WorldWideScience

Sample records for two-meter diameter jp-8

  1. Soot properties and species measurements in a two-meter diameter JP-8 pool fire.

    Energy Technology Data Exchange (ETDEWEB)

    Shaddix, Christopher R.; Murphy, Jeffrey J.

    2003-06-01

    A tunable diode laser absorption spectroscopy probe was used to measure in situ soot properties and species concentrations in two-meter diameter JP-8 pool fires. Twelve tests were performed at the Lurance Canyon Bum Site operated by Sandia in Albuquerque, New Mexico. Seven of the tests were conducted with the probe positioned close to the centerline at heights above the pool surface ranging from 0.5 m to 2.0 mm in 0.25 m increments. For the remaining five tests, the probe was positioned at two heights 0.3 m from the centerline and at three heights 0.5 m from the centerline. Soot concentration was determined using a soot absorption measurement based on the transmission of a solid-state red laser (635 nm) through the 3.7 cm long probe volume. Soot temperature and a second estimate of soot concentration were measured using two-color optical pyrometry at 850 nm and la00 nm. The effective data rate for these measurements was 10 Mz. Finally, tunable diode laser absorption spectroscopy was used to qualitatively estimate water concentration at a rate of 1 kHz. To improve signal-to-noise, these data were averaged to an effective rate of 2 Hz. The results presented include the statistics, probability density functions, and spectral density functions of soot concentration, soot temperature, and approximate water concentrations at the different measurement locations throughout the fire.

  2. Soot properties and species measurements in a two-meter diameter JP-8 pool fire : 2003 test series.

    Energy Technology Data Exchange (ETDEWEB)

    Shaddix, Christopher R.; Murphy, Jeffrey J.

    2004-03-01

    A tunable diode laser absorption spectroscopy probe was used to measure in situ soot properties and species concentrations in a two-meter diameter JP-8 pool fire. Thirty-five tests were performed at the Lurance Canyon Burn Site operated by Sandia in Albuquerque, New Mexico. The axial profile of the fire was characterized with a series of tests with the probe located on the centerline at heights ranging from 0.5 m to 2.0 m in 0.25 m increments. The radial profile of the fire was characterized with a series of tests with the probe 1.0 m above the fuel surface at radial positions ranging from 0.0 m to 0.6 m, in 0.1 m increments. Experiments were also performed with variation of the air flow into the facility. Soot concentration was determined using a light extinction measurement based on the transmission of a solid-state red laser (635 nm) through the 3.7 cm long probe volume. Soot temperature and a second estimate of soot concentration were measured using two-color optical pyrometry at 850 nm and 1000 nm. The effective data rate for these measurements was 10 kHz. Finally, tunable diode laser absorption spectroscopy was used to estimate the concentrations of water vapor, acetylene, and methane. The results presented include the statistics, probability density functions, and spectral density functions of soot concentration, soot temperature, and approximate species concentrations at the different measurement locations throughout the fire.

  3. Characterization of soot properties in two-meter JP-8 pool fires.

    Energy Technology Data Exchange (ETDEWEB)

    Suo-Anttila, Jill Marie; Jensen, Kirk A.; Blevins, Linda Gail (Sandia National Laboratories, Livermore, CA)

    2005-02-01

    The thermal hazard posed by large hydrocarbon fires is dominated by the radiative emission from high temperature soot. Since the optical properties of soot, especially in the infrared region of the electromagnetic spectrum, as well as its morphological properties, are not well known, efforts are underway to characterize these properties. Measurements of these soot properties in large fires are important for heat transfer calculations, for interpretation of laser-based diagnostics, and for developing soot property models for fire field models. This research uses extractive measurement diagnostics to characterize soot optical properties, morphology, and composition in 2 m pool fires. For measurement of the extinction coefficient, soot extracted from the flame zone is transported to a transmission cell where measurements are made using both visible and infrared lasers. Soot morphological properties are obtained by analysis via transmission electron microscopy of soot samples obtained thermophoretically within the flame zone, in the overfire region, and in the transmission cell. Soot composition, including carbon-to-hydrogen ratio and polycyclic aromatic hydrocarbon concentration, is obtained by analysis of soot collected on filters. Average dimensionless extinction coefficients of 8.4 {+-} 1.2 at 635 nm and 8.7 {+-} 1.1 at 1310 nm agree well with recent measurements in the overfire region of JP-8 and other fuels in lab-scale burners and fires. Average soot primary particle diameters, radius of gyration, and fractal dimensions agree with these recent studies. Rayleigh-Debye-Gans theory of scattering applied to the measured fractal parameters shows qualitative agreement with the trends in measured dimensionless extinction coefficients. Results of the density and chemistry are detailed in the report.

  4. Woody Biomass Conversion to JP-8 Fuels

    Science.gov (United States)

    2014-02-15

    the downstream hydrotreating required to produce a drop-in transportation fuel. Furthermore, this process does not use a catalyst, making it tolerant...Approximately 40% of the hydrotreated TDO oil mass is in the JP-8 (180-250C), and 60% is in the F-76 (150-325C) boiling point range, respectively

  5. Forecasting USAF JP-8 Fuel Needs

    Science.gov (United States)

    2009-03-01

    Homogeneous Charge Compression Ignition, or HCCI , which combines the best features of gasoline- and diesel-powered engines . The results could be up...FORECASTING USAF JP-8 FUEL NEEDS THESIS Presented to the Faculty Department of Logistics Management Graduate School of Engineering and Management...2008). Jet fuel is: ‘Kerosene-type; high-quality kerosene product used primarily as fuel for commercial turbojet and turboprop aircraft engines ’ (New

  6. JP-8 catalytic cracking for compact fuel processors

    Science.gov (United States)

    Campbell, Timothy J.; Shaaban, Aly H.; Holcomb, Franklin H.; Salavani, Reza; Binder, Michael J.

    In processing heavier hydrocarbons such as military logistic fuels (JP-4, JP-5, JP-8, and JP-100), kerosene, gasoline, and diesel to produce hydrogen for fuel cell use, several issues arise. First, these fuels have high sulfur content, which can poison and deactivate components of the reforming process and the fuel cell stack; second, these fuels may contain non-volatile residue (NVR), up to 1.5 vol.%, which could potentially accumulate in a fuel processor; and third is the high coking potential of heavy hydrocarbons. Catalytic cracking of a distillate fuel prior to reforming can resolve these issues. Cracking using an appropriate catalyst can convert the various heavy organosulfur species in the fuel to lighter sulfur species such as hydrogen sulfide (H 2S), facilitating subsequent sulfur adsorption on zinc oxide (ZnO). Cracking followed by separation of light cracked gas from heavies effectively eliminates non-volatile aromatic species. Catalytic cracking can also convert heavier hydrocarbons to lights (C 1-C 3) at high conversion, which reduces the potential for coke formation in the reforming process. In this study, two types of catalysts were compared for JP-8 cracking performance: commercially-available zeolite materials similar to catalysts formulated for fluidized catalytic cracking (FCC) processes, and a novel manganese/alumina catalyst, which was previously reported to provide high selectivity to lights and low coke yield. Experiments were designed to test each catalyst's effectiveness under the high space velocity conditions necessary for use in compact, lightweight fuel processor systems. Cracking conversion results, as well as sulfur and hydrocarbon distributions in the light cracked gas, are presented for the two catalysts to provide a performance comparison.

  7. Effects of JP-8 Jet Fuel on Homeostasis of Clone 9 Rat Liver Cells

    Science.gov (United States)

    Wilson, C. L.; Barhoumi, R.; Burghardt, R.; Miladi, A.; Jung, A.

    2000-01-01

    Chronic exposure to JP-8 and other kerosene-based petroleum distillates has been associated with hepatic, renal, neurologic, pulmonary, and immune toxicity. However, the effects of kerosene-type jet fuels on cellular homeostasis hitherto have not been reported. Fluorescence imaging using a Meridian Ultima laser scanning fluorescence microscope was used to evaluate the effect of JP-8 jet fuel on a communication competent rat liver cell line. Several endpoints of cellular function were measured including gap junctional intercellular communication (GJIC), mitochondrial and plasma membrane potential (MMP and PMP, respectively), intracellular glutathione (GSH) concentration, glutathione-S-transferase (GST) activity, and reactive oxygen species (ROS) generation. Cells were treated with JP-8 (0.01 to 2% in ethanol (EtOH)) for the following time points: 1 h, 24 h, 48 h, and analysis immediately after addition of jet fuel. GJIC analyzed directly after addition of 1% JP-8 was reduced 4.9-fold relative to EtOH-dosed control groups and further reduction (12.6-fold) was observed in cells treated for 1 h. Moreover, GJIC was not recoverable in cells treated with 1% JP-8 for 1 h and subsequently washed and incubated in fresh medium for 1 h. Significant changes in GSH content and GST activity were observed in cells analyzed directly after addition of 1% JP-8. GSH content increased in cells treated for 1 h with less than 2% JP-8 whereas treatment with 2% JP-8 for 1 h resulted in a 50% reduction in intracellular GSH relative to EtOH-dosed controls. Cells treated with 1% JP-8 for 48 h exhibited changes in GSH levels. However, higher JP-8 concentrations exhibited more pronounced changes in GSH and GST, which led to suppression of GSH synthesis. ROS increased in a dose-responsive fashion at JP-8 concentrations up to 1%, but decreased to 80% of control values at 2% and 3% JP-8. A 25% reduction in PMP was observed in cells treated for 1 h with 1% JP-8. In contrast, cells treated for 48 h

  8. The Effect of Fuel Injector Nozzle Configuration on JP-8 Sprays at Diesel Engine Conditions

    Science.gov (United States)

    2014-10-01

    The Effect of Fuel Injector Nozzle Configuration on JP-8 Sprays at Diesel Engine Conditions by Matthew Kurman, Luis Bravo, Chol-Bum Kweon...Fuel Injector Nozzle Configuration on JP-8 Sprays at Diesel Engine Conditions Matthew Kurman, Luis Bravo, and Chol-Bum Kweon Vehicle Technology...March 2014 4. TITLE AND SUBTITLE The Effect of Fuel Injector Nozzle Configuration on JP-8 Sprays at Diesel Engine Conditions 5a. CONTRACT NUMBER 5b

  9. Systemic molecular and cellular changes induced in rats upon inhalation of JP-8 petroleum fuel vapor.

    Science.gov (United States)

    Hanas, Jay S; Bruce Briggs, G; Lerner, Megan R; Lightfoot, Stan A; Larabee, Jason L; Karsies, Todd J; Epstein, Robert B; Hanas, Rushie J; Brackett, Daniel J; Hocker, James R

    2010-05-01

    Limited information is available regarding systemic changes in mammals associated with exposures to petroleum/hydrocarbon fuels. In this study, systemic toxicity of JP-8 jet fuel was observed in a rat inhalation model at different JP-8 fuel vapor concentrations (250, 500, or 1000 mg/m(3), for 91 days). Gel electrophoresis and mass spectrometry sequencing identified the alpha-2 microglobulin protein to be elevated in rat kidney in a JP-8 dose-dependent manner. Western blot analysis of kidney and lung tissue extracts revealed JP-8 dependent elevation of inducible heat shock protein 70 (HSP70). Tissue changes were observed histologically (hematoxylin and eosin staining) in liver, kidney, lung, bone marrow, and heart, and more prevalently at medium or high JP-8 vapor phase exposures (500-1000 mg/m(3)) than at low vapor phase exposure (250 mg/m(3)) or non-JP-8 controls. JP-8 fuel-induced liver alterations included dilated sinusoids, cytoplasmic clumping, and fat cell deposition. Changes to the kidneys included reduced numbers of nuclei, and cytoplasmic dumping in the lumen of proximal convoluted tubules. JP-8 dependent lung alterations were edema and dilated alveolar capillaries, which allowed clumping of red blood cells (RBCs). Changes in the bone marrow in response to JP-8 included reduction of fat cells and fat globules, and cellular proliferation (RBCs, white blood cells-WBCs, and megakaryocytes). Heart tissue from JP-8 exposed animals contained increased numbers of inflammatory and fibroblast cells, as well as myofibril scarring. cDNA array analysis of heart tissue revealed a JP-8 dependent increase in atrial natriuretic peptide precursor mRNA and a decrease in voltage-gated potassium (K+) ion channel mRNA.

  10. Test Record of Flight Tests Using Alcohol-to-Jet/JP-8 Blended Fuel

    Science.gov (United States)

    2015-09-01

    2. Fuel Storage Tank: The fuel storage tanker was completely drained and returned to BakerCorp IAW the lease agreement . 3. Aircraft: The...tests, use of the JP-8/ATJ blend was transparent to all fuel wetted systems including the engines. REFERENCES. 1. Test Record, Alcohol-to-Jet/JP-8

  11. JP-8 jet fuel can promote auditory impairment resulting from subsequent noise exposure in rats.

    Science.gov (United States)

    Fechter, Laurence D; Gearhart, Caroline; Fulton, Sherry; Campbell, Jerry; Fisher, Jeffrey; Na, Kwangsam; Cocker, David; Nelson-Miller, Alisa; Moon, Patrick; Pouyatos, Benoit

    2007-08-01

    We report on the transient and persistent effects of JP-8 jet fuel exposure on auditory function in rats. JP-8 has become the standard jet fuel utilized in the United States and North Atlantic Treaty Organization countries for military use and it is closely related to Jet A fuel, which is used in U.S. domestic aviation. Rats received JP-8 fuel (1000 mg/m(3)) by nose-only inhalation for 4 h and half of them were immediately subjected to an octave band of noise ranging between 97 and 105 dB in different experiments. The noise by itself produces a small, but permanent auditory impairment. The current permissible exposure level for JP-8 is 350 mg/m(3). Additionally, a positive control group received only noise exposure, and a fourth group consisted of untreated control subjects. Exposures occurred either on 1 day or repeatedly on 5 successive days. Impairments in auditory function were assessed using distortion product otoacoustic emissions and compound action potential testing. In other rats, tissues were harvested following JP-8 exposure for assessment of hydrocarbon levels or glutathione (GSH) levels. A single JP-8 exposure by itself at 1000 mg/m(3) did not disrupt auditory function. However, exposure to JP-8 and noise produced an additive disruption in outer hair cell function. Repeated 5-day JP-8 exposure at 1000 mg/m(3) for 4 h produced impairment of outer hair cell function that was most evident at the first postexposure assessment time. Partial though not complete recovery was observed over a 4-week postexposure period. The adverse effects of repeated JP-8 exposures on auditory function were inconsistent, but combined treatment with JP-8 + noise yielded greater impairment of auditory function, and hair cell loss than did noise by itself. Qualitative comparison of outer hair cell loss suggests an increase in outer hair cell death among rats treated with JP-8 + noise for 5 days as compared to noise alone. In most instances, hydrocarbon constituents of the fuel

  12. Conceptual Design of 500 watt portable thermophotovoltaic power supply using JP-8 fuel

    Science.gov (United States)

    DeBellis, Crispin L.; Scotto, Mark V.; Scoles, Stephen W.; Fraas, Lewis

    1997-03-01

    Babcock & Wilcox (B&W) and JX Crystals (JXC) have developed an innovative design for a compact, 500 watt net electric (We), 24-VDC thermophotovoltaic (TPV) power supply using JP-8 fuel. As currently envisioned, the TPV generator will be approximately 20 cm (8 inches) in diameter and 50 cm (20 inches) high, not including a fuel tank and controls. The total system may weigh as little as 7.5 kg (16.5 lb) without fuel. This system will achieve high efficiency and high power density relative to its size through the use of low bandgap gallium antimonide (GaSb) PV cells and a matched emitter. A thermally integrated fuel vaporizer and recuperator will boost system efficiency by transferring the unused energy in the exhaust stream to the incoming fuel and combustion air. At rated conditions and 500 We output, the system is expected to have an overall efficiency of 8% to 10%. This paper examines the trade-offs between system efficiency, power density, and weight required in the selection and configuration of the major system components.

  13. Impact of Military JP-8 Fuel on Heavy Duty Diesel Engine Performance and Emissions

    Science.gov (United States)

    2005-12-07

    Filipi, Z., Assanis, D., Kuo, T.-W., Najt, P., Rask, R. “New Heat Transfer Correlation for the HCCI Engine Derived from Measurements of...Impact of Military JP-8 Fuel on Heavy Duty Diesel Engine Performance and Emissions Gerald Fernandes1, Jerry Fuschetto1, Zoran Filipi1 and Dennis...with the operation of a diesel engine with JP- 8 fuel due to its lower density and viscosity, but few experimental studies suggest that kerosene

  14. Effect of JP-8 jet fuel exposure on protein expression in human keratinocyte cells in culture.

    Science.gov (United States)

    Witzmann, F A; Monteiro-Riviere, N A; Inman, A O; Kimpel, M A; Pedrick, N M; Ringham, H N; Riviere, J E

    2005-12-30

    Dermal exposure to jet fuel is a significant occupational hazard. Previous studies have investigated its absorption and disposition in skin, and the systemic biochemical and immunotoxicological sequelae to exposure. Despite studies of JP-8 jet fuel components in murine, porcine or human keratinocyte cell cultures, proteomic analysis of JP-8 exposure has not been investigated. This study was conducted to examine the effect of JP-8 administration on the human epidermal keratinocyte (HEK) proteome. Using a two-dimensional electrophoretic approach combined with mass spectrometric-based protein identification, we analyzed protein expression in HEK exposed to 0.1% JP-8 in culture medium for 24 h. JP-8 exposure resulted in significant expression differences (p<0.02) in 35 of the 929 proteins matched and analyzed. Approximately, a third of these alterations were increased in protein expression, two-thirds declined with JP-8 exposure. Peptide mass fingerprint identification of effected proteins revealed a variety of functional implications. In general, altered proteins involved endocytotic/exocytotic mechanisms and their cytoskeletal components, cell stress, and those involved in vesicular function.

  15. Fuel Composition Analysis of Endothermically Heated JP-8 Fuel for Use in a Pulse Detonation Engine

    Science.gov (United States)

    2008-06-01

    0.15 0.14 0.03 0.11 0.07 0.12 0.13 0.14 0.14 Methyl -cyclohexane * 3.38 0.13 0.25 0.30 0.37 0.38 0.18 0.31 0.26 0.31 0.28 0.32 0.33 Ethyl -cyclopentane...FUEL FOR USE IN A PULSE DETONATION ENGINE I. Introduction Motivation JP-8 is the predominant kerosene fuel currently used in the United States Air...Thermal Decomposition The fuel of choice for this research is JP-8 for many practical reasons. JP-8 is the predominant kerosene fuel currently used

  16. Reforming of JP-8 in Microplasmas for Compact SOFC Power 500 W

    Science.gov (United States)

    2012-11-30

    REPORT Final Report: Reforming of JP-8 in Microplasmas for Compact SOFC Power  W (W911NF0710118) 14. ABSTRACT 16. SECURITY CLASSIFICATION OF: The...Mar-2007 Standard Form 298 (Rev 8/98) Prescribed by ANSI Std. Z39.18 - 31-Jul-2010 Final Report: Reforming of JP-8 in Microplasmas for Compact SOFC ...for Compact SOFC Power,” Topical Symposium on Plasma Processing, AIChE Spring Meeting, Tampa, Florida, April 27, 2009. R.S. Besser, “Micro and

  17. Development of a Novel Noise Delivery System for JP-8 Ototoxicity Studies

    Science.gov (United States)

    2010-03-01

    methyl ethyl ketone were used in the plant, but numerous 9 additional solvents including trichloroethylene, acetone, n- methyl pyrrolidone...cyanide, diesel fuel, kerosene fuel, jet fuel, JP- 8 fuel, organophosphate pesticides, or chemical warfare nerve agents, where the exposure may result in

  18. Role of Volatility in the Development of JP-8 Surrogates for Diesel Engine Application

    Science.gov (United States)

    2014-01-01

    fuels have also been investigated in different types of experimental systems. Honnet [16] reported that the Aachen (n-decane/1,2,4-trimethylbenzene...indicated that the extinction characteristics of Aachen and modified Aachen (n-dodecane/1,2,4-trimethylbenzene) surrogate fuels agree well with JP-8 in

  19. BREATH MEASUREMENT OF TOTAL BODY BURDEN OF JP-8 JET FUEL FOR EPIDEMIOLOGICAL STUDY

    Science.gov (United States)

    A complex epidemiological investigation of the effects of acute exposure to JP-8 jet fuel in the U.S. Air Force was performed through the study of about 350 human subjects across six Air Force bases. The focus was on fuels system maintenance personnel as the "exposed"...

  20. Air impacts from three alternatives for producing JP-8 jet fuel.

    Science.gov (United States)

    Kositkanawuth, Ketwalee; Gangupomu, Roja Haritha; Sattler, Melanie L; Dennis, Brian H; MacDonnell, Frederick M; Billo, Richard; Priest, John W

    2012-10-01

    To increase U.S. petroleum energy independence, the University of Texas at Arlington (UT Arlington) has developed a direct coal liquefaction process which uses a hydrogenated solvent and a proprietary catalyst to convert lignite coal to crude oil. This sweet crude can be refined to form JP-8 military jet fuel, as well as other end products like gasoline and diesel. This paper presents an analysis of air pollutants resulting from using UT Arlington's liquefaction process to produce crude and then JP-8, compared with 2 alternative processes: conventional crude extraction and refining (CCER), and the Fischer-Tropsch process. For each of the 3 processes, air pollutant emissions through production of JP-8 fuel were considered, including emissions from upstream extraction/ production, transportation, and conversion/refining. Air pollutants from the direct liquefaction process were measured using a LandTEC GEM2000 Plus, Draeger color detector tubes, OhioLumex RA-915 Light Hg Analyzer, and SRI 8610 gas chromatograph with thermal conductivity detector. According to the screening analysis presented here, producing jet fuel from UT Arlington crude results in lower levels of pollutants compared to international conventional crude extraction/refining. Compared to US domestic CCER, the UTA process emits lower levels of CO2-e, NO(x), and Hg, and higher levels of CO and SO2. Emissions from the UT Arlington process for producing JP-8 are estimated to be lower than for the Fischer-Tropsch process for all pollutants, with the exception of CO2-e, which were high for the UT Arlington process due to nitrous oxide emissions from crude refining. When comparing emissions from conventional lignite combustion to produce electricity, versus UT Arlington coal liquefaction to make JP-8 and subsequent JP-8 transport, emissions from the UT Arlington process are estimated to be lower for all air pollutants, per MJ of power delivered to the end user. The United States currently imports two

  1. GEP 6.5LT Engine Cetane Window Evaluation for ATJ/JP-8 Fuel Blends

    Science.gov (United States)

    2015-09-01

    Engine Products H/C Hydrogen Atom to Carbon Atom Ratio HC Hydrocarbon HCCI Homogeneous Charge Compression Ignition HRJ8 Hydro Treated Renewable Jet...UNCLASSIFIED UNCLASSIFIED GEP 6.5LT ENGINE CETANE WINDOW EVALUATION FOR ATJ/JP-8 FUEL BLENDS INTERIM REPORT TFLRF No. 470 by...Destroy this report when no longer needed. Do not return it to the originator. UNCLASSIFIED UNCLASSIFIED GEP 6.5LT ENGINE CETANE WINDOW

  2. Preignition Chemistry of Xylenes and Their Effect on JP-8 Surrogates

    Science.gov (United States)

    2008-06-01

    The Effects of DTBP on the Oxidation of SI Primary Reference Fuels – A Study in an HCCI Engine and in a Pressurized Flow Reactor,” Ph.D. Thesis...blends with paraffins, and in JP-8 surrogates in a pressurized flow reactor, with complimentary experiments conducted in a single cylinder research engine ...Preignition Oxidation Chemistry of Xylene.” A tribute book for Professor Eliseo Ranzi, Italian Chemical Engineering Society, June 2008. 0.00Number of

  3. Investigation of Aerogel/Xerogel Catalysts for Autothermal Reforming of JP-8

    Science.gov (United States)

    2013-12-19

    supercritical conditions, where CO2 is typically used as the supercritical fluid. This conventional approach has proven to be costly as well as time...reforming catalysts for hydrogen production . Conversion of hydrocarbon fuels, such as gasoline, methanol , diesel, JP-8 and isobutanol by reforming is an...and Ar analysis (Carboxen 1000). The fractional conversion of n-Dodecane resulting from reforming (Xref) and the product yields of H2, CO, CO2 , and C1

  4. Autoignition and Combustion of JP-8 and its Surrogates at Moderate Pressures

    Science.gov (United States)

    2012-06-19

    shall be accomplished using a single kerosene -based fuel, in order of precedence: JP-8, commercial jet fuel (with additive package), or commercial jet...molecular weight esters and biodiesel. The fuels tested were methyl butanoate, methyl crotonate, ethyl propionate, biodiesel, and diesel. Two types...those for the methyl esters tested here. Critical conditions of extinction and ignition for methyl butanoate were calculated using a detailed chemical

  5. Analysis of rat testicular protein expression following 91-day exposure to JP-8 jet fuel vapor.

    Science.gov (United States)

    Witzmann, Frank A; Bobb, Andrew; Briggs, G Bruce; Coppage, Heather N; Hess, Rex A; Li, Junyu; Pedrick, Nathan M; Ritchie, Glenn D; Iii, John Rossi; Still, Kenneth R

    2003-06-01

    We analyzed protein expression in preparations from whole testis in adult male Sprague-Dawley rats exposed for 6 h/d for 91 consecutive days to jet propulsion fuel-8 (JP-8) in the vapor phase (0, 250, 500, or 1000 mg/m(3) +/- 10%), simulating a range of possible human occupational exposures. Whole body inhalation exposures were carefully controlled to eliminate aerosol phase, and subjects were sacrificed within 48 h postexposure. Organ fractions were solubilized and separated via large-scale, high resolution two-dimensional electrophoresis, and gel patterns scanned, digitized and processed for statistical analysis. Seventy-six different testis proteins were significantly increased or decreased in abundance in vapor-exposed groups, compared to controls, and dose-response profiles were often nonlinear. A number of the proteins were identified by peptide mass fingerprinting and related to histopathological or physiological deficits shown in previously published studies to occur with repeated exposure to hydrocarbon fuels or solvents. These results demonstrate a significant effect of JP-8 exposure on protein expression, particularly in protein expression in the rodent testis, and suggest that a 91 d exposure to jet fuel vapor induces changes of equal or greater magnitude to those reported previously for shorter duration JP-8 aerosol exposures.

  6. Direct Logistic Fuel JP-8 Conversion in a Liquid Tin Anode Solid Oxide Fuel Cell (LTA-SOFC)

    Science.gov (United States)

    2008-04-09

    demonstrated the ability of the Liquid Tin Anode Solid Oxide Fuel Cell (LTA SOFC) to direct convert logistic fuel, JP-8. The demonstration of direct JP-8...conversion without fuel processing or reforming was unprecedented in fuel cell technology. The DOD has a broad interest in power generation using

  7. Ignition length study of jp-8 + 100 in a supersonic duct

    Science.gov (United States)

    Bateup, M. L.

    2016-07-01

    In scramjets, hydrocarbon fuels are being considered for their endothermic potential and for use in flights where compact, volume critical designs are required at flight speeds at Mach 5+. Long-chain hydrocarbon (LCHC) fuels, like aviation kerosene, have handling and storage advantages over hazardous and volatile fuels, like hydrogen, that are more aligned with current flight systems. This research investigates the conditions under which kerosene fuel (JP-8 + 100) may be used in a supersonic duct at a hypervelocity impulse facility. Experimental data on kerosene ignition lengths for temperatures in the range 1100-1550 K, pressure of 1 atm, and equivalence ratios of 0.2-2.5 are compared with ignition delay correlations from literature.

  8. Evaluation of DSH/JP-8 Fuel Blends: Regarding its Effectiveness for Use in Ground Vehicles and Equipment

    Science.gov (United States)

    2016-10-31

    8 in diesel rotary fuel injection pumps at elevated temperature: • For elevated fuel inlet temperature operation, even with petroleum JP-8 at 77 °C...Lubricants Research Facility (TFLRF) located at Southwest Research Institute (SwRI), San Antonio, Texas , performed this work during the period...included basic chemical and physical property investigation to identify surrogate fuel sources with similar properties as traditional petroleum fuels

  9. U.S. Air Force Environmental Assessment: Repair by Replacement JP-8 Fuel Transfer Line Tinker Air Force Base, Oklahoma

    Science.gov (United States)

    2011-12-01

    Intergovernmental Coordination for Environmental Planning IRP Installation Restoration Program JP-8 Jet Propellant 8 JP-5 Jet Propellant 5 kPa kilo Pascal kW...headquarters of the Combat Control Center during the Cuban Missile Crisis. During the Vietnam War, the base’s size and responsibilities for aircraft and...Hazardous materials are defined as substances with physical properties of ignitability, corrosivity , reactivity, or toxicity that may cause an increase

  10. A Demonstration of HEFA SPK/JP-8 Fuel Blend at the Camp Grayling Joint Maneuver Training Center

    Science.gov (United States)

    2012-10-01

    Paraffinic Kerosene ( EFA SPK) and JP-8. The results from this demonstration will augment a significant set of evaluations already completed that indicate this... National Guard (MING) units operated a variety of tactical ground vehicles and other equipment they brought with them to Camp Grayling on the...the Army National Guard (ARNG) / Michigan National Guard (MING). TARDEC participation was spearheaded by the National Automotive Center (NAC) in

  11. Fuel Maps for the GEP 6.5LT Engine When Operating on at J/JP-8 Fuel Blends at Ambient and Elevated Temperatures

    Science.gov (United States)

    2015-04-01

    UNCLASSIFIED UNCLASSIFIED FUEL MAPS FOR THE GEP 6.5LT ENGINE WHEN OPERATING ON ATJ/JP-8 FUEL BLENDS AT AMBIENT AND ELEVATED TEMPERATURES...INTERIM REPORT TFLRF No. 464 By Douglas M. Yost Edwin A. Frame U.S. Army TARDEC Fuels and Lubricants Research Facility Southwest... FUEL MAPS FOR THE GEP 6.5LT ENGINE WHEN OPERATING ON ATJ/JP-8 FUEL BLENDS AT AMBIENT AND ELEVATED TEMPERATURES INTERIM REPORT TFLRF No. 464

  12. Conversion of a micro, glow-ignition, two-stroke engine from nitromethane-methanol blend fuel to military jet propellant (JP-8)

    Science.gov (United States)

    Wiegand, Andrew L.

    The goal of the thesis "Conversion of a Micro, Glow-Ignition, Two-Stroke Engine from Nitromethane-Methanol Blend Fuel to Military Jet Propellant (JP-8)" was to demonstrate the ability to operate a small engine on JP-8 and was completed in two phases. The first phase included choosing, developing a test stand for, and baseline testing a nitromethane-methanol-fueled engine. The chosen engine was an 11.5 cc, glow-ignition, two-stroke engine designed for remote-controlled helicopters. A micro engine test stand was developed to load and motor the engine. Instrumentation specific to the low flow rates and high speeds of the micro engine was developed and used to document engine behavior. The second phase included converting the engine to operate on JP-8, completing JP-8-fueled steady-state testing, and comparing the performance of the JP-8-fueled engine to the nitromethane-methanol-fueled engine. The conversion was accomplished through a novel crankcase heating method; by heating the crankcase for an extended period of time, a flammable fuel-air mixture was generated in the crankcase scavenged engine, which greatly improved starting times. To aid in starting and steady-state operation, yttrium-zirconia impregnated resin (i.e. ceramic coating) was applied to the combustion surfaces. This also improved the starting times of the JP-8-fueled engine and ultimately allowed for a 34-second starting time. Finally, the steady-state data from both the nitromethane-methanol and JP-8-fueled micro engine were compared. The JP-8-fueled engine showed signs of increased engine friction while having higher indicated fuel conversion efficiency and a higher overall system efficiency. The minimal ability of JP-8 to cool the engine via evaporative effects, however, created the necessity of increased cooling air flow. The conclusion reached was that JP-8-fueled micro engines could be viable in application, but not without additional research being conducted on combustion phenomenon and

  13. Determination of the Minimum Use Level of Fuel System Icing Inhibitor (FSII) in JP-8 That Will Provide Adquate Icing Inhibition and Biostatic Protection for Air Force Aircraft

    Science.gov (United States)

    2013-12-01

    of PFA-55MB)) in aviation kerosene . The advisory stated that data indicated that 0.015% by volume of FSII would prevent ice formation in fuel...and Anderson, S., “Investigation of the Anti-Microbial Characteristics of Di-Ethylene Glycol Mono Methyl Ether (DiEGME) in Relation to its Use...Detailed Specification, Turbine Fuel, Aviation, Kerosene Type, JP-8 (NATO F-34), NATO F-35, and JP-8+100 (NATO F-37),” released 14 September 2012. MIL

  14. Acute Dermal Irritation Study of Ten Jet Fuels in New Zealand White Rabbits: Comparison of Synthetic and Bio-Based Jet Fuels with Petroleum JP-8

    Science.gov (United States)

    2014-02-18

    kerosene, JP-8, biobased /bio-based, toxicity/toxicology 16. SECURITY CLASSIFICATION OF: U 17. LIMITATION OF ABSTRACT SAR 18. NUMBER OF PAGES 64...by a qualified technician upon receipt, weighed and uniquely identified by a plastic ear tag displaying the animal number. The rabbits were...of the animal was wrapped with plastic wrap to occlude the test site. The trunk of animals in both the occluded and semi-occluded groups was then

  15. Heating and Efficiency Comparison of a Fischer-Tropsch (FT) Fuel, JP-8+100, and Blends in a Three-Cup Combustor Sector

    Science.gov (United States)

    Thomas, Anna E.; Shouse, Dale T.; Neuroth, Craig; Lynch, Amy; Frayne, Charles W.; Stutrud, Jeffrey S.; Corporan, Edwin; Hankins, Terry; Saxena, Nikita T.; Hendricks, Robert C.

    2012-01-01

    In order to realize alternative fueling for military and commercial use, the industry has set forth guidelines that must be met by each fuel. These aviation fueling requirements are outlined in MIL-DTL-83133F(2008) or ASTM D 7566-Annex standards and are classified as drop-in fuel replacements. This paper provides combustor performance data for synthetic-paraffinic-kerosene- (SPK-) type (Fisher-Tropsch (FT)) fuel and blends with JP-8+100, relative to JP-8+100 as baseline fueling. Data were taken at various nominal inlet conditions: 75 psia (0.52 MPa) at 500 aF (533 K), 125 psia (0.86 MPa) at 625 aF (603 K), 175 psia (1.21 MPa) at 725 aF (658 K), and 225 psia (1.55 MPa) at 790 aF (694 K). Combustor performance analysis assessments were made for the change in flame temperatures, combustor efficiency, wall temperatures, and exhaust plane temperatures at 3%, 4%, and 5% combustor pressure drop (% P) for fuel:air ratios (F/A) ranging from 0.010 to 0.025. Significant general trends show lower liner temperatures and higher flame and combustor outlet temperatures with increases in FT fueling relative to JP-8+100 fueling. The latter affects both turbine efficiency and blade/vane life. In general, 100% SPK-FT fuel and blends with JP-8+100 produce less particulates and less smoke and have lower thermal impact on combustor hardware.

  16. Toxicokinetic Study for Investigation of Sex Differences in Internal Dosimetry of Jet Propulsion Fuel 8 (JP-8) in the Laboratory Rat

    Science.gov (United States)

    2013-07-26

    concentrations of JP-8 for 4 hrs Time (hr) Concentration in µg/L (ng/g) n- Octane 2- Methyl - octane 2,6-Dimethyl- octane n- Decane p-Ethyl- toluene n...2003. Biological and health ef- fects of exposure to kerosene -based jet fuels and performance additives. J Toxicol Environ Health B Crit Rev. 6:357...ml (Bottom of curve/MDL in ng/ml) n-Nonane 50/7.8 2,6-Di- methyl - octane 50/8.3 Toluene 10/7.8 o-Xylene 10/9.8 145 High/2 hour/Immediate 0.6

  17. A project of a two meter telescope in North Africa

    Science.gov (United States)

    Benkhaldoun, Zouhair

    2015-03-01

    Site testing undertaken during the last 20 years by Moroccan researchers through international studies have shown that the Atlas mountains in Morocco has potentialities similar to those sites which host the largest telescopes in world. Given the quality of the sites and opportunities to conduct modern research, we believe that the installation of a 2m diameter telescope will open new horizons for Astronomy in Morocco and north Africa allowing our region to enter definitively into the very exclusive club of countries possessing an instrument of that size. A state of the art astrophysical observatory on any good astronomical observation site should be equipped with a modern 2m-class, robotic telescope and some smaller telescopes. Our plan should be to operate one of the most efficient robotic 2m class telescopes worldwide in order to offer optimal scientific opportunities for researchers and maintain highest standards for the education of students. Beside all categories of astronomical research fields, students will have the possibility to be educated intensively on the design, manufacturing and operating of modern state of the art computer controlled instruments. In the frame of such education and observation studies several PhD and dissertational work packages are possible. Many of the observations will be published in articles worldwide and a number of guest observers from other countries will have the possibility to take part in collaborations. This could be a starting point of an international reputation of our region in the field of modern astronomy.

  18. Chronic effects of JP-8 jet-fuel exposure on the lungs. Annual report, 1 Apr 91-1 Apr 92

    Energy Technology Data Exchange (ETDEWEB)

    Witten, M.L.

    1992-04-23

    This research has resulted in four separate projects. The first was the exposure of Fischer 344 rats to JP-8 jet fuel for 7 or 28 days. This exposure resulted in changes in pulmonary function and lung chemical mediators, specifically Substance P, after 28 days of exposure. The second project dealt with blocking the increase in SP in these rats by a pretreatment regimen with capsaicin before jet fuel exposure. Capsaicin caused a further increase in lung permeability and a million-fold increase in airway sensitivity to histamine after the 7-day jet fuel exposure. The third project dealt with the effects of a 7-day jet fuel exposure in congenic mice who are deficient in the inducibility of the aryl hydrocarbon hydroxylase enzyme. These mice are relatively resistant to the effects of jet fuel-induced lung injury. The fourth project investigated the effects of the jet fuel exposure on secondary organs, specifically the liver, spleen, and kidneys. There were pathological differences in the liver, spleen, and kidneys between the 7-day jet fuel exposure group and baseline controls. However, some of these differences were not apparent in the 28-day exposure group, possibly indicating compensatory mechanisms to the exposure.

  19. Durability Evaluation of the Effects of Hydro-processed Renewable Jet (HRJ) Blended at 50% with Petroleum JP-8 on a Navistar Maxxforce D10 9.3L Engine

    Science.gov (United States)

    2012-05-01

    nif old C oo lan t En gin e I n Co ola nt En gin e Ou t...100 hour JP-8 Performance Run, Standard and DOC Data Summary UNCLASSIFIED A3 - 3 JP -8 10 0 H RS Ai r L FE Int ak e Ma nif old C AC De...CA C I nle t C AC ou tle t Int ak e Ma nif old C oo lan t En gin e I n Co ola nt En gin e Ou t Oi l S um p Te mp Fu el Be ak er Fu el

  20. JP-8 and Other Military Fuels

    Science.gov (United States)

    2011-12-01

    Army systems. Unclassified Military Fuel Additives Unclassified • Antioxidants (AO) - Required in fuels that have hydrotreated components...Deoxygenation & Hydrotreating Selective Hydrocracking Product Separationtallow fats wood waste & by-products agri-wastenon-food crops algae

  1. Modeling of Complex Mixtures: JP-8 Toxicokinetics

    Science.gov (United States)

    2008-10-01

    diffusion, including metabolic loss via the cytochrome P-450 system, described by non-linear Michaelis - Menten kinetics as shown in the following...point. Inhalation and iv were the dose routes for the rat study. The modelers used saturable ( Michaelis - Menten ) kinetics as well as a second... Michaelis - Menten liver metabolic constants for n-decane have been measured (Km = 1.5 mg/L and Vmax = 0.4 mg/hour) using rat liver slices in a vial

  2. Conversion of Small Algal Oil Sample to JP-8

    Science.gov (United States)

    2012-01-01

    cracked iso-alkane fraction into a naphtha cut (approx. initial boiling point to 150°C) and a Jet cut (approx 150°C to 260°C). W911NF-10-C-0021 Page 1...because over cracking will result in low yields to jet range paraffins and high yields of light ends (C l- C4) and naphtha (C5-C8), both outside the...cracking step a second time. This avoided the over cracking of that material that was already in the jet range to Naphtha during a second pass and only

  3. JP-8 and Other Military Fuels (2014 UPDATE)

    Science.gov (United States)

    2014-06-17

    carbon-neutral output – Must be processed using FT or HEFA process. – Example: Algal biofuels 4th G i Al i F l ?? UNCLASSIFIED: Distribution Statement A...1st Generation Alternative Fuels – Largely made from edible sugars, starches, animal fats and vegetable oils – Food based crops – Examples...Biodiesel, Ethanol – Not cost competitive with fossil fuels • 2nd Generation Alternative Fuels – Fischer-Tropsch Synthetic Paraffinic Kerosene (FT-SPK) and

  4. Investigation of JP-8 Autoignition Under Vitiated Combustion Conditions

    Science.gov (United States)

    2011-01-01

    combustion engines and HCCI systems rather than low pressure combustion devices that are of interest in the current study. This data provides insight...2011 Directed by: Professor Gregory Jackson, Chair Department of Mechanical Engineering Limited data on jet fuel ignition and oxidation at...Fuller 2011 ii Acknowledgements This research has been supported and funded by Combustion Science and Engineering , Inc. through the following

  5. Catalytic Partial Oxidation Reforming of JP8 AND S8

    Science.gov (United States)

    2007-06-01

    magnesium oxide (MgO) and have temperatures above 500°C. A kinetics study of steam reformation of isooctane has been performed. Temperatures at the end...been used and are better than nickel based catalysts (Shekawat et al., 2006). A study conducted with isooctane using CPOX reforming showed coking

  6. Immune Suppression by Dermal Application of JP-8 Jet Fuel

    Science.gov (United States)

    2008-10-13

    transmitting the immunosuppressive signal from the skin to the immune system ( Limon -Flores, et al., Mast Cells mediate the Immune suppression Induced by...human and murine data. Nat Rev Immunol 7, 93-104. Byrne, S. N., Limon -Flores, A. Y. and Ullrich, S. E. (2008). Mast cell migration from the skin to...Ramos, G., Limon -Flores, A. Y. and Ullrich, S. E. (2007). Dermal exposure to jet fuel suppresses delayed-type hypersensitivity: a critical role

  7. JP-8 and JP-5 as Compression Ignition Engine Fuel

    Science.gov (United States)

    1985-01-15

    PROGRAM MANAGER, BRADELY FIGHTING VEHICLE SYS HQ, EUROPEAN COMMAND ATTN: AMCPM-FVS-M I ATTN: J4/7-LJPO (LTC LETTERIE) . WARREN MI 4Z€90 VAIHINGEN, GE...LEE VA 23801 HQ, US ARMY ARMOR• CENTER AND DAVID TAYLOR NAVAL SHIP R&D CTR FORT KNOX ATTN: CODE 2830 (MR G BOSMAJIAN) I ATTN: ATSB-CD I CODE 2759 (MR

  8. Surfactant Enhanced Microbial Degradation of JP-8 Contaminated Soil

    Science.gov (United States)

    1996-12-01

    Aromatics Xylenes Polycyclic Aromatics n-Alkanes Alkylbenzenes PAHs n-Alkenes Nitro-substituted Aromatics PNAs Phenols Halogenated Aliphatics Cycloalkanes...solubility has an apparent linear increase (Rosen, 1989:171). Solubilization occurs at a number of sites within a micelle (Figure 2.6): (1) the inner... Sulfonate (anionic). Each of these surfactants showed enhancement of biodegradation close to 90%, when compared to treatments without surfactant addition

  9. Interpreting stem diameter changes

    Science.gov (United States)

    Hölttä, T.; Sevanto, S.; Nikinmaa, E.

    2009-12-01

    Detecting phloem transport in stem diameter changes Teemu Hölttä1, Sanna Sevanto2, Eero Nikinmaa1 1Department of Forest Ecology, P.O. Box 27, FIN-00014 University of Helsinki, Finland 2Department of Physics, P.O. Box 48, FIN-00014 University of Helsinki, Finland Introduction The volume of living cells and xylem conduits vary according to pressures they are subjected to. Our proposition is that the behavior of the inner bark diameter variation which cannot be explained by changes in xylem water status arise from changes in the osmotic concentration of the phloem and cambial growth. Materials and methods Simultaneous xylem and stem diameter measurements were conducted between June 28th to October 4th 2006 in Southern Finland on a 47-year old, 15 meter tall, Scots pine tree (DBH 15 cm) at heights of 1.5 and 10 meters. The difference between the measured inner bark diameter and the inner bark diameter predicted from xylem diameter change with a simple model (assuming there was no change in the osmotic concentration of the phloem) is hypothesized to give the changes in the osmotic concentration of the inner bark. The simple model calculates the radial water exchange between the xylem and phloem driven by the water potential changes in the xylem. Results and Discussion The major signal in the inner bark diameter was the transpiration rate as assumed, but also a signal arising from the change in the osmotic concentration (Fig 1a). The predicted osmotic concentration of the phloem typically increased during the afternoon due to the loading of photosynthesized sugars to the phloem. Inner bark osmotic concentration followed the photosynthesis rate with a 3 and 4 hour time-lag at the top and base, respectively (Fig 1b). The connection between photosynthesis and the predicted change in phloem osmotic concentration was stronger in the upper part of the tree compared to lower part. The changes in the predicted osmotic concentration were not similar every day, indicating that

  10. Double diameter boring tool

    Science.gov (United States)

    Ashbaugh, Fred N.; Murry, Kenneth R.

    1988-12-27

    A boring tool and a method of operation are provided for boring two concentric holes of precision diameters and depths in a single operation. The boring tool includes an elongated tool body, a shank for attachment to a standard adjustable boring head which is used on a manual or numerical control milling machine and first and second diametrically opposed cutting edges formed for cutting in opposite directions. The diameter of the elongated tool body is substantially equal to the distance from the first cutting edge tip to the axis of rotation plus the distance from the second cutting edge tip to the axis of rotation. The axis of rotation of the tool is spaced from the tool centerline a distance substantially equal to one-half the distance from the second cutting edge tip to the axis of rotation minus one-half the distance from the first cutting edge tip to the axis of rotation. The method includes the step of inserting the boring tool into the boring head, adjusting the distance between the tool centerline and the tool axis of rotation as described above and boring the two concentric holes.

  11. Small diameter carbon nanopipettes

    Science.gov (United States)

    Singhal, Riju; Bhattacharyya, Sayan; Orynbayeva, Zulfiya; Vitol, Elina; Friedman, Gary; Gogotsi, Yury

    2010-01-01

    Nanoscale multifunctional carbon probes facilitate cellular studies due to their small size, which makes it possible to interrogate organelles within living cells in a minimally invasive fashion. However, connecting nanotubes to macroscopic devices and constructing an integrated system for the purpose of fluid and electrical signal transfer is challenging, as is often the case with nanoscale components. We describe a non-catalytic chemical vapor deposition based method for batch fabrication of integrated multifunctional carbon nanopipettes (CNPs) with tip diameters much smaller (10-30 nm) than previously reported (200 nm and above) and approaching those observed for multiwalled carbon nanotubes. This eliminates the need for complicated attachment/assembly of nanotubes into nanofluidic devices. Variable tip geometries and structures were obtained by controlled deposition of carbon inside and outside quartz pipettes. We have shown that the capillary length and gas flow rate have a marked effect on the carbon deposition. This gives us a flexible protocol, useful for growing carbon layers of different thicknesses at selective locations on a glass pipette to yield a large variety of cellular probes in bulk quantities. The CNPs possess an open channel for fluid transfer with the carbon deposited inside at 875 °C behaving like an amorphous semiconductor. Vacuum annealing of the CNP tips at temperatures up to 2000 °C yields graphitic carbon structures with an increase in conductivity of two orders of magnitude. Penetration of the integrated carbon nanoprobes into cells was shown to produce minimal Ca2+ signals, fast recovery of basal Ca2+ levels and no adverse activation of the cellular metabolism during interrogation times as long as 0.5-1 h.

  12. Diameters of Triton and Pluto

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, D.; Cruikshank, D.P. (Hawaii Univ., Honolulu (USA). Inst. for Astronomy); Brown, R.H. (Hawaii Univ., Honolulu (USA). Dept. of Physics and Astronomy; Hawaii Univ., Honolulu (USA). Hawaii Inst. of Geophysics)

    1982-12-02

    Upper limits are reported to the thermal IR emission from Triton, the major satellite of Neptune, and Pluto, the outermost planet, that permit significant upper limits to be set on their diameters and also demonstrate that both are high albedo objects. These results exclude the possibility that Triton is the largest planetary satellite and are consistent with the small size of Pluto deduced from other data.

  13. Combustion of High Molecular Weight Hydrocarbon Fuels and JP-8 at Moderate Pressures

    Science.gov (United States)

    2016-07-26

    corresponding results for methane, ethane, and ethylene , were obtained as well the effects of different reaction rates on comparisons between... ethylene , as well as showing the effects of different reaction rates on comparisons between predictions and measurements for all of the fuels tested. There...displacement effects imply that however an oxidizer -side strain rate may be defined, any correct value will be significantly greater than could be

  14. Fire Safety Tests Comparing Synthetic Jet and Diesel Fuels with JP-8 (POSTPRINT)

    Science.gov (United States)

    2010-04-01

    extinguishment and burnback time for experimental test fires using AFFF on unleaded gasoline. The test fire standards outlined in the mil-spec are more...natural gas , followed by a Fischer–Tropsch process using a low-temperature cobalt catalyst to obtain 499% saturated (mainly n- or iso-paraffin) hydrocarbons...natural gas followed by a Fischer–Tropsch process, but different refining is used to obtain the desired fuel composition with an average molecular

  15. Adsorptive Desulfurization of JP-8 Fuel Using Ag+/Silica Based Adsorbents at Room Temperature

    Science.gov (United States)

    2012-09-01

    cell-quality hydrogen is liquid phase desulfurization (figure 1). Any organic sulfur compounds in the fuel are converted into hydrogen sulfide in...the fuel processing reformer, resulting in poisoning the reformation catalysts as well as poisoning downstream operations. Therefore, it is essential...the reformation catalysts from potential poisoning (1). Figure 1. Schematic diagram of logistic fuel processing. Adsorbents with a high

  16. Military Requirements for JP-8 Reformers and Solid Oxide Fuel Cell Power Systems

    Science.gov (United States)

    2005-12-01

    agreement between the Purchasing Authority and the supplier. The inhibitor shall be composed entirely of diethylene glycol mono- methyl ether except that...occur. 2. Federal Specification A-A-52624 – Antifreeze, Multi Engine Type This CID covers the requirements for ethylene glycol -based and propylene ...percentage listed): • 2-Napthalenol [(Phenylazo) phenyl ]-Azo Alkyl Derivatives • Benzene • Ethyl Benzene • Other absorbent materials. Ground Fuel

  17. Branch Detonation of a Pulse Detonation Engine With Flash Vaporized JP-8

    Science.gov (United States)

    2006-12-01

    head with dual overhead camshafts . Four intake/exhaust valves control the amount of fuel-air mixture into the engine. Up to four thrust tubes can be...The valves are controlled by the camshafts that are in turn driven by a variable speed Baldor Electrical motor (Model# M4102T). Within each...position of the camshaft and sends it to the control room. The computer then translates that information to valve position. When both valves are

  18. Pulse Detonation Engine Thrust Tube Heat Exchanger for Flash Vaporization and Supercritical Heating of JP-8

    Science.gov (United States)

    2005-03-01

    position of the camshaft in the PDE. The camshaft position is read by a BEI optical encoder (Model H25, S/N 44 Y0013039) and sent to the...research uses the head from a General Motors Quad 4 head with dual overhead camshafts shown in Figure 19. The camshafts are belt driven by a

  19. Fire Extinguishing Performance of Firebane on JP-8 Jet Fuel Fires

    Science.gov (United States)

    2012-04-17

    Compressed Air Foam CAFFS Combined Agent Fire Fighting System cm3 cubic centimeter ft2 square feet g grams gal/min gallons per minute GSL Global...agent used, and effectiveness on the fires . Compressed air foam systems were used for the evaluations, the recommended agent delivery method for...the engine protocol pool fire ....................................... 14 Figure 6. Firebane 1115 foam blanket during engine nacelle test

  20. Production of JP-8-Based Hydrogen and Advanced Tactical Fuels for the U.S. Military

    Science.gov (United States)

    2009-09-24

    arranged in the form of a thin wafer or disc" ( Fogler , 1999). Because the HDO catalyst comes in pellet form, a wafer was not used in these experiments...respectively ( Fogler , 1999). Flow Flow Rate - Rate + In Out Rate of Generation Rate of Accumulation Eq. 1 [FAO]-[FJ+ ( Rate _of _ Re...securing no-cost project extensions, securing cost-share funding, and other such project and contract modifications. REFERENCES Fogler , S.H

  1. Laboratory Evaluation of MIL-T-83133 JP-8 Fuel in Army Diesel Engines

    Science.gov (United States)

    1988-01-01

    Combustion, Stu/lb 18,279 (b) (a) ’J/kg 42,516 (b) (a) Catane Number 52 51 45-5L Cetane Index 47 47 (a) Carbon, vtl 86.24 -- (a) Hydrogen, vtl 12.19...a) XJ/kg 42,516 (b) (a) Cetae Number 52 51 45-51 Catane Index 47 47 (a) Carbon, wt% 86.24 -- (a) Hydrogen, wt% 12.19 -- (a) Sulfur, wt 0.41 0.40

  2. Acute Dermal Irritation Study of JP-8 and S-8 in New Zealand White Rabbits

    Science.gov (United States)

    2011-01-01

    deemed appropriate by the veterinary staff and Study Director. The Sponsor will be advised by the Study Director of all circumstances which could lead...to this action in as timely a manner as possible.  Methods of euthanasia used during this study are in conformance with the above- referenced

  3. Inhalation Exposure to Jet Fuel (JP8) Among U.S. Air Force Personnel

    Science.gov (United States)

    2010-10-01

    REPORT DOCUMENTATION PAGE Form Approved OMS No 0704-0133 , ~~~~~¥~~~E;~ 2. REPORT IT!’!:. "" .. ’ "’~ - "I 14-09-2010 lournal Anicle...per year.O) Due 10 the widespread use of lP8 and similar jct fuels in the military and commercial airline industry. over 2 million people per year

  4. Toxicity Assessment of F-T Jet Fuel (JP-8/SPK)

    Science.gov (United States)

    2009-05-01

    findings in the noses of male rats (ten per group) Olfactory Epithelial Hypertrophy Hyperplasia Goblet Cells Group De_generation Nasopharng_eal Duct...Olfactory Epithelial Hypertrophy Hyperplasia Goblet Cells Degeneration Nasopharngeal Duct Control 0 0 Low 0 0 Intermediate 8 9 High 10 10

  5. Evaluation of Barrier Skin Cream Effectiveness Against JP-8 Jet Fuel Absorption and Irritation

    Science.gov (United States)

    2009-04-01

    trichromatic color matching of spectral lights, which is a function of their wavelengths from 380 to 780 nm ( Broadbent , 2004). METHODS...sufficient protection provided by candidate barrier creams in the animal model. REFERENCES Broadbent , A. D. "A critical review of the

  6. Feasibility of JP-8 to Jet a Fuel Conversion at U.S. Military Facilities

    Science.gov (United States)

    2008-03-01

    Denoted in contract) BUP Base Unit Price (Denoted in contract) Equations Acronyms Item/Mode Award Prices Base Mkt Price Differential 0101/TK Fairchild...Denoted in contract) Equations Acronyms Item/Mode Award Prices Base Mkt Price Initial Differential 0101/TT (Ft Lewis & Yakima) 1.857217 1.847317

  7. Progress in the Production of JP-8 Based Hydrogen and Advanced Tactical Fuels for Military Applications

    Science.gov (United States)

    2011-02-01

    fatty acids, coconut oil , palm oil , yellow grease, fatty acids from animal fats, and various algal oils . Feedstock flex- ibility is a major process...projections reflect continued high crude oil prices and increased demand for biofuels , particularly in the United States and the European Union. Note...20314-1000 Under Project Requisition No. 137573 ERDC/CERL TR-11-2 ii Abstract: Today’s Army is heavily dependent on oil and its byproducts as

  8. Experimental and Theoretical Studies of Autoignition and Burning Speed of JP8 and DF-2

    Science.gov (United States)

    2008-10-20

    Isooctane and Indolence at High Pressure and Temperature." Combustion and Flame 48: 191-210, 1982. [3] Elia, M., Moore,P., Ulinski, M., and Metghalchi...34Burning Velocities of Mixtures of Air with Methanol, Isooctane and Indolence at High Pressure and Temperature." Combustion and Flame 48: 191-210

  9. Simulation of Dual Firing of Hydrogen and JP-8 in a Swirling Combustor

    Science.gov (United States)

    2012-06-14

    includes loads such as laptop computers, radios, power tools, and battery chargers. This need opens the door for Stirling engines ...collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE 14 JUN 2012 2. REPORT TYPE Conference Paper...7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) U.S. ARMY COMMUNICATIONS-ELECTRONICS RESEARCH DEVELOPMENT AND ENGINEERING CENTER,5100 Magazine Rd

  10. Use of Respirometry To Determine the Effect of Nutrient Enhancement on JP-8 Biodegradability.

    Science.gov (United States)

    2007-11-02

    Medium Eliminates Potential Long Term Liability Attractive Economics Can Be Coupled with other Treatment Technologies Minimal Exposure to On-Site...Fluid Medium. United States Patent No. 4,947,339. August 7, 1990. Dean-Ross, Deborah, Howard Mayfield, and Jim Spain. " Enviromental Fate and

  11. Quantitating the Absorption, Partitioning and Toxicity of Hydrocarbon Components of JP-8 Jet Fuel

    Science.gov (United States)

    2007-08-24

    Epidermis hi Vitro In Vi, FTIR abscess Thickness Thickness Cytotoxicity IL-8 _____Iday 4day ( pt da i) 4day 24 h 241It Undecane + - - ++ 56 64 75...absorption studies with programmed thermal treatment and FTIR microscopy. Anal . Chem. 76: 4245-4250, 2004. 8 6. Xia XR, Baynes RE, Monteiro-Riviere NA, Riviere

  12. The Carcinogenic Potential of JP-8 and Tungsten in C57BL/6 Mice

    Science.gov (United States)

    2011-01-31

    progressive anemia ), neutrophilia (not significant due to small n-values), and splenomegaly (p=0.0406, 0.0184, 0.0108 for C, W and RSV, respectively...drawn and analyzed for alterations that include anemia and neutrophilia. After 6 months animals have been sacrificed and spleens have been excised to...sequences in neonatal blood spots, Proc Natl Acad Sci U S A 94(25) (1997) 13950-13954. 3. J.L. Wiemels, Z. Xiao, P.A. Buffler, A.T. Maia, X. Ma

  13. Environmental Baseline Survey for JP-8 Pipeline Route Nellis Air Force Base Las Vegas, Nevada

    Science.gov (United States)

    2005-01-01

    Nellis AFB Monitoring well location and IRP site status Jim Pedrick Site inspection, IRP site status (702) 652-6103 Chief, Engineering, 99th CES/CEV...Manager 5 ST-27 trailer in Area III 644-7630 Bernd Schmidt IRP Manager 3 Nellis AFB EM 652-2882 Jim Pedrick EM Manager 5 Nellis AFB EM 652-6103...Contact Name Title Years Associated with Building Shop Name Telephone Number Bernd Schmidt IRP Manager 3 Nellis AFB EM 652-2882 Jim Pedrick EM Manager 5

  14. The truth about laser fiber diameters.

    Science.gov (United States)

    Kronenberg, Peter; Traxer, Olivier

    2014-12-01

    To measure the various diameters of laser fibers from various manufacturers and compare them with the advertised diameter. Fourteen different unused laser fibers from 6 leading manufacturers with advertised diameters of 200, 270, 272, 273, 365, and 400 μm were measured by light microscopy. The outer diameter (including the fiber coating, cladding, and core), cladding diameter (including the cladding and the fiber core), and core diameter were measured. Industry representatives of the manufacturers were interviewed about the diameter of their fibers. For all fibers, the outer and cladding diameters differed significantly from the advertised diameter (P cladding, and core diameters of fibers with equivalent advertised diameters differed by up to 180, 100, and 78 μm, respectively. Some 200-μm fibers had larger outer diameters than the 270- to 273-μm fibers. All packaging material and all laser fibers lacked clear and precise fiber diameter information labels. Of 12 representatives interviewed, 8, 3, and 1 considered the advertised diameter to be the outer, the cladding, and the core diameter, respectively. Representatives within the same company frequently gave different answers. This study suggests that, at present, there is a lack of uniformity between laser fiber manufacturers, and most of the information conveyed to urologists regarding laser fiber diameter may be incorrect. Because fibers larger than the advertised laser fibers are known to influence key interventional parameters, this misinformation can have surgical repercussions. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. MWD tool for deep, small diameter boreholes

    Energy Technology Data Exchange (ETDEWEB)

    Buytaert, J.P.R.; Duckworth, A.

