WorldWideScience

Sample records for two-meter diameter jp-8

  1. Conversion of a micro, glow-ignition, two-stroke engine from nitromethane-methanol blend fuel to military jet propellant (JP-8)

    Science.gov (United States)

    Wiegand, Andrew L.

    The goal of the thesis "Conversion of a Micro, Glow-Ignition, Two-Stroke Engine from Nitromethane-Methanol Blend Fuel to Military Jet Propellant (JP-8)" was to demonstrate the ability to operate a small engine on JP-8 and was completed in two phases. The first phase included choosing, developing a test stand for, and baseline testing a nitromethane-methanol-fueled engine. The chosen engine was an 11.5 cc, glow-ignition, two-stroke engine designed for remote-controlled helicopters. A micro engine test stand was developed to load and motor the engine. Instrumentation specific to the low flow rates and high speeds of the micro engine was developed and used to document engine behavior. The second phase included converting the engine to operate on JP-8, completing JP-8-fueled steady-state testing, and comparing the performance of the JP-8-fueled engine to the nitromethane-methanol-fueled engine. The conversion was accomplished through a novel crankcase heating method; by heating the crankcase for an extended period of time, a flammable fuel-air mixture was generated in the crankcase scavenged engine, which greatly improved starting times. To aid in starting and steady-state operation, yttrium-zirconia impregnated resin (i.e. ceramic coating) was applied to the combustion surfaces. This also improved the starting times of the JP-8-fueled engine and ultimately allowed for a 34-second starting time. Finally, the steady-state data from both the nitromethane-methanol and JP-8-fueled micro engine were compared. The JP-8-fueled engine showed signs of increased engine friction while having higher indicated fuel conversion efficiency and a higher overall system efficiency. The minimal ability of JP-8 to cool the engine via evaporative effects, however, created the necessity of increased cooling air flow. The conclusion reached was that JP-8-fueled micro engines could be viable in application, but not without additional research being conducted on combustion phenomenon and

  2. Autoignition and Combustion of Diesel and JP-8

    National Research Council Canada - National Science Library

    Seshadri, Kalyanasundaram

    2007-01-01

    ...: JP-8, commercial jet fuel (with additive package), or commercial jet fuel (without additives)." The objective of the proposed research is to understand those key aspects of combustion of JP-8 that are required to facilitate this conversion...

  3. Evaluation of gene expression profile of keratinocytes in response to JP-8 jet fuel

    International Nuclear Information System (INIS)

    Espinoza, Luis A.; Li Peijun; Lee, Richard Y.; Wang Yue; Boulares, A. Hamid; Clarke, Robert; Smulson, Mark E.

    2004-01-01

    The skin is the principal barrier against any environmental insult. Therefore, there is a high risk for a large number of military and civilian personnel exposed to jet fuel JP-8 to suffer percutaneous absorption of this fuel. This paper reports the use of cDNA microarray to identify the gene expression profile in normal human epidermal keratinocytes exposed to JP-8 for 24-h and 7-day periods. The effects of JP-8 exposure on keratinocytes at these two different periods induced a set of genes with altered expression in response to this type of insult. Microarray data were visualized using a novel algorithm based on simple statistical analyses to reduce data dimensionality and identify subsets of discriminant genes. Predictive neural networks were built using a multiplayer perceptron to carry out a proper classification task in microarray data in the untreated versus JP-8-treated samples. The pattern of expressions in response to JP-8 provides evidences that detoxificant-related and cell growth regulator genes with the most variability in the level of expression may be useful genetic markers in adverse health effects of personnel exposed to JP-8. The approaches in our analysis provide a simple, safe, novel, and effective method that is reliable in identifying and analyzing gene expression in samples treated with JP-8 or over potential toxic agents. Gene expression data from these studies can be used to build accurate predictive models that separate different molecular profiles. The data establish the use and effectiveness of these approaches for future prospective studies

  4. Effects of JP-8 Jet Fuel on Homeostasis of Clone 9 Rat Liver Cells

    Science.gov (United States)

    Wilson, C. L.; Barhoumi, R.; Burghardt, R.; Miladi, A.; Jung, A.

    2000-01-01

    Chronic exposure to JP-8 and other kerosene-based petroleum distillates has been associated with hepatic, renal, neurologic, pulmonary, and immune toxicity. However, the effects of kerosene-type jet fuels on cellular homeostasis hitherto have not been reported. Fluorescence imaging using a Meridian Ultima laser scanning fluorescence microscope was used to evaluate the effect of JP-8 jet fuel on a communication competent rat liver cell line. Several endpoints of cellular function were measured including gap junctional intercellular communication (GJIC), mitochondrial and plasma membrane potential (MMP and PMP, respectively), intracellular glutathione (GSH) concentration, glutathione-S-transferase (GST) activity, and reactive oxygen species (ROS) generation. Cells were treated with JP-8 (0.01 to 2% in ethanol (EtOH)) for the following time points: 1 h, 24 h, 48 h, and analysis immediately after addition of jet fuel. GJIC analyzed directly after addition of 1% JP-8 was reduced 4.9-fold relative to EtOH-dosed control groups and further reduction (12.6-fold) was observed in cells treated for 1 h. Moreover, GJIC was not recoverable in cells treated with 1% JP-8 for 1 h and subsequently washed and incubated in fresh medium for 1 h. Significant changes in GSH content and GST activity were observed in cells analyzed directly after addition of 1% JP-8. GSH content increased in cells treated for 1 h with less than 2% JP-8 whereas treatment with 2% JP-8 for 1 h resulted in a 50% reduction in intracellular GSH relative to EtOH-dosed controls. Cells treated with 1% JP-8 for 48 h exhibited changes in GSH levels. However, higher JP-8 concentrations exhibited more pronounced changes in GSH and GST, which led to suppression of GSH synthesis. ROS increased in a dose-responsive fashion at JP-8 concentrations up to 1%, but decreased to 80% of control values at 2% and 3% JP-8. A 25% reduction in PMP was observed in cells treated for 1 h with 1% JP-8. In contrast, cells treated for 48 h

  5. Reduced Chemical Kinetic Mechanisms for JP-8 Combustion

    National Research Council Canada - National Science Library

    Montgomery, Christopher J; Cannon, S. M; Mawid, M. A; Sekar, B

    2002-01-01

    Using CARM (Computer Aided Reduction Method), a computer program that automates the mechanism reduction process, six different reduced chemical kinetic mechanisms for JP-8 combustion have been generated...

  6. Subchronic JP-8 jet fuel exposure enhances vulnerability to noise-induced hearing loss in rats.

    Science.gov (United States)

    Fechter, L D; Fisher, J W; Chapman, G D; Mokashi, V P; Ortiz, P A; Reboulet, J E; Stubbs, J E; Lear, A M; McInturf, S M; Prues, S L; Gearhart, C A; Fulton, S; Mattie, D R

    2012-01-01

    Both laboratory and epidemiological studies published over the past two decades have identified the risk of excess hearing loss when specific chemical contaminants are present along with noise. The objective of this study was to evaluate the potency of JP-8 jet fuel to enhance noise-induced hearing loss (NIHL) using inhalation exposure to fuel and simultaneous exposure to either continuous or intermittent noise exposure over a 4-wk exposure period using both male and female Fischer 344 rats. In the initial study, male (n = 5) and female (n = 5) rats received inhalation exposure to JP-8 fuel for 6 h/d, 5 d/wk for 4 wk at concentrations of 200, 750, or 1500 mg/m³. Parallel groups of rats also received nondamaging noise (constant octave band noise at 85 dB(lin)) in combination with the fuel, noise alone (75, 85, or 95 dB), or no exposure to fuel or noise. Significant concentration-related impairment of auditory function measured by distortion product otoacoustic emissions (DPOAE) and compound action potential (CAP) threshold was seen in rats exposed to combined JP-8 plus noise exposure when JP-8 levels of 1500 mg/m³ were presented with trends toward impairment seen with 750 mg/m³ JP-8 + noise. JP-8 alone exerted no significant effect on auditory function. In addition, noise was able to disrupt the DPOAE and increase auditory thresholds only when noise exposure was at 95 dB. In a subsequent study, male (n = 5 per group) and female (n = 5 per group) rats received 1000 mg/m³ JP-8 for 6 h/d, 5 d/wk for 4 wk with and without exposure to 102 dB octave band noise that was present for 15 min out of each hour (total noise duration 90 min). Comparisons were made to rats receiving only noise, and thosereceiving no experimental treatment. Significant impairment of auditory thresholds especially for high-frequency tones was identified in the male rats receiving combined treatment. This study provides a basis for estimating excessive hearing loss under

  7. Age-related differences in pulmonary inflammatory responses to JP-8 jet fuel aerosol inhalation.

    Science.gov (United States)

    Wang, S; Young, R S; Witten, M L

    2001-02-01

    Our previous studies have demonstrated that JP-8 jet fuel aerosol inhalation induced lung injury and dysfunction. To further examine JP-8 jet fuel-induced inflammatory mechanisms, a total of 40 male C57BL/6 mice (young, 3.5 months; adult, 12 months; half in each age group) were randomly assigned to the exposure or control groups. Mice were nose-only exposed to room air or atmospheres of 1000 mg/m3 JP-8 jet fuel for 1 h/day for 7 days. Lung injury was assessed by pulmonary mechanics, respiratory permeability, lavaged cell profile, and chemical mediators in bronchoalveolar lavage fluid (BALF). The young and adult mice exposed to JP-8 jet fuel had similar values with regards to increased lung dynamic compliance, lung permeability, BALF cell count, and decreased PGE2. However, there were several different responses between the young-versus-adult mice with respect to BALF cell differential, TNF-alpha, and 8-iso-PGF2,, levels after exposure to JP-8 jet fuel. These data suggest that JP-8 jet fuel may have different inflammatory mechanisms leading to lung injury and dysfunction in the younger-versus-adult mice.

  8. JP-8 jet fuel can promote auditory impairment resulting from subsequent noise exposure in rats.

    Science.gov (United States)

    Fechter, Laurence D; Gearhart, Caroline; Fulton, Sherry; Campbell, Jerry; Fisher, Jeffrey; Na, Kwangsam; Cocker, David; Nelson-Miller, Alisa; Moon, Patrick; Pouyatos, Benoit

    2007-08-01

    We report on the transient and persistent effects of JP-8 jet fuel exposure on auditory function in rats. JP-8 has become the standard jet fuel utilized in the United States and North Atlantic Treaty Organization countries for military use and it is closely related to Jet A fuel, which is used in U.S. domestic aviation. Rats received JP-8 fuel (1000 mg/m(3)) by nose-only inhalation for 4 h and half of them were immediately subjected to an octave band of noise ranging between 97 and 105 dB in different experiments. The noise by itself produces a small, but permanent auditory impairment. The current permissible exposure level for JP-8 is 350 mg/m(3). Additionally, a positive control group received only noise exposure, and a fourth group consisted of untreated control subjects. Exposures occurred either on 1 day or repeatedly on 5 successive days. Impairments in auditory function were assessed using distortion product otoacoustic emissions and compound action potential testing. In other rats, tissues were harvested following JP-8 exposure for assessment of hydrocarbon levels or glutathione (GSH) levels. A single JP-8 exposure by itself at 1000 mg/m(3) did not disrupt auditory function. However, exposure to JP-8 and noise produced an additive disruption in outer hair cell function. Repeated 5-day JP-8 exposure at 1000 mg/m(3) for 4 h produced impairment of outer hair cell function that was most evident at the first postexposure assessment time. Partial though not complete recovery was observed over a 4-week postexposure period. The adverse effects of repeated JP-8 exposures on auditory function were inconsistent, but combined treatment with JP-8 + noise yielded greater impairment of auditory function, and hair cell loss than did noise by itself. Qualitative comparison of outer hair cell loss suggests an increase in outer hair cell death among rats treated with JP-8 + noise for 5 days as compared to noise alone. In most instances, hydrocarbon constituents of the fuel

  9. Comparative electrophysiological evaluation of hippocampal function following repeated inhalation exposures to JP-8, Jet A, JP-5, and the synthetic Fischer Tropsch fuel.

    Science.gov (United States)

    Rohan, Joyce G; McInturf, Shawn M; Miklasevich, Molly K; Gut, Chester P; Grimm, Michael D; Reboulet, James E; Howard, William R; Mumy, Karen L

    2018-01-01

    Exposure to fuels continues to be a concern in both military and general populations. The aim of this study was to examine effects of in vivo rat repeated exposures to different types of jet fuel utilizing microelectrode arrays for comparative electrophysiological (EP) measurements in hippocampal slices. Animals were exposed to increasing concentrations of four jet fuels, Jet Propellant (JP)-8, Jet A, JP-5, or synthetic Fischer Tropsch (FT) fuel via whole-body inhalation for 20 d (6 hr/d, 5 d/week for 28 d) and synaptic transmission as well as behavioral performance were assessed. Our behavioral studies indicated no significant changes in behavioral performance in animals exposed to JP-8, Jet A, or JP-5. A significant deviation in learning pattern during the Morris water maze task was observed in rats exposed to the highest concentration of FT (2000 mg/m 3 ). There were also significant differences in the EP profile of hippocampal neurons from animals exposed to JP-8, Jet A, JP-5, or FT compared to control air. However, these differences were not consistent across fuels or dose dependent. As expected, patterns of EP alterations in brain slices from JP-8 and Jet A exposures were more similar compared to those from JP-5 and FT. Further longitudinal investigations are needed to determine if these EP effects are transient or persistent. Such studies may dictate if and how one may use EP measurements to indicate potential susceptibility to neurological impairments, particularly those that result from inhalation exposure to chemicals or mixtures.

  10. Systemic molecular and cellular changes induced in rats upon inhalation of JP-8 petroleum fuel vapor.

    Science.gov (United States)

    Hanas, Jay S; Bruce Briggs, G; Lerner, Megan R; Lightfoot, Stan A; Larabee, Jason L; Karsies, Todd J; Epstein, Robert B; Hanas, Rushie J; Brackett, Daniel J; Hocker, James R

    2010-05-01

    Limited information is available regarding systemic changes in mammals associated with exposures to petroleum/hydrocarbon fuels. In this study, systemic toxicity of JP-8 jet fuel was observed in a rat inhalation model at different JP-8 fuel vapor concentrations (250, 500, or 1000 mg/m(3), for 91 days). Gel electrophoresis and mass spectrometry sequencing identified the alpha-2 microglobulin protein to be elevated in rat kidney in a JP-8 dose-dependent manner. Western blot analysis of kidney and lung tissue extracts revealed JP-8 dependent elevation of inducible heat shock protein 70 (HSP70). Tissue changes were observed histologically (hematoxylin and eosin staining) in liver, kidney, lung, bone marrow, and heart, and more prevalently at medium or high JP-8 vapor phase exposures (500-1000 mg/m(3)) than at low vapor phase exposure (250 mg/m(3)) or non-JP-8 controls. JP-8 fuel-induced liver alterations included dilated sinusoids, cytoplasmic clumping, and fat cell deposition. Changes to the kidneys included reduced numbers of nuclei, and cytoplasmic dumping in the lumen of proximal convoluted tubules. JP-8 dependent lung alterations were edema and dilated alveolar capillaries, which allowed clumping of red blood cells (RBCs). Changes in the bone marrow in response to JP-8 included reduction of fat cells and fat globules, and cellular proliferation (RBCs, white blood cells-WBCs, and megakaryocytes). Heart tissue from JP-8 exposed animals contained increased numbers of inflammatory and fibroblast cells, as well as myofibril scarring. cDNA array analysis of heart tissue revealed a JP-8 dependent increase in atrial natriuretic peptide precursor mRNA and a decrease in voltage-gated potassium (K+) ion channel mRNA.

  11. Inhalation exposure to jet fuel (JP8) among U.S. Air Force personnel.

    Science.gov (United States)

    Smith, Kristen W; Proctor, Susan P; Ozonoff, Al; McClean, Michael D

    2010-10-01

    As jet fuel is a common occupational exposure among military and civilian populations, this study was conducted to characterize jet fuel (JP8) exposure among active duty U.S. Air Force personnel. Personnel (n = 24) were divided a priori into high, moderate, and low exposure groups. Questionnaires and personal air samples (breathing zone) were collected from each worker over 3 consecutive days (72 worker-days) and analyzed for total hydrocarbons (THC), benzene, toluene, ethylbenzene, xylenes, and naphthalene. Air samples were collected from inside the fuel tank and analyzed for the same analytes. Linear mixed-effects models were used to evaluate the exposure data. Our results show that the correlation of THC (a measure of overall JP8 inhalation exposure) with all other analytes was moderate to strong in the a priori high and moderate exposure groups combined. Inhalation exposure to all analytes varied significantly by self-reported JP8 exposure (THC levels higher among workers reporting JP8 exposure), a priori exposure group (THC levels in high group > moderate group > low group), and more specific job task groupings (THC levels among workers in fuel systems hangar group > refueling maintenance group > fuel systems office group > fuel handling group > clinic group), with task groupings explaining the most between-worker variability. Among highly exposed workers, statistically significant job task-related predictors of inhalation exposure to THC indicated that increased time in the hangar, working close to the fuel tank (inside > less than 25 ft > greater than 25 ft), primary job (entrant > attendant/runner/fireguard > outside hangar), and performing various tasks near the fuel tank, such as searching for a leak, resulted in higher JP8 exposure. This study shows that while a priori exposure groups were useful in distinguishing JP8 exposure levels, job task-based categories should be considered in epidemiologic study designs to improve exposure classification. Finally

  12. Ototoxic potential of JP-8 and a Fischer-Tropsch synthetic jet fuel following subacute inhalation exposure in rats.

    Science.gov (United States)

    Fechter, Laurence D; Gearhart, Caroline A; Fulton, Sherry

    2010-07-01

    This study was undertaken to identify the ototoxic potential of two jet fuels presented alone and in combination with noise. Rats were exposed via a subacute inhalation paradigm to JP-8 jet fuel, a kerosene-based fuel refined from petroleum, and a synthetic fuel produced by the Fischer-Tropsch (FT) process. Although JP-8 contains small ( approximately 5%) concentrations of aromatic hydrocarbons some of which known to be ototoxic, the synthetic fuel does not. The objectives of this study were to identify a lowest observed adverse effect level and a no observed adverse effect level for each jet fuel and to provide some preliminary, but admittedly, indirect evidence concerning the possible role of the aromatic hydrocarbon component of petroleum-based jet fuel on hearing. Rats (n = 5-19) received inhalation exposure to JP-8 or to FT fuel for 4 h/day on five consecutive days at doses of 500, 1000, and 2000 mg/m(3). Additional groups were exposed to various fuel concentrations followed by 1 h of an octave band of noise, noise alone, or no exposure to fuel or noise. Significant dose-related impairment in the distortion product otoacoustic emissions (DPOAE) was seen in subjects exposed to combined JP-8 plus noise exposure when JP-8 levels of at least 1000 mg/m(3) were presented. No noticeable impairment was observed at JP-8 levels of 500 mg/m(3) + noise. In contrast to the effects of JP-8 on noise-induced hearing loss, FT exposure had no effect by itself or in combination with noise exposure even at the highest exposure level tested. Despite an observed loss in DPOAE amplitude seen only when JP-8 and noise were combined, there was no loss in auditory threshold or increase in hair cell loss in any exposure group.

  13. Intrinsic remediation of JP-4 fuel in soil and ground water

    International Nuclear Information System (INIS)

    Schmithorst, W.L. Jr.; Vardy, J.A.

    1995-01-01

    Intrinsic remediation methods were employed to remediate soil and ground water contaminated by JP-4 fuel at the United States Coast Guard (USCG) Support Center facility in Elizabeth City, North Carolina. By the time the release was discovered, non-aqueous phase JP-4 fuel was detected in ground water over an area of approximately 8,000 square feet. In addition, concentrations of dissolved BTEX in ground water exceeded 5,000 microg/L. Tight clays present in the upper two meters of the aquifer, underlain by highly transmissive sands, prevented remediation of the JP-4 by conventional treatment methods. Therefore, a system of air injection and air extraction wells were installed that simultaneously depressed the water table and extracted hydrocarbon vapors. The conceptual idea, developed by the EPA RS Kerr Environmental Laboratory (RSKERL) in Ada, Oklahoma, is to stimulate rapid intrinsic biodegradation of the JP-4 fuel compounds. Subsequent biorespiration measurements indicated that the fuel compounds were being rapidly biodegraded. Upon removal of the non aqueous JP-4 compounds, an investigation was conducted to determine if the aquifer had an adequate assimilative capacity to support natural aerobic and anaerobic biodegradation of the contaminants. Analysis of ground water samples collected using a cone penetrometer and a direct-push sampling device indicate a sufficient concentration of electron acceptors to support natural biodegradation of the JP-4 compounds

  14. The Effect of Fuel Injector Nozzle Configuration on JP-8 Sprays at Diesel Engine Conditions

    Science.gov (United States)

    2014-10-01

    The Effect of Fuel Injector Nozzle Configuration on JP-8 Sprays at Diesel Engine Conditions by Matthew Kurman, Luis Bravo, Chol-Bum Kweon...Fuel Injector Nozzle Configuration on JP-8 Sprays at Diesel Engine Conditions Matthew Kurman, Luis Bravo, and Chol-Bum Kweon Vehicle Technology...March 2014 4. TITLE AND SUBTITLE The Effect of Fuel Injector Nozzle Configuration on JP-8 Sprays at Diesel Engine Conditions 5a. CONTRACT NUMBER 5b

  15. Toxicokinetic Study for Investigation of Sex Differences in Internal Dosimetry of Jet Propulsion Fuel 8 (JP-8) in the Laboratory Rat

    Science.gov (United States)

    2013-07-26

    brain and observed cochlea concentrations of n-octane, n-decane, n-tetradecane, ethylbenzene , m-xylene and toluene in rats exposed to JP-8 (high...occur in combination with noise expo- sures (Department of the Army, 1998). The hydrocarbons ethylbenzene , toluene, and p-xylene, known to be present in...to supply JP-8 to the Cannon nose-only exposure system. Rats were exposed to JP-8 on a 52-position Cannon nose-only exposure system (Lab Products

  16. CYTOGENETIC STUDIES IN MICE TREATED WITH THE JET FUELS, JET-A AND JP-8

    Science.gov (United States)

    Cytogenetic studies in mice treated with the jet fuels, Jet-A and JP-8AbstractThe genotoxic potential of the jet fuels, Jet-A and JP-8, were examined in mice treated on the skin with a single dose of 240 ug/mouse. Peripheral blood smears were prepared at the start of the ...

  17. Combustion of High Molecular Weight Hydrocarbon Fuels and JP-8 at Moderate Pressures

    Science.gov (United States)

    2016-07-26

    1. Introduction Fundamental knowledge of mechanisms of autoignition of condensed hydrocarbon fuels at elevated pressures is essential for accurate...particular JP-8) and surrogates of jet-fuels in laminar non-uniform flows at elevated pressures upto 2.5 MPa. Experimental and kinetic modeling studies...AGENCY NAME(S) AND ADDRESS (ES) U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 Combustion, Jet Fuels, JP-8, Elevated

  18. Inhalation Exposure to Jet Fuel (JP8) Among U.S. Air Force Personnel

    Science.gov (United States)

    2010-10-01

    are occupationally exposcd.(I) )nfonnation on the health consequences o f human exposure 10 JP8 is limited.(I·2) though there is some evidence that...JP8 may be toxic to the immune system. respirdtory trdCt, and nervous system at exposure concentrations ncar 350 mg/m·1.m The current ACG lH...Egeghy et al.(7) and to reflect a scheme that may be used in epidemiologic studies assessing exposure and hcalth outcomes . The high exposure group

  19. 1.8. Brand*, HA Badenhorst, FK 8iebrits and EH Kemm JP Hayes et ...

    African Journals Online (AJOL)

    Brand*, H.A. Badenhorst, F.K. 8iebrits and E.H. Kemm. Animal and Dairy Science Research Institute, Private Bag X2, Irene 1675, Republic of South Africa. J.P. Hayes. Department of Poultry Science, University of Stellenbosch, Stellenbosch 7600, Republic of South Africa. The experiment was conducted to compare the ...

  20. Turbine flow meter response in two-phase flows

    International Nuclear Information System (INIS)

    Shim, W.J.; Dougherty, T.J.; Cheh, H.Y.

    1996-01-01

    The purpose of this paper is to suggest a simple method of calibrating turbine flow meters to measure the flow rates of each phase in a two-phase flow. The response of two 50.8 mm (2 inch) turbine flow meters to air-water, two-phase mixtures flowing vertically in a 57 mm I.D. (2.25 inch) polycarbonate tube has been investigated for both upflow and downflow. The flow meters were connected in series with an intervening valve to provide an adjustable pressure difference between them. Void fractions were measured by two gamma densitometers, one upstream of the flow meters and the other downstream. The output signal of the turbine flow meters was found to depend only on the actual volumetric flow rate of the gas, F G , and liquid, F L , at the location of the flow meter

  1. Effects of aerosol-vapor JP-8 jet fuel on the functional observational battery, and learning and memory in the rat.

    Science.gov (United States)

    Baldwin, C M; Houston, F P; Podgornik, M N; Young, R S; Barnes, C A; Witten, M L

    2001-01-01

    To determine whether JP-8 jet fuel affects parameters of the Functional Observational Battery (FOB), visual discrimination, or spatial learning and memory, the authors exposed groups of male Fischer Brown Norway hybrid rats for 28 d to aerosol/vapor-delivered JP-8, or to JP-8 followed by 15 min of aerosolized substance P analogue, or to sham-confined fresh room air. Behavioral testing was accomplished with the U.S. Environmental Protection Agency's Functional Observational Battery. The authors used the Morris swim task to test visual and spatial learning and memory testing. The spatial test included examination of memory for the original target location following 15 d of JP-8 exposure, as well as a 3-d new target location learning paradigm implemented the day that followed the final day of exposure. Only JP-8 exposed animals had significant weight loss by the 2nd week of exposure compared with JP-8 with substance P and control rats; this finding compares with those of prior studies of JP-8 jet fuel. Rats exposed to JP-8 with or without substance P exhibited significantly greater rearing and less grooming behavior over time than did controls during Functional Observational Battery open-field testing. Exposed rats also swam significantly faster than controls during the new target location training and testing, thus supporting the increased activity noted during Functional Observational Battery testing. There were no significant differences between the exposed and control groups' performances during acquisition, retention, or learning of the new platform location in either the visual discrimination or spatial version of the Morris swim task. The data suggest that although visual discrimination and spatial learning and memory were not disrupted by JP-8 exposure, arousal indices and activity measures were distinctly different in these animals.

  2. The Gemini 8-Meter Telescopes Project

    Science.gov (United States)

    Boroson, Todd A.

    1995-05-01

    The Gemini 8-Meter Telescopes Project is an international partnership to build and operate two 8-meter telescopes, one on Mauna Kea, Hawaii, and one on Cerro Pachon, Chile. The telescopes will be international facilities, open to the scientific communities of the six member countries, the United States (50%), the United Kingdom (25%), Canada (15%), Chile (5%), Argentina (2.5%), and Brazil (2.5%). The telescopes are designed to exploit the best atmospheric conditions at these excellent sites. Near diffraction limited performance will be delivered at 2.2 microns and longward, with minimal degradation of the best seeing conditions at shorter wavelengths. The telescopes and facilities are designed to achieve emissivity opportunity. First light for the Mauna Kea telescope is expected in late 1998, and for the Cerro Pachon telescope in mid-2000. This talk will report on construction progress, the instrumental capabilities, and operations strategies being considered. The Gemini 8-meter Telescopes Project is managed by the Association of Universities for Research in Astronomy (AURA), Inc. under a cooperative agreement with the National Science Foundation which serves as executive agency for the Gemini partner countries. U.S. participation in the project is through the U.S. Gemini Program, a division of the National Optical Astronomy Observatories. NOAO is operated by AURA, Inc. under cooperative agreement with the National Science Foundation.

  3. Dermal Exposure to Jet Fuel JP-8 Significantly Contributes to the Production of Urinary Naphthols in Fuel-Cell Maintenance Workers

    OpenAIRE

    Chao, Yi-Chun E.; Kupper, Lawrence L.; Serdar, Berrin; Egeghy, Peter P.; Rappaport, Stephen M.; Nylander-French, Leena A.

    2005-01-01

    Jet propulsion fuel 8 (JP-8) is the major jet fuel used worldwide and has been recognized as a major source of chemical exposure, both inhalation and dermal, for fuel-cell maintenance workers. We investigated the contributions of dermal and inhalation exposure to JP-8 to the total body dose of U.S. Air Force fuel-cell maintenance workers using naphthalene as a surrogate for JP-8 exposure. Dermal, breathing zone, and exhaled breath measurements of naphthalene were obtained using tape-strip sam...

  4. Assembly of 5.5-Meter Diameter Developmental Barrel Segments for the Ares I Upper Stage

    Science.gov (United States)

    Carter, Robert W.

    2011-01-01

    Full scale assembly welding of Ares I Upper Stage 5.5-Meter diameter cryogenic tank barrel segments has been performed at the Marshall Space Flight Center (MSFC). One full-scale developmental article produced under the Ares 1 Upper Stage project is the Manufacturing Demonstration Article (MDA) Barrel. This presentation will focus on the welded assembly of this barrel section, and associated lessons learned. Among the MDA articles planned on the Ares 1 Program, the Barrel was the first to be completed, primarily because the process of manufacture from piece parts (barrel panels) utilized the most mature friction stir process planned for use on the Ares US program: Conventional fixed pin Friction Stir Welding (FSW). This process is in use on other space launch systems, including the Shuttle s External Tank, the Delta IV common booster core, the Delta II, and the Atlas V rockets. The goals for the MDA Barrel development were several fold: 1) to prove out Marshall Space Flight Center s new Vertical Weld Tool for use in manufacture of cylindrical barrel sections, 2) to serve as a first run for weld qualification to a new weld specification, and 3) to provide a full size cylindrical section for downstream use in precision cleaning and Spray-on Foam Insulation development. The progression leading into the welding of the full size barrel included sub scale panel welding, subscale cylinder welding, a full length confidence weld, and finally, the 3 seamed MDA barrel processing. Lessons learned on this MDA program have been carried forward into the production tooling for the Ares 1 US Program, and in the use of the MSFC VWT in processing other large scale hardware, including two 8.4 meter diameter Shuttle External Tank barrel sections that are currently being used in structural analysis to validate shell buckling models.

  5. Dermal exposure to jet fuel JP-8 significantly contributes to the production of urinary naphthols in fuel-cell maintenance workers.

    Science.gov (United States)

    Chao, Yi-Chun E; Kupper, Lawrence L; Serdar, Berrin; Egeghy, Peter P; Rappaport, Stephen M; Nylander-French, Leena A

    2006-02-01

    Jet propulsion fuel 8 (JP-8) is the major jet fuel used worldwide and has been recognized as a major source of chemical exposure, both inhalation and dermal, for fuel-cell maintenance workers. We investigated the contributions of dermal and inhalation exposure to JP-8 to the total body dose of U.S. Air Force fuel-cell maintenance workers using naphthalene as a surrogate for JP-8 exposure. Dermal, breathing zone, and exhaled breath measurements of naphthalene were obtained using tape-strip sampling, passive monitoring, and glass bulbs, respectively. Levels of urinary 1- and 2-naphthols were determined in urine samples and used as biomarkers of JP-8 exposure. Multiple linear regression analyses were conducted to investigate the relative contributions of dermal and inhalation exposure to JP-8, and demographic and work-related covariates, to the levels of urinary naphthols. Our results show that both inhalation exposure and smoking significantly contributed to urinary 1-naphthol levels. The contribution of dermal exposure was significantly associated with levels of urinary 2-naphthol but not with urinary 1-naphthol among fuel-cell maintenance workers who wore supplied-air respirators. We conclude that dermal exposure to JP-8 significantly contributes to the systemic dose and affects the levels of urinary naphthalene metabolites. Future work on dermal xenobiotic metabolism and toxicokinetic studies are warranted in order to gain additional knowledge on naphthalene metabolism in the skin and the contribution to systemic exposure.

  6. A Demonstration of HEFA SPK/JP-8 Fuel Blend at the Camp Grayling Joint Maneuver Training Center

    Science.gov (United States)

    2012-10-01

    Interim Report TFLRF No. 400 Evaluation of the Fuel Effects of Synthetic JP-8 Blends on the 6.5L Turbo Diesel V8 from General Engine Products (GEP) Using...on the biofuel did indicate they noticed some differences in comparison to the diesel fuel they normally use. These differences were expected since...the biofuel blend is a drop-in replacement for JP-8 (jet) fuel rather than diesel fuel. Military Impact The U.S. Military will be prepared to

  7. Alternative Bio-Derived JP-8 Class Fuel and JP-8 Fuel: Flame Tube Combustor Test Results Compared using a GE TAPS Injector Configuration

    Science.gov (United States)

    Hicks, Yolanda R.; Anderson, Robert; Tedder, Sarah

    2016-01-01

    This paper presents results from tests in a NASA Glenn Research Center (GRC) flame tube facility, where a bio-derived alternate fuel was compared with JP-8 for emissions and general combustion performance. A research version of General Electric Aviation (GE) TAPS injector was used for the tests. Results include 2D, planar laser-based imaging as well as basic flow visualization of the flame. Four conditions were selected that simulate various engine power conditions relevant to NASA Fundamental Aeronautics Supersonics and Environmentally Responsible Aviation Projects were tested.

  8. A Study of Spill Control Characteristics of JP-8 and Conventional Diesel Fuel with a Common Rail Direct Injection System

    Directory of Open Access Journals (Sweden)

    Seomoon Yang

    2017-12-01

    Full Text Available Diversification of energy sources is a key task for decreasing environmental impacts and global emission of gases. JP-8, a fuel derived from natural gas, coal, biomass, and waste plastics, is a bright prospect. JP-8 is considered a multi-source multi-purpose fuel, with several applications. A preliminary characterization of the JP-8 injection rate and injection quantity behavior was investigated based on the high-pressure common rail injection system used in a heavy-duty engine. According to the spill injection and injection pressure, a trade-off trend between injection rate and injection quantity was observed. As expected, pilot injection of JP-8 aviation fuel and diesel fuel affects the spray quantity and injection evolution of the subsequent operation without pilot injection. The difference in spilling between diesel and JP-8 aviation fuel is greater than the difference in injection amount per time; in the process of controlling the injector solenoid through ECU (Electric Control Units, the oil pressure valve and the needle valve operate to a higher extent in order to maintain the diesel fuel’s injection quantity volume. It was found that the total injection quantity was decreased by adding 20% pilot injection duration. Because the pilot injection quantity causes solenoid response, loss and needle lift stroke friction loss.

  9. Comparing a Fischer-Tropsch Alternate Fuel to JP-8 and Their 50-50 Blend: Flow and Flame Visualization Results

    Science.gov (United States)

    Hicks, Yolanda R.; Tacina, M.

    2013-01-01

    Combustion performance of a Fischer-Tropsch (FT) jet fuel manufactured by Sasol was compared to JP-8 and a 50-50 blend of the two fuels, using the NASA/Woodward 9 point Lean Direct Injector (LDI) in its baseline configuration. The baseline LDI configuration uses 60deg axial air-swirlers, whose vanes generate clockwise swirl, in the streamwise sense. For all cases, the fuel-air equivalence ratio was 0.455, and the combustor inlet pressure and pressure drop were 10-bar and 4 percent. The three inlet temperatures used were 828, 728, and 617 K. The objectives of this experiment were to visually compare JP-8 flames with FT flames for gross features. Specifically, we sought to ascertain in a simple way visible luminosity, sooting, and primary flame length of the FT compared to a standard JP grade fuel. We used color video imaging and high-speed imaging to achieve these goals. The flame color provided a way to qualitatively compare soot formation. The length of the luminous signal measured using the high speed camera allowed an assessment of primary flame length. It was determined that the shortest flames resulted from the FT fuel.

  10. Lagrangian Modeling of Evaporating Sprays at Diesel Engine Conditions: Effects of Multi-Hole Injector Nozzles With JP-8 Surrogates

    Science.gov (United States)

    2014-05-01

    Lagrangian Modeling of Evaporating Sprays at Diesel Engine Conditions: Effects of Multi-Hole Injector Nozzles With JP-8 Surrogates by L...efficiency. In this study, three-dimensional numerical simulations of single and two-hole injector nozzles under diesel conditions are conducted to...numerical simulations of single and two-hole injector nozzles under diesel conditions are conducted to study the spray behavior and the effect of

  11. Construction and testing of the two meter diameter TPC thin superconducting solenoid

    International Nuclear Information System (INIS)

    Green, M.A.; Eberhard, P.H.; Ross, R.R.; Taylor, J.D.

    1979-08-01

    High energy colliding beam physics often requires large detectors which contain large volumes of magnetic field. The TPC (Time Projection Chamber) experiment at PEP will use a 1.5T magnetic field within a cylindrical volume which is 2.04m in diameter bounded by iron poles which are separated by a gap of 3.25m. The TPC magnet, built in 1979 by the Lawrence Berkeley Laboratory (LBL), is the largest high current density superconducting magnet built to date. It is designed to operate at a current density of 7 x 10 8 Am -2 and a stored energy of 11MJ, and it is protected by shorted secondary windings during a quench. The paper describes the basic parameters of the TPC magnet and the results of the first subassembly tests at LBL

  12. Planar measurements of soot volume fraction and OH in a JP-8 pool fire

    Energy Technology Data Exchange (ETDEWEB)

    Henriksen, Tara L.; Ring, Terry A.; Eddings, Eric G. [Department of Chemical Engineering, University of Utah, Salt Lake City, UT 84112 (United States); Nathan, Graham J. [School of Mechanical Engineering, University of Adelaide, SA 5005 (Australia); Alwahabi, Zeyad T.; Qamar, Nader [School of Chemical Engineering, University of Adelaide, SA 5005 (Australia)

    2009-07-15

    The simultaneous measurement of soot volume fraction by laser induced incandescence (LII) and qualitative imaging of OH by laser induced fluorescence (LIF) was performed in a JP-8 pool fire contained in a 152 mm diameter pan. Line of sight extinction was used to calibrate the LII system in a laminar flame, and to provide an independent method of measuring average soot volume fraction in the turbulent flame. The presence of soot in the turbulent flame was found to be approximately 50% probable, resulting in high levels of optical extinction, which increased slightly through the flame from approximately 30% near the base, to approximately 50% at the tip. This high soot loading pushes both techniques toward their detection limit. Nevertheless, useful accuracy was obtained, with the LII measurement of apparent extinction in the turbulent flame being approximately 21% lower than a direct measurement, consistent with the influence of signal trapping. The axial and radial distributions of soot volume fraction are presented, along with PDFs of volume fraction, and new insight into the behavior of soot sheets in pool fires are sought from the simultaneous measurements of OH and LII. (author)

  13. Development of thermal stability additive packages for JP-8

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, S.D.; Harrison, W.E. III; Edwards, T.; Morris, R.W.; Shouse, D.T. [USAF Wright Lab., Wright-Paterson AFB, OH (United States)

    1995-05-01

    Advanced military aircraft use fuel as the primary heat sink to cool engine and airframe components. As the fuel is thermally stressed, thermal oxidative reactions take place that result in the formation of deposits. These deposits degrade aircraft performance and ultimately lead to premature servicing of the affected components. The frequency of these incidents, coupled with the projected cooling requirements for future systems, demonstrates that current thermal stability limits are inadequate. In response to this situation, the United States Air Force (USAF) has embarked on a program to improve thermal stability using specially formulated additive packages. Results indicate that additives offer significant thermal stability improvement. This paper describes the USAF program to develop and deploy an improved JP-8 for fleet-wide use by 1998.

  14. Reactor Power Meter type SG-8

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W

    1981-01-01

    The report describes the principle and electronic circuits of the Reactor Power Meter type SG-8. The gamma radiation caused by the activity of the reactor first cooling circuit affectes the ionization chamber being the detector of the instrument. The output detector signal direct current is converted into the frequency of electric pulses by means of the current-to-frequency converter. The output converter frequency is measured by the digital frequency meter: the number of measured digits in time unit is proportional to the reactor power.

  15. GEP 6.5LT Engine Cetane Window Evaluation for ATJ/JP-8 Fuel Blends

    Science.gov (United States)

    2015-09-01

    matching pre- calibrated amplifier • BEI Shaft Encoder (0.2 CAD) • Wolff Instrumented Injector for needle lift The high speed data was recorded and post...14. ABSTRACT The European Stationary Cycle 13 Mode test and a power curve was performed on a 6.5L turbocharged V-8 diesel engine for three ATJ...15. SUBJECT TERMS ATJ, Alcohol to Jet, Cetane Number, Synthetic Fuel, JP-8, diesel engine, combustion 16. SECURITY CLASSIFICATION OF: 17

  16. Quantitative discrimination of Aggregatibacter actinomycetemcomitans highly leukotoxic JP2 clone from non-JP2 clones in diagnosis of aggressive periodontitis.

    Science.gov (United States)

    Yoshida, Akihiro; Ennibi, Oum-Keltoum; Miyazaki, Hideo; Hoshino, Tomonori; Hayashida, Hideaki; Nishihara, Tatsuji; Awano, Shuji; Ansai, Toshihiro

    2012-10-11

    Aggregatibacter actinomycetemcomitans is the etiological agent of periodontitis, and there is a strong association between clone JP2 and aggressive periodontitis in adolescents of African descent. The JP2 clone has an approximately 530-bp deletion (∆530) in the promoter region of the lkt/ltx gene, which encodes leukotoxin, and this clone has high leukotoxic activity. Therefore, this clone is very important in aggressive periodontitis. To diagnose this disease, culture methods and conventional PCR techniques are used. However, quantitative detection based on qPCR for the JP2 clone has not been developed due to genetic difficulties. In this study, we developed a qPCR-based quantification method specific to the JP2 clone. Based on our analysis of the DNA sequence of the lkt/ltx gene and its flanking region, we designed a reverse primer specific for the ∆530 deletion border sequence and developed a JP2-specific PCR-based quantification method using this primer. We also analyzed the DNA sequence of the ∆530 locus and found it to be highly conserved (97-100%) among 17 non-JP2 strains. Using the ∆530 locus, we designed a qPCR primer-probe set specific to non-JP2 clones. Next, we determined the numbers of JP2 and non-JP2 clone cells in the periodontal pockets of patients with aggressive periodontitis. The JP2-specific primers specifically amplified the genomic DNA of the A. actinomycetemcomitans JP2 clone and did not react with other bacterial DNA, whereas the non-JP2 specific primers reacted only with A. actinomycetemcomitans non-JP2 clones. Samples from the 88 periodontal sites in the 11 patients with aggressive periodontitis were analyzed. The bacterial cell numbers in 88 periodontal sites ranged from 0 to 4.8 × 10(8) (mean 1.28 × 10(7)) for JP2 clones and from 0 to 1.6 × 10(6) for non-JP2 clones (mean 1.84 × 10(5)). There were significant differences in the JP2 cell number between a clinical attachment level (CAL) ≤6 mm and a level ≥7 mm (p clones. This

  17. A two meter long straw tube prototype for the FINUDA experiment

    International Nuclear Information System (INIS)

    Benussi, L.; Bertani, M.; Bianco, S.; Fabbri, F.L.; Gianotti, P.; Giardoni, M.; Guaraldo, C.; Lanaro, A.; Lucherini, V.; Mecozzi, A.; Passamonti, L.; Russo, V.; Sarwar, S.

    1995-01-01

    A prototype using several 10mm and 20mm diameter, two meter long aluminized mylar straws has been assembled and tested with a one GeV/c pion beam. While operating with dimethyl ether space resolution, and device systematics have been studied. A simple method for measuring straw eccentricity and correcting for the corresponding systematics has been developed and, once applied, a space resolution better than 40μm can be reached. (orig.)

  18. Emissions characteristics of Military Helicopter Engines Fueled with JP-8 and a Fischer-Tropsch Fuel

    International Nuclear Information System (INIS)

    Corporan, E.; DeWitt, M.; Klingshirn, Christopher D.; Striebich, Richard; Cheng, Mengdawn

    2010-01-01

    The rapid growth in aviation activities and more stringent U.S. Environmental Protection Agency regulations have increased concerns regarding aircraft emissions, due to their harmful health and environmental impacts, especially in the vicinity of airports and military bases. In this study, the gaseous and particulate-matter emissions of two General Electric T701C engines and one T700 engine were evaluated. The T700 series engines power the U.S. Army's Black Hawk and Apache helicopters. The engines were fueled with standard military JP-8 fuel and were tested at three power settings. In addition, one of the T701C engines was operated on a natural-gas-derived Fischer-Tropsch synthetic paraffinic kerosene jet fuel. Test results show that the T701C engine emits significantly lower particulate-matter emissions than the T700 for all conditions tested. Particulate-matter mass emission indices ranged from 0.2-1.4 g/kg fuel for the T700 and 0.2-0.6 g/kg fuel for the T701C. Slightly higher NOx and lower CO emissions were observed for the T701C compared with the T700. Operation of the T701C with the Fischer-Tropsch fuel rendered dramatic reductions in soot emissions relative to operation on JP-8, due primarily to the lack of aromatic compounds in the alternative fuel. The Fischer-Tropsch fuel also produced smaller particles and slight reductions in CO emissions.

  19. Heating and Efficiency Comparison of a Fischer-Tropsch (FT) Fuel, JP-8+100, and Blends in a Three-Cup Combustor Sector

    Science.gov (United States)

    Thomas, Anna E.; Shouse, Dale T.; Neuroth, Craig; Lynch, Amy; Frayne, Charles W.; Stutrud, Jeffrey S.; Corporan, Edwin; Hankins, Terry; Saxena, Nikita T.; Hendricks, Robert C.

    2012-01-01

    In order to realize alternative fueling for military and commercial use, the industry has set forth guidelines that must be met by each fuel. These aviation fueling requirements are outlined in MIL-DTL-83133F(2008) or ASTM D 7566-Annex standards and are classified as drop-in fuel replacements. This paper provides combustor performance data for synthetic-paraffinic-kerosene- (SPK-) type (Fisher-Tropsch (FT)) fuel and blends with JP-8+100, relative to JP-8+100 as baseline fueling. Data were taken at various nominal inlet conditions: 75 psia (0.52 MPa) at 500 aF (533 K), 125 psia (0.86 MPa) at 625 aF (603 K), 175 psia (1.21 MPa) at 725 aF (658 K), and 225 psia (1.55 MPa) at 790 aF (694 K). Combustor performance analysis assessments were made for the change in flame temperatures, combustor efficiency, wall temperatures, and exhaust plane temperatures at 3%, 4%, and 5% combustor pressure drop (% P) for fuel:air ratios (F/A) ranging from 0.010 to 0.025. Significant general trends show lower liner temperatures and higher flame and combustor outlet temperatures with increases in FT fueling relative to JP-8+100 fueling. The latter affects both turbine efficiency and blade/vane life. In general, 100% SPK-FT fuel and blends with JP-8+100 produce less particulates and less smoke and have lower thermal impact on combustor hardware.

  20. H2O removal from diesel and JP8 fuels: A comparison study between synthetic and natural dehydration agents

    Directory of Open Access Journals (Sweden)

    E. P. Favvas

    2014-08-01

    Full Text Available The comparison between Thermal Polyaspartate Anion, TPA, and natural resin in their effect on the improvement of the physicochemical properties of both conventional diesel and JP8 fuels is the main scope of this work. Specifically, both studied materials were used dehydration agents in order to increase the physicochemical properties of both treated fuels. The higher amount of the removed water was obtained when used the natural resin as adsorbent material. In this case the water concentration decreased into diesel up to 68.66 % and more than 30 % in the case of jet fuel (JP8. This water removal improves the studied physicochemical properties of both studied fuels, diesel and JP8, for example up to 633 J/g (using natural resin as dehydration agent (removable additive and 1040 J/g (using TPA as dehydration agent for the heat of combustion. Overall, the proposed method can be used in a simple fuel cleaning process using a metal mesh vessel of synthetic TPA polymer or natural resin. The higher water/humidity removal amount in conjunction with the very low price of the natural resin makes this material more promising for the up scaling of the proposed technique in the near future.

  1. Role of Volatility in the Development of JP-8 Surrogates for Diesel Engine Application

    Science.gov (United States)

    2014-01-01

    rail solenoid injector with a single-hole nozzle is mounted at an angle about 28º from the vertical axis, delivering the fuel into the center of the...the combustion chamber along the axial direction. The first thermocouple measures the charge temperature close by the injector nozzle , and the second...Development of JP-8 Surrogates for Diesel Engine Application Author, co-author (Do NOT enter this information. It will be pulled from participant

  2. Quantitative discrimination of Aggregatibacter actinomycetemcomitans highly leukotoxic JP2 clone from non-JP2 clones in diagnosis of aggressive periodontitis

    Directory of Open Access Journals (Sweden)

    Yoshida Akihiro

    2012-10-01

    Full Text Available Abstract Background Aggregatibacter actinomycetemcomitans is the etiological agent of periodontitis, and there is a strong association between clone JP2 and aggressive periodontitis in adolescents of African descent. The JP2 clone has an approximately 530-bp deletion (∆530 in the promoter region of the lkt/ltx gene, which encodes leukotoxin, and this clone has high leukotoxic activity. Therefore, this clone is very important in aggressive periodontitis. To diagnose this disease, culture methods and conventional PCR techniques are used. However, quantitative detection based on qPCR for the JP2 clone has not been developed due to genetic difficulties. In this study, we developed a qPCR-based quantification method specific to the JP2 clone. Methods Based on our analysis of the DNA sequence of the lkt/ltx gene and its flanking region, we designed a reverse primer specific for the ∆530 deletion border sequence and developed a JP2-specific PCR-based quantification method using this primer. We also analyzed the DNA sequence of the ∆530 locus and found it to be highly conserved (97–100% among 17 non-JP2 strains. Using the ∆530 locus, we designed a qPCR primer–probe set specific to non-JP2 clones. Next, we determined the numbers of JP2 and non-JP2 clone cells in the periodontal pockets of patients with aggressive periodontitis. Results The JP2-specific primers specifically amplified the genomic DNA of the A. actinomycetemcomitans JP2 clone and did not react with other bacterial DNA, whereas the non-JP2 specific primers reacted only with A. actinomycetemcomitans non-JP2 clones. Samples from the 88 periodontal sites in the 11 patients with aggressive periodontitis were analyzed. The bacterial cell numbers in 88 periodontal sites ranged from 0 to 4.8 × 108 (mean 1.28 × 107 for JP2 clones and from 0 to 1.6 × 106 for non-JP2 clones (mean 1.84 × 105. There were significant differences in the JP2 cell number between a clinical attachment level

  3. Investigation of the mixture flow rates of oil-water two-phase flow using the turbine flow meter

    International Nuclear Information System (INIS)

    Li Donghui; Feng Feifei; Wu Yingxiang; Xu Jingyu

    2009-01-01

    In this work, the mixture flow rate of oil-water flows was studied using the turbine flow-meter. The research emphasis focuses on the effect of oil viscosity and input fluids flow rates on the precision of the meter. Experiments were conducted to measure the in-situ mixture flow rate in a horizontal pipe with 0.05m diameter using seven different viscosities of white oil and tap water as liquid phases. Results showed that both oil viscosity and input oil fraction exert a remarkable effect on measured results, especially when the viscosity of oil phase remained in the area of high value. In addition, for metering mixture flow rate using turbine flow-meter, the results are not sensitive to two-phase flow pattern according to the experimental data.

  4. Two-channel neutron boron meter

    International Nuclear Information System (INIS)

    Chen Yongqing; Yin Guowei; Chai Songshan; Deng Zhaoping; Zhou Bin

    1993-09-01

    The two-channel neutron boron meter is a continuous on-line measuring device to measure boron concentration of primary cooling liquid of reactors. The neutron-leakage-compensation method is taken in the measuring mechanism. In the primary measuring configuration, the mini-boron-water annulus and two-channel and central calibration loop are adopted. The calibration ring and constant-temperature of boron-water can be remotely controlled by secondary instruments. With the microcomputer data processing system the boron concentration is automatically measured and calibrated in on-line mode. The meter has many advantages such as high accuracy, fast response, multi-applications, high reliability and convenience

  5. Combustion phenomenon, performance and emissions of a diesel engine with aviation turbine JP-8 fuel and rapeseed biodiesel blends

    International Nuclear Information System (INIS)

    Labeckas, Gvidonas; Slavinskas, Stasys

    2015-01-01

    Highlights: • The 5 vol% RME added to JP-8 fuel improved lubricity 1.7 times according corrected wear scar diameter, μm. • The reverse trends revealed in the autoignition delay when operating with identical fuel blends J10 and B10. • The brake thermal efficiency increased by 1.0–3.6% when running on bio-fuels J5–J30 at speed of 2200 rpm. • The NO_x emissions increased by 5.2% when operating on bio-jet fuel J30 at full load and speed of 2200 rpm. • CO, HC emissions and smoke decreased with biofuel J20 and higher blends at both speeds of 1400 and 2200 rpm. - Abstract: The article presents the test results of an engine operating with diesel fuel (B5), turbine type JP-8 fuel and its 5 vol%, 10 vol%, 20 vol%, and 30 vol% blends with rapeseed oil methyl ester (RME). Additional fuel blend B10 was prepared by pouring 10 vol% of RME to diesel fuel to extend interpretation of the test results. The purpose of this study was to examine the effects of using jet-biodiesel fuel blends J5, J10, J20, J30, and B10 on the start of injection, ignition delay, combustion history, heat release, engine performance, and exhaust emissions. The engine performance parameters were examined at light 15% (1400 rpm) and 10% (2200 rpm), medium 50%, and high 100% loads and the two speeds: 1400 rpm at which maximum torque occurs and a rated speed of 2200 rpm. The autoignition delay and maximum heat release rate decreased, maximum cylinder pressure, and pressure gradients increased, whereas brake specific fuel consumption changed little and brake thermal efficiency was 1.0–3.6% higher when running with fuel blends J5 to J30 at rated speed compared with the data measured with neat jet fuel. The NO_x emissions increased slightly, but the CO, THC emissions, and smoke opacity boosted up significantly when using jet fuel blend J10 with a smooth reduction of unburned hydrocarbons for jet-biodiesel fuel blends with higher CN ratings. Operation at a full (100%) load with fuel blend J10

  6. 8 Meter Advanced Technology Large-Aperture Space Telescope (ATLAST-8m)

    Science.gov (United States)

    Stahl, H. Philip

    2010-01-01

    ATLAST-8m (Advanced Technology Large Aperture Space Telescope) is a proposed 8-meter monolithic UV/optical/NIR space observatory (wavelength range 110 to 2500 nm) to be placed in orbit at Sun-Earth L2 by NASA's planned Ares V heavy lift vehicle. Given its very high angular resolution (15 mas @ 500 nm), sensitivity and performance stability, ATLAST-8m is capable of achieving breakthroughs in a broad range of astrophysics including: Is there life elsewhere in the Galaxy? An 8-meter UVOIR observatory has the performance required to detect habitability (H2O, atmospheric column density) and biosignatures (O2, O3, CH4) in terrestrial exoplanet atmospheres, to reveal the underlying physics that drives star formation, and to trace the complex interactions between dark matter, galaxies, and intergalactic medium. The ATLAST Astrophysics Strategic Mission Concept Study developed a detailed point design for an 8-m monolithic observatory including optical design; structural design/analysis including primary mirror support structure, sun shade and secondary mirror support structure; thermal analysis; spacecraft including structure, propulsion, GN&C, avionics, power systems and reaction wheels; mass and power budgets; and system cost. The results of which were submitted by invitation to NRC's 2010 Astronomy & Astrophysics Decadal Survey.

  7. Turbojet Performance and Operation at High Altitudes with Hydrogen and Jp-4 Fuels

    Science.gov (United States)

    Fleming, W A; Kaufman, H R; Harp, J L , Jr; Chelko, L J

    1956-01-01

    Two current turbojet engines were operated with gaseous-hydrogen and JP-4 fuels at very high altitudes and a simulated Mach number of 0.8. With gaseous hydrogen as the fuel stable operation was obtained at altitudes up to the facility limit of about 90,000 feet and the specific fuel consumption was only 40 percent of that with JP-4 fuel. With JP-4 as the fuel combustion was unstable at altitudes above 60,000 to 65,000 feet and blowout limits were reached at 75,000 to 80,000 feet. Over-all performance, component efficiencies, and operating range were reduced considerable at very high altitudes with both fuels.

  8. Thermal emissivity analysis of a GEMINI 8-meter telescopes design

    Science.gov (United States)

    St. Clair Dinger, Ann

    1993-01-01

    The GEMINI 8-meter Telescopes Project is designing twin 8-meter telescopes to be located in Hawaii and Chile. The GEMINI telescopes will have interchangeable secondary mirrors for use in the visible and IR. The APART/PADE program is being used to evaluate the effective IR emissivity of the IR configuration plus enclosure as a function of mirror contamination at three IR wavelengths. The goal is to design a telescope whose effective IR emissivity is no more than 2 percent when the mirrors are clean.

  9. Design for an 8 Meter Monolithic UV/OIR Space Telescope

    Science.gov (United States)

    Stahl, H. Philip; Postman, Marc; Hornsby, Linda; Hopkins, Randall; Mosier, Gary E.; Pasquale, Bert A.; Arnold, William R.

    2009-01-01

    ATLAST-8 is an 8-meter monolithic UV/optical/NIR space observatory to be placed in orbit at Sun-Earth L2 by NASA's planned Ares V cargo launch vehicle. The ATLAST-8 will yield fundamental astronomical breakthroughs. The mission concept utilizes two enabling technologies: planned Ares-V launch vehicle (scheduled for 2019) and autonomous rendezvous and docking (AR&D). The unprecedented Ares-V payload and mass capacity enables the use of a massive, monolithic, thin-meniscus primary mirror - similar to a VLT or Subaru. Furthermore, it enables simple robust design rules to mitigate cost, schedule and performance risk. AR&D enables on-orbit servicing, extending mission life and enhancing science return.

  10. Stability of the JP2 clone of Aggregatibacter actinomycetemcomitans.

    Science.gov (United States)

    Haubek, D; Ennibi, O-K; Vaeth, M; Poulsen, S; Poulsen, K

    2009-09-01

    The JP2 clone of Aggregatibacter actinomycetemcomitans is strongly associated with aggressive periodontitis. To obtain information about colonization dynamics of the JP2 clone, we used PCR to examine its presence in 365 Moroccan juveniles from whom periodontal plaque samples were collected at baseline and after one and two years. Periodontal attachment loss was measured at baseline and at the two-year follow-up. At baseline, 43 (12%) carriers of the JP2 clone were found. Nearly half (44 %) of these were persistently colonized with the clone. The relative risk for the development of aggressive periodontitis, adjusted for the concomitant presence of other genotypes of A. actinomycetemcomitans, was highest for individuals continuously infected by the JP2 clone (RR = 13.9; 95% CI, 9.0 to 21.4), indicating a relationship between infectious dose and disease, which further substantiates the evidence for the JP2 clone as a causal factor in aggressive periodontitis.

  11. Design, integration and demonstration of a 50 W JP8/kerosene fueled portable SOFC power generator

    Science.gov (United States)

    Cheekatamarla, Praveen K.; Finnerty, Caine M.; Robinson, Charles R.; Andrews, Stanley M.; Brodie, Jonathan A.; Lu, Y.; DeWald, Paul G.

    A man-portable solid oxide fuel cell (SOFC) system integrated with desulfurized JP8 partial oxidation (POX) reformer was demonstrated to supply a continuous power output of 50 W. This paper discusses some of the design paths chosen and challenges faced during the thermal integration of the stack and reformer in aiding the system startup and shutdown along with balance of plant and power management solutions. The package design, system capabilities, and test results of the prototype unit are presented.

  12. MICRONUCLEUS STUDIES IN THE PERIPHERAL BLOOD AND BONE MARROW OF MICE TREATED WITH JET FUELS, JP-8 AND JET-A

    Science.gov (United States)

    The potential adverse effects of dermal and inhalation exposure of jet fuels are important for health hazard evaluation in humans. In an animal model, the genotoxic potential of jet fuels, JP-8 and Jet-A, was investigated. Mice were treated dermally with either a single or multip...

