WorldWideScience

Sample records for two-meter darrieus type

  1. Research on Darrieus-type hydraulic turbine for extra-low head hydropower utilization

    International Nuclear Information System (INIS)

    Furukawa, A; Watanabe, S; Okuma, K

    2012-01-01

    A Darrieus-type turbine has been investigated for extra-low head hydropower utilization. In the present paper, authors'research on Darrieus-type hydraulic turbine is briefly reviewed. The working principle of Darrieus turbine is explained with advantage of its simple structure, at first. Then the fluid-dynamic difference between rotating and linear motions of a blade in a uniform flow is clarified with guiding principle of high performance design of Darrieus turbine. Cavitation problem is also described. Next, effects of duct-casing, consisting of an intake, runner section and draft tube, are discussed and a simplified structure of Darrieus turbine is shown by installing the inlet nozzle. Finally, in the practical use, an adjustment of inlet nozzle section by lowering the inlet nozzle height is proposed when flow rate is varied temporally and seasonally.

  2. Performance Prediction of Darrieus-Type Hydroturbine with Inlet Nozzle Operated in Open Water Channels

    Science.gov (United States)

    Nakashima, K.; Watanabe, S.; Matsushita, D.; Tsuda, S.; Furukawa, A.

    2016-11-01

    Small hydropower is one of the renewable energies and is expected to be effectively used for local supply of electricity. We have developed Darrieus-type hydro-turbine systems, and among them, the Darrieus-turbine with a weir and a nozzle installed upstream of turbine is, so far, in success to obtain more output power by gathering all water into the turbine. However, there can several cases exist, in which installing the weir covering all the flow channel width is unrealistic, and in such cases, the turbine should be put alone in open channels without upstream weir. Since the output power is very small in such a utilization of small hydropower, it is important to derive more power for the cost reduction. In the present study, we parametrically investigate the preferable shape of the inlet nozzle for the Darrieus-type hydroturbine operated in an open flow channel. Experimental investigation is carried out in the open channel in our lab. Tested inlet nozzles are composed of two flat plates with the various nozzle converging angles and nozzle outlet (runner inlet) widths with the nozzle inlet width kept constant. As a result, the turbine with the nozzles having large converging angle and wide outlet width generates higher power. Two-dimensional unsteady numerical simulation is also carried out to qualitatively understand the flow mechanism leading to the better performance of turbine. Since the depth, the width and the flow rate in the real open flow channels are different from place to place and, in some cases from time to time, it is also important to predict the onsite performance of the hydroturbine from the lab experiment at planning stage. One-dimensional stream-tube model is developed for this purpose, in which the Darrieus-type hydroturbine with the inlet nozzle is considered as an actuator-disk modelled based on our experimental and numerical results.

  3. Design and fabrication of a low-cost Darrieus vertical-axis wind-turbine system, volume 2

    Science.gov (United States)

    1983-03-01

    The fabrication, installation, and checkout of 100-kW 17 meter vertical axis wind turbines is described. Turbines are Darrieus-type VAWIs with rotors 17 meters and 25.15 meters in height. They can produce 100 kW of electric power at a cost of energy as low as 3 cents per kWh, in an 18-mph wind regime using 12% annualized costs. Four turbines were produced; three are installed and are operable. Contract results are documented.

  4. Hybrid Configuration of Darrieus and Savonius Rotors for Stand-alone Power Systems

    Science.gov (United States)

    Wakui, Tetsuya; Tanzawa, Yoshiaki; Hashizume, Takumi; Nagao, Toshio

    The suitable hybrid configuration of Darrieus lift-type and Savonius drag-type rotors for stand-alone wind turbine-generator systems is discussed using our dynamic simulation model. Two types of hybrid configurations are taken up: Type-A installs the Savonius rotor inside the Darrieus rotor and Type-B installs the Savonius rotor outside the Darrieus rotor. The computed results of the output characteristics and the dynamic behaviors of the system operated at the maximum power coefficient points show that Type-A, which has fine operating behavior to wind speed changes and can be compactly designed because of a shorter rotational shaft, is an effective way for self-controlled stand-alone small-scale systems.

  5. Straight-bladed Darrieus wind turbines - A protagonist's view

    Science.gov (United States)

    Migliore, P. G.

    The technology development and market penetration of Darrieus and propeller-type wind turbines is addressed. Important characteristics of competing configurations are compared, and it is claimed that aerodynamic efficiency is not a distinguishing feature. Advantages of the Darrieus machine include omni-directionality and self-limitation, but propeller types require less rotor length per unit swept area. It is argued that the straight-bladed Darrieus is much simpler than the curved-bladed and should be capable of comparable aerodynamic efficiency. Some of the problems of structural design, as well as blade induced drag losses and support-arm counter torque, diminish rapidly as machine size is increased. Taper ratio has similar beneficial effects.

  6. Design and fabrication of a low-cost Darrieus vertical-axis wind-turbine system, phase 2. Volume 3: Design, fabrication, and site drawing

    Science.gov (United States)

    1983-03-01

    The design, fabrication, and site drawings associated with fabrication, installation, and check out of 100 kW 17 meter Vertical Axis Wind Turbines (VAWTs) were reported. The turbines are Darrieus type VAWTs with rotors 17 meters in diameter and 25.15 meters in height. They can produce 100 kW of electric power at a cost of energy as low as 3 cents per kWh, in an 18 mph wind regime using 12% annualized costs. Four turbines are produced, three are installed and operable.

  7. Aerodynamic analysis of the Darrieus rotor including secondary effects

    Science.gov (United States)

    Paraschivoiu, I.; Delclaux, F.; Fraunie, P.; Beguier, C.

    1983-10-01

    An aerodynamic analysis is made of two variants of the two-actuator-disk theory for modeling the Darrieus wind turbine. The double-multiple-streamtube model with constant and variable interference factors, including secondary effects, is examined for a Darrieus rotor. The influence of the secondary effects, namely, the blade geometry and profile type, the rotating tower, and the presence of struts and aerodynamic spoilers, is relatively significant, especially at high tip-speed ratios. Variation of the induced velocity as a function of the azimuthal angle allows a more accurate calculation of the aerodynamic loads on the downwind zone of the rotor with respect to the assumed constant interference factors. The theoretical results were compared with available experimental data for the Magdalen Islands wind turbine and Sandia-type machines (straight-line/circular-arc shape).

  8. Aerodynamic performance prediction of Darrieus-type wind turbines

    Directory of Open Access Journals (Sweden)

    Ion NILĂ

    2010-06-01

    Full Text Available The prediction of Darrieus wind turbine aerodynamic performances provides the necessarydesign and operational data base related to the wind potential. In this sense it provides the type ofturbine suitable to the area where it is to be installed. Two calculation methods are analyzed for arotor with straight blades. The first one is a global method that allows an assessment of the turbinenominal power by a brief calculation. This method leads to an overestimation of performances. Thesecond is the calculation method of the gust factor and momentum which deals with the pale as beingcomposed of different elements that don’t influence each other. This method, developed based on thetheory of the turbine blades, leads to values close to the statistical data obtained experimentally. Thevalues obtained by the calculation method of gust factor - momentum led to the concept of a Darrieusturbine, which will be tested for different wind values in the INCAS subsonic wind tunnel.

  9. Aeroelastic stability analysis of a Darrieus wind turbine

    Science.gov (United States)

    Popelka, D.

    1982-02-01

    An aeroelastic stability analysis was developed for predicting flutter instabilities on vertical axis wind turbines. The analytical model and mathematical formulation of the problem are described as well as the physical mechanism that creates flutter in Darrieus turbines. Theoretical results are compared with measured experimental data from flutter tests of the Sandia 2 Meter turbine. Based on this comparison, the analysis appears to be an adequate design evaluation tool.

  10. Aeroelastic stability analysis of a Darrieus wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Popelka, D.

    1982-02-01

    An aeroelastic stability analysis has been developed for predicting flutter instabilities on vertical axis wind turbines. The analytical model and mathematical formulation of the problem are described as well as the physical mechanism that creates flutter in Darrieus turbines. Theoretical results are compared with measured experimental data from flutter tests of the Sandia 2 Meter turbine. Based on this comparison, the analysis appears to be an adequate design evaluation tool.

  11. Cavitating behaviour analysis of Darrieus-type cross flow water turbines

    International Nuclear Information System (INIS)

    Aumelas, V; Pellone, C; MaItre, T

    2010-01-01

    The aim of this paper is to study the cavitating behaviour of bare Darrieus-type turbines. For that, the RANS code CAVKA, has been used. Under non-cavitating conditions, the power coefficient and the thrusts calculated with CAVKA are compared to experimental values obtained in the LEGI hydrodynamic tunnel. Under cavitating conditions, for several cavitation numbers, the numerical power coefficients and vapour structures are compared to experimental ones. Different blade profiles and camber lines are also studied for non-cavitating and cavitating conditions.

  12. Variable geometry Darrieus wind machine

    Science.gov (United States)

    Pytlinski, J. T.; Serrano, D.

    1983-08-01

    A variable geometry Darrieus wind machine is proposed. The lower attachment of the blades to the rotor can move freely up and down the axle allowing the blades of change shape during rotation. Experimental data for a 17 m. diameter Darrieus rotor and a theoretical model for multiple streamtube performance prediction were used to develop a computer simulation program for studying parameters that affect the machine's performance. This new variable geometry concept is described and interrelated with multiple streamtube theory through aerodynamic parameters. The computer simulation study shows that governor behavior of a Darrieus turbine can not be attained by a standard turbine operating within normally occurring rotational velocity limits. A second generation variable geometry Darrieus wind turbine which uses a telescopic blade is proposed as a potential improvement on the studied concept.

  13. Variable Pitch Darrieus Water Turbines

    Science.gov (United States)

    Kirke, Brian; Lazauskas, Leo

    In recent years the Darrieus wind turbine concept has been adapted for use in water, either as a hydrokinetic turbine converting the kinetic energy of a moving fluid in open flow like an underwater wind turbine, or in a low head or ducted arrangement where flow is confined, streamtube expansion is controlled and efficiency is not subject to the Betz limit. Conventional fixed pitch Darrieus turbines suffer from two drawbacks, (i) low starting torque and (ii) shaking due to cyclical variations in blade angle of attack. Ventilation and cavitation can also cause problems in water turbines when blade velocities are high. Shaking can be largely overcome by the use of helical blades, but these do not produce large starting torque. Variable pitch can produce high starting torque and high efficiency, and by suitable choice of pitch regime, shaking can be minimized but not entirely eliminated. Ventilation can be prevented by avoiding operation close to a free surface, and cavitation can be prevented by limiting blade velocities. This paper summarizes recent developments in Darrieus water turbines, some problems and some possible solutions.

  14. Assessment of C-Type Darrieus Wind Turbine Under Low Wind Speed Condition

    Science.gov (United States)

    Misaran, M. S.; Rahman, Md. M.; Muzammil, W. K.; Ismail, M. A.

    2017-07-01

    Harvesting wind energy in in a low wind speed region is deem un-economical if not daunting task. Study shows that a minimum cut in speed of 3.5 m/s is required to extract a meaningful wind energy for electricity while a mean speed of 6 m/s is preferred. However, in Malaysia the mean speed is at 2 m/s with certain potential areas having 3 m/s mean speed. Thus, this work aims to develop a wind turbine that able to operate at lower cut-in speed and produce meaningful power for electricity generation. A C-type Darrieus blade is selected as it shows good potential to operate in arbitrary wind speed condition. The wind turbine is designed and fabricated in UMS labs while the performance of the wind turbine is evaluated in a simulated wind condition. Test result shows that the wind turbine started to rotate at 1 m/s compared to a NACA 0012 Darrieus turbine that started to rotate at 3 m/s. The performance of the turbine shows that it have good potential to be used in an intermittent arbitrary wind speed condition as well as low mean wind speed condition.

  15. Design and fabrication of a low cost Darrieus vertical axis wind turbine system: Phase 2, volume 1: Executive summary

    Science.gov (United States)

    1983-03-01

    Described is the successful fabrication, installation, and checkout of 100 kW 17 meter Vertical Axis Wind Turbines (VAWTs). The turbines are Darrieus-type VAWTs with rotors 17 meters (55 feet) in diameter and 25.15 meters (83 feet) in height. They can produce 100 kW of electric power at a cost of energy as low as 3 cents per kWh, in an 18 mph wind regime using 12% annualized costs. Four turbines were produced; three are installed and are operable at: (1) Wind Systems Test Center, Rocky Flats, Colorado; (2) the US Department of Agriculture Conservation and Production Research Center at Bushland, Texas; and (3) Tisbury Water Authority, Vineyard Haven, Massachusetts, on the island of Martha's Vineyard. The fourth turbine is stored at Bushland, Texas awaiting selection of an erection site.

  16. Wind turbine design : with emphasis on Darrieus concept

    Energy Technology Data Exchange (ETDEWEB)

    Paraschivoiu, I. [Ecole Polytechnique, Montreal, PQ (Canada)

    2002-07-01

    This book described software applications designed to model the aerodynamic performance of the Darrieus vertical-axis wind turbine. The book also provided a comprehensive review of current vertical-axis wind turbine (VAWT) technology, and discussed recent advances in understanding the physics of flow associated with the Darrieus type of turbine. The principal theories and aerodynamic models for calculating the performance of the turbines were presented, as well as results from experimental data derived from prototypes as well as laboratory measurements. The book was divided into 10 chapters: (1) wind definition and characteristics; (2) a review of the Madaras rotor concept along with an introduction to vortex modelling; (3) an introduction to the geometry of the Darrieus rotor; (4) a single streamtube model; (5) dynamic-stall phenomenon and numerical simulations; (6) double actuator risk theory; (7) details of water channel experiments; (8) modelling of turbine components; (9) wind turbine design parameters; and (10) issues related to socio-economic and environmental impacts. refs., tabs., figs.

  17. Improved double-multiple streamtube model for the Darrieus-type vertical axis wind turbine

    Science.gov (United States)

    Berg, D. E.

    Double streamtube codes model the curved blade (Darrieus-type) vertical axis wind turbine (VAWT) as a double actuator fish arrangement (one half) and use conservation of momentum principles to determine the forces acting on the turbine blades and the turbine performance. Sandia National Laboratories developed a double multiple streamtube model for the VAWT which incorporates the effects of the incident wind boundary layer, nonuniform velocity between the upwind and downwind sections of the rotor, dynamic stall effects and local blade Reynolds number variations. The theory underlying this VAWT model is described, as well as the code capabilities. Code results are compared with experimental data from two VAWT's and with the results from another double multiple streamtube and a vortex filament code. The effects of neglecting dynamic stall and horizontal wind velocity distribution are also illustrated.

  18. CFD analysis of a Darrieus wind turbine

    Science.gov (United States)

    Niculescu, M. L.; Cojocaru, M. G.; Pricop, M. V.; Pepelea, D.; Dumitrache, A.; Crunteanu, D. E.

    2017-07-01

    The Darrieus wind turbine has some advantages over the horizontal-axis wind turbine. Firstly, its tip speed ratio is lower than that of the horizontal-axis wind turbine and, therefore, its noise is smaller, privileging their placement near populated areas. Secondly, the Darrieus wind turbine does needs no orientation mechanism with respect to wind direction in contrast to the horizontal-axis wind turbine. However, the efficiency of the Darrieus wind turbine is lower than that of the horizontal-axis wind turbine since its aerodynamics is much more complex. With the advances in computational fluids and computers, it is possible to simulate the Darrieus wind turbine more accurately to understand better its aerodynamics. For these reasons, the present papers deals with the computational aerodynamics of a Darrieus wind turbine applying the state of the art of CFD methods (anisotropic turbulence models, transition from laminar to turbulent, scale adaptive simulation) to better understand its unsteady behavior.

  19. Adjoint Airfoil Optimization of Darrieus-Type Vertical Axis Wind Turbine

    Science.gov (United States)

    Fuchs, Roman; Nordborg, Henrik

    2012-11-01

    We present the feasibility of using an adjoint solver to optimize the torque of a Darrieus-type vertical axis wind turbine (VAWT). We start with a 2D cross section of a symmetrical airfoil and restrict us to low solidity ratios to minimize blade vortex interactions. The adjoint solver of the ANSYS FLUENT software package computes the sensitivities of airfoil surface forces based on a steady flow field. Hence, we find the torque of a full revolution using a weighted average of the sensitivities at different wind speeds and angles of attack. The weights are computed analytically, and the range of angles of attack is given by the tip speed ratio. Then the airfoil geometry is evolved, and the proposed methodology is evaluated by transient simulations.

  20. Georges Darrieus, inventor of vertical axis wind-turbines; Georges Darrieus, pere des eoliennes a axe vertical

    Energy Technology Data Exchange (ETDEWEB)

    Rogier, E.

    2000-10-01

    This article is a short biography of the French man Georges Darrieus (1888-1979) who invented the vertical wind turbine. G.Darrieus can be considered as the first industrial researcher in France, he was a double authority in sciences and in industry machinery. He presented more than 50 patterns and wrote about 700 scientific and technological articles.

  1. Investigations on the Effect of Radius Rotor in Combined Darrieus-Savonius Wind Turbine

    Directory of Open Access Journals (Sweden)

    Kaprawi Sahim

    2018-01-01

    Full Text Available Renewable sources of energy, abundant in availability, are needed to be exploited with adaptable technology. For wind energy, the wind turbine is very well adapted to generate electricity. Among the different typologies, small scale Vertical Axis Wind Turbines (VAWT present the greatest potential for off-grid power generation at low wind speeds. The combined Darrieus-Savonius wind turbine is intended to enhance the performance of the Darrieus rotor in low speed. In combined turbine, the Savonius buckets are always attached at the rotor shaft and the Darrieus blades are installed far from the shaft which have arm attaching to the shaft. A simple combined turbine offers two rotors on the same shaft. The combined turbine that consists of two Darrieus and Savonius blades was tested in wind tunnel test section with constant wind velocity and its performance was assessed in terms of power and torque coefficients. The study gives the effect of the radius ratio between Savonius and Darrieus rotor on the performance of the turbine. The results show that there is a significant influence on the turbine performance if the radius ratio was changed.

  2. Energy characteristics of Darrieus rotor ( review)

    Science.gov (United States)

    Gorelov, D. N.

    2010-09-01

    Presented below is the review of the results of experimental studies of energy characteristics of Darrieus rotor with vertical rotation axis. Influence of main geometry parameters of the rotor on its energy characteristics has been analyzed. It is shown that Darrieus rotor may have the higher level of energy characteristics than the best propeller wind turbines.

  3. Effectiveness of two-dimensional CFD simulations for Darrieus VAWTs: a combined numerical and experimental assessment

    International Nuclear Information System (INIS)

    Bianchini, Alessandro; Balduzzi, Francesco; Bachant, Peter; Ferrara, Giovanni; Ferrari, Lorenzo

    2017-01-01

    Highlights: • 2D CFD simulations compared to experimental tow-tank data on the RVAT test model. • The use of CFD with open-field-like boundaries is suggested. • A reliable estimation of the turbine performance and the wake structure is obtained. • The transitional turbulence model is recommended for low TSRs and/or small rotors. • The wake analysis identified the main vortical structures generated by the blades. - Abstract: Thanks to the continuous improvement of calculation resources, computational fluid dynamics (CFD) is expected to provide in the next few years a cost-effective and accurate tool to improve the understanding of the unsteady aerodynamics of Darrieus wind turbines. This rotor type is in fact increasingly welcome by the wind energy community, especially in case of small size applications and/or non-conventional installation sites. In the present study, unique tow tank experimental data on the performance curve and the near-wake structure of a Darrieus rotor were used as a benchmark to validate the effectiveness of different CFD approaches. In particular, a dedicated analysis is provided to assess the suitability, the effectiveness and the future prospects of simplified two-dimensional (2D) simulations. The correct definition of the computational domain, the selection of the turbulence models and the correction of simulated data for the parasitic torque components are discussed in this study. Results clearly show that, (only) if properly set, two-dimensional CFD simulations are able to provide - with a reasonable computational cost - an accurate estimation of the turbine performance and also quite reliably describe the attended flow-field around the rotor and its wake.

  4. An Experimental Study on the Darrieus-Savonius Turbine for the Tidal Current Power Generation

    Science.gov (United States)

    Kyozuka, Yusaku

    The Darrieus turbine is popular for tidal current power generation in Japan. It is simple in structure with straight wings rotating around a vertical axis, so that it has no directionality against the motion of tidal flow which changes its direction twice a day. However, there is one defect in the Darrieus turbine; its small starting torque. Once it stops, a Darrieus turbine is hard to re-start until a fairly fast current is exerted on it. To improve the starting torque of the Darrieus turbine used for tidal power generation, a hybrid turbine, composed of a Darrieus turbine and a Savonius rotor is proposed. Hydrodynamic characteristics of a semi-circular section used for the Savonius bucket were measured in a wind tunnel. The torque of a two bucket Savonius rotor was measured in a circulating water channel, where four different configurations of the bucket were compared. A combined Darrieus and Savonius turbine was tested in the circulating water channel, where the effect of the attaching angle between Darrieus wing and Savonius rotor was studied. Finally, power generation experiments using a 48 pole electric generator were conducted in a towing tank and the power coefficients were compared with the results of experiments obtained in the circulating water channel.

  5. Numerical and experimental analysis of a darrieus-type cross flow water turbine in bare and shrouded configurations

    International Nuclear Information System (INIS)

    Roa, A M; Aumelas, V; MaItre, T; Pellone, C

    2010-01-01

    The aim of this paper is to present the results of the analysis of a Darrieus-type cross flow water turbine in bare and shrouded configurations. Numerical results are compared to experimental data and differences found in values are also highlighted. The benefit of the introduction of a channelling device, which generates an efficiency increment factor varying from 2 to 5, depending on the configuration, is discussed.

  6. Computational fluid dynamics analysis of a twisted airfoil shaped two-bladed H-Darrieus rotor made from fibreglass reinforced plastic (FRP)

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Rajat; Roy, Sukanta; Biswas, Agnimitra [Department of Mechanical Engineering, National Institute of Technology, Silchar, Assam, 788010 (India)

    2010-07-01

    H-Darrieus rotor is a lift type device having two to three blades designed as airfoils. The blades are attached vertically to the central shaft through support arms. The support to vertical axis helps the rotor maintain its shape. In this paper, Computational Fluid Dynamics (CFD) analysis of an airfoil shaped two-bladed H-Darrieus rotor using Fluent 6.2 software was performed. Based on the CFD results, a comparative study between experimental and computational works was carried out. The H-Darrieus rotor was 20cm in height, 5cm in chord and twisted with an angle of 30{sup o} at the trailing end. The blade material of rotor was Fiberglass Reinforced Plastic (FRP). The experiments were earlier conducted in a subsonic wind tunnel for various height-to-diameter (H/D) ratios. A two dimensional computational modeling was done with the help of Gambit tool using unstructured grid. Realistic boundary conditions were provided for the model to have synchronization with the experimental conditions. Two dimensional steady-state segregated solver with absolute velocity formulation and cell based grid was considered, and a standard k-epsilon viscous model with standard wall functions was chosen. A first order upwind discretization scheme was adopted for pressure velocity coupling of the flow. The inlet velocities and rotor rotational speeds were taken from the experimental results. From the computational analysis, power coefficient (Cp) and torque coefficient (Ct) values at ten different H/D ratios namely 0.85, 1.0, 1.10, 1.33, 1.54, 1.72, 1.80, 1.92, 2.10 and 2.20 were calculated in order to predict the performances of the twisted H-rotor. The variations of Cp and Ct with tip speed ratios were analyzed and compared with the experimental results. The standard deviations of computational Cp and Ct from experimental Cp and Ct were obtained. From the computational analysis, the highest values of Cp and Ct were obtained at H/D ratios of 1.0 and 1.54 respectively. The deviation of

  7. Dynamical study of the Darrieus-type turbine runners by using finite element method; Estudo da dinamica de turbinas hidraulicas mare-motrizes do tipo Darrieus atraves do metodo dos elementos finitos

    Energy Technology Data Exchange (ETDEWEB)

    Sena, Manoel Jose dos Santos; Mesquita, Andre Luiz Amarante [Para Univ., Belem, PA (Brazil). Dept. de Engenharia Mecanica. Grupo de Turbomaquinas]. E-mail: gtdem@ufpa.br

    2000-07-01

    The purpose of this work is describe the implementation of a finite element model for dynamic response analysis of Darrieus-type turbine runners. A fluid-structure coupling is be used to put in evidence some aspects of the rotor-water interaction. The rotating system fixed to the rotor will be used when writing the equations governing the system. A procedure using the ANSYS Parametric Design Language is discussed and some results obtained for the free-free configuration are shown. (author)

  8. Aerodynamic models for a Darrieus wind turbine

    Science.gov (United States)

    Fraunie, P.; Beguier, C.; Paraschivoiu, I.; Delclaux, F.

    1982-11-01

    Various models proposed for the aerodynamics of Darrieus wind turbines are reviewed. The magnitude of the L/D ratio for a Darrieus rotor blade is dependent on the profile, the Re, boundary layer characteristics, and the three-dimensional flow effects. The aerodynamic efficiency is theoretically the Betz limit, and the interference of one blade with another is constrained by the drag force integrated over all points on the actuator disk. A single streamtube model can predict the power available in a Darrieus, but the model lacks definition of the flow structure and the cyclic stresses. Techniques for calculating the velocity profiles and the consequent induced velocity at the blades are presented. The multiple streamtube theory has been devised to account for the repartition of the velocity in the rotor interior. The model has been expanded as the double multiple streamtube theory at Sandia Laboratories. Futher work is necessary, however, to include the effects of dynamic decoupling at high rotation speeds and to accurately describe blade behavior.

  9. A vortex model for Darrieus turbine using finite element techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ponta, Fernando L. [Universidad de Buenos Aires, Dept. de Electrotecnia, Grupo ISEP, Buenos Aires (Argentina); Jacovkis, Pablo M. [Universidad de Buenos Aires, Dept. de Computacion and Inst. de Calculo, Buenos Aires (Argentina)

    2001-09-01

    Since 1970 several aerodynamic prediction models have been formulated for the Darrieus turbine. We can identify two families of models: stream-tube and vortex. The former needs much less computation time but the latter is more accurate. The purpose of this paper is to show a new option for modelling the aerodynamic behaviour of Darrieus turbines. The idea is to combine a classic free vortex model with a finite element analysis of the flow in the surroundings of the blades. This avoids some of the remaining deficiencies in classic vortex models. The agreement between analysis and experiment when predicting instantaneous blade forces and near wake flow behind the rotor is better than the one obtained in previous models. (Author)

  10. Numerical investigation of aerodynamic performance of darrieus wind turbine based on the magnus effect

    OpenAIRE

    L Khadir; H Mrad

    2016-01-01

    The use of several developmental approaches is the researchers’ major preoccupation with the DARRIEUS wind turbine. This paper presents the first approach and results of a wide computational investigation on the aerodynamics of a vertical axis DARRIEUS wind turbine based on the MAGNUS effect. Consequently, wind tunnel tests were carried out to ascertain overall performance of the turbine and two-dimensional unsteady computational fluid dynamics (CFD) models were generated to help understand t...

  11. The VGOT Darrieus wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Ponta, F.L.; Otero, A.D.; Lago, L. [University of Buenos Aires (Argentina). College of Engineering

    2004-07-01

    We present the actual state of development of a non-conventional new vertical-axis wind turbine. The concepts introduced here involve the constructive aspects of variable-geometry oval-trajectory (VGOT) Darrieus wind turbines. The key feature of a VGOT machine is that each blade slides over rails mounted on a wagon instead of rotating around a central vertical axis. Each wagon contains its own electrical generation system coupled to the power-wheels and the electricity is collected by a classical third rail system. The VGOT concept allows increasing the area swept by the blades, and hence the power output of the installation, without the structural problems and the low rotational speed associated with a classical Darrieus rotor of large diameter. We also propose some engineering solutions for the VGOT design and present a brief economic analysis of the feasibility of the project. (author)

  12. Darrieus wind-turbine airfoil configurations

    Science.gov (United States)

    Migliore, P. G.; Fritschen, J. R.

    1982-06-01

    The purpose was to determine what aerodynamic performance improvement, if any, could be achieved by judiciously choosing the airfoil sections for Darrieus wind turbine blades. Ten different airfoils, having thickness to chord ratios of twelve, fifteen and eighteen percent, were investigated. Performance calculations indicated that the NACA 6-series airfoils yield peak power coefficients at least as great as the NACA. Furthermore, the power coefficient-tip speed ratio curves were broader and flatter for the 6-series airfoils. Sample calculations for an NACA 63 sub 2-015 airfoil showed an annual energy output increase of 17 to 27% depending upon rotor solidity, compared to an NACA 0015 airfoil. An attempt was made to account for the flow curvature effects associated with Darrieus turbines by transforming the NACA 63 sub 2-015 airfoil to an appropriate shape.

  13. Streamtube expansion effects on the Darrieus wind turbine

    Science.gov (United States)

    Paraschivoiu, I.; Fraunie, P.; Beguier, C.

    1985-04-01

    The purpose of the work described in this paper was to determine the aerodynamic loads and performance of a Darrieus wind turbine by including the expansion effects of the streamtubes through the rotor. The double-multiple streamtube model with variable interference factors was used to estimate the induced velocities with a modified CARDAAV computer code. Comparison with measured data and predictions shows that the stream-tube expansion effects are relatively significant at high tip-speed ratios, allowing a more realistic modeling of the upwind/downwind flowfield asymmetries inherent in the Darrieus rotor.

  14. Observations of dynamic stall on Darrieus wind turbine blades

    Energy Technology Data Exchange (ETDEWEB)

    Fujisawa, N.; Shibuya, S. [Department of Mechanical and Production Engineering, Niigata University, 8050 Ikarashi 2, 950-2181 Niigata (Japan)

    2001-02-01

    Flow field around a Darrieus wind turbine blade in dynamic stall is studied by flow visualization and particle image velocimetry (PIV) measurement in stationary and rotating frames of reference. The experiment is carried out using the small-scale Darrieus wind turbine in a water tunnel. The unsteady nature of the dynamic stall observed by the flow visualization is quantitatively reproduced in the instantaneous velocity distributions by PIV measurement, which describes the successive shedding of two pairs of stall vortices from the blade moving upstream. The mechanism of dynamic stall is due to the successive generation of separation on the inner surface of the blade followed by the formation of roll-up vortices from the outer surface. Although the qualitative nature of the dynamic stall is independent of the tip-speed ratios, the blade angle for stall appearance and the growth rate of the stall vortices are influenced by the change in tip-speed ratios.

  15. 2D Numerical Simulation and Sensitive Analysis of H-Darrieus Wind Turbine

    Directory of Open Access Journals (Sweden)

    Seyed Mohammad E. Saryazdi

    2018-02-01

    Full Text Available Recently, a lot of attention has been devoted to the use of Darrieus wind turbines in urban areas. The aerodynamics of a Darrieus turbine are very complex due to dynamic stall and changing forces on the turbine triggered by changing horizontal angles. In this study, the aerodynamics of H-rotor vertical axis wind turbine (VAWT has been studied using computational fluid dynamics via two different turbulence models. Shear stress transport (SST k-ω turbulence model was used to simulate a 2D unsteady model of the H-Darrieus turbine. In order to complete this simulation, sensitivity analysis of the effective turbine parameters such as solidity factor, airfoil shape, wind velocity and shaft diameter were done. To simulate the flow through the turbine, a 2D simplified computational domain has been generated. Then fine mesh for each case consisting of different turbulence models and dimensions has been generated. Each mesh in this simulation dependent on effective parameters consisted of domain size, mesh quality, time step and total revolution. The sliding mesh method was applied to evaluate the unsteady interaction between the stationary and rotating components. Previous works just simulated turbine, while in our study sensitivity analysis of effective parameters was done. The simulation results closely match the experimental data, providing an efficient and reliable foundation to study wind turbine aerodynamics. This also demonstrates computing the best value of the effective parameter. The sensitivity analysis revealed best value of the effective parameter that could be used in the process of designing turbine. This work provides the first step in developing an accurate 3D aerodynamic modeling of Darrieus wind turbines. Article History: Received :August 19th 2017; Received: December 15th 2017; Accepted: Januari 14th 2018; Available online How to Cite This Article: Saryazdi, S. M. E. and Boroushaki, M. (2018 2D Numerical Simulation and Sensitive

  16. Flow widening through a Darrieus wind turbine - Theory and experiment

    Science.gov (United States)

    Comolet, R.; Harajli, I.; Mercier Des Rochettes, P.; Yeznasni, A.

    1982-11-01

    A two-dimensional multiple stream tube model is developed for the air flow through a Darrieus wind turbine. The model is configured to account for the widening of the flux tubes as they cross the interior of the actuator disk. Note is made of the lateral broadening of the flow as it moves through the area, leaving a turbulent wake. A relation is defined between the variation in the kinetic energy of the flow and the aerodynamic forces acting on the blades. The global efficiency and the power output of the machine are calculated. Experimental results are reported for a machine equipped with two NACA 0015 blades, each 110 cm long and with a 10 cm chord. The Darrieus had a 1 m diam and was tested in a wind tunnel at wind speeds of 0-18 m/sec. Soap bubbles inflated with He were used for visualization. Power output was found to match prediction. The model is recommended for use in calculating the forces acting on the machine and studying vibration and fatigue causative mechanisms.

  17. Darrieus rotor aerodynamics

    Science.gov (United States)

    Klimas, P. C.

    1982-05-01

    A summary of the progress of modeling the aerodynamic effects on the blades of a Darrieus wind turbine is presented. Interference is discussed in terms of blade/blade wake interaction and improvements in single and multiple stream tube models, of vortex simulations of blades and their wakes, and a hybrid momentum/vortex code to combine fast computation time with interference-describing capabilities. An empirical model has been developed for treating the properties of dynamic stall such as airfoil geometry, Reynolds number, reduced frequency, angle-of-attack, and Mach number. Pitching circulation has been subjected to simulation as potential flow about a two-dimensional flat plate, along with applications of the concepts of virtual camber and virtual incidence, with a cambered airfoil operating in a rectilinear flowfield. Finally, a need to develop a loading model suitable for nonsymmetrical blade sections is indicated, as well as blade behavior in a dynamic, curvilinear regime.

  18. Aerodynamic loads and rotor performance for the Darrieus wind turbines

    Science.gov (United States)

    Paraschivoiu, I.

    1981-12-01

    Aerodynamic blade loads and rotor performance are studied for the Darrieus windmill by using a double-multiple streamtube model. The Darrieus is represented as a pair of actuator disks in tandem at each level of the rotor, with upstream and downstream half-cycles. An equilibrium velocity exists in the center plane, and the upwind velocity is higher than the downwind velocity; lift and drag coefficients are calculated from the Reynolds number and the local angle of attack. Half-rotor torque and power are found by averaging the contributions from each streamtube at each position of the rotor in the upwind cycle. An example is provided for a 17 m Darrieus employing NACA blades. While the method is found to be suitable for predicting blade and rotor performance, the need to incorporate the effects of dynamic stall in the model is stressed as a means to improve accuracy.

  19. Numerical investigation on the flow and power of small-sized multi-bladed straight Darrieus wind turbine

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Straight Darrieus wind turbine has attractive characteristics such as the ability to accept wind from random direction and easy installation and maintenance. But its aerodynamic performance is very complicated, especially for the existence of dynamic stall. How to get better aerodynamic performance arouses lots of interests in the design procedure of a straight Darrieus wind turbine. In this paper, mainly the effects of number of blades and tip speed ratio are discussed. Based on the numerical investigation, an assumed asymmetric straight Darrieus wind turbine is proposed to improve the averaged power coefficient. As to the numerical method, the flow around the turbine is simulated by solving the 2D unsteady Navier-Stokes equation combined with continuous equation. The time marching method on a body-fitted coordinate system based on MAC (Marker-and-Cell) method is used. O-type grid is generated for the whole calculation domain. The characteristics of tangential and normal force are discussed related with dynamic stall of the blade. Averaged power coefficient per period of rotating is calculated to evaluate the eligibility of the turbine.

  20. On the wake of a Darrieus turbine

    Science.gov (United States)

    Base, T. E.; Phillips, P.; Robertson, G.; Nowak, E. S.

    1981-01-01

    The theory and experimental measurements on the aerodynamic decay of a wake from high performance vertical axis wind turbine are discussed. In the initial experimental study, the wake downstream of a model Darrieus rotor, 28 cm diameter and a height of 45.5 cm, was measured in a Boundary Layer Wind Tunnel. The wind turbine was run at the design tip speed ratio of 5.5. It was found that the wake decayed at a slower rate with distance downstream of the turbine, than a wake from a screen with similar troposkein shape and drag force characteristics as the Darrieus rotor. The initial wind tunnel results indicated that the vertical axis wind turbines should be spaced at least forty diameters apart to avoid mutual power depreciation greater than ten per cent.

  1. Scale Adaptive Simulation Model for the Darrieus Wind Turbine

    DEFF Research Database (Denmark)

    Rogowski, K.; Hansen, Martin Otto Laver; Maroński, R.

    2016-01-01

    Accurate prediction of aerodynamic loads for the Darrieus wind turbine using more or less complex aerodynamic models is still a challenge. One of the problems is the small amount of experimental data available to validate the numerical codes. The major objective of the present study is to examine...... the scale adaptive simulation (SAS) approach for performance analysis of a one-bladed Darrieus wind turbine working at a tip speed ratio of 5 and at a blade Reynolds number of 40 000. The three-dimensional incompressible unsteady Navier-Stokes equations are used. Numerical results of aerodynamic loads...

  2. The effect of solidity on the performance of H-rotor Darrieus turbine

    International Nuclear Information System (INIS)

    Hassan, S. M. Rakibul; Ali, Mohammad; Islam, Md. Quamrul

    2016-01-01

    Utilization of wind energy has been investigated for a long period of time by different researchers in different ways. Out of which, the Horizontal Axis Wind Turbine and the Vertical Axis Wind Turbine have now advanced design, but still there is scope to improve their efficiency. The Vertical Axis Wind Turbine (VAWT) has the advantage over Horizontal Axis Wind Turbine (HAWT) for working on omnidirectional air flow without any extra control system. A modified H-rotor Darrieus type VAWT is analysed in this paper, which is a lift based wind turbine. The effect of solidity (i.e. chord length, no. of blades) on power coefficient (C_P) of H-rotor for different tip speed ratios is numerically investigated. The study is conducted using time dependent RANS equations using SST k-ω model. SIMPLE scheme is used as pressure-velocity coupling and in all cases, the second order upwind discretization scheme is chosen for getting more accurate solution. In results, different parameters are compared, which depict the performance of the modified H-rotor Darrieus type VAWT. Double layered H-rotor having inner layer blades with longer chord gives higher power coefficient than those have inner layer blades with smaller chord.

  3. The effect of solidity on the performance of H-rotor Darrieus turbine

    Science.gov (United States)

    Hassan, S. M. Rakibul; Ali, Mohammad; Islam, Md. Quamrul

    2016-07-01

    Utilization of wind energy has been investigated for a long period of time by different researchers in different ways. Out of which, the Horizontal Axis Wind Turbine and the Vertical Axis Wind Turbine have now advanced design, but still there is scope to improve their efficiency. The Vertical Axis Wind Turbine (VAWT) has the advantage over Horizontal Axis Wind Turbine (HAWT) for working on omnidirectional air flow without any extra control system. A modified H-rotor Darrieus type VAWT is analysed in this paper, which is a lift based wind turbine. The effect of solidity (i.e. chord length, no. of blades) on power coefficient (CP) of H-rotor for different tip speed ratios is numerically investigated. The study is conducted using time dependent RANS equations using SST k-ω model. SIMPLE scheme is used as pressure-velocity coupling and in all cases, the second order upwind discretization scheme is chosen for getting more accurate solution. In results, different parameters are compared, which depict the performance of the modified H-rotor Darrieus type VAWT. Double layered H-rotor having inner layer blades with longer chord gives higher power coefficient than those have inner layer blades with smaller chord.

  4. H-Darrieus Wind Turbine with Blade Pitch Control

    Directory of Open Access Journals (Sweden)

    I. Paraschivoiu

    2009-01-01

    Full Text Available A procedure for computing the optimal variation of the blades' pitch angle of an H-Darrieus wind turbine that maximizes its torque at given operational conditions is proposed and presented along with the results obtained on a 7 kW prototype. The CARDAAV code, based on the “Double-Multiple Streamtube” model developed by the first author, is used to determine the performances of the straight-bladed vertical axis wind turbine. This was coupled with a genetic algorithm optimizer. The azimuthal variation of the blades' pitch angle is modeled with an analytical function whose coefficients are used as variables in the optimization process. Two types of variations were considered for the pitch angle: a simple sinusoidal one and one which is more general, relating closely the blades' pitch to the local flow conditions along their circular path. A gain of almost 30% in the annual energy production was obtained with the polynomial optimal pitch control.

  5. Optimization of the Darrieus wind turbines with double-multiple-streamtube model

    International Nuclear Information System (INIS)

    Paraschivoiu, I.

    1985-01-01

    This paper discusses a new improvement of the double-multiple-stream tube model by considering the stream tube expansion effects on the Darrieus wind turbine. These effects, allowing a more realistic modeling of the upwind/downwind flow field asymmetries inherent in the Darrieus rotor, were calculated by using CARDAAX computer code. When the dynamic stall is introduced in the double-multiple-stream tube model, the aerodynamic loads and performance show significant changes in the range of low tip-speed ratio

  6. Two laboratory methods for the calibration of GPS speed meters

    International Nuclear Information System (INIS)

    Bai, Yin; Sun, Qiao; Du, Lei; Yu, Mei; Bai, Jie

    2015-01-01

    The set-ups of two calibration systems are presented to investigate calibration methods of GPS speed meters. The GPS speed meter calibrated is a special type of high accuracy speed meter for vehicles which uses Doppler demodulation of GPS signals to calculate the measured speed of a moving target. Three experiments are performed: including simulated calibration, field-test signal replay calibration, and in-field test comparison with an optical speed meter. The experiments are conducted at specific speeds in the range of 40–180 km h −1 with the same GPS speed meter as the device under calibration. The evaluation of measurement results validates both methods for calibrating GPS speed meters. The relative deviations between the measurement results of the GPS-based high accuracy speed meter and those of the optical speed meter are analyzed, and the equivalent uncertainty of the comparison is evaluated. The comparison results justify the utilization of GPS speed meters as reference equipment if no fewer than seven satellites are available. This study contributes to the widespread use of GPS-based high accuracy speed meters as legal reference equipment in traffic speed metrology. (paper)

  7. The effect of solidity on the performance of H-rotor Darrieus turbine

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, S. M. Rakibul, E-mail: rakibulhassan21@gmail.com; Ali, Mohammad, E-mail: mali@me.buet.ac.bd; Islam, Md. Quamrul, E-mail: quamrul@me.buet.ac.bd [Department of Mechanical Engineering, Bangladesh University of Engineering and Technology, Dhaka-1000 (Bangladesh)

    2016-07-12

    Utilization of wind energy has been investigated for a long period of time by different researchers in different ways. Out of which, the Horizontal Axis Wind Turbine and the Vertical Axis Wind Turbine have now advanced design, but still there is scope to improve their efficiency. The Vertical Axis Wind Turbine (VAWT) has the advantage over Horizontal Axis Wind Turbine (HAWT) for working on omnidirectional air flow without any extra control system. A modified H-rotor Darrieus type VAWT is analysed in this paper, which is a lift based wind turbine. The effect of solidity (i.e. chord length, no. of blades) on power coefficient (C{sub P}) of H-rotor for different tip speed ratios is numerically investigated. The study is conducted using time dependent RANS equations using SST k-ω model. SIMPLE scheme is used as pressure-velocity coupling and in all cases, the second order upwind discretization scheme is chosen for getting more accurate solution. In results, different parameters are compared, which depict the performance of the modified H-rotor Darrieus type VAWT. Double layered H-rotor having inner layer blades with longer chord gives higher power coefficient than those have inner layer blades with smaller chord.

  8. Flutter of Darrieus wind turbine blades

    Science.gov (United States)

    Ham, N. D.

    1978-01-01

    The testing of Darrieus wind turbines has indicated that under certain conditions, serious vibrations of the blades can occur, involving flatwise bending, torsion, and chordwise bending. A theoretical method of predicting the aeroelastic stability of the coupled bending and torsional motion of such blades with a view to determining the cause of these vibrations, and a means of suppressing them was developed.

  9. Development and applications of new type isotope level-meters for cement factories

    International Nuclear Information System (INIS)

    Yang Shiqing; Min Hainian; Zhang Zhaoqing; Fu Heping; Dang Congjun; Wang Jingmin; Xia Junming

    1998-01-01

    According to the situation of current domestic switch isotope level-meters used for the level measurement and control in cement factories, a new type isotope level-meter is developed. The level-meter includes digit display circuit, count detection and control circuit and two ways control export, its response time is less than 1 second. The quenching circuit in the detector lengthens the using lifespan of G-M counter. The application in the factories indicates that the level-meter has the advantages of sensitive, strong anti-disturbance, reliable and adjustment simplicity. The use of the level-meter can make the better economy benefit and society benefit

  10. Scale Adaptive Simulation Model for the Darrieus Wind Turbine

    Science.gov (United States)

    Rogowski, K.; Hansen, M. O. L.; Maroński, R.; Lichota, P.

    2016-09-01

    Accurate prediction of aerodynamic loads for the Darrieus wind turbine using more or less complex aerodynamic models is still a challenge. One of the problems is the small amount of experimental data available to validate the numerical codes. The major objective of the present study is to examine the scale adaptive simulation (SAS) approach for performance analysis of a one-bladed Darrieus wind turbine working at a tip speed ratio of 5 and at a blade Reynolds number of 40 000. The three-dimensional incompressible unsteady Navier-Stokes equations are used. Numerical results of aerodynamic loads and wake velocity profiles behind the rotor are compared with experimental data taken from literature. The level of agreement between CFD and experimental results is reasonable.

  11. Turbine flow meter response in two-phase flows

    International Nuclear Information System (INIS)

    Shim, W.J.; Dougherty, T.J.; Cheh, H.Y.

    1996-01-01

    The purpose of this paper is to suggest a simple method of calibrating turbine flow meters to measure the flow rates of each phase in a two-phase flow. The response of two 50.8 mm (2 inch) turbine flow meters to air-water, two-phase mixtures flowing vertically in a 57 mm I.D. (2.25 inch) polycarbonate tube has been investigated for both upflow and downflow. The flow meters were connected in series with an intervening valve to provide an adjustable pressure difference between them. Void fractions were measured by two gamma densitometers, one upstream of the flow meters and the other downstream. The output signal of the turbine flow meters was found to depend only on the actual volumetric flow rate of the gas, F G , and liquid, F L , at the location of the flow meter

  12. Reactor Power Meter type SG-8

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W

    1981-01-01

    The report describes the principle and electronic circuits of the Reactor Power Meter type SG-8. The gamma radiation caused by the activity of the reactor first cooling circuit affectes the ionization chamber being the detector of the instrument. The output detector signal direct current is converted into the frequency of electric pulses by means of the current-to-frequency converter. The output converter frequency is measured by the digital frequency meter: the number of measured digits in time unit is proportional to the reactor power.

  13. Rotor instrumentation circuits for the Sandia 34-meter vertical axis wind turbine

    Science.gov (United States)

    Sutherland, Herbert J.; Stephenson, William A.

    1988-07-01

    Sandia National Laboratories has erected a research oriented, 34-meter diameter, Darrieus vertical axis wind turbine near Bushland, Texas, which has been designated the Sandia 34-m VAWT Test Bed. To meet present and future research needs, the machine was equipped with a large array of sensors. This manuscript details the sensors initially placed on the rotor, their respective instrumentation circuits, and the provisions incorporated into the design of the rotor instrumentation circuits for future research. This manuscript was written as a reference manual for the rotor instrumentation of the Test Bed.

  14. Two-channel neutron boron meter

    International Nuclear Information System (INIS)

    Chen Yongqing; Yin Guowei; Chai Songshan; Deng Zhaoping; Zhou Bin

    1993-09-01

    The two-channel neutron boron meter is a continuous on-line measuring device to measure boron concentration of primary cooling liquid of reactors. The neutron-leakage-compensation method is taken in the measuring mechanism. In the primary measuring configuration, the mini-boron-water annulus and two-channel and central calibration loop are adopted. The calibration ring and constant-temperature of boron-water can be remotely controlled by secondary instruments. With the microcomputer data processing system the boron concentration is automatically measured and calibrated in on-line mode. The meter has many advantages such as high accuracy, fast response, multi-applications, high reliability and convenience

  15. Experimental study of dynamic stall on Darrieus wind turbine blades

    Science.gov (United States)

    Brochier, G.; Fraunie, P.; Beguier, C.; Paraschivoiu, I.

    1985-12-01

    An experimental study of periodic vortex phenomena was performed on a model of a two straight-bladed Darrieus wind turbine under controlled-rotation conditions in the IMST water tunnel. The main focus of interest was the tip-speed ratios at which dynamic stall appears. Observations of this phenomenon from dye emission and the formation of hydrogen bubbles were made in the form of photographs, film and video recordings. Velocity measurements were obtained using the Laser-Doppler Velocimeter and components of velocity fluctuations could be determined quantitatively.

  16. An aeroelastic analysis of the Darrieus wind turbine

    Science.gov (United States)

    Meyer, E. E.; Smith, C. E.

    1983-12-01

    The stability of a single Darrieus wind turbine blade spinning in still air is investigated using linearized equations of motion. The three most dangerous flutter modes are characterized for a one-parameter family of blades. In addition, the influence of blade density, mass and aerodynamic center offsets, and structural damping is presented.

  17. Blade tip, finite aspect ratio, and dynamic stall effects on the Darrieus rotor

    Science.gov (United States)

    Paraschivoiu, I.; Desy, P.; Masson, C.

    1988-02-01

    The objective of the work described in this paper was to apply the Boeing-Vertol dynamic stall model in an asymmetric manner to account for the asymmetry of the flow between the left and right sides of the rotor. This phenomenon has been observed by the flow visualization of a two-straight-bladed Darrieus rotor in the IMST water tunnel. Also introduced into the aerodynamic model are the effects of the blade tip and finite aspect ratio on the aerodynamic performance of the Darrieus wind turbine. These improvements are compatible with the double-multiple-streamtube model and have been included in the CARDAAV computer code for predicting the aerodynamic performance. Very good agreement has been observed between the test data (Sandia 17 m) and theoretical predictions; a significant improvement over the previous dynamic stall model was obtained for the rotor power at low tip speed ratios, while the inclusion of the finite aspect ratio effects enhances the prediction of the rotor power for high tip speed ratios. The tip losses and finite aspect ratio effects were also calculated for a small-scale vertical-axis wind turbine, with a two-straight-bladed (NACA 0015) rotor.

  18. On the aerodynamics of variable-geometry oval-trajectory Darrieus wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Ponta, F.L.; Seminara, J.J.; Otero, A.D. [College of Engineering, University of Buenos Aires, Paseo Colon 850, Buenos Aires C1063ACV (Argentina)

    2007-01-15

    A new computational model for the aerodynamics of vertical-axis wind turbines is introduced. It is based on the double-multiple streamtube concept and it incorporates the capacity of dealing with rotors whose blades follow oval-trajectories at variable setting-angles. We applied this model to the study of the aerodynamics of an innovative concept in extra-large wind-power plants: the VGOT (variable-geometry oval-trajectory) Darrieus wind turbine. Due to the especial geometric characteristics of the VGOT Darrieus, it was necessary to propose three new non-dimensional parameters to quantify its performance under different wind-conditions: the equivalent power coefficient, the equivalent solidity coefficient and the trajectory efficiency. We show some numerical results testing several rotor configurations working under different wind scenarios. (author)

  19. The importance of dynamic stall in aerodynamic modeling of the Darrieus rotor

    Science.gov (United States)

    Fraunie, P.; Beguier, C.; Paraschivoiu, I.

    The CAARDEX program is defined for analyzing the behavior of Darrieus wind turbines in terms of the Reynolds number, the geometrical characteristics of the wind turbine and the spreading of the stream tubes traversing the rotor volume. It is demonstrated that the maximum power conversion efficiency of the Darrieus rotor is 0.4, with the energy capture being divided at a 4:1 ratio upstream to downstream rotor. The model shows that the velocity induced on the rotor is a function of the specific velocity and solidity, and that previous stream tube theories are valid only at low values of these parameters. CARDAAX treats the rotor disk in terms of horizontal slices of stream tubes modeled separately for the upstream and downstream segments. Account is taken of the velocity profile in the atmospheric boundary layer, which can vary significantly in the case of large wind turbines, i.e., several hundred feet high. When applied to predicting the performance of a 1 kW, 2.6 m diam prototype Darrieus wind turbine in a 10 mps flow, fair agreement is obtained for power capture/wind velocity and cyclic aerodynamic forces. Additional flow visualization data is provided to illustrate the production of turbulence in the form of vortices shed between the blades.

  20. Review Report on Design Study and Economic Assessment of Multi-Unit Offshore Wind Energy Conversion Systems Applications,

    Science.gov (United States)

    1977-03-21

    meter turbine . Available from NTIS; $6.50. 113 pages. 7. SAND-76-0130 Wind Tunnel Performance Data for the Darrieus Wind Tur- bine with NACA-0012...2-meter-diameter Darrieus wind turbine have been tested in a low speed wind tunnel. The airfoil section for all configurations was NACA 0012. The... Darrieus Vertical-Axis Wind Turbine Program at Sandia Laboratories, Kadlec, E.G., published by Sandia Laboratories 1976. Contract No. AT(29-1)-789. From

  1. Wind tunnel testing of scaled models of a newly developed Darrieus-style vertical axis wind turbine with auxiliary straight blades

    International Nuclear Information System (INIS)

    Scungio, M.; Arpino, F.; Focanti, V.; Profili, M.; Rotondi, M.

    2016-01-01

    Highlights: • Wind tunnel investigations of Darrieus-style VAWT with auxiliary blades have been made. • Results have been compared with those from standard Darrieus VAWT. • Static and dynamic power and torque coefficients were measured and evaluated. • The auxiliary airfoils have demonstrated to give more torque at the lower wind speeds. • The proposed VAWT configuration is able to work in a wide range of wind speeds. - Abstract: Renewable sources of energy, needed because of the increasing price of fossil derivatives, global warming and energy market instabilities, have led to an increasing interest in wind energy. Among the different typologies, small scale Vertical Axis Wind Turbines (VAWT) present the greatest potential for off grid power generation at low wind speeds. In the present work, wind tunnel investigations about the performance of an innovative configuration of straight-blades Darrieus-style vertical axis micro wind turbine, specifically developed for small scale energy conversion at low wind speeds, has been made on scaled models. The micro turbine under investigation consists of three pairs of airfoils. Each pair consists of a main and auxiliary airfoil with different chord lengths. A standard Darrieus configuration, consisting of three single airfoils, was also tested for comparison. The experiments were conducted in a closed circuit open chamber wind tunnel facility available at the Laboratory of Industrial Measurements (LaMI) of the University of Cassino and Lazio Meridionale (UNICLAM). Measured data were reported in terms of dimensionless power and torque coefficients for dynamic performance analysis and static torque coefficient for static performance analysis. The adoption of auxiliary airfoils has demonstrated to give more dynamic torque at the lower wind speeds with respect to a standard Darrieus rotor, resulting in better performance for all the wind speeds considered. In terms of dynamic power coefficient, the standard Darrieus

  2. Electric Circuit Model for the Aerodynamic Performance Analysis of a Three-Blade Darrieus-Type Vertical Axis Wind Turbine: The Tchakoua Model

    Directory of Open Access Journals (Sweden)

    Pierre Tchakoua

    2016-10-01

    Full Text Available The complex and unsteady aerodynamics of vertical axis wind turbines (VAWTs pose significant challenges for simulation tools. Recently, significant research efforts have focused on the development of new methods for analysing and optimising the aerodynamic performance of VAWTs. This paper presents an electric circuit model for Darrieus-type vertical axis wind turbine (DT-VAWT rotors. The novel Tchakoua model is based on the mechanical description given by the Paraschivoiu double-multiple streamtube model using a mechanical‑electrical analogy. Model simulations were conducted using MATLAB for a three-bladed rotor architecture, characterized by a NACA0012 profile, an average Reynolds number of 40,000 for the blade and a tip speed ratio of 5. The results obtained show strong agreement with findings from both aerodynamic and computational fluid dynamics (CFD models in the literature.

  3. Landau-Darrieus instability in an ablation front

    International Nuclear Information System (INIS)

    Piriz, A.R.; Portugues, R.F.

    2003-01-01

    An analytical model that shows the conditions for the existence of the Landau-Darrieus instability of an ablation front is presented. The model seems to agree with recently claimed simulation results [L. Masse et al., Proceedings of the 1st International Conference on Inertial Fusion Sciences and Applications (Elsevier, Paris, 2000), p. 220]. The model shows that the ablation front can be unstable in absence of gravity when the thermal flux is inhibited within the supercritical region of the corona

  4. Structural analysis of a 1kW Darrieus turbine spoke

    DEFF Research Database (Denmark)

    Belloni, Federico; Bedon, Gabriele; Castelli, Marco Raciti

    A structural study of a 1 kW Darrieus turbine spoke was performed in order to study stress distribution on the piece and make it more light. The VAWT turbine, originally intended for urban operation, is provided with 3 blades and 6 spokes. Since turbine initial tests showed relevant balancing...

