  1. Monoclonal antibodies to human chorionic gonadotropin and their application to two-site sandwich radioimmunoassay

    International Nuclear Information System (INIS)

    Mizuchi, A.; Iio, M.; Miyachi, Y.

    1984-01-01

    Monoclonal antibodies were prepared against human chorionic gonadotropin (HCG). One monoclonal antibody recognized a conformational determinant expressed only on native HCG molecule and another monoclonal antibody had the specificity for the epitopes located on the β-subunit of HCG. Monoclonal antibodies reacting with different antigenic determinants on the HCG molecule were used to develop a simplified 2-site sandwich radioimmunoassay in which one monoclonal antibody was immobilized and another labeled with 125 iodine. This assay was highly specific for HCG and there was no cross-reactivity with α,β-subunit of HCG, luteinizing hormone and follicle stimulating hormone. (Auth.)

  2. Two-site sandwich radioimmunoassay of human gamma interferon with monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, E; Imai, M; Usuda, S; Tachibana, K; Okamoto, H; Ohike, Y; Nakamura, T; Miyakawa, Y; Mayumi, M [Jichi Medical School, Minamikawachi, Tochigi (Japan)

    1985-03-18

    Two monoclonal antibodies were raised against human gamma interferon (IFN-..gamma..) derived from E. coli harboring the recombinant cDNA for IFN-..gamma.., and one against a synthetic peptide representing its C-terminus amino acid sequence of 20 residues. The monoclonal antibody against the synthetic peptide reacted either with IFN-..gamma.. or the synthetic peptide. One monoclonal anti-IFN-..gamma.. did not react with the synthetic peptide, while the other showed a weak binding with the peptide. A 2-site '1-step' radioimmunoassay was developed. The assay was rapid with a sensitivity capable of detecting a few ng/ml of IFN-..gamma...

  3. Radioimmunoassays and 2-site immunoradiometric 'sandwich' assays: basic principles

    Energy Technology Data Exchange (ETDEWEB)

    Rodbard, D

    1988-10-01

    The 'sandwich' or noncompetitive reagent-excess, 2-site immunoradiometric assay (2-site IRMA), ELISA, USERIA, and related techniques, have several advantages compared with the traditional or competitive radioimmunoassays. IRMAs can provide improved sensitivity and specificity. However, IRMAs present some practical problems with nonspecific binding, increased consumption of antibody, biphasic dose response curve, (high dose hook effect), and may require special techniques for dose response curve analysis. We anticipate considerable growth in the popularity and importance of 2-site IRMA.

  4. Radioimmunoassays and 2-site immunoradiometric "sandwich" assays: basic principles.

    Science.gov (United States)

    Rodbard, D

    1988-10-01

    The "sandwich" or noncompetitive reagent-excess, 2-site immunoradiometric assay (2-site IRMA), ELISA, USERIA, and related techniques, have several advantages compared with the traditional or competitive radioimmunoassays. IRMAs can provide improved sensitivity and specificity. However, IRMAs present some practical problems with nonspecific binding, increased consumption of antibody, biphasic dose response curve, (high dose hook effect), and may require special techniques for dose response curve analysis. We anticipate considerable growth in the popularity and importance of 2-site IRMA.

  5. Kinetics of two-site immunoradiometric ('sandwich') assays

    International Nuclear Information System (INIS)

    Rodbard, D.; Feldman, Y.; Jaffe, M.L.; Miles, L.E.M.

    1978-01-01

    The mathematical model of the ideal two-site IRMA developed in the accompanying report, which assumes that both the first (solid phase) and second (labeled) antisera are 'homogeneous', fails to provide an explanation for the frequent occurrence of a paradoxical fall in the dose-response curve in the high-dose region ('high-dose hook effect'). Accordingly, the model has been extended in an attempt to provide a theoretical basis for these phenomena. Two mechanisms were considered: (A) heterogeneity of the first antiserum (which is bound to the solid phase), i.e. presence of two or more classes of sites with moderately to widely differing affinity constants; and (B) incomplete washing of the solid phase after the first reaction. This leads to an expanded system of five differential equations, five equations for conservation of mass, and fourteen rate constants. In the presence of a heterogeneous first antiserum, a high dose 'hook effect' will occur. Rapid dissociation of the ligand from the low affinity class of sites during the second 'wash' procedure will accentuate this effect. Thus, heterogeneity of binding sites is a sufficient explanation for the high-dose hook effect and is a likely mechanism in practice, since the antisera which are coupled to the solid phase have usually not been fractionated. The present studies also show that, even if dealing with homogeneous first antibody, one may still observe a high-dose hook effect if washing is incomplete after the first incubation with the antigen. Using computer simulation studies, factors affecting the magnitude of the 'high-dose hook effect' have been explored. (author)

  6. Three-site sandwich radioimmunoassay with monoclonal antibodies for a sensitive determination of human alpha-fetoprotein

    International Nuclear Information System (INIS)

    Nomura, M.; Imai, M.; Takahashi, K.; Kumakura, T.; Tachibana, K.; Aoyagi, S.; Usuda, S.; Nakamura, T.; Miyakawa, Y.; Mayumi, M.

    1983-01-01

    Utilizing monoclonal antibodies against human alpha-fetoprotein, 3 distinct antigenic determinants were identified. These antigenic determinants, provisionally designated a, b and c, were arranged in such a manner that the binding of one determinant with the corresponding antibody did not inhibit, or only barely inhibited the binding of antibodies directed to the other 2 determinants. Monoclonal antibodies with 3 different specificities were, therefore, applied to develop a sandwich-type solid-phase radioimmunoassay of the antigen in which wells were coated with anti-a, and radiolabeled anti-b together with radiolabeled anti-c was employed to detect the bound antigen. The 3-site sandwich radioimmunoassay involving 3 different determinants gave a higher sensitivity than 2-site assays in which only anti-b or anti-c was employed as a radiolabeled reagent, because the radioactivity of the 2 labeled antibodies was added on the antigen bound to immobilized anti-a. (Auth.)

  7. Immunoassay of blood spot TSH; development of a rapid two-site immunoradiometric assay and comparison with radioimmunoassay as a screening method for neonatal hypothyroidism

    International Nuclear Information System (INIS)

    Sutherland, R.M.; Ratcliffe, J.G.; Chapman, R.S.

    1982-01-01

    The development of a two-site immunoradiometric assay (IRMA) for thyrotropin (TSH) eluted from dried blood filter paper discs is described and compared with a conventional TSH radioimmunoassay (RIA) as a screening procedure for neonatal hypothyroidism. The two-site IRMA involves a primary incubation of excess labelled TSH antibody and the blood disc for 16-18 h at pH 8 and a secondary 3 h incubation under agitation, with solid phase TSH antibody. Bound and free fractions are separated by a semi-automated washing procedure. It is concluded that the two-site TSH IRMA has advantages over conventional RIA in speed, sensitivity, precision and ruggedness and can be recommended as an efficient screening procedure for neonatal hypothyroidism. (Auth.)

  8. A new solid-phase sandwich radioimmunoassay and its application to the detection of snake venom

    International Nuclear Information System (INIS)

    Coulter, A.R.; Cox, J.C.; Sutherland, S.K.; Waddel, C.J.

    1978-01-01

    A solid-phase sandwich radioimmunoassay is described which can be used for the detection and quantitative estimation of crude snake venom and a snake neurotoxin in clinical and experimental situations. Rabbit IgG antivenom or antineurotoxin, covalently coupled to a solid phase (CH-Sepharose 4B) is incubated with sample of unknown venom concentration. Venom bound by the solid-phase antibody is detected by reaction with 125 I-labelled rabbit IgG antivenom or antineurotoxin ([ 125 I]IgG). The resultant count, T, is the total (specific and non-specific) uptake of [ 125 I]IgG. Non-specific binding N, is similarly determined, but with normal rabbit IgG antivenom or antineurotoxin ([ 125 I]IgG). The resultant count, T, is the total (specific and non-specific) uptake of [ 125 I]IgG. Non-specific binding N, is similarly determined, but with normal rabbit IgG bound to the solid phase. A T:N value greater than 1.8 for human serum or urine indicates the presence of venom in a sample (P>0.95). Positive samples are assayed at several dilutions and the venom present estimated from the specific count (T-N). Levels of 0.4 ng/ml of crude tiger snake venom (TSV) and 0.1 ng/ml of neurotoxin can be reliably detected by this procedure. (Auth.)

  9. A four-step sandwich radioimmunoassay for direct selection of monoclonal antibodies to allergen molecules

    International Nuclear Information System (INIS)

    Ley, V.; Corbi, A.L.; Sanchez-Madrid, F.; Carreira, J.C.

    1985-01-01

    A 4-step radioimmunoassay has been devised for direct identification of monoclonal antibodies (MAb) directed to IgE-binding molecules. Polyvinyl chloride wells coated with purified anti-mouse kappa chain MAb (187-1) were successively incubated with: (1) MAb-containing hybridoma supernatants, (2) allergen extract, (3) allergic patients' serum pool, and (4) 125 I-labeled anti-human IgE antiserum, to detect MAb-allergen-IgE complexes. MAb to allergens from Parietaria judaica pollen and Dermatophagoides mites have been selected with this screening procedure. The affinity-purified allergen molecules competed the binding of IgE to allergen extracts coated to paper discs in a RAST inhibition assay, confirming the anti-allergen specificity of the selected MAb. This screening method is sensitive enough to allow detection of MAb directed to poorly represented allergens. (Auth.)

  10. Radioimmunoassay apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Apparatus for performing a quantitative radioimmunoassay comprising: a substantially spherical bead for carrying an antibody and a gripper for gripping said bead, said gripper comprising an integrally formed unit having a single elongate handle portion and a plurality of resilient fingers arranged at the base of the handle so that when said bead is secured within said fingers, said bead may be freely rotated about any diametric axis of the bead. In particular the invention relates to an apparatus for a two site immunoradiometric assay for serum ferritin in human blood samples. (author)

  11. Solid phase radioimmunoassays

    International Nuclear Information System (INIS)

    Wide, L.

    1977-01-01

    Solid phase coupled antibodies were introduced to facilitate the separation of bound and free labelled ligand in the competitive inhibition radioimmunoassay. Originally, the solid matrix used was in the form of small particles and since then a number of different matrices have been used such as very fine powder particles, gels, paper and plastic discs, magnetic particles and the inside surface of plastic tubes. The coupling of antibodies may be that of a covalent chemical binding, a strong physical adsorbtion, or an immunological binding to a solid phase coupled antigen. New principles of radioimmunoassay such as the solid phase sandwich techniques and the immunoradiometric assay were developped from the use of solid phase coupled antigens and antibodies. The solid phase sandwich techniques are reagent excess methods with a very wide applicability. Several of the different variants of solid phase techniques are suitable for automation. Advantages and disadvantages of solid phase radioimmunoassays when compared with those using soluble reagents are discussed. (orig.) [de

  12. Progesterone radioimmunoassay

    International Nuclear Information System (INIS)

    Allen, R.M.; Redshaw, M.R.

    1981-01-01

    This patent claims a radioimmunoassay for progesterone, which comprises contacting, in an acidic medium a sample of liquid with a predetermined amount of antibodies raised against a progesterone-protein complex, the protein being attached to the 11-position of progesterone by means of a bridging group and with a predetermined amount of a progesterone derivative having an iodinatable group attached to its 3-position by means of a bridging group, the iodinatable group being iodinated with one or more atom(s) of a radioisotope of iodine, separating the steroid bound in the resulting antibody-antigen complex from the free steroid and measuring the radioactivity of the free steroid component or of the antibody-antigen complex. Sufficient sensitivity has been achieved to enable a progesterone assay to be carried out directly on a sample of biological fluid, such as serum, plasma, urine or milk. (U.K.)

  13. Radioimmunoassay in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Ametov, A S

    1982-01-01

    A wide application of radioimmunoassay in clinical practice is shown. The main theoretical aspects of radioimmunoassay and the fields of application in clinical practice - endocrinology, oncology, allergology, cardiology, pharmacology, pediatrics, hematology, obstetrics and gynecology, are presented.

  14. Steroid radioimmunoassays

    International Nuclear Information System (INIS)

    Shinde, Y.; Hacker, R.R.; Ntunde, B.; Smith, V.G.

    1981-01-01

    An estrogen radioimmunoassay was used to study the problem of blanks in steroid assays. Negligible binding (1.5 percent) in the non-antibody tubes prevailed throughout the study. The assay was validated using accepted procedures. Both water and solvent blanks had estrogen concentrations of 7-9 pg/tube. However, neither water nor solvent blanks showed a dose-related response, indicating that they were 'real' blanks. Exogenous estradiol, when added to water and solvent in quantities less than the estimated blank, was not quantitatively recovered. However, exogenous estradiol added to the water solvent in quantities greater than the blank estimate was quantitatively recovered. The sensitivity of the reference standard curve was 6-10 pg/tube, approximately the same as the blank estimate. These results indicated that the estimates of water and solvent blanks were measures of the assay sensitivity. In such circumstances, it is suggested that blank estimates should not be subtracted from sample values. If the blank estimates are high, attention should be directed towards improving the sensitivity of the assay

  15. Trypsin radioimmunoassay

    International Nuclear Information System (INIS)

    Scheithauer, R.; Wolf, F.; Tympner, F.

    1981-01-01

    In 29 patients with suspicion of pancreatic disease standard secretin-pancreozymin-test was performed parallel to trypsin determination by radioimmunoassay before and after stimulation with secretin. Mean serum trypsin in normal subjects was 175 ng BIT/ml (range 90-250), the maximum after stimulation being 20 minutes after secreting injection (range 110-550). Preliminary normal values are 270 ng BIT/ml for basal concentration and 650 ng BIT/ml for 20 min after secretin stimulation. In the group of normals there was no case of misinterpretation. In patients with several pathological parameters (n = 10) basal trypsin concentration was increased in 7 cases, the stimulated value was concordant with the definite diagnosis in every case. Significant advantage for diagnostics was derived in patients having had pancreatic diseases before, however being actually normal with respect to standard diagnostic parameters. All these patients revealed increased trypsin concentrations after stimulation and 50% of them showed increased basal values. Equivocal results were seen in patients with endstage pancreatitis as well as in case of obstruction during reduced secretion. (orig.) [de

  16. Handbook of radioimmunoassay

    International Nuclear Information System (INIS)

    Abraham, G.E.

    1977-01-01

    This handbook provides clear, detailed descriptions of ways to set up radioimmunoassay procedures for a variety of polypeptides and low molecular weight compounds. It covers extensively the subjects of statistical evaluation of radioimmunoassay, instrumentation in radioimmunoassay, and radiation safety in the performance of radioimmunoassay. Related nonconventional methods are also discussed. Contributors to this handbook have presented their own procedures for performing the radioimmunoassay and their rationale for choosing particular reagents and conditions. Emphasis is on providing sufficient information to enable relatively inexperienced immunoassayists to set up assay systems with a minimum of difficulty

  17. Carcinoembryonic antigen radioimmunoassay in hepatic tumor

    International Nuclear Information System (INIS)

    Aburano, Tamio; Tonami, Norihisa; Hisada, Kinichi

    1976-01-01

    Carcinoembryonic antigen (CEA) radioimmunoassay with the sandwich method was performed in addition to both α 1 -fetoprotein (AFP) radioimmunoassay and liver scintigraphy to elevate the diagnostic accuracy of hepatic tumor in nuclear medicine. All of the ten healthy controls and 47 of 52 cases with benign disease showed a CEA titer less than 2.5ng/ml. 78 of 188 cases (41%) of malignant disease showed a titer of over 2.5ng/ml; however most positive cases were metastatic, especially to the liver. In metastatic liver cancer, thirtythree out of 46 cases (72%) showed a strongly positive CEA titer. Over 5ng/ml was taken as the lower limit for predicting metastasis to the liver. On the other hand, in primary liver cancer thirty-two out of 35 cases (91%) showed a strongly positive AFP titer over 200ng/ml, although only one case showed a CEA titer over 5ng/ml. Seven cases (15%) of metastatic liver cancer also showed a strongly positive AFP titer; however six of these positive cases showed a CEA titer over 5ng/ml. In metastatic liver cancer, eleven out of 46 cases (24%) showed no clearcut focal defects on liver scintigram. Nine of these negative cases showed a CEA titer over 5ng/ml, and at subsequent operation metastatic liver lesions were found. The overall diagnostic accuracy for detecting metastatic liver cancer with a combination of both methods was 95%. CEA radioimmunoassay was found to be useful for the elucidation of the nature of focal hepatic lesions in addition to AFP radioimmunoassay, and moreover could be used as an adjunct to liver scintigraphy for the detection of metastatic lesions in the liver. (auth.)

  18. SIGNS The sandwich sign

    African Journals Online (AJOL)

    The sandwich sign is demonstrated on cross-sectional imaging, commonly on CT or ultrasound. It refers to homogeneous soft- tissue masses representing mesenteric lymphadenopathy as the two halves of a sandwich bun, encasing the mesenteric fat and tubular mesenteric vessels that constitute the 'sandwich filling' (Figs ...

  19. Radioimmunoassay for tetrahydrocortisol

    International Nuclear Information System (INIS)

    Mougey, E.H.

    1978-01-01

    A radioimmunoassay for urinary tetrahydrocortisol (THF) is described. Antibodies were produced in rabbits against a THF-monohemisuccinate:bovine serum albumin conjugate. The radioimmunoassay procedure involves enzymic hydrolysis of the urine, extraction with ethyl acetate, radioimmunoassay, and separation of free from bound steroid with Somogyi reagents. The antibody showed some cross-reaction with tetrahydro substance S (36%) which does not occur in urine in appreciable amounts and with tetrahydrocortisone (10%) which does. An analysis of monkey urine extracts before and after tlc purification revealed that the THF antibody was specific enough to permit assay of urines for THF during stress experiments without a purification step. THF values obtained correlated very highly with 17-hydroxycorticosteroid values on the same urines obtained from monkeys during a chair restraint experience (r = 0.97). Also for comparison pruposes these same urines were assayed for free THF, total cortisol, and free cortisol. The free (unconjugated) steroids showed the greatest percentage increase over basal levels

  20. Radioimmunoassay for biopterin

    International Nuclear Information System (INIS)

    Nagatsu, Toshiharu; Yamaguchi, Tokio; Kato, Takeshi; Sugimoto, Takashi; Matsuura, Sadao.

    1979-01-01

    Specific antibodies against biopterin, neopterin, and 6,7-dimethylpterin were prepared and a new type of radioimmunoassay, to which these pterins were subjected was developed. This new type of radioimmunoassay was used to determine biopterin in human urine. Specific antiserum against biopterin did not crossreact significantly with tetrahydro-biopterin, dihydro-biopterin, neopterin, 6,7-dimethylpterin, pterin, or folic acid and showed 30% binding of biopterinyl-caproyl- ( 125 I ) tyramide at a dilution of 1:800. The antisera against neopterin and dimethylpterin also showed a high specificity and did not cross-react significantly with the other pterins. The sensitivity of the radioimmunoassay was increased about ten-fold by pre-incubating the antiserum with 6,7-dimethylpterinyl-caproyl to remove antibodies against the caproic acid moiety of the biopterin conjugate. The recovery of biopterin or tetrahydro-biopterin added human urine was nearly 100% according to this type of radioimmunoassay, and the biopterin concentrations in the urine that were obtained by means of this type of radioimmunoassay showed a fairly good agreement with the values obtained by means of bioassay. The biopterin contents per milliliter of human urine showed considerable variations depending on the subjects, but those per milligram of creatinine were found to be fairly constant in normal subjects. Therefore, biopterin concentrations per milligram of creatinine in human urine may be a good indicator of biopterin metabolism in clinical chemistry. This new type of radioimmunoassay is simple, highly specific, and reproducible. Therefore, it may be very useful for the screening of atypical phenylketonuria due to biopterin deficiency and also for the study of the pathogenesis of various biopterin metabolic diseases. (J.P.N.)

  1. Radioimmunoassay for biopterin

    Energy Technology Data Exchange (ETDEWEB)

    Nagatsu, T; Yamaguchi, T; Kato, T [Tokyo Inst. of Tech. (Japan); Sugimoto, T; Matsuura, S

    1979-06-01

    Specific antibodies against biopterin, neopterin, and 6,7-dimethylpterin were prepared and a new type of radioimmunoassay, to which these pterins were subjected was developed. This new type of radioimmunoassay was used to determine biopterin in human urine. Specific antiserum against biopterin did not crossreact significantly with tetrahydro-biopterin, dihydro-biopterin, neopterin, 6,7-dimethylpterin, pterin, or folic acid and showed 30% binding of biopterinyl-caproyl- ( /sup 125/I ) tyramide at a dilution of 1:800. The antisera against neopterin and dimethylpterin also showed a high specificity and did not cross-react significantly with the other pterins. The sensitivity of the radioimmunoassay was increased about ten-fold by pre-incubating the antiserum with 6,7-dimethylpterinyl-caproyl to remove antibodies against the caproic acid moiety of the biopterin conjugate. The recovery of biopterin or tetrahydro-biopterin added human urine was nearly 100% according to this type of radioimmunoassay, and the biopterin concentrations in the urine that were obtained by means of this type of radioimmunoassay showed a fairly good agreement with the values obtained by means of bioassay. The biopterin contents per milliliter of human urine showed considerable variations depending on the subjects, but those per milligram of creatinine were found to be fairly constant in normal subjects. Therefore, biopterin concentrations per milligram of creatinine in human urine may be a good indicator of biopterin metabolism in clinical chemistry. This new type of radioimmunoassay is simple, highly specific, and reproducible. Therefore, it may be very useful for the screening of atypical phenylketonuria due to biopterin deficiency and also for the study of the pathogenesis of various biopterin metabolic diseases.

  2. Radioimmunoassay of pancreatic glucagon

    International Nuclear Information System (INIS)

    Nooijen, W.J.

    1979-01-01

    The author presents some of the problems and concepts related to the development of a radioimmunoassay of pancreatic glucagon. A specific derivatization of glucagon for raising specific anti-glucagon antisera is introduced, and special procedures for diminishing the non-specific effect are outlined. (G.T.H.)

  3. Erythropoietin radioimmunoassay studies

    International Nuclear Information System (INIS)

    Garcia, J.F.

    1982-01-01

    A highly sensitive radioimmunoassay capable of measuring erythropoietin concentrations in very small amounts of serum as been developed. After establishing normal human values on a large series of serum samples, serum samples from patients with polycythemia vera and patients with secondary polycythemia were obtained and the erythropoietin concentrations measured

  4. Two-site sandwich immunoradiometric assay of human lymphotoxin with monoclonal antibodies and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Meager, A; Parti, S; Leung, H; Woolley, J; Peil, E; Sidhu, S; Roberts, T

    1987-11-23

    Three monoclonal antibodies (MoAbs L49-15, L81-11 and L238-14) were raised against recombinant human lymphotoxin (rLT) derived from E. coli containing the cDNA sequence specifying LT. These MoAbs were ideal reagents for immunoassay of LT and a very sensitive, highly specific immunoradiometric assay (IRMA) was developed. This assay was rapid to perform and was capable of detecting as little as 10 pg/ml of LT. Application of the LT IRMA in combination with previously developed human gamma-interferon (IFN-..gamma..) and human tumour necrosis factor (TNF)-specific IRMA permitted independent estimations of these three substances to be carried out in parallel. By these means, it was found that RPMI 1788 lymphoblastoid cell line produced both LT and TNF, but not IFN-..gamma... Extensive analyses on cytokine (monokine and lymphokine) preparations derived from a variety of activated lymphocytes are also reported. Co-production of LT, TNF, and IFN-..gamma.. was a common finding, even occurring in alloantigen-specific T helper cell clones. 45 refs.; 3 figs.; 4 tabs.

  5. Evaluation of radioimmunoassay of anti-thyroglobulin antibodies

    International Nuclear Information System (INIS)

    Lourme, J.; Dessaint, J.P.; Capron, A.

    1985-01-01

    A statistical analysis is performed on the results of 881 determinations of thyroglobulin antibodies in humans. Antibodies were assayed comparatively by radioimmunoassay using a sandwich method and by tanned red cell haemagglutination. A very good concordance was found between the two techniques, apart from the low titer zone. A significant correlation was observed between on the one side, the radioactivity index of the diluted serum, defined as the increment of radioactivity bound by undiluted patient serum over the positive threshold, divided by this threshold, and, on the other side, the antibody titer, i.e. the reciprocal of the highest serum dilution superior to the positive threshold by radioimmunoassay. The corresponding linear regression allows to define a arbitrary unit system which associates values of the radioactivity index with an average antibody titer [fr

  6. Radioimmunoassay in endocpinology

    International Nuclear Information System (INIS)

    Ametov, A.S.; Torjtsina, L.K.

    1983-01-01

    Radioimmunoassay of the level of various hormones in blood for the diagnosis of thyroid gland diseases, diabetes mellitus, pancreatic gland diseases, adrenal cortex, phophorous-calcium exchange, cerebral-hypophysial deseases, peripheric endocrine glands diseases and others are considered. It is shown that CEA methods implantation in clinical practice permits to obtain a number of new data on mechanism of neurohumoral interrelations of various organs and organism systems

  7. Automation systems for radioimmunoassay

    International Nuclear Information System (INIS)

    Yamasaki, Paul

    1974-01-01

    The application of automation systems for radioimmunoassay (RIA) was discussed. Automated systems could be useful in the second step, of the four basic processes in the course of RIA, i.e., preparation of sample for reaction. There were two types of instrumentation, a semi-automatic pipete, and a fully automated pipete station, both providing for fast and accurate dispensing of the reagent or for the diluting of sample with reagent. Illustrations of the instruments were shown. (Mukohata, S.)

  8. Comparative study of radioimmunoassay dates

    International Nuclear Information System (INIS)

    Venegas Sanchez, Ruth.

    1986-01-01

    The radioimmunoassay is frequently used in clinical chemistry for the concentration determination of several substances like hormones as thyrotropine and thyroxine. In this experiment the dates of tyroxine radioimmunoassay are processed by three methods: a) like the recommendation of the IAEA, b) Dr. G. Chase method, c) according to the provider. The best method was Dr. Chase's. (author)

  9. Automation of radioimmunoassay

    International Nuclear Information System (INIS)

    Yamaguchi, Chisato; Yamada, Hideo; Iio, Masahiro

    1974-01-01

    Automation systems for measuring Australian antigen by radioimmunoassay under development were discussed. Samples were processed as follows: blood serum being dispensed by automated sampler to the test tube, and then incubated under controlled time and temperature; first counting being omitted; labelled antibody being dispensed to the serum after washing; samples being incubated and then centrifuged; radioactivities in the precipitate being counted by auto-well counter; measurements being tabulated by automated typewriter. Not only well-type counter but also position counter was studied. (Kanao, N.)

  10. Radioimmunoassay in microtiter plates

    International Nuclear Information System (INIS)

    Hirschberg, T.; Hirschberg, H.

    1987-01-01

    A radioimmunoassay was performed in the wells of casein-coated microplates employing 125 I-labelled sheep anti-human second antibody. The antigen-antibody complexes were thereafter dislodged from the well walls using detergent sodium dodecyl sulfate (SDS) and the entire contents of the wells were simultaneously absorbed into 48 cellulose acetate-absorbing cartridges. All 48 cartridges were transferred to counting vials and the radioactivity determined by standard gamma counting techniques. The particular advantage of the method described here is the ease with which the supernatants can be collected and transferred to counting vials with minimal handling of radioactive samples. 6 refs.; 1 figure; 1 table

  11. Radioimmunoassay of plasma progesterone

    Energy Technology Data Exchange (ETDEWEB)

    Langer, L; Veleminsky, J [Institute of Clinical Endocrinology, Lubochna (Czechoslovakia); Hampl, R; Starka, L [Vyzkumny Ustav Endokrinologicky, Prague (Czechoslovakia); Holan, J [Comenius Univ., School of Medicine, Martin (Czechoslovakia). Dept. of Physics and Nuclear Medicine

    1978-06-30

    A simple modification of plasma progesterone radioimmunoassay is described. 11..cap alpha..-Hydroxyprogesterone hemisuccinate - BSA conjugate was used as an immunogen. (1,2,6,7-H-3) Progesterone specific radioactivity 82 Ci.mmol/sup -1/ was purchased from Radiochemical Centre Amersham (England). The method has been applied for the analysis of more than 2000 plasma samples. The typical fluctuation of progesterone in plasma during the menstrual cycle, using data obtained with this method is illustrated. The reliability criteria of the method are given.

  12. Radioimmunoassay for Melatonin

    International Nuclear Information System (INIS)

    Tapp, E.; Skinner, R.G.; Phillips, V.

    1980-01-01

    A radioimmunoassay for melatonin has been developed and used to measure the level of melatonin of male and post-menopausal female patients coming to operation for benign and malignant conditions. The amount of melatonin in the serum of the females was considerably lower than that in males. No difference could be found between patients suffering from benign and malignant conditions. A patient with a non-parenchymatous pineal tumour had considerably lower levels in the serum at three months after surgery and radiotherapy. A further month later melatonin could not be found in samples of serum taken over a 24-hour period. (author)

  13. Radioimmunoassay of steroid hormone

    International Nuclear Information System (INIS)

    Murakami, Tadashi

    1975-01-01

    Low acid pepsin treated gamma-globulin was applied to ammonium sulfate salting out method, which was a method to separate bound fraction from free one in radioimmunoassay of steroid hormone, and the effect of the separation and the standard curve were examined. Pepsin treated gamma-globulin was prepared in pH 1.5 to 5.5 and then the pepsin was completely removed. It had an effect to accelerate the precipitation in radioimmunoassay of steroid hormone labelled with 3 H. The effect of pepsin treated gamma-globulin to adhere free steroid hormone and to slat out bound one was compared with that of human gamma-globulin. Pepsin treated gamma-globulin, which was water soluble, could easier reach its optimal concentration, and the separation effect was better than human gamma-globulin. The standard curve of it was steeper, particularly in a small dose, and the reproducibility was also better. It could be applied not only to aldosterone and DOC, but also to the steroid hormones, such as progesterone and DHEA, and it seemed suitable for routine measurement method. (Kanao, N.)

  14. Radioimmunoassay of oxytocin

    International Nuclear Information System (INIS)

    Dawood, M.Y.; Raghavan, K.S.; Pociask, C.

    1978-01-01

    The evaluation of a radioimmunoassay of oxytocin is described. The method involved careful collection and transportation of blood at 4 0 C, acidification of the plasma, extraction with Fuller's earth and radioimmunoassay using antisera raised in rabbits immunized against oxytocin conjugated to bovine serum albumin and 125 I-labelled oxytocin. The antisera showed insignificant cross-reaction with a variety of small peptides including vasopressin and vasotocin. The limit of detection of the assay was 2.5 pg with intra-assay and interassay coefficients of variation of 7 to 15% and 12 to 18% respectively. Seventy-seven per cent (88 out of 116) of the pregnant women tested had detect-able maternal plasma oxytocin. Serial samples of maternal plasma showed a significant increase in oxytocin from the first to the second stage of labour and a significant decrease in the third stage. Oxytocin concentrations in the umbilical arterial plasma were significantly higher in patients in labour. The significance of these findings is discussed. (author)

  15. Radioimmunoassay of platelet proteins

    International Nuclear Information System (INIS)

    Pepper, D.S.

    1987-01-01

    The radioimmunoassay of platelet-specific proteins has proven to be an excellent way of monitoring platelet activation in vivo. In contrast to earlier methods such as aggregometry, which has been the major tool used in the evaluation of antiplatelet drugs, the RIAs are capable of working with samples which have been subjected to physiological conditions such as haematocrit, oxygen tension, shear rate and ionized calcium concentration. Also, in contrast to aggregometry, no choice of agonist is necessary. Thus, for the first time it has been possible to monitor the effects of therapeutic intervention with drugs upon the platelet release reaction in vivo. It seems reasonable to equate the release reaction in vivo with activation in vivo, though the stimuli necessarily remain unknown. Nevertheless, the fact that a significant number of the compounds mentioned in Table 3 are indeed capable of reducing platelet activation in vivo and that this effect can be measured objectively is a major step forward in our understanding of platelet pharmacology. Two important goals remain to be achieved, however, the establishment of nonhuman animal models for the evaluation of newer compounds in vivo and longer-term goal of proving in the clinical setting the relevance or otherwise of platelet activation per se to the clinical outcome of a particular disease. In this respect, the availability of accurate, reliable and specific radioimmunoassays has a central role

  16. Predicting safe sandwich production

    DEFF Research Database (Denmark)

    Birk, Tina; Duan, Zhi; Møller, Cleide Oliveira de Almeida

    2014-01-01

    Time and temperature control is crucial to avoid growth of pathogens during production and serving of cold ready-to-eat meals. The Danish guidelines state that chilled foods, such as sandwiches, should not be outside the cold chain for more than 3 hours including the time for preparation...... and serving. However, Danish sandwich producing companies find it challenging to comply with this and have expressed a need for more flexibility. The Danish guidelines do allow for a prolongation of the acceptable time outside the cold chain, if the safety of the specific production can be documented...

  17. Radioimmunoassay of anabolic steroids

    International Nuclear Information System (INIS)

    Hampl, R.; Stranska, I.; Starka, L.; Picha, J.; Chundela, B.

    1978-01-01

    Alternative antisera against 17 α-methyltestosterone and 19-nortestosterone were raised and used for radioimmunoassay of anabolic steroids. Tritiated compounds were used as radioligands. The RIA method suitable for doping control is proposed for 17 α-alkylated anabolic steroids in both plasma and urine, using qoat antiserum against methyltestosterone-3-carboxymethyloxime-BSA. Sensitivity of the method was expressed as least amount of nonradioactive methandienone which, when added to normal urine or plasma, caused statistically significant decrease of measured supernatant radioactivity at 99% level. The amounts from 50 to 500 pg were tested, each in eight parallel determinations. The amounts of 100 pg for plasma and 200 pg for urine met these criteria. The respective coefficients of variation did not depend on the amount of steroid added in this range. They averaged 4.60% for plasma and 4.95% for urine, respectively. (T.I.)

  18. Radioimmunoassay for jasmonic acid

    Energy Technology Data Exchange (ETDEWEB)

    Knoefel, H.D.; Brueckner, C.; Kramell, R.; Sembdner, G.; Schreiber, K. (Akademie der Wissenschaften der DDR, Halle/Saale. Inst. fuer Biochemie der Pflanzen)

    1984-01-01

    A radioimmunoassay (RIA) for the natural plant growth regulator jasmonic acid (JA) was developed. The antiserum was raised in rabbits against (+-)-JA linked to bovine serum albumin. As tracer tritium labelled (+-)-JA (spec. act. 7.4 x 10/sup 9/ Bq x mmol/sup -1/) was used. Cross-reactivity studies with compounds structurally related to JA demonstrated the antiserum to be specific for JA, abscisic acid normally present in the same extract does not interfer. The RIA has a detection limit of 2 ng (-)-JA methylester, a measuring range 2-200 ng, and no extensive purification is required prior to estimation. Therefore, in JA analysis the RIA described is superior to GC, HPLC, and bioassay. This new method has been employed for studies on the distribution of JA in different plant organs of the broad bean, Vicia faba L.

  19. Radioimmunoassay of synthetic steroids

    Energy Technology Data Exchange (ETDEWEB)

    Raynaud, J -P; Bucourt, R; Salmon, J

    1975-12-01

    The sensitivity of a radioimmunoassay depends on the intrinsic association constant of the interaction between ligand and antibody. Its specificity depends on the position of the chain which forms the link with the antigen. Thus, an antibody specific of estradiol has been obtained by coupling estradiol to albumin via a chain at position 7. For synthetic steroids the structure of which is sufficiency different from that of natural hormones, the requirements for a sensitive assay method not involving chromatography are simply maximum affinity and positioning of the couple at a site which does not undergo metabolic attack. These criteria were used to develop assays for R 2858 and R 2453 which obviate the need to administer radioactive product in clinical pharmacology. Cross-reaction with structural analogs may be used to assay competitors. Thus, R 2323 antibody, highly specific for endogenous steroids, may be used to assay other trienes such as R 1697 (trenbolone) and R 2010 (norgestrienone).

  20. Delta antibody radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Kselikova, M; Urbankova, J

    1985-11-15

    The principle and procedure are described of the radioimmunoassay of delta antibody (delta-Ab) using the ABBOTT ANTI-DELTA kit by Abbott Co. A description is given of the kit, the working procedure and the method of evaluation. The results are reported of the incidence of delta-Ab in sera of patients with viral hepatitis B, in haemophiliacs, carriers of the hepatitis B virus surface antigen (HBsAg) and blood donors. The presence was detected of delta-Ab in one HBsAg carrier. The necessity is emphasized of delta-Ab determinations in the blood of donors in view of the antibody transfer with blood and blood preparations.

  1. Radioimmunoassay of erythropoietin

    Energy Technology Data Exchange (ETDEWEB)

    Goldwasser, E; Sherwood, J B [Chicago Univ., IL (USA). Dept. of Biochemistry

    1981-07-01

    A brief review of the historical development of the radioimmunoassay (RIA) for serum erythropoietin is given. It has been shown that there is reasonable agreement between the results obtained by RIA and those obtained by the previously used bioassay. By RIA, a mean normal serum titre of 18 mu/ml erythropoietin has been determined in a study of 445 individuals. Serum erythropoietin results for patients with polycythaemia vera have not been shown to be significantly different from normal values but in patients with secondary polycythaemia, serum titres averaging 94 mu/ml have been found. The predicted physiological changes in erythropoietin titre have also been demonstrated in humans using the RIA; increasing after bleeding and decreasing after red cell administration. Studies of erythropoietin levels in experimental animals have shown that, with the particular antiserum used, the sensitivity of the RIA is markedly reduced.

  2. A radioimmunoassay for chicken avidin

    International Nuclear Information System (INIS)

    Kulomaa, M.S.; Elo, H.A.; Tuohimaa, P.J.

    1978-01-01

    A double-antibody solid-phase radioimmunoassay for chicken avidin is reported. Avidin was labelled with 125 I by the chloramine-T method. The bound and free avidin were separated with a second antibody bound to a solid matrix. In the logit-log scale the standard curve was linear from 1-2 to 100-200ng of avidin/ml. Cross-reaction of ovalbumin was less than 0.015%. Saturation of biotin-binding sites of avidin with an excess of biotin decreased radioimmunoassay values by about 15%. Recovery studies indicated that avidin can be assayed from all chicken tissues studied with radioimmunoassay, whereas the [ 14 C]biotin/bentonite method gave poor recoveries for avidin in the liver and kidney. Radioimmunoassay and the [ 14 C]biotin/bentonite method gave similar concentrations for oviduct avidin. (author)

  3. Clinical indications of prolactin radioimmunoassay

    International Nuclear Information System (INIS)

    Lengyel, A.M.J.; Vieira, J.G.H.; Zanella, M.R.; Zampieri, M.; Chacra, A.R.

    1980-01-01

    Is a review is presented of the main clinical uses of prolactin measurements, including the galactorrhea-amenorrhea syndrome, an experiment employing the prolactin radioimmunoassay is related. (Author) [pt

  4. Automatic computation of radioimmunoassay data

    International Nuclear Information System (INIS)

    Toyota, Takayoshi; Kudo, Mikihiko; Abe, Kanji; Kawamata, Fumiaki; Uehata, Shigeru.

    1975-01-01

    Radioimmunoassay provided dose response curves which showed linearity by the use of logistic transformation (Rodbard). This transformation which was applicable to radioimmunoassay should be useful for the computer processing of insulin and C-peptide assay. In the present studies, standard curves were analysed by testing the fit of analytic functions to radioimmunoassay of insulin and C-peptides. A program for use in combination with the double antibody technique was made by Dr. Kawamata. This approach was evidenced to be useful in order to allow automatic computation of data derived from the double antibody assays of insulin and C-peptides. Automatic corrected calculations of radioimmunoassay data of insulin was found to be satisfactory. (auth.)

  5. Salads, Sandwiches and Desserts.

    Science.gov (United States)

    Marine Corps Inst., Washington, DC.

    Developed as part of the Marine Corps Institute (MCI) correspondence training program, this course on salads, sandwiches, and desserts is designed to provide Marine food service personnel with a general background in the proper techniques for the preparation of these items. Introductory materials include specific information for MCI students and a…

  6. Radioimmunoassay of polypeptide hormones and enzymes

    International Nuclear Information System (INIS)

    Felber, J.P.

    1974-01-01

    General principles of radioimmunoassay are reviewed. Detailed procedures are reviewed for the following hormones: insulin, pituitary hormones, gonadotropins, parathyroid hormone, ACTH, glucagon, gastrin, and peptide hormones. Radioimmunoassay of enzymes is also discussed. (U.S.)

  7. Radioimmunoassay for human ACTH

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, S; Oyama, H; Tenku, A; Horino, M [Kawasaki Medicial School, Kurashiki, Okayama (Japan); Kobayashi, K

    1977-03-01

    A radioimmunoassay method for human adrenocorticotropic hormone (ACTH) is described. The antiserum was produced in a guinea pig by multiple injections of a total of 1 mg of porcine ACTH adsorbed with CM-cellulose and mixed with complete Freund's adjuvant. The antiserum used for this study at a final dilution of 1:500,000 was obtained from a guinea pig after 10 immunizations. A highly purified native ACTH (Li, ..cap alpha.. sub(h)sup(1-39) ACTH) was used as an assay standard and a tracer hormone. Separation of free and bound hormone was achieved by dextran coated charcoal. Extraction of ACTH from plasma samples was performed by Donald's method modified with silicic acid. The antibody appeared to be directed against the C-terminal portion of the hormone molecule and showed no significant reaction with other pituitary hormones (GH, TSH, LH, FSH, Hpr, Oxytocin, Arginine-and Lysine-Vasopressin). Plasma ACTH levels of 5 healthy subjects at nine o'clock averaged 32 +- 8.5 pg/ml (M +- SD). Plasma ACTH concentrations in a case of Sheehan's syndrome and of an untreated adrenogenital syndrome at nine o'clock were less than 20 and 194 pg/ml, respectively. A case of Cushing's syndrome accompanied with bilateral nodular hyperplasia of the adrenal cortex showed diminished diurnal variation and normal levels of plasma ACTH. In contrast, elevated plasma ACTH levels and lack of diurnal rhythm of ACTH secretion were observed in a suspected case of Cushing's disease.

  8. Radioimmunoassay for urinary albumin

    International Nuclear Information System (INIS)

    Woo, J.; Floyd, M.; Cannon, D.C.; Kahan, B.

    1978-01-01

    We describe a rapid, sensitive, and precise radioimmunoassay for urinary albumin (U/sub alb/). Aliquots of diluted urine were incubated at room temperature for 1 h with 125 I-labelled albumin and a rabbit antiserum monospecifid for human albumin. Phase separation was effected by the double-antibody technique. The dose-response curve was linear in the range of 15.6 to 10,000 ng, equivalent to 4 to 3000 mg/liter of urine. The limit of sensitivity was 16 ng of albumin. The coefficient of assay variation was 4.8%, both at 44 mg/liter and at 1304 mg/liter. A displacement curve obtained with a serially diluted urine sample of high albumin concentration was completely superimposable with the curve for which human albumin was used as a standard. In 26 normal individuals the range for U/sub alb/ was 2.2 to 12.6 mg/24 h, and for albumin clearance (C/sub alb/), 1.8 x 10 -5 --19.6 x 10 -5 ml/min. After renal homografts in 25 patients, U/sub alb/ ranged from 16.9 to 9928 mg/24 h, and C/sub alb/ from 2.7 x 10 -4 to 1.7 x 10 -1 ml/min. Both increased U/sub alb/ and C/sub alb/ correlated well with the severity of renal homograft rejection

  9. Radioimmunoassay for a human prostate specific antigen

    International Nuclear Information System (INIS)

    Machida, T.; Miki, M.; Ohishi, Y.; Kido, A.; Morikawa, J.; Ogawa, Y.

    1983-01-01

    As a marker for prostatic cancer, a prostate-specific antigen was purified from human prostatic tissues. Double antibody radioimmunoassay utilizing immune reaction was developed on the basis of the purified prostatic antigen (PA). Measurement results have revealed that PA radioimmunoassay is much better than prostatic acid phosphatase (PAP) radioimmunoassay in the diagnosis of prostatic cancer

  10. Radioimmunoassay for human myoglobin

    International Nuclear Information System (INIS)

    Kondo, Akira

    1981-01-01

    1 A new radioimmunoassay (RIA) for human myoglobin (Mb) using two antibody technique was developed as a microassay of Mb. This RIA is characterized as follows; 1) Radioiodination of human Mb was successfully done for the first time by chloramine T method, which yielded Iabelled Mb with high specific activities ranging 40 - 60 μCi/μg. 2) Affinity chromatography was used to obtain purified anti-human Mb antibody, which improved the sensitivity of the RIA remarkably, and excluded the effects of serum and urine. 2 The sensitivity of the RIA was 1 ng/ml in sera and 2 ng/ml in urine. The average recovery was 92.7%. Both intra-assay and inter-assay coefficients of variation were below 10%. 3 With this method, Mb purified from skeletal and cardiac muscles was shown to have same immunological nature. 4 Serum concentrations of Mb in normal adults were 13.1 +- 6.1 ng/ml (mean +- S.D.) with a range of 1 - 28 ng/ml. No sex difference was observed. Urinary Mb Ievels in normal adults were less than 4 ng/ml and 24-hour urinary excretions were less than 6 μg. With this method, serum and urinary Mb concentrations were determined in patients with various disorders such as myopathies and myocardial disorders and with anesthesia. Serum Mb concentrations were revealed to be elevated to 50000 ng/ml in malignant hyperthermia, 4000 ng/ml in acute myocardial infarction, 1000 ng/ml in Duchenne muscular dystrophy and 4000 ng/ml in polymyositis. Urinary Mb level was elevated when serum Mb rose to 2000 - 3000 ng/ml. 5 In order to apply RIA of Mb in daily clinical practices, time needed for the assay was shortened by separation of free and antibody-bound Mb by the polyethylene glycol method immediately after incubation was performed at 37 0 C for 2 hours. (author)

  11. Radioimmunoassay for human myoglobin

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, A. (Tokushima Univ. (Japan). School of Medicine)

    1981-04-01

    1 A new radioimmunoassay (RIA) for human myoglobin (Mb) using two antibody technique was developed as a microassay of Mb. This RIA is characterized as follows; 1) Radioiodination of human Mb was successfully done for the first time by chloramine T method, which yielded Iabelled Mb with high specific activities ranging 40 - 60 ..mu..Ci/..mu..g. 2) Affinity chromatography was used to obtain purified anti-human Mb antibody, which improved the sensitivity of the RIA remarkably, and excluded the effects of serum and urine. 2 The sensitivity of the RIA was 1 ng/ml in sera and 2 ng/ml in urine. The average recovery was 92.7%. Both intra-assay and inter-assay coefficients of variation were below 10%. 3 With this method, Mb purified from skeletal and cardiac muscles was shown to have same immunological nature. 4 Serum concentrations of Mb in normal adults were 13.1 +- 6.1 ng/ml (mean +- S.D.) with a range of 1 - 28 ng/ml. No sex difference was observed. Urinary Mb Ievels in normal adults were less than 4 ng/ml and 24-hour urinary excretions were less than 6 ..mu..g. With this method, serum and urinary Mb concentrations were determined in patients with various disorders such as myopathies and myocardial disorders and with anesthesia. Serum Mb concentrations were revealed to be elevated to 50000 ng/ml in malignant hyperthermia, 4000 ng/ml in acute myocardial infarction, 1000 ng/ml in Duchenne muscular dystrophy and 4000 ng/ml in polymyositis. Urinary Mb level was elevated when serum Mb rose to 2000 - 3000 ng/ml. 5 In order to apply RIA of Mb in daily clinical practices, time needed for the assay was shortened by separation of free and antibody-bound Mb by the polyethylene glycol method immediately after incubation was performed at 37/sup 0/C for 2 hours.

  12. Radioimmunoassay for pyridostigmine

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, H.G.; Lukey, B.J.; Gepp, R.T.; Corpuz, R.P.; Lieske, C.N.

    1988-01-01

    Pyridostigmine is a cholinergic drug used for the treatment of myasthenia gravis and for antagonizing the effects of non-depolarizing muscle relaxants. In addition, military organizations in several countries have an active interest in pyridostigmine as a pretreatment compound for nerve agent poisoning. Anti-pyridostigmine antibodies were produced in rabbits using a pyridostigmine analog conjugated to keyhole limpet hemocyanin. These antibodies were used for development of a radioimmunoassay that has a linear standard curve (r2=0.986) ranging from 0.5 to 10.0 ng/ml of pyridostigmine bromide in a 0.1-ml plasma sample. This assay measures pyridostigmine in plasma with better sensitivity and much greater through-put than do current state-of-the-art high-performance liquid chromatography techniques. In addition, only small volumes (100ml) of the plasma samples are required. Plasma levels of pyridostigmine were determined in the rat after intramuscular administration (0.056mg/kg) of pyridostigmine bromide. Estimates of the various pharmacokinetic parameters were calculated using the computer program NONLIN84. The results were as follows: apparent volume of distribution = 1.97 1/kg, absorption rate constant = 0.277 min-1, elimination rate constant = 0.0273 min-1, area under the curve = 1010 ng x min/ml, absorption rate half-life = 2.41 min, elimination rate half-life = 24.8 min, maximal plasma concentration (Cmax) = 21.3 ng/ml and time to Cmax = 9.02 min.

  13. Peptide radioimmunoassays in clinical medicine

    International Nuclear Information System (INIS)

    Geokas, M.C.; Yalow, R.S.; Straus, E.W.; Gold, E.M.

    1982-01-01

    The radioimmunoassay technique, first developed for the determination of hormones, has been applied to many substances of biologic interest by clinical and research laboratories around the world. It has had an enormous effect in medicine and biology as a diagnostic tool, a guide to therapy, and a probe for the fine structure of biologic systems. For instance, the assays of insulin, gastrin, secretin, prolactin, and certain tissue-specific enzymes have been invaluable in patient care. Further refinements of current methods, as well as the emergence of new immunoassay techniques, are expected to enhance precision, specificity, reliability, and convenience of the radioimmunoassay in both clinical and research laboratories

  14. Optimisation of sandwich ELISA based on monoclonal antibodies for the specific measurement of pregnancy-associated plasma protein (PAPP-A) in acute coronary syndrome

    DEFF Research Database (Denmark)

    Rossen, Marie; Iversen, Kasper; Teisner, Ane

    2007-01-01

    OBJECTIVES: PAPP-A has become the principal biochemical serum marker in first trimester screening for Down syndrome, the original data being based on results of a radioimmunoassay (RIA). Recent observations using sandwich ELISA technology have proposed PAPP-A as a potential marker in patients wit...

  15. Radioimmunoassay reagent and its use in a radioimmunoassay

    International Nuclear Information System (INIS)

    Polito, A.J.; Knight, W.S.

    1977-01-01

    A radioimmunoassay to detect or determine a steroid of the cortisone and aldosterone group has been developed. The invention particularly concerns a steroid derivative containing imidazole group which is radioactively labelled. The invented reagents are labelled with iodine 125. (VJ) [de

  16. Recent advances in steroid radioimmunoassay

    International Nuclear Information System (INIS)

    Jeffcoate, S.L.

    1977-01-01

    The advances since 1974 in the techniques of measuring steroid molecules by radioimmunoassay are reviewed in this paper. They are considered under the following headings: preparation and use of antisera; preparation and use of tracers; preparation of biological samples before assay; dispensing of the reagents in the assay; separation of free and bound radioactivity; counting and data processing; quality control and standardization. (orig.) [de

  17. A sensitive radioimmunoassay for fentanyl

    International Nuclear Information System (INIS)

    Michiels, M.; Hendriks, R.; Heykants, J.

    1977-01-01

    Antiserum to fentanyl was obtained in rabbits repeatedly injected with carboxyfentanyl conjugated to bovine serum albumin. Using the antiserum, a highly sensitive radioimmunoassay has been developed, based on the dextran-coated charcoal method. It proved possible to assay the drug directly in plasma, in amounts as small as 30 picogram in 0.5 ml. The antibody was highly specific for fentanyl and no cross-reaction was observed with its major metabolites. This sensitive and specific radioimmunoassay method was employed to determine fentanyl in plasma from six volunteers after an intravenous bolus of 0.2 mg, and in plasma from dogs treated both intravenously and subcutaneously with 0.02 mg/kg. The plasma level of fentanyl could be followed for up to 6 h after a therapeutic dose in dogs and man. (orig.) [de

  18. Radioimmunoassay for plasma renin activity

    International Nuclear Information System (INIS)

    1975-01-01

    A radioimmunoassay for the determination of renin activity in blood plasma is described. The plasma sample is mixed with a generator buffer solution also containing an inhibitor for enzymes which convert angiotensin I into other substances. The renin in the plasma sample converts angiotensinogen into angiotensin I. The amount of angiotensin I is then measured with a competitive binding method using 125 I-labelled angiotensin I and antibodies to angiotensin I

  19. Determination of phenobarbital by radioimmunoassay

    International Nuclear Information System (INIS)

    Yamaoka, A.; Takatori, T.

    1979-01-01

    A radioimmunoassay for phenobarbital has been studied. Antiphenobarbital antisera were obtained by repeated immunization of rabbits with p-succinamidophenobarbital conjugated to bovine serum albumin. Less than 0.2 pmol of phenobarbital could be measured by this procedure. The specificity of the antibodies was directed to substituents on the nitrogen atoms of the barbituric rings as well as to substituents at the carbon 5-position of the ring. (Auth.)

  20. Radioimmunoassays of papain in beer

    International Nuclear Information System (INIS)

    Rauch, P.; Fukal, L.; Strejcek, F.; Kas, J.

    1984-01-01

    A radioimmunoassay (RIA) of papain is described which is capable of detecting 0.2 μg of papain/ml in beer, a level approximately 1% of that normally used for chillproofing. Changes in incubation conditions significantly accelerate the papain determination with only slight loss of accuracy. Apart from the high sensitivity it has been shown that the method is highly specific and distinguishes papain from the other chillproofing enzymes used. (author)

  1. The promotion of radioimmunoassay in human health

    International Nuclear Information System (INIS)

    Dudley, R.A.

    1983-01-01

    Radioimmunoassay is an analytical technique which makes use of highly specific and sensitive antibodies to segregate particular substances of interest and radioactive tracers to permit quantification of minute amounts. Some procedures use specific biological ''reagents'' other than antibodies and tracers other than radionuclides. Radioimmunoassay plays an enormous role in medical diagnosis and research. Depending on the services to be performed, the radioimmunoassay laboratories are classified into 4 categories. The laboratory of each category is staffed and equipped with facilities according to its scope and quantity of work. From 1980-1982, nearly US$ 2 million had been used under the Agency's Technical Cooperation Programme for the promotion of radioimmunoassay in human health

  2. Promotion of radioimmunoassay in human health

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, R A [International Atomic Energy Agency, Vienna (Austria). Div. of Life Sciences

    1983-06-01

    Radioimmunoassay is an analytical technique which makes use of highly specific and sensitive antibodies to segregate particular substances of interest and radioactive tracers to permit quantification of minute amounts. Some procedures use specific biological ''reagents'' other than antibodies and tracers other than radionuclides. Radioimmunoassay plays an enormous role in medical diagnosis and research. Depending on the services to be performed, the radioimmunoassay laboratories are classified into 4 categories. The laboratory of each category is staffed and equipped with facilities according to its scope and quantity of work. From 1980-1982, nearly US $2 million had been used under the Agency's Technical Cooperation Programme for the promotion of radioimmunoassay in human health.

  3. New solid phase radioimmunoassay (CLB-RIA) for the detection of hepatitis-B antigen and antibody

    Energy Technology Data Exchange (ETDEWEB)

    Duimel, W J [Centraal Laboratorium van de Bloedtransfusiedienst, Amsterdam; Brummelhuis, H G.J.

    1975-07-01

    A new competitive solid phase radioimmunoassay (CLB-RIA) has been developed for the detection of HBAg and HBAb in human serum and plasma. In the assay, sheep antibodies to HBAg, covalently linked to an insoluble carrier, highly purified /sup 125/I labelled HBAg and the serum or plasma sample are incubated for 20 h at room temperature. After incubation, the bound and the free fraction of the tracer are separated by centrifugation. The presence of both HBAg and HBAb results in a decrease of the amount of bound tracer, when compared with a negative control serum. Differentiation between HBAg and HBAb requires the use of another type of radioimmunoassay. For this purpose a sandwich solid phase radioimmunoassay, for the detection of HBAb only, has been developed (CLB-AURIA). In this, assay-purified HBAg is covalently linked to an insoluble carrier. Using a mixture of both immunosorbents (insolubilized HBAg and HBAb), it is possible to detect and to distinguish HBAg and HBAb in one single solid phase radioimmunoassay (CLB-MIRIA). The influence of three parameters on the CLB-RIA, the incubation time, the amount of tracer and the effect of Tween-20 has been studied. The sensitivity of the described solid phase CLB-RIA for the detection of HBAg is comparable to that of other radioimmunoassays reported in literature; its specificity is very high.

  4. Development of Aircraft Sandwich Parts

    Directory of Open Access Journals (Sweden)

    J. Křena

    2000-01-01

    Full Text Available The presented paper shows the design and development process of sandwich parts. A spoiler plate and a main landing gear door are developed. Sandwich parts are made of C/E composite facings and a foam core. FE models have been used for optimization of structures. Emphasis has been placed on deformations of parts under a few load cases. Experimental tests have been used for a verification of structure parts loaded by concentrated forces.

