WorldWideScience

Sample records for two-dimensional high-performance liquid

  1. Peak picking and the assessment of separation performance in two-dimensional high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Guiochon, Georges A [ORNL; Shalliker, R. Andrew [University of Western Sydney, Australia

    2010-01-01

    An algorithm was developed for 2DHPLC that automated the process of peak recognition, measuring their retention times, and then subsequently plotting the information in a two-dimensional retention plane. Following the recognition of peaks, the software then performed a series of statistical assessments of the separation performance, measuring for example, correlation between dimensions, peak capacity and the percentage of usage of the separation space. Peak recognition was achieved by interpreting the first and second derivatives of each respective one-dimensional chromatogram to determine the 1D retention times of each solute and then compiling these retention times for each respective fraction 'cut'. Due to the nature of comprehensive 2DHPLC adjacent cut fractions may contain peaks common to more than one cut fraction. The algorithm determined which components were common in adjacent cuts and subsequently calculated the peak maximum profile by interpolating the space between adjacent peaks. This algorithm was applied to the analysis of a two-dimensional separation of an apple flesh extract separated in a first dimension comprising a cyano stationary phase and an aqueous/THF mobile phase as the first dimension and a second dimension comprising C18-Hydro with an aqueous/MeOH mobile phase. A total of 187 peaks were detected.

  2. [Development of a droplet-interfaced high performance liquid chromatography-capillary electrophoresis two dimensional separation platform].

    Science.gov (United States)

    Ye, Linquan; Wu, Qingshi; Dai, Simin; Xiao, Zhiliang; Zhang, Bo

    2011-09-01

    Proteomics demands high resolution multidimensional separation techniques due to its extremely high complexity. Droplet microfluidics provides a series of unique advantages in manipulating micro and nanolitre samples, such as micro-volume operation, limited diffusion and none cross-contaminating, therefore has the potential to be an ideal interface strategy for multidimensional separation. Using the microchips of different structures, functions such as "droplet generation" and "oil depletion" can be realized. Based on these functions, samples can be transferred from continuous flow to segmented flow and then back to continuous flow. In this way, different separation modes can be combined. In this study, droplet technology was utilized as a novel interface strategy in combining high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). Using tryptic peptides mixture as a sample, this two dimensional HPLC-CE system provided high resolution separation with a peak capacity over 3000. This proof-of-principle study has demonstrated the usefulness of droplet interface technology in multidimensional separation.

  3. Detailed analysis of petroleum hydrocarbon attenuation in biopiles by high-performance liquid chromatography followed by comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Mao, Debin; Lookman, Richard; Van De Weghe, Hendrik; Van Look, Dirk; Vanermen, Guido; De Brucker, Nicole; Diels, Ludo

    2009-02-27

    Enhanced bioremediation of petroleum hydrocarbons in two biopiles was quantified by high-performance liquid chromatography (HPLC) followed by comprehensive two-dimensional gas chromatography (GCXGC). The attenuation of 34 defined hydrocarbon classes was calculated by HPLC-GCXGC analysis of representative biopile samples at start-up and after 18 weeks of biopile operation. In general, a-cyclic alkanes were most efficiently removed from the biopiles, followed by monoaromatic hydrocarbons. Cycloalkanes and polycyclic aromatic hydrocarbons (PAHs) were more resistant to degradation. A-cyclic biomarkers farnesane, trimethyl-C13, norpristane, pristane and phytane dropped to only about 10% of their initial concentrations. On the other hand, C29-C31 hopane concentrations remained almost unaltered after 18 weeks of biopile operation, confirming their resistance to biodegradation. They are thus reliable indicators to estimate attenuation potential of petroleum hydrocarbons in biopile processed soils.

  4. On-line combination of high performance liquid chromatography with comprehensive two-dimensional gas chromatography-triple quadrupole mass spectrometry: a proof of principle study.

    Science.gov (United States)

    Zoccali, Mariosimone; Tranchida, Peter Quinto; Mondello, Luigi

    2015-02-03

    The present contribution is focused on the on-line combination of high performance liquid chromatography (HPLC), cryogenically modulated comprehensive two-dimensional gas chromatography (GC × GC), and triple quadrupole mass spectrometry (QqQ MS), generating a very powerful unified separation-science tool. The instrument can be used in seven different combinations ranging from one-dimensional HPLC with a photodiode array detector to on-line LC × GC × GC/QqQ MS. The main focus of the present research is directed to the LC-GC × GC/QqQ MS configuration, with its analytical potential shown in a proof-of-principle study involving a very complex sample, namely, coal tar. Specifically, a normal-phase LC process enabled the separation of three classes of coal tar compounds: (1) nonaromatic hydrocarbons; (2) unsaturated compounds (with and without S); (3) oxygenated constituents. The HPLC fractions were transferred to the GC × GC instrument via a syringe-based interface mounted on an autosampler. Each fraction was subjected to a specific programmed temperature vaporizer GC × GC/QqQ MS untargeted or targeted analysis. For example, the coal tar S-containing compounds were pinpointed through multiple-reaction-monitoring analysis, while full-scan information was attained for the oxygenated constituents.

  5. DryLab® optimised two-dimensional high performance liquid chromatography for differentiation of ephedrine and pseudoephedrine based methamphetamine samples.

    Science.gov (United States)

    Andrighetto, Luke M; Stevenson, Paul G; Pearson, James R; Henderson, Luke C; Conlan, Xavier A

    2014-11-01

    In-silico optimised two-dimensional high performance liquid chromatographic (2D-HPLC) separations of a model methamphetamine seizure sample are described, where an excellent match between simulated and real separations was observed. Targeted separation of model compounds was completed with significantly reduced method development time. This separation was completed in the heart-cutting mode of 2D-HPLC where C18 columns were used in both dimensions taking advantage of the selectivity difference of methanol and acetonitrile as the mobile phases. This method development protocol is most significant when optimising the separation of chemically similar chemical compounds as it eliminates potentially hours of trial and error injections to identify the optimised experimental conditions. After only four screening injections the gradient profile for both 2D-HPLC dimensions could be optimised via simulations, ensuring the baseline resolution of diastereomers (ephedrine and pseudoephedrine) in 9.7 min. Depending on which diastereomer is present the potential synthetic pathway can be categorized.

  6. Two-dimensional liquid chromatography

    DEFF Research Database (Denmark)

    Græsbøll, Rune

    of this thesis is on online comprehensive two-dimensional liquid chromatography (online LC×LC) with reverse phase in both dimensions (online RP×RP). Since online RP×RP has not been attempted before within this research group, a significant part of this thesis consists of knowledge and experience gained...

  7. Qualitative and quantitative two-dimensional thin-layer chromatography/high performance liquid chromatography/diode-array/electrospray-ionization-time-of-flight mass spectrometry of cholinesterase inhibitors.

    Science.gov (United States)

    Mroczek, Tomasz

    2016-09-10

    Recently launched thin-layer chromatography-mass spectrometry (TLC-MS) interface enabling extraction of compounds directly from TLC plates into MS ion source was unusually extended into two-dimensional thin-layer chromatography/high performance liquid chromatography (2D, TLC/HPLC) system by its a direct connection to a rapid resolution 50×2.1mm, I.D. C18 column compartment followed by detection by diode array (DAD) and electrospray ionisation time-of-flight mass spectrometry (ESI-TOF-MS). In this way, even not separated bands of complicated mixtures of natural compounds could be analysed structurally, only within 1-2min after development of TLC plates. In comparison to typically applied TLC-MS interface, no ion suppression for acidic mobile phases was observed. Also, substantial increase in ESI-TOF-MS sensitivities and quality of spectra, were noticed. It has been utilised in combination with TLC- based bioautographic approaches of acetylcholinesterase (AChE) inhibitors, However, it can be also applied in any other procedures related to bioactivity (e.g. 2,2-Diphenyl-1-picryl-hydrazyl-DPPH screen test for radicals). This system has been also used for determination of half maximal inhibitory concentration (IC50 values) of the active inhibitor-galanthamine, as an example. Moreover, AChE inhibitory potencies of some of purified plant extracts, never studied before, have been quantitatively measured. This is first report of usage such the 2D TLC/HPLC/MS system both for qualitative and quantitative evaluation of cholinesterase inhibitors in biological matrices. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Establishing a protein expression profile database for the normal human pituitary gland using two-dimensional high-performance liquid chromatography combined with LTQ-Orbitrap mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Rong Xie; Wei Xu; Weimin Bao; Hang Liu; Luping Chen; Yiwen Shen; Jianhong Zhu

    2012-01-01

    In this study, we selected adult normal pituitary gland tissues from six patients during operations for pituitary microadenomas via the transsphenoidal approach for extended normal pituitary tissue resection around the tumor, and analyzed the protein expression of human normal pituitary using two-dimensional high-performance liquid chromatography combined with LTQ-Orbitrap mass spectrometry proteomics technology. The ten most highly expressed proteins in normal human pituitary were: alpha 3 type VI collagen isoform 5 precursor (abundance among tall pituitary proteins, 1.30%), fibrinogen beta chain preproprotein (0.99%), vimentin (0.73%), prolactin (0.69%), ATP synthase, H+ transporting and mitochondrial F1 complex beta subunit precursor (0.52%), keratin I (0.49%), growth hormone (0.45%), carbonic anhydrase I (0.40%), heat shock protein 90 kDa I (0.31%), and annexin V (0.30%). Based on the biological function classifications of these proteins, the top three categories by content were neuroendocrine proteins (abundance among all pituitary proteins, 40.1%), catalytic and metabolic proteins (28.3%), and cell signal transduction proteins (9.8%). Based on cell positioning classification, the top three categories were cell organelle (24.5%), membrane (20.8%), and cytoplasm (13.0%). Based on biological process classification, the top three categories of proteins are involved in physiological processes (42.9%), cellular processes (40.4%), and regulation of biological processes (9.1%). Our experimental findings indicate that a protein expression profile database of normal human pituitary can be precisely and efficiently established by proteomics technology.

  9. Two-dimensional liquid chromatography

    DEFF Research Database (Denmark)

    Græsbøll, Rune

    Two-dimensional liquid chromatography has received increasing interest due to the rise in demand for analysis of complex chemical mixtures. Separation of complex mixtures is hard to achieve as a simple consequence of the sheer number of analytes, as these samples might contain hundreds or even...... dimensions. As a consequence of the conclusions made within this thesis, the research group has, for the time being, decided against further development of online LC×LC systems, since it was not deemed ideal for the intended application, the analysis of the polar fraction of oil. Trap-and...

  10. Quality evaluation of Hypericum ascyron extract by two-dimensional high-performance liquid chromatography coupled with the colorimetric 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide method.

    Science.gov (United States)

    Li, Xiu-Mei; Luo, Xue-Gang; Zhang, Chao-Zheng; Wang, Nan; Zhang, Tong-Cun

    2015-02-01

    In this paper, a heart-cutting two-dimensional high-performance liquid chromatography coupled with the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) method was established for controlling the quality of different batches of Hypericum ascyron extract for the first time. In comparison with the common one-dimensional fingerprint, the second-dimensional fingerprint compiled additional spectral data and was hence more informative. The quality of H. ascyron extract was further evaluated by similarity measures and the same results were achieved, the correlation coefficients of the similarity of ten batches of H. ascyron extract were >0.99. Furthermore, we also evaluated the quality of the ten batches of H. ascyron extract by antibacterial activity. The result demonstrated that the quality of the ten batches of H. ascyron extract was not significantly different by MTT. Finally, we demonstrated that the second-dimensional fingerprint coupled with the MTT method was a more powerful tool to characterize the quality of samples of batch to batch. Therefore the proposed method could be used to comprehensively conduct the quality control of traditional Chinese medicines.

  11. High Performance Liquid Chromatography

    Science.gov (United States)

    Talcott, Stephen

    High performance liquid chromatography (HPLC) has many applications in food chemistry. Food components that have been analyzed with HPLC include organic acids, vitamins, amino acids, sugars, nitrosamines, certain pesticides, metabolites, fatty acids, aflatoxins, pigments, and certain food additives. Unlike gas chromatography, it is not necessary for the compound being analyzed to be volatile. It is necessary, however, for the compounds to have some solubility in the mobile phase. It is important that the solubilized samples for injection be free from all particulate matter, so centrifugation and filtration are common procedures. Also, solid-phase extraction is used commonly in sample preparation to remove interfering compounds from the sample matrix prior to HPLC analysis.

  12. Simultaneous analysis of aspartame and its hydrolysis products of Coca-Cola Zero by on-line postcolumn derivation fluorescence detection and ultraviolet detection coupled two-dimensional high-performance liquid chromatography.

    Science.gov (United States)

    Cheng, Cheanyeh; Wu, Shing-Chen

    2011-05-20

    An innovative two-dimensional high-performance liquid chromatography system was developed for the simultaneous analysis of aspartame and its hydrolysis products of Coca-Cola Zero. A C8 reversed-phase chromatographic column with ultraviolet detection was used as the first dimension for the determination of aspartame, and a ligand-exchange chromatographic column with on-line postcolumn derivation fluorescence detection was employed as the second dimension for the analysis of amino acid enantiomers. The fluorimetric derivative reagent of amino acid enantiomers was o-phthaldialdehyde. The hydrolysis of aspartame in Coca-Cola Zero was induced by electric-heating or microwave heating. Aspartame was quantified by the matrix matched external standard calibration curve with a linear concentration range of 0-50 μg mL(-1) (r(2)=0.9984). The limit of detection (LOD) and the limit of quantification (LOQ) were 1.3 μg mL(-1) and 4.3 μg mL(-1), respectively. The amino acid enantiomers was analyzed by the matrix matched internal standard calibration method (D-leucine as the internal standard) with a linear concentration range of 0-10 μg mL(-1) (r(2)=0.9988-0.9997). The LODs and LOQs for L- and D-aspartic acid and L- and D-phenylalanine were 0.16-0.17 μg mL(-1) and 0.52-0.55 μg mL(-1), respectively, that was 12-13 times more sensitive than ultraviolet detection. The overall analysis accuracy for aspartame and amino acid enantiomers was 90.2-99.2% and 90.4-96.2%, respectively. The overall analysis precision for aspartame and amino acid enantiomers was 0.1-1.7% and 0.5-6.7%, respectively. Generally, the extent of aspartame hydrolysis increases with the increase of electro-thermal temperature, microwave power, and the duration of hydrolysis time. D-aspartic acid and D-phenylalanine can be observed with the electro-thermal racemization at the hydrolysis temperature 120°C for 1 day and only D-aspartic acid can be observed at the hydrolysis temperature 90°C for 2 and 3 days. For

  13. Use of on-line stop-flow heart-cutting two-dimensional high performance liquid chromatography for simultaneous determination of 12 major constituents in tartary buckwheat (Fagopyrum tataricum Gaertn).

    Science.gov (United States)

    Ren, Qiang; Wu, Caisheng; Zhang, Jinlan

    2013-08-23

    The use of two-dimensional liquid chromatography (2D-LC) for quantification studies presents challenges with respect to repeatability, precision, and robustness. The present study used an on-line stop-flow heart-cutting 2D-LC system to determine 12 chemical constituents in tartary buckwheat. A combination of various stationary phases was developed and bridged using two switch valves as the interface. Hydrophilic interaction chromatography was chosen for separation in the first dimension ((1)D), and mixed mode stationary phases (an amide polar-embedded phase and alkyl-phenyl phase) were used in parallel for separation in the second dimension ((2)D). The mobile phase comprised acetonitrile and water containing 0.03% aqueous phosphoric acid. The sample was separated into two fractions on the (1)D column (HILIC-10 column) using 5% acetonitrile. One fraction, mainly comprising flavonoids, was directly eluted onto the head of (2)D column (Polar Advantage II column) and further separated using a linear gradient of 11-23% acetonitrile. The second fraction, containing phenylpropanoid glycosides, was trapped on the (1)D column. This retained fraction was back-flushed onto the (2)D column (Phenyl-1 column) and separated using a linear gradient of 35-43% acetonitrile. An on-line stop-flow heart-cutting 2D-LC system was successfully developed with column switching and back-flush. This 2D-LC system was validated and was able to simultaneously determine 12 major components in tartary buckwheat: seven flavonoids, four phenylpropanoid glycosides, and N-trans-feruloyltyramine. The system showed good performance with respect to linearity (r>0.996), repeatability (RSD, relative standard deviation<3.4%), intra-day and inter-day precision (RSD<4.6%), recovery (91.2-108%), limit of detection (LOD) (0.05-0.21μg/mL), and limit of quantification (LOQ) (0.10-0.41μg/mL). The on-line stop-flow heart-cutting 2D-LC system offers a potential approach to analyze compounds, which have similar

  14. Development of a two-dimensional high-performance liquid chromatography system coupled with on-line reduction as a new efficient analytical method of 3-nitrobenzanthrone, a potential human carcinogen.

    Science.gov (United States)

    Hasei, Tomohiro; Nakanishi, Haruka; Toda, Yumiko; Watanabe, Tetsushi

    2012-08-31

    3-Nitrobenzanthrone (3-NBA) is an extremely strong mutagen and carcinogen in rats inducing squamous cell carcinoma and adenocarcinoma. We developed a new sensitive analytical method, a two-dimensional HPLC system coupled with on-line reduction, to quantify non-fluorescent 3-NBA as fluorescent 3-aminobenzanthrone (3-ABA). The two-dimensional HPLC system consisted of reversed-phase HPLC and normal-phase HPLC, which were connected with a switch valve. 3-NBA was purified by reversed-phase HPLC and reduced to 3-ABA with a catalyst column, packed with alumina coated with platinum, in ethanol. An alcoholic solvent is necessary for reduction of 3-NBA, but 3-ABA is not fluorescent in the alcoholic solvent. Therefore, 3-ABA was separated from alcohol and impurities by normal-phase HPLC and detected with a fluorescence detector. Extracts from surface soil, airborne particles, classified airborne particles, and incinerator dust were applied to the two-dimensional HPLC system after clean-up with a silica gel column. 3-NBA, detected as 3-ABA, in the extracts was found as a single peak on the chromatograms without any interfering peaks. 3-NBA was detected in 4 incinerator dust samples (n=5). When classified airborne particles, that is, those 7.0 μm in size, were applied to the two-dimensional HPLC system after purified using a silica gel column, 3-NBA was detected in those particles with particle sizes NBA in airborne particles and the detection of 3-NBA in incinerator dust. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Functionalized graphene for high-performance two-dimensional spintronics devices.

    Science.gov (United States)

    Li, Linze; Qin, Rui; Li, Hong; Yu, Lili; Liu, Qihang; Luo, Guangfu; Gao, Zhengxiang; Lu, Jing

    2011-04-26

    Using first-principles calculations, we explore the possibility of functionalized graphene as a high-performance two-dimensional spintronics device. Graphene functionalized with O on one side and H on the other side in the chair conformation is found to be a ferromagnetic metal with a spin-filter efficiency up to 54% at finite bias. The ground state of graphene semifunctionalized with F in the chair conformation is an antiferromagnetic semiconductor, and we construct a spin-valve device from it by introducing a magnetic field to stabilize its metallic ferromagnetic state. The resulting room-temperature magnetoresistance is up to 2200%, which is 1 order of magnitude larger than the available experimental values.

  16. A two-dimensional spin liquid in quantum kagome ice.

    Science.gov (United States)

    Carrasquilla, Juan; Hao, Zhihao; Melko, Roger G

    2015-06-22

    Actively sought since the turn of the century, two-dimensional quantum spin liquids (QSLs) are exotic phases of matter where magnetic moments remain disordered even at zero temperature. Despite ongoing searches, QSLs remain elusive, due to a lack of concrete knowledge of the microscopic mechanisms that inhibit magnetic order in materials. Here we study a model for a broad class of frustrated magnetic rare-earth pyrochlore materials called quantum spin ices. When subject to an external magnetic field along the [111] crystallographic direction, the resulting interactions contain a mix of geometric frustration and quantum fluctuations in decoupled two-dimensional kagome planes. Using quantum Monte Carlo simulations, we identify a set of interactions sufficient to promote a groundstate with no magnetic long-range order, and a gap to excitations, consistent with a Z2 spin liquid phase. This suggests an experimental procedure to search for two-dimensional QSLs within a class of pyrochlore quantum spin ice materials.

  17. DISCRETE MODELLING OF TWO-DIMENSIONAL LIQUID FOAMS

    Institute of Scientific and Technical Information of China (English)

    Qicheng Sun

    2003-01-01

    Liquid foam is a dense random packing of gas or liquid bubbles in a small amount of immiscible liquid containing surfactants. The liquid within the Plateau borders, although small in volume, causes considerable difficulties to the investigation of the spatial structure and physical properties of foams, and the situation becomes even more complicated as the fluid flows. To solve these problems, a discrete model of two-dimensional liquid foams on the bubble scale is proposed in this work. The bubble surface is represented with finite number of nodes, and the liquid within Plateau borders is discretized into lattice particles. The gas in bubbles is treated as ideal gas at constant temperatures. This model is tested by choosing an arbitrary shape bubble as the initial condition. This then automatically evolves into a circular shape, which indicates that the surface energy minimum routine is obeyed without calling external controlling conditions. Without inserting liquid particle among the bubble channels, periodic ordered and disordered dry foams are both simulated, and the fine foam structures are developed. Wet foams are also simulated by inserting fluid among bubble channels. The calculated coordination number, as a function of liquid fractions, agrees well with the standard values.

  18. Comprehensive two-dimensional liquid chromatographic analysis of poloxamers.

    Science.gov (United States)

    Malik, Muhammad Imran; Lee, Sanghoon; Chang, Taihyun

    2016-04-15

    Poloxamers are low molar mass triblock copolymers of poly(ethylene oxide) (PEO) and poly(propylene oxide) (PPO), having number of applications as non-ionic surfactants. Comprehensive one and two-dimensional liquid chromatographic (LC) analysis of these materials is proposed in this study. The separation of oligomers of both types (PEO and PPO) is demonstrated for several commercial poloxamers. This is accomplished at the critical conditions for one of the block while interaction for the other block. Reversed phase LC at CAP of PEO allowed for oligomeric separation of triblock copolymers with regard to PPO block whereas normal phase LC at CAP of PPO renders oligomeric separation with respect to PEO block. The oligomeric separation with regard to PEO and PPO are coupled online (comprehensive 2D-LC) to reveal two-dimensional contour plots by unconventional 2D IC×IC (interaction chromatography) coupling. The study provides chemical composition mapping of both PEO and PPO, equivalent to combined molar mass and chemical composition mapping for several commercial poloxamers.

  19. Two dimensional NMR of liquids and oriented molecules

    Energy Technology Data Exchange (ETDEWEB)

    Gochin, M.

    1987-02-01

    Chapter 1 discusses the quantum mechanical formalism used for describing the interaction between magnetic dipoles that dictates the appearance of a spectrum. The NMR characteristics of liquids and liquid crystals are stressed. Chapter 2 reviews the theory of multiple quantum and two dimensional NMR. Properties of typical spectra and phase cycling procedures are discussed. Chapter 3 describes a specific application of heteronuclear double quantum coherence to the removal of inhomogeneous broadening in liquids. Pulse sequences have been devised which cancel out any contribution from this inhomogeneity to the final spectrum. An interpretation of various pulse sequences for the case of /sup 13/C and /sup 1/H is given, together with methods of spectral editing by removal or retention of the homo- or heteronuclear J coupling. The technique is applied to a demonstration of high resolution in both frequency and spatial dimensions with a surface coil. In Chapter 4, multiple quantum filtered 2-D spectroscopy is demonstrated as an effective means of studying randomly deuterated molecules dissolved in a nematic liquid crystal. Magnitudes of dipole coupling constants have been determined for benzene and hexane, and their signs and assignments found from high order multiple quantum spectra. For the first time, a realistic impression of the conformation of hexane can be estimated from these results. Chapter 5 is a technical description of the MDB DCHIB-DR11W parallel interface which has been set up to transfer data between the Data General Nova 820 minicomputer, interfaced to the 360 MHz spectrometer, and the Vax 11/730. It covers operation of the boards, physical specifications and installation, and programs for testing and running the interface.

  20. Two-Dimensional Atomic-Layered Alloy Junctions for High-Performance Wearable Chemical Sensor.

    Science.gov (United States)

    Cho, Byungjin; Kim, Ah Ra; Kim, Dong Jae; Chung, Hee-Suk; Choi, Sun Young; Kwon, Jung-Dae; Park, Sang Won; Kim, Yonghun; Lee, Byoung Hun; Lee, Kyu Hwan; Kim, Dong-Ho; Nam, Jaewook; Hahm, Myung Gwan

    2016-08-03

    We first report that two-dimensional (2D) metal (NbSe2)-semiconductor (WSe2)-based flexible, wearable, and launderable gas sensors can be prepared through simple one-step chemical vapor deposition of prepatterned WO3 and Nb2O5. Compared to a control device with a Au/WSe2 junction, gas-sensing performance of the 2D NbSe2/WSe2 device was significantly enhanced, which might have resulted from the formation of a NbxW1-xSe2 transition alloy junction lowering the Schottky barrier height. This would make it easier to collect charges of channels induced by molecule adsorption, improving gas response characteristics toward chemical species including NO2 and NH3. 2D NbSe2/WSe2 devices on a flexible substrate provide gas-sensing properties with excellent durability under harsh bending. Furthermore, the device stitched on a T-shirt still performed well even after conventional cleaning with a laundry machine, enabling wearable and launderable chemical sensors. These results could pave a road toward futuristic gas-sensing platforms based on only 2D materials.

  1. Two-dimensional materials for novel liquid separation membranes

    Science.gov (United States)

    Ying, Yulong; Yang, Yefeng; Ying, Wen; Peng, Xinsheng

    2016-08-01

    Demand for a perfect molecular-level separation membrane with ultrafast permeation and a robust mechanical property for any kind of species to be blocked in water purification and desalination is urgent. In recent years, due to their intrinsic characteristics, such as a unique mono-atom thick structure, outstanding mechanical strength and excellent flexibility, as well as facile and large-scale production, graphene and its large family of two-dimensional (2D) materials are regarded as ideal membrane materials for ultrafast molecular separation. A perfect separation membrane should be as thin as possible to maximize its flux, mechanically robust and without failure even if under high loading pressure, and have a narrow nanochannel size distribution to guarantee its selectivity. The latest breakthrough in 2D material-based membranes will be reviewed both in theories and experiments, including their current state-of-the-art fabrication, structure design, simulation and applications. Special attention will be focused on the designs and strategies employed to control microstructures to enhance permeation and selectivity for liquid separation. In addition, critical views on the separation mechanism within two-dimensional material-based membranes will be provided based on a discussion of the effects of intrinsic defects during growth, predefined nanopores and nanochannels during subsequent fabrication processes, the interlayer spacing of stacking 2D material flakes and the surface charge or functional groups. Furthermore, we will summarize the significant progress of these 2D material-based membranes for liquid separation in nanofiltration/ultrafiltration and pervaporation. Lastly, we will recall issues requiring attention, and discuss existing questionable conclusions in some articles and emerging challenges. This review will serve as a valuable platform to provide a compact source of relevant and timely information about the development of 2D material-based membranes as

  2. On the critical behaviour of two-dimensional liquid crystals

    Directory of Open Access Journals (Sweden)

    A.l. Fariñas-Sánchez

    2010-01-01

    Full Text Available The Lebwohl-Lasher (LL model is the traditional model used to describe the nematic-isotropic transition of real liquid crystals. In this paper, we develop a numerical study of the temperature behaviour and of finite-size scaling of the two-dimensional (2D LL-model. We discuss two possible scenarios. In the first one, the 2D LL-model presents a phase transition similar to the topological transition appearing in the 2D XY-model. In the second one, the 2D LL-model does not exhibit any critical transition, but its low temperature behaviour is rather characterized by a crossover from a disordered phase to an ordered phase at zero temperature. We realize and discuss various comparisons with the 2D XY-model and the 2D Heisenberg model. Having added finite-size scaling behaviour of the order parameter and conformal mapping of order parameter profile to previous studies, we analyze the critical scaling of the probability distribution function, hyperscaling relations and stiffness order parameter and conclude that the second scenario (no critical transition is the most plausible.