  5. On the influence of virtual camber effect on airfoil polars for use in simulations of Darrieus wind turbines

    International Nuclear Information System (INIS)

    Rainbird, John M.; Bianchini, Alessandro; Balduzzi, Francesco; Peiró, Joaquim; Graham, J. Michael R.; Ferrara, Giovanni; Ferrari, Lorenzo

    2015-01-01

    Highlights: • Darrieus wind turbine blades are affected by virtual camber. • A NACA 0018 and two transforms of it shaped after virtual camber theory are tested. • A blockage tolerant wind tunnel test section is used for experiments. • Turbine numerical simulations for the same airfoils are compared to experiments. • Virtual camber corrections for low order simulation models are recommended. - Abstract: Darrieus vertical-axis wind turbines are experiencing renewed interest from researchers and manufacturers, though their efficiencies still lag those of horizontal-axis wind turbines. A better understanding of their aerodynamics is required to improve on designs, for example through the development of more accurate low-order (e.g. blade element momentum) models. Many of these models neglect the impact of the curved paths that are followed by blades on their performance. It has been theorized that the curved streamlines of the flow impart a virtual camber and incidence on them, giving a performance analogous to a cambered blade in a rectilinear flow. To test the extent of this effect, wind tunnel experiments have been conducted in a rectilinear flow to obtain lift and drag for three airfoils: a NACA 0018 and two conformal transforms of the profile. The transformed airfoils exhibit the virtual camber that the theory predicts is imparted to a NACA 0018 when used in a Darrieus turbine with blade chord-to-turbine radius ratios, c/R, of 0.114 and 0.25. A parallel computational fluid dynamics campaign has been conducted to study the aerodynamic behavior of the same blades in curvilinear flow in Darrieus-like motion with c/R = 0.114 and 0.25, at tip–speed ratios of 2.1 and 3.1, using novel techniques to obtain blade effective angles of attack. The analysis confirms that the theory holds, with the wind tunnel results for the NACA 0018 being analogous to numerical results for the relevant cambered airfoils. In addition, turbine performance is calculated using

  6. Double-multiple streamtube model for Darrieus in turbines

    Science.gov (United States)

    Paraschivoiu, I.

    1981-01-01

    An analytical model is proposed for calculating the rotor performance and aerodynamic blade forces for Darrieus wind turbines with curved blades. The method of analysis uses a multiple-streamtube model, divided into two parts: one modeling the upstream half-cycle of the rotor and the other, the downstream half-cycle. The upwind and downwind components of the induced velocities at each level of the rotor were obtained using the principle of two actuator disks in tandem. Variation of the induced velocities in the two parts of the rotor produces larger forces in the upstream zone and smaller forces in the downstream zone. Comparisons of the overall rotor performance with previous methods and field test data show the important improvement obtained with the present model. The calculations were made using the computer code CARDAA developed at IREQ. The double-multiple streamtube model presented has two major advantages: it requires a much shorter computer time than the three-dimensional vortex model and is more accurate than multiple-streamtube model in predicting the aerodynamic blade loads.

  7. Virtual incidence effect on rotating airfoils in Darrieus wind turbines

    International Nuclear Information System (INIS)

    Bianchini, Alessandro; Balduzzi, Francesco; Ferrara, Giovanni; Ferrari, Lorenzo

    2016-01-01

    Highlights: • Novel methods to reduce CFD results into 1D aerodynamic parameters. • Assessment of the virtual incidence (VI) effect on Darrieus VAWT blades. • It is shown that blades experience a virtual AoA variation with respect to theoretical expectations. • Real AoAs are calculated for different airfoils in motion and compared to BEM predictions. - Abstract: Small Darrieus wind turbines are one of the most interesting emerging technologies in the renewable energies scenario, even if they still are characterized by lower efficiencies than those of conventional horizontal-axis wind turbines due to the more complex aerodynamics involved in their functioning. In case of small rotors, in which the chord-to-radius ratios are generally high not to limit the blade Reynolds number, the performance of turbine blades has been suggested to be moreover influenced by the so-called “flow curvature effects”. Recent works have indeed shown that the curved flowpath encountered by the blades makes them work like virtually cambered airfoils in a rectilinear flow. In the present study, focus is instead given to a further effect that is generated in reason of the curved streamline incoming on the blades, i.e. an extra-incidence seen by the airfoil, generally referred to as “virtual incidence”. In detail, a novel computational method to define the incidence angle has been applied to unsteady CFD simulations of three airfoils in a Darrieus-like motion and their effective angles of attack have been compared to theoretical expectations. The analysis confirmed the presence of an additional virtual incidence on the airfoils and quantified it for different airfoils, chord-to-radius ratios and tip-speed ratios. A comparative discussion on BEM prediction capabilities is finally reported in the study.

  8. Two survey meters for measuring low γ-ray dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1979-01-01

    Two low-level survey meters have been developed which have numerical displays. The first is of the light-emitting diode (LED) type. The second is a liquid crystal display (LCD). The design of both instruments is described and results of measurements of performance are presented. They measure γ dose rates from background up to 2 mrad/h (20 μGy/h) for γ-rays in the energy range 0.05-1.25 MeV. They can be used at temperatures between -20 deg C and +50 deg C. Statistical accuracy and battery life both depend upon a number of factors and this dependence is shown. A later section describes the intended application of the survey meters. An appendix describes the circuit adjustments which are necessary and when they must be made. (author)

  9. Inverse airfoil design method for low-speed straight-bladed Darrieus-type VAWT applications

    Energy Technology Data Exchange (ETDEWEB)

    Saeed, F. [King Fahd Univ. of Petroleum and Minerals, Dhahran (Saudi Arabia); Paraschivoiu, I.; Trifu, O. [Ecole Polytechnique, Montreal, PQ (Canada); Hess, M.; Gabrys, C. [Mariah Power Inc., Reno, NV (United States)

    2008-07-01

    Inverse airfoil design of a low-speed straight-bladed Darrieus-type vertical axis wind turbine (VAWT) can help improve aerodynamic performance and power output by eliminating undesirable flow field characteristics at very low Reynolds number. This study used an interactive inverse airfoil design method (PROFOIL) that allows specification of velocity and boundary-layer characteristics over different segments of the airfoil subject to constraints on the geometry (closure) and the flow field (far field boundary). Additional constraints were also considered to address pitching moment coefficient, thickness and the power output for a given tip-speed ratio. Performance analyses of the airfoil and the VAWT were carried out using state-of-the-art analyses codes XFOIL and CARDAAV, respectively. XFOIL is a panel method with a coupled boundary-layer scheme and is used to obtain the aerodynamic characteristics of resulting airfoil shapes. The final airfoil geometry is obtained through a multi-dimensional Newton iteration. The study showed that the strength of the method lies in the inverse design methodology whereas its weaknesses is in reliably predicting aerodynamic characteristics of airfoils at low Reynolds numbers and high angles of attack. A 10-15 per cent increase in the relative performance of the VAWT was achieved with this method. Although the results of the study showed that the method has great application potential for VAWTs in general, there is much room for improvement in flow analysis capabilities for low Re flows in reliably predicting post-stall aerodynamic characteristics. In the absence of such analysis capabilities, the authors suggested that the results should be viewed qualitatively and not quantitatively. 36 refs., 1 tab., 4 figs.

  10. A Free Wake Numerical Simulation for Darrieus Vertical Axis Wind Turbine Performance Prediction

    Science.gov (United States)

    Belu, Radian

    2010-11-01

    In the last four decades, several aerodynamic prediction models have been formulated for the Darrieus wind turbine performances and characteristics. We can identified two families: stream-tube and vortex. The paper presents a simplified numerical techniques for simulating vertical axis wind turbine flow, based on the lifting line theory and a free vortex wake model, including dynamic stall effects for predicting the performances of a 3-D vertical axis wind turbine. A vortex model is used in which the wake is composed of trailing stream-wise and shedding span-wise vortices, whose strengths are equal to the change in the bound vortex strength as required by the Helmholz and Kelvin theorems. Performance parameters are computed by application of the Biot-Savart law along with the Kutta-Jukowski theorem and a semi-empirical stall model. We tested the developed model with an adaptation of the earlier multiple stream-tube performance prediction model for the Darrieus turbines. Predictions by using our method are shown to compare favorably with existing experimental data and the outputs of other numerical models. The method can predict accurately the local and global performances of a vertical axis wind turbine, and can be used in the design and optimization of wind turbines for built environment applications.

  11. A New Approach for Modeling Darrieus-Type Vertical Axis Wind Turbine Rotors Using Electrical Equivalent Circuit Analogy: Basis of Theoretical Formulations and Model Development

    Directory of Open Access Journals (Sweden)

    Pierre Tchakoua

    2015-09-01

    Full Text Available Models are crucial in the engineering design process because they can be used for both the optimization of design parameters and the prediction of performance. Thus, models can significantly reduce design, development and optimization costs. This paper proposes a novel equivalent electrical model for Darrieus-type vertical axis wind turbines (DTVAWTs. The proposed model was built from the mechanical description given by the Paraschivoiu double-multiple streamtube model and is based on the analogy between mechanical and electrical circuits. This work addresses the physical concepts and theoretical formulations underpinning the development of the model. After highlighting the working principle of the DTVAWT, the step-by-step development of the model is presented. For assessment purposes, simulations of aerodynamic characteristics and those of corresponding electrical components are performed and compared.

  12. A review on computational fluid dynamic simulation techniques for Darrieus vertical axis wind turbines

    International Nuclear Information System (INIS)

    Ghasemian, Masoud; Ashrafi, Z. Najafian; Sedaghat, Ahmad

    2017-01-01

    Highlights: • A review on CFD simulation technique for Darrieus wind turbines is provided. • Recommendations and guidelines toward reliable and accurate simulations are presented. • Different progresses in CFD simulation of Darrieus wind turbines are addressed. - Abstract: The global warming threats, the presence of policies on support of renewable energies, and the desire for clean smart cities are the major drives for most recent researches on developing small wind turbines in urban environments. VAWTs (vertical axis wind turbines) are most appealing for energy harvesting in the urban environment. This is attributed due to structural simplicity, wind direction independency, no yaw mechanism required, withstand high turbulence winds, cost effectiveness, easier maintenance, and lower noise emission of VAWTs. This paper reviews recent published works on CFD (computational fluid dynamic) simulations of Darrieus VAWTs. Recommendations and guidelines are presented for turbulence modeling, spatial and temporal discretization, numerical schemes and algorithms, and computational domain size. The operating and geometrical parameters such as tip speed ratio, wind speed, solidity, blade number and blade shapes are fully investigated. The purpose is to address different progresses in simulations areas such as blade profile modification and optimization, wind turbine performance augmentation using guide vanes, wind turbine wake interaction in wind farms, wind turbine aerodynamic noise reduction, dynamic stall control, self-starting characteristics, and effects of unsteady and skewed wind conditions.

  13. Numerical investigation of aerodynamic performance of darrieus wind turbine based on the magnus effect

    Directory of Open Access Journals (Sweden)

    L Khadir

    2016-10-01

    Full Text Available The use of several developmental approaches is the researchers’ major preoccupation with the DARRIEUS wind turbine. This paper presents the first approach and results of a wide computational investigation on the aerodynamics of a vertical axis DARRIEUS wind turbine based on the MAGNUS effect. Consequently, wind tunnel tests were carried out to ascertain overall performance of the turbine and two-dimensional unsteady computational fluid dynamics (CFD models were generated to help understand the aerodynamics of this new performance. Accordingly, a moving mesh technique was used where the geometry of the turbine blade was cylinders. The turbine model was created in Gambit modeling software and then read into fluent software for fluid flow analysis. Flow field characteristics are investigated for several values of tip speed ratio (TSR, in this case we generated a new rotational speed ratio between the turbine and cylinder (δ = ωC/ωT. This new concept based on the MAGNUS approach provides the best configuration for better power coefficient values. The positive results of Cp obtained in this study are used to generate energy; on the other hand, the negative values of Cp could be used in order to supply the engines with energy.

  14. Hydrogen meter prooftesting

    International Nuclear Information System (INIS)

    McCown, J.J.; Mettler, G.W.

    1976-04-01

    Two diffusion type hydrogen meters have been tested on the Prototype Applications Loop (PAL). The ANL designed unit was used to monitor hydrogen in sodium during FFTF startup and over a wide range of hydrogen concentrations resulting from chemical additions to the sodium and cover gas. A commercially available meter was added and its performance compared with the ANL unit. Details of the test work are described

  15. A progress report on an isolated Darrieus Wind Electrical System

    International Nuclear Information System (INIS)

    Katzberg, J.D.; Stewart, W.D.; Berwald, H.

    1991-01-01

    This paper discusses an isolated electrical generation system powered by a Darrieus Wind Turbine nearing completion on the farm of W. D. Stewart near Arcola (NE 5-9-4 W2). This is providing the University of Regina with a unique facility for the study of the economics and operation of isolated wind power systems, and for investigating the control and dynamics of such systems and alternatives for blade materials and coverings

  16. Advanced Metering Infrastructure based on Smart Meters

    Science.gov (United States)

    Suzuki, Hiroshi

    By specifically designating penetrations rates of advanced meters and communication technologies, devices and systems, this paper introduces that the penetration of advanced metering is important for the future development of electric power system infrastructure. It examines the state of the technology and the economical benefits of advanced metering. One result of the survey is that advanced metering currently has a penetration of about six percent of total installed electric meters in the United States. Applications to the infrastructure differ by type of organization. Being integrated with emerging communication technologies, smart meters enable several kinds of features such as, not only automatic meter reading but also distribution management control, outage management, remote switching, etc.

  17. Developments in blade shape design for a Darrieus vertical axis wind turbine

    Science.gov (United States)

    Ashwill, T. D.; Leonard, T. M.

    1986-09-01

    A new computer program package has been developed that determines the troposkein shape for a Darrieus Vertical Axis Wind Turbine Blade with any geometrical configuration or rotation rate. This package allows users to interact and develop a buildable blade whose shape closely approximates the troposkein. Use of this package can significantly reduce flatwise mean bending stresses in the blade and increase fatigue life.

  18. Output of the type 4051 and 4061 period meters during startup transients

    International Nuclear Information System (INIS)

    Cummins, J.D.

    1963-05-01

    The report describes a digital computer programme for the Ferranti Mercury computer. With this programme startup transients for the recently developed period meters Types 4051 and 4061 may be computed. The reactivity disturbances considered are steps and terminated ramps of reactivity. Due allowance is taken of the variable time constant which is a feature of these period meters. The reactor may be critical or subcritical initially as desired and the initial input time constant of the period meter may be zero or finite. Some representative transients obtained with the programme are presented and discussed. (author)

  19. Design guidelines for H-Darrieus wind turbines: Optimization of the annual energy yield

    International Nuclear Information System (INIS)

    Bianchini, Alessandro; Ferrara, Giovanni; Ferrari, Lorenzo

    2015-01-01

    Highlights: • Proposal for a new design criterion for H-Darrieus turbines based on the energy-yield maximization. • 21,600 design cases analyzed to identify the best solutions for each installation site (i.e. average wind speed). • Critical analysis of the best design choices in terms of turbine shape, dimensions, airfoils and constraints. • Notable energy increase provided by the new design approach. • Each site requires a specific turbine concept to optimize the energy yield. - Abstract: H-Darrieus wind turbines are gaining popularity in the wind energy market, particularly as they are thought to represent a suitable solution even in unconventional installation areas. To promote the diffusion of this technology, industrial manufacturers are continuously proposing new and appealing exterior solutions, coupled with tempting rated-power offers. The actual operating conditions of a rotor over a year can be, however, very different from the nominal one and strictly dependent on the features of the installation site. Based on these considerations, a turbine optimization oriented to maximize the annual energy yield, instead of the maximum power, is thought to represent a more interesting solution. With this goal in mind, 21,600 test cases of H-Darrieus rotors were compared on the basis of their energy-yield capabilities for different annual wind distributions in terms of average speed. The wind distributions were combined with the predicted performance maps of the rotors obtained with a specifically developed numerical code based on a Blade Element Momentum (BEM) approach. The influence on turbine performance of the cut-in speed was accounted for, as well as the limitations due to structural loads (i.e. maximum rotational speed and maximum wind velocity). The analysis, carried out in terms of dimensionless parameters, highlighted the aerodynamic configurations able to ensure the largest annual energy yield for each wind distribution and set of aerodynamic

  20. Aeroelastic equations of motion of a Darrieus vertical-axis wind-turbine blade

    Science.gov (United States)

    Kaza, K. R. V.; Kvaternik, R. G.

    1979-01-01

    The second-degree nonlinear aeroelastic equations of motion for a slender, flexible, nonuniform, Darrieus vertical-axis wind turbine blade which is undergoing combined flatwise bending, edgewise bending, torsion, and extension are developed using Hamilton's principle. The blade aerodynamic loading is obtained from strip theory based on a quasi-steady approximation of two-dimensional incompressible unsteady airfoil theory. The derivation of the equations has its basis in the geometric nonlinear theory of elasticity and the resulting equations are consistent with the small deformation approximation in which the elongations and shears are negligible compared to unity. These equations are suitable for studying vibrations, static and dynamic aeroelastic instabilities, and dynamic response. Several possible methods of solution of the equations, which have periodic coefficients, are discussed.

  1. Blood glucose monitoring and glycemic control in adolescents with type 1 diabetes: meter downloads versus self-report.

    Science.gov (United States)

    Guilfoyle, Shanna M; Crimmins, Nancy A; Hood, Korey K

    2011-09-01

    Reported frequencies of blood glucose monitoring (BGM) by both adolescents and their caregivers serve as adherence proxies when meter downloads are not available. Yet, correlates of reported BGM frequencies and their predictive utility are understudied. To identify sociodemographic, psychological, and disease-specific correlates of reported BGM frequencies in adolescents with type 1 diabetes and to explore the predictive utility of BGM indices on glycemic control. Study participants included caregivers and adolescents with type 1 diabetes (N=143, 13-18 yr) receiving diabetes treatment at a tertiary care setting. At the initial visit, adolescents and caregivers reported on daily BGM frequencies. A sub-sample provided meter downloads. Adolescents also completed a depression inventory. Three months later, adolescents provided blood sampling for A1c assessment. Multivariate general linear modeling identified that older adolescent age and more depressive symptoms were associated with reports of less frequent BGM. Two stepwise multivariate regression models examined the predictive utility of BGM indices (i.e., adolescent-reported BGM, caregiver-reported BGM, meter download) on glycemic control. Caregiver-reported BGM frequency predicted glycemic control in the absence of meter download data (pmeter download data were the most robust predictor of glycemic control (pMeter downloads have the most robust association with glycemic control when contextual variables are considered. Caregiver-reported BGM frequencies can serve as reliable substitutes in the absence of meter download, but they may not be as reliable in adolescents with depressive symptoms. © 2011 John Wiley & Sons A/S.

  2. A local-circulation model for Darrieus vertical-axis wind turbines

    Science.gov (United States)

    Masse, B.

    1986-04-01

    A new computational model for the aerodynamics of the vertical-axis wind turbine is presented. Based on the local-circulation method generalized for curved blades, combined with a wake model for the vertical-axis wind turbine, it differs markedly from current models based on variations in the streamtube momentum and vortex models using the lifting-line theory. A computer code has been developed to calculate the loads and performance of the Darrieus vertical-axis wind turbine. The results show good agreement with experimental data and compare well with other methods.

  3. Characteristics and calibration of the transmission-type fast neutron moisture meter

    International Nuclear Information System (INIS)

    Banzai, K.

    1984-01-01

    With the Transmission-type Fast Neutron Moisture Meter, we did some experiments for calibration and the effective range of fast neutron scattering, and observed soil moisture process before and after making artificial rainfall at a lysimeter filled by decomposed granite. A fast neutron source of this meter is 252 Cf and capacity of 100 μ Ci. The neutron detector is NE-213 liquid scintilator which recovers a little flux of neutron source. For the customary thermal neutron meter, the effective range of neutron scattering is variable by soil moisture values surrounding the observation point, but this fast neutron, insert and transmission-type meter shows soil moisture in small capacity between a source and a detector. Experimental Results; 1) The calibration curve, calculated statistically from the relation of soil moisture and the count ratio in a 200 l drum packed with beads, gravel, sand and Kanto loam, became only one line. The correlation coefficient of this curve was 0.996 and the standard error was 1.94% with volumetric water content. 2) Count ratio started to decrease as observation point approached soil surface from the boundary of 6 cm depth in soil. Volumetric water content increased more than fact with the previous calibration curve. 3) We limited the detectable range to fast neutron, but a little scattering was seen surrounding the soil of a observation point. The effective range of horizontal scattering was a width of 20 cm with the center line connected between a source and a detector, with a circle of 5 cm diameter surrounding the source, and a circle of 10-15 cm diameter surrounding the detector. 4) Soil moisture before and after artificial rainfall was observed with this meter and by the measurement of a 100 cm 3 oven dried sampling vessel. Volumetric water content by the latter measurement, was more variable because sampling points were at a distance from the center of observation site and sampling technique was bad. Otherwise soil moisture values

  4. Visualization and image analysis of dynamic stall phenomenon for a Darrieus wind turbine; Darrieus fusha ni okeru doteki shissoku gensho no kashika to gazo kaisekini kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Fujisawa, N.; Shibuya, S.; Takano, T. [Niigata University, Niigata (Japan)

    1999-10-25

    The flow field around a Darrieus wind turbine is studied by flow visualization and PIV measurement in a rotating frame of reference to understand the unsteady nature of dynamic stall appearing at low tip-speed ratios. The qualitative nature of the dynamic stall observed by the flow visualization using dye injection technique is quantitatively reproduced in the instantaneous velocity distributions around the blade measured by PIV technique. These results indicate that two pairs of stall vortices are generated in one cycle of the turbine rotation and they grow in size as the tip-speed ratio decreases. The mechanism of the dynamic stall is found to be due to the flow separation over the suction side of the blade followed by the generation of in-flow motion from the pressure side to the suction side of the blade through the trailing edge. (author)

  5. Vertical axis darrieus windmills for microinvestments in Patagonia Region of Argentina

    International Nuclear Information System (INIS)

    Labriola, C.V.M.; Chiapero, R.; Castaso, P.E.; Tabarrozzi, R.

    2000-01-01

    Wind converters used during last decades were either Horizontal Axis Converter (HAC) or Vertical Axis Converters (VAC): Darrieus, Savonius, etc. ). HAC technology, takes advantage of aerodynamic development and the progress of the last years on structural materials and electronics controls, sufficiently tested in gust wind. Thereby the manufacturers allow reaching the maximum speed that the mill can afford in the guaranteed parameter range, minimising the outs of service by gust of wind and consequently the non-supply energy periods. (Authors)

  6. Digital reactor period meter type of NSSG-7

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W

    1981-01-01

    The paper presents the idea and electronic circuits of the Digital Reactor Period Meter. The instrument consists of a neutron ionisation chamber, the amplifier logarithming the output chamber current, the circuit taking two samples of the log amplifier output signal and subtracting them, the analog -to -digital dividing circuit and the scaler providing the final information of the reactor period value in seconds and in the digital form. Besides it, the instrument produces the acoustic signal in the case, when the rise-time of neutron flux exceeds the permitted value. The untypical construction of the reactor period meter has been developed to obtain both good measurement accuracy and the resistance against the electromagnetic background pulses interfering with the measuring process. The applied measuring system has been patented.

  7. Design of h-Darrieus vertical axis wind turbine

    Science.gov (United States)

    Parra, Teresa; Vega, Carmen; Gallegos, A.; Uzarraga, N. C.; Castro, F.

    2015-05-01

    Numerical simulation is used to predict the performance of a Vertical Axis Wind Turbine (VAWT) H-Darrieus. The rotor consists of three straight blades with shape of aerofoil of the NACA family attached to a rotating vertical shaft. The influence of the solidity is tested to get design tendencies. The mesh has two fluid volumes: one sliding mesh for the rotor where the rotation velocity is established while the other is the environment of the rotor. Bearing in mind the overall flow is characterized by important secondary flows, the turbulence model selected was realizable k-epsilon with non-equilibrium wall functions. Conservation equations were solved with a Third-Order Muscl scheme using SIMPLE to couple pressure and velocity. During VAWT operation, the performance depends mainly on the relative motion of the rotating blade and has a fundamental period which depends both on the rate of rotation and the number of blades. The transient study is necessary to characterise the hysteresis phenomenon. Hence, more than six revolutions get the periodic behaviour. Instantaneous flows provide insight about wake structure interaction. Time averaged parameters let obtain the characteristic curves of power coefficient.

  8. Design of h-Darrieus vertical axis wind turbine

    Directory of Open Access Journals (Sweden)

    Parra Teresa

    2015-01-01

    Full Text Available Numerical simulation is used to predict the performance of a Vertical Axis Wind Turbine (VAWT H-Darrieus. The rotor consists of three straight blades with shape of aerofoil of the NACA family attached to a rotating vertical shaft. The influence of the solidity is tested to get design tendencies. The mesh has two fluid volumes: one sliding mesh for the rotor where the rotation velocity is established while the other is the environment of the rotor. Bearing in mind the overall flow is characterized by important secondary flows, the turbulence model selected was realizable k-epsilon with non-equilibrium wall functions. Conservation equations were solved with a Third-Order Muscl scheme using SIMPLE to couple pressure and velocity. During VAWT operation, the performance depends mainly on the relative motion of the rotating blade and has a fundamental period which depends both on the rate of rotation and the number of blades. The transient study is necessary to characterise the hysteresis phenomenon. Hence, more than six revolutions get the periodic behaviour. Instantaneous flows provide insight about wake structure interaction. Time averaged parameters let obtain the characteristic curves of power coefficient.

  9. Measurement of starting characteristics of a remote area Darrieus wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Freere, P. [Monash University, Clayton (Australia). Dept. of Electrical Engineering; Moller, C.; Jespersen, R. [Danish Technical University, Copenhagen (Denmark). Dept. of Electrical Engineering

    1999-07-01

    A 17 kW Darrieus was constructed as a remote area power supply for an independent community outside Melbourne, Australia. After languishing for several years it was reconditioned, but found not to start at wind speeds up to 12 m/s. Therefore, the turbine was modelled by driving it with an electric motor at various rotational speeds over a range of wind speeds. Thus it was possible to measure the turbine starting characteristics, thereby indicating reasons for the turbine's lack of performance. (author)

  10. CFD analysis for H-rotor Darrieus turbine as a low speed wind energy converter

    Directory of Open Access Journals (Sweden)

    M.H. Mohamed

    2015-03-01

    Full Text Available Vertical axis wind turbines like the Darrieus turbine appear to be promising for the conditions of low wind speed, but suffer from a low efficiency compared to horizontal axis turbines. A fully detailed numerical analysis is introduced in this work to improve the global performance of this wind turbine. A comparison between ANSYS Workbench and Gambit meshing tools for the numerical modeling is performed to summarize a final numerical sequence for the Darrieus rotor performance. Then, this model sequence is applied for different blade airfoils to obtain the best performance. Unsteady simulations performed for different speed ratios and based on URANS turbulent calculations using sliding mesh approach. Results show that the accuracy of ANSYS Workbench meshing is improved by using SST K-omega model but it is not recommended for other turbulence models. Moreover, this CFD procedure is used in this paper to assess the turbine performance with different airfoil shapes (25 airfoils. The results introduced new shapes for this turbine with higher efficiency than the regular airfoils by 10%. In addition, blade pitch angle has been studied and the results indicated that the zero pitch angle gives best performance.

  11. Strain gauge validation experiments for the Sandia 34-meter VAWT (Vertical Axis Wind Turbine) test bed

    Science.gov (United States)

    Sutherland, Herbert J.

    1988-08-01

    Sandia National Laboratories has erected a research oriented, 34- meter diameter, Darrieus vertical axis wind turbine near Bushland, Texas. This machine, designated the Sandia 34-m VAWT Test Bed, is equipped with a large array of strain gauges that have been placed at critical positions about the blades. This manuscript details a series of four-point bend experiments that were conducted to validate the output of the blade strain gauge circuits. The output of a particular gauge circuit is validated by comparing its output to equivalent gauge circuits (in this stress state) and to theoretical predictions. With only a few exceptions, the difference between measured and predicted strain values for a gauge circuit was found to be of the order of the estimated repeatability for the measurement system.

  12. Two-Dimensional Key Table-Based Group Key Distribution in Advanced Metering Infrastructure

    OpenAIRE

    Woong Go; Jin Kawk

    2014-01-01

    A smart grid provides two-way communication by using the information and communication technology. In order to establish two-way communication, the advanced metering infrastructure (AMI) is used in the smart grid as the core infrastructure. This infrastructure consists of smart meters, data collection units, maintenance data management systems, and so on. However, potential security problems of the AMI increase owing to the application of the public network. This is because the transmitted in...

  13. Performance Investigation of A Mix Wind Turbine Using A Clutch Mechanism At Low Wind Speed Condition

    Science.gov (United States)

    Jamanun, M. J.; Misaran, M. S.; Rahman, M.; Muzammil, W. K.

    2017-07-01

    Wind energy is one of the methods that generates energy from sustainable resources. This technology has gained prominence in this era because it produces no harmful product to the society. There is two fundamental type of wind turbine are generally used this day which is Horizontal axis wind turbine (HAWT) and Vertical axis wind turbine (VAWT). The VAWT technology is more preferable compare to HAWT because it gives better efficiency and cost effectiveness as a whole. However, VAWT is known to have distinct disadvantage compared to HAWT; self-start ability and efficiency at low wind speed condition. Different solution has been proposed to solve these issues which includes custom design blades, variable angle of attack mechanism and mix wind turbine. A new type of clutch device was successfully developed in UMS to be used in a mix Savonius-Darrieus wind turbine configuration. The clutch system which barely audible when in operation compared to a ratchet clutch system interconnects the Savonius and Darrieus rotor; allowing the turbine to self-start at low wind speed condition as opposed to a standalone Darrieus turbine. The Savonius height were varied at three different size in order to understand the effect of the Savonius rotor to the mix wind turbine performance. The experimental result shows that the fabricated Savonius rotor show that the height of the Savonius rotor affecting the RPM for the turbine. The swept area (SA), aspect ratio (AR) and tip speed ratio (TSR) also calculated in this paper. The highest RPM recorded in this study is 90 RPM for Savonius rotor 0.22-meter height at 2.75 m/s. The Savonius rotor 0.22-meter also give the highest TSR for each range of speed from 0.75 m/s, 1.75 m/s and 2.75 m/s where it gives 1.03 TSR, 0.76 TSR, and 0.55 TSR.

  14. Darrieus wind-turbine and pump performance for low-lift irrigation pumping

    Science.gov (United States)

    Hagen, L. J.; Sharif, M.

    1981-10-01

    In the Great Plains about 15 percent of the irrigation water pumped on farms comes from surface water sources; for the United States as a whole, the figure is about 22 percent. Because of forecast fuel shortages, there is a need to develop alternative energy sources such as wind power for surface water pumping. Specific objectives of this investigation were to: design and assemble a prototype wind powered pumping system for low lift irrigation pumping; determine performance of the prototype system; design and test an irrigation system using the wind powered prototype in a design and test an farm application; and determine the size combinations of wind turbines, tailwater pits, and temporary storage reservoirs needed for successful farm application of wind powered tailwater pumping systems in western Kansas. The power source selected was a two bladed, 6 m diameter, 9 m tall Darrieus vertical axis wind turbine with 0.10 solidity and 36.1 M(2) swept area.

  15. FLOW PHYSICS OF 3-BLADED STRAIGHT CHORD H-DARRIEUS WIND TURBINE

    Directory of Open Access Journals (Sweden)

    Rajat Gupta

    2013-06-01

    Full Text Available Steady-state two-dimensional Computational Fluid Dynamics (CFD simulations were performed using Fluent 6.0 software to analyze the flow physics of 3-bladed straight chord H-Darrieus wind turbine having blade twist of 300 for 10% of its chord at the trailing ends. The flow was simulated using finite volume method coupled with moving mesh technique to solve mass and momentum conservation equations. The standard k-ε turbulence model with enhanced wall condition was used. Second-order upwind discretization scheme was adopted for pressure-velocity coupling of the flow. Flow physics of the turbine was analyzed with the help of pressure and velocity contours. It was found that velocity magnitude decreases from upstream to downstream side across the turbine, which will cause overall lift for the turbine. Further, blade twist at the trailing ends creates circulations that interact with the blades in a direction opposite to the direction of rotation of the turbine which would enhance power production for the three bladed turbine.

  16. FLOW PHYSICS OF 3-BLADED STRAIGHT CHORD H- DARRIEUS WIND TURBINE

    Directory of Open Access Journals (Sweden)

    Rajat Gupta

    2013-01-01

    Full Text Available Steady-state two-dimensional Computational Fluid Dynamics (CFD simulations were performed using Fluent 6.0 software to analyze the flow physics of 3-bladed straight chord H-Darrieus wind turbine having blade twist of 300 for 10% of its chord at the trailing ends. The flow was simulated using finite volume method coupled with moving mesh technique to solve mass and momentum conservation equations. The standard k- ε turbulence model with enhanced wall condition was used. Second-order upwind discretization scheme was adopted for pressure-velocity coupling of the flow. Flow physics of the turbine was analyzed with the help of pressure and velocity contours. It was found that velocity magnitude decreases from upstream to downstream side across the turbine, which will cause overall lift for the turbine. Further, blade twist at the trailing ends creates circulations that interact with the blades in a direction opposite to the direction of rotation of the turbine which would enhance power production for the three bladed turbine.

  17. Solid state semiconductor detectorized survey meter

    International Nuclear Information System (INIS)

    Okamoto, Eisuke; Nagase, Yoshiyuki; Furuhashi, Masato

    1987-01-01

    Survey meters are used for measurement of gamma ray dose rate of the space and the surface contamination dencity that the atomic energy plant and the radiation facility etc. We have recently developed semiconductor type survey meter (Commercial name: Compact Survey Meter). This survey meter is a small-sized dose rate meter with excellent function. The special features are using semiconductor type detector which we have developed by our own technique, stablar wide range than the old type, long life, and easy to carry. Now we introduce the efficiency and the function of the survey meter. (author)

  18. Calibration of PKA meters against ion chambers of two geometries

    International Nuclear Information System (INIS)

    Almeida Junior, Jose N.; Terini, Ricardo A.; Pereira, Marco A.G.; Herdade, Silvio B.

    2011-01-01

    Kerma-area product (KAP or PKA) is a quantity that is independent of the distance to the X-ray tube focal spot and that can be used in radiological exams to assess the effective dose in patients. Clinical KAP meters are generally fixed in tube output and they are usually calibrated on-site by measuring the air kerma with an ion chamber and by evaluating the irradiated area by means of a radiographic image. Recently, a device was marketed (PDC, Patient Dose Calibrator, Radcal Co.), which was designed for calibrating clinical KAP meters with traceability to a standard laboratory. This paper presents a metrological evaluation of two methods that can be used in standard laboratories for the calibration of this device, namely, against a reference 30 cc ionization chamber or a reference parallel plates monitor chamber. Lower energy dependence was also obtained when the PDC calibration was made with the monitor chamber. Results are also shown of applying the PDC in hospital environment to the cross calibration of a clinical KAP meter from a radiology equipment. Results confirm lower energy dependence of the PDC relatively to the tested clinical meter. (author)

  19. A micro-controller based wide range survey meter

    International Nuclear Information System (INIS)

    Bhingare, R.R.; Bajaj, K.C.; Kannan, S.

    2004-01-01

    Wide range survey meters (1μSv/h -10 Sv/h) with the detector(s) mounted at the end of a two-to-four meter-long extendable tube are widely used for radiation protection survey of difficult to reach locations and high dose rate areas, The commercially available survey meters of this type use two GM counters to cover a wide range of dose rate measurement. A new micro-controller based wide range survey meter using two Si diode detectors has been developed. The use of solid state detectors in the survey meter has a number of advantages like low power consumption, lighter battery powered detector probe, elimination of high voltage for the operation of the detectors, etc. The design uses infrared communication between the probe and the readout unit through a light-weight collapsible extension tube for high reliability. The design details and features are discussed in detail. (author)

  20. On the structural behaviour of variable-geometry oval-trajectory Darrieus wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Otero, A.D. [College of Engineering, University of Buenos Aires, Paseo Colon 850, Buenos Aires C1063ACV (Argentina); Ponta, F.L. [Department of Mechanical Engineering - Engineering Mechanics, Michigan Technological University, 1400 Townsend Drive, Houghton, MI 49931 (United States)

    2009-03-15

    We developed a computational model based on a finite-element mixed formulation with quadratic isoparametric beam elements. We applied this model to the analysis of a blade-wagon: a novel structure characteristic of an innovative concept in wind-power called VGOT Darrieus turbine. We studied the structural behaviour of its main components: chassis, suspension and blade, using combinations of beam/bar elements in an appropriate assembling. We defined a set of parameters to characterize the structural behaviour which help to understand the contribution of the different components and assist the process of redesign. (author)

  1. Sodium flow measurement in large pipelines of sodium cooled fast breeder reactors with bypass type flow meters

    International Nuclear Information System (INIS)

    Rajan, K.K.; Jayakumar, T.; Aggarwal, P.K.; Vinod, V.

    2016-01-01

    Highlights: • Bypass type permanent magnet flow meters are more suitable for sodium flow measurement. • A higher sodium velocity through the PMFM sensor will increase its sensitivity and resolution. • By modifying the geometry of bypass line, higher sodium velocity through sensor is achieved. • With optimized geometry the sensitivity of bypass flow meter system was increased by 70%. - Abstract: Liquid sodium flow through the pipelines of sodium cooled fast breeder reactor circuits are measured using electromagnetic flow meters. Bypass type flow meter with a permanent magnet flow meter as sensor in the bypass line is selected for the flow measurement in the 800 NB main secondary pipe line of 500 MWe Prototype Fast Breeder Reactor (PFBR), which is at the advanced stage of construction at Kalpakkam. For increasing the sensitivity of bypass flow meters in future SFRs, alternative bypass geometry was considered. The performance enhancement of the proposed geometry was evaluated by experimental and numerical methods using scaled down models. From the studies it is observed that the new configuration increases the sensitivity of bypass flow meter system by around 70%. Using experimentally validated numerical tools the volumetric flow ratio for the bypass configurations is established for the operating range of Reynolds numbers.

  2. Two-Phase Quality/Flow Meter

    Science.gov (United States)

    Moerk, J. Steven (Inventor); Youngquist, Robert C. (Inventor); Werlink, Rudy J. (Inventor)

    1999-01-01

    A quality and/or flow meter employs a capacitance probe assembly for measuring the dielectric constant of flow stream, particularly a two-phase flow stream including liquid and gas components.ne dielectric constant of the flow stream varies depending upon the volume ratios of its liquid and gas components, and capacitance measurements can therefore be employed to calculate the quality of the flow, which is defined as the volume ratio of liquid in the flow to the total volume ratio of gas and liquid in the flow. By using two spaced capacitance sensors, and cross-correlating the time varying capacitance values of each, the velocity of the flow stream can also be determined. A microcontroller-based processing circuit is employed to measure the capacitance of the probe sensors.The circuit employs high speed timer and counter circuits to provide a high resolution measurement of the time interval required to charge each capacitor in the probe assembly. In this manner, a high resolution, noise resistant, digital representation of each of capacitance value is obtained without the need for a high resolution A/D converter, or a high frequency oscillator circuit. One embodiment of the probe assembly employs a capacitor with two ground plates which provide symmetry to insure that accurate measurements are made thereby.

  3. The development of BH3105E type neutron dose-equivalent meter

    International Nuclear Information System (INIS)

    Ji Changsong; Wang Tingting; Zhang Shuheng; Tan Baozeng

    2011-01-01

    A new BH3105E Type Neutron Dose-equivalent Meter has been developed. The 'multi-stick' ab- sorption method is used for thermal -14 MeV neutron equal dose-equivalent detection, what gives a high neutron sensitivity of 5 cps/μSv · h-1. RS-232 interface is accepted for signal communication (authors)

  4. Interference studies with two hospital-grade and two home-grade glucose meters.

    Science.gov (United States)

    Lyon, Martha E; Baskin, Leland B; Braakman, Sandy; Presti, Steven; Dubois, Jeffrey; Shirey, Terry

    2009-10-01

    Interference studies of four glucose meters (Nova Biomedical [Waltham, MA] StatStrip [hospital grade], Roche Diagnostics [Indianapolis, IN] Accu-Chek Aviva [home grade], Abbott Diabetes Care [Alameda, CA] Precision FreeStyle Freedom [home grade], and LifeScan [Milpitas, CA] SureStep Flexx [hospital grade]) were evaluated and compared to the clinical laboratory plasma hexokinase reference method (Roche Hitachi 912 chemistry analyzer). These meters were chosen to reflect the continuum of care from hospital to home grade meters commonly seen in North America. Within-run precision was determined using a freshly prepared whole blood sample spiked with concentrated glucose to give three glucose concentrations. Day-to-day precision was evaluated using aqueous control materials supplied by each vendor. Common interferences, including hematocrit, maltose, and ascorbate, were tested alone and in combination with one another on each of the four glucose testing devices at three blood glucose concentrations. Within-run precision for all glucose meters was glucose meters. Ascorbate caused differences (percentage change from a sample without added interfering substances) of >5% with pyrroloquinolinequinone (PQQ)-glucose dehydrogenase-based technologies (Aviva and Freestyle) and the glucose oxidase-based Flexx meter. Maltose strongly affected the PQQ-glucose dehydrogenase-based meter systems. When combinations of interferences (ascorbate, maltose, and hematocrit mixtures) were tested, the extent of the interference was up to 193% (Aviva), 179% (FreeStyle), 25.1% (Flexx), and 5.9% (StatStrip). The interference was most pronounced at low glucose (3.9-4.4 mmol/L). All evaluated glucose meter systems demonstrated varying degrees of interference by hematocrit, ascorbate, and maltose mixtures. PQQ-glucose dehydrogenase-based technologies showed greater susceptibility than glucose oxidase-based systems. However, the modified glucose oxidase-based amperometric method (Nova StatStrip) was

  5. Studying the effect of the shape parameters on the performance of the darrieus wind turbine using the multiple double disk stream tube theory

    International Nuclear Information System (INIS)

    Elmabrok, Ali Mohamed; Al-makhlufi, Ahmed A.

    2006-01-01

    The performance of the Darrieus vertical axis turbine is comparable with that of the more common horizontal axis machines. It has a number of aerodynamic and structural advantages over HAWTS. However the darrieus turbines are not self-starting at low wind speeds which is a considerable disadvantage for a simple small scale installation. Generally, papers concerning vertical axis turbine do not study the behavior of the rotor at low tip speed ratios. Therefore they do not deal with the self starting problems. A number of analytical methods were investigated to see whether they could predict the starting performance of vertical axis turbines. The chosen methods and 'actuator disc theory' for multiple stream tubes. In this paper the multiple stream tube model is applied using two discs in tandem. The computational analysis of all models simulates the blade aerodynamics throughout the full range of incidence from 180 degree centigrade. The effects of varying various geometric parameters of the windmill upon the performance of the rotor are investigated to find a design with improved self starting characteristics. The best agreement between theory and experiment was obtained using the multiple stream tube (double disc) models.(Author)

  6. Turbulent wind at the equatorial segment of an operating Darrieus wind turbine blade

    Science.gov (United States)

    Connell, J. R.; Morris, V. R.

    1989-09-01

    Six turbulent wind time series, measured at equally spaced equator-height locations on a circle 3 m outside a 34-m Darrieus rotor, are analyzed to approximate the wind fluctuations experienced by the rotor. The flatwise lower root-bending stress of one blade was concurrently recorded. The wind data are analyzed in three ways: wind components that are radial and tangential to the rotation of a blade were rotationally sampled; induction and wake effects of the rotor were estimated from the six Eulerian time series; and turbulence spectra of both the measured wind and the modeled wind from the PNL theory of rotationally sampled turbulence. The wind and the rotor response are related by computing the spectral response function of the flatwise lower root-bending stress. Two bands of resonant response that surround the first and second flatwise modal frequencies shift with the rotor rotation rate.

  7. Investigation and Comparison of Separate Meter-In Separate Meter-Out Control Strategies

    DEFF Research Database (Denmark)

    Pedersen, Henrik C.; Andersen, Torben Ole; Skoubo, Tobias

    2014-01-01

    In the later years, there has been an increased focus on new valve types, which yield the possibility to do Separate Meter-In Separate Meter-Out (SMISMO) control. This includes both digital valves, but proportional valves with separate metering spools and build in pressure sensors are also emerging....... The possibility to independently control the meter-in and meter-out side not only increase the functionality of the system, but also opens up for better performance and/or lowered energy consumption. The focus of the current paper is therefore on investigation and comparison of what may be obtained using...

  8. IMAGE TYPE WATER METER CHARACTER RECOGNITION BASED ON EMBEDDED DSP

    OpenAIRE

    LIU Ying; HAN Yan-bin; ZHANG Yu-lin

    2015-01-01

    In the paper, we combined DSP processor with image processing algorithm and studied the method of water meter character recognition. We collected water meter image through camera at a fixed angle, and the projection method is used to recognize those digital images. The experiment results show that the method can recognize the meter characters accurately and artificial meter reading is replaced by automatic digital recognition, which improves working efficiency.

  9. Performance assessment of Darrieus wind turbine with symmetric and cambered airfoils

    Energy Technology Data Exchange (ETDEWEB)

    Cisse, H.; Trifu, O.; Paraschivoiu, I. [Ecole Polytechnique, Montreal, PQ (Canada). Dept. de Genie Mecanique

    2007-07-01

    This paper outlined the wind turbine and design software used to predict the flow conditions and performance of a straight-bladed Darrieus wind turbine. Three different blade sections were considered, notably the NACA 0018; the SNLA NLF 18/50 symmetrical airfoil; and the FX63-137 cambered airfoil. The numerical predictions of the flow conditions during the operation of the rotors were also presented. Torque yield for each blade section under a variety of operating conditions was presented. The numerical software program used in the study was based on a double-multiple streamtube model which considered a partition of the rotor in streamtubes and considered each of the 2 blade elements as an actuator disk. The actuator disk theory was based on a theory of momentum conservation. Wind velocities were determined in order to calculate forces acting on the actuator disks. A second set of equations was used to determine the forces acting on the upwind and downwind blade elements. Equations were also derived for the downwind interference factor. The following 3 main sets of data were used: (1) a geometry definition of the wind turbine; (2) operational conditions; and (3) main control parameters. Results of the study showed that the cambered airfoil blade section produced 10 times more torque in turbine starting conditions than the NACA 0018. Laminar airfoil lift to drag ratio at low angles of attack, and the use of appropriate Reynolds numbers resulted in higher efficiency. The large static stall angle of the cambered airfoil allowed higher power outputs than symmetrical airfoils. It was concluded that the starting torque of a Darrieus turbine can be increased by using a cambered blade section. 13 refs., 19 figs.

  10. Tentative Study on Performance of Darriues-Type Hydroturbine Operated in Small Open Water Channel

    Science.gov (United States)

    Matsushita, D.; Moriyama, R.; Nakashima, K.; Watanabe, S.; Okuma, K.; Furukawa, A.

    2014-03-01

    The development of small hydropower is one of the realistic and preferable utilizations of renewable energy, but the extra-low head hydropower less than 2 m is almost undeveloped yet for some reasons. The authors have developed several types of Darrieus-type hydro-turbine system, and among them, the Darrieus-turbine with a wear and a nozzle installed upstream of turbine is so far in success to obtain more output power, i.e. more shaft torque, by gathering all water into the turbine. However, there can several cases exist, in which installing the wear covering all the flow channel width is unrealistic. Then, in the present study, the hydraulic performances of Darrieus-type hydro-turbine with the inlet nozzle is investigated, putting alone in a small open channel without upstream wear. In the experiment, the five-bladed Darrieus-type runner with the pitch-circle diameter of 300 mm and the blade span of 300 mm is vertically installed in the open channel with the width of 1,200 mm. The effectiveness of the shape of the inlet nozzle is also examined using two types of two-dimensional symmetric nozzle, the straight line nozzle (SL nozzle) with the converging angle of 45 degrees and the half diameter curved nozzle (HD nozzle) whose radius is a half diameter of runner pitch circle. Inlet and outlet nozzle widths are in common for the both nozzles, which are 540 mm and 240 mm respectively. All the experiments are carried out under the conditions with constant flow rate and downstream water level, and performances are evaluated by measured output torque and the measured head difference between the water levels upstream and downstream of the turbine. As a result, it is found that the output power is remarkably increased by installing the inlet nozzle, and the turbine with SL nozzle produces larger power than that with HD nozzle. However, the peak efficiency is deteriorated in both cases. The speed ratio defined by the rotor speed divided by the downstream water velocity at

  11. Tentative Study on Performance of Darriues-Type Hydroturbine Operated in Small Open Water Channel

    International Nuclear Information System (INIS)

    Matsushita, D; Watanabe, S; Okuma, K; Moriyama, R; Nakashima, K; Furukawa, A

    2014-01-01

    The development of small hydropower is one of the realistic and preferable utilizations of renewable energy, but the extra-low head hydropower less than 2 m is almost undeveloped yet for some reasons. The authors have developed several types of Darrieus-type hydro-turbine system, and among them, the Darrieus-turbine with a wear and a nozzle installed upstream of turbine is so far in success to obtain more output power, i.e. more shaft torque, by gathering all water into the turbine. However, there can several cases exist, in which installing the wear covering all the flow channel width is unrealistic. Then, in the present study, the hydraulic performances of Darrieus-type hydro-turbine with the inlet nozzle is investigated, putting alone in a small open channel without upstream wear. In the experiment, the five-bladed Darrieus-type runner with the pitch-circle diameter of 300 mm and the blade span of 300 mm is vertically installed in the open channel with the width of 1,200 mm. The effectiveness of the shape of the inlet nozzle is also examined using two types of two-dimensional symmetric nozzle, the straight line nozzle (SL nozzle) with the converging angle of 45 degrees and the half diameter curved nozzle (HD nozzle) whose radius is a half diameter of runner pitch circle. Inlet and outlet nozzle widths are in common for the both nozzles, which are 540 mm and 240 mm respectively. All the experiments are carried out under the conditions with constant flow rate and downstream water level, and performances are evaluated by measured output torque and the measured head difference between the water levels upstream and downstream of the turbine. As a result, it is found that the output power is remarkably increased by installing the inlet nozzle, and the turbine with SL nozzle produces larger power than that with HD nozzle. However, the peak efficiency is deteriorated in both cases. The speed ratio defined by the rotor speed divided by the downstream water velocity at

  12. (Darrieus Type

    Directory of Open Access Journals (Sweden)

    A. F. Abdel Azim El-Sayed

    1995-01-01

    consideration the dynamic stall as well as the dynamic response is developed. This method was applied to a realistic VAWT; namely; the PIONEER I built in the Netherlands by Fokker company. A reasonable agreement between the calculated and field results was predicted.

  13. Effects of the leakage magnetic field from an analog meter on the response of scintillation survey meters

    International Nuclear Information System (INIS)

    Abe, Toshiaki; Yamamoto, Hisao; Norimura, Toshiyuki; Katase, Akira

    2003-01-01

    Effects of the weak leakage magnetic field are studied on the response of two kinds of scintillation survey meters: an ordinary type for γ-rays and that optimized for the detection of low-energy photons from 125 I. In the presence of the magnetic field, the response of the optimized survey meter decreases to the photons from 125 I, and increases considerably to the background radiations. On the other hand, the response of the ordinary survey meter decreases slightly to both the γ-rays from 131 I and the background radiations. From analysis of the pulse-height spectra for the radiations, such variations of the response are ascribed to the reduction of the amplification factor of photomultiplier tubes by the magnetic field. (author)

  14. Nuclear Enterprises portable dose rate meter type PDR4 and external probes types BP1/1, BP8 and GP9

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-08-01

    The performance characteristics of Nuclear Enterprises Portable Dose Rate Meter Type PDR4 are evaluated under the headings: general description, facilities and controls, radiation characteristics, electrical characteristics, environmental characteristics, mechanical characteristics, the manual, summary of performance, and conclusions. Results of an investigation of the radiation characteristics of the external probes Type BP1/1, Type BP8, and Type GP9 are also detailed. (U.K.)

  15. Computer subroutine for estimating aerodynamic blade loads on Darrieus vertical axis wind turbines. [FORCE code

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, W. N.; Leonard, T. M.

    1980-11-01

    An important aspect of structural design of the Darrieus rotor is the determination of aerodynamic blade loads. This report describes a load generator which has been used at Sandia for quasi-static and dynamic rotor analyses. The generator is based on the single streamtube aerodynamic flow model and is constructed as a FORTRAN IV subroutine to facilitate its use in finite element structural models. Input and output characteristics of the subroutine are described and a complete listing is attached as an appendix.

  16. Study on a New Type of Electric-controlled Engine Fuel Consumption Meter Based on Volume Method

    Directory of Open Access Journals (Sweden)

    Qing-Yong Zhang

    2014-04-01

    Full Text Available At present study on the testing methods and instruments for vehicles’ fuel consumption is still not perfect. It still can’t provide a rapid and accurate measuring method and instrument. A new type of fuel consumption meter structure is developed which used two small containers to relay to supply the engine and realizes oil consumption measuring by detecting the real- time liquid level in the containers. Photoelectric sensors and a chip microcomputer are used to realize transient detection. Its structure and principle are analyzed. The system of its hardware and software of the electric-controlling system are designed. Some key components are selected and the process of exhausting, starting and measuring are designed. Precision test of the system is performed, and the result shows the accuracy of the meter in the range of 800 ml is 0.1 %, which meets the requirements and the feasibility of the structure is verified. Finally the main influencing factors are analyzed.

  17. Discussion on Music for Voices in Beijing Opera and Common Types of Meter for Music%谈京剧腔体与常用板式

    Institute of Scientific and Technical Information of China (English)

    王世萍

    2014-01-01

    京剧的唱腔是塑造人物形象的主要艺术手段,它是由不同类型的声腔和板式,结合人物性格,戏剧冲突,唱词内容和语言特点来设计的。京剧的腔体主要分西皮、二黄两大腔系,合称皮黄腔。板式颇多,一段唱腔运用什么板式或几种板式,是根据剧情发展和人物感情变化及唱词内容等设计的,是一种综合运用。%The music for voices in Beijing Opera is a major artistic means of shaping characters, and it is designed with different types of tune and meter for music, combined with personalities, opera conflicts, libretto content and language characteristics. The music for voices in Beijing Opera is mainly divided into the two types as Xipi and Erhuang, collectively referred to as Pihuang. There are a lot of types of meter for music. What type of meter or which types of meter will be used for a piece of music is designed in accordance with plot development, the character's emotional change and libretto content, which is a kind of comprehensive application.

  18. Performance prediction of asymmetrical bladed H-Darrieus VAWT rotors in low wind speed condition using CFD

    Science.gov (United States)

    Mazarbhuiya, Hussain Mahamed Sahed Mostafa; Biswas, Agnimitra; Sharma, Kaushal Kumar

    2018-04-01

    Wind energy is an essential and carbon free form of renewable energy resources. Energy can be easily extracted from wind with the use of Horizontal axis and Vertical axis wind turbine(VAWT). The performance of turbine depends on airfoil shape. The present work emphasizes the aerodynamics of different asymmetrical airfoils used in VAWT rotors. This investigation is conducted for the selection of efficient asymmetrical bladed H-Darrieus VAWT rotor. Five numbers of thick and cambered asymmetrical airfoil is considered for this investigation. A free stream velocity of 6.0 m/s is considered to simulate 2D CFD analysis using k-ɛ turbulence model. The power coefficient (Cp) of all H-Darrieus VAWT rotor increase with increase in TSR value to a certain limit and after it starts decrease with further increase of TSR. In the present investigation the Cp and TSR of NACA 63415 (RT-30%) are found to be higher among all considered asymmetrical airfoils. Moreover, Ct values of NACA 63415 (RT-30%) are also high corresponding to all TSR values. This is due to the long duration of attachment of flow with blade surroundings. Hence, NACA 63415 (RT- 30%) airfoil may be considered as an efficient airfoil among S818, GOE 561, GU25-5(11)8, and KENNEDY AND MARSDEN (kenmar) asymmetrical airfoils.

  19. Visualization and PIV measurement of unsteady flow around a darrieus wind turbine in dynamic stall

    Energy Technology Data Exchange (ETDEWEB)

    Shibuya, Satoshi; Fujisawa, Nobuyuki; Takano, Tsuyoshi [Dept. of Mechanical and Production Engineering, Niigata Univ., Niigata (Japan)

    1999-07-01

    Flow around a Darrieus wind turbine in dynamic stall is studied by flow visualization and PIV (particle image velocimeter) measurement in a rotating frame of reference, which allows the successive observation of the dynamic stall over the blade. The qualitative features of the flow field in dynamic stall observed by the flow visualization, such as the formation and shedding of the stall vortices, are quantitatively reproduced in the instantaneous velocity distributions near the blade by using PIV. These results indicate that two pairs of stall vortices are generated from the blade during one rotation of the blade and that the size and the generating blade angle of the stall vortices are enlarged as the tip-speed ratio decreases. These stall vortices are produced by the in-flow motion from the outer surface to the inner surface through the trailing edge of the blade and the flow separation over the inner surface of the blade. (author)

  20. Matching of wind turbine type and system scale to wind conditions; Chiten no fukyo ni taisuru furyoku turbine no keitai to sytem taikaku no seigosei ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Wakui, T. [Japan Society for the Promotion of Science, Tokyo (Japan); Tanzawa, Y. [Nippon Institute of Technology, Saitama (Japan); Ota, E. [Waseda University, Tokyo (Japan). School of Science and Engineering; Hashizume, T.