  5. A sandwich immunoassay for human prolyl 4-hydroxylase using monoclonal antibody

    International Nuclear Information System (INIS)

    Yoshida, Shinichi

    1986-01-01

    Monoclonal antibody was used in a sandwich enzyme immunoassay and in a radioimmunoassay for human serum immunoreactive prolyl 4-hydroxylase. The enzyme immunoassay utilized a monoclonal antibody as a solid phase and horseradish peroxidase-labeled rabbit antibody to human prolyl 4-hydroxylase as a conjugate. Sensitivity was 0.1 ng of enzyme per tube. With a conjugate purified by an enzyme-bound affinity column, sensitivity was increased to 0.01 ng per tube, and linearity was obtained between 0.01 to 30 ng per tube. The radioimmunoassay used a 125 I-labeled rabbit antibody (IgG) as the conjugate. Sensitivity of this technique was 0.4 ng of enzyme per tube. (Auth.)

  6. Radioimmunoassay method for detection of gonorrhea antibodies

    International Nuclear Information System (INIS)

    1975-01-01

    A novel radioimmunoassay for the detection of gonorrhea antibodies in serum is described. A radionuclide is bound to gonorrhea antigens produced by a growth culture. In the presence of gonorrhea antibodies in the serum, an antigen-antibody conjugate is formed, the concentration of which can be measured with conventional radiometric methods. The radioimmunoassay is highly specific

  7. A radioimmunoassay for abscisic acid

    International Nuclear Information System (INIS)

    Walton, D.; Dashek, W.; Galson, E.

    1979-01-01

    We have developed a radioimmunoassay (RIA) for abscisic acid (ABA) in the 0.1 ng to 2.5 ng range. Antibodies were obtained from rabbits immunized with ABA bound via its carboxyl group to bovine serum albumin. Cross-reactivity studies indicate that ABA esters are completely cross-reactive with ABA, while trans, trans abscisic acid (t-ABA) phaseic acid (PA) and dihydrophaseic acid (DPA) have much lower but significant cross-reactivities. Purification methods which reduce the levels of cross-reacting substances are described. (orig.) 891 AJ/orig. 892 MKO [de

  8. Radioimmunoassay and other related techniques

    International Nuclear Information System (INIS)

    Zarkawi, Moutaz

    1993-04-01

    The article reviews principles, requirements and reliability criteria of radioimmunoassay (RIA). Since basic reactions involved in RIA and related techniques are derived from reactions which take place in the immune system (IS) of humans and animals, the IS and the way it works will be described. In addition to RIA which involves the use of isotopes as tracers (labels), other non-radioisotopic and recent immunoassay techniques i.e. enzyme-linked immunosorbent assay (ELISA), chemiluminescence immunoassay (CLIA) and fluoroimmunoassay (FIA) will be dealt with. Some important and related terms will be defined and explained. (author). 59 refs., 4 figs

  9. Radioimmunoassay of cholylglycine in serum

    International Nuclear Information System (INIS)

    Wakushima, Tadashi; Yamanishi, Yasuhito; Hirayama, Chisato

    1979-01-01

    Serum levels of cholylglycines (CG) were determined by radioimmunoassay and that of total bile acids (TBA) by enzymatic method. In normal subjects, serum levels of CG, TBA and CG/TBA ratio were 0.6 +- 0.4 μM, 7 +- 2 μM, and 0.08 +- 0.06, respectively. They were increased markedly in acute hepatitis and moderately in chronic hepatitis and cirrhosis. Thus, measurement of serum CG as compared with serum TBA appears to be a sensitive liver test. (author)

  10. Radioimmunoassay in children with glomerulonephritis

    International Nuclear Information System (INIS)

    Ametov, A.S.; Gavryushova, L.P.; Shashinka, M.; Mumladze, Eh.B.; Tvorogova, T.M.; Dakhuk, B.; Dronova, V.I.; Toritsina, D.K.; Petrova, T.V.

    1985-01-01

    Proceeding from a radioimmunoassay of various biologically active substances in the blood and urine (ACTH, cortisol, FSH, LH, prolatin, progesterone, estradiol, plasma renin activity and β 2 -microglobulin) of 220 children with glomerulonephritis change of all indices with relation to the type and gravity of glomerulonephritis as well as renal function was revealed. The nature of influence on corticosteroid and immunosuppressive therapy was shown. The authors consider it appropriate to use the determination of biologically active substances in the blood and urine for a more profound estimation of a child's status

  11. Heterologous radioimmunoassay for arginine vasopressin

    International Nuclear Information System (INIS)

    Shimamoto, K.; Murase, T.; Yamaji, T.

    1976-01-01

    A sensitive and specific radioimmunoassay for arginine vasopressin (AVP) was developed utilizing the antisera against lysine vasopressin (LVP) in combination with a labeled AVP. The assay employs an acetone extraction procedure and detects as little as 0.8 pg. per millimeter of AVP in human plasma. In normal subjects, the mean (+- S.D.) plasma concentration of AVP was 4.9 +- 1.2 pg. per milliliter after fluid deprivation and 1.2 +- 0.4 pg. per milliliter after water loading. Plasma AVP levels correlated significantly with plasma osmolalities. In four patients with diabetes insipidus, plasma AVP concentrations ranged from less than 0.8 to 1.2 pg. per milliliter, whereas six patients with the syndrome of inappropriate ADH secretion showed plasma levels of AVP which correspond to those of the dehydrated state in normal subjects or greater, although plasma osmolalities were low in all cases. It was concluded that the present radioimmunoassay method for AVP provides a useful way of assessing neurohypophyseal function in man

  12. Apparatus for use in radioimmunoassays

    International Nuclear Information System (INIS)

    Chen, C-H.; Tsay, H-M.; Heyer, R.E.

    1979-01-01

    Apparatus for solid-phase antibody separation techniques used in radioimmunoassays is described in this invention. It consists of a rectangular prism tray with multiple wells protruding into its interior from one side. Near the base of the tray is an orifice used for creating evacuated condition within the structure. At the base of each well there is an orifice of such size and shape as to retain an aqueous liquid under given pressure conditions but permit the evacuation of this liquid at reduced pressure. The outlet of these orifices is in the shape of an inverted conical frustrum. Each of the wells contains an antibody coated disc of porous cellulose paper surrounded by a plastic support. The porous nature of the cellulose paper ensures contact between the antibody coating and the antigen. The use of antibody coated porous cellulose paper in combination with the vacuum operated apparatus simplifies the manipulative steps whilst still maintaining the sensitivity of the radioimmunoassay. It also obviates the need for aspiration and thus lessens the risk of contamination from one sample to another. (UK)

  13. Radioimmunoassay of total IgE and allergen-specific IgE antibodies with a uniform indicator system in allergies of childhood

    International Nuclear Information System (INIS)

    Struy, H.; Schuster, R.; Sollich, V.; Thal, W.; Morenz, J.

    1984-01-01

    Solid-phase radioimmunoassays for the determination of allergen-specific and total IgE have been developed. In an indirect solid-phase radioimmunoassay for the measurement of allergen-specific antibodies PVC blisters coated with allergens and in a sandwich solid-phase radioimmunoassay blisters coated with antihuman IgE antibodies are incubated sequentially with patient serum, unlabelled antihuman IgE from rabbits purified by affinity chromatography, and finally with antirabbitglobulin from sheep. Antirabbitglobuline was purified by immunoadsorption. The 125 I-labelled antibody with a specific activity of 30 kBq/μg antibody protein could be used universally for the determination of antibodies of each immunoglobulin class. In 160 patients mostly with seasonal asthma these assays supported RAST and PRIST kits and were helpful in the diagnosis of atopic diseases. (author)

  14. Structural and failure mechanics of sandwich composites

    CERN Document Server

    Carlsson, LA; Carlsson, Leif A

    2011-01-01

    Focusing on important deformation and failure modes of sandwich structures, this volume describes the mechanics behind fracture processes. The text also reviews test methods developed for the cr, structural integrity, and failure mechanisms of sandwich structures.

  15. A sensitive radioimmunoassay for colchicine

    International Nuclear Information System (INIS)

    Scherrmann, J.M.; Boudet, L.; Pontikis, R.; Nguyen-Hoang-Nam; Fournier, E.

    1980-01-01

    A sensitive and rapid radioimmunoassay for colchicine was developed using an antibody raised in goats after injection of N-desacetylthiocolchicine conjugated with bovine serum albumin. The incubation time is short and dextran-coated charcoal was used for the separation. The sensitivity of the assay was 0.35 ng/ml urine or serum. A low cross-reactivity was observed with colchicine derivatives and the other drugs tested. The RIA was applied to the measurement of colchicine in the serum of a patient given a 1mg oral dose of the drug. Peak levels of colchicine were attained at 2 hrs. following administration and the drug was rapidly distributed, the concentration decreasing to < 1 ng/ml by 8 hrs. The 24 and 48 hr. concentrations indicated a prolonged excretion of colchicine and a long elimination half-time. (U.K.)

  16. Radioimmunoassay for nortriptyline and amitriptyline

    International Nuclear Information System (INIS)

    Turner, P.

    1977-01-01

    A description has been given (Aherne, G.W.; Marks, V.; Mould, G.; Stout, G.; Lancet; 1214, June 4 (1977)) of a radioimmunoassay (RIA) technique having advantages for monitoring patient response by estimation of plasma concentrations of nortriptyline and amitriptyline. A wide range of monoamine-reuptake-inhibiting drugs is now used in the treatment of depressive illness. There are other analytical techniques such as gas-liquid chromatography which can be used in the estimation of most of these drugs and their major metabolites, as well as for the identification of some other centrally-acting drugs such as benzodiazepines. The chromatographic technique was able to detect the administration of the wrong drug in one comparative study of two antidepressive drugs. Chromatographic and RIA methods therefore both have their own analytical roles according to the clinical or research problem being investigated. (U.K.)

  17. Improved radioimmunoassay of plasma cortisol

    International Nuclear Information System (INIS)

    Donohue, J.; Sgoutas, D.

    1975-01-01

    We report a simplified radioimmunoassay procedure for determination of plasma cortisol. The method offers the advantage that tracer, antibody, and assay buffer are added in a single step with the use of semi-automated equipment. Thus, critical pipetting procedures are minimized, and assay time is reduced to 4 h. No prior extraction or chromatographic purification of cortisol is required. The procedure is simple, reliable, and accurate. For either between-assay or within-assay determinations, the coefficients of variation are about 6 percent. Our results compare well with those obtained from a procedure that included extraction and chromatographic purification of cortisol in several plasma samples. Conditions for optimizing the assay are also discussed. (auth)

  18. Preparation of albumin radioimmunoassay kit

    International Nuclear Information System (INIS)

    Chen Suoshu; Wang Yanzhen; Wang Zhenshan

    1990-01-01

    This paper presents the preparation of Albumin (Alb) radioimmunoassay kit and its preliminary clinical application. The kit is mainly applied to the measurement of Alb concentration in human urine, adopting second antibody-PEG method. The measurement range is (1-50 μg/ml). The curve obtained with a serially diluted urine sample of high Alb concentration was a straight line. Recovery, detectability, intra- and inter-batch variation coefficients were 95.7%-103.6%, 0.1 μg/ml, 5.8% and 6.4% respectively. The kit was tried out clinically for measuring Alb in urine samples in about 1200 normal individuals and 600 various patients of related renal diseases. The preliminary clinical results show that Alb RIA is conducive to the early diagnosis of kidney function abnormalities

  19. Methadone radioimmunoassay: two simple methods

    International Nuclear Information System (INIS)

    Robinson, K.; Smith, R.N.

    1983-01-01

    Two simple and economical radioimmunoassays for methadone in blood or urine are described. Haemolysis, decomposition, common anticoagulants and sodium fluoride do not affect the results. One assay used commercially-available [1- 3 H](-)-methadone hydrobromide as the label, while the other uses a radioiodinated conjugate of 4-dimethylamino-2,2-diphenylpentanoic acid and L-tyrosine methyl ester. A commercially-available antiserum is used in both assays. Normethadone and α-methadol cross-react to a small extent with the antiserum while methadone metabolites, dextropropoxyphene, dipipanone and phenadoxone have negligible cross-reactivities. The 'cut-offs' of the two assays as described are 30 and 33 ng ml -1 for blood, and 24 and 21 ng ml -1 for urine. The assay using the radioiodinated conjugate can be made more sensitive if required by increasing the specific activity of the label. (author)

  20. High temperature structural sandwich panels

    Science.gov (United States)

    Papakonstantinou, Christos G.

    High strength composites are being used for making lightweight structural panels that are being employed in aerospace, naval and automotive structures. Recently, there is renewed interest in use of these panels. The major problem of most commercial available sandwich panels is the fire resistance. A recently developed inorganic matrix is investigated for use in cases where fire and high temperature resistance are necessary. The focus of this dissertation is the development of a fireproof composite structural system. Sandwich panels made with polysialate matrices have an excellent potential for use in applications where exposure to high temperatures or fire is a concern. Commercial available sandwich panels will soften and lose nearly all of their compressive strength temperatures lower than 400°C. This dissertation consists of the state of the art, the experimental investigation and the analytical modeling. The state of the art covers the performance of existing high temperature composites, sandwich panels and reinforced concrete beams strengthened with Fiber Reinforced Polymers (FRP). The experimental part consists of four major components: (i) Development of a fireproof syntactic foam with maximum specific strength, (ii) Development of a lightweight syntactic foam based on polystyrene spheres, (iii) Development of the composite system for the skins. The variables are the skin thickness, modulus of elasticity of skin and high temperature resistance, and (iv) Experimental evaluation of the flexural behavior of sandwich panels. Analytical modeling consists of a model for the flexural behavior of lightweight sandwich panels, and a model for deflection calculations of reinforced concrete beams strengthened with FRP subjected to fatigue loading. The experimental and analytical results show that sandwich panels made with polysialate matrices and ceramic spheres do not lose their load bearing capability during severe fire exposure, where temperatures reach several

  1. Radioimmunoassay method for triiodothyronine and thyroxine

    International Nuclear Information System (INIS)

    Hollander, C.S.

    1975-01-01

    This invention relates to a radioimmunoassay method for triiodothyronine or thyroxine or triiodothyronine and thyroxine present in unextracted serum containing thyroxine binding prealbumin and thyroxine binding globulin. Procedures using 125 I and 131 I are described

  2. Measurement of antibodies to tubulin by radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Mead, G M; Cowin, P; Whitehouse, J M.A. [CRC Medical Oncology Unit, Southampton General Hospital, Southampton, U.K.

    1979-07-24

    A solid-phase double antibody radioimmunoassay capable of measuring antibody to tubulin, the principal component of microtubules, is described. This assay is simple, combining sensitivity with specificity and also allowing determination of antibody subclasses.

  3. Validation of a radioimmunoassay for rat insulin

    International Nuclear Information System (INIS)

    Delattre, E.; Boschero, A.C.

    1984-01-01

    A methodological approach that permits, in a radioimmunoassay, the evaluation of rat insulin by using bovine insulin as reference is presented. As in general the technics for radioimmunoassay of different substances follow the same principles (competitive inhibition), we believe that the methodology presented here could be used for evaluation of other hormones when the adequated referential, of know biological activity, is not available. (Author) [pt

  4. Automated, computer interpreted radioimmunoassay results

    International Nuclear Information System (INIS)

    Hill, J.C.; Nagle, C.E.; Dworkin, H.J.; Fink-Bennett, D.; Freitas, J.E.; Wetzel, R.; Sawyer, N.; Ferry, D.; Hershberger, D.

    1984-01-01

    90,000 Radioimmunoassay results have been interpreted and transcribed automatically using software developed for use on a Hewlett Packard Model 1000 mini-computer system with conventional dot matrix printers. The computer program correlates the results of a combination of assays, interprets them and prints a report ready for physician review and signature within minutes of completion of the assay. The authors designed and wrote a computer program to query their patient data base for radioassay laboratory results and to produce a computer generated interpretation of these results using an algorithm that produces normal and abnormal interpretives. Their laboratory assays 50,000 patient samples each year using 28 different radioassays. Of these 85% have been interpreted using our computer program. Allowances are made for drug and patient history and individualized reports are generated with regard to the patients age and sex. Finalization of reports is still subject to change by the nuclear physician at the time of final review. Automated, computerized interpretations have realized cost savings through reduced personnel and personnel time and provided uniformity of the interpretations among the five physicians. Prior to computerization of interpretations, all radioassay results had to be dictated and reviewed for signing by one of the resident or staff physicians. Turn around times for reports prior to the automated computer program generally were two to three days. Whereas, the computerized interpret system allows reports to generally be issued the day assays are completed

  5. Radioimmunoassay of human urinary kallikrein

    International Nuclear Information System (INIS)

    Goering, W.

    1980-01-01

    Using a human urinary kallikrein, purified by means of Trasylol sepharose, it has been possible to develop a radioimmunoassay of kallikrein capable of detecting the substance down to a concentration of 0.5 ng/ml. The specific activity of the tracer labelled with 125-iodine using the Chloramine-T method was 30-70 nCi/ng of kallikrein. The antiserum titres for the antikallikrein serum were 1:20.000 up to 1:50.000. Human urine, submandibular and parotid salivae as well as pancreatic secretion in this RIA reacted in the same manner as the kallikrein standard solution. The kallikrein content in urine, as determined by the RIA was between 0 and 300 ng/ml, in the saliva between 400 and 2.000 ng/ml, and in the pancreatic juice between 300 and 12.000 ng/ml. Using human serum, only an incomplete immunological cross-reaction could be achieved. In human liquor as well as in animal preparation, no cross-reacting substances could be detected. (orig.) [de

  6. Radioimmunoassay of triiodothyronine in urine

    International Nuclear Information System (INIS)

    Kosowicz, J.; Gembicki, M.; Schneider, E.; Eder, M.

    1977-01-01

    In 21 cases of hypothyroidism, in 39 cases of hyperthyroidism, in 54 healthy subjects, in 23 pregnant women, and in certain internal diseases determinations of triiodothyronine were carried out in urine by radioimmunoassay. Anti-T 3 antibodies were obtained in rabbits and sheep immunized with a complex of bovine albumin with triiodothyronine ester. Labelled triiodothyronine of high specific activity was obtained by iodinating triodothyronine by the chloramine method. Determinations of triiodothyronine were performed in morning urine and the obtained values were calculated for one-hour excretion. In healthy subjects the excretion of T 3 was from 20 to 95 ng/hour, in hyperthyroidism it was significantly raised to from 120 to over 600 ng/hour, while in most cases of hypothyroidism it was decreased. In pregnancy the urinary excretion of T 3 was normal amounting to from 34 to 87 ng/hour, although in most cases the serum T 3 concentration was raised. In cases of anorexia nervosa and in obese starving subjects the excretion of T 3 fell significantly, and similarly low excretion was found in some cases of debilitating diseases and myocardial infarction. (author)

  7. Radioimmunoassay of canine growth hormone

    International Nuclear Information System (INIS)

    Eigenmann, J.E.; Eigenmann, R.Y.

    1981-01-01

    A sensitive radioimmunoassay (RIA) for canine growth hormone (GH) was developed. Antibodies were elicited in rhesus monkeys. One antiserum exhibited a working titer at a dilution of 1:500 000. Radioiodination was performed enzymatically employing lactoperoxidase. Logit-log transformation and least squares fitting resulted in straight line fitting of the standard curve between 0.39 and 50 ng/ml. Formation of large-molecular [ 125 I]GH during storage caused diminished assay sensitivity. Therefore [ 125 I]GH was re-purified by gel chromatography. Using this procedure, high and reproducible assay sensitivity was obtained. Tracer preparations were used for as long as 3 months after iodination. Diluted plasma from normal and acromegalic dogs resulted in a dose-response curve parallel to the standard curve. Canine prolactin exhibited a cross-reactivity of 2%. The within-assay coefficient of variation (CV) was 3.8 and the between-assay CV was 7.2%. Mean plasma GH concentration in normal dogs was 1.92 +- 0.14 ng/ml (mean +- SEM.) GH levels in acromegalic dogs were appreciably higher. Insulin-induced hypoglycaemia, arginine and ornithine administration resulted in inconsistent and sluggish GH increment. A better response was obtained by injecting a low dose of clonidine. Clonidine administration to hypopituitary dogs resulted in absent or poor GH increment. (author)

  8. Improved radioimmunoassay for human TSH

    International Nuclear Information System (INIS)

    Spencer, C.A.; Nicoloff, J.T.

    1980-01-01

    This study concerns the optimization of the human TSH (h-TSH) radioimmunoassay with special emphasis on reducing the heterogeneity of the 125 I h-TSH tracer. Enzymatic iodination of h-TSH with glucose oxidase/lactoperoxidase was shown to be superior to either low or high dose chloramine-T procedures, producing a high specific activity reagent (70-150 μCi/μg) with minimal evidence of damage. Tracer purification procedures not only affected initial immunoactivity but also storage stability and heterogeneity of the resulting 125 I h-TSH. The assay developed using these technical approaches shows a sensitivity limit of 0.005+-0.001 (S.E.M.) μU/tube; 50% displacement at 0.18+-0.08 (S.E.M.) μU/tube and complete delineation between euthyroid (n=49, 2.44+-0.18 (S.E.M.) mU/l, range 1.00-6.08) and hyperthyroid (n=62, 0.34+-0.02 (S.E.M.) mU/l, range 0.10-0.85), serum h-TSH levels. (Auth.)

  9. Haplotype inference in general pedigrees with two sites

    Directory of Open Access Journals (Sweden)

    Doan Duong D

    2011-04-01

    Full Text Available Abstract Background Genetic disease studies investigate relationships between changes in chromosomes and genetic diseases. Single haplotypes provide useful information for these studies but extracting single haplotypes directly by biochemical methods is expensive. A computational method to infer haplotypes from genotype data is therefore important. We investigate the problem of computing the minimum number of recombination events for general pedigrees with two sites for all members. Results We show that this NP-hard problem can be parametrically reduced to the Bipartization by Edge Removal problem and therefore can be solved by an O(2k · n2 exact algorithm, where n is the number of members and k is the number of recombination events. Conclusions Our work can therefore be useful for genetic disease studies to track down how changes in haplotypes such as recombinations relate to genetic disease.

  10. Theoretical and practical application of radioimmunoassays

    International Nuclear Information System (INIS)

    Sokolowski, G.; Wood, W.G.

    1981-01-01

    This book describes experiences made not only in developing and producing commercial reagent kits, but also those made in university research and diagnostic laboratories. The fundamental principles (radioactivity, immunoassay) are explained briefly and tersely. Then the components of the radioimmunoassay are described in detail and illustrated by selected practical examples (production of antibodies, separation of bound and free portions, standards). This chapter is followed by systematic instructions for composing a radioimmunoassay. The actual conditions of the complex problem of quality safety is explained, a field in which particularly the authors are to be regarded as pioneers. Finally an outlook indicates that radioactive alternatives, incorporating the principle of immunologic determinations methods, are available or will be developed for at least a few radioimmunoassays. (orig./MG) [de

  11. Assessment of the specificity of norethisterone radioimmunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Bedolla-Tovar, N; Rahman, S A; Cekan, S Z; Diczfalusy, E [Swedish Medical Research Council, Karolinska Hospital, Stockholm

    1978-06-01

    It is concluded that (1) the significance of cross- reaction studies as well as that of the parallelism test for the assessment of the over-all specificity of the assay is limited, (2) a single chromatography prior to the radioimmunoassay proper improves the assay specificity, but may not be sufficient to remove all interfering compounds, (3) a comparison of the direct and chromatographic assay procedures using several antisera is useful for the selection of the relatively most specific radioimmunoassay procedure. In the present study, this is the technique employing either antiserum C or antiserum D, the latter, however, only after chromatography.

  12. Neurons with two sites of synaptic integration learn invariant representations.

    Science.gov (United States)

    Körding, K P; König, P

    2001-12-01

    Neurons in mammalian cerebral cortex combine specific responses with respect to some stimulus features with invariant responses to other stimulus features. For example, in primary visual cortex, complex cells code for orientation of a contour but ignore its position to a certain degree. In higher areas, such as the inferotemporal cortex, translation-invariant, rotation-invariant, and even view point-invariant responses can be observed. Such properties are of obvious interest to artificial systems performing tasks like pattern recognition. It remains to be resolved how such response properties develop in biological systems. Here we present an unsupervised learning rule that addresses this problem. It is based on a neuron model with two sites of synaptic integration, allowing qualitatively different effects of input to basal and apical dendritic trees, respectively. Without supervision, the system learns to extract invariance properties using temporal or spatial continuity of stimuli. Furthermore, top-down information can be smoothly integrated in the same framework. Thus, this model lends a physiological implementation to approaches of unsupervised learning of invariant-response properties.

  13. Immunoradiometric versus radioimmunoassay: a comparison using alpha-fetoprotein as the model analyte

    International Nuclear Information System (INIS)

    Hunter, W.M.; Budd, P.S.

    1981-01-01

    With alpha-fetoprotein as a model a formal comparison has been made between inhibition type radioimmunoassay with radioiodinated antigen, liquid-phase incubation and double antibody separation (RIA) and variants of the sandwich immunoradiometric assay (IRMA). 125 I-antibody was prepared (expensively) by labelling the IgG fraction and subsequently undertaking immunopurification to yield a reproducibly-high quality reagent, 70-75% being reactive with antigen. The same antiserum was coupled to Sepharose 4B for use in the IRMA and separation was by the sucrose layer procedure (Hunter, 1980) which obviates the need for centrifugation. The principal basis used for the comparison was computer-generated precision profiles (Ekins, 1976), each of which was derived from 10 assays of each kind. (Auth.)

  14. Solid phase radioimmunoassays using labelled antibodies: a conceptual framework for designing assays

    International Nuclear Information System (INIS)

    Kalmakoff, J.; Parkinson, A.J.; Crawford, A.M.; Williams, B.R.G.

    1977-01-01

    A simple theoretical model for the antigen-antibody reaction is presented and used to evaluate the optimum conditions for designing solid phase radioimmunoassays (RIA) using labelled antibodies. Both theoretical and experimental data are presented, using a wide variety of antigens and their corresponding antibodies. The types of RIA described include the direct, the indirect, the direct sandwich assays for detecting either antigen or antibody. The experimental results confirm in a semiquantitative manner that the greatest sensitivity of the RIA is achieved when the smallest amount of labelled antibody is used, that whenever possible the antigen/antibody ratio should be greater than unity(>1), and that the formation of the antigen-antibody complex is dependent on the mass action effect

  15. Radioimmunoassay for platelet activation specific protein GMP-140 on the platelet surface and in plasma

    International Nuclear Information System (INIS)

    Wu Guoxin; Li Jianyong; Ruan Changgeng

    1991-08-01

    Using monoclonal antibody (McAb) SZ-51 which is specific for an alpha-granule membrane protein (GMP-140) on the surface of human activated platelets, the platelet GMP-140 expression in fixed whole blood was measured by direct radioimmunoassay and GMP-140 microparticles in plasma was measured by sandwich method. The GMP-140 molecules per platelet or milliliter (mL) were calculated for the following subjects; acute myocardial infarction; cerebro thrombosis; diabetic mellitus; asthma attack; epidemic hemorrhagic fever etc.. By comparing with the concentration of thromboxane B 2 (TXB 2 ) and von Willebrand factor (vWF) in plasma, it is confirmed that the measurement of GMP-140 molecules is better than that of TXB 2 and vWF. It is a sensitive and specific method for evaluating the platelet activation degree in vivo. The establishment of this method will be useful to diagnosing the thrombotic disorders and studying the pathogenesis of some other diseases

  16. Solid phase tube radioimmunoassay for digoxin detection

    International Nuclear Information System (INIS)

    Stellner, K.; Glatz, C.; Linke, R.

    1975-01-01

    A solid phase radioimmunoassay with 125 I is described for cardiac patients. The test for the digoxin determination and the poisoning due to cardiac glycosides can be measured very accurately and carried out easily. In addition, the test determination can be automatically performed in connection with other tests. (GSE/LH) [de

  17. Adsorption columns for use in radioimmunoassays

    International Nuclear Information System (INIS)

    1976-01-01

    Adsorption columns are provided which can be utilized in radioimmunoassay systems such as those involving the separation of antibody-antigen complexes from free antigens. The preparation of the columns includes the treatment of retaining substrate material to render it hydrophilic, preparation and degassing of the separation material and loading the column

  18. Rationale for the development of radioimmunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Roulston, J E; Adam, T [Charing Cross Group of Hospitals, London (UK)

    1978-02-01

    A theoretical study of the principles of radioimmunoassay and allied techniques is presented with a view to the application in practical developmental research. Both equilibrium and sequential saturation methods are discussed and their respective advantages noted. Simple methods for the estimation of the affinity constant by saturation techniques and use of the Scatchard plot are outlined.

  19. Determination of serum IgD radioimmunoassay

    International Nuclear Information System (INIS)

    Fayol, V.; Hartmann, D.J.; Sabbagh, I.; Ville, G.

    1986-01-01

    We describe a sensitive liquid phase radioimmunoassay for serum IgD. Extreme values obtained from 85 control patients sera are 0.2 and 121 mg/l with an arithmetic mean of 25 mg/l. In atopic patients (with high serum IgE levels), arithmetic mean is 47 mg/l [fr

  20. Determination of serum IgD radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Fayol, V.; Hartmann, D.J.; Sabbagh, I.; Ville, G.

    1986-01-01

    We describe a sensitive liquid phase radioimmunoassay for serum IgD. Extreme values obtained from 85 control patients sera are 0.2 and 121 mg/l with an arithmetic mean of 25 mg/l. In atopic patients (with high serum IgE levels), arithmetic mean is 47 mg/l.

  1. Improved radioimmunoassay for thyroid hormone and reagent

    International Nuclear Information System (INIS)

    1980-01-01

    Improvements in the radioimmunoassay of the thyroid hormones, thyroxine or triiodothyronine, are described. Hydrolyzed cross-linked polyacrylamide particles covalently bonded against the thyroid hormone are employed as solid phase substrates for the thyroid hormone antibodies. The polyacrylamide particles are dyed yellow or blue to facilitate the various manipulative steps during the radioimmunoassay. The particles are characterized by their ability to form stable hydrophilic suspensions. As a result the reaction mixture, during which thyroid hormone is separated from serum proteins and competitive binding in the presence of radioactive tracer with the antibody occurs, requires no agitation to maintain the desired homogeneous condition. This is in contrast to the settling problems experienced with cellulose, dextran and glass particles. In addition, the non-specific binding property of the polyacrylamide particles is so low that the initially separated solid phase particles following incubation can be directly measured for radioactivity levels without any initial washings thus increasing the speed and convenience of the assay procedure. Details of the preparation of the dyed, hydrolyzed polyacrylamide particles, the coupling of antiserum to these particles and the radioimmunoassay procedure are given. Data obtained from the radioimmunoassays of hypothyroid, euthyroid and hyperthyroid sera demonstrated the satisfactory performance of the assay. (U.K.)

  2. Evaluation of radioimmunoassay data by a minicomputer

    International Nuclear Information System (INIS)

    Venot, A.; Ingrand, J.; Roucayrol, J.C.; Valeyre, J.; Deltour, G.

    1977-01-01

    A program is proposed for routine use in every radioimmunoassay laboratory part of a bigger unit such as a department of nuclear medicine. Its main features are maniability and ability to avoid undue effects of outlying experimental values. A non specialized technician can operate himself, the data being fed off-line by a paper tape into a Multi 8 Intertechnique minicomputer [fr

  3. Advanced Mechanical Testing of Sandwich Materials

    DEFF Research Database (Denmark)

    Hayman, Brian; Berggreen, Christian; Jenstrup, Claus

    2008-01-01

    An advanced digital optical system has been used to measure surface strains on sandwich face and core specimens tested in a project concerned with improved criteria for designing sandwich X-joints. The face sheet specimens were of glass reinforced polyester and were tested in tension. The core sp...

  4. Sound transmission loss of composite sandwich panels

    Science.gov (United States)

    Zhou, Ran

    Light composite sandwich panels are increasingly used in automobiles, ships and aircraft, because of the advantages they offer of high strength-to-weight ratios. However, the acoustical properties of these light and stiff structures can be less desirable than those of equivalent metal panels. These undesirable properties can lead to high interior noise levels. A number of researchers have studied the acoustical properties of honeycomb and foam sandwich panels. Not much work, however, has been carried out on foam-filled honeycomb sandwich panels. In this dissertation, governing equations for the forced vibration of asymmetric sandwich panels are developed. An analytical expression for modal densities of symmetric sandwich panels is derived from a sixth-order governing equation. A boundary element analysis model for the sound transmission loss of symmetric sandwich panels is proposed. Measurements of the modal density, total loss factor, radiation loss factor, and sound transmission loss of foam-filled honeycomb sandwich panels with different configurations and thicknesses are presented. Comparisons between the predicted sound transmission loss values obtained from wave impedance analysis, statistical energy analysis, boundary element analysis, and experimental values are presented. The wave impedance analysis model provides accurate predictions of sound transmission loss for the thin foam-filled honeycomb sandwich panels at frequencies above their first resonance frequencies. The predictions from the statistical energy analysis model are in better agreement with the experimental transmission loss values of the sandwich panels when the measured radiation loss factor values near coincidence are used instead of the theoretical values for single-layer panels. The proposed boundary element analysis model provides more accurate predictions of sound transmission loss for the thick foam-filled honeycomb sandwich panels than either the wave impedance analysis model or the

  5. New "sandwich" structures conformed from three dimensional

    Directory of Open Access Journals (Sweden)

    Alba, Juan J.

    1996-03-01

    Full Text Available Poor interlaminar properties as well as poor-skin-to-core adhesion properties are very often the common existing problems we find when designing with "sandwich" structures. A new type of 3D-fabric "sandwich" structure is being developed in order to avoid these problems. Although the manufacturing process is very simple, a very complex "sandwich" structure is obtained as a result of the complexity of the 3D-fabric used. This 3D-fabric is a 3D woven glass fabric produced on velvet weaving machines with glass yarns. It is an integrally woven "sandwich" laminate for all kinds of composite products. The strength of the vertical fibers makes, that also after impregnation with a resin matrix, the "sandwich" structure is maintained. The result is a laminate with high strength and stiffness and low weight. On each side of this "sandwich" laminate additional reinforcement materials can be laminated and a synthetic foam can be injected in the hollow structure. This will allow to establish the mechanical properties of a finished product.

    Las pobres propiedades, tanto interlaminares como de adhesión entre piel y núcleo, constituyen uno de los grandes problemas cuando se diseñan estructuras utilizando paneles tipo "sandwich". Un nuevo tipo de panel "sandwich", configurado a partir de tejidos tridimensionales, está siendo desarrollado en la actualidad con el objetivo de eliminar esos problemas. Aunque el proceso de fabricación es muy simple, el panel "sandwich" obtenido es de estructura compleja, como resultado de la complejidad del tejido tridimensional utilizado. Este tejido tridimensional (3D es un tejido de fibra de vidrio producido en máquinas de tejer especializadas. La resistencia de las fibras verticales hace que, después de la impregnación con una resina, se mantenga la configuración tipo "sandwich". El resultado es un laminado de alta resistencia, gran rigidez y bajo peso. Sobre cada uno de los lados del panel "sandwich" se pueden

  6. Immunochemical heterogeneity of calcitonin in man: effect on radioimmunoassay

    International Nuclear Information System (INIS)

    Snider, R.H.; Moore, C.F.

    1977-01-01

    Determinations of blood levels of human calcitonin by radioimmunoassay have varied considerably in different laboratories. Much of the controversy over calcitonin levels can be attributed to the multiplicity of immunoreactive forms of the hormone (iCT), the differing region specificities of the antisera utilized for measurement by radioimmunoassay, protein effects, different rates of degradation of the various iCT fractions and the specific methodology of the radioimmunoassay

  7. Programs for radioimmunoassays and radioreceptorassays using SPSS-X.

    Science.gov (United States)

    Amador, A G; Hodges, S L

    1989-01-01

    Two sets of programs written using SPSS-X, and designed for the analysis of data obtained by radioimmunoassay or radioreceptorassay are presented. The main advantages of the programs are that they are easily edited, their commands are simple and logical, and they can be used for any type of radioimmunoassay or radioreceptorassay, respectively. The programs for radioimmunoassay can also be used for fluorescenceimmunoassay and luminescenceimmunoassay.

  8. Radioimmunoassay of deoxynivalenol in wheat and corn

    International Nuclear Information System (INIS)

    Xu, Y.C.; Zhang, G.S.; Chu, F.S.

    1986-01-01

    With the availability of antibody against deoxynivalenol triacetate (DON-triacetate), a radioimmunoassay (RIA) for DON in wheat was developed. DON is extracted from the sample with acetonitrile-water defatted with hexane, and then reacted with acetic anhydride to form DON-triacetate. The reaction mixture is loaded onto a C-18 cartridge to remove excess reagents and impurities. Acetylated DON is eluted from the cartridge with 50% methanol in water, and then analyzed by radioimmunoassay utilizing antiserum against DON-triacetate and tritiated DON-triacetate. Overall recovery for DON added to wheat between 50 and 5000 ppb was 86% with a standard deviation of 7% and coefficient of variation of 8%. The limit of detection for DON was about 20 ppb. Analysis of 12 naturally contaminated wheat, corn, and mixed feed samples for DON revealed that RIA results agreed well with thin layer chromatographic analyses performed by other laboratories

  9. 125I Radioimmunoassay of serum ursodeoxycholyl conjugates

    International Nuclear Information System (INIS)

    Hill, A.; Ross, P.E.; Bouchier, I.A.D.

    1983-01-01

    A radioimmunoassay for serum ursodeoxycholic conjugates using an iodine-125 ligand has been developed. The bile acid was present in normal fasting serum (0.19 +- SD 0.19 μmol/l, n=24) and 2-hour post-prandial serum (0.8 +- SD 0.8 μmol/l, n=16). Gallstone patients undergoing oral ursodeoxycholic acid therapy had significantly higher post-prandial serum levels (21.5 +- SD 14.0 μmol/l, n=15) by radioimmunoassay. Gas liquid chromatography analysis indicated that in normal serum ursodeoxycholic acid was totally conjugated, whereas sera from gallstone patients contained a proportion as the free bile acid (10.2 +- SD 8.1 μmol/l, n=15). Following an oral dose of ursodeoxycholic acid, both unconjugated and conjugated forms of the bile acid appeared in the serum of healthy individuals. (Auth.)

  10. Radioimmunoassay analysis of baculovirus granulins and polyhedrins

    International Nuclear Information System (INIS)

    Summers, M.D.; Hoops, P.

    1980-01-01

    Granulin and polyhedrin proteins were purified by preparative sodium dodecyl sulfate (SDS)-polyacrylamide gel electrophoresis from the baculoviruses Autographa californica, Rachiplusia ou, Heliothis zea, Heliothis armigera. Trichoplusia ni, and Spodoptera frugiperda. Antisera were raised against Autographa californica (Ac) polyhedrin and Trichoplusia ni (Tn) granulin and analyzed for homologous and heterologous immunoreactivity by immunodiffusion and radioimmunoassay (RIA). Ac polyhedrin and Tn granulin antisera recognized antigenic determinants on several baculovirus polyhedrin and granulin proteins even though the heterologous proteins had different immunoreactivities when compared by competition radioimmunoassay. Antigenic differences among granulin and polyhedrin proteins were also detected by altered slopes of the competition reaction curves. Antiserum raised against Ac polyhedrin which was purified in the presence of SDS was tested by competition RIA for its ability to detect and react with native polyhedrin produced in the infected TN-368 cells. Ac polyhedrin antiserum had similar if not identical ability to bind to native polyhedrin and to polyhedrin purified in the presence of SDS

  11. Anamnesis of the radioimmunoassay: A historical reminiscence

    Energy Technology Data Exchange (ETDEWEB)

    Kallee, E

    1984-01-27

    Anamnesis of the Radioimmunoassay - A Historical Reminiscence: Several requirements have to be met before the first radioimmunoassay of a proteohormone (i.e., insulin) could be developed. One of these requirements was that iodination ought not substantially impair the immunologic properties of the insulin molecule. Since the reversibility of antigen adsorption to antibodies is the most important basis of all immunoassays, the adsorptive behavior of proteins first had to be studied at extremely low protein concentrations. Only after these requirements had been investigated was direct electrophoretic detection of a nonprecipitating anti-hormone antibody possible by desorption of insulin on filter paper. Later, the inaccuracy of the species specificity of insulin-binding antibodies proved to be particularly useful for the determination of insulin in human sera.

  12. Radioimmunoassay of human Hageman factor (factor XII)

    International Nuclear Information System (INIS)

    Saito, H.; Ratnoff, O.D.; Pensky, J.

    1976-01-01

    A specific, sensitive, and reproducible radioimmunoassay for human Hageman factor (HF, factor XII) has been developed with purified human HF and monospecific rabbit antibody. Precise measurements of HF antigen were possible for concentrations as low as 0.1 percent of that in normal pooled plasma. A good correlation (correlation coefficient = 0.82) existed between the titers of HF measured by clot-promoting assays and radioimmunoassays among 42 normal adults. Confirming earlier studies, HF antigen was absent in Hageman trait plasma, but other congenital deficient plasmas, including those of individuals with Fletcher trait and Fitzgerald trait, contained normal amounts of HF antigen. HF antigen was reduced in the plasmas of patients with disseminated intravascular coagulation or advanced liver cirrhosis, but it was normal in those of patients with chronic renal failure or patients under treatment with warfarin. HF antigen was detected by this assay in plasmas of primates, but not detectable in plasmas of 11 nonprimate mammalian and one avian species

  13. Folic acid derivatives for use in radioimmunoassay

    International Nuclear Information System (INIS)

    Ali, A.

    1981-01-01

    The chemical preparation of two folic acid derivatives, labelled with 125 I or 131 I, is described for use in radioimmunoassay of folic acid and its metabolites in biological fluids such as blood serum. Labelled compounds of the present invention more closely resemble folic acid in that they have glutamic acid in the terminal position. Examples of the use of these compounds in three different assays are given. (U.K.)

  14. Significance and radioimmunoassay of gastric inhibitory polypeptide

    International Nuclear Information System (INIS)

    Zheng Ping; Zeng Minde; Yuan Jimin

    1995-01-01

    We have established the GIP Radioimmunoassay which has high sensitivity and specificity by labelling with iodogen and purified with HPLC. Using this method, the plasma GIP level was measured in 64 cases of which there are 10 normal individuals, 25 cases of diabetes and 29 cases of liver cirrhosis . The results showed that the plasma GIP level was significantly increased in patients with liver cirrhosis and correlated to degree of glucose tolerance damage

  15. Radioimmunoassay of ovine alpha-fetoprotein

    International Nuclear Information System (INIS)

    Lai, P.C.W.

    1978-01-01

    Highly purified ovine alpha-fetoprotein (AFP) was used both for radioisotope labelling and as the reference standard in the double antibody radioimmunoassay of ovine AFP. The sensitivity of the assay is 2 ng/ml which is about 8000 times more sensitive than radioimmunodiffusion assay. The assay is of sufficient sensitivity to quantitate AFP in normal adult sheep serum, pregnancy serum, amniotic fluid and fetal lamb serum. (Auth.)

  16. Status of radioimmunoassay services in the Philippines

    International Nuclear Information System (INIS)

    Valencia, I.G.; Bonoan, L.S.; Medina, V.F.O.

    1986-01-01

    This paper discusses the participation of the Philippines as a member state of the International Atomic Energy Agency (IAEA) in the Regional Cooperation Agreement (RCA) project on radioimmunoassay of thyroid related hormones in Asia and the Pacific. Seven of the twenty-three radioassay laboratories engaged in RIA work have signified their agreement to participate in the program. The proposed organization and function structure of the project, the projected RIA use and strategy to popularize use of RIA are given. (ELC)

  17. Radioimmunoassay of measles virus antibodies in SSPE

    International Nuclear Information System (INIS)

    Jankowski, M.A.; Gut, W.; Kantoch, M.

    1982-01-01

    A sensitive radioimmunoassay (RIA) was introduced for detecting measles virus IgG and IgM antibodies. The hyperimmune response to the measles virus could be demonstrated more accurately by RIA than by haemagglutination inhibition (HI). The ratio between RIA and HI antibody titres was decidedly higher in sera and cerebrospinal fluids of patients with subacute sclerosing panencephalitis than in those of other groups tested. (author)

  18. Radioimmunoassay to quantitatively measure cell surface immunoglobulins

    International Nuclear Information System (INIS)

    Krishman, E.C.; Jewell, W.R.

    1975-01-01

    A radioimmunoassay techniques developed to quantitatively measure the presence of immunoglobulins on the surface of cells, is described. The amount of immunoglobulins found on different tumor cells varied from 200 to 1140 ng/10 6 cells. Determination of immunoglobulins on the peripheral lymphocytes obtained from different cancer patients varied between 340 to 1040 ng/10 6 cells. Cultured tumor cells, on the other hand, were found to contain negligible quantities of human IgG [pt

  19. Radioimmunoassays - what is their diagnostic value

    International Nuclear Information System (INIS)

    Panitz, N.

    1983-01-01

    A selection is made of hormones and enzymes which are measurable by radioimmunoassay and their organ-specific function is described. Endocrine function tests together with the stimulating or suppressing substances, reaction in the organism and the examined regulation are listed. Non-radioactive immunological determination methods and the use of monoclonal antibodies in vitro and in vivo with ''tumor imaging'' are indicated. (orig.) [de

  20. Radioimmunoassay of parathyroid hormone: past and future

    International Nuclear Information System (INIS)

    Yalow, R.S.

    1986-01-01

    In this report on radioimmunoassay of parathyroid hormone (iPTH) it was shown that the rate of disappearance of iPTH from plasma differed markedly in patients with primary hyperthyroidism or those with uremia and secondary hyperparathyroidism and that for each patient the rate of disappearance depended on the antiserum used for assay. The heterogeneity of iPTH in plasma was soon rapidly confirmed in many laboratories. (Auth.)

  1. Qualitative determination of tubulin by radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Joniau, M [Louvain Univ. (Belgium). Interdisciplinary Research Centre; Brabander, M de [Janssen Pharmaceutica, Beerse (Belgium). Lab. of Oncology; Mey, J de [Brussels Univ. (Belgium). Medische Stichting Koningin Elisabeth; Hoebeke, J [Brussels Univ. (Belgium). Lab. of Biochemical Pathology

    1977-06-15

    The use of an antiserum specific for tubulin in cytochemical studies was described previously. Here a report is presented on its application in a radioimmunoassay for tubulin useful in the concentration range of 0.5 to 20 ..mu..g tubulin/ml. The advantages of this technique over the classical colchicine binding assay are discussed in terms of sensitivity and nonsusceptibility to the degree of polymerization and thermal denaturation of tubulin allowing its application to cell culture homogenates.

  2. Simultaneous radioimmunoassay for luteinizing hormone and prolactin

    International Nuclear Information System (INIS)

    Steele, M.K.; Deschepper, C.F.

    1985-01-01

    A combined radioimmunoassay (RIA) for the measurement of the anterior pituitary proteins luteinizing hormone (LH) and prolactin (PRL) is described and compared with individual RIAs for these hormones. The standard curves and the sample values for LH and PRL were identical when determined in a combined or in an individual RIA. This technique may prove useful to a number of laboratories where it is desirable to determine levels of more than one hormone in limited sample volumes

  3. Studies on the radioimmunoassay of thyroid hormones

    International Nuclear Information System (INIS)

    Kim, J.R.; Awh, O.D.; Park, K.B.; Kim, Y.S.

    1980-01-01

    To establish radioimmunoassay (RIA) systems of 3,5,3'-triiodo-L-thyronine (T 3 ) and thyroxine (T 4 ), various experiments such as 125 I labelling, antibody raising, preparation of hormone-free sera and efficient separations of the free hormones from those of antibody bound etc. were conducted. By optimizing many factors, assay systems were successfully established. Some detailed methodological aspects were described. (author)

  4. Human aldolase B subunit-specific radioimmunoassay

    International Nuclear Information System (INIS)

    Asaka, M.; Alpert, E.

    1983-01-01

    A radioimmunoassay was developed for the direct quantification of aldolase B in human serum and tissues. The method is a double-antibody radioimmunoassay technique using radioiodinated aldolase B homopolymer as ligand, chicken antibodies to aldolase B and rabbit antibodies to chicken IgG. This radioimmunoassay was shown to be specific for the aldolase B subunit, with no cross-reactivity with either human aldolase A subunit or homopolymeric human aldolase C (C 4 ). The lowest measurable amount by this method was 2 ng/ml. Aldolase B is predominantly found in normal liver tissue, with relatively-high aldolase B levels also observed in kidney. Aldolase B levels in the serum obtained from 11 normal subjects ranged from 23 to 38 ng/ml, with a mean of 28.5 +- 9.2 (S.D.) ng/ml. Almost all of patients with hepatitis had serum aldolase B levels greater than 30 ng/ml. In cancer patients, serum aldolase B was slightly elevated in patients with metastatic liver cancer and primary lever cell carcinoma, whereas no elevation of serum aldolase B was shown in patients without liver metastasis. (Auth.)

  5. The production of antibodies for radioimmunoassay

    International Nuclear Information System (INIS)

    Court, G.

    1975-01-01

    Three factors which affect the outcome of any immunisation schedule designed to produce antisera for radio-immunoassay, the antigen, the method of immunisation and the choice of animal are considered. Several factors concerning the nature of the antigen are dealt with, for example, the molecular size and immunogenicity of the antigen. It is noted that the larger polypeptide and proteins are sufficiently immunogenic to elicit a useful antibody response alone and that whilst substances with molecular weights of less than 2000 may produce a response alone they will probably produce a better one if they are conjugated (chemically coupled) to a much larger molecule. The method of immunisation is discussed including a consideration of the use of adjuvant and the route and timing of injections. It is noted that antisera showing the relevant properties for radio-immunoassay are rarely produced without emulsification of the immunogen in Freund's adjuvant although this is not an absolute requirement for antibody production. Data are presented comparing the intramuscular and multiple intradermal routes of injection. The results, however, fail to demonstrate any major advantage for either method although the latter may be more economical, producing high titre antisera with relatively small amounts of immunogen. Because of their convenience rabbits are generally the first choice of animal for raising antisera for radioimmunoassay although guinea pigs, chickens and sheep have been used successfully in many cases

  6. Radioimmunoassay of measles virus hemagglutinin protein G

    International Nuclear Information System (INIS)

    Lund, G.A.; Salmi, A.A.

    1982-01-01

    Guinea pig and rabbit antisera from animals immunized with purified measles virus hemagglutinin (G) protein were used to establish a solid-phase four-layer radioimmunoassay for quantitative measurement of the G protein. The sensitivity of the assay was 2 ng of purified G protein, and 200 μg of protein from uninfected Vero cells neither decreased the sensitivity nor reacted non-specifically in the assay. Radioimmunoassay standard dose-response curves were established and unknown values interpolated from these using the logit program of a desktop computer. Using this procedure, a measles virus growth curve in infected Vero cells was determined by measurement of G protein production. Under these same conditions, hemagglutination was not sensitive enough to detect early hemagglutinin production. Viral antigens in canine distemper virus, Newcastle disease virus, parainfluenza viruses 1-4, simian virus 5, and respiratory syncytial virus-infected cell lysates did not cross-react in the radioimmunoassay. A small degree of cross-reactivity was detected with mumps viral antigens, both with Vero cell-derived (wild-type strain) and egg-derived (Enders strain) purified virus preparations and with a cell lysate antigen prepared from wild-type mumps virus-infected Vero cells. (Auth.)

  7. Radioimmunoassay of measles virus hemagglutinin protein G

    Energy Technology Data Exchange (ETDEWEB)

    Lund, G A; Salmi, A A [Turku Univ. (Finland)

    1982-08-01

    Guinea pig and rabbit antisera from animals immunized with purified measles virus hemagglutinin (G) protein were used to establish a solid-phase four-layer radioimmunoassay for quantitative measurement of the G protein. The sensitivity of the assay was 2 ng of purified G protein, and 200 ..mu..g of protein from uninfected Vero cells neither decreased the sensitivity nor reacted non-specifically in the assay. Radioimmunoassay standard dose-response curves were established and unknown values interpolated from these using the logit program of a desktop computer. Using this procedure, a measles virus growth curve in infected Vero cells was determined by measurement of G protein production. Under these same conditions, hemagglutination was not sensitive enough to detect early hemagglutinin production. Viral antigens in canine distemper virus, Newcastle disease virus, parainfluenza viruses 1-4, simian virus 5, and respiratory syncytial virus-infected cell lysates did not cross-react in the radioimmunoassay. A small degree of cross-reactivity was detected with mumps viral antigens, both with Vero cell-derived (wild-type strain) and egg-derived (Enders strain) purified virus preparations and with a cell lysate antigen prepared from wild-type mumps virus-infected Vero cells.

  8. Experimental formability analysis of bondal sandwich sheet

    Science.gov (United States)

    Kami, Abdolvahed; Banabic, Dorel

    2018-05-01

    Metal/polymer/metal sandwich sheets have recently attracted the interests of industries like automotive industry. These sandwich sheets have superior properties over single-layer metallic sheets including good sound and vibration damping and light weight. However, the formability of these sandwich sheets should be enhanced which requires more research. In this paper, the formability of Bondal sheet (DC06/viscoelastic polymer/DC06 sandwich sheet) was studied through different types of experiments. The mechanical properties of Bondal were determined by uniaxial tensile tests. Hemispherical punch stretching and hydraulic bulge tests were carried out to determine the forming limit diagram (FLD) of Bondal. Furthermore, cylindrical and square cup drawing tests were performed in dry and oil lubricated conditions. These tests were conducted at different blank holding forces (BHFs). An interesting observation about Bondal sheet deep drawing was obtaining of higher drawing depths at dry condition in comparison with oil-lubricated condition.

  9. Natural fabric sandwich laminate composites: development and ...

    Indian Academy of Sciences (India)

    3Department of Production Technology, MIT Campus, Anna University, Chennai 600044, India. MS received ... In this work, eco-friendly natural fabric sandwich laminate (NFSL) composites are formulated using ... and eco-friendly quality [22].

  10. Adhesion aspects of polyurethane foam sandwich panels.

    OpenAIRE

    Ng, Simon L.

    2016-01-01

    Sandwich panels, polyurethane foam sandwiched between two sheets of steel, form the walls and roofs in the construction of buildings. ArcelorMittal is a manufacturer of the steel as well as these finished panels. For this project they combined with a supplier of the polyurethane foams, Huntsman Polyurethanes, to joint-fund a research project investigating the fundamental mechanisms of adhesion, as well as the causes of failures in the product which manifests primarily in two different ways...

  11. Solid phase separation technique for use in radioimmunoassays

    International Nuclear Information System (INIS)

    Tu, J.I.

    1979-01-01

    A radioimmunoassay procedure, and article of manufacture for carrying out that procedure, are disclosed herein. The solid phase separation technique utilized in the radioimmunoassay of this invention utilizes a test tube, the internal surface of which has been coated with two antibody layers

  12. Quality control of radioiodinated gastrin for radioimmunoassay

    International Nuclear Information System (INIS)

    Ginabreda, M.G.P.; Borghi, V.C.; Bettarello, A.

    1988-07-01

    Radioiodinated human gastrin has been prepared at IPEN laboratory for radioimmunoassay use. This work developed the quality control of this tracer analyzing parameters of the labelling reaction, chromatographic purification and radioimmunoassay. The radioiodination yield obtained in five experiments was reproducible and similar when analyzed on 7% polyaraylamide gel eletrophoresis - PAGE - (mean + - SD of 51.70 + - 10.76%) and by1 25 I incorporation checked through thrichloroacetic acid precipitation - TCA - (57-36 + - 9.69%). Similary, after purification the labelled gastrin revaled high and reproducible purity degree when submitted to PAGE (96.57 + - 1.06%) and CA (94.82 + - 4.20%) analysis. The respective specific activities varied from 62 to 307 uCi/ug, being determined by the self-displacement method, which is based on the immunoactivity of the tracer. In this way, the antibody titers required to bind 50% of the tracer ranged from 1:32.000 to 1:180.000. Consequently, the respective doses producing 50% fall in the maximum response of the radioimmunoassays ranged from 155.0 to 24.0 pmol/1, but remained unchanged for each tracer even after three months of its preparations. The tracers presented very low non-specific binding values (1.78 + - 0.79%), stablespecific binding values (46.49 + - 5.65%) and a good between-assay precision, evaluated by an internal quality control sample (25.71 + - 4.30%) with coefficient of variation of 16.74%). The PAGE analysis of the unlabeled gastrin used in the first and last radioiodination revealed an unique and unaltered component, confirming the quality of the tracers. (author) [pt

  13. A linear graph for digoxin radioimmunoassay

    International Nuclear Information System (INIS)

    Smith, S.E.; Richter, A.

    1975-01-01

    The determination of drug or hormone concentrations by radio-immunoassay involves interpolation of values for radioisotope counts within standard curves, a technique which requires some dexterity in curve drawing and which results in some inaccuracy in practice. Most of the procedures designed to overcome these difficulties are complex and time-consuming. In radioimmunoassays involving saturation of the antibody-binding sites a special case exists in that the bound radioactivity is directly proportional to the specific activity of the ligand in the system. Thus a graph of the ratio of radioactivity bound in the absence to that in the presence of added non-radioactive ligand is linear against the concentration of added ligand (Hales,C.N., and Randle, P.J., 1963, Biochem. J., vol. 88, 137). A description is given of a simple and convenient modification of their method, and its application to the routine clinical determination of digoxin using a commercial kit (Lanoxitest β digoxin radioimmunoassay kit, Wellcome Reagents Ltd.). Specially constructed graph paper, which yields linearity with standard solutions, was designed so that it could be used directly without data transmission. The specific activity function appears as the upper arithmetical horizontal scale; corresponding values of the concentration of non-radioactive ligand in the solution added were individually calculated and appear on the lower scale opposite the appropriate values of the upper scale. The linearity of the graphs obtained confirmed that binding of digoxin was approximately constant through the range of clinical concentrations tested (0.5 to 8ng/ml), although binding declined slightly at higher concentrations. (U.K.)

