WorldWideScience

Sample records for type dielectrophoretic device

  1. Dielectrophoretic Microfluidic Device for in Vitro Fertilization

    Directory of Open Access Journals (Sweden)

    Hong-Yuan Huang

    2018-03-01

    Full Text Available The aim of this work was to create a microfluidic platform that uses in vitro fertilization (IVF and avoids unnecessary damage to oocytes due to the dielectrophoretic force manipulation of the sperms and oocytes that occurs in a traditional IVF operation. The device from this research can serve also to decrease medium volumes, as well as the cost of cell culture under evaporation, and to prevent unnecessary risk in intracytoplasmic sperm injection (ICSI. To decrease the impact and destruction of the oocyte and the sperm, we adopted a positive dielectrophoretic force to manipulate both the sperms and the oocyte. The mouse oocytes were trapped with a positive dielectrophoretic (p-DEP force by using Indium Tin Oxide (ITO-glass electrodes; the ITO-glass electrode chip was fabricated by wet etching the ITO-glass. The polydimethylsiloxane (PDMS flow-focusing microfluidic device was used to generate microdroplets of micrometer size to contain the zygotes. The volume of the microdroplets was controlled by adjusting the flow rates of both inlets for oil and the DEP buffer. As a result, the rate of fertilization was increased by about 5% beyond that of the DEP treatment in traditional IVF, and more than 20% developed to the blastocyst stage with a low sperm-oocyte ratio.

  2. Dielectrophoretic assembly of carbon nanotube devices

    DEFF Research Database (Denmark)

    Dimaki, Maria

    The purpose of this project has been to assemble single-walled carbon nanotubes on electrodes at the tip of a biocompatible cantilever and use these for chemical species sensing in air and liquid, for example in order to measure the local activity from ion channels in the cell membrane....... The electrical resistance of carbon nanotubes has been shown to be extremely sensitive to gas molecules. Dielectrophoresis is a method capable of quickly attracting nanotubes on microelectrodes by using an electric field, thus enabling nanotube integration in microsystems. Dielectrophoresis offers also....... A model for the dielectrophoretic assembly of carbon nanotubes on microelectrodes was developed and several simulations were conducted using values from the available literature for the various key parameters. The model can give qualitative results regarding the parameters dominating the dielectrophoretic...

  3. Dielectrophoretic trapping of DNA-coated gold nanoparticles on silicon based vertical nanogap devices.

    Science.gov (United States)

    Strobel, Sebastian; Sperling, Ralph A; Fenk, Bernhard; Parak, Wolfgang J; Tornow, Marc

    2011-06-07

    We report on the successful dielectrophoretic trapping and electrical characterization of DNA-coated gold nanoparticles on vertical nanogap devices (VNDs). The nanogap devices with an electrode distance of 13 nm were fabricated from Silicon-on-Insulator (SOI) material using a combination of anisotropic reactive ion etching (RIE), selective wet chemical etching and metal thin-film deposition. Au nanoparticles (diameter 40 nm) coated with a monolayer of dithiolated 8 base pairs double stranded DNA were dielectrophoretically trapped into the nanogap from electrolyte buffer solution at MHz frequencies as verified by scanning and transmission electron microscopy (SEM/TEM) analysis. First electrical transport measurements through the formed DNA-Au-DNA junctions partially revealed an approximately linear current-voltage characteristic with resistance in the range of 2-4 GΩ when measured in solution. Our findings point to the importance of strong covalent bonding to the electrodes in order to observe DNA conductance, both in solution and in the dry state. We propose our setup for novel applications in biosensing, addressing the direct interaction of biomolecular species with DNA in aqueous electrolyte media.

  4. Analytical Formulation of the Electric Field Induced by Electrode Arrays: Towards Automated Dielectrophoretic Cell Sorting

    Directory of Open Access Journals (Sweden)

    Vladimir Gauthier

    2017-08-01

    Full Text Available Dielectrophoresis is defined as the motion of an electrically polarisable particle in a non-uniform electric field. Current dielectrophoretic devices enabling sorting of cells are mostly controlled in open-loop applying a predefined voltage on micro-electrodes. Closed-loop control of these devices would enable to get advanced functionalities and also more robust behavior. Currently, the numerical models of dielectrophoretic force are too complex to be used in real-time closed-loop control. The aim of this paper is to propose a new type of models usable in this framework. We propose an analytical model of the electric field based on Fourier series to compute the dielectrophoretic force produced by parallel electrode arrays. Indeed, this method provides an analytical expression of the electric potential which decouples the geometrical factors (parameter of our system, the voltages applied on electrodes (input of our system, and the position of the cells (output of our system. Considering the Newton laws on each cell, it enables to generate easily a dynamic model of the cell positions (output function of the voltages on electrodes (input. This dynamic model of our system is required to design the future closed-loop control law. The predicted dielectrophoretic forces are compared to a numerical simulation based on finite element model using COMSOL software. The model presented in this paper enables to compute the dielectrophoretic force applied to a cell by an electrode array in a few tenths of milliseconds. This model could be consequently used in future works for closed-loop control of dielectrophoretic devices.

  5. Analysis of the role of elution buffers on the separation capabilities of dielectrophoretic devices

    Directory of Open Access Journals (Sweden)

    Rossana Di Martino

    2016-03-01

    Full Text Available Field flow fractionation dielectrophoretic (FFF-DEP devices are currently used, among the others, for the separation of tumor cells from healthy blood cells. To this end specific suspension/elution buffers (EBs, with reduced conductivity (with respect to that of the cell cytoplasm are generally used. In this paper we investigate the long-term alterations of the cells and elution buffers. We find that the EB conductivity is critically modified within few minutes after cells suspension. In turn, this modification results in a change the ideal separation frequency of the FFF-DEP device. On the other hand we prove that DEP manipulation is preserved for more than three hours for cells suspended in the considered EBs. Keywords: Dielectrophoresis, Elution buffer, Circulating tumor cells, Cell motility

  6. Self assembly of organic nanostructures and dielectrophoretic assembly of inorganic nanowires.

    Science.gov (United States)

    Dholakia, Geetha; Kuo, Steven; Allen, E. L.

    2007-03-01

    Self assembly techniques enable the organization of organic molecules into nanostructures. Currently engineering strategies for efficient assembly and routine integration of inorganic nanoscale objects into functional devices is very limited. AC Dielectrophoresis is an efficient technique to manipulate inorganic nanomaterials into higher dimensional structures. We used an alumina template based sol-gel synthesis method for the growth of various metal oxide nanowires with typical diameters of 100-150 nm, ranging in length from 3-10 μm. Here we report the dielectrophoretic assembly of TiO2 nanowires, an important material for photocatalysis and photovoltaics, onto interdigitated devices. Self assembly in organic nanostructures and its dependence on structure and stereochemistry of the molecule and dielectrophoretic field dependence in the assembly of inorganic nanowires will be compared and contrasted. Tunneling spectroscopy and DOS of these nanoscale systems will also be discussed.

  7. Continuous particle separation in a serpentine microchannel via negative and positive dielectrophoretic focusing

    International Nuclear Information System (INIS)

    Church, Christopher; Zhu, Junjie; Nieto, Juan; Keten, Gyunay; Ibarra, Erl; Xuan, Xiangchun

    2010-01-01

    Dielectrophoresis (DEP) has been widely used to focus and separate cells and particles in microfluidic devices. This work first demonstrates negative and positive dielectrophoretic focusing of particles in a serpentine microchannel by changing only the electric conductivity of the suspending fluid. Due to the channel turn-induced dielectrophoretic force, particles are focused to either the centerline or the sidewalls of the channel when their electric conductivity is lower (i.e. negative DEP) or higher (i.e. positive DEP) than that of the fluid. These distinctive dielectrophoretic focusing phenomena in a serpentine microchannel are then combined to implement a continuous separation between particles of different sizes and electric conductivities. Such separation eliminates the fabrication of in-channel microelectrodes or micro-insulators that are typically required in DEP-based separation techniques. A numerical model is also developed to predict the particle motion, and the simulation results agree reasonably with the observed particle focusing and separation behaviors.

  8. Dielectrophoretic self-assembly of polarized light emitting poly(9,9-dioctylfluorene) nanofibre arrays

    International Nuclear Information System (INIS)

    O'Riordan, A; Iacopino, D; Lovera, P; Floyd, L; Reynolds, K; Redmond, G

    2011-01-01

    Conjugated polymer based 1D nanostructures are attractive building blocks for future opto-electronic nanoscale devices and systems. However, a critical challenge remains the lack of manipulation methods that enable controlled and reliable positioning and orientation of organic nanostructures in a fast, reliable and scalable manner. To address this challenge, we explore dielectrophoretic assembly of discrete poly(9,9-dioctylfluorene) nanofibres and demonstrate site selective assembly and orientation of these fibres. Nanofibre arrays were assembled preferentially at receptor electrode edges, being aligned parallel to the applied electric field with a high order parameter fit (∼0.9) and exhibiting an emission dichroic ratio of ∼ 4.0. As such, the dielectrophoretic method represents a fast, reliable and scalable self-assembly approach for manipulation of 1D organic nanostructures. The ability to fabricate nanofibre arrays in this manner could be potentially important for exploration and development of future nanoscale opto-electronic devices and systems.

  9. Dielectrophoretic capture of low abundance cell population using thick electrodes

    OpenAIRE

    Marchalot, Julien; Chateaux, Jean-François; Faivre, Magalie; Mertani, Hichem C.; Ferrigno, Rosaria; Deman, Anne-Laure

    2015-01-01

    Enrichment of rare cell populations such as Circulating Tumor Cells (CTCs) is a critical step before performing analysis. This paper presents a polymeric microfluidic device with integrated thick Carbon-PolyDimethylSiloxane composite (C-PDMS) electrodes designed to carry out dielectrophoretic (DEP) trapping of low abundance biological cells. Such conductive composite material presents advantages over metallic structures. Indeed, as it combines properties of both the matrix and doping particle...

  10. Polymer cantilever platform for dielectrophoretic assembly of carbon nanotubes

    DEFF Research Database (Denmark)

    Johansson, Alicia; Calleja, M.; Dimaki, Maria

    2004-01-01

    A polymer cantilever platform for dielectrophoretic assembly of carbon nanotubes has been designed and realized. Multi-walled carbon nanotubes from aqueous solution have been assembled between two metal electrodes that are separated by 2 mu m and embedded in the polymer cantilever. The entire chip......, except for the metallic electrodes and wiring, was fabricated in the photoresist SU-8. SU-8 allows for an inexpensive, flexible and fast fabrication method, and the cantilever platform provides a hydrophobic surface that should be well suited for nanotube assembly. The device can be integrated in a micro...

  11. Dielectrophoresis and dielectrophoretic impedance detection of adenovirus and rotavirus

    Science.gov (United States)

    Nakano, Michihiko; Ding, Zhenhao; Suehiro, Junya

    2016-01-01

    The aim of this study is the electrical detection of pathogenic viruses, namely, adenovirus and rotavirus, using dielectrophoretic impedance measurement (DEPIM). DEPIM consists of two simultaneous processes: dielectrophoretic trapping of the target and measurement of the impedance change and increase in conductance with the number of trapped targets. This is the first study of applying DEPIM, which was originally developed to detect bacteria suspended in aqueous solutions, to virus detection. The dielectric properties of the viruses were also investigated in terms of their dielectrophoretic behavior. Although their estimated dielectric properties were different from those of bacteria, the trapped viruses increased the conductance of the microelectrode in a manner similar to that in bacteria detection. We demonstrated the electrical detection of viruses within 60 s at concentrations as low as 70 ng/ml for adenovirus and 50 ng/ml for rotavirus.

  12. Impedance technique for measuring dielectrophoretic collection of microbiological particles

    CERN Document Server

    Allsopp, D W E; Brown, A P; Betts, W B

    1999-01-01

    Measurement of the impedance change resulting from the collection of microbiological particles at coplanar electrodes is shown to be an effective and potentially quantitative method of detecting dielectrophoresis. Strong correlations between the frequency-dependent dielectrophoretic collection characteristics measured by impedance change and those observed using an established counting method based on image analysis have been obtained for Escherichia coli. In addition it is shown that the new electrical method can be used to sense dielectrophoretic collection of 19 nm diameter latex beads, particles too small to be resolved by conventional optical detection systems. (author)

  13. Dielectrophoretic Manipulation and Separation of Microparticles Using Microarray Dot Electrodes

    Directory of Open Access Journals (Sweden)

    Bashar Yafouz

    2014-04-01

    Full Text Available This paper introduces a dielectrophoretic system for the manipulation and separation of microparticles. The system is composed of five layers and utilizes microarray dot electrodes. We validated our system by conducting size-dependent manipulation and separation experiments on 1, 5 and 15 μm polystyrene particles. Our findings confirm the capability of the proposed device to rapidly and efficiently manipulate and separate microparticles of various dimensions, utilizing positive and negative dielectrophoresis (DEP effects. Larger size particles were repelled and concentrated in the center of the dot by negative DEP, while the smaller sizes were attracted and collected by the edge of the dot by positive DEP.

  14. Dielectrophoretic separation of gaseous isotopes

    International Nuclear Information System (INIS)

    McConnell, D.B.

    1975-01-01

    Gaseous isotopes are separated from a mixture in a vertically elongated chamber by subjecting the mixture to a nonuniform transverse electric field. Dielectrophoretic separation of the isotopes is effected, producing a transverse temperature gradient in the chamber, thereby enhancing the separation by convective countercurrent flow. In the example given, the process and apparatus are applied to the production of heavy water from steam

  15. Dielectrophoretic capture of low abundance cell population using thick electrodes.

    Science.gov (United States)

    Marchalot, Julien; Chateaux, Jean-François; Faivre, Magalie; Mertani, Hichem C; Ferrigno, Rosaria; Deman, Anne-Laure

    2015-09-01

    Enrichment of rare cell populations such as Circulating Tumor Cells (CTCs) is a critical step before performing analysis. This paper presents a polymeric microfluidic device with integrated thick Carbon-PolyDimethylSiloxane composite (C-PDMS) electrodes designed to carry out dielectrophoretic (DEP) trapping of low abundance biological cells. Such conductive composite material presents advantages over metallic structures. Indeed, as it combines properties of both the matrix and doping particles, C-PDMS allows the easy and fast integration of conductive microstructures using a soft-lithography approach while preserving O2 plasma bonding properties of PDMS substrate and avoiding a cumbersome alignment procedure. Here, we first performed numerical simulations to demonstrate the advantage of such thick C-PDMS electrodes over a coplanar electrode configuration. It is well established that dielectrophoretic force ([Formula: see text]) decreases quickly as the distance from the electrode surface increases resulting in coplanar configuration to a low trapping efficiency at high flow rate. Here, we showed quantitatively that by using electrodes as thick as a microchannel height, it is possible to extend the DEP force influence in the whole volume of the channel compared to coplanar electrode configuration and maintaining high trapping efficiency while increasing the throughput. This model was then used to numerically optimize a thick C-PDMS electrode configuration in terms of trapping efficiency. Then, optimized microfluidic configurations were fabricated and tested at various flow rates for the trapping of MDA-MB-231 breast cancer cell line. We reached trapping efficiencies of 97% at 20 μl/h and 78.7% at 80 μl/h, for 100 μm thick electrodes. Finally, we applied our device to the separation and localized trapping of CTCs (MDA-MB-231) from a red blood cells sample (concentration ratio of 1:10).

  16. A 3-D Microelectrode System for Dielectrophoretic Manipulation of Microparticles

    International Nuclear Information System (INIS)

    Chen, D F; Du, H; Gong, H Q; Li, W H

    2006-01-01

    This paper presents a microfluidic system for manipulation and separation of micron-sized particles based on the combined use of negative dielectrophoresis (DEP) and hydrodynamic forces. A 3-D microelectrode structure (so called paired electrode array) are constructed face to face on the top and bottom sides of the microchannel and driven with highfrequency AC voltage to generate dielectrophoretic gates. Depending on the relative strengths of the two forces, particles such as polystyrene beads or cells carrying by a laminar flow can either penetrate the gate or settle there. This gives rise to certain applications including selectively concentrating particles from the flow, separating particles depending on their sizes or dielectric properties, and automatically positioning particles to selective locations. For this purpose, a microfluidic device consisting of the paired electrode array sitting on the channel has been fabricated using microfabrication techniques. Polystyrene beads were used to study the performance of the device. Experimental results including the concentration and separation of particles are presented

  17. "Artificial micro organs"--a microfluidic device for dielectrophoretic assembly of liver sinusoids.

    Science.gov (United States)

    Schütte, Julia; Hagmeyer, Britta; Holzner, Felix; Kubon, Massimo; Werner, Simon; Freudigmann, Christian; Benz, Karin; Böttger, Jan; Gebhardt, Rolf; Becker, Holger; Stelzle, Martin

    2011-06-01

    In order to study possible toxic side effects of potential drug compounds in vitro a reliable test system is needed. Predicting liver toxicity presents a major challenge of particular importance as liver cells grown in a cell culture suffer from a rapid loss of their liver specific functions. Therefore we are developing a new microfluidic test system for liver toxicity. This test system is based on an organ-like liver 3D co-culture of hepatocytes and endothelial cells. We devised a microfluidic chip featuring cell culture chambers with integrated electrodes for the assembly of liver sinusoids by dielectrophoresis. Fluid channels enable an organ-like perfusion with culture media and test compounds. Different chamber designs were studied and optimized with regard to dielectrophoretic force distribution, hydrodynamic flow profile, and cell trapping rate using numeric simulations. Based on simulation results a microchip was injection-moulded from COP. This chip allowed the assembly of viable hepatocytes and endothelial cells in a sinusoid-like fashion.

  18. Dielectrophoretic sample preparation for environmental monitoring of microorganisms: Soil particle removal.

    Science.gov (United States)

    Fatoyinbo, Henry O; McDonnell, Martin C; Hughes, Michael P

    2014-07-01

    Detection of pathogens from environmental samples is often hampered by sensors interacting with environmental particles such as soot, pollen, or environmental dust such as soil or clay. These particles may be of similar size to the target bacterium, preventing removal by filtration, but may non-specifically bind to sensor surfaces, fouling them and causing artefactual results. In this paper, we report the selective manipulation of soil particles using an AC electrokinetic microfluidic system. Four heterogeneous soil samples (smectic clay, kaolinitic clay, peaty loam, and sandy loam) were characterised using dielectrophoresis to identify the electrical difference to a target organism. A flow-cell device was then constructed to evaluate dielectrophoretic separation of bacteria and clay in a continous flow through mode. The average separation efficiency of the system across all soil types was found to be 68.7% with a maximal separation efficiency for kaolinitic clay at 87.6%. This represents the first attempt to separate soil particles from bacteria using dielectrophoresis and indicate that the technique shows significant promise; with appropriate system optimisation, we believe that this preliminary study represents an opportunity to develop a simple yet highly effective sample processing system.

  19. Polarizability of Six-Helix Bundle and Triangle DNA Origami and Their Escape Characteristics from a Dielectrophoretic Trap.

    Science.gov (United States)

    Gan, Lin; Camacho-Alanis, Fernanda; Ros, Alexandra

    2015-12-15

    DNA nanoassemblies, such as DNA origamis, hold promise in biosensing, drug delivery, nanoelectronic circuits, and biological computing, which require suitable methods for migration and precision positioning. Insulator-based dielectrophoresis (iDEP) has been demonstrated as a powerful migration and trapping tool for μm- and nm-sized colloids as well as DNA origamis. However, little is known about the polarizability of origami species, which is responsible for their dielectrophoretic migration. Here, we report the experimentally determined polarizabilities of the six-helix bundle origami (6HxB) and triangle origami by measuring the migration times through a potential landscape exhibiting dielectrophoretic barriers. The resulting migration times correlate to the depth of the dielectrophoretic potential barrier and the escape characteristics of the origami according to an adapted Kramer's rate model, allowing their polarizabilities to be determined. We found that the 6HxB polarizability is larger than that of the triangle origami, which correlates with the variations in charge density of both origamis. Further, we discuss the orientation of both origami species in the dielectrophoretic trap and discuss the influence of diffusion during the escape process. Our study provides detailed insight into the factors contributing to the migration through dielectrophoretic potential landscapes, which can be exploited for applications with DNA and other nanoassemblies based on dielectrophoresis.

  20. Viability of dielectrophoretically trapped neuronal cortical cells in culture

    NARCIS (Netherlands)

    Heida, Tjitske; Vulto, P; Rutten, Wim; Marani, Enrico

    2001-01-01

    Negative dielectrophoretic trapping of neural cells is an efficient way to position neural cells on the electrode sites of planar micro-electrode arrays. The preservation of viability of the neural cells is essential for this approach. This study investigates the viability of postnatal cortical rat

  1. Direct current dielectrophoretic manipulation of the ionic liquid droplets in water.

    Science.gov (United States)

    Zhao, Kai; Li, Dongqing

    2018-07-13

    The ionic liquids (ILs) as the environmentally benign solvents show great potentials in microemulsion carrier systems and have been widely used in the biochemical and pharmaceutical fields. In the work, the ionic liquid-in-water microemulsions were fabricated by using two kinds of hydrophobic ionic liquid, 1-Butyl-3-methylimidazolium hexafluorophosphate [Bmim][PF 6 ] and 1-Hexyl-3-methylimidazolium hexafluorophosphate [Hmim][PF 6 ] with Tween 20. The ionic liquid droplets in water experience the dielectrophoretic (DEP) forces induced by applying electrical field via a nano-orifice and a micron orifice on the opposite channel walls of a microchannel. The dielectrophoretic behaviors of the ionic liquid-in-water emulsion droplets were investigated under direct current (DC) electric field. The positive and negative DEP behaviors of the ionic liquid-in-water droplets varying with the electrical conductivity of the suspending medium were investigated and two kinds of the ionic liquid droplets of similar sizes were separated by their different DEP behaviors. In addition, the separation of the ionic liquid-in-water droplets by size was conducted. This paper, for the first time to our knowledge, presents the DC-DEP manipulation of the ionic liquid-in-water emulsion droplets by size and by type. This method provides a platform to manipulate the ionic liquid droplets individually. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Cell Patterning for Liver Tissue Engineering via Dielectrophoretic Mechanisms

    Directory of Open Access Journals (Sweden)

    Wan Nurlina Wan Yahya

    2014-07-01

    Full Text Available Liver transplantation is the most common treatment for patients with end-stage liver failure. However, liver transplantation is greatly limited by a shortage of donors. Liver tissue engineering may offer an alternative by providing an implantable engineered liver. Currently, diverse types of engineering approaches for in vitro liver cell culture are available, including scaffold-based methods, microfluidic platforms, and micropatterning techniques. Active cell patterning via dielectrophoretic (DEP force showed some advantages over other methods, including high speed, ease of handling, high precision and being label-free. This article summarizes liver function and regenerative mechanisms for better understanding in developing engineered liver. We then review recent advances in liver tissue engineering techniques and focus on DEP-based cell patterning, including microelectrode design and patterning configuration.

  3. Simulation study of dielectrophoretic assembly of nanowire between electrode pairs

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Quan, E-mail: taq3@pitt.edu; Lan, Fei; Jiang, Minlin [University of Pittsburgh, The Department of Electrical and Computer Engineering (United States); Wei, Fanan [Chinese Academy of Sciences, State Key Laboratory of Robotics, Shenyang Institute of Automation (China); Li, Guangyong, E-mail: gul6@pitt.edu [University of Pittsburgh, The Department of Electrical and Computer Engineering (United States)

    2015-07-15

    Dielectrophoresis (DEP) of rod-shaped nanostructures is attractive because of its exceptional capability to fabricate nanowire-based electronic devices. This efficient manipulation method, however, has a common side effect of assembling a certain number of nanowires at undesired positions. It is therefore essential to understand the underlying physics of DEP of nanowires in order to better guide the assembly. In this work, we propose theoretical methods to characterize the dielectrophoretic force and torque as well as the hydrodynamic drag force and torque on the nanowire (typical length: 10 μm). The trajectory of the nanowire is then simulated based on rigid body dynamics. The nanowire is predicted to either bridge the electrodes or attach on the surface of one electrode. A neighborhood in which the nanowire is more likely to bridge electrodes is found, which is conducive to successful assembly. The simulation study in this work provides us not only a better understanding of the underlying physics but also practical guidance on nanowire assembly by DEP.

  4. Dielectrophoretic assay of bacterial resistance to antibiotics

    International Nuclear Information System (INIS)

    Johari, Juliana; Huebner, Yvonne; Hull, Judith C; Dale, Jeremy W; Hughes, Michael P

    2003-01-01

    The dielectrophoretic collection spectra of antibiotic-sensitive and antibiotic-resistant strains of Staphylococcus epidermidis have been determined. These indicate that in the absence of antibiotic treatment there is a strong similarity between the dielectric properties of sensitive and resistant strains, and that there is a significant difference between the sensitive strains before and after treatment with the antibiotic streptomycin after 24 h exposure. This method offers possibilities for the assessment of bacterial resistance to antibiotics. (note)

  5. A microfluidic device for continuous manipulation of biological cells using dielectrophoresis.

    Science.gov (United States)

    Das, Debanjan; Biswas, Karabi; Das, Soumen

    2014-06-01

    The present study demonstrates the design, simulation, fabrication and testing of a label-free continuous manipulation and separation micro-device of particles/biological cells suspended on medium based on conventional dielectrophoresis. The current dielectrophoretic device uses three planner electrodes to generate non-uniform electric field and induces both p-DEP and n-DEP force simultaneously depending on the dielectric properties of the particles and thus influencing at least two types of particles at a time. Numerical simulations were performed to predict the distribution of non-uniform electric field, DEP force and particle trajectories. The device is fabricated utilizing the advantage of bonding between PDMS and SU8 polymer. The p-DEP particles move away from the center of the streamline, while the n-DEP particles will follow the central streamline along the channel length. Dielectrophoretic effects were initially tested using polystyrene beads followed by manipulation of HeLa cells. In the experiment, it was observed that polystyrene beads in DI water always response as n-DEP up to 1MHz frequency, whereas HeLa cells in PBS medium response as n-DEP up to 400kHz frequency and then it experiences p-DEP up to 1MHz. Further, the microscopic observations of DEP responses of HeLa cells were verified by performing trapping experiment at static condition. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Cantilever-type electrode array-based high-throughput microparticle sorting platform driven by gravitation and negative dielectrophoretic force

    International Nuclear Information System (INIS)

    Kim, Youngho; Kim, Byungkyu; Lee, Junghun; Kim, Younggeun; Shin, Sang-Mo

    2011-01-01

    In this paper, we describe a cantilever-type electrode (CE) array-based high-throughput sorting platform, which is a tool used to separate microparticles using gravitation and negative dielectrophoretic (n-DEP) force. This platform consists of meso-size channels and a CE array, which is designed to separate a large number of target particles by differences in their dielectric material properties (DMP) and the weight of the particles. We employ a two-step separation process, with sedimentation as the first step and n-DEP as the second step. In order to differentiate the weight and the DMP of each particle, we employ the sedimentation phenomena in a vertical channel and the CE-based n-DEP in an inclined channel. By using three kinds of polystyrene beads with diameters of 10, 25 and 50 µm, the optimal population (10 7 beads ml −1 ) of particles and the appropriate length (25 mm) of the vertical channel for high performance were determined experimentally. Conclusively, by combining sedimentation and n-DEP schemes, we achieve 74.5, 94.7 and 100% separation efficiency for sorting microparticles with a diameter of 10, 25 and 50 µm, respectively.

  7. Controlled dielectrophoretic nanowire self-assembly using atomic layer deposition and suspended microfabricated electrodes

    International Nuclear Information System (INIS)

    Baca, Alicia I; Brown, Joseph J; Bright, Victor M; Bertness, Kris A

    2012-01-01

    Effects of design and materials on the dielectrophoretic self-assembly of individual gallium nitride nanowires (GaN NWs) onto microfabricated electrodes have been experimentally investigated. The use of TiO 2 surface coating generated by atomic layer deposition (ALD) improves dielectrophoretic assembly yield of individual GaN nanowires on microfabricated structures by as much as 67%. With a titanium dioxide coating, individual nanowires were placed across suspended electrode pairs in 46% of tests (147 out of 320 total), versus 28% of tests (88 out of 320 total tests) that used uncoated GaN NWs. An additional result from these tests was that suspending the electrodes 2.75 μm above the substrate corresponded with up to 15.8% improvement in overall assembly yield over that of electrodes fabricated directly on the substrate. (paper)

  8. Continuous-flow system and monitoring tools for the dielectrophoretic integration of nanowires in light sensor arrays.

    Science.gov (United States)

    Marín, A García; Núñez, C García; Rodríguez, P; Shen, G; Kim, S M; Kung, P; Piqueras, J; Pau, J L

    2015-03-20

    Although nanowires (NWs) may improve the performance of many optoelectronic devices such as light emitters and photodetectors, the mass commercialization of these devices is limited by the difficult task of finding reliable and reproducible methods to integrate the NWs on foreign substrates. This work shows the fabrication of zinc oxide NWs photodetectors on conventional glass using transparent conductive electrodes to effectively integrate the NWs at specific locations by dielectrophoresis (DEP). The paper describes the careful preparation of NW dispersions by sedimentation and the dielectrophoretic alignment of NWs in a home-made system. This system includes an impedance technique for the assessment of the alignment quality in real time. Following this procedure, ultraviolet photodetectors based on the electrical contacts formed by the DEP process on the transparent electrodes are fabricated. This cost-effective mean of contacting NWs enables front-and back-illumination operation modes, the latter eliminating shadowing effects caused by the deposition of metals. The electro-optical characterization of the devices shows uniform responsivities in the order of 106 A W(-1) below 390 nm under both modes, as well as, time responses of a few seconds.

  9. High-throughput particle manipulation by hydrodynamic, electrokinetic, and dielectrophoretic effects in an integrated microfluidic chip

    KAUST Repository

    Li, Shunbo; Li, Ming; Bougot-Robin, Kristelle; Cao, Wenbin; Yeung Yeung Chau, Irene; Li, Weihua; Wen, Weijia

    2013-01-01

    Integrating different steps on a chip for cell manipulations and sample preparation is of foremost importance to fully take advantage of microfluidic possibilities, and therefore make tests faster, cheaper and more accurate. We demonstrated particle manipulation in an integrated microfluidic device by applying hydrodynamic, electroosmotic (EO), electrophoretic (EP), and dielectrophoretic (DEP) forces. The process involves generation of fluid flow by pressure difference, particle trapping by DEP force, and particle redirect by EO and EP forces. Both DC and AC signals were applied, taking advantages of DC EP, EO and AC DEP for on-chip particle manipulation. Since different types of particles respond differently to these signals, variations of DC and AC signals are capable to handle complex and highly variable colloidal and biological samples. The proposed technique can operate in a high-throughput manner with thirteen independent channels in radial directions for enrichment and separation in microfluidic chip. We evaluated our approach by collecting Polystyrene particles, yeast cells, and E. coli bacteria, which respond differently to electric field gradient. Live and dead yeast cells were separated successfully, validating the capability of our device to separate highly similar cells. Our results showed that this technique could achieve fast pre-concentration of colloidal particles and cells and separation of cells depending on their vitality. Hydrodynamic, DC electrophoretic and DC electroosmotic forces were used together instead of syringe pump to achieve sufficient fluid flow and particle mobility for particle trapping and sorting. By eliminating bulky mechanical pumps, this new technique has wide applications for in situ detection and analysis.

  10. High-throughput particle manipulation by hydrodynamic, electrokinetic, and dielectrophoretic effects in an integrated microfluidic chip

    KAUST Repository

    Li, Shunbo

    2013-03-20

    Integrating different steps on a chip for cell manipulations and sample preparation is of foremost importance to fully take advantage of microfluidic possibilities, and therefore make tests faster, cheaper and more accurate. We demonstrated particle manipulation in an integrated microfluidic device by applying hydrodynamic, electroosmotic (EO), electrophoretic (EP), and dielectrophoretic (DEP) forces. The process involves generation of fluid flow by pressure difference, particle trapping by DEP force, and particle redirect by EO and EP forces. Both DC and AC signals were applied, taking advantages of DC EP, EO and AC DEP for on-chip particle manipulation. Since different types of particles respond differently to these signals, variations of DC and AC signals are capable to handle complex and highly variable colloidal and biological samples. The proposed technique can operate in a high-throughput manner with thirteen independent channels in radial directions for enrichment and separation in microfluidic chip. We evaluated our approach by collecting Polystyrene particles, yeast cells, and E. coli bacteria, which respond differently to electric field gradient. Live and dead yeast cells were separated successfully, validating the capability of our device to separate highly similar cells. Our results showed that this technique could achieve fast pre-concentration of colloidal particles and cells and separation of cells depending on their vitality. Hydrodynamic, DC electrophoretic and DC electroosmotic forces were used together instead of syringe pump to achieve sufficient fluid flow and particle mobility for particle trapping and sorting. By eliminating bulky mechanical pumps, this new technique has wide applications for in situ detection and analysis.

  11. A review of microfabrication techniques and dielectrophoretic microdevices for particle manipulation and separation

    International Nuclear Information System (INIS)

    Li, M; Li, W H; Zhang, J; Alici, G; Wen, W

    2014-01-01

    The development of lab-on-a-chip (LOC) devices over the past decade has attracted growing interest. LOC devices aim to achieve the miniaturization, integration, automation and parallelization of biological and chemical assays. One of the applications, the ability to effectively and accurately manipulate and separate micro- and nano-scale particles in an aqueous solution, is particularly appealing in biological, chemical and medical fields. Among the technologies that have been developed and implemented in microfluidic microsystems for particle manipulation and separation (such as mechanical, inertial, hydrodynamic, acoustic, optical, magnetic and electrical methodologies), dielectrophoresis (DEP) may prove to be the most popular because of its label-free nature, ability to manipulate neutral bioparticles, analyse with high selectivity and sensitivity, compatibility with LOC devices, and easy and direct interface with electronics. The required spatial electric non-uniformities for the DEP effect can be generated by patterning microelectrode arrays within microchannels, or placing insulating obstacles within a microchannel and curving the microchannels. A wide variety of electrode- and insulator-based DEP microdevices have been developed, fabricated, and successfully employed to manipulate and separate bioparticles (i.e. DNA, proteins, bacteria, viruses, mammalian and yeast cells). This review provides an overview of the state-of-the-art of microfabrication techniques and of the structures of dielectrophoretic microdevices aimed towards different applications. The techniques used for particle manipulation and separation based on microfluidics are provided in this paper. In addition, we also present the theoretical background of DEP. (topical review)

  12. Dielectrophoretic focusing integrated pulsed laser activated cell sorting

    Science.gov (United States)

    Zhu, Xiongfeng; Kung, Yu-Chun; Wu, Ting-Hsiang; Teitell, Michael A.; Chiou, Pei-Yu

    2017-08-01

    We present a pulsed laser activated cell sorter (PLACS) integrated with novel sheathless size-independent dielectrophoretic (DEP) focusing. Microfluidic fluorescence activated cell sorting (μFACS) systems aim to provide a fully enclosed environment for sterile cell sorting and integration with upstream and downstream microfluidic modules. Among them, PLACS has shown a great potential in achieving comparable performance to commercial aerosol-based FACS (>90% purity at 25,000 cells sec-1). However conventional sheath flow focusing method suffers a severe sample dilution issue. Here we demonstrate a novel dielectrophoresis-integrated pulsed laser activated cell sorter (DEP-PLACS). It consists of a microfluidic channel with 3D electrodes laid out to provide a tunnel-shaped electric field profile along a 4cmlong channel for sheathlessly focusing microparticles/cells into a single stream in high-speed microfluidic flows. All focused particles pass through the fluorescence detection zone along the same streamline regardless of their sizes and types. Upon detection of target fluorescent particles, a nanosecond laser pulse is triggered and focused in a neighboring channel to generate a rapidly expanding cavitation bubble for precise sorting. DEP-PLACS has achieved a sorting purity of 91% for polystyrene beads at a throughput of 1,500 particle/sec.

  13. Using a Microfluidic-Microelectric Device to Directly Separate Serum/Blood Cells from a Continuous Whole Bloodstream Flow

    Science.gov (United States)

    Wang, Ming-Wen; Jeng, Kuo-Shyang; Yu, Ming-Che; Su, Jui-Chih

    2012-03-01

    To make the rapid separation of serum/blood cells possible in a whole bloodstream flow without centrifugation and Pasteur pipette suction, the first step is to use a microchannel to transport the whole bloodstream into a microdevice. Subsequently, the resulting serum/blood cell is separated from the whole bloodstream by applying other technologies. Creating the serum makes this subsequent separation possible. To perform the actual separation, a microchannel with multiple symmetric curvilinear microelectrodes has been designed on a glass substrate and fabricated with micro-electromechanical system technology. The blood cells can be observed clearly by black-field microscopy imaging. A local dielectrophoretic (DEP) force, obtained from nonuniform electric fields, was used for manipulating and separating the blood cells from a continuous whole bloodstream. The experimental studies show that the blood cells incur a local dielectrophoretic field when they are suspended in a continuous flow (v = 0.02-0.1 cm/s) and exposed to AC fields at a frequency of 200 kHz. Using this device, the symmetric curvilinear microelectrodes provide a local dielectrophoretic field that is sufficiently strong for separating nearby blood cells and purifying the serum in a continuous whole bloodstream flow.

  14. Dielectrophoretic Separation of Live and Dead Monocytes Using 3D Carbon-Electrodes

    Directory of Open Access Journals (Sweden)

    Yagmur Yildizhan

    2017-11-01

    Full Text Available Blood has been the most reliable body fluid commonly used for the diagnosis of diseases. Although there have been promising investigations for the development of novel lab-on-a-chip devices to utilize other body fluids such as urine and sweat samples in diagnosis, their stability remains a problem that limits the reliability and accuracy of readouts. Hence, accurate and quantitative separation and characterization of blood cells are still crucial. The first step in achieving high-resolution characteristics for specific cell subpopulations from the whole blood is the isolation of pure cell populations from a mixture of cell suspensions. Second, live cells need to be purified from dead cells; otherwise, dead cells might introduce biases in the measurements. In addition, the separation and characterization methods being used must preserve the genetic and phenotypic properties of the cells. Among the characterization and separation approaches, dielectrophoresis (DEP is one of the oldest and most efficient label-free quantification methods, which directly purifies and characterizes cells using their intrinsic, physical properties. In this study, we present the dielectrophoretic separation and characterization of live and dead monocytes using 3D carbon-electrodes. Our approach successfully removed the dead monocytes while preserving the viability of the live monocytes. Therefore, when blood analyses and disease diagnosis are performed with enriched, live monocyte populations, this approach will reduce the dead-cell contamination risk and achieve more reliable and accurate test results.

  15. Smoothing type buffer memory device

    International Nuclear Information System (INIS)

    Podorozhnyj, D.M.; Yashin, I.V.

    1990-01-01

    The layout of the micropower 4-bit smoothing type buffer memory device allowing one to record without counting the sequence of input randomly distributed pulses in multi-channel devices with serial poll, is given. The power spent by a memory cell for one binary digit recording is not greater than 0.15 mW, the device dead time is 10 mus

  16. Design of wheel-type walking-assist device

    International Nuclear Information System (INIS)

    Jung, Seung Ho; Kim, Seung Ho; Kim, Chang Hoi; Seo, Yong Chil; Jung, Kyung Min; Lee, Sung Uk

    2006-03-01

    In this research, a outdoor wheel-type walking-assist device is developed to help an elder having a poor muscular strength at legs for walking, sitting and standing up easily at outdoors, and also for going and downing stairs. In conceptually designing, the environments of an elder's activity, the size of an elder's body and a necessary function of helping an elder are considered. This device has 4 wheels for stability. When an elder walks in incline plane with the proposed device, a rear-wing is rotated to keep the supporting device horizontal, regardless of an angle of inclination. A height-controlling device, which can control the height of the supporting device for adjusting an elder's height, is varied vertically to help an elder to sit and stand-up easily. Moreover, a outdoor wheel-type walking-assist device is conceptually designed and is made. In order to design it, the preview research is investigated firstly. On the basis of the proposed walking-assist device, the outdoor walking-assist device is designed and made. The outdoor wheel-type walking-assist device can go and down stairs automatically. This device go up and down the stair of having maximum 20cm height and an angle of 25 degrees with maximum 4 sec/stairs speed, and move at flatland with 60cm/sec speed

  17. Dielectrophoretic manipulation of human chromosomes in microfluidic channels: extracting chromosome dielectric properties

    DEFF Research Database (Denmark)

    Clausen, Casper Hyttel; Dimaki, Maria; Buckley, Sonia

    2011-01-01

    An investigation of the dielectric properties of polyamine buffer prepared human chromosomes is presented in this paper. Chromosomes prepared in this buffer are only a few micrometers in size and shaped roughly like spherical discs. Dielectrophoresis was therefore chosen as the method...... of manipulation combined with a custom designed microfluidic system containing the required electrodes for dielectrophoresis experiments. Our results show that although this system is presently not able to distinguish between the different chromosomes, it can provide average data for the dielectric properties...... of human chromosomes in polyamine buffer. These can then be used to optimize system designs for further characterization and even sorting. The experimental data from the dielectrophoretic manipulation were combined with theoretical calculations to extract a range of values for the permittivity...

  18. Electric field and dielectrophoretic force on a dielectric particle chain in a parallel-plate electrode system

    International Nuclear Information System (INIS)

    Techaumnat, B; Eua-arporn, B; Takuma, T

    2004-01-01

    This paper presents results of calculations of the electric field and dielectrophoretic force on a dielectric particle chain suspended in a host liquid lying between parallel-plate electrodes. The method of calculation is based on the method of multipole images using the multipole re-expansion technique. We have investigated the effect of the particle permittivity, the tilt angle (between the chain and the applied field) and the chain arrangement on the electric field and force. The results show that the electric field intensification rises in accordance with the increase in the ratio of the particle-to-liquid permittivity, Γ ε . The electric field at the contact point between the particles decreases with increasing tilt angle, while the maximal field at the contact point between the particles and the plate electrodes is almost unchanged. The maximal field can be approximated by a simple formula, which is a quadratic function of Γ ε . The dielectrophoretic force depends significantly on the distance from other particles or an electrode. However, for the tilt angles in this paper, the horizontal force on the upper particle of the chain always has the direction opposite to the shear direction. The maximal horizontal force of a chain varies proportional to (Γ ε - 1) 1.7 if the particles in the chain are still in contact with each other. The approximated force, based on the force on an isolated chain, has been compared with our calculation results. The comparison shows that no approximation model agrees well with our results throughout the range of permittivity ratios

  19. Type testing of devices with inserted radioactive sources

    International Nuclear Information System (INIS)

    Rolle, A.; Droste, B.; Dombrowski, H.

    2006-01-01

    In Germany devices with inserted radioactive sources can get a type approval if they comply with specific requirements. Whoever operates a device whose type has been approved in accordance with the German Radiation Protection Ordinance does not need an individual authorization. Such type approvals for free use are granted by the Federal Office for Radiation Protection (B.f.S.) on the basis of type testing performed by the Physikalisch-Technische Bundesanstalt (P.T.B.), the national metrology institute, and the Bundesanstalt fur Materialforschung und -prufung (B.A.M.), the Federal Institute for Materials Research and Testing. Main aspects of the assessment are the activity of the radioactive sources, the dose equivalent rate near the devices, the tamper-proofness and leak-tightness of the sources and the safety of the construction of the devices. With the new Radiation Protection Ordinance in 2001, more stringent requirements for a type approval were established. Experiences with the new regulations and the relevant assessment criteria applied by P.T.B. and B.A.M. will be presented. (authors)

  20. Performance test of wet type decontamination device

    International Nuclear Information System (INIS)

    Lee, E. P.; Kim, E. G.; Min, D. K.; Jun, Y. B.; Lee, H. K.; Seu, H. S.; Kwon, H. M.; Hong, K.P.

    2003-01-01

    The intervention area located at rear hot cell can be contaminated by hot cell maintenance work. For effective decontamination of the intervention floor a wet type decontamination device was developed. The device was assembled with a brush rotating part, a washing liquid supplying part, an intake part for recovering contaminated liquid and a device moving cart part. The device was made of stainless steel for easy decontamination and corrosion resistance. The function test carried out at intervention area of the PIE facility showed good performance

  1. H+-type and OH- -type biological protonic semiconductors and complementary devices.

    Science.gov (United States)

    Deng, Yingxin; Josberger, Erik; Jin, Jungho; Roudsari, Anita Fadavi; Rousdari, Anita Fadavi; Helms, Brett A; Zhong, Chao; Anantram, M P; Rolandi, Marco

    2013-10-03

    Proton conduction is essential in biological systems. Oxidative phosphorylation in mitochondria, proton pumping in bacteriorhodopsin, and uncoupling membrane potentials by the antibiotic Gramicidin are examples. In these systems, H(+) hop along chains of hydrogen bonds between water molecules and hydrophilic residues - proton wires. These wires also support the transport of OH(-) as proton holes. Discriminating between H(+) and OH(-) transport has been elusive. Here, H(+) and OH(-) transport is achieved in polysaccharide- based proton wires and devices. A H(+)- OH(-) junction with rectifying behaviour and H(+)-type and OH(-)-type complementary field effect transistors are demonstrated. We describe these devices with a model that relates H(+) and OH(-) to electron and hole transport in semiconductors. In turn, the model developed for these devices may provide additional insights into proton conduction in biological systems.

  2. H+-type and OH−-type biological protonic semiconductors and complementary devices

    Science.gov (United States)

    Deng, Yingxin; Josberger, Erik; Jin, Jungho; Rousdari, Anita Fadavi; Helms, Brett A.; Zhong, Chao; Anantram, M. P.; Rolandi, Marco

    2013-01-01

    Proton conduction is essential in biological systems. Oxidative phosphorylation in mitochondria, proton pumping in bacteriorhodopsin, and uncoupling membrane potentials by the antibiotic Gramicidin are examples. In these systems, H+ hop along chains of hydrogen bonds between water molecules and hydrophilic residues – proton wires. These wires also support the transport of OH− as proton holes. Discriminating between H+ and OH− transport has been elusive. Here, H+ and OH− transport is achieved in polysaccharide- based proton wires and devices. A H+- OH− junction with rectifying behaviour and H+-type and OH−-type complementary field effect transistors are demonstrated. We describe these devices with a model that relates H+ and OH− to electron and hole transport in semiconductors. In turn, the model developed for these devices may provide additional insights into proton conduction in biological systems. PMID:24089083

  3. Focused ion beam patterning to dielectrophoretically assemble single nanowire based devices

    International Nuclear Information System (INIS)

    La Ferrara, V; Massera, E; Francia, G Di; Alfano, B

    2010-01-01

    Direct-write processing is increasingly taking place in nanodevice fabrication. In this work, Focused Ion Beam (FIB), a powerful tool in maskless micromachining, is used for electrode patterning onto a silicon/silicon nitride substrate. Then a single palladium nanowire is assembled between electrodes by means of dielectrophoresis (DEP). The nanowire morphology depends on the electrode pattern when DEP conditions are fixed. FIB/DEP combination overcomes the problem of nanowire electrical contamination due to gallium ion bombardment and the as-grown nanowire retains its basic electrical properties. Single nanowire based devices have been fabricated with this novel approach and have been tested as hydrogen sensors, confirming the reliability of this technology.

  4. Fixed type incore measuring device

    International Nuclear Information System (INIS)

    Oda, Naotaka; Ito, Hitoshi; Maeda, Hiroyuki

    1998-01-01

    The present invention concerns a measuring device using gamma thermometers to be used in a BWR type reactor. An input switch is inserted to the vicinity of a detection signal input portion of a signal cable connecting GT with the detection signal input portion of a fixed type incore measuring device, and a loop resistance measuring means is disposed to the input switch on the side of the GT by way of a measurement switch. Upon measuring loop resistance, the GT measuring circuit is switched from the detection signal input portion to the loop resistance measuring means by a switching operation of the input switch and the measurement switch thereby enabling to confirm the value of the loop resistance. In addition, the lowering of the voltage in the loop resistance is compensated to confirm the accurate measurement values to be used thereby enabling to measure GT detection signals accurately. A diagnosing means for diagnosing the state of GT based on the results of the measurement for the loop resistance is disposed, and the results are reported to an operator. (N.H.)

  5. Nanotip analysis for dielectrophoretic concentration of nanosized viral particles.

    Science.gov (United States)

    Yeo, Woon-Hong; Lee, Hyun-Boo; Kim, Jong-Hoon; Lee, Kyong-Hoon; Chung, Jae-Hyun

    2013-05-10

    Rapid and sensitive detection of low-abundance viral particles is strongly demanded in health care, environmental control, military defense, and homeland security. Current detection methods, however, lack either assay speed or sensitivity, mainly due to the nanosized viral particles. In this paper, we compare a dendritic, multi-terminal nanotip ('dendritic nanotip') with a single terminal nanotip ('single nanotip') for dielectrophoretic (DEP) concentration of viral particles. The numerical computation studies the concentration efficiency of viral particles ranging from 25 to 100 nm in radius for both nanotips. With DEP and Brownian motion considered, when the particle radius decreases by two times, the concentration time for both nanotips increases by 4-5 times. In the computational study, a dendritic nanotip shows about 1.5 times faster concentration than a single nanotip for the viral particles because the dendritic structure increases the DEP-effective area to overcome the Brownian motion. For the qualitative support of the numerical results, the comparison experiment of a dendritic nanotip and a single nanotip is conducted. Under 1 min of concentration time, a dendritic nanotip shows a higher sensitivity than a single nanotip. When the concentration time is 5 min, the sensitivity of a dendritic nanotip for T7 phage is 10(4) particles ml(-1). The dendritic nanotip-based concentrator has the potential for rapid identification of viral particles.

  6. Nanotip analysis for dielectrophoretic concentration of nanosized viral particles

    International Nuclear Information System (INIS)

    Yeo, Woon-Hong; Lee, Hyun-Boo; Kim, Jong-Hoon; Chung, Jae-Hyun; Lee, Kyong-Hoon

    2013-01-01

    Rapid and sensitive detection of low-abundance viral particles is strongly demanded in health care, environmental control, military defense, and homeland security. Current detection methods, however, lack either assay speed or sensitivity, mainly due to the nanosized viral particles. In this paper, we compare a dendritic, multi-terminal nanotip (‘dendritic nanotip’) with a single terminal nanotip (‘single nanotip’) for dielectrophoretic (DEP) concentration of viral particles. The numerical computation studies the concentration efficiency of viral particles ranging from 25 to 100 nm in radius for both nanotips. With DEP and Brownian motion considered, when the particle radius decreases by two times, the concentration time for both nanotips increases by 4–5 times. In the computational study, a dendritic nanotip shows about 1.5 times faster concentration than a single nanotip for the viral particles because the dendritic structure increases the DEP-effective area to overcome the Brownian motion. For the qualitative support of the numerical results, the comparison experiment of a dendritic nanotip and a single nanotip is conducted. Under 1 min of concentration time, a dendritic nanotip shows a higher sensitivity than a single nanotip. When the concentration time is 5 min, the sensitivity of a dendritic nanotip for T7 phage is 10 4 particles ml −1 . The dendritic nanotip-based concentrator has the potential for rapid identification of viral particles. (paper)

  7. Iterative Dipole Moment Method for the Dielectrophoretic Particle-Particle Interaction in a DC Electric Field

    Directory of Open Access Journals (Sweden)

    Qing Zhang

    2018-01-01

    Full Text Available Electric force is the most popular technique for bioparticle transportation and manipulation in microfluidic systems. In this paper, the iterative dipole moment (IDM method was used to calculate the dielectrophoretic (DEP forces of particle-particle interactions in a two-dimensional DC electric field, and the Lagrangian method was used to solve the transportation of particles. It was found that the DEP properties and whether the connection line between initial positions of particles perpendicular or parallel to the electric field greatly affect the chain patterns. In addition, the dependence of the DEP particle interaction upon the particle diameters, initial particle positions, and the DEP properties have been studied in detail. The conclusions are advantageous in elelctrokinetic microfluidic systems where it may be desirable to control, manipulate, and assemble bioparticles.

  8. Gender Differences and Demographics and Type of Cardiac Device ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... relation between gender and cardiac device implantation indications and ... cerebrovascular disease, DM = diabetes mellitus, HT = hypertension,. PAD = peripheral arterial ... Figure 2: Trend of device types according to years.

  9. Adolescents' Use of Basic, Intermediate, and Advanced Device Types for Vaping.

    Science.gov (United States)

    Pepper, Jessica K; MacMonegle, Anna J; Nonnemaker, James M

    2017-12-23

    Advanced models of electronic vaping products (EVPs) likely pose a greater risk to adolescent health than basic or intermediate models because advanced models deliver nicotine more effectively and heat e-liquid to higher temperatures, producing more harmful chemical emissions. However, little is known about adolescents' risk factors for using different device types. We used social media to recruit an online sample of 1,508 U.S. adolescents aged 15-17 who reported past 30-day use of e-cigarettes. We assessed tobacco use, beliefs and knowledge about EVPs, and EVP use behavior, including the device type participants use most frequently. We used multinomial logistic regression to examine differences between adolescents who usually use intermediate versus basic and advanced versus basic devices. Most respondents usually used modifiable advanced devices (56.8%) rather than basic "cigalike" (14.5%) or pen-style intermediate (28.7%) devices. Use of multiple device types was common, particularly among those who primarily used basic devices. Younger age and less frequent vaping were associated with mainly using basic devices. Adolescents who were older, male, personally bought their main device, and had ever mixed e-liquids were at elevated risk for usually using advanced devices. Adolescents who primarily use basic devices may be newer users who are experimenting with multiple devices. Future research should examine which adolescents are most likely to transition to advanced devices in order to develop targeted interventions. Regulators should consider strategies to reduce access to all types of EVPs, such as better enforcement of the current ban on sales to minors. This research addresses two gaps in research on adolescent electronic vaping product use: (1) characterizing use of advanced devices as distinct from intermediate devices rather than grouping them together and (2) examining factors associated with use of specific device types. This study suggests that there

  10. Escherichia coli Fiber Sensors Using Concentrated Dielectrophoretic Force with Optical Defocusing Method.

    Science.gov (United States)

    Tai, Yi-Hsin; Lee, Chia-Wei; Chang, Dao-Ming; Lai, Yu-Sheng; Huang, Ding-Wei; Wei, Pei-Kuen

    2018-05-25

    A sensitive tapered optical fiber tip combined with dielectrophoretic (DEP) trapping was used for rapid and label-free detection of bacteria in water. The angular spectrum of the optical field at the fiber tip was changed with the surrounding refractive index (RI). By measuring far-field intensity change at the defocus plane, the intensity sensitivity was up to 95 200%/RIU (RI unit), and the detection limit was 5.2 × 10 -6 RIU at 0.5% intensity stability. By applying an AC voltage to a Ti/Al coated fiber tip and an indium-tin-oxide glass, the DEP force effectively trapped the Escherichia coli ( E. coli) near the fiber tip. Those bacteria can be directly measured from optical intensity change due to the increase of surrounding RI. By immobilizing the antibody on the Ti/Al fiber tip, the tests for specific K12 bacteria and nonspecific BL21 bacteria verified the specificity. The antibody-immobilized Ti/Al coated fiber tip with DEP trapping can detect bacteria at a concentration about 100 CFU/mL.

  11. Recent Developments in p-Type Oxide Semiconductor Materials and Devices

    KAUST Repository

    Wang, Zhenwei

    2016-02-16

    The development of transparent p-type oxide semiconductors with good performance may be a true enabler for a variety of applications where transparency, power efficiency, and greater circuit complexity are needed. Such applications include transparent electronics, displays, sensors, photovoltaics, memristors, and electrochromics. Hence, here, recent developments in materials and devices based on p-type oxide semiconductors are reviewed, including ternary Cu-bearing oxides, binary copper oxides, tin monoxide, spinel oxides, and nickel oxides. The crystal and electronic structures of these materials are discussed, along with approaches to enhance valence-band dispersion to reduce effective mass and increase mobility. Strategies to reduce interfacial defects, off-state current, and material instability are suggested. Furthermore, it is shown that promising progress has been made in the performance of various types of devices based on p-type oxides. Several innovative approaches exist to fabricate transparent complementary metal oxide semiconductor (CMOS) devices, including novel device fabrication schemes and utilization of surface chemistry effects, resulting in good inverter gains. However, despite recent developments, p-type oxides still lag in performance behind their n-type counterparts, which have entered volume production in the display market. Recent successes along with the hurdles that stand in the way of commercial success of p-type oxide semiconductors are presented.

  12. Recent Developments in p-Type Oxide Semiconductor Materials and Devices

    KAUST Repository

    Wang, Zhenwei; Nayak, Pradipta K.; Caraveo-Frescas, Jesus Alfonso; Alshareef, Husam N.

    2016-01-01

    The development of transparent p-type oxide semiconductors with good performance may be a true enabler for a variety of applications where transparency, power efficiency, and greater circuit complexity are needed. Such applications include transparent electronics, displays, sensors, photovoltaics, memristors, and electrochromics. Hence, here, recent developments in materials and devices based on p-type oxide semiconductors are reviewed, including ternary Cu-bearing oxides, binary copper oxides, tin monoxide, spinel oxides, and nickel oxides. The crystal and electronic structures of these materials are discussed, along with approaches to enhance valence-band dispersion to reduce effective mass and increase mobility. Strategies to reduce interfacial defects, off-state current, and material instability are suggested. Furthermore, it is shown that promising progress has been made in the performance of various types of devices based on p-type oxides. Several innovative approaches exist to fabricate transparent complementary metal oxide semiconductor (CMOS) devices, including novel device fabrication schemes and utilization of surface chemistry effects, resulting in good inverter gains. However, despite recent developments, p-type oxides still lag in performance behind their n-type counterparts, which have entered volume production in the display market. Recent successes along with the hurdles that stand in the way of commercial success of p-type oxide semiconductors are presented.

  13. Travelling type monitoring and inspection device

    International Nuclear Information System (INIS)

    Ito, Takao; Maruki, Hideaki.

    1994-01-01

    The present invention sufficiently ensures video output images even if lenses of a television camera of a monitoring means are degraded to reduce the quantity of transmission light. That is, a light amount control mechanism capable of controlling the quantity of illumination light irradiated from an illumination device at an output level of a sensor of an inspection device main body. A test chart for measuring a luminance which is an output level of the sensor is disposed. During plant operation, the lenses of the television camera undergo influences of radioactivity and are degraded to reduce the quantity of transmission light on every periodical monitoring and inspection using a travelling type monitoring inspection device. In this case, the test chart disposed near the equipment to be monitored and inspected is caught by the television camera to measure a sensor output luminance. Then, the light amount control mechanism of the illumination device is controlled so as to provide a luminance which has been set at an initial stage of the plant inspection. With such procedures, video data of the objective equipment to be monitored and inspected can be obtained at a constant luminance during inspection. (I.S.)

  14. Diffractive optical devices produced by light-assisted trapping of nanoparticles.

    Science.gov (United States)

    Muñoz-Martínez, J F; Jubera, M; Matarrubia, J; García-Cabañes, A; Agulló-López, F; Carrascosa, M

    2016-01-15

    One- and two-dimensional diffractive optical devices have been fabricated by light-assisted trapping and patterning of nanoparticles. The method is based on the dielectrophoretic forces appearing in the vicinity of a photovoltaic crystal, such as Fe:LiNbO3, during or after illumination. By illumination with the appropriate light distribution, the nanoparticles are organized along patterns designed at will. One- and two-dimensional diffractive components have been achieved on X- and Z-cut Fe:LiNbO3 crystals, with their polar axes parallel and perpendicular to the crystal surface, respectively. Diffraction gratings with periods down to around a few micrometers have been produced using metal (Al, Ag) nanoparticles with radii in the range of 70-100 nm. Moreover, several 2D devices, such as Fresnel zone plates, have been also produced showing the potential of the method. The diffractive particle patterns remain stable when light is removed. A method to transfer the diffractive patterns to other nonphotovoltaic substrates, such as silica glass, has been also reported.

  15. Scattering measurements in Tokamak type devices

    International Nuclear Information System (INIS)

    Matoba, Tohru

    1975-03-01

    Theories, experiments and proposals for light scattering in Tokamak type devices are reviewed. Thomson scattering, measuring method of the current density distribution by scattering and resonance fluorescence are summarily described. These methods may be useful for diagnosis of the fusion plasmas. The report may help planning of the measuring apparatus for the fusion plasmas in future. (auth.)

  16. Vibration-type particle separation device with piezoceramic vibrator

    Science.gov (United States)

    Ooe, Katsutoshi; Doi, Akihiro

    2008-12-01

    During hemanalysis, it is necessary to separate blood cells from whole blood. Many blood separation methods, for example, centrifugation and filtering, are in practical use. However, the use of these methods involves problems from the perspectives of processing speed and processing volume. We develop new types of blood separation devices that use piezo-ceramic vibrators. The first device uses a capillary. One end of the capillary is fixed to the device frame, and the other is fixed to a piezo-ceramic vibrator. The vibrator transmits bending waves to the capillary. This device can process only a small amount of solution; therefore, it is not suitable for hemanalysis. In order to solve this problem, we developed a second device; this device has a pair of thin glass plates with a small gap as a substitute for the capillary used in the first device. These devices are based on the fact that particles heavier than water move toward transverse velocity antinodes while those lighter than water move toward velocity nodes. In this report, we demonstrate the highspeed separation of silica microbeads and 50-vol% glycerol water by using these devices. The first device can separate the abovementioned solution within 3 min while the second can separate it within 1 min. Both devices are driven by a rectangular wave of 15 to 20 Vpp. Furthermore, it has been confirmed that red blood cells are separated from diluted whole blood using the first device within approximately 1 min. These devices have transparency, so they can compose as the analysis system with the chemical analyzer easily.

  17. Design study of a bar-type EMR device

    KAUST Repository

    Sun, Jian; Gooneratne, Chinthaka Pasan; Kosel, Jü rgen

    2012-01-01

    It is well known that extraordinary magnetoresistance (EMR) depends on the geometric parameters of the EMR device and the locations of the electrodes. In this paper, the performance of a bar-type EMR device is simulated with respect to the device geometry and electrode locations. The performance is evaluated with regards to the output sensitivity of the device, rather than the often analyzed EMR ratio, since it is more relevant than the EMR ratio for potential applications ranging from read heads to smart biomedical sensors. The results obtained with the finite element method show the dependence of the output sensitivity on the device geometry the placements of the electric contacts as well as the strength of the applied magnetic field in different configurations and allow finding the optimum parameters. Within the studied range of -1 to 1 T both IVVI and VIIV configurations show very similar behavior. For EMR sensors of high sensitivity, the results suggest that a simple two-contact device would provide the best performance replacing the conventional four-contact design. © 2012 IEEE.