  3. Two-dimensional high-performance thin-layer chromatography of tryptic bovine albumin digest using normal- and reverse-phase systems with silanized silica stationary phase.

    Science.gov (United States)

    Gwarda, Radosław Łukasz; Dzido, Tadeusz Henryk

    2013-10-18

    Among many advantages of planar techniques, two-dimensional (2D) separation seems to be the most important for analysis of complex samples. Here we present quick, simple and efficient two-dimensional high-performance thin-layer chromatography (2D HPTLC) of bovine albumin digest using commercial HPTLC RP-18W plates (silica based stationary phase with chemically bonded octadecyl ligands of coverage density 0.5μmol/m(2) from Merck, Darmstadt). We show, that at low or high concentration of water in the mobile phase comprised methanol and some additives the chromatographic systems with the plates mentioned demonstrate normal- or reversed-phase liquid chromatography properties, respectively, for separation of peptides obtained. These two systems show quite different separation selectivity and their combination into 2D HPTLC process provides excellent separation of peptides of the bovine albumin digest. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Theories to support method development in comprehensive two-dimensional liquid chromatography - A review

    NARCIS (Netherlands)

    Bedani, F.; Schoenmakers, P.J.; Janssen, H.-G.

    2012-01-01

    On-line comprehensive two-dimensional liquid chromatography techniques promise to resolve samples that current one-dimensional liquid chromatography methods cannot adequately deal with. To make full use of the potential of two-dimensional liquid chromatography, optimization is required. Optimization

  5. High-performance liquid chromatography of biopolymers

    Energy Technology Data Exchange (ETDEWEB)

    Regnier, F.E.

    1983-10-21

    The ability to separate biological macromolecules with good resolution on liquid chromatographic columns has depended on the development of suitable packing materials. In size exclusion chromatography, molecules are separated by size on the basis of differential permeation of the packing. Ion exchange, hydrophobic interaction (or reversed-phase), and affinity chromatography are all surface-mediated separation methods, although they depend on different retention mechanisms. High-performance liquid chromatographic columns designed for biopolymers offer major advantages over conventional columns in both speed and resolving power. The exponential growth of literature on the high-performance separation of peptides and proteins in particular indicates that the techniques will become the dominant form of column liquid chromatography. 92 refs., 4 figs.

  6. Two-dimensional liquid separations-mass mapping of proteins from human cancer cell lysates.

    Science.gov (United States)

    Lubman, David M; Kachman, Maureen T; Wang, Haixing; Gong, Siyuan; Yan, Fang; Hamler, Rick L; O'Neil, Kimberly A; Zhu, Kan; Buchanan, Nathan S; Barder, Timothy J

    2002-12-25

    A review of two-dimensional (2D) liquid separation methods used in our laboratory to map the protein content of human cancer cells is presented herein. The methods discussed include various means of fractionating proteins according to isoelectric point (pI) in the first dimension. The proteins in each pI fraction are subsequently separated using nonporous (NPS) reversed-phase high-performance liquid chromatography (RP-HPLC). The liquid eluent of the RP-HPLC separation is directed on-line into an electrospray ionization time-of-flight (ESI-TOF) mass spectrometer where an accurate value of the protein intact M(r) can be obtained. The result is a 2D map of pI versus M(r) analogous to 2D gel electrophoresis; however the highly accurate and reproducible M(r) serves as the basis for interlysate comparisons. In addition, the use of liquid separations allows for the collection of hundreds of purified proteins in the liquid phase for further analysis via peptide mass mapping using matrix assisted laser desorption ionization TOF MS. A description of the methodology used and its applications to analysis of several types of human cancer cell lines is described. The potential of the method for differential proteomic analysis for the identification of biomarkers of disease is discussed.

  7. Basic prinicipal of high performance liquid chromatography

    OpenAIRE

    Ivanova, Violeta

    2016-01-01

    High-performance liquid chromatography (HPLC) is an analytical technique based on the separation of molecules due to differences in their structure and/or composition. Separation is performed between two phases, mobile and stationary. The molecules in the sample have different affinities and interactions with the stationary support, leading to separation of molecules. Compounds which are longer retained at the stationary phase will elute later, compared to those which are distributed into the...

  8. On Regularity Criteria for the Two-Dimensional Generalized Liquid Crystal Model

    Directory of Open Access Journals (Sweden)

    Yanan Wang

    2014-01-01

    Full Text Available We establish the regularity criteria for the two-dimensional generalized liquid crystal model. It turns out that the global existence results satisfy our regularity criteria naturally.

  9. Exfoliation of two-dimensional zeolites in liquid polybutadienes

    KAUST Repository

    Sabnis, Sanket

    2017-06-16

    Layered zeolite precursors were successfully exfoliated by brief shearing or sonication with the assistance of commercially available telechelic liquid polybutadienes at room temperature. The exfoliated zeolite nanosheets can form a stable suspension in an organic solvent, providing exciting potential for the fabrication of zeolite membranes, composite materials and hierarchical zeolites.

  10. Two-dimensional low-resistance contacts for high performance WSe2 and MoS2 transistors

    Science.gov (United States)

    Chuang, Hsun-Jen

    Two-dimensional layered materials beyond graphene such as transition metal dichalcogenides (TMDs) have attracted a lot of interests due to their superior property in many aspects. In this work, I am focusing on two TMD materials: WSe2 and MoS2. The main objective this work is to develop novel approaches to fabricating low-resistance ohmic contacts to TMDs for low power, high performance electronic applications. First, we used graphene as electrical contacts for WSe2 field-effect transistor with superior performance, including a high ON/OFF ratio of >107 at 170 K, large electron mobility of 330 cm2V-1s -1 and he hole mobility of 270 cm2V-1s -1 at 77 K, and low contact resistance of 2kΩ microm. Second, we developed a novel 2D to 2D contacts strategy2 for a variety of TMDs by van der Waals assembly of substitutionally doped TMDs as drain/source contacts and TMDs with no intentional doping as channel materials. The high intrinsic behavior of the device is revealed, where it exhibits low contact resistances of 0.3 kΩ microm, on/off ratios up to > 109 as well as two-terminal field-effect hole mobility muFE ≈ 2x102 cm2 V-1 s -1 at 300K, which increases to > 6x103 cm 2 V-1 s-1 down to 10K. The 2D/2D low-resistance ohmic contacts presented here represent a new device paradigm that overcomes a significant bottleneck in the performance of TMDs and other 2D materials as the channel materials in post-silicon electronic.

  11. Two-dimensional liquid chromatography and its application in traditional Chinese medicine analysis and metabonomic investigation.

    Science.gov (United States)

    Li, Zheng; Chen, Kai; Guo, Meng-zhe; Tang, Dao-quan

    2016-01-01

    Two-dimensional liquid chromatography has become an attractive analytical tool for the separation of complex samples due to its enhanced selectivity, peak capacity, and resolution compared with one-dimensional liquid chromatography. Recently, more attention has been drawn on the application of this separation technique in studies concerning traditional Chinese medicines, metabonomes, proteomes, and other complex mixtures. In this review, we aim to examine the application of two-dimensional liquid chromatography in traditional Chinese medicine analysis and metabonomic investigation. The classification and evaluation indexes were first introduced. Then, various switching methods were summarized when used in an on-line two-dimensional liquid chromatography system. Finally, the applications of this separation technique in traditional Chinese medicine analysis and metabonomic investigation were discussed on the basis of specific studies.

  12. Characterization of hydroxypropylmethylcellulose (HPMC) using comprehensive two-dimensional liquid chromatography

    NARCIS (Netherlands)

    Greiderer, A.; Steeneken, L.; Aalbers, T.; Vivó-Truyols, G.; Schoenmakers, P.

    2011-01-01

    Various hydroxyl-propylmethylcellulose (HPMC) polymers were characterized according to size and compositional distributions (percentage of methoxyl and hydroxyl-propoxyl substitution) by means of comprehensive two-dimensional liquid chromatography (LC × LC) using reversed-phase (RP) liquid chromatog

  13. High Performance Liquid Chromatography/Video Fluorometry. Part I. Instrumentation.

    Science.gov (United States)

    1981-09-30

    High Performance Liquid Chromatography /Video...PERIOD COVERED High Performance Liquid Chromatography /Video .. / Fluorometry. Part I. Instrumentation. . Interim/ echnicaliepart,. 6. PERFORMING ORG...34Entered SECURITY CLASSIFICATION OF THIS OlAGE (When Data Entered) II1| III I I I I E I II ... .. High Performance Liquid Chromatography

  14. Enantioselective reaction monitoring utilizing two-dimensional heart-cut liquid chromatography on an integrated microfluidic chip.

    Science.gov (United States)

    Lotter, Carsten; Poehler, Elisabeth; Heiland, Josef J; Mauritz, Laura; Belder, Detlev

    2016-11-29

    Chip-integrated, two-dimensional high performance liquid chromatography is introduced to monitor enantioselective continuous micro-flow synthesis. The herein described development of the first two-dimensional HPLC-chip was realized by the integration of two different columns packed with reversed-phase and chiral stationary phase material on a microfluidic glass chip, coupled to mass spectrometry. Directed steering of the micro-flows at the joining transfer cross enabled a heart-cut operation mode to transfer the chiral compound of interest from the first to the second chromatographic dimension. This allows for an interference-free determination of the enantiomeric excess by seamless hyphenation to electrospray mass spectrometry. The application for rapid reaction optimization at micro-flow conditions is exemplarily shown for the asymmetric organocatalytic continuous micro-flow synthesis of warfarin.

  15. One- and two-dimensional fluids properties of smectic, lamellar and columnar liquid crystals

    CERN Document Server

    Jakli, Antal

    2006-01-01

    Smectic and lamellar liquid crystals are three-dimensional layered structures in which each layer behaves as a two-dimensional fluid. Because of their reduced dimensionality they have unique physical properties and challenging theoretical descriptions, and are the subject of much current research. One- and Two-Dimensional Fluids: Properties of Smectic, Lamellar and Columnar Liquid Crystals offers a comprehensive review of these phases and their applications. The book details the basic structures and properties of one- and two-dimensional fluids and the nature of phase transitions. The later chapters consider the optical, magnetic, and electrical properties of special structures, including uniformly and non-uniformly aligned anisotropic films, lyotropic lamellar systems, helical and chiral structures, and organic anisotropic materials. Topics also include typical and defective features, magnetic susceptibility, and electrical conductivity. The book concludes with a review of current and potential applications ...

  16. Verification of high performance two-dimensional particle-in-cell simulations of low-temperature plasmas

    Science.gov (United States)

    Leggate, Huw; Turner, Miles

    2016-09-01

    We discuss a two-dimensional implementation of the particle-in-cell algorithm with Monte Carlo collisions. This implementation is designed for multiprocessor environments in which each processor is assumed to offer vector capabilities and multiple execution threads. An appropriate implementation therefore combines OpenMP to exploit multithreading with MPI to coupled computing nodes. This approach promises to achieve accelerations of a least a factor of several hundred, relative to to a simple serial implementation. However, the complexity involved also offers many opportunities for error, and makes correctness demonstrations especially desirable. In this presentation we discuss the characteristics of this parallel implementation, and we describe a suite of verification tests that collectively create a strong presumption that the code is correct. Work supported by the EUROfusion consortium.

  17. High-performance photodetectors and enhanced photocatalysts of two-dimensional TiO2 nanosheets under UV light excitation

    Science.gov (United States)

    Yang, Jiao; Jiang, Yi-Lin; Li, Lin-Jie; Muhire, Elisée; Gao, Mei-Zhen

    2016-04-01

    Due to the large surface area-to-volume ratio and rapid electron transfer, two-dimensional (2D) TiO2 nanosheets with ultrathin thicknesses are synthesized by using a bottom-up strategy and these self-assembled nanosheet (NS)-based photocatalysts and photodetectors were explored for the first time. The influence of calcination temperature on microstructures and photocatalytic activity of TiO2 nanosheets were discovered and presented. The as-obtained TiO2 nanosheets were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Brunauer-Emmett-Teller (BET) analysis, Fourier transform infrared (FTIR) spectroscopy, UV-vis spectrophotometry, and X-ray photoelectron spectroscopy (XPS). The following heat treatment process induced phase evolution from rutile to anatase. The TiO2 nanosheets calcined at 500 °C exhibited the best activity for photo-degradation of organic dyes under UV light irradiation. The obtained photodetector exhibits excellent performance with a high photocurrent to dark current ratio and fast response and recovery times. Additionally, we demonstrated that the device may have potential applications in the future low-power optoelectronics system.Due to the large surface area-to-volume ratio and rapid electron transfer, two-dimensional (2D) TiO2 nanosheets with ultrathin thicknesses are synthesized by using a bottom-up strategy and these self-assembled nanosheet (NS)-based photocatalysts and photodetectors were explored for the first time. The influence of calcination temperature on microstructures and photocatalytic activity of TiO2 nanosheets were discovered and presented. The as-obtained TiO2 nanosheets were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Brunauer-Emmett-Teller (BET) analysis, Fourier transform infrared (FTIR) spectroscopy, UV-vis spectrophotometry, and X-ray photoelectron spectroscopy (XPS). The following

  18. Synthesis of Two-dimensional Microporous Carbonaceous Polymer Nanosheets and Their Application as High-performance CO2 Capture Sorbent.

    Science.gov (United States)

    Zhang, Miao; Liu, Lin; He, Teng; Wu, Guotao; Chen, Ping

    2016-06-21

    The synthesis of two-dimensional (2D) polymer nanosheets with a well-defined microporous structure remains challenging in materials science. Here, a new kind of 2D microporous carbonaceous polymer nanosheets was synthesized through polymerization of a very low concentration of 1,4-dicyanobenzene in molten zinc chloride at 400-500 °C. This type of nanosheets has a thickness in the range of 3-20 nm, well-defined microporosity, a high surface area (∼537 m(2)  g(-1) ), and a large micropore volume (∼0.45 cm(3)  g(-1) ). The microporous carbonaceous polymer nanosheets exhibit superior CO2 sorption capability (8.14 wt % at 298 K and 1 bar) and a relatively high CO2 selectivity toward N2 (25.6). Starting from different aromatic nitrile monomers, a variety of 2D carbonaceous polymer nanosheets can be obtained showing a certain universality of the ionothermal method reported herein.

  19. High-performance photodetectors and enhanced photocatalysts of two-dimensional TiO2 nanosheets under UV light excitation.

    Science.gov (United States)

    Yang, Jiao; Jiang, Yi-Lin; Li, Lin-Jie; Muhire, Elisée; Gao, Mei-Zhen

    2016-04-21

    Due to the large surface area-to-volume ratio and rapid electron transfer, two-dimensional (2D) TiO2 nanosheets with ultrathin thicknesses are synthesized by using a bottom-up strategy and these self-assembled nanosheet (NS)-based photocatalysts and photodetectors were explored for the first time. The influence of calcination temperature on microstructures and photocatalytic activity of TiO2 nanosheets were discovered and presented. The as-obtained TiO2 nanosheets were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Brunauer-Emmett-Teller (BET) analysis, Fourier transform infrared (FTIR) spectroscopy, UV-vis spectrophotometry, and X-ray photoelectron spectroscopy (XPS). The following heat treatment process induced phase evolution from rutile to anatase. The TiO2 nanosheets calcined at 500 °C exhibited the best activity for photo-degradation of organic dyes under UV light irradiation. The obtained photodetector exhibits excellent performance with a high photocurrent to dark current ratio and fast response and recovery times. Additionally, we demonstrated that the device may have potential applications in the future low-power optoelectronics system.

  20. High Performance Liquid Chromatography/Video Fluorometry. Part II. Applications.

    Science.gov (United States)

    1981-09-30

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY /VIDEO FLUOROMETRY. PART...REP«T_N&:-ŗ/ High Performance Liquid Chromatography /Video Fluorometry» Part II. Applications« by | Dennis C./Shelly* Michael P./Vogarty and...Data EnlirtdJ REPORT DOCUMENTATION PAGE t. REPORT NUMBER 2 GOVT ACCESSION NO 4. T1TI.F (and Submit) lP-^fffsyva High Performance Liquid Chromatography

  1. Supramolecular Nanocomposites: Dispersion of Zero-, One- and Two-dimensional Nanoparticles in Discotic Liquid Crystals

    Science.gov (United States)

    Kumar, Sandeep

    2016-04-01

    Discotic liquid crystals are emerging as novel nanomaterials useful in many device applications. Recently their hybridization with various zero-, one- and two- dimensional metallic and semiconducting nanoparticles has been realized to alter and improve their thermal, supramolecular and electronic properties. In this article, we have overviewed the work carried out in our laboratories on the dispersion of various metallic, semiconducting and carbon nanoparticles in discotic liquid crystals. First a brief introduction of self-organizing supramolecular liquid crystalline materials is presented with an emphasis on discotic liquid crystals. This is followed by the description of various discotic liquid crystal-nanoparticle hybrid systems. A number of discotic liquid crystals, functionalized nanoparticles and their nanocomposites were prepared and studied by spectroscopic and analytical tools. The dispersion of such functionalized nanomaterials in columnar matrix enhances the physical properties such as, conductivity, photoconductivity, absorbance, etc., significantly without disturbing the supramolecular properties.

  2. Two dimensional solids and liquids influenced by small and large substrate potential

    DEFF Research Database (Denmark)

    Vives, E.; Lindgård, Per-Anker

    1991-01-01

    A general, continuous model for two dimensional solids and liquids on a substrate is studied by means of Monte Carlo simulation. The results can be applied to the case of adsorbed atoms or molecules on surfaces as well as intercalated compounds. We have focused on the study of the melting...... experiments, in particular for weak potentials and large atomic mean square displacements. New results for large potentials are also presented and possible relations to the Potts lattice gas description studied....

  3. Wafer-scale two-dimensional semiconductors from printed oxide skin of liquid metals

    Science.gov (United States)

    Carey, Benjamin J.; Ou, Jian Zhen; Clark, Rhiannon M.; Berean, Kyle J.; Zavabeti, Ali; Chesman, Anthony S. R.; Russo, Salvy P.; Lau, Desmond W. M.; Xu, Zai-Quan; Bao, Qiaoliang; Kevehei, Omid; Gibson, Brant C.; Dickey, Michael D.; Kaner, Richard B.; Daeneke, Torben; Kalantar-Zadeh, Kourosh

    2017-02-01

    A variety of deposition methods for two-dimensional crystals have been demonstrated; however, their wafer-scale deposition remains a challenge. Here we introduce a technique for depositing and patterning of wafer-scale two-dimensional metal chalcogenide compounds by transforming the native interfacial metal oxide layer of low melting point metal precursors (group III and IV) in liquid form. In an oxygen-containing atmosphere, these metals establish an atomically thin oxide layer in a self-limiting reaction. The layer increases the wettability of the liquid metal placed on oxygen-terminated substrates, leaving the thin oxide layer behind. In the case of liquid gallium, the oxide skin attaches exclusively to a substrate and is then sulfurized via a relatively low temperature process. By controlling the surface chemistry of the substrate, we produce large area two-dimensional semiconducting GaS of unit cell thickness (~1.5 nm). The presented deposition and patterning method offers great commercial potential for wafer-scale processes.

  4. High-Performance Liquid Chromatography: An Overview

    OpenAIRE

    Tandia N; Singh SK1; Kumar N; Singh S

    2013-01-01

    Chromatography is considered extremely powerful separation technique for variety of samples. Thecommon feature of all these techniques is that the different components in a sample mixture aredistributed between two phases, one of which remains stationary while the other the mobile phase, runsthrough the interstices or over the surface of the fixed phase. The movement of the mobile phase resultsin differential migration of the sample components. High performance thin layer chromatography is an...

  5. Clustering behavior of solid particles in two-dimensional liquid-solid fluidized-beds

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    In this paper, the clustering behavior of solid particles in a two-dimensional (2D) liquid-solid fluidized-bed was studied by using the charge coupled devices (CCD) imaging measuring and processing technique and was characterized by fractal analysis. CCD images show that the distribution of solid particles in the 2D liquid-solid fluidised-bed is not uniform and self-organization behavior of solid particles was observed under the present experimental conditions. The solid particles move up in the 2D fluidized-bed in groups or clusters whose configurations are often in the form of horizontal strands. The box fractal dimension of the cluster images in the 2D liquid-solid fluidized-bed increases with the rising of solid holdup and reduces with the increment of solid particle diameter and superficial liquid velocity. At given solid holdup and solid particle size,the lighter particles show smaller fractal dimensions.

  6. Supramolecular [60]fullerene liquid crystals formed by self-organized two-dimensional crystals.

    Science.gov (United States)

    Zhang, Xiaoyan; Hsu, Chih-Hao; Ren, Xiangkui; Gu, Yan; Song, Bo; Sun, Hao-Jan; Yang, Shuang; Chen, Erqiang; Tu, Yingfeng; Li, Xiaohong; Yang, Xiaoming; Li, Yaowen; Zhu, Xiulin

    2015-01-02

    Fullerene-based liquid crystalline materials have both the excellent optical and electrical properties of fullerene and the self-organization and external-field-responsive properties of liquid crystals (LCs). Herein, we demonstrate a new family of thermotropic [60]fullerene supramolecular LCs with hierarchical structures. The [60]fullerene dyads undergo self-organization driven by π-π interactions to form triple-layer two-dimensional (2D) fullerene crystals sandwiched between layers of alkyl chains. The lamellar packing of 2D crystals gives rise to the formation of supramolecular LCs. This design strategy should be applicable to other molecules and lead to an enlarged family of 2D crystals and supramolecular liquid crystals.

  7. Detecting trace components in liquid chromatography/mass spectrometry data sets with two-dimensional wavelets

    Science.gov (United States)

    Compton, Duane C.; Snapp, Robert R.

    2007-09-01

    TWiGS (two-dimensional wavelet transform with generalized cross validation and soft thresholding) is a novel algorithm for denoising liquid chromatography-mass spectrometry (LC-MS) data for use in "shot-gun" proteomics. Proteomics, the study of all proteins in an organism, is an emerging field that has already proven successful for drug and disease discovery in humans. There are a number of constraints that limit the effectiveness of liquid chromatography-mass spectrometry (LC-MS) for shot-gun proteomics, where the chemical signals are typically weak, and data sets are computationally large. Most algorithms suffer greatly from a researcher driven bias, making the results irreproducible and unusable by other laboratories. We thus introduce a new algorithm, TWiGS, that removes electrical (additive white) and chemical noise from LC-MS data sets. TWiGS is developed to be a true two-dimensional algorithm, which operates in the time-frequency domain, and minimizes the amount of researcher bias. It is based on the traditional discrete wavelet transform (DWT), which allows for fast and reproducible analysis. The separable two-dimensional DWT decomposition is paired with generalized cross validation and soft thresholding. The Haar, Coiflet-6, Daubechie-4 and the number of decomposition levels are determined based on observed experimental results. Using a synthetic LC-MS data model, TWiGS accurately retains key characteristics of the peaks in both the time and m/z domain, and can detect peaks from noise of the same intensity. TWiGS is applied to angiotensin I and II samples run on a LC-ESI-TOF-MS (liquid-chromatography-electrospray-ionization) to demonstrate its utility for the detection of low-lying peaks obscured by noise.

  8. Substrate influence on two-dimensional solids and liquids: A Monte Carlo simulation study

    DEFF Research Database (Denmark)

    Vives, E.; Lindgård, Per-Anker

    1991-01-01

    A general model for two-dimensional solids and liquids on a substrate is studied by means of Monte Carlo simulation. The results can be applied to the case of adsorbed atoms or molecules on surfaces as well as intercalated compounds. We have focused on the study of the melting of a commensurate...... square-root 3 X square-root 3 structure on a triangular lattice with 1/3 coverage. The evolution of the energy, order parameters, and structure factor has been followed in a wide range of temperatures and substrate-potential strengths. The phase diagram exhibits a broad transition region between...

  9. The two-dimensional alternative binary L-J system: liquid-gas phase diagram

    Institute of Scientific and Technical Information of China (English)

    张陟; 陈立溁

    2003-01-01

    A two-dimensional (2D) binary system without considering the Lennard-Jones (L-J) potential has been studied by using the Collins model. In this paper, we introduce the L-J potential into the 2D binary system and consider the existence of the holes that are called the "molecular fraction". The liquid-gas phase diagram of the 2D alternative binary L-J system is obtained. The results are quite analogous to the behaviour of 3D substances.

  10. Coherent Two-Dimensional Infrared Spectroscopy of Vibrational Excitons in Hydrogen-Bonded Liquids

    Science.gov (United States)

    Paarmann, Alexander

    The structure and structural dynamics of hydrogen bonded liquids were studied experimentally and theoretically with coherent two-dimensional infrared (2DIR) spectroscopy. The resonant intermolecular interactions within the fully resonant hydrogen bond networks give access to spatial correlations in the dynamics of the liquid structures. New experimental and theoretical tools were developed that significantly reduced the technical challenges of these studies. A nanofluidic flow device was designed and manufactured providing sub-micron thin, actively stabilized liquid sample layers between similarly thin windows. A simulation protocol for nonlinear vibrational response calculations of disordered fluctuating vibrational excitons was developed that allowed for the first treatment of resonant intermolecular interactions in the 2DIR response of liquid water. The 2DIR spectrum of the O-H stretching vibration of pure liquid water was studied experimentally at different temperatures. At ambient conditions the loss of frequency correlations is extremely fast, and is attributed to very efficient modulations of the two-dimensional O-H stretching vibrational potential through librational motions in the hydrogen bond network. At temperatures near freezing, the librational motions are significantly reduced leading to a pronounced slowing down of spectral diffusion dynamics. Comparison with energy transfer time scales revealed the first direct proof of delocalization of the vibrational excitations. This work establishes a fundamentally new view of vibrations in liquid water by providing a spatial length scale of correlated hydrogen-bond motions. The linear and 2DIR response of the amide I mode in neat liquid formamide was found to be dominated by excitonic effects due to largely delocalized vibrational excitations. The spectral response and dynamics are very sensitive to the excitonic mode structure and infrared activity distributions, leading to a pronounced asymmetry of linear

  11. Simulation of two-dimensional adjustable liquid gradient refractive index (L-GRIN) microlens

    Science.gov (United States)

    Le, Zichun; Wu, Xiang; Sun, Yunli; Du, Ying

    2017-07-01

    In this paper, a two-dimensional liquid gradient refractive index (L-GRIN) microlens is designed which can be used in adjusting focusing direction and focal spot of light beam. Finite element method (FEM) is used to simulate the convection diffusion process happening in core inlet flow and cladding inlet flow. And the ray tracing method shows us the light beam focusing effect including the extrapolation of focal length and output beam spot size. When the flow rates of the core and cladding fluids are held the same between the internal and external, left and right, and upper and lower inlets, the focal length varied from 313 μm to 53.3 μm while the flow rate of liquids ranges from 500 pL/s to 10,000 pL/s. While the core flow rate is bigger than the cladding inlet flow rate, the light beam will focus on a light spot with a tunable size. By adjusting the ratio of cladding inlet flow rate including Qright/Qleft and Qup/Qdown, we get the adjustable two-dimensional focus direction rather than the one-dimensional focusing. In summary, by adjusting the flow rate of core inlet and cladding inlet, the focal length, output beam spot and focusing direction of the input light beam can be manipulated. We suppose this kind of flexible microlens can be used in integrated optics and lab-on-a-chip system.