  14. Radioimmunoassay of nortestosterone and related steroids

    International Nuclear Information System (INIS)

    Hampl, R.; Starka, L.; Picha, J.; Chundela, B.

    1979-01-01

    A radioimmunoassay of nortestosterone and related steroids, including its principal metabolites, is described and evaluated. Antisera against nortestosterone-17β-hemisuccinate- and nortestosterone-3-carboxymethyloxime-bovine serum albumin were raised in goats. By using a mixture of such antisera with different selectivity, the cross-reactions of several naturally occuring steroids can be reduced. The method can be applied for the detection of nortestosterone in both unprocessed or hydrolyzed urine extracts and also in plasma. It has been used as a screening test for anabolics in doping control. (orig.) [de

  15. Radioimmunoassay for thyroid-stimulating hormone (TSH)

    International Nuclear Information System (INIS)

    Blakemore, J.I.; Lewin, N.; Burgett, M.W.

    1978-01-01

    This invention provides a method for the radioimmunoassay of thyroid-stimulating hormone which utilizes a rapid and convenient version of a double antibody procedure. Highly purified second antibody is bound, by means of covalent bonds, to hydrolyzed polyacrylamide particles to produce a two-phase system. The solid phase comprises immobilized second antibody bound to the reaction product of labeled and unlabeled thyroid-stimulating hormone with the first antibody (first antibody-antigen complex) and the liquid phase comprises free (unbound) labeled and unlabeled thyroid-stimulating hormone. The two phases are separated and the radioactivity of either phase is measured

  16. Application of radioimmunoassay in food industry

    International Nuclear Information System (INIS)

    Rauch, P.; Fukal, L.; Kas, J.

    1983-01-01

    Radioimmunoassay can be used in evaluating the quality and wholesomeness of food. The method is advantageous for its speed, specificity, high sensitivity, relative ease of performance, and the possibility of performing a great number of parallel determinations using automation and computer evaluation. It can be used in determining macromolecules of proteins and enzymes. The determination of papain in beer is shown by way of example. Other possibilities of the method include: the determination of microbial toxins of the peptide nature, vitamins, hormones, antibiotics, pesticides and their residues, alkaloids, and carcinogenic materials. (M.D.)

  17. Aflatoxin B1 use in radioimmunoassay

    International Nuclear Information System (INIS)

    Liu Yinkun; Zhang Xiaying; Chen Ruiqun; Gu Tianjue

    1987-01-01

    Antibodies against Aflatoxin B 1 (AFB 1 ) were obtained after multiple-site injections of bovine serum albumin-AFB 1 conjugate into rabbits. The greatest specific binding effciency of antibody for AFB 1 is 70∼80%. The sensitivity of radioimmunoassay (RIA) for AFB 1 is between 0.46∼2.3 ng. The retrievel rate of AFB 1 by RIA from intentionally contaminated serum and rice is between 70∼80%. Detailed methods for the preparation of conjugate, immune serum, and methods for antibody titer determination are described

  18. Radioimmunoassay of serum myoglobin in neuromuscular diseases

    Energy Technology Data Exchange (ETDEWEB)

    Askmark, H; Osterman, P O; Roxin, L E; Venge, P [University Hospital, Uppsala (Sweden)

    1981-01-01

    Radioimmunoassay of serum myoglobin was performed in 85 patients with muscular symptoms. Elevated levels were found in 93% of patients with myogenic myopathy, in 54% with myasthenia gravis and in 50% with neurogenic myopathy. All 11 patients with polymyositis had elevated myoglobin concentrations. In six of seven patients with polymyositis, who were followed up with repeated determinations, a clear relationship between myoglobin levels and clinical course was found. In general serum myoglobin seemed to be a more sensitive indicator of muscle disease than creatine kinase.

  19. Determination of carbofuran in water by radioimmunoassay

    International Nuclear Information System (INIS)

    Zhu Guonian; Wu Huiming; Yang Ting; Hu Xiuqing

    2004-01-01

    A competitive radioimmunoassay (RIA) method was established to detect carbofuran in water samples. Compared with traditional analytical methods RIA provided a easy procedure with higher sensitivity. The detective limitation of RIA for carbofuran was proved to be 0.175 ng/ml. A study was performed to test validation of the RIA. In this study carbofuran residues in water samples were detected simultaneously by RIA and by high performance liquid chromatograph (HPLC). The linear correlation coefficient of the test results was measure to be 0.9985. (authors)

  20. Radioimmunoassay. A revolution in the analytic procedure

    Energy Technology Data Exchange (ETDEWEB)

    Strecker, H; Eckert, H G [Farbwerke Hoechst A.G., Frankfurt am Main (Germany, F.R.). Radiochemisches Lab.

    1978-04-01

    Radioimmunoassay is an analytic method which combines the sensitivity of radioactive measurement and the specificity of the antigen-antibody reaction Substances down to a concentration of some picograms per ml serum (or biological material) can be measured in the presence of a millionfold excess of otherwise interfering substances. The method is easy to carry out (test tube chemistry). The main field of application at the moment is in endocrinology; further possibilities of application are in pharmaceutical research, environmental protection, forensic medicine, and for general analytic purposes. Radioactive sources are used only in vitro in the nanocurie range, i.e. radiation exposure is negligible.

  1. Transfer of estradiol to human milk. [Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S.; Nygren, K.G.; Johansson, E.D.B.

    1978-11-15

    A radioimmunoassay for the measurement of estradiol in human milk is evaluated. The detection limit was found to be 25 pg of estradiol per milliliter of milk. In milk samples collected from four lactating women during three to four months and from one pregnant and lactating woman, the concentration of estradiol was found to be below the detection limit of the assay. When six lactating women were given vaginal suppositories containing 50 or 100 mg of estradiol, it was possible to estimate the estradiol concentration in milk. A ratio of transfer of estradiol from plasma to milk during physiologic conditions is calculated to be less than 100 : 10.

  2. Radioimmunoassay in the diagnosis of fascioliasis

    Energy Technology Data Exchange (ETDEWEB)

    Tomanek, J; Willomitzer, J; Chroustova, E [Veterinary Research Inst., Brno (Czechoslovakia)

    1978-06-30

    The objective of the study was to develop a sensitive and specific radioimmunoassay (RIA) method for the diagnosis of F. hepatica infection that would be convenient to use in examining large numbers of samples. The main problem was the preparation of a suitable antigen or specific fraction, since the crude extract of adult Fasciola hepatica is a heterogeneous mixture of somatic, metabolic and host substances with possible nonspecific antigenic properties. The antigen was a protein fraction separated from crude extract of adult F. hepatica by gel filtration and labelled with /sup 125/iodine.

  3. Solid phase double-antibody radioimmunoassay procedure

    International Nuclear Information System (INIS)

    Niswender, G.D.

    1977-01-01

    The present invention is concerned with the radioimmunoassay (RIA) procedure for assaying body fluid content of an antigenic substance which may either be an antigen itself or a hapten capable of being converted, such as by means of reaction with a protein, to an antigenic material. The present invention is concerned with a novel and improved modification of a double-antibody RIA technique in which there is a first antibody that is specific to the antigenic substance suspected to be present in a body fluid from which the assay is intended. The second antibody, however, is not specific to the antigenic substance or analyte, but is an antibody against the first antibody

  4. Radioimmunoassay procedure using a stabilized complex

    International Nuclear Information System (INIS)

    Sultanian, I.V.; Irani, J.H.

    1978-01-01

    An improved radioimmunoassay procedure involves the use of a stabilized complex of labelled antigen and antibody which has an extended shelf life as compared to the same complex absent the stabilizers. Since the time needed to incubate the mixture of labelled antigen and antibody is eliminated, the time for completing the assay is considerably shortened and simplified. The components for carrying out the procedure are packaged in a kit basically including standard antigen for generation of a standard curve, a stabilized labelled antigen-antibody complex and reference serum, if used. A plurality of stabilizers are used in the complex to provide a shelf life of six weeks or more. 10 claims

  5. Radioimmunoassay of serum myoglobin in neuromuscular diseases

    International Nuclear Information System (INIS)

    Askmark, H.; Osterman, P.O.; Roxin, L.-E.; Venge, P.

    1981-01-01

    Radioimmunoassay of serum myoglobin was performed in 85 patients with muscular symptoms. Elevated levels were found in 93% of patients with myogenic myopathy, in 54% with myasthenia gravis and in 50% with neurogenic myopathy. All 11 patients with polymyositis had elevated myoglobin concentrations. In six of seven patients with polymyositis, who were followed up with repeated determinations, a clear relationship between myoglobin levels and clinical course was found. In general serum myoglobin seemed to be a more sensitive indicator of muscle disease than creatine kinase. (author)

  6. Radioimmunoassay in the diagnosis of fascioliasis

    International Nuclear Information System (INIS)

    Tomanek, J.; Willomitzer, J.; Chroustova, E.

    1978-01-01

    The objective of the study was to develop a sensitive and specific radioimmunoassay (RIA) method for the diagnosis of F. hepatica infection that would be convenient to use in examining large numbers of samples. The main problem was the preparation of a suitable antigen or specific fraction, since the crude extract of adult Fasciola hepatica is a heterogeneous mixture of somatic, metabolic and host substances with possible nonspecific antigenic properties. The antigen was a protein fraction separated from crude extract of adult F. hepatica by gel filtration and labelled with 125 iodine. (T.I.)

  7. Radioimmunoassay of sodium cromoglycate in human plasma

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K; Gardner, J J; Lockley, W J.S.; Preston, J R; Wilkinson, D J [Fisons plc, Loughborough (UK). Pharmaceutical Div.

    1983-01-01

    A sensitive radioimmunoassay method for sodium cromoglycate in human plasma is described. The lowest quantifiable concentration of sodium cromoglycate is 0.93 nmol/l when 0.1 ml plasma samples are analysed. The range of the method is limited; both 0.01 and 0.1 ml volumes of plasma must be analysed to encompass the concentration range 0.93-139 nmol/l which may be encountered in plasma samples from patients and human volunteers. The method is specific for sodium cromoglycate as indicated by a low cross-reactivity of the anti-cromoglycate antiserum with a number of drugs.

  8. HLA-DR typing by radioimmunoassay

    International Nuclear Information System (INIS)

    Tosi, R.; Tanigaki, N.; Centis, D.; Rossi, P.L.; Alfano, G.; Ferrara, G.B.; Pressman, D.

    1980-01-01

    A radioimmunoassay procedure is described by which peripheral blood lymphocytes can be typed for HLA-DR specificities. The major advantages of this method are the following: simple and reproducible procedure, no need for B lymphocyte separation, no need for optimal viability, and no need for preabsorption of antisera with platelets. This method will find an application in the genetic and biochemical analysis of the HLA complex, and in the clinical tests of Ia antigens for diagnostic or prognostic purposes and in retrospective transplant studies

  9. Development of a radioimmunoassay for papain

    International Nuclear Information System (INIS)

    Rauch, P.; Fukal, L.; Marek, M.; Strejcek, F.; Kas, J.

    1984-01-01

    Various well-tried radioimmunoassay (RIA) techniques were compared for the quantitation of papain. The evaluation of individual assays was performed by logit-log analysis. The most compatible analytical steps were combined in order to obtain the optimal analytical conditions of the assay. The preferred RIA involves papain labelling with lactoperoxidase, a double antibody method as the separation step and a 24 h incubation period at 2 0 C. It permits the detection of 16 ng of papain per tube. In contrast, a method using immobilized antibody was satisfactory for rapid quantitation of papain with quite acceptable accuracy. (Auth.)

  10. Energy Dissipation in Sandwich Structures During Axial Compression

    DEFF Research Database (Denmark)

    Urban, Jesper

    2002-01-01

    The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full-scale structu......The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full...

  11. Vibro-acoustics of lightweight sandwich structures

    CERN Document Server

    Lu, Tianjian

    2014-01-01

    Vibro-Acoustics of Lightweight Sandwich Structures introduces the study of the coupled vibration and acoustic behavior of lightweight sandwich structures in response to harmonic force and sound pressure. This book focuses on the theoretical modeling and experimental investigation of lightweight sandwich structures in order to provide a predictive framework for vibro-acoustic characteristics of typical engineering structures. Furthermore, by developing solution tools, it concentrates on the influence of key systematic parameters leading to effective guidance for optimal structure design toward lightweight, high-stiffness and superior sound insulation capability. This book is intended for researchers, scientists, engineers and graduate students in mechanical engineering especially in structural mechanics, mechanics and acoustics. Fengxian Xin and Tianjian Lu both work at the School of Aerospace, Xi’an Jiaotong University.

  12. Behavior of sandwich panels in a fire

    Science.gov (United States)

    Chelekova, Eugenia

    2018-03-01

    For the last decades there emerged a vast number of buildings and structures erected with the use of sandwich panels. The field of application for this construction material is manifold, especially in the construction of fire and explosion hazardous buildings. In advanced evacu-ation time calculation methods the coefficient of heat losses is defined with dire regard to fire load features, but without account to thermal and physical characteristics of building envelopes, or, to be exact, it is defined for brick and concrete walls with gross heat capacity. That is why the application of the heat loss coefficient expression obtained for buildings of sandwich panels is impossible because of different heat capacity of these panels from the heat capacities of brick and concrete building envelopes. The article conducts an analysis and calculation of the heal loss coefficient for buildings and structures of three layer sandwich panels as building envelopes.

  13. Radioimmunoassay of bleomycin in plasma and urine

    International Nuclear Information System (INIS)

    Teale, J.D.; Clough, J.M.; Marks, V.

    1977-01-01

    Antibodies to bleomycin were raised by immunization of sheep and rabbits with bleomycin-albumin conjugates. The combination of a high-titre, high-avidity sheep antiserum and iodinated bleomycin produced a radioimmunoassay sensitive to 8 ng of bleomycin per ml of plasma or urine. Untreated specimens (100 μl) of plasma or urine could be added directly to the assay tubes. The anti-serum was specific for bleomycin and showed no cross-reaction with other anti-cancer agents used in combination chemotherapy. Over a concentration range of 20 to 100 ng/ml. recovery of bleomycin from plasma was 110% and from urine, 93%. Repeated assay of plasma samples showed a decrease in bleomycin levels unless the samples were kept at 4 0 C or below. Assay of bleomycin levels in plasma and urine from patients under treatment with bleomycin showed similarities with results reported using a microbiological assay. The radioimmunoassay offers a more reliable, rapid and sensitive method for the measurement of bleomycin. (author)

  14. Radioimmunoassay in the diagnosis of arterial hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Slavnov, V N; Olejnik, V A; Yakovlev, A A; Yugrinov, O G; Markov, V V [Kievskij Nauchno-Issledovatel' skij Inst. Ehndokrinologii i Obmena Veshchestv (Ukrainian SSR)

    1984-11-01

    The paper is concerned with the results of a study of the aldosterone concentration and renin activity, the general level of catecholamines and their fractions in the peripheral blood and blood taken at selective venography from the vena cava inferior, renal and adrenal veins of 108 patients with hypertension, aldosteroma and idiopathic hyperaldosteronism, adrenal and extraadrenal pheochromocytoma, renovascular and renoparenchymatous arterial hypertension. The aldosterone concentration and renin activity were determined with radioimmunoassay, and the general content of catecholamines and their fractions with a radioenzymatic method using standard kits. It has been shown that the radioimmunoassay to determine the aldosterone concentration and renin activity makes possible differential diagnosis of hypertension, aldosteroma, idiopathic and secondary hyperaldosteronism. A considerable increase in the blood plasma renin activity on the affected side was revealed in the patients with renovascular hypertension, and in renoparenchymatous hypertension it was equal in both renal veins. The study of the total content of catecholamines and their fractions in the blood from different parts of the venous system can be used for topical diagnosis of adrenal and extraadrenal pheochromocytoma.

  15. Radioimmunoassay in the diagnosis of arterial hypertension

    International Nuclear Information System (INIS)

    Slavnov, V.N.; Olejnik, V.A.; Yakovlev, A.A.; Yugrinov, O.G.; Markov, V.V.

    1984-01-01

    The paper is concerned with the results of a study of the aldosterone concentration and renin activity, the general level of catecholamines and their fractions in the peripheral blood and blood taken at selective venography from the vena cava inferior, renal and adrenal veins of 108 patients with hypertension, aldosteroma and idiopathic hyperaldosteronism, adrenal and extraadrenal pheochromocytoma, renovascular and renoparenchymatous arterial hypertension. The aldosterone concentration and renin activity were determined with radioimmunoassay, and the general content of catecholamines and their fractions with a radioenzymatic method using standard kits. It has been shown that the radioimmunoassay to determine the aldosterone concentration and renin activity makes it possible to resort to differential diagnosis of hypertension, aldosteroma, idiopathic and secondary hyperaldosteronism. A considerable increase in the blood plasma renin activity on the affected side was revealed in the patients with renovascular hypertension, and in renoparenchymatous hypertension it was equal in both renal veins. The study of the total content of catecholamines and their fractions in the blood from different parts of the venous system can be used for topical diagnosis of adrenal and extraadrenal pheochromocytoma

  16. Radioimmunoassay for hepatitis B core antigen

    International Nuclear Information System (INIS)

    Sagnelli, E.; Pereira, C.; Triolo, G.; Vernace, S.; Paronetto, F.

    1982-01-01

    Serum hepatitis B core antigen (HBcAg) is an important marker of hepatitis B virus replication. We describe an easy, sensitive radioimmunoassay for determination of HBcAg in detergent-treated serum pellets containing Dane particles. Components of a commercial kit for anticore determination are used, and HBcAG is measured by competitive inhibition of binding of 125 I-labeled antibodies to HBcAg with HBcAg-coated beads. We assayed for HBcAG in the sera of 49 patients with hepatitis B surface antigen (HBsAg)-positive chronic hepatitis, 50 patients with HBsAg-negative chronic hepatitis, and 30 healthy volunteers. HBcAg was detected in 41% of patients with HBsAg-positive chronic hepatitis but not in patients with HBsAg-negative chronic hepatitis. Hepatitis Be antigen (an antigen closely associated with the core of Dane particles) determined in the same sera by radioimmunoassay, was not detected in 50% of HBcAg-positive sera

  17. Human C-peptide. Pt. 1. Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Beischer, W; Keller, L; Maas, M; Schiefer, E; Pfeiffer, E F [Ulm Univ. (Germany, F.R.). Abt. Innere Medizin, Endokrinologie und Stoffwechsel

    1976-08-01

    Synthetic human C-peptide bearing a tyrosine group at its amino end is labelled with /sup 125/iodine using chloramin T or hydrogen peroxide and lactoperoxidase. The results of the two methods are compared. Antiserum to synthetic human C-peptide (without tyrosine), which was partially coupled to rabbit albumin, is raised in guinea pigs and goats. Goats show to be superior to guinea pips concerning antibody production. The so-called 'hook effect' phenomenon is observed when setting up the standard curves for the radioimmunoassay. Monotonically decreasing standard curves are obtained on dilution of antiserum with a high antibody titer which was produced by repeated immunization in goats. Free C-peptide and C-peptide bound to antiserum are separated using the anion exchange resin amberlite. Using this separation technique we excluded unspecific binding of labelled C-peptide to protein fractions in serum of diabetics. The sensitivity of our radioimmunoassay is approx. 0.3 ng C-peptide/ml serum. Intra- and interassay variability are below 10%. Human proinsulin is the only substance found to crossreact with the antiserum.

  18. Buckling Analysis of Edge Cracked Sandwich Plate

    Directory of Open Access Journals (Sweden)

    Rasha Mohammed Hussein

    2016-07-01

    Full Text Available This work presents mainly the buckling load of sandwich plates with or without crack for different cases. The buckling loads are analyzed experimentally and numerically by using ANSYS 15. The experimental investigation was to fabricate the cracked sandwich plate from stainless steel and PVC to find mechanical properties of stainless steel and PVC such as young modulus. The buckling load for different aspect ratio, crack length, cracked location and plate without crack found. The experimental results were compared with that found from ANSYS program. Present of crack is decreased the buckling load and that depends on crack size, crack location and aspect ratio.

  19. AA, sandwich line with magnetic horn

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    The magnetic horn, focusing the antiprotons emanating from the target, was affixed to a sandwich line through which the 150 kA pulses were supplied. Expecting to have to change from time to time the fragile horn (inner conductor only 0.7 mm thick), the assembly was designed for quick exchange. At the lower end of the sandwich line we see the connectors for the high-current cables, at the upper end the magnet horn. It has just been lifted from the V-supports which held it aligned downstream of the target. Continue with 8010293.

  20. Buckling driven debonding in sandwich columns

    DEFF Research Database (Denmark)

    Østergaard, Rasmus Christian

    2008-01-01

    results from two mechanisms: (a) interaction of local debond buckling and global buckling and (b) the development of a damaged zone at the debond crack tip. Based on the pronounced imperfection sensitivity, the author predicts that an experimental measurement of the strength of sandwich structures may......A compression loaded sandwich column that contains a debond is analyzed using a geometrically non-linear finite element model. The model includes a cohesive zone along one face sheet/core interface whereby the debond can extend by interface crack growth. Two geometrical imperfections are introduced...

  1. Long sandwich modules for photon veto detectors

    International Nuclear Information System (INIS)

    Yershov, N.; Khabibullin, M.; Kudenko, Yu.; Littenberg, L.; Mayatski, V.; Mineev, O.

    2005-01-01

    Long lead-scintillator sandwich modules developed for the BNL experiment KOPIO are described. The individual 4 m long module consists of 15 layers of 7 mm thick extruded scintillator and 15 layers of 1 mm lead absorber. Readout is implemented via WLS fibers glued into grooves in a scintillator with 7 mm spacing and viewed from both ends by the phototubes. Time resolution of 300 ps for cosmic MIPs was obtained. Light output stability monitored for 2 years shows no degradation beyond the measurement errors. A 4 m long C-bent sandwich module was also manufactured and tested

  2. Steroid radioimmunoassay: contribution of standards to blank values, ch. 4

    International Nuclear Information System (INIS)

    Froelich, M.; Termorshuizen, W.; Kenter, E.; Molenaar, A.J.

    1977-01-01

    The sensitivity of the radioimmunoassay of steroids is considerably reduced by high blank values which may be derived in part from co-chromatographed standards. Blank levels approach the detection limit of the radioimmunoassay of aldosterone, testosterone and androstenedione when 10,000 dpm (30-35 pg) labelled steroids are used as reference standard. When 20 μg aldosterone, testosterone, or androstenedione is used as standard, blank levels of up to 12,800 pg were measured in the radioimmunoassay. Application of the standards on a separate strip does not improve the results. From the experiments it appeared that contamination took place by transport by the solvent

  3. A competitive-inhibiton radioimmunoassay for influenza virus envelope antigens

    International Nuclear Information System (INIS)

    Russ, G.; Styk, B.; Vareckova, E.; Polakova, K.

    1976-01-01

    A double-antibody competitive-inhibition radioimmunoassay for influenza virus envelope antigens is described. A viral antigen preparation from influenza A virus recombinant MRC11 [antigenically identical to A/Port Chalmers/1/73 (H3N2)] consisting of haemagglutinin and neuraminidase was labelled with radioiodine. Rabbit antisera were allowed to react with the labelled antigen and the resultant antigen-antibody complexes were precipitated with the appropriate antiglobulin. The competitive-inhibition radioimmunoassay very sensitively elucidated differences even among closely related influenza virus strains. Attempts have been made to eliminate neuraminidase from radioimmunoprecipitation to obtain a competitive-inhibition radioimmunoassay system for haemagglutinin alone. (author)

  4. Radioiodinated derivatives for steroid radioimmunoassay. Application to the radioimmunoassay of cortisol

    International Nuclear Information System (INIS)

    Gomez-Sanchez, C.; Milewich, L.; Holland, O.B.

    1977-01-01

    Gamma-emitting steroid tracers for use in the radioimmunoassay of steroids have a number of advantages over the more common tritiated tracers. The steroid derivatives aldosterone-3-(p-hydroxybenzoyl) hydrazone, aldosterone-3-(p-hydroxyphenylpropionyl)hydrazone, deoxycorticosterone-3-(p-hydroxyphenylpropionyl)hydrazone, and cortisol-3-(p-hydroxyphenylpropionyl)hydrazone were synthesized by a one-step procedure and iodinated ([ 125 I]). To illustrate the usefulness of these derivatives, we describe the details of a cortisol radioimmunoassay. The use of the radioiodinated tracer appeared to increase the specificity of the antigen-antibody reaction when compared with [ 3 H]cortisol. The methodology involved in the preparation of the steroid derivatives described above can be extended to other 3-oxo-4-ene-containing steroids, with the advantages of economy, simplicity, and versatility

  5. Compressive properties of sandwiches with functionally graded

    Indian Academy of Sciences (India)

    The compressive behaviour of a new class of sandwich composite made up of jute fiber reinforced epoxy skins and piece-wise linear fly ash reinforced functionally graded (FG) rubber core is investigated in flat-wise mode. FG samples are prepared using conventional casting technique. Presence of gradation is quantified ...

  6. X-joints in composite sandwich panels

    NARCIS (Netherlands)

    Vredeveldt, A.W.; Janssen, G.Th.M.

    1998-01-01

    The small structural weight of fast large ships such as fast mono hulls or catamaran type of ships is of extreme importance to their success. One possible light weight structural solution is the sandwich panel with fibre reinforced laminates and a balsa, honeycomb or foam core. A severe obstacle for

  7. AA, sandwich line with magnetic horn

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    Continuation from 8010293: Finally, the sandwich line with the horn is placed on the ground, for the horn to be inspected and, if needed, exchanged for a new one. The whole procedure was trained with several members of the AA team, for quick and safe handling, and to share the radiation dose amongst them.

  8. Report on the national seminar on radioimmunoassays

    International Nuclear Information System (INIS)

    1979-01-01

    Deliberations of the National Seminar on Radioimmunoassays (RIA) held at Bombay during 16-20 January 1978 are reported. Various aspects of the application of RIA techniques in India were discussed in the seminar. They included the basic requirements of RIA in India, the state-of-the-art of RIA in India, radiation protection in RIA, quality control of RIA, usefulness and limitations of RIA in clinical diagnosis and use of RIA in tropical infectious diseases. Difficulties encountered in the practice of RIA techniques in India were found to be mainly related to availability of 125 I, RIA kits, antisera and hormones. The need for establishing a centralised assay service for RIA was examined and it was concluded that such a step would be premature in the present situation. Recommendations made and guidelines spelt out deal with resources for RIA, research, referral assay service, training and information exchange and dissemination. (M.G.B.)

  9. Radioimmunoassay for thyroid stimulating hormone (TSH)

    International Nuclear Information System (INIS)

    1980-01-01

    An improved double antibody radioimmunoassay method is described for the determination of thyroid stimulating hormone (TSH) in biological and other fluids. Highly purified second antibody is immobilised on to hydrophilic, hydrolyzed polyacrylamide particles of a suspendable size to form a solid phase second antibody reagent. The immobilised second antibody reagent is used to precipitate the reaction product of the first antibody with labelled and unlabelled thyroid stimulating hormone (TSH-anti-TSH-complex) so as to produce a two-phase system which permits rapid and efficient separation of bound TSH in the solid phase from free TSH in the liquid phase. Details of the preparation of this novel second antibody-polyacrylamide reagent and of the assay procedure for human TSH are described. (U.K.)

  10. Radioimmunoassay of luteinizing hormone in hypothyroidism

    International Nuclear Information System (INIS)

    Sobieszczyk, S.

    1975-01-01

    Radioimmunoassay of luteinizing hormone was performed in 18 women with primary hypothyroidism and 15 women with secondary hypothyroidism. The results of determinations were compared with LH values found in healthy women at reproductive age and after menopause. It was observed that in primary hypothyroidism the level of LH is normal, in young women it was from 6 to 25 m IU/ml, while in the postmenopausal period it increased to 70 to 200 m IU/ml. In secondary hypothyroidism due to pituitary hypofunction the LH level is undetectable or lies in the range of lowest values observed in healthy subjects, not exceeding 8 m IU/ml. Determinations of serum LH may be useful for differential diagnosis of primary and secondary hypothyroidism. (author)

  11. A radioimmunoassay for neurotensin in human plasma

    International Nuclear Information System (INIS)

    Blackburn, A.M.; Bloom, S.R.

    1979-01-01

    A radioimmunoassay was developed for detecting the neurotensin peptide in human plasma. The plasma was specific for neurotensin as no cross-reaction was found with any of the other gut hormones tested. Changes of 5 pmol/l could be detected with 95% confidence. Neurotensin was unstable in both blood and plasma but considerable protection was afforded by addition of aprotinin, rapid separation of plasma and immediate deep freezing. Neurotensin-like immunoreactivity was detected in human plasma in both a small and large molecular form. The mean fasting level of plasma neurotensin-like immunoreactivity in 36 healthy volunteers was 29 +- 3 pmol/l. A significant increment of 27 +- 8 pmol/l plasma neurotensin immunoreactivity was detected after a large meal in nine healthy men. In view of the present results in man and also of neurotensin's potent pharmacological actions in experimental animals, neurotensin appears to fulfil some of the criteria needed for a hormone. (UK)

  12. Sensitive radioimmunoassay for plasma arginine vasopressin

    International Nuclear Information System (INIS)

    Thibonnier, M.; Soto, M.E.; Corvol, P.; Milliez, P.; Marchetti, J.; Menard, J.

    1980-01-01

    Using an ion exchange resin, a sensitive radioimmunoassay for plasma arginine vasopressin (AVP) was developed. This assay was characterized by the absence of blank values, an excellent recovery rate, great sensitivity (0.1 pg of AVP was significantly detected) and reproducibility. In 8 normal men, plasma AVP after overnight dehydration was 1.57+-0.17 pg/ml, and dropped to 0.58+-0.11 pg/ml after 20 ml/kg oral water loading. Significant correlations between plasma AVP levels and plasma or urinary osmolality confirm the validity of this assay. In complete pituitary diabetes insipidus (n=4) plasma AVP was undetectable whereas it was frankly increased in Schwartz-Bartter syndrome (3 to 33 pg/ml, n=8) [fr

  13. Standardised multicentre procedure for plasma gonadotrophin radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, K M; Hayes, M; Jeffcoate, S L [Chelsea Hospital for Women, London (UK)

    1982-09-01

    A radioimmunoassay method for the assay of luteinising hormone (LH) and follicle-stimulating hormone (FSH) in serum/plasma has been designed for use in laboratories of varying expertise in the United Kingdom. The major sources of experimental error leading to poor within-laboratory performance and between-laboratory comparability were identified: quality of tracer, use of calibration standards, and separation procedure. A simple rugged kit was designed which was extensively tested first in our laboratory and then in a small multi-centre field trial before being made available. It is now used routinely by 26 health service and research laboratories. The working range of the assays is 1-50 IU/l (LH) and 0.3-16 IU/l (FSH). The between-batch reproducibility was 5-11% (CV) over the dose range 4.8-18 IU/l (LH) and 1.6-15 IU/l (FSH).

  14. Radioimmunoassay of 17-beta - estradiol in plasma

    International Nuclear Information System (INIS)

    Kyian, T.S.; Wajchenberg, B.L.

    1980-01-01

    A radioimmunoassay technique for the measurement of plasma E 2 was standardized utilizing a highly specific antisera against E 2 [-6(-0-carboximetil)-oxime] BSA without the need of previous chromatographic purification. The anti-E 2 serum was highly specificic, showing high affinity with affinity constants:K 1 =1.62 x 10 12 M -1 and K 2 =2.94x10 11 M -1 , calculated by Scatchard plot. The standard-curve sensitivity was 2 picograms. The method was specific and accurate, showing an intra-assay precision with a mean C.V. of 2.9%, with the inter-assay evaluation showing a mean C.V. of 5.0%. This method was employed to evaluate E 2 secretion during the menstrual cycle in 6 normal female. (Author) [pt

  15. Radioimmunoassay in basic and clinical pharmacology

    International Nuclear Information System (INIS)

    Patrono, C.; Peskar, B.A.

    1987-01-01

    The subject of the book is the development, validation and application of radioimmunoassay (RIA) techniques for the measurement of a variety of substances in animal and human body fluids. The book discusses methodological and conceptual issues related to the main classes of mediators of drug action and to drugs themselves, as assayed by this particular analytical technique. A number of introductory chapters provide basic information concerning production and characterization of antibodies, labeling techniques, statistical aspects and validation criteria, insight into problems related to the development and validation of RIA for the newly discovered mediator(s). In the following chapters, the emphasis is placed on the technical details relevant to each class of compounds and on specific aspects of their applications to basic and/or clinical pharmacological studies. New developments in this area, such as monoclonal antibodies and non-radioactive labeling techniques, are also covered

  16. Beta-endorphin radioimmunoassay: specificity studies

    Energy Technology Data Exchange (ETDEWEB)

    Colas-Linhart, N.; Perdrisot, R.; Petiet, A.; Bok, B.

    1986-01-01

    This note describes the technical details of a cerebrospinal fluid (CSF) B-Endorphin (B-End) radioimmunoassay (RIA). We used an antiserum raised in rabbits against human B-End which cross-reacs 100% with B-Lipotrophin (B-Lph). Thus, filtration chromatography is used to separate both peptides. The assay is sensitive (limit detection=14 pmoles/l), reproducible (the intra and inter assay coefficients of variation are 5 and 6% respectively). Specificity studies are performed to verify the cross-reactions with other opioid peptides and the non specific reactions with the biological fluid (CSF). In order to evaluate the effects of iodine-containing contrast media on the RIA, additional standard curves were analyzed in the presence of varying concentrations of two contrast materials.

  17. Quantitation of secretory protein levels by radioimmunoassay

    International Nuclear Information System (INIS)

    Klein, J.L.; Dawson, J.R.

    1978-01-01

    A radioimmunoassay was designed for the detection of secretory protein, a component of secretory immunoglobulin A, in human serum. The assay uses free secretory protein isolated from human colostrum, and antisera raised in rabbits to be purified antigen. The mean level of secretory protein in the control group was 2.34+-0.41 μg/ml (mean+-S.E.M.). The level in cord blood was slightly lower (0.74+-0.26 μg/ml), while the level in patients with ovarian carcinoma was significantly increased (12.67+-1.43 μg/ml). Pregnant women have increasingly secretory protein levels with increasing length of gestation (5.86+-2.02, 11.55+-1.30 and 17.00+-1.16 μg/ml for the first, second and third trimesters, respectively. (Auth.)

  18. Radioimmunoassay for progesterone in bovine milk

    International Nuclear Information System (INIS)

    Ruiz, Miriam; Figueredo, Nancy; Castillo, Sonia; Pizarro

    2002-01-01

    A system for the measurement of progesterone in bovine milk by radioimmunoassay has been developed and validated. This assay includes an iodine tracer purified by HPLC, the standard prepared in fat-free milk and an antibody anti-progesterone combined with second antibody. The detection limit of the assay is at 0.2 nmol/L calculated from the maximum binding menus two standard deviations and the precision is satisfactory. In the recovery assay was used 4 milk different samples and the result was 98% of recuperation. The progesterone was determinate in milk samples from post-partum animals taking samples three times per week for 40 days. The assay is simple, rapid and possibility the progesterone measurement without sample dilution, distinguish the cyclic changes of this hormone that reflect the ovarian activity in the animals. (author)

  19. Radioimmunoassay for GRF and CRF in humans

    International Nuclear Information System (INIS)

    Stalla, G.K.; Losa, M.; Kaliebe, T.; Stalla, J.; Schopohl, J.; Muller, O.A.; Von Werder, K.

    1987-01-01

    In 1981 the structure of ovine CRF was established. One year later others isolated a 44 amino acid peptide with GH releasing activity from a pancreatic islet cell carcinoma of an acromegalic patient (hp GRF/sup 1-44/). In 1983 the gene of human CRF was cloned and the amino acid sequence of hCRF could be elucidated. It differs in 7 amino acids from oCRF. Many investigators demonstrated the biological activity of these peptides in vitro and in vivo. The aim of the authors study was to establish radioimmunoassays for GRF and hCRF with the synthetic derivates, measure endogenous GFR and CRF and circulating GRF- and CRF-levels after intravenous injection and calculate metabolic clearance rate and half-time of disappearance from serum for both releasing hormones

  20. Radioimmunoassay of human plasma protein C

    International Nuclear Information System (INIS)

    Wang Bocheng; Li Jinquan; Jing Jian; Zhang Manda

    1995-01-01

    A radioimmunoassay method for the measurement of human plasma protein C (PC) is established. PC was isolated and purified from human plasma. The antisera against PC was obtained by immunizing rabbits. Iodination of PC was carried out with chroramine-T. The sensitivity was 3.94% μg/L, and the assay covered 6.25∼1024 μg/L for PC. The intra-assay and inter-assay CV were 4.4% and 9.68% respectively, with a recovery rate of 104.28%. There was no cross reaction with factor II. The normal value was 3.84 +- 0.34 mg/L in 36 normal persons. Value of 1.03 +-0.41 mg/L was found in 16 patients with fulminating hepatitis complicated with coagulation disturbance. It is an effective approach for the diagnosis of hereditary or acquired PC deficiency and also for the study of thrombotic diseases

  1. Radioimmunoassay for medical diagnosis and research

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, R A; Vavrejn, B [International Atomic Energy Agency, Vienna (Austria). Div. of Life Sciences

    1982-12-01

    Health and disease in living systems depend on the dynamic interplay of thousands of biochemical substances occurring in living systems in concentrations ranging from parts per hundred to parts per billion or trillion. Radioimmunoassay (RIA) is a highly specific and sensitive technique for measuring the concentration of such biochemical substances. It represents one of the most dramatically expanding areas of medical diagnosis and research. Reviewed here is the recent progress on RIA, with emphasis on methodology and on its adaptation and application in developing countries. The number of biological substances (ligands) being assayed by RIA continues to expand. RIA is central to diagnosis, epidemiology and research. It has been successfully applied in the study of parasitic and infectious diseases. Introduction of RIA into developing countries, for which the Agency's help is sought and given, presents numerous problems: personnel, equipment, adaptability of techniques to local needs, and public support.

  2. Radioimmunoassay of urine oxytocin in man

    International Nuclear Information System (INIS)

    Zebidi, A.; Geelen, G.; Allevard, A.M.; Sempore, B.; Jarsaillon, E.; Meunier, C.; Gharib, C.

    1978-01-01

    A radioimmunoassay (RIA) for oxytocin (OT) in urine is described. 125 I-OT was prepared, and antibodies were raised in rabbits against OT coupled to bovine serumalbumine. This allowed us to set up a RIA for OT which limit of detection is 1.25 pg/tube (0.6 μU). The use of an extraction procedure using CG 50 Amberlite is essential. The recovery after extraction reaches 70.5 %. pH 5 is the optimum pH were urine samples must be stored. The superposition of the elution peak of endogenous OT on that of exogenous hormone is an argument in favour of the validity of such an extraction procedure. Daily urinary excretion of OT reaches 9.58 mU +- 3.48 in 18 healthy young men [fr

  3. Radioimmunoassay of cholecystokinin in tissue and plasma

    International Nuclear Information System (INIS)

    Jansen, J.B.M.J.

    1984-01-01

    The physiological and pathophysiological role of the pancreas hormone, the polypeptide 'cholecystokinin' (CCK) is not well-established yet. This is due to the lack of specific and reliable radioimmunoassays for CCK. The aim of this thesis is to develop such an assay meeting the requirements of high specificity and sensitivity. Several problems were faced, such as (1) the cross-reactivity of existing antibodies with the stomach hormone gastrin and (2) changes in immunoreactivity caused by the introduction of the labelling isotope 125 I and various labels (prepared according to the Bolton-Hunter method) into the polypeptide. The reliability of the assay for the measurement in human tissue and blood is extensively evaluated, inter alia, in patients with pancreas insufficiency (alcohol, cystic fibrosis) and with coeliac disease. (Auth.)

  4. Radioimmunoassays for catalase and glutathion peroxidase

    International Nuclear Information System (INIS)

    Baret, A.; Courtiere, A.; Lorry, D.; Puget, K.; Michelson, A.M.

    1982-01-01

    Specific and sensitive radioimmunoassays for human, bovine and rat catalase (CAT) and glutathion Peroxidase (GPX) are described. The obtained values are expressed as enzymatic units per μg of immunoreactive protein. They appear to closely correspond to specific activities of the purified enzymes determined by colorimetric protein-assay. Indeed, the values of the specific activities of purified human CAT is 57.9 k/mg and that of purified rat GPX is 180 units/mg. This result validates the present RIAs and the association of the two techniques allows the determination of a further parameter. In conclusion, RIAs for CAT and GPX can be applied with great specificity and sensitivity to a wide variety of human, rat and bovine medias

  5. Radioimmunoassay of progesterone in unextracted serum

    International Nuclear Information System (INIS)

    Haynes, S.P.; Corcoran, J.M.; Eastman, C.J.; Doy, F.A.

    1980-01-01

    A rapid, precise radioimmunoassay for progesterone in 25 μL of unextracted serum is described. Progesterone is released from its binding protein by adding an optimal amount of cortisol, which binds to the same protein (cortisol binding globulin) as progesterone. The amount of cortisol required does not cross react with the specific progesterone antibody used. This approach considerably shortens assay time and removes a tedious and imprecise stage in the conventional assay of serum progesterone. Results correlated well (r = 0.97) with a method involving organic solvent extraction of progesterone from serum. During the two years we have used this mehod in a busy diagnostic endocrine laboratory, the between-assay precision (CV) for low-, medium-, and high-concentration quality control sera was 12, 7, and 9%, respectively. Data from participation in an independent external quality-control program verified the adequacies of the method

  6. A beta-endorphin radioimmunoassay: specificity studies

    International Nuclear Information System (INIS)

    Colas-Linhart, N.; Perdrisot, R.; Petiet, A.; Bok, B.

    1986-01-01

    This note describes the technical details of a cerebrospinal fluid (CSF) B-Endorphin (B-End) radioimmunoassay (RIA). We used an antiserum raised in rabbits against human B-End which cross-reacs 100% with B-Lipotrophin (B-Lph). Thus, filtration chromatography is used to separate both peptides. The assay is sensitive (limit detection=14 pmoles/l), reproducible (the intra and inter assay coefficients of variation are 5 and 6% respectively). Specificity studies are performed to verify the cross-reactions with other opioid peptides and the non specific reactions with the biological fluid (CSF). In order to evaluate the effects of iodine-containing contrast media on the RIA, additional standard curves were analyzed in the presence of varying concentrations of two contrast materials [fr

  7. Radioimmunoassay of cholecystokinin in human plasma

    International Nuclear Information System (INIS)

    Byrnes, D.J.; Henderson, L.; Borody, T.; Rehfeld, J.F.

    1981-01-01

    A sensitive radioimmunoassay for cholecystokinin (CCK) has been developed. Porcine CCK-33 was labelled by conjugation with 125 I-hydroxyphenyl-propionic acid succinimide ester. Antibodies were raised against porcine CCK-33 covalently coupled to egg albumin. Plasma samples were extracted with 96% ethanol prior to assay. Free and bound hormone were separated by dextran-coated charcoal. The antibodies bound CCK-8 and CCK-33 with equimolar potency. The assay detection limit was 1 pmol/l plasma. Within and between assay coefficients of variation were +-12.7 and 13.0% at mean plasma CCK concentrations of 13.2 and 13.6 pmol/l. The concentration of CCK in 47 normal fasting subjects ranged from undetectable to 22 pmol/l. Ingestion of a mixed meal in 9 normal subjects increased the plasma concentration from 8.3 +- 2.5 S.E. to 24.4 +- 6.5 pmol/l. (Auth.)

  8. Radioimmunoassay of influenza A virus haemagglutinin. I

    International Nuclear Information System (INIS)

    Russ, G.; Styk, B.; Polakova, K.

    1978-01-01

    Haemagglutinin released from influenza A virus recombinant MRC11 [antigenically identical to the strain A/Port Chalmers/1/73 (H3N2)] by bromelain treatment and purified by rate zonal centrifugation (further on B-HA) was examined for possible contamination by neuraminidase. Specific enzymatic activities of the MRC11 virus and the B-HA respectively showed that B-HA contained less than 0.1% of enzymatically active neuraminidase originally present in the virus. Gel double diffusion tests, specificities of rabbit antisera induced by B-HA as well as radioimmunoprecipitation experiments demonstrated that B-HA was devoid of any antigenically active neuraminidase. Precipitation of 125 I-labelled B-HA with antisera to influenza virus recombinants with N2 neuraminidase was evidently caused by antibodies to host antigenic determinant(s) present in these sera. As for purity and radioimmunoprecipitation properties, B-HA is quite suitable for radioimmunoassay experiments. (author)

  9. Automatic computation of radioimmunoassay data. Insulin and C-peptide

    Energy Technology Data Exchange (ETDEWEB)

    Toyota, T; Kudo, M; Abe, K [Hirosaki Univ., Aomori (Japan). School of Medicine; Kawamata, F; Uehata, S

    1975-09-01

    Radioimmunoassay provided dose response curves which showed linearity by the use of logistic transformation (Rodbard). This transformation which was applicable to radioimmunoassay should be useful for the computer processing of insulin and C-peptide assay. In the present studies, standard curves were analysed by testing the fit of analytic functions to radioimmunoassay of insulin and C-peptides. A program for use in combination with the double antibody technique was made by Dr. Kawamata. This approach was evidenced to be useful in order to allow automatic computation of data derived from the double antibody assays of insulin and C-peptides. Automatic corrected calculations of radioimmunoassay data of insulin was found to be satisfactory.

  10. Determination of plasma oxytocin by radioimmunoassay

    International Nuclear Information System (INIS)

    Ogawa, Satsuki; Fukuchi, Soitsu; Miura, Tadashi

    1978-01-01

    A simple radioimmunoassay was applied to the measurement of oxytocin in human plasma. A high specificity of immunoassay was demonstrated by the fact that large excess of angiotensin I and II, and ACTH did not displace labelled oxytocin from the antibody. Lysine-8-vasopressin and arginine-8-vasopressin showed very little cross-reaction in the assay, possessing only 0.002% of the immunological potency of oxytocin. The specific activity of 125 I-oxytocin was 166 μCi/μg. Adsorption and extraction capacities of Florisil were 96.6 +- 2.1% and 85.7 +- 2.5%, respectively. Intra- and inter-assay variability were 7.2 +- 4.9% and 4.3 +- 2.2%, respectively. The sensitivity of the assay was below 1 pg/tube. Normal levels of plasma oxytocin were 0 - 2.2 pg/ml (n=13) in males and 0 - 10.4 pg/ml (n=10) in females. Plasma oxytocin levels in the 39th and 40th weeks of pregnancy were 27.9 +- 4.14 pg/ml (n=4) and 29.8 +- 17.1 pg/ml (n=13), respectively. The levels increased to 33.1 +- 12.1 pg/ml (n=7) and 37.1 +- 17.5 pg/ml (n=7) in the first and third stages of labor, and decreased to 13.6 +- 5.25 pg/ml (n=6) on the 2nd to 8th day after labor. The radioimmunoassay for oxytocin in plasma is considered to be sufficiently applicable for clinical use. (auth.)

  11. Two-monoclonal-antibody sandwich-type assay for thyrotropin, with use of an avidin-biotin separation technique

    International Nuclear Information System (INIS)

    Odell, W.D.; Griffin, J.; Zahradnik, R.

    1986-01-01

    We have developed a sensitive, specific, noncompetitive, sandwich-type radioimmunoassay for human thyrotropin (hTSH), which can be performed in 30 min. The assay involves two monoclonal antibodies, selected for high affinity and specificity and also for reaction against antigenic sites on hTSH that are distal from each other. One of these antibodies is labeled with 125 I; the other is conjugated covalently to biotin. Polystyrene beads were also conjugated covalently to biotin. After conjugation, the beads were incubated with avidin. These beads represent a rapid, simple method for separating hTSH-bound antibody from free antibody. The biotin-antibody-hTSH- 125 I-labeled antibody complexes bind to the beads and hTSH concentration is directly related to counts per minute. This assay can detect hTSH at a concentration of 0.06 milli-unit/L in serum

  12. Radioimmunoassay of methaqualone in human urine compared with chromatographic methods

    International Nuclear Information System (INIS)

    Mule, S.J.; Kogan, M.; Jukofsky, D.

    1978-01-01

    The 125 I-radioimmunoassay for methaqualone in human urine was evaluated by a comparison with newly modified gas-liquid chromatographic and thin-layer chromatographic methods. The statistically significant sensitivity value for the radioimmunoassay was at 2 μg of methaqualone per liter of urine. The coefficient of variation was 2.88 -+ 0.16% intraassay. There was cross-reactivity only with metabolites of methaqualone, 4'-hydroxymethaqualone being twice as sensitively measured as methaqualone. There was complete agreement between results by radioimmunoassay and by gas-liquid chromatography in 96.7% of the samples analyzed. Only 1.2% of the radioimmunoassay values were false positives, and 2.1% false negatives (phi = 0.8917, P < 0.001). Comparisons between the thin-layer chromatographic data and the gas--liquid chromatographic or radioimmunoassay data showed less agreement because of the 50- to 200-fold higher sensitivity of the latter techniques. Gas--liquid chromatography therefore appears to represent the best reference method for the evaluation of the radioimmunoassay, which appears to be a very sensitive and reliable technique for detecting methaqualone and its metabolites in human urine

  13. Sandwich veto detector at COMPASS experiment

    International Nuclear Information System (INIS)

    Sarkar, S.; Dasgupta, S.S.; Calcutta-COMPASS group

    2010-01-01

    This paper presents the newly build Sandwich Detector for 190 GeV hadron run of COMPASS Experiment at CERN. The technical details and the testing procedures are included to highlight the physics objective of the installation. Single electron detection techniques has been developed and used to scale the performance of the detector. This analysis can predict the number of single electrons per MIP at the scintillation detector. (author)

  14. Failure modes of composite sandwich beams

    OpenAIRE

    Gdoutos E.; Daniel I.M.

    2008-01-01

    A thorough investigation of failure behavior of composite sandwich beams under three-and four-point bending was undertaken. The beams were made of unidirectional carbon/epoxy facings and a PVC closed-cell foam core. The constituent materials were fully characterized and in the case of the foam core, failure envelopes were developed for general two-dimensional states of stress. Various failure modes including facing wrinkling, indentation failure and core failure were observed and compared wit...

  15. Sandwich design for ships and railway wagons

    Energy Technology Data Exchange (ETDEWEB)

    Olsson, K.-A. [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Aeronautics

    2000-07-01

    In Sweden we have long experience of different types of vehicles and ships in sandwich construction, especially for Navy ships, such as minesweepers, mine-counter-measure-vessels and corvettes. As face materials mostly GRP and FRP have been used, but also metallic materials of Al-alloys, coated carbon steel and stainless steel. Core materials have usually been cellular plastic foams of cross-linked PVC, but also extruded PS, PUR, PEI and PMI. A lot of different continuous and discontinuous manufacturing processes are used. Vacuum assisted infusion is used in the last years, because it is a closed process, gives high fibre content and a good quality of the laminates. Sandwich design has mainly been used in the transportation area, where lightweight design is needed to give higher performance and load bearing capacity. The use of sandwich will give high stiffness- and strength-to weight ratio. These are in most cases not enough from economic point of view, but even other integrated functions must be considered, i.e. insulation, energy consumption, damping, less components, lower manufacturing costs, low maintenance, signature effects (military) etc. (orig.)

  16. Radioimmunoassay and related procedures in medicine

    International Nuclear Information System (INIS)

    1978-01-01

    Full text: Radioassay procedures for the measurement of substances such as hormones, vitamins and drugs in the body fluids and tissues, above all in the blood, are now in the front rank of medical applications of radioactive materials. These procedures, which are carried out on specimens in the medical laboratory and do not involve the administration of any radioactive material to the patient, are now widely employed in the routine diagnosis and investigation of disease, whilst their use in research has led to important advances in many branches of medicine. Typical of radioassay methods is radioimmunoassay, which depends on the antigen-antibody reaction between the substance to be measured and the antibodies in an antiserum against that substance produced in a guinea-pig, rabbit, sheep or other animal. The importance of radioimmunoassay was recently underlined by the award of the Nobel Prize in medicine for 1977 to Dr. Rosalyn Yalow of the United States of America for her pioneer work on the method over the past two decades, particularly in relation to the measurement of protein hormones. This symposium was the third on the subject to have been sponsored by the IAEA. The first took place in Vienna in 1969 and the second in Istanbul in 1973. During the four years from 1973 to 1977, the growing commercial availability of reagents and kits for radioassays brought them into routine use. This in turn led to an increasing awareness of the need for assay standardization and quality control and to an increasing attention to techniques of assay data analysis. The burgeoning demands made on assay services stimulated interest in the possibilities for automation of assay procedures. Promising new methods were developed, notably solid-phase radioassay and radioreceptor assay. At the same time there was a resurgence of interest in alternative assay methods not based on the use of radioactive materials, which made a critical re-examination of the entire subject desirable. The

  17. Radioimmunoassay and related procedures in medicine

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1978-02-15

    Full text: Radioassay procedures for the measurement of substances such as hormones, vitamins and drugs in the body fluids and tissues, above all in the blood, are now in the front rank of medical applications of radioactive materials. These procedures, which are carried out on specimens in the medical laboratory and do not involve the administration of any radioactive material to the patient, are now widely employed in the routine diagnosis and investigation of disease, whilst their use in research has led to important advances in many branches of medicine. Typical of radioassay methods is radioimmunoassay, which depends on the antigen-antibody reaction between the substance to be measured and the antibodies in an antiserum against that substance produced in a guinea-pig, rabbit, sheep or other animal. The importance of radioimmunoassay was recently underlined by the award of the Nobel Prize in medicine for 1977 to Dr. Rosalyn Yalow of the United States of America for her pioneer work on the method over the past two decades, particularly in relation to the measurement of protein hormones. This symposium was the third on the subject to have been sponsored by the IAEA. The first took place in Vienna in 1969 and the second in Istanbul in 1973. During the four years from 1973 to 1977, the growing commercial availability of reagents and kits for radioassays brought them into routine use. This in turn led to an increasing awareness of the need for assay standardization and quality control and to an increasing attention to techniques of assay data analysis. The burgeoning demands made on assay services stimulated interest in the possibilities for automation of assay procedures. Promising new methods were developed, notably solid-phase radioassay and radioreceptor assay. At the same time there was a resurgence of interest in alternative assay methods not based on the use of radioactive materials, which made a critical re-examination of the entire subject desirable. The

  18. Increased specificity in human cardiac-myosin radioimmunoassay utilizing two monoclonal antibodies in a double sandwich assay

    International Nuclear Information System (INIS)

    Katus, H.A.; Hurrell, J.G.; Matsueda, G.R.; Ehrlich, P.; Zurawski, V.R. Jr.; Khaw, B.-A.; Haber, E.

    1982-01-01

    An immunoradiometric assay that simultaneously measured two different epitopes on the same molecule was devised to differential between cardiac- and skeletal-myosin light chains. Three monoclonal antibodies were examined that were 100% (lC5), 25% (2B9) and 17% (4F10) cross reactive, respectively, between the two antigens. One antibody of the pair to be studied was immobilized to cyanogen bromide-activated Sepharose 4B while the other was iodinated with 125 I using the lactoperoxidase method. The antigen was mixed with the immobilized antibody, the labeled antibody was added and the precipitate then washed and counted in a gamma counter. When both antibodies of the pair to be studied (immobilized and labeled) were the same (2B9), no radioactivity above background was bound to the precipitate, indicating that the second antibody could not bind to an already occupied epitope. When two different antibodies were employed, the specificity of the assay increased over that of a single antibody. The cross reactivity of a pair approximated the product of the cross reactivities of the individual antibodies. Thus, lC5 and 2B9 were 25% cross reactive together, lC5 and 4F10 17% cross reactive, and 2B9 and 4F10 4.3% cross reactive. (author)

  19. Radioimmunoassay and the hormones of thyroid function

    International Nuclear Information System (INIS)

    Stahl, R.J.

    1975-01-01

    Radioimmunoassay (RIA) has provided the tools for wide-reaching investigations that have changed and continue to change many important concepts of thyroid physiology and pathophysiology. The RIA for human thyrotropin (TSH) was developed in 1965; development of the RIA for triiodothyronine (T 3 ), thyroxine(T 4 ), thyroxine-binding globulin (TBG), and recently, thyrotropin-releasing hormone (TRH) and thyroglobulin (Tg) followed. The capacity to measure nanogram and picogram concentrations with relative ease and speed has permitted the demonstration of dynamic relationships of the intrathyroidal and circulating thyroid hormones to each other and to the pituitary and hypothalamic regulating hormones. Evidence for the presence of cross-influences between TRH and other hypothalamic regulating hormones on the secretion of pituitary hormones has accumulated. The impact of the new information on clinical practice is now becoming evident. There is new appreciation of the value of assaying serum T 3 and TSH concentrations in the clinical management of patients with disturbed function of the thyroid, pituitary, or hypothalamus. The necessary components for RIA performance can be purchased separately or in kit form from commercial sources. With appropriate quality-control procedures, precise, sensitive, and reliable data can be generated. Awareness of the specific technical problems relating to the RIA of these hormones is absolutely necessary to assure reliable results. The availability of kits or their components permits the performance of these studies in the community hospital and in reliable commercial-service laboratories. (U.S.)

  20. Chemical Kinetics of Progesterone Radioimmunoassay System

    International Nuclear Information System (INIS)

    Abdel-Fattah, A.A.; Moustsfs, K.A.; El-Kolally, M.T.