  18. Design study of a bar-type EMR device

    KAUST Repository

    Sun, Jian

    2012-05-01

    It is well known that extraordinary magnetoresistance (EMR) depends on the geometric parameters of the EMR device and the locations of the electrodes. In this paper, the performance of a bar-type EMR device is simulated with respect to the device geometry and electrode locations. The performance is evaluated with regards to the output sensitivity of the device, rather than the often analyzed EMR ratio, since it is more relevant than the EMR ratio for potential applications ranging from read heads to smart biomedical sensors. The results obtained with the finite element method show the dependence of the output sensitivity on the device geometry the placements of the electric contacts as well as the strength of the applied magnetic field in different configurations and allow finding the optimum parameters. Within the studied range of -1 to 1 T both IVVI and VIIV configurations show very similar behavior. For EMR sensors of high sensitivity, the results suggest that a simple two-contact device would provide the best performance replacing the conventional four-contact design. © 2012 IEEE.

  19. Sensitivity Enhancement of a Vertical-Type CMOS Hall Device for a Magnetic Sensor

    Directory of Open Access Journals (Sweden)

    Sein Oh

    2018-01-01

    Full Text Available This study presents a vertical-type CMOS Hall device with improved sensitivity to detect a 3D magnetic field in various types of sensors or communication devices. To improve sensitivity, trenches are implanted next to the current input terminal, so that the Hall current becomes maximum. The effect of the dimension and location of trenches on sensitivity is simulated in the COMSOL simulator. A vertical-type Hall device with a width of 16 μm and a height of 2 μm is optimized for maximum sensitivity. The simulation result shows that it has a 23% better result than a conventional vertical-type CMOS Hall device without a trench.

  20. Reactor scram device for FBR type reactor

    International Nuclear Information System (INIS)

    Kumasaka, Katsuyuki; Arashida, Genji; Itooka, Satoshi.

    1991-01-01

    In a control rod attaching structure in a reactor scram device of an FBR type reactor, an anti-rising mechanism proposed so far against external upward force upon occurrence of earthquakes relies on the engagement of a mechanical structure but temperature condition is not taken into consideration. Then, in the present invention, a material having curie temperature characteristics and which exhibits ferromagnetism only under low temperature condition and a magnet device are disposed to one of a movable control rod and a portion secured to the reactor. Alternatively, a bimetal member or a shape memory alloy which actuates to fix to the mating member only under low temperature condition is secured. The fixing device is adapted to operate so as to secure the control rods when the low temperature state is caused depending on the temperature condition. With such a constitution, when the control rods are separated from a driving device, they are prevented from rising even if they undergo external upward force due to earthquakes and so on, which can improve the reactor safety. (N.H.)

  1. Helical-type device and laser fusion. Rivals for tokamak-type device at n-fusion development in Japan

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    Under the current policy on the research and development of nuclear fusion in Japan, as enunciated by the Atomic Energy Commission of Japan, the type of a prototype fusion reactor will be chosen after 2020 from tokamak, helical or some other type including the inertial confinement fusion using lasers. A prototype fusion reactor is the next step following the tokamak type International Thermonuclear Experimental Reactor (ITER). With the prototype reactor, the feasibility as a power plant will be examined. At present the main research and development of nuclear fusion in Japan are on tokamak type, which have been promoted by Japan Atomic Energy Research Institute (JAERI). As for the other types of nuclear fusion, researches have been carried out on the helical type in Kyoto University and National Institute for Fusion Science (NIFS), the mirror type in Tsukuba University, the tokamak type using superconductive coils in Kyushu University, and the laser fusion in Osaka University. The features and the present state of research and development of the Large Helical Device and the laser fusion which is one step away from the break-even condition are reported. (K.I.)

  2. PERFORMANCE EVALUATION OF TYPE I MARINE SANITATION DEVICES

    Science.gov (United States)

    This performance test was designed to evaluate the effectiveness of two Type I Marine Sanitation Devices (MSDs): the Electro Scan Model EST 12, manufactured by Raritan Engineering Company, Inc., and the Thermopure-2, manufactured by Gross Mechanical Laboratories, Inc. Performance...

  3. Dielectrophoretic capture and genetic analysis of single neuroblastoma tumor cells

    Directory of Open Access Journals (Sweden)

    Erica L Carpenter

    2014-07-01

    Full Text Available Our understanding of the diversity of cells that escape the primary tumor and seed micrometastases remains rudimentary, and approaches for studying circulating and disseminated tumor cells have been limited by low throughput and sensitivity, reliance on single parameter sorting, and a focus on enumeration rather than phenotypic and genetic characterization. Here we utilize a highly sensitive microfluidic and dielectrophoretic approach for the isolation and genetic analysis of individual tumor cells. We employed fluorescence labeling to isolate 208 single cells from spiking experiments conducted with 11 cell lines, including 8 neuroblastoma cell lines, and achieved a capture sensitivity of 1 tumor cell per 106 white blood cells. Sample fixation or freezing had no detectable effect on cell capture. Point mutations were accurately detected in the whole genome amplification product of captured single tumor cells but not in negative control white blood cells. We applied this approach to capture 144 single tumor cells from 10 bone marrow samples from patients suffering from neuroblastoma. In this pediatric malignancy, high-risk patients often exhibit wide-spread hematogenous metastasis, but access to primary tumor can be difficult or impossible. Here we used flow-based sorting to pre-enrich samples with tumor involvement below 0.02%. For all patients for whom a mutation in the Anaplastic Lymphoma Kinase gene had already been detected in their primary tumor, the same mutation was detected in single cells from their marrow. These findings demonstrate a novel, non-invasive, and adaptable method for the capture and genetic analysis of single tumor cells from cancer patients.

  4. Silicon based nanogap device for studying electrical transport phenomena in molecule-nanoparticle hybrids

    International Nuclear Information System (INIS)

    Strobel, Sebastian; Hernandez, Rocio Murcia; Hansen, Allan G; Tornow, Marc

    2008-01-01

    We report the fabrication and characterization of vertical nanogap electrode devices using silicon-on-insulator substrates. Using only standard silicon microelectronic process technology, nanogaps down to 26 nm electrode separation were prepared. Transmission electron microscopy cross-sectional analysis revealed the well defined material architecture of the nanogap, comprising two electrodes of dissimilar geometrical shape. This asymmetry is directly reflected in transport measurements on molecule-nanoparticle hybrid systems formed by self-assembling a monolayer of mercaptohexanol on the electrode surface and the subsequent dielectrophoretic trapping of 30 nm diameter Au nanoparticles. The observed Coulomb staircase I-V characteristic measured at T = 4.2 K is in excellent agreement with theoretical modelling, whereby junction capacitances of the order of a few 10 -18 farad and asymmetric resistances of 30 and 300 MΩ, respectively, are also supported well by our independent estimates for the formed double barrier tunnelling system. We propose our nanoelectrode system for integrating novel functional electronic devices such as molecular junctions or nanoparticle hybrids into existing silicon microelectronic process technology

  5. Silicon based nanogap device for studying electrical transport phenomena in molecule-nanoparticle hybrids

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, Sebastian; Hernandez, Rocio Murcia [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall 3, 85748 Garching (Germany); Hansen, Allan G; Tornow, Marc [Institut fuer Halbleitertechnik, Technische Universitaet Braunschweig, Hans-Sommer-Strasse 66, 38106 Braunschweig (Germany)], E-mail: m.tornow@tu-bs.de

    2008-09-17

    We report the fabrication and characterization of vertical nanogap electrode devices using silicon-on-insulator substrates. Using only standard silicon microelectronic process technology, nanogaps down to 26 nm electrode separation were prepared. Transmission electron microscopy cross-sectional analysis revealed the well defined material architecture of the nanogap, comprising two electrodes of dissimilar geometrical shape. This asymmetry is directly reflected in transport measurements on molecule-nanoparticle hybrid systems formed by self-assembling a monolayer of mercaptohexanol on the electrode surface and the subsequent dielectrophoretic trapping of 30 nm diameter Au nanoparticles. The observed Coulomb staircase I-V characteristic measured at T = 4.2 K is in excellent agreement with theoretical modelling, whereby junction capacitances of the order of a few 10{sup -18} farad and asymmetric resistances of 30 and 300 M{omega}, respectively, are also supported well by our independent estimates for the formed double barrier tunnelling system. We propose our nanoelectrode system for integrating novel functional electronic devices such as molecular junctions or nanoparticle hybrids into existing silicon microelectronic process technology.

  6. Silicon based nanogap device for studying electrical transport phenomena in molecule-nanoparticle hybrids.

    Science.gov (United States)

    Strobel, Sebastian; Hernández, Rocío Murcia; Hansen, Allan G; Tornow, Marc

    2008-09-17

    We report the fabrication and characterization of vertical nanogap electrode devices using silicon-on-insulator substrates. Using only standard silicon microelectronic process technology, nanogaps down to 26 nm electrode separation were prepared. Transmission electron microscopy cross-sectional analysis revealed the well defined material architecture of the nanogap, comprising two electrodes of dissimilar geometrical shape. This asymmetry is directly reflected in transport measurements on molecule-nanoparticle hybrid systems formed by self-assembling a monolayer of mercaptohexanol on the electrode surface and the subsequent dielectrophoretic trapping of 30 nm diameter Au nanoparticles. The observed Coulomb staircase I-V characteristic measured at T = 4.2 K is in excellent agreement with theoretical modelling, whereby junction capacitances of the order of a few 10(-18) farad and asymmetric resistances of 30 and 300 MΩ, respectively, are also supported well by our independent estimates for the formed double barrier tunnelling system. We propose our nanoelectrode system for integrating novel functional electronic devices such as molecular junctions or nanoparticle hybrids into existing silicon microelectronic process technology.

  7. Numerical comparison between Maxwell stress method and equivalent multipole approach for calculation of the dielectrophoretic force in single-cell traps.

    Science.gov (United States)

    Rosales, Carlos; Lim, Kian Meng

    2005-06-01

    This paper presents detailed numerical calculations of the dielectrophoretic force in traps designed for single-cell trapping. A trap with eight planar electrodes is studied for spherical and ellipsoidal particles using the boundary element method (BEM). Multipolar approximations of orders one to three are compared with the full Maxwell stress tensor (MST) calculation of the electrical force on spherical particles. Ellipsoidal particles are also studied, but in their case only the dipolar approximation is available for comparison with the MST solution. The results show that a small number of multipolar terms need to be considered in order to obtain accurate results for spheres, even in the proximity of the electrodes, and that the full MST calculation is only required in the study of non-spherical particles.

  8. Effect of island shape on dielectrophoretic assembly of metal nanoparticle chains in a conductive-island-based microelectrode system

    International Nuclear Information System (INIS)

    Ding, Haitao; Shao, Jinyou; Ding, Yucheng; Liu, Weiyu; Li, Xiangming; Tian, Hongmiao; Zhou, Yaopei

    2015-01-01

    Highlights: • Conductive island shape influences the dynamic process occurring in DEP assembly of 10 nm gold nanoparticles in a conductive-island-based microelectrode system. • The DEP-assembled nanoparticle wires form a straighter conduction path with the increase in the geometric angle of conductive island tip. • The different island shapes distort the DEP force distribution and increase the local electrothermally induced fluid flow to different extents, which is important for the morphology and electrical conductance quality of the DEP-assembled metal nanoparticle chains. - Abstract: The electrical conduction quality of an electric circuit connection formed by dielectrophoretic (DEP)-assembled metal nanoparticle wires between small conductive elements plays a significant role in electronic devices. One of the major challenges for improving the electrical conductance of nanowires is optimizing their geometric morphology. So far, the electrical conduction quality has been enhanced by optimizing the AC frequency and conductivity of nanoparticle suspensions. Herein, the effect of the conductive island shapes on the dynamic process occurring in a DEP assembly of 10 nm gold nanoparticles was investigated in a conductive-island-based microelectrode system. The nanoparticle wires between the microelectrodes were assembled in situ from colloidal suspensions. The wires were grown in a much straighter route by increasing the geometric angle of the conductive-island tip. To validate the experiments, the effects of mutual DEP interactions and electrothermally induced fluid flow on the dynamic behavior of particle motion for different island geometric configurations in the conductive-island-based microelectrode system were determined by numerical simulations. The simulation results are consistent with those of experiments. This indicates that different conductive island shapes change the distribution of DEP force and increase the electrothermally induced fluid flow to

  9. Privacy Management on Facebook: Do Device Type and Location of Posting Matter?

    Directory of Open Access Journals (Sweden)

    Jennifer Jiyoung Suh

    2015-10-01

    Full Text Available People’s information sharing on Facebook often happens through mobile devices allowing for posting from different locations. Despite the potential contextual differences in content sharing, the literature on online privacy management rarely takes into consideration the type of device and the type of location from which people post content. Do these aspects of Facebook use affect how people share information online? Analyzing Facebook posts young adults shared from different devices and different locations, this article examines the effectiveness of users’ privacy management. By comparing the intended audience with the actual audience of each post, we find considerable mismatch between the two despite most participants expressing confidence in their ability to manage their information on the site. Posts that are accidentally shared with “public”—potentially anyone on the web—are more likely to be shared from non-mobile devices. Interview data reveal that this happens despite the fact that most participants consider non-mobile devices more reliable and convenient to use than mobile devices.

  10. Plykin type attractor in electronic device simulated in MULTISIM

    Science.gov (United States)

    Kuznetsov, Sergey P.

    2011-12-01

    An electronic device is suggested representing a non-autonomous dynamical system with hyperbolic chaotic attractor of Plykin type in the stroboscopic map, and the results of its simulation with software package NI MULTISIM are considered in comparison with numerical integration of the underlying differential equations. A main practical advantage of electronic devices of this kind is their structural stability that means insensitivity of the chaotic dynamics in respect to variations of functions and parameters of elements constituting the system as well as to interferences and noises.

  11. Turbine protecting device in a BWR type nuclear power plant

    International Nuclear Information System (INIS)

    Kasuga, Hajime; Oka, Yoko.

    1984-01-01

    Purpose: To prevent highly humid steams from flowing into the turbine upon abnormal reduction in the reactor water level in order to ensure the turbine soundness, as well as in order to trip the turbine with no undesired effect on the reactor. Constitution: A protection device comprising a judging device and a timer are disposed in a BWR type reactor, in order to control a water level signal from a reactor water level gage. If the reactor water level is reduced during rated power operation, steams are kept to be generated due to decay heat although reactor is scramed. When a signal from the reactor water level detector is inputted to the protection device, a trip signal is outputted by way of a judging device after 15 second by means of the timer, when the main steam check valve is closed to trip the turbine. With this delay of time, abrupt increase in the pressure of the reactor due to sudden shutdown can be prevented. (Nakamoto, H)

  12. Interband cascade light emitting devices based on type-II quantum wells

    International Nuclear Information System (INIS)

    Yang, Rui Q.; Lin, C.H.; Murry, S.J.

    1997-01-01

    The authors discuss physical processes in the newly developed type-II interband cascade light emitting devices, and review their recent progress in the demonstration of the first type-II interband cascade lasers and the observation of interband cascade electroluminescence up to room temperature in a broad mid-infrared wavelength region (extended to 9 μm)

  13. 33 CFR 159.126 - Coliform test: Type II devices.

    Science.gov (United States)

    2010-07-01

    ... follows: During each of the 10 test days, one sample must be taken at the beginning, middle and end of an 8-consecutive hour period with one additional sample taken immediately following the peak capacity...: Type II devices. (a) The arithmetic mean of the fecal coliform bacteria in 38 of 40 samples of effluent...

  14. 33 CFR 159.123 - Coliform test: Type I devices.

    Science.gov (United States)

    2010-07-01

    ... as follows: During each of the 10-test days, one sample must be taken at the beginning, middle, and end of an 8-consecutive hour period with one additional sample taken immediately following the peak...: Type I devices. (a) The arithmetic mean of the fecal coliform bacteria in 38 of 40 samples of effluent...

  15. Track type ultrasonic inspection device

    International Nuclear Information System (INIS)

    Kajiyama, Shigeru; Sasaki, Tsukasa; Takahisa, Kazuo.

    1993-01-01

    The present invention concerns an improvement of a scanning device disposed near an object to be inspected such as a nuclear pressure vessel and having an ultrasonic probe, mounted thereon that travel along a running track. Specifically, one of wheel supports on both sides is attached being secured to the scanning device. The other of the supports is capable of fixing and releasing, as well as providing and releasing pressure to and from wheels upon mounting and detachment. This enables to provide a structure capable of pressing the wheels of the running device to the plane of the track and release thereof. Accordingly, it is possible to improve the running performance, reduce the size and weight and shorten the time for mounting and detachment of the running inspection device. (I.S.)

  16. Safety evaluation of stamp type digital microneedle devices in hairless mice.

    Science.gov (United States)

    Park, Kui Young; Jang, Woo Sun; Lim, Yun Young; Ahn, Joo Hee; Lee, Sang Jin; Kim, Chan Woong; Kim, Sung Eun; Kim, Beom Joon; Kim, Myeung Nam

    2013-02-01

    Microneedles provide a minimally invasive means to transport molecules into the skin. A number of specific strategies have been employed to use microneedles for transdermal delivery. The purpose of this study was to investigate the safety of two new digital microneedle devices (Digital Hand® and Digital Pro®; Bomtech Electronics Co., Ltd., Seoul, Korea) for the perforation of skin in skin-hairless-1 mice. This device replaces conventional needles and is designed specifically for intradermal delivery. We used two newly developed digital microneedle devices to perforate the skin of skin-hairless-1 mice. We conducted a comparative study of the two digital microneedle devices and DTS® (Disk type-microneedle Therapy System; DTS lab., Seoul, Korea). To evaluate skin stability, we performed visual and dermatoscopic inspections, measurements of transepidermal water loss, and biopsies. The two novel digital microneedle devices did not induce significant abnormalities of the skin on visual or dermatoscopic inspection, regardless of needle size (0.25~2.0 mm). No significant histopathological changes, such as inflammatory cell infiltration, desquamation of the stratum corneum, or disruption of the basal layer, were observed. The digital microneedle devices and microneedle therapy system produced similar results on measures of skin stability. These two novel digital microneedle devices are safe transdermal drug delivery systems.

  17. Availability and improvement of a vacuum-type immobilization device in pediatric CT

    International Nuclear Information System (INIS)

    Tani, Shoji; Mizuno, Naoto; Abe, Syuji

    2002-01-01

    The essential factors for an immobilization device in pediatric CT are absence of artifacts, safety, no disturbance of the patient's sedation, and ease of handling. We evaluated the suitability of a commercially available vacuum-type immobilization device designed for radiation therapy (Vac-Lok) that meets these requisites. There were no artifacts in scans of the water phantom. The device easily immobilized the patient, was quick to release, and was superior to previous immobilization systems, according to replies to a questionnaire administered to physicians, technologists, and nurses. Schedule delays were reduced by using this device to examine sedated patients (up to 1 year of age). Despite these advantages, the device was too small to immobilize both extremities together when examining older patients. In order to overcome this problem, we invented a special immobilization device for pediatric CT. The new device could be applied to taller patients, up to 85 cm in height (the average height of 2-year-old infants), and was able to contribute to efficient utilization of the examination room. (author)

  18. Hydrogen injection device in BWR type reactor

    International Nuclear Information System (INIS)

    Takagi, Jun-ichi; Kubo, Koji.

    1988-01-01

    Purpose: To reduce the increasing ratio of main steam system dose rate due to N-16 activity due to excess hydrogen injection in the hydrogen injection operation of BWR type reactors. Constitution: There are provided a hydrogen injection mechanism for injecting hydrogen into primary coolants of a BWR type reactor, and a chemical injection device for injecting chemicals such as methanol, which makes nitrogen radioisotopes resulted in the reactor water upon hydrogen injection non-volatile, into the pressure vessel separately from hydrogen. Injected hydrogen and the chemicals are not reacted in the feedwater system, but the reaction proceeds due to the presence of radioactive rays after the injection into the pressure vessel. Then, hydrogen causes re-combination in the downcomer portion to reduce the dissolved oxygen concentration. Meanwhile, about 70 % of the chemicals is supplied by means of a jet pump directly to the reactor core, thereby converting the chemical form of N-16 in the reactor core more oxidative (non-volatile). (Kawakami, Y.)

  19. Development of a doorframe-typed swinging seedling pick-up device for automatic field transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Han, H.; Mao, H.; Hu, J.; Tian, K.

    2015-07-01

    A doorframe-typed swing seedling pick-up device for automatic field transplanters was developed and evaluated in a laboratory. The device, consisting of a path manipulator and two grippers, can move the pins slowly to extract seedlings from the tray cells and return quickly to the pick-up point for the next extraction. The path manipulator was constructed with the creative design of type-Ⅱ mechanism combination in series. It consists of an oscillating guide linkage mechanism and a grooved globoidal cam mechanism. The gripper is a pincette-type mechanism using the pick-up pins to penetrate into the root mass for seedling extraction. The dynamic analysis of the designed seedling pick-up device was simulated with ADAMS software. Being the first prototype, various performance tests under local production conditions were conducted to find out the optimal machine operation parameters and transplant production conditions. As the gripper with multiple fine pins was moved by the swing pick-up device, it can effectively complete the transplanting work cycle of extracting, transferring, and discharging a seedling. The laboratory evaluation showed that the pick-up device equipped with two grippers can extract 80 seedlings/min with a 90% success and a 3% failure in discharging seedlings, using 42-day-old tomato plantlets. The quality of extracting seedlings was satisfactory. (Author)

  20. The optimal number, type and location of devices in automation of electrical distribution networks

    Directory of Open Access Journals (Sweden)

    Popović Željko N.

    2015-01-01

    Full Text Available This paper presents the mixed integer linear programming based model for determining optimal number, type and location of remotely controlled and supervised devices in distribution networks in the presence of distributed generators. The proposed model takes into consideration a number of different devices simultaneously (remotely controlled circuit breakers/reclosers, sectionalizing switches, remotely supervised and local fault passage indicators along with the following: expected outage cost to consumers and producers due to momentary and long-term interruptions, automated device expenses (capital investment, installation, and annual operation and maintenance costs, number and expenses of crews involved in the isolation and restoration process. Furthermore, the other possible benefits of each of automated device are also taken into account (e.g., benefits due to decreasing the cost of switching operations in normal conditions. The obtained numerical results emphasize the importance of consideration of different types of automation devices simultaneously. They also show that the proposed approach have a potential to improve the process of determining of the best automation strategy in real life distribution networks.

  1. Intracranial pressure monitoring in severe blunt head trauma: does the type of monitoring device matter?

    Science.gov (United States)

    Aiolfi, Alberto; Khor, Desmond; Cho, Jayun; Benjamin, Elizabeth; Inaba, Kenji; Demetriades, Demetrios

    2018-03-01

    OBJECTIVE Intracranial pressure (ICP) monitoring has become the standard of care in the management of severe head trauma. Intraventricular devices (IVDs) and intraparenchymal devices (IPDs) are the 2 most commonly used techniques for ICP monitoring. Despite the widespread use of these devices, very few studies have investigated the effect of device type on outcomes. The purpose of the present study was to compare outcomes between 2 types of ICP monitoring devices in patients with isolated severe blunt head trauma. METHODS This retrospective observational study was based on the American College of Surgeons Trauma Quality Improvement Program database, which was searched for all patients with isolated severe blunt head injury who had an ICP monitor placed in the 2-year period from 2013 to 2014. Extracted variables included demographics, comorbidities, mechanisms of injury, head injury specifics (epidural, subdural, subarachnoid, intracranial hemorrhage, and diffuse axonal injury), Abbreviated Injury Scale (AIS) score for each body area, Injury Severity Score (ISS), vital signs in the emergency department, and craniectomy. Outcomes included 30-day mortality, complications, number of ventilation days, intensive care unit and hospital lengths of stay, and functional independence. RESULTS During the study period, 105,721 patients had isolated severe traumatic brain injury (head AIS score ≥ 3). Overall, an ICP monitoring device was placed in 2562 patients (2.4%): 1358 (53%) had an IVD and 1204 (47%) had an IPD. The severity of the head AIS score did not affect the type of ICP monitoring selected. There was no difference in the median ISS; ISS > 15; head AIS Score 3, 4, or 5; or the need for craniectomy between the 2 device groups. Unadjusted 30-day mortality was significantly higher in the group with IVDs (29% vs 25.5%, p = 0.046); however, stepwise logistic regression analysis showed that the type of ICP monitoring was not an independent risk factor for death

  2. A new DRAM-type memory devices based on polymethacrylate containing pendant 2-methylbenzothiazole

    International Nuclear Information System (INIS)

    Wang Dong; Li Hua; Li Najun; Zhao Ying; Zhou Qianhao; Xu Qingfeng; Lu Jianmei; Wang Lihua

    2012-01-01

    Graphical abstract: The devices fabricated with 75 nm and 45 nm thick pBVMA films were both found to exhibit DRAM type memory behaviors, which may indicate that the Al nanoparticles had no penetration into the thin film during the vacuum-deposition process. Highlights: ► The side-functional moieties of pBVMA regularly arranged in film state. ► The device exhibits volatile memory behavior with an ON/OFF current ratio up to 10 5 . ► The film thickness has nothing to do with the device's memory behavior. ► Physical theoretical models and molecular simulation supported the memory mechanism. - Abstract: A polymethacrylate containing pendant 2-methylbenzothiazole (pBVMA) with good thermal stability was synthesized by free radical polymerization. The devices based on pBVMA possess a sandwich structure comprising bottom indium-tin oxide (ITO) electrode and top Al electrode. The as-fabricated device exhibits the dynamic random access memory (DRAM) behavior with an ON/OFF current ratio up to 10 5 and can endure 10 8 read cycles under −1 V pulse voltage. The effect of the film thickness on the device performance was investigated and the devices fabricated with 75 nm and 45 nm thick pBVMA films were both found to exhibit DRAM type memory behaviors, which may indicate that the Al nanoparticles had no penetration into the thin film during the vacuum-deposition process. The molecular simulation and physical theoretical models were analyzed and the mechanism of the DRAM performance may be attributed to the weak electron withdrawing ability of the molecule.

  3. Type synthesis and preliminary design of devices supporting lower limb's rehabilitation.

    Science.gov (United States)

    Olinski, Michał; Lewandowski, Bogusz; Gronowicz, Antoni

    2015-01-01

    Based on the analysis of existing solutions, biomechanics of human lower limbs and anticipated applications, results of con- siderations concerning the necessary number of degrees of freedom for the designed device supporting rehabilitation of lower extremities are presented. An analysis was carried out in order to determine the innovative kinematic structure of the device, ensuring sufficient mobility and functionality while minimizing the number of degrees of freedom. With the aid of appropriate formalised meth- ods, for instance, type synthesis, a complete variety of solutions for leg joints were obtained in the form of basic and kinematic schemes, having the potential to find application in devices supporting lower limb rehabilitation. A 3D model of ankle joint module was built in Autodesk Inventor System, then imported to Adams and assembled into a moving numerical model of a mechanism. Several conducted simulations resulted in finding the required maximum stroke of the cylinders. A comparison of the angular ranges of ankle joint and similar devices with the ones achieved by the designed device indicated a sufficient reserve allowing not only movements typical of gait, but approximately achieving the passive range of motion for the ankle joint.

  4. High voltage semiconductor devices and methods of making the devices

    Energy Technology Data Exchange (ETDEWEB)

    Matocha, Kevin; Chatty, Kiran; Banerjee, Sujit

    2018-01-23

    A multi-cell MOSFET device including a MOSFET cell with an integrated Schottky diode is provided. The MOSFET includes n-type source regions formed in p-type well regions which are formed in an n-type drift layer. A p-type body contact region is formed on the periphery of the MOSFET. The source metallization of the device forms a Schottky contact with an n-type semiconductor region adjacent the p-type body contact region of the device. Vias can be formed through a dielectric material covering the source ohmic contacts and/or Schottky region of the device and the source metallization can be formed in the vias. The n-type semiconductor region forming the Schottky contact and/or the n-type source regions can be a single continuous region or a plurality of discontinuous regions alternating with discontinuous p-type body contact regions. The device can be a SiC device. Methods of making the device are also provided.

  5. On-chip concentration of bacteria using a 3D dielectrophoretic chip and subsequent laser-based DNA extraction in the same chip

    International Nuclear Information System (INIS)

    Cho, Yoon-Kyoung; Kim, Tae-hyeong; Lee, Jeong-Gun

    2010-01-01

    We report the on-chip concentration of bacteria using a dielectrophoretic (DEP) chip with 3D electrodes and subsequent laser-based DNA extraction in the same chip. The DEP chip has a set of interdigitated Au post electrodes with 50 µm height to generate a network of non-uniform electric fields for the efficient trapping by DEP. The metal post array was fabricated by photolithography and subsequent Ni and Au electroplating. Three model bacteria samples (Escherichia coli, Staphylococcus epidermidis, Streptococcus mutans) were tested and over 80-fold concentrations were achieved within 2 min. Subsequently, on-chip DNA extraction from the concentrated bacteria in the 3D DEP chip was performed by laser irradiation using the laser-irradiated magnetic bead system (LIMBS) in the same chip. The extracted DNA was analyzed with silicon chip-based real-time polymerase chain reaction (PCR). The total process of on-chip bacteria concentration and the subsequent DNA extraction can be completed within 10 min including the manual operation time.

  6. Analysis of Contemporary Methods for Designing Rotary Type Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    E. P. Banin

    2015-01-01

    Full Text Available The research object is inlet apparatus of ventricular assist device, namely inlet cannula and straightener.The purpose of the study is to reveal features of blood flow in inlet apparatus of ventricular assist device. The mathematical modeling is carried out by computational fluid dynamics analysis in a stationary setting.The first part of study concerns the analysis of existing approaches to the numerical and experimental studies in designing the ventricular assist devices of rotary type. It reveals the features of each approach for their further application in practice. The article presents an original design of developed hydraulic test bench to verify the results of mathematical modeling. Analysis of foreign authors’ studies showed that there is no enough attention paid to design of the adjacent pump assemblies of ventricular assist device. The second part of study considers direct mathematical modeling of input apparatus of ventricular assist device. The study examined straightener with three or four blades. Mathematical modeling has revealed the presence of potentially dangerous stagnation zones and essential asymmetry of the outlet flow from the input unit. The found features must be taken in consideration in designing the ventricular assist device pumps. In the future we plan to use obtained data to create a parametric model of the rotor and the diffuser considering the abovementioned features.

  7. The digital radiographic and computed tomography imaging of two types of explosive devices

    International Nuclear Information System (INIS)

    Galiano Riveros, Eduardo

    2002-01-01

    Two well-established medical imaging methods, digital radiography (DR) and computed tomography (CT), were employed to obtain images of two types of explosive devices, model rocket engines and shotgun shells. The images were evaluated from an airport security perspective. In terms of geometrical shape, the detection probability of the explosive devices appears to be higher with DR imaging, but in terms of the actual explosive compounds in the devices, CT appears to offer a higher detection probability. DR imaging offers a low detection probability for the explosive powder in the shotgun shells, but a rather significant detection probability for the explosive propellant in the model rocket engines

  8. Dynamic Actuation of Single-Crystal Diamond Nanobeams

    OpenAIRE

    Sohn, Young-Ik; Burek, Michael J.; Kara, Vural; Kearns, Ryan; Lončar, Marko

    2014-01-01

    We show the dielectrophoretic actuation of single-crystal diamond nanomechanical devices. Gradient radio-frequency electromagnetic forces are used to achieve actuation of both cantilever and doubly clamped beam structures, with operation frequencies ranging from a few MHz to ~50MHz. Frequency tuning and parametric actuation are also studied.

  9. Modeling and characterization of dielectrophoretically structured piezoelectric composites using piezoceramic particle inclusions with high aspect ratios

    Science.gov (United States)

    van den Ende, D. A.; Maier, R. A.; van Neer, P. L. M. J.; van der Zwaag, S.; Randall, C. A.; Groen, W. A.

    2013-01-01

    In this work, the piezoelectric properties at high electric fields of dielectrophoretically aligned PZT—polymer composites containing high aspect ratio particles (such as short fibers) are presented. Polarization and strain as a function of electric field are evaluated. The properties of the composites are compared to those of PZT-polymer composites with equiaxed particles, continuous PZT fiber-polymer composites, and bulk PZT ceramics. From high-field polarization and strain measurements, the effective field dependent permittivity and piezoelectric charge constant in the poling direction are determined for dielectrophoresis structured PZT-polymer composites, continuous PZT fiber-polymer composites, and bulk PZT ceramics. The changes in dielectric properties of the inclusions and the matrix at high fields influence the dielectric and piezoelectric properties of the composites. It is found that the permittivity and piezoelectric charge constants increase towards a maximum at an applied field of around 2.5-5 kV/mm. The electric field at which the maximum occurs depends on the aspect ratio and degree of alignment of the inclusions. Experimental values of d33 at low and high applied fields are compared to a model describing the composites as a continuous polymer matrix containing PZT particles of various aspect ratios arranged into chains. Thickness mode coupling factors were determined from measured impedance data using fitted equivalent circuit model simulations. The relatively high piezoelectric strain constants, voltage constants, and thickness coupling factors indicate that such aligned short fiber composites could be useful as flexible large area transducers.

  10. A newly developed oval-shaped port device (E•Z ACCESS Oval type) for use in reduced port surgery: initial clinical experiences with cholecystectomy.

    Science.gov (United States)

    Shibao, Kazunori; Takagi, Tsuyoshi; Higure, Aiichiro; Yamaguchi, Koji

    2013-09-01

    We recently developed an oval-shaped E•Z Access device designed exclusively for use with the LAP PROTECTOR™ Oval type device (Hakko Co. Ltd., Tokyo, Japan). The transverse abdominal opening diameter made by round-shaped (Alexis® Wound Retractor, Applied Medical, Rancho Santa Margarita, CA; and LAP PROTECTOR™ Round type) and oval-shaped (LAP PROTECTOR™ Oval type) wound retractors was measured and compared in 5 patients with cholecystolithiasis. Each device was placed through a single 25-mm longitudinal umbilical incision, and the length of trocar separation was compared. LESS cholecystectomy was then performed using the oval-shaped E•Z ACCESS/LAP PROTECTOR™. The transverse abdominal opening diameter was maximized with the LAP PROTECTOR™ Oval type device. The average distance between the working-ports for the glove method, round-shaped, and oval-shaped E•Z ACCESS/LAP PROTECTOR™ devices in the 25-mm umbilical incisions were 20 ± 0.8 mm, 24 ± 1.5 mm, and 35 ± 0.8 mm, respectively. Wider trocar separation was achieved using the oval-shaped device, making the surgical procedures easier to perform. No perioperative port-related or surgical complications were observed. LESS cholecystectomy using the E•Z ACCESS Oval type device was found to be technically feasible. The Oval type device appears to allow for wider trocar separation, thereby reducing stress on the surgeon, ensuring patient safety, and providing cosmetic benefits.

  11. A video-amplifier device for the transmission-type electron microscope ELMISCOP I of Siemens

    International Nuclear Information System (INIS)

    Groboth, G.; Hoerl, E.M.

    1975-01-01

    In order to get a visual image of the sample at the final screen of a transmission-type electron microscope and to keep at the same time the sample at low temperature a video-amplifier device has been developed by the authors. Details about its design and the necessary reconstruction of the electron microscope equipment are given. The beam current density at the transparent screen is reduced to 10 -12 -10 -13 A.cm -2 . Moreover the costs of this video-amplifier device are lower than those available. (CR)

  12. Record mobility in transparent p-type tin monoxide films and devices by phase engineering

    KAUST Repository

    Caraveo-Frescas, Jesus Alfonso

    2013-06-25

    Here, we report the fabrication of nanoscale (15 nm) fully transparent p-type SnO thin film transistors (TFT) at temperatures as low as 180 C with record device performance. Specifically, by carefully controlling the process conditions, we have developed SnO thin films with a Hall mobility of 18.71 cm2 V-1 s-1 and fabricated TFT devices with a linear field-effect mobility of 6.75 cm2 V-1 s -1 and 5.87 cm2 V-1 s-1 on transparent rigid and translucent flexible substrates, respectively. These values of mobility are the highest reported to date for any p-type oxide processed at this low temperature. We further demonstrate that this high mobility is realized by careful phase engineering. Specifically, we show that phase-pure SnO is not necessarily the highest mobility phase; instead, well-controlled amounts of residual metallic tin are shown to substantially increase the hole mobility. A detailed phase stability map for physical vapor deposition of nanoscale SnO is constructed for the first time for this p-type oxide. © 2013 American Chemical Society.

  13. Heat resistant/radiation resistant cable and incore structure test device for FBR type reactor

    International Nuclear Information System (INIS)

    Tanimoto, Hajime; Shiono, Takeo; Sato, Yoshimi; Ito, Kazumi; Sudo, Shigeaki; Saito, Shin-ichi; Mitsui, Hisayasu.

    1995-01-01

    A heat resistant/radiation resistant coaxial cable of the present invention comprises an insulation layer, an outer conductor and a protection cover in this order on an inner conductor, in which the insulation layer comprises thermoplastic polyimide. In the same manner, a heat resistant/radiation resistant power cable has an insulation layer comprising thermoplastic polyimide on a conductor, and is provided with a protection cover comprising braid of alamide fibers at the outer circumference of the insulation layer. An incore structure test device for an FBR type reactor comprises the heat resistant/radiation resistant coaxial cable and/or the power cable. The thermoplastic polyimide can be extrusion molded, and has excellent radiation resistant by the extrusion, as well as has high dielectric withstand voltage, good flexibility and electric characteristics at high temperature. The incore structure test device for the FBR type reactor of the present invention comprising such a cable has excellent reliability and durability. (T.M.)

  14. A novel needle-type sampling device for flexible ultrathin bronchoscopy

    International Nuclear Information System (INIS)

    Suda, Yuji; Hayashi, Katsutoshi; Shindoh, Yuriko; Iijima, Hideya; Tanaka, Akiko

    2008-01-01

    Diagnosis of suspected cancer in the periphery of the lung is difficult. A flexible ultrathin bronchoscope has been developed for the diagnosis of peripherally located pulmonary lesions that cannot be reached with the sampling devices for standard flexible bronchoscopes. The diagnostic yield with forceps and a brush for ultrathin bronchoscopes, however, is not adequate, especially when a lesion is not exposed to the bronchial lumen. We have thus developed a novel needle-type sampling device and tested its yield in transbronchial cytology. The device consists of an elongated dental H-file (0.4 mm in diameter and 110 cm in length), a housing sheath (1.0 mm in outer diameter), and a novel handle, which enables rapid out-and-in motion of the needle. Ten consecutive patients with a peripheral pulmonary lesion who had an indication for diagnostic procedure with a flexible ultrathin bronchoscope were enrolled. The optimal bronchial route to the lesion was analyzed with virtual bronchoscopy in a data set obtained with high-resolution computed tomography, and a novel bronchial route labeling system (prior-ridge-based relative orientation nomenclature) was employed to guide insertion of the bronchoscope. Sampling with the novel needle was performed prior to use of the forceps and brush under conventional fluoroscopy. In all the cases, sampling with the needle was successful and the amount of the specimen was sufficient for cytology. Our novel sampling system with flexible ultrathin bronchoscopes may contribute to accurate and minimally invasive diagnosis of peripheral pulmonary lesions. (author)

  15. Hybrid immersed interface-immersed boundary methods for AC dielectrophoresis

    International Nuclear Information System (INIS)

    Hossan, Mohammad Robiul; Dillon, Robert; Dutta, Prashanta

    2014-01-01

    Dielectrophoresis, a nonlinear electrokinetic transport mechanism, has become popular in many engineering applications including manipulation, characterization and actuation of biomaterials, particles and biological cells. In this paper, we present a hybrid immersed interface–immersed boundary method to study AC dielectrophoresis where an algorithm is developed to solve the complex Poisson equation using a real variable formulation. An immersed interface method is employed to obtain the AC electric field in a fluid media with suspended particles and an immersed boundary method is used for the fluid equations and particle transport. The convergence of the proposed algorithm as well as validation of the hybrid scheme with experimental results is presented. In this paper, the Maxwell stress tensor is used to calculate the dielectrophoretic force acting on particles by considering the physical effect of particles in the computational domain. Thus, this study eliminates the approximations used in point dipole methods for calculating dielectrophoretic force. A comparative study between Maxwell stress tensor and point dipole methods for computing dielectrophoretic forces are presented. The hybrid method is used to investigate the physics of dielectrophoresis in microfluidic devices using an AC electric field. The numerical results show that with proper design and appropriate selection of applied potential and frequency, global electric field minima can be obtained to facilitate multiple particle trapping by exploiting the mechanism of negative dielectrophoresis. Our numerical results also show that electrically neutral particles form a chain parallel to the applied electric field irrespective of their initial orientation when an AC electric field is applied. This proposed hybrid numerical scheme will help to better understand dielectrophoresis and to design and optimize microfluidic devices

  16. Studies of the Hard X-ray Emission from the Filippov Type Plasma Focus Device, Dena

    Science.gov (United States)

    Tafreshi, M. A.; Saeedzadeh, E.

    2006-12-01

    This article is about the characteristics of the hard X-ray (HXR) emission from the Filippov type plasma focus (PF) device, Dena. The article begins with a brief presentation of Dena, and the mechanism of the HXR production in PF devices. Then using the differential absorption spectrometry, the energy resolved spectrum of the HXR emission from a 37 kJ discharge in Dena, is estimated. The energy flux density and the energy fluence of this emission have also been calculated to be 1.9 kJ cm-2 s-1 and 9.4 × 10-5 J cm-2. In the end, after presentation of radiography of sheep bones and calf ribs, the medical application of the PF devices has been discussed.

  17. Fusion devices

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1977-01-01

    Three types of thermonuclear fusion devices currently under development are reviewed for an electric utilities management audience. Overall design features of laser fusion, tokamak, and magnetic mirror type reactors are described and illustrated. Thrusts and trends in current research on these devices that promise to improve performance are briefly reviewed. Twenty photographs and drawings are included

  18. Substrate type < 111 >-Cu{sub 2}O/<0001 >-ZnO photovoltaic device prepared by photo-assisted electrodeposition

    Energy Technology Data Exchange (ETDEWEB)

    Zamzuri, Mohd, E-mail: zamzuri@tf.me.tut.ac.jp [Department of Mechanical Eng., Toyohashi University of Technology, 1-1 Hibari Gaoka, Tempaku, Toyohashi, Aichi 441-8580 (Japan); School of Manufacturing Eng., Universiti Malaysia Perlis, Kampus Tetap Pauh Putra, Jln Arau-Changlun, 02600 Arau, Perlis (Malaysia); Sasano, Junji [Department of Mechanical Eng., Toyohashi University of Technology, 1-1 Hibari Gaoka, Tempaku, Toyohashi, Aichi 441-8580 (Japan); Mohamad, Fariza Binti [Faculty of Electrical & Electronic Eng., University Tun Hussein Onn Malaysia, 86400, Parit Raja, Batu Pahat, Johor (Malaysia); Izaki, Masanobu [Department of Mechanical Eng., Toyohashi University of Technology, 1-1 Hibari Gaoka, Tempaku, Toyohashi, Aichi 441-8580 (Japan)

    2015-11-30

    The substrate-type < 0001 > ZnO/<111 > Cu{sub 2}O photovoltaic (PV) device has been constructed by electrodeposition of a < 111 >-p-Cu{sub 2}O layer on an Au(111)/Si wafer substrate followed by stacking the n-ZnO layer by electrodeposition during light irradiation in aqueous solutions. The PV device was fabricated by stacking the Al:ZnO-window by sputtering and the top Al electrode by vacuum evaporation. The < 0001 >-ZnO layer was composed of aggregates of hexagonal columnar grains grown in the direction normal to the surface, and pores could be observed between the ZnO grains at the deposition time last 1800 s. The < 0001 >-ZnO/<111 >-Cu{sub 2}O PV device showed a photovoltaic performance under AM1.5 illumination, and showed the improved short-circuit current density of 5.87 mA cm{sup −2} by stacking the AZO-TCO due to the increase in the diffusion length of the carrier. - Highlights: • Substrate type ZnO/Cu{sub 2}O photovoltaic devices only by electrodeposition • ZnO layer was stacked on the Cu{sub 2}O layer by photo-assisted electrodeposition. • AZO/ZnO/Cu{sub 2}O photovoltaic devices with a short-circuit current density of 5.87 mA cm{sup −2}.

  19. Helical type thermonuclear device and control method

    International Nuclear Information System (INIS)

    Ishigaki, Yukio.

    1990-01-01

    In a conventional helical type thermonuclear device, electric current flows in the toroidal direction under magnetic fields of helical coils and vertical magnetic coils, by which a circulating electric field is caused. Therefore, there is a problem that electrons as a seed are generated by cosmic rays, etc., the electrons are confined in a magnetic field boundary, are accelerated by the circulating electric field, to reach a high energy level, collide against structures in a vacuum vessel and emit a great amount of X-rays. Then, compensation coils for offsetting the magnetic fields generated upon energization and deenergization of the vertical magnetic coils and the power source therefor are disposed at the positions opposing to each other on both sides of the vertical magnetic coils for controlling the variation coefficient rate of electric current upon energization and deenergization of the vertical magnetic coils. Since the compensation coils also offset the magnetic field generated upon energization and deenergization of the vertical magnetic field coils by this control, the circulating magnetic field is not caused in the vacuum vessel to reduce the X-ray radiation by electrons at high energy level. (N.H.)

  20. Does the type of access device influence the online buying behavior? : An explorative study

    NARCIS (Netherlands)

    Constantinides, Efthymios; de Weerd-Nederhof, Petronella C.; de Vries, Sjoerd A.; Fabian, Nicolai

    2018-01-01

    The purpose of this study is to assess whether the device type (smartphone, tablet or desktop) used to access an online shop, has any effect on the customer’s buying behavior and interaction with the site. A field experiment was conducted on the web site of an online retailer, collecting data with

  1. Design and prototyping of a wristband-type wireless photoplethysmographic device for heart rate variability signal analysis.

    Science.gov (United States)

    Ghamari, M; Soltanpur, C; Cabrera, S; Romero, R; Martinek, R; Nazeran, H

    2016-08-01

    Heart Rate Variability (HRV) signal analysis provides a quantitative marker of the Autonomic Nervous System (ANS) function. A wristband-type wireless photoplethysmographic (PPG) device was custom-designed to collect and analyze the arterial pulse in the wrist. The proposed device is comprised of an optical sensor to monitor arterial pulse, a signal conditioning unit to filter and amplify the analog PPG signal, a microcontroller to digitize the analog PPG signal, and a Bluetooth module to transfer the data to a smart device. This paper proposes a novel model to represent the PPG signal as the summation of two Gaussian functions. The paper concludes with a verification procedure for HRV signal analysis during sedentary activities.

  2. Internet-based Advertising Claims and Consumer Reasons for Using Electronic Cigarettes by Device Type in the US

    OpenAIRE

    Pulvers, K; Sun, JY; Zhuang, Y-L; Holguin, G; Zhu, S-H

    2017-01-01

    Objectives Important differences exist between closed-system and open-system e-cigarettes, but it is unknown whether online companies are marketing these devices differently and whether consumer reasons for using e-cigarettes vary by device type. This paper compares Internet-based advertising claims of closed- versus open-system products, and evaluates US consumers’ reasons for using closed- versus open-system e-cigarettes. Methods Internet sites selling exclusively closed (N = 130)...

  3. Positional Arrangements of Waste Exhaust Gas Ducts of C-Type Balanced Chimney Heating Devices on Building Façades

    Directory of Open Access Journals (Sweden)

    Erkan AVLAR

    2009-01-01

    Full Text Available In Turkey today, with the increase in availability of natural gas,detached heating devices are being preferred over existingheating devices. Due to the lack of chimneys in existing buildingsin Turkey or the presence of chimneys that fail to conformto standards, the use of C-type balanced chimney devices has increased.C-type balanced chimney devices take the combustionair directly from the outside by a specific air duct as detachedheating equipment, with enclosed combustion chambers anda specific waste gas exhaust duct, and they are ventilated independentlyof the field of equipment. Because of their essentiality,the use of a chimney is not required in these devices;the waste gas is exhausted through walls, windows, doors, orbalconies. The natural gas is a clean fossil fuel that requires nostorage in buildings and is easy to use. However, water vapor,carbon dioxide and nitrogen oxides are produced by the combustionof natural gas. It is widely known that high concentrationsof these products can have some adverse effects onhumans such as dizziness, headaches and nausea. As a result,the waste products could recoil through wall openings on thefaçade to create unhealthy indoor environments that could bedangerous to human health. Therefore, the importance of standardsand regulations about the positional arrangements of thewaste gas exhaust ducts of C-type balanced chimney devices onbuilding façades is increasing. In this research, we analyze thestudies of the Institution of Turkish Standards, Chamber of MechanicalEngineers, gas distribution companies, municipalitiesand authorized firms and compare the criteria to determine thenecessary application method. According to our comparison ofthe references accessed, the criteria are not uniform.

  4. Leakage detecting method and device for water tight vessel of wet-type container apparatus

    International Nuclear Information System (INIS)

    Tanaka, Yoshimi.

    1995-01-01

    The present invention provides a method of and a device for detecting leakage of a water tight vessel of a wet-type container apparatus for containing a reactor pressure vessel while immersing it water in a reactor container. Namely, in the wet-type container apparatus, the periphery of the pressure vessel is coated with a heat insulation material and the periphery of the heat insulation material is coated with a water tight vessel. The water tight vessel is immersed under water in the reactor container. As a method of detecting leakage of the wet-type container apparatus, gases mixed with helium are supplied into the water tight vessel at a pressure higher than the inner pressure of the reactor container at a lowest position of the reactor pressure vessel. A water level in the reactor container is determined so as to form a space at the top portion of the inside of the reactor container. The helium at the top portion is detected to monitor the leakage of the water tight vessel. With such procedures, even if the water tight vessel is ruptured at any position, helium mixed to the gases is released to water in the reactor container and rise up to the top space and detected by a helium leakage detection device. (I.S.)

  5. Reinventing a p-type doping process for stable ZnO light emitting devices

    Science.gov (United States)

    Xie, Xiuhua; Li, Binghui; Zhang, Zhenzhong; Shen, Dezhen

    2018-06-01

    A tough challenge for zinc oxide (ZnO) as the ultraviolet optoelectronics materials is realizing the stable and reliable p-type conductivity. Self-compensation, coming from native donor-type point defects, is a big obstacle. In this work, we introduce a dynamic N doping process with molecular beam epitaxy, which is accomplished by a Zn, N-shutter periodic switch (a certain time shift between them for independent optimization of surface conditions). During the epitaxy, N adatoms are incorporated under the condition of (2  ×  2)  +  Zn vacancies reconstruction on a Zn-polar surface, at which oxygen vacancies (V O), the dominating compensating donors, are suppressed. With the p-ZnO with sufficient holes surviving, N concentration ~1  ×  1019 cm‑3, is employed in a p-i-n light emitting devices. Significant ultraviolet emission of electroluminescence spectra without broad green band (related to V O) at room-temperature are demonstrated. The devices work incessantly without intentional cooling for over 300 h at a luminous intensity reduction of one order of magnitude under the driving of a 10 mA continuous current, which are the demonstration for p-ZnO stability and reliability.

  6. EPICS GPIB device support

    International Nuclear Information System (INIS)

    Winans, J.

    1993-01-01

    A GPIB device support module is used to provide access to the operating parameters of a GPIB device. GPIB devices may be accessed via National Instruments 1014 cards or via Bitbus Universal Gateways. GPIB devices typically have many parameters, each of which may be thought of in terms of the standard types of database records available in EPICS. It is the job of the device support module designer to decide how the mapping of these parameters will be made to the available record types. Once this mapping is complete, the device support module may be written. The writing of the device support module consists primarily of the construction of a parameter table. This table is used to associate the database record types with the operating parameters of the GPIB instrument. Other aspects of module design include the handling of SRQ events and errors. SRQ events are made available to the device support module if so desired. The processing of an SRQ event is completely up to the designer of the module. They may be ignored, tied to event based record processing, or anything else the designer wishes. Error conditions may be handled in a similar fashion

  7. Transcatheter interruption of large residual flow after device closure of "Type A" patent ductus arteriosus

    Directory of Open Access Journals (Sweden)

    Anuradha Sridhar

    2012-01-01

    Full Text Available We report a case of 3-year-old girl who had persistence of large residual flow following transcatheter closure of a 6 mm ′Type A′ patent ductus arteriosus using a 12 × 10 mm duct occluder. Angiography revealed a large left-to-right shunt coursing through and exiting around the implanted device. Near total abolition of the residual shunt was achieved by initial implantation of an embolization coil within the duct occluder and subsequently an Amplatzer duct occluder (ADO II adjacent to the duct occluder. This challenging case describes an additional technique of abolishing a large residual flow in and around a Nitinol duct occluder device.

  8. Percutaneous closure of patent ductus arteriosus in children using amplatzer duct occluder II: relationship between PDA type and risk of device protrusion into the descending aorta.

    Science.gov (United States)

    Masri, Samer; El Rassi, Issam; Arabi, Mariam; Tabbakh, Anas; Bitar, Fadi

    2015-08-01

    To compare the efficacy and safety of Amplatzer Duct Occluder II (ADOII) among the various patent ductus arteriosus (PDA) types, and to assess the association between development of aortic obstruction and the PDA type in terms of measurable parameters as the device angulation and distance of upper end protrusion into the aortic lumen. Retrospective cohort study involving 50 consecutive subjects who underwent ADO II device closure of PDA. The median age and weight at intervention were 13 months (5.5 months to 18 years) and 11 (6-67) kg respectively. The median smallest ductal diameter by angiography was 3.2 (1.9-5.4) mm. Thirty two patients had type A PDA, 5 had type C, 5 had type D, and 8 had type E. Residual shunt was seen in only 1 patient who had a tubular PDA and resolved within 2 months of the procedure. No device embolization or pulmonary side protrusion were noted. There was a 16% aortic protrusion rate. The median distance of protrusion of the upper end of the device into the aortic lumen was 3.1 (0-9) mm and the median angle formed between the aortic end of the device and the PDA take-off was 10.4 (0-80.6) degrees. These latter parameters of aortic obstruction were significantly higher in the non-conical PDA group as compared to the conical PDA. Nevertheless, there was no significant coarctation due to aortic retention disc protrusion. Device closure of PDA using the ADO II is a safe procedure for chosen types of PDA. We demonstrated a novel technique for objective assessment of device protrusion into the descending aorta based on measurable parameters. ADOII device closure of non-conical PDAs warrants closer follow ups. © 2015 Wiley Periodicals, Inc.

  9. 75 FR 59611 - Microbiology Devices; Reclassification of Herpes Simplex Virus Types 1 and 2 Serological Assays...

    Science.gov (United States)

    2010-09-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2009-N-0344] Microbiology Devices; Reclassification of Herpes Simplex Virus Types 1 and 2 Serological Assays; Confirmation of Effective Date AGENCY: Food and Drug Administration, HHS. ACTION: Direct...

  10. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  11. Simultaneous control of thermoelectric properties in p- and n-type materials by electric double-layer gating: New design for thermoelectric device

    Science.gov (United States)

    Takayanagi, Ryohei; Fujii, Takenori; Asamitsu, Atsushi

    2015-05-01

    We report a novel design of a thermoelectric device that can control the thermoelectric properties of p- and n-type materials simultaneously by electric double-layer gating. Here, p-type Cu2O and n-type ZnO were used as the positive and negative electrodes of the electric double-layer capacitor structure. When a gate voltage was applied between the two electrodes, holes and electrons accumulated on the surfaces of Cu2O and ZnO, respectively. The thermopower was measured by applying a thermal gradient along the accumulated layer on the electrodes. We demonstrate here that the accumulated layers worked as a p-n pair of the thermoelectric device.

  12. Recommended safety procedures for the selection and use of demonstration-type gas discharge devices in schools

    International Nuclear Information System (INIS)

    1979-01-01

    A 1972 survey of 30 Ottawa secondary schools revealed a total of 347 actual or potential X-ray sources available in these schools. More than half of these sources were gas discharge tubes. Some gas discharge tubes, in particular the cold cathode type, can emit X-rays at significantly high levels. Unless such tubes are used carefully, and with regard for good radiation safety practices, they can result in exposures to students that are in excess of the maximum levels recommended by the International Commission on Radiological Protection. Several cases of the recommended dose being exceeded were found in the classes surveyed. This document has been prepared to assist science teachers and others using demonstration-type gas discharge devices to select and use such devices so as to present negligible risk to themselves and students. Useful information on safety procedures to be followed when performing demonstrations or experiments is included. (J.T.A.)

  13. Rail for inspection/maintenance device in TOKAMAK type container of a thermonuclear reactor

    International Nuclear Information System (INIS)

    Takahashi, Kenji.

    1996-01-01

    A circular rail divided into four arcuate parts for an inspection/maintenance device which runs in a TOKAMAK type container is disposed. Each of the divided rails is supported at the center of the outer surface rotatably by extendable rail supporting shafts. Each of the divided rail is constituted such that it can be contained between limiters disposed at the outer side of the TOKAMAK container when each of the rail support shafts is contracted. With such a constitution, each of the rail support shafts and arcuate rail is contracted and rotated from the outside of the TOKAMAK type container by an actuator. In order to form a circular rail, each of the rail support shafts is extended toward the center of the TOKAMAK type container, and then each of the arcuate rails is rotated into a horizontal state. Then, the joint portions of each of the arcuate rails are connected by using remote controllable locking rods. (I.S.)

  14. Multiplexed charge-locking device for large arrays of quantum devices

    Energy Technology Data Exchange (ETDEWEB)

    Puddy, R. K., E-mail: rkp27@cam.ac.uk; Smith, L. W; Chong, C. H.; Farrer, I.; Griffiths, J. P.; Ritchie, D. A.; Smith, C. G. [Cavendish Laboratory, University of Cambridge, Cambridge CB3 0HE (United Kingdom); Al-Taie, H.; Kelly, M. J. [Cavendish Laboratory, University of Cambridge, Cambridge CB3 0HE (United Kingdom); Centre for Advanced Photonics and Electronics, Electrical Engineering Division, Department of Engineering, 9 J. J. Thomson Avenue, University of Cambridge, Cambridge CB3 0FA (United Kingdom); Pepper, M. [Department of Electronic and Electrical Engineering, University College London, WC1E 7JE (United Kingdom)

    2015-10-05

    We present a method of forming and controlling large arrays of gate-defined quantum devices. The method uses an on-chip, multiplexed charge-locking system and helps to overcome the restraints imposed by the number of wires available in cryostat measurement systems. The device architecture that we describe here utilises a multiplexer-type scheme to lock charge onto gate electrodes. The design allows access to and control of gates whose total number exceeds that of the available electrical contacts and enables the formation, modulation and measurement of large arrays of quantum devices. We fabricate such devices on n-type GaAs/AlGaAs substrates and investigate the stability of the charge locked on to the gates. Proof-of-concept is shown by measurement of the Coulomb blockade peaks of a single quantum dot formed by a floating gate in the device. The floating gate is seen to drift by approximately one Coulomb oscillation per hour.

  15. Plasma membrane characterization, by scanning electron microscopy, of multipotent myoblasts-derived populations sorted using dielectrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Muratore, Massimo, E-mail: M.Muratore@ed.ac.uk [Institute of Integrated Micro and Nano System, School of Engineering, The University of Edinburgh, Edinburgh EH9 3JF (United Kingdom); Mitchell, Steve [Institute of Molecular Plant Science, School of Biological Science, The University of Edinburgh, Edinburgh EH9 3JF (United Kingdom); Waterfall, Martin [Institute of Immunology and Infection Research, School of Biological Science, The University of Edinburgh, Edinburgh EH9 3JT (United Kingdom)

    2013-09-06

    Highlights: •Dielectrophoretic separation/sorting of multipotent cells. •Plasma membrane microvilli structure of C2C12 and fibroblasts by SEM microscopy. •Cell cycle determination by Ki-67 in DEP-sorted cells. •Plasma membrane differences responsible for changes in membrane capacitance. -- Abstract: Multipotent progenitor cells have shown promise for use in biomedical applications and regenerative medicine. The implementation of such cells for clinical application requires a synchronized, phenotypically and/or genotypically, homogenous cell population. Here we have demonstrated the implementation of a biological tag-free dielectrophoretic device used for discrimination of multipotent myoblastic C2C12 model. The multipotent capabilities in differentiation, for these cells, diminishes with higher passage number, so for cultures above 70 passages only a small percentage of cells is able to differentiate into terminal myotubes. In this work we demonstrated that we could recover, above 96% purity, specific cell types from a mixed population of cells at high passage number without any biological tag using dielectrophoresis. The purity of the samples was confirmed by cytometric analysis using the cell specific marker embryonic myosin. To further investigate the dielectric properties of the cell plasma membrane we co-culture C2C12 with similar size, when in suspension, GFP-positive fibroblast as feeder layer. The level of separation between the cell types was above 98% purity which was confirmed by flow cytometry. These levels of separation are assumed to account for cell size and for the plasma membrane morphological differences between C2C12 and fibroblast unrelated to the stages of the cell cycle which was assessed by immunofluorescence staining. Plasma membrane conformational differences were further confirmed by scanning electron microscopy.

  16. Plasma membrane characterization, by scanning electron microscopy, of multipotent myoblasts-derived populations sorted using dielectrophoresis

    International Nuclear Information System (INIS)

    Muratore, Massimo; Mitchell, Steve; Waterfall, Martin

    2013-01-01

    Highlights: •Dielectrophoretic separation/sorting of multipotent cells. •Plasma membrane microvilli structure of C2C12 and fibroblasts by SEM microscopy. •Cell cycle determination by Ki-67 in DEP-sorted cells. •Plasma membrane differences responsible for changes in membrane capacitance. -- Abstract: Multipotent progenitor cells have shown promise for use in biomedical applications and regenerative medicine. The implementation of such cells for clinical application requires a synchronized, phenotypically and/or genotypically, homogenous cell population. Here we have demonstrated the implementation of a biological tag-free dielectrophoretic device used for discrimination of multipotent myoblastic C2C12 model. The multipotent capabilities in differentiation, for these cells, diminishes with higher passage number, so for cultures above 70 passages only a small percentage of cells is able to differentiate into terminal myotubes. In this work we demonstrated that we could recover, above 96% purity, specific cell types from a mixed population of cells at high passage number without any biological tag using dielectrophoresis. The purity of the samples was confirmed by cytometric analysis using the cell specific marker embryonic myosin. To further investigate the dielectric properties of the cell plasma membrane we co-culture C2C12 with similar size, when in suspension, GFP-positive fibroblast as feeder layer. The level of separation between the cell types was above 98% purity which was confirmed by flow cytometry. These levels of separation are assumed to account for cell size and for the plasma membrane morphological differences between C2C12 and fibroblast unrelated to the stages of the cell cycle which was assessed by immunofluorescence staining. Plasma membrane conformational differences were further confirmed by scanning electron microscopy

  17. Development of three dimensional seismic isolation device with laminated rubber bearing and rolling seal type air spring

    International Nuclear Information System (INIS)

    Okada, Yasuo; Suhara, Junji; Tamura, Tadashi; Ohta, Kazuya; Moro, Satoshi

    2003-01-01

    Three dimensional (3D) seismic isolation device has been developed to use for the base isolation system of the heavy building like a nuclear reactor building. The developed device is the 3D seismic isolation device that consists of the laminated rubber baring as a horizontal isolation device and the rolling seal type air spring as the vertical isolation device in series. In this research, the 3D seismic isolation device reduction model whose scale is 1/10 is made and the workability of the device by the horizontal and vertical dynamic load is examined. Two experiment parameters are considered. One is the case that the structure of the part that the horizontal load and the vertical load contact is pin condition and the other is the case of the roller condition. As a result of the examination, the workability of the vertical direction is confirmed when the horizontal load acts. The pressure resistant ability test for the air spring is performed by the monotonic pressurization. As the result, it is confirmed that pressure resistant ability improved by restricting the side deformation of the air spring and that the material of the existing air spring can withstand high pressure use sufficiently. As the result, it is confirmed that the developed 3D seismic isolation device is applicable to the actual plant. This study was performed under the sponsorship of the Ministry of Economy, Trade and Industry of Japan. (author)

  18. Ways of Telecommunications Interaction Arrangement for Microprocessor Devices of Different Types in Composition of Multi-Motor Electric Drives

    Science.gov (United States)

    Shpenst, V. A.; Vasiliev, B. Y.; Kalashnikov, O. V.; Oleynikova, A. M.

