W; Harris, F J; Hedberg, V; Henriques, R P; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Higón, E; Hilke, Hans Jürgen; Hill, T S; Holmgren, S O; Holt, P J; Holthuizen, D J; Houlden, M A; Hrubec, Josef; Huet, K; Hultqvist, K; Ioannou, P; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, G; Jarry, P; Jean-Marie, B; Johansson, E K; Jönsson, L B; Jönsson, P E; Joram, Christian; Juillot, P; Kaiser, M; Kalmus, George Ernest; Kapusta, F; Karlsson, M; Karvelas, E; Katsanevas, S; Katsoufis, E C; Keränen, R; Khomenko, B A; Khovanskii, N N; King, B J; Kjaer, N J; Klein, H; Klovning, A; Kluit, P M; Köhne, J H; Köne, B; Kokkinias, P; Koratzinos, M; Kostyukhin, V; Kourkoumelis, C; Kuznetsov, O; Kramer, P H; Krammer, Manfred; Kreuter, C; Królikowski, J; Kronkvist, I J; Krumshtein, Z; Krupinski, W; Kubinec, P; Kucewicz, W; Kurvinen, K L; Lacasta, C; Laktineh, I; Lamblot, S; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Lapin, V; Last, I; Laugier, J P; Lauhakangas, R; Leder, Gerhard; Ledroit, F; Lefébure, V; Legan, C K; Leitner, R; Lemoigne, Y; Lemonne, J; Lenzen, Georg; Lepeltier, V; Lesiak, T; Liko, D; Lindner, R; Lipniacka, A; Lippi, I; Lörstad, B; Lokajícek, M; Loken, J G; López, J M; López-Fernandez, A; López-Aguera, M A; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J N; Maehlum, G; Maio, A; Malychev, V; Mandl, F; Marco, J; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Maron, T; Martínez-Rivero, C; Martínez-Vidal, F; Martí i García, S; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, M; McCubbin, M L; McKay, M; McNulty, M; Medbo, J; Meroni, C; Meyer, W T; Michelotto, M; Migliore, E; Mirabito, L; Mitaroff, Winfried A; Mjörnmark, U; Moa, T; Møller, R; Mönig, K; Monge, M R; Morettini, P; Müller, H; Mundim, L M; Murray, W J; Muryn, B; Myatt, Gerald; Naraghi, F; Navarria, Francesco Luigi; Navas, S; Negri, P; Némécek, S; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Nikolaenko, V; Niss, P; Nomerotski, A; Normand, Ainsley; Oberschulte-Beckmann, W; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, Risto; Ostankov, A P; Österberg, K; Ouraou, A; Paganini, P; Paganoni, M; Pagès, P; Palka, H; Papadopoulou, T D; Pape, L; Parkes, C; Parodi, F; Passeri, A; Pegoraro, M; Peralta, L; Pernegger, H; Pernicka, Manfred; Perrotta, A; Petridou, C; Petrolini, A; Phillips, H T; Piana, G; Pierre, F; Plaszczynski, S; Podobrin, O; Pol, M E; Polok, G; Poropat, P; Pozdnyakov, V; Prest, M; Privitera, P; Pukhaeva, N; Pullia, Antonio; Radojicic, D; Ragazzi, S; Rahmani, H; Rames, J; Ratoff, P N; Read, A L; Reale, M; Rebecchi, P; Redaelli, N G; Reid, D; Renton, P B; Resvanis, L K; Richard, F; Richardson, J; Rídky, J; Rinaudo, G; Ripp, I; Romero, A; Roncagliolo, I; Ronchese, P; Roos, L; Rosenberg, E I; Rosso, E; Roudeau, Patrick; Rovelli, T; Rückstuhl, W; Ruhlmann-Kleider, V; Ruiz, A; Rybicki, K; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sajot, G; Salt, J; Sánchez, J; Sannino, M; Schneider, H; Schyns, M A E; Sciolla, G; Scuri, F; Sedykh, Yu; Segar, A M; Seitz, A; Sekulin, R L; Shellard, R C; Siccama, I; Siegrist, P; Simonetti, S; Simonetto, F; Sissakian, A N; Sitár, B; Skaali, T B; Smadja, G; Smirnov, N; Smirnova, O G; Smith, G R; Sosnowski, R; Souza-Santos, D; Spassoff, Tz; Spiriti, E; Squarcia, S; Stäck, H; Stanescu, C; Stapnes, Steinar; Stavitski, I; Stepaniak, K; Stichelbaut, F; Stocchi, A; Strauss, J; Strub, R; Stugu, B; Szczekowski, M; Szeptycka, M; Tabarelli de Fatis, T; Tavernet, J P; Chikilev, O G; Tilquin, A; Timmermans, J; Tkatchev, L G; Todorov, T; Toet, D Z; Tomaradze, A G; Tomé, B; Torassa, E; Tortora, L; Tranströmer, G; Treille, D; Trischuk, W; Tristram, G; Trombini, A; Troncon, C; Tsirou, A L; Turluer, M L; Tyapkin, I A; Tyndel, M; Tzamarias, S; Überschär, B; Überschär, S; Ullaland, O; Uvarov, V; Valenti, G; Vallazza, E; van Apeldoorn, G W; van Dam, P; Van Doninck, W K; Van Eldik, J; Vassilopoulos, N; Vegni, G; Ventura, L; Venus, W A; Verbeure, F; Verlato, M; Vertogradov, L S; Vilanova, D; Vincent, P; Vitale, L; Vlasov, E; Vodopyanov, A S; Vrba, V; Wahlen, H; Walck, C; Wehr, A; Weierstall, M; Weilhammer, Peter; Wetherell, Alan M; Wicke, D; Wickens, J H; Wielers, M; Wilkinson, G R; Williams, W S C; Winter, M; Witek, M; Wormser, G; Woschnagg, K; Yip, K; Zach, F; Zacharatou-Jarlskog, C; Zaitsev, A; Zalewska-Bak, A; Zalewski, Piotr; Zavrtanik, D; Zevgolatakos, E; Zimin, N I; Zito, M; Zontar, D; Zuberi, R; Zucchelli, G C; Zumerle, G

    1995-01-01

    The production and decay of beauty baryons (b-baryons) have been studied using 1.7 \\times 10^6 Z hadronic decays collected by the DELPHI detector at LEP. Three different techniques were used to identify the b-baryons. The first method used pairs of a \\Lambda and a lepton to tag the b-baryon decay. The second method associated fully reconstructed \\Lambda_c baryons with leptons. The third analysis reconstructed the b-baryon decay points by forming secondary vertices from identified protons and muons of opposite sign. Using these methods the following production rates were measured: \\begin{eqnarray*} f(\\qb \\ra \\Bb) \\times \\BR(\\Bb \\ra \\mLs \\ell\\bar{\

  17. ARIS-Campaign: intercomparison of three ground based 22 GHz radiometers for middle atmospheric water vapor at the Zugspitze in winter 2009

    Directory of Open Access Journals (Sweden)

    C. Straub

    2011-09-01

    Full Text Available This paper presents the Alpine Radiometer Intercomparison at the Schneefernerhaus (ARIS, which took place in winter 2009 at the high altitude station at the Zugspitze, Germany (47.42° N, 10.98° E, 2650 m. This campaign was the first direct intercomparison between three new ground based 22 GHz water vapor radiometers for middle atmospheric profiling with the following instruments participating: MIRA 5 (Karlsruhe Institute of Technology, cWASPAM3 (Max Planck Institute for Solar System Research, Katlenburg-Lindau and MIAWARA-C (Institute of Applied Physics, University of Bern. Even though the three radiometers all measure middle atmospheric water vapor using the same rotational transition line and similar fundamental set-ups, there are major differences between the front ends, the back ends, the calibration concepts and the profile retrieval. The spectrum comparison shows that all three radiometers measure spectra without severe baseline artifacts and that the measurements are in good general agreement. The measurement noise shows good agreement to the values theoretically expected from the radiometer noise formula. At the same time the comparison of the noise levels shows that there is room for instrumental and calibration improvement, emphasizing the importance of low elevation angles for the observation, a low receiver noise temperature and an efficient calibration scheme.

    The comparisons of the retrieved profiles show that the agreement between the profiles of MIAWARA-C and cWASPAM3 with the ones of MLS is better than 0.3 ppmv (6% at all altitudes. MIRA 5 has a dry bias of approximately 0.5 ppm (8% below 0.1 hPa with respect to all other instruments. The profiles of cWASPAM3 and MIAWARA-C could not be directly compared because the vertical region of overlap was too small. The comparison of the time series at different altitude levels show a similar evolution of the H2O volume mixing ratio (VMR for the ground based

  18. Blood cell labeling with technetium-99m. II. Measurement of circulating blood volume by sup(99m)Tc-labeled red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T; Yoshida, H; Matsuda, S; Kimura, H; Miura, N [Fukushima Medical Coll. (Japan)

    1978-02-01

    Using a labeling method with sup(99m)Tc-pertechnetate to red blood cells (RBC), circulating blood volume was measured in comparison with that from /sup 51/Cr-labeled RBC method. The technique is easier than already published methods, because CIS kit for sup(99m)Tc-RBC labeling (TCK-11) became to be available recently. Two mls of ACD-anticoagulated blood were withdrawn and 0.5 ml of reducing reagent prepared just before use was added to blood, waiting 5 minutes and discarding the serum after centrifugation, then adding 100 ..mu..Ci of sup(99m)Tc. After washing the labeled cells by isotonic saline, cells were re-suspended in 10 ml of saline and injected to the subject. Blood specimen was obtained 10, 30, 60 and 120 minutes after infusion and blood volume was calculated by the usual way. Circulating blood volume by sup(99m)Tc was well correlated with that by /sup 51/Cr (=0.98, p 0.01), however, the value calculated from sup(99m)Tc were 4.8 percent higher than those by /sup 51/Cr, which suggested the elution of sup(99m)Tc from labeled RBC. sup(99m)Tc method has the advantages that higher radioactivity can be obtained in small amount of blood, which is useful in the determination of blood volume in children or in small animals in the laboratory. The measurement of blood volume of the mouse was done by using sup(99m)Tc method. The results were 1.70 +- 0.06 ml (6.35 +- 0.18%/gm), which coincided with the values reported previously. Because of it's short half life and low radiation dosage to the patients, sup(99m)Tc method will be recommended in the field of pediatrics or in patients with polycythemia or congestive heart failure, who are requested the repeated measurement of blood volume.

  19. Use of WebDAV to Support a Virtual File System in a Coalition Environment

    National Research Council Canada - National Science Library

    Bradney, Jeremiah A

    2006-01-01

    .... By enabling the use of WebDAV in MYSEA, this thesis provides a means for fulfilling the above requirement for secure remote access by creating a virtual web-based file system accessible from the MYSEA MLS network...

  20. No detectable nephrotoxic side effect using a dimer, non-ionic contrast media in cerebral perfusion computed tomography in case of suspected brain ischemia

    International Nuclear Information System (INIS)

    Petrik, M.; Weigel, C.; Kirsch, M.; Hosten, N.

    2005-01-01

    Purpose: In suspected brain ischemia, the perfusion cerebral computed tomography (cCT) should be performed with the lowest amount of contrast media to avoid a contrast media induced nephropathy (CIN) even if the patient already is in renal failure. We were interested to find the best parameters for this examination. Material and methods: From February 2000 to March 2003, 138 patients (58 females, 80 males, mean age 66.8 years) underwent cCT-perfusion immediately after the admission to our stroke unit. Of these patients, 62% (n=86) had normal renal function and 38% (n=52) renal failure (up to 381 μmol/l basic serum creatinine). We varied volume (20-80 ml), flow (5 vs. 7.2. ml/s) and concentration (270 vs. 320 ml/mg iodine) of a dimer, non-ionic contrast media (Visipaque registered ) to establish 5 groups. So we got patients receiving 6 g, 12 g, 16 g, 19 g and 25 g of iodine. After generating the perfusion maps, two radiologists reviewed the quality of the maps and scored it (1-5). We measured the serum creatinine before contrast application and at follow up cCt (days 3 and 7). Results: The quality of the maps increases with increasing amount of iodine. However, the diagnostic result was not significantly better using more than about 16 g of iodine (e.g., 60 ml-7.2 ml/s - 270 mg/ml) in cCT-perfusion studies. Only one patient had a pathologic increase in serum creatinine (day 1: 93; day 4: 146 μmol/l) but died at day 5 because of massive co-morbidity and septic pneumonia. No CIN occurred even in the patient group with pre-existent renal failure. Conclusions: About 60 ml contrast media and a moderate flow rate of about 7 ml/s ensure good results in perfusion-cCT, even if the patients have poor blood circulation or arteriosclerosis. The use of a dimer, non-ionic contrast media (range of 6-25 g iodine) seems to minimize the risk of CIN in the daily routine. (orig.)

  1. Comprehensive low-dose imaging of carotid and coronary arteries with a single-injection dual-source CT angiography protocol

    International Nuclear Information System (INIS)

    Tognolini, A.; Arellano, C.S.; Marfori, W.; Heidari, G.; Sayre, J.W.; Krishnam, M.S.; Ruehm, S.G.

    2014-01-01

    Aim: To assess the feasibility of a fast single-bolus combined carotid and coronary computed tomography angiography (CTA) protocol in asymptomatic patients. Materials and methods: Thirty-three consecutive patients (18 women and 15 men) with a median age of 61 ± 14 years old (range 37–87 years) with known or suspected atherosclerotic disease were enrolled in this prospective study. A single breath-hold, single biphasic injection protocol (50 ml at 3 ml/s, 50 ml at 5 ml/s, 50 ml saline flush at 5 ml/s) was used for combined CTA imaging of the supra-aortic (SAA) and coronary arteries (CA) on a 64-slice dual-source CT (DSCT) machine. Helical CTA acquisition of the SAA was followed by prospective electrocardiography (ECG)-triggered coronary CTA. Subjective (four-point scale) image quality and objective signal-to-noise (SNR) and contrast-to-noise (CNR) measurements were performed. Vascular disease was graded on a four-point scale (grade 1: absent; grade 2: mild, grade 3: moderate; grade 4: severe). The radiation dose was recorded for each patient. Results: The average enhancement and subjective quality score of SAA and CA segments were 396 HU/358 HU and 1.2 ± 0.3/1.72 ± 0.4, respectively. The SNR was 27.1 ± 1.7 in the SAA and 21.6 ± 1.6 in the CA (p < 0.0001). The CNR was 18.1 ± 1.2 and 15.9 ± 1.8, respectively (p = 0.4). Four percent of SAA and 14% of CA segments (mostly due to peri-venous streak artefacts and small calibre, respectively) produced non-diagnostic images. SAA findings were as follows: 26/33 (79%) patients showed no disease and 6/33 (18%) had grade 2 and 1/33 (3%) had grade 3 disease. CA findings were as follows: 25/33 (76%) showed no disease and 6/33 (18%) patients had grade 2 and 2/33 (6%) had grade 3 disease. Five patients had disease in both districts. The average radiation dose for the combined CTA angiogram was 4.3 ± 0.6 mSv. Conclusion: A fast, low-dose combined DSCT angiography protocol appears technically feasible for imaging carotid and

  2. Phenotypes and genotypes of erythromycin-resistant Streptococcus pyogenes strains isolated from invasive and non-invasive infections from Mexico and the USA during 1999–2010

    Science.gov (United States)

    Villaseñor-Sierra, Alberto; Katahira, Eva; Jaramillo-Valdivia, Abril N.; de los Angeles Barajas-García, María; Bryant, Amy; Morfín-Otero, Rayo; Márquez-Díaz, Francisco; Tinoco, Juan Carlos; Sánchez-Corona, José; Stevens, Dennis L.