  13. PELATIHAN RENANG GAYA DADA 8 KALI 25 METER 4 SET LEBIH MENINGKATKAN KECEPATAN RENANG 100 METER GAYA DADA DARIPADA 4 KALI 50 METER 4 SET PADA RENANG PEMULA PUTRA

    Directory of Open Access Journals (Sweden)

    I Wayan Suarta

    2013-07-01

    Full Text Available Sports pool in Indonesia are well known to the public, which is reduced when driving (after the end of the recovery to begin hand pull another hand, the breaststroke is the style of the most interesting because it does not quickly tiring when compared with other styles, because the process of respiration take place with ease, making them easier use in long-distance swim, at the start to affect the pace to continue this next movement needs to get training and a variety of training models, especially at students aged 10-12 years. Training pool 8 times 25 times 50 meters and 4 meters is one of the training methods that can speed up travel time. The best training model has not been encountered in the data. So do the research to find a model training 25 meter pool 8 times and 4 times 4 sets of 50 meters. The study was conducted with pretest-postes group design. Samples taken from the novice swimmer Toya Ening on Dalung Badung, as many as 26 people were randomly selected simple. Samples were divided into 2 groups each group totaled 13 people. Both groups were equally give training in the first group to pool 8 by 25 feet 4 sets, and 4 times the second group of 4 sets of 50 meters. 0.05 ab. Differences in results were analyzed statistically with  The data analyzed were age, height, weight, leg length and physical fitness.  13.49 seconds.± 107.69, and 126.38 ±The mean test results of the final 100 meter breaststroke swimming in a row 12.14 seconds  F count the results obtained respectively by 0.95 seconds with p = 0.59 and 0.93 seconds with a value of p = 0.34. Data showed significant differences significant (p> 0.05. These results indicate that the training of swimming the breaststroke 8 by 25 feet 4 sets is better than 4 times in 4 sets of 50 meter speed up travel time 100-meter breaststroke swimming novice men (p <0.05. Suggested the use of breaststroke swimming training method 8 by 25 feet 4 sets to be intensified to provide training pool at 100

  14. Incorporating detrital conditioning in outdoor microcosms dosed with JP-8 jet fuel

    International Nuclear Information System (INIS)

    Matthews, R.A.; Markiewicz, A.; Harter, V.; Landis, W.G.

    1995-01-01

    The authors have developed an outdoor microcosm system that incorporates detrital conditioning to test the hypothesis that microbiota play a critical role in altering the community response to hydrocarbon toxicants. The microcosms were constructed using 568 L tanks, arranged in 6 units of 4 tanks, with each unit equidistant from a central conditions tank (CT). During pre-treatment, the microcosms and CT were filled with nutrient-amended well water, artificial sediment, leaf packs containing dried maple leaves, elodea fragment, and unglazed tiles for periphyton growth. Water circulation was maintained at the rate of 24 exchanges per day. After four weeks, invertebrates from local ponds were added to the CT. Leafpacks were added to the CT and microcosms every two weeks; eight week old packs were discarded after returning invertebrates to the CT. On a weekly basis, 25% of the sediments, leaf packs, tiles, and elodea from each microcosms were transferred to another microcosm; the CT walls and tiles were scraped; an the water quality was monitored. Circulation was discontinued one week prior to dosing. On 4/12/96, the microcosms were dosed to contain 0--0.25 microg/L of JP-8 jet fuel. Within two weeks the GC/MS hydrocarbon concentrations were very low in the water column of the highest treatment group. There has been little acute toxicity, despite selecting doses that caused severe, acute toxicity in laboratory microcosm studies. The presence of a complex, detritus-based microbial community appears to mitigate the influences of the toxicant on the microcosms

  15. 76 FR 41829 - J.P. Morgan Securities LLC, et al.; Notice of Application and Temporary Order

    Science.gov (United States)

    2011-07-15

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. IC-29719; 812-13919] J.P. Morgan Securities LLC... entered against J.P. Morgan Securities LLC (``JPMS'') on July 8, 2011 by the United States District Court... Distribution Services, Inc. (``JPMDS''), J.P. Morgan Institutional Investments, Inc. (``JPMII''), J.P. Morgan...

  16. Design and development of a diesel and JP-8 logistic fuel processor

    Science.gov (United States)

    Roychoudhury, Subir; Lyubovsky, Maxim; Walsh, D.; Chu, Deryn; Kallio, Erik

    The paper describes the design and performance of a breadboard prototype for a 5 kW fuel-processor for powering a solid oxide fuel cell (SOFC) stack. The system was based on a small, modular catalytic Microlith auto-thermal (ATR) reactor with the versatility of operating on diesel, Jet-A or JP-8 fuels. The reforming reactor utilized Microlith substrates and catalyst technology (patented and trademarked). These reactors have demonstrated the capability of efficiently reforming liquid and gaseous hydrocarbon fuels at exceptionally high power densities. The performance characteristics of the auto-thermal reactor (ATR) have been presented along with durability data. The fuel processor integrates fuel preparation, steam generation, sulfur removal, pumps, blowers and controls. The system design was developed via ASPEN ® Engineering Suite process simulation software and was analyzed with reference to system balance requirements. Since the fuel processor has not been integrated with a fuel cell, aspects of thermal integration with the stack have not been specifically addressed.

  17. Evaluation of Fatty Acid Methyl Ester (FAME) Contamination on the Thermal Stability Characteristics of Military Jet Fuels (JP-8 And JP-5)

    Science.gov (United States)

    2013-12-01

    of increased contamination levels of FAME in Jet A, FAME material will likely be transported in the same conveyance as JP-5 – bringing with it the...is a blend of four common biodiesel (FAME) fuels from different feedstocks. All FAME contaminated fuels were prepared with this FAME material at a

  18. Thermodynamic, Transport and Chemical Properties of Reference JP-8

    Science.gov (United States)

    2006-06-01

    external diameter, 0.18 cm internal diameter) that are sealed on one end with a stainless steel plug welded by a clean tungsten-inert-gas ( TIG ) 15...tubing with an internal diameter of 0.02 cm, also TIG welded to the cell. Each cell and valve is capable of withstanding a pressure in excess of 105... process . Each cell is connected to a high-pressure high-temperature valve at the other end with a short length of 0.16 cm diameter 316 stainless steel

  19. Two laboratory methods for the calibration of GPS speed meters

    International Nuclear Information System (INIS)

    Bai, Yin; Sun, Qiao; Du, Lei; Yu, Mei; Bai, Jie

    2015-01-01

    The set-ups of two calibration systems are presented to investigate calibration methods of GPS speed meters. The GPS speed meter calibrated is a special type of high accuracy speed meter for vehicles which uses Doppler demodulation of GPS signals to calculate the measured speed of a moving target. Three experiments are performed: including simulated calibration, field-test signal replay calibration, and in-field test comparison with an optical speed meter. The experiments are conducted at specific speeds in the range of 40–180 km h −1 with the same GPS speed meter as the device under calibration. The evaluation of measurement results validates both methods for calibrating GPS speed meters. The relative deviations between the measurement results of the GPS-based high accuracy speed meter and those of the optical speed meter are analyzed, and the equivalent uncertainty of the comparison is evaluated. The comparison results justify the utilization of GPS speed meters as reference equipment if no fewer than seven satellites are available. This study contributes to the widespread use of GPS-based high accuracy speed meters as legal reference equipment in traffic speed metrology. (paper)

  20. A comparison of optimum JP and LH2 turbofan engines designed for two subsonic transport missions

    Science.gov (United States)

    Civinskas, K. C.

    1974-01-01

    The use of liquid hydrogen fuel instead of JP fuel for two subsonic commercial transports was examined. The following determinations which are important to meeting noise reduction requirements were calculated: (1) take off gross weight, (2) energy consumption, and (3) direct operating costs. The optimum engine cycles were found to be the same for both fuels.

  1. Formation and surface strengthening of nano-meter embedded phases during high energy Ti implanted and annealed steel

    International Nuclear Information System (INIS)

    Zhang Tonghe; Wu Yuguang; Cui Ping; Wang Ping

    1999-12-01

    Observation of transmission electron microscope indicated that the phase of FeTi 2 with 3.5-20 nm in diameter is embedded in high energy Ti implanted layer. It's average diameter is 8 nm. The nano-meter phases were embedded among dislocations and grain boundary in Ti implanted steel at 400 degree C. The wear resistance has been improved. The embedded structure can be changed obviously after annealing. The structure has been changed slightly after annealing at annealing temperature raging from 350 to 500 degree C, however, the hardness and wear resistance of implanted layer increased greatly. The maximum of hardness is obtained when the sample was annealed at 500 degree C for 20 min. It can be seen that the strengthening of implanted layer has enhanced by annealing indeed. The grain boundary and dislocations have disappeared; the diameter of nano-meter phases increased from 10 nm to 15 nm after annealing at temperature of 750 degree C and 1000 degree respectively. The average densities of nano-meter phases are 8.8 x 10 10 /cm 2 and 6.5 x 10 10 /cm 2 respectively for both of annealing temperature. The hardness decreased obviously when the annealing temperature is greater than 750 degree C

  2. 75 FR 3251 - JP Morgan Chase and Company; JP Morgan Investment Banking, Global Corporate Financial Operations...

    Science.gov (United States)

    2010-01-20

    ... Company; JP Morgan Investment Banking, Global Corporate Financial Operations, New York, NY; Notice of... Company, JP Morgan Investment Banking, Global Corporate Financial Operations, New York, New York. The... support operations to/from a foreign country. The subject firm did not import services like or directly...

  3. Analysis list: Chd8 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Chd8 Blood,Embryo + mm9 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/target/Chd8.1.tsv http:...//dbarchive.biosciencedbc.jp/kyushu-u/mm9/target/Chd8.5.tsv http://dbarchive.biosciencedbc.jp/kyu...shu-u/mm9/target/Chd8.10.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/colo/Chd8.Blood.tsv,http://dbarc...hive.biosciencedbc.jp/kyushu-u/mm9/colo/Chd8.Embryo.tsv http://dbarchive.bioscien...cedbc.jp/kyushu-u/mm9/colo/Blood.gml,http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/colo/Embryo.gml ...

  4. Effect of Loop Diameter on the Steady State and Stability Behaviour of Single-Phase and Two-Phase Natural Circulation Loops

    Directory of Open Access Journals (Sweden)

    P. K. Vijayan

    2008-01-01

    Full Text Available In natural circulation loops, the driving force is usually low as it depends on the riser height which is generally of the order of a few meters. The heat transport capability of natural circulation loops (NCLs is directly proportional to the flow rate it can generate. With low driving force, the straightforward way to enhance the flow is to reduce the frictional losses. A simple way to do this is to increase the loop diameter which can be easily adopted in pressure tube designs such as the AHWR and the natural circulation boilers employed in fossil-fuelled power plants. Further, the loop diameter also plays an important role on the stability behavior. An extensive experimental and theoretical investigation of the effect of loop diameter on the steady state and stability behavior of single- and two-phase natural circulation loops have been carried out and the results of this study are presented in this paper.

  5. MEETING IN VANCOUVER, B.C.: MICRONUCLEUS STUDIES IN THE PERIPHERAL BLOOD AND BONE MARROW OF MICE TREATED WITH JET FUELS, JP-8 AND JET-A

    Science.gov (United States)

    The potential adverse effects of dermal and inhalation exposure of jet fuels are important for health hazard evaluation in humans. In an animal model, the genotoxic potential of jet fuels, JP-8 and Jet-A, was investigated. Mice were treated dermally with either a single or multip...

  6. Propulsion and Power Rapid Response Research and Development (R&D) Support. Task Order 0011: JP-8+100 Development History and Maintenance Benefits

    Science.gov (United States)

    2010-06-01

    Flow Bench Showing Spray Ring Mounted ................................. 100 92. Effect of Additive Dosage Rates on Fuel Thermal Stability Rating...components to include the engine oil and the electronic control components. During aircraft descent , the engine fuel flow is decreased but the aircraft...evaluation of these materials was accomplished at both normal and 4-times (4X) normal dosage rates for JP-8+100 during a 28-day thermal aging cycle at

  7. The JP2 genotype of Aggregatibacter actinomycetemcomitans and marginal periodontitis in the mixed dentition

    DEFF Research Database (Denmark)

    Jensen, Anne Birkeholm; Ennibi, Oum Keltoum; Ismaili, Zouheir

    2016-01-01

    AIM: To perform a cross-sectional study on the carrier frequency of JP2 and non-JP2 genotypes of A. actinomycetemcomitans in Moroccan schoolchildren and relate the presence of these genotypes to the periodontal status in the mixed dentition. MATERIAL AND METHODS: A plaque sample from 513 children...... the JP2 genotype and 186 (36.3%) were positive for non-JP2 genotypes, whereas A. actinomycetemcomitans could not be detected in the remaining 281 subjects. Among 75 subjects with mixed dentition and selected for clinical examination, clinical attachment loss (CAL) ≥3 mm at two or more periodontal sites...

  8. A 90-day continuous vapor inhalation toxicity study of JP-8 jet fuel followed by 20 or 21 months of recovery in Fischer 344 rats and C57BL/6 mice.

    Science.gov (United States)

    Mattie, D R; Alden, C L; Newell, T K; Gaworski, C L; Flemming, C D

    1991-01-01

    The kerosene-type jet fuel, JP-8, consists of a complex mixture of aliphatic and aromatic hydrocarbons. Because of the utility of JP-8, studies have been conducted to identify the potential long-term consequence of occupational inhalation exposure. Fischer 344 rats and C57BL/6 mice of both sexes were exposed to JP-8 vapors at 0, 500, and 1,000 mg/m3 on a continuous basis for 90 days, then followed by recovery until approximately 24 months of age. Occurrence of necrotizing dermatitis associated with fighting resulted in an increase in mortality in mice (male greater than female) during the 2 week to 9 month post-exposure recovery period. The male rat kidney developed a reversible ultrastructural increase in size and propensity for crystalloid changes of phagolysosomal proteinic reabsorption droplets in the proximal convoluted tubular epithelium. A specific triad of persisting light microscopic renal lesions occurred but functional change was limited to a decrease in urine concentration compared to controls that persisted throughout the recovery period. The response is comparable to the chronic effect of lifetime exposure of the male rat to unleaded gasoline, d-limonene, and p-dichlorobenzene, except for the absence of tubular tumorigenesis. The active toxicologic response presumably must occur over a greater proportion of the male rat's life span for the tumor component of this male rat hydrocarbon nephropathy syndrome. The predictiveness for humans must be questioned, since the pathologic response to JP-8 involved only one tissue in one sex of one species, and since the male rat response appears to be linked to an inherent renal protein peculiarity.

  9. Conversion of Small Algal Oil Sample to JP-8

    Science.gov (United States)

    2012-01-01

    cracking of Algal Oil to SPK Hydroprocessing Lab Plant uop Nitrogen Hydrogen Product ., __ Small Scale Lab Hydprocessing plant - Down flow trickle ... bed configuration - Capable of retaining 25 cc of catalyst bed Meter UOP ·CONFIDENTIAL File Number The catalytic deoxygenation stage of the...content which combined with the samples acidity, is a challenge to reactor metallurgy. None the less, an attempt was made to convert this sample to

  10. Modified distribution parameter for churn-turbulent flows in large diameter channels

    Energy Technology Data Exchange (ETDEWEB)

    Schlegel, J.P., E-mail: jschlege@purdue.edu; Macke, C.J.; Hibiki, T.; Ishii, M.

    2013-10-15

    Highlights: • Void fraction data collected in pipe sizes up to 0.304 m using impedance void meters. • Flow conditions extend to transition between churn-turbulent and annular flow. • Flow regime identification results agree with previous studies. • A new model for the distribution parameter in churn-turbulent flow is proposed. -- Abstract: Two phase flows in large diameter channels are important in a wide range of industrial applications, but especially in analysis of nuclear reactor safety for the prediction of BWR behavior and safety analysis in PWRs. To remedy an inability of current drift-flux models to accurately predict the void fraction in churn-turbulent flows in large diameter pipes, extensive experiments have been performed in pipes with diameters of 0.152 m, 0.203 m and 0.304 m to collect area-averaged void fraction data using electrical impedance void meters. The standard deviation and skewness of the impedance meter signal have been used to characterize the flow regime and confirm previous flow regime transition results. By treating churn-turbulent flow as a transition between cap-bubbly dispersed flow and annular separated flow and using a linear ramp, the distribution parameter has been modified for churn-turbulent flow. The modified distribution parameter has been evaluated through comparison of the void fraction predicted by the drift-flux model and the measured void fraction.

  11. Modified distribution parameter for churn-turbulent flows in large diameter channels

    International Nuclear Information System (INIS)

    Schlegel, J.P.; Macke, C.J.; Hibiki, T.; Ishii, M.

    2013-01-01

    Highlights: • Void fraction data collected in pipe sizes up to 0.304 m using impedance void meters. • Flow conditions extend to transition between churn-turbulent and annular flow. • Flow regime identification results agree with previous studies. • A new model for the distribution parameter in churn-turbulent flow is proposed. -- Abstract: Two phase flows in large diameter channels are important in a wide range of industrial applications, but especially in analysis of nuclear reactor safety for the prediction of BWR behavior and safety analysis in PWRs. To remedy an inability of current drift-flux models to accurately predict the void fraction in churn-turbulent flows in large diameter pipes, extensive experiments have been performed in pipes with diameters of 0.152 m, 0.203 m and 0.304 m to collect area-averaged void fraction data using electrical impedance void meters. The standard deviation and skewness of the impedance meter signal have been used to characterize the flow regime and confirm previous flow regime transition results. By treating churn-turbulent flow as a transition between cap-bubbly dispersed flow and annular separated flow and using a linear ramp, the distribution parameter has been modified for churn-turbulent flow. The modified distribution parameter has been evaluated through comparison of the void fraction predicted by the drift-flux model and the measured void fraction

  12. JP-8 Final Risk Assessment

    Science.gov (United States)

    2001-08-01

    History of diabetes 8. History of scoliosis 9. Major visual impairment 10. Clinical diagnosis of seizures 11. On medical profile 12. Pregnancy 13...genotype is over-represented in patients with certain types of cancer. It has also been reported that the GST MI-null genotype is more prevalent among...induced haemolytic anaemia with haemoglobinuria. Indian J.Pediatr. 40, 195-197, 1973. 8. Hauf L.M. The development of a method Suitable for the

  13. In situ bioremediation of JP-5 jet fuel

    International Nuclear Information System (INIS)

    Eisman, M.P.; Dorwin, E.; Barnes, D.; Nelson, B.

    1991-01-01

    Fuel leaks and spills of the jet fuel JP-5 at various Naval installations are required by law to be remediated. Use of microorganisms for fuel spill remediation is the focus of this paper, which examines biodegradation of JP-5 by means of CO 2 evolution in batch cultures. In particular, the aerobic biodegradation of fresh and weathered JP-5, along with a representative fuel mix of three pure compounds, is examined. Since microorganisms exist in aqueous environments, the solubility in water of fuels and fuel components is also examined. Other chemical properties of the complex mixture of hydrocarbons in JP-5 may affect bioavailability. This paper will also attempt to relate biodegradation to these properties, particularly water solubility and type of hydrocarbon

  14. Two-Dimensional Key Table-Based Group Key Distribution in Advanced Metering Infrastructure

    OpenAIRE

    Woong Go; Jin Kawk

    2014-01-01

    A smart grid provides two-way communication by using the information and communication technology. In order to establish two-way communication, the advanced metering infrastructure (AMI) is used in the smart grid as the core infrastructure. This infrastructure consists of smart meters, data collection units, maintenance data management systems, and so on. However, potential security problems of the AMI increase owing to the application of the public network. This is because the transmitted in...

  15. 1400 Liter 1.8K Test Facility

    International Nuclear Information System (INIS)

    Peterson, T.J.; Rabehl, R.J.; Sylvester, C.D.

    1997-08-01

    A double bath superfluid helium dewar has been constructed and operated at Fermilab's Magnet Test Facility. The 1.8 K portion of the dewar is sized to contain a superconducting magnet up to 0.5 meters in diameter and 4 meters long in a vertical orientation in 0.12 MPa pressurized superfluid. The dewar can also provide a subcooled Helium I environment for tests; the entire temperature range from 4.4 K to 1. 8 K at 0.12 MPa is available. This paper describes the system design, lambda plate, heat exchanger, and performance

  16. Calibration of PKA meters against ion chambers of two geometries

    International Nuclear Information System (INIS)

    Almeida Junior, Jose N.; Terini, Ricardo A.; Pereira, Marco A.G.; Herdade, Silvio B.

    2011-01-01

    Kerma-area product (KAP or PKA) is a quantity that is independent of the distance to the X-ray tube focal spot and that can be used in radiological exams to assess the effective dose in patients. Clinical KAP meters are generally fixed in tube output and they are usually calibrated on-site by measuring the air kerma with an ion chamber and by evaluating the irradiated area by means of a radiographic image. Recently, a device was marketed (PDC, Patient Dose Calibrator, Radcal Co.), which was designed for calibrating clinical KAP meters with traceability to a standard laboratory. This paper presents a metrological evaluation of two methods that can be used in standard laboratories for the calibration of this device, namely, against a reference 30 cc ionization chamber or a reference parallel plates monitor chamber. Lower energy dependence was also obtained when the PDC calibration was made with the monitor chamber. Results are also shown of applying the PDC in hospital environment to the cross calibration of a clinical KAP meter from a radiology equipment. Results confirm lower energy dependence of the PDC relatively to the tested clinical meter. (author)

  17. An experimental study on two-phase pressure drop in small diameter horizontal, downward inclined and vertical tubes

    Directory of Open Access Journals (Sweden)

    Autee Arun

    2015-01-01

    Full Text Available An experimental study of two-phase pressure drop in small diameter tubes orientated horizontally, vertically and at two other downward inclinations of θ= 300 and θ = 600 is described in this paper. Acrylic transparent tubes of internal diameters 4.0, 6.0, and 8.0 mm with lengths of 400 mm were used as the test section. Air-water mixture was used as the working fluid. Two-phase pressure drop was measured and compared with the existing correlations. These correlations are commonly used for calculation of pressure drop in macro and mini-microchannels. It is observed that the existing correlations are inadequate in predicting the two-phase pressure drop in small diameter tubes. Based on the experimental data, a new correlation has been proposed for predicting the two-phase pressure drop. This correlation is developed by modification of Chisholm parameter C by incorporating different parameters. It was found that the proposed correlation predicted two-phase pressure drop at satisfactory level.

  18. Reservoir computer predictions for the Three Meter magnetic field time evolution

    Science.gov (United States)

    Perevalov, A.; Rojas, R.; Lathrop, D. P.; Shani, I.; Hunt, B. R.

    2017-12-01

    The source of the Earth's magnetic field is the turbulent flow of liquid metal in the outer core. Our experiment's goal is to create Earth-like dynamo, to explore the mechanisms and to understand the dynamics of the magnetic and velocity fields. Since it is a complicated system, predictions of the magnetic field is a challenging problem. We present results of mimicking the three Meter experiment by a reservoir computer deep learning algorithm. The experiment is a three-meter diameter outer sphere and a one-meter diameter inner sphere with the gap filled with liquid sodium. The spheres can rotate up to 4 and 14 Hz respectively, giving a Reynolds number near to 108. Two external electromagnets apply magnetic fields, while an array of 31 external and 2 internal Hall sensors measure the resulting induced fields. We use this magnetic probe data to train a reservoir computer to predict the 3M time evolution and mimic waves in the experiment. Surprisingly accurate predictions can be made for several magnetic dipole time scales. This shows that such a complicated MHD system's behavior can be predicted. We gratefully acknowledge support from NSF EAR-1417148.

  19. Two-phase flow structure in large diameter pipes

    International Nuclear Information System (INIS)

    Smith, T.R.; Schlegel, J.P.; Hibiki, T.; Ishii, M.

    2012-01-01

    Highlights: ► Local profiles of various quantities measured in large diameter pipe. ► Database for interfacial area in large pipes extended to churn-turbulent flow. ► Flow regime map confirms previous models for flow regime transitions. ► Data will be useful in developing interfacial area transport models for large pipes. - Abstract: Flow in large pipes is important in a wide variety of applications. In the nuclear industry in particular, understanding of flow in large diameter pipes is essential in predicting the behavior of reactor systems. This is especially true of natural circulation Boiling Water Reactor (BWR) designs, where a large-diameter chimney above the core provides the gravity head to drive circulation of the coolant through the reactor. The behavior of such reactors during transients and during normal operation will be predicted using advanced thermal–hydraulics analysis codes utilizing the two-fluid model. Essential to accurate two-fluid model calculations is reliable and accurate computation of the interfacial transfer terms. These interfacial transfer terms can be expressed as the product of one term describing the potential driving the transfer and a second term describing the available surface area for transfer, or interfacial area concentration. Currently, the interfacial area is predicted using flow regime dependent empirical correlations; however the interfacial area concentration is best computed through the use of the one-dimensional interfacial area transport equation (IATE). To facilitate the development of IATE source and sink term models in large-diameter pipes a fundamental understanding of the structure of the two-phase flow is essential. This understanding is improved through measurement of the local void fraction, interfacial area concentration and gas velocity profiles in pipes with diameters of 0.102 m and 0.152 m under a wide variety of flow conditions. Additionally, flow regime identification has been performed to

  20. Two-group interfacial area concentration correlations of two-phase flows in large diameter pipes

    International Nuclear Information System (INIS)

    Shen, Xiuzhong; Hibiki, Takashi

    2015-01-01

    The reliable empirical correlations and models are one of the important ways to predict the interfacial area concentration (IAC) in two-phase flows. However, up to now, no correlation or model is available for the prediction of the IAC in the two-phase flows in large diameter pipes. This study collected an IAC experimental database of two-phase flows taken under various flow conditions in large diameter pipes and presented a systematic way to predict the IAC for two-phase flows from bubbly, cap-bubbly to churn flow in large diameter pipes by categorizing bubbles into two groups (group-1: spherical and distorted bubble, group-2: cap bubble). Correlations were developed to predict the group-1 void fraction from the void fraction of all bubble. The IAC contribution from group-1 bubbles was modeled by using the dominant parameters of group-1 bubble void fraction and Reynolds number based on the parameter-dependent analysis of Hibiki and Ishii (2001, 2002) using one-dimensional bubble number density and interfacial area transport equations. A new drift velocity correlation for two-phase flow with large cap bubbles in large diameter pipes was derived in this study. By comparing the newly-derived drift velocity correlation with the existing drift velocity correlation of Kataoka and Ishii (1987) for large diameter pipes and using the characteristics of the representative bubbles among the group 2 bubbles, we developed the model of IAC and bubble size for group 2 cap bubbles. The developed models for estimating the IAC are compared with the entire collected database. A reasonable agreement was obtained with average relative errors of ±28.1%, ±54.4% and ±29.6% for group 1, group 2 and all bubbles respectively. (author)

  1. Two-Phase Quality/Flow Meter

    Science.gov (United States)

    Moerk, J. Steven (Inventor); Youngquist, Robert C. (Inventor); Werlink, Rudy J. (Inventor)

    1999-01-01

    A quality and/or flow meter employs a capacitance probe assembly for measuring the dielectric constant of flow stream, particularly a two-phase flow stream including liquid and gas components.ne dielectric constant of the flow stream varies depending upon the volume ratios of its liquid and gas components, and capacitance measurements can therefore be employed to calculate the quality of the flow, which is defined as the volume ratio of liquid in the flow to the total volume ratio of gas and liquid in the flow. By using two spaced capacitance sensors, and cross-correlating the time varying capacitance values of each, the velocity of the flow stream can also be determined. A microcontroller-based processing circuit is employed to measure the capacitance of the probe sensors.The circuit employs high speed timer and counter circuits to provide a high resolution measurement of the time interval required to charge each capacitor in the probe assembly. In this manner, a high resolution, noise resistant, digital representation of each of capacitance value is obtained without the need for a high resolution A/D converter, or a high frequency oscillator circuit. One embodiment of the probe assembly employs a capacitor with two ground plates which provide symmetry to insure that accurate measurements are made thereby.

  2. Propulsion and Power Rapid Response Research and Development (R&D) Support. Delivery Order 0011: Advanced Propulsion Fuels R&D, Subtask: Evaluation of 50/50 Hydroprocessed Renewable Jet Fuel and JP8 in the Ford 6.7L High-Pressure Common Rail Design Engine

    Science.gov (United States)

    2012-12-01

    47 42. AF7938 50/50 JP-8/HRJ, Rear Pump Body Camshaft Bushing ........................................... 48 iii Approved for public...release; distribution unlimited. LIST OF FIGURES (Cont’d) Figure Page 43. AF7938 50/50 JP-8/HRJ, Front Pump Body Camshaft Bushing ...atmosphere. A butterfly valve was used to regulate engine exhaust backpressure to the Ford recommended 11psi specification. • Emissions were

  3. Interference studies with two hospital-grade and two home-grade glucose meters.

    Science.gov (United States)

    Lyon, Martha E; Baskin, Leland B; Braakman, Sandy; Presti, Steven; Dubois, Jeffrey; Shirey, Terry

    2009-10-01

    Interference studies of four glucose meters (Nova Biomedical [Waltham, MA] StatStrip [hospital grade], Roche Diagnostics [Indianapolis, IN] Accu-Chek Aviva [home grade], Abbott Diabetes Care [Alameda, CA] Precision FreeStyle Freedom [home grade], and LifeScan [Milpitas, CA] SureStep Flexx [hospital grade]) were evaluated and compared to the clinical laboratory plasma hexokinase reference method (Roche Hitachi 912 chemistry analyzer). These meters were chosen to reflect the continuum of care from hospital to home grade meters commonly seen in North America. Within-run precision was determined using a freshly prepared whole blood sample spiked with concentrated glucose to give three glucose concentrations. Day-to-day precision was evaluated using aqueous control materials supplied by each vendor. Common interferences, including hematocrit, maltose, and ascorbate, were tested alone and in combination with one another on each of the four glucose testing devices at three blood glucose concentrations. Within-run precision for all glucose meters was glucose meters. Ascorbate caused differences (percentage change from a sample without added interfering substances) of >5% with pyrroloquinolinequinone (PQQ)-glucose dehydrogenase-based technologies (Aviva and Freestyle) and the glucose oxidase-based Flexx meter. Maltose strongly affected the PQQ-glucose dehydrogenase-based meter systems. When combinations of interferences (ascorbate, maltose, and hematocrit mixtures) were tested, the extent of the interference was up to 193% (Aviva), 179% (FreeStyle), 25.1% (Flexx), and 5.9% (StatStrip). The interference was most pronounced at low glucose (3.9-4.4 mmol/L). All evaluated glucose meter systems demonstrated varying degrees of interference by hematocrit, ascorbate, and maltose mixtures. PQQ-glucose dehydrogenase-based technologies showed greater susceptibility than glucose oxidase-based systems. However, the modified glucose oxidase-based amperometric method (Nova StatStrip) was

  4. Smart meters. Smart metering. A solution module for a future-oriented energy system; Intelligente Zaehler. Smart Metering. Ein Loesungsbaustein fuer ein zukunftsfaehiges Energiesystem

    Energy Technology Data Exchange (ETDEWEB)

    Grimm, Nadia; Seidl, Hans [comps.

    2011-12-15

    The German Energy Agency GmbH (Berlin, Federal Republic of Germany) reports on smart metering as a solution module for a future-oriented energy system by means of the following contributions: (1) Key role for smart meters; (2) What is smart metering? (3) Implementation of smart metering in Europe; (4) The market development to date in Germany; (5) Practical experiences with smart metering in Germany; (6) Frequently asked questions; (7) Smart metering in intelligent networks; (8) Legal framework conditions; (9) Data security and data protection in the utilisation of smart meters; (10) Ongoing information; (11) Efficient energy systems.

  5. Characteristics of two-phase flows in large diameter channels

    Energy Technology Data Exchange (ETDEWEB)

    Schlegel, J.P., E-mail: schlegelj@mst.edu [Department of Mining and Nuclear Engineering, Missouri University of Science and Technology, 301 W 14th St., Rolla, MO 65401 (United States); Hibiki, T.; Ishii, M. [School of Nuclear Engineering, Purdue University, 400 Central Dr., West Lafayette, IN 47907 (United States)

    2016-12-15

    Two-phase flows in large diameter channels have a great deal of importance in a wide variety of industrial applications. Nuclear systems, petroleum refineries, and chemical processes make extensive use of larger systems. Flows in such channels have very different properties from flows in smaller channels which are typically used in experimental research. In this paper, the various differences between flows in large and small channels are highlighted using the results of previous experimental and analytical research. This review is followed by a review of recent experiments in and model development for flows in large diameter channels performed by the authors. The topics of these research efforts range from void fraction and interfacial area concentration measurement to flow regime identification and modeling, drift-flux modeling for high void fraction conditions, and evaluation of interfacial area transport models for large diameter channels.

  6. 1000 meters water depth rigid TLP riser; Riser rigido de plataforma de pernas atirantadas para lamina d'agua de 1000 metros

    Energy Technology Data Exchange (ETDEWEB)

    Braga, Mauro Jacinto Pastor

    1990-07-01

    A procedure to estimate the fatigue life of a TLP riser in 1000 meters water depth based on a hydro-elastic analysis of an integrated riser-TLP model in the time domain is presented . The computational architecture is shown that makes it feasible to process and store the great amount of data involved. The procedure is applied to a 1000 meters water depth TLP with a set of 40 risers 8 inches in diameter equipped with a floatation layer. (author)

  7. 300 GHz Imaging System with 8 Meter Stand-off Distance and One-Dimensional Synthetic Image Reconstruction for Remote Detection of Material Defects

    DEFF Research Database (Denmark)

    Keil, Andreas; Peuser, Jörn; Loeffler, Torsten

    2011-01-01

    An active stand-off imaging system operating at 230–320 GHz is presented. Imaging is achieved by combining a line array consisting of 8 sources and 16 detectors with a scanning cylindrical mirror system. The stand-off distance is 8 meters and the effective aperture of the system is 0.5 meters by ...

  8. Two survey meters for measuring low γ-ray dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1979-01-01

    Two low-level survey meters have been developed which have numerical displays. The first is of the light-emitting diode (LED) type. The second is a liquid crystal display (LCD). The design of both instruments is described and results of measurements of performance are presented. They measure γ dose rates from background up to 2 mrad/h (20 μGy/h) for γ-rays in the energy range 0.05-1.25 MeV. They can be used at temperatures between -20 deg C and +50 deg C. Statistical accuracy and battery life both depend upon a number of factors and this dependence is shown. A later section describes the intended application of the survey meters. An appendix describes the circuit adjustments which are necessary and when they must be made. (author)

  9. Instrument evaluation no. 5. Wallac OY universal radiation survey meter type RD-8

    International Nuclear Information System (INIS)

    White, D.F.; Blundell, D.R.; Callowhill, K.; Iles, W.J.

    1976-05-01

    The Wallace RD-8 is a portable, battery-operated survey meter covering an exposure rate range from 0.01 mR/h to 300 R/h. The instrument was designed specifically for military and civil defence applications and is accordingly of particularly rugged construction and claimed to be both waterproof and shockproof. This instrument is unusual in that it has two internally mounted radiation detectors. An end-window GM tube is used to cover the range from 0.01 to 300 mR/h, and a GM tube covers the range from 0.01 to 300 R/h. Both tubes have energy compensation sheaths for the measurement of photon radiation in the forward direction. Only the first tube permits the measurement of β-radiation. The information is given under the following headings; Facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; summary of performance; calibration procedure; conclusions. (U.K.)

  10. Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

    Science.gov (United States)

    Huz, Kateryna

    2014-01-01

    RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better

  11. Investigation of Aerogel/Xerogel Catalysts for Autothermal Reforming of JP-8

    Science.gov (United States)

    2013-12-19

    The C 1s line at 284.6 eV was used as an internal standard for the correction of binding energies. SEM-EDAX analysis was carried out at FEI Helios 600...carrier gas) and argon ( internal standard) were metered into the system by AALBORG AFC 3600 mass flow controllers. Flows of fuel and water were both...framework with a minor microporous range. With the incorporation of Ce in the framework, the mesoporous range is lower compared to NA catalyst. In NCZA

  12. Spacecraft Conceptual Design for the 8-Meter Advanced Technology Large Aperture Space Telescope (ATLAST)

    Science.gov (United States)

    Hopkins, Randall C.; Capizzo, Peter; Fincher, Sharon; Hornsby, Linda S.; Jones, David

    2010-01-01

    The Advanced Concepts Office at Marshall Space Flight Center completed a brief spacecraft design study for the 8-meter monolithic Advanced Technology Large Aperture Space Telescope (ATLAST-8m). This spacecraft concept provides all power, communication, telemetry, avionics, guidance and control, and thermal control for the observatory, and inserts the observatory into a halo orbit about the second Sun-Earth Lagrange point. The multidisciplinary design team created a simple spacecraft design that enables component and science instrument servicing, employs articulating solar panels for help with momentum management, and provides precise pointing control while at the same time fast slewing for the observatory.

  13. Operation of a forced two phase cooling system on a large superconducting magnet

    International Nuclear Information System (INIS)

    Green, M.A.; Burns, W.A.; Eberhard, P.H.; Gibson, G.H.; Pripstein, M.; Ross, R.R.; Smits, R.G.; Taylor, J.D.; Van Slyke, H.

    1980-05-01

    This paper describes the operation of a forced two phase cooling system on a two meter diameter superconducting solenoid. The magnet is a thin high current density superconducting solenoid which is cooled by forced two phase helium in tubes around the coil. The magnet, which is 2.18 meters in diameter and 3.4 meters long, has a cold mass of 1700 kg. The two phase cooling system contains less than 300 liters of liquid helium, most of which is contained in a control dewar. This paper describes the operating characteristics of the LBL two phase forced cooling system during cooldown and warm up. The paper presents experimental data on operations of the magnet using either a helium pump or the refrigerator compressor to circulate two phase helium through the superconducting coil cooling tubes

  14. Five training sessions improves 3000 meter running performance.

    Science.gov (United States)

    Riiser, A; Ripe, S; Aadland, E

    2015-12-01

    The primary aim of the present study was to evaluate the effect of two weeks of endurance training on 3000-meter running performance. Secondary we wanted to assess the relationship between baseline running performance and change in running performance over the intervention period. We assigned 36 military recruits to a training group (N.=28) and a control group. The training group was randomly allocated to one of three sub-groups: 1) a 3000 meter group (test race); 2) a 4x4-minutes high-intensity interval group; 3) a continuous training group. The training group exercised five times over a two-week period. The training group improved its 3000 meter running performance with 50 seconds (6%) compared to the control group (P=0.003). Moreover, all sub-groups improved their performance by 37 to 73 seconds (4-8%) compared to the control group (Ptraining group. We conclude that five endurance training sessions improved 3000 meter running performance and the slowest runners achieved the greatest improvement in running performance.

  15. MEASURED DIAMETERS OF TWO F STARS IN THE β PIC MOVING GROUP

    International Nuclear Information System (INIS)

    Simon, M.; Schaefer, G. H.

    2011-01-01

    We report angular diameters of HIP 560 and HIP 21547, two F spectral-type pre-main-sequence members of the β Pic Moving Group. We used the east-west 314 m long baseline of the CHARA Array. The measured limb-darkened angular diameters of HIP 560 and HIP 21547 are 0.492 ± 0.032 and 0.518 ± 0.009 mas, respectively. The corresponding stellar radii are 2.1 and 1.6 R ☉ for HIP 560 and HIP 21547, respectively. These values indicate that the stars are truly young. Analyses using the evolutionary tracks calculated by Siess, Dufour, and Forestini and the tracks of the Yonsei-Yale group yield consistent results. Analyzing the measurements on an angular diameter versus color diagram we find that the ages of the two stars are indistinguishable; their average value is 13 ± 2 Myr. The masses of HIP 560 and HIP 21547 are 1.65 ± 0.02 and 1.75 ± 0.05 M ☉ , respectively. However, analysis of the stellar parameters on a Hertzsprung-Russell diagram yields ages at least 5 Myr older. Both stars are rapid rotators. The discrepancy between the two types of analyses has a natural explanation in gravitational darkening. Stellar oblateness, however, does not affect our measurements of angular diameters.

  16. Two-Dimensional Key Table-Based Group Key Distribution in Advanced Metering Infrastructure

    Directory of Open Access Journals (Sweden)

    Woong Go

    2014-01-01

    Full Text Available A smart grid provides two-way communication by using the information and communication technology. In order to establish two-way communication, the advanced metering infrastructure (AMI is used in the smart grid as the core infrastructure. This infrastructure consists of smart meters, data collection units, maintenance data management systems, and so on. However, potential security problems of the AMI increase owing to the application of the public network. This is because the transmitted information is electricity consumption data for charging. Thus, in order to establish a secure connection to transmit electricity consumption data, encryption is necessary, for which key distribution is required. Further, a group key is more efficient than a pairwise key in the hierarchical structure of the AMI. Therefore, we propose a group key distribution scheme using a two-dimensional key table through the analysis result of the sensor network group key distribution scheme. The proposed scheme has three phases: group key predistribution, selection of group key generation element, and generation of group key.

  17. Disease - MicrobeDB.jp | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...File name: disease.tar.gz File URL: ftp://ftp.biosciencedbc.jp/archive/microbedb/...iption Download License Update History of This Database Site Policy | Contact Us Disease - MicrobeDB.jp | LSDB Archive ...

  18. Close Binary Star Speckle Interferometry on the McMath-Pierce 0.8-Meter Solar Telescope

    Science.gov (United States)

    Wiley, Edward; Harshaw, Richard; Jones, Gregory; Branston, Detrick; Boyce, Patrick; Rowe, David; Ridgely, John; Estrada, Reed; Genet, Russell

    2015-09-01

    Observations were made in April 2014 to assess the utility of the 0.8-meter solar telescope at the McMath-Pierce Solar Observatory at Kitt Peak National Observatory for performing speckle interferometry observations of close binary stars. Several configurations using science cameras, acquisition cameras, eyepieces, and flip mirrors were evaluated. Speckle images were obtained and recommendations for further improvement of the acquisition system are presented.

  19. Ortholog - MicrobeDB.jp | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available List Contact us MicrobeDB.jp Ortholog Data detail Data name Ortholog DOI 10.18908/lsdba.nbdc01181-010.V002 V...814 triples - About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Ortholog - MicrobeDB.jp | LSDB Archive ...

  20. 76 FR 39447 - J.P. Morgan Securities LLC, et al.; Notice of Application and Temporary Order

    Science.gov (United States)

    2011-07-06

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. IC-29711; File No. 812-13914] J.P. Morgan... injunction entered against J.P. Morgan Securities LLC (``J.P. Morgan Securities'') on June 29, 2011 by the... order. Applicants: J.P. Morgan Securities; Bear Stearns Asset Management Inc. (``BSAM''); Bear Stearns...

  1. Effect of airstream velocity on mean drop diameters of water sprays produced by pressure and air atomizing nozzles

    Science.gov (United States)

    Ingebo, R. D.

    1977-01-01

    A scanning radiometer was used to determine the effect of airstream velocity on the mean drop diameter of water sprays produced by pressure atomizing and air atomizing fuel nozzles used in previous combustion studies. Increasing airstream velocity from 23 to 53.4 meters per second reduced the Sauter mean diameter by approximately 50 percent with both types of fuel nozzles. The use of a sonic cup attached to the tip of an air assist nozzle reduced the Sauter mean diameter by approximately 40 percent. Test conditions included airstream velocities of 23 to 53.4 meters per second at 293 K and atmospheric pressure.

  2. TRL Assessment of Solar Sail Technology Development Following the 20-Meter System Ground Demonstrator Hardware Testing

    Science.gov (United States)

    Young, Roy M.; Adams, Charles L.

    2010-01-01

    The NASA In-Space Propulsion Technology (ISPT) Projects Office sponsored two separate, independent solar sail system design and development demonstration activities during 2002-2005. ATK Space Systems of Goleta, CA was the prime contractor for one development team and L' Garde, Inc. of Tustin, CA was the prime contractor for the other development team. The goal of these activities was to advance the technology readiness level (TRL) of solar sail propulsion from 3 towards 6 by the year 2006. Component and subsystem fabrication and testing were completed successfully, including the ground deployment of 10-meter and 20-meter demonstration hardware systems under vacuum conditions. The deployment and structural testing of the 20-meter solar sail systems was conducted in the 30 meter diameter Space Power Facility thermal-vacuum chamber at NASA Glenn Plum Brook in April though August, 2005. This paper will present the results of the TRL assessment following the solar sail technology development activities associated with the design, development, analysis and testing of the 20-meter system ground demonstrators.

  3. Correlations between some physiographic factors and diameter, height and cone characteristics in stone pine (Pinus pinea L. afforestation areas in Balıkesir-Burhaniye region

    Directory of Open Access Journals (Sweden)

    Ali Ömer Üçler

    2017-11-01

    Full Text Available In this study, effects of some physiographic factors (aspect, slope and elevation on breast diameter, height and cone properties (cone weight, number of cones, cone width and cone length in stone pine (Pinus pinea L. afforestation areas in Balıkesir-Burhaniye region were investigated. To determine to effects of physiographic conditions, study area is separated according to aspect, slope and elevation groups. Aspect is separated two groups which are shady aspect (B1 and sunny aspect (B2. Slope is separated two groups which are small from 36 percent (E1 and big from 36 percent (E2. Elevation also is separated two groups which are under 400 meters (Y1 and over 400 meters (Y2. Sample areas were scattering to land classifications by using Stratified Sampling Method. Thus, each aspect, slope and elevation classifications were obtained from sample area where are provided from 32 different areas. Tree heights, the diameter at breast height and cone number were measured on saplings. In addition, in each sample area five Pinus pinea trees were selected. It was measured cone diameter, cone height and air-dries weight values of cones which are picked from selecting trees. According to statistical analysis results, aspect effects to tree heights, cone number and cone weight; slope effects the diameter at breast height, cone number and cone diameter; elevation effects the diameter at breast height, tree height, cone number and cone weight. In terms of tree height and diameter values; the highest average breast height diameter was found in the B1E1Y1 with 13.6 cm, and the highest average height value was found in the B2E2Y2 by interaction. In terms of cone characteristics; with the highest average cone number of 8.5 in B1E1Y1, the highest mean cone weight in B1E1Y1 with 232 gr and the highest cone diameter in B2E2Y1 with 5.4 cm. According to the results of correlation analysis; it was determined that slope and elevation factors have positive effect on breast

  4. Analysis of JP-10 Combustion Mechanism Based on Bimolecular Reaction Collision Model%气体介质中 JP-10液滴蒸发数值模拟研究

    Institute of Scientific and Technical Information of China (English)

    袁嵩; 于亮; 赵汝岩

    2016-01-01

    为了进一步了解 JP-10燃料在航空发动机燃烧室中的蒸发燃烧机理,基于 SRK 状态方程,运用数学建模的方法,对 JP-10液滴蒸发过程进行了数值模拟并分析了环境因素对液滴蒸发表面温度变化及液滴生存时间变化的影响。研究表明,气体介质与液滴间的相对速度和环境压力及温度对 JP-10液滴蒸发湿球温度、升温过程及生存时间影响明显。%In order to further understand the evaporation and combustion mechanism of the JP-10 droplet in the engine combustion chamber,based on the SRK state equation,and by means of mathematical modeling,we simulated the evaporation process of the JP-10 droplet and analyzed the influences of environmental factors on the droplet surface temperature and life time.The results show that the influences of ambient pressure and temperature and relative velocity between gas and droplet on the JP-10 evaporation wet-bulb temperature,heating process and survival time are obvious.

  5. Test Record of Flight Tests Using Alcohol-to-Jet/JP-8 Blended Fuel

    Science.gov (United States)

    2015-09-01

    dual-piloted, twin-engine, turbine -powered, single main rotor helicopter manufactured by the Sikorsky Aircraft Corporation of United Technologies...addition to fuel flow metering, the HMU positions the VG actuator link through a hydraulic piston extending from the left side of the HMU. The VG... turbine -engine, tandem-rotor helicopter designed for transportation of cargo, troops, and weapons during day and night, visual and instrument

  6. BRC - MicrobeDB.jp | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...table). Data file File name: brc.tar.gz File URL: ftp://ftp.biosciencedbc.jp/archive/microbedb/LATEST/brc.ta...rains in JCM. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us BRC - MicrobeDB.jp | LSDB Archive ...

  7. SRA - MicrobeDB.jp | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...e following table). Data file File name: sra.tar.gz File URL: ftp://ftp.biosciencedbc.jp/archive/microbedb/L...t This Database Database Description Download License Update History of This Database Site Policy | Contact Us SRA - MicrobeDB.jp | LSDB Archive ...

  8. A neutron dose equivalent meter at CAEP

    International Nuclear Information System (INIS)

    Tian Shihai; Lu Yan; Wang Heyi; Yuan Yonggang; Chen Xu

    2012-01-01

    The measurement of neutron dose equivalent has been a widespread need in industry and research. In this paper, aimed at improving the accuracy of neutron dose equivalent meter: a neutron dose counter is simulated with MCNP5, and the energy response curve is optimized. The results show that the energy response factor is from 0.2 to 1.8 for neutrons in the energy range of 2.53×10 -8 MeV to 10 MeV Compared with other related meters, it turns that the design of this meter is right. (authors)

  9. Lock-on characteristics behind two side-by-side cylinders of diameter ratio two at small gap ratio

    Science.gov (United States)

    Lee, Petry Y. R.; Lu, Wei-Ting; Chou, Shy-Tsin; Kuo, Cheng-Hsiung

    2012-10-01

    The lock-on characteristics, the detailed interactions and downstream evolutions of the wakes behind side-by-side cylinders of unequal diameter ( D/ d = 2), spaced by a gap ratio 0.75 ( G/ D = 0.75), are investigated at Reynolds number 600 by the dye flow visualization, laser Doppler anemometry (LDA) and particle image velocimeter (PIV) velocity measurements. The lock-on frequency bands are studied by LDA and PIV at Reynolds number 2,000. The D, d and G are the diameters of the large, the small cylinders and the net gap between two cylinders, respectively. Periodic excitations, in form of rotary oscillation about the cylinder center, are applied to the large cylinder with the same amplitude. It is found that while the large cylinder is excited, two lock-on frequency bands of the wake behind the large cylinder are detected. These two lock-on frequency bands correspond to the primary and the one-third sub-harmonic lock-on of the wake behind large cylinder, respectively. These two lock-on frequency bands distribute symmetrically about the fundamental and the third superharmonic of the natural shedding frequency behind a single cylinder at the same Reynolds number. The left-shifted frequency band (1.8 ≤ f e / f os ≤ 2.0) is not considered as a locked-on frequency band because the phase difference between two excitation frequencies across f e / f os = 2.0 vary significantly. While the wake behind the large cylinder is locked-on at f e /3 (or f os ), the gap flow becomes unbiased and the frequency of the wake behind small cylinder remains around the natural shedding frequency. Thus, the frequency band of 3.0 ≤ f e / f os ≤ 3.22 is also not locked-on because the phase difference in the narrow wake excited at f e / f os = 2.93 and 3.07 changes significantly. Note f e and f os denote the excitation frequency and the natural shedding frequency behind a single large cylinder, respectively.

  10. Lock-on characteristics behind two side-by-side cylinders of diameter ratio two at small gap ratio

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Petry Y.R.; Lu, Wei-Ting; Chou, Shy-Tsin; Kuo, Cheng-Hsiung [National Chung Hsing University, Department of Mechanical Engineering, Taichung (China)

    2012-10-15

    The lock-on characteristics, the detailed interactions and downstream evolutions of the wakes behind side-by-side cylinders of unequal diameter (D/d = 2), spaced by a gap ratio 0.75 (G/D = 0.75), are investigated at Reynolds number 600 by the dye flow visualization, laser Doppler anemometry (LDA) and particle image velocimeter (PIV) velocity measurements. The lock-on frequency bands are studied by LDA and PIV at Reynolds number 2,000. The D, d and G are the diameters of the large, the small cylinders and the net gap between two cylinders, respectively. Periodic excitations, in form of rotary oscillation about the cylinder center, are applied to the large cylinder with the same amplitude. It is found that while the large cylinder is excited, two lock-on frequency bands of the wake behind the large cylinder are detected. These two lock-on frequency bands correspond to the primary and the one-third sub-harmonic lock-on of the wake behind large cylinder, respectively. These two lock-on frequency bands distribute symmetrically about the fundamental and the third superharmonic of the natural shedding frequency behind a single cylinder at the same Reynolds number. The left-shifted frequency band (1.8 {<=} f{sub e} /f{sub os} {<=} 2.0) is not considered as a locked-on frequency band because the phase difference between two excitation frequencies across f{sub e} /f{sub os} = 2.0 vary significantly. While the wake behind the large cylinder is locked-on at f{sub e} /3 (or f{sub os}), the gap flow becomes unbiased and the frequency of the wake behind small cylinder remains around the natural shedding frequency. Thus, the frequency band of 3.0 {<=} f{sub e} /f{sub os} {<=} 3.22 is also not locked-on because the phase difference in the narrow wake excited at f{sub e} /f{sub os} = 2.93 and 3.07 changes significantly. Note f{sub e} and f{sub os} denote the excitation frequency and the natural shedding frequency behind a single large cylinder, respectively. (orig.)

  11. Optical diameters of stars measured with the Mt. Wilson Mark III interferometer

    International Nuclear Information System (INIS)

    Simon, R.S.; Mozurkewich, D.; Johnston, K.J.; Gaume, R.; Hutter, D.J.; Bowers, P.F.; Colavita, M.M.; Shao, M.

    1990-01-01

    Reliable stellar angular diameters can now be determined using the Mark III Optical Interferometer located on Mt. Wilson, California. The Mark III is a Michelson Interferometer capable of measuring the interferometric fringe visibility for stars using interferometer baselines varying from 3 to 31.5 meters in length. Angular diameters measured with the Mark III Optical Interferometer are presented for 12 stars at wavelengths of 450 and 800 nm. 10 refs

  12. Advanced Metering Infrastructure based on Smart Meters

    Science.gov (United States)

    Suzuki, Hiroshi

    By specifically designating penetrations rates of advanced meters and communication technologies, devices and systems, this paper introduces that the penetration of advanced metering is important for the future development of electric power system infrastructure. It examines the state of the technology and the economical benefits of advanced metering. One result of the survey is that advanced metering currently has a penetration of about six percent of total installed electric meters in the United States. Applications to the infrastructure differ by type of organization. Being integrated with emerging communication technologies, smart meters enable several kinds of features such as, not only automatic meter reading but also distribution management control, outage management, remote switching, etc.

  13. Two Versus Three Narrow-Diameter Implants with Locator Attachments Supporting Mandibular Overdentures: A Two-Year Prospective Study

    Directory of Open Access Journals (Sweden)

    Ali M. El-Sheikh

    2012-01-01

    Full Text Available Purpose. To compare treatment outcome (survival rate, condition of hard and soft peri-implant tissues and prosthodontic maintenance requirements of two versus three narrow-diameter bone level implants with Locator attachments supporting mandibular overdentures. Materials and Methods. Twenty completely edentulous patients with atrophic mandibles were treated. Ten patients (Group A were treated with overdentures supported by two narrow (3.3-mm diameter implants (Straumann AG, Basel, Switzerland and ten patients (Group B were treated with overdentures supported by three narrow implants. Locator (Zest Anchors, USA attachments were used for prosthetic anchorage. Standardized clinical and radiographic parameters (survival rate, plaque index, calculus index, gingival index, bleeding index, probing depth and marginal bone loss were evaluated at the time of the completion of the prosthetic treatment (baseline and after 6, 12 and 24 months of functional loading. Prosthodontic maintenance requirements were also scored. Results. Only one implant was lost (Group B during the healing period. There were no significant differences with regards to any of the studied clinical and radiographic parameters between the two groups (>0.05. Few prosthetic complications were recorded. Conclusions. No need to insert more than two narrow-diameter bone level implants with Locator attachments in cases of atrophic mandible to support an overdenture, however, long-term prospective studies are required to support this notion.

  14. 78 FR 3042 - J.P. Morgan Securities LLC, et al.; Notice of Application and Temporary Order

    Science.gov (United States)

    2013-01-15

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. IC-30347; 812-14094] J.P. Morgan Securities LLC... entered against J.P. Morgan Securities LLC (``JPMS''), EMC Mortgage, LLC (``EMC''), Bear Stearns Asset... Inc. (``SACO'') and J.P. Morgan Acceptance Corporation I (``JPMAC'') (together, the ``Defendants'') on...

  15. Diameter effect on critical heat flux

    International Nuclear Information System (INIS)

    Tanase, A.; Cheng, S.C.; Groeneveld, D.C.; Shan, J.Q.

    2009-01-01

    The critical heat flux look-up table (CHF LUT) is widely used to predict CHF for various applications, including design and safety analysis of nuclear reactors. Using the CHF LUT for round tubes having inside diameters different from the reference 8 mm involves conversion of CHF to 8 mm. Different authors [Becker, K.M., 1965. An Analytical and Experimental Study of Burnout Conditions in Vertical Round Ducts, Aktiebolaget Atomenergie Report AE 177, Sweden; Boltenko, E.A., et al., 1989. Effect of tube diameter on CHF at various two phase flow regimes, Report IPE-1989; Biasi, L., Clerici, G.C., Garriba, S., Sala, R., Tozzi, A., 1967. Studies on Burnout, Part 3, Energia Nucleare, vol. 14, pp. 530-536; Groeneveld, D.C., Cheng, S.C., Doan, T., 1986. AECL-UO critical heat flux look-up table. Heat Transfer Eng., 7, 46-62; Groeneveld et al., 1996; Hall, D.D., Mudawar, I., 2000. Critical heat flux for water flow in tubes - II subcooled CHF correlations. Int. J. Heat Mass Transfer, 43, 2605-2640; Wong, W.C., 1996. Effect of tube diameter on critical heat flux, MaSC dissertation, Ottawa Carleton Institute for Mechanical and Aeronautical Engineering, University of Ottawa] have proposed several types of correlations or factors to describe the diameter effect on CHF. The present work describes the derivation of new diameter correction factor and compares it with several existing prediction methods

  16. Evaluating the student activity meter : two case studies

    NARCIS (Netherlands)

    Govaerts, S.; Verbert, K.; Duval, E.

    2011-01-01

    In the Technology Enhanced Learning (TEL) domain, visualizations are attracting increased interest. In this paper, we present the Student Activity Meter that visualizes learner activities within online learning environments for learners and teachers to help increase awareness and to support

  17. Failure Diameter Resolution Study

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-19

    Previously the SURFplus reactive burn model was calibrated for the TATB based explosive PBX 9502. The calibration was based on fitting Pop plot data, the failure diameter and the limiting detonation speed, and curvature effect data for small curvature. The model failure diameter is determined utilizing 2-D simulations of an unconfined rate stick to find the minimum diameter for which a detonation wave propagates. Here we examine the effect of mesh resolution on an unconfined rate stick with a diameter (10mm) slightly greater than the measured failure diameter (8 to 9 mm).

  18. Hydrogen meter prooftesting

    International Nuclear Information System (INIS)

    McCown, J.J.; Mettler, G.W.

    1976-04-01

    Two diffusion type hydrogen meters have been tested on the Prototype Applications Loop (PAL). The ANL designed unit was used to monitor hydrogen in sodium during FFTF startup and over a wide range of hydrogen concentrations resulting from chemical additions to the sodium and cover gas. A commercially available meter was added and its performance compared with the ANL unit. Details of the test work are described

  19. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Inspiratory airway pressure meter. 868.1780 Section 868.1780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the amount...

  20. Look at the Beat, Feel the Meter: Top-Down Effects of Meter Induction on Auditory and Visual Modalities.

    Science.gov (United States)

    Celma-Miralles, Alexandre; de Menezes, Robert F; Toro, Juan M

    2016-01-01

    Recent research has demonstrated top-down effects on meter induction in the auditory modality. However, little is known about these effects in the visual domain, especially without the involvement of motor acts such as tapping. In the present study, we aim to assess whether the projection of meter on auditory beats is also present in the visual domain. We asked 16 musicians to internally project binary (i.e., a strong-weak pattern) and ternary (i.e., a strong-weak-weak pattern) meter onto separate, but analog, visual and auditory isochronous stimuli. Participants were presented with sequences of tones or blinking circular shapes (i.e., flashes) at 2.4 Hz while their electrophysiological responses were recorded. A frequency analysis of the elicited steady-state evoked potentials allowed us to compare the frequencies of the beat (2.4 Hz), its first harmonic (4.8 Hz), the binary subharmonic (1.2 Hz), and the ternary subharmonic (0.8 Hz) within and across modalities. Taking the amplitude spectra into account, we observed an enhancement of the amplitude at 0.8 Hz in the ternary condition for both modalities, suggesting meter induction across modalities. There was an interaction between modality and voltage at 2.4 and 4.8 Hz. Looking at the power spectra, we also observed significant differences from zero in the auditory, but not in the visual, binary condition at 1.2 Hz. These findings suggest that meter processing is modulated by top-down mechanisms that interact with our perception of rhythmic events and that such modulation can also be found in the visual domain. The reported cross-modal effects of meter may shed light on the origins of our timing mechanisms, partially developed in primates and allowing humans to synchronize across modalities accurately.

  1. Look at the Beat, Feel the Meter: Top–Down Effects of Meter Induction on Auditory and Visual Modalities

    Science.gov (United States)

    Celma-Miralles, Alexandre; de Menezes, Robert F.; Toro, Juan M.

