WorldWideScience

Sample records for type implant system

  1. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

    OpenAIRE

    Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung; Jeong, Chang-Mo

    2014-01-01

    PURPOSE This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess ...

  2. Periodontal ligament formation around different types of dental titanium implants. I. The self-tapping screw type implant system

    DEFF Research Database (Denmark)

    Warrer, K; Karring, T; Gotfredsen, K

    1993-01-01

    The aim of this study was to determine if a periodontal ligament can form around self-tapping, screw type titanium dental implants. Implants were inserted in contact with the periodontal ligament of root tips retained in the mandibular jaws of 7 monkeys. In each side of the mandible, 1 premolar......, a periodontal ligament can form on self-tapping, screw type titanium dental implants in areas where a void is present between the surrounding bone and the implant at the time of insertion....... and 2 molars were removed in such a manner that in approximately half the cases, the root tips were retained. Following healing, the experimental areas were examined on radiographs, and sites were selected for the insertion of the implants, so that every second implant would have a close contact...

  3. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

    Science.gov (United States)

    Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung; Jeong, Chang-Mo

    2014-12-01

    This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (Pabutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.

  4. Successful Rehabilitation of Partial Edentulous Maxilla and Mandible with New Type of Implants: Molecular Precision Implants

    Directory of Open Access Journals (Sweden)

    Matteo Danza

    2014-01-01

    Full Text Available The extraction of teeth results in rapid bone resorption both vertically and horizontally in the first month. The loss of alveolar ridge reduces the chance of implant rehabilitation. Atraumatic extraction, implant placement in extraction socket, and an immediate prosthesis have been proposed as alternative therapies to maintain the volume and contours tissue and reduce time and cost of treatment. The immediate load of implants is a universally practiced procedure; nevertheless a successful procedure requires expertise in both the clinical and the reconstructive stages using a solid implant system. Excellent primary stability and high bone-implant contact are only minimal requirements for any type of implant procedure. In this paper we present a case report using a new type of implants. The new type of implants, due to its sophisticated control system of production, provides to the implantologist a safe and reliable implant, with a macromorphology designed to ensure a close contact with the surrounding bone.

  5. Two-stage implant systems.

    Science.gov (United States)

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  6. Precision of fit between implant impression coping and implant replica pairs for three implant systems.

    Science.gov (United States)

    Nicoll, Roxanna J; Sun, Albert; Haney, Stephan; Turkyilmaz, Ilser

    2013-01-01

    The fabrication of an accurately fitting implant-supported fixed prosthesis requires multiple steps, the first of which is assembling the impression coping on the implant. An imprecise fit of the impression coping on the implant will cause errors that will be magnified in subsequent steps of prosthesis fabrication. The purpose of this study was to characterize the 3-dimensional (3D) precision of fit between impression coping and implant replica pairs for 3 implant systems. The selected implant systems represent the 3 main joint types used in implant dentistry: external hexagonal, internal trilobe, and internal conical. Ten impression copings and 10 implant replicas from each of the 3 systems, B (Brånemark System), R (NobelReplace Select), and A (NobelActive) were paired. A standardized aluminum test body was luted to each impression coping, and the corresponding implant replica was embedded in a stone base. A coordinate measuring machine was used to quantify the maximum range of displacement in a vertical direction as a function of the tightening force applied to the guide pin. Maximum angular displacement in a horizontal plane was measured as a function of manual clockwise or counterclockwise rotation. Vertical and rotational positioning was analyzed by using 1-way analysis of variance (ANOVA). The Fisher protected least significant difference (PLSD) multiple comparisons test of the means was applied when the F-test in the ANOVA was significant (α=.05). The mean and standard deviation for change in the vertical positioning of impression copings was 4.3 ±2.1 μm for implant system B, 2.8 ±4.2 μm for implant system R, and 20.6 ±8.8 μm for implant system A. The mean and standard deviation for rotational positioning was 3.21 ±0.98 degrees for system B, 2.58 ±1.03 degrees for system R, and 5.30 ±0.79 degrees for system A. The P-value for vertical positioning between groups A and B and between groups A and R was <.001. No significant differences were found for

  7. Ion implantation control system

    International Nuclear Information System (INIS)

    Gault, R. B.; Keutzer, L. L.

    1985-01-01

    A control system is disclosed for an ion implantation system of the type in which the wafers to be implanted are mounted around the periphery of a disk which rotates and also moves in a radial direction relative to an ion beam to expose successive sections of each wafer to the radiation. The control system senses beam current which passes through one or more apertures in the disk and is collected by a Faraday cup. This current is integrated to obtain a measure of charge which is compared with a calculated value based upon the desired ion dosage and other parameters. The resultant controls the number of incremental steps the rotating disk moves radially to expose the adjacent sections of each wafer. This process is continued usually with two or more traverses until the entire surface of each wafer has been implanted with the proper ion dosage

  8. Mandibular implant-supported overdentures: attachment systems, and number and locations of implants--Part I.

    Science.gov (United States)

    Warreth, Abdulhadi; Alkadhimi, Aslam Fadel; Sultan, Ahmed; Byrne, Caroline; Woods, Edel

    2015-01-01

    The use of dental implants in replacing missing teeth is an integral part of restorative dental treatment. Use of conventional complete dentures is associated with several problems such as lack of denture stability, support and retention. However, when mandibular complete dentures were used with two or more implants, an improvement in the patients' psychological and social well-being could be seen. There is general consensus that removable implant-supported overdentures (RISOs) with two implants should be considered as the first-choice standard of care for an edentulous mandible. This treatment option necessitates the use of attachment systems that connect the complete denture to the implant. Nevertheless, each attachment system has its inherent advantages and disadvantages, which should be considered when choosing a system. The first part of this article provides an overview on options available to restore the mandibular edentulous arch with dental implants. Different types of attachment systems, their features and drawbacks are also reviewed.

  9. The influence of micro and macro-geometry in term of bone-implant interface in two implant systems: an histomorphometrical study.

    Science.gov (United States)

    Rocci, A; Calcaterra, R; DI Girolamo, M; Rocci, M; Rocci, C; Baggi, L

    2015-01-01

    Many factors could affect the osseous healing of implants such as surface topography of biomaterial, the status of the bone/implant site, implant loading conditions, surgical technique and implant design. The aim of this study was to analyze the BIC of 2 different implants systems characterized by different micro and macrogeometry, that were placed in the posterior maxillary and mandibular jaws of humans, clinically unloaded and retrieved for histomorphometric analyses after 12 weeks. The patients were divided in two groups (Group I and II); group I was composed by 4 patients that each received in the posterior areas of mandible one type A implant [GTB-Plan1Health Amaro (UD) Italy] one type B implant (OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). Group II was composed by 3 patients that each received in the posterior areas of jawsbone one type A implant [GTB-Plan1Health Amaro (UD) Italy] one type B implant (OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). After 12 weeks of healing all the implants of both groups were harvested with the peri-implant bone tissues. Osseointegration process was evaluated throughout measurements of BIC. No statistical significance differences were found among the mean percentage of BIC of Group I - type A were 66,51% versus 49,96% in Group I - type B, as well as among the mean percentage of BIC of Group II - type A were 43.7% versus 60.02% in Group II - type B. Our results highlight that the mean percentage of BIC after 12 weeks from the implants placement without functional loading is not influenced by the composition of the implant surface.

  10. Implant Angle Monitor System of MC3-II

    International Nuclear Information System (INIS)

    Sato, Fumiaki; Sano, Makoto; Nakaoka, Hiroaki; Fujii, Yoshito; Kudo, Tetuya; Nakanishi, Makoto; Koike, Masazumi; Fujino, Yasushi

    2008-01-01

    Precise implant angle control is required for the latest generation of ion implanters to meet further shrink semiconductor device requirements. Especially, the highest angle accuracy is required for Halo implant process of Logic devices. The Halo implant angle affects the device performance, because slight differences of beam divergence change the overlap profile towards the extension. Additionally, twist angle accuracy is demanded in case of channeling angle implant. Therefore monitoring beam angles and wafer twist angles is important. A new monitoring system for the MC3-II, SEN Corp.'s single wafer type medium current implanter has been developed. This paper describes the angle control performance and monitoring system of the MC3-II. For the twist angle control, we developed a wafer notch angle monitor. The system monitors the wafer notch image on the platen. And the notch angle variation is calculated by using image processing method. It is also able to adjust the notch angle according to the angle error. For the tilt angle control, we developed a vertical beam profile monitor. The monitor system can detect beam profile of vertical directions with horizontally scanning beam. It also measures beam angles of a tilt direction to a wafer. The system configuration and sample beam data are presented.

  11. Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Erdman, Ruud A M

    2010-01-01

    Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients.......Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients....

  12. Sinking and fit of abutment of locking taper implant system

    Science.gov (United States)

    Moon, Seung-Jin; Kim, Hee-Jung; Son, Mee-Kyoung

    2009-01-01

    STATEMENT OF PROBLEM Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS 10 Bicon® implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS It was evident, that the amount of abutment sinking in Bicon® Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at 0.45 ± 0.09 mm. CONCLUSION Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location. PMID:21165262

  13. Formation of p-type ZnO thin film through co-implantation

    Science.gov (United States)

    Chuang, Yao-Teng; Liou, Jhe-Wei; Woon, Wei-Yen

    2017-01-01

    We present a study on the formation of p-type ZnO thin film through ion implantation. Group V dopants (N, P) with different ionic radii are implanted into chemical vapor deposition grown ZnO thin film on GaN/sapphire substrates prior to thermal activation. It is found that mono-doped ZnO by N+ implantation results in n-type conductivity under thermal activation. Dual-doped ZnO film with a N:P ion implantation dose ratio of 4:1 is found to be p-type under certain thermal activation conditions. Higher p-type activation levels (1019 cm-3) under a wider thermal activation range are found for the N/P dual-doped ZnO film co-implanted by additional oxygen ions. From high resolution x-ray diffraction and x-ray photoelectron spectroscopy it is concluded that the observed p-type conductivities are a result of the promoted formation of PZn-4NO complex defects via the concurrent substitution of nitrogen at oxygen sites and phosphorus at zinc sites. The enhanced solubility and stability of acceptor defects in oxygen co-implanted dual-doped ZnO film are related to the reduction of oxygen vacancy defects at the surface. Our study demonstrates the prospect of the formation of stable p-type ZnO film through co-implantation.

  14. Attachment systems for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Kim, Ha-Young; Lee, Jeong-Yol; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review was to address treatment outcome according to attachment systems for mandibular implant overdentures in terms of implant survival rate, prosthetic maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted using PubMed and hand searching of relevant journals considering inclusion and exclusion criteria. Clinical trial studies on mandibular implant overdentures until August, 2010 were selected if more than one type of overdenture attachment was reported. Twenty four studies from 1098 studies were finally included and the data on implant survival rate, prosthetic maintenance and complications, patient satisfaction were analyzed relative to attachment systems. RESULTS Four studies presented implant survival rates (95.8 - 97.5% for bar, 96.2 - 100% for ball, 91.7% for magnet) according to attachment system. Ten other studies presented an implant survival rate ranging from 93.3% to 100% without respect to the attachment groups. Common prosthetic maintenance and complications were replacement of an assay for magnet attachments, and activation of a matrix or clip for ball or bar attachments. Prosthetic maintenance and complications most commonly occurred in the magnet groups. Conflicting findings were found on the rate of prosthetic maintenance and complications comparing ball and bar attachments. Most studies showed no significant differences in patient satisfaction depending upon attachment systems. CONCLUSION The implant survival rate of mandibular overdentures seemed to be high regardless attachment systems. The prosthetic maintenance and complications may be influenced by attachment systems. However patient satisfaction may be independent of the attachment system. PMID:23236571

  15. Different types of implants for reconstructive breast surgery.

    Science.gov (United States)

    Rocco, Nicola; Rispoli, Corrado; Moja, Lorenzo; Amato, Bruno; Iannone, Loredana; Testa, Serena; Spano, Andrea; Catanuto, Giuseppe; Accurso, Antonello; Nava, Maurizio B

    2016-05-16

    Breast cancer is the most common cancer in women worldwide, and is a leading cause of cancer death among women. Prophylactic or curative mastectomy is often followed by breast reconstruction for which there are several surgical approaches that use breast implants with which surgeons can restore the natural feel, size and shape of the breast. To assess the effects of different types of breast implants on capsular contracture, surgical short- and long-term complications, postoperative satisfaction level and quality of life in women who have undergone reconstructive breast surgery after mastectomy. We searched the Cochrane Breast Cancer Group's Specialised Register on 20 July 2015, MEDLINE (1985 to 20 July 2015), EMBASE (1985 to 20 July 2015) and the Cochrane Central Register of Controlled Trials (CENTRAL; Issue 8, 2015). We also searched the World Health Organization's International Clinical Trials Registry Platform (WHO ICTRP) and ClinicalTrials.gov on 16 July 2015. We included randomised controlled trials (RCTs) and quasi-RCTs that compared different types of breast implants for reconstructive surgery. We considered the following types of intervention: implant envelope surfaces - texturised versus smooth; implant filler material - silicone versus saline, PVP-Hydrogel versus saline; implant shape - anatomical versus round; implant volume - variable versus fixed; brands - different implant manufacturing companies and implant generation (fifth versus previous generations). Two review authors independently assessed methodological quality and extracted data. We used standard Cochrane methodological procedures. The quality of the evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. Five RCTs with 202 participants met the inclusion criteria. The women participants were typically in their 50s, and the majority of them (about 82%) received reconstructive surgery following breast cancer, while the others had

  16. Implant retention systems for implant-retained overdentures.

    Science.gov (United States)

    Laverty, D P; Green, D; Marrison, D; Addy, L; Thomas, M B M

    2017-03-10

    Implant retained overdentures are being increasingly utilised in both general and specialist practice to rehabilitate patients with missing teeth, particularly those that are edentate. This article aims to inform the reader of a variety of retention systems that are available to retain an implant overdenture and to understand how these systems work, their advantages and disadvantages and to outline some of the clinical and treatment planning considerations involved in selecting the most appropriate retention system for patients.

  17. A new system of implant abutment connection: how to improve a two piece implant system sealing.

    Science.gov (United States)

    Grecchi, F; DI Girolamo, M; Cura, F; Candotto, V; Carinci, F

    2017-01-01

    Implant dentistry has become one of the most successful dentistry techniques for replacing missing teeth. The success rate of implant dentistry is above 80%. However, peri-implantitis is a later complication of implant dentistry that if untreated, can lead to implant loss. One of the hypotized causes of peri-implantis is the bacterial leakage at the level of implant-abutment connection. Bacterial leakage is favored to the presence of a micro gap at the implant-abutment interface, allowing microorganisms to penetrate and colonize the inner part of the implant leading to biofilm accumulation and consequently to peri-implantitis development. To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Implants were immerged in a bacterial culture for twenty-four hours and then bacteria amount was measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 9%. The reported results are better to those of previous studies carried out on different implant systems. Until now, none implant-abutment system has been proven to seal the gap between implant and abutment.

  18. Effect of Attachment Type on Implant Strain in Maxillary Implant Overdentures: Comparison of Ball, Locator, and Magnet Attachments. Part 1. Overdenture with Palate.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    Implant overdentures with attachments have been used in clinical practice and the effect of attachments on implant strain has been frequently reported. However, most studies have focused on mandibular overdentures; there are few reports on maxillary overdentures. The purpose of this study was to examine the influence of attachment type on implant strain in maxillary overdentures under various implant configurations. A maxillary edentulous model with implants and experimental overdentures were fabricated. Four strain gauges were attached to each implant, positioned in anterior, premolar, and molar areas. Three types of unsplinted attachments-ball, locator, and magnet-were set on the implants under various implant configurations. A vertical occlusal load of 98 N was applied through the mandibular complete denture, and implant strain was compared using the Kruskal-Wallis test. Ball attachments caused the greatest amount of strain, while magnet attachments caused the least amount under all conditions. For all attachments, two anterior implants caused significantly more strain than four implants (P magnet attachments are recommended to reduce implant stress. Using only two implants, especially two anterior implants, is not recommended regardless of attachment type.

  19. Comparison of implant component fractures in external and internal type: A 12-year retrospective study.

    Science.gov (United States)

    Yi, Yuseung; Koak, Jai-Young; Kim, Seong-Kyun; Lee, Shin-Jae; Heo, Seong-Joo

    2018-04-01

    The aim of this study was to compare the fracture of implant component behavior of external and internal type of implants to suggest directions for successful implant treatment. Data were collected from the clinical records of all patients who received WARANTEC implants at Seoul National University Dental Hospital from February 2002 to January 2014 for 12 years. Total number of implants was 1,289 and an average of 3.2 implants was installed per patient. Information about abutment connection type, implant locations, platform sizes was collected with presence of implant component fractures and their managements. SPSS statistics software (version 24.0, IBM) was used for the statistical analysis. Overall fracture was significantly more frequent in internal type. The most frequently fractured component was abutment in internal type implants, and screw fracture occurred most frequently in external type. Analyzing by fractured components, screw fracture was the most frequent in the maxillary anterior region and the most abutment fracture occurred in the maxillary posterior region and screw fractures occurred more frequently in NP (narrow platform) and abutment fractures occurred more frequently in RP (regular platform). In external type, screw fracture occurred most frequently, especially in the maxillary anterior region, and in internal type, abutment fracture occurred frequently in the posterior region. placement of an external type implant rather than an internal type is recommended for the posterior region where abutment fractures frequently occur.

  20. Quality of life and cochlear implantation in Usher syndrome type I.

    NARCIS (Netherlands)

    Damen, G.W.J.A.; Pennings, R.J.E.; Snik, A.F.M.; Mylanus, E.A.M.

    2006-01-01

    OBJECTIVES: The objectives of this descriptive, retrospective study were to evaluate quality of life, hearing, and vision in patients with Usher syndrome type I with and without cochlear implant. METHODS: Quality of life (QoL) of 14 patients with Usher type I (USH1) with a cochlear implant (CI)

  1. Retention system for implant-supported dentures used by brazilian dentists who work in implant dentistry

    Directory of Open Access Journals (Sweden)

    Saturnino Aparecido Ramalho

    2010-04-01

    Full Text Available Objective: To provide the dentists with support in the choice of the cement or screw type of retention for implant-supported dentures, according to the patient’s problem. Methods: An opinion questionnaire was applied to a sample of 468 participants, all dentists working in the field of Implant Dentistry, of whom 272 (58.1% participated in the 4th International Congress of Osseointegration of APCD, held in São Paulo (SP from 6 to 9 May 2004, 119 (25.4% participated in the 2nd International Congress of Implant Dentistry of Minas Gerais, between 10 and 12 June 2004 and 77 (16.5% were professors and specialization and master students from São Leopoldo Mandic. Results: The results showed that 254 participants opted for the screw-retained system while 214 opted for the cement-retained system. Conclusion: There was a preference for the use of the screw-retained system, and that both cemented and screw-retained systems have advantages and disadvantages, so that the dentist is left to decide and evaluate them in order to indicate and use them with confidence in different clinical cases.

  2. Nitrogen implantation of type 303 stainless steel gears for improved wear and fatigue resistance

    International Nuclear Information System (INIS)

    Kustas, F.M.; Misra, M.S.; Tack, W.T.

    1987-01-01

    Fine-positioning mechanisms are responsible for accurate and reproducible control of aerospace system devices, i.e. filter grading wheels. Low wear and fatigue resistance of mechanism components, such as pinions and gears, can reduce system performance and reliability. Surface modification using ion implantation with nitrogen was used on type 303 stainless steel pinions and gears to increase tribological performance. Wear-life tests of untreated, nitrogen-implanted and nitrogen-implanted-and-annealed gears were performed in a fine-positioning mechanism under controlled environmental conditions. Wear and fatigue resistance were monitored at selected time intervals which were a percentage of the predicted failure life as determined by a numerical stress analysis. Surface analyses including scanning electron microscopy and Auger electron spectroscopy were performed to establish the wear and fatigue mechanisms and the nitrogen concentration-depth distributions respectively. Nitrogen implantation resulted in a significant improvement in both surface wear and fatigue spalling resistance over those of untreated gears. A 40% reduction in surface wear and a 44% reduction in dedendum spalling was observed. In contrast, the nitrogen-implanted-and-annealed gears showed a 46% increase in sliding wear area and an 11% increase in spall density compared with those of untreated gears, indicating that the post-implantation anneal was detrimental to wear and fatigue resistance. (orig.)

  3. Evaluation of mechanical strengths of three types of mini-implants in artificial bones

    Directory of Open Access Journals (Sweden)

    Yu-Chuan Tseng

    2017-02-01

    Full Text Available We investigates the effect of the anchor area on the mechanical strengths of infrazygomatic mini-implants. Thirty mini-implants were divided into three types based on the material and shape: Type A (titanium alloy, 2.0×12 mm, Type B (stainless steel, 2.0×12 mm, and Type C (titanium alloy, 2.0×11 mm.The mini-implants were inserted at 90° and 45° into the artificial bone to a depth of 7 mm, without predrilling. The mechanical strengths [insertion torque (IT, resonance frequency (RF, and removal torque (RT] and the anchor area were measured. We hypothesized that no correlation exists among the mechanical forces of each brand. In the 90° tests, the IT, RF, and RT of Type C (8.5 N cm, 10.2 kHz, and 6.1 N cm, respectively were significantly higher than those of Type A (5.0 N cm, 7.7 kHz, and 4.7 N cm, respectively. In the 45° test, the RFs of Type C (9.2 kHz was significantly higher than those of Type A (7.0 kHz and Type B (6.7 kHz. The anchor area of the mini-implants was in the order of Type C (706 mm2>Type B (648 mm2>Type A (621 mm2. Type C exhibited no significant correlation in intragroup comparisons, and the hypothesis was accepted. In the 90° and 45° tests, Type C exhibited the largest anchor area and the highest mechanical strengths (IT, RF, and RT among the three types of mini-implants. The anchor area plays a crucial role in the mechanical strength of mini-implants.

  4. Evaluation of mechanical strengths of three types of mini-implants in artificial bones.

    Science.gov (United States)

    Tseng, Yu-Chuan; Wu, Ju-Hui; Ting, Chun-Chan; Chen, Hong-Sen; Chen, Chun-Ming

    2017-02-01

    We investigates the effect of the anchor area on the mechanical strengths of infrazygomatic mini-implants. Thirty mini-implants were divided into three types based on the material and shape: Type A (titanium alloy, 2.0×12 mm), Type B (stainless steel, 2.0×12 mm), and Type C (titanium alloy, 2.0×11 mm).The mini-implants were inserted at 90° and 45° into the artificial bone to a depth of 7 mm, without predrilling. The mechanical strengths [insertion torque (IT), resonance frequency (RF), and removal torque (RT)] and the anchor area were measured. We hypothesized that no correlation exists among the mechanical forces of each brand. In the 90° tests, the IT, RF, and RT of Type C (8.5 N cm, 10.2 kHz, and 6.1 N cm, respectively) were significantly higher than those of Type A (5.0 N cm, 7.7 kHz, and 4.7 N cm, respectively). In the 45° test, the RFs of Type C (9.2 kHz) was significantly higher than those of Type A (7.0 kHz) and Type B (6.7 kHz). The anchor area of the mini-implants was in the order of Type C (706 mm 2 )>Type B (648 mm 2 )>Type A (621 mm 2 ). Type C exhibited no significant correlation in intragroup comparisons, and the hypothesis was accepted. In the 90° and 45° tests, Type C exhibited the largest anchor area and the highest mechanical strengths (IT, RF, and RT) among the three types of mini-implants. The anchor area plays a crucial role in the mechanical strength of mini-implants. Copyright © 2016. Published by Elsevier Taiwan.

  5. Temperature rise during removal of fractured components out of the implant body: an in vitro study comparing two ultrasonic devices and five implant types.

    Science.gov (United States)

    Meisberger, Eric W; Bakker, Sjoerd J G; Cune, Marco S

    2015-12-01

    Ultrasonic instrumentation under magnification may facilitate mobilization of screw remnants but may induce heat trauma to surrounding bone. An increase of 5°C is considered detrimental to osseointegration. The objective of this investigation was to examine the rise in temperature of the outer implant body after 30 s of ultrasonic instrumentation to the inner part, in relation to implant type, type of ultrasonic equipment, and the use of coolants in vitro. Two ultrasonic devices (Satelec Suprasson T Max and Electro Medical Systems (EMS) miniMaster) were used on five different implant types that were provided with a thermo couple (Astra 3.5 mm, bone level Regular CrossFit (RC) 4.1 mm, bone level Narrow CrossFit (NC) 3.3 mm, Straumann tissue level regular body regular neck 3.3 mm, and Straumann tissue level wide body regular neck 4.8 mm), either with or without cooling during 30 s. Temperature rise at this point in time is the primary outcome measure. In addition, the mean maximum rise in temperature (all implants combined) was assessed and statistically compared among devices, implant systems, and cooling mode (independent t-tests, ANOVA, and post hoc analysis). The Satelec device without cooling induces the highest temperature change of up to 13°C, particularly in both bone level implants (p < 0.05) but appears safe for approximately 10 s of continuous instrumentation, after which a cooling down period is rational. Cooling is effective for both devices. However, when the Satelec device is used with coolant for a longer period of time, a rise in temperature must be anticipated after cessation of instrumentation, and post-operational cooling is advised. The in vitro setup used in this experiment implies that care should be taken when translating the observations to clinical recommendations, but it is carefully suggested that the EMS device causes limited rise in temperature, even without coolant.

  6. [Cochlear implantation in patients with Waardenburg syndrome type II].

    Science.gov (United States)

    Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian

    2010-05-01

    To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.

  7. Implant Surface Temperature Changes during Er:YAG Laser Irradiation with Different Cooling Systems.

    Directory of Open Access Journals (Sweden)

    Abbas Monzavi

    2014-04-01

    Full Text Available Peri-implantitis is one of the most common reasons for implant failure. Decontamination of infected implant surfaces can be achieved effectively by laser irradiation; although the associated thermal rise may cause irreversible bone damage and lead to implant loss. Temperature increments of over 10ºC during laser application may suffice for irreversible bone damage.The purpose of this study was to evaluate the temperature increment of implant surface during Er:YAG laser irradiation with different cooling systems.Three implants were placed in a resected block of sheep mandible and irradiated with Er:YAG laser with 3 different cooling systems namely water and air spray, air spray alone and no water or air spray. Temperature changes of the implant surface were monitored during laser irradiation with a K-type thermocouple at the apical area of the fixture.In all 3 groups, the maximum temperature rise was lower than 10°C. Temperature changes were significantly different with different cooling systems used (P<0.001.Based on the results, no thermal damage was observed during implant surface decontamination by Er:YAG laser with and without refrigeration. Thus, Er:YAG laser irradiation can be a safe method for treatment of periimplantitis.

  8. Immediate loading of titanium hexed screw-type implants in the edentulous patient: case report.

    Science.gov (United States)

    Calvo, M P; Muller, E; Garg, A K

    2000-01-01

    Histologic and histomorphometric studies in both animals and humans have shown that more rapid and greater bone-to-implant contact can be achieved with implants that incorporate certain surface characteristics compared with the original machined-surface implants. Such findings are significant because various implant designs may allow the fixtures to sufficiently resist functional loading sooner than originally thought. The case report presented here indicates that immediate loading of hexed titanium screw-type implants in the anterior mandible can lead to successful osseointegration and clinical outcome. The number of implants placed, their distribution, and the type of rigid connection are critical considerations for immediate loading. A bone height that can accommodate dental implants > or = 10 mm long is recommended. Biomechanically, the implants to be immediately loaded must be stable and resistant to macromovement to ensure good osseointegration.

  9. CLINICAL CONSIDERATIONS OF DENTAL IMPLANT SYSTEM IN IMMEDIATE LOADING IMPLANT CASES

    Directory of Open Access Journals (Sweden)

    Carolina Damayanti Marpaung

    2015-06-01

    Full Text Available Immediate loading of dental implant has been researched intensively in the development of Branemark’s early concept of 2 stages implant placement. This was embarked from both patients and practiitioner’s convenience towards a simpler protocol and shorter time frame. Many recent researchers later found that micromotions derived from occlusal loading for a certain degree, instead of resulting a fibrous tissue encapsulation, can enhance the osseointegration process. Dental Implant system enhancement towards maximizing the primary stability held a key factor in Branemark’s concept development. Surgical protocol and implant design was found to give a significant contribution to the prognosis of immediate-loading implants.

  10. High surface hole concentration p-type GaN using Mg implantation

    International Nuclear Information System (INIS)

    Long Tao; Yang Zhijian; Zhang Guoyi

    2001-01-01

    Mg ions were implanted on Mg-doped GaN grown by metalorganic chemical vapor deposition (MOCVD). The p-type GaN was achieved with high hole concentration (8.28 x 10 17 cm -3 ) conformed by Van derpauw Hall measurement after annealing at 800 degree C for 1 h. this is the first experimental report of Mg implantation on Mg-doped GaN and achieving p-type GaN with high surface hole concentration

  11. Tissue response to a new type of biomaterial implanted subcutaneously in rats

    DEFF Research Database (Denmark)

    Boennelycke, Marie; Christensen, Lise; Nielsen, Lene Feldskov

    2011-01-01

    -cellular matrix (ECM) or estrogen. Methods Ten implants of each type were tested for 3 and 8 weeks, respectively. Histological assessment of connective tissue organization, inflammation, vascularization, and thickness of regenerated tissue was undertaken. Results All implants had a high degree of biocompatibility....... ECM-enriched implants had significantly higher inflammatory scores compared to pure implants at 3 weeks. At 8 weeks, neither of the parameters differed significantly. No trace of the implants remained. Conclusions The MPEG-PLGA is highly biocompatible, degrades quickly, and seems inert in the process...

  12. High surface hole concentration p-type GaN using Mg implantation

    CERN Document Server

    Long Tao; Zhang Guo Yi

    2001-01-01

    Mg ions were implanted on Mg-doped GaN grown by metalorganic chemical vapor deposition (MOCVD). The p-type GaN was achieved with high hole concentration (8.28 x 10 sup 1 sup 7 cm sup - sup 3) conformed by Van derpauw Hall measurement after annealing at 800 degree C for 1 h. this is the first experimental report of Mg implantation on Mg-doped GaN and achieving p-type GaN with high surface hole concentration

  13. Peri-Implantitis Associated with Type of Cement: A Retrospective Analysis of Different Types of Cement and Their Clinical Correlation to the Peri-Implant Tissue.

    Science.gov (United States)

    Korsch, Michael; Walther, Winfried

    2015-10-01

    The cementation of fixed implant-supported dental restorations involves the risk of leaving excess cement in the mouth which can promote biofilm formation in the peri-implant sulcus. As a result, an inflammation may develop. The aim of the present study was to investigate the clinical effect of two different luting cements on the peri-implant tissue. Within the scope of a retrospective clinical follow-up study, the prosthetic structures of 22 patients with 45 implants were revised. In all cases, a methacrylate cement (Premier Implant Cement [PIC], Premier® Dental Products Company, Plymouth Meeting, PA, USA) had been used for cementation. In 16 additional patients with 28 implants, the suprastructures were retained with a zinc oxide-eugenol cement (Temp Bond [TB], Kerr Sybron Dental Specialities, Glendora, CA, USA). These patients were evaluated in the course of routine treatment. In both populations, the retention time of the suprastructures was similar (TB 3.77 years, PIC 4.07 years). In the PIC cases, 62% of all implants had excess cement. In the TB cases, excess cement was not detectable on any of the implants. Bleeding on probing was significantly more frequent on implants cemented with PIC (100% with and 94% without excess cement) than on implants cemented with TB (46%). Pocket suppuration was observed on 89% of the PIC-cemented implants with excess cement (PIC without excess cement 24%), whereas implants with TB were not affected by it at all. The peri-implant bone loss was significantly greater in the PIC patients (with excess cement 1.37 mm, without excess cement 0.41 mm) than it was in the TB patients (0.07 mm). The frequency of undetected excess cement depends essentially on the type of cement used. Cements that tend to leave more undetected excess have a higher prevalence for peri-implant inflammation and cause a more severe peri-implant bone loss. © 2014 Wiley Periodicals, Inc.

  14. Clinical evaluation of a novel dental implant system as single implants under immediate loading conditions - 4-month post-loading results from a multicentre randomised controlled trial.

    Science.gov (United States)

    Esposito, Marco; Trullenque-Eriksson, Anna; Blasone, Rodolfo; Malaguti, Giuliano; Gaffuri, Cristiano; Caneva, Marco; Minciarelli, Armando; Luongo, Giuseppe

    preference regarding the two implant systems evaluated. Three operators preferred GENESIS implants, two had no preference and one preferred GENESIS in medium and soft bone and PRIMA in hard bone. No statistically significant differences were observed between the systems' implant types, although four GENESIS implants failed versus none of the PRIMA type. Longer follow-ups of wider patient populations are needed to better understand whether there is an effective advantage with one of the two implant designs. Conflict-of-interest statement: This research project was originally funded by Keystone Italia, Dental spa (Verona, Italy), the manufacturer of the implants evaluated in this investigation. 
 
However, when Keystone Italia received the data of the present manuscript, they refused to honour the financial agreement for the present publication. Therefore, no further follow-ups of this trial will be considered. A legal action was initiated against Keystone Italia. The data belonged to the authors and by no means was the manufacturer allowed to interfere with the conduct of the trial or the publication of the results.

  15. Influence of Number of Implants and Attachment Type on Stress Distribution in Mandibular Implant-Retained Overdentures: Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Mohamed I. El-Anwar

    2017-03-01

    CONCLUSION: Caps deformation and stresses are negligible in cases of using locator attachment in comparison to ball attachments. This may indicate longer lifetime and less repair/maintenance operations in implant overdentures retained by locator attachments. Although the study revealed that bone was insensitive to a number of implants or attachment type, it may be recommended to use two implants in the canine region than using four, where the locator attachments were found to be better.

  16. Architecture and control of a high current ion implanter system

    International Nuclear Information System (INIS)

    Bayer, E.H.; Paul, L.F.; Kranik, J.R.

    1979-01-01

    The design of an ion implant system for use in production requires that special attention be given to areas of design which normally are not emphasized on research or development type ion implanters. Manually operated, local controls are replaced by remote controls, automatic sequencing, and digital displays. For ease of maintenance and replication the individual components are designed as simply as possible and are contained in modules of separate identities, joined only by the beam line and electrical interconnections. A production environment also imposes requirements for the control of contamination and maintainability of clean room integrity. For that reason the major portion of the hardware is separated from the clean operator area and is housed in a maintenance core area. The controls of a production system should also be such that relatively unskilled technicians are able to operate the system with optimum repeatability and minimum operator intervention. An extensive interlock system is required. Most important, for use in production the ion implant system has to have a relatively high rate of throughput. Since the rate of throughput at a given dose is a function of beam current, pumpdown time and wafer handling capacity, design of components affecting these parameters has been optimized. Details of the system are given. (U.K.)

  17. Cranial implant design using augmented reality immersive system.

    Science.gov (United States)

    Ai, Zhuming; Evenhouse, Ray; Leigh, Jason; Charbel, Fady; Rasmussen, Mary

    2007-01-01

    Software tools that utilize haptics for sculpting precise fitting cranial implants are utilized in an augmented reality immersive system to create a virtual working environment for the modelers. The virtual environment is designed to mimic the traditional working environment as closely as possible, providing more functionality for the users. The implant design process uses patient CT data of a defective area. This volumetric data is displayed in an implant modeling tele-immersive augmented reality system where the modeler can build a patient specific implant that precisely fits the defect. To mimic the traditional sculpting workspace, the implant modeling augmented reality system includes stereo vision, viewer centered perspective, sense of touch, and collaboration. To achieve optimized performance, this system includes a dual-processor PC, fast volume rendering with three-dimensional texture mapping, the fast haptic rendering algorithm, and a multi-threading architecture. The system replaces the expensive and time consuming traditional sculpting steps such as physical sculpting, mold making, and defect stereolithography. This augmented reality system is part of a comprehensive tele-immersive system that includes a conference-room-sized system for tele-immersive small group consultation and an inexpensive, easily deployable networked desktop virtual reality system for surgical consultation, evaluation and collaboration. This system has been used to design patient-specific cranial implants with precise fit.

  18. Finite Element Analysis of Stress Distribution in Three Commonly Used Implant Systems in D2 and D4 Bone Densities

    Directory of Open Access Journals (Sweden)

    C Radha

    2016-01-01

    Materials and Methods : Pro-engineer 3-0 software was used to create the geometric models of the three implant systems (Nobel biocare, Biohorizon, Adin and two bone densities D2 and D4. Six 3D models were created to simulate each one of the three implant systems supporting a metal ceramic crown placed in two different densities of bone D2 and D4. The Poisson′s ratio(΅ and Youngs modulus(E of elasticity were assigned to different materials used for the models. Vertical and oblique loads of 450N each were applied on all six models. Von Mises stress analysis was done with ANSYS software. Results : Von Mises stresses were more within D4 type bone than D2 type, for all the three systems of implants and less stresses were seen in Biohorizon implant followed by Nobel Biocare and Adin implant particularly in D4 bone. Conclusion: The study concluded that the selection of a particular implant system should be based on the scientific research rather than on popularity.

  19. Remote powering and data communication for implanted biomedical systems

    CERN Document Server

    Kilinc, Enver Gurhan; Maloberti, Franco

    2016-01-01

    This book describes new circuits and systems for implantable biomedical applications and explains the design of a batteryless, remotely-powered implantable micro-system, designed for long-term patient monitoring.  Following new trends in implantable biomedical applications, the authors demonstrate a system which is capable of efficient, remote powering and reliable data communication.  Novel architecture and design methodologies are used to transfer power with a low-power, optimized inductive link and data is transmitted by a reliable communication link.  Additionally, an electro-mechanical solution is presented for tracking and monitoring the implantable system, while the patient is mobile.  ·         Describes practical example of an implantable batteryless biomedical system; ·         Analyzes and compares various energy harvesting and power transfer methods; ·         Describes design of remote powering link and data communication of the implantable system, comparing differe...

  20. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  1. Methods to Improve Osseointegration of Dental Implants in Low Quality (Type-IV Bone: An Overview

    Directory of Open Access Journals (Sweden)

    Hamdan S. Alghamdi

    2018-01-01

    Full Text Available Nowadays, dental implants have become more common treatment for replacing missing teeth and aim to improve chewing efficiency, physical health, and esthetics. The favorable clinical performance of dental implants has been attributed to their firm osseointegration, as introduced by Brånemark in 1965. Although the survival rate of dental implants over a 10-year observation has been reported to be higher than 90% in totally edentulous jaws, the clinical outcome of implant treatment is challenged in compromised (bone conditions, as are frequently present in elderly people. The biomechanical characteristics of bone in aged patients do not offer proper stability to implants, being similar to type-IV bone (Lekholm & Zarb classification, in which a decreased clinical fixation of implants has been clearly demonstrated. However, the search for improved osseointegration has continued forward for the new evolution of modern dental implants. This represents a continuum of developments spanning more than 20 years of research on implant related-factors including surgical techniques, implant design, and surface properties. The methods to enhance osseointegration of dental implants in low quality (type-IV bone are described in a general manner in this review.

  2. Methods to Improve Osseointegration of Dental Implants in Low Quality (Type-IV) Bone: An Overview.

    Science.gov (United States)

    Alghamdi, Hamdan S

    2018-01-13

    Nowadays, dental implants have become more common treatment for replacing missing teeth and aim to improve chewing efficiency, physical health, and esthetics. The favorable clinical performance of dental implants has been attributed to their firm osseointegration, as introduced by Brånemark in 1965. Although the survival rate of dental implants over a 10-year observation has been reported to be higher than 90% in totally edentulous jaws, the clinical outcome of implant treatment is challenged in compromised (bone) conditions, as are frequently present in elderly people. The biomechanical characteristics of bone in aged patients do not offer proper stability to implants, being similar to type-IV bone (Lekholm & Zarb classification), in which a decreased clinical fixation of implants has been clearly demonstrated. However, the search for improved osseointegration has continued forward for the new evolution of modern dental implants. This represents a continuum of developments spanning more than 20 years of research on implant related-factors including surgical techniques, implant design, and surface properties. The methods to enhance osseointegration of dental implants in low quality (type-IV) bone are described in a general manner in this review.

  3. Influence of connection type on the biomechanical behavior of distal extension mandibular removable partial dentures supported by implants and natural teeth.

    Science.gov (United States)

    Xiao, Wei; Li, Zhiyong; Shen, Shiqian; Chen, Shaowu; Chen, Sulin; Wang, Jiawei

    2016-02-01

    Few studies are performed to evaluate the influence of connection type on the stress distribution of distal extension mandibular removable partial dentures (RPDs) supported by both implants and natural teeth. In this study, five three-dimensional finite element models were prepared to simulate mandibular bilateral partially edentulous arches. Four were RPDs supported by both implants and natural teeth, and the other one was RPDs supported only by natural teeth. The maximum equivalent (EQV) stress values of bone around implants, the abutments, and the mucosa displacements of the related supporting structures were measured. It was found that a non-rigid telescopic coping was more favorable to protect the implant than a rigid telescopic coping. Compared with other connection types, the easy resilient attachment (ERA) system seemed to be effective to associate implant without complications. However, the results obtained in the present study should be cautiously interpreted in the clinic.

  4. The effect of provisional restoration type on micromovement of implants.

    Science.gov (United States)

    Holst, Stefan; Geiselhoeringer, Hans; Wichmann, Manfred; Holst, Alexandra Ioana

    2008-09-01

    The osseointegration or fibrous encapsulation of immediately loaded dental implants depends largely on the extent of implant micromovement. The impact of acrylic resin or metal-reinforced acrylic resin provisional restorations on this movement is currently unknown. The purpose of this study was to isolate and measure the effect of provisional restoration type on the vertical displacement of adjacent implants under load at 2 locations. Vertical loads ranging from 10-200 N were applied to polymethyl methacrylate resin (n=56) or metal-reinforced acrylic resin provisional restorations (n=56) supported by 4 implants inserted into homogenous artificial bone in a "u-shaped" alignment. Provisional restorations were first loaded in the anterior segment where the provisional restoration was supported by a mesial and distal implant, followed by loading on an extension 8 mm distal to the last implant. Vertical displacement of the 2 implants nearest the load application was measured and recorded using an optical image correlation technique based on photogrammetric principles. Data were subjected to a nonparametric multivariate analysis (generalized Wilcoxon test) and a Mann-Whitney test with a 2-tailed P value (alpha=.05). There was no significant difference in the vertical implant displacement of the 2 provisional restoration groups when they were loaded in the anterior segment. However, when loads were applied to the distal cantilever, metal reinforcement resulted in less vertical displacement of the next-to-last implant. The mean vertical displacement of the next-to-last implant when supporting an acrylic resin provisional restoration increased from 20 microm +/-3 microm (pooled loads of 10-50 N) to 130 microm +/-21 microm (pooled loads of 160-200 N), while the vertical displacement of the implant when retaining a metal-reinforced acrylic resin provisional restoration increased from 10 microm +/-2 microm to 69 microm +/-13 microm under the same loads (Pprovisional

  5. Cone-morse implant connection system significantly reduces bacterial leakage between implant and abutment: an in vitro study.

    Science.gov (United States)

    Baj, A; Bolzoni, A; Russillo, A; Lauritano, D; Palmieri, A; Cura, F; Silvestre, F J; Giannì, A B

    2017-01-01

    Osseointegrated implants are very popular dental treatments today in the world. In osseointegrated implants, the occlusal forces are transmitted from prosthesis through an abutment to a dental implant. The abutment is connected to the implant by mean of a screw. A screw is the most used mean for connecting an implant to an abutment. Frequently the screws break and are lost. There is an alternative to screw retained abutment systems: the cone-morse connection (CMC). The CMC, thanks to the absence of the abutment screw, guarantees no micro-gaps, no micro-movements, and a reduction of bacterial leakage between implant and abutment. As P. gingivalis and T. forsythia penetration might have clinical relevance, it was the purpose of this investigation to evaluate molecular leakage of these two bacteria in a new CMC implants systems (Leone Spa®, Florence, Italy). To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Four cone-morse Leone implants (Leone® Spa, Florence, Italy) were immerged in a bacterial culture for 24 h and bacteria amount was then measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 3% for P. gingivalis and 4% for T. forsythia. Cone-morse connection implant system has very low bacterial leakage percentage and is similar to one-piece implants.

  6. Effect of Attachment Type on Denture Strain in Maxillary Implant Overdentures: Part 1. Overdenture with Palate.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    This study examined the effects of attachments on strain in maxillary implant overdentures supported by two or four implants. A maxillary edentulous model with implants inserted into anterior, premolar, and molar areas was fabricated, and three types of unsplinted attachments-ball, locator, and magnet-were set on the implants distributed under various conditions. Maxillary experimental dentures were fabricated, and two strain gauges were attached at the anterior midline on the labial and palatal sides. A vertical occlusal load of 98 N was applied and shear strain of the dentures was measured. On both sides, magnet attachments resulted in the lowest shear strain, while ball attachments resulted in the highest shear strain under most conditions. However, differences in shear strain among the three attachment types were not significant when supported by four implants, especially molar implants. Shear strain of the maxillary implant overdenture was lowest when using magnet attachments. Magnet attachments mounted on four implants are recommended to prevent denture complications when using maxillary implant overdentures.

  7. P- and N-type implantation doping of GaN with Ca and O

    International Nuclear Information System (INIS)

    Zolper, J.C.; Wilson, R.G.; Pearton, S.J.

    1996-01-01

    III-N photonic devices have made great advances in recent years following the demonstration of doping of GaN p-type with Mg and n-type with Si. However, the deep ionization energy level of Mg in GaN (∼ 160 meV) limits the ionized of acceptors at room temperature to less than 1.0% of the substitutional Mg. With this in mind, the authors used ion implantation to characterize the ionization level of Ca in GaN since Ca had been suggested by Strite to be a shallow acceptor in GaN. Ca-implanted GaN converted from n-to-p type after a 1,100 C activation anneal. Variable temperature Hall measurements give an ionization level at 169 meV. Although this level is equivalent to that of Mg, Ca-implantation may have advantages (shallower projected range and less straggle for a given energy) than Mg for electronic devices. In particular, the authors report the first GaN device using ion implantation doping. This is a GaN junction field effect transistor (JFET) which employed Ca-implantation. A 1.7 microm JFET had a transconductance of 7 mS/mm, a saturation current at 0 V gate bias of 33 mA/mm, a f t of 2.7 GHz, and a f max of 9.4 GHz. O-implantation was also studied and shown to create a shallow donor level (∼ 25 meV) that is similar to Si. SIMS profiles of as-implanted and annealed samples showed no measurable redistribution of either Ca or O in GaN at 1,125 C

  8. Laboratory implantation for well type ionization chambers calibration

    International Nuclear Information System (INIS)

    Vianello, E.A.; Dias, D.J.; Almeida, C.E. de

    1998-01-01

    The Radiological Science Laboratory is implanting a service for calibration of well type chambers by IAEA training program. The kerma rate in the air (mu Gy/h) of the linear Cs-137 reference source CDCS-J4 have been determined using a well type chamber Standard Imaging HDR-1000 model, which have been calibrated at Secondary Standard Laboratory Calibration of IAEA, whereas two HDR-1000 Plus chambers were calibrated too, following the same standards. The results were compared with Wisconsin University calibration certification and has demonstrated that well type ionization chamber calibration can be used in brachytherapy for several kinds of radionuclides. (Author)

  9. Image-guided navigation system for placing dental implants.

    Science.gov (United States)

    Casap, Nardy; Wexler, Alon; Lustmann, Joshua

    2004-10-01

    Navigation-guided surgery has recently been introduced into various surgical disciplines, including oral and maxillofacial surgery. Since the advent of dental implants, dental computed tomography (CT) scans have been used as a diagnostic tool for preoperative planning, but not as part of the surgical phase. This article explains the principles of computer-assisted surgery and describes the use of a computer-guided navigation system in dental implantology. The system uses preoperative dental CT scans for planning and as an integral part of the surgical procedure. This system allows continuous intraoperative coordination of the implantation phase with the preoperative plan, optimizing the accuracy of implant surgery. Deviations from the planned location of the implants are minimal. Several cases are discussed.

  10. Early loading of plalatal implants (ortho-type II a prospective multicenter randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Gedrange Tomasz

    2007-09-01

    Full Text Available Abstract Background In orthodontic treatment, anchorage control is a fundamental aspect. Usually conventional mechanism for orthodontic anchorage control can be either extraoral or intraoral that is headgear or intermaxillary elastics. Their use are combined with various side effects such as tipping of occlusal plane or undesirable movements of teeth. Especially in cases, where key-teeth are missing, conventional anchorage defined as tooth-borne anchorage will meet limitations. Therefore, the use of endosseous implants for anchorage purposes are increasingly used to achieve positional stability and maximum anchorage. Methods/Design The intended study is designed as a prospective, multicenter randomized controlled trial (RCT, comparing and contrasting the effect of early loading of palatal implant therapy versus implant loading after 12 weeks post implantation using the new ortho-implant type II anchor system device (Orthosystem Straumann, Basel, Switzerland. 124 participants, mainly adult males or females, whose diagnoses require temporary stationary implant-based anchorage treatment will be randomized 1:1 to one of two treatment groups: group 1 will receive a loading of implant standard therapy after a healing period of 12 week (gold standard, whereas group 2 will receive an early loading of orthodontic implants within 1 week after implant insertion. Participants will be at least followed for 12 months after implant placement. The primary endpoint is to investigate the behavior of early loaded palatal implants in order to find out if shorter healing periods might be justified to accelerate active orthodontic treatment. Secondary outcomes will focus e.g. on achievement of orthodontic treatment goals and quantity of direct implant-bone interface of removed bone specimens. As tertiary objective, a histologic and microtomography evaluation of all retrieved implants will be performed to obtain data on the performance of the SLA surface in human bone

  11. Influence of the implant abutment types and the dynamic loading on initial screw loosening

    Science.gov (United States)

    Kim, Eun-Sook

    2013-01-01

    PURPOSE This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at 30° to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for 105 cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (α=0.05). RESULTS Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION The abutment types did not have a significant influence on short term screw loosening. On the other hand, after 105 cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not. PMID:23509006

  12. Influence of the implant abutment types and the dynamic loading on initial screw loosening

    OpenAIRE

    Kim, Eun-Sook; Shin, Soo-Yeon

    2013-01-01

    PURPOSE This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at ...

  13. Patient satisfaction with maxillary 3-implant overdentures using different attachment systems opposing mandibular 2-implant overdentures.

    Science.gov (United States)

    Al-Zubeidi, Mohammed I; Alsabeeha, Nabeel H M; Thomson, W Murray; Payne, Alan G T

    2012-05-01

    Patient-based outcomes with maxillary overdentures on a minimum number of implants, opposing mandibular 2-implant overdentures are not evident in the literature. To evaluate patient's satisfaction with maxillary 3-implant overdentures, opposing mandibular 2-implant overdentures, using two different attachment systems over the first 2 years of service. Forty participants wearing mandibular 2-implant overdentures for 3 years were randomly allocated to one of two similar implant system groups to receive maxillary 3-implant overdentures. Twenty participants were allocated to splinted and unsplinted attachment system treatment groups for each system. Patient satisfaction with pre-treatment complete maxillary dentures, with maxillary 3-implant overdentures at baseline and annually for 2 years, was measured using visual analogue scale questionnaires and the oral health impact profiles. Palatal coverage of the maxillary overdentures was reduced at the first annual recall. Data showed significant improvement in pain reduction, comfort, stability, and function variables of the visual analogue scale after treatment. Analysis by prosthodontic design using visual analogue scale showed no significant difference. The total oral health impact profile-14 scores after treatment for all participants, regardless of prosthodontic design, were significantly lower (more satisfied). The overall oral health impact profile-20E score at baseline was significantly higher (more satisfied) compared with pre-treatment conventional maxillary dentures. No significant changes were observed in the first or second years compared with baseline results. Twenty-two participants (84.6%) preferred reduced palatal coverage, regardless of prosthodontic design, after 1 year. Twenty participants (76.9%) still preferred reduced palatal coverage at the end of the second year. The provision of maxillary 3-implant overdentures to oppose mandibular 2-implant overdentures significantly improve levels of patient

  14. Intra-arterial port implantation for intra-arterial chemotherapy : comparison between PIPS(Percutaneously Implantable Port System) and port system

    International Nuclear Information System (INIS)

    Yoon, Sang Jin; Shim, Hyung Jin; Jung, Hun Young; Choi, Yong Ho; Kim, Yang Soo; Song, In Sup; Kwak, Byung Kook

    1999-01-01

    To compare the techniques and complications of intra-arterial port implantation for intra-arterial chemotherapy between PIPS and the port system. For intra-arterial port implantation, 27 cases in 27 patients were retrospectively evaluated using PIPS(PIPS-200, William Cook Europe, Denmark) while for 21 cases in 19 patients a pediatric venous port system(Port-A-Cath, 5.8F, SIMS Deltec, U. S. A.) was used. All intra-arterial port implantation was performed percuteneously in an angiographic ward. Hepatocellular carcinoma was diagnosed in 18 patients and hepatic metastasis in 16. Peripheral cholangiocarcinoma, and pancreatic gastric, ovarian, renal cell and colon carcinoma were included. We compared the techniques and complications between PIPS and the port system. The follow up period ranged from 23 to 494(mean, 163) days in PIPS and from 12 to 431(mean, 150) days in the port system. In all cases, intra-arterial port implantations were technically successful. Port catheter tips were located in the common hepatic artery(n=8), proper hepatic artery(n=7), right hepatic artery(n=5), gastroduodenal artery(n=2), left hepatic artery(n=1), pancreaticoduodenal artery(n=1), inferior mesenteric artery(n=1), lumbar artery(n=1), and renal artery(n=1) in PIPS, and in the proper hepatic artery(n=6), gastroduodenal artery(n=6), common hepatic artery(n=3), right hepatic artery(n=4), inferior mesenteric artery(n=1), and internal iliac artery(n=1) in the port system. Port chambers were buried in infrainguinal subcutaneous tissue. Using PIPS, complications developed in seven cases(25.9%) and of these, four (57.1%) were catheter or chamber related. In the port system, catheter or chamber related complications developed in four cases(19.0%). Because PIPS and the port system have relative merits and demetrits, successful intra-arterial port implantation is possible if equipment is properly selected

  15. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  16. Placement of fin type dental implant in three different surgical situations of alveolar bone

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2007-03-01

    Full Text Available Three different dental implant placements according to surgical implant bed situations were observed in its bone integration 3 months after dental implant insertion. This observation was done on implant system which has plateau or fin system. Elf implants were placed in the upper jaw in two patients. In case one, two implants were inserted immediately after tooth extraction, and the other six implants were placed in the alveolar crest regions in delayed implantation or in which the teeth had been extracted over 6 months of period. In case two, three implants were inserted in the post trauma region in the anterior maxilla, which the labial plate had been lost and reconstructed with bone grafting procedure using a mixture of alloplastic and autogenous bones. The alveolar reconstruction was needed to be performed due to only thin alveolar crest width was left intact. All of those implants observed showed in good integration.

  17. Systemic alendronate treatment improves fixation of press-fit implants: a canine study using nonloaded implants

    DEFF Research Database (Denmark)

    Jensen, Thomas B; Bechtold, Joan E; Chen, Xinqian

    2007-01-01

    of alendronate treatment. Bone ongrowth (bone in contact with implant surface) was estimated using the linear intercept technique and shear strength was calculated as the slope on a load-displacement curve. For the press fit implants, alendronate treatment significantly increased bone ongrowth from 24% to 29...... early implant stability is an important predictor of longevity, systemic alendronate treatment could be an important clinical tool to positively influence the early stages of implant incorporation. Udgivelsesdato: 2007-Jun...

  18. Wireless energizing system for an automated implantable sensor

    Energy Technology Data Exchange (ETDEWEB)

    Swain, Biswaranjan; Nayak, Praveen P.; Kar, Durga P.; Bhuyan, Satyanarayan; Mishra, Laxmi P. [Department of Electronics and Instrumentation Engineering, Siksha ‘O’ Anusandhan University, Bhubaneswar 751030 (India)

    2016-07-15

    The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonant frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.

  19. Wireless energizing system for an automated implantable sensor

    International Nuclear Information System (INIS)

    Swain, Biswaranjan; Nayak, Praveen P.; Kar, Durga P.; Bhuyan, Satyanarayan; Mishra, Laxmi P.

    2016-01-01

    The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonant frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.

  20. Wireless energizing system for an automated implantable sensor.

    Science.gov (United States)

    Swain, Biswaranjan; Nayak, Praveen P; Kar, Durga P; Bhuyan, Satyanarayan; Mishra, Laxmi P

    2016-07-01

    The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonant frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.

  1. Comparison of dual-time-constant and fast-acting automatic gain control (AGC) systems in cochlear implants.

    Science.gov (United States)

    Boyle, Patrick J; Büchner, Andreas; Stone, Michael A; Lenarz, Thomas; Moore, Brian C J

    2009-04-01

    Cochlear implants usually employ an automatic gain control (AGC) system as a first stage of processing. AGC1 was a fast-acting (syllabic) compressor. AGC2 was a dual-time-constant system; it usually performed as a slow-acting compressor, but incorporated an additional fast-acting system to provide protection from sudden increases in sound level. Six experienced cochlear-implant users were tested in a counterbalanced order, receiving one-month of experience with a given AGC type before switching to the other type. Performance was evaluated shortly after provision of a given AGC type and after one-month of experience with that AGC type. Questionnaires, mainly relating to listening in quiet situations, did not reveal significant differences between the two AGC types. However, fixed-level and roving-level tests of sentence identification in noise both revealed significantly better performance for AGC2. It is suggested that the poorer performance for AGC1 occurred because AGC1 introduced cross-modulation between the target speech and background noise, which made perceptual separation of the target and background more difficult.

  2. A Qualitative Study on Patients' Perceptions of Two Types of Attachments for Implant Overdentures.

    Science.gov (United States)

    Pisani, Marina; Bedos, Christophe; da Silva, Cláudia Helena Lovato; Fromentin, Olivier; de Albuquerque, Rubens F

    2017-12-01

    The aim of this qualitative study was to gain a deeper understanding of patient perceptions of wearing implant-retained overdentures with ball-shaped or cylindrical attachment systems. Twenty-two wearers of implant-supported overdentures participated in this qualitative study based on a randomized crossover clinical trial that aimed to compare a cylindrical attachment and a ball attachment. In phase I of the study, group A experienced ball attachments (n = 11) and group B Locator attachments (n = 11) for 1 year. Afterward, in phase II, the attachments were changed; group A received Locator attachments and group B received ball attachments. One week after the attachment's replacement, semistructured individual interviews were conducted. All interviews were audiotaped and transcribed. The analysis was guided by thematic content analysis. Most of the patients from both groups preferred the attachment they received in phase II, regardless the type. A major theme raised by the participants to justify their preference between the attachment types was prosthesis retention/stability, sometimes considered as a positive and other times as a negative factor. Other themes were also explored: oral function, pain, hygiene, previous experiences, confidence on the dentist's work, and esthetic. Aspects related to the retention/stability of the overdentures are the main concerns associated with the perceptions of most patients treated with implant overdentures regardless of the type of attachment. Adequate retention level should be identified and adjusted on an individual basis and maintained overtime as possible. Therefore, follow-up appointments should be planned for readjustment of the attachment's retention. Overretention should be avoided.

  3. The Biolink Implantable Telemetry System

    Science.gov (United States)

    Betancourt-Zamora, Rafael J.

    1999-01-01

    Most biotelemetry applications deal with the moderated data rates of biological signals. Few people have studied the problem of transcutaneous data transmission at the rates required by NASA's Life Sciences-Advanced BioTelemetry System (LS-ABTS). Implanted telemetry eliminate the problems associated with wire breaking the skin, and permits experiments with awake and unrestrained subjects. Our goal is to build a low-power 174-216MHz Radio Frequency (RF) transmitter suitable for short range biosensor and implantable use. The BioLink Implantable Telemetry System (BITS) is composed of three major units: an Analog Data Module (ADM), a Telemetry Transmitter Module (TTM), and a Command Receiver Module (CRM). BioLink incorporates novel low-power techniques to implement a monolithic digital RF transmitter operating at 100kbps, using quadrature phase shift keying (QPSK) modulation in the 174-216MHz ISM band. As the ADM will be specific for each application, we focused on solving the problems associated with a monolithic implementation of the TTM and CRM, and this is the emphasis of this report. A system architecture based on a Frequency-Locked Loop (FLL) Frequency Synthesizer is presented, and a novel differential frequency that eliminates the need for a frequency divider is also shown. A self sizing phase modulation scheme suitable for low power implementation was also developed. A full system-level simulation of the FLL was performed and loop filter parameters were determined. The implantable antenna has been designed, simulated and constructed. An implant package compatible with the ABTS requirements is also being proposed. Extensive work performed at 200MHz in 0.5um complementary metal oxide semiconductors (CMOS) showed the feasibility of integrating the RF transmitter circuits in a single chip. The Hajimiri phase noise model was used to optimize the Voltage Controlled Oscillator (VCO) for minimum power consumption. Two test chips were fabricated in a 0.5pm, 3V CMOS

  4. A case of improved hearing with cochlear implantation in Gaucher disease type 1.

    Science.gov (United States)

    Endo, Shiori; Mizuta, Kunihiro; Yamatodani, Takashi; Nakanishi, Hiroshi; Hosokawa, Kumiko; Misawa, Kiyoshi; Hosokawa, Seiji; Mineta, Hiroyuki

    2018-06-01

    Gaucher disease is a lysosomal storage disorder that is caused by congenital defective function of the enzyme glucocerebrosidase. Glucocerebroside that is not hydrolyzed by glucocerebrosidase mainly accumulates in the reticular tissue. We describe a Japanese boy with Gaucher disease type 1 who developed bilateral profound sensorineural hearing loss within approximately 4years. We performed cochlear implantation initially on his right ear and again on his left ear 5 months later. The cochlear implants were successfully utilized with a speech discrimination score of 95% on a Japanese sentence recognition test. There are many reports of central hearing loss in Gaucher disease type 2 or 3. However, to the best of our knowledge, this is the first report of profound inner ear hearing loss with Gaucher disease. It also appears to be the first record of cochlear implantation for Gaucher disease. Cochlear implants may be useful for sensorineural hearing loss in patients with Gaucher disease without neurological symptoms other than hearing loss. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Vestibular Function After Cochlear Implantation: A Comparison of Three Types of Electrodes.

    Science.gov (United States)

    Frodlund, Jonas; Harder, Henrik; Mäki-Torkko, Elina; Ledin, Torbjörn

    2016-12-01

    To investigate the vestibular function after cochlear implantation with different types of electrode arrays. Retrospective cohort study. Academic tertiary referral center. Forty three adults underwent first cochlear implantation. Three consecutive series of patients: Group 1 (n = 13) implanted with a precurved electrode, Group 2 (n = 15) implanted with a straight electrode, Group 3 (n = 15) implanted with a flexible electrode. Patient's vestibular functions were assessed with pre- and postoperative caloric testing using videonystagmography (VNG). The postoperative reduction of the maximum slow phase velocity (MSPV) in the implanted ear was evaluated. Medical charts were reviewed to evaluate the occurrence of late onset of postoperative vestibular symptoms. Mean reduction of MSPV was 7.6/s (standard deviation [SD] 8.0) in Group 1, 23.1/s (SD 16.6) in Group 2, and 0.1/s (SD 18.5) in Group 3. Significant difference was found between Group 1 and 2 (p < 0.030) and between Group 2 and 3 (p < 0.001). Group 2 showed a higher prevalence of late onset of clinical vertigo (28.6%) than Group 1 (7.7%) and 3 (6.7%). In this prospective study, significantly larger reductions of caloric responses were found in subjects implanted with a straight electrode compared with subjects implanted with a precurved or flexible electrode. These findings seem to correlate to a higher prevalence of postoperative vertigo.

  6. Speech recognition and communication outcomes with cochlear implantation in Usher syndrome type 3.

    Science.gov (United States)

    Pietola, Laura; Aarnisalo, Antti A; Abdel-Rahman, Akram; Västinsalo, Hanna; Isosomppi, Juha; Löppönen, Heikki; Kentala, Erna; Johansson, Reijo; Valtonen, Hannu; Vasama, Juha-Pekka; Sankila, Eeva-Marja; Jero, Jussi

    2012-01-01

    Usher syndrome Type 3 (USH3) is an autosomal recessive disorder characterized by variable type and degree of progressive sensorineural hearing loss and retinitis pigmentosa. Cochlear implants are widely used among these patients. To evaluate the results and benefits of cochlear implantation in patients with USH3. A nationwide multicenter retrospective review. During the years 1995-2005, in 5 Finnish university hospitals, 19 patients with USH3 received a cochlear implant. Saliva samples were collected to verify the USH3 genotype. Patients answered to 3 questionnaires: Glasgow Benefit Inventory, Glasgow Health Status Inventory, and a self-made questionnaire. Audiological data were collected from patient records. All the patients with USH3 in the study were homozygous for the Finnish major mutation (p.Y176X). Either they had severe sensorineural hearing loss or they were profoundly deaf. The mean preoperative hearing level (pure-tone average, 0.5-4 kHz) was 110 ± 8 dB hearing loss (HL) and the mean aided hearing level was 58 ± 11 dB HL. The postoperative hearing level (34 ± 9 dB HL) and word recognition scores were significantly better than before surgery. According to the Glasgow Benefit Inventory scores and Glasgow Health Status Inventory data related to hearing, the cochlear implantation was beneficial to patients with USH3. Cochlear implantation is beneficial to patients with USH3, and patients learn to use the implant without assistance.

  7. Intervention for replacing missing teeth: Different types of implants - evidence summary of updated Cochrane review

    Directory of Open Access Journals (Sweden)

    Balendra Pratap Singh

    2015-01-01

    Full Text Available Around 1300 different types of dental implants are available worldwide and the implant manufacturers are resorting to aggressive marketing strategies; claiming their implants to provide a superior outcome. The clinician is left with a constant dilemma on which implant to choose for better clinical outcome and welfare of the patient. Moreover, in India, economical consideration is a concern too. The dentist has to select an implant that provides a good result and is economical. Cochrane systematic reviews provide the gold standard evidence for intervention, diagnosis, etc., and follow a strict quality control. A Cochrane systematic review was done to shed light on whether the different implant surface modifications, shapes or materials significantly influence clinical outcomes. All randomized controlled trials (RCTs till January 17, 2014 were searched and out of the 81 trials, only 27 met the inclusion criteria. This evidence summary from the review concludes that based on the available literature; there is no evidence of any one type of implant being superior to another. There is weak evidence showing roughened dental implants are more prone to bone loss due to periimplantitis. This review indicated that there is a need for well-designed RCTs, with long-term follow-up and low bias. Moreover, none of the included studies was from India, which also points out the need for improving the quality of RCTs conducted in India.

  8. Systemic Assessment of Patients Undergoing Dental Implant ...

    African Journals Online (AJOL)

    Background: Procedure‑related and patient‑related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty‑one patients were included in the study, in which a total of 110 dental ...

  9. Analytical and experimental position stability of the abutment in different dental implant systems with a conical implant?abutment connection

    OpenAIRE

    Semper-Hogg, Wiebke; Kraft, Silvan; Stiller, Sebastian; Mehrhof, Juergen; Nelson, Katja

    2012-01-01

    Objectives Position stability of the abutment should be investigated in four implant systems with a conical implant?abutment connection. Materials and methods Previously developed formulas and an established experimental setup were used to determine the position stability of the abutment in the four implant systems with a conical implant?abutment connection and different positional index designs: The theoretical rotational freedom was calculated by using the dimensions of one randomly selecte...

  10. Patient satisfaction and dissatisfaction with mandibular two-implant overdentures using different attachment systems: 5-year outcomes.

    Science.gov (United States)

    Al-Zubeidi, Mohammed I; Alsabeeha, Nabeel H M; Thomson, W Murray; Payne, Alan G T

    2012-10-01

    Different attachment systems for mandibular two-implant overdentures could influence levels of patient satisfaction. Positive consensus of the majority of patients being satisfied does not preclude the possibility of dissatisfaction for some. To evaluate patient satisfaction and dissatisfaction before and after 5 years of wearing mandibular two implant overdentures using different attachment systems ; to determine the prognostic relevance of pretreatment complete denture complaints to treatment outcomes. A total of 106 edentulous participants enrolled in a clinical trial completed a preliminary self-report inventory of their original complete denture complaints.New complete maxillary dentures and mandibular two-implant overdentures were provided to each participant using one of six different attachment systems. Patient satisfaction was determined at pretreatment; at baseline with mandibular two-implant overdenture insertion; and then annually for 5 years, using visual analogue and Likert-type scales. Patient satisfaction with mandibular two-implant overdentures showed significant changes pre- to posttreatment(baseline) in all domains, but these were significant immediately and maintained without further significance for 5 years, other than pain with the overdenture. After 5 years, no significant differences were observed with all the attachment systems. Highly significant differences were found with some social and psychological aspects by the fifth year compared to baseline. Diagnostic and prognostic indicators from a pretreatment inventory identified 12 participants (13.5%) who were dissatisfied. These indicators revealed a maladaptive predisposition to mandibular two-implant overdentures. The provision of mandibular two-implant overdentures will, in the majority of patients, significantly enhance levels of patient satisfaction for 5 years, as compared to complete mandibular dentures, regardless of the attachment system. Careful evaluation of pretreatment

  11. Effect of Abutment Modification and Cement Type on Retention of Cement-Retained Implant Supported Crowns

    OpenAIRE

    Farzin, Mitra; Torabi, Kianoosh; Ahangari, Ahmad Hasan; Derafshi, Reza

    2014-01-01

    Objective: Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.The purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations. Materials and Method: Two prefabricated abutments were attached to their corresponding analogs and embedded in an ac...

  12. Laser-Modified Surface Enhances Osseointegration and Biomechanical Anchorage of Commercially Pure Titanium Implants for Bone-Anchored Hearing Systems

    Science.gov (United States)

    Omar, Omar; Simonsson, Hanna; Palmquist, Anders; Thomsen, Peter

    2016-01-01

    Osseointegrated implants inserted in the temporal bone are a vital component of bone-anchored hearing systems (BAHS). Despite low implant failure levels, early loading protocols and simplified procedures necessitate the application of implants which promote bone formation, bone bonding and biomechanical stability. Here, screw-shaped, commercially pure titanium implants were selectively laser ablated within the thread valley using an Nd:YAG laser to produce a microtopography with a superimposed nanotexture and a thickened surface oxide layer. State-of-the-art machined implants served as controls. After eight weeks’ implantation in rabbit tibiae, resonance frequency analysis (RFA) values increased from insertion to retrieval for both implant types, while removal torque (RTQ) measurements showed 153% higher biomechanical anchorage of the laser-modified implants. Comparably high bone area (BA) and bone-implant contact (BIC) were recorded for both implant types but with distinctly different failure patterns following biomechanical testing. Fracture lines appeared within the bone ~30–50 μm from the laser-modified surface, while separation occurred at the bone-implant interface for the machined surface. Strong correlations were found between RTQ and BIC and between RFA at retrieval and BA. In the endosteal threads, where all the bone had formed de novo, the extracellular matrix composition, the mineralised bone area and osteocyte densities were comparable for the two types of implant. Using resin cast etching, osteocyte canaliculi were observed directly approaching the laser-modified implant surface. Transmission electron microscopy showed canaliculi in close proximity to the laser-modified surface, in addition to a highly ordered arrangement of collagen fibrils aligned parallel to the implant surface contour. It is concluded that the physico-chemical surface properties of laser-modified surfaces (thicker oxide, micro- and nanoscale texture) promote bone bonding

  13. Influence of titanium implant surface characteristics on bone regeneration in dehiscence-type defects: an experimental study in dogs.