    2004-01-01

    Progesterone is one of the steroids secreted by the corpus Iuteum in females during the menstrual cycle, and in a much higher amount by the placenta during pregnancy. It is also secreted in a minor quantities by the adrenal cortex in both males and females. Measurement of serum progesterone represents one of diagnostic values in menstrual disorders and infertility. The progesterone radioimmunoassay is based on the competition between unlabelled progesterone and a fixed quantity of 125 I-labeled progesterone for a limited number of binding sites on progesterone specific antibody. Allowing for a fixed amount of magnetizable immunosorbent to react, the antigen-antibody complex is bound on solid particles which are then separated by magnetic rack, and the radioactivity of the solid phase was counted using gamma counter. In this work, the chemical kinetics of the assay was followed, where the specific rate constant (K) was calculated at 4 degree and 37 degree and the activation energy (E act ) were calculated and the reaction rate was deduced

  1. Radioimmunoassay in developing countries: General principles

    Energy Technology Data Exchange (ETDEWEB)

    Piyasena, R D

    1993-12-31

    Radioimmunoassay (RIA) is probably the most commonly performed nuclear medicine technique. It is an in vitro procedure, where no radioactivity is administered to the patient. But this alone is not the reason for its widespread use. It provides the basis for extremely sensitive and specific diagnostic tests, and its use in present day medicine has brought a virtual information explosion in terms of understanding the pathophysiology of many diseases. The fact that the technology involved is within the technical and economic capabilities of the developing world is evident from the increasing demand for its introduction or expansion of existing services. RIA facilities need not be restricted to urban hospitals, as in the case of in vivo nuclear medicine techniques, but may be extended to smaller district hospitals and other laboratories in peripheral areas. It is also possible to send blood samples to a central laboratory so that a single centre can serve a wide geographical area. There are many laboratories in the industrialized world that receive a major proportion of samples for assay by mail. In recent years, substantial RIA services have been established in many of the developing countries in Asia and Latin America. The International Atomic Energy Agency (IAEA) and World Health Organisation (WHO) have made vital contributions to these activities and have played a catalytic role in assisting member states to achieve realistic goals. In the past five years, more than 250 individual RIA laboratories in developing member states have been beneficiaries of IAEA projects

  2. Radioimmunoassay study of neurophysins in human plasma

    International Nuclear Information System (INIS)

    Reinharz, A.C.; Tissot-Berthet, M.-C.; Vallotton, M.B.

    1978-01-01

    Using a homologous system we have developed a specific and sensitive radioimmunoassay for the measurement of one of the human neurophysins in unextracted human plasma. This neurophysin is specifically secreted in response to oestrogen and has therefore been referred to as human oestrogen-stimulated neurophysin (h-OeSN). The plasma concentration was 0.57 plus minus 0.17 ng/ml (SD) in females and 0.88 plus minus 0.76 ng/ml (SD) in males. This difference is not significant. In women on oral contraceptives, plasma h-OeSN was 2.0 plus minus 1.1 ng/ml. During pregnancy h-OeSN increased progressively to 3.7 plus minus 2.9 ng/ml at the end of the first trimester, and 5.2 plus minus 2.8 ng/ml at term. Plasma h-OeSN concentrations increased rapidly and markedly in men treated with ethinyl-oestradiol. We have also demonstrated the presence of h-OeSN in amniotic and cerebrospinal fluids. A second human neurophysin, which is stimulated by nicotine but not by oestrogen, was also measured. This neurophysin was monitored by a heterologous system using antiserum raised against bovine neurophysin II (b-NII), and b-NII as the standard and tracer. (author)

  3. Radioimmunoassay of creatine kinase BB isoenzyme

    Energy Technology Data Exchange (ETDEWEB)

    Jianguo, Geng [Shanghai Medical Univ. (China). Zhongshan Hospital; and others

    1988-11-01

    A radioimmunoassay of creatine kinase BB isoenzyme (CK-BB) was developed by using CK-BB purified from human brain. The CK-BB antiserum was raised by immunizing rabbite and {sup 125}I-CK-BB iodinated with Bolton-Hunter reagent. The affinity constant was 3.0 x 10{sup 9} mol/L. No cross reactions with creatine kinase MM isoenzyme and neuron-specific enolase were found. The measuring range was 3.5 x 10{sup -8} {approx} 1.2 x 10{sup -5} mmol/L, the average recovery rate 97.5%, with the inter and intrassay CV 3.1% and 12%, respectively. The average serum CK-BB concentration in 83 normal persons was 1.5 x 10{sup -7} +- 8.1 x 10{sup -8} mmol/L, quite different from the values of acute myocardial infarction (5.2 x 10{sup -6} +- 1.2 x 10{sup -4} mmol/L, n = 28) and cerebral vascular accident (8.4 x 10{sup -4} +- 5.0 x 10{sup -4} mmol/L, n = 10).

  4. Radioimmunoassay of bovine heart protein kinase

    International Nuclear Information System (INIS)

    Fleischer, N.; Rosen, O.M.; Reichlin, M.

    1976-01-01

    Immunization of guinea pigs with bovine cardiac cAMP-dependent protein kinase (ATP : protein phosphotransferase, EC 2.7.1.37) resulted in the development of precipitating antibodies to the cAMP-binding subunit of the enzyme. Both the phosphorylated and nonphosphorylated cAMP-binding protein of the protein kinase reacted with the antiserum. A radioimmunoassay was developed that detects 10 ng of holoenzyme and permits measurement of enzyme concentrations in bovine cardiac muscle. Bovine liver, kidney, brain, and skeletal muscle contain protein kinases which are immunologically identical to those found in bovine cardiac muscle. However, the proportion of immunoreactive enzyme activity differed for each tissue. All of the immunologically nonreactive enzyme in skeletal muscle and heart was separable from immunoreactive enzyme by chromatography on DEAE-cellulose. Rat tissues and pig heart contained protein kinase activity that cross reacted immunologically in a nonparallel fashion with bovine cardiac enzyme. These results indicate that cAMP-dependent protein kinases within and between species are immunologically heterogeneous

  5. Radioimmunoassay for 2,4-dichlorophenoxyacetic acid

    International Nuclear Information System (INIS)

    Knopp, D.; Dobberkau, H.J.; Nuhn, P.

    1985-01-01

    Antisera to 2,4-dichlorophenoxyacetic acid (2,4-D), a widely used herbicide, have been obtained from rabbits following immunization with various 2,4-D-protein conjugates. Employing [ 125 I] 2,4-D-tyramine as the radioligand for the antisera, very poor assay sensitivity was achieved because of a much higher affinity of the antibodies to the tracer. When using [6- 3 H] 2,4-D (specific radioactivity 465 GBq/mmol) a sensitive and specific radioimmunoassay (RIA) for 2,4-D could be developed, which allows determination directly in water, plasma and urine samples. Levels as low as approximately 100 pg (450 femtomoles) of 2,4-D can be detected. The antiserum is fairly specific for 2,4-D. Other related phenoxycarboxylic acids and dichlorophenol showed a cross-reactivity smaller than 10%. After a single administration of 2,4-D (0.91 mg/100 g body weight, orally) to rats, plasma and urine levels were determined at different times. Results correspond to those found in the literature, thus indicating the utility of the RIA. Further applications and limitations are discussed. (orig.)

  6. Radioimmunoassay of arginine vasopressin in human plasma

    International Nuclear Information System (INIS)

    Uhlich, E.; Weber, P.; Groeschel-Stewart, U.; Roeschlau, T.; Wuerzburg Univ.

    1975-01-01

    Antibodies for the radioimmunoassay of arginine vasopressin (AVP) described here were produced in rabbits using synthetic AVP coupled to rabbit γ-globulin with carbodiimide. In three out of six rabbits, significant antibody titres were obtained. Using the best antisera produced, 40% of labelled AVP was bound at a final dilution of 1 : 50,000. After iodination of synthetic AVP with 125 I using the chloramin-T method, a gel filtration on Sephadex G-25 was performed to purify the iodinated AVP. For separation of antibody bound and free hormone, a second antibody precipitation was used. There was no crossreactivity with oxytocin. AVP was extracted from plasma after ammoniumsulfate precipitation of the proteins by adsorption to Florisil. The recovery of AVP added to plasma in amounts of 5-25 pg/ml was 60 +- 15% (n = 6). The minimum amount of AVP detectable was 1 pg per ml plasma. The plasma level in normal adults under standard conditions was 3.4 +- 2.2 pg/ml. This is in agreement with data recently published by other researchers. The applicability and reproducibility was further tested in measurements of samples taken hourly during the entire day under water diuresis and after hormonal stimulation of AVP. (orig.) [de

  7. Falsely elevated triiodothyronine values in radioimmunoassay

    International Nuclear Information System (INIS)

    Skovsted, L.; Moelholm Hansen, J.E.; Nygaard, B.

    1995-01-01

    Five patients with falsely elevated serum triiodothyronine (T 3 ) concentrations (>9 nmol/l) in a radioimmunoassay are reported. The high T 3 -values disagreed with the other thyroid variables investigated as well as with the clinical observations. In sera from all patients a normal non-specific binding of T 3 was found, thus excluding abnormal serum-protein-binding of the hormone. An ethanol extraction of T 3 from serum before RIA reduced the T 3 content in serum from all patients to normal levels (2.0-2.4 nmol/l). These findings indicate the presence in the sera of substances, probably of protein nature, that were interfering with the assay by binding the reagent-antibody and not the antigen. Addition of non-immune rabbit serum prevented this interference and normalized the T 3 -values (1.8-2.4 nmol/l). Thus the interfering substance in T 3 -RIA could be an anti-rabbit antibody, the interaction of which can be eliminated by a minor modification of the assay making it possible to differentiate true from false T 3 -values. (au) 16 refs

  8. Combined radioimmunoassay for triiodothyronine and thyroxine

    International Nuclear Information System (INIS)

    Denning, C.E.; Schick, L.A.

    1980-01-01

    A method for the combined radioimmunoassay for the hormones triiodothyronine (T-3) and thyroxine (T-4) in serum or plasma, wherein the radiolabeled t-3 and t-4 reagents are t-3 and t-4 labeled with the same radioisotope. The hormones are extracted from the serum or plasma sample and separated from their binding proteins by adsorption to a crosslinked dextran gel at a highly alkaline ph. After washing away the dissociated proteins, a predetermined limiting amount of t-3 antibody is incubated with the gel and thereafter radiolabeled t-3 which has become extracted from the gel by antibody binding is washed away. Excess t-3 antibody and a predetermined limiting amount of t-4 antibody are then incubated with the gel and radiolabeled t-3 and t-4 which has become extracted from the gel by antibody binding are thereafter washed away. The respective relative amounts of radiolabeled t-3 and t-4 retained by the gel after the incubations with the respective limiting amounts of t-3 and t-4 antibody are compared with standard results to quantitate the hormones in the sample. The use of excess t-3 antibody in the t-4 antibody incubation is critical to the accuracy of the method, enabling the use of the same radioisotope for radiolabeling t-3 and t-4

  9. Radioimmunoassay of renin in human renal tissues

    International Nuclear Information System (INIS)

    Wowra, B.

    1981-01-01

    A method has been developed to quantitatively determine renin in human kidney tissue. The angiotensin I split off angiotensinogs by renin was radioimmunologically determined. The renin-renin substrate reaction rate followed a saturation kinetics, as it increased the larger the substrate content in the incubation medium until it acquired a maximum value; the reaction rate decreased with substrate concentrations over 40 mg/ml incubation medium. The discontinuance of the renin reaction after incubation by adding acid, boiling and neutralizing again, gave highest renin values. The RIA scattering was 8.3% for double determination of the same sample, for the determination in different RIA additions 7.0%. The detection limit was 20 pg angiotensin I. A direct comparison of radioimmunoassay and bioassay exhibited a very significant agreement of both methods, where the radioimmunologically measured renin values were on average four times larger than those obtained using biological technique. The definition of the so-called normal values for absolute and specific renin concentration in human kidney tissue enabled one to assess the renin values in various syndromes. (orig./MG) [de

  10. Radioimmunoassay in developing countries: General principles

    International Nuclear Information System (INIS)

    Piyasena, R.D.

    1992-01-01

    Radioimmunoassay (RIA) is probably the most commonly performed nuclear medicine technique. It is an in vitro procedure, where no radioactivity is administered to the patient. But this alone is not the reason for its widespread use. It provides the basis for extremely sensitive and specific diagnostic tests, and its use in present day medicine has brought a virtual information explosion in terms of understanding the pathophysiology of many diseases. The fact that the technology involved is within the technical and economic capabilities of the developing world is evident from the increasing demand for its introduction or expansion of existing services. RIA facilities need not be restricted to urban hospitals, as in the case of in vivo nuclear medicine techniques, but may be extended to smaller district hospitals and other laboratories in peripheral areas. It is also possible to send blood samples to a central laboratory so that a single centre can serve a wide geographical area. There are many laboratories in the industrialized world that receive a major proportion of samples for assay by mail. In recent years, substantial RIA services have been established in many of the developing countries in Asia and Latin America. The International Atomic Energy Agency (IAEA) and World Health Organisation (WHO) have made vital contributions to these activities and have played a catalytic role in assisting member states to achieve realistic goals. In the past five years, more than 250 individual RIA laboratories in developing member states have been beneficiaries of IAEA projects

  11. Estimation of urinary angiotensin II by radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Fukuchi, S [Tohoku Univ., Sendai (Japan). School of Medicine

    1974-11-01

    Urine samples were collected from fasting subjects after maintaining posture for 2 hr in early morning. Urinary angiotensin II was extracted with SE-Sephadex. The extracts, after being dissolved in phosphate buffer, pH 7.5, were measured by radioimmunoassay. Recovery, sensitivity and accuracy were found to be satisfactory. The normal values obtained from 6 subjects were 52-280 pg/2 hr. The values were almost normal in essential hypertension and in chronic glomerulonephritis. They were high in 3 out of 6 cases with renovascular hypertension and subsequently dropped after surgery. In 6 cases with primary aldosteronism, very low levels were found. These increased after the removal of adrenal adenomas. No positive correlation between simultaneous plasma and urinary angiotensin samples was apparent. Also no positive correlation between urinary angiotensin and urine volume was found. In renovascular hypertention, during glucose infusion, lower values in urine volume and angiotensin excretion were observed on the stenotic side as compared to the intact side. Thus, the angiotensin excretion rate does not appear to be regulated by arterial angiotensin concentration, but rather by the angiotensin perfusion rate.

  12. Serum erythropoietin levels by radioimmunoassay in polycythaemia

    Energy Technology Data Exchange (ETDEWEB)

    Birgegaard, G.; Miller, O.; Caro, J.; Erslev, A. (Cardeza Foundation for Hematological Research, Jefferson University, Philadelphia, Pa.)

    1982-01-01

    A radioimmunoassay (RIA) method for erythropoietin (Epo) was developed and validated against the polycythaemic mouse assay. The correlation was good, with a r=0.94. Several other criteria of specificity were also filled by the RIA, which had a lower detection limit of 5 mU/ml. The mean serum-Epo level in 6 patients with secondary polycythaemia, 50.2 +- 26.2 mU/ml, was significantly higher than in a group of 11 normal subjects, 28.7 +- 7.2 mU/ml (P<0.0002). However, the Epo level in 31 polycythaemia vera (PV) patients, M = 21.9 +- 6.6 mU/ml, was not significantly different from normal (P = 0.006). Since previous studies with bioassay of heat-treated and concentrated plasma samples have shown a decreased serum-Epo level in PV, Epo levels were measured before and after heat treatment and concentration of samples from normals and polycythaemics. It was found that the levels of immunoreactive material increased after heat treatment and 40 times concentration in samples from normals and patients with secondary polycythaemias, but decreased in PV. We conclude that the Epo levels in serum in the low range measured by our and previous RIA:s probably are not true Epo levels but are partly due to an unspecific serum effect, that was removed by heat treatment.

  13. Radioimmunoassay of creatine kinase BB isoenzyme

    International Nuclear Information System (INIS)

    Geng Jianguo

    1988-01-01

    A radioimmunoassay of creatine kinase BB isoenzyme (CK-BB) was developed by using CK-BB purified from human brain. The CK-BB antiserum was raised by immunizing rabbite and 125 I-CK-BB iodinated with Bolton-Hunter reagent. The affinity constant was 3.0 x 10 9 mol/L. No cross reactions with creatine kinase MM isoenzyme and neuron-specific enolase were found. The measuring range was 3.5 x 10 -8 ∼ 1.2 x 10 -5 mmol/L, the average recovery rate 97.5%, with the inter and intrassay CV 3.1% and 12%, respectively. The average serum CK-BB concentration in 83 normal persons was 1.5 x 10 -7 +- 8.1 x 10 -8 mmol/L, quite different from the values of acute myocardial infarction (5.2 x 10 -6 +- 1.2 x 10 -4 mmol/L, n = 28) and cerebral vascular accident (8.4 x 10 -4 +- 5.0 x 10 -4 mmol/L, n = 10)

  14. Radioimmunoassay of penicilloyl groups in biological fluids

    International Nuclear Information System (INIS)

    Wal, J-M.; Bories, G.

    1975-01-01

    Penicilloyl-protein conjugates may be formed in man or animals after therapeutic treatment but cannot be detected by the classical microbiological assay methods used for penicillin. Allergies have been noted in consumers of products coming from animals treated with penicillin (milk particularly). Although these compounds present a risk to public health, they passed unnoticed through hygienic food inspection. Therefore a specific and sensitive method was devised for the assay of these derivatives in biological fluids where they can be present in trace amounts. An iodine-125 labelled conjugate has been prepared. Already usable for the detection of antipenicilloyl antibodies in sera of penicillin allergic patients, it has been used for the development of a radioimmunoassay of penicilloyl groups. Assay is done directly on milk, urine and serum without previous extraction and with a detection limit of a few ppb. It permits a rapid, specific and easy to handle determination in the sera of hospital patients as well as in the inspection of animal products at the slaughter house and at the dairy

  15. Development of radioimmunoassay for prolactin binding protein

    Energy Technology Data Exchange (ETDEWEB)

    Raikar, R.S.; Sheth, A.R. (Institute for Research in Reproduction, Bombay (India))

    1982-01-01

    Using a homogenous prolactin binding protein (PBP) preparations from rat seminal vesicle secretion, a sensitive and specific radioimmunoassay (RIA) for PBP has been developed. The assay was highly specific and showed no cross-reaction with other protein hormones from various species. The antiserum had an affinity constant (Ka) of 2.66 x 10/sup 10/ M/sup -1/. The assay sensitivity was in the range of 0.5-1.0 ng of pure PBP per assay tube and the intra- and inter-assay coefficients of variations were 6-8% and 12-14.5% respectively. The overall recovery of PBP to the rat seminal vesicle secretion was 96.8%. Using this RIA, PBP levels in various biological fluids and reproductive tissues were measured. Azoospermic human semen contained significantly higher levels of PBP than normospermic semen. The seminal vesicle of rat exhibited the highest concentration of PBP. Administration of antiserum to PBP to mature male rats resulted in a significant reduction in the weight of ventral prostrate and serum prolactin levels were significantly elevated in these animals suggesting that the antibody raised against the PBP was capable of blocking prolactin receptors.

  16. Radioimmunoassay for chlorinated dibenzo-p-dioxins

    International Nuclear Information System (INIS)

    Albro, P.W.; Chae, K.; Luster, M.I.; Mckinney, J.D.

    1980-01-01

    The invention provides a double-antibody radioimmunoassay method for the determination of chlorinated dibenzo-p-dioxins, particularly, 2,3,7,8-tetrachlorodibenzo-p-dioxin, in environmental samples including animal tissues such as monkey liver and adipose tissues. The limit of detection is approximately 25 picograms for 2,3,7,8-tetrachlorodibenzo-pdioxin. Assuming an appropriate cleanup procedure is used, chlorinated dibenzofurans are the only likely interferences, and these can be distinguished through the use of two antisers of different dibenzo-furan/dibenzodioxin selectivities. The invention includes the preparation of a reproducible antigen, an appropriate radiolabeled hapten, and effective sample extracts. A feature of the assay method is the use of a nonionic detergent (e.g., ''cutscum'' or ''triton x-305'') to solubilize the extremely hydrophobic dibenzo-p-dioxins in a manner permitting their binding by antibodies. The immunoassay is applicable to screening samples in order to minimize the demand for mass spectrometric screening, and to routine monitoring for exposure to known chlorinated dibenzo-p-dioxins in potentially contaminated environments

  17. Radioimmunoassay for human health in developing countries

    International Nuclear Information System (INIS)

    Piyasena, R.D.; Airey, P.L.; Ganatra, R.D.; Nofal, M.

    1989-01-01

    Since first introduced in the early 1960s, radioimmunoassay (RIA) has gained wide acceptance as an analytical method adopted by an increasing number of developing countries as an appropriate technology that can be managed within the capabilities of local infrastructures. An informed estimate would be that there are, at present, more than 500 hospitals, university, or other laboratories in the developing world engaged in RIA on some scale. In the developing world, RIA is used primarily for patient management, but research activity is also increasing as expertise and resources improve. The majority of patient samples processed are in relation to thyroid disorders. However, the technique also is used widely in the investigation of other endocrine conditions and public health problems. Some developing countries have gained the capability to perform radioisotopic microassays in areas of clinical and research importance such as steroid receptor quantification in breast tissue; diagnosis of bacterial and parasitic disorders; investigation of infertility and sterility; narcotic drug abuse; and organ transplantation. 1 fig

  18. A simple radioimmunoassay for plasma cortisol

    International Nuclear Information System (INIS)

    Seth, J.; Brown, L.M.

    1978-01-01

    A simple radioimmunoassay (RIA) for plasma cortisol is described which combines the advantages of (i) direct analysis of untreated plasma samples, (ii) use of solid-coupled anti-cortisol antibodies and (iii) use of a gamma-labelled radioligand. The reagents are relatively easily prepared and stable, and the analysis can be completed in 4 h. Inter-assay precision (C.V.) is 8-11%. Critical examination of specificity using high pressure liquid chromatography showed that 23-35% of the immunoassayable material in plasma was not cortisol. RIA results on samples collected under basal conditions were an average 40 nmol/l lower than fluorimetric results, while in insulin hypoglycaemia and synacthen (ACTH) stimulation tests, this difference increased to over 100 nmol/l. The RIA is technically more simple than fluorimetric, competitive-protein-binding, and many RIA methods, and can be used with advantage in the routine investigation of adrenocortical function. However, using the present antiserum, the RIA is not applicable to investigations on patients receiving metyrapone, nor in suspected cases of congenital adrenal hyperplasia. (Auth.)

  19. Steroid radioimmunoassays. The problems of blanks

    Energy Technology Data Exchange (ETDEWEB)

    Shinde, Y; Hacker, R R; Ntunde, B; Smith, V G [Guelph Univ., Ontario (Canada). Dept. of Animal and Poultry Science

    1981-06-01

    An estrogen radioimmunoassay was used to study the problem of blanks in steroid assays. Negligible binding (1.5 percent) in the non-antibody tubes prevailed throughout the study. The assay was validated using accepted procedures. Both water and solvent blanks had estrogen concentrations of 7-9 pg/tube. However, neither water nor solvent blanks showed a dose-related response, indicating that they were 'real' blanks. Exogenous estradiol, when added to water and solvent in quantities less than the estimated blank, was not quantitatively recovered. However, exogenous estradiol added to the water solvent in quantities greater than the blank estimate was quantitatively recovered. The sensitivity of the reference standard curve was 6-10 pg/tube, approximately the same as the blank estimate. These results indicated that the estimates of water and solvent blanks were measures of the assay sensitivity. In such circumstances, it is suggested that blank estimates should not be subtracted from sample values. If the blank estimates are high, attention should be directed towards improving the sensitivity of the assay.

  20. Parathyroid hormone: radioimmunoassay and clinical interpretation

    International Nuclear Information System (INIS)

    Hawker, C.D.

    1975-01-01

    A radioimmunoassay for serum immunoreactive parathyroid hormone (iPTH), which has had widespread clinical use for five years, is described in detail. The iPTH results in large groups of patients are reported, and are discussed in relation to the specificity of the assay and in relation to other assays. The assay has excellent precision and is highly proficient in discrimination of groups of patients. Ninety-three percent of 412 patients with surgically proven primary hyperparathyroidism were confidently separated from normal subjects or patients with hypercalcemia owing to other causes, while 86 percent of 160 patients with chronic renal failure and secondary hyperparathyroidism had iPTH values more than 2 S.D. above the normal mean. Results in patients with ectopic hyperparathyroidism were lower than in primary hyperparathyroidism although these groups showed considerable overlap. The antiserum used in this assay for iPTH appears to be specific for the carboxy-terminal region of the secreted or intact form of PTH but recognizes predominantly the secreted form rather than carboxy-terminal fragments believed to be in the circulation. It does not recognize amino terminal fragments. The assay is useful in selective venous catheterization for preoperative localization of hyperfunctioning parathyroid tissue

  1. Thermal conductivity of newspaper sandwiched aerated lightweight concrete panel

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Soon-Ching; Low, Kaw-Sai [Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Jalan Genting Kelang, Setapak, 53300 Kuala Lumpur, Wilayah Persekutuan (Malaysia)

    2010-12-15

    Investigation on the thermal conductivity of newspaper sandwiched aerated lightweight concrete (ALC) panels is the main purpose of this study. Various densities of ALC panels ranging from 1700, 1400 and 1100 kg/m{sup 3} with three different aerial intensities of newspaper sandwiched were produced. Investigation was limited to the effect of aerial intensity of newspaper sandwiched and the effect of density of ALC on thermal conductivity. It is found that the thermal conductivity of newspaper sandwiched ALC panels reduced remarkably compared to control ALC panels. The reduction was recorded at 18.0%, 21.8% and 20.7% correspond to densities of 1700, 1400 and 1100 kg/m{sup 3} with just a mere 0.05 g/cm{sup 2} aerial intensity of newspaper sandwiched. Newspaper sandwiched has a significant impact on the performance of thermal conductivity of ALC panels based on regression analysis. (author)

  2. One-site versus two-site phacotrabeculectomy: a prospective randomized study

    Directory of Open Access Journals (Sweden)

    Moschos MM

    2015-08-01

    Full Text Available Marilita M Moschos,1 Irini P Chatziralli,2 Michael Tsatsos3 1First Department of Ophthalmology, University of Athens, 2Second Department of Ophthalmology, Ophthalmiatrion Athinon, Athens, Greece; 3Department of Ophthalmology, Cambridge University Hospital NHS, Cambridge, UK Purpose: The purpose of this study is to compare the efficacy and safety of one-site and two-site combined phacotrabeculectomy with foldable posterior chamber intraocular lens implantation.Methods: Thirty-four patients (41 eyes with glaucoma and cataract were randomly assigned to undergo either a one-site (22 eyes or a two-site (19 eyes combined procedure. One-site approach consisted of a standard superior phacotrabeculectomy with a limbus-based conjunctival flap, while two-site approach consisted of a clear cornea phacoemulsification and a separate superior trabeculectomy with a limbus-based conjunctival flap.Results: Mean follow-up period was 54 months (standard deviation [SD] 2.3. Mean preoperative intraocular pressure (IOP in the one-site group was 21.3 mmHg (SD 2.8 and in the two-site group was 21.8 mmHg (SD 3.0 (P>0.1. Mean postoperative IOP significantly decreased in both groups compared to the preoperative level and was 15.6 mmHg (SD 3.5 in the one-site group and 14.9 mmHg (SD 2.7 in the two-site group. Three months later, the difference between the two groups was not statistically significant (P=0.058. The one-site group required significantly more medications than the two-site group (P=0.03. Best-corrected visual acuity (BCVA improved similarly in both groups, but there was less postoperative (induced astigmatism in the two-site group in a marginal statistical level (P=0.058. Intra- and postoperative complications were comparable in the two groups.Conclusion: Both techniques yielded similar results concerning final BCVA and IOP reduction. However, the two-site group had less induced astigmatism and a better postoperative IOP control with less required

  3. Immunodiagnosis of opportunistic mycoses: detection of fungal antigenemia by radioimmunoassays in systemic candidiasis and aspergillosis

    International Nuclear Information System (INIS)

    Weiner, M.H.

    1980-01-01

    The authors have developed radioimmunoassays to the Candida carbohydrate, mannan, and to an Aspergillus cell wall carbohydrate. They evaluate these radioimmunoassays with sera from rabbit models of disseminated mycoses, and further evaluate the radioimmunoassays for their diagnostic usefulness in a panel of patient sera. (Auth.)

  4. Creep of sandwich beams with metallic foam cores

    International Nuclear Information System (INIS)

    Kesler, O.; Crews, L.K.; Gibson, L.J.

    2003-01-01

    The steady state creep deflection rates of sandwich beams with metallic foam cores were measured and compared with analytical and numerical predictions of the creep behavior. The deflection rate depends on the geometry of the sandwich beam, the creep behavior of the foam core and the loading conditions (stress state, temperature). Although there was a considerable scatter in the creep data (both of the foams and of the sandwich beams made using them), the data for the sandwich beams were fairly well described by the analysis

  5. Creep of sandwich beams with metallic foam cores

    Energy Technology Data Exchange (ETDEWEB)

    Kesler, O.; Crews, L.K.; Gibson, L.J

    2003-01-20

    The steady state creep deflection rates of sandwich beams with metallic foam cores were measured and compared with analytical and numerical predictions of the creep behavior. The deflection rate depends on the geometry of the sandwich beam, the creep behavior of the foam core and the loading conditions (stress state, temperature). Although there was a considerable scatter in the creep data (both of the foams and of the sandwich beams made using them), the data for the sandwich beams were fairly well described by the analysis.

  6. Damage Tolerance of Resin Transfer Molded Composite Sandwich Constructions

    National Research Council Canada - National Science Library

    Vaidya, U

    1999-01-01

    .... The sandwich composite concepts considered in this study possessed the feasibility to improve the transverse stiffness, provide enhanced damage resistance/tolerance to impact and functionality...

  7. Low Velocity Impact Properties of Aluminum Foam Sandwich Structural Composite

    Directory of Open Access Journals (Sweden)

    ZHAO Jin-hua

    2018-01-01

    Full Text Available Sandwich structural composites were prepared by aluminum foam as core materials with basalt fiber(BF and ultra-high molecular weight polyethylene(UHMWPE fiber composite as faceplate. The effect of factors of different fiber type faceplates, fabric layer design and the thickness of the corematerials on the impact properties and damage mode of aluminum foam sandwich structure was studied. The impact properties were also analyzed to compare with aluminum honeycomb sandwich structure. The results show that BF/aluminum foam sandwich structural composites has bigger impact damage load than UHMWPE/aluminum foam sandwich structure, but less impact displacement and energy absorption. The inter-layer hybrid fabric design of BF and UHMWPE has higher impact load and energy absorption than the overlay hybrid fabric design faceplate sandwich structure. With the increase of the thickness of aluminum foam,the impact load of the sandwich structure decreases, but the energy absorption increases. Aluminum foam sandwich structure has higher impact load than the aluminum honeycomb sandwich structure, but smaller damage energy absorption; the damage mode of aluminum foam core material is mainly the fracture at the impact area, while aluminum honeycomb core has obvious overall compression failure.

  8. Radioimmunoassay for tumor antigen of human cervical squamous cell carcinoma

    International Nuclear Information System (INIS)

    Kato, H.; Torigoe, T.

    1977-01-01

    A heterologous antiserum for human cervical squamous cell carcinoma was prepared and specificity determined by Ouchterlony immunodiffusion and immunofluorescence studies. With this antiserum, a tumor antigen was purified from human cervical squamous cell carcinoma tissue. The specificities of the antigen and the antiserum were then re-examined by a radioimmunoassay method using 125 I-labeled purified antigen. Although normal cervical tissue extract showed a moderate cross-reactivity in the radioimmunoassay, the circulating antigen activity could not be detected in normal women or in several patients with other carcinomas, whereas 27 of 35 patients with cervical squamous cell carcinoma showed detectable serum antigen activity. All patients with advanced stages of cervical squamous cell carcinoma showed detectable antigen levels. These results indicate that there is a quantitative abnormality, at least, of this tumor antigen in patients with cervical squamous cell carcinoma and that the radioimmunoassay for the antigen is a potentially useful tool in clinical care

  9. Determination of triiodothyronine in serum by enzyme- and radioimmunoassay

    International Nuclear Information System (INIS)

    Oellerich, M.; Haindl, H.; Medizinische Hochschule Hannover

    1981-01-01

    An evaluation of a heterogeneous enzyme immunoassay for determination of triiodothyronine in serum (Enzymun-Test T 3 , Boehringer Mannheim) is presented. The enzyme immunoassay was compared with the laboratory routine radioimmunoassay. The precision of both assays was satisfactory at triiodothyronine concentrations between 1.0 and 8.0 nmol/l (coefficients of variation from day to day 3 from 96-104% and with the radioimmunoassay from 88-111%. A comparison of the results obtained by Enzymun-Test T 3 and the radioimmunoassay in a series of 103 patients showed a good correlation between both methods. L-thyroxine did not cause a relevant cross-reaction in the enzyme immunoassay. About 20 unknown samples can be analyzed in triplicate by Enzymun-Test T 3 within 260 minutes. (orig.) [de

  10. Estimation of antibodies to human cytomegalovirus by immunofluorescence and radioimmunoassay

    International Nuclear Information System (INIS)

    Jankowski, M.; Gut, W.; Nawrocka, E.

    1980-01-01

    The 125 I labelled IgG fraction against rabbit IgG of goat origin was employed for the detection of CMV IgG and IgM antibodies in the double indirect radioimmunoassay. The results were compared with those obtained in complement fixation, indirect immunofluorescence and anti-complement immunofluorescence tests. The application of labelled anti-fc antisera, instead of antisera against whole IgG in the tests for detection of specific CMV IgG antibody resulted in increased sensitivity of radioimmunoassay and reduction of non-specific cytoplasmatic reactions in preparations stained by indirect immunofluorescence. The absorption of sera with protein A rich staphylococci and aggregates to immunoglobulin eliminated unwanted secondary IgM staining caused by rheumatoid factors both in indirect immunofluorescence and radioimmunoassay tests for CMV antibodies. (author)

  11. Radioimmunoassay for pantothenic acid in blood and other tissues

    International Nuclear Information System (INIS)

    Wyse, B.W.; Wittwer, C.; Hansen, R.G.

    1979-01-01

    We described a radioimmunoassay for pantothenic acid in biological tissues. D-Pantothenic acid was conjugated with bovine serum albumin by use of a bromoacetyl derivative of pantothenic acid, and antibody to this antigen was raised by injecting it into the foot pads of rabbits. For the radioimmunoassay, a 100-fold dilution of the resulting antiserum was incubated with radiolabeled panthothentic acid. The antibodies were precipitated and dissolved, and the radioactivity of the solution was measured in a liquid scintillation counter. Between 5 and 125 ng of pantothenic acid can be detected in 75 μL of tissue extract. Validation included recovery and precision studies, parallelism with tissue extracts, and competitive binding studies. Results of the radioimmunoassay and those of microbiological assay with use of Lactobacillus plantarum correlated well

  12. Transmission loss optimization in acoustic sandwich panels

    Science.gov (United States)

    Makris, S. E.; Dym, C. L.; MacGregor Smith, J.

    1986-06-01

    Considering the sound transmission loss (TL) of a sandwich panel as the single objective, different optimization techniques are examined and a sophisticated computer program is used to find the optimum TL. Also, for one of the possible case studies such as core optimization, closed-form expressions are given between TL and the core-design variables for different sets of skins. The significance of these functional relationships lies in the fact that the panel designer can bypass the necessity of using a sophisticated software package in order to assess explicitly the dependence of the TL on core thickness and density.

  13. Failure modes of composite sandwich beams

    Directory of Open Access Journals (Sweden)

    Gdoutos E.

    2008-01-01

    Full Text Available A thorough investigation of failure behavior of composite sandwich beams under three-and four-point bending was undertaken. The beams were made of unidirectional carbon/epoxy facings and a PVC closed-cell foam core. The constituent materials were fully characterized and in the case of the foam core, failure envelopes were developed for general two-dimensional states of stress. Various failure modes including facing wrinkling, indentation failure and core failure were observed and compared with analytical predictions. The initiation, propagation and interaction of failure modes depend on the type of loading, constituent material properties and geometrical dimensions.

  14. TRH radioimmunoassay for unextracted human urine

    International Nuclear Information System (INIS)

    Mitsuma, Terunori; Hirooka, Yoshibumi; Nihei, Noriyuki

    1975-01-01

    The authors developed a TRH radioimmunoassay for unextracted human urine using anti-TRH antibody produced by immunization of rabbits with a TRH-bis-diazotized-bovine serum albumin conjugate. The antibody had no crossreactivity with TRH analogues, amino acids or pituitary hormones, but with L or DL-Aze3-TRH. TRH was radioiodinized by Greenwood-Hunter's method, followed by purification on Sephadex G-10. Inactivation of TRH by serum was well documented. The authors found however that this inactivation of TRH could be prevented by adjusting the pH to 3.0 or by keeping the temperature between 4 0 C and -20 0 C. All assay procedures were performed in 0.01 M phosphate buffer with 0.15 M NaCl (pH 7.5) at 4 0 C. Free and bound forms were separated with a second antibody system. In this system, sensitivity was 0.01 ng/tube, recovery was approximately 100%, intrassay reproducibility was 3.2% and interassay variation was 9.8%. TRH levels in urine measured with this system were undetectable to 9.0 ng/ml in normal subjects, undetectable in hyperthyroid patients or a tertiary hypothyroid patient and 13 to 24 ng/ml in primary hypothyroid patients. Approximately 6 percent of the intravenously administered TRH was excreted into the urine within 12 hours following administration in a normal subject. As a result this assay system is quite attractive for clinical determination as well as research application. (Evans, J.)

  15. Oxytocin determination by radioimmunoassay in cattle. 1

    International Nuclear Information System (INIS)

    Schams, D.; Schmidt-Polex, B.; Kruse, V.

    1979-01-01

    A radioimmunoassay for oxytocin in cow plasma is described. Antisera were raised in rabbits against synthetic oxytocin coupled to bovine thyroglobulin. Iodinated oxytocin free of unlabelled oxytocin and most likely also free of diiodo-oxytocin was used as radioactive tracer. The tracer showed a high degree of purity, and was stable on storage. It could be used in the assay for 2-3 months. The assay showed very little cross-reactivity with vasopressin. Acetone was used for the extraction of oxytocin from plasma as well as from standards made of synthetic exytocin in pooled cow plasma. Inhibition curves obtained with plasma collected from cows at parturition were parallel to those obtained with the oxytocin standard preparation. The mean recovery of oxytocin added to cow plasma was 106% (SD=14). The within-assay coefficient of variation (CV) varied from 5.2 to 10.9%, and the between-assay CV was in the order of 13%. The assay sensitivity was 1 pg (0.5 μU) per tube, corresponding to 3 pg/ml plasma. Around the time of milking the plasma oxytocin profile showed a strong response to the preparation for milking, and a further effect related to the attachment of the teat cups of the milking machine. Peak concentrations were in the range of 15-50 pg/ml. During parturition there was a peak of oxytocin (65 pg/ml) coinciding with the expulsion phase. After this peak levels decreased by remained measurably elevated until the expulsion of the placenta. The plasma disappearance curve for immunoreactive oxutocin after the infusion of 100 IU oxytocin over a period of 1 h showed two components with apparent half-lives of 7-9 and 25 min, respectively. (author)

  16. Radioimmunoassay of thyrotropin concentrated from serum

    International Nuclear Information System (INIS)

    Nisula, B.C.; Louvet, J.P.

    1978-01-01

    A method for concentrating human TSH (hTSH) from serum for use in RIAs is described. The method takes advantage of the affinity of the plant lectin, concanavalin A, for the carbohydrate portion of the hTSH molecule. The hTSH from 2.5 ml serum was adsorbed to concanavalin A covalently linked to sepharose and then radioimmunoassayed using the hTSH antiserum and hTSH for iodination distributed by the National Pituitary Agency. For the RIA standard curve, the hTSH reference preparation was concentrated from a serum wwith undetectable hTSH in order to correct for recovery and to control for nonspecific effects. The percentage of serum hTSH extracted from 2.5 ml serum with the concentration procedure was 76.6 +- 3.4% (mean +- SD). The coefficient of correlation between serum hTSH, determined with the concentration procedure, and serum hTSH determined without was 0.979 (P < 0.001). Over 95% of normal adult men and women had detectable levels of serum hTSH, ranging from < 0.56 to 4.0 μU/ml. The mean of detectable serum hTSH levels in normal adult women (n = 11) was 1.54 +- 1.03 μU/ml (mean +- SD) and in normal men (n = 9) was 2.02 +- 1.15 μU/ml (mean +- SD). Clinically hyperthyroid patients with diffuse and nodular toxic goiters (n = 8) and patients with hypothyroidism secondary to pituitary disease (n = 6), four of whom were taking replacement doses of thyroid hormone, had undetectable serum hTSH levels. Serum hTSH in patients with primary hypothyroidism uniformly exceeded the normal range. This hTSH concentrating procedure enhances the effective sensitivity and, therefore, the clinical utility of the RIA for hTSH in serum

  17. Problems in radioimmunoassay of human lutropin with commercially available regents

    International Nuclear Information System (INIS)

    Hammond, J.E.; Phillips, J.C.; Straight, C.B.; Hammond, M.G.

    1980-01-01

    To evaluate five commercially available reagent sets supplied for the radioimmunoassay of lutropin, we determined whether there was parallelism between the curve given by dilutions of the standards supplied by the manufacturers, by dilutions of a serum pool, and by dilutions of a standard preparation from human pituitaries, LER-907. These studies demonstrated significant analytical problems with three of the five sets. We conclude that each user should carefully evaluate all commercially available radioimmunoassays for lutropin (and, by inference, for other peptide hormones) before use

  18. A sensitive radioimmunoassay for a component of mouse casein

    International Nuclear Information System (INIS)

    Enami, Jumpei; Nandi, S.; California Univ. Berkeley

    1977-01-01

    Mouse casein (m.w. 22,000 daltons) has been purified by employing Sephadex G-100 and DEAE-cellulose column chromatographies. A sensitive radioimmunoassay method has been developed by using [ 125 I]-labelled casein and antiserum elicited in rabbits after injection of glutaraldehyde-treated casein. The assay method is capable of detecting as little as 0.1 ng of casein. The use of the present radioimmunoassay method in detecting casein production in cultured mouse mammary explants has also been demonstrated

  19. Radioimmunoassay of type D oncovirus from continuous J-96 cells

    International Nuclear Information System (INIS)

    Vlasenkova, N.K.; Altshtejn, A.D.; Zhdanov, V.M.; Kitsak, V.Ya.

    1978-01-01

    The radioimmunoassay of the J-96 virus and an extract of J-96 cells in the homologous and heterologous systems aimed at detecting antigenic determinants of p25 of Mason-Pfizer virus and group-specific and interspecies antigenic determinants p30 of Rauscher leukaemia virus demonstrated that (1) J-96 virus contains a major internal protein immunologically identical with p25 protein of Mason-Pfizer virus based on the antigenic determinants detectable by the radioimmunoassay used; and (2) no interspecies antigenic determinants characteristic of the major internal protein of mammalian type C viruses were detectable in the J-96 virus or the J-96 cell extract. (author)

  20. A double antibody radioimmunoassay specific for placental alkaline phosphatase

    International Nuclear Information System (INIS)

    Dass, S.; Bagshawe, K.D.

    1984-01-01

    Placental alkaline phosphatase (PLAP) is normally found in enzymically measurable amounts in second and third trimester pregnancy serum. Its occurrence in sera and tumours from patients with malignant disease has led to the development of methods to specifically identify and quantitate the enzyme. Recently immunological techniques have been used, employing antibodies raised to purified PLAP; these include solid phase radioimmunoassays and enzyme-immunoassay. The development of a sensitive, specific, automated double-antibody radioimmunoassay for the measurement of PLAP in serum is reported. (Auth.)

  1. Development and application of radioimmunoassays for vitamin D metabolites

    International Nuclear Information System (INIS)

    Clemens, T.L.

    1980-04-01

    A sensitive radioimmunoassay for 1,25-dihydroxycholecalciferol, the most potent derivative of vitamin D 3 is described and has been used to measure its concentration in human serum from normal subjects, patients with clinical osteomalacia,, anephric patients and those with chronic renal failure. The absorption and clearance of 1,25-dihydroxycholecalciferol have been studied in healthy and uremic patients by following the changes of its circulating concentration after administration of a single (2ug) dose of synthetic 1,25-dihydroxycholecalciferol orally. The radioimmunoassay was also used to investigate the underlying cause of the hypercalcaemia of sarcoidosis. (author)

  2. Testing of the scintillation sandwich prototype

    International Nuclear Information System (INIS)

    Vashkevich, V.

    1995-06-01

    The 3 m 2 prototype of the surface detector using optical fiber readout was completely prepared for testing measurements in February 1995 at Fermilab. Two 25 mm thick, 3 m 2 acrylic scintillation plates (1.2 x 2.5 m 2 ) are used for light collection in the upper (above the 25 mm steel plate) and lower (below the steel) counters of the sandwich. The light is collected with the help of 1 mm diameter wavelength shifter fiber loops 3 m long inserted in the grooves on the top surface of the scintillator, 3 fibers per groove. We used Kurary Y11, 200 ppm of shifter dye, and double clad fibers. 1.5 m of clear fibers spliced to each end of the shifter fiber transport the light to the phototube. Spacing between the grooves is 5 cm. The counter's edges were painted with BICRON (BC620) white reflective paint. The scintillation plates were wrapped with Dupont Tyvek. The glued bundle of fibers is connected to an EMI-9902KB 38 mm phototube through the simple light mixer bar. Used PM has a ''green extended'' rubidium bialkali photocathode. The report contains information on the testing of the scintillation sandwich

  3. Dynamic Failure of Composite and Sandwich Structures

    CERN Document Server

    Abrate, Serge; Rajapakse, Yapa D S

    2013-01-01

    This book presents a broad view of the current state of the art regarding the dynamic response of composite and sandwich structures subjected to impacts and explosions. Each chapter combines a thorough assessment of the literature with original contributions made by the authors.  The first section deals with fluid-structure interactions in marine structures.  The first chapter focuses on hull slamming and particularly cases in which the deformation of the structure affects the motion of the fluid during the water entry of flexible hulls. Chapter 2 presents an extensive series of tests underwater and in the air to determine the effects of explosions on composite and sandwich structures.  Full-scale structures were subjected to significant explosive charges, and such results are extremely rare in the open literature.  Chapter 3 describes a simple geometrical theory of diffraction for describing the interaction of an underwater blast wave with submerged structures. The second section addresses the problem of...

  4. Single versus Two-Site Phacoemulsification and Mitomycin-C Trabeculectomy

    Directory of Open Access Journals (Sweden)

    Alireza Baradaran-Rafiee

    2008-11-01

    Full Text Available

    PURPOSE: To compare the outcomes of single-site versus two-site mitomycin-C (MMC augmented phacotrabeculectomy. METHODS: This matched randomized clinical trial included 34 eyes of 30 patients with visually significant cataracts and poorly controlled glaucoma. Equal numbers of eyes were randomly assigned to the single-site and two-site groups. In the single-site approach, phacoemulsification was performed under a superior scleral tunnel followed by trabeculectomy. The two-site approach included a temporal clear corneal phaco-emulsification combined with a separate superior trabeculectomy. MMC 0.2 mg/ml was similarly applied for one minute in both groups. RESULTS: Patients were followed for a mean period of 13±1.4 (range, 12 to 15 months. Mean best corrected visual acuity one year after surgery was 0.6±0.4 LogMAR in the single-site group and 0.4±0.28 LogMAR in the two-site group (P=0.12. In the single-site group, mean preoperative intraocular pressure (IOP was 26.4±6.6 mmHg which was decreased to 14.8±2.5 mmHg, one year after the operation (P < 0.001. Corresponding figures for the two-site group were 22.9±3.3 and 13.6±1.7 mmHg respectively (P < 0.001. At final follow up no significant difference in IOP existed between the study groups. Mean number of anti-glaucoma medications was 0.06±0.24 in the two-site group vs 0

  5. Logistics of national radioimmunoassay services and radioimmunoassay trouble shooting in developing countries

    International Nuclear Information System (INIS)

    Hazra, D.K.; Shukla, A.K.; Arvind, B.; Khandelwal, S.; Singh, R.; Lahiri, V.L.

    1986-01-01

    The logistics of national radioimmunoassay services are analysed in regard to: applications of immunoassays in developing countries; provision of matched reagents; collection, storage and transport of patient samples, particularly from rural areas; development of robust new immunoassay systems, especially those using non-isotopic labels; quality control; and interrelation with international agencies and commercial suppliers. The effect of using different methods and temperatures of sample storage on representative glycoprotein, steroid, thyroid and communicable disease analytes is examined. The need for stratification of assay services (district, state and national/regional levels) for various tests is discussed in relation to their clinical urgency. A trouble shooting guide suited to developing countries has been written. Starting from various symptoms of assay failure, it describes the differential diagnosis of likely causes, lists appropriate tests to confirm the diagnosis and finally suggests remedial action to prevent future similar mishaps or to salvage the assay. (author)

  6. Non-linear Behavior of Curved Sandwich Panels

    DEFF Research Database (Denmark)

    Berggreen, Carl Christian; Jolma, P.; Karjalainen, J. P.

    2003-01-01

    In this paper the non-linear behavior of curved sandwich panels is investigated both numerically and experimentally. Focus is on various aspects of finite element modeling and calculation procedures. A simply supported, singly curved, CFRP/PVC sandwich panel is analyzed under uniform pressure loa...

  7. The sandwich sign | Mahomed | SA Journal of Radiology

    African Journals Online (AJOL)

    The sandwich sign refers to the sandwiching of mesenteric vessels and fat by enlarged mesenteric nodes on cross-sectional imaging, commonly occurring in lymphoma, but not specific to lymphoma. The sign is radiologically indistinguishable from post-transplant lymphoproliferative disorders. The radiological significance ...

  8. Measuring Cohesive Laws for Interfaces in Sandwich Structures

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Sørensen, Bent F.; Berggreen, Carl Christian

    2006-01-01

    mixities. The sandwich specimens consists of glass fiber faces and Divinycell H200 foam core with a pre-crack between face and core made with teflon film. Arbitrary stiffening of the sandwich faces with steel bars adhered to the faces reduces rotations and ensures that the method is useable for a wide...

  9. Design Analysis of the Mixed Mode Bending Sandwich Specimen

    DEFF Research Database (Denmark)

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, Leif A.

    2010-01-01

    A design analysis of the mixed mode bending (MMB) sandwich specimen for face–core interface fracture characterization is presented. An analysis of the competing failure modes in the foam cored sandwich specimens is performed in order to achieve face–core debond fracture prior to other failure modes...... for the chosen geometries and mixed mode loading conditions....

  10. Application of Load Carrying Sandwich Elements in Wind Turbine Blades

    DEFF Research Database (Denmark)

    Jensen, Jacob Fisker; Schultz, Jacob Pagh; Berggreen, Carl Christian

    2005-01-01

    The present work investigates the possibilities and drawbacks when applying sandwich as opposed to single skin composites in the flanges of the load carrying spar in a future 180 m wind turbine rotor. FEA is applied to investigate two basic designs with single skin and sandwich flanges respectively...

  11. Design and manufacturing of bio-based sandwich structures

    CSIR Research Space (South Africa)

    John, Maya J

    2017-03-01

    Full Text Available The aim of this chapter is to discuss the design and manufacturing of bio-based sandwich structures. As the economic advantages of weight reduction have become mandatory for many advanced industries, bio-based sandwich panels have emerged...

  12. Establishment of an indirect solid phase radioimmunoassay for the detection of HSV-type I-specific antibodies in human serum

    International Nuclear Information System (INIS)

    Buchow, H.

    1982-01-01

    An indirect solid phase radioimmunoassay (IFRIA) was developed for the detection in human serum of antibodies against Herpes simplex virus (HSV) type I. The IFRIA was carried out according to the 'sandwich' principle. In comparison to other serological routine methods, especially the complement binding reaction (CBR) commonly used for HSV diagnostic, the IFRIA excelled by being a test which is quick to carry out and by lacking the subjectivity by the researcher in the evaluation of the test results, as well as by the use of patients serum which had not been previously treated. Comparative studies between IFRIA and CBR resulted in no agreement between the respectively attained maximum titer. As a reason for this the different qualities of the antibodies which can be determined by each test were discussed. For the addition of this test to the routine diagnostic further studies in the preservation of the specificity of the antigen in the case of longer storage are requisite. (orig.) [de

  13. Two-site immunoradiometric assay for the MB isoenzyme of creatine kinase

    Energy Technology Data Exchange (ETDEWEB)

    Willson, V J.C.; Jones, H M; Thompson, R J [Cambridge Univ. (UK). Clinical School

    1981-06-18

    A two-site immunoradiometric assay for myocardial creatine kinase MB isoenzyme is described. The method utilizes immobilized anti-human creatine kinase BB antibodies and /sup 125/I-labelled anti-human creatine kinase MM antibodies and can specifically detect creatine kinase MB in the presence of approximately 1000-fold excess of creatine kinase MM or BB. Native kinase MB prepared from human heart and creatine kinase MB prepared by hybridisation of purified human creatine kinase MM and creatine kinase BB appeared to react identically in the assay. Serum estimations on patients with suspected myocardial infarction correlated with the presence of MB band on electrophoresis but preliminary results suggest that the two-site immunoradiometric assay may be more sensitive.

  14. A two-site immunoradiometric assay for the MB isoenzyme of creatine kinase

    International Nuclear Information System (INIS)

    Willson, V.J.C.; Jones, H.M.; Thompson, R.J.

    1981-01-01

    A two-site immunoradiometric assay for myocardial creatine kinase MB isoenzyme is described. The method utilizes immobilized anti-human creatine kinase BB antibodies and 125 I-labelled anti-human creatine kinase MM antibodies and can specifically detect creatine kinase MB in the presence of approximately 1000-fold excess of creatine kinase MM or BB. Native kinase MB prepared from human heart and creatine kinase MB prepared by hybridisation of purified human creatine kinase MM and creatine kinase BB appeared to react identically in the assay. Serum estimations on patients with suspected myocardial infarction correlated with the presence of MB band on electrophoresis but preliminary results suggest that the two-site immunoradiometric assay may be more sensitive. (Auth.)

  15. Two-site Hubbard molecule with a spinless electron-positron pair

    KAUST Repository

    Cossu, Fabrizio

    2012-12-19

    We determine the eigenvalues of the two-site Hubbard molecule with one electron and one positron to describe the characteristics of electron-positron interactions in solids. While the effect of hopping is, in general, opposite to the effect of on-site interaction, we find a complex scenario for the electron-positron pair with a non-vanishing potential drop. We give analytical solutions and discuss the combined effects of the model parameters.

  16. Two-site Hubbard molecule with a spinless electron-positron pair

    KAUST Repository

    Cossu, Fabrizio; Schuster, Cosima; Schwingenschlö gl, Udo

    2012-01-01

    We determine the eigenvalues of the two-site Hubbard molecule with one electron and one positron to describe the characteristics of electron-positron interactions in solids. While the effect of hopping is, in general, opposite to the effect of on-site interaction, we find a complex scenario for the electron-positron pair with a non-vanishing potential drop. We give analytical solutions and discuss the combined effects of the model parameters.

  17. Two site spin correlation function in Bethe-Peierls approximation for Ising model

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, D [Roorkee Univ. (India). Dept. of Physics

    1976-07-01

    Two site spin correlation function for an Ising model above Curie temperature has been calculated by generalising Bethe-Peierls approximation. The results derived by a graphical method due to Englert are essentially the same as those obtained earlier by Elliott and Marshall, and Oguchi and Ono. The earlier results were obtained by a direct generalisation of the cluster method of Bethe, while these results are derived by retaining that class of diagrams , which is exact on Bethe lattice.

  18. Determination of the range of control limits in radioimmunoassay measurements

    International Nuclear Information System (INIS)

    Fiori, A.M.C.

    1981-01-01

    A grouping technique is proposed for control limits in radioimmunoassay measurements. It has the advantage of working with control limits of 99.7% without the inconvenience of the confidence intervals. The method is practical and simple. It provides considerable flexibility for the processing of data. As the number of samples increases, the control limits become better defined. (author) [es

  19. A New Application for Radioimmunoassay: Measurement of Thermodynamic Constants.

    Science.gov (United States)

    Angstadt, Carol N.; And Others

    1983-01-01

    Describes a laboratory experiment in which an equilibrium radioimmunoassay (RIA) is used to estimate thermodynamic parameters such as equilibrium constants. The experiment is simple and inexpensive, and it introduces a technique that is important in the clinical chemistry and research laboratory. Background information, procedures, and results are…

  20. Present status and future possibilities of radioimmunoassay in animal production

    International Nuclear Information System (INIS)

    Karg, H.; Claus, R.; Hoffmann, B.; Schallenberger, E.; Schams, D.

    1976-01-01

    Radioimmunoassays and related isotope techniques have provided new possibilities in hormone analysis. Because of the new dimensions of sensitivity (nanogram and picogram range) it became possible to elucidate for many hormones their levels in peripheral blood plasma. Since some steps of the assay procedures could be automatized, and the evaluation computerized, the efficiency (for example, it is possible to run several thousand determinations weekly in one laboratory) can hardly be equalled by non-isotopic hormone analysis techniques. In animal husbandry the technique can be applied to mapping of physiological phenomena, diagnostic approaches in clinics, control of bio-techniques, residue studies of exogenous hormones, and attempts to use hormonal parameters as guide lines in connection with breeding programmes. The discovery that progesterone levels in milk reflect the corpus luteum function introduced far-reaching radioimmunoassay (RIA) application for fertility control under field conditions. With some other hormones, results of single determinations only allow limited interpretation because of different dynamics, for example releasing pattern, short-term (episodic, diurnal) and long-term (seasonal) variations and clearance properties. Furthermore, questions concerning the interactions between the actual plasma level of the hormone determined and the receptor sites in the target organ have to be solved. There are still gaps concerning the development of radioimmunoassays for important hormones. At present and in the foreseeable future of endocrinology in animal production, radioimmunoassays are indispensible. (author)

  1. Radioimmunoassay for colchicine: synthesis and properties of three haptens.

    Science.gov (United States)

    Pontikis, R; Scherrmann, J M; Nguyen, H N; Boudet, L; Pichat, L

    1980-01-01

    For the development of radioimmunoassay procedures for colchicine, three haptens, N-ethylamino-colchiceinamide, 4-formylchochicine - (O-carboxymethyl) oxime and 4-hydroxymethylcolchicine O-hemisuccinic acid were synthetized and characterized by mass and proton magnetic resonance spectrometries. The conjugates obtained by coupling the haptens to bovine serum albumin were employed to immunize rabbits and goats.