    1992-03-17

    This patent describes an apparatus for measuring a drilling parameters while drilling a borehole in an earth formation, wherein the borehole includes a small diameter deep borehole portion and a large diameter upper borehole portion. It includes small diameter drillstring means for drilling the deep borehole portion; sensor means, disposed within the small diameter drillstring means, for measuring a drilling parameter characteristic of the deep portion of the borehole while drilling the deep portion of the borehole and for providing sensor output signals indicative of the measured parameter; an upper drillstring portion extending between the surface of the formation and the small diameter drillstring means, the upper drillstring portion including a large diameter drillstring portion; data transmission means disposed within the large diameter drillstring portion and responsive to the sensor output.

  16. 7 CFR 51.2850 - Diameter.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946... Diameter. Diameter means the greatest dimension measured at right angles to a straight line running from...

  17. 7 CFR 51.712 - Diameter.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946... § 51.712 Diameter. Diameter means the greatest dimension measured at right angles to a line from stem...

  18. 7 CFR 51.651 - Diameter.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946...) Definitions § 51.651 Diameter. Diameter means the greatest dimension measured at right angles to a line from...

  19. Measuring angular diameters of extended sources

    NARCIS (Netherlands)

    van Hoof, PAM

    2000-01-01

    When measuring diameters of partially resolved sources like planetary nebulae, H II regions or galaxies, often a technique called Gaussian deconvolution is used. This technique yields a Gaussian diameter, which subsequently has to be multiplied by a conversion factor to obtain the true angular

  20. Impact Structures: What Does Crater Diameter Mean?

    Science.gov (United States)

    Turtle, E. P.; Pierazzo, E.; Collins, G. S.; Osinski, G. R.; Melosh, H. J.; Morgan, J. V.; Reimold, W. U.; Spray, J. G.

    2004-03-01

    Crater diameter is an important parameter in energy scaling and impact simulations. However, disparate types of data make the use of consistent metrics difficult. We suggest a consistent terminology and discuss it in the context of several examples.

  1. Defining a Minimum End Mill Diameter

    Directory of Open Access Journals (Sweden)

    A. E. Dreval'

    2015-01-01

    Full Text Available Industrial observations show that the standard mill designs in many cases do not provide a complete diversity of manufacturing operations, and a lot of enterprises are forced to design and manufacture special (original designs of tools. The information search has revealed a lack of end mill diameter calculations in publications. There is a proposal to calculate the end mill diameter either by empirical formulas [2, 3], or by selection from the tables [4].To estimate a minimum diameter of the end mill to perform the specified manufacturing operations based on the mill body strength the formulas are obtained. The initial data for calculation are the flow sheet of milling operation and properties of processed and tool materials. The end mill is regarded, as a cantilevered beam of the circular cross section having Dс diameter (mill core diameter with overhang Lв from rigid fixing and loaded by the maximum bending force and torque.In deriving the formulas were used the following well-reasoned assumptions based on the analysed sizes of the structural elements of the standard mills: a diameter of mill core is linearly dependent on the mill diameter and the overhang; the 4τ 2 to σ 2 4τ2 ratio is constant and equal to 0.065 for contour milling and 0.17 for slot milling.The formulas for calculating the minimum diameter are as follows:  3 обр в 1 121 1.1  K S L L D m C z    for contour milling;  3 обр в 1 207 1.1  K S L L D m C z    for slot milling.Obtained dependences that allow defining a minimum diameter of the end mill in terms of ensuring its strength can be used to design mills for contour milling with radius transition sections, holes of different diameters in the body parts and other cases when for processing a singlemill is preferable.Using the proposed dependencies for calculating a feed of the maximum tolerable strength is reasonable in designing the mills for slots.Assumptions used in deriving

  2. Unit distances and diameters in Euclidean spaces

    CERN Document Server

    Swanepoel, Konrad J

    2007-01-01

    We show that the maximum number of unit distances or of diameters in a set of n points in d-dimensional Euclidean space is attained only by specific types of Lenz constructions, for all d >= 4 and n sufficiently large, depending on d. As a corollary we determine the exact maximum number of unit distances for all even d >= 6, and the exact maximum number of diameters for all d >= 4, for all $n$ sufficiently large, depending on d.

  3. Shaft Diameter Measurement Using Structured Light Vision

    OpenAIRE

    2015-01-01

    A method for measuring shaft diameters is presented using structured light vision measurement. After calibrating a model of the structured light measurement, a virtual plane is established perpendicular to the measured shaft axis and the image of the light stripe on the shaft is projected to the virtual plane. On the virtual plane, the center of the measured shaft is determined by fitting the projected image under the geometrical constraints of the light stripe, and the shaft diameter is meas...

  4. Appendiceal diameter: CT versus sonographic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Orscheln, Emily S. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati, OH (United States); Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-03-15

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  5. Collagen fibril diameter and leather strength.

    Science.gov (United States)

    Wells, Hannah C; Edmonds, Richard L; Kirby, Nigel; Hawley, Adrian; Mudie, Stephen T; Haverkamp, Richard G

    2013-11-27

    The main structural component of leather and skin is type I collagen in the form of strong fibrils. Strength is an important property of leather, and the way in which collagen contributes to the strength is not fully understood. Synchrotron-based small angle X-ray scattering (SAXS) is used to measure the collagen fibril diameter of leather from a range of animals, including sheep and cattle, that had a range of tear strengths. SAXS data were fit to a cylinder model. The collagen fibril diameter and tear strength were found to be correlated in bovine leather (r(2) = 0.59; P = 0.009), with stronger leather having thicker fibrils. There was no correlation between orientation index, i.e., fibril alignment, and fibril diameter for this data set. Ovine leather showed no correlation between tear strength and fibril diameter, nor was there a correlation across a selection of other animal leathers. The findings presented here suggest that there may be a different structural motif in skin compared with tendon, particularly ovine skin or leather, in which the diameter of the individual fibrils contributes less to strength than fibril alignment does.

  6. Diameter Preserving Surjection on Alternate Matrices

    Institute of Scientific and Technical Information of China (English)

    Li Ping HUANG

    2009-01-01

    Let F be a field with |F| ≥ 3, Km be the set of all m × m (m ≥ 4) alternate matrices over F. The arithmetic distance of A, B ∈ Km is d(A, B) := rank(A- B). If d(A, B) = 2, then A and B are said to be adjacent. The diameter of Km is max{d(A, B) : A, B ∈ Km}. Assume that ψ : Km→ Km is a map. We prove the following are equivalent: (a) ψ is a diameter preserving surjection in both directions, (b) ψ is both an adjacency preserving surjection and a diameter preserving map, (c) ψ is a bijective map which preserves the arithmetic distance.

  7. The truth about small-diameter implants.

    Science.gov (United States)

    Christensen, Gordon J; Child, Paul L

    2010-05-01

    SDIs that are treatment planned correctly, placed and loaded properly, and are within a well-adjusted occlusion, are working in an excellent manner for the patients described in this article. It is time for those practitioners unfamiliar with SDIs and their uses to discontinue their discouragement of this technique. SDIs are easily placed, minimally invasive, and a true service to those patients described. They do not replace conventional diameter implants; however, they are a significant and important augmentation to the original root-form implant concept. There is obvious evidence of the growing acceptance of small-diameter implants by both general practitioners and specialists.

  8. THERMAL EVALUATION OF DIFFERENT DRIFT DIAMETER SIZES

    Energy Technology Data Exchange (ETDEWEB)

    H.M. Wade

    1999-01-04

    The purpose of this calculation is to estimate the thermal response of a repository-emplaced waste package and its corresponding drift wall surface temperature with different drift diameters. The case examined is that of a 21 pressurized water reactor (PWR) uncanistered fuel (UCF) waste package loaded with design basis spent nuclear fuel assemblies. This calculation evaluates a 3.5 meter to 6.5 meter drift diameter range in increments of 1.0 meters. The time-dependent temperatures of interest, as determined by this calculation, are the spent nuclear fuel cladding temperature, the waste package surface temperature, and the drift wall surface temperature.

  9. Shaft Diameter Measurement Using Structured Light Vision.

    Science.gov (United States)

    Liu, Siyuan; Tan, Qingchang; Zhang, Yachao

    2015-08-12

    A method for measuring shaft diameters is presented using structured light vision measurement. After calibrating a model of the structured light measurement, a virtual plane is established perpendicular to the measured shaft axis and the image of the light stripe on the shaft is projected to the virtual plane. On the virtual plane, the center of the measured shaft is determined by fitting the projected image under the geometrical constraints of the light stripe, and the shaft diameter is measured by the determined center and the projected image. Experiments evaluated the measuring accuracy of the method and the effects of some factors on the measurement are analyzed.

  10. Shaft Diameter Measurement Using Structured Light Vision

    Directory of Open Access Journals (Sweden)

    Siyuan Liu

    2015-08-01

    Full Text Available A method for measuring shaft diameters is presented using structured light vision measurement. After calibrating a model of the structured light measurement, a virtual plane is established perpendicular to the measured shaft axis and the image of the light stripe on the shaft is projected to the virtual plane. On the virtual plane, the center of the measured shaft is determined by fitting the projected image under the geometrical constraints of the light stripe, and the shaft diameter is measured by the determined center and the projected image. Experiments evaluated the measuring accuracy of the method and the effects of some factors on the measurement are analyzed.

  11. Influence of tube's diameter on boiling heat transfer performance in small diameter tubes

    Science.gov (United States)

    Gan, Chengjun; Wang, Weicheng; Zhang, Lining

    1998-03-01

    This paper reports the experiments of evaporation study in 6 mm inner copper diameter tubes using HFC-134a, HCFC-22 and CFC-12 as working fluid. The results show that the evaporation heat transfer coefficient increases with the decreasing of inner diameter of tubes. A new concept of non-dimensional tube diameter U is proposed in this paper for correction of the influence of the tube diameter on the evaporation heat transfer coefficient. And further, a convenient empirical correction method is presented.

  12. Influence of Tube‘s Diameter on Boling Heat Transfer Performance in Small Diameter Tubes

    Institute of Scientific and Technical Information of China (English)

    GanChengjun; WangWeicheng; 等

    1998-01-01

    This paper reports the experiments of evaporation study in 6 mm inner copper diameter tubes using HFC-134a,HCFC-22 and CFC-12 as working fluid.The results show that the evaporation heat transfer cofeeicient increasese with the decreasing of inner diameter of tubes,A new concept of nondimensional tube diameter U is proposed in this paper for correction of the influence of the tube diameter on the evaporation heat transfer coefficient.And further,a conveinent empirical correction method is preseted.

  13. Numerical Analysis of Large Diameter Butterfly Valve

    Science.gov (United States)

    Youngchul, Park; Xueguan, Song

    In this paper, a butterfly valve with the diameter of 1,800 mm was studied. Three-dimensional numerical technique by using commercial code CFX were conducted to observe the flow patterns and to measure flow coefficient, hydrodynamic torque coefficient and so on, when the large butterfly valve operated with various angles and uniform incoming velocity.

  14. Photoacoustic determination of blood vessel diameter.

    NARCIS (Netherlands)

    Kolkman, R.G.; Klaessens, J.H.G.M.; Hondebrink, E.; Hopman, J.C.W.; Mul, F.F. de; Steenbergen, W.; Thijssen, J.M.; Leeuwen, T.G. van

    2004-01-01

    A double-ring sensor was applied in photoacoustic tomographic imaging of artificial blood vessels as well as blood vessels in a rabbit ear. The peak-to-peak time (tau(pp)) of the laser (1064 nm) induced pressure transient was used to estimate the axial vessel diameter. Comparison with the actual ves

  15. Reduced artery diameters in Klinefelter syndrome.

    Science.gov (United States)

    Foresta, C; Caretta, N; Palego, P; Ferlin, A; Zuccarello, D; Lenzi, A; Selice, R

    2012-10-01

    Various epidemiological studies in relatively large cohorts of patients with Klinefelter syndrome (KS) described the increased morbidity and mortality in these subjects. Our aim was to study the structure and function of arteries in different districts to investigate in these subjects possible alterations. A total of 92 patients having non-mosaic KS, diagnosed in Centre for Human Reproduction Pathology at the University of Padova, and 50 age-matched healthy male controls were studied. Klinefelter syndrome subjects and controls evaluation included complete medical history, physical examination, measurement of concentrations of the reproductive hormones, lipidic and glycidic metabolism, AR function and sensitivity, ultrasound examinations (diameters, carotid intima-media thickness and brachial flow-mediated dilation) of brachial, common carotid and common femoral artery and abdominal aorta. Klinefelter syndrome patients showed significantly reduced artery diameters in all districts evaluated. On the contrary no statistically significant difference was found in cIMT and brachial FMD values between KS patients and controls. Furthermore, we found no statistically significant correlation of artery diameters with reproductive hormones, metabolic parameters, anthropometric measures and weighted CAG repeats. To our knowledge, this is the first study finding a reduced artery diameter in several districts in KS patients compared with that of normal male subjects and overlapping to that of female subjects. We have not an explanation for this phenomenon, even if a possible involvement of genes controlling the development of vascular system might be hypothesized, and further research is required to verify this hypothesis.

  16. Multi-Scale Computational Analyses of JP-8 Fuel Droplets and Vapors in Human Respiratory Airway Models

    Science.gov (United States)

    2007-10-31

    Deposition Clearance and Effects in the Lung 20, 294-309. Kleinstreuer, C., Zhang, Z., 2003. Laminar-to-turbulent fluid-particle flows in a human airway ...FA9550-04-1-0422 Vapors in Human Respiratory Airway Models 5b. GRANT NUMBER Sc. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER Kleinstreuer...tracheobronchial airway models, transient 3- D as well as equivalent steady-state solutions have been obtained for the transport and deposition of

  17. Evaluation of Triethylene Glycol Monomethyl Ether (TRIEGME) as an Alternative Fuel System Icing Inhibitor for JP-8 Fuel

    Science.gov (United States)

    2010-08-01

    could be explained by a non-uniform condensation on the surface of the panel due to non-uniform surface temperatures created by inadequate contact...RXS 10-090 7 RECOMMENDATION Careful engineering review and risk analyses must be performed by weapon systems managers considering switching...heart following prenatal exposure to ethylene glycol monomethyl ether. Drug Chem. Toxicol. 9:1-14. 29. Hoflack, JC; et aI., 1995, Mutat Res, 341(4

  18. Evaluation of Impacts of JP-8+100 on Army Aviation and Ground Vehicles: Phase I Impact Study

    Science.gov (United States)

    2000-11-01

    HILO IAP/HAWAII ISLA 464 121194 16 72196 PTPN PONAPE ISLAND 1 1654 2 3495 SBGL RIO DE JANEIRO IAP 2 640 15 87809 SEGU SIMO BOLIVAR IAP GU 7 6983 61...WALKER FLD, GRAND JU 84 24976 182 71748 0610 LAKE CO. APT LEADVIL 111 19281 1 90 0613 DURANGO-LA PLATA CO. 22 6511 56 37592 0615 EAGLE CO REG APT, GY 966

  19. Comments for the Update to the ATSDR Toxicological Profile for JP-5 and JP-8 Occurring in FY14

    Science.gov (United States)

    2013-12-30

    further mention of any of the UA studies list in Appendix B occurs in the full revised Toxicological Profile, a definitive footnote should be included to...Profile. White, K.L., Delorme, M.P., Beatty, P.W., Smith, M.J., Peachee, V.L. 2013. Jet Fuel Kerosene is not Immunosuppressive in Mice or Rats Following

  20. Jet Propellant (JP)-8 Fuel Evaluation Test Mk II - Reset (Mk II R) Bridge Erection Boat (BEB)

    Science.gov (United States)

    2008-10-01

    diesel engines (fig. 2 and 3) equipped with Delphi rotary fuel injection pumps. Figure 1. Mk II R BEB pushing a two-bay IRB raft. TR No. WF-E-83 2...model 6BTA 5.9-L M2, 210-hp engine having the Delphi rotary fuel injection pump. Major component serial numbers are listed in Table 2. The lubricity... injector pump was loosened, and the manual priming pump was used to verify that fuel was at the injector pump. The bleeder screw was tightened and

  1. Comparison of JP-8 Sprays from a Hydraulically Actuated Electronically Controlled Unit Injector and a Common Rail Injector

    Science.gov (United States)

    2015-10-01

    emissions from combustion. In another study, injection rate meter experiments were performed to characterize the different injection systems [3]. Results...a high pressure compressor. Heating of the ambient gas is supplied by 2 cartridge heaters and a ceramic style heater in the testing section. The

  2. Evaluation of Water Separation and Filter/Coalescer Impact on JP-8 by Next-Generation +100 Thermal Stability Additives

    Science.gov (United States)

    2013-12-01

    turbid appearance. As the emulsion is not easily separated into its components, emulsified water typically passes through the fuel system without affect...several thousands of gallons of fuel, the continuous flow of emulsified fuel/water passing through the test filter repeatedly is representative of the

  3. Air Force JP-8 Fuel Distribution System: A Statistical Analysis to Determine Where and When to Sample

    Science.gov (United States)

    2005-03-01

    1620 1622 1624 DF 10.0489 1744.3385 1754.3874 -LogLike 0.0057 RSquare (U) Likelihood Ratio Pearson Test 20.098 23.765 ChiSquare ... ChiSquare 0.0264 0.0278 Prob>ChiSq Tests Contingency Analysis of Location By Pass Rate 91 Misawa AB Results Lo ca tio n 0.00 0.25 0.50 0.75...0.577 0.308 ChiSquare 0.7494 0.8571 Prob>ChiSq Warning: 20% of cells have expected count less than 5, ChiSquare suspect Tests Contingency

  4. Lagrangian Modeling of Evaporating Sprays at Diesel Engine Conditions: Effects of Multi-Hole Injector Nozzles With JP-8 Surrogates

    Science.gov (United States)

    2014-05-01

    pressure. This is achieved using the modified Pressure Implicit with Splitting of Operator (PISO) algorithm first introduced by Issa [13]. An...2012). 12. Pomraning, E., “Development of Large Eddy Simulation Turbulence Models”,PhD Thesis, University of Wisconsin-Madison, 2000. 13. Issa

  5. Investigative Study to Determine Effects of Hydro-Treated Renewable JP-8 Jet Fuel Blend in Existing Fuels Infrastructure

    Science.gov (United States)

    2012-02-01

    Y Y Y 5083-H112 Wrought Y Y Y Y 3003 Wrought Y Y Y Y 3105 Wrought Y Y Y Y 5010 Wrought Y Y Y Y 5083 Wrought Y Y Y Y 6061-T6 Wrought Y Y Y Y 6063 -T6...Wrought Y Y Y Y 7120- T5 Cast Y Y Y Y 3560-T6 Cast Y Y Y Y Cu, Zn, Sn, Ni and Alloys Elemental Cu Copper R R R Y R R Zn Zinc R R R R R Brass Cu-Zn Brass

  6. A Study of Alternative Approaches to Produce Obscuring Smoke with JP-8 in Vehicle Engine Exhaust Smoke Systems (VEESS)

    Science.gov (United States)

    1989-12-01

    values and Johnson-Grayson for the enthalpies. In the CHEMCAD II run, Soave- Redlich - Kwong models were used for both K-values and enthalpies. The...263 6a. NAME OF PERFORMING ORGANIZATION 6b. OFFICE SYMBOL 7a. NAME OF MONITORING ORGANIZATION Belvoir Fuels and Lubricants (If applicable ) Research

  7. Empirical processes with bounded \\psi_1 diameter

    CERN Document Server

    Mendelson, Shahar

    2010-01-01

    We study the empirical process indexed by F^2=\\{f^2 : f \\in F\\}, where F is a class of mean-zero functions on a probability space. We present a sharp bound on the supremum of that process which depends on the \\psi_1 diameter of the class F (rather than on the \\psi_2 one) and on the complexity parameter \\gamma_2(F,\\psi_2). In addition, we present optimal bounds on the random diameters \\sup_{f \\in F} \\max_{|I|=m} (\\sum_{i \\in I} f^2(X_i))^{1/2} using the same parameters. As applications, we extend several well known results in Asymptotic Geometric Analysis to any isotropic, log-concave ensemble on R^n.

  8. Transfinite diameter of Bernstein sets in

    Directory of Open Access Journals (Sweden)

    Bialas-Cież Leokadia

    2002-01-01

    Full Text Available Let be a compact set in satisfying the following generalized Bernstein inequality: for each such that , for each polynomial of degree where is a constant independent of and , is an infinite set of natural numbers that is also independent of and . We give an estimate for the transfinite diameter of the set : For satisfying the usual Bernstein inequality (i.e., , we prove that

  9. New Large Diameter RF Complex Plasma Device

    Science.gov (United States)

    Meyer, John; Nosenko, Volodymyr; Thomas, Hubertus

    2016-10-01

    The Complex Plasma Research Group at the German Aerospace Center (DLR) in Oberpfaffenhofen has built a new large diameter rf plasma setup for dusty plasma experiments. The vacuum chamber is a stainless steel cylinder 0.90 m in diameter and 0.34 m in height with ports for viewing and measurement. A 0.85 m diameter plate in about the center serves as a powered electrode (13.56 MHz) with the chamber walls as the ground. It is pumped on by one of two Oerlikon turbo pumps with a pumping rate of 1100 l/s or 270 l/s. Argon gas is admitted into the chamber by an MKS mass flow meter and pumping is regulated by a butterfly valve to set pressure for experiments. A manual dropper is used to insert dust into the plasma. The dust is illuminated horizontally by a 660 nm 100 mW laser sheet and viewed from above by a Photron FASTCAM 1024 PCI camera. A vertical laser sheet of 635 nm will be used for side imaging. So far, single-layer plasma crystals of up to 15000 particles have been suspended. The particle velocity fluctuation spectra were measured and from these, the particle charge and screening length were calculated. Future experiments will explore the system-size dependence of the plasma crystal properties.

  10. 29 mm Diameter Test Target Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Olivas, Eric Richard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Naranjo, Angela Carol [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-15

    The Northstar target for Mo99 production is made up of Mo100 disks in a stack separated by coolant gaps for helium flow. A number of targets have been tested at ANL for both production of Mo99 and for thermal-hydraulic performance. These have all been with a 12 mm diameter target, even while the production goals have increased the diameter to now 29 mm. A 29 mm diameter target has been designed that is consistent with the ANL beam capabilities and the capabilities of the helium circulation system currently in use at ANL. This target is designed for 500 μA at 35 MeV electrons. While the plant design calls for 42 MeV, the chosen design point is more favorable and higher power given the limits of the ANL accelerator. The intended beam spot size is 12 mm FWHM, but the thermal analysis presented herein conservatively assumed a 10 mm FWHM beam, which results in a 44% higher beam current density at beam center.

  11. Finned Small Diameter Tube Heat Exchanger

    Science.gov (United States)

    Dang, Chaobin; Daiguji, Hirofumi; Hihara, Eiji; Tokunaga, Masahide

    The performance of fined small tube heat exchangers was investigated both experimentally and theoretically. The Inner diameters of tubes were 1.0mm, 2.1mm and 4.0mm. Exchanged heat and pressure drop obtained from numerical simulation agreed well with the experimental ones. Calculation results show that the volume of a 2.0mm tube heat exchanger can be reduced to 33% of that of a 4mm tube heat exchanger with the same capacity. In addition the distribution of two-phase flow in a branching unit was investigated by measuring downstream temperature distribution. The flow distribution in a branching unit strongly affects the exchanged heat.

  12. Retrobulbar diameter of optic nerve in glaucoma

    Directory of Open Access Journals (Sweden)

    Stefanović Ivan

    2009-01-01

    Full Text Available Introduction. The ultrasound diagnostics of the optic nerve includes the analysis of the optic nerve disc (PNO and measuring of its retrobulbar diameter. With B-scan, by Schraeder's method, it is possible to measure very precisely the optic nerve, the pial diameter, the normal values for the pial diameter being 2.8-4.1 mm. In glaucoma, the disease that is most frequently associated with higher intraocular pressure, there comes the destruction of nerve fibres, which can be visualized as the excavation of the optic nerve disc. Objective. In this paper, we were interested in finding whether in glaucoma, and in what phase of the disease, the optic nerve starts growing thinner. Aware of many forms of this very complex disease, we were interested in knowing if the visualization of excavation on the optic nerve disc is related to diminishing of the pial diameter of the retrobulbar nerve part. Methods. There were treated the patients who had already had the diagnosis of glaucoma and the visualized excavation of the optic disc of various dimensions. Echographically, there was measured the thickness of the retrobulbar part of the optic nerve and the finding compared in relation to the excavation of the optic disc. Results. In all eyes with glaucoma, a normal size of the retrobulbar part of the optic nerve was measured, ranging from 3.01 to 3.91 mm with the median of 3.36 mm. Also, by testing the correlation between the thickness of the optic nerve and the excavation of the PNO, by Pearson test, we found that there was no correlation between these two parameters (r=0.109; p>0.05. Conclusion. In the patients with glaucoma, the retrobulbar part of the optic nerve is not thinner (it has normal values, even not in the cases with a totally excavated optic disc. There is no connection between the size of the PNO excavation and the thickness of the retrobulbar part of the optic nerve.

  13. Measurement of Diameter Changes during Irradiation Testing

    Energy Technology Data Exchange (ETDEWEB)

    Davis, K. L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Knudson, D. L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Crepeau, J. C. [Univ. of Idaho, Idaho Falls, ID (United States); Solstad, S. [Inst. for Energy Technologoy, Halden (Norway)

    2015-03-01

    New materials are being considered for fuel, cladding, and structures in advanced and existing nuclear reactors. Such materials can experience significant dimensional and physical changes during irradiation. Currently in the US, such changes are measured by repeatedly irradiating a specimen for a specified period of time and then removing it from the reactor for evaluation. The time and labor to remove, examine, and return irradiated samples for each measurement makes this approach very expensive. In addition, such techniques provide limited data and handling may disturb the phenomena of interest. In-pile detection of changes in geometry is sorely needed to understand real-time behavior during irradiation testing of fuels and materials in high flux US Material and Test Reactors (MTRs). This paper presents development results of an advanced Linear Variable Differential Transformer-based test rig capable of detecting real-time changes in diameter of fuel rods or material samples during irradiation in US MTRs. This test rig is being developed at the Idaho National Laboratory and will provide experimenters with a unique capability to measure diameter changes associated with fuel and cladding swelling, pellet-clad interaction, and crud buildup.

  14. Sagittal Abdominal Diameter: Application in Clinical Practice

    Directory of Open Access Journals (Sweden)

    Thaís Da Silva-Ferreira

    2014-05-01

    Full Text Available Excess visceral fat is associated with cardiovascular risk factors. Sagittal abdominal diameter (SAD has recently been highlighted as an indicator of abdominal obesity, and also may be useful in predicting cardiovascular risk. The purpose of the present study was to review the scientific literature on the use of SAD in adult nutritional assessment. A search was conducted for scientific articles in the following electronic databases: SciELO , MEDLINE (PubMed and Virtual Health Library. SAD is more associated with abdominal fat (especially visceral, and with different cardiovascular risk factors, such as, insulin resistance, blood pressure, and serum lipoproteins than the traditional methods of estimating adiposity, such as body mass index and waist-to-hip ratio. SAD can also be used in association with other anthropometric measures. There are still no cut-off limits established to classify SAD as yet. SAD can be an alternative measure to estimate visceral adiposity. However, the few studies on this diameter, and the lack of consensus on the anatomical site to measure SAD, are obstacles to establish cut-off limits to classify it.

  15. Fire protection covering for small diameter missiles

    Science.gov (United States)

    Riccitiello, S. R.; Sawko, P. M. (Inventor)

    1979-01-01

    Flexible intumescent protection sheeting of unusually uniform thickness were prepared from epoxy-polysulfide compositions, containing microfibers and the ammonium salt of 1,4-nitroaniline-2-sulfonic acid, as disclosed in U.S. Pat. No. 3,663,464, except that an ammonium salt particle size in the order of 5 to 8 microns and a fiber size of about 1/128th inch in length and 3 to 5 microns in diameter were found critical to obtain the required density of 1.46 to 1.50 g/cc. The insulation sheeting was prepared by a continuous process involving vacuum mixing, calendering, and curing under very strict conditions which depend to some extent upon the thickness of the sheet produced.

  16. LED-based digital diameter measurement

    Science.gov (United States)

    Kleuver, Wolfram; Becker, Lothar

    1995-01-01

    This paper presents a new industrial sensor for measuring diameters of extreme thin objects. The system is divided in two parts. The first is the emitter and the second the receiver. It is possible to use this system for the automatic inspection of files and wires in the textile industries and wire works. Another application for the sensor is the control of production of chemical files in an extruder. Furthermore we can measure more than one object in the lightbeam because we get information not only about the dimensions also about the position of the objects in the beam. The innovation in this system is the using of a light emitting diode (LED) as emitter and the realization of a long distance of about two or more meters between the two sensorheads. The results of this development are a special kind of optical layout in the emitter to reduce the loss of intensity and minimize the divergence of the lightbeam. It is not necessary to develop an intensity distribution, which is equal over the complete width of the sensorhead. We can show that we have a better dynamic in the system with this feature. The experiments prove that we get the same resolution as a laserbeamsensor. Furthermore one advantage is the eye-safety.

  17. Cross-Correlation of Diameter Measures for the Co-Registration of Forest Inventory Plots with Airborne Laser Scanning Data

    Directory of Open Access Journals (Sweden)

    Jean-Matthieu Monnet

    2014-09-01

    Full Text Available Continuous maps of forest parameters can be derived from airborne laser scanning (ALS remote sensing data. A prediction model is calibrated between local point cloud statistics and forest parameters measured on field plots. Unfortunately, inaccurate positioning of field measures lead to a bad matching of forest measures with remote sensing data. The potential of using tree diameter and position measures in cross-correlation with ALS data to improve co-registration is evaluated. The influence of the correction on ALS models is assessed by comparing the accuracy of basal area prediction models calibrated or validated with or without the corrected positions. In a coniferous, uneven-aged forest with high density ALS data and low positioning precision, the algorithm co-registers 91% of plots within two meters from the operator location when at least the five largest trees are used in the analysis. The new coordinates slightly improve the prediction models and allow a better estimation of their accuracy. In a forest with various stand structures and species, lower ALS density and differential Global Navigation Satellite System measurements, position correction turns out to have only a limited impact on prediction models.

  18. Mockup Small-Diameter Air Distribution System

    Energy Technology Data Exchange (ETDEWEB)

    A. Poerschke and A. Rudd

    2016-05-01

    This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses an additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.

  19. Body diameters in 3 - 6 years old children from Plovdiv

    Directory of Open Access Journals (Sweden)

    Tineshev Slavi

    2013-01-01

    Full Text Available The purpose of the research is to analyze the body diameters in 3-6 year old children. The biacromial diameters were taken as well as the two chest diameters, the bicristal and bitrohanterial diameters in 316 children (157 boys and 159 girls 3, 4, 5 and 6 years of age attending kindergarten in Plovdiv. The analysis shows that all diameters, with the exception of the bitrohanterial have higher values in boys. The absolute year's increment of the diameters is greater in girls. The growth velocity of the researched features is greatest at the age of 3-4 and 4-5, decreasing at different rates for the different features at the age of 5-6. The only exception is the sagittal chest diameter in both sexes and the bitrohanterial diameters in girls.

  20. Numerical Simulation of Large Diameter Cylindrical Structure Slamming

    Institute of Scientific and Technical Information of China (English)

    XU Jing; WANG De-yu

    2008-01-01

    The water entry of large diameter cylindrical structure is studied by applying numerical simulation method. The processes of different diameter cylindrical structures impacting water with various constant velocities are calculated numerically. Thereafter, analyzed are the distribution of slamming pressure on structure during slamming course and the influence of slamming velocity and cylindrical diameter on slamming process. Furthermore, presented herein is an equation being used to forecast the peak slamming force on a large diameter cylindrical structure.

  1. The diameter-dependent photoelectrochemical performance of silicon nanowires.

    Science.gov (United States)

    Zhang, Bing-Chang; Wang, Hui; He, Le; Duan, Chun-Yang; Li, Fan; Ou, Xue-Mei; Sun, Bao-Quan; Zhang, Xiao-Hong

    2016-01-25

    We demonstrate the first systematic study of the diameter-dependent photoelectrochemical performance of single silicon nanowires within a broad size range from 200 to 2000 nm. SiNWs with a diameter of 1415 nm exhibit the highest solar energy conversion efficiency, which can be mainly traced to their diameter-dependent light absorption properties.

  2. The k-Diameter of a Kind of Circulant Graph

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xian-di

    2004-01-01

    The diameter of a graph G is the maximal distance between pairs of vertices of G. When a network is modeled as a graph,diameter is a measurement for maximum transmission delay. The k-diameter dk(G) of a graph G, which deals with k internally disjoint paths between pairs of vertices of G, is a extension of the diameter of G. It has widely studied in graph theory and computer science. The circulant graph is a group-theoretic model of a class of symmetric interconnection network. Let Cn(i, ) be a circulant graph of order n whose spanning elements are i and , where n≥4 and n is even. In this paper, the diameter, 2-diameter and 3-diameter of the Cn(i,) are all obtained if gcd(n,i)=1, where the symbol gcd(n,i) denotes the maximum common divisor of n and i.

  3. Tool Geometry for Friction Stir Welding—Optimum Shoulder Diameter

    Science.gov (United States)

    Mehta, M.; Arora, A.; de, A.; Debroy, T.

    2011-09-01

    The most important geometric parameter in the friction stir welding (FSW) tool design is the shoulder diameter, which is currently estimated by trial and error. Here, we report a combined experimental and theoretical investigation on the influence of shoulder diameter on thermal cycles, peak temperatures, power requirements, and torque during FSW of AA7075-T6. An optimum tool shoulder diameter is identified using a three-dimensional, heat transfer and materials flow model. First, the predictive capability of the model is tested by comparing the computed values of peak temperature, spindle power, and torque requirements for various shoulder diameters against the corresponding experimental data. The change in the values of these variables with shoulder diameter is correctly predicted by the model. The model is then used to identify the optimum tool shoulder diameter that facilitates maximal use of the supplied torque in overcoming interfacial sticking. The tool with optimum shoulder diameter is shown to result in acceptable yield strength (YS) and ductility.

  4. Characteristics of Angora rabbit fiber using optical fiber diameter analyzer.

    Science.gov (United States)

    Rafat, S A; de Rochambeau, H; Brims, M; Thébault, R G; Deretz, S; Bonnet, M; Allain, D

    2007-11-01

    An experiment was conducted to describe the characteristics of Angora rabbit fiber using optical fiber diameter analyzer (OFDA). A total of 349 fleece samples were collected from 60 French Angora rabbits. Recorded measurements of OFDA were as follows: mean fiber diameter, CV of fiber diameter, comfort factor, spinning fineness, mean fiber curvature, SD of fiber curvature, mean opacity of fibers, percentage of medullated fibers, mean fiber diameter along the length, and SD of fiber diameter along the length. Comfort factor is the percentage of fibers less than or equal to 30 microns. The main effects included in the mixed model were fixed effects of group, harvest season, and age and a random effect of animal. Correlations among total fleece weight, compression, and OFDA measurements were calculated. Mean fiber diameter was lower than the fiber diameter along the length. Mean percentage of medullated fibers was very low and ranged from 0.1 to 7.3%. The mean comfort factor was 97.5% and ranged from 93.3 to 99.8%. The mean fiber curvature was 40.1 degrees/mm. The major changes in Angora fleece characteristics from 8 to 105 wk of age were an increase in fiber diameter, CV of fiber diameter, mean fiber diameter along the length and curvature, and a decrease in compression and comfort factor. The effect of harvest season was significant on some fiber characteristics. Mean fiber diameter and the mean fiber diameter along the length had a positive correlation with total fleece weight. The OFDA methodology is a method to evaluate fiber diameter, CV of fiber diameter, and bristle content through measuring of the comfort factor. However, OFDA is not adapted for measuring opacity or size of the medulla, or both, in Angora wool and needs a new definition or a special calibration. The spinning fineness should be redefined and adapted for Angora rabbits.

  5. Estimation of genetic parameters for wool fiber diameter measures.

    Science.gov (United States)

    Iman, N Y; Johnson, C L; Russell, W C; Stobart, R H

    1992-04-01

    Genetic and phenotypic correlations and heritability estimates of side, britch, and core diameters; side and britch CV; side and britch diameter difference; and clean fleece weight were investigated using 385 western white-faced ewes produced by 50 sires and maintained at two locations on a selection study. Data were analyzed using analysis of variance procedures, and effects in the final model included breed of sire-selection line combination, sire within breed-selection line, and location. Heritabilities were estimated by paternal half-sib analysis. Sires within breed-selection line represented a significant source of variation for all traits studied. Location had a significant effect on side diameter, side and britch diameter difference, and clean fleece weight. Age of ewe only affected clean fleece weight. Phenotypic and genetic correlations among side, britch, and core diameter measures were high and positive. Phenotypic correlations ranged from .68 to .75 and genetic correlations ranged from .74 to .89. The genetic correlations between side and britch diameter difference and side diameter or core diameter were small (-.16 and .28, respectively). However, there was a stronger genetic correlation between side and britch diameter difference and britch diameter (.55). Heritability of the difference between side and britch diameter was high (.46 +/- .16) and similar to heritability estimates reported for other wool traits. Results of this study indicate that relatively rapid genetic progress through selection for fiber diameter should be possible. In addition, increased uniformity in fiber diameter should be possible through selection for either side and britch diameter difference or side or britch CV.

  6. Analysis of Gear Wheel-shaft Joint Characterized by Comparable Pitch Diameter and Mounting Diameter

    Directory of Open Access Journals (Sweden)

    J. Ryś

    2003-01-01

    Full Text Available This paper presents the design procedure for a gear wheel-shaft direct frictional joint. The small difference between the operating pitch diameter of the gear and the mounting diameter of the frictional joint is the key feature of the connection. The contact surface of the frictional joint must be placed outside the bottom land of the gear, and the geometry of the joint is limited to the specific type of solutions.The strength analysis is based on the relation between the torque and statistical load intensity of the gear transmission. Several dimensionless parameters are introduced to simplify the calculations. Stress-strain verifying analysis with respect to combined loading, the condition of appropriate load-carrying capacity of the frictional joint and the fatigue strength of the shaft are applied to obtain the relations between the dimensions of the joint and other parameters. The final engineering solution may then be suggested. The approach is illustrated by a numerical example.The proposed procedure can be useful in design projects for small, high-powered modern reducers and new-generation geared motors, in particular when manufactured in various series of types.

  7. Effect of Adsorbent Diameter on the Performance of Adsorption Refrigeration

    Institute of Scientific and Technical Information of China (English)

    黄宏宇; 何兆红; 袁浩然; 小林敬幸; 赵丹丹; 窪田光宏; 郭华芳

    2014-01-01

    Adsorbents are important components in adsorption refrigeration. The diameter of an adsorbent can af-fect the heat and mass transfer of an adsorber. The effect of particle diameter on effective thermal conductivity was investigated. The heat transfer coefficient of the refrigerant and the void rate of the adsorbent layer can also affect the effective thermal conductivity of adsorbents. The performance of mass transfer in the adsorber is better when pressure drop decreases. Pressure drop decreases with increasing permeability. The permeability of the adsorbent layer can be improved with increasing adsorbent diameter. The effect of adsorbent diameter on refrigeration output power was experimentally studied. Output power initially increases and then decreases with increasing diameter under different cycle time conditions. Output power increases with decreasing cycle time under similar diameters.

  8. On super edge-graceful trees of diameter four

    CERN Document Server

    Krop, E; Raridan, C

    2011-01-01

    In "On the super edge graceful trees of even orders," Chung, Lee, Gao, and Schaffer posed the following problem: Characterize trees of diameter 4 which are super edge-graceful. In this paper, we provide super edge-graceful labelings for all caterpillars and even size lobsters of diameter 4 which permit such labelings. We also provide super edge-graceful labelings for several families of odd size lobsters of diameter 4.

  9. k-Diameter of Circulant Graph with Degree 3

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xian-di; LI Man-li

    2005-01-01

    Parameters k-distance and k-diameter are extension of the distance and the diameter in graph theory. In this paper, the k-distance dk (x,y) between the any vertices x andy is first obtained in a connected circulant graph G with order n (n is even) and degree 3 by removing some vertices from the neighbour set of the x. Then, the k-diameters of the connected circulant graphs with order n and degree 3 are given by using the k-diameter dk (x, y).

  10. Mean particle diameters: from statistical definition to physical understanding

    NARCIS (Netherlands)

    Alderliesten, M.

    2008-01-01

    Mean particle diameters are important for the science of particulate systems. This thesis deals with a definition system for these mean diameters, called Moment-Ratio (M-R) definition system, and provides a general statistical and physical basis. Also, the current DIN/ISO definition system is discus

  11. Effect of flow rate on diameter of electrospun nanoporous fibers

    Directory of Open Access Journals (Sweden)

    Tang Xiao-Peng

    2014-01-01

    Full Text Available The effect of flow rate on the diameter of the charged jet in the electrospinning process is studied theoretically. The obtained theoretical results offer in-depth physical understanding and mechanism of nanoporous fibers. It also reveals that the morphology and diameter of nanoporous microspheres can be controlled by the flow rate.

  12. Reliable Diameter Control of Carbon Nanotube Nanobundles Using Withdrawal Velocity

    Science.gov (United States)

    Shin, Jung Hwal; Kim, Kanghyun; An, Taechang; Choi, WooSeok; Lim, Geunbae

    2016-09-01

    Carbon nanotube (CNT) nanobundles are widely used in nanoscale imaging, fabrication, and electrochemical and biological sensing. The diameter of CNT nanobundles should be controlled precisely, because it is an important factor in determining electrode performance. Here, we fabricated CNT nanobundles on tungsten tips using dielectrophoresis (DEP) force and controlled their diameters by varying the withdrawal velocity of the tungsten tips. Withdrawal velocity pulling away from the liquid-air interface could be an important, reliable parameter to control the diameter of CNT nanobundles. The withdrawal velocity was controlled automatically and precisely with a one-dimensional motorized stage. The effect of the withdrawal velocity on the diameter of CNT nanobundles was analyzed theoretically and compared with the experimental results. Based on the attachment efficiency, the withdrawal velocity is inversely proportional to the diameter of the CNT nanobundles; this has been demonstrated experimentally. Control of the withdrawal velocity will play an important role in fabricating CNT nanobundles using DEP phenomena.

  13. Heritability of retinal vessel diameters and blood pressure

    DEFF Research Database (Denmark)

    Taarnhøj, Nina C B B; Larsen, Michael; Sander, Birgit

    2006-01-01

    PURPOSE: To assess the relative influence of genetic and environmental effects on retinal vessel diameters and blood pressure in healthy adults, as well as the possible genetic connection between these two characteristics. METHODS: In 55 monozygotic and 50 dizygotic same-sex healthy twin pairs......%-80%) for CRAE, 83% (95% CI: 73%-89%) for CRVE, and 61% (95% CI: 44%-73%) for mean arterial blood pressure (MABP). Retinal artery diameter decreased with increasing age and increasing arterial blood pressure. Mean vessel diameters in the population were 165.8 +/- 14.9 microm for CRAE, 246.2 +/- 17.7 microm...... and blood glucose, variations in retinal blood vessel diameters and blood pressure were predominantly attributable to genetic effects. A genetic influence may have a role in individual susceptibility to hypertension and other vascular diseases. The results suggest that retinal vessel diameters...

  14. Superresolution measurement of nanofiber diameter by modes beating

    Science.gov (United States)

    Fenton, E. F.; Solano, P.; Hoffman, J. E.; Orozco, L. A.; Rolston, S. L.; Fatemi, F. K.

    2016-05-01

    Nanofibers are becoming an important tool in quantum information technologies for coupling photonics systems to atomic systems. Nondestructive techniques for characterizing these nanofibers prior to integration into an apparatus are desirable. In this work, we probe the light propagating in a fused silica optical nanofiber (750-nm-diameter) by coupling it evanescently to a 6- μm-diameter microfiber that is scanned along the nanofiber length. This technique is capable of observing all possible beat lengths among different propagating modes. The beat lengths are strongly dependent on the nanofiber diameter and refractive index of the fiber. The steep dependence has enabled measurements of the fiber diameter with sub-Angstrom sensitivity. The diameter extracted from the beat length measurements agrees with a measurement made using scanning electron microscopy. Work supported by NSF.

  15. Diameter of common bile duct: what are the predicting factors?

    Directory of Open Access Journals (Sweden)

    Atoosa Adibi

    2007-07-01

    Full Text Available

    BACKGROUND: This was a study to determine the correlation between the common bile duct (CBD diameter and demographic data, fasting, and the history of opium addiction.
    METHODS: This was a cross-sectional study on 375 patients (>16 years old including 219 females and 156 males. They had no evident hepatobiliary or pancreatic disease and underwent abdominopelvic ultrasonography for measurement of their CBD diameter. Ultrasound (US was performed to measure CBD diameter at the porta hepatis (proximal part and behind the head of the pancreas (distal part. Correlation coefficients for the association between CBD diameter and predictive factors were calculated. t-test was applied to compare the means between the groups.
    RESULTS: The mean CBD diameter (1 standard deviation, in proximal and distal parts were 3.64 mm (±1.2 and 3.72 mm (±1.2, respectively. The CBD diameters (proximal and distal were significantly (P<0.05 correlated with age (r = 0.55 and 0.54, respectively, BMI (r = 0.25 and 0.27, respectively and portal vein diameter (r = 0.24 and 0.22, respectively. Distal diameter of CBD was significantly larger in opium addicts (5.66 ± 2.65 in comparison with non addicts (3.68 ± 1.17, P = 0.04.
    CONCLUSIONS: CBD diameter associates with age, BMI, portal vein diameter and opium addiction. CBD dilatation, if it can not be explained by age, opium usage or large BMI, should be evaluated further to rule out obstruction.
    KEY WORDS: Common bile duct, predicting factors, ultrasonography.

  16. Association between axial length and horizontal and vertical globe diameters.

    Science.gov (United States)

    Jonas, Jost B; Ohno-Matsui, Kyoko; Holbach, Leonard; Panda-Jonas, Songhomitra

    2017-02-01

    To assess relationships between axial length and the horizontal and vertical globe diameters. The study consisted of enucleated human eyes. The horizontal, vertical, and sagittal diameters were measured. The study included 135 globes removed because of malignant uveal melanoma (111 globes) or end-stage painful glaucoma (n = 24 eyes). Mean axial, horizontal, and vertical diameters were 24.6 ± 2.6 mm (range: 20-35 mm), 23.7 ± 1.4 mm (range: 21-29 mm) and 23.7 ± 1.4 mm (range: 20-29 mm) respectively. The horizontal diameter and vertical diameter did not differ significantly (P = 0.92), while both were significantly (P globe diameter (P globe diameter = 0.84 × horizontal globe diameter + 3.69). The axial diameter was significantly (P 24 mm, the horizontal and vertical globe diameter increased by a lower amount of 0.19 and 0.21 mm, respectively, for each mm increase in axial diameter. Myopic enlargement of the globe beyond an axial length of 24 mm takes place predominantly in the sagittal axis, leading to a change in the globe form from a sphere to an elongated form. It fits with the notion that myopic elongation may occur by an elongation of the eye walls in regions close to the globe's equator.

  17. Diameter-dependent thermodynamic and elastic properties of metallic nanoparticles

    Science.gov (United States)

    Chandra, Jeewan; Kholiya, Kuldeep

    2015-04-01

    A simple theoretical model has been proposed to study the diameter-dependent properties of metallic nanoparticles, i.e. Ag, Au, Al, Ni, Pb, Cu and Fe. The diameter-dependent thermodynamic properties includes melting temperature, Debye temperature, evaporation temperature, melting enthapy and melting entropy. The model is also extended to study the diameter-dependent elastic properties including bulk modulus, Young's modulus and thermal expansion coefficient. On comparison with available experimental findings and other theoretical approaches, the results obtained with the present formulation depict a close agreement and demonstrate the validity of the method proposed in the present paper.

  18. Measurement of fetal biparietal diameter in owl monkeys (Aotus nancymaae).

    Science.gov (United States)

    Schuler, A Michele; Brady, Alan G; Tustin, George W; Parks, Virginia L; Morris, Chris G; Abee, Christian R

    2010-09-01

    Owl monkeys are New World primates frequently used in biomedical research. Despite the historical difficulty of breeding owl monkeys in captivity, several productive owl monkey breeding colonies exist currently. The animals in the colony we describe here are not timed-pregnant, and determination of gestational age is an important factor in prenatal care. Gestational age of human fetuses is often determined by using transabdominal measurements of fetal biparietal diameter. The purpose of this study was to correlate biparietal diameter measurements with gestational age in owl monkeys. We found that biparietal diameter can be used to accurately predict gestational age in owl monkeys.

  19. The Non-Homologous Nature of Solar Diameter Variations

    CERN Document Server

    Sofia, S; Demarque, P; Li, L; Thuillier, G; Sofia, Sabatino; Basu, Sarbani; Demarque, Pierre; Li, Linghuai; Thuillier, Gerard

    2005-01-01

    We show in this paper that the changes of the solar diameter in response to variations of large scale magnetic fields and turbulence are not homologous. For the best current model, the variation at the photospheric level is over 1000 times larger than the variation at a depth of 5 Mm, which is about the level at which f-mode solar oscillations determine diameter variations. This model is supported by observations that indicate larger diameter changes for high degree f-modes than for low degree f-modes, since energy of the former are concentrated at shallower layers than the latter.

  20. Tool electrode wear in electrical discharge of small diameter holes

    Directory of Open Access Journals (Sweden)

    Slătineanu Laurenţiu

    2017-01-01

    Full Text Available In the paper, the problem of obtaining small diameter holes in workpieces made of high speed steel by electrical discharge machining was formulated. A fulfil factorial experiment was designed and materialized, taking into consideration the tool electrode diameter, pulse on time and pulse off time as independent variables. The tool electrode wear was evaluated by means of the decrease of tool electrode mass and length. On the base of experimental results, power type empirical mathematical models were determined. One noticed the higher influence exerted by the too electrode diameter, whose increase determine the decrease of the tool electrode.

  1. Relationship of rolling bearing stiffness with diameter of roller

    Institute of Scientific and Technical Information of China (English)

    郭茂林; 王刚; 张瑞

    2002-01-01

    The theoretical formula of roller bearing stiffness is induced and compared with its empirical formula.In the experience formula the stiffness of roller bearing has nothing to do with the roller diameter. The relation-ship of roller bearing stiffness with roller diameter was studied using Hz contacting theory. It is concluded thatconclusion in experience formula is only approximate result of data processing under special conditions, and therelation between stiffness of roller bearing and roller diameter must be taken into consideration while designingor selecting roller bearings.

  2. Porosity Assessment for Different Diameters of Coir Lignocellulosic Fibers

    Science.gov (United States)

    da Luz, Fernanda Santos; Paciornik, Sidnei; Monteiro, Sergio Neves; da Silva, Luiz Carlos; Tommasini, Flávio James; Candido, Verônica Scarpini

    2017-08-01

    The application of natural lignocellulosic fibers (LCFs) in engineering composites has increased interest in their properties and structural characteristics. In particular, the inherent porosity of an LCF markedly affects its density and the adhesion to polymer matrices. For the first time, both open and closed porosities of a natural LCF, for different diameter ranges, were assessed. Fibers extracted from the mesocarp of the coconut fruit were investigated by nondestructive methods of density measurements and x-ray microtomography (microCT). It was found that, for all diameter ranges, the closed porosity is significantly higher than the open porosity. The total porosity increases with diameter to around 60% for coir fibers with more than 503 μm in diameter. The amount and characteristics of these open and closed porosities were revealed by t test and Weibull statistics as well as by microCT.

  3. Heritability of retinal vessel diameters and blood pressure

    DEFF Research Database (Denmark)

    Taarnhøj, Nina C B B; Larsen, Michael; Sander, Birgit

    2006-01-01

    PURPOSE: To assess the relative influence of genetic and environmental effects on retinal vessel diameters and blood pressure in healthy adults, as well as the possible genetic connection between these two characteristics. METHODS: In 55 monozygotic and 50 dizygotic same-sex healthy twin pairs......%-80%) for CRAE, 83% (95% CI: 73%-89%) for CRVE, and 61% (95% CI: 44%-73%) for mean arterial blood pressure (MABP). Retinal artery diameter decreased with increasing age and increasing arterial blood pressure. Mean vessel diameters in the population were 165.8 +/- 14.9 microm for CRAE, 246.2 +/- 17.7 microm...... for CRVE, and 0.67 +/- 0.05 microm for AVR. No significant influence on artery or vein diameters was found for gender, smoking, body mass index (BMI), total cholesterol, fasting blood glucose, or 2-hour oral glucose tolerance test values. CONCLUSIONS: In healthy young adults with normal blood pressure...

  4. Study of Linearly Polarized Light Measuring Fiber Diameter

    Energy Technology Data Exchange (ETDEWEB)

    Liang Hong, E-mail: lianghong@cuc.edu.cn [School of science, Communication University of China 100024 (China)

    2011-02-01

    The letter discusses a new way to measure fiber diameters, studies the theory of measuring fiber radius using this way, carries out numerical simulation based on this and provides experiment method as well.

  5. Eddy sensors for small diameter stainless steel tubes.

    Energy Technology Data Exchange (ETDEWEB)

    Skinner, Jack L.; Morales, Alfredo Martin; Grant, J. Brian; Korellis, Henry James; LaFord, Marianne Elizabeth; Van Blarigan, Benjamin; Andersen, Lisa E.

    2011-08-01

    The goal of this project was to develop non-destructive, minimally disruptive eddy sensors to inspect small diameter stainless steel metal tubes. Modifications to Sandia's Emphasis/EIGER code allowed for the modeling of eddy current bobbin sensors near or around 1/8-inch outer diameter stainless steel tubing. Modeling results indicated that an eddy sensor based on a single axial coil could effectively detect changes in the inner diameter of a stainless steel tubing. Based on the modeling results, sensor coils capable of detecting small changes in the inner diameter of a stainless steel tube were designed, built and tested. The observed sensor response agreed with the results of the modeling and with eddy sensor theory. A separate limited distribution SAND report is being issued demonstrating the application of this sensor.

  6. Improved Design Basis for Laterally Loaded Large Diameter Pile

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane

    of up-to-date facilities has been: Equipment for controlling centrifuge tests, data acquisition, preparation of test samples and equipment for and making of lateral load tests. The present research has been narrowed to investigate the static and cyclic behaviour of stiff piles with a diameter of 1-3 m...... on the structure and the productivity of the turbine. Current design practice for monopiles are based on p-y curves developed for slender piles with a diameter of 0.6 m. The focus on the structure stiffness has entailed a significant research on the soil-structure interaction for large diameter monopiles....... Comparison of the different approaches shows some discrepancy and conflicting statements, but the main findings can be summarized as: • The standard p-y curves are inadequate to describe the behaviour of lateral loaded large diameter rigid piles. • Initial stiffness of the p-y curves is depended...