    2016-01-01

    Recent research has demonstrated top–down effects on meter induction in the auditory modality. However, little is known about these effects in the visual domain, especially without the involvement of motor acts such as tapping. In the present study, we aim to assess whether the projection of meter on auditory beats is also present in the visual domain. We asked 16 musicians to internally project binary (i.e., a strong-weak pattern) and ternary (i.e., a strong-weak-weak pattern) meter onto separate, but analog, visual and auditory isochronous stimuli. Participants were presented with sequences of tones or blinking circular shapes (i.e., flashes) at 2.4 Hz while their electrophysiological responses were recorded. A frequency analysis of the elicited steady-state evoked potentials allowed us to compare the frequencies of the beat (2.4 Hz), its first harmonic (4.8 Hz), the binary subharmonic (1.2 Hz), and the ternary subharmonic (0.8 Hz) within and across modalities. Taking the amplitude spectra into account, we observed an enhancement of the amplitude at 0.8 Hz in the ternary condition for both modalities, suggesting meter induction across modalities. There was an interaction between modality and voltage at 2.4 and 4.8 Hz. Looking at the power spectra, we also observed significant differences from zero in the auditory, but not in the visual, binary condition at 1.2 Hz. These findings suggest that meter processing is modulated by top–down mechanisms that interact with our perception of rhythmic events and that such modulation can also be found in the visual domain. The reported cross-modal effects of meter may shed light on the origins of our timing mechanisms, partially developed in primates and allowing humans to synchronize across modalities accurately. PMID:27047358

  2. Look at the Beat, Feel the Meter:Top-down Effects of Meter Induction on Auditory and Visual Modalities

    Directory of Open Access Journals (Sweden)

    Alexandre eCelma-Miralles

    2016-03-01

    Full Text Available Recent research has demonstrated top-down effects on meter induction in the auditory modality. However, little is known about these effects in the visual domain, especially without the involvement of motor acts such as tapping. In the present study, we aim to assess whether the projection of meter on auditory beats is also present in the visual domain. We asked sixteen musicians to internally project binary (i.e. a strong-weak pattern and ternary (i.e. a strong-weak-weak pattern meter onto separate, but analogue, visual and auditory isochronous stimuli. Participants were presented with sequences of tones or blinking circular shapes (i.e. flashes at 2.4 Hz while their electrophysiological responses were recorded. A frequency analysis of the elicited steady-state evoked potentials allowed us to compare the frequencies of the beat (2.4 Hz, its first harmonic (4.8 Hz, the binary subharmonic (1.2 Hz, and ternary subharmonic (0.8 Hz within and across modalities. Taking the amplitude spectra into account, we observed an enhancement of the amplitude at 0.8 Hz in the ternary condition for both modalities, suggesting meter induction across modalities. There was an interaction between modality and voltage at 2.4 and 4.8 Hz. Looking at the power spectra, we also observed significant differences from zero in the auditory, but not in the visual, binary condition at 1.2 Hz. These findings suggest that meter processing is modulated by top-down mechanisms that interact with our perception of rhythmic events and that such modulation can also be found in the visual domain. The reported cross-modal effects of meter may shed light on the origins of our timing mechanisms, partially developed in primates and allowing humans to synchronize across modalities accurately.

  3. Impedance void-meter and neural networks for vertical two-phase flows

    International Nuclear Information System (INIS)

    Mi, Y.; Li, M.; Xiao, Z.; Tsoukalas, L.H.; Ishii, M.

    1998-01-01

    Most two-phase flow measurements, including void fraction measurements, depend on correct flow regime identification. There are two steps towards successful identification of flow regimes: one is to develop a non-intrusive instrument to demonstrate area-averaged void fluctuations, the other to develop a non-linear mapping approach to perform objective identification of flow regimes. A non-intrusive impedance void-meter provides input signals to a neural mapping approach used to identify flow regimes. After training, both supervised and self-organizing neural network learning paradigms performed flow regime identification successfully. The methodology presented holds considerable promise for multiphase flow diagnostic and measurement applications. (author)

  4. Testing of the McMath-Pierce 0.8-Meter East Auxiliary Telescope's Acquisition and Slewing Accuracy

    Science.gov (United States)

    Harshaw, Richard; Ray, Jimmy; Prause, Lori; Douglass, David; Branston, Detrick; Genet, Russell M.

    2015-09-01

    Following mediocre results with pointing tests of the McMath-Pierce 0.8-meter East Auxiliary Telescope in April 2014, a team of astronomers/engineers met again in May 2014 to test other pointing models and assess the telescope's ability to point with enough accuracy to permit the efficient use of speckle interferometry. Results show that accurate collimation is a pre-requisite for such accuracy. Once attained, the telescope performs extremely well.

  5. Cancer-meter: measure and cure.

    Science.gov (United States)

    Kashyap, Sunil Kumar; Sharma, Birendra Kumar; Banerjee, Amitabh

    2017-05-01

    This paper presents a theory and system on "Cancer-Meter'. This idea came through the statement that "cancer is curable if it is measurable". The Cancer-Meter proves that it is possible. This paper proposes the cancer-meter in two ways, theoretical and electronically, as per the measurement and treatment. By the mathematics, first part is defined but the second part is based on computer programming, electrical and electronics. Thus, the cancer-meter is a programmed-electrical-electronic device which measures and cures the cancer both.

  6. Thermal Analysis of the Advanced Technology Large Aperture Space Telescope (ATLAST) 8 Meter Primary Mirror

    Science.gov (United States)

    Hornsby, Linda; Stahl, H. Philip; Hopkins, Randall C.

    2010-01-01

    The Advanced Technology Large Aperture Space Telescope (ATLAST) preliminary design concept consists of an 8 meter diameter monolithic primary mirror enclosed in an insulated, optical tube with stray light baffles and a sunshade. ATLAST will be placed in orbit about the Sun-Earth L2 and will experience constant exposure to the sun. The insulation on the optical tube and sunshade serve to cold bias the telescope which helps to minimize thermal gradients. The primary mirror will be maintained at 280K with an active thermal control system. The geometric model of the primary mirror, optical tube, sun baffles, and sunshade was developed using Thermal Desktop(R) SINDA/FLUINT(R) was used for the thermal analysis and the radiation environment was analyzed using RADCAD(R). A XX node model was executed in order to characterize the static performance and thermal stability of the mirror during maneuvers. This is important because long exposure observations, such as extra-solar terrestrial planet finding and characterization, require a very stable observatory wave front. Steady state thermal analyses served to predict mirror temperatures for several different sun angles. Transient analyses were performed in order to predict thermal time constant of the primary mirror for a 20 degree slew or 30 degree roll maneuver. This paper describes the thermal model and provides details of the geometry, thermo-optical properties, and the environment which influences the thermal performance. All assumptions that were used in the analysis are also documented. Parametric analyses are summarized for design parameters including primary mirror coatings and sunshade configuration. Estimates of mirror heater power requirements are reported. The thermal model demonstrates results for the primary mirror heated from the back side and edges using a heater system with multiple independently controlled zones.

  7. Isolation and characterization of the pesticide-degrading plasmid pJP1 from Alcaligenes paradoxus

    International Nuclear Information System (INIS)

    Fisher, P.R.; Appleton, J.; Pemberton, J.M.

    1978-01-01

    A strain of Alcaligenes paradoxus, unable to degrade phenoxyacetic acid, was shown to degrade two synthetic derivatives of this molecule, the herbicides 2,4-dichlorophenoxyacetic acid and 2-methyl-4-chlorophenoxyacetic acid. The ability to degrade these pesticides is encoded by a 58-megadalton conjugal plasmid, pJP1

  8. Selection of large diameter drills with the aid of a computer, between diesel and electric alternatives for sedimentary mining. Seleccion de perforadoras de gran diametro con ayuda de ordenador, alternativa diesel electrica en mineria sedimentaria

    Energy Technology Data Exchange (ETDEWEB)

    Colomo Gomez, M. (ENCASUR, Ciudad Real (Spain))

    1988-01-01

    The communication develops a rotary drill rig selection study carried out in Mina Emma, ENCASUR Puertollano (Open pit coal mine), for diameters extended from 9 7/8 to 15 inches and bench heights 10, 15 and 20 meters. Since the choice of diameters is in the transition area from diesel to electric machines, the conclusions are specially interesting in making buying decisions of this kind. 6 figs., 6 tabs.

  9. Manufacturing Challenges and Benefits When Scaling the HIAD Stacked-Torus Aeroshell to a 15 Meter Class System

    Science.gov (United States)

    Swanson, G. T.; Cheatwood, F. M.; Johnson, R. K.; Hughes, S. J.; Calomino, A. M.

    2016-01-01

    Over a decade of work has been conducted in the development of NASA's Hypersonic Inflatable Aerodynamic Decelerator (HIAD) deployable aeroshell technology. This effort has included multiple ground test campaigns and flight tests culminating in the HIAD project's second generation (Gen-2) aeroshell system. The HIAD project team has developed, fabricated, and tested stacked-torus inflatable structures (IS) with flexible thermal protection systems (F-TPS) ranging in diameters from 3-6 meters, with cone angles of 60 and 70 degrees. To meet NASA and commercial near-term objectives, the HIAD team must scale the current technology up to 12-15 meters in diameter. Therefore, the HIAD project's experience in scaling the technology has reached a critical juncture. Growing from a 6-meter to a 15-meter class system will introduce many new structural and logistical challenges to an already complicated manufacturing process. Although the general architecture and key aspects of the HIAD design scale well to larger vehicles, details of the technology will need to be reevaluated and possibly redesigned for use in a 15-meter-class HIAD system. These include: layout and size of the structural webbing that transfers load throughout the IS, inflatable gas barrier design, torus diameter and braid construction, internal pressure and inflation line routing, adhesives used for coating and bonding, and F-TPS gore design and seam fabrication. The logistics of fabricating and testing the IS and the F-TPS also become more challenging with increased scale. Compared to the 6-meter aeroshell (the largest HIAD built to date), a 12-meter aeroshell has four times the cross-sectional area, and a 15-meter one has over six times the area. This means that fabrication and test procedures will need to be reexamined to account for the sheer size and weight of the aeroshell components. This will affect a variety of steps in the manufacturing process, such as: stacking the tori during assembly, stitching the

  10. Benefits of Two Turbine Rotor Diameters and Hub Heights in the Same Wind Farm

    Energy Technology Data Exchange (ETDEWEB)

    Dykes, Katherine L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stanley, Andrew P. J. [Brigham Young University; Ning, Andrew [Brigham Young University

    2018-01-12

    Significant turbine-wake interactions greatly reduce power output in a wind farm. If different turbine hub heights and rotor diameters are included in the same wind farm, the wake interference in the farm will be reduced, resulting in a lower cost of energy (COE) than a farm with identical turbines. In this paper, we present a method to model wind farm COE in farms with hub heights and rotor diameters that vary across the wind farm. We also demonstrate how to optimize these wind farms to minimize COE. The results show that COE can be greatly reduced in wind farms with non-homogeneous turbines, especially when the turbines are spaced close together. For a unidirectional wind rose, including different turbine design in the wind farm has a similar decrease in COE to spreading the wind turbines farther apart. When the rotor diameter and hub height of the wind turbines in a farm are optimized uniformly, a COE decrease of 4% to 13% (depending on the grid spacing and wind shear exponent) is achieved compared to the baseline. When the rotor diameter and turbine heights are optimized non-uniformly, with two different diameters and heights throughout the farm, there is a COE decrease of 22% to 41% compared to the baseline. For a more spread wind rose with a dominant probability from the west, there is a COE decrease between 3% and 10% for uniformly optimized rotor diameter and height compared to the baseline. With two optimized rotor diameters and heights through the farm, a COE decrease of 3% to 19% is achieved. For a similar wind rose shifted such that the dominant wind direction is from the northwest, a COE decrease between 3% and 10% results from uniformly optimized wind turbines compared to the baseline. A COE decrease of 3% to 17% compared to the baseline occurs with two different turbines are optimized throughout the wind farm.

  11. Biodegradation of Jet Fuel-4 (JP-4) in Sequencing Batch Reactors

    Science.gov (United States)

    1992-06-01

    nalw~eo %CUMENTATION PAGE__ _ _ _ _ _ _ _ _O 74S Ab -A258 020 L AW POi~W6 DATI .~ TYP AIMqm ,-& 0 U. glbs A~ I ma"&LFUN Mu BIODEGRADATION OF JET FUEL...Specific Objectives of This Proposal Are: 1. To assess the ability of C. resinae , P. chrysosporium and selected bacterial consortia to degrade individual...chemical components of JP-4. 2. To develop a sequencing batch reactor that utilizes C. resinae to degrade chemical components of JP-4 in contaminated

  12. Developing an equitable fee structure for gas processing services: JP-90 and beyond

    International Nuclear Information System (INIS)

    Kingsbury, J.D.; Moller, I.

    1996-01-01

    The Joint Industry Gas Processing Fee Task Force Report, JP-90, was designed to promote negotiation of gas processing fees that are based on principles of equity and fairness for both natural gas producers and processors. Another purpose of the JP-90 was to develop an effective dispute resolution process for use in those cases where negotiations have failed. At its inception, JP-90 was the only guideline for unregulated fee practices in the oil and gas sector in North America. Today PJVA-95, the revised version of JP-90, is in its final draft. It addresses the changing focus of the gas processing business, and changing regulatory roles in Alberta and British Columbia. A number of other fee mechanisms also have been described, such as the jumping pound formula, fixed fees, fees based on price, wellhead purchases, and others. These mechanisms developed over time to allow the processor and the producer to share the price risk. The changing role of regulatory agencies in fee dispute resolution was also discussed briefly

  13. 77 FR 59184 - J.P. Morgan Ventures Energy Corporation; Notice of Initiation of Proceeding and Refund Effective...

    Science.gov (United States)

    2012-09-26

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL12-103-000] J.P. Morgan... statements by J.P. Morgan Ventures Energy Corporation constitute violations of section 35.41(b) of the Commission's regulations under the Federal Power Act (FPA).\\1\\ J.P. Morgan Ventures Energy Corporation, 140...

  14. Characteristics and calibration of the transmission-type fast neutron moisture meter

    International Nuclear Information System (INIS)

    Banzai, K.

    1984-01-01

    With the Transmission-type Fast Neutron Moisture Meter, we did some experiments for calibration and the effective range of fast neutron scattering, and observed soil moisture process before and after making artificial rainfall at a lysimeter filled by decomposed granite. A fast neutron source of this meter is 252 Cf and capacity of 100 μ Ci. The neutron detector is NE-213 liquid scintilator which recovers a little flux of neutron source. For the customary thermal neutron meter, the effective range of neutron scattering is variable by soil moisture values surrounding the observation point, but this fast neutron, insert and transmission-type meter shows soil moisture in small capacity between a source and a detector. Experimental Results; 1) The calibration curve, calculated statistically from the relation of soil moisture and the count ratio in a 200 l drum packed with beads, gravel, sand and Kanto loam, became only one line. The correlation coefficient of this curve was 0.996 and the standard error was 1.94% with volumetric water content. 2) Count ratio started to decrease as observation point approached soil surface from the boundary of 6 cm depth in soil. Volumetric water content increased more than fact with the previous calibration curve. 3) We limited the detectable range to fast neutron, but a little scattering was seen surrounding the soil of a observation point. The effective range of horizontal scattering was a width of 20 cm with the center line connected between a source and a detector, with a circle of 5 cm diameter surrounding the source, and a circle of 10-15 cm diameter surrounding the detector. 4) Soil moisture before and after artificial rainfall was observed with this meter and by the measurement of a 100 cm 3 oven dried sampling vessel. Volumetric water content by the latter measurement, was more variable because sampling points were at a distance from the center of observation site and sampling technique was bad. Otherwise soil moisture values

  15. Characteristic tests of ionization chamber and GM counter survey meters for beta-rays, (2)

    International Nuclear Information System (INIS)

    Suga, Shin-ichi; Bingo, Kazuyoshi; Kajimoto, Yoichi

    1979-03-01

    To estimate a beta-ray absorbed dose rate of contaminated skin, measurements were done twice by a survey meter without and with a filter, keeping the distance from the contaminated skin surface to the survey meter at 10 mm. The absorbed dose rate was obtained multiplying a net reading (equals a reading of survey meter's indicator measured without the filter minus that measured with the filter) by a multiplying factor. Calibrations were made with reference plane sources of natural uranium, 198 Au and 204 Tl, varying their area. The five types of ionization chamber survey meters had nearly same multiplying factors when the diameter of source was larger than the diameter of the chamber cylinder. Estimation of the absorbed doses due to beta-emitting nuclides was possible when the measured value without filter was larger by 20% or more than that of with filter. In the case of small sources, the multiplying factor varied significantly with area of the source. The multiplying factors agreed within +-30% in the respective types i.e. manufacturers and in maximum beta-ray energies from 0.7 up to 2.5 MeV. In the source to detector distance of 1 cm +-0.2 cm, the multiplying factor varied within +-20%. The multiplying factor of a GM counter survey meter varied with beta-ray energy, the multiplying factor for uranium was 1/3 that of 204 Tl. (author)

  16. 21 CFR 868.1860 - Peak-flow meter for spirometry.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Peak-flow meter for spirometry. 868.1860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1860 Peak-flow meter for spirometry. (a) Identification. A peak-flow meter for spirometry is a device used to measure a patient's...

  17. Aerodynamic effect of a honeycomb rotor tip shroud on a 50.8-centimeter-tip-diameter core turbine

    Science.gov (United States)

    Moffitt, T. P.; Whitney, W. J.

    1983-01-01

    A 50.8-cm-tip-diameter turbine equipped with a rotor tip shroud of hexagonal cell (or honeycomb) cross section has been tested in warm air (416 K) for a range of shroud coolant to primary flow rates. Test results were also obtained for the same turbine operated with a solid shroud for comparison. The results showed that the combined effect of the honeycomb shroud and the coolant flow was to cause a reduction of 2.8 points in efficiency at design speed, pressure ratio, and coolant flow rate. With the coolant system inactivated, the honeycomb shroud caused a decrease in efficiency of 2.3 points. These results and those obtained from a small reference turbine indicate that the dominant factor governing honeycomb tip shroud loss is the ratio of honeycomb depth to blade span. The loss results of the two shrouds could be correlated on this basis. The same honeycomb and coolant effects are expected to occur for the hot (2200 K) version of this turbine.

  18. Performance testing of Tesla NNG 601 activity meter in nuclear medicine department

    International Nuclear Information System (INIS)

    Husak, V.; Kleinbauer, K.

    1980-01-01

    The results are presented of testing activity meter Tesla NNG 601 the production of which began in Czechoslovakia in 1978. The meter is provided with a shielded well-type ionization chamber, the well 42 mm in diameter and 140 mm deep. The parameters of the instrument linearity, volume dependence, accuracy and stability, correctness of calibration were compared with those of other instruments (Searle Analytic, Picker and Capinted). The volume dependence of the Czechoslovak NNG 601 instrument is higher than that in the other instruments, other parameters are the same of better

  19. Metering Plan: Intelligent Operational Strategies Through Enhanced Metering Systems

    Energy Technology Data Exchange (ETDEWEB)

    Pope, Jason E.

    2016-07-27

    The Sustainability Program at Pacific Northwest National Laboratory (PNNL) has adopted a “triple-bottom-line” approach of environmental stewardship, social responsibility, and economic prosperity to its operations. Metering at PNNL works in support of all three, specifically to measure and inform building energy use and greenhouse gas emissions and minimize water use. The foundation for metering at PNNL is a core goal set, which consists of four objectives: providing accurate data without interruption, analyzing data while it is still new, providing actionable recommendations to operations management, and ensuring PNNL’s compliance with contract metering requirements. These core objectives guide the decisions that we make during annual planning and as we operate throughout the year. This 2016 edition of the Metering Plan conveys the metering practices for and vision of the Sustainability Program. Changes in this plan from the 2015 edition include updated tables and an enhanced discussion on energy tracking systems used at PNNL. This plan also discusses updated benchmarking strategies using PNNL’s graphics and analytics tool, BuildingOS by Lucid Design Group. This plan presents our progress toward the metering goals shared by all federal agencies and highlights our successful completion of metering requirements. Currently, PNNL is fully compliant with the applicable legislative and Executive Order metering requirements. PNNL’s approach to the installation of new meters will be discussed. Perhaps most importantly, this plan details the analysis techniques utilized at PNNL that rely on the endless streams of data newly available as a result of increased meter deployment over the last several years. Previous Metering Plans have documented specific meter connection schemes as PNNL focused on deploying meters in a first step toward managing energy and water use. This plan serves not only to highlight PNNL’s successful completion of agency metering goals, but

  20. Measuring methods in power metering 2013; Elektrizitaetsmesstechnik 2013

    Energy Technology Data Exchange (ETDEWEB)

    Kahmann, Martin; Zayer, Peter (eds.)

    2012-07-01

    The book addresses technical and economic issues of power metering, data communication and data processing. Smart metering is the key issue discussed in all 14 contributions: 1. The perspective of Smart Metering in Europe through 2020; 2. Introduction of Smart Metering in Austria; 3. Metering after the amended EnWG 2011; 4. The FNN project ''MessSystem 2020''; 5. Technological requirements of Smart Grid and Smart Market; 6. DIN Spec 33440 ''Ergonomic Aspects of Smart Grids and Electromobility''; 7. Load management as a key element of energy transition; 8. Added value in Smart Metering as a result of Smart Home applications, 9. The main cost factors of the new metering systems; 10. BSI protection profile: Smart Meter Gateway certification; 11. The influence of new boundary conditions in metering on intercompany processes; 12. Reliable time allotment via internet; 13. Recommendations of the EEG Clearing Authority on metering problems; 14. Outline quality management manual for state-authorized test services for electric power, gas, water, and heat. [German] Dieses Buch richtet seinen Blick sowohl auf technische wie auch auf energiewirtschaftliche Themen rund um das Thema Mess- und Zaehltechnik sowie die inzwischen immer bedeutsamer werdende zugehoerige Datenkommunikations- und Datenverarbeitungstechnik. Eine zunehmende Betrachtung des Smart Metering als einen Teilaspekt des grossen Themas Smart Grid bildet die gemeinsame Klammer um die Beitraege. Die Themen der 14 Beitraege sind: 1. Perspektive Smart Metering in Europa bis 2020; 2. Smart-Meter-Einfuehrung in Oesterreich; 3. Das Messwesen nach der EnWG-Novelle 2011; 4. Das FNN-Projekt ''MessSystem 2020''; 5. Anforderungen durch Smart Grid und Smart Market an die intelligente Messtechnik; 6. DIN Spec 33440 ''Ergonomie-Aspekte zu Smart Grid und Elektromobilitaet''; 7. Lastverschiebung als Baustein der Energiewende; 8. Mehrwerte beim Smart

  1. The design and application of virtual ion meter based on LABVIEW 8.0.

    Science.gov (United States)

    Meng, Hu; Li, Jiangyuan; Tang, Yonghuai

    2009-08-01

    The virtual ion meter is developed based on LABVIEW 8.0 by homemade adjusting circuit, data acquisition (DAQ) board, and computer. This note provides details of the structure of testing system and flow chart of DAQ program. This virtual instrument system is applied to multitask testing such as determining rate constant of second-order reaction by pX, pX potentiometric titration, determining oscillating reaction by potential, etc. The result of application indicates that this test system not only has function of real-time data acquiring, displaying, storage, but also realizes remote monitoring and controlling test-control spots through internet, automatic analyzing and processing of data, reporting of result according to the different testing task; moreover, the veracity and repeatability of data processing result are higher than the results of manual data processing.

  2. Measuring set: Reactor Power Meter (type of SG-8), Reactor Energy Meter (type of SG-11) and Digital Dose Meter (type of SG-9) for reactor rigs operation. Zestaw pomiarowy: miernik mocy reaktora (typ SG-8), miernik energii reaktora (typ SG-11) oraz cyfrowy miernik dawki (typ SG-9) dla potrzeb eksploatacji sond reaktorowych

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W

    1982-01-01

    A measuring set consisting of the Reactor Power Meter, Reactor Energy Meter and Digital Dose Meter is described. The gamma radiation of water in the reactor primary cooling circuit reaches the ionisation chamber and involves the output current, driving the Reactor Power Meter and Reactor Energy Meter. The Digital Dose Meter is controlled by the output current of the self-powered detector mounted inside the reactor rig.

  3. Pathogenicity of the highly leukotoxic JP2 clone of Aggregatibacter actinomycetemcomitans and its geographic dissemination and role in aggressive periodontitis

    Directory of Open Access Journals (Sweden)

    Dorte Haubek

    2014-08-01

    Full Text Available For decades, Aggregatibacter actinomycetemcomitans has been associated with aggressive forms of periodontitis in adolescents. In the middle of the 1990s, a specific JP2 clone of A. actinomycetemcomitans, belonging to the cluster of serotype b strains of A. actinomycetemcomitans and having a number of other characteristics, was found to be strongly associated with aggressive forms of periodontitis, particularly in North Africa. Although several longitudinal studies still point to the bacterial species, A. actinomycetemcomitans as a risk factor of aggressive periodontitis, it is now also widely accepted that the highly leukotoxic JP2 clone of A. actinomycetemcomitans is implicated in rapidly progressing forms of aggressive periodontitis. The JP2 clone strains are highly prevalent in human populations living in Northern and Western parts of Africa. These strains are also prevalent in geographically widespread populations that have originated from the Northwest Africa. Only sporadic signs of a dissemination of the JP2 clone strains to non-African populations have been found despite Africans living geographically widespread for hundreds of years. It remains an unanswered question if a particular host tropism exists as a possible explanation for the frequent colonization of the Northwest African population with the JP2 clone. Two exotoxins of A. actinomycetemcomitans are known, leukotoxin (LtxA and cytolethal distending toxin (Cdt. LtxA is able to kill human immune cells, and Cdt can block cell cycle progression in eukaryotic cells and thus induce cell cycle arrest. Whereas the leukotoxin production is enhanced in JP2 clone strains thus increasing the virulence potential of A. actinomycetemcomitans, it has not been possible so far to demonstrate such a role for Cdt. Lines of evidence have led to the understanding of the highly leukotoxic JP2 clone of A. actinomycetemcomitans as an aetiological factor of aggressive periodontitis. Patients, who are

  4. Pathogenicity of the highly leukotoxic JP2 clone of Aggregatibacter actinomycetemcomitans and its geographic dissemination and role in aggressive periodontitis

    Science.gov (United States)

    Haubek, Dorte; Johansson, Anders

    2014-01-01

    For decades, Aggregatibacter actinomycetemcomitans has been associated with aggressive forms of periodontitis in adolescents. In the middle of the 1990s, a specific JP2 clone of A. actinomycetemcomitans, belonging to the cluster of serotype b strains of A. actinomycetemcomitans and having a number of other characteristics, was found to be strongly associated with aggressive forms of periodontitis, particularly in North Africa. Although several longitudinal studies still point to the bacterial species, A. actinomycetemcomitans as a risk factor of aggressive periodontitis, it is now also widely accepted that the highly leukotoxic JP2 clone of A. actinomycetemcomitans is implicated in rapidly progressing forms of aggressive periodontitis. The JP2 clone strains are highly prevalent in human populations living in Northern and Western parts of Africa. These strains are also prevalent in geographically widespread populations that have originated from the Northwest Africa. Only sporadic signs of a dissemination of the JP2 clone strains to non-African populations have been found despite Africans living geographically widespread for hundreds of years. It remains an unanswered question if a particular host tropism exists as a possible explanation for the frequent colonization of the Northwest African population with the JP2 clone. Two exotoxins of A. actinomycetemcomitans are known, leukotoxin (LtxA) and cytolethal distending toxin (Cdt). LtxA is able to kill human immune cells, and Cdt can block cell cycle progression in eukaryotic cells and thus induce cell cycle arrest. Whereas the leukotoxin production is enhanced in JP2 clone strains thus increasing the virulence potential of A. actinomycetemcomitans, it has not been possible so far to demonstrate such a role for Cdt. Lines of evidence have led to the understanding of the highly leukotoxic JP2 clone of A. actinomycetemcomitans as an aetiological factor of aggressive periodontitis. Patients, who are colonized with the JP2

  5. Properties of cellulose triacetate dose meter

    International Nuclear Information System (INIS)

    Tamura, N.; Tanaka, R.; Mitomo, S.; Matsuda, K.; Nagai, S.

    1981-01-01

    Several clear plastics and dyed plastics are commercially available for dosimetry in intense radiation field, especially for radiation processing applications. Among these dose meters cellulose triacetate (CTA) dose meter has two advantages for routine uses; (1) it has linear response in mega-rad dose region and (2) the main product form is long tape. However, the manufacture of Numelec CTA film so far used had been discontinued, and for this reason we developed a new film for dosimetry uses. To determine the manufacturing conditions of the film, we examined the influence of additives, triphenylphosphate (TPP) and others, and film thickness on the dosimetric properties, since these two conditions remarkably influence the sensitivity of the dose meter. It is necessary for the reliability of plastic dose meters that the radiation induced colorations should be understood as radiation chemical processes. In this paper we describe the determination of the manufacturing conditions of the new film, the feature of the new dose meter, and the coloration mechanism. (author)

  6. Applications of Pitot-meter techniques in two-phase, steam/water, flow

    International Nuclear Information System (INIS)

    Kastner, W.; Manzano-Ruiz, J.J.

    1985-01-01

    A simple technique, based on the interpretation of dynamic-pressure readings obtained with local and averaging Pitot-meters (APM) in tow-phase flow, is described and analyzed. The mean dynamic-pressure measurements obtained with an APM allow the calculation of the mass flux of the mixture if the steam quality is known and a combination of two slip-factor correlations is used. The local dynamic-pressure measurements with a multiple Pitot-probe technique provide information on the transition between the most commonly found flow patterns in horizontal piping, i.e. stratified, annular and annular-mist flow

  7. Experimental test for receiving X-Band data LAPAN-A3 Satellite with 5.4m antenna diameter

    Science.gov (United States)

    Dwi Harsono, Sonny; Hasbi, Wahyudi

    2018-05-01

    LAPAN-A3 / LAPAN-IPB Satellite launched on June 22, 2016 (03:56 UTC) as an experimental micro-satellite for remote sensing and monitoring of maritime traffic. The Satellite was launched as a secondary payload on ISRO Cartosat-2C as its main payload, the launch carried out at SDSC (Satish Dhawan Space Centre) in India using PSLV-C34 rocket launcher. The Satellite was in orbit polar sun-synchronous with a height of 505 km above sea level. It has an inclination angle of 97 degrees and heavy satellite 115 kg, with this orbit, the satellite will pass through Ground station 4 times (2 times during the day and two times at night) with a duration of the track at the time of the pass about 10-15 minutes. The Satellite payload carried 4 bands Line Scan Cameras and Digital Imager (SpaceCam). For main mission is the earth observation for food vegetables And as additional mission is carrying AIS (Automatic Identification System) receiver to monitor maritime traffic in the region of the poles, then Star Sensor made by LAPAN for qualifying room, then for scientific contained magnetometer sensor for monitoring the Earth's Magnetic field. The purpose of this scientific paper is to test the reception of data payloads of the LAPAN-A3 satellite on X-Band frequency of 8.2 GHz using a 5.4 M solid antenna Ground Stations LAPAN in Pare-Pare. The purpose of this experiment will tell us with 5.4 meter of diameter solid antenna is capable or not enough for HDRM receiver to lock a signal and produce the data output, and how this result if compare with 11 meter of diameter antenna in Splitzberg Groundstation in Norway.

  8. Adaptation of the DP 50 dust meter for measuring dust content under isokinetic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Vitek, J.; Novak, L.

    1985-03-01

    The DP 50 dust meter, developed by the Scientific Coal Research Institute Ostrava-Radvanice, is used for measuring dust content in the air in underground coal mines. Two versions of the system are used: a type developed in 1970 which is placed in a vertical position and used to measure the content of respirable coal particles in the air; and a type developed in 1983 for isokinetic measurement of dust content in the air. The latter is equipped with 8 cone-shaped adapters (with differing size and dimensions of the cone inlet adjusted to air flow rates from 0.25 to 8.00 m/s). Specifications of the 8 adapters are given in a table. The 1983 version of the DP 50 is placed in a horizontal position with the dust meter axis parallel to the direction of air flow ventilating a mine working. Recommendations for installation of dust meters in underground workings and effects of installation on measurement accuracy are discussed. 16 references.

  9. Effects of simulated altitude on blood glucose meter performance: implications for in-flight blood glucose monitoring.

    Science.gov (United States)

    Olateju, Tolu; Begley, Joseph; Flanagan, Daniel; Kerr, David

    2012-07-01

    Most manufacturers of blood glucose monitoring equipment do not give advice regarding the use of their meters and strips onboard aircraft, and some airlines have blood glucose testing equipment in the aircraft cabin medical bag. Previous studies using older blood glucose meters (BGMs) have shown conflicting results on the performance of both glucose oxidase (GOX)- and glucose dehydrogenase (GDH)-based meters at high altitude. The aim of our study was to evaluate the performance of four new-generation BGMs at sea level and at a simulated altitude equivalent to that used in the cabin of commercial aircrafts. Blood glucose measurements obtained by two GDH and two GOX BGMs at sea level and simulated altitude of 8000 feet in a hypobaric chamber were compared with measurements obtained using a YSI 2300 blood glucose analyzer as a reference method. Spiked venous blood samples of three different glucose levels were used. The accuracy of each meter was determined by calculating percentage error of each meter compared with the YSI reference and was also assessed against standard International Organization for Standardization (ISO) criteria. Clinical accuracy was evaluated using the consensus error grid method. The percentage (standard deviation) error for GDH meters at sea level and altitude was 13.36% (8.83%; for meter 1) and 12.97% (8.03%; for meter 2) with p = .784, and for GOX meters was 5.88% (7.35%; for meter 3) and 7.38% (6.20%; for meter 4) with p = .187. There was variation in the number of time individual meters met the standard ISO criteria ranging from 72-100%. Results from all four meters at both sea level and simulated altitude fell within zones A and B of the consensus error grid, using YSI as the reference. Overall, at simulated altitude, no differences were observed between the performance of GDH and GOX meters. Overestimation of blood glucose concentration was seen among individual meters evaluated, but none of the results obtained would have resulted in

  10. Numerical study of two side-by-side cylinders with unequal diameters at low Reynolds number

    International Nuclear Information System (INIS)

    Gao, Y Y; Wang, X K; Tan, S K

    2012-01-01

    Two-dimensional laminar flow about two side-by-side unequal cylinders with different diameter ratios d/D and centre-to-centre spacing ratios T/D at Re=300 (based on the larger cylinder diameter) was simulated using a CFD software. Comparisons of experimental and numerical results were made to elucidate the degree of interference due to d/D and T/D and their effects on the flow patterns and vortex shedding frequencies. The findings showed that the flow patterns behind two unequal cylinders were distinctly different from that behind two equal side-by-side cylinders, with distinct in-phase and anti-phase vortex shedding, and random switching of modes of vortex shedding.

  11. Passively Q-switched of EDFL employing multi-walled carbon nanotubes with diameter less than 8 nm as saturable absorber

    Directory of Open Access Journals (Sweden)

    Zuikafly Siti Nur Fatin

    2017-01-01

    Full Text Available The paper demonstrates passively Q-switched erbium-doped fiber laser implementing multiwalled carbon nanotubes (MWCNTs based saturable absorber. The paper is the first to report the use of the MWCNTs with diameter less than 8 nm as typically, the diameter used is 10 to 20 nm. The MWCNTs is incorporated with water soluble host polymer, polyvinyl alcohol (PVA to produce a MWCNTs polymer composite thin film which is then sandwiched between two fiber connectors. The fabricated SA is employed in the laser experimental setup in ring cavity. The Q-switching regime started at threshold pump power of 103 mW and increasable to 215 mW. The stable pulse train from 41.6 kHz to 76.92 kHz with maximum average output power and pulse energy of 0.17 mW and 3.39 nJ are produced. The shortest pulse width of 1.9 μs is obtained in the proposed experimental work, making it the lowest pulse width ever reported using MWCNTs-based saturable absorber.

  12. Digital Receiver Phase Meter

    Science.gov (United States)

    Marcin, Martin; Abramovici, Alexander

    2008-01-01

    The software of a commercially available digital radio receiver has been modified to make the receiver function as a two-channel low-noise phase meter. This phase meter is a prototype in the continuing development of a phase meter for a system in which radiofrequency (RF) signals in the two channels would be outputs of a spaceborne heterodyne laser interferometer for detecting gravitational waves. The frequencies of the signals could include a common Doppler-shift component of as much as 15 MHz. The phase meter is required to measure the relative phases of the signals in the two channels at a sampling rate of 10 Hz at a root power spectral density measurements in laser metrology of moving bodies. To illustrate part of the principle of operation of the phase meter, the figure includes a simplified block diagram of a basic singlechannel digital receiver. The input RF signal is first fed to the input terminal of an analog-to-digital converter (ADC). To prevent aliasing errors in the ADC, the sampling rate must be at least twice the input signal frequency. The sampling rate of the ADC is governed by a sampling clock, which also drives a digital local oscillator (DLO), which is a direct digital frequency synthesizer. The DLO produces samples of sine and cosine signals at a programmed tuning frequency. The sine and cosine samples are mixed with (that is, multiplied by) the samples from the ADC, then low-pass filtered to obtain in-phase (I) and quadrature (Q) signal components. A digital signal processor (DSP) computes the ratio between the Q and I components, computes the phase of the RF signal (relative to that of the DLO signal) as the arctangent of this ratio, and then averages successive such phase values over a time interval specified by the user.

  13. Experiments on hydraulically-compensated Compressed Air Energy Storage (CAES) system using large-diameter vertical pipe two-phase flow test facility: test facility and test procedure

    International Nuclear Information System (INIS)

    Ohtsu, Iwao; Murata, Hideo; Kukita, Yutaka; Kumamaru, Hiroshige.

    1996-07-01

    JAERI, the University of Tokyo, the Central Research Institute of Electric Power Industry and Shimizu Corporation jointing performed and experimental study on two-phase flow in the hydraulically-compensated Compressed Air Energy Storage (CAES) system with a large-diameter vertical pipe two-phase flow test facility from 1993 to 1995. A hydraulically-compensated CAES system is a proposed, conceptual energy storage system where energy is stored in the form of compressed air in an underground cavern which is sealed by a deep (several hundred meters) water shaft. The shaft water head maintains a constant pressure in the cavern, of several mega Pascals, even during loading or unloading of the cavern with air. The dissolved air in the water, however, may create voids in the shaft when the water rises through the shaft during the loading, being forced by the air flow into the cavern. The voids may reduce the effective head of the shaft, and thus the seal may fail, if significant bubbling should occur in the shaft. This bubbling phenomenon (termed 'Champaign effect') and potential failure of the water seal ('blowout') are simulated in a scaled-height, scaled-diameter facility. Carbon dioxide is used to simulate high solubility of air in the full-height, full-pressure system. This report describes the expected and potential two-phase flow phenomena in a hydraulically-compensated CAES system, the test facility and the test procedure, a method to estimate quantities which are not directly measured by using measured quantities and hydrodynamic basic equations, and desirable additional instrumentation. (author)

  14. NEOWISE REACTIVATION MISSION YEAR TWO: ASTEROID DIAMETERS AND ALBEDOS

    Energy Technology Data Exchange (ETDEWEB)

    Nugent, C. R.; Cutri, R. M. [Infrared Processing and Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States); Mainzer, A.; Bauer, J.; Kramer, E. A.; Masiero, J.; Sonnett, S. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Grav, T. [Planetary Science Institute, Tucson, AZ (United States); Wright, E. L., E-mail: cnugent@ipac.caltech.edu [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States)

    2016-09-01

    The Near-Earth Object Wide-Field Infrared Survey Explorer (NEOWISE) mission continues to detect, track, and characterize minor planets. We present diameters and albedos calculated from observations taken during the second year since the spacecraft was reactivated in late 2013. These include 207 near-Earth asteroids (NEAs) and 8885 other asteroids. Of the NEAs, 84% NEAs did not have previously measured diameters and albedos by the NEOWISE mission. Comparison of sizes and albedos calculated from NEOWISE measurements with those measured by occultations, spacecraft, and radar-derived shapes shows accuracy consistent with previous NEOWISE publications. Diameters and albedos fall within ±∼20% and ±∼40%, 1-sigma, respectively, of those measured by these alternate techniques. NEOWISE continues to preferentially discover near-Earth objects which are large (>100 m), and have low albedos.

  15. Analytic evaluation of a new glucose meter system in 15 different critical care settings.

    Science.gov (United States)

    Mitsios, John V; Ashby, Lori A; Haverstick, Doris M; Bruns, David E; Scott, Mitchell G

    2013-09-01

    Maintaining appropriate glycemic control in critically ill patients reduces morbidity and mortality. The use of point-of-care (POC) glucose devices is necessary to obtain rapid results at the patient's bedside. However, the devices should be thoroughly tested in the intended population before implementation. The use of POC glucose meters in critically ill patients has been questioned both in the literature and by regulatory agencies. The aim of this study was to determine if the ACCU-CHEK® Inform II system (Roche Diagnostics) POC glucose meter demonstrated the desired accuracy and precision, as defined by Clinical and Laboratory Standards Institute guideline POCT12-A3, in a large number of critically ill patients from multiple intensive care settings at two academic medical centers. A total of 1200 whole blood meter results from 600 patients were compared with central laboratory plasma values. Whole blood aliquots from venous samples were used to obtain duplicate meter results with the remaining sample being processed to obtain plasma for central laboratory testing within 5 min of meter testing. A total of 1185 (98.8%) of the new meter's glucose values were within ± 12.5% (± 12 mg/dl for values ≥ 100 mg/dl) of the comparative laboratory glucose values, and 1198 (99.8%) were within ± 20% (± 20 mg/dl for values meter system appears to have sufficient analytic accuracy for use in critically ill patients. © 2013 Diabetes Technology Society.

  16. A micro-controller based wide range survey meter

    International Nuclear Information System (INIS)

    Bhingare, R.R.; Bajaj, K.C.; Kannan, S.

    2004-01-01

    Wide range survey meters (1μSv/h -10 Sv/h) with the detector(s) mounted at the end of a two-to-four meter-long extendable tube are widely used for radiation protection survey of difficult to reach locations and high dose rate areas, The commercially available survey meters of this type use two GM counters to cover a wide range of dose rate measurement. A new micro-controller based wide range survey meter using two Si diode detectors has been developed. The use of solid state detectors in the survey meter has a number of advantages like low power consumption, lighter battery powered detector probe, elimination of high voltage for the operation of the detectors, etc. The design uses infrared communication between the probe and the readout unit through a light-weight collapsible extension tube for high reliability. The design details and features are discussed in detail. (author)

  17. Effect of diameter and axial location on upward gas–liquid two-phase flow patterns in intermediate-scale vertical tubes

    International Nuclear Information System (INIS)

    Ansari, M.R.; Azadi, R.

    2016-01-01

    Highlights: • A vertical two-phase flow system is manufactured to study flow behavior adiabatically. • Two test sections are studied with inner diameters of 40 mm and 70 mm at two locations. • Flow pattern maps are presented for both tubes. • Effects of tube diameter and heights on pattern transition boundaries are investigated. • Three sub-patterns bubbly flow and two types of slug pattern are recognized. - Abstract: In the present research, a two-phase flow system is designed, manufactured, assembled and adjusted to study two-phase flow behavior isothermally. Test sections are tubes standing in vertical position and are made of transparent acrylic with inner diameters of 40 mm and 70 mm. Two axial locations of 1.73 m and 3.22 m are chosen for data acquisition. Flow pattern maps are presented for both tubes. Effects of tube diameter and axial location on pattern transition boundaries are investigated. Air and water are chosen as working fluids. The range of air and water superficial velocities are 0.054–9.654 m/s and 0.015–0.877 m/s for the 40 mm diameter tube, but these values are 0.038–20.44 m/s and 0.036–1.530 m/s for 70 mm diameter tube. The results show that for both tubes, increasing axial location does not affect flow transition boundaries significantly. However, slug pattern region shrinks considerably by changing tube diameter from 40 mm to 70 mm. Using image processing techniques, recorded high speed movies were investigated accurately. As a result, bubbly flow in the 40 mm tube can be divided into three sub-patterns as dispersed, agitated and agglomerated bubbly. Also, two types of slug pattern are also recognized in the same tube diameter which are called small and large slugs. Semi-annular flow is observed as an independent pattern in the 70 mm tube that does not behave as known churn or annular patterns.

  18. Smart Metering: Learning from telecommunication providers. Innovative customized products; Beim Smart Metering von Telekommunikationsanbietern lernen. Innovative Buendelprodukte

    Energy Technology Data Exchange (ETDEWEB)

    Isbrecht, Volker; Sombrutzki, Ingo [Putz und Partner Unternehmensberatung AG, Hamburg (Germany). Strategie- und Projektmanagement - Energiewirtschaft; Hofer, Kristina [Putz und Partner Unternehmensberatung AG, Hamburg (Germany). CRM- und Telekommunikation

    2010-04-06

    Deregulation in the electricity and gas metering has raised interest in smart meters. Experts estimate that in a four-person household, smart meters may reduce electricity consumption by up to 10 percent, i.e. 50 - 90 Euros, and CO2 emissions by 8.5 million tonnes, which amounts to 4 percent of the total CO2 emissions in Germany. These are ideal conditions for utilities to develop innovative products for the mass market of private consumers and to improve their competitive standing in the market by a clearly communicated advantage to both the customers and the climate. By utilizing the experience gained in the telecommunications industry, they will be able to respond quickly to impending challenges. (orig.)

  19. Heritability of retinal vessel diameters and blood pressure

    DEFF Research Database (Denmark)

    Taarnhøj, Nina C B B; Larsen, Michael; Sander, Birgit

    2006-01-01

    PURPOSE: To assess the relative influence of genetic and environmental effects on retinal vessel diameters and blood pressure in healthy adults, as well as the possible genetic connection between these two characteristics. METHODS: In 55 monozygotic and 50 dizygotic same-sex healthy twin pairs......%-80%) for CRAE, 83% (95% CI: 73%-89%) for CRVE, and 61% (95% CI: 44%-73%) for mean arterial blood pressure (MABP). Retinal artery diameter decreased with increasing age and increasing arterial blood pressure. Mean vessel diameters in the population were 165.8 +/- 14.9 microm for CRAE, 246.2 +/- 17.7 microm...... for CRVE, and 0.67 +/- 0.05 microm for AVR. No significant influence on artery or vein diameters was found for gender, smoking, body mass index (BMI), total cholesterol, fasting blood glucose, or 2-hour oral glucose tolerance test values. CONCLUSIONS: In healthy young adults with normal blood pressure...

  20. Development of fuel cycles with new fuel with 8.9 mm external diameter for VVER-440. Preliminary assessment of operating efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Gagarinskiy, Alexey [National Research Centre ' ' Kurchatov Institute' ' , Moscow (Russian Federation)

    2017-09-15

    Since the introduction of VVERs-440, their fuel assemblies are subject to ongoing improvements. Until now, the basic structural parameters of fuel, such as rod diameter of 9.1 mm, have never changed. This paper focuses on computational estimates of basic neutronic parameters of the fuel cycle that involves assemblies consisting of fuel rods with diameter reduced to 8.9 mm.

  1. Completion Report for Well ER-EC-8

    International Nuclear Information System (INIS)

    2004-01-01

    Well ER-EC-8 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of the Nevada Environmental Restoration Project at the Nevada Test Site, Nye County, Nevada. This well was drilled in the summer of 1999 as part of the U.S. Department of Energy's hydrogeologic investigation program in the Western Pahute Mesa - Oasis Valley region just west of the Nevada Test Site. A 44.5-centimeter surface hole was drilled and cased off to a depth of 129.8 meters below the surface. The hole diameter was then decreased to 31.1 centimeters for drilling to a total depth of 609.6 meters. One completion string with three isolated slotted intervals was installed in the well. A preliminary composite, static water level was measured at the depth of 98.4 meters, 24 days after installation of the completion string. Detailed lithologic descriptions with stratigraphic assignments are included in the report. These are based on evaluation of composite drill cuttings collected every 3 meters, and 20 sidewall samples taken at various depths below 157.9 meters, supplemented by geophysical log data and results of detailed chemical and mineralogical studies of rock samples. Drilling began in Tertiary-age tuff of the Thirsty Canyon Group, and penetrated tuffs of the Beatty Wash Formation, tuff of Buttonhook Wash, and the upper portion of the Ammonia Tanks Tuff. The geologic interpretation of data from this well helps define the location of the western margin of the Timber Mountain caldera complex in the southwestern Nevada volcanic field. Geologic and hydrologic data from the well will aid in development of models to predict groundwater flow and contaminant migration within and near the Nevada Test Site

  2. Seismic-induced accelerations detected by two parallel gravity meters in continuous recording with a high sampling rate at Etna volcano

    Directory of Open Access Journals (Sweden)

    P. Stefanelli

    2008-06-01

    Full Text Available We analyse a microgravity data set acquired from two spring LaCoste & Romberg gravity meters operated in parallel at the same site on Etna volcano (Italy for about two months (August – September 2005. The high sampling rate acquisition (2Hz allowed the correlation of short-lasting gravity fluctuations with seismic events. After characterizing the oscillation behavior of the meters, through the study of spectral content and the background noise level of both sequences, we recognized fluctuations in the gravity data, spanning a range of periods from 1 second to about 30 seconds dominated by components with a period of about 15 ÷ 25 seconds, during time intervals encompassing both local seismic events and large worldwide earthquakes. The data analyses demonstrate that observed earthquake-induced gravity fluctuations have some differences due to diverse spectral content of the earthquakes. When local seismic events which present high frequency content excite the meters, the correlation between the two gravity signals is poor (factor < 0.3. Vice versa, when large worldwide earthquakes occur and low frequency seismic waves dominate the ensuing seismic wavefield, the resonance frequencies of the meters are excited and they react according to more common features. In the latter case, the signals from the two instruments are strongly correlated to each other (up to 0.9. In this paper the behaviors of spring gravimeters in the frequency range of the disturbances produced by local and large worldwide earthquakes are presented and discussed.

  3. Smart metering - energy data management at every meter point; Smart Metering - Energiedatenmanagement an jedem Zaehlpunkt

    Energy Technology Data Exchange (ETDEWEB)

    Keller-Giessbach, D.; Kiel, E. [LogicaCMG, Muenchen (Germany)

    2007-09-15

    The demise of monopolistic structures in the German energy market has also led to a change of perspective on metering. New requirements have to be met. Even in mass processing jobs such as meter reading it is no longer sufficient to simply read consumption data off a technically reliable meter or have customers do this themselves in preparation of billing. Currently used meters were not designed with a mind to demand management, environmental protection through energy conservation, changes in consumer behaviour or new service offers. This has been recognised in many European countries since the beginning of the present decade. The traditional task of metering is developing into a more comprehensive energy data management that takes account of the needs of customers, energy suppliers and regulatory requirements.

  4. Evaluation of different disinfectants on the performance of an on-meter dosed amperometric glucose-oxidase-based glucose meter.

    Science.gov (United States)

    Sarmaga, Don; Dubois, Jeffrey A; Lyon, Martha E

    2011-11-01

    Off-meter dosed photometric glucose-oxidase-based glucose meters have been reported to be susceptible to interference by hydrogen-peroxide-based disinfecting agents. The objective of this study was to determine if a single application of hydrogen-peroxide-containing Accel® wipe to disinfect an on-meter dosed amperometric glucose-oxidase-based glucose meter will influence its performance. The performance of five on-meter dosed amperometric glucose-oxidase-based glucose meters was determined before and after disinfecting the devices with a single application of either CaviWipes® (14.3% isopropanol and 0.23% diisobutyl-phenoxy-ethoxyethyl dimethyl benzyl ammonium chloride) or Accel (0.5% hydrogen peroxide) wipes. Replicate glucose measurements were conducted before disinfecting the devices, immediately after disinfecting, and then 1 and 2 min postdisinfecting, with measurements in triplicate. Analysis was sequentially completed for five different meters. Results were analyzed by a two-way analysis of variance (Analyze-it software). No clinical ( .05) in glucose concentration were detected when the on-meter dosed amperometric glucose-oxidase-based glucose meters were disinfected with either CaviWipes or Accel wipes and measured immediately or 1 or 2 min postdisinfecting. No clinically significant difference in glucose concentration was detected between meters (glucose oxidase amperometric-based glucose meters are not analytically susceptible to interference by a single application of hydrogen-peroxide-containing Accel disinfectant wipes. © 2011 Diabetes Technology Society.

  5. Wet gas flow modeling for a vertically mounted Venturi meter

    International Nuclear Information System (INIS)

    Xu, Lijun; Zhou, Wanlu; Li, Xiaomin

    2012-01-01

    Venturi meters are playing an increasingly important role in wet gas metering in natural gas and oil industries. Due to the effect of liquid in a wet gas, the differential pressure over the converging section of a Venturi meter is higher than that when a pure gas flows through with the same flow rate. This phenomenon is referred to as over-reading. Thus, a correction for the over-reading is required. Most of the existing wet gas models are more suitable for higher pressure (>2 MPa) than lower pressure ( 0.5) than lower quality (<0.5) in recent years. However, conditions of lower pressure and lower quality also widely exist in the gas and oil industries. By comparing the performances of eight existing wet gas models in low-pressure range of 0.26–0.86 MPa and low-quality range of 0.07–0.36 with a vertically mounted Venturi meter of diameter ratio 0.45, de Leeuw's model was proven to perform best. Derived from de Leeuw's model, a modified model with better performance for the low-pressure and low-quality ranges was obtained. Experimental data showed that the root mean square of the relative errors of the over-reading was 2.30%. (paper)

  6. Instability of Reference Diameter in the Evaluation of Stenosis After Coronary Angioplasty: Percent Diameter Stenosis Overestimates Dilative Effects Due to Reference Diameter Reduction

    International Nuclear Information System (INIS)

    Hirami, Ryouichi; Iwasaki, Kohichiro; Kusachi, Shozo; Murakami, Takashi; Hina, Kazuyoshi; Matano, Shigeru; Murakami, Masaaki; Kita, Toshimasa; Sakakibara, Noburu; Tsuji, Takao

    2000-01-01

    Purpose: To examine changes in the reference segment luminal diameter after coronary angioplasty.Methods: Sixty-one patients with stable angina pectoris or old myocardial infarction were examined. Coronary angiograms were recorded before coronary angioplasty (pre-angioplasty) and immediately after (post-angioplasty), as well as 3 months after. Artery diameters were measured on cine-film using quantitative coronary angiographic analysis.Results: The diameters of the proximal segment not involved in the balloon inflation and segments in the other artery did not change significantly after angioplasty, but the reference segment diameter significantly decreased (4.7%). More than 10% luminal reduction was observed in seven patients (11%) and more than 5% reduction was observed in 25 patients (41%). More than 5% underestimation of the stenosis was observed in 22 patients (36%) when the post-angioplasty reference diameter was used as the reference diameter, compared with when the pre-angioplasty measurement was used and more than 10% underestimation was observed in five patients (8%).Conclusion: This study indicated that evaluation by percent diameter stenosis, with the reference diameter from immediately after angioplasty, overestimates the dilative effects of coronary angioplasty, and that it is thus better to evaluate the efficacy of angioplasty using the absolute diameter in addition to percent luminal stenosis

  7. 78 FR 24192 - J.P. Morgan Ventures Energy Corp. v. Midwest Independent System Operator, Inc. PJM...

    Science.gov (United States)

    2013-04-24

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL13-58-000] J.P. Morgan Ventures Energy Corp. v. Midwest Independent System Operator, Inc. PJM Interconnection, L.L.C.; Notice of Complaint Take notice that on April 10, 2013, J.P. Morgan Ventures Energy Corporation (JPMVEC or Complainant...

  8. Smart Metering. Technological, economic and legal aspects. 2. ed.; Smart Metering. Technologische, wirtschaftliche und juristische Aspekte des Smart Metering

    Energy Technology Data Exchange (ETDEWEB)

    Koehler-Schute, Christiana (ed.)

    2010-07-01

    Smart metering comprises more than just meter technology, and the use of information and communication technologies is indispensable. Processes, roles and business models must be reconsidered as further challenges arise in the context of smart metering. For one, there is the operator of the metering points. Secondly, there is the end user who is in the role of an active market partner. Further, there is smart metering as a basic technology, e.g. for smart grids and smart homes. In spite of the need for action, many utilities are reluctant to introduce smart metering. Reasons for this are the cost, a lack of defined standards, and an unclear legal situation. On the other hand, smart metering offers potential for grids and distribution that should be made use of. The authors discuss all aspects of the subject. The point out the chances and limitations of smart metering and present their own experience. [German] Smart Metering geht weit ueber die Zaehlertechnologie hinaus und der Einsatz von Informations- und Kommunikationstechnologien ist unabdingbar. Damit einhergehend muessen Prozesse, Rollen und auch Geschaeftsmodelle neu durchdacht werden. Denn weitere Herausforderungen stehen im direkten Zusammenhang mit Smart Metering. Das ist zum einen die Rolle des Messstellenbetreibers / Messdienstleisters. Das ist zum anderen der Endnutzer, dem die Rolle des aktiven Marktpartners zugedacht wird. Das ist des Weiteren das Smart Metering als Basistechnologie beispielsweise fuer Smart Grid und Smart Home. Trotz des Handlungsdrucks stehen viele Unternehmen der Energiewirtschaft dem Smart Metering zurueckhaltend gegenueber. Drei gewichtige Gruende werden ins Feld gefuehrt: die Kostenfrage, nicht definierte Standards und die in vielen Bereichen ungeklaerte Gesetzeslage. Demgegenueber bietet das Smart Metering Potenziale fuer Netz und Vertrieb, die es zu nutzen gilt. Die Autoren setzen sich in ihren Beitraegen mit diesen Themen auseinander, zeigen Chancen, aber auch Grenzen des

  9. Ultrasonic flow-meter test in sodium

    International Nuclear Information System (INIS)

    Ishii, Y.; Uno, O.; Kamei, M.

    1978-01-01

    As a part of the R and D programme for the prototype fast breeder reactor MONJU, an ultrasonic flow-meter (USFM) test is being carried out in sodium in the O-Arai Engineering Center of PNC. Prior to the present test, an in-water test was done at the manufacturer's as a preliminary investigation. The results reported here are the results up to the present. Calibration tests using the actual fluid were conducted on a 12-inch ultrasonic flow-meter with guide rods fabricated for sodium flow measurement. The test conditions in sodium were a temperature of 200 approximately 400 0 C and flow-rates of 0 approximately 6m/s. The main results are: (1) The linearity of output signal was good and accuracy was within 1%; (2) The alternating type of the USFM was much better than the fixed type in temperature change; (3) 2MHz of transducer frequency was better than 3MHz in sodium; (4) The S/N ratio of the ultrasonic signal and the length/diameter effect in a wide range in sodium surpassed the in-water test. (author)

  10. Evaluation of Suppression of Hydroprocessed Renewable Jet (HRJ) Fuel Fires with Aqueous Film Forming Foam (AFFF)

    Science.gov (United States)

    2011-07-01

    Collecting particles from an open pan fire would preclude the consideration of isokinetic sampling usually required in Method 5, but this would...hydroprocessed renewable jet fuel in2 square inches JP-8 jet propellant 8, i.e. jet fuel kW kilowatts m2 square meters Mil-Spec Military Specification min

  11. Evolution, calibration, and operational characteristics of the two-dimensional test section of the Langley 0.3-meter transonic cryogenic tunnel

    Science.gov (United States)

    Ladson, Charles L.; Ray, Edward J.

    1987-01-01

    Presented is a review of the development of the world's first cryogenic pressure tunnel, the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT). Descriptions of the instrumentation, data acquisition systems, and physical features of the two-dimensional 8- by 24-in, (20.32 by 60.96 cm) and advanced 13- by 13-in (33.02 by 33.02 cm) adaptive-wall test-section inserts of the 0.3-m TCT are included. Basic tunnel-empty Mach number distributions, stagnation temperature distributions, and power requirements are included. The Mach number capability of the facility is from about 0.20 to 0.90. Stagnation pressure can be varied from about 80 to 327 K.

  12. 78 FR 16262 - J.P. Morgan Ventures Energy Corporation; Supplemental Notice That Initial Market-Based Rate...

    Science.gov (United States)

    2013-03-14

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER13-830-000] J.P. Morgan... Blanket Section 204 Authorization This is a supplemental notice in the above-referenced proceeding, of J.P...-8659. Dated: March 7, 2013. Nathaniel J. Davis, Sr., Deputy Secretary. [FR Doc. 2013-05859 Filed 3-13...