    2012-01-01

    Summary Objective To compare the prevalence, phenotypes, and genes responsible for erythromycin resistance among Streptococcus pyogenes isolates from Mexico and the USA. Methods Eighty-nine invasive and 378 non-invasive isolates from Mexico, plus 148 invasive, 21 non-invasive, and five unclassified isolates from the USA were studied. Susceptibilities to penicillin, erythromycin, clindamycin, ceftriaxone, and vancomycin were evaluated according to Clinical and Laboratory Standards Institute (CLSI) standards. Phenotypes of erythromycin resistance were identified by triple disk test, and screening for mefA, ermTR, and ermB genes was carried out by PCR. Results All isolates were susceptible to penicillin, ceftriaxone, and vancomycin. Erythromycin resistance was found in 4.9% of Mexican strains and 5.2% of USA strains. Phenotypes in Mexican strains were 95% M and 5% cMLS; in strains from the USA, phenotypes were 33.3% iMLS, 33.3% iMLS-D, and 33.3% M. Erythromycin resistance genes in strains from Mexico were mefA (95%) and ermB (5%); USA strains harbored ermTR (56%), mefA (33%), and none (11%). In Mexico, all erythromycin-resistant strains were non-invasive, whereas 89% of strains from the USA were invasive. Conclusions Erythromycin resistance continues to exist at low levels in both Mexico and the USA, although the genetic mechanisms responsible differ between the two nations. These genetic differences may be related to the invasive character of the S. pyogenes isolated. PMID:22217469

  3. Using performance tasks employing IOM patient safety competencies to introduce quality improvement processes in medical laboratory science education.

    Science.gov (United States)

    Golemboski, Karen; Otto, Catherine N; Morris, Susan

    2013-01-01

    In order to contribute to improved healthcare quality through patient-centered care, laboratory professionals at all levels of practice must be able to recognize the connection between non-analytical factors and laboratory analysis, in the context of patient outcomes and quality improvement. These practices require qualities such as critical thinking (CT), teamwork skills, and familiarity with the quality improvement process, which will be essential for the development of evidence-based laboratory science practice. Performance tasks (PT) are an educational strategy which can be used to teach and assess CT and teamwork, while introducing Medical Laboratory Science (MLS) students at both baccalaureate and advanced-practice levels to the concepts of quality improvement processes and patient outcomes research. PT presents students with complex, realistic scenarios which require the incorporation of subject-specific knowledge with competencies such as effective team communication, patient-centered care, and successful use of information technology. A PT with assessment rubric was designed for use in a baccalaureate-level MLS program to teach and assess CT and teamwork competency. The results indicated that, even when students were able to integrate subject-specific knowledge in creative ways, their understanding of teamwork and quality improvement was limited. This indicates the need to intentionally teach skills such as collaboration and quality system design. PT represent one of many strategies that may be used in MLS education to develop essential professional competencies, encourage expert practice, and facilitate quality improvement.

  4. Curcumin and Viscum album Extract Decrease Proliferation and Cell Viability of Soft-Tissue Sarcoma Cells: An In Vitro Analysis of Eight Cell Lines Using Real-Time Monitoring and Colorimetric Assays.

    Science.gov (United States)

    Harati, K; Behr, B; Daigeler, A; Hirsch, T; Jacobsen, F; Renner, M; Harati, A; Wallner, C; Lehnhardt, M; Becerikli, M

    2017-01-01

    The cytostatic effects of the polyphenol curcumin and Viscum album extract (VAE) were assessed in soft-tissue sarcoma (STS) cells. Eight human STS cell lines were used: fibrosarcoma (HT1080), liposarcoma (SW872, T778, MLS-402), synovial sarcoma (SW982, SYO1, 1273), and malignant fibrous histiocytoma (U2197). Primary human fibroblasts served as control cells. Cell proliferation, viability, and cell index (CI) were analyzed by BrdU assay, MTT assay, and real-time cell analysis (RTCA). As indicated by BrdU and MTT, curcumin significantly decreased the cell proliferation of five cell lines (HT1080, SW872, SYO1, 1273, and U2197) and the viability of two cell lines (SW872 and SW982). VAE led to significant decreases of proliferation in eight cell lines (HT1080, SW872, T778, MLS-402, SW982, SYO1, 1293, and U2197) and reduced viability in seven STS lines (HT1080, SW872, T778, MLS-402, SW982, SYO1, and 1273). As indicated by RTCA for 160 h, curcumin decreased the CI of all synovial sarcoma cell lines as well as T778 and HT1080. VAE diminished the CI in most of the synovial sarcoma (SW982, SYO1) and liposarcoma (SW872, T778) cell lines as well as HT1080. Primary fibroblasts were not affected adversely by the two compounds in RTCA. Curcumin and VAE can inhibit the proliferation and viability of STS cells.

  5. Processing multilevel secure test and evaluation information

    Science.gov (United States)

    Hurlburt, George; Hildreth, Bradley; Acevedo, Teresa

    1994-07-01

    The Test and Evaluation Community Network (TECNET) is building a Multilevel Secure (MLS) system. This system features simultaneous access to classified and unclassified information and easy access through widely available communications channels. It provides the necessary separation of classification levels, assured through the use of trusted system design techniques, security assessments and evaluations. This system enables cleared T&E users to view and manipulate classified and unclassified information resources either using a single terminal interface or multiple windows in a graphical user interface. TECNET is in direct partnership with the National Security Agency (NSA) to develop and field the MLS TECNET capability in the near term. The centerpiece of this partnership is a state-of-the-art Concurrent Systems Security Engineering (CSSE) process. In developing the MLS TECNET capability, TECNET and NSA are providing members, with various expertise and diverse backgrounds, to participate in the CSSE process. The CSSE process is founded on the concepts of both Systems Engineering and Concurrent Engineering. Systems Engineering is an interdisciplinary approach to evolve and verify an integrated and life cycle balanced set of system product and process solutions that satisfy customer needs (ASD/ENS-MIL STD 499B 1992). Concurrent Engineering is design and development using the simultaneous, applied talents of a diverse group of people with the appropriate skills. Harnessing diverse talents to support CSSE requires active participation by team members in an environment that both respects and encourages diversity.

  6. process for K-shell ionization of atoms

    Indian Academy of Sciences (India)

    Department of Physics, College of Science Campus, M.L.S. University, Udaipur 313 002, ... been expressed as a product of kinematical factors and atomic structure functions. The ..... AL on energy is through two factors in an involved way.

  7. David Nolfi Receives NAHRS Award for Professional Excellence

    Directory of Open Access Journals (Sweden)

    Maureen Diana Sasso

    2013-09-01

    Full Text Available News AnnouncementDavid A. Nolfi, MLS, AHIP, Health Sciences Librarian & Library Assessment Coordinator at Duquesne University’s Gumberg Library, received the 2013 NAHRS Award for Professional Excellence at the One Health Conference in Boston, MA.

  8. Supporting Urban Energy Efficiency with Volunteered Roof Information and the Google Maps API

    Directory of Open Access Journals (Sweden)

    Bilal Abdulkarim

    2014-10-01

    Full Text Available The Heat Energy Assessment Technologies (HEAT project uses high-resolution airborne thermal imagery, Geographic Object-Based Image Analysis (GEOBIA, and a Geoweb environment to allow the residents of Calgary, Alberta, Canada to visualize the amount and location of waste heat leaving their houses, communities, and the city. To ensure the accuracy of these measures, the correct emissivity of roof materials needs to be known. However, roof material information is not readily available in the Canadian public domain. To overcome this challenge, a unique Volunteered Geographic Information (VGI application was developed using Google Street View that engages citizens to classify the roof materials of single dwelling residences in a simple and intuitive manner. Since data credibility, quality, and accuracy are major concerns when using VGI, a private Multiple Listing Services (MLS dataset was used for cross-verification. From May–November 2013, 1244 volunteers from 85 cities and 14 countries classified 1815 roofs in the study area. Results show (I a 72% match between the VGI and MLS data; and (II in the majority of cases, roofs with greater than, or equal to five contributions have the same material defined in both datasets. Additionally, this research meets new challenges to the GEOBIA community to incorporate existing GIS vector data within an object-based workflow and engages the public to provide volunteered information for urban objects from which new geo-intelligence is created in support of urban energy efficiency.

  9. Molecular accessibility in solvent swelled coals. Quarterly report, [September--November, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Kispert, L.D.

    1993-11-01

    This quarter, experiments were performed on the use of binary swelling solvents in molecular accessibility in coal conversion. These experiments consisted of accessibility measurements of spin probe VII (TEMPAMINE) in Toluene swelled Illinois No. 6 APCS coal. The toluene was spiked with amounts of pyridine which ranged in concentration from 500 ppm to 10%. The experiments were done in triplicate to gain information about the experimental error involved in the procedure. It was shown that oscillations occur in the concentration of spin probe retained as the amount of pyridine that is added to the swelling solvent is increased. These oscillations decrease in intensity as the concentration of pyridine in the solvent solution is increased up to 2% pyridine (0.2mLs pyridine in 10mLs toluene). From a 2% pyridine concentration to a 5% concentration, there is no significant change in the retention of spin probe VII. An increase in retention is observed when the concentration of pyridine is increased to 6% and 7% successively, followed by a large decrease at 8% and 9% pyridine. The largest changes in spin probe retention are observed for concentrations of pyridine less than 0.5%. A three fold increase in spin probe retention is observed upon the addition of 500 ppm pyridine in the toluene swelling solvent, which indicates that small amounts of a strong swelling solvent could be used to improve molecular accessibility 91% in coals swelled in an otherwise weak swelling solvent.

  10. Myxoid Liposarcoma: Prognostic Factors and Metastatic Pattern in a Series of 148 Patients Treated at a Single Institution

    Directory of Open Access Journals (Sweden)

    Francesco Muratori

    2018-01-01

    Full Text Available Objectives. The authors reported a retrospective study on myxoid liposarcomas (MLs, evaluating factors that may influence overall survival (OS, local recurrence-free survival (LRFS, metastasis-free survival (MFS, and analyzing the metastatic pattern. Methods. 148 MLs were analyzed. The sites of metastases were investigated. Results. Margins (p = 0.002, grading (p = 0,0479, and metastasis (p < 0,0001 were significant risk factors affecting overall survival (OS. Type of presentation (p = 0.0243, grading (p = 0,0055, margin (p = 0.0001, and local recurrence (0.0437 were risk factors on metastasis-free survival (MFS. Authors did not observe statistically significant risk factors for local recurrence-free survival (LRFS and reported 55% extrapulmonary metastases and 45% pulmonary metastases. Conclusion. Margins, grading, presentation, local recurrence, and metastasis were prognostic factors. Extrapulmonary metastases were more frequent in myxoid liposarcoma.

  11. SENSOR-TOPOLOGY BASED SIMPLICIAL COMPLEX RECONSTRUCTION FROM MOBILE LASER SCANNING

    Directory of Open Access Journals (Sweden)

    S. Guinard

    2018-05-01

    Full Text Available We propose a new method for the reconstruction of simplicial complexes (combining points, edges and triangles from 3D point clouds from Mobile Laser Scanning (MLS. Our main goal is to produce a reconstruction of a scene that is adapted to the local geometry of objects. Our method uses the inherent topology of the MLS sensor to define a spatial adjacency relationship between points. We then investigate each possible connexion between adjacent points and filter them by searching collinear structures in the scene, or structures perpendicular to the laser beams. Next, we create triangles for each triplet of self-connected edges. Last, we improve this method with a regularization based on the co-planarity of triangles and collinearity of remaining edges. We compare our results to a naive simplicial complexes reconstruction based on edge length.

  12. 424 Comparative Studies on the Larvicidal Action of Novaluron ...

    African Journals Online (AJOL)

    FIRST LADY

    2011-01-18

    Jan 18, 2011 ... Although, successful control of mosquito vectors with. Malathion ... containing 500mls of distilled water and allowed to hatch to 1st instar larvae and kept to .... and the rate of inhibition of emergence increased with increased.

  13. Mean vertical wind in the mesosphere-lower thermosphere region (80–120 km deduced from the WINDII observations on board UARS

    Directory of Open Access Journals (Sweden)

    V. Fauliot

    1997-09-01

    Full Text Available The WINDII interferometer placed on board the Upper Atmosphere Research Satellite measures temperature and wind from the O(1S green-line emission in the Earth's mesosphere and lower thermosphere. It is a remote-sensing instrument providing the horizontal wind components. In this study, the vertical winds are derived using the continuity equation. Mean wind annually averaged at equinoxes and solstices is shown. Ascendance and subsidence to the order of 1–2 cm s–1 present a seasonal occurrence at the equator and tropics. Zonal Coriolis acceleration and adiabatic heating and cooling rate associated to the mean meridional and vertical circulations are evaluated. The line emission rate measured together with the horizontal wind shows structures in altitude and latitude correlated with the meridional and vertical wind patterns. The effect of wind advection is discussed.

  14. Associateship | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Singh, Dr Arvind Ph.D. (MLS University). Date of birth: 30 June 1983. Specialization: Ocean Biogeochemistry, Anthropogenic Impacts on Marine Nitrogen Cycling, Stable Isotopes Address: Geoscience Division, Physical Research Laboratory, Navrangpura, Ahmedabad 380 009, Gujarat Contact: Office: (079) 2631 4366

  15. The major stratospheric final warming in 2016: dispersal of vortex air and termination of Arctic chemical ozone loss

    Directory of Open Access Journals (Sweden)

    G. L. Manney

    2016-12-01

    Full Text Available The 2015/16 Northern Hemisphere winter stratosphere appeared to have the greatest potential yet seen for record Arctic ozone loss. Temperatures in the Arctic lower stratosphere were at record lows from December 2015 through early February 2016, with an unprecedented period of temperatures below ice polar stratospheric cloud thresholds. Trace gas measurements from the Aura Microwave Limb Sounder (MLS show that exceptional denitrification and dehydration, as well as extensive chlorine activation, occurred throughout the polar vortex. Ozone decreases in 2015/16 began earlier and proceeded more rapidly than those in 2010/11, a winter that saw unprecedented Arctic ozone loss. However, on 5–6 March 2016 a major final sudden stratospheric warming ("major final warming", MFW began. By mid-March, the mid-stratospheric vortex split after being displaced far off the pole. The resulting offspring vortices decayed rapidly preceding the full breakdown of the vortex by early April. In the lower stratosphere, the period of temperatures low enough for chlorine activation ended nearly a month earlier than that in 2011 because of the MFW. Ozone loss rates were thus kept in check because there was less sunlight during the cold period. Although the winter mean volume of air in which chemical ozone loss could occur was as large as that in 2010/11, observed ozone values did not drop to the persistently low values reached in 2011.We use MLS trace gas measurements, as well as mixing and polar vortex diagnostics based on meteorological fields, to show how the timing and intensity of the MFW and its impact on transport and mixing halted chemical ozone loss. Our detailed characterization of the polar vortex breakdown includes investigations of individual offspring vortices and the origins and fate of air within them. Comparisons of mixing diagnostics with lower-stratospheric N2O and middle-stratospheric CO from MLS (long-lived tracers show rapid vortex erosion and

  16. Mean vertical wind in the mesosphere-lower thermosphere region (80–120 km deduced from the WINDII observations on board UARS

    Directory of Open Access Journals (Sweden)

    V. Fauliot

    Full Text Available The WINDII interferometer placed on board the Upper Atmosphere Research Satellite measures temperature and wind from the O(1S green-line emission in the Earth's mesosphere and lower thermosphere. It is a remote-sensing instrument providing the horizontal wind components. In this study, the vertical winds are derived using the continuity equation. Mean wind annually averaged at equinoxes and solstices is shown. Ascendance and subsidence to the order of 1–2 cm s–1 present a seasonal occurrence at the equator and tropics. Zonal Coriolis acceleration and adiabatic heating and cooling rate associated to the mean meridional and vertical circulations are evaluated. The line emission rate measured together with the horizontal wind shows structures in altitude and latitude correlated with the meridional and vertical wind patterns. The effect of wind advection is discussed.