  7. Pupil diameter reflects uncertainty in attentional selection during visual search

    Directory of Open Access Journals (Sweden)

    Joy J. Geng

    2015-08-01

    Full Text Available Pupil diameter has long been used as a metric of cognitive processing. However, recent advances suggest that the cognitive sources of change in pupil size may reflect LC-NE function and the calculation of unexpected uncertainty in decision processes (Aston-Jones & Cohen, 2005b; Yu & Dayan, 2005. In the current experiments, we explored the role of uncertainty in attentional selection on task-evoked changes in pupil diameter during visual search. We found that task-evoked changes in pupil diameter were related to uncertainty during attentional selection as measured by reaction time and performance accuracy (Experiments 1-2. Control analyses demonstrated that the results are unlikely to be due to error monitoring or response uncertainty. Our results suggest that pupil diameter can be used as an implicit metric of uncertainty in ongoing attentional selection requiring effortful control processes.

  8. Is ultrasonographically detected nodule diameter concordant with pathological tumor size?

    Science.gov (United States)

    Bilginer, Muhammet Cuneyt; Ozdemir, Didem; Baser, Husniye; Dogan, Hayriye Tatli; Yalcin, Abdussamed; Ersoy, Reyhan; Cakir, Bekir

    2017-06-01

    We aimed to compare preoperative ultrasonographical and postoperative histopathological diameters of differentiated thyroid cancer (DTC) lesions and investigate possible factors that can predict the discordance between two measurements. Data of patients with histopathologically confirmed DTC were reviewed retrospectively. Nodules evaluated by preoperative US were matched with histopathologically examined nodules. Incidental tumors and nodules that can not be matched in US and histopathology reports were excluded. Preoperative US diameter and postoperative histopathological size were compared and percentage difference between two measurements was calculated for each lesion. There were 607 DTC foci in 562 patients. Mean US diameter was significantly higher than histopathological diameter (21.0 ± 15.6 mm vs 17.3 ± 13.6, p size in 444 (73.1%), equal in 15 (2.5%) and lower in 148 (24.4%) nodules. Marginal irregularity was observed in 253 (57%) lesions with US diameter > tumor size and 108 (73%) lesions with US diameter size (p = 0.010). Rate of nodules with peripheral halo was higher in lesions with US diameter > tumor size (30.6% vs 20.3%, p = 0.015). In nodules with US diameter > tumor size, percentage difference was lower in nodules with microcalcification (p = 0.020) and higher in cytologically benign nodules (p size, size in a considerable ratio of DTCs. It might be helpful to consider this discordance while deciding surgical extent in these patients. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  9. Minimum Orders of Eulerian Oriented Digraphs with Given Diameter

    Institute of Scientific and Technical Information of China (English)

    Yoomi RHO; Byeong Moon KIM; Woonjae HWANG; Byung Chul SONG

    2014-01-01

    A digraph D is oriented if it does not contain 2-cycles. If an oriented digraph D has a directed eulerian path, it is an oriented eulerian digraph. In this paper, when an oriented eulerian digraph D has minimum out-degree 2 and a diameter d, we find the minimum order of D. In addition, when D is 2-regular with diameter 4m (m≥2), we classify the extremal cases.

  10. Catalytic growth of carbon nanotubes with large inner diameters

    Directory of Open Access Journals (Sweden)

    WEI REN ZHONG

    2005-02-01

    Full Text Available Carbon nanotubes (2.4 g/g catalyst, with large inner diameters were successfully synthesized through pyrolysis of methane on a Ni–Cu–Al catalyst by adding sodium carbonate into the carbon nanotubes growth system. The inner diameter of the carbon nanotubes prepared by this method is about 20–60 nm, while their outer diameter is about 40–80 nm. Transmission electron microscopy and X-ray diffraction were employed to investigate the morphology and microstructures of the carbon nanotubes. The analyses showed that these carbon nanotubes have large inner diameters and good graphitization. The addition of sodium carbonate into the reaction system brings about a slight decrease in the methane conversion and the yield of carbon. The experimental results showed that sodium carbonate is a mildly toxic material which influenced the catalytic activity of the Ni–Cu–Al catalyst and resulted in the formation of carbon nanotubes with large inner diameters. The growth mechanism of the carbon nanotubes with large inner diameters is discussed in this paper.

  11. Diameter dependence of thermoelectric power of semiconducting carbon nanotubes

    Science.gov (United States)

    Hung, Nguyen T.; Nugraha, Ahmad R. T.; Hasdeo, Eddwi H.; Dresselhaus, Mildred S.; Saito, Riichiro

    2015-10-01

    We calculate the thermoelectric power (or thermopower) of many semiconducting single wall carbon nanotubes (s-SWNTs) within a diameter range 0.5 -1.5 nm by using the Boltzmann transport formalism combined with an extended tight-binding model. We find that the thermopower of s-SWNTs increases as the tube diameter decreases. For some s-SWNTs with diameters less than 0.6 nm , the thermopower can reach a value larger than 2000 μ V /K at room temperature, which is about 6 to 10 times larger than that found in commonly used thermoelectric materials. The large thermopower values may be attributed to the one dimensionality of the nanotubes and to the presence of large band gaps of the small-diameter s-SWNTs. We derive an analytical formula to reproduce the numerical calculation of the thermopower and we find that the thermopower of a given s-SWNT is directly related with its band gap. The formula also explains the shape of the thermopower as a function of tube diameter, which looks similar to the shape of the so-called Kataura plot of the band gap dependence on tube diameter.

  12. Failure Diameter of PBX 9502: Simulations with the SURFplus model

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-03

    SURFplus is a reactive burn model for high explosives aimed at modelling shock initiation and propagation of detonation waves. It utilizes the SURF model for the fast hot-spot reaction plus a slow reaction for the energy released by carbon clustering. A feature of the SURF model is that there is a partially decoupling between burn rate parameters and detonation wave properties. Previously, parameters for PBX 9502 that control shock ini- tiation had been calibrated to Pop plot data (distance-of-run to detonation as a function of shock pressure initiating the detonation). Here burn rate parameters for the high pres- sure regime are adjusted to t the failure diameter and the limiting detonation speed just above the failure diameter. Simulated results are shown for an uncon ned rate stick when the 9502 diameter is slightly above and slightly below the failure diameter. Just above the failure diameter, in the rest frame of the detonation wave, the front is sonic at the PBX/air interface. As a consequence, the lead shock in the neighborhood of the interface is supported by the detonation pressure in the interior of the explosive rather than the reaction immediately behind the front. In the interior, the sonic point occurs near the end of the fast hot-spot reaction. Consequently, the slow carbon clustering reaction can not a ect the failure diameter. Below the failure diameter, the radial extent of the detonation front decreases starting from the PBX/air interface. That is, the failure starts at the PBX boundary and propagates inward to the axis of the rate stick.

  13. Hole diameters in pet bottles used for fruit fly capture

    Directory of Open Access Journals (Sweden)

    Maurico Paulo Batistella Pasini

    2015-05-01

    Full Text Available Two experiments were conducted during the period from 31 January to 6 March 2012 in Santa Maria, Rio Grande do Sul State, Brazil to determine the efficiency of different hole diameters in PET trap bottles on pests in guava and persimmon orchards. In a randomised block design in a factorial scheme, we assessed the average number adults of Anastrepha fraterculus, Ceratitis capitata (Diptera: Tephitidae and Zaprionus indianus (Diptera: Drosophilidae infruits thatemerged in two situations (in the plant and on the soil; we also assessed the number of captured adults in trap bottlesunder two conditions, different hole diameters and different days after placement of the attractive solution. Smaller diameter sizescaptured more A. fraterculus, C. capitata and Z. indianusadults. The 1.0 cm diameter was the most efficient hole size in reducing the adult emergence of Tephritidae to Z. indianus, whereas the smallest diameter hole sizes, 0.6 and 0.8 cm, showed the highest efficiencies in controlling adult emergence in persimmon fruit and guava fruit.

  14. Parametric Probability Distribution Functions for Axon Diameters of Corpus Callosum

    Directory of Open Access Journals (Sweden)

    Farshid eSepehrband

    2016-05-01

    Full Text Available Axon diameter is an important neuroanatomical characteristic of the nervous system that alters in the course of neurological disorders such as multiple sclerosis. Axon diameters vary, even within a fiber bundle, and are not normally distributed. An accurate distribution function is therefore beneficial, either to describe axon diameters that are obtained from a direct measurement technique (e.g., microscopy, or to infer them indirectly (e.g., using diffusion-weighted MRI. The gamma distribution is a common choice for this purpose (particularly for the inferential approach because it resembles the distribution profile of measured axon diameters which has been consistently shown to be non-negative and right-skewed. In this study we compared a wide range of parametric probability distribution functions against empirical data obtained from electron microscopy images. We observed that the gamma distribution fails to accurately describe the main characteristics of the axon diameter distribution, such as location and scale of the mode and the profile of distribution tails. We also found that the generalized extreme value distribution consistently fitted the measured distribution better than other distribution functions. This suggests that there may be distinct subpopulations of axons in the corpus callosum, each with their own distribution profiles. In addition, we observed that several other distributions outperformed the gamma distribution, yet had the same number of unknown parameters; these were the inverse Gaussian, log normal, log logistic and Birnbaum-Saunders distributions.

  15. Effect of rootstock diameter on apple saplings growth

    Directory of Open Access Journals (Sweden)

    VAHID AVDIU

    2014-03-01

    Full Text Available This research paper presents the results of a field trial with managed nursery trees including two apple cultivars Golden Reinders and Gala Galaxy on the rootstocks M9 and MM 106. In April 2011, the saplings (bench grafted in March 2011 were planted in the distance 100 cm x 35 cm in randomized block design in threecombinations of rootstock diameters (5-7 mm, 7-9 mm, 9-11 mm with threereplications (in total 60 saplings for each apple cultivar-rootstock and combinations in Mirovica, Kosovo. The following parameters were examined: growth, rootstock diameter, scion diameter, and stocks growth dynamic. The experimental design was a ANOVAs one-way analysing two different factors cultivars, rootstocks types and treatments (three combinations of rootstocks diameter. Significant differences were found in scion thickness and sapling growth among the three different combinations of rootstock diameter, dimensions and cultivars. Insignificant were differences were found within factors as cultivar, rootstock and their combinations Key words: Amino acids, Moringa oleifera, poultry manure.

  16. Magnetoimpedance of Electroplated Wires with Large Core Diameters

    Institute of Scientific and Technical Information of China (English)

    C. Sirisathitkul; P. Jantaratana

    2009-01-01

    Monolayered Co and trilayered Co/Cu/Co were electroplated on 485 Μm-diameter Cu wires using the bath pH 2.5. These wires can be functioned as magnetic sensors owing to their magnetoimpedance (Ml) effect. By measuring at four different frequencies (100, 250, 500, and 1000 kHz) and Co thicknesses (2.5, 5.0, 10.0, and 25.0Μm), the Ml ratio of electroplated Co on Cu wires tended to increase with increasing Co thickness and frequency of the driving current. The Co/Cu/Co on Cu wires exhibited even higher Ml ratio. The magnetic layer also regulated the magnetic inductions and anisotropy regardless of the size of nonmagnetic core. Nevertheless, the diameter of the Cu core had a significant effect on the Ml ratio. By comparing with the 47.7 μm-diameter Ag cores electroplated by Co and Co/Cu/Co of the same thickness, the Cu cores with a larger diameter gave rise to a larger Ml ratio because their lower electrical resistance enhanced the crossing effect. Substantial Ml ratio was observed even in a low frequency regime because the skin effect occurred at a low frequency in the case of electroplated wires with large core diameters.

  17. Memory, emotion, and pupil diameter: Repetition of natural scenes.

    Science.gov (United States)

    Bradley, Margaret M; Lang, Peter J

    2015-09-01

    Recent studies have suggested that pupil diameter, like the "old-new" ERP, may be a measure of memory. Because the amplitude of the old-new ERP is enhanced for items encoded in the context of repetitions that are distributed (spaced), compared to massed (contiguous), we investigated whether pupil diameter is similarly sensitive to repetition. Emotional and neutral pictures of natural scenes were viewed once or repeated with massed (contiguous) or distributed (spaced) repetition during incidental free viewing and then tested on an explicit recognition test. Although an old-new difference in pupil diameter was found during successful recognition, pupil diameter was not enhanced for distributed, compared to massed, repetitions during either recognition or initial free viewing. Moreover, whereas a significant old-new difference was found for erotic scenes that had been seen only once during encoding, this difference was absent when erotic scenes were repeated. Taken together, the data suggest that pupil diameter is not a straightforward index of prior occurrence for natural scenes. © 2015 Society for Psychophysiological Research.

  18. Diameter of basalt columns derived from fracture mechanics bifurcation analysis.

    Science.gov (United States)

    Bahr, H-A; Hofmann, M; Weiss, H-J; Bahr, U; Fischer, G; Balke, H

    2009-05-01

    The diameter of columnar joints forming in cooling basalt and drying starch increases with decreasing growth rate. This observation can be reproduced with a linear-elastic three-dimensional fracture mechanics bifurcation analysis, which has been done for a periodic array of hexagonal columnar joints by considering a bifurcation mode compatible with observations on drying starch. In order to be applicable to basalt columns, the analysis has been carried out with simplified stationary temperature fields. The critical diameter differs from the one derived with a two-dimensional model by a mere factor of 1/2. By taking into account the latent heat released at the solidification front, the results agree fairly well with observed column diameters.

  19. On sub-determinants and the diameter of polyhedra

    CERN Document Server

    Bonifas, Nicolas; Eisenbrand, Friedrich; Hähnle, Nicolai; Niemeier, Martin

    2011-01-01

    We derive a new upper bound on the diameter of a polyhedron P = {x \\in R^n : Ax <= b}, where A \\in Z^{m\\timesn}. The bound is polynomial in n and the largest absolute value of a sub-determinant of A, denoted by \\Delta. More precisely, we show that the diameter of P is bounded by O(\\Delta^2 n^4 log n\\Delta). If P is bounded, then we show that the diameter of P is at most O(\\Delta^2 n^3.5 log n\\Delta). For the special case in which A is a totally unimodular matrix, the bounds are O(n^4 log n) and O(n^3.5 log n) respectively. This improves over the previous best bound of O(m^16 n^3 (log mn)^3) due to Dyer and Frieze.

  20. Axon diameter mapping in crossing fibers with diffusion MRI

    DEFF Research Database (Denmark)

    Zhang, Hui; Dyrby, Tim B; Alexander, Daniel C

    2011-01-01

    tissue than measures derived from diffusion tensor imaging. Most existing techniques for axon diameter mapping assume a single axon orientation in the tissue model, which limits their application to only the most coherently oriented brain white matter, such as the corpus callosum, where the single...... orientation assumption is a reasonable one. However, fiber crossings and other complex configurations are widespread in the brain. In such areas, the existing techniques will fail to provide useful axon diameter indices for any of the individual fiber populations. We propose a novel crossing fiber tissue...... of the technique by establishing reasonable axon diameter indices in the crossing region at the interface of the cingulum and the corpus callosum....

  1. The angular diameter and distance of the Cepheid Zeta Geminorum

    CERN Document Server

    Kervella, P; Perrin, G; Schöller, M; Traub, W A; Lacasse, M D

    2001-01-01

    Cepheids are the primary distance indicators for extragalactic astronomy and therefore are of very high astrophysical interest. Unfortunately, they are rare stars, situated very far from Earth.Though they are supergiants, their typical angular diameter is only a few milliarcseconds, making them very challenging targets even for long-baseline interferometers. We report observations that were obtained in the K prime band (2-2.3 microns), on the Cepheid Zeta Geminorum with the FLUOR beam combiner, installed at the IOTA interferometer. The mean uniform disk angular diameter was measured to be 1.64 +0.14 -0.16 mas. Pulsational variations are not detected at a significant statistical level, but future observations with longer baselines should allow a much better estimation of their amplitude. The distance to Zeta Gem is evaluated using Baade-Wesselink diameter determinations, giving a distance of 502 +/- 88 pc.

  2. Improved Design Basis for Laterally Loaded Large Diameter Pile

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane

    . The expected development of offshore wind farms is towards larger farms, larger turbines and larger water depths. Monopiles have been applied widely and it is of interest to investigate the possibilities to further optimize the design and in particular the modelling of the soil-structure interaction...... on the structure and the productivity of the turbine. Current design practice for monopiles are based on p-y curves developed for slender piles with a diameter of 0.6 m. The focus on the structure stiffness has entailed a significant research on the soil-structure interaction for large diameter monopiles...... in dry sand by use of centrifuge modelling and to compare the findings with the standard p-y curves. It has been chosen to apply piles with an embedment length of 6 to 10 times the diameter of the applied piles. The general static behaviour of monopiles in dry sand has based on centrifuge tests been...

  3. Reduced arterial diameter during static exercise in humans

    DEFF Research Database (Denmark)

    Olesen, H L; Mitchell, J H; Friedman, D B

    1995-01-01

    of another limb. Static exercise increased heart rate and mean arterial pressure, which were largest during one-leg knee extension. After exercise heart rate and mean arterial pressure returned to the resting level. No changes were recorded in arterial carbon dioxide tension, and the rate of perceived......In eight subjects luminal diameter of the resting limb radial and dorsalis pedis arteries was determined by high-resolution ultrasound (20 MHz). This measurement was followed during rest and during 2 min of static handgrip or of one-leg knee extension at 30% of maximal voluntary contraction...... exertion was approximately 15 units after both types of exercise. The dorsalis pedis arterial diameter was 1.50 +/- 0.20 mm (mean and SE) and the radial AD 2.45 +/- 0.12 mm. During both types of contractions the luminal diameters decreased approximately 3.5% within the first 30 s (P

  4. Directional Solidification and Convection in Small Diameter Crucibles

    Science.gov (United States)

    Chen, J.; Sung, P. K.; Tewari, S. N.; Poirier, D. R.; DeGroh, H. C., III

    2003-01-01

    Pb-2.2 wt% Sb alloy was directionally solidified in 1, 2, 3 and 7 mm diameter crucibles. Pb-Sb alloy presents a solutally unstable case. Under plane-front conditions, the resulting macrosegregation along the solidified length indicates that convection persists even in the 1 mm diameter crucible. Al-2 wt% Cu alloy was directionally solidified because this alloy was expected to be stable with respect to convection. Nevertheless, the resulting macrosegregation pattern and the microstructure in solidified examples indicated the presence of convection. Simulations performed for both alloys show that convection persists for crucibles as small as 0.6 mm of diameter. For the solutally stable alloy, Al-2 wt% Cu, the simulations indicate that the convection arises from a lateral temperature gradient.

  5. Improved Design Basis for Laterally Loaded Large Diameter Pile

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane

    in dry sand by use of centrifuge modelling and to compare the findings with the standard p-y curves. It has been chosen to apply piles with an embedment length of 6 to 10 times the diameter of the applied piles. The general static behaviour of monopiles in dry sand has based on centrifuge tests been...... in sand by use of physical modelling and comparison of the findings with standard p-y curves. The present research is based on use of the centrifuge facilities at Danish Technical University (DTU), the sole geotechnical centrifuge in Scandinavia. It became evident in the initial phase of the research...... that the available centrifuge facilities at DTU was outdated and the focus was changed to establish up-to-date centrifuge facilities for medium to large diameter piles, and to initiate the research on the behaviour of large diameter piles in sand under static and cyclic loading. Key elements in the establishment...

  6. Application of direct tracking method for measuring electrospun nanofiber diameter

    Directory of Open Access Journals (Sweden)

    M. Ziabari

    2009-03-01

    Full Text Available In this paper, direct tracking method as an image analysis based technique for measuring electrospun nanofiber diameter has been presented and compared with distance transform method. Samples with known characteristics generated using a simulation scheme known as µ-randomness were employed to evaluate the accuracy of the method. Electrospun webs of polyvinyl alcohol (PVA were also used to verify the applicability of the method on real samples. Since direct tracking as well as distance transform require binary input images, micrographs of the electrospun webs obtained from Scanning Electron Microscopy (SEM were first converted to black and white using local thresholding. Direct tracking resulted in more accurate estimations of fiber diameter for simulated images as well as electrospun webs suggesting the usefulness of the method for electrospun nanofiber diameter measurement.

  7. NEOWISE Reactivation Mission Year Two: Asteroid Diameters and Albedos

    CERN Document Server

    Nugent, C R; Bauer, J; Cutri, R M; Kramer, E A; Grav, T; Masiero, J; Sonnett, S; Wright, E L

    2016-01-01

    The Near-Earth Object Wide-Field Infrared Survey Explorer (NEOWISE) mission continues to detect, track, and characterize minor planets. We present diameters and albedos calculated from observations taken during the second year since the spacecraft was reactivated in late 2013. These include 207 near-Earth asteroids and 8,885 other asteroids. $84\\%$ of the near-Earth asteroids did not have previously measured diameters and albedos by the NEOWISE mission. Comparison of sizes and albedos calculated from NEOWISE measurements with those measured by occultations, spacecraft, and radar-derived shapes shows accuracy consistent with previous NEOWISE publications. Diameters and albedos fall within $ \\pm \\sim20\\%$ and $\\pm\\sim40\\%$, 1-sigma, respectively, of those measured by these alternate techniques. NEOWISE continues to preferentially discover near-Earth objects which are large ($>100$ m), and have low albedos.

  8. Optical coating uniformity of 200mm (8") diameter precut wafers

    Science.gov (United States)

    Burt, Travis C.; Fisher, Mark; Brown, Dean; Troiani, David

    2017-02-01

    Automated spectroscopic profiling (mapping) of a 200 mm diameter near infrared high reflector (centered at 1064 nm) are presented. Spatial resolution at 5 mm or less was achieved using a 5 mm × 1.5 mm monochromatic beam. Reflection changes of 1.0% across the wafer diameter were observed under s-polarized and p- polarized conditions. Redundancy was established for each chord by re-measuring the center of the wafer and reproducibility of approximately platform for angles of incidence in the range 5°stream processing.

  9. On the diameter of the Kronecker product graph

    CERN Document Server

    Hu, Fu-Tao

    2012-01-01

    Let $G_1$ and $G_2$ be two undirected nontrivial graphs. The Kronecker product of $G_1$ and $G_2$ denoted by $G_1\\otimes G_2$ with vertex set $V(G_1)\\times V(G_2)$, two vertices $x_1x_2$ and $y_1y_2$ are adjacent if and only if $(x_1,y_1)\\in E(G_1)$ and $(x_2,y_2)\\in E(G_2)$. This paper presents a formula for computing the diameter of $G_1\\otimes G_2$ by means of the diameters and primitive exponents of factor graphs.

  10. NEOWISE REACTIVATION MISSION YEAR ONE: PRELIMINARY ASTEROID DIAMETERS AND ALBEDOS

    Energy Technology Data Exchange (ETDEWEB)

    Nugent, C. R.; Cutri, R. M. [Infrared Processing and Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States); Mainzer, A.; Masiero, J.; Bauer, J.; Kramer, E.; Sonnett, S.; Stevenson, R. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Grav, T. [Planetary Science Institute, Tucson, AZ (United States); Wright, E. L., E-mail: cnugent@ipac.caltech.edu [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States)

    2015-12-01

    We present preliminary diameters and albedos for 7956 asteroids detected in the first year of the NEOWISE Reactivation mission. Of those, 201 are near-Earth asteroids and 7755 are Main Belt or Mars-crossing asteroids. 17% of these objects have not been previously characterized using the Near-Earth Object Wide-field Infrared Survey Explorer, or “NEOWISE” thermal measurements. Diameters are determined to an accuracy of ∼20% or better. If good-quality H magnitudes are available, albedos can be determined to within ∼40% or better.

  11. Mixed effect models for predicting breast height diameter from stump diameter of Oriental beech in Göldağ

    Directory of Open Access Journals (Sweden)

    Ilker Ercanli

    2015-06-01

    Full Text Available Diameter at breast height (DBH is the simplest, most common and most important tree dimension in forest inventory and is closely correlated with wood volume, height and biomass. In this study, a number of linear and nonlinear models predicting diameter at breast height from stump diameter were developed and evaluated for Oriental beech (Fagus orientalisLipsky stands located in the forest region of Ayancık, in the northeast of Turkey. A set of 1,501 pairs of diameter at breast height-stump measurements, originating from 70 sample plots of even-aged Oriental beech stands, were used in this study. About 80 % of the otal data (1,160 trees in 55 sample plots was used to fit a number of linear and nonlinear model parameters; the remaining 341 trees in 15 sample plots were randomly reserved for model validation and calibration response. The power model data set was found to produce the most satisfactory fits with the Adjusted Coefficient of Determination, R2adj (0.990, Root Mean Square Error, RMSE (1.25, Akaike’s Information Criterion, AIC (3820.5, Schwarz’s Bayesian Information Criterion, BIC (3837.2, and Absolute Bias (1.25. The nonlinear mixed-effect modeling approach for power model with R2adj(0.993, AIC (3598, BIC (3610.1, Absolute Bias (0.73 and RMSE (1.04 provided much better fitting and precise predictions for DBH from stump diameter than the conventional nonlinear fixed effect model structures for this model. The calibration response including tree DBH and stump diameter measurements of the four largest trees in a calibrated sample plot in calibration produced the highest Bias, -5.31 %, and RMSE, -6.30 %, the greatest reduction percentage.

  12. Uncertainty budget for optical coordinate measurements of circle diameter

    DEFF Research Database (Denmark)

    Morace, Renate Erica; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2004-01-01

    An uncertainty analysis for circle diameter measurements using a coordinate measuring machine (CMM) equipped with an optical probe is presented in this paper. A mathematical model for data evaluation and uncertainty assessment was formulated in accordance with Guide to the Expression of Uncertain...

  13. Experimental study on strain sensing by small-diameter FBG

    Science.gov (United States)

    Liu, Rong-mei; Li, Qiufeng; Zhu, Lujia; Liang, Dakai

    2016-11-01

    Fiber Bragg grating (FBG) sensors were attractive in various fields for structural health monitoring. Because of their accurate performance and real time response, embedded FBG sensors are promising for strain monitoring in composite materials. As an optical fiber sensor was embedded inside a composite, interface would form around the embedded optical fiber and the host polymer composite. In order to study the influence of the embedded optical fiber to the mechanical character, finite elemental analysis was applied to study the stress distribution inside the composite. Keeping the resin rich area the same size, laminates with optical fibers in different diameters, which were 250 and 125 micrometers, were analyzed. The simulation results represent that stress singularity would occur around the embedded optical fiber. The singularity value for the laminate with optical fiber at 250 micrometer was higher than that with optical fiber at 125 micrometer. Micro- cracks would arise at the stress singularity point. Therefore, the optical fiber in smaller diameter was preferred since the mechanical strength could be higher. Four points bending test was carried out on a steel beam with a small-diameter FBG on the bottom surface. Besides, a strain gauge was stuck on bottom to validate the monitoring results by FBG sensor. The tested results indicated that the strain monitoring results by the small-diameter FBG sensor almost identical with the theoretical ones and what recorded by strain gauge. The maximum testing error for the designed FBG is less than 2% compared with the theoretical one.

  14. Predicted and observed finger diameters in field soils

    NARCIS (Netherlands)

    Ritsema, C.J.; Steenhuis, T.S.; Parlange, J.Y.; Dekker, L.W.

    1996-01-01

    Wetting front instability resulting in fingered flow has been found in both wettable and non-wettable soils. Laboratory research has resulted in a number of expressions for finger diameter. The applicability of one of these equations was tested for three soils where detailed soil moisture contents w

  15. Pupil diameter covaries with BOLD activity in human locus coeruleus.

    Science.gov (United States)

    Murphy, Peter R; O'Connell, Redmond G; O'Sullivan, Michael; Robertson, Ian H; Balsters, Joshua H

    2014-08-01

    The locus coeruleus-noradrenergic (LC-NA) neuromodulatory system has been implicated in a broad array of cognitive processes, yet scope for investigating this system's function in humans is currently limited by an absence of reliable non-invasive measures of LC activity. Although pupil diameter has been employed as a proxy measure of LC activity in numerous studies, empirical evidence for a relationship between the two is lacking. In the present study, we sought to rigorously probe the relationship between pupil diameter and BOLD activity localized to the human LC. Simultaneous pupillometry and fMRI revealed a relationship between continuous pupil diameter and BOLD activity in a dorsal pontine cluster overlapping with the LC, as localized via neuromelanin-sensitive structural imaging and an LC atlas. This relationship was present both at rest and during performance of a two-stimulus oddball task, with and without spatial smoothing of the fMRI data, and survived retrospective image correction for physiological noise. Furthermore, the spatial extent of this pupil/LC relationship guided a volume-of-interest analysis in which we provide the first demonstration in humans of a fundamental characteristic of animal LC activity: phasic modulation by oddball stimulus relevance. Taken together, these findings highlight the potential for utilizing pupil diameter to achieve a more comprehensive understanding of the role of the LC-NA system in human cognition.

  16. Rowlinson’s concept of an effective hard sphere diameter

    Science.gov (United States)

    Henderson, Douglas

    2010-01-01

    Attention is drawn to John Rowlinson’s idea that the repulsive portion of the intermolecular interaction may be replaced by a temperature-dependent hard sphere diameter. It is this approximation that made the development of perturbation theory possible for realistic fluids whose intermolecular interactions have a steep, but finite, repulsion at short separations. PMID:20953320

  17. Rowlinson's concept of an effective hard sphere diameter.

    Science.gov (United States)

    Henderson, Douglas

    2010-01-01

    Attention is drawn to John Rowlinson's idea that the repulsive portion of the intermolecular interaction may be replaced by a temperature-dependent hard sphere diameter. It is this approximation that made the development of perturbation theory possible for realistic fluids whose intermolecular interactions have a steep, but finite, repulsion at short separations.

  18. FACES WITH LARGE DIAMETER ON THE SYMMETRICAL TRAVELING SALESMAN POLYTOPE

    NARCIS (Netherlands)

    SIERKSMA, G; TIJSSEN, GA

    1992-01-01

    This paper deals with the symmetric traveling salesman polytope and contains three main theorems. The first one gives a new characterization of (non)adjacency. Based on this characterization a new upper bound for the diameter of the symmetric traveling salesman polytope (conjectured to be 2 by M. Gr

  19. Definition of Beam Diameter for Electron Beam Welding

    Energy Technology Data Exchange (ETDEWEB)

    Burgardt, Paul [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pierce, Stanley W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dvornak, Matthew John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    It is useful to characterize the dimensions of the electron beam during process development for electron beam welding applications. Analysis of the behavior of electron beam welds is simplest when a single number can be assigned to the beam properties that describes the size of the beam spot; this value we generically call the “beam diameter”. This approach has worked well for most applications and electron beam welding machines with the weld dimensions (width and depth) correlating well with the beam diameter. However, in recent weld development for a refractory alloy, Ta-10W, welded with a low voltage electron beam machine (LVEB), it was found that the weld dimensions (weld penetration and weld width) did not correlate well with the beam diameter and especially with the experimentally determined sharp focus point. These data suggest that the presently used definition of beam diameter may not be optimal for all applications. The possible reasons for this discrepancy and a suggested possible alternative diameter definition is the subject of this paper.

  20. Calibration of Laser Beam Direction for Inner Diameter Measuring Device

    Directory of Open Access Journals (Sweden)

    Tongyu Yang

    2017-02-01

    Full Text Available The laser triangulation method is one of the most advanced methods for large inner diameter measurement. Our research group proposed a kind of inner diameter measuring device that is principally composed of three laser displacement sensors known to be fixed in the same plane measurement position. It is necessary to calibrate the direction of the laser beams that are emitted by laser displacement sensors because they do not meet the theoretical model accurately. For the purpose of calibrating the direction of laser beams, a calibration method and mathematical model were proposed. The inner diameter measuring device is equipped with the spindle of the machine tool. The laser beams rotate and translate in the plane and constitute the rotary rays which are driven to scan the inner surface of the ring gauge. The direction calibration of the laser beams can be completed by the sensors’ distance information and corresponding data processing method. The corresponding error sources are analyzed and the validity of the method is verified. After the calibration, the measurement error of the inner diameter measuring device reduced from ± 25 μ m to ± 15 μ m and the relative error was not more than 0.011%.

  1. Diameter-dependent conductance of InAs nanowires

    NARCIS (Netherlands)

    Scheffler, M.; Nadj-Perge, S.; Kouwenhoven, L.P.; Borgström, M.T.; Bakkers, E.P.A.M.

    2009-01-01

    Electrical conductance through InAs nanowires is relevant for electronic applications as well as for fundamental quantum experiments. Here, we employ nominally undoped, slightly tapered InAs nanowires to study the diameter dependence of their conductance. By contacting multiple sections of each wire

  2. Asteroid magnitudes, UBV colors, and IRAS albedos and diameters

    Science.gov (United States)

    Tedesco, Edward F.

    1989-01-01

    This paper lists absolute magnitudes and slope parameters for known asteroids numbered through 3318. The values presented are those used in reducing asteroid IR flux data obtained with the IRAS. U-B colors are given for 938 asteroids, and B-V colors are given for 945 asteroids. The IRAS albedos and diameters are tabulated for 1790 asteroids.

  3. A small-diameter NMR logging tool for groundwater investigations.

    Science.gov (United States)

    Walsh, David; Turner, Peter; Grunewald, Elliot; Zhang, Hong; Butler, James J; Reboulet, Ed; Knobbe, Steve; Christy, Tom; Lane, John W; Johnson, Carole D; Munday, Tim; Fitzpatrick, Andrew

    2013-01-01

    A small-diameter nuclear magnetic resonance (NMR) logging tool has been developed and field tested at various sites in the United States and Australia. A novel design approach has produced relatively inexpensive, small-diameter probes that can be run in open or PVC-cased boreholes as small as 2 inches in diameter. The complete system, including surface electronics and various downhole probes, has been successfully tested in small-diameter monitoring wells in a range of hydrogeological settings. A variant of the probe that can be deployed by a direct-push machine has also been developed and tested in the field. The new NMR logging tool provides reliable, direct, and high-resolution information that is of importance for groundwater studies. Specifically, the technology provides direct measurement of total water content (total porosity in the saturated zone or moisture content in the unsaturated zone), and estimates of relative pore-size distribution (bound vs. mobile water content) and hydraulic conductivity. The NMR measurements show good agreement with ancillary data from lithologic logs, geophysical logs, and hydrogeologic measurements, and provide valuable information for groundwater investigations.

  4. Estimating Tree Height-Diameter Models with the Bayesian Method

    Directory of Open Access Journals (Sweden)

    Xiongqing Zhang

    2014-01-01

    Full Text Available Six candidate height-diameter models were used to analyze the height-diameter relationships. The common methods for estimating the height-diameter models have taken the classical (frequentist approach based on the frequency interpretation of probability, for example, the nonlinear least squares method (NLS and the maximum likelihood method (ML. The Bayesian method has an exclusive advantage compared with classical method that the parameters to be estimated are regarded as random variables. In this study, the classical and Bayesian methods were used to estimate six height-diameter models, respectively. Both the classical method and Bayesian method showed that the Weibull model was the “best” model using data1. In addition, based on the Weibull model, data2 was used for comparing Bayesian method with informative priors with uninformative priors and classical method. The results showed that the improvement in prediction accuracy with Bayesian method led to narrower confidence bands of predicted value in comparison to that for the classical method, and the credible bands of parameters with informative priors were also narrower than uninformative priors and classical method. The estimated posterior distributions for parameters can be set as new priors in estimating the parameters using data2.

  5. Real-time precision measuring device of tree diameter growth

    Science.gov (United States)

    Guo, Mingming; Chen, Aijun; Li, Dongsheng; Liu, Nan; Yao, Jingyuan

    2016-01-01

    DBH(diameter at breast height) is an important factor to reflect of the quality of plant growth, also an important parameter indispensable in forest resources inventory and forest carbon sink, the accurate measurement of DBH or not is directly related to the research of forest resources inventory and forest carbon sink. In this paper, the principle and the mathematical model of DBH measurement device were introduced, the fixture measuring device and the hardware circuit for this tree diameter were designed, the measurement software programs were compiled, and the precision measuring device of tree diameter growth was developed. Some experiments with Australia fir were conducted. Based on experiment data, the correlations among the DBH variation of Australian fir, the environment temperature, air humility and PAR(photosynthetically active radiation) were obtained. The effects of environmental parameters (environment temperature, air humility and PAR) on tree diameter were analyzed. Experimental results show that there is a positive correlation between DBH variation of Australian fir and environment temperature, a negative correlation between DBH variation of Australian fir and air humility , so is PAR.

  6. The Angular Diameter and Fundamental Parameters of Sirius A

    CERN Document Server

    Davis, J; North, J R; Robertson, J G; Tango, W J; Tuthill, P G

    2010-01-01

    The Sydney University Stellar Interferometer (SUSI) has been used to make a new determination of the angular diameter of Sirius A. The observations were made at an effective wavelength of 694.1 nm and the new value for the limb-darkened angular diameter is 6.048 +/- 0.040mas (+/-0.66%). This new result is compared with previous measurements and is found to be in excellent agreement with a conventionally calibrated measurement made with the European Southern Observatory's Very Large Telescope Interferometer (VLTI) at 2.176 microns (but not with a second globally calibrated VLTI measurement). A weighted mean of the SUSI and first VLTI results gives the limb-darkened angular diameter of Sirius A as 6.041 +/- 0.017mas (+/-0.28%). Combination with the Hipparcos parallax gives the radius equal to 1.713 +/- 0.009R_sun. The bolometric flux has been determined from published photometry and spectrophotometry and, combined with the angular diameter, yields the emergent flux at the stellar surface equal to (5.32+/- 0.14)...

  7. Observations on placentome diameters in gestating West African ...

    African Journals Online (AJOL)

    ADEYEYE

    2015-09-09

    Sep 9, 2015 ... Department of Veterinary Surgery and Reproduction, University of Ibadan, Ibadan, Nigeria ... This study investigated the effect of experimental Trypanosoma brucei infection on the placentome diameter (PD) ... symptoms/clinical signs in female mammalian ..... Global Library Women's Medicine, London,.

  8. Small-diameter trees used for chemithermomechanical pulps.

    Science.gov (United States)

    Gary C. Myers; R. James. Barbour; Said M. Abubakr

    1999-01-01

    During the course of restoring and maintaining forest ecosystem health and function in the western interior of the United States, many small-diameter stems are removed from densely stocked stands. In general, these materials are considered nonusable or underutilized. Information on the properties of these resources is needed to help managers understand when timber...

  9. Processing of fine-diameter continuous mullite fibers

    Energy Technology Data Exchange (ETDEWEB)

    Al-Assafi, S.; Cruse, T.; Simmons, J.H. [Univ. of Florida, Gainesville, FL (United States)] [and others

    1994-12-31

    Fine-diameter, continuous mullite fibers were fabricated by sol-gel processing using two different chelating agents on weight loss behavior, mullite formation, and sintered fiber microstructure were examined. The molar ratio, R, of chelating agent to alumina precursor in the sol was varied in order to optimize continuous spinning conditions. The importance of aging conditions on the sintered fiber density was demonstrated.

  10. Bipartite Diametrical Graphs of Diameter 4 and Extreme Orders

    Directory of Open Access Journals (Sweden)

    Salah Al-Addasi

    2008-01-01

    in which this upper bound is attained, this graph can be viewed as a generalization of the Rhombic Dodecahedron. Then we show that for any ≥2, the graph (2,2 is the unique (up to isomorphism bipartite diametrical graph of diameter 4 and partite sets of cardinalities 2 and 2, and hence in particular, for =3, the graph (6,8 which is just the Rhombic Dodecahedron is the unique (up to isomorphism bipartite diametrical graph of such a diameter and cardinalities of partite sets. Thus we complete a characterization of -graphs of diameter 4 and cardinality of the smaller partite set not exceeding 6. We prove that the neighborhoods of vertices of the larger partite set of (2,2 form a matroid whose basis graph is the hypercube . We prove that any -graph of diameter 4 is bipartite self complementary, thus in particular (2,2. Finally, we study some additional properties of (2,2 concerning the order of its automorphism group, girth, domination number, and when being Eulerian.

  11. Multi-diameter pigging: factors affecting the design and selection of pigging tools for multi-diameter pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, Karl [Pipeline Engineering and Supply Co. Ltd., Richmond, NY (United States)

    2009-07-01

    This paper will consider the process involved in pigging tool selection for pipelines with two or more significant internal diameters which require pigging tools capable of negotiating the different internal diameters whilst also carrying out the necessary pipeline cleaning operation. The paper will include an analysis of pipeline features that affect pigging tool selection and then go on to look at other variables that determine the pigging tool design; this will include a step by step guide outlining how the tool is designed, the development of prototype pigs and the importance of testing and validation prior to final deployment in operational pigging programmes. (author)

  12. Vertebral Artery Diameter and Flow: Nature or Nurture.

    Science.gov (United States)

    Tarnoki, Adam Domonkos; Fejer, Bence; Tarnoki, David Laszlo; Littvay, Levente; Lucatelli, Pierleone; Cirelli, Carlo; Fanelli, Fabrizio; Sacconi, Beatrice; Fagnani, Corrado; Medda, Emanuela; Farina, Filippo; Meneghetti, Giorgio; Horvath, Tamas; Pucci, Giacomo; Schillaci, Giuseppe; Stazi, Maria Antonietta; Baracchini, Claudio

    2017-09-01

    In contrast with the carotid arteries, the vertebral arteries (VAs) show considerable variation in length, caliber, and vessel course. This study investigated whether the variation in diameter and flow characteristics of the VAs might be inherited. A total of 172 Italian twins from Padua, Perugia, and Terni (54 monozygotic, 32 dizygotic) recruited from the Italian Twin Registry underwent B-mode and pulsed-wave Doppler ultrasound assessment of their VAs. VA diameters, peak systolic velocity (PSV) and end diastolic velocity (EDV) were assessed at the level of a horizontal V2 segment. Univariate quantitative genetic modeling was performed. Fourteen percent of the sample had VA hypoplasia. Within pair correlation in monozygotic twins was higher than in dizygotics (.552 vs. .229) for VA diameter. Age- and sex-adjusted genetic effect, under the most parsimonious model, accounted for 54.7% (95% CI: 42.2-69.1%) of the variance of VA diameter, and unshared environmental effect for 45.3% (95% CI: 30.9-57.8%). No heritability was found for the PSV of VA, but shared (34.1%; 95% CI: 16.7-53.7%) and unshared (65.9%; 95% CI: 45.9-83.1%) environmental factors determined the variance. EDV of VA is moderately genetically influenced (42.4%; 95% CI: 16.1-64.9%) and also determined by the unshared environment (57.6%; 95% CI: 34.7-83.7%). The diameter of the VAs is moderately genetically determined. Different factors influence the PSV and EDV of VAs, which may highlight the complex hemodynamic background of VA flow and help to understand the vertebral flow anomalies found by ultrasound. Copyright © 2017 by the American Society of Neuroimaging.

  13. Stand diameter distribution modelling and prediction based on Richards function.

    Directory of Open Access Journals (Sweden)

    Ai-guo Duan

    Full Text Available The objective of this study was to introduce application of the Richards equation on modelling and prediction of stand diameter distribution. The long-term repeated measurement data sets, consisted of 309 diameter frequency distributions from Chinese fir (Cunninghamia lanceolata plantations in the southern China, were used. Also, 150 stands were used as fitting data, the other 159 stands were used for testing. Nonlinear regression method (NRM or maximum likelihood estimates method (MLEM were applied to estimate the parameters of models, and the parameter prediction method (PPM and parameter recovery method (PRM were used to predict the diameter distributions of unknown stands. Four main conclusions were obtained: (1 R distribution presented a more accurate simulation than three-parametric Weibull function; (2 the parameters p, q and r of R distribution proved to be its scale, location and shape parameters, and have a deep relationship with stand characteristics, which means the parameters of R distribution have good theoretical interpretation; (3 the ordinate of inflection point of R distribution has significant relativity with its skewness and kurtosis, and the fitted main distribution range for the cumulative diameter distribution of Chinese fir plantations was 0.4∼0.6; (4 the goodness-of-fit test showed diameter distributions of unknown stands can be well estimated by applying R distribution based on PRM or the combination of PPM and PRM under the condition that only quadratic mean DBH or plus stand age are known, and the non-rejection rates were near 80%, which are higher than the 72.33% non-rejection rate of three-parametric Weibull function based on the combination of PPM and PRM.

  14. Stand diameter distribution modelling and prediction based on Richards function.

    Science.gov (United States)

    Duan, Ai-guo; Zhang, Jian-guo; Zhang, Xiong-qing; He, Cai-yun

    2013-01-01

    The objective of this study was to introduce application of the Richards equation on modelling and prediction of stand diameter distribution. The long-term repeated measurement data sets, consisted of 309 diameter frequency distributions from Chinese fir (Cunninghamia lanceolata) plantations in the southern China, were used. Also, 150 stands were used as fitting data, the other 159 stands were used for testing. Nonlinear regression method (NRM) or maximum likelihood estimates method (MLEM) were applied to estimate the parameters of models, and the parameter prediction method (PPM) and parameter recovery method (PRM) were used to predict the diameter distributions of unknown stands. Four main conclusions were obtained: (1) R distribution presented a more accurate simulation than three-parametric Weibull function; (2) the parameters p, q and r of R distribution proved to be its scale, location and shape parameters, and have a deep relationship with stand characteristics, which means the parameters of R distribution have good theoretical interpretation; (3) the ordinate of inflection point of R distribution has significant relativity with its skewness and kurtosis, and the fitted main distribution range for the cumulative diameter distribution of Chinese fir plantations was 0.4∼0.6; (4) the goodness-of-fit test showed diameter distributions of unknown stands can be well estimated by applying R distribution based on PRM or the combination of PPM and PRM under the condition that only quadratic mean DBH or plus stand age are known, and the non-rejection rates were near 80%, which are higher than the 72.33% non-rejection rate of three-parametric Weibull function based on the combination of PPM and PRM.

  15. Arteriolar Diameters in Glaucomatous Eyes with Single-Hemifield Damage.

    Science.gov (United States)

    Russo, Andrea; Costagliola, Ciro; Rizzoni, Damiano; Ghilardi, Nausica; Turano, Raffaele; Semeraro, Francesco

    2016-05-01

    To examine the association between retinal arteriolar caliber and lumen, retinal sensitivity (RS), and retinal nerve fiber layer (RNFL) thickness in glaucomatous eyes with single-hemifield loss. We conducted a prospective, nonrandomized, case-control study of 20 eyes of 20 patients with glaucoma with visual field damage confined to a single hemifield. The control group was composed of 20 eyes of 20 normal subjects. For all the eyes, we performed optical coherence tomography to assess the RNFL and standard automated perimetry to evaluate RS. External and internal arteriolar diameters were assessed in vivo using scanning laser Doppler flowmetry. The RNFL was significantly thinner in glaucomatous eyes than in normal eyes (p < 0.001). In glaucomatous eyes, a positive correlation between sectorial RNFL thickness and the corresponding external and internal arteriolar diameters was found (r = 0.43, p = 0.05; r = 0.63, p = 0.003, respectively). The internal arteriolar diameter significantly correlated with RS in the corresponding abnormal hemifield (r = 0.44, p = 0.04). Compared with the normal hemifield, the internal arteriolar diameter, RNFL thickness, and RS were significantly reduced, whereas the external arteriolar diameter was unchanged in the abnormal hemifield. In glaucomatous eyes with single-hemifield damage, attenuation of retinal vessels was associated with a thinner RNFL and reduced RS. Moreover, a narrower lumen with increased wall-to-lumen ratio was found in the abnormal hemifield, supporting the hypothesis that vessel narrowing is likely secondary to a lower demand for blood flow in the glaucomatous areas of the retina.

  16. Measurement error in CT assessment of appendix diameter

    Energy Technology Data Exchange (ETDEWEB)

    Trout, Andrew T.; Towbin, Alexander J. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, MLC 5031, Cincinnati, OH (United States); Zhang, Bin [Cincinnati Children' s Hospital Medical Center, Department of Biostatistics and Epidemiology, Cincinnati, OH (United States)

    2016-12-15

    Appendiceal diameter continues to be cited as an important criterion for diagnosis of appendicitis by computed tomography (CT). To assess sources of error and variability in appendiceal diameter measurements by CT. In this institutional review board-approved review of imaging and medical records, we reviewed CTs performed in children <18 years of age between Jan. 1 and Dec. 31, 2010. Appendiceal diameter was measured in the axial and coronal planes by two reviewers (R1, R2). One year later, 10% of cases were remeasured. For patients who had multiple CTs, serial measurements were made to assess within patient variability. Measurement differences between planes, within and between reviewers, within patients and between CT and pathological measurements were assessed using correlation coefficients and paired t-tests. Six hundred thirty-one CTs performed in 519 patients (mean age: 10.9 ± 4.9 years, 50.8% female) were reviewed. Axial and coronal measurements were strongly correlated (r = 0.92-0.94, P < 0.0001) with coronal plane measurements significantly larger (P < 0.0001). Measurements were strongly correlated between reviewers (r = 0.89-0.9, P < 0.0001) but differed significantly in both planes (axial: +0.2 mm, P=0.003; coronal: +0.1 mm, P=0.007). Repeat measurements were significantly different for one reviewer only in the axial plane (0.3 mm difference, P<0.05). Within patients imaged multiple times, measured appendix diameters differed significantly in the axial plane for both reviewers (R1: 0.5 mm, P = 0.031; R2: 0.7 mm, P = 0.022). Multiple potential sources of measurement error raise concern about the use of rigid diameter cutoffs for the diagnosis of acute appendicitis by CT. (orig.)

  17. Acute Dermal Irritation Study of Six Jet Fuels in New Zealand White Rabbits: Comparison of Four Bio-Based Jet Fuels with Two Petroleum JP-8 Fuels

    Science.gov (United States)

    2014-02-01

    alternative fuel, ReadiJet, refers to a Renewable, Aromatic, Drop-in (abbreviated Readi) fuel produced from plant oils or animal fats through a catalytic...camelina plant, tallow, animal fats and oils , algae) were tested in this assay by Mattie et al. (2013) and Sterner et al. (2014). HEFA-SPKs were...Appraisal of the Safety of Chemicals in Foods, Drugs and Cosmetics. Dermal Toxicity , pp. 46-59. Assoc. of Food and Drug Officials of the U.S., Topeka

  18. The Preignition and Autoignition Oxidation of Alternatives to Petroleum Derived JP-8 and their Surrogate Components in a Pressurized Flow Reactor and Single Cylinder Research Engine

    Science.gov (United States)

    2009-09-01

    designs such as HCCI engines , where ignition relies on the chemistry of the fuel. An initial mixture of 59.4% n-decane/40.6% iso-octane was...Octane Oxidation for HCCI Engines . Fuel, Vol. 85, 2593-2604. Koert, D. N., N. P. Cernansky. (1992). A Flow Reactor for the Study of...Reactor and Single Cylinder Research Engine A Thesis Submitted to the Faculty of Drexel University by Matthew S. Kurman in partial

  19. Environmental Assessment for the Replacement of the JP-8 Transfer Pipeline between the 6000 Area and 400 Area at Tyndall Air Force Base Bay County, Florida

    Science.gov (United States)

    2012-09-01

    lakes, developed naturally as a result of coastal land processes. There are some 45 intra-dune waterbodies. Salinities and water levels of some of...cockaded Woodpecker Picoides borealis E SSC Mature Pine Forests Black Skimmer Rhychops niger SSC Shoreline Least Tern Sterna antillarum T Barrier

  20. Propulsion and Power Rapid Response Research and Development (R&D) Support. Task Order 0011: JP-8+100 Development History and Maintenance Benefits

    Science.gov (United States)

    2010-06-01

    Damaged or Failed Buckets 152 Turbine Nozzle Failure 153 Turbine Damage Due To Material Failure 175 Adverse EGT-TIT Trend 176 Adverse RPM Trend 182...in Figure 11 and the coke that has fallen off when the tube was removed from the housing. The suction of the venturi attempts to drain all the fuel

  1. Environmental Life Cycle Assessment of Coal-Biomass to Liquid Jet Fuel Compared to Petroleum-Derived JP-8 Jet Fuel

    Science.gov (United States)

    2010-03-01

    other chemical reactions (e.g., manufacture of cement ). CO2 is also removed from the atmosphere (or “sequestered”) when it is absorbed by plants as...systems and dedicated biomass burners . The advantage of having separate feed systems would be that, if the biomass system becomes inoperable for a

  2. Evaluation of Next Generation Thermal Stability-Improving Additives for JP-8, Phase 2 - Specification, Materials, Filtration, and Fit-For-Purpose Evaluations

    Science.gov (United States)

    2013-12-01

    outside-in for the separators. Both coalescer technologies use glass to generate larger water droplets and Teflon separator screens to repel any water ...mainly to anomalous or nebulous data relating to filtration and water separation. It is recommended that these additives undergo additional filtration... water separation testing and that the results of the testing in this program be combined with any new data to re- evaluate AFRL’s position regarding

  3. Conversion of a Micro, Glow-Ignition, Two-Stroke Engine from Nitromethane-Methanol Blend Fuel to Military Jet Propellant (JP-8)

    Science.gov (United States)

    2012-01-01

    section of air intake assembly solid model; shows hot-wire anemometer probe orientation and venturi shape [25...it the weak link. Added machined flat to motor shaft and a #6-32 UNC cup -point setscrew to coupler on motor end. 2 Coupler spins up threaded...engine shaft Having fixed the motor end, engine end became the weak link. Added machined flat to engine shaft and a #8-32 UNC cup -point setscrew

  4. Environmental Assessment for the Outgrant of Real Estate and Construction of JP-8 Pipeline and Receiving Facility at Travis Air Force Base

    Science.gov (United States)

    2009-11-01

    UST underground storage tank VOC volatile organic compound(s) VRP visibility-reducing particle(s) WABOU West/Annexes/Basewide Operable Unit WWII...these pollutants, as well as hydrogen sulfide (H2S), sulfates, vinyl chloride, and visibility-reducing particles ( VRPs ). 3.2.1.1 Air Pollutants Air...attainment area for CO, NO2, SO2, Pb, and sulfates, and a nonattainment area for PM2.5, PM10, and state 1-hour and 8-hour O3 standards; VRPs and

  5. Aneurysm diameter and proximal aortic neck diameter influence clinical outcome of endovascular abdominal aortic repair : A 4-year EUROSTAR experience

    NARCIS (Netherlands)

    Waasdorp, EJ; de Vries, JPPM; Hobo, R; Leurs, LJ; Buth, J; Moll, FL

    2005-01-01

    Our objective was to evaluate the effect of preoperative aneurysm and aortic neck diameter on clinical outcome after infrarenal abdominal endovascular aneurysm repair (EVAR). Data of patients in the European Collaborators Registry on Stent-Graft Techniques for Abdominal Aortic Aneurysm Repair (EUROS

  6. Tunable diameter electrostatically formed nanowire for high sensitivity gas sensing

    Institute of Scientific and Technical Information of China (English)

    Alex Henning; Nandhini Swaminathan; Andrey Godkin; Gil Shalev; Iddo Amit; Yossi Rosenwaks

    2015-01-01

    We report on an electrostatically formed nanowire (EFN)-based sensor with tunable diameters in the range of 16 nm to 46 nm and demonstrate an EFN- based field-effect transistor as a highly sensitive and robust room temperature gas sensor. The device was carefully designed and fabricated using standard integrated processing to achieve the 16 nm EFN that can be used for sensing without any need for surface modification. The effective diameter for the EFN was determined using Kelvin probe force microscopy accompanied by three- dimensional electrostatic simulations. We show that the EFN transistor is capable of detecting 100 parts per million of ethanol gas with bare SiO2.

  7. Angular diameter distances reconsidered in the Newman and Penrose formalism

    CERN Document Server

    Kling, Thomas P

    2016-01-01

    Using the Newman and Penrose spin coefficient (NP) formalism, we provide a derivation of the Dyer-Roeder equation for the angular diameter distance in cosmological space-times. We show that the geodesic deviation equation written in NP formalism is precisely the Dyer-Roeder equation for a general Friedman-Robertson-Walker (FRW) space-time, and then we examine the angular diameter distance to redshift relation in the case that a flat FRW metric is perturbed by a gravitational potential. We examine the perturbation in the case that the gravitational potential exhibits the properties of a thin gravitational lens, demonstrating how the weak lensing shear and convergence act as source terms for the perturbed Dyer-Roeder equation.

  8. Visual function and retinal vessel diameters during hyperthermia in man

    DEFF Research Database (Denmark)

    Jensen, Bettina Hagström; Bram, Thue; Kappelgaard, Per

    2017-01-01

    laser ophthalmoscopy was used to measure retinal trunk vessel diameters. Assessment was made at baseline, during hyperthermia and after cooling. RESULTS: The induction of a mean increase in core body temperature of 1.02°C was associated with a 7.15-mmHg mean reduction in systolic blood pressure (p ... in cling film, tinfoil and warming blankets. Subsequent cooling was achieved by undressing. Flicker sensitivity (critical flicker fusion frequency) was chosen to assess temporal resolution, while the Freiburg Vision Test was used to determine spatial contrast sensitivity at 1.5 cycles per degree. Scanning...... diameters (CI95 0.96-4.94, p cooling. CONCLUSION: Increased core body temperature was accompanied by improved temporal visual resolution and retinal trunk...