  13. Microprocessor controlled digital period meter

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1980-01-01

    A microprocessor controlled digital period meter has been developed and tested operationally on a reactor at Argonne National Laboratory. The principle of operation is the mathematical relationship between asymptotic periods and pulse counting circuitry. This relationship is used to calculate and display the reactor periods over a range of /plus or minus/1 second to /plus or minus/999 seconds. The time interval required to update each measurement automatically varies from 8 seconds at the lowest counting rates to 2 seconds at higher counting rates. The paper will describe hardware and software design details and show the advantages of this type of Period Meter over the conventional circuits. 1 ref

  14. Improvement of estimation method of two-phase flow in a large diameter pipe. 2. Development of mechanistic interfacial drag force model

    International Nuclear Information System (INIS)

    Okawa, Tomio; Yoneda, Kimitoshi

    1998-01-01

    It is experimentally clarified that behavior of gas-liquid two-phase flow in large diameter pipe is different from one occurred in small diameter pipe. However, no special model for large diameter pipe is used in existing nuclear reactor safety analysis codes. In the present study, detailed investigation about the two-phase flow model used in the safety analysis was carried out to specify the physical phenomena which should be modeled more precisely. Based on the investigation, steam-water two-phase flow experiments using large diameter pipe was conducted to obtain new models. As a result, new evaluation methods for bubble size, heterogeneous distribution of void fraction, and wake formed behind bubble were developed. These new models were applied to the prediction of steam-water two-phase flow experiments using large diameter pipes to clarify their validity. It was consequently demonstrated that the accuracy of the numerical solution is remarkably improved not only for the experiment used for model development but also for the experiment where the pipe diameter, pressure, velocities, void fraction are different. (author)

  15. MODELING AND DESIGN OF INNOVATIVE SMALL DIAMETER GRAVITY SEWERAGE SYSTEM

    Directory of Open Access Journals (Sweden)

    Tadeusz Nawrot

    2017-05-01

    Full Text Available The article presents modern methods of hydraulic design of an innovative small diameter gravity sewerage system. In this system, domestic wastewater is preliminary treated in septic tanks equipped with outlet filters, thus the effluent features are similar to those of clear water. Innovative non-return valves at the outlets eliminate introduction of air to the system and thus the flows can be treated as one-phase ones. Computer codes EPANET 2 and SWMM 5.0 were applied and compared. Two flow schemes typical for the sewerage system were implemented in EPANET 2, and the third - in a slightly modified SWMM 5.0. Simulation results were validated on empirical data obtained on a laboratory physical model, consisting of four tanks of minimum volumes 600 dm3 each, connecting PE pipelines of diameters 25 mm and 36 mm and relevant sanitary fittings. Water inflows, typical for domestic wastewater outflows from single homesteads, were provided by a pump. Water flows were measured using water meters with pulse outputs, and water levels in tanks by pressure transducers. Hydraulic characteristics of filters and non-return valves were provided. Simulation results showed good agreement with the empirical data. Ranges of values of design parameters, needed for successful application of both codes, were established and discussed.

  16. Aggregatibacter (Actinobacillus actimycetemcomitans leukotoxin and human periodontitis – A historic review with emphasis on JP2

    Directory of Open Access Journals (Sweden)

    Chi-Cheng Tsai

    2018-04-01

    Full Text Available Aggregatibacter (Actinobacillus actimycetemcomitans (Aa is a gram-negative bacterium that colonizes the human oral cavity and is causative agent for localized aggressive (juvenile periodontitis (AgP. In the middle of 1990s, a specific JP2 clone of belonging to the cluster of serotype b strains of Aa with highly leukotoxicity (leukotoxin, LtxA able to kill human immune cells was isolated. JP2 clone of Aa was strongly associated with in particularly in rapidly progressing forms of aggressive periodontitis. The JP2 clone of Aa is transmitted through close contacts. Therefore, AgP patients need intense monitoring of their periodontal status as the risk for developing severely progressing periodontitis lesions are relatively high. Furthermore, timely periodontal treatment, including periodontal surgery supplemented by the use of antibiotics, is warranted. More importantly, periodontal attachment loss should be prevented by early detection of the JP2 clone of Aa by microbial diagnosis testing and/or preventive means. Keywords: Aggregatibacter (Actinobacillus actinomycetemcomitans, Aggressive periodontitis, Leukotoxin (LtxA, Polymorphonuclear leukocytes (PMNs

  17. Balanced Flow Meters without Moving Parts

    Science.gov (United States)

    Kelley, Anthony R.; VanBuskirk, Paul

    2008-01-01

    Balanced flow meters are recent additions to an established class of simple, rugged flow meters that contain no moving parts in contact with flow and are based on measurement of pressure drops across objects placed in flow paths. These flow meters are highly accurate, minimally intrusive, easily manufacturable, and reliable. A balanced flow meter can be easily mounted in a flow path by bolting it between conventional pipe flanges. A balanced flow meter can be used to measure the flow of any of a variety of liquids or gases, provided that it has been properly calibrated. Relative to the standard orifice-plate flow meter, the balanced flow meter introduces less turbulence and two times less permanent pressure loss and is therefore capable of offering 10 times greater accuracy and repeatability with less dissipation of energy. A secondary benefit of the reduction of turbulence is the reduction of vibration and up to 15 times less acoustic noise generation. Both the balanced flow meter and the standard orifice-plate flow meter are basically disks that contain holes and are instrumented with pressure transducers on their upstream and downstream faces. The most obvious difference between them is that the standard orifice plate contains a single, central hole while the balanced flow meter contains multiple holes. The term 'balanced' signifies that in designing the meter, the sizes and locations of the holes are determined in an optimization procedure that involves balancing of numerous factors, including volumetric flow, mass flow, dynamic pressure, kinetic energy, all in an effort to minimize such undesired effects as turbulence, pressure loss, dissipation of kinetic energy, and non-repeatability and nonlinearity of response over the anticipated range of flow conditions. Due to proper balancing of these factors, recent testing demonstrated that the balanced flow-meter performance was similar to a Venturi tube in both accuracy and pressure recovery, but featured reduced

  18. Numerical simulation of two-phase slug flow with liquid carryover in different diameter ratio T-junction

    Science.gov (United States)

    Pao, W.; Hon, L.; Saieed, A.; Ban, S.

    2017-10-01

    A smaller diameter conduit pointing at 12 o’clock position is typically hot-tapped to a horizontal laying production header in offshore platform to tap produced gas for downstream process train. This geometric feature is commonly known as T-junction. The nature of multiphase fluid splitting at the T-junction is a major operational challenge due to unpredictable production environment. Often, excessive liquid carryover occurs in the T-junction, leading to complete platform trip and halt production. This is because the downstream process train is not designed to handle excessive liquid. The objective of this research is to quantify the effect of different diameter ratio on phase separation efficiency in T-junction. The liquid carryover is modelled as two-phase air-water flow using Eulerian Mixture Model coupled with Volume of Fluid Method to mimic the slug flow in the main pipe. The focus in this paper is 0.0254 m (1 inch) diameter horizontal main arm and vertical branch arm with diameter ratio of 1.0, 0.5 and 0.3. The present research narrowed the investigation to only slug flow regime using Baker’s map as reference. The investigation found that, contrary to common believe, smaller diameter ratio T-junction perform worse than larger diameter ratio T-junction.

  19. Uncertainty analysis of power monitoring transit time ultrasonic flow meters

    International Nuclear Information System (INIS)

    Orosz, A.; Miller, D. W.; Christensen, R. N.; Arndt, S.

    2006-01-01

    A general uncertainty analysis is applied to chordal, transit time ultrasonic flow meters that are used in nuclear power plant feedwater loops. This investigation focuses on relationships between the major parameters of the flow measurement. For this study, mass flow rate is divided into three components, profile factor, density, and a form of volumetric flow rate. All system parameters are used to calculate values for these three components. Uncertainty is analyzed using a perturbation method. Sensitivity coefficients for major system parameters are shown, and these coefficients are applicable to a range of ultrasonic flow meters used in similar applications. Also shown is the uncertainty to be expected for density along with its relationship to other system uncertainties. One other conclusion is that pipe diameter sensitivity coefficients may be a function of the calibration technique used. (authors)

  20. Correlation between in vivo and in vitro pulmonary responses to jet propulsion fuel-8 using precision-cut lung slices and a dynamic organ culture system.

    Science.gov (United States)

    Hays, Allison M; Lantz, R Clark; Witten, Mark L

    2003-01-01

    In tissue slice models, interactions between the heterogeneous cell types comprising the lung parenchyma are maintained thus providing a controlled system for the study of pulmonary toxicology in vitro. However, validation of the model in vitro system must be affirmed. Previous reports, in in vivo systems, have demonstrated that Clara cells and alveolar type II cells are the targets following inhalation of JP-8 jet fuel. We have utilized the lung slice model to determine if cellular targets are similar following in vitro exposure to JP-8. Agar-filled adult rat lung explants were cored and precision cut, using the Brende/Vitron tissue slicer. Slices were cultured on titanium screens located as half-cylinders in cylindrical Teflon cradles that were loaded into standard scintillation vials and incubated at 37 degrees C. Slices were exposed to JP-8 jet fuel (0.5 mg/ml, 1.0 mg/ml, and 1.5 mg/ml in medium) for up to 24 hours. We determined ATP content using a luciferin-luciferase bioluminescent assay. No significant difference was found between the JP-8 jet fuel doses or time points, when compared to controls. Results were correlated with structural alterations following aerosol inhalation of JP-8. As a general observation, ultrastructural evaluation of alveolar type cells revealed an apparent increase in the number and size of surfactant secreting lamellar bodies that was JP-8 jet fuel-dose dependent. These results are similar to those observed following aerosol inhalation exposure. Thus, the lung tissue slice model appears to mimic in vivo effects of JP-8 and therefore is a useful model system for studying the mechanisms of lunginjury following JP-8 exposure.

  1. Development of quick-response area-averaged void fraction meter

    International Nuclear Information System (INIS)

    Watanabe, Hironori; Iguchi, Tadashi; Kimura, Mamoru; Anoda, Yoshinari

    2000-11-01

    Authors are performing experiments to investigate BWR thermal-hydraulic instability under coupling of neutronics and thermal-hydraulics. To perform the experiment, it is necessary to measure instantaneously area-averaged void fraction in rod bundle under high temperature/high pressure gas-liquid two-phase flow condition. Since there were no void fraction meters suitable for these requirements, we newly developed a practical void fraction meter. The principle of the meter is based on the electrical conductance changing with void fraction in gas-liquid two-phase flow. In this meter, metal flow channel wall is used as one electrode and a L-shaped line electrode installed at the center of flow channel is used as the other electrode. This electrode arrangement makes possible instantaneous measurement of area-averaged void fraction even under the metal flow channel. We performed experiments with air/water two-phase flow to clarify the void fraction meter performance. Experimental results indicated that void fraction was approximated by α=1-I/I o , where α and I are void fraction and current (I o is current at α=0). This relation holds in the wide range of void fraction of 0∼70%. The difference between α and 1-I/I o was approximately 10% at maximum. The major reasons of the difference are a void distribution over measurement area and an electrical insulation of the center electrode by bubbles. The principle and structure of this void fraction meter are very basic and simple. Therefore, the meter can be applied to various fields on gas-liquid two-phase flow studies. (author)

  2. Calibration of ionization chamber and GM counter survey meters, (1)

    International Nuclear Information System (INIS)

    Bingo, Kazuyoshi; Kajimoto, Yoichi; Suga, Shin-ichi

    1978-01-01

    Three types of ionization chamber survey meters and a type of GM counter survey meter were calibrated for measuring the β-ray absorbed dose rate in a working area. To estimate the β-ray absorbed dose rate, a survey meter was used without and with a filter. A reading of survey meter's indicator measured with the filter was subtracted from a reading measured without the filter, and then the absorbed dose rate was obtained by multiplying this remainder by a conversion coefficient. The conversion coefficients were roughly constant with distance more than 8 cm (ionization chamber survey meters) and with distance more than 5 cm (GM counter survey meter). The conversion coefficient was dependent on β-ray energies. In order to measure the absorbed dose rate of tissue whose epidermal thickness is 40 mg/cm 2 , the constant value, 4 (mrad/h)/(mR/h), was chosen independently of β-ray energies as the conversion coefficient of three types of ionization chamber survey meters. The conversion coefficient of the GM counter survey meter was more energy dependent than that of every type of ionization chamber survey meter. (author)

  3. Nuclear Enterprises portable dose rate meter type PDR4 and external probes types BP1/1, BP8 and GP9

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-08-01

    The performance characteristics of Nuclear Enterprises Portable Dose Rate Meter Type PDR4 are evaluated under the headings: general description, facilities and controls, radiation characteristics, electrical characteristics, environmental characteristics, mechanical characteristics, the manual, summary of performance, and conclusions. Results of an investigation of the radiation characteristics of the external probes Type BP1/1, Type BP8, and Type GP9 are also detailed. (U.K.)

  4. Diameter structure modeling and the calculation of plantation volume of black poplar clones

    Directory of Open Access Journals (Sweden)

    Andrašev Siniša

    2004-01-01

    Full Text Available A method of diameter structure modeling was applied in the calculation of plantation (stand volume of two black poplar clones in the section Aigeiros (Duby: 618 (Lux and S1-8. Diameter structure modeling by Weibull function makes it possible to calculate the plantation volume by volume line. Based on the comparison of the proposed method with the existing methods, the obtained error of plantation volume was less than 2%. Diameter structure modeling and the calculation of plantation volume by diameter structure model, by the regularity of diameter distribution, enables a better analysis of the production level and assortment structure and it can be used in the construction of yield and increment tables.

  5. Orifice Mass Flow Calculation in NASA's W-8 Single Stage Axial Compressor Facility

    Science.gov (United States)

    Bozak, Richard F.

    2018-01-01

    Updates to the orifice mass flow calculation for the W-8 Single Stage Axial Compressor Facility at NASA Glenn Research Center are provided to include the effect of humidity and incorporate ISO 5167. A methodology for including the effect of humidity into the inlet orifice mass flow calculation is provided. Orifice mass flow calculations provided by ASME PTC-19.5-2004, ASME MFC-3M-2004, ASME Fluid Meters, and ISO 5167 are compared for W-8's atmospheric inlet orifice plate. Differences in expansion factor and discharge coefficient given by these standards give a variation of about +/- 75% mass flow except for a few cases. A comparison of the calculations with an inlet static pressure mass flow correlation and a fan exit mass flow integration using test data from a 2017 turbofan rotor test in W-8 show good agreement between the inlet static pressure mass flow correlation, ISO 5167, and ASME Fluid Meters. While W-8's atmospheric inlet orifice plate violates the pipe diameter limit defined by each of the standards, the ISO 5167 is chosen to be the primary orifice mass flow calculation to use in the W-8 facility.

  6. Flow-Signature Analysis of Water Consumption in Nonresidential Building Water Networks Using High-Resolution and Medium-Resolution Smart Meter Data: Two Case Studies

    Science.gov (United States)

    Clifford, Eoghan; Mulligan, Sean; Comer, Joanne; Hannon, Louise

    2018-01-01

    Real-time monitoring of water consumption activities can be an effective mechanism to achieve efficient water network management. This approach, largely enabled by the advent of smart metering technologies, is gradually being practiced in domestic and industrial contexts. In particular, identifying water consumption habits from flow-signatures, i.e., the specific end-usage patterns, is being investigated as a means for conservation in both the residential and nonresidential context. However, the quality of meter data is bivariate (dependent on number of meters and data temporal resolution) and as a result, planning a smart metering scheme is relatively difficult with no generic design approach available. In this study, a comprehensive medium-resolution to high-resolution smart metering program was implemented at two nonresidential trial sites to evaluate the effect of spatial and temporal data aggregation. It was found that medium-resolution water meter data were capable of exposing regular, continuous, peak use, and diurnal patterns which reflect group wide end-usage characteristics. The high-resolution meter data permitted flow-signature at a personal end-use level. Through this unique opportunity to observe water usage characteristics via flow-signature patterns, newly defined hydraulic-based design coefficients determined from Poisson rectangular pulse were developed to intuitively aid in the process of pattern discovery with implications for automated activity recognition applications. A smart meter classification and siting index was introduced which categorizes meter resolution in terms of their suitable application.

  7. Smart Metering. Between technical challenge and societal acceptance - Interdisciplinary status quo; Smart Metering. Zwischen technischer Herausforderung und gesellschaftlicher Akzeptanz - Interdisziplinaerer Status Quo

    Energy Technology Data Exchange (ETDEWEB)

    Westermann, Dirk; Doering, Nicola; Bretschneider, Peter (eds.)

    2013-04-01

    The international research project RESIDENS (more efficient energy utilization by means of system technical integration of the private ultimate consumer) investigates the technology of smart metering that is the utilization of intelligent smart meters in private households. The interdisciplinary character of the RESIDENS project becomes visible by different sub-projects examining different formulations of a question from perspectives of different scientific disciplines: First of all, chapter 2 of the contribution under consideration follows up the question, what impact the media coverage on smart metering has on the perception of this technology in the population at large. Chapter 3 reports on the state of the art of the smart metering. Chapter 4 illustrates how a load control of private consumers can be performed by means of the smart meter technology. Chapter 5 reports on the impacts of the smart metering on the procurement of energy in the liberalised energy market. Chapter 6 investigates the smart metering from the customer's point of view. Concretely, the user-friendliness of an internet portal is evaluated by which the customers may follow up their consumption of electricity by means of an intelligent smart meter continuously. Chapter 7 illustrates legal aspects of smart metering from the perspective of the customer, electricity suppliers and distribution system operators. Chapter 8 presents the conception and implementation of an online gaming operation for the promotion of competency of private power customers: In line with this game, the participants may learn to handle smart metering and flexible electricity tariffs in an entertaining manner. Finally, chapter 9 reports on an expert interview in which the smart metering technology is evaluated by public utilities being involved in this project.

  8. Concordance and discordance between two measures of lower extremity function: 400 meter self-paced walk and SPPB.

    Science.gov (United States)

    Sayers, Stephen P; Guralnik, Jack M; Newman, Anne B; Brach, Jennifer S; Fielding, Roger A

    2006-04-01

    The purpose of the study was to assess the concurrent validity of the 400 meter self-paced walk test (400-m W) against the commonly used short physical performance battery (SPPB). A secondary purpose was to determine whether the 400-m W could better discriminate physical performance among high functioning older adults by examining the distribution of 400-m W scores. 101 men and women (80.8+/-0.4 years) were recruited to participate in the study. The 400-mW and SPPB assessed lower extremity function. Lower extremity muscle strength, power, and contraction velocity was assessed using bilateral leg press (LP). Health history was obtained with questionnaire. 400-m W demonstrated moderate correlations with SPPB (Pearson r=0.74; p400-m W performance time (n=20) had more medical conditions (2.8+/-0.4 vs 1.7+/-0.3; p=0.038), more reported falls (0.80+/-0.2 vs 0.19+/-0.1; p=0.016), more medications (3.7+/-0.4 vs 1.8+/-0.4; p=0.001), had lower LP power at 70% of the one repetition maximum (1RM) (336+/-45 W vs 663+/-78 W; p=0.001) and 40% 1RM (329+/-43 W vs 580+/-75 W; p=0.005), and had slower LP contraction velocity at 40% 1RM (77+/-5.5 m/s vs 112+/-8.4 m/s; p=0.001) compared with those below the median (n=16). A substantial number of apparently well functioning older adults demonstrated some limitations in the ability to walk 400 meters. Use of the 400-m W may be justified to obtain information to better discriminate among high functioning elderly.

  9. Visualization of boiling two-phase flow in a small diameter tube using neutron radiography

    International Nuclear Information System (INIS)

    Hibiki, Takashi; Mishima, Kaichiro; Yoneda, Kenji; Fujine, Shigenori; Kanda, Keiji; Nishihara, Hideaki

    1991-01-01

    The characteristics of boiling two-phase flow in a small diameter tube are very important for cooling the blanket in a nuclear fusion reactor or a high performance electronic device. For all these subjects, it is necessary to visualize the flow in a tube as a starting point of the study. However, when an optical method cannot be used for the visualization, it is expected that neutron radiography is useful. In this study, the feasibility of visualization of boiling two-phase flow in a small diameter tube was investigated by using various facilities of neutron radiography as the first step. The basic concept of neutron radiography and the block diagram of a neutron television system are shown. The neutron beam attenuated by water in the test section makes a scintillator emit visible light, and produces an image of two-phase flow, which is taken with a TV camera. Thus the image can be observed at real time. Three kinds of the experiments were performed with the facilities of KUR, NSRR and JRR-3. The experimental methods and the results are reported. The images obtained were sufficiently clear. (K.I.)

  10. 77 FR 40586 - Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter...

    Science.gov (United States)

    2012-07-10

    ...-01] Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter... Technology (NIST) seeks comments on Draft NISTIR 7823, Advanced Metering Infrastructure Smart Meter... conformance test requirements for the firmware upgradeability process for the Advanced Metering Infrastructure...

  11. Investigation and Comparison of Separate Meter-In Separate Meter-Out Control Strategies

    DEFF Research Database (Denmark)

    Pedersen, Henrik C.; Andersen, Torben Ole; Skoubo, Tobias

    2014-01-01

    In the later years, there has been an increased focus on new valve types, which yield the possibility to do Separate Meter-In Separate Meter-Out (SMISMO) control. This includes both digital valves, but proportional valves with separate metering spools and build in pressure sensors are also emerging....... The possibility to independently control the meter-in and meter-out side not only increase the functionality of the system, but also opens up for better performance and/or lowered energy consumption. The focus of the current paper is therefore on investigation and comparison of what may be obtained using...

  12. Beyond revenue metering -- a new age for automatic meter reading

    Energy Technology Data Exchange (ETDEWEB)

    Chebra, R. J. [RJC Consulting L.L.C., PQ (Canada)

    2002-10-01

    Advanced metering, data management, and communications possibilities of automated meter reading are explored. Applications in the area of demand side management, including load reduction, peak shaving and load shifting, new tariff structures based on the 'time of use incentive/penalty' approach, and information grade metering are emphasized. Based on trends and expectations, it is predicted that AMR will continue to experience rapid growth and deployment as new services are made available to the mass market. For example, technological advances will enable the industry to make 'time of use metering ' more attractive and beneficial to residential consumers, and embedded intelligence will make it possible to achieve more holistic energy environments.

  13. Density and water content measurement with two dual detector probes

    International Nuclear Information System (INIS)

    Cariou, J.; Menard, J.

    1980-01-01

    The ''Laboratoires des Ponts et Chaussees'' have developed an electronic device for geological prospections. This system includes gamma-gamma and neutron-neutron probes for continuous measurement in borehole down to one hundred meters. It is used, as well to measure the density and the water content in the field of soil mechanic engineering. When the diameter is not constant all along the borehole the two probes have to use a dual detector procedure. When constant, a simple detector procedure is sufficient to obtain density and water content. Two examples show the possibilities of this apparatus, particularly to control the borehole diameter and the soil chemical composition [fr

  14. Manufacturing of 5.5 Meter Diameter Cryogenic Fuel Tank Domes for the NASA Ares I Rocket

    Science.gov (United States)

    Jones, Ronald E.; Carter, Robert W.

    2012-01-01

    The Ares I rocket is the first launch vehicle scheduled for manufacture under the National Aeronautic and Space Administration s (NASA s) Constellation program. A series of full-scale Ares I development articles have been constructed on the Robotic Weld Tool at the NASA George C. Marshall Space Flight Center in Huntsville, Alabama. The Robotic Weld Tool is a 100 ton, 7-axis, robotic manufacturing system capable of machining and friction stir welding large-scale space hardware. This presentation will focus on the friction stir welding of 5.5m diameter cryogenic fuel tank components; specifically, the liquid hydrogen forward dome (LH2 MDA) and the common bulkhead manufacturing development articles (CBMDA). The LH2 MDA was the first full-scale, flight-like Ares I hardware produced under the Constellation Program. It is a 5.5m diameter elliptical dome assembly consisting of eight gore panels, a y-ring stiffener and a manhole fitting. All components are made from aluminum-lithium alloy 2195. Conventional and self-reacting friction stir welding was used on this article. Manufacturing solutions will be discussed including the implementation of photogrammetry, an advanced metrology technique, as well as fixtureless welding. The LH2 MDA is the first known fully friction stir welded dome ever produced. The completion of four Common Bulkhead Manufacturing Development Articles (CBMDA) will also be highlighted. Each CBMDA consists of a 5.5m diameter spun-formed dome friction stir welded to a y-ring stiffener. The domes and y-rings are made of aluminum 2014 and 2219 respectively. An overview of CBMDA manufacturing processes and the effect of tooling on weld defect formation will be discussed.

  15. Corrosion and deposit determination in large diameter pipes by radiography

    International Nuclear Information System (INIS)

    Harara, W.

    2006-08-01

    Two steel reference pipes with outer diameters of 8 and 12 inches were machined to make artificial defects on each of them, such as inside and outside steps of different wall thicknesses, inside and outside flat bottomed holes (FBH) of different diameters and depths on steps, flat area (FA), and ground patch (GP). The artificial defect were made to simulate natural corrosion attack as regular corrosion and pitting. The two reference pipes were tested according to tangential radiography technique and double wall single image technique. Tangential radiography technique had been applied using Co-60 radio-isotope to determine the steps thicknesses, the FBH, the remaining wall thickness under the FA, the remaining wall thickness above the GP, and the minimum detectable thickness of the artificial cement deposit on the two reference pipes, with and without insulation. Double wall single image technique had also been applied on the two reference pipes with and without insulation using Ir-192 radio-isotope to measure the flat bottomed holes depths, GP depth, and FA depth by density measurement. The measurement results obtained from the radiographs confirm that, tangential radiography technique can be applied to detect and evaluate the inside and outside regular corrosion attack in the large diameter pipes. It can also be applied to detect and evaluate the outside FBH with depth equal or greater than 10%. Inside 10% FBH and inside 20% FBH can not be detected if their diameters are not larger than certain value related to diameter and wall thickness of the pipe under test. Increasing the film density up to 5 outside the pipe did not provide any detection improvement of 10% and 20% inside FBH. Tangential radiography technique can also be applied to detect and measure the deposit inside the pipes. Double wall technique can be applied as an alternative method of the tangential radiography technique to detect and to evaluate the shallow and small diameter, 10% and 20% inside FBH

  16. Radiofrequency energy exposure from the Trilliant smart meter.

    Science.gov (United States)

    Foster, Kenneth R; Tell, Richard A

    2013-08-01

    This paper reviews radiofrequency (RF) field levels produced by electric utility meters equipped with RF transceivers (so-called Smart Meters), focusing on meters from one manufacturer (Trilliant, Redwood City, CA, USA, and Granby, QC, Canada). The RF transmission levels are summarized based on publicly available data submitted to the U.S. Federal Communications Commission supplemented by limited independent measurements. As with other Smart Meters, this meter incorporates a low powered radiofrequency transceiver used for a neighborhood mesh network, in the present case using ZigBee-compliant physical and medium access layers, operating in the 2.45 GHz unlicensed band but with a proprietary network architecture. Simple calculations based on a free space propagation model indicate that peak RF field intensities are in the range of 10 mW m or less at a distance of more than 1-2 m from the meters. However, the duty cycle of transmission from the meters is very low (meter that were consistent with data reported by the vendor to the U.S. Federal Communications Commission. Limited measurements conducted in two houses with the meters were unable to clearly distinguish emissions from the meters from the considerable electromagnetic clutter in the same frequency range from other sources, including Wi-Fi routers and, when it was activated, a microwave oven. These preliminary measurements disclosed the difficulties that would be encountered in characterizing the RF exposures from these meters in homes in the face of background signals from other household devices in the same frequency range. An appendix provides an introduction to Smart Meter technology. The RF transmitters in wireless-equipped Smart Meters operate at similar power levels and in similar frequency ranges as many other digital communications devices in common use, and their exposure levels are very far below U.S. and international exposure limits.

  17. Assessment of the implementation regulations for smart meters; Beoordeling uitvoeringsregelingen Slimme Meter

    Energy Technology Data Exchange (ETDEWEB)

    Boekema, J.

    2011-03-15

    TNO (Netherlands) assessed whether the smart meter is reliable and future proof. By request of the Dutch Ministry of Economic Affairs, Agriculture and Innovation (ELI) an assessment was conducted of the requirements for smart meters and, as formulated in the Order in Council 'Decree on remotely readable metering devices', based on 48 tests regarding security, privacy and future stability. Taking into account a number of described recommendations, TNO deems the legislation and implementation schemes sufficient to allow for safe, reliable and future proof implementation of smart meters in the Netherlands. [Dutch] TNO heeft beoordeeld of de slimme meter betrouwbaar en toekomstvast is. Ten behoeve van het ministerie van Economische Zaken, Landbouw en Innovatie (ELI) zijn de eisen die aan slimme meters worden gesteld, en zoals verwoord in de AmvB 'Besluit op afstand uitleesbare meetinrichtingen', beoordeeld aan de hand van 48 toetsen over zekerheid (security), persoonlijke levenssfeer (privacy) en toekomstvastheid. Met inachtneming van een aantal omschreven aanbevelingen, vindt TNO wetgeving en uitvoeringsregelingen zodanig dat daarmee een veilige, betrouwbare en toekomstvaste slimme meter geimplementeerd kan worden in Nederland.

  18. Portable digital reactivity meter for power reactors

    Energy Technology Data Exchange (ETDEWEB)

    Steffen, G [Nuklear-Ingenieur Service G.m.b.H., Hanau (Germany, F.R.)

    1977-07-01

    A digital reactivity meter has been developed, which can be used for all kinds of kinetic reactivity measurements in PWR's and BWR's. The input signals may be supplied by standard neutron detectors of the reactor. The hardware configuration consists of a minicomputer with ADC and DAC, a 'Silent' terminal and a high speed paper tape reader/punch. It is easily transportable. The reactivity meter solves the inverse kinetics equations for 6 delayed neutron groups, simultaneously for up to 8 logarithmic or linear neutron flux signals. It has been successfully tested at Biblis A PWR and the KRB BWR.

  19. Portable wireless metering

    Energy Technology Data Exchange (ETDEWEB)

    DiPaola, L [Powtel Monitoring Systems, Inc., Ajax, ON (Canada)

    1996-12-31

    Portable meters were discussed as alternatives to standard billing meters for temporary installations. Current, voltage and power factor at a distribution station were measured to calculate kW and kVAR, using an easy to install product that communicates live readings directly to the existing billing system. A background of situations where temporary metering is a possible alternative to regular meters was presented. Use of electronic, clamp on Electronic Recording Ammeters (ERA) and their drawbacks were discussed. An improved temporary metering solution using FM radio transmission to deliver live data to a receiving device, the Eagle Series 3500, was introduced. Improvements over previous ERA systems were discussed, including accuracy, lack of batteries, immediate confirmation of functionality, current, voltage and power factor monitoring, direct feed to billing system, line crew savings, need for only a single unit at any given site, bi-directional power flow metering, independent report storage media, and a portable voltage and P.F. diagnostic tool. Details of trial applications at the Utopia distribution station west of Barrie, ON were presented. This technology was said to be still in the testing stage, but its flexibility and economy were sonsidered to be very promising for future application.

  20. Effects of varying hydraulics on the calibration of eight path chordal ultrasonic meters

    International Nuclear Information System (INIS)

    Hauser, E.; Estrada, H.; Regan, J.

    2003-01-01

    Eight path transit time ultrasonic meters are being used in the US, Europe and Japan to support measurement uncertainty power uprates of nuclear power plants. Power uprates rely on the demonstration of improved power accuracy to justify a reduction in the traditional 2% margin between operating power and the power at which loss of coolant accidents and other transients have been analyzed. The flow, density and enthalpy of the feedwater are key elements in the power calculation, and the eight path ultrasonic meters measure the flow and temperature from which these elements are derived. A key element in the uncertainty analysis for these meters is an allowance for the uncertainties that the feedwater flow profiles introduce in the meters' flow calibrations. To minimize and bound this uncertainty calibration tests are performed on each eight path element to be used in an uprate application. This paper describes extensive testing of a prototype eight path meter, results of which have be used to define the sensitivity of 8 path meters to broad variations in flow profiles, both axial and transverse and to establish a methodology whereby the impact of these changes on the uncertainty of the meters can be minimized. This testing confirms the general insensitivity of 8 path chordal systems to axial and transverse fluid velocity profiles. An 8 path chordal system provides a quantitative measurement of the flatness of the axial profile, which allows a quantitative assessment of the differences in hydraulic profile seen by a meter in a plant versus the hydraulic profile seen by that same meter in the calibration lab. Since the sensitivity of the meter's calibration can be established as a function of profile flatness in the lab through parametric testing, the profile flatness in the plant can be used to confirm or to adapt as necessary the calibration coefficient measured in the lab for use in the plant. (author)

  1. O modelo ISA/JP - indicador de performance para diagnóstico do saneamento ambiental urbano ISA/JP model - indicator of performance for the diagnosis of urban environmental health

    Directory of Open Access Journals (Sweden)

    Marie Eugénie Malzac Batista

    2006-03-01

    Full Text Available Neste artigo apresenta-se o modelo ISA/JP - Indicador de Salubridade Ambiental, para análise intra-urbana por setor censitário e bairro como uma contribuição para a gestão urbana com enfoque para a área de saneamento ambiental. Trata-se de uma adaptação do ISA desenvolvido pelo Conselho Estadual de Saneamento do Estado de São Paulo, em 1999. Foi incorporado ao modelo ISA mais um sub-indicador, o de drenagem urbana. A utilização do modelo ISA/JP em um Sistema de Informação Geográfica - SIG permitiu que fosse explorada a potencialidade da espacialização dos resultados. Possibilitou ainda a representação e modelagem do conhecimento, constituindo um Sistema de Apoio a Decisão Espacial - SADE. É apresentado um estudo de caso nos bairros costeiros da cidade de João Pessoa, Brasil. Foi demonstrada a viabilidade do modelo proposto bem como o avanço na descrição da salubridade ambiental, mostrando a variabilidade das informações relevantes no espaço urbano.This work deals with the ISA/JP model - Indicator of Environmental Health for intra-urban analysis, according to the census sector and suburb, as a contribution to the urban management, with a focus on the area of environmental sanitation. It is an adaptation of ISA developed by São Paulo's State Council of Sanitation, in 1999. One more sub-indicator, that of urban drainage, was incorporated to the ISA model. The use of ISA/JP in a System of Geographic Information - SIG - permitted the exploration of the potentiality of distributing the results in the urban area. It also made possible the representation and modeling of knowledge, thus making up a System of Support to Space Decision - SSSD. A case study in the coastal suburbs of João Pessoa City, Brazil, was presented. The viability of the proposed model as well as the advance in the description of environmental health were demonstrated, thus showing the variability of relevant information in the urban space.

  2. Effects of the leakage magnetic field from an analog meter on the response of scintillation survey meters

    International Nuclear Information System (INIS)

    Abe, Toshiaki; Yamamoto, Hisao; Norimura, Toshiyuki; Katase, Akira

    2003-01-01

    Effects of the weak leakage magnetic field are studied on the response of two kinds of scintillation survey meters: an ordinary type for γ-rays and that optimized for the detection of low-energy photons from 125 I. In the presence of the magnetic field, the response of the optimized survey meter decreases to the photons from 125 I, and increases considerably to the background radiations. On the other hand, the response of the ordinary survey meter decreases slightly to both the γ-rays from 131 I and the background radiations. From analysis of the pulse-height spectra for the radiations, such variations of the response are ascribed to the reduction of the amplification factor of photomultiplier tubes by the magnetic field. (author)

  3. Smart metering. Conformance tests for electricity meters; Smart Metering. Konformitaetstests an Stromzaehlern

    Energy Technology Data Exchange (ETDEWEB)

    Bormann, Matthias; Pongratz, Siegfried [VDE Pruef- und Zertifizierungsinstitut, Offenbach (Germany)

    2012-07-01

    Introduction of communication technologies into today's energy network enables the interworking between the domains of smart metering, smart grid, smart home and e-mobility as well as the creation and provisioning of new innovative services such as efficient load adjustment. Due to this convergence the new energy networks are becoming increasingly complex. Ensuring the interworking between all network elements (e.g. electricity meters, gateways) in these smart energy networks is of utmost importance. To this end conformance and interoperability tests have to be defined to ensure that services work as expected. (orig.)

  4. Measurement and modeling of two-phase flow parameters in scaled 8 Multiplication-Sign 8 BWR rod bundle

    Energy Technology Data Exchange (ETDEWEB)

    Yang, X.; Schlegel, J.P.; Liu, Y.; Paranjape, S.; Hibiki, T. [School of Nuclear Engineering, Purdue University, 400 Central Dr., West Lafayette, IN 47907-2017 (United States); Ishii, M., E-mail: ishii@purdue.edu [School of Nuclear Engineering, Purdue University, 400 Central Dr., West Lafayette, IN 47907-2017 (United States)

    2012-04-15

    Highlights: Black-Right-Pointing-Pointer Grid spacers have a significant but not well understood effect on flow behavior and development. Black-Right-Pointing-Pointer Two different length scales are present in rod bundles, which must be accounted for in modeling. Black-Right-Pointing-Pointer An easy-to-implement empirical model has been developed for the two-phase friction multiplier. - Abstract: The behavior of reactor systems is predicted using advanced computational codes in order to determine the safety characteristics of the system during various accidents and to determine the performance characteristics of the reactor. These codes generally utilize the two-fluid model for predictions of two-phase flows, as this model is the most accurate and detailed model which is currently practical for predicting large-scale systems. One of the weaknesses of this approach however is the need to develop constitutive models for various quantities. Of specific interest are the models used in the prediction of void fraction and pressure drop across the rod bundle due to their importance in new Natural Circulation Boiling Water Reactor (NCBWR) designs, where these quantities determine the coolant flow rate through the core. To verify the performance of these models and expand the existing experimental database, data has been collected in an 8 Multiplication-Sign 8 rod bundle which is carefully scaled from actual BWR geometry and includes grid spacers to maintain rod spacing. While these spacer grids are 'generic', their inclusion does provide valuable data for analysis of the effect of grid spacers on the flow. In addition to pressure drop measurements the area-averaged void fraction has been measured by impedance void meters and local conductivity probes have been used to measure the local void fraction and interfacial area concentration in the bundle subchannels. Experimental conditions covered a wide range of flow rates and void fractions up to 80%.

  5. New consumer services provided by smart metering

    Directory of Open Access Journals (Sweden)

    Daminov Ildar

    2015-01-01

    Full Text Available This paper focuses on the issues of smart metering market and considers different services provided by smart metering from consumer point of view. Firstly, smart metering deployment challenges emerging and conventional tariffs, which modify a consumer behavior and thus, the entire electric energy market can be optimized since the customer is motivated to consume less energy. Secondly, the authors illustrate changes in electricity quality, which have an impact on consumer relations with utility. Additionally, two main indices of grid resilience – SAIDI and SAIFI – are exemplified to reveal the improvement potential of smart metering implementation in certain regions of Russia that also influence the consumer. Finally, in-home display and privacy problem directly reflect the consumer’s behavior, thus the private life rights should not be violated as they are guaranteed by law.

  6. Technique of Hurdle Clearing in 400 Meters Hurdles

    OpenAIRE

    Jakoubek, Jiří

    2018-01-01

    Title: Technique of Hurdle Clearing in 400 Meters Hurdles Authors: Jiří Jakoubek Supervisor: PhDr. Aleš Kaplan, Ph.D. Aims: The aim of this thesis is to describe technique of hurdle clearing in 400 meters hurdle race using study review and to examine this technique at particular athlete during training and racing sessions in 400 meters hurdles race. Methods: Technique was compared and examined at young athlete. Two kinograms were used for analysis, one from training and one from racing sessio...

  7. The British Gas Quantum Metering System for pre-payment customers

    International Nuclear Information System (INIS)

    Williams, P.; Fitzpatrick, B.

    1992-01-01

    The development work leading up to the design of the Quantum Metering System is outlined. The main features of the meter including the reusable tokens, metering equipment, credit charging equipment, central controlling equipment and a portable token reader for field use are described in detail, and the two way communication of information is highlighted. (UK)

  8. Measurement of local two-phase flow parameters of nanofluids using conductivity double-sensor probe.

    Science.gov (United States)

    Park, Yu Sun; Chang, Soon Heung

    2011-04-04

    A two-phase flow experiment using air and water-based γ-Al2O3 nanofluid was conducted to observe the basic hydraulic phenomenon of nanofluids. The local two-phase flow parameters were measured with a conductivity double-sensor two-phase void meter. The void fraction, interfacial velocity, interfacial area concentration, and mean bubble diameter were evaluated, and all of those results using the nanofluid were compared with the corresponding results for pure water. The void fraction distribution was flattened in the nanofluid case more than it was in the pure water case. The higher interfacial area concentration resulted in a smaller mean bubble diameter in the case of the nanofluid. This was the first attempt to measure the local two-phase flow parameters of nanofluids using a conductivity double-sensor two-phase void meter. Throughout this experimental study, the differences in the internal two-phase flow structure of the nanofluid were identified. In addition, the heat transfer enhancement of the nanofluid can be resulted from the increase of the interfacial area concentration which means the available area of the heat and mass transfer.

  9. Micro-gen metering solutions

    Energy Technology Data Exchange (ETDEWEB)

    Elland, J.; Dickson, J.; Cranfield, P.

    2003-07-01

    This report summarises the results of a project to investigate the regulation of domestic electricity metering work and identify the most economic options for micro-generator installers to undertake work on electricity meters. A micro-generation unit is defined as an energy conversion system converting non-electrical energy into electrical energy and can include technologies such as photovoltaic systems, small-scale wind turbines, micro-hydroelectric systems, and combined heat and power systems. Details of six tasks are given and cover examination of the existing framework and legal documentation for metering work, the existing technical requirements for meter operators, meter operator personnel accreditation, appraisal of options for meter changes and for micro-generation installation, document change procedures, industry consultation, and a review of the costs implications of the options.

  10. Investigation of ball bond integrity for 0.8 mil (20 microns) diameter gold bonding wire on low k die in wire bonding technology

    Science.gov (United States)

    Kudtarkar, Santosh Anil

    Microelectronics technology has been undergoing continuous scaling to accommodate customer driven demand for smaller, faster and cheaper products. This demand has been satisfied by using novel materials, design techniques and processes. This results in challenges for the chip connection technology and also the package technology. The focus of this research endeavor was restricted to wire bond interconnect technology using gold bonding wires. Wire bond technology is often regarded as a simple first level interconnection technique. In reality, however, this is a complex process that requires a thorough understanding of the interactions between the design, material and process variables, and their impact on the reliability of the bond formed during this process. This research endeavor primarily focused on low diameter, 0.8 mil thick (20 mum) diameter gold bonding wire. Within the scope of this research, the integrity of the ball bond formed by 1.0 mil (25 mum) and 0.8 mil (20 mum) diameter wires was compared. This was followed by the evaluation of bonds formed on bond pads having doped SiO2 (low k) as underlying structures. In addition, the effect of varying the percentage of the wire dopant, palladium and bonding process parameters (bonding force, bond time, ultrasonic energy) for 0.8 mil (20 mum) bonding wire was also evaluated. Finally, a degradation empirical model was developed to understand the decrease in the wire strength. This research effort helped to develop a fundamental understanding of the various factors affecting the reliability of a ball bond from a design (low diameter bonding wire), material (low k and bonding wire dopants), and process (wire bonding process parameters) perspective for a first level interconnection technique, namely wire bonding. The significance of this research endeavor was the systematic investigation of the ball bonds formed using 0.8 mil (20 microm) gold bonding wire within the wire bonding arena. This research addressed low k

  11. Cryogenic Thermal Absorptance Measurements on Small-Diameter Stainless Steel Tubing

    Science.gov (United States)

    Tuttle, James; Jahromi, Amir; Canavan, Edgar; DiPirro, Michael

    2015-01-01

    The Mid Infrared Instrument (MIRI) on the James Webb Space Telescope includes a mechanical cryocooler which cools its detectors to their 6 Kelvin operating temperature. The coolant gas flows through several meters of small-diameter stainless steel tubing, which is exposed to thermal radiation from its environment. Over much of its length this tubing is gold-plated to minimize the absorption of this radiant heat. In order to confirm that the cryocooler will meet MIRI's requirements, the thermal absorptance of this tubing was measured as a function of its environment temperature. We describe the measurement technique and present the results.

  12. Symbolism in J.P. Clark's The Ozidi Saga | Osuagwu | Lwati: A ...

    African Journals Online (AJOL)

    Symbolism in J.P. Clark's The Ozidi Saga. N Osuagwu, E Onyekachi. Abstract. No Abstract. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL ...

  13. JP-3 gene polymorphism in a healthy population of Serbia and ...

    Indian Academy of Sciences (India)

    Unknown

    sions are the cause of Huntington disease like-2 (HDL-2) phenotype. CTG repeats in ... Analyses of CTG repeat polymorphism of JP-3 gene in various healthy populations could help in estimating ... of a recently described membrane protein family exclu- .... low frequency of larger alleles in German population based on very ...

  14. Electronic transport behavior of diameter-graded Ag nanowires

    International Nuclear Information System (INIS)

    Wang Xuewei; Yuan Zhihao

    2010-01-01

    Ag nanowires with a graded diameter in anodic aluminum oxide (AAO) membranes were fabricated by the direct-current electrodeposition. The Ag nanowires have a graded-change in diameter from 8 to 32 nm, which is matched with the graded-change of the AAO pore diameter. Electronic transport measurements show that there is a transport behavior similar to that of a metal-semiconductor junction along the axial direction in the diameter-graded Ag nanowires. Such a novel homogeneous nanojunction will be of great fundamental and practical significance.

  15. Electronic transport behavior of diameter-graded Ag nanowires

    Science.gov (United States)

    Wang, Xue Wei; Yuan, Zhi Hao

    2010-05-01

    Ag nanowires with a graded diameter in anodic aluminum oxide (AAO) membranes were fabricated by the direct-current electrodeposition. The Ag nanowires have a graded-change in diameter from 8 to 32 nm, which is matched with the graded-change of the AAO pore diameter. Electronic transport measurements show that there is a transport behavior similar to that of a metal-semiconductor junction along the axial direction in the diameter-graded Ag nanowires. Such a novel homogeneous nanojunction will be of great fundamental and practical significance.

  16. LncRNA MT1JP functions as a ceRNA in regulating FBXW7 through competitively binding to miR-92a-3p in gastric cancer.

    Science.gov (United States)

    Zhang, Gang; Li, Shuwei; Lu, Jiafei; Ge, Yuqiu; Wang, Qiaoyan; Ma, Gaoxiang; Zhao, Qinghong; Wu, Dongdong; Gong, Weida; Du, Mulong; Chu, Haiyan; Wang, Meilin; Zhang, Aihua; Zhang, Zhengdong

    2018-05-02

    Emerging evidence has shown that dysregulation function of long non-coding RNAs (lncRNAs) implicated in gastric cancer (GC). However, the role of the differentially expressed lncRNAs in GC has not fully explained. LncRNA expression profiles were determined by lncRNA microarray in five pairs of normal and GC tissues, further validated in another 75 paired tissues by quantitative real-time PCR (qRT-PCR). Overexpression of lncRNA MT1JP was conducted to assess the effect of MT1JP in vitro and in vivo. The biological functions were demonstrated by luciferase reporter assay, western blotting and rescue experiments. LncRNA MT1JP was significantly lower in GC tissues than adjacent normal tissues, and higher MT1JP was remarkably related to lymph node metastasis and advance stage. Besides, GC patients with higher MT1JP expression had a well survival. Functionally, overexpression of lncRNA MT1JP inhibited cell proliferation, migration, invasion and promoted cell apoptosis in vitro, and inhibited tumor growth and metastasis in vivo. Functional analysis showed that lncRNA MT1JP regulated FBXW7 expression by competitively binding to miR-92a-3p. MiR-92a-3p and down-regulated FBXW7 reversed cell phenotypes caused by lncRNA MT1JP by rescue analysis. MT1JP, a down-regulated lncRNA in GC, was associated with malignant tumor phenotypes and survival of GC. MT1JP regulated the progression of GC by functioning as a competing endogenous RNA (ceRNA) to competitively bind to miR-92a-3p and regulate FBXW7 expression. Our study provided new insight into the post-transcriptional regulation mechanism of lncRNA MT1JP, and suggested that MT1JP may act as a potential therapeutic target and prognosis biomarker for GC.

  17. Design and Implementation of Enhanced Smart Energy Metering System

    Directory of Open Access Journals (Sweden)

    Oday A.L.A Ridha

    2017-03-01

    Full Text Available In this work, the design and implementation of a smart energy metering system has been developed. This system consists of two parts: billing center and a set of distributed smart energy meters. The function of smart energy meter is measuring and calculating the cost of consumed energy according to a multi-tariff scheme. This can be effectively solving the problem of stressing the electrical grid and rising consumer awareness. Moreover, smart energy meter decreases technical losses by improving power factor. The function of the billing center is to issue a consumer bill and contributes in locating the irregularities on the electrical grid (non-technical losses. Moreover, it sends the switch off command in case of the consumer bill is not paid. For implementation of smart energy meter, the microcontroller (PIC 18F45K22 is used. For communication between billing center and smart energy meters, ZigBee technology is adopted. The necessary program for smart energy meter is written in MicroC PRO, while the program for billing center is written in visual C#.

  18. Blood glucose meters employing dynamic electrochemistry are stable against hematocrit interference in a laboratory setting.

    Science.gov (United States)

    Pfützner, Andreas; Musholt, Petra B; Schipper, Christina; Demircik, Filiz; Hengesbach, Carina; Flacke, Frank; Sieber, Jochen; Forst, Thomas

    2013-11-01

    Hematocrit (HCT) is known to be a confounding factor that interferes with many blood glucose (BG) measurement technologies, resulting in wrong readings. Dynamic electrochemistry has been identified as one possible way to correct for these potential deviations. The purpose of this laboratory investigation was to assess the HCT stability of four BG meters known to employ dynamic electrochemistry (BGStar and iBGStar, Sanofi; Wavesense Jazz, AgaMatrix; Wellion Linus, MedTrust) in comparison with three other devices (GlucoDock, Medisana; OneTouch Verio Pro, LifeScan; FreeStyle Freedom InsuLinx, Abbott-Medisense). Venous heparinized blood was immediately aliquoted after draw and manipulated to contain three different BG concentrations (60-90, 130-160, and 280-320 mg/dl) and five different HCT levels (25%, 35%, 45%, 55%, and 60%). After careful oxygenation to normal blood oxygen pressure, each of the resulting 15 different samples was measured six times with three devices and three strip lots of each meter. The YSI Stat 2300 served as laboratory reference method. Stability to HCT influence was assumed when less than 10% difference occurred between the highest and lowest mean glucose deviations in relation to HCT concentrations [hematocrit interference factor (HIF)]. Five of the investigated self-test meters showed a stable performance with the different HCT levels tested in this investigation: BGStar (HIF 4.6%), iBGStar (6.6%), Wavesense Jazz (4.1%), Wellion Linus (8.5%), and OneTouch Verio Pro (6.2%). The two other meters were influenced by HCT (FreeStyle InsuLinx 17.8%; GlucoDock 46.5%). In this study, meters employing dynamic electrochemistry, as used in the BGStar and iBGStar devices, were shown to correct for potential HCT influence on the meter results. Dynamic electrochemistry appears to be an effective way to handle this interfering condition. © 2013 Diabetes Technology Society.

  19. Blood Glucose Meters Employing Dynamic Electrochemistry Are Stable against Hematocrit Interference in a Laboratory Setting

    Science.gov (United States)

    Pfützner, Andreas; Musholt, Petra B.; Schipper, Christina; Demircik, Filiz; Hengesbach, Carina; Flacke, Frank; Sieber, Jochen; Forst, Thomas

    2013-01-01

    Background Hematocrit (HCT) is known to be a confounding factor that interferes with many blood glucose (BG) measurement technologies, resulting in wrong readings. Dynamic electrochemistry has been identified as one possible way to correct for these potential deviations. The purpose of this laboratory investigation was to assess the HCT stability of four BG meters known to employ dynamic electrochemistry (BGStar and iBGStar, Sanofi; Wavesense Jazz, AgaMatrix; Wellion Linus, MedTrust) in comparison with three other devices (GlucoDock, Medisana; OneTouch Verio Pro, LifeScan; FreeStyle Freedom InsuLinx, Abbott-Medisense). Methods Venous heparinized blood was immediately aliquoted after draw and manipulated to contain three different BG concentrations (60–90, 130–160, and 280–320 mg/dl) and five different HCT levels (25%, 35%, 45%, 55%, and 60%). After careful oxygenation to normal blood oxygen pressure, each of the resulting 15 different samples was measured six times with three devices and three strip lots of each meter. The YSI Stat 2300 served as laboratory reference method. Stability to HCT influence was assumed when less than 10% difference occurred between the highest and lowest mean glucose deviations in relation to HCT concentrations [hematocrit interference factor (HIF)]. Results Five of the investigated self-test meters showed a stable performance with the different HCT levels tested in this investigation: BGStar (HIF 4.6%), iBGStar (6.6%), Wavesense Jazz (4.1%), Wellion Linus (8.5%), and OneTouch Verio Pro (6.2%). The two other meters were influenced by HCT (FreeStyle InsuLinx 17.8%; GlucoDock 46.5%). Conclusions In this study, meters employing dynamic electrochemistry, as used in the BGStar and iBGStar devices, were shown to correct for potential HCT influence on the meter results. Dynamic electrochemistry appears to be an effective way to handle this interfering condition. PMID:24351179

  20. Development of the liquid level meters for the PandaX dark matter detector

    International Nuclear Information System (INIS)

    Hu Jie; Gong Haowei; Lin Qing; Ni Kaixuan; Wei Yuehuan; Xiao Mengjiao; Xiao Xiang; Zhao Li; Tan Andi

    2014-01-01

    The two-phase xenon detector is at the frontier of dark matter direct search. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level needs to be monitored and controlled in sub-millimeter precision. In this paper, we present a detailed design and study of two kinds of level meters for the PandaX dark matter detector. The long level meter is used to monitor the overall liquid level while short level meters are used to monitor the inclination of the detector. These level meters are cylindrical capacitors that are custom-made from two concentric metal tubes. Their capacitance values are read out by a universal transducer interface chip and are recorded by the PandaX slow control system. We present the developments that lead to level meters with long-term stability and sub-millimeter precision. Fluctuations (standard deviations) of less than 0.02 mm for the short level meters and less than 0.2 mm for the long level meter were achieved during a few days of test operation. (authors)

  1. Comprehensive evaluation of the Berthold LB1200 survey meter

    International Nuclear Information System (INIS)

    Davis, M.W.

    1986-05-01

    The performance of two Berthod LB1200 survey meters was evaluated under the influence of a range of beta and photon radiation energies and environmental conditions likely to be encountered in the field. The survey meters responded satisfactorily to the range of beta particle and photon radiation energies emitted by most radioisotopes commonly used in Canada. The survey meters performed acceptably under most of the environmental conditions tested here with the exception of radiofrequency interference and electrostatic charge

  2. UVB-induced gene expression in the skin of Xiphophorus maculatus Jp 163 B☆

    Science.gov (United States)

    Yang, Kuan; Boswell, Mikki; Walter, Dylan J.; Downs, Kevin P.; Gaston-Pravia, Kimberly; Garcia, Tzintzuni; Shen, Yingjia; Mitchell, David L.; Walter, Ronald B.

    2014-01-01

    Xiphophorus fish and interspecies hybrids represent long-standing models to study the genetics underlying spontaneous and induced tumorigenesis. The recent release of the Xiphophorus maculatus genome sequence will allow global genetic regulation studies of genes involved in the inherited susceptibility to UVB-induced melanoma within select backcross hybrids. As a first step toward this goal, we report results of an RNA-Seq approach to identify genes and pathways showing modulated transcription within the skin of X. maculatus Jp 163 B upon UVB exposure. X. maculatus Jp 163 B were exposed to various doses of UVB followed by RNA-Seq analysis at each dose to investigate overall gene expression in each sample. A total of 357 genes with a minimum expression change of 4-fold (p-adj fish skin to UVB exposure. PMID:24556253

  3. Device for film deposition and implantation of ions inside pipes of low diameter

    International Nuclear Information System (INIS)

    Pogrebnjak, A.D.; Perekrjostov, V.I.; Tyurin, Yu.N.; Wood, B.P.

    2002-01-01

    Two principally new devices, which can be applied to deposit coatings inside the pipes of low diameter, have been developed. The thickness of coatings and films can be varied. To deposit coatings of a low thickness (about 2 nm) on inside pipe walls using a vacuum-arc source and a sputtering device, which is composed of the pipe applied for anode cooling, the constant magnet, the magnetic circuit, the anode, the cathode, the pipe subjected for coating deposition, the cathode holder, etc. Using this device, we have deposited TiC, Ta, Cr, TiN coatings of various thickness ranging from scores of nano-meters to several micro-meters and with very good adhesion to the substrate. To increase adhesion, we applied 10 to 20 kV voltage during ion implantation to the substrate. To study element and structure composition, we applied RBS, TEM, SEM, XRD analyses, micro-hardness, wear resistance tests and also those for corrosion resistance in acid media. Another version of the source was based on the pulsed plasma-detonation technology and applied an evaporating electrode (for implantation) and a powder, which was injected into a plasma jet. The jet velocity reached several kilometers per second. Current of several kilo-amps passed through the plasma jet and increased its energy. The produced in this way coating thickness reached 30 to 400 micro-meter. Application of the vacuum-arc source for subsequent coating deposition allowed us to improve the servicing characteristics of surface layers. We have deposited NiAl, CoAl, A1 2 O 3 , WC-Co, Hastelloy and stainless steel SS316L

  4. Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.

    Science.gov (United States)

    Duc, Sebastien; Villerius, Vincent; Bertucci, William; Grappe, Frederic

    2007-09-01

    The ErgomoPro (EP) is a power meter that measures power output (PO) during outdoor and indoor cycling via 2 optoelectronic sensors located in the bottom bracket axis. The aim of this study was to determine the validity and the reproducibility of the EP compared with the SRM crank set and Powertap hub (PT). The validity of the EP was tested in the laboratory during 8 submaximal incremental tests (PO: 100 to 400 W), eight 30-min submaximal constant-power tests (PO = 180 W), and 8 sprint tests (PO > 750 W) and in the field during 8 training sessions (time: 181 +/- 73 min; PO: approximately 140 to 160 W). The reproducibility was assessed by calculating the coefficient of PO variation (CV) during the submaximal incremental and constant tests. The EP provided a significantly higher PO than the SRM and PT during the submaximal incremental test: The mean PO differences were +6.3% +/- 2.5% and +11.1% +/- 2.1% respectively. The difference was greater during field training sessions (+12.0% +/- 5.7% and +16.5% +/- 5.9%) but lower during sprint tests (+1.6% +/- 2.5% and +3.2% +/- 2.7%). The reproducibility of the EP is lower than those of the SRM and PT (CV = 4.1% +/- 1.8%, 1.9% +/- 0.4%, and 2.1% +/- 0.8%, respectively). The EP power meter appears less valid and reliable than the SRM and PT systems.

  5. Integration of auditory and tactile inputs in musical meter perception.

    Science.gov (United States)

    Huang, Juan; Gamble, Darik; Sarnlertsophon, Kristine; Wang, Xiaoqin; Hsiao, Steven

    2013-01-01

    Musicians often say that they not only hear but also "feel" music. To explore the contribution of tactile information to "feeling" music, we investigated the degree that auditory and tactile inputs are integrated in humans performing a musical meter-recognition task. Subjects discriminated between two types of sequences, "duple" (march-like rhythms) and "triple" (waltz-like rhythms), presented in three conditions: (1) unimodal inputs (auditory or tactile alone); (2) various combinations of bimodal inputs, where sequences were distributed between the auditory and tactile channels such that a single channel did not produce coherent meter percepts; and (3) bimodal inputs where the two channels contained congruent or incongruent meter cues. We first show that meter is perceived similarly well (70-85 %) when tactile or auditory cues are presented alone. We next show in the bimodal experiments that auditory and tactile cues are integrated to produce coherent meter percepts. Performance is high (70-90 %) when all of the metrically important notes are assigned to one channel and is reduced to 60 % when half of these notes are assigned to one channel. When the important notes are presented simultaneously to both channels, congruent cues enhance meter recognition (90 %). Performance dropped dramatically when subjects were presented with incongruent auditory cues (10 %), as opposed to incongruent tactile cues (60 %), demonstrating that auditory input dominates meter perception. These observations support the notion that meter perception is a cross-modal percept with tactile inputs underlying the perception of "feeling" music.