  17. Statistical inference for the within-device precision of quantitative measurements in assay validation.

    Science.gov (United States)

    Liu, Jen-Pei; Lu, Li-Tien; Liao, C T

    2009-09-01

    Intermediate precision is one of the most important characteristics for evaluation of precision in assay validation. The current methods for evaluation of within-device precision recommended by the Clinical Laboratory Standard Institute (CLSI) guideline EP5-A2 are based on the point estimator. On the other hand, in addition to point estimators, confidence intervals can provide a range for the within-device precision with a probability statement. Therefore, we suggest a confidence interval approach for assessment of the within-device precision. Furthermore, under the two-stage nested random-effects model recommended by the approved CLSI guideline EP5-A2, in addition to the current Satterthwaite's approximation and the modified large sample (MLS) methods, we apply the technique of generalized pivotal quantities (GPQ) to derive the confidence interval for the within-device precision. The data from the approved CLSI guideline EP5-A2 illustrate the applications of the confidence interval approach and comparison of results between the three methods. Results of a simulation study on the coverage probability and expected length of the three methods are reported. The proposed method of the GPQ-based confidence intervals is also extended to consider the between-laboratories variation for precision assessment.

  18. Cloud ice: A climate model challenge with signs and expectations of progress

    Science.gov (United States)

    Waliser, Duane E.; Li, Jui-Lin F.; Woods, Christopher P.; Austin, Richard T.; Bacmeister, Julio; Chern, Jiundar; Del Genio, Anthony; Jiang, Jonathan H.; Kuang, Zhiming; Meng, Huan; Minnis, Patrick; Platnick, Steve; Rossow, William B.; Stephens, Graeme L.; Sun-Mack, Szedung; Tao, Wei-Kuo; Tompkins, Adrian M.; Vane, Deborah G.; Walker, Christopher; Wu, Dong

    2009-04-01

    Present-day shortcomings in the representation of upper tropospheric ice clouds in general circulation models (GCMs) lead to errors in weather and climate forecasts as well as account for a source of uncertainty in climate change projections. An ongoing challenge in rectifying these shortcomings has been the availability of adequate, high-quality, global observations targeting ice clouds and related precipitating hydrometeors. In addition, the inadequacy of the modeled physics and the often disjointed nature between model representation and the characteristics of the retrieved/observed values have hampered GCM development and validation efforts from making effective use of the measurements that have been available. Thus, even though parameterizations in GCMs accounting for cloud ice processes have, in some cases, become more sophisticated in recent years, this development has largely occurred independently of the global-scale measurements. With the relatively recent addition of satellite-derived products from Aura/Microwave Limb Sounder (MLS) and CloudSat, there are now considerably more resources with new and unique capabilities to evaluate GCMs. In this article, we illustrate the shortcomings evident in model representations of cloud ice through a comparison of the simulations assessed in the Intergovernmental Panel on Climate Change Fourth Assessment Report, briefly discuss the range of global observational resources that are available, and describe the essential components of the model parameterizations that characterize their "cloud" ice and related fields. Using this information as background, we (1) discuss some of the main considerations and cautions that must be taken into account in making model-data comparisons related to cloud ice, (2) illustrate present progress and uncertainties in applying satellite cloud ice (namely from MLS and CloudSat) to model diagnosis, (3) show some indications of model improvements, and finally (4) discuss a number of

  19. Impacts of the January 2005 solar particle events on middle atmospheric chlorine species

    Science.gov (United States)

    Winkler, Holger; Sinnhuber, Miriam; Notholt, Justus; Maik Wissing, Jan; Kallenrode, May-Britt; Santee, Michelle

    It is well established that solar particle events (SPEs) are sources of significant chemical dis-turbances in the Earth's polar atmosphere. The observed SPE effects on nitrogen, hydrogen and oxygen compounds have been investigated in some detail in recent years, and they can be reproduced by atmospheric models using basic parametrizations for NOx and HOx produc-tion as a funtion of the particle impact ionisation. However, there are considerable differences between model predictions and measurements concerning several other trace gases including chlorine species. Two major SPEs occurred on January 17, and January 20, 2005. The latter had an exceptionally hard energy spectrum which caused maximum particle impact ionization at stratospheric altitudes. The Microwave Limb Sounder (MLS) instrument on-board the Aura satellite has measured a short-term decrease of HCl in the northern polar region corresponding to January 2005 SPEs. The peak HCl depletion is ˜300 ppt at 35-40 km. This is comparable to the depletion of messopheric HCl observed by the HALOE instrument during the July 2000 SPE. We will present simulation results of the University of Bremen Ion Chemistry (UBIC) model for the SPEs in January 2005 focusing on chlorine species. The simulations indicate that the observed short-term decrease of middle atmospheric HCl is due to a conversion into active chlorine species such as Cl, ClO and HOCl. The magnitude of the observed HCl loss can only be reproduced if reactions of negative chlorine species and the production of O(1 D) from the reaction N(2 D) + O2 are taken into account. The model results will be compared to MLS/Aura data of HCl, HOCl and ClO. Additionally, the impacts of the observed chlorine activation, e.g. on ozone, will be assessed.

  20. Measurements of total suspended matter - How does salinity and the amount of rinse water influence the results; Maetning av totalt suspenderat material - Hur paaverkar salthalt och maengden skoeljvatten resultatet

    Energy Technology Data Exchange (ETDEWEB)

    Hall, Bjoern (Bjoern Hall, Miljoe och Foerbraenningskemi, Onsala (Sweden))

    2010-03-15

    Under regulations for incineration of waste NFS 2002:28 total suspended matter (tsm) in wastewater from incineration plants are analyzed by daily sampling measurement or by representative flow-proportional 24-hour test. It has been shown that many plants that analyzes the suspended matter according to EN 872:2005 are having trouble keeping their conditions for suspended solids constant. This applies mainly to plants rated for a high chloride content in the closing process. Waste Sweden has for years drawn attention to this problem and have with a joint working group with representatives from the Swedish waste incineration plants tried to obtain a better understanding of this phenomenon. The basic question is whether the water from the facilities in question really contain high levels of tsm or if there is something else behind the observed concentrations. The results from this study suggest that the most important factor is the salinity and the amount of rinse water used in the analysis. Under the standard, all samples are washed with 2 x 20 ml of water. If salinity exceeds 1000 mg/l, a further 3 x 50 ml used. How this process is this implemented in practice varies from laboratory to laboratory and there is no laboratory that regularly measure the salinity of the sample. It is not specified especially when submitting the sample uses most of the labs normal rinse water of 2 x 20 ml. The findings also indicate that the samples with very high salinities the standard stipulated 190 mls is not enough. This would likely lead to that further rinse water is needed. In order to establish safe Several measurements would be needed to confirm this assumption. A relatively simple way to obtain an idea of the salinity of the test is to measure its conductivity. Accordingly, this could be a first step on to get a more consistent performance than is the case at present

  1. searchSCF: Using MongoDB to Enable Richer Searches of Locally Hosted Science Data Repositories

    Science.gov (United States)

    Knosp, B.

    2016-12-01

    Science teams today are in the unusual position of almost having too much data available to them. Modern sensors and models are capable of outputting terabytes of data per day, which can make it difficult to find specific subsets of data. The sheer size of files can also make it time consuming to retrieve this big data from national data archive centers. Thus, many science teams choose to store what data they can on their local systems, but they are not always equipped with tools to help them intelligently organize and search their data. In its local data repository, the Aura Microwave Limb Sounder (MLS) science team at NASA's Jet Propulsion Laboratory has collected over 300TB of atmospheric science data from 71 missions/models that aid in validation, algorithm development, and research activities. When the project began, the team developed a MySQL database to aid in data queries, but this database was only designed to keep track of MLS and a few ancillary data sets, leving much of the data uncatalogued. The team has also seen database query time rise over the life of the mission. Even though the MLS science team's data holdings are not the size of a national data center's, team members still need tools to help them discover and utilize the data that they have on-hand. Over the past year, members of the science team have been looking for solutions to (1) store information on all the data sets they have collected in a single database, (2) store more metadata about each data file, (3) develop queries that can find relationships among these disparate data types, and (4) plug any new functions developed around this database into existing analysis, visualization, and web tools, transparently to users. In this presentation, I will discuss the searchSCF package that is currently under development. This package includes a NoSQL database management system (MongoDB) and a set of Python tools that both ingests data into the database and supports user queries. I will also

  2. GENERAL SURGERY

    African Journals Online (AJOL)

    mean time to first surgery post burn was 11.5 days with a median volume of 0.73 mls/kg/% ..... Mode. Mean (SD). Upper limit. 95% CI. Lower limit. 95% CI. Mode. Elective surgery .... evaluating single-unit red blood cell transfusions in reducing.

  3. Understanding Traveler Behavior : The Psychology Behind Managed Lane Use

    Science.gov (United States)

    2012-07-01

    Recent analysis of Katy Freeway/Managed Lane (ML) travelers and I-394 Freeway/High : Occupancy Toll (HOT) lane traveler data has found that many travelers pay to use these HOT : lanes and MLs when adjacent toll-free lanes are operating at nearly the ...

  4. Multilevel architectures for electronic document retrieval

    International Nuclear Information System (INIS)

    Rome, J.A.; Tolliver, J.S.

    1997-01-01

    Traditionally, most classified computer systems run at the highest level of any of the data on the system, and all users must be cleared to this security level. This architecture precludes the use of low-level (pay and clearance) personnel for such tasks as data entry, and makes sharing data with other entities difficult. The government is trying to solve this problem by the introduction of multilevel-secure (MLS) computer systems. In addition, wherever possible, there is pressure to use commercial off-the-shelf software (COTS) to improve reliability, and to reduce purchase and maintenance costs. This paper presents two architectures for an MLS electronic document retrieval system using COTS products. Although the authors believe that the resulting systems represent a real advance in usability, scaleability, and scope, the disconnect between existing security rules and regulations and the rapidly-changing state of technology will make accreditation of such systems a challenge

  5. AUTOMATIC RAILWAY POWER LINE EXTRACTION USING MOBILE LASER SCANNING DATA

    Directory of Open Access Journals (Sweden)

    S. Zhang

    2016-06-01

    Full Text Available Research on power line extraction technology using mobile laser point clouds has important practical significance on railway power lines patrol work. In this paper, we presents a new method for automatic extracting railway power line from MLS (Mobile Laser Scanning data. Firstly, according to the spatial structure characteristics of power-line and trajectory, the significant data is segmented piecewise. Then, use the self-adaptive space region growing method to extract power lines parallel with rails. Finally use PCA (Principal Components Analysis combine with information entropy theory method to judge a section of the power line whether is junction or not and which type of junction it belongs to. The least squares fitting algorithm is introduced to model the power line. An evaluation of the proposed method over a complicated railway point clouds acquired by a RIEGL VMX450 MLS system shows that the proposed method is promising.

  6. Glomerular function in sickle cell disease patients during crisis.

    Science.gov (United States)

    Aderibigbe, A; Arije, A; Akinkugbe, O O

    1994-06-01

    An 8 month prospective study was carried out in 20 adult sickle cell disease (SCD) patients 16 sickle cell anaemia (Hbss) and 4 sickle cell Hbc disease (Hbsc); who had vaso-occlusive crises within the study period to determine the extent of the effect of sickle cell crisis on glomerular function in SCD patients during crisis. The male: female ratio was 1:57 and their mean age was 21.1 +/- 7.9 years. Creatinine clearance (CCr), as an index of glomerular function, was determined at the pre-crisis, crisis, 2 and 4 weeks post-crisis and at the end of the study period. The mean values of their CCr dropped from 113.37 +/- 33.80mls/min at pre-crisis stage to 96.39 +/- 30.13mls/min during crisis (p pre-crisis stage (p > 0.05). It is concluded that glomerular dysfunction in SCD patients during crisis is potentially reversible.

  7. Spread and burning behavior of continuous spill fires

    DEFF Research Database (Denmark)

    Zhao, Jinlong; Huang, Hong; Jomaas, Grunde

    2017-01-01

    Spill fire experiments with continuous discharge on a fireproof glass sheet were conducted to improve the understanding of spill fire spread and burning. Ethanol was used as the fuel and the discharge rate was varied from 2.8. mL/s to 7.6. mL/s. Three ignition conditions were used...... in the experiments; no ignition, instantaneous ignition and delayed ignition. The spread rate, regression rate, penetrated thermal radiation and the temperature of the bottom glass were analyzed. The experiments clearly show the entire spread process for spill fires. Further, the regression rate of spill fires...... at the quasi-steady burning was lower than that of pool fires and the ratio of the spill fires' regression rate to the pool fires' regression rate was found to be approximately 0.89. With respect to the radiative penetration and the heat conduction between the fuel layer and the glass, a regression rate...

  8. Using PIV to determine relative pressures in a stenotic phantom under steady flow based on the pressure-poisson equation.

    Science.gov (United States)

    Khodarahmi, Iman; Shakeri, Mostafa; Sharp, M; Amini, Amir A

    2010-01-01

    Pressure gradient across a Gaussian-shaped 87% area stenosis phantom was estimated by solving the pressure Poisson equation (PPE) for a steady flow mimicking the blood flow through the human iliac artery. The velocity field needed to solve the pressure equation was obtained using particle image velocimetry (PIV). A steady flow rate of 46.9 ml/s was used, which corresponds to a Reynolds number of 188 and 595 at the inlet and stenosis throat, respectively (in the range of mean Reynolds number encountered in-vivo). In addition, computational fluid dynamics (CFD) simulation of the same flow was performed. Pressure drops across the stenosis predicted by PPE/PIV and CFD were compared with those measured by a pressure catheter transducer. RMS errors relative to the measurements were 17% and 10% for PPE/PIV and CFD, respectively.