    2018-05-01

    The article covers a consideration of various state-of-the-art industrial data transfer protocols, e.g. Modbus, Profibus, Industrial Ethernet and CAN. Their pros and cons are analyzed and conclusions made on advisability of the use of each protocol. It is shown that for the arrangement of effective telecommunication interaction of microprocessor devices of different types in the composition of multi-motor electric drives, it is advisable to use highlevel CAN-protocols, such as CANopen and DeviceNet.

  19. Torus type thermonuclear device

    International Nuclear Information System (INIS)

    Imura, Yasuya.

    1979-01-01

    Purpose: To attain supporting effect against electromagnetic force and moderate the inner stress applied to toroidal coils due to thermal expansion by intervening a stress relaxation member between the outer circumferential side of a torus and a support device in toroidal coils. Constitution: Toroidal coils for confining a plasma within a torus vacuum container is supported on a support secured to upper and lower bases. A thermoplastic stress relaxation material of a low young's modulus is put between the outer circumferential side of the torus container and the torus outer circumferential side of the support in the toroidal coil. Thermoplastic resin is best suited to the stress relaxation substance, although tetrafluoro resin may be used as the stress relaxation substance while packing non-woven tetron fabric or non-woven glass fabric impregnated with varnish in a gap between the stress relaxation substance and the support or the toroidal coils. (Seki, T.)

  20. Separation of platelets from other blood cells in continuous-flow by dielectrophoresis field-flow-fractionation

    OpenAIRE

    Piacentini, Niccolò; Mernier, Guillaume; Tornay, Raphaël; Renaud, Philippe

    2011-01-01

    We present a microfluidic device capable of separating platelets from other blood cells in continuous flow using dielectrophoresis field-flow-fractionation. The use of hydrodynamic focusing in combination with the application of a dielectrophoretic force allows the separation of platelets from red blood cells due to their size difference. The theoretical cell trajectory has been calculated by numerical simulations of the electrical field and flow speed, and is in agreement with the experiment...

  1. Numerical analysis and experiment research on fluid orbital performance of vane type propellant management device

    International Nuclear Information System (INIS)

    Hu, Q; Li, Y; Pan, H L; Liu, J T; Zhuang, B T

    2015-01-01

    Vane type propellant management device (PMD) is one of the key components of the vane-type surface tension tank (STT), and its fluid orbital performance directly determines the STT's success or failure. In present paper, numerical analysis and microgravity experiment study on fluid orbital performance of a vane type PMD were carried out. By using two-phase flow model of volume of fluid (VOF), fluid flow characteristics in the tank with the vane type PMD were numerically calculated, and the rules of fluid transfer and distribution were gotten. A abbreviate model test system of the vane type PMD is established and microgravity drop tower tests were performed, then fluid management and transmission rules of the vane type PMD were obtained under microgravity environment. The analysis and tests results show that the vane type PMD has good and initiative fluid orbital management ability and meets the demands of fluid orbital extrusion in the vane type STT. The results offer valuable guidance for the design and optimization of the new generation of vane type PMD, and also provide a new approach for fluid management and control in space environment

  2. IMPROVING THE EFFICIENCY OF SPRAY TYPE DEVICES WHEN SOLVING PROBLEMS IN INDUSTRIAL ECOLOGY

    Directory of Open Access Journals (Sweden)

    S. Iu. Panov

    2014-01-01

    Full Text Available Summary. This carried out work is aimed enhancing the efficiency of the spray scrubber by combining processes and improving hydraulic conditions in the device. The problem of treating waste gases is often characterized by unique features and the significant factor that makes it difficult to find a solution to the problem of treatment is the low and/or variable concentration of the pollutant. With a removal efficiency of up to 98 %, wet treatment technology in scrubber type devices is the only practical method advantageous to the treatment of waste gases. The set objective is solved by developing a two-stage treatment system for pyrolysis gas based on ejector scrubbers. Their advantage - a central nozzle supply that allows the scrubber to operate on the principle of an ejector pump. A drift eliminator of the developed device is located on the case unit and a chain is suspended from a clamp mounted on the lower part of the tube neck by pins and two detachable joints. The operation of the scrubber was checked in compliance with the absorption gas treatment of sulfur dioxide. A chemical sorbent, calcium carbonate which is produced as a by-product in the manufacture of nitroammophos at JSC “Minudobrenia” factory is used. Preliminary results indicate that the stiochiometric inlet ratio of Ca/S equals about 2.0 and SO2 emissions reduce by 80-90 %, significantly larger than the planned 70 % and subsequently corresponds to the residue concentration of less than 30 mg/m3 . This is explained by the greater degree of capture and deposition of the sorbent on the chain curtain (not more than 20 mg/m3 . The proposed device for treating gases enables: improvement in the efficiency of gas treatment; increased reliability; increase in the degree of treatment of the gas flow without the use of additional equipment; reduction in metal and design complexity; reduction on the cost of the treatment process and simplification in the device design.

  3. An investigation of the plasma behaviour in a Filippov type plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Mahabadi, T D [Plasma Physics Research Center, I.A.U, PO Box 14665-678, Tehran (Iran, Islamic Republic of); Tafreshi, M A [School of Plasma Physics and Nuclear Fusion, Institute of Nuclear Science and Technology, AEOI, PO Box 14155-1339, Tehran (Iran, Islamic Republic of)

    2007-09-15

    Plasma behaviour in the 90 kJ Filippov type plasma focus (PF) device Dena, is studied both experimentally and theoretically. The latest experimental data obtained by the use of the Dena facility are presented. Then the experimental data are compared with the simulated data obtained through the ML model. This study shows that the ML model, to a good extent, is capable of predicting the plasma behaviour in the Filippov type PF. The experimental and the theoretical results show that the increment of the discharge voltage leads to an almost linear decrement of the pinch time. It is also shown that the increment of the pressure leads to a decrement of the current sheath expansion velocity. Finally, a semiempirical method for determination of the permitted values of the current efficiency factor and the mass shedding factor is presented.

  4. High current density M-type cathodes for vacuum electron devices

    International Nuclear Information System (INIS)

    Li Ji; Yu Zhiqiang; Shao Wensheng; Zhang Ke; Gao Yujuan; Yuan Haiqing; Wang Hui; Huang Kaizhi; Chen Qilue; Yan Suqiu; Cai Shaolun

    2005-01-01

    We investigated high current density emission capabilities of M-type cathodes used for vacuum electron devices (VEDs). The experimental results of emission and lifetime evaluating in both close-spaced diode structure and electron gun testing vehicles are given. Emission current densities measured in the diode structure at 1020 deg. C Br in the CW mode were above 10 A/cm 2 ; while in electron gun testing vehicles, emission current densities were above 8 A/cm 2 in CW mode and above 32 A/cm 2 in pulsed mode, respectively. The current density above 94 A/cm 2 has been acquired in no. 0306 electron gun vehicle while the practical temperature is 1060 deg. C Br . For a comparison some of the data from I-scandate cathodes are presented. Finally, several application examples in practical travelling wave tubes (TWTs) and multi beam klystrons (MBKs) are also reported

  5. Assessment of Sub-Micron Particles by Exploiting Charge Differences with Dielectrophoresis

    Directory of Open Access Journals (Sweden)

    Maria F. Romero-Creel

    2017-08-01

    Full Text Available The analysis, separation, and enrichment of submicron particles are critical steps in many applications, ranging from bio-sensing to disease diagnostics. Microfluidic electrokinetic techniques, such as dielectrophoresis (DEP have proved to be excellent platforms for assessment of submicron particles. DEP is the motion of polarizable particles under the presence of a non-uniform electric field. In this work, the polarization and dielectrophoretic behavior of polystyrene particles with diameters ranging for 100 nm to 1 μm were studied employing microchannels for insulator based DEP (iDEP and low frequency (<1000 Hz AC and DC electric potentials. In particular, the effects of particle surface charge, in terms of magnitude and type of functionalization, were examined. It was found that the magnitude of particle surface charge has a significant impact on the polarization and dielectrophoretic response of the particles, allowing for successful particle assessment. Traditionally, charge differences are exploited employing electrophoretic techniques and particle separation is achieved by differential migration. The present study demonstrates that differences in the particle’s surface charge can also be exploited by means of iDEP; and that distinct types of nanoparticles can be identified by their polarization and dielectrophoretic behavior. These findings open the possibility for iDEP to be employed as a technique for the analysis of submicron biological particles, where subtle differences in surface charge could allow for rapid particle identification and separation.

  6. Development and study of a control and reactor shutdown device for FBR-type reactors with a modified open core

    International Nuclear Information System (INIS)

    Goswami, S.

    1983-01-01

    The doctoral thesis at hand presents a newly designed control and shutdown device to be used for output control and fast shutdown of modified open core FBR-type reactors. The task was the design of a new control and shutdown device having economic and operation advantages, using reactor components time-tested under reactor conditions. This control and shutdown device was adapted to the specific needs concerning dimensions and design. The actuation is based on the magnetic-jack principle, which has been upgraded for the purpose. The principle is now combined with pneumatic acceleration. The improvements mainly concern a smaller number of piece parts and system simplification. (orig./RW) [de

  7. Bio-field array: a dielectrophoretic electromagnetic toroidal excitation to restore and maintain the golden ratio in human erythrocytes.

    Science.gov (United States)

    Purnell, Marcy C; Butawan, Matthew B A; Ramsey, Risa D

    2018-06-01

    Erythrocytes must maintain a biconcave discoid shape in order to efficiently deliver oxygen (O 2 ) molecules and to recycle carbon dioxide (CO 2 ) molecules. The erythrocyte is a small toroidal dielectrophoretic (DEP) electromagnetic field (EMF) driven cell that maintains its zeta potential (ζ) with a dielectric constant (ԑ) between a negatively charged plasma membrane surface and the positively charged adjacent Stern layer. Here, we propose that zeta potential is also driven by both ferroelectric influences (chloride ion) and ferromagnetic influences (serum iron driven). The Golden Ratio, a function of Phi φ, offers a geometrical mathematical measure within the distinct and desired curvature of the red blood cell that is governed by this zeta potential and is required for the efficient recycling of CO 2 in our bodies. The Bio-Field Array (BFA) shows potential to both drive/fuel the zeta potential and restore the Golden Ratio in human erythrocytes thereby leading to more efficient recycling of CO 2 . Live Blood Analyses and serum CO 2 levels from twenty human subjects that participated in immersion therapy sessions with the BFA for 2 weeks (six sessions) were analyzed. Live Blood Analyses (LBA) and serum blood analyses performed before and after the BFA immersion therapy sessions in the BFA pilot study participants showed reversal of erythrocyte rheological alterations (per RBC metric; P = 0.00000075), a morphological return to the Golden Ratio and a significant decrease in serum CO 2 (P = 0.017) in these participants. Immersion therapy sessions with the BFA show potential to modulate zeta potential, restore this newly defined Golden Ratio and reduce rheological alterations in human erythrocytes. © 2018 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  8. Electrical bistabilities and memory mechanisms of nonvolatile organic bistable devices based on exfoliated muscovite-type mica nanoparticle/poly(methylmethacrylate) nanocomposites

    Science.gov (United States)

    Lim, Won Gyu; Lee, Dea Uk; Na, Han Gil; Kim, Hyoun Woo; Kim, Tae Whan

    2018-02-01

    Organic bistable devices (OBDs) with exfoliated mica nanoparticles (NPs) embedded into an insulating poly(methylmethacrylate) (PMMA) layer were fabricated by using a spin-coating method. Current-voltage (I-V) curves for the Al/PMMA/exfoliated mica NP/PMMA/indium-tin-oxide/glass devices at 300 K showed a clockwise current hysteresis behavior due to the existence of the exfoliated muscovite-type mica NPs, which is an essential feature for bistable devices. Write-read-erase-read data showed that the OBDs had rewritable nonvolatile memories and an endurance number of ON/OFF switching for the OBDs of 102 cycles. An ON/OFF ratio of 1 × 103 was maintained for retention times larger than 1 × 104 s. The memory mechanisms of the fabricated OBDs were described by using the trapping and the tunneling processes within a PMMA active layer containing exfoliated muscovite-type mica NPs on the basis of the energy band diagram and the I-V curves.

  9. Supplymentary type semiconductor device and manufacturing method. Soho gata handotai sochi oyobi sono seizo hoho

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Masaaki

    1990-01-08

    As a supplementary type semiconductor device has a complicated structure, it is extremely difficult to construct it in a three dimensional structure. This invention aims to reduce its occupying area by forming p-channel and n-channel transistors in a solid structure; moreover in an easy method of production. In other words, an opening is made in the element-forming region of a semiconductor substrate, forming a gate-insulation film on each of the p-type and n-type semiconductors which are exposed on the two facing surfaces; on it formed a gate electrode; p-type semiconductor surface is used as a channel domain; a drain region of n-channel transistor on one surface and a source region on another surface; the n-type semiconductor surface corresponding to the gate electrode is used as a channel region; a source region of the n-channel transistor is formed on the same surface and the drain region on the substrate surface. Occupied area is thus made less and the production gets easier. 20 figs.

  10. Calculation device for fuel power history in BWR type reactors

    International Nuclear Information System (INIS)

    Sakagami, Masaharu.

    1980-01-01

    Purpose: To enable calculations for power history and various variants of power change in the power history of fuels in a BWR type reactor or the like. Constitution: The outputs of the process computation for the nuclear reactor by a process computer are stored and the reactor core power distribution is judged from the calculated values for the reactor core power distribution based on the stored data. Data such as for thermal power, core flow rate, control rod position and power distribution are recorded where the changes in the power distribution exceed a predetermined amount, and data such as for thermal power and core flow rate are recorded where the changes are within the level of the predetermined amount, as effective data excluding unnecessary data. Accordingly, the recorded data are taken out as required and the fuel power history and the various variants in the fuel power are calculated and determined in a calculation device for fuel power history and variants for fuel power fluctuation. (Furukawa, Y.)

  11. Numerical Study of an Ejector as an Expansion Device in Split-type Air Conditioners for Energy Savings

    Directory of Open Access Journals (Sweden)

    Kasni Sumeru

    2013-07-01

    Full Text Available The present study describes a numerical approach for determining both the motive nozzle and constant-area diameters of an ejector as an expansion device, based on the cooling capacity of a split-type air-conditioner using R290 as refrigerant. Previous studies have shown that replacement of HCFC R22 with HC290 (propane in the air conditioner can improve the coefficient of performance (COP. The purpose of replacing the capillary tube with an ejector as an expansion device in a split-type air conditioner using HC290 is to further improve the COP. In developing the model, conservation laws of mass, momentum and energy equations were applied to each part of the ejector. The numerical results show that the motive nozzle diameter remains constant (1.03 mm under varying condenser temperatures, whereas the diameter of the constant-area decreases as the condenser temperature increases. It was also found that improvement of the COP can reach 32.90% at a condenser temperature of 55 °C. From the results mentioned above, it can be concluded that the use of an ejector can further improve the COP of a split-type air conditioner using HC290 as working fluid.

  12. Continuous particle focusing in a waved microchannel using negative dc dielectrophoresis

    KAUST Repository

    Li, Ming

    2012-07-26

    We present a waved microchannel for continuous focusing of microparticles and cells using negative direct current (dc) dielectrophoresis. The waved channel is composed of consecutive s-shaped curved channels in series to generate an electric field gradient required for the dielectrophoretic effect. When particles move electrokinetically through the channel, the experienced negative dielectrophoretic forces alternate directions within two adjacent semicircular microchannels, leading to a focused continuous-flow stream along the channel centerline. Both the experimentally observed and numerically simulated results of the focusing performance are reported, which coincide acceptably in proportion to the specified dimensions (i.e. inlet and outlet of the waved channel). How the applied electric field, particle size and medium concentration affect the performance was studied by focusing polystyrene microparticles of varying sizes. As an application in the field of biology, the focusing of yeast cells in the waved mcirochannel was tested. This waved microchannel shows a great potential for microflow cytometry applications and is expected to be widely used before different processing steps in lab-on-A-chip devices with integrated functions. © 2012 IOP Publishing Ltd.

  13. Recoil transporter devices

    International Nuclear Information System (INIS)

    Madhavan, N.

    2005-01-01

    The study of sparsely produced nuclear reaction products in the direction of intense primary beam is a challenging task, the pursuit of which has given rise to the advent or several types of selective devices. These range from a simple parallel plate electrostatic deflector to state-of-the-art electromagnetic separators. There is no single device which can satisfy all the requirements of an ideal recoil transporter, simultaneously. An overview of such devices and their building blocks is presented, which may help in the proper choice of the device as per the experimental requirements. (author)

  14. Coaxial atomic force microscope probes for dielectrophoresis of DNA under different buffer conditions

    Science.gov (United States)

    Tao, Yinglei; Kumar Wickramasinghe, H.

    2017-02-01

    We demonstrate a coaxial AFM nanoprobe device for dielectrophoretic (DEP) trapping of DNA molecules in Tris-EDTA (TE) and phosphate-buffered saline (PBS) buffers. The DEP properties of 20 nm polystyrene beads were studied with coaxial probes in media with different conductivities. Due to the special geometry of our DEP probe device, sufficiently high electric fields were generated at the probe end to focus DNA molecules with positive DEP. DEP trapping for both polystyrene beads and DNA molecules was quantitatively analyzed over the frequency range from 100 kHz to 50 MHz and compared with the Clausius-Mossotti theory. Finally, we discussed the negative effect of medium salinity during DEP trapping.

  15. Multilayer mirror based monitors for impurity controls in large fusion reactor type devices

    International Nuclear Information System (INIS)

    Regan, S.P.; May, M.J.; Soukhanovskii, V.; Finkenthal, M.; Moos, H.W.

    1995-01-01

    Multilayer Mirror (MLM) based monitors are compact, high throughput diagnostics capable of extracting XUV emissions (the wavelength range including the soft-x-ray and the extreme ultraviolet, 10 angstrom to 304 angstrom) of impurities from the harsh environment of large fusion reactor type devices. For several years the Plasma Spectroscopy Group at Johns Hopkins University has investigated the application of MLM based XUV spectroscopic diagnostics for magnetically confined fusion plasmas. MLM based monitors have been constructed for and extensively used on DIII-D, Alcator C-mod, TEXT, Phaedrus-T, and CDX-U tokamaks to study the impurity behavior of elements ranging from He to Mo. On ITER MLM based devices would be used to monitor the spectral line emissions from Li I-like to F I-like charge states of Fe, Cr, and Ni, as well as extractors for the bands of emissions from high Z elements such as Mo or W for impurity controls of the fusion plasma. In addition to monitoring the impurity emissions from the main plasma, MLM based devices can also be adapted for radiation measurements of low Z elements in the divertor. The concepts and designs of these MLM based monitors for impurity controls in ITER will be presented. The results of neutron irradiation experiments of the MLMs performed in the Los Alamos Spallation Radiation Effects Facility (LASREF) at the Los Alamos National Laboratory will also be discussed. These preliminary neutron exposure studies show that the dispersive and reflective qualities of the MLMs were not affected in a significant manner

  16. 78 FR 15878 - Taxable Medical Devices; Correction

    Science.gov (United States)

    2013-03-13

    ...--MANUFATURERS AND RETAILERS EXCISE TAXES 0 Paragraph 1. The authority citation for part 48 continues to read in... device. * * * * * (b) * * * (2) * * * A device will be considered to be of a type that is generally..., the mobile x-ray systems are not devices that are of a type that are generally purchased by the...

  17. 78 FR 49272 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-08-13

    ... into two types: (1) Devices that provide automatic chest compressions at a fixed compression rate and... circuit is comprised of multiple device types, including, but not limited to, an oxygenator, blood pump... submit a brief statement of the general nature of the evidence or arguments they wish to present, the...

  18. An environment-adaptive management algorithm for hearing-support devices incorporating listening situation and noise type classifiers.

    Science.gov (United States)

    Yook, Sunhyun; Nam, Kyoung Won; Kim, Heepyung; Hong, Sung Hwa; Jang, Dong Pyo; Kim, In Young

    2015-04-01

    In order to provide more consistent sound intelligibility for the hearing-impaired person, regardless of environment, it is necessary to adjust the setting of the hearing-support (HS) device to accommodate various environmental circumstances. In this study, a fully automatic HS device management algorithm that can adapt to various environmental situations is proposed; it is composed of a listening-situation classifier, a noise-type classifier, an adaptive noise-reduction algorithm, and a management algorithm that can selectively turn on/off one or more of the three basic algorithms-beamforming, noise-reduction, and feedback cancellation-and can also adjust internal gains and parameters of the wide-dynamic-range compression (WDRC) and noise-reduction (NR) algorithms in accordance with variations in environmental situations. Experimental results demonstrated that the implemented algorithms can classify both listening situation and ambient noise type situations with high accuracies (92.8-96.4% and 90.9-99.4%, respectively), and the gains and parameters of the WDRC and NR algorithms were successfully adjusted according to variations in environmental situation. The average values of signal-to-noise ratio (SNR), frequency-weighted segmental SNR, Perceptual Evaluation of Speech Quality, and mean opinion test scores of 10 normal-hearing volunteers of the adaptive multiband spectral subtraction (MBSS) algorithm were improved by 1.74 dB, 2.11 dB, 0.49, and 0.68, respectively, compared to the conventional fixed-parameter MBSS algorithm. These results indicate that the proposed environment-adaptive management algorithm can be applied to HS devices to improve sound intelligibility for hearing-impaired individuals in various acoustic environments. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Graphene nanoribbons for electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Geng, Zhansong; Granzner, Ralf; Kittler, Mario; Schwierz, Frank [FG Festkoerperelektronik, Institut fuer Mikro- und Nanoelektronik und Institut fuer Mikro- und Nanotechnologien MacroNano registered, Technische Universitaet Ilmenau (Germany); Haehnlein, Bernd; Auge, Manuel; Pezoldt, Joerg [FG Nanotechnologie, Institut fuer Mikro- und Nanoelektronik und Institut fuer Mikro- und Nanotechnologien MacroNano registered, Technische Universitaet Ilmenau (Germany); Lebedev, Alexander A. [National Research University of Information Technologies, Mechanics and Optics, St. Petersburg (Russian Federation); Division Solid State Electronics, Ioffe Institute, Sankt-Peterburg (Russian Federation); Davydov, Valery Y. [Division Solid State Electronics, Ioffe Institute, Sankt-Peterburg (Russian Federation)

    2017-11-15

    Graphene nanoribbons show unique properties and have attracted a lot of attention in the recent past. Intensive theoretical and experimental studies on such nanostructures at both the fundamental and application-oriented levels have been performed. The present paper discusses the suitability of graphene nanoribbons devices for nanoelectronics and focuses on three specific device types - graphene nanoribbon MOSFETs, side-gate transistors, and three terminal junctions. It is shown that, on the one hand, experimental devices of each type of the three nanoribbon-based structures have been reported, that promising performance of these devices has been demonstrated and/or predicted, and that in part they possess functionalities not attainable with conventional semiconductor devices. On the other hand, it is emphasized that - in spite of the remarkable progress achieved during the past 10 years - graphene nanoribbon devices still face a lot of problems and that their prospects for future applications remain unclear. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. Sample processing device and method

    DEFF Research Database (Denmark)

    2011-01-01

    A sample processing device is disclosed, which sample processing device comprises a first substrate and a second substrate, where the first substrate has a first surface comprising two area types, a first area type with a first contact angle with water and a second area type with a second contact...... angle with water, the first contact angle being smaller than the second contact angle. The first substrate defines an inlet system and a preparation system in areas of the first type which two areas are separated by a barrier system in an area of the second type. The inlet system is adapted to receive...

  1. Electronic module for control of sample feeding device of spectrometers of X-ray fluorescent analysis of CRV type

    International Nuclear Information System (INIS)

    Petrov, V.A.; Fursov, A.V.

    2002-01-01

    The scheme of electronic module for sample feeding device control for the CRV type X-ray fluorescence analysis spectrometers is considered. This module provides realization of next functions: sample change operations and installation in starting position; signaling and defense at emergency cases; indication of any sample amount in the spectrometer chamber; testing function at tuning and testing of modules. All these principal functions are entrusted with microcontroller. Programming of the microcontroller is putting into effect by algorithm of the whole sample feeding device. In the capacity of microcontroller the single crystalline processor PICI16C54 and stepping motor of NV-306-V2202 model have been used

  2. Organic 'Plastic' Optoelectronic Devices

    International Nuclear Information System (INIS)

    Sariciftci, N.S.

    2006-01-01

    Recent developments on conjugated polymer based photovoltaic diodes and photoactive organic field effect transistors (photOFETs) are discussed. The photophysics of such devices is based on the photoinduced charge transfer from donor type semiconducting conjugated polymers onto acceptor type conjugated polymers or acceptor molecules such as Buckminsterfullerene, C 6 0. Potentially interesting applications include sensitization of the photoconductivity and photovoltaic phenomena as well as photoresponsive organic field effect transistors (photOFETs). Furthermore, organic polymeric/inorganic nanoparticle based 'hybrid' solar cells will be discussed. This talk gives an overview of materials' aspect, charge-transport, and device physics of organic diodes and field-effect transistors. Furthermore, due to the compatibility of carbon/hydrogen based organic semiconductors with organic biomolecules and living cells there can be a great opportunity to integrate such organic semiconductor devices (biOFETs) with the living organisms. In general the largely independent bio/lifesciences and information technology of today, can be thus bridged in an advanced cybernetic approach using organic semiconductor devices embedded in bio-lifesciences. This field of bio-organic electronic devices is proposed to be an important mission of organic semiconductor devices

  3. Mixed-Dimensionality VLSI-Type Configurable Tools for Virtual Prototyping of Biomicrofluidic Devices and Integrated Systems

    Science.gov (United States)

    Makhijani, Vinod B.; Przekwas, Andrzej J.

    2002-10-01

    This report presents results of a DARPA/MTO Composite CAD Project aimed to develop a comprehensive microsystem CAD environment, CFD-ACE+ Multiphysics, for bio and microfluidic devices and complete microsystems. The project began in July 1998, and was a three-year team effort between CFD Research Corporation, California Institute of Technology (CalTech), University of California, Berkeley (UCB), and Tanner Research, with Mr. Don Verlee from Abbott Labs participating as a consultant on the project. The overall objective of this project was to develop, validate and demonstrate several applications of a user-configurable VLSI-type mixed-dimensionality software tool for design of biomicrofluidics devices and integrated systems. The developed tool would provide high fidelity 3-D multiphysics modeling capability, l-D fluidic circuits modeling, and SPICE interface for system level simulations, and mixed-dimensionality design. It would combine tools for layouts and process fabrication, geometric modeling, and automated grid generation, and interfaces to EDA tools (e.g. Cadence) and MCAD tools (e.g. ProE).

  4. Radiation emitting devices regulations

    International Nuclear Information System (INIS)

    1970-01-01

    The Radiation Emitting Devices Regulations are the regulations referred to in the Radiation Emitting Devices Act and relate to the operation of devices. They include standards of design and construction, standards of functioning, warning symbol specifications in addition to information relating to the seizure and detention of machines failing to comply with the regulations. The radiation emitting devices consist of the following: television receivers, extra-oral dental x-ray equipment, microwave ovens, baggage inspection x-ray devices, demonstration--type gas discharge devices, photofluorographic x-ray equipment, laser scanners, demonstration lasers, low energy electron microscopes, high intensity mercury vapour discharge lamps, sunlamps, diagnostic x-ray equipment, ultrasound therapy devices, x-ray diffraction equipment, cabinet x-ray equipment and therapeutic x-ray equipment

  5. Powering biomedical devices

    CERN Document Server

    Romero, Edwar

    2013-01-01

    From exoskeletons to neural implants, biomedical devices are no less than life-changing. Compact and constant power sources are necessary to keep these devices running efficiently. Edwar Romero's Powering Biomedical Devices reviews the background, current technologies, and possible future developments of these power sources, examining not only the types of biomedical power sources available (macro, mini, MEMS, and nano), but also what they power (such as prostheses, insulin pumps, and muscular and neural stimulators), and how they work (covering batteries, biofluids, kinetic and ther

  6. 76 FR 21237 - Medical Devices; Obstetrical and Gynecological Devices; Classification of the Hemorrhoid...

    Science.gov (United States)

    2011-04-15

    ... type of device must submit to FDA a premarket notification, prior to marketing the device, which... directs agencies to assess all costs and benefits of available regulatory alternatives and, when... economic, environmental, public health and safety, and other advantages; distributive impacts; and equity...

  7. Artificial Pancreas Device Systems for the Closed-Loop Control of Type 1 Diabetes

    Science.gov (United States)

    Trevitt, Sara; Simpson, Sue; Wood, Annette

    2015-01-01

    Background: Closed-loop artificial pancreas device (APD) systems are externally worn medical devices that are being developed to enable people with type 1 diabetes to regulate their blood glucose levels in a more automated way. The innovative concept of this emerging technology is that hands-free, continuous, glycemic control can be achieved by using digital communication technology and advanced computer algorithms. Methods: A horizon scanning review of this field was conducted using online sources of intelligence to identify systems in development. The systems were classified into subtypes according to their level of automation, the hormonal and glycemic control approaches used, and their research setting. Results: Eighteen closed-loop APD systems were identified. All were being tested in clinical trials prior to potential commercialization. Six were being studied in the home setting, 5 in outpatient settings, and 7 in inpatient settings. It is estimated that 2 systems may become commercially available in the EU by the end of 2016, 1 during 2017, and 2 more in 2018. Conclusions: There are around 18 closed-loop APD systems progressing through early stages of clinical development. Only a few of these are currently in phase 3 trials and in settings that replicate real life. PMID:26589628

  8. Insertion devices at the advanced photon source

    International Nuclear Information System (INIS)

    Moog, E.R.

    1996-01-01

    The insertion devices being installed at the Advanced Photon Source cause the stored particle beam to wiggle, emitting x-rays with each wiggle. These x-rays combine to make an intense beam of radiation. Both wiggler and undulator types of insertion devices are being installed; the characteristics of the radiation produced by these two types of insertion devices are discussed, along with the reasons for those characteristics

  9. Fluid circulation control device

    International Nuclear Information System (INIS)

    Benard, Henri; Henocque, Jean.

    1982-01-01

    Horizontal fluid circulation control device, of the type having a pivoting flap. This device is intended for being fitted in the pipes of hydraulic installation, particularly in a bleed and venting system of a nuclear power station shifting radioactive or contaminated liquids. The characteristic of this device is the cut-out at the top of the flap to allow the air contained in the pipes to flow freely [fr

  10. A Novel Nonviral Gene Delivery System: Multifunctional Envelope-Type Nano Device

    Science.gov (United States)

    Hatakeyama, Hiroto; Akita, Hidetaka; Kogure, Kentaro; Harashima, Hideyoshi

    In this review we introduce a new concept for developing a nonviral gene delivery system which we call "Programmed Packaging." Based on this concept, we succeeded in developing a multifunctional envelope-type nano device (MEND), which exerts high transfection activities equivalent to those of an adenovirus in a dividing cell. The use of MEND has been extended to in vivo applications. PEG/peptide/DOPE ternary conjugate (PPD)-MEND, a new in vivo gene delivery system for the targeting of tumor cells that dissociates surface-modified PEG in tumor tissue by matrix metalloproteinase (MMP) and exerts significant transfection activities, was developed. In parallel with the development of MEND, a quantitative gene delivery system, Confocal Image-assisted 3-dimensionally integrated quantification (CIDIQ), also was developed. This method identified the rate-limiting step of the nonviral gene delivery system by comparing it with adenoviral-mediated gene delivery. The results of this analysis provide a new direction for the development of rational nonviral gene delivery systems.

  11. A feasibility study of a 3-day basal-bolus insulin delivery device in individuals with type 2 diabetes.

    Science.gov (United States)

    Mader, Julia K; Lilly, Leslie C; Aberer, Felix; Korsatko, Stefan; Strock, Ellie; Mazze, Roger S; Damsbo, Peter; Pieber, Thomas R

    2014-05-01

    This study tested the feasibility of transition from multiple daily injections (MDI) to a 3-day, basal-bolus insulin delivery device (PaQ) for type 2 diabetes (T2D). Twenty MDI-treated individuals with T2D with HbA(1c) ≤9% (75 mmol/mol) were enrolled in a single-center, single-arm pilot study, lasting three 2-week periods: baseline (MDI), transition to PaQ, and PaQ therapy. Feasibility of use, glycemic control, safety, and patient satisfaction were assessed. Nineteen participants transitioned to PaQ treatment and demonstrated competency in assembling, placing, and using the device. Self-monitored blood glucose and blinded continuous glucose-monitoring data showed glycemic control similar to MDI. Study participants reported high satisfaction and device acceptance. PaQ treatment is both feasible and acceptable in individuals with T2D. Transition from MDI is easy and safe. PaQ treatment might lead to better therapy adherence and improvements in glycemic control and clinical outcomes.

  12. Effects of the Reynolds number on two-dimensional dielectrophoretic motions of a pair of particles under a uniform electric field

    International Nuclear Information System (INIS)

    Kang, Sang Mo; Mannoor, Madhusoodanan; Maniyeri, Ranjith Maniyeri

    2016-01-01

    This paper presents two-dimensional direct numerical simulations to explore the effect of the Reynolds number on the Dielectrophoretic (DEP) motion of a pair of freely suspended particles in an unbounded viscous fluid under an external uniform electric field. Accordingly, the electric potential is obtained by solving the Maxwell'00s equation with a great sudden change in the electric conductivity at the particle-fluid interface and then the Maxwell stress tensor is integrated to determine the DEP force exerted on each particle. The fluid flow and particle movement, on the other hand, are predicted by solving the continuity and Navier-Stokes equations together with the kinetic equations. Numerical simulations are carried out using a finite volume approach, composed of a sharp interface method for the electric potential and a direct-forcing immersed-boundary method for the fluid flow. Through the simulations, it is found that both particles with the same sign of the conductivity revolve and eventually align themselves in a line with the electric field. With different signs, to the contrary, they revolve in the reverse way and eventually become lined up at a right angle with the electric field. The DEP motion also depends significantly on the Reynolds number defined based on the external electric field for all the combinations of the conductivity signs. When the Reynolds number is approximately below Re cr ≈ 0.1, the DEP motion becomes independent of the Reynolds number and thus can be exactly predicted by the no-inertia solver that neglects all the inertial and convective effects. With increasing Reynolds number above the critical number, on the other hand, the particles trace larger trajectories and thus take longer time during their revolution to the eventual in-line alignment.

  13. Effects of the Reynolds number on two-dimensional dielectrophoretic motions of a pair of particles under a uniform electric field

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sang Mo; Mannoor, Madhusoodanan [Dong-A University, Busan (Korea, Republic of); Maniyeri, Ranjith Maniyeri [National Institute of Technology Karnataka, Mangalore (India)

    2016-07-15

    This paper presents two-dimensional direct numerical simulations to explore the effect of the Reynolds number on the Dielectrophoretic (DEP) motion of a pair of freely suspended particles in an unbounded viscous fluid under an external uniform electric field. Accordingly, the electric potential is obtained by solving the Maxwell'00s equation with a great sudden change in the electric conductivity at the particle-fluid interface and then the Maxwell stress tensor is integrated to determine the DEP force exerted on each particle. The fluid flow and particle movement, on the other hand, are predicted by solving the continuity and Navier-Stokes equations together with the kinetic equations. Numerical simulations are carried out using a finite volume approach, composed of a sharp interface method for the electric potential and a direct-forcing immersed-boundary method for the fluid flow. Through the simulations, it is found that both particles with the same sign of the conductivity revolve and eventually align themselves in a line with the electric field. With different signs, to the contrary, they revolve in the reverse way and eventually become lined up at a right angle with the electric field. The DEP motion also depends significantly on the Reynolds number defined based on the external electric field for all the combinations of the conductivity signs. When the Reynolds number is approximately below Re{sub cr} ≈ 0.1, the DEP motion becomes independent of the Reynolds number and thus can be exactly predicted by the no-inertia solver that neglects all the inertial and convective effects. With increasing Reynolds number above the critical number, on the other hand, the particles trace larger trajectories and thus take longer time during their revolution to the eventual in-line alignment.

  14. Spill-Detector-and-Shutoff Device

    Science.gov (United States)

    Jarvis, M. R.; Fulton, D. S.

    1985-01-01

    Overflow in liquid chromatography systems rapidly detected and stopped. Spill-detector-and-shutoff device incorporated into liquid-chromatography system. When liquid from output nozzle spills on liquid sensor, device automatically shuts off pump and releases solenoid to pinch off flow in tube. Device uses common type of alarm circuit reset manually before normal operation resumes.

  15. Assistive acting movement therapy devices with pneumatic rotary-type soft actuators.

    Science.gov (United States)

    Wilkening, André; Baiden, David; Ivlev, Oleg

    2012-12-01

    Inherent compliance and assistive behavior are assumed to be essential properties for safe human-robot interaction. Rehabilitation robots demand the highest standards in this respect because the machine interacts directly with weak persons who are often sensitive to pain. Using novel soft fluidic actuators with rotary elastic chambers (REC actuators), compact, lightweight, and cost-effective therapeutic devices can be developed. This article describes modular design and control strategies for new assistive acting robotic devices for upper and lower extremities. Due to the inherent compliance and natural back-drivability of pneumatic REC actuators, these movement therapy devices provide gentle treatment, whereby the interaction forces between humans and the therapy device are estimated without the use of expensive force/torque sensors. An active model-based gravity compensation based on separated models of the robot and of the individual patient's extremity provides the basis for effective assistive control. The utilization of pneumatic actuators demands a special safety concept, which is merged with control algorithms to provide a sufficient level of safeness and to catch any possible system errors and/or emergency situations. A self-explanatory user interface allows for easy, intuitive handling. Prototypes are very comfortable for use due to several control routines that work in the background. Assistive devices have been tested extensively with several healthy persons; the knee/hip movement therapy device is now under clinical trials at the Clinic for Orthopaedics and Trauma Surgery at the Klinikum Stuttgart.

  16. Infrared-transmittance tunable metal-insulator conversion device with thin-film-transistor-type structure on a glass substrate

    Directory of Open Access Journals (Sweden)

    Takayoshi Katase

    2017-05-01

    Full Text Available Infrared (IR transmittance tunable metal-insulator conversion was demonstrated on a glass substrate by using thermochromic vanadium dioxide (VO2 as the active layer in a three-terminal thin-film-transistor-type device with water-infiltrated glass as the gate insulator. Alternative positive/negative gate-voltage applications induce the reversible protonation/deprotonation of a VO2 channel, and two-orders of magnitude modulation of sheet-resistance and 49% modulation of IR-transmittance were simultaneously demonstrated at room temperature by the metal-insulator phase conversion of VO2 in a non-volatile manner. The present device is operable by the room-temperature protonation in an all-solid-state structure, and thus it will provide a new gateway to future energy-saving technology as an advanced smart window.

  17. Thermonuclear device

    International Nuclear Information System (INIS)

    Yagi, Yasuomi; Takahashi, Ken; Hashimoto, Hiroshi.

    1984-01-01

    Purpose: To improve the plasma confining performances by bringing the irregular magnetic fields nearly to zero and decreasing the absolute value of the irregular magnetic fields at every positions. Constitution: The winding direction of a plurality of coil elements, for instance, double pan cake coils of toroidal coils in a torus type or mirror type thermonuclear device are reversed to each other in their laminating direction, whereby the irregular magnetic fields due to the coil-stepped portions in each toroidal coils are brought nearly to zero. This enables to bring the average irregular magnetic fields as a whole in the thermonuclear device nearly to zero, as well as, decrease the absolute value of the irregular magnetic fields in each positions. Thus, the plasma confining performances can be improved. (Moriyama, K.)

  18. Traversing incore probe device

    International Nuclear Information System (INIS)

    Yoshioka, Michiko.

    1985-01-01

    Purpose: To measure the neutron flux distribution in the reactor core always at a high accuracy. Constitution: A nuclear fission ionizing chamber type detector is disposed at the end of a cable for sending a detection signal of a traversing incore probe device and, further, a gamma-ray ionizing chamber type detector is connected in adjacent therewith and a selection circuit for selecting both of the detection signals and inputting them to a display device is disposed. Then, compensation for the neutron monitors is conducted by the gamma-ray ionizing chamber type detector during normal operation in which control rods are not driven and the positioning is carried out by the nuclear fission ionizing chamber type detector. Furthermore, both of the compensation for the neutron detector and the positioning are carried out by the nuclear fission ionizing chamber type detector upon starting where the control rods are driven. (Sekiya, K.)

  19. FDA publishes checklist of Y2K high-risk devices.

    Science.gov (United States)

    1999-09-01

    Key points. The federal Food and Drug Administration (FDA) has developed a list of types of medical devices that have the potential for the most serious consequences for patients should they fail because of Y2K-related problems. This list of computer-controlled potentially high-risk devices can provide a guide to health care facilities regarding the types of devices that should receive priority in their assessment and remediation of medical devices. The list may change as the FDA receives comments on the types of devices included in the list.

  20. Device-independent randomness amplification with a single device

    International Nuclear Information System (INIS)

    Plesch, Martin; Pivoluska, Matej

    2014-01-01

    Expansion and amplification of weak randomness with untrusted quantum devices has recently become a very fruitful topic of research. Here we contribute with a procedure for amplifying a single weak random source using tri-partite GHZ-type entangled states. If the quality of the source reaches a fixed threshold R=log 2 ⁡(10), perfect random bits can be produced. This technique can be used to extract randomness from sources that can't be extracted neither classically, nor by existing procedures developed for Santha–Vazirani sources. Our protocol works with a single fault-free device decomposable into three non-communicating parts, that is repeatedly reused throughout the amplification process. - Highlights: • We propose a protocol for device independent randomness amplification. • Our protocol repeatedly re-uses a single device decomposable into three parts. • Weak random sources with min-entropy rate greater than 1/4 log 2 ⁡(10) can be amplified. • Security against all-quantum adversaries is achieved

  1. Self-operation type power control device for nuclear reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kanbe, Mitsuru.

    1993-07-23

    The device of the present invention operates by sensing the temperature change of a reactor core in all of LMFBR type reactors irrespective of the scale of the reactor core power. That is, a region where liquid poison is filled is disposed at the upper portion and a region where sealed gases are filled is disposed at the lower portion of a pipe having both ends thereof being closed. When the pipe is inserted into the reactor core, the inner diameter of the pipe is determined smaller than a predetermined value so that the boundary between the liquid poison and the sealed gases in the pipe is maintained relative to an assumed maximum acceleration. The sealed gas region is disposed at the reactor core region. If the liquid poison is expanded by the elevation of the reactor core exit temperature, it is moved to the lower gas region, to control the reactor power. Since high reliability can be maintained over a long period of time by this method, it is suitable to FBR reactors disposed in such environments that maintenance can not easily be conducted, such as desserts, isolated islands and undeveloped countries. Further, it is also suitable to ultra small sized nuclear reactors disposed at environments that the direction and the magnitude of gravity are different from those on the ground. (I.S.).

  2. Self-operation type power control device for nuclear reactor

    International Nuclear Information System (INIS)

    Kanbe, Mitsuru.

    1993-01-01

    The device of the present invention operates by sensing the temperature change of a reactor core in all of LMFBR type reactors irrespective of the scale of the reactor core power. That is, a region where liquid poison is filled is disposed at the upper portion and a region where sealed gases are filled is disposed at the lower portion of a pipe having both ends thereof being closed. When the pipe is inserted into the reactor core, the inner diameter of the pipe is determined smaller than a predetermined value so that the boundary between the liquid poison and the sealed gases in the pipe is maintained relative to an assumed maximum acceleration. The sealed gas region is disposed at the reactor core region. If the liquid poison is expanded by the elevation of the reactor core exit temperature, it is moved to the lower gas region, to control the reactor power. Since high reliability can be maintained over a long period of time by this method, it is suitable to FBR reactors disposed in such environments that maintenance can not easily be conducted, such as desserts, isolated islands and undeveloped countries. Further, it is also suitable to ultra small sized nuclear reactors disposed at environments that the direction and the magnitude of gravity are different from those on the ground. (I.S.)

  3. An evaluation of sharp safety blood evacuation devices.

    Science.gov (United States)

    Ford, Joanna; Phillips, Peter

    This article describes an evaluation of three sharp safety blood evacuation devices in seven Welsh NHS boards and the Welsh Blood Service. Products consisted of two phlebotomy needles possessing safety shields and one phlebotomy device with wings, tubing and a retractable needle. The device companies provided the devices and appropriate training. Participating healthcare workers used the safety device instead of the conventional device to sample blood during the evaluation period and each type of device was evaluated in random order. Participants filled in a questionnaire for each type of device and then a further questionnaire comparing the two shielded evacuation needles with each other Results showed that responses to all three products were fairly positive, although each device was not liked by everyone who used it. When the two shielded evacuation devices were compared with each other, most users preferred the device with the shield positioned directly above the needle to the device with the shield at the side. However, in laboratory tests, the preferred device produced more fluid splatter than the other shielded device on activation.

  4. Medical Devices; Immunology and Microbiology Devices; Classification of the Device To Detect and Identify Microbial Pathogen Nucleic Acids in Cerebrospinal Fluid. Final order.

    Science.gov (United States)

    2017-10-20

    The Food and Drug Administration (FDA or we) is classifying the device to detect and identify microbial pathogen nucleic acids in cerebrospinal fluid into class II (special controls). The special controls that will apply to the device type are identified in this order and will be part of the codified language for the device to detect and identify microbial pathogen nucleic acids in cerebrospinal fluid’s classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  5. Dielectrophoresis Aligned Single-Walled Carbon Nanotubes as pH Sensors.

    Science.gov (United States)

    Li, Pengfei; Martin, Caleb M; Yeung, Kan Kan; Xue, Wei

    2011-01-31

    Here we report the fabrication and characterization of pH sensors using aligned single-walled carbon nanotubes (SWNTs). The SWNTs are dispersed in deionized (DI) water after chemical functionalization and filtration. They are deposited and organized on silicon substrates with the dielectrophoresis process. Electrodes with "teeth"-like patterns-fabricated with photolithography and wet etching-are used to generate concentrated electric fields and strong dielectrophoretic forces for the SWNTs to deposit and align in desired locations. The device fabrication is inexpensive, solution-based, and conducted at room temperature. The devices are used as pH sensors with the electrodes as the testing pads and the dielectrophoretically captured SWNTs as the sensing elements. When exposed to aqueous solutions with various pH values, the SWNTs change their resistance accordingly. The SWNT-based sensors demonstrate a linear relationship between the sensor resistance and the pH values in the range of 5-9. The characterization of multiple sensors proves that their pH sensitivity is highly repeatable. The real-time data acquisition shows that the sensor response time depends on the pH value, ranging from 2.26 s for the pH-5 solution to 23.82 s for the pH-9 solution. The long-term stability tests illustrate that the sensors can maintain their original sensitivity for a long period of time. The simple fabrication process, high sensitivity, and fast response of the SWNT-based sensors facilitate their applications in a wide range of areas.

  6. Cyclopentadithiophene–naphthalenediimide polymers; synthesis, characterisation, and n-type semiconducting properties in field-effect transistors and photovoltaic devices

    Energy Technology Data Exchange (ETDEWEB)

    Li, Chun-Han [Department of Chemical Engineering, Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing-Hua University, 101, Sec. 2, Kuang-Fu Road, Hsin-Chu 30013, Taiwan (China); Kettle, Jeff [School of Electronics, Bangor University, Dean st., Bangor, Gwynedd, LL57 1UT Wales (United Kingdom); Horie, Masaki, E-mail: mhorie@mx.nthu.edu.tw [Department of Chemical Engineering, Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing-Hua University, 101, Sec. 2, Kuang-Fu Road, Hsin-Chu 30013, Taiwan (China)

    2014-04-01

    The synthesis, characterisation, and device performance of a series of cyclopentadithiophene (CPDT)-naphthalenediimide (NDI) donor-acceptor-donor (D-A-D) polymers is reported. The monomers with various alkyl chains are synthesised via direct arylation using palladium complex catalyst. The monomers are then polymerised by oxidative polymerisation using FeCl{sub 3} to provide high molecular weight polymers (M{sub n} = 21,800–76,000). The polymer films show deep-red absorption including near-infrared region up to 1100 nm to give optical bandgap of approximately 1.16 eV. The polymers exhibit only n-type semiconducting properties giving the highest electron mobility of 9 × 10{sup -3} cm{sup 2} V{sup −1} s{sup −1} in organic field-effect transistors (OFETs). Organic photovoltaic (OPV) devices are fabricated from solutions of the polymers as acceptors and poly(3-hexylthiophene) (P3HT) as a donor. - Highlights: • Cyclopentadithiophene–naphthalenediimide oligomers were prepared by direct arylation. • The oligomers were polymerised by oxidative reaction using iron(III)chloride. • The polymer films show deep-red absorption up to 1100 nm with a bandgap of 1.1 eV. • The polymers exhibit only n-type semiconducting properties in OFETs and OPVs.

  7. Method of start-up of rotary plug sealing devices in FBR type reactors

    International Nuclear Information System (INIS)

    Sakuragi, Masanori; Akita, Haruo

    1980-01-01

    Purpose: To rapidly and safely start-up the rotary plug sealing device by controlling to eliminate the pressure difference in the pressures of gases exerting on the liquid surfaces in the inner and the outer cylinders of a sealing alloy vessel in the rotary plug of a FBR type reactor. Method: In a case where an abnormal state results in the pressure difference of gases exerted on the liquid surfaces in the inner and the outer cylinders of a vessel charged with sealing alloy in a rotary plug and the sealing valve for the back-up gas supply tube is rapidly closed to seal the sealing portion, the pressure in the gas supply tube is controlled so that the pressure difference in the gases exerted on the liquid surfaces in the inner and outer cylinders while closing the sealing valve. Then, after conforming that the pressure is controlled to a predetermined level at which the pressure difference can be regarded to be zero, the sealing valve is gradually opened while regulating the pressure in the gas supply tube so as to maintain the pressure difference to a predetermined level. This prevents the occurrence of external disturbances upon opening of the sealing valve and enables rapid and safety start-up for the rotary plug sealing device. (Moriyama, K.)

  8. Techniques to control and position laser targets. Final report

    International Nuclear Information System (INIS)

    Jones, T.B.

    1978-06-01

    The purpose of the work was to investigate the potential role of various electrohydrodynamic phenomena in the fabrication of small spherical particles and shells for laser target applications. A number of topics were considered. These included charged droplet levitation, specifically the combined effects of the Rayleigh limit and droplet elongation in the presence of electric fields. Two new levitation schemes for uncharged dielectric particles were studied. A dynamic dielectrophoretic levitation scheme was proposed and unsuccessful attempts were made to observe levitation with it. Another static dielectrophoretic levitation scheme was studied and used extensively. A theory was developed for this type of levitation, and a dielectric constant measurement scheme proposed. A charged droplet generator for the production of single droplets ( 4 /O 2 bubbles in Viscasil silicone fluid were conducted to learn about the possibility of using silane to form SiO 2 microballons from bubbles

  9. A semiconductor laser device

    Energy Technology Data Exchange (ETDEWEB)

    Takaro, K.; Naoki, T.; Satosi, K.; Yasutosi, K.

    1984-03-17

    A device is proposed which makes it possible to obtain single vertical mode emission in the absence of noise. Noise suppression is achieved by a method which determines the relationship between the donor densities in the second and third layers of an n type semiconductor laser, and the total output optical emission of layers with respect to the emission from the entire laser. The device consists of a photoresist film with a window applied to a 100 GaAs n type conductivity substrate using a standard method. Chemical etching through this window in the substrate is used to generate a slot approximately 1 micrometer in size. After the photoresist film is removed, the following layers are deposited from the liquid phase onto the substrate in the sequence indicated: a telurium doped protective layer of n type AlxGa(1-x) As; 2) an undoped active p type AlyGa(1-6) As layer and a tellurium doped upper protective n type conductivity GaAs layer.

  10. Sticker-type ECG/PPG concurrent monitoring system hybrid integration of CMOS SoC and organic sensor device.

    Science.gov (United States)

    Yongsu Lee; Hyeonwoo Lee; Seunghyup Yoo; Hoi-Jun Yoo

    2016-08-01

    The sticker-type sensor system is proposed targeting ECG/PPG concurrent monitoring for cardiovascular diseases. The stickers are composed of two types: Hub and Sensor-node (SN) sticker. Low-power CMOS SoC for measuring ECG and PPG signal is hybrid integrated with organic light emitting diodes (OLEDs) and organic photo detector (OPD). The sticker has only 2g weight and only consumes 141μW. The optical calibration loop is adopted for maintaining SNR of PPG signal higher than 30dB. The pulse arrival time (PAT) and SpO2 value can be extracted from various body parts and verified comparing with the reference device from 20 people in-vivo experiments.

  11. P-type SnO thin films and SnO/ZnO heterostructures for all-oxide electronic and optoelectronic device applications

    Energy Technology Data Exchange (ETDEWEB)

    Saji, Kachirayil J. [Nanostructured Materials Research Laboratory, Department of Materials Science & Engineering, University of Utah, Salt Lake City, UT 84112 (United States); Department of Physics, Govt. Victoria College, University of Calicut, Palakkad 678 001 (India); Venkata Subbaiah, Y.P. [Nanostructured Materials Research Laboratory, Department of Materials Science & Engineering, University of Utah, Salt Lake City, UT 84112 (United States); Department of Physics, Yogi Vemana University, Kadapa, Andhra Pradesh 516003 (India); Tian, Kun [Nanostructured Materials Research Laboratory, Department of Materials Science & Engineering, University of Utah, Salt Lake City, UT 84112 (United States); Tiwari, Ashutosh, E-mail: tiwari@eng.utah.edu [Nanostructured Materials Research Laboratory, Department of Materials Science & Engineering, University of Utah, Salt Lake City, UT 84112 (United States)

    2016-04-30

    Tin monoxide (SnO) is considered as one of the most important p-type oxides available to date. Thin films of SnO have been reported to possess both an indirect bandgap (~ 0.7 eV) and a direct bandgap (~ 2.8 eV) with quite high hole mobility (~ 7 cm{sup 2}/Vs) values. Moreover, the hole density in these films can be tuned from 10{sup 15}–10{sup 19} cm{sup −3} just by controlling the thin film deposition parameters. Because of the above attributes, SnO thin films offer great potential for fabricating modern electronic and optoelectronic devices. In this article, we are reviewing the most recent developments in this field and also presenting some of our own results on SnO thin films grown by pulsed laser deposition technique. We have also proposed a p–n heterostructure comprising of p-type SnO and n-type ZnO which can pave way for realizing next-generation, all-oxide transparent electronic devices. - Highlights: • We reviewed recent developments on p-type SnO thin film research. • Discussed the optical and electrical properties of SnO thin films • Bipolar conduction in SnO is discussed. • Optoelectronic properties of SnO–ZnO composite system are discussed. • Proposed SnO–ZnO heterojunction band structure.

  12. Memristive device based on a depletion-type SONOS field effect transistor

    Science.gov (United States)

    Himmel, N.; Ziegler, M.; Mähne, H.; Thiem, S.; Winterfeld, H.; Kohlstedt, H.

    2017-06-01

    State-of-the-art SONOS (silicon-oxide-nitride-oxide-polysilicon) field effect transistors were operated in a memristive switching mode. The circuit design is a variation of the MemFlash concept and the particular properties of depletion type SONOS-transistors were taken into account. The transistor was externally wired with a resistively shunted pn-diode. Experimental current-voltage curves show analog bipolar switching characteristics within a bias voltage range of ±10 V, exhibiting a pronounced asymmetric hysteresis loop. The experimental data are confirmed by SPICE simulations. The underlying memristive mechanism is purely electronic, which eliminates an initial forming step of the as-fabricated cells. This fact, together with reasonable design flexibility, in particular to adjust the maximum R ON/R OFF ratio, makes these cells attractive for neuromorphic applications. The relative large set and reset voltage around ±10 V might be decreased by using thinner gate-oxides. The all-electric operation principle, in combination with an established silicon manufacturing process of SONOS devices at the Semiconductor Foundry X-FAB, promise reliable operation, low parameter spread and high integration density.

  13. Prevention device for rapid reactor core shutdown in BWR type reactors

    International Nuclear Information System (INIS)

    Koshi, Yuji; Karatsu, Hiroyuki.

    1986-01-01

    Purpose: To surely prevent rapid shutdown of a nuclear reactor upon partial load interruption due to rapid increase in the system frequency. Constitution: If a partial load interruption greater than the sum of the turbine by-pass valve capacity and the load setting bias portion is applied in a BWR type power plant, the amount of main steams issued from the reactor is decreased, the thermal input/output balance of the reactor is lost, the reactor pressure is increased, the void is collapsed, the neutron fluxes are increased and the reactor power rises to generate rapid reactor shutdown. In view of the above, the turbine speed signal is compared with a speed setting value in a recycling flowrate control device and the recycling pump is controlled to decrease the recycling flowrate in order to compensate the increase in the neutron fluxes accompanying the reactor power up. In this way, transient changes in the reactor core pressure and the neutron fluxes are kept within a setting point for the rapid reactor shutdown operation thereby enabling to continue the plant operation. (Horiuchi, T.)

  14. Assistive Devices

    Science.gov (United States)

    If you have a disability or injury, you may use a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get ...

  15. Multi-shot type pellet injection device

    International Nuclear Information System (INIS)

    Onozuka, Masaki; Uchikawa, Takashi; Kuribayashi, Shitomi.

    1988-01-01

    Purpose: To inject pellets at high speed without melting or sublimating not-injected pellets even at a long pellet injection interval. Constitution: In the conventional multi-shot pellet injection device, the pellet injection interval is set depending on the plasma retention time. However, as the pellet injection interval is increased, not-injected pellets are melted or sublimated due to the introduced heat of acceleration gases supplied from an acceleration gas introduction pipe to give an effect on the dimensional shape of the pellets. In view of the above, a plurality of pellet forming and injection portions each comprising a carrier, an injection pipe and a holder are disposed independently of each other and pellets are formed and injected independently to thereby prevent the thermal effects of the acceleration gases. (Kamimura, M.)

  16. Multi-shot type pellet injection device

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, Masaki; Uchikawa, Takashi; Kuribayashi, Shitomi.

    1988-07-27

    Purpose: To inject pellets at high speed without melting or sublimating not-injected pellets even at a long pellet injection interval. Constitution: In the conventional multi-shot pellet injection device, the pellet injection interval is set depending on the plasma retention time. However, as the pellet injection interval is increased, not-injected pellets are melted or sublimated due to the introduced heat of acceleration gases supplied from an acceleration gas introduction pipe to give an effect on the dimensional shape of the pellets. In view of the above, a plurality of pellet forming and injection portions each comprising a carrier, an injection pipe and a holder are disposed independently of each other and pellets are formed and injected independently to thereby prevent the thermal effects of the acceleration gases. (Kamimura, M.).

  17. 76 FR 43119 - Medical Devices; General and Plastic Surgery Devices; Classification of the Focused Ultrasound...

    Science.gov (United States)

    2011-07-20

    ... type of device must submit to FDA a premarket notification, prior to marketing the device, which... Orders 12866 and 13563 direct Agencies to assess all costs and benefits of available regulatory... (including potential economic, environmental, public health and safety, and other advantages; distributive...

  18. Incore inspection and repairing device

    International Nuclear Information System (INIS)

    Ito, Arata; Kimura, Motohiko

    1998-01-01

    The present invention provides a device for inspecting and repairing the inside of a reactor container even if it is narrow, with no trouble by using a swimming-type operation robot. Namely, the device of the present invention conducts inspection and repairing operations for the inside of the reactor by introducing a swimming type operation robot into the reactor container. The swimming-type operation robot comprises a robot main body having a propeller, a balancer operably disposed to the robot main body and an inspection and repairing unit attached detachable to the balancer. In the device of the present invention, since the inspection and preparing unit is attached detachably to the swimming robot, a robot which transports tools is formed as a standard product. As a result, the production cost can be reduced, and the reliability of products can be improved. Appropriate operations can be conducted by using best tools. (I.S.)

  19. The influence on the contact condition and initial fixation stability of the main design parameters of a self-expansion type anterior cruciate ligament fixation device

    International Nuclear Information System (INIS)

    Kim, Jong Dae; Oh, Chae Youn; Kim, Cheol Sang

    2008-01-01

    This paper proposes a self-expansion type anterior cruciate ligament fixation device. The proposed fixation device provides graft fixation force by maintaining contact with the bone tunnel. Since the device maintains contact with the bone tunnel by the force that expands by the self-driven elastic force of the device, the main design parameters that determine the performance of this device are the ring thickness and expansion angle. This paper develops the three-dimensional finite element models of the fixation device and bone. By simulation with the developed finite element model, this paper studies the influence of the main design parameters of the device on the maximum stress around the ring when grasping the fixation device. Through the analysis of the stress on the bone tunnel wall when the fixation device comes in contact with the bone tunnel, this paper shows the influence of the main design parameters of the fixation device on the contact condition. In addition, through the analysis of the migration that occur upon application of the pull-out force, this paper studies the influence of the main design parameters on the initial fixation stability of the fixation device

  20. The influence on the contact condition and initial fixation stability of the main design parameters of a self-expansion type anterior cruciate ligament fixation device

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Dae [Jeonju University, Jeonju (Korea, Republic of); Oh, Chae Youn; Kim, Cheol Sang [Chonbuk National University, Jeonju (Korea, Republic of)

    2008-12-15

    This paper proposes a self-expansion type anterior cruciate ligament fixation device. The proposed fixation device provides graft fixation force by maintaining contact with the bone tunnel. Since the device maintains contact with the bone tunnel by the force that expands by the self-driven elastic force of the device, the main design parameters that determine the performance of this device are the ring thickness and expansion angle. This paper develops the three-dimensional finite element models of the fixation device and bone. By simulation with the developed finite element model, this paper studies the influence of the main design parameters of the device on the maximum stress around the ring when grasping the fixation device. Through the analysis of the stress on the bone tunnel wall when the fixation device comes in contact with the bone tunnel, this paper shows the influence of the main design parameters of the fixation device on the contact condition. In addition, through the analysis of the migration that occur upon application of the pull-out force, this paper studies the influence of the main design parameters on the initial fixation stability of the fixation device

  1. Plasma shutdown device

    International Nuclear Information System (INIS)

    Hosogane, Nobuyuki; Nakayama, Takahide.