  12. Characterization of sodium carboxymethyl cellulose by comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Shakun, Maria; Heinze, Thomas; Radke, Wolfgang

    2015-10-05

    Two series of sodium carboxymethyl celluloses (NaCMC) with average degrees of substitution (DS) ranging from 0.45 to 1.55 were synthesized from low molecular mass Avicel cellulose (Avicel samples) and from high molecular mass cotton linters (BWL samples). The samples were characterized by online two-dimensional liquid chromatography using gradient liquid adsorption chromatography in the first and size exclusion chromatography (SEC) in the second dimension. This method allows the simultaneous determination of the chemical composition (DS) and the molar mass distribution within the individual samples. Moreover information was obtained on the dependence of the elution volume in gradient chromatography on molar mass. As expected, evidence for a stronger influence of molar mass on gradient elution volume was found for the low molecular mass NaCMC as compared to the high molecular mass BWL samples. Finally the applicability of the method for the simultaneous separation of blends heterogeneous with respect to chemical composition (DS) and molar mass was demonstrated. Such blends cannot be efficiently separated by either SEC or gradient chromatography alone, nor by simply combining the results of both methods. Only the complete two-dimensional chromatogram can reveal the complexity of such blends, since it reveals the correlations between molar mass and chemical composition.

  13. Molecular shear heating and vortex dynamics in thermostatted two-dimensional Yukawa liquids

    CERN Document Server

    Gupta, Akanksha; Joy, Ashwin

    2016-01-01

    It is well known that two-dimensional macroscale shear flows are susceptible to instabilities leading to macroscale vortical structures. The linear and nonlinear fate of such a macroscale flow in a strongly coupled medium is a fundamental problem. A popular example of a strongly coupled medium is a dusty plasma, often modelled as a Yukawa liquid. Recently, laboratory experiments and MD studies of shear flows in strongly coupled Yukawa liquids, indicated occurrence of strong molecular shear heating, which is found to reduce the coupling strength exponentially leading to destruction of macroscale vorticity. To understand the vortex dynamics of strongly coupled molecular fluids undergoing macroscale shear flows and molecular shear heating, MD simulation has been performed, which allows the macroscopic vortex dynamics to evolve while at the same time, "removes" the microscopically generated heat without using the velocity degrees of freedom. We demonstrate that by using a configurational thermostat in a novel way...

  14. ANALYSIS OF AMINO ACIDS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    Qurat E Noor Baig

    2016-06-01

    Full Text Available Amino acids are the building blocks of proteins and are considered as the key precursors for the formation of hormones and low molecular weight nitrogenous substances with biological importance. Since the analysis of amino acids has been carried out for both qualitative and quantitative purposes with an aim to study their levels in the plasma concentration, the quantitative determination, in particular, also helps in the diagnosis of different diseases associated with their deficiency. This review article deals with the determination of amino acids by chromatographic methods which include ion-exchange chromatography (IEC, high performance liquid chromatography (HPLC, reverse phase-high performance liquid chromatography (RP-HPLC and ultra-performance liquid chromatography (UPLC. The review will also give an idea for the preparation of samples, derivatization methods for the analysis of amino acids (direct and indirect methods and separation of amino acids by high performance liquid chromatographic technique.

  15. Impact of reversed phase column pairs in comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Allen, Robert C; Barnes, Brian B; Haidar Ahmad, Imad A; Filgueira, Marcelo R; Carr, Peter W

    2014-09-26

    A major issue in optimizing the resolving power of two-dimensional chromatographic separations is the choice of the two phases so as to maximize the distribution of the analytes over the separation space. In this work, we studied the choice of appropriate reversed phases to use in on-line comprehensive two-dimensional liquid chromatography (LC×LC). A set of four chemically different conventional bonded reversed phases was used in the first dimension. The second dimension column was either a conventional bonded C18 phase or a carbon-clad phase (CCP). The LC×LC chromatograms and contour plots were all rather similar indicating that the selectivities of the two phases were also similar regardless of the reverse phase column used in the first dimension. Further, the spatial coverage seen with all four first dimension stationary phases when paired with a second dimension C18 phase were low and the retention times were strongly correlated. However, when the C18 column was replaced with the CCP column much improved separations were observed with higher spatial coverages, greater orthogonalities and significant increases in the number of observed peaks.

  16. Smart templates for peak pattern matching with comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Reichenbach, Stephen E; Carr, Peter W; Stoll, Dwight R; Tao, Qingping

    2009-04-17

    Comprehensive two-dimensional liquid chromatography (LCxLC) generates information-rich but complex peak patterns that require automated processing for rapid chemical identification and classification. This paper describes a powerful approach and specific methods for peak pattern matching to identify and classify constituent peaks in data from LCxLC and other multidimensional chemical separations. The approach records a prototypical pattern of peaks with retention times and associated metadata, such as chemical identities and classes, in a template. Then, the template pattern is matched to the detected peaks in subsequent data and the metadata are copied from the template to identify and classify the matched peaks. Smart Templates employ rule-based constraints (e.g., multispectral matching) to increase matching accuracy. Experimental results demonstrate Smart Templates, with the combination of retention-time pattern matching and multispectral constraints, are accurate and robust with respect to changes in peak patterns associated with variable chromatographic conditions.

  17. Electron spin resonance in a two-dimensional Fermi liquid with spin-orbit coupling

    Science.gov (United States)

    Maiti, Saurabh; Imran, Muhammad; Maslov, Dmitrii L.

    2016-01-01

    Electron spin resonance (ESR) is usually viewed as a single-particle phenomenon protected from the effect of many-body correlations. We show that this is not the case in a two-dimensional Fermi liquid (FL) with spin-orbit coupling (SOC). Depending on whether the in-plane magnetic field is below or above some critical value, ESR in such a system probes up to three chiral-spin collective modes, augmented by the spin mode in the presence of the field, or the Silin-Leggett mode. All the modes are affected by both SOC and FL renormalizations. We argue that ESR can be used as a probe not only for SOC but also for many-body physics.

  18. Reproducibility of retention time and peak area in comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Elsner, Victoria; Wulf, Volker; Wirtz, Michaela; Schmitz, Oliver J

    2015-01-01

    Comprehensive two-dimensional liquid chromatography is used to separate anionic, nonionic, and amphoteric surfactants by substance class, alkyl chain distribution, and degree of ethoxylation. A nearly orthogonal system with a hydrophilic interaction chromatography (HILIC) phase in the first and a reversed-phase material in the second dimension is applied to generate a separation with maximum peak capacity. The potential of the developed method is demonstrated by the reproducibility of retention time and peak area, which shows standard deviations less than 5 % and the analysis of real samples. An external calibration and the standard addition method were applied to determine unknown concentrations for the alkyl chain homologues of a betaine and for one ethoxylate (EO) homologue of a fatty alcohol ethoxylate in a sample mixture.

  19. Topological Aspect and Bifurcation of Disclination Lines in Two-Dimensional Liquid Crystals

    Institute of Scientific and Technical Information of China (English)

    YANG Guo-Hong; ZHANG Hui; DUAN Yi-Shi

    2002-01-01

    Using φ-mapping method and topological current theory, the topological structure and bifurcation ofdisclination lines in two-dimensional liquid crystals are studied. By introducing the strength density and the topologicalcurrent of many disclination lines, the total disclination strength is topologically quantized by the Hopf indices andBrouwer degrees at the singularities of the director field when the Jacobian determinant of director field does not vanish.When the Jacobian determinant vanishes, the origin, annihilation and bifurcation processes of disclination lines arestudied in the neighborhoods of the limit points and bifurcation points, respectively. The branch solutions at the limitpoint and the different directions of all branch curves at the bifurcation point are calculated with the conservation lawof the topological quantum numbers. It is pointed out that a disclination line with a higher strength is unstable and itwill evolve to the lower strength state through the bifurcation process.

  20. Numerical experiment of thermal conductivity in two-dimensional Yukawa liquids

    Energy Technology Data Exchange (ETDEWEB)

    Shahzad, Aamir, E-mail: aamirshahzad-8@hotmail.com [Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education (MOE), Xi' an Jiaotong University, Xi' an 710049 (China); Department of Physics, Government College University Faisalabad (GCUF), Allama Iqbal Road, Faisalabad 38000 (Pakistan); He, Mao-Gang, E-mail: mghe@mail.xjtu.edu.cn [Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education (MOE), Xi' an Jiaotong University, Xi' an 710049 (China)

    2015-12-15

    A newly improved homogenous nonequilibrium molecular dynamics simulation (HNEMDS) method, proposed by the Evans, has been used to compute the thermal conductivity of two-dimensional (2D) strongly coupled complex (dusty) plasma liquids (SCCDPLs), for the first time. The effects of equilibrium external field strength along with different system sizes and plasma states (Γ, κ) on the thermal conductivity of SCCDPLs have been calculated using an enhanced HNEMDS method. A simple analytical temperature representation of Yukawa 2D thermal conductivity with appropriate normalized frequencies (plasma and Einstein) has also been calculated. The new HNEMDS algorithm shows that the present method provides more accurate results with fast convergence and small size effects over a wide range of plasma states. The presented thermal conductivity obtained from HNEMDS method is found to be in very good agreement with that obtained through the previously known numerical simulations and experimental results for 2D Yukawa liquids (SCCDPLs) and with the three-dimensional nonequilibrium molecular dynamics simulation (MDS) and equilibrium MDS calculations. It is shown that the HNEMDS algorithm is a powerful tool, making the calculations very efficient and can be used to predict the thermal conductivity in 2D Yukawa liquid systems.

  1. Two-dimensional pattern formation in ionic liquids confined between graphene walls.

    Science.gov (United States)

    Montes-Campos, Hadrián; Otero-Mato, José Manuel; Méndez-Morales, Trinidad; Cabeza, Oscar; Gallego, Luis J; Ciach, Alina; Varela, Luis M

    2017-09-20

    We perform molecular dynamics simulations of ionic liquids confined between graphene walls under a large variety of conditions (pure ionic liquids, mixtures with water and alcohols, mixtures with lithium salts and defective graphene walls). Our results show that the formation of striped and hexagonal patterns in the Stern layer can be considered as a general feature of ionic liquids at electrochemical interfaces, the transition between patterns being controlled by the net balance of charge in the innermost layer of adsorbed molecules. This explains previously reported experimental and computational results and, for the first time, why these pattern changes are triggered by any perturbation of the charge density at the innermost layer of the electric double layer (voltage and composition changes, and vacancies at the electrode walls, among others), which may help tuning electrode-ionic liquid interfaces. Using Monte Carlo simulations we show that such structures can be reproduced by a simple two-dimensional lattice model with only nearest-neighbour interactions, governed by highly screened ionic interactions and short-range and excluded volume interactions. We also show that the results of our simulations are consistent with those inferred from the Landau-Brazovskii theory of pattern formation in self-assembling systems. The presence of these patterns at the ionic liquid graphene-electrode interfaces may have a strong impact on the process of ionic transfer from the bulk mixtures to the electrodes, on the differential capacitance of the electrode-electrolyte double layer or on the rates of redox reactions at the electrodes, among other physicochemical properties, and is therefore an effect of great technological interest.

  2. An equation for pressure of a two-dimensional Yukawa liquid

    Science.gov (United States)

    Feng, Yan; Li, Wei; Wang, Qiaoling; Lin, Wei; Goree, John; Liu, Bin

    2016-10-01

    Thermodynamic behavior of two-dimensional (2D) dusty plasmas has been studied experimentally and theoretically recently. As a crucial parameter in thermodynamics, the pressure of dusty plasmas arises from frequent collisions of individual dust particles. Here, equilibrium molecular dynamical simulations were performed to study the pressure of 2D Yukawa liquids. A simple analytical expression for the pressure of a 2D Yukawa liquid is found by fitting the obtained pressure data over a wide range of temperatures, from the coldest close to the melting point, to the hottest about 70 times higher than the melting points. The obtained expression verifies that the pressure can be written as the sum of a potential term which is a simple multiple of the Coulomb potential energy at a distance of Wigner-Seitz radius, and a kinetic term which is a multiple of the one for an ideal gas. Dimensionless coefficients for each of these terms are found empirically, by fitting. The resulting analytical expression, with its empirically determined coefficients, is plotted as isochors, or curves of constant area. These results should be applicable to 2D dusty plasmas. Work in China supported by by the National Natural Science Foundation of China under Grant No. 11505124, the 1000 Youth Talents Plan, and startup funds from Soochow University. Work in the US supported by DOE & NSF.

  3. Two-dimensional NMR investigations of the dynamic conformations of phospholipids and liquid crystals

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Mei [Univ. of California, Berkeley, CA (United States). Applied Science and Technology

    1996-05-01

    Two-dimensional 13C, 1H, and 31P nuclear magnetic resonance (NMR) techniques are developed and used to study molecular structure and dynamics in liquid-crystalline systems, primarily phospholipids and nematic liquid crystals. NMR spectroscopy characterizes molecular conformation in terms of orientations and distances of molecular segments. In anisotropically mobile systems, this is achieved by measuring motionally-averaged nuclear dipolar couplings and chemical shift anisotropies. The short-range couplings yield useful bond order parameters, while the long-range interactions constrain the overall conformation. In this work, techniques for probing proton dipolar local fields are further developed to obtain highlyresolved dipolar couplings between protons and rare spins. By exploiting variable-angle sample spinning techniques, orientation-sensitive NMR spectra are resolved according to sitespecific isotropic chemical shifts. Moreover, the signs and magnitudes of various short-range dipolar couplings are obtained. They are used in novel theoretical analyses that provide information about segmental orientations and their distributions. Such information is obtained in a model-independent fashion or with physically reasonable assumptions. The structural investigation of phospholipids is focused on the dynam

  4. Electrically tunable two-dimensional holographic polymer-dispersed liquid crystal grating with variable period

    Science.gov (United States)

    Wang, Kangni; Zheng, Jihong; Liu, Yourong; Gao, Hui; Zhuang, Songlin

    2017-06-01

    An electrically tunable two-dimensional (2D) holographic polymer-dispersed liquid crystal (H-PDLC) grating with variable period was fabricated by inserting a cylindrical lens in a conventional holographic interference beam. The interference between the plane wave and cylindrical wave resulting in varying intersection angles on the sample, combined with dual exposure along directions perpendicular to each other, generates a 2D H-PDLC grating with varied period. We have identified periods varying from 3.109 to 5.158 μm across a 16 mm width, with supporting theoretical equations for the period. The period exhibits a symmetrical square lattice in a diagonal direction, with an asymmetrical rectangular lattice in off-diagonal locations. With the first exposure at 2 s and the second exposure at 60 s, the phase separation between the prepolymer and liquid crystal was most evident. The diffraction properties and optic-electric characteristics were also studied. The diffraction efficiency of first-order light was observed to be 13.5% without external voltage, and the transmission efficiency of non-diffracted light was 78% with an applied voltage of 100 V. The proposed method provides the capability of generating period variation to the conventional holographic interference path, with potential application in diffractive optics such as tunable multi-wavelength organic lasing from a dye-doped 2D H-PDLC grating.

  5. Mallow carotenoids determined by high-performance liquid chromatography

    Science.gov (United States)

    Mallow (corchorus olitorius) is a green vegetable, which is widely consumed either fresh or dry by Middle East population. This study was carried out to determine the contents of major carotenoids quantitatively in mallow, by using a High Performance Liquid Chromatography (HPLC) equipped with a Bis...

  6. Determination of Caffeine in Beverages by High Performance Liquid Chromatography.

    Science.gov (United States)

    DiNunzio, James E.

    1985-01-01

    Describes the equipment, procedures, and results for the determination of caffeine in beverages by high performance liquid chromatography. The method is simple, fast, accurate, and, because sample preparation is minimal, it is well suited for use in a teaching laboratory. (JN)

  7. Multichannel Detection in High-Performance Liquid Chromatography.

    Science.gov (United States)

    Miller, James C.; And Others

    1982-01-01

    A linear photodiode array is used as the photodetector element in a new ultraviolet-visible detection system for high-performance liquid chromatography (HPLC). Using a computer network, the system processes eight different chromatographic signals simultaneously in real-time and acquires spectra manually/automatically. Applications in fast HPLC…

  8. High-Performance Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Vestal, Marvin L.

    1984-01-01

    Reviews techniques for online coupling of high-performance liquid chromatography with mass spectrometry, emphasizing those suitable for application to nonvolatile samples. Also summarizes the present status, strengths, and weaknesses of various techniques and discusses potential applications of recently developed techniques for combined liquid…

  9. Analysis of Tocopherols by High Performance Liquid Chromatography

    OpenAIRE

    Edison, B.

    2009-01-01

    : Gas chromatography is the key technique for organic components and also for tocopherols analysis. High performance liquid chromatography has an important role to take part in applications such as the handling of less usual samples, prevention of degradation of heat sensitive functional groups and for micro preparative purposes. Many approaches for development of improved methods are suggested, especially for reversed phase applications.

  10. Ultra high performance liquid chromatography of seized drugs

    NARCIS (Netherlands)

    Lurie, I.S.

    2010-01-01

    The primary goal of this thesis is to investigate the use of ultra high performance liquid chromatography (UHPLC) for the analysis of seized drugs. This goal was largely achieved and significant progress was made in achieving improved separation and detection of drugs of forensic interest.

  11. Quantification of Tea Flavonoids by High Performance Liquid Chromatography

    Science.gov (United States)

    Freeman, Jessica D.; Niemeyer, Emily D.

    2008-01-01

    We have developed a laboratory experiment that uses high performance liquid chromatography (HPLC) to quantify flavonoid levels in a variety of commercial teas. Specifically, this experiment analyzes a group of flavonoids known as catechins, plant-derived polyphenolic compounds commonly found in many foods and beverages, including green and black…

  12. Resolution of RNA using high-performance liquid chromatography

    NARCIS (Netherlands)

    Mclaughlin, L.W.; Bischoff, Rainer

    1987-01-01

    High-performance liquid chromatographic techniques can be very effective for the resolution and isolation of nucleic acids. The characteristic ionic (phosphodiesters) and hydrophobic (nucleobases) properties of RNAs can be exploited for their separation. In this respect anion-exchange and reversed-p

  13. A two-dimensional algebraic quantum liquid produced by an atomic simulator of the quantum Lifshitz model.

    Science.gov (United States)

    Po, Hoi Chun; Zhou, Qi

    2015-08-13

    Bosons have a natural instinct to condense at zero temperature. It is a long-standing challenge to create a high-dimensional quantum liquid that does not exhibit long-range order at the ground state, as either extreme experimental parameters or sophisticated designs of microscopic Hamiltonians are required for suppressing the condensation. Here we show that synthetic gauge fields for ultracold atoms, using either the Raman scheme or shaken lattices, provide physicists a simple and practical scheme to produce a two-dimensional algebraic quantum liquid at the ground state. This quantum liquid arises at a critical Lifshitz point, where a two-dimensional quartic dispersion emerges in the momentum space, and many fundamental properties of two-dimensional bosons are changed in its proximity. Such an ideal simulator of the quantum Lifshitz model allows experimentalists to directly visualize and explore the deconfinement transition of topological excitations, an intriguing phenomenon that is difficult to access in other systems.

  14. Coarse-grained single-particle dynamics in two-dimensional solids and liquids.

    Science.gov (United States)

    Silbermann, Jörg R; Schoen, Martin; Klapp, Sabine H L

    2008-07-01

    We consider the dynamics of a single tagged particle in a two-dimensional system governed by Lennard-Jones interactions. Previous work based on the Mori-Zwanzig projection operator formalism has shown that the single-particles dynamics can be described via a generalized Langevin equation (GLE) which is exact within the harmonic approximation, that is, for a low-temperature solid [J. M. Deutch and R. Silbey, Phys. Rev. A 3, 2049 (1971)]. In the present work we explore to what an extent the GLE reproduces the effective dynamics under thermodynamic conditions where the harmonic approximation is no longer justified. To this end we compute characteristic time autocorrelation functions for the tagged particle in molecular dynamics simulations of the full system and compare these functions with those obtained from solving the GLE. At low temperatures we find excellent agreement between both data sets. Deviations emerge at higher temperatures which are, however, surprisingly small even in the high-temperature liquid phase.

  15. Metabolome analysis via comprehensive two-dimensional liquid chromatography: identification of modified nucleosides from RNA metabolism.

    Science.gov (United States)

    Willmann, Lucas; Erbes, Thalia; Krieger, Sonja; Trafkowski, Jens; Rodamer, Michael; Kammerer, Bernd

    2015-05-01

    Modified nucleosides derived from the RNA metabolism constitute an important chemical class, which are discussed as potential biomarkers in the detection of mammalian breast cancer. Not only the variability of modifications, but also the complexity of biological matrices such as urinary samples poses challenges in the analysis of modified nucleosides. In the present work, a comprehensive two-dimensional liquid chromatography mass spectrometry (2D-LC-MS) approach for the analysis of modified nucleosides in biological samples was established. For prepurification of urinary samples and cell culture supernatants, we performed a cis-diol specific affinity chromatography using boronate-derivatized polyacrylamide gel. In order to establish a 2D-LC method, we tested numerous column combinations and chromatographic conditions. In order to determine the target compounds, we coupled the 2D-LC setup to a triple quadrupole mass spectrometer performing full scans, neutral loss scans, and multiple reaction monitoring (MRM). The combination of a Zorbax Eclipse Plus C18 column with a Zorbax Bonus-RP column was found to deliver a high degree of orthogonality and adequate separation. By application of 2D-LC-MS approaches, we were able to detect 28 target compounds from RNA metabolism and crosslinked pathways in urinary samples and 26 target compounds in cell culture supernatants, respectively. This is the first demonstration of the applicability and benefit of 2D-LC-MS for the targeted metabolome analysis of modified nucleosides and compounds from crosslinked pathways in different biological matrices.

  16. Ground-state and dynamical properties of two-dimensional dipolar Fermi liquids

    Science.gov (United States)

    Abedinpour, Saeed H.; Asgari, Reza; Tanatar, B.; Polini, Marco

    2014-01-01

    We study the ground-state properties of a two-dimensional spin-polarized fluid of dipolar fermions within the Euler-Lagrange Fermi-hypernetted-chain approximation. Our method is based on the solution of a scattering Schrödinger equation for the "pair amplitude" g(r), where g(r) is the pair distribution function. A key ingredient in our theory is the effective pair potential, which includes a bosonic term from Jastrow-Feenberg correlations and a fermionic contribution from kinetic energy and exchange, which is tailored to reproduce the Hartree-Fock limit at weak coupling. Very good agreement with recent results based on quantum Monte Carlo simulations is achieved over a wide range of coupling constants up to the liquid-to-crystal quantum phase transition. Using the fluctuation-dissipation theorem and a static approximation for the effective inter-particle interactions, we calculate the dynamical density-density response function, and furthermore demonstrate that an undamped zero-sound mode exists for any value of the interaction strength, down to infinitesimally weak couplings.

  17. Two-Dimensional Bipyramid Plasmonic Nanoparticle Liquid Crystalline Superstructure with Four Distinct Orientational Packing Orders.

    Science.gov (United States)

    Shi, Qianqian; Si, Kae Jye; Sikdar, Debabrata; Yap, Lim Wei; Premaratne, Malin; Cheng, Wenlong

    2016-01-26

    Anisotropic plasmonic nanoparticles have been successfully used as constituent elements for growing ordered nanoparticle arrays. However, orientational control over their spatial ordering remains challenging. Here, we report on a self-assembled two-dimensional (2D) nanoparticle liquid crystalline superstructure (NLCS) from bipyramid gold nanoparticles (BNPs), which showed four distinct orientational packing orders, corresponding to horizontal alignment (H-NLCS), circular arrangement (C-NLCS), slanted alignment (S-NLCS), and vertical alignment (V-NLCS) of constituent particle building elements. These packing orders are characteristic of the unique shape of BNPs because all four packing modes were observed for particles with various sizes. Nevertheless, only H-NLCS and V-NLCS packing orders were observed for the free-standing ordered array nanosheets formed from a drying-mediated self-assembly at the air/water interface of a sessile droplet. This is due to strong surface tension and the absence of particle-substrate interaction. In addition, we found the collective plasmonic coupling properties mainly depend on the packing type, and characteristic coupling peak locations depend on particle sizes. Interestingly, surface-enhanced Raman scattering (SERS) enhancements were heavily dependent on the orientational packing ordering. In particular, V-NLCS showed the highest Raman enhancement factor, which was about 77-fold greater than the H-NLCS and about 19-fold greater than C-NLCS. The results presented here reveal the nature and significance of orientational ordering in controlling plasmonic coupling and SERS enhancements of ordered plasmonic nanoparticle arrays.

  18. Analysis of fatty alcohol derivatives with comprehensive two-dimensional liquid chromatography coupled with mass spectrometry.

    Science.gov (United States)

    Elsner, Victoria; Laun, Sabrina; Melchior, David; Köhler, Michael; Schmitz, Oliver J

    2012-12-14

    A simultaneous separation of anionic (fatty alcohol sulfates, fatty alcohol ether sulfates), non-ionic (alkyl polyglucosides, fatty alcohol ethoxylates) and amphoteric (cocamidopropyl betaines) surfactants was performed by comprehensive two-dimensional liquid chromatography (LCxLC) utilizing a ZIC(®)-HILIC column in the first dimension, a Reprosphere 100 C8-Aqua column in the second dimension and a 10-port two position valve as the interface. The volume of the two sample loops were 25 or 50 μL and allow a one or two minute modulation at a 25 μL/min flow rate. In the first dimension, a gradient of acetonitrile and an ammonium acetate buffer was used to separate polyethoxylated surfactants by their degree of ethoxylation (EO number) whereas in the second dimension, a separation by alkyl chain was performed using a methanol/ammonium acetate buffer gradient. A baseline separation of the above mentioned surfactants according to both EO number and alkyl chain was achieved. The best performance was used to compare two different LCxLC-QTOF MS systems, which demonstrate that a transfer of the method from one system to a totally different system is possible. However, because of the differences in delay volume and extra-column volume between these systems the separation power is changed.