    2000-09-25

    The matching of the wind turbine type and system scale of the stand-alone wind turbine generator system to wind conditions is investigated using our dynamic simulation model. This paper examines three types of wind turbines: the Darrieus-Savonius hybrid wind turbine, the Darrieus turbine proper and the up-wind Propeller turbine. These systems are mainly operated at a constant tip speed ratio, which refers to a maximum power coefficient. As a computed result of the net extracting energy under fluctuations of wind speed and direction, the Darrieus turbine proper has little conformability to wind fluctuations because of its output characteristics. As for other wind turbines, large-scale systems do not always have advantages over small-scale systems as the effect of the dynamic characteristics. Furthermore, it is confirmed that the net extracting power of the Propeller turbine under wind direction fluctuations is much reduced when compared with that of the hybrid wind turbine. Thus, it is concluded that the appropriate wind turbine type and system scale exist for each wind condition. (author)

  1. Two-Dimensional Key Table-Based Group Key Distribution in Advanced Metering Infrastructure

    Directory of Open Access Journals (Sweden)

    Woong Go

    2014-01-01

    Full Text Available A smart grid provides two-way communication by using the information and communication technology. In order to establish two-way communication, the advanced metering infrastructure (AMI is used in the smart grid as the core infrastructure. This infrastructure consists of smart meters, data collection units, maintenance data management systems, and so on. However, potential security problems of the AMI increase owing to the application of the public network. This is because the transmitted information is electricity consumption data for charging. Thus, in order to establish a secure connection to transmit electricity consumption data, encryption is necessary, for which key distribution is required. Further, a group key is more efficient than a pairwise key in the hierarchical structure of the AMI. Therefore, we propose a group key distribution scheme using a two-dimensional key table through the analysis result of the sensor network group key distribution scheme. The proposed scheme has three phases: group key predistribution, selection of group key generation element, and generation of group key.

  2. Analysis of the performance of a H-Darrieus rotor under uncertainty using Polynomial Chaos Expansion

    International Nuclear Information System (INIS)

    Daróczy, László; Janiga, Gábor; Thévenin, Dominique

    2016-01-01

    Due to the growing importance of wind energy, improving the efficiency of energy conversion is essential. Horizontal Axis Wind Turbines are the most well-spread, but H-Darrieus turbines are becoming popular as well due to their simple design and easier integration. Due to the high efficiency of existing wind turbines, further improvements require numerical optimization. One important aspect is to find a better configuration that is also robust, i.e., a configuration that retains its performance under uncertainties. For this purpose, forward uncertainty propagation has to be applied. In the present work, an Uncertainty Quantification (UQ) method, Polynomial Chaos Expansion, is applied to transient, turbulent flow simulations of a variable-speed H-Darrieus turbine, taking into account uncertainty in the preset pitch angle and in the angular velocity. The resulting uncertainty of the performance coefficient and of the quasi-periodic torque curve are quantified. In the presence of stall the instantaneous torque coefficients tend to show asymmetric distributions, meaning that error bars cannot be correctly reconstructed using only mean value and standard deviation. The expected performance was always found to be smaller than in computations without UQ techniques, corresponding to up to 10% of relative losses for λ = 2.5. - Highlights: • Uncertainty Quantification/Polynomial Chaos Expansion successfully applied to H-rotor. • Accounting simultaneously for uncertainty in pitch angle and angular velocity. • Performance coefficient decreases by up to 10% when accounting for uncertainty. • For low tip-speed-ratio, high-order polynomials are needed. • Polynomial order 4 is sufficient to reconstruct distribution at higher TSR.

  3. Análisis CFD de la influencia del ángulo de Pitch en aerogeneradores H-Darrieus

    OpenAIRE

    Pérez González, Pablo

    2016-01-01

    En este Trabajo Fin de Grado se desarrolla un estudio CFD de un aerogenerador de eje vertical H-Darrieus de tres álabes con perfiles NACA 7425. El cálculo computacional se hace con el programa Fluent v.6.3.26. Partiendo de un modelo numérico en 2D, se definen las condiciones de contorno, las propiedades del fluido, los algoritmos de resolución, el modelo de turbulencia y se establece una resolución temporal. Se construyen las curvas características que definen el comportamiento del aero...

  4. Digital reactivity meter

    International Nuclear Information System (INIS)

    Jiang Zongbing

    1996-02-01

    The importance and the usual methods of reactivity measurement in a nuclear reactor are presented. Emphasis is put upon the calculation principle, software and hardware components, main specifications, application, as well as the features of the digital reactivity meter. The test results of operation in various reactors shown that the meter possess the following features: high accuracy, short response time, low output noise, high resolution, wide measuring range, simple and flexible to operate, high stability and reliability. In addition, the reactivity meter can save the measuring data automatically and have a perfect capability of self-verifying. It not only meet the requirement of the reactivity measurement in nuclear power plant, but also can be applied to various types of reactors. (1 tab.)

  5. Small power wind turbine (Type DARRIEUS

    Directory of Open Access Journals (Sweden)

    Marcel STERE

    2012-03-01

    Full Text Available This presentation focuses on the calculation for small vertical axis wind turbines (VAWT for an urban application. The fixed-pitch straight – bladed vertical axis wind turbine (SB-VAWT is one of the simplest types of wind turbine and accepts wind from any angle (no yaw system. This turbine is useful for moderate wind speeds (3 - 6 m/s. A case study is presented based upon the use of well documented symmetrical NACA 0012 turbine blade profile. We describe a solution for VAWT. To perform a linear static analysis in the structure, the commercial finite element analysis code ANSYS is used because of its flexibility for handling information in files written in a more or less free format.

  6. Calibration of ionization chamber and GM counter survey meters, (1)

    International Nuclear Information System (INIS)

    Bingo, Kazuyoshi; Kajimoto, Yoichi; Suga, Shin-ichi

    1978-01-01

    Three types of ionization chamber survey meters and a type of GM counter survey meter were calibrated for measuring the β-ray absorbed dose rate in a working area. To estimate the β-ray absorbed dose rate, a survey meter was used without and with a filter. A reading of survey meter's indicator measured with the filter was subtracted from a reading measured without the filter, and then the absorbed dose rate was obtained by multiplying this remainder by a conversion coefficient. The conversion coefficients were roughly constant with distance more than 8 cm (ionization chamber survey meters) and with distance more than 5 cm (GM counter survey meter). The conversion coefficient was dependent on β-ray energies. In order to measure the absorbed dose rate of tissue whose epidermal thickness is 40 mg/cm 2 , the constant value, 4 (mrad/h)/(mR/h), was chosen independently of β-ray energies as the conversion coefficient of three types of ionization chamber survey meters. The conversion coefficient of the GM counter survey meter was more energy dependent than that of every type of ionization chamber survey meter. (author)

  7. BH5047 type depth sand moisture-meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Xie Liangnian; Zhang Shulan; Zhang Shuheng

    2000-01-01

    A new depth neutron moisture meter BH5047 has been developed. BH5047 neutron moisture meter is characterised by it is high sensitivity and used for sand water content measurement at concrete mixer. Calibration function is obtained by the Method of Least Squares. Linear correlation efficiency is as good as 0.9977

  8. Influencia de la solidez en un aerogenerador VAWT con rotor H-Darrieus y perfiles simétricos

    OpenAIRE

    Alonso Gómez, Álvaro

    2016-01-01

    Mediante el empleo de la Mecánica Computacional de Fluidos, se estudia la influencia que tiene el grado de solidez en el comportamiento de un aerogenerador. Se estudia un aerogenerador de eje vertical con rotor H-Darrieus y tres perfiles simétricos en el que se analizan tres grados de solidez diferentes, generándose por lo tanto tres modelos, para cada uno de los cuales se obtiene la curva de rendimiento correspondiente. Para construir la curva se van realizando simulaciones a diferentes ve...

  9. Integration of auditory and tactile inputs in musical meter perception.

    Science.gov (United States)

    Huang, Juan; Gamble, Darik; Sarnlertsophon, Kristine; Wang, Xiaoqin; Hsiao, Steven

    2013-01-01

    Musicians often say that they not only hear but also "feel" music. To explore the contribution of tactile information to "feeling" music, we investigated the degree that auditory and tactile inputs are integrated in humans performing a musical meter-recognition task. Subjects discriminated between two types of sequences, "duple" (march-like rhythms) and "triple" (waltz-like rhythms), presented in three conditions: (1) unimodal inputs (auditory or tactile alone); (2) various combinations of bimodal inputs, where sequences were distributed between the auditory and tactile channels such that a single channel did not produce coherent meter percepts; and (3) bimodal inputs where the two channels contained congruent or incongruent meter cues. We first show that meter is perceived similarly well (70-85 %) when tactile or auditory cues are presented alone. We next show in the bimodal experiments that auditory and tactile cues are integrated to produce coherent meter percepts. Performance is high (70-90 %) when all of the metrically important notes are assigned to one channel and is reduced to 60 % when half of these notes are assigned to one channel. When the important notes are presented simultaneously to both channels, congruent cues enhance meter recognition (90 %). Performance dropped dramatically when subjects were presented with incongruent auditory cues (10 %), as opposed to incongruent tactile cues (60 %), demonstrating that auditory input dominates meter perception. These observations support the notion that meter perception is a cross-modal percept with tactile inputs underlying the perception of "feeling" music.

  10. Vertical axis wind turbines: a survey and bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Abramovich, H

    1987-01-01

    The stimulus for the development of modern, big wind turbines has been the world-wide oil crisis during the seventies. Although the horizontal axis wind turbines (HAWT) was the most popular type of wind turbine the Darrieus vertical axis wind turbine (VAWT) has been recognized as a machine with competitive economic potential. The state of the art of the VAWT is reviewed. The wind turbine carrying the name of Darrieus was first proposed by the French inventor in 1925. His original patent covered a range of vertical-axis configurations but the term 'Darrieus' is now generally associated with the curved-blade geometry. In 1966 two researchers at the Canadian NRC again raised the idea of both the straight and curved-blade versions of the Darrieus VAWT.

  11. Isotope-equipped electrostatic field meter, type RMEL-70, manufactured by the ''Polon'' Works, Cracow

    Energy Technology Data Exchange (ETDEWEB)

    Szumska, B; Tomaszewski, W

    1973-01-01

    The authors describe the operating principle, design features and use of an isotope-equipped meter, type RMEL-70, for measuring electrostatic field intensity and surface charge density. Being a light, portable instrument, it permits to determine the degree of electrification of dielectrics, evaluate the hazard of charge being collected, and to check the effectiveness of deionizers installed in industrial plants.

  12. Computational investigation of flow control by means of tubercles on Darrieus wind turbine blades

    Science.gov (United States)

    Sevinç, K.; Özdamar, G.; Şentürk, U.; Özdamar, A.

    2015-09-01

    This work presents the current status of the computational study of the boundary layer control of a vertical axis wind turbine blade by modifying the blade geometry for use in wind energy conversion. The control method is a passive method which comprises the implementation of the tubercle geometry of a humpback whale flipper onto the leading edge of the blades. The baseline design is an H-type, three-bladed Darrieus turbine with a NACA 0015 cross-section. Finite-volume based software ANSYS Fluent was used in the simulations. Using the optimum control parameters for a NACA 634-021 profile given by Johari et al. (2006), turbine blades were modified. Three dimensional, unsteady, turbulent simulations for the blade were conducted to look for a possible improvement on the performance. The flow structure on the blades was investigated and flow phenomena such as separation and stall were examined to understand their impact on the overall performance. For a tip speed ratio of 2.12, good agreement was obtained in the validation of the baseline model with a relative error in time- averaged power coefficient of 1.05%. Modified turbine simulations with a less expensive but less accurate turbulence model yielded a decrease in power coefficient. Results are shown comparatively.

  13. The measuring system and practical uses of the universal radiation meter type TSM-11

    International Nuclear Information System (INIS)

    Rozsa, S.; Szabo, Gy.; Szem, I.; Vereczky, L.

    1980-01-01

    The industrial radiation meter in its signal conversion follows the ratemeter principle and uses pulse detectors. By its built-in zero suppression and scale extension the device makes the display of two pulses differing from each other at least by 10% and their conversion onto the output signal range of 0-20 mA possible. The information from the different measuring sections developed for industrial purposes are processed by the same device. The operation principles of and the experience gathered with the radiometer in its use in industry as density, level, thickness gauge, moisture and quantity meter and belt scales are discussed. (author)

  14. Effect of Doppler flow meter position on discharge measurement in surcharged manholes.

    Science.gov (United States)

    Yang, Haoming; Zhu, David Z; Liu, Yanchen

    2018-02-01

    Determining the proper installation location of flow meters is important for accurate measurement of discharge in sewer systems. In this study, flow field and flow regimes in two types of manholes under surcharged flow were investigated using a commercial computational fluid dynamics (CFD) code. The error in measuring the flow discharge using a Doppler flow meter (based on the velocity in a Doppler beam) was then estimated. The values of the corrective coefficient were obtained for the Doppler flow meter at different locations under various conditions. Suggestions for selecting installation positions are provided.

  15. A two meter long straw tube prototype for the FINUDA experiment

    International Nuclear Information System (INIS)

    Benussi, L.; Bertani, M.; Bianco, S.; Fabbri, F.L.; Gianotti, P.; Giardoni, M.; Guaraldo, C.; Lanaro, A.; Lucherini, V.; Mecozzi, A.; Passamonti, L.; Russo, V.; Sarwar, S.

    1995-01-01

    A prototype using several 10mm and 20mm diameter, two meter long aluminized mylar straws has been assembled and tested with a one GeV/c pion beam. While operating with dimethyl ether space resolution, and device systematics have been studied. A simple method for measuring straw eccentricity and correcting for the corresponding systematics has been developed and, once applied, a space resolution better than 40μm can be reached. (orig.)

  16. Modelling and calibration of a ring-shaped electrostatic meter

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Jianyong [University of Teesside, Middlesbrough TS1 3BA (United Kingdom); Zhou Bin; Xu Chuanlong; Wang Shimin, E-mail: zhoubinde1980@gmail.co [Southeast University, Sipailou 2, Nanjing 210096 (China)

    2009-02-01

    Ring-shaped electrostatic flow meters can provide very useful information on pneumatically transported air-solids mixture. This type of meters are popular in measuring and controlling the pulverized coal flow distribution among conveyors leading to burners in coal-fired power stations, and they have also been used for research purposes, e.g. for the investigation of electrification mechanism of air-solids two-phase flow. In this paper, finite element method (FEM) is employed to analyze the characteristics of ring-shaped electrostatic meters, and a mathematic model has been developed to express the relationship between the meter's voltage output and the motion of charged particles in the sensing volume. The theoretical analysis and the test results using a belt rig demonstrate that the output of the meter depends upon many parameters including the characteristics of conditioning circuitry, the particle velocity vector, the amount and the rate of change of the charge carried by particles, the locations of particles and etc. This paper also introduces a method to optimize the theoretical model via calibration.

  17. Comparison of NACA 6-series and 4-digit airfoils for Darrieus wind turbines

    Science.gov (United States)

    Migliore, P. G.

    1983-08-01

    The aerodynamic efficiency of Darrieus wind turbines as effected by blade airfoil geometry was investigated. Analysis was limited to curved-bladed machines having rotor solidities of 7-21 percent and operating at a Reynolds number of 3 x 10 to the 6th. Ten different airfoils, having thickness-to-chord ratios of 12, 15, and 18 percent, were studied. Performance estimates were made using a blade element/momentum theory approach. Results indicated that NACA 6-series airfoils yield peak power coefficients as great as NACA 4-digit airfoils and have broader and flatter power coefficient-tip speed ratio curves. Sample calculations for an NACA 63(2)-015 airfoil showed an annual energy output increase of 17-27 percent, depending on rotor solidity, compared to an NACA 0015 airfoil.

  18. Limitations of fixed pitch Darrieus hydrokinetic turbines and the challenge of variable pitch

    Energy Technology Data Exchange (ETDEWEB)

    Kirke, B.K. [Sustainable Energy Centre, University of South Australia, Mawson Lakes, SA 5095 (Australia); Lazauskas, L. [Cyberiad, 25/65 King William Street, Adelaide, SA 5000 (Australia)

    2011-03-15

    Small Darrieus hydrokinetic turbines with fixed pitch blades typically suffer from poor starting torque, low efficiency and shaking due to large fluctuations in both radial and tangential force with azimuth angle. Efficiency improves as size increases, since adequate blade chord Reynolds numbers can be maintained with low solidity. Shaking can be eliminated by using helical blades, or reduced by using multiple blades. Starting torque can be marginally improved by the use of cambered blade profiles but may still be inadequate to overcome drive train friction for self-starting. Variable pitch can generate high starting torque, high efficiency and reduced shaking but active pitch control systems add considerably to complexity and cost, while passive systems must have effective pitch control to achieve higher efficiency than fixed pitch systems. (author)

  19. Feedback control of a Darrieus wind turbine and optimization of the produced energy

    Science.gov (United States)

    Maurin, T.; Henry, B.; Devos, F.; de Saint Louvent, B.; Gosselin, J.

    1984-03-01

    A microprocessor-driven control system, applied to the feedback control of a Darrieus wind turbine is presented. The use of a dc machine as a generator to recover the energy and as a motor to start the engine, allows simplified power electronics. The architecture of the control unit is built to ensure four different functions: starting, optimization of the recoverable energy, regulation of the speed, and braking. An experimental study of the system in a wind tunnel allowed optimization of the coefficients of the proportional and integral (pi) control algorithm. The electrical energy recovery was found to be much more efficient using the feedback system than without the control unit. This system allows a better characterization of the wind turbine and a regulation adapted to the wind statistics observed in one given geographical location.

  20. Investigation of the mixture flow rates of oil-water two-phase flow using the turbine flow meter

    International Nuclear Information System (INIS)

    Li Donghui; Feng Feifei; Wu Yingxiang; Xu Jingyu

    2009-01-01

    In this work, the mixture flow rate of oil-water flows was studied using the turbine flow-meter. The research emphasis focuses on the effect of oil viscosity and input fluids flow rates on the precision of the meter. Experiments were conducted to measure the in-situ mixture flow rate in a horizontal pipe with 0.05m diameter using seven different viscosities of white oil and tap water as liquid phases. Results showed that both oil viscosity and input oil fraction exert a remarkable effect on measured results, especially when the viscosity of oil phase remained in the area of high value. In addition, for metering mixture flow rate using turbine flow-meter, the results are not sensitive to two-phase flow pattern according to the experimental data.

  1. Effect of gas temperature on flow rate characteristics of an averaging pitot tube type flow meter

    Energy Technology Data Exchange (ETDEWEB)

    Yeo, Seung Hwa; Lee, Su Ryong; Lee, Choong Hoon [Seoul National University of Science and Technology, Seoul (Korea, Republic of)

    2015-01-15

    The flow rate characteristics passing through an averaging Pitot tube (APT) while constantly controlling the flow temperature were studied through experiments and CFD simulations. At controlled temperatures of 25, 50, 75, and 100 .deg .C, the flow characteristics, in this case the upstream, downstream and static pressure at the APT flow meter probe, were measured as the flow rate was increased. The flow rate through the APT flow meter was represented using the H-parameter (hydraulic height) obtained by a combination of the differential pressure and the air density measured at the APT flow meter probe. Four types of H-parameters were defined depending on the specific combination. The flow rate and the upstream, downstream and static pressures measured at the APT flow meter while changing the H-parameters were simulated by means of CFD. The flow rate curves showed different features depending on which type of H-parameter was used. When using the constant air density value in a standard state to calculate the H-parameters, the flow rate increased linearly with the H-parameter and the slope of the flow rate curve according to the H-parameter increased as the controlled target air temperature was increased. When using different air density levels corresponding to each target air temperature to calculate the H-parameter, the slope of the flow rate curve according to the H-parameter was constant and the flow rate curve could be represented by a single line. The CFD simulation results were in good agreement with the experimental results. The CFD simulations were performed while increasing the air temperature to 1200 K. The CFD simulation results for high air temperatures were similar to those at the low temperature ranging from 25 to 100 .deg. C.

  2. Effect of gas temperature on flow rate characteristics of an averaging pitot tube type flow meter

    International Nuclear Information System (INIS)

    Yeo, Seung Hwa; Lee, Su Ryong; Lee, Choong Hoon

    2015-01-01

    The flow rate characteristics passing through an averaging Pitot tube (APT) while constantly controlling the flow temperature were studied through experiments and CFD simulations. At controlled temperatures of 25, 50, 75, and 100 .deg .C, the flow characteristics, in this case the upstream, downstream and static pressure at the APT flow meter probe, were measured as the flow rate was increased. The flow rate through the APT flow meter was represented using the H-parameter (hydraulic height) obtained by a combination of the differential pressure and the air density measured at the APT flow meter probe. Four types of H-parameters were defined depending on the specific combination. The flow rate and the upstream, downstream and static pressures measured at the APT flow meter while changing the H-parameters were simulated by means of CFD. The flow rate curves showed different features depending on which type of H-parameter was used. When using the constant air density value in a standard state to calculate the H-parameters, the flow rate increased linearly with the H-parameter and the slope of the flow rate curve according to the H-parameter increased as the controlled target air temperature was increased. When using different air density levels corresponding to each target air temperature to calculate the H-parameter, the slope of the flow rate curve according to the H-parameter was constant and the flow rate curve could be represented by a single line. The CFD simulation results were in good agreement with the experimental results. The CFD simulations were performed while increasing the air temperature to 1200 K. The CFD simulation results for high air temperatures were similar to those at the low temperature ranging from 25 to 100 .deg. C.

  3. BH3105 type neutron dose equivalent meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Enshan; Yang Jianfeng; Zhang Hong; Huang Jiling

    1995-10-01

    It is noted that to design a neutron dose meter of high sensitivity is almost impossible in the frame of traditional designing principle--'absorption net principle'. Based on a newly proposed principle of obtaining neutron dose equi-biological effect adjustment--' absorption stick principle', a brand-new neutron dose-equivalent meter with high neutron sensitivity BH3105 has been developed. Its sensitivity reaches 10 cps/(μSv·h -1 ), which is 18∼40 times higher than one of foreign products of the same kind and is 10 4 times higher than that of domestic FJ342 neutron rem-meter. BH3105 has a measurement range from 0.1μSv/h to 1 Sv/h which is 1 or 2 orders wider than that of the other's. It has the advanced properties of gamma-resistance, energy response, orientation, etc. (6 tabs., 5 figs.)

  4. Evaluating the student activity meter : two case studies

    NARCIS (Netherlands)

    Govaerts, S.; Verbert, K.; Duval, E.

    2011-01-01

    In the Technology Enhanced Learning (TEL) domain, visualizations are attracting increased interest. In this paper, we present the Student Activity Meter that visualizes learner activities within online learning environments for learners and teachers to help increase awareness and to support

  5. Measuring set: Reactor Power Meter (type of SG-8), Reactor Energy Meter (type of SG-11) and Digital Dose Meter (type of SG-9) for reactor rigs operation. Zestaw pomiarowy: miernik mocy reaktora (typ SG-8), miernik energii reaktora (typ SG-11) oraz cyfrowy miernik dawki (typ SG-9) dla potrzeb eksploatacji sond reaktorowych

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W

    1982-01-01

    A measuring set consisting of the Reactor Power Meter, Reactor Energy Meter and Digital Dose Meter is described. The gamma radiation of water in the reactor primary cooling circuit reaches the ionisation chamber and involves the output current, driving the Reactor Power Meter and Reactor Energy Meter. The Digital Dose Meter is controlled by the output current of the self-powered detector mounted inside the reactor rig.

  6. Impedance void-meter and neural networks for vertical two-phase flows

    International Nuclear Information System (INIS)

    Mi, Y.; Li, M.; Xiao, Z.; Tsoukalas, L.H.; Ishii, M.

    1998-01-01

    Most two-phase flow measurements, including void fraction measurements, depend on correct flow regime identification. There are two steps towards successful identification of flow regimes: one is to develop a non-intrusive instrument to demonstrate area-averaged void fluctuations, the other to develop a non-linear mapping approach to perform objective identification of flow regimes. A non-intrusive impedance void-meter provides input signals to a neural mapping approach used to identify flow regimes. After training, both supervised and self-organizing neural network learning paradigms performed flow regime identification successfully. The methodology presented holds considerable promise for multiphase flow diagnostic and measurement applications. (author)

  7. Feeling music: integration of auditory and tactile inputs in musical meter perception.

    Science.gov (United States)

    Huang, Juan; Gamble, Darik; Sarnlertsophon, Kristine; Wang, Xiaoqin; Hsiao, Steven

    2012-01-01

    Musicians often say that they not only hear, but also "feel" music. To explore the contribution of tactile information in "feeling" musical rhythm, we investigated the degree that auditory and tactile inputs are integrated in humans performing a musical meter recognition task. Subjects discriminated between two types of sequences, 'duple' (march-like rhythms) and 'triple' (waltz-like rhythms) presented in three conditions: 1) Unimodal inputs (auditory or tactile alone), 2) Various combinations of bimodal inputs, where sequences were distributed between the auditory and tactile channels such that a single channel did not produce coherent meter percepts, and 3) Simultaneously presented bimodal inputs where the two channels contained congruent or incongruent meter cues. We first show that meter is perceived similarly well (70%-85%) when tactile or auditory cues are presented alone. We next show in the bimodal experiments that auditory and tactile cues are integrated to produce coherent meter percepts. Performance is high (70%-90%) when all of the metrically important notes are assigned to one channel and is reduced to 60% when half of these notes are assigned to one channel. When the important notes are presented simultaneously to both channels, congruent cues enhance meter recognition (90%). Performance drops dramatically when subjects were presented with incongruent auditory cues (10%), as opposed to incongruent tactile cues (60%), demonstrating that auditory input dominates meter perception. We believe that these results are the first demonstration of cross-modal sensory grouping between any two senses.

  8. Cancer-meter: measure and cure.

    Science.gov (United States)

    Kashyap, Sunil Kumar; Sharma, Birendra Kumar; Banerjee, Amitabh

    2017-05-01

    This paper presents a theory and system on "Cancer-Meter'. This idea came through the statement that "cancer is curable if it is measurable". The Cancer-Meter proves that it is possible. This paper proposes the cancer-meter in two ways, theoretical and electronically, as per the measurement and treatment. By the mathematics, first part is defined but the second part is based on computer programming, electrical and electronics. Thus, the cancer-meter is a programmed-electrical-electronic device which measures and cures the cancer both.

  9. Highly accurate Michelson type wavelength meter that uses a rubidium stabilized 1560 nm diode laser as a wavelength reference

    International Nuclear Information System (INIS)

    Masuda, Shin; Kanoh, Eiji; Irisawa, Akiyoshi; Niki, Shoji

    2009-01-01

    We investigated the accuracy limitation of a wavelength meter installed in a vacuum chamber to enable us to develop a highly accurate meter based on a Michelson interferometer in 1550 nm optical communication bands. We found that an error of parts per million order could not be avoided using famous wavelength compensation equations. Chromatic dispersion of the refractive index in air can almost be disregarded when a 1560 nm wavelength produced by a rubidium (Rb) stabilized distributed feedback (DFB) diode laser is used as a reference wavelength. We describe a novel dual-wavelength self-calibration scheme that maintains high accuracy of the wavelength meter. The method uses the fundamental and second-harmonic wavelengths of an Rb-stabilized DFB diode laser. Consequently, a highly accurate Michelson type wavelength meter with an absolute accuracy of 5x10 -8 (10 MHz, 0.08 pm) over a wide wavelength range including optical communication bands was achieved without the need for a vacuum chamber.

  10. A review of net metering mechanism for electricity renewable energy sources

    Energy Technology Data Exchange (ETDEWEB)

    Poullikkas, Andreas; Kourtis, George; Hadjipaschalis, Ioannis [Electricity Authority of Cyprus, P.O. Box 24506, 1399 Nicosia (Cyprus)

    2013-07-01

    In this work, an overview of the net metering mechanism for renewable energy sources for power generation (RES-E) systems is carried out. In particular, the net metering concept is examined with its benefits and misconceptions. Furthermore, a survey of the current operational net metering schemes in different countries in the world, such as, in Europe, USA, Canada, Thailand and Australia, is carried out. The survey indicated that there are different net metering mechanisms depending on the particularities of each country (or state in the case of USA). Especially, in Europe, only five countries are using net metering in a very simple form, such as, any amount of energy produced by the eligible RES-E technology is compensated from the energy consumed by the RES-E producer, which results to either a less overall electricity bill or to an exception in payment energy taxes. In the USA and the USA territories, any customer’s net excess generation is credited to the customer’s next electricity bill for a 12-month billing cycle at various rates or via a combination between rates. The actual type of net excess generation (NEG) credit is decided by a number of set criteria, such as the type of RES-E technology, the RES-E capacity limit, the type of customer and the type of utility. Regarding any excess credit at the end of the 12-month billing cycle, this is either granted to the utilities, or carries over indefinitely to the customer’s next electricity bill, or is reconciled annually at any rate, or provides an option to the customer to choose between the last two options.

  11. Calibration of reference KAP-meters at SSDL and cross calibration of clinical KAP-meters

    International Nuclear Information System (INIS)

    Hetland, Per O.; Friberg, Eva G.; Oevreboe, Kirsti M.; Bjerke, Hans H.

    2009-01-01

    In the summer of 2007 the secondary standard dosimetry laboratory (SSDL) in Norway established a calibration service for reference air-kerma product meter (KAP-meter). The air-kerma area product, PKA, is a dosimetric quantity that can be directly related to the patient dose and used for risk assessment associated with different x-ray examinations. The calibration of reference KAP-meters at the SSDL gives important information on parameters influencing the calibration factor for different types of KAP-meters. The use of reference KAP-meters calibrated at the SSDL is an easy and reliable way to calibrate or verify the PKA indicated by the x-ray equipment out in the clinics. Material and methods. Twelve KAP-meters were calibrated at the SSDL by use of the substitution method at five diagnostic radiation qualities (RQRs). Results. The calibration factors varied from 0.94 to 1.18. The energy response of the individual KAP-meters varied by a total of 20% between the different RQRs and the typical chamber transmission factors ranged from 0.78 to 0.91. Discussion. It is important to use a calibrated reference KAP-meter and a harmonised calibration method in the PKA calibration in hospitals. The obtained uncertainty in the PKA readings is comparable with other calibration methods if the information in the calibration certificate is correct used, corrections are made and proper positioning of the KAP-chamber is performed. This will ensure a reliable estimate of the patient dose and a proper optimisation of conventional x-ray examinations and interventional procedures

  12. Pulse counting period meter output during startup transients

    International Nuclear Information System (INIS)

    Cummins, J.D.

    1962-12-01

    The time response of a period meter whose input signal comes from a pulse counting channel may be calculated using a Ferranti Mercury autocode programme details of which are given. The period meter considered is the type for which the logarithmic characteristic is approximated by several diode pump circuits. The input excitation is a terminated ramp of reactivity. Other reactivity inputs may be treated. In particular the step change of reactivity may be used as the input excitation. Allowance is made for the effective time constants of the diode pump circuits and the period meter. The programme may be used for instrument assessment and for safety and operations studies on reactors which use this type of period meter. An example of the use of the programme is given. (author)

  13. Neural processing of musical meter in musicians and non-musicians.

    Science.gov (United States)

    Zhao, T Christina; Lam, H T Gloria; Sohi, Harkirat; Kuhl, Patricia K

    2017-11-01

    Musical sounds, along with speech, are the most prominent sounds in our daily lives. They are highly dynamic, yet well structured in the temporal domain in a hierarchical manner. The temporal structures enhance the predictability of musical sounds. Western music provides an excellent example: while time intervals between musical notes are highly variable, underlying beats can be realized. The beat-level temporal structure provides a sense of regular pulses. Beats can be further organized into units, giving the percept of alternating strong and weak beats (i.e. metrical structure or meter). Examining neural processing at the meter level offers a unique opportunity to understand how the human brain extracts temporal patterns, predicts future stimuli and optimizes neural resources for processing. The present study addresses two important questions regarding meter processing, using the mismatch negativity (MMN) obtained with electroencephalography (EEG): 1) how tempo (fast vs. slow) and type of metrical structure (duple: two beats per unit vs. triple: three beats per unit) affect the neural processing of metrical structure in non-musically trained individuals, and 2) how early music training modulates the neural processing of metrical structure. Metrical structures were established by patterns of consecutive strong and weak tones (Standard) with occasional violations that disrupted and reset the structure (Deviant). Twenty non-musicians listened passively to these tones while their neural activities were recorded. MMN indexed the neural sensitivity to the meter violations. Results suggested that MMNs were larger for fast tempo and for triple meter conditions. Further, 20 musically trained individuals were tested using the same methods and the results were compared to the non-musicians. While tempo and meter type similarly influenced MMNs in both groups, musicians overall exhibited significantly reduced MMNs, compared to their non-musician counterparts. Further analyses

  14. Investigation of the structural behavior of the blades of a darrieus wind turbine†

    Science.gov (United States)

    Rosen, A.; Abramovich, H.

    1985-06-01

    A theoretical model in which account is taken of the non-linear, non-planar structural behavior of the curved blades of a Darrieus wind turbine is described. This model is simpler and needs less computational effort than some other models, but is still accurate enough for most engineering purposes. By using the present method, it is possible to treat any blade geometry, any structural, mass and aerodynamic blade properties distribution and any combination of boundary conditions. The model is used in order to calculate the blade behavior under the influence of concentrated loads, gravity loads and centrifugal loads. In order to verify the theoretical model, predictions are compared with experimental results which are obtained from tests with small models of curved blades. Usually the agreement between the theoretical and experimental results is very good. The influence of different parameters on blade behavior is presented and discussed.

  15. Metering Plan: Intelligent Operational Strategies Through Enhanced Metering Systems

    Energy Technology Data Exchange (ETDEWEB)

    Pope, Jason E.

    2016-07-27

    The Sustainability Program at Pacific Northwest National Laboratory (PNNL) has adopted a “triple-bottom-line” approach of environmental stewardship, social responsibility, and economic prosperity to its operations. Metering at PNNL works in support of all three, specifically to measure and inform building energy use and greenhouse gas emissions and minimize water use. The foundation for metering at PNNL is a core goal set, which consists of four objectives: providing accurate data without interruption, analyzing data while it is still new, providing actionable recommendations to operations management, and ensuring PNNL’s compliance with contract metering requirements. These core objectives guide the decisions that we make during annual planning and as we operate throughout the year. This 2016 edition of the Metering Plan conveys the metering practices for and vision of the Sustainability Program. Changes in this plan from the 2015 edition include updated tables and an enhanced discussion on energy tracking systems used at PNNL. This plan also discusses updated benchmarking strategies using PNNL’s graphics and analytics tool, BuildingOS by Lucid Design Group. This plan presents our progress toward the metering goals shared by all federal agencies and highlights our successful completion of metering requirements. Currently, PNNL is fully compliant with the applicable legislative and Executive Order metering requirements. PNNL’s approach to the installation of new meters will be discussed. Perhaps most importantly, this plan details the analysis techniques utilized at PNNL that rely on the endless streams of data newly available as a result of increased meter deployment over the last several years. Previous Metering Plans have documented specific meter connection schemes as PNNL focused on deploying meters in a first step toward managing energy and water use. This plan serves not only to highlight PNNL’s successful completion of agency metering goals, but

  16. Investigation of Separate Meter-In Separate Meter-Out Control Strategies for Systems with Over Centre Valves

    DEFF Research Database (Denmark)

    Pedersen, Henrik C.; Andersen, Torben Ole; Hansen, Rico Hjerm

    2010-01-01

    to overcome this problem, but it typically implies higher energy consumption and/or decreased control performance. With the development of robust sensors and new valve types with separate meter-in, separate meter-out control it is, however, possible to overcome these stability problems in a much more...... intelligent way, also adding increased functionality to the system. The focus of the current paper is therefore on investigation of different control strategies for Separate Meter-In Separate Meter-Out (SMISMO) control of general single axis hydraulic system with a differential cylinder and an over......-centre valve included. The paper first presents a general model of the system considered, which is experimentally verified. This is followed by a discussion of different control strategies and their implications. For each of the control strategies controllers are described, taking into account the dynamics...

  17. Properties of cellulose triacetate dose meter

    International Nuclear Information System (INIS)

    Tamura, N.; Tanaka, R.; Mitomo, S.; Matsuda, K.; Nagai, S.

    1981-01-01

    Several clear plastics and dyed plastics are commercially available for dosimetry in intense radiation field, especially for radiation processing applications. Among these dose meters cellulose triacetate (CTA) dose meter has two advantages for routine uses; (1) it has linear response in mega-rad dose region and (2) the main product form is long tape. However, the manufacture of Numelec CTA film so far used had been discontinued, and for this reason we developed a new film for dosimetry uses. To determine the manufacturing conditions of the film, we examined the influence of additives, triphenylphosphate (TPP) and others, and film thickness on the dosimetric properties, since these two conditions remarkably influence the sensitivity of the dose meter. It is necessary for the reliability of plastic dose meters that the radiation induced colorations should be understood as radiation chemical processes. In this paper we describe the determination of the manufacturing conditions of the new film, the feature of the new dose meter, and the coloration mechanism. (author)

  18. Applications of Pitot-meter techniques in two-phase, steam/water, flow

    International Nuclear Information System (INIS)

    Kastner, W.; Manzano-Ruiz, J.J.

    1985-01-01

    A simple technique, based on the interpretation of dynamic-pressure readings obtained with local and averaging Pitot-meters (APM) in tow-phase flow, is described and analyzed. The mean dynamic-pressure measurements obtained with an APM allow the calculation of the mass flux of the mixture if the steam quality is known and a combination of two slip-factor correlations is used. The local dynamic-pressure measurements with a multiple Pitot-probe technique provide information on the transition between the most commonly found flow patterns in horizontal piping, i.e. stratified, annular and annular-mist flow

  19. Digital Receiver Phase Meter

    Science.gov (United States)

    Marcin, Martin; Abramovici, Alexander

    2008-01-01

    The software of a commercially available digital radio receiver has been modified to make the receiver function as a two-channel low-noise phase meter. This phase meter is a prototype in the continuing development of a phase meter for a system in which radiofrequency (RF) signals in the two channels would be outputs of a spaceborne heterodyne laser interferometer for detecting gravitational waves. The frequencies of the signals could include a common Doppler-shift component of as much as 15 MHz. The phase meter is required to measure the relative phases of the signals in the two channels at a sampling rate of 10 Hz at a root power spectral density measurements in laser metrology of moving bodies. To illustrate part of the principle of operation of the phase meter, the figure includes a simplified block diagram of a basic singlechannel digital receiver. The input RF signal is first fed to the input terminal of an analog-to-digital converter (ADC). To prevent aliasing errors in the ADC, the sampling rate must be at least twice the input signal frequency. The sampling rate of the ADC is governed by a sampling clock, which also drives a digital local oscillator (DLO), which is a direct digital frequency synthesizer. The DLO produces samples of sine and cosine signals at a programmed tuning frequency. The sine and cosine samples are mixed with (that is, multiplied by) the samples from the ADC, then low-pass filtered to obtain in-phase (I) and quadrature (Q) signal components. A digital signal processor (DSP) computes the ratio between the Q and I components, computes the phase of the RF signal (relative to that of the DLO signal) as the arctangent of this ratio, and then averages successive such phase values over a time interval specified by the user.

  20. Calibration methodology application of kerma area product meters in situ: Preliminary results

    Science.gov (United States)

    Costa, N. A.; Potiens, M. P. A.

    2014-11-01

    The kerma-area product (KAP) is a useful quantity to establish the reference levels of conventional X-ray examinations. It can be obtained by measurements carried out with a KAP meter on a plane parallel transmission ionization chamber mounted on the X-ray system. A KAP meter can be calibrated in laboratory or in situ, where it is used. It is important to use one reference KAP meter in order to obtain reliable quantity of doses on the patient. The Patient Dose Calibrator (PDC) is a new equipment from Radcal that measures KAP. It was manufactured following the IEC 60580 recommendations, an international standard for KAP meters. This study had the aim to calibrate KAP meters using the PDC in situ. Previous studies and the quality control program of the PDC have shown that it has good function in characterization tests of dosimeters with ionization chamber and it also has low energy dependence. Three types of KAP meters were calibrated in four different diagnostic X-ray equipments. The voltages used in the two first calibrations were 50 kV, 70 kV, 100 kV and 120 kV. The other two used 50 kV, 70 kV and 90 kV. This was related to the equipments limitations. The field sizes used for the calibration were 10 cm, 20 cm and 30 cm. The calibrations were done in three different cities with the purpose to analyze the reproducibility of the PDC. The results gave the calibration coefficient for each KAP meter and showed that the PDC can be used as a reference instrument to calibrate clinical KAP meters.

  1. Energy saving by smart metering with consumption feedback; Energieeinsparung durch Smart Metering mit Verbrauchs-Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Patrick [Institut fuer ZukunftsEnergieSysteme (IZES), Saarbruecken (Germany); Friedrich, Malte [Institut fuer Soziologische Meinungsforschung (IsoMe), Berlin (Germany); Kerber-Clasen, Stefan [Institut fuer Sozialforschung und Sozialwirtschaft e.V., Saarbruecken (Germany); Frey, Guenther

    2012-08-15

    While the German legislative, e.g. in the EnWG (Power Industry Act) assumes that electricity consumption metering will contribute to energy conservation in any case, many studies have arrived at a different contribution: Only a combination of consumption metering and direct feedback methods will result in significant energy savings. A recent research project (''Moderne Energiesparsysteme fuer Haushalte'') analysed an energy conservation system of this type. The findings will provide socio-economic insight into the background of successful energy conservation, and they will show how feedback methods can be optimised.

  2. Smart meter deployment optimisation and its analysis for appliance load monitoring

    Directory of Open Access Journals (Sweden)

    Ahmed Shaharyar Khwaja

    2015-04-01

    Full Text Available In this study, the authors study the problem of smart meter deployment optimisation for appliance load monitoring, that is, to monitor a number of devices without any ambiguity using the minimum number of low-cost smart meters. The importance of this problem is due to the fact that the number of meters should be reduced to decrease the deployment cost, improve reliability and decrease congestion. In this way, in future, smart meters can provide additional information about the type and number of distinct devices connected, besides their normal functionalities concerned with providing overall energy measurements and their communication. The authors present two exact smart meter deployment optimisation algorithms, one based on exhaustive search and the other based on efficient implementation of the exhaustive search. They formulate the problem mathematically and present computational complexity analysis of their algorithms. Simulation scenarios show that for a typical number of home appliances, the efficient search method is significantly faster compared to the exhaustive search and can provide the same optimal solution. The authors also show the dependency of their method on the distribution of the load pattern that can potentially be in a typical household.

  3. Metering instrument of quality factor Q of gravitational wave antenna

    International Nuclear Information System (INIS)

    Jia-yan, C.; Tong-ren, G.

    1982-01-01

    The quality factor, Q, of gravitational wave antenna depends on the material property as well as external conditions, such as temperature, residual pressure in vacuum tank, support type, additional loss from transducer on antenna, etc. In order to find out the relationship between the antenna Q and external conditions automatical operating in succession is required. The authors have designed and made a metering instrument for quality factor Q. The metering instrument of Q can measure Q of the metal cylinder and other bar of higher Q. It can give data of the measurement at regular intervals as desired. It can measure accurately the longitudinal fundamental mode frequency of the cylinder with a digital frequency meter record oscillating signal from metering instrument. Because the metering instrument excites free-vibration of the cylinder with free-running type and keep up the stationary amplitude for a long time. (Auth.)

  4. Análisis CFD sobre la influencia de la solidez en aerogeneradores H-Darrieus con perfiles asimétricos NACA 7425

    OpenAIRE

    Rivero Sánchez, Alonso

    2016-01-01

    El presente trabajo de fin de grado es un estudio CFD de un aerogenerador de eje vertical tipo H-Darrieus de pequeñas dimensiones, compuesto por tres álabes con perfiles asimétricos NACA 7425. El objetivo principal es analizar la influencia de la solidez en un aerogenerador con estas características, para ello se estudiaran diferentes modelos posibles, rotor completo y perfiles estáticos. En la práctica se han realizado diversas simulaciones para llegar a obtener las curvas características de...

  5. Seismic-induced accelerations detected by two parallel gravity meters in continuous recording with a high sampling rate at Etna volcano

    Directory of Open Access Journals (Sweden)

    P. Stefanelli

    2008-06-01

    Full Text Available We analyse a microgravity data set acquired from two spring LaCoste & Romberg gravity meters operated in parallel at the same site on Etna volcano (Italy for about two months (August – September 2005. The high sampling rate acquisition (2Hz allowed the correlation of short-lasting gravity fluctuations with seismic events. After characterizing the oscillation behavior of the meters, through the study of spectral content and the background noise level of both sequences, we recognized fluctuations in the gravity data, spanning a range of periods from 1 second to about 30 seconds dominated by components with a period of about 15 ÷ 25 seconds, during time intervals encompassing both local seismic events and large worldwide earthquakes. The data analyses demonstrate that observed earthquake-induced gravity fluctuations have some differences due to diverse spectral content of the earthquakes. When local seismic events which present high frequency content excite the meters, the correlation between the two gravity signals is poor (factor < 0.3. Vice versa, when large worldwide earthquakes occur and low frequency seismic waves dominate the ensuing seismic wavefield, the resonance frequencies of the meters are excited and they react according to more common features. In the latter case, the signals from the two instruments are strongly correlated to each other (up to 0.9. In this paper the behaviors of spring gravimeters in the frequency range of the disturbances produced by local and large worldwide earthquakes are presented and discussed.

  6. Smart metering - energy data management at every meter point; Smart Metering - Energiedatenmanagement an jedem Zaehlpunkt

    Energy Technology Data Exchange (ETDEWEB)

    Keller-Giessbach, D.; Kiel, E. [LogicaCMG, Muenchen (Germany)

    2007-09-15

    The demise of monopolistic structures in the German energy market has also led to a change of perspective on metering. New requirements have to be met. Even in mass processing jobs such as meter reading it is no longer sufficient to simply read consumption data off a technically reliable meter or have customers do this themselves in preparation of billing. Currently used meters were not designed with a mind to demand management, environmental protection through energy conservation, changes in consumer behaviour or new service offers. This has been recognised in many European countries since the beginning of the present decade. The traditional task of metering is developing into a more comprehensive energy data management that takes account of the needs of customers, energy suppliers and regulatory requirements.

  7. Evaluation of different disinfectants on the performance of an on-meter dosed amperometric glucose-oxidase-based glucose meter.

    Science.gov (United States)

    Sarmaga, Don; Dubois, Jeffrey A; Lyon, Martha E

    2011-11-01

    Off-meter dosed photometric glucose-oxidase-based glucose meters have been reported to be susceptible to interference by hydrogen-peroxide-based disinfecting agents. The objective of this study was to determine if a single application of hydrogen-peroxide-containing Accel® wipe to disinfect an on-meter dosed amperometric glucose-oxidase-based glucose meter will influence its performance. The performance of five on-meter dosed amperometric glucose-oxidase-based glucose meters was determined before and after disinfecting the devices with a single application of either CaviWipes® (14.3% isopropanol and 0.23% diisobutyl-phenoxy-ethoxyethyl dimethyl benzyl ammonium chloride) or Accel (0.5% hydrogen peroxide) wipes. Replicate glucose measurements were conducted before disinfecting the devices, immediately after disinfecting, and then 1 and 2 min postdisinfecting, with measurements in triplicate. Analysis was sequentially completed for five different meters. Results were analyzed by a two-way analysis of variance (Analyze-it software). No clinical ( .05) in glucose concentration were detected when the on-meter dosed amperometric glucose-oxidase-based glucose meters were disinfected with either CaviWipes or Accel wipes and measured immediately or 1 or 2 min postdisinfecting. No clinically significant difference in glucose concentration was detected between meters (glucose oxidase amperometric-based glucose meters are not analytically susceptible to interference by a single application of hydrogen-peroxide-containing Accel disinfectant wipes. © 2011 Diabetes Technology Society.

  8. Radio-controlled automatic gas meter-reading system; Releve automatique de compteur par radio

    Energy Technology Data Exchange (ETDEWEB)

    Yasui, M. [Osaka Gas Co., Ltd (Japan); Ishikawa, K.; Fujiwara, J. [Tokyo Gas Co., Ltd. (Japan); Ichihashi, T. [Toho Gas Co., Ltd. (Japan)

    2000-07-01

    In Japan, an automatic gas meter-reading system is in operation, also incorporating the functions of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff. This system has been realized by linking microcomputer-controlled gas meters(It's called 'Intelligent gas mater') equipped with automatic shutoff mechanism to the gas utility company operation center via communication lines. While the present system uses cable communication lines, we of Tokyo Gas Co., Ltd., Osaka Gas Co., Ltd. and Toho Gas Co., Ltd., have jointly developed a new system based on radio communication. This paper introduces this new system. While radio-controlled meter-reading systems are used in many countries around the world solely for automatic meter reading, our recently developed system is also capable of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff, thanks to its almost real-time two-way communication function. The new system can serve for a period of ten years without recharging. It is also characterized by its applicability as different systems according to purposes: 1) conventional automatic meter-reading system (terminal network control unit or T-NCU), 2) large-scale radio-controlled meter-reading system, and 3) portable terminal-type radio-controlled meter-reading system. (authors)

  9. Sagnac interferometer as a speed-meter-type, quantum-nondemolition gravitational-wave detector

    International Nuclear Information System (INIS)

    Chen Yanbei

    2003-01-01

    According to quantum measurement theory, 'speed meters' - devices that measure the momentum, or speed, of free test masses - are immune to the standard quantum limit (SQL). It is shown that a Sagnac-interferometer gravitational-wave detector is a speed meter and therefore in principle it can beat the SQL by large amounts over a wide band of frequencies. It is shown, further, that, when one ignores optical losses, a signal-recycled Sag nac interferometer with Fabry-Perot arm cavities has precisely the same performance, for the same circulating light power, as the Michelson speed-meter interferometer recently invented and studied by Purdue and the author. The influence of optical losses is not studied, but it is plausible that they be fairly unimportant for the Sag nac interferometer, as for other speed meters. With squeezed vacuum (squeeze factor e -2R =0.1) injected into its dark port, the recycled Sag nac interferometer can beat the SQL by a factor √(10)≅3 over the frequency band 10 Hz c ∼820 kw as is to be used by the (quantum limited) second-generation Advanced LIGO interferometers--if other noise sources are made sufficiently small. It is concluded that the Sag nac optical configuration, with signal recycling and squeezed-vacuum injection, is an attractive candidate for third-generation interferometric gravitational-wave detectors (LIGO-III and EURO)

  10. Fabrication and evaluation of a graphene oxide-based cantilever-type flow-meter for subsonic gas flow rate measurement

    Science.gov (United States)

    Hamdollahi, Hassan; Rahbar-Shahrouzi, Javad

    2018-05-01

    In this paper, a cantilever-type flow meter was fabricated to measure the rate of air flow in turbulent subsonic regimes such as purged gases. In the fabrication process, a piezoresistive material was coated on an interdigitated electric board as a substrate. The piezoresistive layer was a blend of latex as the polymeric matrix and graphene oxide as the sensing nanomaterial agent, which was reduced by solvothermal reduction method. The piezoresistive blend was dip-coated on a substrate with dotted pattern and was then reduced at 240 °C for 1 h in every coating step. When an air flow passed over the surface of the cantilever beam, the beam was bent in the downward direction, resulting in small variations in the resistance of the piezoresistive layer and a change in the bending angle of the cantilever which were measured simultaneously. The air flow rate was acquired via calibrating electrical resistance changes by Arduino and Wheatstone bridge circuit. The blending angle of the substrate caused by the interaction between the airflow and the cantilever and recorded by the camera and image processing was ultimately compared with the simulation results. The flow meter accuracy as a percentage of full scale (% FS) was calculated to be  ±5.8%, and mean deviation was equal to 2.1 (% FS) with the appropriate response time of 0.70 s at the air flow range of 100‑240 m s‑1. Highlights • A cantilever-type flow meter was fabricated to measure the high-speed air flow rate. • The sensitive piezoresistive material was composed of GO and latex. • The dip-coating method was used to deposit the piezoresistive layer on the fiberglass substrate. • The impact of effective parameters on the performance of the flow meter was investigated. • A simulation study was performed and the results were compared with the experimental data.

  11. Adaptation of the DP 50 dust meter for measuring dust content under isokinetic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Vitek, J.; Novak, L.

    1985-03-01

    The DP 50 dust meter, developed by the Scientific Coal Research Institute Ostrava-Radvanice, is used for measuring dust content in the air in underground coal mines. Two versions of the system are used: a type developed in 1970 which is placed in a vertical position and used to measure the content of respirable coal particles in the air; and a type developed in 1983 for isokinetic measurement of dust content in the air. The latter is equipped with 8 cone-shaped adapters (with differing size and dimensions of the cone inlet adjusted to air flow rates from 0.25 to 8.00 m/s). Specifications of the 8 adapters are given in a table. The 1983 version of the DP 50 is placed in a horizontal position with the dust meter axis parallel to the direction of air flow ventilating a mine working. Recommendations for installation of dust meters in underground workings and effects of installation on measurement accuracy are discussed. 16 references.

  12. Smart Metering. Technological, economic and legal aspects. 2. ed.; Smart Metering. Technologische, wirtschaftliche und juristische Aspekte des Smart Metering

    Energy Technology Data Exchange (ETDEWEB)

    Koehler-Schute, Christiana (ed.)

    2010-07-01

    Smart metering comprises more than just meter technology, and the use of information and communication technologies is indispensable. Processes, roles and business models must be reconsidered as further challenges arise in the context of smart metering. For one, there is the operator of the metering points. Secondly, there is the end user who is in the role of an active market partner. Further, there is smart metering as a basic technology, e.g. for smart grids and smart homes. In spite of the need for action, many utilities are reluctant to introduce smart metering. Reasons for this are the cost, a lack of defined standards, and an unclear legal situation. On the other hand, smart metering offers potential for grids and distribution that should be made use of. The authors discuss all aspects of the subject. The point out the chances and limitations of smart metering and present their own experience. [German] Smart Metering geht weit ueber die Zaehlertechnologie hinaus und der Einsatz von Informations- und Kommunikationstechnologien ist unabdingbar. Damit einhergehend muessen Prozesse, Rollen und auch Geschaeftsmodelle neu durchdacht werden. Denn weitere Herausforderungen stehen im direkten Zusammenhang mit Smart Metering. Das ist zum einen die Rolle des Messstellenbetreibers / Messdienstleisters. Das ist zum anderen der Endnutzer, dem die Rolle des aktiven Marktpartners zugedacht wird. Das ist des Weiteren das Smart Metering als Basistechnologie beispielsweise fuer Smart Grid und Smart Home. Trotz des Handlungsdrucks stehen viele Unternehmen der Energiewirtschaft dem Smart Metering zurueckhaltend gegenueber. Drei gewichtige Gruende werden ins Feld gefuehrt: die Kostenfrage, nicht definierte Standards und die in vielen Bereichen ungeklaerte Gesetzeslage. Demgegenueber bietet das Smart Metering Potenziale fuer Netz und Vertrieb, die es zu nutzen gilt. Die Autoren setzen sich in ihren Beitraegen mit diesen Themen auseinander, zeigen Chancen, aber auch Grenzen des

  13. Microprocessor controlled digital period meter

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1980-01-01

    A microprocessor controlled digital period meter has been developed and tested operationally on a reactor at Argonne National Laboratory. The principle of operation is the mathematical relationship between asymptotic periods and pulse counting circuitry. This relationship is used to calculate and display the reactor periods over a range of /plus or minus/1 second to /plus or minus/999 seconds. The time interval required to update each measurement automatically varies from 8 seconds at the lowest counting rates to 2 seconds at higher counting rates. The paper will describe hardware and software design details and show the advantages of this type of Period Meter over the conventional circuits. 1 ref

  14. Model tests of wind turbine with a vertical axis of rotation type Lenz 2

    Directory of Open Access Journals (Sweden)

    Zwierzchowski Jaroslaw

    2017-01-01

    Full Text Available A building design of vertical axis wind turbines (VAWT was presented in the article. The construction and operating principle of a wind turbine were described therein. Two VAWT turbine models were compared, i.a. Darrieus and Lenz2, taking their strengths and weaknesses into consideration. 3D solid models of turbine components were presented with the use of SolidWorks software. Using CFD methods, the air flow on two aerodynamic fins, symmetrical and asymmetrical, at different angles of attack were tested. On the basis of flow simulation conducted in FlowSimulation, an asymmetrical fin was chosen as the one showing greater load bearing capacities. Due to the uncertainty of trouble-free operation of Darrieus turbine on construction elements creating the basis thereof, a 3D model of Lenz2 turbine was constructed, which is more reliable and makes turbine self-start possible. On the basis of the research, components were designed and technical docu mentation was compiled.

  15. Model tests of wind turbine with a vertical axis of rotation type Lenz 2

    Science.gov (United States)

    Zwierzchowski, Jaroslaw; Laski, Pawel Andrzej; Blasiak, Slawomir; Takosoglu, Jakub Emanuel; Pietrala, Dawid Sebastian; Bracha, Gabriel Filip; Nowakowski, Lukasz

    A building design of vertical axis wind turbines (VAWT) was presented in the article. The construction and operating principle of a wind turbine were described therein. Two VAWT turbine models were compared, i.a. Darrieus and Lenz2, taking their strengths and weaknesses into consideration. 3D solid models of turbine components were presented with the use of SolidWorks software. Using CFD methods, the air flow on two aerodynamic fins, symmetrical and asymmetrical, at different angles of attack were tested. On the basis of flow simulation conducted in FlowSimulation, an asymmetrical fin was chosen as the one showing greater load bearing capacities. Due to the uncertainty of trouble-free operation of Darrieus turbine on construction elements creating the basis thereof, a 3D model of Lenz2 turbine was constructed, which is more reliable and makes turbine self-start possible. On the basis of the research, components were designed and technical docu mentation was compiled.