    1985-01-01

    Purpose: To prevent concentration of plasma currents to the plasma center upon plasma shutdown in a torus type thermonuclear device by the injection of fuels to the plasma center thereby prevent plasma disruption at the plasma center. Constitution: The plasma shutdown device comprises a plasma current measuring device that measures the current distribution of plasmas confined within a vacuum vessel and outputs a control signal for cooling the plasma center when the plasma currents concentrate to the plasma center and a fuel supply device that supplies fuels to the plasma center for cooling the center. The fuels are injected in the form of pellets into the plasmas. The direction and the velocity of the injection are set such that the pellets are ionized at the center of the plasmas. (Horiuchi, T.)

  2. Temperature rise during removal of fractured components out of the implant body: an in vitro study comparing two ultrasonic devices and five implant types.

    Science.gov (United States)

    Meisberger, Eric W; Bakker, Sjoerd J G; Cune, Marco S

    2015-12-01

    Ultrasonic instrumentation under magnification may facilitate mobilization of screw remnants but may induce heat trauma to surrounding bone. An increase of 5°C is considered detrimental to osseointegration. The objective of this investigation was to examine the rise in temperature of the outer implant body after 30 s of ultrasonic instrumentation to the inner part, in relation to implant type, type of ultrasonic equipment, and the use of coolants in vitro. Two ultrasonic devices (Satelec Suprasson T Max and Electro Medical Systems (EMS) miniMaster) were used on five different implant types that were provided with a thermo couple (Astra 3.5 mm, bone level Regular CrossFit (RC) 4.1 mm, bone level Narrow CrossFit (NC) 3.3 mm, Straumann tissue level regular body regular neck 3.3 mm, and Straumann tissue level wide body regular neck 4.8 mm), either with or without cooling during 30 s. Temperature rise at this point in time is the primary outcome measure. In addition, the mean maximum rise in temperature (all implants combined) was assessed and statistically compared among devices, implant systems, and cooling mode (independent t-tests, ANOVA, and post hoc analysis). The Satelec device without cooling induces the highest temperature change of up to 13°C, particularly in both bone level implants (p < 0.05) but appears safe for approximately 10 s of continuous instrumentation, after which a cooling down period is rational. Cooling is effective for both devices. However, when the Satelec device is used with coolant for a longer period of time, a rise in temperature must be anticipated after cessation of instrumentation, and post-operational cooling is advised. The in vitro setup used in this experiment implies that care should be taken when translating the observations to clinical recommendations, but it is carefully suggested that the EMS device causes limited rise in temperature, even without coolant.

  3. Medical Devices; Obstetrical and Gynecological Devices; Classification of the Fetal Head Elevator. Final order.

    Science.gov (United States)

    2017-12-19

    The Food and Drug Administration (FDA or we) is classifying the fetal head elevator into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the fetal head elevator's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  4. Quantum theory of novel parametric devices

    International Nuclear Information System (INIS)

    Drummond, P.D.; Reid, M.D.; Dechoum, K.; Chaturvedi, S.; Olsen, M.; Kheruntsyan, K.; Bradley, A.

    2005-01-01

    While the parametric amplifier is a widely used and important source of entangled and squeezed photons, there are many possible ways to investigate the physics of intracavity parametric devices. Novel quantum theory of parametric devices in this talk will cover several new types of unconventional devices, including the following topics:- Critical intracavity paramp - We calculate intrinsic limits to entanglement of a quantum paramp, caused by nonlinear effects originating in phase noise of the pump. - Degenerate planar paramp - We obtain universal quantum critical fluctuations in a planar paramp device by mapping to the equations of magnetic Lifshitz points Nondegenerate planar paramp - The Mermin-Wagner theorem is used to demonstrate that there is no phase transition in the case of a nondegenerate planar device - Coupled channel paramp - A robust and novel integrated entanglement source can be generated using type I waveguides coupled inside a cavity to generate spatial entanglement - Cascade paramps - This possible 'GHZ-type' source is obtained by cascading successive down conversion crystals inside the same cavity, giving two thresholds Parallel paramps - Tripartite entanglement can be generated if three intracavity paramp crystals are operated in parallel, each idler mode acting as a signal for the next. Finally, we briefly treat the relevant experimental developments. (author)

  5. Neutronic, thermal-hydraulics and safety calculations of a Miniplate Irradiation Device (MID) of dispersion type fuel elements

    International Nuclear Information System (INIS)

    Domingos, Douglas Borges

    2010-01-01

    Neutronic, thermal-hydraulics and accident analysis calculations were developed to estimate the safety of a Miniplate Irradiation Device (MID) to be placed in the IEA-R1 reactor core. The irradiation device is used to receive miniplates of U 3 O 8 -Al and U 3 Si 2 - Al dispersion fuels, LEU type (19.75 % 235 U) with uranium densities of, respectively, 3.2 gU/cm 3 and 4.8 gU/cm 3 . The fuel miniplates will be irradiated to nominal 235 U burnup levels of 50% and 80%, in order to qualify the above high-density dispersion fuels to be used in the Brazilian Multipurpose Reactor (RMB), now in the conception phase. For the neutronic calculation, the computer codes CITATION and 2DB were utilized. The computer code FLOW was used to calculate the coolant flow rate in the irradiation device, allowing the determination of the fuel miniplate temperatures with the computer model MTRCR-IEA-R1. A postulated Loss of Coolant Accident (LOCA) was analyzed with the computer codes LOSS and TEMPLOCA, allowing the calculation of the fuel miniplate temperatures after the reactor pool draining. The calculations showed that the irradiation should occur without adverse consequences in the IEA-R1 reactor. (author)

  6. Development of mechanical circulatory support devices in China.

    Science.gov (United States)

    Wang, Wei; Zhu, De-Ming; Ding, Wen-Xiang

    2009-11-01

    Myocardial dysfunction leading to low cardiac output syndrome is a common clinical pathophysiological state. Currently, the use of mechanical circulatory support (MCS) is an essential aspect of the treatment of patients with cardiac failure. Several groups in China are engaged in the design and development of MCS devices. These devices can be classified as pulsatile, rotary, and total artificial heart (TAH). There are two types of pulsatile pump, which are driven by air (pneumatic). One of these pumps, the Luo-Ye pump, has been used clinically for short-term support since 1998. The other is a push-plate left ventricular device, which has a variable rate mode. Various rotary devices are classified into axial and centrifugal pumps, depending on the impeller geometry. Most rotary pumps are based on the maglev principle, and some types have been used clinically. Others are still being studied in the laboratory or in animal experiments. Furthermore, certain types of total implantable pump, such as the UJS-III axial pump and the UJS-IV aortic valvo-pump, have been developed. Only one type of TAH has been developed in China. The main constituents of this artificial heart are two axial pumps, two reservoir tanks mimicking the right and left atria, flow meters, two pressure gauges, and a resistance adaptor. Although the development of mechanical assist devices in China is still in a nascent stage, a number of different types of MCS devices are currently being studied.

  7. Personal Flotation Devices Research. Volume 2. Research Report.

    Science.gov (United States)

    1978-01-01

    approval if it was not designed to the Type I, I , I , or IV criteria. This approach allows high life-saving effectiveness devices to enter the market if...Type X devices enjoy a market reception on the order of the reception given to Type III (the costs for Type Xs and Type Ills would be similar), an...addition to attempts to document the rate of wear of PFDs , previous researc h has measured various design features of PFDs and boater ’s attitudes . The

  8. A method and device for reducing background in well logging devices using inelastic gamma rays

    International Nuclear Information System (INIS)

    Culver, R.B.

    1974-01-01

    The invention relates to a well logging device, of the type comprising a source of pulsed neutrons and means for detecting radioactivity. The device comprises means adapted to interrupt the neutron source emission in response to the detection of a single gamma radiation showing a pre-determined feature [fr

  9. Smart design to resolve spectral overlapping of phosphor-in-glass for high-powered remote-type white light-emitting devices.

    Science.gov (United States)

    Lee, Jin Seok; Arunkumar, P; Kim, Sunghoon; Lee, In Jae; Lee, Hyungeui; Im, Won Bin

    2014-02-15

    The white light-emitting diode (WLED) is a state-of-the-art solid state technology, which has replaced conventional lighting systems due to its reduced energy consumption, its reliability, and long life. However, the WLED presents acute challenges in device engineering, due to its lack of color purity, efficacy, and thermal stability of the lighting devices. The prime cause for inadequacies in color purity and luminous efficiency is the spectral overlapping of red components with yellow/green emissions when generating white light by pumping a blue InGaN chip with yellow YAG:Ce³⁺ phosphor, where red phosphor is included, to compensate for deficiencies in the red region. An innovative strategy was formulated to resolve this spectral overlapping by alternatively arranging phosphor-in-glass (PiG) through cutting and reassembling the commercial red CaAlSiN₃:Eu²⁺ and green Lu₃Al₅O₁₂:Ce³⁺ PiG. PiGs were fabricated using glass frits with a low softening temperature of 600°C, which exhibited excellent thermal stability and high transparency, improving life time even at an operating temperature of 200°C. This strategy overcomes the spectral overlapping issue more efficiently than the randomly mixed and patented stacking design of multiple phosphors for a remote-type WLED. The protocol for the current design of PiG possesses excellent thermal and chemical stability with high luminous efficiency and color purity is an attempt to make smarter solid state lighting for high-powered remote-type white light-emitting devices.

  10. Pragmatic setup for bioparticle responses by dielectrophoresis for resource limited environment application

    Science.gov (United States)

    Ali, Mohd Anuar Md; Yeop Majlis, Burhanuddin; Kayani, Aminuddin Ahmad

    2017-12-01

    Various dielectrophoretic responses of bioparticles, including cell-chain, spinning, rotation and clustering, are of high interest in the field due to their benefit into application for biomedical and clinical implementation potential. Numerous attempts using sophisticated equipment setup have been studied to perform those dielectrophoretic responses, however, for development into resource limited environment application, such as portable, sustainable and environmental friendly diagnostic tools, establishment of pragmatic setup using standard, non-sophisticated and low-cost equipment is of important task. Here we show the advantages in the judicious design optimization of tip microelectrode, also with selection of suspending medium and optimization of electric signal configuration in establishing setup that can promote the aforementioned dielectrophoretic responses within standard equipments, i.e. pragmatic setup.

  11. Vascular access strategy for delivering long-term antimicrobials to patients with infective endocarditis: device type, risk of infection and mortality.

    Science.gov (United States)

    Ahmed, F Z; Baig, W W; Munyombwe, T; West, R; Sandoe, J A T

    2013-01-01

    This paper reports the use of different vascular access devices and the incidence of intravascular catheter-related infection (CRI) in patients receiving intravenous antibiotics for infective endocarditis (IE). To examine whether rates of infection vary with type of vascular access device, and assess the impact of CRI on mortality in IE. A prospective observational service evaluation of all inpatients who received intravenous antibiotics for IE was performed. In total, 114 inpatients were evaluated. All cases of CRI [including exit-site infection, intravascular catheter-related bloodstream infection (CRBSI) and mortality] were recorded. Tunnelled and non-tunnelled central venous catheters (CVCs), and peripherally inserted cannulae were used for antibiotic delivery. There were 15 episodes of CRI, 11 of which were CRBSI (all associated with CVC use). The remainder comprised uncomplicated exit-site infections. Use of tunnelled CVCs [hazard ratio (HR) 16.95, 95% confidence interval (CI) 2.13-134.93; P = 0.007] and non-tunnelled CVCs (HR 24.54, 95% CI 2.83-212.55; P = 0.004) was associated with a significantly increased risk of CRI. Risk of mortality increased significantly with Staphylococcus aureus as the cause of IE (P < 0.001) and CRBSI (P = 0.034). Risk of CRI in patients with IE is linked to the type of vascular access device used. Rates of CRBSI were greatest with CVCs, while peripheral venous cannulae were not associated with CRBSI or serious sequelae. Many patients (40%) tolerated complete treatment courses delivered via peripheral cannulae. These findings confirm the importance of device selection in reducing the risk of CRI; a potentially modifiable variable that impacts on outcome and mortality in IE. Copyright © 2012 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  12. Graphene-edge dielectrophoretic tweezers for trapping of biomolecules.

    Science.gov (United States)

    Barik, Avijit; Zhang, Yao; Grassi, Roberto; Nadappuram, Binoy Paulose; Edel, Joshua B; Low, Tony; Koester, Steven J; Oh, Sang-Hyun

    2017-11-30

    The many unique properties of graphene, such as the tunable optical, electrical, and plasmonic response make it ideally suited for applications such as biosensing. As with other surface-based biosensors, however, the performance is limited by the diffusive transport of target molecules to the surface. Here we show that atomically sharp edges of monolayer graphene can generate singular electrical field gradients for trapping biomolecules via dielectrophoresis. Graphene-edge dielectrophoresis pushes the physical limit of gradient-force-based trapping by creating atomically sharp tweezers. We have fabricated locally backgated devices with an 8-nm-thick HfO 2 dielectric layer and chemical-vapor-deposited graphene to generate 10× higher gradient forces as compared to metal electrodes. We further demonstrate near-100% position-controlled particle trapping at voltages as low as 0.45 V with nanodiamonds, nanobeads, and DNA from bulk solution within seconds. This trapping scheme can be seamlessly integrated with sensors utilizing graphene as well as other two-dimensional materials.

  13. Compact and tunable size-based dielectrophoretic flow fractionation

    International Nuclear Information System (INIS)

    Chuang, Han-Sheng; Chung, Tien-Yu; Li, Yun

    2014-01-01

    A compact and tunable size-based flow fractionation microchip using negative dielectrophoresis (DEP) is presented in this paper. In the microchip, a sample containing a mixture of particles is hydrodynamically focused in a contraction section and then sorted by size after flowing over planar interdigitated electrodes. The electrodes and flow chamber were aligned at an angle of 45° to produce effective sorting. 1, 2.5 and 4.8 µm polystyrene (PS) particles were successfully separated into three distinct streams in a short distance (1 mm) and collected in different outlet channels. The sorting was subjected to flow rates and electric potential. The experimental sorting efficiencies of 1, 2.5 and 4.8 µm particles reached 97.2%, 79.6% and 99.8%, respectively. With the same device, lipid vesicle sorting was demonstrated. 86.9% of vesicles larger than 10 µm were effectively extracted from the sample stream. Likewise, sorting of other biological particles can be achieved in the same fashion. (paper)

  14. Effect of device-guided breathing exercises on blood pressure in hypertensive patients with type 2 diabetes mellitus : A randomized controlled trial

    NARCIS (Netherlands)

    Logtenberg, Susan J.; Kleefstra, Nanne; Houweling, Sebastlaan T.; Groenier, Klaas H.; Bilo, Henk J.

    Objective In patients with type 2 diabetes mellitus (DM2), it is hard to reach treatment objectives for blood pressure (BP) with classical treatment options. Recently, reducing breathing frequency has been advocated as a method to reduce BP. We examined if an electronic device such as Resperate, by

  15. Medical Devices; Neurological Devices; Classification of the External Vagal Nerve Stimulator for Headache. Final order.

    Science.gov (United States)

    2017-12-27

    The Food and Drug Administration (FDA or we) is classifying the external vagal nerve stimulator for headache into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the external vagal nerve stimulator for headache's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  16. Fuel inspection device

    International Nuclear Information System (INIS)

    Tsuji, Tadashi.

    1990-01-01

    The fuel inspection device of the present invention has a feature of obtaining an optimum illumination upon fuel rod interval inspection operation in a fuel pool. That is, an illumination main body used underwater is connected to a cable which is led out on a floor. A light control device is attached to the other end of the cable and an electric power cable is connected to the light control device. A light source (for example, incandescent lamp) is incorporated in the casing of the illumination main body, and a diffusion plate is disposed at the front to provide a plane light source. The light control device has a light control knob capable of remote-controlling the brightness of the light of the illumination main body. In the fuel inspection device thus constituted, halation is scarcely caused on the image screen upon inspection of fuels by a submerged type television camera to facilitate control upon inspection. Accordingly, efficiency of the fuel inspection can be improved to shorten the operation time. (I.S.)

  17. Dielectrophoresis Aligned Single-Walled Carbon Nanotubes as pH Sensors

    Directory of Open Access Journals (Sweden)

    Wei Xue

    2011-01-01

    Full Text Available Here we report the fabrication and characterization of pH sensors using aligned single-walled carbon nanotubes (SWNTs. The SWNTs are dispersed in deionized (DI water after chemical functionalization and filtration. They are deposited and organized on silicon substrates with the dielectrophoresis process. Electrodes with “teeth”-like patterns—fabricated with photolithography and wet etching—are used to generate concentrated electric fields and strong dielectrophoretic forces for the SWNTs to deposit and align in desired locations. The device fabrication is inexpensive, solution-based, and conducted at room temperature. The devices are used as pH sensors with the electrodes as the testing pads and the dielectrophoretically captured SWNTs as the sensing elements. When exposed to aqueous solutions with various pH values, the SWNTs change their resistance accordingly. The SWNT-based sensors demonstrate a linear relationship between the sensor resistance and the pH values in the range of 5–9. The characterization of multiple sensors proves that their pH sensitivity is highly repeatable. The real-time data acquisition shows that the sensor response time depends on the pH value, ranging from 2.26 s for the pH-5 solution to 23.82 s for the pH-9 solution. The long-term stability tests illustrate that the sensors can maintain their original sensitivity for a long period of time. The simple fabrication process, high sensitivity, and fast response of the SWNT-based sensors facilitate their applications in a wide range of areas.

  18. Thermoelectric materials and devices made therewith

    International Nuclear Information System (INIS)

    Moore, D.E.

    1985-01-01

    The disclosed invention includes improved devices and materials for thermoelectric conversion, particularly for operation at temperatures of 300 0 C. and below. Disordered p-type semiconductor elements incorporate compound adjuvants of silver and lead to achieve enhanced ''figure of merit'' values and corresponding increased efficiencies of thermoelectric conversion. Similar results are obtained with disordered n-type elements by employing lowered selenium contents, preferably in combination with cuprous bromide. Improved conversion devices include powder pressed elements from one or both of these materials

  19. Plastic photovoltaic devices

    OpenAIRE

    Niyazi Serdar Sariciftci

    2004-01-01

    The development of organic, polymer-based photovoltaic elements has introduced the possibility of obtaining cheap and easy-to-produce energy from light. Photoinduced electron transfer from donor-type semiconducting polymers onto acceptor-type polymers or molecules, such as C60, is the basic phenomenon utilized in these photovoltaic devices. This process mimics the early photo-effects in natural photosynthesis. The polymeric semiconductors combine the photoelectrical properties of inorganic se...

  20. Development of a portable quality control application using a tablet-type electronic device.

    Science.gov (United States)

    Ono, Tomohiro; Miyabe, Yuki; Akimoto, Mami; Mukumoto, Nobutaka; Ishihara, Yoshitomo; Nakamura, Mitsuhiro; Mizowaki, Takashi

    2018-03-01

    Our aim was to develop a portable quality control (QC) application using a thermometer, a barometer, an angle gauge, and a range finder implemented in a tablet-type consumer electronic device (CED) and to assess the accuracies of the measurements made. The QC application was programmed using Java and OpenCV libraries. First, temperature and atmospheric pressure were measured over 30 days using the temperature and pressure sensors of the CED and compared with those measured by a double-tube thermometer and a digital barometer. Second, the angle gauge was developed using the accelerometer of the CED. The roll and pitch angles of the CED were measured from 0 to 90° at intervals of 10° in the clockwise (CW) and counterclockwise (CCW) directions. The values were compared with those measured by a digital angle gauge. Third, a range finder was developed using the tablet's built-in camera and image-processing capacities. Surrogate markers were detected by the camera and their positions converted to actual positions using a homographic transformation method. Fiducial markers were placed on a treatment couch and moved 100 mm in 10-mm steps in both the lateral and longitudinal directions. The values were compared with those measured by the digital output of the treatment couch. The differences between CED values and those of other devices were compared by calculating means ± standard deviations (SDs). The means ± SDs of differences in temperature and atmospheric pressure were -0.07 ± 0.25°C and 0.05 ± 0.10 hPa, respectively. The means ± SDs of the difference in angle was -0.17 ± 0.87° (0.15 ± 0.23° degrees excluding the 90° angle). The means ± SDs of distances were 0.01 ± 0.07 mm in both the lateral and longitudinal directions. Our portable QC application was accurate and may be used instead of standard measuring devices. Our portable CED is efficient and simple when used in the field of medical physics. © 2018 American Association of

  1. Control rod drive hydraulic device

    International Nuclear Information System (INIS)

    Takekawa, Toru.

    1994-01-01

    The device of the present invention can reliably prevent a possible erroneous withdrawal of control rod driving mechanism when the pressure of a coolant line is increased by isolation operation of hydraulic control units upon periodical inspection for a BWR type reactor. That is, a coolant line is connected to the downstream of a hydraulic supply device. The coolant line is connected to a hydraulic control unit. A coolant hydraulic detection device and a pressure setting device are disposed to the coolant line. A closing signal line and a returning signal line are disposed, which connect the hydraulic supply device and a flow rate control valve for the hydraulic setting device. In the device of the present invention, even if pressure of supplied coolants is elevated due to isolation of hydraulic control units, the elevation of the hydraulic pressure can be prevented. Accordingly, reliability upon periodical reactor inspection can be improved. Further, the facility is simplified and the installation to an existent facility is easy. (I.S.)

  2. Quality index of radiological devices: results of one year of use.

    Science.gov (United States)

    Tofani, Alessandro; Imbordino, Patrizia; Lecci, Antonio; Bonannini, Claudia; Del Corona, Alberto; Pizzi, Stefano

    2003-01-01

    The physical quality index (QI) of radiological devices summarises in a single numerical value between 0 and 1 the results of constancy tests. The aim of this paper is to illustrate the results of the use of such an index on all public radiological devices in the Livorno province over one year. The quality index was calculated for 82 radiological devices of a wide range of types by implementing its algorithm in a spreadsheet-based software for the automatic handling of quality control data. The distribution of quality index values was computed together with the associated statistical quantities. This distribution is strongly asymmetrical, with a sharp peak near the highest QI values. The mean quality index values for the different types of device show some inhomogeneity: in particular, mammography and panoramic dental radiography devices show far lower quality than other devices. In addition, our analysis has identified the parameters that most frequently do not pass the quality tests for each type of device. Finally, we sought some correlation between quality and age of the device, but this was poorly significant. The quality index proved to be a useful tool providing an overview of the physical conditions of radiological devices. By selecting adequate QI threshold values for, it also helps to decide whether a given device should be upgraded or replaced. The identification of critical parameters for each type of device may be used to improve the definition of the QI by attributing greater weights to critical parameters, so as to better address the maintenance of radiological devices.

  3. Medical Devices; Clinical Chemistry and Clinical Toxicology Devices; Classification of the Organophosphate Test System. Final order.

    Science.gov (United States)

    2017-10-18

    The Food and Drug Administration (FDA or we) is classifying the organophosphate test system into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the organophosphate test system's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  4. Medical Devices; Hematology and Pathology Devices; Classification of a Cervical Intraepithelial Neoplasia Test System. Final order.

    Science.gov (United States)

    2018-01-03

    The Food and Drug Administration (FDA or we) is classifying the cervical intraepithelial neoplasia (CIN) test system into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the CIN test system's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  5. Novel Simple Insulin Delivery Device Reduces Barriers to Insulin Therapy in Type 2 Diabetes

    Science.gov (United States)

    Hermanns, Norbert; Lilly, Leslie C.; Mader, Julia K.; Aberer, Felix; Ribitsch, Anja; Kojzar, Harald; Warner, Jay; Pieber, Thomas R.

    2015-01-01

    Background: The PaQ® insulin delivery system is a simple-to-use patch-on device that provides preset basal rates and bolus insulin on demand. In addition to feasibility of use, safety, and efficacy (reported elsewhere), this study analyzed the impact of PaQ on patient-reported outcomes, including barriers to insulin treatment, diabetes-related distress, and attitudes toward insulin therapy in patients with type 2 diabetes on a stable multiple daily injection (MDI) regimen. Methods: This single-center, open-label, single-arm study comprised three 2-week periods: baseline (MDI), transition from MDI to PaQ, and PaQ treatment. Validated questionnaires were administered during the baseline and PaQ treatment periods: Barriers to Insulin Treatment questionnaire (BIT), Insulin Treatment Appraisal Scale (ITAS), and Problem Areas in Diabetes scale (PAID). Results: Eighteen patients (age 59 ± 5 years, diabetes duration 15 ± 7 years, 21% female, HbA1c 7.7 ± 0.7%) completed the questionnaires. There was a strong, significant effect of PaQ use in mean BIT total scores (difference [D] = −5.4 ± 0.7.7, P = .01, effect size [d] = 0.70). Patients perceived less stigmatization by insulin injection (D = −2.2 ± 6.2, P = .18, d = 0.35), increased positive outcome (D = 1.9 ± 6.6, P = .17, d = 0.29), and less fear of injections (1.3 ± 4.8, P = .55, d = 0.28). Mean change in ITAS scores after PaQ device use showed a nonsignificant improvement of 1.71 ± 5.63 but moderate effect size (d = 0.30, P = .14). No increase in PAID scores was seen. Conclusions: The results and moderate to large effects sizes suggest that PaQ device use has beneficial and clinically relevant effects to overcoming barriers to and negative appraisal of insulin treatment, without increasing other diabetes-related distress. PMID:25670847

  6. Rapid determination of nanowires electrical properties using a dielectrophoresis-well based system

    Science.gov (United States)

    Constantinou, Marios; Hoettges, Kai F.; Krylyuk, Sergiy; Katz, Michael B.; Davydov, Albert; Rigas, Grigorios-Panagiotis; Stolojan, Vlad; Hughes, Michael P.; Shkunov, Maxim

    2017-03-01

    The use of high quality semiconducting nanomaterials for advanced device applications has been hampered by the unavoidable growth variability of electrical properties of one-dimensional nanomaterials, such as nanowires and nanotubes, thus highlighting the need for the characterization of efficient semiconducting nanomaterials. In this study, we demonstrate a low-cost, industrially scalable dielectrophoretic (DEP) nanowire assembly method for the rapid analysis of the electrical properties of inorganic single crystalline nanowires, by identifying key features in the DEP frequency response spectrum from 1 kHz to 20 MHz in just 60 s. Nanowires dispersed in anisole were characterized using a three-dimensional DEP chip (3DEP), and the resultant spectrum demonstrated a sharp change in nanowire response to DEP signal in 1-20 MHz frequency range. The 3DEP analysis, directly confirmed by field-effect transistor data, indicates that nanowires of higher quality are collected at high DEP signal frequency range above 10 MHz, whereas lower quality nanowires, with two orders of magnitude lower current per nanowire, are collected at lower DEP signal frequencies. These results show that the 3DEP platform can be used as a very efficient characterization tool of the electrical properties of rod-shaped nanoparticles to enable dielectrophoretic selective deposition of nanomaterials with superior conductivity properties.

  7. Chemical and physical passivation of type II strained-layer superlattice devices by means of thiolated self-assembled monolayers and polymer encapsulates

    Science.gov (United States)

    Henry, Nathan C.; Knorr, Daniel B.; Williams, Kristen S.; Baril, Neil; Nallon, Eric; Lenhart, Joseph L.; Andzelm, Jan W.; Pellegrino, Joseph; Tidrow, Meimei; Cleveland, Erin; Bandara, Sumith

    2015-05-01

    The efficacy of solution deposition of thiolated self-assembled monolayers (SAMs) has been explored for the purpose of passivating III-V type II superlattice (T2SL) photodetectors, more specifically a p-type heterojunction device. Sulfur passivation has previously been achieved on T2SL devices. However, degradation over time, temperature sensitivity and inconsistent reproducibility necessitate a physical encapsulate that can chemically bond to the chemical passivant. Thus, this research investigates two passivation methods, surface passivation with a thiol monolayer and passivation with a polymer encapsulant with a view toward future combination of these techniques. Analysis of the physical and chemical condition of the surface prior to deposition assisted in the development of ideal processes for optimized film quality. Successful deposition was facilitated by in situ oxide removal. Various commercially available functional (cysteamine) and non-functional (alkane) thiolated monolayers were investigated. Dark current was reduced by 3 orders of magnitude and achieved negligible surface leakage at low bias levels. The lowest dark current result, 7.69 × 10-6 A/cm2 at 50 mV, was achieved through passivation with cysteamine.

  8. Nuclear fuel shipping inspection device

    International Nuclear Information System (INIS)

    Takahashi, Toshio; Hada, Koji.

    1988-01-01

    Purpose: To provide an nuclear fuel shipping inspection device having a high detection sensitivity and capable of obtaining highly reliable inspection results. Constitution: The present invention concerns a device for distinguishing a fuel assembly having failed fuel rods in LMFBR type reactors. Coolants in a fuel assembly to be inspected are collected by a sampling pipeway and transferred to a filter device. In the filter device, granular radioactive corrosion products (CP) in the coolants are captured, to reduce the background. The coolants, after being passed through the filter device, are transferred to an FP catching device and gamma-rays of iodine and cesium nuclides are measured in FP radiation measuring device. Subsequently, the coolants transferred to a degasing device to separate rare gas FP in the coolants from the liquid phase. In a case if rare gas fission products are detected by the radiation detector, it means that there is a failed fuel rod in the fuel assembly to be inspected. Since the CP and the soluble FP are separated and extracted for the radioactivity measurement, the reliability can be improved. (Kamimura, M.)

  9. Solid-state devices and applications

    CERN Document Server

    Lewis, Rhys

    1971-01-01

    Solid-State Devices and Applications is an introduction to the solid-state theory and its devices and applications. The book also presents a summary of all major solid-state devices available, their theory, manufacture, and main applications. The text is divided into three sections. The first part deals with the semiconductor theory and discusses the fundamentals of semiconductors; the kinds of diodes and techniques in their manufacture; the types and modes of operation of bipolar transistors; and the basic principles of unipolar transistors and their difference with bipolar transistors. The s

  10. CIS-Type PV Device Fabrication by Novel Techniques; Phase I Annual Technical Report, 1 July 1998 - 30 June 1999

    International Nuclear Information System (INIS)

    Basol, B.M.; Halani, A.; Kapur, V.K.; Leidholm, C.R.; Norsworthy, G.; Roe, R.

    1999-01-01

    This report describes work performed by International Solar Electric Technology, Inc. (ISET) during phase I of the R and D partnership subcontract titled ''CIS-Type PV Device Fabrication by Novel Techniques.'' The objective of this program is to bring ISET's novel non-vacuum CIS technology closer to commercialization by concentrating on issues such as device-efficiency improvement, larger-bandgap absorber growth, and module fabrication. Advances made in CIS and related compound solar cell fabrication processes have clearly shown that these materials and device structures can yield power conversion efficiencies in the 15%-20% range. However, many of the laboratory results on CIS-type devices have been obtained using relatively high-cost vacuum-based deposition techniques. The present project was specifically geared toward developing a low-cost, non-vacuum ''particle deposition'' method for CIS-type absorber growth. There are four major processing steps in this technique: i) preparation of a starting powder containing all or some of the chemical species constituting CIS, ii) preparation of an ink using the starting powder, iii) deposition of the ink on a substrate in the form of a thin precursor layer, and iv) conversion of the precursor layer into a fused photovoltaic absorber through annealing steps. During this Phase I program, ISET worked on tasks that were geared toward the following goals: i) elimination of back-contact problems, ii) growth of large-bandgap absorbers, and iii) fabrication of mini-modules. As a result of the Phase I research, a Mo back-contact structure was developed that eliminated problems that resulted in poor mechanical integrity of the absorber layers. Sulfur inclusion into CIS films through high-temperature sulfurization in H2S gas was also studied. It was determined that S diffusion was a strong function of the stoichiometry of the CIS layer. Sulfur was found to diffuse rapidly through the Cu-rich films, whereas the diffusion constant was

  11. Waste classifying and separation device

    International Nuclear Information System (INIS)

    Kakiuchi, Hiroki.

    1997-01-01

    A flexible plastic bags containing solid wastes of indefinite shape is broken and the wastes are classified. The bag cutting-portion of the device has an ultrasonic-type or a heater-type cutting means, and the cutting means moves in parallel with the transferring direction of the plastic bags. A classification portion separates and discriminates the plastic bag from the contents and conducts classification while rotating a classification table. Accordingly, the plastic bag containing solids of indefinite shape can be broken and classification can be conducted efficiently and reliably. The device of the present invention has a simple structure which requires small installation space and enables easy maintenance. (T.M.)

  12. Safeguards of basic protection devices, high-protection devices, full-protection devices and school X-ray devices. Guideline for manufacturer and evaluating experts, rev. 1.0; Sicherheitsvorrichtungen von Basisschutzgeraeten, Hochschutzgeraeten, Vollschutzgeraeten und Schulroentgeneinrichtungen. Anforderungen fuer die Bauartpruefung nach der Roentgenverordnung. Leitfaden fuer Hersteller und Gutachter Rev. 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Dombrowski, Harald; Grottker, Ulrich; Pullner, Bjoern; Roettger, Annette; Zwiener, Roland

    2017-07-15

    This report describes the PTB requirements for engineered safeguards of basic-protection devices, high-protection devices, full-protection devices and school X-ray devices within the framework of type tests according to the German X-ray Ordinance. It contains detailed requirements for the hard- and software to ensure the required safety level. Especially manufacturers and evaluators of such X-ray tube assemblies are addressed.

  13. Device for supporting a toroidal coil in a toroidal type nuclear fusion device

    International Nuclear Information System (INIS)

    Kitazawa, Hakaru; Sato, Hiroshi.

    1975-01-01

    Object: To easily manufacture a center block having a strength sufficient to withstand an electromagnetic force exerted on the center of toroidal of a toroidal coil and to increase its reliability. Structure: In a device for supporting toroidal coils wherein the electromagnetic force exerted on the center of toroidal of a plurality of toroidal coils arranged in toroidal fashion, the contact surface between the toroidal coil and the center block is arranged parallel to the center axis of toroidal so as to receive the electromagnetic force exerted on the center of toroidal of the toroidal coil as the component of force in a radial direction. (Taniai, N.)

  14. Organic bistable light-emitting devices

    Science.gov (United States)

    Ma, Liping; Liu, Jie; Pyo, Seungmoon; Yang, Yang

    2002-01-01

    An organic bistable device, with a unique trilayer structure consisting of organic/metal/organic sandwiched between two outmost metal electrodes, has been invented. [Y. Yang, L. P. Ma, and J. Liu, U.S. Patent Pending, U.S. 01/17206 (2001)]. When the device is biased with voltages beyond a critical value (for example 3 V), the device suddenly switches from a high-impedance state to a low-impedance state, with a difference in injection current of more than 6 orders of magnitude. When the device is switched to the low-impedance state, it remains in that state even when the power is off. (This is called "nonvolatile" phenomenon in memory devices.) The high-impedance state can be recovered by applying a reverse bias; therefore, this bistable device is ideal for memory applications. In order to increase the data read-out rate of this type of memory device, a regular polymer light-emitting diode has been integrated with the organic bistable device, such that it can be read out optically. These features make the organic bistable light-emitting device a promising candidate for several applications, such as digital memories, opto-electronic books, and recordable papers.

  15. External shading devices for energy efficient building

    Science.gov (United States)

    Shahdan, M. S.; Ahmad, S. S.; Hussin, M. A.

    2018-02-01

    External shading devices on a building façade is an important passive design strategy as they reduce solar radiation. Although studies have proven the benefits of external shading devices, many are designed solely for aesthetic purposes without fully considering its high potential to reduce solar radiation and glare. Furthermore, explorations into shading devices by the design team are mostly left too late in the design development phases. Hence, the paper looks into the effectiveness of external shading devices on a building towards more energy efficient building. The study aims to analyse the effects of various configurations of external shading devices towards the energy consumption of a case study building based on computer simulations. This study uses Building Information Modelling (BIM) through Autodesk Revit software as simulation tool. The constant variables for the simulation are the orientation of the building, types of glazing used by the building and the internal loads of the building. Whereas, the manipulated variable is the types of shading device used. The data were sorted according to the categories and translated into a chart. Analysis of the findings indicate that shading devices with different configurations show significant results in the energy consumption and the best configuration is the egg-crate shading devices. The study recommends that the consideration for shading device as a passive design strategy needs to be developed at the early stage of the building design.

  16. Oxide bipolar electronics: materials, devices and circuits

    International Nuclear Information System (INIS)

    Grundmann, Marius; Klüpfel, Fabian; Karsthof, Robert; Schlupp, Peter; Schein, Friedrich-Leonhard; Splith, Daniel; Yang, Chang; Bitter, Sofie; Von Wenckstern, Holger

    2016-01-01

    We present the history of, and the latest progress in, the field of bipolar oxide thin film devices. As such we consider primarily pn-junctions in which at least one of the materials is a metal oxide semiconductor. A wide range of n-type and p-type oxides has been explored for the formation of such bipolar diodes. Since most oxide semiconductors are unipolar, challenges and opportunities exist with regard to the formation of heterojunction diodes and band lineups. Recently, various approaches have led to devices with high rectification, namely p-type ZnCo 2 O 4 and NiO on n-type ZnO and amorphous zinc-tin-oxide. Subsequent bipolar devices and applications such as photodetectors, solar cells, junction field-effect transistors and integrated circuits like inverters and ring oscillators are discussed. The tremendous progress shows that bipolar oxide electronics has evolved from the exploration of various materials and heterostructures to the demonstration of functioning integrated circuits. Therefore a viable, facile and high performance technology is ready for further exploitation and performance optimization. (topical review)

  17. Radiation Characterization of Commercial GaN Devices

    Science.gov (United States)

    Harris, Richard D.; Scheick, Leif Z.; Hoffman, James P.; Thrivikraman, Tushar; Jenabi, Masud; Gim, Yonggyu; Miyahira, Tetsuo

    2011-01-01

    Radiative feedback from primordial protostars and final mass of the first star Commercially available devices fabricated from GaN are beginning to appear from a number of different suppliers. Based on previous materials and prototype device studies, it is expected that these commercial devices will be quite tolerant to the types of radiation encountered in space. This expectation needs to be verified and the study described herein was undertaken for that purpose. All of the parts discussed in this report are readily available commercially. The parts chosen for study are all targeted for RF applications. Three different studies were performed: 1) a preliminary DDD/TID test of a variety of part types was performed by irradiating with 50 MeV protons, 2) a detailed DDD/TID study of one particular part type was performed by irradiating with 50 MeV protons, and 3) a SEB/SEGR test was performed on a variety of part types by irradiating with heavy ions. No significant degradation was observed in the tests performed in this study.

  18. Selective shielding device for scintiphotography

    International Nuclear Information System (INIS)

    Harper, J.W.; Kay, T.D.

    1976-01-01

    A selective shielding device to be used in combination with a scintillation camera is described. The shielding device is a substantially oval-shaped configuration removably secured to the scintillation camera. As a result of this combination scanning of preselected areas of a patient can be rapidly and accurately performed without the requirement of mounting any type of shielding paraphernalia on the patient. 1 claim, 2 drawing figures

  19. Novel Simple Insulin Delivery Device Reduces Barriers to Insulin Therapy in Type 2 Diabetes: Results From a Pilot Study

    OpenAIRE

    Hermanns, Norbert; Lilly, Leslie C.; Mader, Julia K.; Aberer, Felix; Ribitsch, Anja; Kojzar, Harald; Warner, Jay; Pieber, Thomas R.

    2015-01-01

    Background: The PaQ® insulin delivery system is a simple-to-use patch-on device that provides preset basal rates and bolus insulin on demand. In addition to feasibility of use, safety, and efficacy (reported elsewhere), this study analyzed the impact of PaQ on patient-reported outcomes, including barriers to insulin treatment, diabetes-related distress, and attitudes toward insulin therapy in patients with type 2 diabetes on a stable multiple daily injection (MDI) regimen. Methods: This singl...

  20. Health physics appraisal guidelines for fusion/confinement devices

    International Nuclear Information System (INIS)

    Neeson, P.M.

    1987-01-01

    Several types of fusion/confinement devices have been developed for a variety of research applications. The health physics considerations for these devices can vary, depending on a number of parameters. This paper presents guidelines for health physics appraisal of such devices, which can be tailored to apply to specific systems. The guidelines can also be useful for establishing ongoing health physics programs for safe operation of the devices

  1. Underwater running device

    International Nuclear Information System (INIS)

    Kogure, Sumio; Matsuo, Takashiro; Yoshida, Yoji

    1996-01-01

    An underwater running device for an underwater inspection device for detecting inner surfaces of a reactor or a water vessel has an outer frame and an inner frame, and both of them are connected slidably by an air cylinder and connected rotatably by a shaft. The outer frame has four outer frame legs, and each of the outer frame legs is equipped with a sucker at the top end. The inner frame has four inner frame legs each equipped with a sucker at the top end. The outer frame legs and the inner frame legs are each connected with the outer frame and the inner frame by the air cylinder. The outer and the inner frame legs can be elevated or lowered (or extended or contracted) by the air cylinder. The sucker is connected with a jet pump-type negative pressure generator. The device can run and move by repeating attraction and releasing of the outer frame legs and the inner frame legs alternately while maintaining the posture of the inspection device stably. (I.N.)

  2. Neutron measuring device

    International Nuclear Information System (INIS)

    Hatayama, Akiyoshi; Seki, Eiji; Kita, Yoshio; Nishitani, Takeo.

    1993-01-01

    The device of the present invention concerns measurement for neutrons in a tokamak type thermonuclear device and it can measure total amount of generated neutrons accurately throughout the operation period even if an error is caused in counted values by plasma disruption. That is, the device comprises (1) a means for detecting presence or absence of occurrence of plasma disruption and the time for the initiation of the occurrence, (2) a first data processing means for processing detection signals, (3) a means for detecting neutrons generated in plasmas and (4) a second data processing means for calculating integrated values for the number of neutrons generated from the start to the completion of electric discharge when no disruption occurs and calculating integrated values for the number of generated neutrons from the start of electric discharge to the time at the initiation of occurrence of the disruption when disruption is present. In the thus constituted device, even if an error is caused by frequent occurrence of plasma disruption, total time integrated amount of neutrons generated in the plasmas can be measured accurately. (I.S.)

  3. Marine Sanitation Devices (MSDs)

    Science.gov (United States)

    Marine sanitation devices treat or retain sewage from vessels, and have performance standards set by the EPA. This page provides information on MSDs, including who must use an MSD, states' roles, types of MSDs and standards.

  4. Hidden (end-on) patent ductus arteriosus: recognition and device closure.

    Science.gov (United States)

    Garg, Naveen; Madan, Bevunahalli Kantharaj

    2016-02-01

    Sometimes, it is difficult to visualize a patent ductus arteriosus and deploy a device in the standard lateral view because of an end-on orientation. The right anterior oblique view may be helpful by separating the ductus arteriosus from the aorta. This study was undertaken to evaluate the incidence of end-on patent ductus arteriosus and the utility of the right anterior oblique view during device closure. Aortography was performed in lateral and right anterior oblique views before, during, and after successful device deployment in 117 consecutive patients. When a ductus arteriosus was not clearly visible in the lateral view due to overlapping by the aorta, it was termed "right anterior oblique view useful". The types of patent ductus arteriosus were A, B, C, and E in 86 (73.5%), 20 (17.1%), 4 (3.4%), and 7 (6.0%) patients, respectively. An end-on ductus arteriosus was present in 24 (20.5%) patients (14 type B, 10 type A). The right anterior oblique view was useful during device closure in 15 (12.8%) cases (all end-on type). Among all cases of end-on patent ductus arteriosus, it was useful in 62.5% (most type B and a few type A). In all of these, the device appeared obliquely oriented and foreshortened in the lateral view but fully profiled in the right anterior oblique view. Recognizing an end-on patent ductus arteriosus and utilizing the right anterior oblique view simplified device closure. For ducts well-profiled in the lateral view, the right anterior oblique view is unnecessary and avoidable. © The Author(s) 2016.

  5. Studies on the Effect of Radio Frequency Field in a Cusp-Type Charge Separation Device for Direct Energy Conversion

    OpenAIRE

    HAMABE, Masaki; IZAWA, Hiroaki; TAKENO, Hiromasa; NAKAMOTO, Satoshi; ICHIMURA, Kazuya; NAKASHIMA, Yousuke

    2016-01-01

    In D-3He fusion power generation, an application of direct energy conversion is expected in which separation of charged particles is necessary. A cusp-type direct energy converter (CuspDEC) was proposed as a charge separation device, but its performance was degraded for a high density plasma. The goal of the present study is to establish an additional method to assist charge separation by using a nonlinear effect of a radio frequency (rf) electric field. Following to the previous study, we ex...

  6. Insertion of a pentacene layer into the gold/poly(methyl methacrylate)/heavily doped p-type Si/indium device leading to the modulation of resistive switching characteristics

    Science.gov (United States)

    Hung, Cheng-Chun; Lin, Yow-Jon

    2018-01-01

    In order to get a physical insight into the pentacene interlayer-modulated resistive switching (RS) characteristics, the Au/pentacene/poly(methyl methacrylate) (PMMA)/heavily doped p-type Si (p+-Si)/In and Au/PMMA/p+-Si/In devices are fabricated and the device performance is provided. The Au/pentacene/PMMA/p+-Si/In device shows RS behavior, whereas the Au/PMMA/p+-Si/In device exhibits the set/reset-free hysteresis current-voltage characteristics. The insertion of a pentacene layer is a noticeable contribution to the RS characteristic. This is because of the occurrence of carrier accumulation/depletion in the pentacene interlayer. The transition from carrier depletion to carrier accumulation (carrier accumulation to carrier depletion) in pentacene occurring under negative (positive) voltage induces the process of set (reset). The switching conduction mechanism is primarily described as space charge limited conduction according to the electrical transport properties measurement. The concept of a pentacene/PMMA heterostructure opens a promising direction for organic memory devices.

  7. Study of various n-type organic semiconductors on ultraviolet detective and electroluminescent properties of optoelectronic integrated device

    Science.gov (United States)

    Deng, Chaoxu; Shao, Bingyao; Zhao, Dan; Zhou, Dianli; Yu, Junsheng

    2017-11-01

    Organic optoelectronic integrated device (OID) with both ultraviolet (UV) detective and electroluminescent (EL) properties was fabricated by using a thermally activated delayed fluorescence (TADF) semiconductor of (4s, 6s)-2,4,5,6-tetra(9H-carbazol-9-yl)isophthalonitrile (4CzIPN) as an emitter. The effect of five kinds of n-type organic semiconductors (OSCs) on the enhancement of UV detective and EL properties of OID was systematically studied. The result shows that two orders of magnitude in UV detectivity from 109 to 1011 Jones and 3.3 folds of luminance from 2499 to 8233 cd m-2 could be achieved. The result shows that not only the difference of lowest unoccupied molecular orbital (LUMO) between active layer and OSC but also the variety of electron mobility have a significant effect on the UV detective and EL performance through adjusting electron injection/transport. Additionally, the optimized OSC thickness is beneficial to confine the leaking of holes from the active layer to cathode, leading to the decrease of dark current for high detective performance. This work provides a useful method on broadening OSC material selection and device architecture construction for the realization of high performance OID.

  8. Studies on the effect of radio frequency field in a cusp-type charge separation device for direct energy conversion

    International Nuclear Information System (INIS)

    Hamabe, Masaki; Izawa, Hiroaki; Takeno, Hiromasa; Nakamoto, Satoshi; Ichimura, Kazuya; Nakashima, Yousuke

    2016-01-01

    In D- 3 He fusion power generation, an application of direct energy conversion is expected in which separation of charged particles is necessary. A cusp-type direct energy converter (CuspDEC) was proposed as a charge separation device, but its performance was degraded for a high density plasma. The goal of the present study is to establish an additional method to assist charge separation by using a nonlinear effect of a radio frequency (rf) electric field. Following to the previous study, we experimentally examine the effect of an rf field to electron motion in a CuspDEC device. Two ring electrodes were newly installed in a CuspDEC simulator and the current flowing into the electron collector located in the line cusp region was measured on an rf field application. The significant variation in the current was found, and an improvement of the charge separation can be expected by using the phenomenon appropriately. (author)

  9. Electronic portal imaging devices

    International Nuclear Information System (INIS)

    Lief, Eugene

    2008-01-01

    The topics discussed include, among others, the following: Role of portal imaging; Port films vs. EPID; Image guidance: Elekta volume view; Delivery verification; Automation tasks of portal imaging; Types of portal imaging (Fluorescent screen, mirror, and CCD camera-based imaging; Liquid ion chamber imaging; Amorpho-silicon portal imagers; Fluoroscopic portal imaging; Kodak CR reader; and Other types of portal imaging devices); QA of EPID; and Portal dosimetry (P.A.)

  10. Radiation effects in optoelectronic devices

    International Nuclear Information System (INIS)

    Barnes, C.E.; Wiczer, J.J.

    1984-05-01

    Purpose of this report is to provide not only a summary of radiation damage studies at Sandia National Laboratories, but also of those in the literature on the components of optoelectronic systems: light emitting diodes (LEDs), laser diodes, photodetectors, optical fibers, and optical isolators. This review of radiation damage in optoelectronic components is structured according to device type. In each section, a brief discussion of those device properties relevant to radiation effects is given

  11. 49 CFR 173.340 - Tear gas devices.

    Science.gov (United States)

    2010-10-01

    ... SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.340 Tear gas devices. (a) Packagings for...) Tear gas devices may not be assembled with, or packed in the same packaging with, mechanically- or manually-operated firing, igniting, bursting, or other functioning elements unless of a type and design...

  12. Effect of ac electric field on the dynamics of a vesicle under shear flow in the small deformation regime

    Science.gov (United States)

    Sinha, Kumari Priti; Thaokar, Rochish M.

    2018-03-01

    Vesicles or biological cells under simultaneous shear and electric field can be encountered in dielectrophoretic devices or designs used for continuous flow electrofusion or electroporation. In this work, the dynamics of a vesicle subjected to simultaneous shear and uniform alternating current (ac) electric field is investigated in the small deformation limit. The coupled equations for vesicle orientation and shape evolution are derived theoretically, and the resulting nonlinear equations are handled numerically to generate relevant phase diagrams that demonstrate the effect of electrical parameters on the different dynamical regimes such as tank treading (TT), vacillating breathing (VB) [called trembling (TR) in this work], and tumbling (TU). It is found that while the electric Mason number (Mn), which represents the relative strength of the electrical forces to the shear forces, promotes the TT regime, the response itself is found to be sensitive to the applied frequency as well as the conductivity ratio. While higher outer conductivity promotes orientation along the flow axis, orientation along the electric field is favored when the inner conductivity is higher. Similarly a switch of orientation from the direction of the electric field to the direction of flow is possible by a mere change of frequency when the outer conductivity is higher. Interestingly, in some cases, a coupling between electric field-induced deformation and shear can result in the system admitting an intermediate TU regime while attaining the TT regime at high Mn. The results could enable designing better dielectrophoretic devices wherein the residence time as well as the dynamical states of the vesicular suspension can be controlled as per the application.

  13. Coordination Protocols for a Reliable Sensor, Actuator, and Device Network (SADN

    Directory of Open Access Journals (Sweden)

    Keiji Ozaki

    2008-01-01

    Full Text Available A sensor, actuator, and device network (SADN is composed of three types of nodes, which are sensor, actuator, and actuation device nodes. Sensor nodes and actuator nodes are interconnected in wireless networks as discussed in wireless sensor and actuator networks (WSANs. Actuator nodes and device nodes are interconnected in types of networks, i.e. wireless and wired network. Sensor nodes sense an physical event and send sensed values of the event to actuator nodes. An actuator node makes a decision on proper actions on receipt of sensed values and then issue the action requests to the device nodes. A device node really acts to the physical world. For example, moves a robot arms by performing the action on receipt of the action request. Messages may be lost and nodes may be faulty. Especially, messages are lost due to noise and collision in a wireless network. We propose a fully redundant model for an SADN where each of sensor, actuator, and device functions is replicated in multiple nodes and each of sensor-actuator and actuator-device communication is realized in many-to-many type of communication protocols. Even if some number of nodes are faulty, the other nodes can perform requested tasks. Here, each sensor node sends sensed values to multiple actuator nodes and each actuator node receives sensed values from multiple sensor nodes. While multiple actuator nodes communicate with multiple replica nodes of a device. Even if messages are lost and some number of nodes are faulty, device nodes can surely receive action requests required for sensed values and the actions are performed. In this paper, we discuss a type of semi-passive coordination (SPC protocol of multiple actuator nodes for multiple sensor nodes. We discuss a type of active coordination protocol for multiple actuator nodes and multiple actuation device nodes. We evaluate the SPC protocol for the sensor-actuator coordination in terms of the number of messages exchanged among

  14. Smart portable rehabilitation devices

    Directory of Open Access Journals (Sweden)

    Leahey Matt

    2005-07-01

    Full Text Available Abstract Background The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s. Methods In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Results Laboratory tests of the devices

  15. Smart portable rehabilitation devices.

    Science.gov (United States)

    Mavroidis, Constantinos; Nikitczuk, Jason; Weinberg, Brian; Danaher, Gil; Jensen, Katherine; Pelletier, Philip; Prugnarola, Jennifer; Stuart, Ryan; Arango, Roberto; Leahey, Matt; Pavone, Robert; Provo, Andrew; Yasevac, Dan

    2005-07-12

    The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s). In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Laboratory tests of the devices demonstrated that they were able to meet their design

  16. Firewood preparation devices in 1994

    International Nuclear Information System (INIS)

    Mutikainen, A.

    1994-01-01

    A review of the market situation regarding firewood preparation devices is presented. The information was collected from the answers to a mail questionnaire. The review is assumed to include all the leading manufacturers and importers. Firewood production devices were available from 26 manufacturers. The range of models amounted to over 70. These may be divided into three categories: 1. cutting devices: the most common solution being a cross-cutting circular saw. There were only a few of these on sale as it is quite easy to include a splitting device on the same frame. 2. Splitting devices: e.g. screw splitter and hydraulically powered splitter. About 20 models are available on the markets. Cross cutting and splitting devices: these are the most popular devices. A cross-cutting circular saw with screw or hydraulic splitter is the most common type. There are about 50 models available on the markets. Cross-cutting and splitting devices are often equipped with conveyor for transferring the split wood e.g. into a trailer. Chopping devices are delivered as tractor powered devices, as electric motor powered devices or as combustion engine powered devices. Some of them are equipped with a time saving feeding device enabling the next stem to be lifted into position while the previous one is being chopped. The Finnish Work Efficiency Institute's studies show that when cross-cutting and splitting of stems into pieces of 35-50 cm in length, productivity for one operator varies in between 0.8 - 3.2 m 3 /h, depending on the device and work method used. (6 refs., 1 fig., 2 tabs.)

  17. Fringing-field dielectrophoretic assembly of ultrahigh-density semiconducting nanotube arrays with a self-limited pitch

    Science.gov (United States)

    Cao, Qing; Han, Shu-Jen; Tulevski, George S.

    2014-09-01

    One key challenge of realizing practical high-performance electronic devices based on single-walled carbon nanotubes is to produce electronically pure nanotube arrays with both a minuscule and uniform inter-tube pitch for sufficient device-packing density and homogeneity. Here we develop a method in which the alternating voltage-fringing electric field formed between surface microelectrodes and the substrate is utilized to assemble semiconducting nanotubes into well-aligned, ultrahigh-density and submonolayered arrays, with a consistent pitch as small as 21±6 nm determined by a self-limiting mechanism, based on the unique field focusing and screening effects of the fringing field. Field-effect transistors based on such nanotube arrays exhibit record high device transconductance (>50 μS μm-1) and decent on current per nanotube (~1 μA per tube) together with high on/off ratios at a drain bias of -1 V.

  18. Radiometric weighing devices. Part 1 and 2

    International Nuclear Information System (INIS)

    Glaeser, M.

    1985-01-01

    Proceeding from the physical and mathematical fundamentals and from the types of radiometric weighing devices presently available, the radiation protection problems arising from the application of radiometric gages in industry and agriculture are discussed. Nuclear weighing devices have been found to be effective from economic point of view but in some cases gravimetric conveyor weighers are indispensable. Information and guidance is given especially for users of radiometric weighing devices. 91 refs., 69 figs., and 8 tabs

  19. Thermometry in dielectrophoresis chips for contact-free cell handling

    International Nuclear Information System (INIS)

    Jaeger, M S; Mueller, T; Schnelle, T

    2007-01-01

    Cell biology applications, protocols in immunology and stem cell research, require that individual cells are handled under strict control of their contacts to other cells or synthetic surfaces. Dielectrophoresis (DEP) in microfluidic chips is an established technique to investigate, group, wash, cultivate and sort cells contact-free under physiological conditions: microelectrode octode cages, versatile dielectrophoretic elements energized with radio frequency electric fields, stably trap single cells or cellular aggregates. For medical applications and cell cultivation, possible side effects of the dielectrophoretic manipulation, such as membrane polarization and Joule heating, have to be quantified. Therefore, we characterized the electric field-induced warming in dielectrophoretic cages using ohmic resistance measurements, fluorometry, liquid crystal beads, infra-red thermography and bubble size thermometry. We compare the results of these techniques with respect to the influences of voltage, electric conductivity of buffer, frequency, cage size and electrode surface. We conclude that in the culture medium thermal effects may be neglected if low voltages and an electric field-reducing phase pattern are used. Our experimental results provide explicit values for estimating the thermal effect on dielectrophoretically caged cells and show that Joule heating is best minimized by optimizing the cage geometry and reducing the buffer conductivity. The results may additionally serve to evaluate and improve theoretical predictions on field-induced effects. Based on present-day chip processing possibilities, DEP is well suited for the manipulation of cells

  20. Reactor container cooling device

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Koji; Kinoshita, Shoichiro

    1995-11-10

    The device of the present invention efficiently lowers pressure and temperature in a reactor container upon occurrence of a severe accident in a BWR-type reactor and can cool the inside of the container for a long period of time. That is, (1) pipelines on the side of an exhaustion tower of a filter portion in a filter bent device of the reactor container are in communication with pipelines on the side of a steam inlet of a static container cooling device by way of horizontal pipelines, (2) a back flow check valve is disposed to horizontal pipelines, (3) a steam discharge valve for a pressure vessel is disposed closer to the reactor container than the joint portion between the pipelines on the side of the steam inlet and the horizontal pipelines. Upon occurrence of a severe accident, when the pressure vessel should be ruptured and steams containing aerosol in the reactor core should be filled in the reactor container, the inlet valve of the static container cooling device is closed. Steams are flown into the filter bent device of the reactor container, where the aerosols can be removed. (I.S.).

  1. Computer Independent Data Transfer Device

    Directory of Open Access Journals (Sweden)

    Darshana Rarath

    2017-07-01

    Full Text Available In today’s era, transferring data among distinct storage devices has become one of the tasks which are done most frequently. In order to make data and information omnipresent, it needs to be shared anywhere and anytime. However the reliance of user on a PC or laptop for the same is not efficient. This paper is about the innovative way to overcome this restriction. This paper discusses the development of a portable device with the use of wired and wireless communication applications to share data and information among distinct storage devices without relying on a PC or a laptop. The proposed device is compact, comprises of a touch screen, power source and is capable of transferring all types of files. Hence, it eliminates the dependence on a PC or a laptop for transferring data.

  2. Organic material reducing device in nuclear power plant

    International Nuclear Information System (INIS)

    Minakata, Noriyuki; Takada, Takao

    1998-01-01

    A total organic carbon (TOC) removing device is disposed between a filtration device and a desalting device or between a condensator and the desalting device disposed to a radioactive liquid waste processing facility or a condensate cleaning system of a BWR type nuclear reactor. Since the removing ratio of the TOC removing device is generally high if impurities are not contained, and ionic ingredients are formed after decomposition, TOC can be decomposed and removed more efficiently and removal in a short period of time can be expected by disposing the TOC device downstream of the filtration device or a condensator to be disposed instead of the filtration device and upstream of the desalting device. Then, further enhanced effect can be expected, if two series of the TOC removing line and the bypass line are disposed between the filtration device or the condensator and the desalting device so as to enable selection of processed liquids. (T.M.)

  3. Cell jammers, GPS jammers, and other jamming devices.

    Science.gov (United States)

    2012-10-15

    We caution consumers that it is against the law to use a cell or GPS jammer or any other type of device that blocks, : jams or interferes with authorized communications, as well as to import, advertise, sell, or ship such a device. The : FCC Enforcem...

  4. Internet-based Advertising Claims and Consumer Reasons for Using Electronic Cigarettes by Device Type in the US.

    Science.gov (United States)

    Pulvers, Kim; Sun, Jessica Y; Zhuang, Yue-Lin; Holguin, Gabriel; Zhu, Shu-Hong

    2017-10-01

    Important differences exist between closed-system and open-system e-cigarettes, but it is unknown whether online companies are marketing these devices differently and whether consumer reasons for using e-cigarettes vary by device type. This paper compares Internet-based advertising claims of closed- versus open-system products, and evaluates US consumers' reasons for using closed- versus open-system e-cigarettes. Internet sites selling exclusively closed (N = 130) or open (N = 129) e-cigarettes in December 2013-January 2014 were coded for advertising claims. Current users (≥18 years old) of exclusively closed or open e-cigarettes (N = 860) in a nationally representative online survey in February-March 2014 provided their main reason for using e-cigarettes. Internet sites that exclusively sold closed-system e-cigarettes were more likely to make cigarette-related claims such as e-cigarettes being healthier and cheaper than cigarettes (ps < .0001) compared to sites selling open systems. Many sites implied their products could help smokers quit. Exclusive users of both systems endorsed cessation as their top reason. Closed-system users were more likely to report their reason as "use where smoking is banned." Although promotion of e-cigarettes as cessation aids is prohibited, consumers of both systems endorsed smoking cessation as their top reason for using e-cigarettes.