  9. Internal urethrotomy in patients with recurrent urethral stricture after buccal mucosa graft urethroplasty.

    Science.gov (United States)

    Rosenbaum, Clemens M; Schmid, Marianne; Ludwig, Tim A; Kluth, Luis A; Reiss, Philip; Dahlem, Roland; Engel, Oliver; Chun, Felix K-H; Riechardt, Silke; Fisch, Margit; Ahyai, Sascha A

    2015-09-01

    To determine the success rate of direct vision internal urethrotomy (DVIU) in the treatment of short stricture recurrence after buccal mucosa graft urethroplasty (BMGU). Patients who underwent DVIU for the treatment of short, "veil-like" recurrent urethral strictures (urethroplasty database. Stricture recurrence was defined as maximum flow rate (Q max) <15 ml/s and a consecutively verified stricture in a combined retro- and antegrade voiding cystography or cystoscopy at a follow-up visit. The success rate of DVIU was assessed by Kaplan-Meier analysis. Univariable Cox regression analyses evaluated risk factors for stricture recurrence following DVIU. Forty-three patients underwent DVIU for short stricture recurrence after BMGU for bulbar (81.3 %), penile (14.0 %) and membranous (4.7 %) strictures. Relapse had occurred proximally to the buccal mucosa graft in 28 (65.1 %) and distally in 12 (27.9 %) patients, respectively. At a mean follow-up of 11.7 (±9.7) months, stricture recurrence was observed in 48.8 % of our patients. Stricture recurrence was significantly associated with weak urinary stream (9.3 ml/s vs. no recurrence 19.5 ml/s) and patient dissatisfaction (66.7 % vs. no recurrence 18.1 %; both p < 0.001). The overall success rate was 60.5 % 15 months after DVIU. The main limitations of this study are its retrospective design, the small sample size and the short follow-up. DVIU after BMGU showed a moderate success rate and therefore might be a viable treatment option in selected patients with very short strictures after BMGU. However, longer follow-up is warranted to prove long-term effectiveness.

  10. Effect of IR Laser on Myoblasts: Prospects of Application for Counteracting Microgravity-Induced Muscle Atrophy

    Science.gov (United States)

    Monici, Monica; Cialdai, Francesca; Romano, Giovanni; Corsetto, Paola Antonia; Rizzo, Angela Maria; Caselli, Anna; Ranaldi, Francesco

    2013-02-01

    Microgravity-induced muscle atrophy is a problem of utmost importance for the impact it may have on the health and performance of astronauts. Therefore, appropriate countermeasures are needed to prevent disuse atrophy and favour muscle recovery. Muscle atrophy is characterized by loss of muscle mass and strength, and a shift in substrate utilization from fat to glucose, that leads to a reduced metabolic efficiency and enhanced fatigability. Laser therapy is already used in physical medicine and rehabilitation to accelerate muscle recovery and in sports medicine to prevent damages produced by metabolic disturbances and inflammatory reactions after heavy exercise. The aim of the research we present was to get insights on possible benefits deriving from the application of an advanced infrared laser system to counteract deficits of muscle energy metabolism and stimulate the recovery of the hypotrophic tissue. The source used was a Multiwave Locked System (MLS) laser, which combines continuous and pulsed emissions at 808 nm and 905 nm, respectively. We studied the effect of MLS treatment on morphology and energy metabolism of C2C12 cells, a widely accepted myoblast model, previously exposed to microgravity conditions modelled by a Random Positioning Machine. The MLS laser treatment was able to restore basal levels of serine/threonine protein phosphatase activity and to counteract cytoskeletal alterations and increase in glycolytic enzymes activity that occurred following the exposure to modelled microgravity. In conclusion, the results provide interesting insights for the application of infrared laser in the treatment of muscle atrophy.

  11. Mechanisms of Mixed-Layer Salinity Seasonal Variability in the Indian Ocean

    Science.gov (United States)

    Köhler, Julia; Serra, Nuno; Bryan, Frank O.; Johnson, Benjamin K.; Stammer, Detlef

    2018-01-01

    Based on a joint analysis of an ensemble mean of satellite sea surface salinity retrievals and the output of a high-resolution numerical ocean circulation simulation, physical processes are identified that control seasonal variations of mixed-layer salinity (MLS) in the Indian Ocean, a basin where salinity changes dominate changes in density. In the northern and near-equatorial Indian Ocean, annual salinity changes are mainly driven by respective changes of the horizontal advection. South of the equatorial region, between 45°E and 90°E, where evaporation minus precipitation has a strong seasonal cycle, surface freshwater fluxes control the seasonal MLS changes. The influence of entrainment on the salinity variance is enhanced in mid-ocean upwelling regions but remains small. The model and observational results reveal that vertical diffusion plays a major role in precipitation and river runoff dominated regions balancing the surface freshwater flux. Vertical diffusion is important as well in regions where the advection of low salinity leads to strong gradients across the mixed-layer base. There, vertical diffusion explains a large percentage of annual MLS variance. The simulation further reveals that (1) high-frequency small-scale eddy processes primarily determine the salinity tendency in coastal regions (in particular in the Bay of Bengal) and (2) shear horizontal advection, brought about by changes in the vertical structure of the mixed layer, acts against mean horizontal advection in the equatorial salinity frontal regions. Observing those latter features with the existing observational components remains a future challenge.

  12. Forest inventory with terrestrial LiDAR

    NARCIS (Netherlands)

    Bauwens, Sébastien; Bartholomeus, Harm; Calders, Kim; Lejeune, Philippe

    2016-01-01

    The application of static terrestrial laser scanning (TLS) in forest inventories is becoming more effective. Nevertheless, the occlusion effect is still limiting the processing efficiency to extract forest attributes. The use of a mobile laser scanner (MLS) would reduce this occlusion. In this

  13. Molecular Basis of Intrinsic Macrolide Resistance in the Mycobacterium tuberculosis Complex

    Czech Academy of Sciences Publication Activity Database

    Buriánková, Karolína; Doucet-Populaire, F.; Dorson, O.; Gondran, A.; Ghnassia, J. C.; Weiser, Jaroslav; Pernodet, J. L.

    2004-01-01

    Roč. 48, č. 1 (2004), s. 143-150 ISSN 0066-4804 R&D Projects: GA ČR GA204/00/1252 Institutional research plan: CEZ:AV0Z5020903 Keywords : ntm * mls * rrna Subject RIV: EE - Microbiology, Virology Impact factor: 4.216, year: 2004

  14. Information Hiding: an Annotated Bibliography

    Science.gov (United States)

    1999-04-13

    www.springer.de/catalog/html-files/deutsch/comp/3540619968. html>. [325] 063213, ‘A Multiversion Transaction Scheduler for Centralized Multilevel Se- cure...an MLS DBMS. The authors pro- pose getting around these problems by using multiversion schedulers. An abstract model is developed and shown to

  15. Global Gravity Wave Variances from Aura MLS: Characteristics and Interpretation

    Science.gov (United States)

    2008-12-01

    slight longitudinal variations, with secondary high- latitude peaks occurring over Greenland and Europe . As the QBO changes to the westerly phase, the...equatorial GW temperature variances from suborbital data (e.g., Eck- ermann et al. 1995). The extratropical wave variances are generally larger in the...emanating from tropopause altitudes, presumably radiated from tropospheric jet stream in- stabilities associated with baroclinic storm systems that

  16. Stratospheric ozone climatology and variability over a southern subtropical site: Reunion Island (21° S; 55° E

    Directory of Open Access Journals (Sweden)

    V. Sivakumar

    2007-11-01

    Full Text Available The study presents the climatological characteristics of stratospheric ozone observed over Reunion Island using in-situ (ozonesonde and SAOZ and satellite (UARS-HALOE, SAGE-II and TOMS measurements. It uses co-localised ozonesondes (from September 1992 to February 2005 and SAOZ measurements (from January 1993 to December 2004, SAGE-II data from October 1984 to February 1999 (~15 years, HALOE data from January 1991 to February 2005 (~15 years, and NIMBUS/TOMS data from January 1978 to December 2004 (27 years. The satellite measurements correspond to overpasses located nearby Reunion Island (21° S; 55° E. The height profiles of ozone concentration obtained from ozonesonde (0.5–29.5 km show less bias in comparison with the HALOE and SAGE-II measurements. Though, the satellite (HALOE and SAGE-II measurements underestimate the tropospheric ozone, they are in good agreement for the heights above 15 km. The bias between the measurements and the normalized ozone profile constructed from the ozonesonde and SAGE-II satellite measurement shows that the SAGE-II measurements are more accurate than the HALOE measurements in the lower stratosphere. The monthly variation of ozone concentration derived from ozonesonde and HALOE shows a nearly annual cycle with a maximum concentration during winter/spring and minimum concentration during summer/autumn months. The time evolution of total column ozone obtained from TOMS, SAOZ and the one computed from ozonesonde and SAGE-II, exhibits similar behaviour with analogous trends as above. The TOMS variation displays a higher value of total column ozone of about 3–5 DU (10% in comparison with the SAOZ and the integrated ozone from ozonesonde and SAGE-II.

  17. Changes in urination according to the sound of running water using a mobile phone application.

    Science.gov (United States)

    Kwon, Whi-An; Kim, Sung Han; Kim, Sohee; Joung, Jae Young; Chung, Jinsoo; Lee, Kang Hyun; Lee, Sang-Jin; Seo, Ho Kyung

    2015-01-01

    The sound of running water (SRW) has been effectively used for toilet training during toddlerhood. However, the effect of SRW on voiding functions in adult males with lower urinary tract symptoms (LUTS) has not been evaluated. To determine the effect of SRW on urination in male patients with LUTS, multiple voiding parameters of uroflowmetry with postvoid residual urine (PVR) were assessed according to the presence of SRW played by a mobile application. Eighteen consecutive male patients with LUTS were prospectively enrolled between March and April 2014. Uroflowmetry with PVR measured by a bladder scan was randomly performed once weekly for two consecutive weeks with and without SRW in a completely sealed room after pre-checked bladder volume was scanned to be more than 150 cc. SRW was played with river water sounds amongst relaxed melodies from a smartphone mobile application. The mean age of enrolled patients and their mean International Prostate Symptom Score (IPSS) were 58.9 ± 7.7 years (range: 46-70) and 13.1 ± 5.9, respectively. All patients had not been prescribed any medications, including alpha-blockers or anti-muscarinic agents, in the last 3 months. There was a significant increase in mean peak flow rate (PFR) with SRW in comparison to without SRW (15.7 mL/s vs. 12.3 mL/s, respectively, p = 0.0125). However, there were no differences in other uroflowmetric parameters, including PVR. The study showed that SRW from a mobile phone application may be helpful in facilitating voiding functions by increasing PFR in male LUTS patients.

  18. MDCT angiography of the pulmonary arteries: intravascular contrast enhancement does not depend on iodine concentration when injecting equal amounts of iodine at standardized iodine delivery rates

    International Nuclear Information System (INIS)

    Keil, S.; Plumhans, C.; Behrendt, F.F.; Das, M.; Muehlenbruch, G.; Mahnken, A.H.; Guenther, R.W.; Stanzel, S.; Seidensticker, P.; Knackstedt, C.; Wildberger, J.E.

    2008-01-01

    To compare the impact of iodine concentration using two different contrast materials (CM) at standardized iodine delivery rate (IDR) and overall iodine load in 16-multidetector-row-CT-angiography (MDCTA) of the pulmonary arteries of 192 patients with known or suspected pulmonary embolism. One hundred three patients (group A) received 148 ml of a CM containing 300 mg iodine/ml (Ultravist 300 trademark, BayerScheringPharma) at a flow rate of 4.9 ml/s. Eighty-nine patients (group B) received 120 ml of a CM with a concentration of 370 mg iodine/ml (Ultravist370 trademark) at a flow rate of 4.0 ml/s, resulting in a standardized IDR (∝1.5 gI/s) and the same overall amount of iodine (44.4 g). Both CM injections were followed by a saline chaser. Mean density values were determined in the pulmonary trunk, the ascending and the descending aorta, respectively. Applying repeated-measures ANOVA, no statistically significant differences between both MDCTA protocols were found (p=0.5790): the mean density in the pulmonary trunk was 355±116 Hounsfield Units (group A) and 358±115 (group B). The corresponding values for the ascending and descending aorta were 295±79 (group A) and 284±65 (group B) as well as 272±71 and 262±70. In conclusion, the use of standardized IDR and overall iodine load provides comparable intravascular CM density in pulmonary 16-MDCTA for delivering contrast materials with different iodine concentrations. (orig.)

  19. UARS Solar-Stellar Irradiance Comparison Experiment (SOLSTICE) Level 3BS V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The Solar-Stellar Irradiance Comparison Experiment (SOLSTICE) Level 3BS data product consists of daily, 1 nm resolution, solar spectral irradiances and selected...

  20. UARS Improved Stratospheric and Mesospheric Sounder (ISAMS) Level 3AL V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The Improved Stratospheric and Mesospheric Sounder (ISAMS) Level 3AL data product consists of daily, 4 degree increment latitude-ordered vertical profiles of...

  1. UARS Improved Stratospheric and Mesospheric Sounder (ISAMS) Level 3AT V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The Improved Stratospheric and Mesospheric Sounder (ISAMS) Level 3AT data product consists of daily, 65.536 second interval time-ordered vertical profiles of...

  2. UARS Cryogenic Limb Array Etalon Spectrometer (CLAES) Level 3AL V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The Cryogenic Limb Array Etalon Spectrometer (CLAES) Level 3AL data product consists of daily, 4 degree increment latitude-ordered vertical profiles of temperature...

  3. UARS Cryogenic Limb Array Etalon Spectrometer (CLAES) Level 3AT V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The Cryogenic Limb Array Etalon Spectrometer (CLAES) Level 3AT data product consists of daily, 65.536 second interval time-ordered vertical profiles of temperature...

  4. Moving least squares simulation of free surface flows

    DEFF Research Database (Denmark)

    Felter, C. L.; Walther, Jens Honore; Henriksen, Christian

    2014-01-01

    In this paper a Moving Least Squares method (MLS) for the simulation of 2D free surface flows is presented. The emphasis is on the governing equations, the boundary conditions, and the numerical implementation. The compressible viscous isothermal Navier–Stokes equations are taken as the starting ...

  5. Spatial Visualization as Mediating between Mathematics Learning Strategy and Mathematics Achievement among 8th Grade Students

    Science.gov (United States)

    Rabab'h, Belal; Veloo, Arsaythamby

    2015-01-01

    Jordanian 8th grade students revealed low achievement in mathematics through four periods (1999, 2003, 2007 & 2011) of Trends in International Mathematics and Science Study (TIMSS). This study aimed to determine whether spatial visualization mediates the affect of Mathematics Learning Strategies (MLS) factors namely mathematics attitude,…

  6. ORIGINAL ARTICLE Endovascular therapy for acute tumour-related ...

    African Journals Online (AJOL)

    safety of self-expanding Nitinol stents (Sinus XL, Optimed, Ettlingen,. Germany) in the ... 100 ml Imeron 350 via an antecubital vein in the left arm at a rate of 3 ml/s and a delay of ..... hand, blood flow is also possible from the contralateral side ...