    Science.gov (United States)

    Schwarz, Frank; Sager, Martin; Kadelka, Ines; Ferrari, Daniel; Becker, Jürgen

    2010-05-01

    The aim of the present study was to compare bone regeneration in dehiscence-type defects at titanium implants with chemically modified sandblasted/acid-etched (modSLA) or dual acid-etched surfaces with a calcium phosphate nanometre particle modification (DCD/CaP). Buccal dehiscence-type defects were surgically created following implant site preparation in both the upper and the lower jaws of 12 fox hounds. Both types of implants were randomly allocated in a split-mouth design and left to heal in a submerged position for 2 and 8 weeks. Dissected blocks were processed for histomorphometrical analysis [e.g. new bone height (NBH), percentage of bone-to-implant contact (BIC), area of new bone fill (BF), and area of mineralized tissue (MT) within BF]. At 2 and 8 weeks, both groups revealed comparable mean BF (2.3+/-0.6 to 2.5+/-0.6 mm(2)versus 2.0+/-0.6 to 1.4+/-0.5 mm(2)) and MT (31.1+/-14.3-83.2+/-8.2%versus 38.9+/-15.9-84.4+/-6.3%) values. However, modSLA implants revealed significantly higher mean NBH (2.4+/-0.8 to 3.6+/-0.3 mm versus 0.9+/-0.8 to 1.8+/-1.4 mm) and BIC (53.3+/-11.3-79.5+/-6.6%versus 19.3+/-16.4-47.2+/-30.7%) values than DCD/CaP implants. ModSLA implants may have a higher potential to support osseointegration in dehiscence-type defects than DCD/CaP implants.

  14. Implantable power generation system utilizing muscle contractions excited by electrical stimulation.

    Science.gov (United States)

    Sahara, Genta; Hijikata, Wataru; Tomioka, Kota; Shinshi, Tadahiko

    2016-06-01

    An implantable power generation system driven by muscle contractions for supplying power to active implantable medical devices, such as pacemakers and neurostimulators, is proposed. In this system, a muscle is intentionally contracted by an electrical stimulation in accordance with the demands of the active implantable medical device for electrical power. The proposed system, which comprises a small electromagnetic induction generator, electrodes with an electrical circuit for stimulation and a transmission device to convert the linear motion of the muscle contractions into rotational motion for the magneto rotor, generates electrical energy. In an ex vivo demonstration using the gastrocnemius muscle of a toad, which was 28 mm in length and weighed 1.3 g, the electrical energy generated by the prototype exceeded the energy consumed for electrical stimulation, with the net power being 111 µW. It was demonstrated that the proposed implantable power generation system has the potential to replace implantable batteries for active implantable medical devices. © IMechE 2016.

  15. Sistema de fabrico rápido de implantes ortopédicos Rapid manufacturing system of orthopedics implants

    Directory of Open Access Journals (Sweden)

    Carlos Relvas

    2009-06-01

    /CAM system. After sterilization, the implant is able to be placed on the patient. The concept was developed using low cost technology and commercially available. The system has been tested in an in vivo hip arthroplasty performed on a sheep. The time increase of surgery was 80 minutes being 40 minutes the time of implant manufacturing. The system developed has been tested and the goals defined of the study achieved enabling the rapid manufacture of an implant in a time period compatible with the surgery time.

  16. Predictors of visual outcomes following Boston type 1 keratoprosthesis implantation.

    Science.gov (United States)

    Ahmad, Sumayya; Akpek, Esen K; Gehlbach, Peter L; Dunlap, Karen; Ramulu, Pradeep Y

    2015-04-01

    To identify predictors of visual outcomes following Boston type 1 Keratoprosthesis (KPro) implantation. Retrospective chart review. Data regarding preoperative clinical and demographic characteristics and postoperative course were collected. Fifty-nine eyes of 59 adult patients who underwent KPro implantation between January 2006 and March 2012 at a single tertiary care center. Preoperative factors associated with all-cause and glaucoma-related loss of visual acuity from the best postoperative visual acuity noted. Fifty-two of 59 eyes (88%) achieved improved vision post implantation, with 7 eyes failing to gain vision as a result of pre-existing glaucoma (n = 4) or retino-choroidal disease (n = 3). Twenty-one eyes (21/52, 40%) maintained their best-ever visual acuity at last visit (mean follow-up period was 37.8 months). The likelihood of maintaining best-ever vision was 71% at 1 year, 59% at 2 years, and 48% at 3 years. Primary KPro implantation was associated with a higher likelihood of losing best-ever vision as compared to KPro implantation as a repeat corneal procedure (hazard ratio [HR] = 3.06; P = 006). The main reasons for postimplantation vision loss was glaucoma (12/31, 39%), and the risk of glaucomatous visual acuity loss was 15% at 2 years and 27% at 3 years. Prior trabeculectomy was associated with a higher rate of vision loss from glaucoma (HR = 3.25, P = .04). Glaucoma is the primary reason for loss of visual acuity after KPro implantation. Conditions necessitating primary KPro surgery are associated with more frequent all-cause vision loss. Prospective trials are necessary to better determine which clinical features best predict KPro success. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Retention systems for extraoral maxillofacial prosthetic implants: a critical review.

    Science.gov (United States)

    Cobein, M V; Coto, N P; Crivello Junior, O; Lemos, J B D; Vieira, L M; Pimentel, M L; Byrne, H J; Dias, R B

    2017-10-01

    We describe the techniques available for retention of implant-supported prostheses: bar-clips, O-rings, and magnets. We present reported preferences and, although this is limited by the heterogeneity of methods used and patients studied, we hope we have identified the best retention systems for maxillofacial prosthetic implants. If practitioners know the advantages and disadvantages of each system, they can choose the most natural and comfortable prosthesis. We searched the PubMed and Scopus databases, and restricted our search to papers published 2001-13. MeSH terms used were Maxillofacial prosthesis and Craniofacial prosthesis OR Craniofacial prostheses. We found a total of 2630 papers, and after duplicates had been removed we analysed the rest and found 25 papers for review. Of these, 12 were excluded because they were case reports or non-systematic reviews. Of the remaining 13, 10 described group analyses and seemed appropriate to find practitioner's choices, as cited in the abstract (n=1611 prostheses). Three papers did not mention the type of prosthetic connection used, so were excluded. The most popular choices for different conditions were analysed, though the sites and retention systems were not specified in all 10 papers. The bar-clip system was the most used in auricular (6/10 papers) and nasal prostheses (4/10). For the orbital region, 6/10 favoured magnets. Non-osseointegrated mechanical or adhesive retention techniques are the least expensive and have no contraindications. When osseointegrated implants are possible, each facial region has a favoured system. The choice of system is influenced by two factors: standard practice and the abilities of the maxillofacial surgeon and maxillofacial prosthetist. Copyright © 2017 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad

    2013-12-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  19. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad; Ouda, Mahmoud H.; Marnat, Loic; Shamim, Atif; Salama, Khaled N.

    2013-01-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  20. [Comparative evaluation of two kinds of micro-implant system with different size].

    Science.gov (United States)

    Wang, Zhen-Dong; Li, Qing-Yi; Wang, Lin; Gu, Yong-Jia

    2009-04-01

    To offer some reference for micro-implant's development and population by analyzing clinical application of two kinds of micro-implant systems. 38 patients treated with MIA (micro-implant anchorage) and 28 patients treated with SDIA (self-driven titanium implant for orthodontic anchorage) were included. Analyzing the rate of lost implants, the gum's reactivity and the efficiency of moving teeth summarized the excellences and shortcomings of two systems. 1) Six of MIA implants fell off after being inserted. Seven of SDIA implants lost when they had been implanted for a month. But they were stable after being inserted again. 2) The gum around 12 SDIA implants got inflammation symptom, but the gum around MIA implants was normal. 3) Both MIA implants and SDIA implants could move teeth effectively and persistently when they were stable. When we apply micro-implant in clinic, we should prevent it from closing roots of teeth and choose the small tip micro-implant. The embedded position should be in area of attachment gum. At the same time, the areas around the tip of micro-implant should be keeping clean.

  1. Retention system for implant-supported dentures used by brazilian dentists who work in implant dentistry

    OpenAIRE

    Saturnino Aparecido Ramalho; Fábio Pontes Dantas

    2010-01-01

    Objective: To provide the dentists with support in the choice of the cement or screw type of retention for implant-supported dentures, according to the patient’s problem. Methods: An opinion questionnaire was applied to a sample of 468 participants, all dentists working in the field of Implant Dentistry, of whom 272 (58.1%) participated in the 4th International Congress of Osseointegration of APCD, held in São Paulo (SP) from 6 to 9 May 2004, 119 (25.4%) participated in the 2nd International ...

  2. Survival of dental implants placed in sites of previously failed implants.

    Science.gov (United States)

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. The effects of N+ implantation on the wear and friction of type 304 and 15-5 PH stainless steels

    International Nuclear Information System (INIS)

    Yost, F.G.; Picraux, S.T.; Follstaedt, D.M.; Pope, L.E.; Knapp, J.A.

    1983-01-01

    Ion implantation of N + into mechanically polished type 304 and 15-5 PH stainless steels was studied to determine its effect on dry wear and friction behavior. Implantation of 4.0 X 10 17 N + cm -2 at 50 keV yielded a depth profile with a peak concentration of about 45 at.% at a depth of 70 nm which dropped to about 10 at.% at 120 nm. Wear and friction were studied in an unlubricated pin-on-disc configuration using type 304 and 440C stainless steel pins. Both N + -implanted steels exhibited reduced wear at low loads but no significant reduction in the coefficient of friction was found. At the lowest normal load studied (12.3 gf), the average maximum wear depth of the implanted 15-5 PH stainless steel disc (about 0.1 μm) was reduced to approximately 10% of that for the corresponding unimplanted pin-on-disc pair after 1000 cycles. At normal loads of 50 gf or above (corresponding to hertzian stresses of 1160 MPa or higher) all beneficial effects were gone. Vacuum heat treatment at 923 K for 1.8 ks of an identically implanted type 304 stainless steel specimen eradicated the beneficial effects of the nitrogen implantation. The N + -implanted discs show similar reductions in wear to discs implanted with titanium and carbon, but the N + -implanted discs do not exhibit the reductions in the coefficient of friction seen with the discs implanted with titanium and carbon. (Auth.)

  4. Clinical application of single-tooth replacement with ankylos implant system

    International Nuclear Information System (INIS)

    Yang Xu; Liu Xue; Zhang Heng; Deng Yan; Guo Zhaozhong; Zhang Yufeng

    2011-01-01

    Objective: To evaluate the clinical effects of Ankylos implant system to restore the loss of single-tooth. Methods: 90 cases with loss of single-tooth were selected and treated with routinely two-stage surgery. When the patients presented with deficient alveolar ridge, guided bone regeneration (GBR), osteotome sinus floor elevation, lateral antrostomy surgery with simultaneous placement of implant were applied. They were restored with platinum ceramic crown. All the implants were followed up, and the records were kept about stability of the implant and abutment, the status of surrounding soft tissue, sealability of implant abutment junction and the marginal bone lossing through X-ray checking,and satisfaction of the patients to mastication and aspect of the restorations. The follow-up time was 1-2.5 years. Results: Among the cases,one case had peri-implant inflammation, and one case had porcelain dropped. No loosening occurred in the other implants and abuments. Implant abutment junction was sealed well. The marginal bone loss 1 year after final restoration was less than 1 mm. Soft tissue surrounding implants was healthy. The satisfaction rate was 98.9% (89/90). According to standard of implant success, 88 cases were successful, the 2.5-year cumulative success rate was 97.8%, 2 cases failed, and the failure rate was 2.2 %. Conclusion: A satisfactory treatment effects could be gotten by using Ankylos implant system to restore the loss of single-tooth. (authors)

  5. Three-Dimensional Finite Element Analysis on Stress Distribution of Internal Implant-Abutment Engagement Features.

    Science.gov (United States)

    Cho, Sung-Yong; Huh, Yun-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    To investigate the stress distribution in an implant-abutment complex with a preloaded abutment screw by comparing implant-abutment engagement features using three-dimensional finite element analysis (FEA). For FEA modeling, two implants-one with a single (S) engagement system and the other with a double (D) engagement system-were placed in the human mandibular molar region. Two types of abutments (hexagonal, conical) were connected to the implants. Different implant models (a single implant, two parallel implants, and mesial and tilted distal implants with 1-mm bone loss) were assumed. A static axial force and a 45-degree oblique force of 200 N were applied as the sum of vectors to the top of the prosthetic occlusal surface with a preload of 30 Ncm in the abutment screw. The von Mises stresses at the implant-abutment and abutment-screw interfaces were measured. In the single implant model, the S-conical abutment type exhibited broader stress distribution than the S-hexagonal abutment. In the double engagement system, the stress concentration was high in the lower contact area of the implant-abutment engagement. In the tilted implant model, the stress concentration point was different from that in the parallel implant model because of the difference in the bone level. The double engagement system demonstrated a high stress concentration at the lower contact area of the implant-abutment interface. To decrease the stress concentration, the type of engagement features of the implant-abutment connection should be carefully considered.

  6. Implant experience with an implantable hemodynamic monitor for the management of symptomatic heart failure.

    Science.gov (United States)

    Steinhaus, David; Reynolds, Dwight W; Gadler, Fredrik; Kay, G Neal; Hess, Mike F; Bennett, Tom

    2005-08-01

    Management of congestive heart failure is a serious public health problem. The use of implantable hemodynamic monitors (IHMs) may assist in this management by providing continuous ambulatory filling pressure status for optimal volume management. The Chronicle system includes an implanted monitor, a pressure sensor lead with passive fixation, an external pressure reference (EPR), and data retrieval and viewing components. The tip of the lead is placed near the right ventricular outflow tract to minimize risk of sensor tissue encapsulation. Implant technique and lead placement is similar to that of a permanent pacemaker. After the system had been successfully implanted in 148 patients, the type and frequency of implant-related adverse events were similar to a single-chamber pacemaker implant. R-wave amplitude was 15.2 +/- 6.7 mV and the pressure waveform signal was acceptable in all but two patients in whom presence of artifacts required lead repositioning. Implant procedure time was not influenced by experience, remaining constant throughout the study. Based on this evaluation, permanent placement of an IHM in symptomatic heart failure patients is technically feasible. Further investigation is warranted to evaluate the use of the continuous hemodynamic data in management of heart failure patients.

  7. P-type single-crystalline ZnO films obtained by (Na,N) dual implantation through dynamic annealing process

    Science.gov (United States)

    Zhang, Zhiyuan; Huang, Jingyun; Chen, Shanshan; Pan, Xinhua; Chen, Lingxiang; Ye, Zhizhen

    2018-02-01

    Single-crystalline ZnO films were grown by plasma-assisted molecular beam epitaxy technique on c-plane sapphire substrates. The films have been implanted with fixed fluence of 130 keV Na and 90 keV N ions at 460 °C. It is observed that dually-implanted single crystalline ZnO films exhibit p-type characteristics with hole concentration in the range of 1.24 × 1016-1.34 × 1017 cm-3, hole mobilities between 0.65 and 8.37 cm2 V-1 s-1, and resistivities in the range of 53.3-80.7 Ω cm by Hall-effect measurements. There are no other secondary phase appearing, with (0 0 2) (c-plane) orientation after ion implantation as identified by the X-ray diffraction pattern. It is obtained that Na and N ions were successfully implanted and activated as acceptors measured by XPS and SIMS results. Also compared to other similar studies, lower amount of Na and N ions make p-type characteristics excellent as others deposited by traditional techniques. It is concluded that Na and N ion implantation and dynamic annealing are essential in forming p-type single-crystalline ZnO films.

  8. A Clinical Retrospective Study of Distal Extension Removable Partial Denture with Implant Surveyed Bridge or Stud Type Attachment

    Science.gov (United States)

    Bae, Eun-Bin; Kim, Seong-Jong; Choi, Jae-Won; Jeon, Young-Chan; Jeong, Chang-Mo; Yun, Mi-Jung; Lee, So-Hyoun

    2017-01-01

    This study was performed to make comparative analysis of the clinical findings between the two different types of the implant-assisted removable partial dentures: removable partial dentures using implant surveyed bridge as an abutment (ISBRPD) and overdenture type of removable partial denture using implant attachment (IARPD). Implant cumulative survival rate, marginal bone resorption, probing depth, peri-implant inflammation, bleeding, plaque, calculus, and complications were evaluated on 24 patients who were treated with implants in conjunction with removable partial denture and have used them for at least 1 year (ISCRPD: n = 12; IARPD: n = 12). There was no failed implant and all implants were functioning without clinical mobility. Marginal bone loss of ISCRPD (1.44 ± 0.57 mm) was significantly lower than that of IARPD (p 0.05), while the calculus was significantly more observed in ISCRPD group than in IARPD group (p < 0.05). The retention loss of IARPD was the most common complication. Within the limits of the present study, it was found that well-planned ISBRPD was clinically appropriate. Longitudinal and systematic clinical studies are necessary to confirm these results. PMID:28497062

  9. A Clinical Retrospective Study of Distal Extension Removable Partial Denture with Implant Surveyed Bridge or Stud Type Attachment

    Directory of Open Access Journals (Sweden)

    Eun-Bin Bae

    2017-01-01

    Full Text Available This study was performed to make comparative analysis of the clinical findings between the two different types of the implant-assisted removable partial dentures: removable partial dentures using implant surveyed bridge as an abutment (ISBRPD and overdenture type of removable partial denture using implant attachment (IARPD. Implant cumulative survival rate, marginal bone resorption, probing depth, peri-implant inflammation, bleeding, plaque, calculus, and complications were evaluated on 24 patients who were treated with implants in conjunction with removable partial denture and have used them for at least 1 year (ISCRPD: n=12; IARPD: n=12. There was no failed implant and all implants were functioning without clinical mobility. Marginal bone loss of ISCRPD (1.44 ± 0.57 mm was significantly lower than that of IARPD (p0.05, while the calculus was significantly more observed in ISCRPD group than in IARPD group (p<0.05. The retention loss of IARPD was the most common complication. Within the limits of the present study, it was found that well-planned ISBRPD was clinically appropriate. Longitudinal and systematic clinical studies are necessary to confirm these results.

  10. Revisiting the stability of mini-implants used for orthodontic anchorage

    Directory of Open Access Journals (Sweden)

    Chung-Chen Jane Yao

    2015-11-01

    Conclusion: This study revealed that once the dental surgeon becomes familiar with the procedure, the stability of orthodontic mini-implants depends on the type of mini-implant, age of the patient, implantation site, and the healing time of the mini-implant. Miniplates are a more feasible anchorage system when miniscrews fail repeatedly.

  11. Retrospective study investigating the clinical success of two provisional implant systems

    OpenAIRE

    Hotz, Nadine

    2011-01-01

    The use of dental implants allows a reliable stabilisation of prosthesis. Usually, definitive implants can´t be used for fixation of prosthesis during their healing period. Therefore, in many cases it is not possible to follow the demand of patients of an immediate loading of definitive implants to avoid a unfixed dental prosthesis. This is one domain of provisional dental implants. The present study of two provisional implant systems approves the benefit of provisional implants during...

  12. Systemic Assessment of Patients Undergoing Dental Implant Surgeries: A Trans- and Post-operative Analysis.

    Science.gov (United States)

    Byakodi, Sanjay; Kumar, Sachin; Reddy, Rajesh Kumar; Kumar, Vipin; Sepolia, Shipra; Gupta, Shivangi; Singh, Harkanwal Preet

    2017-01-01

    Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI) questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1) absolutely not, (2) slightly, (3) somewhat, or (4) very much. All the results were recorded and statistical analyzed by SPSS software. Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality ( n = 38). Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla ( P < 0.001). The difference of average STAI-State subscore before and after the surgery was statistically significant ( P < 0.05; significant). Mandibular dental implants show more clamping (torque) than maxillary dental implants.

  13. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    Directory of Open Access Journals (Sweden)

    Sanjay Byakodi

    2017-01-01

    Full Text Available Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1 absolutely not, (2 slightly, (3 somewhat, or (4 very much. All the results were recorded and statistical analyzed by SPSS software. Results: Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality (n = 38. Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla (P < 0.001. The difference of average STAI-State subscore before and after the surgery was statistically significant (P < 0.05; significant. Conclusion: Mandibular dental implants show more clamping (torque than maxillary

  14. Conventional and advanced implant treatment in the type II diabetic patient: surgical protocol and long-term clinical results.

    Science.gov (United States)

    Tawil, Georges; Younan, Roland; Azar, Pierre; Sleilati, Ghassan

    2008-01-01

    To investigate the effect of type-2 diabetes on implant survival and complication rate. Prospective study enrolling type-2 diabetic patients suffering from edentulism, having a mean perioperative HbA1c level of 7.2%, and compliant with a maintenance program. All the patients underwent dental and periodontal examinations and had laboratory testing for HbA1c, fasting plasma glucose, blood lipids, and microalbuminuria. Nondiabetic patients matched for implant treatment indication served as controls. The influence of clinical diabetes-related factors and periodontal parameters (Plaque Index, bleeding on probing, probing depth) on implant survival were assessed via univariate then multivariate methods. Forty-five diabetic patients, followed for 1 to 12 years, mean age 64.7 years, received 255 implants: 143 following a classical protocol and 112 in cases of sinus floor elevation, immediate loading, and guided bone regeneration. Forty-five nondiabetic control patients received 244 implants: 142 following a classical protocol and 102 in cases of advanced surgery. Implant survival following conventional or advanced implant therapy was not statistically different between the well-controlled (HbA1c diabetic group was 97.2% (control 98.8%) and was not significantly different for age, gender, diabetes duration, smoking, or type of hypoglycemic therapy. The mean peri-implant bone loss was 0.41 +/- 0.58 mm (control, 0.49 +/- 0.64 mm). PI and BOP fairly correlated with postoperative complications. HbA1c was the only multivariate independent factor affecting the complication rate (P = .04). No statistically significant difference was found for patients (P = .81) or for implants (P = .66) for the advanced surgery cases or the conventional approach in diabetic patients compared to nondiabetic patients.

  15. Vacancy-type defects and their annealing processes in ion-implanted Si studied by a variable-energy positron beam

    International Nuclear Information System (INIS)

    Uedono, A.; Wei, L.; Tanigawa, S.; Sugiura, J.; Ogasawara, M.

    1992-01-01

    Vacancy-type defects in B + -, P + - and Si + -ion implanted SiO 2 (43 nm)/Si(100) and Si(100) were studied by a variable-energy positron beam. Depth distributions of vacancy-type defects were obtained from measurements of Doppler broadening profiles of the positron annihilation as a function of incident positron energy. For 200-keV P + -implanted specimen with a dose of 5 x 10 13 P/cm 2 , the damaged layers induced by ion-implantation were found to extend far beyond the stopping range of P-atoms. For 80-keV B + -implanted SiO 2 (43 nm)/Si(100) specimens with different ion-currents, an increase of the ion-current introduced a homogeneous amorphous layer in the subsurface region. Dominant defect species in B + - and P + -implanted specimen were identified as vacancy clusters from their annealing behavior. (author)

  16. Friction wear and dissolution of orthopedic implant systems

    International Nuclear Information System (INIS)

    Ektessabi, A.M.; Shikine, S.; Hamdi, M.; Kitamura, N.; Rokkum, M.; Johansson, C.

    2000-01-01

    Bio-medical implants release metallic elements during the long periods of time while inserted in the human body. The chemical interactions between the tissues and surface of the implants, and the mechanical friction of implants cause the release of metals into the human tissues. In this study we investigated the distribution and the chemical-state of the metallic elements in the tissues around a failed implant system using PIXE (proton induced x-ray emission) and SR-XRF (synchrotron radiation x-ray fluorescence) spectroscopies. The specimens were from the causes of patients with diagnosed arthritis. The implant consisted of a stem and a metal backing made of Ti-6Al-4V, an implant head made of stainless steel, and a polyethylene (PE) cup. Both the stem and the metal backing had a plasma-sprayed HAp surface coating. Distribution and concentration of dissolved elements in tissues surrounding implants were examined and quantified using PIXE analysis. Similar specimen from the same case was further investigated using SR-XRF analysis. Chemical-states of the dissolved elements were also studied by XAFS (x-ray absorption fine structure) analysis. From results of these measurements, it is confirmed that the tissues surrounding implants contained metallic elements such as Fe, Cr, Ni, and Ti. These elements are originated from the implant. Furthermore, it was made clear that the chemical-state of Fe had changed as a consequence of dissolution of Fe in the organic tissues. (author)

  17. Systemic conditions and treatments as risk for therapy with dental implants

    International Nuclear Information System (INIS)

    Arguedas Vega, Natalia; Alfaro Mayorga, Erika

    2013-01-01

    The possible risks for osseointegration are described in patients with specific systemic conditions, medical treatment such as radiation, cardiovascular diseases, HIV and smoking habit. The principal complications for osseointegration of diseases and systemic treatments are exposed. The review and search of the available literature are realized in databases. The scientific literature obtained from human studies has reported the survival of patients with dental implants. The implants are placed in patients with at least one of the conditions studied. The risks of the surgical procedures required for the placement of implants are analyzed in systemically compromised patients. Comparisons of patients with and without systemic conditions in controlled form have remained without analyzing. The level of evidence of absolute and relative contraindications has been low for the therapy with implants in patients with systemic diseases. The revised information is detailed according the systemic conditions, and each of them are evaluated separately [es

  18. Therapeutic interaction of systemically-administered mesenchymal stem cells with peri-implant mucosa.

    Directory of Open Access Journals (Sweden)

    Ryosuke Kondo

    Full Text Available OBJECTIVES: The objective of this study was to investigate the effect of systemically transplanted mesenchymal stem cells (MSCs on the peri-implant epithelial sealing around dental implants. MATERIALS AND METHODS: MSCs were isolated from bone marrow of donor rats and expanded in culture. After recipient rats received experimental titanium dental implants in the bone sockets after extraction of maxillary right first molars, donor rat MSCs were intravenously transplanted into the recipient rats. RESULTS: The injected MSCs were found in the oral mucosa surrounding the dental implants at 24 hours post-transplantation. MSC transplantation accelerated the formation of the peri-implant epithelium (PIE-mediated mucosa sealing around the implants at an early stage after implantation. Subsequently, enhanced deposition of laminin-332 was found along the PIE-implant interface at 4 weeks after the replacement. We also observed enhanced attachment and proliferation of oral mucous epithelial cells. CONCLUSION: Systemically transplanted MSCs might play a critical role in reinforcing the epithelial sealing around dental implants.

  19. The Computer in a Programmable Implantable Medication System (PIMS)

    OpenAIRE

    Sanders, K. H.; Radford, W. E.

    1982-01-01

    The Programmable Implantable Medication System (PIMS) developed at APL can be used in the treatment of diabetes, reproductive hormone dysfunction, hypertension, cancer, chronic pain, thrombosis, and the delivery of growth hormone. The Implantable Programmable Infusion Pump (IPIP) is the implanted element of PIMS. Under control of a microprocessor, the IPIP administers medication and stores data pertaining to its operation. An external unit can read out the stored data, as well as program the ...

  20. Effects of implant system, impression technique, and impression material on accuracy of the working cast.

    Science.gov (United States)

    Wegner, Kerstin; Weskott, Katharina; Zenginel, Martha; Rehmann, Peter; Wöstmann, Bernd

    2013-01-01

    This in vitro study aimed to identify the effects of the implant system, impression technique, and impression material on the transfer accuracy of implant impressions. The null hypothesis tested was that, in vitro and within the parameters of the experiment, the spatial relationship of a working cast to the placement of implants is not related to (1) the implant system, (2) the impression technique, or (3) the impression material. A steel maxilla was used as a reference model. Six implants of two different implant systems (Standard Plus, Straumann; Semados, Bego) were fixed in the reference model. The target variables were: three-dimensional (3D) shift in all directions, implant axis direction, and rotation. The target variables were assessed using a 3D coordinate measuring machine, and the respective deviations of the plaster models from the nominal values of the reference model were calculated. Two different impression techniques (reposition/pickup) and four impression materials (Aquasil Ultra, Flexitime, Impregum Penta, P2 Magnum 360) were investigated. In all, 80 implant impressions for each implant system were taken. Statistical analysis was performed using multivariate analysis of variance. The implant system significantly influenced the transfer accuracy for most spatial dimensions, including the overall 3D shift and implant axis direction. There was no significant difference between the two implant systems with regard to rotation. Multivariate analysis of variance showed a significant effect on transfer accuracy only for the implant system. Within the limits of the present study, it can be concluded that the transfer accuracy of the intraoral implant position on the working cast is far more dependent on the implant system than on the selection of a specific impression technique or material.

  1. Implantation doping of GaN

    International Nuclear Information System (INIS)

    Zolper, J.C.

    1996-01-01

    Ion implantation has played an enabling role in the realization of many high performance photonic and electronic devices in mature semiconductor materials systems such as Si and GaAs. This can also be expected to be the case in III-Nitride based devices as the material quality continues to improve. This paper reviews the progress in ion implantation processing of the III-Nitride materials, namely, GaN, AlN, InN and their alloys. Details are presented of the successful demonstrations of implant isolation as well as n- and p-type implantation doping of GaN. Implant doping has required activation annealing at temperatures in excess of 1,000 C. The nature of the implantation induced damage and its response to annealing is addressed using Rutherford Backscattering. Finally, results are given for the first demonstration of a GaN device fabricated using ion implantation doping, a GaN junction field effect transistor (JFET)

  2. P-type single-crystalline ZnO films obtained by (N,O) dual implantation through dynamic annealing process

    Science.gov (United States)

    Zhang, Zhiyuan; Huang, Jingyun; Chen, Shanshan; Pan, Xinhua; Chen, Lingxiang; Ye, Zhizhen

    2016-12-01

    Single-crystalline ZnO films were grown on a-plane sapphire substrates by plasma-assisted molecular beam epitaxy technique. The films have been implanted with fixed fluence of 120 keV N and 130 keV O ions at 460 °C. Hall measurements show that the dually-implanted single-crystalline ZnO films exhibit p-type characteristics with hole concentration in the range of 2.1 × 1018-1.1 × 1019 cm-3, hole mobilities between 1.6 and 1.9 cm2 V-1 s-1, and resistivities in the range of 0.353-1.555 Ω cm. The ZnO films exhibit (002) (c-plane) orientation as identified by the X-ray diffraction pattern. It is confirmed that N ions were effectively implanted by SIMS results. Raman spectra, polarized Raman spectra, and X-ray photoelectron spectroscopy results reflect that the concentration of oxygen vacancies is reduced, which is attributed to O ion implantation. It is concluded that N and O implantation and dynamic annealing play a critical role in forming p-type single-crystalline ZnO films.

  3. Cutaneous and systemic hypersensitivity reactions to metallic implants.

    Science.gov (United States)

    Basko-Plluska, Juliana L; Thyssen, Jacob P; Schalock, Peter C

    2011-01-01

    Cutaneous reactions to metal implants, orthopedic or otherwise, are well documented in the literature. The first case of a dermatitis reaction over a stainless steel fracture plate was described in 1966. Most skin reactions are eczematous and allergic in nature, although urticarial, bullous, and vasculitic eruptions may occur. Also, more complex immune reactions may develop around the implants, resulting in pain, inflammation, and loosening. Nickel, cobalt, and chromium are the three most common metals that elicit both cutaneous and extracutaneous allergic reactions from chronic internal exposure. However, other metal ions as well as bone cement components can cause such hypersensitivity reactions. To complicate things, patients may also develop delayed-type hypersensitivity reactions to metals (ie, in-stent restenosis, prosthesis loosening, inflammation, pain, or allergic contact dermatitis) following the insertion of intravascular stents, dental implants, cardiac pacemakers, or implanted gynecologic devices. Despite repeated attempts by researchers and clinicians to further understand this difficult area of medicine, the association between metal sensitivity and cutaneous allergic reactions remains to be fully understood. This review provides an update of the current knowledge in this field and should be valuable to health care providers who manage patients with conditions related to this field.

  4. The bacterial sealing capacity of morse taper implant-abutment systems in vitro.

    Science.gov (United States)

    Ranieri, Rogerio; Ferreira, Andreia; Souza, Emmanuel; Arcoverde, Joao; Dametto, Fabio; Gade-Neto, Cicero; Seabra, Flavio; Sarmento, Carlos

    2015-05-01

    The use of Morse taper systems in dental implantology has been associated widely with a more precise adaptation between implants and their respective abutments. This may lead to an increase in the stability of the implant system and may also prevent microbial invasion through the implant-abutment interface. The aim of this study was to investigate in vitro the ability of four commercially available Morse taper system units to impede bacterial penetration through their implant-abutment interfaces. Abutments were screwed onto the implants, and the units were subsequently immersed in Streptococcus sanguinis bacterial broth (1 × 10(8) colony forming units/mL) for 48 hours. The units were examined by scanning electron microscopy (SEM) under three conditions: 1) with the implant-abutment components assembled as units to investigate for both the existence of microgaps and the presence of bacteria; 2) with the implants and abutments separated for examination of internal surfaces; and 3) with the implant-abutment components again assembled as units to measure any microgaps detected. The mean size of the microgaps in each unit was determined by measuring, under SEM, their width in four equidistant points. Microgaps were detected in all units with no significant differences in dimension (Kruskal-Wallis test, P >0.05). Within all units, the presence of bacteria was also observed. The seals provided by the interfaces of the commercially available Morse taper implant-abutment units tested were not sufficiently small to shield the implant from bacterial penetration.

  5. Health-economic evaluation in implant trials: design considerations.

    Science.gov (United States)

    Alt, Volker; Pavlidis, Theodoros; Szalay, Gabor; Heiss, Christian; Schnettler, Reinhard

    2009-01-01

    In today's world, demonstration of the safety, efficacy, and quality of a new treatment strategy is no longer sufficient in many countries for market entry and reimbursement in the public healthcare system. This implies that new implants in orthopedic and orthopedic trauma surgery not only must be shown to lead to better medical outcome compared with the standard of care implant, but also must be shown to exhibit "good value" for the money for the public health-care system based on sound economic data from health-economic studies. The purpose of this article is to elucidate a framework for health-economic aspects alongside implant trials, with the assumption that the new implant is more costly but potentially better than the control implant. Cost-effectiveness, cost-utility, and cost-benefit studies are suitable for the assessment of the health-economic value of a new implant. The following criteria should be considered for a health-economic study design in the context with an implant: i) it should state medical benefits of the new implant compared with the control implant; ii) it should precise the type of health economic study; iii) it should define the methodological approach, perspective of the study, and types of costs; iv) if necessary, it should state discount costs and/benefits; and v) a sound sensitivity analysis should be included. Furthermore, close cooperation between researchers, clinicians, and health economists is essential.

  6. The effects of implant-macro design on stress quantity and distribution around three types of fixtures by photo-elastic analysis

    OpenAIRE

    Shams Ak; Eyvaz ziaee A; Esfahanizadeh G; Ghoseiri R

    2011-01-01

    "nBackground and Aims: Considering the great incidence of implant failures due to high stresses around implant and at bone-implant interfaces, the aim of this study was to compare the effects of three different implant-macro designs on the quantity and distribution pattern of stresses around implants."nMaterials and Methods: In this experimental in vitro study, three types of implants including Biohorizon (4×10.5 mm), Iler (4×10 mm), and Swiss Plus (4.1×...

  7. Properties and local environment of p-type and photoluminescent rare earths implanted into ZnO single crystals

    CERN Document Server

    Rita, EMC; Wahl, U; Soares, JC

    This thesis presents an experimental study of the local environment of p-type and Rare- Earth dopants implanted in ZnO single-crystals (SCs). Various nuclear and bulk property techniques were combined in the following evaluations: Implantation damage annealing was evaluated in ZnO SCs implanted with Fe, Sr and Ca. P-type dopants Cu and Ag implanted ZnO SCs were studied revealing that the solubility of Cu in substituting Zn is considerably higher than that of Ag. These results are discussed within the scope of the ZnO p-type doping problematic with these elements. Experimental proofs of the As “anti-site” behavior in ZnO were for the first time attained, i.e., the majority of As atoms are substitutional at the Zn site (SZn), possibly surrounded by two Zn vacancies (VZn). This reinforces the theoretical prediction that As acts as an acceptor in ZnO via the AsZn-2VZn complex formation. The co-doping of ZnO SC with In (donor) and As (acceptor) was addressed. The most striking result is the possible In-As “p...

  8. [Design and application of implantable medical device information management system].

    Science.gov (United States)

    Cao, Shaoping; Yin, Chunguang; Zhao, Zhenying

    2013-03-01

    Through the establishment of implantable medical device information management system, with the aid of the regional joint sharing of resources, we further enhance the implantable medical device traceability management level, strengthen quality management, control of medical risk.

  9. Columnar transmitter based wireless power delivery system for implantable device in freely moving animals.

    Science.gov (United States)

    Eom, Kyungsik; Jeong, Joonsoo; Lee, Tae Hyung; Lee, Sung Eun; Jun, Sang Bum; Kim, Sung June

    2013-01-01

    A wireless power delivery system is developed to deliver electrical power to the neuroprosthetic devices that are implanted into animals freely moving inside the cage. The wireless powering cage is designed for long-term animal experiments without cumbersome wires for power supply or the replacement of batteries. In the present study, we propose a novel wireless power transmission system using resonator-based inductive links to increase power efficiency and to minimize the efficiency variations. A columnar transmitter coil is proposed to provide lateral uniformity of power efficiency. Using this columnar transmitter coil, only 7.2% efficiency fluctuation occurs from the maximum transmission efficiency of 25.9%. A flexible polymer-based planar type receiver coil is fabricated and assembled with a neural stimulator and an electrode. Using the designed columnar transmitter coil, the implantable device successfully operates while it moves freely inside the cage.

  10. Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: a finite element analysis.

    Science.gov (United States)

    Hong, Hae Ryong; Pae, Ahran; Kim, Yooseok; Paek, Janghyun; Kim, Hyeong-Seob; Kwon, Kung-Rock

    2012-01-01

    The aim of this study was to analyze and compare the level and distribution of peri-implant bone stresses associated with mandibular two-implant overdentures with different implant positions. Mathematical models of mandibles and overdentures were designed using finite element analysis software. Two intraosseous implants and ball attachment systems were placed in the interforaminal region. The overdenture, which was supported by the two implants, was designed to withstand bilateral and unilateral vertical masticatory loads (total 100 N). In all, eight types of models, which differed according to assigned implant positions, height of attachments, and angulation, were tested: MI (model with implants positioned in the lateral incisor sites), MC (implants in canine sites), MP (implants in premolar sites), MI-Hi (greater height of attachments), MC-M (canine implants placed with mesial inclination), MC-D (canine implants placed with distal inclination), MC-B (canine implants placed with buccal inclination), and MC-L (canine implants placed with lingual inclination). Peri-implant bone stress levels associated with overdentures retained by lateral incisor implants resulted in the lowest stress levels and the highest efficiency in distributing peri-implant stress. MI-Hi showed increased stress levels and decreased efficiency in stress distribution. As the implants were inclined, stress levels increased and the efficiency of stress distribution decreased. Among the inclined models, MC-B showed the lowest stress level and best efficiency in stress distribution. The lowest stress and the best stability of implants in mandibular two-implant overdentures were obtained when implants were inserted in lateral incisor areas with shorter attachments and were placed parallel to the long axes of the teeth.

  11. Beryllium implant activation and damage recovery study in n-type GaSb

    Science.gov (United States)

    Rahimi, N.; Behzadirad, M.; Renteria, Emma J.; Shima, D. M.; Muniz, Ayse J.; Busani, T.; Lavrova, Olga; Balakrishnan, G.; Lester, L. F.

    2014-03-01

    Damage induced by the implantation of beryllium in n-type GaSb and its removal by Rapid Thermal Annealing (RTA) are studied in detail by Atomic Force Microscopy (AFM), Cross Sectional Transmission Electron Microscopy (XTEM) and Energy Dispersive X-ray Spectroscopy (EDS). RTA has been implemented with different times and temperatures in order to optimize ion activation and to avoid Sb outdiffusion during the process. Results indicate a lattice quality that is close to pristine GaSb for samples annealed at 600 °C for 10s using a thick Si3N4 capping layer. Electrical response of the implanted diodes is measured and characterized as function of different annealing conditions.

  12. A comparision of two types of decalcified freeze-dried bone allograft in treatment of dehiscence defects around implants in dogs

    Directory of Open Access Journals (Sweden)

    Ahmad Moghareh Abed

    2011-01-01

    Full Text Available Background: Decalcified freeze-dried bone allograft (DFDBA may have the potential to enhance bone formation around dental implants. Our aim in this study was the evaluation and comparison of two types of DFDBA in treatment of dehiscence defects around Euroteknika® implants in dogs. Methods : In this prospective clinical trial animal study, all mandibular premolars of three Iranian dogs were extracted. After 3 months of healing, fifteen SLA type Euroteknika® dental implants (Natea with 4.1mm diameter and 10mm length were placed in osteotomy sites with dehiscence defects of 5mm length, 4 mm width, and 3mm depth. Guided bone regeneration (GBR procedures were performed using Cenobone and collagen membrane for six implants, the other six implants received Dembone and collagen membrane and the final three implants received only collagen membrane. All implants were submerged. After 4 months of healing, implants were uncovered and stability (Implant Stability Quotient of all implants was measured. Then, block biopsies of each implant site were taken and processed for ground sectioning and histomorphometric analysis. The data was analyzed by ANOVA and Pearson tests. P value less than 0.05 was considered to be significant. Results: All implants osseointegrated after 4 months. The mean values of bone to implant contact for histomorphometric measurements of Cenobone, Denobone, and control groups were 77.36 ± 9.96%, 78.91 ± 11.9% and 71.56 ± 5.61% respectively, with no significant differences among the various treatment groups. The correlation of Implant Stability Quotient and histomorphometric techniques was 0.692. Conclusion: In treating of dehiscence defects with GBR technique in this study, adding DFDBA did not significantly enhance the percentages of bone-to-implant contact measurements; and Implant Stability Quotient Resonance Frequency Analysis appeared to be a precise technique.

  13. Three-dimensional accuracy of plastic transfer impression copings for three implant systems.

    Science.gov (United States)

    Teo, Juin Wei; Tan, Keson B; Nicholls, Jack I; Wong, Keng Mun; Uy, Joanne

    2014-01-01

    The purpose of this study was to compare the three-dimensional accuracy of indirect plastic impression copings and direct implant-level impression copings from three implant systems (Nobel Biocare [NB], Biomet 3i [3i], and Straumann [STR]) at three interimplant buccolingual angulations (0, 8, and 15 degrees). Two-implant master models were used to simulate a three-unit implant fixed partial denture. Test models were made from Impregum impressions using direct implant-level impression copings (DR). Abutments were then connected to the master models for impressions using the plastic impression copings (INDR) at three different angulations for a total of 18 test groups (n = 5 in each group). A coordinate measuring machine was used to measure linear distortions, three-dimensional (3D) distortions, angular distortions, and absolute angular distortions between the master and test models. Three-way analysis of variance showed that the implant system had a significant effect on 3D distortions and absolute angular distortions in the x- and y-axes. Interimplant angulation had a significant effect on 3D distortions and absolute angular distortions in the y-axis. Impression technique had a significant effect on absolute angular distortions in the y-axis. With DR, the NB and 3i systems were not significantly different. With INDR, 3i appeared to have less distortion than the other systems. Interimplant angulations did not significantly affect the accuracy of NBDR, 3iINDR, and STRINDR. The accuracy of INDR and DR was comparable at all interimplant angulations for 3i and STR. For NB, INDR was comparable to DR at 0 and 8 degrees but was less accurate at 15 degrees. Three-dimensional accuracy of implant impressions varied with implant system, interimplant angulation, and impression technique.

  14. Depth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study.

    Science.gov (United States)

    Lenders, Guy D; Collas, Valérie; Hernandez, José Maria; Legrand, Victor; Danenberg, Haim D; den Heijer, Peter; Rodrigus, Inez E; Paelinck, Bernard P; Vrints, Christiaan J; Bosmans, Johan M

    2014-10-20

    Transcatheter Aortic Valve Implantation (TAVI) is now considered an indispensable treatment strategy in high operative risk patients with severe, symptomatic aortic stenosis. However, conduction disturbances and the need for Permanent Pacemaker (PPM) implantation after TAVI with the CoreValve prosthesis still remain frequent. We aimed to evaluate the implantation depth, the incidence and predictors of new conduction disturbances, and the need for PPM implantation within the first month after TAVI, using the new Accutrak CoreValve delivery system (ACV), compared to the previous generation CoreValve (non-ACV). In 5 experienced TAVI-centers, a total of 120 consecutive non-ACV and 112 consecutive ACV patients were included (n=232). The mean depth of valve implantation (DVI) was 8.4±4.0 mm in the non-ACV group and 7.1±4.0 mm in the ACV group (p=0.034). The combined incidence of new PPM implantation and new LBBB was 71.2% in the non-ACV group compared to 50.5% in the ACV group (p=0.014). DVI (p=0.002), first degree AV block (p=0.018) and RBBB (p<0.001) were independent predictors of PPM implantation. DVI (p<0.001) and pre-existing first degree AV-block (p=0.021) were identified as significant predictors of new LBBB. DVI is an independent predictor of TAVI-related conduction disturbances and can be reduced by using the newer CoreValve Accutrak delivery system, resulting in a significantly lower incidence of new LBBB and new PPM implantation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Comparison of posterior capsule folds following intracapsular implantation of three types of intraocular lenses with different haptic design

    Directory of Open Access Journals (Sweden)

    Ling-Lin Zhang

    2018-04-01

    Full Text Available AIM: To compare the incidence of posterior capsule folds among different types of intraocular lens(IOLto determine risk factors of posterior capsule folds. METHODS:It was a retrospective study. We collected the cases in which the patients underwent phacoemulsification(PHACOand IOL implantation and at least one of the three types of IOL was implanted, including 2-haptic 3-piece IOLs(HOYA PY60AD, 4-haptic 1-piece IOLs(Bausch & Lomb AO, 2-haptic 1-piece IOLs(AMO Tecnis ZCB00. The posterior capsule folds were measured using slit lamp microscope 2d after the surgery. Information of patient's age, gender, length of ocular axis, intraocular pressure, types of IOL were recorded. Posterior capsule fold risk indicators were identified by using logistic regression analysis. RESULTS: One hundred eighty-seven patients(242 eyeshad been collected, including 80 eyes implanted with HOYA PY60AD IOLs, 81 eyes implanted with Bausch & Lomb AO IOLs, 81 eyes implanted with AMO Tecnis ZCB00 IOLs. The incidence of posterior capsule folds of patients implanted with HOYA PY60AD IOLs was significantly higher than those of patients implanted with AMO Tecnis ZCB00 IOLs(56.3% vs 38.3%, P=0.027. While the incidence of patients implanted with Bausch & Lomb AO IOLs was significantly lower than those of patients implanted with AMO Tecnis ZCB00 IOLs(14.8% vs 38.3%, P=0.001. Multi-factor logistics regression analysis demonstrated that independent risk factors were type of IOLs and length of ocular axis. Compared with AMO Tecnis ZCB00 IOLs, using HOYA PY60AD IOLs increased the risk of posterior capsule folds \\〖P=0.020, OR(95%CI=2.145(1.129,4.073\\〗, while using Bausch & Lomb AO IOLs reduced the risk \\〖P=0.001, OR(95%CI=0.274(0.127, 0.591\\〗. Shorter ocular axis might increase the risk of posterior capsule folds \\〖P=0.012, OR(95%CI=0.669(0.489, 0.915\\〗. CONCLUSION: Haptic design should be an important consideration in IOL design. Compared with AMO Tecnis ZCB00 IOLs

  16. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Minatel, Lurian [Pró-Reitoria de Pesquisa e Pós-graduação (PRPPG), Universidade do Sagrado Coração, USC, 10–50 Irmã Armindal, Jardim Brasil, Bauru, 17011–160, SP (Brazil); Verri, Fellippo Ramos [Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, 1193 José Bonifácio Street, Vila Mendonça, Araçatuba 16015–050 (Brazil); Kudo, Guilherme Abu Halawa [Pró-Reitoria de Pesquisa e Pós-graduação (PRPPG), Universidade do Sagrado Coração, USC, 10–50 Irmã Armindal, Jardim Brasil, Bauru, 17011–160, SP (Brazil); Faria Almeida, Daniel Augusto de; Souza Batista, Victor Eduardo de; Aparecido Araujo Lemos, Cleidiel; Piza Pellizzer, Eduardo [Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, 1193 José Bonifácio Street, Vila Mendonça, Araçatuba 16015–050 (Brazil); and others

    2017-02-01

    A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology. Four models were simulated (with each containing a single prosthesis over the implant) in the molar region, with the following specifications: M1 and M2 is an external hexagonal implant on a regular platform; M3 is an external hexagonal implant using PSW concept; and M4 is a Morse taper implant. The modeling process involved the use of images from InVesalius CT (computed tomography) processing software, which were refined using Rhinoceros 4.0 and SolidWorks 2011 CAD software. The models were then exported into the finite element program (FEMAP 11.0) to configure the meshes. The models were processed using NeiNastram software. The main results are that M1 (regular diameter 4 mm) had the highest stress concentration area and highest microstrain concentration for bone tissue, dental implants, and the retaining screw (P < 0.05). Using the PSW concept increases the area of the stress concentrations in the retaining screw (P < 0.05) more than in the regular platform implant. It was concluded that the increase in diameter is beneficial for stress distribution and that the PSW concept had higher stress concentrations in the retaining screw and the crown compared to the regular platform implant. - Highlights: • The external hexagon implants was unfavorable biomechanical. • The Morse taper implant presented the best biomechanical result. • Platform switching concept increased stress in screw-retained prostheses.

  17. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses

    International Nuclear Information System (INIS)

    Minatel, Lurian; Verri, Fellippo Ramos; Kudo, Guilherme Abu Halawa; Faria Almeida, Daniel Augusto de; Souza Batista, Victor Eduardo de; Aparecido Araujo Lemos, Cleidiel; Piza Pellizzer, Eduardo

    2017-01-01

    A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology. Four models were simulated (with each containing a single prosthesis over the implant) in the molar region, with the following specifications: M1 and M2 is an external hexagonal implant on a regular platform; M3 is an external hexagonal implant using PSW concept; and M4 is a Morse taper implant. The modeling process involved the use of images from InVesalius CT (computed tomography) processing software, which were refined using Rhinoceros 4.0 and SolidWorks 2011 CAD software. The models were then exported into the finite element program (FEMAP 11.0) to configure the meshes. The models were processed using NeiNastram software. The main results are that M1 (regular diameter 4 mm) had the highest stress concentration area and highest microstrain concentration for bone tissue, dental implants, and the retaining screw (P < 0.05). Using the PSW concept increases the area of the stress concentrations in the retaining screw (P < 0.05) more than in the regular platform implant. It was concluded that the increase in diameter is beneficial for stress distribution and that the PSW concept had higher stress concentrations in the retaining screw and the crown compared to the regular platform implant. - Highlights: • The external hexagon implants was unfavorable biomechanical. • The Morse taper implant presented the best biomechanical result. • Platform switching concept increased stress in screw-retained prostheses.

  18. Toward angiogenesis of implanted bio-artificial liver using scaffolds with type I collagen and adipose tissue-derived stem cells.

    Science.gov (United States)

    Lee, Jae Geun; Bak, Seon Young; Nahm, Ji Hae; Lee, Sang Woo; Min, Seon Ok; Kim, Kyung Sik

    2015-05-01

    Stem cell therapies for liver disease are being studied by many researchers worldwide, but scientific evidence to demonstrate the endocrinologic effects of implanted cells is insufficient, and it is unknown whether implanted cells can function as liver cells. Achieving angiogenesis, arguably the most important characteristic of the liver, is known to be quite difficult, and no practical attempts have been made to achieve this outcome. We carried out this study to observe the possibility of angiogenesis of implanted bio-artificial liver using scaffolds. This study used adipose tissue-derived stem cells that were collected from adult patients with liver diseases with conditions similar to the liver parenchyma. Specifically, microfilaments were used to create an artificial membrane and maintain the structure of an artificial organ. After scratching the stomach surface of severe combined immunocompromised (SCID) mice (n=4), artificial scaffolds with adipose tissue-derived stem cells and type I collagen were implanted. Expression levels of angiogenesis markers including vascular endothelial growth factor (VEGF), CD34, and CD105 were immunohistochemically assessed after 30 days. Grossly, the artificial scaffolds showed adhesion to the stomach and surrounding organs; however, there was no evidence of angiogenesis within the scaffolds; and VEGF, CD34, and CD105 expressions were not detected after 30 days. Although implantation of cells into artificial scaffolds did not facilitate angiogenesis, the artificial scaffolds made with type I collagen helped maintain implanted cells, and surrounding tissue reactions were rare. Our findings indicate that type I collagen artificial scaffolds can be considered as a possible implantable biomaterial.

  19. Peri-Implant Strain in an In Vitro Model.

    Science.gov (United States)

    Hussaini, Souheil; Vaidyanathan, Tritala K; Wadkar, Abhinav P; Quran, Firas A Al; Ehrenberg, David; Weiner, Saul

    2015-10-01

    An in vitro experimental model was designed and tested to determine the influence that peri-implant strain may have on the overall crestal bone. Strain gages were attached to polymethylmethacrylate (PMMA) models containing a screw-type root form implant at sites 1 mm from the resin-implant interface. Three different types of crown superstructures (cemented, 1-screw [UCLA] and 2-screw abutment types) were tested. Loading (1 Hz, 200 N load) was performed using a MTS Mechanical Test System. The strain gage data were stored and organized in a computer for statistical treatment. Strains for all abutment types did not exceed the physiological range for modeling and remodeling of cancellous bone, 200-2500 με (microstrain). For approximately one-quarter of the trials, the strain values were less than 200 με the zone for bone atrophy. The mean microstrain obtained was 517.7 με. In conclusion, the peri-implant strain in this in vitro model did not exceed the physiologic range of bone remodeling under axial occlusal loading.

  20. ISHTE deep-ocean corers and heater-implant system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Olson, L. O.; Harrison, J. G.

    1982-09-01

    Seafloor instrumentation systems are being developed for the In-Situ Heat Transfer Experiment (ISHTE) to determine the thermal conductivity of deep ocean sediments. As part of the experiment, a heat canister will be implanted into the sediment. Also, after about one year on the seafloor, core samplers are to be actuated to gather sediment samples. This report describes the deep ocean piston corers and the heater-implant drive system.

  1. Implant-Abutment Contact Surfaces and Microgap Measurements of Different Implant Connections Under 3-Dimensional X-Ray Microtomography.

    Science.gov (United States)

    Scarano, Antonio; Valbonetti, Luca; Degidi, Marco; Pecci, Raffaella; Piattelli, Adriano; de Oliveira, P S; Perrotti, Vittoria

    2016-10-01

    The presence of a microgap between implant and abutment could produce a bacterial reservoir which could interfere with the long-term health of the periimplant tissues. The aim of this article was to evaluate, by x-ray 3-dimensional microtomography, implant-abutment contact surfaces and microgaps at the implant-abutment interface in different types of implant-abutment connections. A total of 40 implants were used in this in vitro study. Ten implants presented a screw-retained internal hexagon abutment (group I), 10 had a Morse Cone taper internal connection (group II), 10 another type of Morse Cone taper internal connection (group III), and 10 had a screwed trilobed connection (group IV). In both types of Morse Cone internal connections, there was no detectable separation at the implant-abutment in the area of the conical connection, and there was an absolute congruity without any microgaps between abutment and implant. No line was visible separating the implant and the abutment. On the contrary, in the screwed abutment implants, numerous gaps and voids were present. The results of this study support the hypothesis that different types of implant-abutment joints are responsible for the observed differences in bacterial penetration.

  2. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  3. Martensitic transformation of type 304 stainless steel by high-energy ion implantation

    International Nuclear Information System (INIS)

    Chayahara, A.; Satou, M.; Nakashima, S.; Hashimoto, M.; Sasaki, T.; Kurokawa, M.; Kiyama, S.

    1991-01-01

    The effect of high-energy ion implantation on the structural changes of type 304 stainless steel were investigated. Gold, copper and silicon ions with an energy of 1.5 MeV was implanted into stainless steel. The fluences were in the range from 5x10 15 to 10 17 ions/cm 2 . It was found that the structure of stainless steel was transformed form the austenitic to the martensitic structure by these ion implantations. This structural change was investigated by means of X-ray diffraction and transmission electron microscopy (TEM). The depth profile of the irradiated ions was also analyzed by secondary ion mass spectroscopy (SIMS) and glow discharge spectroscopy (GDS). The degree of martensitic transformation was found to be strongly dependent on the surface pretreatment, either mechanical or electrolytic polishing. When the surface damages or strains by mechanical polishing were present, the martensitic transformation was greatly accelerated presumably due to the combined action of ion irradiation and strain-enhanced transformation. Heavier ions exhibit a high efficiency for the transformation. (orig.)

  4. Three-Dimensional Implant Positioning with a Piezosurgery Implant Site Preparation Technique and an Intraoral Surgical Navigation System: Case Report.

    Science.gov (United States)

    Pellegrino, Gerardo; Taraschi, Valerio; Vercellotti, Tomaso; Ben-Nissan, Besim; Marchetti, Claudio

    This case report describes new implant site preparation techniques joining the benefits of using an intraoral navigation system to optimize three-dimensional implant site positioning in combination with an ultrasonic osteotomy. A report of five patients is presented, and the implant positions as planned in the navigation software with the postoperative scan image were compared. The preliminary results are useful, although further clinical studies with larger populations are needed to confirm these findings.

  5. Gel-type autologous chondrocyte (Chondron™ implantation for treatment of articular cartilage defects of the knee

    Directory of Open Access Journals (Sweden)

    Chun Chung-Woo

    2010-05-01

    Full Text Available Abstract Background Gel-type autologous chondrocyte (Chondron™ implantations have been used for several years without using periosteum or membrane. This study involves evaluations of the clinical results of Chondron™ at many clinical centers at various time points during the postoperative patient follow-up. Methods Data from 98 patients with articular cartilage injury of the knee joint and who underwent Chondron™ implantation at ten Korean hospitals between January 2005 and November 2008, were included and were divided into two groups based on the patient follow-up period, i.e. 13~24-month follow-up and greater than 25-month follow-up. The telephone Knee Society Score obtained during telephone interviews with patients, was used as the evaluation tool. Results On the tKSS-A (telephone Knee Society Score-A, the score improved from 43.52 ± 20.20 to 89.71 ± 13.69 (P Conclusion Gel-type autologous chondrocyte implantation for chondral knee defects appears to be a safe and effective method for both decreasing pain and improving knee function.

  6. Group D. Initiator paper. Implants--peri-implant (hard and soft tissue) interactions in health and disease: the impact of explosion of implant manufacturers.

    Science.gov (United States)

    Ivanovski, Saso

    2015-01-01

    1. The best-documented implants have a threaded solid screw-type design and are manufactured from commercially pure (grade IV) titanium. There is good evidence to support implants ≥ 6 mm in length, and ≥ 3 mm in diameter. 2. Integrity of the seal between the abutment and the implant is important for several reasons, including minimization of mechanical and biological complications and maintaining marginal bone levels. Although the ideal design features of the implant-abutment connection have not been determined, an internal connection, micro-grooves at the implant collar, and horizontal offset of the implant-abutment junction (platform switch) appear to impart favorable properties. 3. Implants with moderately rough implant surfaces provide advantages over machined surfaces in terms of the speed and extent of osseointegration. While the favorable performances of both minimally and moderately rough surfaces are supported by long-term data, moderately rough surfaces provide superior outcomes in compromised sites, such as the posterior maxilla. 4. Although plaque is critical in the progression of peri-implantitis, the disease has a multi-factorial aetiology, and may be influenced by poor integrity of the abutment/implant connection. Iatrogenic factors, such as the introduction of a foreign body. (e.g., cement) below the mucosal margin, can be important contributors. 5. Clinicians should exercise caution when using a particular implant system, ensuring that the implant design is appropriate and supported by scientific evidence. Central to this is access to and participation in quality education on the impact that implant characteristics can have on clinical outcomes. Caution should be exercised in utilizing non-genuine restorative componentry that may lead to a poor implant-abutment fit and subsequent technical and biological complications.

  7. Design of an end station for a high current ion implantation system

    International Nuclear Information System (INIS)

    Kranik, J.R.

    1979-01-01

    During the last 4 to 5 years IBM has been involved in an effort to develop a high current Ion Implantation system with pre-deposition capabilities. The system is dedicated to Arsenic implants, involving doses > 1 x 10 15 ions/cm 2 in the energy range of 30 to 60 keV. A major portion of this effort involved the design of an associated end station capable of producing high uniformity implants with beam currents in the 0.5 to 6.0 mA range. The end station contains all components from the exit of the analyzing magnet, including the exit beamline, process chamber, scan system, wafer handling system, high vacuum pumping package, beam optics, dosimetry system, and associated electronic controls. The unit was restricted to a six wafer (82 mm) batch size to maintain process line compatibility. In addition, implant dose non-uniformity objectives were established at +- 3% (2σ) within a wafer and +- 2% (2σ) wafer-to-wafer. Also, the system was to be capable of implanting 24 wafers/hour at a dose of 7.5 x 10 15 ions/cm 2 . Major consideration in the design was afforded to high reliability, ease of maintenance and production level throughput capabilities. The rationale and evolution of the final end station design is described. (author)

  8. Local and systemic changes associated with long-term, percutaneous, static implantation with titanium alloys in rhesus macaques (Macaca mulatta)

    Energy Technology Data Exchange (ETDEWEB)

    Frydman, Galit F.; Marini, Robert P.; Bakthavatchalu, Vasudevan; Biddle, Kathleen; Muthupalani, Sureshkumar; Vanderburg, Charles R.; Lai, Barry; Bendapudi, Pavan K.; Tompkins, Ronald G.; Fox, James G.

    2017-04-01

    Metal alloys are frequently used as implant materials in veterinary medicine. Recent studies suggest that many types of metal alloys may induce both local and systemic inflammatory responses. In this study, 37 rhesus macaques with long-term skull-anchored percutaneous titanium alloy implants (0-14 years duration) were evaluated for changes in their hematology, coagulation and serum chemistry profiles. Negative controls (n=28) did not have implants. All of the implanted animals were on IACUC-approved protocols and were not implanted for the purpose of this study. Animals with implants had significantly higher plasma D-dimer and lower antithrombin III concentrations compared with nonimplanted animals (p-values < 0.05). Additionally, animals with implants had significantly higher globulin, and lower albumin and calcium concentrations compared with nonimplanted animals (p-values < 0.05). Many of these changes were positively correlated with duration of implantation as well as the number of implants. Chronic bacterial infection was observed on the skin around many of the implant sites, and within deeper tissues. Representative histopathology around the implant site of two implanted animals revealed chronic suppurative to pyogranulomatous inflammation extending from the skin to the dura mater. X-ray fluorescence microscopy of tissue biopsies from the implant site of the same two animals revealed significant increases in free metal ions within the tissue, including titanium and iron. Free metal ions persisted in the tissues up to 6 months postexplant. These results suggest that long-term skull-anchored percutaneous titanium alloy implants results in localized inflammation, chronic infection, and leaching of metal ions into local tissues.

  9. Electroacoustic verification of frequency modulation systems in cochlear implant users.

    Science.gov (United States)

    Fidêncio, Vanessa Luisa Destro; Jacob, Regina Tangerino de Souza; Tanamati, Liége Franzini; Bucuvic, Érika Cristina; Moret, Adriane Lima Mortari

    2017-12-26

    The frequency modulation system is a device that helps to improve speech perception in noise and is considered the most beneficial approach to improve speech recognition in noise in cochlear implant users. According to guidelines, there is a need to perform a check before fitting the frequency modulation system. Although there are recommendations regarding the behavioral tests that should be performed at the fitting of the frequency modulation system to cochlear implant users, there are no published recommendations regarding the electroacoustic test that should be performed. Perform and determine the validity of an electroacoustic verification test for frequency modulation systems coupled to different cochlear implant speech processors. The sample included 40 participants between 5 and 18 year's users of four different models of speech processors. For the electroacoustic evaluation, we used the Audioscan Verifit device with the HA-1 coupler and the listening check devices corresponding to each speech processor model. In cases where the transparency was not achieved, a modification was made in the frequency modulation gain adjustment and we used the Brazilian version of the "Phrases in Noise Test" to evaluate the speech perception in competitive noise. It was observed that there was transparency between the frequency modulation system and the cochlear implant in 85% of the participants evaluated. After adjusting the gain of the frequency modulation receiver in the other participants, the devices showed transparency when the electroacoustic verification test was repeated. It was also observed that patients demonstrated better performance in speech perception in noise after a new adjustment, that is, in these cases; the electroacoustic transparency caused behavioral transparency. The electroacoustic evaluation protocol suggested was effective in evaluation of transparency between the frequency modulation system and the cochlear implant. Performing the adjustment of

  10. Effects on cuytoskeleton system in pollen tube of pinus thunbergii induced by ion beam implantation

    International Nuclear Information System (INIS)

    Huang Qunce; Liang Qiuxia; Li Guopin

    2008-01-01

    The damage of the cytoskeleton system in the pollen and the pollen tube of Pinus thunbergii induced by ion beam implantation were researched. The results showed that the disorganization of the micro-tubules in the pollen tube was produced by N + implantation. The abnormal states of the pollen tube in morphology were very correlative with the abnormality of the cytoskeleton system. N + implantation was responsible for morphological abnormalities in the pollen tubes. There was a distinct correlation between the damage effects and the ion implantation dose. The add of dose caused more obvious damage effects. Furthermore, the state of the cytoskeleton system in the pollen tube was influenced by the ion implantation. The impact grade depended also on the ion implantation dose. (authors)

  11. Finite element analysis of the stress distributions in peri-implant bone in modified and standard-threaded dental implants

    Directory of Open Access Journals (Sweden)

    Serkan Dundar

    2016-01-01

    Full Text Available The aim of this study was to examine the stress distributions with three different loads in two different geometric and threaded types of dental implants by finite element analysis. For this purpose, two different implant models, Nobel Replace and Nobel Active (Nobel Biocare, Zurich, Switzerland, which are currently used in clinical cases, were constructed by using ANSYS Workbench 12.1. The stress distributions on components of the implant system under three different static loadings were analysed for the two models. The maximum stress values that occurred in all components were observed in FIII (300 N. The maximum stress values occurred in FIII (300 N when the Nobel Replace implant is used, whereas the lowest ones, in the case of FI (150 N loading in the Nobel Active implant. In all models, the maximum tensions were observed to be in the neck region of the implants. Increasing the connection between the implant and the bone surface may allow more uniform distribution of the forces of the dental implant and may protect the bone around the implant. Thus, the implant could remain in the mouth for longer periods. Variable-thread tapered implants can increase the implant and bone contact.

  12. Processing of microCT implant-bone systems images using Fuzzy Mathematical Morphology

    International Nuclear Information System (INIS)

    Bouchet, A; Pastore, J; Colabella, L; Omar, S; Ballarre, J

    2016-01-01

    The relationship between a metallic implant and the existing bone in a surgical permanent prosthesis is of great importance since the fixation and osseointegration of the system leads to the failure or success of the surgery. Micro Computed Tomography is a technique that helps to visualize the structure of the bone. In this study, the microCT is used to analyze implant-bone systems images. However, one of the problems presented in the reconstruction of these images is the effect of the iron based implants, with a halo or fluorescence scattering distorting the micro CT image and leading to bad 3D reconstructions. In this work we introduce an automatic method for eliminate the effect of AISI 316L iron materials in the implant-bone system based on the application of Compensatory Fuzzy Mathematical Morphology for future investigate about the structural and mechanical properties of bone and cancellous materials. (paper)

  13. Stent implantation into the tracheo-bronchial system in rabbits: histopathologic sequelae in bare metal vs. drug-eluting stents.

    Science.gov (United States)

    Sigler, Matthias; Klötzer, Julia; Quentin, Thomas; Paul, Thomas; Möller, Oliver

    2015-12-01

    Stent implantation into the tracheo-bronchial system may be life-saving in selected pediatric patients with otherwise intractable stenosis of the upper airways. Following implantation, significant tissue proliferation may occur, requiring re-interventions. We sought to evaluate the effect of immunosuppressive coating of the stents on the extent of tissue proliferation in an animal model. Bare metal and sirolimus-coated stents (Bx Sonic and Cypher Select, Johnson & Johnson, Cordis) were implanted into non-stenotic lower airways of New Zealand white rabbits (weight 3.1 to 4.8 kg). Three stents with sirolimus coating and six bare metal stents could be analyzed by means of histology and immunohistochemistry 12 months after implantation. On a macroscopic evaluation, all stents were partially covered with a considerable amount of whitish tissue. Histologically, these proliferations contained fiber-rich connective tissue and some fibromuscular cells without significant differences between both stent types. The superficial tissue layer was formed by typical respiratory epithelium and polygonal cells. Abundant lymphocyte infiltrations and moderate granulocyte infiltrations were found in both groups correspondingly, whereas foreign-body reaction was more pronounced around sirolimus-eluting stents. After stent implantation in the tracheo-bronchial system of rabbits, we found tissue reactions comparable to those seen after stent implantation into the vascular system. There was no difference between coated and uncoated stents with regard to quality and quantity of tissue proliferation. We found, however, a significantly different inflammatory reaction with a more pronounced foreign-body reaction in sirolimus-coated stents. In our small series, drug-eluting stents did not exhibit any benefit over bare metal stents in an experimental setting.

  14. A Wireless Implantable Switched-Capacitor Based Optogenetic Stimulating System

    Science.gov (United States)

    Lee, Hyung-Min; Kwon, Ki-Yong; Li, Wen

    2015-01-01

    This paper presents a power-efficient implantable optogenetic interface using a wireless switched-capacitor based stimulating (SCS) system. The SCS efficiently charges storage capacitors directly from an inductive link and periodically discharges them into an array of micro-LEDs, providing high instantaneous power without affecting wireless link and system supply voltage. A custom-designed computer interface in LabVIEW environment wirelessly controls stimulation parameters through the inductive link, and an optrode array enables simultaneous neural recording along with optical stimulation. The 4-channel SCS system prototype has been implemented in a 0.35-μm CMOS process and combined with the optrode array. In vivo experiments involving light-induced local field potentials verified the efficacy of the SCS system. An implantable version of the SCS system with flexible hermetic sealing is under development for chronic experiments. PMID:25570099

  15. A classification of growth friendly spine implants.

    Science.gov (United States)

    Skaggs, David L; Akbarnia, Behrooz A; Flynn, John M; Myung, Karen S; Sponseller, Paul D; Vitale, Michael G

    2014-01-01

    Various types of spinal implants have been used with the objective of minimizing spinal deformities while maximizing the spine and thoracic growth in a growing child with a spinal deformity. The aim of this study was to describe a classification system of growth friendly spinal implants to allow researchers and clinicians to have a common language and facilitate comparative studies. Growth friendly spinal implant systems fall into 3 categories based upon the forces of correction the implants exert on the spine, which are as follows: Distraction-based systems correct spinal deformities by mechanically applying a distractive force across a deformed segment with anchors at the top and bottom of the implants, which commonly attach to the spine, rib, and/or the pelvis. The present examples of distraction-based implants are spine-based or rib-based growing rods, vertical expandable titanium rib prosthesis, and remotely expandable devices. Compression-based systems correct spinal deformities with a compressive force applied to the convexity of the curve causing convex growth inhibition. This compressive force may be generated both mechanically at the time of implantation, as well as over time resulting from longitudinal growth of vertebral endplates hindered by the spinal implants. Examples of compression-based systems are vertebral staples and tethers. Guided growth systems correct spinal deformity by anchoring multiple vertebrae (usually including the apical vertebrae) to rods with mechanical forces including translation at the time of the initial implant. The majority of the anchors are not rigidly attached to the rods, thus permitting longitudinal growth over time as the anchors slide over the rods. Examples of guided growth systems include the Luque trolley and Shilla. Each system has its benefits and shortcomings. Knowledge of the fundamental principles upon which these systems are based may aid the clinician to choose an appropriate treatment for patients. Having a

  16. Implantable electronics of a closed-loop system for controlling prosthetic hands

    Directory of Open Access Journals (Sweden)

    Nikas Antonios

    2017-09-01

    Full Text Available This paper presents the design of implantable electronics as a part of a system for prosthetic hand control. Purpose of the implant is the sensing of electrical signals originating from biological tissue and the actuation of the same, therefore closing the loop and allowing for an improved control of the prosthetic hand. The implant contains two integrated circuits for eight channel EMG monitoring and four channel stimulation, respectively. An on-board microcontroller allows for local pre-processing. All intracorporeal to extracorporeal communications are running through and are directed by the main processing platform. The external components of the control system include, in addition to the main processing and control platform, the inductive power transfer circuits and the pressure sensors for the sensory feedback. Different assembly and encapsulation options are taken into account for the implantable electronics and are unified in a single PCB design.