  6. Clinical utility of Abbott Precision Xceed Pro® ketone meter in diabetic patients.

    Science.gov (United States)

    Yu, Hoi-Ying Elsie; Agus, Michael; Kellogg, Mark D

    2011-11-01

    Diagnosis and management of diabetic ketoacidosis (DKA) often rely on the measurement of urine ketones along with blood glucose, anion gap, and pH. These values, however, do not reliably reflect the severity of ketoacidosis. The Abbott Precision Xceed Pro® meter is an FDA-approved device that quantitatively measures β-hydroxybutyrate (BOH) in whole blood. This study was undertaken to determine whether the ketone meter meets the analytical criteria to aid DKA diagnosis and management in the hospital. 54 heparinized venous whole blood BOH concentrations from 27 diabetic patients were measured by the Abbott meter, and compared with the plasma BOH concentrations measured with Stanbio reagent (reference method). Measurements were done in the hospital central laboratory. Of the 54 pairs of specimens analyzed, 17 pairs displayed a difference of >15% between the two methods. Nearly all discrepant points occurred when BOH >5 mmol/L (reference method). Linearity evaluation revealed that the meter is not linear from 0.0 to 8.0 mmol/L, contrary to the claim by the manufacturer. Further, we identified acetoacetate, a metabolite commonly present in DKA patients, as a potential interfering substance for the meter BOH measurement. BOH measurements by the Abbott meter up to 3 mmol/L correlate well with the reference method, but become discrepant above that point. While this characteristic may be useful in the diagnosis of DKA, it may not allow clinicians to serially follow the response to therapy in hospitalized DKA patients with BOH values greater than 5 mmol/L (reference method). © 2011 John Wiley & Sons A/S.

  7. Conducted interference on smart meters

    NARCIS (Netherlands)

    Keyer, Cornelis H.A.; Leferink, Frank

    2017-01-01

    The increasing conducted interference caused by modern electronic equipment is causing more problems for electronic, or static, energy meters. These meters are called smart meters when equipped with a communication link, and are replacing the conventional electromechanical meters. It is known that

  8. A clustering analysis of lipoprotein diameters in the metabolic syndrome

    Directory of Open Access Journals (Sweden)

    Frazier-Wood Alexis C

    2011-12-01

    Full Text Available Abstract Background The presence of smaller low-density lipoproteins (LDL has been associated with atherosclerosis risk, and the insulin resistance (IR underlying the metabolic syndrome (MetS. In addition, some research has supported the association of very low-, low- and high-density lipoprotein (VLDL HDL particle diameters with components of the metabolic syndrome (MetS, although this has been the focus of less research. We aimed to explore the relationship of VLDL, LDL and HDL diameters to MetS and its features, and by clustering individuals by their diameters of VLDL, LDL and HDL particles, to capture information across all three fractions of lipoprotein into a unified phenotype. Methods We used nuclear magnetic resonance spectroscopy measurements on fasting plasma samples from a general population sample of 1,036 adults (mean ± SD, 48.8 ± 16.2 y of age. Using latent class analysis, the sample was grouped by the diameter of their fasting lipoproteins, and mixed effects models tested whether the distribution of MetS components varied across the groups. Results Eight discrete groups were identified. Two groups (N = 251 were enriched with individuals meeting criteria for the MetS, and were characterized by the smallest LDL/HDL diameters. One of those two groups, one was additionally distinguished by large VLDL, and had significantly higher blood pressure, fasting glucose, triglycerides, and waist circumference (WC; P Conclusions While small LDL diameters remain associated with IR and the MetS, the occurrence of these in conjunction with a shift to overall larger VLDL diameter may identify those with the highest fasting glucose, TG and WC within the MetS. If replicated, the association of this phenotype with more severe IR-features indicated that it may contribute to identifying of those most at risk for incident type II diabetes and cardiometabolic disease.

  9. Radiofrequency fields associated with the Itron smart meter.

    Science.gov (United States)

    Tell, R A; Sias, G G; Vazquez, A; Sahl, J; Turman, J P; Kavet, R I; Mezei, G

    2012-08-01

    This study examined radiofrequency (RF) emissions from smart electric power meters deployed in two service territories in California for the purpose of evaluating potential human exposure. These meters included transmitters operating in a local area mesh network (RF LAN, ∼250 mW); a cell relay, which uses a wireless wide area network (WWAN, ∼1 W); and a transmitter serving a home area network (HAN, ∼70 mW). In all instances, RF fields were found to comply by a wide margin with the RF exposure limits established by the US Federal Communications Commission. The study included specialised measurement techniques and reported the spatial distribution of the fields near the meters and their duty cycles (typically smart meters as deployed. However, the results are restricted to a single manufacturer's emitters.

  10. Net metering study of switching effects on electromechanical meters[Report prepared for the Measurement Canada Electricity Net Metering Project

    Energy Technology Data Exchange (ETDEWEB)

    Van Overberghe, L. [Measurement Canada, London, ON (Canada)

    2006-03-03

    The feasibility of introducing net metering in the electricity sector was evaluated with particular reference to a project administered by Measurement Canada and Electro-Federation Canada (MicroPower Connect) in collaboration with Natural Resources Canada. The objective of the Measurement Canada Electricity Net Metering Project is to identify and eliminate the barriers introduced by the Electricity and Gas Inspection Act regarding the introduction of net metering. The purpose was to design a device that would allow rotation reversal in a residential electromechanical single phase meter. The device should approximate any fluctuations found in a typical net metering system. A series of tests were conducted to understand the influences, on errors, of forward-to-reverse and reverse-to-forward transitions, specifically to find evidence of error migration and mechanical stress. The project was designed to find and measure the effects of forward reverse switching on an electromechanical meter resulting from a change in energy flow. Twenty metres were calibrated in the forward direction in series from light load to high load. Power factor was not adjustable. Test points were then applied in both the forward and reverse directions. The exercise yielded individual errors which were aggregated to show average found errors after 3,000 transitions. Small shifts in errors were apparent and there was no evidence to support a disk flutter theory. refs., tabs., figs.

  11. Nineteen-Foot Diameter Explosively Driven Blast Simulator; TOPICAL

    International Nuclear Information System (INIS)

    VIGIL, MANUEL G.

    2001-01-01

    This report describes the 19-foot diameter blast tunnel at Sandia National Laboratories. The blast tunnel configuration consists of a 6 foot diameter by 200 foot long shock tube, a 6 foot diameter to 19 foot diameter conical expansion section that is 40 feet long, and a 19 foot diameter test section that is 65 feet long. Therefore, the total blast tunnel length is 305 feet. The development of this 19-foot diameter blast tunnel is presented. The small scale research test results using 4 inch by 8 inch diameter and 2 foot by 6 foot diameter shock tube facilities are included. Analytically predicted parameters are compared to experimentally measured blast tunnel parameters in this report. The blast tunnel parameters include distance, time, static, overpressure, stagnation pressure, dynamic pressure, reflected pressure, shock Mach number, flow Mach number, shock velocity, flow velocity, impulse, flow duration, etc. Shadowgraphs of the shock wave are included for the three different size blast tunnels

  12. Differential effects of two indigenous broilers exposed to cold stress and characters of follicle density and diameter

    Directory of Open Access Journals (Sweden)

    Xing Y. Chen

    2011-02-01

    Full Text Available digenous chickens from various part of China, due to different feather characters, always performed differently when countered with cold stress. In this study, the effects of long term hypothermia on serum hormones (triiodothyronine, thyroxine and insulin and activity of plasma enzymes (Alanine aminotransferase, aspartate aminotransferase, gamma-glutamyltransferase, creatine kinase and lactic dehydrogenase were studied in two indigenous broiler breeds, Huainan partridge (H and Wenchang (W chickens. Chickens in 20°C±2°C were compared with those subjected to moderate (15°C±2°C and severe low temperature (10°C±2°C for one week. Long-term hypothermia elevated plasma insulin and reduced T4 in W, decelerated insulin and increased T4 in H, while T3 did not change in the two breeds. Plasma enzymes AST, LDH and CK decreased in the two breeds and ALT only decreased in W exposed to cold stress. A significantly decreased body weight gain of H and no variations in W at low temperature were observed. However, a trend of decreased weight gain in W was observed when bred under low temperature condition. Follicle density and diameter were compared in the two breeds with back density in H significantly higher than W and diameter from back of H significantly smaller than W, while much larger than the latter at latero-abdominal part. We investigated the pattern of serum biological change, follicle diameter and density under cold stress condition in two indigenous broiler breeds from different areas of China to provide informative guidance for broiler production and indications in breeding of cold resistant breed.

  13. Evaluation of the nugget diameter in spot welded joints between two steel sheets by means of a potential drop technique

    International Nuclear Information System (INIS)

    Tohmyoh, Hironori; Ikarashi, Hidetomo; Matsui, Yoichi; Hasegawa, Yuta; Obara, Satoshi

    2015-01-01

    A potential drop technique which utilizes the electrical circuit used in resistance spot welding is reported. Spot welded samples comprising two steel sheets were inserted between the two Cu electrodes and a constant direct current was supplied between the electrodes. The potential drop between two points, one on each electrode, was determined by analysis for various values of nugget diameter and various values of the contact resistance between the Cu electrodes and the steel sheet sample. The nugget diameter of the spot welded joint could be quantitatively evaluated from the measured potential drop and the equation obtained from the analysis. (paper)

  14. Evaluation of the nugget diameter in spot welded joints between two steel sheets by means of a potential drop technique

    Science.gov (United States)

    Tohmyoh, Hironori; Ikarashi, Hidetomo; Matsui, Yoichi; Hasegawa, Yuta; Obara, Satoshi

    2015-08-01

    A potential drop technique which utilizes the electrical circuit used in resistance spot welding is reported. Spot welded samples comprising two steel sheets were inserted between the two Cu electrodes and a constant direct current was supplied between the electrodes. The potential drop between two points, one on each electrode, was determined by analysis for various values of nugget diameter and various values of the contact resistance between the Cu electrodes and the steel sheet sample. The nugget diameter of the spot welded joint could be quantitatively evaluated from the measured potential drop and the equation obtained from the analysis.

  15. Smart Meter Data Analytics: Systems, Algorithms and Benchmarking

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Golab, Lukasz; Golab, Wojciech

    2016-01-01

    the proposed benchmark using five representative platforms: a traditional numeric computing platform (Matlab), a relational DBMS with a built-in machine learning toolkit (PostgreSQL/MADlib), a main-memory column store (“System C”), and two distributed data processing platforms (Hive and Spark/Spark Streaming......Smart electricity meters have been replacing conventional meters worldwide, enabling automated collection of fine-grained (e.g., every 15 minutes or hourly) consumption data. A variety of smart meter analytics algorithms and applications have been proposed, mainly in the smart grid literature......-line feature extraction and model building as well a framework for on-line anomaly detection that we propose. Second, since obtaining real smart meter data is difficult due to privacy issues, we present an algorithm for generating large realistic data sets from a small seed of real data. Third, we implement...

  16. Fundamental studies on miniature dose meter using variable capacitance Si-diode

    International Nuclear Information System (INIS)

    Inoue, Yoshio

    1976-01-01

    The results of fundamental studies on development of a miniature dose meter using a semiconductor applicable for dosimetry in both intracavitary and external radiotherapy are described. Many different instruments have been applied in clinical dosimetry for regional lesions, mostly in phantom studies, e. g. the small sized ionization chamber, the fluoroluminescence glass dose meter and the thermoluminescence dose meter. However, there are considerable problems regarding safety, reproducibility, and simplicity for regional dosimetry of intracavitary lesions, such as genitourinary, gastrointestinal and respiratory malignancies. To overcome these problems, an attempt was made to develop a miniature catheter type detector using a variable capacitance Si-diode for gamma ray dosimetry. The newly developed miniature dose meter using a semiconductor has the following characteristics. As the tip of detector (23mm long and 3mm in diameter) is very small, the apparatus unit is easy to manipulate in the dosimetry of intracavitary lesions. As no voltage is supplied to the detector, there is no danger of electric shock from in vivo studies. A strict linearity existed between the radiation dose rate and the generated voltage even when the range of experimental irradiation dose rate was extremely wide. The sensitivity of the detector was affected by the environmental temperature, but it was easy to correct the sensitivity by applying a special calibration chart to the value derived from a thermister enclosed in the detector. Even with the experimental irradiation of more than 50,000R, no changes in the sensitivity of the detector were observed. Thus, the durability of the apparatus was shown to be excellent. (auth.)

  17. Turbulent Coolant Dispersion in the Wake of a Turbine Vane Trailing Edge

    Science.gov (United States)

    2015-01-01

    streak injection point. A bulk flow of 0.3 liters per minute supplies the three hot streaks, which are individually metered to ensure isokinetic ...the model sizes are limited to tens of centimeters, with flow velocities of a few meters per second. The Prandtl and Schmidt numbers of the working...channel illustrated in Figures 2.7, 2.8 and 2.9. Metered flow is delivered to the apparatus through a 38 mm diameter hose. Two successive diffusing

  18. Two-phase fluid flow measurements in small diameter channels using real-time neutron radiography

    International Nuclear Information System (INIS)

    Carlisle, B.S.; Johns, R.C.; Hassan, Y.A.

    2004-01-01

    A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)

  19. A Simple Method for Measuring the Verticality of Small-Diameter Driven Wells

    DEFF Research Database (Denmark)

    Kjeldsen, Peter; Skov, Bent

    1994-01-01

    The presence of stones, solid waste, and other obstructions can deflect small-diameter driven wells during installation, leading to deviations of the well from its intended position. This could lead to erroneous results, especially for measurements of ground water levels by water level meters....... A simple method was developed to measure deviations from the intended positions of well screens and determine correction factors required for proper measurement of ground water levels in nonvertical wells. The method is based upon measurement of the hydrostatic pressure in the bottom of a water column...... ground water flow directions....

  20. A new kind high-reliability digital reactivity meter

    International Nuclear Information System (INIS)

    Shen Feng; Jiang Zongbing

    2001-01-01

    The paper introduces a new kind of high-reliability Digital Reactivity Meter developed by the DRM developing group in designing department of Nuclear Power Institute of China. The meter has two independent measure channels, which can be set as either master-slave structure or working independently. This structure will ensure that the meter can continually fulfill its online measure task under the condition of single failure with it. It provides a solution for the conflict between nuclear station's extreme demand in DRM's reliability and instability of computer's business software platform. The instrument reaches both advance and reliability by covering a lot of kinds of complex functions in data process and display

  1. Dominant height-based height-diameter equations for trees in southern Indiana

    Science.gov (United States)

    John A., Jr. Kershaw; Robert C. Morrissey; Douglass F. Jacobs; John R. Seifert; James B. McCarter

    2008-01-01

    Height-diameter equations are developed based on dominant tree data collected in 1986 in 8- to 17-year-old clearcuts and the phase 2 Forest Inventory and Analysis plots on the Hoosier National Forest in south central Indiana. Two equation forms are explored: the basic, three-parameter Chapman-Richards function, and a modification of the three-parameter equation...

  2. Air Compressibility Effect on Bouwer and Rice Seepage Meter.

    Science.gov (United States)

    Peng, Xin; Zhan, Hongbin

    2017-11-01

    Measuring a disconnected streambed seepage flux using a seepage meter can give important streambed information and help understanding groundwater-surface water interaction. In this study, we provide a correction for calculating the seepage flux rate with the consideration of air compressibility inside the manometer of the Bouwer and Rice seepage meter. We notice that the effect of air compressibility in the manometer is considerably larger when more air is included in the manometer. We find that the relative error from neglecting air compressibility can be constrained within 5% if the manometer of the Bouwer and Rice seepage meter is shorter than 0.8 m and the experiment is done in a suction mode in which air is pumped out from the manometer before the start of measurement. For manometers longer than 0.8 m, the relative error will be larger than 5%. It may be over 10% if the manometer height is longer than 1.5 m and the experiment is done in a no-suction mode, in which air is not pumped out from the manometer before the start of measurement. © 2017, National Ground Water Association.

  3. Relative accuracy of the BD Logic and FreeStyle blood glucose meters.

    Science.gov (United States)

    2007-04-01

    The BD Logic((R)) (Becton, Dickinson and Co., Franklin Lakes, NJ) and FreeStyle((R)) (Abbott Diabetes Care, Alameda, CA) meters are used to transmit data directly to insulin pumps for calculation of insulin doses and to calibrate continuous glucose sensors as well as to monitor blood glucose levels. The accuracy of the two meters was evaluated in two inpatient studies conducted by the Diabetes Research in Children Network (DirecNet). In both studies, meter glucose measurements made with either venous or capillary blood were compared with reference glucose measurements made by the DirecNet Central Laboratory at the University of Minnesota using a hexokinase enzymatic method. The BD Logic tended to read lower than the laboratory reference regardless of whether venous (median difference = -9 mg/dL) or capillary blood (median difference = -7 mg/dL) was used. This resulted in lower accuracy of the BD Logic compared with the FreeStyle meter based on the median relative absolute difference (RAD) for both venous blood (median RAD, 9% vs. 5%, P blood (median RAD, 11% vs. 6%, P = 0.008). The greatest discrepancy in the performance of the two meters was at higher reference glucose values. Accuracy was not significantly different when the reference was < or = 70 mg/dL. The BD Logic meter is less accurate than the FreeStyle meter.

  4. Optical spectroscopy of iodine-doped single-wall carbon nanotubes of different diameter

    International Nuclear Information System (INIS)

    Tonkikh, Alexander A.; Obraztsova, Elena D.; Pozharov, Anatolii S.; Obraztsova, Ekaterina A.; Belkin, Alexey V.

    2012-01-01

    Single-wall carbon nanotubes with polyiodide chains inside are interesting from two points of view. According to predictions, first, the iodine structure type inside the nanotube is determined by the nanotube geometry. Second, after iodination all nanotubes become metallic. In this work, we made an attempt to check both predictions. To study the diameter-dependent properties we have taken for a gas-phase iodination the pristine single-wall carbon nanotubes grown by three different techniques providing a different average diameter: a chemical vapor deposition with a Co/Mo catalyst (CoMoCat) with a diameter range (0.6-1.3) nm, a high-pressure CO decomposition (HiPCO) - a diameter range (0.8-1.5) nm, and an aerosol technique with Fe catalyst - a diameter range (1.3-2.0) nm. The Raman spectra have shown a complication of the polyiodide chain structure while the nanotube diameter increased. The optical spectroscopy data (a suppression of E 11 band in the UV-Vis-NIR absorption spectrum) have confirmed the theoretical prediction about transformation of all nanotubes into metallic phase after doping. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Diameter-speed relation of sprite streamers

    International Nuclear Information System (INIS)

    Kanmae, T; Stenbaek-Nielsen, H C; McHarg, M G; Haaland, R K

    2012-01-01

    Propagation and splitting of sprite streamers has been observed at high temporal and spatial resolution using two intensified high-speed CMOS cameras recording at 10 000 and 16 000 frames per second. Concurrent video recordings from a remote site provided data for triangulation allowing us to determine accurate altitude scales for the sprites. Diameters and speeds of the sprite streamers were measured from the high-speed images, and the diameters were scaled to the reduced diameters based on the triangulated locations. The sprite streamers with larger reduced diameter move faster than those with smaller diameter; the relation between the reduced diameter and speed is roughly linear. The reduced diameters at ≈65-70 km altitude are larger than streamer diameters measured at ground pressure in laboratory discharges indicating a deviation from the similarity law possibly due to the effects of the photoionization and an expansion of the streamer head along its propagation over a long distance. The reduced diameter and speed of the sprite streamers agree well with the diameter-velocity relation proposed by Naidis (2009 Phys. Rev. E 79 057401), and the peak electric field of the sprite streamers is estimated to be approximately 3-5 times the breakdown threshold field. (paper)

  6. Frictional pressure drop of steam-water two-phase flow in helical coils with small helix diameter of HTR-10

    International Nuclear Information System (INIS)

    Bi Qincheng; Chen Tingkuan; Luo Yushan; Zheng Jianxue

    1996-01-01

    Experiments of steam-water two-phase flow frictional pressure drop through five vertically and horizontally positioned helical coils were carried out in the high pressure steam water test loop of Xi'an Jiaotong University. Two kinds of tube with inner diameters of 10 mm and 12 mm were used to form the coils. The helix diameter was 115 mm with coil pitch 22.5 mm. The experimental conditions were: pressure p = 4-14 MPa, mass velocity G = 400-2000 kg/(m 2 ·s), and inner wall heat flux q = 0-750 kW/m 2 . Theoretical analysis with a semi-empirical correlation was made to predict the two-phase flow fictional pressure drop through these kinds of helical coils

  7. Radiofrequency fields associated with the Itron smart meter

    International Nuclear Information System (INIS)

    Tell, R. A.; Sias, G. G.; Vazquez, A.; Sahl, J.; Turman, J. P.; Kavet, R. I.; Mezei, G.

    2008-01-01

    This study examined radiofrequency (RF) emissions from smart electric power meters deployed in two service territories in California for the purpose of evaluating potential human exposure. These meters included transmitters operating in a local area mesh network (RF LAN, ∼250 mW); a cell relay, which uses a wireless wide area network (WWAN, ∼1 W); and a transmitter serving a home area network (HAN, ∼70 mW). In all instances, RF fields were found to comply by a wide margin with the RF exposure limits established by the US Federal Communications Commission. The study included specialised measurement techniques and reported the spatial distribution of the fields near the meters and their duty cycles (typically <1 %) whose value is crucial to assessing time-averaged exposure levels. This study is the first to characterise smart meters as deployed. However, the results are restricted to a single manufacturer's emitters. (authors)

  8. Fundamental principles of rotary displacement meters

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, J. [Schlumberger Industries, Owenton, KY (United States)

    1995-12-01

    The gas meter exists to continually and accurately measure the volume of gas supplied over the complete flow range of the load. In effect the gas meter serves as the {open_quotes}cash register{close_quotes} of the gas industry; its accurate and dependable performance ensures fair dealings for both the supplier and the user. An investment both in and of itself, the gas meter should be chosen as a function of its usefullness both over the short term and the long term. Thus in addition to initial cost, one must take into account various associated factors, costs and benefits, including the following: Design Characteristics Application, suitability, Meter features and options, Operation constraints, Installation, Service and maintenance, Repair and replacement, Life expectancy, Compatibility with complimentary products, Correcting devices, Remote reading capabilities, Data generation and gathering, Upgradeabilty. This paper will look at one positive displacement meter, the Rotary meter, and address the fundamentals principals of the technology as well as looking at some of the benefits derived from its application. Rotary positive displacement meters were introduced at the end of last century. Used primarily for metering transmission sized loads, the meters` measuring capabilities have extended to cover nearly all areas of distribution with exception of domestic applications. Rotary meters are available in rated capacities from 800 cfh to 102,000 cfh and operating pressures from 175 PSIG to 1440 PSIG. The use of rotary meters on load ranges in the 800 to 10,000 cfh category has increased and is replacing the use of diaphragm meters because of the smaller relative size of rotaries, and improvements in rangeabilities in the last few years. Turbine meters are usually the meter of choice on loads over 16,000 cfh unless a meter with high rangeability is required because of varying load characteristics, in which case a large foot mounted rotary might still be selected.

  9. Application research of improved 235U enrichment meter

    International Nuclear Information System (INIS)

    Liu Daming; Wu Xin; Lu Zhao; Tang Peijia; Lu Feng; Wang Yunmei

    1998-01-01

    A prototype 235 U enrichment meter based on NaI(Tl) γ spectroscopy is improved and it works under the principle of that the enrichment of 235 U is proportional to the radioactivity of 185 keV γ-ray when the sample is thick infinitely. The data of radioactivity from 235 U can be collected by a notebook computer and the interface control software is written using C++ language. The meter was tested and calibrated using standard fuel rods in fuel fabrication plant. For single fuel rod, the measured value of 235 U enrichment is agreeable with declared value within-1.0%-2.8%

  10. Digital temperature meter

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S

    1982-01-01

    Digital temperature meter for precise temperature measurements is presented. Its parts such as thermostat, voltage-frequency converter and digital frequency meter are described. Its technical parameters such as temperature range 50degC-700degC, measurement precision 1degC, measurement error +-1degC are given. (A.S.).

  11. Ultrasonic flow meter

    NARCIS (Netherlands)

    Lötters, Joost Conrad; Snijders, G.J.; Volker, A.W.F.

    2014-01-01

    The invention relates to an ultrasonic flow meter comprising a flow tube for the fluid whose flow rate is to be determined. The flow meter comprises a transmitting element for emitting ultrasonic waves, which is provided on the outer jacket of the flow tube. A receiving element, which is provided on

  12. REM meter for pulsed sources of neutrons

    International Nuclear Information System (INIS)

    Thorngate, J.E.; Hunt, G.F.; Rueppel, D.W.

    1980-01-01

    A rem meter was constructed specifically for measuring neutrons produced by fusion experiments for which the source pulses last 10 ms or longer. The detector is a 6 Li glass scintillator, 25.4 mm in diameter and 3.2 mm thick, surrounded by 11.5 cm of polyethylene. This detector has a sensitivity of 8.5 x 10 4 counts/mrem. The signals from this fast scintillator are shaped using a shorted delay line to produce pulses that are only 10 ns long so that dose equivalent rates up to 12 mrem/s can be measured with less than a 1% counting loss. The associated electronic circuits store detector counts only when the count rate exceeds a preset level. When the count rate returns to background, a conversion from counts to dose equivalent is made and the results are displayed. As a means of recording the number of source pulses that have occurred, a second display shows how many times the preset count rate has been exceeded. Accumulation of detector counts and readouts can also be controlled manually. The unit will display the integrated dose equilavent up to 200 mrem in 0.01 mrem steps. A pulse-height discriminator rejects gamma-ray interactions below 1 MeV, and the detector size limits the response above that energy. The instrument can be operated from an ac line or will run on rechargeable batteries for up to 12 hours

  13. Federal Building Metering Guidance (per 42 U.S.C. 8253(e), Metering of Energy Use)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-11-01

    Guidance defines which federal buildings are appropriate to meter, provides metering prioritization recommendations for agencies with limited resources, and discusses the requirement for agencies to submit metering implementation plans to the U.S. Department of Energy.

  14. Rotor instrumentation circuits for the Sandia 34-meter vertical axis wind turbine

    Science.gov (United States)

    Sutherland, Herbert J.; Stephenson, William A.

    1988-07-01

    Sandia National Laboratories has erected a research oriented, 34-meter diameter, Darrieus vertical axis wind turbine near Bushland, Texas, which has been designated the Sandia 34-m VAWT Test Bed. To meet present and future research needs, the machine was equipped with a large array of sensors. This manuscript details the sensors initially placed on the rotor, their respective instrumentation circuits, and the provisions incorporated into the design of the rotor instrumentation circuits for future research. This manuscript was written as a reference manual for the rotor instrumentation of the Test Bed.

  15. Biomechanical evaluation of one-piece and two-piece small-diameter dental implants: In-vitro experimental and three-dimensional finite element analyses.

    Science.gov (United States)

    Wu, Aaron Yu-Jen; Hsu, Jui-Ting; Chee, Winston; Lin, Yun-Te; Fuh, Lih-Jyh; Huang, Heng-Li

    2016-09-01

    Small-diameter dental implants are associated with a higher risk of implant failure. This study used both three-dimensional finite-element (FE) simulations and in-vitro experimental tests to analyze the stresses and strains in both the implant and the surrounding bone when using one-piece (NobelDirect) and two-piece (NobelReplace) small-diameter implants, with the aim of understanding the underlying biomechanical mechanisms. Six experimental artificial jawbone models and two FE models were prepared for one-piece and two-piece 3.5-mm diameter implants. Rosette strain gauges were used for in-vitro tests, with peak values of the principal bone strain recorded with a data acquisition system. Implant stability as quantified by Periotest values (PTV) were also recorded for both types of implants. Experimental data were analyzed statistically using Wilcoxon's rank-sum test. In FE simulations, the peak value and distribution of von-Mises stresses in the implant and bone were selected for evaluation. In in-vitro tests, the peak bone strain was 42% lower for two-piece implants than for one-piece implants. The PTV was slightly lower for one-piece implants (PTV = -6) than for two-piece implants (PTV = -5). In FE simulations, the stresses in the bone and implant were about 23% higher and 12% lower, respectively, for one-piece implants than those for two-piece implants. Due to the higher peri-implant bone stresses and strains, one-piece implants (NobelDirect) might be not suitable for use as small-diameter implants. Copyright © 2016. Published by Elsevier B.V.

  16. Simple, inexpensive computerized rodent activity meters.

    Science.gov (United States)

    Horton, R M; Karachunski, P I; Kellermann, S A; Conti-Fine, B M

    1995-10-01

    We describe two approaches for using obsolescent computers, either an IBM PC XT or an Apple Macintosh Plus, to accurately quantify spontaneous rodent activity, as revealed by continuous monitoring of the spontaneous usage of running activity wheels. Because such computers can commonly be obtained at little or no expense, and other commonly available materials and inexpensive parts can be used, these meters can be built quite economically. Construction of these meters requires no specialized electronics expertise, and their software requirements are simple. The computer interfaces are potentially of general interest, as they could also be used for monitoring a variety of events in a research setting.

  17. Method of synthesizing small-diameter carbon nanotubes with electron field emission properties

    Science.gov (United States)

    Liu, Jie (Inventor); Du, Chunsheng (Inventor); Qian, Cheng (Inventor); Gao, Bo (Inventor); Qiu, Qi (Inventor); Zhou, Otto Z. (Inventor)

    2009-01-01

    Carbon nanotube material having an outer diameter less than 10 nm and a number of walls less than ten are disclosed. Also disclosed are an electron field emission device including a substrate, an optionally layer of adhesion-promoting layer, and a layer of electron field emission material. The electron field emission material includes a carbon nanotube having a number of concentric graphene shells per tube of from two to ten, an outer diameter from 2 to 8 nm, and a nanotube length greater than 0.1 microns. One method to fabricate carbon nanotubes includes the steps of (a) producing a catalyst containing Fe and Mo supported on MgO powder, (b) using a mixture of hydrogen and carbon containing gas as precursors, and (c) heating the catalyst to a temperature above 950.degree. C. to produce a carbon nanotube. Another method of fabricating an electron field emission cathode includes the steps of (a) synthesizing electron field emission materials containing carbon nanotubes with a number of concentric graphene shells per tube from two to ten, an outer diameter of from 2 to 8 nm, and a length greater than 0.1 microns, (b) dispersing the electron field emission material in a suitable solvent, (c) depositing the electron field emission materials onto a substrate, and (d) annealing the substrate.

  18. Feeling music: integration of auditory and tactile inputs in musical meter perception.

    Science.gov (United States)

    Huang, Juan; Gamble, Darik; Sarnlertsophon, Kristine; Wang, Xiaoqin; Hsiao, Steven

    2012-01-01

    Musicians often say that they not only hear, but also "feel" music. To explore the contribution of tactile information in "feeling" musical rhythm, we investigated the degree that auditory and tactile inputs are integrated in humans performing a musical meter recognition task. Subjects discriminated between two types of sequences, 'duple' (march-like rhythms) and 'triple' (waltz-like rhythms) presented in three conditions: 1) Unimodal inputs (auditory or tactile alone), 2) Various combinations of bimodal inputs, where sequences were distributed between the auditory and tactile channels such that a single channel did not produce coherent meter percepts, and 3) Simultaneously presented bimodal inputs where the two channels contained congruent or incongruent meter cues. We first show that meter is perceived similarly well (70%-85%) when tactile or auditory cues are presented alone. We next show in the bimodal experiments that auditory and tactile cues are integrated to produce coherent meter percepts. Performance is high (70%-90%) when all of the metrically important notes are assigned to one channel and is reduced to 60% when half of these notes are assigned to one channel. When the important notes are presented simultaneously to both channels, congruent cues enhance meter recognition (90%). Performance drops dramatically when subjects were presented with incongruent auditory cues (10%), as opposed to incongruent tactile cues (60%), demonstrating that auditory input dominates meter perception. We believe that these results are the first demonstration of cross-modal sensory grouping between any two senses.

  19. Smart meter status report from Toronto

    International Nuclear Information System (INIS)

    O'Brien, D.

    2006-01-01

    An update of Toronto Hydro's smart metering program was presented. Electricity demand is expected to keep increasing, and there is presently insufficient generation to match supply needs in Ontario. The smart metering program was introduced to aid in the Ontario government's energy conservation strategy, as well as to address peak supply problems that have led to power outages. It is expected that the smart metering program will reduce provincial peak supply by 5 per cent, as the meters support both time-of-use rates and critical peak pricing. Over 800,000 smart meters will be supplied to customers by 2007, and all 4.3 million homes in Toronto will have a smart meter by 2010. In order to meet targets for 2010, the utility will continue to install more 15,000 meters each month for the next 4 years. While the Ontario government has planned and coordinated the rollout and developed smart metering specifications and standards, Toronto Hydro is responsible for the purchase, installation, operation and maintenance of the meters. Advance testing of each meter is needed to ensure billing accuracy, and customer education on meter use is also. The complexity of the metering program has led the utility to establish a rigid project management process. Customer education pilot program are currently being conducted. Experience gained during the earlier phases of the program have enabled the utility to select appropriate metering systems based on density, topography and physical conditions. Project expenditures have been within budget due to improved project estimating and planning. The metering program has been conducted in tandem with the utility's peakSAVER program, a residential and small commercial load control program that has been successful in reducing summer peak demand by cycling air conditioners without causing discomfort. It was concluded that the utility will continue with its mass deployment of smart meters, and is currently preparing its call center to handled

  20. Streamlining Smart Meter Data Analytics

    OpenAIRE

    Liu, Xiufeng; Nielsen, Per Sieverts

    2015-01-01

    Today smart meters are increasingly used in worldwide. Smart meters are the advanced meters capable of measuring customer energy consumption at a fine-grained time interval, e.g., every 15 minutes. The data are very sizable, and might be from different sources, along with the other social-economic metrics such as the geographic information of meters, the information about users and their property, geographic location and others, which make the data management very complex. On the other hand, ...

  1. Infants prefer the musical meter of their own culture: a cross-cultural comparison.

    Science.gov (United States)

    Soley, Gaye; Hannon, Erin E

    2010-01-01

    Infants prefer native structures such as familiar faces and languages. Music is a universal human activity containing structures that vary cross-culturally. For example, Western music has temporally regular metric structures, whereas music of the Balkans (e.g., Bulgaria, Macedonia, Turkey) can have both regular and irregular structures. We presented 4- to 8-month-old American and Turkish infants with contrasting melodies to determine whether cultural background would influence their preferences for musical meter. In Experiment 1, American infants preferred Western over Balkan meter, whereas Turkish infants, who were familiar with both Western and Balkan meters, exhibited no preference. Experiments 2 and 3 presented infants with either a Western or Balkan meter paired with an arbitrary rhythm with complex ratios not common to any musical culture. Both Turkish and American infants preferred Western and Balkan meter to an arbitrary meter. Infants' musical preferences appear to be driven by culture-specific experience and a culture-general preference for simplicity. Copyright 2009 APA, all rights reserved.

  2. Helium Adsorption on Carbon Nanotube Bundles with Different Diameters:. Molecular Dynamics Simulation

    Science.gov (United States)

    Majidi, R.; Karami, A. R.

    2013-05-01

    We have used molecular dynamics simulation to study helium adsorption capacity of carbon nanotube bundles with different diameters. Homogeneous carbon nanotube bundles of (8,8), (9,9), (10,10), (11,11), and (12,12) single walled carbon nanotubes have been considered. The results indicate that the exohedral adsorption coverage does not depend on the diameter of carbon nanotubes, while the endohedral adsorption coverage is increased by increasing the diameter.

  3. Inversion of Orkney M5.5 earthquake South Africa using strain meters at very close distances

    Science.gov (United States)

    Yasutomi, T.; Mori, J. J.; Yamada, M.; Ogasawara, H.; Okubo, M.; Ogasawara, H.; Ishida, A.

    2017-12-01

    The largest event recorded in a South African gold mining region, a M5.5 earthquake took place near Orkney on 5 August 2014. The mainshock and afterhocks were recorded by 46 geophones at 2-3 km depths, 3 Ishii borehole strainmeters at 2.9km depth, and 17 surface strong motion instruments at close distances. The upper edge of the planar distribution of aftershock activity dips almost vertically and was only several hundred meters below the sites where the strainmeters were installed. In addition the seismic data, drilling across this fault is now in progress (Jun 2017 to December 2017) and will contribute valuable geological and stress information. Although the geophones data were saturated during the mainshock, the strainmeters recorded clear nearfield waveforms. We try to model the source of the M5.5 mainshock using the nearfield strainmeter data. Two strain meters located at same place, depth at 2.8km. Remaining one is located depth at 2.9km. Distance of each other is only 150m. Located at depth 2.9km recorded large stable strain, on the other hand, located at depth 2.8 km recorded three or four times smaller stable strain than 2.9km. These data indicates the distance between M5.5 fault and 2.9km depth strainmeter is a few hundred meters order. The strain Green functions were calculated assuming an infinite medium and using a finite difference method. We use small aftershocks to verify the Green function. Matching of the waveforms for the small events validates and Green functions used for the mainshock inversion. We present a model of the source rupture using these strain data. The nearfield data provide good resolution of the nearby earthquake rupture. There are two large subevents, one near the hypocenter and the second several hundred meters to the west.

  4. Technique of Hurdle Clearing in 400 Meters Hurdles (Study Review)

    OpenAIRE

    Jakoubek, Jiří

    2017-01-01

    Title: Technique of Hurdle Clearing in 400 Meters Hurdles (Study Review) Authors: Jiří Jakoubek Supervisor: PhDr. Aleš Kaplan, Ph.D. Aims: The aim of this thesis is to describe technique of hurdle clearing in 400 meters hurdle race using study review and to examine this technique at particular athlete during training and racing sessions in 400 meters hurdles race. Methods: Technique was compared and examined at young athlete. Two kinograms were used for analysis, one from training and one fro...

  5. Calibration of reference KAP-meters at SSDL and cross calibration of clinical KAP-meters

    International Nuclear Information System (INIS)

    Hetland, Per O.; Friberg, Eva G.; Oevreboe, Kirsti M.; Bjerke, Hans H.

    2009-01-01

    In the summer of 2007 the secondary standard dosimetry laboratory (SSDL) in Norway established a calibration service for reference air-kerma product meter (KAP-meter). The air-kerma area product, PKA, is a dosimetric quantity that can be directly related to the patient dose and used for risk assessment associated with different x-ray examinations. The calibration of reference KAP-meters at the SSDL gives important information on parameters influencing the calibration factor for different types of KAP-meters. The use of reference KAP-meters calibrated at the SSDL is an easy and reliable way to calibrate or verify the PKA indicated by the x-ray equipment out in the clinics. Material and methods. Twelve KAP-meters were calibrated at the SSDL by use of the substitution method at five diagnostic radiation qualities (RQRs). Results. The calibration factors varied from 0.94 to 1.18. The energy response of the individual KAP-meters varied by a total of 20% between the different RQRs and the typical chamber transmission factors ranged from 0.78 to 0.91. Discussion. It is important to use a calibrated reference KAP-meter and a harmonised calibration method in the PKA calibration in hospitals. The obtained uncertainty in the PKA readings is comparable with other calibration methods if the information in the calibration certificate is correct used, corrections are made and proper positioning of the KAP-chamber is performed. This will ensure a reliable estimate of the patient dose and a proper optimisation of conventional x-ray examinations and interventional procedures

  6. Solid state semiconductor detectorized survey meter

    International Nuclear Information System (INIS)

    Okamoto, Eisuke; Nagase, Yoshiyuki; Furuhashi, Masato

    1987-01-01

    Survey meters are used for measurement of gamma ray dose rate of the space and the surface contamination dencity that the atomic energy plant and the radiation facility etc. We have recently developed semiconductor type survey meter (Commercial name: Compact Survey Meter). This survey meter is a small-sized dose rate meter with excellent function. The special features are using semiconductor type detector which we have developed by our own technique, stablar wide range than the old type, long life, and easy to carry. Now we introduce the efficiency and the function of the survey meter. (author)

  7. Interfacial structures in downward two-phase bubbly flow

    International Nuclear Information System (INIS)

    Paranjape, S.S.; Kim, S.; Ishii, M.; Kelly, J.

    2003-01-01

    Downward two-phase flow was studied considering its significance in view of Light Water Reactor Accidents (LWR) such as Loss of Heat Sink (LOHS) by feed water loss or secondary pipe break. The flow studied, was an adiabatic, air-water, co-current, vertically downward two-phase flow. The experimental test sections had internal hydraulic diameters of 25.4 mm and 50.8 mm. Flow regime map was obtained using the characteristic signals obtained from an impedance void meter, employing neural network based identification methodology to minimize the subjective judgment in determining the flow regimes. A four sensor conductivity probe was used to measure the local two phase flow parameters, which characterize the interfacial structures. The local time averaged two-phase flow parameters measured were: void fraction (α), interfacial area concentration (a i ), bubble velocity (v g ), and Sauter mean diameter (D Sm ). The flow conditions were from the bubbly flow regime. The local profiles of these parameters as well as their axial development revealed the nature of the interfacial structures and the bubble interaction mechanisms occurring in the flow. Furthermore, this study provided a good database for the development of the interfacial area transport equation, which dynamically models the changes in the interfacial area along the flow field. An interfacial area transport equation was developed for downward flow based on that developed for the upward flow, with certain modifications in the bubble interaction terms. The area averaged values of the interfacial area concentration were compared with those predicted by the interfacial area transport model. (author)

  8. Gamma ray scanning as troubleshooting tool for unusual and large diameter refinery vacuum columns

    International Nuclear Information System (INIS)

    Sarkar, T.K.; Chawla, R.; Banik, S.; Chopra, S.J.; Singh, G.; Pant, H.J.; Sreeramakrishnan, P.; Dhar, D.C.; Pushpangathan, P.N.; Sharma, V.K.

    1997-01-01

    Gamma scanning of trayed and packed columns is widely used to obtain density profiles and identify on-line problems such as: damaged tray or packing, foaming, flooding, maldistribution, weeping and entrainment, etc. However, scanning of large diameter tray or packed columns requires expertise in handling high intensity gamma sources along with thorough understanding of distillation engineering. Engineers India Limited and the Bhabha Atomic Research Centre undertook scanning of two such large diameter (8.4 m and 7.4 m) trayed and packed refinery vacuum distillation columns and successfully diagnosed the problems and suggested remedial actions. Radiography testing of small diameter columns can be used to confirm gamma scanning results. One such example for ammonia separator column is given

  9. Simple meters get smart? Cost benefit analysis of smart metering infrastructure

    International Nuclear Information System (INIS)

    Van Gerwen, R.J.F.; Jaarsma, S.A.; Koenis, F.T.C.

    2005-08-01

    The Dutch Ministry of Economic Affairs requested a cost-benefit analysis of the large scale introduction of a smart meter infrastructure for gas and electricity consumption by small consumers. The questions asked in the study need to be answered in order to enable a well-founded evaluation of the implementation of smart meters. [mk] [nl

  10. Metering apparatus and tariffs for electricity supply

    International Nuclear Information System (INIS)

    1990-01-01

    Conference papers presented cover system economies and tariff structure with papers on pricing of electricity and new metering technologies. Other topics reviewed include metering apparatus design, electronic metering apparatus and solid phase metering technology. Meter data retrieval, bulk supply metering, test equipment and maintenance, and legal requirements and standards are discussed. (author)

  11. Cross-cultural differences in meter perception.

    Science.gov (United States)

    Kalender, Beste; Trehub, Sandra E; Schellenberg, E Glenn

    2013-03-01

    We examined the influence of incidental exposure to varied metrical patterns from different musical cultures on the perception of complex metrical structures from an unfamiliar musical culture. Adults who were familiar with Western music only (i.e., simple meters) and those who also had limited familiarity with non-Western music were tested on their perception of metrical organization in unfamiliar (Turkish) music with simple and complex meters. Adults who were familiar with Western music detected meter-violating changes in Turkish music with simple meter but not in Turkish music with complex meter. Adults with some exposure to non-Western music that was unmetered or metrically complex detected meter-violating changes in Turkish music with both simple and complex meters, but they performed better on patterns with a simple meter. The implication is that familiarity with varied metrical structures, including those with a non-isochronous tactus, enhances sensitivity to the metrical organization of unfamiliar music.

  12. Multitasking metering enhances generation, transmission operations

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, E.

    2008-11-15

    The Dairyland Power Cooperative (DPC) which operates from La Crosse, Wisconsin has the capacity to generate and transmit 1000 MW of power to 25 member cooperatives and 20 municipalities who serve over 500,000 customers. When DPC was experiencing diminished service within its analog cellular-based data communications system, it was presented with an opportunity to install a new automated telecommunications system that would provide secure collection of meter readings from all of its substations. DPC decided to evaluate an advanced multifunctional digital meter from Schweitzer Engineering Laboratories (SEL). The SEL-734 Revenue Metering System offers complete instantaneous metering functions, including voltages, currents, power, energy and power factor. Other capabilities include predictive demand, time-of-use metering, automatic voltage monitoring, harmonics metering and synchrophasor measurement. From a metering perspective, DPC wanted to perform daily load profiles and interval-by-interval metering of their delivery points for billing purposes. They also wanted to provide real-time monitoring of electricity being delivered for both generation and transmission purposes and to make that information available to a distribution SCADA system for their members. The SEL-734 Revenue Meter was well suited to those needs. The SEL-734 provides very high-accuracy energy metering, load profile data collection, instantaneous power measurements, power quality monitoring, and communicates simultaneously over a modem, serial ports, and wide area networks (WAN). The meter is backed with a ten-year warranty as well as field support engineers. 5 figs.

  13. Smart meter incorporating UWB technology

    NARCIS (Netherlands)

    Khan, T.A.; Khan, A.B.; Babar, M.; Taj, T.A.

    2014-01-01

    Smart Meter is a key element in the evolving concept of Smart Grid, which plays an important role in interaction between the consumer and the supplier. In general, the smart meter is an intelligent digital energy meter that measures the consumption of electrical energy and provides other additional

  14. Good standards for smart meters

    NARCIS (Netherlands)

    Hoenkamp, R.A.; Huitema, G.B.

    2012-01-01

    This paper examines what lessons can be learned from the rollout of smart meters in the Netherlands to improve the European smart meter standardization. This study is based on the case of the Dutch meter rollout which preparations started in 2005 but finally was delayed until 2011 by governmental

  15. RFID-BASED Prepaid Power Meter

    OpenAIRE

    Teymourzadeh, Rozita

    2013-01-01

    An Electric power meter is an important component in electric energy service. In the past, many consumers have complained about reading inaccurate of the electric meter. This research presents the development of an electrical power meter equipped with RFID reader. The RFID reader reads a valid RFID card and activates the power meter so that it can supply electricity. When the credit is about low or before the electricity is auto cut off, an SMS message will be sent to the user’s handphone to ...

  16. Development and applications of new type isotope level-meters for cement factories

    International Nuclear Information System (INIS)

    Yang Shiqing; Min Hainian; Zhang Zhaoqing; Fu Heping; Dang Congjun; Wang Jingmin; Xia Junming

    1998-01-01

    According to the situation of current domestic switch isotope level-meters used for the level measurement and control in cement factories, a new type isotope level-meter is developed. The level-meter includes digit display circuit, count detection and control circuit and two ways control export, its response time is less than 1 second. The quenching circuit in the detector lengthens the using lifespan of G-M counter. The application in the factories indicates that the level-meter has the advantages of sensitive, strong anti-disturbance, reliable and adjustment simplicity. The use of the level-meter can make the better economy benefit and society benefit

  17. Modelling and calibration of a ring-shaped electrostatic meter

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Jianyong [University of Teesside, Middlesbrough TS1 3BA (United Kingdom); Zhou Bin; Xu Chuanlong; Wang Shimin, E-mail: zhoubinde1980@gmail.co [Southeast University, Sipailou 2, Nanjing 210096 (China)

    2009-02-01

    Ring-shaped electrostatic flow meters can provide very useful information on pneumatically transported air-solids mixture. This type of meters are popular in measuring and controlling the pulverized coal flow distribution among conveyors leading to burners in coal-fired power stations, and they have also been used for research purposes, e.g. for the investigation of electrification mechanism of air-solids two-phase flow. In this paper, finite element method (FEM) is employed to analyze the characteristics of ring-shaped electrostatic meters, and a mathematic model has been developed to express the relationship between the meter's voltage output and the motion of charged particles in the sensing volume. The theoretical analysis and the test results using a belt rig demonstrate that the output of the meter depends upon many parameters including the characteristics of conditioning circuitry, the particle velocity vector, the amount and the rate of change of the charge carried by particles, the locations of particles and etc. This paper also introduces a method to optimize the theoretical model via calibration.

  18. Privacy friendly aggregation of smart meter readings, even when meters crash

    NARCIS (Netherlands)

    Hoepman, J.H.

    2017-01-01

    A well studied privacy problem in the area of smart grids is the question of how to aggregate the sum of a set of smart meter readings in a privacy friendly manner, i.e., in such a way that individual meter readings are not revealed to the adversary. Much less well studied is how to deal with

  19. Ramp Metering Influence on Freeway Operational Safety near On-ramp Exits

    Directory of Open Access Journals (Sweden)

    Chiu Liu, PhD, PE, PTOE

    2013-06-01

    Full Text Available Ramp metering has been widely installed in urban areas where congestion on a freeway or an expressway may occur recurrently during weekday peak periods to enhance mainline throughput and reduce system-wide delay. These operational benefits may also help reduce vehicular emissions and improve air quality in urban areas. However, the impact on traffic safety due to ramp metering hasn't been explored in details before. Supported by physical understanding and arguments, we characterize the ramp metering influence on freeway safety by examining vehicular collisions near on-ramp exits within the ramp meter operating hours before and after the activation of the ramp metering. Collisions for a sample of 19 operating ramp meters along several freeways in northern California were collected and organized to show that ramp metering can help reduce freeway collisions at the vicinity of on-ramp exits. It was found that the average reductions on freeway collisions in the vicinity of an on-ramp exit are around 36%. Although most of the reduced collisions belong to the property damage only category, a 36% reduction shows the significant safety benefit of ramp metering. The traffic congestion induced by each collision, especially during peak hours when ramp metering is in operation, could last for an hour or two. Consequently, ramp metering must be contributing to the reduction of non-recurrent congestion in addition to mitigating recurrent congestion, which is better documented. This study strongly supports the implementation of ramp metering in California.

  20. Digital reactivity meter

    International Nuclear Information System (INIS)

    Jiang Zongbing

    1996-02-01

    The importance and the usual methods of reactivity measurement in a nuclear reactor are presented. Emphasis is put upon the calculation principle, software and hardware components, main specifications, application, as well as the features of the digital reactivity meter. The test results of operation in various reactors shown that the meter possess the following features: high accuracy, short response time, low output noise, high resolution, wide measuring range, simple and flexible to operate, high stability and reliability. In addition, the reactivity meter can save the measuring data automatically and have a perfect capability of self-verifying. It not only meet the requirement of the reactivity measurement in nuclear power plant, but also can be applied to various types of reactors. (1 tab.)

  1. Evaluation of the apparent losses caused by water meter under-registration in intermittent water supply.

    Science.gov (United States)

    Criminisi, A; Fontanazza, C M; Freni, G; Loggia, G La

    2009-01-01

    Apparent losses are usually caused by water theft, billing errors, or revenue meter under-registration. While the first two causes are directly related to water utility management and may be reduced by improving company procedures, water meter inaccuracies are considered to be the most significant and hardest to quantify. Water meter errors are amplified in networks subjected to water scarcity, where users adopt private storage tanks to cope with the intermittent water supply. The aim of this paper is to analyse the role of two variables influencing the apparent losses: water meter age and the private storage tank effect on meter performance. The study was carried out in Palermo (Italy). The impact of water meter ageing was evaluated in laboratory by testing 180 revenue meters, ranging from 0 to 45 years in age. The effects of the private water tanks were determined via field monitoring of real users and a mathematical model. This study demonstrates that the impact on apparent losses from the meter starting flow rapidly increases with meter age. Private water tanks, usually fed by a float valve, overstate meter under-registration, producing additional apparent losses between 15% and 40% for the users analysed in this study.

  2. Performance Analysis of Secure and Private Billing Protocols for Smart Metering

    Directory of Open Access Journals (Sweden)

    Tom Eccles

    2017-11-01

    Full Text Available Traditional utility metering is to be replaced by smart metering. Smart metering enables fine-grained utility consumption measurements. These fine-grained measurements raise privacy concerns due to the lifestyle information which can be inferred from the precise time at which utilities were consumed. This paper outlines and compares two privacy-respecting time of use billing protocols for smart metering and investigates their performance on a variety of hardware. These protocols protect the privacy of customers by never transmitting the fine-grained utility readings outside of the customer’s home network. One protocol favors complexity on the trusted smart meter hardware while the other uses homomorphic commitments to offload computation to a third device. Both protocols are designed to operate on top of existing cryptographic secure channel protocols in place on smart meters. Proof of concept software implementations of these protocols have been written and their suitability for real world application to low-performance smart meter hardware is discussed. These protocols may also have application to other privacy conscious aggregation systems, such as electronic voting.

  3. Smart metering design and applications

    CERN Document Server

    Weranga, K S K; Chandima, D P

    2013-01-01

    Taking into account the present day trends and the requirements, this Brief focuses on smart metering of electricity for next generation energy efficiency and conservation. The contents include discussions on the smart metering concepts and existing technologies and systems as well as design and implementation of smart metering schemes together with detailed examples.

  4. File list: Pol.Emb.10.AllAg.Mitotic_cycle_8-9 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Emb.10.AllAg.Mitotic_cycle_8-9 dm3 RNA polymerase Embryo Mitotic cycle 8-9 http...://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Pol.Emb.10.AllAg.Mitotic_cycle_8-9.bed ...

  5. File list: Pol.Emb.20.AllAg.Mitotic_cycle_8-9 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Emb.20.AllAg.Mitotic_cycle_8-9 dm3 RNA polymerase Embryo Mitotic cycle 8-9 http...://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Pol.Emb.20.AllAg.Mitotic_cycle_8-9.bed ...

  6. File list: Pol.Emb.50.AllAg.Mitotic_cycle_8-9 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Emb.50.AllAg.Mitotic_cycle_8-9 dm3 RNA polymerase Embryo Mitotic cycle 8-9 http...://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Pol.Emb.50.AllAg.Mitotic_cycle_8-9.bed ...

  7. Normal cardiac diameters in cine-MRI of the heart

    International Nuclear Information System (INIS)

    Hergan, K.; Schuster, A.; Mair, M.; Burger, R.; Toepker, M.

    2004-01-01

    Purpose: To measure the normal diameters of cardiac cavities in standard cardiac views using cine MRI. Materials and Methods: Fifty-six volunteers were examined (27 male, 29 female) on a 1.5 T MR unit with ECG-triggered single shot free precision (SSFP) cine MR sequences and parallel image acquisition. Standardized echocardiographic planes were used to depict the heart of all volunteers (short axis, 4-chamber view, left and right 2-chamber views). The different diameters of the cardiac cavities were measured using a fixed protocol. Results: For the estimation of ventricular dilatation, the important female/male cross diameters of the left ventricle are 45.2±3.4/51.6±4.6 mm diastolic and 30.5±3.5/33.8±3.6 mm systolic, and of the right ventricle 30.7±3.8/37.1±5.9 mm diastolic and 22.3±3.8/28.1±4.4 mm systolic. For the determination of a left ventricular hypertrophy, relevant septal wall thickness measured in the short axis of the left ventricle of female/male volunteers are 8.0±1.0/9.9±1.2 mm diastolic and 10.9±1.4/13.6±1.9 mm systolic. The measured normal values of male volunteers were generally higher than those of female volunteers. The thickness of the ventricular septum correlated well when measured in the short axis and 4-chamber view. When measured in the 4-chamber view, the longitudinal diameter of the ventricles had a higher value in diastole and a lower value in systole, compared to the 2-chamber views of the right and left cardiac cavities. The atrial longitudinal diameters were higher in the 4-chamber view compared to the 2-chamber views, without any difference in systole or diastole. Conclusion: Diameters of cardiac cavities are easily and quickly measured. Using the tables with the normal values published here, it is simple to estimate an abnormal size of the heart. (orig.)

  8. Primary flow meter for calibrating a sniffer test leak artefact by a pressure rise method

    Science.gov (United States)

    Arai, Kenta; Yoshida, Hajime

    2014-10-01

    Sniffer tests are used to locate leaks in equipment during operation. The sensitivity of a sniffer leak detector must be calibrated against a known gas flow to atmospheric pressure generated by a sniffer test leak artefact. We have developed a primary flow meter for calibrating gas flows to atmospheric pressure through the leak artefact. The flow meter is based on a pressure rise method and two chambers are used to measure the pressure rise with small uncertainty even at atmospheric pressure. The calibration range of the flow rate is 5 × 10-7 Pa m3 s-1 to 7 × 10-4 Pa m3 s-1 to atmospheric pressure at 23.0 °C with a minimum uncertainty of 1.4% (k = 2), as well as 4 × 10-8 Pa m3 s-1 to 5 × 10-4 Pa m3 s-1 to a vacuum at 23.0 °C. The long term stability of the flow meter was determined as 0.41% by repeated measurements of the conductance of the leak artefact. In case of the flow rate into a vacuum, the flow meter was successfully linked to the international reference value of CCM.P-K12 by a lab-internal comparison.

  9. Appendiceal diameter: CT versus sonographic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Orscheln, Emily S. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati, OH (United States); Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-03-15

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  10. Appendiceal diameter: CT versus sonographic measurements

    International Nuclear Information System (INIS)

    Orscheln, Emily S.; Trout, Andrew T.

    2016-01-01

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  11. An Improved Weise’s Rule for Efficient Estimation of Stand Quadratic Mean Diameter

    Directory of Open Access Journals (Sweden)

    Róbert Sedmák

    2015-07-01

    Full Text Available The main objective of this study was to explore the accuracy of Weise’s rule of thumb applied to an estimation of the quadratic mean diameter of a forest stand. Virtual stands of European beech (Fagus sylvatica L. across a range of structure types were stochastically generated and random sampling was simulated. We compared the bias and accuracy of stand quadratic mean diameter estimates, employing different ranks of measured stems from a set of the 10 trees nearest to the sampling point. We proposed several modifications of the original Weise’s rule based on the measurement and averaging of two different ranks centered to a target rank. In accordance with the original formulation of the empirical rule, we recommend the application of the measurement of the 6th stem in rank corresponding to the 55% sample percentile of diameter distribution, irrespective of mean diameter size and degree of diameter dispersion. The study also revealed that the application of appropriate two-measurement modifications of Weise’s method, the 4th and 8th ranks or 3rd and 9th ranks averaged to the 6th central rank, should be preferred over the classic one-measurement estimation. The modified versions are characterised by an improved accuracy (about 25% without statistically significant bias and measurement costs comparable to the classic Weise method.

  12. New Hybrid Algorithms for Estimating Tree Stem Diameters at Breast Height Using a Two Dimensional Terrestrial Laser Scanner

    Directory of Open Access Journals (Sweden)

    Jianlei Kong

    2015-07-01

    Full Text Available In this paper, a new algorithm to improve the accuracy of estimating diameter at breast height (DBH for tree trunks in forest areas is proposed. First, the information is collected by a two-dimensional terrestrial laser scanner (2DTLS, which emits laser pulses to generate a point cloud. After extraction and filtration, the laser point clusters of the trunks are obtained, which are optimized by an arithmetic means method. Then, an algebraic circle fitting algorithm in polar form is non-linearly optimized by the Levenberg-Marquardt method to form a new hybrid algorithm, which is used to acquire the diameters and positions of the trees. Compared with previous works, this proposed method improves the accuracy of diameter estimation of trees significantly and effectively reduces the calculation time. Moreover, the experimental results indicate that this method is stable and suitable for the most challenging conditions, which has practical significance in improving the operating efficiency of forest harvester and reducing the risk of causing accidents.

  13. FIELD-PRODUCED JP-8 STANDARD FOR CALIBRATION OF LOWER EXPLOSIVE LIMIT METERS USED BY JET FUEL TANK MAINTENANCE PERSONNEL

    Science.gov (United States)

    Thousands of military personnel and tens of thousands of civilian workers perform jet fuel tank entry procedures. Before entering the confined space of a jet fuel tank, OSHA regulations (29CFR1910.146) require the internal atmosphere be tested with a calibrated, direct-reading...

  14. Streamlining Smart Meter Data Analytics

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2015-01-01

    of the so-called big data possible. This can improve energy management, e.g., help utilities improve the management of energy and services, and help customers save money. As this regard, the paper focuses on building an innovative software solution to streamline smart meter data analytic, aiming at dealing......Today smart meters are increasingly used in worldwide. Smart meters are the advanced meters capable of measuring customer energy consumption at a fine-grained time interval, e.g., every 15 minutes. The data are very sizable, and might be from different sources, along with the other social......-economic metrics such as the geographic information of meters, the information about users and their property, geographic location and others, which make the data management very complex. On the other hand, data-mining and the emerging cloud computing technologies make the collection, management, and analysis...