  2. Development of a radioimmunoassay of tetracycline and its derivatives

    International Nuclear Information System (INIS)

    Zitzewitz, A. von.

    1981-01-01

    A radioimmunoassay for tetracycline was developed in the context of the present work. The determination of tetracycline content in biological samples is to be made valid using tetracycline RIA. As well as the carbodiimide method, a by radioimmunologists extremely seldomly used way involving a condensation reaction between protein and haptene via the Mannich reaction was successfully applied. Antibodies were produced using a conventional immunisation method after Abraham, the other applied alternative method after Vaitukaitis et al. The general working methods had to be adapted to the tetracycline RIA. All variable parameters of the antigen-antibody bond were tested to optimize the incubation conditions of the system as well as to control the tracer for a degradation. The detection limit of RIA is 10 - 12 , the measuring range from 10 - 12 to 10 - 10 mol for tetracycline hydrochloride and rolitetracycline respectively and up to 10 - 9 mol for its derivates. The investigations for cross reactions showed a high specificity for tetracycline (100%) and its intravenously appliable pyrrolidino-methyl derivative rolitetracycline (88%). Standard curves could be drawn up using either of the two compounds tetracycline and rolitetracycline as standard. The pharmaco-kinetic behaviour of the parenteral administrable tetracycline was analyzed as example for the possible applications of the tetracycline radioimmunoassay. Parallel animal tests administring 3 H tetracycline hydrochloride were performed for radioimmunoassay reference. The possible application of tetracycline radioimmunoassay in food analysis is discussed. (orig./MG) [de

  3. Sensitive chain specific radioimmunoassay for human immunoglobulins using monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, K; Alderson, T St.J.; Ellis, J [Ludwig Institute for Cancer Research, Cambridge (UK)

    1983-02-25

    A sensitive radioimmunoassay is described for human immunoglobulins. This solid-phase assay uses commercially available monoclonal antibodies and is specific for different Ig chain types. Levels of less than 20 ng/ml Ig are detectable. The assay is suitable for the analysis of human hybridoma supernatants.

  4. Development of radioimmunoassay for pantothenic acid in biological tissues

    International Nuclear Information System (INIS)

    Wyse, B.W.

    1977-01-01

    The purpose of this research was to develop a radioimmunoassay for quantitating pantothenic acid levels in biological tissues and to compare the new method with a microbiological procedure. Since pantothenic acid is a nonantigenic compound with a small molecular weight, it was treated as a hapten and conjugated with an immunogenic protein. A new technique for covalently linking haptens with primary alcohol groups to proteins was developed. To prepare an antiserum for the radioimmunoassay, pantothenic acid-bovine serum albumin antigen was injected into the foot pads of rabbits. As antibodies to pantothenic acid hapten were elicited they were characterized using three classical techniques: ring precipitant test, gel diffusion (Ouchterlony), and skin test (Arthus). For the radioimmunoassay an appropriate dilution of antiserum was incubated in the presence of tritium labeled pantothenic acid and non-radioactive pantothenic acid for the standard curve or tissue extracts containing pantothenic acid. After incubation overnight, the antibodies were precipitated and solubilized and the radioactivity was counted in a liquid scintillation counter. Blood pantothenic acid levels of sixty-eight senior citizens were determined by the radioimmunoassay and by microbiological assay with Lactobacillus plantarum. A highly significant correlation was found between the two assays

  5. A radioimmunoassay for anti-virus antibodies in farm animals

    International Nuclear Information System (INIS)

    Rodak, L.; Smid, B.; Sedlacek, M.

    1978-01-01

    A radioimmunoassay for determination of antibodies to Aujeszky's disease virus in piq serum is described. The results show a number of advantaqes of this method over the routinely employed virus-neutralization test. The possibility of using the RIA method in diagnosing other viral diseases of farm animals is suggested. (authors)

  6. Radioimmunoassay of follicle stimulating hornone in human plasma

    International Nuclear Information System (INIS)

    Akande, E.O.

    1976-01-01

    A radioimmunoassay method for Follicle Stimulating Hormone (fsh) in human plasma is described. The method proved to be reliable in determining fsh levels in normally menstruating women as well as women in varying clinical states. The patterns and levels of fsh obtained from 16 menstrual cycles in 12 normally menstruating women showed agreement with previous results of Franchimont, Faiman and Ryan, etc

  7. Solid phase radioimmunoassay for HBe Ag and anti-HBe

    Energy Technology Data Exchange (ETDEWEB)

    Froesner, G G; Deinhardt, F [Muenchen Univ. (Germany, F.R.). Inst. fuer Hygiene und Medizinische Mikrobiologie; Sugg, U [Tuebingen Univ. (Germany, F.R.). Abt. fuer Transfusionswesen mit Blutbank; Haas, H [Staedtische Krankenanstalten Esslingen (Germany, F.R.). Zentrallabor; Overby, R L [Abbott Labs., North Chicago, IL (USA)

    1978-04-01

    A highly sensitive solid phase radioimmunoassay for the detection of hepatitis Be-antigen (HBeAg) and anti-HBe is described. Iodine-125 labelled anti-HBe is used as a tracer. The assay is about 500 foLd more sensitive than immunodiffusion.

  8. Radioimmunoassay of calcitonin in plasma and cerebro-spinal fluid

    International Nuclear Information System (INIS)

    Cecchettin, M.; Comberti, E.; Quinzanini, M.; Albertini, A.; Tarquini, B.

    1985-01-01

    Some problems are discussed which, in analyzing the result of radioimmunoassay of calcitonin (CT), have to be taken into account regarding the standards used, the radioiodination, the antisere, if the assay was performed with or without extraction, the methode of extraction and the quality control. (H.W.). 11 refs.; 5 figs.; 4 tabs

  9. 21 CFR 864.7695 - Platelet factor 4 radioimmunoassay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Platelet factor 4 radioimmunoassay. 864.7695 Section 864.7695 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7695 Platelet...

  10. Direct salivary cortisol radio-immunoassay determination. Clinical applications

    International Nuclear Information System (INIS)

    Simon, C.; Cherfan, J.; Kurtz, F.; Vignon, F.; Schlienger, J.L.; Chabrier, G.

    1987-01-01

    Salivary cortisol levels reflect the biologically active free fraction of blood cortisol. The authors describe the results obtained with the aim of a radio-immunoassay commercial serum cortisol kit, without prealable extraction in different physiological and pathological situations. Salivary cortisol determination appears performant both in nycthemeral studies and in stimulation or freination tests [fr

  11. A solid-phase-radioimmunoassay for total serum thyroxine

    International Nuclear Information System (INIS)

    Moedder, G.; Sokolowski, G.

    1978-01-01

    A new solid phase radioimmunoassay for total serum thyroxine was evaluated over a longer time under clinical routine conditions and compared with an established test system. The results show up that the T 4 values are precise, reliable and reproducible, the is incomplicate to handle and well suitable for semiautomatic pipetting systems. (orig.) 891 MG [de

  12. Impact damage in aircraft composite sandwich panels

    Science.gov (United States)

    Mordasky, Matthew D.

    An experimental study was conducted to develop an improved understanding of the damage caused by runway debris and environmental threats on aircraft structures. The velocities of impacts for stationary aircraft and aircraft under landing and takeoff speeds was investigated. The impact damage by concrete, asphalt, aluminum, hail and rubber sphere projectiles was explored in detail. Additionally, a kinetic energy and momentum experimental study was performed to look at the nature of the impacts in more detail. A method for recording the contact force history of the impact by an instrumented projectile was developed and tested. The sandwich composite investigated was an IM7-8552 unidirectional prepreg adhered to a NOMEXRTM core with an FM300K film adhesive. Impact experiments were conducted with a gas gun built in-house specifically for delivering projectiles to a sandwich composite target in this specic velocity regime (10--140 m/s). The effect on the impact damage by the projectile was investigated by ultrasonic C-scan, high speed camera and scanning electron and optical microscopy. Ultrasonic C-scans revealed the full extent of damage caused by each projectile, while the high speed camera enabled precise projectile velocity measurements that were used for striking velocity, kinetic energy and momentum analyses. Scanning electron and optical images revealed specific features of the panel failure and manufacturing artifacts within the lamina and honeycomb core. The damage of the panels by different projectiles was found to have a similar damage area for equivalent energy levels, except for rubber which had a damage area that increased greatly with striking velocity. Further investigation was taken by kinetic energy and momentum based comparisons of 19 mm diameter stainless steel sphere projectiles in order to examine the dominating damage mechanisms. The sandwich targets were struck by acrylic, aluminum, alumina, stainless steel and tungsten carbide spheres of the

  13. Hyperglucagonaemia analysed by glucagon sandwich ELISA

    DEFF Research Database (Denmark)

    Albrechtsen, Nicolai Jacob Wewer; Hartmann, Bolette; Veedfald, Simon

    2014-01-01

    the extent to which the hyperglucagonaemia measured in clinical samples was caused by authentic glucagon. METHODS: We examined the performance of three commercial glucagon 'sandwich' ELISAs. The ELISA with the best overall performance was selected to compare glucagon measurements in clinical samples...... sensitivity for glucagon in plasma (>10-20 pmol/l). Thus, only the third assay was suitable for measuring glucagon concentrations in clinical samples. The ELISA and RIA measured similar glucagon levels in healthy individuals. Measurements of samples from individuals with abnormally high (type 2 diabetes...... or obese) or very elevated (post vagotomy with pyloroplasty, post-RYGB) glucagon levels were also similar in both assays. However, glucagon levels in participants with ESRD were much lower when measured by ELISA than by RIA, indicating that the apparent hyperglucagonaemia is not caused by fully processed...

  14. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  15. Fracture Analysis of Debonded Sandwich Columns Under Axial Compression

    DEFF Research Database (Denmark)

    May, A.; Avilés, F.; Berggreen, Christian

    A sandwich structure consists of two strong and stiff face sheets bonded to a weak low density core. The large separation between the face sheets provides increased bending rigidity and strength at low weight cost. Thus, sandwich structures frequently present better mechanical properties than...... monolithic structures of the same weight. The vast range of applications of such materials includes wind turbines, marine, and aerospace industries. In this work, geometrically nonlinear finite element analysis is conducted to investigate the fracture parameters and debond propagation of sandwich columns...

  16. A Debonded Sandwich Specimen Under Mixed Mode Bending (MMB)

    DEFF Research Database (Denmark)

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, Leif A.

    2008-01-01

    Face/core interface crack propagation in sandwich specimens is analyzed. A thorough analysis of the typical failure modes in sandwich composites was performed in order to design the MMB specimen to promote face/core debond fracture. Displacement, compliance and energy release rate expressions...... for the MMB specimen were derived from a superposition analysis. An experimental verification of the methodology proposed was performed using MMB sandwich specimens with H100 PVC foam core and E-glass/polyester non-crimp quadro-axial [0/45/90/-45]s DBLT-850 faces. Different mixed mode loadings were applied...

  17. Radioimmunoassay - renin - angiotensin. Principles of radioimmunoassay and their application in measuring renin and angiotensin

    Energy Technology Data Exchange (ETDEWEB)

    Krause, D K; Hummerich, W; Poulsen, K [eds.

    1978-01-01

    Typical pitfalls such as impurity of 'standard', tracer damage, crossreactivity of antiserum, unspecific binding of protecting proteins, blank effects with negative results, charcoal stripping, invisible coprecipitate or uncertainty in the analysis of the calibration curve (graph, logit-log, polynormal or spline function) can occur in any type of radioimmunoassay; they are detailed in the general part of this book. The special position occupied by radioimmunological quantification of parameters of the renin-angiotensin system creates additional, even more serious problems. While the radioimmunological determination of the decapeptide angiotensin I no longer causes major obstacles, measurement of the biologically active octapeptide angiotensin II is still only possible in a few centers. The (indirect) determination of plasma renin is characterized by a situation where the enzyme renin may be clearly defined in theory as a specific 10-11-leucine-leucine-endopeptidase cleaving only a decapeptide, but the actual renin assay, however, measures various forms of renin and other angiotensin-forming (or angiotensin-destroying) enzymes at the same time.

  18. The clinical evaluation of combining radionuclide imaging with radioimmunoassay for hashimoto's thyroiditis

    International Nuclear Information System (INIS)

    Huang Chenggang; Chen Xiaoyan; Deng Yan

    2003-01-01

    By analysing nuclide image characteristics and radioimmunoassay data of 61 cases with Hashimoto's thyroiditis (HT), HT can be classified five types as below: uneven distribution, diffusion, with hyperfunction, with nodules, nearly normal. The results of radionuclide imaging and the radioimmunoassay of all the types indicate that HT can be preliminarily diagnosed by conscientiously analysing nuclide image characteristics and radioimmunoassay data and linking clinical symptoms and signs

  19. Mechanical and vibro-acoustic aspects of composite sandwich cylinders

    NARCIS (Netherlands)

    Yuan, C.

    2013-01-01

    Designing a fuselage involves many considerations such as strength and stability, fatigue, damage tolerance, fire and lightning resistance, thermal and acoustic insulation, production, inspection, maintenance and repair. In the background of the application of composite sandwich structures on the

  20. Smart FRP Composite Sandwich Bridge Decks in Cold Regions

    Science.gov (United States)

    2011-07-01

    In this study, new and integrated Smart honeycomb Fiber-Reinforced Polymer (S-FRP) : sandwich materials for various transportation construction applications, with particular emphasis : on highway bridge decks in cold regions, were developed and teste...

  1. A radioimmunoassay for the detection of adrenal autoantibodies

    International Nuclear Information System (INIS)

    Kosowicz, J.; Gryczynska, M.; Bottazzo, G.F.

    1986-01-01

    A solid phase radioimmunoassay for adrenal antibodies is described. In the assay plastic tubes coated with adrenal microsomes (100 μg/ml) were incubated with human sera diluted from 1:50 to 1:5000 and the retained antibodies detected by subsequent incubation with 125 I-labelled protein A. The method was precise over the range of serum dilution of 1:250 to 1:5000. In the group of 30 patients with Addison's disease 19 had positive results in adrenal antibody radioimmunoassay (RIA). Comparative studies of RIA and immunofluorescence (IFL) revealed that there was partial correlation of adrenal antibody results in patients with high titre antibodies whereas RIA usually was more sensitive than IFL in patients with low titre antibodies. Computerized tomography (CT) displayed bilateral adrenal atrophy in most patients who had adrenal antibodies. On the other hand, patients with low RIA results and negative IFL antibodies had predominantly adrenal calcifications on scans. (author)

  2. Measurements of urinary kinins by HPLC-radioimmunoassay

    International Nuclear Information System (INIS)

    Fejes-Toth, G.; Naray-Fejes-Toth, A.; Froelich, J.C.

    1984-01-01

    In this paper the authors describe a method for the individual determination of urinary kinins. Extraction from the urine is performed on an Amberlite CG-50 column and kinins are eluted with formic acid. The samples are further purified and kinins are separated by reversed phase HPLC. Bradykinin and lysylbradykinin are quantified by a sensitive radioimmunoassay capable of detecting 0.1 fmol of either peptide. Procedural losses are monitored by measuring the recovery of [ 3 H]bradykinin and [ 3 H]lysylbradykinin. Simple methods for labeling of bradykinin and lysylbradykinin with tritium are also presented. Recoveries of [ 3 H]bradykinin and [ 3 H]lysylbradykinin from biological material ranged between 77 and 91%. The combination of HPLC with radioimmunoassay makes it possible to determine kinin concentrations of biological samples with a higher sensitivity and greater specificity than previous methods. (Auth.)

  3. Development of a homologous iodine-125 labelled progesterone radioimmunoassay system

    International Nuclear Information System (INIS)

    Elbanna, I.M.; El-Asrag, H.A.; Gado, M.S.; Gamal, M.H.

    1985-01-01

    Detailed procedure description of an iodinated progesterone radioimmunoassay system development is reported. Immunization regime with progesterone 11 α-hemisuccinate: BSA gave 1:6000 antibody titre within a period of 6 months. Minimal amount of the immunogen was spent to obtain a stock of the antiserum. Conjugation of progesterone 11 α-hemisuccinate to tyrosine methyl ester using the isobutyl-chloroformate reaction gave a product with less patch to patch variations in tracer characteristics. At home radioiodination with 125 I reduced the expenses drastically and resulted in extended tracer shelf life (up to 3 months). The use of the second antibody method of separating bound from free hormone proved to be more convenient and brought the progesterone radioimmunoassay system to routine work

  4. Development of failure-detecting device for γ radioimmunoassay counter

    International Nuclear Information System (INIS)

    Shao Xianzhi; Zhang Bingfeng

    1997-01-01

    A failures-detecting device based on single chip microcomputer technique for detecting of failures of γ radioimmunoassay counter is developed. The device can output signals of variable amplitude and frequency similar to the pulse of γ particle for shooting problem parts of γ counter's detecting system. By automatically comparing the shapes and amplitudes of the two signals to and from an amplifier unit, the device can distinguish if the amplifier unit works normally. The differential-input amplifier circuit gives 0.1% accuracy for the measurement of the stability of high voltage. The pulse widen circuit of this device allows for middle speed A/D detecting of periodical low-frequency pulse waves of micro-second width. This device is used specifically for the maintaining and failure-detecting of γ radioimmunoassay counter

  5. /sup 125/I Radioimmunoassay of serum ursodeoxycholyl conjugates

    Energy Technology Data Exchange (ETDEWEB)

    Hill, A.; Ross, P.E.; Bouchier, I.A.D. (Ninewells Hospital and Medical School, Dundee (UK))

    1983-02-07

    A radioimmunoassay for serum ursodeoxycholic conjugates using an iodine-125 ligand has been developed. The bile acid was present in normal fasting serum (0.19 +- SD 0.19 ..mu..mol/l, n=24) and 2-hour post-prandial serum (0.8 +- SD 0.8 ..mu..mol/l, n=16). Gallstone patients undergoing oral ursodeoxycholic acid therapy had significantly higher post-prandial serum levels (21.5 +- SD 14.0 ..mu..mol/l, n=15) by radioimmunoassay. Gas liquid chromatography analysis indicated that in normal serum ursodeoxycholic acid was totally conjugated, whereas sera from gallstone patients contained a proportion as the free bile acid (10.2 +- SD 8.1 ..mu..mol/l, n=15). Following an oral dose of ursodeoxycholic acid, both unconjugated and conjugated forms of the bile acid appeared in the serum of healthy individuals.

  6. Radioimmunoassay for yeast killer toxin from Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Siddiqui, F.A.; Bussey, H.

    1981-01-01

    A radioimmunoassay was developed for the K1 killer toxin from strain T158C/S14a of Saccharomyces cerevisiae. Iodine 125-labelled toxin was made to a specific activity of 100 μCi/mg of protein. Antibody to purified toxin was prepared in rabbits using toxin cross-linked to itself. These antibodies, partially purified by 50 percent ammonium sulfate precipitation and Sepharose CL-6B column chromatography, produced one precipitation band with killer toxin and bound 125 I-labelled toxin in a radioimmunoassay. The antibody preparation also bound with the toxins from another K1 killer, A364A, and three chromosomal superkiller mutants derived from it. (auth)

  7. Radioimmunoassay for parathyrin characterization of six different antigens and antisera

    International Nuclear Information System (INIS)

    Voll, R.; Schmidt-Gayk, H.; Wiedemann, J.; Hehrmann, R.

    1978-01-01

    We studied six different antisera to bovine or porcine parathyrin (parathyroid hormone, PTH), produced in rabbit, guinea pigs, sheep or goat, two of which are commercially available. These antisera were characterized with regard to species specificity, affinity and their ability to identify patients with primary hyperparathroidism. In this heterologous radioimmunoassay system in which[ 125 I]parathyrin is used as a tracer, some cross-reactivity of the antisera to the hormone or hormone fragments present in human serum was demonstrated. However, there is some overlap of serum immunoreactive parathyrin in patients with or without primary hyperparathyroidism. The results of this and other studies illustrate the necessity fo a homolgous radioimmunoassay for human parathyrin. (orig.) [de

  8. Detection of gonococcal antigens in urine by radioimmunoassay

    International Nuclear Information System (INIS)

    Thornley, M.J.; Wilson, D.V.; Hormaeche, R.D. de; Coombs, R.R.A.; Oates, J.K.

    1979-01-01

    A method of detecting gonococcal antigens by solid-phase radioimmunoassay with radioactively labelled antibody is described. A specificity test has been developed that enables this method to be used to detect gonococcal antigens in urine sediments. When sediments from samples of urine from male patients with gonorrhoea were tested, 31 (74%) of 42 gave positive results, clearly distinguishing them from sediments from urine samples from men with non-specific urethritis, none of which was positive. Ten of 14 urine sediments from urine samples from women with gonorrhoea gave positive results, as did 3 of 18 sediments from urine samples from women patients without gonorrhoea.These experiments demonstrate that gonococcal antigens can be detected in urine by radioimmunoassay; the method could be useful in diagnosis if, after refinement, its sensitivity and specificity were to be increased. (author)

  9. Measurement of endotoxin. I. Fundamental studies on radioimmunoassay of endotoxin

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, H [Okayama Univ. (Japan). School of Medicine

    1976-08-01

    A method for estimating endotoxin by radioimmunoassay was recently introduced. The present paper describes improvements in the speed and sensitivity on this endotoxin measurement. Antigen was purified from E. coli 0111: B4(B) lipopolysaccharide by centrifugation and dialysis. Purified anti-endotoxin antibody was prepared from immunized rabbit serum. A radioimmunoassay system was established with the antigen and antibody. Dextran-coated charcoal was used to separate the antibody-bound antigen from free antigen. Experimental studies were also performed on possible factors related to the antigen-antibody reaction. Accurate measurements on quantitites as low as 100 pg/ml (10 ng/ml in the plasma) were performed by the dextran-coated charcoal method, and the reaction time was reduced to 2 hr at 4/sup 0/C. This new method does not require strict sterilization or aseptic handling, and therefore is quite practical for quantitative measurements of endotoxin.

  10. 125I radioimmunoassay for primary conjugated bile salts

    International Nuclear Information System (INIS)

    Spenney, J.G.; Johnson, B.J.; Hirschowitz, B.I.; Mihas, A.A.; Gibson, R.

    1977-01-01

    Cholylglycylhistamine, a derivative of cholic acid, has been synthesized and characterized. This derivative has been iodinated using Na125I and chloramine-T and purified free from unlabeled cholylglycylhistamine. Application of this iodinated bile salt derivative to radioimmunoassay of bile salts in human serum is reported. Antibody titers have uniformly increased over titers used in tritium-based assays; some antibodies are usable in dilutions of 1 : 80,000. The radioimmunoassay described here was found to measure predominantly the primary conjugated bile salts. Sensitivity has been maintained, with the least detectable amount being 0.5 pmoles per assay tube. Normal values in human serum are 3.47 +- 2.16 (SD) nmoles per ml

  11. Double antibody solid-phase radioimmunoassay for staphylococcal enterotoxin A

    International Nuclear Information System (INIS)

    Lindroth, S.; Niskanen, A.

    1977-01-01

    A double antibody solid-phase (DASP) radioimmunoassay for staphylococcal enterotoxin A is described. In the assay the antigen-antibody complex is precipitated by anti-rabbit serum which is adsorbed onto a solid carrier (cellulose). The method is sensitive to 200 pg of enterotoxin. It was possible to detect a little as 2-5 ng of enterotoxin A/ml food extract from minced meat and sausage. Enterotoxins B and C were not found to inhibit the uptake of labled enterotoxin A at a level which might distort the results of the enterotoxin A assay. The DASP technique is sensitive, rapid, and easy to perform and thus compares favorably with other radioimmunoassays for enterotoxin. (orig.) [de

  12. Development of a radioimmunoassay for pig pancreatic kallikrein

    Energy Technology Data Exchange (ETDEWEB)

    Fink, E; Guettel, C [Muenchen Univ. (Germany, F.R.). Chirurgische Klinik

    1978-07-01

    A radioimmunoassay for the determination of pig pancreatic kallikrein was developed. The chloramine-T method was employed for the labelling of the antigen with /sup 125/I. The assay allows the determination of kallikrein in concentrations as low as 0.4 ..mu..g/l. Pig urinary and pig submandibular kallikreins are indistinguishable from pig pancreatic kallikrein by the assay. No cross reactivity was observed for bovine trypsin and chymotrypsin, porcine trypsin and kallikreins of guinea pig submandibular glands and guinea pig coagulation glands. Because of the high specificity of the assay, which is not attainable with conventional assays based on the enzymatic activity, the radioimmunoassay is highly suited for investigations into the physiological role and the pharmacological mechanism of action of pig glandular kallikreins.

  13. Solid phase 125I labelled radioimmunoassay for spermidine

    International Nuclear Information System (INIS)

    Zhao Shimin

    1991-01-01

    Using 125 I labelled monoclonal antibody against spermidine and solid phase antigen spermidine-bovine serum albumin conjugate, the radioimmunoassay for spermidine was developed. The sensitivity of this method was about 8 times higher than that of liquid phase 14 C labelled spermidine radioimmunoassay, reaching detection limit of 10 ng/ml (0.5 ng/tube). The working range of standard curve was 0-10 5 ng/ml. The new method was suitable for spermidine measurements in saliva, stomach fluid, and cerebrospinal fluid. The coefficients of variation (CV) of within and between-assay were 4% and 13%, respectively. Preliminary clinical measurements showed that the spermidine levels in saliva of cancer patients and in cerebrospinal fluid of leukemia patients were significantly elevated

  14. Studies on the production of insulin radio-immunoassay kit

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J R; Kim, T H; Kim, Y S [Korea Atomic Energy Research Inst., Seoul (Republic of Korea)

    1978-01-01

    Insulin was labelled with Iodine-125 in about 35% yield by applying the chloramine-T method. The specific activity of the labelled product was about 100 ..mu..Ci/ug. To use the labelled product for the radioimmunoassay of insulin, the well labelled fractions were selected through a starch gel electrophoresis autoradiography, elution, and subsequent incubations with insulin antibodies. The results of the standardizations using the well labelled insulin fractions for radioimmunoassay indicated that the ratio of the antibody bound (B) to the free (F) insulin-/sup 125/I is 0.2 to 1.6 in the standard insulin dose of up to 50 ..mu..U/ml, the relatively steep dose gradient. Kits were prepared and the stabilities were also checked.

  15. Tailoring Sandwich Face/Core Interfaces for Improved Damage Tolerance

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Berggreen, Christian; Carlsson, Leif A.

    2010-01-01

    A face/core debond in a sandwich structure may propagate in the interface or kink into either the face or core. It is found that certain modifications of the face/core interface region influence the kinking behavior, which is studied experimentally in the present paper. A sandwich double cantilever....... The transition points where the crack kinks are identified and the influence of four various interface design modifications on the propagation path and fracture resistance are investigated....

  16. General approach to standardization of the solid-phase radioimmunoassay for quantitation of class-specific antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Zollinger, W D; Boslego, J W [Walter Reed Army Inst. of Research, Washington, DC (USA)

    1981-10-30

    The feasibility of using an anti-human immunoglobulin/human immunoglobulin/(/sup 125/I)anti-human immunoglobulin 'sandwich' in a solid-phase radioimmunoassay to produce a standard curve which could be used to quantitate antigen-specific antibody of a particular immunoglobulin class was investigated. The amount of secondary antibody (SAb) bound was determined as a function of whether the primary antibody (PAb) was bound to its specific solid-phase antigen or by a solid-phase anti-human immunoglobulin. No significant difference between the two values was observed. Quantitation of anti-tetanus toxoid antibody by this method was in a good agreement with quantitative precipitin tests. Comparison of SAb binding as a function of the way the PAb is bound was extended to class-specific PAb by use of murine monoclonal antibodies to meningococcal antigens. In most cases somewhat greater binding of SAb occurred when PAb was bound to antigen, but in several cases where low avidity antibody and/or poor quality antigens were used, greater SAb binding occurred when PAb was bound by anti-mouse immunoglobulin. The results indicate that this approach may be useful as a general method for standardizing the SPRIA and other solid-phase immunoassays such as the ELISA to measure class-specific antibody.

  17. Semiautomated radioimmunoassay for mass screening of drugs of abuse

    International Nuclear Information System (INIS)

    Sulkowski, T.S.; Lathrop, G.D.; Merritt, J.H.; Landez, J.H.; Noe, E.R.

    1975-01-01

    A rapid, semiautomated radioimmunoassay system for detection of morphine, barbiturates, and amphetamines is described. The assays are applicable to large drug abuse screening programs. The heart of the system is the automatic pipetting station which can accomplish 600 pipetting operations per hour. The method uses 15 to 30 μl for the amphetamine and combined morphine/barbiturate assays. A number of other drugs were tested for interference with the assays and the results are discussed

  18. Combined high-performance liquid chromatography-radioimmunoassay for cytokinins

    International Nuclear Information System (INIS)

    MacDonald, E.M.S.; Akiyoshi, D.E.; Morris, R.O.

    1981-01-01

    The cytokinins isopentenyladenosine and ribosylzeatin were conjugated to bovine serum albumin and the conjugates used to raise antisera in rabbits. The resulting antisera had high specificity towards the cytokinin haptens and low cross-reactivity towards other purines. They were used as the basis for a radioimmunoassay for cytokinins, which, when applied in conjunction with high-performance liquid chromatography, allowed rapid and sensitive (to the picogram range) estimation and identification of multiple cytokinins from natural plant and bacterial sources. (orig.)

  19. Determination of digoxin by enzyme immunoassay and radioimmunoassay

    International Nuclear Information System (INIS)

    Mueller, H.; Braeuer, H.; Foerster, G.; Reinhardt, M.

    1978-01-01

    The results of parallel determinations of digoxin in the sera of non selected patients (n=104) by enzyme immunoassay (EMIT.EIA) and radioimmunoassay (J-125 labeled RIA) were compared with each other. The determinations revealed considerably different concentrations; the values determined by EIA were statistical lower (for EIA 1,09+'0,99ng/ml, for RIA 1,34+'1,01ng/ml, p [de

  20. Detection of carcinogen-DNA adducts by radioimmunoassay

    International Nuclear Information System (INIS)

    Poirier, M.C.; Yuspa, S.H.; Weinstein, I.B.; Blobstein, S.

    1977-01-01

    Covalent binding of carcinogen to nucleic acids is believed to be an essential component of the carcinogenic process, so it is desirable to have highly sensitive and specific methods for detecting such adducts in cells and tissues exposed to known and suspected carcinogens. A radioimmunoassay is here described capable of detecting nanogram amounts of DNA adducts resulting from the covalent binding of the carcinogen N-2-acetylaminofluorene and its activated N-acetoxy derivative. (author)

  1. Optimization of composite sandwich cover panels subjected to compressive loadings

    Science.gov (United States)

    Cruz, Juan R.

    1991-01-01

    An analysis and design method is presented for the design of composite sandwich cover panels that include the transverse shear effects and damage tolerance considerations. This method is incorporated into a sandwich optimization computer program entitled SANDOP. As a demonstration of its capabilities, SANDOP is used in the present study to design optimized composite sandwich cover panels for for transport aircraft wing applications. The results of this design study indicate that optimized composite sandwich cover panels have approximately the same structural efficiency as stiffened composite cover panels designed to satisfy individual constraints. The results also indicate that inplane stiffness requirements have a large effect on the weight of these composite sandwich cover panels at higher load levels. Increasing the maximum allowable strain and the upper percentage limit of the 0 degree and +/- 45 degree plies can yield significant weight savings. The results show that the structural efficiency of these optimized composite sandwich cover panels is relatively insensitive to changes in core density. Thus, core density should be chosen by criteria other than minimum weight (e.g., damage tolerance, ease of manufacture, etc.).

  2. Dynamic Response of Functionally Graded Carbon Nanotube Reinforced Sandwich Plate

    Science.gov (United States)

    Mehar, Kulmani; Panda, Subrata Kumar

    2018-03-01

    In this article, the dynamic response of the carbon nanotube-reinforced functionally graded sandwich composite plate has been studied numerically with the help of finite element method. The face sheets of the sandwich composite plate are made of carbon nanotube- reinforced composite for two different grading patterns whereas the core phase is taken as isotropic material. The final properties of the structure are calculated using the rule of mixture. The geometrical model of the sandwich plate is developed and discretized suitably with the help of available shell element in ANSYS library. Subsequently, the corresponding numerical dynamic responses computed via batch input technique (parametric design language code in ANSYS) of ANSYS including Newmark’s integration scheme. The stability of the sandwich structural numerical model is established through the proper convergence study. Further, the reliability of the sandwich model is checked by comparison study between present and available results from references. As a final point, some numerical problems have been solved to examine the effect of different design constraints (carbon nanotube distribution pattern, core to face thickness ratio, volume fractions of the nanotube, length to thickness ratio, aspect ratio and constraints at edges) on the time-responses of sandwich plate.

  3. Effect of nanomodified polyester resin on hybrid sandwich laminates

    International Nuclear Information System (INIS)

    Anbusagar, NRR.; Giridharan, P.K.; Palanikumar, K.

    2014-01-01

    Highlights: • Effect of nanomodified polyester resin on hybrid sandwich laminates is evaluated. • The hybrid sandwich laminates are fabricated with varying wt% of nanoclay. • Flexural, impact and moisture absorbtion properties are evaluated for hybrid composites. • Scanning electron microscopy is utilized to analyze the dispersion of clay and fractured surfaces of the nanocomposites. - Abstract: Effect of nanoclay modified polyester resin on flexural, impact, hardness and water absorption properties of untreated woven jute and glass fabric hybrid sandwich laminates have been investigated experimentally. The hybrid sandwich laminates are prepared by hand lay-up manufacturing technique (HL) for investigation. All hybrid sandwich laminates are fabricated with a total of 10 layers, by varying the extreme layers and wt% of nanoclay in polyester resin so as to obtain four different combinations of hybrid sandwich laminates. For comparison of the composite with hybrid composite, jute fiber reinforced composite laminate also fabricated. X-ray diffraction (XRD) results obtained from samples with nanoclay indicated that intergallery spacing of the layered clay increases with matrix. Scanning electron microscopy (SEM) gave a morphological picture of the cross-sections and energy dispersive X-ray spectroscopy (EDS) allowed investigating the elemental composition of matrix in composites. The testing results indicated that the flexural properties are greatly increased at 4% of nanoclay loading while impact, hardness and water absorption properties are increased at 6% of nanoclay loading. A plausible explanation for high increase of properties has also been discussed

  4. A newly developed precise and sensitive radioimmunoassay for clonidine

    International Nuclear Information System (INIS)

    Arndts, D.; Struck, C.J.; Staehle, H.

    1979-01-01

    A new precise and sensitive radioimmunoassay for clonidine has been developed. Synthesis and analysis of the hapten (4-carboxy-clonidine; St 1984) as well as antibody production in rabbits are described in detail. At a final dilution of 1:1000 the resulting immune serum binds 50% of a tritiated clonidine standard containing 1 ng of clonidine. The detection limit of the presented radioimmunoassay for clonidine is 0.1 ng/ml. The coefficient of variation did not exceed 4.3% for any of 7 standard determinations with 5 replicates. There was no relevant crossreactivity of inactive clonidine metabolites apart from 4-OH-clonidine. To avoid any errors from cross-reaction clonidine was selectively and quantitatively extracted into diethylether from unknown plasma samples. Following concentration of the extracts even such low concentrations as 20 pg of clonidine/ml plasma were detectable. With the radioimmunoassay applied in pharmacokinetic studies a maximal clonidine concentration in blood plams of healthy human volunteers was determined to 0.6 ng/ml 1.5 h after oral administration of 150 μg. (orig.) [de

  5. Radioimmunoassay of thyrotropin releasing hormone in plasma and urine

    International Nuclear Information System (INIS)

    Saito, Shiro; Musa, Kimitaka; Yamamoto, Suzuyo; Oshima, Ichiyo; Funato, Toyohiko

    1975-01-01

    A sensitive and specific radioimmunoassay has been developed capable of measuring thyrotropin releasing hormone (TRH) in extracted human plasma and urine. All of three TRH analogues tested had little cross-reactivity to antibody. Luteinizing hormone releasing hormone, lysine vasopressin, rat growth hormone and bovine albumin were without effect, but rat hypothalamic extract produced a displacement curve which was parallel to that obtained with the synthetic TRH. Sensitivity of the radioimmunoassay was 4 pg per tube with intraassay coefficient of variation of 6.2-9.7%. Synthetic TRH could be quantitatively extracted by methanol when added to human plasma in concentration of 25, 50 and 100 pg/ml. TRH immunoreactivity was rapidly reduced in plasma at 20 0 C than at 0 0 C, but addition of peptidase inhibitors, FOY-007 and BAL, prevented the inactivation of TRH for 3 hr at 0 0 C. The TRH in urine was more stable at 0 0 C than 20 0 C, and recovered 75+-4.6% at 24 hr after being added. The plasma levels of TRH were 19 pg/ml or less in normal adults and no sex difference was observed. The rate of disappearance of TRH administered i.v. from the blood could be represented as half-times of 4-12 min. Between 5.3-12.3% of the injected dose was excreted into urine within 1 hr as an immunoreactive TRH. These results indicate the usefulness of TRH radioimmunoassay for clinical investigation. (auth.)

  6. Radioimmunoassay of creatine kinase isoenzymes in human serum: isoenzyme MM

    International Nuclear Information System (INIS)

    Van Steirteghem, A.C.; Zweig, M.H.; Schechter, A.N.

    1978-01-01

    Measurement of the mass concentration of serum enzymes by radioimmunoassay provides direct quantitation of specific isoenzymes and may be less subject to some of the limitations of traditional assay procedures for enzymes. We describe the development of a sensitive and specific radioimmunoassay for the muscle isoenzyme of creatine kinase, CK-MM, in human serum. CK-MM, purified from human skeletal muscle, was used to raise high-titer antisera and for iodination by the Chloramine T method. The radioimmunoassay required 50 μl of sample, utilized a double-antibody separation method, and was completed in 24 h. Cross reactivity with CK-BB was virtually zero, 3 to 17 percent with CK-MB. The mass concentration of CK-MM in the serum of healthy subjects ranged from 36 to 1668 μg/liter and correlated closely with total CK enzymatic activity. Serum concentrations of CK-MM from casually selected patients correlated less well with total CK enzymatic activity, suggesting the existence of other CK isoenzymes or the presence of inactive forms

  7. Improved radioimmunoassay for creatine kinase isoenzymes in plasma

    International Nuclear Information System (INIS)

    Ritter, C.S.; Mumm, S.R.; Roberts, R.

    1981-01-01

    We describe convenient and relatively rapid procedures for purifying creatine kinase isoenzymes MM, BB, and MB, and their use in an improved radioimmunoassay for creatine kinase isoenzymes in plasma. The modifications include use of: (a) BB with a specific activity of 400 kU/G, which can be labeled with a specific radioactivity of 20 Ci/g; (b) albumin-free purified MB as inhibitor; (c) antiserum to MB creatine kinase; and (d) a second-antibody technique that necessitates only a 15-min incubation. The radioimmunoassay for MB has a sensitivity of 0.2 μg/L (80 mU/L) and a CV of <5%. Plasma MB average 22 (SD 12) μg/L in 200 normal subjects; 24 (SD 12) μg/L in 200 patients with chest pain without infarction; and 23 (SD 7) μg/L in 43 patients with renal disease, whether measured before or after dialysis. Peak values for plasma MB averaged 191 (SD 86) μg/L in 325 patients with documented myocardial infarction; BB was negligible. Extensive clinical experience indicates the radioimmunoassay to be suitably rapid, highly sensitive, and reliable as a diagnostic assay for MB on plasma

  8. High-accuracy energy formulas for the attractive two-site Bose-Hubbard model

    Science.gov (United States)

    Ermakov, Igor; Byrnes, Tim; Bogoliubov, Nikolay

    2018-02-01

    The attractive two-site Bose-Hubbard model is studied within the framework of the analytical solution obtained by the application of the quantum inverse scattering method. The structure of the ground and excited states is analyzed in terms of solutions of Bethe equations, and an approximate solution for the Bethe roots is given. This yields approximate formulas for the ground-state energy and for the first excited-state energy. The obtained formulas work with remarkable precision for a wide range of parameters of the model, and are confirmed numerically. An expansion of the Bethe state vectors into a Fock space is also provided for evaluation of expectation values, although this does not have accuracy similar to that of the energies.

  9. Adiabatically modeling quantum gates with two-site Heisenberg spins chain: Noise vs interferometry

    Science.gov (United States)

    Jipdi, M. N.; Tchoffo, M.; Fai, L. C.

    2018-02-01

    We study the Landau Zener (LZ) dynamics of a two-site Heisenberg spin chain assisted with noise and focus on the implementation of logic gates via the resulting quantum interference. We present the evidence of the quantum interference phenomenon in triplet spin states and confirm that, three-level systems mimic Landau-Zener-Stückelberg (LZS) interferometers with occupancies dependent on the effective phase. It emerges that, the critical parameters tailoring the system are obtained for constructive interferences where the two sets of the chain are found to be maximally entangled. Our findings demonstrate that the enhancement of the magnetic field strength suppresses noise effects; consequently, the noise severely impacts the occurrence of quantum interference for weak magnetic fields while for strong fields, quantum interference subsists and allows the modeling of universal sets of quantum gates.

  10. Study of Aerosol Optical Properties Over Two Sites in the Foothills of the Central Himalayas

    Science.gov (United States)

    Rupakheti, D.; Kang, S.; Cong, Z.; Rupakheti, M.; Tripathee, L.; Panday, A. K.; Holben, B.

    2018-04-01

    Atmospheric aerosol possesses impacts on climate system and ecological environments, human health and agricultural productivity. The environment over Himalayas and Tibetan Plateau region are continuously degraded due to the transport of pollution from the foothills of the Himalayas; mostly the Indo-Gangetic Plain (IGP). Thus, analysis of aerosol optical properties over two sites; Lumbini and Kathmandu (the southern slope of central Himalayas) using AERONET's CIMEL sun photometer were conducted in this study. Aerosol optical depth (AOD at 500 nm), angstrom exponent (α or AE), volume size distribution (VSD), single scattering albedo (SSA) and asymmetry parameter (AP) were studied for 2013-2014 and the average AOD was found to be: 0.64 ± 0.41 (Lumbini) and 0.45 ± 0.30 (Kathmandu). The average AE was found to be: 1.25 ± 0.24 and 1.26 ± 0.18 respectively for two sites. The relation between AOD and AE was used to discriminate the aerosol types over these sites which indicated anthropogenic, mixed and biomass burning origin aerosol constituted the major aerosol types in Lumbini and Kathmandu. A clear bi-modal distribution of aerosol volume size was observed with highest volume concentration during the post-monsoon season in fine mode and pre-monsoon season in coarse mode (Lumbini) and highest value over both modes during pre-monsoon season in Kathmandu. The single scattering albedo (SSA) and asymmetry parameter (AP) analyses suggested aerosols over the Himalayan foothills sites are dominated by absorbing and anthropogenic aerosols from urban and industrial activities and biomass burning. Long-term studies are essential to understand and characterize the nature of aerosol over this research gap zone.

  11. A two-site mean field model of discontinuous dynamic recrystallization

    International Nuclear Information System (INIS)

    Bernard, P.; Bag, S.; Huang, K.; Loge, R.E.

    2011-01-01

    Highlights: → Discontinuous dynamic recrystallization (DDRX) is modelled at the grain scale. → The two-site mean field approach allows introducing topological information. → DDRX kinetics, flow stress curves and recrystallized grain size are well predicted. → Temperature, strain rate and initial grain size effects are successfully described. → Grain size dependence naturally emerges from the model and agrees with experiment. - Abstract: The paper describes a new model of discontinuous dynamic recrystallization (DDRX) which can operate in constant or variable thermomechanical conditions. The model considers the elementary physical phenomena at the grain scale such as strain hardening, recovery, grain boundary migration, and nucleation. The microstructure is represented through a set of representative grains defined by their size and dislocation density. It is linked to a constitutive law giving access to the polycrystal flow stress. Interaction between representative grains and the surrounding material is idealized using a two-site approach whereby two homogeneous equivalent media with different dislocation densities are considered. Topological information is incorporated into the model by prescribing the relative weight of these two equivalent media as a function of their volume fractions. This procedure allows accounting for the well-known necklace structures. The model is applied to the prediction of DDRX in 304 L stainless steel, with parameters identified using an inverse methodology based on a genetic algorithm. Results show good agreement with experimental data at different temperatures and strain rates, predicting recrystallization kinetics, recrystallized grain size and stress-strain curve. Parameters identified with one initial grain size lead to accurate results for another initial grain size without introducing any additional parameter.

  12. Feasibility study of a SiC sandwich neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jian, E-mail: caepwujian@163.com [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province (China); Lei, Jiarong, E-mail: jiarong_lei@163.com [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province (China); Jiang, Yong; Chen, Yu; Rong, Ru; Zou, Dehui; Fan, Xiaoqiang [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province (China); Chen, Gang; Li, Li; Bai, Song [Nanjing Electronic Devices Institute, Nanjing 210016 (China)

    2013-04-21

    Semiconductor sandwich neutron spectrometers are suitable for in-pile measurements of fast reactor spectra thanks to their compact and relatively simple design. We have assembled and tested a sandwich neutron spectrometer based on 4H-silicon carbide (4H-SiC) Schottky diodes. The SiC diodes detect neutrons via neutron-induced charged particles (tritons and alpha particles) produced by {sup 6}Li(n,α){sup 3}H reaction. {sup 6}LiF neutron converter layers are deposited on the front surface of Schottky diodes by magnetron sputtering. The responses of SiC diodes to charged particles were investigated with an {sup 241}Am alpha source. A sandwich neutron spectrometer was assembled with two SiC Schottky diodes selected based on the charged-particle-response experimental results. The low-energy neutron response of the sandwich spectrometer was measured in the neutron field of the Chinese Fast Burst Reactor-II (CFBR-II). Spectra of alpha particles and tritons from {sup 6}Li(n,α){sup 3}H reaction were obtained with two well-resolved peaks. The energy resolution of the sum spectrum was 8.8%. The primary experimental results confirmed the 4H-SiC sandwich neutron spectrometer's feasibility. -- Highlights: ► Sandwich neutron spectrometer employing 4H-SiC as a detecting material has been developed for the first time. ► {sup 6}LiF neutron converter has been deposited on the surface of 4H-SiC Schottky diode. ► Preliminary testing results obtained with the 4H-SiC sandwich neutron spectrometer are presented.

  13. Liquid-phase and solid-phase radioimmunoassay with herpes simplex virus type 1 nucleocapsids

    International Nuclear Information System (INIS)

    Bystricka, M.; Rajcani, J.; Libikova, H.; Sabo, A.; Foeldes, O.; Sadlon, J.

    1985-01-01

    Liquid-phase radioimmunoassay and solid-phase radioimmunoassay are described using 125 I-labelled or immobilized nucleocapsids (NC) of herpes simplex virus (HSV) type1. These techniques appeared sensitive and specific for quantitation of HSV-NC antigens and corresponding antibodies. (author)

  14. Comparison of commercially available radioimmunoassays for the determination of bile acids in serum

    Energy Technology Data Exchange (ETDEWEB)

    Wildgrube, H.J.; Schiller, W.; Winkler, M.; Weber, J.; Campana, H.; Mauritz, G.

    1982-05-01

    Three commercially available radioimmunoassays for the determination of bile acids in serum were evaluated with respect to specificity and precision. The SLCG-radioimmunoassay (Abbott) measures only sulphated glycolithocholic acid, the CG-radioimmunoassay (Abbott) measures chiefly cholic acid conjugates, and the CBA-radioimmunoassay (Becton-Dickinson) measures all conjugated bile acids, with an over-response to taurine metabolites. With respect to cross reactions, the performances of the CG-and the CBA-radioimmunoassays differed significantly from those stated by the manufacturers, the former showing a 32% response to taurocholic acid, the latter responding only 118% to taurochenodeoxycholic acid. At physiological concentrations of albumin + globulin, the recovery of defined cholanic acids was 85-101%. Good reproducibility was shown by the CG-radioimmunoassay in the range 0.5-10.9 ..mu..mol/l, by the CBA-radioimmunoassay in the range 1.0-25.0 ..mu..mol/l, and by the SLCG-radioimmunoassay in the range 0.5-3.0 ..mu..mol/l. There were no important differences in the inter- and intra-assay precision of the three methods.

  15. Characterization of sandwich panels for indentation and impact

    International Nuclear Information System (INIS)

    Shazly, M; Salem, S; Bahei-El-Din, Y

    2013-01-01

    The integrity of sandwich structures which are susceptible to impact may deteriorate significantly due to collapse of the core material and delamination of the face sheets. The integration of a thin polyurethane interlayer between the composite face sheet and foam core is known to protect the core material and substantially improve the resistance to impact. The objective of the present work is to characterize the response of sandwich panels, as well as that of the constituents to impact. In particular, the response of polyurethane and foam samples under a range of quasi-static and dynamic loading rates is determined experimentally. Furthermore, the response of sandwich panels to quasi-static indentation and low velocity impact is examined to quantify the extent of damage and how it is affected by the integration of polyurethane interlayers in their construction. This information is useful in the modelling of high velocity impact of sandwich panels; an effort which is currently underway. The results illustrate the benefit of using polyurethane interlayers within the construction of sandwich panels in enhancing their performance under quasi-static indentation and impact loads

  16. Sound-proof Sandwich Panel Design via Metamaterial Concept

    Science.gov (United States)

    Sui, Ni

    Sandwich panels consisting of hollow core cells and two face-sheets bonded on both sides have been widely used as lightweight and strong structures in practical engineering applications, but with poor acoustic performance especially at low frequency regime. Basic sound-proof methods for the sandwich panel design are spontaneously categorized as sound insulation and sound absorption. Motivated by metamaterial concept, this dissertation presents two sandwich panel designs without sacrificing weight or size penalty: A lightweight yet sound-proof honeycomb acoustic metamateiral can be used as core material for honeycomb sandwich panels to block sound and break the mass law to realize minimum sound transmission; the other sandwich panel design is based on coupled Helmholtz resonators and can achieve perfect sound absorption without sound reflection. Based on the honeycomb sandwich panel, the mechanical properties of the honeycomb core structure were studied first. By incorporating a thin membrane on top of each honeycomb core, the traditional honeycomb core turns into honeycomb acoustic metamaterial. The basic theory for such kind of membrane-type acoustic metamaterial is demonstrated by a lumped model with infinite periodic oscillator system, and the negative dynamic effective mass density for clamped membrane is analyzed under the membrane resonance condition. Evanescent wave mode caused by negative dynamic effective mass density and impedance methods are utilized to interpret the physical phenomenon of honeycomb acoustic metamaterials at resonance. The honeycomb metamaterials can extraordinarily improve low-frequency sound transmission loss below the first resonant frequency of the membrane. The property of the membrane, the tension of the membrane and the numbers of attached membranes can impact the sound transmission loss, which are observed by numerical simulations and validated by experiments. The sandwich panel which incorporates the honeycomb metamateiral as

  17. Porous Sandwiched Graphene/Silicon Anodes for Lithium Storage

    International Nuclear Information System (INIS)

    Wei, Liangming; Hou, Zhongyu; Wei, Hao

    2017-01-01

    Highlights: • In situ hydrolysis of tetraethoxysilane within the confined galleries region of graphite oxide. • New porous sandwiched graphene/Si nanocomposites were prepared by magnesium thermal reduction. • The Si nanostructure was compactly sandwiched between two neighboring graphenes. • The Si/graphene anodes deliver large reversible capacity with excellent cycling stability. - Abstract: Porous sandwiched graphene/Si nanocomposites (PG-Si) are prepared by in situ hydrolysis of tetraethoxysilane within the confined gallery region of graphite oxide, and then magnesium thermal reduction of the intra-gallery SiO 2 to Si nanocrystals. The Si nanostructures are in situ formed within the confined gallery region of graphite, and they are compactly sandwiched between two neighboring graphene sheets. This compactly sandwiched structure affords enhanced electron conductivity, and prevents Si nanoparticles from aggregation. Meanwhile, the free voids between neighboring Si nanocrystals alleviate the volume change of Si during cycling. As a consequence, the resulting PG-Si nanocomposites are high-performance anode materials for lithium-ion batteries which show long cycle life (>500 cycles) and high specific charge capacity (1464 mAh g −1 at a current density of 200 mA/g, 920 mAh g −1 at a current density of 1.68A/g after 500 cycles). The Li + diffusion kinetics in PG-Si is also discussed.

  18. Sandwich mapping of schistosomiasis risk in Anhui Province, China.

    Science.gov (United States)

    Hu, Yi; Bergquist, Robert; Lynn, Henry; Gao, Fenghua; Wang, Qizhi; Zhang, Shiqing; Li, Rui; Sun, Liqian; Xia, Congcong; Xiong, Chenglong; Zhang, Zhijie; Jiang, Qingwu

    2015-06-03

    Schistosomiasis mapping using data obtained from parasitological surveys is frequently used in planning and evaluation of disease control strategies. The available geostatistical approaches are, however, subject to the assumption of stationarity, a stochastic process whose joint probability distribution does not change when shifted in time. As this is impractical for large areas, we introduce here the sandwich method, the basic idea of which is to divide the study area (with its attributes) into homogeneous subareas and estimate the values for the reporting units using spatial stratified sampling. The sandwich method was applied to map the county-level prevalence of schistosomiasis japonica in Anhui Province, China based on parasitological data collected from sample villages and land use data. We first mapped the county-level prevalence using the sandwich method, then compared our findings with block Kriging. The sandwich estimates ranged from 0.17 to 0.21% with a lower level of uncertainty, while the Kriging estimates varied from 0 to 0.97% with a higher level of uncertainty, indicating that the former is more smoothed and stable compared to latter. Aside from various forms of reporting units, the sandwich method has the particular merit of simple model assumption coupled with full utilization of sample data. It performs well when a disease presents stratified heterogeneity over space.

  19. Sandwich mapping of schistosomiasis risk in Anhui Province, China

    Directory of Open Access Journals (Sweden)

    Yi Hu

    2015-06-01

    Full Text Available Schistosomiasis mapping using data obtained from parasitological surveys is frequently used in planning and evaluation of disease control strategies. The available geostatistical approaches are, however, subject to the assumption of stationarity, a stochastic process whose joint probability distribution does not change when shifted in time. As this is impractical for large areas, we introduce here the sandwich method, the basic idea of which is to divide the study area (with its attributes into homogeneous subareas and estimate the values for the reporting units using spatial stratified sampling. The sandwich method was applied to map the county-level prevalence of schistosomiasis japonica in Anhui Province, China based on parasitological data collected from sample villages and land use data. We first mapped the county-level prevalence using the sandwich method, then compared our findings with block Kriging. The sandwich estimates ranged from 0.17 to 0.21% with a lower level of uncertainty, while the Kriging estimates varied from 0 to 0.97% with a higher level of uncertainty, indicating that the former is more smoothed and stable compared to latter. Aside from various forms of reporting units, the sandwich method has the particular merit of simple model assumption coupled with full utilization of sample data. It performs well when a disease presents stratified heterogeneity over space.

  20. Structure of an epiphytic hydroid community on Cystoseira at two sites of different wave exposure

    Directory of Open Access Journals (Sweden)

    Anuschka Faucci

    2000-12-01

    Full Text Available Epiphytism is a strategy by which opportunistic species such as hydroids, escape the intense levels of competition in marine hard bottom communities. Species of the macroalgae Cystoseira have a seasonal turnover of the frond, and we hypothesise that epiphytic hydroids colonising such an unstable substrate might show some degree of specialisation. Here the first systematic study on hydroid-Cystoseira communities is presented. In particular, the seasonal and spatial distribution of epiphytic hydroids on three species of Cystoseira at two sites of different wave exposure at Porto Cesareo (Ionian Sea/Italy were investigated. Thirty-two hydroid species were recorded which are well known from other substrates and thus are not specific to Cystoseira; dominant species were all thecates. The influence of biological factors such as competition and the structure and abundance of the host, seem to have little influence on the hydroid community. The factors of greatest influence were mostly abiotic: sedimentation rate, nutrient levels, temperature and most especially water movement. The importance of water movement was evident in the higher colonisation of algal stems, higher hydroid frequency, larger colonies, reduced colony height, species composition, and distribution on the stems at the wave-exposed site.

  1. Measurement of human tissue-type plasminogen activator by a two-site immunoradiometric assay

    International Nuclear Information System (INIS)

    Rijken, D.C.; Juhan-Vague, I.; De Cock, F.; Collen, D.