  17. Finite element analysis to compare complete denture and implant-retained overdentures with different attachment systems.

    Science.gov (United States)

    Barão, Valentim Adelino Ricardo; Assunção, Wirley Gonçalves; Tabata, Lucas Fernando; Delben, Juliana Aparecida; Gomes, Erica Alves; de Sousa, Edson Antonio Capello; Rocha, Eduardo Passos

    2009-07-01

    This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred in supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

  18. Do dual-thread orthodontic mini-implants improve bone/tissue mechanical retention?

    Science.gov (United States)

    Lin, Yang-Sung; Chang, Yau-Zen; Yu, Jian-Hong; Lin, Chun-Li

    2014-12-01

    The aim of this study was to understand whether the pitch relationship between micro and macro thread designs with a parametrical relationship in a dual-thread mini-implant can improve primary stability. Three types of mini-implants consisting of single-thread (ST) (0.75 mm pitch in whole length), dual-thread A (DTA) with double-start 0.375 mm pitch, and dual-thread B (DTB) with single-start 0.2 mm pitch in upper 2-mm micro thread region for performing insertion and pull-out testing. Histomorphometric analysis was performed in these specimens in evaluating peri-implant bone defects using a non-contact vision measuring system. The maximum inserted torque (Tmax) in type DTA was found to be the smallest significantly, but corresponding values found no significant difference between ST and DTB. The largest pull-out strength (Fmax) in the DTA mini-implant was found significantly greater than that for the ST mini-implant regardless of implant insertion orientation. Mini-implant engaged the cortical bone well as observed in ST and DTA types. Dual-thread mini-implant with correct micro thread pitch (parametrical relationship with macro thread pitch) in the cortical bone region can improve primary stability and enhanced mechanical retention.

  19. Cochlear Implantation in Patients with Neurofibromatosis Type 2 and Patients with Vestibular Schwannoma in the Only Hearing Ear

    Directory of Open Access Journals (Sweden)

    Erika Celis-Aguilar

    2012-01-01

    Full Text Available Cochlear implants are a new surgical option in the hearing rehabilitation of patients with neurofibromatosis type 2 (NF2 and patients with vestibular schwannoma (VS in the only hearing ear. Auditory brainstem implant (ABI has been the standard surgical treatment for these patients. We performed a literature review of patients with NF2 and patients with VS in the only hearing ear. Cochlear implantation (CI provided some auditory benefit in all patients. Preservation of cochlear nerve integrity is crucial after VS resection. Results ranged from environmental sound awareness to excellent benefit with telephone use. Promontory stimulation is recommended although not crucial. MRI can be performed safely in cochlear implanted patients.

  20. Placement of replace select Ti-Unite-coated type implants using a combination of immediate and submerge techniques after tooth extraction

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2006-06-01

    Full Text Available The high success rate of immediate implant placement both in the anterior and posterior regions were reported by many authors, therefore applying this techniques can be considered as a safe surgical procedure and minimizing the dental office visit for patient satisfaction. This paper reports the outcome of immediate placement of implants following extraction of anterior maxillary teeth. Combination technique of immediate and submerge implant placements including bone grafting procedure were used. Four implants with TiUnite surface type were placed immediately in two patients with the short-term result indicated that this technique may serve as a simple and safe procedure for immediate implant placement. It was concluded that immediate implant placement technique combined with TiUnite implant surface was successful in treating region directly after tooth extraction therefore this technique can be use as an alternative surgical method for dental implant rehabilitation.

  1. New orthopaedic implant management tool for computer-assisted planning, navigation, and simulation: from implant CAD files to a standardized XML-based implant database.

    Science.gov (United States)

    Sagbo, S; Blochaou, F; Langlotz, F; Vangenot, C; Nolte, L-P; Zheng, G

    2005-01-01

    Computer-Assisted Orthopaedic Surgery (CAOS) has made much progress over the last 10 years. Navigation systems have been recognized as important tools that help surgeons, and various such systems have been developed. A disadvantage of these systems is that they use non-standard formalisms and techniques. As a result, there are no standard concepts for implant and tool management or data formats to store information for use in 3D planning and navigation. We addressed these limitations and developed a practical and generic solution that offers benefits for surgeons, implant manufacturers, and CAS application developers. We developed a virtual implant database containing geometrical as well as calibration information for orthopedic implants and instruments, with a focus on trauma. This database has been successfully tested for various applications in the client/server mode. The implant information is not static, however, because manufacturers periodically revise their implants, resulting in the deletion of some implants and the introduction of new ones. Tracking these continuous changes and keeping CAS systems up to date is a tedious task if done manually. This leads to additional costs for system development, and some errors are inevitably generated due to the huge amount of information that has to be processed. To ease management with respect to implant life cycle, we developed a tool to assist end-users (surgeons, hospitals, CAS system providers, and implant manufacturers) in managing their implants. Our system can be used for pre-operative planning and intra-operative navigation, and also for any surgical simulation involving orthopedic implants. Currently, this tool allows addition of new implants, modification of existing ones, deletion of obsolete implants, export of a given implant, and also creation of backups. Our implant management system has been successfully tested in the laboratory with very promising results. It makes it possible to fill the current gap

  2. Implantable Medical Devices; Networking Security Survey

    Directory of Open Access Journals (Sweden)

    Siamak Aram

    2016-08-01

    Full Text Available The industry of implantable medical devices (IMDs is constantly evolving, which is dictated by the pressing need to comprehensively address new challenges in the healthcare field. Accordingly, IMDs are becoming more and more sophisticated. Not long ago, the range of IMDs’ technical capacities was expanded, making it possible to establish Internet connection in case of necessity and/or emergency situation for the patient. At the same time, while the web connectivity of today’s implantable devices is rather advanced, the issue of equipping the IMDs with sufficiently strong security system remains unresolved. In fact, IMDs have relatively weak security mechanisms which render them vulnerable to cyber-attacks that compromise the quality of IMDs’ functionalities. This study revolves around the security deficiencies inherent to three types of sensor-based medical devices; biosensors, insulin pump systems and implantable cardioverter defibrillators. Manufacturers of these devices should take into consideration that security and effectiveness of the functionality of implants is highly dependent on the design. In this paper, we present a comprehensive study of IMDs’ architecture and specifically investigate their vulnerabilities at networking interface.

  3. A Retrospective Analysis of Ruptured Breast Implants

    Directory of Open Access Journals (Sweden)

    Woo Yeol Baek

    2014-11-01

    Full Text Available BackgroundRupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants.MethodsWe performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone, duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management.ResultsForty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case, microfat graft (2 case, removal only (14 case, and follow-up loss (17 case.ConclusionsSaline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs.

  4. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    OpenAIRE

    Sanjay Byakodi; Sachin Kumar; Rajesh Kumar Reddy; Vipin Kumar; Shipra Sepolia; Shivangi Gupta; Harkanwal Preet Singh

    2017-01-01

    Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental i...

  5. Effects of ion implantation on charges in the silicon--silicon dioxide system

    International Nuclear Information System (INIS)

    Learn, A.J.; Hess, D.W.

    1977-01-01

    Structures consisting of thermally grown oxide on silicon were implanted with boron, arsenic, or argon ions. For argon implantation through oxides, an increased fixed oxide charge (Q/sub ss/) was observed with the increase being greater for than for silicon. This effect is attributed to oxygen recoil which produces additional excess ionized silicon in the oxide of a type similar to that arising in thermal oxidation. Fast surface state (N/sub st/) generation was also noted which in most cases obscured the Q/sub ss/ increase. Of various heat treatments tested, only a 900 degreeC anneal in hydrogen annihilated N/sub st/ and allowed Q/sub ss/ measurement. Such N/sub st/ apparently arises as a consequence of implantation damage at the silicon--silicon dioxide interface. With the exception of boron implantations into thick oxides or through aluminum electrodes, reduction of the mobile ionic charge (Q/sub o/) was achieved by implantation. The reduction again is presumably damage related and is not negated by high-temperature annealing but may be counterbalanced by aluminum incorporation in the oxide

  6. In Vitro Evaluation of Leakage at Implant-Abutment Connection of Three Implant Systems Having the Same Prosthetic Interface Using Rhodamine B

    Directory of Open Access Journals (Sweden)

    Antoine Berberi

    2014-01-01

    Full Text Available Objectives. Hollow space between implant and abutment may act as reservoir for commensal and/or pathogenic bacteria representing a potential source of tissue inflammation. Microbial colonization of the interfacial gap may ultimately lead to infection and bone resorption. Using Rhodamine B, a sensitive fluorescent tracer dye, we aim in this study to investigate leakage at implant-abutment connection of three implant systems having the same prosthetic interface. Materials and Methods. Twenty-one implants (seven Astra Tech, seven Euroteknika, and seven Dentium with the same prosthetic interface were connected to their original abutments, according to the manufacturers’ recommendation. After determination of the inner volume of each implant systems, the kinetic quantification of leakage was evaluated for each group using Rhodamine B (10−2 M. For each group, spectrophotometric analysis was performed to detect leakage with a fluorescence spectrophotometer at 1 h (T0 and 48 h (T1 of incubation time at room temperature. Results. Astra Tech had the highest inner volume (6.8 μL, compared to Dentium (4 μL and Euroteknika (2.9 μL. At T0 and T1, respectively, the leakage volume and percentage of each system were as follows: Astra Tech 0.043 μL or 1.48% (SD 0.0022, 0.08 μL or 5.56% (SD 0.0074, Euroteknika 0.09 μL or 6.93% (SD 0.0913, 0.21 μL or 20.55% (SD 0.0035, and Dentium 0.07 μL or 4.6% (SD 0.0029, 0.12 μL or 10.47% (SD 0.0072. Conclusion. The tested internal conical implant-abutment connections appear to be unable to prevent leakage. In average, Astra Tech implants showed the highest inner volume and the least leakage.

  7. Predicting the Failure of Dental Implants Using Supervised Learning Techniques

    Directory of Open Access Journals (Sweden)

    Chia-Hui Liu

    2018-05-01

    Full Text Available Prosthodontic treatment has been a crucial part of dental treatment for patients with full mouth rehabilitation. Dental implant surgeries that replace conventional dentures using titanium fixtures have become the top choice. However, because of the wide-ranging scope of implant surgeries, patients’ body conditions, surgeons’ experience, and the choice of implant system should be considered during treatment. The higher price charged by dental implant treatments compared to conventional dentures has led to a rush among medical staff; therefore, the future impact of surgeries has not been analyzed in detail, resulting in medial disputes. Previous literature on the success factors of dental implants is mainly focused on single factors such as patients’ systemic diseases, operation methods, or prosthesis types for statistical correlation significance analysis. This study developed a prediction model for providing an early warning mechanism to reduce the chances of dental implant failure. We collected the clinical data of patients who received artificial dental implants at the case hospital for a total of 8 categories and 20 variables. Supervised learning techniques such as decision tree (DT, support vector machines, logistic regressions, and classifier ensembles (i.e., Bagging and AdaBoost were used to analyze the prediction of the failure of dental implants. The results show that DT with both Bagging and Adaboost techniques possesses the highest prediction performance for the failure of dental implant (area under the receiver operating characteristic curve, AUC: 0.741; the analysis also revealed that the implant systems affect dental implant failure. The model can help clinical surgeons to reduce medical failures by choosing the optimal implant system and prosthodontics treatments for their patients.

  8. Systemic antibiotics and the risk of superinfection in peri-implantitis.

    Science.gov (United States)

    Verdugo, Fernando; Laksmana, Theresia; Uribarri, Agurne

    2016-04-01

    Peri-implantitis has emerged in the last few years as a complication difficult to resolve. The etiopathogenesis consensus is mainly attributed to bacteria. Following the preferred reporting items for systematic reviews and meta-analysis (PRISMA) guidelines, a PubMed/Medline literature search was performed using the US National Library of Medicine database up to 2015 to analyze available scientific data on the rationale and risk of superinfection associated to systemic antimicrobials in human peri-implant disease. A hand search was also conducted on relevant medical and microbiology journals. The methodological index for non-randomized studies (MINORS) was independently assessed for quality on the selected papers. Proposed combined therapies use broad-spectrum antibiotics to halt the disease progression. A major associated risk, particularly when prescribed empirically without microbiological follow-up, is the undetected development of superinfections and overgrowth of opportunistic pathogens difficult to eradicate. Peri-implant superinfections with opportunistic bacteria, yeast and viruses, are plausible risks associated to the use of systemic antibiotics in immunocompetent individuals. Lack of microbiological follow-up and antibiotic susceptibility testing may lead to ongoing microbial challenges that exacerbate the disease progression. The increased proliferation of antimicrobial resistance, modern implant surface topography and indiscriminative empiric antibiotic regimens may promote the escalation of peri-implant disease in years to come. A personalized 3-month supportive therapy may help prevent risks by sustaining a normal ecological balance, decreasing specific pathogen proportions and maintaining ideal plaque control. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments

    Science.gov (United States)

    Park, Ji-Man; Lee, Jai-Bong; Heo, Seong-Joo

    2014-01-01

    PURPOSE The aim of this study was to evaluate the interface accuracy of computer-assisted designed and manufactured (CAD/CAM) titanium abutments and implant fixture compared to gold-cast UCLA abutments. MATERIALS AND METHODS An external connection implant system (Mark III, n=10) and an internal connection implant system (Replace Select, n=10) were used, 5 of each group were connected to milled titanium abutment and the rest were connected to the gold-cast UCLA abutments. The implant fixture and abutment were tightened to torque of 35 Ncm using a digital torque gauge, and initial detorque values were measured 10 minutes after tightening. To mimic the mastication, a cyclic loading was applied at 14 Hz for one million cycles, with the stress amplitude range being within 0 N to 100 N. After the cyclic loading, detorque values were measured again. The fixture-abutment gaps were measured under a microscope and recorded with an accuracy of ±0.1 µm at 50 points. RESULTS Initial detorque values of milled abutment were significantly higher than those of cast abutment (P.05). After cyclic loading, detorque values of cast abutment increased, but those of milled abutment decreased (Pabutment group and the cast abutment group after cyclic loading. CONCLUSION In conclusion, CAD/CAM milled titanium abutment can be fabricated with sufficient accuracy to permit screw joint stability between abutment and fixture comparable to that of the traditional gold cast UCLA abutment. PMID:24605206

  10. Number of implants for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  11. [Researches on biomechanics of micro-implant-bone interface and optimum design of micro implant's neck].

    Science.gov (United States)

    Deng, Feng; Zhang, Lei; Zhang, Yi; Song, Jin-lin; Fan, Yuboa

    2007-07-01

    To compare and analyze the stress distribution at the micro-implant-bone interface based on the different micro-implant-bone conditioned under orthodontic load, and to optimize the design of micro implant's neck. An adult skull with all tooth was scanned by spiral CT, and the data were imported into computer for three-dimensional reconstruction with software Mimics 9.0. The three dimensional finite element models of three micro-implant-bone interfaces(initial stability, full osseointegration and fibrous integration) were analyzed by finite element analysis software ABAQUS6.5. The primary stress distributions of different micro-implant-bone conditions were evaluated when 2N force was loaded. Then the diameter less than 1.5 mm of the micro implant's neck was added with 0.2 mm, to compare the stress distribution of the modified micro-implant-bone interface with traditional type. The stress mostly concentrated on the neck of micro implant and the full osseointegration interface in all models showed the lowest strain level. Compared with the traditional type, the increasing diameter neck of the micro implant obviously decreased the stress level in all the three conditions. The micro-implant-bone interface and the diameter of micro implant's neck both are the important influence factors to the stress distribution of micro implant.

  12. Progress in ion implantation equipment for semiconductor manufacturing

    International Nuclear Information System (INIS)

    Kawai, Tadashi; Naito, Masao

    1987-01-01

    In the semiconductor device manufacturing industry, ion implantation systems are used to dope semiconductor substrates with impurities that act as donor or acceptor. In an ion implantation system, required impurity ions are generated from an ion source, subjected to mass analysis, accelerated, converged and implanted in semiconductor wafers. High-tension arc tends to cause troubles in these systems, but improvement in design increased the average operation rate of medium-power systems from bout 70 percent to 90 percent during the past 10 years. Freeman type ion sources have replaced most RF ion sources and cold cathode PIG sources, which had been widely used until the early 1970s. Many of the recent ion sources are equipped with a P and As vaporizer to increase the beam intensity. By an increased beam intensity or decreased handling time in combination with an automatic handling system, the throughput has reached 330 wafers per hour for 10 second implantation. The yield has increased due to the development of improved scanning methods, vacuum devices such as cryopump, and processes and apparatus that serve for preventing particles from being contained in micro-devices. Various other improvements have been made to permit efficient production. (Nogami, K.)

  13. Type IV Hypersensitivity to Gold Weight Upper-Eyelid Implant: Case Report and Review of the Literature.

    Science.gov (United States)

    Kilduff, Caroline L S; Casswell, Edward J; Imonikhe, Richard; Marjanovic, Branka

    2017-05-04

    Complications associated with gold-weight insertion for lagophthalmos are uncommon, recent reports have provided evidence to suggest that type IV hypersensitivity to gold can cause a persistent inflammatory reaction. We present a case of a 46-year-old man who experienced persistent post-operative inflammation, and summarize previously documented cases. This patient underwent uncomplicated insertion of an upper eyelid gold weight for right-sided facial nerve palsy. He had no allergies or implanted metalwork. Post-operatively erythema was noted at seven-weeks and did not resolve. The weight was removed after six-months. The histopathological findings were in keeping with type IV hypersensitivity and similar to previous cases. Although infrequent, this complication has poor outcomes. The definitive management is removal of the weight. Information regarding implanted gold, and previous reactions should be elicited pre-operatively. Type IV hypersensitivity should be considered in patients with persistent inflammation that do not respond to antibiotic or steroid therapy.

  14. Aspects of an automatic system of implants of radioactive seeds and anatomic object simulator for tests in prostate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Leonardo S.M.; Braga, Viviane V.B.; Campos, Tarcísio P. R. de, E-mail: leonardosantiago.lsms@gmail.com, E-mail: vitoriabraga06@gmail.com, E-mail: tprcampos@yahoo.com.br [Universidade Federal de Minas Gerais (PCTN/UFMG), Belo Horizonte (Brazil). Pós-Graduação em Ciências e Técnicas Nucleares. Departamento de Engenharia Nuclear

    2017-07-01

    This work presents the state of the art of the research and development of an automatic radioactive seed implantation system (PSIS). PSIS may assist in the procedure of testing permanent implants in the prostate. These tests will be important in measurements of absorbed doses in the pelvic structures, involving the organs and tissues at risk to improve planning, seed positioning and dosimetry. The automated Prostate Seed Implant System (PSIS) has been designed to meet operational needs, which offers the freedom of positioning of the brachytherapy needle within the treatment area and ensures repeatability and fidelity to the planned treatment. Both the ultrasound probe and the seed implant needle are driven by step motors, Atmega microcontroller, bearings, aluminum shafts and a GUI (Graphical User Interface). Movement of both the probe and the needle holder was performed by fixed spindle on a threaded rod rushing to the step motors by a coupling. The step motors used to move the system consist of step motors used in CNC (Computer Numeric Control) machine. The choice of these engines occurred due to the precision in the movements that can be obtained with these types of motors. The ultrasound probe serves to help, through the images acquired during the longitudinal movement, to monitor the application of the seeds. The parts that make up the system infrastructure were made of aluminum and translucent acrylic and cylindrical aluminum bars of different diameters. All these pieces were fixed and adjusted trough screws, washers, nuts and adhesive to metal, composing the final prototype of the PSIS. The project was developed and the PSIS prototype was assembled. The prototype presented acceptable operating characteristics for prostate implants. The advantage of this system is the automation of the application that provides an accurate positioning and movement of both probe and seed application. In addition to this study, seeds implantation tests will be performed, and

  15. Aspects of an automatic system of implants of radioactive seeds and anatomic object simulator for tests in prostate brachytherapy

    International Nuclear Information System (INIS)

    Silva, Leonardo S.M.; Braga, Viviane V.B.; Campos, Tarcísio P. R. de

    2017-01-01

    This work presents the state of the art of the research and development of an automatic radioactive seed implantation system (PSIS). PSIS may assist in the procedure of testing permanent implants in the prostate. These tests will be important in measurements of absorbed doses in the pelvic structures, involving the organs and tissues at risk to improve planning, seed positioning and dosimetry. The automated Prostate Seed Implant System (PSIS) has been designed to meet operational needs, which offers the freedom of positioning of the brachytherapy needle within the treatment area and ensures repeatability and fidelity to the planned treatment. Both the ultrasound probe and the seed implant needle are driven by step motors, Atmega microcontroller, bearings, aluminum shafts and a GUI (Graphical User Interface). Movement of both the probe and the needle holder was performed by fixed spindle on a threaded rod rushing to the step motors by a coupling. The step motors used to move the system consist of step motors used in CNC (Computer Numeric Control) machine. The choice of these engines occurred due to the precision in the movements that can be obtained with these types of motors. The ultrasound probe serves to help, through the images acquired during the longitudinal movement, to monitor the application of the seeds. The parts that make up the system infrastructure were made of aluminum and translucent acrylic and cylindrical aluminum bars of different diameters. All these pieces were fixed and adjusted trough screws, washers, nuts and adhesive to metal, composing the final prototype of the PSIS. The project was developed and the PSIS prototype was assembled. The prototype presented acceptable operating characteristics for prostate implants. The advantage of this system is the automation of the application that provides an accurate positioning and movement of both probe and seed application. In addition to this study, seeds implantation tests will be performed, and

  16. Y-type urethral duplication with rectal implantation of the urethra: Which is the best approach?

    Science.gov (United States)

    Macedo, Antonio; Ottoni, Sérgio Leite; Leal da Cruz, Marcela; Pompermaier, Jorge Antonio; Silva, Maria Isabel S; Liguori, Riberto; Garrone, Gilmar

    2018-02-01

    Y-type urethral duplication describes the condition in which a functional urethra is implanted in the rectum, and there is also a dysplastic topic urethra which produces mostly urinary dribbling. These patients are at risk of urinary tract complications and UTI. We aimed to present the surgical steps of a case treated by ASTRA approach in which we separated the urethra from the rectum and created a perineal urethrostomy. We treated a 5-month-old boy with Y-type (IIA-2) urethral duplication, in whom the orthotopic urethra was patent just in the penile segment. The patient had urinary flow per anus and minimal dribbling through the orthotopic urethra. We performed a combined cystoscopy with retrograde urethrogram and managed to catheterize the dysplastic urethra with a guide-wire that showed ectopic implantation in the prostatic urethra, below the bladder neck. We performed an ASTRA procedure to separate the urethra from the rectum. The urethral stump was further mobilized to the perineum and anastomosed to a perineal skin flap to create a stoma and minimize the risk of stricture. The patient was followed at 2 month-intervals, and at 6 months follow-up had an excellent outcome. The ASTRA approach proved to be an excellent alternative for Y-type urethral duplication with functional urethra implanted in the rectum. We believe that further efforts to reconstruct the urethra should be avoided, with a better and simpler option being to create a definitive perineal urethrostomy. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  17. The Pathology of Orthopedic Implant Failure Is Mediated by Innate Immune System Cytokines

    Directory of Open Access Journals (Sweden)

    Stefan Landgraeber

    2014-01-01

    Full Text Available All of the over 1 million total joint replacements implanted in the US each year are expected to eventually fail after 15–25 years of use, due to slow progressive subtle inflammation at the bone implant interface. This inflammatory disease state is caused by implant debris acting, primarily, on innate immune cells, that is, macrophages. This slow progressive pathological bone loss or “aseptic loosening” is a potentially life-threatening condition due to the serious complications in older people (>75 yrs of total joint replacement revision surgery. In some people implant debris (particles and ions from metals can influence the adaptive immune system as well, giving rise to the concept of metal sensitivity. However, a consensus of studies agrees that the dominant form of this response is due to innate reactivity by macrophages to implant debris where both danger (DAMP and pathogen (PAMP signalling elicit cytokine-based inflammatory responses. This paper discusses implant debris induced release of the cytokines and chemokines due to activation of the innate (and the adaptive immune system and the subsequent formation of osteolysis. Different mechanisms of implant-debris reactivity related to the innate immune system are detailed, for example, danger signalling (e.g., IL-1β, IL-18, IL-33, etc., toll-like receptor activation (e.g., IL-6, TNF-α, etc., apoptosis (e.g., caspases 3–9, bone catabolism (e.g., TRAP5b, and hypoxia responses (Hif1-α. Cytokine-based clinical and basic science studies are in progress to provide diagnosis and therapeutic intervention strategies.

  18. The Pathology of Orthopedic Implant Failure Is Mediated by Innate Immune System Cytokines

    Science.gov (United States)

    Landgraeber, Stefan; Jäger, Marcus; Jacobs, Joshua J.; Hallab, Nadim James

    2014-01-01

    All of the over 1 million total joint replacements implanted in the US each year are expected to eventually fail after 15–25 years of use, due to slow progressive subtle inflammation at the bone implant interface. This inflammatory disease state is caused by implant debris acting, primarily, on innate immune cells, that is, macrophages. This slow progressive pathological bone loss or “aseptic loosening” is a potentially life-threatening condition due to the serious complications in older people (>75 yrs) of total joint replacement revision surgery. In some people implant debris (particles and ions from metals) can influence the adaptive immune system as well, giving rise to the concept of metal sensitivity. However, a consensus of studies agrees that the dominant form of this response is due to innate reactivity by macrophages to implant debris where both danger (DAMP) and pathogen (PAMP) signalling elicit cytokine-based inflammatory responses. This paper discusses implant debris induced release of the cytokines and chemokines due to activation of the innate (and the adaptive) immune system and the subsequent formation of osteolysis. Different mechanisms of implant-debris reactivity related to the innate immune system are detailed, for example, danger signalling (e.g., IL-1β, IL-18, IL-33, etc.), toll-like receptor activation (e.g., IL-6, TNF-α, etc.), apoptosis (e.g., caspases 3–9), bone catabolism (e.g., TRAP5b), and hypoxia responses (Hif1-α). Cytokine-based clinical and basic science studies are in progress to provide diagnosis and therapeutic intervention strategies. PMID:24891761

  19. Effect of Abutment Modification and Cement Type on Retention of Cement-Retained Implant Supported Crowns

    Science.gov (United States)

    Farzin, Mitra; Torabi, Kianoosh; Ahangari, Ahmad Hasan; Derafshi, Reza

    2014-01-01

    Objective: Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.The purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations. Materials and Method: Two prefabricated abutments were attached to their corresponding analogs and embedded in an acrylic resin block. The first abutment (control group) was left intact without any modifications. The screw access channel for the first abutment was completely filled with composite resin. In the second abutment, (test group) the axial wall was partially removed to form an abutment with 3 walls. Wax models were made by CAD/CAM. Ten cast copings were fabricated for each abutment. The prepared copings were cemented on the abutments by Temp Bond luting agent under standardized conditions (n=20). The assemblies were stored in 100% humidity for one day at 37°C prior to testing. The cast crown was removed from the abutment using an Instron machine, and the peak removal force was recorded. Coping/abutment specimens were cleaned after testing, and the testing procedure was repeated for Dycal luting agent (n=20). Data were analyzed with two- way ANOVA (α=0.05). Results: There was no significant difference in the mean transformed retention (Ln-R) between intact abutments (4.90±0.37) and the abutments with 3 walls (4.83±0.25) using Dycal luting agent. However, in TempBond group, the mean transformed retention (Ln-R) was significantly lower in the intact abutment (3.9±0.23) compared to the abutment with 3 walls (4.13±0.33, P=0.027). Conclusion: The retention of cement-retained implant restoration can be improved by the type of temporary cement used. The retention of cast crowns cemented to implant abutments with TempBond is influenced by the wall removal. PMID:25628660

  20. Effect of abutment modification and cement type on retention of cement-retained implant supported crowns.

    Directory of Open Access Journals (Sweden)

    Mitra Farzin

    2014-06-01

    Full Text Available Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.The purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations.Two prefabricated abutments were attached to their corresponding analogs and embedded in an acrylic resin block. The first abutment (control group was left intact without any modifications. The screw access channel for the first abutment was completely filled with composite resin. In the second abutment, (test group the axial wall was partially removed to form an abutment with 3 walls. Wax models were made by CAD/CAM. Ten cast copings were fabricated for each abutment. The prepared copings were cemented on the abutments by Temp Bond luting agent under standardized conditions (n=20. The assemblies were stored in 100% humidity for one day at 37°C prior to testing. The cast crown was removed from the abutment using an Instron machine, and the peak removal force was recorded. Coping/abutment specimens were cleaned after testing, and the testing procedure was repeated for Dycal luting agent (n=20. Data were analyzed with two- way ANOVA (α=0.05.There was no significant difference in the mean transformed retention (Ln-R between intact abutments (4.90±0.37 and the abutments with 3 walls (4.83±0.25 using Dycal luting agent. However, in TempBond group, the mean transformed retention (Ln-R was significantly lower in the intact abutment (3.9±0.23 compared to the abutment with 3 walls (4.13±0.33, P=0.027.The retention of cement-retained implant restoration can be improved by the type of temporary cement used. The retention of cast crowns cemented to implant abutments with TempBond is influenced by the wall removal.

  1. Trends in funding, internationalization, and types of study for original articles published in five implant-related journals between 2005 and 2009.

    Science.gov (United States)

    Barão, Valentim Adelino Ricardo; Shyamsunder, Nodesh; Yuan, Judy Chia-Chun; Knoernschild, Kent L; Assunção, Wirley Gonçalves; Sukotjo, Cortino

    2012-01-01

    The aims of this study were to evaluate the trends in funding, geographic origin, and study types of original articles in the dental implant literature and to investigate the relationships among these factors. Articles published in Clinical Oral Implants Research, The International Journal of Oral and Maxillofacial Implants, Clinical Implant Dentistry and Related Research, Implant Dentistry, and Journal of Oral Implantology from 2005 to 2009 were reviewed. Nonoriginal articles were excluded. For each article included, extramural funding source, geographic origin, and study type were recorded. Descriptive and analytic analyses (α = .05), including a logistic regression analysis, and chi-square test were used where appropriate. Of a total of 2,085 articles published, 1,503 met the inclusion criteria. The most common source of funding was from industry (32.4%). The proportion of studies that reported funding increased significantly over time. Europe represented the highest percentage (55.8%) of published articles. Most of the articles reported on clinical studies (49.9%), followed by animal studies (25.9%). Articles from Asia and South America and animal and in vitro studies were significantly more likely to be funded. Almost half of the original dental implant articles were funded. The trend toward internationalization of authorship was evident. A strong association was observed between funding and geographic origin and between funding and study type. Most studies in North America and Europe were clinical studies and supported by industry, whereas a greater proportion of studies in Asia and South America were in vitro or animal studies funded through government resources.

  2. Effects of pore size, implantation time, and nano-surface properties on rat skin ingrowth into percutaneous porous titanium implants.

    Science.gov (United States)

    Farrell, Brad J; Prilutsky, Boris I; Ritter, Jana M; Kelley, Sean; Popat, Ketul; Pitkin, Mark

    2014-05-01

    The main problem of percutaneous osseointegrated implants is poor skin-implant integration, which may cause infection. This study investigated the effects of pore size (Small, 40-100 μm and Large, 100-160 μm), nanotubular surface treatment (Nano), and duration of implantation (3 and 6 weeks) on skin ingrowth into porous titanium. Each implant type was percutaneously inserted in the back of 35 rats randomly assigned to seven groups. Implant extrusion rate was measured weekly and skin ingrowth into implants was determined histologically after harvesting implants. It was found that all three types of implants demonstrated skin tissue ingrowth of over 30% (at week 3) and 50% (at weeks 4-6) of total implant porous area under the skin; longer implantation resulted in greater skin ingrowth (p skin integration with the potential for a safe seal. Copyright © 2013 Wiley Periodicals, Inc.

  3. Dental-Implantate und ihre Werkstoffe

    Science.gov (United States)

    Newesely, Heinrich

    1983-07-01

    Some new trends in materials for dental implants, which also effect in the operative techniques and implant design, are described. Advantages and shortcomings of the different material types are exemplified and correlated with their bioinert resp. bioactive functions. The practical interest in metallic implants focussed in titanium resp. oxide ceramics in the ceramic field, whereas the special goal of implant research follows from the improvement of the bioactive principle with loaded calcium phosphate implants.

  4. Regular and platform switching: bone stress analysis varying implant type.

    Science.gov (United States)

    Gurgel-Juarez, Nália Cecília; de Almeida, Erika Oliveira; Rocha, Eduardo Passos; Freitas, Amílcar Chagas; Anchieta, Rodolfo Bruniera; de Vargas, Luis Carlos Merçon; Kina, Sidney; França, Fabiana Mantovani Gomes

    2012-04-01

    This study aimed to evaluate stress distribution on peri-implant bone simulating the influence of platform switching in external and internal hexagon implants using three-dimensional finite element analysis. Four mathematical models of a central incisor supported by an implant were created: External Regular model (ER) with 5.0 mm × 11.5 mm external hexagon implant and 5.0 mm abutment (0% abutment shifting), Internal Regular model (IR) with 4.5 mm × 11.5 mm internal hexagon implant and 4.5 mm abutment (0% abutment shifting), External Switching model (ES) with 5.0 mm × 11.5 mm external hexagon implant and 4.1 mm abutment (18% abutment shifting), and Internal Switching model (IS) with 4.5 mm × 11.5 mm internal hexagon implant and 3.8 mm abutment (15% abutment shifting). The models were created by SolidWorks software. The numerical analysis was performed using ANSYS Workbench. Oblique forces (100 N) were applied to the palatal surface of the central incisor. The maximum (σ(max)) and minimum (σ(min)) principal stress, equivalent von Mises stress (σ(vM)), and maximum principal elastic strain (ε(max)) values were evaluated for the cortical and trabecular bone. For cortical bone, the highest stress values (σ(max) and σ(vm) ) (MPa) were observed in IR (87.4 and 82.3), followed by IS (83.3 and 72.4), ER (82 and 65.1), and ES (56.7 and 51.6). For ε(max), IR showed the highest stress (5.46e-003), followed by IS (5.23e-003), ER (5.22e-003), and ES (3.67e-003). For the trabecular bone, the highest stress values (σ(max)) (MPa) were observed in ER (12.5), followed by IS (12), ES (11.9), and IR (4.95). For σ(vM), the highest stress values (MPa) were observed in IS (9.65), followed by ER (9.3), ES (8.61), and IR (5.62). For ε(max) , ER showed the highest stress (5.5e-003), followed by ES (5.43e-003), IS (3.75e-003), and IR (3.15e-003). The influence of platform switching was more evident for cortical bone than for trabecular bone, mainly for the external hexagon

  5. The Failure Envelope Concept Applied To The Bone-Dental Implant System.

    Science.gov (United States)

    Korabi, R; Shemtov-Yona, K; Dorogoy, A; Rittel, D

    2017-05-17

    Dental implants interact with the jawbone through their common interface. While the implant is an inert structure, the jawbone is a living one that reacts to mechanical stimuli. Setting aside mechanical failure considerations of the implant, the bone is the main component to be addressed. With most failure criteria being expressed in terms of stress or strain values, their fulfillment can mean structural flow or fracture. However, in addition to those effects, the bony structure is likely to react biologically to the applied loads by dissolution or remodeling, so that additional (strain-based) criteria must be taken into account. While the literature abounds in studies of particular loading configurations, e.g. angle and value of the applied load to the implant, a general study of the admissible implant loads is still missing. This paper introduces the concept of failure envelopes for the dental implant-jawbone system, thereby defining admissible combinations of vertical and lateral loads for various failure criteria of the jawbone. Those envelopes are compared in terms of conservatism, thereby providing a systematic comparison of the various failure criteria and their determination of the admissible loads.

  6. Accuracy of a digital impression system based on parallel confocal laser technology for implants with consideration of operator experience and implant angulation and depth.

    Science.gov (United States)

    Giménez, Beatriz; Özcan, Mutlu; Martínez-Rus, Francisco; Pradíes, Guillermo

    2014-01-01

    To evaluate the accuracy of a digital impression system based on parallel confocal red laser technology, taking into consideration clinical parameters such as operator experience and angulation and depth of implants. A maxillary master model with six implants (located bilaterally in the second molar, second premolar, and lateral incisor positions) was fitted with six polyether ether ketone scan bodies. One second premolar implant was placed with 30 degrees of mesial angulation; the opposite implant was positioned with 30 degrees of distal angulation. The lateral incisor implants were placed 2 or 4 mm subgingivally. Two experienced and two inexperienced operators performed intraoral scanning. Five different interimplant distances were then measured. The files obtained from the scans were imported with reverse-engineering software. Measurements were then made with a coordinate measurement machine, with values from the master model used as reference values. The deviations from the actual values were then calculated. The differences between experienced and inexperienced operators and the effects of different implant angulations and depths were compared statistically. Overall, operator 3 obtained significantly less accurate results. The angulated implants did not significantly influence accuracy compared to the parallel implants. Differences were found in the amount of error in the different quadrants. The second scanned quadrant had significantly worse results than the first scanned quadrant. Impressions of the implants placed at the tissue level were less accurate than implants placed 2 and 4 mm subgingivally. The operator affected the accuracy of measurements, but the performance of the operator was not necessarily dependent on experience. Angulated implants did not decrease the accuracy of the digital impression system tested. The scanned distance affected the predictability of the accuracy of the scanner, and the error increased with the increased length of the

  7. Botulinum Toxin Type A as Preoperative Treatment for Immediately Loaded Dental Implants Placed in Fresh Extraction Sockets for Full-Arch Restoration of Patients With Bruxism.

    Science.gov (United States)

    Mijiritsky, Eitan; Mortellaro, Carmen; Rudberg, Omri; Fahn, Miri; Basegmez, Cansu; Levin, Liran

    2016-05-01

    The aim of the present report was to describe the use of Botulinum toxin type A as preoperative treatment for immediately loaded dental implants placed in fresh extraction sockets for full-arch restoration of patients with bruxism. Patients with bruxism who were scheduled to receive immediately loaded full-arch implant supported fixed restorations were included in this retrospective clinical report. To reduce the occlusal forces applied in patients with bruxism, Botulinum toxin type A was introduced prior to the implant placement procedure. Patients were followed and implant survival as well as peri-implant bone level was assessed in each periodic follow-up visit. Adverse effects were also recorded. A control group with no use of Botulinum toxin was evaluated as well. A total of 26 patients (13 test and 13 control), with bruxism, aged 59.15 ± 11.43 years on average were included in this retrospective report and received immediately loaded dental implants placed in fresh extraction sockets for full-arch restoration. The test group treatment preceded by Botulinum toxin type A injection. Maxillary arches were supported by 8 to 10 implants while the mandibular arch was supported by 6 implants. All surgeries went uneventfully and no adverse effects were observed. The average follow-up time was 32.5 ± 10.4 months (range, 18-51). In the test group, no implant failures were recorded. One patient presented with 1 to 2 mm bone loss around 4 of the implants; the other implants presented with stable bone level. In the control group 1 patient lost 2 implants and another demonstrated 2 mm bone loss around 3 of the implants. The preoperative use of Botulinum toxin in patients with bruxism undergoing full-arch rehabilitation using immediately loaded dental implants placed in fresh extraction sockets seems to be a technique that deserves attention. Further long-term, large-scale randomized clinical trials will help to determine the additional benefit of this suggested

  8. Quality assurance: recommended guidelines for safe heating by capacitive-type heating technique to treat patients with metallic implants.

    Science.gov (United States)

    Kato, Hirokazu; Kondo, Motoharu; Imada, Hajime; Kuroda, Masahiro; Kamimura, Yoshitsugu; Saito, Kazuyuki; Kuroda, Kagayaki; Ito, Koichi; Takahashi, Hideaki; Matsuki, Hidetoshi

    2013-05-01

    This article is a redissemination of the previous Japanese Quality Assurance Guide guidelines. Specific absorption rate and temperature distribution were investigated with respect to various aspects including metallic implant size and shape, insertion site, insertion direction, blood flow and heating power, and simulated results were compared with adverse reactions of patients treated by radio frequency capacitive-type heating. Recommended guidelines for safe heating methods for patients with metallic implants are presented based on our findings.

  9. Implementation and validation of an implant-based coordinate system for RSA migration calculation.

    Science.gov (United States)

    Laende, Elise K; Deluzio, Kevin J; Hennigar, Allan W; Dunbar, Michael J

    2009-10-16

    An in vitro radiostereometric analysis (RSA) phantom study of a total knee replacement was carried out to evaluate the effect of implementing two new modifications to the conventional RSA procedure: (i) adding a landmark of the tibial component as an implant marker and (ii) defining an implant-based coordinate system constructed from implant landmarks for the calculation of migration results. The motivation for these two modifications were (i) to improve the representation of the implant by the markers by including the stem tip marker which increases the marker distribution (ii) to recover clinical RSA study cases with insufficient numbers of markers visible in the implant polyethylene and (iii) to eliminate errors in migration calculations due to misalignment of the anatomical axes with the RSA global coordinate system. The translational and rotational phantom studies showed no loss of accuracy with the two new measurement methods. The RSA system employing these methods has a precision of better than 0.05 mm for translations and 0.03 degrees for rotations, and an accuracy of 0.05 mm for translations and 0.15 degrees for rotations. These results indicate that the new methods to improve the interpretability, relevance, and standardization of the results do not compromise precision and accuracy, and are suitable for application to clinical data.

  10. Ventricular fibrillation induced by coagulating mode bipolar electrocautery during pacemaker implantation in Myotonic Dystrophy type 1 patient.

    Science.gov (United States)

    Russo, Vincenzo; Rago, Anna; DI Meo, Federica; Cioppa, Nadia Della; Papa, Andrea Antonio; Russo, Maria Giovanna; Nigro, Gerardo

    2014-12-01

    The occurrence of ventricular fibrillation, induced by bipolar electrocautery during elective dual chamber pacemaker implantation, is reported in a patient affected by Myotonic Distrophy type 1 with normal left ventricular ejection fraction.

  11. In Vitro Laser Treatment Platform Construction with Dental Implant Thread Surface on Bacterial Adhesion for Peri-Implantitis

    Directory of Open Access Journals (Sweden)

    Hsien-Nan Kuo

    2017-01-01

    Full Text Available This study constructs a standard in vitro laser treatment platform with dental implant thread surface on bacterial adhesion for peri-implantitis at different tooth positions. The standard clinical adult tooth jaw model was scanned to construct the digital model with 6 mm bone loss depth on behalf of serious peri-implantitis at the incisor, first premolar, and first molar. A cylindrical suite connected to the implant and each tooth root in the jaw model was designed as one experimental unit set to allow the suite to be replaced for individual bacterial adhesion. The digital peri-implantitis and suite models were exported to fulfill the physical model using ABS material in a 3D printer. A 3 mm diameter specimen implant on bacterial adhesion against Escherichia coli was performed for gram-negative bacteria. An Er:YAG laser, working with a chisel type glass tip, was moved from the buccal across the implant thread to the lingual for about 30 seconds per sample to verify the in vitro laser treatment platform. The result showed that the sterilization rate can reach 99.3% and the jaw model was not damaged after laser irradiation testing. This study concluded that using integrated image processing, reverse engineering, CAD system, and a 3D printer to construct a peri-implantitis model replacing the implant on bacterial adhesion and acceptable sterilization rate proved the feasibility of the proposed laser treatment platform.

  12. Microscopic evaluation of implant platform adaptation with UCLA-type abutments: in vitro study

    Directory of Open Access Journals (Sweden)

    Vinícius Anéas RODRIGUES

    Full Text Available Abstract Introduction The fit between abutment and implant is crucial to determine the longevity of implant-supported prostheses and the maintenance of peri-implant bones. Objective To evaluate the vertical misfit between different abutments in order to provide information to assist abutment selection. Material and method UCLA components (N=40 with anti-rotational system were divided as follows: components usinated in titanium (n=10 and plastic components cast proportionally in titanium (n=10, nickel-chromium-titanium-molybdenum (n=10 and nickel-chromium (n=10 alloys. All components were submitted to stereomicroscope analysis and were randomly selected for characterization by SEM. Result Data were analyzed using mean and standard deviation and subjected to ANOVA-one way, where the groups proved to statistically different (p=<0.05, followed by Tukey’s test. Conclusion The selection of material influences the value of vertical misfit. The group machined in Ti showed the lowest value while the group cast in Ni Cr showed the highest value of vertical misfit.

  13. A study of vacancy-type defects in B+-implanted SiO2/Si by a slow positron beam

    International Nuclear Information System (INIS)

    Uedono, Akira; Tanigawa, Shoichiro; Sugiura, Jun; Ogasawara, Makoto.

    1989-01-01

    Variable-energy (0∼30 keV) positron beam studies have been carried out on 80 keV B + -implanted SiO 2 (43 nm)/Si specimens. Doppler broadening profiles of the positron annihilation as a function of the incident positron energy were shown to be quite sensitive for the detection of vacancy-type defects introduced by B + -implantation. The average depth of the defected regions was found to shift towards the surface of the specimen with increasing the dose of B + ions. This effect is attributed to the accumulation of vacancy-type defects at the SiO 2 /Si interface. Dominant defect species were identified as vacancy clusters by their annealing stage. (author)

  14. Composite fibrous glaucoma drainage implant

    Science.gov (United States)

    Klapstova, A.; Horakova, J.; Shynkarenko, A.; Lukas, D.

    2017-10-01

    Glaucoma is a frequent reason of loss vision. It is usually caused by increased intraocular pressure leading to damage of optic nerve head. This work deals with the development of fibrous structure suitable for glaucoma drainage implants (GDI). Commercially produced metallic glaucoma implants are very effective in lowering intraocular pressure. However, these implants may cause adverse events such as damage to adjacent tissue, fibrosis, hypotony or many others [1]. The aim of this study is to reduce undesirable properties of currently produced drains and improve their properties by creating of the composite fibrous drain for achieve a normal intraocular pressure. Two types of electrospinning technologies were used for the production of very small tubular implants. First type was focused for production of outer part of tubular drain and the second type of electrospinning method made the inner part of shape follows the connections of both parts. Complete implant had a special properties suitable for drainage of fluid. Morphological parameters, liquid transport tests and in-vitro cell adhesion tests were detected.

  15. Wireless patient monitoring system for a moving-actuator type artificial heart.

    Science.gov (United States)

    Nam, K W; Chung, J; Choi, S W; Sun, K; Min, B G

    2006-10-01

    In this study, we developed a wireless monitoring system for outpatients equipped with a moving-actuator type pulsatile bi-ventricular assist device, AnyHeart. The developed monitoring system consists of two parts; a Bluetooth-based short-distance self-monitoring system that can monitor and control the operating status of a VAD using a Bluetooth-embedded personal digital assistant or a personal computer within a distance of 10 meters, and a cellular network-based remote monitoring system that can continuously monitor and control the operating status of AnyHeart at any location. Results of in vitro experiments demonstrate the developed system's ability to monitor the operational status of an implanted AnyHeart.

  16. Risk factors and periimplantitis in implant therapy. Narrative review

    Directory of Open Access Journals (Sweden)

    Francis Bravo

    2013-12-01

    Full Text Available Diseases involving tissue around the teeth and osseointegrated implants are the result of an interaction between some type of pathological agent (bacterial, viral, etc. and host immune response. These interactions can occur both in the dental tissues as those biomaterials which are introduced to attempt to correct some type of periodontal disease, the implant being a biocompatible substitute of the teeth is not free from this type of interaction often enrolled periodontal and peri-implant pathology. The peri-implantitis is a type of disease that results from this interaction, the risk factors and risk indicators of peri-implantitis are broad and complex. This article summarizes the multiple sources of information in the scientific literature to address in detail the aspects of the main risk factors and the peri-implantitis in the peri implant therapy.

  17. High-energy ion implantation of materials

    International Nuclear Information System (INIS)

    Williams, J.M.

    1991-11-01

    High-energy ion implantation is an extremely flexible type of surface treatment technique, in that it offers the possibility of treating almost any type of target material or product with ions of almost any chemical species, or combinations of chemical species. In addition, ion implantations can be combined with variations in temperature during or after ion implantation. As a result, the possibility of approaching a wide variety of surface-related materials science problems exists with ion implantation. This paper will outline factors pertinent to application of high-energy ion implantation to surface engineering problems. This factors include fundamental advantages and limitations, economic considerations, present and future equipment, and aspects of materials science

  18. Al and Cu Implantation into Silicon Substrate for Ohmic Contact in Solar Cell Fabrication

    International Nuclear Information System (INIS)

    Sri Sulamdari; Sudjatmoko; Wirjoadi; Yunanto; Bambang Siswanto

    2002-01-01

    Research on the implantation of Al and Cu ions into silicon substrate for ohmic contact in solar cell fabrication has been carried using ion accelerator machine. Al and Cu ions are from 98% Al and 99.9% Cu powder ionized in ion source system. provided in ion implantor machine. Before implantation process, (0.5 x 1) cm 2 N type and P type silicon were washed in water and then etched in Cp-4A solution. After that, P type silicon were implanted with Al ions and N type silicon were implanted with Cu ions with the ions dose from 10 13 ion/cm 2 - 10 16 ion/cm 2 and energy 20 keV - 80 keV. Implanted samples were then annealed at temperature 400 o C - 850 o C. Implanted and annealed samples were characterized their resistivities using four point probe FPP-5000. It was found that at full electrically active conditions the ρ s for N type was 1.30 x 10 8 Ω/sq, this was achieved at ion dose 10 13 ion/cm 2 and annealing temperature 500 o C. While for P type, the ρ s was 1.13 x 10 2 Ω/sq, this was achieved at ion dose 10 13 ion/cm 2 and energy 40 keV, and annealing temperature 500 o C. (author)

  19. Cutaneous and systemic hypersensitivity reactions to metallic implants

    DEFF Research Database (Denmark)

    Basko-Plluska, Juliana L; Thyssen, Jacob P; Schalock, Peter C

    2011-01-01

    Cutaneous reactions to metal implants, orthopedic or otherwise, are well documented in the literature. The first case of a dermatitis reaction over a stainless steel fracture plate was described in 1966. Most skin reactions are eczematous and allergic in nature, although urticarial, bullous....... However, other metal ions as well as bone cement components can cause such hypersensitivity reactions. To complicate things, patients may also develop delayed-type hypersensitivity reactions to metals (ie, in-stent restenosis, prosthesis loosening, inflammation, pain, or allergic contact dermatitis...

  20. Electrophysiology Catheter-Facilitated coronary sinus cannulation and implantation of cardiac resynchronization therapy systems

    Directory of Open Access Journals (Sweden)

    Antonis S. Manolis, MD, FESC, FACC, FHRS

    2018-01-01

    Full Text Available Background: Cardiac resynchronization therapy (CRT device implantation is hampered by difficult placement of the left ventricular (LV lead. We have routinely used a steerable electrophysiology catheter to guide coronary sinus (CS cannulation and facilitate LV lead positioning. The aim of this prospective study is to present our results with this approach in 138 consecutive patients receiving a CRT device over 10 years. Methods: The study included 120 men and 18 women, aged 64.8±11.4 years, with coronary disease (n=63, cardiomyopathy (n=72, or other disease (n=3, and mean ejection fraction of 24.5±4.5%. Devices were implanted for refractory heart failure and dyssynchrony, all but 2 in the presence of left bundle branch block. Implanted devices included biventricular pacemakers (CRT-P (n=33 and cardioverter defibrillators (CRT-D (n=105. Results: Using the electrophysiology catheter, the CS could be engaged in 134 (97.1% patients. In 4 patients failing CS cannulation, a dual-chamber device was implanted in 2, and bifocal right ventricular pacing was effected in 2. Bifocal (n=2 or conventional (n=1 systems were implanted in another 3 patients, in whom the LV lead got dislodged (n=2 or removed because of local dissection (n=1. Thus, finally, a CRT system was successfully established in 131 (94.9% patients. There were 3 patients with CS dissection, of whom 1 was complicated by cardiac tamponade managed with pericardiocentesis. There were no perioperative deaths. During follow-up (31.0±21.2 months, clinical improvement was reported by 108 (82.4% patients. Conclusion: Routine use of an electrophysiology catheter greatly facilitated CS cannulation and successful LV lead placement in ∼95% of patients undergoing CRT system implantation. Keywords: heart failure, cardiac resynchronization therapy, implantable cardioverter defibrillator, coronary sinus, left ventricular lead

  1. Percutaneous and skeletal biocarbon implants

    Science.gov (United States)

    Mooney, V.

    1977-01-01

    Review of carbon implants developed by NASA discussed four different types of implants and subsequent improvements. Improvements could be of specific interest to rehabilitation centers and similar organizations.

  2. Bioelectric analyses of an osseointegrated intelligent implant design system for amputees.

    Science.gov (United States)

    Isaacson, Brad M; Stinstra, Jeroen G; MacLeod, Rob S; Webster, Joseph B; Beck, James P; Bloebaum, Roy D

    2009-07-15

    The projected number of American amputees is expected to rise to 3.6 million by 2050. Many of these individuals depend on artificial limbs to perform routine activities, but prosthetic suspensions using traditional socket technology can prove to be cumbersome and uncomfortable for a person with limb loss. Moreover, for those with high proximal amputations, limited residual limb length may prevent exoprosthesis attachment all together. Osseointegrated implant technology is a novel operative procedure which allows firm skeletal attachment between the host bone and an implant. Preliminary results in European amputees with osseointegrated implants have shown improved clinical outcomes by allowing direct transfer of loads to the bone-implant interface. Despite the apparent advantages of osseointegration over socket technology, the current rehabilitation procedures require long periods of restrictive load bearing prior which may be reduced with expedited skeletal attachment via electrical stimulation. The goal of the osseointegrated intelligent implant design (OIID) system is to make the implant part of an electrical system to accelerate skeletal attachment and help prevent periprosthetic infection. To determine optimal electrode size and placement, we initiated proof of concept with computational modeling of the electric fields and current densities that arise during electrical stimulation of amputee residual limbs. In order to provide insure patient safety, subjects with retrospective computed tomography scans were selected and three dimensional reconstructions were created using customized software programs to ensure anatomical accuracy (Seg3D and SCIRun) in an IRB and HIPAA approved study. These software packages supported the development of patient specific models and allowed for interactive manipulation of electrode position and size. Preliminary results indicate that electric fields and current densities can be generated at the implant interface to achieve the

  3. Performance of conical abutment (Morse Taper) connection implants: a systematic review.

    Science.gov (United States)

    Schmitt, Christian M; Nogueira-Filho, Getulio; Tenenbaum, Howard C; Lai, Jim Yuan; Brito, Carlos; Döring, Hendrik; Nonhoff, Jörg

    2014-02-01

    In this systematic review, we aimed to compare conical versus nonconical implant-abutment connection systems in terms of their in vitro and in vivo performances. An electronic search was performed using PubMed, Embase, and Medline databases with the logical operators: "dental implant" AND "dental abutment" AND ("conical" OR "taper" OR "cone"). Names of the most common conical implant-abutment connection systems were used as additional key words to detect further data. The search was limited to articles published up to November 2012. Recent publications were also searched manually in order to find any relevant studies that might have been missed using the search criteria noted above. Fifty-two studies met the inclusion criteria and were included in this systematic review. As the data and methods, as well as types of implants used was so heterogeneous, this mitigated against the performance of meta-analysis. In vitro studies indicated that conical and nonconical abutments showed sufficient resistance to maximal bending forces and fatigue loading. However, conical abutments showed superiority in terms of seal performance, microgap formation, torque maintenance, and abutment stability. In vivo studies (human and animal) indicated that conical and nonconical systems are comparable in terms of implant success and survival rates with less marginal bone loss around conical connection implants in most cases. This review indicates that implant systems using a conical implant-abutment connection, provides better results in terms of abutment fit, stability, and seal performance. These design features could lead to improvements over time versus nonconical connection systems. © 2013 Wiley Periodicals, Inc.

  4. Risks of Breast Implants

    Science.gov (United States)

    ... have a risk of developing a type of cancer called breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) in the breast tissue surrounding the implant. BIA-ALCL is not breast cancer. Women diagnosed with BIA-ALCL may need to ...

  5. Accuracy of various impression materials and methods for two implant systems: An effect size study.

    Science.gov (United States)

    Schmidt, Alexander; Häussling, Teresa; Rehmann, Peter; Schaaf, Heidrun; Wöstmann, Bernd

    2018-04-01

    An accurate impression is required for implant treatment. The aim of this in-vitro study was to determine the effect size of the impression material/method, implant system and implant angulation on impression transfer precision. An upper jaw model with three BEGO and three Straumann implants (angulations 0°, 15°, 20°) in the left and right maxilla was used as a reference model. One polyether (Impregum Penta) and two polyvinyl siloxanes (Flexitime Monophase/Aquasil Ultra Monophase) were examined with two impression techniques (open and closed tray). A total of 60 impressions were made. A coordinate measurement machine was used to measure the target variables for 3D-shift, implant axis inclination and implant axis rotation. All the data were subjected to a four-way ANOVA. The effect size (partial eta-squared [η 2 P ]) was reported. The impression material had a significant influence on the 3D shift and the implant axis inclination deviation (p-values=.000), and both factors had very large effect sizes (3D-shift [η 2 P ]=.599; implant axis inclination [η 2 P ]=.298). Impressions made with polyvinyl siloxane exhibited the highest transfer precision. When the angulation of the implants was larger, more deviations occurred for the implant axis rotational deviation. The implant systems and impression methods showed partially significant variations (p-values=.001-.639) but only very small effect sizes (η 2 P =.001-.031). The impression material had the greatest effect size on accuracy in terms of the 3D shift and the implant axis inclination. For multiunit restorations with disparallel implants, polyvinyl siloxane materials should be considered. In addition, the effect size of a multivariate investigation should be reported. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  6. Role of clinician's experience and implant design on implant stability. An ex vivo study in artificial soft bones.

    Science.gov (United States)

    Romanos, Georgios E; Basha-Hijazi, Abdulaziz; Gupta, Bhumija; Ren, Yan-Fang; Malmstrom, Hans

    2014-04-01

    Clinical experience in implant placement is important in order to prevent implant failures. However, the implant design affects the primary implant stability (PS) especially in poor quality bones. Therefore, the aim of this study was to compare the effect of clinician surgical experience on PS, when placing different type of implant designs. A total of 180 implants (90 parallel walled-P and 90 tapered-T) were placed in freshly slaughtered cow ribs. Bone quality was evaluated by two examiners during surgery and considered as 'type IV' bone. Implants (ø 5 mm, length: 15 mm, Osseotite, BIOMET 3i, Palm Beach Gardens, FL, USA) were placed by three different clinicians (master/I, good/II, non-experienced/III, under direct supervision of a manufacturer representative; 30 implants/group). An independent observer assessed the accuracy of placement by resonance frequency analysis (RFA) with implant stability quotient (ISQ) values. Two-way analysis of variance (ANOVA) and Tukey's post hoc test were used to detect the surgical experience of the clinicians and their interaction and effects of implant design on the PS. All implants were mechanically stable. The mean ISQ values were: 49.57(± 18.49) for the P-implants and 67.07(± 8.79) for the T-implants. The two-way ANOVA showed significant effects of implant design (p bone. © 2012 Wiley Periodicals, Inc.

  7. Active implantable medical device EMI assessment for wireless power transfer operating in LF and HF bands.

    Science.gov (United States)

    Hikage, Takashi; Nojima, Toshio; Fujimoto, Hiroshi

    2016-06-21

    The electromagnetic interference (EMI) imposed on active implantable medical devices by wireless power transfer systems (WPTSs) is discussed based upon results of in vitro experiments. The purpose of this study is to present comprehensive EMI test results gathered from implantable-cardiac pacemakers and implantable cardioverter defibrillators exposed to the electromagnetic field generated by several WPTSs operating in low-frequency (70 kHz-460 kHz) and high-frequency (6.78 MHz) bands. The constructed in vitro experimental test system based upon an Irnich's flat torso phantom was applied. EMI test experiments are conducted on 14 types of WPTSs including Qi-compliant system and EV-charging WPT system mounted on current production EVs. In addition, a numerical simulation model for active implantable medical device (AIMD) EMI estimation based on the experimental test system is newly proposed. The experimental results demonstrate the risk of WPTSs emitting intermittent signal to affect the correct behavior of AIMDs when operating at very short distances. The proposed numerical simulation model is applicable to obtain basically the EMI characteristics of various types of WPTSs.

  8. Ion implantation for semiconductors

    International Nuclear Information System (INIS)

    Grey-Morgan, T.

    1995-01-01

    Full text: Over the past two decades, thousands of particle accelerators have been used to implant foreign atoms like boron, phosphorus and arsenic into silicon crystal wafers to produce special embedded layers for manufacturing semiconductor devices. Depending on the device required, the atomic species, the depth of implant and doping levels are the main parameters for the implantation process; the selection and parameter control is totally automated. The depth of the implant, usually less than 1 micron, is determined by the ion energy, which can be varied between 2 and 600 keV. The ion beam is extracted from a Freeman or Bernas type ion source and accelerated to 60 keV before mass analysis. For higher beam energies postacceleration is applied up to 200 keV and even higher energies can be achieved by mass selecting multiplycharged ions, but with a corresponding reduction in beam output. Depending on the device to be manufactured, doping levels can range from 10 10 to 10 15 atoms/cm 2 and are controlled by implanter beam currents in the range up to 30mA; continuous process monitoring ensures uniformity across the wafer of better than 1 % . As semiconductor devices get smaller, additional sophistication is required in the design of the implanter. The silicon wafers charge electrically during implantation and this charge must be dissipated continuously to reduce the electrical stress in the device and avoid destructive electrical breakdown. Electron flood guns produce low energy electrons (below 10 electronvolts) to neutralize positive charge buildup and implanter design must ensure minimum contamination by other isotopic species and ensure low internal sputter rates. The pace of technology in the semiconductor industry is such that implanters are being built now for 256 Megabit circuits but which are only likely to be widely available five years from now. Several specialist companies manufacture implanter systems, each costing around US$5 million, depending on the

  9. Recent progress in the development of Terumo implantable left ventricular assist system.

    Science.gov (United States)

    Nojiri, C; Kijima, T; Maekawa, J; Horiuchi, K; Kido, T; Sugiyama, T; Mori, T; Sugiura, N; Asada, T; Shimane, H; Ozaki, T; Suzuki, M; Akamatsu, T; Akutsu, T

    1999-01-01

    The research group of the Terumo Corporation, the NTN Corporation, and Setsunan University (T. Akamatsu) has been developing an implantable left ventricular assist system (ILVAS) featuring a centrifugal blood pump with a magnetically suspended impeller (MSCP). The impeller of the MSCP is suspended by a magnetic bearing, providing contact-free rotation of the impeller inside the pump housing. Thus the MSCP is expected to provide years of long-term durability. Ex vivo chronic sheep experiments using the extracorporeal model (Model I) demonstrated long-term durability, nonthrombogenicity, and a low hemolysis rate (plasma free Hb model (Model II; 196 ml, 400 g) was evaluated ex vivo in 2 sheep and intrathoracically implanted in a small sheep (45 kg). These experiments were terminated at 70, 79, and 17 days, respectively, because of blood leakage through the connector system within the housing of Model II. There was no thrombus formation on the retrieved pump surfaces. A new connector system was introduced to the Model II pump (modified Model II), and the pump was intrathoracically implanted in a sheep. Pump flow rate was maintained at 3-7 L/min at 1700-1800 rpm. The temperature elevation on the surfaces of the motor and the electromagnet inside the pump casing was kept less than 6 degrees C. The temperature of the tissue adjacent to the pump casing became normal 10 days postoperatively. The sheep survived for more than 5 months without any sign of mechanical failure or thromboembolic complication. In vitro real-time endurance tests of motor bearings made of stainless steel and silicone nitride have been conducted for more than 1 year without any sign of bearing wear. The next prototype system (Model III), with an implantable controller and a new MSCP with reduced input power, has been developed with a view toward a totally implantable LVAS.

  10. Ultrasound guided implantation of chest port systems via the lateral subclavian vein

    International Nuclear Information System (INIS)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K.; Warm, M.; Reiser, M.; Toex, U.

    2006-01-01

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  11. Influence of controlled immediate loading and implant design on peri-implant bone formation.

    Science.gov (United States)

    Vandamme, Katleen; Naert, Ignace; Geris, Liesbet; Vander Sloten, Jozef; Puers, Robert; Duyck, Joke

    2007-02-01

    Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. A significantly higher bone area fraction was observed for SL compared with SU (pimplant contact occurred was the highest for SL and significantly different from SU (pimplant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.

  12. Modes of failure of Osteonics constrained tripolar implants: a retrospective analysis of forty-three failed implants.

    Science.gov (United States)

    Guyen, Olivier; Lewallen, David G; Cabanela, Miguel E

    2008-07-01

    The Osteonics constrained tripolar implant has been one of the most commonly used options to manage recurrent instability after total hip arthroplasty. Mechanical failures were expected and have been reported. The purpose of this retrospective review was to identify the observed modes of failure of this device. Forty-three failed Osteonics constrained tripolar implants were revised at our institution between September 1997 and April 2005. All revisions related to the constrained acetabular component only were considered as failures. All of the devices had been inserted for recurrent or intraoperative instability during revision procedures. Seven different methods of implantation were used. Operative reports and radiographs were reviewed to identify the modes of failure. The average time to failure of the forty-three implants was 28.4 months. A total of five modes of failure were observed: failure at the bone-implant interface (type I), which occurred in eleven hips; failure at the mechanisms holding the constrained liner to the metal shell (type II), in six hips; failure of the retaining mechanism of the bipolar component (type III), in ten hips; dislocation of the prosthetic head at the inner bearing of the bipolar component (type IV), in three hips; and infection (type V), in twelve hips. The mode of failure remained unknown in one hip that had been revised at another institution. The Osteonics constrained tripolar total hip arthroplasty implant is a complex device involving many parts. We showed that failure of this device can occur at most of its interfaces. It would therefore appear logical to limit its application to salvage situations.

  13. Mutual-Information-Based Incremental Relaying Communications for Wireless Biomedical Implant Systems

    Directory of Open Access Journals (Sweden)

    Yangzhe Liao

    2018-02-01

    Full Text Available Network lifetime maximization of wireless biomedical implant systems is one of the major research challenges of wireless body area networks (WBANs. In this paper, a mutual information (MI-based incremental relaying communication protocol is presented where several on-body relay nodes and one coordinator are attached to the clothes of a patient. Firstly, a comprehensive analysis of a system model is investigated in terms of channel path loss, energy consumption, and the outage probability from the network perspective. Secondly, only when the MI value becomes smaller than the predetermined threshold is data transmission allowed. The communication path selection can be either from the implanted sensor to the on-body relay then forwards to the coordinator or from the implanted sensor to the coordinator directly, depending on the communication distance. Moreover, mathematical models of quality of service (QoS metrics are derived along with the related subjective functions. The results show that the MI-based incremental relaying technique achieves better performance in comparison to our previous proposed protocol techniques regarding several selected performance metrics. The outcome of this paper can be applied to intra-body continuous physiological signal monitoring, artificial biofeedback-oriented WBANs, and telemedicine system design.

  14. Approaches and Challenges of Engineering Implantable Microelectromechanical Systems (MEMS Drug Delivery Systems for in Vitro and in Vivo Applications

    Directory of Open Access Journals (Sweden)

    Ken-Tye Yong

    2012-11-01

    Full Text Available Despite the advancements made in drug delivery systems over the years, many challenges remain in drug delivery systems for treating chronic diseases at the personalized medicine level. The current urgent need is to develop novel strategies for targeted therapy of chronic diseases. Due to their unique properties, microelectromechanical systems (MEMS technology has been recently engineered as implantable drug delivery systems for disease therapy. This review examines the challenges faced in implementing implantable MEMS drug delivery systems in vivo and the solutions available to overcome these challenges.

  15. Dynamics of bone graft healing around implants

    Directory of Open Access Journals (Sweden)

    Narayan Venkataraman

    2015-01-01

    A few questions arise pertaining to the use of bone grafts along with implants are whether these are successful in approximation with implant. Do they accelerate bone regeneration? Are all defects ultimately regenerated with new viable bone? Is the bone graft completely resorbed or integrated in new bone? Does the implant surface characteristic positively affect osseointegration when used with a bone graft? What type of graft and implant surface can be used that will have a positive effect on the healing type and time? Finally, what are the dynamics of bone graft healing around an implant? This review discusses the cellular and molecular mechanisms of bone graft healing in general and in vicinity of another foreign, avascular body, namely the implant surface, and further, the role of bone grafts in osseointegration and/or clinical success of the implants.

  16. Single-implant overdentures retained by the Novaloc attachment system: study protocol for a mixed-methods randomized cross-over trial.

    Science.gov (United States)

    de Souza, Raphael F; Bedos, Christophe; Esfandiari, Shahrokh; Makhoul, Nicholas M; Dagdeviren, Didem; Abi Nader, Samer; Jabbar, Areej A; Feine, Jocelyne S

    2018-04-23

    Overdentures retained by a single implant in the midline have arisen as a minimal implant treatment for edentulous mandibles. The success of this treatment depends on the performance of a single stud attachment that is susceptible to wear-related retention loss. Recently developed biomaterials used in attachments may result in better performance of the overdentures, offering minimal retention loss and greater patient satisfaction. These biomaterials include resistant polymeric matrixes and amorphous diamond-like carbon applied on metallic components. The objective of this explanatory mixed-methods study is to compare Novaloc, a novel attachment system with such characteristics, to a traditional alternative for single implants in the mandible of edentate elderly patients. We will carry out a randomized cross-over clinical trial comparing Novaloc attachments to Locators for single-implant mandibular overdentures in edentate elderly individuals. Participants will be followed for three months with each attachment type; patient-based, clinical, and economic outcomes will be gathered. A sample of 26 participants is estimated to be required to detect clinically relevant differences in terms of the primary outcome (patient ratings of general satisfaction). Participants will choose which attachment they wish to keep, then be interviewed about their experiences and preferences with a single implant prosthesis and with the two attachments. Data from the quantitative and qualitative assessments will be integrated through a mixed-methods explanatory strategy. A last quantitative assessment will take place after 12 months with the preferred attachment; this latter assessment will enable measurement of the attachments' long-term wear and maintenance requirements. Our results will lead to evidence-based recommendations regarding these systems, guiding providers and patients when making decisions on which attachment systems and implant numbers will be most appropriate for

  17. The Syed temporary interstitial iridium gynaecological implant: an inverse planning system

    International Nuclear Information System (INIS)

    Fung, Albert Y.C.

    2002-01-01

    Patients with advanced gynaecological cancer are often treated with a temporary interstitial implant using the Syed template and Ir-192 ribbons at the Memorial Sloan-Kettering Cancer Center. Urgency in planning is great. We created a computerized inverse planning system for the Syed temporary gynaecological implant, which optimized the ribbon strengths a few seconds after catheter digitization. Inverse planning was achieved with simulated annealing. We discovered that hand-drawn target volumes had drawbacks; hence instead of producing a grid of points based on target volume, the optimization points were generated directly from the catheter positions without requiring an explicit target volume. Since all seeds in the same ribbon had the same strength, the minimum doses were located at both ends of the implant. Optimization points generated at both ends ensured coverage of the whole implant. Inverse planning took only a few seconds, and generated plans that provide a good starting point for manual improvement. (author)

  18. A 10-year randomized clinical trial on the influence of splinted and unsplinted oral implants retaining mandibular overdentures: peri-implant outcome.