  7. Assimilated ozone from EOS-Aura: Evaluation of the tropopause region and tropospheric columns

    NARCIS (Netherlands)

    Stajner, I.; Wargan, K.; Pawson, S.; Hayashi, H.; Chang, L.-P.; Hudman, R.C.; Froidevaux, L.; Livesey, N.J.; Levelt, P.F.; Thompson, A.M.; Tarasick, D.W.; Stübi, R.; Andersen, S.B.; Yela, M.; König-Langlo, G.; Schmidlin, F.J.; Witte, J.C.

    2008-01-01

    Retrievals from the Microwave Limb Sounder (MLS) and the Ozone Monitoring Instrument (OMI) on EOS-Aura were included in the Goddard Earth Observing System version 4 (GEOS-4) ozone data assimilation system. The distribution and daily to seasonal evolution of ozone in the stratosphere and troposphere

  8. A new type of axial-flux magnetic lead screw with inherent spring characteristic

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Xia, Yongming; Pan, Haipeng

    2016-01-01

    Magnetic Lead Screw (MLS) can transfer slow linear motion into fast rotary motion offering much higher force density than that of traditional linear permanent magnet machines. It has been developed for ocean wave energy harvester and active damper for electrical vehicles. In this paper, a new type...

  9. Adult posterior urethral valve: a case report

    Science.gov (United States)

    Kilciler, Mete; Basal, Seref; Irkilata, Hasan Cem; Zor, Murat; Istanbulluoglu, Mustafa Okan; Dayanc, Murat

    2010-01-01

    Introduction: Posterior urethral valve (PUV) is a congenital obstructive defect of the male urethra with an incidence of 1/8,000 to 1/25,000 live births. PUV is the most common cause of lower urinary tract obstruction in neonates. The diagnosis of PUV is usually made early, and PUV cases have rarely been detected in adults. Case presentation: Here we report the case of a 35 years old man presented with obstructive urinary symptoms. In spite of bladder neck rejection uroflowmetry pointed out infravesical obstruction with max. flow rate 9 ml/s and average flow rate 6 ml/s in uroflowmetry. During cystoscopy mild bladder trabeculation and resected bladder neck were seen. While the cystoscope was taken off, PUV were obtained. Conclusion: Since PUV is a rare condition in adults and the diagnosis of PUVs is also difficult in these groups we must consider this situation during evaluation of adult patients with obstructive symptoms especially during cystourethroscopy. PMID:20379394

  10. Adult posterior urethral valve: a case report

    Directory of Open Access Journals (Sweden)

    Dayanc, Murat

    2010-03-01

    Full Text Available Introduction: Posterior urethral valve (PUV is a congenital obstructive defect of the male urethra with an incidence of 1/8,000 to 1/25,000 live births. PUV is the most common cause of lower urinary tract obstruction in neonates. The diagnosis of PUV is usually made early, and PUV cases have rarely been detected in adults. Case presentation: Here we report the case of a 35 years old man presented with obstructive urinary symptoms. In spite of bladder neck rejection uroflowmetry pointed out infravesical obstruction with max. flow rate 9 ml/s and average flow rate 6 ml/s in uroflowmetry. During cystoscopy mild bladder trabeculation and resected bladder neck were seen. While the cystoscope was taken off, PUV were obtained. Conclusion: Since PUV is a rare condition in adults and the diagnosis of PUVs is also difficult in these groups we must consider this situation during evaluation of adult patients with obstructive symptoms especially during cystourethroscopy.

  11. Empirical Radiometric Normalization of Road Points from Terrestrial Mobile Lidar System

    Directory of Open Access Journals (Sweden)

    Tee-Ann Teo

    2015-05-01

    Full Text Available Lidar data provide both geometric and radiometric information. Radiometric information is influenced by sensor and target factors and should be calibrated to obtain consistent energy responses. The radiometric correction of airborne lidar system (ALS converts the amplitude into a backscatter cross-section with physical meaning value by applying a model-driven approach. The radiometric correction of terrestrial mobile lidar system (MLS is a challenging task because it does not completely follow the inverse square range function at near-range. This study proposed a radiometric normalization workflow for MLS using a data-driven approach. The scope of this study is to normalize amplitude of road points for road surface classification, assuming that road points from different scanners or strips should have similar responses in overlapped areas. The normalization parameters for range effect were obtained from crossroads. The experiment showed that the amplitude difference between scanners and strips decreased after radiometric normalization and improved the accuracy of road surface classification.

  12. Innovative Application of a Microlaryngeal Surgery Tube for difficult Airway Management in a Case of Down's Syndrome.

    Science.gov (United States)

    Gulabani, Michell; Gupta, Akhilesh; Bannerjee, Neerja Gaur; Sood, Rajesh; Dass, Prashant

    2016-04-01

    An 11-year-old male child, known case of down's syndrome with congenital oesophageal stricture was posted for oesophageal dilatation. Preoperative airway assessment revealed a high arched palate, receding mandible and Mallampati Score of 2. During surgery, after loss of consciousness which was described as loss of eyelash reflex and adequate jaw relaxation, direct laryngoscopy and endotracheal intubation was attempted with a cuffed endotracheal tube number 5.0mm ID (internal diameter). The endotracheal tube could not be negotiated smoothly, so 5.0mm ID uncuffed endotracheal tube was used which passed through easily, but on auscultation revealed a significant leak. Later, intubation via a Micro Laryngeal Surgery (MLS) cuffed tube 4.0mm ID was attempted. The MLS tube advanced smoothly and there was no associated leak on positive pressure ventilation. Thus by innovative thinking and avant-garde reasoning, a definitive airway device could be positioned with no other suitable alternative at hand.

  13. Analysis of phenotype, genotype and serotype distribution in erythromycin-resistant group B streptococci isolated from vaginal flora in Southern Ireland.

    LENUS (Irish Health Repository)

    Kiely, R A

    2010-02-01

    The screening of 2000 women of childbearing age in Cork between 2004 and 2006 produced 37 erythromycin-resistant group B streptococcus (GBS) isolates. PCR analysis was performed to determine the basis for erythromycin resistance. The ermTR gene was most frequently expressed (n = 19), followed by the ermB gene (n = 8). Four isolates harboured the mefA gene. Six isolates yielded no PCR products. Some phenotype-genotype correlation was observed. All isolates expressing the mefA gene displayed the M phenotype whilst all those expressing ermB displayed the constitutive macrolide resistance (cMLS(B)) phenotype. Of 19 isolates that expressed the ermTR gene, 16 displayed the inducible macrolide resistance (iMLS(B)) phenotype. Serotype analysis revealed that serotypes III and V predominated in these isolates. The identification of two erythromycin-resistant serotype VIII isolates among this collection represents the first reported finding of erythromycin resistance in this serotype. A single isolate was non-typable using two latex agglutination serotyping kits.

  14. Adsorption and transformation of selected human-used macrolide antibacterial agents with iron(III) and manganese(IV) oxides

    International Nuclear Information System (INIS)

    Feitosa-Felizzola, Juliana; Hanna, Khalil; Chiron, Serge

    2009-01-01

    The adsorption/transformation of two members (clarithromycin and roxithromycin) of the macrolide (ML) antibacterial agents on the surface of three environmental subsurface sorbents (clay, iron(III) and manganese(IV) oxy-hydroxides) was investigated. The adsorption fitted well to the Freundlich model with a high sorption capacity. Adsorption probably occurred through a surface complexation mechanism and was accompanied by slow degradation of the selected MLs. Transformation proceeded through two parallel pathways: a major pathway was the hydrolysis of the cladinose sugar, and to a lesser extent the hydrolysis of the lactone ring. A minor pathway was the N-dealkylation of the amino sugar. This study indicates that Fe(III) and Mn(IV) oxy-hydroxides in aquatic sediments may play an important role in the natural attenuation of MLs. Such an attenuation route yields a range of intermediates that might retain some of their biological activity. - Iron(III) and manganese(IV) oxy-hydroxides in aquatic sediments may play an important role in the natural attenuation of macrolide antibacterial agents

  15. Adsorption and transformation of selected human-used macrolide antibacterial agents with iron(III) and manganese(IV) oxides

    Energy Technology Data Exchange (ETDEWEB)

    Feitosa-Felizzola, Juliana [Laboratoire Chimie Provence, Aix-Marseille Universites-CNRS (UMR 6264), 3 place Victor Hugo, 13331 Marseille Cedex 3 (France); Hanna, Khalil [Laboratoire de Chimie Physique et Microbiologie pour l' Environnement, CNRS-Universite Henri Poincare-Nancy 1 (UMR 7564), 405 rue de Vandoeuvre, 54600 Villers-les-Nancy (France); Chiron, Serge [Laboratoire Chimie Provence, Aix-Marseille Universites-CNRS (UMR 6264), 3 place Victor Hugo, 13331 Marseille Cedex 3 (France)], E-mail: serge.chiron@univ-provence.fr

    2009-04-15

    The adsorption/transformation of two members (clarithromycin and roxithromycin) of the macrolide (ML) antibacterial agents on the surface of three environmental subsurface sorbents (clay, iron(III) and manganese(IV) oxy-hydroxides) was investigated. The adsorption fitted well to the Freundlich model with a high sorption capacity. Adsorption probably occurred through a surface complexation mechanism and was accompanied by slow degradation of the selected MLs. Transformation proceeded through two parallel pathways: a major pathway was the hydrolysis of the cladinose sugar, and to a lesser extent the hydrolysis of the lactone ring. A minor pathway was the N-dealkylation of the amino sugar. This study indicates that Fe(III) and Mn(IV) oxy-hydroxides in aquatic sediments may play an important role in the natural attenuation of MLs. Such an attenuation route yields a range of intermediates that might retain some of their biological activity. - Iron(III) and manganese(IV) oxy-hydroxides in aquatic sediments may play an important role in the natural attenuation of macrolide antibacterial agents.

  16. Versatile two-dimensional transition metal dichalcogenides

    DEFF Research Database (Denmark)

    Canulescu, Stela; Affannoukoué, Kévin; Döbeli, Max

    ), a strategy for the fabrication of 2D heterostructures must be developed. Here we demonstrate a novel approach for the bottom-up synthesis of TMDC monolayers, namely Pulsed Laser Deposition (PLD) combined with a sulfur evaporation beam. PLD relies on the use of a pulsed laser (ns pulse duration) to induce...... material transfer from a solid source (such as a sintered target of MoS2) to a substrate (such as Si or sapphire). The deposition rate in PLD is typically much less than a monolayer per pulse, meaning that the number of MLs can be controlled by a careful selection of the number of laser pulses......Two-dimensional transition metal dichalcogenides (2D-TMDCs), such as MoS2, have emerged as a new class of semiconducting materials with distinct optical and electrical properties. The availability of 2D-TMDCs with distinct band gaps allows for unlimited combinations of TMDC monolayers (MLs...

  17. Aluminothermic Reduction-Molten Salt Electrolysis Using Inert Anode for Oxygen and Al-Base Alloy Extraction from Lunar Soil Simulant

    Science.gov (United States)

    Xie, Kaiyu; Shi, Zhongning; Xu, Junli; Hu, Xianwei; Gao, Bingliang; Wang, Zhaowen

    2017-10-01

    Aluminothermic reduction-electrolysis using an inert anode process is proposed to extract oxygen and metals from Minnesota Lunar Simulant-1 (MLS-1). Effective aluminothermic reduction between dissolved MLS-1 and dissolved metal aluminum was achieved in cryolite salt media. The product phases obtained by aluminothermic reduction at 980°C for 4 h were Al, Si, and Al5FeSi, while the chemical components were 79.71 mass% aluminum, 12.03 mass% silicon, 5.91 mass% iron, and 2.35 mass% titanium. The cryolite salt containing Al2O3 was subsequently electrolyzed with Fe0.58-Ni0.42 inert anode at 960°C for 4 h. Oxygen was evolved at the anode with an anodic current efficiency of 78.28%. The results demonstrate that this two-step process is remarkably feasible for the extraterrestrial extraction of oxygen and metals. This process will help expand the existing in situ resource utilization methods.

  18. An Integrated GNSS/INS/LiDAR-SLAM Positioning Method for Highly Accurate Forest Stem Mapping

    Directory of Open Access Journals (Sweden)

    Chuang Qian

    2016-12-01

    Full Text Available Forest mapping, one of the main components of performing a forest inventory, is an important driving force in the development of laser scanning. Mobile laser scanning (MLS, in which laser scanners are installed on moving platforms, has been studied as a convenient measurement method for forest mapping in the past several years. Positioning and attitude accuracies are important for forest mapping using MLS systems. Inertial Navigation Systems (INSs and Global Navigation Satellite Systems (GNSSs are typical and popular positioning and attitude sensors used in MLS systems. In forest environments, because of the loss of signal due to occlusion and severe multipath effects, the positioning accuracy of GNSS is severely degraded, and even that of GNSS/INS decreases considerably. Light Detection and Ranging (LiDAR-based Simultaneous Localization and Mapping (SLAM can achieve higher positioning accuracy in environments containing many features and is commonly implemented in GNSS-denied indoor environments. Forests are different from an indoor environment in that the GNSS signal is available to some extent in a forest. Although the positioning accuracy of GNSS/INS is reduced, estimates of heading angle and velocity can maintain high accurate even with fewer satellites. GNSS/INS and the LiDAR-based SLAM technique can be effectively integrated to form a sustainable, highly accurate positioning and mapping solution for use in forests without additional hardware costs. In this study, information such as heading angles and velocities extracted from a GNSS/INS is utilized to improve the positioning accuracy of the SLAM solution, and two information-aided SLAM methods are proposed. First, a heading angle-aided SLAM (H-aided SLAM method is proposed that supplies the heading angle from GNSS/INS to SLAM. Field test results show that the horizontal positioning accuracy of an entire trajectory of 800 m is 0.13 m and is significantly improved (by 70% compared to that

  19. Impact of Contrast Media Concentration on Low-Kilovolt Computed Tomography Angiography: A Systematic Preclinical Approach.