  5. Radiographic film digitizing devices

    International Nuclear Information System (INIS)

    McFee, W.H.

    1988-01-01

    Until recently, all film digitizing devices for use with teleradiology or picture archiving and communication systems used a video camera to capture an image of the radiograph for subsequent digitization. The development of film digitizers that use a laser beam to scan the film represents a significant advancement in digital technology, resulting in improved image quality compared with video scanners. This paper discusses differences in resolution, efficiency, reliability, and the cost between these two types of devices. The results of a modified receiver operating characteristic comparison study of a video scanner and a laser scanner manufactured by the same company are also discussed

  6. A Quick-responsive DNA Nanotechnology Device for Bio-molecular Homeostasis Regulation.

    Science.gov (United States)

    Wu, Songlin; Wang, Pei; Xiao, Chen; Li, Zheng; Yang, Bing; Fu, Jieyang; Chen, Jing; Wan, Neng; Ma, Cong; Li, Maoteng; Yang, Xiangliang; Zhan, Yi

    2016-08-10

    Physiological processes such as metabolism, cell apoptosis and immune responses, must be strictly regulated to maintain their homeostasis and achieve their normal physiological functions. The speed with which bio-molecular homeostatic regulation occurs directly determines the ability of an organism to adapt to conditional changes. To produce a quick-responsive regulatory system that can be easily utilized for various types of homeostasis, a device called nano-fingers that facilitates the regulation of physiological processes was constructed using DNA origami nanotechnology. This nano-fingers device functioned in linked open and closed phases using two types of DNA tweezers, which were covalently coupled with aptamers that captured specific molecules when the tweezer arms were sufficiently close. Via this specific interaction mechanism, certain physiological processes could be simultaneously regulated from two directions by capturing one biofactor and releasing the other to enhance the regulatory capacity of the device. To validate the universal application of this device, regulation of the homeostasis of the blood coagulant thrombin was attempted using the nano-fingers device. It was successfully demonstrated that this nano-fingers device achieved coagulation buffering upon the input of fuel DNA. This nano-device could also be utilized to regulate the homeostasis of other types of bio-molecules.

  7. Electromagnetic device of the safety screw-nut type

    International Nuclear Information System (INIS)

    Defaucheux, Jean; Guedj, Freddy.

    1981-01-01

    System providing for the vertical displacement of nuclear reactor control rods in a non-magnetic and cylindrical leak tight containment. This device is composed of a stator located around the upper part of the containment and, inside this containment, a rotor also in the upper part of this containment, which is free in axial translation along its shaft which it drives rotationally but which is fixed in translation. This shaft drives a threaded rod working in conjunction with a nut and able to slide vertically without turning inside the containment and supporting the reactor control rods. When the stator is not powered, the threaded rod and nut assembly falls to the bottom of the containment and may be easily raised by powering the stator [fr

  8. Proton irradiation effects in silicon devices

    Energy Technology Data Exchange (ETDEWEB)

    Simoen, E; Vanhellemont, J; Alaerts, A [IMEC, Leuven (Belgium); and others

    1997-03-01

    Proton irradiation effects in silicon devices are studied for components fabricated in various substrates in order to reveal possible hardening effects. The degradation of p-n junction diodes increases in first order proportionally with the fluence, when submitted to 10 MeV proton irradiations in the range 5x10{sup 9} cm{sup -2} to 5x10{sup 11} cm{sup -2}. The damage coefficients for both p- and n-type Czochralski, Float-Zone and epitaxial wafers are reported. Charge-Coupled Devices fabricated in a 1.2 {mu}m CCD-CMOS technology are shown to be quite resistant to 59 MeV H{sup +} irradiations, irrespective of the substrate type. (author)

  9. A Case of Ruptured Blood Blister-like Aneurysm Treated with Pipeline Embolization Device: Clinical Significance of Fetal-type Posterior Communicating Artery.

    Science.gov (United States)

    Park, Ki-Su; Kang, Dong-Hun; Son, Won-Soo; Park, Jaechan; Kim, Young-Sun; Kim, Byung Moon

    2017-03-01

    Blood-blister like aneurysms (BBAs) are challenging lesions because of their wide fragile neck. Flow-diverting stents (FDSs), such as the Pipeline Embolization Device (PED), have been applied to treat BBAs less amenable to more established techniques of treatment. However, the use of FDSs, including the PED, in acute subarachnoid hemorrhage (SAH) still remains controversial. We report a case of aneurysm regrowth following PED application for a ruptured BBA that overlapped the origin of the dominant posterior communicating artery (PCoA), which was successfully treated after coil trapping of the origin of the fetal-type PCoA. And, we discuss the clinical significance of the fetal-type PCoA communicating with a BBA in terms of PED failure.

  10. Mobile Device Impairment ... Similar Problems, Similar Solutions?

    Science.gov (United States)

    Harper, Simon; Yesilada, Yeliz; Chen, Tianyi

    2011-01-01

    Previous studies have defined a new type of impairment in which an able-bodied user's behaviour is impaired by both the characteristics of a device and the environment in which it is used. This behavioural change is defined as a situationally-induced impairment and is often associated with small devices used in a mobile setting or constrained…

  11. Radiographic appearances of uncommon paediatric implants and devices

    Energy Technology Data Exchange (ETDEWEB)

    Urquia, Arlen; Watson, Tom A.; Arthurs, Owen J. [Great Ormond Street Hospital NHS Foundation Trust, Department of Radiology, London (United Kingdom)

    2015-06-15

    As childhood survival of chronic illness improves, long-term implanted devices will be encountered more frequently in routine radiology. In our paediatric tertiary referral hospital, we have come across several types of implanted devices that were not confidently recognised or identified by front-line staff and were often only identified by discussion with the patient, family or clinical team. This pictorial review highlights the appearance of nonvascular devices on paediatric radiographs in order to help clinicians identify the most frequent complications and to improve awareness of these important devices. (orig.)

  12. CT diagnosis of brain tumor types with the aid of a new, CT-controlled stereotactical device

    International Nuclear Information System (INIS)

    Huk, W.

    1980-01-01

    The hitherto unparalleled information quality of computerized tomography elicited hopes that it might also be possible to differentiate cerebral tumors according to their histologic character and degree of malignity. The present work proposes to investigate whether CT information can be useful in the diagnosis of types of brain tumors. A first part contains a critical analysis of CT findings as to their specific information value and a comparison with the possibilities previously offered by neuroradiology. In a second part, and as a consequence of the investigations in Part I, a newly developed stereotactical procedure is described combining the capacity of CT for precise location with the accuracy of aim of a stereotactical device so that cerebral proliferations evading other diagnostical attempts can be histologically cleared up. (orig./MG) [de

  13. Spin-splitting in p-type Ge devices

    Energy Technology Data Exchange (ETDEWEB)

    Holmes, S. N., E-mail: s.holmes@crl.toshiba.co.uk; Newton, P. J.; Llandro, J.; Mansell, R.; Barnes, C. H. W. [Cavendish Laboratory, Department of Physics, University of Cambridge, J. J. Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Morrison, C.; Myronov, M. [Department of Physics, University of Warwick, Coventry CV4 7AL (United Kingdom)

    2016-08-28

    Compressively strained Ge quantum well devices have a spin-splitting in applied magnetic field that is entirely consistent with a Zeeman effect in the heavy hole valence band. The spin orientation is determined by the biaxial strain in the quantum well with the relaxed SiGe buffer layers and is quantized in the growth direction perpendicular to the conducting channel. The measured spin-splitting in the resistivity ρ{sub xx} agrees with the predictions of the Zeeman Hamiltonian where the Shubnikov-deHaas effect exhibits a loss of even filling factor minima in the resistivity ρ{sub xx} with hole depletion from a gate field, increasing disorder or increasing temperature. There is no measurable Rashba spin-orbit coupling irrespective of the structural inversion asymmetry of the confining potential in low p-doped or undoped Ge quantum wells from a density of 6 × 10{sup 10} cm{sup −2} in depletion mode to 1.7 × 10{sup 11} cm{sup −2} in enhancement.

  14. Thermal shielding device in LMFBR type reactors

    International Nuclear Information System (INIS)

    Nakamura, Hiroshi.

    1985-01-01

    Purpose: To improve the soundness and earthquake proofness of mounting structures to a reactor vessel in a thermal shielding device comprising a plurality of tightly closed casings evacuated or shield with heat insulation gases, by reducing the wall thickness and weight of the casing. Constitution: the thermal shielding body comprises tightly closed casings and compressing core materials for preventing the deformation of the casings. The tightly closed casing is in the shape of a hollow vessel, completely sealed in gastight manner, and evacuated or sealed with heat insulation gases at a low pressure of about less than 0.5 kg/cm 2 G, such that the inner pressure is lower than the outer pressure. Compressing core materials made of porous metals or porous ceramics are contained to the inside of the casing. In this way, the wall thickness of the tightly closed casing can be reduced significantly as compared with the conventional case, whereby the mounting work on the site to the reactor container on the field can remarkably be improved and high reliability can be maintained at the mounting portion. (Kamimura, M.)

  15. Radioactive gas storage device

    International Nuclear Information System (INIS)

    Seki, Eiji; Kobayashi, Yoshihiro.

    1989-01-01

    The present invention concerns a device of ionizing radioactive gases to be processed in gaseous nuclear fission products in nuclear fuel reprocessing plants, etc., and injecting them into metal substrates for storage. The device comprises a vessel for a tightly closed type outer electrode in which gases to be processed are introduced, an electrode disposed to the inside of the vessel and the target material, a high DC voltage power source for applying high voltage to the electrodes, etc. There are disposed a first electric discharging portion for preparting discharge plasma for ion injection of different electrode distance and a second electric discharging portion for causing stable discharge between the vessel and the electrode. The first electric discharging portion for the ion injection provides an electrode distance suitable to acceleration sputtering and the second electric discharging portion is used for stable discharge. Accordingly, if the gas pressure in the radioactive gas storage device is reduced by the external disturbance, etc., since the second electric discharging portion satisfies the electric discharging conditions, the device can continue electric discharge. (K.M.)

  16. Semiconductor device and method of manufacturing the same

    NARCIS (Netherlands)

    2009-01-01

    The invention relates to a semiconductor device (10) with a semiconductor body (12) comprising a bipolar transistor with an emitter region, a base region and a collector region (1, 2, 3) of, respectively, a first conductivity type, a second conductivity type opposite to the first conductivity type,

  17. Treatment of sleep-disordered breathing with positive airway pressure devices: technology update.

    Science.gov (United States)

    Johnson, Karin Gardner; Johnson, Douglas Clark

    2015-01-01

    Many types of positive airway pressure (PAP) devices are used to treat sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. These include continuous PAP, autoadjusting CPAP, bilevel PAP, adaptive servoventilation, and volume-assured pressure support. Noninvasive PAP has significant leak by design, which these devices adjust for in different manners. Algorithms to provide pressure, detect events, and respond to events vary greatly between the types of devices, and vary among the same category between companies and different models by the same company. Many devices include features designed to improve effectiveness and patient comfort. Data collection systems can track compliance, pressure, leak, and efficacy. Understanding how each device works allows the clinician to better select the best device and settings for a given patient. This paper reviews PAP devices, including their algorithms, settings, and features.

  18. Medical Devices; Obstetrical and Gynecological Devices; Classification of the Pressure Wedge for the Reduction of Cesarean Delivery. Final order.

    Science.gov (United States)

    2017-12-28

    The Food and Drug Administration (FDA or we) is classifying the pressure wedge for the reduction of cesarean delivery into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the pressure wedge for the reduction of cesarean delivery's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  19. Novel wearable-type biometric devices based on skin tissue optics with multispectral LED-photodiode matrix

    Science.gov (United States)

    Jo, Young Chang; Kim, Hae Na; Kang, Jae Hwan; Hong, Hyuck Ki; Choi, Yeon Shik; Jung, Suk Won; Kim, Sung Phil

    2017-04-01

    In this study, we examined the possibility of using a multispectral skin photomatrix (MSP) module as a novel biometric device. The MSP device measures optical patterns of the wrist skin tissue. Optical patterns consist of 2 × 8 photocurrent intensities of photodiode arrays, which are generated by optical transmission and diffuse reflection of photons from LED light sources with variable wavelengths into the wrist skin tissue. Optical patterns detected by the MSP device provide information on both the surface and subsurface characteristics of the human skin tissue. We found that in the 21 subjects we studied, they showed their unique characteristics, as determined using several wavelengths of light. The experimental results show that the best personal identification accuracy can be acquired using a combination of infrared light and yellow light. This novel biometric device, the MSP module, exhibited an excellent false acceptance rate (FAR) of 0.3% and a false rejection rate (FRR) of 0.0%, which are better than those of commercialized biometric devices such as a fingerprint biometric system. From these experimental results, we found that people exhibit unique optical patterns of their inner-wrist skin tissue and this uniqueness could be used for developing novel high-accuracy personal identification devices.

  20. Economic analysis of using above ground gas storage devices for compressed air energy storage system

    Science.gov (United States)

    Liu, Jinchao; Zhang, Xinjing; Xu, Yujie; Chen, Zongyan; Chen, Haisheng; Tan, Chunqing

    2014-12-01

    Above ground gas storage devices for compressed air energy storage (CAES) have three types: air storage tanks, gas cylinders, and gas storage pipelines. A cost model of these gas storage devices is established on the basis of whole life cycle cost (LCC) analysis. The optimum parameters of the three types are determined by calculating the theoretical metallic raw material consumption of these three devices and considering the difficulties in manufacture and the influence of gas storage device number. The LCCs of the three types are comprehensively analyzed and compared. The result reveal that the cost of the gas storage pipeline type is lower than that of the other two types. This study may serve as a reference for designing large-scale CAES systems.

  1. Asymmetric devices based on carbon nanotubes for terahertz-range radiation detection

    Energy Technology Data Exchange (ETDEWEB)

    Fedorov, G. E., E-mail: gefedorov@mail.ru; Stepanova, T. S.; Gazaliev, A. Sh.; Gaiduchenko, I. A.; Kaurova, N. S.; Voronov, B. M.; Goltzman, G. N. [Moscow State Pedagogical University (Russian Federation)

    2016-12-15

    Various asymmetric detecting devices based on carbon nanotubes (CNTs) are studied. The asymmetry is understood as inhomogeneous properties along the conducting channel. In the first type of devices, an inhomogeneous morphology of the CNT grid is used. In the second type of devices, metals with highly varying work functions are used as the contact material. The relation between the sensitivity and detector configuration is analyzed. Based on the data obtained, approaches to the development of an efficient detector of terahertz radiation, based on carbon nanotubes are proposed.

  2. Guide to state-of-the-art electron devices

    CERN Document Server

    2013-01-01

    Concise, high quality and comparative overview of state-of-the-art electron device development, manufacturing technologies and applications Guide to State-of-the-Art Electron Devices marks the 60th anniversary of the IEEE Electron Devices Committee and the 35th anniversary of the IEEE Electron Devices Society, as such it defines the state-of-the-art of electron devices, as well as future directions across the entire field. Spans full range of electron device types such as photovoltaic devices, semiconductor manufacturing and VLSI technology and circuits, covered by IEEE Electron and Devices Society Contributed by internationally respected members of the electron devices community A timely desk reference with fully-integrated colour and a unique lay-out with sidebars to highlight the key terms Discusses the historical developments and speculates on future trends to give a more rounded picture of the topics covered A valuable resource R&D managers; engineers in the semiconductor industry; applied scientists...

  3. Study of device of electron-ion treatment of mother baking yeasts

    International Nuclear Information System (INIS)

    Ostapenkov, A.M.; Merinov, N.S.; Nazarov, V.N.; Balan, E.L.

    1980-01-01

    Devices for electron- ion treatment of mother baking yeasts are considered and classified by the way of aerions removal from the ionization zone: the first ones - by means of the electric field, the other - by air directed flux. Devices of the first type require high voltage - 20-60 kV. Electrodynamic ion generator has been applied as a device of the second type; considered is its construction, principal of operation, given are diagrams of ion flux dependence. The methods of process calculations in the generator and experimental results are presented. The main advantage of the generator of the second type is operation at low (3-5 kV) voltages. It is shown, that the yeast growth module can achieve 36% at essential increase of biomass when using these yeasts as sowing. The device can be used for biostimulation and antisepting of food raw materials

  4. Fraxelated radiofrequency device for acne scars

    Science.gov (United States)

    Rao, Babar K.; Khokher, Sairah

    2012-09-01

    Acne scars can be improved with various treatments such as topical creams, chemical peels, dermal fillers, microdermabrasion, laser, and radiofrequency devices. Some of these treatments especially lasers and deep chemical peels can have significant side effects such as post inflammatory hyperpigmentation in darker skin types. Fraxelated RF Laser devices have been reported to have lower incidence of side effects in all skin phototypes. Nine patients between ages 18 and 35 of various skin phototypes were selected from a private practice and treated with a RF fraxelated device (E-matrix) for acne scars. Outcomes were measured by physician observation, subjective feedback received by patients, and comparison of before and after photographs. In this small group of patients with various skin phototypes, fraxelated radiofrequency device improved acne scars with minimal side effects and downtime.

  5. Rapid fabrication of three-dimensional structures for dielectrophoretic sorting of lipid-containing organisms

    International Nuclear Information System (INIS)

    Schor, Alisha R; Buie, Cullen R

    2016-01-01

    In this work, we demonstrate a microfluidic particle sorter consisting of three-dimensional, conducting microposts. Our sorter uses dielectrophoresis (DEP) to sort high- and low-lipid phenotypes of the yeast Yarrowia lipolytica . Y. lipolytica is one of the many microorganisms being explored as a hydrocarbon source for biodiesel, Omega-3 additives, and other products derived from fatty acids. A rapid, non-destructive, lipid-based sorting tool would accelerate the commercialization of these products. Our device consists of an array of 105, 25 μ m wide gold microposts that span the height of a 15 μ m channel. This array generates an electric field in a microfluidic device that is uniform through the channel height, but has a custom-shaped non-uniformity in the horizontal directions. This is crucial in order to achieve continuous sorting using DEP, as it ensures all cells are exposed to the same conditions throughout the channel height. By using very low currents (100 μ A), we are able to electroplate these post arrays in fewer than 15 min. This is an order of magnitude improvement over previous reports of electroplated microstructures. With an applied signal of 250 MHz, 2.6 V pp in our device, we separate a heterogeneous population with a purity of 97.8% in the low-lipid stream and 71.4% in the high-lipid stream. The high-lipid stream purity can be improved by adjusting the spacing of the array. This unique protocol for the rapid fabrication of 3D microstructures has enabled the creation of a non-invasive sorting tool for genetically engineered, lipid-producing organisms. The ability to screen organisms based on lipid content will alleviate one of the major bottlenecks in commercialization of microbial biofuels. (paper)

  6. X-ray radiation detectors of 'scintillator-photoreceiving device type' for industrial digital radiography with improved spatial resolution

    International Nuclear Information System (INIS)

    Ryzhykov, V.D.; Lysetska, O.K.; Opolonin, O.D.; Kozin, D.N.

    2003-01-01

    Main types of photo receivers used in X-ray digital radiography systems are luminescent screens that transfer the optical image onto charge collection instruments, which require cooling, and semiconductor silicon detectors, which limit the contrast sensitivity. We have developed and produced X-ray radiation detectors of 'scintillator-photoreceiving device' (S-PRD) type, which are integrally located on the inverse side of the photodiode (PD). The receiving-converting circuit (RCC) is designed for data conversion into digital form and their input into PC. Software is provided for RCC control and image visualization. Main advantages of these detectors are high industrial resolution (3-5 line pairs per mm), detecting activity up to 20 μm, controlled sensitivity, low weight and small size, imaging low (0.1-0.3 mrad) object dose in real time. In this work, main characteristics of 32-, 64- and 1024-channel detectors of S-PRD type were studied and compared for X-ray sensitivity with S-PD detectors. Images of the tested objects have been obtained. Recommendations are given on the use of different scintillation materials, depending upon the purpose of a digital radiographic system. The detectors operate in a broad energy range of ionizing radiation, hence the size of the controlled object is not limited. The system is sufficiently powerful to ensure frontal (through two walls) observation of pipelines with wall thickness up to 10 cm

  7. Shroud brushing device

    International Nuclear Information System (INIS)

    Sakamaki, Kazuo; Takabayashi, Jun-ichi.

    1996-01-01

    A roller screw is assembled at an axial center of the inside of a device main body. A nut is assembled to the axial center of the roller screw secured so as not to be rotated, and a base is integrally connected to the nut. An air cylinder is pivoted to the base by a pin, and an arm is disposed to a piston rod of the air cylinder. The top end of the arm is secured to a motor case, and a brush is rotated by an electric motor in the motor case. The device main body is suspended into the reactor pressure vessel of a BWR type reactor, and seated on the upper surface of a fuel support metal fitting. The roller screw is rotated to move vertically the arm by way of the nut and the base. The device main body is rotated to rotate the arm. The arm is extended and then the electric motor is driven to rotate the brush thereby polishing the inner surface of the shroud. (I.N.)

  8. Shroud brushing device

    Energy Technology Data Exchange (ETDEWEB)

    Sakamaki, Kazuo; Takabayashi, Jun-ichi

    1996-07-12

    A roller screw is assembled at an axial center of the inside of a device main body. A nut is assembled to the axial center of the roller screw secured so as not to be rotated, and a base is integrally connected to the nut. An air cylinder is pivoted to the base by a pin, and an arm is disposed to a piston rod of the air cylinder. The top end of the arm is secured to a motor case, and a brush is rotated by an electric motor in the motor case. The device main body is suspended into the reactor pressure vessel of a BWR type reactor, and seated on the upper surface of a fuel support metal fitting. The roller screw is rotated to move vertically the arm by way of the nut and the base. The device main body is rotated to rotate the arm. The arm is extended and then the electric motor is driven to rotate the brush thereby polishing the inner surface of the shroud. (I.N.)

  9. Enhanced low dose rate radiation effect test on typical bipolar devices

    International Nuclear Information System (INIS)

    Liu Minbo; Chen Wei; Yao Zhibin; He Baoping; Huang Shaoyan; Sheng Jiangkun; Xiao Zhigang; Wang Zujun

    2014-01-01

    Two types of bipolar transistors and nine types bipolar integrated circuit were selected in the irradiation experiment at different "6"0Co γ dose rate. The base current of bipolar transistor and input bias current of amplifier and comparator was measured, low dose enhance factor of test device was obtained. The results show that bipolar device have enhanced low dose rate sensitivity, enhancement factor of bipolar integrated circuit was bigger than that of transistor, and enhanced low dose rate sensitivity greatly varied with different structure and process of bipolar device. (authors)

  10. Fuel exchange device for FBR type reactor

    International Nuclear Information System (INIS)

    Onuki, Koji.

    1993-01-01

    The device of the present invention can provide fresh fuels with a rotational angle aligned with the direction in the reactor core, so that the fresh fuels can be inserted being aligned with apertures of the reactor core even if a self orientation mechanism should fail to operate. That is, a rotational angle detection means (1) detects the rotational angle of fresh fuels before insertion to the reactor core. A fuel rotational angle control means (2) controls the rotational angle of the fresh fuels by comparing the detection result of the means (1) and the data for the insertion position of the reactor core. A fuel rotation means (3) compensates the rotational angel of the fresh fuels based on the control signal from the means (2). In this way, when the fresh fuels are inserted to the reactor core, the fresh fuels set at the same angle as that for the aperture of the reactor core. Accordingly, even if the self orientation mechanism should not operate, the fresh fuels can be inserted smoothly. As a result, it is possible to save loss time upon fuel exchange and mitigate operator's burden during operation. (I.S.)

  11. The impact of flavour, device type and warning messages on youth preferences for electronic nicotine delivery systems: evidence from an online discrete choice experiment.

    Science.gov (United States)

    Shang, Ce; Huang, Jidong; Chaloupka, Frank J; Emery, Sherry L

    2017-11-02

    To examine the impact of flavour, device type and health warning messages on youth preference for electronic nicotine delivery systems (ENDS), and to provide evidence and data to inform the Food and Drug Administration's potential regulatory actions on ENDS. An online discrete choice experiment was conducted in September 2015. Each participant was given nine choice sets and asked to choose one out of two alternative ENDS products, with varying characteristics in three attributes (flavour, device type and warning message). The impact of the attributes on the probability of choosing ENDS was analysed using conditional and nested logit regressions, controlling for individual sociodemographic characteristics and current smoking status. A general population sample of 515 participants (50 ever-users and 465 never-users of ENDS) aged 14-17 years were recruited to complete the experiment using an online panel. Fruit/sweets/beverage flavours significantly increase the probability of choosing ENDS among youth (pe-cigarettes, increase (p<0.05) the probability of choosing ENDS among adolescent never-users. Warning messages reduce (p<0.01) the probability of choosing ENDS among never-users. Restricting fruit/sweets/beverage flavours in ENDS, regulating modifiable vaping devices and adopting strong health warning messages may reduce the uptake of ENDS among youth. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. TongueToSpeech (TTS): Wearable wireless assistive device for augmented speech.

    Science.gov (United States)

    Marjanovic, Nicholas; Piccinini, Giacomo; Kerr, Kevin; Esmailbeigi, Hananeh

    2017-07-01

    Speech is an important aspect of human communication; individuals with speech impairment are unable to communicate vocally in real time. Our team has developed the TongueToSpeech (TTS) device with the goal of augmenting speech communication for the vocally impaired. The proposed device is a wearable wireless assistive device that incorporates a capacitive touch keyboard interface embedded inside a discrete retainer. This device connects to a computer, tablet or a smartphone via Bluetooth connection. The developed TTS application converts text typed by the tongue into audible speech. Our studies have concluded that an 8-contact point configuration between the tongue and the TTS device would yield the best user precision and speed performance. On average using the TTS device inside the oral cavity takes 2.5 times longer than the pointer finger using a T9 (Text on 9 keys) keyboard configuration to type the same phrase. In conclusion, we have developed a discrete noninvasive wearable device that allows the vocally impaired individuals to communicate in real time.

  13. Comprehensive model for predicting perceptual image quality of smart mobile devices.

    Science.gov (United States)

    Gong, Rui; Xu, Haisong; Luo, M R; Li, Haifeng

    2015-01-01

    An image quality model for smart mobile devices was proposed based on visual assessments of several image quality attributes. A series of psychophysical experiments were carried out on two kinds of smart mobile devices, i.e., smart phones and tablet computers, in which naturalness, colorfulness, brightness, contrast, sharpness, clearness, and overall image quality were visually evaluated under three lighting environments via categorical judgment method for various application types of test images. On the basis of Pearson correlation coefficients and factor analysis, the overall image quality could first be predicted by its two constituent attributes with multiple linear regression functions for different types of images, respectively, and then the mathematical expressions were built to link the constituent image quality attributes with the physical parameters of smart mobile devices and image appearance factors. The procedure and algorithms were applicable to various smart mobile devices, different lighting conditions, and multiple types of images, and performance was verified by the visual data.

  14. A new device-independent dimension witness and its experimental implementation

    Science.gov (United States)

    Cai, Yu; Bancal, Jean-Daniel; Romero, Jacquiline; Scarani, Valerio

    2016-07-01

    A dimension witness is a criterion that sets a lower bound on the dimension needed to reproduce the observed data. Three types of dimension witnesses can be found in the literature: device-dependent ones, in which the bound is obtained assuming some knowledge on the state and the measurements; device-independent prepare-and-measure ones, that can be applied to any system including classical ones; and device-independent Bell-based ones, that certify the minimal dimension of some entangled systems. Here we consider the Collins-Gisin-Linden-Massar-Popescu Bell-type inequality for four outcomes. We show that a sufficiently high violation of this inequality witnesses d≥slant 4 and present a proof-of-principle experimental observation of such a violation. This presents a first experimental violation of the third type of dimension witness beyond qutrits.

  15. Chemically sensitive interfaces on SAW devices

    Energy Technology Data Exchange (ETDEWEB)

    Ricco, A.J.; Martin, S.J. [Sandia National Labs., Albuquerque, NM (United States); Crooks, R.M.; Xu, Chuanjing [Texas A and M Univ., College Station, TX (United States); Allred, R.E. [Adherent Technologies, Inc., Albuquerque, NM (United States)

    1993-11-01

    Using surface acoustic wave (SAW) devices, three approaches to the effective use of chemically sensitive interfaces that are not highly chemically selective have been examined: (1) molecular identification from time-resolved permeation transients; (2) using multifrequency SAW devices to determine the frequency dependence of analyte/film interactions; (3) use of an array of SAW devices bearing diverse chemically sensitive interfaces to produce a distinct response pattern for each analyte. In addition to their well-known sensitivity to mass changes (0.0035 monolayer of N{sub 2} can be measured), SAW devices respond to the mechanical and electronic properties of thin films, enhancing response information content but making a thorough understanding of the perturbation critical. Simultaneous measurement of changes in frequency and attenuation, which can provide the information necessary to determine the type of perturbation, are used as part of the above discrimination schemes.

  16. Use of Mobile Devices to Access Resources Among Health Professions Students: A Systematic Review.

    Science.gov (United States)

    Mi, Misa; Wu, Wendy; Qiu, Maylene; Zhang, Yingting; Wu, Lin; Li, Jie

    2016-01-01

    This systematic review examines types of mobile devices used by health professions students, kinds of resources and tools accessed via mobile devices, and reasons for using the devices to access the resources and tools. The review included 20 studies selected from articles published in English between January 2010 and April 2015, retrieved from PubMed and other sources. Data extracted included participants, study designs, mobile devices used, mobile resources/apps accessed, outcome measures, and advantages of and barriers to using mobile devices. The review indicates significant variability across the studies in terms of research methods, types of mobile programs implemented, resources accessed, and outcomes. There were beneficial effects of using mobile devices to access resources as well as conspicuous challenges or barriers in using mobile devices.

  17. CIRSE Vascular Closure Device Registry

    International Nuclear Information System (INIS)

    Reekers, Jim A.; Müller-Hülsbeck, Stefan; Libicher, Martin; Atar, Eli; Trentmann, Jens; Goffette, Pierre; Borggrefe, Jan; Zeleňák, Kamil; Hooijboer, Pieter; Belli, Anna-Maria

    2011-01-01

    Purpose: Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. Methods: The CIRSE registry of closure devices with an anchor and a plug started in January 2009 and ended in August 2009. A total of 1,107 patients were included in the registry. Results: Deployment success was 97.2%. Deployment failure specified to access type was 8.8% [95% confidence interval (95% CI) 5.0–14.5] for antegrade access and 1.8% (95% CI 1.1–2.9) for retrograde access (P = 0.001). There was no difference in deployment failure related to local PVD at the access site. Calcification was a reason for deployment failure in only 5.9 cm, and two vessel occlusions. Conclusion: The conclusion of this registry of closure devices with an anchor and a plug is that the use of this device in interventional radiology procedures is safe, with a low incidence of serious access site complications. There seems to be no difference in complications between antegrade and retrograde access and other parameters.

  18. Artificial Pancreas Device Systems for the Closed-Loop Control of Type 1 Diabetes: What Systems Are in Development?

    Science.gov (United States)

    Trevitt, Sara; Simpson, Sue; Wood, Annette

    2016-05-01

    Closed-loop artificial pancreas device (APD) systems are externally worn medical devices that are being developed to enable people with type 1 diabetes to regulate their blood glucose levels in a more automated way. The innovative concept of this emerging technology is that hands-free, continuous, glycemic control can be achieved by using digital communication technology and advanced computer algorithms. A horizon scanning review of this field was conducted using online sources of intelligence to identify systems in development. The systems were classified into subtypes according to their level of automation, the hormonal and glycemic control approaches used, and their research setting. Eighteen closed-loop APD systems were identified. All were being tested in clinical trials prior to potential commercialization. Six were being studied in the home setting, 5 in outpatient settings, and 7 in inpatient settings. It is estimated that 2 systems may become commercially available in the EU by the end of 2016, 1 during 2017, and 2 more in 2018. There are around 18 closed-loop APD systems progressing through early stages of clinical development. Only a few of these are currently in phase 3 trials and in settings that replicate real life. © 2015 Diabetes Technology Society.

  19. Reading device of a radiation image contained in a radioluminescent screen and tomography device containing it

    International Nuclear Information System (INIS)

    Allemand, R.; Cuzin, M.; Parot, P.

    1984-01-01

    The present invention is aimed at improving the random access time to a stimulable radioluminescent screen point (and consequently the reading time of the screen image); it is noticeably useful for longitudinal tomography. The reading device contains a source emitting a stimulation radiation beam towards the stimulable radioluminescent screen, a control mean of the stimulation radiation beam and a deflection mean which allows the beam to scan the screen surface. The device is characterized by the use of a very fast acousto-optical type deflection mean [fr

  20. Zinc Alloys for the Fabrication of Semiconductor Devices

    Science.gov (United States)

    Ryu, Yungryel; Lee, Tae S.

    2009-01-01

    ZnBeO and ZnCdSeO alloys have been disclosed as materials for the improvement in performance, function, and capability of semiconductor devices. The alloys can be used alone or in combination to form active photonic layers that can emit over a range of wavelength values. Materials with both larger and smaller band gaps would allow for the fabrication of semiconductor heterostructures that have increased function in the ultraviolet (UV) region of the spectrum. ZnO is a wide band-gap material possessing good radiation-resistance properties. It is desirable to modify the energy band gap of ZnO to smaller values than that for ZnO and to larger values than that for ZnO for use in semiconductor devices. A material with band gap energy larger than that of ZnO would allow for the emission at shorter wavelengths for LED (light emitting diode) and LD (laser diode) devices, while a material with band gap energy smaller than that of ZnO would allow for emission at longer wavelengths for LED and LD devices. The amount of Be in the ZnBeO alloy system can be varied to increase the energy bandgap of ZnO to values larger than that of ZnO. The amount of Cd and Se in the ZnCdSeO alloy system can be varied to decrease the energy band gap of ZnO to values smaller than that of ZnO. Each alloy formed can be undoped or can be p-type doped using selected dopant elements, or can be n-type doped using selected dopant elements. The layers and structures formed with both the ZnBeO and ZnCdSeO semiconductor alloys - including undoped, p-type-doped, and n-type-doped types - can be used for fabricating photonic and electronic semiconductor devices for use in photonic and electronic applications. These devices can be used in LEDs, LDs, FETs (field effect transistors), PN junctions, PIN junctions, Schottky barrier diodes, UV detectors and transmitters, and transistors and transparent transistors. They also can be used in applications for lightemitting display, backlighting for displays, UV and

  1. Failed fuel detection device

    International Nuclear Information System (INIS)

    Doi, Akira.

    1994-01-01

    The device of the present invention concerns a failed fuel detection device for a nuclear reactor, such as an FBR type reactor, using electroconductive coolants. A sampling port is disposed at the upper portion of the fuel assembly so as to cover the assembly, so that coolants in the fuel assembly are sampled to improve a device for detecting fuel failure. That is, when coolants in the fuel assembly are sampled from the sampling port, the flow of electroconductive coolants in an sampling tube is detected by a flowmeter, to control an electromagnetic pump. The flow of electroconductive coolants is stopped against the waterhead pressure and dynamic pressure of the conductive coolants, and a predetermined amount of the coolants is pumped up to the sampling tank. Gas is supplied to the pumped up coolants so that fissile products are transferred from the coolants to a gas phase. Radiation in the gas in a gas recycling system is measured to detect presence of fuel failure. (I.S.)

  2. Reactor water sampling device

    International Nuclear Information System (INIS)

    Sakamaki, Kazuo.

    1992-01-01

    The present invention concerns a reactor water sampling device for sampling reactor water in an in-core monitor (neutron measuring tube) housing in a BWR type reactor. The upper end portion of a drain pipe of the reactor water sampling device is attached detachably to an in-core monitor flange. A push-up rod is inserted in the drain pipe vertically movably. A sampling vessel and a vacuum pump are connected to the lower end of the drain pipe. A vacuum pump is operated to depressurize the inside of the device and move the push-up rod upwardly. Reactor water in the in-core monitor housing flows between the drain pipe and the push-up rod and flows into the sampling vessel. With such a constitution, reactor water in the in-core monitor housing can be sampled rapidly with neither opening the lid of the reactor pressure vessel nor being in contact with air. Accordingly, operator's exposure dose can be reduced. (I.N.)

  3. Liquid metal purification device

    International Nuclear Information System (INIS)

    Sakai, Takao; Shimoyashiki, Shigehiro.

    1992-01-01

    The device of the present invention concerns a liquid metal purification device for removing and purifying impuries in liquid metal sodium used as coolants of an FBR type reactor. A vessel having a group of pipes made of hydrogen permeable metal at the inside thereof is disposed to the inlet pipeline of a cold trap. The group of hydrogen permeable metal pipes is connected to an exhaust pipe and a vacuum pump, so that the inside of the pipes is exhausted. Liquid metal sodium branched from the main pipeline of a coolant system passes through the outer side of the group of the hydrogen permeable metal pipes. In this cae, hydrogen contained as impurities in the liquid metal sodium diffuses and permeates the hydrogen permeation metal pipes and enters into the pipe group and is discharged out of the system by the vacuum pump. This can mitigate the hydrogen removing burden of the cold trap, to extend the device life time. (I.N.)

  4. Metal-Organic Frameworks as Active Materials in Electronic Sensor Devices.

    Science.gov (United States)

    Campbell, Michael G; Dincă, Mircea

    2017-05-12

    In the past decade, advances in electrically conductive metal-organic frameworks (MOFs) and MOF-based electronic devices have created new opportunities for the development of next-generation sensors. Here we review this rapidly-growing field, with a focus on the different types of device configurations that have allowed for the use of MOFs as active components of electronic sensor devices.

  5. An image scanning device using radiating energy

    International Nuclear Information System (INIS)

    Jacob, Daniel.

    1976-01-01

    Said invention relates to an image scanning device using radiating energy. More particularly, it relates to a device for generating a scanning beam of rectangular cross section from a γ or X-ray source. Said invention can be applied to radiographic units of the 'microdose' type used by airline staffs and others for the fast efficient inspection of luggage and parcels in view of detecting hidden things [fr

  6. Abnormality diagnosis device for PWR type reactor

    International Nuclear Information System (INIS)

    Kurosawa, Masahiko.

    1993-01-01

    The device of the present invention rapidly detects a small amount of primary coolants leaked from a heat transfer pipes in a steam generator to estimate the scale of the rupture and forecast the transition of the amount of the leakage. That is, a gamma-ray spectrum and dose rate measuring system having a bypass line capable of decaying short half-time nuclides disposed to each of second main steam pipelines and primary coolant pipelines. Data obtained from the measuring systems are compared, to judge the presence of abnormal symptom due to leakage and further, radioactivity concentration in main steams is calculated based on the dose rate at each of the measuring points. Further, radioactivity concentration of the leakage from the secondary main steam pipelines is calculated by change with passage of time. With such procedures, when primary coolants are leaked to the secondary main steam pipelines, the dose rate of the measured system is changed, thereby enabling to recognize the state at the abnormal point. The transition of abnormalities can be forecast with reference to the dose rate by change with passage of time. Further, state of the abnormal point can be recognized based on the gamma-ray spectrum, which is inherent upon occurrence of fuel rupture. (T.S.)

  7. Wearable Fall Detector using Integrated Sensors and Energy Devices

    OpenAIRE

    Sungmook Jung; Seungki Hong; Jaemin Kim; Sangkyu Lee; Taeghwan Hyeon; Minbaek Lee; Dae-Hyeong Kim

    2015-01-01

    Wearable devices have attracted great attentions as next-generation electronic devices. For the comfortable, portable, and easy-to-use system platform in wearable electronics, a key requirement is to replace conventional bulky and rigid energy devices into thin and deformable ones accompanying the capability of long-term energy supply. Here, we demonstrate a wearable fall detection system composed of a wristband-type deformable triboelectric generator and lithium ion battery in conjunction wi...

  8. Study on storage energy devices: supercapacitors, a green alternative

    OpenAIRE

    Rancaño Fernandez, Ariadna

    2011-01-01

    Nowadays, it is increasingly common to hear about environmental issues. This fact keep us to continually try to improve energy optimization, either through new storage devices that pollute less or improvements in the environmental energy generation systems. Recent new types of devices under study are those called supercapacitors. Supercapacitors are electronic devices able to store charge in form of electrical energy. This energy is stored as an electric field, so supercapacitors are less pol...

  9. High Pressure Soxhlet Type Leachability testing device and leaching test of simulated high-level waste glass at high temperature

    International Nuclear Information System (INIS)

    Senoo, Muneaki; Banba, Tsunetaka; Tashiro, Shingo; Shimooka, Kenji; Araki, Kunio

    1979-11-01

    A High Pressure Soxhlet Type Leachability Testing Device (HIPSOL) was developed to evaluate long-period stability of high-level waste (HLW) solids. For simulated HLW solids, temperature dependency of the leachability was investigated at higher temperatures from 100 0 C to 300 0 C at 80 atm. Leachabilities of cesium and sodium at 295 0 C were 20 and 7 times higher than at 100 0 C, respectively. In the repository, the temperatures around solidified products may be hundred 0 C. It is essential to test them at such elevated temperatures. HIPSOL is also usable for accelerated test to evaluate long-period leaching behavior of HLW products. (author)

  10. Protection device for a thermonuclear device

    International Nuclear Information System (INIS)

    Kawashima, Shuichi.

    1986-01-01

    Purpose: To exactly detect the void coefficients of coolants even under high magnetic fields thereby detect the overheat of a thermonuclear device at an early stage. Constitution: The protecting device of this invention comprises a laser beam generation device, a laser beam detection device and an accident detection device. The laser generation device always generates laser beams, which are permeated through coolants and detected by the laser beam detection device, the optical amount of which is transmitted to the accident detection device. The accident detection device judges the excess or insufficiency of the detected optical amount with respect to the optical amount of the laser beams under the stationary state as a reference and issues an accident signal. Since only the optical cables that do not undergo the effect of the magnetic fields are exposed to high magnetic fields in the protection device of this invention, a high reliability can be maintained. (Kamimura, M.)

  11. Cerebrovascular accidents in patients with a ventricular assist device.

    Science.gov (United States)

    Tsukui, Hiroyuki; Abla, Adib; Teuteberg, Jeffrey J; McNamara, Dennis M; Mathier, Michael A; Cadaret, Linda M; Kormos, Robert L

    2007-07-01

    A cerebrovascular accident is a devastating adverse event in a patient with a ventricular assist device. The goal was to clarify the risk factors for cerebrovascular accident. Prospectively collected data, including medical history, ventricular assist device type, white blood cell count, thrombelastogram, and infection, were reviewed retrospectively in 124 patients. Thirty-one patients (25%) had 48 cerebrovascular accidents. The mean ventricular assist device support period was 228 and 89 days in patients with and without cerebrovascular accidents, respectively (P cerebrovascular accidents occurred within 4 months after implantation. Actuarial freedom from cerebrovascular accident at 6 months was 75%, 64%, 63%, and 33% with the HeartMate device (Thoratec Corp, Pleasanton, Calif), Thoratec biventricular ventricular assist device (Thoratec Corp), Thoratec left ventricular assist device (Thoratec), and Novacor device (WorldHeart, Oakland, Calif), respectively. Twenty cerebrovascular accidents (42%) occurred in patients with infections. The mean white blood cell count at the cerebrovascular accident was greater than the normal range in patients with infection (12,900/mm3) and without infection (9500/mm3). The mean maximum amplitude of the thrombelastogram in the presence of infection (63.6 mm) was higher than that in the absence of infection (60.7 mm) (P = .0309). The risk of cerebrovascular accident increases with a longer ventricular assist device support period. Infection may activate platelet function and predispose the patient to a cerebrovascular accident. An elevation of the white blood cell count may also exacerbate the risk of cerebrovascular accident even in patients without infection. Selection of device type, prevention of infection, and meticulous control of anticoagulation are key to preventing cerebrovascular accident.

  12. Consumer preferences for telemedicine devices and services in South Korea.

    Science.gov (United States)

    Ahn, Joongha; Shin, Jungwoo; Lee, Jongsu; Shin, Kwangsoo; Park, Hayoung

    2014-02-01

    The scope of healthcare has been expanding from caring for sick people to keeping people from becoming sick, and telemedicine will play a significant role in this new healthcare paradigm. This study investigated consumer preferences and willingness to pay for attributes of telemedicine services in South Korea. A market simulation was conducted to examine the market shares of alternative services and their relationships to the perceived usefulness of service types and preferred device types. Using a conjoint survey, we collected data on consumer preferences for six telemedicine service attributes. Data analysis used the Bayesian mixed logit model. The market simulation estimated the probabilities of a specific service alternative being chosen using estimated model coefficients. Wearable devices were the most preferred, followed by smart-home and smartphone devices. Consumers perceived managing blood glucose to be the most useful telemedicine service, followed by monitoring oxygen saturation and blood pressure. The market simulation indicated that consumer preferences for device types were associated with the types of chronic diseases for which management through telemedicine services is perceived to be useful. As the focus of healthcare moves from treating patients to keeping individuals healthy, a key factor for the successful deployment of telemedicine services is understanding consumer perceptions and attitudes. The results of this study revealed the dynamics of consumer preferences with regard to service attributes.

  13. An oxide-based thermoelectric generator: Transversal thermoelectric strip-device

    Science.gov (United States)

    Teichert, S.; Bochmann, A.; Reimann, T.; Schulz, T.; Dreßler, C.; Töpfer, J.

    2015-07-01

    A special design of an oxide-based transversal thermoelectric device utilizing thermoelectric oxides in combination with a ceramic multilayer technology is proposed. Metal strips within the ceramic matrix replace the tilted stack of alternating layers used in artificial anisotropic transversal thermoelectric devices. Numerical three-dimensional simulations of both device types reveal better thermoelectric performance data for the device with metal stripes. A monolithic transversal strip-device based on the material combination La1.97Sr0.03CuO4/Ag6Pd1 was prepared and electrically characterized. A maximum power output of 4.0 mW was determined at ΔT = 225 K for the monolithic device. The observed results are in remarkable agreement with three-dimensional numerical simulations utilizing the transport parameters of the two materials and the geometry data of the device.

  14. Automatic exchange unit for control rod drive device

    International Nuclear Information System (INIS)

    Nasu, Seiji; Sasaki, Masayoshi.

    1982-01-01

    Purpose: To enable automatic reoperation and continuation without external power interruption remedy device at the time of recovering the interrupted power soruce during automatic positioning operation. Constitution: In case of an automatic exchange unit for a control rod drive device of the control type for setting the deviation between the positioning target position and the present position of the device to zero, the position data of the drive device of the positioning target value of the device is automatically read, and an interlock of operation inhibit is applied to a control system until the data reading is completed and automatic operation start or restart conditions are sequentially confirmed. After the confirmation, the interlock is released to start the automatic operation or reoperation. Accordingly, the automatic operation can be safely restarted and continued. (Yoshihara, H.)

  15. Racial/ethnic variation in devices used to access patient portals.

    Science.gov (United States)

    Chang, Eva; Blondon, Katherine; Lyles, Courtney R; Jordan, Luesa; Ralston, James D

    2018-01-01

    We examined racial/ethnic variation in the devices used by patients to access medical records through an online patient portal. Retrospective, cross-sectional analysis. Using data from 318,700 adults enrolled in an integrated delivery system between December 2012 and November 2013, we examined: 1) online patient portal use that directly engages the electronic health record and 2) portal use over desktops/laptops only, mobile devices only, or both device types. The primary covariate was race/ethnicity (non-Hispanic white, black, Hispanic, and Asian). Other covariates included age, sex, primary language, and neighborhood-level income and education. Portal use and devices used were assessed with multiple and multinomial logistic models, respectively. From December 2012 to November 2013, 56% of enrollees used the patient portal. Of these portal users, 62% used desktops/laptops only, 6% used mobile devices only, and 32% used both desktops/laptops and mobile devices. Black, Hispanic, and Asian enrollees had significantly lower odds of portal use than whites. Black and Hispanic portal users also were significantly more likely to use mobile devices only (relative risk ratio, 1.73 and 1.44, respectively) and both device types (1.21 and 1.07, respectively) than desktops/laptops only compared with whites. Although racial/ethnic minority enrollees were less likely to access the online patient portal overall, a greater proportion of black and Hispanic users accessed the patient portal with mobile devices than did non-Hispanic white users. The rapid spread of mobile devices among racial/ethnic minorities may help reduce variation in online patient portal use. Mobile device use may represent an opportunity for healthcare organizations to further engage black and Hispanic enrollees in online patient portal use.

  16. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    OpenAIRE

    A. Yu. Galkin; A. G. Komar; A. A. Grigorenko

    2015-01-01

    In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO...

  17. INTERFACE DEVICE FOR NONDESTRUCTIVE TESTING OF RESIDUAL SURFACE STRESSES

    Directory of Open Access Journals (Sweden)

    Gennady A. Perepelkin

    2016-01-01

    Full Text Available The paper considers the organization of connection of a personal computer with a device for nondestructive testing of residual surface stresses. The device works is based on the phenomenon of diffraction of ionizing radiation from the crystal lattice near the surface of the crystallites. Proposed software interface to the organization for each type of user: the device developers, administrators, users. Some aspects of the organization of communication microcontroller to a PC via USB-port

  18. Obstacles delaying the prompt deployment of piston-type mechanical cardiopulmonary resuscitation devices during emergency department resuscitation: a video-recording and time-motion study.

    Science.gov (United States)

    Huang, Edward Pei-Chuan; Wang, Hui-Chih; Ko, Patrick Chow-In; Chang, Anna Marie; Fu, Chia-Ming; Chen, Jiun-Wei; Liao, Yen-Chen; Liu, Hung-Chieh; Fang, Yao-De; Yang, Chih-Wei; Chiang, Wen-Chu; Ma, Matthew Huei-Ming; Chen, Shyr-Chyr

    2013-09-01

    The quality of cardiopulmonary resuscitation (CPR) is important to survival after cardiac arrest. Mechanical devices (MD) provide constant CPR, but their effectiveness may be affected by deployment timeliness. To identify the timeliness of the overall and of each essential step in the deployment of a piston-type MD during emergency department (ED) resuscitation, and to identify factors associated with delayed MD deployment by video recordings. Between December 2005 and December 2008, video clips from resuscitations with CPR sessions using a MD in the ED were reviewed using time-motion analyses. The overall deployment timeliness and the time spent on each essential step of deployment were measured. There were 37 CPR recordings that used a MD. Deployment of MD took an average 122.6 ± 57.8s. The 3 most time-consuming steps were: (1) setting the device (57.8 ± 38.3s), (2) positioning the patient (33.4 ± 38.0 s), and (3) positioning the device (14.7 ± 9.5s). Total no flow time was 89.1 ± 41.2s (72.7% of total time) and associated with the 3 most time-consuming steps. There was no difference in the total timeliness, no-flow time, and no-flow ratio between different rescuer numbers, time of day of the resuscitation, or body size of patients. Rescuers spent a significant amount of time on MD deployment, leading to long no-flow times. Lack of familiarity with the device and positioning strategy were associated with poor performance. Additional training in device deployment strategies are required to improve the benefits of mechanical CPR. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Treatment of sleep-disordered breathing with positive airway pressure devices: technology update

    Directory of Open Access Journals (Sweden)

    Johnson KG

    2015-10-01

    Full Text Available Karin Gardner Johnson, Douglas Clark Johnson Department of Medicine, Baystate Medical Center, Springfield, MA, USA Abstract: Many types of positive airway pressure (PAP devices are used to treat sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. These include continuous PAP, autoadjusting CPAP, bilevel PAP, adaptive servoventilation, and volume-assured pressure support. Noninvasive PAP has significant leak by design, which these devices adjust for in different manners. Algorithms to provide pressure, detect events, and respond to events vary greatly between the types of devices, and vary among the same category between companies and different models by the same company. Many devices include features designed to improve effectiveness and patient comfort. Data collection systems can track compliance, pressure, leak, and efficacy. Understanding how each device works allows the clinician to better select the best device and settings for a given patient. This paper reviews PAP devices, including their algorithms, settings, and features. Keywords: BiPAP, CPAP, iVAPS, AVAPS, ASV, positive pressure respiration, instrumentation, treatment algorithm

  20. Cognitive streaming on android devices

    NARCIS (Netherlands)

    Torres Vega, M.; Mocanu, D.C.; Barresi, R.; Fortino, G.; Liotta, A.

    2015-01-01

    As the number of mobile devices increases, so do the complexity of wireless networks and the user's requirements. This tendency makes necessary for Multimedia Services to take the needed actions to adapt to the upcoming technology. A prominent example of this type of services is HTTP Adaptive Video

  1. Development of new damping devices for piping

    International Nuclear Information System (INIS)

    Kobayashi, Hiroe

    1991-01-01

    An increase of the damping ratio is known to be very effective for the seismic design of a piping system. Increasing the damping ratio and reducing the seismic response of the piping system, the following three types of damping devices for piping systems are introduced: (1) visco-elastic damper, (2) elasto-plastic damper and (3) compact dynamic damper. The dynamic characteristics of these damping devices were investigated by the component test and the applicability of them to the piping system was confirmed by the vibration test using a three dimensional piping model. These damping devices are more effective than mechanical snubbers to reduce the vibration of the piping system. (author)

  2. An Initial Evaluation of Tablet Devices & What Are the Next Steps?

    Science.gov (United States)

    McKillen, Tracey

    2016-01-01

    This paper describes an evaluation of tablet devices for a Graduate Entry Medical School (GEMS). The purpose of this evaluation is to assess what type of tablet device could meet the needs of a GEMS student. GEMS requirements for the evaluation include; using the tablet device to replace paper teaching resources in lectures and tutorials and…

  3. On the fundamental performance of the floating offshore wave power device (FOWAD)

    International Nuclear Information System (INIS)

    Hotta, H.; Washio, Y.; Miyazaki, T.

    1990-01-01

    This paper reports on the wave power absorption, wave dissipation, mooring line tension and oscillation in regular and irregular (long created and short created) waves of the floating offshore wave power device (FOWAD) that were measured and analyzed by a scale model test in a wave tank. FOWAD is an oscillating water column type device equipped with air turbine generators, and air chambers facing the waves. Therefore, it belongs in the close of terminator type wave power devices. It has several projecting walls in front of each air chamber, several buoyancy compartments behind each chamber and stabilizer at the keel. The measured data indicates that, the performance and stability were improved in comparison with former terminator type devices, FOWAD absorbed about 30% of wave power and mooring line tension was within the limits of safety even in rough seas. Nevertheless the performance for dissipation of waves can be improved. This paper describes on the results of the model test and subsequent analysis

  4. Organic Photovoltaic Devices Based on Oriented n-Type Molecular Films Deposited on Oriented Polythiophene Films.

    Science.gov (United States)

    Mizokuro, Toshiko; Tanigaki, Nobutaka; Miyadera, Tetsuhiko; Shibata, Yousei; Koganezawa, Tomoyuki

    2018-04-01

    The molecular orientation of π-conjugated molecules has been reported to significantly affect the performance of organic photovoltaic devices (OPVs) based on molecular films. Hence, the control of molecular orientation is a key issue toward the improvement of OPV performance. In this research, oriented thin films of an n-type molecule, 3,4,9,10-Perylenetetracarboxylic Bisbenzimida-zole (PTCBI), were formed by deposition on in-plane oriented polythiophene (PT) films. Orientation of the PTCBI films was evaluated by polarized UV-vis spectroscopy and 2D-Grazing incidence X-ray diffraction. Results indicated that PTCBI molecules on PT film exhibit nearly edge-on and in-plane orientation (with molecular long axis along the substrate), whereas PTCBI molecules without PT film exhibit neither. OPVs composed of PTCBI molecular film with and without PT were fabricated and evaluated for correlation of orientation with performance. The OPVs composed of PTCBI film with PT showed higher power conversion efficiency (PCE) than that of film without PT. The experiment indicated that in-plane orientation of PTCBI molecules absorbs incident light more efficiently, leading to increase in PCE.

  5. CIRSE Vascular Closure Device Registry

    Science.gov (United States)

    Müller-Hülsbeck, Stefan; Libicher, Martin; Atar, Eli; Trentmann, Jens; Goffette, Pierre; Borggrefe, Jan; Zeleňák, Kamil; Hooijboer, Pieter; Belli, Anna-Maria

    2010-01-01

    Purpose Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. Methods The CIRSE registry of closure devices with an anchor and a plug started in January 2009 and ended in August 2009. A total of 1,107 patients were included in the registry. Results Deployment success was 97.2%. Deployment failure specified to access type was 8.8% [95% confidence interval (95% CI) 5.0–14.5] for antegrade access and 1.8% (95% CI 1.1–2.9) for retrograde access (P = 0.001). There was no difference in deployment failure related to local PVD at the access site. Calcification was a reason for deployment failure in only 5.9 cm, and two vessel occlusions. Conclusion The conclusion of this registry of closure devices with an anchor and a plug is that the use of this device in interventional radiology procedures is safe, with a low incidence of serious access site complications. There seems to be no difference in complications between antegrade and retrograde access and other parameters. PMID:20981425

  6. Ferroelectric-gate field effect transistor memories device physics and applications

    CERN Document Server

    Ishiwara, Hiroshi; Okuyama, Masanori; Sakai, Shigeki; Yoon, Sung-Min

    2016-01-01

    This book provides comprehensive coverage of the materials characteristics, process technologies, and device operations for memory field-effect transistors employing inorganic or organic ferroelectric thin films. This transistor-type ferroelectric memory has interesting fundamental device physics and potentially large industrial impact. Among the various applications of ferroelectric thin films, the development of nonvolatile ferroelectric random access memory (FeRAM) has progressed most actively since the late 1980s and has achieved modest mass production levels for specific applications since 1995. There are two types of memory cells in ferroelectric nonvolatile memories. One is the capacitor-type FeRAM and the other is the field-effect transistor (FET)-type FeRAM. Although the FET-type FeRAM claims ultimate scalability and nondestructive readout characteristics, the capacitor-type FeRAMs have been the main interest for the major semiconductor memory companies, because the ferroelectric FET has fatal handic...

  7. Amphoteric oxide semiconductors for energy conversion devices: a tutorial review.

    Science.gov (United States)

    Singh, Kalpana; Nowotny, Janusz; Thangadurai, Venkataraman

    2013-03-07

    In this tutorial review, we discuss the defect chemistry of selected amphoteric oxide semiconductors in conjunction with their significant impact on the development of renewable and sustainable solid state energy conversion devices. The effect of electronic defect disorders in semiconductors appears to control the overall performance of several solid-state ionic devices that include oxide ion conducting solid oxide fuel cells (O-SOFCs), proton conducting solid oxide fuel cells (H-SOFCs), batteries, solar cells, and chemical (gas) sensors. Thus, the present study aims to assess the advances made in typical n- and p-type metal oxide semiconductors with respect to their use in ionic devices. The present paper briefly outlines the key challenges in the development of n- and p-type materials for various applications and also tries to present the state-of-the-art of defect disorders in technologically related semiconductors such as TiO(2), and perovskite-like and fluorite-type structure metal oxides.

  8. Medical device software: defining key terms.

    Science.gov (United States)

    Pashkov, Vitalii; Gutorova, Nataliya; Harkusha, Andrii

    one of the areas of significant growth in medical devices has been the role of software - as an integral component of a medical device, as a standalone device and more recently as applications on mobile devices. The risk related to a malfunction of the standalone software used within healthcare is in itself not a criterion for its qualification or not as a medical device. It is therefore, necessary to clarify some criteria for the qualification of stand-alone software as medical devices Materials and methods: Ukrainian, European Union, United States of America legislation, Guidelines developed by European Commission and Food and Drug Administration's, recommendations represented by international voluntary group and scientific works. This article is based on dialectical, comparative, analytic, synthetic and comprehensive research methods. the legal regulation of software which is used for medical purpose in Ukraine limited to one definition. In European Union and United States of America were developed and applying special guidelines that help developers, manufactures and end users to difference software on types standing on medical purpose criteria. Software becomes more and more incorporated into medical devices. Developers and manufacturers may not have initially appreciated potential risks to patients and users such situation could have dangerous results for patients or users. It is necessary to develop and adopt the legislation that will intend to define the criteria for the qualification of medical device software and the application of the classification criteria to such software, provide some illustrative examples and step by step recommendations to qualify software as medical device.

  9. TPA device for demonstration

    International Nuclear Information System (INIS)

    1980-02-01

    The TPA (torus plasma for amature) is a small race-trac type device made by the technical service division to demonstrate basic properties of plasma such as electron temperature, conductivity, effect of helical field for toroidal drift, and shape of plasma in mirror and cusp magnetic field in linear section. The plasmas are produced by RF discharge (-500W) and/or DC discharge (-30 mA) within glass discharge tube. Where major radius is 50 cm, length of linear section is 50 cm, toroidal magnetic field is 200 gauss. The device has been designed to be compact with only 100 V power source (-3.2 KW for the case without helical field) and to be full automatic sequence of operation. (author)

  10. A Multifunctional Envelope-Type Nano Device Containing a pH-Sensitive Cationic Lipid for Efficient Delivery of Short Interfering RNA to Hepatocytes In Vivo.

    Science.gov (United States)

    Sato, Yusuke; Harashima, Hideyoshi; Kohara, Michinori

    2016-01-01

    Various types of nanoparticles have been developed with the intent of efficiently delivering short interfering RNA (siRNA) to hepatocytes to date. To achieve efficient SiRNA delivery, various aspects of the delivery processes and physical properties need to be considered. We recently developed an original lipid nanoparticle, a multifunctional envelope-type nano device (MEND) containing YSK05, a pH-sensitive cationic lipid (YSK05-MEND). The YSK05-MEND with SiRNA in its formulation showed hepatocyte-specific uptake and robust gene silencing in hepatocytes after intravenous administration. Here, we describe the procedure used in the preparation and characterization method of the YSK05-MEND.

  11. Improvements in or relating to charge coupled devices

    International Nuclear Information System (INIS)

    Shannon, J.M.

    1980-01-01

    This invention relates to charge coupled devices for converting an electromagnetic radiation pattern in a certain wavelength range, particularly but not exclusively an infrared radiation pattern, into electrical signals. A semiconductor layer within this device can be of n-type silicon with a deep level impurity concentration present as proton bombardment induced defects in the crystal lattice or as an ion implanted concentration. (UK)

  12. Characterization of current transport in ferroelectric polymer devices

    KAUST Repository

    Hanna, Amir

    2014-01-01

    We report the charge injection characteristics in poly(vinylidene fluoride-trifluoroethylene), P(VDF-TrFE), as a function of electrode material in metal/ferroelectric/metal device structures. Symmetric and asymmetric devices with Al, Ag, Au and Pt electrodes were fabricated to determine the dominant carrier type, injection current density, and to propose transport mechanisms in the ferroelectric polymer. Higher work function metals such as Pt are found to inject less charges compared to lower work function metals, implying n-type conduction behavior for P(VDF-TrFE) with electrons as the dominant injected carrier. Two distinct charge transport regimes were identified in the P(VDF-TrFE) devices; a Schottky-limited conduction regime for low to intermediate fields (E < 20 MV/m), and a space-charge limited conduction (SCLC) regime for high fields (20 < E < 120 MV/m). Implication of these results for degradation in P(VDF-TrFE) memory performance are discussed. © 2013 Elsevier B.V. All rights reserved.