  15. File list: ALL.Emb.05.AllAg.Mitotic_cycle_8-9 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Emb.05.AllAg.Mitotic_cycle_8-9 dm3 All antigens Embryo Mitotic cycle 8-9 SRX084...383 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Emb.05.AllAg.Mitotic_cycle_8-9.bed ...

  16. File list: ALL.Emb.20.AllAg.Mitotic_cycle_8-9 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Emb.20.AllAg.Mitotic_cycle_8-9 dm3 All antigens Embryo Mitotic cycle 8-9 SRX084...383 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Emb.20.AllAg.Mitotic_cycle_8-9.bed ...

  17. Measurement error in CT assessment of appendix diameter

    Energy Technology Data Exchange (ETDEWEB)

    Trout, Andrew T.; Towbin, Alexander J. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, MLC 5031, Cincinnati, OH (United States); Zhang, Bin [Cincinnati Children' s Hospital Medical Center, Department of Biostatistics and Epidemiology, Cincinnati, OH (United States)

    2016-12-15

    Appendiceal diameter continues to be cited as an important criterion for diagnosis of appendicitis by computed tomography (CT). To assess sources of error and variability in appendiceal diameter measurements by CT. In this institutional review board-approved review of imaging and medical records, we reviewed CTs performed in children <18 years of age between Jan. 1 and Dec. 31, 2010. Appendiceal diameter was measured in the axial and coronal planes by two reviewers (R1, R2). One year later, 10% of cases were remeasured. For patients who had multiple CTs, serial measurements were made to assess within patient variability. Measurement differences between planes, within and between reviewers, within patients and between CT and pathological measurements were assessed using correlation coefficients and paired t-tests. Six hundred thirty-one CTs performed in 519 patients (mean age: 10.9 ± 4.9 years, 50.8% female) were reviewed. Axial and coronal measurements were strongly correlated (r = 0.92-0.94, P < 0.0001) with coronal plane measurements significantly larger (P < 0.0001). Measurements were strongly correlated between reviewers (r = 0.89-0.9, P < 0.0001) but differed significantly in both planes (axial: +0.2 mm, P=0.003; coronal: +0.1 mm, P=0.007). Repeat measurements were significantly different for one reviewer only in the axial plane (0.3 mm difference, P<0.05). Within patients imaged multiple times, measured appendix diameters differed significantly in the axial plane for both reviewers (R1: 0.5 mm, P = 0.031; R2: 0.7 mm, P = 0.022). Multiple potential sources of measurement error raise concern about the use of rigid diameter cutoffs for the diagnosis of acute appendicitis by CT. (orig.)

  18. Diameter Effect of Silver Nanorod Arrays to Surface-enhanced Raman Scattering

    International Nuclear Information System (INIS)

    Gu, Geun Hoi; Kim, Min Young; Yoon, Hyeok Jin; Suh, Jung Sang

    2014-01-01

    The effect the diameter of silver nanorod arrays whose distance between the nanorods was uniform at 65 nm have on Surface-enhanced Raman Scattering (SERS) has been studied by varying the diameter from 28 to 51 nm. Nanorod length was fixed at approximately 62 nm, which is the optimum length for SERS by excitation with a 632.8 nm laser line. The transverse and longitudinal modes of the surface plasmon of these silver nanorods were near 400 and 630 nm, respectively. The extinction of the longitudinal mode increased with increasing nanorod diameter, while the transverse mode did not change significantly. High-quality SERS spectra of p-aminothiophenol and benzenethiol adsorbed on the tips of the silver nanorods were observed by excitation with a 632.8 nm laser line. The SERS enhancement increased with increasing nanorod diameter. We concluded that the SERS enhancement increases when the diameter of silver nanorods is increased mainly by increasing the excitation efficiency of the longitudinal mode. The enhancement factor for the silver nanorods with a 51 nm diameter was approximately 2 Χ 10 7

  19. Net metering: zero electricity bill

    International Nuclear Information System (INIS)

    Mangi, A.; Khan, Z.

    2011-01-01

    Worldwide move towards renewable energy sources, environmental concerns and decentralization of the power sector have made net metering an attractive option for power generation at small scale. This paper discusses the net metering, economical issues of renewable sources in Pakistan, technical aspects, installation suitability according to varying terrain, existing utility rules and formulation of legislation for net metering making it economically attractive. (author)

  20. Ontology - MicrobeDB.jp | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available gzip) consists of some directories (see the following table). Data file File name: ontology....tar.gz File URL: ftp://ftp.biosciencedbc.jp/archive/microbedb/LATEST/ontology.tar.gz File size: 9...he NCBI Taxonomy and INSDC ontology files were obtained from the DDBJ web site. O...ples Data item Description ontology/meo/meo.ttl An ontology for describing organismal habitats (especially focused on microbes). onto...logy/meo/meo_fma_mapping.ttl An ontology mapping files t

  1. Electro-optical equivalent calibration technology for high-energy laser energy meters

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Ji Feng, E-mail: wjfcom2000@163.com [State Key Laboratory of Precision Measurement Technology and Instrument, Tsinghua University, Beijing 100084 (China); Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China); Graduate School of China Academy of Engineering Physics, Beijing 100088 (China); Key Laboratory of Laser Science and Technology, China Academy of Engineering Physics, Mianyang 621900 (China); Chang, Yan; Zhang, Kai; Hu, Xiao Yang; Zhang, Wei [Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China); Key Laboratory of Laser Science and Technology, China Academy of Engineering Physics, Mianyang 621900 (China); Sun, Li Qun [State Key Laboratory of Precision Measurement Technology and Instrument, Tsinghua University, Beijing 100084 (China)

    2016-04-15

    Electro-optical equivalent calibration with high calibration power and high equivalence is particularly well-suited to the calibration of high-energy laser energy meters. A large amount of energy is reserved during this process, however, which continues to radiate after power-off. This study measured the radiation efficiency of a halogen tungsten lamp during power-on and after power-off in order to calculate the total energy irradiated by a lamp until the high-energy laser energy meter reaches thermal equilibrium. A calibration system was designed based on the measurement results, and the calibration equivalence of the system was analyzed in detail. Results show that measurement precision is significantly affected by the absorption factor of the absorption chamber and by heat loss in the energy meter. Calibration precision is successfully improved by enhancing the equivalent power and reducing power-on time. The electro-optical equivalent calibration system, measurement uncertainty of which was evaluated as 2.4% (k = 2), was used to calibrate a graphite-cone-absorption-cavity absolute energy meter, yielding a calibration coefficient of 1.009 and measurement uncertainty of 3.5% (k = 2). A water-absorption-type high-energy laser energy meter with measurement uncertainty of 4.8% (k = 2) was considered the reference standard, and compared to the energy meter calibrated in this study, yielded a correction factor of 0.995 (standard deviation of 1.4%).

  2. How to use your peak flow meter

    Science.gov (United States)

    ... meter - how to use; Asthma - peak flow meter; Reactive airway disease - peak flow meter; Bronchial asthma - peak ... 2014:chap 55. National Asthma Education and Prevention Program website. How to use a peak flow meter. ...

  3. File list: Oth.Emb.10.AllAg.Mitotic_cycle_8-9 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Emb.10.AllAg.Mitotic_cycle_8-9 dm3 TFs and others Embryo Mitotic cycle 8-9 SRX0...84383 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.Emb.10.AllAg.Mitotic_cycle_8-9.bed ...

  4. File list: ALL.Emb.10.AllAg.4-8h_embryos [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Emb.10.AllAg.4-8h_embryos dm3 All antigens Embryo 4-8h embryos SRX013021,SRX013...13022 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Emb.10.AllAg.4-8h_embryos.bed ...

  5. File list: Unc.Emb.05.AllAg.8-12h_embryos [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Emb.05.AllAg.8-12h_embryos dm3 Unclassified Embryo 8-12h embryos SRX013080,SRX0...13116 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Unc.Emb.05.AllAg.8-12h_embryos.bed ...

  6. Monitoring the Inhalation Flow Rate of Nebulized Aerosols Using an Ultrasonic Flow Meter: In Vitro Assessment.

    Science.gov (United States)

    Yang, Michael Y; Chan, Hak-Kim

    2017-06-01

    The measurement of aerosol flow rates without obscuration of the flow is of particular concern with in vivo lung deposition studies, where precise knowledge of aerosol particle size distributions is a necessary requirement for the development of predictive correlations. This study examines the utility of an ultrasonic flow meter for such measurements and determines if a valved system can be attached to the flow meter for sampling exhaled aerosols. The flow rate across a D-30 flow meter was compared with and without nebulization of 0.9% saline aerosols from a PARI LC Sprint nebulizer. Particle size distributions of the nebulized aerosol before and after adding the D-30 flow meter and duckbill valve were measured using a Spraytec laser diffraction system. Finally, the ability of the Thor D-30 to capture a realistic breathing profile was assessed. The mean ± standard error flow rates measured by the D-30 flow meter with and without nebulization were 10.4 ± 0.1 versus 10.4 ± 0.1 L/min, 66.4 ± 0.1 versus 67.2 ± 0.1 L/min, and 89.9 ± 0.1 versus 91.4 ± 0.1 L/min. The D-30 flow meter did not considerably affect the volumetric median diameter (VMD) of the aerosols, while the VMD reduced slightly by 0.65 μm at 10 L/min and 0.69 μm at 72 L/min upon the inclusion of a duckbill valve. Time-weighted average inhalation flow rates measured by D-30 flow meters placed upstream and downstream of the one-way valve agreed well, 31.9 versus 32.6 L/min, respectively. The D-30 flow meter can be used to accurately measure inhalation flow rates of nebulized aerosols without significantly impacting particle size distributions, and one-way duckbill valves can be used to isolate the inhalation portion of a breathing pattern to facilitate collection of exhaled doses.

  7. Conditioning a segmented stem profile model for two diameter measurements

    Science.gov (United States)

    Raymond L. Czaplewski; Joe P. Mcclure

    1988-01-01

    The stem profile model of Max and Burkhart (1976) is conditioned for dbh and a second upper stem measurement. This model was applied to a loblolly pine data set using diameter outside bark at 5.3m (i.e., height of 17.3 foot Girard form class) as the second upper stem measurement, and then compared to the original, unconditioned model. Variance of residuals was reduced...

  8. Community Net Energy Metering: How Novel Policies Expand Benefits of Net Metering to Non-Generators

    Energy Technology Data Exchange (ETDEWEB)

    Rose, James; Varnado, Laurel

    2009-04-01

    As interest in community solutions to renewable energy grows, more states are beginning to develop policies that encourage properties with more than one meter to install shared renewable energy systems. State net metering policies are evolving to allow the aggregation of multiple meters on a customer’s property and to dissolve conventional geographical boundaries. This trend means net metering is expanding out of its traditional function as an enabling incentive to offset onsite customer load at a single facility. This paper analyzes community net energy metering (CNEM) as an emerging vehicle by which farmers, neighborhoods, and municipalities may more easily finance and reap the benefits of renewable energy. Specifically, it aims to compare and contrast the definition of geographical boundaries among different CNEM models and examine the benefits and limitations of each approach. As state policies begin to stretch the geographic boundaries of net metering, they allow inventive solutions to encourage renewable energy investment. This paper attempts to initiate the conversation on this emerging policy mechanism and offers recommendations for further development of these policies.

  9. Sector smart meter audit review report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-03-31

    This paper presented the results of an electricity distributor sector smart meter audit review conducted by the Ontario Energy Board (OEB) for the period of January 1, 2006 to September 30, 2009. The review summarized the results of a questionnaire related to distributors' smart meter regulatory accounting treatment. Seventy-eight distributors responded to the survey. The review included details of: (1) total investments in smart metering initiative for capital expenditures (CAPEX) and operating maintenance and administrative expenses (OM and A), (2) funding dollars received by the distributors, (3) board-approved recoveries for CAPEX and OM and A, (4) recorded stranded meter costs, and (5) number of smart meters installed in the review period. The audit review demonstrated that some distributors incorrectly recorded carrying charges related to smart meter OM and A expenses, and that some smart meter transactions were recorded in accounts other than OEB established accounts in the general ledger. Results of the audit will be used to provide further accounting assistance to electricity distributors. 7 tabs.

  10. Hardware Design of a Smart Meter

    OpenAIRE

    Ganiyu A. Ajenikoko; Anthony A. Olaomi

    2014-01-01

    Smart meters are electronic measurement devices used by utilities to communicate information for billing customers and operating their electric systems. This paper presents the hardware design of a smart meter. Sensing and circuit protection circuits are included in the design of the smart meter in which resistors are naturally a fundamental part of the electronic design. Smart meters provides a route for energy savings, real-time pricing, automated data collection and elimina...

  11. Optical cycle power meter

    DEFF Research Database (Denmark)

    2014-01-01

    A bicycle power meter for measuring power generated when riding a bicycle, the power meter comprising a position-sensitive radiation detector (409) attachable to a component of a crank set (404) of bicycle, and a radiation source (408) attachable to the component of the crank set and configured t...

  12. Microevolution and Patterns of Dissemination of the JP2 Clone of Aggregatibacter (Actinobacillus) actinomycetemcomitans

    DEFF Research Database (Denmark)

    Haubek, Dorte; Poulsen, Knud; Kilian, Mogens

    2007-01-01

    belonging to the JP2 clone had a number of point mutations, particularly in the pseudogenes hbpA and tbpA. Characteristic mutations allowed isolates from individuals from the Mediterranean area and from West Africa, including the Cape Verde Islands, to be distinguished. The patterns of mutations indicate...

  13. Comparison of urethral diameters for calculating the urethral dose after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Matsuo, Masayuki; Nakano, Masahiro; Kubota, Yasuaki; Maeda, Sunaho; Ohtakara, Kazuhiro; Deguchi, Takashi; Hoshi, Hiroaki

    2007-01-01

    No studies have yet evaluated the effects of a dosimetric analysis for different urethral volumes. We therefore evaluated the effects of a dosimetric analysis to determine the different urethral volumes. This study was based on computed tomography/magnetic resonance imaging (CT/MRI) combined findings in 30 patients who had undergone prostate brachytherapy. Postimplant CT/MRI scans were performed 30 days after the implant. The urethra was contoured based on its diameter (8, 6, 4, 2, and 0 mm). The total urethral volume-in cubic centimeters [UrV150/200 (cc)] and percent (UrV150%/200%), of the urethra receiving 150% or 200% of the prescribed dose-and the doses (UrD90/30/5) in Grays to 90%, 30%, and 5% of the urethral volume were measured based on the urethral diameters. The UrV150 (cc) and UrD30 were statistically different between the of 8-, 6-, 4-, 2-, and 0-mm diameters, whereas the UrD5 was statistically different only between the 8-, 6-, and 4-mm diameters. Especially for UrD5, there was an approximately 40-Gy difference between the mean values for the 8- and 0-mm diameters. We recommend that the urethra should be contoured as a 4- to 6-mm diameter circle or one side of a triangle of 5-7 mm. By standardizing the urethral diameter, the urethral dose will be less affected by the total urethral volume. (author)

  14. File list: InP.Emb.20.AllAg.Mitotic_cycle_8-9 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Emb.20.AllAg.Mitotic_cycle_8-9 dm3 Input control Embryo Mitotic cycle 8-9 http:...//dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/InP.Emb.20.AllAg.Mitotic_cycle_8-9.bed ...

  15. File list: InP.Emb.50.AllAg.Mitotic_cycle_8-9 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Emb.50.AllAg.Mitotic_cycle_8-9 dm3 Input control Embryo Mitotic cycle 8-9 http:...//dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/InP.Emb.50.AllAg.Mitotic_cycle_8-9.bed ...

  16. Ramp metering with an objective to reduce fuel consumption

    OpenAIRE

    Vreeswijk, Jacob Dirk; Woldeab, Zeremariam; de Koning, Anne; Bie, Jing

    2011-01-01

    Ramp meters successfully decrease congestion but leave a burden on the traffic situation at on-ramps. Chaotic queuing leads to many stop-and-go movements and causes inefficiency where fuel consumption is concerned. As part of the eCoMove project, complementary strategies are being designed and evaluated to reduce fuel consumption at metered on-ramps, using vehicle-to-infrastructure communication. This paper presents the design of two strategies, as well as their effect as derived from simulat...

  17. File list: Oth.Emb.10.AllAg.4-8h_embryos [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Emb.10.AllAg.4-8h_embryos dm3 TFs and others Embryo 4-8h embryos SRX013053,SRX0...16156 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.Emb.10.AllAg.4-8h_embryos.bed ...

  18. Net metering in British Columbia : white paper

    International Nuclear Information System (INIS)

    Berry, T.

    2003-01-01

    Net metering was described as being the reverse registration of an electricity customer's revenue meter when interconnected with a utility's grid. It is a provincial policy designed to encourage small-distributed renewable power generation such as micro-hydro, solar energy, fuel cells, and larger-scale wind energy. It was noted that interconnection standards for small generation is an important issue that must be addressed. The British Columbia Utilities Commission has asked BC Hydro to prepare a report on the merits of net metering in order to support consultations on a potential net metering tariff application by the utility. This report provides information on net metering with reference to experience in other jurisdictions with net metering, and the possible costs and benefits associated with net metering from both a utility and consumer perspective. Some of the barriers and policy considerations for successful implementation of net metering were also discussed. refs., tabs., figs

  19. Lunar Noise-Temperature Increase Measurements at S-Band, X-Band, and Ka-Band Using a 34-Meter-Diameter Beam-Waveguide Antenna

    Science.gov (United States)

    Morabito, D. D.

    2006-08-01

    The Moon radiates energy at infrared and microwave wavelengths, in addition to reflecting sunlight at optical wavelengths. As a result, an antenna pointed at or near the Moon will cause an increase in receiver noise temperature that needs to be accounted for in telemetry, radio science, or ranging link budgets. The Deep Space Network may be required to use its antennas in future lunar robotic or human missions, and thus it is important to understand the nature of this temperature increase as a function of observing frequency, lunar phase, and angular offset of the antenna beam from the center of the lunar disk. This article quantifies such a set of measurements acquired at DSS 13, a 34-m-diameter research and development beam-waveguide antenna located at Goldstone, California, at three different telecommunication frequencies, S-band (2.3 GHz), X-band (8.4 GHz), and Ka-band (32 GHz), over a wide range of lunar phase, for both disk-centered and limb-centered positions of the antenna beam.

  20. Calibration methodology application of kerma area product meters in situ: Preliminary results

    Science.gov (United States)

    Costa, N. A.; Potiens, M. P. A.

    2014-11-01

    The kerma-area product (KAP) is a useful quantity to establish the reference levels of conventional X-ray examinations. It can be obtained by measurements carried out with a KAP meter on a plane parallel transmission ionization chamber mounted on the X-ray system. A KAP meter can be calibrated in laboratory or in situ, where it is used. It is important to use one reference KAP meter in order to obtain reliable quantity of doses on the patient. The Patient Dose Calibrator (PDC) is a new equipment from Radcal that measures KAP. It was manufactured following the IEC 60580 recommendations, an international standard for KAP meters. This study had the aim to calibrate KAP meters using the PDC in situ. Previous studies and the quality control program of the PDC have shown that it has good function in characterization tests of dosimeters with ionization chamber and it also has low energy dependence. Three types of KAP meters were calibrated in four different diagnostic X-ray equipments. The voltages used in the two first calibrations were 50 kV, 70 kV, 100 kV and 120 kV. The other two used 50 kV, 70 kV and 90 kV. This was related to the equipments limitations. The field sizes used for the calibration were 10 cm, 20 cm and 30 cm. The calibrations were done in three different cities with the purpose to analyze the reproducibility of the PDC. The results gave the calibration coefficient for each KAP meter and showed that the PDC can be used as a reference instrument to calibrate clinical KAP meters.

  1. Reverse water-in-fluorocarbon emulsions for use in pressurized metered-dose inhalers containing hydrofluoroalkane propellants.

    Science.gov (United States)

    Butz, N; Porté, C; Courrier, H; Krafft, M P; Vandamme, Th F

    2002-05-15

    Pulmonary administration of drugs has demonstrated numerous advantages in the treatment of pulmonary diseases due to direct targeting to the respiratory tract. It enables avoiding the first pass effect, reduces the amount of drugs administered, targets drugs to specific sites and reduces their side effects. Reverse water-in-fluorocarbon (FC) emulsions are potential drug delivery systems for pulmonary administration using pressurized metered-dose inhalers (pMDI). The external phase of these emulsions consists of perfluorooctyl bromide (PFOB, perflubron), whereas their internal phase contains the drugs solubilized or dispersed in water. These emulsions are stabilized by a perfluoroalkylated dimorpholinophosphate (F8H11DMP), i.e. a fluorinated surfactant. This study demonstrates the possibility of delivering a reverse fluorocarbon emulsion via the pulmonary route using a CFC-free pMDI. Two hydrofluoroalkanes (HFAs) (Solkane(R) 134a and Solkane(R) 227) were used as propellants, and various solution (or emulsion)/propellant ratios (1/3, 1/2, 2/3, 1/1, 3/2, 3/1 v/v) were investigated. The insolubility of water (with or without the fluorinated surfactant F8H11DMP) in both HFA 227 and HFA 134a was demonstrated. PFOB and the reverse emulsion were totally soluble or dispersible in all proportions in both propellants. This study demonstrated also that the reverse FC emulsion can be successfully used to deliver caffeine in a homogeneous and reproducible way. The mean diameter of the emulsion water droplets in the pressured canister was investigated immediately after packaging and after 1 week of storage at room temperature. Best results were obtained with emulsion/propellant ratios comprised between 2/3 and 3/2, and with HFA 227 as propellant.

  2. JP8 Reformation for Combat Vehicles

    Science.gov (United States)

    2007-08-07

    phase (fuel), and a gas phase (hydrogen) at elevated pressures. • Trickle - bed configuration is difficult to model and scale down—not practical for...gases output from HDS reactor are used to fuel the reformer. Current Technology Status: •Integrated desulfurization/reforming system successfully

  3. JP-8 and Other Military Fuels

    Science.gov (United States)

    2011-12-01

    Fermentation Jet Fuel-Like Product sugarcane Alcohol Oligomerization Conventional Refinery ProcessesSugar switchgrass Dehydration Pyrolysis Fermentation...PolymerizationOlefins Lignocellulose corn stover forest waste Jet Fuel-Like ProductBio-CrudePyrolysis Hydroprocessing Unclassified Back Up Slides

  4. Forecasting USAF JP-8 Fuel Needs

    Science.gov (United States)

    2009-03-01

    1924 “Keeping America competitive requires affordable energy. And here we have a serious problem: America is addicted to oil, which is often...imported from unstable parts of world. The best way to break this addiction is through technology.” President George W. Bush, State of the Union Address...10 illuminant. Hence, its use spread in Western Pennsylvania and New York City”, while whale oil was preferred by the wealthy people and caused over

  5. Immunotoxicology of JP-8 Jet Fuel

    National Research Council Canada - National Science Library

    Harris, David

    2000-01-01

    ... of infectious disease and cancer. Chronic exposure to jet fuel has been shown to adversely affect human liver function, to cause emotional dysfunction, to cause abnormal electroencephalograms, to cause shortened attention spans...

  6. File list: Unc.Emb.50.AllAg.8-16h_embryos [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Emb.50.AllAg.8-16h_embryos dm3 Unclassified Embryo 8-16h embryos SRX025491,SRX0...25483,SRX025465,SRX025481 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Unc.Emb.50.AllAg.8-16h_embryos.bed ...

  7. Comparison of two different methods for the uncertainty estimation of circle diameter measurements using an optical coordinate measuring machine

    DEFF Research Database (Denmark)

    Morace, Renata Erica; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2005-01-01

    This paper deals with the uncertainty estimation of measurements performed on optical coordinate measuring machines (CMMs). Two different methods were used to assess the uncertainty of circle diameter measurements using an optical CMM: the sensitivity analysis developing an uncertainty budget...

  8. GOLD - MicrobeDB.jp | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available search(/contents-en/) != -1 || url.search(/index-e.html/) != -1 ) { document.getElementById(lang).innerHTML=.../) != -1 ) { url = url.replace(-e.html,.html); document.getElementById(lang).innerHTML=[ Japanese |...en/,/jp/); document.getElementById(lang).innerHTML=[ Japanese | English ]; } else if ( url.search(//contents...//) != -1 ) { url = url.replace(/contents/,/contents-en/); document.getElementById(lang).innerHTML=[ Japanes...e(/contents-en/,/contents/); document.getElementById(lang).innerHTML=[ Japanese | English ]; } else if( url.

  9. Download - MicrobeDB.jp | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available search(/contents-en/) != -1 || url.search(/index-e.html/) != -1 ) { document.getElementById(lang).innerHTML=.../) != -1 ) { url = url.replace(-e.html,.html); document.getElementById(lang).innerHTML=[ Japanese |...en/,/jp/); document.getElementById(lang).innerHTML=[ Japanese | English ]; } else if ( url.search(//contents...//) != -1 ) { url = url.replace(/contents/,/contents-en/); document.getElementById(lang).innerHTML=[ Japanes...e(/contents-en/,/contents/); document.getElementById(lang).innerHTML=[ Japanese | English ]; } else if( url.

  10. Two Automated Techniques for Carotid Lumen Diameter Measurement: Regional versus Boundary Approaches.

    Science.gov (United States)

    Araki, Tadashi; Kumar, P Krishna; Suri, Harman S; Ikeda, Nobutaka; Gupta, Ajay; Saba, Luca; Rajan, Jeny; Lavra, Francesco; Sharma, Aditya M; Shafique, Shoaib; Nicolaides, Andrew; Laird, John R; Suri, Jasjit S

    2016-07-01

    The degree of stenosis in the carotid artery can be predicted using automated carotid lumen diameter (LD) measured from B-mode ultrasound images. Systolic velocity-based methods for measurement of LD are subjective. With the advancement of high resolution imaging, image-based methods have started to emerge. However, they require robust image analysis for accurate LD measurement. This paper presents two different algorithms for automated segmentation of the lumen borders in carotid ultrasound images. Both algorithms are modeled as a two stage process. Stage one consists of a global-based model using scale-space framework for the extraction of the region of interest. This stage is common to both algorithms. Stage two is modeled using a local-based strategy that extracts the lumen interfaces. At this stage, the algorithm-1 is modeled as a region-based strategy using a classification framework, whereas the algorithm-2 is modeled as a boundary-based approach that uses the level set framework. Two sets of databases (DB), Japan DB (JDB) (202 patients, 404 images) and Hong Kong DB (HKDB) (50 patients, 300 images) were used in this study. Two trained neuroradiologists performed manual LD tracings. The mean automated LD measured was 6.35 ± 0.95 mm for JDB and 6.20 ± 1.35 mm for HKDB. The precision-of-merit was: 97.4 % and 98.0 % w.r.t to two manual tracings for JDB and 99.7 % and 97.9 % w.r.t to two manual tracings for HKDB. Statistical tests such as ANOVA, Chi-Squared, T-test, and Mann-Whitney test were conducted to show the stability and reliability of the automated techniques.

  11. 40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...

  12. An In Vitro Aerosolization Efficiency Comparison of Generic and Branded Salbutamol Metered Dose Inhalers

    Directory of Open Access Journals (Sweden)

    Sara Rahimkhani, Saeed Ghanbarzadeh, Ali Nokhodchi, Hamed Hamishehkar

    2017-03-01

    Full Text Available Background: Due to the high rate of pulmonary diseases, respiratory drug delivery systems have been attracted excessive attention for the past decades. Because of limitations and growing drug bill, physicians are encouraged to prescribe generically whenever possible. The purpose of this study was to evaluate whether there was any significant difference in aerosolization performance between a reference brand Salbutamol (A Metered Dose Inhalers (MDIs and two generic products (B and C. Methods: The aerosolization performance of MDIs was evaluated by calculating aerosolization indexes including fine particle fraction (FPF, fine particle dose (FPD, geometric standard deviation (GSD and mass median aerodynamic diameters (MMAD by using the next generation impactor. Results: Although aerosolization indexes of MDI A were superior than the Iranian brands, but the differences were not statistically significant. Conclusion: These results verified that generic MDIs deliver similar quantities of Salbutamol to the reference brand and aerosolization performance parameters of generic Salbutamol MDIs did not differ significantly from the reference brand.

  13. ATD-2 Surface Scheduling and Metering Concept

    Science.gov (United States)

    Coppenbarger, Richard A.; Jung, Yoon Chul; Capps, Richard Alan; Engelland, Shawn A.

    2017-01-01

    This presentation describes the concept of ATD-2 tactical surface scheduling and metering. The concept is composed of several elements, including data exchange and integration; surface modeling; surface scheduling; and surface metering. The presentation explains each of the elements. Surface metering is implemented to balance demand and capacity• When surface metering is on, target times from surface scheduler areconverted to advisories for throttling demand• Through the scheduling process, flights with CTOTs will not get addedmetering delay (avoids potential for ‘double delay’)• Carriers can designate certain flights as exempt from metering holds• Demand throttle in Phase 1 at CLT is through advisories sent to rampcontrollers for pushback instructions to the flight deck– Push now– Hold for an advised period of time (in minutes)• Principles of surface metering can be more generally applied to otherairports in the NAS to throttle demand via spot-release times (TMATs Strong focus on optimal use of airport resources• Flexibility enables stakeholders to vary the amount of delay theywould like transferred to gate• Addresses practical aspects of executing surface metering in aturbulent real world environment• Algorithms designed for both short term demand/capacityimbalances (banks) or sustained metering situations• Leverage automation to enable surface metering capability withoutrequiring additional positions• Represents first step in Tactical/Strategic fusion• Provides longer look-ahead calculations to enable analysis ofstrategic surface metering potential usage

  14. Additional functions of remotely read kWh-meters

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P [VTT Energy, Espoo (Finland); Vehvilaeinen, S [Mittrix Oy (Finland); Rantanen, J [Helsinki Energy Board (Finland)

    1998-08-01

    In this chapter the possibilities to include new applications into remotely read smart kWh-meters are considered. New electronic meters can measure various electric quantities and have some extra calculating capacity. So they can be used to provide functions that distribution automation and the customer need and thus share the costs. Some applications like monitoring the state of the distribution network or locating faults are only for the utility, but many applications also need an interface to the customers or their automation systems. Among those are monitoring the quality of electricity, estimating load curves, applying dynamic tariffs and selling electricity and accounting. As a special item, the continuous monitoring of the quality of electricity is discussed. This includes voltage levels, total distortion, asymmetry and so on. If such a kWh-meter indicates quality problems it is possible to go there with a portable quality meter that is suitable for the case and inspect the situation. The poor quality can be detected before it causes harm to equipment owned by the customers or the power distribution company. This article also presents a prototype of such a quality monitoring kWh-meter. Dynamic tariffs and free electricity markets require two way communication with the utility and the customer and measurement of the time variations of the energy consumption. The customers or their energy management system must receive the energy prices from the utility and calculate the energy costs and decide upon the energy consumption control actions. Some alternative ways to meet these customer interface requirements are compared. Remote reading of kWh-meters requires a certain investment in meters and their data communication with the utility. Because smart meters can have some additional memory and calculating capacity and are capable of measuring various electric quantities, it is possible to share the costs with other applications that use the same hardware and data

  15. Digital reactivity meter

    International Nuclear Information System (INIS)

    Akkus, B.; Anac, H.; Alsan, S.; Erk, S.

    1991-01-01

    Nowadays, various digital methods making use of microcomputers for neutron detector signals and determining the reactivity by numerical calculations are used in reactor control systems in place of classical reactivity meters. In this work, a calculation based on the ''The Time Dependent Transport Equation'' has been developed for determining the reactivity numerically. The reactivity values have been obtained utilizing a computer-based data acquisition and control system and compared with the analog reactivity meter values as well as the values calculated from the ''Inhour Equation''

  16. A radon meter chamber

    International Nuclear Information System (INIS)

    Carlsson, R.

    1990-01-01

    The meter consists of a cylindrical house with two openings, at the ends, one of which is equipped with an alpha particle detector and the other covered with a metal net. The house is manufactured in an isolating material e.g. plastic, with a metallic layer applied to all internal surfaces. The metallic layer and net are kept at a positive electric potential, compared to the alpha detector, in order to attract the radon daughters to the detector and achieve a high efficiency. (L.E.)

  17. VLBI observations with the Kunming 40-meter radio telescope

    International Nuclear Information System (INIS)

    Hao Longfei; Wang Min; Yang Jun

    2010-01-01

    The Kunming 40-meter radio telescope is situated in the yard of the Yunnan Astronomical Observatory (Longitude: 102.8 0 East, Latitude: 25.0 0 North) and saw its first light in 2006 May. The Kunming station successfully joined the VLBI tracking of China's first lunar probe 'Chang'E-1 together with the other Chinese telescopes: the Beijing Miyun 50-meter radio telescope, Urumqi Nanshan 25-meter radio telescope, and Shanghai Sheshan 25-meter radio telescope, and received the downlinked scientific data together with the Miyun station from October of 2007 to March of 2009. We give an introduction to the new Chinese VLBI facility and investigate its potential applications. Due to its location, the Kunming station can significantly improve the u - v coverage of the European VLBI Network (EVN), in particular, in long baseline observations. We also report the results of the first EVN fringe-test experiment of N09SX1 with the Kunming station. The first fringes in the European telescopes were successfully detected at 2.3 GHz with the ftp-transferred data on 2009 June 17. From scheduling the observations to performing the post correlations, the Kunming station shows its good compatibility to work with the EVN. The imaging result of the extended source 1156+295 further demonstrates that the Kunming station greatly enhances the EVN performance. (research papers)

  18. Theoretical comparison of performance using transfer functions for reactivity meters based on inverse kinetic method and simple feedback method

    International Nuclear Information System (INIS)

    Shimazu, Yoichiro; Tashiro, Shoichi; Tojo, Masayuki

    2017-01-01

    The performance of two digital reactivity meters, one based on the conventional inverse kinetic method and the other one based on simple feedback theory, are compared analytically using their respective transfer functions. The latter one is proposed by one of the authors. It has been shown that the performance of the two reactivity meters become almost identical when proper system parameters are selected for each reactivity meter. A new correlation between the system parameters of the two reactivity meters is found. With this correlation, filter designers can easily determine the system parameters for the respective reactivity meters to obtain identical performance. (author)

  19. Automated borehole gravity meter system

    International Nuclear Information System (INIS)

    Lautzenhiser, Th.V.; Wirtz, J.D.

    1984-01-01

    An automated borehole gravity meter system for measuring gravity within a wellbore. The gravity meter includes leveling devices for leveling the borehole gravity meter, displacement devices for applying forces to a gravity sensing device within the gravity meter to bring the gravity sensing device to a predetermined or null position. Electronic sensing and control devices are provided for (i) activating the displacement devices, (ii) sensing the forces applied to the gravity sensing device, (iii) electronically converting the values of the forces into a representation of the gravity at the location in the wellbore, and (iv) outputting such representation. The system further includes electronic control devices with the capability of correcting the representation of gravity for tidal effects, as well as, calculating and outputting the formation bulk density and/or porosity

  20. A simple reactivity-meter system

    International Nuclear Information System (INIS)

    Ferreira, P.S.B.

    1992-01-01

    This paper describes a new version of a reactivity meter developed at the Institute of Nuclear Energy Research (IPEN) (Brazil). The reactivity meter computes the reactor reactivity utilizing a programmable electrometer that performs the data aquisition. The software commands the main functions of the electrometer, the data acquisition, data transfer, and reactivity calculation. The necessary hardware for this reactivity meter are a programmable electrometer, a microcomputer, and interfaces for the microcomputer to communicate with the electrometer. If it is necessary, it is possible to connect a graphic register to the microcomputer. With this conventional hardware, available in any nuclear reactor facility, one can build a powerful reactivity meter. Adding to these advantages, one can use the microcomputer on-line to analyze the data, store the data on diskettes, or create graphics

  1. MULTICHANNEL DISTRIBUTION METER: A VERITABLE ...

    African Journals Online (AJOL)

    eobe

    Usually, commercial home owners preferred the installation of one or few .... communication (GSM) based solution were presented. The authors ... meters. The proposed meters in their work uses .... The most probable data entry component to ...

  2. Hydro Ottawa achieves Smart Meter milestone

    International Nuclear Information System (INIS)

    Anon.

    2008-01-01

    As Ontario's second largest municipal electricity company, Hydro Ottawa serves more than 285,000 residential and business customers in the city of Ottawa and the village of Casselman. Since 2006, the utility has installed more than 230,000 Smart Meters throughout its service territory in an effort to provide better services to its customers. This initiative represents the largest operational advanced metering infrastructure network in Canada. This move was necessary before time-of-use rates can be implemented in Ottawa. The Smart Meters deliver data wirelessly to Hydro Ottawa's Customer Information System for billing and eliminating manual readings. The Smart Meters are designed to promote more efficient use of electricity. The Government of Ontario has passed legislation requiring the installation of Smart Meters throughout the province by the end of 2010

  3. How Satisfied Are Patients When Their Choice of Funded Glucose Meter Is Restricted to a Single Brand?

    Science.gov (United States)

    Macdonald, Christy; Lunt, Helen; Downie, Michelle; Kendall, Deborah

    2017-09-01

    Many governments and insurers are driving down the cost of medical devices, including glucose meters, by the central management of purchasing decisions. We report patients' responses to an "enforced" change in brand of glucose meter, one year after the introduction of a national sole supplier arrangement for funded glucose meters and strips. Specialist diabetes clinic attendees from two geographical locations completed a questionnaire one year after the final meter changeover date. In the first location, consecutive patients were asked to complete a glucose meter satisfaction questionnaire during their clinic visit. In the second location, this questionnaire was mailed to clinic attendees. Responses to open questions were analyzed thematically. Response rates were 85% and 31% from the first and second locations, respectively and 378 questionnaires were suitable for analysis, 309 from the first and 69 from the second location. Insulin users composed 90% of participants. Results from the two locations were broadly similar. Most participants adapted well to the changeover, however 36% reported ongoing dissatisfaction with their "new" meter. The commonest concern, expressed by 23% of participants, related to meter accuracy and precision. One year after glucose meter changeover, a third of participants expressed dissatisfaction with their meter, with many participants describing a failure to adapt to the sole supplier arrangement. Providing a choice of meters and strips, ideally from two or more brands that have demonstrable differences in technical and ergonomic features, is likely to produce higher overall patient satisfaction than is a sole supplier arrangement.

  4. PELATIHAN LARI AEROBIK 400 METER TIGA REPETISI DUA SET DAN DUA REPETISI TIGA SET SELAMA 6 MINGGU SAMA-SAMA MENINGKATKAN KECEPATAN JALAN CEPAT 3000 METER SISWA KELAS VII SMPN 11 DENPASAR

    Directory of Open Access Journals (Sweden)

    Dixon E.M. Taek Bete

    2014-08-01

    Full Text Available Monitoring the author has been in SMP 11 Denpasar.They had never achieved maximum performance (champion in the number of brisk walking.Because by declining student motivation, student interest because it appears more inclined to form other sports, such as volleyball ball games, soccer, futsall, table tennis or badminton or perhaps training methods that do not follow the principles of training required. The purpose of this training is to determine an increase in the speed of a brisk walk 3000 meters against both treatment groups. This study used an experimental method. Population is taken from class VII SMP Denpasar. This study used an experimental method. Population is taken from class VII SMP Denpasar. Samples are 32 people drawn randomly from the population who meet the inclusion and exclusion criteria. The number of samples divided into two groups with each group consisting of 16 people. The training is done with a frequency 4 times a week for 6 weeks. The first group was given 400-meter aerobic training run two sets of three reps and group II aerobic training 400 meter run three sets of two reps. Data in the form of brisk walking 3000 meter results taken before and after training. The data obtained were tested using SPSS computer program. The data were normally distributed and homogeneous so that further tested using paired t-test to compare mean values ??before and after training between each group, while the independent t-test to determine differences in mean values ??between the two groups. Paired t-test results of Group I and Group II were significantly increased (p <0.05. The results of independent t-test found that the two groups before the training was not significant (p> 0.05, whereas both groups after training pace brisk walking are equally increased (p> 0.05. Conclusion that aerobic training 400 meter run two sets of three reps and three sets of two reps for 6 weeks together (not significant increase the speed of a brisk walk 3000

  5. Probing attentive and preattentive emergent meter in adult listeners without extensive music training

    NARCIS (Netherlands)

    Ladinig, O.; Honing, H.; Háden, G.; Winkler, I.

    2009-01-01

    Beat and meter induction are considered important structuring mechanisms underlying the perception of rhythm. Meter comprises two or more levels of hierarchically ordered regular beats with different periodicities. When listening to music, adult listeners weight events within a measure in a

  6. Two-point method uncertainty during control and measurement of cylindrical element diameters

    Science.gov (United States)

    Glukhov, V. I.; Shalay, V. V.; Radev, H.

    2018-04-01

    The topic of the article is devoted to the urgent problem of the reliability of technical products geometric specifications measurements. The purpose of the article is to improve the quality of parts linear sizes control by the two-point measurement method. The article task is to investigate methodical extended uncertainties in measuring cylindrical element linear sizes. The investigation method is a geometric modeling of the element surfaces shape and location deviations in a rectangular coordinate system. The studies were carried out for elements of various service use, taking into account their informativeness, corresponding to the kinematic pairs classes in theoretical mechanics and the number of constrained degrees of freedom in the datum element function. Cylindrical elements with informativity of 4, 2, 1 and θ (zero) were investigated. The uncertainties estimation of in two-point measurements was made by comparing the results of of linear dimensions measurements with the functional diameters maximum and minimum of the element material. Methodical uncertainty is formed when cylindrical elements with maximum informativeness have shape deviations of the cut and the curvature types. Methodical uncertainty is formed by measuring the element average size for all types of shape deviations. The two-point measurement method cannot take into account the location deviations of a dimensional element, so its use for elements with informativeness less than the maximum creates unacceptable methodical uncertainties in measurements of the maximum, minimum and medium linear dimensions. Similar methodical uncertainties also exist in the arbitration control of the linear dimensions of the cylindrical elements by limiting two-point gauges.

  7. License - MicrobeDB.jp | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available List Contact us MicrobeDB.jp License License to Use This Database Last updated : 2017/06/29 You may use this database...the license terms regarding the use of this database and the requirements you must follow in using this database.... The license for this database is specified in the Creative Commons Attribut...ion-Share Alike 4.0 International . If you use data from this database, please be sure attribute this database... Creative Commons Attribution-Share Alike 4.0 International is found here . With regard to this database, yo

  8. Privacy-Preserving Meter Report Protocol of Isolated Smart Grid Devices

    Directory of Open Access Journals (Sweden)

    Zhiwei Wang

    2017-01-01

    Full Text Available Smart grid aims to improve the reliability, efficiency, and security of the traditional grid, which allows two-way transmission and efficiency-driven response. However, a main concern of this new technique is that the fine-grained metering data may leak the personal privacy information of the customers. Thus, the data aggregation mechanism for privacy protection is required for the meter report protocol in smart grid. In this paper, we propose an efficient privacy-preserving meter report protocol for the isolated smart grid devices. Our protocol consists of an encryption scheme with additively homomorphic property and a linearly homomorphic signature scheme, where the linearly homomorphic signature scheme is suitable for privacy-preserving data aggregation. We also provide security analysis of our protocol in the context of some typical attacks in smart grid. The implementation of our protocol on the Intel Edison platform shows that our protocol is efficient enough for the physical constrained devices, like smart meters.

  9. Justification of the Utility of Introducing Smart Meters in Latvia

    Science.gov (United States)

    Kunickis, M.; Dandens, A.; Bariss, U.

    2015-12-01

    Automatic data reading from smart meters is being developed in many parts of the world, including Latvia. The key drivers for that are developments of smart technologies and economic benefits for consumers. Deployment of smart meters could be launched in a massive scale. Several pilot projects were implemented to verify the feasibility of smart meters for individual consumer groups. Preliminary calculations indicate that installation of smart meters for approximately 23 % of electricity consumers would be economically viable. Currently, the data for the last two years is available for an in-depth mathematical analysis. The continuous analysis of consumption data would be established, when more measurements from smart meters are available. The extent of introduction of smart meters should be specified during this process in order to gain the maximum benefit for the whole society (consumers, grid companies, state authorities), because there are still many uncertain and variable factors. For example, it is necessary to consider statistical load variations by hour, dependence of electricity consumption on temperature fluctuations, consumer behaviour and demand response to market signals to reduce electricity consumption in the short and long term, consumer's ambitions and capability to install home automation for regulation of electricity consumption. To develop the demand response, it is necessary to analyse the whole array of additional factors, such as expected cost reduction of smart meters, possible extension of their functionality, further development of information exchange systems, as well as standard requirements and different political and regulatory decisions regarding the reduction of electricity consumption and energy efficiency.

  10. Increases of Chamber Height and Base Diameter Have Contrasting Effects on Grazing Rate of Two Cladoceran Species: Implications for Microcosm Studies

    Science.gov (United States)

    Pan, Ying; Zhang, Yunshu; Peng, Yan; Zhao, Qinghua; Sun, Shucun

    2015-01-01

    Aquatic microcosm studies often increase either chamber height or base diameter (to increase water volume) to test spatial ecology theories such as “scale” effects on ecological processes, but it is unclear whether the increase of chamber height or base diameter have the same effect on the processes, i.e., whether the effect of the shape of three-dimensional spaces is significant. We orthogonally manipulated chamber height and base diameter and determined swimming activity, average swimming velocity and grazing rates of the cladocerans Daphnia magna and Moina micrura (on two algae Scenedesmus quadricauda and Chlorella vulgaris; leading to four aquatic algae-cladoceran systems in total) under different microcosm conditions. Across all the four aquatic systems, increasing chamber height at a given base diameter significantly decreased the duration and velocity of horizontal swimming, and it tended to increase the duration but decrease the velocity of vertical swimming. These collectively led to decreases in both average swimming velocity and grazing rate of the cladocerans in the tall chambers (at a given base diameter), in accordance with the positive relationship between average swimming velocity and grazing rate. In contrast, an increase of base diameter at a given chamber height showed contrasting effects on the above parameters. Consistently, at a given chamber volume increasing ratio of chamber height to base diameter decreased the average swimming velocity and grazing rate across all the aquatic systems. In general, increasing chamber depth and base diameter may exert contrasting effects on zooplankton behavior and thus phytoplankton-zooplankton interactions. We suggest that spatial shape plays an important role in determining ecological process and thus should be considered in a theoretical framework of spatial ecology and also the physical setting of aquatic microcosm experiments. PMID:26273836

  11. File list: His.Emb.05.AllAg.4-8h_embryos [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Emb.05.AllAg.4-8h_embryos dm3 Histone Embryo 4-8h embryos SRX013093,SRX013021,S...RX013027,SRX013026,SRX013028,SRX013102 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/His.Emb.05.AllAg.4-8h_embryos.bed ...

  12. File list: Unc.Emb.10.AllAg.8-16h_embryos [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Emb.10.AllAg.8-16h_embryos dm3 Unclassified Embryo 8-16h embryos SRX025491,SRX0...25483,SRX026868,SRX026870,SRX025481,SRX025465 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Unc.Emb.10.AllAg.8-16h_embryos.bed ...

  13. In vitro propagation and organogenesis of Lilium 'Prato'

    African Journals Online (AJOL)

    Hany ElNaggar

    2012-10-11

    Oct 11, 2012 ... containing 4.43 g/l MS with vitamins (Murashige and Skoog, 1962) supplemented ... adjusted at 5.8 ± 0.1 and poured in tubes (2.5 cm diameter × 15 cm height). ..... Nitsch JP, Nitsch C, Rossini LM, Ha DB (1967). The role of ...

  14. 40 CFR Table 25 to Subpart G of... - Effective Column Diameter (Fc)

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Effective Column Diameter (Fc) 25 Table..., Table 25 Table 25 to Subpart G of Part 63—Effective Column Diameter (Fc) Column type Fc (feet) 9-inch by 7-inch built-up columns 1.1 8-inch-diameter pipe columns 0.7 No construction details known 1.0 ...

  15. Accurate KAP meter calibration as a prerequisite for optimisation in projection radiography

    International Nuclear Information System (INIS)

    Malusek, A.; Sandborg, M.; Alm Carlsson, G.

    2016-01-01

    Modern X-ray units register the air kerma-area product, PKA, with a built-in KAP meter. Some KAP meters show an energy-dependent bias comparable with the maximum uncertainty articulated by the IEC (25 %), adversely affecting dose-optimisation processes. To correct for the bias, a reference KAP meter calibrated at a standards laboratory and two calibration methods described here can be used to achieve an uncertainty of <7 % as recommended by IAEA. A computational model of the reference KAP meter is used to calculate beam quality correction factors for transfer of the calibration coefficient at the standards laboratory, Q 0 , to any beam quality, Q, in the clinic. Alternatively, beam quality corrections are measured with an energy-independent dosemeter via a reference beam quality in the clinic, Q 1 , to beam quality, Q. Biases up to 35 % of built-in KAP meter readings were noted. Energy-dependent calibration factors are needed for unbiased PKA. Accurate KAP meter calibration as a prerequisite for optimisation in projection radiography. (authors)

  16. Dynamic range meter for radiofrequency amplifiers

    Directory of Open Access Journals (Sweden)

    Drozd S. S.

    2009-04-01

    Full Text Available The new measurement setup having increased on 20…30 dB the own dynamic range in comparison with the standard circuit of the dynamic range meter is offered and the rated value of an error bringing by setup in the worst case does not exceed ± 2,8 dB. The measurement setup can be applied also to determinate levels of intermodulation components average power amplifiers and powerful amplifiers of a low-frequency at replacement of the quartz filter on meeting low-frequency the LC-filter and the spectrum analyzer.

  17. Radioisotope conveyor ash meter

    International Nuclear Information System (INIS)

    Savelov, V.D.

    1994-01-01

    Radioisotope conveyor ash meter realizes persistent measuring of ashiness of coal and products of its enrichment on the belt conveyor without contact. The principle of ash meter acting is based on functional dependence of the gamma radiation flows backscattering intensity of radioisotope sources from the ash volume content in the controlled fuel. Facility consists from the ashiness transducer and the processing and control device

  18. Effect of Doppler flow meter position on discharge measurement in surcharged manholes.

    Science.gov (United States)

    Yang, Haoming; Zhu, David Z; Liu, Yanchen

    2018-02-01

    Determining the proper installation location of flow meters is important for accurate measurement of discharge in sewer systems. In this study, flow field and flow regimes in two types of manholes under surcharged flow were investigated using a commercial computational fluid dynamics (CFD) code. The error in measuring the flow discharge using a Doppler flow meter (based on the velocity in a Doppler beam) was then estimated. The values of the corrective coefficient were obtained for the Doppler flow meter at different locations under various conditions. Suggestions for selecting installation positions are provided.

  19. Intelligent Metering for Urban Water: A Review

    OpenAIRE

    Rodney Stewart; Stuart White; Candice Moy; Ariane Liu; Pierre Mukheibir; Damien Giurco; Thomas Boyle

    2013-01-01

    This paper reviews the drivers, development and global deployment of intelligent water metering in the urban context. Recognising that intelligent metering (or smart metering) has the potential to revolutionise customer engagement and management of urban water by utilities, this paper provides a summary of the knowledge-base for researchers and industry practitioners to ensure that the technology fosters sustainable urban water management. To date, roll-outs of intelligent metering have been ...

  20. Main trends of cooperation of physicists in socialist countries

    International Nuclear Information System (INIS)

    Biryukov, V.

    1978-01-01

    The work of JINR at Dubna, the first international scientific centre of socialist countries, is focused on studies in theoretical physics, high energy physics, nuclear physics, and low energy physics. Results are described obtained so far in the above fields as well as computer technology and data processing. JINR is also a centre for accelerator technology work. The U-300 three-meter cyclotron and the U-200 two-meter isochronous cyclotron were installed and the U-400 four-meter cyclotron is being built. The experience of JINR shows that the institute has become an educational facility for scientists and specialists from the participating countries. (J.P.)

  1. 29 mm Diameter Target Test Report

    Energy Technology Data Exchange (ETDEWEB)

    Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Olivas, Eric Richard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Naranjo, Angela Carol [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chemerisov, Sergey [Argonne National Lab. (ANL), Argonne, IL (United States); Gromov, Roman [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-10-23

    After numerous delays, the test of the 29 mm diameter target was conducted on 8/18/2017. The complete target design report, dated 8/15/2016, is reproduced below for completeness. This describes in detail the 10 disk target with varying thickness disks. The report presents and discusses the test results. In brief summary, there appears to have been multiple instrumentation errors. Measured temperatures, pressures and IR camera window temperature measurement are all suspect. All tests were done at 35 MeV, with 171 μA current, or 6 kW of beam power.

  2. Retrobulbar diameter of optic nerve in glaucoma

    Directory of Open Access Journals (Sweden)

    Stefanović Ivan

    2009-01-01

    Full Text Available Introduction. The ultrasound diagnostics of the optic nerve includes the analysis of the optic nerve disc (PNO and measuring of its retrobulbar diameter. With B-scan, by Schraeder's method, it is possible to measure very precisely the optic nerve, the pial diameter, the normal values for the pial diameter being 2.8-4.1 mm. In glaucoma, the disease that is most frequently associated with higher intraocular pressure, there comes the destruction of nerve fibres, which can be visualized as the excavation of the optic nerve disc. Objective. In this paper, we were interested in finding whether in glaucoma, and in what phase of the disease, the optic nerve starts growing thinner. Aware of many forms of this very complex disease, we were interested in knowing if the visualization of excavation on the optic nerve disc is related to diminishing of the pial diameter of the retrobulbar nerve part. Methods. There were treated the patients who had already had the diagnosis of glaucoma and the visualized excavation of the optic disc of various dimensions. Echographically, there was measured the thickness of the retrobulbar part of the optic nerve and the finding compared in relation to the excavation of the optic disc. Results. In all eyes with glaucoma, a normal size of the retrobulbar part of the optic nerve was measured, ranging from 3.01 to 3.91 mm with the median of 3.36 mm. Also, by testing the correlation between the thickness of the optic nerve and the excavation of the PNO, by Pearson test, we found that there was no correlation between these two parameters (r=0.109; p>0.05. Conclusion. In the patients with glaucoma, the retrobulbar part of the optic nerve is not thinner (it has normal values, even not in the cases with a totally excavated optic disc. There is no connection between the size of the PNO excavation and the thickness of the retrobulbar part of the optic nerve.

  3. Strategy of the spread of automatic meter reading for 10 million customers

    International Nuclear Information System (INIS)

    Okano, H.; Koyanagi, A.

    1997-01-01

    In response to the major changes now taking place in its business environment, Tokyo Gas will restructure its meter-reading operations, including services peripheral thereto, to build a strong corporate structure toward the year 2010. Specifically, Tokyo Gas will proceed to intentional automatic meter reading, making use of the know-how it has accumulated doing so as part of a value-added service it has been marketing since 1988. Tokyo Gas will also use its two-way communication infrastructure to promote improved operational efficiency and labor savings. Intentional automatic meter reading will enable Tokyo Gas, over the 13 years following its commencement, to realize total cost savings of 53.5 billion yen and reassign 776 employers to strategic work. Tokyo Gas will also utilize its two-way communication infrastructure to provide additional services, including value-added services that will generate upwards of 3.7 billion yen margin annually and contracted meter reading services for utilities throughout Japan. Tokyo Gas will thus carry out a business expansion that will enable it to grow limitlessly together with society. (au)

  4. Clean water billing monitoring system using flow liquid meter sensor and SMS gateway

    Science.gov (United States)

    Fahmi, F.; Hizriadi, A.; Khairani, F.; Andayani, U.; Siregar, B.

    2018-03-01

    Public clean water company (PDAM) as a public service is designed and organized to meet the needs of the community. Currently, the number of PDAM subscribers is very big and will continue to grow, but the service and facilities to customers are still done conventionally by visiting the customer’s home to record the last position of the meter. One of the problems of PDAM is the lack of disclosure of PDAM customers’ invoice because it is only done monthly. This, of course, makes PDAM customers difficult to remember the date of payment of water account. Therefore it is difficult to maintain the efficiency. The purpose of this research is to facilitate customers of PDAM water users to know the details of water usage and the time of payment of water bills easily. It also facilitates customers in knowing information related to the form of water discharge data used, payment rates, and time grace payments using SMS Gateway. In this study, Flow Liquid Meter Sensor was used for data retrieval of water flowing in the piping system. Sensors used to require the help of Hall Effect sensor that serves to measure the speed of water discharge and placed on the pipe that has the same diameter size with the sensor diameter. The sensor will take the data from the rate of water discharge it passes; this data is the number of turns of the mill on the sensor. The results of the tests show that the built system works well in helping customers know in detail the amount of water usage in a month and the bill to be paid

  5. Meter-wavelength VLBI. III. Pulsars

    International Nuclear Information System (INIS)

    Vandenberg, N.R.; Clark, T.A.; Clark, W.C.; Erickson, W.C.; Resch, G.M.; Broderick, J.J.

    1976-01-01

    The results and analysis of observations of pulsars, especially the Crab Nebula pulsar, taken during a series of meter-wavelength very long baseline interferometry (VLBI) experiments are discussed. Based on a crude 144 MHz visibility curve which is consistent with a Gaussian brightness distribution, the measured visibilities at 196, 111, and 74 MHz were interpreted to yield apparent angular diameters (at half-power) of 0 .03 +- 0 .01, 0 .07 +- 0 .01, and 0 .18 +- 0 .01, respectively. These sizes scale approximately as wavelength-squared, and the 74 MHz size agrees with recent observations using interplanetary scintillation techniques.The VLBI-measured total flux densities lie on the extrapolation from higher frequencies of the pulsing flux densities. Variations in the total flux density up to 25 percent were observed. A lack of fine structure other than the pulsar in the nebula is indicated by our simple visibility curves. The pulse shapes observed with the interferometer are similar to single-dish measurements at 196 MHz but reveal a steady, nonpulsing component at 111 MHz. The ratio of pulsing to total power was approximately equal to one-half but varied with time. No pulsing power was detected at 74 MHz. It was found that four strong, low-dispersion pulsars were only slightly resolved

  6. Critical review of directional neutron survey meters

    International Nuclear Information System (INIS)

    Balmer, Matthew J.I.; Gamage, Kelum A.A.; Taylor, Graeme C.

    2014-01-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument. -- Highlights: • We critically review the existing literature into directional survey meters. • Instruments which could be adapted for this purpose are also reviewed. • Investigate the potential of much lighter portable real-time instrument. • Improvements to existing instruments are suggested to improve their design. • Boron-Doped liquid scintillator design is the most promising, but needs further work

  7. Numerical investigation on effect of riser diameter and inclination on system parameters in a two-phase closed loop thermosyphon solar water heater

    International Nuclear Information System (INIS)

    Aung, Nay Zar; Li, Songjing

    2013-01-01

    Highlights: • Optimum inclination for maximum heat flux changes with latitude of location. • Optimum inclination for maximum heat flux also changes local solar time. • Maximum flow rate increases with increasing of riser tube size. • Maximum mass flow rate is obtained at different inclinations for different risers. • Length of two-phase region depends on inclination angles but not riser tube size. - Abstract: In this work, the effect of riser diameter and its inclination angle on system parameters in a two-phase closed loop thermosyphon solar water heater has been numerically investigated. Here, receivable heat flux by the collector, circulating mass flow rate, driving pressure, total pressure drop, heat transfer coefficient in risers and collector efficiency are defined as system parameters. For this aim, a model of two-phase thermosyphon solar water heater that is acceptable for various inclinations is presented and variations of riser diameter and inclination are considered. The riser tube size is varied from 1.25 cm to 2.5 cm with inclination range 2–75°. The system absolute pressure is set as 3567 Pa and water is chosen as working fluid. The results show that higher inclination angle is required for higher latitude location to obtain maximum solar heat flux. At local solar noon of 21.996 north latitude, the optimum inclination angle increases in the range of 24–44° with increasing of riser diameter giving maximum circulating mass flow rate from 0.02288 kg/s to 0.03876 kg/s. The longer two-phase heat transfer characteristics can be obtained at smaller inclination angles and mass flow rate for all riser tube sizes. Therefore, it is observed that the optimum inclination angles and diameters for solar heat flux, circulating mass flow rate and heat transfer coefficient in two-phase thermosyphon systemdo not coincide. From this work, better understanding and useful information are provided for constructing two-phase thermosyphon solar heaters

  8. Portable radiation meters developed in Boris Kidric Institute

    International Nuclear Information System (INIS)

    Sobajic, V.; Smelcerovic, M.