    Science.gov (United States)

    Fleischmann, Ulrike; Pietsch, Hubertus; Korporaal, Johannes G; Flohr, Thomas G; Uder, Michael; Jost, Gregor; Lell, Michael M

    2018-05-01

    Low peak kilovoltage (kVp) protocols in computed tomography angiography (CTA) demand a review of contrast media (CM) administration practices. The aim of this study was to systematically evaluate different iodine concentrations of CM in a porcine model. Dynamic 70 kVp CTA was performed on 7 pigs using a third-generation dual-source CT system. Three CM injection protocols (A-C) with an identical total iodine dose and iodine delivery rate (150 mg I/kg, 12 s, 0.75 g I/s) differed in iodine concentration and flow rate (protocol A: 400 mg I/mL, 1.9 mL/s; B: 300 mg I/mL, 2.5 mL/s; C: 150 mg I/mL, 5 mL/s). All protocols were applied in a randomized order and compared intraindividually. Arterial enhancement at different locations in the pulmonary artery, the aorta, and aortic branches was measured over time. Time attenuation curves, peak enhancement, time to peak, and bolus tracking delay times needed for static CTA were calculated. The reproducibility of optimal parameters was tested in single-phase CTA. The heart rates of the pigs were comparable for all protocols (P > 0.7). The injection pressure was significantly higher for protocol A (64 ± 5 psi) and protocol C (55 ± 3 psi) compared with protocol B (39 ± 2 psi) (P < 0.001). Average arterial peak enhancement in the dynamic scans was 359 ± 51 HU (protocol A), 382 ± 36 HU (B), and 382 ± 60 HU (C) (A compared with B and C: P < 0.01; B compared with C: P = 0.995). Time to peak enhancement decreased with increasing injection rate. The delay time for bolus tracking depended on the injection rate as well and was highest for protocol A (4.7 seconds) and lowest for protocol C (3.9 seconds) (P = 0.038). The peak enhancement values of the dynamic scans highly correlated with those of the single-phase CTA scans. In 70 kVp CTA, 300 mg I/mL iodine concentrations showed to be superior to high-concentration CM when keeping the iodine delivery rate constant. Besides, iodine concentrations as low as 150 mg I/mL can be administered

  20. Lower thermospheric nitric oxide concentrations derived from WINDII observations of the green nightglow continuum at 553.1 nm

    Directory of Open Access Journals (Sweden)

    C. H. A. von Savigny

    1999-11-01

    Full Text Available Vertical profiles of nitric oxide in the altitude range 90 to 105 km are derived from 553 nm nightglow continuum measurements made with the Wind Imaging Interferometer (WINDII on the Upper Atmosphere Research Satellite (UARS. The profiles are derived under the assumption that the continuum emission is due entirely to the NO+O air afterglow reaction. Vertical profiles of the atomic oxygen density, which are required to determine the nitric oxide concentrations, are derived from coordinated WINDII measurements of the atomic oxygen OI 557.7 nm nightglow emission. Data coverage for local solar times ranging from 20 h to 04 h, and latitudes ranging from 42°S to 42°N, is achieved by zonally averaging and binning data obtained on 18 nights during a two-month period extending from mid-November 1992 until mid-January 1993. The derived nitric oxide concentrations are significantly smaller than those obtained from rocket measurements of the airglow continuum but they do compare well with model expectations and nitric oxide densities measured using the resonance fluorescence technique on the Solar Mesosphere Explorer satellite. The near-global coverage of the WINDII observations and the similarities to the nitric oxide global morphology established from other satellite measurements strongly suggests that the NO+O reaction is the major source of the continuum near 553 nm and that there is no compelling reason to invoke additional sources of continuum emission in this immediate spectral region.Key words. Atmospheric composition and structure (airglow and aurora; thermosphere – composition and chemistry; instruments and techniques

  1. Modeling of a compliant joint in a Magnetic Levitation System for an endoscopic camera

    NARCIS (Netherlands)

    Simi, M.; Tolou, N.; Valdastri, P.; Herder, J.L.; Menciassi, A.; Dario, P.

    2012-01-01

    A novel compliant Magnetic Levitation System (MLS) for a wired miniature surgical camera robot was designed, modeled and fabricated. The robot is composed of two main parts, head and tail, linked by a compliant beam. The tail module embeds two magnets for anchoring and manual rough translation. The

  2. Design of a magnetic lead screw for wave energy conversion

    DEFF Research Database (Denmark)

    Holm, Rasmus Koldborg; Berg, Nick Ilsoe; Walkusch, Morten

    2013-01-01

    used to compensate for the magnetic attraction forces and the resulting deflection of the rotor. In addition, in order to avoid some of the assembling-related disadvantages of using surface-mounted magnets, an embedded-magnet topology is proposed. To demonstrate the technology, a scaled 17-kN MLS...

  3. Reliability of the Motor Learning Strategy Rating Instrument for Children and Youth with Acquired Brain Injury

    Science.gov (United States)

    Kamath, Trishna; Pfeifer, Megan; Banerjee-Guenette, Priyanka; Hunter, Theresa; Ito, Julia; Salbach, Nancy M.; Wright, Virginia; Levac, Danielle

    2012-01-01

    Purpose: To evaluate reliability and feasibility of the Motor Learning Strategy Rating Instrument (MLSRI) in children with acquired brain injury (ABI). The MLSRI quantifies the extent to which motor learning strategies (MLS) are used within physiotherapy (PT) interventions. Methods: PT sessions conducted by ABI team physiotherapists with a…

  4. Rapid Resuscitation with Small Volume Hypertonic Saline Solution ...

    African Journals Online (AJOL)

    Rapid Resuscitation with Small Volume Hypertonic Saline Solution for Patients in Traumatic Haemorrhagic Shock. ... The data were entered into a computer data base and analysed. Results: Forty five patients were enrolled and resuscitated with 250 mls 7.5% HSS. Among the studied patients, 88.9% recovered from shock ...

  5. Library Science Education: A New Role for Academic Libraries

    Science.gov (United States)

    Wesley, Threasa L.

    2018-01-01

    Many individuals working in library and information organizations do not hold a master of library science (MLS) degree or other specialized library science credential. Recognizing that this professional gap could be addressed by diversified educational opportunities, the W. Frank Steely Library at Northern Kentucky University in Highland Heights…

  6. Monoacyl phosphatidylcholine inhibits the formation of lipid multilamellar structures during in vitro lipolysis of self-emulsifying drug delivery systems.

    Science.gov (United States)

    Tran, Thuy; Siqueira, Scheyla D V S; Amenitsch, Heinz; Rades, Thomas; Müllertz, Anette

    2017-10-15

    The colloidal structures formed during lipolysis of self-emulsifying drug delivery systems (SEDDS) might affect the solubilisation and possibly the absorption of drugs. The aim of the current study is to elucidate the structures formed during the in vitro lipolysis of four SEDDS containing medium-chain glycerides and caprylocaproyl polyoxyl-8 glycerides (Labrasol), with or without monoacyl phosphatidylcholine (MAPC). In situ synchrotron small-angle X-ray scattering (SAXS) was combined with ex situ cryogenic transmission electron microscopy (cryo-TEM) and dynamic light scattering (DLS) to elucidate the generated structures. The SAXS scattering curves obtained during the lipolysis of MAPC-free SEDDS containing 43-60% w/w Labrasol displayed a lamellar phase peak at q=2.13nm -1 that increased with Labrasol concentration, suggesting the presence of multilamellar structures (MLS) with a d-spacing of 2.95nm. However, SEDDS containing 20-30% w/w MAPC did not form MLS during the lipolysis. The cryo-TEM and DLS studies showed that MAPC-free SEDDS formed coarse emulsions while MAPC-containing SEDDS formed nanoemulsions during the dispersion in digestion medium. From the first minute and during the entire lipolysis process, SEDDS both with and without MAPC generated uni-, bi-, and oligo-lamellar vesicles. The lipolysis kinetics in the first minutes of the four SEDDS correlated with an increased intensity of the SAXS curves and the rapid transformation from lipid droplets to vesicles observed by cryo-TEM. In conclusion, the study elucidates the structures formed during in vitro lipolysis of SEDDS and the inhibitory effect of MAPC on the formation of MLS. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Extraction and Simplification of Building Façade Pieces from Mobile Laser Scanner Point Clouds for 3D Street View Services

    Directory of Open Access Journals (Sweden)

    Yan Li

    2016-12-01

    Full Text Available Extraction and analysis of building façades are key processes in the three-dimensional (3D building reconstruction and realistic geometrical modeling of the urban environment, which includes many applications, such as smart city management, autonomous navigation through the urban environment, fly-through rendering, 3D street view, virtual tourism, urban mission planning, etc. This paper proposes a building facade pieces extraction and simplification algorithm based on morphological filtering with point clouds obtained by a mobile laser scanner (MLS. First, this study presents a point cloud projection algorithm with high-accuracy orientation parameters from the position and orientation system (POS of MLS that can convert large volumes of point cloud data to a raster image. Second, this study proposes a feature extraction approach based on morphological filtering with point cloud projection that can obtain building facade features in an image space. Third, this study designs an inverse transformation of point cloud projection to convert building facade features from an image space to a 3D space. A building facade feature with restricted facade plane detection algorithm is implemented to reconstruct façade pieces for street view service. The results of building facade extraction experiments with large volumes of point cloud from MLS show that the proposed approach is suitable for various types of building facade extraction. The geometric accuracy of building façades is 0.66 m in x direction, 0.64 in y direction and 0.55 m in the vertical direction, which is the same level as the space resolution (0.5 m of the point cloud.

  8. Educating Assessors: Preparing Librarians with Micro and Macro Skills

    Directory of Open Access Journals (Sweden)

    Rachel Applegate

    2016-04-01

    Full Text Available Abstract Objective – To examine the fit between libraries’ needs for evaluation skills, and library education and professional development opportunities. Many library position descriptions and many areas of library science education focus on professional skills and activities, such as delivering information literacy, designing programs, and managing resources. Only some positions, some parts of positions, and some areas of education specifically address assessment/evaluation skills. The growth of the Library Assessment Conference, the establishment of the ARL-ASSESS listserv, and other evidence indicates that assessment skills are increasingly important. Method – Four bodies of evidence were examined for the prevalence of assessment needs and assessment education: the American Library Association core competencies; job ads from large public and academic libraries; professional development courses and sessions offered by American Library Association (ALA divisions and state library associations; and course requirements contained in ALA-accredited Masters of Library Science (MLS programs. Results – While one-third of job postings made some mention of evaluation responsibilities, less than 10% of conference or continuing education offerings addressed assessment skills. In addition, management as a topic is a widespread requirement in MLS programs (78%, while research (58% and assessment (15% far less common. Conclusions – Overall, there seems to be more need for assessment/evaluation skills than there are structured offerings to educate people in developing those skills. In addition, roles are changing: some of the most professional-level activities of graduate-degreed librarians involve planning, education, and assessment. MLS students need to understand that these macro skills are essential to leadership, and current librarians need opportunities to add to their skill sets.

  9. Magnetoresistance Probe of Ultrathin Mn5Ge3 Films with Anderson Weak Localization

    International Nuclear Information System (INIS)

    Li-Jun, Chen; De-Yong, Wang; Qing-Feng, Zhan; Wei, He; Qing-An, Li

    2008-01-01

    We present the magnetoresistance measurements of ultrathin Mn 5 Ge 3 films with different thicknesses at low temperatures. Owing to the lattice mismatch between Mn 5 Ge 3 and Ge (111), the thickness of Mn 5 Ge 3 films has a significant effect on the magnetoresistance. When the thickness of Mn is more than 72 monolayers (MLs), the magnetoresistance of the Mn 5 Ge 3 films appears a peak at about 6kOe, which shows that the magnetoresistance results from the Anderson weak localization effect and the variable range hopping in the presence of a magnetic field. The magnetic and semiconducting properties indicate that the Mn 5 Ge 3 film is a potential material for spin injection. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  10. Clinical variability of neuroacanthocytosis syndromes-a series of six patients with long follow-up.

    Science.gov (United States)

    Dulski, J; Sołtan, W; Schinwelski, M; Rudzińska, M; Wójcik-Pędziwiatr, M; Wictor, L; Schön, F; Puschmann, A; Klempíř, J; Tilley, L; Roth, J; Tacik, P; Fujioka, S; Drozdowski, W; Sitek, E J; Wszolek, Z; Sławek, J

    2016-08-01

    To provide clinical clues to differential diagnosis in patients with chorea and other movement disorders with blood acanthocytes. We present a long-term video accompanied follow-up of six Caucasian patients with neuroacanthocytosis from several centers, three diagnosed with chorea-acanthocytosis (ChAc): 34-y.o.(no.1), 36-y.o.(no.2), 43-y.o.(no.3), two diagnosed with McLeod Syndrome (MLS): 52-y.o.(no.4), 61-y.o.(no.5) and one 63-y.o.(no.6), a brother of no.5, with clinical suspicion of MLS. Additionally we report pathological findings of the mother of two brothers with MLS reported in our series with acanthocytes on peripheral blood smear The patients had an unremarkable family history and were asymptomatic until adulthood. Patients no. 1,2,4,5,6 developed generalized chorea and patient no. 3 had predominant bradykinesia. Patients no. 1,2,3 had phonic and motor tics, additionally patients no. 1 and 2 exhibited peculiar oromandibular dystonia with tongue thrusting. In patients no. 2 and 3 dystonic supination of feet was observed, patient no. 3 subsequently developed bilateral foot drop. Patients no. 2 and 4 had signs of muscle atrophy. Tendon reflexes were decreased or absent and electroneurography demonstrated sensorimotor neuropathy in patients no. 1,2,3,4,5, except no. 6. Generalized seizures were seen in patients no. 2,3,5,6 and myoclonic jerks in patient no. 1. Cognitive deterioration was reported in patients no. 1,2,3,5,6. Serum creatine kinase levels were elevated in all six patients. We highlight the variability of clinical presentation of neuroacanthocytosis syndromes and the long time from the onset to diagnosis with the need to screen the blood smears in uncertain cases, however, as in one of our cases acanthocytes may even be not found. Based on our observations and data from the literature we propose several red flags that should raise the suspicion of an NA syndrome in a patient with a movement disorder: severe orofacial dyskinesia with tongue and lip

  11. [Effect of shifting sand burial on evaporation reduction and salt restraint under saline water irrigation in extremely arid region].