  19. Characterization of hydroxypropylmethylcellulose (HPMC) using comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Greiderer, Andreas; Steeneken, Linda; Aalbers, Tom; Vivó-Truyols, Gabriel; Schoenmakers, Peter

    2011-08-26

    Various hydroxyl-propylmethylcellulose (HPMC) polymers were characterized according to size and compositional distributions (percentage of methoxyl and hydroxyl-propoxyl substitution) by means of comprehensive two-dimensional liquid chromatography (LC×LC) using reversed-phase (RP) liquid chromatography in the first dimension and aqueous size-exclusion chromatography (aq-SEC) in the second dimension. RP separation was carried out in gradient-elution mode applying 0.05% TFA in water and 1-propanol, while 0.05% TFA in water was used as mobile phase in aqueous SEC. A two-position ten-port switching valve equipped with two storage loops was used to realize LC×LC. Detection of HPMC was accomplished by charged-aerosol detection (CAD). Data processing to visualize chromatograms was carried out using Matlab software. The significant influence of the LC×LC temperature on (the retention of) HPMC was studied using a column oven which allowed accurate temperature control. Due to the phenomenon of thermal gelation, which is a result of methyl and hydroxypropyl substitution of anhydroglucose units from the cellulose backbone, we were able to obtain additional, specific information on compositional characteristics of various HPMC samples. As the retention behaviour of gelated and non-gelated polymer proved to be different, the fraction of the polymer that is gelated in the chromatographic column could be monitored at different temperatures. Moreover, the temperature at which half of the polymer is gelated could be correlated with the cloud-point temperature. As a result, differences in inherent cloud points of modified cellulose can be used as a further distinguishing property in "temperature-responsive" LC×LC.

  20. Temperature-Modulated Array High-Performance Liquid Chromatography

    OpenAIRE

    Premstaller, Andreas; Xiao, Wenzhong; Oberacher, Herbert; O'Keefe, Matthew; Stern, David; Willis, Thomas; Huber, Christian G.; Peter J. Oefner

    2001-01-01

    Using novel monolithic poly(styrene-divinylbenzene) capillary columns with an internal diameter of 0.2 mm, we demonstrate for the first time the feasibility of constructing high-performance liquid chromatography arrays for the detection of mutations by heteroduplex analysis under partially denaturing conditions. In one embodiment, such an array can be used to analyze one sample simultaneously at different temperatures to maximize the detection of mutations in DNA fragments containing multiple...

  1. Analysis of Tocopherols by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    B. Edison

    2009-01-01

    Full Text Available : Gas chromatography is the key technique for organic components and also for tocopherols analysis. High performance liquid chromatography has an important role to take part in applications such as the handling of less usual samples, prevention of degradation of heat sensitive functional groups and for micro preparative purposes. Many approaches for development of improved methods are suggested, especially for reversed phase applications.

  2. Double Off-line Two-dimensional Liquid Chromatography for Separation and Identification of Compounds in Salvia Miltiorrhiza (Danshen

    Directory of Open Access Journals (Sweden)

    Ji-xia Wang

    2015-07-01

    Full Text Available Background: Danshen is an important traditional Chinese medicine (TCM used for the treatment of cardiovascular and cerebrovascular diseases. Separation and analysis of its components have been widely investigated. However, the systematical two dimensional liquid chromatography (2D-LC methods have not been developed to comprehensively separate and characterize its components.

  3. Anharmonic exciton dynamics and energy dissipation in liquid water from two-dimensional infrared spectroscopy

    Science.gov (United States)

    De Marco, Luigi; Fournier, Joseph A.; Thämer, Martin; Carpenter, William; Tokmakoff, Andrei

    2016-09-01

    Water's extended hydrogen-bond network results in rich and complex dynamics on the sub-picosecond time scale. In this paper, we present a comprehensive analysis of the two-dimensional infrared (2D IR) spectrum of O-H stretching vibrations in liquid H2O and their interactions with bending and intermolecular vibrations. By exploring the dependence of the spectrum on waiting time, temperature, and laser polarization, we refine our molecular picture of water's complex ultrafast dynamics. The spectral evolution following excitation of the O-H stretching resonance reveals vibrational dynamics on the 50-300 fs time scale that are dominated by intermolecular delocalization. These O-H stretch excitons are a result of the anharmonicity of the nuclear potential energy surface that arises from the hydrogen-bonding interaction. The extent of O-H stretching excitons is characterized through 2D depolarization measurements that show spectrally dependent delocalization in agreement with theoretical predictions. Furthermore, we show that these dynamics are insensitive to temperature, indicating that the exciton dynamics alone set the important time scales in the system. Finally, we study the evolution of the O-H stretching mode, which shows highly non-adiabatic dynamics suggestive of vibrational conical intersections. We argue that the so-called heating, commonly observed within ˜1 ps in nonlinear IR spectroscopy of water, is a nonequilibrium state better described by a kinetic temperature rather than a Boltzmann distribution. Our conclusions imply that the collective nature of water vibrations should be considered in describing aqueous solvation.

  4. SYNTHESIS AND CHARACTERIZATION OF LIQUID CRYSTAL POLYMERS WITH T-SHAPED TWO-DIMENSIONAL MESOGENIC UNITS (Ⅱ)

    Institute of Scientific and Technical Information of China (English)

    LI Zifa; ZHENG Shijun; ZHANG Shuyuan; CAO Shaokui; LI Lei; LIU Guangsheng; ZHOU Qifeng

    1997-01-01

    A series of liquid crystalline polymers with T-shaped two-dimensional mesogenic units were synthesized via low temperature solution polycondensation of 2-(4'-alkoxy-phenyl) hydroquinone with various diacyl dichlorides. The polymers were found to be nematic and shown thermotropic liquid crystalline behaviors through observations using DSC, polarized microscopy and X-ray diffraction. The melting temperature Tm and the isotropization temperature Ti of the polymers change regularly with varying of the monomer structures.

  5. Full molecular dynamics simulations of liquid water and carbon tetrachloride for two-dimensional Raman spectroscopy in the frequency domain

    CERN Document Server

    Jo, Ju-Yeon; Tanimura, Yoshitaka

    2016-01-01

    Frequency-domain two-dimensional Raman signals, which are equivalent to coherent two-dimensional Raman scattering (COTRAS) signals, for liquid water and carbon tetrachloride were calculated using an equilibrium-nonequilibrium hybrid MD simulation algorithm. We elucidate mechanisms governing the 2D signal pro?les involving anharmonic mode-mode coupling and the nonlinearities of the polarizability for the intermolecular and intramolecular vibrational modes. The predicted signal pro?les and intensities can be utilized to analyze recently developed single-beam 2D spectra, whose signals are generated from a coherently controlled pulse, allowing the single-beam measurement to be carried out more efficiently.

  6. Trends in High Performance Liquid Chromatography for Cultural Heritage.

    Science.gov (United States)

    Degano, Ilaria; La Nasa, Jacopo

    2016-04-01

    The separation, detection and quantitation of specific species contained in a sample in the field of Cultural Heritage requires selective, sensitive and reliable methods. Procedures based on liquid chromatography fulfil these requirements and offer a wide range of applicability in terms of analyte types and concentration range. The main applications of High Performance Liquid Chromatography in this field are related to the separation and detection of dyestuffs in archaeological materials and paint samples by reversed-phase liquid chromatography with suitable detectors. The relevant literature will be revised, with particular attention to sample treatment strategies and future developments. Reversed phase chromatography has also recently gained increasing importance in the analysis of lipid binders and lipid materials in archaeological residues: the main advantages and disadvantages of the new approaches will be discussed. Finally, the main applications of ion chromatography and size exclusion chromatography in the field of Cultural Heritage will be revised in this chapter.

  7. Comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for analysis of toad skin.

    Science.gov (United States)

    Li, Jia-Fu; Yan, Xia; Wu, Yun-Long; Fang, Mei-Juan; Wu, Zhen; Qiu, Ying-Kun

    2017-04-15

    An analytical two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was constructed with a newly developed thermal evaporation assisted adsorption (TEAA) interface. This novel TEAA interface with heating temperature above solvent boiling point allowed fast removal of organic NPLC solvent and successfully solved the solvent incompatibility problem between NPLC and RPLC. The system achieved rapid on-line solvent exchange between the two dimensions within a short modulation time of 190 s and was applied in the analysis of an extract from the skin of Bufo bufo gargarizans. This is the first time to realize the on-line comprehensive analysis of a moderate polar natural product by coupling NPLC with reversed phase ultra-high performance liquid chromatography (UHPLC). To be highlighted, with the TEAA interface, the 2D NPLC × RPLC system provided excellent resolution and orthogonality (75.2%), when compared with that of 2D RPLC × RPLC.

  8. The analysis of carbohydrates in milk powder by a new "heart-cutting" two-dimensional liquid chromatography method.

    Science.gov (United States)

    Ma, Jing; Hou, Xiaofang; Zhang, Bing; Wang, Yunan; He, Langchong

    2014-03-01

    In this study, a new"heart-cutting" two-dimensional liquid chromatography method for the simultaneous determination of carbohydrate contents in milk powder was presented. In this two dimensional liquid chromatography system, a Venusil XBP-C4 analysis column was used in the first dimension ((1)D) as a pre-separation column, a ZORBAX carbohydrates analysis column was used in the second dimension ((2)D) as a final-analysis column. The whole process was completed in less than 35min without a particular sample preparation procedure. The capability of the new two dimensional HPLC method was demonstrated in the determination of carbohydrates in various brands of milk powder samples. A conventional one dimensional chromatography method was also proposed. The two proposed methods were both validated in terms of linearity, limits of detection, accuracy and precision. The comparison between the results obtained with the two methods showed that the new and completely automated two dimensional liquid chromatography method is more suitable for milk powder sample because of its online cleanup effect involved.

  9. Thermal expansion pump for capillary high-performance liquid chromatography.

    Science.gov (United States)

    Tao, Qian; Wu, Qian; Zhang, Xiangmin

    2010-02-01

    A thermal expansion pump (TEP) based on a principle of liquid thermal expansion for capillary high-performance liquid chromatography has been developed. The novel pump is capable of generating a continuous flow at high pressure for constant and stable delivery of binary solvents from nanoliters to microliters per minute without splitting. Theoretical equations for controlling fluidic output of this pump have been established and validated by a series of experiments. Factors affecting flow rate, such as density discrepancy, liquid compressibility, and mass loss in output, were taken into account. An assembly of the pump system employing two groups of thermal expansion pumps (TEPs) working in turns were fabricated, and a controlling strategy for the pump system to maintain a continuous delivery without pressure fluctuation even at switching points was also developed. Both isocratic and gradients of binary solvent delivery by the TEPs were performed. Reproducibility and standard deviation at different flow rates were determined. A capillary high-performance liquid chromatography (micro-HPLC) system consisting of the TEPs, an injection valve, a homemade packed capillary column (20 cm x 100 microm i.d. with 5 microm C18), and a laser-induced fluorescence detector was set up, and sample separations were carried out. Results of RSD = 4% for flow and RSD = 2% for retention times at 500 nL/min were achieved. Such a pump system has almost no moving parts except for the solvent switches. Its overall costs of manufacture and running are very low. It is proven that the TEPs system has great potential and competitive capabilities in capillary liquid chromatography.

  10. Quantification of tryptophan in plasma by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Renata Romanholi Pinhati

    2012-01-01

    Full Text Available A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v. The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.

  11. Gas and high-performance liquid chromatography of phenols

    Energy Technology Data Exchange (ETDEWEB)

    Tesarova, E.; Pacakova, V.

    1983-05-01

    Gas (GC) and high-performance liquid chromatographic (HPLC) methods in the analysis of phenols are reviewed. Among the great number of phenolic compounds analyzed, alkylphenols, chlorophenols, dihydroxy-and trihydroxy-benzenes and biphenols are chiefly considered. The advantages and drawbacks of the methods are discussed. Relationships between the structural characteristics of phenols, the stationary phase structure, the mobile phase composition and the retention data are treated. Typical examples of the conditions for GC and HPLC analysis are summarized in tables. 276 references

  12. Emergence of a two-dimensional macrospin liquid in a highly frustrated three-dimensional quantum magnet

    Science.gov (United States)

    Sikkenk, Tycho S.; Coester, Kris; Buhrandt, Stefan; Fritz, Lars; Schmidt, Kai P.

    2017-02-01

    The classical Ising model on the frustrated three-dimensional (3D) swedenborgite lattice has disordered spin liquid ground states for all ratios of inter- and intraplanar couplings. Quantum fluctuations due to a transverse field give rise to several exotic phenomena. In the limit of weakly coupled kagome layers we find a 3D version of disorder by disorder degeneracy lifting. For large out-of-plane couplings one-dimensional macrospins are formed, which realize a disordered macrospin liquid phase on an emerging two-dimensional triangular lattice. We speculate about a possibly exotic version of quantum criticality that connects the polarized phase to the macrospin liquid.

  13. Non-equilibrium nature of two-dimensional isotropic and nematic coexistence in amyloid fibrils at liquid interfaces.

    Science.gov (United States)

    Jordens, Sophia; Isa, Lucio; Usov, Ivan; Mezzenga, Raffaele

    2013-01-01

    Two-dimensional alignment of shape-anisotropic colloids is ubiquitous in nature, ranging from interfacial virus assembly to amyloid plaque formation. The principles governing two-dimensional self-assembly have therefore long been studied, both theoretically and experimentally, leading, however, to diverging fundamental interpretations on the nature of the two-dimensional isotropic-nematic phase transition. Here we employ single-molecule atomic force microscopy, cryogenic scanning electron microscopy and passive probe particle tracking to study the adsorption and liquid crystalline ordering of semiflexible β-lactoglobulin fibrils at liquid interfaces. Fibrillar rigidity changes on increasing interfacial density, with a maximum caused by alignment and a subsequent decrease stemming from crowding and domain bending. Coexistence of nematic and isotropic regions is resolved and quantified by a length scale-dependent order parameter S(2D)(d). The nematic surface fraction increases with interfacial fibril density, but depends, for a fixed interfacial density, on the initial bulk concentration, ascribing the observed two-dimensional isotropic-nematic coexistence to non-equilibrium phenomena.

  14. Comprehensive characterization of Stevia rebaudiana using two-dimensional reversed-phase liquid chromatography/hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Fu, Qing; Guo, Zhimou; Zhang, Xiuli; Liu, Yanfang; Liang, Xinmiao

    2012-07-01

    Two-dimensional reversed-phase liquid chromatography/hydrophilic interaction liquid chromatography (2D-RPLC/HILIC) system was successfully applied for comprehensive characterization of steviol glycosides from Stevia rebaudiana. The experiments were performed in offline mode using an XCharge C18 column in first dimension and an XAmide column in second dimension. In first dimension, preliminary separation of Stevia aqueous extract was accomplished and 30 fractions were collected. Then fractions 1-20 were selected for further purification and 13 compounds with high purity were obtained in second dimension. Comprehensive characterization of these compounds was completed by determination of their retention time, accurate molecular weight, diagnostic fragmentation ions, and nuclear magnetic resonance spectroscopy. As a result, all nine known steviol glycosides, as well as other four steviol glycosides were fully purified. The result demonstrated that this procedure is an effective approach for the preparative separation and comprehensive characterization of steviol glycosides in Stevia. This 2D-RPLC/HILIC method will be a promising tool for the purification of low-abundance compounds from natural products.

  15. Comprehensive two-dimensional liquid chromatography: Ion chromatography × reversed-phase liquid chromatography for separation of low-molar-mass organic acids

    NARCIS (Netherlands)

    S.S. Brudin; R.A. Shellie; P.R. Haddad; P.J. Schoenmakers

    2010-01-01

    In the work presented here a novel approach to comprehensive two-dimensional liquid chromatography is evaluated. Ion chromatography is chosen for the first-dimension separation and reversed-phase liquid chromatography is chosen for the second-dimension separation mode. The coupling of these modes is

  16. New on-line separation workflow of microbial metabolites via hyphenation of analytical and preparative comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Yan, Xia; Wang, Li-Juan; Wu, Zhen; Wu, Yun-Long; Liu, Xiu-Xiu; Chang, Fang-Rong; Fang, Mei-Juan; Qiu, Ying-Kun

    2016-10-15

    Microbial metabolites represent an important source of bioactive natural products, but always exhibit diverse of chemical structures or complicated chemical composition with low active ingredients content. Traditional separation methods rely mainly on off-line combination of open-column chromatography and preparative high performance liquid chromatography (HPLC). However, the multi-step and prolonged separation procedure might lead to exposure to oxygen and structural transformation of metabolites. In the present work, a new two-dimensional separation workflow for fast isolation and analysis of microbial metabolites from Chaetomium globosum SNSHI-5, a cytotoxic fungus derived from extreme environment. The advantage of this analytical comprehensive two-dimensional liquid chromatography (2D-LC) lies on its ability to analyze the composition of the metabolites, and to optimize the separation conditions for the preparative 2D-LC. Furthermore, gram scale preparative 2D-LC separation of the crude fungus extract could be performed on a medium-pressure liquid chromatograph×preparative high-performance liquid chromatography system, under the optimized condition. Interestingly, 12 cytochalasan derivatives, including two new compounds named cytoglobosin Ab (3) and isochaetoglobosin Db (8), were successfully obtained with high purity in a short period of time. The structures of the isolated metabolites were comprehensively characterized by HR ESI-MS and NMR. To be highlighted, this is the first report on the combination of analytical and preparative 2D-LC for the separation of microbial metabolites. The new workflow exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods.

  17. Quasi-particle properties in a quasi-two-dimensional electron liquid

    Indian Academy of Sciences (India)

    R Asgari; B Tanatar

    2008-02-01

    We consider the quasi-particle properties such as the effective mass and spin susceptibility of quasi-two-dimensional electron systems. The finite quantum well width effects are incorporated into the local-field factors that describe the charge and spin correlations. We employ the Fermi-hypernetted chain formalism in conjunction with fluctuation-dissipation theorem to obtain the local-field factors. Our results are in good agreement with recent experiments.

  18. Determination of pyrazinamide in human by high performance liquid chromatography.

    Directory of Open Access Journals (Sweden)

    Revankar S

    1994-01-01

    Full Text Available A facile and sensitive high performance liquid chromatographic (HPLC technique has been developed for the determination pyrazinamide (PZA in human plasma. Nicotinamide(NIA is used as internal standard(IS. Plasma is deproteinized with 0.7 M perchloric acid; clear supernatant is neutralized with 1M NaOH and injected onto HPLC. The separation of pyrazinamide and the internal standard is carried out on a Supelco LC-18 (DB column with a basic mobile phase. Pyrazinoic acid, the major metabolite, other anti-tuberculous drugs and endogenous components do not interfere with measurement of pyrazinamide. The limit of detection of pyrazinamide with this method is 0.2 mg/0.2 ml plasma (CV 8.2%.

  19. [Determination of amygdalin in hawthorn by high performance liquid chromatography].

    Science.gov (United States)

    Lü, Weifeng; Ding, Mingyu

    2005-09-01

    A suitable method for extraction of amygdalin from hawthorn has been established. At first, the lipophilic components were removed with petroleum ether by ultrasonic extraction. The amygdalin was then extracted by methanol in a Soxhlet's apparatus. For quantitation, a high performance liquid chromatographic method was developed by using a reversed-phase C18 column, mobile phase of methanol-water (15:85, v/v) and a detection wavelengh of 215 nm. It can be concluded that the content of amygdalin is higher in the seeds than that in the hawthorn powder without the seeds and the yield of amygdalin is higher in the hawthorn pieces than that in the hawthorn powder.

  20. Quantum spin liquid and magnetic order in a two-dimensional nonsymmorphic lattice: Considering the distorted kagome lattice of volborthite

    Science.gov (United States)

    Chern, Li Ern; Hwang, Kyusung; Mizoguchi, Tomonari; Huh, Yejin; Kim, Yong Baek

    2017-07-01

    The Kagome-lattice-based material, volborthite, Cu3V2O7(OH) 2.2 H2O , has been considered as a promising platform for discovery of unusual quantum ground states due to the frustrated nature of spin interaction. We explore possible quantum spin liquid and magnetically ordered phases in a two-dimensional nonsymmorphic lattice, which is described by the plane group p 2 g g , consistent with the spatial anisotropy of the spin model derived from density functional theory (DFT) for volborthite. Using the projective symmetry group (PSG) analysis and Schwinger boson mean field theory, we classify possible spin liquid phases with bosonic spinons and investigate magnetically ordered phases connected to such states. It is shown, in general, that only translationally invariant mean field spin liquid ansatzes are allowed in two-dimensional nonsymmorphic lattices. We study the mean field phase diagram of the DFT-derived spin model and find that possible quantum spin liquid phases are connected to two types of magnetically ordered phases, a coplanar incommensurate (q ,0 ) spiral order as the ground state and a closely competing coplanar commensurate (π ,π ) spin density wave order. In addition, periodicity enhancement of the two-spinon continuum, a consequence of symmetry fractionalization, is found in the spin liquid state connected to the (π ,π ) spin density wave order. We discuss relevance of these results to recent and future experiments on volborthite.

  1. Two-dimensional spin liquids with Z2 topological order in an array of quantum wires

    Science.gov (United States)

    Patel, Aavishkar A.; Chowdhury, Debanjan

    2016-11-01

    Insulating Z2 spin liquids are a phase of matter with bulk anyonic quasiparticle excitations and ground-state degeneracies on manifolds with nontrivial topology. We construct a time-reversal symmetric Z2 spin liquid in two spatial dimensions using an array of quantum wires. We identify the anyons as kinks in the appropriate Luttinger-liquid description, compute their mutual statistics, and construct local operators that transport these quasiparticles. We also present a construction of a fractionalized Fermi liquid (FL*) by coupling the spin sector of the Z2 spin liquid to a Fermi liquid via a Kondo-like coupling.

  2. Unconventional High-Performance Laser Protection System Based on Dichroic Dye-Doped Cholesteric Liquid Crystals

    Science.gov (United States)

    Zhang, Wanshu; Zhang, Lanying; Liang, Xiao; Le Zhou; Xiao, Jiumei; Yu, Li; Li, Fasheng; Cao, Hui; Li, Kexuan; Yang, Zhou; Yang, Huai

    2017-01-01

    High-performance and cost-effective laser protection system is of crucial importance for the rapid advance of lasers in military and civilian fields leading to severe damages of human eyes and sensitive optical devices. However, it is crucially hindered by the angle-dependent protective effect and the complex preparation process. Here we demonstrate that angle-independence, good processibility, wavelength tunability, high optical density and good visibility can be effectuated simultaneously, by embedding dichroic anthraquinone dyes in a cholesteric liquid crystal matrix. More significantly, unconventional two-dimensional parabolic protection behavior is reported for the first time that in stark contrast to the existing protection systems, the overall parabolic protection behavior enables protective effect to increase with incident angles, hence providing omnibearing high-performance protection. The protective effect is controllable by dye concentration, LC cell thickness and CLC reflection efficiency, and the system can be made flexible enabling applications in flexible and even wearable protection devices. This research creates a promising avenue for the high-performance and cost-effective laser protection, and may foster the development of optical applications such as solar concentrators, car explosion-proof membrane, smart windows and polarizers. PMID:28230153

  3. Purification of flavonoids from licorice using an off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method.

    Science.gov (United States)

    Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu

    2016-07-01

    An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice.

  4. Analysis of Free Fatty Acids on the Fingertips by High Performance Liquid Chromatography.

    Science.gov (United States)

    1978-12-20

    This investigation studied the efficiency of high performance liquid chromatography in the determination of free fatty acids present on the...utilized to eliminate the microbial contamination. The high performance liquid chromatography provided excellent separation of skin fatty acids for

  5. Visualization of Structured Packing with Laser Induced Fluorescence Technique:Two-Dimensional Measurement of Liquid Concentration Distribution

    Institute of Scientific and Technical Information of China (English)

    刘伯潭; 申言同; 张会书; 刘春江; 唐忠利; 袁希钢

    2016-01-01

    A method of using laser induced fluorescence(LIF)technique was applied to two-dimensional meas-urement of the liquid concentration distribution in the 250Y structured packing sheet. The experimental structured packing sheet was made of perspex so that the laser could pass through it. The visualization of the distribution of the liquid concentration in the structured packing sheet was realized. The calibration of the thickness and liquid concentration was carried out firstly and the regression formulaI=kcd was acquired, in which concentrationc and the liquid film thicknessd were both considered. Then the liquid feed of uniform tracer(rhodamine)concentration entered the perspex structured packing from the top under different spraying densities. The corresponding thickness of liquid film on the packing was calculated. Finally, tracer(rhodamine)with a high concentration was injected only at one fixed point of the structured packing under different spraying densities of the liquid. With the known liquid film thickness, the concentration distribution of the tracer can be calculated inside the structured packing sheet.

  6. Viscosity of confined two-dimensional Yukawa liquids: A nonequilibrium method

    Energy Technology Data Exchange (ETDEWEB)

    Landmann, S. [Universität Leipzig, Institut für Theoretische Physik, Brüderstr. 16, 04103 Leipzig (Germany); Kählert, H.; Thomsen, H.; Bonitz, M. [Christian-Albrechts-Universität zu Kiel, Institut für Theoretische Physik und Astrophysik, Leibnizstr. 15, 24098 Kiel (Germany)

    2015-09-15

    We present a nonequilibrium method that allows one to determine the viscosity of two-dimensional dust clusters in an isotropic confinement. By applying a tangential external force to the outer parts of the cluster (e.g., with lasers), a sheared velocity profile is created. The decay of the angular velocity towards the center of the confinement potential is determined by a balance between internal (viscosity) and external friction (neutral gas damping). The viscosity can then be calculated from a fit of the measured velocity profile to a solution of the Navier-Stokes equation. Langevin dynamics simulations are used to demonstrate the feasibility of the method. We find good agreement of the measured viscosity with previous results for macroscopic Yukawa plasmas.

  7. Noncontact Cohesive Swimming of Bacteria in Two-Dimensional Liquid Films

    Science.gov (United States)

    Li, Ye; Zhai, He; Sanchez, Sandra; Kearns, Daniel B.; Wu, Yilin

    2017-07-01

    Bacterial swimming in confined two-dimensional environments is ubiquitous in nature and in clinical settings. Characterizing individual interactions between swimming bacteria in 2D confinement will help to understand diverse microbial processes, such as bacterial swarming and biofilm formation. Here we report a novel motion pattern displayed by flagellated bacteria in 2D confinement: When two nearby cells align their moving directions, they tend to engage in cohesive swimming without direct cell body contact, as a result of hydrodynamic interaction but not flagellar intertwining. We further found that cells in cohesive swimming move with higher directional persistence, which can increase the effective diffusivity of cells by ˜3 times as predicted by computational modeling. As a conserved behavior for peritrichously flagellated bacteria, cohesive swimming in 2D confinement may be key to collective motion and self-organization in bacterial swarms; it may also promote bacterial dispersal in unsaturated soils and in interstitial space during infections.