    Science.gov (United States)

    Naert, Ignace; Alsaadi, Ghada; van Steenberghe, Daniel; Quirynen, Marc

    2004-01-01

    This randomized controlled clinical trial aimed to evaluate the efficacy of splinted implants versus unsplinted implants in overdenture therapy over a 10-year period. The study sample comprised 36 completely edentulous patients, 17 men and 19 women (mean age 63.7 years). In each patient, 2 implants (Brånemark System, Nobel Biocare, Göteborg, Sweden) were placed in the interforaminal area. Three to 5 months after placement, they were connected to standard abutments. The patients were then rehabilitated with ball-retained overdentures, magnet-retained overdentures, or bar-retained overdentures (the control group). Patients were followed for 4, 12, 60, and 120 months post-abutment connection. Group means as well as linear regression models were fitted with attachment type and time as classification variables and corrected for simultaneous testing (Tukey). After 10 years, 9 patients had died and 1 was severely ill. Over 10 years, no implants failed. Mean Plaque Index, Bleeding Index, change in attachment level, Periotest values, and marginal bone level at the end of the follow-up period were not significantly different among the groups. The annual marginal bone loss, excluding the first months of remodeling, was comparable with that found around healthy natural teeth. The fact that no implants failed and that overall marginal bone loss after the first year of bone remodeling was limited suggested that implants in a 2-implant mandibular overdenture concept have an excellent prognosis in this patient population, irrespective of the attachment system used.

  19. SIMS analysis of isotopic impurities in ion implants

    International Nuclear Information System (INIS)

    Sykes, D.E.; Blunt, R.T.

    1986-01-01

    The n-type dopant species Si and Se used for ion implantation in GaAs are multi-isotopic with the most abundant isotope not chosen because of potential interferences with residual gases. SIMS analysis of a range of 29 Si implants produced by several designs of ion implanter all showed significant 28 Si impurity with a different depth distribution from that of the deliberately implanted 29 Si isotope. This effect was observed to varying degrees with all fifteen implanters examined and in every 29 Si implant analysed to date 29 Si + , 29 Si ++ and 30 Si implants all show the same effect. In the case of Se implantation, poor mass resolution results in the implantation of all isotopes with the same implant distribution (i.e. energy), whilst implants carried out with good mass resolution show the implantation of all isotopes with the characteristic lower depth distribution of the impurity isotopes as found in the Si implants. This effect has also been observed in p-type implants into GaAs (Mg) and for Ga implanted in Si. A tentative explanation of the effect is proposed. (author)

  20. A Comparison of Clinical Outcomes with Regular- and Low-Profile Totally Implanted Central Venous Port Systems

    International Nuclear Information System (INIS)

    Teichgraeber, Ulf Karl-Martin; Steitparth, Florian; Cho, Chie Hee; Benter, Thomas; Gebauer, Bernhard

    2009-01-01

    The purpose of this study was to evaluate whether low-profile totally implanted central venous port systems can reduce the late complication of skin perforation. Forty patients (age, 57 ± 13 years; 22 females, 18 males) were randomized for the implantation of a low-profile port system, and another 40 patients (age, 61 ± 14 years; 24 females, 16 males) received a regular port system as control group. Indications for port catheter implantation were malignant disease requiring chemotherapy. All port implantations were performed in the angiography suite using sonographically guided central venous puncture and fluoroscopic guidance of the catheter placement. Procedure time, number of complications (procedure-related immediate, early, and late complications), and number of explantations were assessed. Follow-up was performed for 6 months. All port implantations were successfully completed in both study groups. There were two incidents of skin perforation observed in the control group. One skin perforation occurred 13 weeks and the other 16 weeks after port implantation (incidence, 5%) in patients with regular-profile port systems. Two infections were observed, one port infection in each study group. Both infections were characterized as catheter-related infections (infection rate: 0.15 catheter-related infections per 1000 catheter days). In conclusion, low-profile port systems can be placed as safely as traditional chest ports and reduce the risk of developing skin perforations, which occurs when the port system is too tight within the port pocket.

  1. Complex regional pain syndrome type I following pacemaker implantation

    Directory of Open Access Journals (Sweden)

    Sangita Kamath

    2015-12-01

    Full Text Available A 70-year-old woman presented with burning pain and swelling over dorsum of right hand and small joints of the fingers, associated with redness, feeling of warmth, and stiffness of the fingers, with inability to bend the fingers since 2 months. The symptoms were progressively increasing in intensity for the past 1 month. There was no history of fever or trauma to the hand. Two months before her symptoms started, she had permanent pacemaker implanted for complete heart block with syncope. She was hypertensive and was on regular medication. Her X-ray of right hand showed decreased bone density (demineralisation, suggestive of osteopenia. A diagnosis of reflex sympathetic dystrophy syndrome or complex regional pain syndrome type I induced by pacemaker insertion was made. She was treated with amitriptyline and steroids, after which her symptoms improved dramatically.

  2. Bandwidth Efficient Overlapped FSK Coded Secure Command Transmission for Medical Implant Communication Systems

    Directory of Open Access Journals (Sweden)

    Selman KULAÇ

    2018-06-01

    Full Text Available Nowadays, wireless communication systems are exploited in most health care systems. Implantable Medical Systems (IMS also have wireless communication capability. However, it is very important that secure wireless communication should be provided in terms of both patient rights and patient health. Therefore, wireless transmission systems of IMS should also be robust against to eavesdroppers and adversaries. In this study, a specific overlapped and coded frequency shift keying (FSK modulation technique is developed and security containing with low complexity is provided by this proposed technique. The developed method is suitable for wireless implantable medical systems since it provides low complexity and security as well as bandwidth efficiency.

  3. Macroscopic and microscopic evaluation of a new implant design supporting immediately loaded full arch rehabilitation

    OpenAIRE

    Tetè, Stefano; Zizzari, Vincenzo; De Carlo, Alessandro; Sinjari, Bruna; Gherlone, Enrico

    2012-01-01

    The purpose of this study is to evaluate macroscopic and microscopic appearance of a new implant design, with particular emphasis given to the type of prosthesis connection. Two dental implants of the same type (Torque Type®, WinSix®, BioSAFin. S.r.l. - Ancona, Italy), with sandblasted and acid etched surfaces (Micro Rough Surface®), but differing from each other for the prosthesis connection system, were examined by scanning electron microscope (SEM) analysis at different magnifications: TTI...

  4. Clinical implementation of stereotaxic brain implant optimization

    International Nuclear Information System (INIS)

    Rosenow, U.F.; Wojcicka, J.B.

    1991-01-01

    This optimization method for stereotaxic brain implants is based on seed/strand configurations of the basic type developed for the National Cancer Institute (NCI) atlas of regular brain implants. Irregular target volume shapes are determined from delineation in a stack of contrast enhanced computed tomography scans. The neurosurgeon may then select up to ten directions, or entry points, of surgical approach of which the program finds the optimal one under the criterion of smallest target volume diameter. Target volume cross sections are then reconstructed in 5-mm-spaced planes perpendicular to the implantation direction defined by the entry point and the target volume center. This information is used to define a closed line in an implant cross section along which peripheral seed strands are positioned and which has now an irregular shape. Optimization points are defined opposite peripheral seeds on the target volume surface to which the treatment dose rate is prescribed. Three different optimization algorithms are available: linear least-squares programming, quadratic programming with constraints, and a simplex method. The optimization routine is implemented into a commercial treatment planning system. It generates coordinate and source strength information of the optimized seed configurations for further dose rate distribution calculation with the treatment planning system, and also the coordinate settings for the stereotaxic Brown-Roberts-Wells (BRW) implantation device

  5. Location of unaccessible implant surface areas during debridement in simulated peri-implantitis therapy.

    Science.gov (United States)

    Steiger-Ronay, Valerie; Merlini, Andrea; Wiedemeier, Daniel B; Schmidlin, Patrick R; Attin, Thomas; Sahrmann, Philipp

    2017-11-28

    An in vitro model for peri-implantitis treatment was used to identify areas that are clinically difficult to clean by analyzing the pattern of residual stain after debridement with commonly employed instruments. Original data from two previous publications, which simulated surgical (SA) and non-surgical (NSA) implant debridement on two different implant systems respectively, were reanalyzed regarding the localization pattern of residual stains after instrumentation. Two blinded examiners evaluated standardized photographs of 360 initially ink-stained dental implants, which were cleaned at variable defect angulations (30, 60, or 90°), using different instrument types (Gracey curette, ultrasonic scaler or air powder abrasive device) and treatment approaches (SA or NSA). Predefined implant surface areas were graded for residual stain using scores ranging from one (stain-covered) to six (clean). Score differences between respective implant areas were tested for significance by pairwise comparisons using Wilcoxon-rank-sum-tests with a significance level α = 5%. Best scores were found at the machined surface areas (SA: 5.58 ± 0.43, NSA: 4.76 ± 1.09), followed by the tips of the threads (SA: 4.29 ± 0.44, NSA: 4.43 ± 0.61), and areas between threads (SA: 3.79 ± 0.89, NSA: 2.42 ± 1.11). Apically facing threads were most difficult to clean (SA: 1.70 ± 0.92, NSA: 2.42 ± 1.11). Here, air powder abrasives provided the best results. Machined surfaces at the implant shoulder were well accessible and showed least amounts of residual stain. Apically facing thread surfaces constituted the area with most residual stain regardless of treatment approach.

  6. A study of patient satisfaction after cataract surgery with implantation of different types of intraocular lenses

    Directory of Open Access Journals (Sweden)

    Wei Ching-Kuo

    2012-10-01

    Full Text Available Abstract Background The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients’ decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. Methods This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one’s own expense, overall patient satisfaction and postoperative visual clarity. Results The results showed that the patient’s gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Conclusions Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients.

  7. A study of patient satisfaction after cataract surgery with implantation of different types of intraocular lenses.

    Science.gov (United States)

    Wei, Ching-Kuo; Wang, Shun-Mu; Lin, Jen-Chieh

    2012-10-29

    The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients' decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one's own expense, overall patient satisfaction and postoperative visual clarity. The results showed that the patient's gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients.

  8. Macroscopic and microscopic evaluation of a new implant design supporting immediately loaded full arch rehabilitation.

    Science.gov (United States)

    Tetè, Stefano; Zizzari, Vincenzo; De Carlo, Alessandro; Sinjari, Bruna; Gherlone, Enrico

    2012-04-01

    The purpose of this study is to evaluate macroscopic and microscopic appearance of a new implant design, with particular emphasis given to the type of prosthesis connection. Two dental implants of the same type (Torque Type(®), WinSix(®), BioSAFin. S.r.l. - Ancona, Italy), with sandblasted and acid etched surfaces (Micro Rough Surface(®)), but differing from each other for the prosthesis connection system, were examined by scanning electron microscope (SEM) analysis at different magnifications: TTI implant, with a hexagonal internal connection, and TTX implant, with a hexagonal external connection. SEM analysis showed that the Torque Type(®) implant is characterized by a truncated cone shape with tapered tips. The implant body showed a double loop thread and double pitch with blunt tips. For both types of connection, the implant neck was 0.7 mm in height with a 3% taper. This implant design may be able to guarantee osteotomic properties at the time of insertion in a surgical site suitably prepared, a facilitated screwing, thanks to the thread pitch and to the broad and deep draining grooves, thereby ensuring a good primary stability. The different connection design appears defined and precise, in order to ensure a good interface between the fixture and the prosthetic components. Therefore, this design appears to be particularly suitable in cases where a good primary stability is necessary and a precise coupling between endosseous and prosthetic components, as it allows an easy insertion of the fixture even in conditions of reduced bone availability, and in cases of immediately loaded full-arch rehabilitations.

  9. Radioactive implants for medical applications; Radioaktive Implantate fuer medizinische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, M.

    2008-07-01

    The long-term success of surgery is often diminished by excessive wound healing, which makes another intervention necessary. Locally applied radionuclides with short range radiation can prevent such benign hyperproliferation. As pure electron emitter with a half-life of 14.3 days and a mean energy of 694.9 keV (E{sub max}=1710.48 keV) {sup 32}P is a suitable radionuclide which can be produced from the stable {sup 31}P by the capture of thermal neutrons (1 x 10{sup 14} /s/cm{sup 2}) in a nuclear reactor. After a typical irradiation time (14 days) the ratio of {sup 32}P to {sup 31}P is 1.4 x 10{sup -5} to 1. Implants made of polymer and/or bioabsorbable material functioning as a carrier of the radioactive emitter allow - as opposed to metallic implants - for new applications for this type of radiotherapy. In this thesis a manufacturing method for previously not available organic, radioactive implants has been developed and a corresponding dosimetry system has been established. By means of ion implantation, {sup 32}P ions with up to 180 keV can be shot some 100 nm deep into organic implant materials. For a typical dose (15 Gy over 7 days, 1 mm distance from the implant) an activity of 75 kBq is needed corresponding to 1.3 x 10{sup 11} {sup 32}P ions. The sputter ion gun, which has been optimized for this application, creates an ion beam with high beam current (> 14 {mu}A P{sup -}) and low emittance (< 4 {pi} mm mrad {radical}(MeV)). Because of the good beam quality also small implants (<1 mm{sup 2}) can be manufactured with high efficiency. The unintentionally co-implanted portion of molecules and nuclides of the same mass (e.g. {sup 31}PH, {sup 16}O{sub 2} and {sup 32}S) could be reduced from approximately 500 to 50 by an improvement of the isotope selection at {sup 32}P beam creation. Hence, in comparison with the best hitherto existing implantation methods, the radiation dose of the implant could be reduced by an order of magnitude. With regard to the beta

  10. Mini-implants in the palatal slope – a retrospective analysis of implant survival and tissue reaction

    Directory of Open Access Journals (Sweden)

    Ziebura Thomas

    2012-11-01

    Full Text Available Abstract Background To identify insertion procedure and force application related complications in Jet Screw (JS type mini-implants when inserted in the palatal slope. Methods Setting and Sample Population: The Department of Orthodontics, the University Hospital Münster. Forty-one consecutively started patients treated using mini-implants in the palatal slope. In this retrospective study, 66 JS were evaluated. Patient records were used to obtain data on the mode of utilization and complications. Standardized photographs overlayed with a virtual grid served to test the hypothesis that deviations from the recommended insertion site or the type of mechanics applied might be related to complications regarding bleeding, gingival overgrowth or implant failure. Results Two implants (3% were lost, and two implants (3%, both loaded with a laterally directed force, exhibited loosening while still serving for anchorage. Complications that required treatment did not occur, the most severe problem observed being gingival proliferation which was attributable neither to patients’ age nor to applied mechanics or deviations from the ideal implant position. Conclusions The JS mini-implant is reliable for sagittal and vertical movements or anchorage purposes. Laterally directed forces might be unfavorable. The selection of implant length as well as the insertion procedure should account for the possibility of gingival overgrowth.

  11. Implantation damage in heavy gas implanted 4H-SiC

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, C. [Institut Pprime, CNRS, Université de Poitiers, ENSMA, UPR 3346, Département Physique et Mécanique des Matériaux, Bd Marie et Pierre Curie, BP 30179, 86962 Futuroscope Chasseneuil Cedex (France); Nicolaï, J., E-mail: julien.nicolai@univ-poitiers.fr [Institut Pprime, CNRS, Université de Poitiers, ENSMA, UPR 3346, Département Physique et Mécanique des Matériaux, Bd Marie et Pierre Curie, BP 30179, 86962 Futuroscope Chasseneuil Cedex (France); Declémy, A. [Institut Pprime, CNRS, Université de Poitiers, ENSMA, UPR 3346, Département Physique et Mécanique des Matériaux, Bd Marie et Pierre Curie, BP 30179, 86962 Futuroscope Chasseneuil Cedex (France); Gilabert, E. [Centre d’Etude Nucléaire de Bordeaux-Gradignan, 33175 Gradignan Cedex (France); Beaufort, M.-F.; Barbot, J.-F. [Institut Pprime, CNRS, Université de Poitiers, ENSMA, UPR 3346, Département Physique et Mécanique des Matériaux, Bd Marie et Pierre Curie, BP 30179, 86962 Futuroscope Chasseneuil Cedex (France)

    2016-05-01

    Single crystals of SiC were implanted with heavy inert gases (Xe, Ar) at elevated temperatures (300–800 °C) and for a large range of fluence (1 × 10{sup 12}–1 × 10{sup 15} ions cm{sup −2}). Thermodesorption measurements suggest that gas is trapped by implantation-induced vacancy-type defects impeding any gas diffusion. The damage accumulation versus dose was studied through the tensile elastic strain determined by using X-ray diffraction. Results show that at low dose the strain is predictable via a thermally activated direct impact model. The low thermal activation energy at saturation suggests a dynamic recovery process dominated by the migration of interstitial-type defects as its relaxation during post thermal annealing. As compared with light-gas implantation the heavy-gas to defect ratio is low enhancing the formation of strongly perturbed zones rather than the formation of bubble precursors.

  12. 3-Coil resonance-based wireless power transfer system for implantable electronic

    KAUST Repository

    Yi, Ying; Buttner, Ulrich; Fan, Yiqiang; Foulds, Ian G.

    2013-01-01

    This paper presents a 3-coil resonance-based wireless power transfer (R-WPT) system using a single layer of inductor coil windings, in a pancake configuration, in order to obtain a compact system for implantable electronic applications. A theoretical analysis and experimental measurements in terms of quality factor Q and power transfer efficiency (PTE), was done. Our proposed 3-coil scheme can achieve a high PTE with a resonance frequency of 2.46 MHz over a transfer distance of up to 30 mm, by using two 15-mm radius implant coils. The achieved experimental PTE is more than 85%at a 5 mm separation distance, and about 50% PTE at a distance of 20 mm. © 2013 IEEE.

  13. 3-Coil resonance-based wireless power transfer system for implantable electronic

    KAUST Repository

    Yi, Ying

    2013-05-01

    This paper presents a 3-coil resonance-based wireless power transfer (R-WPT) system using a single layer of inductor coil windings, in a pancake configuration, in order to obtain a compact system for implantable electronic applications. A theoretical analysis and experimental measurements in terms of quality factor Q and power transfer efficiency (PTE), was done. Our proposed 3-coil scheme can achieve a high PTE with a resonance frequency of 2.46 MHz over a transfer distance of up to 30 mm, by using two 15-mm radius implant coils. The achieved experimental PTE is more than 85%at a 5 mm separation distance, and about 50% PTE at a distance of 20 mm. © 2013 IEEE.

  14. Doping of silicon carbide by ion implantation; Dopage du carbure de silicium par implantation ionique

    Energy Technology Data Exchange (ETDEWEB)

    Gimbert, J

    1999-03-04

    It appeared that in some fields, as the hostile environments (high temperature or irradiation), the silicon compounds showed limitations resulting from the electrical and mechanical properties. Doping of 4H and 6H silicon carbide by ion implantation is studied from a physicochemical and electrical point of view. It is necessary to obtain n-type and p-type material to realize high power and/or high frequency devices, such as MESFETs and Schottky diodes. First, physical and electrical properties of silicon carbide are presented and the interest of developing a process technology on this material is emphasised. Then, physical characteristics of ion implantation and particularly classical dopant implantation, such as nitrogen, for n-type doping, and aluminium and boron, for p-type doping are described. Results with these dopants are presented and analysed. Optimal conditions are extracted from these experiences so as to obtain a good crystal quality and a surface state allowing device fabrication. Electrical conduction is then described in the 4H and 6H-SiC polytypes. Freezing of free carriers and scattering processes are described. Electrical measurements are carried out using Hall effect on Van der Panw test patterns, and 4 point probe method are used to draw the type of the material, free carrier concentrations, resistivity and mobility of the implanted doped layers. These results are commented and compared to the theoretical analysis. The influence of the technological process on electrical conduction is studied in view of fabricating implanted silicon carbide devices. (author)

  15. Rehabilitación sobre implantes oseointegrados A case with rehabilitation on boneintegrated implants

    Directory of Open Access Journals (Sweden)

    Leticia María Lemus Cruz

    2009-03-01

    Full Text Available Se presenta un caso de un paciente rehabilitado en la consulta de Implantología de la Facultad de Estomatología de Ciudad de La Habana. La historia de la implantología moderna se remonta a principios de los años 60, cuando Per-Ingvar Branemark sienta las bases de la osteointegración y describe los primeros implantes de titanio con forma de tornillo. Aunque antigua, es la prótesis más moderna. Si la meticulosidad es obligada en la elaboración de todo tipo de prótesis, en los trabajos de implantes no se admite el más mínimo fallo, desde la planificación del caso hasta la implantación de la prótesis en boca. Para obtener buenos resultados, las técnicas y los procesos han de observarse escrupulosamente. En nuestra Facultad se ha creado el Grupo de Implantología, que es el encargado de la colocación de implantes y la rehabilitación prótesica de estos. Para ello han sido utilizado diferentes tipos de implantes comercializados y patentizados al nivel mundial. Se reafirma que la rehabilitación sobre implantes mejora la calidad estética y funcional de los pacientes.A case of rehabilitation patient is presented seen in Implantation Science consulting room of Stomatology Faculty of Havana City. History of implantation science dates back to at the beginning of 60s, when Per-Ingvar Branemark creates the bases of bone-integration and to describe the firsts titanium implants in a screw form. Although ancient, it is the more modern prosthesis. If meticulousness if mandatory in elaboration of all type of prosthesis, in implants works it inadmissible the minimum of failure, from the case planning until prosthesis implantation in mouth. To achieve good results, techniques and processes has to be scrupulously observed. In our Faculty it has been created a group of Implantation Science, which is in charge of implants placement, and of the prosthetic rehabilitation of these. Thus, we used different types of marketed and showed at world level. It

  16. Comparative evaluation of the effectiveness of the implantation in the lateral part of the mandible between short tissue level (TE) and bone level (BL) implant systems.

    Science.gov (United States)

    Hadzik, Jakub; Botzenhart, Ute; Krawiec, Maciej; Gedrange, Tomasz; Heinemann, Friedhelm; Vegh, Andras; Dominiak, Marzena

    2017-09-01

    Short dental implants can be an alternative method of treatment to a vertical bone augmentation procedure at sites of reduced alveolar height. However, for successful treatment, an implant system that causes a minimal marginal bone loss (MBL) should be taken into consideration. The aim of the study has been to evaluate implantation effectiveness for bone level and tissue level short implants provided in lateral aspects of partially edentulous mandible and limited alveolar ridge height. The MBL and primary as well as secondary implant stability were determined in the study. Patients were randomly divided into two groups according to the method of treatment provided. Sixteen short Bone Level Implants (OsseoSpeed TX, Astra tech) and 16 short Tissue Level Implants (RN SLActive ® , Straumann) were successfully placed in the edentulous part of the mandible. The determination of the marginal bone level was based on radiographic evaluation after 12 and 36 weeks. Implant stability was measured immediately after insertion and after 12 weeks. The marginal bone level of Bone Level Implants was significantly lower compared to Tissue Level Implants. Furthermore, the Bone Level Implants had greater primary and secondary stability in comparison with Tissue Level Implants (Primary: 77.8 ISQ versus 66.5 ISQ; Secondary: 78.9 ISQ versus 73.9 ISQ, respectively). Since short Bone Level Implants showed a significantly decreased MBL 12 and 36 weeks after implantation as well as better results for the primary stability compared to Tissue Level Implants, they should preferentially be used for this mentioned indication. Copyright © 2017 Elsevier GmbH. All rights reserved.

  17. Intraoperative implant rod three-dimensional geometry measured by dual camera system during scoliosis surgery.

    Science.gov (United States)

    Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu

    2016-05-12

    Treatment for severe scoliosis is usually attained when the scoliotic spine is deformed and fixed by implant rods. Investigation of the intraoperative changes of implant rod shape in three-dimensions is necessary to understand the biomechanics of scoliosis correction, establish consensus of the treatment, and achieve the optimal outcome. The objective of this study was to measure the intraoperative three-dimensional geometry and deformation of implant rod during scoliosis corrective surgery.A pair of images was obtained intraoperatively by the dual camera system before rotation and after rotation of rods during scoliosis surgery. The three-dimensional implant rod geometry before implantation was measured directly by the surgeon and after surgery using a CT scanner. The images of rods were reconstructed in three-dimensions using quintic polynomial functions. The implant rod deformation was evaluated using the angle between the two three-dimensional tangent vectors measured at the ends of the implant rod.The implant rods at the concave side were significantly deformed during surgery. The highest rod deformation was found after the rotation of rods. The implant curvature regained after the surgical treatment.Careful intraoperative rod maneuver is important to achieve a safe clinical outcome because the intraoperative forces could be higher than the postoperative forces. Continuous scoliosis correction was observed as indicated by the regain of the implant rod curvature after surgery.

  18. Intraocular Implants for the Treatment of Autoimmune Uveitis

    Directory of Open Access Journals (Sweden)

    Darren J. Lee

    2015-07-01

    Full Text Available Uveitis is the third leading cause of blindness in developed countries. Currently, the most widely used treatment of non-infectious uveitis is corticosteroids. Posterior uveitis and macular edema can be treated with intraocular injection of corticosteroids, however, this is problematic in chronic cases because of the need for repeat injections. Another option is systemic immunosuppressive therapies that have their own undesirable side effects. These systemic therapies result in a widespread suppression of the entire immune system, leaving the patient susceptible to infection. Therefore, an effective localized treatment option is preferred. With the recent advances in bioengineering, biodegradable polymers that allow for a slow sustained-release of a medication. These advances have culminated in drug delivery implants that are food and drug administration (FDA approved for the treatment of non-infectious uveitis. In this review, we discuss the types of ocular implants available and some of the polymers used, implants used for the treatment of non-infectious uveitis, and bioengineered alternatives that are on the horizon.

  19. A Prospective Case-Control Clinical Study of Titanium-Zirconium Alloy Implants with a Hydrophilic Surface in Patients with Type 2 Diabetes Mellitus.

    Science.gov (United States)

    Cabrera-Domínguez, José; Castellanos-Cosano, Lizett; Torres-Lagares, Daniel; Machuca-Portillo, Guillermo

    To evaluate prospectively the behavior of narrow-diameter (3.3-mm) titanium-zirconium alloy implants with a hydrophilic surface (Straumann Roxolid SLActive) in patients with type 2 diabetes mellitus in single-unit restorations, compared with a healthy control group (assessed using the glycosylated hemoglobin HbA1c test). The patients evaluated in this study required single-unit implant treatment; 15 patients had type 2 diabetes mellitus, and 14 patients were healthy (control group [CG]). Marginal bone level (MBL) change around the implants was evaluated using conventional, sequential periapical digital radiographs. Patient HbA1c was assessed in each check-up. Normality test (Kolmogorov-Smirnov), univariate and multivariate logistic regression, analysis of variance (ANOVA), and Mann-Whitney U test were used for statistical analysis. No differences in MBL change and implant survival and success rates were found between the diabetes mellitus group (DMG) versus the control group, either during the initial recording (DMG, 0.99 ± 0.56 vs CG, 0.68 ± 0.54; P > .05) or 6 months after restoration (DMG, 1.28 ± 0.38 vs CG, 1.11 ± 0.59; P > .05). No significant correlation between HbA1c levels and MBL change was detected in these patients (P > .05). Patients with glycemic control exhibit similar outcomes to healthy individuals with regard to the investigated parameters. In light of these findings, the titanium-zirconium alloy small-diameter implants can be used in the anterior region of the mouth in type 2 diabetic patients.

  20. Ultrasound guided implantation of chest port systems via the lateral subclavian vein; Die sonographisch gezielte Implantation von Portkathetersystemen ueber die laterale Vena subclavia

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K. [Inst. fuer Radiologische Diagnostik, Univ. zu Koeln (Germany); Warm, M. [Gynaekologie, Univ. zu Koeln (Germany); Reiser, M. [Medizinische Klinik I, Univ. zu Koeln (Germany); Toex, U. [Medizinische Klinik IV, Univ. zu Koeln (Germany)

    2006-03-15

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  1. Emergency and elective implantation of covered stent systems in iatrogenic arterial injuries

    International Nuclear Information System (INIS)

    Goltz, J.P.; Kickuth, R.; Bastuerk, P.; Hoppe, H.; Triller, J.

    2011-01-01

    Purpose: To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury. Materials and Methods: Between 03/1998 and 12/2009, 31 patients underwent selective covered stent implantation after iatrogenic arterial injury. 12/31 of these patients (38.7 %) were hemodynamically unstable. Six different endovascular covered stent types were utilized. The primary endpoints of this study were technical and clinical success and rates of minor and major complications. Results: Initial angiograms demonstrated active extravasation in 19 (61.3 %) patients and pseudoaneurysms in 12 (38.7 %) patients. The following sites of bleeding origin were detected: axillary artery, subclavian artery, common iliac artery, external iliac artery, internal iliac artery, common femoral artery, superficial femoral artery, popliteal and fibular artery, femoro-popliteal and popliteo-crural bypasses, common hepatic artery, aberrant hepatic artery, cystic and gastroduodenal artery. In all patients bleeding was effectively controlled by covered stent implantation resulting in an immediate technical success of 100 %. Clinical success attributed to covered stent implantation was documented in 30 of the 31 patients (96.8 %). Major complications included death in four patients (11.1 %), acute thrombosis with arm ischemia in one patient (2.8 %) and stent fracture with associated pseudoaneurysm in another patient (2.8 %). In 2/31 patients (6.5 %) covered stent failure was detected and successfully treated by implantation of a second covered stent. Conclusion: Emergency and elective implantation of covered stents may be used for minimally invasive and effective management of iatrogenic arterial injury. (orig.)

  2. Electrically active point defects in Mg implanted n-type GaN grown by metal-organic chemical vapor deposition

    Science.gov (United States)

    Alfieri, G.; Sundaramoorthy, V. K.; Micheletto, R.

    2018-05-01

    Magnesium (Mg) is the p-type doping of choice for GaN, and selective area doping by ion implantation is a routine technique employed during device processing. While electrically active defects have been thoroughly studied in as-grown GaN, not much is known about defects generated by ion implantation. This is especially true for the case of Mg. In this study, we carried out an electrical characterization investigation of point defects generated by Mg implantation in GaN. We have found at least nine electrically active levels in the 0.2-1.2 eV energy range, below the conduction band. The isochronal annealing behavior of these levels showed that most of them are thermally stable up to 1000 °C. The nature of the detected defects is then discussed in the light of the results found in the literature.

  3. An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode.

    Science.gov (United States)

    Shon, Ahnsei; Chu, Jun-Uk; Jung, Jiuk; Kim, Hyungmin; Youn, Inchan

    2017-12-21

    Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.

  4. An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode

    Directory of Open Access Journals (Sweden)

    Ahnsei Shon

    2017-12-01

    Full Text Available Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC-compliant power transmission circuit, a medical implant communication service (MICS-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.

  5. Axial displacements in external and internal implant-abutment connection.

    Science.gov (United States)

    Lee, Ji-Hye; Kim, Dae-Gon; Park, Chan-Jin; Cho, Lee-Ra

    2014-02-01

    The purpose of this study was to evaluate the axial displacement of the abutments during clinical procedures by the tightening torque and cyclic loading. Two different implant-abutment connection systems were used (external butt joint connection [EXT]; internal tapered conical connection [INT]). The master casts with two implant replicas, angulated 10° from each other, were fabricated for each implant connection system. Four types of impression copings were assembled and tightened with the corresponding implants (hex transfer impression coping, non-hex transfer impression coping, hex pick-up impression coping, non-hex pick-up impression coping). Resin splinted abutments and final prosthesis were assembled. The axial displacement was measured from the length of each assembly, which was evaluated repeatedly, after 30 Ncm torque tightening. After 250 N cyclic loading of final prosthesis for 1,000,000 cycles, additional axial displacement was recorded. The mean axial displacement was statistically analyzed (repeated measured ANOVA). There was more axial displacement in the INT group than that of the EXT group in impression copings, resin splinted abutments, and final prosthesis. Less axial displacement was found at 1-piece non-hex transfer type impression coping than other type of impression copings in the INT group. There was more axial displacement at the final prosthesis than resin splinted abutments in the INT and the EXT groups. After 250 N cyclic loading of final prosthesis, the INT group showed more axial displacement than that of the EXT group. Internal tapered conical connection demonstrated a varying amount of axial displacement with tightening torque and cyclic loading. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  6. Ion implantation as an efficient surface treatment

    International Nuclear Information System (INIS)

    Straede, C.A.

    1992-01-01

    Ion beam processing has for several years been well established in the semiconductor industry. In recent years ion implantation of tool steels, ceramics and even plastics has gained increasing industrial awareness. The development of ion implantation to a commercially viable surface treatment of tools and spare parts working in production type environments is very dependent on technical merits, economic considerations, competing processes and highly individual barriers to acceptance for each particular application. Some examples of this will be discussed. The development of the process is very closely linked with the development of high current accelerators and their ability to efficiently manipulate the samples being treated, or to make sample manipulation superfluous by using special beam systems like the PSII. Furthermore, the ability to produce high beam currents (mA) of a wide variety of ions is crucial. Previously, it was broadly accepted that ion implantation of tools on a commercial basis generally had to be limited to nitrogen implantation. The development of implanters which can produce high beam currents of ions like B + , C + , Ti + , Cr + and others is rapidly changing this situation, and today an increasing number of commercial implantations are performed with these ions although nitrogen is still successfully used in the majority of commercial implantation. All in all, the recent development of equipment makes it possible to a higher extent than before to tailor the implantation to a specific situation. The emerging new possibilities in this direction will be discussed, and a broad selection of practical examples of ion implantation at standard low temperatures of tools and spare parts will be given. Furthermore, very interesting results have been obtained recently by implanting nitrogen at elevated temperatures, which yields a relatively deep penetration of the implanted ions. (orig./WL)

  7. The KineSpring® Knee Implant System: an implantable joint-unloading prosthesis for treatment of medial knee osteoarthritis

    Directory of Open Access Journals (Sweden)

    Clifford AG

    2013-05-01

    Full Text Available Anton G Clifford,1 Stefan M Gabriel,1 Mary O’Connell,1 David Lowe,1 Larry E Miller,2,3 Jon E Block31Moximed, Inc, Hayward, CA, USA; 2Miller Scientific Consulting, Inc, Arden, NC, USA; 3The Jon Block Group, San Francisco, CA, USAAbstract: Symptomatic medial compartment knee osteoarthritis (OA is the leading cause of musculoskeletal pain and disability in adults. Therapies intended to unload the medial knee compartment have yielded unsatisfactory results due to low patient compliance with conservative treatments and high complication rates with surgical options. There is no widely available joint-unloading treatment for medial knee OA that offers clinically important symptom alleviation, low complication risk, and high patient acceptance. The KineSpring® Knee Implant System (Moximed, Inc, Hayward, CA, USA is a first-of-its-kind, implantable, extra-articular, extra-capsular prosthesis intended to alleviate knee OA-related symptoms by reducing medial knee compartment loading while overcoming the limitations of traditional joint-unloading therapies. Preclinical and clinical studies have demonstrated excellent prosthesis durability, substantial reductions in medial compartment and total joint loads, and clinically important improvements in OA-related pain and function. The purpose of this report is to describe the KineSpring System, including implant characteristics, principles of operation, indications for use, patient selection criteria, surgical technique, postoperative care, preclinical testing, and clinical experience. The KineSpring System has potential to bridge the gap between ineffective conservative treatments and irreversible surgical interventions for medial compartment knee OA.Keywords: KineSpring, knee, medial, osteoarthritis, prosthesis

  8. A wireless power transmission system for implantable devices in freely moving rodents.

    Science.gov (United States)

    Eom, Kyungsik; Jeong, Joonsoo; Lee, Tae Hyung; Kim, Jinhyung; Kim, Junghoon; Lee, Sung Eun; Kim, Sung June

    2014-08-01

    Reliable wireless power delivery for implantable devices in animals is highly desired for safe and effective experimental use. Batteries require frequent replacement; wired connections are inconvenient and unsafe, and short-distance inductive coupling requires the attachment of an exterior transmitter to the animal's body. In this article, we propose a solution by which animals with implantable devices can move freely without attachments. Power is transmitted using coils attached to the animal's cage and is received by a receiver coil implanted in the animal. For a three-dimensionally uniform delivery of power, we designed a columnar dual-transmitter coil configuration. A resonator-based inductive link was adopted for efficient long-range power delivery, and we used a novel biocompatible liquid crystal polymer substrate as the implantable receiver device. Using this wireless power delivery system, we obtain an average power transfer efficiency of 15.2% (minimum efficiency of 10% and a standard deviation of 2.6) within a cage of 15×20×15 cm3.

  9. A Sequential Approach to Implant-Supported Overdentures.

    Science.gov (United States)

    Kosinski, Timothy

    2016-03-01

    Fabrication of implant-supported maxillary or mandibular overdentures can seem to be difficult procedures. Many things could go wrong and/or unnoticed until the fabrication has been completed. Implants must be correctly surgically placed in viable bone at the proper angulation and spacing within an arch. The type of attachment must be considered and future treatment of the appliance should be simple and efficient. The appliance must function not only initially but also for many years to come. The author has found the use of the GPS attachment to be an ideal tool to achieve the goals of retention and stability. Careful planning is the most important part of this process, and understanding the benefits and risks of creating overdentures should be well understood by the dentists. By sequentially planning and treating these types of cases, the patient is able to function reasonably during the stages of implant healing. The final prosthesis is created and remaining teeth that held the transitional appliance in place are remove on the day of final seating. This is an excellent simplified retentive system option for those patients who are anxious about losing their teeth, even those teeth that are diseased and ugly.

  10. Effect of Cyclic Loading on Micromotion at the Implant-Abutment Interface.

    Science.gov (United States)

    Karl, Matthias; Taylor, Thomas D

    2016-01-01

    Cyclic loading may cause settling of abutments mounted on dental implants, potentially affecting screw joint stability and implant-abutment micromotion. It was the goal of this in vitro study to compare micromotion of implant-abutment assemblies before and after masticatory simulation. Six groups of abutments (n = 5) for a specific tissue-level implant system with an internal octagon were subject to micromotion measurements. The implant-abutment assemblies were loaded in a universal testing machine, and an apparatus and extensometers were used to record displacement. This was done twice, in the condition in which they were received from the abutment manufacturer and after simulated loading (100,000 cycles; 100 N). Statistical analysis was based on analysis of variance, two-sample t tests (Welch tests), and Pearson product moment correlation (α = .05). The mean values for micromotion ranged from 33.15 to 63.41 μm and from 30.03 to 42.40 μm before and after load cycling. The general trend toward reduced micromotion following load cycling was statistically significant only for CAD/CAM zirconia abutments (P = .036) and for one type of clone abutment (P = .012), with no significant correlation between values measured before and after cyclic loading (Pearson product moment correlation; P = .104). While significant differences in micromotion were found prior to load cycling, no significant difference among any of the abutment types tested could be observed afterward (P > .05 in all cases). A quantifiable settling effect at the implant-abutment interface seems to result from cyclic loading, leading to a decrease in micromotion. This effect seems to be more pronounced in low-quality abutments. For the implant system tested in this study, retightening of abutment screws is recommended after an initial period of clinical use.

  11. Formation of slab waveguides in eulytine type BGO and CaF{sub 2} crystals by implantation of MeV nitrogen ions

    Energy Technology Data Exchange (ETDEWEB)

    Banyasz, I., E-mail: bakonyjako@yahoo.es [Department of Crystal Physics, Research Institute for Solid State Physics and Optics of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Berneschi, S. [Centro Studi e Ricerche ' Enrico Fermi' , Piazza del Viminale 2, 00184 Roma (Italy); MDF-Lab, ' ' Nello Carrara' ' Institute of Applied Physics, IFAC-CNR, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Khanh, N.Q.; Lohner, T. [Research Institute for Technical Physics and Materials Science of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Lengyel, K. [Department of Crystal Physics, Research Institute for Solid State Physics and Optics of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Fried, M. [Research Institute for Technical Physics and Materials Science of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Peter, A. [Department of Crystal Physics, Research Institute for Solid State Physics and Optics of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Petrik, P.; Zolnai, Z. [Research Institute for Technical Physics and Materials Science of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Watterich, A. [Department of Crystal Physics, Research Institute for Solid State Physics and Optics of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Nunzi-Conti, G.; Pelli, S.; Righini, G.C. [MDF-Lab, ' ' Nello Carrara' ' Institute of Applied Physics, IFAC-CNR, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy)

    2012-09-01

    Ion implantation, compared with other waveguide fabrication methods, has some unique advantages. It has proved to be a universal technique for producing waveguides in most optical materials. The authors of the present article reported fabrication of channel and slab waveguides in an Erbium-doped tungsten tellurite glass by implantation of MeV energy N{sup +} ions. The present article reports successful adaptation of the same technique to the fabrication of slab waveguides in eulytine type bismuth germanate (BGO) and CaF{sub 2} crystals. This is the first report on successful waveguide fabrication in these materials using 3.5 MeV N{sup +} ions at implanted fluences between 5 Multiplication-Sign 10{sup 15} and 4 Multiplication-Sign 10{sup 16} ions/cm{sup 2}. Spectroscopic ellipsometric measurements revealed the existence of guiding structures in both materials. M-line spectroscopic measurements indicated guiding effect in the as-implanted BGO up to 1550 nm and up to 980 nm in the as-implanted CaF{sub 2}. Ion implantation induced the appearance of three peaks in the UV/Vis absorption spectrum of CaF{sub 2}, that can be attributed to colour centres.

  12. Effects of pore size, implantation time and nano-surface properties on rat skin ingrowth into percutaneous porous titanium implants

    OpenAIRE

    Farrell, Brad J.; Prilutsky, Boris I.; Ritter, Jana M.; Kelley, Sean; Popat, Ketul; Pitkin, Mark

    2013-01-01

    The main problem of percutaneous osseointegrated implants is poor skin-implant integration, which may cause infection. This study investigated the effects of pore size (Small, 40–100 microns and Large, 100–160 microns), nanotubular surface treatment (Nano), and duration of implantation (3 and 6 weeks) on skin ingrowth into porous titanium. Each implant type was percutaneously inserted in the back of 35 rats randomly assigned to 7 groups. Implant extrusion rate was measured w...

  13. Effect of cyclic loading and retightening on reverse torque value in external and internal implants.

    Science.gov (United States)

    Cho, Woong-Rae; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    2015-08-01

    The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protocol. In groups with no retightening, RTV was evaluated after cyclic loading for 100,000 cycles. In groups with retightening, RTV was measured after 3, 10, 100 cycles as well as every 20,000 cycles until 100,000 cycles of loading. Every group showed decreased RTV after cyclic loading. Before and after cyclic loading, external type implants had significantly higher RTVs than internal type implants. In external type implants, retightening did not affect the decrease in RTV. In contrast, retightening 5 times and retightening after 10 cycles of dynamic loading was effective for maintaining RTV in internal type implants. Retightening of screws is more effective in internal type implants than external type implants. Retightening of screws is recommended in the early stage of functional loading.

  14. THE INFLUENCE OF SCREW TYPE, ALLOY AND CYLINDER POSITION ON THE MARGINAL FIT OF IMPLANT FRAMEWORKS BEFORE AND AFTER LASER WELDING

    OpenAIRE

    Castilio, Daniela; Pedreira, Ana Paula Ribeiro do Vale; Rossetti, Paulo Henrique Orlato; Rossetti, Leylha Maria Nunes; Bonachela, Wellington Cardoso

    2006-01-01

    Misfit at the abutment-prosthetic cylinder interface can cause loss of preload, leading to loosening or fracture of gold and titanium screws. OBJECTIVES: To evaluate the influence of screw type, alloy, and cylinder position on marginal fit of implant frameworks before and after laser welding. METHODS: After Estheticone-like abutments were screwed to the implants, thirty plastic prosthetic cylinders were mounted and waxed-up to fifteen cylindrical bars. Each specimen had three interconnected p...

  15. An image guidance system for positioning robotic cochlear implant insertion tools

    Science.gov (United States)

    Bruns, Trevor L.; Webster, Robert J.

    2017-03-01

    Cochlear implants must be inserted carefully to avoid damaging the delicate anatomical structures of the inner ear. This has motivated several approaches to improve the safety and efficacy of electrode array insertion by automating the process with specialized robotic or manual insertion tools. When such tools are used, they must be positioned at the entry point to the cochlea and aligned with the desired entry vector. This paper presents an image guidance system capable of accurately positioning a cochlear implant insertion tool. An optical tracking system localizes the insertion tool in physical space while a graphical user interface incorporates this with patient- specific anatomical data to provide error information to the surgeon in real-time. Guided by this interface, novice users successfully aligned the tool with an mean accuracy of 0.31 mm.

  16. Analysis of induced electrical currents from magnetic field coupling inside implantable neurostimulator leads

    Directory of Open Access Journals (Sweden)

    Seidman Seth J

    2011-10-01

    Full Text Available Abstract Background Over the last decade, the number of neurostimulator systems implanted in patients has been rapidly growing. Nearly 50, 000 neurostimulators are implanted worldwide annually. The most common type of implantable neurostimulators is indicated for pain relief. At the same time, commercial use of other electromagnetic technologies is expanding, making electromagnetic interference (EMI of neurostimulator function an issue of concern. Typically reported sources of neurostimulator EMI include security systems, metal detectors and wireless equipment. When near such sources, patients with implanted neurostimulators have reported adverse events such as shock, pain, and increased stimulation. In recent in vitro studies, radio frequency identification (RFID technology has been shown to inhibit the stimulation pulse of an implantable neurostimulator system during low frequency exposure at close distances. This could potentially be due to induced electrical currents inside the implantable neurostimulator leads that are caused by magnetic field coupling from the low frequency identification system. Methods To systematically address the concerns posed by EMI, we developed a test platform to assess the interference from coupled magnetic fields on implantable neurostimulator systems. To measure interference, we recorded the output of one implantable neurostimulator, programmed for best therapy threshold settings, when in close proximity to an operating low frequency RFID emitter. The output contained electrical potentials from the neurostimulator system and those induced by EMI from the RFID emitter. We also recorded the output of the same neurostimulator system programmed for best therapy threshold settings without RFID interference. Using the Spatially Extended Nonlinear Node (SENN model, we compared threshold factors of spinal cord fiber excitation for both recorded outputs. Results The electric current induced by low frequency RFID emitter

  17. In-vitro characterization of a cochlear implant system for recording of evoked compound action potentials

    Science.gov (United States)

    2012-01-01

    Background Modern cochlear implants have integrated recording systems for measuring electrically evoked compound action potentials of the auditory nerve. The characterization of such recording systems is important for establishing a reliable basis for the interpretation of signals acquired in vivo. In this study we investigated the characteristics of the recording system integrated into the MED-EL PULSARCI100 cochlear implant, especially its linearity and resolution, in order to develop a mathematical model describing the recording system. Methods In-vitro setup: The cochlear implant, including all attached electrodes, was fixed in a tank of physiologic saline solution. Sinusoidal signals of the same frequency but with different amplitudes were delivered via a signal generator for measuring and recording on a single electrode. Computer simulations: A basic mathematical model including the main elements of the recording system, i.e. amplification and digitalization stage, was developed. For this, digital output for sinusoidal input signals of different amplitudes were calculated using in-vitro recordings as reference. Results Using an averaging of 100 measurements the recording system behaved linearly down to approximately -60 dB of the input signal range. Using the same method, a system resolution of 10 μV was determined for sinusoidal signals. The simulation results were in very good agreement with the results obtained from in-vitro experiments. Conclusions The recording system implemented in the MED-EL PULSARCI100 cochlear implant for measuring the evoked compound action potential of the auditory nerve operates reliably. The developed mathematical model provides a good approximation of the recording system. PMID:22531599

  18. An Implantable Cardiovascular Pressure Monitoring System with On-Chip Antenna and RF Energy Harvesting

    Directory of Open Access Journals (Sweden)

    Yu-Chun Liu

    2015-08-01

    Full Text Available An implantable wireless system with on-chip antenna for cardiovascular pressure monitor is studied. The implantable device is operated in a batteryless manner, powered by an external radio frequency (RF power source. The received RF power level can be sensed and wirelessly transmitted along with blood pressure signal for feedback control of the external RF power. The integrated electronic system, consisting of a capacitance-to-voltage converter, an adaptive RF powering system, an RF transmitter and digital control circuitry, is simulated using a TSMC 0.18 μm CMOS technology. The implanted RF transmitter circuit is combined with a low power voltage-controlled oscillator resonating at 5.8 GHz and a power amplifier. For the design, the simulation model is setup using ADS and HFSS software. The dimension of the antenna is 1 × 0.6 × 4.8 mm3 with a 1 × 0.6 mm2 on-chip circuit which is small enough to place in human carotid artery.

  19. Evaluation of the influence of implant placement timing on the esthetic outcomes of single tooth implant treatment in the anterior maxilla: A retrospective study.

    Science.gov (United States)

    Arora, Himanshu; Ivanovski, Saso

    2018-05-15

    The purpose of this retrospective study was to investigate the influence of implant placement timing on the esthetic outcomes for single implants in the anterior maxilla. One hundred and ten patients (48 males; 62 females) who received a single-tooth implant after extraction either immediately (Type 1); after 4-8 weeks (Type 2); after 8-16 weeks (Type 3); or more than 16 weeks (Type 4) were evaluated in terms of esthetic outcomes after a mean post-placement interval of 26.3 months (range 12-116). Esthetic outcomes were measured using the Pink and White Esthetic Score (PES; WES). Stepwise regression analysis was performed to analyze the effect of timing of placement, as well as patient demographics and other clinical parameters on the esthetic outcomes. No statistically significantly differences in PES were found between the various treatment modalities with Type 1 implants (n = 33) scoring 10.58 ± 1.65 (median: 11), followed by 10.36 ± 2.09 (median: 10.5), 9.68 ± 2.43 (median: 10), and 9.63 ± 2.21 (median: 10) for Type 2 (n = 14), Type 3 (n = 19), and Type 4 (n = 44), respectively. For immediate implants, a trend towards better esthetic outcomes was observed when implant placement was done flaplessly in cases with intact buccal bone (Type 1A, median PES 11) as compared to cases with partial/complete missing buccal plates where a flap was raised (Type 1B, median PES 10). Overall, the only parameter that influenced esthetic outcomes (as measured by PES) was gender, with females having significantly superior results. The median WES was 8 and 96% of the crowns were deemed esthetically acceptable, with crowns placed by specialist prosthodontists yielding higher scores than those placed by general practitioners. Single tooth implants in the anterior maxilla showed satisfactory outcomes when measured with objective esthetic criteria. Timing of implant placement did not significantly influence the esthetic outcomes, although a trend

  20. Implantation of β-emitters on biomedical implants: 32 P isotropic ion implantation using a coaxial plasma reactor

    International Nuclear Information System (INIS)

    Fortin, M.A.; Paynter, R.W.; Sarkissian, A.; Stansfield, B.L.; Terreault, B.; Dufresne, V.

    2003-01-01

    The development of endovascular brachytherapy and the treatment of certain types of cancers (liver, lung, prostate) often require the use of beta-emitters, sometimes in the form of radioisotope-implanted devices. Among the most commonly used isotopes figures 32 P, a pure beta-emitter (maximum energy: 1.7 MeV), of which the path in biological tissues is of a few cm, restricting the impact of electron bombardment to the immediate environment of the implant. Several techniques and processes have been tried to elaborate surfaces and devices showing strongly bonded, or implanted 32 P. Anodizing, vapor phase deposition, grafting of oligonucleotides, as well as ion implantation processes have been investigated by several research groups as methods to implant beta-radioisotopes into surfaces. A coaxial plasma reactor was developed at INRS to implant radioisotopes into cylindrical metallic objects, such as coronary stents commonly used in angioplasty procedures. The dispersion of 32 P atoms on the interior surfaces of the chamber can be investigated using radiographs, contributing to image the plasma ion transport mechanisms that guide the efficiency of the implantation procedure. The amount of radioactivity on the wall liner, on the internal components, and on the biomedical implants are quantified using a surface barrier detector. A comparative study establishes a relationship between the gray scale of the radiographs, and dose measurements. A program was developed to convert the digitized images into maps showing surface dose density in mCi/cm 2 . An integration process allows the quantification of the doses on the walls and components of the reactor. Finally, the resulting integral of the 32 P dose is correlated to the initial amount of radioactivity inserted inside the implanter before the dismantling procedure. This method could be introduced as a fast and reliable way to test, qualify and assess the amount of radioactivity present on the as-produced implants

  1. In vitro deflation of prefilled saline breast implants.

    Science.gov (United States)

    Stevens, W Grant; Hirsch, Elliot M; Stoker, David A; Cohen, Robert

    2006-08-01

    The purpose of this study was to determine whether or not prefilled breast implants retain their volume in packaging. This study examined 32 Poly Implant Prosthesis prefilled textured saline breast implants. All of these implants were within the manufacturer's expiration date at the time of weighing. No holes were visible on any of the implants. All were weighed on an electronic scale. The measured weight was compared with the expected weight (based on the implant size as specified by the manufacturer) and the percentage deflation was calculated. The manufacturer declined to provide specific information about the manufacture dates of the implants; thus, relative age (rather than absolute age) was examined with respect to percentage deflation. Of the 32 implants examined, all showed some degree of deflation (range, 8.84 to 57.14 percent; 95 percent confidence interval of the mean, 22.01 +/- 4.17 percent). There was a moderate correlation (r = 0.41) between relative age of the implant and percentage deflation. From these results, it is clear that this type of prefilled saline breast implant does not maintain its volume in vitro. If these implants are used, the underfilling could contribute to a higher deflation rate and cosmetic deformity. This risk should be taken into account by plastic surgeons who use this type of implant in breast augmentation procedures.

  2. Failure of Urological Implants in Spinal Cord Injury Patients due to Infection, Malfunction, and Implants Becoming Obsolete due to Medical Progress and Age-Related Changes in Human Body Making Implant Futile: Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2013-01-01

    Full Text Available Any new clinical data, whether positive or negative, generated about a medical device should be published because health professionals should know which devices do not work, as well as those which do. We report three spinal cord injury patients in whom urological implants failed to work. In the first, paraplegic, patient, a sacral anterior root stimulator failed to produce erection, and a drug delivery system for intracavernosal administration of vasoactive drugs was therefore implanted; however, this implant never functioned (and, furthermore, such penile drug delivery systems to produce erection had effectively become obsolete following the advent of phosphodiesterase type 5 inhibitors. Subsequently, the sacral anterior root stimulator developed a malfunction and the patient therefore learned to perform self-catheterisation. In the second patient, also paraplegic, an artificial urinary sphincter was implanted but the patient developed a postoperative sacral pressure sore. Eight months later, a suprapubic cystostomy was performed as urethral catheterisation was very difficult. The pressure sore had not healed completely even after five years. In the third case, a sacral anterior root stimulator was implanted in a tetraplegic patient in whom, after five years, a penile sheath could not be fitted because of penile retraction. This patient was therefore established on urethral catheter drainage. Later, infection with Staphylococcus aureus around the receiver block necessitated its removal. In conclusion, spinal cord injury patients are at risk of developing pressure sores, wound infections, malfunction of implants, and the inability to use implants because of age-related changes, as well as running the risk of their implants becoming obsolete due to advances in medicine. Some surgical procedures such as dorsal rhizotomy are irreversible. Alternative treatments such as intermittent catheterisations may be less damaging than bladder stimulator in

  3. Tribological properties of ion-implanted steels

    International Nuclear Information System (INIS)

    Iwaki, Masaya

    1987-01-01

    The tribological properties such as surface hardness, friction and wear have been studied for low carbon steels and tool steels implanted with many types of ion including metallic elements. The hardness measured by Vickers or Knoop hardness testers as a function of normal load is dependent on the implanted species, fluence and substrate. The friction coefficients measured by Bowden-Leben type of friction tests or detected during wear tests also depend on the implantation conditions. The improvement in the wear resistance, which is most important for industrial use of implanted materials, has been investigated for AISI H13 prehardened and tool steels implanted with nitrogen and boron ions. The relationship between hardness, friction and wear is discussed in comparison with the microcharacteristics such as composition and chemical bonding states measured by means of secondary ion mass spectrometry and X-ray photoelectron spectroscopy. It is concluded that the increase in hardness and/or the decrease in friction coefficient play(s) an important role in improving the wear resistance, and the relationship between relative wear volume and relative hardness is correlated for boron and nitrogen implantation. (orig.)

  4. Influence of implant properties and local delivery systems on the outcome in operative fracture care.

    Science.gov (United States)

    Metsemakers, W-J; Moriarty, T F; Nijs, S; Pape, H C; Richards, R G

    2016-03-01

    Fracture fixation devices are implanted into a growing number of patients each year. This may be attributed to an increase in the popularity of operative fracture care and the development of ever more sophisticated implants, which may be used in even the most difficult clinical cases. Furthermore, as the general population ages, fragility fractures become more frequent. With the increase in number of surgical interventions, the absolute number of complications of these surgical treatments will inevitably rise. Implant-related infection and compromised fracture healing remain the most challenging and prevalent complications in operative fracture care. Any strategy that can help to reduce these complications will not only lead to a faster and more complete resumption of activities, but will also help to reduce the socio-economic impact. In this review we describe the influence of implant design and material choice on complication rates in trauma patients. Furthermore, we discuss the importance of local delivery systems, such as implant coatings and bone cement, and how these systems may have an impact on the prevalence, prevention and treatment outcome of these complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Weak effect of metal type and ica genes on staphylococcal infection of titanium and stainless steel implants.

    Science.gov (United States)

    Hudetz, D; Ursic Hudetz, S; Harris, L G; Luginbühl, R; Friederich, N F; Landmann, R

    2008-12-01

    Currently, ica is considered to be the major operon responsible for staphylococcal biofilm. The effect of biofilm on susceptibility to staphylococcal infection of different implant materials in vivo is unclear. The interaction of ica-positive (wild-type (WT)) and ica-negative (ica(-)) Staphylococcus aureus and Staphylococcus epidermidis strains with titanium and both smooth and rough stainless steel surfaces was studied by scanning electron microscopy in vitro and in a mouse tissue cage model during 2 weeks following perioperative or postoperative inoculation in vivo. In vitro, WT S. epidermidis adhered equally and more strongly than did WT S. aureus to all materials. Both WT strains, but not ica(-) strains, showed multilayered biofilm. In vivo, 300 CFUs of WT and ica(-)S. aureus led, in all metal cages, to an infection with a high level of planktonic CFUs and only 0.89% adherent CFUs after 8 days. In contrast, 10(6) CFUs of the WT and ica(-) strains were required for postoperative infection with S. epidermidis. In all metal types, planktonic numbers of S. epidermidis dropped to titanium cages adherent WT bacteria survived in higher numbers than ica(-) bacteria. In conclusion, the metal played a minor role in susceptibility to and persistence of staphylococcal infection; the presence of ica genes had a strong effect on biofilm in vitro and a weak effect in vivo; and S. epidermidis was more pathogenic when introduced during implantation than after implantation.

  6. Dental Implants in an Aged Population: Evaluation of Periodontal Health, Bone Loss, Implant Survival, and Quality of Life.

    Science.gov (United States)

    Becker, William; Hujoel, Philippe; Becker, Burton E; Wohrle, Peter

    2016-06-01

    To evaluate aged partially and fully edentulous patients who received dental implants and were maintained over time. Further, to determine how the partially and edentulous ageing populations (65 and above) with dental implants maintain bone levels, proper oral hygiene, and perceive benefits of dental implants. Since 1995, patients receiving dental implants have been prospectively entered into an Access-based computerized program (Triton Tacking System). Patient demographics (age, sex), bone quality, quantity, implant location, and type of surgery have been continuously entered into the database. The database was queried for patients receiving implants (first stage) between 66 and 93 years of age. Thirty-one patients were within this age group. Twenty-five patients returned to the clinic for periodontal and dental implant evaluation. The Periodontal Index was used to evaluate selected teeth in terms of probing depth, bleeding on probing, plaque accumulation, and mobility. Using NIH Image J, radiographs taken at second stage and last examination were measured for changes in interproximal bone levels. Once identified, each patient anomalously filled out an abbreviated quality of health life form. Due to small sample size, descriptive statistics were used to compare clinical findings. Fifteen males ranging from 78 to 84 (mean age 84 years) years and 16 females from 66 to 93 (mean age 83 years) (age range 66-93) were contacted by phone or mail and asked to return to our office for a re-examination. For this group, the first dental implants were placed in 1996 (n = initial two implants) and continuously recorded through 2013 (n = last seven implants). Thirty-one patients received a total of 84 implants. Two patients were edentulous, and the remaining were partially edentulous. Four implants were lost. Between implant placement and 6- to 7-year interval, 13 patients with 40 implants had a cumulative survival rate of 94.6%. Of the original group (n = 33), three

  7. Surface potential measurement of insulators in negative-ion implantation by secondary electron energy-peak shift

    International Nuclear Information System (INIS)

    Nagumo, Shoji; Toyota, Yoshitaka; Tsuji, Hiroshi; Gotoh, Yasuhito; Ishikawa, Junzo; Sakai, Shigeki; Tanjyo, Masayasu; Matsuda, Kohji.

    1993-01-01

    Negative-ion implantation is expected to realize charge-up free implantation. In this article, about a way to specify surface potential of negative-ion implanted insulator by secondary-electron-energy distribution, its principle and preliminary experimental results are described. By a measuring system with retarding field type energy analyzer, energy distribution of secondary electron from insulator of Fused Quartz in negative-carbon-ion implantation was measured. As a result the peak-shift of its energy distribution resulted according with the surface potential of insulator. It was found that surface potential of insulator is negatively charged by only several volts. Thus, negative-ion implanted insulator reduced its surface charge-up potential (without any electron supply). Therefore negative-ion implantation is considered to be much more effective method than conventional positive-ion implantation. (author)

  8. Three-dimensional accuracy of a digitally coded healing abutment implant impression system.

    Science.gov (United States)

    Ng, Simon D; Tan, Keson B; Teoh, K H; Cheng, Ansgar C; Nicholls, Jack I

    2014-01-01

    This study examined the three-dimensional (3D) accuracy of the Encode Impression System (EN) in transferring the locations of two implants from master models to test models and compared this to the direct impression (DI) technique. The effect of interimplant angulation on the 3D accuracy of both impression techniques was also evaluated. Seven sectional polymethyl methacrylate mandibular arch master models were fabricated with implants in the first premolar and first molar positions. The implants were placed parallel to each other or angulated mesiodistally or buccolingually with total divergent angles of 10, 20, or 30 degrees. Each master model was secured onto an aluminum block containing a gauge block, which defined the local coordinate references. Encode healing abutments were attached to the implants before impressions were made for the EN test models; pickup impression copings were attached for the DI test models. For the seven test groups of each impression technique, a total of 70 test models were fabricated (n = 5). The EN test models were sent to Biomet 3i for implant analog placement. The centroid of each implant or implant analog and the angular orientation of the long axis relative to the x- and y-axes were measured with a coordinate measuring machine. Statistical analyses were performed. Impression technique had a significant effect on y distortion, global linear distortion, and absolute xz and yz angular distortions. Interimplant angulation had significant effects on x and y distortions. However, neither impression technique nor interimplant angulation had a significant effect on z distortion. Distortions were observed with both impression techniques. However, the results suggest that EN was less accurate than DI.

  9. Effect of implant design and bioactive glass coating on biomechanical properties of fiber-reinforced composite implants.

    Science.gov (United States)

    Ballo, Ahmed M; Akca, Eralp; Ozen, Tuncer; Moritz, Niko; Lassila, Lippo; Vallittu, Pekka; Närhi, Timo

    2014-08-01

    This study aimed to evaluate the influence of implant design and bioactive glass (BAG) coating on the response of bone to fiber-reinforced composite (FRC) implants. Three different FRC implant types were manufactured for the study: non-threaded implants with a BAG coating; threaded implants with a BAG coating; and threaded implants with a grit-blasted surface. Thirty-six implants (six implants for each group per time point) were installed in the tibiae of six pigs. After an implantation period of 4 and 12 wk, the implants were retrieved and prepared for micro-computed tomography (micro-CT), push-out testing, and scanning electron microscopy analysis. Micro-CT demonstrated that the screw-threads and implant structure remained undamaged during the installation. The threaded FRC/BAG implants had the highest bone volume after 12 wk of implantation. The push-out strengths of the threaded FRC/BAG implants after 4 and 12 wk (463°N and 676°N, respectively) were significantly higher than those of the threaded FRC implants (416°N and 549°N, respectively) and the nonthreaded FRC/BAG implants (219°N and 430°N, respectively). Statistically significant correlation was found between bone volume and push-out strength values. This study showed that osseointegrated FRC implants can withstand the static loading up to failure without fracture, and that the addition of BAG significantly improves the push-out strength of FRC implants. © 2014 Eur J Oral Sci.

  10. Systemic Assessment of Patients Undergoing Dental Implant ...

    African Journals Online (AJOL)

    These days, dental implants are becoming routinely used as a treatment option for rehabilitation of lost teeth. Conventionally, it is only after the completion of bone healing that the dental implants are loaded into the bone. Bone healing time is approximately 3 months and. 6 months for the mandible and maxilla, respectively.

  11. Influence of implant abutment material on the color of different ceramic crown systems.

    Science.gov (United States)

    Dede, Doğu Ömür; Armağanci, Arzu; Ceylan, Gözlem; Celik, Ersan; Cankaya, Soner; Yilmaz, Burak

    2016-11-01

    Ceramics are widely used for anterior restorations; however, clinical color reproduction still constitutes a challenge particularly when the ceramic crowns are used on titanium implant abutments. The purpose of this in vitro study was to investigate the effect of implant abutment material on the color of different ceramic material systems. Forty disks (11×1.5 mm, shade A2) were fabricated from medium-opacity (mo) and high-translucency (ht) lithium disilicate (IPS e.max) blocks, an aluminous ceramic (VITA In-Ceram Alumina), and a zirconia (Zirkonzahn) ceramic system. Disks were fabricated to represent 3 different implant abutments (zirconia, gold-palladium, and titanium) and dentin (composite resin, A2 shade) as background (11×2 mm). Disk-shaped composite resin specimens in A2 shade were fabricated to represent the cement layer. The color measurements of ceramic specimens were made on composite resin abutment materials using a spectrophotometer. CIELab color coordinates were recorded, and the color coordinates measured on composite resin background served as the control group. Color differences (ΔE 00 ) between the control and test groups were calculated. The data were analyzed with 2-way analysis of variance (ANOVA) and compared with the Tukey HSD test (α=.05). The ceramics system, abutment material, and their interaction were significant for ΔE 00 values (P2.25) were observed for lithium disilicate ceramics on titanium abutments (2.46-2.50). The ΔE 00 values of lithium disilicate ceramics for gold-palladium and titanium abutments were significantly higher than for other groups (P2.25) of an implant-supported lithium disilicate ceramic restoration may be clinically unacceptable if it is fabricated over a titanium abutment. Zirconia may be a more suitable abutment material for implant-supported ceramic restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Mechanical fatigue resistance of an implantable branched lead system for a distributed set of longitudinal intrafascicular electrodes

    Science.gov (United States)

    Pena, A. E.; Kuntaegowdanahalli, S. S.; Abbas, J. J.; Patrick, J.; Horch, K. W.; Jung, R.

    2017-12-01

    Objective. A neural interface system has been developed that consists of an implantable stimulator/recorder can with a 15-electrode lead that trifurcates into three bundles of five individual wire longitudinal intrafascicular electrodes. This work evaluated the mechanical fatigue resistance of the branched lead and distributed electrode system under conditions designed to mimic anticipated strain profiles that would be observed after implantation in the human upper arm. Approach. Custom test setups and procedures were developed to apply linear or angular strain at four critical stress riser points on the lead and electrode system. Each test was performed to evaluate fatigue under a high repetition/low amplitude paradigm designed to test the effects of arm movement on the leads during activities such as walking, or under a low repetition/high amplitude paradigm designed to test the effects of more strenuous upper arm activities. The tests were performed on representative samples of the implantable lead system for human use. The specimens were fabricated using procedures equivalent to those that will be used during production of human-use implants. Electrical and visual inspections of all test specimens were performed before and after the testing procedures to assess lead integrity. Main results. Measurements obtained before and after applying repetitive strain indicated that all test specimens retained electrical continuity and that electrical impedance remained well below pre-specified thresholds for detection of breakage. Visual inspection under a microscope at 10×  magnification did not reveal any signs of damage to the wires or silicone sheathing at the stress riser points. Significance. These results demonstrate that the branched lead of this implantable neural interface system has sufficient mechanical fatigue resistance to withstand strain profiles anticipated when the system is implanted in an arm. The novel test setups and paradigms may be useful in

  13. Mechanical fatigue resistance of an implantable branched lead system for a distributed set of longitudinal intrafascicular electrodes.

    Science.gov (United States)

    Pena, A E; Kuntaegowdanahalli, S S; Abbas, J J; Patrick, J; Horch, K W; Jung, R

    2017-12-01

    A neural interface system has been developed that consists of an implantable stimulator/recorder can with a 15-electrode lead that trifurcates into three bundles of five individual wire longitudinal intrafascicular electrodes. This work evaluated the mechanical fatigue resistance of the branched lead and distributed electrode system under conditions designed to mimic anticipated strain profiles that would be observed after implantation in the human upper arm. Custom test setups and procedures were developed to apply linear or angular strain at four critical stress riser points on the lead and electrode system. Each test was performed to evaluate fatigue under a high repetition/low amplitude paradigm designed to test the effects of arm movement on the leads during activities such as walking, or under a low repetition/high amplitude paradigm designed to test the effects of more strenuous upper arm activities. The tests were performed on representative samples of the implantable lead system for human use. The specimens were fabricated using procedures equivalent to those that will be used during production of human-use implants. Electrical and visual inspections of all test specimens were performed before and after the testing procedures to assess lead integrity. Measurements obtained before and after applying repetitive strain indicated that all test specimens retained electrical continuity and that electrical impedance remained well below pre-specified thresholds for detection of breakage. Visual inspection under a microscope at 10×  magnification did not reveal any signs of damage to the wires or silicone sheathing at the stress riser points. These results demonstrate that the branched lead of this implantable neural interface system has sufficient mechanical fatigue resistance to withstand strain profiles anticipated when the system is implanted in an arm. The novel test setups and paradigms may be useful in testing other lead systems.

  14. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  15. Clinical and radiological results of patients treated with three treatment modalities for overdentures on implants of the ITI (R) Dental Implant System - A randomized controlled clinical trial

    NARCIS (Netherlands)

    Wismeijer, D; van Waas, MAJ; Mulder, J; Vermeeren, JIJF; Kalk, W

    In a randomized controlled clinical trial carried out at the Ignatius teaching hospital in Breda, The Netherlands, 110 edentulous patients with severe mandibular bone loss were treated with implants of the ITI(R) Dental Implant System using 3 different treatment strategies: a mandibular overdenture

  16. Cutaneous and systemic hypersensitivity reactions to metallic implants

    DEFF Research Database (Denmark)

    Basko-Plluska, Juliana L; Thyssen, Jacob P; Schalock, Peter C

    2011-01-01

    ) following the insertion of intravascular stents, dental implants, cardiac pacemakers, or implanted gynecologic devices. Despite repeated attempts by researchers and clinicians to further understand this difficult area of medicine, the association between metal sensitivity and cutaneous allergic reactions......Cutaneous reactions to metal implants, orthopedic or otherwise, are well documented in the literature. The first case of a dermatitis reaction over a stainless steel fracture plate was described in 1966. Most skin reactions are eczematous and allergic in nature, although urticarial, bullous......, and vasculitic eruptions may occur. Also, more complex immune reactions may develop around the implants, resulting in pain, inflammation, and loosening. Nickel, cobalt, and chromium are the three most common metals that elicit both cutaneous and extracutaneous allergic reactions from chronic internal exposure...