  13. Device-Centric Monitoring for Mobile Device Management

    Directory of Open Access Journals (Sweden)

    Luke Chircop

    2016-03-01

    Full Text Available The ubiquity of computing devices has led to an increased need to ensure not only that the applications deployed on them are correct with respect to their specifications, but also that the devices are used in an appropriate manner, especially in situations where the device is provided by a party other than the actual user. Much work which has been done on runtime verification for mobile devices and operating systems is mostly application-centric, resulting in global, device-centric properties (e.g. the user may not send more than 100 messages per day across all applications being difficult or impossible to verify. In this paper we present a device-centric approach to runtime verify the device behaviour against a device policy with the different applications acting as independent components contributing to the overall behaviour of the device. We also present an implementation for Android devices, and evaluate it on a number of device-centric policies, reporting the empirical results obtained.

  14. Health state utilities associated with attributes of weekly injection devices for treatment of type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Louis S. Matza

    2017-11-01

    Full Text Available Abstract Background Glucagon-like peptide-1 (GLP-1 receptor agonists are often recommended as part of combination therapy for type 2 diabetes when oral medication does not result in sufficient glycemic control. Several GLP-1 receptor agonists are available as weekly injections. These medications vary in their injection delivery systems, and these differences could impact quality of life and treatment preference. The purpose of this study was to estimate utilities associated with attributes of injection delivery systems for weekly GLP-1 therapies. Methods Participants with type 2 diabetes in the UK valued health states in time trade-off interviews. The health states (drafted based on literature, device instructions for use, and clinician interviews had identical descriptions of type 2 diabetes, but differed in description of the treatment process. One health state described oral treatment, while six others described oral treatment plus a weekly injection. The injection health states varied in three aspects of the treatment administration process: requirements for reconstituting the medication (i.e., mixing the medication prior to the injection, waiting during medication preparation, and needle handling. Every participant valued all seven health states. Results A total of 209 participants completed interviews (57.4% male; mean age = 60.4y. The mean utility of the oral treatment health state was 0.89. All injection health states had significantly (p < 0.01 lower utilities ranging from 0.86 to 0.88. Differences among health state utilities suggest that each administration requirement had a small but measureable disutility: -0.004 (reconstitution, -0.004 (needle handling, -0.010 (reconstitution, needle handling, and -0.020 (reconstitution, waiting, needle handling. Conclusions Findings suggest it is feasible to use the TTO method to quantify preferences among injection treatment processes. It may be useful to incorporate these utility differences

  15. Status and Prospects of ZnO-Based Resistive Switching Memory Devices

    Science.gov (United States)

    Simanjuntak, Firman Mangasa; Panda, Debashis; Wei, Kung-Hwa; Tseng, Tseung-Yuen

    2016-08-01

    In the advancement of the semiconductor device technology, ZnO could be a prospective alternative than the other metal oxides for its versatility and huge applications in different aspects. In this review, a thorough overview on ZnO for the application of resistive switching memory (RRAM) devices has been conducted. Various efforts that have been made to investigate and modulate the switching characteristics of ZnO-based switching memory devices are discussed. The use of ZnO layer in different structure, the different types of filament formation, and the different types of switching including complementary switching are reported. By considering the huge interest of transparent devices, this review gives the concrete overview of the present status and prospects of transparent RRAM devices based on ZnO. ZnO-based RRAM can be used for flexible memory devices, which is also covered here. Another challenge in ZnO-based RRAM is that the realization of ultra-thin and low power devices. Nevertheless, ZnO not only offers decent memory properties but also has a unique potential to be used as multifunctional nonvolatile memory devices. The impact of electrode materials, metal doping, stack structures, transparency, and flexibility on resistive switching properties and switching parameters of ZnO-based resistive switching memory devices are briefly compared. This review also covers the different nanostructured-based emerging resistive switching memory devices for low power scalable devices. It may give a valuable insight on developing ZnO-based RRAM and also should encourage researchers to overcome the challenges.

  16. Towards sustainable design for single-use medical devices.

    Science.gov (United States)

    Hanson, Jacob J; Hitchcock, Robert W

    2009-01-01

    Despite their sophistication and value, single-use medical devices have become commodity items in the developed world. Cheap raw materials along with large scale manufacturing and distribution processes have combined to make many medical devices more expensive to resterilize, package and restock than to simply discard. This practice is not sustainable or scalable on a global basis. As the petrochemicals that provide raw materials become more expensive and the global reach of these devices continues into rapidly developing economies, there is a need for device designs that take into account the total life-cycle of these products, minimize the amount of non-renewable materials consumed and consider alternative hybrid reusable / disposable approaches. In this paper, we describe a methodology to perform life cycle and functional analyses to create additional design requirements for medical devices. These types of sustainable approaches can move the medical device industry even closer to the "triple bottom line"--people, planet, profit.

  17. Practice parameters for the use of portable monitoring devices in the investigation of suspected obstructive sleep apnea in adults.

    Science.gov (United States)

    Chesson, Andrew L; Berry, Richard B; Pack, Allan

    2003-11-01

    A variety of devices are used to evaluate patients with a potential diagnosis of obstructive sleep apnea (OSA). A committee comprised of members of the American Academy of Sleep Medicine, American Thoracic Society, and American College of Chest Physicians systematically evaluated data on the use of these devices and developed practice parameters. Three categories of portable monitoring (PM) devices were reviewed with regard to assessing the probability of identifying an apnea-hypopnea index (AHI) of greater or less than 15 in attended and unattended settings. Type 2 (minimum of seven channels, including EEG, EOG, chin EMG, ECG or heart rate, airflow, respiratory effort, oxygen saturation), Type 3 (minimum of four channels, including ventilation or airflow (at least two channels of respiratory movement, or respiratory movement and airflow), heart rate or ECG and oxygen saturation) and Type 4 (most monitors of this type measure a single parameter or two parameters) devices were evaluated, and in-laboratory, attended polysomnography was used as a reference. (1) Insufficient evidence is available to recommend the use of Type 2 PM devices in attended or unattended settings. (2) Type 3 PM devices appear to be capable of being used in an attended setting to increase or to decrease the probability that a patient has an apnea-hypopnea index greater than 15. (3) The use of Type 3 PM devices in an unattended setting is not recommended to rule in, rule out, or both rule in and rule out a diagnosis of OSA. (4) There is some evidence that the use of Type 3 PM devices in an attended in-laboratory setting may be acceptable to both rule in and rule out a diagnosis of OSA if certain limitations are in place. These limitations include manually scoring the records, using the devices only in patients without significant comorbid conditions, having an awareness that symptomatic patients with a negative study should have a Type 1 study, and not using these devices for titrating positive

  18. Firewood processing devices in Finland 2002

    International Nuclear Information System (INIS)

    Mutikainen, A.; Kaerhae, K.

    2002-01-01

    This Forestry Bulletin presents a review of the market situation for firewood processing devices in Finland during March 2002. The review is based on a questionnaire sent to device manufacturers. The firewood processing devices have traditionally been divided into three groups according to their functions: cross-cutting devices, splitting devices and cross-cutting and splitting devices. With a cross-cutting device the tree can be cross-cut only. Because it is easily possible to build the splitting function into a cross-cutting device, merely manufacturing a cross-cutting devices is rare. In all the splitting machines on the market, the splitting is carried out on a horizontally operated hydraulic cylinder pushing against a splitting blade. The types of cross-cutting blade mostly used in cross-cutting and splitting devices are circular i.e. circular saw blade, and chain saw. These devices are called firewood sawing machines. In firewood chopping machines that have a chopping blade, the wood is cross-cut using a spiral or guillotine blade. The splitting is done by a wedge blade or an axe blade. The firewood chopping machines can cross-cut and split stems up to a maximum of 20-22 cm in diameter. Circular blade firewood machines use either a cone screw or hydraulic cylinder and counter blade for splitting. They can handle wood of 20-30 cm thick in diameter. Machines using a chain saw can process stems of a maximum 30-45 cm thick in diameter. All firewood machines that work with a chain saw use a hydraulic cylinder and counter blade for splitting. According to the questionnaire responses, there were 14 (12 Finnish, one Norwegian and one Italian) manufacturers of firewood processing devices in the market. There were over 80 device models. There were only three cross-cutting devices, thirty splitting devices and forty cross-cutting splitting devices. The price range of the devices was 500-66,000 euros (including 22% VAT). According to the MTT Agrifood Research Finland

  19. A chiral-based magnetic memory device without a permanent magnet.

    Science.gov (United States)

    Ben Dor, Oren; Yochelis, Shira; Mathew, Shinto P; Naaman, Ron; Paltiel, Yossi

    2013-01-01

    Several technologies are currently in use for computer memory devices. However, there is a need for a universal memory device that has high density, high speed and low power requirements. To this end, various types of magnetic-based technologies with a permanent magnet have been proposed. Recent charge-transfer studies indicate that chiral molecules act as an efficient spin filter. Here we utilize this effect to achieve a proof of concept for a new type of chiral-based magnetic-based Si-compatible universal memory device without a permanent magnet. More specifically, we use spin-selective charge transfer through a self-assembled monolayer of polyalanine to magnetize a Ni layer. This magnitude of magnetization corresponds to applying an external magnetic field of 0.4 T to the Ni layer. The readout is achieved using low currents. The presented technology has the potential to overcome the limitations of other magnetic-based memory technologies to allow fabricating inexpensive, high-density universal memory-on-chip devices.

  20. Optimal placement of FACTS devices using optimization techniques: A review

    Science.gov (United States)

    Gaur, Dipesh; Mathew, Lini

    2018-03-01

    Modern power system is dealt with overloading problem especially transmission network which works on their maximum limit. Today’s power system network tends to become unstable and prone to collapse due to disturbances. Flexible AC Transmission system (FACTS) provides solution to problems like line overloading, voltage stability, losses, power flow etc. FACTS can play important role in improving static and dynamic performance of power system. FACTS devices need high initial investment. Therefore, FACTS location, type and their rating are vital and should be optimized to place in the network for maximum benefit. In this paper, different optimization methods like Particle Swarm Optimization (PSO), Genetic Algorithm (GA) etc. are discussed and compared for optimal location, type and rating of devices. FACTS devices such as Thyristor Controlled Series Compensator (TCSC), Static Var Compensator (SVC) and Static Synchronous Compensator (STATCOM) are considered here. Mentioned FACTS controllers effects on different IEEE bus network parameters like generation cost, active power loss, voltage stability etc. have been analyzed and compared among the devices.

  1. Predicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis.

    Science.gov (United States)

    Chung, Hyemoon; Jeon, Byunghwan; Chang, Hyuk-Jae; Han, Dongjin; Shim, Hackjoon; Cho, In Jeong; Shim, Chi Young; Hong, Geu-Ru; Kim, Jung-Sun; Jang, Yangsoo; Chung, Namsik

    2015-12-01

    After left atrial appendage (LAA) device closure, peri-device leakage into the LAA persists due to incomplete occlusion. We hypothesized that pre-procedural three-dimensional (3D) geometric analysis of the interatrial septum (IAS) and LAA orifice can predict this leakage. We investigated the predictive parameters of LAA device closure obtained from baseline cardiac computerized tomography (CT) using a novel 3D analysis system. We conducted a retrospective study of 22 patients who underwent LAA device closure. We defined peri-device leakage as the presence of a Doppler signal inside the LAA after device deployment (group 2, n = 5) compared with patients without peri-device leakage (group 1, n = 17). Conventional parameters were measured by cardiac CT. Angles θ and φ were defined between the IAS plane and the line, linking the LAA orifice center and foramen ovale. Group 2 exhibited significantly better left atrial (LA) function than group 1 (p = 0.031). Pre-procedural θ was also larger in this group (41.9° vs. 52.3°, p = 0.019). The LAA cauliflower-type morphology was more common in group 2. Overall, the patients' LA reserve significantly decreased after the procedure (21.7 mm(3) vs. 17.8 mm(3), p = 0.035). However, we observed no significant interval changes in pre- and post-procedural values of θ and φ in either group (all p > 0.05). Angles between the IAS and LAA orifice might be a novel anatomical parameter for predicting peri-device leakage after LAA device closure. In addition, 3D CT analysis of the LA and LAA orifice could be used to identify clinically favorable candidates for LAA device closure.

  2. User and Device Adaptation in Summarizing Sports Videos

    Science.gov (United States)

    Nitta, Naoko; Babaguchi, Noboru

    Video summarization is defined as creating a video summary which includes only important scenes in the original video streams. In order to realize automatic video summarization, the significance of each scene needs to be determined. When targeted especially on broadcast sports videos, a play scene, which corresponds to a play, can be considered as a scene unit. The significance of every play scene can generally be determined based on the importance of the play in the game. Furthermore, the following two issues should be considered: 1) what is important depends on each user's preferences, and 2) the summaries should be tailored for media devices that each user has. Considering the above issues, this paper proposes a unified framework for user and device adaptation in summarizing broadcast sports videos. The proposed framework summarizes sports videos by selecting play scenes based on not only the importance of each play itself but also the users' preferences by using the metadata, which describes the semantic content of videos with keywords, and user profiles, which describe users' preference degrees for the keywords. The selected scenes are then presented in a proper way using various types of media such as video, image, or text according to device profiles which describe the device type. We experimentally verified the effectiveness of user adaptation by examining how the generated summaries are changed by different preference degrees and by comparing our results with/without using user profiles. The validity of device adaptation is also evaluated by conducting questionnaires using PCs and mobile phones as the media devices.

  3. Primary coolant recycling device for FBR type reactor

    International Nuclear Information System (INIS)

    Kanbe, Mitsuru; Tokiwai, Moriyasu

    1998-01-01

    A primary coolants (liquid sodium) recycling device comprises a plurality of recycling pumps. The recycling pumps are operated while using, as a power source, electric power generated by a thermoelectric power generation system by utilizing heat stored in the coolants. The thermoelectric power generation system comprises a thermo-electric conversion module, heat collecting heat pipes as a high temperature side heat conduction means and heat dissipating pipes as a low temperature side heat conduction means. The heat of coolants is transferred to the surface of the high temperature side of each thermo-electric conversion elements of the thermal power generation system by the heat collecting heat pipes. The heat on the low temperature side of each of the thermo-electric conversion elements is removed by the heat dissipating pipes. Accordingly, temperature difference is caused between both surfaces of the thermo-electric conversion elements. Even upon loss of a main power source due to stoppage of electricity, electric power is generated by utilizing heat of coolants, so that the recycling pumps circulate coolants to cool a reactor core continuously. (I.N.)

  4. Surface and interface analysis of photovoltaic devices

    International Nuclear Information System (INIS)

    Kazmerski, L.L.

    1983-01-01

    Interface chemistry can control the performance and operational lifetime of solar cells, especially thin-film, polycrystalline devices. The composition and elemental integrity of device surfaces, internal junctions, layer and defect interfces can be related to and dominate the electroptical characteristics of the materials/ devices. This paper examines the compositional properties of external and internal surfaces in polycrystaline solar cells, utilizing high-resolution, complementary surface analysis techniques. The electronic properties of these same regions are evaluated using microelectrical characterization methods. Cell performance, in turn, is explained in terms of these relation-ships. Specifically, two solar cell types are used as examples: (1) the polycrystalline Si homojunction and (2) the (Cd Zn)S/CuInSe 2 heterojunction. Throughout these investigations of photovoltaic devices, the limitations and strengths of the surface and electrical microanalyses techniques are emphasized and discussed. (Author) [pt

  5. Thermonuclear device

    International Nuclear Information System (INIS)

    Takano, Hirohisa; Nakamoto, Kazunari; Hanai, Satoshi.

    1984-01-01

    Purpose: To provide coils of high mechanical strength for use at the center of a torus type thermonuclear device. Constitution: A plurality of copper plates having cooling holes and bolt holes and insulation paper sheets of the same shape are prepared. The copper plate is different from the insulation paper sheet only in that the position-phase angle of the opening portion is larger by 15 - 30 0 . The copper plates and the insulation paper sheets are alternately stacked by a required number of turns while displacing the angle, and then clamped by bolts to form a mechanically strong coil with no metallurgical joining. Further, since the insulation paper sheets are not present in the radial direction and only one insulation paper sheet is inserted for each turn in the direction of the coil height, the space occupied by the coil can be decreased. According to this invention, the magnetic flux density at the center of the device can be increased as compared with the conventional case to thereby apply a higher voltage on the side of plasmas. (Moriyama, K.)

  6. Use of reconstructed CT images for evaluation of the position of screw-type temporary anchorage devices implanted in the maxillary molar region

    International Nuclear Information System (INIS)

    Hashimoto, Kazuya

    2007-01-01

    Temporary anchorage devices (TAD) have recently been employed for orthodontic treatment. I attempted to find the safest position for placing the screw-type TAD in the maxillary molar region. Using reconstructed CT images, I investigated the buccolingual and mesiodistal lengths of the interalveolar septums between the maxillary first premolar, second premolar, first molar, and the second molar. For the first and second molars, I measured the distance from the alveolar crest to the maxillary sinus. The results indicated that the safest position for placing a screw-type TAD was the interalveolar septum between the maxillary first molar and the second premolar at about a depth of 4-6 mm from the alveolar crest on the buccal side, and at about a depth of 2-6 mm from the alveolar crest on the palatal side. (author)

  7. Rumble devices for road traffic safety

    CSIR Research Space (South Africa)

    Jobson, AJ

    1973-01-01

    Full Text Available on the approaches to hazardous curves or intersections. City and town engineers had little to report on rumble installations but showed a keen interest in their potential usefulness. Each type of rumble device has certain merits and these are discussed...

  8. Semiconductor devices for all-optical regeneration

    DEFF Research Database (Denmark)

    Öhman, Filip; Bischoff, Svend; Tromborg, Bjarne

    2003-01-01

    We review different implementations of semiconductor devices for all-optical regeneration. A general model will be presented for all-optical regeneration in fiber links, taking into consideration the trade-off between non-linearity and noise. Furthermore we discuss a novel regenerator type, based...

  9. Laser characterisation of a 3D single-type column p-type prototype module read out with ATLAS SCT electronics

    International Nuclear Information System (INIS)

    Ehrich, T.; Kuehn, S.; Boscardin, M.; Dalla Betta, G.-F.; Eckert, S.; Jakobs, K.; Maassen, M.; Parzefall, U.; Piemonte, C.; Pozza, A.; Ronchin, S.; Zorzi, N.

    2007-01-01

    In this paper measurements of a 3D single-type column (3D-stc) microstrip silicon device are shown. The 3D-stc sensor has n-type columns in p-type substrate. It has been connected to an ATLAS SCT ABCD3T chip and is readout with ATLAS SCT electronics at 40 MHz. Spatial measurements were done with a laser setup to investigate the expected low field region in 3D devices. An influence of the p-stops on the collected charge has been observed

  10. Laser characterisation of a 3D single-type column p-type prototype module read out with ATLAS SCT electronics

    Energy Technology Data Exchange (ETDEWEB)

    Ehrich, T. [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder Str. 3, 79104 Freiburg (Germany); Kuehn, S. [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder Str. 3, 79104 Freiburg (Germany)], E-mail: susanne.kuehn@physik.uni-freiburg.de; Boscardin, M.; Dalla Betta, G.-F. [ITC-irst Trento, Microsystems Division, via Sommarive, 18 38050 Povo di Trento (Italy); Eckert, S.; Jakobs, K.; Maassen, M.; Parzefall, U. [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder Str. 3, 79104 Freiburg (Germany); Piemonte, C.; Pozza, A.; Ronchin, S.; Zorzi, N. [ITC-irst Trento, Microsystems Division, via Sommarive, 18 38050 Povo di Trento (Italy)

    2007-12-11

    In this paper measurements of a 3D single-type column (3D-stc) microstrip silicon device are shown. The 3D-stc sensor has n-type columns in p-type substrate. It has been connected to an ATLAS SCT ABCD3T chip and is readout with ATLAS SCT electronics at 40 MHz. Spatial measurements were done with a laser setup to investigate the expected low field region in 3D devices. An influence of the p-stops on the collected charge has been observed.

  11. Micromagnetic simulation of exploratory magnetic logic device with missing corner defect

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiaokuo, E-mail: yangxk0123@163.com; Cai, Li; Zhang, Bin; Cui, Huanqing; Zhang, Mingliang

    2015-11-15

    Magnetic film nanostructures are attractive components of nonvolatile magnetoresistive memories and nanomagnet logic circuits. Recently, we studied switching properties (i.e., null logic preserving) of rectangle shape nanomagnet subjected to fabrication imperfections. Specifically, we presented typical missing corner material-related imperfections and adopted an isosceles triangle to model this defect for nanomagnets. Micromagnetic simulation shows that this kind of imperfections modeling method agrees well with previous experimental observations. Using the proposed defect modeling scheme, we investigate in detail the switching characteristics of different defective stand-alone and coupled nanomagnets. The results suggest that the state transition of defective nanomagnet element highly depends on defect type and device’s aspect ratio, and the defect type B{sub d} needs the largest coercive field, while the defect type D requires the largest null field for switching. These findings can provide key technical parameters and guides for nanomagnet logic circuit design. - Highlights: • We have modeled missing corner defect issue for nanomagnet logic device. • The logic state of defective NML element highly depends on defect type and AR. • The NML device with defect type B{sub d} needs the largest coercive field to reverse state. • The defect type D in the NML devices requires the largest null field to switch.

  12. Charge transport mechanism in p-type copper ion containing triazine thiolate metallopolymer thin film devices

    Science.gov (United States)

    K, Deepak; Roy, Amit; Anjaneyulu, P.; Kandaiah, Sakthivel; Pinjare, Sampatrao L.

    2017-10-01

    The charge transport mechanism in copper ions containing 1,3,5-Triazine-2,4,6-trithiolate (CuTCA) based polymer device in sandwich (Ag/CuTCA/Cu) geometry is studied. The current-voltage (I-V) characteristics of the metallopolymer CuTCA device have shown a transition in the charge transport mechanism from Ohmic to Space-charge limited conduction when temperature and voltage are varied. The carriers in CuTCA devices exhibit hopping transport, in which carriers hop from one site to the other. The hole mobility in this polymer device is found to be dependent on electric field E ( μpα√{E } ) and temperature, which suggests that the polymer has inherent disorder. The electric-field coefficient γ and zero-field mobility μ0 are temperature dependent. The values of mobility and activation energies are estimated from temperature (90-140 K) dependent charge transport studies and found to be in the range of 1 × 10-11-8 × 10-12 m2/(V s) and 16.5 meV, respectively. Temperature dependent electric-field coefficient γ is in the order of 17.8 × 10-4 (m/V)1/2, and the value of zero-field mobility μ0 is in the order of 1.2 × 10-11 m2/(V s) at 140 K. A constant phase element (Q) is used to model the device parameters, which are extracted using the Impedance spectroscopy technique. The bandgap of the polymer is estimated to be 2.6 eV from UV-Vis reflectance spectra.

  13. A swivelling transfer device for nuclear reactors

    International Nuclear Information System (INIS)

    Allain, Albert; Mulot, Pierre; Filloleau, Etienne

    1974-01-01

    The invention relates to a swivelling transfer device for fuel-assemblies. According to the invention, the device comprises, within a protective enclosure, a swivelling system comprising two sets of rails rotatable about an axis and so arranged that the lower and thereof penetrates into the extensions of the extremities of ramps dipped into the reactor and into a storage enclosure. This can apply to the transfer of nuclear reactor fuel assemblies, in particular for reactors of the molten sodium fast neutron type [fr

  14. Radioactive gas waste processing device

    International Nuclear Information System (INIS)

    Soma, Koichi.

    1996-01-01

    The present invention concerns a radioactive gas waste processing device which extracts exhaust gases from a turbine condensator in a BWR type reactor and releases them after decaying radioactivity thereof during temporary storage. The turbine condensator is connected with an extracting ejector, a preheater, a recombiner for converting hydrogen gas into steams, an off gas condensator for removing water content, a flow rate control valve, a dehumidifier, a hold up device for removing radiation contaminated materials, a vacuum pump for sucking radiation decayed-off gases, a circulation water tank for final purification and an exhaustion cylinder by way of connection pipelines in this order. An exhaust gas circulation pipeline is disposed to circulate exhaust gases from an exhaust gas exit pipeline of the recycling water tank to an exhaust gas exit pipeline of the exhaust gas condensator, and a pressure control valve is disposed to the exhaust gas circulation pipeline. This enable to perform a system test for the dehumidification device under a test condition approximate to the load of the dehumidification device under actual operation state, and stabilize both of system flow rate and pressure. (T.M.)

  15. Configurable Resistive Switching between Memory and Threshold Characteristics for Protein-Based Devices

    KAUST Repository

    Wang, Hong

    2015-05-01

    The employ of natural biomaterials as the basic building blocks of electronic devices is of growing interest for biocompatible and green electronics. Here, resistive switching (RS) devices based on naturally silk protein with configurable functionality are demonstrated. The RS type of the devices can be effectively and exactly controlled by controlling the compliance current in the set process. Memory RS can be triggered by a higher compliance current, while threshold RS can be triggered by a lower compliance current. Furthermore, two types of memory devices, working in random access and WORM modes, can be achieved with the RS effect. The results suggest that silk protein possesses the potential for sustainable electronics and data storage. In addition, this finding would provide important guidelines for the performance optimization of biomaterials based memory devices and the study of the underlying mechanism behind the RS effect arising from biomaterials. Resistive switching (RS) devices with configurable functionality based on protein are successfully achieved. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Biological samples positioning device for irradiations on a radial channel at the nuclear research reactor

    International Nuclear Information System (INIS)

    Rodriguez Gual, Maritza; Mas Milian, Felix; Deppman, Airton; Pinto Coelho, Paulo Rogerio

    2010-01-01

    For the demand of an experimental device for biological samples positioning system for irradiations on a radial channel at the nuclear research reactor in operation was constructed and started up a device for the place and remove of the biological samples from the irradiation channels without interrupting the operation of the reactor. The economical valuations are effected comparing with another type of device with the same functions. This work formed part of an international project between Cuba and Brazil that undertook the study of the induced damages by various types of ionizing radiation in DNA molecules. Was experimentally tested the proposed solution, which demonstrates the practical validity of the device. As a result of the work, the experimental device for biological samples irradiations are installed and operating in the radial beam hole No3(BH3) for more than five years at the IEA-R1 Brazilian research reactor according to the solicited requirements the device. The designed device increases considerably the type of studies can be conducted in this reactor. Its practical application in research taking place in that facility, in the field of radiobiology and dosimetry, and so on is immediate

  17. Power source device for thermonuclear device

    International Nuclear Information System (INIS)

    Ozaki, Akira.

    1992-01-01

    The present invention provides a small sized and economical power source device for a thermonuclear device. That is, the device comprises a conversion device having a rated power determined by a power required during a plasma current excitation period and a conversion device having a rated power determined by a power required during a plasma current maintaining period, connected in series to each other. Then, for the former conversion device, power is supplied from an electric power generator and, for the latter, power is supplied from a power system. With such a constitution, during the plasma electric current maintaining period for substantially continuous operation, it is possible to conduct bypassing paired operation for the former conversion device while the electric power generator is put under no load. Further, since a short period rated power may be suffice for the former conversion device and the electric power generator having the great rated power required for the plasma electric current excitation period, they can be reduced in the size and made economical. On the other hand, since the power required for the plasma current maintaining period is relatively small, the capacity of the continuous rated conversion device may be small, and the power can be received from the power system. (I.S.)

  18. Magnetic suspension of the rotor of a ventricular assist device of mixed flow type.

    Science.gov (United States)

    Horikawa, Oswaldo; de Andrade, Aron José Pazin; da Silva, Isaías; Bock, Eduardo Guy Perpetuo

    2008-04-01

    This work presents results of preliminary studies concerning application of magnetic bearing in a ventricular assist device (VAD) being developed by Dante Pazzanese Institute of Cardiology-IDPC (São Paulo, Brazil). The VAD-IDPC has a novel architecture that distinguishes from other known VADs. In this, the rotor has a conical geometry with spiral impellers, showing characteristics that are intermediate between a centrifugal VAD and an axial VAD. The effectiveness of this new type of blood pumping principle was showed by tests and by using it in heart surgery for external blood circulation. However, the developed VAD uses a combination of ball bearings and mechanical seals, limiting the life for some 10 h, making impossible its long-term use or its use as an implantable VAD. As a part of development of an implantable VAD, this work aims at the replacement of ball bearings by a magnetic bearing. The most important magnetic bearing principles are studied and the magnetic bearing developed by Escola Politécnica of São Paulo University (EPUSP-MB) is elected because of its very simple architecture. Besides presenting the principle of the EPUSP-MB, this work presents one possible alternative for applying the EPUSP-MB in the IDPC-VAD.

  19. Transcatheter Device Closure of Patent Ductus Arteriosus

    International Nuclear Information System (INIS)

    Sultan, M.; Ullah, M.; Sadiq, N.; Akhtar, K.; Akbar, H.

    2014-01-01

    Objective: To determine the efficacy, safety and immediate complications encountered during percutaneous device closure of patent ductus arteriosus (PDA). Study Design: Case series. Place and Duration of Study: Department of Paediatric Cardiology, AFIC/NIHD, Rawalpindi, from January 2005 to December 2010. Methodology: Consecutive 500 patients who underwent attempted transcatheter PDA device closure were included in the study. Device type position, success of closure and complications were described as frequency percentage. Results: In 491 cases (98.2%), PDA was successfully occluded including 4 cases (0.8%) where devices were dislodged but retrieved and redeployed in Cath laboratory. PDA occluder devices used in 448 cases (91%) while coils (single or multiple) were used in 42 cases (8.5%) and in one case (0.2%) ASD occluder device was used to occlude the PDA. There were 09 (1.8%) unsuccessful cases, 06 (1.2%) were abandoned as ducts were considered unsuitable for device closure, 02 (0.4%) devices dislodged and needed surgical retrieval and one case (0.2%) was abandoned due to faulty equipment. The narrowest PDA diameter ranged from 0.5 - 14 mm with mean of 4.5 +- 2.4 mm. There was a single (0.2%) mortality. Conclusion: Transcatheter occlusion of PDA by coil or occluder device is an effective therapeutic option with high success rate. Complication rate is low in the hands of skilled operators yet paediatric cardiac surgical back-up cover is mandatory. (author)

  20. Novel simple insulin delivery device reduces barriers to insulin therapy in type 2 diabetes: results from a pilot study.

    Science.gov (United States)

    Hermanns, Norbert; Lilly, Leslie C; Mader, Julia K; Aberer, Felix; Ribitsch, Anja; Kojzar, Harald; Warner, Jay; Pieber, Thomas R

    2015-05-01

    The PaQ® insulin delivery system is a simple-to-use patch-on device that provides preset basal rates and bolus insulin on demand. In addition to feasibility of use, safety, and efficacy (reported elsewhere), this study analyzed the impact of PaQ on patient-reported outcomes, including barriers to insulin treatment, diabetes-related distress, and attitudes toward insulin therapy in patients with type 2 diabetes on a stable multiple daily injection (MDI) regimen. This single-center, open-label, single-arm study comprised three 2-week periods: baseline (MDI), transition from MDI to PaQ, and PaQ treatment. Validated questionnaires were administered during the baseline and PaQ treatment periods: Barriers to Insulin Treatment questionnaire (BIT), Insulin Treatment Appraisal Scale (ITAS), and Problem Areas in Diabetes scale (PAID). Eighteen patients (age 59 ± 5 years, diabetes duration 15 ± 7 years, 21% female, HbA1c 7.7 ± 0.7%) completed the questionnaires. There was a strong, significant effect of PaQ use in mean BIT total scores (difference [D] = -5.4 ± 0.7.7, P = .01, effect size [d] = 0.70). Patients perceived less stigmatization by insulin injection (D = -2.2 ± 6.2, P = .18, d = 0.35), increased positive outcome (D = 1.9 ± 6.6, P = .17, d = 0.29), and less fear of injections (1.3 ± 4.8, P = .55, d = 0.28). Mean change in ITAS scores after PaQ device use showed a nonsignificant improvement of 1.71 ± 5.63 but moderate effect size (d = 0.30, P = .14). No increase in PAID scores was seen. The results and moderate to large effects sizes suggest that PaQ device use has beneficial and clinically relevant effects to overcoming barriers to and negative appraisal of insulin treatment, without increasing other diabetes-related distress. © 2015 Diabetes Technology Society.

  1. Accuracy of mechanical torque-limiting devices for dental implants.

    Science.gov (United States)

    L'Homme-Langlois, Emilie; Yilmaz, Burak; Chien, Hua-Hong; McGlumphy, Edwin

    2015-10-01

    A common complication in implant dentistry is unintentional implant screw loosening. The critical factor in the prevention of screw loosening is the delivery of the appropriate target torque value. Mechanical torque-limiting devices (MTLDs) are the most frequently recommended devices by the implant manufacturers to deliver the target torque value to the screw. Two types of MTLDs are available: friction-style and spring-style. Limited information is available regarding the influence of device type on the accuracy of MTLDs. The purpose of this study was to determine and compare the accuracy of spring-style and friction-style MTLDs. Five MTLDs from 6 different dental implant manufacturers (Astra Tech/Dentsply, Zimmer Dental, Biohorizons, Biomet 3i, Straumann [ITI], and Nobel Biocare) (n=5 per manufacturer) were selected to determine their accuracy in delivering target torque values preset by their manufacturers. All torque-limiting devices were new and there were 3 manufacturers for the friction-style and 3 manufacturers for the spring-style. The procedure of target torque measurement was performed 10 times for each device and a digital torque gauge (Chatillon Model DFS2-R-ND; Ametek) was used to record the measurements. Statistical analysis used nonparametric tests to determine the accuracy of the MTLDs in delivering target torque values and Bonferroni post hoc tests were used to assess pairwise comparisons. Median absolute difference between delivered torque values and target torque values of friction-style and spring-style MTLDs were not significantly different (P>.05). Accuracy of Astra Tech and Zimmer Dental friction-style torque-limiting devices were significantly different than Biohorizons torque-limiting devices (Ptorque value. Astra Tech and Zimmer Dental friction-style torque-limiting devices were significantly more accurate than Biohorizons (C) torque-limiting devices (Ptorque-limiting devices fell within ±10% of the target torque value preset by the

  2. The DIRC counter: A new type of particle identification device for B factories

    International Nuclear Information System (INIS)

    Coyle, P.; Lu, A.

    1992-07-01

    A very thin, solid radiator, totally internally reflecting, imaging Cherenkov counter (DIRC) is described. this device is well matched to the hadronic charged particle identification requirements at an asymmetric e + e - B Factory

  3. The DIRC counter: A new type of particle identification device for B factories

    International Nuclear Information System (INIS)

    Ratcliff, B.

    1993-01-01

    A very thin, solid radiator, totally internally reflecting, imaging Cherenkov counter (DIRC) is described. This device is well matched to the hadronic charged particle identification requirements at an asymmetric e + e - B Factory

  4. Toward flexible polymer and paper-based energy storage devices

    Energy Technology Data Exchange (ETDEWEB)

    Nyholm, Leif [Department of Materials Chemistry, The Aangstroem Laboratory, Uppsala University, Box 538, SE-751 21 Uppsala (Sweden); Nystroem, Gustav; Mihranyan, Albert; Stroemme, Maria [Nanotechnology and Functional Materials, Department of Engineering Sciences, The Aangstroem Laboratory, Uppsala University, Box 534, SE-751 21 Uppsala (Sweden)

    2011-09-01

    All-polymer and paper-based energy storage devices have significant inherent advantages in comparison with many currently employed batteries and supercapacitors regarding environmental friendliness, flexibility, cost and versatility. The research within this field is currently undergoing an exciting development as new polymers, composites and paper-based devices are being developed. In this report, we review recent progress concerning the development of flexible energy storage devices based on electronically conducting polymers and cellulose containing composites with particular emphasis on paper-based batteries and supercapacitors. We discuss recent progress in the development of the most commonly used electronically conducting polymers used in flexible device prototypes, the advantages and disadvantages of this type of energy storage devices, as well as the two main approaches used in the manufacturing of paper-based charge storage devices. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Fractional-order devices

    CERN Document Server

    Biswas, Karabi; Caponetto, Riccardo; Mendes Lopes, António; Tenreiro Machado, José António

    2017-01-01

    This book focuses on two specific areas related to fractional order systems – the realization of physical devices characterized by non-integer order impedance, usually called fractional-order elements (FOEs); and the characterization of vegetable tissues via electrical impedance spectroscopy (EIS) – and provides readers with new tools for designing new types of integrated circuits. The majority of the book addresses FOEs. The interest in these topics is related to the need to produce “analogue” electronic devices characterized by non-integer order impedance, and to the characterization of natural phenomena, which are systems with memory or aftereffects and for which the fractional-order calculus tool is the ideal choice for analysis. FOEs represent the building blocks for designing and realizing analogue integrated electronic circuits, which the authors believe hold the potential for a wealth of mass-market applications. The freedom to choose either an integer- or non-integer-order analogue integrator...

  6. Uranium-scintillator device

    International Nuclear Information System (INIS)

    Smith, S.D.

    1979-01-01

    The calorimeter subgroup of the 1977 ISABELLE Summer Workshop strongly recommended investigation of the uranium-scintillator device because of its several attractive features: (1) increased resolution for hadronic energy, (2) fast time response, (3) high density (i.e., 16 cm of calorimeter per interaction length), and, in comparison with uranium--liquid argon detectors, (4) ease of construction, (5) simple electronics, and (6) lower cost. The AFM group at the CERN ISR became interested in such a calorimeter for substantially the same reasons, and in the fall of 1977 carried out tests on a uranium-scintillator (U-Sc) calorimeter with the same uranium plates used in their 1974 studies of the uranium--liquid argon (U-LA) calorimeter. The chief disadvantage of the scintillator test was that the uranium plates were too small to fully contain the hadronic showers. However, since the scintillator and liquid argon tests were made with the plates, direct comparison of the two types of devices could be made

  7. A Systematic Approach for Understanding and Modeling the Performance of Network Security Devices

    OpenAIRE

    Beyene, Yordanos

    2014-01-01

    In this dissertation, we attempt to understand and predict the performance of security devices. More specifically, we examine the following types of questions: (a) Given a security device, and a traffic load, can we predict the performance of the device? (b) Given a traffic load and a security device, how can we tune the performance of the device to achieve the desired trade-off between security and performance? We consider both stateful firewalls and Network Intrusion Prevention systems (NIP...

  8. Elmo bumpy square plasma confinement device

    Science.gov (United States)

    Owen, L.W.

    1985-01-01

    The invention is an Elmo bumpy type plasma confinement device having a polygonal configuration of closed magnet field lines for improved plasma confinement. In the preferred embodiment, the device is of a square configuration which is referred to as an Elmo bumpy square (EBS). The EBS is formed by four linear magnetic mirror sections each comprising a plurality of axisymmetric assemblies connected in series and linked by 90/sup 0/ sections of a high magnetic field toroidal solenoid type field generating coils. These coils provide corner confinement with a minimum of radial dispersion of the confined plasma to minimize the detrimental effects of the toroidal curvature of the magnetic field. Each corner is formed by a plurality of circular or elliptical coils aligned about the corner radius to provide maximum continuity in the closing of the magnetic field lines about the square configuration confining the plasma within a vacuum vessel located within the various coils forming the square configuration confinement geometry.

  9. Molecular and nanoscale materials and devices in electronics.

    Science.gov (United States)

    Fu, Lei; Cao, Lingchao; Liu, Yunqi; Zhu, Daoben

    2004-12-13

    Over the past several years, there have been many significant advances toward the realization of electronic computers integrated on the molecular scale and a much greater understanding of the types of materials that will be useful in molecular devices and their properties. It was demonstrated that individual molecules could serve as incomprehensibly tiny switch and wire one million times smaller than those on conventional silicon microchip. This has resulted very recently in the assembly and demonstration of tiny computer logic circuits built from such molecular scale devices. The purpose of this review is to provide a general introduction to molecular and nanoscale materials and devices in electronics.

  10. Implantable Medical Devices; Networking Security Survey

    Directory of Open Access Journals (Sweden)

    Siamak Aram

    2016-08-01

    Full Text Available The industry of implantable medical devices (IMDs is constantly evolving, which is dictated by the pressing need to comprehensively address new challenges in the healthcare field. Accordingly, IMDs are becoming more and more sophisticated. Not long ago, the range of IMDs’ technical capacities was expanded, making it possible to establish Internet connection in case of necessity and/or emergency situation for the patient. At the same time, while the web connectivity of today’s implantable devices is rather advanced, the issue of equipping the IMDs with sufficiently strong security system remains unresolved. In fact, IMDs have relatively weak security mechanisms which render them vulnerable to cyber-attacks that compromise the quality of IMDs’ functionalities. This study revolves around the security deficiencies inherent to three types of sensor-based medical devices; biosensors, insulin pump systems and implantable cardioverter defibrillators. Manufacturers of these devices should take into consideration that security and effectiveness of the functionality of implants is highly dependent on the design. In this paper, we present a comprehensive study of IMDs’ architecture and specifically investigate their vulnerabilities at networking interface.

  11. Determining the mode of high voltage breakdowns in vacuum devices

    International Nuclear Information System (INIS)

    Miller, H.C.; Furno, E.J.; Sturtz, J.P.

    1980-01-01

    High voltage breakdowns (HVBs) occur in many vacuum devices. It frequently is of great practical interest to know the type (or mode) of such HVB's, since this can indicate weak points in the device. Post-mortems can sometimes be helpful, but it would be quite desirable to have a technique which would allow the HVB mode to be determined in an operating device. Photography can be quite helpful, but unfortunately many devices do not permit optical access to the region of interest. However, the idea of using photography in conjunction with other diagnostic techniques to establish the validity of these techniques seemed promising, since these techniques could then be used to determine the mode of HVBs in opaque devices. A literature search indicates that promising techniques are to measure the voltage applied to the device (or the current through the device) and also to look for x-rays generated by the device during an HVB

  12. A New Method of Viewing Attachment Document of eMail on Various Mobile Devices

    Science.gov (United States)

    Ko, Heeae; Seo, Changwoo; Lim, Yonghwan

    As the computing power of the mobile devices is improving rapidly, many kinds of web services are also available in mobile devices just as Email service. Mobile Mail Service began early, but this service is mostly limited in some specified mobile devices such as Smart Phone. That is a limitation that users have to purchase specified phone to be benefited from Mobile Mail Service. In this paper, it uses DIDL (digital item declaration language) markup type defined in MPEG-21 and MobileGate Server, and solved this problem. DIDL could be converted to other markup types which are displayed by mobile devices. By transforming PC Web Mail contents including attachment document to DIDL markup through MobileGate Server, the Mobile Mail Service could be available for all kinds of mobile devices.

  13. New implantable therapeutic device for the control of an atrial fibrillation attack using the Peltier element.

    Science.gov (United States)

    Yambe, Tomoyuki; Sumiyoshi, Taketada; Koga, Chihiro; Shiraishi, Yasuyuki; Miura, Hidekazu; Sugita, Norihiro; Tanaka, Akira; Yoshizawa, Makoto

    2012-01-01

    For the development of the new therapeutic device for the atrial fibrillation, implantable cooling device using Peltier element was developed in this study. An implantable cooling device had been consisted from Peltier element with transcutaneous energy transmission system (TETS). 1st coil can be contacted from outside of the body, when the patients will feel palpitation. Electrical current will be induced to the implanted 2nd coil. Peltier element will able to cool the surface of the atrium. For the confirmation of the effect of the cooling device, trial manufacture model was developed. Animal experiments using six healthy adult goats after animal ethical committee allowance was carried out. Fourth intercostals space had been opened after anesthesia inhalation, and various sensors had been inserted. AF was induced by the electrical current with battery. As the results, AF had been recovered to the normal sinus rhythm after cooling in all six goats. So, this cooling system for the control of AF showed evident effect in these experiments. Smaller size cooling device has been under development aiming at totally implantable type. Catheter type cooling device for the insertion by the use of fiber-scope type is now under planning for the clinical application. This new type device may be able to become good news for the patients with uncontrollable AF.

  14. Dielectrophoresis of gold nanoparticles conjugated to DNA origami structures

    Directory of Open Access Journals (Sweden)

    Anja Henning-Knechtel

    2016-07-01

    Full Text Available DNA nanostructures are promising construction materials to bridge the gap between self-assembly of functional molecules and conventional top-down fabrication methods in nanotechnology. Their positioning onto specific locations of a microstructured substrate is an important task towards this aim. Here we study manipulation and positioning of pristine and of gold nanoparticle-conjugated tubular DNA origami structures using ac dielectrophoresis. The dielectrophoretic behavior was investigated employing fluorescence microscopy. For the pristine origami, a significant dielectrophoretic response was found to take place in the megahertz range, whereas, due to the higher polarizability of the metallic nanoparticles, the nanoparticle/DNA hybrid structures required a lower electrical field strength and frequency for a comparable trapping at the edges of the electrode structure. The nanoparticle conjugation additionally resulted in a remarkable alteration of the DNA structure arrangement. The growth of linear, chain-like structures in between electrodes at applied frequencies in the megahertz range was observed. The long-range chain formation is caused by a local, gold nanoparticle-induced field concentration along the DNA nanostructures, which in turn, creates dielectrophoretic forces that enable the observed self-alignment of the hybrid structures.

  15. Enhancement of efficiencies for tandem green phosphorescent organic light-emitting devices with a p-type charge generation layer

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Byung Soo; Jeon, Young Pyo; Lee, Dae Uk; Kim, Tae Whan, E-mail: twk@hanayng.ac.kr

    2014-10-15

    The operating voltage of the tandem green phosphorescent organic light-emitting device with a 1,4,5,8,9,11-hexaazatriphenylene-hexacarbonitrile layer was improved by 3% over that of the organic light-emitting device with a molybdenum trioxide layer. The maximum brightness of the tandem green phosphorescent organic light-emitting device at 21.9 V was 26,540 cd/m{sup 2}. The dominant peak of the electroluminescence spectra for the devices was related to the fac-tris(2-phenylpyridine) iridium emission. - Highlights: • Tandem OLEDs with CGL were fabricated to enhance their efficiency. • The operating voltage of the tandem OLED with a HAT-CN layer was improved by 3%. • The efficiency and brightness of the tandem OLED were 13.9 cd/A and 26,540 cd/m{sup 2}. • Efficiency of the OLED with a HAT-CN layer was lower than that with a MoO{sub 3} layer. - Abstract: Tandem green phosphorescent organic light-emitting devices with a 1,4,5,8,9,11-hexaazatriphenylene-hexacarbonitrile or a molybdenum trioxide charge generation layer were fabricated to enhance their efficiency. Current density–voltage curves showed that the operating voltage of the tandem green phosphorescent organic light-emitting device with a 1,4,5,8,9,11-hexaazatriphenylene-hexacarbonitrile layer was improved by 3% over that of the corresponding organic light-emitting device with a molybdenum trioxide layer. The efficiency and the brightness of the tandem green phosphorescent organic light-emitting device were 13.9 cd/A and 26,540 cd/m{sup 2}, respectively. The current efficiency of the tandem green phosphorescent organic light-emitting device with a 1,4,5,8,9,11-hexaazatriphenylene-hexacarbonitrile layer was lower by 1.1 times compared to that of the corresponding organic light-emitting device with molybdenum trioxide layer due to the decreased charge generation and transport in the 1,4,5,8,9,11-hexaazatriphenylene-hexacarbonitrile layer resulting from triplet–triplet exciton annihilation.

  16. Percutaneous Transcatheter PDA Device Closure in Infancy

    International Nuclear Information System (INIS)

    Ullah, M.; Sultan, M.; Akhtar, K.; Sadiq, N.; Akbar, H.

    2014-01-01

    Objective: To evaluate the results and complications associated with transcatheter closure of patent ductus arteriosus (PDA) in infants. Study Design: Quasi-experimental study. Place and Duration of Study: Paediatric Cardiology Department of Armed Forces Institute of Cardiology / National Institute of Heart Diseases (AFIC/NIHD), Rawalpindi, from December 2010 to June 2012. Methodology: Infants undergoing transcatheter device closure of PDA were included. All patients were evaluated by experienced Paediatric Cardiologists with 2-D echocardiography and Doppler before the procedure. Success of closure and complications were recorded. Results: The age of patients varied from 05 - 12 months and 31 (56.4%) were females. Out of the 55 infants, 3 (5.4%) were not offered device closure after aortogram (two large tubular type ducts and one tiny duct, considered unsuitable for device closure); while in 50 (96.1%) patients out of remaining 52, the duct was successfully closed with transcatheter PDA device or coil. In one infant, device deployment resulted in acquired coarctation, necessitating device retrieval by Snare followed by surgical duct interruption and another patient had non-fatal cardiac arrest during device deployment leading to abandonment of procedure and subsequent successful surgical interruption. Local vascular complications occurred in 12 (21.8%) of cases and all were satisfactorily treated. Conclusion: Transcatheter device closure of PDA in infants was an effective procedure in the majority of cases; however, here were considerable number of local access site vascular complications. (author)

  17. Radiation hardening of MOS devices by boron

    International Nuclear Information System (INIS)

    Danchenko, V.

    1975-01-01

    A novel technique is disclosed for radiation hardening of MOS devices and specifically for stabilizing the gate threshold potential at room temperature of a radiation subjected MOS field-effect device of the type having a semiconductor substrate, an insulating layer of oxide on the substrate, and a gate electrode disposed on the insulating layer. In the preferred embodiment, the novel inventive technique contemplates the introduction of boron into the insulating oxide, the boron being introduced within a layer of the oxide of about 100A to 300A thickness immediately adjacent the semiconductor-insulator interface. The concentration of boron in the oxide layer is preferably maintained on the order of 10 atoms/ cm 3 . The novel technique serves to reduce and substantially annihilate radiation induced positive gate charge accumulations, which accumulations, if not eliminated, would cause shifting of the gate threshold potential of a radiation subjected MOS device, and thus render the device unstable and/or inoperative. (auth)

  18. Separation and concentration of water-borne contaminants utilizing insulator-based dielectrophoresis.

    Energy Technology Data Exchange (ETDEWEB)

    Lapizco-Encinas, Blanca Hazalia; Fiechtner, Gregory J.; Cummings, Eric B.; Davalos, Rafael V.; Kanouff, Michael P.; Simmons, Blake Alexander; McGraw, Gregory J.; Salmi, Allen J.; Ceremuga, Joseph T.; Fintschenko, Yolanda

    2006-01-01

    This report focuses on and presents the capabilities of insulator-based dielectrophoresis (iDEP) microdevices for the concentration and removal of water-borne bacteria, spores and inert particles. The dielectrophoretic behavior exhibited by the different particles of interest (both biological and inert) in each of these systems was observed to be a function of both the applied electric field and the characteristics of the particle, such as size, shape, and conductivity. The results obtained illustrate the potential of glass and polymer-based iDEP devices to act as a concentrator for a front-end device with significant homeland security and industrial applications for the threat analysis of bacteria, spores, and viruses. We observed that the polymeric devices exhibit the same iDEP behavior and efficacy in the field of use as their glass counterparts, but with the added benefit of being easily mass fabricated and developed in a variety of multi-scale formats that will allow for the realization of a truly high-throughput device. These results also demonstrate that the operating characteristics of the device can be tailored through the device fabrication technique utilized and the magnitude of the electric field gradient created within the insulating structures. We have developed systems capable of handling numerous flow rates and sample volume requirements, and have produced a deployable system suitable for use in any laboratory, industrial, or clinical setting.

  19. Radiation dose distributions due to sudden ejection of cobalt device

    International Nuclear Information System (INIS)

    Abdelhady, Amr

    2016-01-01

    The evaluation of the radiation dose during accident in a nuclear reactor is of great concern from the viewpoint of safety. One of important accident must be analyzed and may be occurred in open pool type reactor is the rejection of cobalt device. The study is evaluating the dose rate levels resulting from upset withdrawal of co device especially the radiation dose received by the operator in the control room. Study of indirect radiation exposure to the environment due to skyshine effect is also taken into consideration in order to evaluate the radiation dose levels around the reactor during the ejection trip. Microshield, SHLDUTIL, and MCSky codes were used in this study to calculate the radiation dose profiles during cobalt device ejection trip inside and outside the reactor building. - Highlights: • This study aims to calculate the dose rate profiles after cobalt device ejection from open-pool-type reactor core. • MicroShield code was used to evaluate the dose rates inside the reactor control room. • McSKY code was used to evaluate the dose rates outside the reactor building. • The calculated dose rates for workers are higher than the permissible limits after 18 s from device ejection.

  20. Device-Centric Monitoring for Mobile Device Management

    OpenAIRE

    Chircop, Luke; Colombo, Christian; Pace, Gordon J.

    2016-01-01

    The ubiquity of computing devices has led to an increased need to ensure not only that the applications deployed on them are correct with respect to their specifications, but also that the devices are used in an appropriate manner, especially in situations where the device is provided by a party other than the actual user. Much work which has been done on runtime verification for mobile devices and operating systems is mostly application-centric, resulting in global, device-centri...

  1. Rapidly patterning micro/nano devices by directly assembling ions and nanomaterials

    OpenAIRE

    Na Liu; Feifei Wang; Lianqing Liu; Haibo Yu; Shaorong Xie; Jun Wang; Yuechao Wang; Gwo-Bin Lee; Wen J. Li

    2016-01-01

    The synthesis and assembly of components are key steps in micro/nano device manufacturing. In this article, we report an optically controlled assembly method that can rapidly pattern micro/nano devices by directly assembling ions and nanomaterials without expensive physical masks and complex etching processes. Utilizing this controllable process, different types of device components (e.g., metallic and semiconductor) can be fabricated and assembled in 10?30?seconds, which is far more rapid an...

  2. Atomic switch: atom/ion movement controlled devices for beyond von-neumann computers.

    Science.gov (United States)

    Hasegawa, Tsuyoshi; Terabe, Kazuya; Tsuruoka, Tohru; Aono, Masakazu

    2012-01-10

    An atomic switch is a nanoionic device that controls the diffusion of metal ions/atoms and their reduction/oxidation processes in the switching operation to form/annihilate a conductive path. Since metal atoms can provide a highly conductive channel even if their cluster size is in the nanometer scale, atomic switches may enable downscaling to smaller than the 11 nm technology node, which is a great challenge for semiconductor devices. Atomic switches also possess novel characteristics, such as high on/off ratios, very low power consumption and non-volatility. The unique operating mechanisms of these devices have enabled the development of various types of atomic switch, such as gap-type and gapless-type two-terminal atomic switches and three-terminal atomic switches. Novel functions, such as selective volatile/nonvolatile, synaptic, memristive, and photo-assisted operations have been demonstrated. Such atomic switch characteristics can not only improve the performance of present-day electronic systems, but also enable development of new types of electronic systems, such as beyond von- Neumann computers. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. α-sealed transfer device and portable plastic film sealers

    International Nuclear Information System (INIS)

    Fu Zhujun; Shan Ruixia

    1990-04-01

    An α transfer device which can be operated remotely is presented. The device is able to perform sealed transfer of radioactive articles from a hot cell or shielded glove box to the outside and non-radioactive articles from the outside to a hot cell or shielded glove box by using bag sealing technology. The structure of the transfer device is simple. Its operation is safe and reliable. The sealing performance of the device is very good (for alpha). The use of this transfer device will greatly reduce α contamination of the building and creates a favourable condition for operating radioactive materials in an undivided area. The portable heat sealing device is also a necessary tool in bag sealing technology and α-sealed transfer. Two types of portable plastic film sealers have been developed. Their structure is simple. The operation of the portable plastic film sealers is easy. Their performance is also excellent. Both the α-sealed transfer device and portable plastic film sealers are very useful to the reprocessing plant of nuclear fuel

  4. Nuclear reactor types

    International Nuclear Information System (INIS)

    Jones, P.M.S.

    1987-01-01

    The characteristics of different reactor types designed to exploit controlled fission reactions are explained. Reactors vary from low power research devices to high power devices especially designed to produce heat, either for direct use or to produce steam to drive turbines to generate electricity or propel ships. A general outline of basic reactors (thermal and fast) is given and then the different designs considered. The first are gas cooled, including the Magnox reactors (a list of UK Magnox stations and reactor performance is given), advanced gas cooled reactors (a list of UK AGRs is given) and the high temperature reactor. Light water cooled reactors (pressurized water [PWR] and boiling water [BWR] reactors) are considered next. Heavy water reactors are explained and listed. The pressurized heavy water reactors (including CANDU type reactors), boiling light water, steam generating heavy water reactors and gas cooled heavy water reactors all come into this category. Fast reactors (liquid metal fast breeder reactors and gas cooled fast reactors) and then water-cooled graphite-moderated reactors (RBMK) (the type at Chernobyl-4) are discussed. (U.K.)

  5. Flexible and Stretchable Optoelectronic Devices using Silver Nanowires and Graphene.

    Science.gov (United States)

    Lee, Hanleem; Kim, Meeree; Kim, Ikjoon; Lee, Hyoyoung

    2016-06-01

    Many studies have accompanied the emergence of a great interest in flexible or/and stretchable devices for new applications in wearable and futuristic technology, including human-interface devices, robotic skin, and biometric devices, and in optoelectronic devices. Especially, new nanodimensional materials enable flexibility or stretchability to be brought based on their dimensionality. Here, the emerging field of flexible devices is briefly introduced using silver nanowires and graphene, which are famous nanomaterials for the use of transparent conductive electrodes, as examples, and their unique functions originating from the intrinsic property of these nanomaterials are highlighted. It is thought that this work will evoke more interest and idea exchanges in this emerging field and hopefully can trigger a breakthrough on a new type of optoelectronics and optogenetic devices in the near future. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Design and Implementation of Pointer-Type Multi Meters Intelligent Recognition Device Based on ARM Platform

    Science.gov (United States)

    Cui, Yang; Luo, Wang; Fan, Qiang; Peng, Qiwei; Cai, Yiting; Yao, Yiyang; Xu, Changfu

    2018-01-01

    This paper adopts a low power consumption ARM Hisilicon mobile processing platform and OV4689 camera, combined with a new skeleton extraction based on distance transform algorithm and the improved Hough algorithm for multi meters real-time reading. The design and implementation of the device were completed. Experimental results shows that The average error of measurement was 0.005MPa, and the average reading time was 5s. The device had good stability and high accuracy which meets the needs of practical application.

  7. BWR type reactors

    International Nuclear Information System (INIS)

    Yano, Ryoichi; Sato, Takashi; Osaki, Masahiko; Hirayama, Fumio; Watabe, Atsushi.

    1980-01-01

    Purpose: To effectively eliminate radioactive substances released upon loss of coolant accidents in BWR type reactors. Constitution: A high pressure gas jetting device having a plurality of small aperture nozzles is provided above a spray nozzle, that is, at the top of a dry well. The jetting device is connected to a vacuum breaker provided in a pressure suppression chamber. Upon loss of coolant accident, coolants are sprayed from the spray nozzle and air or nitrogen is jetted from the gas jetting device as well. Then, the gases in the dry well are disturbed, whereby radioactive iodine at high concentration liable to be accumulated in the dry well is forced downwardly, dissolved in the spray water and eliminated. (Ikeda, J.)

  8. Influence of ITO patterning on reliability of organic light emitting devices

    International Nuclear Information System (INIS)

    Wang, Zhaokui; Naka, Shigeki; Okada, Hiroyuki

    2009-01-01

    Indium tin oxide (ITO) films are widely used for a transparent electrode of organic light emitting devices (OLEDs) because of its excellent conductivity and transparency. Two types of ITO substrates with different surface roughness were selected to use as anode of OLEDs. In addition, two types of etching process of ITO substrate, particularly the etching time, were also carried out. It was found that the surface roughness and/or the etching process of ITO substrate strongly influenced on an edge of ITO surface, further affected the operating characteristics and reliability of devices.

  9. Automatic control device for the reduction of reactor power

    International Nuclear Information System (INIS)

    Sumida, Susumu; Mizuno, Hiroshi.

    1982-01-01

    Purpose: To early detect troubles in condensate pipeways and feedwater pipeways of BWR-type reactor. Constitution: Detectors are provided to a condensate pipe, a condensator, a low pressure condensate pump, a condensate desalting device and a high pressure condensate pump for constituting condensate pipeways, as well as to a feedwater heater, a feedwater pipe and a feedwater pump for constituting feedwater pipeways. Each of the detectors is connected by way of a lead wire to an abnormal detection and processing device. The abnormal detection and processing device, which are connected to a recycling control device, monitor the input from the detector and sends a control signal to the recycling control system upon calculation of a trouble signal from the detector. (Sekiya, K.)

  10. Auxiliary water supply device for BWR type reactor

    International Nuclear Information System (INIS)

    Sasagawa, Hiroshi.

    1994-01-01

    In the device of the present invention, a cooling condensation means is disposed to a steam discharge channel of a turbine for driving pumps to directly return condensates to the reactor, so that the temperature of the suppression pool water is not elevated. Namely, the cooling condensation means for discharged steams is disposed to the discharge channel of the turbine. The condensate channel from the cooling condensation means is connected to a sucking side of the turbine driving pump. With such a constitution, when the reactor is isolated from a main steam system, reactor scram is conducted. Although the reactor water level is lowered by the reactor scram, the lowering of the reactor water level is prevented by supplementing cooling water by the turbine driving pump using steams generated in the reactor as a power source. The discharged steams after driving the turbine are cooled and condensated by the cooling condensation means by way of the discharge channel and returned to the reactor again by way of the condensate channel. With such procedures, since the temperature of suppression pool water is not elevated, there is no need to operate other cooling systems. In addition, auxiliary water can be supplied for a long period of time. (I.S.)

  11. Coolant make-up device for BWR type reactor

    International Nuclear Information System (INIS)

    Sasagawa, Hiroshi.

    1994-01-01

    In a coolant make-up device, an opening of a pressure equalizing pipeline in a pressure vessel is disposed in coolants above a reactor core and below a usual fluctuation range of a reactor vessel water level. Further, a float check valve is disposed to the pressure equalizing pipeline for preventing coolants in the pressure vessel flowing into the pipeline. If the water level in the pressure vessel is lowered than the setting position for the float check valve, the float drops by its own weight to open the opening of the pressure equalizing pipeline. Then, steams in the pressure vessel are flown into the pipeline, to equalize the pressure between a coolant storage tank and the pressure vessel of the reactor. Coolants in the coolant storage tank is injected to the pressure vessel by way of the water injection pipeline due to the difference of the pressure head between the water level in the coolants storage tank and the water level in the pressure vessel. If the coolants are lowered than the setting position for the float check value, the float check valve does not close unless the water level is recovered to the setting position for the float valve and, accordingly, the coolant make-up is continued. (N.H.)