  8. Fermi liquid-to-Bose condensate crossover in a two-dimensional ultracold gas experiment

    Science.gov (United States)

    Barmashova, T. V.; Mart'yanov, K. A.; Makhalov, V. B.; Turlapov, A. V.

    2016-02-01

    By controling interparticle interactions, it is possible to transform a fermionic system into a bosonic system and vice versa, while preserving quantum degeneracy. Evidence of such a transformation may be found by monitoring the pressure and interference. The Fermi pressure is an indication of the fermion?ic character of a system, while the interference implies a nonzero order parameter and Bose condensation. Lowering from three to two spatial dimensions introduces new physics and makes the system more difficult to describe due to the increased fluctuations and the reduced applicability of mean field methods. An experiment with a two-dimensional ultracold atomic gas shows a crossover between the Bose and Fermi limits, as evident from the value of pressure and from the interference pattern, and provides data to test models of 2D Fermi and Bose systems, including the most-difficult-to-model strongly coupled systems.

  9. Determination of a Jet Fuel Metal Deactivator by High Performance Liquid Chromatography

    Science.gov (United States)

    1983-06-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Paul C. Hayes, Jr. Fuels Branch...SUPPLEMENTARY NOTES 19. KEY WORDS (Continue on reverse side if necessary and identify by block number) High Performance Liquid Chromatography absorbance...SYMBOL HPLC High Performance Liquid Chromatography P-4 jet propulsion fuel, wide-boiling range, conforming to MIL-T-5624L MDA metal deactivator,

  10. Determination of Stabiliser Contents in Advanced Gun Propellants by Reverse Phase High Performance Liquid Chromatography

    Science.gov (United States)

    1994-03-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY N"m A.R. TURNER AND A. WHITE...TO biEPROOU.; AND SELL THIS REPORT Determination of Stabiliser Contents in Advanced Gun Propellants by Reverse Phase High Performance Liquid Chromatography A.R...8217/......... .. Availability Cooes Dist Avaiardlo A-i Determination of Stabiliser Contents in Advanced Gun Propellants by Reverse Phase High Performance Liquid Chromatography

  11. Liquid-Gated High Mobility and Quantum Oscillation of the Two-Dimensional Electron Gas at an Oxide Interface.

    Science.gov (United States)

    Zeng, Shengwei; Lü, Weiming; Huang, Zhen; Liu, Zhiqi; Han, Kun; Gopinadhan, Kalon; Li, Changjian; Guo, Rui; Zhou, Wenxiong; Ma, Haijiao Harsan; Jian, Linke; Venkatesan, Thirumalai; Ariando

    2016-04-26

    Electric field effect in electronic double layer transistor (EDLT) configuration with ionic liquids as the dielectric materials is a powerful means of exploring various properties in different materials. Here, we demonstrate the modulation of electrical transport properties and extremely high mobility of two-dimensional electron gas at LaAlO3/SrTiO3 (LAO/STO) interface through ionic liquid-assisted electric field effect. With a change of the gate voltages, the depletion of charge carrier and the resultant enhancement of electron mobility up to 19 380 cm(2)/(V s) are realized, leading to quantum oscillations of the conductivity at the LAO/STO interface. The present results suggest that high-mobility oxide interfaces, which exhibit quantum phenomena, could be obtained by ionic liquid-assisted field effect.

  12. Determination of Finasteride in Tablets by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    K. Basavaiah

    2007-01-01

    Full Text Available A rapid, highly sensitive high performance liquid chromatographic method has been developed for the determination of finasteride(FNS in bulk drug and in tablets. FNS was eluted from a ODS C18 reversed phase column at laboratory temperature (30 ± 2°C with a mobile phase consisting of methanol and water (80+20 at a flow rate of 1 mL min-1 with UV detection at 225 nm. The retention time was ∼ 6.1 min and each analysis took not more than 10 min. Quantitation was achieved by measurement of peak area without using any internal standard. Calibration graph was linear from 2.0 to 30 μg mL-1 with limits of detection (LOD and quantification (LOQ being 0.2 and 0.6 μg mL-1, respectively. The method was validated according to the current ICH guidelines. Within-day co efficients of variation (CV ranged from 0.31 to 0.69% and between-day CV were in the range 1.2-3.2%. Recovery of FNS from the pharmaceutical dosage forms ranged from 97.89 – 102.9 with CV of 1.41-4.13%. The developed method was compared with the official method for FNS determination in its tablet forms.

  13. Determination of saffron quality by high-performance liquid chromatography.

    Science.gov (United States)

    Valle García-Rodríguez, M; Serrano-Díaz, Jéssica; Tarantilis, Petros A; López-Córcoles, Horacio; Carmona, Manuel; Alonso, Gonzalo L

    2014-08-13

    The aim of this work was to propose a high-performance liquid chromatography with diode array detection (HPLC-DAD) method for determining the three main compounds responsible for determining the quality of saffron (crocetin esters, picrocrocin, and safranal) by preparing an aqueous extract according to the ISO 3632 standard to solve the difficulty that this standard has for aroma and taste determination by ultraviolet-visible spectroscopy. Toward this aim, laboratory-isolated picrocrocin, a safranal standard with a purity of ≥ 88%, trans-crocetin di(β-D-gentiobiosyl) ester (trans-4-GG) and trans-crocetin (β-D-glucosyl)-(β-D-gentiobiosyl) ester (trans-3-Gg) standards, both with a purity of ≥ 99%, and 50 different saffron spice samples from Italy, Iran, Greece, and Spain were used in the intralaboratory validation of the HPLC method. The analytical method proposed was adequate in terms of linearity, selectivity, sensitivity, and accuracy for determining the three foremost parameters that define the quality of saffron using only a saffron solution prepared according to the ISO 3632 standard.

  14. Gradient chromatofocusing high-performance liquid chromatography. I. Practical aspects.

    Science.gov (United States)

    Liu, Y; Anderson, D J

    1997-02-21

    In this work, a versatile method for generating linear pH gradients using weak anion-exchange HPLC has been developed, which is termed gradient chromatofocusing high-performance liquid chromatography. This method utilizes a linear external pH gradient generated in the mobile phase entering the column (inlet pH gradient), superimposed on an internally-generated pH gradient within the column (column pH gradient), which results from the buffering action of the ion exchanger on the mobile phase and vice versa. The method shows significant advantages over conventional chromatofocusing, including: decreased expense due to the use of common buffer components, ease of adjusting the slope of the pH gradient produced at the outlet of the column (outlet pH gradient) through the manipulation of the inlet pH gradient and the ability of using high concentration buffers in the mobile phase. Chromatography of fibrinogen degradation products was done using gradient chromatofocusing. Bandwidths comparable to conventional chromatofocusing were obtained in the separation of fibrinogen degradation products.

  15. Gradient chromatofocusing high-performance liquid chromatography. II. Theoretical aspects.

    Science.gov (United States)

    Liu, Y; Anderson, D J

    1997-02-21

    This article is Part II of a series describing a newly-developed gradient chromatofocusing high-performance liquid chromatography (HPLC) technique. Theoretical aspects of the technique are discussed. In gradient chromatofocusing, the column pH gradient with respect to column distance can be varied without necessarily affecting the outlet pH gradient with respect to time. Factors influencing the value of the slope of the column pH gradient are identified through derived equations and a computer simulation model. A newly-identified parameter is introduced, column travel time, which can be uniquely varied in gradient chromatofocusing. Experiments show increased conversion of fibrinogen to denatured forms with increased column travel time. Another unique aspect of gradient chromatofocusing is that the mobile phase buffer concentration can be manipulated without necessarily affecting the outlet pH gradient slope, giving the technique expanded versatility for optimizing the separation. In the present work, the pIapparent for fibrinogen is found to increase with increased mobile phase buffer concentration.

  16. Two-dimensional liquid chromatography for direct chiral separations: a review.

    Science.gov (United States)

    León-González, María Eugenia; Rosales-Conrado, Noelia; Pérez-Arribas, Luis Vicente; Guillén-Casla, Vanesa

    2014-01-01

    Separation of enantiomers remains a challenge owing to their identical physical and chemical properties in an achiral environment, and research on specialized separation techniques such as multidimensional achiral-chiral liquid chromatography continues to resolve individual enantiomers in complex samples. Recent advances in application of multidimensional liquid chromatography applied to chiral analysis are reviewed. For this reason, benefits of achiral-chiral coupling are shown, with emphasis in applications on biological and pharmaceutical fields as well as pesticide analysis. A description of standard instrumental setup in both heart-cut and comprehensive multidimensional liquid chromatography is shown. The most broadly used chiral stationary phases for multidimensional liquid chromatography are summarized. An extensive overview of different interface designs applied to complex samples is presented.

  17. Bubble statistics and coarsening dynamics for quasi-two-dimensional foams with increasing liquid content.

    Science.gov (United States)

    Roth, A E; Jones, C D; Durian, D J

    2013-04-01

    We report on the statistics of bubble size, topology, and shape and on their role in the coarsening dynamics for foams consisting of bubbles compressed between two parallel plates. The design of the sample cell permits control of the liquid content, through a constant pressure condition set by the height of the foam above a liquid reservoir. We find that in the scaling regime, all bubble distributions are independent not only of time, but also of liquid content. For coarsening, the average rate decreases with liquid content due to the blocking of gas diffusion by Plateau borders inflated with liquid; we achieve a factor of 4 reduction from the dry limit. By observing the growth rate of individual bubbles, we find that von Neumann's law becomes progressively violated with increasing wetness and decreasing bubble size. We successfully model this behavior by explicitly incorporating the border-blocking effect into the von Neumann argument. Two dimensionless bubble shape parameters naturally arise, one of which is primarily responsible for the violation of von Neumann's law for foams that are not perfectly dry.

  18. One-step thermolysis synthesis of two-dimensional ultrafine Fe3O4 particles/carbon nanonetworks for high-performance lithium-ion batteries

    Science.gov (United States)

    Zhang, Wanqun; Li, Xiaona; Liang, Jianwen; Tang, Kaibin; Zhu, Yongchun; Qian, Yitai

    2016-02-01

    To tackle the issue of inferior cycle stability and rate capability for Fe3O4 anode materials in lithium ion batteries, ultrafine Fe3O4 nanocrystals uniformly encapsulated in two-dimensional (2D) carbon nanonetworks have been fabricated through thermolysis of a simple, low-cost iron(iii) acetylacetonate without any extra processes. Moreover, compared to the reported Fe3O4/carbon composites, the particle size of Fe3O4 is controllable and held down to ~3 nm. Benefitting from the synergistic effects of the excellent electroconductive carbon nanonetworks and uniform distribution of ultrafine Fe3O4 particles, the prepared 2D Fe3O4/carbon nanonetwork anode exhibits high reversible capacity, excellent rate capability and superior cyclability. A high capacity of 1534 mA h g-1 is achieved at a 1 C rate and is maintained without decay up to 500 cycles (1 C = 1 A g-1). Even at the high current density of 5 C and 10 C, the 2D Fe3O4/carbon nanonetworks maintain a reversible capacity of 845 and 647 mA h g-1 after 500 discharge/charge cycles, respectively. In comparison with other reported Fe3O4-based anodes, the 2D Fe3O4/carbon nanonetwork electrode is one of the most attractive of those in energy storage applications.To tackle the issue of inferior cycle stability and rate capability for Fe3O4 anode materials in lithium ion batteries, ultrafine Fe3O4 nanocrystals uniformly encapsulated in two-dimensional (2D) carbon nanonetworks have been fabricated through thermolysis of a simple, low-cost iron(iii) acetylacetonate without any extra processes. Moreover, compared to the reported Fe3O4/carbon composites, the particle size of Fe3O4 is controllable and held down to ~3 nm. Benefitting from the synergistic effects of the excellent electroconductive carbon nanonetworks and uniform distribution of ultrafine Fe3O4 particles, the prepared 2D Fe3O4/carbon nanonetwork anode exhibits high reversible capacity, excellent rate capability and superior cyclability. A high capacity of 1534 mA h

  19. Response of an anisotropic liquid-saturated porous medium due to two dimensional sources

    Indian Academy of Sciences (India)

    Rajneesh Kumar; Aseem Miglani; N R Garg

    2002-06-01

    Eigenvalue approach, following Laplace and Fourier transforms, has been employed to find the general solution to the field equations in an anisotropic liquid-saturated porous medium, in the transformed domain. The results of isotropic liquid-saturated porous medium can be derived as a special case. A numerical inversion technique has been applied to get the solutions in the physical domain. To illustrate the utility of the approach, an application of infinite space with impulsive force at the origin has been considered. The results in the form of displacement and stress components have been obtained and discussed graphically for a particular model.

  20. Two dimensional, electronic particle tracking in liquids with a graphene-based magnetic sensor array

    Science.gov (United States)

    Neumann, Rodrigo F.; Engel, Michael; Steiner, Mathias

    2016-07-01

    The investigation and control of liquid flow at the nanometer scale is a key area of applied research with high relevance to physics, chemistry, and biology. We introduce a method and a device that allows the spatial resolution of liquid flow by integrating an array of graphene-based magnetic (Hall) sensors that is used for tracking the movement of magnetic nanoparticles immersed in a liquid under investigation. With a novel device concept based on standard integration processes and experimentally verified material parameters, we numerically simulate the performance of a single sensor pixel, as well as the whole sensor array, for tracking magnetic nanoparticles having typical properties. The results demonstrate that the device enables (a) the detection of individual nanoparticles in the liquid with high accuracy and (b) the reconstruction of a particle's flow-driven trajectory across the integrated sensor array with sub-pixel precision as a function of time, in what we call the ``Magnetic nanoparticle velocimetry'' technique. Since the method does not rely on optical detection, potential lab-on-chip applications include particle tracking and flow analysis in opaque media at the sub-micron scale.The investigation and control of liquid flow at the nanometer scale is a key area of applied research with high relevance to physics, chemistry, and biology. We introduce a method and a device that allows the spatial resolution of liquid flow by integrating an array of graphene-based magnetic (Hall) sensors that is used for tracking the movement of magnetic nanoparticles immersed in a liquid under investigation. With a novel device concept based on standard integration processes and experimentally verified material parameters, we numerically simulate the performance of a single sensor pixel, as well as the whole sensor array, for tracking magnetic nanoparticles having typical properties. The results demonstrate that the device enables (a) the detection of individual

  1. Fast fringe-field switching of a liquid crystal cell by two-dimensional confinement with virtual walls

    Science.gov (United States)

    Choi, Tae-Hoon; Oh, Seung-Won; Park, Young-Jin; Choi, Yeongyu; Yoon, Tae-Hoon

    2016-06-01

    We report a simple method for reducing the response time of a fringe-field switching liquid crystal cell by using two-dimensional confinement of the liquid crystals. Through both numerical calculations and experiments, we show that the switching speed can be increased by several fold in a fringe-field switching cell by simply using a rubbing angle of zero, which causes virtual walls to be built when an electric field is applied between the interdigitated electrodes and the common electrode, without requiring additional fabrication steps or complicated drive schemes. Furthermore, the devices fabricated with this method exhibit a reduced color shift and excellent dynamic stability, even with a high applied voltage and under external pressure.

  2. Cascades and spectra of a turbulent spinodal decomposition in two-dimensional symmetric binary liquid mixtures

    Science.gov (United States)

    Fan, Xiang; Diamond, P. H.; Chacón, L.; Li, Hui

    2016-09-01

    We study the fundamental physics of cascades and spectra in two-dimensional (2D) Cahn-Hilliard-Navier-Stokes (CHNS) turbulence, and compare and contrast this system with 2D magnetohydrodynamic (MHD) turbulence. The important similarities include basic equations, ideal quadratic invariants, cascades, and the role of linear elastic waves. Surface tension induces elasticity, and the balance between surface tension energy and turbulent kinetic energy determines a length scale (Hinze scale) of the system. The Hinze scale may be thought of as the scale of emergent critical balance between fluid straining and elastic restoring forces. The scales between the Hinze scale and dissipation scale constitute the elastic range of the 2D CHNS system. By direct numerical simulation, we find that in the elastic range, the mean square concentration spectrum Hkψ of the 2D CHNS system exhibits the same power law (-7 /3 ) as the mean square magnetic potential spectrum HkA in the inverse cascade regime of 2D MHD. This power law is consistent with an inverse cascade of Hψ, which is observed. The kinetic energy spectrum of the 2D CHNS system is EkK˜k-3 if forced at large scale, suggestive of the direct enstrophy cascade power law of 2D Navier-Stokes turbulence. The difference from the energy spectra of 2D MHD turbulence implies that the back reaction of the concentration field to fluid motion is limited. We suggest this is because the surface tension back reaction is significant only in the interfacial regions. The interfacial regions fill only a small portion of the 2D CHNS system, and their interface packing fraction is much smaller than that for 2D MHD.

  3. Observation of a roton collective mode in a two-dimensional Fermi liquid.

    Science.gov (United States)

    Godfrin, Henri; Meschke, Matthias; Lauter, Hans-Jochen; Sultan, Ahmad; Böhm, Helga M; Krotscheck, Eckhard; Panholzer, Martin

    2012-03-28

    Understanding the dynamics of correlated many-body quantum systems is a challenge for modern physics. Owing to the simplicity of their Hamiltonians, (4)He (bosons) and (3)He (fermions) have served as model systems for strongly interacting quantum fluids, with substantial efforts devoted to their understanding. An important milestone was the direct observation of the collective phonon-roton mode in liquid (4)He by neutron scattering, verifying Landau's prediction and his fruitful concept of elementary excitations. In a Fermi system, collective density fluctuations (known as 'zero-sound' in (3)He, and 'plasmons' in charged systems) and incoherent particle-hole excitations are observed. At small wavevectors and energies, both types of excitation are described by Landau's theory of Fermi liquids. At higher wavevectors, the collective mode enters the particle-hole band, where it is strongly damped. The dynamics of Fermi liquids at high wavevectors was thus believed to be essentially incoherent. Here we report inelastic neutron scattering measurements of a monolayer of liquid (3)He, observing a roton-like excitation. We find that the collective density mode reappears as a well defined excitation at momentum transfers larger than twice the Fermi momentum. We thus observe unexpected collective behaviour of a Fermi many-body system in the regime beyond the scope of Landau's theory. A satisfactory interpretation of the measured spectra is obtained using a dynamic many-body theory.

  4. Two-dimensional optical correlation spectroscopy applied to liquid/glass dynamics

    NARCIS (Netherlands)

    Lazonder, Kees; Pshenichnikov, Maxim S.; Wiersma, Douwe A.; Corkum, Paul; Jonas, David M.; Miller, R.J. Dwayne.; Weiner, Andrew M.

    2007-01-01

    Correlation spectroscopy was used to study the effects of temperature and phase changes on liquid and glass solvent dynamics. By assessing the eccentricity of the elliptic shape of a 2D optical correlation spectrum the value of the underlying frequency-frequency correlation function can be retrieved

  5. Two-dimensional optical correlation spectroscopy applied to liquid/glass dynamics

    NARCIS (Netherlands)

    Lazonder, Kees; Pshenichnikov, Maxim S.; Wiersma, Douwe A.

    2006-01-01

    Correlation spectroscopy was used to study the effects of temperature and phase changes on liquid and glass solvent dynamics. This method yielded both intuitive clues and a quantitative measure of the dynamics of the system. © 2006 Optical Society of America.

  6. Two dimensional, electronic particle tracking in liquids with a graphene-based magnetic sensor array.

    Science.gov (United States)

    Neumann, Rodrigo F; Engel, Michael; Steiner, Mathias

    2016-07-14

    The investigation and control of liquid flow at the nanometer scale is a key area of applied research with high relevance to physics, chemistry, and biology. We introduce a method and a device that allows the spatial resolution of liquid flow by integrating an array of graphene-based magnetic (Hall) sensors that is used for tracking the movement of magnetic nanoparticles immersed in a liquid under investigation. With a novel device concept based on standard integration processes and experimentally verified material parameters, we numerically simulate the performance of a single sensor pixel, as well as the whole sensor array, for tracking magnetic nanoparticles having typical properties. The results demonstrate that the device enables (a) the detection of individual nanoparticles in the liquid with high accuracy and (b) the reconstruction of a particle's flow-driven trajectory across the integrated sensor array with sub-pixel precision as a function of time, in what we call the "Magnetic nanoparticle velocimetry" technique. Since the method does not rely on optical detection, potential lab-on-chip applications include particle tracking and flow analysis in opaque media at the sub-micron scale.

  7. Two-Dimensional FTIR as a Tool to Study the Chemical Interactions within Cellulose-Ionic Liquid Solutions

    Directory of Open Access Journals (Sweden)

    Kalyani Kathirgamanathan

    2015-01-01

    Full Text Available In this study two-dimensional FTIR analysis was applied to understand the temperature effects on processing cellulose solutions in imidazolium-based ionic liquids. Analysis of the imidazolium ion νC2–H peak revealed hydrogen bonding within cellulose solutions to be dynamic on heating and cooling. The extent of hydrogen bonding was stronger on heating, consistent with greater ion mobility at higher temperature when the ionic liquid network structure is broken. At ambient temperatures a blue shifted νC2–H peak was indicative of greater cation-anion interactions, consistent with the ionic liquid network structure. Both cellulose and water further impact the extent of hydrogen bonding in these solutions. The FTIR spectral changes appeared gradual with temperature and contrast shear induced rheology changes which were observed on heating above 70°C and cooling below 40°C. The influence of cellulose on solution viscosity was not distinguished on initial heating as the ionic liquid network structure dominates rheology behaviour. On cooling, the quantity of cellulose has a greater influence on solution rheology. Outcomes suggest processing cellulose in ionic liquids above 40°C and to reduce the impacts of cation-anion effects and enhance solubilisation, processing should be done at 70°C.

  8. Two-Dimensional Metrology with Flatbed Scanners at Room and Liquid Nitrogen Temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A. [CIEMAT. Madrid (Spain)

    2000-07-01

    We study the capability of the commercial flatbed scanner as a measuring instrument of two-coordinate sample both at room and liquid nitrogen temperatures. We describes simple procedure to calibrate the scanner, and the most adequate standard configuration to carry out the measurements. To illustrate the procedure, we measure the relative positions of the conductors in a cross-section of a superconducting magnet of CERN. (Author) 8 refs.

  9. High Speed Photographic Studies Of Liquid/Solid Impact And Cavity Collapse Using Two-Dimensional Gelatine Configurations

    Science.gov (United States)

    Dear, J. P.; Field, J. E.; Swallowe, G. M.

    1985-02-01

    The techniques described in this paper were developed during a study of high velocity liquid/solid impact. This form of impact is relevant to a number of technological problems such as the rain erosion of aircraft, the erosion of steam turbine blades, cavitation damage and the cleaning, cutting or fragmentation of materials using high velocity liquid jets. There are advantages in creating two-dimensional impact geometries since these enable processes occurring inside the impacted liquid mass and the onset of jetting to be studied in detail. Liquid wedge and drop geometries are produced by first casting water/gelatine sheets and then cutting out the required shapes. The impacting solid is a plate fired from a rectangular bore gas gun. The impact is viewed at high magnification using high speed photography at microsecond framing rates with an Imacon camera, and the shocks are visulised using Schlieren photography. The results give information on the shock structures produced, the "water hammer" and "edge" pressures and the critical conditions for jetting. The two-dimensional techniques have also been applied to studies of cavity collapse. In this case, a single cavity, or an array of cavities, is formed in the gelatine layer. An advantage of the technique is that the cavity size and spacing can be accurately controlled. It is well known that when a shock passes over a cavity, a jet is formed in the direction of the shock, by involution of the cavity surface. The impact of this jet onto a solid surface is an important feature of cavitation damage. In our experiments, we have also studied shocks passing over an array of cavities. Cavity collapse is also important as an ignition mechanism with explosives and as a source of "hot-spots" which aid the build-up to, and propagation of, fast reaction in explosives. However, there is still controversy about the relative importance of adiabatic heating of the gas in the cavity and shock heating when the jet impacts the far side

  10. The use of online heart-cutting high-performance liquid chromatography coupled with linear ion trap mass spectrometry in the identification of impurities in vidarabine monophosphate.

    Science.gov (United States)

    Wang, Hang; Xu, Tongzhou; Yuan, Jiaojian

    2017-02-17

    It is difficult to identify unknown impurities in nucleotide analogues by mass spectrometry because mass-spectrometry-incompatible mobile phases need to be used to separate the major ingredient from impurities. In this study, vidarabine monophosphate was selected, and unknown impurities were identified by online heart-cutting two-dimensional high-performance liquid chromatography and linear ion trap mass spectrometry. The one-dimensional reversed-phase column was filled with a mobile phase containing nonvolatile salt. In two-dimensional high-performance liquid chromatography, we used an Acclaim Q1 column with volatile salt, and the detection wavelength was 260 nm. The mass spectrum was scanned in positive- and negative-ion mode. The online heart-cutting and online demineralization technique ensured that the mobile phase was compatible with mass spectrometry; seven impurities were identified by MS(2) and MS(3) fragments. The mass fragmentation patterns of these impurities were investigated. The two isomers were semiprepared and complemented by nuclear magnetic resonance. The results were further compared with those of normal-phase high-performance liquid chromatography with mass spectrometry. The online heart-cutting two-dimensional high-performance liquid chromatography with mass spectrometry was superior in identifying more impurities. The method solves the problem of incompatibility between the mobile phase and mass spectrometry, so it is suitable for identifying unknown impurities. This method may also be used for investigating impurities in other nucleotide analogues.

  11. Exploring Two-Dimensional Transport Phenomena in Metal Oxide Heterointerfaces for Next-Generation, High-Performance, Thin-Film Transistor Technologies.

    Science.gov (United States)

    Labram, John G; Lin, Yen-Hung; Anthopoulos, Thomas D

    2015-11-04

    In the last decade, metal oxides have emerged as a fascinating class of electronic material, exhibiting a wide range of unique and technologically relevant characteristics. For example, thin-film transistors formed from amorphous or polycrystalline metal oxide semiconductors offer the promise of low-cost, large-area, and flexible electronics, exhibiting performances comparable to or in excess of incumbent silicon-based technologies. Atomically flat interfaces between otherwise insulating or semiconducting complex oxides, are also found to be highly conducting, displaying 2-dimensional (2D) charge transport properties, strong correlations, and even superconductivity. Field-effect devices employing such carefully engineered interfaces are hoped to one day compete with traditional group IV or III-V semiconductors for use in the next-generation of high-performance electronics. In this Concept article we provide an overview of the different metal oxide transistor technologies and potential future research directions. In particular, we look at the recent reports of multilayer oxide thin-film transistors and the possibility of 2D electron transport in these disordered/polycrystalline systems and discuss the potential of the technology for applications in large-area electronics.