  17. MR images of rupture and leakage of breast implants

    International Nuclear Information System (INIS)

    Fang Ling; Liu Pengcheng; Huang Rong; Hu Huaxin; Chen Zaizhong; Du Duanming; Liu Hanqiao; Feng Fei

    2002-01-01

    Objective: To investigate the diagnostic value of magnetic resonance imaging in detecting rupture and leakage of breast implants. Methods: Seventeen cases with breast implants were imaged by MR scanner. 1 normal silicone breast implant outside the body was scanned by MR as an consultative standard. MR images of silicone implants and polypropylene acyl amine implants were classified and analyzed. Results: In 7 cases, 12 single lumen silicone implants were intact, among them 8 were silicone gel-filled implants, 4 were physiological saline-filled implants. 2 physiological saline-filled implants ruptured, among them 1 belonged to intracapsular silicone implant rupture with subsided silicone gel capsule which presented as long T 1 signal and short T 2 signal on MR images; The other belonged to extracapsular silicone implant rapture with physiological saline granule outside breast on MR images. 20 breast implants in 10 cases were injected by polypropylene acyl amine, among them 2 breast implants were intact, 16 breast implants ruptured completely with pieces and nodes of long T 1 signal and long T 2 signal on MR images, 14 of 16 also presented polypropylene acyl amine granule outside breast; 2 breast implants splited inside with linguine sign. Conclusion: The magnetic resonance imaging can make clear the type and the seat of breast implants, the type of rupture of breast implants, and the distribution of leakage material. Therefore magnetic resonance imaging can be an effective guidance for clinical operation and can be an consultative standard for follow-up

  18. Primary prevention of peri-implantitis: managing peri-implant mucositis.

    Science.gov (United States)

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; Lambert, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni E; Schwarz, Frank; Serino, Giovanni; Tomasi, Cristiano; Zitzmann, Nicola U

    2015-04-01

    comprising oral hygiene instructions and mechanical debridement revealed a reduction in clinical signs of inflammation; (vii) adjunctive measures (antiseptics, local and systemic antibiotics, air-abrasive devices) were not found to improve the efficacy of professionally administered plaque removal in reducing clinical signs of inflammation. Consensus was reached on recommendations for patients with dental implants and oral health care professionals with regard to the efficacy of measures to manage peri-implant mucositis. It was particularly emphasized that implant placement and prosthetic reconstructions need to allow proper personal cleaning, diagnosis by probing and professional plaque removal. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Impact of implant design on primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter

    2008-01-01

    Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

  20. Biomechanical evaluation of different abutment-implant connections - A nonlinear finite element analysis

    Science.gov (United States)

    Ishak, Muhammad Ikman; Shafi, Aisyah Ahmad; Rosli, M. U.; Khor, C. Y.; Zakaria, M. S.; Rahim, Wan Mohd Faizal Wan Abd; Jamalludin, Mohd Riduan

    2017-09-01

    The success of dental implant surgery is majorly dependent on the stability of prosthesis to anchor to implant body as well as the integration of implant body to bone. The attachment between dental implant body and abutment plays a vital role in attributing to the stability of dental implant system. A good connection between implant body cavity to abutment may minimize the complications of abutment loosening and implant fractures as widely reported in clinical findings. The aim of this paper is to investigate the effect of different abutment-implant connections on stress dispersion within the abutment and implant bodies as well as displacement of implant body via three-dimensional (3-D) finite element analysis (FEA). A 3-D model of mandible was reconstructed from computed tomography (CT) image datasets using an image-processing software with the selected region of interest was the left side covering the second premolar, first molar and second molar regions. The bone was modelled as compact (cortical) and porous (cancellous) structures. Besides, three implant bodies and three generic models of abutment with different types of connections - tapered interference fit (TIF), tapered integrated screwed-in (TIS) and screw retention (SR) were created using computer-aided design (CAD) software and all models were then analysed via 3D FEA software. Occlusal forces of 114.6 N, 17.2 N and 23.4 N were applied in the axial, lingual and mesio-distal directions, respectively, on the top surface of first molar crown. All planes of the mandibular bone model were rigidly fixed. The result exhibited that abutment with TIS connection produced the most favourable stress and displacement outcomes as compared to other attachment types. This is due to the existence of integrated screw at the bottom portion of tapered abutment which increases the motion resistance.

  1. The microstructure of type 304 stainless steel implanted with titanium and carbon and its relation to friction and wear tests

    International Nuclear Information System (INIS)

    Follstaedt, D.M.; Pope, L.E.; Knapp, J.A.; Picraux, S.T.; Yost, F.G.

    1983-01-01

    The authors have used transmission electron microscopy to examine the microstructure of type 304 stainless steel which was ion implanted with high doses (2 X 10 17 atoms cm -2 ) of titanium and carbon. It is found that the resulting surface alloy is an amorphous phase similar to that observed when pure iron is identically implanted. This result is important for identifying the mechanisms by which the coefficient of friction and the wear depth are reduced in unlubricated pin-on-disc tests of type 304 stainless steel implanted with titanium and carbon. The effect of temperature on the amorphous alloy during annealing in the microscope has also been examined. It is found that devitrification begins after 15 min at 500 0 C and that the alloy fully crystallizes into f.c.c., b.c.c. and TiC phases after 15 min at 650 0 C. A comparison of mechanical test results from devitrified specimens with results from amorphous specimens demonstrates that the reduction in the coefficient of friction correlates with the presence of the amorphous layer, whereas the reduction in the wear depth is obtained for both amorphous and crystalline alloys. (Auth.)

  2. Precipitation processes in implanted materials

    International Nuclear Information System (INIS)

    Borders, J.A.

    1978-01-01

    Ion implantation is a nonequilibrium process. It is possible to implant materials with impurities to concentration levels which exceed the solid solubilities. The return of the system to thermodynamic equilibrium is often accomplished by precipitation of the implanted species or a compound involving atoms of both the host and the implanted species. This may involve long time scales when taking place at room temperature or it may take place during the implantation

  3. Microbiological outcome of two screw-shaped titanium implant systems placed following a split-mouth randomised protocol, at the 12th year of follow-up after loading.

    Science.gov (United States)

    Van Assche, Nele; Pittayapat, Pisha; Jacobs, Reinhilde; Pauwels, Martine; Teughels, Wim; Quirynen, Marc

    2011-01-01

    To compare the subgingival microbiota around two differently designed implant systems that were in function for more than 12 years in a randomised split-mouth study design, and to compare the outcome with natural dentition. A total of 18 partially edentulous patients received at least two TiOblast™ (Astra Tech) and two Brånemark (Nobel Biocare) implants following a split-mouth design. At the last follow-up visit, periodontal parameters (probing depth, bleeding on probing and plaque) were recorded and intraoral radiographs were taken to calculate bone loss. Subgingival plaque samples were collected for culture, qPCR and checkerboard DNA-DNA hybridisation analysis. These data were related to implant design and bone loss. This study setup allowed a comparison of 34 Astra Tech (Impl A) with 32 Brånemark (Impl B) implants. During the 12-year follow up, five patients dropped out. One Brånemark implant was lost before abutment connection in a dropout patient. Mean bone loss between loading and year 12 was 0.7 mm (range: -0.8-5.8) (Impl A), and 0.4 mm (range: -1.1-4.1) (Impl B). No significant microbiological differences (qualitative and quantitative) could be observed between both implant types. Compared to teeth, subgingival plaque samples from implants did not reach the concentration of pathogens, even after 12 years of function. These data show that both implant systems (with differences in macro-design and surface characteristics), in patients with good oral hygiene and a stable periodontal condition, can maintain a successful treatment outcome without significant subgingival microbiological differences after 12 years of loading. The presence of periodontopathogens did not necessarily result in bone loss.

  4. Zero-fluoroscopy permanent pacemaker implantation using Ensite NavX system: Clinical viability or fanciful technique?

    Science.gov (United States)

    Guo, Ping; Qiu, Jie; Wang, Yan; Chen, Guangzhi; Proietti, Riccardo; Fadhle, Al-Selmi; Zhao, Chunxia; Wen Wang, Dao

    2018-02-01

    Fluoroscopy is the imaging modality routinely used for cardiac device implantation and electrophysiological procedures. Due to the rising concern regarding the harmful effects of radiation exposure to both the patients and operation staffs, novel 3D mapping systems have been developed and implemented in electrophysiological procedure for the navigation of catheters inside the heart chambers. Their applicability in cardiac device implantation has been rarely reported. Our aim is to evaluate the feasibility and safety of permanent pacemaker implantation without fluoroscopy. From January 2012 to June 2016, six patients (50 ± 15 years, four of six were female, one of who was at the 25th week of gestation) who underwent permanent pacemaker implantation were included (zero-fluoroscopy group). Data from 20 consecutive cases of implantation performed under fluoroscopy guidance were chosen as a control group (fluoroscopy group). Total implantation procedure time for single-chamber pacemaker was 51.3 ± 13.1 minutes in the zero-fluoroscopy group and 42.6 ± 7.4 minutes in the fluoroscopy group (P  =  0.155). The implantation procedural time for a dual-chamber pacemaker was 88.3 ± 19.6 minutes and 67.3 ± 7.6 minutes in the zero-fluoroscopy and fluoroscopy groups (P  =  0.013), respectively. No complications were observed during the procedure and the follow-up in the two groups, and all pacemakers worked with satisfactory parameters. Ensite NavX system can be used as a reliable and safe zero-fluoroscopy approach for the implantation of single- or dual-chamber permanent pacemakers in specific patients, such as pregnant women or in extreme situations when the x-ray machine is not available. © 2017 The Authors. Pacing and Clinical Electrophysiology published by Wiley Periodicals, Inc.

  5. R&D on dental implants breakage

    Science.gov (United States)

    Croitoru, Sorin Mihai; Popovici, Ion Alexandru

    2017-09-01

    Most used dental implants for human dental prostheses are of two steps type: first step means implantation and, after several months healing and osseointegration, second step is prosthesis fixture. For sure, dental implants and prostheses are meant to last for a lifetime. Still, there are unfortunate cases when dental implants break. This paper studies two steps dental implants breakage and proposes a set of instruments for replacement and restoration of the broken implant. First part of the paper sets the input data of the study: structure of the studied two steps dental implants based on two Romanian patents and values of the loading forces found in practice and specialty papers. In the second part of the paper, using DEFORM 2D™ FEM simulation software, worst case scenarios of loading dental implants are studied in order to determine which zones and components of the dental implant set are affected (broken). Last part of the paper is dedicated to design and presentation of a set for extracting and cutting tools used to restore the broken implant set.

  6. Mandibular implant-supported overdentures: Prosthetic overview

    Directory of Open Access Journals (Sweden)

    Fahad A Al-Harbi

    2018-01-01

    Full Text Available Implant-supported overdentures are becoming the treatment of choice for the completely edentulous mandible. They significantly improve the quality of life in edentulous patients. For this review article, the literature was searched to identify pertinent studies. No meta-analysis was conducted because of high heterogeneity within the literature. Accordingly, in this review article, the author provides an update on implant-supported mandible overdentures with regard to the number of implants, type of loading, stress–strain distribution, mode of implant-to-denture attachment, occlusal considerations and complications.

  7. The effects of implant-macro design on stress quantity and distribution around three types of fixtures by photo-elastic analysis

    Directory of Open Access Journals (Sweden)

    Shams Ak

    2011-04-01

    Full Text Available "nBackground and Aims: Considering the great incidence of implant failures due to high stresses around implant and at bone-implant interfaces, the aim of this study was to compare the effects of three different implant-macro designs on the quantity and distribution pattern of stresses around implants."nMaterials and Methods: In this experimental in vitro study, three types of implants including Biohorizon (4×10.5 mm, Iler (4×10 mm, and Swiss Plus (4.1×10 mm were studied by applying photo-elastic method. The implants were placed within photo-elastic models with dimensions of 50×50×10 mm. Then through open tray impressed method, crowns for each implant were constructed and cemented. Vertical and oblique loads of 100 N and 150 N were applied on the cemented crowns within polariscope machine. Then the photographs were evaluated using Isochromatic Fringe Characteristics table."nResults: Under vertical loads of 100 N and 150 N, the values for Biohorizon, Iler, Swiss Plus fixtures at the cervical region were (2.35, 3.60 N, (2.50, 3.10 N, and (1.39, 2.35 N, respectively; and in apical region the values were (1.63, 2.35 N, (1.82, 2.35 N, and (2.50, 3.10 N. Under oblique loads, the measures at the cervical region were (4.00, 5.00 N, (1.82, 5.00 N, and (5.20, 6.00 N; and in apical region were "n(1.39, 2.00 N, (4.00, 2.35 N, and (2.35, 3.00 N, respectively for mentioned implants."nConclusion: Under vertical loads, the lowest cervical stresses were observed in Swiss Plus fixture and the lowest apical stress values were recorded for Biohorizon fixture. Under oblique loads, the lowest cervical stresses were found in Iler implant and lowest apical stresses were recorded for Bohorizon.

  8. Long-term amnioinfusion through a subcutaneously implanted amniotic fluid replacement port system for treatment of PPROM in humans.

    Science.gov (United States)

    Tchirikov, Michael; Steetskamp, Joscha; Hohmann, Manfred; Koelbl, Heinz

    2010-09-01

    To introduce a novel method for the treatment of PPROM (preterm premature rupture of membranes) using continuous amnioinfusion via a subcutaneously implanted port system. After development and testing since 2001 in a fetal sheep model, the port system has been successfully implanted in two humans with PPROM. In the first case, the subcutaneous port system was implanted during the 23rd week of gestation in a 39-year-old 5th-gravida with PPROM since the 18th week of gestation; in the second case, the port system was implanted during the 24th week of gestation in a 27-year-old 3rd gravida with PPROM since the 21st week of gestation. After port implantation, 100ml/h saline solution was infused intermittently into the amniotic cavity. The whole course of treatment was supported by tocolysis. In the cases presented, gestation was terminated by cesarean section, in one case in the 29th week of gestation, and in the other case in the 30th week. The newborns showed no signs of lung hypoplasia and were successfully extubated on the 1st or 2nd day after delivery. Six months later the children did not exhibit any deviation from the normal development. Long-term amnioinfusion via a subcutaneously implanted port system could be used in humans with PPROM for prolongation of pregnancy and to avoid lung hypoplasia. Prospective randomized studies are ongoing. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  9. Load-Bearing Capacity and Retention of Newly Developed Micro-Locking Implant Prosthetic System: An In Vitro Pilot Study

    Directory of Open Access Journals (Sweden)

    Jae-Won Choi

    2018-04-01

    Full Text Available The aim of this study was to introduce the newly developed micro-locking implant prosthetic system and to evaluate the resulting its characteristics. To evaluate load-bearing capacity, 25 implants were divided into five groups: external-hexagon connection (EH, internal-octagon connection (IO, internal-hexagon connection (IH, one-body implant (OB, micro-locking implant system (ML. The maximum compressive load was measured using a universal testing machine (UTM according to the ISO 14801. Retention was evaluated in two experiments: (1 a tensile test of the structure modifications of the components (attachment and implant and (2 a tensile test after cyclic loading (total 5,000,000 cycles, 100 N, 2 Hz. The load-bearing capacity of the ML group was not significantly different from the other groups (p > 0.05. The number of balls in the attachment and the presence of a hexagonal receptacle did not show a significant correlation with retention (p > 0.05, but the shape of the retentive groove in the implant post had a statistically significant effect on retention (p < 0.05. On the other hand, the retention loss was observed during the initial 1,000,000 cycles, but an overall constant retention was maintained afterward. Various preclinical studies on this novel micro-locking implant prosthetic system should continue so that it can be applied in clinical practice.

  10. The implantation of a grid-connected PV system at CEPEL

    Energy Technology Data Exchange (ETDEWEB)

    Galdino, Marco Antonio, E-mail: marcoag@cepel.br

    2003-07-01

    This technical report presents the experience undertaken by CEPEL for implantation of a grid connected PV system at its headquarters, located in Rio de Janeiro, RJ, Brazil. This technology, although considered far from Brazilian reach, is expected to grow significantly in the near future. The paper describes briefly several aspects concerning the PV system and the DAS (data acquisition system) implemented in order to allow the continuous evaluation of its performance and operational conditions. The system was installed in December, 2002, and the data are still preliminary. (author)

  11. Modern principles of prevention of anophthalmic syndrome: formation of the locomotor stump, the types of orbital implants

    Directory of Open Access Journals (Sweden)

    I. V. Zapuskalov

    2017-01-01

    Full Text Available This article analyzes the current state of the problem of the correction of anophthalmic syndrome. Evaluated various methods of formation of the locomotor stump after removal of the eyeball, gave a detailed description of different types of materials for the fabrication of orbital implant, as well as reflect the basic principles of prevention of complications.

  12. Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature.

    Science.gov (United States)

    Klein, Doron; Hadad, Eran; Wiser, Itay; Wolf, Omer; Itzhaki Shapira, Ortal; Fucks, Shir; Heller, Lior

    2018-01-01

    Silicone breast implants from the French manufacturer Poly Implants Prosthèse (PIP) were recalled from the European market after the French regulator has revealed the implants contain non-medical-grade silicone filler. In December 2011, following a large increase in reported rupture rate and a possible cancer risk, the French Ministry of Health recommended consideration of the PIP explantation, regardless of their condition. In 2012, the Israel Ministry of Health recommended to replace the implants only upon suspected implant rupture. The aims of this study were to characterize breast-augmented Israeli patients with PIP implants, compare their outcomes with those of breast-augmented patients with different implant types, and review the current PIP literature. Breast-augmented patients who underwent an elective breast implant exchange in Israel between January 2011 and January 2017 were included in the study. Data were collected from electronic and physical medical files. There were 73 breast-augmented female patients with 146 PIP breast implants included in this study. Average implant age was 6.7 ± 2.79 years. Mean implant size was 342.8 ± 52.9 mL. Fourteen women (19 implants [16%]) had a high-grade capsular contracture (Baker grade 3-4). During exchange, 28 implants were found to be ruptured (19.2%). Less than 10 years following breast augmentation, PIP implants demonstrated higher rupture rate compared with other implants. Our data are comparable to overall available rupture rate. Among patients with definitive rupture diagnosis, an elective implant removal should be recommended. In cases of undamaged implants, plastic surgeons should also seriously consider PIP implant explantation. When the patient does not desire to remove the implant, an annual physical examination and breast ultrasound are recommended, beginning a year after augmentation.

  13. Comparison of Reconstructive Outcomes in Breast Cancer Patients With Preexisting Subpectoral Implants: Implant-Sparing Mastectomy With Delayed Implant Exchange Versus Immediate Tissue Expander Reconstruction.

    Science.gov (United States)

    Parabkaharan, Sangeetha; Melody, Megan; Trotta, Rose; Lleshi, Amina; Sun, Weihong; Smith, Paul D; Khakpour, Nazanin; Dayicioglu, Deniz

    2016-06-01

    Women who have undergone prior augmentation mammoplasty represent a unique subset of breast cancer patients with several options available for breast reconstruction. We performed a single institution review of surgical outcomes of breast reconstruction performed in patients with breast cancer with prior history of subpectoral breast augmentation. Institutional review board-approved retrospective review was conducted among patients with previously mentioned criteria treated at our institution between 2000 and 2014. Reconstructions were grouped into 2 categories as follows: (1) removal of preexisting subpectoral implant during mastectomy with immediate tissue expander placement and (2) implant-sparing mastectomy followed by delayed exchange to a larger implant. We reviewed demographics, tumor features, and reconstruction outcomes of these groups. Fifty-three patients had preexisting subpectoral implants. Of the 63 breast reconstructions performed, 18 (28.6%) had immediate tissue expander placed and 45 (71.4%) had implant-sparing mastectomy followed by delayed implant exchange. The groups were comparable based on age, body mass index, cancer type, tumor grade, TNM stage at presentation, and hormonal receptor status. No significant difference was noted between tumor margins or subsequent recurrence, mastectomy specimen weight, removed implant volume, volume of implant placed during reconstruction, or time from mastectomy to final implant placement. Rates of complications were significantly higher in the tissue expander group compared to the implant-sparing mastectomy group 7 (38.9%) versus 4 (8.9%) (P = 0.005). Implant-sparing mastectomy with delayed implant exchange in patients with preexisting subpectoral implants is safe and has fewer complications compared to tissue expander placement. There was no difference noted in the final volume of implant placed, time interval for final implant placement, or tumor margins.

  14. Fiber glass-bioactive glass composite for bone replacing and bone anchoring implants.

    Science.gov (United States)

    Vallittu, Pekka K; Närhi, Timo O; Hupa, Leena

    2015-04-01

    Although metal implants have successfully been used for decades, devices made out of metals do not meet all clinical requirements, for example, metal objects may interfere with some new medical imaging systems, while their stiffness also differs from natural bone and may cause stress-shielding and over-loading of bone. Peer-review articles and other scientific literature were reviewed for providing up-dated information how fiber-reinforced composites and bioactive glass can be utilized in implantology. There has been a lot of development in the field of composite material research, which has focused to a large extent on biodegradable composites. However, it has become evident that biostable composites may also have several clinical benefits. Fiber reinforced composites containing bioactive glasses are relatively new types of biomaterials in the field of implantology. Biostable glass fibers are responsible for the load-bearing capacity of the implant, while the dissolution of the bioactive glass particles supports bone bonding and provides antimicrobial properties for the implant. These kinds of combination materials have been used clinically in cranioplasty implants and they have been investigated also as oral and orthopedic implants. The present knowledge suggests that by combining glass fiber-reinforced composite with particles of bioactive glass can be used in cranial implants and that the combination of materials may have potential use also as other types of bone replacing and repairing implants. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  15. Influence of prosthesis design and implantation technique on implant stresses after cementless revision THR

    Directory of Open Access Journals (Sweden)

    Duda Georg N

    2011-05-01

    Full Text Available Abstract Background Femoral offset influences the forces at the hip and the implant stresses after revision THR. For extended bone defects, these forces may cause considerable bending moments within the implant, possibly leading to implant failure. This study investigates the influences of femoral anteversion and offset on stresses in the Wagner SL revision stem implant under varying extents of bone defect conditions. Methods Wagner SL revision stems with standard (34 mm and increased offset (44 mm were virtually implanted in a model femur with bone defects of variable extent (Paprosky I to IIIb. Variations in surgical technique were simulated by implanting the stems each at 4° or 14° of anteversion. Muscle and joint contact forces were applied to the reconstruction and implant stresses were determined using finite element analyses. Results Whilst increasing the implant's offset by 10 mm led to increased implant stresses (16.7% in peak tensile stresses, altering anteversion played a lesser role (5%. Generally, larger stresses were observed with reduced bone support: implant stresses increased by as much as 59% for a type IIIb defect. With increased offset, the maximum tensile stress was 225 MPa. Conclusion Although increased stresses were observed within the stem with larger offset and increased anteversion, these findings indicate that restoration of offset, key to restoring joint function, is unlikely to result in excessive implant stresses under routine activities if appropriate fixation can be achieved.

  16. New implantable therapeutic device for the control of an atrial fibrillation attack using the Peltier element.

    Science.gov (United States)

    Yambe, Tomoyuki; Sumiyoshi, Taketada; Koga, Chihiro; Shiraishi, Yasuyuki; Miura, Hidekazu; Sugita, Norihiro; Tanaka, Akira; Yoshizawa, Makoto

    2012-01-01

    For the development of the new therapeutic device for the atrial fibrillation, implantable cooling device using Peltier element was developed in this study. An implantable cooling device had been consisted from Peltier element with transcutaneous energy transmission system (TETS). 1st coil can be contacted from outside of the body, when the patients will feel palpitation. Electrical current will be induced to the implanted 2nd coil. Peltier element will able to cool the surface of the atrium. For the confirmation of the effect of the cooling device, trial manufacture model was developed. Animal experiments using six healthy adult goats after animal ethical committee allowance was carried out. Fourth intercostals space had been opened after anesthesia inhalation, and various sensors had been inserted. AF was induced by the electrical current with battery. As the results, AF had been recovered to the normal sinus rhythm after cooling in all six goats. So, this cooling system for the control of AF showed evident effect in these experiments. Smaller size cooling device has been under development aiming at totally implantable type. Catheter type cooling device for the insertion by the use of fiber-scope type is now under planning for the clinical application. This new type device may be able to become good news for the patients with uncontrollable AF.

  17. From Fertilisation to Implantation in Mammalian Pregnancy—Modulation of Early Human Reproduction by the Endocannabinoid System

    Directory of Open Access Journals (Sweden)

    Justin C. Konje

    2010-09-01

    Full Text Available There is an increasing recognition that the endocannabinoid system is the crucial cytokine-hormone system regulating early human pregnancy. The synchronous development of the fertilized embryo and the endometrium to ensure timely implantation has been shown to be one of the pivotal steps to successful implantation. This development is thought to be regulated by a finely balanced relationship between various components of the endocannabinoid system in the endometrium, the embryo and the Fallopian tube. In addition, this system has also been shown to be involved in the regulation of the development and maturation of the gametes prior to fertilization. In this review, we will examine the evidence from animal and human studies to support the role of the endocannabinoid system in gametogenesis, fertilization, implantation, early pregnancy maintenance, and in immunomodulation of pregnancy. We will discuss the role of the cannabinoid receptors and the enzymes involved in the synthesis and degradation of the key endocannabinoid ligands (e.g., anandamide and 2-arachinoylglycerol in early reproduction.

  18. Effect of higher implant density on curve correction in dystrophic thoracic scoliosis secondary to neurofibromatosis Type 1.

    Science.gov (United States)

    Li, Yang; Yuan, Xinxin; Sha, Shifu; Liu, Zhen; Zhu, Weiguo; Qiu, Yong; Wang, Bin; Yu, Yang; Zhu, Zezhang

    2017-10-01

    OBJECTIVE The aim of this study was to investigate how implant density affects radiographic results and clinical outcomes in patients with dystrophic scoliosis secondary to neurofibromatosis Type 1 (NF1). METHODS A total of 41 patients with dystrophic scoliosis secondary to NF1 who underwent 1-stage posterior correction between June 2011 and December 2013 were included. General information about patients was recorded, as were preoperative and postoperative scores from Scoliosis Research Society (SRS)-22 questionnaires. Pearson correlation analysis was used to analyze the associations among implant density, coronal Cobb angle correction rate and correction loss at last follow-up, change of sagittal curve, and apical vertebral translation. Patients were then divided into 2 groups: those with low-density and those with high-density implants. Independent-sample t-tests were used to compare demographic data, radiographic findings, and clinical outcomes before surgery and at last follow-up between the groups. RESULTS Significant correlations were found between the implant density and the coronal correction rate of the main curve (r = 0.505, p density and change of sagittal profile (p = 0.662) or apical vertebral translation (p = 0.062). The SRS-22 scores improved in the appearance, activity, and mental health domains within both groups, but there was no difference between the groups in any of the SRS-22 domains at final follow-up (p > 0.05 for all). CONCLUSIONS Although no significant differences between the high- and low-density groups were found in any of the SRS-22 domains at final follow-up, higher implant density was correlated with superior coronal correction and less postoperative correction loss in patients with dystrophic NF1-associated scoliosis.

  19. Intraoperative Cochlear Implant Device Testing Utilizing an Automated Remote System: A Prospective Pilot Study.

    Science.gov (United States)

    Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P

    2018-03-01

    Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote automated system in the apical 10 electrodes (standard 185.4 μV, SD 11.69 vs. CR

  20. Neuromuscular coordination of masticatory muscles in subjects with two types of implant-supported prostheses.

    Science.gov (United States)

    Ferrario, Virgilio F; Tartaglia, Gianluca M; Maglione, Michele; Simion, Massimo; Sforza, Chiarella

    2004-04-01

    To compare the electromyographic (EMG) characteristics of masticatory muscles in patients with fixed implant-supported prostheses and implant overdentures. Nineteen subjects aged 45-79 years were examined. Fourteen were edentulous and had been successfully rehabilitated with (a) maxillary and mandibular implant-supported fixed prostheses (seven patients); (b) mandibular implant overdentures and maxillary complete dentures (seven patients). Five control subjects had natural dentition or single/partial (no more than two teeth) tooth or implant fixed dentures. Surface EMG of the masseter and temporal muscles was performed during unilateral gum chewing and during maximum teeth clenching. To reduce biological and instrumental noise, all values were standardized as percentage of a maximum clenching on cotton rolls. During clenching, temporal muscle symmetry was larger in control subjects and fixed implant-supported prosthesis patients than in overdenture patients (analysis of variance, P=0.005). No differences were found in masseter muscle symmetry or in muscular torque. Muscle activities (integrated areas of the EMG potentials over time) were significantly larger in control subjects than in implant-supported prosthesis patients (P=0.014). In both patient groups, a poor neuromuscular coordination during chewing, with altered muscular patterns, and a smaller left-right symmetry than in control subjects were found (P=0.05). No differences in masticatory frequency were found. Surface EMG analysis of clenching and chewing showed that fixed implant-supported prostheses and implant overdentures were functionally equivalent. Neuromuscular coordination during chewing was inferior to that found in subjects with natural dentition.

  1. Surface modification of implants in long bone.

    Science.gov (United States)

    Förster, Yvonne; Rentsch, Claudia; Schneiders, Wolfgang; Bernhardt, Ricardo; Simon, Jan C; Worch, Hartmut; Rammelt, Stefan

    2012-01-01

    Coatings of orthopedic implants are investigated to improve the osteoinductive and osteoconductive properties of the implant surfaces and thus to enhance periimplant bone formation. By applying coatings that mimic the extracellular matrix a favorable environment for osteoblasts, osteoclasts and their progenitor cells is provided to promote early and strong fixation of implants. It is known that the early bone ongrowth increases primary implant fixation and reduces the risk of implant failure. This review presents an overview of coating titanium and hydroxyapatite implants with components of the extracellular matrix like collagen type I, chondroitin sulfate and RGD peptide in different small and large animal models. The influence of these components on cells, the inflammation process, new bone formation and bone/implant contact is summarized.

  2. Inductive Contactless Distance Measurement Intended for a Gastric Electrical Implant

    Directory of Open Access Journals (Sweden)

    J. Tomek

    2007-01-01

    Full Text Available For a gastric electrical stimulation project we are developing a system for on-demand switching according to the volume or elongation of the stomach wall. The system is to be implanted into the human abdomen, which limits the utilization of many possible solutions and types of sensors. Magnetic induction has been agreed as the most suitable principle, despite its direction dependency and the need of multi-axial and multiple probes for precision measurements. Possible configurations are discussed as well as the complexity of the necessary electronics and the implantation itself. For detecting food consumption, perfect precision is fortunately not necessary, but a certain compromise will still be necessary for the final system. A simple two-coil system – a transmitter and receiver and a system with a three-axial coil – have already been realized. The first system has already been successfully tested in-vivo on dogs by our US colleagues. However, if the implantation is badly performed, and the coils are completely out of axis, the system cannot sense relative changes in volume properly. The three-axial sensor presented here eliminates these problems. More complex arrangements emerging from magnetic tracking are discussed, because laboratory studies of stomach movements may require them. 

  3. Trapping of deuterium in argon-implanted nickel

    International Nuclear Information System (INIS)

    Frank, R.C.; Rehn, L.E.; Baldo, P.

    1985-01-01

    Argon ions with energy 250 keV were implanted at fluences of 2 x 10 16 cm -2 at temperatures of 500, 250, and 21 0 C, in the specimen of relatively pure polycrystalline nickel. Deuterium was introduced into the surface and implanted regions by making the specimen the negative electrode of an electrolytic cell containing 1-N pure deuterated sulfuric acid. Deuterium trapped in the vacancy complexes of the implanted regions was analyzed as a function of temperature using the vacancy complexes of the implanted regions was analyzed as a function of temperature using the 2 H( 3 He, 1 H) 4 He nuclear reaction during an isochronal annealing process. The results indicate that the types of traps and trap densities found in the regions implanted at 21 and 250 0 C were essentially identical while the trap density found in the region implanted at 500 0 C was approximately 40% of that found in the other regions. Math model comparison with the experimental results suggests the existence of at least two types of traps in each region. Trap binding enthalpies used in the math model to fit the experimental data were slightly higher for the region implanted with argon at 500 0 C than for the regions implanted at the lower temperatures. TEM studies revealed the presence of small voids in the region implanted at 500 0 as well as dislocation loops similar to those found in the regions implanted at the lower temperatures. 20 references, 2 figures

  4. Classification system on the selection of number of implants and superstructure design on the basis available vertical restorative space and interforaminal distance for implant supported mandibular overdenture

    Directory of Open Access Journals (Sweden)

    Akshay Bhargava

    2016-01-01

    Full Text Available Purpose: The rehabilitation of the edentulous mandible is a challenge due to various limiting factors, of which the available vertical restorative space (AVRS has been well understood in the literature. However, other anatomic variations such as arch form, arch size, and also the interforaminal distance (IFD (due to the presence of mandibular nerve are influential in the selection of size and position of implants, and thereby the prosthetic design. Materials and Method: In the present study, 30 edentulous patients from a group of 300 edentulous patients, representing all the three jaw relations (Class I, II, and III were evaluated for designing a classification that could help in a comprehensive treatment plan for the edentulous mandible. Dental panoramic radiographs of each individual with a trial or final prosthesis were made. The horizontal IFD and AVRS values were calculated. Results: One-way analysis of variance followed by post-hoc test (multiple comparison and Bonferroni method having P < 0.05 as significant value showed an overall mean of 38.9 mm for horizontal distance and 13.69 mm for the AVRS in 30 edentulous patients. Conclusion: The results showed that in the majority of cases (90% there is insufficient space to place a bar attachment supported by five implants for mandibular overdentures. This suggests that a universal treatment plan cannot be followed due to varying anatomic factors. Hence, it becomes imperative to have a set of clinical guidelines based on the AVRS and IFD, for the selection of implant number and type of attachment. The article proposes a simple classification system based on the AVRS and IFD for establishing guidelines in the treatment planning of the edentulous mandible, to aid in selection of implant size, number, and position along with the associated prosthetic design.

  5. Improving osseointegration of dental implants.

    Science.gov (United States)

    Elias, Carlos Nelson; Meirelles, Luiz

    2010-03-01

    In the beginning of implantology, the procedures adopted for treating patients were performed in two surgical phases with an interval of 3-6 months. Nowadays, it is possible to insert and load a dental implant in the same surgical procedure. This change is due to several factors, such as improvement of surgical technique, modifications of the implant design, increased quality of implant manufacturing, development of the surgical instruments' quality, careful patient screening and adequate treatment of the implant surface. The clinical results show that adequate treatment of surfaces is crucial for reducing healing time and treating at-risk patients. The surface properties of dental implants can be significantly improved at the manufacturing stage, affecting cells' activity during the healing phase that will ultimately determine the host tissue response, a fundamental requirement for clinical success. This review focuses on different types of dental implant surfaces and the influence of surface characteristics on osseointegration.

  6. An image-guided planning system for endosseous oral implants.

    Science.gov (United States)

    Verstreken, K; Van Cleynenbreugel, J; Martens, K; Marchal, G; van Steenberghe, D; Suetens, P

    1998-10-01

    A preoperative planning system for oral implant surgery was developed which takes as input computed tomographies (CT's) of the jaws. Two-dimensional (2-D) reslices of these axial CT slices orthogonal to a curve following the jaw arch are computed and shown together with three-dimensional (3-D) surface rendered models of the bone and computer-aided design (CAD)-like implant models. A technique is developed for scanning and visualizing an eventual existing removable prosthesis together with the bone structures. Evaluation of the planning done with the system shows a difference between 2-D and 3-D planning methods. Validation studies measure the benefits of the 3-D approach by comparing plans made in 2-D mode only with those further adjusted using the full 3-D visualization capabilities of the system. The benefits of a 3-D approach are then evident where a prosthesis is involved in the planning. For the majority of the patients, clinically important adjustments and optimizations to the 2-D plans are made once the 3-D visualization is enabled, effectively resulting in a better plan. The alterations are related to bone quality and quantity (p biomechanics (p < 0.005), and esthetics (p < 0.005), and are so obvious that the 3-D plan stands out clearly (p < 0.005). The improvements often avoid complications such as mandibular nerve damage, sinus perforations, fenestrations, or dehiscences.

  7. Magnetic resonance imaging of breast implants.

    Science.gov (United States)

    Shah, Mala; Tanna, Neil; Margolies, Laurie

    2014-12-01

    Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.

  8. Complete p-type activation in vertical-gradient freeze GaAs co-implanted with gallium and carbon

    Science.gov (United States)

    Horng, S. T.; Goorsky, M. S.

    1996-03-01

    High-resolution triple-axis x-ray diffractometry and Hall-effect measurements were used to characterize damage evolution and electrical activation in gallium arsenide co-implanted with gallium and carbon ions. Complete p-type activation of GaAs co-implanted with 5×1014 Ga cm-2 and 5×1014 C cm-2 was achieved after rapid thermal annealing at 1100 °C for 10 s. X-ray diffuse scattering was found to increase after rapid thermal annealing at 600-900 °C due to the aggregation of implantation-induced point defects. In this annealing range, there was ˜10%-72% activation. After annealing at higher annealing temperatures, the diffuse scattered intensity decreased drastically; samples that had been annealed at 1000 °C (80% activated) and 1100 °C (˜100% activated) exhibited reciprocal space maps that were indicative of high crystallinity. The hole mobility was about 60 cm2/V s for all samples annealed at 800 °C and above, indicating that the crystal perfection influences dopant activation more strongly than it influences mobility. Since the high-temperature annealing simultaneously increases dopant activation and reduces x-ray diffuse scattering, we conclude that point defect complexes which form at lower annealing temperatures are responsible for both the diffuse scatter and the reduced activation.

  9. Doping of silicon carbide by ion implantation

    International Nuclear Information System (INIS)

    Gimbert, J.

    1999-01-01

    It appeared that in some fields, as the hostile environments (high temperature or irradiation), the silicon compounds showed limitations resulting from the electrical and mechanical properties. Doping of 4H and 6H silicon carbide by ion implantation is studied from a physicochemical and electrical point of view. It is necessary to obtain n-type and p-type material to realize high power and/or high frequency devices, such as MESFETs and Schottky diodes. First, physical and electrical properties of silicon carbide are presented and the interest of developing a process technology on this material is emphasised. Then, physical characteristics of ion implantation and particularly classical dopant implantation, such as nitrogen, for n-type doping, and aluminium and boron, for p-type doping are described. Results with these dopants are presented and analysed. Optimal conditions are extracted from these experiences so as to obtain a good crystal quality and a surface state allowing device fabrication. Electrical conduction is then described in the 4H and 6H-SiC polytypes. Freezing of free carriers and scattering processes are described. Electrical measurements are carried out using Hall effect on Van der Panw test patterns, and 4 point probe method are used to draw the type of the material, free carrier concentrations, resistivity and mobility of the implanted doped layers. These results are commented and compared to the theoretical analysis. The influence of the technological process on electrical conduction is studied in view of fabricating implanted silicon carbide devices. (author)

  10. A low power flash-FPGA based brain implant micro-system of PID control.

    Science.gov (United States)

    Lijuan Xia; Fattah, Nabeel; Soltan, Ahmed; Jackson, Andrew; Chester, Graeme; Degenaar, Patrick

    2017-07-01

    In this paper, we demonstrate that a low power flash FPGA based micro-system can provide a low power programmable interface for closed-loop brain implant inter- faces. The proposed micro-system receives recording local field potential (LFP) signals from an implanted probe, performs closed-loop control using a first order control system, then converts the signal into an optogenetic control stimulus pattern. Stimulus can be implemented through optoelectronic probes. The long term target is for both fundamental neuroscience applications and for clinical use in treating epilepsy. Utilizing our device, closed-loop processing consumes only 14nJ of power per PID cycle compared to 1.52μJ per cycle for a micro-controller implementation. Compared to an application specific digital integrated circuit, flash FPGA's are inherently programmable.

  11. Polymer-based wireless implantable sensor and platform for systems biology study

    Science.gov (United States)

    Xue, Ning

    Wireless implantable MEMS (microelectromechanical systems) devices have been developed over the past decade based on the combination of bio-MEMS and Radio frequency (RF) MEMS technology. These devices require the components of wireless telemetric antenna and the corresponding circuit. In the meanwhile, biocompatible material needs to be involved in the devices design. To supply maximum power upon the implantable device at given power supply from the external coil circuit, this dissertation theoretically analyzed the mutual inductance under the positions of variety of vertical distances, lateral displacements and angular misalignments between two coils in certain surgical coils misalignment situations. A planar spiral coil has been developed as the receiver coil of the coupling system. To get maximum induced voltage over the receiver circuit, different geometries of the power coil, system operation frequencies were investigated. An intraocular pressure (IOP) sensor has been developed consisting of only biocompatible matierials-SU-8 and gold. Its size is sufficiently small to be implanted in the eye. The measurement results showed that it has relatively linear pressure response, high resolution and relatively long working stability in saline environment. Finally, a simple and low cost micro-wells bio-chip has been developed with sole polydimethylsiloxane (PDMS) to be used for single cell or small group cells isolation. By performing atomic force microscopy (AFM), contact angle and x-ray photoelectron spectroscopy (XPS) measurements on the PDMS surfaces under various surface treatment conditions, the physical and chemical surface natures were thoroughly analyzed as the basis of study of cells attachment and isolation to the surfaces.

  12. Development of microcontroller based instrumentation for low dose implantation

    International Nuclear Information System (INIS)

    Suresh, K.; Saravanan, K.; Panigrahi, B.K.; Nair, K.G.M.

    2011-01-01

    In experiments like ion implantation based ion track formations, the sample is implanted to low doses of the order of 10 10 ions/cm 2 , limiting the ion beam currents to be less than 1-5 x 10 -12 A. However the standard current integrators available are not sensitive to very low currents, causing an unacceptable high level of error in dose measurement. Hence a low dose implantation measurement system has been developed. It consists of a very sensitive low current preamplifier with full scale input 1nA/100pA, a standard current integrator, a microcontroller based interface circuit, which are connected to a personal computer(PC) through USB. Two types of the software are developed for the system: the microcontroller firmware using C and windows based virtual instrument programs using LabVIEW 7.0. Necessary precautions associated with pA level measurement like rigidly fastened good quality cables, low ripple DC power supply, shielding, close mounting of the preamplifier to the sample are adopted. After necessary calibrations with an ECIL make low current source, the system has been put into regular use. Design and development details, salient features are discussed in this paper. (author)

  13. Retention and Stability of Implant-Retained Mandibular Overdentures Using Different Types of Resilient Attachments: An In Vitro Study.

    Science.gov (United States)

    ELsyad, Moustafa Abdou; Agha, Nora Nory; Habib, Ahmed Ali

    2016-01-01

    The aim of this study was to evaluate and compare the retention and stability of mandibular implant overdentures using different types of resilient attachments. Two implant analogs were inserted in the canine areas of an acrylic edentulous mandibular model. A metal-reinforced experimental overdenture was constructed and connected to the implant analogs (on two occasions) using either resilient telescopic or Locator attachments. Locators were divided into three subgroups according to the degree of retention of the male nylon insert: Locator extra-light retention (blue insert), Locator light retention (pink insert), and Locator medium retention (transparent insert). Vertical and oblique (anterior, posterior, and lateral) dislodging forces were measured at the beginning of the study (initial retention) and after 540 cycles of denture insertion and removal (final retention). For all dislodging forces, Locator medium recorded the highest initial and final retention. Telescopic attachments recorded the lowest retention during vertical and anterior dislodging, and Locator extra-light recorded the lowest retention during lateral and posterior dislodging. For all types of Locator attachments, anterior dislodging recorded the highest initial and final retention, and lateral dislodging recorded the lowest retention. For the telescopic attachment, posterior dislodgment recorded the highest initial and final retention, and anterior dislodging recorded the lowest retention. After repeated denture insertions and removals, the highest retention and stability were recorded with Locator medium followed by Locator light. The lowest retention was recorded with resilient telescopic attachment, and the lowest stability was recorded with Locator extra-light.

  14. Macro design effects on stress distribution around implants: a photoelastic stress analysis.

    Science.gov (United States)

    Ozkir, Serhat Emre; Terzioglu, Hakan

    2012-01-01

    Biomechanics is one of the main factors for achieving long-term success of implant supported prostheses. Long-term failures mostly depend on biomechanical complications. It is important to distinguish the effects of macro design of the implants. In this study, the photoelastic response of four different types of implants that were inserted with different angulations were comparatively analyzed. The implant types investigated were screw cylinder (ITI, Straumann AG, Basel, Switzerland), stepped cylinder (Frialit2, Friadent GmbH, Manheim, Germany), root form (Camlog Rootline, Alatatec, Wilshelm, Germany), and cylindrical implant, with micro-threads on the implant neck (Astra, AstraTech, Mölndal, Sweden). In the test models, one of the implants was inserted straight, while the other one was aligned mesially with 15° angles. The superstructures were prepared as single crowns. A 150N loading was applied to the restorations throughout the test. A comparison of the implant designs showed that there were no significant differences between the straight implants; however, between the inclined implants, the most favorable stress distribution was seen with the stepped cylinder implants. The least favorable stress concentration was observed around the root formed implants. Microthreads around the implant neck appeared to be effective in a homogenous stress distribution. Observations showed that misaligned implants caused less stress than straight implants, but the stress concentrations were not homogenous. As there were observable differences between the implant types, straight placed cylindrical implants showed better stress distribution characteristics, while inclined tapering implants had better stress distribution characteristics.

  15. Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.

    Science.gov (United States)

    Depprich, Rita; Zipprich, Holger; Ommerborn, Michelle; Mahn, Eduardo; Lammers, Lydia; Handschel, Jörg; Naujoks, Christian; Wiesmann, Hans-Peter; Kübler, Norbert R; Meyer, Ulrich

    2008-11-06

    The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Göttinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.

  16. A study on the resistance at bone-implant interface during implant insertion in a cadaver goat jaw model

    Directory of Open Access Journals (Sweden)

    Goutam Das

    2016-01-01

    Full Text Available Background: The aim of the study is to determine the resistance at bone-implant interface during insertion of dental implant. Materials and Methods: Freshly procured cadaver goat mandibles were collected from slaughterhouses. Four dental implants of two different diameters were inserted into osteotomized sites of the goat mandibles. The gradual changes in resonance frequency (RF were recorded in RF analyzer for the five consecutive turns of implant insertion. Results and Observations: RF was found to be positively correlated with diameter of dental implants. Conclusion: RF analysis can be used to determine the type of resistance the implant faces during insertion and the kind of bone density through which it passes. It gives a forecast of expected initial stability.

  17. Advances in Materials for Recent Low-Profile Implantable Bioelectronics

    Directory of Open Access Journals (Sweden)

    Yanfei Chen

    2018-03-01

    Full Text Available The rapid development of micro/nanofabrication technologies to engineer a variety of materials has enabled new types of bioelectronics for health monitoring and disease diagnostics. In this review, we summarize widely used electronic materials in recent low-profile implantable systems, including traditional metals and semiconductors, soft polymers, biodegradable metals, and organic materials. Silicon-based compounds have represented the traditional materials in medical devices, due to the fully established fabrication processes. Examples include miniaturized sensors for monitoring intraocular pressure and blood pressure, which are designed in an ultra-thin diaphragm to react with the applied pressure. These sensors are integrated into rigid circuits and multiple modules; this brings challenges regarding the fundamental material’s property mismatch with the targeted human tissues, which are intrinsically soft. Therefore, many polymeric materials have been investigated for hybrid integration with well-characterized functional materials such as silicon membranes and metal interconnects, which enable soft implantable bioelectronics. The most recent trend in implantable systems uses transient materials that naturally dissolve in body fluid after a programmed lifetime. Such biodegradable metallic materials are advantageous in the design of electronics due to their proven electrical properties. Collectively, this review delivers the development history of materials in implantable devices, while introducing new bioelectronics based on bioresorbable materials with multiple functionalities.

  18. Advances in Materials for Recent Low-Profile Implantable Bioelectronics

    Science.gov (United States)

    Kim, Yun-Soung; Tillman, Bryan W.; Chun, Youngjae

    2018-01-01

    The rapid development of micro/nanofabrication technologies to engineer a variety of materials has enabled new types of bioelectronics for health monitoring and disease diagnostics. In this review, we summarize widely used electronic materials in recent low-profile implantable systems, including traditional metals and semiconductors, soft polymers, biodegradable metals, and organic materials. Silicon-based compounds have represented the traditional materials in medical devices, due to the fully established fabrication processes. Examples include miniaturized sensors for monitoring intraocular pressure and blood pressure, which are designed in an ultra-thin diaphragm to react with the applied pressure. These sensors are integrated into rigid circuits and multiple modules; this brings challenges regarding the fundamental material’s property mismatch with the targeted human tissues, which are intrinsically soft. Therefore, many polymeric materials have been investigated for hybrid integration with well-characterized functional materials such as silicon membranes and metal interconnects, which enable soft implantable bioelectronics. The most recent trend in implantable systems uses transient materials that naturally dissolve in body fluid after a programmed lifetime. Such biodegradable metallic materials are advantageous in the design of electronics due to their proven electrical properties. Collectively, this review delivers the development history of materials in implantable devices, while introducing new bioelectronics based on bioresorbable materials with multiple functionalities. PMID:29596359

  19. Implanted ZnO thin films: Microstructure, electrical and electronic properties

    International Nuclear Information System (INIS)

    Lee, J.; Metson, J.; Evans, P.J.; Kinsey, R.; Bhattacharyya, D.

    2007-01-01

    Magnetron sputtered polycrystalline ZnO thin films were implanted using Al, Ag, Sn, Sb and codoped with TiN in order to improve the conductivity and to attempt to achieve p-type behaviour. Structural and electrical properties of the implanted ZnO thin films were examined with X-ray diffractometry (XRD), scanning electron microscopy (SEM), secondary ion mass spectrometry (SIMS), atomic force microscopy (AFM) and conductivity measurements. Depth profiles of the implanted elements varied with the implant species. Implantation causes a partial amorphisation of the crystalline structure and decreases the effective grain size of the films. One of the findings is the improvement, as a consequence of implantation, in the conductivity of initially poorly conductive samples. Heavy doping may help for the conversion of conduction type of ZnO thin films. Annealing in vacuum mitigated structural damage and stress caused by implantation, and improved the conductivity of the implanted ZnO thin films

  20. Au implantation into various types of silicate glasses

    Czech Academy of Sciences Publication Activity Database

    Malinský, Petr; Macková, Anna; Bočan, Jiří; Švecová, B.; Nekvindová, P.

    2009-01-01

    Roč. 267, - (2009), s. 1575-1578 ISSN 0168-583X R&D Projects: GA MŠk(CZ) LC06041 Institutional research plan: CEZ:AV0Z10480505 Keywords : Au+ ion implantation * Glass es * RBS Depth profiling Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.156, year: 2009

  1. Spiral-Shaped Piezoelectric MEMS Cantilever Array for Fully Implantable Hearing Systems

    Directory of Open Access Journals (Sweden)

    Péter Udvardi

    2017-10-01

    Full Text Available Fully implantable, self-powered hearing aids with no external unit could significantly increase the life quality of patients suffering severe hearing loss. This highly demanding concept, however, requires a strongly miniaturized device which is fully implantable in the middle/inner ear and includes the following components: frequency selective microphone or accelerometer, energy harvesting device, speech processor, and cochlear multielectrode. Here we demonstrate a low volume, piezoelectric micro-electromechanical system (MEMS cantilever array which is sensitive, even in the lower part of the voice frequency range (300–700 Hz. The test array consisting of 16 cantilevers has been fabricated by standard bulk micromachining using a Si-on-Insulator (SOI wafer and aluminum nitride (AlN as a complementary metal-oxide-semiconductor (CMOS and biocompatible piezoelectric material. The low frequency and low device footprint are ensured by Archimedean spiral geometry and Si seismic mass. Experimentally detected resonance frequencies were validated by an analytical model. The generated open circuit voltage (3–10 mV is sufficient for the direct analog conversion of the signals for cochlear multielectrode implants.

  2. An Unusual Bone Loss Around Implants

    Directory of Open Access Journals (Sweden)

    Amirreza Rokn

    2013-01-01

    Full Text Available AbstractPre-implant disease is an inflammatory process, which can affect the surrounding tissues of a functional Osseointegrated implant that is usually as a result of a disequilibrium between the micro-flora and the body defense system.This case reports a 57 years old male with unusual bone loss around dental implants.This was an unusual case of peri-implantitis which occurred only in the implants on one side of the mouth although they all were unloaded implants.

  3. Diagnostic Imaging for Dental Implant Therapy

    Directory of Open Access Journals (Sweden)

    Aishwarya Nagarajan

    2014-01-01

    Full Text Available Dental implant is a device made of alloplastic (foreign material implanted into the jaw bone beneath the mucosal layer to support a fixed or removable dental prosthesis. Dental implants are gaining immense popularity and wide acceptance because they not only replace lost teeth but also provide permanent restorations that do not interfere with oral function or speech or compromise the self-esteem of a patient. Appropriate treatment planning for replacement of lost teeth is required and imaging plays a pivotal role to ensure a satisfactory outcome. The development of pre-surgical imaging techniques and surgical templates helps the dentist place the implants with relative ease. This article focuses on various types of imaging modalities that have a pivotal role in implant therapy.

  4. DRUGAS: implantable telemetric system for measuring the portal venous pressure: assembly aspects

    Directory of Open Access Journals (Sweden)

    Fischer Roland

    2017-09-01

    Full Text Available Developing an implantable, telemetric pressure measuring system for venous applications makes a high degree of miniaturization necessary. Thus the influence on the measurement environment is minimized and the risk of thrombosis at small flow blood velocities is decreased. But these systems are limited in terms of accuracy and resolution. The asked system requirements could only be reached by optimising the assembly and encapsulation techniques. To achieve the high degree of miniaturization numerical simulations were performed on the shape and size of the implant and led to the development of a specific metal housing consisting of two main components. A small measuring chamber will be placed into the portal vein and is rigidly fixed to a flat circular part that contains the pressure sensor chip and a transponder board and will be located outside on top of the vein. The main focus of the assembly process was based on a stress-free design and mounting of the components.

  5. Embedded System for Prosthetic Control Using Implanted Neuromuscular Interfaces Accessed Via an Osseointegrated Implant.

    Science.gov (United States)

    Mastinu, Enzo; Doguet, Pascal; Botquin, Yohan; Hakansson, Bo; Ortiz-Catalan, Max

    2017-08-01

    Despite the technological progress in robotics achieved in the last decades, prosthetic limbs still lack functionality, reliability, and comfort. Recently, an implanted neuromusculoskeletal interface built upon osseointegration was developed and tested in humans, namely the Osseointegrated Human-Machine Gateway. Here, we present an embedded system to exploit the advantages of this technology. Our artificial limb controller allows for bioelectric signals acquisition, processing, decoding of motor intent, prosthetic control, and sensory feedback. It includes a neurostimulator to provide direct neural feedback based on sensory information. The system was validated using real-time tasks characterization, power consumption evaluation, and myoelectric pattern recognition performance. Functionality was proven in a first pilot patient from whom results of daily usage were obtained. The system was designed to be reliably used in activities of daily living, as well as a research platform to monitor prosthesis usage and training, machine-learning-based control algorithms, and neural stimulation paradigms.

  6. [Fusion implants of carbon fiber reinforced plastic].

    Science.gov (United States)

    Früh, H J; Liebetrau, A; Bertagnoli, R

    2002-05-01

    Carbon fiber reinforced plastics (CFRP) are used in the medical field when high mechanical strength, innovative design, and radiolucency (see spinal fusion implants) are needed. During the manufacturing process of the material CFRP carbon fibers are embedded into a resin matrix. This resin material could be thermoset (e.g., epoxy resin EPN/DDS) or thermoplastic (e.g., PEAK). CFRP is biocompatible, radiolucent, and has higher mechanical capabilities compared to other implant materials. This publication demonstrates the manufacturing process of fusion implants made of a thermoset matrix system using a fiber winding process. The material has been used clinically since 1994 for fusion implants of the cervical and lumbar spine. The results of the fusion systems CORNERSTONE-SR C (cervical) and UNION (lumbar) showed no implant-related complications. New implant systems made of this CFRP material are under investigation and are presented.

  7. Implant Optimisation for Primary Hip Replacement in Patients over 60 Years with Osteoarthritis: A Cohort Study of Clinical Outcomes and Implant Costs Using Data from England and Wales.

    Directory of Open Access Journals (Sweden)

    Simon S Jameson

    Full Text Available Hip replacement is one of the most commonly performed surgical procedures worldwide; hundreds of implant configurations provide options for femoral head size, joint surface material and fixation method with dramatically varying costs. Robust comparative evidence to inform the choice of implant is needed. This retrospective cohort study uses linked national databases from England and Wales to determine the optimal type of replacement for patients over 60 years undergoing hip replacement for osteoarthritis.Implants included were the commonest brand from each of the four types of replacement (cemented, cementless, hybrid and resurfacing; the reference prosthesis was the cemented hip procedure. Patient reported outcome scores (PROMs, costs and risk of repeat (revision surgery were examined. Multivariable analyses included analysis of covariance to assess improvement in PROMs (Oxford hip score, OHS, and EQ5D index (9159 linked episodes and competing risks modelling of implant survival (79,775 procedures. Cost of implants and ancillary equipment were obtained from National Health Service procurement data.EQ5D score improvements (at 6 months were similar for all hip replacement types. In females, revision risk was significantly higher in cementless hip prostheses (hazard ratio, HR = 2.22, p<0.001, when compared to the reference hip. Although improvement in OHS was statistically higher (22.1 versus 20.5, p<0.001 for cementless implants, this small difference is unlikely to be clinically important. In males, revision risk was significantly higher in cementless (HR = 1.95, p = 0.003 and resurfacing implants, HR = 3.46, p<0.001, with no differences in OHS. Material costs were lowest with the reference implant (cemented, range £1103 to £1524 and highest with cementless implants (£1928 to £4285. Limitations include the design of the study, which is intrinsically vulnerable to omitted variables, a paucity of long-term implant survival data (reflecting the

  8. A study of ion implanted gallium arsenide using deep level transient spectroscopy

    International Nuclear Information System (INIS)

    Emerson, N.G.

    1981-03-01

    This thesis is concerned with the study of deep energy levels in ion implanted gallium arsenide (GaAs) using deep level transient spectroscopy (D.L.T.S.). The D.L.T.S. technique is used to characterise deep levels in terms of their activation energies and capture cross-sections and to determine their concentration profiles. The main objective is to characterise the effects on deep levels, of ion implantation and the related annealing processes. In the majority of cases assessment is carried out using Schottky barrier diodes. Low doses of selenium ions 1 to 3 x 10 12 cm -2 are implanted into vapour phase epitaxial (V.P.E.) GaAs and the effects of post-implantation thermal and pulsed laser annealing are compared. The process of oxygen implantation with doses in the range 1 x 10 12 to 5 x 10 13 cm -2 followed by thermal annealing at about 750 deg C, introduces a deep level at 0.79 eV from the conduction band. Oxygen implantation, at doses of 5 x 10 13 cm -2 , into V.P.E. GaAs produces a significant increase in the concentration of the A-centre (0.83 eV). High doses of zinc (10 15 cm -2 ) are implanted into n-type V.P.E. GaAs to form shallow p-type layers. The D.L.T.S. system described in the text is used to measure levels in the range 0.16 to 1.1 eV (for GaAs) with a sensitivity of the order 1:10 3 . (U.K.)

  9. Rehabilitation with ear prosthesis linked to osseointegrated implants.

    Science.gov (United States)

    Goiato, Marcelo C; dos Santos, Daniela M; Haddad, Marcela F; Moreno, Amália

    2012-06-01

    The absence of an ear, which can be the result of a congenital malformation, surgical tumour resection or traumatic injury, is a significant aesthetic problem. Attachment of ear prostheses with adhesives can cause local irritation for the wearer and affect the colour of the prostheses. Use of implants in craniofacial reconstruction can improve the retention and stability of prostheses giving to patient greater comfort and security relative to adhesive attachment. The aim of this report was to present a clinical case of a mutilated patient who was rehabilitated by means of installing an ear prosthesis fixed through osseointegrated implants. The patient had two implants installed in the mastoid region that were linked by a bar, and a clip-type system was used. The ear prosthesis was constructed from medical-use silicone, pigmented to match the patient's skin colour and linked to the retention system. The patient's rehabilitation was satisfactory from both a functional and an aesthetic point of view, making it possible for the patient to return to a normal social life and regain lost self-esteem. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  10. Effects of Reinforcement on Denture Strain in Maxillary Implant Overdentures: An In Vitro Study Under Various Implant Configurations.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    Maxillary implant overdentures are often designed without palatal coverage to maximize wearer comfort. Although palateless dentures have been reported to be less rigid than conventional dentures, and require reinforcement to prevent complications, there is little documentation about the effects of such reinforcement. The purpose of this study was to examine the effects of reinforcement on the strain on maxillary implant overdentures supported by implants in a variety of configurations. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar area was fabricated. Five types of experimental overdentures, with and without reinforcement, were fabricated, and two strain gauges were attached at the anterior midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain on the denture was measured. The measurements were compared using the Kruskal-Wallis test (P = .05). On both the labial and palatal sides, the strain on the palateless dentures with reinforcement was significantly lower than the strain on palateless dentures without reinforcement in all implant configurations (P overdenture with residual ridge reinforcement and a palatal bar could reduce the strain in the anterior midline to almost the same level as a denture with palatal coverage. This type of reinforcement may prevent prosthetic and implant complications.

  11. Electromagnetic interference of mobile phones with electronic implants

    International Nuclear Information System (INIS)

    Kainz, W.

    2000-03-01

    Chapter 1:Interference matrix: The objective of Chapter 1 was to give an overview of the implants used at present and their electromagnetic compatibility (EMC). The evaluation of the available literature provides an estimate of the probability of electronic implants being influenced by various interference sources. A literature search at the AKH (Allgemeines Krankenhaus) in Vienna and at the Technical University of Vienna in the FIZ (Fach-Informations-Zentrum) -Biomedizinische Technik, Medline, Pascal Biomed, CC Search und Embase databases yielded 236 relevant publications. At present 12 different implants are used: pacemaker, defibrillator, cochlear and brain-stem implants, neurostimulators, spinal-cord stimulators, spinal-fusion stimulators, telemetry systems, artificial hearts, drug-delivery systems, neurological pulse generators, visual prosthetics and implantable patient chips. The frequency with which they are used and the EMC on exposure to the various interference sources was summarized. Publications on EMC were found only for the first six implant types and only for 30% of the possible combinations of implant type and interference source. Based on the number of the implants examined, the probability of interference was calculated and summarized in the interference matrix. Chapter 2:Measurements on the phantom: No publication on the electromagnetic compatibility of neurological pulse generators (NPG) could be found. This implant has been used increasingly in the last few years to treat Parkinson's disease. A phantom was built to examine this implant at 900 MHz. The electromagnetic compatibility was measured by exposing the NPG to the fields of ten different 900 MHz GSM mobile phones. Every mobile phone was tested in three different positions relative to the phantom, with four electrode configurations and four stimulation parameters. No interference was found even at a maximum transmit power of 2 watts. Further tests with half-wave dipoles and increased

  12. Implanting inequality: empirical evidence of social and ethical risks of implantable radio-frequency identification (RFID) devices.

    Science.gov (United States)

    Monahan, Torin; Fisher, Jill A

    2010-10-01

    The aim of this study was to assess empirically the social and ethical risks associated with implantable radio-frequency identification (RFID) devices. Qualitative research included observational studies in twenty-three U.S. hospitals that have implemented new patient identification systems and eighty semi-structured interviews about the social and ethical implications of new patient identification systems, including RFID implants. The study identified three primary social and ethical risks associated with RFID implants: (i) unfair prioritization of patients based on their participation in the system, (ii) diminished trust of patients by care providers, and (iii) endangerment of patients who misunderstand the capabilities of the systems. RFID implants may aggravate inequalities in access to care without any clear health benefits. This research underscores the importance of critically evaluating new healthcare technologies from the perspective of both normative ethics and empirical ethics.

  13. Macro design effects on stress distribution around implants: A photoelastic stress analysis

    OpenAIRE

    Serhat Emre Ozkir; Hakan Terzioglu

    2012-01-01

    Objectives: Biomechanics is one of the main factors for achieving long-term success of implant supported prostheses. Long-term failures mostly depend on biomechanical complications. It is important to distinguish the effects of macro design of the implants. Materials and Methods: In this study, the photoelastic response of four different types of implants that were inserted with different angulations were comparatively analyzed. The implant types investigated were screw cylinder (ITI, Str...

  14. Complication incidence of two implant systems up to six years: a comparison between internal and external connection implants.

    Science.gov (United States)

    Chae, Sung-Wook; Kim, Young-Sung; Lee, Yong-Moo; Kim, Won-Kyung; Lee, Young-Kyoo; Kim, Su-Hwan

    2015-02-01

    This study was conducted to compare the cumulative survival rates (CSRs) and the incidence of postloading complications (PLCs) between a bone-level internal connection system (ICS-BL) and an external connection system (ECS). The medical records of patients treated with either a ICS-BL or ECS between 2007 and 2010 at Asan Medical Center were reviewed. PLCs were divided into two categories: biological and technical. Biological complications included >4 mm of probing pocket depth, thread exposure in radiographs, and soft tissue complications, whereas technical complications included chipping of the veneering material, fracture of the implant, fracture of the crown, loosening or fracture of the abutment or screw, loss of retention, and loss of access hole filling material. CSRs were determined by a life-table analysis and compared using the log-rank chi-square test. The incidence of PLC was compared with the Pearson chi-squared test. A total of 2,651 implants in 1,074 patients (1,167 ICS-BLs in 551 patients and 1,484 ECSs in 523 patients) were analyzed. The average observation periods were 3.4 years for the ICS-BLs and 3.1 years for the ECSs. The six-year CSR of all implants was 96.1% (94.9% for the ICS-BLs and 97.1% for the ECSs, P=0.619). Soft tissue complications were more frequent with the ECSs (P=0.005) and loosening or fracture of the abutment or screw occurred more frequently with the ICS-BLs (Plimitations of this study, the ICS-BL was more prone to technical complications while the ECS was more vulnerable to biological complications.

  15. Ion implantation methods for semiconductor substrates

    International Nuclear Information System (INIS)

    Matsushita, T.; Mamine, T.; Hayashi, H.; Nishiyama, K.

    1980-01-01

    A method of ion implantation for controlling the life time of minority carriers in a semiconductor substrate and hence to reduce the temperature dependency of the life time, comprises implanting iron ions into an N type semiconductor substrate with a dosage of 10 10 to 10 15 ions cm -2 , and then heat-treating the implanted substrate at 850 0 to 1250 0 C. The method is applicable to the production of diodes, transistors, Si controlled rectifiers and gate controlled switching devices. (author)

  16. A biomechanical testing system to determine micromotion between hip implant and femur accounting for deformation of the hip implant: Assessment of the influence of rigid body assumptions on micromotions measurements.

    Science.gov (United States)

    Leuridan, Steven; Goossens, Quentin; Roosen, Jorg; Pastrav, Leonard; Denis, Kathleen; Mulier, Michiel; Desmet, Wim; Vander Sloten, Jos

    2017-02-01

    Accurate pre-clinical evaluation of the initial stability of new cementless hip stems using in vitro micromotion measurements is an important step in the design process to assess the new stem's potential. Several measuring systems, linear variable displacement transducer-based and other, require assuming bone or implant to be rigid to obtain micromotion values or to calculate derived quantities such as relative implant tilting. An alternative linear variable displacement transducer-based measuring system not requiring a rigid body assumption was developed in this study. The system combined advantages of local unidirectional and frame-and-bracket micromotion measuring concepts. The influence and possible errors that would be made by adopting a rigid body assumption were quantified. Furthermore, as the system allowed emulating local unidirectional and frame-and-bracket systems, the influence of adopting rigid body assumptions were also analyzed for both concepts. Synthetic and embalmed bone models were tested in combination with primary and revision implants. Single-legged stance phase loading was applied to the implant - bone constructs. Adopting a rigid body assumption resulted in an overestimation of mediolateral micromotion of up to 49.7μm at more distal measuring locations. Maximal average relative rotational motion was overestimated by 0.12° around the anteroposterior axis. Frontal and sagittal tilting calculations based on a unidirectional measuring concept underestimated the true tilting by an order of magnitude. Non-rigid behavior is a factor that should not be dismissed in micromotion stability evaluations of primary and revision femoral implants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Effects of Repeated Screw Tightening on Implant Abutment Interfaces in Terms of Bacterial and Yeast Leakage in Vitro: One-Time Abutment Versus the Multiscrewing Technique.

    Science.gov (United States)

    Calcaterra, Roberta; Di Girolamo, Michele; Mirisola, Concetta; Baggi, Luigi

    2016-01-01

    Screw loosening can damage the interfaces of implant components, resulting in susceptibility to contamination of the internal parts by microorganisms. The aim of this study was to investigate the impact of abutment screw retightening on the leakage of two different types of bacteria, Streptococcus sanguinis and Fusobacterium nucleatum, and of the yeast Candida albicans. Two types of implant-abutment systems with tube-in-tube interfaces were tested. Groups A and B each used a different type of system that consisted of 20 different pieces that were assembled according to the manufacturer's torque recommendations; four samples in each group were closed just one time, four samples three times, four samples five times, four samples seven times, and four samples nine times. The implants of groups A and B were contaminated with 0.1 μL of microbial solution just before being assembled for the last time to minimize the possibility of contamination. Results showed a direct correlation between the number of colony-forming units grown in the plates and the closing/opening cycles of the implant-abutment systems. Within the limitations of this study, the results indicate the possibility that repeated closing/opening cycles of the implant-abutment unit may influence bacterial/yeast leakage, most likely as a consequence of decreased precision of the coupling between the abutment and the internal part of the dental implant. These findings suggest that a one-time abutment technique may avoid microbiologic leakage in cases of implant-abutment systems with tube-in-tube interfaces.

  18. Soft tissue around three different implant types after 1.5 years of functional loading without oral hygiene: a preliminary study in baboons.

    Science.gov (United States)

    Watzak, Georg; Zechner, Werner; Tangl, Stefan; Vasak, Christoph; Donath, Karl; Watzek, Georg

    2006-04-01

    The purpose of this study was to determine the peri-implant soft tissue dimension (PSD) and peri-implant bone level (BL) of dental implants with different designs and surface modifications after functional loading without oral hygiene. Three types of dental implants were placed in the posterior jaws of adult baboons, three of the same design per quadrant, and fitted with fixed partial dentures. After 1.5 years of functional loading and plaque accumulation, all implants showed severe peri-implant mucositis and comparatively high BL. A histomorphometric evaluation of the sulcus depth (SD), the dimension of the junctional epithelium (JE) and the connective tissue contact (CTC) resulted in no significant differences between the three implant designs, neither in the maxilla nor in the mandible (P>0.05). The sum of SD, JE and CTC forming the PSD was nearly the same in the maxilla (commercially pure titanium, CpTi: 3.5 mm 2.9/4.1 confidence interval (CI); titanium plasma sprayed (TPS): 3.5 mm 2.9/4.2 CI; sand blasted acid-etched (GBAE): 3.2 mm 2.7/3.9 CI) and in the mandible (CpTi: 3.2 mm 2.6/3.8 CI; TPS: 3.2 mm 2.6/3.8 CI; GBAE: 3.2 mm 2.7/3.9 CI; P>0.05). There was no difference in BL around the three implant designs (maxilla: CpTi: 0.9 mm 0.5/1.6 CI; TPS: 0.9 mm 0.5/1.5CI; GBAE: 0.9 mm 0.5/1.6 CI; mandible: CpTi: 0.8 mm 0.5/1.2 CI; TPS: 0.6 mm 0.4/0.9 CI; GBAE: 0.7 mm 0.5/1.1 CI; P>0.05). Overall, the data presented did not show any significant differences in peri-implant soft tissue conditions in baboons. Moreover, plaque accumulation and propagation of peri-implant mucositis after 1.5 years of functional loading was not influenced by implant design and surface modifications in baboons.