  9. Consequences of the Continuity of the Monic Integer Transfinite Diameter

    CERN Document Server

    Hilmar, Jan

    2007-01-01

    We consider the problem of determining the monic integer transfinite diameter t_M(I)&=&\\lim_{n\\to\\infty}\\inf_{p_n\\in{\\mathcal M_n}}\\supnorm{p_n}{I}^{1/n} for real intervals of length less than 4. We show the $t_M([0,x])$, as a function in $x>0$, is continuous, therefore disproving two conjectures due to Hare and Smyth. Consequently, for $n>2\\in\

  10. A study of the heated length to diameter effects

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Ho; Baek, Won Pil; Chang, Soon Heung [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1997-12-31

    An analytical and experimental investigation has been performed on the heated length-to-diameter effect on critical heat flux exit conditions. A L/D correction factor is developed by applying artificial neural network and conventional regression techniques to the KAIST CHF data base. In addition, experiment is being performed to validate the developed L/D correction factor with independent data. Assessment shows that the developed correction factor is promising for practical applications. 6 refs., 8 figs. (Author)

  11. Retinal vessel diameter changes induced by transient high perfusion pressure

    Institute of Scientific and Technical Information of China (English)

    Yin-Ying; Zhao; Ping-Jun; Chang; Fang; Yu; Yun-E; Zhao

    2014-01-01

    ·AIM: To investigate the effects of transient high perfusion pressure on the retinal vessel diameter and retinal ganglion cells.·METHODS: The animals were divided into four groups according to different infusion pressure and infusion time(60 mm Hg-3min, 60 mm Hg-5min, 100 mm Hg-3min, 100 mm Hg-5min). Each group consisted of six rabbits. The left eye was used as the experimental eye and the right as a control. Retinal vascular diameters were evaluated before, during infusion, immediately after infusion, 5min, 10 min and 30 min after infusion based on the fundus photographs. Blood pressure was monitored during infusion. The eyes were removed after 24 h.Damage to retinal ganglion cell(RGC) was analyzed by histology.·RESULTS: Retina became whiten and papilla optic was pale during perfusion. Measurements showed significant decrease in retinal artery and vein diameter during perfusion in all of the four groups at the proximal of the edge of the optic disc. The changes were significant in the 100 mm Hg-3min group and 100 mm Hg-5min group compared with 60 mm Hg-3min group(P 1=0.025, P 2=0.000).The diameters in all the groups recovered completely after 30 min of reperfusion. The number of RGC)showed no significant changes at the IOP in 100 mm Hg with5 min compared with contralateral untreated eye(P >0.05).·CONCLUSION: Transient fluctuations during infusion lead to temporal changes of retinal vessels, which could affect the retinal blood circulation. The RGCs were not affected by this transient fluctuation. Further studies are necessary to evaluate the effect of pressure during realtime phacoemusification on retinal blood circulation.

  12. Uncertainty budget for optical coordinate measurements of circle diameter

    DEFF Research Database (Denmark)

    Morace, Renate Erica; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2004-01-01

    An uncertainty analysis for circle diameter measurements using a coordinate measuring machine (CMM) equipped with an optical probe is presented in this paper. A mathematical model for data evaluation and uncertainty assessment was formulated in accordance with Guide to the Expression of Uncertainty...... in Measurement (GUM). Various input quantities such as CCD camera resolution, influence of illuminating system, CMM errors etc. were considered in the model function and experimentally investigated....

  13. Pupil Center as a Function of Pupil Diameter

    DEFF Research Database (Denmark)

    Ahmed, Zaheer; Mardanbegi, Diako; Hansen, Dan Witzner

    2016-01-01

    We investigate the gaze estimation error induced by pupil size changes using simulated data. We investigate the influence of pupil diameter changes on estimated gaze point error obtained by two gaze estimation models. Simulation data show that at wider viewing angles and at small eye......-camera distances, error increases with increasing pupil sizes. The maximum error recorded for refracted pupil images is 2.4° of visual angle and 1.5° for non-refracted pupil projections....

  14. THE CUTWIDTH OF TREES WITH DIAMETER AT MOST 4

    Institute of Scientific and Technical Information of China (English)

    LinYixun

    2003-01-01

    The cutwidth problem for a graph G is to embed G into a path Pn such that the maximum number of overlap edges (i. e. , the congestion) is minimized. It is known that the problem for general graphs is NP-hard while it is polynomially solvable for trees. This paper presents an exact formula for the cutwidth of trees with diameter at most 4. A relation with the bandwidth is discussed as well.

  15. Visual function and retinal vessel diameters during hyperthermia in man.

    Science.gov (United States)

    Jensen, Bettina Hagström; Bram, Thue; Kappelgaard, Per; Arvidsson, Henrik; Loskutova, Ekaterina; Munch, Inger Christine; Larsen, Michael

    2016-12-21

    To assess the effect of elevated core body temperature on temporal and spatial contrast sensitivity and retinal vessel diameters. The study included 13 healthy volunteers aged 20-37 years. Core body temperature elevation (target +1.1°C) was induced by wrapping the participants in cling film, tinfoil and warming blankets. Subsequent cooling was achieved by undressing. Flicker sensitivity (critical flicker fusion frequency) was chosen to assess temporal resolution, while the Freiburg Vision Test was used to determine spatial contrast sensitivity at 1.5 cycles per degree. Scanning laser ophthalmoscopy was used to measure retinal trunk vessel diameters. Assessment was made at baseline, during hyperthermia and after cooling. The induction of a mean increase in core body temperature of 1.02°C was associated with a 7.15-mmHg mean reduction in systolic blood pressure (p < 0.01), a 10.6-mmHg mean reduction in diastolic blood pressure (p < 0.01), a mean increase in pulse rate of 36.3 bpm (p < 0.0001), a 2.66% improvement in flicker sensitivity (CI95 1.37-3.94, p < 0.001), a 2.80% increase in retinal artery diameters (CI95 1.09-4.51, p < 0.01) and a 2.95% increase in retinal vein diameters (CI95 0.96-4.94, p < 0.01). There was no detectable effect of temperature on spatial contrast sensitivity. All ocular test parameters returned to baseline levels after cooling. Increased core body temperature was accompanied by improved temporal visual resolution and retinal trunk vessel dilation. The results suggest that hyperthermia is associated with enhanced retinal function and increased retinal metabolism. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  16. PREPARATION AND ADSORBABILITY OF DEXTRAN MICROSPHERES WITH UNIFORM DIAMETER

    Institute of Scientific and Technical Information of China (English)

    Ri-sheng Yao; Wen-xia Gao; Jing Sun; Ya-hua You

    2005-01-01

    The method of preparing uniform dextran microspheres with a narrow diameter distribution was introduced and the adsorbability of these microspheres was evaluated. The microspheres were prepared in W/O microemulsion using 0.5% dextran solution as the aqueous phase and n-hexane as the oil phase. Characteristics of the prepared dextran microspheres were examined with laser light blocking technique, optical microscope and ultraviolet spectrometer. The results show that the prepared dextran microspheres have uniform morphology and narrow diameter distribution, nearly 92% of them having a diameter of 56.6 μm. In vitro evaluation of adsorbability, wet dextran microspheres have good adsorption of 98.32 mg/g of model drug methylene blue in 20.86 mg/L methylene blue solution at 25℃. The adsorption of dried dextran microspheres under the same condition is 132.15 mg/g, which is even higher. And the adsorbability of dextran microspheres has significant relationship with the concentration of methylene blue and temperature. The adsorbability is better at lower temperature and higher concentration of methylene blue.

  17. Effects of Pupil Diameter on Light Detection and Temporal Modulation

    Institute of Scientific and Technical Information of China (English)

    Rachel S Li; Andrew W Siu; Johnny C Liyu; Elice C Chan

    2003-01-01

    Purpose: This study compared the effects of pupil variation on light detection and temporal modulation across the central visual field.Methods:Light detection sensitivity (LDS) and low flickering frequency (6Hz) temporal modulation sensitivity (TMS) of 20 young subjects were measured from the central visual field of the right eyes using an automated perimeter (Medmont M600). The measurements were taken under 3 artificial pupils, I.e. 3 mm, 4.3 mm and 6 mm diameters.The sensitivities were grouped and averaged for different retinal eccentricities(3°, 6°, 10° and 15°).Results:TMS and LDS were reduced with increasing retinal eccentricities( P < 0.001)and decreasing pupil diameters( P < 0.001). TMS collected from all pupil diameters were significantly different from each other( P < 0.001). Similarly, LDS under 3 mm pupil was statistically different from those of 4.3 mm and 6 mm(P < 0.003). Comparison of the hills of vision showed that pupil variation resulted in significantly different slopes (P=0.001).The slopes were also found to be significantly different between TMS and LDS (P=0.012).Conclusions: The data showed that dilated pupil resulted in significantly higher sensitivities than those of smaller pupil for both visual functions. The difference in the slopes of hills of vision also suggested that the variation in retinal illumination affected the visual responses differently at various retinal eccentricitities for TMS and LDS.

  18. Effect of conical nanopore diameter on ion current rectification.

    Science.gov (United States)

    Kovarik, Michelle L; Zhou, Kaimeng; Jacobson, Stephen C

    2009-12-10

    Asymmetric nanoscale conduits, such as conical track-etch pores, rectify ion current due to surface charge effects. To date, most data concerning this phenomenon have been obtained for small nanopores with diameters comparable to the electrical double layer thickness. Here, we systematically evaluate rectification for nanopores in poly(ethylene terephthalate) membranes with tip diameters of 10, 35, 85, and 380 nm. Current-voltage behavior is determined for buffer concentrations from 1 mM to 1 M and pHs 3.4 and 6.7. In general, ion current rectification increases with decreasing tip diameter, with decreasing ionic strength, and at higher pH. Surface charge contributes to increased pore conductivities compared to bulk buffer conductivities, though double layer overlap is not necessary for rectification to occur. Interestingly, the 35 nm pore exhibits a maximum rectification ratio for the 0.01 M buffer at pH 6.7, and the 380 nm pores exhibit nearly diodelike current-voltage curves when initially etched and strong rectification after the ion current has stabilized.

  19. Time-delay Cosmography: Increased Leverage with Angular Diameter Distances

    CERN Document Server

    Jee, Inh; Suyu, Sherry H; Huterer, Dragan

    2015-01-01

    Strong lensing time-delay systems constrain cosmological parameters via the so-called time-delay distance and the angular diameter distance to the lens. In previous studies, only the former information was used. In this paper, we show that the cosmological constraints improve significantly when the latter information is also included. Specifically, the angular diameter distance plays a crucial role in breaking the degeneracy between the curvature of the Universe and the time-varying equation of state of dark energy. Using a mock sample of 55 bright quadruple lens systems based on expectations for ongoing/future imaging surveys, we find that adding the angular diameter distance information to the time-delay distance information and the cosmic microwave background data of Planck improves the constraint on the constant equation of state by 30%, on the time variation in the equation of state by a factor of two, and on the Hubble constant in the flat $\\Lambda$CDM model by a factor of two. Therefore, previous forec...

  20. Time-delay cosmography: increased leverage with angular diameter distances

    Science.gov (United States)

    Jee, I.; Komatsu, E.; Suyu, S. H.; Huterer, D.

    2016-04-01

    Strong lensing time-delay systems constrain cosmological parameters via the so-called time-delay distance and the angular diameter distance to the lens. In previous studies, only the former information was used in forecasting cosmographic constraints. In this paper, we show that the cosmological constraints improve significantly when the latter information is also included. Specifically, the angular diameter distance plays a crucial role in breaking the degeneracy between the curvature of the Universe and the time-varying equation of state of dark energy. Using a mock sample of 55 bright quadruple lens systems based on expectations for ongoing/future imaging surveys, we find that adding the angular diameter distance information to the time-delay distance information and the Planck's measurements of the cosmic microwave background anisotropies improves the constraint on the constant equation of state by 30%, on the time variation in the equation of state by a factor of two, and on the Hubble constant in the flat ΛCDM model by a factor of two. Therefore, previous forecasts for the statistical power of time-delay systems were overly pessimistic, i.e., time-delay systems are more powerful than previously appreciated.

  1. Real-time diameter measurement using diffuse light

    Science.gov (United States)

    Luo, Xiaohe; Hui, Mei; Zhu, Qiudong; Wang, Shanshan

    2016-09-01

    A method for on-line rapid determination of the diameter of metallic cylinder is introduced in this paper. Under the radiation of diffuse light, there is a bright area close to the margin of metallic cylinder, and the method of this paper is based on the intensity distribution of the bright area. In this paper, with the radiation by a diffuse plane light with special shape, we present the relation expression of the distance between the peak point and the real edge of the cylinder and the distance between the diffuse light and the pinhole aperture of the camera. With the expression, the diameter of the cylinder to be measured can be calculated. In the experiments, monochromatic LED uniting with ground glass forms the diffuse light source, then the light irradiates the tested cylinder. After the cylinder, we use a lens with a front pinhole stop to choose the light into CMOS, then a computer is used to analyze images and export the measurement results. The measuring system using this method is very easily implemented, so it can realize the on-line rapid measurement. Experimental results are presented for six metallic cylinders with the diameter in 5 18mm range and roughness in Ra- 0.02um, and the precision reaches 3um.

  2. Effects of Diameter on Initial Stiffness of P-Y Curves for Large-Diameter Piles in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Ibsen, Lars Bo; Augustesen, Anders Hust

    2010-01-01

    For offshore wind turbines, monopile foundations with diameters of 4–6m are often employed. The Winkler model approach, where the soil resistance is modelled as uncoupled springs with spring stiffness’ given by p-y curves, is traditionally employed for the design of monopiles. However, this metho...... analyses by means of the commercial program FLAC3D incorporating a Mohr-Coulomb failure criterion. The numerical model is validated with laboratory tests in a pressure tank at Aalborg University....

  3. Piston diameter in stapes surgery. Does it have a bearing?

    Directory of Open Access Journals (Sweden)

    Neha Gupta

    2014-01-01

    Full Text Available Aims and Objectives: This prospective randomized controlled trial was done to study the effect of piston diameter on hearing outcomes after stapedotomy. Materials and Methods: All the patients diagnosed to have otosclerosis were included in the study. A total of 52 patients were studied ranging in age from 18 to 50 years. The subjects were randomized into two groups, that is, 0.4 mm piston (group A and 0.6 mm piston (group B. The subjects were taken up for small fenestra stapedotomy using either a 0.4 or 0.6 mm piston. The main outcome measures were hearing improvement, air-bone gap closure, and overclosure of air-bone gap. Results: There was no statistical difference in hearing improvement in two different piston diameters, 0.4 and 0.6 mm at speech frequencies. In group A, the air-bone gap improvement in the third follow-up was not significant (P > 0.05, whereas group B showed a statistically significant improvement (P = 0.003. The mean overclosure of air-bone gap was better in patients with 0.4 mm piston at speech frequencies and also at 250 Hz. Significantly, overclosure of air-bone gap at higher frequencies (4 and 8 KHz was seen only with a smaller sized piston. (0.4 mm. Discussion: We analyzed the effect of piston diameter on the hearing results after small fenestra stapedotomy by using similar surgical procedure and similar prosthesis in all patients. Conclusion: There is evidence to suggest that 0.4 mm piston may be better suited for providing optimum hearing results.

  4. A solar cycle lengthwise series of solar diameter measurements

    Science.gov (United States)

    Penna, J. L.; Andrei, A. H.; Boscardin, S. C.; Neto, E. Reis; d'Ávila, V. A.

    2010-02-01

    The measurements of the solar photospheric diameter rank among the most difficult astronomic observations. Reasons for this are the fuzzy definition of the limb, the SNR excess, and the adverse daytime seeing condition. As a consequence there are very few lengthy and consistent time series of such measurements. Using modern techniques, just the series from the IAG/USP and from Calern/OCA span more than one solar cycle. The Rio de Janeiro Group observations started in 1997, and therefore in 2008 one complete solar cycle time span can be analyzed. The series shares common principles of observation and analysis with the ones afore mentioned, and it is complementary on time to them. The distinctive features are the larger number of individual points and the improved precision. The series contains about 25,000 single observations, evenly distributed on a day-by-day basis. The typical error of a single observation is half an arc-second, enabling us to investigate variations at the expected level of tens of arc-second on a weekly basis. These features prompted to develop a new methodology for the investigation of the heliophysical scenarios leading to the observed variations, both on time and on heliolatitude. The algorithms rely on running averages and time shifts to derive the correlation and statistical incertitude for the comparison of the long term and major episodes variations of the solar diameter against activity markers. The results bring support to the correlation between the diameter variation and the solar activity, but evidentiating two different regimens for the long term trend and the major solar events.

  5. Mesiodistal crown diameters of permanent dentition in schoolchildren from Lima

    OpenAIRE

    Pineda-Mejia, Martha; Departamento Académico de Estomatología Rehabilitadora, Facultad Odontología de la Universidad Nacional Mayor de San Marco, Perú.; Petkova- Gueorguieva, Marieta; Facultad Odontología de la Universidad Nacional Mayor de San Marcos.

    2015-01-01

    The purpose of this study was to determine the size of mesiodistal diameters of permanent teeth in a school population of the city of Lima, to analyze the differences between homologous teeth, sexual dimorphism of permanent teeth as well as the degree of variability of the measurements. Methodology: The study was conducted on 400 students of mestizos (200 men and 200 women) 10 to 12 years, from three schools in the districts of la Victoria and Barrios Altos, Lima city. The procedure was perfo...

  6. Economic strategies of plant absorptive roots vary with root diameter

    Science.gov (United States)

    Kong, D. L.; Wang, J. J.; Kardol, P.; Wu, H. F.; Zeng, H.; Deng, X. B.; Deng, Y.

    2016-01-01

    Plant roots typically vary along a dominant ecological axis, the root economics spectrum, depicting a tradeoff between resource acquisition and conservation. For absorptive roots, which are mainly responsible for resource acquisition, we hypothesized that root economic strategies differ with increasing root diameter. To test this hypothesis, we used seven plant species (a fern, a conifer, and five angiosperms from south China) for which we separated absorptive roots into two categories: thin roots (thickness of root cortex plus epidermis perspective on our understanding of the root economics spectrum.

  7. On the Connectedness and Diameter of a Geometric Johnson Graph

    CERN Document Server

    Bautista-Santiago, Crevel; Fabila-Monroy, Ruy; Flores-Peñaloza, David; González-Aguilar, Hernán; Lara, Dolores; Sarmiento, Eliseo; Urrutia, Jorge

    2012-01-01

    Let $P$ be a set of $n$ points in general position in the plane. A subset $I$ of $P$ is called an \\emph{island} if there exists a convex set $C$ such that $I = P \\cap C$. In this paper we define the \\emph{generalized island Johnson graph} of $P$ as the graph whose vertex consists of all islands of $P$ of cardinality $k$, two of which are adjacent if their intersection consists of exactly $l$ elements. We show that for large enough values of $n$, this graph is connected, and give upper and lower bounds on its diameter.

  8. A Study of Spiral Tap with Large Diameter

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The design and manufacture of spiral tap yet are in r esearch stage at present. This paper mainly introduces how to calculate its geom etric parameters and scientific selection of them with vector method. In additio n, an empiric formula of the tool life of spiral tap with large diameter is esta blished by method of correlation. The practice of design, manufacture and applying proves the advantage of spiral tap by the comparison between the spiral tap and common tap with same size. In the application of...

  9. Impact damage in small diameter graphite/epoxy composite struts

    Science.gov (United States)

    Chen, G.-S.; Bidinger, G. M.; Cho, S.; Lou, M. C.

    1992-01-01

    An investigation was performed to study impact induced damage in small-diameter struts made of a composite material with a brittle matrix system. The major focus is on characterizing the impact behavior associated with the barely visible damage. An experimental procedure including ultrasonic inspection, instrumented impact testing, and delamination buckling and residual strength measurements is presented. From the ultrasonic inspection, it is found that for the strut specimens under investigation, the impact energy level for barely visible damage threshold is above that of the internal damage threshold. A 60- to 65-percent reduction in compressive strength was typical for struts subjected to the barely visible impact damage threshold.

  10. Twist Neutrality and the Diameter of the Nucleosome Core Particle

    DEFF Research Database (Denmark)

    Bohr, Jakob; Olsen, Kasper

    2012-01-01

    The diameter of the nucleosome core particle is the same for all the eukaryotes. Here we discuss the possibility that this selectiveness is consistent with a propensity for twist neutrality, in particular, for the double helical DNA to stay rotationally neutral when strained. Reorganization of DNA...... cannot be done without some level of temporal tensile stress, and as a consequence chiral molecules, such as helices, will twist under strain. The requirement that the nucleosome, constituting the nucleosome core particle and linker DNA, has a vanishing strain-twist coupling leads to a requirement...

  11. Aharonov—Bohm Oscillations in Small Diameter Bi Nanowires

    Science.gov (United States)

    Konopko, L.

    The Aharonov-Bohm effect (AB) exists in cylindrical wires as the magnetoresistance (MR) oscillations with a period ΔB that is proportional to Φ0 / S, where Φ0 = h / e is the flux quantum and S is the wire cross section. The AB-type longitudinal MR oscillations with period ΔB = Φ0 / S caused by electrons undergoing continuous grazing incidence at the wire wall have been observed previously at 4.2 K in single bismuth nanowires with a diameter 0. 2 Spivak theory.

  12. Note: Computer controlled rotation mount for large diameter optics

    CERN Document Server

    Rakonjac, Ana; Deb, Amita B; Kjærgaard, Niels

    2012-01-01

    We describe the construction of a motorized optical rotation mount with a 40 mm clear aperture. The device is used to remotely control the power of large diameter laser beams for a magneto-optical trap (MOT). A piezo-electric ultrasonic motor on a printed circuit board (PCB) provides rotation with a precision better than 0.03 deg and allows for a very compact design. The rotation unit is controlled from a computer via serial communication, making integration into most software control platforms straightforward.

  13. STUDY ON RECIPROCATING SEALS FOR A LARGER DIAMETER AXIAL PISTON

    Institute of Scientific and Technical Information of China (English)

    Yang Jian; Yang Huayong; Xu Bing

    2004-01-01

    Sealing performance of the reciprocating seals on a larger diameter (100 mm in diameter ) axial piston is theoretically investigated.Based on the characteristics of the clearance flow between the seal and the piston, reasonable boundary conditions for Navier-Stokes equations are determined and the equations are modified, so that the final equations can describe the real flow state of the clearance flow.Through combining the final equations with finite element method, the pressure distributions within the clearance field during the reciprocating motion of the piston and the leakage rate with the pressure are studied.The deflections of the seal which affect sealing performance are calculated as well.Sealing performance of piston seals using oil as the working liquid is compared with using water.It is concluded that the seal using water as the working liquid is under dry friction, which cannot be dealt with the theory of fluid mechanics.The seal structure is only acceptable using oil as the working liquid..

  14. Measuring angular diameter distances of strong gravitational lenses

    CERN Document Server

    Jee, Inh; Suyu, Sherry H

    2014-01-01

    The distance-redshift relation plays a fundamental role in constraining cosmological models. In this paper, we show that measurements of positions and time delays of strongly lensed images of a background galaxy, as well as those of the velocity dispersion and mass profile of a lens galaxy, can be combined to extract the angular diameter distance of the lens galaxy. Physically, as the velocity dispersion and the time delay give a gravitational potential ($GM/r$) and a mass ($GM$) of the lens, respectively, dividing them gives a physical size ($r$) of the lens. Comparing the physical size with the image positions of a lensed galaxy gives the angular diameter distance to the lens. A mismatch between the exact locations at which these measurements are made can be corrected by measuring a local slope of the mass profile. We expand on the original idea put forward by Paraficz and Hjorth, who analyzed singular isothermal lenses, by allowing for an arbitrary slope of a power-law spherical mass density profile, an ex...

  15. The Use of Narrow Diameter Implants in the Molar Area

    Directory of Open Access Journals (Sweden)

    M. Saad

    2016-01-01

    Full Text Available Implant rehabilitations in the posterior jaw are influenced by many factors such as the condition of the remaining teeth, the force factors related to the patient, the quality of the bone, the maintenance of the hygiene, the limited bone height, the type and extent of edentulism, and the nature of the opposing arch. The gold standard is to place a regular diameter implant (>3.7 mm or a wide one to replace every missing molar. Unfortunately, due to horizontal bone resorption, this option is not possible without lateral bone augmentation. In this situation, narrow diameter implant (NDI < 3.5 mm could be the alternative to lateral bone augmentation procedures. This paper presents a clinical study where NDIs were used for the replacement of missing molars. They were followed up to 11 years. Special considerations were observed and many parameters were evaluated. NDI could be used to replace missing molar in case of moderate horizontal bone resorption if strict guidelines are respected. Yet, future controlled prospective clinical trials are required to admit their use as scientific evidence.

  16. Tunable engineered skin mechanics via coaxial electrospun fiber core diameter.

    Science.gov (United States)

    Blackstone, Britani Nicole; Drexler, Jason William; Powell, Heather Megan

    2014-10-01

    Autologous engineered skin (ES) offers promise as a treatment for massive full thickness burns. Unfortunately, ES is orders of magnitude weaker than normal human skin causing it to be difficult to apply surgically and subject to damage by mechanical shear in the early phases of engraftment. In addition, no manufacturing strategy has been developed to tune ES biomechanics to approximate the native biomechanics at different anatomic locations. To enhance and tune ES biomechanics, a coaxial (CoA) electrospun scaffold platform was developed from polycaprolactone (PCL, core) and gelatin (shell). The ability of the coaxial fiber core diameter to control both scaffold and tissue mechanics was investigated along with the ability of the gelatin shell to facilitate cell adhesion and skin development compared to pure gelatin, pure PCL, and a gelatin-PCL blended fiber scaffold. CoA ES exhibited increased cellular adhesion and metabolism versus PCL alone or gelatin-PCL blend and promoted the development of well stratified skin with a dense dermal layer and a differentiated epidermal layer. Biomechanics of the scaffold and ES scaled linearly with core diameter suggesting that this scaffold platform could be utilized to tailor ES mechanics for their intended grafting site and reduce graft damage in vitro and in vivo.

  17. Diameter of titanium nanotubes influences anti-bacterial efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Ercan, Batur; Taylor, Erik; Webster, Thomas J [School of Engineering, Brown University, Providence, RI 02917 (United States); Alpaslan, Ece, E-mail: thomas_webster@brown.edu [Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul (Turkey)

    2011-07-22

    Bacterial infection of in-dwelling medical devices is a growing problem that cannot be treated by traditional antibiotics due to the increasing prevalence of antimicrobial resistance and biofilm formation. Here, due to changes in surface parameters, it is proposed that bacterial adhesion can be prevented through nanosurface modifications of the medical device alone. Toward this goal, titanium was created to possess nanotubular surface topographies of highly controlled diameters of 20, 40, 60, or 80 nm, sometimes followed by heat treatment to control chemistry and crystallinity, through a novel anodization process. For the first time it was found that through the control of Ti surface parameters including chemistry, crystallinity, nanotube size, and hydrophilicity, significantly changed responses of both Staphylococcus epidermidis and Staphylococcus aureus (pathogens relevant for orthopaedic and other medical device related infections) were measured. Specifically, heat treatment of 80 nm diameter titanium tubes produced the most robust antimicrobial effect of all surface treatment parameters tested. This study provides the first step toward understanding the surface properties of nano-structured titanium that improve tissue growth (as has been previously observed with nanotubular titanium), while simultaneously reducing infection without the use of pharmaceutical drugs.

  18. Algorithms for the extraction of various diameter vessels.

    Science.gov (United States)

    Tremblais, B; Capelle-Laize, A S; Augereau, B

    2007-01-01

    In this communication we propose a new and automatic strategy for the multi-scale extraction of vessels. The objective is to obtain a good representation of the vessels. That is to say a precise characterization of their centerlines and diameters. The adopted solution requires the generation of an image scale-space in which the various levels of details allow to process arteries of any diameter. The proposed method is implemented using the Partial Differential Equations (PDE) and differential geometry formalisms. The differential geometry allows, by the computation of a new valley response, to characterize the centerlines of vessels as well as the bottom lines of the valleys of the image surface. The information given by the centerlines and valley response at different scales are used to obtain the 2D multi-scale centerlines of the arteries. To that purpose, we construct a multi-scale adjacency graph which permits to keep the K strongest detections. Then, the detection we obtain is coded as an attributed graph. The suggested algorithm is applied in the scope of two kinds of angiograms: coronaries and retinal angiograms.

  19. Stellar Diameters and Temperatures II. Main Sequence K & M Stars

    CERN Document Server

    Boyajian, Tabetha S; van Belle, Gerard; McAlister, Harold A; Brummelaar, Theo A ten; Kane, Stephen R; Muirhead, Phil; Jones, Jeremy; White, Russel; Schaefer, Gail; Ciardi, David; Henry, Todd; López-Morales, Mercedes; Ridgway, Stephen; Gies, Douglas; Jao, Wei-Chun; Rojas-Ayala, Bárbara; Parks, J Robert; Sturmann, Laszlo; Sturmann, Judit; Turner, Nils H; Farrington, Chris; Goldfinger, P J; Berger, David H

    2012-01-01

    We present interferometric diameter measurements of 21 K- and M- dwarfs made with the CHARA Array. This sample is enhanced by literature radii measurements to form a data set of 33 K-M dwarfs with diameters measured to better than 5%. For all 33 stars, we compute absolute luminosities, linear radii, and effective temperatures (Teff). We develop empirical relations for \\simK0 to M4 main- sequence stars between the stellar Teff, radius, and luminosity to broad-band color indices and metallicity. These relations are valid for metallicities between [Fe/H] = -0.5 and +0.1 dex, and are accurate to \\sim2%, \\sim5%, and \\sim4% for Teff, radius, and luminosity, respectively. Our results show that it is necessary to use metallicity dependent transformations to convert colors into stellar Teff's, radii, and luminosities. We find no sensitivity to metallicity on relations between global stellar properties, e.g., TEFF-radius and TEFF-luminosity. Robust examinations of single star TEFF's and radii compared to evolutionary m...

  20. COMPLICATIONS RELATED TO GASTRIC BYPASS PERFORMED WITH DIFFERENT GASTROJEJUNAL DIAMETERS

    Science.gov (United States)

    SAMPAIO-NETO, José; BRANCO-FILHO, Alcides José; NASSIF, Luis Sérgio; BROSKA, Anne Caroline; KAMEI, Douglas Jun; NASSIF, André Thá

    2016-01-01

    ABSTRACT Background: Among the options for surgical treatment of obesity, the most widely used has been the Roux-en-Y gastric bypass. The gastrojejunal anastomosis can be accomplished in two ways: handsewn or using circular and linear stapled. The complications can be divided in early and late. Aim: To compare the incidence of early complications related with the handsewn gastrojejunal anastomosis in gastric bypass using Fouchet catheter with different diameters. Method: The records of 732 consecutive patients who had undergone the bypass were retrospectively analyzed and divided in two groups, group 1 with 12 mm anastomosis (n=374), and group 2 with 15 mm (n=358). Results: The groups showed anastomotic stenosis with rates of 11% and 3.1% respectively, with p=0.05. Other variables related to the anastomosis were also analyzed, but without statistical significance (p>0.05). Conclusion: The diameter of the anastomosis of 15 mm was related with lower incidence of stenosis. It was found that these patients had major bleeding postoperatively and lower surgical site infection, and in none was observed presence of anastomotic leak. PMID:27683767

  1. Pade interpolation by F-polynomials and transfinite diameter

    CERN Document Server

    Coman, Dan

    2011-01-01

    We define $F$-polynomials as linear combinations of dilations by some frequencies of an entire function $F$. In this paper we use Pade interpolation of holomorphic functions in the unit disk by $F$-polynomials to obtain explicitly approximating $F$-polynomials with sharp estimates on their coefficients. We show that when frequencies lie in a compact set $K\\subset\\mathbb C$ then optimal choices for the frequencies of interpolating polynomials are similar to Fekete points. Moreover, the minimal norms of the interpolating operators form a sequence whose rate of growth is determined by the transfinite diameter of $K$. In case of the Laplace transforms of measures on $K$, we show that the coefficients of interpolating polynomials stay bounded provided that the frequencies are Fekete points. Finally, we give a sufficient condition for measures on the unit circle which ensures that the sums of the absolute values of the coefficients of interpolating polynomials stay bounded.

  2. Lasering in a Waveguide with Scatterers in Diameter 20 nm

    Institute of Scientific and Technical Information of China (English)

    LIU Chun-Xu; LIU Jun-Ye; ZHANG Jia-Hua; DOU Kai

    2004-01-01

    We report random lasing achieved in a MEH-PPV/glass waveguide with the TiO2 scatterers in diameter 20nm that is significantly smaller than submicrometre of TiO2 scatterers in the films or suspensions previously reported on random lasing. The spectral lines are dramatically narrowed by almost two orders of magnitude compared with those excited by a xenon lamp. The amplified spontaneous emission is identified as the dominant mechanism in our system. Light localization might be achieved in a broad class of random materials based on the features of the mean free path l* = 5.4 × 105 nm, kl* > 1 and the Thouless number 6.73 × 10-5 with k being the wave number.

  3. Molecular transport through large-diameter DNA nanopores

    Science.gov (United States)

    Krishnan, Swati; Ziegler, Daniela; Arnaut, Vera; Martin, Thomas G.; Kapsner, Korbinian; Henneberg, Katharina; Bausch, Andreas R.; Dietz, Hendrik; Simmel, Friedrich C.

    2016-01-01

    DNA-based nanopores are synthetic biomolecular membrane pores, whose geometry and chemical functionality can be tuned using the tools of DNA nanotechnology, making them promising molecular devices for applications in single-molecule biosensing and synthetic biology. Here we introduce a large DNA membrane channel with an ≈4 nm diameter pore, which has stable electrical properties and spontaneously inserts into flat lipid bilayer membranes. Membrane incorporation is facilitated by a large number of hydrophobic functionalizations or, alternatively, streptavidin linkages between biotinylated channels and lipids. The channel displays an Ohmic conductance of ≈3 nS, consistent with its size, and allows electrically driven translocation of single-stranded and double-stranded DNA analytes. Using confocal microscopy and a dye influx assay, we demonstrate the spontaneous formation of membrane pores in giant unilamellar vesicles. Pores can be created both in an outside-in and an inside-out configuration. PMID:27658960

  4. Seismic fragility test of a 6-inch diameter pipe system

    Energy Technology Data Exchange (ETDEWEB)

    Chen, W. P.; Onesto, A. T.; DeVita, V.

    1987-02-01

    This report contains the test results and assessments of seismic fragility tests performed on a 6-inch diameter piping system. The test was funded by the US Nuclear Regulatory Commission (NRC) and conducted by ETEC. The objective of the test was to investigate the ability of a representative nuclear piping system to withstand high level dynamic seismic and other loadings. Levels of loadings achieved during seismic testing were 20 to 30 times larger than normal elastic design evaluations to ASME Level D limits would permit. Based on failure data obtained during seismic and other dynamic testing, it was concluded that nuclear piping systems are inherently able to withstand much larger dynamic seismic loadings than permitted by current design practice criteria or predicted by the probabilistic risk assessment (PRA) methods and several proposed nonlinear methods of failure analysis.

  5. Solar furnace satellite for large diameter crystal growth in space

    Science.gov (United States)

    Overfelt, Tony; Wells, Mark; Blake, John

    1993-02-01

    Investigators worldwide are preparing experiments to test the influence of low gravity found in space on the growth of many crystalline materials. However, power limitations prevent existing space crystal growth furnaces from being able to process samples any larger than about 2 cm, and in addition, the background microgravity levels found on the Space Shuttle are not low enough to significantly benefit samples much larger than 2 cm. This paper describes a novel concept of a free-flying platform utilizing well-established solar furnace technology to enable materials processing in space experiments on large-diameter crystals. The conceptual design of this Solar Furnace Satellite is described along with its operational scenario and the anticipated g levels.

  6. Molecular transport through large-diameter DNA nanopores

    Science.gov (United States)

    Krishnan, Swati; Ziegler, Daniela; Arnaut, Vera; Martin, Thomas G.; Kapsner, Korbinian; Henneberg, Katharina; Bausch, Andreas R.; Dietz, Hendrik; Simmel, Friedrich C.

    2016-09-01

    DNA-based nanopores are synthetic biomolecular membrane pores, whose geometry and chemical functionality can be tuned using the tools of DNA nanotechnology, making them promising molecular devices for applications in single-molecule biosensing and synthetic biology. Here we introduce a large DNA membrane channel with an ~4 nm diameter pore, which has stable electrical properties and spontaneously inserts into flat lipid bilayer membranes. Membrane incorporation is facilitated by a large number of hydrophobic functionalizations or, alternatively, streptavidin linkages between biotinylated channels and lipids. The channel displays an Ohmic conductance of ~3 nS, consistent with its size, and allows electrically driven translocation of single-stranded and double-stranded DNA analytes. Using confocal microscopy and a dye influx assay, we demonstrate the spontaneous formation of membrane pores in giant unilamellar vesicles. Pores can be created both in an outside-in and an inside-out configuration.

  7. Experiments with large diameter gravity driven impacting liquid jets

    Science.gov (United States)

    Storr, G. J.; Behnia, M.

    The phenomenon of a liquid jet released under gravity and falling through or impacting onto another liquid before colliding with an obstructing solid surface has been studied experimentally under isothermal conditions. Usually the jet diameter was sufficiently large to ensure jet coherency until collision. Direct flow visualization was used to study jets released into water pools with no air head space and jets impacting onto water pools after falling through an air head space. It is shown that distances predicting the onset of buoyancy and the entrainment of air using derivations from continuous plunging jets, are not applicable for impacting jets. The morphology of jet debris after collision with the solid surfaces correlates with the wetting properties of the jet liquid on the surface.

  8. NEOWISE diameters and albedos: now available on PDS!

    Science.gov (United States)

    Masiero, Joseph R.; Mainzer, Amy K.; Bauer, James M.; Cutri, Roc M.; Grav, Tommy; Kramer, Emily A.; Nugent, Carolyn; Sonnett, Sarah M.; Stevenson, Rachel; Wright, Edward L.

    2016-10-01

    We present the recent PDS release of minor planet physical property data from the WISE/NEOWISE fully cryogenic, 3-band cryo, and post-cryo surveys as well as the first year of the NEOWISE-Reactivation survey. This release includes 165,865 diameters, visible albedos, near-infrared albedos, and/or beaming parameters for 140,493 unique minor planets. The published data include near-Earth asteroids, Main Belt asteroids, Hildas, Jupiter Trojans, Centaurs, active Main Belt objects and irregular satellites of Jupiter and Saturn. We provide an overview of the available data and discuss the key features of the PDS data set. The data are available online at: http://sbn.psi.edu/pds/resource/neowisediam.html.

  9. Microbes make average 2 nanometer diameter crystalline UO2 particles.

    Science.gov (United States)

    Suzuki, Y.; Kelly, S. D.; Kemner, K. M.; Banfield, J. F.

    2001-12-01

    It is well known that phylogenetically diverse groups of microorganisms are capable of catalyzing the reduction of highly soluble U(VI) to highly insoluble U(IV), which rapidly precipitates as uraninite (UO2). Because biological uraninite is highly insoluble, microbial uranyl reduction is being intensively studied as the basis for a cost-effective in-situ bioremediation strategy. Previous studies have described UO2 biomineralization products as amorphous or poorly crystalline. The objective of this study is to characterize the nanocrystalline uraninite in detail in order to determine the particle size, crystallinity, and size-related structural characteristics, and to examine the implications of these for reoxidation and transport. In this study, we obtained U-contaminated sediment and water from an inactive U mine and incubated them anaerobically with nutrients to stimulate reductive precipitation of UO2 by indigenous anaerobic bacteria, mainly Gram-positive spore-forming Desulfosporosinus and Clostridium spp. as revealed by RNA-based phylogenetic analysis. Desulfosporosinus sp. was isolated from the sediment and UO2 was precipitated by this isolate from a simple solution that contains only U and electron donors. We characterized UO2 formed in both of the experiments by high resolution-TEM (HRTEM) and X-ray absorption fine structure analysis (XAFS). The results from HRTEM showed that both the pure and the mixed cultures of microorganisms precipitated around 1.5 - 3 nm crystalline UO2 particles. Some particles as small as around 1 nm could be imaged. Rare particles around 10 nm in diameter were also present. Particles adhere to cells and form colloidal aggregates with low fractal dimension. In some cases, coarsening by oriented attachment on \\{111\\} is evident. Our preliminary results from XAFS for the incubated U-contaminated sample also indicated an average diameter of UO2 of 2 nm. In nanoparticles, the U-U distance obtained by XAFS was 0.373 nm, 0.012 nm

  10. Modular Small Diameter Vascular Grafts with Bioactive Functionalities.

    Directory of Open Access Journals (Sweden)

    Meik Neufurth

    Full Text Available We report the fabrication of a novel type of artificial small diameter blood vessels, termed biomimetic tissue-engineered blood vessels (bTEBV, with a modular composition. They are composed of a hydrogel scaffold consisting of two negatively charged natural polymers, alginate and a modified chitosan, N,O-carboxymethyl chitosan (N,O-CMC. Into this biologically inert scaffold two biofunctionally active biopolymers are embedded, inorganic polyphosphate (polyP and silica, as well as gelatin which exposes the cell recognition signal, Arg-Gly-Asp (RGD. These materials can be hardened by exposure to Ca(2+ through formation of Ca(2+ bridges between the polyanions, alginate, N,O-CMC, and polyP (alginate-Ca(2+-N,O-CMC-polyP. The bTEBV are formed by pressing the hydrogel through an extruder into a hardening solution, containing Ca(2+. In this universal scaffold of the bTEBV biomaterial, polycations such as poly(L-Lys, poly(D-Lys or a His/Gly-tagged RGD peptide (three RGD units were incorporated, which promote the adhesion of endothelial cells to the vessel surface. The mechanical properties of the biopolymer material (alginate-Ca(2+-N,O-CMC-polyP-silica revealed a hardness (elastic modulus of 475 kPa even after a short incubation period in CaCl2 solution. The material of the artificial vascular grafts (bTEBVs with an outer size 6 mm and 1.8 mm, and an inner diameter 4 mm and 0.8 mm, respectively turned out to be durable in 4-week pulsatile flow experiments at an alternating pressure between 25 and 100 mbar (18.7 and 75.0 mm Hg. The burst pressure of the larger (smaller vessels was 850 mbar (145 mbar. Incorporation of polycationic poly(L-Lys, poly(D-Lys, and especially the His/Gly-tagged RGD peptide, markedly increased the adhesion of human, umbilical vein/vascular endothelial cells, EA.HY926 cells, to the surface of the hydrogel. No significant effect of the polyP samples on the clotting of human plasma is measured. We propose that the metabolically

  11. Sustainable yields from large diameter wells in shallow weathered aquifers

    Science.gov (United States)

    Rushton, K. R.; de Silva, C. S.

    2016-08-01

    Large diameter wells in shallow weathered aquifers provide a valuable source of water for domestic and agricultural purposes in many locations including the Indian subcontinent. However, when used for irrigation, these wells often fail towards the end of the dry season. By considering two case studies in the dry and intermediate rainfall zones of Sri Lanka, reasons for the limited yield of these wells are identified. The first case study is concerned with a sloping catchment; a significant proportion of the precipitation during the rainy season either becomes runoff or passes down-gradient through the aquifer and is discharged at the ground surface. Furthermore, during the dry season, groundwater discharge continues. In the second case study the topography is generally flat but, even though the aquifer fills most years during the rainy season, there is often only sufficient water to irrigate about half of each farmer's holding. These investigations are based on field information and the development of conceptual and computational models. Of critical importance in assessing the long term yield of a well is the formation of a seepage face on the side of the well, with the water table a significant distance above the pumping water level. Consequently the water table may only be lowered to about half the depth of the well. The paper concludes with recommendations for the exploitation of groundwater from shallow weathered aquifers to minimise the risk of failure during the dry season.

  12. A 24mm diameter fibre positioner for spectroscopic surveys

    Science.gov (United States)

    Hörler, Philipp; Kronig, Luzius; Kneib, Jean-Paul; Bleuler, Hannes; Bouri, Mohamed

    2016-07-01

    One of the big research topics in modern cosmology is the mystery of dark Energy. To unveil the secret, cosmologists want to measure precisely the evolution of large scale structures in the universe. One way of doing so is to measure the 3D location of a high number of galaxies. By measuring the redshift of a galaxy, it is possible to find its distance. In order to measure a high number of galaxies in a practical amount of time, we need to observe multiple objects in parallel. Instead of a spectrograph, thousands of optical fibres are placed in the focal plane of a telescope. They will transmit the light of many objects to a spectrograph. Each fibre has to be positioned to several μm precision in the focal plane of a telescope for each exposure. Each fibre is positioned by a 2-axis fibre positioner. In this paper such a fibre positioner with 24-mm diameter is presented. It is driven by two brushless DC motors in combination with a backlash free gearbox. The positioner has an optimal central fibre path and improved angular alignment. The fibre runs through the centre of the positioner and is only bent at the top to reach its target position. In this way, the flexion and torsion of the fibre are minimal. In addition to the high positioning accuracy, the design is optimized to allow a minimal tilt error of the fibre. This is demonstrated using a novel optical tilt measurement system.

  13. Correlation Development for Sauter Mean Diameter of Rotary Atomizer

    Directory of Open Access Journals (Sweden)

    Murali.K

    2016-08-01

    Full Text Available Atomizers are of many types, among that simplex and duplex types of atomizers are used and recognized often as fuel injectors in aircrafts. Types of atomizers and features are read. Among many types of atomizer, rotary type of atomizer is selected due to its naked evident like easy retrofit to existing spreading system , able to handle large quantities, feed is possible, better economy, high peripheral speed and spread of droplets, uniform liquid feed rate, uniform distribution of feed, higher level of atomization etc., The rotary atomizer specifications and its features are listed, the droplets of rotary atomizer are visualized and readings are taken from experimental methods, such as Laser visualization method .After the droplets data alignment, the (SMD Sauter Mean Diameter is to be taken in and considered, SMD means it is a average particle (droplet size of a given particles, and it is further explained with its given relation. By SMD’s given equated form it is used to compare data between rotary atomizer particles and given particle size. By SMD it is simplified further and used to create a co-relation between SMD and rotary atomizer. The rotary atomizer data values are taken through out with the SMD to find and form a co-related derived pattern for ROTARY ATOMIZE

  14. More bounds on the diameters of convex polytopes

    CERN Document Server

    Bremner, David; Hua, William; Schewe, Lars

    2009-01-01

    Finding a good bound on the maximal edge diameter $\\Delta(d,n)$ of a polytope in terms of its dimension $d$ and the number of its facets $n$ is one of the basic open questions in polytope theory \\cite{BG}. Although some bounds are known, the behaviour of the function $\\Delta(d,n)$ is largely unknown. The Hirsch conjecture, formulated in 1957 and reported in \\cite{GD}, states that $\\Delta(d,n)$ is linear in $n$ and $d$: $\\Delta(d,n) \\leq n-d$. The conjecture is known to hold in small dimensions, i.e., for $d \\leq 3$ \\cite{VK}, along with other specific pairs of $d$ and $n$ (Table \\ref{before}). However, the asymptotic behaviour of $\\Delta(d,n)$ is not well understood: the best upper bound -- due to Kalai and Kleitman -- is quasi-polynomial \\cite{GKDK}. In this article we will show that $\\Delta(4,12)=7$ and present strong evidence for $\\Delta(5,12)=\\Delta(6,13)=7$. The first of these new values is of particular interest since it indicates that the Hirsch bound is not sharp in dimension 4.

  15. Small-Diameter PTFE Portosystemic Shunts: Portocaval vs Mesocaval

    Directory of Open Access Journals (Sweden)

    Robert Shields

    1998-01-01

    Full Text Available Fifty-seven patients with failed sclerotherapy received a mesocaval interposition shunt with an externally supported, ringed polytetrafluoroethylene prosthesis of either 10 or 12 mm diameter. Thirty-one patients had Child-Pugh gradeA disease and 26 grade B; all had a liver volume of 1000– 2500 ml. Follow-up ranged from 16 months to 6 years 3 months. Three patients (5 per cent died in the postoperative period. There were two postoperative recurrences of variceal haemorrhage and one recurrent bleed in the second year after surgery. The cumulative shunt patency rate was 95 per cent and the incidence of encephalopathy 9 per cent; the latter was successfully managed by protein restriction and/or lactulose therapy. The actuarial survival rate for the whole group at 6 years was 78 per cent, for those with Child-Pugh grade A 88 per cent and for grade B 67 per cent. Small-lumen mesocaval interposition shunting achieves portal decompression, preserves hepatopetal flow, has a low incidence of shunt thrombosis, prevents recurrent variceal bleeding and is not associated with significant postoperative encephalopathy.

  16. Multi-diameter silicon nanowires: Fabrication, characterization, and modeling

    Science.gov (United States)

    Alagoz, Arif Sinan

    Nanotechnology is a rapidly expanding interdisciplinary field offering novel devices for broad range of applications. Quantum effects and surface to volume ratio of nanostructures are strongly size dependent, and redefine material properties at nanoscale. Silicon is one of the most promising materials for next generation nanostructured transistors, photonics devices, Li-ion batteries, photovoltaic solar cells, and thermoelectric energy generators. Since electrical, optical, and mechanical properties of nanostructures strongly depend on their shape, size, periodicity, and crystal structure; it is crucial to control these parameters in order to optimize device performance for targeted applications. This dissertation is intended to develop a low-cost, low-temperature, high-throughput, and large-area nanowire fabrication method that can produce well-ordered arrays of hierarchical single-crystal silicon nanowires at large scale by using nanosphere lithography and metal-assisted chemical etching. Nanowire morphology was characterized by using scanning electron microscope and optical properties of nanowire arrays were modeled with the help of finite-difference-time domain method. These novel multi-diameter silicon nanowire arrays have the potential applications in many fields including but not limited to next generation nanowire solar cells to field ionization gas sensors.

  17. A computational algorithm addressing how vessel length might depend on vessel diameter.

    Science.gov (United States)

    Cai, Jing; Zhang, Shuoxin; Tyree, Melvin T

    2010-07-01

    The objective of this method paper was to examine a computational algorithm that may reveal how vessel length might depend on vessel diameter within any given stem or species. The computational method requires the assumption that vessels remain approximately constant in diameter over their entire length. When this method is applied to three species or hybrids in the genus Populus, vessel length is sometimes a linear function of vessel diameter and sometimes an exponential function of vessel diameter within a stem, based on R(2) values. Our results give within-species variation of vessel length versus diameter, and we compare this to between-species variation of mean diameter versus mean length.

  18. Diameter Control and Photoluminescence of ZnO Nanorods from Trialkylamines

    Directory of Open Access Journals (Sweden)

    Tamar Andelman

    2007-01-01

    Full Text Available A novel solution method to control the diameter of ZnO nanorods is reported. Small diameter (2-3 nm nanorods were synthesized from trihexylamine, and large diameter (50–80 nm nanorods were synthesized by increasing the alkyl chain length to tridodecylamine. The defect (green emission of the photoluminescence (PL spectra of the nanorods varies with diameter, and can thus be controlled by the diameter control. The small ZnO nanorods have strong green emission, while the large diameter nanorods exhibit a remarkably suppressed green band. We show that this observation supports surface oxygen vacancies as the defect that gives rise to the green emission.

  19. Comparison of CT-Determined Pulmonary Artery Diameter, Aortic Diameter, and Their Ratio in Healthy and Diverse Clinical Conditions.

    Directory of Open Access Journals (Sweden)

    Sang Hoon Lee

    Full Text Available The main pulmonary artery diameter (mPA, aortic diameter (Ao, and the mPA/Ao ratio, easily measured using chest computed tomography (CT, provide information that enables the diagnosis and evaluation of cardiopulmonary diseases. Here, we used CT to determine the sex- and age-specific distribution of normal reference values for mPA, Ao, and mPA/Ao ratio in an adult Korean population.Data from non-contrast, ECG-gated, coronary-calcium-scoring CT images of 2,547 individuals who visited the Health Screening Center of the Severance Hospital were analyzed. Healthy individuals (n = 813 included those who do not have hypertension, diabetes, asthma, obstructive lung disease, ischemic heart disease, stroke, smoking, obesity, and abnormal CT findings. Both mPA and Ao were measured at the level of bifurcation of the main pulmonary artery.The mean mPA and Ao were 25.9 mm and 30.0 mm in healthy participants, respectively, while the mean mPA/Ao ratio was 0.87. Medical conditions associated with a larger mPA were male, obesity, smoking history, hypertension, and diabetes. A larger mPA/Ao ratio was associated with female, the obese, non-smoker, normotensive, and normal serum level of lipids, while a smaller mPA/Ao ratio was associated with older age. In healthy individuals, the 90th percentile sex-specific mPA, Ao, and mPA/Ao ratio were, 31.3 mm (95% CI 29.9-32.2, 36.8 mm (95% CI 35.7-37.5, and 1.05 (95% CI 0.99-1.07 in males, and 29.6 mm (95% CI 29.1-30.2, 34.5 mm (95% CI 34.1-34.9, and 1.03 (95% CI 1.02-1.06 in females, respectively.In the Korean population, the mean mPA reference values in male and female were 26.5 mm and 25.8 mm, respectively, while the mean mPA/Ao ratio was 0.87. These values were influenced by a variety of underlying medical conditions.

  20. Assessing Pain Using the Variation Coefficient of Pupillary Diameter.

    Science.gov (United States)

    Charier, David J; Zantour, Daniel; Pichot, Vincent; Chouchou, Florian; Barthelemy, Jean-Claude M; Roche, Frederic; Molliex, Serge B

    2017-07-13

    Pupillary diameter (PD) varies under the influence of the sympathetic as well as parasympathetic systems, increasing proportionally with pain intensity. Such variations however, should not be confused with pupillary fluctuations, which refer to the fast and permanent PD fluctuations induced by the ongoing interplay between the sympathetic and parasympathetic systems, which we propose to measure using the variation coefficient of PD (VCPD). This study aimed first at correlating PD, PD increase during a contraction, and VCPD, with pain rated using a numeric rating scale (NRS) during obstetrical labor, and then at comparing such correlations with each other. Forty patients were included in the study, and 160 simultaneous ratings (NRS, PD, and VCPD) were taken: 40 in the presence of uterine contractions and 40 in the absence of such contractions, before and 20 minutes after epidural analgesia. VCPD correlates more strongly (r = .77) than PD increase (r = .42) with pain rated using a NRS. The ability of VCPD to predict the occurrence of NRS scores ≥4 during obstetrical labor is .97 (confidence interval, .93-1.0). When measured over 10 seconds during contraction, VCPD correlates more strongly than PD increase with pain rated using the NRS. Such stronger correlation allows for an easy assessment of antinociception-nociception balance. The VCPD allows for an objective assessment of pain in laboring women. It could allow for an easy assessment of pain in noncommunicating patients: newborns or very old patients, patients with serious psychological conditions, assessment during the immediate postoperative period, or in intensive care units. Copyright © 2017 American Pain Society. Published by Elsevier Inc. All rights reserved.

  1. Solar Diameter Measurements from Eclipses as a Solar Variability Proxy

    Science.gov (United States)

    Waring Dunham, David; Sofia, Sabatino; Guhl, Konrad; Herald, David Russell

    2015-08-01

    Since thermal relaxation times for the Sun are thousands of years, small variations of the Solar intensity are proportional to small variations of the Solar diameter on decadal time scales. In a combination between observations and theory, reliable values of the relation constant W are known, that allow transformation of historical variations of radius into variations of the solar luminosity. During the past 45 years, members of the International Occultation Timing Association (IOTA) have observed 20 annular and total solar eclipses from locations near the path edges. Baily’s beads, whose occurrence and duration are considerably prolonged as seen from path edge locations, were first timed visually, mostly using projection techniques, but since about 1980, they have been timed mainly from analysis of video recordings. The edge locations have the advantage that most of the beads are defined by the same features in the lunar polar regions that cause the phenomena at each eclipse. Some of the best-observed modern eclipses can be used to assess the accuracy of the results, which are limited mainly by the intensity drop at the Sun’s edge, and the consequent uncertainty in defining the edge. In addition, direct visual contact timings made near the path edges during earlier eclipses, back to 1715, have been found in the literature, and analyzed. Although the observations seem to show small variations, they are only a little larger than the assessed accuracies. The results can be improved with a consistent re-analysis of the observations using the much more accurate lunar profile data that is now available from the Japanese Kaguya and NASA’s LRO lunar orbiter observations. Also, IOTA has plans to observe future eclipses with a variety of techniques that were used in the past, to better assess the accuracies of the different observational methods that have been used, and determine any systematic differences between them.

  2. AUTOMATED WATER LEVEL MEASUREMENTS IN SMALL-DIAMETER AQUIFER TUBES

    Energy Technology Data Exchange (ETDEWEB)

    PETERSEN SW; EDRINGTON RS; MAHOOD RO; VANMIDDLESWORTH PE

    2011-01-14

    Groundwater contaminated with hexavalent chromium, strontium-90, and uranium discharges into the Columbia River along approximately 16 km (10 mi) of the shoreline. Various treatment systems have and will continue to be implemented to eliminate the impact of Hanford Site contamination to the river. To optimize the various remediation strategies, it is important to understand interactions between groundwater and the surface water of the Columbia River. An automated system to record water levels in aquifer sampling tubes installed in the hyporheic zone was designed and tested to (1) gain a more complete understanding of groundwater/river water interactions based on gaining and losing conditions ofthe Columbia River, (2) record and interpret data for consistent and defensible groundwater/surface water conceptual models that may be used to better predict subsurface contaminant fate and transport, and (3) evaluate the hydrodynamic influence of extraction wells in an expanded pump-and-treat system to optimize the treatment system. A system to measure water levels in small-diameter aquifer tubes was designed and tested in the laboratory and field. The system was configured to allow manual measurements to periodically calibrate the instrument and to permit aquifer tube sampling without removing the transducer tube. Manual measurements were collected with an e-tape designed and fabricated especially for this test. Results indicate that the transducer system accurately records groundwater levels in aquifer tubes. These data are being used to refine the conceptual and numeric models to better understand interactions in the hyporheic zone of the Columbia River and the adjacent river water and groundwater, and changes in hydrochemistry relative to groundwater flux as river water recharges the aquifer and then drains back out in response to changes in the river level.

  3. Integrated spectral study of small angular diameter galactic open clusters

    Science.gov (United States)

    Clariá, J. J.; Ahumada, A. V.; Bica, E.; Pavani, D. B.; Parisi, M. C.

    2017-10-01

    This paper presents flux-calibrated integrated spectra obtained at Complejo Astronómico El Leoncito (CASLEO, Argentina) for a sample of 9 Galactic open clusters of small angular diameter. The spectra cover the optical range (3800-6800 Å), with a resolution of ∼14 Å. With one exception (Ruprecht 158), the selected clusters are projected into the fourth Galactic quadrant (282o < l < 345o) near the Galactic plane (∣b∣ ≤ 9o). We performed simultaneous estimates of foreground interstellar reddening and age by comparing the continuum distribution and line strenghts of the cluster spectra with those of template cluster spectra with known parameters. We thus provide spectroscopic information independent from that derived through color-magnitude diagram studies. We found three clusters (Collinder 249, NGC 4463 and Ruprecht 122) younger than ∼40 Myr, four moderately young ones (BH 92, Harvard 5, Hogg 14 and Pismis 23) with ages within 200-400 Myr, and two intermediate-age ones (Ruprecht 158 and ESO 065-SC07) with ages within 1.0-2.2 Gyr. The derived foreground E(B - V) color excesses vary from around 0.0 in Ruprecht 158 to ∼1.1 in Pismis 23. In general terms, the results obtained show good agreement with previous photometric results. In Ruprecht 158 and BH 92, however, some differences are found between the parameters here obtained and previous values in the literature. Individual spectra of some comparatively bright stars located in the fields of 5 out of the 9 clusters here studied, allowed us to evaluate their membership status. The current cluster sample complements that of 46 open clusters previously studied by our group in an effort to gather a spectral library with several clusters per age bin. The cluster spectral library that we have been building is an important tool to tie studies of resolved and unresolved stellar content.