  12. High Performance Liquid Chromatography Experiments to Undergraduate Laboratories

    Science.gov (United States)

    Kissinger, Peter T.; And Others

    1977-01-01

    Reviews the principles of liquid chromatography with electrochemical detection (LCEC), an analytical technique that incorporates the advantages of both liquids chromatography and electrochemistry. Also suggests laboratory experiments using this technique. (MLH)

  13. d-wave superconductivity, antiferromagnetism and spin liquid in quasi-two-dimensional organic superconductors

    Directory of Open Access Journals (Sweden)

    P. Sahebsara

    2006-09-01

    Full Text Available   The self-energy-functional approach is a powerful many-body tool to investigate different broken symmetry phases of strongly correlated electron systems. We use the variational cluster perturbation theory (also called the variational cluster approximation to investigate the interplay between the antiferromagnetism and d-wave superconductivity of κ-(ET2 X conductors. These compounds are described by the so-called dimer Hubbard model, with various values of the on-site repulsion U and diagonal hopping amplitude t. At strong coupling, our zero-temperature calculations show a transition from Néel antiferromagnetism to a spin-liquid phase with no long range order, at around t ~ 0.9. At lower values of U, we find d-wave superconductivity. Taking into account the point group symmetries of the lattice, we find a transition between dx2-y2 and dxy pairing symmetries, the latter happening for smaller values of U.

  14. Two-Dimensional Wave Motion on the Charged Surface of a Viscous Liquid

    Institute of Scientific and Technical Information of China (English)

    LI Fang; YIN Xie-Yuan; YIN Xie-Zhen

    2008-01-01

    The wave motion on the charged surface of a viscous Newtonian liquid is solved as an initial-value problem. Both the leaky dielectric and perfect dielectric cases are considered. The amplitude of wave is assumed to be small. The electric field induced by surface charge is shown to have a generally destabilizing effect on surface wave. The neutral stability curve is drawn in the (G, N,e) plane (G: the gravitational bond number; Ne: the electrical Bond number). The Ohnesorge number, Taylor-Melcher number and permittivity ratio have little influence on the neutral stability curve. It is testified that the classical normal mode method cannot predict wave behaviour at small times.

  15. Using the hydrophobic subtraction model to choose orthogonal columns for online comprehensive two-dimensional liquid chromatography

    DEFF Research Database (Denmark)

    Græsbøll, Rune; Nielsen, Nikoline Juul; Christensen, Jan H.

    2014-01-01

    A method for choosing orthogonal columns for a specific sample set in on-line comprehensive two-dimensional liquid chromatography (LC×LC) was developed on the basis of the hydrophobic subtraction model. The method takes into account the properties of the sample analytes by estimating new F...... by Gilroy et al. [1], (3) F-weights determined from the retention of sample analytes but using principal component analysis (PCA) for the estimation, and (4) the Gilroy F-weights modified by excluding the C-term in the hydrophobic subtraction model, as suggested by Dolan and Snyder [2]. The retention of 13...... neutral and 4 acidic oxygenated polycyclic aromatic compounds (PACs) and 3 nitrogen-containing PAC bases was measured isocratically on 12 columns. The isocratic runs were used to determine the hydrophobic subtraction model analyte parameters, and these were used to estimate new F-weights and predict...

  16. Unstable shear flows in two dimensional strongly correlated liquids - a hydrodynamic and molecular dynamics study

    Science.gov (United States)

    Gupta, Akanksha; Ganesh, Rajaraman; Joy, Ashwin

    2016-11-01

    In Navier-Stokes fluids, shear flows are known to become unstable leading to instability and eventually to turbulence. A class of flow namely, Kolmogorov Flows (K-Flows) exhibit such transition at low Reynolds number. Using fluid and molecular dynamics, we address the physics of transition from laminar to turbulent regime in strongly correlated-liquids such as in multi-species plasmas and also in naturally occurring plasmas with K-Flows as initial condition. A 2D phenomenological generalized hydrodynamic model is invoked wherein the effect of strong correlations is incorporated via a viscoelastic memory. To study the stability of K-Flows or in general any shear flow, a generalized eigenvalue solver has been developed along with a spectral solver for the full nonlinear set of fluid equations. A study of the linear and nonlinear features of K-Flow in incompressible and compressible limit exhibits cyclicity and nonlinear pattern formation in vorticity. A first principles based molecular dynamics simulation of particles interacting via Yukawa potential is performed with features such as configurational and kinetic thermostats for K-Flows. This work reveals several interesting similarities and differences between hydrodynamics and molecular dynamics studies.

  17. A novel two-dimensional liquid chromatographic system for the online toxicity prediction of pharmaceuticals and related substances

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jian; Xu, Li [Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan 430030 (China); Shi, Zhi-guo, E-mail: shizg@whu.edu.cn [Department of Chemistry, Wuhan University, Wuhan 430072 (China); Hu, Min [Hubei Instrument for Food and Drug Control, Wuhan (China)

    2015-08-15

    Highlights: • A novel two-dimensional liquid chromatographic system was developed. • The 1st dimension was ODS to separate components in the sample. • The 2nd dimension was biopartitioning micellar chromatography to predict toxicity. • The system was used to screen toxicity of pharmaceuticals and related substances. • It was promising for fast online toxicity screening of complex sample in one step. - Abstract: In this study, a novel two-dimensional liquid chromatographic (2D-LC) system was developed for simultaneous separation and toxicity prediction of pharmaceutical and its related substances. A conventional ODS column was used on the 1st-D to separate the sample; while, bio-partitioning micellar chromatography served as the 2nd-D to predict toxicity of the components. The established system was tested for the toxicity of ibuprofen and its impurities with known toxicity. With only one injection, ibuprofen and its impurities were separated on the 1st-D; and LC50 values of individual impurity were obtained based on the quantitative retention–activity relationships, which agreed well with the reported data. Furthermore, LC50 values of photolysis transformation products (TPs) of carprofen, ketoprofen and diclofenac acid (as unknown compounds) were screened in this 2D-LC system, which could be an indicator of the toxicity of these TPs and was meaningful for the environmental monitoring and drinking water treatment. The established 2D-LC system was cost-effective, time-saving and reliable, and was promising for fast online screening of toxicity of known and unknown analytes in the complex sample in a single step. It may find applications in environment, pharmaceutical and food, etc.

  18. Determination of Selected Colored Smokes on Glass Fiber Discs by High Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    1991-05-01

    High Performance Liquid Chromatography (HPLC) 12. PERSONAL AUTHOR(S) F F_ n.ipl’prifl. Alan R...GROUP SUB-GROUP High Performance Liquid Chromatography (HPLC), Analytical IMethod, 1,4-diamino-2,3-dihydroanthraquinone, 2-(2 - _ quinolinyl)-1,3...weights, low vapor pressures and low thermal stability. High performance liquid chromatography (HPLC) appears to be the analytical method of choice

  19. Two-dimensional preparative liquid chromatography system for preparative separation of minor amount components from complicated natural products

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, Ying-Kun, E-mail: qyk@xmu.edu.cn; Chen, Fang-Fang; Zhang, Ling-Ling; Yan, Xia; Chen, Lin; Fang, Mei-Juan; Wu, Zhen, E-mail: wuzhen@xmu.edu.cn

    2014-04-01

    Highlights: • Preparative MDLC system was developed for separation of complicated natural products. • Medium-pressure LC and preparative HPLC were connected by interface of SPE. • Automated multi-step preparative separation of 25 compounds was achieved by using this system. - Abstract: An on-line comprehensive two-dimensional preparative liquid chromatography system was developed for preparative separation of minor amount components from complicated natural products. Medium-pressure liquid chromatograph (MPLC) was applied as the first dimension and preparative HPLC as the second one, in conjunction with trapping column and makeup pump. The performance of the trapping column was evaluated, in terms of column size, dilution ratio and diameter-height ratio, as well as system pressure from the view of medium pressure liquid chromatograph. Satisfactory trapping efficiency can be achieved using a commercially available 15 mm × 30 mm i.d. ODS pre-column. The instrument operation and the performance of this MPLC × preparative HPLC system were illustrated by gram-scale isolation of crude macro-porous resin enriched water extract of Rheum hotaoense. Automated multi-step preparative separation of 25 compounds, whose structures were identified by MS, {sup 1}H NMR and even by less-sensitive {sup 13}C NMR, could be achieved in a short period of time using this system, exhibiting great advantages in analytical efficiency and sample treatment capacity compared with conventional methods.

  20. Sequence-dpenedent DNA separation by anion-exchange high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Yamakawa, Hisashi; Higashino, Ken-ich; Ohara, Osamu [Kazusa DNA Research Inst., Chiba (Japan)

    1996-09-05

    High-performance liquid chromatography (HPLC) system with a new nonporous anion-exchange resin, DNA-NPR, made it possible to rapidly separate DNA fragments up to 20 kbp with high resolution. In order to further characterize this chromatographic DNA separation system, we prepared a mixtures of double-stranded DNAs of constant length carrying a fully degenerated 50-bp region and analyzed their chromatographic behavior on the DNA-NPR column. The results indicated that the separation of DNA fragments on the anion-exchange HPLC was governed not only by size, but also by nucleotide sequence: even DNA fragments with the same size and the same base content could be separated on this column. Taking advantage of this characteristic feature of the anion-exchange HPLC, we could readily fractionate human cDNAs with practically acceptable recovery and high resolution. Furthermore, the combination of HPLC and gel electrophoresis realized separation of a mixture of DNA fragments in a two-dimensional pattern. 22 refs., 5 figs., 1 tab.

  1. High Performance Liquid Chromatography of Vitamin A: A Quantitative Determination.

    Science.gov (United States)

    Bohman, Ove; And Others

    1982-01-01

    Experimental procedures are provided for the quantitative determination of Vitamin A (retinol) in food products by analytical liquid chromatography. Standard addition and calibration curve extraction methods are outlined. (SK)

  2. Phase diagram of a two-dimensional liquid in GaAs/AlxGa1-xAs biased double quantum wells

    DEFF Research Database (Denmark)

    Timofeev, V. B.; Larionov, A. V.; Alessi, M. G.;

    2000-01-01

    densities, P, and temperatures, T. For increasing P or decreasing T, a sharp transition from two gases of photoexcited electrons and holes, spatially separated and confined in the two wells, to two two-dimensional (2D) liquids has been observed. The gas-to-2D-liquid transition is evidenced by a strong...

  3. Comprehensive two-dimensional liquid chromatography with on-line Fourier-transform-infrared-spectroscopy detection for the characterization of copolymers

    NARCIS (Netherlands)

    Kok, S.J.; Hankemeier, T.; Schoenmakers, P.J.

    2005-01-01

    The on-line coupling of comprehensive two-dimensional liquid chromatography (liquid chromatography × size-exclusion chromatography, LC × SEC) and infrared (IR) spectroscopy has been realized by means of an IR flow cell. The system has been assessed by the functional-group analysis of a series of

  4. Comprehensive two-dimensional liquid chromatography with on-line Fourier-transform-infrared-spectroscopy detection for the characterization of copolymers

    NARCIS (Netherlands)

    Kok, S.J.; Hankemeier, T.; Schoenmakers, P.J.

    2005-01-01

    The on-line coupling of comprehensive two-dimensional liquid chromatography (liquid chromatography × size-exclusion chromatography, LC × SEC) and infrared (IR) spectroscopy has been realized by means of an IR flow cell. The system has been assessed by the functional-group analysis of a series of sty

  5. Sheath liquid effects in capillary high-performance liquid chromatography-electrospray mass spectrometry of oligonucleotides.

    Science.gov (United States)

    Huber, C G; Krajete, A

    2000-02-18

    Fused-silica capillary columns of 200 microm inner diameter were packed with micropellicular, octadecylated, 2.3 microm poly(styrene-divinylbenzene) particles and applied to the separation of oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Oligonucleotides were eluted at 50 degrees C with gradients of 3-13% acetonitrile in 50 mM triethylammonium bicarbonate. Addition of sheath liquid to the column effluent allowed the detection of oligonucleotides by electrospray ionization mass spectrometry using full-scan data acquisition with a detectability comparable to that obtained with UV detection. The signal-to-noise ratios with different sheath liquids increased in the order isopropanolliquid was found to influence the charge state distribution of oligonucleotides longer than 20 nucleotide units whereas no significant effect was observed with shorter oligonucleotides. Organic acids and bases in the sheath liquid generally deteriorated the signal-to-noise ratios in the chromatograms and mass spectra mainly because of increased background noise. Only a few charge states were observed in the mass spectra of oligonucleotides because of charge state reduction due to the presence of carbonic acid in the eluent. With triethylammonium hydrogencarbonate as chromatographic eluent and acetonitrile as sheath liquid, very few cation adducts of oligonucleotides were observed in the mass spectra. However, the presence of small amounts of monopotassium adducts enabled the calculation of the charge state of multiply charged ions. With acetonitrile as sheath liquid, 710 amol of a 16-mer oligonucleotide were detected using selected ion monitoring data acquisition with a signal-to-noise ratio of 3:1. Finally, capillary ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry was

  6. Purification of amide alkaloids from Piper longum L. using preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography.

    Science.gov (United States)

    Li, Kuiyong; Zhu, Wenya; Fu, Qing; Ke, Yanxiong; Jin, Yu; Liang, Xinmiao

    2013-06-07

    A comprehensive off-line two-dimensional liquid chromatography (2D-LC) method coupling normal phase liquid chromatography (NPLC) and reversed phase liquid chromatography (RPLC) was developed for separation and purification of amide alkaloids from Piper longum L. In the first dimension, the crude alkaloid fractions were separated in NPLC mode and 20 fractions were collected. Then fractions 5-20 were selected for further purification in RPLC mode in the second dimension. The purities of RPLC fractions with similar structures were all identified accurately by ultra performance liquid chromatography (UPLC). In total, 28 compounds with high purity were obtained and their structures were comprehensively characterized by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR) spectroscopy. The results demonstrate that this 2D NPLC × RPLC method with good orthogonality (58.3%) was effective for the preparative separation and purification of amide alkaloids from Piper longum L.

  7. High-performance liquid chromatography with packed microchips

    OpenAIRE

    Ehlert, Steffen

    2011-01-01

    This work is explaining the importance of generating a densely packed chromatographic bed to achieve optimum separation efficiency in miniaturized liquid chromatography. The reduction of peak dispersion and enhancement of separation efficiency is the important problem in micro- and nano-separation that is to be solved to generate highly efficient chromatographic systems that can exploit all advantages of miniaturization. Therefore...

  8. High performance ultracapacitors with carbon nanomaterials and ionic liquids

    Science.gov (United States)

    Lu, Wen; Henry, Kent Douglas

    2012-10-09

    The present invention is directed to the use of carbon nanotubes and/or electrolyte structures in various electrochemical devices, such as ultracapacitors having an ionic liquid electrolyte. The carbon nanotubes are preferably aligned carbon nanotubes. Compared to randomly entangled carbon nanotubes, aligned carbon nanotubes can have better defined pore structures and higher specific surface areas.

  9. High performance batteries with carbon nanomaterials and ionic liquids

    Science.gov (United States)

    Lu, Wen

    2012-08-07

    The present invention is directed to lithium-ion batteries in general and more particularly to lithium-ion batteries based on aligned graphene ribbon anodes, V.sub.2O.sub.5 graphene ribbon composite cathodes, and ionic liquid electrolytes. The lithium-ion batteries have excellent performance metrics of cell voltages, energy densities, and power densities.

  10. High Performance Negative Dielectric Anisotropy Liquid Crystals for Display Applications

    Directory of Open Access Journals (Sweden)

    Xiaolong Song

    2013-09-01

    Full Text Available We review recent progress in the development of high birefringence (Δn ≥ 0.12 negative dielectric anisotropy (Δε < 0 liquid crystals (LCs for direct-view and projection displays. For mobile displays, our UCF-N2 (low viscosity, negative Δε, high Δn based homogeneous alignment fringe-field switching (called n-FFS mode exhibits superior performance to p-FFS in transmittance, single gamma curve, cell gap insensitivity, and negligible flexoelectric effect. For projection displays using a vertical alignment liquid-crystal-on-silicon (VA LCOS, our high birefringence UCF-N3 mixture enables a submillisecond gray-to-gray response time, which is essential for color sequential displays without noticeable color breakup. Our low viscosity UCF-N2 also enables multi-domain VA displays to use a thinner cell gap for achieving faster response time.

  11. High Performance Mars Liquid Cooling and Ventilation Garment Project

    Science.gov (United States)

    Terrier, Douglas; Clayton, Ronald; Whitlock, David; Conger, Bruce

    2015-01-01

    EVA space suit mobility in micro-gravity is enough of a challenge and in the gravity of Mars, improvements in mobility will enable the suited crew member to efficiently complete EVA objectives. The idea proposed is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area in order to free up the arms and legs by removing the liquid tubes currently used in the ISS EVA suit in the limbs. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased to provide the entire liquid cooling requirement and increase mobility by freeing up the arms and legs. Additional potential benefits of this approach include reduced LCVG mass, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development.

  12. Rapid analysis of phentolamine by high-performance liquid chromatography.

    Science.gov (United States)

    Webster, Gregory K; Lemmer, Robert R; Greenwald, Steven

    2003-02-01

    A rapid liquid chromatographic method is validated for the quantitative analysis of phentolamine. Phentolamine exists in three forms for this investigation: as a mesylate salt, hydrochloride salt, and free base. In solution, phentolamine dissociates from its salt and is chromatographed as free phentolamine. This validation confirms the analysis of each form, which is simply based upon molar mass differences encountered in weighing. As such, both the United States Pharmacopeia hydrochloride and mesylate standards are used throughout this validation to demonstrate this equivalency. The validation demonstrates that this method may be used to quantitate phentolamine, regardless of its salt form.

  13. On-line parallel reversed phase two-dimensional liquid chromatography for high-throughput analysis of complex proteomic samples

    Institute of Scientific and Technical Information of China (English)

    WANG Zhicong; ZHANG Qinghe; LI Tong; ZHAO Zhongyi; ZHANG Weibing

    2006-01-01

    A comprehensive two-dimensional liquid chromatographic system (2D SCX/RP) is constructed with a 10-port-2-way valve using strong cation exchange chromatography (Hypersil SCX, 100 mm×4.6 mm I.D.) followed by reversed phase chromatography (Hypersil BDS C18, 15 mm×4.6 mm I.D.) to separate the complex peptides from globin peptic hydrolysate. After the sample was loaded on the SCX column, the phosphate buffer (pH 4.0) was used to elute the peptides. Then, elutes flowed through the interface and the peptides focused on the head of the trapping columns (Hypersil BDS C18, 15 mm×4.6 mm I.D.) but salt passed into the waste. After the valve was switched, the samples were flushed with a backward flow into the RP analytical column. The peptides on the SCX were eluted with 12 discontinuous steps linearly increasing salt concentrations. The peptides enriched on the trapping column were desalted and separated by the RP columns. The resolution and the resolved peaks of the 2D SCX/RP system were greatly increased and the total peak capacity reached as high as 2280.

  14. Lipidic ionic liquid stationary phases for the separation of aliphatic hydrocarbons by comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Nan, He; Zhang, Cheng; O'Brien, Richard A; Benchea, Adela; Davis, James H; Anderson, Jared L

    2017-01-20

    Lipidic ionic liquids (ILs) possessing long alkyl chains as well as low melting points have the potential to provide unique selectivity as well as wide operating ranges when used as stationary phases in gas chromatography. In this study, a total of eleven lipidic ILs containing various structural features (i.e., double bonds, linear thioether chains, and cyclopropanyl groups) were examined as stationary phases in comprehensive two dimensional gas chromatography (GC×GC) for the separation of nonpolar analytes in kerosene. N-alkyl-N'-methyl-imidazolium-based ILs containing different alkyl side chains were used as model structures to investigate the effects of alkyl moieties with different structural features on the selectivities and operating temperature ranges of the IL-based stationary phases. Compared to a homologous series of ILs containing saturated side chains, lipidic ILs exhibit improved selectivity toward the aliphatic hydrocarbons in kerosene. The palmitoleyl IL provided the highest selectivity compared to all other lipidic ILs as well as the commercial SUPELCOWAX 10 column. The linoleyl IL containing two double bonds within the alkyl side chain showed the lowest chromatographic selectivity. The lipidic IL possessing a cyclopropanyl group within the alkyl moiety exhibited the highest thermal stability. The Abraham solvation parameter model was used to evaluate the solvation properties of the lipidic ILs. This study provides the first comprehensive examination into the relation between lipidic IL structure and the resulting solvation characteristics. Furthermore, these results establish a basis for applying lipidic ILs as stationary phases for solute specific separations in GC×GC.

  15. Two-dimensional liquid chromatography analysis of synthetic polymers using fast size exclusion chromatography at high column temperature.

    Science.gov (United States)

    Im, Kyuhyun; Park, Hae-Woong; Lee, Sekyung; Chang, Taihyun

    2009-05-22

    In recent years, two-dimensional liquid chromatography (2D-LC) has been used increasingly for the analysis of synthetic polymers. A 2D-LC analysis provides richer information than a single chromatography analysis at the cost of longer analysis time. The time required for a comprehensive 2D-LC analysis is essentially proportional to the analysis time of the second dimension separation. Many of 2D-LC analyses of synthetic polymers have employed size exclusion chromatography (SEC) for the second-dimension analysis due to the relatively short analysis time in addition to the wide use in the polymer analysis. Nonetheless, short SEC columns are often used for 2D-LC analyses to reduce the separation time, which inevitably deteriorates the resolution. In this study, we demonstrated that high temperature SEC can be employed as an efficient second-LC in the 2D-LC separation of synthetic polymers. By virtue of high temperature operation (low solvent viscosity and high diffusivity of the polymer molecules), a normal length SEC column can be used at high flow rate with little loss in resolution.

  16. Simultaneous achiral-chiral analysis of pharmaceutical compounds using two-dimensional reversed phase liquid chromatography-supercritical fluid chromatography.

    Science.gov (United States)

    Venkatramani, C J; Al-Sayah, Mohammad; Li, Guannan; Goel, Meenakshi; Girotti, James; Zang, Lisa; Wigman, Larry; Yehl, Peter; Chetwyn, Nik

    2016-02-01

    A new interface was designed to enable the coupling of reversed phase liquid chromatography (RPLC) and supercritical fluid chromatography (SFC). This online two-dimensional chromatographic system utilizing RPLC in the first dimension and SFC in the second was developed to achieve simultaneous achiral and chiral analysis of pharmaceutical compounds. The interface consists of an eight-port, dual-position switching valve with small volume C-18 trapping columns. The peaks of interest eluting from the first RPLC dimension column were effectively focused as sharp concentration pulses on small volume C-18 trapping column/s and then injected onto the second dimension SFC column. The first dimension RPLC separation provides the achiral purity result, and the second dimension SFC separation provides the chiral purity result (enantiomeric excess). The results are quantitative enabling simultaneous achiral, chiral analysis of compounds. The interface design and proof of concept demonstration are presented. Additionally, comparative studies to conventional SFC and case studies of the applications of 2D LC-SFC in pharmaceutical analysis is presented.

  17. Ambient temperature nanoelectrospray ion mobility detector for high performance liquid chromatography in determining amines.

    Science.gov (United States)

    Chen, Chuang; Hou, Keyong; Wang, Weiguo; Li, Jinghua; Li, Haiyang

    2014-09-01

    A nanoelectrospray ionization ion mobility spectrometer (nanoESI-IMS) working at ambient pressure and ambient temperature was developed as a detector of high performance liquid chromatography (HPLC) to achieve sensitive detection of amines with no derivatization and meanwhile provide another dimension of separation. The easier desolvation property of the charged droplets formed in nanoESI source enabled complete desolvation of the product ions of sixteen amines and drugs using the nanoESI-IMS at ambient temperature. Working at ambient temperature was good for suppressing the dissociation of thermal volatile ions, such as only the proton adducted molecular ions were observed for morphine in the nanoESI-IMS. Besides, the resolving power of the nanoESI-IMS also showed an increasing tendency as lowering the working temperature, an increment of 19 percent and 10 percent was observed for diethylamine and triethylamine as the temperature dropped from 92°C to 32°C. The resolving power of the nanoESI-IMS at 32°C for the 16 tested compounds was amid 33-44. With the nanoESI-IMS coupled to HPLC, a six-compound mixture including isomers was successfully separated and detected without any derivatization. And linear response ranges of 1 to 20, 0.5 to 20, and 0.8 to 20μgml(-1) and limits of detection of 0.25, 0.15, and 0.17μgml(-1) for triethylamine, diethylamine, and butylamine, respectively, were obtained with the hyphenated system. These results showed the excellent performance of the two-dimensional separation and detection method in direct qualitative and quantitative analyses of amines.

  18. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY DETECTORS – A REVIEW

    Directory of Open Access Journals (Sweden)

    Kaushal Ramni

    2011-05-01

    Full Text Available HPLC is the most versatile and widely used elution chromatography. The technique is used to resolve and determine species in a variety of organic, inorganic, biological, ionic and polymeric materials. Detector is the heart of an instrument and efficiency of system is dependent upon detecting techniques. Many types of HPLC detectors exist, each of which has some valuable performance feature such as refractive index detector, ultraviolet detector, fluorescent detector, electrochemical detector, electric conductivity detector, liquid light scattering detector, evaporative light scattering detector. Due to strong requirement for improvements in sensitivity, selectivity and other performance characteristics of the detector recent developments in conventional techniques and some other new technologies have been adopted such as laser light scattering detector, charged aerosol detector, nano quantity aerosol detector, chiral detector and pulsed amperometric detector. These detectors provide accurate concentration analysis, excellent sensitivity, wide dynamic range, consistent response and broad applicability of the drug components. Working of these detectors involve different principles such as optical techniques, aerosol based techniques, refractive methods, light scattering principle, amperometric and fluorescence. The present review enlightens both conventional and advanced techniques and compares their capabilities of analyzing drug components and need for new techniques for better and wide range of applicability.

  19. On-line comprehensive two-dimensional normal-phase liquid chromatography×reversed-phase liquid chromatography for preparative isolation of toad venom.

    Science.gov (United States)

    Li, Jia-Fu; Fang, Hua; Yan, Xia; Chang, Fang-Rong; Wu, Zhen; Wu, Yun-Long; Qiu, Ying-Kun

    2016-07-22

    An on-line comprehensive preparative two-dimensional normal-phase liquid chromatography×reversed-phase liquid chromatography (2D NPLC×RPLC) system was constructed with a newly developed vacuum evaporation assisted adsorption (VEAA) interface, allowing fast removal of NPLC solvent in the vacuum condition and successfully solving the solvent incompatibility problem between NPLC and RPLC. The system achieved on-line solvent exchange within the two dimensions and its performance was illustrated by gram-scale isolation of crude extract from the venom of Bufo bufo gargarizans. Within separation time of ∼20h, 19 compounds were obtained with high purity in a single run. With the VEAA interface, the 2D system exhibited apparent advantages in separation efficiency and automation compared with conventional methods, indicating its promising application in the routine separation process for complicated natural products.

  20. Optimized determination of polybrominated diphenyl ethers by ultrasound-assisted liquid-liquid extraction and high-performance liquid chromatography.