  16. Flow Over a Body of Revolution in a Steady Turn

    Science.gov (United States)

    2004-10-01

    31], Migliore and Wolfe [32]. Migliore investigated flow curvature effects on Darrieus wind turbines , a special type of turbine which has a continuous...and Wolfe- J. B.. Some Effects of Flow Curvature Effects oil the Aerodynamics of Darrieus Wind Turbines West Viryinia University , 1979 33. Hirsch, Ch...and Mandal. A. C., Flow Curvature Effects on Vertical Axis Darrieus Wind Turbine Having High Chord-Radius Ratio European Wind Energy Confer- ence

  17. A 34-meter VAWT (Vertical Axis Wind Turbine) point design

    Science.gov (United States)

    Ashwill, T. D.; Berg, D. E.; Dodd, H. M.; Rumsey, M. A.; Sutherland, H. J.; Veers, P. S.

    The Wind Energy Division at Sandia National Laboratories recently completed a point design based on the 34-m Vertical Axis Wind Turbine (VAWT) Test Bed. The 34-m Test Bed research machine incorporates several innovations that improve Darrieus technology, including increased energy production, over previous machines. The point design differs minimally from the Test Bed; but by removing research-related items, its estimated cost is substantially reduced. The point design is a first step towards a Test-Bed-based commercial machine that would be competitive with conventional sources of power in the mid-1990s.

  18. Electricity Consumption Clustering Using Smart Meter Data

    Directory of Open Access Journals (Sweden)

    Alexander Tureczek

    2018-04-01

    Full Text Available Electricity smart meter consumption data is enabling utilities to analyze consumption information at unprecedented granularity. Much focus has been directed towards consumption clustering for diversifying tariffs; through modern clustering methods, cluster analyses have been performed. However, the clusters developed exhibit a large variation with resulting shadow clusters, making it impossible to truly identify the individual clusters. Using clearly defined dwelling types, this paper will present methods to improve clustering by harvesting inherent structure from the smart meter data. This paper clusters domestic electricity consumption using smart meter data from the Danish city of Esbjerg. Methods from time series analysis and wavelets are applied to enable the K-Means clustering method to account for autocorrelation in data and thereby improve the clustering performance. The results show the importance of data knowledge and we identify sub-clusters of consumption within the dwelling types and enable K-Means to produce satisfactory clustering by accounting for a temporal component. Furthermore our study shows that careful preprocessing of the data to account for intrinsic structure enables better clustering performance by the K-Means method.

  19. Usage and conditions of radiation protection of nuclear meters in Brazil

    International Nuclear Information System (INIS)

    Guimarães, E.F.; Silva, F.C.A. da

    2017-01-01

    The industries of mining, pulp, oil, etc. which require a quality control in the processes, use the nuclear meters with sealed radioactive sources coupled to a radiation detector that generate accurate and fast answers regarding the level, thickness, density and humidity of different types of materials. Nuclear meters are classified as fixed or portable and use transmission, backscatter or reactive systems. As they use radioactive sources with various ranges of activities, they are classified by the International Atomic Energy Agency - AIEA as Category 3 and 4, of medium and low radiological risk, and must therefore have a suitable level of radiation protection for safe use in the installation. The Brazilian National Energy Commission - CNEN controls approximately 500 authorized facilities with nuclear meters. The paper technically describes the nuclear meters and the radiological protection procedures that must be followed for the safety of the IOEs (occupationally exposed individuals) and individuals from the public, based on the specific nuclear meter test program for CNEN radiation protection supervisor. The professionals who handle these nuclear meters should be aware of the radiological risk to their own protection and to individuals in the public. For safe operation with nuclear meters, a number of requirements must be observed according to the type and need of the installation

  20. Balanced Flow Meters without Moving Parts

    Science.gov (United States)

    Kelley, Anthony R.; VanBuskirk, Paul

    2008-01-01

    Balanced flow meters are recent additions to an established class of simple, rugged flow meters that contain no moving parts in contact with flow and are based on measurement of pressure drops across objects placed in flow paths. These flow meters are highly accurate, minimally intrusive, easily manufacturable, and reliable. A balanced flow meter can be easily mounted in a flow path by bolting it between conventional pipe flanges. A balanced flow meter can be used to measure the flow of any of a variety of liquids or gases, provided that it has been properly calibrated. Relative to the standard orifice-plate flow meter, the balanced flow meter introduces less turbulence and two times less permanent pressure loss and is therefore capable of offering 10 times greater accuracy and repeatability with less dissipation of energy. A secondary benefit of the reduction of turbulence is the reduction of vibration and up to 15 times less acoustic noise generation. Both the balanced flow meter and the standard orifice-plate flow meter are basically disks that contain holes and are instrumented with pressure transducers on their upstream and downstream faces. The most obvious difference between them is that the standard orifice plate contains a single, central hole while the balanced flow meter contains multiple holes. The term 'balanced' signifies that in designing the meter, the sizes and locations of the holes are determined in an optimization procedure that involves balancing of numerous factors, including volumetric flow, mass flow, dynamic pressure, kinetic energy, all in an effort to minimize such undesired effects as turbulence, pressure loss, dissipation of kinetic energy, and non-repeatability and nonlinearity of response over the anticipated range of flow conditions. Due to proper balancing of these factors, recent testing demonstrated that the balanced flow-meter performance was similar to a Venturi tube in both accuracy and pressure recovery, but featured reduced

  1. Smart meter implementation plan : report of the Board to the Minister

    International Nuclear Information System (INIS)

    2005-01-01

    This report provides detailed information about Ontario's smart meter implementation plan. The smart metering system will measure how much electricity a customer uses on an hourly basis, with data being transferred daily to local electricity distributors. Energy prices will vary according to the time of day when energy was being consumed, a system that supports current methods of charging larger customers. The plan proposes that all new and existing customers in Ontario have some type of smart meter by 2010 as part of a two-phased plan. Customers will receive timely information on consumption, and distributors will offer variable pricing plans. It was advised that costs be included in the distribution rate immediately upon installation of smart meters. Detailed information on implementation, smart metering costs, minimum requirements, and non-commodity time of use rates were presented. Critical tasks for establishing a framework for implementation included: ministerial approval of the plan; identification of a program coordinator; the establishment of a correct regulatory framework; a vendor approval process requiring appropriate permissions for radio frequency licences; technology pilots on behalf of distributors to assure adequate adaptation and the development of procedures concerning procurement, internal schedules and deployment; coordination between government, regulatory bodies and distributors towards the establishment of communication strategies, implementation plans and distributor approaches. 5 tabs., 6 figs

  2. Prospects for development of wind turbines with orthogonal rotor

    Science.gov (United States)

    Gorelov, D. N.; Krivospitsky, V. P.

    2008-03-01

    The experimental data obtained previously on the investigation of power characteristics and the possibility of the self-start of the Darrieus rotor are anlysed. These results are used at the design of new two-tier wind turbines with straight blades. The full-scale tests of two design variants showed the prospects for the development of wind turbines with the Darrieus rotor. At a reasonable design, they do not need any devices for the rotor orientation and start-up, are little sensitive to wind gusts and can have a high level of power characteristics, which is not inferior to the best samples of the units of propeller type.

  3. Comparison of five portable peak flow meters.

    Science.gov (United States)

    Takara, Glaucia Nency; Ruas, Gualberto; Pessoa, Bruna Varanda; Jamami, Luciana Kawakami; Di Lorenzo, Valéria Amorim Pires; Jamami, Mauricio

    2010-05-01

    To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone, Assess, Galemed, Personal Best and Vitalograph peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (pmeters were 428 (263-688 L/min), 450 (350-800 L/min), 420 (310-720 L/min), 380 (300-735 L/min), 400 (310-685 L/min) and 415 (335-610 L/min), respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone(R) (pmeters. There was no agreement between the spirometric values and the five PEF meters. The results suggest that the values recorded from Galemed meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  4. Development of quick-response area-averaged void fraction meter

    International Nuclear Information System (INIS)

    Watanabe, Hironori; Iguchi, Tadashi; Kimura, Mamoru; Anoda, Yoshinari

    2000-11-01

    Authors are performing experiments to investigate BWR thermal-hydraulic instability under coupling of neutronics and thermal-hydraulics. To perform the experiment, it is necessary to measure instantaneously area-averaged void fraction in rod bundle under high temperature/high pressure gas-liquid two-phase flow condition. Since there were no void fraction meters suitable for these requirements, we newly developed a practical void fraction meter. The principle of the meter is based on the electrical conductance changing with void fraction in gas-liquid two-phase flow. In this meter, metal flow channel wall is used as one electrode and a L-shaped line electrode installed at the center of flow channel is used as the other electrode. This electrode arrangement makes possible instantaneous measurement of area-averaged void fraction even under the metal flow channel. We performed experiments with air/water two-phase flow to clarify the void fraction meter performance. Experimental results indicated that void fraction was approximated by α=1-I/I o , where α and I are void fraction and current (I o is current at α=0). This relation holds in the wide range of void fraction of 0∼70%. The difference between α and 1-I/I o was approximately 10% at maximum. The major reasons of the difference are a void distribution over measurement area and an electrical insulation of the center electrode by bubbles. The principle and structure of this void fraction meter are very basic and simple. Therefore, the meter can be applied to various fields on gas-liquid two-phase flow studies. (author)

  5. Flow-Signature Analysis of Water Consumption in Nonresidential Building Water Networks Using High-Resolution and Medium-Resolution Smart Meter Data: Two Case Studies

    Science.gov (United States)

    Clifford, Eoghan; Mulligan, Sean; Comer, Joanne; Hannon, Louise

    2018-01-01

    Real-time monitoring of water consumption activities can be an effective mechanism to achieve efficient water network management. This approach, largely enabled by the advent of smart metering technologies, is gradually being practiced in domestic and industrial contexts. In particular, identifying water consumption habits from flow-signatures, i.e., the specific end-usage patterns, is being investigated as a means for conservation in both the residential and nonresidential context. However, the quality of meter data is bivariate (dependent on number of meters and data temporal resolution) and as a result, planning a smart metering scheme is relatively difficult with no generic design approach available. In this study, a comprehensive medium-resolution to high-resolution smart metering program was implemented at two nonresidential trial sites to evaluate the effect of spatial and temporal data aggregation. It was found that medium-resolution water meter data were capable of exposing regular, continuous, peak use, and diurnal patterns which reflect group wide end-usage characteristics. The high-resolution meter data permitted flow-signature at a personal end-use level. Through this unique opportunity to observe water usage characteristics via flow-signature patterns, newly defined hydraulic-based design coefficients determined from Poisson rectangular pulse were developed to intuitively aid in the process of pattern discovery with implications for automated activity recognition applications. A smart meter classification and siting index was introduced which categorizes meter resolution in terms of their suitable application.

  6. Alternative Energy Sources for United States Air Force Installations

    Science.gov (United States)

    1975-08-01

    applications were developed for the vertical- axis rotor, the concept never became popular. Interest was renewed in the Darrieus type wind turbine when the...chordwise lift force is greater than the chorcwise drag force (ref. 30). The Darrieus wind turbine offers the follwing advantages relative to the more...Laboratories, New Mexico, May 1974. 105 lAFWL-TR-75- 193 REFERENCES (Cont’d) 32. Banas, J. F., et al., Application of Darrieus Vertical - Axis Wind Turbine to

  7. Comparison of five portable peak flow meters

    Directory of Open Access Journals (Sweden)

    Glaucia Nency Takara

    2010-01-01

    Full Text Available OBJECTIVE: To compare the measurements of spirometric peak expiratory flow (PEF from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. METHODS: Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05, Spearman's correlation test and Bland-Altman's agreement test. RESULTS: The median and interquartile ranges for the spirometric values and the Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® meters were 428 (263-688 L/min, 450 (350-800 L/min, 420 (310-720 L/min, 380 (300-735 L/min, 400 (310-685 L/min and 415 (335-610 L/min, respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone® (p<0.001 and Galemed ® (p<0.01 meters. There was no agreement between the spirometric values and the five PEF meters. CONCLUSIONS: The results suggest that the values recorded from Galemed® meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone® meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  8. Development of the impedance void meter

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Moon Ki; Song, Chul Hwa; Won, Soon Yeon; Kim, Bok Deuk [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-06-01

    An impedance void meter is developed to measure the area-averaged void fraction. Its basic principle is based on the difference in the electrical conductivity between phases. Several methods of measuring void fraction are briefly reviewed and the reason why this type of void meter is chosen to develop is discussed. Basic principle of the measurement is thoroughly described and several design parameters to affect the overall function are discussed in detail. As example of applications is given for vertical air-water flow. It is shown that the current design has good dynamic response as well as very fine spatial resolution. (Author) 47 refs., 37 figs.

  9. 77 FR 40586 - Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter...

    Science.gov (United States)

    2012-07-10

    ...-01] Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter... Technology (NIST) seeks comments on Draft NISTIR 7823, Advanced Metering Infrastructure Smart Meter... conformance test requirements for the firmware upgradeability process for the Advanced Metering Infrastructure...

  10. Nuclear Enterprises portable dose rate meter type PDR 2

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    This instrument is a portable battery powered dose rate meter covering the dose rate range from 0.05 to 500 mrad h -1 . It is designed to measure X- and γ-radiation dose rates over the energy range from 35 keV to 3 MeV. The radiation detector is an MX 164/S GM tube provided with a compensation sheath. The report describes the instrument under the headings: facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; the manual; summary of performance. (U.K.)

  11. New, small, fast acting blood glucose meters--an analytical laboratory evaluation.

    Science.gov (United States)

    Weitgasser, Raimund; Hofmann, Manuela; Gappmayer, Brigitta; Garstenauer, Christa

    2007-09-22

    Patients and medical personnel are eager to use blood glucose meters that are easy to handle and fast acting. We questioned whether accuracy and precision of these new, small and light weight devices would meet analytical laboratory standards and tested four meters with the above mentioned conditions. Approximately 300 capillary blood samples were collected and tested using two devices of each brand and two different types of glucose test strips. Blood from the same samples was used for comparison. Results were evaluated using maximum deviation of 5% and 10% from the comparative method, the error grid analysis, the overall deviation of the devices, the linear regression analysis as well as the CVs for measurement in series. Of all 1196 measurements a deviation of less than 5% resp. 10% from the reference method was found for the FreeStyle (FS) meter in 69.5% and 96%, the Glucocard X Meter (GX) in 44% and 75%, the One Touch Ultra (OT) in 29% and 60%, the Wellion True Track (WT) in 28.5% and 58%. The error grid analysis gave 99.7% for FS, 99% for GX, 98% for OT and 97% for WT in zone A. The remainder of the values lay within zone B. Linear regression analysis resembled these results. CVs for measurement in series showed higher deviations for OT and WT compared to FS and GX. The four new, small and fast acting glucose meters fulfil clinically relevant analytical laboratory requirements making them appropriate for use by medical personnel. However, with regard to the tight and restrictive limits of the ADA recommendations, the devices are still in need of improvement. This should be taken into account when the devices are used by primarily inexperienced persons and is relevant for further industrial development of such devices.

  12. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    Science.gov (United States)

    Darghouth, Naim Richard

    Net metering has become a widespread policy mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), allowing customers with PV systems to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption. Although net metering is one of the principal drivers for the residential PV market in the U.S., the academic literature on this policy has been sparse and this dissertation contributes to this emerging body of literature. This dissertation explores the linkages between the availability of net metering, wholesale electricity market conditions, retail rates, and the residential bill savings from behind-the-meter PV systems. First, I examine the value of the bill savings that customers receive under net metering and alternatives to net metering, and the associated role of retail rate design, based on current rates and a sample of approximately two hundred residential customers of California's two largest electric utilities. I find that the bill savings per kWh of PV electricity generated varies greatly, largely attributable to the increasing block structure of the California utilities' residential retail rates. I also find that net metering provides significantly greater bill savings than alternative compensation mechanisms based on avoided costs. However, retail electricity rates may shift as wholesale electricity market conditions change. I then investigate a potential change in market conditions -- increased solar PV penetrations -- on wholesale prices in the short-term based on the merit-order effect. This demonstrates the potential price effects of changes in market conditions, but also points to a number of methodological shortcomings of this method, motivating my usage of a long-term capacity investment and economic dispatch model to examine wholesale price effects of various wholesale market scenarios in the subsequent analysis. By developing

  13. Smart meters. Smart metering. A solution module for a future-oriented energy system; Intelligente Zaehler. Smart Metering. Ein Loesungsbaustein fuer ein zukunftsfaehiges Energiesystem

    Energy Technology Data Exchange (ETDEWEB)

    Grimm, Nadia; Seidl, Hans [comps.

    2011-12-15

    The German Energy Agency GmbH (Berlin, Federal Republic of Germany) reports on smart metering as a solution module for a future-oriented energy system by means of the following contributions: (1) Key role for smart meters; (2) What is smart metering? (3) Implementation of smart metering in Europe; (4) The market development to date in Germany; (5) Practical experiences with smart metering in Germany; (6) Frequently asked questions; (7) Smart metering in intelligent networks; (8) Legal framework conditions; (9) Data security and data protection in the utilisation of smart meters; (10) Ongoing information; (11) Efficient energy systems.

  14. Beyond revenue metering -- a new age for automatic meter reading

    Energy Technology Data Exchange (ETDEWEB)

    Chebra, R. J. [RJC Consulting L.L.C., PQ (Canada)

    2002-10-01

    Advanced metering, data management, and communications possibilities of automated meter reading are explored. Applications in the area of demand side management, including load reduction, peak shaving and load shifting, new tariff structures based on the 'time of use incentive/penalty' approach, and information grade metering are emphasized. Based on trends and expectations, it is predicted that AMR will continue to experience rapid growth and deployment as new services are made available to the mass market. For example, technological advances will enable the industry to make 'time of use metering ' more attractive and beneficial to residential consumers, and embedded intelligence will make it possible to achieve more holistic energy environments.

  15. The Research on Metrological Characteristics of House Water Meters during Transitional Flow Regimes

    Directory of Open Access Journals (Sweden)

    Inga Briliūtė

    2011-04-01

    Full Text Available The purpose of this research is to find the influence of transitional flow regimes on inlet water meters. Four construction types of mechanical inlet water meters (each capacity Q = 10 m3/h were investigated. The biggest additional volume 0,12–0,26% when Q = 0,2…2 m3/h shows single-jet vane wheel meter. This additional volume is less 0,06–0,13% for the multi-jet concentric water meter. The minimum influence of transitional flow regimes was for turbine water meters till 0,1% for all flow range. The volumetric meters are not sensitive for this effect.Article in Lithuanian

  16. Development of quick-response area-averaged void fraction meter. Application to BWR condition

    Energy Technology Data Exchange (ETDEWEB)

    Iguchi, Tadashi; Watanabe, Hironori; Kimura, Mamoru; Anoda, Yoshinari [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-05-01

    Authors have been developed a practical conductance-type void fraction meter to measure instantaneously area-averaged void fraction in rod bundle. The principle of the meter is based on the fact that the electrical conductance changes with the change of void fraction in gas-liquid two-phase flow. According to air/water two-phase flow experiment, the void fraction was approximated by {alpha}=1-I/I{sub 0}, where {alpha} and I are void fraction and current (I{sub 0} is current at {alpha}=0). Authors investigated the performance of the void fraction meter under high temperature/high pressure conditions (BWR condition; 290degC, 7MPa). The results indicated that the void fraction was approximated by {alpha}=1-I/I{sub 0} even under high temperature/high pressure condition of stem/water flow. However, it is necessary to take account of temperature dependency of water specific conductance. Therefore, authors derived a correction equation for temperature dependency. Further, for applying the void fraction meter to a large-scale facility, it was found to be necessary to reduce the capacitance of the circuit. Then, authors developed the method to reduce the capacitance effect. Finally, authors succeeded to measure the void fraction in 2 x 2 bundle flow path at the range of 0% - 70% in the error of 10% under high temperature/high pressure and mass flux of less than 133 kg/m{sup 2}s. Developed void fraction meter is theoretically not affected by flow rate. Therefore, it can be applied to the condition of oscillating flow. (author)

  17. Radiofrequency energy exposure from the Trilliant smart meter.

    Science.gov (United States)

    Foster, Kenneth R; Tell, Richard A

    2013-08-01

    This paper reviews radiofrequency (RF) field levels produced by electric utility meters equipped with RF transceivers (so-called Smart Meters), focusing on meters from one manufacturer (Trilliant, Redwood City, CA, USA, and Granby, QC, Canada). The RF transmission levels are summarized based on publicly available data submitted to the U.S. Federal Communications Commission supplemented by limited independent measurements. As with other Smart Meters, this meter incorporates a low powered radiofrequency transceiver used for a neighborhood mesh network, in the present case using ZigBee-compliant physical and medium access layers, operating in the 2.45 GHz unlicensed band but with a proprietary network architecture. Simple calculations based on a free space propagation model indicate that peak RF field intensities are in the range of 10 mW m or less at a distance of more than 1-2 m from the meters. However, the duty cycle of transmission from the meters is very low (meter that were consistent with data reported by the vendor to the U.S. Federal Communications Commission. Limited measurements conducted in two houses with the meters were unable to clearly distinguish emissions from the meters from the considerable electromagnetic clutter in the same frequency range from other sources, including Wi-Fi routers and, when it was activated, a microwave oven. These preliminary measurements disclosed the difficulties that would be encountered in characterizing the RF exposures from these meters in homes in the face of background signals from other household devices in the same frequency range. An appendix provides an introduction to Smart Meter technology. The RF transmitters in wireless-equipped Smart Meters operate at similar power levels and in similar frequency ranges as many other digital communications devices in common use, and their exposure levels are very far below U.S. and international exposure limits.

  18. Gamin partable radiation meter with alarm threshold

    International Nuclear Information System (INIS)

    Payat, Rene.

    1981-10-01

    The Gamin Radiation meter is a direct reading, portable, battery-powered gamma doserate meter featuring alarm thresholds. Doserate is read on a micro-ammeter with a millirad-per-hour logarithmic scale, covering a range of 0,1 to 1000 millirads/hour. The instrument issues an audible warning signal when dose-rate level exceeds a threshold value, which can be selected. The detector tube is of the Geiger-Muller counter, energy compensated type. Because of its low battery drain, the instrument can be operated continously for 1000 hours. It is powered by four 1.5 volt alcaline batteries of the R6 type. The electronic circuitry is housed in a small lightweight case made of impact resistant plastic. Applications of the Gamin portable radiation monitor are found in health physics, safety departments, medical facilities, teaching, civil defense [fr

  19. Handheld Multi-Gas Meters Market Survey Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-23

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the chemical monitored. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. To provide emergency responders with information on handheld multi-gas meters, the System Assessment and Validation for Emergency Responders (SAVER) Program conducted a market survey. This market survey report is based on information gathered between November 2015 and February 2016 from vendors, Internet research, industry publications, an emergency responder focus group, and a government issued Request for Information (RFI) that was posted on the Federal Business Opportunities website.

  20. Assessment of the implementation regulations for smart meters; Beoordeling uitvoeringsregelingen Slimme Meter

    Energy Technology Data Exchange (ETDEWEB)

    Boekema, J.

    2011-03-15

    TNO (Netherlands) assessed whether the smart meter is reliable and future proof. By request of the Dutch Ministry of Economic Affairs, Agriculture and Innovation (ELI) an assessment was conducted of the requirements for smart meters and, as formulated in the Order in Council 'Decree on remotely readable metering devices', based on 48 tests regarding security, privacy and future stability. Taking into account a number of described recommendations, TNO deems the legislation and implementation schemes sufficient to allow for safe, reliable and future proof implementation of smart meters in the Netherlands. [Dutch] TNO heeft beoordeeld of de slimme meter betrouwbaar en toekomstvast is. Ten behoeve van het ministerie van Economische Zaken, Landbouw en Innovatie (ELI) zijn de eisen die aan slimme meters worden gesteld, en zoals verwoord in de AmvB 'Besluit op afstand uitleesbare meetinrichtingen', beoordeeld aan de hand van 48 toetsen over zekerheid (security), persoonlijke levenssfeer (privacy) en toekomstvastheid. Met inachtneming van een aantal omschreven aanbevelingen, vindt TNO wetgeving en uitvoeringsregelingen zodanig dat daarmee een veilige, betrouwbare en toekomstvaste slimme meter geimplementeerd kan worden in Nederland.

  1. Low Reynolds Number Vehicles

    Science.gov (United States)

    1985-02-01

    of the blade. The Darrieus VAWT has more complex aerodynamics. This type of wind turbine produces power as a result of the tangential thrust as...Horizontal Axis Propeller-Type b) Verticle Axis Darrieus -Type Figure 78. Wind Turbine Configurations 0 6 Q K [_ 2 -, C 4 UJ UJ...Sailplanes 23 5.2 Wind Turbines 23 6. CONCLUDING REMARKS 24 7. RECOMMENDATIONS FOR FUTURE RESEARCH 24 REFERENCES 25 FIGURES 32 yv/ LOW REYNOLDS NUMBER

  2. Polarization speed meter for gravitational-wave detection

    Science.gov (United States)

    Wade, Andrew R.; McKenzie, Kirk; Chen, Yanbei; Shaddock, Daniel A.; Chow, Jong H.; McClelland, David E.

    2012-09-01

    We propose a modified configuration of an advanced gravitational-wave detector that is a speed-meter-type interferometer with improved sensitivity with respect to quantum noise. With the addition of polarization-controlling components to the output of an arm cavity Michelson interferometer, an orthogonal polarization state of the interferometer can be used to store signal, returning it later with opposite phase to cancel position information below the storage bandwidth of the opposite mode. This modification provides an alternative to an external kilometer-scale Fabry-Pérot cavity, as presented in earlier work of Purdue and Chen [Phys. Rev. D 66, 122004 (2002)]. The new configuration requires significantly less physical infrastructure to achieve speed meter operation. The quantity of length and alignment degrees of freedom is also reduced. We present theoretical calculations to show that such a speed meter detector is capable of beating the strain sensitivity imposed by the standard quantum limit over a broad range of frequencies for Advanced Laser Interferometer Gravitational-wave Observatory-like parameters. The benefits and possible difficulties of implementing such a scheme are outlined. We also present results for tuning of the speed meter by adjusting the degree of polarization coupling, a novel possibility that does not exist in previously proposed designs, showing that there is a smooth transition from speed meter operation to that of a signal-recycling Michelson behavior.

  3. Portable wireless metering

    Energy Technology Data Exchange (ETDEWEB)

    DiPaola, L [Powtel Monitoring Systems, Inc., Ajax, ON (Canada)

    1996-12-31

    Portable meters were discussed as alternatives to standard billing meters for temporary installations. Current, voltage and power factor at a distribution station were measured to calculate kW and kVAR, using an easy to install product that communicates live readings directly to the existing billing system. A background of situations where temporary metering is a possible alternative to regular meters was presented. Use of electronic, clamp on Electronic Recording Ammeters (ERA) and their drawbacks were discussed. An improved temporary metering solution using FM radio transmission to deliver live data to a receiving device, the Eagle Series 3500, was introduced. Improvements over previous ERA systems were discussed, including accuracy, lack of batteries, immediate confirmation of functionality, current, voltage and power factor monitoring, direct feed to billing system, line crew savings, need for only a single unit at any given site, bi-directional power flow metering, independent report storage media, and a portable voltage and P.F. diagnostic tool. Details of trial applications at the Utopia distribution station west of Barrie, ON were presented. This technology was said to be still in the testing stage, but its flexibility and economy were sonsidered to be very promising for future application.

  4. Construction and calibration of high time resolution gas pressure meter

    International Nuclear Information System (INIS)

    Rossi, J.O.; Santos, C.; Ueda, M.

    1989-11-01

    In this report, the construction and calibration of a gas pressure meter with a time resolution better than 20 μs are described. The meter consists basically of a sensor of the FIG (Fast Ionization Gauge) type and an adequate electronic circuit. A 6AU6A pentode vacuum tube without the glass envelope is used as the sensor head. (author) [pt

  5. Smart metering. Conformance tests for electricity meters; Smart Metering. Konformitaetstests an Stromzaehlern

    Energy Technology Data Exchange (ETDEWEB)

    Bormann, Matthias; Pongratz, Siegfried [VDE Pruef- und Zertifizierungsinstitut, Offenbach (Germany)

    2012-07-01

    Introduction of communication technologies into today's energy network enables the interworking between the domains of smart metering, smart grid, smart home and e-mobility as well as the creation and provisioning of new innovative services such as efficient load adjustment. Due to this convergence the new energy networks are becoming increasingly complex. Ensuring the interworking between all network elements (e.g. electricity meters, gateways) in these smart energy networks is of utmost importance. To this end conformance and interoperability tests have to be defined to ensure that services work as expected. (orig.)

  6. New consumer services provided by smart metering

    Directory of Open Access Journals (Sweden)

    Daminov Ildar

    2015-01-01

    Full Text Available This paper focuses on the issues of smart metering market and considers different services provided by smart metering from consumer point of view. Firstly, smart metering deployment challenges emerging and conventional tariffs, which modify a consumer behavior and thus, the entire electric energy market can be optimized since the customer is motivated to consume less energy. Secondly, the authors illustrate changes in electricity quality, which have an impact on consumer relations with utility. Additionally, two main indices of grid resilience – SAIDI and SAIFI – are exemplified to reveal the improvement potential of smart metering implementation in certain regions of Russia that also influence the consumer. Finally, in-home display and privacy problem directly reflect the consumer’s behavior, thus the private life rights should not be violated as they are guaranteed by law.

  7. Technique of Hurdle Clearing in 400 Meters Hurdles

    OpenAIRE

    Jakoubek, Jiří

    2018-01-01

    Title: Technique of Hurdle Clearing in 400 Meters Hurdles Authors: Jiří Jakoubek Supervisor: PhDr. Aleš Kaplan, Ph.D. Aims: The aim of this thesis is to describe technique of hurdle clearing in 400 meters hurdle race using study review and to examine this technique at particular athlete during training and racing sessions in 400 meters hurdles race. Methods: Technique was compared and examined at young athlete. Two kinograms were used for analysis, one from training and one from racing sessio...

  8. The British Gas Quantum Metering System for pre-payment customers

    International Nuclear Information System (INIS)

    Williams, P.; Fitzpatrick, B.

    1992-01-01

    The development work leading up to the design of the Quantum Metering System is outlined. The main features of the meter including the reusable tokens, metering equipment, credit charging equipment, central controlling equipment and a portable token reader for field use are described in detail, and the two way communication of information is highlighted. (UK)

  9. Micro-gen metering solutions

    Energy Technology Data Exchange (ETDEWEB)

    Elland, J.; Dickson, J.; Cranfield, P.

    2003-07-01

    This report summarises the results of a project to investigate the regulation of domestic electricity metering work and identify the most economic options for micro-generator installers to undertake work on electricity meters. A micro-generation unit is defined as an energy conversion system converting non-electrical energy into electrical energy and can include technologies such as photovoltaic systems, small-scale wind turbines, micro-hydroelectric systems, and combined heat and power systems. Details of six tasks are given and cover examination of the existing framework and legal documentation for metering work, the existing technical requirements for meter operators, meter operator personnel accreditation, appraisal of options for meter changes and for micro-generation installation, document change procedures, industry consultation, and a review of the costs implications of the options.

  10. Sagnac interferometer as a speed-meter-type, quantum-nondemolition gravitational-wave detector

    Science.gov (United States)

    Chen, Yanbei

    2003-06-01

    According to quantum measurement theory, “speed meters”—devices that measure the momentum, or speed, of free test masses—are immune to the standard quantum limit (SQL). It is shown that a Sagnac-interferometer gravitational-wave detector is a speed meter and therefore in principle it can beat the SQL by large amounts over a wide band of frequencies. It is shown, further, that, when one ignores optical losses, a signal-recycled Sagnac interferometer with Fabry-Perot arm cavities has precisely the same performance, for the same circulating light power, as the Michelson speed-meter interferometer recently invented and studied by Purdue and the author. The influence of optical losses is not studied, but it is plausible that they be fairly unimportant for the Sagnac interferometer, as for other speed meters. With squeezed vacuum (squeeze factor e-2R=0.1) injected into its dark port, the recycled Sagnac interferometer can beat the SQL by a factor (10)≃3 over the frequency band 10 Hz≲f≲150 Hz using the same circulating power Ic˜820 kW as is to be used by the (quantum limited) second-generation Advanced LIGO interferometers—if other noise sources are made sufficiently small. It is concluded that the Sagnac optical configuration, with signal recycling and squeezed-vacuum injection, is an attractive candidate for third-generation interferometric gravitational-wave detectors (LIGO-III and EURO).

  11. GARUSO - Version 1.0. Uncertainty model for multipath ultrasonic transit time gas flow meters

    Energy Technology Data Exchange (ETDEWEB)

    Lunde, Per; Froeysa, Kjell-Eivind; Vestrheim, Magne

    1997-09-01

    This report describes an uncertainty model for ultrasonic transit time gas flow meters configured with parallel chords, and a PC program, GARUSO Version 1.0, implemented for calculation of the meter`s relative expanded uncertainty. The program, which is based on the theoretical uncertainty model, is used to carry out a simplified and limited uncertainty analysis for a 12`` 4-path meter, where examples of input and output uncertainties are given. The model predicts a relative expanded uncertainty for the meter at a level which further justifies today`s increasing tendency to use this type of instruments for fiscal metering of natural gas. 52 refs., 15 figs., 11 tabs.

  12. Five training sessions improves 3000 meter running performance.

    Science.gov (United States)

    Riiser, A; Ripe, S; Aadland, E

    2015-12-01

    The primary aim of the present study was to evaluate the effect of two weeks of endurance training on 3000-meter running performance. Secondary we wanted to assess the relationship between baseline running performance and change in running performance over the intervention period. We assigned 36 military recruits to a training group (N.=28) and a control group. The training group was randomly allocated to one of three sub-groups: 1) a 3000 meter group (test race); 2) a 4x4-minutes high-intensity interval group; 3) a continuous training group. The training group exercised five times over a two-week period. The training group improved its 3000 meter running performance with 50 seconds (6%) compared to the control group (P=0.003). Moreover, all sub-groups improved their performance by 37 to 73 seconds (4-8%) compared to the control group (Ptraining group. We conclude that five endurance training sessions improved 3000 meter running performance and the slowest runners achieved the greatest improvement in running performance.

  13. Development of PIC-based digital survey meter

    International Nuclear Information System (INIS)

    Nor Arymaswati Abdullah; Nur Aira Abdul Rahman; Mohd Ashhar Khalid; Taiman Kadni; Glam Hadzir Patai Mohamad; Abd Aziz Mhd Ramli; Chong Foh Yong

    2006-01-01

    The need of radiation monitoring and monitoring of radioactive contamination in the workplace is very important especially when x-ray machines, linear accelerators, electron beam machines and radioactive sources are present. The appropriate use of radiation detector is significant in order to maintain a radiation and contamination free workplace. This paper reports on the development of a prototype of PIC-based digital survey meter. This prototype of digital survey meter is a hand held instrument for general-purpose radiation monitoring and surface contamination meter. Generally, the device is able to detect some or all of the three major types of ionizing radiation, namely alpha, beta and gamma. It uses a Geiger-Muller tube as a radiation detector, which converts gamma radiation quanta to electric pulses and further processed by the electronic devices. The development involved the design of the controller, counter and high voltage circuit. All these circuit are assembled and enclosed in a plastic casing together with a GM detector and LCD display to form a prototype survey meter. The number of counts of the pulses detected by the survey meter varies due to the random nature of radioactivity. By averaging the reading over a time-period, more accurate and stable reading is achieved. To test the accuracy and the linearity of the design, the prototype was calibrated using standard procedure at the Secondary Standard Dosimetry Laboratory (SSDL) in MINT. (Author)

  14. Design and Implementation of Enhanced Smart Energy Metering System

    Directory of Open Access Journals (Sweden)

    Oday A.L.A Ridha

    2017-03-01

    Full Text Available In this work, the design and implementation of a smart energy metering system has been developed. This system consists of two parts: billing center and a set of distributed smart energy meters. The function of smart energy meter is measuring and calculating the cost of consumed energy according to a multi-tariff scheme. This can be effectively solving the problem of stressing the electrical grid and rising consumer awareness. Moreover, smart energy meter decreases technical losses by improving power factor. The function of the billing center is to issue a consumer bill and contributes in locating the irregularities on the electrical grid (non-technical losses. Moreover, it sends the switch off command in case of the consumer bill is not paid. For implementation of smart energy meter, the microcontroller (PIC 18F45K22 is used. For communication between billing center and smart energy meters, ZigBee technology is adopted. The necessary program for smart energy meter is written in MicroC PRO, while the program for billing center is written in visual C#.

  15. Development of the liquid level meters for the PandaX dark matter detector

    International Nuclear Information System (INIS)

    Hu Jie; Gong Haowei; Lin Qing; Ni Kaixuan; Wei Yuehuan; Xiao Mengjiao; Xiao Xiang; Zhao Li; Tan Andi

    2014-01-01

    The two-phase xenon detector is at the frontier of dark matter direct search. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level needs to be monitored and controlled in sub-millimeter precision. In this paper, we present a detailed design and study of two kinds of level meters for the PandaX dark matter detector. The long level meter is used to monitor the overall liquid level while short level meters are used to monitor the inclination of the detector. These level meters are cylindrical capacitors that are custom-made from two concentric metal tubes. Their capacitance values are read out by a universal transducer interface chip and are recorded by the PandaX slow control system. We present the developments that lead to level meters with long-term stability and sub-millimeter precision. Fluctuations (standard deviations) of less than 0.02 mm for the short level meters and less than 0.2 mm for the long level meter were achieved during a few days of test operation. (authors)

  16. Comprehensive evaluation of the Berthold LB1200 survey meter

    International Nuclear Information System (INIS)

    Davis, M.W.

    1986-05-01

    The performance of two Berthod LB1200 survey meters was evaluated under the influence of a range of beta and photon radiation energies and environmental conditions likely to be encountered in the field. The survey meters responded satisfactorily to the range of beta particle and photon radiation energies emitted by most radioisotopes commonly used in Canada. The survey meters performed acceptably under most of the environmental conditions tested here with the exception of radiofrequency interference and electrostatic charge

  17. User's guide for survey-meter- and film-badge-dosimetry data bases

    International Nuclear Information System (INIS)

    Phillips, W.G.; Sherman, S.; Young, R.

    1981-05-01

    This manual describes the data storage and retrieval system designed by Environmental Monitoring Systems Laboratory Las Vegas (EMSL-LV) for radiation exposure data recorded in offsite areas during and after nuclear weapons tests conducted at the Nevada Test Site in the 1950's and early 1960's. Referred to hereinafter as the EMSL-LV system, this system contains two distinct subsets of offsite radiological measurements collected during early nuclear atmospheric tests at the Nevada Test Site. The purpose of the manual is to present the methods for using the EMSL-LV system to examine all or any portion of either data subset. The two distinct subsets which comprise the EMSL-LV system are survey meter data and film badge dosimetry data. The survey meter data consist of readings obtained from portable radiation monitoring instruments used around the Nevada Test Site during the 1950's and early 1960's to measure radiation exposure rates resulting from the nuclear testing program. The dosimetry data consist of measurements of integrated radiation exposure made with film badge type dosimeters in areas surrounding the Nevada Test Site

  18. Aerodynamic study of a blade with sine variation of chord length along the height for Darrieus wind turbine

    Science.gov (United States)

    Crunteanu, D. E.; Constantinescu, S. G.; Niculescu, M. L.

    2013-10-01

    The wind energy is deemed as one of the most durable energetic variants of the future because the wind resources are immense. Furthermore, one predicts that the small wind turbines will play a vital role in the urban environment. Unfortunately, the complexity and the price of pitch regulated small horizontal-axis wind turbines represent ones of the main obstacles to widespread the use in populated zones. In contrast to these wind turbines, the Darrieus wind turbines are simpler and their price is lower. Unfortunately, their blades run at high variations of angles of attack, in stall and post-stall regimes, which can induce significant vibrations, fatigue and even the wind turbine failure. For this reason, the present paper deals with a blade with sine variation of chord length along the height because it has better behavior in stall and post-stall regimes than the classic blade with constant chord length.

  19. Conducted interference on smart meters

    NARCIS (Netherlands)

    Keyer, Cornelis H.A.; Leferink, Frank

    2017-01-01

    The increasing conducted interference caused by modern electronic equipment is causing more problems for electronic, or static, energy meters. These meters are called smart meters when equipped with a communication link, and are replacing the conventional electromechanical meters. It is known that

  20. Radiofrequency fields associated with the Itron smart meter.

    Science.gov (United States)

    Tell, R A; Sias, G G; Vazquez, A; Sahl, J; Turman, J P; Kavet, R I; Mezei, G

    2012-08-01

    This study examined radiofrequency (RF) emissions from smart electric power meters deployed in two service territories in California for the purpose of evaluating potential human exposure. These meters included transmitters operating in a local area mesh network (RF LAN, ∼250 mW); a cell relay, which uses a wireless wide area network (WWAN, ∼1 W); and a transmitter serving a home area network (HAN, ∼70 mW). In all instances, RF fields were found to comply by a wide margin with the RF exposure limits established by the US Federal Communications Commission. The study included specialised measurement techniques and reported the spatial distribution of the fields near the meters and their duty cycles (typically smart meters as deployed. However, the results are restricted to a single manufacturer's emitters.

  1. An alternative arrangement of metered dosing fluid using centrifugal pump

    Science.gov (United States)

    Islam, Md. Arafat; Ehsan, Md.

    2017-06-01

    Positive displacement dosing pumps are extensively used in various types of process industries. They are widely used for metering small flow rates of a dosing fluid into a main flow. High head and low controllable flow rates make these pumps suitable for industrial flow metering applications. However their pulsating flow is not very suitable for proper mixing of fluids and they are relatively more expensive to buy and maintain. Considering such problems, alternative techniques to control the fluid flow from a low cost centrifugal pump is practiced. These include - throttling, variable speed drive, impeller geometry control and bypass control. Variable speed drive and impeller geometry control are comparatively costly and the flow control by throttling is not an energy efficient process. In this study an arrangement of metered dosing flow was developed using a typical low cost centrifugal pump using bypass flow technique. Using bypass flow control technique a wide range of metered dosing flows under a range of heads were attained using fixed pump geometry and drive speed. The bulk flow returning from the system into the main tank ensures better mixing which may eliminate the need of separate agitators. Comparative performance study was made between the bypass flow control arrangement of centrifugal pump and a diaphragm type dosing pump. Similar heads and flow rates were attainable using the bypass control system compared to the diaphragm dosing pump, but using relatively more energy. Geometrical optimization of the centrifugal pump impeller was further carried out to make the bypass flow arrangement more energy efficient. Although both the systems run at low overall efficiencies but the capital cost could be reduced by about 87% compared to the dosing pump. The savings in capital investment and lower maintenance cost very significantly exceeds the relatively higher energy cost of the bypass system. This technique can be used as a cost effective solution for

  2. Glucose meters: evaluation of the new formulation measuring strips from Roche (Accu-Chek) and Abbott (MediSense).

    Science.gov (United States)

    Dimeski, G; Jones, B W; Tilley, V; Greenslade, M N; Russell, A W

    2010-07-01

    Both Roche and Abbott have released new glucose meter strips. They supply the entire Australian hospital market. The present study compared the performance of the new strips utilizing various specimen types (capillary, venous lithium heparin whole blood, venous lithium heparin plasma and serum) and evaluated how well they comply with the International Standards Organization (ISO) 15197 criteria. The study included imprecision, patient comparison and interference studies. Participants with and without diabetes were recruited to evaluate the performance of various specimen types against the Beckman DxC800 glucose method. The strips were tested for different interferences: galactose, maltose, lactose, Icodextrin, Intragam, paracetamol, sodium, ascorbic acid, variable strip storage temperature, haematocrit, haemolysis and lipaemia. The imprecision of the two strips was approximately 5% or less, except for the Abbott strip at very low values (1.4 mmol/L), approximately 7%. In total, 78% and 84%, respectively, of the results from the finger prick capillary specimens with the Roche (Accu-Chek Performa meter) and Abbott (Optium Xceed meter) strips, not 95% or greater as recommended by the ISO guideline, were within the recommended limits compared with reference plasma estimation on laboratory analysers. Galactose, ascorbic acid, haematocrit and sodium on the Roche and ascorbic acid and haematocrit on the Abbott strip continue to interfere to a variable degree with the glucose measurement. Analytically small differences exist between the glucose meter strips. The most significant analytical difference with the strips was at low glucose levels when compared with laboratory analyses and this may be of clinical importance. The impact of some of the interferences is variable between the two strips. Individuals, health-care professionals and health-care institutions should consider these data when selecting glucose meters for the management of people with diabetes mellitus.

  3. Net metering study of switching effects on electromechanical meters[Report prepared for the Measurement Canada Electricity Net Metering Project

    Energy Technology Data Exchange (ETDEWEB)

    Van Overberghe, L. [Measurement Canada, London, ON (Canada)

    2006-03-03

    The feasibility of introducing net metering in the electricity sector was evaluated with particular reference to a project administered by Measurement Canada and Electro-Federation Canada (MicroPower Connect) in collaboration with Natural Resources Canada. The objective of the Measurement Canada Electricity Net Metering Project is to identify and eliminate the barriers introduced by the Electricity and Gas Inspection Act regarding the introduction of net metering. The purpose was to design a device that would allow rotation reversal in a residential electromechanical single phase meter. The device should approximate any fluctuations found in a typical net metering system. A series of tests were conducted to understand the influences, on errors, of forward-to-reverse and reverse-to-forward transitions, specifically to find evidence of error migration and mechanical stress. The project was designed to find and measure the effects of forward reverse switching on an electromechanical meter resulting from a change in energy flow. Twenty metres were calibrated in the forward direction in series from light load to high load. Power factor was not adjustable. Test points were then applied in both the forward and reverse directions. The exercise yielded individual errors which were aggregated to show average found errors after 3,000 transitions. Small shifts in errors were apparent and there was no evidence to support a disk flutter theory. refs., tabs., figs.

  4. Comparing the NIOSH Method 5040 to a Diesel Particulate Matter Meter for Elemental Carbon

    Science.gov (United States)

    Ayers, David Matthew

    Introduction: The sampling of elemental carbon has been associated with monitoring exposures in the trucking and mining industries. Recently, in the field of engineered nanomaterials, single wall and muti-wall carbon nanotubes (MWCNTs) are being produced in ever increasing quantities. The only approved atmospheric sampling for multi-wall carbon nanotubes in NIOSH Method 5040. These results are accurate but can take up to 30 days for sample results to be received. Objectives: Compare the results of elemental carbon sampling from the NIOSH Method 5040 to a Diesel Particulate Matter (DPM) Meter. Methods: MWCNTs were transferred and weighed between several trays placed on a scale. The NIOSH Method 5040 and DPM sampling train was hung 6 inches above the receiving tray. The transferring and weighing of the MWCNTs created an aerosol containing elemental carbon. Twenty-one total samples using both meters type were collected. Results: The assumptions for a Two-Way ANOVA were violated therefore, Mann-Whitney U Tests and a Kruskal-Wallis Test were performed. The hypotheses for both research questions were rejected. There was a significant difference in the EC concentrations obtained by the NIOSH Method 5040 and the DPM meter. There were also significant differences in elemental carbon level concentrations when sampled using a DPM meter versus a sampling pump based upon the three concentration levels (low, medium and high). Conclusions: The differences in the EC concentrations were statistically significant therefore, the two methods (NIOSH Method 5040 and DPM) are not the same. The NIOSH Method 5040 should continue to be the only authorized method of establishing an EC concentration for MWCNTs until a MWCNT specific method or an instantaneous meter is invented.

  5. Smart Meter Data Analytics: Systems, Algorithms and Benchmarking

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Golab, Lukasz; Golab, Wojciech

    2016-01-01

    the proposed benchmark using five representative platforms: a traditional numeric computing platform (Matlab), a relational DBMS with a built-in machine learning toolkit (PostgreSQL/MADlib), a main-memory column store (“System C”), and two distributed data processing platforms (Hive and Spark/Spark Streaming......Smart electricity meters have been replacing conventional meters worldwide, enabling automated collection of fine-grained (e.g., every 15 minutes or hourly) consumption data. A variety of smart meter analytics algorithms and applications have been proposed, mainly in the smart grid literature......-line feature extraction and model building as well a framework for on-line anomaly detection that we propose. Second, since obtaining real smart meter data is difficult due to privacy issues, we present an algorithm for generating large realistic data sets from a small seed of real data. Third, we implement...

  6. Evaluation of Blood Glucose Meter Efficacy in an Antenatal Diabetes Clinic.

    Science.gov (United States)

    McGrath, Rachel T; Donnelly, Vanessa C; Glastras, Sarah J; Preda, Veronica A; Sheriff, Nisa; Ward, Peter; Hocking, Samantha L; Fulcher, Gregory R

    2016-02-01

    The optimal treatment of diabetes in pregnancy requires accurate measurement of blood glucose levels, in order to minimize adverse outcomes for both mother and neonate. Self-monitoring of blood glucose is routinely used to measure glycemic control and to assess whether treatment targets are being met; however, the accuracy of blood glucose meters in pregnancy is unclear. Pregnant women with gestational, type 1, or type 2 diabetes mellitus were eligible to participate. Nonfasting capillary blood glucose levels were measured in duplicate using the BGStar(®) (Sanofi, Sydney, Australia) and FreeStyle Lite(®) (Abbott, Sydney) blood glucose meters. Venous blood samples were collected and analyzed for plasma glucose, hematocrit, and glycated hemoglobin. Capillary blood glucose was compared with plasma glucose and further assessed according to International Organization for Standardization (ISO) 15197:2013 standards. One hundred ten women were recruited, providing 96 samples suitable for analysis. The mean ± SD laboratory plasma glucose level was 4.6 ± 1.4 mmol/L; the BGStar and FreeStyle Lite capillary blood glucose values were 5.3 ± 1.4 mmol/L and 5.0 ± 1.3 mmol/L, respectively. Both meters showed a positive bias (0.42 mmol/L for the FreeStyle Lite and 0.65 mmol/L for the BGStar). Furthermore, neither meter fulfilled the ISO 15197:2013 standards, and there was a nonsignificant improvement in meter performance at blood glucose levels of ≤4.2 mmol/L. Hematocrit did not affect the results of either blood glucose meter. Clarke Error Grid analysis demonstrated that approximately 70% of the results of both meters would lead to appropriate clinical action. The BGStar and FreeStyle Lite blood glucose meters did not meet ISO 15197:2013 recommendations for blood glucose monitoring systems when assessed in a population of women with diabetes in pregnancy. Clinicians should consider this difference in blood glucose readings when making diabetes

  7. Steady and Unsteady Analysis of NACA 0018 Airfoil in Vertical-Axis Wind Turbine

    DEFF Research Database (Denmark)

    Rogowski, Krzysztof; Hansen, Martin Otto Laver; Maronski, Ryszard

    2018-01-01

    Numerical results are presented for aerodynamic unsteady and steady airfoil characteristtcs of the NACA 0018 airfoil of a two-dimensional vertical-axis wind turbine. A geometrical model of the Darrieus-type wind turbine and the rotor operating parameters used for nurnerieal simulation are taken...

  8. A new kind high-reliability digital reactivity meter

    International Nuclear Information System (INIS)

    Shen Feng; Jiang Zongbing

    2001-01-01

    The paper introduces a new kind of high-reliability Digital Reactivity Meter developed by the DRM developing group in designing department of Nuclear Power Institute of China. The meter has two independent measure channels, which can be set as either master-slave structure or working independently. This structure will ensure that the meter can continually fulfill its online measure task under the condition of single failure with it. It provides a solution for the conflict between nuclear station's extreme demand in DRM's reliability and instability of computer's business software platform. The instrument reaches both advance and reliability by covering a lot of kinds of complex functions in data process and display

  9. The development of two-phase flow instrumentation at PNC O-arai Engineering Center

    International Nuclear Information System (INIS)

    Obata, T.; Kobori, T.; Hayamizu, Y.

    1975-10-01

    This paper reviews development works on the two-phase flow instrumentation carried out at PNC Oarai Engineering Center for FUGEN safety test. The paper describes heater surface temperature measurement, four types of void meters and two steam quality meters. (auth.)

  10. Diseño de un aerogenerador tipo H-Darrieus y estudio de la influencia del ángulo de pitch, mediante mecánica de fluidos computacional

    OpenAIRE

    Río Sánchez, Saúl del

    2017-01-01

    Este trabajo es un estudio de diseño, mediante CFD, de un aerogenerador de eje vertical de tipo H-Darrieus de tres álabes. Se ha realizado el diseño general, viendo la sensibilidad a la malla y comparando los resultados con otros de la bibliografía, se han representado las curvas características y el patrón de flujo para conocer el comportamiento de la turbina. Aparte del diseño, también se ha realizado un análisis de cómo afectan los cambios realizados en la configuración d...

  11. Hydraulic Darrieus turbines efficiency for free fluid flow conditions versus power farms conditions

    Energy Technology Data Exchange (ETDEWEB)

    Antheaume, Sylvain [Electricite de France, Recherche et Developpement, Laboratoire National d' Hydraulique et Environnement, 6 Quai Watier, 78400 Chatou (France); Maitre, Thierry; Achard, Jean-Luc [Laboratoire des Ecoulements Geophysiques et Industriels, BP 53, 38041 Grenoble (France)

    2008-10-15

    The present study deals with the efficiency of cross flow water current turbine for free stream conditions versus power farm conditions. In the first part, a single turbine for free fluid flow conditions is considered. The simulations are carried out with a new in house code which couples a Navier-Stokes computation of the outer flow field with a description of the inner flow field around the turbine. The latter is based on experimental results of a Darrieus wind turbine in an unbounded domain. This code is applied for the description of a hydraulic turbine. In the second part, the interest of piling up several turbines on the same axis of rotation to make a tower is investigated. Not only is it profitable because only one alternator is needed but the simulations demonstrate the advantage of the tower configuration for the efficiency. The tower is then inserted into a cluster of several lined up towers which makes a barge. Simulations show that the average barge efficiency rises as the distance between towers is decreased and as the number of towers is increased within the row. Thereby, the efficiency of a single isolated turbine is greatly increased when set both into a tower and into a cluster of several towers corresponding to possible power farm arrangements. (author)

  12. Ultrasonic flow-meter test in sodium

    International Nuclear Information System (INIS)

    Ishii, Y.; Uno, O.; Kamei, M.

    1978-01-01

    As a part of the R and D programme for the prototype fast breeder reactor MONJU, an ultrasonic flow-meter (USFM) test is being carried out in sodium in the O-Arai Engineering Center of PNC. Prior to the present test, an in-water test was done at the manufacturer's as a preliminary investigation. The results reported here are the results up to the present. Calibration tests using the actual fluid were conducted on a 12-inch ultrasonic flow-meter with guide rods fabricated for sodium flow measurement. The test conditions in sodium were a temperature of 200 approximately 400 0 C and flow-rates of 0 approximately 6m/s. The main results are: (1) The linearity of output signal was good and accuracy was within 1%; (2) The alternating type of the USFM was much better than the fixed type in temperature change; (3) 2MHz of transducer frequency was better than 3MHz in sodium; (4) The S/N ratio of the ultrasonic signal and the length/diameter effect in a wide range in sodium surpassed the in-water test. (author)

  13. Relative accuracy of the BD Logic and FreeStyle blood glucose meters.

    Science.gov (United States)

    2007-04-01

    The BD Logic((R)) (Becton, Dickinson and Co., Franklin Lakes, NJ) and FreeStyle((R)) (Abbott Diabetes Care, Alameda, CA) meters are used to transmit data directly to insulin pumps for calculation of insulin doses and to calibrate continuous glucose sensors as well as to monitor blood glucose levels. The accuracy of the two meters was evaluated in two inpatient studies conducted by the Diabetes Research in Children Network (DirecNet). In both studies, meter glucose measurements made with either venous or capillary blood were compared with reference glucose measurements made by the DirecNet Central Laboratory at the University of Minnesota using a hexokinase enzymatic method. The BD Logic tended to read lower than the laboratory reference regardless of whether venous (median difference = -9 mg/dL) or capillary blood (median difference = -7 mg/dL) was used. This resulted in lower accuracy of the BD Logic compared with the FreeStyle meter based on the median relative absolute difference (RAD) for both venous blood (median RAD, 9% vs. 5%, P blood (median RAD, 11% vs. 6%, P = 0.008). The greatest discrepancy in the performance of the two meters was at higher reference glucose values. Accuracy was not significantly different when the reference was < or = 70 mg/dL. The BD Logic meter is less accurate than the FreeStyle meter.

  14. Radiofrequency fields associated with the Itron smart meter

    International Nuclear Information System (INIS)

    Tell, R. A.; Sias, G. G.; Vazquez, A.; Sahl, J.; Turman, J. P.; Kavet, R. I.; Mezei, G.