    Science.gov (United States)

    Zhang, Jian-Guo; Zhao, Ying; Xu, Xin-Wen; Lei, Jia-Qiang; Li, Sheng-Yu; Wang, Yong-Dong

    2014-05-01

    The Taklimakan Desert Highway Shelterbelt is drip-irrigated with high saline groundwater (2.58-29.70 g x L(-1)), and shifting sand burial and water-salt stress are most common and serious problems in this region. So it is of great importance to study the effect of shifting sand burial on soil moisture evaporation, salt accumulation and their distribution for water saving, salinity restraint, and suitable utilization of local land and water resources. In this study, Micro-Lysimeters (MLS) were used to investigate dynamics of soil moisture and salt under different thicknesses of sand burial (1, 2, 3, 4, and 5 cm), and field control experiments of drip-irrigation were also carried out to investigate soil moisture and salt distribution under different thicknesses of shifting sand burial (5, 10, 15, 20, 25, 30, 35, and 40 cm). The soil daily and cumulative evaporation decreased with the increase of sand burial thickness in MLS, cumulative evaporation decreased by 2.5%-13.7% compared with control. And evaporative inhibiting efficiency increased with sand burial thickness, evaporative inhibiting efficiency of 1-5 cm sand burial was 16.7%-79.0%. Final soil moisture content beneath the interface of sand burial increased with sand burial thickness, and it increased by 2.5%-13.7% than control. The topsoil EC of shifting sand in MLS decreased by 1.19-6.00 mS x cm(-1) with the increasing sand burial thickness, whereas soil salt content beneath the interface in MLS increased and amplitude of the topsoil salt content was higher than that of the subsoil. Under drip-irrigation with saline groundwater, average soil moisture beneath the interface of shifting sand burial increased by 0.4% -2.0% compare with control, and the highest value of EC was 7.77 mS x cm(-1) when the sand burial thickness was 10 cm. The trend of salt accumulation content at shifting sand surface increased firstly, and then decreased with the increasing sand burial thickness. Soil salt contents beneath the

  12. Analysis of CO in the tropical troposphere using Aura satellite data and the GEOS-Chem model: insights into transport characteristics of the GEOS meteorological products

    Directory of Open Access Journals (Sweden)

    Junhua Liu

    2010-12-01

    Full Text Available We use the GEOS-Chem chemistry-transport model (CTM to interpret the spatial and temporal variations of tropical tropospheric CO observed by the Microwave Limb Sounder (MLS and the Tropospheric Emission Spectrometer (TES. In so doing, we diagnose and evaluate transport in the GEOS-4 and GEOS-5 assimilated meteorological fields that drive the model, with a particular focus on vertical mixing at the end of the dry season when convection moves over the source regions. The results indicate that over South America, deep convection in both GEOS-4 and GEOS-5 decays at too low an altitude early in the wet season, and the source of CO from isoprene in the model (MEGAN v2.1 is too large, causing a lag in the model's seasonal maximum of CO compared to MLS CO in the upper troposphere (UT. TES and MLS data reveal problems with excessive transport of CO to the eastern equatorial Pacific and lofting in the ITCZ in August and September, particularly in GEOS-4. Over southern Africa, GEOS-4 and GEOS-5 simulations match the phase of the observed CO variation from the lower troposphere (LT to the UT fairly well, although the magnitude of the seasonal maximum is underestimated considerably due to low emissions in the model. A sensitivity run with increased emissions leads to improved agreement with observed CO in the LT and middle troposphere (MT, but the amplitude of the seasonal variation is too high in the UT in GEOS-4. Difficulty in matching CO in the LT and UT implies there may be overly vigorous vertical mixing in GEOS-4 early in the wet season. Both simulations and observations show a time lag between the peak in fire emissions (July and August and in CO (September and October. We argue that it is caused by the prevailing subsidence in the LT until convection moves south in September, as well as the low sensitivity of TES data in the LT over the African Plateau. The MLS data suggest that too much CO has been transported from fires in northern Africa to the UT

  13. 3D change detection at street level using mobile laser scanning point clouds and terrestrial images

    Science.gov (United States)

    Qin, Rongjun; Gruen, Armin

    2014-04-01

    Automatic change detection and geo-database updating in the urban environment are difficult tasks. There has been much research on detecting changes with satellite and aerial images, but studies have rarely been performed at the street level, which is complex in its 3D geometry. Contemporary geo-databases include 3D street-level objects, which demand frequent data updating. Terrestrial images provides rich texture information for change detection, but the change detection with terrestrial images from different epochs sometimes faces problems with illumination changes, perspective distortions and unreliable 3D geometry caused by the lack of performance of automatic image matchers, while mobile laser scanning (MLS) data acquired from different epochs provides accurate 3D geometry for change detection, but is very expensive for periodical acquisition. This paper proposes a new method for change detection at street level by using combination of MLS point clouds and terrestrial images: the accurate but expensive MLS data acquired from an early epoch serves as the reference, and terrestrial images or photogrammetric images captured from an image-based mobile mapping system (MMS) at a later epoch are used to detect the geometrical changes between different epochs. The method will automatically mark the possible changes in each view, which provides a cost-efficient method for frequent data updating. The methodology is divided into several steps. In the first step, the point clouds are recorded by the MLS system and processed, with data cleaned and classified by semi-automatic means. In the second step, terrestrial images or mobile mapping images at a later epoch are taken and registered to the point cloud, and then point clouds are projected on each image by a weighted window based z-buffering method for view dependent 2D triangulation. In the next step, stereo pairs of the terrestrial images are rectified and re-projected between each other to check the geometrical

  14. 219 ORIGINAL ARTICLE SEROPREVALENCE OF HEPATITIS C ...

    African Journals Online (AJOL)

    boaz

    ABSTRACT. Background: Hepatitis C virus (HCV) infection is a major public health concern. The aim of this study was to ascertain the seroprevalence and risk factors of HCV antibodies among pregnant women in Anyigba, Kogi State North Central Nigeria. Materials and methods:Blood samples (5mls) were collected from ...

  15. Seroprevalence of Hepatitis C Virus (HCV) antibodies in pregnant ...

    African Journals Online (AJOL)

    Background: Hepatitis C virus (HCV) infection is a major public health concern. The aim of this study was to ascertain the seroprevalence and risk factors of HCV antibodies among pregnant women in Anyigba, Kogi State North Central Nigeria. Materials and methods:Blood samples (5mls) were collected from one hundred ...

  16. Reactive airway and anaesthesia

    African Journals Online (AJOL)

    Administrator

    the bevel facing upward. On piercing the interspinous ligament, the stylet was removed and a 20mls resistance-free glass syringe half full of air, attached to the epidural needle. A gentle continuous pressure was applied to the plunger as the needle was. *Correspondence author: Lawal I Ibrahim. Department of Anaesthesia.

  17. Design and test of a novel magnetic lead screw for active suspension system in a vehicle

    DEFF Research Database (Denmark)

    Berg, Nick Ilsø; Holm, Rasmus Koldborg; Rasmussen, Peter Omand

    2014-01-01

    . Furthermore the Magnetic Lead Screw is introduced and its benefits when used with an active suspension system are discussed. Based on a model of a quarter car, the design specifications for the MLS active suspension system are found, which leads to a design study. The design study investigates the relation...

  18. 77 FR 15148 - Order Granting an Application of BF Enterprises, Inc. Under the Securities Exchange Act of 1934

    Science.gov (United States)

    2012-03-14

    ... the benefit of other persons. The Commission explained that this would ``have the effect of.../ts051011mls.html . See also Testimony on Crowdfunding and Capital Formation, by Meredith B. Cross, Director... numerical triggers may not, in all cases, be consistent with its desire to balance the public benefits of...

  19. Design of a magnetic lead screw for wave energy conversion

    DEFF Research Database (Denmark)

    Holm, Rasmus Koldborg; Berg, Nick Ilsø; Rasmussen, Peter Omand

    2012-01-01

    on the bearing supports used to compensate for the magnetic attraction forces and the resulting deflection of the rotor. Also, in order to avoid some of the production related disadvantages of using surface mounted magnets, an embedded magnet topology is proposed. To demonstrate the technology a scaled 17 kN MLS...

  20. Right colon interposition in corrosive esophageal long segment ...

    African Journals Online (AJOL)

    2013-09-20

    Sep 20, 2013 ... adequate nutrition during all the stages of treatment does help. Paying heed to ... and protein estimation with other investigations is done serially. Few days ... muscle was transected, while sternohyoid and superior ... loss of 823.1 ± 428.5 mls. ... Severe dysphagia is a distressful condition for the patient.

  1. Hysterosalpingography: Still relevant in the evaluation of infertility in ...

    African Journals Online (AJOL)

    MJP

    2015-04-18

    Apr 18, 2015 ... Water-soluble contrast media was introduced using a cannula placed in the cervical canal under aseptic conditions.[6,7]. Films were taken with the patient in the supine supine position, antero-posterior projection and oblique views were done when necessary. 15mls of contrast medium were administered ...

  2. Inferring the drivers of discarding practices from observer data to identify appropriate fishery‐specific solutions

    DEFF Research Database (Denmark)

    Catchpole, Tom; Rochet, Marie‐Joëlle; Madsen, Niels

    2012-01-01

    with associated quota that are above the MLS or minimum length landed. The model is applied to data from the full English observer programme and to French, Danish, Greek, and Spanish case study métiers. The proportionate contribution of the different categories is determined, the differences between métiers...

  3. SORCE and Future Satellite Observations of Solar Irradiance

    Science.gov (United States)

    Cahalan, Robert F.; Rottman, G.; Woods, T.; Lawrence, G.; Kopp, G.; Harder, J.; McClintock, W.

    2003-01-01

    With solar activity just passing the maximum of cycle 23, SORCE is beginning a 5 year mission to measure total solar irradiance (TSI) with unprecedented accuracy using phase-sensitive detection, and to measure spectral solar irradiance (SSI) with unprecedented spectral coverage, from 1 to 2000 nm. The new Total Irradiance Monitor (TIM) has 4 active cavity radiometers, any one of which can be used as a fixed-temperature reference against any other that is exposed to the Sun via a shutter that cycles at a rate designed to minimize noise at the shutter frequency. The new Spectral Irradiance Monitor (SIM) is a dual Fery prism spectrometer that can employ either prism as a monochromatic source on the other prism, thus monitoring its transmission during the mission lifetime. Either prism can measure SSI from 200 to 2000 nm, employing the same phase-sensitive electrical substitution strategy as TIM. SORCE also carries dual SOLSTICE instruments to cover the spectral range 100-320 nm, similar to the instruments onboard UARS, and also an XUV Photometer System (XPS) similar to that on TIMED. SSI has now been added to TSI as a requirement of EOS and NPOESS, because different spectral components drive different components of the climate system - UV into upper atmosphere and stratospheric ozone, IR into tropospheric water vapor and clouds, and Visible into the oceans and biosphere. Succeeding satellite missions being planned for 2006 and 2011 will continue to monitor these critical solar variables.

  4. Evaluation of body mass index and plasma lipid profile in Boerboel ...

    African Journals Online (AJOL)

    This study evaluated the body mass index (BMI) and plasma lipid profile in Boerboel dogs. Body weights (BW), height (H) at shoulder and waist circumference (WC) were obtained from fifty-three Boerboels to determine the BMI while, body condition score (BCS) was determined subjectively. Also 5mls of blood was obtained ...

  5. Evidence that diclofenac and celecoxib are thyroid hormone receptor beta antagonists.

    Science.gov (United States)

    Zloh, Mire; Perez-Diaz, Noelia; Tang, Leslie; Patel, Pryank; Mackenzie, Louise S

    2016-02-01

    Long term use of NSAIDs is linked to side effects such as gastric bleeding and myocardial infarction. Use of in silico methods and pharmacology to investigate the potential for NSAIDs diclofenac, celecoxib and naproxen to bind to nuclear receptors. In silico screening predicted that both diclofenac and celecoxib has the potential to bind to a number of different nuclear receptors; docking analysis confirmed a theoretical ability for diclofenac and celecoxib but not naproxen to bind to TRβ. Results from TRβ luciferase reporter assays confirmed that both diclofenac and celecoxib display TRβ antagonistic properties; celecoxib, IC50 3.6 × 10(-6)M, and diclofenac IC50 5.3 × 10(-6)M, comparable to the TRβ antagonist MLS (IC50 3.1 × 10(-6)M). In contrast naproxen, a cardio-sparing NSAID, lacked TRβ antagonist effects. In order to determine the effects of NSAIDs in whole organ in vitro, we used isometric wire myography to measure the changes to Triiodothyronine (T3) induced vasodilation of rat mesenteric arteries. Incubation of arteries in the presence of the TRβ antagonist MLS000389544 (10(-5)M), as well as diclofenac (10(-5)M) and celecoxib (10(-5)M) but not naproxen significantly inhibited T3 induced vasodilation compared to controls. These results highlight the benefits of computational chemistry methods used to retrospectively analyse well known drugs for side effects. Using in silico and in vitro methods we have shown that both celecoxib and diclofenac but not naproxen exhibit off-target TRβ antagonist behaviour, which may be linked to their detrimental side effects. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Pumping of methane by an ionization assisted Zr/Al getter pump

    International Nuclear Information System (INIS)

    Shen, G.L.

    1987-01-01

    The pumping of methane by an ionization assisted Zr/Al getter pump has been investigated. This pump consists of 12 pieces of ring getters. A spiral shape W filament is located within the ring getters. A bias voltage is applied across the filament and the getter itself. The experiments have shown that (1) when the bias voltage is turned off, the pumping speed of the getter pump for methane increases exponentially with the filament temperature; (2) when the filament temperature is held constant, its pumping speed varies directly with the ionization electron current; (3) when the filament temperature is 2063 0 C and the electron current is 57 mA, the pumping speed of the Zr/Al getter pump is 475 ml/s, and the specific speed is 16.8 ml/s cm 2 ; and (4) an activation energy and critical temperature measured for methane molecules decomposition are, respectively, 47.4 kcal/mol and about 1700 0 C. Analysis of the results indicates that methane is pumped by an ionization assisted Zr/Al getter pump not because of the adsorption and the diffusion of methane molecules directly, but because methane molecules are decomposed as C and H 2 through a catalysis of the hot W filament, carbon is adsorbed on the surface of the W filament, and is diffused into the interior of the W lattice. H 2 is immediately absorbed by the Zr/Al getters. Besides, electron impact with CH 4 would result in the additional decomposition and ionization, then the effect of electron bombardment enhances methane pumping by the Zr/Al getters

  7. Assessment of tidal volume and thoracoabdominal motion using volume and flow-oriented incentive spirometers in healthy subjects

    Directory of Open Access Journals (Sweden)

    V.F. Parreira

    2005-07-01

    Full Text Available The objective of the present study was to evaluate incentive spirometers using volume- (Coach and Voldyne and flow-oriented (Triflo II and Respirex devices. Sixteen healthy subjects, 24 ± 4 years, 62 ± 12 kg, were studied. Respiratory variables were obtained by respiratory inductive plethysmography, with subjects in a semi-reclined position (45º. Tidal volume, respiratory frequency, minute ventilation, inspiratory duty cycle, mean inspiratory flow, and thoracoabdominal motion were measured. Statistical analysis was performed with Kolmogorov-Smirnov test, t-test and ANOVA. Comparison between the Coach and Voldyne devices showed that larger values of tidal volume (1035 ± 268 vs 947 ± 268 ml, P = 0.02 and minute ventilation (9.07 ± 3.61 vs 7.49 ± 2.58 l/min, P = 0.01 were reached with Voldyne, whereas no significant differences in respiratory frequency were observed (7.85 ± 1.24 vs 8.57 ± 1.89 bpm. Comparison between flow-oriented devices showed larger values of inspiratory duty cycle and lower mean inspiratory flow with Triflo II (0.35 ± 0.05 vs 0.32 ± 0.05 ml/s, P = 0.00, and 531 ± 137 vs 606 ± 167 ml/s, P = 0.00, respectively. Abdominal motion was larger (P < 0.05 during the use of volume-oriented devices compared to flow-oriented devices (52 ± 11% for Coach and 50 ± 9% for Voldyne; 43 ± 13% for Triflo II and 44 ± 14% for Respirex. We observed that significantly higher tidal volume associated with low respiratory frequency was reached with Voldyne, and that there was a larger abdominal displacement with volume-oriented devices.

  8. Direct-push geochemical profiling for assessment of inorganic chemical heterogeneity in aquifers

    Science.gov (United States)

    Schulmeister, M.K.; Healey, J.M.; Butler, J.J.; McCall, G.W.