    1983-01-01

    A two-site immunoradiometric assay for human extrinsic (tissue-type) plasminogen activator was developed by using rabbit antibodies raised against plasminogen activator purified from human melanoma cell culture fluid. Samples of 100 μl containing 1 to 100 ng/ml plasminogen activator were incubated in the wells of polyvinyl chloride microtiter plates coated with antibody. The amount of bound extrinsic plasminogen activator was quantitated by the subsequent binding of 125 I-labeled affinospecific antibody. The mean level of plasma samples taken at rest was 6.6 +/- 2.9 ng/ml (n = 54). This level increased approximately threefold by exhaustive physical exercise, venous occlusion, or infusion of DDAVP. Extrinsic plasminogen activator in plasma is composed of a fibrin-adsorbable and active component (1.9 +/- 1.1 ng/ml, n = 54, in resting conditions) and an inactive component that does not bind to a fibrin clot (probably extrinsic plasminogen activator-proteinase inhibitor complexes). The fibrin-adsorbable fraction increased approximately fivefold to eightfold after physical exercise, venous occlusion, or DDAVP injections. Potential applications of the immunoradiometric assay are illustrated by the measurement of extrinsic plasminogen activator in different tissue extracts, body fluids, and cell culture fluids and in oocyte translation products after injection with mRNA for plasminogen activator

  2. Improvements in the automated radioimmunoassay for cAMP or cGMP

    International Nuclear Information System (INIS)

    Brooker, G.

    1988-01-01

    The work others in developing antibodies and the original radioimmunoassay for cyclic nucleotides provides the basis for these sensitive assays. The acetylation radioimmunoassay for cyclic nucleotides has enabled the measurement of cyclic AMP and cyclic GMP in very small biological samples. This is because accurate determinations can be made in samples containing less than 1 fmol of cyclic AMP or cyclic GMP. The Gamma-Flo automated radioimmunoassay system has been adapted to these assays such that cyclic nucleotides can be automatically measured at a rate of about 60 samples/hr. The Gamma-Flo instrument provides high-precision assays and eliminates human intervention in all steps of the radioimmunoassay. The automated assay has been in continuous operation in our laboratory over the last 10 years and this chapter summarizes the methodology and delineates improvements which have occurred over that time frame. Details for the preparation of the radioligands apply also to the manual acetylated radioimmunoassay for cyclic nucleotides

  3. Comparison of radioimmunoassay and gas chromatographic mass spectrometric assay for d-amphetamine

    International Nuclear Information System (INIS)

    Powers, K.H.; Ebert, M.H.

    1979-01-01

    Quantification of low levels of psychotropic drugs (10 -7 to 10 -9 g ml -1 ) in small volumes of plasma requires sensitive and accurate methods. Validation of these methods is best achieved by comparing results obtained using several techniques. In this study, amphetamine levels in plasma were measured using gas chromatography mass spectrometry and radioimmunoassay. Correlation of the results obtained by the two methods was found to be positive and high (R = 0.9822). The average coefficient of variation between assays for gas chromatography mass spectrometry was 5.8% and for radioimmunoassay was 12.3%, while the average coefficient of variation within assays for gas chromatography mass spectrometry was 4.9% and for radioimmunoassay 6.9%. Although gas chromatography mass spectrometry was 1.9 times more sensitive than radioimmunoassay, for most purposes, the convenience of the radioimmunoassay method outweighs the technical superiority of gas chromatography mass spectrometry. (author)

  4. A two-site immunoradiometric assay for human pregnancy-associated plasma protein A (PAPP-A) using monoclonal antibodies

    International Nuclear Information System (INIS)

    Mowles, E.A.; Pinto-Furtado, L.G.; Bolton, A.E.

    1986-01-01

    A rapid, sensitive immunoradiometric assay has been developed for human pregnancy-associated plasma protein A (PAPP-A) using a purified mouse monoclonal antibody as the tracer and a rabbit polyclonal antibody to this protein in the solid-phase antibody preparation. The assay showed no measurable cross-reaction (< 0.1%) against a range of purified human placental proteins, and a good correlation with a previously described radioimmunoassay procedure when tested on samples taken throughout normal human pregnancies. No PAPP-A-like immunological activity could be detected in sera from non-pregnant women, confirming the absence of this protein from the circulation outside pregnancy. (Auth.)

  5. Identification of material properties of sandwich structure with piezoelectric patches

    Directory of Open Access Journals (Sweden)

    Zemčík R.

    2008-11-01

    Full Text Available The work focuses on light-weight sandwich structures made of carbon-epoxy skins and foam core which have unique bending stiffness compared to conventional materials. The skins are manufactured by vacuum autoclave technology from unidirectional prepregs and the sandwich is then glued together. The resulting material properties of the structure usually differ from those provided by manufacturer or even those obtained from experimental tests on separate materials, which makes computational models unreliable. Therefore, the properties are identified using the combination of experimental analysis of the sandwich with attached piezoelectric transducer and corresponding static and modal finite element analyses. Simple mathematical optimization with repetitive finite element solution is used. The model is then verified by transient analysis when the piezoelectric patch is excited by harmonic signals covering the first two eigen-frequencies and the induced oscillations are measured by laser sensor.

  6. Nanocrystalline Aluminum Truss Cores for Lightweight Sandwich Structures

    Science.gov (United States)

    Schaedler, Tobias A.; Chan, Lisa J.; Clough, Eric C.; Stilke, Morgan A.; Hundley, Jacob M.; Masur, Lawrence J.

    2017-12-01

    Substitution of conventional honeycomb composite sandwich structures with lighter alternatives has the potential to reduce the mass of future vehicles. Here we demonstrate nanocrystalline aluminum-manganese truss cores that achieve 2-4 times higher strength than aluminum alloy 5056 honeycombs of the same density. The scalable fabrication approach starts with additive manufacturing of polymer templates, followed by electrodeposition of nanocrystalline Al-Mn alloy, removal of the polymer, and facesheet integration. This facilitates curved and net-shaped sandwich structures, as well as co-curing of the facesheets, which eliminates the need for extra adhesive. The nanocrystalline Al-Mn alloy thin-film material exhibits high strength and ductility and can be converted into a three-dimensional hollow truss structure with this approach. Ultra-lightweight sandwich structures are of interest for a range of applications in aerospace, such as fairings, wings, and flaps, as well as for the automotive and sports industries.

  7. Radioimmunoassay for detection of IgM domains

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, A [Osaka Univ. (Japan); Watanabe, S; Kiyotaki, C; Yamamura, Y

    1979-09-01

    IgM from two macroglobulinemia patients was digested with trypsin, and Fab monomer, Fab dimer and Fc fragments of the IgM were isolated. Using these fragments as antigens and rabbit antisera prepared against another IgM from a macroglobulinemia patient, a radioimmunoassay system for the C..mu..1, C..mu..2 and Fc..mu.. was established. This system can be used as a tool for immunochemical characterization of IgM present on the surface of lymphoid cells.

  8. Radioimmunoassay for antibodies against surface membrane antigens using adhering cells

    Energy Technology Data Exchange (ETDEWEB)

    Tax, A; Manson, L A [Wistar Inst. of Anatomy and Biology, Philadelphia, Pa. (USA)

    1976-07-01

    A radioimmunoassay using cells adhering to plastic is described. In this assay, A-10 mammary carcinoma attached to the surface of plastic in microtiter plates were permitted to bind antibody and the bound antibody was detected with purified rabbit /sup 125/I-antimouse-Fab. The bound radioactive material was eluted with glycine-HCl buffer (pH 2.5), and the acid eluates were counted in a gamma counter. This assay can be used to detect cytolic or noncytolic antibody to cell surface antigens in studies with any tumor or normal cell that will adhere to a solid surface.

  9. Radioimmunoassay for free and bound forms of abscisic acid

    Energy Technology Data Exchange (ETDEWEB)

    Cutting, J.G.; Hofman, P.J.; Wolstenholme, B.N. (Natal Univ., Pietermaritzburg (South Africa). Dept. of Horticultural Science); Lishman, A.W. (Natal Univ., Pietermaritzburg (South Africa). Dept. of Animal Science)

    1984-01-01

    A radioimmunoassay (RIA) for the quanitation of abscisic acid (ABA) has been developed. The assay is extremely sensitive and measuring ranges extend from 10 pg to 10 ng. Although the assay was free of contaminant interference when applied to avocado material, crude extract analysis yielded a composite of free and bound forms of ABA. Equivalents of 20 mg of plant material were spotted onto silica gel plates (GF/sup 245/ solvent:toluene:ethyl acetate : acetic acid 25:15:3), developed and the relative Rf zones removed and subjected to RIA. The technique was tested on avocados.

  10. Radioimmunoassay for free and bound forms of abscisic acid

    International Nuclear Information System (INIS)

    Cutting, J.G.; Hofman, P.J.; Wolstenholme, B.N.; Lishman, A.W.

    1984-01-01

    A radioimmunoassay (RIA) for the quanitation of abscisic acid (ABA) has been developed. The assay is extremely sensitive and measuring ranges extend from 10 pg to 10 ng. Although the assay was free of contaminant interference when applied to avocado material, crude extract analysis yielded a composite of free and bound forms of ABA. Equivalents of 20 mg of plant material were spotted onto silica gel plates (GF 245 solvent:toluene:ethyl acetate : acetic acid 25:15:3), developed and the relative Rf zones removed and subjected to RIA. The technique was tested on avocados

  11. Radioimmunoassay for determination of thyroglobulin in human serum

    International Nuclear Information System (INIS)

    Rodriguez Cabrera, M.E.; Blanca Fernandez, S.; Baldor Navarro, F.; Rodriguez Gonzalez, J.C.

    1996-01-01

    We described the development and analytical evaluation of a radioimmunoassay with double antibody in liquid phase for human serum thyroglobulin determination using a set of reagents produced in the National Institute of Endocrinology. The reference interval for normal population was 5.7 - 44 ng/ml (X± 2DS; n=170). The intra-assay precipision was 8.1 % (control serum A) and 7.0 (control serum B) and the inter-assay precision was 9.1 % (control serum A) and 9.2 % (control serum B). The sensibility was 4.7 ng/ml and the recovery was 95 %

  12. Radioimmunoassay of human muscle carbonic anhydrase III in dystrophic states

    Energy Technology Data Exchange (ETDEWEB)

    Heath, R.; Jeffery, S.; Carter, N. (Department of Child Health, St. George' s Hospital Medical School, London (UK))

    1982-03-12

    A radioimmunoassay for the human isozyme carbonic anhydrase III (CAIII) has been developed. The assay can detect levels as low as 4..mu..g/l of sample. Plasma CAIII levels in patients suffering from Duchenne muscular dystrophy were found to be up to 39 times greater than in a control group. Urine CAIII levels in patients suffering from Duchenne muscular dystrophy were not significantly different from the levels found in urine from normal adults. Measurement of plasma CAIII levels may be useful in prenatal diagnosis of Duchenne muscular dystrophy, and in investigation of adult skeletal muscle disease.

  13. Radioimmunoassay of human muscle carbonic anhydrase III in dystrophic states

    International Nuclear Information System (INIS)

    Heath, R.; Jeffery, S.; Carter, N.

    1982-01-01

    A radioimmunoassay for the human isozyme carbonic anhydrase III (CAIII) has been developed. The assay can detect levels as low as 4μg/l of sample. Plasma CAIII levels in patients suffering from Duchenne muscular dystrophy were found to be up to 39 times greater than in a control group. Urine CAIII levels in patients suffering from Duchenne muscular dystrophy were not significantly different from the levels found in urine from normal adults. Measurement of plasma CAIII levels may be useful in prenatal diagnosis of Duchenne muscular dystrophy, and in investigation of adult skeletal muscle disease. (Auth.)

  14. Intrinsic factor in human amniotic fluid as determined by radioimmunoassay

    International Nuclear Information System (INIS)

    Wahlstedt, V.; Stenman, U.-H.; Ylinen, K.; Graesbeck, R.

    1983-01-01

    The intrinsic factor (IF) concentration in 55 human amniotic fluid specimens was determined by radioimmunoassay (RIA). The antiserum was produced by immunizing rabbits with the cobalamin-IF complex isolated from human gastric juice. The median concentration of IF was 0.17 nmol/l and the extreme values <0.07-2.51 nmol/l. Three specimens with a clearly elevated level (0.96, 1.11 and 2.51 nmol/l) were observed. The highest value was associated with a fetal malformation, viz. obstruction of the proximal gut. There was no evident correlation between the concentration of IF in amniotic fluid and gestational age. (author)

  15. Investigations of serum HPL during pregnancy using two different radioimmunoassays

    International Nuclear Information System (INIS)

    Stracke, H.

    1978-01-01

    The interassay investigations showed that it is absolutely necessary to standardize the HPL antisera as well as the standard sera, as it is otherwise impossible to compare and interpret the findings of different HPL radioimmunoassays. The investigations have shown that in addition to conventional clinical examinations and laboratory test methods (urine estriol determination, DHEAS-dehydroepiandrosterone sulphate test-, urine pregnandiol determination, and determination of heat-resisting alkaline serum phosphatase), HPL concentration determination is a parameter of the nutritive function of the placenta. (orig.) [de

  16. Studies on digoxin derivatives in different biological media by radioimmunoassay

    International Nuclear Information System (INIS)

    Barmasch, Martha; Perez, L.N.; Altschuler, Noe.

    1978-05-01

    The fundamental aim of this study was to develop a methodology to be applied to pharmacological studies, directed to demonstrate the passage of digitalic compounds through the blood-brain barrier. This study was a comparative one between β methyl digoxin (βMD) and digitoxin (Dt). A methodology of radioimmunoassay was developed for different biological media: serum (S), plasma (P) and cerebro spinal fluid (CSF). In addition, the immunochemical behaviour (affinity, displacement, etc.) of βMD was studied when reacted with digoxin (D) and digoxin-antisera, supplied by the commercial kits utilized in these studies. (author) [es

  17. An introduction to radioimmunoassay and related techniques. 3. rev. ed.

    International Nuclear Information System (INIS)

    Chard, T.

    1987-01-01

    This book is designed as an introductory text for the staff of clinical or research laboratories who conduct or intend to conduct radioimmunoassay and related immunoassay techniques, and will also be of great value to the clinicians who make use of such services. The emphasis is on general principles with practical illustrations rather than a detailed and encyclopaedic review of the literature. This 3rd revised edition places more emphasis on alternative labels (non-isotopic immunoassays), the use of labelled antibodies (immunometric assays), and the use of monoclonal antibodies. Both principles and practice are illustrated by diagrams and illustrations. (Auth.)

  18. Isotopic methods or immuno diagnosis: The Radioimmunoassay and immunoradiometric assay

    International Nuclear Information System (INIS)

    Caso, R.

    1997-01-01

    This work offers an explanation about the more used isotopic techniques for immuno diagnosis: the radioimmunoassay (RIA) and immunoradiometric assay (IRMA). It describes the basic principles of these assays, the antigen-antibody reaction, the radioiodination methods with I-125 for antigens and antibodies, the purification and characterization of labelled compounds. On the order hand they present work gives a review of the methods for separate the bound and free fractions. At the end it offers the principles of the quality control of immunoassay and the future lines of research in the field of RIA and IRMA

  19. Triiodothyronine radioimmunoassay. Comparison of the different factors between two technics

    International Nuclear Information System (INIS)

    Gehin-Fouque, F.; Etling, N.; Pradelles, P.; Bornet, H.

    1980-01-01

    Triiodothyronine concentration was determined in human serum and in thyroid extracts by two radioimmunoassay technics. Both antibodies, radioactive T 3 , stable T 3 , protein-binding-hormone inhibitors, methods used to separate the free from the bound fractions were different. Each factor from a method was substituted to the homologue of the other method. The results occasionnally showed a variation of 32% in the first method and 50% in the second one. However the results gave a correct interpretation of the triiodothyronine values measured in human serum and in thyroid extracts [fr

  20. Radioimmunoassay of serum β2-microglobulin in donor's blood

    International Nuclear Information System (INIS)

    Yin Shihua; Song Shiyun; Li Kelin; Chen Guanglian; Liu Fengmin

    1993-01-01

    Serum β 2 -microglobulin (β 2 -MG) was tested by radioimmunoassay in 149 donors' and 54 healthy volunteers' blood. The results were 203 +- 33.0 nmol/l and 176 +- 26.2 nmol/l, respectively. There was significant difference statistically between them (P 2 -MG content. In order to increase the quality of donated blood and to keep the health of blood donor, it is suggested that the high content of serum β 2 -MG is the indicator of too frequent blood donating. The results also showed that the content of β 2 -MG in donor's blood is not a normal reference value

  1. Radioimmunoassay for prostatic acid phosphatase in human serum. Methodologic aspects

    Energy Technology Data Exchange (ETDEWEB)

    Pradalier, N; Canal, P; Pujol, A; Fregevu, Y [Groupe de Recherches du Centre Claudius-Regaud, Toulouse (France); Soula, G [Faculte des Sciences Pharmaceutiques, Toulouse (France)

    1982-01-01

    We propose a double antibody radioimmunoassay for human prostatic acid phosphatase (PAP) in serum for diagnosis and management of prostatic adenocarcinoma under treatment. The antigen is purified from human prostatic fluid by a gel-filtration on Sephadex G 100 followed by affinity chromatography on Con A Sepharose. A specific antibody is raised in rabbits and purified by immunoadsorption with a female serum. The described technique offers both radioisotopic sensibility and immunologic specificity. Physiological values determined in the serum of 125 healthy males are below 2 ng/ml. No significative differences are observed with age. The proposed technique also shows significant differences between values evaluated for benign prostatic hyperplasia and prostatic adenocarcinoma.

  2. Radioimmunoassay for the detection of Australia-SH antigen

    Energy Technology Data Exchange (ETDEWEB)

    Gerhardt, H [Giessen Univ. (Germany, F.R.). Zentrum fuer Innere Medizin

    1974-06-01

    Among infectious diseases, hepatitis presents a great problem in all countries with a high medical standard. The number of Australia antigen-positive cases rises from year to year, due to the increase in drug-fixer hepatitis and blood transfusions. Highly sensitive and at the same time practicable methods are therefore required for the identification of Australia antigen carriers and their elimination as blood donors. The most sensitive of all currently used tests for the detection of Australia antigen is the 'solid phase' radioimmunoassay since it permits an objective and quantitative measurement of the antigen.

  3. Quality control in radioimmunoassay for Argentina, Chile, Paraguay and Uruguay

    International Nuclear Information System (INIS)

    Quiroga, S.

    1984-10-01

    The purpose of this project was the development of an External Quality Control Programme on Radioimmunoassay among laboratories from Argentina and other Latinoamerican countries. The purpose of this programme was to improve the performance of the participating laboratories in order to increase the diagnostic value of patient results. The number of returns of this programme (Buenos Aires I) were compared against those of the previous one (Programme I) (Contract 2737/RB) to determine if the objectives were fulfilled. The preparation of the samples and the evaluation of the results of the first six samples were analyzed in the progress report sent on December 30th, 1983 and were reanalysed including late results

  4. Use of radioimmunoassay to diagnose some forms of endocrine sterility

    International Nuclear Information System (INIS)

    Balabolkin, M.I.; Gerasimov, G.A.

    1984-01-01

    The possibility is considered of using a metoclopramide test combined with radioimmunoassay for determing prolactin in the blood to diagnose some forms of endocrine sterility Of 17 women examined 5 are practically healthy, sterility of 6 women is caused by tumor of hypophysis verified by X-rayograms, 6 women suffered from disorderded prolactin secretion and sterility without roentgenologic signs of disordered sella turcica. Metoclopramide has been injected intravenously in the 10 mm dose. A series of advantages is noted of the metoclopramide sample characteristic of high availability of the preparation and practically complete absence of side-effects

  5. Radioimmunoassay of somatostatin: methodological problems and physiological investigations

    International Nuclear Information System (INIS)

    Penman, E.; Wass, J.A.H.

    1981-01-01

    Somatostatin, a tetradecapeptide, has a wide distribution throughout the central nervous system and the gastrointestinal tract and a broad spectrum of biological actions. In order to investigate its various physiological roles in man, a radioimmunoassay was developed for somatostatin in human blood plasma, which is described here. This RIA was used to investigate possible factors influencing somatostatin secretion. Changes in somatin levels produced by changes in insulin, glucagon and growth hormone levels were studied via the response of plasma immunoreactive somatostatin to hormonal stimuli in normal man. The influence of fasting and food consumption was studied; and the site of origin of circulating immunoreactive somatostatin was investigated in patients. (Auth.)

  6. Radioimmunoassay test system for detection of anti-insulin antibodies

    International Nuclear Information System (INIS)

    Dudko, N.V.; Piven', N.V.; Ibragimova, G.V.; Kasatkin, Yu.N.

    1995-01-01

    A radiodiagnostic test system has been developed and commercial kit for radioimmunoassay of anti-insulin antibodies in human blood serum created. Clinical trials of the kit in patients (150 diabetics with types 1 and 2 condition) and normal subjects (n=100) demonstrated the possibility of using this kit for the detection of preclinical forms of diabetes and for distinguishing groups at risk of diabetes among children and adults, for the detection of insulin resistance, for the differential diagnosis of diabetes, and for monitoring the efficacy of insulin therapy. 9 refs.; 1 tab

  7. Radioimmunoassay and radioenzymatic assay of a new aminoglycoside antibiotic, netilmicin

    International Nuclear Information System (INIS)

    Broughton, A.; Strong, J.E.; Pickering, L.K.; Knight, J.; Bodey, G.P.

    1978-01-01

    A radioimmunoassay and a radioenzymatic assay for netilmicin, a new aminoglycoside, were developed in our laboratories to assist in the study of the pharmacology of the drug and establish values for use in its monitoring. The assays are sensitive, precise, and rapid, giving results that correlate (r = 0.90) with each other and with those of a microbiological assay in which Klebsiella pneumoniae is used as the test organism. Preliminary pharmacological studies show the drug to have a biological half-life of 135 min, which is comparable to that for other aminoglycosides

  8. Radioimmunoassay of plasma cortisol and its clinical application

    International Nuclear Information System (INIS)

    Ninomiya, Tetsuhiro; Ishitobi, Kazuyuki; Harada, Yoshimichi

    1975-01-01

    A system for the radioimmunoassay of plasma cortisol was developed together with a nonchromatographic method for the assay. An anti-cortisol serum, produced by immunization of rabbits with cortisol-21-hemisuccinate-BSA, proved to have a high affinity and a high specificity for cortisol. The results determined by this system were satisfactory. The nonchromatographic method correlated well with the chromatographic one in normal subjects, who showed 66.2 +- 34.8 ng/ml (case number 22) plasma cortisol levels from 9:00 to 10:00 AM. Various provocation tests were applied to normal subjects and to patients with endocrine disease, and the results were discussed. (auth.)

  9. Radioimmunoassay of human β-lipotropin in unextracted plasma

    International Nuclear Information System (INIS)

    Wiedemann, E.; Saito, T.; Linfoot, J.A.; Li, C.H.

    1977-01-01

    A sensitive and specific radioimmunoassay for human β-lipotropin (β/sub h/-LPH) in unextracted plasma was developed using pure β/sub h/-LPH as tracer and standard and an antiserum not cross-reacting with human β-MSH and hACTH. In healthy volunteers plasma β/sub h/-LPH ranged from <20 to 150 pg/ml at 8:00 a.m. and rose after metyrapone administration. β/sub h/-LPH was very low in panhypopituitarism, normal in most patients with untreated Cushing's disease, elevated in acromegaly and extremely high in Nelson's syndrome

  10. Direct measurement of human plasma corticotropin-releasing hormone by two-site immunoradiometric assay

    International Nuclear Information System (INIS)

    Linton, E.A.; McLean, C.; Nieuwenhuyzen Kruseman, A.C.; Tilders, F.J.; Van der Veen, E.A.; Lowry, P.J.

    1987-01-01

    A ''two-site'' immunoradiometric assay (IRMA) which allows the direct estimation of human CRH (hCRH) in plasma is described. Using this IRMA, basal levels of CRH in normal subjects ranged from 2-28 pg/mL [mean, 15 +/- 7 (+/- SD) pg/mL; n = 58]. Values in men and women were similar. Plasma CRH values within this range were also found in patients with Cushing's syndrome, Addison's disease, and Nelson's syndrome, with no correlation between plasma CRH and ACTH levels in these patients. Elevated plasma CRH levels were found in pregnant women near term [1462 +/- 752 (+/- SD) pg/mL; n = 55], and the dilution curve of this CRH-like immunoreactivity paralleled the IRMA standard curve. After its immunoadsorption from maternal plasma, this CRH-like material eluted on reverse phase high performance liquid chromatography with a retention time identical to that of synthetic CRH and had equipotent bioactivity with the synthetic peptide in the perfused anterior pituitary cell bioassay. Circulating CRH was not detected in Wistar rats, even after adrenalectomy and subsequent ether stress. Synthetic hCRH was degraded by fresh human plasma relatively slowly; 65% of added CRH remained after 1 h of incubation at 37 C. Degradation was inhibited by heat treatment (54 C; 1 h), cold treatment (4 C; 4 h), or freezing and thawing. Loss of synthetic rat CRH occurred more rapidly when fresh rat plasma was used; only 20% of added CRH remained under the same conditions. The inability to measure CRH in peripheral rat plasma may be due to the presence of active CRH-degrading enzymes which fragment the CRH molecule into forms not recognized by the CRH IRMA

  11. Tailoring Sandwich Face/Core Interfaces for Improved Damage Tolerance

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Berggreen, Christian; Carlsson, Leif A.

    2010-01-01

    Various modifications of the face/core interface in foam core sandwich specimens are examined in a series of two papers. This paper constitutes part I and describes the finite element analysis of a sandwich test specimen, i.e. a DCB specimen loaded by uneven bending moments (DCB-UBM). Using...... this test almost any mode-mixity between pure mode I and mode II can be obtained. A cohesive zone model of the mixed mode fracture process involving large-scale bridging is developed. Results from the analysis are used in Part II, which describes methods and results of a series of experiments....

  12. Calculation of dynamic stresses in viscoelastic sandwich beams using oma

    DEFF Research Database (Denmark)

    Pelayo, F.; Aenlle, M. L.; Ismael, G.

    2017-01-01

    The mechanical response of sandwich elements with viscoelastic core is time and temperature dependent. Laminated glass is a sandwich element where the mechanical behavior of the glass layers is usually considered linear-elastic material whereas the core is made of an amorphous thermoplastic which...... data. In simple structures, analytical mode shapes can be used alternatively to the numerical ones. In this paper, the dynamic stresses on the glass layers of a laminated glass beam have estimated using the experimental acceleration responses measured at 7 points of the beam, and the experimental mode...

  13. Friction stir welding (FSW of aluminium foam sandwich panels

    Directory of Open Access Journals (Sweden)

    M. Bušić

    2016-07-01

    Full Text Available The article focuses on the influence of welding speed and tool tilt angle upon the mechanical properties at the friction stir welding of aluminium foam sandwich panels. Double side welding was used for producing butt welds of aluminium sandwich panels applying insertion of extruded aluminium profile. Such insertion provided lower pressure of the tool upon the aluminium panels, providing also sufficient volume of the material required for the weldment formation. Ultimate tensile strength and flexural strength for three-point bending test have been determined for samples taken from the welded joints. Results have confirmed anticipated effects of independent variables.

  14. The development of a general solid-phase radioimmunoassay method. Application to follicle stimulating hormone and to luteinizing hormone radioimmunoassays

    International Nuclear Information System (INIS)

    Fleury, B.

    1981-10-01

    A solid phase method of radioimmunoassay utilizing a second antibody adsorbed onto tubes was developed. Polyethylene tubes were selected for their adsorption capacity. The following topics were emphasized: the rate of labelled antigen uptake on the second antibody adsorbed on the tubes through the medium of the first antibody; the influence of the second antibody on the antigen-first antibody reaction and comparison with the immunoprecipiting technique; the various factors able to influence the calibration curve and applications to assay optimization; the performances of hFSH AND hLH assays [fr

  15. Measurement of alpha-fetoprotein in maternal serum: three commercial radioimmunoassay kits and two non-commercial radioimmunoassays compared

    International Nuclear Information System (INIS)

    Forest, J.C.; Verreault, F.; Pouliot, M.

    1982-01-01

    We evaluated three commercial radioimmunoassay kits (Amersham, Dainabot, Clinical Assays) and two non-commercial methods for determining alpha-fetoprotein in maternal serum during pregnancy. All five procedures were found to be acceptable with respect to practicability, sensitivity, linearity, and precision. Similar results were obtained with Dainabot, Clinical Assays, and the two non-commercial methods, but the Amersham method revealed a proportional error, results being about 20% lower than those by the other methods. Use of the international unit system is suggested for reporting results for AFP, to facilitate comparison between methods and laboratories

  16. Application of fibre reinforced plastic sandwich structures for automotive crashworthiness applications

    NARCIS (Netherlands)

    Lukaszewicz, D.; Blok, L.G.; Kratz, J.; Ward, C.; Kassapoglou, C.; Elmarakbi, A.; Araújo, A.L.

    2016-01-01

    In this work the application of fibre reinforced plastic (FRP) sandwich
    structures, with particular focus on aramid fibre tufted sandwiches is being studied for
    automotive crashworthiness applications using impact testing and numerical simulation.

  17. Robust and Air-Stable Sandwiched Organo-Lead Halide Perovskites for Photodetector Applications

    KAUST Repository

    Mohammed, Omar F.; Banavoth, Murali; Saidaminov, Makhsud I.; Abdelhady, Ahmed L.; Pan, Jun; Liu, Jiakai; Peng, Wei; Bakr, Osman

    2016-01-01

    We report the simplest possible method to date for fabricating robust, air-stable, sandwiched perovskite photodetectors. Our proposed sandwiched structure is devoid of electron or hole transporting layers and also the expensive electrodes

  18. Secretin-radioimmunoassay, physiology and pathophysiology in man

    International Nuclear Information System (INIS)

    Haecki, W.H.

    1978-01-01

    Production of antibodies to secretin for radioimmunoassay is straightforward. Secretin is iodinated by weak oxydation with lactoperoxydase and subsequent purification by ionexchange chromatography (Sephadex C25). The specific activity of fresh label is between 650 and 900 mCi x mol -6 . The label is highly purified and may be used in radioimmunoassay for several months. In order to eliminate plasma interference sepharose-beads with covalently coupled secretin antibodies are used to produce secretin-free standard plasma samples. Delay in the separation of plasma from fresh blood samples can lead to erronous results, even to falsely elevated secretin levels. - Duo-denal acidification only leads to physiological increases of secretin plasma levels. This may happen by intraduodenal instillation of acid, or by an acidic oral drink, or to a lesser extent after a meal. Secretin is distributed throughout the plasma volume and has a short halflife of around 3 minutes. Impaired release of secretin is found in children with coeliac disease. The role of secretin in peptic ulcer however is not clear. Chronic pancreatitis and renal insufficiency are without effect on plasma secretin levels. (orig.) [de

  19. A radioimmunoassay for equilin in equine pregnancy plasma

    International Nuclear Information System (INIS)

    Park, B.K.; Rance, Th.A.; Dean, P.D.G.

    1976-01-01

    It is well known that the pregnant mare produces large quantities of the ring B unsaturated steroid equilin in addition to classical oestrogens. However, the precise biogenesis of this unusual steroid remains a mystery. To facilitate a study of the interrelationship of the steroids present during equine pregnancy, a radioimmunoassay for the measurement of equilin in peripheral plasma was developed. As equilin is thought to be a product of the foeto-placental unit, such an assay may also be of use as an index of foetal well-being. Oestrone and equilin are present in similar concentrations in equine pregnancy plasma so it was important that an antiserum was produced which could differentiate between these two steroids. An antigen was synthesised in which equilin is linked to a protein carrier through the 17-position in order that the C 7 -C 8 double bond might be fully exposed for immune recognition. This stratagem proved successful as the antiserum obtained gave a cross-reaction of only 7.3% for oestrone. The use of a radioimmunoassay incorporating this antiserum is demonstrated by measuring equilin concentrations in plasma samples taken from a mare at weekly intervals from day 60 of pregnancy through to parturition. The corresponding oestrone concentrations are also recorded and demonstrate the validity of the equilin assay in this situation

  20. Radioimmunoassay of Alb, β2-M and THP

    International Nuclear Information System (INIS)

    Xie Zhiyuan; Li Shengqi; Ren Shusheng; Chen Yuying

    1993-01-01

    The combined determination of β 2 -M, THP, Alb, IgG may be used as the sensitive indication of the early degeneration of kidney function. The authors observed 107 cases, and found that the anomalous examine-out ratios of hemorrhage β 2 -M and UTHP are 50.75% and 65.67% respectively, 1.5-2.3 times higher than the C cr animals examine-out ratio. The radio-immunoassay of β 2 -M and THP is a better measure for discovering light kidney function injury in early period than C cr method. The clinical value of the radio-immunoassay of β 2 -M, THP is obviously better than the traditional and classical method. The diseases of anybody system may influence the kidney function through various mechanisms. The retrogression of kidney tissue of the patients in old-and mid-age leads to decrease of kidney function. The combination of β 2 -M and THP has the highest anomalous examine-out ratios of kidney function; the next is urine Alb

  1. Radioimmunoassay of human cardiac tropomyosin in acute myocardial infarction

    International Nuclear Information System (INIS)

    Cummins, P.; McGurk, B.; Littler, W.A.

    1981-01-01

    Tropomyosin was prepared from fresh human myocardium and antisera raised in rabbits. A sensitive radioimmunoassay was developed for the detection of human cardiac 125 I-labelled tropomyosin in human sera down to levels of 1 ng/ml. Values for human cardiac tropomyosin in normal patients ranged from less than 1 to 3 ng/ml. In 18 patients with acute myocardial infarction all had elevated tropomyosin levels ranging from 41 to above 200 ng/ml with a mean peak level of 101 ng/ml. In this study there were no false positive or false negative results. In the initial stages of infarction the time course of appearance and peak levels of cardiac tropomyosin, total creatine kinase and creatine kinase MB isoenzyme were similar. Although total creatine kinase and creatine kinase MB isoenzyme levels were normal after 72 h in patients with single, uncomplicated infarction, cardiac tropomyosin levels were still significantly elevated above normal after this time, being 30-60% of peak values. Radioimmunoassay of human cardiac tropomyosin may prove useful in the diagnosis and in the management of patients with acute myocardial infarction, particularly in the long-term postinfarction period. (author)

  2. Radioimmunoassay of TSH subunits in thyroid diseases and endocrine opthalmopahty

    International Nuclear Information System (INIS)

    Eder, W.

    1982-01-01

    Highly sensitive radioimmunoassays of hTSH sub-units were developed. The hormone preparations were labelled with 125-iodine according to a modified chloramine -T method, and purified by chromatography using biogel P6 and P60. Rabbit antisera were used as antibodies. Separation of the antibody-bound and of the free antigens was carried out via the double antibody method. The antiserum required for this purpose was obtained from a goat. The sensitivity of the assay was influenced by changing the protein content of the buffer, the incubation volume, the tracer amounts, the incubation time and the incubation temperature. For hTSH-α, the lowest detectable limit was found to be 50 pg/ml, for hTSH-#betta# 20 pg/ml. Thus, the sub-units could be determined for 98% of the patients under review. The #betta#-TSH radioimmunoassay is largely specific, TSH cross-reacts to a degree of 5%. The computerized evoluation was carried out by means of Spline approximation using the Siemens 4004 computer. Precision and accurateness are in compliance with generally accpted criteria. The serum levels of α and #betta# sub-units showed no discordancy with regard to TSH. In all groups of patients examined, the levels of the hormone-specific #betta#-chain were found to be exclusively dependent upon the actual thyroid activity. (orig.) [de

  3. The Principle and the Method of the Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Kunio [Dainabot Radioisotope Laboratory, Tokyo (Japan)

    1970-03-15

    The measurements of the amounts of various hormones in the body is one of the most important subjects in the field of endocrinology. The result obtained is not only helpful for the basic studies, such as the function studies of each organ or their interrelationship, but also valuable for routine clinical diagnosis. For the most of peptide hormones or protein hormones, a chemical measurement is very difficult. Biological methods are mostly utilized for this purpose but are not always satisfactory. The use of labeled hormone in combination with its antiserum led to the highly specific and sensitive measurement of the hormone in human plasma. This method is based essentially on the principle of isotope dilution method and is called radioimmunoassay. From the nuclear medical aspect, this is now one of the major fields of in vitro assay with radioisotope. With this method, less than 1 micro unit of insulin per ml of serum can be detected. In this lecture, I would like to talk about the principle and the method of the radioimmunoassay.

  4. Analysis of an iodide radioimmunoassay for 11-deoxicortisol measurement

    International Nuclear Information System (INIS)

    Madeira, Joao Luiz de Oliveira; Bussmann, Luciane Zgoda; Lima-Valassi, Helena Panteliou; Mendonca, Berenice Bilharinho de

    2014-01-01

    Objective: our aim was to correlate 11-deoxycortisol levels obtained by two currently available techniques for 11-deoxycortisol measurement: radioimmunoassay, and high performance liquid chromatography followed by tandem mass spectrometry (MS/MS). The latter is the gold standard method for steroid hormone measurement. Materials and methods: we selected 88 samples and the results of these two methods were compared by Deming regression. Results: the analytical sensitivity of the RIA was 0.30 ng/mL, with inadequate linearity and inadequate precision profile (34% of the samples had a CV ≥ 20%). From the selected samples, 54 had measurable levels of 11-deoxycortisol in both methods and were used in the comparison. The comparison of RIA with LC-MS/MS showed an overestimation of the results by RIA. The correlation coefficient was 0.610; linear regression slope was 3.751; and the intercept was 0.145, indicating a poor correlation between the two methods. Conclusion: we concluded that 11-deoxycortisol measured by radioimmunoassay, despite a good analytical sensitivity, showed very low specificity, precluding its use as a reliable method for 11-deoxycortisol measurement. (author)

  5. Radioimmunoassay of prostaglandin F in plasma of pregnant women

    International Nuclear Information System (INIS)

    Albert, P.

    1980-01-01

    The aim of this dissertation was to determine quantitatively prostaglandin-F in the plasma of pregnant women in order to obtain further knowledge on changes in PG-F during pregnancy, in particular during the last three months. The plasma of women with clinically normal pregnancies was taken. Prior to radioimmunoassay the plasma was extracted (separation of PG from other plasma components) and chromatography carried out (group separation of PG). The efficiency of this process, as measured by the recovery rate of 3 H-PGF, lies between 60.99% and 93.01% for extraction and between 80.58% and 92.16% for chromatography. The plasma was extracted and analysed chromatographically for the assay. The radioimmunoassay was carried out according to the procedure recommended by the manufacturer. A calibration curve was produced without difficulty. The results of the examination of plasma samples were unsatisfactory because of the low sensitivity of the assay; PG-F values of the same order were obtained for all weeks of pregnancy. (orig./MG) [de

  6. Gravity sag of sandwich panel assemblies as applied to precision cathode strip chamber structural design

    International Nuclear Information System (INIS)

    Horvath, J.

    1993-01-01

    The relationship between gravity sag of a precision cathode strip chamber and its sandwich panel structural design is explored parametrically. An algorithm for estimating the dominant component of gravity sag is defined. Graphs of normalized gravity sag as a function of gap frame width and material, sandwich core edge filler width and material, panel skin thickness, gap height, and support location are calculated using the gravity sag algorithm. The structural importance of the sandwich-to-sandwich ''gap frame'' connection is explained

  7. Solution of the effective Hamiltonian of impurity hopping between two sites in a metal

    Science.gov (United States)

    Ye, Jinwu

    1997-07-01

    We analyze in detail all the possible fixed points of the effective Hamiltonian of a nonmagnetic impurity hopping between two sites in a metal obtained by Moustakas and Fisher (MF). We find a line of non-Fermi liquid fixed points which continuously interpolates between the two-channel Kondo fixed point (2CK) and the one-channel, two-impurity Kondo (2IK) fixed point. There is one relevant direction with scaling dimension 12 and one leading irrelevant operator with dimension 32. There is also one marginal operator in the spin sector moving along this line. The marginal operator, combined with the leading irrelevant operator, will generate the relevant operator. For the general position on this line, the leading low-temperature exponents of the specific heat, the hopping susceptibility and the electron conductivity Cimp,χhimp,σ(T) are the same as those of the 2CK, but the finite-size spectrum depends on the position on the line. No universal ratios can be formed from the amplitudes of the three quantities except at the 2CK point on this line where the universal ratios can be formed. At the 2IK point on this line, σ(T)~2σu(1+aT3/2), no universal ratio can be formed either. The additional non-Fermi-liquid fixed point found by MF has the same symmetry as the 2IK, it has two relevant directions with scaling dimension 12, and is therefore also unstable. The leading low-temperature behaviors are Cimp~T,χhimp~lnT,σ(T)~2σu(1+aT3/2) no universal ratios can be formed. The system is shown to flow to a line of Fermi-liquid fixed points which continuously interpolates between the noninteracting fixed point and the two-channel spin-flavor Kondo fixed point discussed by the author previously. The effect of particle-hole symmetry breaking is discussed. The effective Hamiltonian in the external magnetic field is analyzed. The scaling functions for the physical measurable quantities are derived in the different regimes; their predictions for the experiments are given. Finally

  8. Fatigue failure of sandwich beams with face sheet wrinkle defects

    DEFF Research Database (Denmark)

    Leong, Martin Klitgaard; Hvejsel, C.F.; Thomsen, Ole Thybo

    2012-01-01

    This paper presents experimental fatigue results for GFRP face sheet/balsa core sandwich beams with face sheet wrinkle defects, subjected to fully reversed in-plane fatigue loading. An estimate of the fatigue design limit is presented, based on static test results, finite element analyses and app...

  9. Compressive Behaviour and Energy Absorption of Aluminium Foam Sandwich

    Science.gov (United States)

    Endut, N. A.; Hazza, M. H. F. Al; Sidek, A. A.; Adesta, E. T. Y.; Ibrahim, N. A.

    2018-01-01

    Development of materials in automotive industries plays an important role in order to retain the safety, performance and cost. Metal foams are one of the idea to evolve new material in automotive industries since it can absorb energy when it deformed and good for crash management. Recently, new technology had been introduced to replace metallic foam by using aluminium foam sandwich (AFS) due to lightweight and high energy absorption behaviour. Therefore, this paper provides reliable data that can be used to analyze the energy absorption behaviour of aluminium foam sandwich by conducting experimental work which is compression test. Six experiments of the compression test were carried out to analyze the stress-strain relationship in terms of energy absorption behavior. The effects of input variables include varying the thickness of aluminium foam core and aluminium sheets on energy absorption behavior were evaluated comprehensively. Stress-strain relationship curves was used for energy absorption of aluminium foam sandwich calculation. The result highlights that the energy absorption of aluminium foam sandwich increases from 12.74 J to 64.42 J respectively with increasing the foam and skin thickness.

  10. Outcome of the TURP-TUVP sandwich procedure for minimally ...

    African Journals Online (AJOL)

    Bladder neck stenosis occurred in 3 patients and was successfully treated with bladder neck incision. Conclusions: The sandwich combination of TURP and TUVP for the surgical treatment of BPH with volume larger than 40cc had satisfactory patient safety profile and resulted in significant improvement in IPSS, Qmax and ...

  11. Acoustic wave spread in superconducting-normal-superconducting sandwich

    International Nuclear Information System (INIS)

    Urushadze, G.I.

    2004-01-01

    The acoustic wave spread, perpendicular to the boundaries between superconducting and normal metals in superconducting-normal-superconducting (SNS) sandwich has been considered. The alternate current flow sound induced by the Green function method has been found and the coefficient of the acoustic wave transmission through the junction γ=(S 1 -S 2 )/S 1 , (where S 1 and S 2 are average energy flows formed on the first and second boundaries) as a function of the phase difference between superconductors has been investigated. It is shown that while the SNS sandwich is almost transparent for acoustic waves (γ 0 /τ), n=0,1,2, ... (where τ 0 /τ is the ratio of the broadening of the quasiparticle energy levels in impurity normal metal as a result of scattering of the carriers by impurities 1/τ to the spacing between energy levels 1/τ 0 ), γ=2, (S 2 =-S 1 ), which corresponds to the full reflection of the acoustic wave from SNS sandwich. This result is valid for the limit of a pure normal metal but in the main impurity case there are two amplification and reflection regions for acoustic waves. The result obtained shows promise for the SNS sandwich as an ideal mirror for acoustic wave reflection

  12. Examination of Sandwich Materials Using Air-Coupled Ultrasonics

    DEFF Research Database (Denmark)

    Borum, K.K.; Berggreen, Carl Christian

    2004-01-01

    The air-coupled ultrasonic techniques have been improved drastically in recent years. Better equipment has made this technique much more useful. This paper focuses on the examination of sandwich materials used in naval ships. It is more convenient to be able to make the measurements directly...

  13. Investigation on Wall Panel Sandwiched With Lightweight Concrete

    Science.gov (United States)

    Lakshmikandhan, K. N.; Harshavardhan, B. S.; Prabakar, J.; Saibabu, S.

    2017-08-01

    The rapid population growth and urbanization have made a massive demand for the shelter and construction materials. Masonry walls are the major component in the housing sector and it has brittle characteristics and exhibit poor performance against the uncertain loads. Further, the structure requires heavier sections for carrying the dead weight of masonry walls. The present investigations are carried out to develop a simple, lightweight and cost effective technology for replacing the existing wall systems. The lightweight concrete is developed for the construction of sandwich wall panel. The EPS (Expanded Polystyrene) beads of 3 mm diameter size are mixed with concrete and developed a lightweight concrete with a density 9 kN/m3. The lightweight sandwich panel is cast with a lightweight concrete inner core and ferrocement outer skins. This lightweight wall panel is tested for in-plane compression loading. A nonlinear finite element analysis with damaged plasticity model is carried out with both material and geometrical nonlinearities. The experimental and analytical results were compared. The finite element study predicted the ultimate load carrying capacity of the sandwich panel with reasonable accuracy. The present study showed that the lightweight concrete is well suitable for the lightweight sandwich wall panels.

  14. Effect of microencapsulated phase change material in sandwich panels

    Energy Technology Data Exchange (ETDEWEB)

    Castellon, Cecilia; Medrano, Marc; Roca, Joan; Cabeza, Luisa F. [GREA Innovacio Concurrent, Edifici CREA, Universitat de Lleida, Pere de Cabrera s/n, 25001 Lleida (Spain); Navarro, Maria E.; Fernandez, Ana I. [Departamento de Ciencias de los Materiales e Ingenieria Metalurgica, Universitat de Barcelona, Marti i Franques 1, 08028 Barcelona (Spain); Lazaro, Ana; Zalba, Belen [Instituto de Investigacion en Ingenieria de Aragon, I3A, Grupo de Ingenieria Termica y Sistemas Energeticos (GITSE), Dpto. Ingenieria Mecanica, Area de Maquinas y Motores Termicos, Universidad de Zaragoza, Campus Politecnico Rio Ebro, Edificio ' ' Agustin de Betancourt,' ' Maria de Luna s/n, 50018 Zaragoza (Spain)

    2010-10-15

    Sandwich panels are a good option as building materials, as they offer excellent characteristics in a modular system. The goal of this study was to demonstrate the feasibility of using the microencapsulated PCM (Micronal BASF) in sandwich panels to increase their thermal inertia and to reduce the energy demand of the final buildings. In this paper, to manufacture the sandwich panel with microencapsulated PCM three different methods were tested. In case 1, the PCM was added mixing the microencapsulated PCM with one of the components of the polyurethane. In the other two cases, the PCM was added either a step before (case 2) or a step after (case 3) to the addition of the polyurethane to the metal sheets. The results show that in case 1 the effect of PCM was overlapped by a possible increase in thermal conductivity, but an increase of thermal inertia was found in case 3. In case 2, different results were obtained due to the poor distribution of the PCM. Some samples showed the effect of the PCM (higher thermal inertia), and other samples results were similar to the conventional sandwich panel. In both cases (2 and 3), it is required to industrialize the process to improve the results. (author)

  15. Damage assessment of compression loaded debond damaged sandwich panels

    DEFF Research Database (Denmark)

    Moslemian, Ramin; Berggreen, Christian; Quispitupa, Amilcar

    2010-01-01

    with an implanted circular face/core debond. Compression tests were conducted on intact sandwich panels and panels with an implanted circular face/core debond with three different types of foam core materials (PVC H130, PVC H250 and PMI 51-IG). The strains and out-of-plane displacements of the debonded region were...

  16. An Assessment of the Speed Reading Ability of Sandwich Students ...

    African Journals Online (AJOL)

    The paper discusses the concept and usefulness of rapid reading. It also reports a study in which the Faculty of Education, University of Lagos, Nigeria Sandwich students formed the subjects. Their pre-training reading speed and comprehension scores were determined through a pre-test, after which they were subjected to ...

  17. Stiff, Strong Splice For A Composite Sandwich Structure

    Science.gov (United States)

    Schmaling, D.

    1991-01-01

    New type of splice for composite sandwich structure reduces peak shear stress in structure. Layers of alternating fiber orientation interposed between thin ears in adhesive joint. Developed for structural joint in spar of helicopter rotor blade, increases precision of control over thickness of adhesive at joint. Joint easy to make, requires no additional pieces, and adds little weight.

  18. Enhanced detection levels in a semi-automated sandwich ...

    African Journals Online (AJOL)

    A peptide nucleic acid (PNA) signal probe was tested as a replacement for a typical DNA oligonucleotidebased signal probe in a semi-automated sandwich hybridisation assay designed to detect the harmful phytoplankton species Alexandrium tamarense. The PNA probe yielded consistently higher fluorescent signal ...

  19. Nonglobal proof of the thin--sandwich conjecture

    International Nuclear Information System (INIS)

    Pereira, C.M.

    1981-01-01

    A gravitational thin--sandwich conjecture was first proposed by Wheeler and coworkers during the period 1962--4. The present paper contains a proof of the nonglobal form of this gravitational thin--sandwich conjecture. The proof (a) applies for arbitrary choices of the spatial metric and its time derivative; and (b) demonstrates the existence on a spacelike three-surface of solutions which satisfy conditions of continuity known to be sufficient to obtain existence and uniqueness of solutions to Einstein's equations off the three-surface and existence and uniqueness of geodesics. Riquier's existence theorem plays an important role in the proof. The relationship of the present results to previous work is discussed. Some global questions associated with the thin--sandwich conjecture are clarified. Some aspects of the relationship of the thin--sandwich conjecture to the problem of the quantization of the gravitational field are noted. Both the vacuum case and the case of a nonviscous fluid are included. The discussion allows for an arbitrary equation of state p = p

  20. Residual Strength of In-plane Loaded Debonded Sandwich Panels

    DEFF Research Database (Denmark)

    Berggreen, Carl Christian; Simonsen, Bo Cerup

    2005-01-01

    This paper presents a FEM based numerical model for prediction of residual strength of damaged sandwich panels. As demonstrated, the model can predict the maximum load carrying capacity of real-life panels with debond damages, where the failure is governed by face-sheet buckling followed by debond...

  1. Interfacial Crack Arrest in Sandwich Panels with Embedded Crack Stoppers Subjected to Fatigue Loading

    DEFF Research Database (Denmark)

    Martakos, G.; Andreasen, J. H.; Berggreen, Christian

    2017-01-01

    A novel crack arresting device has been implemented in sandwich panels and tested using a special rig to apply out-of-plane loading on the sandwich panel face-sheets. Fatigue crack propagation was induced in the face-core interface of the sandwich panels which met the crack arrester. The effect o...

  2. Flexural Behavior of Aluminum Honeycomb Core Sandwich Structure

    Science.gov (United States)

    Matta, Vidyasagar; Kumar, J. Suresh; Venkataraviteja, Duddu; Reddy, Guggulla Bharath Kumar

    2017-05-01

    This project is concerned with the fabrication and flexural testing of aluminium honey comb sandwich structure which is a special case of composite materials that is fabricated by attaching two thin but stiff skins to a light weight but thick core. The core material is normally low density material but its high thickness provide the sandwich composite with high bonding stiffness. Honeycomb core are classified into two types based on the materials and structures. Hexagonal shape has a unique properties i.e has more bonding strength and less formation time based on the cell size and sheet thickness. Sandwich structure exhibit different properties such as high load bearing capacity at low weight and has excellent thermal insulation. By considering the above properties it has tendency to minimize the structural problem. So honey comb sandwich structure is choosed. The core structure has a different applications such as aircraft, ship interiors, construction industries. As there is no proper research on strength characteristics of sandwich structure. So, we use light weight material to desire the strength. There are different parameters involved in this structure i.e cell size, sheet thickness and core height. In this project we considered 3 level of comparison among the 3 different parameters cell size of 4, 6 and 8 mm, sheet thickness of 0.3, 0.5 and 0.7 mm, and core height of 20,25 and 30 mm. In order to reduce the number of experiment we use taguchi design of experiment, and we select the L8 orthogonal array is the best array for this type of situation, which clearly identifies the parameters by independent of material weight to support this we add the minitab software, to identify the main effective plots and regression equation which involves the individual response and corresponding parameters. Aluminium material is used for the fabrication of Honeycomb sandwich structure among the various grades of aluminium we consider the AL6061 which is light weight material

  3. Comparison of radioimmunoassay and ELISA methods for detection of antibodies to chromatin components

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, E; Cheng, N [North Carolina Univ., Chapel Hill (USA). Dept. of Bacteriology and Immunology

    1983-09-16

    A solid phase radioimmunoassay has been compared with an enzyme-linked immunosorbent assay (ELISA) for efficacy in measuring anti-chromatin antibodies. The low backgrounds achieved with the radioimmunoassay method produced a high signal-to-noise ratio and enabled detection of the human test antiserum at a dilution of 1:102,400. By contrast, the ELISA could detect the same antiserum only at a dilution of 1;3200 and above. The radioimmunoassay was consistently more sensitive than the ELSIA for detection of anti-chromatin antibodies in a number of human and mouse sera and ascites fluid containing a monoclonal antibody. Factors affecting sensitivity in both assays are discussed.

  4. Study of antibody immobilization on different magnetic particles utilized for the radioimmunoassay (RIA) and immunoradiometric assay (IRMA) of hormones

    International Nuclear Information System (INIS)

    Ribela, M.T.C.P.; Peroni, C.N.; Bartolini, P.

    1996-01-01

    A study was carried out on antibody immobilization on three different types of magnetic particles: plain magnetite (Institute of Isotopes, Hungary), silanized magnetite (Institute of Atomic Energy, China) and Magnetizable cellulose (SCIPAC, UK). For radioimmunoassay (RIA) applications an efficient 2 nd antibody (AB)-coupled magnetic solid phase, utilizing plain magnetite and a purified anti-rabbit IgG antibody (Trilab, Brazil), was prepared. A consistent bias, detected in comparison with a well known commercial magnetic solid phase kit, was practically eliminated by modifying the coupling and saturation procedure. Concerning two-site IRMA application, an extensive study was carried out on the matching and selection of anti-hTSH antibodies that could be used for capture and detection. Very satisfactory results were obtained with the three types of magnetic particles using different monoclonal and polyclonal antibodies and in particular, two partners anti-hTSH mABs from the National Institute of Health of Thailand. Utilizing also a recombinant hTSH standard preparation, calibrated and distributed by our laboratory (IPEN-CNEN/SP, Brazil), it was possible to obtain a complete set of in-house reagents for hTSH IRMA, prepared and tested under IAEA support. (author). 11 refs, 4 figs, 12 tabs

  5. Epitope mapping of the carcinoembryonic antigen by monoclonal antibodies and establishment of a new improved radioimmunoassay system

    International Nuclear Information System (INIS)

    Kuroki, Masahide; Arakawa, Fumiko; Matsunaga, Akira; Okamoto, Naomi; Takakura, Kyoko; Matsuoka, Yuji; Higuchi, Hiroshi.

    1987-01-01

    A comprehensive mapping of epitopes on the carcinoembryonic antigen (CEA) molecule has been achieved by analyses of the specificities of 146 monoclonal antibodies (MAbs) from more than 300 hybridomas established recently. The reactivities of MAbs were analyzed by radio-immunoassays (RIA) with highly purified preparations of CEA and related antigens including normal fecal antigen-1 (NFA-1), NFA-2 in normal adult feces, nonspecific cross-reacting antigen (NCA) in lung and NCA-2 in meconium. The MAbs could be divided into five groups: group I, 23 clones directed to the NCA-common part of the CEA molecule; group II, 31 clones directed to the normal fecal cross-reacting antigen (NFCA)-common part; group III, 46 clones directed to the NFA-1-common part; group IV, 33 clones reactive with the heterogeneous carbohydrate part; and group V, 13 clones directed to the CEA-distinctive part which seemed to be highly specific for CEA. Mutual inhibitions of CEA binding between MAbs of the individual groups revealed that at least 25 different subgroups can be defined i.e., 4, 7, 8, 4, and 2 subgroups in groups I to V, respectively. The epitopes recognized by the group IV MAbs were found to be sensitive to oxidation with periodate, while the epitopes defined by MAbs of the other groups were resistant to this treatment. A solid-phase sandwich-type RIA system for CEA was established by using 2 MAbs from groups II and III as the CEA catcher and an MAb of group V as the tracer. This assay was shown to exhibit improved cancer-specificity and accuracy in the estimation of serum CEA levels. (author)

  6. The Planar Sandwich and Other 1D Planar Heat Flow Test Problems in ExactPack

    Energy Technology Data Exchange (ETDEWEB)

    Singleton, Jr., Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-24

    This report documents the implementation of several related 1D heat flow problems in the verification package ExactPack [1]. In particular, the planar sandwich class defined in Ref. [2], as well as the classes PlanarSandwichHot, PlanarSandwichHalf, and other generalizations of the planar sandwich problem, are defined and documented here. A rather general treatment of 1D heat flow is presented, whose main results have been implemented in the class Rod1D. All planar sandwich classes are derived from the parent class Rod1D.

  7. Radioimmunoassay of arginine vasopressin (AVP) and clinical application

    International Nuclear Information System (INIS)

    Wagner, H.; Haeberle, M.; Franz, H.E.; Maier, V.