  4. Height-diameter relationships of tropical Atlantic moist forest trees in southeastern Brazil

    OpenAIRE

    Marcos Augusto da Silva Scaranello; Luciana Ferreira Alves; Simone Aparecida Vieira; Plinio Barbosa Camargo; Carlos Alfredo Joly; Luiz Antônio Martinelli

    2013-01-01

    Site-specific height-diameter models may be used to improve biomass estimates for forest inventories where only diameter at breast height (DBH) measurements are available. In this study, we fit height-diameter models for vegetation types of a tropical Atlantic forest using field measurements of height across plots along an altitudinal gradient. To fit height-diameter models, we sampled trees by DBH class and measured tree height within 13 one-hectare permanent plots established at four altitu...

  5. Bloch-Wave Engineered Submicron Diameter Micropillars with Quality Factors Exceeding 10,000

    DEFF Research Database (Denmark)

    Hofling, S.; Lermer, M.; Gregersen, Niels;

    2011-01-01

    Adiabatic design submicron diameter quantum-dot micropillars have been designed and implemented for cavity quantum electrodynamics experiments. Ultra-high experimental quality factors (>10,000) are obtained for submicron diameters and strong light-matter interaction is observed.......Adiabatic design submicron diameter quantum-dot micropillars have been designed and implemented for cavity quantum electrodynamics experiments. Ultra-high experimental quality factors (>10,000) are obtained for submicron diameters and strong light-matter interaction is observed....

  6. Experimental study on stability of sunken large diameter cylindrical structure on sandy seabed during construction period

    Institute of Scientific and Technical Information of China (English)

    秦崇仁; 庞红犁; 李世森; 张伟

    2002-01-01

    A systematic experimental research work is done for the stability of sunken large diameter cylinder during construction period. It is the first research that gives the method for assessing the stability of the larger diameter cylindrical structure, a set of values is derived also for the critical stability indices of the large diameter cylinder sunken to the sandy seabed.

  7. Comprehensive database of diameter-based biomass regressions for North American tree species

    Science.gov (United States)

    Jennifer C. Jenkins; David C. Chojnacky; Linda S. Heath; Richard A. Birdsey

    2004-01-01

    A database consisting of 2,640 equations compiled from the literature for predicting the biomass of trees and tree components from diameter measurements of species found in North America. Bibliographic information, geographic locations, diameter limits, diameter and biomass units, equation forms, statistical errors, and coefficients are provided for each equation,...

  8. Basic maneuvers for an inspection robot for small diameter gas distribution mains

    NARCIS (Netherlands)

    Dertien, Edwin Christian; Stramigioli, Stefano

    2011-01-01

    This video shows the design of a mechanical structure of a miniature pipe inspection robot (MPR) capable of moving trough very small pipes (up to 41 mm inner diameter) as well as a wide range of diameters (63 to 125 mm outer diameter). The requirement to negotiate bends, T-joints and steep

  9. Basic maneuvers for an inspection robot for small diameter gas distribution mains

    NARCIS (Netherlands)

    Dertien, Edwin; Stramigioli, Stefano

    2011-01-01

    This video shows the design of a mechanical structure of a miniature pipe inspection robot (MPR) capable of moving trough very small pipes (up to 41 mm inner diameter) as well as a wide range of diameters (63 to 125 mm outer diameter). The requirement to negotiate bends, T-joints and steep inclinati

  10. 78 FR 60897 - Certain Welded Large Diameter Line Pipe From Japan

    Science.gov (United States)

    2013-10-02

    ... COMMISSION Certain Welded Large Diameter Line Pipe From Japan Determination On the basis of the record \\1... the antidumping duty order on certain welded large diameter line pipe from Japan would likely to lead... Certain Welded Large Diameter Line Pipe from Japan: Investigation No. 731-TA-919 (Second Review). By order...

  11. Height-diameter allometry of tropical forest trees

    Directory of Open Access Journals (Sweden)

    T. R. Feldpausch

    2011-05-01

    Full Text Available Tropical tree height-diameter (H:D relationships may vary by forest type and region making large-scale estimates of above-ground biomass subject to bias if they ignore these differences in stem allometry. We have therefore developed a new global tropical forest database consisting of 39 955 concurrent H and D measurements encompassing 283 sites in 22 tropical countries. Utilising this database, our objectives were:

    1. to determine if H:D relationships differ by geographic region and forest type (wet to dry forests, including zones of tension where forest and savanna overlap.

    2. to ascertain if the H:D relationship is modulated by climate and/or forest structural characteristics (e.g. stand-level basal area, A.

    3. to develop H:D allometric equations and evaluate biases to reduce error in future local-to-global estimates of tropical forest biomass.

    Annual precipitation coefficient of variation (PV, dry season length (SD, and mean annual air temperature (TA emerged as key drivers of variation in H:D relationships at the pantropical and region scales. Vegetation structure also played a role with trees in forests of a high A being, on average, taller at any given D. After the effects of environment and forest structure are taken into account, two main regional groups can be identified. Forests in Asia, Africa and the Guyana Shield all have, on average, similar H:D relationships, but with trees in the forests of much of the Amazon Basin and tropical Australia typically being shorter at any given D than their counterparts elsewhere. The region-environment-structure model with the lowest Akaike's information criterion and lowest deviation estimated stand-level H across all plots to within amedian −2.7 to 0.9% of the true value. Some of the plot-to-plot variability in

  12. Height-diameter allometry of tropical forest trees

    Directory of Open Access Journals (Sweden)

    T. R. Feldpausch

    2010-10-01

    Full Text Available Tropical tree height-diameter (H:D relationships may vary by forest type and region making large-scale estimates of above-ground biomass subject to bias if they ignore these differences in stem allometry. We have therefore developed a new global tropical forest database consisting of 39 955 concurrent H and D measurements encompassing 283 sites in 22 tropical countries. Utilising this database, our objectives were:

      1. to determine if H:D relationships differ by geographic region and forest type (wet to dry forests, including zones of tension where forest and savanna overlap.

      2. to ascertain if the H:D relationship is modulated by climate and/or forest structural characteristics (e.g. stand-level basal area, A.

      3. to develop H:D allometric equations and evaluate biases to reduce error in future local-to-global estimates of tropical forest biomass.

    Annual precipitation coefficient of variation (PV, dry season length (SD, and mean annual air temperature (TA emerged as key drivers of variation in H:D relationships at the pantropical and region scales. Vegetation structure also played a role with trees in forests of a high A being, on average, taller at any given D. After the effects of environment and forest structure are taken into account, two main regional groups can be identified. Forests in Asia, Africa and the Guyana Shield all have, on average, similar H:D relationships, but with trees in the forests of much of the Amazon Basin and tropical Australia typically being shorter at any given D than their counterparts elsewhere.

    The region-environment-structure model with the lowest Akaike's information criterion and lowest deviation estimated stand-level H across all plots to within a median –2.7 to 0.9% of the true value. Some of the plot

  13. Selective control of small versus large diameter axons using infrared laser light (Conference Presentation)

    Science.gov (United States)

    Lothet, Emilie H.; Shaw, Kendrick M.; Horn, Charles C.; Lu, Hui; Wang, Yves T.; Jansen, E. Duco; Chiel, Hillel J.; Jenkins, Michael W.

    2016-03-01

    Sensory information is conveyed to the central nervous system via small diameter unmyelinated fibers. In general, smaller diameter axons have slower conduction velocities. Selective control of such fibers could create new clinical treatments for chronic pain, nausea in response to chemo-therapeutic agents, or hypertension. Electrical stimulation can control axonal activity, but induced axonal current is proportional to cross-sectional area, so that large diameter fibers are affected first. Physiologically, however, synaptic inputs generally affect small diameter fibers before large diameter fibers (the size principle). A more physiological modality that first affected small diameter fibers could have fewer side effects (e.g., not recruiting motor axons). A novel mathematical analysis of the cable equation demonstrates that the minimum length along the axon for inducing block scales with the square root of axon diameter. This implies that the minimum length along an axon for inhibition will scale as the square root of axon diameter, so that lower radiant exposures of infrared light will selectively affect small diameter, slower conducting fibers before those of large diameter. This prediction was tested in identified neurons from the marine mollusk Aplysia californica. Radiant exposure to block a neuron with a slower conduction velocity (B43) was consistently lower than that needed to block a faster conduction velocity neuron (B3). Furthermore, in the vagus nerve of the musk shrew, lower radiant exposure blocked slow conducting fibers before blocking faster conducting fibers. Infrared light can selectively control smaller diameter fibers, suggesting many novel clinical treatments.

  14. Pseudomagnitudes and differential surface brightness: Application to the apparent diameter of stars

    Science.gov (United States)

    Chelli, Alain; Duvert, Gilles; Bourgès, Laurent; Mella, Guillaume; Lafrasse, Sylvain; Bonneau, Daniel; Chesneau, Olivier

    2016-05-01

    The diameter of a star is a major observable that serves to test the validity of stellar structure theories. It is also a difficult observable that is mostly obtained with indirect methods since the stars are so remote. Today only ~600 apparent star diameters have been measured by direct methods: optical interferometry and lunar occultations. Accurate star diameters are now required in the new field of exoplanet studies, since they condition the planets' sizes in transit observations, and recent publications illustrate a visible renewal of interest in this topic. Our analysis is based on the modeling of the relationship between measured angular diameters and photometries. It makes use of two new reddening-free concepts: a distance indicator called pseudomagnitude, and a quasi-experimental observable that is independent of distance and specific to each star, called the differential surface brightness (DSB). The use of all the published measurements of apparent diameters that have been collected so far, and a careful modeling of the DSB allow us to estimate star diameters with a median statistical error of 1.1%, knowing their spectral type and, in the present case, the VJHKs photometries. We introduce two catalogs, the JMMC Measured Diameters Catalog (JMDC), containing measured star diameters, and the second version of the JMMC Stellar Diameter Catalog (JSDC), augmented to about 453 000 star diameters. Finally, we provide simple formulas and a table of coefficients to quickly estimate stellar angular diameters and associated errors from (V, Ks) magnitudes and spectral types.

  15. Diameter Tuning of Single Walled Carbon Nanotubes with Reaction Temperature Using a Co Monometallic Catalyst

    Energy Technology Data Exchange (ETDEWEB)

    Li, N.; Wang, X; Ren, F; Haller, G; Pfefferle, L

    2009-01-01

    Metal incorporated MCM-41 has proven to be a valuable template for the growth of narrow distributions of single-walled carbon nanotubes (SWNT), producing samples with a wide range of different mean diameters. The ability to obtain narrow diameter distributions at different mean diameters is important for applications that require particular (n,m) nanotubes. Another advantage of this system is the ease of cleaning and low metal content as compared to bimetallic systems. In this Article, we show that Co-MCM-41 allows diameter tuning of SWNT produced over a broad diameter range (from 0.6-0.8 to 1.8-2.0 nm) by changing reaction temperature. The lower temperature reaction provides a robust means to obtain very small diameter SWNT. X-ray absorption experiments show that the change in SWNT diameter correlates with the change in metal particle size.

  16. Search for decays of superdense nuclei in a two-meter propane chamber

    Energy Technology Data Exchange (ETDEWEB)

    Abdivaliev, A. (Leninabadskij Gosudarstvennyj Pedagogicheskij Inst. (USSR)); Zubarev, A.N.; Korzhev, N.A.; Kochurov, A.G.; Nikitin, A.V.; Pechenov, V.N.; Smirnov, N.A.; Sokolov, V.P.; Solov' ev, M.I.; Troyan, Yu.A. (Joint Inst. for Nuclear Research, Dubna (USSR))

    1981-10-01

    The upper limits of the cross sections for formation of superdense nuclei are determined. They lie between 5x10/sup -33/ and 10/sup -28/ cm/sup 2/ for /sub 28/Ni/sup 58/, /sub 82/Pb/sup 208/, /sub 29/Cu/sup 63/, /sub 73/Ta/sup 181/ and /sub 6/C/sup 12/ targets irradiated by 1.90, 3.36 or 9.86 GeV/c protons, 0.95 GeV/c per nucleon ..cap alpha..-particles and 3.36 GeV/c per nucleon carbon nuclei. Decay particles with energies exceeding 16.4 MeV were searched for.

  17. Numerical simulation of low-Reynolds number flows past two tandem cylinders of different diameters

    Directory of Open Access Journals (Sweden)

    Yong-tao WANG

    2013-10-01

    Full Text Available The flow past two tandem circular cylinders of different diameters was simulated using the ?nite volume method. The diameter of the downstream main cylinder (D was kept constant, and the diameter of the upstream control cylinder (d varied from 0.1D to D. The studied Reynolds numbers based on the diameter of the downstream main cylinder were 100 and 150. The gap between the control cylinder and the main cylinder (G ranged from 0.1D to 4D. It is concluded that the gap-to-diameter ratio (G/D and the diameter ratio between the two cylinders (d/D have important effects on the drag and lift coef?cients, pressure distributions around the cylinders, vortex shedding frequencies from the two cylinders, and ?ow characteristics.

  18. The Probability Density Functions to Diameter Distributions for Scots Pine Oriental Beech and Mixed Stands

    Directory of Open Access Journals (Sweden)

    Aydın Kahriman

    2011-11-01

    Full Text Available Determine the diameter distribution of a stand and its relations with stand ages, site index, density and mixture percentage is very important both biologically and economically. The Weibull with two parameters, Weibull with three parameters, Gamma with two parameters, Gamma with three parameters, Beta, Lognormal with two parameters, Lognormal with three parameters, Normal, Johnson SB probability density functions were used to determination of diameter distributions. This study aimed to compared based on performance of describing different diameter distribution and to describe the best successful function of diameter distributions. The data were obtaited from 162 temporary sample plots measured Scots pine and Oriental beech mixed stands in Black Sea Region. The results show that four parameter Johnson SB function for both scots pine and oriental beech is the best successful function to describe diameter distributions based on error index values calculated by difference between observed and predicted diameter distributions.

  19. Relationship between diameter of split Hopkinson pressure bar and minimum loading rate under rock failure

    Institute of Scientific and Technical Information of China (English)

    LI Xi-bing; HONG Liang; YIN Tu-bing; ZHOU Zi-long; YE Zhou-yuan

    2008-01-01

    In order to investigate the relationship between bar diameter and loading rate of the split Hopkinson pressure bar(SHPB) setup under the failure of rock specimen and realize the medium strain rate loading of specimen, new SHPB setups with different elastic bar's diameters of 22, 36, 50 and 75 mm were constructed. The tests were carried out on these setups at different loading rates, and the specimens had the same diameter of elastic bars and same ratio of length to diameter. The test results show that the larger the elastic bar's diameter is, the less the loading rate is needed to cause specimen failure, they show good power relationship, and that under the same strain rate loading, specimens are broken more seriously with larger diameter SHPB setup than with smaller one.

  20. Automatic calculation of tree diameter from stereoscopic image pairs using digital image processing.

    Science.gov (United States)

    Yi, Faliu; Moon, Inkyu

    2012-06-20

    Automatic operations play an important role in societies by saving time and improving efficiency. In this paper, we apply the digital image processing method to the field of lumbering to automatically calculate tree diameters in order to reduce culler work and enable a third party to verify tree diameters. To calculate the cross-sectional diameter of a tree, the image was first segmented by the marker-controlled watershed transform algorithm based on the hue saturation intensity (HSI) color model. Then, the tree diameter was obtained by measuring the area of every isolated region in the segmented image. Finally, the true diameter was calculated by multiplying the diameter computed in the image and the scale, which was derived from the baseline and disparity of correspondence points from stereoscopic image pairs captured by rectified configuration cameras.

  1. A continuously variable beam-diameter, high-fluence, Q-switched Nd:YAG laser for tattoo removal: comparison of the maximum beam diameter to a standard 4-mm-diameter treatment beam.

    Science.gov (United States)

    Bernstein, Eric F; Civiok, Jennifer M

    2013-12-01

    Laser beam diameter affects the depth of laser penetration. Q-switched lasers tend to have smaller maximum spot sizes than other dermatologic lasers, making beam diameter a potentially more significant factor in treatment outcomes. To compare the clinical effect of using the maximum-size treatment beam available for each delivered fluence during laser tattoo removal to a standard 4-mm-diameter treatment beam. Thirteen tattoos were treated in 12 subjects using a Q-switched Nd:YAG laser equipped with a treatment beam diameter that was adjustable in 1 mm increments and a setting that would enable the maximally achievable diameter ("MAX-ON" setting) with any fluence. Tattoos were randomly bisected and treated on one side with the MAX-ON setting and on the contralateral side with a standard 4-mm-diameter spot ("MAX-OFF" setting). Photographs were taken 8 weeks following each treatment and each half-tattoo was evaluated for clearance on a 10-point scale by physicians blinded to the treatment conditions. Tattoo clearance was greater on the side treated with the MAX-ON setting in a statistically significant manner following the 1st through 4th treatments, with the MAX-OFF treatment site approaching the clearance of the MAX-ON treatment site after the 5th and 6th treatments. This high-energy, Q-switched Nd:YAG laser with a continuously variable spot-size safely and effectively removes tattoos, with greater removal when using a larger spot-size. © 2013 Wiley Periodicals, Inc.

  2. Design of Dual Axis Laser Scanning Diameter Measuring Gauge System with PID Co

    Institute of Scientific and Technical Information of China (English)

    LI Xin-qiu; LI Zhi-wei; LIU Da-jiang

    2009-01-01

    Dual axis laser scanning diameter measuring gauge system(DALSDMGS)with PID controller,which can be used for online non-contact diameter measuring and control on the hose,wire and rod production line,is introduced.The measure principle and implementation of this system are also presented.A PID control module with PID parameters tuning is included in the measuring and control system,which functions as a PID automatic controller of the diameter.

  3. Angular Diameter of the Asteroids Vesta and Pallas Determined from Speckle Observations

    Science.gov (United States)

    1978-05-24

    Arizona 85721 19. IKY WORDS (Continue en reverse eid* 1 necessry’ and Identify by block number)I... Speckle interferometry Asteroids Vesta Pallas 20...applied to Vesta and Pallas, yielding diameters of 550±23 and 873*55 kin, respectivell The improved Vesta speckle diameter is in excellent agreement with...other measurements for Vesta . However, the derived Pallas diameter is slightly larger than other measurements. This is perhaps attributable to

  4. Inter-observer variation in ultrasound measurement of the volume and diameter of thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Jun; Baek, Jung Hwan; Hong, Min Ji; Lee, Jeong Hyun [Dept. of Radiology, and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    Thyroid nodule measurement using ultrasonography (US) is widely performed in various clinical scenarios. The purpose of this study was to evaluate inter-observer variation in US measurement of the volume and maximum diameter of thyroid nodules. This retrospective study included 73 consecutive patients with 85 well-defined thyroid nodules greater than 1 cm in their maximum diameter. US examinations were independently performed by using standardized measurement methods, conducted by two clinically experienced thyroid radiologists. The maximum nodule diameter and nodule volume, calculated from nodule diameters using the ellipsoid formula, were obtained by each reader. Inter-observer variations in volume and maximum diameter were determined using 95% Bland-Altman limits of agreement. The degree of inter-observer variations in volumes and the maximum diameters were compared using the Student's t test, between nodules < 2 cm in maximum diameter and those with > or = 2 cm. The mean inter-observer difference in measuring the nodule volume was -1.6%, in terms of percentage of the nodule volume, and the 95% limit of agreement was +/- 13.1%. For maximum nodule diameter, the mean inter-observer difference was -0.6%, in terms of percentage of the nodule diameter, and the 95% limit of agreement was +/- 7.3%. Inter-observer variation in volume was greater in nodules of < 2 cm in maximum diameter, compared to the larger nodules (p = 0.035). However, no statistically significant difference was noted between the two groups regarding maximum nodule diameters (p = 0.511). Any differences smaller than 13.1% and 7.3% in volume and maximum diameter, respectively, measured by using US for well-defined thyroid nodules of > 1 cm should not be considered as a real change in size.

  5. Use of a coherent fiber bundle for multi-diameter single fiber reflectance spectroscopy

    OpenAIRE

    Hoy, C.L.; Gamm, U. A.; Sterenborg, H. J. C. M.; Robinson, D. J.; Amelink, A.

    2012-01-01

    Multi-diameter single fiber reflectance (MDSFR) spectroscopy enables quantitative measurement of tissue optical properties, including the reduced scattering coefficient and the phase function parameter γ. However, the accuracy and speed of the procedure are currently limited by the need for co-localized measurements using multiple fiber optic probes with different fiber diameters. This study demonstrates the use of a coherent fiber bundle acting as a single fiber with a variable diameter for ...

  6. Risk of dislocation using large- vs. small-diameter femoral heads in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Plate Johannes F

    2012-10-01

    Full Text Available Abstract Background Dislocation remains a difficult problem in total hip arthroplasty. Large-diameter femoral heads may lower the incidence of dislocation by enhancing the jump distance and decreasing impingement, but their performance against small-diameter heads has not been assessed. This study compared the mid-term radiographic and functional outcomes of two matched cohorts of patients undergoing total hip arthroplasty who had a high pre-operative risk for dislocation and who received either small-diameter (26- or 28-millimeters or large-diameter (≥36-millimeters femoral heads. Methods All patients who received large-diameter heads (≥36-millimeter between 2002 and 2005, and who had pre-operative risk factors for dislocation, were identified in the institution’s joint registry. Forty-one patients (52 hips who received large-diameter heads were identified, and these patients were matched to 48 patients (52 hips in the registry who received small-diameter femoral heads. Results At mean final follow-up of 62 months (range, 49 to 101 months, both groups achieved excellent functional outcomes as measured by Harris Hip scores, with slightly better final scores in the large-diameter group (90 vs. 83 points. No patient showed any radiographic signs of loosening. No patient dislocated in the large-diameter femoral head group; the smaller-diameter group had a greater rate of dislocation (3.8%, 2 out of 52. Conclusions Large-diameter femoral head articulations may reduce dislocation rates in patients who have a high pre-operative risk for dislocation while providing the same functional improvements and safety as small-diameter bearings.

  7. Reliability Analysis of Bearing Capacity of Large-Diameter Piles under Osterberg Test

    Directory of Open Access Journals (Sweden)

    Lei Nie

    2013-05-01

    Full Text Available This study gives the reliability analysis of bearing capacity of large-diameter piles under osterberg test. The limit state equation of dimensionless random variables is utilized in the reliability analysis of vertical bearing capacity of large-diameter piles based on Osterberg loading tests. And the reliability index and the resistance partial coefficient under the current specifications are calculated using calibration method. The results show: the reliable index of large-diameter piles is correlated with the load effect ratio and is smaller than the ordinary piles; resistance partial coefficient of 1.53 is proper in design of large-diameter piles.

  8. Relationship between retinal vessel diameters and retinopathy in the Inter99 Eye Study

    DEFF Research Database (Denmark)

    Drobnjak, Dragana; Munch, Inger Christine; Glümer, Charlotte

    2017-01-01

    .001), and decreased with higher HDL cholesterol (p  diabetes, but not in participants without diabetes......© 2017 The Authors Purpose To examine the association between retinal vessel diameters and retinopathy in participants with and without type 2 diabetes in a Danish population-based cohort. Methods The study included 878 persons aged 30 to 60 years from the Inter99 Eye Study. Retinopathy was defined...... as a presence of one or more retinal hemorrhages or one or more microaneurysms. Vessel diameters were expressed as central retinal artery equivalent diameter (CRAE) and central retinal vein equivalent diameter (CRVE). Multiple linear regression analyses were performed. Results Among participants with diabetes...

  9. Quantification of pulmonary vessel diameter in low-dose CT images

    Science.gov (United States)

    Rudyanto, Rina D.; Ortiz de Solórzano, Carlos; Muñoz-Barrutia, Arrate

    2015-03-01

    Accurate quantification of vessel diameter in low-dose Computer Tomography (CT) images is important to study pulmonary diseases, in particular for the diagnosis of vascular diseases and the characterization of morphological vascular remodeling in Chronic Obstructive Pulmonary Disease (COPD). In this study, we objectively compare several vessel diameter estimation methods using a physical phantom. Five solid tubes of differing diameters (from 0.898 to 3.980 mm) were embedded in foam, simulating vessels in the lungs. To measure the diameters, we first extracted the vessels using either of two approaches: vessel enhancement using multi-scale Hessian matrix computation, or explicitly segmenting them using intensity threshold. We implemented six methods to quantify the diameter: three estimating diameter as a function of scale used to calculate the Hessian matrix; two calculating equivalent diameter from the crosssection area obtained by thresholding the intensity and vesselness response, respectively; and finally, estimating the diameter of the object using the Full Width Half Maximum (FWHM). We find that the accuracy of frequently used methods estimating vessel diameter from the multi-scale vesselness filter depends on the range and the number of scales used. Moreover, these methods still yield a significant error margin on the challenging estimation of the smallest diameter (on the order or below the size of the CT point spread function). Obviously, the performance of the thresholding-based methods depends on the value of the threshold. Finally, we observe that a simple adaptive thresholding approach can achieve a robust and accurate estimation of the smallest vessels diameter.

  10. TRANSFINITE DIAMETER AND ANALYTIC CONTINUATION OF FUNCTIONS OF TWO COMPLEX VARIABLES

    Science.gov (United States)

    of domains in the complex z-plane whose boundary has a given transfinite diameter. Some asymptotic results whichALLOW THE C LCULATION OF THE TR NSFI I...DI R OF A PLAN R DOMAIN BY MEANS OF THE KERNEL FUNCTION OF THIS DOMAIN IS OBTAINED. The definitions of a transfinite diameter of produc s s

  11. Diameters of normal and pathological aortic bifurcations and the development of

    NARCIS (Netherlands)

    Rinsum, Aart Cornelis van

    1984-01-01

    This thesis examines the geometry of the distal abdominal aorta and aortic bifurcation. The small (< 10 mm) internal diameter of the distal abdominal aorta in a number of young women in whom an aortic bifurcation prosthesis was inserted was the indication for this study. Data concerning diameters of

  12. Influence of tube and particle diameter on heat transport in packed beds

    NARCIS (Netherlands)

    Borkink, J.G.H.; Borkink, J.G.H.; Westerterp, K.R.

    1992-01-01

    Influence of the tube and particle diameter and shape, as well as their ratio, on the radial heat transport in packed beds has been studied. Heat transport experiments were performed with four different packings in three wall-cooled tubes, which differed in inner diameter only. Experimental values f

  13. Automated Nanofiber Diameter Measurement in SEM Images Using a Robust Image Analysis Method

    Directory of Open Access Journals (Sweden)

    Ertan Öznergiz

    2014-01-01

    Full Text Available Due to the high surface area, porosity, and rigidity, applications of nanofibers and nanosurfaces have developed in recent years. Nanofibers and nanosurfaces are typically produced by electrospinning method. In the production process, determination of average fiber diameter is crucial for quality assessment. Average fiber diameter is determined by manually measuring the diameters of randomly selected fibers on scanning electron microscopy (SEM images. However, as the number of the images increases, manual fiber diameter determination becomes a tedious and time consuming task as well as being sensitive to human errors. Therefore, an automated fiber diameter measurement system is desired. In the literature, this task is achieved by using image analysis algorithms. Typically, these methods first isolate each fiber in the image and measure the diameter of each isolated fiber. Fiber isolation is an error-prone process. In this study, automated calculation of nanofiber diameter is achieved without fiber isolation using image processing and analysis algorithms. Performance of the proposed method was tested on real data. The effectiveness of the proposed method is shown by comparing automatically and manually measured nanofiber diameter values.

  14. Influence of tube and particle diameter on heat transport in packed beds

    NARCIS (Netherlands)

    Borkink, J.G.H.; Borkink, J.G.H.; Westerterp, K.R.

    1992-01-01

    Influence of the tube and particle diameter and shape, as well as their ratio, on the radial heat transport in packed beds has been studied. Heat transport experiments were performed with four different packings in three wall-cooled tubes, which differed in inner diameter only. Experimental values

  15. The impact of exercise training on the diameter dilator response to forearm ischaemia in healthy men

    NARCIS (Netherlands)

    Thijssen, D.H.J.; Tinken, T.M.; Hopkins, N.; Dawson, E.A.; Cable, N.T.; Green, D.J.

    2011-01-01

    AIM: Recent studies found differences between groups in the rate of diameter increase following the flow-mediated dilation (FMD). Whilst exercise training alters the magnitude of the FMD, little is known about the impact of exercise training on the rate of diameter increase. The aim of this study is

  16. Maximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    Wever, JJ; Blankensteijn, JD; Mali, WPTM; Eikelboom, BC

    2000-01-01

    Background: follow-up after endovascular abdominal aortic aneurysm repair (EAR) generally consists of serial diameter measurements. A size change after EAR, however, is the consequence of alterations of the excluded aneurysm sac volume. Objective: to assess the agreement between diameter measurement

  17. A computational algorithm addressing how vessel length might depend on vessel diameter

    Science.gov (United States)

    Jing Cai; Shuoxin Zhang; Melvin T. Tyree

    2010-01-01

    The objective of this method paper was to examine a computational algorithm that may reveal how vessel length might depend on vessel diameter within any given stem or species. The computational method requires the assumption that vessels remain approximately constant in diameter over their entire length. When this method is applied to three species or hybrids in the...

  18. 78 FR 14964 - Small Diameter Graphite Electrodes From the People's Republic of China: Preliminary Results of...

    Science.gov (United States)

    2013-03-08

    ... International Trade Administration Small Diameter Graphite Electrodes From the People's Republic of China... graphite electrodes (graphite electrodes) from the People's Republic of China (PRC), covering the period... graphite electrodes with a nominal or actual diameter of 400 millimeters (16 inches) or less and graphite...

  19. 78 FR 56864 - Small Diameter Graphite Electrodes From the People's Republic of China: Affirmative Final...

    Science.gov (United States)

    2013-09-16

    ... International Trade Administration Small Diameter Graphite Electrodes From the People's Republic of China... from the People's Republic of China (PRC) of graphite electrodes, produced and/or exported by Sinosteel...\\ \\1\\ See Antidumping Duty Order: Small Diameter Graphite Electrodes From the People's Republic of...

  20. Sample preparation and scanning protocol for computerised analysis of root length and diameter

    NARCIS (Netherlands)

    Bouma, T.J.; Nielsen, K.F.; Koutstaal, B.P.

    2000-01-01

    Root length and diameter distribution are important characteristics to be considered when describing and comparing root systems. Root length and root-diameter distribution may be obtained in two ways: by microscopical measurements, which are laborious, or by computerised analysis, which is fast but

  1. Influence of cataract surgery and blood pressure changes caused by sodium restriction on retinal vascular diameter

    Directory of Open Access Journals (Sweden)

    Takatoshi Tano

    2010-11-01

    Full Text Available Takatoshi Tano1, Yoshimune Hiratsuka2, Koichi Ono1, Akira Murakami11Department of Ophthalmology, Juntendo University School of Medicine, Tokyo; 2National Institute of Public Health, Tokyo, JapanPurpose: To investigate the impact of cataract surgery and blood pressure changes induced by one week of sodium restriction on retinal vascular diameter.Methods: Fundus photographs of 200 patients were obtained before and one week after cataract surgery. For one week after admission, 100 patients received sodium restriction and 100 patients (ie, the control group did not receive sodium restriction. The diameter of the retinal vessels and blood pressure were compared between the sodium restriction group and the control group. The vascular diameter was measured using an objective computer-based method.Results: Neither group had a significant change in the diameter of the retinal vessels after cataract surgery. Although there was no significant change in retinal arterial and venular diameter in the sodium restriction group, one-week sodium restriction significantly reduced mean blood pressure. However, multiple linear regression analyses indicated that an increase in retinal arteriolar diameter was significantly associated with diabetes, hyperlipidemia, and alcohol intake.Conclusion: Cataract surgery and blood pressure reduction induced by one week of sodium restriction resulted in no significant change in retinal arteriolar diameter.Keywords: cataract surgery, hypertension, retinal blood vessel diameter, retinal fundus camera, sodium restriction.

  2. Irrigation effects on diameter growth of 2-year-old Paulownia tomentosa saplings

    Institute of Scientific and Technical Information of China (English)

    Javad Eshaghi Rad; Seyed Rostam Mousavi Mirkala

    2015-01-01

    Species of Paulownia are fast-growing trees that are planted in many countries in green spaces and agroforestry systems. We studied the influence of irrigation on the diameter growth of 2-year-old Paulownia tomentosa saplings planted in 3 m × 3 m grids at Nazlou Campus of Urmia University, Iran. Completely randomized experi-mental design was used with four irrigation amount, viz. 10, 15, 20 and 25 L, and three irrigation intervals, viz. 3-and 6-days, in 8 replications. During the growth season, we measured collar diameters of all saplings at the end of each month. Diameter growth declined with reduced irrigation amount and increased irrigation interval. The lowest average diameter growth (9 mm) was recorded for 10 L water at 6-day intervals and maximum average diameter growth (28.7 mm) was recorded for 25 L volume at 3-day intervals. The latter treatment resulted in significantly greater diameter growth than any other treatment (except 20 L at 3-day intervals). More than 80% of diameter growth was achieved in the first 3 months. Therefore, it is essential to irrigate with 25 L of water at 3-day intervals during the first three growth months to achieve maximum diameter growth for 2-year-old P. tomentosa saplings.

  3. Production and cost of harvesting, processing, and transporting small-diameter (< 5 inches) trees for energy

    Science.gov (United States)

    Fei Pan; Han-Sup Han; Leonard R. Johnson; William J. Elliot

    2008-01-01

    Dense, small-diameter stands generally require thinning from below to improve fire-tolerance. The resulting forest biomass can be used for energy production. The cost of harvesting, processing, and transporting small-diameter trees often exceeds revenues due to high costs associated with harvesting and transportation and low market values for forest biomass....

  4. Follow-up on Small Abdominal Aortic Aneurysms Using Three Dimensional Ultrasound: Volume Versus Diameter.

    Science.gov (United States)

    Ghulam, Q M; Bredahl, K K; Lönn, L; Rouet, L; Sillesen, H H; Eiberg, J P

    2017-10-01

    Rupture risk in abdominal aortic aneurysms (AAAs) is assessed using AAA diameter; yet 10% of ruptures occur in a small aneurysm. This underlines the inadequacy of diameter as a standalone parameter. In this prospective follow-up study, ultrasound determined aneurysm diameter was compared with aneurysm volume determined by three dimensional ultrasound (3D-US) in a group of 179 AAAs. This was a prospective cohort study with repeated diameter and volume measurements by 3D-US. In total, 179 patients with small infrarenal AAAs (diameter 30-55 mm) were enrolled consecutively. At enrolment and at 12 month follow-up, maximum diameter, using dual plane technique, and three dimensional volume were measured. Based on a previous accuracy study, significant change in diameter and volume were defined as an increase exceeding the known range of variability (ROV) of each US technique; ±3.7 mm and ±8.8 mL, respectively. Post-hoc Kaplan-Meier analysis was performed to estimate time to conversion to treatment after the conclusion of the follow-up period between two groups. In total, 125 patients (70%) had an unchanged diameter during follow-up. In this group, 50 patients (40%) had an increasing aortic volume. Forty-five (83%) of the 54 patients with an increasing aortic diameter showed a corresponding volume increase. During a median follow-up of 367 days (364-380 days), a mean increase in diameter of 2.7 mm (±2.6 mm) and a mean increase in volume of 11.6 mL (±9.9 mL) were recorded. In post-hoc analysis, it was found that more AAAs with a stable diameter and a growing volume than AAAs with a stable diameter and volume were undergoing aortic repair during follow-up, based on the maximum diameter. In this cohort of small AAAs, 40% of patients with a stable diameter had an increasing volume at 12 month follow-up. From this perspective, 3D-US could have a future supplemental role in AAA surveillance programmes. Copyright © 2017 European Society for Vascular Surgery. Published

  5. Diameter structure modeling and the calculation of plantation volume of black poplar clones

    Directory of Open Access Journals (Sweden)

    Andrašev Siniša

    2004-01-01

    Full Text Available A method of diameter structure modeling was applied in the calculation of plantation (stand volume of two black poplar clones in the section Aigeiros (Duby: 618 (Lux and S1-8. Diameter structure modeling by Weibull function makes it possible to calculate the plantation volume by volume line. Based on the comparison of the proposed method with the existing methods, the obtained error of plantation volume was less than 2%. Diameter structure modeling and the calculation of plantation volume by diameter structure model, by the regularity of diameter distribution, enables a better analysis of the production level and assortment structure and it can be used in the construction of yield and increment tables.

  6. MENGETAHUI PENGARUH KOEFISIEN VISKOSITAS AKUADES TERHADAP VARIASI DIAMETER TABUNG MENGGUNAKAN ADOBE AUDITION 1.5

    Directory of Open Access Journals (Sweden)

    M Barkah Salim

    2014-09-01

    Full Text Available An experiment had been carried out to determine the viscosity coefficient of aquadest (destilled water by using Stokes falling ball method. The detection of the balltime during the experiment is done using magnetic induction censor while the reading of induction time data uses adobe audition 1.5 software. By doing this technique the measurement of magnetic ball travel time can minimize the weakness of the ball falling travel measurement which is usually done manually. In this experiment the determination of the coefficient of viscosity by varying the diameter of the tube. The purpose of this experiment was to determine the effect of tube diameter on the viscosity coefficient  Based on the results of the experiment, the bigger the tube diameter is, the smaller the viscosity coefficient will be. If the tube diameter is bigger again, the viscosity coefficient will be flatter. So, viscosity coefficient is always constant for each of the increase of tube diameter.

  7. Angular diameter estimation of interferometric calibrators - Example of lambda Gruis, calibrator for VLTI-AMBER

    CERN Document Server

    Cruzalebes, P; Sacuto, S; Bonneau, D; 10.1051/0004-6361/200913686

    2010-01-01

    Context. Accurate long-baseline interferometric measurements require careful calibration with reference stars. Small calibrators with high angular diameter accuracy ensure the true visibility uncertainty to be dominated by the measurement errors. Aims. We review some indirect methods for estimating angular diameter, using various types of input data. Each diameter estimate, obtained for the test-case calibrator star lambda Gru, is compared with the value 2.71 mas found in the Bord\\'e calibrator catalogue published in 2002. Methods. Angular size estimations from spectral type, spectral index, in-band magnitude, broadband photometry, and spectrophotometry give close estimates of the angular diameter, with slightly variable uncertainties. Fits on photometry and spectrophotometry need physical atmosphere models with "plausible" stellar parameters. Angular diameter uncertainties were estimated by means of residual bootstrapping confidence intervals. All numerical results and graphical outputs presented in this pap...

  8. Pseudomagnitudes and Differential Surface Brightness: Application to the apparent diameter of stars

    CERN Document Server

    Chelli, Alain; Bourgès, Laurent; Mella, Guillaume; Lafrasse, Sylvain; Bonneau, Daniel; Chesneau, Olivier

    2016-01-01

    The diameter of a star is a major observable that serves to test the validity of stellar structure theories. It is also a difficult observable that is mostly obtained with indirect methods since the stars are so remote. Today only ~600 apparent star diameters have been measured by direct methods: optical interferometry and lunar occultations. Accurate star diameters are now required in the new field of exoplanet studies, since they condition the planets' sizes in transit observations, and recent publications illustrate a visible renewal of interest in this topic. Our analysis is based on the modeling of the relationship between measured angular diameters and photometries. It makes use of two new reddening-free concepts: a distance indicator called pseudomagnitude, and a quasi-experimental observable that is independent of distance and specific to each star, called the differential surface brightness (DSB). The use of all the published measurements of apparent diameters that have been collected so far, and a c...

  9. Embedding a carbon nanotube across the diameter of a solid state nanopore

    CERN Document Server

    Sadki, E S; Vlassarev, D; Golovchenko, J A; Branton, D

    2013-01-01

    A fabrication method for positioning and embedding a single-walled carbon nanotube (SWNT) across the diameter of a solid state nanopore is presented. Chemical vapor deposition (CVD) is used to grow SWNTs over arrays of focused ion beam (FIB) milled pores in a thin silicon nitride membrane. This typically yields at least one pore whose diameter is centrally crossed by a SWNT. The final diameter of the FIB pore is adjusted to create a nanopore of any desired diameter by atomic layer deposition (ALD), simultaneously embedding and insulating the SWNT everywhere but in the region that crosses the diameter of the final nanopore, where it remains pristine and bare. This nanotube-articulated nanopore is an important step towards the realization of a new type of detector for biomolecule sensing and electronic characterization, including DNA sequencing.

  10. Association of deep venous thrombosis with calf vein diameter in acute hemorrhagic stroke.

    Science.gov (United States)

    Ogata, Toshiyasu; Yasaka, Masahiro; Wakugawa, Yoshiyuki; Kitazono, Takanari; Okada, Yasushi

    2013-10-01

    We investigated the association between the development of deep venous thrombosis (DVT) and calf vein diameter in patients with acute hemorrhagic stroke. We measured the maximum diameter of paralytic side posttibial veins (PTVs) and peroneal veins (PVs) in 49 patients with intracerebral hemorrhage on admission and at 2 weeks after stroke onset by ultrasonography. We also examined for the presence or absence of DVT, and then analyzed the association of DVT with the maximum vein diameter. At 2 weeks after stroke, DVTs were detected in PTVs in 7 patients and in PVs in 6 patients. The maximum calf vein diameters at 2 weeks were significantly greater in patients with DVT compared with those without DVT (PTV, P = .033; PV, P = .015). Although calf vein diameter at admission did not influence the future incidence of DVT in patients with intracerebral hemorrhage, the presence of DVT was associated with calf vein dilatation.

  11. Impact of vent pipe diameter on characteristics of waste degradation in semi-aerobic bioreactor landfill.

    Science.gov (United States)

    Jiang, Guobin; Liu, Dan; Chen, Weiming; Ye, Zhicheng; Liu, Hong; Li, Qibin

    2017-08-01

    The evolution mechanism of a vent pipe diameter on a waste-stabilization process in semi-aerobic bioreactor landfills was analyzed from the organic-matter concentration, biodegradability, spectral characteristics of dissolved organic matter, correlations and principal-component analysis. Waste samples were collected at different distances from the vent pipe and from different landfill layers in semi-aerobic bioreactor landfills with different vent pipe diameters. An increase in vent pipe diameter favored waste degradation. Waste degradation in landfills can be promoted slightly when the vent pipe diameter increases from 25 to 50 mm. It could be promoted significantly when the vent pipe diameter was increased to 75 mm. The vent pipe diameter is important in waste degradation in the middle layer of landfills. The dissolved organic matter in the waste is composed mainly of long-wave humus (humin), short-wave humus (fulvic acid) and tryptophan. The humification levels of the waste that was located at the center of vent pipes with 25-, 50- and 75-mm diameters were 2.2682, 4.0520 and 7.6419 Raman units, respectively. The appropriate vent pipe diameter for semi-aerobic bioreactor landfills with an 800-mm diameter was 75 mm. The effect of different vent pipe diameters on the degree of waste stabilization is reflected by two main components. Component 1 is related mainly to the content of fulvic acid, biologically degradable material and organic matter. Component 2 is related mainly to the content of tryptophan and humin from the higher vascular plants.

  12. Influence of Age and Apical Diameter on the Success of Endodontic Regeneration Procedures.

    Science.gov (United States)

    Estefan, Bishoy Safwat; El Batouty, Kariem Mostafa; Nagy, Mohamed Mokhtar; Diogenes, Anibal

    2016-11-01

    Treatment of immature permanent teeth with necrotic pulp and apical pathosis constitutes a challenge for endodontists. The present study was done to evaluate the effect of age and apical diameter on the regenerative potential of young permanent immature teeth with necrotic pulps. Immature necrotic permanent maxillary incisors (n = 40) of patients 9-18 years old were divided into 2 groups according to the treatment protocol: group Y (younger age group), 9-13 years and group O (older age group), 14-18 years. Each group was further subdivided into 2 subgroups according to apical diameter, subgroup (n) (narrower diameter) between 0.5 and 1 mm and subgroup (w) (wider diameter) equal to or greater than 1 mm. Revascularization procedures were performed for all patients. Follow-up was done for up to 12 months. Standardized radiographs were digitally evaluated for increase in root length and thickness and decrease in apical diameter. After the follow-up period, most of the cases demonstrated radiographic evidence of periapical healing. Group Y showed significant progressive increase in root length and width and decrease in apical diameter. Subgroup (w) representing wider apical diameter showed significant progress as well. It was found that revascularization procedures can be implemented in any age ranging from 9 to 18 years; however, younger age groups were better candidates for revascularization procedure than older ones. Regarding the apical diameter, regeneration procedures were successful with apical diameters as small as 0.5 mm. However, teeth with preoperative wider diameters (≥1 mm) demonstrated greater increase in root thickness, length, and apical narrowing. Copyright © 2016 American Association of Endodontists. All rights reserved.

  13. Estimation of the diameter-charge distribution in polydisperse electrically charged sprays of electrically insulating liquids

    Science.gov (United States)

    Rigit, A. R. H.; Shrimpton, John S.

    2009-06-01

    The majority of scientific and industrial electrical spray applications make use of sprays that contain a range of drop diameters. Indirect evidence suggests the mean drop diameter and the mean drop charge level are usually correlated. In addition, within each drop diameter class there is every reason to suspect a distribution of charge levels exist for a particular drop diameter class. This paper presents an experimental method that uses the joint PDF of drop velocity and diameter, obtained from phase Doppler anemometry measurements, and directly obtained spatially resolved distributions of the mass and charge flux to obtain a drop diameter and charge frequency distribution. The method is demonstrated using several data-sets obtained from experimental measurements of steady poly-disperse sprays of an electrically insulating liquid produced with the charge injection technique. The space charge repulsion in the spray plume produces a hollow cone spray structure. In addition an approximate self-similarity is observed, with the maximum radial mass and charge flow occurring at r/ d ~ 200. The charge flux profile is slightly offset from the mass flux profile, and this gives direct evidence that the spray specific charge increases from approximately 20% of the bulk mean spray specific charge on the spray axis to approximately 200% of the bulk mean specific charge in the periphery of the spray. The results from the drop charge estimation model suggest a complex picture of the correlation between drop charge and drop diameter, with spray specific charge, injection velocity and orifice diameter all contributing to the shape of the drop diameter-charge distribution. Mean drop charge as a function of the Rayleigh limit is approximately 0.2, and is invariant with drop diameter and also across the spray cases tested.

  14. Endovascular radiofrequency ablation. Effect on the vein diameter using the ClosureFast(®) catheter.

    Science.gov (United States)

    Bauzá Moreno, Hernán; Dotta, Mariana; Katsini, Roxana; Marquez Fosser, Carolina; Rochet, Sofía; Pared, Carlos; Martinez, Hugo

    2016-01-01

    Endovascular radiofrequency with first generation catheters was not successful due to its technical difficulty and restrictions in veins with diameters larger than 12mm. However, using the new catheter there is not enough scientific evidence to affirm that the diameter represents a technical limitation. The aim of this study was to evaluate and compare pre and post-operative venous trunks diameter, aiming at the reduction of size after 6 months with last generation catheters. Retrospective observational and descriptive study on a cohort of patients with insufficiency of the great saphenous vein, small saphenous vein and anterior accessory vein operated on with last generation radiofrequency catheters. The diameters were evaluated in the pre and post-operative period with ultrasound. Between 2007 and 2014 a total of 365 ablations were performed in veins with an average diameter of 9±3.1mm showing a reduction of it after 6 months with a mean value of 5.2±0.8mm (P<.0001). Total occlusion was also observed in 100% of cases and complications such as deep vein thrombosis in 0.5% and heat-induced thrombosis in 1.1%. A significant reduction in venous diameter after endovascular treatment with the new ClosureFast(®) catheters was checked, even in veins with diameters greater than 12mm. Copyright © 2016 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. SAGITTAL DIAMETER OF FORAMEN MAGNUM IN NORMAL POPULATION: AN MRI STUDY

    Directory of Open Access Journals (Sweden)

    Lakshmi

    2015-11-01

    Full Text Available Lower position of cerebellar tonsils was frequently noticed in Western studies. In some of the studies, sagittal diameter of foramen magnum was found to be larger in cases of Chiari malformation. However, there are no Indian studies for comparison. Our study was proposed to determine the standard values for sagittal diameter of foramen magnum in various age groups and both sexes. This gives a guideline for further studies in pathological conditions like Craniovertebral Junctional (CVJ anomalies, and Chiari malformation. The sagittal diameter of foramen magnum was measured in 515 patients during MRI investigation directly on the MR images on the MR monitor in mid sagittal sections of head and cervical spine. The patients underwent the MR investigation for various vague complaints at the Radiology Department of SCTIMST, Trivandrum. They were found to have normal brain and spinal cord. They ranged from 2 months to 80 years of age in both sexes. Established cases of CVJ anomalies and raised intracranial tension were excluded. The results showed a mean sagittal diameter of 35.57 ± 3.72 mm with a range of 15 to 45 mm. The sagittal diameter increased up to 15 years, then remained static thereafter. Females showed smaller diameter compared to males. ANOVA showed a high statistically significant P-value of 0.001 for males and 0.004 for females. The study resulted in standard values of sagittal diameter of foramen magnum for different age groups in both sexes.

  16. Dimensional Analysis of Average Diameter of Bubbles for Bottom Blown Oxygen Copper Furnace

    Directory of Open Access Journals (Sweden)

    Dongxing Wang

    2016-01-01

    Full Text Available Average diameter of bubbles is important in copper furnace. Based on the principle of similarity, a slice water model of a furnace with bottom-blown oxygen in matte-smelting process was established. A high-speed camera was used to record images continuously and clearer pictures were selected for treatment. Finally, image processing software was used for obtaining the average diameter of the bubbles. The effects of different injection conditions and equipment factors such as the diameter of nozzle, the nozzle installing angle, and gas velocity on the average diameter of bubbles were studied with cold water model experiment, exploring the dispersion and disintegration rules of bubbles. According to experimental data and Buckingham’s theorem, by using dimensional analysis method, an empirical formula on average diameter of bubbles was established (dB=0.41666d0.29374θ-0.46572v-0.16725. It can be seen from the formula that nozzle installing angle and diameter of nozzle make the most impact on the average diameter of bubbles in bottom blown oxygen copper furnace.

  17. Control of diameter and morphology of poly(vinylidene fluoride) nanofibers fabricated by electrospinning

    Science.gov (United States)

    Jing, Hongjun; Du, Xiaosong; Jiang, Yadong

    2009-11-01

    This paper described a procedure based on electrospinning for generating nanofibers with controllable diameters and morphology. When an acetone and N,N-dimethylacetamide (DMAc) mixture solvent containing poly(vinylidene fluoride) (PVDF) was injected through a needle under a strong electric field, nanofibers made of PVDF formed as a result of electrostatic jetting. To control the diameter and morphology of PVDF nanofibers, the solution properties and process parameters were investigated, such as polymer concentration, the ratio of the mixture solvent, feeding rate, applied electric field, and needle-to-collector distance. The fabricated fibers were 30-8000 nm in diameter. The increase in the polymer concentration caused an increase in the fiber diameter. However, the increase in the feeding rate and applied electric field decreased the fiber diameter. Variation in the needle-to-collector distance did not result in significant changes in the fiber diameter. The ratio of the solvent also had a very significant impact on electrospinning. The diameter and morphology of the PVDF nanofibers were characterized by optical microscope and scanning electron microscope (SEM).

  18. Effects of the hydraulic coupling between xylem and phloem on diurnal phloem diameter variation.

    Science.gov (United States)

    Sevanto, Sanna; Hölttä, Teemu; Holbrook, N Michele

    2011-04-01

    Measurements of diurnal diameter variations of the xylem and phloem are a promising tool for studying plant hydraulics and xylem-phloem interactions in field conditions. However, both the theoretical framework and the experimental verification needed to interpret phloem diameter data are incomplete. In this study, we analytically evaluate the effects of changing the radial conductance between the xylem and the phloem on phloem diameter variations and test the theory using simple manipulation experiments. Our results show that phloem diameter variations are mainly caused by changes in the radial flow rate of water between the xylem and the phloem. Reducing the hydraulic conductance between these tissues decreases the amplitude of phloem diameter variation and increases the time lag between xylem and phloem diameter variation in a predictable manner. Variation in the amplitude and timing of diameter variations that cannot be explained by changes in the hydraulic conductance, could be related to changes in the osmotic concentration in the phloem. © 2011 Blackwell Publishing Ltd.

  19. Implosion dynamics and x-ray generation in small-diameter wire-array Z pinches.

    Science.gov (United States)

    Ivanov, V V; Sotnikov, V I; Kindel, J M; Hakel, P; Mancini, R C; Astanovitskiy, A L; Haboub, A; Altemara, S D; Shevelko, A P; Kazakov, E D; Sasorov, P V

    2009-05-01

    It is known from experiments that the radiated x-ray energy appears to exceed the calculated implosion kinetic energy and Spitzer resistive heating [C. Deeney, Phys. Rev. A 44, 6762 (1991)] but possible mechanisms of the enhanced x-ray production are still being discussed. Enhanced plasma heating in small-diameter wire arrays with decreased calculated kinetic energy was investigated, and a review of experiments with cylindrical arrays of 1-16 mm in diameter on the 1 MA Zebra generator is presented in this paper. The implosion and x-ray generation in cylindrical wire arrays with different diameters were compared to find a transition from a regime where thermalization of the kinetic energy is the prevailing heating mechanism to regimes with other dominant mechanisms of plasma heating. Loads of 3-8 mm in diameter generate the highest x-ray power at the Zebra generator. The x-ray power falls in 1-2 mm loads which can be linked to the lower efficiency of plasma heating with the lack of kinetic energy. The electron temperature and density of the pinches also depend on the array diameter. In small-diameter arrays, 1-3 mm in diameter, ablating plasma accumulates in the inner volume much faster than in loads of 12-16 mm in diameter. Correlated bubblelike implosions were observed with multiframe shadowgraphy. Investigation of energy balance provides evidence for mechanisms of nonkinetic plasma heating in Z pinches. Formation and evolution of bright spots in Z pinches were studied with a time-gated pinhole camera. A comparison of x-ray images with shadowgrams shows that implosion bubbles can initiate bright spots in the pinch. Features of the implosions in small-diameter wire arrays are discussed to identify mechanisms of energy dissipation.

  20. Maximum length of large diameter Czochralski silicon single crystals at fracture stress limit of seed

    Science.gov (United States)

    Kim, K. M.; Smetana, P.

    1990-03-01

    Growth of large diameter Czochralski (CZ) silicon crystals require complete elimination of dislocations by means of Dash technique, where the seed diameter is reduced to a small size typically 3 mm in conjunction with increase in the pull rate. The maximum length of the large CZ silicon is estimated at the fracture stress limit of the seed neck diameter ( d). The maximum lengths for 200 and 300 mm CZ crystals amount to 197 and 87 cm, respectively, with d = 0.3 cm; the estimated maximum weight is 144 kg.

  1. Diameter-Controllable Magnetic Properties of Co Nanowire Arrays by Pulsed Electrodeposition

    Directory of Open Access Journals (Sweden)

    Youwen Yang

    2010-01-01

    Full Text Available The Co nanowires with different diameters were prepared by pulsed electrodeposition into anodic alumina membranes oxide templates. The micrographs and crystal structures of nanowires were studied by FE-SEM, TEM, and XRD. Due to their cylindrical shape, the nanowires exhibit perpendicular anisotropy. The coercivity and loop squareness (Mr/Ms of Co nanowires depend strongly on the diameter. Both coercivity and Mr/Ms decrease with increasing wire diameter. The behavior of the nanowires is explained briefly in terms of localized magnetization reversal.

  2. Experimental study on large diameter drilling in hard rock annular coring

    Institute of Scientific and Technical Information of China (English)

    Yinzhu WU; Guochun YANG; Wenchen WANG

    2008-01-01

    Based on analyzing method of large diameter hard rock drilling at home and abroad, the authors proposed a set of drilling of large diameter hard rock annular coring in low energy consumption, low cost and high efficiency. The prototype of drilling tools was designed and was made. The experimental result of the prototype indicates that this plan and technology are feasible and reach the anticipated object of design. A set of drilling tools has been offered for the constructs of large diameter hard rock coring.

  3. The Relationships Between Diameter Stump Height (d0.30) and Diameter Breast Height (d1.30) for Scotch Pine (Pinus sylvestris (L.)) in West Black Sea RegionThe Relationships Between Diameter Stump Height (d0.30) and Diameter Breast Height (d1.30) for Scotc

    OpenAIRE

    ŞENYURT, Muammer

    2012-01-01

    In this study, it is proposed to determine the relationship between the diameter at stump height (d0.3) and diameter breast height (d1.30) for Scotch Pine (Pinus sylvestris (L.)) in West Black Sea Region including Kastamonu, Bolu and Ankara forest regional offices. For this purpose, 101 temporary sample plots were obtained and 1111 tree measurements for stump height (d0.3) and diameter breast height (d1.3) were carried out. The different regression models were selected and compared to some ...

  4. Propagation characteristics of the silica and silicon subwavelength-diameter hollow wire waveguides

    Institute of Scientific and Technical Information of China (English)

    Man Wu; Weiqing Huang; Lingling Wang

    2008-01-01

    @@ The basic propagation properties of the silica and silicon subwavelength-diameter hollow wire waveguides have been investigated by comparison. It shows that the silica and silicon subwavelength-diameter hollow wire waveguides have some interesting properties, such as enhanced evanescent field in the cladding, enhanced intensity in the hollow core, and large waveguide dispersion. For the different confinement ability, the enhanced field in the hollow core and cladding of the silica subwavelength-diameter hollow wire is much stronger than that of the silicon one for the same size.