  19. Ion beam system for implanting industrial products of various shapes

    International Nuclear Information System (INIS)

    Denholm, A.S.; Wittkower, A.

    1985-01-01

    Implantation of metals and ceramics with ions of nitrogen and other species has improved surface properties such as friction, wear and corrosion in numerous industrial applications. Zymet has built a production machine to take advantage of this process which can implant a 2 x 10 17 ions/cm 2 dose of nitrogen ions into a 20 cm x 20 cm area in about 30 min using a 100 keV beam. Treatment is accomplished by mounting the product on a cooled, tiltable, turntable which rotates continuously, or is indexed in 15 0 steps to expose different surfaces in fixed position. Product cooling is accomplished by using a chilled eutectic metal to mount and grip the variously shaped objects. A high voltage supply capable of 10 mA at 100 kV is used, and the equipment is microcomputer controlled via serial light links. All important machine parameters are presented in sequenced displays on a CRT. Uniformity of treatment and accumulated dose are monitored by a Faraday cup system which provides the microprocessor with data for display of time to completion on the process screen. For routine implants the operator requires only two buttons; one for chamber vacuum control, and the other for process start and stop. (orig.)

  20. Implementation of wireless power transfer and communications for an implantable ocular drug delivery system.

    Science.gov (United States)

    Tang, T B; Smith, S; Flynn, B W; Stevenson, J T M; Gundlach, A M; Reekie, H M; Murray, A F; Renshaw, D; Dhillon, B; Ohtori, A; Inoue, Y; Terry, J G; Walton, A J

    2008-09-01

    A wireless power transfer and communication system based on near-field inductive coupling has been designed and implemented. The feasibility of using such a system to remotely control drug release from an implantable drug delivery system is addressed. The architecture of the wireless system is described and the signal attenuation over distance in both water and phosphate buffered saline is studied. Additionally, the health risk due to exposure to radio frequency (RF) radiation is examined using a biological model. The experimental results demonstrate that the system can trigger the release of drug within 5 s, and that such short exposure to RF radiation does not produce any significant (system could replace a chemical battery in an implantable system, eliminating the risks associated with battery failure and leakage and also allowing more compact designs for applications such as drug delivery.

  1. Imaging of implants on chest radiographs: a radiological perspective

    International Nuclear Information System (INIS)

    Burney, K.; Thayur, N.; Husain, S.A.; Martin, R.P.; Wilde, P.

    2007-01-01

    Endovascular and percutaneous techniques have emerged as alternatives to surgical management in the treatment for a wide range of congenital and acquired cardiac, non-vascular and vascular conditions. Consequently, there has been an increasing use of implants such as closure devices, vascular stents (coronary, aortic, pulmonary and superior vena cava) and non-vascular stents like oesophageal and tracheo-bronchial stents. A large number of percutaneously sited implants are used for treating congenital cardiac anomalies such as atrial septal defects (ASD), ventricular septal defects (VSD), and patent ductus arteriosus (PDA). These implants take many shapes and forms. The aim of this review is to demonstrate the radiographic appearances of the various types of cardiovascular, bronchial and oesophageal implants that are visible on plain films. A brief outline of the aims and indications of various implant procedures, the general appearance of the commonest types of implants, and the radiological procedures are discussed. All radiologists are likely to come across implanted devices in plain film reporting. Imaging can be useful in identifying the device, assessing the position, integrity, and for the identification of complications related directly to the implant

  2. Imaging of implants on chest radiographs: a radiological perspective

    Energy Technology Data Exchange (ETDEWEB)

    Burney, K [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom); Thayur, N [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom); Husain, S A [Department of Respiratory Medicine, Bristol Royal Infirmary (United Kingdom); Martin, R P [Department of Cardiology, Bristol Royal Hospital for Children, Bristol (United Kingdom); Wilde, P [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom)

    2007-03-15

    Endovascular and percutaneous techniques have emerged as alternatives to surgical management in the treatment for a wide range of congenital and acquired cardiac, non-vascular and vascular conditions. Consequently, there has been an increasing use of implants such as closure devices, vascular stents (coronary, aortic, pulmonary and superior vena cava) and non-vascular stents like oesophageal and tracheo-bronchial stents. A large number of percutaneously sited implants are used for treating congenital cardiac anomalies such as atrial septal defects (ASD), ventricular septal defects (VSD), and patent ductus arteriosus (PDA). These implants take many shapes and forms. The aim of this review is to demonstrate the radiographic appearances of the various types of cardiovascular, bronchial and oesophageal implants that are visible on plain films. A brief outline of the aims and indications of various implant procedures, the general appearance of the commonest types of implants, and the radiological procedures are discussed. All radiologists are likely to come across implanted devices in plain film reporting. Imaging can be useful in identifying the device, assessing the position, integrity, and for the identification of complications related directly to the implant.

  3. Wear properties of metal ion implanted 4140 steel

    International Nuclear Information System (INIS)

    Evans, P.J.; Paoloni, F.J.

    1994-01-01

    AISI type 4140 (high tensile) steel has been implanted with tungsten and titanium using a metal vapour vacuum arc ion source. Doses in the range (1-5)x10 16 ionscm -2 were implanted to a depth of approximately 30nm. The relative wear resistance between non-implanted and implanted specimens has been estimated using pin-on-disc and abrasive wear tests. Implantation of titanium decreased the area of wear tracks by a factor of 5 over unimplanted steel. In some cases the steel was also hardened by a liquid carburization treatment before implantation. Abrasion tests revealed a further improvement in wear resistance on this material following ion irradiation. ((orig.))

  4. Location of unaccessible implant surface areas during debridement in simulated peri-implantitis therapy

    OpenAIRE

    Steiger-Ronay, Valerie; Merlini, Andrea; Wiedemeier, Daniel B.; Schmidlin, Patrick R.; Attin, Thomas; Sahrmann, Philipp

    2017-01-01

    Background An in vitro model for peri-implantitis treatment was used to identify areas that are clinically difficult to clean by analyzing the pattern of residual stain after debridement with commonly employed instruments. Methods Original data from two previous publications, which simulated surgical (SA) and non-surgical (NSA) implant debridement on two different implant systems respectively, were reanalyzed regarding the localization pattern of residual stains after instrumentation. Two bli...

  5. Electromagnetic Interference in Patients with Implanted Cardioverter-Defibrillators and Implantable Loop Recorders

    Directory of Open Access Journals (Sweden)

    Marcos de Sousa

    2002-07-01

    Full Text Available Modern life exposes us all to an ever-increasing number of potential sources of electromagnetic interference (EMI and patients with Implantable rhythm devices (IRD like pacemakers, implantable cardioverter defibrillators or implantable loop recorders often ask about the use of microwave ovens, walking through airport metal detectors and the use of cellular phones. Electromagnetic interference occurs when electromagnetic waves emitted by one device impede the normal function of another electronic device. The potential for interaction between implanted pacing systems and cardioverter-defibrillators (electromagnetic interference, EMI has been recognized for years.1,2,3,4. It has been shown that EMI can produce clinically significant effects on patients with implanted pacemakers and ICDs. For these reasons the following text discusses the influence of several EMI generating devices on IRD .

  6. Influence of extracellular matrix coatings on implant stability and osseointegration: an animal study.

    Science.gov (United States)

    Stadlinger, Bernd; Pilling, Eckart; Huhle, Matthias; Mai, Ronald; Bierbaum, Susanne; Bernhardt, Ricardo; Scharnweber, Dieter; Kuhlisch, Eberhard; Hempel, Ute; Eckelt, Uwe

    2007-10-01

    Aim of the present study was to test the hypothesis that the application of components of the extracellular matrix such as glycosaminoglycans used as implant surface coatings in combination with collagen, with and without growth factor, can lead to enhanced ossification and thus improve implant stability compared with collagen coatings alone. Twenty miniature pigs received 120 experimental titanium implants in the mandible. Three types of surface coatings were created: (1) collagen type I (coll), (2) collagen type I/chondroitin sulphate (coll/CS), (3) collagen type I/chondroitin sulphate/BMP-4 (coll/CS/BMP). Periimplant bone formation was assessed within a defined recess along the length axis of the implant. Bone-implant contact (BIC) and bone volume density (BVD) were determined, using both histomorphometry and synchrotron radiation micro computed tomography (SRmicroCT). To measure implant stability, resonance frequency analysis was applied after implantation and 1, 3, 7, and 22 weeks after placement. BIC was highest for coll/CS coated implants, followed by coll, p = 0.082. Histomorphometric BVD did not significantly change for any coating. SRmicroCT analysis showed an increased BVD for collagen coated implants, compared with the other two surface coatings. Implant stability showed a decrease for all coatings up to the third week. At 22 weeks, all coatings showed an increase in stability without reaching their initial level. Highest stability was reached for coll coated implants, p = 0.051. It was concluded that collagen and coll/CS implant coatings have advantageous characteristics for peri-implant bone formation, compared with the further integration of BMP-4.

  7. Micro-computerised tomography optimisation for the measurement of bone mineral density around titanium dental implants

    International Nuclear Information System (INIS)

    Park, C.; Swain, M.; Duncan, W.

    2010-01-01

    Titanium dental implants (screws) are commonly used to replace missing teeth by forming a biological union with bone ('osseointegration'). Micro-computerised tomography (μCT) may be useful for measuring bone mineral density around dental implants. Major issues arise because of various artefacts that occur with polychromatic X-rays associated bench type instruments that may compromise interpretation of the observations. In this study various approaches to minimise artefacts such as; beam hardening, filtering and edge effects are explored with a homogeneous polymeric material, Teflon, with and without an implant present. The implications of the limitations of using such polychromatic μCT systems to quantify bone mineral density adjacent to the implant are discussed. (author)

  8. Pacemakers and implantable cardioverter defibrillators - general and anesthetic considerations

    Directory of Open Access Journals (Sweden)

    Amy G. Rapsang

    2014-06-01

    Full Text Available A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia, special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary.

  9. Immediate implant-supported oral rehabilitation using a photocurable plastic skull model and laser welding. A technical note on the screw-retained type: Part 1.

    Science.gov (United States)

    Tomotake, Yoritoki; Ishida, Osamu; Kanitani, Hideo; Ichikawa, Tetsuo

    2002-01-01

    This article describes a new procedure for immediate implant-supported oral rehabilitation using a photocurable resin skull model and a laser-welding apparatus. Preoperatively, the framework was fabricated on a photocurable resin skull model produced from a CT scan and individually designed guide template. The implants were immediately placed using the guide template; laser welding connected the components of framework. Despite the custom-made prosthesis, the total treatment from implant placement to superstructure placement can be completed within only 1 day. This procedure for immediate implant-supported oral rehabilitation using a photocurable resin skull model and a laser-welding apparatus may be useful for any implant system and patient.

  10. Description of the condition of the implant-prosthesis system: a transverse study

    International Nuclear Information System (INIS)

    Salazar Salgado, Walter

    2008-01-01

    Current condition of the implant-prosthesis system of the patients attended in the Facultad de Odontologia de la Universidad de Costa Rica is described, in the included period from January 2001 to December 2006. Parameters of comparison will be established for future evaluations. An appointment was scheduled with each patient to review. A radiovisiograph was used for digital radiography with parallel technique and radiographic positioners, for anterior and posterior sector. In addition, a questionnaire was applied to all patients. The percentage of survival of the implants placed in the years 2001-2006, is 95.2 % and 92.4 % of the patients are satisfied with the aesthetic aspect of their restoration [es

  11. Accuracy of two digital implant impression systems based on confocal microscopy with variations in customized software and clinical parameters.

    Science.gov (United States)

    Giménez, Beatriz; Pradíes, Guillermo; Martínez-Rus, Francisco; Özcan, Mutlu

    2015-01-01

    To evaluate the accuracy of two digital impression systems based on the same technology but different postprocessing correction modes of customized software, with consideration of several clinical parameters. A maxillary master model with six implants located in the second molar, second premolar, and lateral incisor positions was fitted with six cylindrical scan bodies. Scan bodies were placed at different angulations or depths apical to the gingiva. Two experienced and two inexperienced operators performed scans with either 3D Progress (MHT) or ZFX Intrascan (Zimmer Dental). Five different distances between implants (scan bodies) were measured, yielding five data points per impression and 100 per impression system. Measurements made with a high-accuracy three-dimensional coordinate measuring machine (CMM) of the master model acted as the true values. The values obtained from the digital impressions were subtracted from the CMM values to identify the deviations. The differences between experienced and inexperienced operators and implant angulation and depth were compared statistically. Experience of the operator, implant angulation, and implant depth were not associated with significant differences in deviation from the true values with both 3D Progress and ZFX Intrascan. Accuracy in the first scanned quadrant was significantly better with 3D Progress, but ZFX Intrascan presented better accuracy in the full arch. Neither of the two systems tested would be suitable for digital impression of multiple-implant prostheses. Because of the errors, further development of both systems is required.

  12. Influence of Implant Positions and Occlusal Forces on Peri-Implant Bone Stress in Mandibular Two-Implant Overdentures: A 3-Dimensional Finite Element Analysis.

    Science.gov (United States)

    Alvarez-Arenal, Angel; Gonzalez-Gonzalez, Ignacio; deLlanos-Lanchares, Hector; Brizuela-Velasco, Aritza; Dds, Elena Martin-Fernandez; Ellacuria-Echebarria, Joseba

    2017-12-01

    The aim of this study was to evaluate and compare the bone stress around implants in mandibular 2-implant overdentures depending on the implant location and different loading conditions. Four 3-dimensional finite element models simulating a mandibular 2-implant overdenture and a Locator attachment system were designed. The implants were located at the lateral incisor, canine, second premolar, and crossed-implant levels. A 150 N unilateral and bilateral vertical load of different location was applied, as was 40 N when combined with midline load. Data for von Mises stress were produced numerically, color coded, and compared between the models for peri-implant bone and loading conditions. With unilateral loading, in all 4 models much higher peri-implant bone stress values were recorded on the load side compared with the no-load side, while with bilateral occlusal loading, the stress distribution was similar on both sides. In all models, the posterior unilateral load showed the highest stress, which decreased as the load was applied more mesially. In general, the best biomechanical environment in the peri-implant bone was found in the model with implants at premolar level. In the crossed-implant model, the load side greatly altered the biomechanical environment. Overall, the overdenture with implants at second premolar level should be the chosen design, regardless of where the load is applied. The occlusal loading application site influences the bone stress around the implant. Bilateral occlusal loading distributes the peri-implant bone stress symmetrically, while unilateral loading increases it greatly on the load side, no matter where the implants are located.

  13. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.

    Science.gov (United States)

    Kandemir, Utku; Augat, Peter; Konowalczyk, Stefanie; Wipf, Felix; von Oldenburg, Geert; Schmidt, Ulf

    2017-08-01

    To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. Using the

  14. A simple ion implantation system for solar cells

    International Nuclear Information System (INIS)

    Kenny, M.J.; Bird, J.R.; Broe, H.G.

    1982-11-01

    A project has been initiated to investigate simple but effective ion implantation and pulsed annealing techniques for the fabrication of high efficiency silicon solar cells. In particular, the method aims to eliminate the mass analyser and associated components from the implanter. A solid feed source is used in a clean ultra high vacuum environment to minimise impurities

  15. Localization and Tracking of Implantable Biomedical Sensors

    Directory of Open Access Journals (Sweden)

    Ilknur Umay

    2017-03-01

    Full Text Available Implantable sensor systems are effective tools for biomedical diagnosis, visualization and treatment of various health conditions, attracting the interest of researchers, as well as healthcare practitioners. These systems efficiently and conveniently provide essential data of the body part being diagnosed, such as gastrointestinal (temperature, pH, pressure parameter values, blood glucose and pressure levels and electrocardiogram data. Such data are first transmitted from the implantable sensor units to an external receiver node or network and then to a central monitoring and control (computer unit for analysis, diagnosis and/or treatment. Implantable sensor units are typically in the form of mobile microrobotic capsules or implanted stationary (body-fixed units. In particular, capsule-based systems have attracted significant research interest recently, with a variety of applications, including endoscopy, microsurgery, drug delivery and biopsy. In such implantable sensor systems, one of the most challenging problems is the accurate localization and tracking of the microrobotic sensor unit (e.g., robotic capsule inside the human body. This article presents a literature review of the existing localization and tracking techniques for robotic implantable sensor systems with their merits and limitations and possible solutions of the proposed localization methods. The article also provides a brief discussion on the connection and cooperation of such techniques with wearable biomedical sensor systems.

  16. Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions.

    Science.gov (United States)

    Bosshardt, Dieter D; Chappuis, Vivianne; Buser, Daniel

    2017-02-01

    Bone healing around dental implants follows the pattern and sequence of intramembraneous osteogenesis with formation of woven bone first of all followed later by formation of parallel-fibered and lamellar bone. Bone apposition onto the implant surface starts earlier in trabecular bone than in compact bone. While the first new bone may be found on the implant surface around 1 week after installation, bone remodeling starts at between 6 and 12 weeks and continues throughout life. Bone remodeling also involves the bone-implant interface, thus transiently exposing portions of the implant surface. Surface modifications creating micro-rough implant surfaces accelerate the osseointegration process of titanium implants, as demonstrated in numerous animal experiments. Sandblasting followed by acid-etching may currently be regarded as the gold standard technique to create micro-rough surfaces. Chemical surface modifications, resulting in higher hydrophilicity, further increase the speed of osseointegration of titanium and titanium-zirconium implants in both animals and humans. Surface modifications of zirconia and alumina-toughened zirconia implants also have an influence on the speed of osseointegration, and some implant types reach high bone-to-implant contact values in animals. Although often discussed independently of each other, surface characteristics, such as topography and chemistry, are virtually inseparable. Contemporary, well-documented implant systems with micro-rough implant surfaces, placed by properly trained and experienced clinicians, demonstrate high long-term survival rates. Nevertheless, implant failures do occur. A low percentage of implants are diagnosed with peri-implantitis after 10 years in function. In addition, a low number of implants seem to be lost for primarily reasons other than biofilm-induced infection. Patient factors, such as medications interfering with the immune system and bone cells, may be an element contributing to continuous bone

  17. A detection system for charged-particle decay studies with a continuous-implantation method

    Energy Technology Data Exchange (ETDEWEB)

    Sun, L.J. [China Institute of Atomic Energy, Beijing 102413 (China); Xu, X.X., E-mail: xuxinxing@ciae.ac.cn [China Institute of Atomic Energy, Beijing 102413 (China); Lin, C.J., E-mail: cjlin@ciae.ac.cn [China Institute of Atomic Energy, Beijing 102413 (China); Wang, J.S. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Fang, D.Q. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Li, Z.H. [School of Physic and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Wang, Y.T. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Li, J. [School of Physic and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Yang, L.; Ma, N.R. [China Institute of Atomic Energy, Beijing 102413 (China); Wang, K. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Zang, H.L. [School of Physic and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Wang, H.W.; Li, C.; Shi, C.Z.; Nie, M.W.; Li, X.F.; Li, H. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Ma, J.B.; Ma, P. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); and others

    2015-12-21

    A new detection system with high detection efficiency and low detection threshold has been developed for charged-particle decay studies, including β-delayed proton, α decay or direct proton emission from proton-rich nuclei. The performance was evaluated by using the β-delayed proton emitter {sup 24}Si produced by projectile fragmentation at the First Radioactive Ion Beam Line in Lanzhou. Under a continuous-beam mode, the isotopes of interest were implanted into two double-sided silicon strip detectors, where the subsequent decays were measured and correlated to the preceding implantations by using position and time information. The system allows us to measure protons with energies down to about 200 keV without obvious β background in the proton spectrum. Further application of the detection system can be extended to the measurements of β-delayed proton decay and the direct proton emission of more exotic proton-rich nuclei.

  18. 21 CFR 880.6300 - Implantable radiofrequency transponder system for patient identification and health information.

    Science.gov (United States)

    2010-04-01

    ... patient identification and health information. 880.6300 Section 880.6300 Food and Drugs FOOD AND DRUG... radiofrequency transponder system for patient identification and health information. (a) Identification. An implantable radiofrequency transponder system for patient identification and health information is a device...

  19. Wear properties of metal ion implanted 4140 steel

    Energy Technology Data Exchange (ETDEWEB)

    Evans, P.J. (Applications of Nuclear Physics, Ansto, Private Mail Bag 1, Menai, NSW 2234 (Australia)); Paoloni, F.J. (Department of Electrical and Computer Engineering, University of Wollongong, GPO Box 1144, Wollongong, NSW 2500 (Australia))

    1994-07-01

    AISI type 4140 (high tensile) steel has been implanted with tungsten and titanium using a metal vapour vacuum arc ion source. Doses in the range (1-5)x10[sup 16]ionscm[sup -2] were implanted to a depth of approximately 30nm. The relative wear resistance between non-implanted and implanted specimens has been estimated using pin-on-disc and abrasive wear tests. Implantation of titanium decreased the area of wear tracks by a factor of 5 over unimplanted steel. In some cases the steel was also hardened by a liquid carburization treatment before implantation. Abrasion tests revealed a further improvement in wear resistance on this material following ion irradiation. ((orig.))

  20. Augmentation Mammaplasty Using Implants: A Review

    Directory of Open Access Journals (Sweden)

    Susumu Takayanagi

    2012-09-01

    Full Text Available One of the techniques for augmentation mammaplasty is the procedure using implants. Eventhough this technique has been used for many years, there are still several controversial issuesto be discussed and overcome for patient safety. In this review article, capsular contracture,leak or rupture of the implants, possible systemic disease, relation with breast cancer, andrecent problems with Poly Implant Prothese implants are described and discussed.

  1. Immune responses to implanted human collagen graft in rats

    International Nuclear Information System (INIS)

    Quteish, D.; Dolby, A.E.

    1991-01-01

    Immunity to collagen implants may be mediated by cellular and humoral immune responses. To examine the possibility of such immunological reactivity and crossreactivity to collagen, 39 Sprague-Dawley rats (female, 10 weeks old, approximately 250 g wt) were implanted subcutaneously at thigh sites with crosslinked, freeze-dried human placental type I collagen grafts (4x4x2 mm) which had been irradiated (520 Gray) or left untreated. Blood was obtained by intracardiac sampling prior to implantation or from normal rats, and at various times afterwards when the animals were sacrificed. The sera from these animals were examined for circulating antibodies to human, bovine and rat tail (type I) collagens by enzyme-linked immunosorbent assay (ELISA). Also, the lymphoblastogenic responses of spleen lymphocytes from the irradiated collagen-implanted animals were assessed in culture by measuring thymidine uptake with autologous and normal rat sera in the presence of human bovine type I collagens. Implantation of the irradiated and non-irradiated collagen graft in rats led to a significant increase in the level of circulating antibodies to human collagen. Also antibody to bovine and rat tail collagens was detectable in the animals implanted with irradiated collagen grafts but at a lower level than the human collagen. There was a raised lymphoblastogenic response to both human and bovine collagens. The antibody level and lymphoblastogenesis to the tested collagens gradually decreased towards the end of the post-implantation period. (author)

  2. The effect of implant macro-thread design on implant stability in the early post-operative period: a randomized, controlled pilot study.

    Science.gov (United States)

    McCullough, Jeffrey J; Klokkevold, Perry R

    2017-10-01

    Available literature suggests there is a transient drop in implant stability from approximately week 0 to week 3-4 as a result of peri-implant bone remodeling as it transitions from a primary, mechanical stability to a secondary, biological stability. Research investigating the influence of macro-thread design on this process is scant. The specific aim of this study was to evaluate the role of macro-thread design on implant stability in the early post-operative healing period using resonance frequency analysis (RFA). Seven patients, each missing at least two posterior teeth in the same arch, were included in the study. Three patients qualified for four implants resulting in a total of 10 matched pairs. All sites were healed (>6 months), non-grafted sites with sufficient bone to place implants. Each site in a matched pair was randomly assigned to receive either a control (Megagen EZ Plus Internal; EZ) or test (Megagen AnyRidge; AR) implant. The test implant incorporates a novel thread design with a wide thread depth and increased thread pitch. RFA was used to determine implant stability quotient (ISQ) values for each implant at the time of placement and weekly for the first 8 weeks. Implants consistently achieved a relatively high insertion torque (30-45 N/cm) and high initial ISQ value (79.8 ± 1.49). Baseline ISQ values for test (AR; 79.55 ± 1.61) and control (EZ; 80.05 ± 1.37) implants were similar. A general pattern of stability from baseline through all eight follow-up evaluations was observed for the test implants. A pattern of decreasing ISQ values was observed for the control implants across the early follow-up evaluations up to week four, where the value plateaued. There was a statistically significant main effect due to implant type (P implant type and time (P implants performed differently at certain time points. Within the limitations of this study, macro-thread design appears to play a role in implant stability in the early post

  3. Bone attachment to glass-fibre-reinforced composite implant with porous surface.

    Science.gov (United States)

    Mattila, R H; Laurila, P; Rekola, J; Gunn, J; Lassila, L V J; Mäntylä, T; Aho, A J; Vallittu, P K

    2009-06-01

    A method has recently been developed for producing fibre-reinforced composites (FRC) with porous surfaces, intended for use as load-bearing orthopaedic implants. This study focuses on evaluation of the bone-bonding behaviour of FRC implants. Three types of cylindrical implants, i.e. FRC implants with a porous surface, solid polymethyl methacrylate (PMMA) implants and titanium (Ti) implants, were inserted in a transverse direction into the intercondular trabeculous bone area of distal femurs and proximal tibias of New Zealand White rabbits. Animals were sacrificed at 3, 6 and 12 weeks post operation, and push-out tests (n=5-6 per implant type per time point) were then carried out. At 12 weeks the shear force at the porous FRC-bone interface was significantly higher (283.3+/-55.3N) than the shear force at interfaces of solid PMMA/bone (14.4+/-11.0 N; pshielding effect.

  4. Mutagenic effects of endosperm of triticum aestivum implanted by heavy ion beams

    International Nuclear Information System (INIS)

    Xie Hongmei; Li Xinglin; Wei Zengquan; Xie Zhongkui

    2004-01-01

    75 MeV/u 16 O 8+ ions (degraded to 36 MeV/u) were used to implant into endosperm about 2.4 mm on top of the seeds. Germination started after a 'grafting' technique was employed. Chromosomal aberration frequency and micronucleus frequency of the root-tip cells in M 0 were measured. The results indicate that the frequencies were proportional to implanted dose. Antioxidant enzyme activity, MDA content and protein content of present generation M 0 were assayed. Farm culture was carried out in many generations. Short-stem and various variation of ear-type were obtained and the variation possess heredity. It showed that the endosperm implanted by the ions not only affected biological repair system, but also induced the mutation of offspring

  5. Comparison of the impact of scaler material composition on polished titanium implant abutment surfaces.

    Science.gov (United States)

    Hasturk, Hatice; Nguyen, Daniel Huy; Sherzai, Homa; Song, Xiaoping; Soukos, Nikos; Bidlack, Felicitas B; Van Dyke, Thomas E

    2013-08-01

    The purpose of this study was to compare the impact of the removal of biofilm with hand scalers of different material composition on the surface of implant abutments by assessing the surface topography and residual plaque after scaling using scanning electron microscopy (SEM). Titanium implant analogs from 3 manufacturers (Straumann USA LLC, Andover, Maine, Nobel BioCare USA LLC, Yorba Linda, Cali, Astra Tech Implant Systems, Dentsply, Mölndal, Sweden) were mounted in stone in plastic vials individually with authentic prosthetic abutments. Plaque samples were collected from a healthy volunteer, inoculated into growth medium and incubated with the abutments anaerobically for 1 week. A blinded, calibrated hygienist performed scaling to remove the biofilm using 6 implant scalers (in triplicate), 1 scaler for 1 abutment. The abutments were mounted on an imaging stand and processed for SEM. Images were captured in 3 randomly designated areas of interest on each abutment. Analysis of the implant polished abutment surface and plaque area measurements were performed using ImageJ image analysis software. Surface alterations were characterized by the number, length, depth and the width of the scratches observed. Glass filled resin scalers resulted in significantly more and longer scratches on all 3 abutment types compared to other scalers, while unfilled resin scalers resulted in the least surface change (p abutments with regard to plaque removal. The impact of scalers on implant abutment surfaces varies between abutment types presumably due to different surface characteristics with no apparent advantage of one abutment type over the other with regard to resistance to surface damage. Unfilled resin was found consistently to be the least damaging to abutment surfaces, although all scalers of all compositions caused detectable surface changes to polished surfaces of implant abutments.

  6. Randomized study on the effect of single-implant versus two-implant retained overdentures on implant loss and muscle activity: a 12-month follow-up report.

    Science.gov (United States)

    Alqutaibi, A Y; Kaddah, A F; Farouk, M

    2017-06-01

    The objective was to evaluate and compare single- and two-implant retained overdentures for the rehabilitation of the edentulous mandible. Fifty-six edentulous subjects were eligible for inclusion. Using a random sampling system, a single implant or two implants were placed in the mandible. After 3 months, locator attachments were connected to the implants and the denture delivered with the retentive components incorporated in the denture base. Implant failure and muscle activity were evaluated at the 3-, 6-, and 12-month follow-up examinations. The study sample comprised 56 patients (32 male, 24 female), with a mean age of 58.2 years. A total of 84 implants were placed (28 in the single-implant group and 56 in the two-implant group). All patients completed the 12 months of follow-up. No significant differences were found between subjects in the two groups with respect to implant failure. With regard to improvements in muscle activity, the two-implant group showed statistically significant but perhaps not clinically important differences. Single-implant mandibular overdentures may be suggested as an alternative treatment modality for the rehabilitation of edentulous patients who cannot afford the cost of a two-implant overdenture. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Augmentation Mammaplasty Using Implants: A Review

    Directory of Open Access Journals (Sweden)

    Susumu Takayanagi

    2012-09-01

    Full Text Available One of the techniques for augmentation mammaplasty is the procedure using implants. Even though this technique has been used for many years, there are still several controversial issues to be discussed and overcome for patient safety. In this review article, capsular contracture, leak or rupture of the implants, possible systemic disease, relation with breast cancer, and recent problems with Poly Implant Prothese implants are described and discussed.

  8. Macro design effects on stress distribution around implants: A photoelastic stress analysis

    Directory of Open Access Journals (Sweden)

    Serhat Emre Ozkir

    2012-01-01

    Conclusion: As there were observable differences between the implant types, straight placed cylindrical implants showed better stress distribution characteristics, while inclined tapering implants had better stress distribution characteristics.

  9. Immunological Response to Biodegradable Magnesium Implants

    Science.gov (United States)

    Pichler, Karin; Fischerauer, Stefan; Ferlic, Peter; Martinelli, Elisabeth; Brezinsek, Hans-Peter; Uggowitzer, Peter J.; Löffler, Jörg F.; Weinberg, Annelie-Martina

    2014-04-01

    The use of biodegradable magnesium implants in pediatric trauma surgery would render surgical interventions for implant removal after tissue healing unnecessary, thereby preventing stress to the children and reducing therapy costs. In this study, we report on the immunological response to biodegradable magnesium implants—as an important aspect in evaluating biocompatibility—tested in a growing rat model. The focus of this study was to investigate the response of the innate immune system to either fast or slow degrading magnesium pins, which were implanted into the femoral bones of 5-week-old rats. The main alloying element of the fast-degrading alloy (ZX50) was Zn, while it was Y in the slow-degrading implant (WZ21). Our results demonstrate that degrading magnesium implants beneficially influence the immune system, especially in the first postoperative weeks but also during tissue healing and early bone remodeling. However, rodents with WZ21 pins showed a slightly decreased phagocytic ability during bone remodeling when the degradation rate reached its maximum. This may be due to the high release rate of the rare earth-element yttrium, which is potentially toxic. From our results we conclude that magnesium implants have a beneficial effect on the innate immune system but that there are some concerns regarding the use of yttrium-alloyed magnesium implants, especially in pediatric patients.

  10. A wirelessly controlled implantable LED system for deep brain optogenetic stimulation

    Science.gov (United States)

    Rossi, Mark A.; Go, Vinson; Murphy, Tracy; Fu, Quanhai; Morizio, James; Yin, Henry H.

    2015-01-01

    In recent years optogenetics has rapidly become an essential technique in neuroscience. Its temporal and spatial specificity, combined with efficacy in manipulating neuronal activity, are especially useful in studying the behavior of awake behaving animals. Conventional optogenetics, however, requires the use of lasers and optic fibers, which can place considerable restrictions on behavior. Here we combined a wirelessly controlled interface and small implantable light-emitting diode (LED) that allows flexible and precise placement of light source to illuminate any brain area. We tested this wireless LED system in vivo, in transgenic mice expressing channelrhodopsin-2 in striatonigral neurons expressing D1-like dopamine receptors. In all mice tested, we were able to elicit movements reliably. The frequency of twitches induced by high power stimulation is proportional to the frequency of stimulation. At lower power, contraversive turning was observed. Moreover, the implanted LED remains effective over 50 days after surgery, demonstrating the long-term stability of the light source. Our results show that the wireless LED system can be used to manipulate neural activity chronically in behaving mice without impeding natural movements. PMID:25713516

  11. [A totally implantable venous access device. Implantation in general or local anaesthesia? A retrospective cost analysis].

    Science.gov (United States)

    Schuld, J; Richter, S; Moussavian, M R; Kollmar, O; Schilling, M K

    2009-08-01

    Implantation of venous access port systems can be performed in local or general anesthesia. In spite of the increasing rate of interventionally implanted systems, the surgical cut-down represents a safe alternative. Thus, the question arises whether--in context to the increasing health-economic pressure--open implantation in general anesthesia is still a feasible alternative to implantation in local anesthesia regarding OR efficiency and costs. In a retrospective analysis, 993 patients receiving a totally implantable venous access device between 2001 and 2007 were evaluated regarding OR utilization, turnover times, intraoperative data and costs. Implantations in local (LA) and general anesthesia (GA) were compared. GA was performed in 762 cases (76.6 %), LA was performed in 231 patients (23.3 %). Mean operation time was similar in both groups (LA 47.27 +/- 1.40 min vs. GA 45.41 +/- 0.75 min, p = 0.244). Patients receiving local anesthesia had a significantly shorter stay in the OR unit (LA 95.9 +/- 1.78 min vs. GA 105.92 +/- 0.92 min; p cut (LA 39.57 +/- 0.69 min vs. GA 50.46 +/- 0.52 min; p material costs were significantly lower in the LA group compared with the GA group (LA: 400.72 +/- 8.25 euro vs. GA: 482.86 +/- 6.23 euro; p systems in local anesthesia is superior in comparison to the implantation under general anesthesia regarding procedural times in the OR unit and costs. With the same operation duration, but less personnel and material expenditure, implantation in local anesthesia offers a potential economic advantage by permitting faster changing times. Implantation in GA only should be performed at a special request by the patient or in difficult venous conditions. Georg Thieme Verlag Stuttgart.New York.

  12. Hydrogenation of stainless steels implanted with nitrogen

    International Nuclear Information System (INIS)

    Silva Ramos, L.E. da.

    1989-01-01

    In the present work the effects of both ion implantation and hydrogenation on the fatigue behaviour of an AISI-304 type unstable stainless steel was studied. The material was tested under the following microstructural conditions: annealed; annealed plus hydrogenated; annealed plus ion-implanted; annealed, ion-implanted and hydrogeneted. The hydrogen induced phase transformations were also studied during the outgassing of the samples. The ion implanted was observed to retard the kinetics of the hydrogen induced phase transformations. It was also observed that the nitrogen ion implantation followed by both natural (for about 4 months) and artificial (100 0 C for 6 hours) aging treatments was beneficial to the fatigue life of both non hydrogenated and severely hydrogenated samples. (author) [pt

  13. Fracture Resistance and Mode of Failure of Ceramic versus Titanium Implant Abutments and Single Implant-Supported Restorations.

    Science.gov (United States)

    Sghaireen, Mohd G

    2015-06-01

    The material of choice for implant-supported restorations is affected by esthetic requirements and type of abutment. This study compares the fracture resistance of different types of implant abutments and implant-supported restorations and their mode of failure. Forty-five Oraltronics Pitt-Easy implants (Oraltronics Dental Implant Technology GmbH, Bremen, Germany) (4 mm diameter, 10 mm length) were embedded in clear autopolymerizing acrylic resin. The implants were randomly divided into three groups, A, B and C, of 15 implants each. In group A, titanium abutments and metal-ceramic crowns were used. In group B, zirconia ceramic abutments and In-Ceram Alumina crowns were used. In group C, zirconia ceramic abutments and IPS Empress Esthetic crowns were used. Specimens were tested to failure by applying load at 130° from horizontal plane using an Instron Universal Testing Machine. Subsequently, the mode of failure of each specimen was identified. Fracture resistance was significantly different between groups (p Empress crowns supported by zirconia abutments had the lowest fracture loads (p = .000). Fracture modes of metal-ceramic crowns supported by titanium abutments included screw fracture and screw bending. Fracture of both crown and abutment was the dominant mode of failure of In-Ceram/IPS Empress crowns supported by zirconia abutments. Metal-ceramic crowns supported by titanium abutments were more resistant to fracture than In-Ceram crowns supported by zirconia abutments, which in turn were more resistant to fracture than IPS Empress crowns supported by zirconia abutments. In addition, failure modes of restorations supported by zirconia abutments were more catastrophic than those for restorations supported by titanium abutments. © 2013 Wiley Periodicals, Inc.

  14. A two-microphone noise reduction system for cochlear implant users with nearby microphones. Part II: Performance Evaluation

    OpenAIRE

    Kompis, Martin; Bertram, Matthias; Senn, Pascal; Müller, Joachim; Pelizzone, Marco; Häusler, Rudolf

    2008-01-01

    Users of cochlear implants (auditory aids, which stimulate the auditory nerve electrically at the inner ear) often suffer from poor speech understanding in noise. We evaluate a small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. The system is evaluated in simulated and real, anechoic and reverberant environments. Results from simulations show improvements of 3.4 to 9.3 dB in signa...

  15. An in vivo assessment of the effects of using different implant abutment occluding materials on implant microleakage and the peri-implant microbiome

    Science.gov (United States)

    Rubino, Caroline

    Microleakage may be a factor in the progression of peri-implant pathology. Microleakage in implant dentistry refers to the passage of bacteria, fluids, molecules or ions between the abutment-implant interface to and from the surrounding periodontal tissues. This creates a zone of inflammation and reservoir of bacteria at the implant-abutment interface. Bone loss typically occurs within the first year of abutment connection and then stabilizes. It has not yet been definitively proven that the occurrence of microleakage cannot contribute to future bone loss or impede the treatment of peri-implant disease. Therefore, strategies to reduce or eliminate microleakage are sought out. Recent evidence demonstrates that the type of implant abutment channel occluding material can affect the amount of microleakage in an in vitro study environment. Thus, we hypothesize that different abutment screw channel occluding materials will affect the amount of observed microleakage, vis-a-vis the correlation between the microflora found on the abutment screw channel occluding material those found in the peri-implant sulcus. Additional objectives include confirming the presence of microleakage in vivo and assessing any impact that different abutment screw channel occluding materials may have on the peri-implant microbiome. Finally, the present study provides an opportunity to further characterize the peri-implant microbiome. Eight fully edentulous patients restored with at dental implants supporting screw-retained fixed hybrid prostheses were included in the study. At the initial appointment (T1), the prostheses were removed and the implants and prostheses were cleaned. The prostheses were then inserted with polytetrafluoroethylene tape (PTFE, TeflonRTM), cotton, polyvinyl siloxane (PVS), or synthetic foam as the implant abutment channel occluding material and sealed over with composite resin. About six months later (T2), the prostheses were removed and the materials collected. Paper

  16. Sacroiliac joint stability: Finite element analysis of implant number, orientation, and superior implant length.

    Science.gov (United States)

    Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K

    2018-03-18

    To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System ® ). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results.

  17. Variable-temperature sample system for ion implantation at -192 to +5000C

    International Nuclear Information System (INIS)

    Fuller, C.T.

    1978-04-01

    A variable-temperature sample system based on exchange-gas coupling was developed for ion-implantation use. The sample temperature can be controlled from -192 0 C to +500 0 C with rapid cooling. The system also has provisions for focusing and alignment of the ion beam, electron suppression, temperature monitoring, sample current measuring, and cryo-shielding. Design considerations and operating characteristics are discussed. 5 figures

  18. Retrolabyrinthine approach for cochlear nerve preservation in neurofibromatosis type 2 and simultaneous cochlear implantation

    Directory of Open Access Journals (Sweden)

    Bento, Ricardo Ferreira

    2014-01-01

    Full Text Available Introduction: Few cases of cochlear implantation (CI in neurofibromatosis type 2 (NF2 patients had been reported in the literature. The approaches described were translabyrinthine, retrosigmoid or middle cranial fossa. Objectives: To describe a case of a NF2- deafened-patient who underwent to vestibular schwannoma resection via RLA with cochlear nerve preservation and CI through the round window, at the same surgical time. Resumed Report: A 36-year-old woman with severe bilateral hearing loss due to NF2 was submitted to vestibular schwannoma resection and simultaneous CI. Functional assessment of cochlear nerve was performed by electrical promontory stimulation. Complete tumor removal was accomplishment via RLA with anatomic and functional cochlear and facial nerve preservation. Cochlear electrode array was partially inserted via round window. Sound field hearing threshold improvement was achieved. Mean tonal threshold was 46.2 dB HL. The patient could only detect environmental sounds and human voice but cannot discriminate vowels, words nor do sentences at 2 years of follow-up. Conclusion: Cochlear implantation is a feasible auditory restoration option in NF2 when cochlear anatomic and functional nerve preservation is achieved. The RLA is adequate for this purpose and features as an option for hearing preservation in NF2 patients.

  19. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  20. Wear mechanisms in ceramic hip implants.

    Science.gov (United States)

    Slonaker, Matthew; Goswami, Tarun

    2004-01-01

    The wear in hip implants is one of the main causes for premature hip replacements. The wear affects the potential life of the prosthesis and subsequent removals of in vivo implants. Therefore, the objective of this article is to review various joints that show lower wear rates and consequently higher life. Ceramics are used in hip implants and have been found to produce lower wear rates. This article discusses the advantages and disadvantages of ceramics compared to other implant materials. Different types of ceramics that are being used are reviewed in terms of the wear characteristics, debris released, and their size together with other biological factors. In general, the wear rates in ceramics were lower than that of metal-on-metal and metal-on-polyethylene combinations.

  1. Optimization of dental implantation

    Science.gov (United States)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  2. Symmetric Encryption Relying on Chaotic Henon System for Secure Hardware-Friendly Wireless Communication of Implantable Medical Systems

    Directory of Open Access Journals (Sweden)

    Taha Belkhouja

    2018-05-01

    Full Text Available Healthcare remote devices are recognized as a promising technology for treating health related issues. Among them are the wireless Implantable Medical Devices (IMDs: These electronic devices are manufactured to treat, monitor, support or replace defected vital organs while being implanted in the human body. Thus, they play a critical role in healing and even saving lives. Current IMDs research trends concentrate on their medical reliability. However, deploying wireless technology in such applications without considering security measures may offer adversaries an easy way to compromise them. With the aim to secure these devices, we explore a new scheme that creates symmetric encryption keys to encrypt the wireless communication portion. We will rely on chaotic systems to obtain a synchronized Pseudo-Random key. The latter will be generated separately in the system in such a way that avoids a wireless key exchange, thus protecting patients from the key theft. Once the key is defined, a simple encryption system that we propose in this paper will be used. We analyze the performance of this system from a cryptographic point of view to ensure that it offers a better safety and protection for patients.

  3. The effect of implant number and position on the stress behavior of mandibular implant retained overdentures: A three-dimensional finite element analysis.

    Science.gov (United States)

    Topkaya, Tolga; Solmaz, Murat Yavuz

    2015-07-16

    The present study evaluated the effects of ball anchor abutment attached to implants with a 4.30 mm diameter and 11 mm insert length on stress distribution in a patient without any remaining teeth in the lower jaw. In the study, the stress analysis was performed for five different configurations (2 with 4 implant-supported and 3 with 2 implant-supported) and three different loading types using ANSYS Workbench software. The stresses measured in the 4 implant-supported models were lower compared to the stresses measured in the 2 implant-supported models. The stresses on the implants intensified on the cervical region of the implants. When the effects of the loading sites on the stress were examined, the loading on the first molar tooth produced the highest stresses on the implants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. An economic evaluation of maxillary implant overdentures based on six vs. four implants.

    Science.gov (United States)

    Listl, Stefan; Fischer, Leonhard; Giannakopoulos, Nikolaos Nikitas

    2014-08-18

    The purpose of the present study was to assess the value for money achieved by bar-retained implant overdentures based on six implants compared with four implants as treatment alternatives for the edentulous maxilla. A Markov decision tree model was constructed and populated with parameter estimates for implant and denture failure as well as patient-centred health outcomes as available from recent literature. The decision scenario was modelled within a ten year time horizon and relied on cost reimbursement regulations of the German health care system. The cost-effectiveness threshold was identified above which the six-implant solution is preferable over the four-implant solution. Uncertainties regarding input parameters were incorporated via one-way and probabilistic sensitivity analysis based on Monte-Carlo simulation. Within a base case scenario of average treatment complexity, the cost-effectiveness threshold was identified to be 17,564 € per year of denture satisfaction gained above of which the alternative with six implants is preferable over treatment including four implants. Sensitivity analysis yielded that, depending on the specification of model input parameters such as patients' denture satisfaction, the respective cost-effectiveness threshold varies substantially. The results of the present study suggest that bar-retained maxillary overdentures based on six implants provide better patient satisfaction than bar-retained overdentures based on four implants but are considerably more expensive. Final judgements about value for money require more comprehensive clinical evidence including patient-centred health outcomes.

  5. Troponin T elevation after permanent pacemaker implantation.

    Science.gov (United States)

    Chen, Xueying; Yu, Ziqing; Bai, Jin; Hu, Shulan; Wang, Wei; Qin, Shengmei; Wang, Jingfeng; Sun, Zhe; Su, Yangang; Ge, Junbo

    2017-08-01

    The objective of the study is to study the incidence, significance, and factors associated with cardiac troponin T (CTNT) elevation after pacemaker implantation. Three hundred seventy-four patients (104 single-chamber pacemakers or ICD, 243 dual-chamber pacemakers, and 27 cardiac resynchronization therapy/cardiac resynchronization therapy defibrillator) who had normal levels of CTNT at baseline and underwent implantation of a permanent pacemaker system were included in this study. Serum levels of CTNT were measured at baseline, 6 and 24 h after the implantation procedure. The median of CTNT levels increased from 0.012 ng/mL at baseline to 0.032 and 0.019 ng/mL at 6 and 24 h after the procedure, respectively (all p 0.09 ng/mL). After 1-year follow-up, the incidence of complications including dislodgement of the lead, pocket infection, pneumothorax, hemothorax, and vein thrombus and cardiac outcomes including hospitalization of heart failure, coronary artery disease, arrhythmia, and cardiovascular mortality was not significantly different between the normal and elevated CTNT groups at 6 h after the procedure. By logistic regression analysis, gender, N-terminal pro-B type natriuretic peptide (NT-pro-BNP) at baseline, left ventricular ejection fractions (LVEF), estimated glomerular filtration rate (eGFR), and fluoroscopy time were independently associated with CTNT elevation after adjusted for age, pacemaker types, right ventricle lead location (RVA or RVOT), heart function, and left ventricular end systolic dimension. Pacemaker implantation was found to be accompanied with CTNT elevation in 55.6% of the patients at 6 h after the procedure, and its kinetics were fast, which might not be related to the complications and adverse cardiac outcomes within 1 year of follow-up. Moreover, gender, NT-pro-BNP at baseline, LVEF, eGFR, and fluoroscopy time were found to be independent predictors of CTNT elevation.

  6. Evolving practices in augmentation operative technique with Sientra HSC round implants.

    Science.gov (United States)

    Calobrace, M Bradley; Kaufman, David L; Gordon, Ashley E; Reid, Dustin L

    2014-07-01

    As of 2012, breast augmentation surgery continues to be the most commonly performed aesthetic surgical procedure in the United States. Surgeons consider a multitude of factors when choosing the type and style of breast implant for a patient. With the continuous evolution of breast implant designs, there are a variety of breast implant options for plastic surgeons to choose from; however, round implants remain the implant of choice for breast augmentation. This article discusses preoperative planning, implant selection, surgical techniques, and postoperative management using Sientra's Silimed brand smooth and textured round implants.

  7. Three-Dimensional Electroanatomic Mapping System-Enhanced Cardiac Resynchronization Therapy Device Implantation: Results From a Multicenter Registry.

    Science.gov (United States)

    Del Greco, Maurizio; Maines, Massimiliano; Marini, Massimiliano; Colella, Andrea; Zecchin, Massimo; Vitali-Serdoz, Laura; Blandino, Alessandro; Barbonaglia, Lorella; Allocca, Giuseppe; Mureddu, Roberto; Marenna, Biondino; Rossi, Paolo; Vaccari, Diego; Chianca, Roberto; Indiani, Stefano; DI Matteo, Irene; Angheben, Carlo; Zorzi, Alessandro

    2017-01-01

    Cardiac resynchronization therapy (CRT) device implantation guided by an electroanatomic mapping system (EAMS) is an emerging technique that may reduce fluoroscopy and angiography use and provide information on coronary sinus (CS) electrical activation. We evaluated the outcome of the EAMS-guided CRT implantation technique in a multicenter registry. During the period 2011-2014 we enrolled 125 patients (80% males, age 74 [71-77] years) who underwent CRT implantation by using the EnSite system to create geometric models of the patient's cardiac chambers, build activation mapping of the CS, and guide leads positioning. Two hundred and fifty patients undergoing traditional CRT implantation served as controls. Success and complication rates, fluoroscopy and total procedure times in the overall study population and according to center experience were collected. Centers that performed ≥10 were defined as highly experienced. Left ventricular lead implantation was successful in 122 (98%) cases and 242 (97%) controls (P = 0.76). Median fluoroscopy time was 4.1 (0.3-10.4) minutes in cases versus 16 (11-26) minutes in controls (P < 0.001). Coronary sinus angiography was performed in 33 (26%) cases and 208 (83%) controls (P < 0.001). Complications occurred in 5 (4%) cases and 17 (7%) controls (P = 0.28). Median fluoroscopy time (median 11 minutes vs. 3 minutes, P < 0.001) and CS angiography rate (55% vs. 21%, P < 0.001) were significantly higher in low experienced centers, while success rate and complications rate were similar. EAMS-guided CRT implantation proved safe and effective in both high- and low-experienced centers and allowed to reduce fluoroscopy use by ≈75% and angiography rate by ≈70%. © 2016 Wiley Periodicals, Inc.

  8. Different encapsulation strategies for implanted electronics

    Directory of Open Access Journals (Sweden)

    Winkler Sebastian

    2017-09-01

    Full Text Available Recent advancements in implant technology include increasing application of electronic systems in the human body. Hermetic encapsulation of electronic components is necessary, specific implant functions and body environments must be considered. Additional functions such as wireless communication systems require specialized technical solutions for the encapsulation.

  9. Nonlinear model of high-dose implantation

    International Nuclear Information System (INIS)

    Danilyuk, A.

    2001-01-01

    The models of high-dose implantation, using the distribution functions, are relatively simple. However, they must take into account the variation of the function of distribution of the implanted ions with increasing dose [1-4]. This variation takes place owing to the fact that the increase of the concentration of the implanted ions results in a change of the properties of the target. High-dose implantation is accompanied by sputtering, volume growth, diffusion, generation of defects, formation of new phases, etc. The variation of the distribution function is determined by many factors and is not known in advance. The variation within the framework of these models [1-4] is taken into account in advance by the introduction of intuitive assumptions on the basis of implicit considerations. Therefore, these attempts should be regarded as incorrect. The model prepared here makes it possible to take into account the sputtering of the target, volume growth and additional declaration on the implanted ions. Without any assumptions in relation to the variation of the distribution function with increasing dose. In our model it is assumed that the type of distribution function for small doses in a pure target substance is the same as in substances with implanted ions. A second assumption relates to the type of the distribution function valid for small doses in the given substances. These functions are determined as a result of a large number of theoretical and experimental investigations and are well-known at the present time. They include the symmetric and nonsymmetric Gauss distribution, the Pearson distribution, and others. We examine implantation with small doses of up to 10 14 - 10 15 cm -2 when the accurately known distribution is valid

  10. Hemiepiphysiodesis Implants for Late-onset Tibia Vara: A Comparison of Cost, Surgical Success, and Implant Failure.

    Science.gov (United States)

    Funk, Shawn S; Mignemi, Megan E; Schoenecker, Jonathan G; Lovejoy, Steven A; Mencio, Gregory A; Martus, Jeffrey E

    2016-01-01

    The purpose of this study was to compare hemiepiphysiodesis implants for late-onset tibia vara and to evaluate patient characteristics that may predict surgical failure. This is a retrospective review of late-onset tibia vara patients treated with temporary hemiepiphysiodesis from 1998 to 2012. Mechanical axis deviation (MAD), mechanical axis angle, mechanical lateral distal femoral angle, and medial proximal tibial angle were measured on standing bone length radiographs. Surgical failure was defined as residual deformity requiring osteotomy, revision surgery, or MAD exceeding 40 mm at the time of final follow-up. Implant failure was recorded. Costs included implants and disposables required for construct placement. Staple constructs included 2 or 3 staples. Plate constructs included the plate, screws, guide wires, and drill bits. A total of 25 patients with 38 temporary lateral proximal tibia hemiepiphysiodeses met the inclusion criteria. The average body mass index (BMI) was 39.1 kg/m with an average follow-up of 3.0 years (minimum 1 y). Surgical failure occurred in 57.9% of patients. Greater BMI (P=0.05) and more severe deformity (MAD, mechanical axis angle, and medial proximal tibial angle; Pfailure. Younger age predicted higher rates of implant failure (Pfailure between staple and plate systems. Hospital costs of plate constructs ($781 to $1244) were 1.5 to 3.5 times greater than the staple constructs ($332 to $498). Greater BMI, more severe deformity, and younger age were predictive of surgical or implant failure. There was no difference in success between implant types, whereas the cost of plate constructs was 1.5 to 3.5 times greater than staples. The rate of surgical failure was high (58%) and consideration should be given to reserving hemiepiphysiodesis for patients with lower BMI and less severe deformity. In our population, if hemiepiphysiodesis was not offered to patients with BMI>35 or MAD>80 mm varus, the surgical failure rate would diminish to 28

  11. Expression of Pattern Recognition Receptors in Epithelial Cells Around Clinically Healthy Implants and Healthy Teeth.

    Science.gov (United States)

    Calcaterra, Roberta; Di Girolamo, Michele; Mirisola, Concetta; Baggi, Luigi

    2016-06-01

    Gingival epithelial cells have a pivotal role in the recognition of microorganisms and damage-associated molecular pattern molecules and in the regulation of the immune response. The investigation of the behavior of Toll-like receptors (TLRs) and nucleotide oligomerization domain (NOD) like receptors (NLRs) around a healthy implant may help to address the first step of periimplantitis pathogenesis. To investigate by quantitative real-time polymerase chain reaction, the mRNA expressions of TLR2, TLR3, TLR4, TLR5, TLR6, TLR9, NOD1, NOD2, and NLRP3 from gingival epithelial cells of the sulcus around healthy implants and around healthy teeth. Two types of implant-abutment systems with tube-in-tube interface were tested. After 6 months of implant restoration, gingival epithelial cells were obtained from the gingival sulcus around the implants and around the adjacent teeth of 10 patients. Our results did not reach statistical significance among the mRNA expressions of TLR2, TLR3, TLR4, TLR5, TLR6, TLR9, NOD1, NOD2, and NLRP3 in epithelial cells around the implant versus around natural teeth. This study shows that the implant-abutment systems tested did not induce an immune response by the surrounding epithelial cells at 6 months since their positioning, as well as in the adjacent clincally healthy teeth.

  12. Systemic levels of metallic ions released from orthodontic mini-implants.

    Science.gov (United States)

    de Morais, Liliane Siqueira; Serra, Glaucio Guimarães; Albuquerque Palermo, Elisabete Fernandes; Andrade, Leonardo Rodrigues; Müller, Carlos Alberto; Meyers, Marc André; Elias, Carlos Nelson

    2009-04-01

    Orthodontic mini-implants are a potential source of metallic ions to the human body because of the corrosion of titanium (Ti) alloy in body fluids. The purpose of this study was to gauge the concentration of Ti, aluminum (Al), and vanadium (V), as a function of time, in the kidneys, livers, and lungs of rabbits that had Ti-6Al-4V alloy orthodontic mini-implants placed in their tibia. Twenty-three New Zealand rabbits were randomly divided into 4 groups: control, 1 week, 4 weeks, and 12 weeks. Four orthodontic mini-implants were placed in the left proximal tibia of 18 rabbits. Five control rabbits had no orthodontic mini-implants. After 1, 4, and 12 weeks, the rabbits were killed, and the selected tissues were extracted and prepared for analysis by graphite furnace atomic absorption spectrophotometry. Low amounts of Ti, Al, and V were detectable in the 1-week, 4-weeks, and 12-weeks groups, confirming that release of these metals from the mini-implants occurs, with diffusion and accumulation in remote organs. Despite the tendency of ion release when using the Ti alloy as orthodontic mini-implants, the amounts of metals detected were significantly below the average intake of these elements through food and drink and did not reach toxic concentrations.

  13. Percutaneous implantation of intra-arterial port system for regional drug infusion: results and complications in 110 cases

    International Nuclear Information System (INIS)

    Won, Je Hwan; Lee, Jong Hyuk; Ko, Kyung Hee; Won, Jong Yoon; Park, Sung Il; Lee, Do Yun; Kang, Byung Chul

    2000-01-01

    To investigate the feasibility and complications of a percutaneously implantable port system for regional drug infusion. For intra-arterial drug infusion, a 5.8 or 5-F pediatric venous port system was implanted in 110 patients with hepatocellular carcinoma (n=79), liver metastasis (n=16), gallbladder cancer (n=4), stomach cancer (n=3), pancreatic cancer (n=3), Burger's diseases mellitus (n=2), or lymphoma (n=1). All intra-arterial port implantations were performed percutaneously in an angiographic ward through the common femoral artery (n=98), left subclavian artery (n=10), or left superficial femoral artery (n=2). Complications were evaluated during the follow-up period, which ranged from 21 to 530 (mean, 163) days. The technical success rate for percutaneous implantation of the system was 97.3% (107 of 110 patients). The tips of the port catheter were located in the common hepatic artery (n=34), proper hepatic artery (n=49), right hepatic artery quick resulthepatic artery (n=1), descending aorta at T9 level (n=10), left popliteal artery (n=2), right external iliac artery (n=1), left external iliac artery (n=1), or left deep femoral artery (n=1). Complications were encountered in 24 patients (22.4%), namely chamber site infection (n=7), catheter dislodgement (n=7), catheter occlusion (n=3), migration of coil (n=2), disconnection between chamber and catheter (n=1), kinking of catheter (n=1), arterial occlusion (n=1), necrosis of overlying skin (n=1), and leakage around port chamber (n=1). Outcomes of complications included removal of port systems or cessation of therapy in 12 cases (11.2%), correction of catheter location using a guide wire in five (4.7%), thrombolysis with urokinase in three (2.8%), and straightening using a snare in one (0.9%). In three patients, the port system was used without reintervention. Percutaneous implantation of an intra-arterial port system showed a high technical success rate and a low rate of serious complications. The method may be

  14. Therapies targeting inflammation after stent implantation.

    Science.gov (United States)

    Okura, Hiroyuki; Takagi, Tsutomu; Yoshida, Kiyoshi

    2013-07-01

    Since the introduction of coronary vessel scaffold by metallic stent, percutaneous coronary intervention has become widely performed all over the world. Although drug-eluting stent technology has further decrease the incidence of in-stent restenosis, there still remaining issues related to stent implantation. Vessel inflammation is one of the causes that may be related to stent restenosis as well as stent thrombosis. Therefore, systemic therapies targeting inflammation emerged as adjunctive pharmacological intervention to improve outcome. Statins, corticosteroids, antiplatelets, and immunosuppresive or anti-cancer drugs are reported to favorably impact outcome after bare-metal stent implantation. In type 2 diabetic patients, pioglitazone may be the most promising drug that can lower neointimal proliferation and, as a result, lower incidence of restenosis and target lesion revascularization. On the other hand, several new stent platforms that might decrease inflammatory response after drug-eluting stent implantation have been introduced. Because durable polymer used in the first generation drug-eluting stents are recognized to be responsible for unfavorable vessel response, biocompatible or bioabsorbable polymer has been introduce and already used clinically. Furthermore, polymer-free drug-eluting stent and bioresorbable scaffold are under investigation. Although vessel inflammation may be reduced by using these new drug-eluting stents or scaffold, long-term impact needs to be investigated further.

  15. Laboratory implantation for well type ionization chambers calibration; Implantacao de um laboratorio para calibracao de camaras de ionizacao tipo poco

    Energy Technology Data Exchange (ETDEWEB)

    Vianello, E.A.; Dias, D.J.; Almeida, C.E. de [Laboratorio de Ciencias Radiologicas- LCR- DBB (UERJ). R. Sao Francisco Xavier, 524- Pav. HLC, sala 136 terreo- CEP 20.550-013. Rio de Janeiro (Brazil)

    1998-12-31

    The Radiological Science Laboratory is implanting a service for calibration of well type chambers by IAEA training program. The kerma rate in the air (mu Gy/h) of the linear Cs-137 reference source CDCS-J4 have been determined using a well type chamber Standard Imaging HDR-1000 model, which have been calibrated at Secondary Standard Laboratory Calibration of IAEA, whereas two HDR-1000 Plus chambers were calibrated too, following the same standards. The results were compared with Wisconsin University calibration certification and has demonstrated that well type ionization chamber calibration can be used in brachytherapy for several kinds of radionuclides. (Author)

  16. Neuroengineering tools/applications for bidirectional interfaces, brain computer interfaces, and neuroprosthetic implants - a review of recent progress

    Directory of Open Access Journals (Sweden)

    Ryan M Rothschild

    2010-10-01

    Full Text Available The main focus of this review is to provide a holistic amalgamated overview of the most recent human in vivo techniques for implementing brain-computer interfaces (BCIs, bidirectional interfaces and neuroprosthetics. Neuroengineering is providing new methods for tackling current difficulties; however neuroprosthetics have been studied for decades. Recent progresses are permitting the design of better systems with higher accuracies, repeatability and system robustness. Bidirectional interfaces integrate recording and the relaying of information from and to the brain for the development of BCIs. The concepts of non-invasive and invasive recording of brain activity are introduced. This includes classical and innovative techniques like electroencephalography (EEG and near-infrared spectroscopy (NIRS. Then the problem of gliosis and solutions for (semi- permanent implant biocompatibility such as innovative implant coatings, materials and shapes are discussed. Implant power and the transmission of their data through implanted pulse generators (IPGs and wireless telemetry are taken into account. How sensation can be relayed back to the brain to increase integration of the neuroengineered systems with the body by methods such as micro-stimulation and transcranial magnetic stimulation (TMS are then addressed. The neuroprosthetic section discusses some of the various types and how they operate. Visual prosthetics are discussed and the three types, dependant on implant location, are examined. Auditory prosthetics, being cochlear or cortical, are then addressed. Replacement hand and limb prosthetics are then considered. These are followed by sections concentrating on the control of wheelchairs, computers and robotics directly from brain activity as recorded by non-invasive and invasive techniques.

  17. Radiographic implications of procedures involving cardiac implantable electronic devices (CIEDs – Selected aspects

    Directory of Open Access Journals (Sweden)

    Roman Steckiewicz

    2017-06-01

    Full Text Available Background: Some cardiac implantable electronic device (CIED implantation procedures require the use of X-rays, which is reflected by such parameters as total fluoroscopy time (TFT and dose-area product (DAP – defined as the absorbed dose multiplied by the area irradiated. Material and Methods: This retrospective study evaluated 522 CIED implantation (424 de novo and 98 device upgrade and new lead placement procedures in 176 women and 346 men (mean age 75±11 years over the period 2012–2015. The recorded procedure-related parameters TFT and DAP were evaluated in the subgroups specified below. The group of 424 de novo procedures included 203 pacemaker (PM and 171 implantable cardioverter-defibrillator (ICD implantation procedures, separately stratified by single-chamber and dual-chamber systems. Another subgroup of de novo procedures involved 50 cardiac resynchronization therapy (CRT devices. The evaluated parameters in the group of 98 upgrade procedures were compared between 2 subgroups: CRT only and combined PM and ICD implantation procedures. Results: We observed differences in TFT and DAP values between procedure types, with PM-related procedures showing the lowest, ICD – intermediate (with values for single-chamber considerably lower than those for dual-chamber systems and CRT implantation procedures – highest X-ray exposure. Upgrades to CRT were associated with 4 times higher TFT and DAP values in comparison to those during other upgrade procedures. Cardiac resynchronization therapy de novo implantation procedures and upgrades to CRT showed similar mean values of these evaluated parameters. Conclusions: Total fluoroscopy time and DAP values correlated progressively with CIED implantation procedure complexity, with CRT-related procedures showing the highest values of both parameters. Med Pr 2017;68(3:363–374

  18. Cell-laden hydrogel/titanium microhybrids: Site-specific cell delivery to metallic implants for improved integration.

    Science.gov (United States)

    Koenig, Geraldine; Ozcelik, Hayriye; Haesler, Lisa; Cihova, Martina; Ciftci, Sait; Dupret-Bories, Agnes; Debry, Christian; Stelzle, Martin; Lavalle, Philippe; Vrana, Nihal Engin

    2016-03-01

    Porous titanium implants are widely used in dental, orthopaedic and otorhinolaryngology fields to improve implant integration to host tissue. A possible step further to improve the integration with the host is the incorporation of autologous cells in porous titanium structures via cell-laden hydrogels. Fast gelling hydrogels have advantageous properties for in situ applications such as localisation of specific cells and growth factors at a target area without dispersion. The ability to control the cell types in different regions of an implant is important in applications where the target tissue (i) has structural heterogeneity (multiple cell types with a defined spatial configuration with respect to each other); (ii) has physical property gradients essential for its function (such as in the case of osteochondral tissue transition). Due to their near immediate gelation, such gels can also be used for site-specific modification of porous titanium structures, particularly for implants which would face different tissues at different locations. Herein, we describe a step by step design of a model system: the model cell-laden gel-containing porous titanium implants in the form of titanium microbead/hydrogel (maleimide-dextran or maleimide-PVA based) microhybrids. These systems enable the determination of the effect of titanium presence on gel properties and encapsulated cell behaviour as a miniaturized version of full-scale implants, providing a system compatible with conventional analysis methods. We used a fibroblast/vascular endothelial cell co-cultures as our model system and by utilising single microbeads we have quantified the effect of gel microenvironment (degradability, presence of RGD peptides within gel formulation) on cell behaviour and the effect of the titanium presence on cell behaviour and gel formation. Titanium presence slightly changed gel properties without hindering gel formation or affecting cell viability. Cells showed a preference to move towards

  19. A touch probe method of operating an implantable RFID tag for orthopedic implant identification.

    Science.gov (United States)

    Liu, Xiaoyu; Berger, J Lee; Ogirala, Ajay; Mickle, Marlin H

    2013-06-01

    The major problem in operating an implantable radio-frequency identification (RFID) tag embedded on an orthopedic implant is low efficiency because of metallic interference. To improve the efficiency, this paper proposes a method of operating an implantable passive RFID tag using a touch probe at 13.56 MHz. This technology relies on the electric field interaction between two pairs of electrodes, one being a part of the touch probe placed on the surface of tissue and the other being a part of the tag installed under the tissue. Compared with using a conventional RFID antenna such as a loop antenna, this method has a better performance in the near field operation range to reduce interference with the orthopedic implant. Properly matching the touch probe and the tag to the tissue and the implant reduces signal attenuation and increases the overall system efficiency. The experiments have shown that this method has a great performance in the near field transcutaneous operation and can be used for orthopedic implant identification.

  20. Prosthodontic maintenance of overdentures on zirconia implants: 1-year results of a randomized controlled trial.

    Science.gov (United States)

    Osman, Reham B; Ma, Sunyoung

    2014-01-01

    The purpose of this study was to determine the prosthodontic outcomes of one-piece zirconia implants and their attachment systems in edentulous participants with maxillary and mandibular overdentures after 1 year of a randomized controlled trial. Random allocation of 24 edentulous participants (age range: 45 to 86 years) into titanium (control) or zirconia (test) groups using onepiece implants and a planned unsplinted prosthodontic design was performed. Four maxillary implants (one midpalatal; three anterior crestal) and three mandibular implants (one midsymphyseal; two bilateral distal) were conventionally loaded with the overdentures. Similar attachment systems were used throughout: ball abutment-type patrices (diameter: 2.25 to 3.1 mm as part of the one-piece implants) and custommade plastic matrices (with or without metal housings depending on the patrix size). Prosthodontic outcomes were documented during the first year of the clinical trial. Following three deaths and two dropouts, there were 19 participants who were available at the 1-year recall. Of these participants, 3 had early maxillary implant failure and had to be converted to conventional maxillary complete dentures opposing mandibular implant overdentures. There were 79 maintenance events, 34 in the titanium (control) group and 45 in the zirconia (test) group. Patrix loss occurred as a result of three zirconia implant fractures (one mandibular and two crestal maxillary implants). Maintenance events were principally the replacement of matrices and overdenture fracture. Although relines and replacement overdentures also occurred, overall there were no significant differences in prosthodontic maintenance between the control and test groups. A six-field prosthodontic-success analysis table showed no statistically significant difference between the two groups; however, 50% of participants in each group were allocated to the retreatment (repair) field, which produced a low prosthodontic success rate

  1. Transverse microanalysis of high energy Ion implants

    Energy Technology Data Exchange (ETDEWEB)

    Dooley, S.P.; Jamieson, D.N.; Nugent, K.W.; Prawer, S. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    High energy ion implants in semiconductor materials have been analyzed by Channeling Contrast Microscopy (CCM) perpendicular to the implant direction, allowing imaging of the entire ion track. The damage produced by Channeled and Random 1.4 MeV H{sup +} implants into the edge of a <100> type IIa diamond wafer were analyzed by channeling into the face of the crystal. The results showed negligible damage in the surface region of the implants, and swelling induced misalignment at the end of range of the implants. Channeled 1.4 MeV H{sup +} implants in diamond had a range only 9% deeper than Random implants, which could be accounted for by dechanneling of the beam. The channeling of H{sup +}{sub 2} ions has been previously found to be identical to that of protons of half energy, however the current experiment has shown a 1% increase in {chi}{sub min} for H{sup +}{sub 2} in diamond compared to H{sup +} at 1,2 MeV per proton. This is due to repulsion between protons within the same channel. 5 refs., 2 figs.

  2. Transverse microanalysis of high energy Ion implants

    Energy Technology Data Exchange (ETDEWEB)

    Dooley, S P; Jamieson, D N; Nugent, K W; Prawer, S [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    High energy ion implants in semiconductor materials have been analyzed by Channeling Contrast Microscopy (CCM) perpendicular to the implant direction, allowing imaging of the entire ion track. The damage produced by Channeled and Random 1.4 MeV H{sup +} implants into the edge of a <100> type IIa diamond wafer were analyzed by channeling into the face of the crystal. The results showed negligible damage in the surface region of the implants, and swelling induced misalignment at the end of range of the implants. Channeled 1.4 MeV H{sup +} implants in diamond had a range only 9% deeper than Random implants, which could be accounted for by dechanneling of the beam. The channeling of H{sup +}{sub 2} ions has been previously found to be identical to that of protons of half energy, however the current experiment has shown a 1% increase in {chi}{sub min} for H{sup +}{sub 2} in diamond compared to H{sup +} at 1,2 MeV per proton. This is due to repulsion between protons within the same channel. 5 refs., 2 figs.