    2004-01-01

    Discrete-depth sampling of inorganic groundwater chemistry is essential for a variety of site characterization activities. Although the mobility and rapid sampling capabilities of direct-push techniques have led to their widespread use for evaluating the distribution of organic contaminants, complementary methods for the characterization of spatial variations in geochemical conditions have not been developed. In this study, a direct-push-based approach for high-resolution inorganic chemical profiling was developed at a site where sharp chemical contrasts and iron-reducing conditions had previously been observed. Existing multilevel samplers (MLSs) that span a fining-upward alluvial sequence were used for comparison with the direct-push profiling. Chemical profiles obtained with a conventional direct-push exposed-screen sampler differed from those obtained with an adjacent MLS because of sampler reactivity and mixing with water from previous sampling levels. The sampler was modified by replacing steel sampling components with stainless-steel and heat-treated parts, and adding an adapter that prevents mixing. Profiles obtained with the modified approach were in excellent agreement with those obtained from an adjacent MLS for all constituents and parameters monitored (Cl, NO3, Fe, Mn, DO, ORP, specific conductance and pH). Interpretations of site redox conditions based on field-measured parameters were supported by laboratory analysis of dissolved Fe. The discrete-depth capability of this approach allows inorganic chemical variations to be described at a level of detail that has rarely been possible. When combined with the mobility afforded by direct-push rigs and on-site methods of chemical analysis, the new approach is well suited for a variety of interactive site-characterization endeavors. ?? 2003 Elsevier B.V. All rights reserved.

  9. Ultraviolet radiation modelling from ground-based and satellite measurements on Reunion Island, southern tropics

    Directory of Open Access Journals (Sweden)

    K. Lamy

    2018-01-01

    . Only clear-sky SUR was modelled, so we needed to sort out the clear-sky measurements. We used two methods to detect cloudy conditions: the first was based on an observer's hourly report on the sky cover, while the second was based on applying Long and Ackerman(2000's algorithm to broadband pyranometer data to obtain the cloud fraction and then discriminating clear-sky windows on SUR measurements. Long et al. (2006's algorithm, with the co-located pyranometer data, gave better results for clear-sky filtering than the observer's report. Multiple model inputs were tested to evaluate the model sensitivity to different parameters such as total ozone column, aerosol optical properties, extraterrestrial spectrum or ozone cross section. For total column ozone, we used ground-based measurements from the SAOZ (Système d'Analyse par Observation Zénithale spectrometer and satellite measurements from the OMI and SBUV instruments, while ozone profiles were derived from radio-soundings and the MLS ozone product. Aerosol optical properties came from a local aerosol climatology established using a Cimel photometer. Since the mean difference between various inputs of total ozone column was small, the corresponding response on UVI modelling was also quite small, at about 1 %. The radiative amplification factor of total ozone column on UVI was also compared for observations and the model. Finally, we were able to estimate UVI on Reunion Island with, at best, a mean relative difference of about 0.5 %, compared to clear-sky observations.

  10. Ultraviolet radiation modelling from ground-based and satellite measurements on Reunion Island, southern tropics

    Science.gov (United States)

    Lamy, Kévin; Portafaix, Thierry; Brogniez, Colette; Godin-Beekmann, Sophie; Bencherif, Hassan; Morel, Béatrice; Pazmino, Andrea; Metzger, Jean Marc; Auriol, Frédérique; Deroo, Christine; Duflot, Valentin; Goloub, Philippe; Long, Charles N.

    2018-01-01

    clear-sky SUR was modelled, so we needed to sort out the clear-sky measurements. We used two methods to detect cloudy conditions: the first was based on an observer's hourly report on the sky cover, while the second was based on applying Long and Ackerman (2000)'s algorithm to broadband pyranometer data to obtain the cloud fraction and then discriminating clear-sky windows on SUR measurements. Long et al. (2006)'s algorithm, with the co-located pyranometer data, gave better results for clear-sky filtering than the observer's report. Multiple model inputs were tested to evaluate the model sensitivity to different parameters such as total ozone column, aerosol optical properties, extraterrestrial spectrum or ozone cross section. For total column ozone, we used ground-based measurements from the SAOZ (Système d'Analyse par Observation Zénithale) spectrometer and satellite measurements from the OMI and SBUV instruments, while ozone profiles were derived from radio-soundings and the MLS ozone product. Aerosol optical properties came from a local aerosol climatology established using a Cimel photometer. Since the mean difference between various inputs of total ozone column was small, the corresponding response on UVI modelling was also quite small, at about 1 %. The radiative amplification factor of total ozone column on UVI was also compared for observations and the model. Finally, we were able to estimate UVI on Reunion Island with, at best, a mean relative difference of about 0.5 %, compared to clear-sky observations.

  11. The effect of alpha-interferon on bone marrow megakaryocytes and platelet production rate in essential thrombocythemia

    International Nuclear Information System (INIS)

    Wadenvik, H.; Kutti, J.; Ridell, B.; Revesz, P.; Jacobsson, S.; Magnusson, B.; Westin, J.; Vilen, L.

    1991-01-01

    In 10 patients with previously untreated essential thrombocythemia (ET), by using 111 In-labeled platelets and megakaryocyte morphometry, the relation between platelet production rate and bone marrow megakaryocytes was evaluated before and during alpha-2b-interferon (IFN) therapy. A highly significant decrease in platelet count occurred during IFN therapy; the platelet counts, at baseline and after 2 and 6 months of IFN therapy, were 1,102 +/- 345 x 10(9)/L, 524 +/- 169 x 10(9)/L (P less than .0001), and 476 +/- 139 x 10(9)/L (P less than .0001), respectively. The decrement in platelet count was mainly a result of diminished platelet production rate, which at baseline and after 2 and 6 months of IFN therapy was 89 +/- 30 x 10(10) platelets/d, 53 +/- 18 x 10(10) platelets/d (P = .0033), and 45 +/- 20 x 10(10) platelets/d (P less than .0001), respectively. Also, a slight shortening of platelet mean life-span (MLS) was observed in response to IFN treatment; platelet MLS was 7.96 +/- 0.69 days at baseline and 6.68 +/- 1.30 days (P = .012) after 6 months of IFN therapy. IFN induced a significant decrease in bone marrow megakaryocyte volume; both megakaryocyte nuclear and cytoplasmatic volumes were affected. The mean megakaryocyte volume was 372 +/- 126 x 10(2) pL/microL at baseline and 278 +/- 147 x 10(2) pL/microL (P = .049) after 6 months of IFN therapy. However, the number of megakaryocytes did not show any significant change in response to IFN. It is concluded that alpha-IFN reduces platelet production rate and the peripheral platelet count in ET mainly through an anti-proliferative action on the megakaryocytes and to a considerably lesser degree by a shortening of platelet MLS

  12. The mesolimbic system participates in the naltrexone-induced reversal of sexual exhaustion: opposite effects of intra-VTA naltrexone administration on copulation of sexually experienced and sexually exhausted male rats.

    Science.gov (United States)

    Garduño-Gutiérrez, René; León-Olea, Martha; Rodríguez-Manzo, Gabriela

    2013-11-01

    Male rats allowed to copulate until reaching sexual exhaustion exhibit a long-lasting sexual behavior inhibition (around 72 h) that can be reversed by systemic opioid receptor antagonist administration. Copulation activates the mesolimbic dopaminergic system (MLS) and promotes endogenous opioid release. In addition, endogenous opioids, acting at the ventral tegmental area (VTA), modulate the activity of the MLS. We hypothesized that endogenous opioids participate in the sexual exhaustion phenomenon by interacting with VTA opioid receptors and consequently, its reversal by opioid antagonists could be exerted at those receptors. In this study we determined the effects of intra-VTA infusion of different doses of the non-specific opioid receptor antagonist naltrexone (0.1-1.0 μg/rat) on the already established sexual behavior inhibition of sexually exhausted male rats. To elucidate the possible involvement of VTA δ-opioid receptors in the naltrexone-mediated reversal of sexual exhaustion, the effects of different doses of the selective δ-opioid receptor antagonist, naltrindole (0.03-1.0 μg/rat) were also tested. Results showed that intra-VTA injection of 0.3 μg naltrexone reversed the sexual inhibition of sexually exhausted rats, evidenced by an increased percentage of animals capable of showing two successive ejaculations. Intra-VTA infused naltrindole did not reverse sexual exhaustion at any dose. It is concluded that the MLS is involved in the reversal of sexual exhaustion induced by systemic naltrexone, and that μ-, but not δ-opioid receptors participate in this effect. Intra-VTA naltrexone infusion to sexually experienced male rats had an inhibitory effect on sexual activity. The opposite effects of intra-VTA naltrexone on male rat sexual behavior expression of sexually experienced and sexually exhausted rats is discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Micropropagation of Araucaria excelsa R. Br. var. glauca Carrière from orthotropic stem explants.

    Science.gov (United States)

    Sarmast, Mostafa Khoshhal; Salehi, Hassan; Khosh-Khui, Morteza

    2012-07-01

    The objectives of the present work were in vitro propagation of Araucaria excelsa R. Br. var. glauca Carrière (Norfolk Island pine) with focus on the evaluation of the mean number of shoots per explant (MNS/E) and mean length of shoots per explants (MLS/E) produced by different parts of the orthotropic stem of A. excelsa R. Br. var. glauca in response to plant growth regulators. Norfolk Island pine axillary meristems responded very well to the 2-iso-pentenyl adenine (2iP) and thidiazuron (TDZ) levels. Explants taken from stem upper segments in the media containing 2iP had a higher MNS/E (3.47) and MLS/E (6.27 mm) in comparison to those taken from stem lower segments, which were 0.71 and 0.51 mm, respectively. Using 0.045 μM TDZ in the MS medium not only resulted in 4.60 MNS/E with 7.08 mm MLS/E but proliferated shoots showed a good performance as well. Investigating the best position of stem explant on mother plant as well as the best concentrations of growth regulators were performed which were useful for efficient micropropagation of this plant. Thirty three percent of explants were rooted in the MS medium containing 3 % sucrose, supplemented with 7.5 μM of both NAA and IBA for 2 weeks before transferring to a half strength MS medium without any growth regulator. Plantlets obtained were acclimatized and transferred to the greenhouse with less than 20 % mortality. This procedure considered the first successful report for regeneration and acclimatization of A. excelsa R. Br. var. glauca plantlet through main stem explants.

  14. Where We Stand

    Science.gov (United States)

    1945-08-01

    that no inteligent and undel tading cooperation from any of the ruilif;Ir ;trgem it’ Ihev b1livvcd that hc top militarl nonmatids bad Ito co ni,eptt)n...o r10mls The possibilities of direct radat navigation are -rear, - emtended by die use of sarong, readily identifiable, artificial echoes prov,,ted

  15. plasmodium falciparium parasitemia in pregnancy in relation

    African Journals Online (AJOL)

    Dr Oboro VO

    Teaching Hospital, Osogbo. A total of 30 (13.3%) women carrying the first pregnancy (primigravida), and ... Malaria has been described as a disease of poverty and ... About 90 percent of all deaths attributable to ... The study was carried out in Olorunda Local ... cubital fossae with 70% alcohol and 5mls of blood was drawn ...

  16. EVALUATION OF GROWTH OF SOME FUNGI IN CRUDE OIL ...

    African Journals Online (AJOL)

    The two species of Aspergillus A. niger and flavus used in the study appreciably tolerated the oil though the growth of A. flavus was retarded as the concentration of oil increased. Botrytis cinerea, Curvularia lunata and Colletotrichum sp. could not grow beyond the concentration of 1ml/10mls of oil Potato Dextrose Dextrose ...

  17. COMMUNITY HEALTH & PRIMARY HEALTH CARE

    African Journals Online (AJOL)

    adedamla

    percentage of mortality and morbidity especially in. 1 ... prevalent in communities with poor food hygiene,. 1 ... and 650mls of clean water will constitute 45-70 ... second to India among 11 countries that were .... 15-30. 31-43. 128. 75. 57.4. 33.6. Marital Status. Single. Married. Separated .... women in child bearing age group.

  18. Radiosensitization of mammalian cells by misonidazole and oxygen: DNA damage exposed by Micrococcus luteus enzymes

    International Nuclear Information System (INIS)

    Skov, K.A.; Palcic, B.; Skarsgard, L.D.

    1979-01-01

    When misonidazole is present during irradiation of hypoxic mammalian cells, an enhancement of single-strand breaks (SSB) in DNA is observed. Oxygen also enhances SSB, presumably in a manner similar to that of misonidazole. The dose-modifying factor (DMF) for 15 mM misonidazole was found to be 3.4, compared to an oxygen enhancement ratio (OER) of 3.5. Another class of DNA damage, namely, sites exposed by an extract of Micrococcus luteus, was examined. Radiation-induced M. luteus extract-sensitive sites (MLS) were also found to be enhanced by the presence of misonidazole or molecular oxygen. The DMF for this damage by 15 mM misonidazole was 1.6 while the OER was 2.5. The ratio of MLS to SSB is approximately 1.25 under hypoxia, 0.9 in the presence of oxygen, and 0.6 in the presence of 15 mM misonidazole under hypoxic conditions. Incubation with misonidazole under conditions which are toxic to mammalian cells (37 0 C, hypoxia), and which result in many SSB, produces no detectable lesions sensitive to the M. luteus extract

  19. Controlled release from bilayer-decorated magnetoliposomes via electromagnetic heating.

    Science.gov (United States)

    Chen, Yanjing; Bose, Arijit; Bothun, Geoffrey D

    2010-06-22

    Nanoscale assemblies that can be activated and controlled through external stimuli represent a next stage in multifunctional therapeutics. We report the formation, characterization, and release properties of bilayer-decorated magnetoliposomes (dMLs) that were prepared by embedding small hydrophobic SPIO nanoparticles at different lipid molecule to nanoparticle ratios within dipalmitoylphosphatidylcholine (DPPC) bilayers. The dML structure was examined by cryogenic transmission electron microscopy and differential scanning calorimetry, and release was examined by carboxyfluorescein leakage. Nanoparticle heating using alternating current electromagnetic fields (EMFs) operating at radio frequencies provided selective release of the encapsulated molecule at low nanoparticle concentrations and under physiologically acceptable EMF conditions. Without radio frequency heating, spontaneous leakage from the dMLs decreased with increasing nanoparticle loading, consistent with greater bilayer stability and a decrease in the effective dML surface area due to aggregation. With radio frequency heating, the initial rate and extent of leakage increased significantly as a function of nanoparticle loading and electromagnetic field strength. The mechanism of release is attributed to a combination of bilayer permeabilization and partial dML rupture.

  20. Non-Obstructive Middle Lobe Syndrome: An Unusual Cause of Recurrent Pneumonia in an Elderly Woman

    Directory of Open Access Journals (Sweden)

    João Rua

    2017-11-01

    Full Text Available An 84-year-old woman had five episodes of pneumonia in 4 months. Despite extensive comorbidities and advanced age, her health status was good and the recurrence seemed unjustified. Exhaustive background investigation revealed 14 episodes of right-sided pneumonias during the 3 previous years and an inconclusive investigation with CT of the thorax and bronchofibroscopy, despite some fibrotic and atelectasic alterations in the right middle lobe. A new right-sided x-ray showed a wedge-shaped density extending anteriorly and inferiorly from the hilum, and CT of the thorax revealed aggravated middle lobe abnormalities with thickening of the bronchial wall and segment atelectasis, without any visible airway obstruction. After extensive work-up had excluded other causes of recurrent pneumonia and immunodeficiency, a non-obstructive middle lobe syndrome (MLS was deemed responsible for the repeated episodes of pneumonia. MLS is characterised by chronic hypoventilation and atelectasis of the middle lobe, facilitating secretion accumulation, chronic inflammation and repeated infection. After treatment with bronchodilators and immunostimulants was initiated, the patient experienced no recurrences for several months.