    2008-01-01

    This study examined radiofrequency (RF) emissions from smart electric power meters deployed in two service territories in California for the purpose of evaluating potential human exposure. These meters included transmitters operating in a local area mesh network (RF LAN, ∼250 mW); a cell relay, which uses a wireless wide area network (WWAN, ∼1 W); and a transmitter serving a home area network (HAN, ∼70 mW). In all instances, RF fields were found to comply by a wide margin with the RF exposure limits established by the US Federal Communications Commission. The study included specialised measurement techniques and reported the spatial distribution of the fields near the meters and their duty cycles (typically <1 %) whose value is crucial to assessing time-averaged exposure levels. This study is the first to characterise smart meters as deployed. However, the results are restricted to a single manufacturer's emitters. (authors)

  15. Fundamental principles of rotary displacement meters

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, J. [Schlumberger Industries, Owenton, KY (United States)

    1995-12-01

    The gas meter exists to continually and accurately measure the volume of gas supplied over the complete flow range of the load. In effect the gas meter serves as the {open_quotes}cash register{close_quotes} of the gas industry; its accurate and dependable performance ensures fair dealings for both the supplier and the user. An investment both in and of itself, the gas meter should be chosen as a function of its usefullness both over the short term and the long term. Thus in addition to initial cost, one must take into account various associated factors, costs and benefits, including the following: Design Characteristics Application, suitability, Meter features and options, Operation constraints, Installation, Service and maintenance, Repair and replacement, Life expectancy, Compatibility with complimentary products, Correcting devices, Remote reading capabilities, Data generation and gathering, Upgradeabilty. This paper will look at one positive displacement meter, the Rotary meter, and address the fundamentals principals of the technology as well as looking at some of the benefits derived from its application. Rotary positive displacement meters were introduced at the end of last century. Used primarily for metering transmission sized loads, the meters` measuring capabilities have extended to cover nearly all areas of distribution with exception of domestic applications. Rotary meters are available in rated capacities from 800 cfh to 102,000 cfh and operating pressures from 175 PSIG to 1440 PSIG. The use of rotary meters on load ranges in the 800 to 10,000 cfh category has increased and is replacing the use of diaphragm meters because of the smaller relative size of rotaries, and improvements in rangeabilities in the last few years. Turbine meters are usually the meter of choice on loads over 16,000 cfh unless a meter with high rangeability is required because of varying load characteristics, in which case a large foot mounted rotary might still be selected.

  16. OOK power model based dynamic error testing for smart electricity meter

    International Nuclear Information System (INIS)

    Wang, Xuewei; Chen, Jingxia; Jia, Xiaolu; Zhu, Meng; Yuan, Ruiming; Jiang, Zhenyu

    2017-01-01

    This paper formulates the dynamic error testing problem for a smart meter, with consideration and investigation of both the testing signal and the dynamic error testing method. To solve the dynamic error testing problems, the paper establishes an on-off-keying (OOK) testing dynamic current model and an OOK testing dynamic load energy (TDLE) model. Then two types of TDLE sequences and three modes of OOK testing dynamic power are proposed. In addition, a novel algorithm, which helps to solve the problem of dynamic electric energy measurement’s traceability, is derived for dynamic errors. Based on the above researches, OOK TDLE sequence generation equipment is developed and a dynamic error testing system is constructed. Using the testing system, five kinds of meters were tested in the three dynamic power modes. The test results show that the dynamic error is closely related to dynamic power mode and the measurement uncertainty is 0.38%. (paper)

  17. OOK power model based dynamic error testing for smart electricity meter

    Science.gov (United States)

    Wang, Xuewei; Chen, Jingxia; Yuan, Ruiming; Jia, Xiaolu; Zhu, Meng; Jiang, Zhenyu

    2017-02-01

    This paper formulates the dynamic error testing problem for a smart meter, with consideration and investigation of both the testing signal and the dynamic error testing method. To solve the dynamic error testing problems, the paper establishes an on-off-keying (OOK) testing dynamic current model and an OOK testing dynamic load energy (TDLE) model. Then two types of TDLE sequences and three modes of OOK testing dynamic power are proposed. In addition, a novel algorithm, which helps to solve the problem of dynamic electric energy measurement’s traceability, is derived for dynamic errors. Based on the above researches, OOK TDLE sequence generation equipment is developed and a dynamic error testing system is constructed. Using the testing system, five kinds of meters were tested in the three dynamic power modes. The test results show that the dynamic error is closely related to dynamic power mode and the measurement uncertainty is 0.38%.

  18. Digital temperature meter

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S

    1982-01-01

    Digital temperature meter for precise temperature measurements is presented. Its parts such as thermostat, voltage-frequency converter and digital frequency meter are described. Its technical parameters such as temperature range 50degC-700degC, measurement precision 1degC, measurement error +-1degC are given. (A.S.).

  19. Ultrasonic flow meter

    NARCIS (Netherlands)

    Lötters, Joost Conrad; Snijders, G.J.; Volker, A.W.F.

    2014-01-01

    The invention relates to an ultrasonic flow meter comprising a flow tube for the fluid whose flow rate is to be determined. The flow meter comprises a transmitting element for emitting ultrasonic waves, which is provided on the outer jacket of the flow tube. A receiving element, which is provided on

  20. Federal Building Metering Guidance (per 42 U.S.C. 8253(e), Metering of Energy Use)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-11-01

    Guidance defines which federal buildings are appropriate to meter, provides metering prioritization recommendations for agencies with limited resources, and discusses the requirement for agencies to submit metering implementation plans to the U.S. Department of Energy.

  1. Simple, inexpensive computerized rodent activity meters.

    Science.gov (United States)

    Horton, R M; Karachunski, P I; Kellermann, S A; Conti-Fine, B M

    1995-10-01

    We describe two approaches for using obsolescent computers, either an IBM PC XT or an Apple Macintosh Plus, to accurately quantify spontaneous rodent activity, as revealed by continuous monitoring of the spontaneous usage of running activity wheels. Because such computers can commonly be obtained at little or no expense, and other commonly available materials and inexpensive parts can be used, these meters can be built quite economically. Construction of these meters requires no specialized electronics expertise, and their software requirements are simple. The computer interfaces are potentially of general interest, as they could also be used for monitoring a variety of events in a research setting.

  2. Smart meter status report from Toronto

    International Nuclear Information System (INIS)

    O'Brien, D.

    2006-01-01

    An update of Toronto Hydro's smart metering program was presented. Electricity demand is expected to keep increasing, and there is presently insufficient generation to match supply needs in Ontario. The smart metering program was introduced to aid in the Ontario government's energy conservation strategy, as well as to address peak supply problems that have led to power outages. It is expected that the smart metering program will reduce provincial peak supply by 5 per cent, as the meters support both time-of-use rates and critical peak pricing. Over 800,000 smart meters will be supplied to customers by 2007, and all 4.3 million homes in Toronto will have a smart meter by 2010. In order to meet targets for 2010, the utility will continue to install more 15,000 meters each month for the next 4 years. While the Ontario government has planned and coordinated the rollout and developed smart metering specifications and standards, Toronto Hydro is responsible for the purchase, installation, operation and maintenance of the meters. Advance testing of each meter is needed to ensure billing accuracy, and customer education on meter use is also. The complexity of the metering program has led the utility to establish a rigid project management process. Customer education pilot program are currently being conducted. Experience gained during the earlier phases of the program have enabled the utility to select appropriate metering systems based on density, topography and physical conditions. Project expenditures have been within budget due to improved project estimating and planning. The metering program has been conducted in tandem with the utility's peakSAVER program, a residential and small commercial load control program that has been successful in reducing summer peak demand by cycling air conditioners without causing discomfort. It was concluded that the utility will continue with its mass deployment of smart meters, and is currently preparing its call center to handled

  3. Instrument evaluation no. 13. Nuclear enterprises portable meter type PDR

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report deals with the evaluation of Nuclear Enterprises Portable Dose Rate Meter Type PDR 2

  4. Streamlining Smart Meter Data Analytics

    OpenAIRE

    Liu, Xiufeng; Nielsen, Per Sieverts

    2015-01-01

    Today smart meters are increasingly used in worldwide. Smart meters are the advanced meters capable of measuring customer energy consumption at a fine-grained time interval, e.g., every 15 minutes. The data are very sizable, and might be from different sources, along with the other social-economic metrics such as the geographic information of meters, the information about users and their property, geographic location and others, which make the data management very complex. On the other hand, ...

  5. Determination for energy response and directionality of neutron survey meters

    International Nuclear Information System (INIS)

    Chen Changmao; Liu Jinhua; Xie Jianlun; Su Jingling

    1992-01-01

    The energy response and directionality of neutron survey meter type MK7 and 2202D are determined. The reactor thermal column beam, reactor filtered beams (6 eV, 24.4 keV and 144 keV), 226 Ra-Be, 241 Am-Be, 252 Cf and its moderated sources are used for the measurement. The results shows: the survey meters are influenced obviously by the direction; the response of middle-energy region is large, the energy response of 2202D is better than MK7

  6. Technique of Hurdle Clearing in 400 Meters Hurdles (Study Review)

    OpenAIRE

    Jakoubek, Jiří

    2017-01-01

    Title: Technique of Hurdle Clearing in 400 Meters Hurdles (Study Review) Authors: Jiří Jakoubek Supervisor: PhDr. Aleš Kaplan, Ph.D. Aims: The aim of this thesis is to describe technique of hurdle clearing in 400 meters hurdle race using study review and to examine this technique at particular athlete during training and racing sessions in 400 meters hurdles race. Methods: Technique was compared and examined at young athlete. Two kinograms were used for analysis, one from training and one fro...

  7. Instrument evaluation no. 5. Wallac OY universal radiation survey meter type RD-8

    International Nuclear Information System (INIS)

    White, D.F.; Blundell, D.R.; Callowhill, K.; Iles, W.J.

    1976-05-01

    The Wallace RD-8 is a portable, battery-operated survey meter covering an exposure rate range from 0.01 mR/h to 300 R/h. The instrument was designed specifically for military and civil defence applications and is accordingly of particularly rugged construction and claimed to be both waterproof and shockproof. This instrument is unusual in that it has two internally mounted radiation detectors. An end-window GM tube is used to cover the range from 0.01 to 300 mR/h, and a GM tube covers the range from 0.01 to 300 R/h. Both tubes have energy compensation sheaths for the measurement of photon radiation in the forward direction. Only the first tube permits the measurement of β-radiation. The information is given under the following headings; Facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; summary of performance; calibration procedure; conclusions. (U.K.)

  8. Comparison of broad band time series recorded parallel by FGI type interferometric water level and Lippmann type pendulum tilt meters at Conrad observatory, Austria

    Science.gov (United States)

    Ruotsalainen, Hannu; Papp, Gabor; Leonhardt, Roman; Ban, Dora; Szücs, Eszter; Benedek, Judith

    2016-04-01

    The Finnish Geodetic Institute (FGI) the progenitor of Finnish Geospatial Research Institute of NLS designed and built a 5.5m long prototype of interferometric water level tiltmeter (iWT) in early 2014. Geodetic and Geophysical Institute (GGI), Sopron, Hungary bought the instrument and started tilt measurement in August 2014 at the Conrad observatory (COBS), Austria to monitor geodynamical phenomena like microseisms, free oscillations of the Earth, earth tides, mass loading effects and crustal deformations in cooperation with Austrian Central Institute for Meteorology and Geodynamics (ZAMG) and the FGI. On the July 16 2015 a Lippmann-type 2D tilt sensor (LTS) was also installed by GGI on the 6 m long pier where iWT was set up previously. This situation opens a possibility to do broad band (from secular to seismic variations up to 15 Hz) geophysical signal analysis comparing the responses of long (several meters) and short (a few decimeters) base instruments implementing different physical principles (relative height change of a level surface and inclination change of the plumb line). The characteristics of the sensors are studied by the evaluation of the spectra of recorded signals dominated by microseisms. The iWT has internal interferometric calibration and it can be compared to Lippmanns tilt meter one. Both instruments show good long term ( > 1 day) stability when earth tides and ocean and air mass loading tilts are modelled.

  9. Simple meters get smart? Cost benefit analysis of smart metering infrastructure

    International Nuclear Information System (INIS)

    Van Gerwen, R.J.F.; Jaarsma, S.A.; Koenis, F.T.C.

    2005-08-01

    The Dutch Ministry of Economic Affairs requested a cost-benefit analysis of the large scale introduction of a smart meter infrastructure for gas and electricity consumption by small consumers. The questions asked in the study need to be answered in order to enable a well-founded evaluation of the implementation of smart meters. [mk] [nl

  10. Metering apparatus and tariffs for electricity supply

    International Nuclear Information System (INIS)

    1990-01-01

    Conference papers presented cover system economies and tariff structure with papers on pricing of electricity and new metering technologies. Other topics reviewed include metering apparatus design, electronic metering apparatus and solid phase metering technology. Meter data retrieval, bulk supply metering, test equipment and maintenance, and legal requirements and standards are discussed. (author)

  11. Metering management at the plutonium research and development facilities

    International Nuclear Information System (INIS)

    Hirata, Masaru; Miyamoto, Fujio; Kurosawa, Makoto; Abe, Jiro; Sakai, Haruyuki; Suzuki, Tsuneo.

    1996-01-01

    Nuclear fuel research laboratory of the Oarai Research Laboratory of the Japan Atomic Energy Research Institute is an R and D facility to treat with plutonium and processes various and versatile type samples in chemical and physical form for use of various experimental researches even though on much small amount. Furthermore, wasted and plutonium samples are often transported to other KMP and MBA such as radioactive waste management facility, nuclear reactor facility and so forth. As this facility is a place to treat plutonium important on the safeguards, it is a facility necessary for detection and allowance actions and for detail managements on the metering management data to report to government and IAEA in each small amount sample and different configuration. In this paper, metering management of internationally regulated matters and metering management system using a work station newly produced in such small scale facility were introduced. (G.K.)

  12. Cross-cultural differences in meter perception.

    Science.gov (United States)

    Kalender, Beste; Trehub, Sandra E; Schellenberg, E Glenn

    2013-03-01

    We examined the influence of incidental exposure to varied metrical patterns from different musical cultures on the perception of complex metrical structures from an unfamiliar musical culture. Adults who were familiar with Western music only (i.e., simple meters) and those who also had limited familiarity with non-Western music were tested on their perception of metrical organization in unfamiliar (Turkish) music with simple and complex meters. Adults who were familiar with Western music detected meter-violating changes in Turkish music with simple meter but not in Turkish music with complex meter. Adults with some exposure to non-Western music that was unmetered or metrically complex detected meter-violating changes in Turkish music with both simple and complex meters, but they performed better on patterns with a simple meter. The implication is that familiarity with varied metrical structures, including those with a non-isochronous tactus, enhances sensitivity to the metrical organization of unfamiliar music.

  13. Multitasking metering enhances generation, transmission operations

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, E.

    2008-11-15

    The Dairyland Power Cooperative (DPC) which operates from La Crosse, Wisconsin has the capacity to generate and transmit 1000 MW of power to 25 member cooperatives and 20 municipalities who serve over 500,000 customers. When DPC was experiencing diminished service within its analog cellular-based data communications system, it was presented with an opportunity to install a new automated telecommunications system that would provide secure collection of meter readings from all of its substations. DPC decided to evaluate an advanced multifunctional digital meter from Schweitzer Engineering Laboratories (SEL). The SEL-734 Revenue Metering System offers complete instantaneous metering functions, including voltages, currents, power, energy and power factor. Other capabilities include predictive demand, time-of-use metering, automatic voltage monitoring, harmonics metering and synchrophasor measurement. From a metering perspective, DPC wanted to perform daily load profiles and interval-by-interval metering of their delivery points for billing purposes. They also wanted to provide real-time monitoring of electricity being delivered for both generation and transmission purposes and to make that information available to a distribution SCADA system for their members. The SEL-734 Revenue Meter was well suited to those needs. The SEL-734 provides very high-accuracy energy metering, load profile data collection, instantaneous power measurements, power quality monitoring, and communicates simultaneously over a modem, serial ports, and wide area networks (WAN). The meter is backed with a ten-year warranty as well as field support engineers. 5 figs.

  14. Smart meter incorporating UWB technology

    NARCIS (Netherlands)

    Khan, T.A.; Khan, A.B.; Babar, M.; Taj, T.A.

    2014-01-01

    Smart Meter is a key element in the evolving concept of Smart Grid, which plays an important role in interaction between the consumer and the supplier. In general, the smart meter is an intelligent digital energy meter that measures the consumption of electrical energy and provides other additional

  15. Good standards for smart meters

    NARCIS (Netherlands)

    Hoenkamp, R.A.; Huitema, G.B.

    2012-01-01

    This paper examines what lessons can be learned from the rollout of smart meters in the Netherlands to improve the European smart meter standardization. This study is based on the case of the Dutch meter rollout which preparations started in 2005 but finally was delayed until 2011 by governmental

  16. RFID-BASED Prepaid Power Meter

    OpenAIRE

    Teymourzadeh, Rozita

    2013-01-01

    An Electric power meter is an important component in electric energy service. In the past, many consumers have complained about reading inaccurate of the electric meter. This research presents the development of an electrical power meter equipped with RFID reader. The RFID reader reads a valid RFID card and activates the power meter so that it can supply electricity. When the credit is about low or before the electricity is auto cut off, an SMS message will be sent to the user’s handphone to ...

  17. Privacy friendly aggregation of smart meter readings, even when meters crash

    NARCIS (Netherlands)

    Hoepman, J.H.

    2017-01-01

    A well studied privacy problem in the area of smart grids is the question of how to aggregate the sum of a set of smart meter readings in a privacy friendly manner, i.e., in such a way that individual meter readings are not revealed to the adversary. Much less well studied is how to deal with

  18. Ramp Metering Influence on Freeway Operational Safety near On-ramp Exits

    Directory of Open Access Journals (Sweden)

    Chiu Liu, PhD, PE, PTOE

    2013-06-01

    Full Text Available Ramp metering has been widely installed in urban areas where congestion on a freeway or an expressway may occur recurrently during weekday peak periods to enhance mainline throughput and reduce system-wide delay. These operational benefits may also help reduce vehicular emissions and improve air quality in urban areas. However, the impact on traffic safety due to ramp metering hasn't been explored in details before. Supported by physical understanding and arguments, we characterize the ramp metering influence on freeway safety by examining vehicular collisions near on-ramp exits within the ramp meter operating hours before and after the activation of the ramp metering. Collisions for a sample of 19 operating ramp meters along several freeways in northern California were collected and organized to show that ramp metering can help reduce freeway collisions at the vicinity of on-ramp exits. It was found that the average reductions on freeway collisions in the vicinity of an on-ramp exit are around 36%. Although most of the reduced collisions belong to the property damage only category, a 36% reduction shows the significant safety benefit of ramp metering. The traffic congestion induced by each collision, especially during peak hours when ramp metering is in operation, could last for an hour or two. Consequently, ramp metering must be contributing to the reduction of non-recurrent congestion in addition to mitigating recurrent congestion, which is better documented. This study strongly supports the implementation of ramp metering in California.

  19. Instrument evaluation no. 9. Mini-instruments dose rate meter type 5 - 1OR

    International Nuclear Information System (INIS)

    Iles, W.J.; Burgess, P.H.; Callowhill, K.

    1977-04-01

    This instrument is a portable, battery powered dose rate meter covering the dose rate range from 0 to 200 mrad h -1 . The instrument is designed to measure X- and γ-radiation dose rates over the energy range from 45 keV to 3 MeV. The radiation detector of the instrument is a GM tube with a specially designed energy compensation sheath. This detector is incorporated in a probe connected to the rate meter by an extensible cable which may be either hand-held or clipped on to the top of the instrument case. All the measurements in this report have been taken with the long axis of the probe normal to the direction of the incident radiation, the orientation recommended by the manufacturer. The information is given under the following headings: facilities and controls; radiation characteristics; electrical characteristics; effect of ambient temperature; mechanical characteristics; summary of performance; conclusions. (U.K.)

  20. Evaluation of the apparent losses caused by water meter under-registration in intermittent water supply.

    Science.gov (United States)

    Criminisi, A; Fontanazza, C M; Freni, G; Loggia, G La

    2009-01-01

    Apparent losses are usually caused by water theft, billing errors, or revenue meter under-registration. While the first two causes are directly related to water utility management and may be reduced by improving company procedures, water meter inaccuracies are considered to be the most significant and hardest to quantify. Water meter errors are amplified in networks subjected to water scarcity, where users adopt private storage tanks to cope with the intermittent water supply. The aim of this paper is to analyse the role of two variables influencing the apparent losses: water meter age and the private storage tank effect on meter performance. The study was carried out in Palermo (Italy). The impact of water meter ageing was evaluated in laboratory by testing 180 revenue meters, ranging from 0 to 45 years in age. The effects of the private water tanks were determined via field monitoring of real users and a mathematical model. This study demonstrates that the impact on apparent losses from the meter starting flow rapidly increases with meter age. Private water tanks, usually fed by a float valve, overstate meter under-registration, producing additional apparent losses between 15% and 40% for the users analysed in this study.

  1. Performance Analysis of Secure and Private Billing Protocols for Smart Metering

    Directory of Open Access Journals (Sweden)

    Tom Eccles

    2017-11-01

    Full Text Available Traditional utility metering is to be replaced by smart metering. Smart metering enables fine-grained utility consumption measurements. These fine-grained measurements raise privacy concerns due to the lifestyle information which can be inferred from the precise time at which utilities were consumed. This paper outlines and compares two privacy-respecting time of use billing protocols for smart metering and investigates their performance on a variety of hardware. These protocols protect the privacy of customers by never transmitting the fine-grained utility readings outside of the customer’s home network. One protocol favors complexity on the trusted smart meter hardware while the other uses homomorphic commitments to offload computation to a third device. Both protocols are designed to operate on top of existing cryptographic secure channel protocols in place on smart meters. Proof of concept software implementations of these protocols have been written and their suitability for real world application to low-performance smart meter hardware is discussed. These protocols may also have application to other privacy conscious aggregation systems, such as electronic voting.

  2. Smart metering design and applications

    CERN Document Server

    Weranga, K S K; Chandima, D P

    2013-01-01

    Taking into account the present day trends and the requirements, this Brief focuses on smart metering of electricity for next generation energy efficiency and conservation. The contents include discussions on the smart metering concepts and existing technologies and systems as well as design and implementation of smart metering schemes together with detailed examples.

  3. A two-phase flow regime map for a MAPLE-type nuclear research reactor fuel channel: Effect of hexagonal finned bundle

    International Nuclear Information System (INIS)

    Harvel, G.D.; Chang, J.S.

    1997-01-01

    A two-phase flow regime map is developed experimentally and theoretically for a vertical hexagonal flow channel with and without a 36-finned rod hexagonal bundle. This type of flow channel is of interest to MAPLE-type nuclear research reactors. The flow regime maps are determined by visual observations and observation of waveforms shown by a capacitance-type void fraction meter. The experimental results show that the inclusion of the finned hexagonal bundle shifts the flow regime transition boundaries toward higher water flow rates. Existing flow regime maps based on pipe flow require slight modifications when applied to the hexagonal flow channel with and without a MAPLE-type finned hexagonal bundle. The proposed theoretical model agrees well with experimental results

  4. Evaluation of energy responses for neutron dose-equivalent meters made in Japan

    International Nuclear Information System (INIS)

    Saegusa, J.; Yoshizawa, M.; Tanimura, Y.; Yoshida, M.; Yamano, T.; Nakaoka, H.

    2004-01-01

    Energy responses of three types of Japanese neutron dose-equivalent (DE) meters were evaluated by Monte Carlo simulations and measurements. The energy responses were evaluated for thermal neutrons, monoenergetic neutrons with energies up to 15.2 MeV, and also for neutrons from such radionuclide sources as 252 Cf and 241 Am-Be. The calculated results were corroborated with the measured ones. The angular dependence of the response and the DE response were also evaluated. As a result, reliable energy responses were obtained by careful simulations of the proportional counter, moderator and absorber of the DE meters. Furthermore, the relationship between pressure of counting gas and response of the DE meter was discussed. By using the obtained responses, relations between predicted readings of the DE meters and true DE values were studied for various workplace spectra

  5. Streamlining Smart Meter Data Analytics

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2015-01-01

    of the so-called big data possible. This can improve energy management, e.g., help utilities improve the management of energy and services, and help customers save money. As this regard, the paper focuses on building an innovative software solution to streamline smart meter data analytic, aiming at dealing......Today smart meters are increasingly used in worldwide. Smart meters are the advanced meters capable of measuring customer energy consumption at a fine-grained time interval, e.g., every 15 minutes. The data are very sizable, and might be from different sources, along with the other social......-economic metrics such as the geographic information of meters, the information about users and their property, geographic location and others, which make the data management very complex. On the other hand, data-mining and the emerging cloud computing technologies make the collection, management, and analysis...

  6. Net metering: zero electricity bill

    International Nuclear Information System (INIS)

    Mangi, A.; Khan, Z.

    2011-01-01

    Worldwide move towards renewable energy sources, environmental concerns and decentralization of the power sector have made net metering an attractive option for power generation at small scale. This paper discusses the net metering, economical issues of renewable sources in Pakistan, technical aspects, installation suitability according to varying terrain, existing utility rules and formulation of legislation for net metering making it economically attractive. (author)

  7. Electro-optical equivalent calibration technology for high-energy laser energy meters

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Ji Feng, E-mail: wjfcom2000@163.com [State Key Laboratory of Precision Measurement Technology and Instrument, Tsinghua University, Beijing 100084 (China); Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China); Graduate School of China Academy of Engineering Physics, Beijing 100088 (China); Key Laboratory of Laser Science and Technology, China Academy of Engineering Physics, Mianyang 621900 (China); Chang, Yan; Zhang, Kai; Hu, Xiao Yang; Zhang, Wei [Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China); Key Laboratory of Laser Science and Technology, China Academy of Engineering Physics, Mianyang 621900 (China); Sun, Li Qun [State Key Laboratory of Precision Measurement Technology and Instrument, Tsinghua University, Beijing 100084 (China)

    2016-04-15

    Electro-optical equivalent calibration with high calibration power and high equivalence is particularly well-suited to the calibration of high-energy laser energy meters. A large amount of energy is reserved during this process, however, which continues to radiate after power-off. This study measured the radiation efficiency of a halogen tungsten lamp during power-on and after power-off in order to calculate the total energy irradiated by a lamp until the high-energy laser energy meter reaches thermal equilibrium. A calibration system was designed based on the measurement results, and the calibration equivalence of the system was analyzed in detail. Results show that measurement precision is significantly affected by the absorption factor of the absorption chamber and by heat loss in the energy meter. Calibration precision is successfully improved by enhancing the equivalent power and reducing power-on time. The electro-optical equivalent calibration system, measurement uncertainty of which was evaluated as 2.4% (k = 2), was used to calibrate a graphite-cone-absorption-cavity absolute energy meter, yielding a calibration coefficient of 1.009 and measurement uncertainty of 3.5% (k = 2). A water-absorption-type high-energy laser energy meter with measurement uncertainty of 4.8% (k = 2) was considered the reference standard, and compared to the energy meter calibrated in this study, yielded a correction factor of 0.995 (standard deviation of 1.4%).

  8. Study of the design variables for a wet-chamber gas meter prototype (MGCH)

    International Nuclear Information System (INIS)

    Patino, Carlos Hernando; Romero, Luis Said; Quiroga, Jabid

    2004-01-01

    This paper established the most important variables and their correlation that affect design and operation of wet-chamber gas meter (MGCH), focused on the gas pressure difference along the meter and the sealing-liquid level. In order to study variable behavior a simulation was carried out based on computational systems The mathematical model developed was built taking into account common features in present wet test gas meter as their internal configuration. Therefore, this work can be understood as a general analysis and its conclusions can be extended to whichever meter of this type. Software was developed to facilitate the analysis of the variables involved in this physical process; besides the drum sizing was modeling using CAD software. As a result of this investigation, theoretical basis were established for the analyzing and designing of a MGCH meter, as a previous phase to the construction and evaluation of the prototype. Uncertainty analysis of each variable implicates in this model was beyond the scope of this study

  9. How to use your peak flow meter

    Science.gov (United States)

    ... meter - how to use; Asthma - peak flow meter; Reactive airway disease - peak flow meter; Bronchial asthma - peak ... 2014:chap 55. National Asthma Education and Prevention Program website. How to use a peak flow meter. ...

  10. Structural design of the Sandia 34-M Vertical Axis Wind Turbine

    Science.gov (United States)

    Berg, D. E.

    Sandia National Laboratories, as the lead DOE laboratory for Vertical Axis Wind Turbine (VAWT) development, is currently designing a 34-meter diameter Darrieus-type VAWT. This turbine will be a research test bed which provides a focus for advancing technology and validating design and fabrication techniques in a size range suitable for utility use. Structural data from this machine will allow structural modeling to be refined and verified for a turbine on which the gravity effects and stochastic wind loading are significant. Performance data from it will allow aerodynamic modeling to be refined and verified. The design effort incorporates Sandia's state-of-the-art analysis tools in the design of a complete machine. The analytic tools used in this design are discussed and the conceptual design procedure is described.

  11. Development of a pressure based vortex-shedding meter: measuring unsteady mass-flow in variable density gases

    International Nuclear Information System (INIS)

    Ford, C L; Winroth, M; Alfredsson, P H

    2016-01-01

    An entirely pressure-based vortex-shedding meter has been designed for use in practical time-dependent flows. The meter is capable of measuring mass-flow rate in variable density gases in spite of the fact that fluid temperature is not directly measured. Unlike other vortex meters, a pressure based meter is incredibly robust and may be used in industrial type flows; an environment wholly unsuitable for hot-wires for example. The meter has been tested in a number of static and dynamic flow cases, across a range of mass-flow rates and pressures. The accuracy of the meter is typically better than about 3% in a static flow and resolves the fluctuating mass-flow with an accuracy that is better than or equivalent to a hot-wire method. (paper)

  12. Community Net Energy Metering: How Novel Policies Expand Benefits of Net Metering to Non-Generators

    Energy Technology Data Exchange (ETDEWEB)

    Rose, James; Varnado, Laurel

    2009-04-01

    As interest in community solutions to renewable energy grows, more states are beginning to develop policies that encourage properties with more than one meter to install shared renewable energy systems. State net metering policies are evolving to allow the aggregation of multiple meters on a customer’s property and to dissolve conventional geographical boundaries. This trend means net metering is expanding out of its traditional function as an enabling incentive to offset onsite customer load at a single facility. This paper analyzes community net energy metering (CNEM) as an emerging vehicle by which farmers, neighborhoods, and municipalities may more easily finance and reap the benefits of renewable energy. Specifically, it aims to compare and contrast the definition of geographical boundaries among different CNEM models and examine the benefits and limitations of each approach. As state policies begin to stretch the geographic boundaries of net metering, they allow inventive solutions to encourage renewable energy investment. This paper attempts to initiate the conversation on this emerging policy mechanism and offers recommendations for further development of these policies.

  13. Sector smart meter audit review report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-03-31

    This paper presented the results of an electricity distributor sector smart meter audit review conducted by the Ontario Energy Board (OEB) for the period of January 1, 2006 to September 30, 2009. The review summarized the results of a questionnaire related to distributors' smart meter regulatory accounting treatment. Seventy-eight distributors responded to the survey. The review included details of: (1) total investments in smart metering initiative for capital expenditures (CAPEX) and operating maintenance and administrative expenses (OM and A), (2) funding dollars received by the distributors, (3) board-approved recoveries for CAPEX and OM and A, (4) recorded stranded meter costs, and (5) number of smart meters installed in the review period. The audit review demonstrated that some distributors incorrectly recorded carrying charges related to smart meter OM and A expenses, and that some smart meter transactions were recorded in accounts other than OEB established accounts in the general ledger. Results of the audit will be used to provide further accounting assistance to electricity distributors. 7 tabs.

  14. Numerical Evaluation of Averaging BDFT(bidirectional flow tube) Flow Meter on Applicability in the Fouling Condition

    International Nuclear Information System (INIS)

    Park, J. P.; Jeong, J. H.; Yuna, B. J.; Jerng, D. W.

    2013-01-01

    The results show that the averaging BDFT is a promising flow meter for the accurate measurement of flow rates in the fouling condition of the NPPs. A new instrumentation, an averaging BDFT, was proposed to measure the accurate flow rate under corrosion environment. In this study, to validate the applicability of the averaging BDFT on the fouling conditions, flow analyses using the CFD code were performed. Analyses results show that this averaging BDFT does not lose the measuring performance even under the corrosion environment. Therefore, it is expected that the averaging BDFT can replace the type flow meters for the feedwater pipe of steam generator of NPPs. Most of the NPPs adopt pressure difference type flow meters such as venturi and orifice meters for the measurement of feedwater flow rates to calculate reactor thermal power. However, corrosion products in the feedwater deposits on the flow meter as operating time goes. These effects lead to severe errors in the flow indication and then determination of reactor thermal power. The averaging BDFT has a potentiality to minimize this problem. Therefore, it is expected that the averaging BDFT can replace the type venturi meters for the feedwater pipe of steam generator of NPPs. The present work compares the amplification factor, K, based on CFD calculation against the K obtained from experiments in order to confirm whether a CFD code can be applicable to the evaluation of characteristic for the averaging BDFT. In addition to this, the simulations to take into account of fouling effect are also carried out by rough wall option

  15. Hardware Design of a Smart Meter

    OpenAIRE

    Ganiyu A. Ajenikoko; Anthony A. Olaomi

    2014-01-01

    Smart meters are electronic measurement devices used by utilities to communicate information for billing customers and operating their electric systems. This paper presents the hardware design of a smart meter. Sensing and circuit protection circuits are included in the design of the smart meter in which resistors are naturally a fundamental part of the electronic design. Smart meters provides a route for energy savings, real-time pricing, automated data collection and elimina...

  16. Smart Metering Guide. Energy Saving and the Customer. Edition 2010

    Energy Technology Data Exchange (ETDEWEB)

    Kester, J.C.P. (ed.) [Energy research Centre of the Netherlands ECN, Petten (Netherlands); Gonzalez Burgos, M.J. (ed.) [Endesa Ingenieria, Madrid (Spain); Parsons, J. (ed.) [British Electrotechnical and Allied Manufacturers Association BEAMA, London (United Kingdom)

    2010-11-15

    Smart metering can provide the foundations for a radically different approach to energy reduction schemes. However, the implementation of smart metering is a complex undertaking and its success depends on getting many factors right, from technology choice to how the information is presented to final customers. Making the expected reduction in energy consumption depends on achieving a positive reaction from final customers. Maintaining and increasing these savings will need the engagement of Energy Retailers, energy agencies and others. This Guide has been produced to bring together the lessons learnt from smart metering systems and trials, targeted on the promotion of End Use Energy Efficiency. The aim is to assist those groups who are considering implementing smart metering for this purpose and to maximise the benefits arising from those implementations. . The main target audience for the Guide are utilities, ESCO's and service providers across Europe. In most countries these are the parties investing in the smart metering systems and providing the smart metering services. In addition to these, governments, regulators, consumer bodies and energy agencies, as well as suppliers and system integrators, will also find valuable information in the Guide. As the subtitle of the Guide indicates, the focus of this Guide is on the application of smart metering for delivering energy saving. Making the expected reduction in energy consumption depends on achieving a positive reaction from final customers. In general, the successful provision of smart metering services is highly dependent on the right involvement of the energy final customer. This guide is not a ready-to-go manual for the installation of a specific type of smart metering system. Rather, the authors have tried to give the reader an insight into some of the complexities of the whole implementation process of smart metering systems. Also the guide is impartial regarding different technologies unless there is

  17. Optical cycle power meter

    DEFF Research Database (Denmark)

    2014-01-01

    A bicycle power meter for measuring power generated when riding a bicycle, the power meter comprising a position-sensitive radiation detector (409) attachable to a component of a crank set (404) of bicycle, and a radiation source (408) attachable to the component of the crank set and configured t...

  18. Double-multiple streamtube model for studying vertical-axis wind turbines

    Science.gov (United States)

    Paraschivoiu, Ion

    1988-08-01

    This work describes the present state-of-the-art in double-multiple streamtube method for modeling the Darrieus-type vertical-axis wind turbine (VAWT). Comparisons of the analytical results with the other predictions and available experimental data show a good agreement. This method, which incorporates dynamic-stall and secondary effects, can be used for generating a suitable aerodynamic-load model for structural design analysis of the Darrieus rotor.

  19. Alpha particle response for a prototype radiation survey meter based on poly(ethylene terephthalate) with un-doping fluorescent guest molecules

    International Nuclear Information System (INIS)

    Nguyen, Philip; Nakamura, Hidehito; Sato, Nobuhiro; Takahashi, Tomoyuki; Maki, Daisuke; Kanayama, Masaya; Takahashi, Sentaro; Kitamura, Hisashi; Shirakawa, Yoshiyuki

    2016-01-01

    There is no radiation survey meter that can discriminate among alpha particles, beta particles, and gamma-rays with one material. Previously, undoped poly(ethylene terephthalate) (PET) has been shown to be an effective material for beta particle and gamma-ray detection. Here, we demonstrate a prototype survey meter for alpha particles based on undoped PET. A 140 × 72 × 1-mm PET substrate was fabricated with mirrored surfaces. It was incorporated in a unique detection section of the survey meter that directly detects alpha particles. The prototype exhibited an unambiguous response to alpha particles from a 241 Am radioactive source. These results demonstrate that undoped PET can perform well in survey meters for alpha particle detection. Overall, the PET-based survey meter has the potential to detect multiple types of radiation, and will spawn an unprecedented type of radiation survey meter based on undoped aromatic ring polymers. (author)

  20. Performance of a new meter designed for assisted monitoring of blood glucose and point-of-care testing.

    Science.gov (United States)

    Macrury, Sandra; Srinivasan, Aparna; Mahoney, John J

    2013-03-01

    Blood glucose (BG) meters used for assisted monitoring of blood glucose (AMBG) require different attributes compared with meters designed for home use. These include safety considerations (i.e., minimized risk of blood-borne pathogen transmission), capability for testing multiple blood sample types, and enhanced performance specifications. The OneTouch® Verio™Pro+ BG meter is designed to incorporate all of these attributes. Meter accuracy was assessed in clinical studies with arterial, venous, and capillary blood samples with a hematocrit range of 22.9-59.8%. The effect of interferents, including anticoagulants, on accuracy was evaluated. The meter disinfection protocol was validated, and instructions for use and user acceptance of the system were assessed. A total of 97% (549/566) of BG measures from all blood sample types and 95.5% (191/200) of arterial blood samples were within ±12 mg/dl or 12.5% of reference measurements. The system was unaffected by 4 anticoagulants and 57 of 59 endogenous and exogenous compounds; it was affected by 2 compounds: pralidoxime iodide and xylose. Bleach wipes were sufficient to disinfect the meter. Users felt that the meter's quality control (QC) prompts would help them to comply with regulatory requirements. The meter provided accurate measurements of different blood samples over a wide hematocrit range and was not affected by 57 physiologic and therapeutic compounds. The QC prompts and specific infection-mitigating design further aid to make this meter system practical for AMBG in care facilities. © 2013 Diabetes Technology Society.

  1. Ramp metering with an objective to reduce fuel consumption

    OpenAIRE

    Vreeswijk, Jacob Dirk; Woldeab, Zeremariam; de Koning, Anne; Bie, Jing

    2011-01-01

    Ramp meters successfully decrease congestion but leave a burden on the traffic situation at on-ramps. Chaotic queuing leads to many stop-and-go movements and causes inefficiency where fuel consumption is concerned. As part of the eCoMove project, complementary strategies are being designed and evaluated to reduce fuel consumption at metered on-ramps, using vehicle-to-infrastructure communication. This paper presents the design of two strategies, as well as their effect as derived from simulat...

  2. Net metering in British Columbia : white paper

    International Nuclear Information System (INIS)

    Berry, T.

    2003-01-01

    Net metering was described as being the reverse registration of an electricity customer's revenue meter when interconnected with a utility's grid. It is a provincial policy designed to encourage small-distributed renewable power generation such as micro-hydro, solar energy, fuel cells, and larger-scale wind energy. It was noted that interconnection standards for small generation is an important issue that must be addressed. The British Columbia Utilities Commission has asked BC Hydro to prepare a report on the merits of net metering in order to support consultations on a potential net metering tariff application by the utility. This report provides information on net metering with reference to experience in other jurisdictions with net metering, and the possible costs and benefits associated with net metering from both a utility and consumer perspective. Some of the barriers and policy considerations for successful implementation of net metering were also discussed. refs., tabs., figs

  3. Feasibility Study of Power Uprate Using Ultrasonic Flow Meters in NPPs

    International Nuclear Information System (INIS)

    Kim, Tae Mi; Heo, Gyun Young

    2010-01-01

    Feedwater flowrate is an important input parameter in establishing the plant's operating power level. In Korean nuclear power plants, venturi flow meters have been used for measuring the feedwater flow of the secondary side. However, as time goes on, the fouling in venture meters could cause measurement uncertainties to grow and that could lead to operation at less than about 2% of the licensed thermal power limit. In order to resolve the problem, nuclear power plants in other countries use Ultrasonic Flow Meters (UFMs) which have relatively lower measurement uncertainty (about 0.5%) instead of venturi flow meters and have reduced the errors from the fouling in venturi-type flow meters. USA amended 10 CFR 50 Appendix K so that US nuclear power plants can use real value of Core Operating Limit Supervisory System (COLSS) uncertainty, which is currently fixed as 2%, by adopting the UFM. Korea also has been amended the law in order to get benefits from the technology. In this study, we are going to present the fundamental principles of UFMs and the advantages and disadvantages of its installation. Also, we inquire into the conventional uses of UFMs in the overseas sites and then check what is needed to consider for its domestic application

  4. Flow measurement of liquid hydrocarbons with positive displacement meters: the correction for slippage

    International Nuclear Information System (INIS)

    García-Berrocal, Agustín; Montalvo, Cristina; Balbás, Miguel; Blázquez, Juan

    2013-01-01

    In the oil industry, the economical and fiscal impact of the measurements accuracy on the custody transfer operations implies fulfilling strict requirements of legal metrology. In this work, we focus on the positive displacement meters (PD meters) for refined liquid hydrocarbons. The state of the art of the lack of accuracy due to slippage flow in these meters is revised. The slippage flow due to the pressure drop across the device has been calculated analytically by applying the Navier–Stokes equation. No friction with any wall of the slippage channel has been neglected and a more accurate formula than the one found in the literature has been obtained. PD meters are calibrated against a bidirectional prover in order to obtain their meter factor which allows correction of their indications. Instead of the analytical model, an empirical one is proposed to explain the variation of the meter factor of the PD meters with flow rate and temperature for a certain hydrocarbon. The empirical model is based on the historical calibration data, of 9 years on average, of 25 m with four types of refined hydrocarbon. This model has been statistically validated by linear least-squares fitting. By using the model parameters, we can obtain the meter factor corresponding to different conditions of temperature and flow rate from the conditions in which the devices were calibrated. The flow parameter is such that a 10% flow rate variation implies a meter factor variation lower than 0.01%. A rule of thumb value for the temperature parameter is 0.005% per degree Celsius. The model residuals allow surveillance of the device drift and quantifying its contribution to the meter factor uncertainty. The observed drift is 0.09% at 95% confidence level in the analyzed population of meters. (paper)

  5. Application of a commercial diffusion type carbon meter in a sodium circuit

    International Nuclear Information System (INIS)

    Bhat, N.P.; Borgstedt, H.U.; Peric, Z.; Witting, G.

    1980-01-01

    The exchange of carbon between structural materials and liquid sodium influences the mechanical properties of components of the cooling circuits. Therefore, the estimation of the carbon content of the alkali metal and the knowledge of its carburizing potential is of importance. Since some years the measurement of the carburizing potential of sodium is easy to perform by the application of the foil equilibration method which leads to good results in spite of the very low carbon concentrations in the liquid metal. Thin foils (0.025 to 0.125 mm) of Fe-18Cr-8Ni-C alloy (corresponding to stainless steel type AISI 304) are immersed in sodium at 550 to 700 deg. C for 200 to 400 hours. The equilibrium of the carbon distribution must be reached. Chemical analyses of the steel tabs and relation of concentration to activity of carbon lead to information on the carbon concentration in the sodium, if the saturation concentration of carbon in sodium is known. The method gives arbitrary values over a longer period of time. The time needed for equilibration and analysis causes a delay for the getting of results. Therefore, there is a need for instruments which are capable to measure carbon directly in the circuits and give continuously information on the actual carbon activities in the fluid. Until 1975 only one carbon meter was commercially available. One unit in was tested a chemical analytical sodium circuit

  6. A final report to investigate the state-of-the-art of district heating metering systems

    Energy Technology Data Exchange (ETDEWEB)

    1981-06-01

    This study investigates the existing heat meters and metering schemes utilized to measure the amount of energy extracted from a district heating hot water supply by a heat exchanger in domestic applications. Various types of commercially available heat meters are tabulated, including a recently developed Dutch device which output an analogue signal proportional to the energy extracted. Discussions outline methods of potentially cost effective multimetering concepts for use in new housing and apartment applications, as well as single family dwelling units. Data retrieval systems, with potential metering/monitoring schemes are discussed, including a proposed network for remote sensing, central integrating and tabulating function applicable to multi-dwelling unit installations. 5 refs., 9 figs., 1 tab.

  7. 40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...

  8. ATD-2 Surface Scheduling and Metering Concept

    Science.gov (United States)

    Coppenbarger, Richard A.; Jung, Yoon Chul; Capps, Richard Alan; Engelland, Shawn A.

    2017-01-01

    This presentation describes the concept of ATD-2 tactical surface scheduling and metering. The concept is composed of several elements, including data exchange and integration; surface modeling; surface scheduling; and surface metering. The presentation explains each of the elements. Surface metering is implemented to balance demand and capacity• When surface metering is on, target times from surface scheduler areconverted to advisories for throttling demand• Through the scheduling process, flights with CTOTs will not get addedmetering delay (avoids potential for ‘double delay’)• Carriers can designate certain flights as exempt from metering holds• Demand throttle in Phase 1 at CLT is through advisories sent to rampcontrollers for pushback instructions to the flight deck– Push now– Hold for an advised period of time (in minutes)• Principles of surface metering can be more generally applied to otherairports in the NAS to throttle demand via spot-release times (TMATs Strong focus on optimal use of airport resources• Flexibility enables stakeholders to vary the amount of delay theywould like transferred to gate• Addresses practical aspects of executing surface metering in aturbulent real world environment• Algorithms designed for both short term demand/capacityimbalances (banks) or sustained metering situations• Leverage automation to enable surface metering capability withoutrequiring additional positions• Represents first step in Tactical/Strategic fusion• Provides longer look-ahead calculations to enable analysis ofstrategic surface metering potential usage

  9. Design of a wind turbine-generator system considering the conformability to wind velocity fluctuations

    Energy Technology Data Exchange (ETDEWEB)

    Wakui, Tetsuya; Hashizume, Takumi; Outa, Eisuke

    1999-07-01

    The conformability of the rated power output of the wind turbine-generator system and of the wind turbine type to wind velocity fluctuations are investigated with a simulation model. The authors examine three types of wind turbines: the Darrieus-Savonius hybrid, the Darrieus proper and the Propeller. These systems are mainly operated at a constant tip speed ratio, which refers to a maximum power coefficient points. As a computed result of the net extracting power, the Darrieus turbine proper has little conformability to wind velocity fluctuations because of its output characteristics. As for the other turbines, large-scale systems do not always have an advantage over small-scale systems as the effect of its dynamic characteristics. Furthermore, it is confirmed that the net extracting power of the Propeller turbine, under wind direction fluctuation, is much reduced when compared with the hybrid wind turbine. Thus, the authors conclude that the appropriate rated power output of the system exists with relation to the wind turbine type for each wind condition.

  10. Additional functions of remotely read kWh-meters

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P [VTT Energy, Espoo (Finland); Vehvilaeinen, S [Mittrix Oy (Finland); Rantanen, J [Helsinki Energy Board (Finland)

    1998-08-01

    In this chapter the possibilities to include new applications into remotely read smart kWh-meters are considered. New electronic meters can measure various electric quantities and have some extra calculating capacity. So they can be used to provide functions that distribution automation and the customer need and thus share the costs. Some applications like monitoring the state of the distribution network or locating faults are only for the utility, but many applications also need an interface to the customers or their automation systems. Among those are monitoring the quality of electricity, estimating load curves, applying dynamic tariffs and selling electricity and accounting. As a special item, the continuous monitoring of the quality of electricity is discussed. This includes voltage levels, total distortion, asymmetry and so on. If such a kWh-meter indicates quality problems it is possible to go there with a portable quality meter that is suitable for the case and inspect the situation. The poor quality can be detected before it causes harm to equipment owned by the customers or the power distribution company. This article also presents a prototype of such a quality monitoring kWh-meter. Dynamic tariffs and free electricity markets require two way communication with the utility and the customer and measurement of the time variations of the energy consumption. The customers or their energy management system must receive the energy prices from the utility and calculate the energy costs and decide upon the energy consumption control actions. Some alternative ways to meet these customer interface requirements are compared. Remote reading of kWh-meters requires a certain investment in meters and their data communication with the utility. Because smart meters can have some additional memory and calculating capacity and are capable of measuring various electric quantities, it is possible to share the costs with other applications that use the same hardware and data

  11. Digital reactivity meter

    International Nuclear Information System (INIS)

    Akkus, B.; Anac, H.; Alsan, S.; Erk, S.

    1991-01-01

    Nowadays, various digital methods making use of microcomputers for neutron detector signals and determining the reactivity by numerical calculations are used in reactor control systems in place of classical reactivity meters. In this work, a calculation based on the ''The Time Dependent Transport Equation'' has been developed for determining the reactivity numerically. The reactivity values have been obtained utilizing a computer-based data acquisition and control system and compared with the analog reactivity meter values as well as the values calculated from the ''Inhour Equation''

  12. Calculations of dosimetric parameter and REM meter response for BE(d, n) source

    International Nuclear Information System (INIS)

    Chen Changmao

    1988-01-01

    Based on the recent data about neutron spectra, the average energy, effictive energy and conversion coefficient of fluence to dose equivalent are calculated for some Be (α, n) neutron sources which have differene types and structures. The responses of 2202D and 0075 REM meter for thses spectral neutrons are also estimated. The results indicate that the relationship between average energy and conversion coefficient or REM meter responses can be described by simple functions

  13. A radon meter chamber

    International Nuclear Information System (INIS)

    Carlsson, R.

    1990-01-01

    The meter consists of a cylindrical house with two openings, at the ends, one of which is equipped with an alpha particle detector and the other covered with a metal net. The house is manufactured in an isolating material e.g. plastic, with a metallic layer applied to all internal surfaces. The metallic layer and net are kept at a positive electric potential, compared to the alpha detector, in order to attract the radon daughters to the detector and achieve a high efficiency. (L.E.)

  14. Determining the ash content of coal flotation tailings using an MPOF optical ash meter

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, T; Sliwa, J

    1982-01-01

    The block layout, a description of the design and principles of operation of an automatic optical, continuous action MPOF type ash meter are presented. The difference in the optical properties of coal and rock is used in the ash meter. The identification of the ash content is conducted on the basis of the spectral characteristics of reflection of a finely dispersed aqueous coal and rock suspension.

  15. Theoretical comparison of performance using transfer functions for reactivity meters based on inverse kinetic method and simple feedback method

    International Nuclear Information System (INIS)

    Shimazu, Yoichiro; Tashiro, Shoichi; Tojo, Masayuki

    2017-01-01

    The performance of two digital reactivity meters, one based on the conventional inverse kinetic method and the other one based on simple feedback theory, are compared analytically using their respective transfer functions. The latter one is proposed by one of the authors. It has been shown that the performance of the two reactivity meters become almost identical when proper system parameters are selected for each reactivity meter. A new correlation between the system parameters of the two reactivity meters is found. With this correlation, filter designers can easily determine the system parameters for the respective reactivity meters to obtain identical performance. (author)

  16. Automated borehole gravity meter system

    International Nuclear Information System (INIS)

    Lautzenhiser, Th.V.; Wirtz, J.D.

    1984-01-01

    An automated borehole gravity meter system for measuring gravity within a wellbore. The gravity meter includes leveling devices for leveling the borehole gravity meter, displacement devices for applying forces to a gravity sensing device within the gravity meter to bring the gravity sensing device to a predetermined or null position. Electronic sensing and control devices are provided for (i) activating the displacement devices, (ii) sensing the forces applied to the gravity sensing device, (iii) electronically converting the values of the forces into a representation of the gravity at the location in the wellbore, and (iv) outputting such representation. The system further includes electronic control devices with the capability of correcting the representation of gravity for tidal effects, as well as, calculating and outputting the formation bulk density and/or porosity

  17. A simple reactivity-meter system

    International Nuclear Information System (INIS)

    Ferreira, P.S.B.

    1992-01-01

    This paper describes a new version of a reactivity meter developed at the Institute of Nuclear Energy Research (IPEN) (Brazil). The reactivity meter computes the reactor reactivity utilizing a programmable electrometer that performs the data aquisition. The software commands the main functions of the electrometer, the data acquisition, data transfer, and reactivity calculation. The necessary hardware for this reactivity meter are a programmable electrometer, a microcomputer, and interfaces for the microcomputer to communicate with the electrometer. If it is necessary, it is possible to connect a graphic register to the microcomputer. With this conventional hardware, available in any nuclear reactor facility, one can build a powerful reactivity meter. Adding to these advantages, one can use the microcomputer on-line to analyze the data, store the data on diskettes, or create graphics

  18. MULTICHANNEL DISTRIBUTION METER: A VERITABLE ...

    African Journals Online (AJOL)

    eobe

    Usually, commercial home owners preferred the installation of one or few .... communication (GSM) based solution were presented. The authors ... meters. The proposed meters in their work uses .... The most probable data entry component to ...

  19. Hydro Ottawa achieves Smart Meter milestone

    International Nuclear Information System (INIS)

    Anon.

    2008-01-01

    As Ontario's second largest municipal electricity company, Hydro Ottawa serves more than 285,000 residential and business customers in the city of Ottawa and the village of Casselman. Since 2006, the utility has installed more than 230,000 Smart Meters throughout its service territory in an effort to provide better services to its customers. This initiative represents the largest operational advanced metering infrastructure network in Canada. This move was necessary before time-of-use rates can be implemented in Ottawa. The Smart Meters deliver data wirelessly to Hydro Ottawa's Customer Information System for billing and eliminating manual readings. The Smart Meters are designed to promote more efficient use of electricity. The Government of Ontario has passed legislation requiring the installation of Smart Meters throughout the province by the end of 2010

  20. How Satisfied Are Patients When Their Choice of Funded Glucose Meter Is Restricted to a Single Brand?

    Science.gov (United States)

    Macdonald, Christy; Lunt, Helen; Downie, Michelle; Kendall, Deborah

    2017-09-01

    Many governments and insurers are driving down the cost of medical devices, including glucose meters, by the central management of purchasing decisions. We report patients' responses to an "enforced" change in brand of glucose meter, one year after the introduction of a national sole supplier arrangement for funded glucose meters and strips. Specialist diabetes clinic attendees from two geographical locations completed a questionnaire one year after the final meter changeover date. In the first location, consecutive patients were asked to complete a glucose meter satisfaction questionnaire during their clinic visit. In the second location, this questionnaire was mailed to clinic attendees. Responses to open questions were analyzed thematically. Response rates were 85% and 31% from the first and second locations, respectively and 378 questionnaires were suitable for analysis, 309 from the first and 69 from the second location. Insulin users composed 90% of participants. Results from the two locations were broadly similar. Most participants adapted well to the changeover, however 36% reported ongoing dissatisfaction with their "new" meter. The commonest concern, expressed by 23% of participants, related to meter accuracy and precision. One year after glucose meter changeover, a third of participants expressed dissatisfaction with their meter, with many participants describing a failure to adapt to the sole supplier arrangement. Providing a choice of meters and strips, ideally from two or more brands that have demonstrable differences in technical and ergonomic features, is likely to produce higher overall patient satisfaction than is a sole supplier arrangement.

  1. PELATIHAN LARI AEROBIK 400 METER TIGA REPETISI DUA SET DAN DUA REPETISI TIGA SET SELAMA 6 MINGGU SAMA-SAMA MENINGKATKAN KECEPATAN JALAN CEPAT 3000 METER SISWA KELAS VII SMPN 11 DENPASAR

    Directory of Open Access Journals (Sweden)

    Dixon E.M. Taek Bete

    2014-08-01

    Full Text Available Monitoring the author has been in SMP 11 Denpasar.They had never achieved maximum performance (champion in the number of brisk walking.Because by declining student motivation, student interest because it appears more inclined to form other sports, such as volleyball ball games, soccer, futsall, table tennis or badminton or perhaps training methods that do not follow the principles of training required. The purpose of this training is to determine an increase in the speed of a brisk walk 3000 meters against both treatment groups. This study used an experimental method. Population is taken from class VII SMP Denpasar. This study used an experimental method. Population is taken from class VII SMP Denpasar. Samples are 32 people drawn randomly from the population who meet the inclusion and exclusion criteria. The number of samples divided into two groups with each group consisting of 16 people. The training is done with a frequency 4 times a week for 6 weeks. The first group was given 400-meter aerobic training run two sets of three reps and group II aerobic training 400 meter run three sets of two reps. Data in the form of brisk walking 3000 meter results taken before and after training. The data obtained were tested using SPSS computer program. The data were normally distributed and homogeneous so that further tested using paired t-test to compare mean values ??before and after training between each group, while the independent t-test to determine differences in mean values ??between the two groups. Paired t-test results of Group I and Group II were significantly increased (p <0.05. The results of independent t-test found that the two groups before the training was not significant (p> 0.05, whereas both groups after training pace brisk walking are equally increased (p> 0.05. Conclusion that aerobic training 400 meter run two sets of three reps and three sets of two reps for 6 weeks together (not significant increase the speed of a brisk walk 3000

  2. Probing attentive and preattentive emergent meter in adult listeners without extensive music training

    NARCIS (Netherlands)

    Ladinig, O.; Honing, H.; Háden, G.; Winkler, I.