    1977-01-01

    The low circulating levels of vasopressin required an initial extraction procedure. The extraction method itself presented problems with the specificity and the reproducibility of the extracted hormone from serum. The presented paper describes the developement of a radioimmunoassay without an extraction procedure. The AVP was coupled with rabbit-albumin by gluteraldehyde condensation for the immunization of rabbits. Synthetic AVP was iodinated by the method of GREENWOOD and HUNTER (1963) and purified by the addition of Dowex. The antibody cannot differentiate between lysine- and arginine-, ornithine-, glycerine - vasopressin and oxytocin. 1 - 24 ACTH and gastrin did not crosscreact. Normal subjects were found to have 5.7 +- 4.4/uU/ml after a dehydration period of 12 hours. Subjects suffering from psychogenic polydipsia showed normal levels, however, different forms of stress yielded higher levels in normal subjects. In patients suffering from liver cirrhosis the values normalized when ascites was under control. (orig.) [de

  8. Radioimmunoassay for the determination of free and conjugated abscisic acid

    International Nuclear Information System (INIS)

    Weiler, E.W.

    1979-01-01

    The characterization and application of a radioimmunoassay specific for free and conjugated abscisic acid (ABA) is reported, The antibodies produced against a bovine serum albumin-(+-)-ABA conjugate have a high affinity for ABA (Ka= 1.3 x 10 9 l mol -1 ). Trans, trans-ABA and related compounds, such as xanthoxin, phaseic acid, dihydrophaseic acid, vomifoliol or violaxanthin do not interfere with the assay. The detection limit of this method is 0.25 x 10 -12 mol ABA, the measuring range extends to 20 x 10 -12 mol, and average recoveries are 103%. Because of the high specificity of this immunoassay, no extract purification steps are required prior to analysis. Several hundred plants can be analyzed per day in a semi-automatic assay performance. ABA has been detected in all higher plant families examined, but was absent in the blue-green alga, Spirulina platensis, the liverwort Marchantia polymorpha, and two species of fungi. (orig.) [de

  9. Radioimmunoassay techniques and reproductive management of livestock in North Africa

    International Nuclear Information System (INIS)

    Lahlou-Kassi, A.; Lakhdissi, H.

    1984-01-01

    The report summarizes the principal applications of progesterone radioimmunoassay (P 4 -RIA) in Morocco for evaluating and improving fertility in cattle, sheep and camels. In cattle, P 4 -RIA of blood or milk helped to determine the time for onset of sexual functions after parturition and the incidence of silent oestrus. It is especially important to assess the first factor in semi-extensively managed herds, while the second factor occurs mainly in intensively managed herds. P 4 -RIA is an important tool in fertility improvement programmes involving induction and synchronization of oestrus and testing for early pregnancy. In sheep, P 4 -RIA helped to define the optimum age at first mating of ewe lambs and the optimum mating season of the year for adult ewes. In camels, analysis of the profile of plasma progesterone before and after mating suggests that P 4 -RIA could be used for early pregnancy testing. (author)

  10. Production of Anti-triiodothyronine sulfate antibody for radioimmunoassay applications

    International Nuclear Information System (INIS)

    Elbanna, I.M.; Ragab, M.T.

    2000-01-01

    Triiodothyronine sulfate (T3S) may be an obligatory intermediate metabolic of the metabolism of thyroid gland hormones invertebrates in peripheral during the process of deiodination of the inactive form of the thyroid gland hormones, thyroxine(T4), into the active form triiodothyronine (1,2). Construction of a reliable procedure for the estimation of T3S accurately in blood serum will be of great importance for medical, biochemical and physiological investigations. In this work we developed a robust method for the production of anti-triiodothyronine sulfate polyclonal antiserum with good specifications using a derivatized immuno gen and a modified immunization process and a sensitive radioimmunoassay system was designed and developed

  11. An improved radioimmunoassay for urinary Tamm-Horsfall glycoprotein

    International Nuclear Information System (INIS)

    Dawnay, A.B. St. J.; Thornley, C.; Cattell, W.R.

    1982-01-01

    A rapid specific radioimmunoassay has been used to measure Tamm-Horsfall glycoprotein (TH glycoprotein) in urine, and the method described. The apparent concentration increased with increasing dilution of urine in water, reaching a plateau at 1 in 20. This increase was greater the higher the osmolality and TH glycoprotein concentration and the lower the pH of the original sample. The apparent concentration of TH glycoprotein in neat or diluted urine was not affected by freezing or by storage at 4 0 C or room temperature for at least 2 days. A physiological range for the urinary excretion rate was established as 22-56 mg/24h, (considerably higher than the amount present in serum) based on samples from 29 individuals with normal renal function, as defined by their creatinine clearance. There was no significant correlation between serum concentrations of TH glycoprotein and its urinary excretion rate, nor between urinary excretion rate and creatinine clearance. (author)

  12. A simplified radioimmunoassay of adenosine-3':5'-monophosphate

    International Nuclear Information System (INIS)

    Katoh, Yoshiki; Takezawa, Junichi; Suzuki, Morio; Kuninaka, Akira; Yoshino, Hiroshi

    1975-01-01

    Dextran-coated charcoal was proved to be able to separate free adenosine-3':5'monophosphate (cAMP) from antibody-bound cAMP. Only free cAMO was adsorbed on dextran-coated charcoal within 1 min after contacting the charcoal. In a reaction mixture of cAMP and anti-cAMP-plasma, most of antibody-bound cAMP had not been adsorbed 4 min after contacting. The data obtained were found to be almost the same as the data of another experiment using cellulose ester filter separation technique. Thus, dextran-coated charcoal could be employed to simplify the radioimmunoassay of cAMP. (author)

  13. A radioimmunoassay of gastric inhibitory polypeptide in human plasma

    International Nuclear Information System (INIS)

    Sarson, D.L.; Bryant, M.G.; Bloom, S.R.

    1980-01-01

    A sensitive radioimmunoassay for the measurement of human gastric inhibitory polypeptide (GIP), using pure porcine GIP, has been developed. Cross-reactivity of the antiserum with all available mammalian gut peptide preparations was negligible with the exception of glucagon when it was approximately 1%. Two major molecular forms of GIP were detectable in plasma and tissue extracts, one of large molecular size and the other corresponding to the elution coefficient of pure porcine standard. Concentrations of GIP in plasma from 50 normal subjects after overnight fasting were 9+-1.0(S.E.M.) pmol/1 rising to a peak of 34+-2.8 pmol/1 following the ingestion of a small mixed test meal. Ingestion of glucose or fat resulted in a similar rise of plasma GIP, whereas no change was observed after the ingestion of protein. (author)

  14. The measurement of platelet activation by radioimmunoassay in asthma

    International Nuclear Information System (INIS)

    Wu Guoxin; Sun Jian; Li Jianyong; Ruan Changgeng

    1992-02-01

    Radioimmunoassay with specific monoclonal antibody was used to evaluate the platelet activation in 14 cases of acute bronchial asthma. The result showed that the number of molecules of alpha-granule membrane protein (GMP-140) which was exposed on the surface of platelet following secretion significantly increased on the surface of platelet and in plasma, while the number of molecules of glycoprotein (GP) I b and GPIII a did not change significantly; the concentration of thromboxane B 2 in plasma was raised, while the concentration of 6-keto-PGF 1a was within the normal limits; the concentrations of β-thromboglobulin (β-TG) and platelet factor 4(PF 4 ) in plasma increased significantly; the number of platelets decreased. These results strongly confirmed that the degree of platelet activation was enhanced during acute asthmatic attack. The significance of platelet activation in the pathogenesis of asthma should be further investigated

  15. Milk samples collected with filter paper for progesterone radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Jiahua, Zhang; Guoxia, Geng; Huaiyu, Zhang

    1985-09-01

    The cow milk was collected with filter paper treated with ethanol during eastrus-day (0 day) and 22th and 24th day after mating. Then it was dried and stored in room temprature until analysis for progesterone by means of radioimmunoassay. The sensitivity is 13.62 pg/bule (n = 4), the coefficients of variation within a group and between groups are 8.8% (n = 10) and 16.65% (n = 8) respectively, and the recovery is 91.23% (n = 4). The average progesterone level for 22th and 24th day in the pregnant cows (6.28 +- 1.28 ng/ml) was much higher than that in the non-pregnant cow (2.00 +- 1.18 ng/ml), the difference being significant (P < 0.001). The judgement based on progesterone level (5 pregnant and 5 non-pregnant cows) faily agreed with the clinical diagnosis.

  16. Radioimmunoassay for human plasma 8-arginine-vasopressin

    International Nuclear Information System (INIS)

    Conte-Devolx, B.; Rougon-Rapuzzi, G.; Millet, Y.

    1977-01-01

    A radioimmunoassay for human plasma vasopressin (AVP) which permits the estimation of antidiuretic hormone (ADH) level as low as 0.8pg/ml, was developed. The average plasma level of AVP after overnight water restriction was found to be 14.3pg/ml (sd=4.4pg/ml) in normal subjects. They provoked a hypersecretion of ADH by the intravenous injection of 1-2mg of nicotine. In 11 volunteer normal subjects this stimulation by nicotine provoked ADH hypersecretion which reached a maximum between 2nd and 15th minutes after injection. In 3 cases of diabetes insipidus, nicotine injection did not induce ADH hypersecretion: in 1 case of potomania this response was weak; in 2 cases of syndrome of inappropriate ADH secretion, AVP plasma levels were elevated and the response after nicotine stimulation was exaggerated [fr

  17. Development and characterization of a homologous radioimmunoassay for equine prolactin

    International Nuclear Information System (INIS)

    Roser, J.F.; Chang, Y.S.; Papkoff, H.; Li, C.H.

    1984-01-01

    A specific and sensitive homologous radioimmunoassay has been developed for equine prolactin, suitable for measuring prolactin concentrations in serum of horses. The sensitivity of the assay ranged from 0.4 to 0.6 ng/ml and the intra- and inter-assay coefficients of variation averaged 6.9 and 15.4%, respectively, for five doses of hormone. Cross-reactivity with other mammalian and nonmammalian prolactins and growth hormones was less than 20 and 0.3%, respectively. Cross-reactivity with equine growth hormone was less than 0.07%. Equine serum and pituitary extracts showed parallel dilution-response curves with equine prolactin. The percentage recovery of exogenous equine prolactin in serum was 89%. Preliminary analysis of several physiological samples (stallions, pregnant, and nonpregnant mares) yielded values from 0.6 to 12.0 ng/ml

  18. Radioimmunoassay of hair for determining opiate-abuse histories

    International Nuclear Information System (INIS)

    Baumgartner, A.M.; Jones, P.F.; Baumgartner, W.A.; Black, C.T.

    1979-01-01

    Heroin and morphine metabolites can be detected in hair with the use of commerically available radioimmunoassay reagents and with minor sample preparation. Hair samples obtained from morphine-treated mice and heroin users contained nanogram levels of the drug per milligram of hair (single human hair). The results of the hair analyses for all subjects admitting the use of heroin were positive, whereas the results of only 30% of thin-layer chromatographic urinanalyses of these same subjects were positive. In addition, differences in drug concentration for sections of hair near the scalp and near the distal end correlated with the length of time the drug had been used. These results exemplify the potential advantages of the use of hair analysis over urine and serum analyses in terms of accessibility, sample stability, and long-term retention of information

  19. Radioimmunoassay of inactive creatine kinase B protein in human plasma

    Energy Technology Data Exchange (ETDEWEB)

    Burnam, M H; Shell, W E [California Univ., Los Angeles (USA). School of Medicine

    1981-08-27

    The authors describe a rapid, sensitive radioimmunoassay for enzymatically inactive creatine kinase B protein (CK-Bi) in plasma. /sup 125/I-CK-Bi of high specific activity and good stability was prepared by oxidant-based iodination. A 12-minute first antibody incubation was used. Bound and free antigen were separated by a second antibody system. Large excesses of purified CK-MM from human skeletal muscle did not react in the assay. Cross reactivity to CK-MB purified from the plasma of patients with acute myocardial infarction was negligible. The 95th percentile of plasma CK-Bi in 150 adults was 145 ..mu..g equivalents/ml. Within-assay and between-assay precision ranged from 5% to 9% and 6% to 10%, respectively. Evidence is presented indicating that the assay measures inactive creatine kinase B protein, a protein not measured by current assay systems dependent on biological activity.

  20. Provision of radioimmunoassays for reproductive hormones in developing countries

    International Nuclear Information System (INIS)

    Sufi, S.B.; Donaldson, A.; Jeffcoate, S.L.; Goncharov, N.P.

    1986-01-01

    The Special Programme of Research, Development and Research Training in Human Reproduction of the World Health Organization (WHO) has, for the last eight years, distributed sets of matched assay reagents for the radioimmunoassay of hormones to approximately 75 laboratories in 45 countries. The Matched Reagent Programme has enabled these centres to carry out research that would otherwise have been difficult, if not impossible, for them to undertake. Between-centre comparability, as judged by WHO External Quality Assurance Scheme data, has improved and at least five hundred scientific papers have been published as a consequence of the availability of WHO reagents. National and regional reagent programmes and associated schemes are being encouraged. These activities should help to improve the availability of research and diagnostic facilities for patient care in developing countries, which is consistent with the WHO policy of technology transfer. (author)

  1. Engineering of radioimmunoassay (RIA) IP10.1

    International Nuclear Information System (INIS)

    Hari Nurcahyadi

    2010-01-01

    Engineering of Radioimmunoassay (RIA) IP10.1 is an innovative by PRPN - BATAN in 2010. Innovations made to the device IP10.1 RIA is the sample changer system, sample changer system on the device RIA IP10.1 applied 2 linear axis system (X, Z) with AC servo motor. In the RIA IP10.1 also use 5 pieces of the detector, so the enumeration process 50 (Fifty) sample is expected to be faster. Like its predecessor, The whole enumeration, data collection procedures and mechanisms operating within this system is entirely controlled by a PC via an electronic module. Electronics module consists of a high voltage module, amplifier and signal processor module, the module enumerators, low-voltage module, the module driver motor controller and a USB interface. The data acquisition and communication system using a USB port with the computer. (author)

  2. Radioimmunoassay for prostatic acid phosphatase in human serum. Methodologic aspects

    International Nuclear Information System (INIS)

    Pradalier, N.; Canal, P.; Pujol, A.; Fregevu, Y.; Soula, G.

    1982-01-01

    We propose a double antibody radioimmunoassay for human prostatic acid phosphatase (PAP) in serum for diagnosis and management of prostatic adenocarcinoma under treatment. The antigen is purified from human prostatic fluid by a gel-filtration on Sephadex G 100 followed by affinity chromatography on Con A Sepharose. A specific antibody is raised in rabbits and purified by immunoadsorption with a female serum. The described technique offers both radioisotopic sensibility and immunologic specificity. Physiological values determined in the serum of 125 healthy males are below 2 ng/ml. No significative differences are observed with age. The proposed technique also shows significant differences between values evaluated for benign prostatic hyperplasia and prostatic adenocarcinoma [fr

  3. Radioimmunoassay of paralytic shellfish toxins in clams and mussels

    International Nuclear Information System (INIS)

    Yang, G.C.; Imagire, S.J.; Yasaei, P.; Ragelis, E.P.; Park, D.L.; Page, S.W.; Carlson, R.E.; Guire, P.E.

    1987-01-01

    Shellfish contaminated with paralytic shellfish poisons (PSP) compromise human health. The threat of this contamination results in enormous economic losses in the recreational and commercial exploitation of shellfish resources in the affected areas. Most states deal with the PSP problem either by prohibiting the collection of shellfish during certain time periods or by instituting monitoring programs. The only recognized method of analysis for PSP that is currently and routinely used in monitoring programs is the time-of-death mouse bioassay. Several attempts to develop simple and highly specific biochemical assays for the detection and quantitation of the PSP toxins have been reported. More recently, much improved immunoassays have been developed. To evaluate the validity and usefulness of the immunoassay for the determination of PSP toxins, the authors have used extracts of shellfish gathered from Maine and Connecticut to compare the results of the mouse bioassay and HPLC methods with the radioimmunoassay developed previously

  4. Recombinant-derived chicken growth hormone used for radioimmunoassay

    International Nuclear Information System (INIS)

    Proudman, J.A.

    1984-01-01

    The use of recombinant-derived chicken growth hormone (rcGH) in an avian growth hormone (GH) radioimmunoassay (RIA) procedure is described. Antiserum to turkey GH bound 125 I-labeled rcGH, and unlabeled rcGH or turkey GH displaced binding in a dose-related manner. The dose-response curves of sera and pituitary extract from chickens and turkeys were parallel to the rcGH standard curve. Sera from hypophysectomized (hypox) chickens and turkeys produced no dose-response and did not inhibit binding of labeled rcGH. Recovery of rcGH added to hypox sera was quantitative. Modification of the homologous turkey GH RIA protocol of Proudman and Wentworth (1) to use rcGH made possible either an increase in assay sensitivity or a 3-day reduction in incubation time

  5. Development of a radioimmunoassay for triamcinolone acetonide in horse plasma

    International Nuclear Information System (INIS)

    Gylstorff, B.

    1982-01-01

    A radioimmunoassay (RIA) was developed for the detection of triamcinolone acetonide (TAAc) in equine blood plasma. These antibodies exhibited cross reactions of 0,015% with cortisol and of 0,1% with other endogenous glucocorticoids. Four different synthetic corticosteroids interfered in a range of 0,21 to 0,93%. In vitro 86 of TAAc could be recovered. This method proved sufficient reproducibility down to a limit of 131,7 fmol/ml = 57,2 pg/ml. The TAAc RIA is suitable for the detection of a TAAc application particularly during the 1st day p.i. The results may obtain a higher limit of confidence by the simultaneous demonstration of cortisol suppression. By the use of this test more detailed conclusions may be drawn about presence and duration of a pharmacodynamic action originating from the TAAc depot. (orig./TRV) [de

  6. Detection of phencyclidine usage by radioimmunoassay of saliva

    International Nuclear Information System (INIS)

    McCarron, M.M.; Walberg, C.B.; Soares, J.R.; Gross, S.J.; Baselt, R.C.

    1984-01-01

    Paired serum and saliva samples, obtained from 100 emergency department patients suspected of phencyclidine (PCP) intoxication, were analyzed using a specific PCP radioimmunoassay (RIA). Seventy-four of the 100 saliva samples and 75 of the paired serum samples were positive for PCP. The final clinical diagnosis was PCP intoxication in 79 cases. Of these, both serum and saliva tests were positive in 70 cases, only serum was positive in two cases, and both serum and saliva samples were negative in seven cases. The concentration of PCP in the samples did not correlate with the severity of PCP intoxication. In the remaining 21 cases, with no clinical evidence of PCP intoxication, PCP assays were negative in both serum and saliva in 17 cases, three patients had positive saliva and serum tests, and one other patient had a positive PCP saliva assay. Thus, saliva would appear to be as reliable as serum as a specimen for PCP analysis

  7. A selective and simplified radioimmunoassay of 25-hydroxyvitamin D3

    International Nuclear Information System (INIS)

    Hummer, L.; Nilas, L.; Tjellesen, L.; Christiansen, C.

    1984-01-01

    A simple, non-chromatographic and selective assay for determination of 250 HD 3 in serum is described. The serum sample is deproteinated with acetonitrile and the supernatant purified over a small prepacked cartridge, Sep-pak. In the eluate from the cartridge, 250 HD 3 is measured by radioimmunoassay. The selectivity of the assay for 250 HD 3 is improved by adding vitamin D 2 to the antiserum; the assay is thus capable of measuring 250 HD 3 in serum samples containing up to a ratio of 250 HD 2 /250 HD 3 equal to 150. The simplicity, speed and the small amount of sample needed (0.5 ml) make this method suitable for use in a routine clinical laboratory. Because of its selectivity for 250 HD 3 the assay is a necessary prerequisite in the further investigation of metabolic discrimination between vitamins D 2 and D 3 . (author)

  8. Pancreatic elastase in human serum. Determination by radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Geokas, M.C. (Univ. of California, Davis); Brodrick, J.W.; Johnson, J.H.; Largman, C.

    1977-01-10

    This study demonstrates that a serine endopeptidase of pancreatic origin (elastase 2) circulates in human blood. A specific and highly sensitive radioimmunoassay has been developed for pancreatic elastase 2 in human serum. The inactivation of elastase 2 employed as radioiodinated tracer with an active site-specific reagent (phenylmethanesulfonyl fluoride) was necessary to prevent its binding by serum ..cap alpha../sub 1/-antitrypsin and ..cap alpha../sub 2/-macroglobulin while maintaining its immunoreactivity. The assay is based upon competition of standard human pancreatic elastase 2 with /sup 125/I-labeled phenylmethanesulfonyl elastase 2 for specific antibody binding sites, after which a second antibody precipitation step is used to separate bound from free /sup 125/I-labeled phenylmethanesulfonyl elastase 2. The minimum detectable concentration of elastase 2 was 0.9 ng/ml. The average normal fasting serum level determined was 71 ng/ml, approximately 80-fold greater than the minimum detectable amount.

  9. Production of biological reagents for radioimmunoassay second antibody

    International Nuclear Information System (INIS)

    Borghi, V.C.; Silva, S.R. da; Bellini, M.H.; Lin, L.H.

    1992-02-01

    The experimental production of second antibody to be used in hormonal assays, in which the first antibody is raised in rabbits, is described. Four sheep were immunized with the rabbit immunoglobulin prepared at IPEN-CNEN laboratory. Their antisera were evaluated by the human thyrotropin radioimmunoassay employing materials provided by the National Hormone and Pituitary Program (USA), in comparison with a reference antiserum of known quality, produced in goat by the Radioassay Systems Laboratories - RSL (USA). From the fourth booster injection the animals developed antiserum with titer similar to that exhibited by the commercial product, even presenting higher values. These antisera are now being examinated for the optimal conditions of precipitation before be packed for future use and distribution. (author)

  10. Radioimmunoassay of plasma myoglobin concentrations in normal persons

    Energy Technology Data Exchange (ETDEWEB)

    Milanov, S.; Milkov, V. (Meditsinska Akademiya, Sofia (Bulgaria). Nauchen Inst. po Rentgenologiya i Radiobiologiya)

    1982-01-01

    Plasma myoglobin concentrations by radioimmunoassay in 53 normal persons (29 women and 24 men) with ages ranging from 19 to 76 years. The average values for myoglobin concentrations in the plasma of 29 women, aged 19 to 76 years, are 4a.09 +- 4.51 ng/ml, while in 24 healthy men, aged 20 to 74 years, they are 54.39 +-4.68 ng/ml. The obtained results for the plasma myoglobin level in men are higher than the ones recorded in women at statistical significance p<0.05. In the group under study the plasma myoglobin values disclose also age-related differences, although lacking statistical significance (p>0.10).

  11. Iodine-125--digoxin radioimmunoassay: comparison of commercial kits

    International Nuclear Information System (INIS)

    Battaglia, D.J.; Cianci, M.L.

    1976-01-01

    Iodine-125-digoxin radioimmunoassay kits available from Abbott Diagnostics (AD), Dade Division (D), Schwarz/Mann (SM), and Clinical Assays (CA) were evaluated with respect to assay quality. The kit accuracies did not differ significantly at 2.0 ng/ml and the interassay coefficients of variation ranged from 9 percent (AD) to 21.4 percent (CA). The accuracy for all kits above 4 ng/ml is questionable, and since serum-dilution values correlated well with undiluted serum values, the dilution method of dose quantitation is preferable for levels above 4 ng/ml. Although all the kits were adequate for evaluating digoxin at the 2 ng/ml level, the Abbott kit seems to be of slightly better quality

  12. Radioimmunoassay data processing program for IBM PC computers

    International Nuclear Information System (INIS)

    1989-06-01

    The Medical Applications Section of the International Atomic Energy Agency (IAEA) has previously developed several programs for use on the Hewlett-Packard HP-41C programmable calculator to facilitate better quality control in radioimmunoassay through improved data processing. The program described in this document is designed for off-line analysis using an IBM PC (or compatible) for counting data from standards and unknown specimens (i.e. for analysis of counting data previously recorded by a counter), together with internal quality control (IQC) data both within and between batch. The greater computing power of the IBM PC has enabled the imprecision profile and IQC control curves which were unavailable on the HP-41C version. It is intended that the program would make available good data processing capability to laboratories having limited financial resources and serious problems of quality control. 3 refs

  13. Radioimmunoassay of inactive creatine kinase B protein in human plasma

    International Nuclear Information System (INIS)

    Burnam, M.H.; Shell, W.E.

    1981-01-01

    The authors describe a rapid, sensitive radioimmunoassay for enzymatically inactive creatine kinase B protein (CK-Bi) in plasma. 125 I-CK-Bi of high specific activity and good stability was prepared by oxidant-based iodination. A 12-minute first antibody incubation was used. Bound and free antigen were separated by a second antibody system. Large excesses of purified CK-MM from human skeletal muscle did not react in the assay. Cross reactivity to CK-MB purified from the plasma of patients with acute myocardial infarction was negligible. The 95th percentile of plasma CK-Bi in 150 adults was 145 μg equivalents/ml. Within-assay and between-assay precision ranged from 5% to 9% and 6% to 10%, respectively. Evidence is presented indicating that the assay measures inactive creatine kinase B protein, a protein not measured by current assay systems dependent on biological activity. (Auth.)

  14. Production of antisera for radioimmunoassay of human proinsulin: preliminary studies

    International Nuclear Information System (INIS)

    Nascimento, M. do; Borghi, V.C.; Bellini, M.H.; Wajchenberg, B.L.

    1990-01-01

    In attempt to the production of anti proinsulin antisera for the radioimmunoassay, five guinea pigs received 50 μg of biosynthetic human proinsulin (Eli Lilly and Company, US) injected subcutaneously. Booster injections were administered at 3 weeks intervals and blood was taken 14 days after the injection. Just after the tenth week, three guinea pigs developed antisera with titers of 1:15.000, 1:1.500 and 1:300 and one of them presented titer lower than 1:300. The evaluation of the specificity of those three antisera showed cross-reactivity only with insulin, which antibodies were not sufficiently sensitive for the assay of endogenous proinsulin from healthy subjects, being only suitable for the measurement of circulating proinsulin in patients with hyper proinsulinemia. Alternative schedules of immunization in order to obtain more sensitive antisera are discussed. (author)

  15. Radioimmunoassay for phencyclidine: application to kinetic analysis in the rat

    International Nuclear Information System (INIS)

    Ward, D.P.; Trevor, A.J.

    1980-01-01

    We report the development of a radioimmunoassay for phencyclidine (PCP) that is simple, rapid and sensitive to 0.5 ng/ml. Antibodies were raised in rabbits against the hapten, N-succinyl-3-aminophencyclidine. These antibodies proved to be very specific for PCP and exhibited less than 4% cross reactivity with the drug's two major metabolites. The assay was used for kinetic analysis of PCP in the rat following subcutaneous injection of 5 mg/kg of the drug. Serum and brain tissues were analyzed for PCP and the respective half lives were calculated to be 36 and 29 min for the α phase and 130 and 121 min for the β phase. The accuracy of the method was verified by concomitant assay of a number of kinetic samples by gas chromatography employing a nitrogen-phosphorus detector

  16. New, advantageous approach to the direct radioimmunoassay of cortisol

    International Nuclear Information System (INIS)

    Tilden, R.L.

    1977-01-01

    Radioimmunoassay of serum cortisol is simplified by a unique solution to the problem of eliminating competition between cortisol-binding globulin and cortisol immunoglobulin. Increasing incubation temperature tends to release cortisol from its carrier protein while favoring the immunoglobulin reaction. We applied this methodology, using reagents supplied as a commercial kit. Serum, 5 μl, is diluted with 125 I-containing tris(hydroxymethyl)aminomethane buffer and incubated at 45 0 C for 1 h, then aspirated. All standards are constituted in steroid-deprived serum. The clinical validity of the method is supported by comparisons with conventional methods during months of use under routine laboratory conditions. The simplified method also offers improved performance characteristics and, as described, is fully instrumented. The significance of this use of thermodynamic properties is discussed in terms of more general applicability

  17. Radioimmunoassay for human plasma 8-arginine-vasopressin

    Energy Technology Data Exchange (ETDEWEB)

    Conte-Devolx, B [Hopital de la Conception, 13 - Marseille (France); Rougon-Rapuzzi, G [Centre National de la Recherche Scientifique, 13 - Marseille (France); Millet, Y [Aix-Marseille-2 Univ., 13 - Marseille (France)

    1977-01-01

    A radioimmunoassay for human plasma vasopressin (AVP) which permits the estimation of antidiuretic hormone (ADH) level as low as 0.8pg/ml, was developed. The average plasma level of AVP after overnight water restriction was found to be 14.3pg/ml (sd=4.4pg/ml) in normal subjects. They provoked a hypersecretion of ADH by the intravenous injection of 1-2mg of nicotine. In 11 volunteer normal subjects this stimulation by nicotine provoked ADH hypersecretion which reached a maximum between 2nd and 15th minutes after injection. In 3 cases of diabetes insipidus, nicotine injection did not induce ADH hypersecretion: in 1 case of potomania this response was weak; in 2 cases of syndrome of inappropriate ADH secretion, AVP plasma levels were elevated and the response after nicotine stimulation was exaggerated.

  18. Antibodies to lactalbumin interfere with its radioimmunoassay in human plasma

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, U; Laurence, D J.R. [Royal Marsden Hospital, London (UK); Ormerod, M G [Institute of Cancer Research, Sutton (UK). Surrey Branch

    1978-01-01

    Two radioimmunoassays for human lactalbumin have been established using a rabbit antiserum. One assay uses a second antibody to separate bound from free label; the other uses polyethylene glycol to precipitate gamma globulin non-specifically. It is confirmed that about half the normal human population have a substance in their blood which inhibits the binding of lactalbumin to the rabbit antibody. Comparison of the two assays has demonstrated that this material is not lactalbumin but a naturally occurring antibody. It is shown that it is in the IgG fraction of human plasma and is probably a cross-reacting antibody to bovine lactalbumin. None out of fifteen males and fourteen out of fifty eight non-pregnant, non-lacatating females had low levels of lactalbumin in their blood (0.6-2.0 ng/ml). The assay could not detect a statistically significant difference between normal women and those with either benign breast disease or metastatic mammary carcinoma.

  19. Radioimmunoassay of parathyroid hormone (parathyrin) in monkey and man

    International Nuclear Information System (INIS)

    Hargis, G.K.; Williams, G.A.; Reynolds, W.A.; Kawahara, W.; Jackson, B.; Bowser, E.N.; Pitkin, R.M.

    1977-01-01

    A radioimmunoassay for rhesus monkey and human innumoreactive parathyrin was developed in which a selected anti-bovine parathyrin antiserum, radioiodinated purified bovine parathyrin tracer, and human parathyroid tissue-culture media standards were used. The resulting data indicate that the method is sensitive, specific, accurate and reproducible; it is valid for both the rhesus monkey and the human; the serum immunoreactive parathyrin concentration of the monkey is essentially the same as that in man; monkey immunoreactive parathyrin responds to changes in serum calcium concentration similarly to that in man; and the rhesus monkey is therefore a suitable species in which to study parathyroid physiology, from which conclusions can be applied to the human

  20. The development of radioimmunoassay kit for rat albumin

    International Nuclear Information System (INIS)

    Yuan Zhigang; Han Shiquan; Liu Yibing; Xu Wenge

    2006-01-01

    The Anti-rat albumin serum is prepared by immunized the sheep with rat albumin. A radioimmunoassay method is established for rat albumin. The measurement range of the assay is 1-50 mg/L, sensitivity of the assay is 0.12 mg/L, recovery rate is 97.8%- 108.4%. Intra- and inter-assay variation coefficients are <4.0% and <8.2% respectively. The correlation coefficients between measured and expected values are more than 0.990 after serial dilution of the urine samples with high concentrations of rat albumin. The kit for rat albumin might provide a convenience in exploitation of renal drugs and experimental in- jury of the kidney. (authors)

  1. Radioimmunoassays for serotonin and 5-hydroxyindole acetic acid

    International Nuclear Information System (INIS)

    Delaage, M.A.; Puizillout, J.J.

    1981-01-01

    Radioimmunoassays for serotonin and 5-hydroxyindole acetic acid were developed. High titer antibodies, having a well-defined high specificity, have been raised by coupling the side-chain of both molecules to human serum albumin. Serotonin is first converted into N-hemisuccinate, and then treated like 5-HIAA, namely, conjugated with HSA for the immunogen. Synthesis of 125 I iodinated analogues was performed by coupling 5-HIAA or N-succinyl serotonin to glycyltyrosine, without any contact between both molecules and the oxidizing reagents. Chemical conversions of biological samples (by succinylation for 5-HT and amidation for 5-HIAA) were carried out. This critical step makes the antigen molecules resemble the immunogen more closely, thus allowing an appreciable gain in specificity and sensitivity. These assays allow the rapid determination of 5-HT and 5-HIAA in small amounts of tissue, blood, cerebral spinal fluid or perfusate without any purification, with a sensitivity threshold of 50 pg

  2. Gastrin radioimmunoassay. Description and application of a novel method

    International Nuclear Information System (INIS)

    Nemeth, J.; Jakab, B.; Schweibert, I.; Szolcsanyi, J.; Oroszi, G.; Szilvassy, Z.

    2002-01-01

    Development and application of a novel gastrin radioimmunoassay (RIA) are described. 125 I-labeling of non-sulphated human gastrin-17 (nshG-17) was performed by the iodogen method and the mono-iodinated hormone, as RIA tracer, was separated by reversed-phase high performance liquid chromatography (HPLC). Serum gastrin levels were measured in response to intravenous application of isoproterenol, a non-selective beta and phenylephrine, a selective alpha-1 receptor agonist using a newly developed method specific for the C-terminal part of the hormone in rats. Isoproterenol at clinically relevant doses elicited a significant increase in serum gastrin concentration in a dose-dependent fashion, whereas phenylephrine was without effect. (author)

  3. Studies on radioimmunoassay of peptide hormone using polyethyleneglycol. I. Insulin

    Energy Technology Data Exchange (ETDEWEB)

    Kihara, A; Kikuchi, A; Yaegashi, T; Ohhara, H [Sapporo Medical Coll. (Japan)

    1975-06-01

    Radioimmunoassay (RIA) of insulin using polyethyleneglycol (PEG) was examined for measurement conditions such as the concentration, reaction time, temperature, and amount of serum to be added in order to allow uniform separations of free insulin and bound insulin. The standard curve of the present method was in good agreement with that of the two antibody method, and the two methods showed a highly significant correlation (r=0.98, p<0.001). The reproducibility showed only the fluctuations ranging from 0.9 to 4.9%, and the recovery rate was between 70 and 100%. Since the insulin RIA by PEG is convenient and economical and yields more stable results than those obtained by the two antibody method, it is possible to use it for RIA of other peptide hormones such as glucagon.

  4. Importance of radioimmunoassay of insulin secretion disorder as atherogenic factor

    Energy Technology Data Exchange (ETDEWEB)

    Knyazev, Yu A; Bespalova, V A; Vakhrusheva, L L; Kirbasova, N P; Severtseva, V V

    1984-11-01

    Using a radioimmunoassay a C-peptide levei was revealed in children, pregnant and lying-in women as well as in patients with insulin-dependent diabetes mellitus. After breakfast and insulin administration wich curative purposes the IRI concentration in children increased whereas the C-peptide level changed insignificantly. Changes of the insulin secretion were more noticeable in severe diabetes mejlitus with vascular complications and in disease decompensation. The atherogenic nature of the lipid metaboiism (an increase in the cholesterol, triglyceride and ..beta..-lipoprotein levels), changes in the liver and tendency to vascular involvement are results of insulin effect inadequacy. Such metabolic derangements in pregnant women create unfavorable conditions for the development of fetus and may lead to early atherogenic processes.

  5. Measurement of plasma canine C peptide by radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Besch, W; Woltanski, K P; Fischer, U; Kohnert, K D; Ziegler, M

    1985-12-01

    A sensitive radioimmunoassay for canine C peptide (CCP) was established using synthetic CCP, a specific antiserum, and rabbit anti-guinea pig serum. Radioiodination was performed according to a modified chloramine T method. Tracer preparations have been used for 6 weeks after iodination. The standard curve ranges from 0.028 to 3.0 nmol/l. The intra-assay coefficient of variation (CV) was 3-5% and the inter-assay CV was 6-9% in the optimal range between 0.3 and 0.8 nmol/l. The average recovery of CCP added to plasma samples was 100.6% (n = 9). Canine insulin, porcine proinsulin, bovine proinsulin, and human C peptide exhibited no cross-reactivity. The mean fasting plasma CCP concentration was 0.089 +- 0.021 nmol/l in normal dogs and -0.005 +- 0.007 nmol/l (mean +- SEM) in diabetic dogs, respectively.

  6. High molecular somatostatin, an interfering factor in radioimmunoassay

    International Nuclear Information System (INIS)

    Diel, F.; Schneider, E.; Baumann, H.

    1977-01-01

    Cyclic Tyr 1 -somatostatin (Tyr 1 -SRIF) is radioiodinated by the lactoperoxidase method. Purification is achieved by Sephadex G-25 adsorption chromatography. Specific anti-SRIF serum (FA1) has been raised in rabbits. A dose response curve is obtained in the range of 5 - 5,000 pg per tube using an antiserum dilution of 1:2,000. There is little cross-reaction with linear somatostatin and none with ocytocin, (lys-, arg-) vasopressin, valinomycin, polymyxin, insulin, glucagon, human growth hormone (hGH), and thyrotropin-releasing hormone (TRH). For recovery tests, extraction procedures are necessary. Thin-layer chromatography (TLC) and polyacrylamide-disc-electrophoresis (Disc-PAGE) are performed to identify the presumed high molecular 125 I-Tyr 1 -SRIF associate. This high molecular associate may represent an interfering factor in the radioimmunoassay for cyclic SRIF. (orig./AJ) [de

  7. Effect of radioimmunoassay procedures on therapeutic drug monitoring

    International Nuclear Information System (INIS)

    Kampa, I.S.

    1985-01-01

    Methods for the measurement of therapeutic drugs have covered every aspect of analysis from extraction to derivatization. In general, published methods were modified to shorten drug extractions and overall analysis time. The use of different standards, as well as the frequent omission of internal standards, often produced large and clinically unacceptable analytical variations. As a result, physicians would adjust drug dosages according to the physiological response to a standard dose. The introduction of radioimmunoassay techniques for the quantitation of therapeutic drugs have made a significant impact on the clinical chemistry laboratory. The similarities of the various assay methods and the technologists' familiarity with the assay protocols have produced clinically relevant results. Clinical laboratories are now able to frequently analyze a large number of samples with acceptable accuracy and precision. The esoteric test once performed infrequently is today a routine analytical assay often performed STAT. Therapeutic drug monitoring has become a major activity in many clinical laboratories

  8. Radioimmunoassay for pregnancy-associated plasma protein A

    International Nuclear Information System (INIS)

    Sinosich, M.J.; Teisner, B.; Folkerson, J.; Saunders, D.M.; Grudzinskas, J.G.

    1982-01-01

    A specific and highly sensitive radioimmunoassay for determination of pregnancy-associated plasma protein A in human serum is described. The minimum detection limit for this protein was 2.9 μg/L. The within- and between-assay coefficients of variation were 4.0 and 4.5%, respectively. The circulating protein was detected within 32 days of conception in eight normal pregnancies and within 21 days in a twin pregnancy. Circulating concentrations in the mother at term were consistently higher (10-fold) than in matched amniotic fluid; none was detected in the umbilical circulation. This protein was also detected in the circulation of patients with hydatidiform mole. This assay will permit investigations into the clinical evaluation of measurements of the protein during early pregnancy and trophoblastic disease

  9. Performance of various mathematical methods for calculation of radioimmunoassay results

    International Nuclear Information System (INIS)

    Sandel, P.; Vogt, W.

    1977-01-01

    Interpolation and regression methods are available for computer aided determination of radioimmunological end results. We compared the performance of eight algorithms (weighted and unweighted linear logit-log regression, quadratic logit-log regression, Rodbards logistic model in the weighted and unweighted form, smoothing spline interpolation with a large and small smoothing factor and polygonal interpolation) on the basis of three radioimmunoassays with different reference curve characteristics (digoxin, estriol, human chorionic somatomammotropin = HCS). Great store was set by the accuracy of the approximation at the intermediate points on the curve, ie. those points that lie midway between two standard concentrations. These concentrations were obtained by weighing and inserted as unknown samples. In the case of digoxin and estriol the polygonal interpolation provided the best results while the weighted logit-log regression proved superior in the case of HCS. (orig.) [de

  10. Radioimmunoassays for cyclic AMP cross-react with phosphodiesterase inhibitors and buffer components

    NARCIS (Netherlands)

    Sinha, B; Semmler, J; Haen, E; Moeller, J; Endres, S

    We addressed the issue of cross-reactivity of several commonly used phosphodiesterase inhibitors with radioimmunoassays for cyclic AMP, after we had observed a considerably high cross-reactivity with a noncommercial antibody. Theophylline, pentoxifylline, penthydroxifylline (BL 194), albifylline

  11. Development of a radioimmunoassay for pig pancreatic kallikrein and its application in physiological studies

    International Nuclear Information System (INIS)

    Fink, E.; Guettel, C.; Seifert, J.

    1978-01-01

    A RIA for pig pancreatic kallikrein has been developed. Purified kallikrein was labelled with 125 I. The use of radioimmunoassays in investigating the intestinal absorption of pig pancreas kallikrein is dealt with. (VJ) [de

  12. Quick insulin radioimmunoassay and its utilization for intra operative localization of insulinoma

    International Nuclear Information System (INIS)

    Ursich, M.J.M.; Fukui, R.T.; Aguiar Pupo, A. de; Machado, M.C.C.

    1988-01-01

    A quick insuLin radioimmunoassay performed in 90 minutes is described and the results are compared with those obtained with the conventional method. The realibility of the new procedure is pointed. (M.A.C.) [pt

  13. Antibodies to cytoskeletal proteins as evidenced by immunofluorescence microscopy and radioimmunoassay

    International Nuclear Information System (INIS)

    Zugehoer, M.; Struy, H.; Morenz, J.

    1987-01-01

    In patients suffering from chronic hepatitis, collagenosis and infectious mononucleosis, resp., as well as in blood donors antibodies against cytoskeletal antigens such as actin, myosin, actinin, desmin, keratin, and tubulin were determined by radioimmunoassay

  14. Radioimmunoassay for chicken avidin. Comparison with a (/sup 14/C)biotin-binding method

    Energy Technology Data Exchange (ETDEWEB)

    Kulomaa, M S; Elo, H A; Tuohimaa, P J [Tampere Univ. of Tech. (Finland)

    1978-11-01

    A double-antibody solid-phase radioimmunoassay for chicken avidin is reported. Avidin was labelled with /sup 125/I by the chloramine-T method. The bound and free avidin were separated with a second antibody bound to a solid matrix. In the logit-log scale the standard curve was linear from 1-2 to 100-200ng of avidin/ml. Cross-reaction of ovalbumin was less than 0.015%. Saturation of biotin-binding sites of avidin with an excess of biotin decreased radioimmunoassay values by about 15%. Recovery studies indicated that avidin can be assayed from all chicken tissues studied with radioimmunoassay, whereas the (/sup 14/C)biotin/bentonite method gave poor recoveries for avidin in the liver and kidney. Radioimmunoassay and the (/sup 14/C)biotin/bentonite method gave similar concentrations for oviduct avidin.

  15. Comparison of tritiated and iodinated tracers in the radioimmunoassay of progesterone in cow milk

    Energy Technology Data Exchange (ETDEWEB)

    Allen, R M; Redshaw, M R [Hoechst Pharmaceuticals Research Ltd., Milton Keynes (UK); Holdsworth, R [Milk Marketing Board, Worcester (UK). Veterinary Research Unit

    1980-01-01

    Progesterone levels in the milk of cows were determined by two radioimmunoassay methods. Excellent correlation (r = 0.95) was found between the method using an iodinated radioligand and that using a conventional tritiated tracer.

  16. Diagnosis of prostate cancer using a radioimmunoassay for prostatic acid phosphatase in serum

    International Nuclear Information System (INIS)

    Lea, O.A.; Hoeisaeter, P.Aa.

    1981-01-01

    The paper describes the development and evaluation of a specific radioimmunoassay for the determination of prostatic acid phosphatase in serum as a useful aid in the detection of prostatic cancer. (Auth.)

  17. Antibodies to cytoskeletal proteins as evidenced by immunofluorescence microscopy and radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Zugehoer, M; Struy, H; Morenz, J

    1987-01-01

    In patients suffering from chronic hepatitis, collagenosis and infectious mononucleosis, resp., as well as in blood donors antibodies against cytoskeletal antigens such as actin, myosin, actinin, desmin, keratin, and tubulin were determined by radioimmunoassay.

  18. A different approach to the radioimmunoassay of thyrotropin releasing hormone

    International Nuclear Information System (INIS)

    Visser, T.J.; Klootwijk, W.; Docter, R.; Hennemann, G.

    1977-01-01

    Thyrotropin releasing hormone (TRH) was linked to hemocyanin by means of a dinitrophenylene moiety. TRH (pGlu-His-Pro-NH 2 ) was made to react with a large excess of 1,5-difluoro-2,4-dinitrobenzene to yield Nsup(im)-[5-fluoro-2,4-dinitrophenyl]TRH. After removal of excess reagent the derivative was coupled to hemocyanin with a minimum of side-reactions. From two rabbits out of four immunized with this material valuable antisera were obtained, which were used in the radioimmunoassay of the hypothalamic hormone at a final dilution of 1:7,500 and 1:15,000, respectively. The properties, especially with regard to specificity, of these antisera were studied and compared with another antiserum, which was obtained using a conjugate having TRH linked to thyroglobulin via a p-azophenyl-acetyl moiety. Despite the difference between the derivatives, i.e. the nature and the point of attachment of the side chains, the specificities of the assays were very similar. Deamidation of TRH, deletion of either one of the terminal residues, hydrolysis of the lactam of the pyroglutamyl residue, and replacing Pro-NH 2 by Pro-Gly-NH 2 or by an octapeptide chain yield peptides with strongly diminished cross-reactivities. However, Nsup(im)-benzyl-TRH and pGlu-Phe-Pro-NH 2 were 5-10 times as active as TRH probably due to a closer physico-chemical similarity to the arrangement of the haptens in the conjugates. This suggests that the sensitivity of the radioimmunoassay may be increased markedly by conversion of TRH into the Nsup(im)-dinitrophenyl derivative and by using a related compound for radioiodination. (orig.) [de

  19. New Solid Phases for Estimation of Hormones by Radioimmunoassay Technique

    International Nuclear Information System (INIS)

    Sheha, R.R.; Ayoub, H.S.M.; Shafik, M.

    2013-01-01

    The efforts in this study were initiated to develop and validate new solid phases for estimation of hormones by radioimmunoassay (RIA). The study argued the successful application of different hydroxy apatites (HAP) as new solid phases for estimation of Alpha fetoprotein (AFP), Thyroid Stimulating hormone (TSH) and Luteinizing hormone (LH) in human serum. Hydroxy apatites have different alkali earth elements were successfully prepared by a well-controlled co-precipitation method with stoichiometric ratio value 1.67. The synthesized barium and calcium hydroxy apatites were characterized using XRD and Ftir and data clarified the preparation of pure structures of both BaHAP and CaHAP with no evidence on presence of other additional phases. The prepared solid phases were applied in various radioimmunoassay systems for separation of bound and free antigens of AFP, TSH and LH hormones. The preparation of radiolabeled tracer for these antigens was carried out using chloramine-T as oxidizing agent. The influence of different parameters on the activation and coupling of the used apatite particles with the polyclonal antibodies was systematically investigated and the optimum conditions were determined. The assay was reproducible, specific and sensitive enough for regular estimation of the studied hormones. The intra-and inter-assay variation were satisfactory and also the recovery and dilution tests indicated an accurate calibration. The reliability of these apatite particles had been validated by comparing the results that obtained by using commercial kits. The results finally authenticates that hydroxyapatite particles would have a great potential to address the emerging challenge of accurate quantitation in laboratory medical application

  20. Radioimmunoassay of cholecystokinin in human tissue and plasma

    International Nuclear Information System (INIS)

    Jansen, J.B.M.J.; Lamers, C.B.H.W.

    1983-01-01

    A highly sensitive radioimmunoassay for cholecystokinin (CCK) without any cross-reactivity with gastrin is described. The antibody was raised in a rabbit by immunisation with 30% CCK and bound to all COOH-terminal CCK-peptides containing at least 14 amino acid residues. The affinity constant of the antibody was 59.4 x 10 10 l/mol. CCK 33 conjugated to [ 125 I]hydroxyphenylpropionic acid-succinimide ester was used as label. The binding between label and antibody was inhibited by 50% (ID 50 ) at a concentration of 2.8 pmol/l cholecystokinin 33. The detection limit of the assay was between 0.5 and 1.0 pmol/l plasma. Concentrations of CCK in aqueous acid extracts of human upper small intestine were 36.5 +- 9.8 pmol/g and of human cerebral cortex 28.2 +- 2.5 pmol/g tissue. Plasma samples were extracted in 96% ethanol prior to assay. No advantage was obtained by adding aprotinin to the tubes. When frozen at -20 0 C plasma CCK was stable for at least 6 months. Basal plasma CCK concentrations in 30 normal subjects were very low, 0.9 +- 0.1 pmol/l, range 0.5 to 3.1 pmol/l. Intraduodenal administration of fat induced significant increases in plasma CCK from 1.1 +- 0.1 to 8.2 +- 1.3 pmol/l (p = 0.01). Infusion of exogenous CCK, resulting in plasma CCK levels slightly lower than those measured during administration of fat, induced pancreatic enzyme secretion and gallbladder contraction. The reliability of this radioimmunoassay for measurements of CCK in human plasma was extensively evaluated. (Auth.)

  1. Radioimmunoassay for luteinizing hormone releasing hormone in plasma

    International Nuclear Information System (INIS)

    Saito, Shiro; Musa, Kimitaka; Oshima, Ichiyo; Yamamoto, Suzuyo; Funato, Toyohiko

    1975-01-01

    A sensitive and specific double antibody radioimmunoassay has been developed capable of measuring LH-RH in extracted human plasma. Thyrotropin releasing hormone, lysine vasopressin and most of LH-RH analogues did not appear to affect the assay. Hypothalamic extract and some of the LH-RH analogues produced displacement curves which were parallel to the curve obtained with the synthetic LH-RH. Sensitivity of the radioimmunoassay was about 3 pg per assay tube. The coefficient of variation of intraassays was 6.4%, while that of interassays was 9.6%. Exogenous LH-RH could be quantitatively extracted by acidic ethanol when varying amounts of synthetic LH-RH were added to the plasma. Immunoreactivity of LH-RH was preserved in plasma for 2 hrs in the cold but was gradually reduced thereafter. The plasma levels of LH-RH were 20 pg/ml or less in normal adults and not detectable in children. Aged males over 60 yr and postmenopausal women showed a tendency to have higher levels of plasma LH-RH. The plasma LH-RH level was significantly higher in midcycle than in the follicular or luteal stages. The disappearance rate of LH-RH from the circulation after intravenous injection could be represented as half-times of 4-6 min. Between 0.2-0.4% of the injected dose was excreted into urine within 1 hr. These results indicate that the determination of LH-RH might be a useful tool for elucidating hypothalamic-pituitary-gonad interactions. (auth.)

  2. Inventions leading to the development of the diagnostic test kit industry--from the modern pregnancy test to the sandwich assays.

    Science.gov (United States)

    Wide, Leif

    2005-01-01

    The universities are encouraged by the government nowadays to stimulate innovations and also to provide the proper machinery for assisting the protection and commercialisation of innovations. A better understanding of the innovation process may help to create an atmosphere suitable for inventions at the university. Examples can be taken from successful innovations previously made at the university. During the 1960's I made a series of inventions, which ultimately led to the development of the diagnostic test kit industry. The first, which I made as an undergraduate, was a simple and reliable test kit for diagnosis of pregnancy. This was followed by the solid phase radioimmunoassay and a solid phase assay for vitamin B12; next, the dual specific non-competitive sandwich assay and the in-vitro test for diagnosis of allergy, called RAST (Radioallergosorbent test). Organon in Holland with the pregnancy test kit, and Pharmacia in Sweden with test kits for radioimmunoassay, became pioneers among the diagnostic test kit industries. Pharmacia Diagnostics later became one of the leading diagnostic test kit companies in the world and has continued to be so in the field of allergy diagnosis. Each one of these inventions started with a few unique observations leading to a technical development. The pregnancy test as well as the allergy test emerged from the development of assay methods with unique qualities with the subsequent search for appropriate applications. The foreseeing of a commercial value on a future market was a very important step. This was followed by the search for a suitable industry interested to exploit the invention with its new business opportunity i.e. apply for a patent, produce and market the products, which in my case consisted of the necessary reagents and equipments for particular diagnostic tests. Finally, an agreement had to be settled between the entrepreneur and the inventors. This report describes these inventions and particularly discusses some

  3. Comparative studies on the determination of alphafetoprotein by enzyme immunoassay and by radioimmunoassay

    International Nuclear Information System (INIS)

    Haller, G.; Linneke, P.; Voss, P.; Jeske, W.

    1987-01-01

    Alphafetoprotein (AFP) was determined in serum of pregnant women in the tenth till sixteenth week of pregnancy by means of two enzyme immunoassays (Enzymun-Test AFP, Boehringer Mannheim, FRG and AFP EIA 'Dessau' 1000, Research Institute for Vaccine Dessau, GDR) and a radioimmunoassay (Radioimmunoassay Kit, AFP-PR, CIS, France). Parallel determinations in sera of 438 patients, who had come to surveillance for the first consultation were estimated. A comparison between the methods showed a good correlation. (author)

  4. Monoclonal antibodies against pregnancy-specific β1-glycoprotein (SP1) in immunohistochemistry and radioimmunoassay

    International Nuclear Information System (INIS)

    Wahlstroem, T.; Heikinheimo, M.

    1983-01-01

    Monoclonal mouse antibodies against pregnancy-specific beta-1-glycoprotein (SP 1 ) have been studied for their suitability in immunoperoxidase staining and radioimmunoassay methodologies. These antibodies were useful in staining normal placentas, hydatidiform moles, invasive moles and choriocarcinomas. They showed good specificity, with minimal background staining, and will thus be superior to conventional polyclonal antisera in immunohistochemistry. However, the presently tested monoclonal anti-SP 1 antibodies were found not to be suitable for radioimmunoassay. (Auth.)

  5. Radioimmunoassay in assessment of function of the hypothalamo-neurohypophyseal system in patients with hypothalamic syndromes

    International Nuclear Information System (INIS)

    Slavnov, V.N.; Markov, V.V.; Rudichenko, V.M.

    1991-01-01

    Radioimmunoassay of vasopressin was conducted before and after drug tests and exercise for assessment of function of the hypothalamo-neurohypophyseal system in 165 patients with hypothalamic syndromes. It was shown that radioimmunoassay gave the adequate information for assessment of function of hypothalamo-neurohypophyseal system on the base of study of basal and stimulated vasopressin secretion. It permits to make an individual choice of the most effective drug for therapy of the hypothalamic syndrome of neuroendocrine-metabolic type

  6. Quantitation of chordin in developing Huso huso embryos and larvae by radioimmunoassay

    International Nuclear Information System (INIS)

    Preobrazhensky, A.A.; Glinka, A.V.

    1985-01-01

    Chordin is a protein discovered in the notochord cells of the representatives of Acipenseridae; giant sturgeon, stellate sturgeon and sterlet. Some characteristics of the purified chordin preparation which justify its use in radioimmunoassay are described. A sensitive competitive-binding double-antibody radioimmunoassay for chordin is described by which its content in the extracts from giant sturgeon embryos and larvae has been measured. It is shown that chordin biosynthesis started in the embryos from stage 32. (Auth.)

  7. Radioimmunoassay for detection of VP1 specific neutralizing antibodies of foot and mouse disease virus

    International Nuclear Information System (INIS)

    Patzer, E.J.; Jackson, M.L.; Moore, D.M.

    1985-01-01

    A solid-phase radioimmunoassay was developed for the detection of antibodies against a specific region of the VP1 protein of the A24 and O1 serotypes of foot and mouth disease virus. The antibody titers from the radioimmunoassay showed a positive correlation with neutralizing antibody titers determined by a mouse protection assay. The specificity of the assay resides in the peptide used as antigen. The assay is rapid, reproducible and does not require the use of whole virions. (orig.)

  8. Vasoactive intestinal polypeptide (VIP) tissue distribution in the rat as measured by radioimmunoassay and by radioreceptorassay

    International Nuclear Information System (INIS)

    Besson, J.; Dupont, C.; Laburthe, M.; Bataille, D.; Rosselin, G.

    1977-01-01

    A new radioimmunoassay which allows the measurement of the rat vasoactive intestinal polypeptide, was performed. VIP is present in the whole digestive tract of rat, mainly between the duodenum and the colon. 1.5% of the total VIP is present in brain. The VIP-like immunoreactivity appears to correspond to biologically active molecule since a radioreceptorassay using liver plasma membranes as the target tissue, gives the same results as the radioimmunoassay [fr

  9. Serum gonadotropins levels in childhood. Critical comparison between immunoradiometric assays and radioimmunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Hertogh, R. De; Vankrieken, L. (Physiology of Human Reproduction Research Unit, University of Louvain, School of Medicine, Brussels (Belgium)); Wolter, R.; Vliet, G. Van (Hopital Universitaire des Enfants, Reine Fabiola, Free University of Brussels (Belgium))

    1989-01-01

    The complex changes in serum LH and FSH levels from infancy to adulthood are diversely evaluated by radioimmunoassays or bioassays. The relative lack of sensitivity and specificity of radioimmunoassay, using polyclonal antibodies, could possibly be overcome by new immunoradiometric assays, using specific antibodies to LH and FSH. Significant differences were indeed observed between radioimmunoassays and immunoradiometric assays. During the prepubertal period, LH levels, measured by the immunoradiometric assays, were below the sensitivity of the method in the majority of the samples. LH levels were, however, well detectable when measured with radioimmunoassay, showing the heterogeneity of circulating LH structures. At the onset of puberty, LH levels increased at least 3 to 4 times in both sexes, when measured with immunoradiometric assays, whereas their increase was only 20 to 60% with the radioimmunoassays. FSH levels remained well detectable in the prepubertal period whether measured by immunoradiometric or radioimmunoassays. At pubertal onset, FSH increase in both sexes was more important in the immunoradiometric assays. The results obtained with immunoradiometric assays give a better insight into the quantitative and qualitative function of the gonadotropes during childhood. The almost complete absence of LH during the prepubertal period and the steep increase at the onset of puberty better reflects the reported data obtained with bioassays. The persistance of significant levels of FSH in the prepubertal ages, and the lesser increase at the onset of puberty, when compared with LH, illustrates that the individual regulation of LH and FSH secretion vary over time and is influenced by developmental factors. (author).