  5. Constructions of hamiltonian graphs with bounded degree and diameter O (log n)

    CERN Document Server

    c, Aleksandar Ili\\'

    2011-01-01

    Token ring topology has been frequently used in the design of distributed loop computer networks and one measure of its performance is the diameter. We propose an algorithm for constructing hamiltonian graphs with $n$ vertices and maximum degree $\\Delta$ and diameter $O (\\log n)$, where $n$ is an arbitrary number. The number of edges is asymptotically bounded by $(2 - \\frac{1}{\\Delta - 1} - \\frac{(\\Delta - 2)^2}{(\\Delta - 1)^3}) n$. In particular, we construct a family of hamiltonian graphs with diameter at most $2 \\lfloor \\log_2 n \\rfloor$, maximum degree 3 and at most $1+11n/8$ edges.

  6. Diameter-dependent electronic transport properties of Au-catalyst/Ge-nanowire Schottky diodes

    Energy Technology Data Exchange (ETDEWEB)

    Picraux, S Thomas [Los Alamos National Laboratory; Leonard, Francois [SNL; Swartzentruber, Brian S [SNL; Talin, A Alee [SNL

    2008-01-01

    We present electronic transport measurements in individual Au-catalyst/Ge-nanowire interfaces demonstrating the presence of a Schottky barrier. Surprisingly, the small-bias conductance density increases with decreasing diameter. Theoretical calculations suggest that this effect arises because electron-hole recombination in the depletion region is the dominant charge transport mechanism, with a diameter dependence of both the depletion width and the electron-hole recombination time. The recombination time is dominated by surface contributions and depends linearly on the nanowire diameter.

  7. Evaluation of the Load-Displacement Relationships for Large-Diameter Piles in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Brodbaek, K. T.; Moller, M.;

    2009-01-01

    was developed for slender piles with diameters much less than 6 m and it is based on a limited number of tests. The aim of the present work is to extend the p-y curve method to large-diameter non-slender piles by considering the effects of the pile diameter on the soil response. The main focus is the initial...... stiffness of the p-y curves. The evaluation is based on experimental work as well as three-dimensional numerical analyses in the commercial programme FLAC3D....

  8. Experimental Research on Large Diameter Cast-in-Place Piles Embedded in Rock

    Institute of Scientific and Technical Information of China (English)

    衡朝阳; 何满潮; 姚爱军

    2001-01-01

    This paper expatiated the field test of large diameter cast-in-place piles embedded in soft rock, including static loading test, high or low strain dynamic test, measurement of stresses and strains of pile body, and pressure measurements between pile tip and soft rock. The relative in-situ test problems are discussed. Based on the limit equilibrium theory and the load transfer equation, a synthesis method of analyzing the ultimate carrying capacity of single large diameter pile is put forward. The research results show that the key to determining the ultimate carrying capacity of single pile with a large diameter is the analysis of the intensity of soft rock.

  9. Alpha particles energy estimation from track diameter development in a CR-39 detector.

    Science.gov (United States)

    Azooz, Aassim A; Al-Jubbori, Mushtaq A

    2016-09-01

    The slight nonlinearity in temporal development of tracks diameter in CR-39 nuclear track detectors is examined with the aim of attempting to find if such nonlinearity can be directly related to the charged particle energy. Narrowly spaced etching time-diameter experimental data for alpha particles at five energy values and for one additional energy value etched at five different temperatures are obtained. Initial results show good indication that measuring such time-diameter relationship can form a useful energy estimation tool. Good consistency with other independent published results is obtained.

  10. Certification of NIST SRM 1961: 30 μm Diameter Polystyrene Spheres

    Science.gov (United States)

    Hartman, Arie W.; Doiron, Theodore D.; Hembree, Gary G.

    1991-01-01

    This report describes the certification of SRM 1961, an NIST Standard Reference Material for particle diameter. It consists of an aqueous suspension of monosize 30 μm diameter polystyrene spheres. The primary technique used optical microscopy; it gave a mean diameter value D¯=29.62±0.04μm and a standard deviation of the size distribution σD = 0.21 μm. Over 2000 spheres were measured. The supporting technique used electron microscopy, which yielded D¯=29.68±0.11μm. Ninety spheres were measured.

  11. Influence of scanning force microscope loading force on measurement of ion—track diameter

    Institute of Scientific and Technical Information of China (English)

    WangYu-Gang; AckermannJ; 等

    1997-01-01

    Scanning force microscope(SFM) was operated in the lateral-force mode with different loading forces.The mica samples were irradiated by Se ions with a kinetic energy of 11.4MeV/u.The"full-height width" and the "half-height width" of track profiles were used to evaluate the ion-track diameter,For the former method,the average track diameter increases slowly with increasing loading force between SFM tip and sample.For the later method,the average diameters of ion track nearly keep a common value as the SFM loading force increases.

  12. Abdominal Aortic Diameter Is Increased in Males with a Family History of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Mejnert Jørgensen, Trine; Houlind, K; Green, A

    2014-01-01

    OBJECTIVE: To investigate, at a population level, whether a family history of abdominal aortic aneurysm (AAA) is independently related to increased aortic diameter and prevalence of AAA in men, and to elucidate whether the mean aortic diameter and the prevalence of AAA are different between...... participants with male and female relatives with AAA. DESIGN: Observational population-based cross-sectional study. MATERIALS: 18,614 male participants screened for AAA in the VIVA-trial 2008-2011 with information on both family history of AAA and maximal aortic diameter. METHODS: Standardized ultrasound scan...... diagnosed with AAA, and 38 had AAA. Participants with a family history of AAA (+FH) had a significantly larger mean maximum aortic diameter (20.50 mm) compared with participants without family history of AAA (-FH) (19.07 mm, p AAA had significantly larger mean...

  13. Large-diameter femoral heads in total hip arthroplasty: an evidence-based review.

    Science.gov (United States)

    Banerjee, Samik; Pivec, Robert; Issa, Kimona; Kapadia, Bhaveen H; Khanuja, Harpal S; Mont, Michael A

    2014-11-01

    Recent advances in the wear characteristics and material properties of highly cross-linked polyethyl-ene and fourth-generation ceramic bearings have led to increasing use of large-diameter (≥ 36 mm) femoral heads in total hip arthroplasty (THA). In this article, we review the current concepts and principles behind use of large-diameter ceramic or cobalt-chromium femoral heads on polyethylene bearings in THA. We specifically review the biomechanics, some of the early concerns about polyethylene wear and rim fractures, recent improvements in material properties of polyethylene and ceramic bearings, dislocation rates, and clinical and functional outcomes of large-diameter heads in THA. Recent literature suggests that the incidence of dislocation has been substantially reduced because of improvements in jump distance and impingement-free range of motion with use of large-diameter heads. Limited evidence suggests excellent short-term and midterm clinical and functional outcomes with these heads.

  14. The Effect of Sodium Chlorophyllin on Polyvinyl Alcohol Electrospun Nanofiber Diameters

    OpenAIRE

    Jēgina, S; Šutka, A; Kukle, S

    2016-01-01

    The studies have shown that concentrations of sodium chlorophyllin in the range from 1 wt% to 5 wt% have the ability to influence the viscosity and conductivity of the PVA solution and diameters of electrospun nanofiber composites.

  15. Enhanced Algorithms for Estimating Tree Trunk Diameter Using 2D Laser Scanner

    Directory of Open Access Journals (Sweden)

    Ola Ringdahl

    2013-10-01

    Full Text Available Accurate vehicle localization in forest environments is still an unresolved problem. Global navigation satellite systems (GNSS have well known limitations in dense forest, and have to be combined with for instance laser based SLAM algorithms to provide satisfying accuracy. Such algorithms typically require accurate detection of trees, and estimation of tree center locations in laser data. Both these operations depend on accurate estimations of tree trunk diameter. Diameter estimations are important also for several other forestry automation and remote sensing applications. This paper evaluates several existing algorithms for diameter estimation using 2D laser scanner data. Enhanced algorithms, compensating for beam width and using multiple scans, were also developed and evaluated. The best existing algorithms overestimated tree trunk diameter by ca. 40%. Our enhanced algorithms, compensating for laser beam width, reduced this error to less than 12%.

  16. СOMPACT COMPLEX FOR PROCESSING OF LARGE-DIAMETER PIPES INTO THE ROLLING STEEL PRODUCTS

    OpenAIRE

    Steblov, A. В.; A. A. Zlobin

    2016-01-01

    A mini-plant conception for processing of previously used large-diameter pipes into the small-section rolling steel products. Projects with capacity from 15 to 200 thousand tons per year are realized in the UIS.

  17. Diameter and Temperature Dependence of Thermal Conductivity of Single-Walled Carbon Nanotubes

    Institute of Scientific and Technical Information of China (English)

    PAN Rui-Qin

    2011-01-01

    Temperature and diameter dependence of the thermal conductivity of several armchair single-walled carbon nan-otubes (SWNTs) are studied by nonequilibrium molecular dynamics method with Brenner II potential. The thermal conductivities are calculated at temperatures from WOK to 600K. It is found that the thermal conductivity decreases as the temperature increases and increases as the diameter of SWNT increases. The results demonstrate that these two phenomena are due to the onset of the Umklapp process.%@@ Temperature and diameter dependence of the thermal conductivity of several armchair single-walled carbon nan- otubes (SWNTs) are studied by nonequilibrium molecular dynamics method with Brenner Ⅱ potential.The thermal conductivities are calculated at temperatures from 100K to 600K.It is found that the thermal con- ductivity decreases as the temperature increases and increases as the diameter of SWNT increases.The results demonstrate that these two phenomena are due to the onset of the Umklapp process.

  18. Two-phase flow patterns for flow condensation in small-diameter tubes

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Two-phase flow patterns have been observed visually to investigate the effects of tube diameter, mass flux and tube inclination on flow condensation in small-diameter tubes. For horizontal or inclined small-diameter tubes, gravity-domination is decreased by shear stress and surface tension on phase change interface, which weakens the stratification of condensate and vapor flow due to the action of gravity perpendicular to flow direction. As decreasing the tube diameter from 5.79 mm to 2.18 mm, the annular or sub-annular flows become prevailing in flow regime map. The existing flow regime maps for macro scale cannot predict the experimental data in the present study.

  19. Superhydrophobic modification fails to improve the performance of small diameter expanded polytetrafluoroethylene vascular grafts

    NARCIS (Netherlands)

    Toes, GJ; van Muiswinkel, KW; van Oeveren, W; Suurmeijer, AJH; Timens, W; Stokroos, [No Value; van den Dungen, JJAM

    To determine whether superhydrophobic modification of small diameter expanded polytetrafluoroethylene (ePTFE) vascular grafts improves the performance of these grafts, we assessed neointima formation and platelet deposition in standard and superhydrophobic modified ePTFE grafts. Standard and

  20. Effect of diameter and surface roughness on ultrasonic properties of GaAs nanowires

    Science.gov (United States)

    Dhawan, Punit Kumar; Wan, Meher; Verma, S. K.; Pandey, D. K.; Yadav, R. R.

    2015-02-01

    Second and third order elastic constants of GaAs Nanowires (NWs) are calculated using the many-body interaction potential model. The velocities of ultrasonic waves at different orientations of propagation with unique axis are evaluated using the second order elastic constants. The ultrasonic attenuation and thermal relaxation times of the single crystalline GaAs-NW are determined as a function of diameter and surface roughness by means of Mason theoretical approach using the thermal conductivity and higher order elastic constants. The diameter variation of ultrasonic attenuation and thermal relaxation exhibit second order polynomial function of diameter. It is also found that ultrasonic attenuation and thermal relaxation follow the exponential decay with the surface roughness for GaAs-NW due to reduction in thermal conductivity caused by dominance of surface asperities. Finally, the correlations among ultrasonic parameters, thermal conductivity, surface roughness, and diameter for GaAs-NWs are established leading towards potential applications.

  1. Estimates of Radiation Dose Rates Near Large Diameter Sludge Containers in T Plant

    CERN Document Server

    Himes, D A

    2002-01-01

    Dose rates in T Plant canyon during the handling and storage of large diameter storage containers of K Basin sludge were estimated. A number of different geometries were considered from which most operational situations of interest can be constructed.

  2. The relationship between association of microalbuminuria and retinal vessel diameter in population with essential hypertension

    Institute of Scientific and Technical Information of China (English)

    黄秋霞

    2013-01-01

    Objective To investigate the association of urinary albumin-to-creatinine ratio(UACR) and the diameter of retinal vessel in population with essential hypertension inFujian coastal area.Methods Central retinal artery and

  3. Modeling diameter distribution of the broadleaved-Korean pine mixed forest on Changbai Mountains of China

    Institute of Scientific and Technical Information of China (English)

    WANG Shunzhong; DAI Limin; LIU Guohua; YUAN Jianqiong; ZHANG Hengmin; WANG Qingli

    2006-01-01

    The broadleaved-Korean pine mixed forest is a native vegetation in the Changbai Mountains, northeast China. The probability density functions including the normal, negative exponential, Weibull and finite mixture distribution, were used to describe the diameter distributions of the species groups and entire forest stand. There is a strong correlation between parameters and mean DBH except the shape parameters in the mixture distribution. The diameter classes of species and entire forest stand showed not negative exponential but normal and "S" distribution. The mixture function was better than normal and Weibull to describe the model distribution. The location parameter had an effect on the estimated frequency in the first diameter class, when the estimated location parameter was bigger than the lower limit of the first diameter class.

  4. Analysis of concentration characteristics in ultrasonic atomization by droplet diameter distribution.

    Science.gov (United States)

    Yasuda, Keiji; Bando, Yoshiyuki; Yamaguchi, Soyoko; Nakamura, Masaaki; Oda, Akiyoshi; Kawase, Yasuhito

    2005-01-01

    The droplet diameter distribution and concentration characteristics in ultrasonic atomization were experimentally studied. The samples were aqueous solutions of methanol, ethanol and 1-propanol. The diameter distribution of atomized droplets showed the normal distribution, and the median diameter and standard deviation were expressed by means of the ultrasonic condition and the liquid properties. The concentration characteristic in ultrasonic atomization was analyzed by using the model of shell and core to the atomized droplet, where the former and latter consist of solute and solution, respectively. The value, which was surface solute amount in droplet multiplied by the molecular volume, increased with increasing solute molar fraction in bulk liquid and was independent of alcohol kinds. The rate of accompanying liquid and the solute molar fraction in accompanied liquid were estimated from the diameter distribution and the surface solute amount in droplet.

  5. Quantitative measurement of changes in retinal vessel diameter in ocular fundus images

    DEFF Research Database (Denmark)

    Pedersen, Lars; Grunkin, Michael; Ersbøll, Bjarne Kjær

    2000-01-01

    The change in diameter of retinal vessels as a function of increasing distance to the optic disc is believed to be indicative of the risk level of various vascular diseases such as generalised arteriosclerosis and Diabetes Mellitus. In particular, focal arteriolar narrowing (FAN) is considered...... related to;arteriosclerosis. The aim of this work is to develop methods to provide quantitative information about the FAN status of retinal arteriolar vessel segments. We propose a method to measure the vessel diameter and changes herein along the vessel. The width or diameter measurement is based...... of variance (CV) to estimate the FAN in a vessel segment. The NAG is designed to detect increases in the vessel diameter as the distance to the papilla increases. The performance of the methods developed is compared to the evaluation by a skilled ophthalmologist. The methods are seen to perform well. (C) 2000...

  6. Hypervelocity impact on brittle materials of semi-infinite thickness: fracture morphology related to projectile diameter

    Science.gov (United States)

    Taylor, Emma A.; Kay, Laurie; Shrine, Nick R. G.

    Hypervelocity impact on brittle materials produces features not observed on ductile targets. Low fracture toughness and high yield strength produce a range of fracture morphologies including cracking, spallation and shatter. For sub-mm diameter projectiles, impact features are characterised by petaloid spallation separated by radial cracks. The conchoidal or spallation diameter is a parameter in current cratering equations. An alternative method for interpreting hypervelocity impacts on glass targets of semi-infinite thickness is tested against impact data produced using the Light Gas Gun (LGG) facility at the University of Kent at Canterbury (UKC), U.K. Spherical projectiles of glass and other materials with diameters 30-300 μm were fired at ~5 km s^-1 at a glass target of semi-infinite thickness. The data is used to test a power law relationship between projectile diameter and crack length. The results of this work are compared with published cratering/spallation equations for brittle materials.

  7. Ecological importance of large-diameter trees in a temperate mixed-conifer forest.

    Science.gov (United States)

    Lutz, James A; Larson, Andrew J; Swanson, Mark E; Freund, James A

    2012-01-01

    Large-diameter trees dominate the structure, dynamics and function of many temperate and tropical forests. Although both scaling theory and competition theory make predictions about the relative composition and spatial patterns of large-diameter trees compared to smaller diameter trees, these predictions are rarely tested. We established a 25.6 ha permanent plot within which we tagged and mapped all trees ≥1 cm dbh, all snags ≥10 cm dbh, and all shrub patches ≥2 m(2). We sampled downed woody debris, litter, and duff with line intercept transects. Aboveground live biomass of the 23 woody species was 507.9 Mg/ha, of which 503.8 Mg/ha was trees (SD = 114.3 Mg/ha) and 4.1 Mg/ha was shrubs. Aboveground live and dead biomass was 652.0 Mg/ha. Large-diameter trees comprised 1.4% of individuals but 49.4% of biomass, with biomass dominated by Abies concolor and Pinus lambertiana (93.0% of tree biomass). The large-diameter component dominated the biomass of snags (59.5%) and contributed significantly to that of woody debris (36.6%). Traditional scaling theory was not a good model for either the relationship between tree radii and tree abundance or tree biomass. Spatial patterning of large-diameter trees of the three most abundant species differed from that of small-diameter conspecifics. For A. concolor and P. lambertiana, as well as all trees pooled, large-diameter and small-diameter trees were spatially segregated through inter-tree distances trees and spatial relationships between large-diameter and small-diameter trees. Long-term observations may reveal regulation of forest biomass and spatial structure by fire, wind, pathogens, and insects in Sierra Nevada mixed-conifer forests. Sustaining ecosystem functions such as carbon storage or provision of specialist species habitat will likely require different management strategies when the functions are performed primarily by a few large trees as opposed to many smaller trees.

  8. Serial Measurements of Splanchnic Vein Diameters in RatsUsing High-Frequency Ultrasound

    Directory of Open Access Journals (Sweden)

    Bridget M Seitz

    2016-05-01

    Full Text Available The purpose of this study was to investigate serial ultrasound imaging in rats as a fully non-invasive method to 1 quantify the diameters of splanchnic veins in real time as an indirect surrogate for the capacitance function of those veins, and 2 assess the effects of drugs on venous dimensions. A 21 MHz probe was used on anesthetized male Sprague-Dawley rats to collect images containing the portal vein (PV, superior mesenteric vein (SMV, abdominal inferior vena cava (IVC, and splenic vein (SpV; used as a landmark in timed studies and the abdominal aorta (AA. Stable landmarks were established that allowed reproducible quantification of cross-sectional diameters within an animal. The average diameters of vessels measured every 5 minutes over 45 minutes remained within 0.75±0.15% (PV, 0.2±0.09% (SMV, 0.5±0.12% (IVC and 0.38±0.06% (AA of baseline (PV: 2.0±0.12 mm; SMV: 1.7±0.04 mm; IVC: 3.2±0.1 mm; AA: 2.3±0.14 mm. The maximal effects of the vasodilator sodium nitroprusside (SNP; 2 mg/kg, i.v. bolus on venous diameters were determined 5 minutes post SNP bolus; the diameters of all noted veins were significantly increased by sodium nitroprusside, while mean arterial pressure decreased 29±4 mmHg. By contrast, administration of the venoconstrictor sarafotoxin (S6c; 5 ng/kg, i.v. bolus significantly decreased PV and SpV, but not IVC, SMV or AA, diameters 5 minutes post S6c bolus; mean arterial pressure increased by 6±2 mmHg. In order to determine if resting splanchnic vein diameters were stable over much longer periods of time, vessel diameters were measured every two weeks for 8 weeks. Measurements were found to be highly reproducible within animals over this time period. Finally, to evaluate the utility of vein imaging in a chronic condition, images were acquired from 4-week deoxycorticosterone acetate salt (DOCA-salt hypertensive and normotensive (SHAM control rats. All vessel diameters increased from baseline while mean arterial pressure

  9. The vertical shaft construction technology of cutter head transformation of large diameter shield

    Institute of Scientific and Technical Information of China (English)

    He Feng; Wang Ying; Wang Zhenfei; Wang Baiquan

    2012-01-01

    Taking vertical shaft construction of cutter transformation of the Beijing underground diameter shield for ex- ample, the design and construction of cutter structure transformation under complex boundary conditions for large diameter shield were discussed. Practice about how to ensure the structure safety of the shaft as well as well-coordinated shield construction was explored, and reliable solutions were provided successfully, which can provide reference for similar projects.

  10. NON DESTRUCTIVE EVALUATION OF HEARTWOOD DIAMETER AT BREAST HEIGHT FOR EUCALYPTUS GLOBULUS AND POPULUS EURAMERICANA HYBRID

    OpenAIRE

    Hugo Alexandre Jóia; Teresa Fonseca; Maria Emília Silva; Carlos Pacheco Marques

    2006-01-01

    The objective of this study was the evaluation of the heartwood diameter (dcerne) at breast height on stand trees, for Eucalyptus globulus Labill and the hybrid Populus euramericana. The data used was collected in eucalyptus and popular pure plantations in Central and North Portugal.The non destructive methods tested in the evaluation of heartwood diameter at breast height were [1] visual identification of the heartwood on core samples and [2] indirect estimation using mathematic models. The...

  11. Filmwise Condensation on Low Integral-Fin Tubes of Different Diameter

    Science.gov (United States)

    1988-12-01

    41 5.1 SUMMARY OF SIEDER -TATE COEFFICIENTS ......................... 60 5.2 SUMMARY OF R- 113...smooth tube (m 2 ) Ci Sieder -Tate-type coefficient Cp specific heat at constant pressure (J/kg K) Df fin diameter (m) Dr root diameter (m) e fin height (m...coefficients be known. During this study, 46 Sieder -Tate -type and Nusselt-type equations were used to represent the inside and outside, respectively. ko.14

  12. Annular Pulse Shaping Technique for Large-Diameter Kolsky Bar Experiments on Concrete

    Science.gov (United States)

    2014-10-01

    lt ag e (V ) Time (microsecond) Fig. 5 Linear incident wave generated using an annular copper pulse shaper (O.D. = 25.4 mm, I.D. = 14.4 mm). Note that...AFRL-RW-EG-TP-2014-005 Annular Pulse Shaping Technique for Large- Diameter Kolsky Bar Experiments on Concrete...NUMBER (Include area code) 13-6-2014 Technical Publication October 2012 - February 2014 ANNULAR PULSE SHAPING TECHNIQUE FOR LARGE-DIAMETER KOLSKY BAR

  13. Experimental and Numerical Investigation of a 60cm Diameter Bladeless Fan

    OpenAIRE

    mohammad jafari; Hossein Afshin; Bijan Farhanieh; Hamidreza bozorgasareh

    2016-01-01

    Bladeless fan is a novel type of fan with an unusual geometry and unique characteristics. This type of fan has been recently developed for domestic applications in sizes typically up to 30cm diameter. In the present study, a Bladeless fan with a diameter of 60cm was designed and constructed, in order to investigate feasibility of its usage in various industries with large dimensions. Firstly, flow field passed through this fan was studied by 3D modeling. Aerodynamic and aeroacoust...

  14. The first observations of oocyte diameters for the pipefish from the southern Black Sea

    OpenAIRE

    GÜRKAN, Şule; Taylan, Burcu

    2013-01-01

    Abstract Syngnathid specimens sample between July 2001˗May 2002 was examined about measurements of oocyte diameter in the coastal waters of Sinop peninsula, southern Back Sea. The specimens of Syngnathid fishes (Syngnathus acus, Syngnathus typhle, Syngnathus variegatus, Syngnathus tenuirostris, Nerophis ophidion) catched with using hand dredge from the vegetated coastal area. According to results, the mean of hydrated oocyte diameter was calculated as, respectively: Syngnathus acus: 1.96 mm, ...

  15. Distal Ureteral Diameter Ratio is Predictive of Breakthrough Febrile Urinary Tract Infection.

    Science.gov (United States)

    Arlen, Angela M; Leong, Traci; Guidos, Paul J; Alexander, Siobhan E; Cooper, Christopher S

    2017-07-08

    Distal ureteral diameter ratio is an objective measure that is prognostic of spontaneous resolution of vesicoureteral reflux. Along with likelihood of resolution, improved identification of children at risk for recurrent febrile urinary tract infections may impact management decisions. We evaluated the usefulness of ureteral diameter ratio as a predictive factor for breakthrough febrile urinary tract infections. Children with primary vesicoureteral reflux and detailed voiding cystourethrogram were identified. Ureteral diameter ratio was computed by measuring largest ureteral diameter within the pelvis and dividing by the distance between L1 and L3 vertebral bodies. Demographics, vesicoureteral reflux grade, laterality, presence/absence of bladder-bowel dysfunction, and ureteral diameter ratio were tested in univariate and multivariable analyses. Primary outcome was breakthrough febrile urinary tract infections. We analyzed 112 girls and 28 boys with a mean ± SD age of 2.5 ± 2.3 years at diagnosis. Vesicoureteral reflux was grade 1 to 2 in 64 patients (45.7%), grade 3 in 50 (35.7%), grade 4 in 16 (11.4%) and grade 5 in 10 (7.2%). Mean ± SD followup was 3.2 ± 2.7 years. A total of 40 children (28.6%) experienced breakthrough febrile urinary tract infections. Ureteral diameter ratio was significantly greater in children with (0.36) vs without (0.25) breakthrough febrile infections (p = 0.004). Controlling for vesicoureteral reflux grade, every 0.1 U increase in ureteral diameter ratio resulted in 1.7 times increased odds of breakthrough infection (95% CI 1.24 to 2.26, p urinary tract infections independent of reflux grade. Ureteral diameter ratio provides valuable prognostic information about risk of recurrent pyelonephritis and may assist with clinical decision-making. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. Atomistic Failure Mechanism of Single Wall Carbon Nanotubes with Small Diameters

    Institute of Scientific and Technical Information of China (English)

    JI Dong; GAO Xiang; KONG Xiang-Yang; LI Jia-Ming

    2007-01-01

    @@ Single wall carbon nanotubes with small diameters (< 5.0 (A)) subjected to bending deformation are simulated by orthogonal tight-binding molecular dynamics approach. Based on the calculations of C-C bond stretching and breaking in the bending nanotubes, we elucidate the atomistic failure mechanisms of nanotube with small diameters. In the folding zone of bending nanotube, a large elongation of C-C bonds occurs, accounting for the superelastic behaviour.

  17. Estimation of vessel diameter and blood flow dynamics from laser speckle images

    DEFF Research Database (Denmark)

    Postnov, Dmitry D.; Tuchin, Valery V.; Sosnovtseva, Olga

    2016-01-01

    Laser speckle imaging is a rapidly developing method to study changes of blood velocity in the vascular networks. However, to assess blood flow and vascular responses it is crucial to measure vessel diameter in addition to blood velocity dynamics. We suggest an algorithm that allows for dynamical...... masking of a vessel position and measurements of it's diameter from laser speckle images. This approach demonstrates high reliability and stability....

  18. Determination of Diameter and Index of Refraction of Textile Fibers by Laser Backscattering

    Energy Technology Data Exchange (ETDEWEB)

    H. Okuda; B. Stratton; L. Meixler; P. Efthimion; D.Mansfield

    2003-07-24

    A new method was developed to determine both diameters and indices of refraction and hence the birefringence of cylindrical textile and industrial fibers and bundles by measuring intensity patterns of the scattered light over an interval of scattering angles. The measured intensity patterns are compared with theoretical predictions (Mie theory) to determine fiber diameter and index of refraction. It is shown that the method is simple and accurate and may be useful as an on-line, noncontact diagnostic tool in real time.

  19. STUDY OF VARIATION OF THE DIAMETER OF THE SPINAL CANAL AND THE FORAMINA IN SPONDYLOLISTHESIS

    Directory of Open Access Journals (Sweden)

    Enguer Beraldo Garcia

    2016-03-01

    Full Text Available ABSTRACT Objective: To define and quantify the degree of change of the spinal canal diameter in patients with degenerative and spondylolytic spondylolisthesis. Methods: We studied CT scans of 54 patients. Of this total, 37 (29 women and 8 men had degenerative type and 17 (7 women and 10 men had spondylolytic type. Results: In the degenerative spondylolisthesis group, the average diameter of the spinal canal at the injured vertebra level was 17.35 mm and 17.64 mm for the upper vertebra level. The average diameter of the foramen at the level of the affected vertebra was 14.61 mm to left side and 15.00 mm to the right side. The average diameter of the foramen at the upper vertebra level was 16.82 mm to the left side and 16.51 mm to the right side. In the spondylolytic group, the average diameter of the spinal canal at the level of the affected vertebra was 23.25 mm and at the upper vertebra level was 18.66 mm. The average diameter of the foramen at the level of the affected vertebra was 11.98 mm to the left side and 12.34 mm to the right side. The average diameter of the foramen at the level of the upper vertebra was 16.97 mm to the left side and 15.58 mm to the right side. Conclusion: The diameter of the spinal canal in the sagittal plane showed no statistically significant increase in the spondylolytic spondylolisthesis group, in contrast to what is found in the degenerative spondylolisthesis group. It was also observed a reduction in vertebral foramina of the injured level in both groups.

  20. Smart aircraft composite structures with embedded small-diameter optical fiber sensors

    Science.gov (United States)

    Takeda, Nobuo; Minakuchi, Shu

    2012-02-01

    This talk describes the embedded optical fiber sensor systems for smart aircraft composite structures. First, a summary of the current Japanese national project on structural integrity diagnosis of aircraft composite structures is described with special emphasis on the use of embedded small-diameter optical fiber sensors including FBG sensors. Then, some examples of life-cycle monitoring of aircraft composite structures are presented using embedded small-diameter optical fiber sensors for low-cost and reliable manufacturing merits.

  1. The influence of upper airways diameter on the intensity of obstructive sleep apnea

    Directory of Open Access Journals (Sweden)

    Jolanta Szymańska

    2014-03-01

    Full Text Available Introduction and Objective. Obstructive sleep apnea (OSA is characterized by at least 5 ten-second-long episodes of apnea or hypopnea, per hour of sleep. This disease may lead to severe, life-threatening complications. Therefore, risk analysis and its influence on disease intensity is crucial for proper implementation of preventive treatments. Objective. To determine the relation between the intensity of OSA expressed in Apnea-Hypopnea Index (AHI, and the anterior-posterior diameter of upper airways at the levels of soft palate and tongue base. Material and Method. Medical records of 41 patients with sleep apnea (AHI>4 diagnosed through polysomnographic examination obstructive were used for the study. The data consisted of: age and gender, polysomnographic examination results (AHI, lateral cephalogram with cephalomertic analysis, together with measurements of the upper and lower pharyngeal depth according to McNamara. Statistical analysis was carried out in accordance with Pearson’s r correlation coefficient test (Statistica 8.0 software package. Results. Analysis of the influence of upper airways diameter on the intensity of OSA showed that the value of upper Airways diameter at the tongue base level had no statistically significant impact on the value of AHI (p=0.795. However, a statistically significant impact of the value of upper airways diameter on the AHI value (p=0.008 at the soft palate level was observed. Patients with OSA have narrowed upper airways diameter. The value of AHI increases with the decrease of upper diameter and is not dependent on a lower diameter value. Patients with a decreased upper airways diameter should be informed about potential breathing disorders during sleep.

  2. Change in efficiency of aspheric intraocular lenses based on pupil diameter.

    Science.gov (United States)

    Eom, Youngsub; Yoo, Eunjoo; Kang, Su-Yeon; Kim, Hyo-Myung; Song, Jong-Suk

    2013-03-01

    To measure the effect of spherical aberration correction by aspheric intraocular lenses (IOLs) based on pupil diameter, and to determine the minimum pupil diameter for each aspheric IOL. Retrospective cross-sectional study. Eight-six patients (169 eyes) who were implanted with a HOYA AF-1 NY-60 (HOYA Corporation) or Tecnis ZCB00 1-piece IOL (Abbott Medical Optics Inc) were enrolled. Ocular, corneal, and internal spherical aberrations were measured at the 1-month postoperative visit using the Wavefront Analyzer KR-1W (Topcon). Minimum pupil diameter, which is required for each aspheric IOL to be effective, was calculated using a regression equation. The mean value of internal spherical aberration of the Tecnis ZCB00 group (-0.09 ± 0.094 μm) was lower than that of the HOYA NY-60 group (-0.05 ± 0.072 μm) (P = .005). The original negative spherical aberrations of the HOYA NY-60 (-0.18 μm) were measured at a pupil diameter of 5.6 mm, and for the Tecnis ZCB00 (-0.27 μm) at a pupil diameter of 6.1 mm. The aspheric IOL efficiency dropped to 0% when the pupil diameter was 3.47 mm for the Tecnis ZCB00 group and 3.71 mm for the HOYA NY-60 group. When the pupil diameters of patients are smaller than 3.4 mm for the Tecnis ZCB00 and 3.7 mm for the HOYA NY-60, the spherical aberration correction using these aspheric IOLs seems to be ineffective. Approximately 10% of the eyes showed smaller pupil size than the minimum effective diameter under mesopic conditions. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Woodland: Dynamics of Deciduous Tree Stand Average Diameters of the Principal Forest Types

    Directory of Open Access Journals (Sweden)

    R. A. Ziganshin

    2014-06-01

    Full Text Available The analysis of age dynamics of average diameters of a deciduous tree stands of different forest types at Highland Khamar-Daban (natural woodland in South-East Baikal Lake region has been done. The aggregate data of average tree stand diameters by age classes, as well as tree stand current periodic and overall average increment are presented and discussed in the paper. Forest management appraisal is done.

  4. Computer Vision Approach for Low Cost, High Precision Measurement of Grapevine Trunk Diameter in Outdoor Conditions

    OpenAIRE

    Pérez, Diego Sebastián; Bromberg, Facundo; Antivilo, Francisco Gonzalez

    2014-01-01

    Trunk diameter is a variable of agricultural interest, used mainly in the prediction of fruit trees production. It is correlated with leaf area and biomass of trees, and consequently gives a good estimate of the potential production of the plants. This work presents a low cost, high precision method for the measurement of trunk diameter of grapevines based on Computer Vision techniques. Several methods based on Computer Vision and other techniques are introduced in the literature. These metho...

  5. Measurement of the aortic diameter in the asymptomatic Korean population: Assessment with multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Hwan; Lee, Whal; Choi, Hyuck Jae; Kim, Dae Jin; Park, Eun Ah; Chung, Jin Wook; Park, Jae Hyung [Dept. of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2013-08-15

    To determine normal reference values for aortic diameters in asymptomatic Korean adults. Three hundred adults without signs or symptoms of cardiovascular diseases were enrolled in this study. Aortic diameters were measured at nine predetermined levels on CT images. Aortic diameter measurements were adjusted for body surface area. Analysis of data was performed with regard to age, sex, weight, height and hypertension. Aortic diameters were 2.99 ± 0.57 cm at the ascending aorta, 2.54 ± 0.35 cm at the transverse aortic arch, 2.36 ± 0.35 cm at the proximal descending thoracic aorta (DTA), 2.23 ± 0.37 cm at the mid DTA, 2.17 ± 0.38 cm at the distal DTA, 2.16 ± 0.37 cm at the thoracoabdominal junction, 2.10, 00B1, 0.35 cm at the level of the celiac axis, 1.94, 00B1, 0.36 cm at the suprarenal aorta, 1.58 ± 0.24 cm at the aortic bifurcation. Men had slightly larger diameters than women (p < 0.05). All diameters increased with age and hypertension, with statistical significance (p < 0.01). And all aortic diameters increased with height (p < 0.05) except at the level of the aortic arch (p = 0.056), and increased with weight (p < 0.05) except at the level of the suprarenal aorta (p = 0.067). Male sex, higher weight and height, age and hypertension are associated with larger aortic diameters in asymptomatic Korean adults.

  6. An Approach to Stability Analysis of Embedded Large-Diameter Cylinder Quay

    Institute of Scientific and Technical Information of China (English)

    王元战; 祝振宇

    2002-01-01

    The large-diameter cylinder structure, which is made of large successive bottomless cylinders placed on foundationbed or partly driven into soil, is a recently developed retaining structure in China. It can be used in port, coastal and off-shore works. The method for stability analysis of the large-diameter cylinder structure, especially for stability analysis ofthe embedded large-diameter cylinder structure, is an important issue. In this paper, an idea is presented that is, em-bedded large-diameter cylinder quays can be divided into two types, i.e. the gravity wall type and the cylinder pile walltype. A method for stability analysis of the large-diameter cylinder quay of the cylinder pile wall type is developed and amethod for stability analysis of the large-diameter cylinder quay of the gravity wall type is also proposed. The effect of sig-nificant parameters on the stability of the large-dianeter cylinder quay of the cylinder pile wall type is investigated throughnumerical calculation.

  7. MreB helical pitch angle determines cell diameter in Escherichia coli

    CERN Document Server

    Ouzounov, Nikolay; Bratton, Benjamin; Jacobowitz, David; Gitai, Zemer; Shaevitz, Joshua W

    2015-01-01

    Bacteria have remarkably robust cell shape control mechanisms. For example, cell diameter only varies by a few percent across a population. MreB is necessary for establishment and maintenance of rod shape although the mechanism of shape control remains unknown. We perturbed MreB in two complimentary ways to produce steady-state cell diameters over a wide range, from 790+/-30 nm to 1700+/-20 nm. To determine which properties of MreB are important for diameter control, we correlated structural characteristics of fluorescently-tagged MreB polymers with cell diameter by simultaneously analyzing 3-dimensional images of MreB and cell shape. Our results indicate that the pitch angle of MreB inversely correlates with cell diameter. Other correlations are not found to be significant. These results demonstrate that the physical properties of MreB filaments are important for shape control and support a model in which MreB dictates cell diameter and organizes cell wall growth to produce a chiral cell wall.

  8. Narrowing SWNT diameter distribution using size-separated ferritin-based Fe catalysts.

    Science.gov (United States)

    Durrer, Lukas; Greenwald, Jason; Helbling, Thomas; Muoth, Matthias; Riek, Roland; Hierold, Christofer

    2009-09-02

    Sensors and devices made from single-walled carbon nanotubes (SWNTs) are most often electrically probed through metal leads contacting the semiconducting SWNTs (s-SWNTs). Contact barriers in general and Schottky barriers (SBs) in particular are usually obtained at a metal-semiconductor interface. The unique one-dimensional structure (1D) of SWNTs allows tailoring of the SB heights through the contact metal type and the size of the s-SWNT bandgap. A large workfunction reduces the SB height (e.g. using Pd as the metal contact material). The bandgap of an SWNT is inversely proportional to its diameter. Ohmic contacts--the preferable choice--are achieved for s-SWNTs with diameters greater than 2 nm on Pd metal leads. SWNT device reproducibility, on the other hand, requires a narrow distribution of the SWNT diameters. Here, we present a method to fabricate SWNTs with a large and adjustable mean diameter (1.9-2.4 nm) and very narrow diameter distribution (+/- 0.27 nm at mean diameter 1.9 nm). The results are achieved through a size separation of the ferritin catalyst particles by sedimentation velocity centrifugation prior to their use in the chemical vapor deposition (CVD) formation of SWNTs.

  9. Narrowing SWNT diameter distribution using size-separated ferritin-based Fe catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Durrer, Lukas; Helbling, Thomas; Muoth, Matthias; Hierold, Christofer [Micro and Nanosystems, Department of Mechanical and Process Engineering, ETH Zuerich, CH-8092 Zurich (Switzerland); Greenwald, Jason; Riek, Roland, E-mail: lukas.durrer@micro.mavt.ethz.c [Laboratory of Physical Chemistry, ETH Zurich, CH-8093 Zuerich (Switzerland)

    2009-09-02

    Sensors and devices made from single-walled carbon nanotubes (SWNTs) are most often electrically probed through metal leads contacting the semiconducting SWNTs (s-SWNTs). Contact barriers in general and Schottky barriers (SBs) in particular are usually obtained at a metal-semiconductor interface. The unique one-dimensional structure (1D) of SWNTs allows tailoring of the SB heights through the contact metal type and the size of the s-SWNT bandgap. A large workfunction reduces the SB height (e.g. using Pd as the metal contact material). The bandgap of an SWNT is inversely proportional to its diameter. Ohmic contacts-the preferable choice-are achieved for s-SWNTs with diameters greater than 2 nm on Pd metal leads. SWNT device reproducibility, on the other hand, requires a narrow distribution of the SWNT diameters. Here, we present a method to fabricate SWNTs with a large and adjustable mean diameter (1.9-2.4 nm) and very narrow diameter distribution ({+-} 0.27 nm at mean diameter 1.9 nm). The results are achieved through a size separation of the ferritin catalyst particles by sedimentation velocity centrifugation prior to their use in the chemical vapor deposition (CVD) formation of SWNTs.

  10. Common Carotid Artery Diameter and Cardiovascular Risk Factors in Overweight or Obese Postmenopausal Women

    Directory of Open Access Journals (Sweden)

    Kelly D. Lloyd

    2012-01-01

    Full Text Available Arterial diameter is an underutilized indicator of vascular health. We hypothesized that interadventitial and lumen diameter of the common carotid artery would be better indicators of vascular health than carotid plaque or intima media thickness (IMT. Participants were 491 overweight or obese, postmenopausal women who were former or current hormone therapy (HT users, 52–62 years, with waist circumference >80 cm. We evaluated cross-sectional associations of cardiovascular risk factors with carotid measures, by HT status. Former HT users had a worse cardiovascular profile than current HT users: larger adventitial (6.94 mm versus 6.79 mm and lumen diameter (5.44 mm versus 5.31 mm, both P<0.01 independent of cardiovascular risk factors; IMT and plaque were similar. Larger diameters were best explained by former HT use, higher pulse pressure, and greater weight. Independent of potential confounders, overweight and obese postmenopausal former HT users had larger carotid diameters than current HT users. Carotid diameter should be considered in studies of HT.

  11. Fabrication of diameter-modulated and ultrathin porous nanowires in anodic aluminum oxide templates

    Energy Technology Data Exchange (ETDEWEB)

    Sulka, Grzegorz D., E-mail: Sulka@chemia.uj.edu.pl [Max Planck Institute of Microstructure Physics, Weinberg 2, 06120 Halle (Germany); Department of Physical Chemistry and Electrochemistry, Jagiellonian University, Ingardena 3, 30060 Krakow (Poland); Brzozka, Agnieszka [AGH University of Science and Technology, Faculty of Non-Ferrous Metals, Al. Mickiewicza 30, Krakow 30-059 (Poland); Liu, Lifeng [Max Planck Institute of Microstructure Physics, Weinberg 2, 06120 Halle (Germany)

    2011-05-30

    Graphical abstract: Display Omitted Highlights: > AAO templates with modulated pore diameter were fabricated by pulse anodization. > HA pulse duration tunes the shape of pores and the structure of AAO channels. > Au, Ag, Ni and Ag-Au diameter-modulated nanowires were synthetized. > Porous ultrathin Au nanowires were obtained by dealloying Ag-Au nanowires. - Abstract: Anodic aluminum oxide (AAO) membranes with modulated pore diameter were synthesized by pulse anodization in 0.3 M sulfuric acid at 1 deg. C. For AAO growth, a typical combination of alternating mild anodizing (MA) and hard anodizing (HA) pulses with applied potential pulses of 25 V and 35 V was applied. The control of the duration of HA pulses will provide an interesting way to tune the shape of pores and the structure of AAO channels. It was found that a non-uniform length of HA segments in cross section of AAO is usually observed when the HA pulse duration is shorter than 1.2 s. The pulse anodization performed with longer HA pulses leads to the formation of AAO templates with periodically modulated pore diameter and nearly uniform length of segments. Various diameter-modulated metallic nanowires (Au, Ag, Ni and Ag-Au) were fabricated by electrodeposition in the pores of anodic alumina membranes. A typical average nanowire diameter was about 30 nm and 48 nm for MA and HA nanowire segments, respectively. After a successful dealloying silver from Ag-Au nanowires, porous ultrathin Au nanowires were obtained.

  12. Angular diameter estimation of interferometric calibrators. Example of λ Gruis, calibrator for VLTI-AMBER

    Science.gov (United States)

    Cruzalèbes, P.; Jorissen, A.; Sacuto, S.; Bonneau, D.

    2010-06-01

    Context. Accurate long-baseline interferometric measurements require careful calibration with reference stars. Small calibrators with high angular diameter accuracy ensure the true visibility uncertainty to be dominated by the measurement errors. Aims: We review some indirect methods for estimating angular diameter, using various types of input data. Each diameter estimate, obtained for the test-case calibrator star λ Gru, is compared with the value 2.71 mas found in the Bordé calibrator catalogue published in 2002. Methods: Angular size estimations from spectral type, spectral index, in-band magnitude, broadband photometry, and spectrophotometry give close estimates of the angular diameter, with slightly variable uncertainties. Fits on photometry and spectrophotometry need physical atmosphere models with “plausible” stellar parameters. Angular diameter uncertainties were estimated by means of residual bootstrapping confidence intervals. All numerical results and graphical outputs presented in this paper were obtained using the routines developed under PV-WAVE®, which compose the modular software suite SPIDAST, created to calibrate and interprete spectroscopic and interferometric measurements, particularly those obtained with VLTI-AMBER. Results: The final angular diameter estimate 2.70 mas of λ Gru, with 68% confidence interval 2.65-2.81 mas, is obtained by fit of the MARCS model on the ISO-SWS 2.38-27.5 μm spectrum, with the stellar parameters Te = 4250 K, log g = 2.0, z = 0.0 dex, M = 1.0 M⊙, and ξ_t = 2.0 km s-1.

  13. Effect of sample diameter on primary dendrite spacing of directionally solidified Al-4%Cu alloy

    Institute of Scientific and Technical Information of China (English)

    QU Min; LIU Lin; TANG Feng-tao; ZHANG Jun; FU Heng-zhi

    2009-01-01

    The relationship between primary dendrite arm spacing and sample diameter was studied during directional solidification for Al-4%Cu (mass fraction) alloy. It is shown that primary dendrite spacing is decreased with the decrease of the sample diameter at given growth rate. By regressing the relationship between primary dendrite arm spacing and the growth rate, the primary dendrite arm spacing complies with 461.76v-0.53, 417.92v-0.28 and 415.83v-0.25 for the sample diameter of 1.8, 3.5 and 7.2 mm, respectively. The primary dendrite spacing, growth rate and thermal gradient for different sample diameters comply with 28.77v-0.35G-0.70, 23.17v-0.35G-0.70 and 23.84v-0.35G-0.70, respectively. They are all consistent with the theoretical model , and b1/a1=2. By analyzing the experimental results with classical models, it is shown that KURZ-FISHER model fits for the primary dendrite spacing in smaller sample diameters with weaker thermosolute convection. Whereas TRIVEDI model is suitable for describing primary dendrite arm spacing with a larger diameter (d>2 mm) where convection should be considered.

  14. Rubbing test responses of the skin to man-made mineral fibres of different diameters.

    Science.gov (United States)

    Stam-Westerveld, E B; Coenraads, P J; van der Valk, P G; de Jong, M C; Fidler, V

    1994-07-01

    The irritant potency of 5 types of insulation wools (2 types of rockwool and 3 types of glasswool) were studied on the basis of their differences in diameter by a standardized rubbing test. Assessment was done by laser Doppler flowmetry (LDF) and erythema scores. Insulation wools show a wide distribution of the diameter around the mean. Of the rockwool material, 30% consisted of small grains, called "shot". The control test site did not change over time; thus, the rubbing procedure itself does not seem to contribute to the skin reactions. All fibre types proved to be irritant to the skin. The irritant reactions did not correspond with the mean diameter, although the fibre type with the smallest diameter was the least irritant and the fibre type with the largest diameter the strongest. The presence of "shot" had a significant effect on the LDF responses. "Shot" and the distribution around the mean diameter may play a role in eliciting the skin irritation by insulation wools.

  15. Transabdominal ultrasound measurement of rectal diameter is dependent on time to defecation in constipated children

    DEFF Research Database (Denmark)

    Modin, Line; Dalby, Kasper; Walsted, Anne-Mette;

    2015-01-01

    AIM: To study whether diurnal variations and time in relation to defecation has to be taken into account when measurements of rectal diameter are used to determine faecal impaction in constipated children. METHODS: Repeated ultrasound measures of rectal diameter were performed in 28 children (14...... constipated/14 healthy, aged between 4 and 12 years) every third hour during 24 h. After defecation, three additional scans were performed at 1-h intervals. RESULTS: No diurnal variation in rectal diameter was found in the healthy group. In the constipated group, mean rectal diameter was significantly larger...... at 2 pm (P = 0.038) and 5 pm (P = 0.006). There were significant differences between rectal diameter in the healthy group and the constipated group at 2 pm (P = 0.016) and 5 pm (P = 0.027). When we omitted the rectal diameter of five constipated children who had their first bowel movement after 5 pm...

  16. Variations of fine root diameter with root order in Manchurian ash and Dahurian larch plantations

    Institute of Scientific and Technical Information of China (English)

    WANG Xiangrong; WANG Zhengquan; HAN Youzhi; GU Jiacun; GUO Dali; MEI Li

    2007-01-01

    Fine root lifespan and turnover play an important role in carbon allocation and nutrient cycling in forest ecosystems.Fine roots are typically defined as less than 1 or 2mm in diameter.However,when categorizing roots by this diameter size,the position of an individual root on the complex lateral branching pattern has often been ignored,and our knowledge about relationships between branching order and root function thus remains limited.More recently,studies on root survivals found that longevity was remarkably different in the same branching level due to diameter variations.The objectives of this study were:(1) To examine variations of fine root diameter from the first-to fifth-orders in Fraxinus mandshurica Rupr and Larix gmelinii Rupr roots;and (2) To reveal how the season,soil nutrient,and water availability affect root diameter in different branch order in two species.This study was conducted at Maoershan Forest Research Station (45°21'-45°25'N,127°30'-127°34'E) owned by Northeast Forestry University in Harbin,northeast China.Both F.mandshurica and L.gmelinii were planted in 1986.In each plantation,fine roots of two species by sampling up to five fine root branch orders three times during the 2003 growing season from two soil depths (i.e.,0-10 and 10-20 cm)were obtained.The results showed that average diameters of fine roots were significantly different among the five branch orders.The first-order had the thinner roots and the fifth order had the thickest roots,the diameter increasing regularly with the ascending branch orders in both species.If the diameter of fine roots was defined as being smaller than 0.5 mm,the first three orders ofF.mandshurica roots and the first two orders of L.gmelinii roots would be included in the fine root population.The diameter ranges of the fine roots from first-order to fifth-order were 0.15-0.58,0.18-0.70,0.26-1.05,0.36-1.43,and 0.71-2.96 mm for F.mandshurica,and 0.17-0.76,0.23-1.02,0.26-1.10,0.38-1.77,and 0.84-2.80 mm for L

  17. Evaluation of the splats properties and relation with droplets diameters in atomization process using a De Laval Nozzle

    Energy Technology Data Exchange (ETDEWEB)

    Planche, Marie-Pierre, E-mail: marie-pierre.planche@utbm.fr [LERMPS-UTBM Site de Sevenans, 90010 Belfort, Cedex (France); Khatim, Othmane; Dembinski, Lucas [LERMPS-UTBM Site de Sevenans, 90010 Belfort, Cedex (France); Bailly, Yannick [Institute FEMTO-ST/ENISYS, University of Franche-Comte, UMR CNRS 6174, 90000 Belfort (France); Coddet, Christian [LERMPS-UTBM Site de Sevenans, 90010 Belfort, Cedex (France)

    2013-01-15

    Properties of the powders developed during atomization process are essentially determined by process parameters. Experiments based on splat collection have been performed at different stages of the process evolution. Formation of splat formed as a result of impingement of the melted metallic droplets onto a substrate was studied. Splat characteristics have been determined from image analysis in function of process parameters and time progress. Droplet diameters were measured using laser Coulter analyzer. Direct relationships between splat diameter and droplet diameter were established. The atomization experiments point out the strong influence of two processing parameters (atomizing gas and melt nozzle diameter) on splat characteristics and particle size. It has been observed that increasing atomizing pressure leads to a decrease of mean splat diameter and width of the size distribution. Similar evolution was found for droplet diameter. Moreover, it is clearly shown that increasing melt nozzle diameter induces an increase of both splat diameters and droplet diameters. The results provide a better understanding of the influence of atomization parameters on the size distribution. Highlights: Black-Right-Pointing-Pointer In this study, changes of splat characteristics were examined versus operating parameters. Black-Right-Pointing-Pointer Splat diameter decreases with the increase of atomizing pressure. Black-Right-Pointing-Pointer Splat diameter decreases with the decrease of the melt nozzle diameter. Black-Right-Pointing-Pointer Changes of droplet diameter are in good agreement with those of splat diameter.

  18. Human intraretinal myelination: Axon diameters and axon/myelin thickness ratios

    Directory of Open Access Journals (Sweden)

    Thomas FitzGibbon

    2013-01-01

    Full Text Available Purpose: Human intraretinal myelination of ganglion cell axons occurs in about 1% of the population. We examined myelin thickness and axon diameter in human retinal specimens containing myelinated retinal ganglion cell axons. Materials and Methods: Two eyes containing myelinated patches were prepared for electron microscopy. Two areas were examined in one retina and five in the second retina. Measurements were compared to normal retinal and optic nerve samples and the rabbit retina, which normally contains myelinated axons. Measurements were made using a graphics tablet. Results: Mean axon diameter of myelinated axons at all locations were significantly larger than unmyelinated axons (P ≤ 0.01. Myelinated axons within the patches were significantly larger than axons within the optic nerve (P < 0.01. The relationship between axon diameter/fiber diameter (the G-ratio seen in the retinal sites differed from that in the nerve. G-ratios were higher and myelin thickness was positively correlated to axon diameter (P < 0.01 in the retina but negatively correlated to axon diameter in the nerve (P < 0.001. Conclusion: Intraretinally myelinated axons are larger than non-myelinated axons from the same population and suggests that glial cells can induce diameter changes in retinal axons that are not normally myelinated. This effect is more dramatic on intraretinal axons compared with the normal transition zone as axons enter the optic nerve and these changes are abnormal. Whether intraretinal myelin alters axonal conduction velocity or blocks axonal conduction remains to be clarified and these issues may have different clinical outcomes.

  19. Influence of caster diameter on the static and dynamic forward stability of occupied wheelchairs.

    Science.gov (United States)

    Kirby, R L; McLean, A D; Eastwood, B J

    1992-01-01

    The hypothesis that the static and dynamic forward stability of an occupied wheelchair would increase as a function of the caster diameter was tested in 20 able-bodied subjects. A device was attached to the wheelchair frame so that casters with different diameters could be used. With platform testing of static stability, the occupied wheelchair equipped with casters with diameters of 10.2, 20.3, 25.4, and 33.0cm, tipped at mean (+/- 1SD) angles of 23.8 degrees (+/- 1.3 degrees), 25.2 degrees (+/- 1.4 degrees), 26.1 degrees (+/- 1.4 degrees), and 28.2 degrees (+/- 1.9 degrees), respectively. The relationship between static stability (y, in degrees) and caster diameter (x, in cm) can be expressed by the equation y = 23.5-.0196 chi + .00484 x2 (p = .0001). Dynamic stability was tested by having subjects descend a 5 degree ramp, by gravity alone, from progressively farther up the ramp until a full forward tip occurred (footrests contacted the floor) when the wheelchair struck a 5-cm-high obstruction with sufficient speed. The mean tipping speeds for the dynamic tests were .85 (+/- .08), .85 (+/- .08), .89 (+/-.07), and 1.04 (+/- .14) m/sec for the wheelchair fitted with the caster diameters ranging from smallest to largest, respectively. The relationship between dynamic stability (y, tipping speed in m/sec) and caster diameter (chi, in cm) can be expressed by the equation y = .788 + .0139 chi-.00110 chi 2 + .0000276 chi 3 (p = .0001). The relationship between caster diameter and forward wheelchair stability should be considered in wheelchair design and prescription.

  20. The importance of large-diameter trees to forest structural heterogeneity.

    Directory of Open Access Journals (Sweden)

    James A Lutz

    Full Text Available Large-diameter trees dominate the structure, dynamics and function of many temperate and tropical forests. However, their attendant contributions to forest heterogeneity are rarely addressed. We established the Wind River Forest Dynamics Plot, a 25.6 ha permanent plot within which we tagged and mapped all 30,973 woody stems ≥ 1 cm dbh, all 1,966 snags ≥ 10 cm dbh, and all shrub patches ≥ 2 m(2. Basal area of the 26 woody species was 62.18 m(2/ha, of which 61.60 m(2/ha was trees and 0.58 m(2/ha was tall shrubs. Large-diameter trees (≥ 100 cm dbh comprised 1.5% of stems, 31.8% of basal area, and 17.6% of the heterogeneity of basal area, with basal area dominated by Tsuga heterophylla and Pseudotsuga menziesii. Small-diameter subpopulations of Pseudotsuga menziesii, Tsuga heterophylla and Thuja plicata, as well as all tree species combined, exhibited significant aggregation relative to the null model of complete spatial randomness (CSR up to 9 m (P ≤ 0.001. Patterns of large-diameter trees were either not different from CSR (Tsuga heterophylla, or exhibited slight aggregation (Pseudotsuga menziesii and Thuja plicata. Significant spatial repulsion between large-diameter and small-diameter Tsuga heterophylla suggests that large-diameter Tsuga heterophylla function as organizers of tree demography over decadal timescales through competitive interactions. Comparison among two forest dynamics plots suggests that forest structural diversity responds to intermediate-scale environmental heterogeneity and disturbances, similar to hypotheses about patterns of species richness, and richness- ecosystem function. Large mapped plots with detailed within-plot environmental spatial covariates will be required to test these hypotheses.