    2009-01-01

    Beat and meter induction are considered important structuring mechanisms underlying the perception of rhythm. Meter comprises two or more levels of hierarchically ordered regular beats with different periodicities. When listening to music, adult listeners weight events within a measure in a

  3. Privacy-Preserving Meter Report Protocol of Isolated Smart Grid Devices

    Directory of Open Access Journals (Sweden)

    Zhiwei Wang

    2017-01-01

    Full Text Available Smart grid aims to improve the reliability, efficiency, and security of the traditional grid, which allows two-way transmission and efficiency-driven response. However, a main concern of this new technique is that the fine-grained metering data may leak the personal privacy information of the customers. Thus, the data aggregation mechanism for privacy protection is required for the meter report protocol in smart grid. In this paper, we propose an efficient privacy-preserving meter report protocol for the isolated smart grid devices. Our protocol consists of an encryption scheme with additively homomorphic property and a linearly homomorphic signature scheme, where the linearly homomorphic signature scheme is suitable for privacy-preserving data aggregation. We also provide security analysis of our protocol in the context of some typical attacks in smart grid. The implementation of our protocol on the Intel Edison platform shows that our protocol is efficient enough for the physical constrained devices, like smart meters.

  4. Radiation dose rate meter

    International Nuclear Information System (INIS)

    Kronenberg, S.; Siebentritt, C.R.

    1981-01-01

    A combined dose rate meter and charger unit therefor which does not require the use of batteries but on the other hand produces a charging potential by means of a piezoelectric cylinder which is struck by a manually triggered hammer mechanism. A tubular type electrometer is mounted in a portable housing which additionally includes a geiger-muller (Gm) counter tube and electronic circuitry coupled to the electrometer for providing multi-mode operation. In one mode of operation, an rc circuit of predetermined time constant is connected to a storage capacitor which serves as a timed power source for the gm tube, providing a measurement in terms of dose rate which is indicated by the electrometer. In another mode, the electrometer indicates individual counts

  5. A wide range survey meter for estimating γ- and β-dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1980-09-01

    A survey meter has been developed to measure β-dose rates in the range 0.1 - 100 rad/h (1 mGy/h - 1 Gy/h) and γ-dose rates in the range 1 mrad/h - 100 rad/h (10 μGy/h-1 Gy/h). It also provides an audible warning of high γ-dose rates and an audible and visible warning when a predetermined γ-dose is exceeded. The report describes the design of the survey meter and presents data measured on the performance of an engineering prototype. Factors which affect performance and have been investigated are temperature, battery voltage (and type of battery), GM counter counting loss, direction of incident radiation, and energy of γ-rays. Finally, the application and calibration of the survey meter are discussed. (auth)

  6. Justification of the Utility of Introducing Smart Meters in Latvia

    Science.gov (United States)

    Kunickis, M.; Dandens, A.; Bariss, U.

    2015-12-01

    Automatic data reading from smart meters is being developed in many parts of the world, including Latvia. The key drivers for that are developments of smart technologies and economic benefits for consumers. Deployment of smart meters could be launched in a massive scale. Several pilot projects were implemented to verify the feasibility of smart meters for individual consumer groups. Preliminary calculations indicate that installation of smart meters for approximately 23 % of electricity consumers would be economically viable. Currently, the data for the last two years is available for an in-depth mathematical analysis. The continuous analysis of consumption data would be established, when more measurements from smart meters are available. The extent of introduction of smart meters should be specified during this process in order to gain the maximum benefit for the whole society (consumers, grid companies, state authorities), because there are still many uncertain and variable factors. For example, it is necessary to consider statistical load variations by hour, dependence of electricity consumption on temperature fluctuations, consumer behaviour and demand response to market signals to reduce electricity consumption in the short and long term, consumer's ambitions and capability to install home automation for regulation of electricity consumption. To develop the demand response, it is necessary to analyse the whole array of additional factors, such as expected cost reduction of smart meters, possible extension of their functionality, further development of information exchange systems, as well as standard requirements and different political and regulatory decisions regarding the reduction of electricity consumption and energy efficiency.

  7. Characteristic tests of ionization chamber and GM counter survey meters for beta-rays, (2)

    International Nuclear Information System (INIS)

    Suga, Shin-ichi; Bingo, Kazuyoshi; Kajimoto, Yoichi

    1979-03-01

    To estimate a beta-ray absorbed dose rate of contaminated skin, measurements were done twice by a survey meter without and with a filter, keeping the distance from the contaminated skin surface to the survey meter at 10 mm. The absorbed dose rate was obtained multiplying a net reading (equals a reading of survey meter's indicator measured without the filter minus that measured with the filter) by a multiplying factor. Calibrations were made with reference plane sources of natural uranium, 198 Au and 204 Tl, varying their area. The five types of ionization chamber survey meters had nearly same multiplying factors when the diameter of source was larger than the diameter of the chamber cylinder. Estimation of the absorbed doses due to beta-emitting nuclides was possible when the measured value without filter was larger by 20% or more than that of with filter. In the case of small sources, the multiplying factor varied significantly with area of the source. The multiplying factors agreed within +-30% in the respective types i.e. manufacturers and in maximum beta-ray energies from 0.7 up to 2.5 MeV. In the source to detector distance of 1 cm +-0.2 cm, the multiplying factor varied within +-20%. The multiplying factor of a GM counter survey meter varied with beta-ray energy, the multiplying factor for uranium was 1/3 that of 204 Tl. (author)

  8. Accurate KAP meter calibration as a prerequisite for optimisation in projection radiography

    International Nuclear Information System (INIS)

    Malusek, A.; Sandborg, M.; Alm Carlsson, G.

    2016-01-01

    Modern X-ray units register the air kerma-area product, PKA, with a built-in KAP meter. Some KAP meters show an energy-dependent bias comparable with the maximum uncertainty articulated by the IEC (25 %), adversely affecting dose-optimisation processes. To correct for the bias, a reference KAP meter calibrated at a standards laboratory and two calibration methods described here can be used to achieve an uncertainty of <7 % as recommended by IAEA. A computational model of the reference KAP meter is used to calculate beam quality correction factors for transfer of the calibration coefficient at the standards laboratory, Q 0 , to any beam quality, Q, in the clinic. Alternatively, beam quality corrections are measured with an energy-independent dosemeter via a reference beam quality in the clinic, Q 1 , to beam quality, Q. Biases up to 35 % of built-in KAP meter readings were noted. Energy-dependent calibration factors are needed for unbiased PKA. Accurate KAP meter calibration as a prerequisite for optimisation in projection radiography. (authors)

  9. Radioisotope conveyor ash meter

    International Nuclear Information System (INIS)

    Savelov, V.D.

    1994-01-01

    Radioisotope conveyor ash meter realizes persistent measuring of ashiness of coal and products of its enrichment on the belt conveyor without contact. The principle of ash meter acting is based on functional dependence of the gamma radiation flows backscattering intensity of radioisotope sources from the ash volume content in the controlled fuel. Facility consists from the ashiness transducer and the processing and control device

  10. Performance testing of Tesla NNG 601 activity meter in nuclear medicine department

    International Nuclear Information System (INIS)

    Husak, V.; Kleinbauer, K.

    1980-01-01

    The results are presented of testing activity meter Tesla NNG 601 the production of which began in Czechoslovakia in 1978. The meter is provided with a shielded well-type ionization chamber, the well 42 mm in diameter and 140 mm deep. The parameters of the instrument linearity, volume dependence, accuracy and stability, correctness of calibration were compared with those of other instruments (Searle Analytic, Picker and Capinted). The volume dependence of the Czechoslovak NNG 601 instrument is higher than that in the other instruments, other parameters are the same of better

  11. Intelligent Metering for Urban Water: A Review

    OpenAIRE

    Rodney Stewart; Stuart White; Candice Moy; Ariane Liu; Pierre Mukheibir; Damien Giurco; Thomas Boyle

    2013-01-01

    This paper reviews the drivers, development and global deployment of intelligent water metering in the urban context. Recognising that intelligent metering (or smart metering) has the potential to revolutionise customer engagement and management of urban water by utilities, this paper provides a summary of the knowledge-base for researchers and industry practitioners to ensure that the technology fosters sustainable urban water management. To date, roll-outs of intelligent metering have been ...

  12. Strategy of the spread of automatic meter reading for 10 million customers

    International Nuclear Information System (INIS)

    Okano, H.; Koyanagi, A.

    1997-01-01

    In response to the major changes now taking place in its business environment, Tokyo Gas will restructure its meter-reading operations, including services peripheral thereto, to build a strong corporate structure toward the year 2010. Specifically, Tokyo Gas will proceed to intentional automatic meter reading, making use of the know-how it has accumulated doing so as part of a value-added service it has been marketing since 1988. Tokyo Gas will also use its two-way communication infrastructure to promote improved operational efficiency and labor savings. Intentional automatic meter reading will enable Tokyo Gas, over the 13 years following its commencement, to realize total cost savings of 53.5 billion yen and reassign 776 employers to strategic work. Tokyo Gas will also utilize its two-way communication infrastructure to provide additional services, including value-added services that will generate upwards of 3.7 billion yen margin annually and contracted meter reading services for utilities throughout Japan. Tokyo Gas will thus carry out a business expansion that will enable it to grow limitlessly together with society. (au)

  13. Critical review of directional neutron survey meters

    International Nuclear Information System (INIS)

    Balmer, Matthew J.I.; Gamage, Kelum A.A.; Taylor, Graeme C.

    2014-01-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument. -- Highlights: • We critically review the existing literature into directional survey meters. • Instruments which could be adapted for this purpose are also reviewed. • Investigate the potential of much lighter portable real-time instrument. • Improvements to existing instruments are suggested to improve their design. • Boron-Doped liquid scintillator design is the most promising, but needs further work

  14. Portable radiation meters developed in Boris Kidric Institute

    International Nuclear Information System (INIS)

    Sobajic, V.; Smelcerovic, M.

    1989-01-01

    Portable meters designed for X and gamma radiation measurements and beta detection are described. An instrument using ionization chamber is developed with new type of electrometer amplifier. It is designed for precise and reliable exposure and exposure rate measurements. Another instrument with GM counters covers 8 linear ranges: from background up to 10 Sv/h. Some specific solutions and basic measurement characteristics of these instruments are presented (author)

  15. Ambiguity effects of rhyme and meter.

    Science.gov (United States)

    Wallot, Sebastian; Menninghaus, Winfried

    2018-04-23

    Previous research has shown that rhyme and meter-although enhancing prosodic processing ease and memorability-also tend to make semantic processing more demanding. Using a set of rhymed and metered proverbs, as well as nonrhymed and nonmetered versions of these proverbs, the present study reveals this hitherto unspecified difficulty of comprehension to be specifically driven by perceived ambiguity. Roman Jakobson was the 1st to propose this hypothesis, in 1960. He suggested that "ambiguity is an intrinsic, inalienable feature" of "parallelistic" diction of which the combination of rhyme and meter is a pronounced example. Our results show that ambiguity indeed explains a substantial portion of the rhyme- and meter-driven difficulty of comprehension. Longer word-reading times differentially reflected ratings for ambiguity and comprehension difficulty. However, the ambiguity effect is not "inalienable." Rather, many rhymed and metered sentences turned out to be low in ambiguity. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  16. 39 CFR 501.15 - Computerized Meter Resetting System.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at...

  17. A Probabilistic Model of Meter Perception: Simulating Enculturation

    Directory of Open Access Journals (Sweden)

    Bastiaan van der Weij

    2017-05-01

    Full Text Available Enculturation is known to shape the perception of meter in music but this is not explicitly accounted for by current cognitive models of meter perception. We hypothesize that the induction of meter is a result of predictive coding: interpreting onsets in a rhythm relative to a periodic meter facilitates prediction of future onsets. Such prediction, we hypothesize, is based on previous exposure to rhythms. As such, predictive coding provides a possible explanation for the way meter perception is shaped by the cultural environment. Based on this hypothesis, we present a probabilistic model of meter perception that uses statistical properties of the relation between rhythm and meter to infer meter from quantized rhythms. We show that our model can successfully predict annotated time signatures from quantized rhythmic patterns derived from folk melodies. Furthermore, we show that by inferring meter, our model improves prediction of the onsets of future events compared to a similar probabilistic model that does not infer meter. Finally, as a proof of concept, we demonstrate how our model can be used in a simulation of enculturation. From the results of this simulation, we derive a class of rhythms that are likely to be interpreted differently by enculturated listeners with different histories of exposure to rhythms.

  18. Improving the performances of H-Darrieus cross-flow turbines through proper detached end plate designs

    Science.gov (United States)

    Villeneuve, Thierry; Boudreau, Matthieu; Dumas, Guy; CFD Laboratory LMFN Team

    2017-11-01

    Previous studies on H-Darrieus cross-flow turbines have highlighted the fact that their performances are highly sensitive to the detrimental effects associated with the blades tips. Wingtip devices could be designed in order to attenuate these effects, but the benefits of such devices are always impaired by their added viscous drag since they are moving with the turbine's blades. In this context, the development of fixed and detached end plates, i.e., which are not in contact with the turbine's blades, could reduce the tip losses without the undesirable added drag of typical wingtip devices moving with the blades. The case of a single stationary blade with detached end plates has first been investigated with RANS simulations in order to understand the mechanisms responsible for the increase of the blade's lift. An analysis of the vorticity lines' dynamics provides crucial insights into the effects of the gap width between the blade and the detached end plate on the blade's loading and on the intensity of the tip vortices. Based on these observations, various configurations of detached end plates are tested on cross-flow turbines via RANS and DDES simulations. Preliminary results show that appropriate detached end plates can significantly increase the turbines' efficiency. The authors gratefully acknowledge the Natural Sciences and Engineering Research Council of Canada (NSERC) for their financial support as well as Compute Canada and Calcul Québec for their supercomputer allocations.

  19. The Gemini 8-Meter Telescopes Project

    Science.gov (United States)

    Boroson, Todd A.

    1995-05-01

    The Gemini 8-Meter Telescopes Project is an international partnership to build and operate two 8-meter telescopes, one on Mauna Kea, Hawaii, and one on Cerro Pachon, Chile. The telescopes will be international facilities, open to the scientific communities of the six member countries, the United States (50%), the United Kingdom (25%), Canada (15%), Chile (5%), Argentina (2.5%), and Brazil (2.5%). The telescopes are designed to exploit the best atmospheric conditions at these excellent sites. Near diffraction limited performance will be delivered at 2.2 microns and longward, with minimal degradation of the best seeing conditions at shorter wavelengths. The telescopes and facilities are designed to achieve emissivity opportunity. First light for the Mauna Kea telescope is expected in late 1998, and for the Cerro Pachon telescope in mid-2000. This talk will report on construction progress, the instrumental capabilities, and operations strategies being considered. The Gemini 8-meter Telescopes Project is managed by the Association of Universities for Research in Astronomy (AURA), Inc. under a cooperative agreement with the National Science Foundation which serves as executive agency for the Gemini partner countries. U.S. participation in the project is through the U.S. Gemini Program, a division of the National Optical Astronomy Observatories. NOAO is operated by AURA, Inc. under cooperative agreement with the National Science Foundation.

  20. Density meters utilizing ionizing radiation: definitions and test methods

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This standard is applicable to density meters utilizing ionizing radiation, designed for the measurement of the density of liquids, slurries or fluidized solids. The standard applies to transmission-type instruments only. Reference to compliance with this standard shall identify any deviations and the reasons for such deviations. Safety aspects are not included but should fulfill the requirements of all relevant internationally accepted standards

  1. Charge Meter

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 19; Issue 4. Charge Meter: Easy Way to Measure Charge and Capacitance: Some Interesting Electrostatic Experiments. M K Raghavendra V Venkataraman. Classroom Volume 19 Issue 4 April 2014 pp 376-390 ...

  2. A Probabilistic Model of Meter Perception: Simulating Enculturation

    NARCIS (Netherlands)

    van der Weij, B.; Pearce, M.T.; Honing, H.

    Enculturation is known to shape the perception of meter in music but this is not explicitly accounted for by current cognitive models of meter perception. We hypothesize that the induction of meter is a result of predictive coding: interpreting onsets in a rhythm relative to a periodic meter

  3. Measuring methods in power metering 2013; Elektrizitaetsmesstechnik 2013

    Energy Technology Data Exchange (ETDEWEB)

    Kahmann, Martin; Zayer, Peter (eds.)

    2012-07-01

    The book addresses technical and economic issues of power metering, data communication and data processing. Smart metering is the key issue discussed in all 14 contributions: 1. The perspective of Smart Metering in Europe through 2020; 2. Introduction of Smart Metering in Austria; 3. Metering after the amended EnWG 2011; 4. The FNN project ''MessSystem 2020''; 5. Technological requirements of Smart Grid and Smart Market; 6. DIN Spec 33440 ''Ergonomic Aspects of Smart Grids and Electromobility''; 7. Load management as a key element of energy transition; 8. Added value in Smart Metering as a result of Smart Home applications, 9. The main cost factors of the new metering systems; 10. BSI protection profile: Smart Meter Gateway certification; 11. The influence of new boundary conditions in metering on intercompany processes; 12. Reliable time allotment via internet; 13. Recommendations of the EEG Clearing Authority on metering problems; 14. Outline quality management manual for state-authorized test services for electric power, gas, water, and heat. [German] Dieses Buch richtet seinen Blick sowohl auf technische wie auch auf energiewirtschaftliche Themen rund um das Thema Mess- und Zaehltechnik sowie die inzwischen immer bedeutsamer werdende zugehoerige Datenkommunikations- und Datenverarbeitungstechnik. Eine zunehmende Betrachtung des Smart Metering als einen Teilaspekt des grossen Themas Smart Grid bildet die gemeinsame Klammer um die Beitraege. Die Themen der 14 Beitraege sind: 1. Perspektive Smart Metering in Europa bis 2020; 2. Smart-Meter-Einfuehrung in Oesterreich; 3. Das Messwesen nach der EnWG-Novelle 2011; 4. Das FNN-Projekt ''MessSystem 2020''; 5. Anforderungen durch Smart Grid und Smart Market an die intelligente Messtechnik; 6. DIN Spec 33440 ''Ergonomie-Aspekte zu Smart Grid und Elektromobilitaet''; 7. Lastverschiebung als Baustein der Energiewende; 8. Mehrwerte beim Smart

  4. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters.

    Science.gov (United States)

    Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B

    2013-11-01

    Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and

  5. Critical review of directional neutron survey meters

    Science.gov (United States)

    Balmer, Matthew J. I.; Gamage, Kelum A. A.; Taylor, Graeme C.

    2014-01-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument.

  6. Critical Review of Directional Neutron Survey Meters

    International Nuclear Information System (INIS)

    Balmer, M.J.I.; Gamage, K.A.A.; Taylor, G.C.

    2013-06-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument. (authors)

  7. 24 CFR 965.401 - Individually metered utilities.

    Science.gov (United States)

    2010-04-01

    ... URBAN DEVELOPMENT PHA-OWNED OR LEASED PROJECTS-GENERAL PROVISIONS Individual Metering of Utilities for Existing PHA-Owned Projects § 965.401 Individually metered utilities. (a) All utility service shall be... supplier or through the use of checkmeters, unless: (1) Individual metering is impractical, such as in the...

  8. Evaluation of uncertainties in the calibration of radiation survey meter

    International Nuclear Information System (INIS)

    Potiens, M.P.A.; Santos, G.P.

    2006-01-01

    In order to meet the requirements of ISO 17025, the quantification of the expanded uncertainties of experimental data in the calibration of survey meters must be carried out using well defined concepts, like those expressed in the 'ISO-Guide to the Expression of Uncertainty in Measurement'. The calibration procedure of gamma ray survey meters involves two values that have to get their uncertainties clearly known: measurements of the instrument under calibration and the conventional true values of a quantity. Considering the continuous improvement of the calibration methods and set-ups, it is necessary to evaluate periodically the involved uncertainties in the procedures. In this work it is shown how the measurement uncertainties of an individual calibration can be estimated and how it can be generalized to be valid for others radiation survey meters. (authors)

  9. Metering error quantification under voltage and current waveform distortion

    Science.gov (United States)

    Wang, Tao; Wang, Jia; Xie, Zhi; Zhang, Ran

    2017-09-01

    With integration of more and more renewable energies and distortion loads into power grid, the voltage and current waveform distortion results in metering error in the smart meters. Because of the negative effects on the metering accuracy and fairness, it is an important subject to study energy metering combined error. In this paper, after the comparing between metering theoretical value and real recorded value under different meter modes for linear and nonlinear loads, a quantification method of metering mode error is proposed under waveform distortion. Based on the metering and time-division multiplier principles, a quantification method of metering accuracy error is proposed also. Analyzing the mode error and accuracy error, a comprehensive error analysis method is presented which is suitable for new energy and nonlinear loads. The proposed method has been proved by simulation.

  10. Performance of Combined Water Turbine with Semielliptic Section of the Savonius Rotor

    OpenAIRE

    Sahim, Kaprawi; Santoso, Dyos; Radentan, Agus

    2013-01-01

    The Darrieus turbine is a suitable power generation in free stream flow because it is simple in construction, but it has the disadvantage of its small starting torque. The Savonius turbine has a high starting torque but the efficiency is smaller than that of Darrieus turbine. To improve the starting torque of Darrieus turbine, the Savonius buckets are introduced into the Darrieus turbine and the combined turbine is called Darrieus-Savonius turbine. In this study, three semielliptic sections o...

  11. Accuracy Improvement of Boron Meter Adopting New Fitting Function and Multi-Detector

    Directory of Open Access Journals (Sweden)

    Chidong Kong

    2016-12-01

    Full Text Available This paper introduces a boron meter with improved accuracy compared with other commercially available boron meters. Its design includes a new fitting function and a multi-detector. In pressurized water reactors (PWRs in Korea, many boron meters have been used to continuously monitor boron concentration in reactor coolant. However, it is difficult to use the boron meters in practice because the measurement uncertainty is high. For this reason, there has been a strong demand for improvement in their accuracy. In this work, a boron meter evaluation model was developed, and two approaches were considered to improve the boron meter accuracy: the first approach uses a new fitting function and the second approach uses a multi-detector. With the new fitting function, the boron concentration error was decreased from 3.30 ppm to 0.73 ppm. With the multi-detector, the count signals were contaminated with noise such as field measurement data, and analyses were repeated 1,000 times to obtain average and standard deviations of the boron concentration errors. Finally, using the new fitting formulation and multi-detector together, the average error was decreased from 5.95 ppm to 1.83 ppm and its standard deviation was decreased from 0.64 ppm to 0.26 ppm. This result represents a great improvement of the boron meter accuracy.

  12. Accuracy improvement of boron meter adopting new fitting function and multi-detector

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Chidong; Lee, Hyun Suk; Tak, Tae Woo; Lee, Deok Jung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of); KIm, Si Hwan; Lyou, Seok Jean [Users Incorporated Company, Hansin S-MECA, Daejeon (Korea, Republic of)

    2016-12-15

    This paper introduces a boron meter with improved accuracy compared with other commercially available boron meters. Its design includes a new fitting function and a multi-detector. In pressurized water reactors (PWRs) in Korea, many boron meters have been used to continuously monitor boron concentration in reactor coolant. However, it is difficult to use the boron meters in practice because the measurement uncertainty is high. For this reason, there has been a strong demand for improvement in their accuracy. In this work, a boron meter evaluation model was developed, and two approaches were considered to improve the boron meter accuracy: the first approach uses a new fitting function and the second approach uses a multi-detector. With the new fitting function, the boron concentration error was decreased from 3.30 ppm to 0.73 ppm. With the multi-detector, the count signals were contaminated with noise such as field measurement data, and analyses were repeated 1,000 times to obtain average and standard deviations of the boron concentration errors. Finally, using the new fitting formulation and multi-detector together, the average error was decreased from 5.95 ppm to 1.83 ppm and its standard deviation was decreased from 0.64 ppm to 0.26 ppm. This result represents a great improvement of the boron meter accuracy.

  13. Relation between size of contrast meter and radiographic density difference for radiographic test aluminium welds

    International Nuclear Information System (INIS)

    Senda, Tomio; Hirayama, Kazuo; Masaoka, Naotoshi; Fujita, Minoru.

    1977-01-01

    The influence of contrast meter with difference surface area (5.0 mm x 5.0 mm, 10.0 mm x 10.0 mm, 15.0 mm x 15.0 mm, 30.0 mm x 30.0 mm) and separated type on radiographic density difference (Δ D) were investigated for radiographic test of aluminum welds. It was found that the effect of scattered radiation on contrast meter represented highest at test specimen thickness of 20 mm, and Δ D was constant as the size was increased from 10.0 mm x 10.0 mm to 15.0 mm x 15.0 mm for aluminum contrast meter. For this reason, a proposal of the contrast meter with 10.0 mm x 10.0 mm (surface area) has made to replace (15.0 mm x 15 mm) at amendment of JIS Z 3105. (auth.)

  14. FibroMeters: a family of blood tests for liver fibrosis.

    Science.gov (United States)

    Calès, P; Boursier, J; Oberti, F; Hubert, I; Gallois, Y; Rousselet, M-C; Dib, N; Moal, V; Macchi, L; Chevailler, A; Michalak, S; Hunault, G; Chaigneau, J; Sawadogo, A; Lunel, F

    2008-09-01

    FibroMeters are blood tests for liver fibrosis with several specificities: two main diagnostic targets (fibrosis stage and area of fibrosis); adaptation to specific causes; and results confirmed by an expert system. Thus, FibroMeters comprise six different tests: one for staging and one for quantitation of liver fibrosis in each of the three main causes of chronic liver disease-chronic viral hepatitis, alcoholic liver disease (ALD) and non-alcoholic fatty liver disease (NAFLD). FibroMeters display a high overall diagnostic accuracy and are the only tests to correctly classify 100% of HCV patients without fibrosis or with cirrhosis. They have 90% predictive values in a higher proportion of patients than with other usual blood tests. A 90% correct classification is available in 100% of HCV patients with the following reliable diagnostic intervals: F0/1, F1/2, F2+/-1, F3+/-1. In real-life conditions, the reproducibility of FibroMeters is higher than that of liver biopsy or ultrasonographic elastometry. FibroMeters are robust tests with the most stable diagnostic performance across different centers. Optional tests are also available, such as a specific one for cirrhosis, which has a diagnostic accuracy of 93.0% (AUROC: 0.92) and a 100% positive predictive value for diagnosis of HCV cirrhosis. Determination by FibroMeters of the area of fibrosis - the only direct, non-invasive, quantitative measurement of liver fibrosis - are especially useful for following-up cirrhosis as it correlates well with clinical events. FibroMeters are also very accurate in HVB or HIV-HCV co-infected patients. The tests specific for ALD and NAFLD also have a high diagnostic accuracy (AUROCs: 0.96 and 0.94, respectively, for significant fibrosis).

  15. Educational Electrical Appliance Power Meter and Logger

    Science.gov (United States)

    Nunn, John

    2013-01-01

    The principles behind two different designs of inductive power meter are presented. They both make use of the microphone input of a computer which, together with a custom-written program, can record the instantaneous power of a domestic electrical appliance. The device can be built quickly and can be calibrated with reference to a known power…

  16. Evaluation of a new portable glucose meter designed for the use in cats.

    Science.gov (United States)

    Zini, E; Moretti, S; Tschuor, F; Reusch, C E

    2009-09-01

    Portable blood glucose meters (PBGMs) are useful in the management of diabetes mellitus in cats. In the present study we compared the performance of two PBGMs: the AlphaTRAK (Abbott Animal Health, Maidenhead, England) specifically developed for dogs and cats, and the Ascensia ELITE (Bayer HealthCare, Zurich, Switzerland) developed for humans. Quality parameters, including precision and accuracy, were better for the AlphaTRAK meter compared to Ascensia ELITE. While the AlphaTRAK meter results did not differ from the reference method, results from the Ascensia ELITE were significantly (Pblood glucose levels in cats.

  17. Smart Metering System for Microgrids

    DEFF Research Database (Denmark)

    Palacios-Garcia, Emilio; Guan, Yajuan; Savaghebi, Mehdi

    2015-01-01

    suppliers, but they can also play a big role in the control of the Microgrid since the recorded power and energy profiles can be integrated in energy management systems (EMS). In addition, basic power quality (PQ) disturbance can de detected and reported by some advanced metering systems. Thus, this paper...... will expose an example of Smart Meters integration in a Microgrid scenario, which is the Intelligent Microgrid Lab of Aalborg University (AAU). To do this, first the installation available in the Microgrid Lab will be introduced. Then, three different test scenarios and their respective results...... will be presented, regarding the capabilities of this system and the advantages of integration the Smart Meters information in the Microgrid control....

  18. Low Cost Digital Vibration Meter.

    Science.gov (United States)

    Payne, W Vance; Geist, Jon

    2007-01-01

    This report describes the development of a low cost, digital Micro Electro Mechanical System (MEMS) vibration meter that reports an approximation to the RMS acceleration of the vibration to which the vibration meter is subjected. The major mechanical element of this vibration meter is a cantilever beam, which is on the order of 500 µm in length, with a piezoresistor deposited at its base. Vibration of the device in the plane perpendicular to the cantilever beam causes it to bend, which produces a measurable change in the resistance of a piezoresistor. These changes in resistance along with a unique signal-processing scheme are used to determine an approximation to the RMS acceleration sensed by the device.

  19. Handheld Multi-Gas Meters Assessment Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-27

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the monitored chemical. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. In April 2016 the System Assessment and Validation for Emergency Responders (SAVER) Program conducted an operationally-oriented assessment of MGMs. Five MGMs were assessed by emergency responders. The criteria and scenarios used in this assessment were derived from the results of a focus group of emergency responders with experience in using MGMs. The assessment addressed 16 evaluation criteria in four SAVER categories: Usability, Capability, Maintainability, and Deployability.

  20. Robust Meter Network for Water Distribution Pipe Burst Detection

    OpenAIRE

    Donghwi Jung; Joong Hoon Kim

    2017-01-01

    A meter network is a set of meters installed throughout a water distribution system to measure system variables, such as the pipe flow rate and pressure. In the current hyper-connected world, meter networks are being exposed to meter failure conditions, such as malfunction of the meter’s physical system and communication system failure. Therefore, a meter network’s robustness should be secured for reliable provision of informative meter data. This paper introduces a multi-objective optimal me...

  1. Versatile operation meter for nuclear information

    International Nuclear Information System (INIS)

    Huang Yong; Xiao Yabin; Wang Shuyuan; Shu Jingfang; Di Shaoliang; Wu Hongbin

    1995-01-01

    This paper states a low-cost, small-volume, multi-function, reproducible and new model intelligent nuclear electronic meter. It's hardware and Software were detailed and the 137 Cs spectrum with this meter was presented

  2. Smart metering - new possibilities for energy distribution in the mass customer sector; Smart Metering - neue Moeglichkeiten fuer den Energievertrieb im Massenkundenbereich

    Energy Technology Data Exchange (ETDEWEB)

    Haller, T. [Simon-Kucher aand Partners GmbH, Wien (Austria); Hoffmann, S.O.; Rentschler, M.D. [Simon-Kucher and Partners Strategy and Marketing Consultants GmbH, Bonn (Germany)

    2008-06-15

    As a result of the liberalisation of gas and electricity metering procedures energy suppliers are more and more turning their attention to innovative and intelligent metering techniques. Smart Metering allows energy suppliers to improve their metering processes while at the same time responding better to their customers' needs. These developments are also opening up new sales opportunities because intelligent meters facilitate the launch of new products in the mass customer sector. There is therefore much in favour of looking at this topic in greater detail.

  3. Effects of simulated altitude on blood glucose meter performance: implications for in-flight blood glucose monitoring.

    Science.gov (United States)

    Olateju, Tolu; Begley, Joseph; Flanagan, Daniel; Kerr, David

    2012-07-01

    Most manufacturers of blood glucose monitoring equipment do not give advice regarding the use of their meters and strips onboard aircraft, and some airlines have blood glucose testing equipment in the aircraft cabin medical bag. Previous studies using older blood glucose meters (BGMs) have shown conflicting results on the performance of both glucose oxidase (GOX)- and glucose dehydrogenase (GDH)-based meters at high altitude. The aim of our study was to evaluate the performance of four new-generation BGMs at sea level and at a simulated altitude equivalent to that used in the cabin of commercial aircrafts. Blood glucose measurements obtained by two GDH and two GOX BGMs at sea level and simulated altitude of 8000 feet in a hypobaric chamber were compared with measurements obtained using a YSI 2300 blood glucose analyzer as a reference method. Spiked venous blood samples of three different glucose levels were used. The accuracy of each meter was determined by calculating percentage error of each meter compared with the YSI reference and was also assessed against standard International Organization for Standardization (ISO) criteria. Clinical accuracy was evaluated using the consensus error grid method. The percentage (standard deviation) error for GDH meters at sea level and altitude was 13.36% (8.83%; for meter 1) and 12.97% (8.03%; for meter 2) with p = .784, and for GOX meters was 5.88% (7.35%; for meter 3) and 7.38% (6.20%; for meter 4) with p = .187. There was variation in the number of time individual meters met the standard ISO criteria ranging from 72-100%. Results from all four meters at both sea level and simulated altitude fell within zones A and B of the consensus error grid, using YSI as the reference. Overall, at simulated altitude, no differences were observed between the performance of GDH and GOX meters. Overestimation of blood glucose concentration was seen among individual meters evaluated, but none of the results obtained would have resulted in

  4. Proceedings of the 2006 smart metering conference and expo

    International Nuclear Information System (INIS)

    2006-01-01

    Ontario's smart metering program was launched as part of a general demand response management strategy to improve energy conservation in the province. Smart metering will help consumers to control their electricity bills through conservation and demand response, and will allow consumers to better manage their energy consumption and use it more effectively during cheaper, off-peak times of day. Smart metering systems measure how much electricity a customer uses on an hourly basis, and data is transferred daily to local electricity distributors. Toronto Hydro will have close to 200,000 smart meters installed by the end of 2006. By 2010, Toronto will be North America's largest urban centre to have made the full transition to smart metering technology across its entire base. This conference provided an update of Toronto Hydro's smart metering project, as well as details of their demand response program. Presentations were given by a variety of experts in information technology as well as electric power industry leaders North American demand and response metering strategies were reviewed, as well as various initiatives in advanced metering infrastructure (AMI). Security risks associated with smart metering environments were reviewed. An evaluation of the current regulatory environment was presented along with a discussion of smart metering standards and compatibility issues. New metering technologies were presented as well as various associated demand side management tools. Smart metering pilot programs and initiatives were discussed, and best practices in smart metering were evaluated. Twenty-nine presentations were given at the conference, 13 of which have been indexed separately for inclusion in this database. refs., tabs., figs

  5. Arduino based radiation survey meter

    International Nuclear Information System (INIS)

    Rahman, Nur Aira Abd; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee; Muzakkir, Amir

    2016-01-01

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr −1 ). Conversion factor (CF) value for conversion of CPM to μSvhr −1 determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr

  6. Energy metering, management and accounting; Comptage, gestion, et comptabilite de l`energie

    Energy Technology Data Exchange (ETDEWEB)

    Foucherand, P. [Agence de l`environnement et de la maitrise de l`energie, Rhone-Alpes (France)

    1996-12-31

    The activities of the French Energy Conservation Agency (ADEME) in the field of energy management and conservation through energy metering in industrial plants, and more especially in mechanical and metal industries, are presented. Audit and diagnostic procedures and information/awareness measures are presented and discussed with the example of a regional program, and two operations conducted in a mechanical industrial plant and a foundry where metering systems were installed

  7. A Framework for Reliable Reception of Wireless Metering Data using Protocol Side Information

    DEFF Research Database (Denmark)

    Melchior Jacobsen, Rasmus; Popovski, Petar

    2013-01-01

    the deterministic protocol structure to obtain side information and group the packets from the same meter. We derive the probability of falsely pairing packets from different senders in the simple case of no channel errors, and show through simulation and data from an experimental deployment the probability...... of false pairing with channel errors. The pairing is an essential step towards recovery of metering data from as many as possible meters under harsh channel conditions. From the experiment we find that more than 15% of all conducted pairings are between two erroneous packets, which sets an upper bound...

  8. Inadequate peak expiratory flow meter characteristics detected by a computerised explosive decompression device

    DEFF Research Database (Denmark)

    Miller, M.R.; Atkins, P.R.; Pedersen, O.F.

    2003-01-01

    Methods: The dynamic response of mini-Wright (MW), Vitalograph (V), TruZone (TZ), MultiSpiro (MS) and pneumotachograph (PT) flow meters was tested by delivering two differently shaped flow-time profiles from a computer controlled explosive decompression device fitted with a fast response solenoid.......1) and 257 (39.2), respectively, and at ≈200 l/min they were 51 (23.9) and 1 (0.5). All the meters met ATS accuracy requirements when tested with their waveforms. Conclusions: An improved method for testing the dynamic response of flow meters detects marked overshoot (underdamping) of TZ and MS responses...

  9. Automatic ranging circuit for a digital panel meter

    International Nuclear Information System (INIS)

    Mueller, T.R.; Ross, H.H.

    1976-01-01

    This invention relates to a range changing circuit that operates in conjunction with a digital panel meter of fixed sensitivity. The circuit decodes the output of the panel meter and uses that information to change the gain of an input amplifier to the panel meter in order to ensure that the maximum number of significant figures is always displayed in the meter. The circuit monitors five conditions in the meter and responds to any of four combinations of these conditions by means of logic elements to carry out the function of the circuit. The system was designed for readout of a fluorescence analyzer for uranium analysis

  10. EU data protection and smart metering. Legal boundary conditions; EU-Datenschutz und Smart Metering. Rechtliche Rahmenbedingungen

    Energy Technology Data Exchange (ETDEWEB)

    Hladjk, Joerg [Praxisgruppe European Data Protection and Privacy, Hunton and Williams, Bruessel (Belgium)

    2011-07-01

    With the introduction of smart metering, the problem of data protection arises. The independent Article 29 Data Protection Group of the European Commission drew up an expert opinion with the intention of explaining the applicable EU data protection regulations for the smart metering technology in the power supply sector. (orig.)

  11. Chapter 9: Metering Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy-Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Mort, Dan [ADM Associates, Inc. Sacramento, CA (United States)

    2017-09-01

    Estimated energy savings are calculated as the difference between the energy use during the baseline period and the energy use during the post installation period of the EEM. This chapter describes the physical properties measured in the process of evaluating EEMs and the specific metering methods for several types of measurements. Skill-level requirements and other operating considerations are discussed, including where, when, and how often measurements should be made. The subsequent section identifies metering equipment types and their respective measurement accuracies. This is followed by sections containing suggestions regarding proper data handling procedures and the categorization and definition of several load types.

  12. Your Glucose Meter

    Science.gov (United States)

    ... Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco ... 164KB) En Español Basic Facts 7 Tips for Testing Your Blood Sugar and Caring for Your Meter ...

  13. Arduino based radiation survey meter

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Nur Aira Abd, E-mail: nur-aira@nm.gov.my; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee [Malaysian Nuclear Agency, 43000, Bangi, Selangor (Malaysia); Muzakkir, Amir [Sinaran Utama Teknologi Sdn Bhd, 43650, Bandar Baru Bangi, Selangor (Malaysia)

    2016-01-22

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr{sup −1}). Conversion factor (CF) value for conversion of CPM to μSvhr{sup −1} determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr.

  14. How today's USM diagnostics solve metering problems[Ultrasonic meters

    Energy Technology Data Exchange (ETDEWEB)

    Lansing, John

    2005-07-01

    This paper discusses both basic and advanced diagnostic features of gas ultrasonic meters (USM), and how capabilities built into today's electronics can identify problems that often may not have been identified in the past. It primarily discusses fiscal-quality, multi-path USMs and does not cover issues that may be different with non-fiscal meters. Although USMs basically work the same, the diagnostics for each manufacturer does vary. All brands provide basic features as discussed in AGA 9. However, some provide advanced features that can be used to help identify issues such as blocked flow conditioners and gas compositional errors. This paper is based upon the Daniel USM design and the information presented here may or may not be applicable to other manufacturers. (author) (tk)

  15. Information security of remote-reading energy meters

    International Nuclear Information System (INIS)

    Jacobson, J.

    1994-01-01

    This report presents basic concepts within the field of IT security. The ITSEC security and the ITSEM methods given by the European Community are used as a base. The EC INFOSEC research programme has included the project 'PER DOMUM' which focuses on remote reading of energy meters. The project is a co-operation between TACS (U.K.), GPP (Germany), CESI (Italy) and ENEL (Italy). SP has during the spring and summer of 1994 participated in the concluding of the project. Threats, security functions and security mechanisms are given for remote reading of energy meters. All of the listed functions and mechanisms do not origin from the 'PER DOMUM' project, but are the experiences of SP. The security evaluation is explained in two ways. One description of the required by ITSEM is given. Another description is given of which deliverables are required to perform the evaluation

  16. De Minimis Thresholds for Federal Building Metering Appropriateness

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, Jordan W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-31

    The U.S. Department of Energy (DOE) is required by statute and Presidential Memorandum to establish guidelines for agencies to meter their Federal buildings for energy (electricity, natural gas, and steam) and water. See 42 U.S.C. § 8253(e). DOE issued guidance in February 2006 on the installation of electric meters in Federal buildings. A recent update to the 2006 guidance accounts for more current metering practices within the Federal Government. The updated metering guidance specifies that all Federal buildings shall be considered “appropriate” for energy or water metering unless identified for potential exclusion. In developing the updated guidance to carry out the statue, Congress also directed DOE to (among other things) establish exclusions from the metering requirements based on the de minimis quantity of energy use of a Federal building, industrial process, or structure. This paper discusses the method used to identify de minimis values.

  17. Water metering in England and Wales

    Directory of Open Access Journals (Sweden)

    David Zetland

    2016-02-01

    Full Text Available The transformation of water services that began with the privatisation of water companies in 1989 extended to households with the implementation of water metering. Meters 'privatised' water and the cost of provision by allocating to individual households costs that had previously been shared within the community. This (ongoing conversion of common pool to private good has mostly improved economic, environmental and social impacts, but the potential burden of metering on poorer households has slowed the transition. Stronger anti-poverty programmes would be better at addressing this poverty barrier than existing coping mechanisms reliant on subsidies from other water consumers.

  18. 18 CFR 367.9020 - Account 902, Meter reading expenses.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Account 902, Meter... GAS ACT Operation and Maintenance Expense Chart of Accounts § 367.9020 Account 902, Meter reading... customer meters, and determining consumption when performed by employees engaged in reading meters. (b...

  19. Smart Metering. Between technical challenge and societal acceptance - Interdisciplinary status quo; Smart Metering. Zwischen technischer Herausforderung und gesellschaftlicher Akzeptanz - Interdisziplinaerer Status Quo

    Energy Technology Data Exchange (ETDEWEB)

    Westermann, Dirk; Doering, Nicola; Bretschneider, Peter (eds.)

    2013-04-01

    The international research project RESIDENS (more efficient energy utilization by means of system technical integration of the private ultimate consumer) investigates the technology of smart metering that is the utilization of intelligent smart meters in private households. The interdisciplinary character of the RESIDENS project becomes visible by different sub-projects examining different formulations of a question from perspectives of different scientific disciplines: First of all, chapter 2 of the contribution under consideration follows up the question, what impact the media coverage on smart metering has on the perception of this technology in the population at large. Chapter 3 reports on the state of the art of the smart metering. Chapter 4 illustrates how a load control of private consumers can be performed by means of the smart meter technology. Chapter 5 reports on the impacts of the smart metering on the procurement of energy in the liberalised energy market. Chapter 6 investigates the smart metering from the customer's point of view. Concretely, the user-friendliness of an internet portal is evaluated by which the customers may follow up their consumption of electricity by means of an intelligent smart meter continuously. Chapter 7 illustrates legal aspects of smart metering from the perspective of the customer, electricity suppliers and distribution system operators. Chapter 8 presents the conception and implementation of an online gaming operation for the promotion of competency of private power customers: In line with this game, the participants may learn to handle smart metering and flexible electricity tariffs in an entertaining manner. Finally, chapter 9 reports on an expert interview in which the smart metering technology is evaluated by public utilities being involved in this project.

  20. Multiphase flow metering: 4 years on

    Energy Technology Data Exchange (ETDEWEB)

    Falcone, G.; Hewitt, G.F.; Alimonti, C.; Harrison, B.

    2005-07-01

    Since the authors' last review in 2001 [1], the use of Multiphase Flow Metering (MFM) within the oil and gas industry continues to grow apace, being more popular in some parts of the world than others. Since the early 1990's, when the first commercial meters started to appear, there have been more than 1,600 field applications of MFM for field allocation, production optimisation and mobile well testing. As the authors predicted, wet gas metering technology has improved to such an extent that its use has rapidly increased worldwide. A ''who's who'' of the MFM sector is provided, which highlights the mergers in the sector and gives an insight into the meters and measurement principles available today. Cost estimates, potential benefits and reliability in the field of the current MFM technologies are revisited and brought up to date. Several measurements technologies have resurfaced, such as passive acoustic energy patterns, infrared wavelengths, Nuclear Magnetic Resonance (NMR) and Electrical Capacitance Tomography (ECT), and they are becoming commercial. The concept of ''virtual metering'', integrated with ''classical MFM'', is now widely accepted. However, sometimes the principles of the MFM measurements themselves are forgotten, submerged in the sales and marketing hype. (author) (tk)

  1. Manage costs and revenues by achieving continuous measurement certainty with the Auto-Adjust Turbo Meter; Gerez les couts et les recettes en acquerant une certitude continuelle de mesure grace au Auto-Adjust Turbo Meter

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, D. [Invensys Energy Metering, Pennsylvania (United States)

    2000-07-01

    Uncertainty in flow measurement and its consequent ramifications are accepted as normal costs of transporting and distributing natural gas. However, a notable advancement in turbine meter technology, pioneered by Invensys Energy Metering, uses two rotors in a tandem configuration to offer unique capabilities beyond those of the tried-and-proven, single-rotor turbine. A flow meter, which monitors its own performance and adjusts its measurement, on a real-time basis, for any deviations from its initial calibration, could largely eliminate many of the costs and lost revenue associated with flow metering and measurement uncertainty. The dual-rotor turbine, trade named the Auto-Adjust Turbo Meter (AAT), is such a flow meter; it provides Continuous Measurement Certainty, with the accompanying potential for enhanced management of costs and revenues. Proprietary algorithms in the AAT's secondary electronics correlate the velocities of the main rotor and the downstream sensing rotor, over the full range of the meter's rated capacity and pressure, such that a real-time adjustment to the indicated volume corrects it to the actual volume. Improved gas accountability results, and substantial savings related to meter site visits, meter testing and repair, preventive maintenance programs, and measurement disputes can be realized. Test data and case histories from a broad range of end users are related to demonstrate areas of potential savings and revenue recovery. (author)

  2. Experiment of aerosol-release time for a novel automatic metered dose inhaler

    Directory of Open Access Journals (Sweden)

    Mingrong Zhang

    2016-05-01

    Full Text Available The objective of this study was to evaluate the aerosol-release time in the development of a new automatic adapter for metered dose inhaler. With this device, regular manually operated metered dose inhalers become automatic. During the study, an inhalation simulator was designed and tested with the newly developed mechatronic system. By adjusting the volume and the pressure of the vacuum tank, most human inhalation waveforms were able to simulate. As an example, regular quick-deep and slow-deep waveforms were matched within reasonable accuracy. Finally, with the help of dynamic image processing, the aerosol-release time (Tr was carefully measured and fully discussed, including the switch-on time (Ts, the mechatronics-hysteresis (Tm and the intentional-delay (Ti. Under slow-deep inhalation condition which is suitable for metered dose inhaler medicine delivery, the switch-on flow-rate could reach as low as 10 L/min, and the corresponding switch-on time was approximately 0.20 s. While the mechatronics-hysteresis depended on the brand of metered dose inhaler, assuming there was no intentional-delay, the aerosol-release time could be as low as 0.40 and 0.60 s, respectively, for two commercially available metered dose inhalers studied in this article. Therefore, this newly developed mechatronic adapter system could ensure aerosol-release time (Tr within satisfactory range for metered dose inhalers.

  3. Multi-Antenna Data Collector for Smart Metering Networks with Integrated Source Separation by Spatial Filtering

    Science.gov (United States)

    Quednau, Philipp; Trommer, Ralph; Schmidt, Lorenz-Peter

    2016-03-01

    Wireless transmission systems in smart metering networks share the advantage of lower installation costs due to the expandability of separate infrastructure but suffer from transmission problems. In this paper the issue of interference of wireless transmitted smart meter data with third party systems and data from other meters is investigated and an approach for solving the problem is presented. A multi-channel wireless m-bus receiver was developed to separate the desired data from unwanted interferers by spatial filtering. The according algorithms are presented and the influence of different antenna types on the spatial filtering is investigated. The performance of the spatial filtering is evaluated by extensive measurements in a realistic surrounding with several hundreds of active wireless m-bus transponders. These measurements correspond to the future environment for data-collectors as they took place in rural and urban areas with smart gas meters equipped with wireless m-bus transponders installed in almost all surrounding buildings.

  4. Calibration of ionization chamber survey meter

    International Nuclear Information System (INIS)

    Kadhim, A.K.; Kadni, T.B.

    2016-01-01

    Radiation measuring devices need to process calibration which lose their sensitivity and the extent of the response and the amount of stability under a changing conditions from time to time and this period depends on the nature and use of field in which used devices. A comparison study was done toa (45 I P) ( ionization chamber survey meter) and this showed the variation factor in five different years. This study also displayed the concept of radiation instrument calibration and necessity of every year calibration of them.In this project we used the five years calibration data for ionization chamber survey meter model Inspector (1/C F). the value deviation (∆ %) of Cfs for four years of calibration in comparison of C F for the year 2007 are very high and the device under research is not good to use in field and reliable because the ionization chamber is very sensitive to humidity and must calibrate a year or less, or due ing every two years and must maintain carefully to reduce the discarded effects the measurements.

  5. Intelligent Metering for Urban Water: A Review

    Directory of Open Access Journals (Sweden)

    Rodney Stewart

    2013-07-01

    Full Text Available This paper reviews the drivers, development and global deployment of intelligent water metering in the urban context. Recognising that intelligent metering (or smart metering has the potential to revolutionise customer engagement and management of urban water by utilities, this paper provides a summary of the knowledge-base for researchers and industry practitioners to ensure that the technology fosters sustainable urban water management. To date, roll-outs of intelligent metering have been driven by the desire for increased data regarding time of use and end-use (such as use by shower, toilet, garden, etc. as well as by the ability of the technology to reduce labour costs for meter reading. Technology development in the water sector generally lags that seen in the electricity sector. In the coming decade, the deployment of intelligent water metering will transition from being predominantly “pilot or demonstration scale” with the occasional city-wide roll-out, to broader mainstream implementation. This means that issues which have hitherto received little focus must now be addressed, namely: the role of real-time data in customer engagement and demand management; data ownership, sharing and privacy; technical data management and infrastructure security, utility workforce skills; and costs and benefits of implementation.

  6. Research on Operation Assessment Method for Energy Meter

    Science.gov (United States)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng

    2018-03-01

    The existing electric energy meter rotation maintenance strategy regularly checks the electric energy meter and evaluates the state. It only considers the influence of time factors, neglects the influence of other factors, leads to the inaccuracy of the evaluation, and causes the waste of resources. In order to evaluate the running state of the electric energy meter in time, a method of the operation evaluation of the electric energy meter is proposed. The method is based on extracting the existing data acquisition system, marketing business system and metrology production scheduling platform that affect the state of energy meters, and classified into error stability, operational reliability, potential risks and other factors according to the influencing factors, based on the above basic test score, inspecting score, monitoring score, score of family defect detection. Then, according to the evaluation model according to the scoring, we evaluate electric energy meter operating state, and finally put forward the corresponding maintenance strategy of rotation.

  7. Analogy between a flapping wing and a wind turbine with a vertical axis of revolution

    Science.gov (United States)

    Gorelov, D. N.

    2009-03-01

    Based on an analysis of available experimental data, the hypothesis about an analogy between a flapping wing and a wind turbine of the Darrieus rotor type is justified. It is demonstrated that the torque on the shaft of the Darrieus rotor is generated by thrust forces acting on the blades in a pulsed flow. A conclusion is drawn that it is necessary to perform aerodynamic calculations of blades on the basis of the nonlinear theory of the wing in an unsteady flow with allowance for the airfoil thickness.

  8. PELATIHAN RENANG GAYA DADA 8 KALI 25 METER 4 SET LEBIH MENINGKATKAN KECEPATAN RENANG 100 METER GAYA DADA DARIPADA 4 KALI 50 METER 4 SET PADA RENANG PEMULA PUTRA

    Directory of Open Access Journals (Sweden)

    I Wayan Suarta

    2013-07-01

    Full Text Available Sports pool in Indonesia are well known to the public, which is reduced when driving (after the end of the recovery to begin hand pull another hand, the breaststroke is the style of the most interesting because it does not quickly tiring when compared with other styles, because the process of respiration take place with ease, making them easier use in long-distance swim, at the start to affect the pace to continue this next movement needs to get training and a variety of training models, especially at students aged 10-12 years. Training pool 8 times 25 times 50 meters and 4 meters is one of the training methods that can speed up travel time. The best training model has not been encountered in the data. So do the research to find a model training 25 meter pool 8 times and 4 times 4 sets of 50 meters. The study was conducted with pretest-postes group design. Samples taken from the novice swimmer Toya Ening on Dalung Badung, as many as 26 people were randomly selected simple. Samples were divided into 2 groups each group totaled 13 people. Both groups were equally give training in the first group to pool 8 by 25 feet 4 sets, and 4 times the second group of 4 sets of 50 meters. 0.05 ab. Differences in results were analyzed statistically with  The data analyzed were age, height, weight, leg length and physical fitness.  13.49 seconds.± 107.69, and 126.38 ±The mean test results of the final 100 meter breaststroke swimming in a row 12.14 seconds  F count the results obtained respectively by 0.95 seconds with p = 0.59 and 0.93 seconds with a value of p = 0.34. Data showed significant differences significant (p> 0.05. These results indicate that the training of swimming the breaststroke 8 by 25 feet 4 sets is better than 4 times in 4 sets of 50 meter speed up travel time 100-meter breaststroke swimming novice men (p <0.05. Suggested the use of breaststroke swimming training method 8 by 25 feet 4 sets to be intensified to provide training pool at 100

  9. Suitable RF spectrum in ISM band for 2-way advanced metering network in India

    Science.gov (United States)

    Mishra, A.; Khan, M. A.; Gaur, M. S.

    2013-01-01

    The ISM (Industrial Scientific and Medical) bands in the radio frequency space in India offer two alternative spectra to implement wireless network for advanced metering infrastructure (AMI). These bands lie in the range of 2.4GHz and sub-GHz frequencies 865 to 867 MHz This paper aims to examine the suitability of both options by designing and executing experiments in laboratory as well as carrying out field trials on electricity meters to validate the selected option. A parameter, communication effectiveness index (CEI2) is defined to measure the effectiveness of 2 way data communication (packet exchange) between two points under different scenarios of buildings and free space. Both 2.4 GHz and Sub-GHz designs were implemented to compare the results. The experiments were conducted across 3 floors of a building. Validation of the selected option was carried out by conducting a field trial by integrating the selected radio frequency (RF) modem into the single phase electricity meters and installing these meters across three floors of the building. The methodology, implementation details, observations and resulting analytical conclusion are described in the paper.

  10. 10 CFR 451.7 - Metering requirements.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Metering requirements. 451.7 Section 451.7 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION RENEWABLE ENERGY PRODUCTION INCENTIVES § 451.7 Metering requirements. The net electric energy generated and sold (kilowatt-hours) by the owner or operator of a qualified...

  11. A Scalable Smart Meter Data Generator Using Spark

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Liu, Xiufeng; Danalachi, Sergiu

    2017-01-01

    Today, smart meters are being used worldwide. As a matter of fact smart meters produce large volumes of data. Thus, it is important for smart meter data management and analytics systems to process petabytes of data. Benchmarking and testing of these systems require scalable data, however, it can ...

  12. Multichannel Distribution Meter: A Veritable Solution in Power ...

    African Journals Online (AJOL)

    Partitioned apartments in commercial buildings particularly in congested environments shares energy supply meters among several users. This often leads to disputes and results to power theft in the form of unpaid bills and meter tampering. This paper described how power from a single supply meter can be adequately ...

  13. 40 CFR 1065.245 - Sample flow meter for batch sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Sample flow meter for batch sampling... Sample flow meter for batch sampling. (a) Application. Use a sample flow meter to determine sample flow... difference between a diluted exhaust sample flow meter and a dilution air meter to calculate raw exhaust flow...

  14. The relationships between common measures of glucose meter performance.

    Science.gov (United States)

    Wilmoth, Daniel R

    2012-09-01

    Glucose meter performance is commonly measured in several different ways, including the relative bias and coefficient of variation (CV), the total error, the mean absolute relative deviation (MARD), and the size of the interval around the reference value that would be necessary to contain a meter measurement at a specified probability. This fourth measure is commonly expressed as a proportion of the reference value and will be referred to as the necessary relative deviation. A deeper understanding of the relationships between these measures may aid health care providers, patients, and regulators in comparing meter performances when different measures are used. The relationships between common measures of glucose meter performance were derived mathematically. Equations are presented for calculating the total error, MARD, and necessary relative deviation using the reference value, relative bias, and CV when glucose meter measurements are normally distributed. When measurements are also unbiased, the CV, total error, MARD, and necessary relative deviation are linearly related and are therefore equivalent measures of meter performance. The relative bias and CV provide more information about meter performance than the other measures considered but may be difficult for some audiences to interpret. Reporting meter performance in multiple ways may facilitate the informed selection of blood glucose meters. © 2012 Diabetes Technology Society.