    1989-01-01

    Portable meters designed for X and gamma radiation measurements and beta detection are described. An instrument using ionization chamber is developed with new type of electrometer amplifier. It is designed for precise and reliable exposure and exposure rate measurements. Another instrument with GM counters covers 8 linear ranges: from background up to 10 Sv/h. Some specific solutions and basic measurement characteristics of these instruments are presented (author)

  9. Ambiguity effects of rhyme and meter.

    Science.gov (United States)

    Wallot, Sebastian; Menninghaus, Winfried

    2018-04-23

    Previous research has shown that rhyme and meter-although enhancing prosodic processing ease and memorability-also tend to make semantic processing more demanding. Using a set of rhymed and metered proverbs, as well as nonrhymed and nonmetered versions of these proverbs, the present study reveals this hitherto unspecified difficulty of comprehension to be specifically driven by perceived ambiguity. Roman Jakobson was the 1st to propose this hypothesis, in 1960. He suggested that "ambiguity is an intrinsic, inalienable feature" of "parallelistic" diction of which the combination of rhyme and meter is a pronounced example. Our results show that ambiguity indeed explains a substantial portion of the rhyme- and meter-driven difficulty of comprehension. Longer word-reading times differentially reflected ratings for ambiguity and comprehension difficulty. However, the ambiguity effect is not "inalienable." Rather, many rhymed and metered sentences turned out to be low in ambiguity. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  10. 39 CFR 501.15 - Computerized Meter Resetting System.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at...

  11. Numerical Simulation Analysis of Five-Step Variable-Diameter Pipe with Solid-Liquid Two-Phase Abrasive Flow Polishing

    Science.gov (United States)

    Li, Junye; Zhang, Hengfu; Wu, Guiling; Hu, Jinglei; Liu, Yang; Sun, Zhihui

    2018-01-01

    In many areas of precision machining abrasive flow polishing technology has an important role. In order to study the influence of abrasive flow on the polishing effect of variable diameter parts, the fifth step variable diameter tube was taken as the research object to analyze the dynamic pressure and turbulent kinetic energy distribution of inlet velocity on the fifth-order variable diameter tube influences. Through comparative analysis, the abrasive flow polished variable diameter pipe parts have very effective and significant polishing effect and the higher the inlet speed, the more significant the polishing effect.

  12. A Probabilistic Model of Meter Perception: Simulating Enculturation

    Directory of Open Access Journals (Sweden)

    Bastiaan van der Weij

    2017-05-01

    Full Text Available Enculturation is known to shape the perception of meter in music but this is not explicitly accounted for by current cognitive models of meter perception. We hypothesize that the induction of meter is a result of predictive coding: interpreting onsets in a rhythm relative to a periodic meter facilitates prediction of future onsets. Such prediction, we hypothesize, is based on previous exposure to rhythms. As such, predictive coding provides a possible explanation for the way meter perception is shaped by the cultural environment. Based on this hypothesis, we present a probabilistic model of meter perception that uses statistical properties of the relation between rhythm and meter to infer meter from quantized rhythms. We show that our model can successfully predict annotated time signatures from quantized rhythmic patterns derived from folk melodies. Furthermore, we show that by inferring meter, our model improves prediction of the onsets of future events compared to a similar probabilistic model that does not infer meter. Finally, as a proof of concept, we demonstrate how our model can be used in a simulation of enculturation. From the results of this simulation, we derive a class of rhythms that are likely to be interpreted differently by enculturated listeners with different histories of exposure to rhythms.

  13. EXATIDÃO DE DENDRÔMETROS ÓPTICOS PARA DETERMINAÇÃO DO VOLUME DE ÁRVORES EM PÉ

    Directory of Open Access Journals (Sweden)

    Marcos Felipe Nicoletti

    2015-01-01

    Full Text Available ABSTRACTThe aim of this paper is to verify the accuracy of the optical dendrometers Criterion 400 and RC3H bystudying the quality of measures of wood volume determination of standing trees through these dendrometers.The study was developed at the Experimental Station of Forest Sciences, in Itatinga, São Paulo state, whichbelongs to the University of São Paulo (ESALQ / USP. It was sampled a total of 175 trees in three plots ofEucalyptus grandis. The stem diameter of standing trees was measured by the two optical dendrometers atdistances of 0.1, 0.4, 0.7, 1.0, 1.3, 2.0 meters from this point meter by meter along the stem up to 8 metersheight. After measuring the standing trees they were felled and the diameter was obtained in differentpositions with a caliper and a tape in the same positions that the non-destructive measures were taken. Withthe diameters the volume was calculated by section and by individual trees by the Smalian formula forthe comparison of methods. Analyzing the measurements of stem diameter and the individual tree volume realizes that the two dendrometers provided measures generally underestimated. However, the Criterionprovided the best estimates. For the diameter and individual tree volume the Criterion showed underestimatederrors averaging approximately 1 cm (10%, while the RC3H resulted in errors greater than 5 cm (30% onaverage.Thus, when measuring observed variables in a non-destructive way with reliability and accuracy,the Criterion showed better results.

  14. 20-meter underwater wireless optical communication link with 15 Gbps data rate

    KAUST Repository

    Shen, Chao

    2016-10-24

    The video streaming, data transmission, and remote control in underwater call for high speed (Gbps) communication link with a long channel length (∼10 meters). We present a compact and low power consumption underwater wireless optical communication (UWOC) system utilizing a 450-nm laser diode (LD) and a Si avalanche photodetector. With the LD operating at a driving current of 80 mA with an optical power of 51.3 mW, we demonstrated a high-speed UWOC link offering a data rate up to 2 Gbps over a 12-meter-long, and 1.5 Gbps over a record 20-meter-long underwater channel. The measured bit-error rate (BER) are 2.8 × 10-5, and 3.0 × 10-3, respectively, which pass well the forward error correction (FEC) criterion. © 2016 Optical Society of America.

  15. 20-meter underwater wireless optical communication link with 15 Gbps data rate

    KAUST Repository

    Shen, Chao; Guo, Yong; Oubei, Hassan M.; Ng, Tien Khee; Liu, Guangyu; Park, Kihong; Ho, Kang-Ting; Alouini, Mohamed-Slim; Ooi, Boon S.

    2016-01-01

    The video streaming, data transmission, and remote control in underwater call for high speed (Gbps) communication link with a long channel length (∼10 meters). We present a compact and low power consumption underwater wireless optical communication (UWOC) system utilizing a 450-nm laser diode (LD) and a Si avalanche photodetector. With the LD operating at a driving current of 80 mA with an optical power of 51.3 mW, we demonstrated a high-speed UWOC link offering a data rate up to 2 Gbps over a 12-meter-long, and 1.5 Gbps over a record 20-meter-long underwater channel. The measured bit-error rate (BER) are 2.8 × 10-5, and 3.0 × 10-3, respectively, which pass well the forward error correction (FEC) criterion. © 2016 Optical Society of America.

  16. Instrument evaluation no. 8. Nuclear Enterprises beta/gamma dose rate meter type 0500

    International Nuclear Information System (INIS)

    Iles, W.J.; Burgess, P.H.; Callowhill, K.

    1977-04-01

    This instrument is a portable, battery powered survey meter covering the dose rate range from 0 to 10,000 mrad h -1 and the dose range 0 to 1000 mrad. The instrument was designed to measure X and γ-radiation dose and dose rate over a wide energy range, and also β-radiation dose and dose rate. An unsealed ionisation chamber is used as the detector. The aluminised melinex thin end window of the chamber is provided with a detachable plastic end cap. The calibration plane of the chamber is indicated by a cross on the side of the instrument. The information is given under the following headings: facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; summary of performance; conclusions. (U.K.)

  17. Developing high coercivity in large diameter cobalt nanowire arrays

    Science.gov (United States)

    Montazer, A. H.; Ramazani, A.; Almasi Kashi, M.; Zavašnik, J.

    2016-11-01

    Regardless of the synthetic method, developing high magnetic coercivity in ferromagnetic nanowires (NWs) with large diameters has been a challenge over the past two decades. Here, we report on the synthesis of highly coercive cobalt NW arrays with diameters of 65 and 80 nm, which are embedded in porous anodic alumina templates with high-aspect-ratio pores. Using a modified electrochemical deposition method enabled us to reach room temperature coercivity and remanent ratio up to 3000 Oe and 0.70, respectively, for highly crystalline as-synthesized hcp cobalt NW arrays with a length of 8 μm. The first-order reversal curve (FORC) analysis showed the presence of both soft and hard magnetic phases along the length of the resulting NWs. To develop higher coercive fields, the length of the NWs was then gradually reduced in order from bottom to top, thereby reaching NW sections governed by the hard phase. Consequently, this resulted in record high coercivities of 4200 and 3850 Oe at NW diameters of 65 and 80 nm, respectively. In this case, the FORC diagrams confirmed a significant reduction in interactions between the magnetic phases of the remaining sections of NWs. At this stage, x-ray diffraction (XRD) and dark-field transmission electron microscopy analyses indicated the formation of highly crystalline bamboo-like sections along the [0 0 2] direction during a progressive pulse-controlled electrochemical growth of NW arrays under optimized parameters. Our results both provide new insights into the growth process, crystalline characteristics and magnetic phases along the length of large diameter NW arrays and, furthermore, develop the performance of pure 3d transition magnetic NWs.

  18. Charge Meter

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 19; Issue 4. Charge Meter: Easy Way to Measure Charge and Capacitance: Some Interesting Electrostatic Experiments. M K Raghavendra V Venkataraman. Classroom Volume 19 Issue 4 April 2014 pp 376-390 ...

  19. A Probabilistic Model of Meter Perception: Simulating Enculturation

    NARCIS (Netherlands)

    van der Weij, B.; Pearce, M.T.; Honing, H.

    Enculturation is known to shape the perception of meter in music but this is not explicitly accounted for by current cognitive models of meter perception. We hypothesize that the induction of meter is a result of predictive coding: interpreting onsets in a rhythm relative to a periodic meter

  20. Neural processing of musical meter in musicians and non-musicians.

    Science.gov (United States)

    Zhao, T Christina; Lam, H T Gloria; Sohi, Harkirat; Kuhl, Patricia K

    2017-11-01

    Musical sounds, along with speech, are the most prominent sounds in our daily lives. They are highly dynamic, yet well structured in the temporal domain in a hierarchical manner. The temporal structures enhance the predictability of musical sounds. Western music provides an excellent example: while time intervals between musical notes are highly variable, underlying beats can be realized. The beat-level temporal structure provides a sense of regular pulses. Beats can be further organized into units, giving the percept of alternating strong and weak beats (i.e. metrical structure or meter). Examining neural processing at the meter level offers a unique opportunity to understand how the human brain extracts temporal patterns, predicts future stimuli and optimizes neural resources for processing. The present study addresses two important questions regarding meter processing, using the mismatch negativity (MMN) obtained with electroencephalography (EEG): 1) how tempo (fast vs. slow) and type of metrical structure (duple: two beats per unit vs. triple: three beats per unit) affect the neural processing of metrical structure in non-musically trained individuals, and 2) how early music training modulates the neural processing of metrical structure. Metrical structures were established by patterns of consecutive strong and weak tones (Standard) with occasional violations that disrupted and reset the structure (Deviant). Twenty non-musicians listened passively to these tones while their neural activities were recorded. MMN indexed the neural sensitivity to the meter violations. Results suggested that MMNs were larger for fast tempo and for triple meter conditions. Further, 20 musically trained individuals were tested using the same methods and the results were compared to the non-musicians. While tempo and meter type similarly influenced MMNs in both groups, musicians overall exhibited significantly reduced MMNs, compared to their non-musician counterparts. Further analyses

  1. Critical review of directional neutron survey meters

    Science.gov (United States)

    Balmer, Matthew J. I.; Gamage, Kelum A. A.; Taylor, Graeme C.

    2014-01-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument.

  2. Critical Review of Directional Neutron Survey Meters

    International Nuclear Information System (INIS)

    Balmer, M.J.I.; Gamage, K.A.A.; Taylor, G.C.

    2013-06-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument. (authors)

  3. Chondroprotective Effects of a Standardized Extract (KBH-JP-040) from Kalopanax pictus, Hericium erinaceus, and Astragalus membranaceus in Experimentally Induced In Vitro and In Vivo Osteoarthritis Models.

    Science.gov (United States)

    Rahman, Md Mahbubur; Kim, Hyun-Kyu; Kim, Seong-Eun; Kim, Myung-Jin; Kim, Do-Hyung; Lee, Hak Sung

    2018-03-15

    The aim of this study was to investigate the chondroprotective effect of a standardized extract (KBH-JP-040) of the Korean traditional herbs Kalopanax pictus Castor-Aralia, Hericium erinaceus (Bull.) Persoon, and Astragalus membranaceus Schischkin on in vivo and in vitro osteoarthritis (OA) models. Cultured rat chondrocytes were pre-treated with KBH-JP-040 (50, 100 and 200 μg/mL) for 1 h, then recombinant human IL-1α (rhIL-1α) for 24 h. For the in vivo model, rabbits ( n = 60) were equally divided into experimental groups: normal control (NC), a collagenase-induced OA group, and OA groups treated with KBH-JP-040 (75, 100, and 150 mg/kg body weight) and celecoxib (Cx, 100 mg/kg) orally for 28 days. Treatment with KBH-JP-040 significantly attenuated inflammatory cytokines and matrix metalloproteinases (MMPs), suppressed the expression of IκBα, NF-κB, and JNK/p38 mitogen-activated protein (MAP) kinase, and upregulated aggrecan and collagen type-II expression in rhIL-1α-stimulated chondrocytes. Furthermore, the serum and synovial levels of inflammatory cytokines of rabbits also decreased in the treatment groups when compared with the OA group. Improved magnetic resonance imaging and histopathological findings further confirmed the therapeutic efficacy of KBH-JP-040 against OA. In conclusion, these results indicate that KBH-JP-040 possesses chondroprotective effects, suppressing inflammation and MMPs, and downregulating IκBα, NF-κB, and JNK/p38 MAP kinase-signaling pathways. This might be a potential therapeutic candidate for OA treatment.

  4. Chondroprotective Effects of a Standardized Extract (KBH-JP-040 from Kalopanax pictus, Hericium erinaceus, and Astragalus membranaceus in Experimentally Induced In Vitro and In Vivo Osteoarthritis Models

    Directory of Open Access Journals (Sweden)

    Md. Mahbubur Rahman

    2018-03-01

    Full Text Available The aim of this study was to investigate the chondroprotective effect of a standardized extract (KBH-JP-040 of the Korean traditional herbs Kalopanax pictus Castor-Aralia, Hericium erinaceus (Bull. Persoon, and Astragalus membranaceus Schischkin on in vivo and in vitro osteoarthritis (OA models. Cultured rat chondrocytes were pre-treated with KBH-JP-040 (50, 100 and 200 μg/mL for 1 h, then recombinant human IL-1α (rhIL-1α for 24 h. For the in vivo model, rabbits (n = 60 were equally divided into experimental groups: normal control (NC, a collagenase-induced OA group, and OA groups treated with KBH-JP-040 (75, 100, and 150 mg/kg body weight and celecoxib (Cx, 100 mg/kg orally for 28 days. Treatment with KBH-JP-040 significantly attenuated inflammatory cytokines and matrix metalloproteinases (MMPs, suppressed the expression of IκBα, NF-κB, and JNK/p38 mitogen-activated protein (MAP kinase, and upregulated aggrecan and collagen type-II expression in rhIL-1α-stimulated chondrocytes. Furthermore, the serum and synovial levels of inflammatory cytokines of rabbits also decreased in the treatment groups when compared with the OA group. Improved magnetic resonance imaging and histopathological findings further confirmed the therapeutic efficacy of KBH-JP-040 against OA. In conclusion, these results indicate that KBH-JP-040 possesses chondroprotective effects, suppressing inflammation and MMPs, and downregulating IκBα, NF-κB, and JNK/p38 MAP kinase-signaling pathways. This might be a potential therapeutic candidate for OA treatment.

  5. 24 CFR 965.401 - Individually metered utilities.

    Science.gov (United States)

    2010-04-01

    ... URBAN DEVELOPMENT PHA-OWNED OR LEASED PROJECTS-GENERAL PROVISIONS Individual Metering of Utilities for Existing PHA-Owned Projects § 965.401 Individually metered utilities. (a) All utility service shall be... supplier or through the use of checkmeters, unless: (1) Individual metering is impractical, such as in the...

  6. Evaluation of uncertainties in the calibration of radiation survey meter

    International Nuclear Information System (INIS)

    Potiens, M.P.A.; Santos, G.P.

    2006-01-01

    In order to meet the requirements of ISO 17025, the quantification of the expanded uncertainties of experimental data in the calibration of survey meters must be carried out using well defined concepts, like those expressed in the 'ISO-Guide to the Expression of Uncertainty in Measurement'. The calibration procedure of gamma ray survey meters involves two values that have to get their uncertainties clearly known: measurements of the instrument under calibration and the conventional true values of a quantity. Considering the continuous improvement of the calibration methods and set-ups, it is necessary to evaluate periodically the involved uncertainties in the procedures. In this work it is shown how the measurement uncertainties of an individual calibration can be estimated and how it can be generalized to be valid for others radiation survey meters. (authors)

  7. Metering error quantification under voltage and current waveform distortion

    Science.gov (United States)

    Wang, Tao; Wang, Jia; Xie, Zhi; Zhang, Ran

    2017-09-01

    With integration of more and more renewable energies and distortion loads into power grid, the voltage and current waveform distortion results in metering error in the smart meters. Because of the negative effects on the metering accuracy and fairness, it is an important subject to study energy metering combined error. In this paper, after the comparing between metering theoretical value and real recorded value under different meter modes for linear and nonlinear loads, a quantification method of metering mode error is proposed under waveform distortion. Based on the metering and time-division multiplier principles, a quantification method of metering accuracy error is proposed also. Analyzing the mode error and accuracy error, a comprehensive error analysis method is presented which is suitable for new energy and nonlinear loads. The proposed method has been proved by simulation.

  8. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    Science.gov (United States)

    Darghouth, Naim Richard

    Net metering has become a widespread policy mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), allowing customers with PV systems to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption. Although net metering is one of the principal drivers for the residential PV market in the U.S., the academic literature on this policy has been sparse and this dissertation contributes to this emerging body of literature. This dissertation explores the linkages between the availability of net metering, wholesale electricity market conditions, retail rates, and the residential bill savings from behind-the-meter PV systems. First, I examine the value of the bill savings that customers receive under net metering and alternatives to net metering, and the associated role of retail rate design, based on current rates and a sample of approximately two hundred residential customers of California's two largest electric utilities. I find that the bill savings per kWh of PV electricity generated varies greatly, largely attributable to the increasing block structure of the California utilities' residential retail rates. I also find that net metering provides significantly greater bill savings than alternative compensation mechanisms based on avoided costs. However, retail electricity rates may shift as wholesale electricity market conditions change. I then investigate a potential change in market conditions -- increased solar PV penetrations -- on wholesale prices in the short-term based on the merit-order effect. This demonstrates the potential price effects of changes in market conditions, but also points to a number of methodological shortcomings of this method, motivating my usage of a long-term capacity investment and economic dispatch model to examine wholesale price effects of various wholesale market scenarios in the subsequent analysis. By developing

  9. Investigation of Separate Meter-In Separate Meter-Out Control Strategies for Systems with Over Centre Valves

    DEFF Research Database (Denmark)

    Pedersen, Henrik C.; Andersen, Torben Ole; Hansen, Rico Hjerm

    2010-01-01

    to overcome this problem, but it typically implies higher energy consumption and/or decreased control performance. With the development of robust sensors and new valve types with separate meter-in, separate meter-out control it is, however, possible to overcome these stability problems in a much more...... intelligent way, also adding increased functionality to the system. The focus of the current paper is therefore on investigation of different control strategies for Separate Meter-In Separate Meter-Out (SMISMO) control of general single axis hydraulic system with a differential cylinder and an over......-centre valve included. The paper first presents a general model of the system considered, which is experimentally verified. This is followed by a discussion of different control strategies and their implications. For each of the control strategies controllers are described, taking into account the dynamics...

  10. Smart meter deployment optimisation and its analysis for appliance load monitoring

    Directory of Open Access Journals (Sweden)

    Ahmed Shaharyar Khwaja

    2015-04-01

    Full Text Available In this study, the authors study the problem of smart meter deployment optimisation for appliance load monitoring, that is, to monitor a number of devices without any ambiguity using the minimum number of low-cost smart meters. The importance of this problem is due to the fact that the number of meters should be reduced to decrease the deployment cost, improve reliability and decrease congestion. In this way, in future, smart meters can provide additional information about the type and number of distinct devices connected, besides their normal functionalities concerned with providing overall energy measurements and their communication. The authors present two exact smart meter deployment optimisation algorithms, one based on exhaustive search and the other based on efficient implementation of the exhaustive search. They formulate the problem mathematically and present computational complexity analysis of their algorithms. Simulation scenarios show that for a typical number of home appliances, the efficient search method is significantly faster compared to the exhaustive search and can provide the same optimal solution. The authors also show the dependency of their method on the distribution of the load pattern that can potentially be in a typical household.

  11. Accuracy Improvement of Boron Meter Adopting New Fitting Function and Multi-Detector

    Directory of Open Access Journals (Sweden)

    Chidong Kong

    2016-12-01

    Full Text Available This paper introduces a boron meter with improved accuracy compared with other commercially available boron meters. Its design includes a new fitting function and a multi-detector. In pressurized water reactors (PWRs in Korea, many boron meters have been used to continuously monitor boron concentration in reactor coolant. However, it is difficult to use the boron meters in practice because the measurement uncertainty is high. For this reason, there has been a strong demand for improvement in their accuracy. In this work, a boron meter evaluation model was developed, and two approaches were considered to improve the boron meter accuracy: the first approach uses a new fitting function and the second approach uses a multi-detector. With the new fitting function, the boron concentration error was decreased from 3.30 ppm to 0.73 ppm. With the multi-detector, the count signals were contaminated with noise such as field measurement data, and analyses were repeated 1,000 times to obtain average and standard deviations of the boron concentration errors. Finally, using the new fitting formulation and multi-detector together, the average error was decreased from 5.95 ppm to 1.83 ppm and its standard deviation was decreased from 0.64 ppm to 0.26 ppm. This result represents a great improvement of the boron meter accuracy.

  12. Accuracy improvement of boron meter adopting new fitting function and multi-detector

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Chidong; Lee, Hyun Suk; Tak, Tae Woo; Lee, Deok Jung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of); KIm, Si Hwan; Lyou, Seok Jean [Users Incorporated Company, Hansin S-MECA, Daejeon (Korea, Republic of)

    2016-12-15

    This paper introduces a boron meter with improved accuracy compared with other commercially available boron meters. Its design includes a new fitting function and a multi-detector. In pressurized water reactors (PWRs) in Korea, many boron meters have been used to continuously monitor boron concentration in reactor coolant. However, it is difficult to use the boron meters in practice because the measurement uncertainty is high. For this reason, there has been a strong demand for improvement in their accuracy. In this work, a boron meter evaluation model was developed, and two approaches were considered to improve the boron meter accuracy: the first approach uses a new fitting function and the second approach uses a multi-detector. With the new fitting function, the boron concentration error was decreased from 3.30 ppm to 0.73 ppm. With the multi-detector, the count signals were contaminated with noise such as field measurement data, and analyses were repeated 1,000 times to obtain average and standard deviations of the boron concentration errors. Finally, using the new fitting formulation and multi-detector together, the average error was decreased from 5.95 ppm to 1.83 ppm and its standard deviation was decreased from 0.64 ppm to 0.26 ppm. This result represents a great improvement of the boron meter accuracy.

  13. 20-meter underwater wireless optical communication link with 1.5 Gbps data rate.

    Science.gov (United States)

    Shen, Chao; Guo, Yujian; Oubei, Hassan M; Ng, Tien Khee; Liu, Guangyu; Park, Ki-Hong; Ho, Kang-Ting; Alouini, Mohamed-Slim; Ooi, Boon S

    2016-10-31

    The video streaming, data transmission, and remote control in underwater call for high speed (Gbps) communication link with a long channel length (~10 meters). We present a compact and low power consumption underwater wireless optical communication (UWOC) system utilizing a 450-nm laser diode (LD) and a Si avalanche photodetector. With the LD operating at a driving current of 80 mA with an optical power of 51.3 mW, we demonstrated a high-speed UWOC link offering a data rate up to 2 Gbps over a 12-meter-long, and 1.5 Gbps over a record 20-meter-long underwater channel. The measured bit-error rate (BER) are 2.8 × 10-5, and 3.0 × 10-3, respectively, which pass well the forward error correction (FEC) criterion.

  14. FibroMeters: a family of blood tests for liver fibrosis.

    Science.gov (United States)

    Calès, P; Boursier, J; Oberti, F; Hubert, I; Gallois, Y; Rousselet, M-C; Dib, N; Moal, V; Macchi, L; Chevailler, A; Michalak, S; Hunault, G; Chaigneau, J; Sawadogo, A; Lunel, F

    2008-09-01

    FibroMeters are blood tests for liver fibrosis with several specificities: two main diagnostic targets (fibrosis stage and area of fibrosis); adaptation to specific causes; and results confirmed by an expert system. Thus, FibroMeters comprise six different tests: one for staging and one for quantitation of liver fibrosis in each of the three main causes of chronic liver disease-chronic viral hepatitis, alcoholic liver disease (ALD) and non-alcoholic fatty liver disease (NAFLD). FibroMeters display a high overall diagnostic accuracy and are the only tests to correctly classify 100% of HCV patients without fibrosis or with cirrhosis. They have 90% predictive values in a higher proportion of patients than with other usual blood tests. A 90% correct classification is available in 100% of HCV patients with the following reliable diagnostic intervals: F0/1, F1/2, F2+/-1, F3+/-1. In real-life conditions, the reproducibility of FibroMeters is higher than that of liver biopsy or ultrasonographic elastometry. FibroMeters are robust tests with the most stable diagnostic performance across different centers. Optional tests are also available, such as a specific one for cirrhosis, which has a diagnostic accuracy of 93.0% (AUROC: 0.92) and a 100% positive predictive value for diagnosis of HCV cirrhosis. Determination by FibroMeters of the area of fibrosis - the only direct, non-invasive, quantitative measurement of liver fibrosis - are especially useful for following-up cirrhosis as it correlates well with clinical events. FibroMeters are also very accurate in HVB or HIV-HCV co-infected patients. The tests specific for ALD and NAFLD also have a high diagnostic accuracy (AUROCs: 0.96 and 0.94, respectively, for significant fibrosis).

  15. Impact on Diabetes Self-Management and Glycemic Control of a New Color-Based SMBG Meter.

    Science.gov (United States)

    Schnell, Oliver; Klausmann, Gerd; Gutschek, Bettina; Garcia-Verdugo, Rosa Maria; Hummel, Michael

    2017-11-01

    Self-monitoring of blood glucose (SMBG) is a key pillar of personal diabetes management. The objective of this observational study was to analyze diabetes self-management (DSM) and glycemic outcomes before and during system implementation in real-life settings of a blood glucose meter system with a color-coded display of glucose levels, which helps identify out-of-range levels. A total of 193 insulin-treated diabetes patients (11% T1DM; 55% male, age 60 ± 4 years, mean diabetes duration 14 ± 9 years, HbA1c 8.68 ± 1.2%) were enrolled into the study. Both the Diabetes Self-Management Questionnaire (DSMQ) and glycemic control were analyzed at baseline and 3 and 6 months after study initiation. DSMQ general perception improved significantly by the end of the study period ("Sum Scale," P meter resulted in improved glycemic control, as shown by mean HbA1c levels, which decreased from 8.68 ± 1.2% at baseline to 8.13 ± 1.02% after 3 months ( P meter not only leads to an improvement in metabolic control, but also is associated with a significant improvement in diabetes management.

  16. Synthetic Fischer-Tropsch (FT) JP-5/JP-8 Aviation Turbine Fuel Elastomer Compatibility

    National Research Council Canada - National Science Library

    Muzzell, Pat; Stavinoha, Leo; Chapin, Rebecca

    2005-01-01

    ... to seal performance may arise, possibly leading to fuel leakage. The key objective of this study was to compare and contrast the material compatibility of nitrile coupons and O-rings with selected petroleum-derived fuels, Fisher-Tropsch (FT...

  17. Educational Electrical Appliance Power Meter and Logger

    Science.gov (United States)

    Nunn, John

    2013-01-01

    The principles behind two different designs of inductive power meter are presented. They both make use of the microphone input of a computer which, together with a custom-written program, can record the instantaneous power of a domestic electrical appliance. The device can be built quickly and can be calibrated with reference to a known power…

  18. Evaluation of a new portable glucose meter designed for the use in cats.

    Science.gov (United States)

    Zini, E; Moretti, S; Tschuor, F; Reusch, C E

    2009-09-01

    Portable blood glucose meters (PBGMs) are useful in the management of diabetes mellitus in cats. In the present study we compared the performance of two PBGMs: the AlphaTRAK (Abbott Animal Health, Maidenhead, England) specifically developed for dogs and cats, and the Ascensia ELITE (Bayer HealthCare, Zurich, Switzerland) developed for humans. Quality parameters, including precision and accuracy, were better for the AlphaTRAK meter compared to Ascensia ELITE. While the AlphaTRAK meter results did not differ from the reference method, results from the Ascensia ELITE were significantly (Pblood glucose levels in cats.

  19. Smart Metering System for Microgrids

    DEFF Research Database (Denmark)

    Palacios-Garcia, Emilio; Guan, Yajuan; Savaghebi, Mehdi

    2015-01-01

    suppliers, but they can also play a big role in the control of the Microgrid since the recorded power and energy profiles can be integrated in energy management systems (EMS). In addition, basic power quality (PQ) disturbance can de detected and reported by some advanced metering systems. Thus, this paper...... will expose an example of Smart Meters integration in a Microgrid scenario, which is the Intelligent Microgrid Lab of Aalborg University (AAU). To do this, first the installation available in the Microgrid Lab will be introduced. Then, three different test scenarios and their respective results...... will be presented, regarding the capabilities of this system and the advantages of integration the Smart Meters information in the Microgrid control....

  20. Low Cost Digital Vibration Meter.

    Science.gov (United States)

    Payne, W Vance; Geist, Jon

    2007-01-01

    This report describes the development of a low cost, digital Micro Electro Mechanical System (MEMS) vibration meter that reports an approximation to the RMS acceleration of the vibration to which the vibration meter is subjected. The major mechanical element of this vibration meter is a cantilever beam, which is on the order of 500 µm in length, with a piezoresistor deposited at its base. Vibration of the device in the plane perpendicular to the cantilever beam causes it to bend, which produces a measurable change in the resistance of a piezoresistor. These changes in resistance along with a unique signal-processing scheme are used to determine an approximation to the RMS acceleration sensed by the device.

  1. Approximation of the breast height diameter distribution of two-cohort stands by mixture models III Kernel density estimators vs mixture models

    Science.gov (United States)

    Rafal Podlaski; Francis A. Roesch

    2014-01-01

    Two-component mixtures of either the Weibull distribution or the gamma distribution and the kernel density estimator were used for describing the diameter at breast height (dbh) empirical distributions of two-cohort stands. The data consisted of study plots from the Å wietokrzyski National Park (central Poland) and areas close to and including the North Carolina section...

  2. Robust Meter Network for Water Distribution Pipe Burst Detection

    OpenAIRE

    Donghwi Jung; Joong Hoon Kim

    2017-01-01

    A meter network is a set of meters installed throughout a water distribution system to measure system variables, such as the pipe flow rate and pressure. In the current hyper-connected world, meter networks are being exposed to meter failure conditions, such as malfunction of the meter’s physical system and communication system failure. Therefore, a meter network’s robustness should be secured for reliable provision of informative meter data. This paper introduces a multi-objective optimal me...

  3. JP-HHT phenotype in Danish patients with SMAD4 mutations

    DEFF Research Database (Denmark)

    Jelsig, A M; Tørring, P M; Kjeldsen, A D

    2016-01-01

    Patients with germline mutations in SMAD4 can present symptoms of both juvenile polyposis syndrome (JPS) and hereditary hemorrhagic telangiectasia (HHT): the JP-HHT syndrome. The complete phenotypic picture of this syndrome is only just emerging. We describe the clinical characteristics of 14......, aortopathy and family history were noted. We detected 14 patients with SMAD4 mutations. All patients had polyps removed and 11 of 14 fulfilled the diagnostic criteria for JPS. Eight patients were screened for HHT-symptoms and seven of these fulfilled the Curaçao criteria. One patient had aortic root dilation...

  4. Versatile operation meter for nuclear information

    International Nuclear Information System (INIS)

    Huang Yong; Xiao Yabin; Wang Shuyuan; Shu Jingfang; Di Shaoliang; Wu Hongbin

    1995-01-01

    This paper states a low-cost, small-volume, multi-function, reproducible and new model intelligent nuclear electronic meter. It's hardware and Software were detailed and the 137 Cs spectrum with this meter was presented

  5. Smart metering - new possibilities for energy distribution in the mass customer sector; Smart Metering - neue Moeglichkeiten fuer den Energievertrieb im Massenkundenbereich

    Energy Technology Data Exchange (ETDEWEB)

    Haller, T. [Simon-Kucher aand Partners GmbH, Wien (Austria); Hoffmann, S.O.; Rentschler, M.D. [Simon-Kucher and Partners Strategy and Marketing Consultants GmbH, Bonn (Germany)

    2008-06-15

    As a result of the liberalisation of gas and electricity metering procedures energy suppliers are more and more turning their attention to innovative and intelligent metering techniques. Smart Metering allows energy suppliers to improve their metering processes while at the same time responding better to their customers' needs. These developments are also opening up new sales opportunities because intelligent meters facilitate the launch of new products in the mass customer sector. There is therefore much in favour of looking at this topic in greater detail.

  6. Massive stars dying alone: Extremely remote environments of SN2009ip and SN2010jp

    Science.gov (United States)

    Smith, Nathan

    2014-10-01

    We propose an imaging study of the astonishingly remote environments of two recent supernovae (SNe): SN2009ip and SN2010jp. Both were unusual Type IIn explosions that crashed into dense circumstellar material (CSM) ejected by the star shortly before explosion. The favored progenitors of these SNe are very massive luminous blue variable (LBV) stars. In fact, SN2009ip presents an extraordinay case where the LBV-like progenitor was actually detected directly in archival HST data, and where we obtained spectra and photometry for numerous pre-SN eruptions. No other SN has this treasure trove of detailed information about the progenitor (not even SN1987A). SN2010jp represents a possible collapsar-powered event, since it showed evidence of a fast bipolar jet in spectra and a low 56Ni mass; this would be an analog of the black-hole forming explosions that cause gamma ray bursts, but where the relativistic jet is damped by a residual H envelope on the star. In both cases, the only viable models for these SNe involve extremely massive (initial masses of 40-100 Msun) progenitor stars. This seems at odds with their extremely remote environments in the far outskirts of their host galaxies, with no detected evidence for an underlying massive star population in ground-based data (nor in the single shallow WFPC2/F606W image of SN2009ip). Here we propose deep UV HST images to search for any mid/late O-type stars nearby, deep red images to detect any red supergiants, and an H-alpha image to search for any evidence of ongoing star formation in the vicinity. These observations will place important and demanding constraints on the initial masses and ages of these progenitors.

  7. Inferring diameters of spheres and cylinders using interstitial water.

    Science.gov (United States)

    Herrera, Sheryl L; Mercredi, Morgan E; Buist, Richard; Martin, Melanie

    2018-06-04

    Most early methods to infer axon diameter distributions using magnetic resonance imaging (MRI) used single diffusion encoding sequences such as pulsed gradient spin echo (SE) and are thus sensitive to axons of diameters > 5 μm. We previously simulated oscillating gradient (OG) SE sequences for diffusion spectroscopy to study smaller axons including the majority constituting cortical connections. That study suggested the model of constant extra-axonal diffusion breaks down at OG accessible frequencies. In this study we present data from phantoms to test a time-varying interstitial apparent diffusion coefficient. Diffusion spectra were measured in four samples from water packed around beads of diameters 3, 6 and 10 μm; and 151 μm diameter tubes. Surface-to-volume ratios, and diameters were inferred. The bead pore radii estimates were 0.60±0.08 μm, 0.54±0.06 μm and 1.0±0.1 μm corresponding to bead diameters ranging from 2.9±0.4 μm to 5.3±0.7 μm, 2.6±0.3 μm to 4.8±0.6 μm, and 4.9±0.7 μm to 9±1 μm. The tube surface-to-volume ratio estimate was 0.06±0.02 μm -1 corresponding to a tube diameter of 180±70 μm. Interstitial models with OG inferred 3-10 μm bead diameters from 0.54±0.06 μm to 1.0±0.1 μm pore radii and 151 μm tube diameters from 0.06±0.02 μm -1 surface-to-volume ratios.

  8. Radio-controlled automatic gas meter-reading system; Releve automatique de compteur par radio

    Energy Technology Data Exchange (ETDEWEB)

    Yasui, M. [Osaka Gas Co., Ltd (Japan); Ishikawa, K.; Fujiwara, J. [Tokyo Gas Co., Ltd. (Japan); Ichihashi, T. [Toho Gas Co., Ltd. (Japan)

    2000-07-01

    In Japan, an automatic gas meter-reading system is in operation, also incorporating the functions of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff. This system has been realized by linking microcomputer-controlled gas meters(It's called 'Intelligent gas mater') equipped with automatic shutoff mechanism to the gas utility company operation center via communication lines. While the present system uses cable communication lines, we of Tokyo Gas Co., Ltd., Osaka Gas Co., Ltd. and Toho Gas Co., Ltd., have jointly developed a new system based on radio communication. This paper introduces this new system. While radio-controlled meter-reading systems are used in many countries around the world solely for automatic meter reading, our recently developed system is also capable of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff, thanks to its almost real-time two-way communication function. The new system can serve for a period of ten years without recharging. It is also characterized by its applicability as different systems according to purposes: 1) conventional automatic meter-reading system (terminal network control unit or T-NCU), 2) large-scale radio-controlled meter-reading system, and 3) portable terminal-type radio-controlled meter-reading system. (authors)

  9. Proceedings of the 2006 smart metering conference and expo

    International Nuclear Information System (INIS)

    2006-01-01

    Ontario's smart metering program was launched as part of a general demand response management strategy to improve energy conservation in the province. Smart metering will help consumers to control their electricity bills through conservation and demand response, and will allow consumers to better manage their energy consumption and use it more effectively during cheaper, off-peak times of day. Smart metering systems measure how much electricity a customer uses on an hourly basis, and data is transferred daily to local electricity distributors. Toronto Hydro will have close to 200,000 smart meters installed by the end of 2006. By 2010, Toronto will be North America's largest urban centre to have made the full transition to smart metering technology across its entire base. This conference provided an update of Toronto Hydro's smart metering project, as well as details of their demand response program. Presentations were given by a variety of experts in information technology as well as electric power industry leaders North American demand and response metering strategies were reviewed, as well as various initiatives in advanced metering infrastructure (AMI). Security risks associated with smart metering environments were reviewed. An evaluation of the current regulatory environment was presented along with a discussion of smart metering standards and compatibility issues. New metering technologies were presented as well as various associated demand side management tools. Smart metering pilot programs and initiatives were discussed, and best practices in smart metering were evaluated. Twenty-nine presentations were given at the conference, 13 of which have been indexed separately for inclusion in this database. refs., tabs., figs

  10. Multi-diameter pigging: factors affecting the design and selection of pigging tools for multi-diameter pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, Karl [Pipeline Engineering and Supply Co. Ltd., Richmond, NY (United States)

    2009-07-01

    This paper will consider the process involved in pigging tool selection for pipelines with two or more significant internal diameters which require pigging tools capable of negotiating the different internal diameters whilst also carrying out the necessary pipeline cleaning operation. The paper will include an analysis of pipeline features that affect pigging tool selection and then go on to look at other variables that determine the pigging tool design; this will include a step by step guide outlining how the tool is designed, the development of prototype pigs and the importance of testing and validation prior to final deployment in operational pigging programmes. (author)

  11. Fabrication of high-aspect ratio SU-8 micropillar arrays

    DEFF Research Database (Denmark)

    Amato, Letizia; Keller, Stephan S.; Heiskanen, Arto

    2012-01-01

    to the resolution limit of photolithography. This paper describes process optimization for the fabrication of dense SU-8 micropillar arrays (2.5μm spacing) with nominal height ⩾20μm and nominal diameter ⩽2.5μm (AR ⩾8). Two approaches, differing in temperature, ramping rate and duration of the baking steps were...... compared as part of the photolithographic processing, in order to evaluate the effect of baking on the pattern resolution. Additionally, during the post-processing, supercritical point drying and hard baking were introduced yielding pillars with diameter 1.8μm, AR=11 and an improved temporal stability....

  12. Bone tunnel diameter measured with CT after anterior cruciate ligament reconstruction using double-bundle auto-hamstring tendors: Clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Soo Jeong; Yoon, Young Cheol; Bae, So Young; Wang, Joon Ho [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-12-15

    To evaluate the correlation between bone tunnel diameter after anterior cruciate ligament (ACL) reconstruction measured by computed tomography (CT) using multiplanar reconstruction (MPR) and stability or clinical scores. Forty-seven patients (41 men and 6 women, mean age: 34 years) who had undergone ACL reconstruction with the double bundle technique using auto-hamstring graft and had subsequently received CT scans immediately after the surgery (T1: range, 1-4 days, mean, 2.5 days) and at a later time (T2: range, 297-644 days, mean, 410.4 days) were enrolled in this study. The diameter of each tunnel (two femoral and two tibial) at both T1 and T2 were independently measured using MPR technique by two radiologists. Stability and clinical scores were evaluated with a KT-2000 arthrometer, International Knee Documentation Committee objective scores, and the Lysholm score. Statistical analysis of the correlation between the diameter at T2 or the interval diameter change ratio ([T2 - T1] / T1) and clinical scores or stability was investigated. The tibial bone tunnels for the anteromedial bundles were significantly widened at T2 compared with T1 (observer 1, 0.578 mm to 0.698 mm, p value of < 0.001; observer 2, 0.581 mm to 0.707 mm, p value of < 0.001). There was no significant correlation between the diameter at T2 and stability or clinical scores and between the interval change ratio ([T2 - T1] / T1) and stability or clinical scores (corrected p values for all were 1.0). Intraobserver agreement for measurements was excellent (> 0.8) for both observers. Interobserver agreement for measurement was excellent (> 0.8) except for the most distal portion of the femoral bone tunnel for anterior medial bundle in immediate postoperative CT, which showed moderate agreement (concordance correlation coefficient = 0.6311).Neither the diameter nor its change ratio during interval follow-up is correlated with stability or clinical scores.

  13. Bone tunnel diameter measured with CT after anterior cruciate ligament reconstruction using double-bundle auto-hamstring tendors: Clinical implications

    International Nuclear Information System (INIS)

    Yoon, Soo Jeong; Yoon, Young Cheol; Bae, So Young; Wang, Joon Ho

    2015-01-01

    To evaluate the correlation between bone tunnel diameter after anterior cruciate ligament (ACL) reconstruction measured by computed tomography (CT) using multiplanar reconstruction (MPR) and stability or clinical scores. Forty-seven patients (41 men and 6 women, mean age: 34 years) who had undergone ACL reconstruction with the double bundle technique using auto-hamstring graft and had subsequently received CT scans immediately after the surgery (T1: range, 1-4 days, mean, 2.5 days) and at a later time (T2: range, 297-644 days, mean, 410.4 days) were enrolled in this study. The diameter of each tunnel (two femoral and two tibial) at both T1 and T2 were independently measured using MPR technique by two radiologists. Stability and clinical scores were evaluated with a KT-2000 arthrometer, International Knee Documentation Committee objective scores, and the Lysholm score. Statistical analysis of the correlation between the diameter at T2 or the interval diameter change ratio ([T2 - T1] / T1) and clinical scores or stability was investigated. The tibial bone tunnels for the anteromedial bundles were significantly widened at T2 compared with T1 (observer 1, 0.578 mm to 0.698 mm, p value of < 0.001; observer 2, 0.581 mm to 0.707 mm, p value of < 0.001). There was no significant correlation between the diameter at T2 and stability or clinical scores and between the interval change ratio ([T2 - T1] / T1) and stability or clinical scores (corrected p values for all were 1.0). Intraobserver agreement for measurements was excellent (> 0.8) for both observers. Interobserver agreement for measurement was excellent (> 0.8) except for the most distal portion of the femoral bone tunnel for anterior medial bundle in immediate postoperative CT, which showed moderate agreement (concordance correlation coefficient = 0.6311).Neither the diameter nor its change ratio during interval follow-up is correlated with stability or clinical scores

  14. Digital reactor period meter type of NSSG-7

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W

    1981-01-01

    The paper presents the idea and electronic circuits of the Digital Reactor Period Meter. The instrument consists of a neutron ionisation chamber, the amplifier logarithming the output chamber current, the circuit taking two samples of the log amplifier output signal and subtracting them, the analog -to -digital dividing circuit and the scaler providing the final information of the reactor period value in seconds and in the digital form. Besides it, the instrument produces the acoustic signal in the case, when the rise-time of neutron flux exceeds the permitted value. The untypical construction of the reactor period meter has been developed to obtain both good measurement accuracy and the resistance against the electromagnetic background pulses interfering with the measuring process. The applied measuring system has been patented.

  15. Arduino based radiation survey meter

    International Nuclear Information System (INIS)

    Rahman, Nur Aira Abd; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee; Muzakkir, Amir

    2016-01-01

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr −1 ). Conversion factor (CF) value for conversion of CPM to μSvhr −1 determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr

  16. Usefulness of real time PCR for the differentiation and quantification of 652 and JP2 Actinobacillus actinomycetemcomitans genotypes in dental plaque and saliva

    Directory of Open Access Journals (Sweden)

    Piras Vincenzo

    2006-06-01

    Full Text Available Abstract Background The aim of our study is to describe a fast molecular method, able to distinguish and quantize the two different genotypes (652 and JP2 of an important periodontal pathogen: Actinobacillus actinomycetemcomitans. The two genotypes show differences in the expression of an important pathogenic factor: the leukotoxin (ltx. In order to evidence this, we performed a real time PCR procedure on the ltx operon, able to recognize Aa clinical isolates with different leukotoxic potentials. Methods The specificity of the method was confirmed in subgingival plaque and saliva specimens collected from eighty-one Italian (Sardinian subjects with a mean age of 43.9, fifty five (68 % of whom had various clinical forms of periodontal disease. Results This procedure showed a good sensitivity and a high linear dynamic range of quantization (107-102 cells/ml for all genotypes and a good correlation factor (R2 = 0.97–0.98. Compared with traditional cultural methods, this real time PCR procedure is more sensitive; in fact in two subgingival plaque and two positive saliva specimens Aa was only detected with the molecular method. Conclusion A low number of Sardinian patients was found positive for Aa infections in the oral cavity, (just 10 positive periodontal cases out of 81 and two of these were also saliva positive. The highly leukotoxic JP2 strain was the most representative (60 % of the positive specimens; the samples from periodontal pockets and from saliva showed some ltx genotype for the same patient. Our experience suggests that this approach is suitable for a rapid and complete laboratory diagnosis for Aa infection.

  17. Energy metering, management and accounting; Comptage, gestion, et comptabilite de l`energie

    Energy Technology Data Exchange (ETDEWEB)

    Foucherand, P. [Agence de l`environnement et de la maitrise de l`energie, Rhone-Alpes (France)

    1996-12-31

    The activities of the French Energy Conservation Agency (ADEME) in the field of energy management and conservation through energy metering in industrial plants, and more especially in mechanical and metal industries, are presented. Audit and diagnostic procedures and information/awareness measures are presented and discussed with the example of a regional program, and two operations conducted in a mechanical industrial plant and a foundry where metering systems were installed

  18. Variations the diameter tip of electrode on the resistance spot welding using electrode Cu on worksheet Fe

    Science.gov (United States)

    Baskoro, A. S.; Sugeng, S.; Sifa, Agus; Badruzzaman; Endramawan, Tito

    2018-04-01

    Resistance Spot Weld (RSW) is a welding technology which plays an important role that is often used in industry in large manufacturing industries, especially in the automotive sector, some of the parameters are affecting the welding process that give impact in the weld quality, diameter tip important impact on the resistance spot welding, This study can be categorized as experimental study by using Electrode material such as Cu and Fe Worksheet Materials, with a material thickness of 1 mm,0,8 mm, and 0,6 mm on each worksheet, and the large diameter of tip electrode (5√t) depend on the thickness of worksheet. Testing the material in the electrode and the worksheet by testing the composition and tensile test, and the hardness of the material used are to know the material used certainly. The result of the welding process was done by using the parameters voltage of 8KV, with a duty cycle of 50% using a variation of the time 8s-10s, and variations the electrode tip diameter that are affected by the thickness of the worksheet 5\\sqrt{t}, plate thickness used 1 mm, 0,8 mm and 0,6 mm, so that the electrodes was used to a thickness of 1 mm diameter tip electrode 5 mm, thickness 0,8 mm with an electrode tip diameter 4,5 mm and a thickness 0,6 mm with an electrode diameter of 4 mm, with current welding parameter 8kVA, and variations in holding time 10s, 9s and 8s 50% duty cycle, then testing welds with the standard shear test refers ASTM A370-2012 with more results to a thickness of 0,6 has the ability to withstand greater load on the holding time 8s and 9s, 10s, to a thickness 0,8 mm and 1 mm shear test results demonstrate the ability to withstand loads on the holding time of 10s and 9s have a greater ability than 8s on worksheet that has thickness 1 mm at a holding time of 10s, and then Maximum shear test averaging of 36,41 N at a worksheet with a thickness of 0,8 mm (diameter tip 4,5 mm) at a holding time of 8s and a mean minimum shear stress of 23,73 N at worksheet that

  19. A Framework for Reliable Reception of Wireless Metering Data using Protocol Side Information

    DEFF Research Database (Denmark)

    Melchior Jacobsen, Rasmus; Popovski, Petar

    2013-01-01

    the deterministic protocol structure to obtain side information and group the packets from the same meter. We derive the probability of falsely pairing packets from different senders in the simple case of no channel errors, and show through simulation and data from an experimental deployment the probability...... of false pairing with channel errors. The pairing is an essential step towards recovery of metering data from as many as possible meters under harsh channel conditions. From the experiment we find that more than 15% of all conducted pairings are between two erroneous packets, which sets an upper bound...

  20. Inadequate peak expiratory flow meter characteristics detected by a computerised explosive decompression device

    DEFF Research Database (Denmark)

    Miller, M.R.; Atkins, P.R.; Pedersen, O.F.

    2003-01-01

    Methods: The dynamic response of mini-Wright (MW), Vitalograph (V), TruZone (TZ), MultiSpiro (MS) and pneumotachograph (PT) flow meters was tested by delivering two differently shaped flow-time profiles from a computer controlled explosive decompression device fitted with a fast response solenoid.......1) and 257 (39.2), respectively, and at ≈200 l/min they were 51 (23.9) and 1 (0.5). All the meters met ATS accuracy requirements when tested with their waveforms. Conclusions: An improved method for testing the dynamic response of flow meters detects marked overshoot (underdamping) of TZ and MS responses...

  1. Automatic ranging circuit for a digital panel meter

    International Nuclear Information System (INIS)

    Mueller, T.R.; Ross, H.H.

    1976-01-01

    This invention relates to a range changing circuit that operates in conjunction with a digital panel meter of fixed sensitivity. The circuit decodes the output of the panel meter and uses that information to change the gain of an input amplifier to the panel meter in order to ensure that the maximum number of significant figures is always displayed in the meter. The circuit monitors five conditions in the meter and responds to any of four combinations of these conditions by means of logic elements to carry out the function of the circuit. The system was designed for readout of a fluorescence analyzer for uranium analysis

  2. Design and construction of two 10.8 T.m superconducting beam bending magnets

    International Nuclear Information System (INIS)

    Dow, P.; Kesseler, G.

    1978-01-01

    Constructional details are given of two superconducting beam bending magnets built at CERN in 1975-77. Each magnet unit has a bending power of 10.8 T.m at the nominal current of 700 A, corresponding to a central induction of 4.75 T in a cold bore of 74 mm diameter. An 'intersecting-ellipses' coil configuration is approximated by 36 horizontally wound racetrack layers of rectangular cross-section with 90 0 bends at the coil ends. A cold-iron magnetic shield serves, in addition, as retaining structure for the electromagnetic forces. The vacuum-insulated liquid helium vessel is surrounded by a radiation shield cooled by helium boil-off gas and supported by a fibre-glass/ stainless steel suspension system. The cryogenic losses of each magnet cryostat are approximately 4 W excluding transfer losses. After successful tests the magnets were placed in a particle beam where they have been regularly operated on automatic control for about one year. (Auth.)

  3. EU data protection and smart metering. Legal boundary conditions; EU-Datenschutz und Smart Metering. Rechtliche Rahmenbedingungen

    Energy Technology Data Exchange (ETDEWEB)

    Hladjk, Joerg [Praxisgruppe European Data Protection and Privacy, Hunton and Williams, Bruessel (Belgium)

    2011-07-01

    With the introduction of smart metering, the problem of data protection arises. The independent Article 29 Data Protection Group of the European Commission drew up an expert opinion with the intention of explaining the applicable EU data protection regulations for the smart metering technology in the power supply sector. (orig.)

  4. Pratt & Whitney aircraft nuclear J-8 turbojet engine performance variation with radiator diameter

    International Nuclear Information System (INIS)

    Larson, John W.

    1960-01-01

    The variation of engine performance with liquid metal radiator diameter and flight altitude has been estimated for both the 1600F NaK and 1800F NaK radiators at Mach 0.6 and hot day atmospheric conditions. The net thrust, air flow and reactor power is presented in 3 figures for the Pratt & Whitney Aircraft J-58 engine with the 1600F NaK radiator. The net thrust, air flow and reactor power for the 1800F NaK radiator are also presented in figures.

  5. Wind tunnel tests on a one-foot diameter SR-7L propfan model

    Science.gov (United States)

    Aljabri, Abdullah S.

    1987-01-01

    Wind tunnel tests have been conducted on a one-foot diameter model of the SR-7L propfan in the Langley 16-Foot and 4 x 7 Meter Wind Tunnels as part of the Propfan Test Assessment (PTA) Program. The model propfan was sized to be used on a 1/9-scale model of the PTA testbed aircraft. The model propeller was tested in isolation and wing-mounted on the aircraft configuration at various Mach numbers and blade pitch angles. Agreement between data obtained from these tests and data from Hamilton Standard validate that the 1/9-scale propeller accurately simulates the aerodynamics of the SR-7L propfan. Predictions from an analytical computer program are presented and show good agreement with the experimental data.

  6. Your Glucose Meter

    Science.gov (United States)

    ... Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco ... 164KB) En Español Basic Facts 7 Tips for Testing Your Blood Sugar and Caring for Your Meter ...

  7. Arduino based radiation survey meter

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Nur Aira Abd, E-mail: nur-aira@nm.gov.my; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee [Malaysian Nuclear Agency, 43000, Bangi, Selangor (Malaysia); Muzakkir, Amir [Sinaran Utama Teknologi Sdn Bhd, 43650, Bandar Baru Bangi, Selangor (Malaysia)

    2016-01-22

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr{sup −1}). Conversion factor (CF) value for conversion of CPM to μSvhr{sup −1} determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr.

  8. Determination of moisture content in hard coals using microwave meter

    International Nuclear Information System (INIS)

    Chrusciel, E.; Kopec, M.; Turek, B.

    1989-01-01

    The results of hard-coal moisture-content measurements, performed with the aid of the ZAM-WILMER microwave meter are presented. Over 80 ground coal samples, weighing 1.5 kg (approx.) each, were examined. The moisture content values ranged from 0 to 15 wt%, with the mean standard error being equal to 0.8 wt%. 5 refs., 2 figs., 1 tab. (author)

  9. Pupil diameter, working distance and illumination during habitual tasks. Implications for simultaneous vision contact lenses for presbyopia.

    Science.gov (United States)

    Cardona, Genís; López, Sílvia

    2016-01-01

    To determine working distance, pupil diameter and illumination in real life conditions in a sample of presbyopic participants performing habitual tasks. A total of 59 presbyopic subjects (aged between 45 and 63 years) with different occupational backgrounds participated in the study. Participants were first interviewed regarding their habitual tasks with the aid of an ad hoc questionnaire, following which in-office photopic and mesopic pupil diameter was determined. Pupil diameter was also evaluated while participants conducted each of the self-reported habitual tasks by taking a photograph, which was later submitted to image analysis. In addition, working distance was determined with a measuring tape and the illumination that reached the pupil during each of the different tasks was measured, in lux, with a light meter. The four most common habitual tasks were computer use, reading, sewing and sports. A high intersubject variability was found in pupil diameter, working distance and illumination conditions while conducting the same task. Statistically significant differences were found between the in-office measured photopic and mesopic pupil diameters and those obtained while participants were conducting their habitual tasks in real life conditions (all p<0.001). Potential multifocal contact lens users may present with different ages, different jobs or hobbies and different preferences regarding lighting conditions and working distances. This results in different pupil size, even within the same task. This information may be critical when selecting a particular lens design and add power. Eye care practitioners are therefore advised to assess pupil diameter in real life conditions. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  10. How today's USM diagnostics solve metering problems[Ultrasonic meters

    Energy Technology Data Exchange (ETDEWEB)

    Lansing, John

    2005-07-01

    This paper discusses both basic and advanced diagnostic features of gas ultrasonic meters (USM), and how capabilities built into today's electronics can identify problems that often may not have been identified in the past. It primarily discusses fiscal-quality, multi-path USMs and does not cover issues that may be different with non-fiscal meters. Although USMs basically work the same, the diagnostics for each manufacturer does vary. All brands provide basic features as discussed in AGA 9. However, some provide advanced features that can be used to help identify issues such as blocked flow conditioners and gas compositional errors. This paper is based upon the Daniel USM design and the information presented here may or may not be applicable to other manufacturers. (author) (tk)

  11. Information security of remote-reading energy meters

    International Nuclear Information System (INIS)

    Jacobson, J.

    1994-01-01

    This report presents basic concepts within the field of IT security. The ITSEC security and the ITSEM methods given by the European Community are used as a base. The EC INFOSEC research programme has included the project 'PER DOMUM' which focuses on remote reading of energy meters. The project is a co-operation between TACS (U.K.), GPP (Germany), CESI (Italy) and ENEL (Italy). SP has during the spring and summer of 1994 participated in the concluding of the project. Threats, security functions and security mechanisms are given for remote reading of energy meters. All of the listed functions and mechanisms do not origin from the 'PER DOMUM' project, but are the experiences of SP. The security evaluation is explained in two ways. One description of the required by ITSEM is given. Another description is given of which deliverables are required to perform the evaluation

  12. De Minimis Thresholds for Federal Building Metering Appropriateness

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, Jordan W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-31

    The U.S. Department of Energy (DOE) is required by statute and Presidential Memorandum to establish guidelines for agencies to meter their Federal buildings for energy (electricity, natural gas, and steam) and water. See 42 U.S.C. § 8253(e). DOE issued guidance in February 2006 on the installation of electric meters in Federal buildings. A recent update to the 2006 guidance accounts for more current metering practices within the Federal Government. The updated metering guidance specifies that all Federal buildings shall be considered “appropriate” for energy or water metering unless identified for potential exclusion. In developing the updated guidance to carry out the statue, Congress also directed DOE to (among other things) establish exclusions from the metering requirements based on the de minimis quantity of energy use of a Federal building, industrial process, or structure. This paper discusses the method used to identify de minimis values.

  13. Water metering in England and Wales

    Directory of Open Access Journals (Sweden)

    David Zetland

    2016-02-01

    Full Text Available The transformation of water services that began with the privatisation of water companies in 1989 extended to households with the implementation of water metering. Meters 'privatised' water and the cost of provision by allocating to individual households costs that had previously been shared within the community. This (ongoing conversion of common pool to private good has mostly improved economic, environmental and social impacts, but the potential burden of metering on poorer households has slowed the transition. Stronger anti-poverty programmes would be better at addressing this poverty barrier than existing coping mechanisms reliant on subsidies from other water consumers.

  14. 18 CFR 367.9020 - Account 902, Meter reading expenses.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Account 902, Meter... GAS ACT Operation and Maintenance Expense Chart of Accounts § 367.9020 Account 902, Meter reading... customer meters, and determining consumption when performed by employees engaged in reading meters. (b...

  15. Multiphase flow metering: 4 years on

    Energy Technology Data Exchange (ETDEWEB)

    Falcone, G.; Hewitt, G.F.; Alimonti, C.; Harrison, B.