  3. Design and optimization of a 3-coil resonance-based wireless power transfer system for biomedical implants

    KAUST Repository

    Yi, Ying

    2014-09-01

    This paper presents a resonance-based wireless power transfer system using a single layer of inductor coil windings, in a pancake configuration, in order to obtain a compact system for implantable electronic applications. We theoretically analyzed the system and characterized it by measuring its inductance, self-resonant frequency, and quality factor Q. In our resonance-based wireless power transfer prototype, we proposed a 3-coil system, using two 15-mm radius implantable coils, with a resonance frequency of 6.76MHz. This system can effectively transfer power for a distance of up to 50mm. Moreover, our proposed 3-coil system can achieve a high Q-factor and has a comparable power transfer efficiency (PTE) to previously reported works about 3-coil and 4-coil systems. The experimental PTE can achieve 82.4% at a separation distance of 20mm and more than 10% PTE at a distance of 40mm.

  4. Design and optimization of a 3-coil resonance-based wireless power transfer system for biomedical implants

    KAUST Repository

    Yi, Ying; Buttner, Ulrich; Fan, Yiqiang; Foulds, Ian G.

    2014-01-01

    This paper presents a resonance-based wireless power transfer system using a single layer of inductor coil windings, in a pancake configuration, in order to obtain a compact system for implantable electronic applications. We theoretically analyzed the system and characterized it by measuring its inductance, self-resonant frequency, and quality factor Q. In our resonance-based wireless power transfer prototype, we proposed a 3-coil system, using two 15-mm radius implantable coils, with a resonance frequency of 6.76MHz. This system can effectively transfer power for a distance of up to 50mm. Moreover, our proposed 3-coil system can achieve a high Q-factor and has a comparable power transfer efficiency (PTE) to previously reported works about 3-coil and 4-coil systems. The experimental PTE can achieve 82.4% at a separation distance of 20mm and more than 10% PTE at a distance of 40mm.

  5. [Application of endosseous screw implants. Indications and planning].

    Science.gov (United States)

    Pajarola, G F; Sailer, H F

    1991-01-01

    To achieve long term positive results for endosseous dental implants, three points have to be considered: the osséointegration, the correct indication and the suprastructural planification designed for the spécific type of implant. If the surgery part is done by a different practitioner as the prosthetic part, tight coworking for planning is necessary and the responsibility in each step has to be cleared in advance. The planification in implant cases is divided into three stages: clearing of contraindications, choice of the suprastructure, and the surgery planning. Aids for exact localisation of the implants are presented.

  6. Automated dental implantation using image-guided robotics: registration results.

    Science.gov (United States)

    Sun, Xiaoyan; McKenzie, Frederic D; Bawab, Sebastian; Li, Jiang; Yoon, Yongki; Huang, Jen-K

    2011-09-01

    One of the most important factors affecting the outcome of dental implantation is the accurate insertion of the implant into the patient's jaw bone, which requires a high degree of anatomical accuracy. With the accuracy and stability of robots, image-guided robotics is expected to provide more reliable and successful outcomes for dental implantation. Here, we proposed the use of a robot for drilling the implant site in preparation for the insertion of the implant. An image-guided robotic system for automated dental implantation is described in this paper. Patient-specific 3D models are reconstructed from preoperative Cone-beam CT images, and implantation planning is performed with these virtual models. A two-step registration procedure is applied to transform the preoperative plan of the implant insertion into intra-operative operations of the robot with the help of a Coordinate Measurement Machine (CMM). Experiments are carried out with a phantom that is generated from the patient-specific 3D model. Fiducial Registration Error (FRE) and Target Registration Error (TRE) values are calculated to evaluate the accuracy of the registration procedure. FRE values are less than 0.30 mm. Final TRE values after the two-step registration are 1.42 ± 0.70 mm (N = 5). The registration results of an automated dental implantation system using image-guided robotics are reported in this paper. Phantom experiments show that the practice of robot in the dental implantation is feasible and the system accuracy is comparable to other similar systems for dental implantation.

  7. Spectral-Temporal Modulated Ripple Discrimination by Children With Cochlear Implants.

    Science.gov (United States)

    Landsberger, David M; Padilla, Monica; Martinez, Amy S; Eisenberg, Laurie S

    A postlingually implanted adult typically develops hearing with an intact auditory system, followed by periods of deafness (or near deafness) and adaptation to the implant. For an early implanted child whose brain is highly plastic, the auditory system matures with consistent input from a cochlear implant. It is likely that the auditory system of early implanted cochlear implant users is fundamentally different than postlingually implanted adults. The purpose of this study is to compare the basic psychophysical capabilities and limitations of these two populations on a spectral resolution task to determine potential effects of early deprivation and plasticity. Performance on a spectral resolution task (Spectral-temporally Modulated Ripple Test [SMRT]) was measured for 20 bilaterally implanted, prelingually deafened children (between 5 and 13 years of age) and 20 hearing children within the same age range. Additionally, 15 bilaterally implanted, postlingually deafened adults, and 10 hearing adults were tested on the same task. Cochlear implant users (adults and children) were tested bilaterally, and with each ear alone. Hearing listeners (adults and children) were tested with the unprocessed SMRT and with a vocoded version that simulates an 8-channel cochlear implant. For children with normal hearing, a positive correlation was found between age and SMRT score for both the unprocessed and vocoded versions. Older hearing children performed similarly to hearing adults in both the unprocessed and vocoded test conditions. However, for children with cochlear implants, no significant relationship was found between SMRT score and chronological age, age at implantation, or years of implant experience. Performance by children with cochlear implants was poorer than performance by cochlear implanted adults. It was also found that children implanted sequentially tended to have better scores with the first implant compared with the second implant. This difference was not

  8. Maxillary Three-Implant Overdentures Opposing Mandibular Two-Implant Overdentures: 10-Year Surgical Outcomes of a Randomized Controlled Trial.

    Science.gov (United States)

    Ma, Sunyoung; Tawse-Smith, Andrew; De Silva, Rohana K; Atieh, Momen A; Alsabeeha, Nabeel H M; Payne, Alan G T

    2016-06-01

    The surgical placement of four maxillary implants for overdentures may not be obligatory when opposing mandibular two-implant overdentures. To determine 10-year surgical outcomes and implant success of three narrow diameter implants in edentulous maxillae with conventional loading. Forty participants with mandibular two-implant overdentures were randomly allocated for surgery for maxillary overdentures. Using osteotomes, three implants of similar systems were placed with a one-stage procedure and 12-week loading with splinted and unsplinted prosthodontic designs. Marginal bone and stability measurements were done at surgery, 12 weeks, 1-, 2-, 5-, 7-, 10 years. One hundred seventeen implants were placed in 39 participants, with 35 being seen at 1 year; 29 at 2 years; 28 at 5 years; 26 at 7 years; and 23 (59%) at 10 years. Marginal bone loss was 1.35 mm between surgery and 12 weeks; 0.36 mm between 12 weeks and 1 year; 0.48 mm between 1 and 5 years; and 0.22 mm between 5 and 10 years. Implant stability quotients were 56.05, 57.54, 60.88, 58.80, 61.17 at surgery, 12 weeks, 1 year, 5 years, and 10 years. Four-field tables by implant showed success rates of 82% at 1 year; 69.2% at 2 years; 66.7% at 5 years; 61.5% at 7 years; 51.3% at 10 years. Data showed no differences between surgical technique, systems, or prosthodontic designs. Surgical placement with osteotomes of three narrow diameter implants for maxillary overdentures, opposing mandibular two-implant overdentures, is an acceptable approach, subject to strict patient selection. Implant success is independent of prosthodontic design. © 2015 Wiley Periodicals, Inc.

  9. The effects of handling and storage on magnesium based implants — First results

    Energy Technology Data Exchange (ETDEWEB)

    Ullmann, Berit, E-mail: berit.ullmann@tiho-hannover.de [University of Veterinary Medicine, Small Animal Clinic, Bünteweg 9, 30559 Hannover (Germany); Angrisani, Nina, E-mail: nina.angrisani@tiho-hannover.de [University of Veterinary Medicine, Small Animal Clinic, Bünteweg 9, 30559 Hannover (Germany); Reifenrath, Janin, E-mail: janin.reifenrath@tiho-hannover.de [University of Veterinary Medicine, Small Animal Clinic, Bünteweg 9, 30559 Hannover (Germany); Seitz, Jan-M., E-mail: seitz@iw.uni-hannover.de [Leibniz University, Institute of Materials Science, An der Universität 2, 30823 Hannover (Germany); Bormann, Dirk, E-mail: dirk.bormann@trimet.de [Leibniz University, Institute of Materials Science, An der Universität 2, 30823 Hannover (Germany); Trimet Aluminium AG, Automotive, Recycling Harzgerode, Aluminiumallee 1, 06493 Harzgerode (Germany); Bach, Friedrich-Wilhelm, E-mail: bach@iw.uni-hannover.de [Leibniz University, Institute of Materials Science, An der Universität 2, 30823 Hannover (Germany); Meyer-Lindenberg, Andrea, E-mail: meyer-lindenberg@chir.vetmed.uni-muenchen.de [University of Veterinary Medicine, Small Animal Clinic, Bünteweg 9, 30559 Hannover (Germany); Clinic for Small Animal Surgery and Reproduction, Centre of Clinical Veterinary Medicine, Faculty of Veterinary Medicine, Ludwig-Maximilians-Universität München, Veterinärstraße 3, 80539 München (Germany)

    2013-07-01

    The present work aimed to investigate the influence of acetone and formalin as well as the duration and type of storage on magnesium based implants by means of microscopic, μ-computed tomographic, scanning electron microscopic, EDX and metallographic investigations. In contrast to storing in acetone, storage in formalin led to an increase in surface to volume ratio, and a decrease of the volume and the density. The various types of storage exerted no differing effects on the implants but with increasing storage duration, a spreading of oxygen rich areas on the surface, increased precipitations and a decrease in grain size could be observed. - Highlights: • Acetone treatment had no detectable effect on magnesium based implants. • Formalin caused distinct changes of the implant's surface, volume and density. • Storage types had no differing effect on the implants. • Storage duration led to distinct changes of the implant's surface and structure.

  10. Reliable and energy-efficient communications for wireless biomedical implant systems.

    Science.gov (United States)

    Ntouni, Georgia D; Lioumpas, Athanasios S; Nikita, Konstantina S

    2014-11-01

    Implant devices are used to measure biological parameters and transmit their results to remote off-body devices. As implants are characterized by strict requirements on size, reliability, and power consumption, applying the concept of cooperative communications to wireless body area networks offers several benefits. In this paper, we aim to minimize the power consumption of the implant device by utilizing on-body wearable devices, while providing the necessary reliability in terms of outage probability and bit error rate. Taking into account realistic power considerations and wireless propagation environments based on the IEEE P802.l5 channel model, an exact theoretical analysis is conducted for evaluating several communication scenarios with respect to the position of the wearable device and the motion of the human body. The derived closed-form expressions are employed toward minimizing the required transmission power, subject to a minimum quality-of-service requirement. In this way, the complexity and power consumption are transferred from the implant device to the on-body relay, which is an efficient approach since they can be easily replaced, in contrast to the in-body implants.

  11. Object-Oriented Type Systems

    DEFF Research Database (Denmark)

    Schwartzbach, Michael Ignatieff; Palsberg, Jens

    binding. Existing languages employ different type systems, and it can be difficult to compare, evaluate and improve them, since there is currently no uniform theory for such languages. This book provides such a theory. The authors review the type systems of Simula, Smalltalk, C++ and Eiffel and present......Object-Oriented Type Systems Jens Palsberg and Michael I. Schwartzbach Aarhus University, Denmark Type systems are required to ensure reliability and efficiency of software. For object-oriented languages, typing is an especially challenging problem because of inheritance, assignment, and late...... a type system that generalizes and explains them. The theory is based on an idealized object-oriented language called BOPL (Basic Object Programming Language), containing common features of the above languages. A type system, type inference algorithm, and typings of inheritance and genericity...

  12. Prosthetic management of malpositioned implant using custom cast abutment

    Science.gov (United States)

    Chatterjee, Aishwarya; Ragher, Mallikarjuna; Patil, Sanket; Chatterjee, Debopriya; Dandekeri, Savita; Prabhu, Vishnu

    2015-01-01

    Two cases are reported with malpositioned implants. Both the implants were placed 6–7 months back. They had osseointegrated well with the surrounding bone. However, they presented severe facial inclination. Case I was restored with custom cast abutment with an auto polymerizing acrylic gingival veneer. Case II was restored with custom cast UCLA type plastic implant abutment. Ceramic was directly fired on the custom cast abutments. The dual treatment strategy resulted in functional and esthetic restorations despite facial malposition of the implants. PMID:26538957

  13. Ion implantation of boron in germanium

    International Nuclear Information System (INIS)

    Jones, K.S.

    1985-05-01

    Ion implantation of 11 B + into room temperature Ge samples leads to a p-type layer prior to any post implant annealing steps. Variable temperature Hall measurements and deep level transient spectroscopy experiments indicate that room temperature implantation of 11 B + into Ge results in 100% of the boron ions being electrically active as shallow acceptor, over the entire dose range (5 x 10 11 /cm 2 to 1 x 10 14 /cm 2 ) and energy range (25 keV to 100 keV) investigated, without any post implant annealing. The concentration of damage related acceptor centers is only 10% of the boron related, shallow acceptor center concentration for low energy implants (25 keV), but becomes dominant at high energies (100 keV) and low doses ( 12 /cm 2 ). Three damage related hole traps are produced by ion implantation of 11 B + . Two of these hole traps have also been observed in γ-irradiated Ge and may be oxygen-vacancy related defects, while the third trap may be divacancy related. All three traps anneal out at low temperatures ( 0 C). Boron, from room temperature implantation of BF 2 + into Ge, is not substitutionally active prior to a post implant annealing step of 250 0 C for 30 minutes. After annealing additional shallow acceptors are observed in BF 2 + implanted samples which may be due to fluorine or flourine related complexes which are electrically active

  14. Impact of systemic diseases on oral health related quality of life after implant-prosthodontic rehabilitation

    Directory of Open Access Journals (Sweden)

    Tina Pretnar

    2014-08-01

    Full Text Available Background: Implant-prosthodontic rehabilitation improves oral health related quality of life (OHRQoL, but the presence of systemic diseases can also affect the well-being of an individual.The study was carried out to determine the relationship between systemic diseases and OHRQoL after implant-prosthodontic rehabilitation on the basis of psychometric testing by a standardized questionnaire »Oral Health Impact Profile« (OHIP.Methods: 130 patients, who received one to eight Ankylos® implants (on average 2.6 ± 1.8 were included in this retrospective study in which all aspects of the OHRQoL construct were evaluated with a Slovenian version of the OHIP questionnaire. Data on all present systemic diseases were obtained from the existing health records. Dental status and dental restorations were identified on the basis of orthopantomographic images.Results: The majority of subjects had a cardiovascular disease (N = 37; 28.5 %, followed by a headache (N = 15, 11.5 %, allergies and asthma (n = 13, 10 %, and a rheumatic disease (N = 11, 8.5 %. Only osteoporosis was statistically significantly related to OHRQoL after implant-prosthodontic rehabilitation (p = 0.024. The best multiple linear regression model for the summary score for the questionnaire »Oral Health Impact Profile« for Slovenia (OHIP, and taking into account gender and age as confounding factors, included the number of remaining teeth and the presence of osteoporosis (p = 0.003, adjusted R2 = 0.104.Conclusions: The total number of remaining teeth in the oral cavity (p = 0.031, the presence of osteoporosis (p = 0.024, and taking into account the subject’s gender and age, are the most important clinical factors that affect the functioning of the SGS as well as psychosocial behavior of the patients after an implant-prosthodontic rehabilitation (adjusted R2 = 0.104. Other systemic diseases (cardiovascular disease, headache, allergies and

  15. Three-Dimensional Finite Element Analysis of the Stress Distribution at the Internal Implant-Abutment Connection.

    Science.gov (United States)

    Cho, Sung-Yong; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    2016-01-01

    This study investigated stress distribution in four different implant-abutment interface conditions in the internal tapered connection implant system. Four different implant diameters (3.5 mm, 4.0 mm, 4.5 mm, and 5.0 mm) and two abutment types (hexagonal and conical) were simulated. Four unique implant-abutment interface conditions were assumed based on wall thickness, mating surface length, distance to the vertical stop, and abutment shape. Axial and oblique loading was applied during abutment screw preload, and the Von Mises stresses were measured at the implant-abutment and abutment-screw interfaces. The implant-abutment interface stress decreased as the wall thickness increased. As the mating surface increased, the stress distribution trended downward, and when the distance to the implant vertical stop was 0 μm, the Von Mises stress was extremely high at the vertical stop. Despite their different shapes, the abutments showed similar stress distributions. However, the maximum Von Mises stress was higher in the conical connection than in the hexagonal connection, particularly at the contralateral side to loading. To decrease the stress distribution at the implant-abutment interface, the implant wall thickness, mating surface contact length, distance to the vertical stop, and abutment shape should be carefully considered.

  16. Cochlear implant revision surgeries in children.

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  17. Determining Threshold Distance Providing Less Interference for Wireless Medical Implant Communication Systems in Coexisting Environments under Shadow Fading Conditions

    Directory of Open Access Journals (Sweden)

    Selman KULAÇ

    2017-08-01

    Full Text Available Important interference problems will be able to be encountered especially close areas to the hospitals where wireless implantable medical systems' communication traffic occurs heavily in near future. It is possible that these interferences could cause wireless implant devices to malfunction and harmful effects on patients. In this study, it is proposed to determine threshold distance in order to get less interference for wireless implantable medical systems under shadow fading conditions where MICS band and MetAids band users coexist intensely simultaneously. In this method, threshold power according to the \\cite{FCC} is pulled down by adding extra distance margin in order to minimize the interference effects to the MICS systems using confidence interval calculations. Because received signal strength just below the monitoring threshold power according to the \\cite{FCC} brings about much more interferences for the MICS systems even if listen-before-talk technique is applied.

  18. Audiovisual segregation in cochlear implant users.

    Directory of Open Access Journals (Sweden)

    Simon Landry

    Full Text Available It has traditionally been assumed that cochlear implant users de facto perform atypically in audiovisual tasks. However, a recent study that combined an auditory task with visual distractors suggests that only those cochlear implant users that are not proficient at recognizing speech sounds might show abnormal audiovisual interactions. The present study aims at reinforcing this notion by investigating the audiovisual segregation abilities of cochlear implant users in a visual task with auditory distractors. Speechreading was assessed in two groups of cochlear implant users (proficient and non-proficient at sound recognition, as well as in normal controls. A visual speech recognition task (i.e. speechreading was administered either in silence or in combination with three types of auditory distractors: i noise ii reverse speech sound and iii non-altered speech sound. Cochlear implant users proficient at speech recognition performed like normal controls in all conditions, whereas non-proficient users showed significantly different audiovisual segregation patterns in both speech conditions. These results confirm that normal-like audiovisual segregation is possible in highly skilled cochlear implant users and, consequently, that proficient and non-proficient CI users cannot be lumped into a single group. This important feature must be taken into account in further studies of audiovisual interactions in cochlear implant users.

  19. Current use of implantable electrical devices in Sweden: data from the Swedish pacemaker and implantable cardioverter-defibrillator registry.

    Science.gov (United States)

    Gadler, Fredrik; Valzania, Cinzia; Linde, Cecilia

    2015-01-01

    The National Swedish Pacemaker and Implantable Cardioverter-Defibrillator (ICD) Registry collects prospective data on all pacemaker and ICD implants in Sweden. We aimed to report the 2012 findings of the Registry concerning electrical devices implantation rates and changes over time, 1 year complications, long-term device longevity and patient survival. Forty-four Swedish implanting centres continuously contribute implantation of pacemakers and ICDs to the Registry by direct data entry on a specific website. Clinical and technical information on 2012 first implants and postoperative complications were analysed and compared with previous years. Patient survival data were obtained from the Swedish population register database. In 2012, the mean pacemaker and ICD first implantation rates were 697 and 136 per million inhabitants, respectively. The number of cardiac resynchronization therapy (CRT) first implantations/million capita was 41 (CRT pacemakers) and 55 (CRT defibrillators), with only a slight increase in CRT-ICD rate compared with 2011. Most device implantations were performed in men. Complication rates for pacemaker and ICD procedures were 5.3 and 10.1% at 1 year, respectively. Device and lead longevity differed among manufacturers. Pacemaker patients were older at the time of first implant and had generally worse survival rate than ICD patients (63 vs. 82% after 5 years). Pacemaker and ICD implantation rates seem to have reached a level phase in Sweden. Implantable cardioverter-defibrillator and CRT implantation rates are very low and do not reflect guideline indications. Gender differences in CRT and ICD implantations are pronounced. Device and patient survival rates are variable, and should be considered when deciding device type. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  20. Evaluation of stress patterns produced by implant-retained overdentures and implant-retained fixed partial denture.

    Science.gov (United States)

    Mazaro, José Vitor Quinelli; Filho, Humberto Gennari; Vedovatto, Eduardo; Pellizzer, Eduardo Piza; Rezende, Maria Cristina Rosifini Alves; Zavanelli, Adriana Cristina

    2011-11-01

    The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 × 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

  1. Load Transfer Characteristics of Various Designs of Three-Implant-Retained Mandibular Overdentures.

    Science.gov (United States)

    Tokar, Emre; Uludag, Bulent

    2015-01-01

    Many different attachment systems (eg, bars, studs, magnets, telescopic copings) have been used to retain overdentures. The current study aimed to investigate the load transfer characteristics and to compare the stress levels of four attachment designs for mandibular overdentures retained by one central implant and two inclined distal implants. Photoelastic mandibular models fabricated with three screw-type implants (Tapered Screw-Vent, 3.75 × 13 mm) were placed in the parasymphyseal area. The center implant was vertically oriented to the midline, and the other implants were embedded in the canine areas with a 20-degree angulation relative to the center implant. Four overdentures with different attachment designs (bar, bar/ball, bar/distally placed Rk-1s, and Locators) were studied in the context of this model. Vertical loads (100 N) were applied to the central fossa of the right first molar area of each overdenture. Stress levels that developed in the denture-bearing areas and around the implants were observed photoelastically and evaluated visually. The studied attachment designs showed low and moderate stress levels. The greatest stress was found with the bar/ball design, while the lowest stress levels were observed with the Locator attachment design. Stresses were concentrated on the loaded side for each design. All tested designs experienced moderate stress around the posterior edentulous area. None of the designs experienced more than moderate stress. The lowest stress was noted with the Locator attachments, which transmitted little discernible stress around the implants.

  2. Cochlear implant rehabilitation outcomes in Waardenburg syndrome children.

    Science.gov (United States)

    de Sousa Andrade, Susana Margarida; Monteiro, Ana Rita Tomé; Martins, Jorge Humberto Ferreira; Alves, Marisa Costa; Santos Silva, Luis Filipe; Quadros, Jorge Manuel Cardoso; Ribeiro, Carlos Alberto Reis

    2012-09-01

    The purpose of this study was to review the outcomes of children with documented Waardenburg syndrome implanted in the ENT Department of Centro Hospitalar de Coimbra, concerning postoperative speech perception and production, in comparison to the rest of non-syndromic implanted children. A retrospective chart review was performed for children congenitally deaf who had undergone cochlear implantation with multichannel implants, diagnosed as having Waardenburg syndrome, between 1992 and 2011. Postoperative performance outcomes were assessed and confronted with results obtained by children with non-syndromic congenital deafness also implanted in our department. Open-set auditory perception skills were evaluated by using European Portuguese speech discrimination tests (vowels test, monosyllabic word test, number word test and words in sentence test). Meaningful auditory integration scales (MAIS) and categories of auditory performance (CAP) were also measured. Speech production was further assessed and included results on meaningful use of speech Scale (MUSS) and speech intelligibility rating (SIR). To date, 6 implanted children were clinically identified as having WS type I, and one met the diagnosis of type II. All WS children received multichannel cochlear implants, with a mean age at implantation of 30.6±9.7months (ranging from 19 to 42months). Postoperative outcomes in WS children were similar to other nonsyndromic children. In addition, in number word and vowels discrimination test WS group showed slightly better performances, as well as in MUSS and MAIS assessment. Our study has shown that cochlear implantation should be considered a rehabilitative option for Waardenburg syndrome children with profound deafness, enabling the development and improvement of speech perception and production abilities in this group of patients, reinforcing their candidacy for this audio-oral rehabilitation method. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. Alternativas a la elevación de seno maxilar: implantes cortos Alternatives to maxillary sinus elevation: short implants

    Directory of Open Access Journals (Sweden)

    J. González Lagunas

    2008-12-01

    Full Text Available La mala calidad del hueso, reabsorciones extremas y la presencia de la cavidad del seno maxilar constituían obstáculos insalvables para la rehabilitación implanto-soportada en el sector posterior del maxilar atrófico. La elevación de seno es probablemente la primera opción de tratamiento en el paciente tributario de rehabilitación con implantes en ese sector. El uso de implantes cortos (menos de 10 mm se ha asociado tradicionalmente con unas tasas de supervivencia menores que la de los implantes largos. No obstante la aparición de nuevas superficies y diseños indican que este tipo de implantes puede soportar de forma fiable restauraciones dentales. Presentamos la técnica de instalación de implantes de superficie porosa sinterizada, asi como una revisión actualizada sobre el comportamiento de los implantes cortos.Poor bone quality, extreme bony resorption and a pneumatized mqxillary sinus are a severe Challenger for reconstruction of the atrophic edentuous posterior maxilla. Sinus lift is probably the gold standard for Management of that area. Short implants (<10mm have traditionally been associated with lower survival rates. The introduction of new surfaces and designs indicate that this type of implants can adequately support dental restorations. We present the technique of installation of sinterised porous dental implants together with an update on the behaviour of short implants.

  4. Impact of Different Surgeons on Dental Implant Failure.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    To assess the influence of several factors on the prevalence of dental implant failure, with special consideration of the placement of implants by different dental surgeons. This retrospective study is based on 2,670 patients who received 10,096 implants at one specialist clinic. Only the data of patients and implants treated by surgeons who had inserted a minimum of 200 implants at the clinic were included. Kaplan-Meier curves were stratified with respect to the individual surgeon. A generalized estimating equation (GEE) method was used to account for the fact that repeated observations (several implants) were placed in a single patient. The factors bone quantity, bone quality, implant location, implant surface, and implant system were analyzed with descriptive statistics separately for each individual surgeon. A total of 10 surgeons were eligible. The differences between the survival curves of each individual were statistically significant. The multivariate GEE model showed the following variables to be statistically significant: surgeon, bruxism, intake of antidepressants, location, implant length, and implant system. The surgeon with the highest absolute number of failures was also the one who inserted the most implants in sites of poor bone and used turned implants in most cases, whereas the surgeon with the lowest absolute number of failures used mainly modern implants. Separate survival analyses of turned and modern implants stratified for the individual surgeon showed statistically significant differences in cumulative survival. Different levels of failure incidence could be observed between the surgeons, occasionally reaching significant levels. Although a direct causal relationship could not be ascertained, the results of the present study suggest that the surgeons' technique, skills, and/or judgment may negatively influence implant survival rates.

  5. Dose perturbation in the presence of metallic implants: treatment planning system versus Monte Carlo simulations

    International Nuclear Information System (INIS)

    Wieslander, Elinore; Knoeoes, Tommy

    2003-01-01

    An increasing number of patients receiving radiation therapy have metallic implants such as hip prostheses. Therefore, beams are normally set up to avoid irradiation through the implant; however, this cannot always be accomplished. In such situations, knowledge of the accuracy of the used treatment planning system (TPS) is required. Two algorithms, the pencil beam (PB) and the collapsed cone (CC), are implemented in the studied TPS. Comparisons are made with Monte Carlo simulations for 6 and 18 MV. The studied materials are steel, CoCrMo, Orthinox(a stainless steel alloy and registered trademark of Stryker Corporation), TiAlV and Ti. Monte Carlo simulated depth dose curves and dose profiles are compared to CC and PB calculated data. The CC algorithm shows overall a better agreement with Monte Carlo than the PB algorithm. Thus, it is recommended to use the CC algorithm to get the most accurate dose calculation both for the planning target volume and for tissues adjacent to the implants when beams are set up to pass through implants

  6. Dopant site location in dual-implanted GaP using (111) planar channeling

    International Nuclear Information System (INIS)

    Parikh, N.R.; Kao, C.T.; Lee, D.R.; Muse, J.; Swanson, M.L.; Venkatasubramanian, R.; Timmons, M.

    1990-01-01

    Previous studies have indicated that dual implantation can efficiently introduce group IV dopant onto selected sub-lattice sites in III--V compound semiconductors, thus enhancing electrical activation. The authors have studied this phenomenon in GaP using Rutherford Backscattering Spectroscopy (RBS) to determine the lattice location of Sn atoms. The authors used single crystals of GaP (100) which had been implanted at 400 degrees C with 120 Sn + following previously implanted 69 Ga + or 31 P + . Energies were selected for equivalent projected ranges, and all species were implanted with doses of 1 x 10 15 atoms/cm 2 . Asymmetry in the angular scan of the {111} planar channel was then used to determine the sub-lattice location of the implanted Sn. RBS results indicated that for all implants Sn atoms were substituting Ga and P sites equally. However, Hall effect measurements gave p type conduction for GaP implanted with Sn alone, while those with prior implants of Ga or P resulted in n-type conduction. RBS and Hall effect results are explained by a vacancy complex model

  7. Macro design morphology of endosseous dental implants.

    Science.gov (United States)

    Sahiwal, Indira G; Woody, Ronald D; Benson, Byron W; Guillen, Guillermo E

    2002-05-01

    The identification of dental implant bodies in patients without available records is a considerable problem due to increased patient mobility and to the large number of implant systems with different designs. The purpose of this study was to document the designs of selected implants to help clinicians identify these implants from their radiographic images. More than 50 implant manufacturers were contacted and asked to provide implants with dimensions as close as possible to 3.75 mm (diameter) x 10 mm (length). Forty-four implants were donated, separated into threaded and non-threaded categories, and further sorted into tapered and non-tapered categories. The implants were examined visually, and features on the entire circumference and length of each implant were recorded and categorized as coronal, midbody, or apical. A series of tables describe the 44 implants according to coronal, midbody, and apical features. The results of this project offer dentists basic knowledge of the design of selected dental implants. Such knowledge can aid the radiographic identification of these implants.

  8. Multicycle mechanical performance of titanium and stainless steel transpedicular spine implants.

    Science.gov (United States)

    Pienkowski, D; Stephens, G C; Doers, T M; Hamilton, D M

    1998-04-01

    This was a prospective in vitro study comparing titanium alloy and stainless steel alloy in transpedicular spine implants from two different manufactures. To compare the multicycle mechanical performance of these two alloys, used in each of two different implant designs. Transpedicular spine implants primarily have been manufactured from stainless steel, but titanium alloy offers imaging advantages. However, the notch sensitivity of titanium alloy has caused concern regarding how implants made from this material will compare in stiffness and fatigue life with implants made from stainless steel. Twenty-four implants (two alloys, two designs, six implants per group) were mounted in machined polyethylene wafers and repetitively loaded (up to 1 million cycles) from 80 N to 800 N using a 5-Hertz sinusoidal waveform. Load and displacement data were automatically and periodically sampled throughout the entire test. Implant stiffness increased with cycle load number, reached a steady state, then declined just before fatigue failure. Stiffness varied less in titanium transpedicular spine implants than in their stainless counterparts. All stainless steel implant types were stiffer (steady-state value, P titanium alloy counterparts. One titanium implant design failed with fewer (P stainless steel counterpart, whereas a stainless steel implant of another design failed with fewer (P titanium counterpart. Overall, fatigue life, i.e., the total number of load cycles until failure, was related to implant type (P implant material. A transpedicular spine implant's fatigue lifetime depends on both the design and the material and cannot be judged on material alone. Stainless steel implants are stiffer than titanium alloy implants of equal design and size; however, for those designs in which the fatigue life of the titanium alloy version is superior, enlargement of the implant's components can compensate for titanium's lower modulus of elasticity and result in an implant equally stiff

  9. Irradiation influence on Mylar and Makrofol induced by argon ions in a plasma immersion ion implantation system

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, A. [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); El-Saftawy, A.A., E-mail: aama1978@yahoo.com [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Aal, S.A. Abd El [Central Lab. for Elemental & Isotopic Analysis, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Ghazaly, M. El [Physiology Department, College of Medicine, Taif University, P.O. 888, Taif (Saudi Arabia); Physics Department, Faculty of Science, Zagazig University, P.O. 44519, Zagazig (Egypt)

    2015-08-30

    Highlights: • A home-built plasma immersion ion implantation system was tested in modifying surfaces. • Wettability modifications within the energy range 10 keV implantation are not investigated elsewhere, up to our knowledge. • The wettability of Mylar and Makrofol surface was enhanced by the dual effect of ion implantation and plasma treatment. • The improved wettability was found to depend on both surface roughness and chemistry. • The adhesive bonding and surface energy of the polymers are improved. - Abstract: Mylar and Makrofol polycarbonate polymers were irradiated by Ar ions in a plasma immersion ion implantation (PIII) system. The surface wettability of both polymers was investigated by employing the contact angle method. The measured contact angles were found to depend on the surface layer properties. Good wetting surfaces were found to depend not only on surface roughness but also on its chemistry that analyzed by Fourier transform infrared (FTIR) spectroscopy. Surfaces topography and roughness was investigated and correlated to their surface energy which studied with the aid of acid-base model for evaluating the improvement of surface wettability after irradiation. PIII improves polymers surface properties efficiently in a controllable way.

  10. Influence of implant number on the biomechanical behaviour of mandibular implant-retained/supported overdentures: a three-dimensional finite element analysis.

    Science.gov (United States)

    Liu, Jingyin; Pan, Shaoxia; Dong, Jing; Mo, Zhongjun; Fan, Yubo; Feng, Hailan

    2013-03-01

    The aim of this study was to evaluate strain distribution in peri-implant bone, stress in the abutments and denture stability of mandibular overdentures anchored by different numbers of implants under different loading conditions, through three-dimensional finite element analysis (3D FEA). Four 3D finite element models of mandibular overdentures were established, using between one and four Straumann implants with Locator attachments. Three types of load were applied to the overdenture in each model: 100N vertical and inclined loads on the left first molar and a 100N vertical load on the lower incisors. The biomechanical behaviours of peri-implant bone, implants, abutments and overdentures were recorded. Under vertical load on the lower incisors, the single-implant overdenture rotated over the implant from side to side, and no obvious increase of strain was found in peri-implant bone. Under the same loading conditions, the two-implant-retained overdenture showed more apparent rotation around the fulcrum line passing through the two implants, and the maximum equivalent stress in the abutments was higher than in the other models. In the three-implant-supported overdenture, no strain concentration was found in cortical bone around the middle implant under three loading conditions. Single-implant-retained mandibular overdentures do not show damaging strain concentration in the bone around the only implant and may be a cost-effective treatment option for edentulous patients. A third implant can be placed between the original two when patients rehabilitated by two-implant overdentures report constant and obvious denture rotation around the fulcrum line. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Diagnostic Principles of Peri-Implantitis: a Systematic Review and Guidelines for Peri-Implantitis Diagnosis Proposal

    Directory of Open Access Journals (Sweden)

    Ausra Ramanauskaite

    2016-09-01

    Full Text Available Objectives: To review and summarize the literature concerning peri-implantitis diagnostic parameters and to propose guidelines for peri-implantitis diagnosis. Material and Methods: An electronic literature search was conducted of the MEDLINE (Ovid and EMBASE databases for articles published between 2011 and 2016. Sequential screening at the title/abstract and full-text levels was performed. Systematic reviews/guidelines of consensus conferences proposing classification or suggesting diagnostic parameters for peri-implantitis in the English language were included. The review was recorded on PROSPERO system with the code CRD42016033287. Results: The search resulted in 10 articles that met the inclusion criteria. Four were papers from consensus conferences, two recommended diagnostic guidelines, three proposed classification of peri-implantitis, and one suggested an index for implant success. The following parameters were suggested to be used for peri-implantitis diagnosis: pain, mobility, bleeding on probing, probing depth, suppuration/exudate, and radiographic bone loss. In all of the papers, different definitions of peri-implantitis or implant success, as well as different thresholds for the above mentioned clinical and radiographical parameters, were used. Current evidence rationale for the diagnosis of peri-implantitis and classification based on consecutive evaluation of soft-tissue conditions and the amount of bone loss were suggested. Conclusions: Currently there is no single uniform definition of peri-implantitis or the parameters that should be used. Rationale for diagnosis and prognosis of peri-implantitis as well as classification of the disease is proposed.

  12. Using optical tweezers for measuring the interaction forces between human bone cells and implant surfaces: System design and force calibration

    International Nuclear Information System (INIS)

    Andersson, Martin; Madgavkar, Ashwin; Stjerndahl, Maria; Wu, Yanrong; Tan, Weihong; Duran, Randy; Niehren, Stefan; Mustafa, Kamal; Arvidson, Kristina; Wennerberg, Ann

    2007-01-01

    Optical tweezers were used to study the interaction and attachment of human bone cells to various types of medical implant materials. Ideally, the implant should facilitate cell attachment and promote migration of the progenitor cells in order to decrease the healing time. It is therefore of interest, in a controlled manner, to be able to monitor the cell adhesion process. Results from such studies would help foresee the clinical outcome of integrating medical implants. The interactions between two primary cell culture models, human gingival fibroblasts and bone forming human osteoblast cells, and three different implant materials, glass, titanium, and hydroxyapatite, were studied. A novel type of optical tweezers, which has a newly designed quadrant detector and a powerful 3 W laser was constructed and force calibrated using two different methods: one method in which the stiffness of the optical trap was obtained by monitoring the phase lag between the trap and the moved object when imposing a forced oscillation on the trapped object and another method in which the maximum trapping force was derived from the critical velocity at which the object escapes the trap. Polystyrene beads as well as cells were utilized for the calibrations. This is the first time that cells have been used directly for these types of force calibrations and, hence, direct measurements of forces exerted on cells can be performed, thus avoiding the difficulties often encountered when translating the results obtained from cell measurements to the calibrations obtained with reference materials. This more straightforward approach represents an advantage in comparison to established methods

  13. [Technical feasibility of the implantation of a monorail stent system into the renal arteries without pre-dilatation].

    Science.gov (United States)

    Neumann, C; Gschwendtner, M; Karnel, F; Mair, J; Dorffner, G; Dorffner, R

    2005-01-01

    To evaluate the technical feasibility of the implantation of the monorail RX Herculink system into the renal arteries without pre-dilatation. Forty-two patients (mean age 71 years) from four centers with a total of 44 renal artery stenoses underwent implantation of the RX Herculink stent. The mean grade of the stenosis was 83.8 %, the mean length 7.5 mm. The stenoses were ostial in 38 cases and in immediate proximity to the ostium in 6 cases. The mean follow-up-period was 57 weeks (24 - 176 weeks). In 42 cases, the implantation was successful without pre-dilatation. In 2 cases, pre-dilatation was carried out. In none of the cases, detachment of the stent from the balloon was observed. In one stenosis with a length of 17 mm, implantation of two stents was performed. In 9 cases, post-dilatation with a larger balloon or higher balloon pressure was necessary. Residual stenoses exceeding 30 % were not observed. Two patients developed local bleeding at the puncture site. During the follow-up, restenoses were observed in 5 stents after 26 to 126 weeks, which necessitated a second intervention in 3 cases (PTA in 2 cases, re-stenting in 1 case). The primary patency rate after 6 and 12 months was 0.92 +/- 0.056 according to Kaplan-Meier, the secondary patency rate after 6 and 12 months was 1.0 +/- 0.0. Implantation of the RX Herculink stent system into the renal arteries without pre-dilatation is technically feasible and safe. Even without pre-dilatation, the stent-system can be advanced through the stenosis without detachment. The complication rate is low. Our clinical results are comparable to previous studies.

  14. Neurofibromatosis type 2 and auditory brainstem implantation

    Institute of Scientific and Technical Information of China (English)

    XIAO Hong-jun; Dennis K.K. Au; Yau Hui; Chun-kuen Chow; Yiu-wah Fan; William Ignace Wei

    2007-01-01

    @@ Neurofibromatosis type 2 (NF-2) is one of the most common single gene disorders in the nervous system.For approximately 96% of patients with NF-2 present with bilateral Schwannomas involving the eighth cranial nerves, which may be accompanied by Schwannomas involving other cranial, spinal or peripheral nerves, NF-2 is also referred to as "bilateral acoustic neuromas".

  15. Comparison of external and internal implant-abutment connections for implant supported prostheses. A systematic review and meta-analysis.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Bonfante, Estevam Augusto; Santiago Júnior, Joel Ferreira; Pellizzer, Eduardo Piza

    2018-03-01

    The systematic review and meta-analysis aimed to answer the PICO question: "Do patients that received external connection implants show similar marginal bone loss, implant survival and complication rates as internal connection implants?". Meta-analyses of marginal bone loss, survival rates of implants and complications rates were performed for the included studies. Study eligibility criteria included (1) randomized controlled trials (RCTs) and/or prospective, (2) studies with at least 10 patients, (3) direct comparison between connection types and (4) publications in English language. The Cochrane risk of bias tool was used to assess the quality and risk of bias in RCTs, while Newcastle-Ottawa scale was used for non-RCTs. A comprehensive search strategy was designed to identify published studies on PubMed/MEDLINE, Scopus, and The Cochrane Library databases up to October 2017. The search identified 661 references. Eleven studies (seven RCTs and four prospective studies) were included, with a total of 530 patients (mean age, 53.93 years), who had received a total of 1089 implants (461 external-connection and 628 internal-connection implants). The internal-connection implants exhibited lower marginal bone loss than external-connection implants (PInternal connections had lower marginal bone loss when compared to external connections. However, the implant-abutment connection had no influence on the implant's survival and complication rates. Based on the GRADE approach the evidence was classified as very low to moderate due to the study design, inconsistency, and publication bias. Thus, future research is highly encouraged. Internal connection implants should be preferred over external connection implants, especially when different risk factors that may contribute to increased marginal bone loss are present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Prevalence of blood type A and risk of vascular complications following transcatheter aortic valve implantation.

    Science.gov (United States)

    Rofe, M-T; Shacham, Y; Steinvi, A; Barak, L; Hareuveni, M; Banai, S; Keren, G; Finkelstein, A; Shmilovich, H

    2016-05-01

    To assess the prevalence of blood type A among patients referred for transcatheter aortic valve implantation (TAVI) and whether it is related to vascular complications. Vascular complications following TAVI are associated with adverse outcomes. Various blood types, particularly type A, have been shown to be more prevalent in cardiovascular diseases and to be related to prognosis. The prevalence of various blood types in a cohort of 491 consecutive patients who underwent TAVI was compared with a control group of 6500 consecutive hospitalised patients. The prevalence and predictors of vascular complications and bleeding events were evaluated in the blood type A group and were compared with non-type A patients. The mean age of TAVI patients was 83 ± 6 years, and 40 % were males. Patients were divided into two groups: blood type A (n = 220) and non-type A (n = 271). Type A was significantly more prevalent in the TAVI group than in the control group (45 vs. 38 %, p = 0.023). Compared with the non-type A group, patients with blood type A had more major and fatal bleeding (14.5 vs. 8.1 %, p = 0.027) and more vascular complications (any vascular complication: 24.5 vs. 15.9 % p = 0.016; major vascular complications: 12.3 vs. 7 % p = 0.047). In a multivariable analysis, blood type A emerged as a significant and independent predictor for vascular complications and bleeding events. Blood type A is significantly more prevalent in TAVI patients than in the general population and is related to higher rates of vascular and bleeding complications.

  17. Zinc and phosphorus co-implantation in indium phosphide

    International Nuclear Information System (INIS)

    Yu, K.M.; Ridgway, M.C.

    1998-01-01

    Electrical activation and dopant diffusion in Zn-implanted InP after rapid thermal annealing have been investigated. For an as-implanted Zn concentration of ∼4x10 19 thinspcm -3 , only ∼7% of the implanted Zn atoms formed electrically active shallow acceptors following a 950thinsp degree C/5 s annealing cycle. The low activation was the result of rapid Zn out-diffusion emdash only ∼14% of the implanted dopant was retained after annealing. A significant enhancement in electrical activation and a reduction in Zn loss were achieved in Zn+P co-implanted samples which yielded a net hole concentration of ≤6x10 18 thinspcm -3 and >50% Zn retention. The saturation of the free hole concentration in Zn+P co-implanted samples was attributed to the formation of Zn interstitial donors and Group-V-related donor-type native defects. For comparison, Zn+Al and Zn+Al+P co-implanted samples were also examined to distinguish the relative influences of implantation-induced disorder and nonstoichiometry on electrical activation and dopant diffusion. For the given implant conditions, we found that nonstoichiometry was the dominant influence. copyright 1998 American Institute of Physics

  18. Depth dependent modification of optical constants arising from H+ implantation in n-type 4H-SiC measured using coherent acoustic phonons

    Directory of Open Access Journals (Sweden)

    Andrey Baydin

    2016-06-01

    Full Text Available Silicon carbide (SiC is a promising material for new generation electronics including high power/high temperature devices and advanced optical applications such as room temperature spintronics and quantum computing. Both types of applications require the control of defects particularly those created by ion bombardment. In this work, modification of optical constants of 4H-SiC due to hydrogen implantation at 180 keV and at fluences ranging from 1014 to 1016 cm−2 is reported. The depth dependence of the modified optical constants was extracted from coherent acoustic phonon spectra. Implanted spectra show a strong dependence of the 4H-SiC complex refractive index depth profile on H+ fluence. These studies provide basic insight into the dependence of optical properties of 4H silicon carbide on defect densities created by ion implantation, which is of relevance to the fabrication of SiC-based photonic and optoelectronic devices.

  19. Miniature Coplanar Implantable Antenna on Thin and Flexible Platform for Fully Wireless Intracranial Pressure Monitoring System

    Directory of Open Access Journals (Sweden)

    M. Waqas A. Khan

    2017-01-01

    Full Text Available Minimally invasive approach to intracranial pressure monitoring is desired for long-term diagnostics. The monitored pressure is transmitted outside the skull through an implant antenna. We present a new miniature (6 mm × 5 mm coplanar implant antenna and its integration on a sensor platform to establish a far-field data link for the sensor readout at distances of 0.5 to 1 meter. The implant antenna was developed using full-wave electromagnetic simulator and measured in a liquid phantom mimicking the dielectric properties of the human head. It achieved impedance reflection coefficient better than −10 dB from 2.38 GHz to 2.54 GHz which covers the targeted industrial, scientific, and medical band. Experiments resulted in an acceptable peak gain of approximately −23 dBi. The implant antenna was submerged in the liquid phantom and interfaced to a 0.5 mW voltage controlled oscillator. To verify the implant antenna performance as a part of the ICP monitoring system, we recorded the radiated signal strength using a spectrum analyzer. Using a half-wavelength dipole as the receiving antenna, we captured approximately −58.7 dBm signal at a distance of 1 m from the implant antenna which is well above for the reader with sensitivity of −80 dBm.

  20. Stress Distribution in Single Dental Implant System: Three-Dimensional Finite Element Analysis Based on an In Vitro Experimental Model.

    Science.gov (United States)

    Rezende, Carlos Eduardo Edwards; Chase-Diaz, Melody; Costa, Max Doria; Albarracin, Max Laurent; Paschoeto, Gabriela; Sousa, Edson Antonio Capello; Rubo, José Henrique; Borges, Ana Flávia Sanches

    2015-10-01

    This study aimed to analyze the stress distribution in single implant system and to evaluate the compatibility of an in vitro model with finite element (FE) model. The in vitro model consisted of Brånemark implant; multiunit set abutment of 5 mm height; metal-ceramic screw-retained crown, and polyurethane simulating the bone. Deformations were recorded in the peri-implant region in the mesial and distal aspects, after an axial 300 N load application at the center of the occlusal aspect of the crown, using strain gauges. This in vitro model was scanned with micro CT to design a three-dimensional FE model and the strains in the peri-implant bone region were registered to check the compatibility between both models. The FE model was used to evaluate stress distribution in different parts of the system. The values obtained from the in vitro model (20-587 με) and the finite element analysis (81-588 με) showed agreement among them. The highest stresses because of axial and oblique load, respectively were 5.83 and 40 MPa for the cortical bone, 55 and 1200 MPa for the implant, and 80 and 470 MPa for the abutment screw. The FE method proved to be effective for evaluating the deformation around single implant. Oblique loads lead to higher stress concentrations.

  1. Intra- and intersubject comparison of cochlear implant systems using the Esprit and the Tempo+ behind-the-ear speech processor.

    Science.gov (United States)

    Kompis, Martin; Jenk, Martin; Vischer, Mattheus W; Seifert, Eberhard; Häusler, Rudolf

    2002-12-01

    A patient with bilateral profound deafness was implanted with a Nucleus CI24M cochlear implant (CI) and used an Esprit behind-the-ear (BTE) speech processor. Thirteen months later, the implant had to be removed because of a cholesteatoma. As the same electrode could not be reinserted, a Medel combi40s CI was implanted in the same ear, and the patient used a Tempo+ BTE processor. After 1 year of use of the Combi40s/Tempo+ system, speech recognition was better and was rated better subjectively than with the CI24M/Esprit system. Speech recognition and subjective ratings were also assessed for two matched groups of nine CI users each, using either an Esprit or a Tempo+ processor. On average, speech recognition scores were higher for the group of Tempo+ users, but the difference was not statistically significant. Users of the Esprit processors rated their device higher in terms of cosmetic appearance and comfort of wearing.

  2. Endochondral vs. intramembranous demineralized bone matrices as implants for osseous defects.

    Science.gov (United States)

    Nidoli, M C; Nielsen, F F; Melsen, B

    1999-05-01

    This study focuses on the difference in regenerative capacity between endochondral and intramembranous demineralized bone matrices (DBMs) when implanted into bony defects. It also focuses on the possible influence of the type of skeletal recipient site (orthotopic or heterotopic). Of 34 Wistar rats, 10 served as a source of DBM, and 24 were divided into two groups of 12 animals. In group A identical defects were produced in the parietal bones, whereas in group B the defects were produced in each radius. The right defects were implanted with endochondral DBM and the left defects were implanted with intramembranous DBM. Descriptive and/or histomorphometric analyses were performed by means of light and polarized microscopy, and radiography (group B). Right and left data were compared to disclose differences in bone-healing capacity. The quantitative results demonstrated that endochondral DBM displays a greater regenerative capacity than intramembranous DBM when implanted heterotopically. The different clinical performances of endochondral and intramembranous bone grafts might be explained on the basis of the mechanical rather than the osteoinductive principle. The qualitative results suggest that the type of bone deposition induced by the DBMs is not related to the type of implanted DBM. Recipient site characteristics and/or environmental factors seem decisive in the occurrence of either types of ossification.

  3. [Dental implant restoration abutment selection].

    Science.gov (United States)

    Bin, Shi; Hao, Zeng

    2017-04-01

    An increasing number of implant restoration abutment types are produced with the rapid development of dental implantology. Although various abutments can meet different clinical demands, the selection of the appropriate abutment is both difficult and confusing. This article aims to help clinicians select the appropriate abutment by describing abutment design, types, and selection criteria.

  4. Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck.

    Science.gov (United States)

    Liu, Yang; Wang, Jiawei

    2017-11-01

    To review the influences and clinical implications of micro-gap and micro-motion of implant-abutment interface on marginal bone loss around the neck of implant. Literatures were searched based on the following Keywords: implant-abutment interface/implant-abutment connection/implant-abutment conjunction, microgap, micromotion/micromovement, microleakage, and current control methods available. The papers were then screened through titles, abstracts, and full texts. A total of 83 studies were included in the literature review. Two-piece implant systems are widely used in clinics. However, the production error and masticatory load result in the presence of microgap and micromotion between the implant and the abutment, which directly or indirectly causes microleakage and mechanical damage. Consequently, the degrees of microgap and micromotion further increase, and marginal bone absorption finally occurs. We summarize the influences of microgap and micromotion at the implant-abutment interface on marginal bone loss around the neck of the implant. We also recommend some feasible methods to reduce their effect. Clinicians and patients should pay more attention to the mechanisms as well as the control methods of microgap and micromotion. To reduce the corresponding detriment to the implant marginal bone, suitable Morse taper or hybrid connection implants and platform switching abutments should be selected, as well as other potential methods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Structural and magnetic properties of Mn-implanted Si

    International Nuclear Information System (INIS)

    Zhou Shengqiang; Potzger, K.; Zhang Gufei; Muecklich, A.; Eichhorn, F.; Schell, N.; Groetzschel, R.; Schmidt, B.; Skorupa, W.; Helm, M.; Fassbender, J.; Geiger, D.

    2007-01-01

    Structural and magnetic properties in Mn-implanted, p-type Si were investigated. High resolution structural analysis techniques such as synchrotron x-ray diffraction revealed the formation of MnSi 1.7 nanoparticles already in the as-implanted samples. Depending on the Mn fluence, the size increases from 5 nm to 20 nm upon rapid thermal annealing. No significant evidence is found for Mn substituting Si sites either in the as-implanted or annealed samples. The observed ferromagnetism yields a saturation moment of 0.21μ B per implanted Mn at 10 K, which could be assigned to MnSi 1.7 nanoparticles as revealed by a temperature-dependent magnetization measurement

  6. Low energy implantation of boron with decaborane ions

    Science.gov (United States)

    Albano, Maria Angela

    The goal of this dissertation was to determine the feasibility of a novel approach to forming ultra shallow p-type junctions (tens of nm) needed for future generations of Si MOS devices. In the new approach, B dopant atoms are implanted by cluster ions obtained by ionization of decaborane (B 10H14) vapor. An experimental ion implanter with an electron impact ion source and magnetic mass separation was built at the Ion Beam and Thin Film Research Laboratory at NJIT. Beams of B10Hx+ ions with currents of a few microamperes and energies of 1 to 12 keV were obtained and used for implantation experiments. Profiles of B and H atoms implanted in Si were measured by Secondary Ion Mass Spectroscopy (SIMS) before and after rapid thermal annealing (RTA). From the profiles, the junction depth of 57 nm (at 1018 cm-3 B concentration) was obtained with 12 keV decaborane ions followed by RTA. The dose of B atoms that can be implanted at low energy into Si is limited by sputtering as the ion beam sputters both the matrix and the implanted atoms. As the number of sputtered B atoms increases with the implanted dose and approaches the number of the implanted atoms, equilibrium of B in Si is established. This effect was investigated by comparison of the B dose calculated from the ion beam integration with B content in the sample measured by Nuclear Reaction Analysis (NRA). Maximum (equilibrium) doses of 1.35 x 1016 B cm -2 and 2.67 x 1016 B cm-2 were obtained at the beam energies of 5 and 12 keV, respectively. The problem of forming shallow p-type junctions in Si is related not only to implantation depth, but also to transient enhanced diffusion (TED). TED in Si implanted with B10Hx+ was measured on boron doping superlattice (B-DSL) marker layers. It was found that TED, following decaborane implantation, is the same as with monomer B+ ion implantation of equivalent energy and that it decreases with the decreasing ion energy. (Abstract shortened by UMI.)

  7. System overview of the fully implantable destination therapy--ReinHeart-total artificial heart.

    Science.gov (United States)

    Pelletier, Benedikt; Spiliopoulos, Sotirios; Finocchiaro, Thomas; Graef, Felix; Kuipers, Kristin; Laumen, Marco; Guersoy, Dilek; Steinseifer, Ulrich; Koerfer, Reiner; Tenderich, Gero

    2015-01-01

    Owing to the lack of suitable allografts, the demand for long-term mechanical circulatory support in patients with biventricular end-stage heart failure is rising. Currently available Total Artificial Heart (TAH) systems consist of pump units with only limited durability, percutaneous tubes and bulky external equipment that limit the quality of life. Therefore we are focusing on the development of a fully implantable, highly durable destination therapy total artificial heart. The ReinHeart-TAH system consists of a passively filling pump unit driven by a low-wear linear drive between two artificial ventricles, an implantable control unit and a compliance chamber. The TAH is powered by a transcutaneous energy transmission system. The flow distribution inside the ventricles was analysed by fluid structure interaction simulation and particle image velocimetry measurements. Along with durability tests, the hydrodynamic performance and flow balance capability were evaluated in a mock circulation loop. Animal trials are ongoing. Based on fluid structure interaction simulation and particle image velocimetry, blood stagnation areas have been significantly reduced. In the mock circulation loop the ReinHeart-TAH generated a cardiac output of 5 l/min at an operating frequency of 120 bpm and an aortic pressure of 120/80 mmHg. The highly effective preload sensitivity of the passively filling ventricles allowed the sensorless integration of the Frank Starling mechanism. The ReinHeart-TAH effectively replaced the native heart's function in animals for up to 2 days. In vitro and in vivo testing showed a safe and effective function of the ReinHeart-TAH system. This has the potential to become an alternative to transplantation. However, before a first-in-man implant, chronic animal trials still have to be completed. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. The KFKI 150 kV ion-implanter

    International Nuclear Information System (INIS)

    Pasztor, E.

    1976-09-01

    The description of the ion-implanter of 150 keV maximum energy designed and built in the Central Research Institute for Physics, Budapest is given. The implanter fulfils all technological and safety requirements of the industry. In addition to B,P and As other elements up to mass-number 76 can also be implanted by help of the Danfysik 911 type ion source. The 3x10 -6 Torr operational pressure is provided by three turbomolecular pumps. The maximum dose is 1 μCb/cm 2 min and to ensure uniformity of the implantation on the 100x105 mm 2 target area the ion beam is swept electrostatically. According to the testing experiments the inhomogenity can be taken to be +-1.3%. (Sz.N.Z.)

  9. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  10. Wireless microsensor network solutions for neurological implantable devices

    Science.gov (United States)

    Abraham, Jose K.; Whitchurch, Ashwin; Varadan, Vijay K.

    2005-05-01

    The design and development of wireless mocrosensor network systems for the treatment of many degenerative as well as traumatic neurological disorders is presented in this paper. Due to the advances in micro and nano sensors and wireless systems, the biomedical sensors have the potential to revolutionize many areas in healthcare systems. The integration of nanodevices with neurons that are in communication with smart microsensor systems has great potential in the treatment of many neurodegenerative brain disorders. It is well established that patients suffering from either Parkinson"s disease (PD) or Epilepsy have benefited from the advantages of implantable devices in the neural pathways of the brain to alter the undesired signals thus restoring proper function. In addition, implantable devices have successfully blocked pain signals and controlled various pelvic muscles in patients with urinary and fecal incontinence. Even though the existing technology has made a tremendous impact on controlling the deleterious effects of disease, it is still in its infancy. This paper presents solutions of many problems of today's implantable and neural-electronic interface devices by combining nanowires and microelectronics with BioMEMS and applying them at cellular level for the development of a total wireless feedback control system. The only device that will actually be implanted in this research is the electrodes. All necessary controllers will be housed in accessories that are outside the body that communicate with the implanted electrodes through tiny inductively-coupled antennas. A Parkinson disease patient can just wear a hat-system close to the implantable neural probe so that the patient is free to move around, while the sensors continually monitor, record, transmit all vital information to health care specialist. In the event of a problem, the system provides an early warning to the patient while they are still mobile thus providing them the opportunity to react and

  11. Usher syndrome and cochlear implantation.

    Science.gov (United States)

    Loundon, Natalie; Marlin, Sandrine; Busquet, Denise; Denoyelle, Françoise; Roger, Gilles; Renaud, Francis; Garabedian, Erea Noel

    2003-03-01

    To evaluate the symptoms leading to diagnosis and the quality of rehabilitation after cochlear implantation in Usher syndrome. Retrospective cohort study. ENT department of a tertiary referral hospital. Among 210 patients given an implantation in the Ear, Nose, and Throat department, 185 were congenitally deaf and 13 had Usher syndrome (7.0%). Five had a family history of Usher, and eight were sporadic cases. Eleven cases were Usher type I, one was Usher type III, and one was not classified. The age at implantation ranged from 18 months to 44 years (mean, 6 years 1 month). The mean follow-up was 52 months (range, 9 months to 9 years). All patients had audiophonological and clinical examination, computed tomography scan of the temporal bones, ophthalmologic examination with fundoscopy, and an electroretinogram. Cerebral magnetic resonance imaging and vestibular examination were performed in 9 of 13 and 10 of 13 cases, respectively. Logopedic outcome measured preimplant and postimplant closed- and open-set word recognition and oral expression at follow-up. The most frequent initial sign of Usher syndrome was delayed walking, with a mean age of 20 months. Among the 172 other congenitally deaf children with implants, when deafness was not associated with other neurologic disorders, the mean age at walking was 14 months (p < 0.001). The fundoscopy was always abnormal after the age of 5 years, and the electroretinogram was abnormal in all cases. Vestibular function was abnormal in all but one case (nonclassified). The computed tomography scan and the magnetic resonance imaging were always normal. Logopedic results with cochlear implants showed good perception skills in all but one case. The best perceptive results were obtained in children implanted before the age of 9 years. Oral language had significantly progressed in 9 of 13 at follow-up. There was no relation between the visual acuity and the logopedic results. The earliest clinical sign associated with deafness

  12. Fatigue induced changes in conical implant-abutment connections.

    Science.gov (United States)

    Blum, Kai; Wiest, Wolfram; Fella, Christian; Balles, Andreas; Dittmann, Jonas; Rack, Alexander; Maier, Dominik; Thomann, Ralf; Spies, Benedikt Christopher; Kohal, Ralf Joachim; Zabler, Simon; Nelson, Katja

    2015-11-01

    Based on the current lack of data and understanding of the wear behavior of dental two-piece implants, this study aims for evaluating the microgap formation and wear pattern of different implants in the course of cyclic loading. Several implant systems with different conical implant-abutment interfaces were purchased. The implants were first evaluated using synchrotron X-ray high-resolution radiography (SRX) and scanning electron microscopy (SEM). The implant-abutment assemblies were then subjected to cyclic loading at 98N and their microgap was evaluated after 100,000, 200,000 and 1 million cycles using SRX, synchrotron micro-tomography (μCT). Wear mechanisms of the implant-abutment connection (IAC) after 200,000 cycles and 1 million cycles were further characterized using SEM. All implants exhibit a microgap between the implant and abutment prior to loading. The gap size increased with cyclic loading with its changes being significantly higher within the first 200,000 cycles. Wear was seen in all implants regardless of their interface design. The wear pattern comprised adhesive wear and fretting. Wear behavior changed when a different mounting medium was used (brass vs. polymer). A micromotion of the abutment during cyclic loading can induce wear and wear particles in conical dental implant systems. This feature accompanied with the formation of a microgap at the IAC is highly relevant for the longevity of the implants. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  13. Object-Oriented Type Systems

    DEFF Research Database (Denmark)

    Schwartzbach, Michael Ignatieff; Palsberg, Jens

    a type system that generalizes and explains them. The theory is based on an idealized object-oriented language called BOPL (Basic Object Programming Language), containing common features of the above languages. A type system, type inference algorithm, and typings of inheritance and genericity......Object-Oriented Type Systems Jens Palsberg and Michael I. Schwartzbach Aarhus University, Denmark Type systems are required to ensure reliability and efficiency of software. For object-oriented languages, typing is an especially challenging problem because of inheritance, assignment, and late...... are provided for BOPL. Throughout, the results are related to the languages on which BOPL is based. This text offers advanced undergraduates and professional software developers a sound understanding of the key aspects of object-oriented type systems. All algorithms are implemented in a freely available...

  14. Wear at the Implant-Abutment Interface of Zirconia Abutments Manufactured by Three CAD/CAM Systems.

    Science.gov (United States)

    Pinheiro Tannure, Ana Luiza; Cunha, Alfredo Gonçalves; Borges Junior, Luiz Antônio; da Silva Concílio, Laís Regiane; Claro Neves, Ana Christina

    To evaluate the changes in the external-hexagon surface of the titanium (Ti) implant before and after mechanical cycling, when coupled with zirconia (Zr) abutments (A) manufactured by three computer-aided design/computer-aided manufacturing (CAD/CAM) systems (Neodent Digital, Zirkonzahn, and AmannGirrbach) and the ZrTi abutment manufactured by Neodent. Four groups were formed (n = 6): titanium implant with Zr AmannGirrbach abutment (AZrAG), with Zr Zirkonzahn abutment (AZrZ), with Zr Neodent abutment (AZrN), and with Zr abutment with infrastructure in Ti Neodent (AZrTiN). Standardized abutments were made from three identical abutments milled in wax. Images of the surface of each side of the hexagons of the implant were obtained by scanning electron microscopy, before and after mechanical cycling, to evaluate the parameters: (1) scratches in the hexagon face; (2) hexagon superior shoulder kneading; (3) hexagon shoulder wear; (4) alterations on the hexagon base; and (5) scratches on the hexagon top. The abutments were coupled with the implants, and Cr-Co crowns were cemented. The implant/abutment/crown assemblies were submitted to mechanical cycling (400 N, 8.0 Hz) for 1 million cycles. The observed changes were classified as follows: absence (0), mild (1), moderate (2), and severe (3). The results were analyzed using the Mann-Whitney, Kruskal-Wallis, and Dunn tests (P abutments, the AZrN group had shown more surface alterations. Among the Zr groups, AZrZ samples had shown the most altered surfaces, suggesting that alterations on the implant/Zr abutment hexagon surfaces are related to the abutment milled hexagon shape.

  15. Effects of recoil-implanted oxygen on depth profiles of defects and annealing processes in P{sup +}-implanted Si studied using monoenergetic positron beams

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Moriya, Tsuyoshi; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Kitano, Tomohisa; Watanabe, Masahito; Kawano, Takao; Suzuki, Ryoichi; Ohdaira, Toshiyuki; Mikado, Tomohisa

    1996-04-01

    Effects of oxygen atoms recoiled from SiO{sub 2} films on depth profiles of defects and annealing processes in P{sup +}-implanted Si were studied using monoenergetic positron beams. For an epitaxial Si specimen, the depth profile of defects was found to be shifted toward the surface by recoil implantation of oxygen atoms. This was attributed to the formation of vacancy-oxygen complexes and a resultant decrease in the diffusion length of vacancy-type defects. The recoiled oxygen atoms stabilized amorphous regions introduced by P{sup +}-implantation, and the annealing of these regions was observed after rapid thermal annealing (RTA) at 700degC. For a Czochralski-grown Si specimen fabricated by through-oxide implantation, the recoiled oxygen atoms introduced interstitial-type defects upon RTA below the SiO{sub 2}/Si interface, and such defects were dissociated by annealing at 1000degC. (author)

  16. The cool seal system: a practical solution to the shaft seal problem and heat related complications with implantable rotary blood pumps.

    Science.gov (United States)

    Yamazaki, K; Mori, T; Tomioka, J; Litwak, P; Antaki, J F; Tagusari, O; Koyanagi, H; Griffith, B P; Kormos, R L

    1997-01-01

    A critical issue facing the development of an implantable, rotary blood pump is the maintenance of an effective seal at the rotating shaft. Mechanical seals are the most versatile type of seal in wide industrial applications. However, in a rotary blood pump, typical seal life is much shorter than required for chronic support. Seal failure is related to adhesion and aggregation of heat denatured blood proteins that diffuse into the lubricating film between seal faces. Among the blood proteins, fibrinogen plays an important role due to its strong propensity for adhesion and low transition temperature (approximately 50 degrees C). Once exposed to temperature exceeding 50 degrees C, fibrinogen molecules fuse together by multi-attachment between heat denatured D-domains. This quasi-polymerized fibrin increases the frictional heat, which proliferates the process into seal failure. If the temperature of the seal faces is maintained well below 50 degrees C, a mechanical seal would not fail in blood. Based on this "Cool-Seal" concept, we developed a miniature mechanical seal made of highly thermally conductive material (SiC), combined with a recirculating purge system. A large supply of purge fluid is recirculated behind the seal face to augment convective heat transfer to maintain the seal temperature below 40 degrees C. It also cools all heat generating pump parts (motor coil, bearing, seal). The purge consumption has been optimized to virtually nil (seal system has now been incorporated into our intraventricular axial flow blood pump (IVAP) and newly designed centrifugal pump. Ongoing in vivo evaluation of these systems has demonstrated good seal integrity for more than 160 days. The Cool-Seal system can be applied to any type of rotary blood pump (axial, diagonal, centrifugal, etc.) and offers a practical solution to the shaft seal problem and heat related complications, which currently limit the use of implantable rotary blood pumps.

  17. Multi-scale modification of metallic implants with pore gradients, polyelectrolytes and their indirect monitoring in vivo.

    Science.gov (United States)

    Vrana, Nihal E; Dupret-Bories, Agnes; Chaubaroux, Christophe; Rieger, Elisabeth; Debry, Christian; Vautier, Dominique; Metz-Boutigue, Marie-Helene; Lavalle, Philippe

    2013-07-01

    Metallic implants, especially titanium implants, are widely used in clinical applications. Tissue in-growth and integration to these implants in the tissues are important parameters for successful clinical outcomes. In order to improve tissue integration, porous metallic implants have being developed. Open porosity of metallic foams is very advantageous, since the pore areas can be functionalized without compromising the mechanical properties of the whole structure. Here we describe such modifications using porous titanium implants based on titanium microbeads. By using inherent physical properties such as hydrophobicity of titanium, it is possible to obtain hydrophobic pore gradients within microbead based metallic implants and at the same time to have a basement membrane mimic based on hydrophilic, natural polymers. 3D pore gradients are formed by synthetic polymers such as Poly-L-lactic acid (PLLA) by freeze-extraction method. 2D nanofibrillar surfaces are formed by using collagen/alginate followed by a crosslinking step with a natural crosslinker (genipin). This nanofibrillar film was built up by layer by layer (LbL) deposition method of the two oppositely charged molecules, collagen and alginate. Finally, an implant where different areas can accommodate different cell types, as this is necessary for many multicellular tissues, can be obtained. By, this way cellular movement in different directions by different cell types can be controlled. Such a system is described for the specific case of trachea regeneration, but it can be modified for other target organs. Analysis of cell migration and the possible methods for creating different pore gradients are elaborated. The next step in the analysis of such implants is their characterization after implantation. However, histological analysis of metallic implants is a long and cumbersome process, thus for monitoring host reaction to metallic implants in vivo an alternative method based on monitoring CGA and different

  18. Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study

    Science.gov (United States)

    AUNMEUNGTONG, W.; KHONGKHUNTHIAN, P.; RUNGSIYAKULL, P.

    2016-01-01

    SUMMARY Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Materials and methods Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. Results There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Conclusions Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Clinical implications Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant

  19. Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study.

    Science.gov (United States)

    Aunmeungtong, W; Khongkhunthian, P; Rungsiyakull, P

    2016-01-01

    Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force.

  20. Complex diagnosis in dental implantation and potentialities of predicting the results of treatment

    International Nuclear Information System (INIS)

    Matveeva, A.I.; Kulakov, A.A.

    1995-01-01

    Experience gained by the implantation Department of Central Research Institute of Dentistry in many years showed that comprehensive clinical and laboratory examinations, including roentgenological examination, functional diagnosis and examination of the immunity system help detect all unfavorable local and general factors. In patients referred to the risk group implantation is possible after preoperative treatment. Designing of STOM-1 and STOM-2, as well as of UMR-1 software helped carry our the calculations using IBM PC and determine the optimal type of the graft, place of its introduction, and number of grafts, as well as calculate the optimal design of the prosthesis

  1. Penile prosthesis implant: scientific advances and technological innovations over the last four decades.

    Science.gov (United States)

    Chung, Eric

    2017-02-01

    Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades.