  15. Wanted: competitive metering infrastructure. Metering must be automated in a high grade; Gesucht: wettbewerbsfaehige Metering-Infrastruktur. Metering muss hochgradig automatisiert werden

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Elschner, C. [T-Systems Enterprise Services GmbH, Bonn (Germany). Business Development und Marketing

    2008-04-21

    Accurate on-time consumption metering and data transmission are increasingly important as energy markets are being deregulated. Measuring and information systems combine measurements with intelligent modules for automatic transmission of consumption information. A meaningful cost-benefit comparision results only when the total system is considered. Telecommunication companies as ICT service systems and service sectors can do a clear contribution to the total system. (orig./GL)

  16. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Inspiratory airway pressure meter. 868.1780 Section 868.1780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the amount...

  17. Analysis of a quantum nondemolition speed-meter interferometer

    International Nuclear Information System (INIS)

    Purdue, Patricia

    2002-01-01

    In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g. LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors rather than monitoring their relative position. This paper describes and analyzes the most straightforward design for a speed meter interferometer that accomplishes this--a design (due to Braginsky, Gorodetsky, Khalili and Thorne) that is analogous to a microwave-cavity speed meter conceived by Braginsky and Khalili. A mathematical mapping between the microwave speed meter and the optical interferometric speed meter is developed and is used to show [in accord with the speed being a quantum nondemolition observable] that in principle the interferometric speed meter can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies, and can do so without the use of squeezed vacuum or any auxiliary filter cavities at the interferometer's input or output. However, in practice, to reach or beat the SQL, this specific speed meter requires exorbitantly high input light power. The physical reason for this is explored, along with other issues such as constraints on performance due to optical dissipation. This analysis forms a foundation for ongoing attempts to develop a more practical variant of an interferometric speed meter and to combine the speed meter concept with other ideas to yield a promising LIGO-III/EURO interferometer design that entails low laser power

  18. Metering in the gas supply sector; Metering in der Gasversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Wernekinck, U. [RWE Westfalen-Weser-Ems, Recklinghausen (Germany)

    2007-10-15

    The new conditions of competition in the gas supply sector have strongly increased the requirements on gas grid operators. Mainly an exact gas metering and -accouting will become more and more important. The systems and procedures are presented in detail in this contribution. (GL)

  19. Modal analysis of a small vertical axis wind turbine (Type DARRIEUS

    Directory of Open Access Journals (Sweden)

    Ion NILA

    2012-06-01

    Full Text Available This paper reports a brief study on free vibration analysis for determining parameters such as natural frequencies and mode shapes for vertical axis wind turbines (VAWT for an urban application. This study is focused on numerical work using available finite element software. For further understanding of the wind turbine dynamic analysis, two vibration parameters of dynamic response have been studied, namely natural frequencies and mode shapes.Block Lanczos method has been used to analyze the natural frequency while wind turbine mode shapes have been utilized because of their accuracy and faster solution. In this problem 12 modes of structure have been extracted.

  20. RAE: The Rainforest Automation Energy Dataset for Smart Grid Meter Data Analysis

    Directory of Open Access Journals (Sweden)

    Stephen Makonin

    2018-02-01

    Full Text Available Datasets are important for researchers to build models and test how well their machine learning algorithms perform. This paper presents the Rainforest Automation Energy (RAE dataset to help smart grid researchers test their algorithms that make use of smart meter data. This initial release of RAE contains 1 Hz data (mains and sub-meters from two residential houses. In addition to power data, environmental and sensor data from the house’s thermostat is included. Sub-meter data from one of the houses includes heat pump and rental suite captures, which is of interest to power utilities. We also show an energy breakdown of each house and show (by example how RAE can be used to test non-intrusive load monitoring (NILM algorithms.

  1. A flow meter for ultrasonically measuring the flow velocity of fluids

    DEFF Research Database (Denmark)

    2015-01-01

    The invention regards a flow meter for ultrasonically measuring the flow velocity of fluids comprising a duct having a flow channel with an internal cross section comprising variation configured to generate at least one acoustic resonance within the flow channel for a specific ultrasonic frequency......, and at least two transducers for generating and sensing ultrasonic pulses, configured to transmit ultrasonic pulses at least at said specific ultrasonic frequency into the flow channel such that the ultrasonic pulses propagate through a fluid flowing in the flow channel, wherein the flow meter is configured...

  2. Smart Metering. Synergies within medium voltage automation; Synergien durch Smart Metering. Automatisierung auf Mittelspannungsebene

    Energy Technology Data Exchange (ETDEWEB)

    Maas, Peter [IDS GmbH, Ettlingen (Germany)

    2010-11-15

    Transparent interdivisional system solutions are an indispensable and decisive precondition for the optimization of business processes. The implementation of a Smart Metering solution does not only provide data for billing purposes, but also renders important data for network operation. Synergies can be achieved through the use of a common infrastructure which covers both the needs of Smart Metering and network operation. An open architecture of the solution allows for the future integration of further services of the domains Smart Grid and Smart Home. (orig.)

  3. Smart meters and routers radiofrequency disturbances study with pacemakers and implantable cardiac defibrillators.

    Science.gov (United States)

    Ostiguy, Geneviève; Black, Tom; Bluteau, Louis-Jean; Dupont, Louis; Dyrda, Katia; Girard, Guillaume; Nguyen, Duc-Hai; Plante, Michel; Thibault, Bernard

    2013-11-01

    There is no scientific literature that examines radiofrequency (RF) interference from Smart Meters with cardiac implantable electronic devices (CIEDs). The objective of this in vitro study was to assess any potential interference with Medtronic CIEDs (Medtronic Inc., Minneapolis, MN, USA). In the Quebec testing, five models of Medtronic CIEDs were placed in an acrylic cylinder filled with a saline solution and faced a Landis+Gyr Smart Meter or Router (Landis+Gyr AG, Zug, Switzerland). The distance between CIEDs and the meter casing or router antenna was 10 cm. The Meter's normal operating conditions were modified to artificially set the number of impulsions at an abnormally high level (one, two, and three impulses per second). Each scenario was repeated one to five times, for 1 minute each. In the U.S. testing, 6 cm and 15 cm (∼2.25' and ∼6') separated the six models of Medtronic CIEDs from the Schlumberger Smart Meter (Itron Inc., Liberty Lake, WA, USA), which generally sent out a 96-bit Standard Consumption Message over 3 seconds. The transmission varied in frequencies along with the interval between cycles. A total of 6,966 RF transmissions were completed during the 34 tests conducted in Quebec. In the United States, the CIED was exposed to the meter for 10 minutes to provide a minimum of 200 completed RF transmissions. No interference was observed in worst-case scenarios (testing of meters and CIEDs at their performance limits). Landis+Gyr Smart Meters/Routers and Schlumberger Smart Meters do not interfere with the functioning of the Medtronic CIEDs tested, when placed, respectively, 10 cm and 6 cm and 15 cm apart. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  4. Calibration of dose meters used in radiotherapy

    International Nuclear Information System (INIS)

    1979-01-01

    This manual is a practical guide, not a comprehensive textbook, to the instrumentation and procedures necessary to calibrate a radiation dose meter used in clinical practice against a secondary standard dose meter

  5. In-situ calibration of clinical built-in KAP meters with traceability to a primary standard using a reference KAP meter.

    Science.gov (United States)

    Malusek, A; Helmrot, E; Sandborg, M; Grindborg, J-E; Carlsson, G Alm

    2014-12-07

    The air kerma-area product (KAP) is used for settings of diagnostic reference levels. The International Atomic Energy Agency (IAEA) recommends that doses in diagnostic radiology (including the KAP values) be estimated with an accuracy of at least ± 7% (k = 2). Industry standards defined by the International Electrotechnical Commission (IEC) specify that the uncertainty of KAP meter measurements should be less than ± 25% (k = 2). Medical physicists willing to comply with the IAEA's recommendation need to apply correction factors to KAP values reported by x-ray units. The aim of this work is to present and evaluate a calibration method for built-in KAP meters on clinical x-ray units. The method is based on (i) a tandem calibration method, which uses a reference KAP meter calibrated to measure the incident radiation, (ii) measurements using an energy-independent ionization chamber to correct for the energy dependence of the reference KAP meter, and (iii) Monte Carlo simulations of the beam quality correction factors that correct for differences between beam qualities at a standard laboratory and the clinic. The method was applied to the KAP meter in a Siemens Aristos FX plus unit. It was found that values reported by the built-in KAP meter differed from the more accurate values measured by the reference KAP meter by more than 25% for high tube voltages (more than 140 kV) and heavily filtered beams (0.3 mm Cu). Associated uncertainties were too high to claim that the IEC's limit of 25% was exceeded. Nevertheless the differences were high enough to justify the need for a more accurate calibration of built-in KAP meters.

  6. Analysing Smart Metering Systems from a Consumer Perspective

    Science.gov (United States)

    Yesudas, Rani

    Many countries are deploying smart meters and Advanced Metering Infrastructure systems as part of demand management and grid modernisation efforts. Several of these projects are facing consumer resistance. The advertised benefits to the consumer appear mainly monetary but detailed analysis shows that financial benefits are hard to realise since the fixed services charges are high. Additionally, the data collected from smart meters have security and privacy implications for the consumer. These projects failed to consider end-users as an important stakeholder group during planning stages resulting in the design and roll-out of expensive systems, which do not demonstrate clear consumer benefits. The overall goal of the research reported in this thesis was to improve the smart metering system to deliver consumer benefits that increase confidence and acceptance of these projects. The smart metering system was examined from an end-user perspective for realistic insights into consumer concerns. Processes from Design Science Research methodology were utilised to conduct this research due to the utilitarian nature of the objective. Consumer segmentation was central to the proposed measures. Initially, a consumer-friendly risk analysis framework was devised, and appropriate requirement elicitation techniques were identified. Control options for smart meter data transfer and storage were explored. Various scenarios were analysed to determine consumer-friendly features in the smart metering system, including control options for smart meter data transfer and storage. Proposed functionalities (billing choices, feedback information and specific configurations to match the needs of different user segments) were studied using the Australian smart metering system. Smart meters vary in capabilities depending on the manufacturer, mode and place of deployment. The research showed that features proposed in this thesis are implementable in smart meters, by examining their applicability

  7. Liquid ultrasonic flow meters for crude oil measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kalivoda, Raymond J.; Lunde, Per

    2005-07-01

    Liquid ultrasonic flow meters (LUFMs) are gaining popularity for the accurate measurement of petroleum products. In North America the first edition of the API standard ''Measurement of liquid hydrocarbons by ultrasonic flow meters using transit time technology'' was issued in February 2005. It addresses both refined petroleum products and crude oil applications. Its field of application is mainly custody transfer applications but it does provide general guidelines for the installation and operation of LUFM's other applications such as allocation, check meters and leak detection. As with all new technologies performance claims are at times exaggerated or misunderstood and application knowledge is limited. Since ultrasonic meters have no moving parts they appear to have fewer limitations than other liquid flow meters. Liquids ultrasonic flow meters, like turbine meters, are sensitive to fluid properties. It is increasingly more difficult to apply on high viscosity products then on lighter hydrocarbon products. Therefore application data or experience on the measurement of refined or light crude oil may not necessarily be transferred to measuring medium to heavy crude oils. Before better and more quantitative knowledge is available on how LUFMs react on different fluids, the arguments advocating reduced need for in-situ proving and increased dependency on laboratory flow calibration (e.g. using water instead of hydrocarbons) may be questionable. The present paper explores the accurate measurement of crude oil with liquid ultrasonic meters. It defines the unique characteristics of the different API grades of crude oils and how they can affect the accuracy of the liquid ultrasonic measurement. Flow testing results using a new LUFM design are discussed. The paper is intended to provide increased insight into the potentials and limitations of crude oil measurement using ultrasonic flow meters. (author) (tk)

  8. Extracting urban water usage habits from smart meter data: a functional clustering approach

    OpenAIRE

    CHEIFETZ, Nicolas; SAME, Allou; NOUMIR, Zineb; SANDRAZ, Anne Claire; FELIERS, Cédric; HEIM, Véronique

    2017-01-01

    Through automated meter reading systems, recent development of smart grids offers the opportunity for an efficient and responsible management of water resources. The present paper describes a novel methodology for identifying relevant usage profiles from hourly water consumption series collected by smart meters located on a water distribution network. The proposed approach operates in two stages. First, an additive time series decomposition model is used in order to extract seasonal patterns ...

  9. Knowledge is power: Customer load metering in the Victorian End-Use Measurement Program

    Energy Technology Data Exchange (ETDEWEB)

    Gavin, G. [CitiPower Ltd., Melbourne, VIC (Australia)

    1995-12-31

    The Victorian End-Use Measurement Program is a sophisticated load metering program being conducted over 500 sites in Victoria, covering the major customer sectors of residential, commercial and industrial. Its goal is to gather sufficient data to determine with statistical accuracy the load profiles of these major sectors, together with the load profiles of selected customer end-uses in the residential and commercial sectors, and selected building types in the commercial sector. This paper discusses the major elements of the program, the history of its development, the design of the statistical and operational components of the program, and its implementation in the field. In the Victorian electricity industry, with the combination of contestable customer metering and the End-Use Measurement program metering for the franchise/non-contestable market, there is now a considerable flow of customer load data. The opportunity exists for an accurate understanding of customer load needs, and the minimization of risk in business operations in the retail and wholesale market. (author).

  10. Ipratropium bromide delivered by metered-dose aerosol to infant ...

    African Journals Online (AJOL)

    Two methods of administration of ipratropium bromide (Atrovent; Boehringer Ingelheim) to wheezing children'< 25 months of age were compared: (i) the conventional nebulisation (15 children); and (ii) a metered-dose aerosol plus spacer and mask (MDA group, 17 children). The drug induced a significant and similar fall in ...

  11. Design and construction techniques for one-meter position sensitive proportional counters of the helical delay line type

    International Nuclear Information System (INIS)

    Orbesen, S.D.; Sherman, J.D.; Flynn, E.R.

    1976-03-01

    A description is given of the techniques involved in the construction of a one-meter long helical proportional counter which produces excellent position accuracy of 1 mm while yielding particle identification through a measurement of energy loss and total energy

  12. Synergisms between smart metering and smart grid; Synergien zwischen Smart Metering und Smart Grid

    Energy Technology Data Exchange (ETDEWEB)

    Maas, Peter [IDS GmbH, Ettlingen (Germany)

    2010-04-15

    With the implementation of a smart metering solution, it is not only possible to acquire consumption data for billing but also to acquire relevant data of the distribution grid for grid operation. There is still a wide gap between the actual condition and the target condition. Synergies result from the use of a common infrastructure which takes account both of the requirements of smart metering and of grid operation. An open architecture also enables the future integration of further applications of the fields of smart grid and smart home. (orig.)

  13. Advanced Metering Installations – A Perspective from Federal Sites

    Energy Technology Data Exchange (ETDEWEB)

    Earni, Shankar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area

    2016-05-02

    This report is intended to provide guidance to the United States Department of Energy (DOE) and other federal agencies to highlight some of the existing practices related to advanced building metering systems. This study identified some of the existing actions related to advanced meter data and proposes how advanced metered data can be employed to develop robust cost effective measurement and verification (M&V) strategies. This report proposes an integrated framework on how advanced meter data can be used to identify energy conservation opportunities and to develop proactive M&V strategies to ensure that the savings for energy projects are being realized. This information will help improve metering, feedback, and dashboard implementations for reducing energy use at DOE facilities, based on lessons learned from various advanced metering implementations.

  14. Calibration for radiation protection survey meter SSM1

    International Nuclear Information System (INIS)

    Jin Hua.

    1992-03-01

    The calibration functions for the Radiation Protection Survey Meter SSM1 built-in Geiger Mueller measuring tubes of the type ZP 1201 (low dose rate tube) and ZP 1313 (high dose rate tube) are given in the present study. Six dose rate points are proposed as the calibration points of covering the range from 500 nSv/h up to 5 Sv/h. The difference between the true dose rate and the values calculated with the method in this paper for No. 382 SSM1 is less than ±2%. (author)

  15. FLOW METERS WITH VERY GOOD PERFORMANCES

    Directory of Open Access Journals (Sweden)

    Mircea Dimitrie CAZACU

    2011-11-01

    Full Text Available We present the theoretical calculus of a patented flow meter, concerning such the thermodynamic and aerodynamic calculus, as well as the offered precision to measure the flow of the air in any meteorological conditions. In the same time we remark that the proposed flow meter, by its positioning, has not loss of head.

  16. Navy-New Hampshire Wind Energy Program.

    Science.gov (United States)

    1979-11-01

    wind use for both the MOD-2 and Darrieus wind turbine -generators when located on these peaks. lIT...Horizontal Axis WECS 10 2-4 Darrieus Vertical Axis Wind Turbine 12 2-5 Alcoa Design for 500 kW Vertical Axis WECS 13 3-1 Fraction of Wind Observations... Turbines In 1925, G.J.M. Darrieus patented the concept of a vertical axis wind turbine . Today, the Darrieus design has evolved to a fixed-pitch

  17. Tapping to a slow tempo in the presence of simple and complex meters reveals experience-specific biases for processing music.

    Directory of Open Access Journals (Sweden)

    Sangeeta Ullal-Gupta

    Full Text Available Musical meters vary considerably across cultures, yet relatively little is known about how culture-specific experience influences metrical processing. In Experiment 1, we compared American and Indian listeners' synchronous tapping to slow sequences. Inter-tone intervals contained silence or to-be-ignored rhythms that were designed to induce a simple meter (familiar to Americans and Indians or a complex meter (familiar only to Indians. A subset of trials contained an abrupt switch from one rhythm to another to assess the disruptive effects of contradicting the initially implied meter. In the unfilled condition, both groups tapped earlier than the target and showed large tap-tone asynchronies (measured in relative phase. When inter-tone intervals were filled with simple-meter rhythms, American listeners tapped later than targets, but their asynchronies were smaller and declined more rapidly. Likewise, asynchronies rose sharply following a switch away from simple-meter but not from complex-meter rhythm. By contrast, Indian listeners performed similarly across all rhythm types, with asynchronies rapidly declining over the course of complex- and simple-meter trials. For these listeners, a switch from either simple or complex meter increased asynchronies. Experiment 2 tested American listeners but doubled the duration of the synchronization phase prior to (and after the switch. Here, compared with simple meters, complex-meter rhythms elicited larger asynchronies that declined at a slower rate, however, asynchronies increased after the switch for all conditions. Our results provide evidence that ease of meter processing depends to a great extent on the amount of experience with specific meters.

  18. Tapping to a slow tempo in the presence of simple and complex meters reveals experience-specific biases for processing music.

    Science.gov (United States)

    Ullal-Gupta, Sangeeta; Hannon, Erin E; Snyder, Joel S

    2014-01-01

    Musical meters vary considerably across cultures, yet relatively little is known about how culture-specific experience influences metrical processing. In Experiment 1, we compared American and Indian listeners' synchronous tapping to slow sequences. Inter-tone intervals contained silence or to-be-ignored rhythms that were designed to induce a simple meter (familiar to Americans and Indians) or a complex meter (familiar only to Indians). A subset of trials contained an abrupt switch from one rhythm to another to assess the disruptive effects of contradicting the initially implied meter. In the unfilled condition, both groups tapped earlier than the target and showed large tap-tone asynchronies (measured in relative phase). When inter-tone intervals were filled with simple-meter rhythms, American listeners tapped later than targets, but their asynchronies were smaller and declined more rapidly. Likewise, asynchronies rose sharply following a switch away from simple-meter but not from complex-meter rhythm. By contrast, Indian listeners performed similarly across all rhythm types, with asynchronies rapidly declining over the course of complex- and simple-meter trials. For these listeners, a switch from either simple or complex meter increased asynchronies. Experiment 2 tested American listeners but doubled the duration of the synchronization phase prior to (and after) the switch. Here, compared with simple meters, complex-meter rhythms elicited larger asynchronies that declined at a slower rate, however, asynchronies increased after the switch for all conditions. Our results provide evidence that ease of meter processing depends to a great extent on the amount of experience with specific meters.

  19. Smart Metering: Learning from telecommunication providers. Innovative customized products; Beim Smart Metering von Telekommunikationsanbietern lernen. Innovative Buendelprodukte

    Energy Technology Data Exchange (ETDEWEB)

    Isbrecht, Volker; Sombrutzki, Ingo [Putz und Partner Unternehmensberatung AG, Hamburg (Germany). Strategie- und Projektmanagement - Energiewirtschaft; Hofer, Kristina [Putz und Partner Unternehmensberatung AG, Hamburg (Germany). CRM- und Telekommunikation

    2010-04-06

    Deregulation in the electricity and gas metering has raised interest in smart meters. Experts estimate that in a four-person household, smart meters may reduce electricity consumption by up to 10 percent, i.e. 50 - 90 Euros, and CO2 emissions by 8.5 million tonnes, which amounts to 4 percent of the total CO2 emissions in Germany. These are ideal conditions for utilities to develop innovative products for the mass market of private consumers and to improve their competitive standing in the market by a clearly communicated advantage to both the customers and the climate. By utilizing the experience gained in the telecommunications industry, they will be able to respond quickly to impending challenges. (orig.)

  20. A simple protocol for the routine calibration of pH meters

    Directory of Open Access Journals (Sweden)

    A. FEDERMAN NETO

    2009-01-01

    Full Text Available

    A simplified laboratory protocol for the calibration of pH meters is described and tested. It is based on the use of two analytical primary buffer solutions, potassium hydrogen phthalate and Borax (sodium tetraborate decahydrate of precisely known concentrations and pH. The solutions may be stored at room temperature for long periods, without decomposition and used directly. The calibration of the meter can be checked with standard solutions of sodium dihydrogen phosphate, sodium carbonate, sodium benzoate, sodium salicylate or potassium oxalate. Methods for the purification of Borax and potassium chloride are also given, and a new method for the neutralization of 0.9% saline is suggested. Keywords: pH meters (calibration; saline (0.9%; pH standards; potassium biphthalate; Borax.

  1. Ipratropium bromide delivered by metered-dose aerosol to infant ...

    African Journals Online (AJOL)

    1990-08-21

    Aug 21, 1990 ... Two methods of administration of ipratropium bromide. (Atrovent; Boehringer Ingelheim) to wheezing children'< 25 months of age were compared: (I) the conventional nebulisa- tion (15 children); and (iI) a metered-dose aerosol plus spacer and mask (MDA group, 17 children). The drug induced a significant ...

  2. A Prediction-based Smart Meter Data Generator

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Liu, Xiufeng; Nordbjerg, Finn Ebertsen

    2016-01-01

    With the prevalence of cloud computing and In-ternet of Things (IoT), smart meters have become one of the main components of smart city strategy. Smart meters generate large amounts of fine-grained data that is used to provide useful information to consumers and utility companies for decision......, mainly due to privacy issues. This paper proposes a smart meter data generator that can generate realistic energy consumption data by making use of a small real-world dataset as seed. The generator generates data using a prediction-based method that depends on historical energy consumption patterns along......-making. Now-a-days, smart meter analytics systems consist of analytical algorithms that process massive amounts of data. These analytics algorithms require ample amounts of realistic data for testing and verification purposes. However, it is usually difficult to obtain adequate amounts of realistic data...

  3. Bandwidth Analysis of Smart Meter Network Infrastructure

    DEFF Research Database (Denmark)

    Balachandran, Kardi; Olsen, Rasmus Løvenstein; Pedersen, Jens Myrup

    2014-01-01

    Advanced Metering Infrastructure (AMI) is a net-work infrastructure in Smart Grid, which links the electricity customers to the utility company. This network enables smart services by making it possible for the utility company to get an overview of their customers power consumption and also control...... devices in their costumers household e.g. heat pumps. With these smart services, utility companies can do load balancing on the grid by shifting load using resources the customers have. The problem investigated in this paper is what bandwidth require-ments can be expected when implementing such network...... to utilize smart meters and which existing broadband network technologies can facilitate this smart meter service. Initially, scenarios for smart meter infrastructure are identified. The paper defines abstraction models which cover the AMI scenarios. When the scenario has been identified a general overview...

  4. A neutron dose equivalent meter at CAEP

    International Nuclear Information System (INIS)

    Tian Shihai; Lu Yan; Wang Heyi; Yuan Yonggang; Chen Xu

    2012-01-01

    The measurement of neutron dose equivalent has been a widespread need in industry and research. In this paper, aimed at improving the accuracy of neutron dose equivalent meter: a neutron dose counter is simulated with MCNP5, and the energy response curve is optimized. The results show that the energy response factor is from 0.2 to 1.8 for neutrons in the energy range of 2.53×10 -8 MeV to 10 MeV Compared with other related meters, it turns that the design of this meter is right. (authors)

  5. HJD-I record and analysis meter for nuclear information

    International Nuclear Information System (INIS)

    Di Shaoliang; Huang Yong; Xiao Yanbin

    1992-01-01

    A low-cost, small-volume, multi-function and new model intelligent nuclear electronic meter HJD-I Record and Analysis Meter are stated for Nuclear Information. It's hardware and software were detailed and the 137 Cs spectrum with this meter was presented

  6. Adjustment equipment for reactor radioactivity meter

    International Nuclear Information System (INIS)

    Denisov, V.P.; Malishev, A.N.; Shebanova, L.E.; Kirilyuk, N.A.; Maksimov, Yu.N.; Bessalov, G.G.; Vikhorev, Yu.V.; Lukyanov, M.A.

    1978-01-01

    An activity meter is described movably located in a channel placed in the peripheral biological shielding of a nuclear reactor. It is connected to a weight moving in a second channel by means of a pulley. This arrangement allows locating the radioactivity meter drive on the outer side of the biological shield and vacating space above the reactor body. (Ha)

  7. The reactivity meter and core reactivity

    International Nuclear Information System (INIS)

    Siltanen, P.

    1999-01-01

    This paper discussed in depth the point kinetic equations and the characteristics of the point kinetic reactivity meter, particularly for large negative reactivities. From a given input signal representing the neutron flux seen by a detector, the meter computes a value of reactivity in dollars (ρ/β), based on inverse point kinetics. The prompt jump point of view is emphasised. (Author)

  8. Household Classification Using Smart Meter Data

    Directory of Open Access Journals (Sweden)

    Carroll Paula

    2018-03-01

    Full Text Available This article describes a project conducted in conjunction with the Central Statistics Office of Ireland in response to a planned national rollout of smart electricity metering in Ireland. We investigate how this new data source might be used for the purpose of official statistics production. This study specifically looks at the question of determining household composition from electricity smart meter data using both Neural Networks (a supervised machine learning approach and Elastic Net Logistic regression. An overview of both classification techniques is given. Results for both approaches are presented with analysis. We find that the smart meter data alone is limited in its capability to distinguish between household categories but that it does provide some useful insights.

  9. Water velocity meter

    Science.gov (United States)

    Roberts, C. W.; Smith, D. L.

    1970-01-01

    Simple, inexpensive drag sphere velocity meter with a zero to 6 ft/sec range measures steady-state flow. When combined with appropriate data acquisition system, it is suited to applications where large numbers of simultaneous measurements are needed for current mapping or velocity profile determination.

  10. Development and evaluation of an ultrasonic ground water seepage meter.

    Science.gov (United States)

    Paulsen, R J; Smith, C F; O'Rourke, D; Wong, T F

    2001-01-01

    Submarine ground water discharge can influence significantly the near-shore transport and flux of chemicals into the oceans. Quantification of the sources and rates of such discharge requires a ground water seepage meter that provides continuous measurements at high resolution over an extended period of time. An ultrasonic flowmeter has been adapted for such measurements in the submarine environment. Connected to a steel collection funnel, the meter houses two piezoelectric transducers mounted at opposite ends of a cylindrical flow tube. By monitoring the perturbations of fluid flow on the propagation of sound waves inside the flow tube, the ultrasonic meter can measure both forward and reverse fluid flows in real time. Laboratory and field calibrations show that the ultrasonic meter can resolve ground water discharges on the order of 0.1 microm/sec, and it is sufficiently robust for deployment in the field for several days. Data from West Neck Bay, Shelter Island, New York, elucidate the temporal and spatial heterogeneity of submarine ground water discharge and its interplay with tidal loading. A negative correlation between the discharge and tidal elevation was generally observed. A methodology was also developed whereby data for the sound velocity as a function of temperature can be used to infer the salinity and source of the submarine discharge. Independent measurements of electrical conductance were performed to validate this methodology.

  11. 49 CFR 192.359 - Customer meter installations: Operating pressure.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meter installations: Operating pressure... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.359 Customer meter installations: Operating pressure...

  12. Tentative type test of a non-invasive high-voltage meter with respect to the quantity of practical peak voltage

    International Nuclear Information System (INIS)

    Peixoto, J.G.P.; Selbach, H.J.; Kramer, H.M.; Lange, B.

    2001-04-01

    In Working Group 3 of Sub-committee 62C of the international electrotechnical commission (IEC) a new project is underway [1] with the objective of specifying requirements for the performance characteristics of instruments for the non-invasive measurement of the X-ray tube voltage in diagnostic radiology. In this draft the X-ray tube voltage is specified in terms of the practical peak voltage [2]. The objective of the present work is to perform a tentative type test, based on the ''Requirements for Instruments for Non-invasive Measurements of the X-ray Tube Voltage'' defined in the IEC draft, with a commercially available non-invasive high-voltage meter. The instrument was modified so that the practical peak voltage can be measured. It is shown that the instrument, with the modifications made, is suitable for the non-invasive measurement of the practical peak voltage between 50 kV and 150 kV within the required limits of variation of the response. (orig.)

  13. Data acquisition and meter unit based in wifi communication protocol

    Directory of Open Access Journals (Sweden)

    Gerardo Cázarez Ayala

    2012-05-01

    Full Text Available Without doubt, the competitive fast rhythm of the industries is one of the main causes helped bring to the accelerated growth of the electronic technology and the communication. The need to develop new products with a best quality, cheaper and faster as assure and increase the quality of the products in the international markets, requires of new technologies to the metering, monitoring and control of their production processes, of which finality is to improve the processes to guaranteed their products in the market in the less time possible, the best quality and low cost for the final consumer. This work is based in the design and implementation of a Wireless Data Acquisition Unit based in WiFi protocol, which is oriented to meter, monitoring and the control of processes in the industry, commercial and the home automation applications, using one of the wirelessprotocols with the biggest acceptance in the market, with the main objective of to take advantage of the installed physical infrastructure in the place of the application, like industry, company or house. The Unit is based in the RN-131G, a Roving Network company module, which is able to work in stand-alone mode with ultralow power consummation and supporting the IEEE 802.11b/g protocols, in which is possible to achieve transfer rates of up to 11 Mbps and 54 Mbps in /b & /g specifications respectively. Whit this unit is possible to meter up to 5 analogs signals with 14 bits precision and has include a temperature and relative humidity sensors. This unit can meter two digital signals and act mean two digitals outputs, and gas include an USB port for communication and programming tasks.

  14. 49 CFR 192.357 - Customer meters and regulators: Installation.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meters and regulators: Installation. 192... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.357 Customer meters and regulators: Installation. (a...

  15. Apparent losses due to domestic water meter under-registration in ...

    African Journals Online (AJOL)

    By combining these results with the average age of meters in South Africa, estimated from the National Water Demand Archive, it was possible to estimate the average meter under-registration due to meter aging. The study concluded that apparent losses due to water meter under-registration are around 5% of consumption ...

  16. The water desalination complex based on ABV-type reactor plant

    International Nuclear Information System (INIS)

    Panov, Yu.K.; Fadeev, Yu.P.; Vorobiev, V.M.; Baranaev, Yu.D.

    1997-01-01

    A floating nuclear desalination complex with two barges, one for ABV type reactor plant, with twin reactor 2 x 6 MW(e), and one for reverse osmosis desalination plant, was described. The principal specifications of the ABV type reactor plant and desalination barge were given. The ABV type reactor has a traditional two-circuit layout using an integral type reactor vessel with all mode natural convection of primary coolant. The desalted water cost was estimated to be around US $0.86 per cubic meter. R and D work has been performed and preparations for commercial production are under way. (author)

  17. Fundamental studies on miniature dose meter using variable capacitance Si-diode

    International Nuclear Information System (INIS)

    Inoue, Yoshio

    1976-01-01

    The results of fundamental studies on development of a miniature dose meter using a semiconductor applicable for dosimetry in both intracavitary and external radiotherapy are described. Many different instruments have been applied in clinical dosimetry for regional lesions, mostly in phantom studies, e. g. the small sized ionization chamber, the fluoroluminescence glass dose meter and the thermoluminescence dose meter. However, there are considerable problems regarding safety, reproducibility, and simplicity for regional dosimetry of intracavitary lesions, such as genitourinary, gastrointestinal and respiratory malignancies. To overcome these problems, an attempt was made to develop a miniature catheter type detector using a variable capacitance Si-diode for gamma ray dosimetry. The newly developed miniature dose meter using a semiconductor has the following characteristics. As the tip of detector (23mm long and 3mm in diameter) is very small, the apparatus unit is easy to manipulate in the dosimetry of intracavitary lesions. As no voltage is supplied to the detector, there is no danger of electric shock from in vivo studies. A strict linearity existed between the radiation dose rate and the generated voltage even when the range of experimental irradiation dose rate was extremely wide. The sensitivity of the detector was affected by the environmental temperature, but it was easy to correct the sensitivity by applying a special calibration chart to the value derived from a thermister enclosed in the detector. Even with the experimental irradiation of more than 50,000R, no changes in the sensitivity of the detector were observed. Thus, the durability of the apparatus was shown to be excellent. (auth.)

  18. 40 CFR 92.122 - Smoke meter calibration.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Smoke meter calibration. 92.122 Section 92.122 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... meter calibration. The smokemeter shall be checked according to the following procedure prior to each...

  19. A tool to increase information-processing capacity for consumer water meter data

    Directory of Open Access Journals (Sweden)

    Heinz E. Jacobs

    2012-06-01

    Objective: The objective of this research article was to describe the development of Swift, a locally developed software tool for analysing water meter data from an information management perspective, which engineers in the water field generally use, and to assess critically the influence of Swift on published research and industry. This article focuses on water usage and the challenge of data interchange and extraction as issues that various industries face. Method: This article presents the first detailed report on Swift. It uses a detailed knowledge review and presents and summarises the findings chronologically. Results: The water meter data flow path used to be quite simple. The risk of breaches in confidentiality was limited. Technological advances over the years have led to additional knowledge coming from the same water meter readings with subsequent research outputs. However, there are also complicated data flow paths and increased risks. Users have used Swift to analyse more than two million consumers’ water meter readings to date. Studies have culminated in 10 peer-reviewed journal articles using the data. Seven of them were in the last five years. Conclusion: Swift-based data was the basis of various research studies in the past decade. Practical guidelines in the civil engineering fraternity for estimating water use in South Africa have incorporated knowledge from these studies. Developments after 1995 have increased the information processing capacity for water meter data.

  20. Integrating an embedded system in a microwave moisture meter

    Science.gov (United States)

    The conversion of a PC- or laptop-controlled microwave moisture meter to a stand-alone meter hosting its own embedded system is discussed. The moisture meter measures the attenuation and phase shift of low power microwaves traversing the sample, from which the dielectric properties are calculated. T...

  1. Assessment of the disc pasture meter on natural veld in the False ...

    African Journals Online (AJOL)

    The use of the standard disc pasture meter is found to be a reliable technique for estimating the yield of the densely tufted grass swards found in the False Thornveld of the Eastern Province. It compares favourably with traditional methods of yield estimation in the veld type and its attractiveness lies in the rapidity with which ...

  2. A Method of Evaluating Operation of Electric Energy Meter

    Science.gov (United States)

    Chen, Xiangqun; Li, Tianyang; Cao, Fei; Chu, Pengfei; Zhao, Xinwang; Huang, Rui; Liu, Liping; Zhang, Chenglin

    2018-05-01

    The existing electric energy meter rotation maintenance strategy regularly checks the electric energy meter and evaluates the state. It only considers the influence of time factors, neglects the influence of other factors, leads to the inaccuracy of the evaluation, and causes the waste of resources. In order to evaluate the running state of the electric energy meter in time, a method of the operation evaluation of the electric energy meter is proposed. The method is based on extracting the existing data acquisition system, marketing business system and metrology production scheduling platform that affect the state of energy meters, and classified into error stability, operational reliability, potential risks and other factors according to the influencing factors, based on the above basic test score, inspecting score, monitoring score, score of family defect detection. Then, according to the evaluation model according to the scoring, we evaluate electric energy meter operating state, and finally put forward the corresponding maintenance strategy of rotation.

  3. Vertical-axial component wind turbine with a high coefficient using for wind energy

    International Nuclear Information System (INIS)

    Yersin, Ch. Sh.; Manatbev, R.K.; Yersina, A. K.; Tulepbergenov, A. K.

    2012-01-01

    The report presents the results of research and development on of promising wind units carousel type with a high ratio utilization of wind energy. This devices use a well-known invention – the wind turbine Darrieus. The rotation of the turbine is due to the action of ascensional power to aerodynamic well-streamlined symmetrical about the chord wing profiles of NASA, which are working wind turbine blades. The shaft rotation can be connected with the working blades of one of two ways: using the “swings” or the way “troposkino”. Darrieus turbine has a ratio utilization of wind energy xmax=045. Despite the fact that this is a good indicator of the efficiency of the turbine working, the proposed option allows us to significantly increase the value of this coefficient. The bases methodology of this research is a method of technical and technological research and development design of prospective wind energy construction (WES). Key words: wind turbine, the blade, coefficient utilization of wind energy

  4. Characterization of radiofrequency field emissions from smart meters.

    Science.gov (United States)

    Tell, Richard A; Kavet, Robert; Mezei, Gabor

    2013-01-01

    This study presents measurement data that describe radiofrequency emission levels and patterns from smart meters (rated nominally at 1 W) currently deployed in Pacific Gas and Electric Company's service territory in northern California. The smart meters in our investigation could not be set to operate continuously and required a Field Service Unit to induce short periods of emitted fields. To obtain peak field data under both laboratory and ambient conditions, a spectrum analyzer scanned across the 83 transmitting channels between 902 and 928 MHz used by the smart meter on a random frequency-hopping basis. To obtain data describing temporal emission patterns, the analyzer operated in scope mode. Duty cycle was estimated using transmit data acquired by the system operator from over 88,000 m. Instantaneous peak fields at 0.3 m in front of the meters were no more than 15% of the US Federal Communications Commission (FCC) exposure limit for the general public, and 99.9% of the meters operated with a duty cycle of 1.12% or less during the sampling period. In a sample of measurements in six single-detached residences equipped with individual smart meters, no interior measurement of peak field exceeded 1% of the FCC's general public exposure limit.

  5. Design of Remote Heat-Meter System Based on Trusted Technology

    Science.gov (United States)

    Yu, Changgeng; Lai, Liping

    2018-03-01

    This article presents a proposal of a heat meter and remote meter reading system for the disadvantages of the hackers very easily using eavesdropping, tampering, replay attack of traditional remote meter reading system. The system selects trusted technology such as, the identity authentication, integrity verifying, and data protection. By the experiments, it is proved that the remote meter reading system of the heat meter can be used to verify the feasibility of the technology, and verify the practicability and operability of data protection technology.

  6. Analytic evaluation of a new glucose meter system in 15 different critical care settings.

    Science.gov (United States)

    Mitsios, John V; Ashby, Lori A; Haverstick, Doris M; Bruns, David E; Scott, Mitchell G

    2013-09-01

    Maintaining appropriate glycemic control in critically ill patients reduces morbidity and mortality. The use of point-of-care (POC) glucose devices is necessary to obtain rapid results at the patient's bedside. However, the devices should be thoroughly tested in the intended population before implementation. The use of POC glucose meters in critically ill patients has been questioned both in the literature and by regulatory agencies. The aim of this study was to determine if the ACCU-CHEK® Inform II system (Roche Diagnostics) POC glucose meter demonstrated the desired accuracy and precision, as defined by Clinical and Laboratory Standards Institute guideline POCT12-A3, in a large number of critically ill patients from multiple intensive care settings at two academic medical centers. A total of 1200 whole blood meter results from 600 patients were compared with central laboratory plasma values. Whole blood aliquots from venous samples were used to obtain duplicate meter results with the remaining sample being processed to obtain plasma for central laboratory testing within 5 min of meter testing. A total of 1185 (98.8%) of the new meter's glucose values were within ± 12.5% (± 12 mg/dl for values ≥ 100 mg/dl) of the comparative laboratory glucose values, and 1198 (99.8%) were within ± 20% (± 20 mg/dl for values meter system appears to have sufficient analytic accuracy for use in critically ill patients. © 2013 Diabetes Technology Society.

  7. Metering: EU policy and implications for fuel poor households

    International Nuclear Information System (INIS)

    Darby, Sarah J.

    2012-01-01

    Fuel poverty is a function of household energy consumption, income, and the cost of delivered energy. The paper discusses ways in which current EU policy on the development of ‘smart’ metering could affect fuel poor households. The main focus is on developments in electricity metering and the development of ‘active demand’ and smart grids, so that demand can be matched closely with available supply. Advances in metering and related technologies open the way to time-of-use charging, easier switching between suppliers and between credit payment and prepayment, direct load control of some end-uses by the utility, greater scope for microgeneration, and improved consumption feedback for customers. These options open up both uncertainties and risks. The paper offers definitions and discussion of various functions of smart metering, summarizes the EU policy background, and considers some possible equity implications of rolling out a new generation of meters. There follows an assessment of potential implications to the fuel poor of changes to metering, based on a review of the literature on energy feedback, tariffing, and supplier–customer relationships. Much of the discussion is based on the UK experience, with examples from other EU member states and, where appropriate, from other parts of the world. - Highlights: ► Smart meters are part of general upgrading of electricity and gas networks. ► EU policy is to roll out the meters to 80%+ of the population by 2020. ► Improved feedback and prepayment metering may benefit the fuel poor. ► Remote disconnection and data privacy are issues for all consumers. ► We need careful assessment of potential gains and losses to the fuel poor.

  8. EMMNet: Sensor Networking for Electricity Meter Monitoring

    Directory of Open Access Journals (Sweden)

    Zhi-Ting Lin

    2010-06-01

    Full Text Available Smart sensors are emerging as a promising technology for a large number of application domains. This paper presents a collection of requirements and guidelines that serve as a basis for a general smart sensor architecture to monitor electricity meters. It also presents an electricity meter monitoring network, named EMMNet, comprised of data collectors, data concentrators, hand-held devices, a centralized server, and clients. EMMNet provides long-distance communication capabilities, which make it suitable suitable for complex urban environments. In addition, the operational cost of EMMNet is low, compared with other existing remote meter monitoring systems based on GPRS. A new dynamic tree protocol based on the application requirements which can significantly improve the reliability of the network is also proposed. We are currently conducting tests on five networks and investigating network problems for further improvements. Evaluation results indicate that EMMNet enhances the efficiency and accuracy in the reading, recording, and calibration of electricity meters.

  9. EMMNet: sensor networking for electricity meter monitoring.

    Science.gov (United States)

    Lin, Zhi-Ting; Zheng, Jie; Ji, Yu-Sheng; Zhao, Bao-Hua; Qu, Yu-Gui; Huang, Xu-Dong; Jiang, Xiu-Fang

    2010-01-01

    Smart sensors are emerging as a promising technology for a large number of application domains. This paper presents a collection of requirements and guidelines that serve as a basis for a general smart sensor architecture to monitor electricity meters. It also presents an electricity meter monitoring network, named EMMNet, comprised of data collectors, data concentrators, hand-held devices, a centralized server, and clients. EMMNet provides long-distance communication capabilities, which make it suitable suitable for complex urban environments. In addition, the operational cost of EMMNet is low, compared with other existing remote meter monitoring systems based on GPRS. A new dynamic tree protocol based on the application requirements which can significantly improve the reliability of the network is also proposed. We are currently conducting tests on five networks and investigating network problems for further improvements. Evaluation results indicate that EMMNet enhances the efficiency and accuracy in the reading, recording, and calibration of electricity meters.

  10. Look at the Beat, Feel the Meter: Top-Down Effects of Meter Induction on Auditory and Visual Modalities.

    Science.gov (United States)

    Celma-Miralles, Alexandre; de Menezes, Robert F; Toro, Juan M

    2016-01-01

    Recent research has demonstrated top-down effects on meter induction in the auditory modality. However, little is known about these effects in the visual domain, especially without the involvement of motor acts such as tapping. In the present study, we aim to assess whether the projection of meter on auditory beats is also present in the visual domain. We asked 16 musicians to internally project binary (i.e., a strong-weak pattern) and ternary (i.e., a strong-weak-weak pattern) meter onto separate, but analog, visual and auditory isochronous stimuli. Participants were presented with sequences of tones or blinking circular shapes (i.e., flashes) at 2.4 Hz while their electrophysiological responses were recorded. A frequency analysis of the elicited steady-state evoked potentials allowed us to compare the frequencies of the beat (2.4 Hz), its first harmonic (4.8 Hz), the binary subharmonic (1.2 Hz), and the ternary subharmonic (0.8 Hz) within and across modalities. Taking the amplitude spectra into account, we observed an enhancement of the amplitude at 0.8 Hz in the ternary condition for both modalities, suggesting meter induction across modalities. There was an interaction between modality and voltage at 2.4 and 4.8 Hz. Looking at the power spectra, we also observed significant differences from zero in the auditory, but not in the visual, binary condition at 1.2 Hz. These findings suggest that meter processing is modulated by top-down mechanisms that interact with our perception of rhythmic events and that such modulation can also be found in the visual domain. The reported cross-modal effects of meter may shed light on the origins of our timing mechanisms, partially developed in primates and allowing humans to synchronize across modalities accurately.

  11. Look at the Beat, Feel the Meter: Top–Down Effects of Meter Induction on Auditory and Visual Modalities

    Science.gov (United States)

    Celma-Miralles, Alexandre; de Menezes, Robert F.; Toro, Juan M.

    2016-01-01

    Recent research has demonstrated top–down effects on meter induction in the auditory modality. However, little is known about these effects in the visual domain, especially without the involvement of motor acts such as tapping. In the present study, we aim to assess whether the projection of meter on auditory beats is also present in the visual domain. We asked 16 musicians to internally project binary (i.e., a strong-weak pattern) and ternary (i.e., a strong-weak-weak pattern) meter onto separate, but analog, visual and auditory isochronous stimuli. Participants were presented with sequences of tones or blinking circular shapes (i.e., flashes) at 2.4 Hz while their electrophysiological responses were recorded. A frequency analysis of the elicited steady-state evoked potentials allowed us to compare the frequencies of the beat (2.4 Hz), its first harmonic (4.8 Hz), the binary subharmonic (1.2 Hz), and the ternary subharmonic (0.8 Hz) within and across modalities. Taking the amplitude spectra into account, we observed an enhancement of the amplitude at 0.8 Hz in the ternary condition for both modalities, suggesting meter induction across modalities. There was an interaction between modality and voltage at 2.4 and 4.8 Hz. Looking at the power spectra, we also observed significant differences from zero in the auditory, but not in the visual, binary condition at 1.2 Hz. These findings suggest that meter processing is modulated by top–down mechanisms that interact with our perception of rhythmic events and that such modulation can also be found in the visual domain. The reported cross-modal effects of meter may shed light on the origins of our timing mechanisms, partially developed in primates and allowing humans to synchronize across modalities accurately. PMID:27047358

  12. Look at the Beat, Feel the Meter:Top-down Effects of Meter Induction on Auditory and Visual Modalities

    Directory of Open Access Journals (Sweden)

    Alexandre eCelma-Miralles

    2016-03-01

    Full Text Available Recent research has demonstrated top-down effects on meter induction in the auditory modality. However, little is known about these effects in the visual domain, especially without the involvement of motor acts such as tapping. In the present study, we aim to assess whether the projection of meter on auditory beats is also present in the visual domain. We asked sixteen musicians to internally project binary (i.e. a strong-weak pattern and ternary (i.e. a strong-weak-weak pattern meter onto separate, but analogue, visual and auditory isochronous stimuli. Participants were presented with sequences of tones or blinking circular shapes (i.e. flashes at 2.4 Hz while their electrophysiological responses were recorded. A frequency analysis of the elicited steady-state evoked potentials allowed us to compare the frequencies of the beat (2.4 Hz, its first harmonic (4.8 Hz, the binary subharmonic (1.2 Hz, and ternary subharmonic (0.8 Hz within and across modalities. Taking the amplitude spectra into account, we observed an enhancement of the amplitude at 0.8 Hz in the ternary condition for both modalities, suggesting meter induction across modalities. There was an interaction between modality and voltage at 2.4 and 4.8 Hz. Looking at the power spectra, we also observed significant differences from zero in the auditory, but not in the visual, binary condition at 1.2 Hz. These findings suggest that meter processing is modulated by top-down mechanisms that interact with our perception of rhythmic events and that such modulation can also be found in the visual domain. The reported cross-modal effects of meter may shed light on the origins of our timing mechanisms, partially developed in primates and allowing humans to synchronize across modalities accurately.

  13. KVP meter errors induced by plastic wrap

    International Nuclear Information System (INIS)

    Jefferies, D.; Morris, J.W.; White, V.P.

    1991-01-01

    The purpose of this study was to determine whether erroneous kVp meter readings, induced by plastic wrap, affected the actual kVp (output) of a dental X-ray machine. To evaluate the effect of plastic wrap on dental X-ray machine kVp meters, a radiation output device was used to measure output in mR/ma.s. An intraoral dental X-ray unit (S.S. White Model number-sign 90W) was used to make the exposures. First, the kVp meter was not covered with plastic wrap and output readings were recorded at various kVp settings with the milliamperage and time held constant. Secondly, the same kVp settings were selected before the plastic wrap was placed. Milliamperage and time were again held to the same constant. The X-ray console was then covered with plastic wrap prior to measuring the output for each kVp. The wrap possessed a static charge. This charge induced erroneous kVp meter readings. Out-put readings at the various induced kVp settings were then recorded. A kVp of 50 with no wrap present resulted in the same output as a kVp of 50 induced to read 40 or 60 kVp by the presence of wrap. Similar results were obtained at other kVp settings. This indicates that the plastic wrap influences only the kVp meter needle and not the actual kilovoltage of the X-ray machine. Dental X-ray machine operators should select kVp meter readings prior to placing plastic wrap and should not adjust initial settings if the meter is deflected later by the presence of wrap. The use of such a procedure will result in proper exposures, fewer retakes, and less patient radiation. If plastic wrap leads to consistent exposure errors, clinicians may wish to use a 0.5% sodium hypochlorite disinfectant as an alternative to the barrier technique

  14. The performance of a glucose-ketone meter in the diagnosis of diabetic ketoacidosis in patients with type 2 diabetes in the emergency room.

    Science.gov (United States)

    Voulgari, Christina; Tentolouris, Nicholas

    2010-07-01

    Diabetic ketoacidosis (DKA) is a serious metabolic complication. One of its precipitating causes is insulin omission. DKA requires early diagnosis and strict glucose control, which increases the use of glucose meters in the Emergency Room (ER). We aimed to determine the performance of a glucose-ketone meter in the diagnosis of DKA. From 450 type 2 diabetes mellitus insulin-treated patients attending the ER with a capillary glucose level >13.9 mmol/L, 50 patients (26 men and 24 women, mean age 60.2 +/- 8.2 years) had DKA. Capillary glucose and beta-hydroxybutyrate (beta-OHB) were measured with the Precision-Xtra device (Abbott Laboratories, Abingdon, UK). Serum glucose and biochemical parameters were measured on an automatic analyzer; serum beta-OHB was determined using an enzymatic end-point spectrophotometric method. Urine ketones were determined using a semiquantitative assay (Ketodiastix, Bayer Diagnostics, Stoke Poges, Slough, UK). Serum and capillary beta-OHB values were highly correlated (r = 0.99, P 3.0 mmol/L) had the highest performance (sensitivity 99.87%, specificity 92.89%, positive predictive value 92.89%) for the diagnosis of DKA compared with serum ketonemia (sensitivity 90.45%, specificity 88.65%, positive predictive value 87.76%) or ketonuria (sensitivity 89.89%, specificity 52.73%, positive predictive value 41.87%). Implementation of measures such as home glucose and ketone monitoring can possibly decrease the number of hospital admissions due to DKA.

  15. Integrating an Embedded System within a Microwave Moisture Meter

    Science.gov (United States)

    In this paper, the conversion of a PC or laptop-controlled microwave moisture meter to a stand-alone meter hosting its own embedded system is discussed. The moisture meter uses low-power microwaves to measure the attenuation and phase shift of the sample, from which the dielectric properties are cal...

  16. 21 CFR 868.1860 - Peak-flow meter for spirometry.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Peak-flow meter for spirometry. 868.1860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1860 Peak-flow meter for spirometry. (a) Identification. A peak-flow meter for spirometry is a device used to measure a patient's...

  17. Customer-economics of residential photovoltaic systems (Part 1): The impact of high renewable energy penetrations on electricity bill savings with net metering

    International Nuclear Information System (INIS)

    Darghouth, Naïm R.; Barbose, Galen; Wiser, Ryan H.

    2014-01-01

    Residential photovoltaic (PV) systems in the US are often compensated at the customer's underlying retail electricity rate through net metering. Given the uncertainty in future retail rates and the inherent links between rates and the customer–economics of behind-the-meter PV, there is growing interest in understanding how potential changes in rates may impact the value of bill savings from PV. In this article, we first use a production cost and capacity expansion model to project California hourly wholesale electricity market prices under two potential electricity market scenarios, including a reference and a 33% renewables scenario. Second, based on the wholesale electricity market prices generated by the model, we develop retail rates (i.e., flat, time-of-use, and real-time pricing) for each future scenario based on standard retail rate design principles. Finally, based on these retail rates, the bill savings from PV is estimated for 226 California residential customers under two types of net metering, for each scenario. We find that high renewable penetrations can drive substantial changes in residential retail rates and that these changes, together with variations in retail rate structures and PV compensation mechanisms, interact to place substantial uncertainty on the future value of bill savings from residential PV. - Highlights: • We investigate the impact of high renewables on customer economics of solar. • We model three types of residential retail electricity rates. • Based on the rates, we calculate the bill savings from photovoltaic (PV) generation. • High renewables penetration can lead to lower bill savings with time-varying rates. • There is substantial uncertainty in the future bill savings from residential PV

  18. Performance of a Modern Glucose Meter in ICU and General Hospital Inpatients: 3 Years of Real-World Paired Meter and Central Laboratory Results.

    Science.gov (United States)

    Zhang, Ray; Isakow, Warren; Kollef, Marin H; Scott, Mitchell G

    2017-09-01

    Due to accuracy concerns, the Food and Drug Administration issued guidances to manufacturers that resulted in Center for Medicare and Medicaid Services stating that the use of meters in critically ill patients is "off-label" and constitutes "high complexity" testing. This is causing significant workflow problems in ICUs nationally. We wished to determine whether real-world accuracy of modern glucose meters is worse in ICU patients compared with non-ICU inpatients. We reviewed glucose results over the preceding 3 years, comparing results from paired glucose meter and central laboratory tests performed within 60 minutes of each other in ICU versus non-ICU settings. Seven ICU and 30 non-ICU wards at a 1,300-bed academic hospital in the United States. A total of 14,763 general medicine/surgery inpatients and 20,970 ICU inpatients. None. Compared meter results with near simultaneously performed laboratory results from the same patient by applying the 2016 U.S. Food and Drug Administration accuracy criteria, determining mean absolute relative difference and examining where paired results fell within the Parkes consensus error grid zones. A higher percentage of glucose meter results from ICUs than from non-ICUs passed 2016 Food and Drug Administration accuracy criteria (p meter results with laboratory results. At 1 minute, no meter result from ICUs posed dangerous or significant risk by error grid analysis, whereas at 10 minutes, less than 0.1% of ICU meter results did, which was not statistically different from non-ICU results. Real-world accuracy of modern glucose meters is at least as accurate in the ICU setting as in the non-ICU setting at our institution.

  19. Guanabara Bay and Pecem LNG flexible metering systems

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Vinicus Roberto C.; Carvalho, Gustavo L.A.; Bruel, Edson L.; Santana, Jose P.C. de; Vidal, Lud C.C.N. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2009-12-19

    This work presents to the community the metering systems installed in the Liquefied Natural (LNG) Gas Flexible Terminals of the Pecem Port and Guanabara Bay. A brief description of the Terminals facilities and its operation is firstly made to provide a background of the systems discussed. Then, the LNG custody transfer metering system, the operational control metering system, the energy balance of the LNG transferring system and the Natural Gas custody transfer metering system - that are our systems of interest - are described in detail. It is intended to use the philosophy adopted in the Guanabara Bay and Pecem Flexible Terminals design as a standard to future installations, integrated with improvements brought by the operation experience that will be obtained in those terminals. (author)

  20. [Evaluation of Optium Xceed (Abbott) and One Touch Ultra (Lifescan) glucose meters].