  12. Monitoring device for the power distribution within a nuclear reactor core

    International Nuclear Information System (INIS)

    Tanzawa, Tomio; Kumanomido, Hironori; Toyoshi, Isamu.

    1986-01-01

    Purpose: To provide a monitoring device for the power distribution in the reactor core that calculates the power distribution based on the measurement by instruments disposed within the reactor core of BWR type reactors. Constitution: The power distribution monitoring device in a reactor core comprises a signal correcting device, a signal normalizing device and a power distribution calculating device, in which the power distribution calculating device is constituted with an average power calculating device for four fuel assemblies and an average power calculating device for fuel assemblies. Gamma-ray signals corrected by the signal correcting device and signals from neutron detectors are inputted to the signal normalizing device, both of which are calibrated to determine the axial gamma-ray signal distribution in the central water gap region with the four fuel assemblies being as the unit. The average power from the four fuel assemblies are inputted to the fuel assembly average power calculating device to allocate to each of the fuel assembly average power thereby attaining the purpose. Further, thermal restriction values are calculated thereby enabling to secure the fuel integrity. (Kamimura, M.)

  13. VibeComm: Radio-Free Wireless Communication for Smart Devices Using Vibration

    Directory of Open Access Journals (Sweden)

    Inhwan Hwang

    2014-11-01

    Full Text Available This paper proposes VibeComm, a novel communication method for smart devices using a built-in vibrator and accelerometer. The proposed approach is ideal for low-rate off-line communication, and its communication medium is an object on which smart devices are placed, such as tables and desks. When more than two smart devices are placed on an object and one device wants to transmit a message to the other devices, the transmitting device generates a sequence of vibrations. The vibrations are propagated through the object on which the devices are placed. The receiving devices analyze their accelerometer readings to decode incoming messages. The proposed method can be the alternative communication method when general types of radio communication methods are not available. VibeComm is implemented on Android smartphones, and a comprehensive set of experiments is conducted to show its feasibility.

  14. Development of a three-microneedle device for hypodermic drug delivery and clinical application.

    Science.gov (United States)

    Fukamizu, Hidekazu; Fujiwara, Masao; Kim, Taishi; Matsushita, Yuki; Tokura, Yoshiki

    2012-08-01

    There is a potential use for intradermic or hypodermic drug delivery in skin surgery or aesthetic surgery. Hypodermic delivery with the use of a noninvasive device can be a more useful, reliable, and effective administration route to obtain higher compliance. The authors developed a microneedle device composed of three fine needles (three-microneedle device). The tip of each needle was fabricated with a bevel angle to release a drug broadly into the tissue in a horizontal fashion. In this study, the authors investigated the usefulness of this newly developed three-microneedle device for hypodermic liquid injection, focusing on the optimum insertion depth and the diffusion of injected materials to the tissue. The authors also assessed the efficacy of and patient satisfaction with three-microneedle device injections of botulinum toxin type A for wrinkle reduction in patients with glabellar rhytides. The three-microneedle device yielded consistent results in hypodermal diffusion. On India ink diffusion test and ultrasonographic imaging, three-microneedle device injection showed a broad diffusion in horizontal extension, as compared with usual 31-gauge needle injection. The efficiency and satisfaction of the patients receiving botulinum toxin type A with the three-microneedle device were highly rated. Three-microneedle device delivery enables accurate and broad diffusion of injected substances, thus reducing the total dose and/or injection number of drugs. Therapeutic, IV.

  15. Self operation type reactor control device

    International Nuclear Information System (INIS)

    Saito, Makoto; Gunji, Minoru.

    1990-01-01

    A boiling-requefication chamber containing transporting materials having somewhat higher boiling point that the usual reactor operation temperature and liquid neutron absorbers having a boiling point sufficiently higher than that of the transporting materials is disposed near the coolant exit of a fuel assembly and connected with a tubular chamber in the reactor core with a moving pipe at the bottom. Since the transporting materials in the boiling-requefication chamber is boiled and expanded by heating, the liquid neutron absorbers are introduced passing through the moving pipe into the cylindrical chamber to control the nuclear reactions. When the temperature is lowered by the control, the transporting materials are liquefied to contract the volume and the liquid neutron absorbers in the cylindrical chamber are returned passing through the moving tube into the boiling-liquefication chamber to make the nuclear reaction vigorous. Thus, self-operation type power conditioning and power stopping are enabled not by way of control rods and not requiring external control, to prevent scram failure or misoperation. (N.H.)

  16. Synthesis and properties of silicon nanowire devices

    Science.gov (United States)

    Byon, Kumhyo

    Silicon nanowire (SiNW) is a very attractive one-dimensional material for future nanoelectronic applications. Reliable control of key field effect transistor (FET) parameters such as conductance, mobility, threshold voltage and on/off ratio is crucial to the applications of SiNW to working logic devices and integrated circuits. In this thesis, we fabricated silicon nanowire field effect transistors (SiNW FETs) and studied the dependence of their electrical transport properties upon various parameters including SiNW growth conditions, post-growth doping, and contact annealing. From these studies, we found how different processes control important FET characteristics. Key accomplishments of this thesis include p-channel enhancement mode FETs, n-channel FETs by post-growth vapor doping and high performance ambipolar devices. In the first part of this work, single crystalline SiNWs were synthesized by thermal evaporation without gold catalysts. FETs were fabricated using both as-grown SiNWs and post-growth n-doped SiNWs. FET from p-type source materials behaves as a p-channel enhancement mode FET which is predominant in logic devices due to its fast operation and low power consumption. Using bismuth vapor, the as-grown SiNWs were doped into n-type materials. The majority carriers in SiNWs can therefore be controlled by proper choice of the vapor phase dopant species. Post-growth doping using vapor phase is applicable to other nanowire systems. In the second part, high performance ambipolar FETs were fabricated. A two step annealing process was used to control the Schottky barrier between SiNW and metal contacts in order to enhance device performance. Initial p-channel SiNW FETs were converted into ambipolar SiNW FETs after contact annealing. Furthermore, significant increases in both on/off ratio and channel mobilities were achieved after contact annealing. Promising device structures to implement ambipolar devices into large scale integrated circuits were proposed

  17. Wearable Performance Devices in Sports Medicine.

    Science.gov (United States)

    Li, Ryan T; Kling, Scott R; Salata, Michael J; Cupp, Sean A; Sheehan, Joseph; Voos, James E

    2016-01-01

    Wearable performance devices and sensors are becoming more readily available to the general population and athletic teams. Advances in technology have allowed individual endurance athletes, sports teams, and physicians to monitor functional movements, workloads, and biometric markers to maximize performance and minimize injury. Movement sensors include pedometers, accelerometers/gyroscopes, and global positioning satellite (GPS) devices. Physiologic sensors include heart rate monitors, sleep monitors, temperature sensors, and integrated sensors. The purpose of this review is to familiarize health care professionals and team physicians with the various available types of wearable sensors, discuss their current utilization, and present future applications in sports medicine. Data were obtained from peer-reviewed literature through a search of the PubMed database. Included studies searched development, outcomes, and validation of wearable performance devices such as GPS, accelerometers, and physiologic monitors in sports. Clinical review. Level 4. Wearable sensors provide a method of monitoring real-time physiologic and movement parameters during training and competitive sports. These parameters can be used to detect position-specific patterns in movement, design more efficient sports-specific training programs for performance optimization, and screen for potential causes of injury. More recent advances in movement sensors have improved accuracy in detecting high-acceleration movements during competitive sports. Wearable devices are valuable instruments for the improvement of sports performance. Evidence for use of these devices in professional sports is still limited. Future developments are needed to establish training protocols using data from wearable devices. © 2015 The Author(s).

  18. Carbon nanotube and graphene device modeling and simulation

    Science.gov (United States)

    Yoon, Young Ki

    The performance of the semiconductors has been improved and the price has gone down for decades. It has been continuously scaled down in size year by year, and now it encounters the fundamental scaling limit. We, therefore, should prepare a new era beyond the conventional semiconductor technologies. One of the most promising devices is possible by carbon nanotube (CNT) or graphene nanoribbon (GNR) in terms of its excellent charge transport properties. Their fundamental material properties and device physics are totally different to those of the conventional devices. In this nano-regime, more sophisticated device modeling and simulation are really needed to elucidate nano-device operation and to save our resources from errors. The numerical simulation works in this dissertation will provide novel view points on the emerging devices. In this dissertation, CNT and GNR devices are numerically studied. The first part of this work is on CNT devices, and a common structure of CNT device has CNT channel, metal source and drain contacts, and gate electrode. We investigate the strain, geometry, and scattering effects on the device performance of CNT field-effect transistors (FETs). It is shown that even a small amount of strain can result in a large effect on the performance of CNTFETs due to the variation of the bandgap and band-structure-limited velocity. A type of strain which produces a larger bandgap results in increased Schottky barrier (SB) height and decreased band-structure-limited velocity, and hence a smaller minimum leakage current, smaller on current, larger maximum achievable Ion/Ioff, and larger intrinsic delay. We also examine geometry effect of partial gate CNTFETs. In the growth process of vertical CNT, underlap between the gate and the bottom electrode is advantageous for transistor operation because it suppresses ambipolar conduction of SBFETs. Both n-type and p-type transistor operations with balanced performance metrics can be achieved on a single

  19. Mobility devices to promote activity and participation

    DEFF Research Database (Denmark)

    Salminen, Anna-Liisa; Brandt, Ase; Samuelsson, Kersti A M

    2009-01-01

    were included if they covered both baseline and follow-up data and focused on activity and participation. Study participants had to be aged over 18 years with mobility limitations. Mobility device interventions encompassed crutches, walking frames, rollators, manual wheelchairs and powered wheelchairs......, and 3 follow-up studies that included before and after data. Two studies dealt with the effects of powered wheelchair interventions and the other studies with various other types of mobility device. Two studies were of high, internal and external methodological quality. Interventions were found......OBJECTIVE: To determine the effectiveness of mobility device interventions in terms of activity and participation for people with mobility limitations. DESIGN: Systematic review. Search of 7 databases during the period 1996 to 2008. METHODS: Controlled studies and non-controlled follow-up studies...

  20. Radiation transmission type pipe wall thinning detection device and measuring instruments utilizing ionizing radiation

    International Nuclear Information System (INIS)

    Higashi, Yasuhiko

    2009-01-01

    We developed the device to detect thinning of pipe thorough heat insulation in Power Plant, etc, even while the plant is under operation. It is necessary to test many parts of many pipes for pipe wall thinning management, but it is difficult within a limited time of the routine test. This device consists of detector and radiation source, which can detect the pipe (less than 500 mm in external diameter, less than 50 mm in thickness) with 1.6%-reproducibility (in a few-minutes measurement), based on the attenuation rate. Operation is easy and effective without removing the heat insulation. We will expand this thinning detection system, and contribute the safety of the Plant. (author)

  1. Non-binary Colour Modulation for Display Device Based on Phase Change Materials

    Science.gov (United States)

    Ji, Hong-Kai; Tong, Hao; Qian, Hang; Hui, Ya-Juan; Liu, Nian; Yan, Peng; Miao, Xiang-Shui

    2016-12-01

    A reflective-type display device based on phase change materials is attractive because of its ultrafast response time and high resolution compared with a conventional display device. This paper proposes and demonstrates a unique display device in which multicolour changing can be achieved on a single device by the selective crystallization of double layer phase change materials. The optical contrast is optimized by the availability of a variety of film thicknesses of two phase change layers. The device exhibits a low sensitivity to the angle of incidence, which is important for display and colour consistency. The non-binary colour rendering on a single device is demonstrated for the first time using optical excitation. The device shows the potential for ultrafast display applications.

  2. Non-binary Colour Modulation for Display Device Based on Phase Change Materials.

    Science.gov (United States)

    Ji, Hong-Kai; Tong, Hao; Qian, Hang; Hui, Ya-Juan; Liu, Nian; Yan, Peng; Miao, Xiang-Shui

    2016-12-19

    A reflective-type display device based on phase change materials is attractive because of its ultrafast response time and high resolution compared with a conventional display device. This paper proposes and demonstrates a unique display device in which multicolour changing can be achieved on a single device by the selective crystallization of double layer phase change materials. The optical contrast is optimized by the availability of a variety of film thicknesses of two phase change layers. The device exhibits a low sensitivity to the angle of incidence, which is important for display and colour consistency. The non-binary colour rendering on a single device is demonstrated for the first time using optical excitation. The device shows the potential for ultrafast display applications.

  3. Off-axis electron holography for the measurement of active dopants in silicon semiconductor devices

    International Nuclear Information System (INIS)

    Cooper, David

    2016-01-01

    There is a need in the semiconductor industry for a dopant profiling technique with nm-scale resolution. Here we demonstrate that off-axis electron holography can be used to provide maps of the electrostatic potential in semiconductor devices with nm-scale resolution. In this paper we will discuss issues regarding the spatial resolution and precision of the technique. Then we will discuss problems with specimen preparation and how this affects the accuracy of the measurements of the potentials. Finally we show results from experimental off-axis electron holography applied to nMOS and pMOS CMOS devices grown on bulk silicon and silicon- on-insulator type devices and present solutions to common problems that are encountered when examining these types of devices. (paper)

  4. Coolant degassing device for PWR type reactors

    International Nuclear Information System (INIS)

    Kita, Kaoru; Takezawa, Kazuaki; Minemoto, Masaki.

    1982-01-01

    Purpose: To efficiently decrease the rare gas concentration in primary coolants, as well as shorten the degassing time required for the periodical inspection in the waste gas processing system of a PWR type reactor. Constitution: Usual degassing method by supplying hydrogen or nitrogen to a volume control tank is replaced with a method of utilizing a degassing tower (method of flowing down processing liquid into the filled tower from above while uprising streams from the bottom of the tower thereby degassing the gases dissolved in the liquid into the steams). The degassing tower is combined with a hydrogen separator or hydrogen recombiner to constitute a waste gas processing system. (Ikeda, J.)

  5. Dose-current discharge correlation analysis in a Mather type Plasma Focus device for medical applications

    Science.gov (United States)

    Sumini, M.; Mostacci, D.; Tartari, A.; Mazza, A.; Cucchi, G.; Isolan, L.; Buontempo, F.; Zironi, I.; Castellani, G.

    2017-11-01

    In a Plasma Focus device the plasma collapses into the pinch where it reaches thermonuclear conditions for a few tens of nanoseconds, becoming a multi-radiation source. The nature of the radiation generated depends on the gas filling the chamber and the device working parameters. The self-collimated electron beam generated in the backward direction with respect to the plasma motion is one of the main radiation sources of interest also for medical applications. The electron beam may be guided against a high Z material target to produce an X-ray beam. This technique offers an ultra-high dose rate source of X-rays, able to deliver during the pinch a massive dose (up to 1 Gy per discharge for the PFMA-3 test device), as measured with EBT3 GafchromicⒸfilm tissue equivalent dosimeters. Given the stochastic behavior of the discharge process, a reliable on-line estimate of the dose-delivered is a very challenging task, in some way preventing a systematic application as a potentially interesting therapy device. This work presents an approach to linking the dose registered by the EBT3 GafchromicⒸfilms with the information contained in the signal recorded during the current discharge process. Processing the signal with the Wigner-Ville distribution, a spectrogram was obtained, displaying the information on intensity at various frequency scales, identifying the band of frequencies representative of the pinch events and define some patterns correlated with the dose.

  6. A Novel Type of Battery-Supercapacitor Hybrid Device with Highly Switchable Dual Performances Based on a Carbon Skeleton/Mg2Ni Free-Standing Hydrogen Storage Electrode.

    Science.gov (United States)

    Li, Na; Du, Yi; Feng, Qing-Ping; Huang, Gui-Wen; Xiao, Hong-Mei; Fu, Shao-Yun

    2017-12-27

    The sharp proliferation of high power electronics and electrical vehicles has promoted growing demands for power sources with both high energy and power densities. Under these circumstances, battery-supercapacitor hybrid devices are attracting considerable attention as they combine the advantages of both batteries and supercapacitors. Here, a novel type of hybrid device based on a carbon skeleton/Mg 2 Ni free-standing electrode without the traditional nickel foam current collector is reported, which has been designed and fabricated through a dispersing-freeze-drying method by employing reduced graphene oxide (rGO) and multiwalled carbon nanotubes (MWCNTs) as a hybrid skeleton. As a result, the Mg 2 Ni alloy is able to deliver a high discharge capacity of 644 mAh g -1 and, more importantly, a high cycling stability with a retention of over 78% after 50 charge/discharge cycles have been achieved, which exceeds almost all the results ever reported on the Mg 2 Ni alloy. Simultaneously, the electrode could also exhibit excellent supercapacitor performances including high specific capacities (296 F g -1 ) and outstanding cycling stability (100% retention after 100 cycles). Moreover, the hybrid device can switch between battery and supercapacitor modes immediately as needed during application. These features make the C skeleton/alloy electrode a highly promising candidate for battery-supercapacitor hybrid devices with high power/energy density and favorable cycling stability.

  7. MetBaro - Pressure Device for Mars MetNet Lander

    Science.gov (United States)

    Haukka, Harri; Polkko, Jouni; Harri, Ari-Matti; Schmidt, Walter; Leinonen, Jussi; Genzer, Maria; Mäkinen, Teemu

    2010-05-01

    MetNet Mars Mission focused for Martian atmospheric science is based on a new semihard landing vehicle called the MetNet Lander (MNL). The MNL will have a versatile science payload focused on the atmospheric science of Mars. The scientific payload of the MetNet Mission encompasses separate instrument packages for the atmospheric entry and descent phase and for the surface operation phase. MetBaro is the pressure sensor of MetNet Lander designed to work on Martian surface. It is based on Barocap® technology developed by Vaisala, Inc. MetBaro is a capacitive type of sensing device where capasitor plates are moved by ambient pressure. MetBaro device consists of two pressure transducers including a total of 4 Barocap® sensor heads of high-stability and high-resolution types. The long-term stability of MetBaro is in order of 20…50 µBar and resolution a few µBar. MetBaro is small, lightweighed and has low power consumption. It weighs about 50g without wires and controlling FPGA, and consumes 15 mW of power. A similar device has successfully flown in Phoenix mission, where it performed months of measurements on Martian ground. Another device is also part of the Mars Science Laboratory REMS instrument (to be launched in 2011).

  8. Development of Magnetorheological Resistive Exercise Device for Rowing Machine

    Directory of Open Access Journals (Sweden)

    Vytautas Grigas

    2016-01-01

    Full Text Available Training equipment used by professional sportsmen has a great impact on their sport performance. Most universal exercisers may help only to improve the general physical condition due to the specific kinematics and peculiar resistance generated by their loading units. Training of effective techniques and learning of psychomotor skills are possible only when exercisers conform to the movements and resistance typical for particular sports kinematically and dynamically. Methodology of developing a magnetorheological resistive exercise device for generating the desired law of passive resistance force and its application in a lever-type rowing machine are described in the paper. The structural parameters of a controllable hydraulic cylinder type device were found by means of the computational fluid dynamics simulation performed by ANSYS CFX software. Parameters describing the magnetorheological fluid as non-Newtonian were determined by combining numerical and experimental research of the resistance force generated by the original magnetorheological damper. A structural scheme of the device control system was developed and the variation of the strength of magnetic field that affects the magnetorheological fluid circulating in the device was determined, ensuring a variation of the resistance force on the oar handle adequate for the resistance that occurs during a real boat rowing stroke.

  9. Device Fabrication and Probing of Discrete Carbon Nanostructures

    KAUST Repository

    Batra, Nitin M

    2015-05-06

    Device fabrication on multi walled carbon nanotubes (MWCNTs) using electrical beam lithography (EBL), electron beam induced deposition (EBID), ion beam induced deposition (IBID) methods was carried out, followed by device electrical characterization using a conventional probe station. A four-probe configuration was utilized to measure accurately the electrical resistivity of MWCNTs with similar results obtained from devices fabricated by different methods. In order to reduce the contact resistance of the beam deposited platinum electrodes, single step vacuum thermal annealing was performed. Microscopy and spectroscopy were carried out on the beam deposited electrodes to follow the structural and chemical changes occurring during the vacuum thermal annealing. For the first time, a core-shell type structure was identified on EBID Pt and IBID Pt annealed electrodes and analogous free standing nanorods previously exposed to high temperature. We believe this observation has important implications for transport properties studies of carbon materials. Apart from that, contamination of carbon nanostructure, originating from the device fabrication methods, was also studied. Finally, based on the observations of faster processing time together with higher yield and flexibility for device preparation, we investigated EBID to fabricate devices for other discrete carbon nanostructures.

  10. Laser micromachining of biofactory-on-a-chip devices

    Science.gov (United States)

    Burt, Julian P.; Goater, Andrew D.; Hayden, Christopher J.; Tame, John A.

    2002-06-01

    Excimer laser micromachining provides a flexible means for the manufacture and rapid prototyping of miniaturized systems such as Biofactory-on-a-Chip devices. Biofactories are miniaturized diagnostic devices capable of characterizing, manipulating, separating and sorting suspension of particles such as biological cells. Such systems operate by exploiting the electrical properties of microparticles and controlling particle movement in AC non- uniform stationary and moving electric fields. Applications of Biofactory devices are diverse and include, among others, the healthcare, pharmaceutical, chemical processing, environmental monitoring and food diagnostic markets. To achieve such characterization and separation, Biofactory devices employ laboratory-on-a-chip type components such as complex multilayer microelectrode arrays, microfluidic channels, manifold systems and on-chip detection systems. Here we discuss the manufacturing requirements of Biofactory devices and describe the use of different excimer laser micromachined methods both in stand-alone processes and also in conjunction with conventional fabrication processes such as photolithography and thermal molding. Particular attention is given to the production of large area multilayer microelectrode arrays and the manufacture of complex cross-section microfluidic channel systems for use in simple distribution and device interfacing.

  11. Facile fabrication of wire-type indium gallium zinc oxide thin-film transistors applicable to ultrasensitive flexible sensors.

    Science.gov (United States)

    Kim, Yeong-Gyu; Tak, Young Jun; Kim, Hee Jun; Kim, Won-Gi; Yoo, Hyukjoon; Kim, Hyun Jae

    2018-04-03

    We fabricated wire-type indium gallium zinc oxide (IGZO) thin-film transistors (TFTs) using a self-formed cracked template based on a lift-off process. The electrical characteristics of wire-type IGZO TFTs could be controlled by changing the width and density of IGZO wires through varying the coating conditions of template solution or multi-stacking additional layers. The fabricated wire-type devices were applied to sensors after functionalizing the surface. The wire-type pH sensor showed a sensitivity of 45.4 mV/pH, and this value was an improved sensitivity compared with that of the film-type device (27.6 mV/pH). Similarly, when the wire-type device was used as a glucose sensor, it showed more variation in electrical characteristics than the film-type device. The improved sensing properties resulted from the large surface area of the wire-type device compared with that of the film-type device. In addition, we fabricated wire-type IGZO TFTs on flexible substrates and confirmed that such structures were very resistant to mechanical stresses at a bending radius of 10 mm.

  12. Use of mobile devices for medical imaging.

    Science.gov (United States)

    Hirschorn, David S; Choudhri, Asim F; Shih, George; Kim, Woojin

    2014-12-01

    Mobile devices have fundamentally changed personal computing, with many people forgoing the desktop and even laptop computer altogether in favor of a smaller, lighter, and cheaper device with a touch screen. Doctors and patients are beginning to expect medical images to be available on these devices for consultative viewing, if not actual diagnosis. However, this raises serious concerns with regard to the ability of existing mobile devices and networks to quickly and securely move these images. Medical images often come in large sets, which can bog down a network if not conveyed in an intelligent manner, and downloaded data on a mobile device are highly vulnerable to a breach of patient confidentiality should that device become lost or stolen. Some degree of regulation is needed to ensure that the software used to view these images allows all relevant medical information to be visible and manipulated in a clinically acceptable manner. There also needs to be a quality control mechanism to ensure that a device's display accurately conveys the image content without loss of contrast detail. Furthermore, not all mobile displays are appropriate for all types of images. The smaller displays of smart phones, for example, are not well suited for viewing entire chest radiographs, no matter how small and numerous the pixels of the display may be. All of these factors should be taken into account when deciding where, when, and how to use mobile devices for the display of medical images. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Electromagnetic compatibility of WLAN adapters with life-supporting medical devices.

    Science.gov (United States)

    Calcagnini, G; Mattei, E; Censi, F; Triventi, M; Lo Sterzo, R; Marchetta, E; Bartolini, P

    2011-05-01

    This paper investigates the electromagnetic compatibility of 45 critical care medical devices (infusion pumps, defibrillators, monitors, lung ventilators, anesthesia machines and external pacemakers) with various types of wireless local area network (WLAN, IEEE 802.11 b/g, 2.45 GHz, 100 mW) adapters. Interference is evaluated by performing ad-hoc tests according to the ANSI C63.18 recommended practice. The behavior of the devices during the tests was monitored using patient simulators/device testers specific for each device class. Electromagnetic interference cases were observed in three of 45 devices at a maximum distance of 5 cm. In two cases the interference caused malfunctions that may have clinical consequences for the patient. The authors' findings show that the use of these wireless local area network adapters can be considered reasonably safe, although interference may occur if they are operated at very close distance (<10 cm) to the medical devices.

  14. Polycaprolactone Thin-Film Micro- and Nanoporous Cell-Encapsulation Devices.

    Science.gov (United States)

    Nyitray, Crystal E; Chang, Ryan; Faleo, Gaetano; Lance, Kevin D; Bernards, Daniel A; Tang, Qizhi; Desai, Tejal A

    2015-06-23

    Cell-encapsulating devices can play an important role in advancing the types of tissue available for transplantation and further improving transplant success rates. To have an effective device, encapsulated cells must remain viable, respond to external stimulus, and be protected from immune responses, and the device itself must elicit a minimal foreign body response. To address these challenges, we developed a micro- and a nanoporous thin-film cell encapsulation device from polycaprolactone (PCL), a material previously used in FDA-approved biomedical devices. The thin-film device construct allows long-term bioluminescent transfer imaging, which can be used for monitoring cell viability and device tracking. The ability to tune the microporous and nanoporous membrane allows selective protection from immune cell invasion and cytokine-mediated cell death in vitro, all while maintaining typical cell function, as demonstrated by encapsulated cells' insulin production in response to glucose stimulation. To demonstrate the ability to track, visualize, and monitor the viability of cells encapsulated in implanted thin-film devices, we encapsulated and implanted luciferase-positive MIN6 cells in allogeneic mouse models for up to 90 days. Lack of foreign body response in combination with rapid neovascularization around the device shows promise in using this technology for cell encapsulation. These devices can help elucidate the metrics required for cell encapsulation success and direct future immune-isolation therapies.

  15. From bioseparation to artificial micro-organs: microfluidic chip based particle manipulation techniques

    Science.gov (United States)

    Stelzle, Martin

    2010-02-01

    Microfluidic device technology provides unique physical phenomena which are not available in the macroscopic world. These may be exploited towards a diverse array of applications in biotechnology and biomedicine ranging from bioseparation of particulate samples to the assembly of cells into structures that resemble the smallest functional unit of an organ. In this paper a general overview of chip-based particle manipulation and separation is given. In the state of the art electric, magnetic, optical and gravitational field effects are utilized. Also, mechanical obstacles often in combination with force fields and laminar flow are employed to achieve separation of particles or molecules. In addition, three applications based on dielectrophoretic forces for particle manipulation in microfluidic systems are discussed in more detail. Firstly, a virus assay is demonstrated. There, antibody-loaded microbeads are used to bind virus particles from a sample and subsequently are accumulated to form a pico-liter sized aggregate located at a predefined position in the chip thus enabling highly sensitive fluorescence detection. Secondly, subcellular fractionation of mitochondria from cell homogenate yields pure samples as was demonstrated by Western Blot and 2D PAGE analysis. Robust long-term operation with complex cell homogenate samples while avoiding electrode fouling is achieved by a set of dedicated technical means. Finally, a chip intended for the dielectrophoretic assembly of hepatocytes and endothelial cells into a structure resembling a liver sinusoid is presented. Such "artificial micro organs" are envisioned as substance screening test systems providing significantly higher predictability with respect to the in vivo response towards a substance under test.

  16. Device for investigation of magnetic flux jumps in ribbon superconductors

    International Nuclear Information System (INIS)

    Andrianov, A.V.; Bashkirov, Yu.A.; Kremlev, M.G.

    1986-01-01

    A device for simulation of magnetic flux jumps in superconductors of conducting magnet sandwich-type windings super-applyed of a ribbon conductor is described. A superconducting magnet with a measuring cassetter are the main elements of the device. An external magnetic field is generated by a two-sectional superconducting magnet permitting to simulate the shape of the magnetic field characteristic for sandwich-type windings. Maximum radial component of the magnetic field is 2 T. Jumps of the magnetic flux are recorded by induction transducers and the magnetic field-by Hall trasducer. The effect of coating of standard metal on magnetic flux jumps in Nb 3 Sn base superconducting ribbon is considered

  17. Current state of low energy EB devices and its application technology

    International Nuclear Information System (INIS)

    Kinoshita, Shinobu

    2000-01-01

    This paper introduced the current state of low energy type EB (electron beam) devices with an acceleration voltage of 300 kV or below and specific application examples. As for EB devices, it introduced the ultra-compact new EB device (microbeam LV), experimental devices, and the pilot/production devices which have been recently developed by the manufacturer to which the author belongs. As the applications of low energy EB devices, it specifically introduced curing, graft polymerization, crosslinking, and sterilization/disinfection with soft electrons: (1) examples of EB curing; antistatic agents in antibacterial/antifungal property imparting processing, hard coat, printing and topcoat, high gloss/pattern transfer processing, and metal vapor deposition film, (2) example of graft polymerization; barrier imparting films, and (3) examples of crosslinking; shrinking films/tubes and foamed sheets. (A.O.)

  18. Dual functions of a new n-type conjugated dendrimer: light-emitting material and additive for polymer electroluminescent devices

    International Nuclear Information System (INIS)

    Park, Jong Hyeok; Kim, Chulhee; Kim, Young Chul

    2009-01-01

    We demonstrate a novel light-emitting diode (LED) of a graded bilayer structure that comprises poly(N-vinylcarbazole) (PVK) with good hole transport ability as the energy donor and a new distyrylanthracene-triazine-based dendrimer with enhanced electron transport ability as the light-emitting molecule. The device contains a graded bilayer structure of the PVK film covered with the dendrimer film prepared by sequential spin-casting of the dendrimer layer from a solvent that only swells the PVK layer. The bilayer device demonstrated a significantly enhanced electoluminescence quantum efficiency compared with the dendrimer single layer device or the PVK : dendrimer blend device with optimized composition. We also prepared composite LEDs with an MEH-PPV : emissive dendrimer blend. By doping the electron-deficient MEH-PPV layer with a small amount of the distyrylanthracene-triazine-based dendrimer, we could not only enhance the device performance but also depress the long-wavelength emission of MEH-PPV.

  19. Dual functions of a new n-type conjugated dendrimer: light-emitting material and additive for polymer electroluminescent devices

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Hyeok [Department of Chemical Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Kim, Chulhee [Hyperstructured Organic Materials Research Center, Department of Polymer Science and Engineering, Inha University, Incheon 402-751 (Korea, Republic of); Kim, Young Chul, E-mail: kimyc@khu.ac.k [Department of Chemical Engineering and RIC-CAMID, Kyung Hee University, Yongin-si, Kyunggi-do 499-701 (Korea, Republic of)

    2009-02-07

    We demonstrate a novel light-emitting diode (LED) of a graded bilayer structure that comprises poly(N-vinylcarbazole) (PVK) with good hole transport ability as the energy donor and a new distyrylanthracene-triazine-based dendrimer with enhanced electron transport ability as the light-emitting molecule. The device contains a graded bilayer structure of the PVK film covered with the dendrimer film prepared by sequential spin-casting of the dendrimer layer from a solvent that only swells the PVK layer. The bilayer device demonstrated a significantly enhanced electoluminescence quantum efficiency compared with the dendrimer single layer device or the PVK : dendrimer blend device with optimized composition. We also prepared composite LEDs with an MEH-PPV : emissive dendrimer blend. By doping the electron-deficient MEH-PPV layer with a small amount of the distyrylanthracene-triazine-based dendrimer, we could not only enhance the device performance but also depress the long-wavelength emission of MEH-PPV.

  20. Dual functions of a new n-type conjugated dendrimer: light-emitting material and additive for polymer electroluminescent devices

    Science.gov (United States)

    Hyeok Park, Jong; Kim, Chulhee; Kim, Young Chul

    2009-02-01

    We demonstrate a novel light-emitting diode (LED) of a graded bilayer structure that comprises poly(N-vinylcarbazole) (PVK) with good hole transport ability as the energy donor and a new distyrylanthracene-triazine-based dendrimer with enhanced electron transport ability as the light-emitting molecule. The device contains a graded bilayer structure of the PVK film covered with the dendrimer film prepared by sequential spin-casting of the dendrimer layer from a solvent that only swells the PVK layer. The bilayer device demonstrated a significantly enhanced electoluminescence quantum efficiency compared with the dendrimer single layer device or the PVK : dendrimer blend device with optimized composition. We also prepared composite LEDs with an MEH-PPV : emissive dendrimer blend. By doping the electron-deficient MEH-PPV layer with a small amount of the distyrylanthracene-triazine-based dendrimer, we could not only enhance the device performance but also depress the long-wavelength emission of MEH-PPV.

  1. Electrothermally-Actuated Micromirrors with Bimorph Actuators—Bending-Type and Torsion-Type

    Directory of Open Access Journals (Sweden)

    Cheng-Hua Tsai

    2015-06-01

    Full Text Available Three different electrothermally-actuated MEMS micromirrors with Cr/Au-Si bimorph actuators are proposed. The devices are fabricated with the SOIMUMPs process developed by MEMSCAP, Inc. (Durham, NC, USA. A silicon-on-insulator MEMS process has been employed for the fabrication of these micromirrors. Electrothermal actuation has achieved a large angular movement in the micromirrors. Application of an external electric current 0.04 A to the bending-type, restricted-torsion-type, and free-torsion-type mirrors achieved rotation angles of 1.69°, 3.28°, and 3.64°, respectively.

  2. Burnable gas concentration control device

    International Nuclear Information System (INIS)

    Goto, Hiroshi; Sanada, Takahiro; Kuboniwa, Takao.

    1980-01-01

    Purpose: To provide connecting ports by doubling nitrogen gas injection pipes thereby to secure lengthiness of the device only by providing one nitrogen gas generator. Constitution: Nitrogen gas injection pipes are provided in two lines separately, and attachable and detachable connecting ports for feeding nitrogen gas connectable to a movable type nitrogen gas supply installation for the purpose of backing up the nitrogen gas generator. (Yoshihara, H.)

  3. Construction and characterization of a plasma focus device and diagnostic test ion

    International Nuclear Information System (INIS)

    Morales Arango, Diana Marsela

    2013-01-01

    In this work we designed and built a Plasma Focus device 2kJ power in order to extend the energy range of devices designed in DPTN CCHEN and study the scaling laws type Plasma Focus Device. The operating parameters of this device are: T/ 4 =907ns, C = 8000nF, L = 42nH, E = 2kJ, lo = 276kA. In such a way to optimize the device tests were performed with various electrode configurations, insulator length, to determine the conditions under which it operates in Plasma Focus mode. Subsequent to the construction tests were performed on devices PF-400J (T /4 = 300ns, C = 880nF, L = 38nH, E = 400J, lo = 168kA) y PF-2kJ (device between the hundreds of joules and kilojoules of energy) diagnostic charged particle emission used the Faraday Cup consisting of a biased graphite collector. For a series of shots on the PF-400J and PF-2kJ operated at 27kV and 20kV respectively kinetic energy distribution of proton between 60keV-150keV were found, deuterons between 60KeV-300KeV. With the idea of optimizing the results in future diagnostic type spectrometer Thompson, spectroscopy and diffraction networks in gas mixture will be implemented

  4. Modern devices the simple physics of sophisticated technology

    CERN Document Server

    Joseph, Charles L

    2016-01-01

    This book discusses the principles of physics through applications of state-of-the-art technologies and advanced instruments. The authors use diagrams, sketches, and graphs coupled with equations and mathematical analysis to enhance the reader's understanding of modern devices. Readers will learn to identify common underlying physical principles that govern several types of devices, while gaining an understanding of the performance trade-off imposed by the physical limitations of various processing methods. The topics discussed in the book assume readers have taken an introductory physics course, college algebra, and have a basic understanding of calculus. * Describes the basic physics behind a large number of devices encountered in everyday life, from the air conditioner to Blu-ray discs * Covers state-of-the-art devices such as spectrographs, photoelectric image sensors, spacecraft systems, astronomical and planetary observatories, biomedical imaging instruments, particle accelerators, and jet engines * Inc...

  5. Extracting forensic evidence from biometric devices

    Science.gov (United States)

    Geradts, Zeno J.; Ruifrok, Arnout C.

    2003-08-01

    Over the past few years, both large multinationals and governments have begun to contribute to even larger projects on biometric devices. Terrorist attacks in America and in other countries have highlighted the need for better identification systems for people as well as improved systems for controlling access to buildings. Another reason for investment in Research and Development in Biometric Devices, is the massive growth in internet-based systems -- whether for e-commerce, e-government or internal processes within organizations. The interface between the system and the user is routinely abused, as people have to remember many complex passwords and handle tokens of various types. In this paper an overview is given of the information that is important to know before an examination of such is systems can be done in a forensic proper way. In forensic evidence with biometric devices the forensic examiner should consider the possibilities of tampering with the biometric systems or the possibilities of unauthorized access before drawing conclusions.

  6. Microfluidic Devices for Studying Biomolecular Interactions

    Science.gov (United States)

    Wilson, Wilbur W.; Garcia, Carlos d.; Henry, Charles S.

    2006-01-01

    Microfluidic devices for monitoring biomolecular interactions have been invented. These devices are basically highly miniaturized liquid-chromatography columns. They are intended to be prototypes of miniature analytical devices of the laboratory on a chip type that could be fabricated rapidly and inexpensively and that, because of their small sizes, would yield analytical results from very small amounts of expensive analytes (typically, proteins). Other advantages to be gained by this scaling down of liquid-chromatography columns may include increases in resolution and speed, decreases in the consumption of reagents, and the possibility of performing multiple simultaneous and highly integrated analyses by use of multiple devices of this type, each possibly containing multiple parallel analytical microchannels. The principle of operation is the same as that of a macroscopic liquid-chromatography column: The column is a channel packed with particles, upon which are immobilized molecules of the protein of interest (or one of the proteins of interest if there are more than one). Starting at a known time, a solution or suspension containing molecules of the protein or other substance of interest is pumped into the channel at its inlet. The liquid emerging from the outlet of the channel is monitored to detect the molecules of the dissolved or suspended substance(s). The time that it takes these molecules to flow from the inlet to the outlet is a measure of the degree of interaction between the immobilized and the dissolved or suspended molecules. Depending on the precise natures of the molecules, this measure can be used for diverse purposes: examples include screening for solution conditions that favor crystallization of proteins, screening for interactions between drugs and proteins, and determining the functions of biomolecules.

  7. Motion control, motion sickness, and the postural dynamics of mobile devices.

    Science.gov (United States)

    Stoffregen, Thomas A; Chen, Yi-Chou; Koslucher, Frank C

    2014-04-01

    Drivers are less likely than passengers to experience motion sickness, an effect that is important for any theoretical account of motion sickness etiology. We asked whether different types of control would affect the incidence of motion sickness, and whether any such effects would be related to participants' control of their own bodies. Participants played a video game on a tablet computer. In the Touch condition, the device was stationary and participants controlled the game exclusively through fingertip inputs via the device's touch screen. In the Tilt condition, participants held the device in their hands and moved the device to control some game functions. Results revealed that the incidence of motion sickness was greater in the Touch condition than in the Tilt condition. During game play, movement of the head and torso differed as a function of the type of game control. Before the onset of subjective symptoms of motion sickness, movement of the head and torso differed between participants who later reported motion sickness and those that did not. We discuss implications of these results for theories of motion sickness etiology.

  8. Mobile Devices in the Classroom: Learning Motivations Predict Specific Types of Multicommunicating Behaviors

    Science.gov (United States)

    Stephens, Keri K.; Pantoja, Gabriel E.

    2016-01-01

    This study provides a first look into how learning motivations are associated with different ways that students use mobile devices to carry on multiple conversations--multicommunicate--while in class. We use self-determination theory to make predictions linking intrinsic motivation, extrinsic motivation, and amotivation, to classroom mobile device…

  9. Study of radiation shielding requirements for n-MOS devices on the Exosat spacecraft. Final report

    International Nuclear Information System (INIS)

    1977-01-01

    The device-degradation and radiation-shielding problems presented by the probable use of an n-channel microprocessor integrated circuit of the 8080 type on the Exosat spacecraft of the European Space Agency, was studied. The radiation exposure likely for this device was calculated, using various assumptions for the amount of surrounding absorber, some being intentional shielding others being normal structure elements and device encapsulation. The conclusion was that this type of device could be used if careful engineering design and quality control were used. Mission doses vary between 5000 and 800 rads for various configurations and some patterns of MOS device will tolerate these doses. The use of specially thickened module covers was not recommended, a better method being upgrading device quality and applying internal (local) shielding when necessary and possibly modular addition of external plates in specific directions only. The result of this shielding philosophy would be much greater efficiency in weight use. The further development of a rads (reduction) per gram philosophy was strongly recommended. Throughout, the strong link between mission success and the choice (and control) of the correct MOS manufacturing technology is emphasized and some guidelines on control of manufactured MOS parts (n-channel and complementary type) with respect to tolerance to radiation are given

  10. Solution-processed, molecular photovoltaics that exploit hole transfer from non-fullerene, n-type materials

    KAUST Repository

    Douglas, Jessica D.; Chen, Mark S.; Niskala, Jeremy R.; Lee, Olivia P.; Yiu, Alan T.; Young, Eric P.; Frechet, Jean

    2014-01-01

    Solution-processed organic photovoltaic devices containing p-type and non-fullerene n-type small molecules obtain power conversion efficiencies as high as 2.4%. The optoelectronic properties of the n-type material BT(TTI-n12)2 allow these devices

  11. In-situ TEM characterization of nanomaterials and devices

    KAUST Repository

    Kim, Moon; Park, Seongyong; Cha, Dong Kyu; Kim, Jiyoung; Floresca, Herman Carlo; Lu, Ning; Wang, Jinguo

    2011-01-01

    Electrical properties of nano size devices were directly measured by TEM. Real time observation of phase transition behavior in PRAM revealed that the volume of the crystalline phase is the main factor in determining cell resistance. In the transistor device, we have identified the doping type and area by measuring the I-V curve at the individual nano contact on the specimen. The evolution of the graphene edge structure was controlled and monitored at and up to 1200°C in-situ. © 2011 IEEE.

  12. In-situ TEM characterization of nanomaterials and devices

    KAUST Repository

    Kim, Moon

    2011-10-01

    Electrical properties of nano size devices were directly measured by TEM. Real time observation of phase transition behavior in PRAM revealed that the volume of the crystalline phase is the main factor in determining cell resistance. In the transistor device, we have identified the doping type and area by measuring the I-V curve at the individual nano contact on the specimen. The evolution of the graphene edge structure was controlled and monitored at and up to 1200°C in-situ. © 2011 IEEE.

  13. Colour Reproduction on Tablet Devices

    Directory of Open Access Journals (Sweden)

    Vladimir Zorić

    2014-07-01

    Full Text Available With the advent of Internet and mobile devices client services and other print production are migrating more and more to online platforms. In a recent technology changeover it is obvious that there is growing number of printers as well need from the customers for the print service providers to expand their business to online and mobile platforms. With this technological transition there are some open questions regarding the possibilities of using the tablet devices for colour soft proofing and other colour related operations. As a display devices on a hardware level there are large similarities with the desktop display devices but the operating systems which are driving them are not yet colour smart. There have been some initial attempts to characterize the colour reproduction on this type of devices and find a possibility of using them not just for information content but also for colour managed content. In this study we have tested several tablets (Apple iPad2,Asus Transformer TF101, Samsung Galaxy Tab 1 with different display and OS technology and tested a software which is intended for colour managed viewing of the reproduction. We have measured the colour reproduction of the tablets with the digital version of the GretagMacbeth ColorChecker card and have calculated the colour differences between the colour chart data and the displayed data. We have calibrated the Ipad2 with the only existing colour management tool the Spyder Gallery and we have also tested the chart display with and without the colour correction of the software. We have found that there are differences in the colour reproduction of the display technologies and that the possibilities of a real colour managed workflow has yet to be resolved on the OS level of tablet and mobile devices

  14. Product Design – From Molecules to Formulations to Devices

    DEFF Research Database (Denmark)

    Gani, Rafiqul; Ng, Ka M.

    2014-01-01

    Product design is a multidisciplinary and diverse subject. This article focuses on product conceptualization (what-to-make) and briefly reviews the corresponding manufacturing processes (how-to-make). Four product types are considered – molecular products, formulated products, devices...... and functional products. For molecular products, computer-aided design tools are used to predict the physicochemical properties of single molecules and blends. For formulated products, an integrated experiment-molecular modelling approach to generate the formula with the specified product attributes is followed....... For devices and functional products, conceptual product design is carried out by modelling the product based on thermodynamics, kinetics and transport processes, by performing experiments, and by decision making based on experience. The results are product specifications in terms of the type of ingredients...

  15. Product design - Molecules, devices, functional products, and formulated products

    DEFF Research Database (Denmark)

    Gani, Rafiqul; Ng, Ka M.

    2015-01-01

    Chemical product design is a multidisciplinary and diverse subject. This article provides an overview of product design while focusing on product conceptualization. Four product types are considered - molecular products, formulated products, devices and functional products. For molecular products......, computer-aided design tools are used to predict the physicochemical properties of single molecules and blends. For formulated products, an integrated experiment-modeling approach is used to generate the formula with the specified product attributes. For devices and functional products, conceptual product...... design is carried out by modeling the product based on thermodynamics, kinetics and transport processes, by performing experiments, and by decision making based on rule-based methods The results are product specifications in terms of the type of ingredients, composition, and the structure, form, shape...

  16. Single-Image Distance Measurement by a Smart Mobile Device.

    Science.gov (United States)

    Chen, Shangwen; Fang, Xianyong; Shen, Jianbing; Wang, Linbo; Shao, Ling

    2017-12-01

    Existing distance measurement methods either require multiple images and special photographing poses or only measure the height with a special view configuration. We propose a novel image-based method that can measure various types of distance from single image captured by a smart mobile device. The embedded accelerometer is used to determine the view orientation of the device. Consequently, pixels can be back-projected to the ground, thanks to the efficient calibration method using two known distances. Then the distance in pixel is transformed to a real distance in centimeter with a linear model parameterized by the magnification ratio. Various types of distance specified in the image can be computed accordingly. Experimental results demonstrate the effectiveness of the proposed method.

  17. Microfluidic Devices in Advanced Caenorhabditis elegans Research

    Directory of Open Access Journals (Sweden)

    Muniesh Muthaiyan Shanmugam

    2016-08-01

    Full Text Available The study of model organisms is very important in view of their potential for application to human therapeutic uses. One such model organism is the nematode worm, Caenorhabditis elegans. As a nematode, C. elegans have ~65% similarity with human disease genes and, therefore, studies on C. elegans can be translated to human, as well as, C. elegans can be used in the study of different types of parasitic worms that infect other living organisms. In the past decade, many efforts have been undertaken to establish interdisciplinary research collaborations between biologists, physicists and engineers in order to develop microfluidic devices to study the biology of C. elegans. Microfluidic devices with the power to manipulate and detect bio-samples, regents or biomolecules in micro-scale environments can well fulfill the requirement to handle worms under proper laboratory conditions, thereby significantly increasing research productivity and knowledge. The recent development of different kinds of microfluidic devices with ultra-high throughput platforms has enabled researchers to carry out worm population studies. Microfluidic devices primarily comprises of chambers, channels and valves, wherein worms can be cultured, immobilized, imaged, etc. Microfluidic devices have been adapted to study various worm behaviors, including that deepen our understanding of neuromuscular connectivity and functions. This review will provide a clear account of the vital involvement of microfluidic devices in worm biology.

  18. Transform Modern Language Learning through Mobile Devices

    Science.gov (United States)

    Tuttle, Harry Grover

    2013-01-01

    College professors can transform their modern language classes through mobile devices. Their students' learning becomes more active, more personalized, more contextual, and more culturally authentic as illustrated through the author's modern language mobile learning classroom examples. In addition, their students engage in many diverse types of…

  19. Clothing, equipment and devices for personnel protection: Its selection according to occupational risks

    International Nuclear Information System (INIS)

    1989-01-01

    This Venezuelan standard establishes the selection of the type of clothing, equipment and devices for personnel protection, to be used by workers according to the occupational risk they deal with, in order to avoid or to reduce the factors that can, directly or indirectly, affect their physical integrity. For the risks not contemplated in this norm, the selection of the type of clothing, equipment and devices for personnel protection, must be done following the corresponding international standard [es

  20. Polymer ferroelectric field-effect memory device with SnO channel layer exhibits record hole mobility

    KAUST Repository

    Caraveo-Frescas, Jesus Alfonso; Khan, M. A.; Alshareef, Husam N.

    2014-01-01

    Here we report for the first time a hybrid p-channel polymer ferroelectric field-effect transistor memory device with record mobility. The memory device, fabricated at 200C on both plastic polyimide and glass substrates, uses ferroelectric polymer P(VDF-TrFE) as the gate dielectric and transparent p-type oxide (SnO) as the active channel layer. A record mobility of 3.3 cm 2V-1s-1, large memory window (~16 V), low read voltages (~-1 V), and excellent retention characteristics up to 5000 sec have been achieved. The mobility achieved in our devices is over 10 times higher than previously reported polymer ferroelectric field-effect transistor memory with p-type channel. This demonstration opens the door for the development of non-volatile memory devices based on dual channel for emerging transparent and flexible electronic devices.

  1. Polymer ferroelectric field-effect memory device with SnO channel layer exhibits record hole mobility

    KAUST Repository

    Caraveo-Frescas, Jesus Alfonso

    2014-06-10

    Here we report for the first time a hybrid p-channel polymer ferroelectric field-effect transistor memory device with record mobility. The memory device, fabricated at 200C on both plastic polyimide and glass substrates, uses ferroelectric polymer P(VDF-TrFE) as the gate dielectric and transparent p-type oxide (SnO) as the active channel layer. A record mobility of 3.3 cm 2V-1s-1, large memory window (~16 V), low read voltages (~-1 V), and excellent retention characteristics up to 5000 sec have been achieved. The mobility achieved in our devices is over 10 times higher than previously reported polymer ferroelectric field-effect transistor memory with p-type channel. This demonstration opens the door for the development of non-volatile memory devices based on dual channel for emerging transparent and flexible electronic devices.

  2. Ontology-Based Device Descriptions and Device Repository for Building Automation Devices

    Directory of Open Access Journals (Sweden)

    Dibowski Henrik

    2011-01-01

    Full Text Available Device descriptions play an important role in the design and commissioning of modern building automation systems and help reducing the design time and costs. However, all established device descriptions are specialized for certain purposes and suffer from several weaknesses. This hinders a further design automation, which is strongly needed for the more and more complex building automation systems. To overcome these problems, this paper presents novel Ontology-based Device Descriptions (ODDs along with a layered ontology architecture, a specific ontology view approach with virtual properties, a generic access interface, a triple store-based database backend, and a generic search mask GUI with underlying query generation algorithm. It enables a formal, unified, and extensible specification of building automation devices, ensures their comparability, and facilitates a computer-enabled retrieval, selection, and interoperability evaluation, which is essential for an automated design. The scalability of the approach to several ten thousand devices is demonstrated.

  3. Frequency-Modulated Wave Dielectrophoresis of Vesicles And Cells: Periodic U-Turns at the Crossover Frequency

    Science.gov (United States)

    Frusawa, Hiroshi

    2018-06-01

    We have formulated the dielectrophoretic force exerted on micro/nanoparticles upon the application of frequency-modulated (FM) electric fields. By adjusting the frequency range of an FM wave to cover the crossover frequency f X in the real part of the Clausius-Mossotti factor, our theory predicts the reversal of the dielectrophoretic force each time the instantaneous frequency periodically traverses f X . In fact, we observed periodic U-turns of vesicles, leukemia cells, and red blood cells that undergo FM wave dielectrophoresis (FM-DEP). It is also suggested by our theory that the video tracking of the U-turns due to FM-DEP is available for the agile and accurate measurement of f X . The FM-DEP method requires a short duration, less than 30 s, while applying the FM wave to observe several U-turns, and the agility in measuring f X is of much use for not only salty cell suspensions but also nanoparticles because the electric-field-induced solvent flow is suppressed as much as possible. The accuracy of f X has been verified using two types of experiment. First, we measured the attractive force exerted on a single vesicle experiencing alternating-current dielectrophoresis (AC-DEP) at various frequencies of sinusoidal electric fields. The frequency dependence of the dielectrophoretic force yields f X as a characteristic frequency at which the force vanishes. Comparing the AC-DEP result of f X with that obtained from the FM-DEP method, both results of f X were found to coincide with each other. Second, we investigated the conductivity dependencies of f X for three kinds of cell by changing the surrounding electrolytes. From the experimental results, we evaluated simultaneously both of the cytoplasmic conductivities and the membrane capacitances using an elaborate theory on the single-shell model of biological cells. While the cytoplasmic conductivities, similar for these cells, were slightly lower than the range of previous reports, the membrane capacitances obtained

  4. Roof slab cooling device in a FBR type reactor

    International Nuclear Information System (INIS)

    Tarutani, Kohei

    1987-01-01

    Purpose: To obtain a roof slab cooling device capable of retaining cooling performance even in a case of electric power supply stop or failure and effective from economical point of view. Constitution: Atmospheric air is introduced into the cooling chamber of a proof slab and spontaneously passed to a exit pipeway connected to a stack thereby cooling the roof slab. Specifically, atmospheric air entered from the inlet pipeway is introduced to the cooling chamber and absorbs heat generate from the inside of the reactor container. Warmed air is sucked from the exit pipeway and then released into the atmosphere passing through the stack. The air cools the roof slab during circulation due to spontaneous passage and keeps the slab at a low temperature. Since the air is passed spontaneously, no power such as for a blower is required at all and, if the electric power supply should be lost, the cooling power can be maintained as it is to provide a high reliability. Further, since no electric power is required for the blowing power, it has high economical merit. (Horiuchi, T.)

  5. Synthesis of Carbon–Metal Multi-Strand Nanocomposites by Discharges in Heptane Between Two Metallic Electrodes

    KAUST Repository

    Hamdan, Ahmad

    2017-04-26

    We studied composite wires assembled from electric field-driven nanoparticles in a dielectric liquid (heptane) to elucidate the exact processes and controlling factors involved in the synthesis of the multi-phase nanocomposites. Filamentary wires are synthesized by a two-step process: (1) abundant nanoparticle production, mostly of carbonaceous types, from heptane decomposition by spark discharge and of metal nanoparticles by electrode erosion and (2) assembly of hydrogenated amorphous carbonaceous nano-clusters with incorporated metal nanoparticles forming wires by dielectrophoretic transport while maintaining a high electric field between electrodes kept sufficiently separated to avoid breakdown. Four types of nanocomposites products are identified to form at different steps in distinctive zones of the setup. The black carbonaceous agglomerates with metal spherules made by electrode erosion represent the pyrolytic residues of heptane decomposition by spark discharge during step 1. The filamentary wires grown in the interelectrode gap during step 2 get assembled by dielectrophoretic transport and chaining forces. Their great stability is shown to express the concurrent effect of polymerization favoured by the abundance of metal catalysts. The nature, abundance, and transformation of solid particles from the source materials versus discharge conditions control the morphological and compositional diversity of the wires. The production of mineral and metal nano-particles traces the efficiency of dielectrophoresis to separate compound particle mixtures by size and to co-synthesize nanostructured microcrystals and nanocomposites. The link between impurities and the variability from nano- to micro-scales of the synthesized products provides an innovative contribution to the knowledge of nanocomposite synthesis triggered by electric field.

  6. Multi-Device to Multi-Device (MD2MD Content-Centric Networking Based on Multi-RAT Device

    Directory of Open Access Journals (Sweden)

    Cheolhoon Kim

    2017-11-01

    Full Text Available This paper proposes a method whereby a device can transmit and receive information using a beacon, and also describes application scenarios for the proposed method. In a multi-device to multi-device (MD2MD content-centric networking (CCN environment, the main issue involves searching for and connecting to nearby devices. However, if a device can’t find another device that satisfies its requirements, the connection is delayed due to the repetition of processes. It is possible to rapidly connect to a device without repetition through the selection of the optimal device using the proposed method. Consequently, the proposed method and scenarios are advantageous in that they enable efficient content identification and delivery in a content-centric Internet of Things (IoT environment, in which multiple mobile devices coexist.

  7. Effect of internal gettering of iron on electrical characteristics of devices

    International Nuclear Information System (INIS)

    Talvitie, H.; Haarahiltunen, A.; Savin, H.; Yli-Koski, M.; Asghar, M.I.; Sinkkonen, J.

    2009-01-01

    Different types of gettering treatments were applied to a real device process to evaluate their ability to remove iron contamination from the device layer and improve the electrical characteristics of the devices. NMOS and PMOS transistors and other test structures were manufactured on boron doped, both iron contaminated and uncontaminated Cz silicon wafers with or without gettering treatment. Gettering treatments, which were designed to induce sufficient iron precipitate nucleation in the bulk to ensure iron precipitation, were inserted in the fabrication process after the last high temperature treatment in which the iron solubility was higher than the contamination level. The electrical characteristics of the devices, such as leakage currents, were measured. The applied gettering treatments were found to be inefficient to improve the device performance, possibly due to stronger gettering to heavily doped, ion implantation damaged device layer.

  8. Surface wave photonic device based on porous silicon multilayers

    International Nuclear Information System (INIS)

    Guillermain, E.; Lysenko, V.; Benyattou, T.

    2006-01-01

    Porous silicon is widely studied in the field of photonics due to its interesting optical properties. In this work, we present theoretical and first experimental studies of a new kind of porous silicon photonic device based on optical surface wave. A theoretical analysis of the device is presented using plane-wave approximation. The porous silicon multilayered structures are realized using electrochemical etching of p + -type silicon. Morphological and optical characterizations of the realized structures are reported

  9. Graphene device and method of using graphene device

    Science.gov (United States)

    Bouchiat, Vincent; Girit, Caglar; Kessler, Brian; Zettl, Alexander K.

    2015-08-11

    An embodiment of a graphene device includes a layered structure, first and second electrodes, and a dopant island. The layered structure includes a conductive layer, an insulating layer, and a graphene layer. The electrodes are coupled to the graphene layer. The dopant island is coupled to an exposed surface of the graphene layer between the electrodes. An embodiment of a method of using a graphene device includes providing the graphene device. A voltage is applied to the conductive layer of the graphene device. Another embodiment of a method of using a graphene device includes providing the graphene device without the dopant island. A dopant island is placed on an exposed surface of the graphene layer between the electrodes. A voltage is applied to the conductive layer of the graphene device. A response of the dopant island to the voltage is observed.

  10. 30 CFR 18.48 - Circuit-interrupting devices.

    Science.gov (United States)

    2010-07-01

    ... energized. (f) Belt conveyors shall be equipped with control switches to automatically stop the driving motor in the event the belt is stopped, or abnormally slowed down. Note: Short transfer-type conveyors... Design Requirements § 18.48 Circuit-interrupting devices. (a) Each machine shall be equipped with a...

  11. Experiments on a modular magnetic refrigeration device

    DEFF Research Database (Denmark)

    Engelbrecht, Kurt; Jensen, Jesper Buch; Bahl, Christian

    2012-01-01

    of different experiments. The test device is of the reciprocating type, and the magnetic field source is provided by a permanent Halbach magnet assembly with an average flux density of 1.03 Tesla. This work presents experimental results for flat plate regenerators made of gadolinium and sintered compounds...

  12. [Hygienic relevance of devices for indoor air treatment].

    Science.gov (United States)

    Wegner, J

    1982-01-01

    Shortcomings regarding design, construction, operation (including emissions), maintenance/repair and control of buildings with rooms for the accommodation of persons may be the reason to install air conditioning devices. According to manufacturers' data, such devices may be applied for various purposes, e.g. the creation of a defined air temperature or humidity, an increase of the supply of outdoor air, the cleaning and deodorization of indoor air or the alteration of the so-called electric climate of a room. The hygienic health evaluation of the different types of air conditioning devices should establish whether --there are aspects of health necessitating alterations of the microclimate of a room; --such alterations could be brought about in a more economic way by purely constructional or individual measures; --the function of individual apparatuses could be accomplished in a better way by replacing them by a larger device serving several rooms; --the operation of such devices may produce adverse health effects such as nuisance by noise, formation of undesirable gases (ozone), danger owing to non-adherence to electric safety rules; --there will be no damage to rooms and furniture, e.g. by water droplets. A look at a number of commercially available devices shows that they are generally dispensable. There are, however, special rare cases where the use of such devices may result in an improvement of the quality of indoor environments.

  13. Humanitarian Use Devices/Humanitarian Device Exemptions in cardiovascular medicine.

    Science.gov (United States)

    Kaplan, Aaron V; Harvey, Elisa D; Kuntz, Richard E; Shiran, Hadas; Robb, John F; Fitzgerald, Peter

    2005-11-01

    The Second Dartmouth Device Development Symposium held in October 2004 brought together leaders from the medical device community, including clinical investigators, senior representatives from the US Food and Drug Administration, large and small device manufacturers, and representatives from the financial community to examine difficult issues confronting device development. The role of the Humanitarian Use Device/Humanitarian Device Exemption (HUD/HDE) pathway in the development of new cardiovascular devices was discussed in this forum. The HUD/HDE pathway was created by Congress to facilitate the availability of medical devices for "orphan" indications, ie, those affecting HDEs have been granted (23 devices, 6 diagnostic tests). As the costs to gain regulatory approval for commonly used devices increase, companies often seek alternative ways to gain market access, including the HUD/HDE pathway. For a given device, there may be multiple legitimate and distinct indications, including indications that meet the HUD criteria. Companies must choose how and when to pursue each of these indications. The consensus of symposium participants was for the HUD/HDE pathway to be reserved for true orphan indications and not be viewed strategically as part of the clinical development plan to access a large market.