  1. The importance of large-diameter trees to forest structural heterogeneity.

    Science.gov (United States)

    Lutz, James A; Larson, Andrew J; Freund, James A; Swanson, Mark E; Bible, Kenneth J

    2013-01-01

    Large-diameter trees dominate the structure, dynamics and function of many temperate and tropical forests. However, their attendant contributions to forest heterogeneity are rarely addressed. We established the Wind River Forest Dynamics Plot, a 25.6 ha permanent plot within which we tagged and mapped all 30,973 woody stems ≥ 1 cm dbh, all 1,966 snags ≥ 10 cm dbh, and all shrub patches ≥ 2 m(2). Basal area of the 26 woody species was 62.18 m(2)/ha, of which 61.60 m(2)/ha was trees and 0.58 m(2)/ha was tall shrubs. Large-diameter trees (≥ 100 cm dbh) comprised 1.5% of stems, 31.8% of basal area, and 17.6% of the heterogeneity of basal area, with basal area dominated by Tsuga heterophylla and Pseudotsuga menziesii. Small-diameter subpopulations of Pseudotsuga menziesii, Tsuga heterophylla and Thuja plicata, as well as all tree species combined, exhibited significant aggregation relative to the null model of complete spatial randomness (CSR) up to 9 m (P ≤ 0.001). Patterns of large-diameter trees were either not different from CSR (Tsuga heterophylla), or exhibited slight aggregation (Pseudotsuga menziesii and Thuja plicata). Significant spatial repulsion between large-diameter and small-diameter Tsuga heterophylla suggests that large-diameter Tsuga heterophylla function as organizers of tree demography over decadal timescales through competitive interactions. Comparison among two forest dynamics plots suggests that forest structural diversity responds to intermediate-scale environmental heterogeneity and disturbances, similar to hypotheses about patterns of species richness, and richness- ecosystem function. Large mapped plots with detailed within-plot environmental spatial covariates will be required to test these hypotheses.

  2. Relationship between lumen diameter and length sterilized in the 125L ozone sterilizer.

    Science.gov (United States)

    Dufresne, Sylvie; Leblond, Hélène; Chaunet, Marc

    2008-05-01

    A safe alternative to ethylene oxide for reprocessing heat-sensitive lumen medical devices, such as endoscopes, is needed. The effectiveness of a new, safe, low-cost, and environmentally friendly low-temperature sterilization process using ozone was assessed. Rigid lumen devices were used to assess the maximum length of lumens of different internal diameters that can be sterilized in the TSO(3) model 125L ozone sterilizer. Two inoculation techniques were used. An inoculated wire was placed inside lumens with internal diameters of 0.8 mm and larger, whereas lumens with an internal diameter of 0.5 mm were inoculated directly. Lumens with internal diameters of 0.5 mm, 1 mm, 2 mm, 3 mm, and 4 mm with lengths varying between 45 and 70 cm can be sterilized with ozone. Calculation of the log reduction value for each size demonstrated the achievement of a sterility assurance level of 10(-6). Experimental results demonstrated a linear relationship (with r(2) = 0.990) between the length of lumen that can be sterilized in the 125L ozone sterilizer and its internal diameter. Effective sterilization of an ACMI ureteroscope that is more challenging in terms of sterilant penetration in a small lumen (0.8 mm) compared with the stated lumen claims confirms that the relationship can conservatively be used to predict the length of a lumen device that can be sterilized in the 125L ozone sterilizer for a given diameter. Intermediate sizes of lumen devices that can be sterilized in the 125L ozone sterilizer can be interpolated from the linear relationship between diameter and length found in the present study.

  3. Influence of focal spot on characteristics of very small diameter radiosurgical beams.

    Science.gov (United States)

    Sham, Edwin; Seuntjens, Jan; Devic, Slobodan; Podgorsak, Ervin B

    2008-07-01

    Percentage depth dose (PDD) distributions and beam profiles of very small diameter (1.5-5 mm) megavoltage radiosurgical beams calculated with Monte Carlo (MC) technique critically depend on the diameter of the circular focal spot used in the simulation: The smaller is the field diameter, the larger is the effect. Thus, in simulations of radiosurgical fields that have diameters of the order of the focal spot size, an accurate focal spot geometry should be used. We used a simplified moving slit technique in conjunction with a diode detector for evaluation of the focal spot size and shape of a megavoltage 6 MV linac as well as for determination of the equivalent focal spot diameter of the linac for use in MC simulations. The measured total diode signal contains three components: A direct focal spot signal, a background signal, and an extra-focal radiation signal. A single profile scan of the focal spot signal is Gaussian like in shape, and its full width at half maximum is used to define the focal spot dimension for this scan. The focal spot of our 6 MV linac is approximated with a Gaussian circle, and when the geometry of the effective focal spot circle is used in MC simulations, the agreement between MC-calculated and measured PDD distributions as well as beam profiles is good even for radiosurgical fields as small as 1.5 mm in diameter. Our results also confirm that matching the penumbral areas of accurately measured large-field beam profiles to the same areas of the MC-calculated beam profiles reliably leads to a realistic effective focal spot size for use in MC simulations of very small diameter beams.

  4. Effect of needle insertion depth and apical diameter on irrigant extrusion in simulated immature permanent teeth

    Directory of Open Access Journals (Sweden)

    AKSEL Hacer

    2014-09-01

    Full Text Available The aim of this study was to compare the amount of irrigant extrusion in simulated immature permanent teeth when the apical diameter and needle insertion depth were varied. Thirty single-rooted maxillary incisors with straight root canals were selected. The root length was standardized to a length of 9 mm. The teeth were divided into two experimental groups according to the degree of apical enlargement (n = 15. The apices were enlarged to a diameter of 1.10 mm or 1.70 mm by using a #3 or #6 peeso reamer, respectively, to simulate immature teeth. The irrigation solution was applied 2 or 4 mm short of the working length (WL in each experimental group. The glass vial model was used for the collection of extruded irrigant beyond the root apex. A two-way repeated measures analysis of variance test showed that there was no significant difference between different needle insertion depths (2 and 4 mm short of the WL in the group with an apical diameter of 1.70 mm (p > 0.05. In the group with an apical diameter of 1.10 mm, a 32% increase in irrigant extrusion was observed when the needle was positioned at 2 mm (p < 0.05. Regarding the effect of apical diameter, the group with a diameter of 1.70 mm showed more apical extrusion of the irrigant (34% increase for the needle positioned at 2 mm and 68% increase for the needle positioned at 4 mm. It was observed that the needle insertion depth and apical diameter have a significant effect on irrigant extrusion in immature permanent teeth.

  5. Tannins gravimetric yield condensed in Anadenanthera peregrina bark in different diameter classes

    Directory of Open Access Journals (Sweden)

    Caroline Junqueira Sartori

    2014-06-01

    Full Text Available This work aimed to determine the gravimetric yield of condensed tannins in the Anadenanthera peregrina bark in different diameter classes. Fifty-nine trees samples were collected of Anadenanthera peregrina, at 1.30m of the ground (diameter at breast height - DBH, distributed in seven diameter classes. The barks were dried and crushed in mill of hammer. Composite sample was made to prepare the extract. The extraction was done using water in the ratio 15:1 (v/w, added 3% sodium sulfite (w/w in water-bath at 70°C for 4 hours. The material was filtered using fine cloth strainer and concentrated on a heating plate at approximately 150 g. It was determined the extract mass and removed 10 g for obtaining solids content and 20g for the Stiasny's index. The average values of total solids content, Stiasny's index, condensed tannin content and the compound content non-tannin were 11.34%; 75.79%; 12.76% and 4.07%, respectively. The content of solids, Stiasny's index, compound content non-tannin show significant differences between diameter classes. For the condensed tannins production, the diameter class parameter there was no influence.

  6. An Improved Weise’s Rule for Efficient Estimation of Stand Quadratic Mean Diameter

    Directory of Open Access Journals (Sweden)

    Róbert Sedmák

    2015-07-01

    Full Text Available The main objective of this study was to explore the accuracy of Weise’s rule of thumb applied to an estimation of the quadratic mean diameter of a forest stand. Virtual stands of European beech (Fagus sylvatica L. across a range of structure types were stochastically generated and random sampling was simulated. We compared the bias and accuracy of stand quadratic mean diameter estimates, employing different ranks of measured stems from a set of the 10 trees nearest to the sampling point. We proposed several modifications of the original Weise’s rule based on the measurement and averaging of two different ranks centered to a target rank. In accordance with the original formulation of the empirical rule, we recommend the application of the measurement of the 6th stem in rank corresponding to the 55% sample percentile of diameter distribution, irrespective of mean diameter size and degree of diameter dispersion. The study also revealed that the application of appropriate two-measurement modifications of Weise’s method, the 4th and 8th ranks or 3rd and 9th ranks averaged to the 6th central rank, should be preferred over the classic one-measurement estimation. The modified versions are characterised by an improved accuracy (about 25% without statistically significant bias and measurement costs comparable to the classic Weise method.

  7. Axial variation of basic density of Araucaria angustifolia wood in different diameter classes

    Directory of Open Access Journals (Sweden)

    Rômulo Trevisan

    Full Text Available ABSTRACT: The study of the wood characteristics is of fundamental importance for the correct use of this raw material and, among its properties, the basic density is a major, being reference in the quality of this material. This study aimed to evaluate the axial variation of basic density of the wood of Araucaria angustifolia (Bertoloni O. Kuntze in different diameter classes. For this, three trees were selected in six diameter classes, called class 1 (20-30cm, class 2 (30.1-40cm, class 3 (40.1-50cm, class 4 (50.1-60cm, class 5 (60.1-70cm and class 6 (70.1-80cm. From each individual sampled was withdrawn a disc at 0.1m (base, 25, 50, 75 and 100% of the height of the first live branch and in the diameter at 1.30m from the ground (DBH, which were used for determining basic density. The weighted average basic density was equal to 0.422g cm-3 and, regardless of the diameter class analyzed, this property decreased in the axial direction. Diameter induced variation of basic density, but has not been verified a positive or negative systematic tendency in relation to the sampled interval.

  8. Pupil Diameter Does Not Correlate with Fixation Duration - or Does It?

    DEFF Research Database (Denmark)

    Lykke Jakobsen, Arnt; Carl, Michael; Elming, Jakob

    2013-01-01

    A number of pupillometric studies have suggested that dynamic differences in pupil diameter correlate with dierent levels of cognitive intensity or excitement. Other studies have suggested a similar correlation between fixation duration and cognitive effort. Since both methodologies for hypothesi......A number of pupillometric studies have suggested that dynamic differences in pupil diameter correlate with dierent levels of cognitive intensity or excitement. Other studies have suggested a similar correlation between fixation duration and cognitive effort. Since both methodologies...... for hypothesizing about cognitive effort are contested, we examined if the two measures co-vary in eye-tracked observations of translators while performing a translation or text-revision task. A plot representation of pupil diameter measurements inserted in a progression graph showing a participant's gaze path...... microbehavioural methodologies, the most interesting result was establishing whether or not the pupil diameter of translators and revisers co-varies systematically with fixation duration, such that the occurrence of larger-than-average pupil diameters correlates with longer-than-average fixations, regardless...

  9. The effect of nozzle-exit-channel shape on resultant fiber diameter in melt-electrospinning

    Science.gov (United States)

    Esmaeilirad, Ahmad; Ko, Junghyuk; Rukosuyev, Maxym V.; Lee, Jason K.; Lee, Patrick C.; Jun, Martin B. G.

    2017-01-01

    In recent decades, electrospinning using a molten poly (ε-caprolactone) resin has gained attention for creating fibrous tissue scaffolds. The topography and diameter control of such electrospun microfibers is an important issue for their different applications in tissue engineering. Charge density, initial nozzle-exit-channel cross-sectional area, nozzle to collector distance, viscosity, and processing temperature are the most important input parameters that affect the final electrospun fiber diameters. In this paper we will show that the effect of nozzle-exit-channel shape is as important as the other effective parameters in a resultant fiber diameter. However, to the best of our knowledge, the effect of nozzle-exit-channel shapes on a resultant fiber diameter have not been studied before. Comparing rectangular and circular nozzles with almost the same exit-channel cross-sectional areas in a similar processing condition showed that using a rectangular nozzle resulted in decreasing final fiber diameter up to 50%. Furthermore, the effect of processing temperature on the final fiber topography was investigated.

  10. Effect of Catalytic Layer Thickness on Diameter of Vertically Aligned Individual Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Hyun Kyung Jung

    2014-01-01

    Full Text Available The effect of catalytic thin film thickness on the diameter control of individual carbon nanotubes grown by plasma enhanced chemical vapor deposition was investigated. Individual carbon nanotubes were grown on catalytic nanodot arrays, which were fabricated by e-beam lithography and e-beam evaporation. During e-beam evaporation of the nanodot pattern, more catalytic metal was deposited at the edge of the nanodots than the desired catalyst thickness. Because of this phenomenon, carbon atoms diffused faster near the center of the dots than at the edge of the dots. The carbon atoms, which were gathered at the interface between the catalytic nanodot and the diffusion barrier, accumulated near the center of the dot and lifted the catalyst off. From the experiments, an individual carbon nanotube with the same diameter as that of the catalytic nanodot was obtained from a 5 nm thick catalytic nanodot; however, an individual carbon nanotube with a smaller diameter (~40% reduction was obtained from a 50 nm thick nanodot. We found that the thicker the catalytic layer, the greater the reduction in diameter of the carbon nanotubes. The diameter-controlled carbon nanotubes could have applications in bio- and nanomaterial scanning and as a contrast medium for magnetic resonance imaging.

  11. A STUDY ON DIAMETER OF PERFORATORS AND CLINICAL SEVERITY OF CHRONIC VENOUS INSUFFICIENCY

    Directory of Open Access Journals (Sweden)

    Visakh

    2015-10-01

    Full Text Available BACKGROUND : Perforator incompetence is an important part of assessment of chronic venous insufficiency ( CVI, but the criteria for perforator incompetence and the relationship with clinical severity is not well established. AIM: To study whether measurement of diameter of perforator correlates with clinical severity of venous insufficiency. MATERIALS AND METHODS: One hundred and forty five consecutive patients ( 168 limbs with varicose veins were evaluated with Doppler study of lower limb veins. Clinical severity and diameter of perforators were assessed. RESULTS: 23% of patients with clinically mild disease had perforator diameter of 3mm or more , whereas , 62% of moderate and severe disease patients had incompetent perforator. Average diameter of perforator in CVI class 1 & 2 patients was 1.44mm whereas , in class 3 & 4 patients , it was 3.31mm and 3.58mm in class 5 & 6 patients. CONCLUSION : Diameter of perforator compare favourably with clinical severity of chronic venous insufficiency. This study may help to evolve patient management guidelines in perforator incompetence treatment

  12. PHOS Experiment: Thermal Response of a Large Diameter Pulsating Heat Pipe on Board REXUS-18 Rocket

    Science.gov (United States)

    Creatini, F.; Guidi, G. M.; Belfi, F.; Cicero, G.; Fioriti, D.; Di Prizio, D.; Piacquadio, S.; Becatti, G.; Orlandini, G.; Frigerio, A.; Fontanesi, S.; Nannipieri, P.; Rognini, M.; Morganti, N.; Filippeschi, S.; Di Marco, P.; Fanucci, L.; Baronti, F.; Mameli, M.; Marengo, M.; Manzoni, M.

    2015-09-01

    In the present work, the results of two Closed Loop Pulsating Heat Pipes (CLPHPs) tested on board REXUS-1 8 sounding rocket in order to get experimental data over a relatively broad reduced gravity period (about 90 s) are thoroughly discussed. The CLPHPs are partially filled with refrigerant FC-72 and have, respectively, an inner tube diameter larger (3 .0 mm) and slightly smaller (1 .6 mm) than a critical diameter defined on Earth gravity conditions. On ground, the small diameter CLPHP works as a real Pulsating Heat Pipe (PHP): the typical capillary slug flow pattern forms inside the device and the heat exchange is triggered by self-sustained thermally driven oscillations of the working fluid. Conversely, the large diameter CLPHP behaves like a two-phase thermosyphon in vertical position while does not operate in horizontal position as the working fluid stratifies within the tube and surface tension is not able to balance buoyancy. Then, the idea to test the CLPHPs under reduced gravity conditions: as soon as gravity reduces, buoyancy becomes less intense and the typical capillary slug flow pattern can also forms within a tube with a larger diameter. Moreover, this allows to increase the heat transfer rate and, consequently, to decrease the overall thermal resistance. Even though it was not possible to experience the expected reduced gravity conditions due to a failure of the yo-yo de-spin system, the thermal response to the peculiar acceleration field (hyper-gravity) experienced on board are thoroughly described.

  13. Diameter limitation in growth of III-Sb-containing nanowire heterostructures.

    Science.gov (United States)

    Ek, Martin; Borg, B Mattias; Johansson, Jonas; Dick, Kimberly A

    2013-04-23

    The nanowire geometry offers significant advantages for exploiting the potential of III-Sb materials. Strain due to lattice mismatch is efficiently accommodated, and carrier confinement effects can be utilized in tunneling and quantum devices for which the III-Sb materials are of particular interest. It has however proven difficult to grow thin (below a few tens of nanometers), epitaxial III-Sb nanowires, as commonly no growth is observed below some critical diameter. Here we explore the processes limiting the diameter of III-Sb nanowires in a model system, in order to develop procedures to control this effect. The InAs-GaSb heterostructure system was chosen due to its great potential for tunneling devices in future low-power electronics. We find that with increasing growth temperature or precursor partial pressures, the critical diameter for GaSb growth on InAs decreases. To explain this trend we propose a model where the Gibbs-Thomson effect limits the Sb supersaturation in the catalyst particle. This understanding enabled us to further reduce the nanowire diameter down to 32 nm for GaSb grown on 21 nm InAs stems. Finally, we show that growth conditions must be carefully optimized for these small diameters, since radial growth increases for increased precursor partial pressures beyond the critical values required for nucleation.

  14. Effect of Orifice Diameter on Bubble Generation Process in Melt Gas Injection to Prepare Aluminum Foams

    Science.gov (United States)

    Yuan, Jianyu; Li, Yanxiang; Wang, Ningzhen; Cheng, Ying; Chen, Xiang

    2016-06-01

    The bubble generation process in conditioned A356 alloy melt through submerged spiry orifices with a wide diameter range (from 0.07 to 1.0 mm) is investigated in order to prepare aluminum foams with fine pores. The gas flow rate and chamber pressure relationship for each orifice is first determined when blowing gas in atmospheric environment. The effects of chamber pressure ( P c) and orifice diameter ( D o) on bubble size are then analyzed separately when blowing gas in melt. A three-dimensional fitting curve is obtained illustrating both the influences of orifice diameter and chamber pressure on bubble size based on the experimental data. It is found that the bubble size has a V-shaped relationship with orifice diameter and chamber pressure neighboring the optimized parameter ( D o = 0.25 mm, P c = 0.4 MPa). The bubble generation mechanism is proposed based on the Rayleigh-Plesset equation. It is found that the bubbles will not be generated until a threshold pressure difference is reached. The threshold pressure difference is dependent on the orifice diameter, which determines the time span of pre-formation stage and bubble growth stage.

  15. Atomic layer deposition as pore diameter adjustment tool for nanoporous aluminum oxide injection molding masks.

    Science.gov (United States)

    Miikkulainen, Ville; Rasilainen, Tiina; Puukilainen, Esa; Suvanto, Mika; Pakkanen, Tapani A

    2008-05-06

    The wetting properties of polypropylene (PP) surfaces were modified by adjusting the dimensions of the surface nanostructure. The nanostructures were generated by injection molding with nanoporous anodized aluminum oxide (AAO) as the mold insert. Atomic layer deposition (ALD) of molybdenum nitride film was used to control the pore diameters of the AAO inserts. The original 50-nm pore diameter of AAO was adjusted by depositing films of thickness 5, 10, and 15 nm on AAO. Bis(tert-butylimido)-bis(dimethylamido)molybdenum and ammonia were used as precursors in deposition. The resulting pore diameters in the nitride-coated AAO inserts were 40, 30, and 20 nm, respectively. Injection molding of PP was conducted with the coated inserts, as well as with the non-coated insert. Besides the pore diameter, the injection mold temperature was varied with temperatures of 50, 70, and 90 degrees C tested. Water contact angles of PP casts were measured and compared with theoretical contact angles calculated from Wenzel and Cassie-Baxter theories. The highest contact angle, 140 degrees , was observed for PP molded with the AAO mold insert with 30-nm pore diameter. The Cassie-Baxter theory showed better fit than the Wenzel theory to the experimental values. With the optimal AAO mask, the nanofeatures in the molded PP pieces were 100 nm high. In explanation of this finding, it is suggested that some sticking and stretching of the nanofeatures occurs during the molding. Increase in the mold temperature increased the contact angle.

  16. An Experimental and Numerical Study on Embedded Rebar Diameter in Concrete Using Ground Penetrating Radar

    Directory of Open Access Journals (Sweden)

    Md Istiaque Hasan

    2016-01-01

    Full Text Available High frequency ground penetrating radar (GPR has been widely used to detect and locate rebars in concrete. In this paper, a method of estimating the diameter of steel rebars in concrete with GPR is investigated. The relationship between the maximum normalized positive GPR amplitude from embedded rebars and the rebar diameter was established. Concrete samples with rebars of different diameters were cast and the maximum normalized amplitudes were recorded using a 2.6 GHz GPR antenna. Numerical models using GPRMAX software were developed and verified with the experimental data. The numerical models were then used to investigate the effect of dielectric constant of concrete and concrete cover on the maximum normalized amplitude. The results showed that there is an approximate linear relationship between the rebar diameter and the maximum GPR normalized amplitude. The developed models can be conveniently used to estimate the embedded rebar diameters in existing concrete with GPR scanning; if the concrete is homogeneous, the cover depth is known and the concrete dielectric constant is also known. The models will be highly beneficial in forensic investigations of existing concrete structures with unknown rebar sizes and locations.

  17. A theoretical investigation of low frequency diameter oscillations of muscular arteries.

    Science.gov (United States)

    Achakri, H; Rachev, A; Stergiopulos, N; Meister, J J

    1994-01-01

    Spontaneous low frequency diameter oscillations have been observed in vivo in some muscular arteries. The aim of this paper is to propose a possible mechanism for their appearance. A lumped parameter mathematical model for the mechanical response of an artery perfused with constant flow is proposed, which takes into account the active behavior of the vascular smooth muscle. The system of governing equations is reduced into two nonlinear autonomous differential equations for the arterial circumferential stretch ratio, and the concentration of calcium ions, Ca2+, within the smooth muscle cells. Factors controlling the muscular tone are taken into account by assuming that the rate of change of Ca2+ depends on arterial pressure and on shear stress acting on the endothelium. Using the theory of dynamical systems, it was found that the stationary solution of the set of governing equations may become unstable and a periodic solution arises, yielding self-sustained diameter oscillations. It is found that a necessary condition for the appearance of diameter oscillations is the existence of a negative slope of the steady state pressure-diameter relationship, a phenomenon known to exist in arterioles. A numerical parametric study was performed and bifurcation diagrams were obtained for a typical muscular artery. Results show that low frequency diameter oscillations develop when the magnitude of the perfused inflow, the distal resistance, as well as the length of the artery are within a range of critical values.

  18. Tailoring the diameter and density of self-catalyzed GaAs nanowires on silicon

    Science.gov (United States)

    Matteini, Federico; Dubrovskii, Vladimir G.; Rüffer, Daniel; Tütüncüoğlu, Gözde; Fontana, Yannik; Morral, Anna Fontcuberta I.

    2015-03-01

    Nanowire diameter has a dramatic effect on the absorption cross-section in the optical domain. The maximum absorption is reached for ideal nanowire morphology within a solar cell device. As a consequence, understanding how to tailor the nanowire diameter and density is extremely important for high-efficient nanowire-based solar cells. In this work, we investigate mastering the diameter and density of self-catalyzed GaAs nanowires on Si(111) substrates by growth conditions using the self-assembly of Ga droplets. We introduce a new paradigm of the characteristic nucleation time controlled by group III flux and temperature that determine diameter and length distributions of GaAs nanowires. This insight into the growth mechanism is then used to grow nanowire forests with a completely tailored diameter-density distribution. We also show how the reflectivity of nanowire arrays can be minimized in this way. In general, this work opens new possibilities for the cost-effective and controlled fabrication of the ensembles of self-catalyzed III-V nanowires for different applications, in particular in next-generation photovoltaic devices.

  19. EFFECT OF SUCTION PIPE DIAMETER AND SUBMERGENCE RATIO ON AIR LIFT PUMPING RATE

    Directory of Open Access Journals (Sweden)

    Salam J. AlMaliky

    2013-05-01

    Full Text Available The increasingly importance for the uses of the air lift pump in widespread list of fields (mining, nuclear industries, agricultural uses, petroleum industries...etc. makes it very interested for the researchers to find tools to raise the performance outcome of such pumps.An air lift pump system is setup to study the effect of the suction pipe diameter and submergence ratio on the liquid (water pumping rate. The system has a lift pipe of (0.021 m diameter and (1.25 m length. Five diameters for the suction pipe (0.021, 0.027, 0.033, 0.048 and 0.063 m with  a fixed length of (0.3 m, are tested for each of the submergence ratios (0.2, 0.3, 0.4, 0.5 respectively.        Results indicate that the higher the diameter of suction pipe is the higher the pumping rate for a fixed submergence ratio. From another side, the higher the submergence ratio is the higher the pumping rate for a fixed suction pipe diameter. Also, under high submergence ratios, high pumping rates are achieved by the use of lower air flow rates compared with those used with lower submergence ratios. The experimental results show good compatibility with the model suggested by Stenning and Martin for the performance of an air lift pump.

  20. Single-walled carbon nanotubes of controlled diameter and bundle size and their field emission properties.

    Science.gov (United States)

    Zhang, Liang; Balzano, Leandro; Resasco, Daniel E

    2005-08-04

    Field emission studies were conducted on as-produced CoMoCAT single-walled carbon nanotube/silica composites with controlled nanotube diameter and bundle size. It has been observed that the as-produced nanotube material does not need to be separated from the high-surface area catalyst to be an effective electron emitter. By adjusting the catalytic synthesis conditions, single-walled carbon nanotubes (SWNT) of different diameters and bundle sizes were synthesized. A detailed characterization involving Raman spectroscopy, optical absorption (vis-NIR), SEM, and TEM was conducted to identify the nanotube species present in the different samples. The synthesis reaction temperature was found to affect the nanotube diameter and bundle size in opposite ways; that is, as the synthesis temperature increased the nanotube average diameter became larger, but the bundle size became smaller. A gradual and consistent reduction in the emission onset field was observed as the synthesis temperature increased. It is suggested that the bundle size, more than the nanotube diameter or chirality, determines the field emission characteristics of these composites. This is a clear demonstration that field emission characteristics of SWNT can be controlled by the nanotube synthesis conditions.

  1. High-speed high-resolution fine wire diameter measurement system

    Science.gov (United States)

    Guimaraes, Marcelo F.; Doiron, Theodore D.

    1993-10-01

    A fine wire diameter measurement system, for on-line monitoring, has been proposed by using a Machine Vision System and a visible diode laser. The system uses the Fraunhofer diffraction principle. The diffraction pattern, generated by a small wire exposed to a collimated laser beam, is acquired by a CCD industrial camera that is connected to a processing board inside a PC computer. Two different methods of measuring the diameters, static and dynamic, have been proposed in order to get high precision and high measurement rate. Wires with diameter from 10 to 350 micrometers have been measured by this system with 0.06% resolution. The accuracy is less than +/- 0.5% over a range of 90 - 350 micrometers diameter. For thinner wires, the measurement system should be calibrated to eliminate the systematic errors. The estimate random errors are +/- 0.25%. The instrument can measure the wire diameter at a 1000 Hz rate and allows it to move laterally in a 1 mm square window, maintaining the above accuracy. The system is compact and there are no moving parts.

  2. Can outer-to-outer diameter be used alone in diagnosing appendicitis on 128-slice MDCT?

    Institute of Scientific and Technical Information of China (English)

    Jamal; Yaqoob; Muhammad; Idris; Muhammad; Shahbaz; Alam; Nazia; Kashif

    2014-01-01

    AIM: To assess the frequency of visualization, position and diameter of normal appendix on 128-slice multidetector computed tomography(MDCT) in adult population.METHODS: Retrospective cross sectional study conducted at Radiology Department, Dallah Hospital, Riyadh, Saudi Arabia from March 2013 to October 2013. Non-enhanced computed tomography scans of abdomen and pelvis of 98 patients presenting with hematuria(not associated with abdominal pain, fever or colonic disease) were reviewed by two radiologists, blinded to patient history. The study group included 55 females and 43 males with overall mean age of 54.7 years(range 21 to 94 years). The coronal reformatted images were reviewed in addition to the axial images. The frequency of visualization of appendix was recorded with assessment of position, diameter and luminal contents.RESULTS: The appendix was recorded as definitely visualized in 99% of patients and mean outer-to-outer diameter of the appendix was 5.6 ± 1.3 mm(range 3.0-11.0 mm).CONCLUSION: MDCT with its multiplanar reformation display is extremely useful for visualization of normal appendix. The normal appendix is very variable in its position and diameter. In the absence of other signs, the diagnosis of acute appendix should not be made solely on outer-to-outer appendiceal diameter.

  3. A Fast Measuring Method for the Inner Diameter of Coaxial Holes

    Science.gov (United States)

    Wang, Lei; Yang, Fangyun; Fu, Luhua; Wang, Zhong; Yang, Tongyu; Liu, Changjie

    2017-01-01

    A new method for fast diameter measurement of coaxial holes is studied. The paper describes a multi-layer measuring rod that installs a single laser displacement sensor (LDS) on each layer. This method is easy to implement by rotating the measuring rod, and immune from detecting the measuring rod’s rotation angles, so all diameters of coaxial holes can be calculated by sensors’ values. While revolving, the changing angles of each sensor’s laser beams are approximately equal in the rod’s radial direction so that the over-determined nonlinear equations of multi-layer holes for fitting circles can be established. The mathematical model of the measuring rod is established, all parameters that affect the accuracy of measurement are analyzed and simulated. In the experiment, the validity of the method is verified, the inner diameter measuring precision of 28 μm is achieved by 20 μm linearity LDS. The measuring rod has advantages of convenient operation and easy manufacture, according to the actual diameters of coaxial holes, and also the varying number of holes, LDS’s mounting location can be adjusted for different parts. It is convenient for rapid diameter measurement in industrial use. PMID:28327499

  4. Coefficient of variation of nuclear diameters as a prognostic factor in papillary thyroid carcinoma.

    Science.gov (United States)

    Chang, T C; Kuo, S H; How, S W

    1991-12-01

    To determine whether the coefficient of variation (CV) of nuclear diameters can be used as a prognostic factor in papillary thyroid carcinoma, we reviewed fine needle aspiration smears with Riu's stain from 55 operated-on and pathologically verified cases with a median follow-up of 6.5 years. For each case we measured the nuclear diameters of 100 cancer cells by ocular micrometry and calculated the CV of the nuclear diameters. Then we correlated the CV with the clinical stage, recurrence and death. There was a positive correlation between the CV of the nuclear diameters and the clinical stage (r = .59, P less than .0001). Recurrent cases (n = 10) had a higher CV than did those without recurrence (n = 45) (18.04 +/- 4.1% [mean +/- SD] versus 13.2 +/- 2.7%, P less than .0005). All recurrent cases had a CV greater than 13%. The cases in which death occurred (n = 5) had a higher CV than did those with survival (n = 50) (20.1 +/- 4.9% versus 13.5 +/- 2.7%, P less than .0005). All cases in which death occurred had a CV greater than 15%. The extent of variation of nuclear diameters was one of the factors influencing prognosis in papillary thyroid carcinoma. It offers a prognostic adjunct to standard clinical and histologic analysis.

  5. Electroless reductions on carbon nanotubes: How critical is the diameter of a nanotube

    KAUST Repository

    Guo, Yong

    2013-01-01

    Detailed experimental and theoretical studies have been performed to investigate the influence of the diameter of multi-walled carboxy-functionalized carbon nanotubes (CFCNTs) on their ability to reduce PdCl4 2- salt to Pd nanoparticles on their surface at room temperature. The obtained results (inductively-coupled plasmaspectrometry and cyclic voltammetry) show that the reduction ability of CFCNTs with 5 nm diameter (CFCNT5) is stronger than that of CFCNTs with 15 nm diameter (CFCNT15). Density Functional Theory (DFT) calculations suggest that a more negative charge distribution exists on CFCNT5, which makes it a better electron donor to PdCl42-. This journal is © The Royal Society of Chemistry.

  6. Centrifuge modelling of large diameter pile in sand subject to lateral loading

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane

    Large-diameter (4 to 6 m) rigid monopiles are often used as foundations for offshore wind turbines. The monopiles are subjected to large horizontal forces and overturning moments and they are traditionally designed based on the p-y curve method. The p-y curves recommended in offshore design...... and cyclic behaviour of large diameter rigid piles in dry sand by use of physical modelling. The physical modelling has been carried out at Department of Civil Engineering at the Danish Technical University (DTU.BYG), in the period from 2005 to 2009. The main centrifuge facilities, and especially...... the equipment for lateral load tests were at the start of the research in 2005 outdated and a major part of the work with the geotechnical centrifuge included renovation and upgrading of the facilities. The research with respect to testing of large diameter piles included:  Construction of equipment...

  7. Stability analysis of large diameter thin-walled tube beam-columns

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Based on a blind spot in the current design standard of steel structures,the large diameter thin-walled tube beam-columns are analyzed using nonlinear finite element method in this paper.The influence of several factors on stability capacity of the large diameter thinwalled tube beam-columns is taken into account.Thus,according to the correlative design standard of steel structures,and on the basis of the numerical analytical results by the finite element methods,the calculation formulas of the stability bearing capacity are presented for beam-column members of the large diameter thin-walled tubes.Three tests of thin-walled steel tube beam-columns were reported.Test results for deformations and ultimate strength are found to be in a good agreement with the corresponding values predicted by the calculation formulas,and the proposed methods can be used in design practice.

  8. Numerical Modelling of Large-Diameter Steel Piles at Horns Rev

    DEFF Research Database (Denmark)

    Augustesen, Anders Hust; Brødbæk, K. T.; Møller, M.;

    2009-01-01

    Today large-diameter monopiles are the most common foundation type used for large offshore wind farms. This paper aims to investigate the behaviour of monopiles under monotonic loading taking the interaction between the pile and the subsoil into account. Focus is paid to a monopile used as founda......Today large-diameter monopiles are the most common foundation type used for large offshore wind farms. This paper aims to investigate the behaviour of monopiles under monotonic loading taking the interaction between the pile and the subsoil into account. Focus is paid to a monopile used...... as foundation for a wind turbine at Horns Rev located in the Danish sector of the North Sea. The outer diameter of the pile is 4 m and the subsoil at the location consists primarily of sand. The behaviour of the pile is investigated under realistic loading conditions by means of a traditional Winkler...

  9. Skin Blood Perfusion and Cellular Response to Insertion of Insulin Pen Needles With Different Diameters

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente Merete; Bo Jensen, Casper

    2014-01-01

    Today most research on pen needle design revolves around pain perception statements through clinical trials, but these are both costly, timely, and require high sample sizes. The purpose of this study was to test if tissue damage, caused by different types of needles, can be assessed by evaluating...... skin blood perfusion response around needle insertion sites. Three common sized pen needles of 28G, 30G, and 32G as well as hooked 32G needles, were inserted into the neck skin of pigs and then removed. Laser Speckle Contrast Analysis was used to measure skin blood perfusion for 20 minutes after......, but there was a trend of an increased response with increasing needle diameter. Skin blood perfusion response to pen needle insertions rank according to needle diameter, and the tissue response caused by hooked 32G needles corresponds to that of 28G needles. The relation between needle diameter and trauma when...

  10. Effects of solution properties on the morphology and diameters of nanofibers fabricated by electrospinning

    Science.gov (United States)

    Jing, Hongjun; Jiang, Yadong; Du, Xiaosong

    2010-10-01

    In this paper, four different series of polymer solutions were presented to study the effects of solution properties on the morphology and diameters of nanofibers, including the polyethersulfone (PES) dissolving in N, N-dimethylformamide, polyvinylpyrrolidone (PVP) in ethanol, poly(acrylic acid) (PAA) in water and poly(vinylidene fluoride) (PVDF) in N, Ndimethyl acetamide. These solutions revealed different conditions of the formation of beads, the spatial structures and the diameter of fibers. The PVDF nanofibers had plenty of small beads on the fibers, while the other three were uniform fibers without beads. The nanofibers of PES, PVP and PVDF showed good three dimensional structures except the PAA fibrous membranes. The change of fiber diameters of PVDF was much larger than that of PVP.

  11. Biomass Estimation of Individual Trees Using STEM and Crown Diameter Tls Measurements

    Science.gov (United States)

    Holopainen, M.; Vastaranta, M.; Kankare, V.; Räty, M.; Vaaja, M.; Liang, X.; Yu, X.; Hyyppä, J.; Hyyppä, H.; Viitala, R.; Kaasalainen, S.

    2011-09-01

    The objective of this study was to make preliminary investigations between accurately measured field biomasses and terrestrial laser scanning (TLS) measurements including tree crown and stem diameters. Stem and crown biomass were determined based on detailed field measurements of the individual tree stem, bark, branch and needles. At the tree level, field measurements were intensive and thus material consisted of only 20 trees located at 11 stands. Stem and crown diameters were extracted manually from TLS point clouds and used as predictors for total biomass. Correlations from 0.96 to 0.99 between predicted and field measured biomass estimates were obtained. Examination of stem form predictions showed that various diameters measured by TLS could enhance the tree level stem curve predictions. Results are rather promising, but more field data is needed for developing practical modelling means. Our further studies will concentrate on automation of TLS data processing and use the of TLS features in the biomass estimation.

  12. Is it possible to measure diameters of metal nanoparticles using BSE imaging in FESEM?

    Science.gov (United States)

    Nebesarova, Jana; Langhans, Jan; Slouf, Miroslav; Pavlova, Ewa; Vancova, Marie

    2013-01-01

    The possibilities of using a field emission scanning electron microscope (FESEM) equipped with an Autrata improved yttrium aluminum garnet (YAG) detector of back-scattered electrons (BSE) for a determination of metal nanoparticles sizes were examined in this study. The diameters of Au and Pd nanoparticles with different sizes were resolved based on digitally recorded FESEM micrographs and were compared with diameters obtained with a transmission electron microscope (TEM). In the case of Au nanoparticles, the data obtained from the FESEM exhibited smaller values in comparison with data from the TEM. The Pd nanoparticles diameters measured in the FESEM were comparable with those determined by means of the TEM, however. The influence of various parameters like the sizes of nanoparticles, their composition, use of accelerating voltage and other working conditions in the FESEM on the measurement results are discussed.

  13. Effect of climate index on diameter increment of 40 Austrian pine half-sib lines

    Directory of Open Access Journals (Sweden)

    Vukin Marina

    2006-01-01

    Full Text Available The effects of the climate characters and climate index calculated by Thornthwaite-Mather method on diameter increment of Austrian pine trees in the seedling seed orchard on Jelova Gora was studied in the period from 1996 to 2002. The samples for dendrometric analysis were taken from 498 trees in 40 half-sib lines originating from the best natural sites of this species. A strong correlation was determined between the range of precipitation regime and Thornthwaite-Mather climate index, and the development of current diameter increment. The study results indicate that the diameter increment of Austrian pine increases considerably with the increase of humidity, regardless of the relatively modest demands regarding the site productive characteristics.

  14. NON DESTRUCTIVE EVALUATION OF HEARTWOOD DIAMETER AT BREAST HEIGHT FOR EUCALYPTUS GLOBULUS AND POPULUS EURAMERICANA HYBRID

    Directory of Open Access Journals (Sweden)

    Hugo Alexandre Jóia

    2006-12-01

    Full Text Available The objective of this study was the evaluation of the heartwood diameter (dcerne at breast height on stand trees, for Eucalyptus globulus Labill and the hybrid Populus euramericana. The data used was collected in eucalyptus and popular pure plantations in Central and North Portugal.The non destructive methods tested in the evaluation of heartwood diameter at breast height were [1] visual identification of the heartwood on core samples and [2] indirect estimation using mathematic models. The results allow to consider that visual determination of dcerne is appropriate for Populus, and development of prediction models based diameter at breast height (d, total height (h and age (t, give better results for eucalyptus.

  15. Stress Wave Dispersion in Large-Diameter SHPB and Its Manifold Manifestations

    Institute of Scientific and Technical Information of China (English)

    王永刚; 王礼立

    2004-01-01

    The wave dispersion due to the lateral inertia in the split Hopkinson pressure bar(SHPB) with large-diameter bar is numerically analyzed by means of the LS-DYNA3D code. The results show that, ① the stress distribution across the bar section is non-uniform along the radius direction and such non-uniformity depends on the material Poisson ratio and propagation distance; ② with increasing the bar diameter, the high frequency oscillations are notably enhanced and the rise time of wave front becomes longer, meanwhile the amplitude of the stress wave attenuates; ③ with decreasing the rise time of wave front, the wave dispersion markedly enhanced, particularly in the large diameter bar. All of those effects should not be neglected in order to obtain accurate results by the SHPB test.

  16. Assymetry of temporal artery diameters during spontaneous attacks of cluster headache

    DEFF Research Database (Denmark)

    Nielsen, Thue H; Tfelt-Hansen, Peer; Iversen, Helle K

    2009-01-01

    BACKGROUND: Cluster headache is characterized by strictly unilateral head pain associated with symptoms of cranial autonomic features. Transcranial Doppler studies showed in most studies a bilateral decreased blood flow velocity in the middle cerebral artery. OBJECTIVE: To investigate whether...... there is a bilateral or unilateral extracranial vasodilation during spontaneous cluster headache attacks. DESIGN AND METHODS: In 9 cluster headache patients, we investigated the luminal diameter of the superficial temporal artery with ultrasound on the headache and headache-free side during and outside cluster...... headache attacks. RESULTS: During cluster headache attacks, the diameter of the superficial temporal artery on the painful side was greater, 1.48 mm, than the diameter on the nonheadache site, 1.14 mm (P

  17. Effect of Rotor Diameter on the Thermal Stresses of a Turbine Rotor Model

    Science.gov (United States)

    Dávalos, J. O.; García, J. C.; Urquiza, G.; Castro-Gómez, L. L.; Rodríguez, J. A.; De Santiago, O.

    2016-04-01

    Thermal stresses in a simplified steam turbine rotor model during a cold startup are analyzed using finite element analysis (FEA). In order to validate the numerical model, an experimental array is developed in which a hollow cylinder is heated with hot air in the external surface. At the thick wall of the cylinder, temperature distribution is measured in real time, while at the same time an algorithm computes thermal stresses. Additional computational fluid dynamics (CFD) calculations are made to obtain magnitudes of velocity and pressure in order to compute convective heat transfer coefficient. The experimental results show good agreement with the FEA computations. To evaluate the effect of rotor diameter size, FEA computations with variation in external and internal diameters are performed. Results show that thermal stresses are proportional to rotor diameter size. Also, zones of higher stress concentration are found in the external and internal surfaces of the rotor.

  18. Characterization of the 80-mm diameter Hamamatsu PMTs for the KM3NeT project

    Energy Technology Data Exchange (ETDEWEB)

    Aiello, S.; Giordano, V.; Leonora, E., E-mail: emanuele.leonora@ct.infn.it [INFN, sezione di Catania, Via S.Sofia 64, 95125, Catania (Italy); Classen, L.; Reubelt, J. [ECAP, Erwin-Rommel-Str. 1, 91052, Erlangen (Germany); Peek, H.; Visser, E. [NIKHEF, Science Park, Amsterdam (Netherlands); Samtleben, D. [NIKHEF, Science Park, Amsterdam, The Netherlands and Leiden University, Leiden Institute of Physics, PO Box 9504, Leiden, 2300 RA (Netherlands); Kalekin, Oleg, E-mail: kalekin@physik.uni-erlangen.de; Collaboration: KM3NeT Collaboration

    2014-11-18

    The optical module designed for the KM3NeT project consists of 31 photomultipliers of 3-inch diameter housed into a 17-inch diameter glass sphere. A proposed photomultiplier was the R12199-02 Hamamatsu 80-mm diameter. 203 of such PMTs have been delivered from Hamamatsu and tested by the KM3NeT groups of NIKHEF-Amsterdam, ECAP-Erlangen and INFN-Catania. Tests have been performed to measure the main parameters, such as gain, transit time spread, dark pulses rate, fraction of spurious pulses, quantum efficiency and effective photocathode size. The main results matched with the requirements of the project. Methods and results are presented in this report.

  19. A comparative study on liquid core formulation on the diameter on the alginate capsules

    Science.gov (United States)

    Ong, Hui-Yen; Lee, Boon-Beng; Radzi, AkmalHadi Ma'; Zakaria, Zarina; Chan, Eng-Seng

    2015-08-01

    Liquid core capsule has vast application in biotechnology related industries such as pharmaceutical, medical, agriculture and food. Formulation of different types of capsule was important to determine the performance of the capsule. Generally, the liquid core capsule with different formulations generated different size of capsule.Therefore, the aim of this project is to investigate the effect of different liquid core solution formulations on the diameter of capsule. The capsule produced by extruding liquid core solutions into sodium alginate solution. Three types of liquid core solutions (chitosan, xanthan gum, polyethylene glycol (PEG)) were investigated. The results showed that there is significant change in capsule diameter despite in different types of liquid core solution were used and a series of capsule range in diameter of 3.1 mm to 4.5 mm were produced. Alginate capsule with chitosan formulation appeared to be the largest capsule among all.

  20. Towards stellar effective temperatures and diameters at one per cent accuracy for future surveys

    CERN Document Server

    Casagrande, L; Glass, I S; Laney, D; Aguirre, V Silva; Datson, J; Andersen, J; Nordström, B; Holmberg, J; Flynn, C; Asplund, M

    2014-01-01

    The apparent size of stars is a crucial benchmark for fundamental stellar properties such as effective temperatures, radii and surface gravities. While interferometric measurements of stellar angular diameters are the most direct method to gauge these, they are still limited to relatively nearby and bright stars, which are saturated in most of the modern photometric surveys. This dichotomy prevents us from safely extending well calibrated relations to the faint stars targeted in large spectroscopic and photometric surveys. Here, we alleviate this obstacle by presenting SAAO near-infrared JHK observations of 55 stars: 16 of them have interferometric angular diameters, and the rest are in common with the 2MASS (unsaturated) dataset, allowing us to tie the effective temperatures and angular diameters derived via the Infrared Flux Method to the interferometric scale. We extend the test to recent interferometric measurements of unsaturated 2MASS stars, including giants, and the metal-poor benchmark target HD122563...

  1. The effect of manufacturing tolerances on the load carrying capacity of large diameter bearings

    Indian Academy of Sciences (India)

    Starvin M S; Manisekar K

    2015-09-01

    This paper deals with simplified 3D finite element (FE) analysis on the effect of manufacturing tolerances on the load carrying capacity of large diameter bearings based on Hertz theory. The nonlinear connector elements are used to model the rolling elements. This model enables us to evaluate the contact load on the rolling elements with relatively reduced calculation time. FE study has been carried out by allocating tolerance on balls and raceways using Monte Carlo simulation technique. The variation in dimension on balls is taken as per IS 2898-1976. A coding has been developed and employed for Monte Carlo simulation. Using the results of Monte Carlo simulation, tolerance has been assigned to the elements of large diameter bearing. From the results of finite element analysis, it is identified that analysis of large diameter bearing with tolerance on ball and raceway will lead to safe design.

  2. Sensitivity Enhancement in Low Cutoff Wavelength Long-Period Fiber Gratings by Cladding Diameter Reduction.

    Science.gov (United States)

    Del Villar, Ignacio; Partridge, Matthew; Rodriguez, Wenceslao Eduardo; Fuentes, Omar; Socorro, Abian Bentor; Diaz, Silvia; Corres, Jesus Maria; James, Stephen Wayne; Tatam, Ralph Peter

    2017-09-13

    The diameter of long-period fiber gratings (LPFGs) fabricated in optical fibers with a low cutoff wavelength was be reduced by hydrofluoric acid etching, enhancing the sensitivity to refractive index by more than a factor of 3, to 2611 nm/refractive index unit in the range from 1.333 to 1.4278. The grating period selected for the LPFGs allowed access to the dispersion turning point at wavelengths close to the visible range of the optical spectrum, where optical equipment is less expensive. As an example of an application, a pH sensor based on the deposition of a polymeric coating was analyzed in two situations: with an LPFG without diameter reduction and with an LPFG with diameter reduction. Again, a sensitivity increase of a factor of near 3 was obtained, demonstrating the ability of this method to enhance the sensitivity of thin-film-coated LPFG chemical sensors.

  3. Prediction of bubble detachment diameter in flow boiling based on force analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chen Deqi [Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400044 (China); Pan Liangming, E-mail: cneng@cqu.edu.cn [Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400044 (China); Ren Song [Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400044 (China)

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer All the forces acting on the growing bubbles are taken into account in the model. Black-Right-Pointing-Pointer The bubble contact diameter has significant effect on bubble detachment. Black-Right-Pointing-Pointer Bubble growth force and surface tension are more significant in narrow channel. Black-Right-Pointing-Pointer A good agreement between the predicted and the measured results is achieved. - Abstract: Bubble detachment diameter is one of the key parameters in the study of bubble dynamics and boiling heat transfer, and it is hard to be measured in a boiling system. In order to predict the bubble detachment diameter, a theoretical model is proposed based on forces analysis in this paper. All the forces acting on a bubble are taken into account to establish a model for different flow boiling configurations, including narrow and conventional channels, upward, downward and horizontal flows. A correlation of bubble contact circle diameter is adopted in this study, and it is found that the bubble contact circle diameter has significant effect on bubble detachment. A new correlation taking the bubble contact circle diameter into account for the evaluation of bubble growth force is proposed in this study, and it is found that the bubble growth force and surface tension force are more significant in narrow channel when comparing with that in conventional channel. A visual experiment was carried out in order to verify present model; and the experimental data from published literature are used also. A good agreement between predicted and measured results is achieved.

  4. Pharyngeal diameter in various head and neck positions during exercise in sport horses

    Science.gov (United States)

    2014-01-01

    Background In equine athletes, dynamic stenotic disorders of the upper airways are often the cause for abnormal respiratory noises and/or poor performance. There are hypotheses, that head and neck flexion may influence the morphology and function of the upper airway and thus could even induce or deteriorate disorders of the upper respiratory tract. Especially the pharynx, without osseous or cartilaginous support is prone to changes in pressure and airflow during exercise. The objective of this study was to develop a method for measuring the pharyngeal diameter in horses during exercise, in order to analyse whether a change of head-neck position may have an impact on the pharyngeal diameter. Results Under the assumption that the width of the epiglottis remains constant in healthy horses, the newly developed method for calculating the pharyngeal diameter in horses during exercise is unsusceptible against changes of the viewing-angle and distance between the endoscope and the structures, which are to be assessed. The quotient of the width of the epiglottis and the perpendicular from a fixed point on the dorsal pharynx to the epiglottis could be used to determine the pharyngeal diameter. The percentage change of this quotient (pharynx-epiglottis-ratio; PE-ratio) in the unrestrained head-neck position against the reference position was significantly larger than that of any other combination of the head-neck positions investigated. A relation between the percentage change in PE-ratio and the degree of head and neck flexion could not be confirmed. Conclusions It could be shown, that the pharyngeal diameter is reduced through the contact position implemented by the rider in comparison to the unrestrained head and neck position. An alteration of the pharyngeal diameter depending on the degree of head and neck flexion (represented by ground and withers angle) could not be confirmed. PMID:24886465

  5. Fatigue acceptance test limit criterion for larger diameter rolled thread fasteners

    Energy Technology Data Exchange (ETDEWEB)

    Kephart, A.R.

    1997-05-01

    This document describes a fatigue lifetime acceptance test criterion by which studs having rolled threads, larger than 1.0 inches in diameter, can be assured to meet minimum quality attributes associated with a controlled rolling process. This criterion is derived from a stress dependent, room temperature air fatigue database for test studs having a 0.625 inch diameter threads of Alloys X-750 HTH and direct aged 625. Anticipated fatigue lives of larger threads are based on thread root elastic stress concentration factors which increase with increasing thread diameters. Over the thread size range of interest, a 30% increase in notch stress is equivalent to a factor of five (5X) reduction in fatigue life. The resulting diameter dependent fatigue acceptance criterion is normalized to the aerospace rolled thread acceptance standards for a 1.0 inch diameter, 0.125 inch pitch, Unified National thread with a controlled Root radius (UNR). Testing was conducted at a stress of 50% of the minimum specified material ultimate strength, 80 Ksi, and at a stress ratio (R) of 0.10. Limited test data for fastener diameters of 1.00 to 2.25 inches are compared to the acceptance criterion. Sensitivity of fatigue life of threads to test nut geometry variables was also shown to be dependent on notch stress conditions. Bearing surface concavity of the compression nuts and thread flank contact mismatch conditions can significantly affect the fastener fatigue life. Without improved controls these conditions could potentially provide misleading acceptance data. Alternate test nut geometry features are described and implemented in the rolled thread stud specification, MIL-DTL-24789(SH), to mitigate the potential effects on fatigue acceptance data.

  6. Correlation between Central Venous Pressure and Inferior Vena Cava Sonographic Diameter; Determining the Best Anatomic Location

    Directory of Open Access Journals (Sweden)

    Bahman naghipour

    2016-04-01

    Full Text Available Introduction: The correlation of central venous pressure (CVP with inferior vena cava (IVC sonographic diameter has been reported in several studies. However, few studies have attempted to find the best anatomic location of measurement. Therefore, the purpose of this study was determining the best anatomic location to find precise correlation between CVP and IVC diameter using transesophageal echocardiography (TEE. Methods: In the present diagnostic accuracy study, patients in need of central venous catheterization and TEE were enrolled. Maximum diameter of IVC were measured during expiratory phase of respiratory cycle at the level of diaphragm, 2cm above the diaphragm and at the point of entry into the right atrium using SonoSite TEE device. CVP was measured using an electronic transducer connected to the central venous line. The best location for sonography was determined via calculating and comparing area under the receiver operating characteristics (ROC curve (AUC. Results: 39 patients were enrolled (53.8% female. Mean CVP was 6.8 ± 1.4 mmHg and 25 (64.1% patients had normal CVP, while 14 (35.9% showed elevated CVP (> 6 mmHg. Evaluating AUC showed that IVC diameter (p = 0.01, aorta diameter (p = 0.01 and IVC / aorta ratio (p = 0.004 had acceptable correlation with CVP. Point of entry of IVC into the right atrium with AUC of 0.98 (95% CI: 0.95 – 1.00 was the location of highest correlation with CVP. Conclusion: Based on the present findings, the IVC sonographic diameter and IVC / aorta ratio had acceptable correlation with CVP at the level of IVC entry into the right atrium.

  7. Effect of Anodic Alumina Oxide Pore Diameter on the Crystallization of Poly(butylene adipate).

    Science.gov (United States)

    Sun, Xiaoli; Fang, Qunqun; Li, Huihui; Ren, Zhongjie; Yan, Shouke

    2016-04-05

    Poly(butylene adipate) (PBA) was infiltrated into the anodic alumina oxide (AAO) templates with the pore diameter of around 30, 70, and 100 nm and PBA nanotubes with different diameters were prepared. The crystallization and phase transition behavior of the obtained PBA nanotubes capped in the nanopores have been explored by using X-ray diffraction and differential scanning calorimetry. Only α-PBA crystals form in the bulk sample during nonisothermal crystallization. By contrast, predominant β-PBA crystals form in the AAO templates. The β-PBA crystals formed in the nanopores with pore diameter less than 70 nm prefer to adopt an orientation with their b-axis parallel to the long axis of the pore. During the melt recrystallization, it was found that the critical temperature (Tβ), below which pure β-crystals form, is 20 °C for bulk PBA. It drops down significantly with the pore diameter for the PBA in the AAO template. Moreover, the β-crystals in the porous template exhibit larger lattice parameters compared with the bulk crystals. By monitoring the change of β-crystals in the heating process, it was found that β-crystals in the AAO template with the pore diameter of 30 nm (D30) melt directly while the β-crystals transform to α-crystals in the template with the pore diameter of 100 nm (D100). The intensity of (020) Bragg peak of β-crystals decreases at a similar rate in both D30 and D100 but disappears at a relatively lower temperature in D30. On the other hand, the β(110) peak intensity of β-PBA crystals formed in the D100 template decreases first at slower rate before α crystals appear, and then at a faster rate once the β to α phase transition takes place.

  8. Continuous retinal vessel diameter measurements: the future in retinal vessel assessment?

    Science.gov (United States)

    Heitmar, Rebekka; Blann, Andrew D; Cubbidge, Robert P; Lip, Gregory Y H; Gherghel, Doina

    2010-11-01

    To establish an alternative method, sequential and diameter response analysis (SDRA), to determine dynamic retinal vessel responses and their time course in serial stimulation compared with the established method of averaged diameter responses and standard static assessment. SDRA focuses on individual time and diameter responses, taking into account the fluctuation in baseline diameter, providing improved insight into reaction patterns when compared with established methods as delivered by retinal vessel analyzer (RVA) software. SDRA patterns were developed with measurements from 78 healthy nonsmokers and subsequently validated in a group of 21 otherwise healthy smokers. Fundus photography and retinal vessel responses were assessed by RVA, intraocular pressure by contact tonometry, and blood pressure by sphygmomanometry. Compared with the RVA software method, SDRA demonstrated a marked difference in retinal vessel responses to flickering light (P SDRA showed a strong relation between baseline retinal vessel diameter and subsequent dilatory response in both healthy subjects and smokers (P = 0.001). The RVA software was unable to detect this difference or to find a difference in retinal vessel arteriovenous ratio between smokers and nonsmokers (P = 0.243). However, SDRA revealed that smokers' vessels showed both an increased level of arterial baseline diameter fluctuation before flicker stimulation (P = 0.005) and an increased stiffness of retinal arterioles (P = 0.035) compared with those in nonsmokers. These differences were unrelated to intraocular pressure or systemic blood pressure. SDRA shows promise as a tool for the assessment of vessel physiology. Further studies are needed to explore its application in patients with vascular diseases.