    Science.gov (United States)

    Coyne, S; Lacour, B; Hennequin-Le Meur, C

    2008-01-01

    In order to build a continuous quality improvement approach for control of glucose meters in clinical divisions at Necker-Enfants Malades hospital, the analytical performances (precision and accuracy) of 2 glucose meters have been evaluated in our laboratory according to SFBC recommendations. Fifty-six heparinized whole blood specimens from patients and thirty-nine from healthy volunteers were analyzed on each of the two meters and compared to plasma glucose measurement on the Roche Hitachi 917 system. The correlation coefficient was 0.938 for Optium Xceed and 0.911 for One Touch Ultra. However, 14.7% and 18.9% of the results (n = 95) for respectively Optium Xceed and One Touch Ultra were discordant, i.e. higher than a 20% difference compared to reference blood glucose concentrations. Inaccuracy was more important for low glucose concentrations (glucose concentrations. Capillary blood glucose concentrations must therefore be interpreted with caution concerning the diagnosis of hypoglycemia and treatment of unstable patients. Moreover, quality control of glucose meters (blood glucose determinations concurrently at bedside and in the laboratory) is difficult to perform. It also raises questions about the responsibility of "point-of-care testing", an area still subject to discussion.

  1. The disc pasture meter: Possible applications in grazing management.

    African Journals Online (AJOL)

    The disc meter is a simple inexpensive instrument which may be used to make rapid yield estimates of standing forage. Linear regression relationships between meter reading and pasture dry matter yield are usually fairly good, but these may be affected by a number of different factors. The meter should therefore be ...

  2. Reliability of 4-meter and 10-meter walk tests after lower extremity surgery.

    Science.gov (United States)

    Unver, Bayram; Baris, Refik Hilmi; Yuksel, Ertugrul; Cekmece, Senol; Kalkan, Serpil; Karatosun, Vasfi

    2017-12-01

    To investigate the test-retest reliability of the 4-meter walk test (4 MWT) and 10-meter walk test (10 MWT) in patients undergoing lower extremity surgery during inpatient rehabilitation. In all, 102 patients with total hip arthroplasty (THA), total knee arthroplasty (TKA), lower extremity fracture (LEF) and soft tissue operation were recruited. Patients performed two 4 MWT and two 10 MWT trials on the same day. The same researcher performed all the measurements to avoid inter-rater variability. The 4 MWT and 10 MWT were shown to have excellent test-retest reliability. The ICCs for the 4 MWT and 10 MWT were found as 0.94 and 0.95, respectively. The SEMs for the 4 MWT and 10 MWT were 2.0 and 5.5 seconds, respectively. The smallest real difference at the 95% confidence level (SRD95) was 5.5 seconds for the 4 MWT and 12.2 seconds for 10 MWT and SRD95 percentage was 31.2 for the 4 MWT and 28.5 for the 10 MWT. Both the 4 MWT and the 10 MWT have excellent reliability in patients undergoing lower extremity surgery such as TKA, THA, LEF and soft tissue operation during inpatient rehabilitation. Clinicians and researchers can be confident that changes above the SRD95s for the different patient groups, for both sexes and with regard to weight-bearing status, represent a real clinical change in rehabilitation process. Implications for Rehabilitation The 4 MWT and the 10 MWT are simple methods and were also shown to be reliable measurement methods in many patient groups. This study illustrates that the test-retest reliability of the 4 MWT and 10 MWT are excellent in patients undergoing lower extremity surgery during inpatient rehabilitation (ICC: 0.94 for 4 MWT, ICC: 0.95 for 10 MWT). Clinicians and researchers can be confident that changes above the SRD95s for the different patient groups, for both sexes and with regard to weight-bearing status represent a real clinical change in rehabilitation process.

  3. Hydrogen meter for service in liquid sodium

    International Nuclear Information System (INIS)

    McCown, J.J.

    1983-11-01

    This standard establishes the requirements for the design, materials, fabrication, quality assurance, examination, and acceptance testing of a hydrogen meter and auxiliary equipment for use in radioactive or nonradioactive liquid sodium service. The meter shall provide a continuous and accurate indication of the hydrogen impurity concentration over the range 0.03 to 10 ppM hydrogen in sodium at temperatures between 800 and 1000 0 F (427 and 538 0 C). The meter may also be used to rapidly monitor changes in hydrogen concentration, over the same concentration range, and, therefore can be used as a sensor for sodium-water reactions in LMFBR steam generators

  4. Additional functions of remotely read kWh-meters

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P. [VTT Energy, Espoo (Finland); Vehvilaeinen, S. [Mittrix Oy (Finland); Rantanen, J. [Helsinki Energy Board, Helsinki (Finland)

    1996-12-31

    In this presentation the possibilities to include new applications into remotely read smart kWh-meters are considered. New electronic meters can measure various electric quantities and have some extra calculating capacity. So they can be used to provide functions that distribution automation and the customer need and thus share the costs. Some applications like monitoring the state of the distribution network or locating faults are only for the utility, but many applications also need an interface to the customer or his automation system. Among those are monitoring the quality of electricity, estimating load curves, applying dynamic tariffs and selling electricity and accounting. As a special item, the continuous monitoring of the quality of electricity is discussed. This includes voltage levels, total distortion, asymmetry and so on. If such a kWh-meter indicates quality problems the situation can be detected with a suitable portable quality meter. The poor quality can be detected before it causes harm to equipment owned by the customers or the power distribution company. This presentation also presents a prototype of such a quality monitoring kWh-meter

  5. Additional functions of remotely read kWh-meters

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P [VTT Energy, Espoo (Finland); Vehvilaeinen, S [Mittrix Oy (Finland); Rantanen, J [Helsinki Energy Board, Helsinki (Finland)

    1997-12-31

    In this presentation the possibilities to include new applications into remotely read smart kWh-meters are considered. New electronic meters can measure various electric quantities and have some extra calculating capacity. So they can be used to provide functions that distribution automation and the customer need and thus share the costs. Some applications like monitoring the state of the distribution network or locating faults are only for the utility, but many applications also need an interface to the customer or his automation system. Among those are monitoring the quality of electricity, estimating load curves, applying dynamic tariffs and selling electricity and accounting. As a special item, the continuous monitoring of the quality of electricity is discussed. This includes voltage levels, total distortion, asymmetry and so on. If such a kWh-meter indicates quality problems the situation can be detected with a suitable portable quality meter. The poor quality can be detected before it causes harm to equipment owned by the customers or the power distribution company. This presentation also presents a prototype of such a quality monitoring kWh-meter

  6. Design and Implementation of Pointer-Type Multi Meters Intelligent Recognition Device Based on ARM Platform

    Science.gov (United States)

    Cui, Yang; Luo, Wang; Fan, Qiang; Peng, Qiwei; Cai, Yiting; Yao, Yiyang; Xu, Changfu

    2018-01-01

    This paper adopts a low power consumption ARM Hisilicon mobile processing platform and OV4689 camera, combined with a new skeleton extraction based on distance transform algorithm and the improved Hough algorithm for multi meters real-time reading. The design and implementation of the device were completed. Experimental results shows that The average error of measurement was 0.005MPa, and the average reading time was 5s. The device had good stability and high accuracy which meets the needs of practical application.

  7. Enhanced Operation of Electricity Distribution Grids Through Smart Metering PLC Network Monitoring, Analysis and Grid Conditioning

    Directory of Open Access Journals (Sweden)

    Iker Urrutia

    2013-01-01

    Full Text Available Low Voltage (LV electricity distribution grid operations can be improved through a combination of new smart metering systems’ capabilities based on real time Power Line Communications (PLC and LV grid topology mapping. This paper presents two novel contributions. The first one is a new methodology developed for smart metering PLC network monitoring and analysis. It can be used to obtain relevant information from the grid, thus adding value to existing smart metering deployments and facilitating utility operational activities. A second contribution describes grid conditioning used to obtain LV feeder and phase identification of all connected smart electric meters. Real time availability of such information may help utilities with grid planning, fault location and a more accurate point of supply management.

  8. Performance evaluation of cognitive radio in advanced metering infrastructure communication

    Science.gov (United States)

    Hiew, Yik-Kuan; Mohd Aripin, Norazizah; Din, Norashidah Md

    2016-03-01

    Smart grid is an intelligent electricity grid system. A reliable two-way communication system is required to transmit both critical and non-critical smart grid data. However, it is difficult to locate a huge chunk of dedicated spectrum for smart grid communications. Hence, cognitive radio based communication is applied. Cognitive radio allows smart grid users to access licensed spectrums opportunistically with the constraint of not causing harmful interference to licensed users. In this paper, a cognitive radio based smart grid communication framework is proposed. Smart grid framework consists of Home Area Network (HAN) and Advanced Metering Infrastructure (AMI), while AMI is made up of Neighborhood Area Network (NAN) and Wide Area Network (WAN). In this paper, the authors only report the findings for AMI communication. AMI is smart grid domain that comprises smart meters, data aggregator unit, and billing center. Meter data are collected by smart meters and transmitted to data aggregator unit by using cognitive 802.11 technique; data aggregator unit then relays the data to billing center using cognitive WiMAX and TV white space. The performance of cognitive radio in AMI communication is investigated using Network Simulator 2. Simulation results show that cognitive radio improves the latency and throughput performances of AMI. Besides, cognitive radio also improves spectrum utilization efficiency of WiMAX band from 5.92% to 9.24% and duty cycle of TV band from 6.6% to 10.77%.

  9. Instrument evaluation no. 8. Nuclear Enterprises beta/gamma dose rate meter type 0500

    International Nuclear Information System (INIS)

    Iles, W.J.; Burgess, P.H.; Callowhill, K.

    1977-04-01

    This instrument is a portable, battery powered survey meter covering the dose rate range from 0 to 10,000 mrad h -1 and the dose range 0 to 1000 mrad. The instrument was designed to measure X and γ-radiation dose and dose rate over a wide energy range, and also β-radiation dose and dose rate. An unsealed ionisation chamber is used as the detector. The aluminised melinex thin end window of the chamber is provided with a detachable plastic end cap. The calibration plane of the chamber is indicated by a cross on the side of the instrument. The information is given under the following headings: facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; summary of performance; conclusions. (U.K.)

  10. Monitoring of prestressed concrete pressure vessels. II. performance of selected concrete embedment strain meters under normal and extreme environmental conditions

    International Nuclear Information System (INIS)

    Naus, D.J.; Hurtt, C.C.

    1978-10-01

    Unique types of instrumentation are used in prestressed concrete pressure vessels (PCPVs) to measure strains, stresses, deflections, prestressing forces, moisture content, temperatures, and possibly cracking. Their primary purpose is to monitor these complex structures throughout their 20- to 30-year operating lifetime in order to provide continuing assurance of their reliability and safety. Numerous concrete embedment instrumentation systems are available commercially. Since this instrumentation is important in providing continuing assurance of satisfactory performance of PCPVs, the information provided must be reliable. Therefore, laboratory studies were conducted to evaluate the reliability of these commercially available instrumentation systems. This report, the second in a series related to instrumentation embedded in concrete, presents performance-reliability data for 13 types of selected concrete embedment strain meters which were subjected to a variety of loading environments, including unloaded, thermally loaded, simulated PCPV, and extreme environments. Although only a limited number of meters of each type were tested in any one test series, the composite results of the investigation indicate that the majority of these meters would not be able to provide reliable data throughout the 20- to 30-year anticipated operating life of a PCPV. Specific conclusions drawn from the study are: (1) Improved corrosion-resistant materials and sealing techniques should be developed for meters that are to be used in PCPV environments. (2) There is a need for the development of meters that are capable of surviving in concretes where temperatures in excess of 66 0 C are present for extended periods of time. (3) Research should be conducted on other measurement techniques, such as inductance, capacitance, and fluidics

  11. Physical requirements for measurement of radiation dose and their relationship to personnel dose meter design and use

    International Nuclear Information System (INIS)

    Chabot, G.E. Jr.; Jimenez, M.A.; Skrable, K.W.

    1978-01-01

    This paper stems from the concerns of the authors with both the design of current personnel dose meters and the interpretation of dose information from them in light of the actual physical requirements to measure dose. These concerns have been reinforced and extended following a comparative study of the responses of particular TLD and film systems and as the result of a recent national survey on personnel dosimetry conducted by the authors. Among the major points discussed are the systems available for penetrating and shallow dose assessment, dose meter calibration, the measurement and interpretation of skin dose, and the deficiencies of neutron albedo dose meters for routine personnel use. Calibration considerations address the questions of whether or not a phantom should be used and the difference in interpretation of responses with and without a phantom; the relationship between calculated and measured doses; and electronic equilibrium considerations in the measurement of photon doses. Matters of importance in relation to skin dose measurement include techniques in use to interpret skin dose from dose meter response; the appropriateness of evaluation of the surface dose to the live skin layer versus the average dose to the live skin layer and the limitations and requirements on dose meter design with respect to the dose being evaluated; and the significance of dose meter response in relationship to currently used beta calibration standards. Regarding the use of TLD albedo type neutron dose meters currently available, considerations are extended to the strong energy spectral dependence of the dose meter response and the possibility of making significant over or underestimations of neutron dose equivalent, depending on the calibration techniques used and the spectral quality encountered. (author)

  12. Optimization on Measurement Method for Neutron Moisture Meter

    International Nuclear Information System (INIS)

    Gong Yalin; Wu Zhiqiang; Li Yanfeng; Wang Wei; Song Qingfeng; Liu Hui; Wei Xiaoyun; Zhao Zhonghua

    2010-01-01

    When the water in the measured material is nonuniformity, the measured results of the neutron moisture meter in the field may have errors, so the measured errors of the moisture meter associated with the water nonuniformity in material were simulated by Monte Carlo method. A new measurement method of moisture meter named 'transmission plus scatter' was put forward. The experiment results show that the new measurement method can reduce the error even if the water in the material is nonuniformity. (authors)

  13. Evolution, calibration, and operational characteristics of the two-dimensional test section of the Langley 0.3-meter transonic cryogenic tunnel

    Science.gov (United States)

    Ladson, Charles L.; Ray, Edward J.

    1987-01-01

    Presented is a review of the development of the world's first cryogenic pressure tunnel, the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT). Descriptions of the instrumentation, data acquisition systems, and physical features of the two-dimensional 8- by 24-in, (20.32 by 60.96 cm) and advanced 13- by 13-in (33.02 by 33.02 cm) adaptive-wall test-section inserts of the 0.3-m TCT are included. Basic tunnel-empty Mach number distributions, stagnation temperature distributions, and power requirements are included. The Mach number capability of the facility is from about 0.20 to 0.90. Stagnation pressure can be varied from about 80 to 327 K.

  14. Solutions For Smart Metering Under Harsh Environmental Condicions

    Directory of Open Access Journals (Sweden)

    Kunicina N.

    2015-02-01

    Full Text Available The described case study concerns application of wireless sensor networks to the smart control of power supply substations. The solution proposed for metering is based on the modular principle and has been tested in the intersystem communication paradigm using selectable interface modules (IEEE 802.3, ISM radio interface, GSM/GPRS. The solution modularity gives 7 % savings of maintenance costs. The developed solution can be applied to the control of different critical infrastructure networks using adapted modules. The proposed smart metering is suitable for outdoor installation, indoor industrial installations, operation under electromagnetic pollution, temperature and humidity impact. The results of tests have shown a good electromagnetic compatibility of the prototype meter with other electronic devices. The metering procedure is exemplified by operation of a testing company's workers under harsh environmental conditions.

  15. Privacy-Preserving Smart Metering with Authentication in a Smart Grid

    Directory of Open Access Journals (Sweden)

    Jun Beom Hur

    2015-12-01

    Full Text Available The traditional security objectives of smart grids have been availability, integrity, and confidentiality. However, as the grids incorporate smart metering and load management, user and corporate privacy is increasingly becoming an issue in smart grid networks. Although transmitting current power consumption levels to the supplier or utility from each smart meter at short intervals has an advantage for the electricity supplier’s planning and management purposes, it threatens user privacy by disclosing fine-grained consumption data and usage behavior to utility providers. In this study, we propose a distributed incremental data aggregation scheme where all smart meters on an aggregation path are involved in routing the data from the source meter to the collection unit. User privacy is preserved by symmetric homomorphic encryption, which allows smart meters to participate in the aggregation without seeing any intermediate or final result. Aggregated data is further integrated with an aggregate signature to achieve data integrity and smart meter authentication in such a way that dishonest or fake smart meters cannot falsify data en route. Only the collection unit can obtain the aggregated data and verify its integrity while the individual plain data are not exposed to the collection unit. Therefore, user privacy and security are improved for the smart metering in a smart grid network.

  16. Lessons from wet gas flow metering systems using differential measurements devices: Testing and flow modelling results

    Energy Technology Data Exchange (ETDEWEB)

    Cazin, J.; Couput, J.P.; Dudezert, C. et al

    2005-07-01

    A significant number of wet gas meters used for high GVF and very high GVF are based on differential pressure measurements. Recent high pressure tests performed on a variety of different DP devices on different flow loops are presented. Application of existing correlations is discussed for several DP devices including Venturi meters. For Venturi meters, deviations vary from 9% when using the Murdock correlation to less than 3 % with physical based models. The use of DP system in a large domain of conditions (Water Liquid Ratio) especially for liquid estimation will require information on the WLR This obviously raises the question of the gas and liquid flow metering accuracy in wet gas meters and highlight needs to understand AP systems behaviour in wet gas flows (annular / mist / annular mist). As an example, experimental results obtained on the influence of liquid film characteristics on a Venturi meter are presented. Visualizations of the film upstream and inside the Venturi meter are shown. They are completed by film characterization. The AP measurements indicate that for a same Lockhart Martinelli parameter, the characteristics of the two phase flow have a major influence on the correlation coefficient. A 1D model is defined and the results are compared with the experiments. These results indicate that the flow regime influences the AP measurements and that a better modelling of the flow phenomena is needed even for allocation purposes. Based on that, lessons and way forward in wet gas metering systems improvement for allocation and well metering are discussed and proposed. (author) (tk)

  17. IMPORTANT: Fluke is recalling Digital Clamp Meters

    CERN Multimedia

    2013-01-01

    Fluke is voluntarily recalling four models of Digital Clamp Meters: Fluke 373, 374, 375 and 376. If you own one of these clamp meters, please stop using it and send it back to Fluke for repair even if you have not experienced problems.   Description of the problem: "The printed circuit assembly may not be properly fastened to the test lead input jack. This may result in inaccurate voltage readings, including a low or no-voltage reading on a circuit energised with a hazardous voltage, presenting a shock, electrocution or thermal burn hazard." To determine if your clamp meter is affected by this recall notice, and for more information, click here.

  18. A tool to increase information-processing capacity for consumer water meter data

    Directory of Open Access Journals (Sweden)

    Heinz E. Jacobs

    2012-02-01

    Full Text Available Background: Water service providers invoice most South African urban consumers for the water they use every month. A secure treasury system generates water invoices at municipalities’ financial departments. Information about the water usage of customers initially comes from reading the water meters, usually located in gardens near the front boundaries of properties. Until as recently as 1990, the main purpose of the water meter readings was to generate invoices for water usage. There are various treasury systems for this purpose.Objective: The objective of this research article was to describe the development of Swift, a locally developed software tool for analysing water meter data from an information management perspective, which engineers in the water field generally use, and to assess critically the influence of Swift on published research and industry. This article focuses on water usage and the challenge of data interchange and extraction as issues that various industries face.Method: This article presents the first detailed report on Swift. It uses a detailed knowledge review and presents and summarises the findings chronologically.Results: The water meter data flow path used to be quite simple. The risk of breaches in confidentiality was limited. Technological advances over the years have led to additional knowledge coming from the same water meter readings with subsequent research outputs. However, there are also complicated data flow paths and increased risks. Users have used Swift to analyse more than two million consumers’ water meter readings to date. Studies have culminated in 10 peer-reviewed journal articles using the data. Seven of them were in the last five years.Conclusion: Swift-based data was the basis of various research studies in the past decade. Practical guidelines in the civil engineering fraternity for estimating water use in South Africa have incorporated knowledge from these studies. Developments after 1995 have

  19. Clinical utility of Abbott Precision Xceed Pro® ketone meter in diabetic patients.

    Science.gov (United States)

    Yu, Hoi-Ying Elsie; Agus, Michael; Kellogg, Mark D

    2011-11-01

    Diagnosis and management of diabetic ketoacidosis (DKA) often rely on the measurement of urine ketones along with blood glucose, anion gap, and pH. These values, however, do not reliably reflect the severity of ketoacidosis. The Abbott Precision Xceed Pro® meter is an FDA-approved device that quantitatively measures β-hydroxybutyrate (BOH) in whole blood. This study was undertaken to determine whether the ketone meter meets the analytical criteria to aid DKA diagnosis and management in the hospital. 54 heparinized venous whole blood BOH concentrations from 27 diabetic patients were measured by the Abbott meter, and compared with the plasma BOH concentrations measured with Stanbio reagent (reference method). Measurements were done in the hospital central laboratory. Of the 54 pairs of specimens analyzed, 17 pairs displayed a difference of >15% between the two methods. Nearly all discrepant points occurred when BOH >5 mmol/L (reference method). Linearity evaluation revealed that the meter is not linear from 0.0 to 8.0 mmol/L, contrary to the claim by the manufacturer. Further, we identified acetoacetate, a metabolite commonly present in DKA patients, as a potential interfering substance for the meter BOH measurement. BOH measurements by the Abbott meter up to 3 mmol/L correlate well with the reference method, but become discrepant above that point. While this characteristic may be useful in the diagnosis of DKA, it may not allow clinicians to serially follow the response to therapy in hospitalized DKA patients with BOH values greater than 5 mmol/L (reference method). © 2011 John Wiley & Sons A/S.

  20. Some problems in calibrating surface contamination meters

    International Nuclear Information System (INIS)

    Chen Zigen; LI Xingyuan; Shuai Xiaoping.

    1984-01-01

    It is necessary that instruments are calibrated accurately in order to obtain reliable survey data of surface contamination. Some problems in calibrating surface contamination meters are expounded in this paper. Measurement comparison for beta surface contamination meters is organized within limited scope, thus survey quality is understood, questions are discovered, significance of calibration is expounded further. (Author)

  1. BCM6: New Generation of Boron Meter

    International Nuclear Information System (INIS)

    Pirat, P.

    2010-01-01

    Full text of publication follows: Rolls-Royce has developed a new generation of boron meter, based on more than 30 years of experience. The Rolls-Royce BCM6 boron meter provides Nuclear Power Plant (NPP) operators with the boron concentration of the primary circuit. The meter provides continuous and safe measurements with no manual sampling and no human contact. In this paper, technical features, advantages and customer benefits of the use of the new generation of Rolls-Royce BCM6 boron meter will be detailed. Values and associated alarms are provides over different media: 4-20 mA outputs, relays, displays in the main control room and in the chemical lab, and digital links. A special alarm avoids unexpected homogeneous dilution of the primary circuit, which is a critical operational parameter. The Rolls-Royce BCM6 boron meter is fully configurable over a set of parameters allowing adaptation to customer needs. It has a differential capability, thus eliminating neutronic noise and keeping measurements accurate, even in the case of fuel clad rupture. Measurements are accurate, reliable, and have a quick response time. Equipment meets state-of-the-art qualification requests. Designed in 2008, the BCM6 boron meter is the newest equipment of Rolls-Royce boron meters product line. It has been chosen to equip the French EPR NPP and complies with the state-of-the-art of the technology. Rolls-Royce has more than 30 years of experience in Instrumentation and Controls with more than 75 NPP units operating worldwide. All of this experience return has been put in this new generation of equipment to provide the customer with the best operation. About Rolls-Royce Rolls-Royce is a global business providing integrated power systems for use on land, at sea and in the air. The Group has a balanced business portfolio with leading market positions. Rolls-Royce has a broad range of civil nuclear expertise, including work related to licensing and safety reviews, engineering design

  2. Carbon activity meter

    International Nuclear Information System (INIS)

    Roy, P.; Krankota, J.L.

    1975-01-01

    A carbon activity meter utilizing an electrochemical carbon cell with gaseous reference electrodes having particular application for measuring carbon activity in liquid sodium for the LMFBR project is described. The electrolyte container is electroplated with a thin gold film on the inside surface thereof, and a reference electrode consisting of CO/CO 2 gas is used. (U.S.)

  3. Interest in smart metering project surprises utility, IBM

    International Nuclear Information System (INIS)

    Horne, D.

    2006-01-01

    This article provided an outline of Hydro Ottawa and IBM's smart metering pilot project, which has resulted in high approval ratings from the public. The project features 375 participants broken down into 3 separate groups to look for potential consumption differences between customers charged according to standard time-of-use pricing; time-of-use with critical peak pricing; and time-of-use with critical peak rebates. The Ontario Smart Price Pilot project will be run for 5 months, and is expected to provide detailed energy information about usage. Past projects have indicated that customers respond quickly to smart metering, as they are able to monitor their energy usage and more effectively manage their energy consumption. Ontario plans to have all homes and small businesses using smart meters by 2010, as high seasonal demand has indicated that conservation and balanced resource use are now top priorities for many utility companies. At least 10 states in the United States have conducted smart metering pilot projects. The California Public Utilities Commissions has recently approved a $1.7 billion statewide plan to replace old meters with smart meters. In Ontario, customers have ordered 10,000 electricity monitors that Hydro One is giving away. It was concluded that research results from an earlier Hydro One demonstration project with 500 Ontario homeowners showed that real time electricity monitors can help homeowners reduce their consumption of electricity by up to 15 per cent. 4 figs

  4. Status of neutron monitoring meters for radiation protection purpose

    International Nuclear Information System (INIS)

    Li Taosheng

    2003-01-01

    The status of and trends towards the development of neutron monitoring meters, such as dose survey meter, workplace (ambient) spectrometer and individual dosimeters, are discussed in the present paper from the perspectives of workplace and individual dose monitoring. Over the past 4 decades, both neutron dose survey meter and workplace spectrometer have declined to be more reasonable in design of their probes, with more broaden applications. With the development of electronic technology, there is a trend towards being more small-compacted and smart. Although many technical difficulties in the practical measurement, some significant progresses have be made in the development and research of these kinds of meters. (authors)

  5. Downhole multiphase metering in wells by means of soft-sensing

    NARCIS (Netherlands)

    Leskens, M.; Kruif, B. de; Belfroid, S.P.C.; Smeulers, J.P.M.; Gryzlov, A.

    2008-01-01

    Multiphase flow meters are indispensable tools for achieving optimal operation and control of wells as these meters deliver real-time information about their performance. For example, multiphase flow meters located downhole can improve the production of multilateral and multizone wells by timely

  6. Hybrid TLC-pair meter for the Sphinx Project

    Science.gov (United States)

    Wada, T.; Yamamoto, I.; Takahashi, N.; Misaki, A.

    1985-01-01

    The chief aims in THE SPHINX PROJECT are research of super lepton physics and new detector experiments. At the second phase of THE SPHINX PROJECT, a hybrid TLC-PAIR METER was designed for measuring high energy neutrino sources (E upsilon * TeV), searching high energy muon sources (E mu TeV) and measuring muon group (E mu 1 TeV). The principle of PAIR METER has been already proposed. In this TLC-PAIR METER, electromagnetic shower induced by cosmic ray muons are detected using TL (Thermoluminescence) sheets with position counters.

  7. Hybrid TLC-pair meter for the Sphinx Project

    International Nuclear Information System (INIS)

    Wada, T.; Yamamoto, I.; Takahashi, N.; Misaki, A.

    1985-01-01

    The chief aims in the Sphinx Project are research on super lepton physics and new detector experiments. In the second phase of the Sphinx Project, a hybrid TLC-pair meter was designed for measuring for high energy neutrino sources (E upsilon * TeV), searching high energy muon sources (E mu TeV), and measuring muon groups (E mu 1 TeV). The principle of the pair meter has been already proposed. In this TLC pair meter, electromagnetic showers induced by cosmic ray muons are detected using thermoluminescene sheets with position counters

  8. Federal metering data analysis needs and existing tools

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, Jordan W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fowler, Kimberly M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-07-01

    Agencies have been working to improve their metering data collection, management, and analysis efforts over the last decade (since EPAct 2005) and will continue to address these challenges as new requirements and data needs come into place. Unfortunately there is no “one-size-fits-all” solution. As agencies continue to expand their capabilities to use metered consumption data to reducing resource use and improve operations, the hope is that shared knowledge will empower others to follow suit. This paper discusses the Federal metering data analysis needs and some existing tools.

  9. Deducing Energy Consumer Behavior from Smart Meter Data

    DEFF Research Database (Denmark)

    Ebeid, Emad Samuel Malki; Heick, Rune; Jacobsen, Rune Hylsberg

    2017-01-01

    The ongoing upgrade of electricity meters to smart ones has opened a new market of intelligent services to analyze the recorded meter data. This paper introduces an open architecture and a unified framework for deducing user behavior from its smart main electricity meter data and presenting...... the results in a natural language. The framework allows a fast exploration and integration of a variety of machine learning algorithms combined with data recovery mechanisms for improving the recognition’s accuracy. Consequently, the framework generates natural language reports of the user’s behavior from...

  10. Design and Study of a Low-Cost Laboratory Model Digital Wind Power Meter

    Science.gov (United States)

    Radhakrishnan, Rugmini; Karthika, S.

    2010-01-01

    A vane-type low-cost laboratory model anemometer cum power meter is designed and constructed for measuring low wind energy created from accelerating fluids. The constructed anemometer is a device which records the electrical power obtained by the conversion of wind power using a wind sensor coupled to a DC motor. It is designed for its…

  11. Delineation of marsh types and marsh-type change in coastal Louisiana for 2007 and 2013

    Science.gov (United States)

    Hartley, Stephen B.; Couvillion, Brady R.; Enwright, Nicholas M.

    2017-05-30

    The Bureau of Ocean Energy Management researchers often require detailed information regarding emergent marsh vegetation types (such as fresh, intermediate, brackish, and saline) for modeling habitat capacities and mitigation. In response, the U.S. Geological Survey in cooperation with the Bureau of Ocean Energy Management produced a detailed change classification of emergent marsh vegetation types in coastal Louisiana from 2007 and 2013. This study incorporates two existing vegetation surveys and independent variables such as Landsat Thematic Mapper multispectral satellite imagery, high-resolution airborne imagery from 2007 and 2013, bare-earth digital elevation models based on airborne light detection and ranging, alternative contemporary land-cover classifications, and other spatially explicit variables. An image classification based on image objects was created from 2007 and 2013 National Agriculture Imagery Program color-infrared aerial photography. The final products consisted of two 10-meter raster datasets. Each image object from the 2007 and 2013 spatial datasets was assigned a vegetation classification by using a simple majority filter. In addition to those spatial datasets, we also conducted a change analysis between the datasets to produce a 10-meter change raster product. This analysis identified how much change has taken place and where change has occurred. The spatial data products show dynamic areas where marsh loss is occurring or where marsh type is changing. This information can be used to assist and advance conservation efforts for priority natural resources.

  12. API testing program - calibration of microprocessor based flowmeters for integrated metering systems

    Energy Technology Data Exchange (ETDEWEB)

    Elliot, Kenneth D. [Omni Flow Computers, Inc., Stafford, TX (United States)

    2005-07-01

    Microprocessor based flowmeter technologies for liquids, such as Coriolis mass meters, and Ultrasonic flowmeters hold great promise. These technologies offer many advantages, such as no rotating parts, self-diagnostic checks, which can help anticipate and warn of impending failures before they have a major impact on the measurement. These meters are substantially different though than other primary devices due to their heavy reliance on the accompanying secondary electronics. One method to prove that they are accurate would be proving the flowmeter, using a pipe prover or small volume prover (SVP), but these proving methods are designed to count 'real time' pulses from a turbine or PD meter between a known volume, they are not designed to count 'time delayed' 'manufactured pulses' from a microprocessor. There are limitations of the manufactured pulse train and it affects the ability of the flowmeter to be proved using current proving technology. The author of this paper, a chairman of an American Petroleum Institute working group, investigated how the 'microprocessor generated pulses' produced by these types of flowmeters, interacted with the existing measurement technologies in use today. Several microprocessor based flowmeter technologies have been tested, including; Ultrasonic, Coriolis, and Helical Turbine with pulse multiplying preamplifier. Wherever possible, flowmeters of various sizes, and from several vendors have been tested. A significant amount of data has been collected which sheds light into why these types of flowmeters are sometimes difficult to prove. This paper describes the API testing program, and the methodology behind it. It presents results and findings, and offers specific recommendations that may eventually be incorporated into API documents and/or standards in the future. (author)

  13. Two stage-type railgun accelerator

    International Nuclear Information System (INIS)

    Ogino, Mutsuo; Azuma, Kingo.

    1995-01-01

    The present invention provides a two stage-type railgun accelerator capable of spiking a flying body (ice pellet) formed by solidifying a gaseous hydrogen isotope as a fuel to a thermonuclear reactor at a higher speed into a central portion of plasmas. Namely, the two stage-type railgun accelerator accelerates the flying body spiked from a initial stage accelerator to a portion between rails by Lorentz force generated when electric current is supplied to the two rails by way of a plasma armature. In this case, two sets of solenoids are disposed for compressing the plasma armature in the longitudinal direction of the rails. The first and the second sets of solenoid coils are previously supplied with electric current. After passing of the flying body, the armature formed into plasmas by a gas laser disposed at the back of the flying body is compressed in the longitudinal direction of the rails by a magnetic force of the first and the second sets of solenoid coils to increase the plasma density. A current density is also increased simultaneously. Then, the first solenoid coil current is turned OFF to accelerate the flying body in two stages by the compressed plasma armature. (I.S.)

  14. Real time Aanderaa current meter data collection system

    Digital Repository Service at National Institute of Oceanography (India)

    AshokKumar, K.; Diwan, S.G.

    Aanderaa current meters are widely used for recording the current speed and such other 4 parameters by deploying them over extended period of time. Normally data are recorded on magnetic tape and after recovery of current meters, data are read...

  15. A digital real-time reactivity meter for PFR

    International Nuclear Information System (INIS)

    McWilliams, D.

    1975-08-01

    A digital reactivity meter has been prpduced which is believed to constitute a significant advance over others reported in the literature. The main advantage of this system is its versatility which is brought about by the high degree of interactive operator control which is provided. The reactivity and power are continuously displayed in both graphical and alpha-numeric form on a TV-type of display unit. Data output is by means of an incremental graph plotter, a typewriter, or a high speed paper tape punch. The system has been extensively tested on the Prototype Fast Reactor at Dounreay and is now the standard reactivity measuring method for reactor experiments there. (author)

  16. Smart meter users give a thumbs up

    International Nuclear Information System (INIS)

    Horne, D.

    2007-01-01

    The Ontario Energy Board conducted a pilot study with the support of Hydro Ottawa to better understand how consumers change their electricity consumption behaviour with smart meters and time-of-use (TOU) prices. The project enabled consumers to learn the most cost-effective times to use energy. Results from the Ontario Smart Price Pilot reveal that consumers like to have control over how much and when they use their electricity. Although the savings were only small for some clients involved in the study, they appreciated having their metering bills in greater detail. At the end of the pilot project, participants reduced electricity consumption by 6 per cent. Nearly 90 per cent of the participants paid lower energy bills and nearly 80 per cent indicated they would recommend TOU pricing to their friends because it motivated them to shift some of their electricity use away from peak hours. The average reduction in electricity demand among the two-thirds of participants on critical pricing plans was more than 20 per cent during high demand or critical peak hours in summer. Demand reduction on winter critical peak days was much lower for all participants. 1 fig

  17. Is Individual Metering Socially Sustainable? The Case of Multifamily Housing in France

    Directory of Open Access Journals (Sweden)

    Bernard Barraqué

    2011-06-01

    Full Text Available Before generalising water metering and billing at the apartment level for consumer equity reasons, and alleviating the burden of water bills for poor families through increasing block tariffs (IBTs, Paris Council asked for some expert advice. The pros and cons of two separate issues – IBTs efficiency and justice; and individual household metering – were mixed. Our research first summarises various studies of the redistributive effects of tariff changes, first from flat rates to metering, and then from uniform prices to IBTs. We address the particular case of multifamily housing, where it is possible to retain collective billing, while relying on sub-metering to allocate the bill. The limitations of classical econometric surveys on large samples (in terms of understanding households’ strategies with tap water support the need for supplementary detailed sociological surveys at neighbourhood or building levels, if only to check the unexpected redistributive effects of tariff changes in practice. We review the specific French situation, peculiarly in Paris, to show that individual apartment billing is more costly and tends to have regressive effects. Like other cities in France, Paris abandoned the implementation of Art. 93 of the 2000 law, which encouraged individual billing; and we explain why.

  18. ORNL Pocket Meter Program: internal operating procedures

    International Nuclear Information System (INIS)

    Berger, C.D.; Miller, J.H.; Dunsmore, M.R.

    1984-12-01

    The ORNL Pocket Meter Program is designed for auditing the approximate photon radiation exposure of Oak Ridge National Laboratory (ORNL) radiation workers. Although pocket meters are considered to be a secondary personnel dosimetry system at ORNL, they are valuable indicators of unplanned exposures if proper procedures are followed for testing, calibrating, deploying, wearing, processing, and recording data. 4 figures, 1 table

  19. Implementation plan for smart meters in Ontario

    International Nuclear Information System (INIS)

    2004-01-01

    This paper presents Ontario Energy Board's implementation plan to install 800,000 smart meters by December 31, 2007. The objective is to help consumers control their electricity bills through conservation and demand response. The three conditions that will change power consumption habits are price changes in response to demand and supply forces; the ability of consumers to see and respond to the price signals; and, a measurement of the response so that consumers get credit for their actions. This paper identifies the mandatory technical requirements for smart meters and the support operations of distributors. It sets priorities, identifies barriers and regulatory mechanisms for cost recovery. It also discusses options for ownership of the meters. 18 refs., 1 tab., 2 figs

  20. Optical position meters analyzed in the noninertial reference frames

    International Nuclear Information System (INIS)

    Tarabrin, Sergey P.; Seleznyov, Alexander A.

    2008-01-01

    In the framework of general relativity we develop a method for the analysis of the operation of the optical position meters in their photodetectors proper reference frames. These frames are noninertial in general due to the action of external fluctuative forces on meters test masses, including detectors. For comparison we also perform the calculations in the laboratory (globally inertial) reference frame and demonstrate that for certain optical schemes laboratory-based analysis results in unmeasurable quantities, in contrast to the detector-based analysis. We also calculate the response of the simplest optical meters to weak plane gravitational waves and fluctuative motions of their test masses. It is demonstrated that for the round-trip meter analysis in both the transverse-traceless (TT) and local Lorentz (LL) gauges produces equal results, while for the forward-trip meter corresponding results differ in accordance with different physical assumptions (e.g. procedure of clocks synchronization) implicitly underlying the construction of the TT and LL gauges.

  1. Effects of Net Metering on the Use of Small-Scale Wind Systems in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, T. L.; Pedden, M.; Gagliano, T.

    2002-11-01

    Factors such as technological advancements, steadily decreasing costs, consumer demand, and state and federal policies are combining to make wind energy the world's fastest growing energy source. State and federal policies are facilitating the growth of the domestic, large-scale wind power market; however, small-scale wind projects (those with a capacity of less than 100 kilowatts[kW]) still face challenges in many states. Net metering, also referred to as net billing, is one particular policy that states are implementing to encourage the use of small renewable energy systems. Net metering allows individual, grid-tied customers who generate electricity using a small renewable energy system to receive credit from their utility for any excess power they generate beyond what they consume. Under most state rules, residential, commercial, and industrial customers are eligible for net metering; however, some states restrict eligibility to particular customer classes. This paper illustrates how net metering programs in certain states vary considerably in terms of how customers are credited for excess power they generate; the type and size of eligible technologies and whether the utility; the state, or some other entity administers the program. This paper focuses on10 particular states where net metering policies are in place. It analyzes how the different versions of these programs affect the use of small-scale wind technologies and whether some versions are more favorable to this technology than others. The choice of citizens in some states to net meter with photovoltaics is also examined.

  2. Smart metering gateway works as Smart Home Energy Manager; Smart Metering Gateway als Smart Home Energy Manager

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Klaus-Dieter [SSV Software Systems GmbH, Hannover (Germany)

    2011-07-01

    The installation of smart meters together with real time consumption data visualization doesn't help to save energy CO2 emissions. With regards to refinancing options, the situation in Germany has been quite different since the middle of last year for buildings equipped with a photovoltaic system. If a heat pump system is also present, intelligent energy use in conjunction with smart meters can save considerable amounts of money. A Smart Home Energy Manager (SHEM) automates the energy saving. (orig.)

  3. Attacks and their Defenses for Advanced Metering Infrastructure

    DEFF Research Database (Denmark)

    Lighari, Sheeraz Niaz; Hussain, Dil Muhammad Akbar; Bak-Jensen, Birgitte

    2014-01-01

    The smart grid is the digitized, modernized, updated version of archaic traditional electric grid. Advanced Metering Infrastructure (AMI) is an imperative part of the smart grid. It has replaced legacy metering, as it reports the energy consumption to the utility automatically through communicati...

  4. Electric Power Substitute Meter Management via Mobile Application

    Directory of Open Access Journals (Sweden)

    Nelson C. Rodelas

    2014-10-01

    Full Text Available EPSMvMA is composed of Digital Sub-Meter connected to different components namely the GSM module, Bluetooth module, Power Analyzer Module, LCD Module, Relay Module and Main Microcontroller module. The connection via Mobile is made possible by the modules mentioned. The software that the proponents will be dealing with in the study is C++ language, which will be used in programming the Main Microcontroller module and Visual Basic Language for the Android Phones. The Bluetooth module can access the Android Phones and connect to the digital sub-meter in a limited distance. The users will be at ease since a code embedded to the microcontroller will make the utility sub-meter produce the desired value of electricity (KWH and wherein the computed Sub-meter reading can be viewed through the LCD. This project is accommodating to those person that is always on the go and prudent.

  5. A Dedicated Mixture Model for Clustering Smart Meter Data: Identification and Analysis of Electricity Consumption Behaviors

    Directory of Open Access Journals (Sweden)

    Fateh Nassim Melzi

    2017-09-01

    Full Text Available The large amount of data collected by smart meters is a valuable resource that can be used to better understand consumer behavior and optimize electricity consumption in cities. This paper presents an unsupervised classification approach for extracting typical consumption patterns from data generated by smart electric meters. The proposed approach is based on a constrained Gaussian mixture model whose parameters vary according to the day type (weekday, Saturday or Sunday. The proposed methodology is applied to a real dataset of Irish households collected by smart meters over one year. For each cluster, the model provides three consumption profiles that depend on the day type. In the first instance, the model is applied on the electricity consumption of users during one month to extract groups of consumers who exhibit similar consumption behaviors. The clustering results are then crossed with contextual variables available for the households to show the close links between electricity consumption and household socio-economic characteristics. At the second instance, the evolution of the consumer behavior from one month to another is assessed through variations of cluster sizes over time. The results show that the consumer behavior evolves over time depending on the contextual variables such as temperature fluctuations and calendar events.

  6. Importance of manually entering blood glucose readings when wireless-compatible meters are not being used with an insulin pump.

    Science.gov (United States)

    Driscoll, Kimberly A; Johnson, Suzanne Bennett; Wang, Yuxia; Tang, Yuanyuan; Gill, Elizabeth C; Mitchell, Adela; Wright, Nancy; Deeb, Larry C

    2013-07-01

    The objective was to determine if there were differences in blood glucose monitoring (BGM) data downloaded from insulin pumps of patients who use meters that wirelessly transmit data to their insulin pumps (i.e., wireless group) and those who do not (i.e., nonwireless group). Blood glucose monitoring data were downloaded from the meters and insulin pumps of 47 children and adolescents with type 1 diabetes mellitus. Independent and paired t tests compared BGM data downloaded from meters and BGM data downloaded from insulin pumps. There were significant differences in BGM data downloaded from the insulin pumps of patients using wireless meters compared to those using nonwireless meters. Wireless patients appeared to engage in more BGM, had more low and in-range BG readings and fewer very high BG readingss than nonwireless patients. However, a comparison of BGM data downloaded from meters and insulin pumps of nonwireless patients indicated that their insulin pump data significantly underestimated the number of BGM readings conducted, as well as the number of low and in-range readings, while overestimating the number of very high BGM readings. Because patients who use nonwireless-compatible meters do not manually enter their low and in-range BGM readings into the insulin pump, BGM data downloaded only from pumps may provide an incomplete representation of BGM frequency or results. It is recommended that patients use meters that directly communicate with pumps or perform bolus calculations. Patients should be educated about the importance of manually entering all BGM readings if they do not use a wireless-compatible meter with their insulin pump. © 2013 Diabetes Technology Society.

  7. Liquid metal Flow Meter - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, C.; Hoogendoom, S.; Hudson, B.; Prince, J.; Teichert, K.; Wood, J.; Chase, K.

    2007-01-30

    Measuring the flow of liquid metal presents serious challenges. Current commercially-available flow meters use ultrasonic, electromagnetic, and other technologies to measure flow, but are inadequate for liquid metal flow measurement because of the high temperatures required by most liquid metals. As a result of the reactivity and high temperatures of most liquid metals, corrosion and leakage become very serious safety concerns. The purpose of this project is to develop a flow meter for Lockheed Martin that measures the flow rate of molten metal in a conduit.

  8. Chlorophyll meter for estimating nitrogen status of irrigated wheat

    International Nuclear Information System (INIS)

    Schepers, J.S.

    2000-01-01

    Chlorophyll-meter readings, generated from the leaves of irrigated wheat at particular growth stages, were normalized to the data obtained with locally recommended rates of fertilizer N, in Chile China, India and Mexico. Normalizing permitted comparisons of crop-N status across growth stages, locations, cultivars, and years. Relative yields and meter readings at growth-stage Z-50 are presented; they revealed similar trends for India, China, and Chile, however, for Mexico, the combination of soil, wheat cultivar, and climate resulted in much less response to N fertilization in the meter data. The implications are discussed. The SPAD meter proved to be a good tool to monitor and evaluate the N status of irrigated wheat. (author)

  9. Economic and social impacts of converting to tenant metering in multi-family housing

    International Nuclear Information System (INIS)

    Palermini, D.; Hewitt, D.

    1990-01-01

    A current trend in the multifamily housing industry is to convert heating (gas and oil) systems to tenant-metered heating systems (electric zonal heat, individual gas furnaces, secondary metering systems for boilers). Moving responsibility for heating costs directly to tenants has been shown to save energy (on the order of 15%). However, there are social and economic aspects of this type of 'energy investment' such as the impact on vacancy rates, rent levels and comfort of tenants. This paper presents the findings from a research project that surveyed the owners and tenants of 37 multifamily buildings (a total of 741 units) that had been converted from central to individual metering. In addition to the behavioral analysis, the authors gathered utility billing data which they analyzed using the Princeton Scorekeeping Method. Survey findings indicate that energy use was decreased substantially by conversion to separate heating systems. Increases in tenant-paid utility bills after conversion were not sufficient to cause hardship for most tenants, even those with modest incomes. Rent and vacancy levels remained stable after the heating system changes were made or an allocation system was installed

  10. How Should Blood Glucose Meter System Analytical Performance Be Assessed?

    Science.gov (United States)

    Simmons, David A

    2015-08-31

    Blood glucose meter system analytical performance is assessed by comparing pairs of meter system and reference instrument blood glucose measurements measured over time and across a broad array of glucose values. Consequently, no single, complete, and ideal parameter can fully describe the difference between meter system and reference results. Instead, a number of assessment tools, both graphical (eg, regression plots, modified Bland-Altman plots, and error grid analysis) and tabular (eg, International Organization for Standardization guidelines, mean absolute difference, and mean absolute relative difference) have been developed to evaluate meter system performance. The strengths and weaknesses of these methods of presenting meter system performance data, including a new method known as Radar Plots, are described here. © 2015 Diabetes Technology Society.

  11. The economics of metering systems with more than one user

    International Nuclear Information System (INIS)

    Andersen, P.

    1994-01-01

    The content of this paper is inspired by two different research areas. The first area is the theory of public utility pricing, and the second is the theory of common-pool resources. The first area is dominated by the idea of marginal-cost-pricing at least as a first-best approach. The second area focuses on goods where users are difficult to exclude and where there is subtractability (rivalness) in consumption. The degree of excludability depends on the amount of resources used to enforce exclusion. If enforcement costs are too high it might be preferable with a moderate degree of exclusion. This article focuses on the kind of goods provided form a public utility. Here, it is relatively easy to exclude consumers since they have to be connected to the system. On the other hand, it requires investments in metering systems to measure the consumption of each individual consumer. In this note three alternatives are considered and compared. The first system is one in which each consumer pays a fixed amount independent of consumption. The second system is one in which each consumer pays according to individual metering using marginal cost pricing. The third system in which several consumers (in this preliminary paper this means two) have a common metering system and in which they share the costs of consumption. This system (as the first one) tends to give an overuse of the consumed good. Therefore, an alternative pricing strategy is discussed, in which the individual consumer has the incentive to equate marginal willingness to pay to marginal costs. (au)

  12. Topology-Based Estimation of Missing Smart Meter Readings

    Directory of Open Access Journals (Sweden)

    Daisuke Kodaira

    2018-01-01

    Full Text Available Smart meters often fail to measure or transmit the data they record when measuring energy consumption, known as meter readings, owing to faulty measuring equipment or unreliable communication modules. Existing studies do not address successive and non-periodical missing meter readings. This paper proposes a method whereby missing readings observed at a node are estimated by using circuit theory principles that leverage the voltage and current data from adjacent nodes. A case study is used to demonstrate the ability of the proposed method to successfully estimate the missing readings over an entire day during which outages and unpredictable perturbations occurred.

  13. [Evaluation of a new electronic handheld meter for measurement of β-hydroxybutyric acid in dairy cows].

    Science.gov (United States)

    Mahrt, A; Burfeind, O; Voigtsberger, R; Müller, A; Heuwieser, W

    2014-01-01

    Subclinical ketosis (SCK), an important disease in lactating dairy cows, is defined as the presence of elevated concentrations of circulating ketone bodies without the development of clinical signs. Therefore, diagnostic methods are limited to the detection of the concentrations of ketone bodies in different body fluids. The objective of this study was to evaluate a recently developed electronic hand- held meter (NovaVet) for the determination of β-hydroxybutyric acid (BHB) in the blood of dairy cows. A total of 155 lactating dairy cows were included in the trial. Blood samples were taken from each cow and analyzed using the BHB meter. The obtained concentrations were compared to the results determined by a commercial laboratory. The Spearman's rank correlation coefficient was determined between the two methods. A Wilcoxon test was performed and a Bland-Altman plot was generated. Test characteristics (sensitivity, specificity, positive and negative predictive value) for established BHB cut points for the diagnosis of SCK were calculated using receiver operating characteristic (ROC) analysis. The two methods were highly correlated (rs = 0.87; p meter (median 1.0 mmol/l; IQR 0.7-1.3 mmol/l) and by the laboratory (median 0.9 mmol/l; IQR 0.7-1.1 mmol/l). Using a cut point of 1.2 mmol/l, sensitivity and specificity of the BHB meter were 97% and 82%, respectively. There was a good agreement between BHB concentrations determined using the BHB meter and the laboratory. Furthermore, the BHB meter displayed good test characteristics. The specificity of 82% results in a number of false-positive results. However, this new device can be recommended for the detection of SCK in cows under practical conditions.

  14. Experimental procedure for the determination of counting efficiency and sampling flow rate of a grab-sampling working level meter

    International Nuclear Information System (INIS)

    Grenier, M.; Bigu, J.

    1982-07-01

    The calibration procedures used for a working level meter (WLM) of the grab-sampling type are presented in detail. The WLM tested is a Pylon WL-1000C working level meter and it was calibrated for radon/thoron daughter counting efficiency (E), for sampling pump flow rate (Q) and other variables of interest. For the instrument calibrated at the Elliot Lake Laboratory, E was 0.22 +- 0.01 while Q was 4.50 +- 0.01 L/min

  15. TRL Assessment of Solar Sail Technology Development Following the 20-Meter System Ground Demonstrator Hardware Testing

    Science.gov (United States)

    Young, Roy M.; Adams, Charles L.

    2010-01-01

    The NASA In-Space Propulsion Technology (ISPT) Projects Office sponsored two separate, independent solar sail system design and development demonstration activities during 2002-2005. ATK Space Systems of Goleta, CA was the prime contractor for one development team and L' Garde, Inc. of Tustin, CA was the prime contractor for the other development team. The goal of these activities was to advance the technology readiness level (TRL) of solar sail propulsion from 3 towards 6 by the year 2006. Component and subsystem fabrication and testing were completed successfully, including the ground deployment of 10-meter and 20-meter demonstration hardware systems under vacuum conditions. The deployment and structural testing of the 20-meter solar sail systems was conducted in the 30 meter diameter Space Power Facility thermal-vacuum chamber at NASA Glenn Plum Brook in April though August, 2005. This paper will present the results of the TRL assessment following the solar sail technology development activities associated with the design, development, analysis and testing of the 20-meter system ground demonstrators.

  16. Design of a Spoon Wheel Type Seed Metering Device and Simulation of Soybean Seeds By Discrete Element Method%勺轮式排种器设计与大豆种子离散元法排种仿真

    Institute of Scientific and Technical Information of China (English)

    袁桂珍; 张涛; 刘月琴

    2017-01-01

    Seed metering device as a key component of the seeding machine, its working performance and reliability directly affect the overall quality of the seeding machine.Mechanical sowing machine has the advantages of simple structure, low cost, convenient maintenance.The wheel metering device as a mechanical metering device of a widely used seeding with regular shape and hardness seeds.In this paper,the Solidworks software is used to design a spoon wheel type seed metering device, and the discrete element method is used to simulate the seed sowing seeds of the seed metering device, and the working conditions of the seed metering device are obtained.Simulation results are obtained by the discrete element software: the whole working performance of the seed metering device was better when the wheel rotation speed was 10~13 r/min;the number of seeds in the seed room was 1800~2100.And appropriate vibration can improve the performance of the designed device.This paper provides a method for the design and optimization of the spoon wheel type seed metering device.%排种器作为播种机关键部件,其工作性能与可靠性直接影响播种机整体作业质量.机械式排种器具有结构简单、价格低廉、维修方便等优点,勺轮式排种器作为机械式排种器的一种,在硬度较大、较规则种子播种作业中得到广泛应用.为此,应用SolidWorks软件设计了一种勺轮式排种器,应用离散元软件对排种器排种大豆种子进行了计算机数值模拟,得到了排种器工作性能较好的工作参数.由离散元软件计算机数值模拟结果得到:勺轮组合转速为10~13r/min,排种器种子室内种子数量在1800~2100粒时,排种器整体工作性能较好;且适当的振动可提高本设计的排种器的工作性能.该研究为勺轮式排种器的设计与优化提供了一种方法.

  17. A comparison between a tristimulus colorimeter (Minolta ChromaMeter CR-200) and two spectrophotometers (Minolta Spectrophotometer CM-508i and CM-2002). Quantification of UV-B induced erythema in a hairless guinea pig model.

    Science.gov (United States)

    Fullerton, A; Keiding, J

    1997-11-01

    A comparison was made between a tristimulus colorimeter (Minolta ChromaMeter CR 200) and two spectrophotometers (Minolta CM-508i and CM-2002). The object was to compare skin colour data in the CIE 1976 L*a*d*colour space system obtained with the different instruments after UV-B exposure. Guinea pigs were exposed on their dorsal trunk with UV-B light for different time periods. Skin colour in the L*a*b* system was measured 6 and 24 h after exposure. Reproducible and objective measurements expressed in the CIE system were obtained with all three instruments. A strong correlation was found between the Minolta Chromameter CR200 and each of the two spectrophotometers. However, absolute values found with the Minolta ChromaMeter CR 200, especially for b*, differed from values obtained with the two spectrophotometers. The instruments were, despite minor inter-instrumental variation, suited for objective evaluation of erythema. The spectrophotometers were somewhat cumbersome to use due to their heavy weight and difficulties in positioning within the test sites; the Minolta CromaMeter CR200 (or later versions) is thus preferable for simple routine measurements. Use of the spectophotometers appears only indicated where specific information about skin pigments or photoactive substances relative to wavelength is needed.

  18. Research on data collection key technology of smart electric energy meters

    Science.gov (United States)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; Chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Mouhailiu; Renheng, Xu

    2018-02-01

    In recent years, smart electric energy meters are demand at 70 million to 90 million with the strong smart grid construction every year in China. However, there are some issues in smart electric energy meters data collection such as the interference of environment, low collection efficiency and inability to work when the power is off. In order to solve these issues above, it uses the RFID communication technology to collect the numbers and electric energy information of smart electric energy meters on the basis of the existing smart electric energy meters, and the related data collection communication experiments were made. The experimental result shows that the electric information and other data batch collection of RFID smart electric energy meters are realized in power and power off. It improves the efficiency and the overall success rate is 99.2% within 2 meters. It provides a new method for smart electric energy meters data collection.

  19. A Novel Smart Meter Controlling System with Dynamic IP Addresses

    DEFF Research Database (Denmark)

    Manembu, Pinrolinvic; Welang, Brammy; Kalua Lapu, Aditya

    2017-01-01

    Smart meters are the electronic devices for measuring energy consumption in real time. Usually, static public IP addresses are allocated to realize the point-to-point (P2P) communication and remote controlling for smart metering systems. This, however, restricts the wide deployment of smart meters......, due to the deficiency of public IP resources. This paper proposes a novel subscription-based communication architecture for the support of dynamic IP addresses and group controlling of smart meters. The paper evaluates the proposed architecture by comparing the traditional P2P architecture...

  20. A wireless mesh communication protocol for smart-metering

    NARCIS (Netherlands)

    Geelen, D.J.M.; Kempen, van G.M.P.; Hoogstraten, van F.; Liotta, A.

    2012-01-01

    Worldwide there has been increasing interest over the past few years for so-called "Smart Meters", in academia, governments and in industry. Such smart-metering systems need a way to communicate the collected data reliably and cost efficiently to the back-office for analysis. Several competing