  10. Theoretical prediction on corrugated sandwich panels under bending loads

    Science.gov (United States)

    Shu, Chengfu; Hou, Shujuan

    2018-05-01

    In this paper, an aluminum corrugated sandwich panel with triangular core under bending loads was investigated. Firstly, the equivalent material parameters of the triangular corrugated core layer, which could be considered as an orthotropic panel, were obtained by using Castigliano's theorem and equivalent homogeneous model. Secondly, contributions of the corrugated core layer and two face panels were both considered to compute the equivalent material parameters of the whole structure through the classical lamination theory, and these equivalent material parameters were compared with finite element analysis solutions. Then, based on the Mindlin orthotropic plate theory, this study obtain the closed-form solutions of the displacement for a corrugated sandwich panel under bending loads in specified boundary conditions, and parameters study and comparison by the finite element method were executed simultaneously.

  11. Applications of thin-film sandwich crystallization platforms

    Energy Technology Data Exchange (ETDEWEB)

    Axford, Danny, E-mail: danny.axford@diamond.ac.uk; Aller, Pierre; Sanchez-Weatherby, Juan; Sandy, James [Diamond Light Source, Harwell Oxford, Didcot OX11 0DE (United Kingdom)

    2016-03-24

    Crystallization via sandwiches of thin polymer films is presented and discussed. Examples are shown of protein crystallization in, and data collection from, solutions sandwiched between thin polymer films using vapour-diffusion and batch methods. The crystallization platform is optimal for both visualization and in situ data collection, with the need for traditional harvesting being eliminated. In wells constructed from the thinnest plastic and with a minimum of aqueous liquid, flash-cooling to 100 K is possible without significant ice formation and without any degradation in crystal quality. The approach is simple; it utilizes low-cost consumables but yields high-quality data with minimal sample intervention and, with the very low levels of background X-ray scatter that are observed, is optimal for microcrystals.

  12. Buckling analysis of SMA bonded sandwich structure – using FEM

    Science.gov (United States)

    Katariya, Pankaj V.; Das, Arijit; Panda, Subrata K.

    2018-03-01

    Thermal buckling strength of smart sandwich composite structure (bonded with shape memory alloy; SMA) examined numerically via a higher-order finite element model in association with marching technique. The excess geometrical distortion of the structure under the elevated environment modeled through Green’s strain function whereas the material nonlinearity counted with the help of marching method. The system responses are computed numerically by solving the generalized eigenvalue equations via a customized MATLAB code. The comprehensive behaviour of the current finite element solutions (minimum buckling load parameter) is established by solving the adequate number of numerical examples including the given input parameter. The current numerical model is extended further to check the influence of various structural parameter of the sandwich panel on the buckling temperature including the SMA effect and reported in details.

  13. Fracture Characterization of Sandwich Face/Core Interfaces

    DEFF Research Database (Denmark)

    Manca, Marcello

    of load transfer between the faces and the core layer is lost, the debonds are considered as primary damage initiators. Under fatigue loading the debonds may evolve into cracks that cause a reduction in structural performance and consequent failure. At present most structural design is based on “life-time...... of sandwich structures is defects that are introduced in the manufacturing process. It is inevitable that areas of the face sheets will not fully adhere to the core resulting in defects known as “debonds”. Debonds can also be induced in-service due to e.g. localised impact loading or overloading. As the means...... such result it is important to devise new experimental and analytical techniques to establish the multi-mode fracture characteristics of sandwich plate structures and accordingly develop methods to inhibit defect propagation. This thesis deals with characterization of fracture between face and core...

  14. Enhanced Performance of Sandwich Structures by Improved Damage Tolerance

    DEFF Research Database (Denmark)

    Martakos, Georgios

    are embedded in both sandwich beam and panel specimens. The experimental observations form the basis for evaluating the efficiency of the proposed crack stopping inserts. For the experiments, Digital Image Correlation (DIC) was used to characterize the measure the local strain fields and overall deformation...... behaviour around the new crack stopper elements. In support for the experimental investigations, a Finite Element (FE) analysis based methodology, including fracture mechanics analysis and the so-called ‘cycle jump’ technique, was developed to predict the progression of damage in sandwich specimens...... concentrations in the foam core material on the back side of the peel stopper. By use of the developed numerical fracture mechanics based modelling tools, both fatigue crack growth and crack arrest in the specimens were simulated. It was shown that the strains responsible for crack re-initiation can...

  15. Outcome of the TURP-TUVP sandwich procedure for minimally ...

    African Journals Online (AJOL)

    shanker

    TURP–TUVP sandwich procedure for the surgical treatment of BPH larger than 40cc in volume. 23 used was 21.5 L (SD = 4.9).The mean post-operative hospital stay was 3.5 days (range 3- 4 days). Overall,. 11 (19%) patients had blood transfusion, there was no incidence of TUR syndrome and one mortality was recorded ...

  16. Fluid Structure Interaction Effect on Sandwich Composite Structures

    Science.gov (United States)

    2011-09-01

    far back as ancient Egyptian times in the use of straw and bricks, or more recently in the last century with the use of steel rebar in concrete ...construction of sandwich composites; however, this particular material was selected for its uniform pattern and translucent qualities after it is wetted out...excellent fire retardant and corrosion resistant qualities making it a natural selection for shipboard applications. The same translucent qualities

  17. Sandwich-panels based on penopolisocyanurate and mineral wool

    OpenAIRE

    Burtzeva M.; Mednikova E.

    2017-01-01

    Sandwich panel is a self-supporting structure consisting of two steel zinc-coated profiles with a layer of heat retainer. It is used as roofing and walling material. Widely is used in industrial construction, shopping centres, sports complexes, chilling and freezing chambers, storage buildings and quickly erectable housing. The classical basis of heat-insulating layer (core panel) products is used mineral wool insulation materials. This material is resistant to deformation, non-flammable,...

  18. Sandwich-structured hollow fiber membranes for osmotic power generation

    KAUST Repository

    Fu, Feng Jiang; Zhang, Sui; Chung, Neal Tai-Shung

    2015-01-01

    In this work, a novel sandwich-structured hollow fiber membrane has been developed via a specially designed spinneret and optimized spinning conditions. With this specially designed spinneret, the outer layer, which is the most crucial part of the sandwich-structured membrane, is maintained the same as the traditional dual-layer membrane. The inner substrate layer is separated into two layers: (1) an ultra-thin middle layer comprising a high molecular weight polyvinylpyrrolidone (PVP) additive to enhance integration with the outer polybenzimidazole (PBI) selective layer, and (2) an inner-layer to provide strong mechanical strength for the membrane. Experimental results show that a high water permeability and good mechanical strength could be achieved without the expensive post treatment process to remove PVP which was necessary for the dual-layer pressure retarded osmosis (PRO) membranes. By optimizing the composition, the membrane shows a maximum power density of 6.23W/m2 at a hydraulic pressure of 22.0bar when 1M NaCl and 10mM NaCl are used as the draw and feed solutions, respectively. To our best knowledge, this is the best phase inversion hollow fiber membrane with an outer selective PBI layer for osmotic power generation. In addition, this is the first work that shows how to fabricate sandwich-structured hollow fiber membranes for various applications. © 2015 Elsevier B.V.

  19. Generation of Elliptically Polarized Terahertz Waves from Antiferromagnetic Sandwiched Structure.

    Science.gov (United States)

    Zhou, Sheng; Zhang, Qiang; Fu, Shu-Fang; Wang, Xuan-Zhang; Song, Yu-Ling; Wang, Xiang-Guang; Qu, Xiu-Rong

    2018-04-01

    The generation of elliptically polarized electromagnetic wave of an antiferromagnetic (AF)/dielectric sandwiched structure in the terahertz range is studied. The frequency and external magnetic field can change the AF optical response, resulting in the generation of elliptical polarization. An especially useful geometry with high levels of the generation of elliptical polarization is found in the case where an incident electromagnetic wave perpendicularly illuminates the sandwiched structure, the AF anisotropy axis is vertical to the wave-vector and the external magnetic field is pointed along the wave-vector. In numerical calculations, the AF layer is FeF2 and the dielectric layers are ZnF2. Although the effect originates from the AF layer, it can be also influenced by the sandwiched structure. We found that the ZnF2/FeF2/ZnF2 structure possesses optimal rotation of the principal axis and ellipticity, which can reach up to about thrice that of a single FeF2 layer.

  20. Sandwiched Rényi divergence satisfies data processing inequality

    International Nuclear Information System (INIS)

    Beigi, Salman

    2013-01-01

    Sandwiched (quantum) α-Rényi divergence has been recently defined in the independent works of Wilde et al. [“Strong converse for the classical capacity of entanglement-breaking channels,” preprint http://arxiv.org/abs/arXiv:1306.1586 (2013)] and Müller-Lennert et al. [“On quantum Rényi entropies: a new definition, some properties and several conjectures,” preprint http://arxiv.org/abs/arXiv:1306.3142v1 (2013)]. This new quantum divergence has already found applications in quantum information theory. Here we further investigate properties of this new quantum divergence. In particular, we show that sandwiched α-Rényi divergence satisfies the data processing inequality for all values of α > 1. Moreover we prove that α-Holevo information, a variant of Holevo information defined in terms of sandwiched α-Rényi divergence, is super-additive. Our results are based on Hölder's inequality, the Riesz-Thorin theorem and ideas from the theory of complex interpolation. We also employ Sion's minimax theorem

  1. Sandwich-structured hollow fiber membranes for osmotic power generation

    KAUST Repository

    Fu, Feng Jiang

    2015-11-01

    In this work, a novel sandwich-structured hollow fiber membrane has been developed via a specially designed spinneret and optimized spinning conditions. With this specially designed spinneret, the outer layer, which is the most crucial part of the sandwich-structured membrane, is maintained the same as the traditional dual-layer membrane. The inner substrate layer is separated into two layers: (1) an ultra-thin middle layer comprising a high molecular weight polyvinylpyrrolidone (PVP) additive to enhance integration with the outer polybenzimidazole (PBI) selective layer, and (2) an inner-layer to provide strong mechanical strength for the membrane. Experimental results show that a high water permeability and good mechanical strength could be achieved without the expensive post treatment process to remove PVP which was necessary for the dual-layer pressure retarded osmosis (PRO) membranes. By optimizing the composition, the membrane shows a maximum power density of 6.23W/m2 at a hydraulic pressure of 22.0bar when 1M NaCl and 10mM NaCl are used as the draw and feed solutions, respectively. To our best knowledge, this is the best phase inversion hollow fiber membrane with an outer selective PBI layer for osmotic power generation. In addition, this is the first work that shows how to fabricate sandwich-structured hollow fiber membranes for various applications. © 2015 Elsevier B.V.

  2. Impact properties of aluminium - glass fiber reinforced plastics sandwich panels

    Directory of Open Access Journals (Sweden)

    Mathivanan Periasamy

    2012-06-01

    Full Text Available Aluminium - glass fiber reinforced plastics (GFRP sandwich panels are hybrid laminates consisting of GFRP bonded with thin aluminum sheets on either side. Such sandwich materials are increasingly used in airplane and automobile structures. Laminates with varying aluminium thickness fractions, fiber volume fractions and orientation in the layers of GFRP were fabricated by hand lay up method and evaluated for their impact performance by conducting drop weight tests under low velocity impacts. The impact energy required for initiating a crack in the outer aluminium layer as well as the energy required for perforation was recorded. The impact load-time history was also recorded to understand the failure behavior. The damage depth and the damage area were measured to evaluate the impact resistance. Optical photography and scanning electron micrographs were taken to visualize the crack and the damage zone. The bidirectional cross-ply hybrid laminate (CPHL has been found to exhibit better impact performance and damage resistance than the unidirectional hybrid laminate (UDHL. Increase in aluminium thickness fraction (Al tf and fiber volume fraction (Vf resulted in an increase in the impact energy required for cracking and perforation. On an overall basis, the sandwich panels exhibited better impact performance than the monolithic aluminium.

  3. Sandwich Structured Composites for Aeronautics: Methods of Manufacturing Affecting Some Mechanical Properties

    Directory of Open Access Journals (Sweden)

    Aneta Krzyżak

    2016-01-01

    Full Text Available Sandwich panels are composites which consist of two thin laminate outer skins and lightweight (e.g., honeycomb thick core structure. Owing to the core structure, such composites are distinguished by stiffness. Despite the thickness of the core, sandwich composites are light and have a relatively high flexural strength. These composites have a spatial structure, which affects good thermal insulator properties. Sandwich panels are used in aeronautics, road vehicles, ships, and civil engineering. The mechanical properties of these composites are directly dependent on the properties of sandwich components and method of manufacturing. The paper presents some aspects of technology and its influence on mechanical properties of sandwich structure polymer composites. The sandwiches described in the paper were made by three different methods: hand lay-up, press method, and autoclave use. The samples of sandwiches were tested for failure caused by impact load. Sandwiches prepared in the same way were used for structural analysis of adhesive layer between panels and core. The results of research showed that the method of manufacturing, more precisely the pressure while forming sandwich panels, influences some mechanical properties of sandwich structured polymer composites such as flexural strength, impact strength, and compressive strength.

  4. Evaluation of a Single-Beam Sonar System to Map Seagrass at Two Sites in Northern Puget Sound, Washington

    Science.gov (United States)

    Stevens, Andrew W.; Lacy, Jessica R.; Finlayson, David P.; Gelfenbaum, Guy

    2008-01-01

    Seagrass at two sites in northern Puget Sound, Possession Point and nearby Browns Bay, was mapped using both a single-beam sonar and underwater video camera. The acoustic and underwater video data were compared to evaluate the accuracy of acoustic estimates of seagrass cover. The accuracy of the acoustic method was calculated for three classifications of seagrass observed in underwater video: bare (no seagrass), patchy seagrass, and continuous seagrass. Acoustic and underwater video methods agreed in 92 percent and 74 percent of observations made in bare and continuous areas, respectively. However, in patchy seagrass, the agreement between acoustic and underwater video was poor (43 percent). The poor agreement between the two methods in areas with patchy seagrass is likely because the two instruments were not precisely colocated. The distribution of seagrass at the two sites differed both in overall percent vegetated and in the distribution of percent cover versus depth. On the basis of acoustic data, seagrass inhabited 0.29 km2 (19 percent of total area) at Possession Point and 0.043 km2 (5 percent of total area) at the Browns Bay study site. The depth distribution at the two sites was markedly different. Whereas the majority of seagrass at Possession Point occurred between -0.5 and -1.5 m MLLW, most seagrass at Browns Bay occurred at a greater depth, between -2.25 and -3.5 m MLLW. Further investigation of the anthropogenic and natural factors causing these differences in distribution is needed.

  5. Quantitative pancreatic β cell MRI using manganese-enhanced Look-Locker imaging and two-site water exchange analysis.

    Science.gov (United States)

    Antkowiak, Patrick F; Vandsburger, Moriel H; Epstein, Frederick H

    2012-06-01

    Pancreatic β-cell imaging would be useful in monitoring the progression of and therapies for diabetes. The purpose of this study was to develop and evaluate quantitative β-cell MRI using manganese (Mn(2+)) labeling of β cells, T1 mapping, and a two-site water exchange model. Normal, pharmacologically-treated, and severely diabetic mice underwent injection of MnCl(2). Pancreatic water proton T1 relaxation was measured using Look-Locker MRI, and two-site water exchange analysis was used to estimate model parameters including the intracellular water proton relaxation rate constant (R1(ic)) and the intracellular fraction as indicators of β-cell function and mass, respectively. Logarithmic plots of T1 relaxation revealed two distinct proton pools relaxing with different T1s, and the two-site water exchange model fit the measured T1 relaxation data better than a monoexponential model. The intracellular R1(ic) time course revealed the kinetics of β-cell Mn(2+) labeling. Pharmacological treatments with nifedipine, tolbutamide, and diazoxide altered R1(ic), indicating that beta cell function was a determinant of Mn(2+) uptake. Intracellular fraction was significantly higher in mice with normal β cell mass than in diabetic mice (14.9% vs. 14.4%, P exchange analysis of T1 relaxation of the Mn(2+)-enhanced pancreas is a promising method for quantifying β cell volume fraction and function. Copyright © 2011 Wiley-Liss, Inc.

  6. ITO-TiN-ITO Sandwiches for Near-Infrared Plasmonic Materials.

    Science.gov (United States)

    Chen, Chaonan; Wang, Zhewei; Wu, Ke; Chong, Haining; Xu, Zemin; Ye, Hui

    2018-05-02

    Indium tin oxide (ITO)-based sandwich structures with the insertion of ultrathin (ITO layers show TiN-thickness-dependent properties, which lead to moderate and tunable effective permittivities for the sandwiches. The surface plasmon polaritons (SPP) of the ITO-TiN-ITO sandwich at the telecommunication window (1480-1570 nm) are activated by prism coupling using Kretschmann configuration. Compared with pure ITO films or sandwiches with metal insertion, the reflectivity dip for sandwiches with TiN is relatively deeper and wider, indicating the enhanced coupling ability in plasmonic materials for telecommunications. The SPP spatial profile, penetration depth, and degree of confinement, as well as the quality factors, demonstrate the applicability of such sandwiches for NIR plasmonic materials in various devices.

  7. Optimization of AFP-radioimmunoassay using Antibody Capture Technique

    International Nuclear Information System (INIS)

    Moustafa, K.A.

    2003-01-01

    Alpha-fetoprotein (AFP) is a substance produced by the unborn baby. When the neural tube is not properly formed large amounts of AFP pass into the amniotic fluid and reach the mother's blood. By measuring AFP in the mother's blood and amniotic fluid, it is possible to tell whether or not there is a chance that the unborn baby has a neural tube defect. AFP also used as a tumor marker for hepatocellular carcinoma. There are many different techniques for measuring AFP in blood, but the most accurate one is the immunoassay technique. The immunoassays can be classified on the basis of methodology into three classes; (1) the antibody capture assays, (2) the antigen capture assay, (3)the two-antibody sandwich assays. In this present study, the antibody capture assay in which the antigen is attached to a solid support, and labeled antibody is allowed to bind, will be optimized

  8. Sound insulation of composite cylindrical shells: a comparison between a laminated and a sandwich cylinder

    OpenAIRE

    Yuan, Chongxin; Roozen, Bert; Bergsma, Otto; Beukers, Adriaan

    2012-01-01

    The fuselages of aircraft are modeled as a cylinder in this paper, and the sound insulations of a sandwich cylinder and a laminated cylinder are studied both experimentally and numerically. The cylinders are excited by an acoustic pressure and a mechanical force respectively. Results show that under acoustic excitation, the sandwich cylinder and the laminated one have a similar sound insulation below 3000 Hz, but the sandwich cylinder has a much larger sound insulation at higher frequencies. ...

  9. Blast-Resistant Improvement of Sandwich Armor Structure with Aluminum Foam Composite

    OpenAIRE

    Yang, Shu; Qi, Chang

    2013-01-01

    Sandwich armor structures with aluminum foam can be utilized to protect a military vehicle from harmful blast load such as a landmine explosion. In this paper, a system-level dynamic finite element model is developed to simulate the blast event and to evaluate the blast-resistant performance of the sandwich armor structure. It is found that a sandwich armor structure with only aluminum foam is capable of mitigating crew injuries under a moderate blast load. However, a severe blast load causes...

  10. Radioimmunoassay of antidiuretic hormone. Application to rats and to man

    International Nuclear Information System (INIS)

    Fressinaud-Masdefeix, Philippe.

    1976-06-01

    The general principles of antidiuretic hormone secretion are known from kidney function explorations and the use of biological methods. Radioimmunoassay of the hormone should contribute towards a better understanding of this secretion in the fields of both physiology and pathology. After a review on antidiuretic hormone and the methods used so far for its investigation, part two of this work concentrates on the development of our own radioimmunological system applied to this hormone. The system is specific, though interference in the measurement from metabolite(s) of the hormone cannot be absolutely ruled out; reproducible, as witnessed by the 'inter-test' variation coefficient of 8%; and sensitive, since the hormone is easily measured in the urine, when secretion is slowed down. In spite of its sensitivity however the hormone determination in the plasma is not possible for a small sample volume because of the difficulty of obtaining high-affinity specific antibodies. To our knowledge only one plasma ADH determination is in common use to date. Part three is devoted to the application of this technique in rats and man, and the results obtained [fr

  11. Radioimmunoassay in the diagnosis of atypical form of thyrotoxicosis

    Energy Technology Data Exchange (ETDEWEB)

    Livshits, G.Ya.

    1984-11-01

    Fifty-six patients with ''unmotivated'' disorder of the cardiac rhythm were examined. A combined radionuclide study including a study of iodoabsorptive function with a standard technique, thyroid visualization and determination of the thyroxin, triiodothyronine level in the blood serum with the radioimmunoassay using standard diagnostic kits, was conducted, Latent thyroid hyperfunction was revealed in 24 patients (42.8%). Study of iodoabsorptive function revealed pathological changes in 8 patients only, whereas raaioimmunoassay revealed a significant elevation of the peripheral thyroid hormone level as compared to that of the control group in 24 patients. The conclusion is that patients with ''unmotivated'' disorder of the cardiac rhythm often suffer from latent thyrotoxicosis which is the main etiological factor and trigger mechanism of arrhythmias. In such a situation they are the only clinical symptom of thyrotoxicosis that makes it possible to regard this form of disease as monosymptomatic. The early detection of the cause of cardiac rhythm disorder and the prescription of pathogenetic thyrostatic therapy resulted in the return of the cardiac cycle rate to normal in all the patients with sinus tachycardia and prevented relapses of the paroxysmal forms of rhythm disorder.

  12. An Interlaboratory study of lipid effects on steroid radioimmunoassay

    International Nuclear Information System (INIS)

    Bolelli, G.F.; Franceschetti, F.; Mimmi, P.; Malvano, R.; Pilo, A.; Zucchelli; Rota, G.

    1986-01-01

    The lipid effects on the performances of routine steroid radioimmunoassay (RIA) have been assessed using the scheme of the CNR interlaboratory quality control program. Cortisol, estradiol, progesterone and testosterone assays have been considered. In the study, ca 80 laboratories were supplied with two sets of control plasma samples with different triglyceride contents (pool N, ca 120 mg/dl; pool L, ca 310 mg/dl), each corresponding to three steroid levels (level 0: charcoaldeprived samples; levels 1 and 2: the same added with increasing steroid amounts). A comparison of the neat results obtained by partecipants for both levels 1 and 2 of N and P panels - after subtraction of the concentrations estimated for level 0 - gave a direct information on lipid effects (triglycerides being assumed as an index of lipemia). In no case the abnormality high triglyceride content proved effective in practical terms, though significant differences were observed for testosterone and progesterone (ca 10% underestimation in pool L) and for estradiol (ca 10% overestimation in pool L)

  13. Determination of antithrombin III by radioimmunoassay and its clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Chan, V; Chan, T K; Wong, V; Tso, S G; Todd, D [Queen Mary Hospital, Hong Kong

    1979-04-01

    A radioimmunoassay (RIA) has been developed for the determination of antithrombin III (AT III) in man. The detection limit was 25 ..mu..g/dl. At III-RIA level and biological activity (anti-Xa) was significantly correlated (r = 0.737, P < 0.0001). Plasma levels in 36 healthy males (mean +- SD, 19.9 +- 2.5 mg/dl) and 21 healthy females (19.1 +- 2.4 mg/dl) were similiar. Serial AT III measurements in normal menstruating females showed lower levels during midcycle and higher concentrations during menstruation. In carcinomas, the AT III levels were lower than normal, particularly in hepatocellular carcinoma. In cirrhosis of liver, the levels were markedly decreased and in some patients were below that found in congenital AT III deficiency. Patients with deep vein thrombosis and patients with heart valve replacement had lower levels than normal, while patients with cerebral vascular occlusion had normal levels. The possible use of AT III as a diagnostic tool of post-operative deep vein thrombosis was demonstrated in one patient after hysterectomy. The increased sensitivity, specificity and precision of this type of assay offer distinct advantages over existing methods of AT III estimation.

  14. The radioimmunoassay of serum alpha-fetoprotein levels

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y H; Choi, K A; Ahn, K S; Suh, W H; Lee, M J [Korea University College of Medicine, Seoul (Korea, Republic of)

    1982-06-15

    Alpha-fetoprotein (AFP) was first described in the human fetus in 1956 and became a marker protein of primary liver cancer in adults. Serum AFP levels were measured by radioimmunoassay in 212 patients with a variety of malignant and nonmalignant diseases to determine the incidence of leveis elevated above 40 ng/ml. The results obtained are as follows: In 44 cases of total 212 patients, abnormal AFP levels above 40 ng/ml in serum were measured; 24 of 31 patients with primary hepatocellular carcinoma and primary hepatocellular carcinoma with liver cirrhosis (77.4%), 7 of 51 patients with only liver cirrhosis (13.7%), 4 of 10 patients with metastatic liver cancer (40.0%), 4 of 15 patients with chronic hepatitis (26.7%), 2 of 23 patients with acute hepatitis (8.7%), and each one patient with 6 pancreatic carcinoma and 9 cholangiocarcinoma had elevated serum AFP levels. One pregnant woman with gestation 35 weeks had elevated level, but within normal limit during pregnancy.

  15. The radioimmunoassay of serum alpha-fetoprotein levels

    International Nuclear Information System (INIS)

    Kim, Y. H.; Choi, K. A.; Ahn, K. S.; Suh, W. H.; Lee, M. J.

    1982-01-01

    Alpha-fetoprotein (AFP) was first described in the human fetus in 1956 and became a marker protein of primary liver cancer in adults. Serum AFP levels were measured by radioimmunoassay in 212 patients with a variety of malignant and nonmalignant diseases to determine the incidence of leveis elevated above 40 ng/ml. The results obtained are as follows: In 44 cases of total 212 patients, abnormal AFP levels above 40 ng/ml in serum were measured; 24 of 31 patients with primary hepatocellular carcinoma and primary hepatocellular carcinoma with liver cirrhosis (77.4%), 7 of 51 patients with only liver cirrhosis (13.7%), 4 of 10 patients with metastatic liver cancer (40.0%), 4 of 15 patients with chronic hepatitis (26.7%), 2 of 23 patients with acute hepatitis (8.7%), and each one patient with 6 pancreatic carcinoma and 9 cholangiocarcinoma had elevated serum AFP levels. One pregnant woman with gestation 35 weeks had elevated level, but within normal limit during pregnancy

  16. Radioimmunoassay of tissue steroids in adenocarcinoma of the prostate

    International Nuclear Information System (INIS)

    Belis, J.A.; Tarry, W.F.

    1981-01-01

    Tissue steroid levels in 48 needle-biopsy samples of adenocarcinoma of the prostate were quantified by radioimmunoassay (RIA). Tissue levels of dihydrotestosterone (DHT), estradiol-17β, and estrone were correlated with tumor stage, histologic grade, and patient response to endocrine therapy. All patients with well-differentiated carcinoma of the prostate had tissue DHT content greater than 2.0 ng/g while 35% of patients with moderately differentiated or poorly differentiated tumors had tissue DHT content less than 2.0 ng/g. DHT content appeared to be unrelated to tumor stage. Estradiol and estrone content correlated well with tumor grade but not with tumor stage. DHT levels were measured in 17 patients with symptomatic Stage D 2 carcinoma of the prostate. Thirteen patients with DHT content greater than 2.0 ng/g initially had an objective and/or subjective response to endocrine therapy. Four patients with tissue DHT levels below 2.0 ng/g had no response to hormonal therapy. Quantification of tissue DHT content by RIA is a promising method for predicting initial response to hormonal therapy in adenocarcinoma of the prostate

  17. Solid phase radioimmunoassays for human C-reactive protein

    International Nuclear Information System (INIS)

    Shine, B.; Beer, F.C. de; Pepys, M.B.

    1981-01-01

    Two new, rapid and sensitive radioimmunoassays for human C-reactive protein (CRP) have been established using antiserum coupled to magnetizable cellulose particles, which facilitate phase separation. A single antibody method, using solid phase anti-CRP, provides a sensitivity of 50 μg/l with a 1-h incubation time and intra- and inter-assay coefficients of variation of 10%. A double antibody method, using fluid phase rabbit anti-CRP serum and solid phase sheep anti-rabbit IgG serum, provides a sensitivity of 3 μg/l with an overnight incubation and intra- and inter-assay coefficients of variation of 10%. Among 468 sera from normal adult volunteer blood donors the median CRP concentration was 800 μg/l, interquartile range 340-1700 μg/l and range 70-29,000 μg/l. Ninety percent of samples contained less than 3 mg/l and 99% less than 10 mg/l. Low levels (14-650 μg/l) of CRP were detected both in amniotic fluids and in cerebrospinal fluids. (Auth.)

  18. Multiple steroid radioimmunoassays and automation. Versatile techniques for reproductive endocrinology

    International Nuclear Information System (INIS)

    Vihko, R.; Hammond, G.L.; Pakarinen, A.; Viinikka, L.

    1978-01-01

    The combination of the efficient steroid-separating properties of a lipophilic Sephadex derivative Lipidex-5000sup(TM) and the use of antibodies with carefully selected specificity allows the quantitative determination of pregnenolone, progesterone, 17α-hydroxyprogesterone, androstenedione, testosterone, 5α-dihydrotestosterone, 5α-androstanedione, androsterone and 5α-androstane-3α, 17β-diol in 1- to 2-ml samples of both blood serum and amniotic fluid as well as in 300- to 600-mg pieces of prostatic tissue. The adaptation of the pipetting unit and incubator of a discrete clinical chemical analyser, System Olli 3000, for the automation of the radioimmunoassays has resulted in a greatly increased through-put and has decreased the experimental error of the procedure. In studies on reproductive endocrinology, the methodology developed has allowed the detection of a sex difference in androgen composition of the amniotic fluid early in pregnancy. Further, it is very likely that the decline in steroid production by the testis seen during the first year of life and then in senescence is affected by basically different mechanisms. There are also important differences in the steroid content of normal, hyperplastic and carcinomatous prostate. (author)

  19. Multiple steroid radioimmunoassays and automation: versatile techniques for reproductive endocrinology

    International Nuclear Information System (INIS)

    Vihko, R.; Hammond, G.L.; Pakarinen, A.; Viinikka, L.

    1977-01-01

    The combination of the efficient steroid separating properties of a lipophilic Sephadex derivative Lipidex-5000sup(TM), with the use of antibodies with carefully selected specificity allows the quantitative determination of pregnenolone, progesterone, 17α-hydroxyprogesterone, androstenedione, testosterone, 5α-dihydrotestosterone, 5α-androstanedione, androsterone and 5α-androstane-3α, 17β-diol from 1-2 ml samples of blood serum, amniotic fluid or 300-600 mg pieces of prostatic tissue. The adaptation of the pipetting unit and incubator of a discrete clinical chemical analyzer, System Olli 3000, for the automation of the radioimmunoassays has resulted in a greatly increased through-put and decreased experimental error of the procedure. In studies on reproductive endocrinology, the methodology developed has allowed the detection of a sex difference in androgen composition of the amniotic fluid early in pregnancy. Further, it is very likely that the decline in steroid production by the testis seen during the first year of life and then in senescence is affected by basically different mechanisms. There are also important differences in the steroid content of normal, hyperplastic and carcinomatous prostate. (orig.) [de

  20. Improved performance of a double antibody radioimmunoassay for carcinoembryonic antigen

    International Nuclear Information System (INIS)

    Zimmerman, R.

    1979-01-01

    A new double antibody solid-phase radioimmunoassay (RIA) for carcinoembryonic antigen (CEA) is critically analyzed. The aim of the study was 4-fold: (a) to define the level of sensitivity (a comparison of 3 different assay procedures revealed that the author's sequential assay was more sensitive than most previously reported RIAs, while competitive and non-equilibrium assay had wider measuring ranges); (b) to analyze recoveries of CEA in either serum, plasma or urine (the recovery , even in urine, was very close to expected values, indicating that no CEA is lost or degraded during brief storage or in the extraction procedure); (c) to evaluate inter- and intra-assay variations, since most clinical management is dependent on serial assays rather than single determinations. The coefficients of variation were low both within and between assays. A change of 3 ng CEA is required for significant change (>2 S.D.) at the normal serum level which is 16 ng CEA/ml in the authors assay. At levels above normal, a change of 4 ng is required; (d) the assay was also developed for determination of CEA levels in a large series of perchlorid acid treated serum, plasma or urine samples. This forms the basis for an assay suitable for serial assays with high sensitivity and accuracy in various neoplastic diseases. (Auth.)

  1. Radioimmunoassay of antidiuretic hormone in human urine. Applications

    International Nuclear Information System (INIS)

    Zebidi, Abdelkrim.

    1977-10-01

    This work is devoted mainly to the development of a radioimmunological system of antidiuretic hormone (ADH) determination in the urine and its physiological and pathological applications. The radioimmunological method thus replaces the biological measurement of antidiuretic hormone in the urine. This new technique was not possible until specific arginine vasopressin antibodies were obtained and a labelled hormone was prepared according to the criteria set for a radioimmunoassay. The labelled hormone is lysine vasopressin (greater stability). Although 125 I-LVP has lost most of its biological activity the molecule keeps all its immunological properties, behaving in the same way as non-iodinated synthetic LVP towards anti-LVP antibodies. Once specific antivasopressin antibodies and immunologically competent labelled hormone were available, conditions were defined for the radioimmunological ADH test in the urine. This technique, relatively easy to use, allows twenty samples to be measured simultaneously. With this sensitive, specific and reproducible method, it is thus possible to estimate the urinary ADH excretion rates from a 20 ml volume of urine after previous extraction on amberlite CG 50. This extraction method is aimed at both concentrating the hormone and eliminating non-specific interferences. The hormone extraction yield is about 92%+-8 [fr

  2. Measurement of guinea pig eosinophil major basic protein by radioimmunoassay

    International Nuclear Information System (INIS)

    Wassom, D.L.; Loegering, D.A.; Gleich, G.J.

    1979-01-01

    Guinea pig eosinophil major basic protein (MBP) was measured by radioimmunoassay (RIA) using 131 I-MBP. Two critical features of the assay were: (1) alkylation of the MBP with iodoacetamide prior to radioiodination and (2) inclusion of another basic protein, either protamine or histone, in the phosphate buffer. Freshly isolated non-alkylated MBP was immunologically deficient when compared to alkylated or reduced MBP, but its reactivity could be redtores by reduction with dithiothreitol and alkylation. Reduction and alkylation also restored the immunoreactivity of polymerized MBP. MBP levels were not elevated in sera from guinea pigs parasitized with Trichinella spiralis and having peripheral blood eosinophilia. Muscle extracts from Trichinella infected animals showed significantly higher levels of MBP activity than normal controls. MBP was measurable in extracts of untreated eosinophils, but reduction and alkylation of these extracts increased MBP activity several fold. The RIA permits detection of MBP in body fluids and tissues at levels as low as 2 ng./ml. The RIA is useful in assessing increased or decreased levels of MBP activity in samples from experimental animals when compared to samples from controls. (author)

  3. The development of a radioimmunoassay for 18-hydroxy-corticosterone

    International Nuclear Information System (INIS)

    Martin, V.I.

    1980-03-01

    It has been suggested that 18-hydroxy-corticosterone (18-OH-B) is a precursor for aldosterone in the biosynthetic pathway. This steroid had not been measured in peripheral plasma and therefore to evaluate its clinical role a sensitive and specific radioimmunoassay was developed. The assay is described and was applied to measure the levels of 18-hydroxy-corticosterone in normal human subjects on (a) an ad libitum sodium intake whilst lying or standing, (b) on a high or low sodium intake whilst recumbent, (c) before and after treatment with either ACTH, metyrapone or dexamethasone on a high or low sodium intake whilst recumbent (d) after insulin induced hypoglycaemia and (e) after infusions of 18-hydroxy-corticosterone. The levels of 18-hydroxy-corticosterone were also measured in patients with (a) 17α-hydroxylase deficiency, (b) primary or secondary aldosteronism, (c) Bartter's syndrome, (d) Cushing's syndrome, (e) adrenalectomised patients or patient's with Addison's disease and (f) patients with essential hypertension. (author)

  4. Development of a radioimmunoassay for 18-hydroxy-corticosterone

    Energy Technology Data Exchange (ETDEWEB)

    Martin, V I

    1980-03-01

    It has been suggested that 18-hydroxy-corticosterone (18-OH-B) is a precursor for aldosterone in the biosynthetic pathway. This steroid had not been measured in peripheral plasma and therefore to evaluate its clinical role a sensitive and specific radioimmunoassay was developed. The assay is described and was applied to measure the levels of 18-hydroxy-corticosterone in normal human subjects on (a) an ad libitum sodium intake whilst lying or standing, (b) on a high or low sodium intake whilst recumbent, (c) before and after treatment with either ACTH, metyrapone or dexamethasone on a high or low sodium intake whilst recumbent (d) after insulin induced hypoglycaemia and (e) after infusions of 18-hydroxy-corticosterone. The levels of 18-hydroxy-corticosterone were also measured in patients with (a) 17chemically bond-hydroxylase deficiency, (b) primary or secondary aldosteronism, (c) Bartter's syndrome, (d) Cushing's syndrome, (e) adrenalectomised patients or patient's with Addison's disease and (f) patients with essential hypertension. (author).

  5. Separation of lactoferrin and clinical application of its radioimmunoassay

    International Nuclear Information System (INIS)

    Qiang Yizhong; Wang Chongdao; Jin Jian

    1995-02-01

    A new method of separation and purification of lactoferrin (LF), its radioimmunoassay (LF-RIA), and application in the diagnosis of lung cancer are reported. The results showed that this method is much better than what were previously reported, with advantages of high yield, time-saving and economy. The results of the LF-RIA established were good. The coefficients of variation within a batch and between batches were 4.77% and 13.59% respectively and the recovery rate was 97.99%. There was no cross-reaction between lactoferrin and transferrin. The lactoferrin in the bronchial washing fluid (BLF) was determined in 36 lung cancer cases, 21 pulmonary infection cases and 4 normal controls. The results indicated that the BLF content in the lung cancer group was higher than that in the pulmonary infection group or the normal control group and the detection rate was the highest in lung adenocarcinoma. Pathological analysis indicated that the BLF was negatively related to the early and later tumor. (2 figs., 2 tabs.)

  6. Radioimmunoassay of human cardiac tropomyosin in acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Cummins, P; McGurk, B; Littler, W A [Queen Elizabeth Hospital, Birmingham (UK)

    1981-03-01

    Tropomyosin was prepared from fresh human myocardium and antisera raised in rabbits. A sensitive radioimmunoassay was developed for the detection of human cardiac /sup 125/I-labelled tropomyosin in human sera down to levels of 1 ng/ml. Values for human cardiac tropomyosin in normal patients ranged from less than 1 to 3 ng/ml. In 18 patients with acute myocardial infarction all had elevated tropomyosin levels ranging from 41 to above 200 ng/ml with a mean peak level of 101 ng/ml. In this study there were no false positive or false negative results. In the initial stages of infarction the time course of appearance and peak levels of cardiac tropomyosin, total creatine kinase and creatine kinase MB isoenzyme were similar. Although total creatine kinase and creatine kinase MB isoenzyme levels were normal after 72 h in patients with single, uncomplicated infarction, cardiac tropomyosin levels were still significantly elevated above normal after this time, being 30-60% of peak valuctional hourly rate of absorption and the plasma /sup 32/P radioactivity at 60 min corrected for extracellular fluid volume provided the best app elements, the characteristics of which are determined by employing the Lagrange multiplier concept. Unknowns of the resulting simultaneous equation consist of usual nodal displacements of the whole stru element codes. Therefore, FAST should be useful in several areas for which all other codes are too unwieldy and expensivnt makers was established, in which the investigations and studies have started.

  7. Radioimmunoassay for progesterone in human saliva during the menstrual cycle

    Energy Technology Data Exchange (ETDEWEB)

    Luisi, M.; Franchi, F.; Kicovic, P.M.; Silvestri, D.; Cossu, G.; Catarsi, A.L.; Barletta, D.; Gasperi, M. (Pisa Univ. (Italy))

    1981-10-01

    A sensitive, specific and accurate radioimmunoassay of progesterone in human saliva is described, using /sup 3/H. The assay had a sensitivity of 8 pg/tube and blanks were negligible. The intra- and inter-assay coefficients of variation were 5.2 and 9.4%, respectively. The mean recovery from 60 samples was 93.2 +- 6.3%. Results obtained from nine healthy, normally menstruating women showed that salivary progesterone rose from the 4th day before ovulation to a mean peak (+- SD) of 1.14 +- 0.17 ng/ml on the 8th day after ovulation, followed by a gradual decline. Correlation of salivary and simultaneously obtained plasma progesterone levels was good (r = 0.47; P < 0.001), although the maximum percent increase in salivary progesterone was more than 10 times greater than that of plasma progesterone. Salivary progesterone is thought to reflect the unbound fraction of plasma progesterone and this non-invasive technique can be used for serial investigations in which frequent samplings are required.

  8. Development and clinical application of human gastrin radioimmunoassay

    International Nuclear Information System (INIS)

    Ginabreda, M.G.P.; Borghi, V.C.; Bettarello, A.

    1988-08-01

    The determination of human gastrin levels in the blood is very important for diagnosis of gastrointestinal disorders. This work describes the radioimmunoassay of gastrin developed according to Russell et al. and its clinical application measuring fasting levels of this hormone in normal subjects, gastrectomized, chagasics, patients with chronic renal failure (CRF), pernicious anemia (PA) and Zollinger-Ellison syndrome (ZES). Synthetic human gastrin was used for radioiodination and as standard, while the specific antibody was raised in rabbits. Gastrin was radioiodinated by a modification of the chloramine T technique and purified by anion exchange chromatography in QAE-Sephadex A-25 to a specific activity around 200 uCi/ug. The assays were performed by incubation of 125 I-gastrin, standard gastrin (zero to 500 pmol/l) or unknown samples with the antiserum for 4 days at 4 0 C. The antibody bound and free 125 I-gastrin was separated by adsorption of the latter to the charcoal. The basal gastrin values of normal subjects ranged from 2 to 74 pmol/l, being these levels higher in the chagasics (from 6 to 261 pmol/l). Higher levels of gastrin were determined in patients with CRF (from 12 to 350 pmol/l), PA (from 160 to 680 pmol/l) and with ZES(1010 pmol/l), while very low levels were confirmed in gastrectomized (from 1 to 8 pmol/l). (author) [pt

  9. Immunochemical studies on thymosin: radioimmunoassay of thymosin α1

    International Nuclear Information System (INIS)

    McClure, J.E.; Lameris, N.; Wara, D.W.; Goldstein, A.L.

    1982-01-01

    A sensitive and specific radioimmunoassay (RIA) has been developed to measure thymosin α 1 in human blood and tissue extracts. Thymosin α 1 originally isolated from bovine thymosin fraction 5, has an identical primary structure in bovine and human species. Antiserum to synthetic thymosin α 1 was prepared in rabbits. A synthetic analogue, N-Ac-(Tyr 1 )thymosin α 1 was radioiodinated by utilizing Na 125 I and soluble lactoperoxidase. The RIA is capable of detecting as small an amount as 40 pg thymosin α 1 in serum/plasma and does not significatly cross-react with other putative thymic hormones or other purified blood proteins that have been assayed. Proteolytic degradation of thymosin α 1 does not occur during the collection, storage, or assay of serum or plasma. The concentration of thymosin α 1 in blood is highest in utero, decreases sharply after birth, and appears to remain fairly constant during the first 15 yr of life. Maternal blood levels of thymosin α 1 appear to be above normal during pregnancy

  10. Radioimmunoassay in the diagnosis of atypical form of thyrotoxicosis

    International Nuclear Information System (INIS)

    Livshits, G.Ya.

    1984-01-01

    Fifty-six patients with ''unmotivated'' disorder of the cardiac rhythm were examined. A combined radionuclide study including a study of iodoabsorptive function with a standard technique, thyroid visualization and determination of the thyroxin, triiodothyronine level in the blood serum with the radioimmunoassay using standard diagnostic kits, was conducted, Latent thyroid hyperfunction was revealed in 24 patients (42.8%). Study of iodoabsorptive function revealed pathological changes in 8 patients only, whereas raaioimmunoassay revealed a significant elevation of the peripheral thyroid hormone level as compared to that of the control group in 24 patients. The conclusion is that patients with ''unmotivated'' disorder of the cardiac rhythm often suffer from latent thyrotoxicosis which is the main etiological factor and trigger mechanism of arrhythmias. In such a situation they are the only clinical symptom of thyrotoxicosis that makes it possible to regard this form of disease as monosymptomatic. The early detection of the cause of cardiac rhythm disorder and the prescription of pathogenetic thyrostatic therapy resulted in the return of the cardiac cycle rate to normal in all the patients with sinus tachycardia and prevented relapses of the paroxysmal forms of rhythm disorder

  11. Evidence for carcinoembryonic antigen using radioimmunoassay and enzyme immunoassay

    International Nuclear Information System (INIS)

    Kungda Gao, L.

    1980-01-01

    A commercially available radioimmunoassay for the determination of carcinoembryonic antigen (CEA) was initially compared with an enzyme immunoassay (EIA). Considerable differences were found between the individual value. For three patients suffering from carcinomas of the digestive tract a better indication of the disease was given in the RIA than in the EIA. A further 110 patients with various illnesses were examined for serum CEA-levels using RIA. A method for measuring CEA in feces by RIA was developed. The normal range lies below 300 ng/ml. This assay could be of significance for the early recognition of colo-rectal carcinoma. In part II of this dissertation CEA was isolated from colo-rectal carcinomas using three different gel filtration media. It was only possible to obtain almost pure CEA (24 μg CEA per μg protein) by one of the methods. Six guinea pigs were immunized with the isolated CEA and all developed antibodies. The isolated CEA was labelled with 125 I and an own RIA saturation sequence and double antibody separation was developed. One of the antisera was able to distinguish without overlap 7 healthy patients from 7 suffering from colo-rectal carcinomas in non-extracted serum. (orig./MG) [de

  12. Specific radioimmunoassay of human. beta. -endorphin in unextracted plasma

    Energy Technology Data Exchange (ETDEWEB)

    Wiedemann, E. (Univ. of California, Berkeley); Saito, T.; Linfoot, J.A.; Li, C.H.

    1979-09-01

    With an antiserum against human ..beta..-endorphin (..beta..-EP) crossreacting <2% with human ..beta..-lipotropin (..beta..-LPH) by weight we have developed a radioimmunoassay that can detect 1 pg ..beta..-EP in diluted raw plasma. In a.m. fasting plasma of 14 normal subjects ..beta..-EP ranged from <5 to 45 pg/ml. ..beta..-EP was elevated in untreated, but normal in successfully treated Cushing's disease; undetectable in a patient with adrenal adenoma; extremely high in Nelson's syndrome; and elevated in a patient with bronchogenic carcinoma before, but undetectable after tumor resection. In subjects with intact hypothalamic-pituitary-adrenal axis, ..beta..-EP was undectectable after dexamethasone and increased after metyrapone administration and insulin-induced hypoglycemia. ..beta..-EP concentration was considerably lower in serum than in simultaneously collected plasma, but increased in serum left unfrozen for several hours after clot removal. Thus, ..beta..-EP behaves like a hormone responding to the same stimuli as ACTH and ..beta..-LPH and blood appears to contain enzymes both generating and destroying immunoreactive ..beta..-EP.

  13. A radioimmunoassay for lignin in plant cell walls

    International Nuclear Information System (INIS)

    Dawley, R.M.

    1989-01-01

    Lignin detection and determination in herbaceous tissue requires selective, specific assays which are not currently available. A radioimmunoassay (RIA) was developed to study lignin metabolism in these tissues. A β-aryl ether lignin model compound was synthesized, linked to keyhole limpet hemocyanin using a water-soluble carbodiimide, and injected into rabbits. The highest titer of the antiserum obtained was 34 ηg/mL of model derivatized BSA. An in vitro system was developed to characterize the RIA. The model compound was linked to amino activated polyacrylamide beads to mimic lignin in the cell walls. 125 I Radiolabelled protein A was used to detect IgG antibody binding. The RIA was shown in the in vitro system to exhibit saturable binding. The amount of antibody bound decreased when the serum was diluted. Immunoelectrophoresis and competitive binding experiments confirmed that both aromatic rings of the lignin model compound had been antigenic. Chlorogenic acid, a phenolic known to be present in plant cells, did not compete for antibody binding. The RIA was used to measure lignin in milled plant samples and barley seedlings. Antiserum binding to wheat cell walls and stressed barley segments was higher than preimmune serum binding. Antibody binding to stressed barley tissue decreased following NaClO 2 delignification. The RIA was found to be less sensitive than expected, so several avenues for improving the method are discussed

  14. An Evaluation by TSH Radioimmunoassay on Familial Thyroid Disorders

    International Nuclear Information System (INIS)

    Kim, Ji Yeul

    1989-01-01

    The occurrence of thyroid disorders is connected with iodine deficiency, defective synthesis or releasing of thyroid hormone and endemicity. Genetic factors are known as a single gene defects, interaction of multiple genes with environmental factors, as well as chromosomal aberrations. Diofnosis thyroid disorders is enforced by 13I uptake test, thyroid scanning with 131 I or 99m Tc and serum radioimmunoassays of T3, T4, free T4 and TSH. They were largely classified as hypothyroidism, hyperthyroidism, simple goiter and normal. The pedigree of 58 families was drawn by propositus, and then the correlation between thyroid disorders and TSH levels was analyzed. The results are as follows: 1) The offsprings and their mothers of 15 families were hypothyroidism, THS level was 5 folds for offsprings and 4 folds for mothers in comparison with control group. 2) 13 families were hyperthyroidism in siblings but their mothers were normal in thyroid function, TSH level of the siblings was lower than control group. 3) Though the offsprings and their mothers of 10 families were similar to TSH level of control group, they are all simple goiter, familial thyroid disorders, in other thyroid function test. The familial thyroid disorders suggested that these transmitted from mothers to offsprings with X-linked dominant or autosomal dominant inheritance.

  15. Radioimmunoassay of erythropoietin: analytical performance and clinical use in hematology.

    Science.gov (United States)

    Schlageter, M H; Toubert, M E; Podgorniak, M P; Najean, Y

    1990-10-01

    We report here the performance of a recently commercialized radioimmunoassay kit for determining erythropoietin (EPO) in serum or plasma. The lower detection limit of the method was 3 U/L. Precision, analyzed by the variation coefficients between different assay runs and in the same experiment, was always less than 10%; accuracy was assessed by recovery and dilution tests. In anemic patients (hematocrit 18-39%), the concentration of EPO was logarithmically related to hematocrit. A relatively large dispersion of the results was noted, as reported by others with various RIAs. Patients with severe renal failure demonstrated a very low EPO value, whatever the degree of their anemia. In some chronic anemias resulting from malignancy, EPO concentrations were also relatively low. In the polycythemia vera group, the EPO mean was below normal for greater than 95% of the patients, whatever their clinical stage (first evaluation, relapse, or remission). In contrast, 91% of the patients with pure erythrocytosis had a normal or increased EPO value, even when the etiology was unknown. Measurement of EPO concentration may be useful for the clinical differentiation of myeloproliferative disorders and, subsequently, for their prognosis and choice of treatment.

  16. Precision of radioimmunoassays by various types of data processing systems

    International Nuclear Information System (INIS)

    Ujiie, Morimichi

    1979-01-01

    The following are the result of the investigation of the precision of radioimmunoassays by various types of data processing systems presently performed in Japan. Chose 50 facilities, where 10 facilities of clinical laboratories were included. Tested 334, 485 cases per month, which corresponds to 40% of the total number of the cases treated all over the country. It was known that the data of 74% of all facilities and 94% of all tests were being processed by computing machines. In 66 times of data processing of insulin and T3 measurements, 32 were performed by the hyperbola method, 11 by the log-logit curve method of secondary degree, 9 by the logistic curve method and 8 by the log-logit curve method of first degree. Practically in more than 90% of all cases were processed by these 4 types of curve methods. In insulin measurements of many standard points (8 points), favourable results could be obtained by the logistic curve method. On the contrary, in T3 measurements of fewer standard points (5 points), the results from the method of log-logit curve of secondary degree were good. Favourable results of both insulin and T3 measurements could be obtained by the hyperbola method. While, in the insulin measurement by the method of log-logit curve of first degree, the values were a bit lower in the higher and lower concentration ranges, and 3 -- 4% higher than the actual values in the middle concentration range. (author)

  17. Serum gastrin: interests and limitations of radio-immunoassay

    International Nuclear Information System (INIS)

    Rougier, P.; Linhart, N.; Bok, B.

    1980-01-01

    Radio-immunoassay of serum gastrin may now be carried out in all laboratories of radio-immunology. Comparison of two commercial kits A: Schwartz-Mann and B: CEA-SORIN according to criteria of specificity, sensitivity and reproducibility within and between systems, shows that they both permit the detection of pathological hypergastrinemias (Zollinger Ellison and atropic gastritis). Both kits have an identical intrasystem coefficient of variation (10 p. cent and 7 p. cent fort A, 5 p. cent and 8 p. cent for B) on the other hand, the inter-system coefficient of variation is better for kit B (22.4 p. cent and 37 p. cent for kit A, and 11.5 p. cent and 14.2 p. cent for kit B). The normal values for each kit are quite different: 97 . 64 pg.ml -1 for A and 51 . 23 pg.ml -1 for B preventing one from comparing estimations carried out with two different kits [fr

  18. Avian LH and FSH: comparison of several radioimmunoassays

    International Nuclear Information System (INIS)

    Goldsmith, A.R.; Follett, B.K.

    1983-01-01

    Comparisons were made between various LH and FSH radioimmunoassays currently being used to measure avian hormones. The two LH assays were the homologous chicken system of Follett et al. (1972) and the turkey assay of Burke et al. (1979). These assays were also used in heterologous arrangement by interchanging the iodinated LH fractions and antisera. Five FSH assays were analyzed: two homologous chicken systems (Scanes et al., 1977; Sakai and Ishii, 1980) an assay based on mammalian materials (rat FSH and anti-ovine FSH antiserum, and one using labelled turkey FSH (Burke et al., 1979) with an anti-chicken FSH antiserum. The potencies of purified chicken and turkey gonadotrophin preparations and of a range of plasma samples from Japanese quail were measured in each assay. The two LH systems showed some degree of species specificity, such that chicken LH was more active than turkey LH in the chicken assay, whereas the reverse was true in the turkey LH assay. The potency estimates of the purified hormones in the various FSH assays were very consistent. The qualitative changes in plasma hormone levels were similar in all assays, although there were some differences in the magnitude of the responses

  19. Laboratory training manual on radioimmunoassay in animal reproduction

    International Nuclear Information System (INIS)

    1984-01-01

    Reproduction must always be regarded as one of the major limiting factors in animal production and many of the modern methods for improving reproduction rely heavily on the ability to measure hormone levels in blood and milk. This has produced a world-wide demand for laboratory facilities to carry out hormone assays and the need for specialist training to allow these assays to be undertaken. The need to measure nanogram and picogram quantities and the use of radionuclides require a good deal of skill and care and this Manual has been prepared to aid training and provide the sort of information that rarely appears in scientific papers. It represents a further step in the Joint FAO/IAEA Division's series of Laboratory Training Manuals, and has been designed to aid training programmes of the type carried out during the Joint FAO/IAEA Interregional Training Course on Radioimmunoassay and its Application in Research on Animal Reproduction at Cornell University in July 1982. Many of the laboratory exercises described in this Manual are based on those conducted during the course

  20. The studies on aldosterone secretion rate by radioimmunoassay

    International Nuclear Information System (INIS)

    Takenouchi, Takahiko

    1974-01-01

    The aldosterone secretion rate was measured by radioimmunoassay in 12 normal subjects and 47 hypertensive patients. The values ranged from 25.0 to 60.2 ng/day with a mean of 39.6+-10.7 (S.D.) in 8 normal males and from 30.2 to 85.4 ng/day with a mean of 62.6+-26.8 (S.D.) in 4 normal females. The mean value in 21 cases with benign essential hypertension was found to be within normal range. No significant difference was found in the aldosterone secretion rate between the group of benign essential hypertension with suppressed renin activity and with nonsuppressed renin activity. Metabolic clearance rate in benign essential hypertension was observed to be within normal range. The aldosterone secretion rate in a few cases of benign essential hypertension failed to increase normally in response to sodium restriction (<50 mEq/day). The values in 11 cases of primary aldosteronism were found to be clearly higher, when compared with the values of normal subjects and subjects with benign essential hypertension. High values were found in patients suffering from malignant hypertension and in 3 with unilateral renal artery stenosis. The values in cases of bilateral renal artery stenosis, of pheochromocytoma, and of acromegaly with hypertension were within normal range. Low values in the aldosterone secretion rate were found in 3 cases each of 17α-hydroxylase deficiency and Cushing's syndrome. (JPN)