    Science.gov (United States)

    He, Kuang; Lv, YuanCai; Chen, YuanCai

    2014-10-01

    A method based on ultrasound-assisted liquid-liquid extraction and high-performance liquid chromatography has been optimized for the determination of six polybrominated diphenyl ether congeners. The optimal condition relevant to the extraction was first investigated, more than 98.7 ± 0.7% recovery was achieved with dichloromethane as extractant, 5 min extraction time, and three cycles of ultrasound-assisted liquid-liquid extraction. Then multiple function was employed to optimize polybrominated diphenyl ether detection conditions with overall resolution and chromatography signal area as the responses. The condition chosen in this experiment was methanol/water 93:7 v/v, flow rate 0.80 mL/min, column temperature 30.0°C. The optimized technique revealed good linearity (R(2) > 0.9962 over a concentration range of 1-100 μg/L) and repeatability (relative standard deviation liquid-liquid extraction coupled with high-performance liquid chromatography was effective to identify and quantify the complex polybrominated diphenyl ethers in effluent samples.

  1. Classification of cancer cell lines using an automated two-dimensional liquid mapping method with hierarchical clustering techniques.

    Science.gov (United States)

    Wang, Yanfei; Wu, Rong; Cho, Kathleen R; Shedden, Kerby A; Barder, Timothy J; Lubman, David M

    2006-01-01

    A two-dimensional liquid mapping method was used to map the protein expression of eight ovarian serous carcinoma cell lines and three immortalized ovarian surface epithelial cell lines. Maps were produced using pI as the separation parameter in the first dimension and hydrophobicity based upon reversed-phase HPLC separation in the second dimension. The method can be reproducibly used to produce protein expression maps over a pH range from 4.0 to 8.5. A dynamic programming method was used to correct for minor shifts in peaks during the HPLC gradient between sample runs. The resulting corrected maps can then be compared using hierarchical clustering to produce dendrograms indicating the relationship between different cell lines. It was found that several of the ovarian surface epithelial cell lines clustered together, whereas specific groups of serous carcinoma cell lines clustered with each other. Although there is limited information on the current biology of these cell lines, it was shown that the protein expression of certain cell lines is closely related to each other. Other cell lines, including one ovarian clear cell carcinoma cell line, two endometrioid carcinoma cell lines, and three breast epithelial cell lines, were also mapped for comparison to show that their protein profiles cluster differently than the serous samples and to study how they cluster relative to each other. In addition, comparisons can be made between proteins differentially expressed between cell lines that may serve as markers of ovarian serous carcinomas. The automation of the method allows reproducible comparison of many samples, and the use of differential analysis limits the number of proteins that might require further analysis by mass spectrometry techniques.

  2. Application of High Performance Liquid Chromatography to Separation of Novel Chiral Tetrahedral Heterometal Clusters

    Institute of Scientific and Technical Information of China (English)

    Xin Yi ZHU; Wei Qiang ZHANG; Yu Hua ZHANG; Li Ren CHEN; Yong Min LI

    2003-01-01

    A series of novel chiral tetrahedral heterometal clusters have firstly been separated oncellulose tris-(3,5-dimethylphenylcarbamate) stationary phase by high performance liquid chrom-atography, using hexane as the mobile phase with various alcohols as modifiers.

  3. Determination of sulfonamides in butter samples by ionic liquid magnetic bar liquid-phase microextraction high-performance liquid chromatography.

    Science.gov (United States)

    Wu, Lijie; Song, Ying; Hu, Mingzhu; Xu, Xu; Zhang, Hanqi; Yu, Aimin; Ma, Qiang; Wang, Ziming

    2015-01-01

    A novel, simple, and environmentally friendly pretreatment method, ionic liquid magnetic bar liquid-phase microextraction, was developed for the determination of sulfonamides in butter samples by high-performance liquid chromatography. The ionic liquid magnetic bar was prepared by inserting a stainless steel wire into the hollow of a hollow fiber and immobilizing ionic liquid in the micropores of the hollow fiber. In the extraction process, the ionic liquid magnetic bars were used to stir the mixture of sample and extraction solvent and enrich the sulfonamides in the mixture. After extraction, the analyte-adsorbed ionic liquid magnetic bars were readily isolated with a magnet from the extraction system. It is notable that the present method was environmentally friendly since water and only several microliters of ionic liquid were used in the whole extraction process. Several parameters affecting the extraction efficiency were investigated and optimized, including the type of ionic liquid, sample-to-extraction solvent ratio, the number of ionic liquid magnetic bars, extraction temperature, extraction time, salt concentration, stirring speed, pH of the extraction solvent, and desorption conditions. The recoveries were in the range of 73.25-103.85 % and the relative standard deviations were lower than 6.84 %. The experiment results indicated that the present method was effective for the extraction of sulfonamides in high-fat content samples.

  4. Two-Dimensional Numerical Simulations of Ultrasound in Liquids with Gas Bubble Agglomerates: Examples of Bubbly-Liquid-Type Acoustic Metamaterials (BLAMMs).

    Science.gov (United States)

    Vanhille, Christian

    2017-01-17

    This work deals with a theoretical analysis about the possibility of using linear and nonlinear acoustic properties to modify ultrasound by adding gas bubbles of determined sizes in a liquid. We use a two-dimensional numerical model to evaluate the effect that one and several monodisperse bubble populations confined in restricted areas of a liquid have on ultrasound by calculating their nonlinear interaction. The filtering of an input ultrasonic pulse performed by a net of bubbly-liquid cells is analyzed. The generation of a low-frequency component from a single cell impinged by a two-frequency harmonic wave is also studied. These effects rely on the particular dispersive character of attenuation and nonlinearity of such bubbly fluids, which can be extremely high near bubble resonance. They allow us to observe how gas bubbles can change acoustic signals. Variations of the bubbly medium parameters induce alterations of the effects undergone by ultrasound. Results suggest that acoustic signals can be manipulated by bubbles. This capacity to achieve the modification and control of sound with oscillating gas bubbles introduces the concept of bubbly-liquid-based acoustic metamaterials (BLAMMs).

  5. Determination of dodecylbenzenesulphonates and ethoxylated alkylphenols in liquid pesticide formulations by high-performance liquid chromatography.

    Science.gov (United States)

    Schreuder, R H; Martijn, A

    1988-01-01

    A method is presented for determining mixtures of calcium dodecylbenzene-sulphonate (CaDBS) and ethoxylated alkylphenols in pesticidal emulsifiable concentrates. The pesticide formulations are adsorbed on a pre-concentration column. The active ingredients, the solvents and the emulsifiers are eluted successively by using solvents with increasing polarities. The various homologues of CaDBS and the ethoxylated alkylphenols are separated by reversed-phase high performance liquid chromatography using methanol-water containing tetramethylammonium bromide. The oligomers of the ethoxylated phenols are separated on an aminopropyl-modified column using a solvent gradient (propan-2-ol-water and hexane-tetrahydrofuran). Quantitative results are given for synthetic samples. The degree of ethoxylation of the ethoxylated alkylphenols has been determined and the CaDBS components characterized.

  6. Dispersive Liquid-Liquid Microextraction and determination of Platinum(IV by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Ali Mazloomifar

    2015-09-01

    Full Text Available A simple, rapid, and efficient procedure, dispersive liquid-liquid microextraction (DLLME, has been developed for the extraction and preconcentration of platinum (IV in environmental water samples. The factors relevant to the microextraction efficiency, such as the kind and volume of extraction and dispersive solvent, the extraction time, the pH in aqueous, and the salt effect, were optimized. Under the optimum conditions , the enrichment factor of this method for platinum was reached at 119. The detection limit for platinum was 0.3 ng mL-1 , and the relative standard deviation (RSD was 0.42% (n = 10 , C = 10 ng mL-1. The method was successfully applied to the determination of trace amounts of platinum in environmental water samples.

  7. High performance liquid-level sensor based on mPOFBG for aircraft applications

    DEFF Research Database (Denmark)

    Marques, C. A. F.; Pospori, A.; Saez-Rodriguez, D.

    2015-01-01

    A high performance liquid-level sensor based on microstructured polymer optical fiber Bragg grating (mPOFBG) array sensors is reported in detail. The sensor sensitivity is found to be 98pm/cm of liquid, enhanced by more than a factor of 9 compared to a reported silica fiber-based sensor....

  8. Quantitation of triacylglycerols in edible oils by off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column.

    Science.gov (United States)

    Wei, Fang; Hu, Na; Lv, Xin; Dong, Xu-Yan; Chen, Hong

    2015-07-24

    In this investigation, off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column has been applied for the identification and quantification of triacylglycerols in edible oils. A novel mixed-mode phenyl-hexyl chromatographic column was employed in this off-line two-dimensional separation system. The phenyl-hexyl column combined the features of traditional C18 and silver-ion columns, which could provide hydrophobic interactions with triacylglycerols under acetonitrile conditions and can offer π-π interactions with triacylglycerols under methanol conditions. When compared with traditional off-line comprehensive two-dimensional liquid chromatography employing two different chromatographic columns (C18 and silver-ion column) and using elution solvents comprised of two phases (reversed-phase/normal-phase) for triacylglycerols separation, the novel off-line comprehensive two-dimensional liquid chromatography using a single column can be achieved by simply altering the mobile phase between acetonitrile and methanol, which exhibited a much higher selectivity for the separation of triacylglycerols with great efficiency and rapid speed. In addition, an approach based on the use of response factor with atmospheric pressure chemical ionization mass spectrometry has been developed for triacylglycerols quantification. Due to the differences between saturated and unsaturated acyl chains, the use of response factors significantly improves the quantitation of triacylglycerols. This two-dimensional liquid chromatography-mass spectrometry system was successfully applied for the profiling of triacylglycerols in soybean oils, peanut oils and lord oils. A total of 68 triacylglycerols including 40 triacylglycerols in soybean oils, 50 triacylglycerols in peanut oils and 44 triacylglycerols in lord oils have been identified and quantified. The liquid chromatography-mass spectrometry data were analyzed

  9. Crosslinked polymeric ionic liquids as solid-phase microextraction sorbent coatings for high performance liquid chromatography.

    Science.gov (United States)

    Yu, Honglian; Merib, Josias; Anderson, Jared L

    2016-03-18

    Neat crosslinked polymeric ionic liquid (PIL) sorbent coatings for solid-phase microextraction (SPME) compatible with high-performance liquid chromatography (HPLC) are reported for the first time. Six structurally different PILs were crosslinked to nitinol supports and applied for the determination of select pharmaceutical drugs, phenolics, and insecticides. Sampling conditions including sample solution pH, extraction time, desorption solvent, desorption time, and desorption solvent volume were optimized using design of experiment (DOE). The developed PIL sorbent coatings were stable when performing extractions under acidic pH and remained intact in various organic desorption solvents (i.e., methanol, acetonitrile, acetone). The PIL-based sorbent coating polymerized from the IL monomer 1-vinyl-3-(10-hydroxydecyl) imidazolium chloride [VC10OHIM][Cl] and IL crosslinker 1,12-di(3-vinylbenzylimidazolium) dodecane dichloride [(VBIM)2C12] 2[Cl] exhibited superior extraction performance compared to the other studied PILs. The extraction efficiency of pharmaceutical drugs and phenolics increased when the film thickness of the PIL-based sorbent coating was increased while many insecticides were largely unaffected. Satisfactory analytical performance was obtained with limits of detection (LODs) ranging from 0.2 to 2 μg L(-1) for the target analytes. The accuracy of the analytical method was examined by studying the relative recovery of analytes in real water samples, including tap water and lake water, with recoveries varying from 50.2% to 115.9% and from 48.8% to 116.6%, respectively.

  10. Application of Ionic Liquids in High Performance Reversed-Phase Chromatography

    Science.gov (United States)

    Wang, Ye; Tian, Minglei; Bi, Wentao; Row, Kyung Ho

    2009-01-01

    Ionic liquids, considered “green” chemicals, are widely used in many areas of analytical chemistry due to their unique properties. Recently, ionic liquids have been used as a kind of novel additive in separation and combined with silica to synthesize new stationary phase as separation media. This review will focus on the properties and mechanisms of ionic liquids and their potential applications as mobile phase modifier and surface-bonded stationary phase in reversed-phase high performance liquid chromatography (RP-HPLC). Ionic liquids demonstrate advantages and potential in chromatographic field. PMID:19582220

  11. Application of Ionic Liquids in High Performance Reversed-Phase Chromatography

    Directory of Open Access Journals (Sweden)

    Wentao Bi

    2009-06-01

    Full Text Available Ionic liquids, considered “green” chemicals, are widely used in many areas of analytical chemistry due to their unique properties. Recently, ionic liquids have been used as a kind of novel additive in separation and combined with silica to synthesize new stationary phase as separation media. This review will focus on the properties and mechanisms of ionic liquids and their potential applications as mobile phase modifier and surface-bonded stationary phase in reversed-phase high performance liquid chromatography (RP-HPLC. Ionic liquids demonstrate advantages and potential in chromatographic field.

  12. A Method for the Quantitation of Trace Levels of Dimethyl Sulfoxide in Urine by High Performance Liquid Chromatography

    Science.gov (United States)

    1989-05-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY by...for the sample cleanup and concentration, followed by separation by reversed phase high performance liquid chromatography . EXPERIMENTAL Materials...DIMETHYL SULFOXIDE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY 4. AUTHORS (Last name, first name, middle initial. If military, show rank, e.g.

  13. Determination of Dimethyl Sulfoxide (DMSO), Ethanol (ETOH), Formamide (F) and Glycerol/Formal (GF) by High Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    1989-01-30

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC...Classification) (U) Determination of Dimethyl Sulfoxide (DMSO), Ethanol, (ETOH), Formamide (F), and Glycerol/ Formal (GF) by High Performance Liquid Chromatography (HPLC...and 5). High performance liquid chromatography (HPLC) was the analytical method of choice for analyzing DMSO, ethanol, formamide and

  14. Determination of 5-Bromo-2’-Deoxyuridine (BrdU) in Well Water by High Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    1992-09-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC...Securrty Classification) Determination of 5-Bromo-2’-Deoxyuridine (BrdU) in Well Water by High Performance Liquid Chromatography (hPLC) 12. PERSONAL...PLOT OF BrdU STABILITY VERSUS TIME ....................... 10 ii DETERMINATION OF 5-BROMO-2’-DEOXY-URIDINE (BrdU) IN WELL WATER BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

  15. Quality evaluation of moluodan concentrated pill using high-performance liquid chromatography fingerprinting coupled with chemometrics.

    Science.gov (United States)

    Tao, Lingyan; Zhang, Qing; Wu, Yongjiang; Liu, Xuesong

    2016-12-01

    In this study, a fast and effective high-performance liquid chromatography method was developed to obtain a fingerprint chromatogram and quantitative analysis simultaneously of four indexes including gallic acid, chlorogenic acid, albiflorin and paeoniflorin of the traditional Chinese medicine Moluodan Concentrated Pill. The method was performed by using a Waters X-bridge C18 reversed phase column on an Agilent 1200S high-performance liquid chromatography system coupled with diode array detection. The mobile phase of the high-performance liquid chromatography method was composed of 20 mmol/L phosphate solution and acetonitrile with a 1 mL/min eluent velocity, under a detection temperature of 30°C and a UV detection wavelength of 254 nm. After the methodology validation, 16 batches of Moluodan Concentrated Pill were analyzed by this high-performance liquid chromatography method and both qualitative and quantitative evaluation results were achieved by similarity analysis, principal component analysis and hierarchical cluster analysis. The results of these three chemometrics were in good agreement and all indicated that batch 10 and batch 16 showed significant differences with the other 14 batches. This suggested that the developed high-performance liquid chromatography method could be applied in the quality evaluation of Moluodan Concentrated Pill.

  16. DETERMINATION OF CARBENDAZIM IN WATER BY HIGH-PERFORMANCE IMMUNOAFFINITY CHROMATOGRAPHY ON-LINE WITH HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH DIODE-ARRAY OR MASS SPECTROMETRIC DETECTION

    Science.gov (United States)

    An automated method for the determination of carbendazim in water that combines high-performance immunoaffinity chromatography (HPIAC), high-performance liquid chromatography (HPLC) in the reversed-phase mode, and detection by either UV-Vis diode array detector (DAD) spectroscopy...

  17. Proteomic profiling of amniotic fluid in premature labor using two-dimensional liquid separation and mass spectrometry

    Science.gov (United States)

    Bujold, Emmanuel; Romero, Roberto; Kusanovic, Juan Pedro; Erez, Offer; Gotsch, Francesca; Chaiworapongsa, Tinnakorn; Gomez, Ricardo; Espinoza, Jimmy; Vaisbuch, Edi; Kim, Yeon Mee; Edwin, Samuel; Pisano, Mike; Allen, Beth; Podust, Vladimir N.; Dalmasso, Enrique A.; Rutherford, Jennifer; Rogers, Wade; Moser, Allan; Yoon, Bo Hyun; Barder, Tim

    2011-01-01

    Objective Simultaneous analysis of the protein composition of biological fluids is now possible. Such an approach can be used to identify biological markers of disease and to understand the pathophysiology of disorders that have eluded classification, diagnosis, and treatment. The purpose of this study was to analyze the differences in protein composition in amniotic fluid of patients in preterm labor. Study Design Amniotic fluid was obtained by amniocenteses from three groups of women with preterm labor and intact membranes: (1) women without intra-amniotic infection/inflammation (IAI) who delivered at term; (2) women without intra-amniotic IAI who delivered a preterm neonate; and (3) women with IAI. Intra-amniotic infection was defined as a positive amniotic fluid culture for microorganisms. Intra-amniotic inflammation was defined as an elevated amniotic fluid interleukin (IL)-6 (≥2.3 ng/mL). Two-dimensional (2D) chromatography was used for analysis. The first dimension separated proteins by isoelectric point, while the second, by the degree of hydrophobicity. 2D protein maps were generated using different experimental conditions (reducing agents as well as protein concentration). The maps were used to discern subsets of isoelectric point/hydrophobicity containing differentially expressed proteins. Protein identification of differentially expressed fractions was conducted with mass spectrometry. ELISA immunoassays as well as surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS)--based on-chip antibody capture immunoassay were also used for confirmation of a specific protein that was differentially expressed. Results 1) Amniotic fluid protein composition can be analyzed using a combination of 2D liquid chromatography and mass spectrometry for the identification of proteins differentially expressed in patients in preterm labor; 2) While total insulin-like growth factor-binding protein-1 (IGFBP-1) concentration did not change

  18. Proteomic profiling of amniotic fluid in preterm labor using two-dimensional liquid separation and mass spectrometry.

    Science.gov (United States)

    Bujold, Emmanuel; Romero, Roberto; Kusanovic, Juan Pedro; Erez, Offer; Gotsch, Francesca; Chaiworapongsa, Tinnakorn; Gomez, Ricardo; Espinoza, Jimmy; Vaisbuch, Edi; Mee Kim, Yeon; Edwin, Samuel; Pisano, Mike; Allen, Beth; Podust, Vladimir N; Dalmasso, Enrique A; Rutherford, Jennifer; Rogers, Wade; Moser, Allan; Yoon, Bo Hyun; Barder, Tim

    2008-10-01

    Simultaneous analysis of the protein composition of biological fluids is now possible. Such an approach can be used to identify biological markers of disease and to understand the pathophysiology of disorders that have eluded classification, diagnosis, and treatment. The purpose of this study was to analyze the differences in protein composition of the amniotic fluid of patients in preterm labor. Amniotic fluid was obtained by amniocentesis from three groups of women with preterm labor and intact membranes: (1) women without intra-amniotic infection/inflammation (IAI) who delivered at term, (2) women without IAI who delivered a preterm neonate, and (3) women with IAI. Intra-amniotic infection was defined as a positive amniotic fluid culture for microorganisms. Intra-amniotic inflammation was defined as an elevated amniotic fluid interleukin (IL)-6 (> or =2.3 ng/mL). Two-dimensional (2D) chromatography was used for analysis. The first dimension separated proteins by isoelectric point, while the second, by the degree of hydrophobicity. 2D protein maps were generated using different experimental conditions (reducing agents as well as protein concentration). The maps were used to discern subsets of isoelectric point/hydrophobicity containing differentially expressed proteins. Protein identification of differentially expressed fractions was conducted with mass spectrometry. Enzyme-linked immunosorbent assays (ELISA) as well as surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS)-based on-chip antibody capture immunoassays were also used for confirmation of a specific protein that was differentially expressed. (1) Amniotic fluid protein composition can be analyzed using a combination of 2D liquid chromatography and mass spectrometry for the identification of proteins differentially expressed in patients in preterm labor. (2) While total insulin-like growth factor-binding protein-1 (IGFBP-1) concentration did not change, IGFBP-1

  19. On-line comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for preparative isolation of Peucedanum praeruptorum.

    Science.gov (United States)

    Wang, Xin-Yuan; Li, Jia-Fu; Jian, Ya-Mei; Wu, Zhen; Fang, Mei-Juan; Qiu, Ying-Kun

    2015-03-27

    A new on-line comprehensive preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was developed for the separation of complicated natural products. It was based on the use of a silica gel packed medium-pressure column as the first dimension and an ODS preparative HPLC column as the second dimension. The two dimensions were connected with normal-phase (NP) and reversed-phase (RP) enrichment units, involving a newly developed airflow assisted adsorption (AAA) technique. The instrument operation and the performance of this NPLC × RPLC separation method were illustrated by gram-scale isolation of ethanol extract from the roots of Peucedanum praeruptorum. In total, 19 compounds with high purity were obtained via automated multi-step preparative separation in a short period of time using this system, and their structures were comprehensively characterized by ESI-MS, (1)H NMR, and (13)C NMR. Including two new compounds, five isomers in two groups with identical HPLC and TLC retention values were also obtained and identified by 1D NMR and 2D NMR. This is the first report of an NPLC × RPLC system successfully applied in an on-line preparative process. This system not only solved the interfacing problem of mobile-phase immiscibility caused by NP and RP separation, it also exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods.

  20. Two-dimensional liquid chromatography (LC) of phenolic compounds from the shoots of Rubus idaeus 'Glen Ample' cultivar variety.

    Science.gov (United States)

    Kula, Marta; Głód, Daniel; Krauze-Baranowska, Mirosława

    2016-03-20

    In this study the application of two-dimensional LC (2D LC) for qualitative analysis of polyphenols and simple phenols in the shoots of Rubus idaeus 'Glen Ample' variety is presented. In the preliminary analysis, the methanol extract of the shoots was analyzed by one-dimensional LC. One-dimensional LC separation profiles of phenolics from R. idaeus 'Glen Ample' shoots were dependent on column type, mobile phase composition and gradient program used. Two-dimensional LC system was built from connecting an octadecyl C-18 silica column in the first dimension and pentafluorophenyl column in the second dimension, coupled with DAD and MS (ESI, APCI, DUIS ionization) detectors. A total of 34 phenolic compounds belonging to the groups of phenolic acids, ellagitannins, flavan-3-ols, flavonols and ellagic acid conjugates were identified in the shoots of R. idaeus 'Glen Ample'. The established 2D LC method offers an effective tool for analysis of phenolics present in Rubus species.

  1. Comprehensive two-dimensional liquid chromatography with ultraviolet, evaporative light scattering and mass spectrometric detection of triacylglycerols in corn oil

    NARCIS (Netherlands)

    Klift, van der E.J.C.; Vivó-Truyols, G.; Claassen, F.W.; Holthoon, van F.L.; Beek, van T.A.

    2008-01-01

    An improved comprehensive two-dimensional (LC × LC) HPLC system for the analysis of triacylglycerols was developed. In the first-dimension, a Ag(I)-coated cation exchanger (250 mm × 2.1 mm, 5 ¿m) was employed with a gradient from 100% MeOH to 6% MeCN in MeOH at 20 ¿L/min. Using a 10-way valve with t

  2. High-performance liquid chromatography analysis methods developed for quantifying enzymatic esterification of flavonoids in ionic liquids

    DEFF Research Database (Denmark)

    Lue, Bena-Marie; Guo, Zheng; Xu, X.B.

    2008-01-01

    Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found ...

  3. Monitoring stevioside in soju by high-performance liquid chromatography and liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Ni, Fan; Ammann, Jeffrey; Mabud, Abdul

    2007-01-01

    A method using high-performance liquid chromatography (HPLC) with UV absorption detection was developed to monitor stevioside in soju, a distilled spirits product that is commercially available. The method uses a single-step dilution for sample preparation. It completely eliminates the time-consuming process of solid-phase extraction. A method using HPLC/mass spectrometry was optimized to confirm the identities of stevioside and other related impurities, including rebaudioside A, rebaudioside C, and dulcoside. The method was validated. The validation parameters included range (10.1-1007.3 ppm), precision, linearity, accuracy, robustness, system suitability, and intermediate precision. Stevioside standard solutions at 6 concentration levels were prepared for the validation work, including the tests for precision, linearity, and accuracy. The solutions were prepared in triplicate for each concentration. The relative standard deviation for the precision test was 0.999. The average recovery ranged from 95.7 to 101.1% for the soju samples spiked with stevioside standard. The detection limit for stevioside was estimated at 75 ppb. The method was used to screen several soju samples; no detectable stevioside was found in the samples.

  4. High-performance liquid chromatography of oligoguanylates at high pH

    Science.gov (United States)

    Stribling, R.; Deamer, D. (Principal Investigator)

    1991-01-01

    Because of the stable self-structures formed by oligomers of guanosine, standard high-performance liquid chromatography techniques for oligonucleotide fractionation are not applicable. Previously, oligoguanylate separations have been carried out at pH 12 using RPC-5 as the packing material. While RPC-5 provides excellent separations, there are several limitations, including the lack of a commercially available source. This report describes a new anion-exchange high-performance liquid chromatography method using HEMA-IEC BIO Q, which successfully separates different forms of the guanosine monomer as well as longer oligoguanylates. The reproducibility and stability at high pH suggests a versatile role for this material.

  5. DETERMINATION OF ENZYME-ACTIVITY BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

    NARCIS (Netherlands)

    WELLING, GW; SCHEFFER, AJ; WELLINGWESTER, S

    1994-01-01

    The application of high-performance liquid chromatography (HPLC) in the study of enzymatic reactions is reviewed. The rationale for using HPLC is given and whether the components of the reaction mixture should be derivatized prior to or after HPLC. An alphabetical list of enzymes assayed by HPLC is

  6. High-performance liquid chromatography of rat and mouse islet polypeptides

    DEFF Research Database (Denmark)

    Linde, S; Hansen, B; Welinder, B S

    1990-01-01

    After preparative high-performance liquid chromatography of mouse islet culture medium, concentrated on disposable C18 cartridges (Sep-Pak), an unexpected insulin immunoreactive peak eluting earlier than mouse insulin I and II was detected. Molecular mass determination by mass spectrometry...

  7. Going Beyond, Going Further: An Inexpensive Experiment for the Introduction of High Performance Liquid Chromatography.

    Science.gov (United States)

    Bidlingmeyer, Brian A.; Warren, F. Vincent, Jr.