  9. Forecasting Fruit Diameter of ‘Fuji’Apples (Malus pumila Mill )at Harvest During Early Growing Season

    Institute of Scientific and Technical Information of China (English)

    SONG Guo-qing; YU Ke-shun; LI Shao-hua; LIU Guo-jie; MENG Zhao-qing; ZHU Jun

    2002-01-01

    The fruit growth evolution on 35 tagged‘Fuji'apple trees was studied in three successive growing seasons from 1994 to 1996 to explore a new method for forecasting the fruit diameter at harvest during early growing season. Daily fruit growth rate (DFGR) (based on fruit diameter, fruit dry weight, fruit fresh weight, or fruit volume) during the early growing season, 30 - 50 d after full bloom (DAFB), or during midgrowing season (60 - 120 DAFB), displayed a strong positive linear correlation with the fruit diameter at harvest, and the correlation between the fruit diameter at harvest and DFGR during early and mid-growing season was much better than that between the fruit diameter at harvest and either fruit diameter at a given time or the relative growth rate during early or mid-growing season. The fruit diameters obtained in the field were compared with the mean fruit diameters estimated based on different criteria, such as DFGRs (based on fruit diameter, fruit dry weight, fruit fresh weight, or fruit volume) during early and mid-growing season, and fruit diameter at 120 DAFB. Results showed that daily growth rate of fruit diameter during 30 - 50 DAFB was the best criterion for forecasting fruit diameter at harvest. There was no significant difference in mean fruit diameter between the value measured in the field at harvest and that estimated based on the daily growth rate of fruit diameter during 30 - 50 DAFB (equations for forecasting: y = 153. 571 x + 73. 492) either for the individual trees or for different vigor groups of trees. Daily growth rate of fruit diameter during 30 - 50 DAFB can be used as the basis for forecasting fruit diameter at harvest.

  10. Wiener Index, Diameter, and Stretch Factor of a Weighted Planar Graph in Subquadratic Time

    DEFF Research Database (Denmark)

    Wulff-Nilsen, Christian

    We solve three open problems: the existence of subquadratic time algorithms for computing the Wiener index (sum of APSP distances) and the diameter (maximum distance between any vertex pair) of a planar graph with non-negative edge weights and the stretch factor of a plane geometric graph (maximum...... over all pairs of distinct vertices of the ratio between the graph distance and the Euclidean distance between the two vertices). More specifically, we show that the Wiener index and diameter can be found in O(n^2*(log log n)^4/log n) worst-case time and that the stretch factor can be found in O(n^2...

  11. Growth of laser damage in fused silica: diameter to depth ratio

    Energy Technology Data Exchange (ETDEWEB)

    Norton, M A; Adams, J J; Carr, C W; Donohue, E E; Feit, M D; Hackel, R P; Hollingsworth, W G; Jarboe, J A; Matthews, M; Rubenchik, A M; Spaeth, M L

    2007-10-29

    Growth of laser initiated damage plays a major role in determining optics lifetime in high power laser systems. Previous measurements have established that the lateral diameter grows exponentially. Knowledge of the growth of the site in the propagation direction is also important, especially so when considering techniques designed to mitigate damage growth, where it is required to reach all the subsurface damage. In this work, we present data on both the diameter and the depth of a growing exit surface damage sites in fused silica. Measured growth rates with both 351 nm illumination and with combined 351 nm and 1054 nm illumination are discussed.

  12. Ultrasonographic measurement of normal common bile duct diameter and its correlation with age, sex and anthropometry.

    Science.gov (United States)

    Lal, Nidhi; Mehra, Simmi; Lal, Vivek

    2014-12-01

    Ultrasonography is the diagnostic method of choice for visualization and rational work-up of abdominal organs. The dilatation of the common bile duct helps distinguish obstructive from non-obstructive causes of jaundice. Availability of normal measurements of the common bile duct is therefore important. There exists significant variations in the anthropometric features of various populations, regions and races. Study was conducted to obtain data on sonographically measured diameters of common bile duct in a series of normal Rajasthani population and to measure its correlation with age, sex and anthropometry. Cross-sectional hospital-based study conducted at Mahatma Gandhi Medical College and Hospital, Jaipur, India. Study included 200 participants with equal proportion belonging to either sex. Common bile duct was measured at three locations- at the porta hepatis, in the most distal aspect of head of pancreas and mid-way between these points. Anthropometric measurements including height, weight, chest circumference, circumference at transpyloric plane, circumference at umbilicus and circumference at hip were obtained using standard procedures. Univariable analysis with measures of frequency and standard deviation and bivariable analysis using correlation. Mean age of study subjects was 34.5 years (Range 18-85 years). Mean diameters of the common bile duct in the three locations were: proximal, 4.0 mm (SD 1.02 mm); middle, 4.1 mm (SD 1.01 mm); and distal, 4.2 mm (SD 1.01 mm) and overall mean for all measures 4.1 mm (SD 1.01 mm). Average diameter ranged from 2.0 mm to 7.9 mm, with 95 percent of the subjects having a diameter of less than 6 mm. We observed a statistically significant relation of common bile duct with age, along with a linear trend. There was no statistically significant difference in common bile duct diameter between male and female subjects. The diameter did not show any statistically significant correlation with any of the anthropometric

  13. On Diameter at Breast Height%小议“胸径”

    Institute of Scientific and Technical Information of China (English)

    刘海桑

    2011-01-01

    木材的胸径测量标准不统一导致了混乱和纠纷,对胸径不统一的原因进行分析,提出胸径的测量标准应统一,米径不能作为胸径。%There are some confusion and disputes on wood diameter at breast height (DBH) for the lack of uniform standards. Based on the reason analysis of the inconsistent DBH measurement, the anthor proposed that the measurement of DBH should be unified and DBH should not be replaced by "diameter at one meter height".

  14. The $C^0$-inextendibility of the Schwarzschild spacetime and the spacelike diameter in Lorentzian Geometry

    CERN Document Server

    Sbierski, Jan

    2015-01-01

    The maximal analytic Schwarzschild spacetime is manifestly inextendible as a Lorentzian manifold with a twice continuously differentiable metric. In this paper, we prove the stronger statement that it is even inextendible as a Lorentzian manifold with a continuous metric. To capture the obstruction to continuous extensions through the curvature singularity, we introduce the notion of the spacelike diameter of a globally hyperbolic region of a Lorentzian manifold with a merely continuous metric and give a sufficient condition for the spacelike diameter to be finite. The investigation of low-regularity inextendibility criteria is motivated by the strong cosmic censorship conjecture.

  15. Missing correlation of retinal vessel diameter with high-altitude headache

    Science.gov (United States)

    Willmann, Gabriel; Fischer, M Dominik; Schommer, Kai; Bärtsch, Peter; Gekeler, Florian; Schatz, Andreas

    2014-01-01

    The most common altitude-related symptom, high-altitude headache (HAH), has recently been suggested to originate from restricted cerebral venous drainage in the presence of increased inflow caused by hypoxia. In support of this novel hypothesis, retinal venous distension was shown to correlate with the degree of HAH. We quantified for the first time retinal vessel diameter changes at 4559 m using infrared fundus images obtained from a state of the art Spectralis™ HRA+OCT with a semiautomatic VesselMap 1® software. High-altitude exposure resulted in altered arterial and venous diameter changes at high altitude, however, independent of headache burden. PMID:25356382

  16. Casting of aluminum alloy strip using an unequal diameter twin roll caster

    OpenAIRE

    T. Haga; Inui, H.; H. Watari; S. Kumai

    2008-01-01

    Purpose: of this paper is to clear the property and ability of an unequal diameter twin roll caster to castcommercial size strip. Therefore, 400mm-width strip was cast as first step. Surface-condition, microstructure andmechanical property of the strip was investigated.Design/methodology/approach: Method used in the present study was an unequal diameter twin roll caster.This method was devised to realize easy operation of the twin roll casting and increase of casting speed.Findings: are that ...

  17. The Measurement of Solar Diameter and Limb Darkening Function with the Eclipse Observations. Thesis work

    CERN Document Server

    Raponi, Andrea

    2013-01-01

    A discussion of the solar diameter and its variations must be linked to the limb darkening function (LDF). We introduce a new method to perform high resolution astrometry of the solar diameter from the ground, through the observations of eclipses, using the luminosity evolution of Baily's Bead and the profile of the lunar edge available from satellite data. The method proposed is applied for the videos of the eclipse on 15 January 2010 recorded in Uganda and in India. We obtained a detailed profile constraining the inflection point position. The result suggests reconsidering the evaluations of the historical eclipses observed with a naked eye.

  18. The Effects of Guide Pads on Bore Diameter Enlargement Magnitude in Deep Hole Drilling

    Directory of Open Access Journals (Sweden)

    Zhang Huang

    2016-01-01

    Full Text Available Deep hole machining accuracy plays a crucial role in product’s quality. The results of an investigation into the machining accuracy of deep drilling holes which highlights problems of bore diameter enlargement magnitude assessment are presented in this paper. Through the study of BTA deep drilling tool properties and mechanism, as well as the formation rule of deep hole surface, clarified the burnishing mechanism of guide pad in deep hole drilling, and obtained the directly relationship between surface formation rule and the guide pad. After drilling experimentrevealed the effect of guide pad on bore diameter enlargement magnitude.

  19. Indirect and direct methods for measuring a dynamic throat diameter in a solid rocket motor

    Science.gov (United States)

    Colbaugh, Lauren

    In a solid rocket motor, nozzle throat erosion is dictated by propellant composition, throat material properties, and operating conditions. Throat erosion has a significant effect on motor performance, so it must be accurately characterized to produce a good motor design. In order to correlate throat erosion rate to other parameters, it is first necessary to know what the throat diameter is throughout a motor burn. Thus, an indirect method and a direct method for determining throat diameter in a solid rocket motor are investigated in this thesis. The indirect method looks at the use of pressure and thrust data to solve for throat diameter as a function of time. The indirect method's proof of concept was shown by the good agreement between the ballistics model and the test data from a static motor firing. The ballistics model was within 10% of all measured and calculated performance parameters (e.g. average pressure, specific impulse, maximum thrust, etc.) for tests with throat erosion and within 6% of all measured and calculated performance parameters for tests without throat erosion. The direct method involves the use of x-rays to directly observe a simulated nozzle throat erode in a dynamic environment; this is achieved with a dynamic calibration standard. An image processing algorithm is developed for extracting the diameter dimensions from the x-ray intensity digital images. Static and dynamic tests were conducted. The measured diameter was compared to the known diameter in the calibration standard. All dynamic test results were within +6% / -7% of the actual diameter. Part of the edge detection method consists of dividing the entire x-ray image by an average pixel value, calculated from a set of pixels in the x-ray image. It was found that the accuracy of the edge detection method depends upon the selection of the average pixel value area and subsequently the average pixel value. An average pixel value sensitivity analysis is presented. Both the indirect

  20. Production of a Uniform ECR Plasma Using Large Diameter Multi Slot Antennas

    OpenAIRE

    上田, 洋子; 寺西, 秀明; 田中, 雅慶; 篠原, 俊二郎; 河合, 良信

    1994-01-01

    A uniform ECR plasma is produced with a multi slot antenna of 280mm in diameter. The radial profile of the ion saturation current density is examined as a function of microwave power and pressure. The radial uniformity of the ion saturation current density is within pm3% over 8 inches in diameter for the input microwave power lkW at pressure of 2mTorr. Furthermore, the deposition of a-Si:H films is attempted on glass substrates using mixture SiH4/He. When the microwave power is increased, the...

  1. The luminosity-diameter relation for disk galaxies in different environments

    Energy Technology Data Exchange (ETDEWEB)

    Girardi, M.; Biviano, A.; Giuricin, G.; Mardirossian, F.; Mezzetti, M. (Scuola Internazionale Superiore di Studi Avanzati, Trieste (Italy) Trieste Universita (Italy) Centro Interuniversitario Regionale di Astrofisica e Cosmologia, Trieste (Italy))

    1991-01-01

    Several samples of disk galaxies have been collected in order to study, in each of them, the relation between the blue total corrected absolute magnitude and the absolute corrected isophotal diameter. These luminosity-diameter relations have been compared to detect a possible dependence on the density of the galaxy environment. No significant differences have been found among the several relations, especially if selection criteria relative to the various samples are taken into account. This result is in disagreement with several previous claims. 61 refs.

  2. Contrast and stability of the axon diameter index from microstructure imaging with diffusion MRI

    DEFF Research Database (Denmark)

    Dyrby, Tim B; Søgaard, Lise V; Hall, Matt G

    2013-01-01

    (max) ) on a scanner influence the sensitivity to a range of axon diameters. Multishell high-angular-diffusion-imaging (HARDI) protocols for G(max) of 60, 140, 200, and 300 mT/m were optimized for the pulsed-gradient-spin-echo (PGSE) sequence. Data were acquired on a fixed monkey brain and Monte-Carlo simulations......(max) for enhancing contrast between axon diameter distributions and are, therefore, relevant in general for microstructure imaging methods and highlight the need for increased G(max) on future commercial systems. Magn Reson Med, 2012. © 2012 Wiley Periodicals, Inc....

  3. Evaluating Primary Dendrite Trunk Diameters in Directionally Solidified Al-Si Alloys

    Science.gov (United States)

    Grugel, R. N.; Tewari, S. N.; Poirier, D. R.

    2014-01-01

    The primary dendrite trunk diameters of Al-Si alloys that were directionally solidified over a range of processing conditions have been measured. These data are analyzed with a model based primarily on an assessment of secondary dendrite arm dissolution in the mushy zone. Good fit with the experimental data is seen and it is suggested that the primary dendrite trunk diameter is a useful metric that correlates well with the actual solidification processing parameters. These results are placed in context with the limited results from the aluminium - 7 wt. % silicon samples directionally solidified aboard the International Space Station as part of the MICAST project.

  4. Influence Of Process Conditions On Melt Blown Web Structure. Part IV - Fiber Diameter

    Directory of Open Access Journals (Sweden)

    Randall R. Bresee

    2006-08-01

    Full Text Available We are continuing an effort to quantitatively measure the influence of processing variables on the structure of polypropylene melt blown webs. In this paper, we report experimental measurements of the influence of die-to-collector distance, primary airflow rate, die temperature, collector speed and resin throughput rate on the diameter of fibers in fully-formed webs. This enabled us to quantitatively compare the influence of these processing variables on fiber diameter as well as achieve greater understanding of the melt blowing process.

  5. Interlayer locking and atomic-scale friction in commensurate small-diameter boron nitride nanotubes

    Science.gov (United States)

    Shin, Homin; Kim, Keun Su; Simard, Benoit; Klug, Dennis D.

    2017-02-01

    Density functional theory applied to small-diameter boron nitride nanotubes (BNNTs) finds out-of-plane structural buckling in contrast to large-diameter tubes that exhibit faceting. Buckling significantly affects interlayer interactions in commensurate double-walled BNNTs. Energy corrugation amplitudes in relative motions of BNNT walls change up to fourfold, depending on interlayer registry relaxation, in marked contrast to carbon nanotubes. Large differences between relaxed and unrelaxed energy corrugations of BNNTs could yield energy dissipation via the strain-induced anelastic relaxation of interlayer locking (or "lattice kinks"), which can be exploited for mechanical damping applications.

  6. Optic nerve sheath diameter: A novel way to monitor the brain

    Directory of Open Access Journals (Sweden)

    Seelora Sahu

    2017-01-01

    Full Text Available Measurement and monitoring of intracranial pressure is pivotal in management of brain injured patients. As a rapid and easily done bed side measurement, ultrasonography of the optic nerve sheath diameter presents itself as a possible replacement of the conventional invasive methods of intracranial pressure management. In this review we go through the evolution of optic nerve sheath diameter measurement as a novel marker of predicting raised intracranial pressure, the modalities by which it can be measured as well as its correlation with the invasive methods of intracranial pressure monitoring.

  7. Control of Separation and Diameter of Ag Nanorods through Self-organized Seeds

    Science.gov (United States)

    Elliott, Paul R.; Stagon, Stephen P.; Huang, Hanchen

    2015-11-01

    This paper proposes a mechanism of controlling the diameter and separation of metallic nanorods from physical vapor deposition through self-organized seeds and experimentally demonstrates the feasibility using Ag as the prototype metal, In as the seed, and Si the substrate. Being non-wetting on Si substrates, deposited In atoms self-organize into islands. Subsequently deposited Ag atoms attach to In islands, rather than to Si substrates, due to preferential bonding and geometrical shadowing. The experimental results show that self-organized In seeds of 5 nm nominal thickness give rise to the best separation and the smallest diameter of Ag nanorods.

  8. Biomechanics and load resistance of small-diameter and mini dental implants: a review of literature.

    Science.gov (United States)

    Hasan, Istabrak; Bourauel, Christoph; Mundt, Torsten; Stark, Helmut; Heinemann, Friedhelm

    2014-02-01

    In recent years, the application of small-diameter and mini dental implants to support removable and fixed prosthesis has dramatically increased. However, the success of these implants under functional biting forces and the reaction of the bone around them need to be analyzed. This review was aimed to present studies that deal with the fatigue life of small-diameter and mini dental implants under normal biting force, and their survival rate. The numerical and experimental studies concluded that an increase in the risk of bone damage or implant failure may be assumed in critical clinical situations and implants with dental implants over 5 years was 98.3-99.4%.

  9. Doppler lidar power, aperture diameter, and FFT size trade-off study

    Science.gov (United States)

    Chester, David B.; Budge, Scott E.

    2017-05-01

    In the design or selection of a Doppler lidar instrument for a spacecraft landing system, it is important to evaluate the balance between performance requirements and cost, weight, and power consumption. Leveraging the capability of LadarSIM, a trade-off study was performed to evaluate the interaction between the laser transmission power, aperture diameter, and FFT size in a Doppler lidar system. For this study the probabilities of detection and false alarm were calculated using LadarSIM to simulate FMCW lidar systems with varying power, aperture diameter, and FFT size. This paper reports the results of this trade-off study.

  10. ON THE TOPOLOGY, VOLUME, DIAMETER AND GAUSS MAP IMAGE OF SUBMANIFOLDS IN A SPHERE

    Institute of Scientific and Technical Information of China (English)

    WU BINGYE

    2004-01-01

    In this paper, the author uses Gauss map to study the topology, volume and diameter of submanifolds in a sphere. It is proved that if there exist ε, 1 ≥ε≥ 0 and a fixed unit simple p-vector a such that the Gauss map g of an n-dimensional complete to Sn, and the volume and diameter of M satisfy εnvol(Sn) ≤vol(M) ≤ vol(Sn)/εand επ≤diam(M) ≤π/ε, respectively. The author also characterizes the case where these inequalities become equalities. As an application, a differential sphere theorem for compact submanifolds in a sphere is obtained.

  11. Experimental Validation and Design Review of Wave Loads on Large-Diameter Monopiles

    OpenAIRE

    Frimann-Dahl, Joakim Fürst

    2015-01-01

    The objective of the thesis work was to explore challenges related to ULS wave loading on offshore wind turbines, with special emphasis on large-diameter inertia-dominated monopile foundations. Experimental studies testing ULS loads on a 6.9-m diameter pile in eight different three-hour sea states were performed in two water depths. The wave conditions were set to represent those at location 2 of Creyke Beck B at Dogger Bank, with specified sea state return periods up to 1000 years. The t...

  12. Calculation method for particle mean diameter and particle size distribution function under dependent model algorithm

    Institute of Scientific and Technical Information of China (English)

    Hong Tang; Xiaogang Sun; Guibin Yuan

    2007-01-01

    In total light scattering particle sizing technique, the relationship among Sauter mean diameter D32, mean extinction efficiency Q, and particle size distribution function is studied in order to inverse the mean diameter and particle size distribution simply. We propose a method which utilizes the mean extinction efficiency ratio at only two selected wavelengths to solve D32 and then to inverse the particle size distribution associated with (Q) and D32. Numerical simulation results show that the particle size distribution is inversed accurately with this method, and the number of wavelengths used is reduced to the greatest extent in the measurement range. The calculation method has the advantages of simplicity and rapidness.

  13. 77 FR 59374 - Certain Small Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe (Under 41/2

    Science.gov (United States)

    2012-09-27

    ...] Certain Small Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe (Under 4\\1/2\\ Inches... and pressure pipe (under 4\\1/2\\ inches) (hereinafter, ``small diameter pipe'') from Japan for the... Resources Ltd. (``CNRL), a Canadian exporter of small diameter pipe, which had requested an administrative...

  14. Theoretical Study of the Effect of Multi-Diameter Distribution on the Mie Scattering Characteristics of Milk Fat

    Institute of Scientific and Technical Information of China (English)

    Jinying Yin∗; Siqi Zhang; Hongyan Yang; Zhen Zhou

    2015-01-01

    To correct the light scattering property parameters of milk fat for improving the detection accuracy, the Mie⁃theory was used to establish a predictive model for light scattering properties of milk fat globule with multi⁃diameter distributions, by means of Monte Carlo approach to simulate actual multi⁃diameter size distribution of milk fat globule in milk fat solution. Scattering coefficient and absorption coefficient of multi⁃diameter distribution milk fat particles were calculated by simulating the particles size distribution in milk fat solution. And the light scattering properties of multi⁃diameter distribution was compared with that of volume mean diameter, Sauter mean diameter and numerical mean diameter in milk fat solution. Theoretical simulation results indicate that the scattering coefficient and absorption coefficient of milk fat particles are determined by the particle size distribution in milk fat solution. There is a distinct difference in scattering characteristics between the milk fat particles with multi⁃diameter distribution and that with mean diameters. Compared to that with multi⁃diameter distribution, the scattering coefficient of the milk fat particles with mean diameter has a maximum mean deviation of 9 042 m-1 . The particle size distribution is not completely determined by the mean diameters. The dependence of the light scattering properties on the particle size distribution should be considered into the model and simulation. Therefore, it is found that the particle size distribution in milk fat solution is an essential and critical factor to significantly improve the detection accuracy of milk fat content.

  15. 76 FR 56397 - Small Diameter Graphite Electrodes from the People's Republic of China: Final Results of the...

    Science.gov (United States)

    2011-09-13

    ... International Trade Administration Small Diameter Graphite Electrodes from the People's Republic of China: Final... results of the first administrative review of the antidumping duty order on small diameter graphite..., through January 31, 2010. See Small Diameter Graphite Electrodes from the People's Republic of China...

  16. 76 FR 36092 - Small Diameter Graphite Electrodes From the People's Republic of China: Extension of Time Limit...

    Science.gov (United States)

    2011-06-21

    ... International Trade Administration Small Diameter Graphite Electrodes From the People's Republic of China... Department'') initiated the administrative review of the antidumping duty order on small diameter graphite... March 7, 2011. See Small Diameter Graphite Electrodes From the People's Republic of China: Preliminary...

  17. 77 FR 40854 - Small Diameter Graphite Electrodes From the People's Republic of China: Final Results of the...

    Science.gov (United States)

    2012-07-11

    ... International Trade Administration Small Diameter Graphite Electrodes From the People's Republic of China: Final... diameter graphite electrodes (SDGEs) from the People's Republic of China (PRC). The review covers 25...: Background On March 6, 2012, the Department published Small Diameter Graphite Electrodes from the People's...

  18. 77 FR 6060 - Small Diameter Graphite Electrodes from the People's Republic of China: Extension of Time Limit...

    Science.gov (United States)

    2012-02-07

    ... International Trade Administration Small Diameter Graphite Electrodes from the People's Republic of China... antidumping duty order on small diameter graphite electrodes from the People's Republic of China (PRC) for the... February 3, 2012. See Small Diameter Graphite Electrodes from the People's Republic of China: Extension of...

  19. 77 FR 15042 - Small Diameter Graphite Electrodes From the People's Republic of China: Amended Final Results of...

    Science.gov (United States)

    2012-03-14

    ... International Trade Administration Small Diameter Graphite Electrodes From the People's Republic of China... the antidumping duty administrative review of small diameter graphite electrodes (``SDGE'') from the... (``the Act''), and 19 CFR 351.224(e). \\1\\ See Small Diameter Graphite Electrodes from the People's...

  20. Analysis of the radius and diameter protocols in terms of pricing telecommunication services

    Directory of Open Access Journals (Sweden)

    Vesna M. Radonjić

    2013-06-01

    Full Text Available Accounting of telecommunication services is closely related to the functions of authentication and authorization. These functions are usually considered together and implemented within the same server using a common protocol. The most renowned protocols for authentication, authorization and accounting are the RADIUS and Diameter protocols.   AAA functions and related protocols   In this chapter, the accounting management architecture developed by IETF is presented. It includes the interaction between network elements, accounting servers and billing and charging servers. Accounting data can be used for management, planning and charging users as well as other (specific purposes. Authentication is the process of confirming a user's digital identity, usually through some type of identifiers and related data. Authorization determines whether a particular entity is authorized to perform an activity.   Basic Functions of the RADIUS Protocol   The RADIUS architecture is based on a client-server model. It uses UDP on the transport layer. Transactions between the client and the server are authenticated, which is achieved by using a common secret key that is never sent through the network. Given the limited resources available to network devices, RADIUS facilitates and centralizes charging end users, provides some protection against active attacks by unauthorized users and it has great support from different network equipment vendors. Although RADIUS is a widely accepted protocol for the mechanisms of authentication, authorization and accounting, it has certain shortcomings that may be caused by the protocol itself or by its poor implementation.   Architecture and Operation of the Diameter Protocol   Diameter is a scalable protocol designed by the IETF working group in order to eliminate shortcomings and functional limitations of the RADIUS protocol and eventually to replace it in the near future. Most of the basic Diameter mechanisms and its

  1. US Army Qualification of Alternative Fuels Specified in MIL-DTL-83133H for Ground Systems Use. Final Qualification Report: JP-8 Containing Synthetic Paraffinic Kerosene Manufactured Via Fischer-Tropsch Synthesis or Hydroprocessed Esters and Fatty Acids

    Science.gov (United States)

    2013-09-01

    hoses, butterfly valves , couplers, adapters, and straight pipe sections. Each pump / engine assembly was subjected to a 400 hour durability test...AAFARS)  Fuel System Supply Point (FSSP)  Petroleum and Water (PAWS) storage, distribution, and handling equipment including pumps, hoses, valves ...components such as pumps, hoses, valves , couplers, adapters, and pipe sections that comprise the typical PAWS bulk fuel and water distribution and

  2. Acute Dermal Irritation Study In New Zealand White Rabbits: Four Alcohol-to-Jet (ATJ) Synthetic Paraffinic Kerosene (SPK) Alternative Jet Fuels Compared With Petroleum-Derived JP-8

    Science.gov (United States)

    2014-09-19

    visceral cavities will be conducted on all animals found dead or euthanized in extremis. Animals euthanized following study termination will be discarded...discomfort, distress or pain to animals. All methods are described in this study protocol or in written laboratory SOPS. • Animals that experience...severe or chronic pain or distress that cannot be relieved will be painlessly euthanized as deemed appropriate by the veterinary staff and Study

  3. Quantitative Measurement of Changes in Retinal Vessel Diameter in Ocular Fundus Images

    DEFF Research Database (Denmark)

    Pedersen, Lars; Grunkin, Michael; Ersbøll, Bjarne Kjær

    1999-01-01

    The Change in diameter of retinal vessels as a funcion of increasing distance to the optic disc is believed to be indicative of the risk level of various vascular diseases such as generalised arteriosclerosis and Diabetes Mellitus. In particular, Focal Arteriolar Narrowing (FAN) is considered...

  4. RUBBING TEST RESPONSES OF THE SKIN TO MAN-MADE MINERAL FIBERS OF DIFFERENT DIAMETERS

    NARCIS (Netherlands)

    STAMWESTERVELD, EB; COENRAADS, PJ; VANDERVALK, PGM; DEJONG, MCJM; FIDLER, [No Value

    The irritant potency of 5 types of insulation wools (2 types of rockwool and 3 types of glasswool) were studied on the basis of their differences in diameter by a standardized rubbing test. Assessment was done by laser Doppler flowmetry (LDF) and erythema scores. Insulation wools show a wide

  5. A Model Based on Environmental Factors for Diameter Distribution in Black Wattle in Brazil

    Science.gov (United States)

    Sanquetta, Carlos Roberto; Behling, Alexandre; Dalla Corte, Ana Paula; Péllico Netto, Sylvio; Rodrigues, Aurelio Lourenço; Simon, Augusto Arlindo

    2014-01-01

    This article discusses the dynamics of a diameter distribution in stands of black wattle throughout its growth cycle using the Weibull probability density function. Moreover, the parameters of this distribution were related to environmental variables from meteorological data and surface soil horizon with the aim of finding a model for diameter distribution which their coefficients were related to the environmental variables. We found that the diameter distribution of the stand changes only slightly over time and that the estimators of the Weibull function are correlated with various environmental variables, with accumulated rainfall foremost among them. Thus, a model was obtained in which the estimators of the Weibull function are dependent on rainfall. Such a function can have important applications, such as in simulating growth potential in regions where historical growth data is lacking, as well as the behavior of the stand under different environmental conditions. The model can also be used to project growth in diameter, based on the rainfall affecting the forest over a certain time period. PMID:24932909

  6. Analysis of the Influence of Fibre Diameter on Wirescanner Beam Profile Measurements

    CERN Document Server

    King, Quentin

    1988-01-01

    It is often important to be able to measure beam profiles in regions where the beam size is very small. Following concern that the profile measurement might be affected by having a beam size of the same order as the diameter of the wirescanner fibre, the effect was analysed numerically, and the results are presented.

  7. Induction of embolism in xylem conduits of pre-defined diameter

    NARCIS (Netherlands)

    Ieperen, van W.; Nijsse, J.; Keijzer, C.J.; Meeteren, van U.

    2001-01-01

    A new method is presented that enables the induction of embolisms in a fraction of all xylem vessels, based on diameter, at one cut end of a stem segment. The method is based on the different capillary characteristic of xylem vessels of different cross-sectional size. To verify the method, air

  8. In situ tissue engineering of functional small-diameter blood vessels by host circulating cells only

    NARCIS (Netherlands)

    Talacua, Hanna; Smits, Anthal I P M; Muylaert, Dimitri E P; Van Rijswijk, Jan Willem; Vink, Aryan; Verhaar, Marianne C.; Driessen-Mol, Anita; Van Herwerden, Lex A.; Bouten, Carlijn V C; Kluin, Jolanda; Baaijens, Frank P T

    2015-01-01

    Inflammation is a natural phase of the wound healing response, which can be harnessed for the in situ tissue engineering of small-diameter blood vessels using instructive, bioresorbable synthetic grafts. This process is dependent on colonization of the graft by host circulating cells and subsequent

  9. Spontaneous high frequency diameter oscillations of larger retinal arterioles are reduced in type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Bek, Toke; Jeppesen, Peter; Kanters, Jørgen K.

    2013-01-01

    Diabetic retinopathy is characterized by morphological changes in the retina secondary to disturbances in retinal blood flow. Vasomotion is a mechanism for regulating blood flow by spontaneous oscillations in the diameter of retinal resistance arterioles, and has been shown to be disturbed outsid...

  10. The Effect of Sunlight in Parenchyma Pith Cells Diameter of Manihot esculenta

    Science.gov (United States)

    Susanti, D.; Aziz, D. N.; Astuti, W.; Nuraeni, E.

    2017-03-01

    Sunlight is one of the factors that effect on the grow of a plant. Manihot esculenta is one of the plants that easily found in Indonesia because its role as staple food. The aim of this research is to know the correlation between sunlight the grow of parenchyma pith cells diameter of Manihot esculenta. Independent variable in this research is sunlight, and dependent variable is the parenchyma pith cells diameter of Manihot esculenta. Data was collected is in qualitative and quantitative form. Qualitative data gotten gained by morphology observation. The parenchyma pith cells of Manihot esculenta that is affected by sunlight in 1310 x 10 Lux, morphologically has hexagon, cell walls thick, solid state, and regular composition. Meanwhile, the parenchyma pith cells that has less sunlight (363 x 10 Lux) has a hexagon shape, thin cell walls thin, soft state, and irregular composition. Qualitative data suported by quantitative data. The size of parenchyma pith cells diameter that is affected by sunlight in 1310 x 10 Lux 96,4 µm. While, the stem parenchyma pith cells diameter empulur that has less sunlight (363 x 10 Lux) is 129,8 µm.

  11. Determination of wave intensity in flexible tubes using measured diameter and velocity.

    Science.gov (United States)

    Feng, J; Khir, A W

    2007-01-01

    Wave intensity (WI) is a hemodynamics index, which is the product of changes in pressure and velocity across the wave-front. Wave Intensity Analysis, which is a time domain technique allows for the separation of running waves into their forward and backward directions and traditionally uses the measured pressure and velocity waveforms. However, due to the possible difficulty in obtaining reliable pressure waveforms non-invasively, investigating the use of wall displacement instead of pressure signals in calculating WI may have clinical merits. In this paper, we developed an algorithm in which we use the measured diameter of flexible tube's wall and flow velocity to separate the velocity waveform into its forward and backward directions. The new algorithm is also used to separate wave intensity into its forward and backward directions. In vitro experiments were carried out in two sized flexible tubes, 12mm and 16mm in diameters, each is of 2 m in length. Pressure, velocity and diameter were taken at three measuring sites. A semi-sinusoidal wave was generated using a piston pump, which ejected 40cc water into each tube. The results show that separated wave intensity into the forward and backward directions of the new algorithm using the measured diameter and velocity are almost identical in shape to those traditionally using the measured pressure and velocity. We conclude that the new algorithm presented in this work, could have clinical advantages since the required information can be obtained non-invasively.

  12. Effects of diameter, length, and circuit pressure on sound conductance through endotracheal tubes.

    Science.gov (United States)

    Räsänen, Jukka O; Rosenhouse, Giora; Gavriely, Noam

    2006-07-01

    We evaluated the acoustic frequency response of endotracheal tubes (ETs) to assess their effect on respiratory system sound transmission studies. White noise 150-3300 Hz was introduced into 4.0-, 6.0-, and 8.0-mm ETs and recorded at their proximal and distal ends. Four tubes of each size were studied at their original and normalized lengths, in straight and bent configurations, and at circuit pressures from 0 to 20 cmH2O. The characteristics of the sound transmission were compared using an analysis of variance for repeated measures. The average transmission amplitude varied directly with tube diameter. The position of peaks and troughs on the amplitude frequency distribution depended on tube length but not on tube diameter. The angle of the phase-frequency plot correlated well with the length of the tube and was independent of its diameter. A 90 degrees bend in the tube had no effect on its sound transmission. Increasing the circuit pressure above ambient modified the frequency response only if volume changes occurred in the test lung. When used to conduct sound into the respiratory system an ET affects the incident signal predictably depending on its length and diameter but not on its curvature or circuit pressure.

  13. The Inferior Vena Cava Diameter as a Marker of Dry Weight in Chronic Hemodialyzed Patients

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    We have previously reported that the diameter of the inferior vena cava(IVC) reflects the amount of body fluid in hemodialyzed (HD) patients. The present study was undertaken to depict the criteria of IVC diameters for determining dry weight (DW) in anuric HD patients. In healthy subjects, the maximal diameters during quiet expiration (IVCe) and the minimal diameters during quiet inspiration (IVCi) were (16.7±3.2) and (5.7±5.4)mm,respectively (mean±SD).The collapsibility index (CI,1-IVCi/IVCe), which inversely correlates with the central venous pressure,was 0.68±0.29. In anuric HD patients,the IVCe/CI values before and after HD were 14.9±3.2/0.68±0.24 and 8.2±2.3/0.94±0.09, respectively. IVCe decreased proportionally to the amount of ultrafiltration. In HD patients with hypervolemic pulmonary edema, the IVCe and CI values were 22.4±2.9 and 0.22±0.11, respectively. We proposed that IVCe/CI after HD is (8±3)mm/0.9 ± 0.1 as the markers of DW in anuric HD patients and that an IVCe value≥22mm together with a CI≤0.22 implies the warning level of body fluid retention.

  14. The Inferior Vena Cava Diameter as a Marker of Dry Weight in Chronic Hemodialyzed Patients (续)

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    @@ The IVC diameters in HD patients Since BW and stature as well as gender and age were not considered to be determinant factors of the IVC diameters, these factors were not accounted for in evaluating the IVC diameters in HD patients. The IVC diameters of stable anuric HD patients are shown in Table 2. In agreement with our previous observation [7-9] ,the reduction of BW from (51.7±12.6) to (49.3±12.6)kg by ultrafiltration during HD resulted in a significant (P<0.0001)reduction of the IVCe and IVCi from (14.9 ± 3.2) to (6.8±1.9)mm and (5.2±4.2) to (0.1±0.3) mm,respectively. Thus,CI values before and at the end of HD were calculated as (0.68±0.24) and (0.98±0. 05), respectively (P<0.0001).

  15. Analysis of Individual Tree Competition Effect on Diameter Growth of Silver Birch in Estonia

    Directory of Open Access Journals (Sweden)

    Kobra Maleki

    2015-08-01

    Full Text Available Aim of study: The present study evaluates a set of competition indices including spatially explicit indices combined with different competitor selection approaches and non-spatially explicit competition indices. The aim was to quantify and describe the neighbouring effects on the tree diameter growth of silver birch trees. Area of study: Region throughout Estonia. Material and methods: Data from the Estonian Network of Forest Research Plots was used. After quantifying the selected indices, the best non-spatial indices and spatial indices (combined with neighbour selection methods were separately devised into a growth model as a predictor variable to assess the ability of the diameter growth model before and after adding competition measures. To test the species-specific effect on the competition level, the superior indices were recalculated using Ellenberg’s light indicators and incorporated into the diameter growth model. Main results: Statistical analyses showed that the diameter growth is a function of neighbourhood interactions and spatial indices were better growth predictors than non-spatial indices. In addition, the best selections of competitive neighbours were acquired based on the influence zone and the competition elimination angle concepts, and using Ellenberg’s light values had no significant improvement in quantifying the competition effects. Research highlights: Although the best ranking spatial competition measures were superior to the best non-spatial indices, the differences were negligible.

  16. Application of Large-diameter and Long-span Micro-expansive Pumping

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In this article the high strength micro-expansive concrete that has been applied on big-diameter and long-span steel arch bridge is researched. The applications show that the concrete has some merits,such as good fluidity, low bleeding ratio and no segregation, low slump loss, high early strength and high later strength, micro-expansion etc.

  17. In situ tissue engineering of functional small-diameter blood vessels by host circulating cells only

    NARCIS (Netherlands)

    Talacua, Hanna; Smits, Anthal I P M; Muylaert, Dimitri E P; Van Rijswijk, Jan Willem; Vink, Aryan; Verhaar, Marianne C.; Driessen-Mol, Anita; Van Herwerden, Lex A.; Bouten, Carlijn V C; Kluin, Jolanda; Baaijens, Frank P T

    2015-01-01

    Inflammation is a natural phase of the wound healing response, which can be harnessed for the in situ tissue engineering of small-diameter blood vessels using instructive, bioresorbable synthetic grafts. This process is dependent on colonization of the graft by host circulating cells and subsequent

  18. Anomalous diameter dependence of thermal transport in ultra-narrow Si nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Karamitaheri, Hossein, E-mail: karami@iue.tuwien.ac.at [Institute for Microelectronics, TU Wien, Gußhausstraße 27-29/E360, A-1040 Wien (Austria); Department of Electrical Engineering, University of Kashan, Kashan, 87317-51167 (Iran, Islamic Republic of); Neophytou, Neophytos, E-mail: neophytou@iue.tuwien.ac.at [Institute for Microelectronics, TU Wien, Gußhausstraße 27-29/E360, A-1040 Wien (Austria); School of Engineering, University of Warwick, Coventry CV4 7AL (United Kingdom); Kosina, Hans, E-mail: kosina@iue.tuwien.ac.at [Institute for Microelectronics, TU Wien, Gußhausstraße 27-29/E360, A-1040 Wien (Austria)

    2014-01-14

    We present atomistic valence force field calculations of thermal transport in Si nanowires of diameters from 12 nm down to 1 nm. We show that as the diameter is reduced, the phonon density-of-states and transmission function acquire a finite value at low frequency, in contrast to approaching zero as in the bulk material. It turns out that this effect results in what Ziman described as the “problem of long longitudinal waves” [J. M. Ziman, Electrons and Phonons: The Theory of Transport Phenomena in Solids (Clarendon, Oxford, 1962)], which states that the thermal conductivity of a material increases as its length is increased due to the vanishing scattering for long-wavelength phonons. We show that this thermal transport improvement also appears in nanowires as their diameter is decreased below D = 5 nm (not only as the length increases), originating from the increase in the density of the long wavevector modes. The observation is present under ballistic transport conditions, and further enhanced with the introduction of phonon-phonon scattering. Because of this, in such ultra-narrow nanowires, as the diameter is reduced, phonon transport is dominated more and more by lower energy phonons with longer mean-free paths. We show that ∼80% of the heat is carried by phonons with energies less than 5 meV, most with mean-free paths of several hundreds of nanometers.

  19. СOMPACT COMPLEX FOR PROCESSING OF LARGE-DIAMETER PIPES INTO THE ROLLING STEEL PRODUCTS

    Directory of Open Access Journals (Sweden)

    A. В. Steblov

    2016-01-01

    Full Text Available A mini-plant conception for processing of previously used large-diameter pipes into the small-section rolling steel products. Projects with capacity from 15 to 200 thousand tons per year are realized in the UIS.

  20. Correlation of Left Atrial Diameter by Echocardiography and Left Atrial Volume by Computed Tomography

    NARCIS (Netherlands)

    Hof, Irene; Arbab-Zadeh, Armin; Scherr, Daniel; Chilukuri, Karuna; Dalal, Darshan; Abraham, Theodore; Lima, Joao; Calkins, Hugh

    2009-01-01

    Computed Tomography. Introduction: For patients undergoing catheter ablation of atrial fibrillation (AF), left atrial size is a predictor of recurrence of AF during follow-up. For this reason, major clinical trials have used a left atrial diameter (LAD) of more than 5.0 or 5.5 cm, assessed by echoca

  1. Error Ellipsoid Analysis for the Diameter Measurement of Cylindroid Components Using a Laser Radar Measurement System.

    Science.gov (United States)

    Du, Zhengchun; Wu, Zhaoyong; Yang, Jianguo

    2016-05-19

    The use of three-dimensional (3D) data in the industrial measurement field is becoming increasingly popular because of the rapid development of laser scanning techniques based on the time-of-flight principle. However, the accuracy and uncertainty of these types of measurement methods are seldom investigated. In this study, a mathematical uncertainty evaluation model for the diameter measurement of standard cylindroid components has been proposed and applied to a 3D laser radar measurement system (LRMS). First, a single-point error ellipsoid analysis for the LRMS was established. An error ellipsoid model and algorithm for diameter measurement of cylindroid components was then proposed based on the single-point error ellipsoid. Finally, four experiments were conducted using the LRMS to measure the diameter of a standard cylinder in the laboratory. The experimental results of the uncertainty evaluation consistently matched well with the predictions. The proposed uncertainty evaluation model for cylindrical diameters can provide a reliable method for actual measurements and support further accuracy improvement of the LRMS.

  2. Effect of tube-electrode inner diameter on electrochemical discharge machining of nickel-based superalloy

    Directory of Open Access Journals (Sweden)

    Zhang Yan

    2016-08-01

    Full Text Available Nickel-based superalloys are widely employed in modern aircraft engines because of their excellent material characteristics, particularly in the fabrication of film cooling holes. However, the high machining requirement of a large number of film cooling holes can be extremely challenging. The hybrid machining technique of tube electrode high-speed electrochemical discharge drilling (TEHECDD has been considered as a promising method for the production of film cooling holes. Compared with any single machining process, this hybrid technique requires the removal of more complex machining by-products, including debris produced in the electrical discharge machining process and hydroxide and bubbles generated in the electrochemical machining process. These by-products significantly affect the machining efficiency and surface quality of the machined products. In this study, tube electrodes in different inner diameters are designed and fabricated, and the effects of inner diameter on the machining efficiency and surface quality of TEHECDD are investigated. The results show that larger inner diameters could effectively improve the flushing condition and facilitate the removal of machining by-products. Therefore, higher material removal efficiency, surface quality, and electrode wear rate could be achieved by increasing the inner diameter of the tube electrode.

  3. Effect of tube-electrode inner diameter on electrochemical discharge machining of nickel-based superalloy

    Institute of Scientific and Technical Information of China (English)

    Zhang Yan; Xu Zhengyang; Xing Jun; Zhu Di

    2016-01-01

    Nickel-based superalloys are widely employed in modern aircraft engines because of their excellent material characteristics, particularly in the fabrication of film cooling holes. How-ever, the high machining requirement of a large number of film cooling holes can be extremely chal-lenging. The hybrid machining technique of tube electrode high-speed electrochemical discharge drilling (TEHECDD) has been considered as a promising method for the production of film cooling holes. Compared with any single machining process, this hybrid technique requires the removal of more complex machining by-products, including debris produced in the electrical discharge machin-ing process and hydroxide and bubbles generated in the electrochemical machining process. These by-products significantly affect the machining efficiency and surface quality of the machined prod-ucts. In this study, tube electrodes in different inner diameters are designed and fabricated, and the effects of inner diameter on the machining efficiency and surface quality of TEHECDD are inves-tigated. The results show that larger inner diameters could effectively improve the flushing condi-tion and facilitate the removal of machining by-products. Therefore, higher material removal efficiency, surface quality, and electrode wear rate could be achieved by increasing the inner diam-eter of the tube electrode.

  4. A model based on environmental factors for diameter distribution in black wattle in Brazil.

    Science.gov (United States)

    Sanquetta, Carlos Roberto; Behling, Alexandre; Dalla Corte, Ana Paula; Péllico Netto, Sylvio; Rodrigues, Aurelio Lourenço; Simon, Augusto Arlindo

    2014-01-01

    This article discusses the dynamics of a diameter distribution in stands of black wattle throughout its growth cycle using the Weibull probability density function. Moreover, the parameters of this distribution were related to environmental variables from meteorological data and surface soil horizon with the aim of finding a model for diameter distribution which their coefficients were related to the environmental variables. We found that the diameter distribution of the stand changes only slightly over time and that the estimators of the Weibull function are correlated with various environmental variables, with accumulated rainfall foremost among them. Thus, a model was obtained in which the estimators of the Weibull function are dependent on rainfall. Such a function can have important applications, such as in simulating growth potential in regions where historical growth data is lacking, as well as the behavior of the stand under different environmental conditions. The model can also be used to project growth in diameter, based on the rainfall affecting the forest over a certain time period.

  5. Are retinal arteriolar or venular diameters associated with markers for cardiovascular disorders? The Rotterdam Study

    NARCIS (Netherlands)

    M.K. Ikram (Kamran); F.J. de Jong (Frank Jan); J.R. Vingerling (Hans); J.C.M. Witteman (Jacqueline); M.M.B. Breteler (Monique); P.T.V.M. de Jong (Paulus); A. Hofman (Albert)

    2004-01-01

    textabstractPURPOSE: A lower retinal arteriolar-to-venular ratio (AVR) has been suggested to reflect generalized arteriolar narrowing and to predict the risk of cardiovascular diseases. The contribution of the separate arteriolar and venular diameters to this AVR is unknown. Thus,

  6. Magnetomotive forming for precision sizing and joining of large-diameter tubes

    Science.gov (United States)

    Bennight, J. D.; Schwinghamer, R. J.

    1969-01-01

    Portable electromagnetic coil enables high precision expansion or constriction and joining of large diameter metal tubes. A nonconducting mandrel or forming die is used on the side of the tubes wall opposite the coil. The coil is insulated from the tube by a thin plastic sleeve.

  7. 78 FR 64477 - Welded Large Diameter Line Pipe From Japan: Continuation of Antidumping Duty Order

    Science.gov (United States)

    2013-10-29

    ... or not stenciled. This product is normally produced according to American Petroleum Institute (API... wall thickness measuring greater than 0.688 inches in grades X60 or greater. Having an outside diameter... X52 through X56, and with wall thickness measuring greater than 0.875 inches in grades X60 or...

  8. 75 FR 38989 - Welded Large Diameter Line Pipe From Japan: Notice of Rescission of Antidumping Duty...

    Science.gov (United States)

    2010-07-07

    ... or not stenciled. This product is normally produced according to American Petroleum Institute (API... thickness measuring greater than 0.688 inches in grades X60 or greater. Having an outside diameter greater... through X56, and with wall thickness measuring greater than 0.875 inches in grades X60 or greater....

  9. Fabrication of an Optical Fiber Micro-Sphere with a Diameter of Several Tens of Micrometers

    Directory of Open Access Journals (Sweden)

    Huijuan Yu

    2014-06-01

    Full Text Available A new method to fabricate an integrated optical fiber micro-sphere with a diameter within 100 µm, based on the optical fiber tapering technique and the Taguchi method is proposed. Using a 125 µm diameter single-mode (SM optical fiber, an optical fiber taper with a cone angle is formed with the tapering technique, and the fabrication optimization of a micro-sphere with a diameter of less than 100 µm is achieved using the Taguchi method. The optimum combination of process factors levels is obtained, and the signal-to-noise ratio (SNR of three quality evaluation parameters and the significance of each process factors influencing them are selected as the two standards. Using the minimum zone method (MZM to evaluate the quality of the fabricated optical fiber micro-sphere, a three-dimensional (3D numerical fitting image of its surface profile and the true sphericity are subsequently realized. From the results, an optical fiber micro-sphere with a two-dimensional (2D diameter less than 80 µm, 2D roundness error less than 0.70 µm, 2D offset distance between the micro-sphere center and the fiber stylus central line less than 0.65 µm, and true sphericity of about 0.5 µm, is fabricated.

  10. Estimation of local pulse wave velocity using arterial diameter waveforms: Experimental validation in sheep

    Science.gov (United States)

    Graf, S.; Craiem, D.; Barra, J. G.; Armentano, R. L.

    2011-12-01

    Increased arterial stiffness is associated with an increased risk of cardiovascular events. Estimation of arterial stiffness using local pulse wave velocity (PWV) promises to be very useful for noninvasive diagnosis of arteriosclerosis. In this work we estimated in an instrumented sheep, the local aortic pulse wave velocity using two sonomicrometry diameter sensors (separated 7.5 cm) according to the transit time method (PWVTT) with a sampling rate of 4 KHz. We simultaneously measured aortic pressure in order to determine from pressure-diameter loops (PWVPDLoop), the "true" local aortic pulse wave velocity. A pneumatic cuff occluder was implanted in the aorta in order to compare both methods under a wide range of pressure levels. Mean pressure values ranged from 47 to 101 mmHg and mean proximal diameter values from 12.5. to 15.2 mm. There were no significant differences between PWVTT and PWVPDLoop values (451±43 vs. 447±48 cm/s, p = ns, paired t-test). Both methods correlated significantly (R = 0.81, p<0.05). The mean difference between both methods was only -4±29 cm/s, whereas the range of the limits of agreement (mean ± 2 standard deviation) was -61 to +53 cm/s, showing no trend. In conclusion, the diameter waveforms transit time method was found to allow an accurate and precise estimation of the local aortic PWV.

  11. Diameter grouping in bulk samples of single-walled carbon nanotubes from optical absorption spectroscopy

    NARCIS (Netherlands)

    Golden, M.S.; Fink, J.; Dunsch, L.; Bauer, H.-D.; Reibold, M.; Knupfer, M.; Friedlein, R.; Pichler, T.; Jost, O.

    1999-01-01

    The influence of the synthesis parameters on the mean characteristics of single-wall carbon nanotubes in soot produced by the laser vaporization of graphite has been analyzed using optical absorption spectroscopy. The abundance and mean diameter of the nanotubes were found to be most influenced by

  12. Error analysis and corrections to pupil diameter measurements with Langley Research Center's oculometer

    Science.gov (United States)

    Fulton, C. L.; Harris, R. L., Jr.

    1980-01-01

    Factors that can affect oculometer measurements of pupil diameter are: horizontal (azimuth) and vertical (elevation) viewing angle of the pilot; refraction of the eye and cornea; changes in distance of eye to camera; illumination intensity of light on the eye; and counting sensitivity of scan lines used to measure diameter, and output voltage. To estimate the accuracy of the measurements, an artificial eye was designed and a series of runs performed with the oculometer system. When refraction effects are included, results show that pupil diameter is a parabolic function of the azimuth angle similar to the cosine function predicted by theory: this error can be accounted for by using a correction equation, reducing the error from 6% to 1.5% of the actual diameter. Elevation angle and illumination effects were found to be negligible. The effects of counting sensitivity and output voltage can be calculated directly from system documentation. The overall accuracy of the unmodified system is about 6%. After correcting for the azimuth angle errors, the overall accuracy is approximately 2%.

  13. Maximum tumor diameter is not an independent prognostic factor in high-risk localized prostate cancer

    NARCIS (Netherlands)

    Oort, van I.M.; Witjes, J.A.; Kok, D.E.G.; Kiemeney, L.A.; Hulsbergen-van de Kaa, C.A.

    2008-01-01

    Previous studies suggest that maximum tumor diameter (MTD) is a predictor of recurrence in prostate cancer (PC). This study investigates the prognostic value of MTD for biochemical recurrence (BCR) in patients with PC, after radical prostatectomy (RP), with emphasis on high-risk localized prostate c

  14. Maximum tumor diameter is not an independent prognostic factor in high-risk localized prostate cancer.

    NARCIS (Netherlands)

    Oort, I.M. van; Witjes, J.A.M.; Kok, D.E.; Kiemeney, L.A.L.M.; Hulsbergen- van de Kaa, C.A.

    2008-01-01

    OBJECTIVES: Previous studies suggest that maximum tumor diameter (MTD) is a predictor of recurrence in prostate cancer (PC). This study investigates the prognostic value of MTD for biochemical recurrence (BCR) in patients with PC, after radical prostatectomy (RP), with emphasis on high-risk localize

  15. Production of small diameter high-temperature-strength refractory metal wires

    Science.gov (United States)

    Petrasek, D. W.; Signorelli, R. A.; King, G. W.

    1973-01-01

    Special thermomechanical techniques (schedules) have been developed to produce small diameter wire from three refractory metal alloys: colombian base alloy, tantalum base alloy, and tungsten base alloy. High strengths of these wires indicate their potential for contributing increased strength to metallic composites.

  16. 77 FR 37873 - Small Diameter Graphite Electrodes From the People's Republic of China: Initiation of...

    Science.gov (United States)

    2012-06-25

    ..., the use of the merchandise, the channels of marketing and the cost of any modification relative to the... characteristics; (2) expectations of ultimate users; (3) use of merchandise; (4) channels of marketing; and (5... introduction of alleged SDGEs and that the diameter increase provides no significant added commercial...

  17. Case Study: Effect of Handrim Diameter on Performance in a Paralympic Wheelchair Athlete

    Science.gov (United States)

    Costa, Gabriel Brizuela; Rubio, Miguel Polo; Belloch, Salvador Llana; Soriano, Pedro Perez

    2009-01-01

    This study, with a top T-52 class athlete, determines the relationship between stroke frequency (SF) and push time (PT) and wheelchair velocity (Wv) using different handrim diameters (HD) and the effect of different HDs on the athlete's heart rate (HR) and blood lactate (LACT) at competition speeds. Wv shows a linear-direct relationship with SF…

  18. On a bound for the diameter of Cayley networks of symmetric groups generated by transposition trees

    CERN Document Server

    Ganesan, Ashwin

    2011-01-01

    A problem of both theoretical and practical interest is to determine estimates or bounds for the diameter of Cayley graphs of groups, and to know for which cases the bounds are exact or how far away the bounds can be from the true value in the worst case. Let $\\Gamma$ be a Cayley graph of the symmetric group on $n$ letters generated by a transposition tree $T$. In \\cite{Akers:Krishnamurthy:1989} \\cite{Hahn:Sabidussi:1997}, it is shown that the diameter of $\\Gamma$ is bounded as $$\\diam(\\Gamma) \\le \\max_{\\pi \\in S_n} {c(\\pi)-n+\\sum_{i=1}^n \\dist_T(i,\\pi(i))},$$ where $c(\\pi)$ denotes the number of cycles in $\\pi$, and $\\dist_T$ is the distance function in $T$. In this work, we assess the sharpness and strictness of this upper bound. We show that the upper bound is exact for all trees of maximum diameter and also for all trees of minimum diameter, and we exhibit some families of trees (that are non-extremal) for which the bound is strict. We then show that for every $n$, there exists a tree on $n$ vertices, suc...

  19. AP diameter shows the strongest correlation with CTDI and DLP in abdominal and chest CT.

    LENUS (Irish Health Repository)

    Zarb, Francis

    2010-01-01

    The purpose of this study is to investigate the relationships among cross-sectional diameters, weight and computed tomography (CT) dose descriptors (CTDI and DLP) to identify which is best used as a measure for the establishment of DRLs in CT. Data (gender, weight, cross-sectional diameters, dose descriptors) from 56 adult patients attending for either a CT examination of the abdomen or chest was obtained from two spiral CT units using automatic milliampere modulation. The AP diameter was demonstrated as the main contributing factor influencing the dose in CT (CTDI: r(2) = 0.269, p-value < or =0.001; DLP: r(2) = 0.260, p-value < or =0.001) since it has a greater correlation with radiation dose than body weight and can thus be its substitute in dose-reduction strategies and establishment of DRLs. The advantages of using the AP diameter are that it can easily be measured prior to scanning or retrospectively from previous CT images. However, further studies on the practicality of this approach are recommended.

  20. Retinal hemodynamic oxygen reactivity assessed by perfusion velocity, blood oximetry and vessel diameter measurements

    DEFF Research Database (Denmark)

    Klefter, Oliver Niels; Lauritsen, Anne Øberg; Larsen, Michael

    2015-01-01

    PURPOSE: To test the oxygen reactivity of a fundus photographic method of measuring macular perfusion velocity and to integrate macular perfusion velocities with measurements of retinal vessel diameters and blood oxygen saturation. METHODS: Sixteen eyes in 16 healthy volunteers were studied at two...... measurements may provide comprehensive information about retinal metabolism....