  14. Reactor power control device

    International Nuclear Information System (INIS)

    Ishii, Yoshihiko; Arita, Setsuo; Miyamoto, Yoshiyuki; Fukazawa, Yukihisa; Ishii, Kazuhiko

    1998-01-01

    The present invention provides a reactor power control device capable of enhancing an operation efficiency while keeping high reliability and safety in a BWR type nuclear power plant. Namely, the device of the present invention comprises (1) a means for inputting a set value of a generator power and a set value of a reactor power, (2) a means for controlling the reactor power to either smaller one of the reactor power corresponding to the set value of the generator power and the set value of the reactor power. With such procedures, even if the nuclear power plant is set so as to operate it to make the reactor power 100%, when the generator power reaches the upper limit, the reactor power is controlled with a preference given to the upper limit value of the generator power. Accordingly, safety and reliability are not deteriorated. The operation efficiency of the plant can be improved. (I.S.)

  15. Internal pump monitoring device

    International Nuclear Information System (INIS)

    Kurosaki, Toshikazu.

    1996-01-01

    In the present invention, a thermometer is disposed at the upper end of an internal pump casing of a coolant recycling system in a BWR type reactor to detect leakage of reactor water thereby ensuring the improvement of reliability of the internal pump. Namely, a thermometer is disposed, which can detect temperature elevation occurred when water in the internal pump leaked from a reactor pressure vessel passes through the gap between a stretch tube and an upper end of the pump casing. Signals from the thermometer are transmitted to a signal processing device by an instrumentation cable. The signal processing device generates an alarm when the temperature signal exceeds a predetermined value and announces that leakage of reactor water occurs in the internal pump. Since the present invention can detect the leakage of the reactor water in the pump casing in an early stage, it can contribute to the improvement of the safety and reliability of the internal pump. (I.S.)

  16. Probe-pin device for optical neurotransmitter sensing in the brain

    Science.gov (United States)

    Kim, Min Hyuck; Song, Kyo D.; Yoon, Hargsoon; Park, Yeonjoon; Choi, Sang H.; Lee, Dae-Sung; Shin, Kyu-Sik; Hwang, Hak-In; Lee, Uhn

    2015-04-01

    Development of an optical neurotransmitter sensing device using nano-plasmonic probes and a micro-spectrometer for real time monitoring of neural signals in the brain is underway. Clinical application of this device technology is to provide autonomous closed-loop feedback control to a deep brain stimulation (DBS) system and enhance the accuracy and efficacy of DBS treatment. By far, we have developed an implantable probe-pin device based on localized field enhancement of surface plasmonic resonance on a nanostructured sensing domain which can amplify neurochemical signals from evoked neural activity in the brain. In this paper, we will introduce the details of design and sensing performance of a proto-typed microspectrometer and nanostructured probing devices for real time measurement of neurotransmitter concentrations.

  17. Improved concentration and separation of particles in a 3D dielectrophoretic chip integrating focusing, aligning and trapping

    KAUST Repository

    Li, Ming; Li, Shunbo; Cao, Wenbin; Li, Weihua; Wen, Weijia; Alici, Gursel

    2012-01-01

    This article presents a dielectrophoresis (DEP)-based microfluidic device with the three-dimensional (3D) microelectrode configuration for concentrating and separating particles in a continuous throughflow. The 3D electrode structure, where

  18. Reliability and accuracy of four dental shade-matching devices.

    Science.gov (United States)

    Kim-Pusateri, Seungyee; Brewer, Jane D; Davis, Elaine L; Wee, Alvin G

    2009-03-01

    There are several electronic shade-matching instruments available for clinical use, but the reliability and accuracy of these instruments have not been thoroughly investigated. The purpose of this in vitro study was to evaluate the reliability and accuracy of 4 dental shade-matching instruments in a standardized environment. Four shade-matching devices were tested: SpectroShade, ShadeVision, VITA Easyshade, and ShadeScan. Color measurements were made of 3 commercial shade guides (Vitapan Classical, Vitapan 3D-Master, and Chromascop). Shade tabs were placed in the middle of a gingival matrix (Shofu GUMY) with shade tabs of the same nominal shade from additional shade guides placed on both sides. Measurements were made of the central region of the shade tab positioned inside a black box. For the reliability assessment, each shade tab from each of the 3 shade guide types was measured 10 times. For the accuracy assessment, each shade tab from 10 guides of each of the 3 types evaluated was measured once. Differences in reliability and accuracy were evaluated using the Standard Normal z test (2 sided) (alpha=.05) with Bonferroni correction. Reliability of devices was as follows: ShadeVision, 99.0%; SpectroShade, 96.9%; VITA Easyshade, 96.4%; and ShadeScan, 87.4%. A significant difference in reliability was found between ShadeVision and ShadeScan (P=.008). All other comparisons showed similar reliability. Accuracy of devices was as follows: VITA Easyshade, 92.6%; ShadeVision, 84.8%; SpectroShade, 80.2%; and ShadeScan, 66.8%. Significant differences in accuracy were found between all device pairs (Preliability (over 96%), indicating predictable shade values from repeated measurements. However, there was more variability in accuracy among devices (67-93%), and differences in accuracy were seen with most device comparisons.

  19. Energy sustainable development through energy efficient heating devices and buildings

    International Nuclear Information System (INIS)

    Bojic, M.

    2006-01-01

    Energy devices and buildings are sustainable if, when they operate, they use sustainable (renewable and refuse) energy and generate nega-energy. This paper covers three research examples of this type of sustainability: (1) use of air-to-earth heat exchangers, (2) computer control of heating and cooling of the building (via heat pumps and heat-recovery devices), and (3) design control of energy consumption in a house. (author)

  20. Insulation structure of thermonuclear device

    International Nuclear Information System (INIS)

    Suzuki, Takayuki; Usami, Saburo; Tsukamoto, Hideo; Kikuchi, Mitsuru

    1998-01-01

    The present invention provides an insulating structure of a thermonuclear device, in which insulation materials between toroidal coils are not broken even if superconductive toroidal coils are used. Namely, a tokamak type thermonuclear device of an insulating structure type comprises superconductive toroidal coils for confining plasmas arranged in a circular shape directing the center each at a predetermined angle, and the toroidal coils are insulated from each other. The insulation materials are formed by using a biaxially oriented fiber reinforced plastics. The contact surface of the toroidal coils and the insulating materials are arranged so that they are contact at a woven surface of the fiber reinforced plastics. Either or both of the contact surfaces of the fiber reinforced plastics and the toroidal coils are coated with a high molecular compound having a low friction coefficient. With such a constitution, since the interlayer shearing strength of the biaxially oriented fiber reinforced plastics is about 1/10 of the compression strength, the shearing stress exerted on the insulation material is reduced. Since a static friction coefficient on the contact surface is reduced to provide a structure causing slipping, shearing stress does not exceeds a predetermined limit. As a result, breakage of the insulation materials between the toroidal coils can be prevented. (I.S.)

  1. A New Design of a Single-Device 3D Hall Sensor: Cross-Shaped 3D Hall Sensor

    Directory of Open Access Journals (Sweden)

    Wei Tang

    2018-04-01

    Full Text Available In this paper, a new single-device three-dimensional (3D Hall sensor called a cross-shaped 3D Hall device is designed based on the five-contact vertical Hall device. Some of the device parameters are based on 0.18 μm BCDliteTM technology provided by GLOBALFOUNDRIES. Two-dimensional (2D and 3D finite element models implemented in COMSOL are applied to understand the device behavior under a constant magnetic field. Besides this, the influence of the sensing contacts, active region’s depth, and P-type layers are taken into account by analyzing the distribution of the voltage along the top edge and the current density inside the devices. Due to the short-circuiting effect, the sensing contacts lead to degradation in sensitivities. The P-type layers and a deeper active region in turn are responsible for the improvement of sensitivities. To distinguish the P-type layer from the active region which plays the dominant role in reducing the short-circuiting effect, the current-related sensitivity of the top edge (Stop is defined. It is found that the short-circuiting effect fades as the depth of the active region grows. Despite the P-type layers, the behavior changes a little. When the depth of the active region is 7 μm and the thickness of the P-type layers is 3 μm, the sensitivities in the x, y, and z directions can reach 91.70 V/AT, 92.36 V/AT, and 87.10 V/AT, respectively.

  2. Substrate-bias effect on the breakdown characteristic in a new silicon high-voltage device structure

    International Nuclear Information System (INIS)

    Li Qi; Wang Weidong; Zhao Qiuming; Wei Xueming

    2012-01-01

    A novel silicon double-RESURF LDMOS structure with an improved breakdown characteristic by substrate bias technology (SB) is reported. The P-type epitaxial layer is embedded between an N-type drift region and an N-type substrate to block the conduction path in the off-state and change the distributions of the bulk electric field. The substrate bias strengthens the charge share effect of the drift region near the source, and the vertical electric field peak under the drain is decreased, which is especially helpful in improving the vertical breakdown voltage in a lateral power device with a thin drift region. The numerical results by MEDICI indicate that the breakdown voltage of the proposed device is increased by 97% compared with a conventional LDMOS, while maintaining a lowon-resistance. (semiconductor devices)

  3. Reactor power control device

    International Nuclear Information System (INIS)

    Doi, Kazuyori.

    1981-01-01

    Purpose: To automatically control the BWR type reactor power by simple and short-time searching the load pattern nearest to the required pattern at a nuclear power plant side. Constitution: The reactor power is automatically regulated by periodical modifying of coefficients fitting to a reactor core model, according as a required load pattern. When a load requirement pattern is given, a simulator estimates the total power change and the axial power distribution change from a xenon density change output calculated by a xenon dynamic characteristic estimating device, and a load pattern capable of being realized is searched. The amount to be recirculated is controlled on the basis of the load patteren thus searched, and the operation of the BWR type reactor is automatically controlled at the side of the nuclear power plant. (Kamimura, M.)

  4. Automatic analyzing device for chlorine ion

    International Nuclear Information System (INIS)

    Sugibayashi, Shinji; Morikawa, Yoshitake; Fukase, Kazuo; Kashima, Hiromasa.

    1997-01-01

    The present invention provides a device of automatically analyzing a trance amount of chlorine ions contained in feedwater, condensate and reactor water of a BWR type power plant. Namely, zero-adjustment or span calibration in this device is conducted as follows. (1) A standard chlorine ion liquid is supplied from a tank to a mixer by a constant volume pump, and the liquid is diluted and mixed with purified water to form a standard liquid. (2) The pH of the standard liquid is adjusted by a pH adjuster. (3) The standard liquid is supplied to an electrode cell to conduct zero adjustment or span calibration. Chlorine ions in a specimen are measured by the device of the present invention as follows. (1) The specimen is supplied to a head tank through a line filter. (2) The pH of the specimen is adjusted by a pH adjuster. (3) The specimen is supplied to an electrode cell to electrically measure the concentration of the chlorine ions in the specimen. The device of the present invention can automatically analyze trance amount of chlorine ions at a high accuracy, thereby capable of improving the sensitivity, reducing an operator's burden and radiation exposure. (I.S.)

  5. Strategy Scriptions: On sociomaterial devices staging strategy formulation European Management Journal

    DEFF Research Database (Denmark)

    Friis, Ole Uhrskov

    2014-01-01

    is making strategic choices, then chose a strategy and then making and action plan. Most project groups worked as expected, one group constituting a rare exception, as staging and the mobilisation of devices lead to unanticipated events, triggering extraordinary management activity. Our study shows......Strategy formulation can be viewed as an entanglement of social and material elements, developing sociomaterial strategy devices. Devices contribute to arranging and staging occasions of strategy formulation. The article investigates which arenas are staged for strategy formulation, which types...... of devices is purposely mobilised by management. and consultants. First, one central device, based on a balanced scorecard, is staging the managers as active strategists in a more traditional strategy workshop, with the employees as distanced spectators. Second, the employees are staged in an open space...

  6. The research progress of microdose effect in semiconductor devices

    International Nuclear Information System (INIS)

    Yan Yihua; Fan Ruyu; Guo Xiaoqiang; Lin Dongsheng; Guo Hongxia; Zhang Fengqi; Chen Wei

    2012-01-01

    The localized dose deposited around the track of a heavy ion can be high enough to induce a permanent failure in the semiconductor devices, such as the stuck bit error or functional failure. In this paper, progresses in studies on microdose effect are reviewed. Two basic failure mechanisms, i.e. the localized total dose effect and the strong coulomb repulsive force effect, are discussed. Typical failure modes in several types of devices, and the main impact factors, are discussed, too. (authors)

  7. Simulation of leakage current measurement on medical devices using helmholtz coil configuration with different current flow

    Science.gov (United States)

    Sutanto, E.; Chandra, F.; Dinata, R.

    2017-05-01

    Leakage current measurement which can follow IEC standard for medical device is one of many challenges to be answered. The IEC 60601-1 has defined that the limit for a leakage current for Medical Device can be as low as 10 µA and as high as 500 µA, depending on which type of contact (applied part) connected to the patient. Most people are using ELCB (Earth-leakage circuit breaker) for safety purpose as this is the most common and available safety device in market. One type of ELCB devices is RCD (Residual Current Device) and this RCD type can measure the leakage current directly. This work will show the possibility on how Helmholtz Coil Configuration can be made to be like the RCD. The possibility is explored by comparing the magnetic field formula from each device, then it proceeds with a simulation using software EJS (Easy Java Simulation). The simulation will make sure the concept of magnetic field current cancellation follows the RCD concept. Finally, the possibility of increasing the measurement’s sensitivity is also analyzed. The sensitivity is needed to see the possibility on reaching the minimum leakage current limit defined by IEC, 0.01mA.

  8. Simulation of leakage current measurement on medical devices using helmholtz coil configuration with different current flow

    International Nuclear Information System (INIS)

    Sutanto, E; Chandra, F; Dinata, R

    2017-01-01

    Leakage current measurement which can follow IEC standard for medical device is one of many challenges to be answered. The IEC 60601-1 has defined that the limit for a leakage current for Medical Device can be as low as 10 µA and as high as 500 µA, depending on which type of contact (applied part) connected to the patient. Most people are using ELCB (Earth-leakage circuit breaker) for safety purpose as this is the most common and available safety device in market. One type of ELCB devices is RCD (Residual Current Device) and this RCD type can measure the leakage current directly. This work will show the possibility on how Helmholtz Coil Configuration can be made to be like the RCD. The possibility is explored by comparing the magnetic field formula from each device, then it proceeds with a simulation using software EJS (Easy Java Simulation). The simulation will make sure the concept of magnetic field current cancellation follows the RCD concept. Finally, the possibility of increasing the measurement’s sensitivity is also analyzed. The sensitivity is needed to see the possibility on reaching the minimum leakage current limit defined by IEC, 0.01mA. (paper)

  9. After-heat removing device in nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Mizuno, K [Nippon Atomic Industry Group Co. Ltd., Tokyo

    1977-01-14

    Purpose: To prevent water hammer in a BWR type reactor or the like by moving water in pipe lines having stagnant portions in an after-heat removing device. Constitution: To a reactor container, is provided a recycling pump which constitutes a closed loop type recycling system in a nuclear power plant together with a pressure vessel and pipe lines. A pump and a heat exchanger are provided outside of the reactor container and they are connected to up- and down-streams of the recycling pump to form an after-heat removing device in the plant. Upon shutdown of the nuclear power plant, since water in the stagnant portion flows to the intake port of the recycling pump and water from the reactor is spontaneously supplemented thereafter to the stagnant portion, neither pressurized water nor heated steam is generated and thus water hammer is prevented.

  10. Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device.

    Science.gov (United States)

    Philip, Ranjit; Waller, B Rush; Agrawal, Vijaykumar; Wright, Dena; Arevalo, Alejandro; Zurakowski, David; Sathanandam, Shyam

    2016-02-01

    The aim of this study was to describe and differentiate the morphology of patent ductus arteriosus (PDA) seen in children born prematurely from other PDA types. PDAs are currently classified as types A-E using the Krichenko's classification. Children born prematurely with a PDA morphology that did not fit this classification were described as Type F PDA. A review of 100 consecutive children who underwent transcatheter device closure of PDA was performed. The diameter and length (L) of the PDA and the device diameter (D) were indexed to the descending aorta (DA) diameter. Comparison of 26 Type F PDAs was performed against, 29 Type A, 7 Type C and 32 Type E PDAs. Children with Type F PDAs (median 27.5 weeks gestation) were younger during the device occlusion compared with types A, C, and E (median age: 6 vs. 32, 11, and 42 months; P = 0.002). Type F PDAs were longer and larger, requiring a relatively large device for occlusion than types A, C, and E (Mean L/DA: 1.88 vs. 0.9, 1.21, and 0.89, P ≤ 0.01 and Mean D/DA: 1.04 vs. 0.46, 0.87, and 0.34, P ≤0.01). The Amplatzer vascular plug-II (AVP-II) was preferred for occlusion of Type F PDAs (85%; P <0.001). Children born prematurely have relatively larger and longer PDAs. These "fetal type PDAs" are best classified separately. We propose to classify them as Type F PDAs to add to types A-E currently in use. The AVP-II was effective in occluding Type F PDAs. © 2015 Wiley Periodicals, Inc.

  11. Solution-processed, molecular photovoltaics that exploit hole transfer from non-fullerene, n-type materials

    KAUST Repository

    Douglas, Jessica D.

    2014-05-12

    Solution-processed organic photovoltaic devices containing p-type and non-fullerene n-type small molecules obtain power conversion efficiencies as high as 2.4%. The optoelectronic properties of the n-type material BT(TTI-n12)2 allow these devices to display high open-circuit voltages (>0.85 V) and generate significant charge carriers through hole transfer in addition to the electron-transfer pathway, which is common in fullerene-based devices. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Effects of Mobile Devices on K-12 Students' Achievement: A Meta-Analysis

    Science.gov (United States)

    Tingir, S.; Cavlazoglu, B.; Caliskan, O.; Koklu, O.; Intepe-Tingir, S.

    2017-01-01

    In this meta-analytic study, we investigated the effects of mobile devices on student achievement in science, mathematics and reading in grades K-12. Based on our inclusion criteria, we searched the ERIC and PsycINFO databases and identified 14 peer-reviewed research articles published between 2010 and 2014. We identified the device type, subject…

  13. Twiddlenet: Metadata Tagging and Data Dissemination in Mobile Device Networks

    National Research Council Canada - National Science Library

    Clotfelter, Christopher T; Towle, Jonathon E

    2007-01-01

    .... TwiddleNet is a distributed architecture of personal servers that harnesses the power of these mobile devices, enabling real time information dissemination and file sharing of multiple data types...

  14. DeviceNet-based device-level control in SSRF

    CERN Document Server

    Leng Yong Bin; Lu Cheng Meng; Miao Hai Feng; Liu Song Qiang; Shen Guo Bao

    2002-01-01

    The control system of Shanghai Synchrotron Radiation Facility is an EPICS-based distributed system. One of the key techniques to construct the system is the device-level control. The author describes the design and implementation of the DeviceNet-based device controller. A prototype of the device controller was tested in the experiments of magnet power supply and the result showed a precision of 3 x 10 sup - sup 5

  15. Engineering few-layer MoTe2 devices by Co/hBN tunnel contacts

    Science.gov (United States)

    Zhu, Mengjian; Luo, Wei; Wu, Nannan; Zhang, Xue-ao; Qin, Shiqiao

    2018-04-01

    2H phase Molybdenum ditelluride (MoTe2) is a layered two-dimensional (2D) semiconductor that has recently gained extensive attention for its intriguing properties, demonstrating great potential for nanoelectronics and optoelectronics. Optimizing the electric contacts to MoTe2 is a critical step for realizing high performance devices. Here, we demonstrate Co/hBN tunnel contacts to few-layer MoTe2. In sharp contrast to the p-type conduction of Co contacted MoTe2, Co/hBN tunnel contacted MoTe2 devices show clear n-type transport properties. Our first principles calculation reveals that the inserted few-layer hBN strongly interacts with Co and significantly reduces its work-function by ˜1.2 eV, while MoTe2 itself has a much weaker influence on the work-function of Co. This allows us to build MoTe2 diodes using the mixed Co/hBN and Co contact architecture, which can be switched from p-n type to n-p type by changing the gate-voltage, paving the way for engineering multi-functional devices based on atomically thin 2D semiconductors.

  16. Hybrid superconducting-magnetic memory device using competing order parameters.

    Science.gov (United States)

    Baek, Burm; Rippard, William H; Benz, Samuel P; Russek, Stephen E; Dresselhaus, Paul D

    2014-05-28

    In a hybrid superconducting-magnetic device, two order parameters compete, with one type of order suppressing the other. Recent interest in ultra-low-power, high-density cryogenic memories has spurred new efforts to simultaneously exploit superconducting and magnetic properties so as to create novel switching elements having these two competing orders. Here we describe a reconfigurable two-layer magnetic spin valve integrated within a Josephson junction. Our measurements separate the suppression in the superconducting coupling due to the exchange field in the magnetic layers, which causes depairing of the supercurrent, from the suppression due to the stray magnetic field. The exchange field suppression of the superconducting order parameter is a tunable and switchable behaviour that is also scalable to nanometer device dimensions. These devices demonstrate non-volatile, size-independent switching of Josephson coupling, in magnitude as well as phase, and they may enable practical nanoscale superconducting memory devices.

  17. CHOMIK -Sampling Device of Penetrating Type for Russian Phobos Sample Return Mission

    Science.gov (United States)

    Seweryn, Karol; Grygorczuk, Jerzy; Rickmann, Hans; Morawski, Marek; Aleksashkin, Sergey; Banaszkiewicz, Marek; Drogosz, Michal; Gurgurewicz, Joanna; Kozlov, Oleg E.; Krolikowska-Soltan, Malgorzata; Sutugin, Sergiej E.; Wawrzaszek, Roman; Wisniewski, Lukasz; Zakharov, Alexander

    Measurements of physical properties of planetary bodies allow to determine many important parameters for scientists working in different fields of research. For example effective heat conductivity of the regolith can help with better understanding of processes occurring in the body interior. Chemical and mineralogical composition gives us a chance to better understand the origin and evolution of the moons. In principle such parameters of the planetary bodies can be determined based on three different measurement techniques: (i) in situ measurements (ii) measurements of the samples in laboratory conditions at the Earth and (iii) remote sensing measurements. Scientific missions which allow us to perform all type of measurements, give us a chance for not only parameters determination but also cross calibration of the instruments. Russian Phobos Sample Return (PhSR) mission is one of few which allows for all type of such measurements. The spacecraft will be equipped with remote sensing instruments like: spectrometers, long wave radar and dust counter, instruments for in-situ measurements -gas-chromatograph, seismometer, thermodetector and others and also robotic arm and sampling device. PhSR mission will be launched in November 2011 on board of a launch vehicle Zenit. About a year later (11 months) the vehicle will reach the Martian orbit. It is anticipated that it will land on Phobos in the beginning of 2013. A take off back will take place a month later and the re-entry module containing a capsule that will hold the soil sample enclosed in a container will be on its way back to Earth. The 11 kg re-entry capsule with the container will land in Kazakhstan in mid-2014. A unique geological penetrator CHOMIK dedicated for the Phobos Sample Return space mis-sion will be designed and manufactured at the Space Mechatronics and Robotics Laboratory, Space Research Centre Polish Academy of Sciences (SRC PAS) in Warsaw. Functionally CHOMIK is based on the well known MUPUS

  18. Paper-based device for rapid typing of secondary human blood groups.

    Science.gov (United States)

    Li, Miaosi; Then, Whui Lyn; Li, Lizi; Shen, Wei

    2014-01-01

    We report the use of bioactive paper for typing of secondary human blood groups. Our recent work on using bioactive paper for human blood typing has led to the discovery of a new method for identifying haemagglutination of red blood cells. The primary human blood groups, i.e., ABO and RhD groups, have been successfully typed with this method. Clinically, however, many secondary blood groups can also cause fatal blood transfusion accidents, despite the fact that the haemagglutination reactions of secondary blood groups are generally weaker than those of the primary blood groups. We describe the design of a user-friendly sensor for rapid typing of secondary blood groups using bioactive paper. We also present mechanistic insights into interactions between secondary blood group antibodies and red blood cells obtained using confocal microscopy. Haemagglutination patterns under different conditions are revealed for optimization of the assay conditions.

  19. A new barbed device for repair of flexor tendons.

    LENUS (Irish Health Repository)

    Hirpara, K M

    2012-02-01

    We split 100 porcine flexor tendons into five groups of 20 tendons for repair. Three groups were repaired using the Pennington modified Kessler technique, the cruciate or the Savage technique, one using one new device per tendon and the other with two new devices per tendon. Half of the tendons received supplemental circumferential Silfverskiold type B cross-stitch. The repairs were loaded to failure and a record made of their bulk, the force required to produce a 3 mm gap, the maximum force applied before failure and the stiffness. When only one device was used repairs were equivalent to the Pennington modified Kessler for all parameters except the force to produce a 3 mm gap when supplemented with a circumferential repair, which was equivalent to the cruciate. When two devices were used the repair strength was equivalent to the cruciate repair, and when the two-device repair was supplemented with a circumferential suture the force to produce a 3 mm gap was equivalent to that of the Savage six-strand technique.

  20. Minimizing exposure in nuclear medicine through optimum use of shielding devices

    International Nuclear Information System (INIS)

    Rutherford, B.L.; King, S.H.; Erdman, M.C.; Miller, K.L.

    1991-01-01

    Exposure to radiation from nuclear medicine nuclides can be minimized through the use of various shielding devices. This paper reviews the dose reductions achieved through use of various syringe shields, lead aprons, leaded gloves, and several types of eyeglass lenses for 67 Ga, 99m Tc, 131 I and 201 Tl. The authors have found that combination of devices can best provide for minimizing doses

  1. Simple and inexpensive microfluidic devices for the generation of monodisperse multiple emulsions

    KAUST Repository

    Li, Erqiang

    2013-12-16

    Droplet-based microfluidic devices have become a preferred versatile platform for various fields in physics, chemistry and biology. Polydimethylsiloxane soft lithography, the mainstay for fabricating microfluidic devices, usually requires the usage of expensive apparatus and a complex manufacturing procedure. Here, we report the design and fabrication of simple and inexpensive microfluidic devices based on microscope glass slides and pulled glass capillaries, for generating monodisperse multiple emulsions. The advantages of our method lie in a simple manufacturing procedure, inexpensive processing equipment and flexibility in the surface modification of the designed microfluidic devices. Different types of devices have been designed and tested and the experimental results demonstrated their robustness for preparing monodisperse single, double, triple and multi-component emulsions. © 2014 IOP Publishing Ltd.

  2. Elmo Bumpy Torus proof of principle, Phase II: Title 1 report. Volume VIII. Device utilities

    International Nuclear Information System (INIS)

    Erickson, D.T.

    1982-01-01

    This report describes the activities conducted during the Preliminary Design Period for the Device Utilities Systems. All GAI preliminary specifications, drawings, and reports (listed in Section 4.0) have been transmitted to ORNL for review and approval. Device Utility Systems Descriptions are also presented in Section 4.0. The GAI Device Enclosure Gamma Radiation Analysis is presented in Appendix B. Pending design criteria revisions are described in Section 6.0. A type B Change Notice Request (CNR) has been transmitted to GAI. The Type B CNR authorizes cost and schedule assessment for each revision identified. Formal Proposed Design Changes (PDC's) will be provided to ORNL when this data is available

  3. Intelligent micro blood typing system using a fuzzy algorithm

    International Nuclear Information System (INIS)

    Kang, Taeyun; Cho, Dong-Woo; Lee, Seung-Jae; Kim, Yonggoo; Lee, Gyoo-Whung

    2010-01-01

    ABO typing is the first analysis performed on blood when it is tested for transfusion purposes. The automated machines used in hospitals for this purpose are typically very large and the process is complicated. In this paper, we present a new micro blood typing system that is an improved version of our previous system (Kang et al 2004 Trans. ASME, J. Manuf. Sci. Eng. 126 766, Lee et al 2005 Sensors Mater. 17 113). This system, fabricated using microstereolithography, has a passive valve for controlling the flow of blood and antibodies. The intelligent micro blood typing system has two parts: a single-line micro blood typing device and a fuzzy expert system for grading the strength of agglutination. The passive valve in the single-line micro blood typing device makes the blood stop at the entrance of a micro mixer and lets it flow again after the blood encounters antibodies. Blood and antibodies are mixed in the micro mixer and agglutination occurs in the chamber. The fuzzy expert system then determines the degree of agglutination from images of the agglutinated blood. Blood typing experiments using this device were successful, and the fuzzy expert system produces a grading decision comparable to that produced by an expert conducting a manual analysis

  4. Processes in construction of failure management expert systems from device design information

    Science.gov (United States)

    Malin, Jane T.; Lance, Nick

    1987-01-01

    This paper analyzes the tasks and problem solving methods used by an engineer in constructing a failure management expert system from design information about the device to te diagnosed. An expert test engineer developed a trouble-shooting expert system based on device design information and experience with similar devices, rather than on specific expert knowledge gained from operating the device or troubleshooting its failures. The construction of the expert system was intensively observed and analyzed. This paper characterizes the knowledge, tasks, methods, and design decisions involved in constructing this type of expert system, and makes recommendations concerning tools for aiding and automating construction of such systems.

  5. Development of a Very High Cycle Fatigue (VHCF multiaxial testing device

    Directory of Open Access Journals (Sweden)

    M. Vieira

    2016-07-01

    Full Text Available The very high cycle region of the S-N fatigue curve has been the subject of intensive research on the last years, with special focus on axial, bending, torsional and fretting fatigue tests. Very high cycle fatigue can be achieved using ultrasonic exciters which allow for frequency testing of up to 30 kHz. Still, the multiaxial fatigue analysis is not yet developed for this type of fatigue analyses, mainly due to conceptual limitations of these testing devices. In this paper, a device designed to produce biaxial fatigue testing using a single piezoelectric axial exciter is presented, as well as the preliminary testing of this device. The device is comprised of a horn and a specimen, which are both attached to the piezoelectric exciter. The steps taken towards the final geometry of the device are presented. Preliminary experimental testing of the developed device is made using thermographic imaging, strain measurements and vibration speeds and indicates good behaviour of the tested specimen.

  6. Pharmaceutical counselling about different types of tablet-splitting methods based on the results of weighing tests and mechanical development of splitting devices.

    Science.gov (United States)

    Somogyi, O; Meskó, A; Csorba, L; Szabó, P; Zelkó, R

    2017-08-30

    The division of tablets and adequate methods of splitting them are a complex problem in all sectors of health care. Although tablet-splitting is often required, this procedure can be difficult for patients. Four tablets were investigated with different external features (shape, score-line, film-coat and size). The influencing effect of these features and the splitting methods was investigated according to the precision and "weight loss" of splitting techniques. All four types of tablets were halved by four methods: by hand, with a kitchen knife, with an original manufactured splitting device and with a modified tablet splitter based on a self-developed mechanical model. The mechanical parameters (harness and friability) of the products were measured during the study. The "weight loss" and precision of splitting methods were determined and compared by statistical analysis. On the basis of the results, the external features (geometry), the mechanical parameters of tablets and the mechanical structure of splitting devices can influence the "weight loss" and precision of tablet-splitting. Accordingly, a new decision-making scheme was developed for the selection of splitting methods. In addition, the skills of patients and the specialties of therapy should be considered so that pharmaceutical counselling can be more effective regarding tablet-splitting. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Motorcycle safety device investigation: A case study on airbags

    Indian Academy of Sciences (India)

    analysis methods for research evaluation of rider crash protective devices fitted to ... The safety evaluation is then based on simulation of the 200 impact types. ... with recording of ISO 13232 car-front impact tests to evaluate the qualitative.

  8. On-Demand Cell Internal Short Circuit Device

    Science.gov (United States)

    Darcy, Eric; Keyser, Matthew

    2014-01-01

    A device implantable in Li-ion cells that can generate a hard internal short circuit on-demand by exposing the cell to 60?C has been demonstrated to be valuable for expanding our understanding of cell responses. The device provides a negligible impact to cell performance and enables the instigation of the 4 general categories of cell internal shorts to determine relative severity and cell design susceptibility. Tests with a 18650 cell design indicates that the anode active material short to the aluminum cathode current collector tends to be more catastrophic than the 3 other types of internal shorts. Advanced safety features (such as shutdown separators) to prevent or mitigate the severity of cell internal shorts can be verified with this device. The hard short success rate achieved to date in 18650 cells is about 80%, which is sufficient for using these cells in battery assemblies for field-failure-relevant, cell-cell thermal runaway propagation verification tests

  9. 40 CFR 63.693 - Standards: Closed-vent systems and control devices.

    Science.gov (United States)

    2010-07-01

    ... concentration level, design average temperature of the condenser exhaust vent stream, and the design average... requirements specified in paragraphs (d) through (h) of this section as applicable to the type and design of... paragraphs (d) through (h) of this section as applicable to the type and design of the control device...

  10. Single Event Effects in FPGA Devices 2015-2016

    Science.gov (United States)

    Berg, Melanie; LaBel, Kenneth; Pellish, Jonathan

    2016-01-01

    This presentation provides an overview of single event effects in FPGA devices 2015-2016 including commercial Xilinx V5 heavy ion accelerated testing, Xilinx Kintex-7 heavy ion accelerated testing, mitigation study, and investigation of various types of triple modular redundancy (TMR) for commercial SRAM based FPGAs.

  11. Device-Independent Certification of a Nonprojective Qubit Measurement

    Science.gov (United States)

    Gómez, Esteban S.; Gómez, Santiago; González, Pablo; Cañas, Gustavo; Barra, Johanna F.; Delgado, Aldo; Xavier, Guilherme B.; Cabello, Adán; Kleinmann, Matthias; Vértesi, Tamás; Lima, Gustavo

    2016-12-01

    Quantum measurements on a two-level system can have more than two independent outcomes, and in this case, the measurement cannot be projective. Measurements of this general type are essential to an operational approach to quantum theory, but so far, the nonprojective character of a measurement can only be verified experimentally by already assuming a specific quantum model of parts of the experimental setup. Here, we overcome this restriction by using a device-independent approach. In an experiment on pairs of polarization-entangled photonic qubits we violate by more than 8 standard deviations a Bell-like correlation inequality that is valid for all sets of two-outcome measurements in any dimension. We combine this with a device-independent verification that the system is best described by two qubits, which therefore constitutes the first device-independent certification of a nonprojective quantum measurement.

  12. Measurement Devices and the Psychophysiology of Consumer Behaviour

    DEFF Research Database (Denmark)

    Schwarzkopf, Stefan

    2015-01-01

    of the type of subjectivity that underlies consumer behaviour. I argue instead that a posthuman view of the relationship between brain, mind and behaviour underpinned neurophysiological research into consumers from its very beginning in the late nineteenth century. By tracing the biopolitical potentialities...... of neuromarketing back to the Fin-de-Siècle neurophysiological laboratory, I show that consumers' bodies and later on their brains became reconfigured as part of a dispositif made up of laboratory-based artefacts (measurement devices) and new ways of seeing the human brain and human behaviour. This dispositif......From the 1890s, psychophysiological measurement devices have played an important, but as yet under-theorized role in marketing and consumer research. Because of the recent advances made in neuromarketing, it is often assumed that these measurement devices ushered in a radically new understanding...

  13. Device for the alternative option of temperature measurement

    Science.gov (United States)

    Jargus, Jan; Nedoma, Jan; Fajkus, Marcel; Novak, Martin; Cubik, Jakub; Cvejn, Daniel; Vasinek, Vladimir

    2017-10-01

    Polydimethylsiloxane (PDMS) has good optical properties, and its composition offers the possibility of use in many applications (industry, security device, medicine applications and etc.). We focused on the alternative option of temperature measurement in this article. Our approach is based on measuring changes of chromaticity correlated temperature corresponding to changes in temperature. Described device uses an optical fiber with a defined layer of PDMS and luminophore and we assume that it can find use also in the field of security. The article describes the process of making the prototype of the device and its verification based on laboratory results. The measured temperature depends mainly on the type of optical fiber and the measured temperature range is determined by the thermal resistance of used optical fiber. Using a calibration measurement can determine the value of temperature with an accuracy of +/- 2,5 %.

  14. Supporting device for Toroidal coils

    International Nuclear Information System (INIS)

    Araki, Takao.

    1985-01-01

    Purpose: To reduce the response of a toroidal coil supporting device upon earthquakes and improve the earthquake proofness in a tokamak type thermonuclear device. Constitution: Structural materials having large longitudinal modulus and enduring great stresses, for example, stainless steels are used as the toroidal coil supporting legs and heat insulating structural materials are embedded in a nuclear reactor base mats below the supporting legs. Furthermore, heat insulating concretes are spiked around the heat insulating structural materials to prevent the intrusion of heat to the toroidal coils. The toroidal coils are kept at cryogenic state and superconductive state for the conductors. In this way, the period of proper vibrations of the toroidal coils and the toroidal coil supporting structures can be shortened thereby decreasing the seismic response. Furthermore, since the strength of the supporting legs is increased, the earthquake proofness of the coils can be improved. (Kamimura, M.)

  15. Filtering device for primary coolant circuits in BWR type reactors

    International Nuclear Information System (INIS)

    Tajima, Fumio; Yamamoto, Tetsuo.

    1985-01-01

    Purpose: To obtain a filtering device with a large filtering area and requiring less space. Constitution: A condensate inlet for introducing condensates to be filtered of primary coolant circuits, a filtrate exit, a backwash water exit and a bent tube are disposed to a container, and a plurality of hollow thread membrane modules are suspended in the container. The condensates are caused to flow through the condensate inlet, filtered through the hollow thread membrane and then discharged from the filtrate exit. When the filtering treatment is proceeded to some extent, since solid contents captured in the hollow thread membranes are accumulated, a differential pressure is produced between the condensate inlet and the filtrate exit. When the differential pressure reaches a predetermined value, the backwash is conducted to discharge the liquid cleaning wastes through the backwash exit. The bent tube disposed to the container body is used for water and air draining. The hollow thread membranes are formed with porous resin such as of polyethylene. (Kawakami, Y.)

  16. Standardization of splash device

    Science.gov (United States)

    Fernández Raga, María; Peters, Piet

    2017-04-01

    The erosion is a complex process that has been studied extensively by numerous researchers, requiring a prolongued time effort and a large economic investment. To be effective, the measurements of erosion should be precise, controlled and replicable, and to assure efectiveness, measurement devices of erosion should be properly designed, constructed, well calibrated and also they should be operated by a trained person (Stroosnijder, 2005). Because researchers try to improve old devices, the equipment is constantly being redesigned, making the measurements not comparable and furthermore, producing a lack of available standarized device. The lack of standardization of erosion equipment is more obvious in the case of the local splash erosion, where the nature of the process makes very difficult to isolate its effects. In this article we compare the results obtained from five of the most common splash erosion devices (selected from more than 16 different currently types), under the same rain conditions, with the objective of facilitate the standardization of the method that will be more easy to build, minimizing the error. A set of six splash devices were setted in well known positions under simulated rain, to measured the differences, among devices and the accuracy of the data recovered after 10 minutes of rainfall simulation under different intensities (from 60 to 130 mm/h). The rainfall simulator of Wageningen was used, using sand as splash erosion source. Differences in the infiltration were also measured, and a calibration of sizes and speeds of the raindrops was done using the photography method (Hamidreza-Sadeghi et al., 2013). The splash devices selected for this study were unbounded splash devices (like the funnel, the cup (Fernandez-Raga et al., 2010) and the splash flume (Jomaa et al., 2010)), and bounded devices that allow the calculation of splash rate, (like the new cup (Scholten et al., 2011) and the Morgan tray). The behaviour of different splash devices

  17. Recent Advances on p-Type III-Nitride Nanowires by Molecular Beam Epitaxy

    Directory of Open Access Journals (Sweden)

    Songrui Zhao

    2017-09-01

    Full Text Available p-Type doping represents a key step towards III-nitride (InN, GaN, AlN optoelectronic devices. In the past, tremendous efforts have been devoted to obtaining high quality p-type III-nitrides, and extraordinary progress has been made in both materials and device aspects. In this article, we intend to discuss a small portion of these processes, focusing on the molecular beam epitaxy (MBE-grown p-type InN and AlN—two bottleneck material systems that limit the development of III-nitride near-infrared and deep ultraviolet (UV optoelectronic devices. We will show that by using MBE-grown nanowire structures, the long-lasting p-type doping challenges of InN and AlN can be largely addressed. New aspects of MBE growth of III-nitride nanostructures are also discussed.

  18. Photovoltaic device on a single ZnO nanowire p–n homojunction

    International Nuclear Information System (INIS)

    Cho, Hak Dong; Zakirov, Anvar S; Yuldashev, Shavkat U; Kang, Tae Won; Ahn, Chi Won; Yeo, Yung Kee

    2012-01-01

    A photovoltaic device was successfully grown solely based on the single ZnO p–n homojunction nanowire. The ZnO nanowire p–n diode consists of an as-grown n-type segment and an in situ arsenic-doped p-type segment. This p–n homojunction acts as a good photovoltaic cell, producing a photocurrent almost 45 times larger than the dark current under reverse-biased conditions. Our results demonstrate that the present ZnO p–n homojunction nanowire can be used as a self-powered ultraviolet photodetector as well as a photovoltaic cell, which can also be used as an ultralow electrical power source for nanoscale electronic, optoelectronic and medical devices. (paper)

  19. QoE-Aware Device-to-Device Multimedia Communications

    Directory of Open Access Journals (Sweden)

    Liang ZHOU

    2015-08-01

    Full Text Available Multimedia services over mobile device-to-device (D2D networks has recently received considerable attention. In this scenario, each device is equipped with a cellular communication interface, as well as a D2D interface over a shared medium. In this work, we study the performance properties of the mobile D2D communications in the framework of user satisfaction, and develop a fully distributed QoE-aware multimedia communication scheme (QAMCS. Specifically, we translate the opportunistic multimedia communications issue into a stochastic optimization problem, which opens up a new degree of performance to exploit. Moreover, QAMCS is designed for a heterogeneous and dynamic environment, in which user demand, device mobility, and transmission fashion may vary across different devices and applications. Importantly, QAMCS is able to maximize the user satisfaction and only needs each device to implement its own scheme individually in the absence of a central controller.

  20. Device for measuring the flow rate of a fluid moving through a pipe

    International Nuclear Information System (INIS)

    Barge, Gilles; Bouchard, Patrick; Chaix, J.E.; Rigaud, J.L.; Vivaldi, Andre.

    1981-01-01

    A device is described for measuring the flow rate, in particular through large section pipes, such as those found in water type nuclear reactors, thermal power stations and gas loops. This device includes a plate drilled with holes crossed by a fluid and held in the pipe by deformable components on which are secured strain gauges forming the detecting element of an electronic device for processing the signal emitted by the gauges. This device can be employed, for instance, for measuring the flow rate of a coolant in the primary system of a nuclear reactor [fr

  1. CMOS-compatible spintronic devices: a review

    Science.gov (United States)

    Makarov, Alexander; Windbacher, Thomas; Sverdlov, Viktor; Selberherr, Siegfried

    2016-11-01

    For many decades CMOS devices have been successfully scaled down to achieve higher speed and increased performance of integrated circuits at lower cost. Today’s charge-based CMOS electronics encounters two major challenges: power dissipation and variability. Spintronics is a rapidly evolving research and development field, which offers a potential solution to these issues by introducing novel ‘more than Moore’ devices. Spin-based magnetoresistive random-access memory (MRAM) is already recognized as one of the most promising candidates for future universal memory. Magnetic tunnel junctions, the main elements of MRAM cells, can also be used to build logic-in-memory circuits with non-volatile storage elements on top of CMOS logic circuits, as well as versatile compact on-chip oscillators with low power consumption. We give an overview of CMOS-compatible spintronics applications. First, we present a brief introduction to the physical background considering such effects as magnetoresistance, spin-transfer torque (STT), spin Hall effect, and magnetoelectric effects. We continue with a comprehensive review of the state-of-the-art spintronic devices for memory applications (STT-MRAM, domain wall-motion MRAM, and spin-orbit torque MRAM), oscillators (spin torque oscillators and spin Hall nano-oscillators), logic (logic-in-memory, all-spin logic, and buffered magnetic logic gate grid), sensors, and random number generators. Devices with different types of resistivity switching are analyzed and compared, with their advantages highlighted and challenges revealed. CMOS-compatible spintronic devices are demonstrated beginning with predictive simulations, proceeding to their experimental confirmation and realization, and finalized by the current status of application in modern integrated systems and circuits. We conclude the review with an outlook, where we share our vision on the future applications of the prospective devices in the area.

  2. Virtual MIMO Beamforming and Device Pairing Enabled by Device-to-Device Communications for Multidevice Networks

    Directory of Open Access Journals (Sweden)

    Yeonjin Jeong

    2017-01-01

    Full Text Available We consider a multidevice network with asymmetric antenna configurations which supports not only communications between an access point and devices but also device-to-device (D2D communications for the Internet of things. For the network, we propose the transmit and receive beamforming with the channel state information (CSI for virtual multiple-input multiple-output (MIMO enabled by D2D receive cooperation. We analyze the sum rate achieved by a device pair in the proposed method and identify the strategies to improve the sum rate of the device pair. We next present a distributed algorithm and its equivalent algorithm for device pairing to maximize the throughput of the multidevice network. Simulation results confirm the advantages of the transmit CSI and D2D cooperation as well as the validity of the distributive algorithm.

  3. Tank type LMFBR type reactors

    International Nuclear Information System (INIS)

    Shimizu, Hiroshi

    1985-01-01

    Purpose: To detect the abnormality in the suspended body or reactor core supporting structures thereby improve the safety and reliability of tank type LMFBR reactors. Constitution: Upon inspection during reactor operation period, the top end of the gripper sensing rod of a fuel exchanger is abutted against a supporting bed and the position of the reactor core supporting structures from the roof slab is measured by a stroke measuring device. Then, the sensing rod is pulled upwardly to abut against the arm portion and the position is measured by the stroke measuring device. The measuring procedures are carried out for all of the sensing rods and the measured values are compared with a previously determined value at the initial stage of the reactor operation. As a result, it is possible to detect excess distortions and abnormal deformation in the suspended body or reactor core supporting structures. Furthermore, integrity of the suspended body against thermal stresses can be secured by always measuring the coolant liquid level by the level measuring sensor. (Kamimura, M.)

  4. Plasma membrane characterization, by scanning electron microscopy, of multipotent myoblasts-derived populations sorted using dielectrophoresis.

    Science.gov (United States)

    Muratore, Massimo; Mitchell, Steve; Waterfall, Martin

    2013-09-06

    Multipotent progenitor cells have shown promise for use in biomedical applications and regenerative medicine. The implementation of such cells for clinical application requires a synchronized, phenotypically and/or genotypically, homogenous cell population. Here we have demonstrated the implementation of a biological tag-free dielectrophoretic device used for discrimination of multipotent myoblastic C2C12 model. The multipotent capabilities in differentiation, for these cells, diminishes with higher passage number, so for cultures above 70 passages only a small percentage of cells is able to differentiate into terminal myotubes. In this work we demonstrated that we could recover, above 96% purity, specific cell types from a mixed population of cells at high passage number without any biological tag using dielectrophoresis. The purity of the samples was confirmed by cytometric analysis using the cell specific marker embryonic myosin. To further investigate the dielectric properties of the cell plasma membrane we co-culture C2C12 with similar size, when in suspension, GFP-positive fibroblast as feeder layer. The level of separation between the cell types was above 98% purity which was confirmed by flow cytometry. These levels of separation are assumed to account for cell size and for the plasma membrane morphological differences between C2C12 and fibroblast unrelated to the stages of the cell cycle which was assessed by immunofluorescence staining. Plasma membrane conformational differences were further confirmed by scanning electron microscopy. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Mixed-Dimensionality VLSI-Type Configurable Tools for Virtual Prototyping of Biomicrofluidic Devices and Integrated Systems

    National Research Council Canada - National Science Library

    Makhijani, Vinod

    2002-01-01

    ...+ Multiphysics, for bio and microfluidic devices and complete microsystems. The project began in July 1998, and was a three-year team effort between CFD Research Corporation, California Institute of Technology (CalTech...

  6. Improving the accuracy of smart devices to measure noise exposure.

    Science.gov (United States)

    Roberts, Benjamin; Kardous, Chucri; Neitzel, Richard

    2016-11-01

    Occupational noise exposure is one of the most frequent hazards present in the workplace; up to 22 million workers have potentially hazardous noise exposures in the U.S. As a result, noise-induced hearing loss is one of the most common occupational injuries in the U.S. Workers in manufacturing, construction, and the military are at the highest risk for hearing loss. Despite the large number of people exposed to high levels of noise at work, many occupations have not been adequately evaluated for noise exposure. The objective of this experiment was to investigate whether or not iOS smartphones and other smart devices (Apple iPhones and iPods) could be used as reliable instruments to measure noise exposures. For this experiment three different types of microphones were tested with a single model of iPod and three generations of iPhones: the internal microphones on the device, a low-end lapel microphone, and a high-end lapel microphone marketed as being compliant with the International Electrotechnical Commission's (IEC) standard for a Class 2-microphone. All possible combinations of microphones and noise measurement applications were tested in a controlled environment using several different levels of pink noise ranging from 60-100 dBA. Results were compared to simultaneous measurements made using a Type 1 sound level measurement system. Analysis of variance and Tukey's honest significant difference (HSD) test were used to determine if the results differed by microphone or noise measurement application. Levels measured with external microphones combined with certain noise measurement applications did not differ significantly from levels measured with the Type 1 sound measurement system. Results showed that it may be possible to use iOS smartphones and smart devices, with specific combinations of measurement applications and calibrated external microphones, to collect reliable, occupational noise exposure data under certain conditions and within the limitations of the

  7. Experimental Research of a New Wave Energy Conversion Device

    Science.gov (United States)

    Lu, Zhongyue; Shang, Jianzhong; Luo, Zirong; Sun, Chongfei; Chen, Gewei

    2018-01-01

    With the increasing tension of contemporary social energy, the development and utilization of renewable energy has become an important development direction. As an important part of renewable energy, wave energy has the characteristics of green environmental protection and abundant reserves, attracting more investment and research. For small marine equipment energy supply problem, this paper puts forward a micro wave energy conversion device as the basic of heaving motion of waves in the ocean. This paper designed a new type of power output device can solve the micro wave energy conversion problem.

  8. Design of practical alignment device in KSTAR Thomson diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. H., E-mail: jhlee@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); University of Science and Technology (UST), Daejeon (Korea, Republic of); Lee, S. H. [National Fusion Research Institute, Daejeon (Korea, Republic of); Yamada, I. [National Institute for Fusion Science, Toki (Japan)

    2016-11-15

    The precise alignment of the laser path and collection optics in Thomson scattering measurements is essential for accurately determining electron temperature and density in tokamak experiments. For the last five years, during the development stage, the KSTAR tokamak’s Thomson diagnostic system has had alignment fibers installed in its optical collection modules, but these lacked a proper alignment detection system. In order to address these difficulties, an alignment verifying detection device between lasers and an object field of collection optics is developed. The alignment detection device utilizes two types of filters: a narrow laser band wavelength for laser, and a broad wavelength filter for Thomson scattering signal. Four such alignment detection devices have been successfully developed for the KSTAR Thomson scattering system in this year, and these will be tested in KSTAR experiments in 2016. In this paper, we present the newly developed alignment detection device for KSTAR’s Thomson scattering diagnostics.

  9. Designing Mixed Media Devices for support of healthcare professionals

    DEFF Research Database (Denmark)

    Kramp, Gunnar

    2008-01-01

    at tilføje en lokation til et fotografi. I denne afhandling betegnes denne type objekter som Mixed-Media-Devices på grund af deres heterogene natur.   For at Mixed-Media-Devices kan forbinde sig til hinanden, er det nødvendigt med en software arkitektur, som understøtter denne heterogenitet. Ydermere, må......”. Med andre ord, at udvikle den nødvendige software til at kunne orkestrere de fremspirende Mixed-Media-Devices i vores omgivelser. Arbejdet, der ligger til grund for denne afhandling er, blevet til indenfor Palcom projektets rammer.   Palcom projektet koordineres af Datalogi på Århus Universitet...... virkelighedens brugere har Palcom projektet arbejdet med en række indsatsområder som katastrofeindsats, graviditet og barsel, hånd-kirurgi og en neonatal afdeling. Sammen med brugerne fra disse områder er der udviklet en række Mixed-Media-Devices med henblik på at informere om og afprøve den udviklede software...

  10. Release strategies for making transferable semiconductor structures, devices and device components

    Science.gov (United States)

    Rogers, John A; Nuzzo, Ralph G; Meitl, Matthew; Ko, Heung Cho; Yoon, Jongseung; Menard, Etienne; Baca, Alfred J

    2014-11-25

    Provided are methods for making a device or device component by providing a multilayer structure having a plurality of functional layers and a plurality of release layers and releasing the functional layers from the multilayer structure by separating one or more of the release layers to generate a plurality of transferable structures. The transferable structures are printed onto a device substrate or device component supported by a device substrate. The methods and systems provide means for making high-quality and low-cost photovoltaic devices, transferable semiconductor structures, (opto-)electronic devices and device components.

  11. 21 CFR 876.5540 - Blood access device and accessories.

    Science.gov (United States)

    2010-04-01

    ... vascular graft prosthesis (§§ 870.3450 and 870.3460), and are intended to remain in the body for less than... intended to remain in the body for 30 days or more. This generic type of device includes various shunts and...

  12. Equivalent Circuit Analysis of Photovoltaic-Thermoelectric Hybrid Device with Different TE Module Structure

    Directory of Open Access Journals (Sweden)

    Haijun Chen

    2014-01-01

    Full Text Available Combining two different types of solar cells with different absorption bands into a hybrid cell is a very useful method to improve the utilization efficiency of solar energy. The experimental data of dye-sensitized solar cells (DSSCs and thermoelectric generators (TEG was simulated by equivalent circuit method, and some parameters of DSSCs were obtained. Then, the equivalent circuit model with the obtained parameters was used to optimize the structure design of photovoltaic- (PV- thermoelectric (TE hybrid devices. The output power (Pout first increases to a maximum and then decreases by increasing the TE prism size, and a smaller spacing between p-type prism and n-type prism of a TE p-n junction causes a higher output power of TEG and hybrid device. When the spacing between TE prisms is 15 μm and the optimal base side length of TE prism is 40 μm, the maximum theoretical efficiency reaches 24.6% according to the equivalent circuit analysis. This work would give some enlightenment for the development of high-performance PV-TE hybrid devices.

  13. Particle interaction and displacement damage in silicon devices operated in radiation environments

    International Nuclear Information System (INIS)

    Leroy, Claude; Rancoita, Pier-Giorgio

    2007-01-01

    Silicon is used in radiation detectors and electronic devices. Nowadays, these devices achieving submicron technology are parts of integrated circuits of large to very large scale integration (VLSI). Silicon and silicon-based devices are commonly operated in many fields including particle physics experiments, nuclear medicine and space. Some of these fields present adverse radiation environments that may affect the operation of the devices. The particle energy deposition mechanisms by ionization and non-ionization processes are reviewed as well as the radiation-induced damage and its effect on device parameters evolution, depending on particle type, energy and fluence. The temporary or permanent damage inflicted by a single particle (single event effect) to electronic devices or integrated circuits is treated separately from the total ionizing dose (TID) effect for which the accumulated fluence causes degradation and from the displacement damage induced by the non-ionizing energy-loss (NIEL) deposition. Understanding of radiation effects on silicon devices has an impact on their design and allows the prediction of a specific device behaviour when exposed to a radiation field of interest

  14. Design and fabrication of an energy-harvesting device using vibration absorber

    Science.gov (United States)

    Heidari, Hamidreza; Afifi, Arash

    2017-05-01

    Energy-harvesting devices collect energy that is being wasted and convert to the electrical energy. For this reason, this type of devices is considered as a convenient alternative to traditional batteries. In this paper, experimental examinations were performed to investigate the application of harvesting device for the reduction of the vibration amplitude in a vibration system and also increase the efficiency of energy-harvesting device. This study focuses on the energy-harvesting device as both producing electrical device and a vibration disabled absorber. In this regard, a motion-based energy-harvesting device is designed to produce electrical energy and also eliminate vibrations of a two joint-end beam which is located under the harmonic excitation force. Then, the governing equations of the forced motion on the main beam are derived and energy-harvesting system are simulated. In addition, the system designed by MATLAB simulation is explained and its results are expressed. Finally, a prototype of the system was made and the ability of the energy-harvesting device to absorb the original system vibrations, as well as parameters impact on the efficiency of energy harvesting is investigated. Experimental results show that the energy-harvesting device, in addition to producing electric current with a maximum value of 1.5V, reduces 94% of the original system vibrations.

  15. Features of the use of charge-coupled devices in emission spectroscopic analysis

    International Nuclear Information System (INIS)

    Livshits, A.M.; Peleznev, A.V.

    1993-01-01

    Multielement radiation receivers based on linear charge-coupled photodiode devices have become more aand more widely used recently in spectroscopic analysis. The main feature of such receivers is their ability to record not only the intensity of the incident light flux, but also its spatial distribution. This article considers the advantages and disadvantages of charge-coupled devices when used in emission spectroscopic analysis. The main methods nd devices employed for this purpose and discussed here can be divided into four types: photographic photometry, visual styloscopy, quantometry, and successive analysis. 4 refs., 1 fig

  16. Dismantling and chemical characterization of spent Peltier thermoelectric devices for antimony, bismuth and tellurium recovery.

    Science.gov (United States)

    Balva, Maxime; Legeai, Sophie; Garoux, Laetitia; Leclerc, Nathalie; Meux, Eric

    2017-04-01

    Major uses of thermoelectricity concern refrigeration purposes, using Peltier devices, mainly composed of antimony, bismuth and tellurium. Antimony was identified as a critical raw material by EU and resources of bismuth and tellurium are not inexhaustible, so it is necessary to imagine the recycling of thermoelectric devices. That for, a complete characterization is needed, which is the aim of this work. Peltier devices were manually dismantled in three parts: the thermoelectric legs, the alumina plates on which remain the electrical contacts and the silicone paste used to connect the plates. The characterization was performed using five Peltier devices. It includes mass balances of the components, X-ray diffraction analysis of the thermoelectric legs and elemental analysis of each part of the device. It appears that alumina represents 45% of a Peltier device in weight. The electrical contacts are mainly composed of copper and tin, and the thermoelectric legs of bismuth, tellurium and antimony. Thermoelectric legs appear to be Se-doped Bi 2 Te 3 and (Bi 0,5 Sb 1,5 )Te 3 for n type and p type semiconductors, respectively. This work shows that Peltier devices can be considered as a copper ore and that thermoelectric legs contain high amounts of bismuth, tellurium and antimony compared to their traditional resources.

  17. Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture

    Science.gov (United States)

    McCown, Steven H [Rigby, ID; Derr, Kurt W [Idaho Falls, ID; Rohde, Kenneth W [Idaho Falls, ID

    2012-05-08

    Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture are described. According to one embodiment, a wireless device monitoring method includes accessing device configuration information of a wireless device present at a secure area, wherein the device configuration information comprises information regarding a configuration of the wireless device, accessing stored information corresponding to the wireless device, wherein the stored information comprises information regarding the configuration of the wireless device, comparing the device configuration information with the stored information, and indicating the wireless device as one of authorized and unauthorized for presence at the secure area using the comparing.

  18. Effects of interface modification by H2O2 treatment on the electrical properties of n-type ZnO/p-type Si diodes

    International Nuclear Information System (INIS)

    He, Guan-Ru; Lin, Yow-Jon; Chang, Hsing-Cheng; Chen, Ya-Hui

    2012-01-01

    The fabrication and detailed electrical properties of heterojunction diodes based on n-type ZnO and p-type Si were reported. The effect of interface modification by H 2 O 2 treatment on the electrical properties of n-type ZnO/p-type Si diodes was investigated. The n-type ZnO/p-type Si diode without H 2 O 2 treatment showed a poor rectifying behavior with an ideality factor (n) of 2.5 and high leakage, indicating that the interfacial ZnSi x O y layer influenced the electronic conduction through the device. However, the n-type ZnO/p-type Si diode with H 2 O 2 treatment showed a good rectifying behavior with n of 1.3 and low leakage. This is because the thin SiO x layer acts as a thermodynamically stable buffer layer to suppress interfacial reaction between ZnO and Si. In addition, the enhanced photo-responsivity can be interpreted by the device rectifying performance and interface passivation. - Highlights: ► The electrical properties of n-ZnO/p-Si heterojunction diodes were researched. ► The n-ZnO/p-Si diode without H 2 O 2 treatment showed a poor rectifying behavior. ► The n-ZnO/H 2 O 2 -treated p-Si diode showed a good rectifying behavior. ► The enhanced responsivity can be interpreted by the device rectifying performance.

  19. Class 1 devices case studies in medical devices design

    CERN Document Server

    Ogrodnik, Peter J

    2014-01-01

    The Case Studies in Medical Devices Design series consists of practical, applied case studies relating to medical device design in industry. These titles complement Ogrodnik's Medical Device Design and will assist engineers with applying the theory in practice. The case studies presented directly relate to Class I, Class IIa, Class IIb and Class III medical devices. Designers and companies who wish to extend their knowledge in a specific discipline related to their respective class of operation will find any or all of these titles a great addition to their library. Class 1 Devices is a companion text to Medical Devices Design: Innovation from Concept to Market. The intention of this book, and its sister books in the series, is to support the concepts presented in Medical Devices Design through case studies. In the context of this book the case studies consider Class I (EU) and 510(k) exempt (FDA) . This book covers classifications, the conceptual and embodiment phase, plus design from idea to PDS. These title...

  20. Proton irradiation effects on gallium nitride-based devices

    Science.gov (United States)

    Karmarkar, Aditya P.

    Proton radiation effects on state-of-the-art gallium nitride-based devices were studied using Schottky diodes and high electron-mobility transistors. The device degradation was studied over a wide range of proton fluences. This study allowed for a correlation between proton irradiation effects between different types of devices and enhanced the understanding of the mechanisms responsible for radiation damage in GaN-based devices. Proton irradiation causes reduced carrier concentration and increased series resistance and ideality factor in Schottky diodes. 1.0-MeV protons cause greater degradation than 1.8-MeV protons because of their higher non-ionizing energy loss. The displacement damage in Schottky diodes recovers during annealing. High electron-mobility transistors exhibit extremely high radiation tolerance, continuing to perform up to a fluence of ˜1014 cm-2 of 1.8-MeV protons. Proton irradiation creates defect complexes in the thin-film structure. Decreased sheet carrier mobility due to increased carrier scattering and decreased sheet carrier density due to carrier removal by the defect centers are the primary damage mechanisms. Interface disorder at either the Schottky or the Ohmic contact plays a relatively unimportant part in overall device degradation in both Schottky diodes and high electron-mobility transistors.