  2. A Wireless Magnetic Resonance Energy Transfer System for Micro Implantable Medical Sensors

    Directory of Open Access Journals (Sweden)

    Tianyang Yang

    2012-07-01

    Full Text Available Based on the magnetic resonance coupling principle, in this paper a wireless energy transfer system is designed and implemented for the power supply of micro-implantable medical sensors. The entire system is composed of the in vitro part, including the energy transmitting circuit and resonant transmitter coils, and in vivo part, including the micro resonant receiver coils and signal shaping chip which includes the rectifier module and LDO voltage regulator module. Transmitter and receiver coils are wound by Litz wire, and the diameter of the receiver coils is just 1.9 cm. The energy transfer efficiency of the four-coil system is greatly improved compared to the conventional two-coil system. When the distance between the transmitter coils and the receiver coils is 1.5 cm, the transfer efficiency is 85% at the frequency of 742 kHz. The power transfer efficiency can be optimized by adding magnetic enhanced resonators. The receiving voltage signal is converted to a stable output voltage of 3.3 V and a current of 10 mA at the distance of 2 cm. In addition, the output current varies with changes in the distance. The whole implanted part is packaged with PDMS of excellent biocompatibility and the volume of it is about 1 cm3.

  3. In Vitro Comparative Evaluation of Different Types of Impression Trays and Impression Materials on the Accuracy of Open Tray Implant Impressions: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Sonam Gupta

    2017-01-01

    Full Text Available Purpose. For a precise fit of multiple implant framework, having an accurate definitive cast is imperative. The present study evaluated dimensional accuracy of master casts obtained using different impression trays and materials with open tray impression technique. Materials and Methods. A machined aluminum reference model with four parallel implant analogues was fabricated. Forty implant level impressions were made. Eight groups (n=5 were tested using impression materials (polyether and vinylsiloxanether and four types of impression trays, two being custom (self-cure acrylic and light cure acrylic and two being stock (plastic and metal. The interimplant distances were measured on master casts using a coordinate measuring machine. The collected data was compared with a standard reference model and was statistically analyzed using two-way ANOVA. Results. Statistically significant difference (p0.05 was observed between varied stock and custom trays. Conclusions. The polyether impression material proved to be more accurate than vinylsiloxanether impression material. The rigid nonperforated stock trays, both plastic and metal, could be an alternative for custom trays for multi-implant impressions when used with medium viscosity impression materials.

  4. Evaluation of stabilization techniques for ion implant processing

    Science.gov (United States)

    Ross, Matthew F.; Wong, Selmer S.; Minter, Jason P.; Marlowe, Trey; Narcy, Mark E.; Livesay, William R.

    1999-06-01

    With the integration of high current ion implant processing into volume CMOS manufacturing, the need for photoresist stabilization to achieve a stable ion implant process is critical. This study compares electron beam stabilization, a non-thermal process, with more traditional thermal stabilization techniques such as hot plate baking and vacuum oven processing. The electron beam processing is carried out in a flood exposure system with no active heating of the wafer. These stabilization techniques are applied to typical ion implant processes that might be found in a CMOS production process flow. The stabilization processes are applied to a 1.1 micrometers thick PFI-38A i-line photoresist film prior to ion implant processing. Post stabilization CD variation is detailed with respect to wall slope and feature integrity. SEM photographs detail the effects of the stabilization technique on photoresist features. The thermal stability of the photoresist is shown for different levels of stabilization and post stabilization thermal cycling. Thermal flow stability of the photoresist is detailed via SEM photographs. A significant improvement in thermal stability is achieved with the electron beam process, such that photoresist features are stable to temperatures in excess of 200 degrees C. Ion implant processing parameters are evaluated and compared for the different stabilization methods. Ion implant system end-station chamber pressure is detailed as a function of ion implant process and stabilization condition. The ion implant process conditions are detailed for varying factors such as ion current, energy, and total dose. A reduction in the ion implant systems end-station chamber pressure is achieved with the electron beam stabilization process over the other techniques considered. This reduction in end-station chamber pressure is shown to provide a reduction in total process time for a given ion implant dose. Improvements in the ion implant process are detailed across

  5. Immediate and early function of Brånemark System implants placed in the esthetic zone: a 1-year prospective clinical multicenter study.

    Science.gov (United States)

    Maló, Paulo; Friberg, Bertil; Polizzi, Giovanni; Gualini, Federico; Vighagen, Torbjörn; Rangert, Bo

    2003-01-01

    Immediate/early implant function means great benefits for patients and therapists because treatment time and cost can be substantially reduced. This concept has become an accepted alternative for complete arch fixed restorations in the mandible, and clinical documentation is emerging for other indications. The purpose of this prospective clinical multicenter study was to evaluate the outcome of implants placed in incisor, canine, and premolar regions in maxillas or mandibles. Implants were loaded with provisional crowns and bridges on the same day or within a few days and were followed up for 1 year during function. Four centers treated 76 patients each in need of an implant-retained prosthesis in the anterior and premolar regions in the maxilla or mandible. A total of 116 titanium implants with machined surfaces (Brånemark System , Nobel Biocare AB, Gothenburg, Sweden) were placed: 74 in maxillas and 42 in mandibles. Eighty-seven prostheses were made, of which 63 were single crowns and 24 were bridges (supported by 53 splinted implants). Twenty-two implants in 14 patients were placed in fresh extraction sites. The goal with the preparation and insertion technique was to achieve good primary implant stability and a minimum implant insertion torque of 30 Ncm before the implant was completely seated. The occlusion was adjusted to eliminate direct contact with the provisional prostheses. After 6 months, the patients received their permanent prostheses. Sixty-seven patients were followed for 1 year. Five implants were lost in five patients, three in the maxilla and two in the mandible. Four of the lost implants were single-tooth replacements and one was splinted. The cumulative survival rate (CSR) was 95.7% for all implants after 1 year and 93.7% and 98.1% for single-tooth and splinted implants, respectively. There were no implant losses in the extraction sites. The CSR of 96% at 1 year indicates that immediate function of Brånemark System implants placed in incisor

  6. Evaluation of an infrared camera and X-ray system using implanted fiducials in patients with lung tumors for gated radiation therapy

    International Nuclear Information System (INIS)

    Willoughby, Twyla R.; Forbes, Alan R.; Buchholz, Daniel; Langen, Katja M.; Wagner, Thomas H.; Zeidan, Omar A.; Kupelian, Patrick A.; Meeks, Sanford L.

    2006-01-01

    Purpose: To report on the initial clinical use of a commercially available system to deliver gated treatment using implanted fiducials, in-room kV X-rays, and an infrared camera tracking system. Methods and Materials: ExacTrac Adaptive Gating from BrainLab is a localization system using infrared cameras and X-rays. Gating signals are the patient's breathing pattern obtained from infrared reflectors on the patient. kV X-rays of an implanted fiducial are synchronized to the breathing pattern. After localization and shift of the patient to isocenter, the breathing pattern is used to gate Radiation. Feasibility tests included localization accuracy, radiation output constancy, and dose distributions with gating. Clinical experience is reported on treatment of patients with small lung lesions. Results: Localization accuracy of a moving target with gating was 1.7 mm. Dose constancy measurements showed insignificant change in output with gating. Improvements of dose distributions on moving targets improved with gating. Eleven patients with lung lesions were implanted with 20 mm x 0.7 mm gold coil (Visicoil). The implanted fiducial was used to localize and treat the patients with gating. Treatment planning and repeat computed tomographic scans showed that the change in center of gross target volume (GTV) to implanted marker averaged 2.47 mm due in part to asymmetric tumor shrinkage. Conclusion: ExacTrac Adaptive Gating has been used to treat lung lesions. Initial system evaluation verified its accuracy and usability. Implanted fiducials are visible in X-rays and did not migrate

  7. Elders with implant overdentures: a 22-year clinical report.

    Science.gov (United States)

    Alsabeeha, Nabeel H M

    2012-09-01

    To report on the long-term survival and prosthodontic maintenance of two edentulous adults with mandibular overdentures supported by hydroxyapatite (HA)-coated implants. Mandibular implant overdentures are a successful treatment option with positive impact on the quality of life of elderly edentulous adults. Long-term survival of the implants requires continued rigorous prosthodontic maintenance. Two elderly edentulous adults with mandibular overdentures supported by 2 HA-coated implants were presented for prosthodontic rehabilitation after 22 years of placement. The implants were osseo-integrated and surviving at presentation based on accepted criteria. The mandibular implant overdentures suffered recurrent loss of retention and stability. Prosthodontic treatment involving the replacement of defective attachment systems and construction of new sets of mandibular implant overdentures opposing complete maxillary dentures is presented. The long-term survival of mandibular 2-implant overdentures requires continued prosthodontic maintenance. A conservative approach in the rehabilitation of two older edentulous adults with mandibular 2-implant overdentures was described including proper selection of attachment systems. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  8. Does antibiotic prophylaxis at implant placement decrease early implant failures? A Cochrane systematic review.

    Science.gov (United States)

    Esposito, Marco; Grusovin, Maria Gabriella; Loli, Vasiliki; Coulthard, Paul; Worthington, Helen V

    2010-01-01

    Marco Esposito is the first author of two of the included studies; however, he was not involved in the quality assessment of these trials. This review is based on a Cochrane systematic review entitled 'Interventions for replacing missing teeth: antibiotics at dental implant placement to prevent complications' published in The Cochrane Library (see http://www.cochrane.org for more information). Cochrane systematic reviews are regularly updated to include new research, and in response to comments and criticisms from readers. If you wish to comment on this review, please send your comments to the Cochrane website or to Marco Esposito. The Cochrane Library should be consulted for the most recent version of the review. The results of a Cochrane Review can be interpreted differently, depending on people's perspectives and circumstances. Please consider the conclusions presented carefully. They are the opinions of the review authors, and are not necessarily shared by the Cochrane Collaboration. To assess the beneficial or harmful effects of systemic prophylactic antibiotics at dental implant placement versus no antibiotic/placebo administration and, if antibiotics are of benefit, to find which type, dosage and duration is the most effective. The Cochrane Oral Health Group's Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE were searched up to 2 June 2010 for randomised controlled clinical trials (RCTs) with a follow-up of at least 3 months comparing the administration of various prophylactic antibiotic regimens versus no antibiotics to patients undergoing dental implant placement. Outcome measures were prosthesis failures, implant failures, postoperative infections and adverse events (gastrointestinal, hypersensitivity, etc.). Screening of eligible studies, assessment of the methodological quality of the trials and data extraction were conducted in duplicate and independently by two review authors. Meta-analyses were

  9. Implant-buccal plate distance as diagnostic parameter: a prospective cohort study on implant placement in fresh extraction sockets.

    Science.gov (United States)

    Capelli, Matteo; Testori, Tiziano; Galli, Fabio; Zuffetti, Francesco; Motroni, Alessandro; Weinstein, Roberto; Del Fabbro, Massimo

    2013-12-01

    The aim of this study is to investigate contour changes around immediate implants in fresh extraction sockets when different grafting procedures are performed, based on the distance between the external implant collar and the bony surface on the buccal plate (I-BP). A secondary aim is to assess the esthetic outcome via the implant esthetic score (IAS). This prospective cohort study was performed in three centers. Suitable patients to undergo implant placement in fresh extraction sockets were selected. Periodontal biotype, horizontal and vertical peri-implant bone defects, and dehiscences were assessed. Depending on I-BP, two types of grafting procedures were performed. In group A (I-BP sockets. No implant failed during the observation period. The mean follow-up was 25 months (range: 12 to 37 months). After 1 year of loading, group A showed a slight decrease in mean buccal volume, whereas group B had an increase in volume (P = 0.02). IAS was higher for group B than group A. When implants are placed immediately after tooth extraction, I-BP may represent a useful diagnostic parameter in choosing the most appropriate grafting procedure (IG versus IEG). In clinical cases in which the distance between implant surface and the buccal plate is <4 mm, the combination of internal and external grafting (IEG) is recommended to maintain the volume and the contour of the ridge and achieve a successful esthetic outcome.

  10. Cochlear implantation in children and adults in Switzerland.

    Science.gov (United States)

    Brand, Yves; Senn, Pascal; Kompis, Martin; Dillier, Norbert; Allum, John H J

    2014-02-04

    The cochlear implant (CI) is one of the most successful neural prostheses developed to date. It offers artificial hearing to individuals with profound sensorineural hearing loss and with insufficient benefit from conventional hearing aids. The first implants available some 30 years ago provided a limited sensation of sound. The benefit for users of these early systems was mostly a facilitation of lip-reading based communication rather than an understanding of speech. Considerable progress has been made since then. Modern, multichannel implant systems feature complex speech processing strategies, high stimulation rates and multiple sites of stimulation in the cochlea. Equipped with such a state-of-the-art system, the majority of recipients today can communicate orally without visual cues and can even use the telephone. The impact of CIs on deaf individuals and on the deaf community has thus been exceptional. To date, more than 300,000 patients worldwide have received CIs. In Switzerland, the first implantation was performed in 1977 and, as of 2012, over 2,000 systems have been implanted with a current rate of around 150 CIs per year. The primary purpose of this article is to provide a contemporary overview of cochlear implantation, emphasising the situation in Switzerland.

  11. Correlation Between Resonance Frequency Analysis and Bone Quality Assessments at Dental Implant Recipient Sites.

    Science.gov (United States)

    Fu, Min-Wen; Fu, Earl; Lin, Fu-Gong; Chang, Wei-Jeng; Hsieh, Yao-Dung; Shen, E-Chin

    To evaluate whether primary implant stability could be used to predict bone quality, the association between the implant stability quotient (ISQ) value and the bone type at the implant site was evaluated. Ninety-five implant sites in 50 patients were included. Bone type (categorized by Lekholm and Zarb) at the implant site was initially assessed using presurgical dental radiography. During the preparation of the implant site, a bone core specimen was carefully obtained. The bone type was assessed by tactile sensation during the drilling operation, according to the Misch criteria. The primary stability of the inserted implant was evaluated by resonance frequency analysis (RFA). The ISQ value was recorded. The bone core specimen was then examined by stereomicroscopy or microcomputed tomography (micro-CT), and the bone type was determined by the surface characteristics of the specimen, based on Lekholm and Zarb classification. Agreement between the bone quality assessed by the four methods (ie, presurgical radiography, tactile sensation, stereomicroscopy, and micro-CT) was tested by Cohen's kappa statistics, whereas the association between the ISQ value and the bone type was evaluated by the generalized linear regression model. The mean ISQ score was 72.6, and the score was significantly influenced by the maxillary or mandibular arch (P = .001). The bone type at the implant sites varied according to the assessment method. However, a significant influence of the arch was repeatedly noted when using radiography or tactile sensation. Among the four bone-quality assessment methods, a weak agreement existed only between stereomicroscopy and micro-CT, especially in the maxilla (κ = 0.469). A negative association between the ISQ value and the bone type assessed by stereomicroscopy or by micro-CT was significant in the maxilla, but not in the mandible, after adjustments for sex, age, and right/left side (P = .013 and P = .027 for stereomicroscopy and micro-CT, respectively

  12. MRI information for commonly used otologic implants: review and update.

    Science.gov (United States)

    Azadarmaki, Roya; Tubbs, Rhonda; Chen, Douglas A; Shellock, Frank G

    2014-04-01

    To review information on magnetic resonance imaging (MRI) issues for commonly used otologic implants. Manufacturing companies, National Library of Medicine's online database, and an additional online database (www.MRIsafety.com). A literature review of the National Library of Medicine's online database with focus on MRI issues for otologic implants was performed. The MRI information on implants provided by manufacturers was reviewed. Baha and Ponto Pro osseointegrated implants' abutment and fixture and the implanted magnet of the Sophono Alpha 1 and 2 abutment-free systems are approved for 3-Tesla magnetic resonance (MR) systems. The external processors of these devices are MR Unsafe. Of the implants tested, middle ear ossicular prostheses, including stapes prostheses, except for the 1987 McGee prosthesis, are MR Conditional for 1.5-Tesla (and many are approved for 3-Tesla) MR systems. Cochlear implants with removable magnets are approved for patients undergoing MRI at 1.5 Tesla after magnet removal. The MED-EL PULSAR, SONATA, CONCERT, and CONCERT PIN cochlear implants can be used in patients undergoing MRI at 1.5 Tesla with application of a protective bandage. The MED-EL COMBI 40+ can be used in 0.2-Tesla MR systems. Implants made from nonmagnetic and nonconducting materials are MR Safe. Knowledge of MRI guidelines for commonly used otologic implants is important. Guidelines on MRI issues approved by the US Food and Drug Administration are not always the same compared with other parts of the world. This monograph provides a current reference for physicians on MRI issues for commonly used otologic implants.

  13. Cardiac pacing systems and implantable cardiac defibrillators (ICDs): a radiological perspective of equipment, anatomy and complications

    Energy Technology Data Exchange (ETDEWEB)

    Burney, K. E-mail: apqz59@dsl.pipex.comk1511@hotmail.com; Burchard, F.; Papouchado, M.; Wilde, P

    2004-08-01

    Cardiac pacing is a proven and effective treatment in the management of many cardiac arrhythmias. Implantable cardiac defibrillators (ICDs) are beneficial for certain patient groups with a history of serious, recurrent ventricular dysrhythmias, with a high risk of sudden cardiac death. Pacemaker devices take many forms and are highly visible on the chest radiograph. The radiographic appearances of ICDs and pacemakers can be similar and are subject to similar complications. The anatomical approach to the implantation, the type of device used and anatomical variations will all affect the appearance of these devices on the chest film. Pacemaker complications identified radiographically include pneumothorax, lead malpositioning, lead displacement or fracture, fracture of outer conductor coil, loose connection between the lead and pacemaker connector block, lack of redundant loops in paediatric patients and excessive manipulation of the device by the patient (Twiddler's syndrome). This pictorial review highlights the role of chest radiography in the diagnosis of post-cardiac pacing and ICD insertion complications, as well as demonstrating the normal appearances of the most frequently implanted devices.

  14. Air Abrasive Disinfection of Implant Surfaces in a Simulated Model of Peri-Implantitis

    Science.gov (United States)

    2016-06-01

    may be higher in patients diagnosed with periodontal disease, systemic chronic disease such as diabetes or patients who smoke tobacco.9,10 One of...flora associated with peri-implantitis is similar to that found in chronic periodontitis .14 Gram-positive, facultative bacteria are normally...9):1490-5. 20. Heitz-Mayfield LJ, Lang NP. Comparative biology of chronic and aggressive periodontitis vs. peri-implantitis. Periodontol 2000

  15. Implantable enzyme amperometric biosensors.

    Science.gov (United States)

    Kotanen, Christian N; Moussy, Francis Gabriel; Carrara, Sandro; Guiseppi-Elie, Anthony

    2012-05-15

    The implantable enzyme amperometric biosensor continues as the dominant in vivo format for the detection, monitoring and reporting of biochemical analytes related to a wide range of pathologies. Widely used in animal studies, there is increasing emphasis on their use in diabetes care and management, the management of trauma-associated hemorrhage and in critical care monitoring by intensivists in the ICU. These frontier opportunities demand continuous indwelling performance for up to several years, well in excess of the currently approved seven days. This review outlines the many challenges to successful deployment of chronically implantable amperometric enzyme biosensors and emphasizes the emerging technological approaches in their continued development. The foreign body response plays a prominent role in implantable biotransducer failure. Topics considering the approaches to mitigate the inflammatory response, use of biomimetic chemistries, nanostructured topographies, drug eluting constructs, and tissue-to-device interface modulus matching are reviewed. Similarly, factors that influence biotransducer performance such as enzyme stability, substrate interference, mediator selection and calibration are reviewed. For the biosensor system, the opportunities and challenges of integration, guided by footprint requirements, the limitations of mixed signal electronics, and power requirements, has produced three systems approaches. The potential is great. However, integration along the multiple length scales needed to address fundamental issues and integration across the diverse disciplines needed to achieve success of these highly integrated systems, continues to be a challenge in the development and deployment of implantable amperometric enzyme biosensor systems. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla

    Directory of Open Access Journals (Sweden)

    Shrikar R Desai

    2013-01-01

    Full Text Available Aim: The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. Materials and Methods: A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45° to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. Results: The results of total deformation (micro-movement and Von mises stress were found to be lower for tapered long implant (10 mm than short implant (6 mm while using both vertical as well as oblique loading. Conclusion: Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.

  17. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

    Science.gov (United States)

    Desai, Shrikar R; Singh, Rika; Karthikeyan, I

    2013-09-01

    The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading. Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.

  18. Technical feasibility of the implantation of a monorail stent system into the renal arteries without pre-dilatation

    International Nuclear Information System (INIS)

    Neumann, C.; Dorffner, R.; Gschwendtner, M.; Karnel, F.; Mair, J.; Dorffner, G.

    2005-01-01

    Purpose: to evaluate the technical feasibility of the implantation of the monorail RX Herculink trademark system into the renal arteries without pre-dilatation. Materials and methods: forty-two patients (mean age 71 years) from four centers with a total of 44 renal artery stenoses underwent implantation of the RX Herculink trademark stent. The mean grade of the stenosis was 83.8%, the mean length 7.5 mm. The stenoses were ostial in 38 cases and in immediate proximity to the ostium in 6 cases. The mean follow-up-period was 57 weeks (24 - 176 weeks). Results: in 42 cases, the implantation was successful without pre-dilatation. In 2 cases, pre-dilatation was carried out. In none of the cases, detachment of the stent from the balloon was observed. In one stenosis with a length of 17 mm, implantation of two stents was performed. In 9 cases, post-dilatation with a larger balloon or higher balloon pressure was necessary. Residual stenoses exceeding 30% were not observed. Two patients developed local bleeding at the puncture site. During the follow-up, restenoses were observed in 5 stents after 26 to 126 weeks, which necessitated a second intervention in 3 cases (PTA in 2 cases, re-stenting in 1 case). The primary patency rate after 6 and 12 months was 0.92 ± 0.056 according to Kaplan-Meier, the secondary patency rate after 6 and 12 months was 1.0 ± 0.0. Conclusion: implantation of the RX Herculink trademark stent system into the renal arteries without pre-dilatation is technically feasible and safe. Even without pre-dilatation, the stent-system can be advanced through the stenosis without detachment. The complication rate is low. Our clinical results are comparable to previous studies. (orig.)

  19. Implantation activation annealing of Si-implanted gallium nitride at temperatures > 1,100 C

    International Nuclear Information System (INIS)

    Zolper, J.C.; Han, J.; Biefeld, R.M.

    1997-01-01

    The activation annealing of Si-implanted GaN is reported for temperatures from 1,100 to 1,400 C. Although previous work has shown that Si-implanted GaN can be activated by a rapid thermal annealing at ∼1,100 C, it was also shown that significant damage remained in the crystal. Therefore, both AlN-encapsulated and uncapped Si-implanted GaN samples were annealed in a metal organic chemical vapor deposition system in a N 2 /NH 3 ambient to further assess the annealing process. Electrical Hall characterization shows increases in carrier density and mobility for annealing up to 1,300 C before degrading at 1,400 C due to decomposition of the GaN epilayer. Rutherford backscattering spectra show that the high annealing temperatures reduce the implantation induced damage profile but do not completely restore the as-grown crystallinity

  20. Mutation effect of ion implantation on tomato breeding

    International Nuclear Information System (INIS)

    Wu Baoshan; Ling Haiqiu; Mao Peihong; Jin Xiang; Zeng Xianxian

    2003-01-01

    The mutation effects of N + ion implantation on cultivated tomato, Catchup type and Eatable type were studied. The result show that the mutation ranges of single-fruit weight and fruit number per plant were increased and their mutation frequencies were high, however the effect of ion implantation on germination rate of seed and quality of fruit was very weak. Using doses of 4 x 10 16 and 6 x 10 16 N + /cm 2 , the yield was greatly improved. The optimum mutation dosage was slightly different for seed of 2 tomato lines

  1. Plasma Immersion Ion Implantation in Radio Frequency Plasma

    International Nuclear Information System (INIS)

    Bora, B.; Bhuyan, H.; Wyndham, E.

    2013-01-01

    Plasma immersion ion implantation (PIII) has attracted wide interests since it emulates conventional ion-beam ion implantation (IBII) in niche applications. For instance, the technique has very high throughput, the implantation time is independent of the sample size, and samples with an irregular shape can be implanted without complex beam scanning or sample manipulation. For uniform ion implantation and deposition on to different substrates, like silicon, stainless steel etc., a capacitive coupled Radio frequency (RF), 13.6 MHz, plasma is used. During the PIII process, the physical parameters which are expected to play crucial rule in the deposition process like RF power, Negative pulse voltage and pulse duration, gas type and gas mixture, gas flow rates and the implantation dose are studied. The ion dose is calculated by dynamic sheath model and the plasma parameters are calculated from the V-I characteristic and power balance equation by homogeneous model of rf plasma discharge considering Ohmic as well as Stochastic heating. The correlations between the yield of the implantation process and the physical parameters as well as plasma parameters are discussed. (author)

  2. Effects of mechanical repetitive load on bone quality around implants in rat maxillae.

    Directory of Open Access Journals (Sweden)

    Yusuke Uto

    Full Text Available Greater understanding and acceptance of the new concept "bone quality", which was proposed by the National Institutes of Health and is based on bone cells and collagen fibers, are required. The novel protein Semaphorin3A (Sema3A is associated with osteoprotection by regulating bone cells. The aims of this study were to investigate the effects of mechanical loads on Sema3A production and bone quality based on bone cells and collagen fibers around implants in rat maxillae. Grade IV-titanium threaded implants were placed at 4 weeks post-extraction in maxillary first molars. Implants received mechanical loads (10 N, 3 Hz for 1800 cycles, 2 days/week for 5 weeks from 3 weeks post-implant placement to minimize the effects of wound healing processes by implant placement. Bone structures, bone mineral density (BMD, Sema3A production and bone quality based on bone cells and collagen fibers were analyzed using microcomputed tomography, histomorphometry, immunohistomorphometry, polarized light microscopy and birefringence measurement system inside of the first and second thread (designated as thread A and B, respectively, as mechanical stresses are concentrated and differently distributed on the first two threads from the implant neck. Mechanical load significantly increased BMD, but not bone volume around implants. Inside thread B, but not thread A, mechanical load significantly accelerated Sema3A production with increased number of osteoblasts and osteocytes, and enhanced production of both type I and III collagen. Moreover, mechanical load also significantly induced preferential alignment of collagen fibers in the lower flank of thread B. These data demonstrate that mechanical load has different effects on Sema3A production and bone quality based on bone cells and collagen fibers between the inside threads of A and B. Mechanical load-induced Sema3A production may be differentially regulated by the type of bone structure or distinct stress distribution

  3. Type Systems for Bigraphs

    DEFF Research Database (Denmark)

    Elsborg, Ebbe; Hildebrandt, Thomas; Sangiorgi, Davide

    of controls and a set of reaction rules, collectively a bigraphical reactive system (BRS). Possible advantages of developing bigraphical type systems include: a deeper understanding of a type system itself and its properties; transfer of the type systems to the concrete family of calculi that the BRS models...

  4. [Total cervical disk replacement--implant-specific approaches: keel implant (Prodisc-C intervertebral disk prosthesis)].

    Science.gov (United States)

    Korge, Andreas; Siepe, Christoph J; Heider, Franziska; Mayer, H Michael

    2010-11-01

    Dynamic intervertebral support of the cervical spine via an anterolateral approach using a modular artificial disk prosthesis with end-plate fixation by central keel fixation. Cervical median or mediolateral disk herniations, symptomatic cervical disk disease (SCDD) with anterior osseous, ligamentous and/or discogenic narrowing of the spinal canal. Cervical fractures, tumors, osteoporosis, arthrogenic neck pain, severe facet degeneration, increased segmental instability, ossification of posterior longitudinal ligament (OPLL), severe osteopenia, acute and chronic systemic, spinal or local infections, systemic and metabolic diseases, known implant allergy, pregnancy, severe adiposity (body mass index > 36 kg/m2), reduced patient compliance, alcohol abuse, drug abuse and dependency. Exposure of the anterior cervical spine using the minimally invasive anterolateral approach. Intervertebral fixation of retainer screws. Intervertebral diskectomy. Segmental distraction with vertebral body retainer and vertebral distractor. Removal of end-plate cartilage. Microscopically assisted decompression of spinal canal. Insertion of trial implant to determine appropriate implant size, height and position. After biplanar image intensifier control, drilling for keel preparation using drill guide and drill bit, keel-cut cleaner to remove bone material from the keel cut, radiologic control of depth of the keel cut using the corresponding position gauge. Implantation of original implant under lateral image intensifier control. Removal of implant inserter. Functional postoperative care and mobilization without external support, brace not used routinely, soft brace possible for 14 days due to postoperative pain syndromes. Implantation of 100 cervical Prodisc-C disk prostheses in 78 patients (average age 48 years) at a single center. Clinical and radiologic follow-up 24 months postoperatively. Significant improvement based on visual analog scale and Neck Disability Index. Radiologic

  5. Practical considerations for the implantation of a fuzzy control algorithm in a DSP

    International Nuclear Information System (INIS)

    Perez C, B.; Benitez R, J.S.; Pacheco S, J.O.

    2003-01-01

    The development of a digital system based on a DSP to implant a Mamdani type algorithm of fuzzy control whose objective is to regulate the neutron power in a nuclear research reactor Type TRIGA Mark III is presented. Its are simultaneously carried out the aggregation des fuzzy stages discreeting the universe of the output variable. The format MPF for the handling of the floating point in the arithmetic operations is used. (Author)

  6. PAIN RELIEF MEDIATED BY IMPLANTABLE DRUG-DELIVERY DEVICES

    NARCIS (Netherlands)

    HOEKSTRA, A

    Various totally implantable drug delivery systems from single access ports to micropumps are now available for administration of repeated boluses, and continuous or programmable infusions. In this respect, emphasis is given to a relatively cheap, totally implantable system for self-administering

  7. Comparison of marginal bone loss between internal- and external-connection dental implants in posterior areas without periodontal or peri-implant disease.

    Science.gov (United States)

    Kim, Dae-Hyun; Kim, Hyun Ju; Kim, Sungtae; Koo, Ki-Tae; Kim, Tae-Il; Seol, Yang-Jo; Lee, Yong-Moo; Ku, Young; Rhyu, In-Chul

    2018-04-01

    The purpose of this retrospective study with 4-12 years of follow-up was to compare the marginal bone loss (MBL) between external-connection (EC) and internal-connection (IC) dental implants in posterior areas without periodontal or peri-implant disease on the adjacent teeth or implants. Additional factors influencing MBL were also evaluated. This retrospective study was performed using dental records and radiographic data obtained from patients who had undergone dental implant treatment in the posterior area from March 2006 to March 2007. All the implants that were included had follow-up periods of more than 4 years after loading and satisfied the implant success criteria, without any peri-implant or periodontal disease on the adjacent implants or teeth. They were divided into 2 groups: EC and IC. Subgroup comparisons were conducted according to splinting and the use of cement in the restorations. A statistical analysis was performed using the Mann-Whitney U test for comparisons between 2 groups and the Kruskal-Wallis test for comparisons among more than 2 groups. A total of 355 implants in 170 patients (206 EC and 149 IC) fulfilled the inclusion criteria and were analyzed in this study. The mean MBL was 0.47 mm and 0.15 mm in the EC and IC implants, respectively, which was a statistically significant difference ( P <0.001). Comparisons according to splinting (MBL of single implants: 0.34 mm, MBL of splinted implants: 0.31 mm, P =0.676) and cement use (MBL of cemented implants: 0.27 mm, MBL of non-cemented implants: 0.35 mm, P =0.178) showed no statistically significant differences in MBL, regardless of the implant connection type. IC implants showed a more favorable bone response regarding MBL in posterior areas without peri-implantitis or periodontal disease.

  8. Chewing efficiency and maximum bite force with different attachment systems of implant overdentures: a crossover study.

    Science.gov (United States)

    Elsyad, Moustafa Abdou; Khairallah, Ahmed Samir

    2017-06-01

    This crossover study aimed to evaluate and compare chewing efficiency and maximum bite force (MBF) with resilient telescopic and bar attachment systems of implant overdentures in patients with atrophied mandibles. Ten participants with severely resorbed mandibles and persistent denture problems received new maxillary and mandibular conventional dentures (control, CD). After 3 months of adaptation, two implants were inserted in canine region of the mandible. In a quasi-random method, overdentures were connected to the implants with either bar overdentures (BOD) or resilient telescopic overdentures (TOD) attachment systems. Chewing efficiency in terms of unmixed fraction (UF) was measured using chewing gum (after 5, 10, 20, 30 and 50 strokes), and MBF was measured using a bite force transducer. Measurements were performed 3 months after using each of the following prostheses: CD, BOD and TOD. Chewing efficiency and MBF increased significantly with BOD and TOD compared to CD. As the number of chewing cycles increased, the UF decreased. TOD recorded significant higher chewing efficiency and MBF than BOD. Resilient telescopic attachments are associated with increased chewing efficiency and MBF compared bar attachments when used to retain overdentures to the implants in patients with atrophied mandibles. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. The effect of ions on the magnetic moment of vacancy for ion-implanted 4H-SiC

    Science.gov (United States)

    Peng, B.; Zhang, Y. M.; Dong, L. P.; Wang, Y. T.; Jia, R. X.

    2017-04-01

    The structural properties and the spin states of vacancies in ion implanted silicon carbide samples are analyzed by experimental measurements along with first-principles calculations. Different types and dosages of ions (N+, O+, and B+) were implanted in the 4H-silicon carbide single crystal. The Raman spectra, positron annihilation spectroscopy, and magnetization-magnetic field curves of the implanted samples were measured. The fitting results of magnetization-magnetic field curves reveal that samples implanted with 1 × 1016 cm-2 N+ and O+ ions generate paramagnetic centers with various spin states of J = 1 and J = 0.7, respectively. While for other implanted specimens, the spin states of the paramagnetic centers remain unchanged compared with the pristine sample. According to the positron annihilation spectroscopy and first-principles calculations, the change in spin states originates from the silicon vacancy carrying a magnetic moment of 3.0 μB in the high dosage N-implanted system and 2.0 μB in the O-doped system. In addition, the ratio of the concentration of implanted N ions and silicon vacancies will affect the magnetic moment of VSi. The formation of carbon vacancy which does not carry a local magnetic moment in B-implanted SiC can explain the invariability in the spin states of the paramagnetic centers. These results will help to understand the magnetic moments of vacancies in ion implanted 4H-SiC and provide a possible routine to induce vacancies with high spin states in SiC for the application in quantum technologies and spintronics.

  10. The impact of glucocorticosteroids administered for systemic diseases on the osseointegration and survival of dental implants placed without bone grafting-A retrospective study in 31 patients.

    Science.gov (United States)

    Petsinis, Vassilis; Kamperos, Georgios; Alexandridi, Foteini; Alexandridis, Konstantinos

    2017-08-01

    To evaluate the impact of glucocorticosteroids, administered for the treatment of systemic diseases, on the osseointegration and survival of dental implants placed without bone grafting. A retrospective study was conducted in search of patients treated with dental implants while receiving glucocorticosteroid therapy for various systemic diseases. In these cases, a conventional two-stage surgical protocol was used, without bone regeneration procedures. The osseointegration was clinically and radiographically tested at the uncovering of the implants. The follow-up after loading was set at a minimum of 3 years. A total of 31 patients were included in the study. Of the 105 dental implants placed, 104 were osseointegrated (99%). No bone absorption was radiographically noted at the uncovering of the osseointegrated implants. All of the osseointegrated implants were successfully loaded for the prosthetic restoration. The mean follow-up period after loading was 71 months, with an implant survival rate of 99%. Glucocorticosteroid intake for systemic diseases does not have a significant impact on the osseointegration and the 3-year survival of dental implants placed with a conventional two-stage surgical protocol and without bone grafting. Therefore, it should not be considered a contraindication for dental implant placement. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  11. Field isolation for GaN MOSFETs on AlGaN/GaN heterostructure with boron ion implantation

    International Nuclear Information System (INIS)

    Jiang, Y; Wang, Q P; Wang, D J; Tamai, K; Li, L A; Ao, J-P; Ohno, Y; Shinkai, S; Miyashita, T; Motoyama, S-I

    2014-01-01

    We report the investigation of boron ion implantation as a device field isolation process for GaN metal-oxide-semiconductor field-effect transistors (MOSFETs) on AlGaN/GaN heterostructure. In the mesa isolation region of a bar-type MOSFET, a parasitic MOS-channel existed and widened the designed channel width, which would result in an overestimated mobility compared with a ring-type MOSFET. After boron ions implantation in the isolation region, the overestimation of field-effect mobility of bar-type MOSFETs was eliminated. The sub-threshold characteristics and on-state drain current of the bar-type MOSFETs coincide with the ring-type devices. Long-channel ring-type MOSFETs, with and without ion implantation, were fabricated on the recess region to evaluate the sub-threshold characteristics. The MOSFETs with boron ions implanted into the recess region showed a low drain current up to the gate bias of 10V. The result indicated that boron ion implantation prevented the formation of parasitic MOS-channel in the isolation region and achieved field isolation. The current–voltage characteristics of MOSFETs with the normal recess condition demonstrated no degradation of device performance after boron ions implanted into the isolation region. Boron ion implantation by further optimization can be a field isolation method for GaN MOSFETs. (paper)

  12. Doping of GaN by ion implantation: Does It Work?

    International Nuclear Information System (INIS)

    Suvkhanov, A.; Wu, W.; Price, K.; Parikh, N.; Irene, E.; Hunn, J.; Thomson, D.; Davis, R.F.; Krasnobaev, L.

    1998-04-01

    Epitaxially grown GaN by metal organic chemical vapor deposition (MOCVD) on SiC were implanted with 100 keV Si + (for n-type) and 80 keV Mg + (for p-type) with various fluences from 1 x 10 12 to 7 x 10 15 ions/cm 2 at liquid nitrogen temperature (LT), room temperature (RT), and 700 C (HT). High temperature (1,200 C and 1,500 C) annealing was carried out after capping the GaN with epitaxial AlN by MOCVD to study damage recovery. Samples were capped by a layer of AlN in order to protect the GaN surface during annealing. Effects of implant temperature, damage and dopant activation are critically studied to evaluate a role of ion implantation in doping of GaN. The damage was studied by Rutherford Backscattering/Channeling, spectroscopic ellipsometry and photoluminescence. Results show dependence of radiation damage level on temperature of the substrate during implantation: implantations at elevated temperatures up to 550 C decrease the lattice disorder; hot implants above 550 C can not be useful in doping of GaN due to nitrogen loss from the surface. SE measurements have indicated very high sensitivity to the implantation damage. PL measurements at LT of 80 keV Mg + (5 x 10 14 cm 2 ) implanted and annealed GaN showed two peaks: one ∼ 100 meV and another ∼ 140 meV away from the band edge

  13. Scintigraphic examinations after stent implantation in central airways

    International Nuclear Information System (INIS)

    Richter, W.S.; Kettner, B.I.; Munz, D.L.

    1998-01-01

    Endotracheal and endobronchial stent implantation has been developed as an effective treatment of benign and malignant airway stenosis and of tracheo- or bronchoesophageal fistulas. The selection of the stent type depends on the kind and site of disease. Chest X-ray and bronchoscopy are the procedures of choice for monitoring of stent position, structure, and function. However, with scintigraphic methods the effects of stent implantation on pulmonary ventilation and perfusion can be assessed non-invasively. The validation of the effect of a stent implantation on mucociliary and tussive clearance remains to be elucidated. (orig.) [de

  14. Integration of Resonant Coil for Wireless Power Transfer and Implantable Antenna for Signal Transfer

    Directory of Open Access Journals (Sweden)

    Dong-Wook Seo

    2016-01-01

    Full Text Available We propose the integration of the resonant coil for wireless power transfer (WPT and the implantable antenna for physiological signal transfer. The integration allows for a compact biomedical implantable system such as electrocardiogram (ECG recorder and pacemaker. While the resonant coils resonate at the frequency of 13.56 MHz for the WPT, the implantable antenna works in the medical implant communications service (MICS band of 402–405 MHz for wireless communications. They share the narrow substrate area of a bar-type shape; the coil has the current path on the outer part of the substrate and the meandered planar inverted-F antenna (PIFA occupies the inside of the coil. To verify the potentials of the proposed structure, a prototype is fabricated and tested in vitro. The power transfer efficiency (PTE of about 20% is obtained at a distance of 15 mm and the antenna gain of roughly −40 dBi is achieved.

  15. [Influence of attachment type on stress distribution of implant-supported removable partial dentures].

    Science.gov (United States)

    Yang, Xue; Rong, Qi-guo; Yang, Ya-dong

    2015-02-18

    To compare influences of different retention attachments on stress among supporting structures. By 3-dimensional laser scanner and reverse engineering computer aided design (CAD) software, a basic partially edentulous digital model with mandibular premolar and molar missing was established. Implant attachment and removable partial dentures (RPD) were added into the basic model to build three kinds of models: RPD only, RPD + implant + Locator attachment, and RPD + implant + Magfit attachment. Vertical and inclined loads were put on artificial teeth unilaterally. By means of 3-dimensional finite element analysis, the stress distribution and displacement of the main supportive structures were compared. A complete 3-dimensional finite element model was established, which contained tooth structure, and periodontal structures. The displacement of the denture was smaller in Locator (9.38 μm vertically, 45.48 μm obliquely) and Magfit models (9.54 μm vertically, 39.45 μm obliquely) compared with non-implant RPD model (95.27 μm vertically, 155.70 μm obliquely). Compared with the two different attachments, cortical bone stress value was higher in Locator model (Locator model 10.850 MPa vertically, 43.760 MPa obliquely; Magfit model 7.100 MPa vertically, 19.260 MPa obliquely).The stress value of abutment periodontal ligamentin Magfit model (0.420 MPa vertically) was lower than that in Locator model (0.520 MPa vertically). The existence of implant could reduce maximum von Mises value of each supportive structure when Kennedy I partially edentulous mandible was restored. Comparing the structure of Magfit and Locator attachment, the contact of Magfit attachment was rigid, while Locator was resilient. Locator attachment could improve stability of the denture dramatically. Locator had stronger effect on defending horizontal movement of the denture.

  16. Successful bone-anchored hearing aid implantation in a patient with osteogenesis imperfecta.

    Science.gov (United States)

    Coutinho, M B; Marques, C; Mendes, G J; Gonçalves, C

    2015-11-01

    To report a case of successful bone-anchored hearing aid implantation in an adult patient with type III osteogenesis imperfecta, which is commonly regarded as a contraindication to this procedure. A 45-year-old man with type III osteogenesis imperfecta presented with mixed hearing loss. There was a mild sensorineural component in both ears, with an air-bone gap between 45 and 50 dB HL. He was implanted with a bone-anchored hearing aid. The audiological outcome was good, with no complications and good implant stability (as measured by resonance frequency analysis). To our knowledge, this is the first recorded case of bone-anchored hearing aid implantation in a patient with osteogenesis imperfecta.

  17. Quality of Life of Patients Treated With Implant-Supported Mandibular Overdentures Evaluated With the Oral Health Impact Profile (OHIP-14: a Survey of 58 Patients

    Directory of Open Access Journals (Sweden)

    Ritva Kuoppala

    2013-06-01

    Full Text Available Objectives: The purpose of this study was to evaluate the oral health-related quality of life of patients treated with implant-supported mandibular overdentures and to compare the attachment systems used.Material and Methods: Altogether 112 patients treated with implant-supported mandibular overdentures in 1985 - 2004 were invited to the follow-up; 58 of them attended and replied to the Oral Health Impact Profile (OHIP-14 -questionnaire. There were 48 overdentures with a bar connection and 10 with a ball connection, the total number of implants installed and still in use was 197. The mean follow-up time was 13.7 years. The associations between the OHIP-14 variables and the patient’s age, gender as well as the number of implants supporting the overdenture and the type of attachment used were assessed.Results: The results showed that patients with implant-supported mandibular overdentures were satisfied with their oral health-related quality of life (OHRQoL. Older patients were more satisfied than younger ones in both genders. Neither the implant connection type nor the number of supporting implants seemed to have a significant influence on the OHRQoL.Conclusions: Especially older patients with mandibular implant-supported overdentures were satisfied with their oral health-related quality of life. Attachment type or the number of supporting implants did not have a significant influence on the oral health-related quality of life.

  18. ESR studies of high-energy phosphorus-ion implanted synthetic diamond crystals

    Energy Technology Data Exchange (ETDEWEB)

    Isoya, J [University of Library and Information Science, Tsukuba, Ibaraki (Japan); Kanda, H; Morita, Y; Ohshima, T

    1997-03-01

    Phosphorus is among potential n-type dopants in diamond. High pressure synthetic diamond crystals of type IIa implanted with high energy (9-18 MeV) phosphorus ions have been studied by using electron spin resonance (ESR) technique. The intensity and the linewidth of the ESR signal attributed to the dangling bond of the amorphous phase varied with the implantation dose, suggesting the nature of the amorphization varies with the dose. The ESR signals of point defects have been observed in the low dose as-implanted crystals and in the high dose crystals annealed at high temperature and at high pressure. (author)

  19. Trapping of deuterium in krypton-implanted nickel

    International Nuclear Information System (INIS)

    Frank, R.C.; McManus, S.P.; Rehn, L.E.; Baldo, P.

    1986-01-01

    Krypton ions with energy 600 keV were implanted in nickel to fluences of 2 x 10 16 cm -2 under three different conditions. Deuterium was subsequently introduced into the implanted regions by electrolysis at room temperature. After the diffusible deuterium was permitted to escape, the 2 H( 3 He, 1 H) 4 He nuclear reaction was used to analyze for the trapped deuterium during an isochronal annealing program. The region implanted at 100 0 C with no higher temperature anneal had the largest number of traps; the region implanted at 100 0 C and annealed for 100 min at 500 0 C had considerably less; the region implanted at 500 0 C had the least. Electron diffraction patterns confirmed the existence of solid crystalline krypton in all three regions. Transmission electron microscope studies revealed precipitates with an average diameter of 8 nm in the region implanted at 500 0 C. The two regions implanted at 100 0 C contained smaller precipitates. Trap binding enthalpies were obtained by math modeling. In addition to the traps with binding enthalpy of 0.55 eV reported earlier by other investigators for helium implanted in nickel, a smaller number of traps with binding enthalpies up to 0.83 eV were also found. The trapping of deuterium by various types of imperfections, including the solid krypton precipitates, is discussed

  20. Damage related deep electron levels in ion implanted GaAs

    International Nuclear Information System (INIS)

    Allsopp, D.W.E.; Peaker, A.R.

    1986-01-01

    A study has been made of the deep electron levels in semi-insulating GaAs implanted with either 78 Se + or 29 Si + ions and rendered n-type by subsequent annealing without encapsulation in partial pressures of arsenic or arsine. Three implantation related deep states were detected with concentration profiles approximating to the type of Gaussian distributions expected for point defects related to ion implantation damage. Further heat treatment of the samples at 500 0 C in a gas ambient of U 2 /H 2 substantially reduced concentration of these deep levels. Two of these states were thought to be related to displacements of the substrate atoms. The third, at Esubc -0.67 eV, was found in only 78 Se + ion implanted GaAs substrates and was thought to be a defect involving both Se and As atoms, rather than intrinsic lattice disorder. It is proposed that the annealing rate of these implantation related deep levels depends crucially on the in-diffusion of arsenic vacancies during heat treatments. (author)

  1. A radiographic analysis of implant component misfit.

    LENUS (Irish Health Repository)

    Sharkey, Seamus

    2011-07-01

    Radiographs are commonly used to assess the fit of implant components, but there is no clear agreement on the amount of misfit that can be detected by this method. This study investigated the effect of gap size and the relative angle at which a radiograph was taken on the detection of component misfit. Different types of implant connections (internal or external) and radiographic modalities (film or digital) were assessed.

  2. Increased crown-to-implant ratio may not be a risk factor for dental implant failure under appropriate plaque control.

    Science.gov (United States)

    Okada, Shinsuke; Koretake, Katsunori; Miyamoto, Yasunari; Oue, Hiroshi; Akagawa, Yasumasa

    2013-01-01

    The aim of this study was to evaluate whether increased crown-to-implant (C/I) ratio influences implant stability or not under proper healthy control of peri-implant mucosa. The hypothesis of this study is that implant stability can be maintained despite High C/I, under appropriate plaque control. Five male Beagle-Labrador hybrid dogs (2 years old) were used. Their bilateral mandibular premolar extraction was performed. After allowing 12 weeks for bone healing, 3 types of vertical marginal bone loss were simultaneously prepared randomly. Then, 30 titanium implants were placed in the edentulous areas and defined as High C/I, Mid C/I and Low C/I groups. This time point was designated as the baseline (0 Week). Twelve weeks after implant placement, metal superstructures were cemented to the implants and an occlusal plate was set at the opposite side. At the same time, Calcein green was injected for remodeling evaluation. Implants were loaded by feeding the dogs a hard pellet diet. Tooth brushing was performed 5 days per week during the study to maintain healthy peri-implant mucosa. Twenty-four weeks following implant placement, the interface structure was evaluated clinically, radiologically, and histologically. Implant stability quotient (ISQ) increased with time in all 3 groups, without any significant correlation with the C/I value (p >0.05). Moreover, mean marginal bone loss adjacent around implants in all 3 groups ranged between 0.11 and 0.19 mm, with no significant difference (p >0.05). Many fluorescence-labeled bones are shown in the High C/I group. It is considered that high remodeling activity prevent marginal bone loss in the High C/I group and this may provide favorable implant stability under proper plaque control. These findings suggest that increased C/I may not be a risk factor for implant failure if the peri-implant mucosa is kept healthy, as was the case in this animal model.

  3. Increased crown-to-implant ratio may not be a risk factor for dental implant failure under appropriate plaque control.

    Directory of Open Access Journals (Sweden)

    Shinsuke Okada

    Full Text Available OBJECTIVE: The aim of this study was to evaluate whether increased crown-to-implant (C/I ratio influences implant stability or not under proper healthy control of peri-implant mucosa. The hypothesis of this study is that implant stability can be maintained despite High C/I, under appropriate plaque control. MATERIALS AND METHODS: Five male Beagle-Labrador hybrid dogs (2 years old were used. Their bilateral mandibular premolar extraction was performed. After allowing 12 weeks for bone healing, 3 types of vertical marginal bone loss were simultaneously prepared randomly. Then, 30 titanium implants were placed in the edentulous areas and defined as High C/I, Mid C/I and Low C/I groups. This time point was designated as the baseline (0 Week. Twelve weeks after implant placement, metal superstructures were cemented to the implants and an occlusal plate was set at the opposite side. At the same time, Calcein green was injected for remodeling evaluation. Implants were loaded by feeding the dogs a hard pellet diet. Tooth brushing was performed 5 days per week during the study to maintain healthy peri-implant mucosa. Twenty-four weeks following implant placement, the interface structure was evaluated clinically, radiologically, and histologically. RESULT: Implant stability quotient (ISQ increased with time in all 3 groups, without any significant correlation with the C/I value (p >0.05. Moreover, mean marginal bone loss adjacent around implants in all 3 groups ranged between 0.11 and 0.19 mm, with no significant difference (p >0.05. Many fluorescence-labeled bones are shown in the High C/I group. It is considered that high remodeling activity prevent marginal bone loss in the High C/I group and this may provide favorable implant stability under proper plaque control. CONCLUSION: These findings suggest that increased C/I may not be a risk factor for implant failure if the peri-implant mucosa is kept healthy, as was the case in this animal model.

  4. Titanium versus zirconia implants supporting maxillary overdentures: three-dimensional finite element analysis.

    Science.gov (United States)

    Osman, Reham B; Elkhadem, Amr H; Ma, Sunyoung; Swain, Michael V

    2013-01-01

    The purpose of this study was to compare the stress and strain occurring in peri-implant bone and implants used to support maxillary overdentures. Three-dimensional finite element analysis (3D FEA) was used to compare one-piece zirconia and titanium implants. Two types of implants were simulated using a 3D FEA model: one-piece zirconia and titanium implants (diameter, 3.8 × 11.5 mm) with 2.25-mm diameter ball abutments. In each simulation four implants were placed bilaterally in the canine/premolar region of an edentulous maxillary model. Static loads were applied axially and 20 degrees buccolingually on the buccal slope of the lingual cusps of posterior teeth of the first quadrant. Von Mises stresses and equivalent strains generated in peri-implant bone and first principal stresses in the implants were calculated. Comparable stress and strain values were shown in the peri-implant bone for both types of implants. The maximum equivalent strain produced in the peri-implant region was mostly within the range for bone augmentation. Under oblique loading, maximum von Mises stresses and equivalent strain were more evident at the neck of the most distal implant on the loaded side. Under axial load, the stress and strain were transferred to the peri-implant bone around the apex of the implant. Maximum tensile stresses that developed for either material were well below their fracture strength. The highest stresses were mainly located at the distobuccal region of the neck for the two implant materials under both loading conditions. From a biomechanical point of view, ceramic implants made from yttrium-stabilized tetragonal polycrystalline zirconia may be a potential alternative to conventional titanium implants for the support of overdentures. This is particularly relevant for a select group of patients with a proven allergy to titanium. Prospective clinical studies are still required to confirm these in vitro results. Different simulations presenting various cortical bone

  5. Influence of immediate loading on provisional restoration in dental implant stability

    Science.gov (United States)

    Ikbal, M.; Odang, R. W.; Indrasari, M.; Dewi, R. S.

    2017-08-01

    The success of dental implant treatment is determined by the primary stability at placement. One factor that could influence this stability is occlusal loading through provisional restoration. Two types of loading protocols are usually used: immediate and delayed loading. However, some controversies remain about the influence of occlusal loading on implant stability. Therefore, the influence of immediate loading on implant stability must be studied. An animal study was conducted by placing nine dental implants in the mandibular jaw of three Macaca fascicularis. Provisional restorations with various occlusal contacts (no, light, and normal contact) were placed on the implant. The implant stability was measured using the Ostell ISQ three times: immediately (baseline) and at the first and second months after implant placement. The implant stability between implants with no and normal occlusal contact as well as light and normal occlusal contact showed significant differences (p implant placement. However, no significant increase (p > 0.05) in implant stability was seen at the baseline and the first and second months after implant placement for all occlusal contact groups. Immediate loading influenced the implant stability, and provisional restoration of implant without occlusal contact showed the highest implant stability.

  6. Immediate loading of implants in the aesthetic zone: comparison between two placement timings.

    Science.gov (United States)

    Carini, Fabrizio; Longoni, Salvatore; Pisapia, Valeria; Francesconi, Manuel; Saggese, Vito; Porcaro, Gianluca

    2014-01-01

    Implant rehabilitation delivered in accordance with the traditional protocol has proven to be highly predictable and acceptable (1). Nevertheless, the application of immediate loading on post-extraction implants, especially for aesthetic zones, has now considerably increased (2). The aim of this work is to illustrate the immediate loading of implants placed in the aesthetic zone through tapered design fixtures with microgeometry of a high degree of porosity inserted at the same time or 4-8 weeks from dental avulsion (TSA® Advance, Phibo®). A total of 15 implant fixtures of which 8 at an interval of 4-8 weeks from extraction (type 2) and the remaining according to the immediate post-extraction technique (type 1) were positioned. All implants were prosthesized within 24 hours from the placement. Definitive crowns replaced provisional restorations after 20-24 weeks. After 4 and 12 months from implant insertion, the following parameters were assessed: X-ray image, pain, mobility or suppuration, soft tissue condition and aesthetic appearance. Percentage of osseointegration was 93.75%, and 53.5% of the osseointegrated fixtures was type 2. No statistically significant difference between the mean ISQ values for implants of type 1 and 2 both in the post-operative period and after 12 months was evident, indicating that the timing of insertion did not affect the achievement of stability for the implant fixtures tested in our study. Immediate post-extraction implants showed a greater propensity for gingival recession and a peri-implant radiolucency greater than those placed at an interval of 4-8 weeks. The values obtained for the PES/WES and the subjective evaluation of the analyzed sample showed the considerable aesthetic value and the high level of satisfaction guaranteed by the implant technique illustrated. Although well-designed, high quality, randomized clinical trials are still needed as well as the requirement to establish a common, complete, and reproducible index

  7. Short dental implants: an emerging concept in implant treatment.

    Science.gov (United States)

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  8. Digital photoelastic analysis applied to implant dentistry

    Science.gov (United States)

    Ramesh, K.; Hariprasad, M. P.; Bhuvanewari, S.

    2016-12-01

    Development of improved designs of implant systems in dentistry have necessitated the study of stress fields in the implant regions of the mandible/maxilla for better understanding of the biomechanics involved. Photoelasticity has been used for various studies related to dental implants in view of whole field visualization of maximum shear stress in the form of isochromatic contours. The potential of digital photoelasticity has not been fully exploited in the field of implant dentistry. In this paper, the fringe field in the vicinity of the connected implants (All-On-Four® concept) is analyzed using recent advances in digital photoelasticity. Initially, a novel 3-D photoelastic model making procedure, to closely mimic all the anatomical features of the human mandible is proposed. By choosing appropriate orientation of the model with respect to the light path, the essential region of interest were sought to be analysed while keeping the model under live loading conditions. Need for a sophisticated software module to carefully identify the model domain has been brought out. For data extraction, five-step method is used and isochromatics are evaluated by twelve fringe photoelasticity. In addition to the isochromatic fringe field, whole field isoclinic data is also obtained for the first time in implant dentistry, which could throw important information in improving the structural stability of the implant systems. Analysis is carried out for the implant in the molar as well as the incisor region. In addition, the interaction effects of loaded molar implant on the incisor area are also studied.

  9. A direct plasma injection system into an RFQ for clean and safe ion implantation

    International Nuclear Information System (INIS)

    Takeuchi, T.; Katayama, T.; Okamura, M.; Yano, K.; Sakumi, A.; Hattori, T.; Hayashizaki, N.; Jameson, R.A.

    2002-01-01

    A new injection system, direct plasma injection system, was tested and its principle was proved successfully. We found that one of advantages of this injection system was efficient consumption of source materials. Large portions of induced ions can be injected into a first stage accelerator. This feature is quite useful for ion implantation applications, because toxic exhaust gas can be eliminated. In order to utilize this system for industrial application, the feasibility of a boron injection scheme using a Nd:YAG laser system was investigated

  10. Efficacies of 125I seed implantation in advanced stage central lung cancer via fibrobronchoscope

    International Nuclear Information System (INIS)

    Liu Jianguo; An Liqing; Cheng Jinguang; Zhang Yufen; Guo Xiaokui

    2009-01-01

    Objective: To explore the temporal curative effect of 125 I seed implantation in advanced stage central type lung cancer. Methods: 125 I seed was implanted in 56 patients confirmed advanced stage central type lung cancer via fibrobronchoscope and all cases were fellow up in certain duration to explore their efficacies and the adverse reaction. Results: Total efficient rate was 76.78% in 56 patients. Lung reexpanded rate was 90.90%. Conclusion: The therapy of 125 I seed implantation in advanced stage central type lung cancer is safe and available. (authors)

  11. Primary stability of a hybrid self-tapping implant compared to a cylindrical non-self-tapping implant with respect to drilling protocols in an ex vivo model.

    Science.gov (United States)

    Toyoshima, Takeshi; Wagner, Wilfried; Klein, Marcus Oliver; Stender, Elmar; Wieland, Marco; Al-Nawas, Bilal

    2011-03-01

    Modifications of implant design have been intending to improve primary stability. However, little is known about investigation of a hybrid self-tapping implant on primary stability. The aims of this study were to evaluate the primary stability of two hybrid self-tapping implants compared to one cylindrical non-self-tapping implant, and to elucidate the relevance of drilling protocols on primary stability in an ex vivo model. Two types of hybrid self-tapping implants (Straumann® Bone Level implant [BL], Straumann® Tapered Effect implant [TE]) and one type of cylindrical non-self-tapping implant (Straumann® Standard Plus implant [SP]) were investigated in the study. In porcine iliac cancellous bones, 10 implants each were inserted either using standard drilling or under-dimensioned drilling protocol. The evaluation of implant-bone interface stability was carried out by records of maximum insertion torque, the Periotest® (Siemens, Bensheim, Germany), the resonance frequency analysis (RFA), and the push-out test. In each drilling group, the maximum insertion torque values of BL and TE were significantly higher than SP (p=.014 and p=.047, respectively). In each group, the Periotest values of TE were significantly lower than SP (p=.036 and p=.033, respectively). The Periotest values of BL and TE were significantly lower in the group of under-dimensioned drilling than standard drilling (p=.002 and p=.02, respectively). In the RFA, no statistical significances were found in implants between two groups and between implants in each group. In each group, the push-out values of BL and TE were significantly higher than SP (p=.006 and p=.049, respectively). Hybrid self-tapping implants could achieve a high primary stability which predicts them for use in low-density bone. However, there is still a debate to clarify the influence of under-dimensioned drilling on primary stability. © 2009, Copyright the Authors. Journal Compilation © 2011, Wiley Periodicals, Inc.

  12. Comparison of electrical performances of two n-in-p detectors with different implant type of guard ring by TCAD simulation

    Science.gov (United States)

    Mekheldi, Mohammed; Oussalah, Slimane; Lounis, Abdenour; Brihi, Nourredine

    This paper presents a preliminary comparative study for two different guard rings structures in the purpose of evaluating their electrical performances. The two structures are based on the n-in-p technology with different implant type of guard rings. I-V characteristics have been simulated using Silvaco/ATLAS software for both structures and compared for various parameters of substrate, guard ring and oxide. Simulation results show that the shape of leakage current is almost the same in all simulations but in terms of breakdown voltage, n-in-p structure with n-type guard rings ensures high voltage stability.

  13. Cochlear Implantation in Patients With Usher Syndrome Type IIa Increases Performance and Quality of Life.

    Science.gov (United States)

    Hartel, Bas P; van Nierop, Josephine W I; Huinck, Wendy J; Rotteveel, Liselotte J C; Mylanus, Emmanuel A M; Snik, Ad F; Kunst, Henricus P M; Pennings, Ronald J E

    2017-07-01

    Usher syndrome type IIa (USH2a) is characterized by congenital moderate to severe hearing impairment and retinitis pigmentosa. Hearing rehabilitation starts in early childhood with the application of hearing aids. In some patients with USH2a, severe progression of hearing impairment leads to insufficient speech intelligibility with hearing aids and issues with adequate communication and safety. Cochlear implantation (CI) is the next step in rehabilitation of such patients. This study evaluates the performance and benefit of CI in patients with USH2a. Retrospective case-control study to evaluate the performance and benefit of CI in 16 postlingually deaf adults (eight patients with USH2a and eight matched controls). Performance and benefit were evaluated by a speech intelligibility test and three quality-of-life questionnaires. Patients with USH2a with a mean age of 59 years at implantation exhibited good performance after CI. The phoneme scores improved significantly from 41 to 87% in patients with USH2a (p = 0.02) and from 30 to 86% in the control group (p = 0.001). The results of the questionnaire survey demonstrated a clear benefit from CI. There were no differences in performance or benefit between patients with USH2a and control patients before and after CI. CI increases speech intelligibility and improves quality of life in patients with USH2a.

  14. Magnet-Retained Two-Mini-Implant Overdenture: Clinical and Mechanical Consideration

    Directory of Open Access Journals (Sweden)

    Yuichi Ishida

    2016-10-01

    Full Text Available Two-implant overdentures have become the accepted treatment for restoring mandibular edentulism. The dimensions of regular implants sometimes limit their use, such as in the case of narrow ridges. Mini-implants with reduced diameters (less than 3.0 mm enable insertion into narrow ridges. A magnet-retained two-mini-implant overdenture system was developed and is described in this paper. Additionally, we describe a clinical mandibular procedure using the system and evaluate its biomechanical performance.

  15. Bone Response to Two Dental Implants with Different Sandblasted/Acid-Etched Implant Surfaces: A Histological and Histomorphometrical Study in Rabbits

    Directory of Open Access Journals (Sweden)

    Antonio Scarano

    2017-01-01

    Full Text Available Background. Scientific evidence in the field of implant dentistry of the past 20 years established that titanium rough surfaces have shown improved osseointegration rates. In a majority of dental implants, the surface microroughness was obtained by grit blasting and/or acid etching. The aim of the study was to evaluate in vivo two different highly hydrophilic surfaces at different experimental times. Methods. Calcium-modified (CA and SLActive surfaces were evaluated and a total of 18 implants for each type of surface were positioned into the rabbit articular femoral knee-joint in a split model experiment, and they were evaluated histologically and histomorphometrically at 15, 30, and 60 days of healing. Results. Bone-implant contact (BIC at the two-implant surfaces was significantly different in favor of the CA surface at 15 days (p=0.027, while SLActive displayed not significantly higher values at 30 (p=0.51 and 60 days (p=0.061. Conclusion. Both implant surfaces show an intimate interaction with newly formed bone.

  16. Pacemaker, implanted cardiac defibrillator and irradiation: Management proposal in 2010 depending on the type of cardiac stimulator and prognosis and location of cancer

    International Nuclear Information System (INIS)

    Lambert, P.; Da Costa, A.; Marcy, P.Y.; Kreps, S.; Angellier, G.; Marcie, S.; Bondiau, P.Y.; Briand-Amoros, C.; Thariat, J.

    2011-01-01

    Ionizing radiation may interfere with electric components of pacemakers or implantable cardioverter defibrillators. The type, severity and extent of radiation damage to pacemakers, have previously been shown to depend on the total dose and dose rate. Over 300,000 new cancer cases are treated yearly in France, among which 60% are irradiated in the course of their disease. One among 400 of these patients has an implanted pacemaker or defibrillator. The incidence of pacemaker and implanted cardioverter defibrillator increases in an ageing population. The oncologic prognosis must be weighted against the cardiologic prognosis in a multidisciplinary and transversal setting. Innovative irradiation techniques and technological sophistications of pacemakers and implantable cardioverter-defibrillators (with the introduction of more radiosensitive complementary metal-oxide-semiconductors since 1970) have potentially changed the tolerance profiles. This review of the literature studied the geometric, dosimetric and radiobiological characteristics of the radiation beams for high energy photons, stereotactic irradiation, proton-therapy. Standardized protocols and radiotherapy optimization (particle, treatment fields, energy) are advisable in order to improve patient management during radiotherapy and prolonged monitoring is necessary following radiation therapy. The dose received at the pacemaker/heart should be calculated. The threshold for the cumulated dose to the pacemaker/implantable cardioverter-defibrillator (2 to 5 Gy depending on the brand), the necessity to remove/displace the device based on the dose-volume histogram on dosimetry, as well as the use of lead shielding and magnet are discussed. (authors)

  17. Quantification of ion or atom transfer phenomena in materials implanted by nuclear methods

    International Nuclear Information System (INIS)

    Oudadesse, Hassane

    1998-01-01

    Knowledge of transfer of the constituents of a system from regions of higher to lower concentration is of interest for implanted bio-materials. It allows determining the rate at which this material is integrated in a living material. To evaluate the ossification kinetics and to study the bio-functionality in corals of Ca and Sr, irradiations with a 10 13 n.cm -2 .s -1 was performed, followed by the examination of changes in the localization of these elements. By using PIXE analysis method the distribution of Ca, P, Sr, Zn and Fe in the implant, bone and bone-implant interfaces were determined. Thus, it was shown that resorption of coral in sheep is achieved in 5 months after implantation and is identical to the cortical tissues 4 months after implantation in animals as for instance in hares. We have analyzed the tissues from around the prostheses extracted from patients. The samples were calcined and reduced to powder weighting some milligrams. We have adopted for this study the PIXE analysis method. The samples were irradiated by a proton beam of 3 MeV and about 400 μm diameter. The results show the presence of the elements Ti, Fe, Cr, Ni or Zn according to the type of the implanted prosthesis. This dispersal of the metallic ions and atoms contaminate the tissues. The transfer factors translate the exchanges between bone and the implanted material. The solvatation phenomenon and the electric charge equilibrium explain the transfer order of cations Mg 2+ , Ca 2+ and Sr 2+ and of the anion PO 4 3- . We have also determined these factors for the elements Ti, Cr and Ni. An original technique to study the bone bio-functionality was used. Use of phosphate derivatives labelled by 99m Tc allows obtaining information about the fixation of radioactive tracer. It was found that only after the eighth month at the implantation the neo-formed bone fixes the MDP (methyl diphosphate) labelled by 99m Tc in a similar way as in the control sample. Starting from this moment the

  18. Wireless Power Transfer Strategies for Implantable Bioelectronics.

    Science.gov (United States)

    Agarwal, Kush; Jegadeesan, Rangarajan; Guo, Yong-Xin; Thakor, Nitish V

    2017-01-01

    Neural implants have emerged over the last decade as highly effective solutions for the treatment of dysfunctions and disorders of the nervous system. These implants establish a direct, often bidirectional, interface to the nervous system, both sensing neural signals and providing therapeutic treatments. As a result of the technological progress and successful clinical demonstrations, completely implantable solutions have become a reality and are now commercially available for the treatment of various functional disorders. Central to this development is the wireless power transfer (WPT) that has enabled implantable medical devices (IMDs) to function for extended durations in mobile subjects. In this review, we present the theory, link design, and challenges, along with their probable solutions for the traditional near-field resonant inductively coupled WPT, capacitively coupled short-ranged WPT, and more recently developed ultrasonic, mid-field, and far-field coupled WPT technologies for implantable applications. A comparison of various power transfer methods based on their power budgets and WPT range follows. Power requirements of specific implants like cochlear, retinal, cortical, and peripheral are also considered and currently available IMD solutions are discussed. Patient's safety concerns with respect to electrical, biological, physical, electromagnetic interference, and cyber security from an implanted neurotech device are also explored in this review. Finally, we discuss and anticipate future developments that will enhance the capabilities of current-day wirelessly powered implants and make them more efficient and integrable with other electronic components in IMDs.

  19. A wireless transmission system powered by an enzyme biofuel cell implanted in an orange.

    Science.gov (United States)

    MacVittie, Kevin; Conlon, Tyler; Katz, Evgeny

    2015-12-01

    A biofuel cell composed of catalytic electrodes made of "buckypaper" modified with PQQ-dependent glucose dehydrogenase and FAD-dependent fructose dehydrogenase on the anode and with laccase on the cathode was used to activate a wireless information transmission system. The cathode/anode pair was implanted in orange pulp extracting power from its content (glucose and fructose in the juice). The open circuit voltage, Voc, short circuit current density, jsc, and maximum power produced by the biofuel cell, Pmax, were found as ca. 0.6 V, ca. 0.33 mA·cm(-2) and 670 μW, respectively. The voltage produced by the biofuel cell was amplified with an energy harvesting circuit and applied to a wireless transmitter. The present study continues the research line where different implantable biofuel cells are used for the activation of electronic devices. The study emphasizes the biosensor and environmental monitoring applications of implantable biofuel cells harvesting power from natural sources, rather than their biomedical use. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Implant isolation of plasma-assisted MBE grown GaInAsN for opto-telecommunication applications

    International Nuclear Information System (INIS)

    Ahmed, S.; Lin, J.; Haq, A.; Sealy, B.

    2005-01-01

    The material system GaInAsN is considered to be one of the key materials for next generation telecommunication applications providing high data transmission and lower power consumption. The strong dependence of the band gap on the nitrogen content has made this material important for a variety of applications. We report on the effects of ion implantation on the achieved electrical isolation in GaInAsN layers. GaInAsN was grown using either a direct nitrogen beam or dispersive nitrogen radicals by a RF activated nitrogen source. Proton and iron implants were performed at RT and 77 K, respectively in order to effectively isolate the as-grown silicon (n-type) GaInAsN layers. Results show that the sheet resistance of n-type layers can be increased by about four and five orders of magnitude by proton and iron implantation, respectively. The study of annealing temperature dependence of sheet resistivity in proton-isolated samples shows that the electrical isolation can be preserved up to 450 deg. C. The thermally stable high resistivity region persists up to 600 deg. C when the implantation is performed with iron at 77 K. These results are novel and have ramifications for device engineers