    2005-07-01

    Since the authors' last review in 2001 [1], the use of Multiphase Flow Metering (MFM) within the oil and gas industry continues to grow apace, being more popular in some parts of the world than others. Since the early 1990's, when the first commercial meters started to appear, there have been more than 1,600 field applications of MFM for field allocation, production optimisation and mobile well testing. As the authors predicted, wet gas metering technology has improved to such an extent that its use has rapidly increased worldwide. A ''who's who'' of the MFM sector is provided, which highlights the mergers in the sector and gives an insight into the meters and measurement principles available today. Cost estimates, potential benefits and reliability in the field of the current MFM technologies are revisited and brought up to date. Several measurements technologies have resurfaced, such as passive acoustic energy patterns, infrared wavelengths, Nuclear Magnetic Resonance (NMR) and Electrical Capacitance Tomography (ECT), and they are becoming commercial. The concept of ''virtual metering'', integrated with ''classical MFM'', is now widely accepted. However, sometimes the principles of the MFM measurements themselves are forgotten, submerged in the sales and marketing hype. (author) (tk)

  16. Manage costs and revenues by achieving continuous measurement certainty with the Auto-Adjust Turbo Meter; Gerez les couts et les recettes en acquerant une certitude continuelle de mesure grace au Auto-Adjust Turbo Meter

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, D. [Invensys Energy Metering, Pennsylvania (United States)

    2000-07-01

    Uncertainty in flow measurement and its consequent ramifications are accepted as normal costs of transporting and distributing natural gas. However, a notable advancement in turbine meter technology, pioneered by Invensys Energy Metering, uses two rotors in a tandem configuration to offer unique capabilities beyond those of the tried-and-proven, single-rotor turbine. A flow meter, which monitors its own performance and adjusts its measurement, on a real-time basis, for any deviations from its initial calibration, could largely eliminate many of the costs and lost revenue associated with flow metering and measurement uncertainty. The dual-rotor turbine, trade named the Auto-Adjust Turbo Meter (AAT), is such a flow meter; it provides Continuous Measurement Certainty, with the accompanying potential for enhanced management of costs and revenues. Proprietary algorithms in the AAT's secondary electronics correlate the velocities of the main rotor and the downstream sensing rotor, over the full range of the meter's rated capacity and pressure, such that a real-time adjustment to the indicated volume corrects it to the actual volume. Improved gas accountability results, and substantial savings related to meter site visits, meter testing and repair, preventive maintenance programs, and measurement disputes can be realized. Test data and case histories from a broad range of end users are related to demonstrate areas of potential savings and revenue recovery. (author)

  17. Comparison of five portable peak flow meters

    Directory of Open Access Journals (Sweden)

    Glaucia Nency Takara

    2010-01-01

    Full Text Available OBJECTIVE: To compare the measurements of spirometric peak expiratory flow (PEF from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. METHODS: Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05, Spearman's correlation test and Bland-Altman's agreement test. RESULTS: The median and interquartile ranges for the spirometric values and the Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® meters were 428 (263-688 L/min, 450 (350-800 L/min, 420 (310-720 L/min, 380 (300-735 L/min, 400 (310-685 L/min and 415 (335-610 L/min, respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone® (p<0.001 and Galemed ® (p<0.01 meters. There was no agreement between the spirometric values and the five PEF meters. CONCLUSIONS: The results suggest that the values recorded from Galemed® meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone® meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  18. Experiment of aerosol-release time for a novel automatic metered dose inhaler

    Directory of Open Access Journals (Sweden)

    Mingrong Zhang

    2016-05-01

    Full Text Available The objective of this study was to evaluate the aerosol-release time in the development of a new automatic adapter for metered dose inhaler. With this device, regular manually operated metered dose inhalers become automatic. During the study, an inhalation simulator was designed and tested with the newly developed mechatronic system. By adjusting the volume and the pressure of the vacuum tank, most human inhalation waveforms were able to simulate. As an example, regular quick-deep and slow-deep waveforms were matched within reasonable accuracy. Finally, with the help of dynamic image processing, the aerosol-release time (Tr was carefully measured and fully discussed, including the switch-on time (Ts, the mechatronics-hysteresis (Tm and the intentional-delay (Ti. Under slow-deep inhalation condition which is suitable for metered dose inhaler medicine delivery, the switch-on flow-rate could reach as low as 10 L/min, and the corresponding switch-on time was approximately 0.20 s. While the mechatronics-hysteresis depended on the brand of metered dose inhaler, assuming there was no intentional-delay, the aerosol-release time could be as low as 0.40 and 0.60 s, respectively, for two commercially available metered dose inhalers studied in this article. Therefore, this newly developed mechatronic adapter system could ensure aerosol-release time (Tr within satisfactory range for metered dose inhalers.

  19. Calibration of ionization chamber survey meter

    International Nuclear Information System (INIS)

    Kadhim, A.K.; Kadni, T.B.

    2016-01-01

    Radiation measuring devices need to process calibration which lose their sensitivity and the extent of the response and the amount of stability under a changing conditions from time to time and this period depends on the nature and use of field in which used devices. A comparison study was done toa (45 I P) ( ionization chamber survey meter) and this showed the variation factor in five different years. This study also displayed the concept of radiation instrument calibration and necessity of every year calibration of them.In this project we used the five years calibration data for ionization chamber survey meter model Inspector (1/C F). the value deviation (∆ %) of Cfs for four years of calibration in comparison of C F for the year 2007 are very high and the device under research is not good to use in field and reliable because the ionization chamber is very sensitive to humidity and must calibrate a year or less, or due ing every two years and must maintain carefully to reduce the discarded effects the measurements.

  20. Woody Biomass Conversion to JP-8 Fuels

    Science.gov (United States)

    2014-02-15

    Fermentation of Conditioned Extract or Brownstock to Lipids SUB 5 Mixed Culture Fermentation of Mixed-sugars in Raw extract to Mixed Acids SUB 6 TDO...avoiding the need for producing clean simple sugars tluough controlled hydrolysis, and detoxification in a particular case of fermentation ...according to high temperature simulated distillation (ASTM 7169) shown in Figure 5. Figure 5: Boiling point distribution data for raw TDO

  1. Development of An Advanced JP-8 Fuel

    Science.gov (United States)

    1993-12-01

    included the Microthermal Precipitation Test (MTP), Fuel Reactor Test, Hot Liquid Process Simulator (HLPS), and Isothermal Corrosion Oxidation Test (ICOT... Microthermal Precipitation Test The impetus for this development effort was the need for a screening test that could discriminate between fuels of...varying propensity to produce thermally induced insoluble particulate material in the bulk fuel. The Microthermal Precipitation (MTP) test thermally

  2. JP-8 Reformation for Fuel Cell Applications

    National Research Council Canada - National Science Library

    Lee, Ivan C; Schmidt, Lanny D

    2004-01-01

    ... (hydrogen and carbon monoxide) selectivity with a rhodium-based catalyst. Time-on-stream experiment indicates that the catalysts remains stable and active for at least 4 hours using a jet fuel (310 ppm sulfur...

  3. Intelligent Metering for Urban Water: A Review

    Directory of Open Access Journals (Sweden)

    Rodney Stewart

    2013-07-01

    Full Text Available This paper reviews the drivers, development and global deployment of intelligent water metering in the urban context. Recognising that intelligent metering (or smart metering has the potential to revolutionise customer engagement and management of urban water by utilities, this paper provides a summary of the knowledge-base for researchers and industry practitioners to ensure that the technology fosters sustainable urban water management. To date, roll-outs of intelligent metering have been driven by the desire for increased data regarding time of use and end-use (such as use by shower, toilet, garden, etc. as well as by the ability of the technology to reduce labour costs for meter reading. Technology development in the water sector generally lags that seen in the electricity sector. In the coming decade, the deployment of intelligent water metering will transition from being predominantly “pilot or demonstration scale” with the occasional city-wide roll-out, to broader mainstream implementation. This means that issues which have hitherto received little focus must now be addressed, namely: the role of real-time data in customer engagement and demand management; data ownership, sharing and privacy; technical data management and infrastructure security, utility workforce skills; and costs and benefits of implementation.

  4. Novel Magnetic Field Meter Based on Giant Magneto-impedance (GMI Effect

    Directory of Open Access Journals (Sweden)

    K. Nesteruk

    2006-03-01

    Full Text Available A novel magnetic field GMI-sensor/meter has been invented and designed. Its laboratory model was constructed and tested, demonstrating the sensitivity of 1.10–8 T (100 mGs. The principle of operation of this meter is based on changes of the quality factor of the resonance circuit a part of which is a magnetic GMI sensing element.These changes are due to variations in the real component of the impedance of this element caused by an external DC-field. The sensing element is in the form of a piece of the “non-magnetostrictive” amorphous ribbon. Magnetic field modulation of an acoustic frequency and feedback circuit (compensating field applied to the device, significantly increases stability and linearity of the measuring system.

  5. Bipartite Diametrical Graphs of Diameter 4 and Extreme Orders

    Directory of Open Access Journals (Sweden)

    Salah Al-Addasi

    2008-01-01

    in which this upper bound is attained, this graph can be viewed as a generalization of the Rhombic Dodecahedron. Then we show that for any ≥2, the graph (2,2 is the unique (up to isomorphism bipartite diametrical graph of diameter 4 and partite sets of cardinalities 2 and 2, and hence in particular, for =3, the graph (6,8 which is just the Rhombic Dodecahedron is the unique (up to isomorphism bipartite diametrical graph of such a diameter and cardinalities of partite sets. Thus we complete a characterization of -graphs of diameter 4 and cardinality of the smaller partite set not exceeding 6. We prove that the neighborhoods of vertices of the larger partite set of (2,2 form a matroid whose basis graph is the hypercube . We prove that any -graph of diameter 4 is bipartite self complementary, thus in particular (2,2. Finally, we study some additional properties of (2,2 concerning the order of its automorphism group, girth, domination number, and when being Eulerian.

  6. Research on Operation Assessment Method for Energy Meter

    Science.gov (United States)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng

    2018-03-01

    The existing electric energy meter rotation maintenance strategy regularly checks the electric energy meter and evaluates the state. It only considers the influence of time factors, neglects the influence of other factors, leads to the inaccuracy of the evaluation, and causes the waste of resources. In order to evaluate the running state of the electric energy meter in time, a method of the operation evaluation of the electric energy meter is proposed. The method is based on extracting the existing data acquisition system, marketing business system and metrology production scheduling platform that affect the state of energy meters, and classified into error stability, operational reliability, potential risks and other factors according to the influencing factors, based on the above basic test score, inspecting score, monitoring score, score of family defect detection. Then, according to the evaluation model according to the scoring, we evaluate electric energy meter operating state, and finally put forward the corresponding maintenance strategy of rotation.

  7. Suitable RF spectrum in ISM band for 2-way advanced metering network in India

    Science.gov (United States)

    Mishra, A.; Khan, M. A.; Gaur, M. S.

    2013-01-01

    The ISM (Industrial Scientific and Medical) bands in the radio frequency space in India offer two alternative spectra to implement wireless network for advanced metering infrastructure (AMI). These bands lie in the range of 2.4GHz and sub-GHz frequencies 865 to 867 MHz This paper aims to examine the suitability of both options by designing and executing experiments in laboratory as well as carrying out field trials on electricity meters to validate the selected option. A parameter, communication effectiveness index (CEI2) is defined to measure the effectiveness of 2 way data communication (packet exchange) between two points under different scenarios of buildings and free space. Both 2.4 GHz and Sub-GHz designs were implemented to compare the results. The experiments were conducted across 3 floors of a building. Validation of the selected option was carried out by conducting a field trial by integrating the selected radio frequency (RF) modem into the single phase electricity meters and installing these meters across three floors of the building. The methodology, implementation details, observations and resulting analytical conclusion are described in the paper.

  8. 10 CFR 451.7 - Metering requirements.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Metering requirements. 451.7 Section 451.7 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION RENEWABLE ENERGY PRODUCTION INCENTIVES § 451.7 Metering requirements. The net electric energy generated and sold (kilowatt-hours) by the owner or operator of a qualified...

  9. New, small, fast acting blood glucose meters--an analytical laboratory evaluation.

    Science.gov (United States)

    Weitgasser, Raimund; Hofmann, Manuela; Gappmayer, Brigitta; Garstenauer, Christa

    2007-09-22

    Patients and medical personnel are eager to use blood glucose meters that are easy to handle and fast acting. We questioned whether accuracy and precision of these new, small and light weight devices would meet analytical laboratory standards and tested four meters with the above mentioned conditions. Approximately 300 capillary blood samples were collected and tested using two devices of each brand and two different types of glucose test strips. Blood from the same samples was used for comparison. Results were evaluated using maximum deviation of 5% and 10% from the comparative method, the error grid analysis, the overall deviation of the devices, the linear regression analysis as well as the CVs for measurement in series. Of all 1196 measurements a deviation of less than 5% resp. 10% from the reference method was found for the FreeStyle (FS) meter in 69.5% and 96%, the Glucocard X Meter (GX) in 44% and 75%, the One Touch Ultra (OT) in 29% and 60%, the Wellion True Track (WT) in 28.5% and 58%. The error grid analysis gave 99.7% for FS, 99% for GX, 98% for OT and 97% for WT in zone A. The remainder of the values lay within zone B. Linear regression analysis resembled these results. CVs for measurement in series showed higher deviations for OT and WT compared to FS and GX. The four new, small and fast acting glucose meters fulfil clinically relevant analytical laboratory requirements making them appropriate for use by medical personnel. However, with regard to the tight and restrictive limits of the ADA recommendations, the devices are still in need of improvement. This should be taken into account when the devices are used by primarily inexperienced persons and is relevant for further industrial development of such devices.

  10. A Scalable Smart Meter Data Generator Using Spark

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Liu, Xiufeng; Danalachi, Sergiu

    2017-01-01

    Today, smart meters are being used worldwide. As a matter of fact smart meters produce large volumes of data. Thus, it is important for smart meter data management and analytics systems to process petabytes of data. Benchmarking and testing of these systems require scalable data, however, it can ...

  11. Multichannel Distribution Meter: A Veritable Solution in Power ...

    African Journals Online (AJOL)

    Partitioned apartments in commercial buildings particularly in congested environments shares energy supply meters among several users. This often leads to disputes and results to power theft in the form of unpaid bills and meter tampering. This paper described how power from a single supply meter can be adequately ...

  12. 40 CFR 1065.245 - Sample flow meter for batch sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Sample flow meter for batch sampling... Sample flow meter for batch sampling. (a) Application. Use a sample flow meter to determine sample flow... difference between a diluted exhaust sample flow meter and a dilution air meter to calculate raw exhaust flow...

  13. Improvement of Estimation method for two-phase flow in a large-diameter pipe. Pt. 4. Effect of the inlet boundary condition of the upward flow section on flow characteristics

    International Nuclear Information System (INIS)

    Yoneda, Kimitoshi; Okawa, Tomio; Zhou, Shirong

    1999-01-01

    In nuclear power plants, many large-diameter pipes are subject to gas-liquid two-phase flow. For rational design and performance estimation, the flow in the pipes should be predicted accurately. With the correlation used at present, however, the flow analysis can not reach desirable precision. This is partly due to the lack of understanding of the two-phase flow characteristics in large-diameter pipes. Therefore, steam-water two-phase flow in a vertical pipe (155 mm i.d.) was investigated empirically. Lateral distribution data of phase volume fraction, gas velocity and bubble diameter were obtained. The effects of the inlet boundary condition were also observed. The drift velocity in the developing region was considerably affected by the inlet boundary condition. By deriving the correlation of mean bubble diameter as a function of void fraction and pressure, the empirical data was predicted with high accuracy compared with the existing correlation used in best-estimate codes of nuclear reactor safety analysis. (author)

  14. The relationships between common measures of glucose meter performance.

    Science.gov (United States)

    Wilmoth, Daniel R

    2012-09-01

    Glucose meter performance is commonly measured in several different ways, including the relative bias and coefficient of variation (CV), the total error, the mean absolute relative deviation (MARD), and the size of the interval around the reference value that would be necessary to contain a meter measurement at a specified probability. This fourth measure is commonly expressed as a proportion of the reference value and will be referred to as the necessary relative deviation. A deeper understanding of the relationships between these measures may aid health care providers, patients, and regulators in comparing meter performances when different measures are used. The relationships between common measures of glucose meter performance were derived mathematically. Equations are presented for calculating the total error, MARD, and necessary relative deviation using the reference value, relative bias, and CV when glucose meter measurements are normally distributed. When measurements are also unbiased, the CV, total error, MARD, and necessary relative deviation are linearly related and are therefore equivalent measures of meter performance. The relative bias and CV provide more information about meter performance than the other measures considered but may be difficult for some audiences to interpret. Reporting meter performance in multiple ways may facilitate the informed selection of blood glucose meters. © 2012 Diabetes Technology Society.

  15. Wanted: competitive metering infrastructure. Metering must be automated in a high grade; Gesucht: wettbewerbsfaehige Metering-Infrastruktur. Metering muss hochgradig automatisiert werden

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Elschner, C. [T-Systems Enterprise Services GmbH, Bonn (Germany). Business Development und Marketing

    2008-04-21

    Accurate on-time consumption metering and data transmission are increasingly important as energy markets are being deregulated. Measuring and information systems combine measurements with intelligent modules for automatic transmission of consumption information. A meaningful cost-benefit comparision results only when the total system is considered. Telecommunication companies as ICT service systems and service sectors can do a clear contribution to the total system. (orig./GL)

  16. Smart meter implementation plan : report of the Board to the Minister

    International Nuclear Information System (INIS)

    2005-01-01

    This report provides detailed information about Ontario's smart meter implementation plan. The smart metering system will measure how much electricity a customer uses on an hourly basis, with data being transferred daily to local electricity distributors. Energy prices will vary according to the time of day when energy was being consumed, a system that supports current methods of charging larger customers. The plan proposes that all new and existing customers in Ontario have some type of smart meter by 2010 as part of a two-phased plan. Customers will receive timely information on consumption, and distributors will offer variable pricing plans. It was advised that costs be included in the distribution rate immediately upon installation of smart meters. Detailed information on implementation, smart metering costs, minimum requirements, and non-commodity time of use rates were presented. Critical tasks for establishing a framework for implementation included: ministerial approval of the plan; identification of a program coordinator; the establishment of a correct regulatory framework; a vendor approval process requiring appropriate permissions for radio frequency licences; technology pilots on behalf of distributors to assure adequate adaptation and the development of procedures concerning procurement, internal schedules and deployment; coordination between government, regulatory bodies and distributors towards the establishment of communication strategies, implementation plans and distributor approaches. 5 tabs., 6 figs

  17. Analysis of a quantum nondemolition speed-meter interferometer

    International Nuclear Information System (INIS)

    Purdue, Patricia

    2002-01-01

    In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g. LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors rather than monitoring their relative position. This paper describes and analyzes the most straightforward design for a speed meter interferometer that accomplishes this--a design (due to Braginsky, Gorodetsky, Khalili and Thorne) that is analogous to a microwave-cavity speed meter conceived by Braginsky and Khalili. A mathematical mapping between the microwave speed meter and the optical interferometric speed meter is developed and is used to show [in accord with the speed being a quantum nondemolition observable] that in principle the interferometric speed meter can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies, and can do so without the use of squeezed vacuum or any auxiliary filter cavities at the interferometer's input or output. However, in practice, to reach or beat the SQL, this specific speed meter requires exorbitantly high input light power. The physical reason for this is explored, along with other issues such as constraints on performance due to optical dissipation. This analysis forms a foundation for ongoing attempts to develop a more practical variant of an interferometric speed meter and to combine the speed meter concept with other ideas to yield a promising LIGO-III/EURO interferometer design that entails low laser power

  18. Metering in the gas supply sector; Metering in der Gasversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Wernekinck, U. [RWE Westfalen-Weser-Ems, Recklinghausen (Germany)

    2007-10-15

    The new conditions of competition in the gas supply sector have strongly increased the requirements on gas grid operators. Mainly an exact gas metering and -accouting will become more and more important. The systems and procedures are presented in detail in this contribution. (GL)

  19. Mixing of the lowest-lying qqq configurations with JP =1/2- in different hyperfine interaction models

    Science.gov (United States)

    Chen, Jia; An, Chunsheng; Chen, Hong

    2018-02-01

    We investigate mixing of the lowest-lying qqq configurations with JP = 1/2- caused by the hyperfine interactions between quarks mediated by Goldstone Boson Exchange, One Gluon Exchange, and both Goldstone Boson and One Gluon exchange, respectively. The first orbitally excited nucleon, Σ, Λ and Ξ states are considered. Contributions of both the contact term and tensor term are taken into account. Our numerical results show that mixing of the studied configurations in the two employed hyperfine interaction models are very different. Therefore, the present results, which should affect the strong and electromagnetic decays of baryon resonances, may be used to examine the present employed hyperfine interaction models. Supported by National Natural Science Foundation of China (11675131,11645002), Chongqing Natural Science Foundation (cstc2015jcyjA00032) and Fundamental Research Funds for the Central Universities (SWU115020)

  20. Sugar maple height-diameter and age-diameter relationships in an uneven-aged northern hardwood stand

    Science.gov (United States)

    Laura S. Kenefic; R.D. Nyland

    1999-01-01

    Sugar maple (Acer saccharum Marsh.) height-diameter and age-diameter relationships are explored in a balanced uneven-aged northern hardwood stand in central New York. Results show that although both height and age vary considerably with diameter, these relationships can be described by statistically valid equations. The age-diameter relationship...

  1. RAE: The Rainforest Automation Energy Dataset for Smart Grid Meter Data Analysis

    Directory of Open Access Journals (Sweden)

    Stephen Makonin

    2018-02-01

    Full Text Available Datasets are important for researchers to build models and test how well their machine learning algorithms perform. This paper presents the Rainforest Automation Energy (RAE dataset to help smart grid researchers test their algorithms that make use of smart meter data. This initial release of RAE contains 1 Hz data (mains and sub-meters from two residential houses. In addition to power data, environmental and sensor data from the house’s thermostat is included. Sub-meter data from one of the houses includes heat pump and rental suite captures, which is of interest to power utilities. We also show an energy breakdown of each house and show (by example how RAE can be used to test non-intrusive load monitoring (NILM algorithms.

  2. Sex-related differences in the anteroposterior diameter of the foetal cisterna magna

    Energy Technology Data Exchange (ETDEWEB)

    Tao, G. [Department of Ultrasound, Qilu hospital of Shandong University, Jinan (China); Yew, D.T. [Department of Anatomy, Chinese University of Hong Kong (Hong Kong); Gu, T.; Liu, S.; Ma, Z.; Zhan, X.; Cheng, L. [Department of Ultrasound, Qilu hospital of Shandong University, Jinan (China); Li, C. [Department of Ultrasound, Qilu hospital of Shandong University, Jinan (China)], E-mail: chuanfuli2006@hotmail.com

    2008-09-15

    Aim: To measure the anteroposterior diameter of the foetal cisterna magna and observe whether there are differences according to sex. Materials and methods: Three hundred and thirty-seven Chinese women with low-risk pregnancies and a singleton foetus between 22 and 38 weeks' gestational age were included in this retrospective study. Informed consent of the volunteer subjects and hospital authority approval were first obtained. Double-blinded for gender, the anteroposterior diameter of the cisterna magna of the foetuses was measured by transabdominal sonography. Magnetic resonance imaging (MRI) was used for those foetuses with mega cisterna magna. All of the foetuses were healthy by prenatal and postnatal examination, including physical and imaging examination. Results: The mean anteroposterior diameter of the cisterna magna of all foetuses was 8.01 {+-} 1.79 mm. The anteroposterior diameter of the cisterna magna had no obvious correlation with the gestational age. The mean anteroposterior diameter of the cisterna magna of 179 male foetuses was 8.63 {+-} 2.16 mm, and the mean anteroposterior diameter of the cisterna magna of 158 female foetuses was 7.87 {+-} 1.74 mm. The size difference was statistically significant (p < 0.001). In the 33 foetuses with mega cisterna magna, the number of male foetuses was greater than female foetuses, and the proportion of the foetuses with mega cisterna magna in the male group was significantly higher than the foetuses in the female group (p < 0.05). Conclusion: Male foetuses had slightly larger anteroposterior diameters of the cisterna magna than female foetuses. The study would be useful for creating normal range values for the cisterna magna of male and female foetuses.

  3. A flow meter for ultrasonically measuring the flow velocity of fluids

    DEFF Research Database (Denmark)

    2015-01-01

    The invention regards a flow meter for ultrasonically measuring the flow velocity of fluids comprising a duct having a flow channel with an internal cross section comprising variation configured to generate at least one acoustic resonance within the flow channel for a specific ultrasonic frequency......, and at least two transducers for generating and sensing ultrasonic pulses, configured to transmit ultrasonic pulses at least at said specific ultrasonic frequency into the flow channel such that the ultrasonic pulses propagate through a fluid flowing in the flow channel, wherein the flow meter is configured...

  4. Smart Metering. Synergies within medium voltage automation; Synergien durch Smart Metering. Automatisierung auf Mittelspannungsebene

    Energy Technology Data Exchange (ETDEWEB)

    Maas, Peter [IDS GmbH, Ettlingen (Germany)

    2010-11-15

    Transparent interdivisional system solutions are an indispensable and decisive precondition for the optimization of business processes. The implementation of a Smart Metering solution does not only provide data for billing purposes, but also renders important data for network operation. Synergies can be achieved through the use of a common infrastructure which covers both the needs of Smart Metering and network operation. An open architecture of the solution allows for the future integration of further services of the domains Smart Grid and Smart Home. (orig.)

  5. Smart meters and routers radiofrequency disturbances study with pacemakers and implantable cardiac defibrillators.

    Science.gov (United States)

    Ostiguy, Geneviève; Black, Tom; Bluteau, Louis-Jean; Dupont, Louis; Dyrda, Katia; Girard, Guillaume; Nguyen, Duc-Hai; Plante, Michel; Thibault, Bernard

    2013-11-01

    There is no scientific literature that examines radiofrequency (RF) interference from Smart Meters with cardiac implantable electronic devices (CIEDs). The objective of this in vitro study was to assess any potential interference with Medtronic CIEDs (Medtronic Inc., Minneapolis, MN, USA). In the Quebec testing, five models of Medtronic CIEDs were placed in an acrylic cylinder filled with a saline solution and faced a Landis+Gyr Smart Meter or Router (Landis+Gyr AG, Zug, Switzerland). The distance between CIEDs and the meter casing or router antenna was 10 cm. The Meter's normal operating conditions were modified to artificially set the number of impulsions at an abnormally high level (one, two, and three impulses per second). Each scenario was repeated one to five times, for 1 minute each. In the U.S. testing, 6 cm and 15 cm (∼2.25' and ∼6') separated the six models of Medtronic CIEDs from the Schlumberger Smart Meter (Itron Inc., Liberty Lake, WA, USA), which generally sent out a 96-bit Standard Consumption Message over 3 seconds. The transmission varied in frequencies along with the interval between cycles. A total of 6,966 RF transmissions were completed during the 34 tests conducted in Quebec. In the United States, the CIED was exposed to the meter for 10 minutes to provide a minimum of 200 completed RF transmissions. No interference was observed in worst-case scenarios (testing of meters and CIEDs at their performance limits). Landis+Gyr Smart Meters/Routers and Schlumberger Smart Meters do not interfere with the functioning of the Medtronic CIEDs tested, when placed, respectively, 10 cm and 6 cm and 15 cm apart. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  6. Production of Monodisperse Cerium Oxide Microspheres with Diameters near 100 µm by Internal Gelation Sol-Gel Methods

    Energy Technology Data Exchange (ETDEWEB)

    Katalenich, Jeffrey A.; Kitchen, Brian B.; Pierson, Bruce

    2018-05-01

    Internal gelation sol-gel methods have used a variety of sphere forming methods in the past to produce metal oxide microspheres, but typically with poor control over the size uniformity at diameters near 100 µm. This work describes efforts to make and measure internal gelation, sol-gel microspheres with very uniform diameters in the 100 – 200 µm size range using a two-fluid nozzle. A custom apparatus was used to form aqueous droplets of sol-gel feed solutions in silicone oil and heat them to cause gelation of the spheres. Gelled spheres were washed, dried, and sintered prior to mounting on glass slides for optical imaging and analysis. Microsphere diameters and shape factors were determined as a function of silicone oil flow rate in a two-fluid nozzle and the size of a needle dispensing the aqueous sol-gel solution. Nine batches of microspheres were analyzed and had diameters ranging from 65.5 ± 2.4 µm for the smallest needle and fastest silicone oil flow rate to 211 ± 4.7 µm for the largest needle and slowest silicone oil flow rate. Standard deviations for measured diameters were less than 8% for all samples and most were less than 4%. Microspheres had excellent circularity with measured shape factors of 0.9 – 1. However, processing of optical images was complicated by shadow effects in the photoresist layer on glass slides and by overlapping microspheres. Based on calculated flow parameters, microspheres were produced in a simple dripping mode in the two-fluid nozzle. Using flow rates consistent with a simple dripping mode in a two-fluid nozzle configuration allows for very uniform oxide microspheres to be produced using the internal-gelation sol-gel method.

  7. Calibration of dose meters used in radiotherapy

    International Nuclear Information System (INIS)

    1979-01-01

    This manual is a practical guide, not a comprehensive textbook, to the instrumentation and procedures necessary to calibrate a radiation dose meter used in clinical practice against a secondary standard dose meter

  8. Comparison of five portable peak flow meters.

    Science.gov (United States)

    Takara, Glaucia Nency; Ruas, Gualberto; Pessoa, Bruna Varanda; Jamami, Luciana Kawakami; Di Lorenzo, Valéria Amorim Pires; Jamami, Mauricio

    2010-05-01

    To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone, Assess, Galemed, Personal Best and Vitalograph peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (pmeters were 428 (263-688 L/min), 450 (350-800 L/min), 420 (310-720 L/min), 380 (300-735 L/min), 400 (310-685 L/min) and 415 (335-610 L/min), respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone(R) (pmeters. There was no agreement between the spirometric values and the five PEF meters. The results suggest that the values recorded from Galemed meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  9. In-situ calibration of clinical built-in KAP meters with traceability to a primary standard using a reference KAP meter.

    Science.gov (United States)

    Malusek, A; Helmrot, E; Sandborg, M; Grindborg, J-E; Carlsson, G Alm

    2014-12-07

    The air kerma-area product (KAP) is used for settings of diagnostic reference levels. The International Atomic Energy Agency (IAEA) recommends that doses in diagnostic radiology (including the KAP values) be estimated with an accuracy of at least ± 7% (k = 2). Industry standards defined by the International Electrotechnical Commission (IEC) specify that the uncertainty of KAP meter measurements should be less than ± 25% (k = 2). Medical physicists willing to comply with the IAEA's recommendation need to apply correction factors to KAP values reported by x-ray units. The aim of this work is to present and evaluate a calibration method for built-in KAP meters on clinical x-ray units. The method is based on (i) a tandem calibration method, which uses a reference KAP meter calibrated to measure the incident radiation, (ii) measurements using an energy-independent ionization chamber to correct for the energy dependence of the reference KAP meter, and (iii) Monte Carlo simulations of the beam quality correction factors that correct for differences between beam qualities at a standard laboratory and the clinic. The method was applied to the KAP meter in a Siemens Aristos FX plus unit. It was found that values reported by the built-in KAP meter differed from the more accurate values measured by the reference KAP meter by more than 25% for high tube voltages (more than 140 kV) and heavily filtered beams (0.3 mm Cu). Associated uncertainties were too high to claim that the IEC's limit of 25% was exceeded. Nevertheless the differences were high enough to justify the need for a more accurate calibration of built-in KAP meters.

  10. Analysing Smart Metering Systems from a Consumer Perspective

    Science.gov (United States)

    Yesudas, Rani

    Many countries are deploying smart meters and Advanced Metering Infrastructure systems as part of demand management and grid modernisation efforts. Several of these projects are facing consumer resistance. The advertised benefits to the consumer appear mainly monetary but detailed analysis shows that financial benefits are hard to realise since the fixed services charges are high. Additionally, the data collected from smart meters have security and privacy implications for the consumer. These projects failed to consider end-users as an important stakeholder group during planning stages resulting in the design and roll-out of expensive systems, which do not demonstrate clear consumer benefits. The overall goal of the research reported in this thesis was to improve the smart metering system to deliver consumer benefits that increase confidence and acceptance of these projects. The smart metering system was examined from an end-user perspective for realistic insights into consumer concerns. Processes from Design Science Research methodology were utilised to conduct this research due to the utilitarian nature of the objective. Consumer segmentation was central to the proposed measures. Initially, a consumer-friendly risk analysis framework was devised, and appropriate requirement elicitation techniques were identified. Control options for smart meter data transfer and storage were explored. Various scenarios were analysed to determine consumer-friendly features in the smart metering system, including control options for smart meter data transfer and storage. Proposed functionalities (billing choices, feedback information and specific configurations to match the needs of different user segments) were studied using the Australian smart metering system. Smart meters vary in capabilities depending on the manufacturer, mode and place of deployment. The research showed that features proposed in this thesis are implementable in smart meters, by examining their applicability

  11. Liquid ultrasonic flow meters for crude oil measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kalivoda, Raymond J.; Lunde, Per

    2005-07-01

    Liquid ultrasonic flow meters (LUFMs) are gaining popularity for the accurate measurement of petroleum products. In North America the first edition of the API standard ''Measurement of liquid hydrocarbons by ultrasonic flow meters using transit time technology'' was issued in February 2005. It addresses both refined petroleum products and crude oil applications. Its field of application is mainly custody transfer applications but it does provide general guidelines for the installation and operation of LUFM's other applications such as allocation, check meters and leak detection. As with all new technologies performance claims are at times exaggerated or misunderstood and application knowledge is limited. Since ultrasonic meters have no moving parts they appear to have fewer limitations than other liquid flow meters. Liquids ultrasonic flow meters, like turbine meters, are sensitive to fluid properties. It is increasingly more difficult to apply on high viscosity products then on lighter hydrocarbon products. Therefore application data or experience on the measurement of refined or light crude oil may not necessarily be transferred to measuring medium to heavy crude oils. Before better and more quantitative knowledge is available on how LUFMs react on different fluids, the arguments advocating reduced need for in-situ proving and increased dependency on laboratory flow calibration (e.g. using water instead of hydrocarbons) may be questionable. The present paper explores the accurate measurement of crude oil with liquid ultrasonic meters. It defines the unique characteristics of the different API grades of crude oils and how they can affect the accuracy of the liquid ultrasonic measurement. Flow testing results using a new LUFM design are discussed. The paper is intended to provide increased insight into the potentials and limitations of crude oil measurement using ultrasonic flow meters. (author) (tk)

  12. Extracting urban water usage habits from smart meter data: a functional clustering approach

    OpenAIRE

    CHEIFETZ, Nicolas; SAME, Allou; NOUMIR, Zineb; SANDRAZ, Anne Claire; FELIERS, Cédric; HEIM, Véronique

    2017-01-01

    Through automated meter reading systems, recent development of smart grids offers the opportunity for an efficient and responsible management of water resources. The present paper describes a novel methodology for identifying relevant usage profiles from hourly water consumption series collected by smart meters located on a water distribution network. The proposed approach operates in two stages. First, an additive time series decomposition model is used in order to extract seasonal patterns ...

  13. Two-stage combustion for reducing pollutant emissions from gas turbine combustors

    Science.gov (United States)

    Clayton, R. M.; Lewis, D. H.

    1981-01-01

    Combustion and emission results are presented for a premix combustor fueled with admixtures of JP5 with neat H2 and of JP5 with simulated partial-oxidation product gas. The combustor was operated with inlet-air state conditions typical of cruise power for high performance aviation engines. Ultralow NOx, CO and HC emissions and extended lean burning limits were achieved simultaneously. Laboratory scale studies of the non-catalyzed rich-burning characteristics of several paraffin-series hydrocarbon fuels and of JP5 showed sooting limits at equivalence ratios of about 2.0 and that in order to achieve very rich sootless burning it is necessary to premix the reactants thoroughly and to use high levels of air preheat. The application of two-stage combustion for the reduction of fuel NOx was reviewed. An experimental combustor designed and constructed for two-stage combustion experiments is described.

  14. Completion Report for the Well ER-6-2 Site Corrective Action Unit 97: Yucca Flat - Climax Mine

    International Nuclear Information System (INIS)

    2008-01-01

    Well ER-6-2 and its satellite hole, Well ER-6-2 No.1, were drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of the Nevada Environmental Restoration Project at the Nevada Test Site, Nye County, Nevada. Well ER-6-2 was drilled in two stages in 1993 and 1994; the satellite hole, Well ER-6-2 No.1 was drilled nearby in 1993 but was abandoned. The wells were drilled as part of a hydrogeologic investigation program for the Yucca Flat-Climax Mine Corrective Action Unit Number 97, in the northeastern portion of the Nevada Test Site. The wells are located in Yucca Flat, within Area 6 of the Nevada Test Site. The wells provided information regarding the radiological and hydrogeological environment in a potentially down-gradient position from tests conducted in northern and central Yucca Flat. Construction of Well ER-6-2 began with a 1.2-meter-diameter surface conductor hole, which was drilled and cased off to a depth of 30.8 meters below the surface. A 50.8-centimeter diameter surface hole was then rotary drilled to the depth of 578.5 meters and cased off to the depth of 530.4 meters. The hole diameter was then reduced to 27.0 centimeters, and the borehole was advanced to a temporary depth of 611.4 meters. The borehole was conventionally cored to a total depth of 1,045 meters with a diameter of 14.0 centimeters. Borehole sloughing required cementing and re-drilling of several zones. The open-hole completion accesses the lower carbonate aquifer, the CP thrust fault, and the upper clastic confining unit. A fluid level depth of 543.2 meters was most recently measured in the open borehole in September 2007. No radionuclides were encountered during drilling. The satellite hole Well ER-6-2 No.1 was drilled approximately 15.2 meters north of Well ER-6-2 on the same drill pad. This was planned to be used as an observation well during future hydrologic testing at Well ER-6-2; however, the satellite hole was abandoned at

  15. Ipratropium bromide delivered by metered-dose aerosol to infant ...

    African Journals Online (AJOL)

    Two methods of administration of ipratropium bromide (Atrovent; Boehringer Ingelheim) to wheezing children'< 25 months of age were compared: (i) the conventional nebulisation (15 children); and (ii) a metered-dose aerosol plus spacer and mask (MDA group, 17 children). The drug induced a significant and similar fall in ...

  16. Performance of a new meter designed for assisted monitoring of blood glucose and point-of-care testing.

    Science.gov (United States)

    Macrury, Sandra; Srinivasan, Aparna; Mahoney, John J

    2013-03-01

    Blood glucose (BG) meters used for assisted monitoring of blood glucose (AMBG) require different attributes compared with meters designed for home use. These include safety considerations (i.e., minimized risk of blood-borne pathogen transmission), capability for testing multiple blood sample types, and enhanced performance specifications. The OneTouch® Verio™Pro+ BG meter is designed to incorporate all of these attributes. Meter accuracy was assessed in clinical studies with arterial, venous, and capillary blood samples with a hematocrit range of 22.9-59.8%. The effect of interferents, including anticoagulants, on accuracy was evaluated. The meter disinfection protocol was validated, and instructions for use and user acceptance of the system were assessed. A total of 97% (549/566) of BG measures from all blood sample types and 95.5% (191/200) of arterial blood samples were within ±12 mg/dl or 12.5% of reference measurements. The system was unaffected by 4 anticoagulants and 57 of 59 endogenous and exogenous compounds; it was affected by 2 compounds: pralidoxime iodide and xylose. Bleach wipes were sufficient to disinfect the meter. Users felt that the meter's quality control (QC) prompts would help them to comply with regulatory requirements. The meter provided accurate measurements of different blood samples over a wide hematocrit range and was not affected by 57 physiologic and therapeutic compounds. The QC prompts and specific infection-mitigating design further aid to make this meter system practical for AMBG in care facilities. © 2013 Diabetes Technology Society.

  17. Synergisms between smart metering and smart grid; Synergien zwischen Smart Metering und Smart Grid

    Energy Technology Data Exchange (ETDEWEB)

    Maas, Peter [IDS GmbH, Ettlingen (Germany)

    2010-04-15

    With the implementation of a smart metering solution, it is not only possible to acquire consumption data for billing but also to acquire relevant data of the distribution grid for grid operation. There is still a wide gap between the actual condition and the target condition. Synergies result from the use of a common infrastructure which takes account both of the requirements of smart metering and of grid operation. An open architecture also enables the future integration of further applications of the fields of smart grid and smart home. (orig.)

  18. Advanced Metering Installations – A Perspective from Federal Sites

    Energy Technology Data Exchange (ETDEWEB)

    Earni, Shankar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area

    2016-05-02

    This report is intended to provide guidance to the United States Department of Energy (DOE) and other federal agencies to highlight some of the existing practices related to advanced building metering systems. This study identified some of the existing actions related to advanced meter data and proposes how advanced metered data can be employed to develop robust cost effective measurement and verification (M&V) strategies. This report proposes an integrated framework on how advanced meter data can be used to identify energy conservation opportunities and to develop proactive M&V strategies to ensure that the savings for energy projects are being realized. This information will help improve metering, feedback, and dashboard implementations for reducing energy use at DOE facilities, based on lessons learned from various advanced metering implementations.

  19. FLOW METERS WITH VERY GOOD PERFORMANCES

    Directory of Open Access Journals (Sweden)

    Mircea Dimitrie CAZACU

    2011-11-01

    Full Text Available We present the theoretical calculus of a patented flow meter, concerning such the thermodynamic and aerodynamic calculus, as well as the offered precision to measure the flow of the air in any meteorological conditions. In the same time we remark that the proposed flow meter, by its positioning, has not loss of head.

  20. Wind tunnel tests of modified cross, hemisflo, and disk-gap-band parachutes with emphasis in the transonic range

    Science.gov (United States)

    Foughner, J. T., Jr.; Alexander, W. C.

    1974-01-01

    Transonic wind-tunnel studies were conducted with modified cross, hemisflo, and disk-gap-band parachute models in the wake of a cone-cylinder shape forebody. The basic cross design was modified with the addition of a circumferential constraining band at the lower edge of the canopy panels. The tests covered a Mach number range of 0.3 to 1.2 and a dynamic pressure range from 479 Newtons per square meter to 5746 Newtons per square meter. The parachute models were flexible textile-type structures and were tethered to a rigid forebody with a single flexible riser. Different size models of the modified cross and disk-gap-band canopies were tested to evaluate scale effects. Model reference diameters were 0.30, 0.61, and 1.07 meters (1.0, 2.0, and 3.5 ft) for the modified cross; and nominal diameters of 0.25 and 0.52 meter (0.83 and 1.7 ft) for the disk-gap-band; and 0.55 meter (1.8 ft) for the hemisflo. Reefing information is presented for the 0.61-meter-diameter cross and the 0.52-meter-diameter disk-gap-band. Results are presented in the form of the variation of steady-state average drag coefficient with Mach number. General stability characteristics of each parachute are discussed. Included are comments on canopy coning, spinning, and fluttering motions.

  1. A simple protocol for the routine calibration of pH meters

    Directory of Open Access Journals (Sweden)

    A. FEDERMAN NETO

    2009-01-01

    Full Text Available

    A simplified laboratory protocol for the calibration of pH meters is described and tested. It is based on the use of two analytical primary buffer solutions, potassium hydrogen phthalate and Borax (sodium tetraborate decahydrate of precisely known concentrations and pH. The solutions may be stored at room temperature for long periods, without decomposition and used directly. The calibration of the meter can be checked with standard solutions of sodium dihydrogen phosphate, sodium carbonate, sodium benzoate, sodium salicylate or potassium oxalate. Methods for the purification of Borax and potassium chloride are also given, and a new method for the neutralization of 0.9% saline is suggested. Keywords: pH meters (calibration; saline (0.9%; pH standards; potassium biphthalate; Borax.

  2. Measurements of the diameter of the supernova SN 1987A

    International Nuclear Information System (INIS)

    Karovska, M.; Nisenson, P.; Standley, C.; Heathcote, S.R.

    1991-01-01

    Speckle interferometric measurements of the angular diameter of SN 1987A in the Large Magellanic Cloud, obtained at 664 days after the outburst are presented. Diameters were estimated with milliarcsec precision at 657 nm and 550 nm by fitting model visibility functions to the data corresponding to different intensity distributions for the supernova disk. Measurements made assuming a uniform intensity distribution were compared to the uniform disk measurements obtained from 30 days after the explosion. Diameter measurements obtained near the center of the H-alpha line are consistent with homologous expansion of the supernova shell with a mean velocity of 2850 km/s. The linear least-squares fit to the measurements obtained at other wavelengths from 260 days after the explosion yielded a somewhat lower mean expansion velocity. 8 refs

  3. Ipratropium bromide delivered by metered-dose aerosol to infant ...

    African Journals Online (AJOL)

    1990-08-21

    Aug 21, 1990 ... Two methods of administration of ipratropium bromide. (Atrovent; Boehringer Ingelheim) to wheezing children'< 25 months of age were compared: (I) the conventional nebulisa- tion (15 children); and (iI) a metered-dose aerosol plus spacer and mask (MDA group, 17 children). The drug induced a significant ...

  4. A Prediction-based Smart Meter Data Generator

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Liu, Xiufeng; Nordbjerg, Finn Ebertsen

    2016-01-01

    With the prevalence of cloud computing and In-ternet of Things (IoT), smart meters have become one of the main components of smart city strategy. Smart meters generate large amounts of fine-grained data that is used to provide useful information to consumers and utility companies for decision......, mainly due to privacy issues. This paper proposes a smart meter data generator that can generate realistic energy consumption data by making use of a small real-world dataset as seed. The generator generates data using a prediction-based method that depends on historical energy consumption patterns along......-making. Now-a-days, smart meter analytics systems consist of analytical algorithms that process massive amounts of data. These analytics algorithms require ample amounts of realistic data for testing and verification purposes. However, it is usually difficult to obtain adequate amounts of realistic data...

  5. Bandwidth Analysis of Smart Meter Network Infrastructure

    DEFF Research Database (Denmark)

    Balachandran, Kardi; Olsen, Rasmus Løvenstein; Pedersen, Jens Myrup

    2014-01-01

    Advanced Metering Infrastructure (AMI) is a net-work infrastructure in Smart Grid, which links the electricity customers to the utility company. This network enables smart services by making it possible for the utility company to get an overview of their customers power consumption and also control...... devices in their costumers household e.g. heat pumps. With these smart services, utility companies can do load balancing on the grid by shifting load using resources the customers have. The problem investigated in this paper is what bandwidth require-ments can be expected when implementing such network...... to utilize smart meters and which existing broadband network technologies can facilitate this smart meter service. Initially, scenarios for smart meter infrastructure are identified. The paper defines abstraction models which cover the AMI scenarios. When the scenario has been identified a general overview...

  6. Demineralized water flow cancelling experiments with ice plug into high diameter horizontal tube (300 nominal diameter)

    International Nuclear Information System (INIS)

    Gyongyosi, T.; Valeca, S.; Corbescu, B.; Puiu, D.; Panaitescu, V. N.

    2015-01-01

    The isolation with ice plug of a high diameter horizontal pipeline section is a specific technique for repairs activities/ replacements of components owning to thermo-hydraulic installations working with liquid agents. The application of such technique don.t assumes stopping of the entire system. The ice plugging inside of the pipeline assumes using of a special device and of an own specific technology for application. The paper contains a brief description of the experimental technological facilities used, followed by setting off the main moments in evolution of two experimental tests carried out on the test section with 300 mm nominal diameter for demineralized water and, finally, by a brief results analysis and some conclusions. The paper is dedicated to the specialists working in the research and technological engineering. (authors)

  7. Development of quick-response area-averaged void fraction meter. Application to BWR condition

    Energy Technology Data Exchange (ETDEWEB)

    Iguchi, Tadashi; Watanabe, Hironori; Kimura, Mamoru; Anoda, Yoshinari [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-05-01

    Authors have been developed a practical conductance-type void fraction meter to measure instantaneously area-averaged void fraction in rod bundle. The principle of the meter is based on the fact that the electrical conductance changes with the change of void fraction in gas-liquid two-phase flow. According to air/water two-phase flow experiment, the void fraction was approximated by {alpha}=1-I/I{sub 0}, where {alpha} and I are void fraction and current (I{sub 0} is current at {alpha}=0). Authors investigated the performance of the void fraction meter under high temperature/high pressure conditions (BWR condition; 290degC, 7MPa). The results indicated that the void fraction was approximated by {alpha}=1-I/I{sub 0} even under high temperature/high pressure condition of stem/water flow. However, it is necessary to take account of temperature dependency of water specific conductance. Therefore, authors derived a correction equation for temperature dependency. Further, for applying the void fraction meter to a large-scale facility, it was found to be necessary to reduce the capacitance of the circuit. Then, authors developed the method to reduce the capacitance effect. Finally, authors succeeded to measure the void fraction in 2 x 2 bundle flow path at the range of 0% - 70% in the error of 10% under high temperature/high pressure and mass flux of less than 133 kg/m{sup 2}s. Developed void fraction meter is theoretically not affected by flow rate. Therefore, it can be applied to the condition of oscillating flow. (author)

  8. HJD-I record and analysis meter for nuclear information

    International Nuclear Information System (INIS)

    Di Shaoliang; Huang Yong; Xiao Yanbin

    1992-01-01

    A low-cost, small-volume, multi-function and new model intelligent nuclear electronic meter HJD-I Record and Analysis Meter are stated for Nuclear Information. It's hardware and software were detailed and the 137 Cs spectrum with this meter was presented

  9. Adjustment equipment for reactor radioactivity meter

    International Nuclear Information System (INIS)

    Denisov, V.P.; Malishev, A.N.; Shebanova, L.E.; Kirilyuk, N.A.; Maksimov, Yu.N.; Bessalov, G.G.; Vikhorev, Yu.V.; Lukyanov, M.A.

    1978-01-01

    An activity meter is described movably located in a channel placed in the peripheral biological shielding of a nuclear reactor. It is connected to a weight moving in a second channel by means of a pulley. This arrangement allows locating the radioactivity meter drive on the outer side of the biological shield and vacating space above the reactor body. (Ha)

  10. The reactivity meter and core reactivity

    International Nuclear Information System (INIS)

    Siltanen, P.

    1999-01-01

    This paper discussed in depth the point kinetic equations and the characteristics of the point kinetic reactivity meter, particularly for large negative reactivities. From a given input signal representing the neutron flux seen by a detector, the meter computes a value of reactivity in dollars (ρ/β), based on inverse point kinetics. The prompt jump point of view is emphasised. (Author)

  11. Household Classification Using Smart Meter Data

    Directory of Open Access Journals (Sweden)

    Carroll Paula

    2018-03-01

    Full Text Available This article describes a project conducted in conjunction with the Central Statistics Office of Ireland in response to a planned national rollout of smart electricity metering in Ireland. We investigate how this new data source might be used for the purpose of official statistics production. This study specifically looks at the question of determining household composition from electricity smart meter data using both Neural Networks (a supervised machine learning approach and Elastic Net Logistic regression. An overview of both classification techniques is given. Results for both approaches are presented with analysis. We find that the smart meter data alone is limited in its capability to distinguish between household categories but that it does provide some useful insights.

  12. Water velocity meter

    Science.gov (United States)

    Roberts, C. W.; Smith, D. L.

    1970-01-01

    Simple, inexpensive drag sphere velocity meter with a zero to 6 ft/sec range measures steady-state flow. When combined with appropriate data acquisition system, it is suited to applications where large numbers of simultaneous measurements are needed for current mapping or velocity profile determination.

  13. Characterization of swallow modulation in response to bolus volume in healthy subjects accounting for catheter diameter.

    Science.gov (United States)

    Ferris, Lara; Schar, Mistyka; McCall, Lisa; Doeltgen, Sebastian; Scholten, Ingrid; Rommel, Nathalie; Cock, Charles; Omari, Taher

    2018-06-01

    Characterization of the pharyngeal swallow response to volume challenges is important for swallowing function assessment. The diameter of the pressure-impedance recording catheter may influence these results. In this study, we captured key physiological swallow measures in response to bolus volume utilizing recordings acquired by two catheters of different diameter. Ten healthy adults underwent repeat investigations with 8- and 10-Fr catheters. Liquid bolus swallows of volumes 2.5, 5, 10, 20, and 30 mL were recorded. Measures indicative of distension, contractility, and flow timing were assessed. Pressure-impedance recordings with pressure-flow analysis were used to capture key distension, contractility, and pressure-flow timing parameters. Larger bolus volumes increased upper esophageal sphincter distension diameter (P < .001) and distension pressures within the hypopharynx and upper esophageal sphincter (P < .05). Bolus flow timing measures were longer, particularly latency of bolus propulsion ahead of the pharyngeal stripping wave (P < .001). Use of a larger-diameter catheter produced higher occlusive pressures, namely upper esophageal sphincter basal pressure (P < .005) and upper esophageal sphincter postdeglutitive pressure peak (P < .001). The bolus volume swallowed changed measurements indicative of distension pressure, luminal diameter, and pressure-flow timing; this is physiologically consistent with swallow modulation to accommodate larger, faster-flowing boluses. Additionally, catheter diameter predominantly affects lumen occlusive pressures. Appropriate physiological interpretation of the pressure-impedance recordings of pharyngeal swallowing requires consideration of the effects of volume and catheter diameter. NA. Laryngoscope, 128:1328-1334, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  14. Study of the operational parameters of crops turbine sprayer (turbo liner on spray quality and diameter of droplets, using image processing

    Directory of Open Access Journals (Sweden)

    F Behzadi Pour

    2017-05-01

    Full Text Available Introduction Today, attention to safety and environmental issues in all sectors in agriculture, industry and services is very important. Chemical poisons play an important role in rapid progress of agricultural products. Every year about 25 to 35 percent of the world's crops are affected by insects, weeds and plant pathogens disappear and this figure would be raised to 80% if no control was applied. Drift problem and its devastating effects are the most important issue which related to users and sprayers manufacturers. Spray drift reduction and improvements in the efficiency of pesticide application processes are global goals. Where ever spraying is applied, drift will be produced and it must be controlled by controlled of the droplet size. The application of these sprayers is the high in the farms (the number of 2303 in Iran. So, this research was carried out to improve the quality of work in these sprayers by studying the droplets diameter and the spray quality index. Materials and Methods The research was conducted at the University of Khouzestan Ramin Agriculture and Natural Resources. Tests were done with 20 m of water sensitive papers at a distance of 2 meters from each other. To evaluate the technical items affecting on drift, an experiment was conducted using a turbo liner sprayer (TURBINA S.A. 800 and the John Deer (JD 3140 tractor. A completely randomized factorial design was applied. By using 3 replications and the factors were spraying pressure applying three levels (10, 25 and 35 bar, the fan speed with two levels (1998 and 2430 rpm and forward speed with two levels (9 and 13.5 km hr-1. The sprayer started the application, spraying a solution of water and tracer (yellow Tartrazine E 102, 15m before the water sensitive papers and then moved over the water sensitive papers. The spraying was continued 15 m after the end of the sampling area. After spraying, sensitive papers were photographed and then volume diameter of 50% (DV50 and

  15. Reduction of noise in the neonatal intensive care unit using sound-activated noise meters.

    Science.gov (United States)

    Wang, D; Aubertin, C; Barrowman, N; Moreau, K; Dunn, S; Harrold, J

    2014-11-01

    To determine if sound-activated noise meters providing direct audit and visual feedback can reduce sound levels in a level 3 neonatal intensive care unit (NICU). Sound levels (in dB) were compared between a 2-month period with noise meters present but without visual signal fluctuation and a subsequent 2 months with the noise meters providing direct audit and visual feedback. There was a significant increase in the percentage of time the sound level in the NICU was below 50 dB across all patient care areas (9.9%, 8.9% and 7.3%). This improvement was not observed in the desk area where there are no admitted patients. There was no change in the percentage of time the NICU was below 45 or 55 dB. Sound-activated noise meters seem effective in reducing sound levels in patient care areas. Conversations may have moved to non-patient care areas preventing a similar change there. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Development and evaluation of an ultrasonic ground water seepage meter.

    Science.gov (United States)

    Paulsen, R J; Smith, C F; O'Rourke, D; Wong, T F

    2001-01-01

    Submarine ground water discharge can influence significantly the near-shore transport and flux of chemicals into the oceans. Quantification of the sources and rates of such discharge requires a ground water seepage meter that provides continuous measurements at high resolution over an extended period of time. An ultrasonic flowmeter has been adapted for such measurements in the submarine environment. Connected to a steel collection funnel, the meter houses two piezoelectric transducers mounted at opposite ends of a cylindrical flow tube. By monitoring the perturbations of fluid flow on the propagation of sound waves inside the flow tube, the ultrasonic meter can measure both forward and reverse fluid flows in real time. Laboratory and field calibrations show that the ultrasonic meter can resolve ground water discharges on the order of 0.1 microm/sec, and it is sufficiently robust for deployment in the field for several days. Data from West Neck Bay, Shelter Island, New York, elucidate the temporal and spatial heterogeneity of submarine ground water discharge and its interplay with tidal loading. A negative correlation between the discharge and tidal elevation was generally observed. A methodology was also developed whereby data for the sound velocity as a function of temperature can be used to infer the salinity and source of the submarine discharge. Independent measurements of electrical conductance were performed to validate this methodology.

  17. Variations in eyeball diameters of the healthy adults.

    Science.gov (United States)

    Bekerman, Inessa; Gottlieb, Paul; Vaiman, Michael

    2014-01-01

    The purpose of the current research was to reevaluate the normative data on the eyeball diameters. Methods. In a prospective cohort study, the CT data of consecutive 250 adults with healthy eyes were collected and analyzed, and sagittal, transverse, and axial diameters of both eyeballs were measured. The data obtained from the left eye and from the right eye were compared. The correlation analysis was performed with the following variables: orbit size, gender, age, and ethnic background. Results. We did not find statistically significant differences correlated with gender of the patients and their age. The right eyeball was slightly smaller than the left one but this difference was statistically insignificant (P = 0.17). We did not find statistically significant differences of the eyeball sizes among the ethnicities we dealt with. Strong correlation was found between the transverse diameter and the width of the orbit (r = 0.88). Conclusion. The size of a human adult eye is approximately 24.2 mm (transverse) × 23.7 mm (sagittal) × 22.0-24.8 mm (axial) with no significant difference between sexes and age groups. In the transverse diameter, the eyeball size may vary from 21 mm to 27 mm. These data might be useful in ophthalmological, oculoplastic, and neurological practice.

  18. Axon diameter mapping in crossing fibers with diffusion MRI

    DEFF Research Database (Denmark)

    Zhang, Hui; Dyrby, Tim B; Alexander, Daniel C

    2011-01-01

    This paper proposes a technique for a previously unaddressed problem, namely, mapping axon diameter in crossing fiber regions, using diffusion MRI. Direct measurement of tissue microstructure of this kind using diffusion MRI offers a new class of biomarkers that give more specific information about...... tissue than measures derived from diffusion tensor imaging. Most existing techniques for axon diameter mapping assume a single axon orientation in the tissue model, which limits their application to only the most coherently oriented brain white matter, such as the corpus callosum, where the single...... model to enable axon diameter mapping in voxels with crossing fibers. We show in simulation that the technique can provide robust axon diameter estimates in a two-fiber crossing with the crossing angle as small as 45 degrees. Using ex vivo imaging data, we further demonstrate the feasibility...

  19. 49 CFR 192.359 - Customer meter installations: Operating pressure.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meter installations: Operating pressure... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.359 Customer meter installations: Operating pressure...

  20. Data acquisition and meter unit based in wifi communication protocol

    Directory of Open Access Journals (Sweden)

    Gerardo Cázarez Ayala

    2012-05-01

    Full Text Available Without doubt, the competitive fast rhythm of the industries is one of the main causes helped bring to the accelerated growth of the electronic technology and the communication. The need to develop new products with a best quality, cheaper and faster as assure and increase the quality of the products in the international markets, requires of new technologies to the metering, monitoring and control of their production processes, of which finality is to improve the processes to guaranteed their products in the market in the less time possible, the best quality and low cost for the final consumer. This work is based in the design and implementation of a Wireless Data Acquisition Unit based in WiFi protocol, which is oriented to meter, monitoring and the control of processes in the industry, commercial and the home automation applications, using one of the wirelessprotocols with the biggest acceptance in the market, with the main objective of to take advantage of the installed physical infrastructure in the place of the application, like industry, company or house. The Unit is based in the RN-131G, a Roving Network company module, which is able to work in stand-alone mode with ultralow power consummation and supporting the IEEE 802.11b/g protocols, in which is possible to achieve transfer rates of up to 11 Mbps and 54 Mbps in /b & /g specifications respectively. Whit this unit is possible to meter up to 5 analogs signals with 14 bits precision and has include a temperature and relative humidity sensors. This unit can meter two digital signals and act mean two digitals outputs, and gas include an USB port for communication and programming tasks.