    1984-01-01

    Background information, materials needed, laboratory procedures, and typical results are provided for five high performance liquid chromatography experiments (three isocratic and two step gradient separations). Suggestions for further experimentation are also provided, including quantitative determinations and separation of charged solutes. (JN)

  8. Extraction and Purification of Glucoraphanin by Preparative High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Lee, Iris; Boyce, Mary C.

    2011-01-01

    A student activity that focuses on the isolation of glucoraphanin from broccoli using preparative high-performance liquid chromatography (HPLC) is presented here. Glucoraphanin is a glucosinolate, whose byproducts are known to possess anticancer properties. It is present naturally at high levels in broccoli and other "Brassica" vegetables. This…

  9. High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory

    Science.gov (United States)

    Frey, Douglas D.; Guo, Hui; Karnik, Nikhila

    2013-01-01

    This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…

  10. DETERMINATION OF CHLOROPHENOLS, NITROPHENOLS, AND METHYLPHENOLS IN GROUND-WATER SAMPLES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Science.gov (United States)

    A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...

  11. Determination of low molecular weight thiols using monobromobimane fluorescent labeling and high-performance liquid chromatography

    Science.gov (United States)

    Fahey, Robert C.; Newton, Gerald L.

    1988-01-01

    Methods are described for the preparation and high-performance liquid chromatography (HPLC) analysis of monobromobimane derivatives of low molecular weight thiols in extracts of biological samples. Typical problems encountered in the development and application of these methods are discussed. Analysis of mung bean extract is used as an example.

  12. Sugar Determination in Foods with a Radially Compressed High Performance Liquid Chromatography Column.

    Science.gov (United States)

    Ondrus, Martin G.; And Others

    1983-01-01

    Advocates use of Waters Associates Radial Compression Separation System for high performance liquid chromatography. Discusses instrumentation and reagents, outlining procedure for analyzing various foods and discussing typical student data. Points out potential problems due to impurities and pump seal life. Suggests use of ribose as internal…

  13. Experimental hydrophobicity parameters of perfluorinated alkylated substances from reversed-phase high performance liquid chromatography

    NARCIS (Netherlands)

    de Voogt, P.; Zurano, L.; Serné, P.; Haftka, J.J.H.

    2012-01-01

    Capacity factors of perfluorinated alkylated substances were obtained from isocratic reversed-phase high-performance liquid chromatography-mass spectrometry experiments at different organic modifier strengths of the mobile phase. The resulting capacity factor v. modifier strengths plots were extrapo

  14. Determination of rafoxanide and closantel in ovine plasma by high performance liquid chromatography.

    Science.gov (United States)

    Benchaoui, H A; McKellar, Q A

    1993-01-01

    A high performance liquid chromatographic method has been developed for the determination of rafoxanide and closantel in ovine plasma. Acetonitrile and chloroform were used for the extraction. The mean recoveries were 78.69% and 80.59% for rafoxanide and closantel, respectively. This method was applied to the characterization of rafoxanide plasma kinetics following oral administration of therapeutic doses to sheep.

  15. Comparison of high performance liquid chromatography and enzymatic analysis of soluble carbohydrates in loblolly pine

    Science.gov (United States)

    Patricia L. Faulkner; Michele M. Schoeneberger; Kim H. Ludovici

    1993-01-01

    Foliar tissue was collected from a field study designed to test impacts of atmospheric pollutants on loblolIy pine (Pinus taeda L.) seedlings. Standard enzymatic (ENZ) and high performance liquid chromatography (HPLC) methods were used to analyze the tissue for soluble sugars. A comparison of the methods revealed no significant diffennces in accuracy...

  16. New methods and materials for solid phase extraction and high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Dumont, Philip John [Iowa State Univ., Ames, IA (United States)

    1996-04-23

    This paper describes methods for solid phase extraction and high performance liquid chromatography (HPLC). The following are described: Effects of Resin Sulfonation on the Retention of Polar Organic Compounds in Solid Phase Extraction; Ion-Chromatographic Separation of Alkali Metals In Non-Aqueous Solvents; Cation-Exchange Chromatography in Non-Aqueous Solvents; and Silicalite As a Stationary Phase For HPLC.

  17. An Advanced, Interactive, High-Performance Liquid Chromatography Simulator and Instructor Resources

    Science.gov (United States)

    Boswell, Paul G.; Stoll, Dwight R.; Carr, Peter W.; Nagel, Megan L.; Vitha, Mark F.; Mabbott, Gary A.

    2013-01-01

    High-performance liquid chromatography (HPLC) simulation software has long been recognized as an effective educational tool, yet many of the existing HPLC simulators are either too expensive, outdated, or lack many important features necessary to make them widely useful for educational purposes. Here, a free, open-source HPLC simulator is…

  18. Quantification of six bioactive compounds in Zhenqi Fuzheng preparation by high-performance liquid chromatography couple

    Institute of Scientific and Technical Information of China (English)

    Yi-Kai Shi; Fang Cui; Fang-Di Hu; Ying-Yan Bi; Yu-Feng Ma; Shi-Lan Feng

    2011-01-01

    A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The

  19. High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory

    Science.gov (United States)

    Frey, Douglas D.; Guo, Hui; Karnik, Nikhila

    2013-01-01

    This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…

  20. An on-line high performance liquid chromatography-crocin bleaching assay for detection of antioxidants

    NARCIS (Netherlands)

    Bountagkidou, O.; Klift, van der E.J.C.; Tsimidou, M.Z.; Ordoudi, S.A.; Beek, van T.A.

    2012-01-01

    An on-line HPLC (high performance liquid chromatography) method for the rapid screening of individual antioxidants in mixtures was developed using crocin as a substrate (i.e. oxidation probe) and 2,2'-azobis(2-amidinopropane dihydrochloride (AAPH)) in phosphate buffer (pH 7.5) as a radical generator

  1. High Performance Liquid Chromatographic Analysis of Phytoplankton Pigments Using a C16-Amide Column

    Science.gov (United States)

    A reverse-phase high performance liquid chromatographic (RP-HPLC) method was developed to analyze in a single run, most polar and non-polar chlorophylls and carotenoids from marine phytoplankton. The method is based on a RP-C16-Amide column and a ternary gradient system consistin...

  2. Extraction and Purification of Glucoraphanin by Preparative High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Lee, Iris; Boyce, Mary C.

    2011-01-01

    A student activity that focuses on the isolation of glucoraphanin from broccoli using preparative high-performance liquid chromatography (HPLC) is presented here. Glucoraphanin is a glucosinolate, whose byproducts are known to possess anticancer properties. It is present naturally at high levels in broccoli and other "Brassica" vegetables. This…

  3. Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    Science.gov (United States)

    Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: alachlor ethanesulfonic acid (ESA); alachlor oxanilic acid; acetochlor ESA; acetochlor oxanilic acid; metolachlor ESA; and metolachlor oxanilic acid. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The average HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.5 and 2.0 ??g/l ranged from 84 to 112%, with relative standard deviations of 18% or less. The average HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.2 and 2.0 ??g/l ranged from 81 to 118%, with relative standard deviations of 20% or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 ??g/l, whereas the LOQ using the HPLC/MS method was at 0.05 ??g/l. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water. Copyright (C) 2000 Elsevier Science B.V.

  4. Chemical fingerprint of Ganmaoling granule by double-wavelength ultra high performance liquid chromatography and ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Lou, Qiong; Ye, Xiaolan; Zhou, Yingyi; Li, Hua; Song, Fenyun

    2015-06-01

    A method incorporating double-wavelength ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry was developed for the investigation of the chemical fingerprint of Ganmaoling granule. The chromatographic separations were performed on an ACQUITY UPLC HSS C18 column (2.1 × 50 mm, 1.8 μm) at 30°C using gradient elution with water/formic acid (1%) and acetonitrile at a flow rate of 0.4 mL/min. A total of 11 chemical constituents of Ganmaoling granule were identified from their molecular weight, UV spectra, tandem mass spectrometry data, and retention behavior by comparing the results with those of the reference standards or literature. And 25 peaks were selected as the common peaks for fingerprint analysis to evaluate the similarities among 25 batches of Ganmaoling granule. The results of principal component analysis and orthogonal projection to latent structures discriminant analysis showed that the important chemical markers that could distinguish the different batches were revealed as 4,5-di-O-caffeoylquinic acid, 3,5-di-O-caffeoylquinic acid, and 4-O-caffeoylquinic acid. This is the first report of the ultra high performance liquid chromatography chemical fingerprint and component identification of Ganmaoling granule, which could lay a foundation for further studies of Ganmaoling granule.

  5. Salting-out assisted liquid-liquid extraction coupled to dispersive liquid-liquid microextraction for the determination of chlorophenols in wine by high-performance liquid chromatography.

    Science.gov (United States)

    Fan, Yingying; Hu, Shibin; Liu, Shuhui

    2014-12-01

    A novel procedure of sample preparation combined with high-performance liquid chromatography with diode array detection is introduced for the analysis of highly chlorinated phenols (trichlorophenols, tetrachlorophenols, and pentachlorophenol) in wine. The main features of the proposed method are (i) low-toxicity diethyl carbonate as extraction solvent to selectively extract the analytes without matrix effect, (ii) the combination of salting-out assisted liquid-liquid extraction and dispersive liquid-liquid microextraction to achieve an enrichment factor of 334-361, and (iii) the extract is analyzed by high-performance liquid chromatography to avoid derivatization. Under the optimum conditions, correlation coefficients (r) were >0.997 for calibration curves in the range 1-80 ng/mL, detection limits and quantification limits ranged from 0.19 to 0.67 and 0.63 to 2.23 ng/mL, respectively, and relative standard deviation was wines, with recovery rates in the range 82-104%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Two-dimensional liquid chromatography coupled to tandem mass spectrometry for vitamin D metabolite profiling including the C3-epimer-25-monohydroxyvitamin D3.

    Science.gov (United States)

    Mena-Bravo, A; Priego-Capote, F; Luque de Castro, M D

    2016-06-17

    A method based on automated on-line solid phase extraction coupled to two-dimensional liquid chromatography with tandem mass spectrometry detection (SPE-2DLC-MS/MS) is here reported for vitamin D metabolite profiling in human serum with absolute quantitation. Two-dimensional LC was configured with two complementary analytical columns, pentafluorophenyl (PFP) and C18 phases, for determination of 25 hydroxyvitamin D3 epimers and the resting bioactive metabolites of vitamin D (D3 and D2)-25-hydroxyvitamin D2, 1,25-dihydroxyvitamin D3, 1,25-dihydroxyvitamin D2 and 24,25-dihydroxyvitamin D3. Quantitative determination was supported on the use of a stable isotopic labelled internal standard for each analyte and the resulting method was validated by analysis of a standard reference material certified by the National Institute of Standards & Technology (NIST-972a) and 5 samples provided by the vitamin D External Quality Assurance Scheme (DEQAS). The limits of detection were between 9 and 90pg/mL for the eight analytes, and precision, expressed as relative standard deviation, was lower than 11.6%. Two-dimensional LC has shown to be the key to discriminate between 25 hydroxyvitamin D3 epimers in a quantitative analysis also involving dihydroxyvitamin D metabolites.

  7. Analysis of chlorpheniramine in human urine samples using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Mehdi Maham

    2014-09-01

    Full Text Available A simple and environmentally friendly microextraction technique was used for determination of chlorpheniramine (CPM, an antihistamine drug, in human urine samples using dispersive liquid-liquid microextraction (DLLME followed by high performance liquid chromatography with diode array detection (HPLC-DAD. In this extraction technique, an appropriate mixture of acetonitrile (disperser solvent and carbon tetrachloride (extraction solvent was rapidly injected into the urine sample containing the target analyte. Tiny droplets of extractant were formed and dispersed into the sample solution and then sedimented at the bottom of the conical test tube by centrifugation. Under optimal conditions, the calibration curve was linear in the range of 0.055-5.5 µg mL-1, with a detection limit of 16.5 ng mL-1. This proposed method was successfully applied to the analysis of real urine samples. Low consumption of toxic organic solvents, simplicity of operation, low cost and acceptable figures of merit are the main advantages of the proposed technique.

  8. Separation of Nitration By-Products in Commercial-Grade Trinitro-Toluene by High Performance Liquid Chromatography.

    Science.gov (United States)

    1982-06-01

    MRL-TN-464 SEPARATION OF NITRATION BY-PRODUCTS IN COMMERCIAL-GRADE TITR-TOLUENE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Peter J. Sanders ABSTRACT...UNCLASSIFIED TITLE SEPARATION OF NITRATION BY-PRODUCTS IN COMMERCIAL-GRADE TRXNITRO-TOLUENE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY AUTHOR(S...PRODUCTS IN COMMERCIAL-GRADE TRINITRO-TOLUENE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY 16 INTRODUCTION Fbr some time, a need has existed for the

  9. [Qualitative and quantitative analysis of the amino acids in Rhizoma Arisaematis by ultra high performance liquid chromatography-tandem mass spectrometry and high performance liquid chromatography].

    Science.gov (United States)

    Wang, Xing; Chi, Yumei; Kang, An

    2014-12-01

    A method for the identification and determination of the polar amino components without ultraviolet activity in traditional Chinese medicines was developed. With Rhizoma Arisaematis as the object of this study, using pre-column derivatization with phenyl isothiocyanate (PITC) as the derivatization reagent, compounds were separated and identified on a C18 column (100 mm x 2.1 mm, 3.5 µm) by ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). A total of 20 components, including 18 amino acids and 2 amine compounds were identified. Furthermore, after the optimization of the derivatization conditions, 15 amino acids were determined by high performance liquid chromatography (HPLC) on Diamonsil C18 column (250 mm x 4.6 mm, 5 µm), detected at 254 nm and gradiently eluted by acetonitrile and 0. 05 mol/L ammonium acetate-acetic acid (pH 6. 5) as the mobile phases. The results of methodological study demonstrated that the method can meet the requirements of the determination. All calibration curves expressed good linearity: Glu, Try in the range of 2-100 mg/L, Arg in the range of 6-300 mg/L, others in the range of 0. 8-40 µg/L, with the correlation coefficients ≥ 0. 999 5. The average recovery of this method was among 95%-105% and the RSD was less than 3%. The developed method was successfully applied to quantitative determination of amino compounds in 12 batches of Rhizoma Arisaematis samples. The method is simple, sensitive, accurate, and can be used for rapid identification and determination of amino components in traditional Chinese medicines.

  10. Multidimensional high-performance liquid chromatography on Pinkerton ISRP and RP18 columns: direct serum injection to quantify creatinine.

    Science.gov (United States)

    Puhlmann, A; Dülffer, T; Kobold, U

    1992-10-02

    A two-dimensional high-performance liquid chromatographic method for the determination of creatinine with direct serum injection without sample pretreatment has been developed. The column-switching technique allowed a switch from columns packed with internal surface reversed-phase (ISRP) material to columns of almost any other material, even if the eluents necessary in a particular case do not appear to be directly compatible. A Pinkerton ISRP column, which stands out because of its very good stability when loaded with undiluted serum samples, was used as precolumn. The creatinine-containing fraction was switched to a reversed-phase Shandon RP18 column and was focused there by alteration of the eluent from pH 6.5 to phosphoric acid-ion-pair reagent. The separation occurs via a pH gradient, with ultraviolet detection at 234 nm. This method stands out particularly for its good long-term stability, simple sample handling without pretreatment, high selectivity, a broad linearity (0.3-30 mg/dl creatinine), good reproducibility (inter-assay coefficient of variation less than 3%) and high recovery (97-100%) relative to values obtained with gas chromatography-mass spectrometry.

  11. Determination of acaricides in honey by high-performance liquid chromatography with photodiode array detection.

    Science.gov (United States)

    Martel, Anne-Claire; Zeggane, Sarah

    2002-04-19

    Rapid analytical methods are described to control quality of honeys, concerning residues of acaricides applied in hives to prevent Varroa jacobsoni infestation. A liquid-liquid extraction with hexane-propanol-2-ammonia (60 ml:30 ml:0.28%) was used for the simultaneous analysis of coumaphos, bromopropylate, amitraz and fluvalinate. For thymol, one clean up on a solid-phase extraction C18 (500 mg, 6 ml) column was performed; for rotenone, a liquid extraction with dichloromethane was realised. Quantitative recoveries obtained with honey were satisfactory and were superior to 80%. All acaricides are identified by reversed-phase high-performance liquid chromatography with photodiode array detection. Quantification limits obtained were below maximal residue limits when these exist.

  12. Ionic Liquids as Mobile Phase Additives for Separation of Nucleotides in High-Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    ZHANG,Wen-Zhu(张文珠); HE,Li-Jun(何丽君); LIU,Xia(刘霞); JIANG,Sheng-Xiang(蒋生祥)

    2004-01-01

    Ionic liquids are a type of salts that are liquid at low temperature (< 100 ℃). Because of their some special properties, they have been widely used as new "green solvents" for many chemical reactions and liquid-liquid extraction in the past several years. In this paper, a new method for the separation of nucleotides is developed and the essential feature of the method is that 1-alkyl-3-methylimidazolium salts are used as mobile phase additives, resulting in a baseline separation of nucleotides without need of gradient elution and need of organic solvent addition as currently used in RP-HPLC. This study shows the potential application of ionic liquids as mobile phase additives in reversed-phase liquid chromatography.

  13. Analyses of acute kidney injury biomarkers by ultra-high performance liquid chromatography with mass spectrometry.

    Science.gov (United States)

    Al Za'abi, Mohammed; Ali, Badreldin H; ALOthman, Zeid A; Ali, Imran

    2016-01-01

    The newly developed acute kidney injury biomarkers are very important for the early and timely detection of kidney diseases. This review contains details of the analyses of several acute kidney injury biomarkers using ultra-high performance liquid chromatography-mass spectrometry in urine and plasma samples. In this review we attempt to discuss some aspects of the types of the biomarkers, patents, sample preparation, and the analyses. Besides, efforts were also made to discuss the possible uses of superficially porous (core-shell) columns in traditional and inexpensive high-performance liquid chromatography instruments. Additionally, the challenges and the future prospects are also highlighted. The present review will be useful for the academicians, scientists, and clinicians for the early detection of acute kidney injury biomarkers.

  14. Homochiral metal-organic framework used as a stationary phase for high-performance liquid chromatography.

    Science.gov (United States)

    Kong, Jiao; Zhang, Mei; Duan, Ai-Hong; Zhang, Jun-Hui; Yang, Rui; Yuan, Li-Ming

    2015-02-01

    Metal-organic frameworks are promising porous materials. Chiral metal-organic frameworks have attracted considerable attention in controlling enantioselectivity. In this study, a homochiral metal-organic framework [Co(2) (D-cam)(2) (TMDPy)] (D-cam = D-camphorates, TMDPy = 4,4'-trimethylenedipyridine) with a non-interpenetrating primitive cubic net has been used as a chiral stationary phase in high-performance liquid chromatography. It has allowed the successful separation of six positional isomers and six chiral compounds. The good selectivity and baseline separation, or at least 60% valley separation, confirmed its excellent molecular recognition characteristics. The relative standard deviations for the retention time of run-to-run and column-to-column were less than 1.8 and 3.1%, respectively. These results demonstrate that [Co(2) (D-cam)(2) (TMDPy)] may represent a promising chiral stationary phase for use in high-performance liquid chromatography.

  15. Determination of Polysaccharide in Radix pseudostellariae Extract by Size-Exclusion High-Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A simple size-exclusion high-performance liquid chromatographic method was developed for rapid molecular mass screening to determine the average molecular mass, polydispersity, and quantity of Taizishen polysaccharides extract. The screening used a TOSOH TSK-GEL G3000SW high-performance liquid chromatographic column with 0.1 mol/L NaNO3 buffer as the mobile phase and refractive index detector. The molecular mass calibration curve was linear for polysaccharide standards from 10 to 100 kDa with a correlation coefficient of 0.9991. The method can be used to analyze the quantity, average molecular mass,and polydispersity of polysaccharides. In addition, the screening method is suitable for quality control of polysaccharide preparations in Chinese medicines and pharmaceutical products.

  16. Determination of fenbendazole, praziquantel and pyrantel pamoate in dog plasma by high-performance liquid chromatography.

    Science.gov (United States)

    Morovján, G; Csokán, P; Makranszki, L; Abdellah-Nagy, E A; Tóth, K

    1998-02-27

    Simple and rapid high-performance liquid chromatographic methods were developed for the determination of fenbendazole, praziquantel and pyrantel pamoate in dog plasma. The combination of these drugs is the most powerful treatment against most types of worms. Blood plasma samples obtained in a pharmacokinetic trial were prepared using solid-phase extraction. Fenbendazole and praziquantel were analyzed simultaneously by reversed-phase high-performance liquid chromatography on an octadecyl-modified silica stationary phase employing acetonitrile-phosphate buffer (pH 3.0) eluent and ultraviolet detection at 220 nm. Pyrantel was analyzed separately on a base-deactivated reversed-phase column using methanol-tetrahydrofuran-ammonium acetate buffer (pH 4.6) eluent and ultraviolet detection at 317 nm. Average recoveries for fenbendazole, praziquantel and pyrantel pamoate were 76.8, 93.4 and 90.5%, respectively. Limits of quantitation were in the range of 15-25 ng/ml plasma.

  17. Serum Protein Profile Study of Clinical Samples Using High Performance Liquid Chromatography-Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Ukendt, Sujatha; Rai, Lavanya

    2009-01-01

    The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested for estab......The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested...... for establishing the ability of HPLC-LIF protein profiling technique for discrimination, using hard clustering and Fuzzy clustering methods. The clustering algorithms have quite successfully classified the profiles as belonging to normal, cancer of cervix, and oral cancer conditions....

  18. High Performance Liquid Chromatographic Method for Determination of Dipyridamole in Human Plasma

    Directory of Open Access Journals (Sweden)

    DAVOOD BEIGI BAND ARAB ADI

    1999-08-01

    Full Text Available A simple, rapid and specific high-performance liquid chromatographic procedure is reported for"nquantitative determination of dipyridamole in human -plasma. The assay uses a reversed-phase"nhigh-performance liquid chromatographic (HPLC and UV detection at 280nm and has a limit"nof detection of approximately 5ng/mL. The mobile phase consists of MeOH-H20 (60:40"nadjusted to pH 3.3. Dipyridamole was extracted from plasma by back-extraction procedure, with"npropranolol as the internal standard. The reproducibility of the method is satisfactory

  19. The Application of High Performance Liquid Chromatography in the Analysis of Trace Rare Earth

    Institute of Scientific and Technical Information of China (English)

    WANG; Xiu-feng; DING; You-qian

    2012-01-01

    <正>Rare earth elements are very important in the field of radioanalytical chemistry, for it must be separated and determined in the measurements of burn-up and fission yield. High performance liquid chromatography has become a main method in the separation of rare earth elements due to its obvious advantages, this is, high speed of analysis, high efficiency and easy automation. The ion exchange chromatography is the main means to separate rare earth elements, especially the cation exchange

  20. Determination of pentachlorophenol in water and aquifer sediments by high-performance liquid chromatography

    Science.gov (United States)

    Goerlitz, D.F.

    1981-01-01

    Methods for the determination of pentachlorophenol (PCP) in water and aquifer sediments are presented. Reverse-phase high-performance liquid chromotography employing ion suppression and gradient elution is used. PCP can be determined directly in water at a lower limit of detection Of 0.2 micrograms per liter. For extracts of sediment, PCP can be determined to a lower limit of 1.0 micrograms per kilogram.

  1. Resolution of the stereoisomers of baclofen by high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Weatherby, R.P.; Allan, R.D.; Johnston, G.A.R. (Sydney Univ. (Australia))

    1984-01-01

    The GABA analogue baclofen (3-(p-chlorophenyl)-4-aminobutanoic acid) has stereospecific actions on the peripheral and central nervous systems. This paper describes the resolution of tritium-labelled baclofen by high performance liquid chromatography on a reverse-phase C18 column using a chiral mobile phase. The method, which may have general application to certain other GABA analogues, affords optically pure (+)- and (-)-baclofen labelled with tritium to high specific activity suitable for ligand binding and other neurochemical studies.

  2. A simple high performance liquid chromatography method for determination of rebamipide in rat urine

    OpenAIRE

    Cooper, Dustin L.; Harirforoosh, Sam

    2014-01-01

    Rebamipide is a mucoprotective agent commonly used to prevent nonsteriodal anti-inflammatory drug-induced gastrointenstinal side effects [1]. Human plasma and urine analysis of rebamipide utilizing high performance liquid chromatography (HPLC) have been reported [2]. Recently, we reported on the plasma levels of rebamipide in presense or absence of celecoxib or diclofenac in rats [3] using a modified HPLC method of detection developed by Jeoung et al. [4]. To tailor the method towards use in ...

  3. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods

    OpenAIRE

    Wei Liu; Dongmei Wang; Jianjun Liu; Dengwu Li; Dongxue Yin

    2016-01-01

    The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC) fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichua...

  4. [Comparison of refractometric and ultraviolet detection methods in lactulose assay by high performance liquid chromatography].

    Science.gov (United States)

    Vaccher, C; Berthelot, P; Flouquet, N; Debaert, M

    1990-01-01

    Dosage of lactulose and determination of related sugars (lactose, fructose, galactose, épilactose) were undertaken by high performance liquid chromatography (HPLC). The present note described two modes of detection used simultaneously and compared: refractive index detector (RI) and multiwavelength ultraviolet detector (UV). HPLC is performed with an aminopropylsylil phase as stationary phase and an isocratic mobile phase containing acetonitrile and aqueous sodium phosphate. The results are outlined and discussed.

  5. DETERMINATION OF PROTEINS FROM BUFFALO MILK USING HIGH PERFORMANCE LIQUID CROMATOGRAPHY RP-HPLC

    OpenAIRE

    AURELIA PECE; COROIAN C.; BIANCA GHIRILĂ; G. MURESAN; VIOARA MIRESAN

    2013-01-01

    In the hereby paper, we have undertaken a study on buffalo milk proteins, employing high performance liquid chromatography (HPLC). This RP-HPLC technique is commonly employed in the separation and assessment of caseins K, and in the fresh, as well as processed milk. These methods are also successfully applied in the authenticity and origin assessment of certain cheese products and the qualitative analysis of milk in bubalines, ovines, caprines and bovines (Ferreira si Cacote, 2003; Veloso si...

  6. Surface Confined Ionic Liquid-A New Stationary Phase for the Separation of Ephedrines in High-performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    Shu Juan LIU; Feng ZHOU; Xiao Hua XIAO; Liang ZHAO; Xia LIU; Sheng Xiang JIANG

    2004-01-01

    In this article, a new and effective stationary phase based on ionic liquid modified silica is first reported and used for the separation of ephedrines in high-performance liquid chromatography (HPLC). The separation results indicate the high efficiency and reproducibility of the stationary phase. The electrostatic interaction, ion-exchange interaction between the solutes and the stationary phase are considered to attribute the effective separation. Moreover, the free silanols on the surface of the silica are effectively masked by the immobilized ionic liquid, a result of which is to decrease the non-specific absorption.

  7. Development of molecular imprinted column-on line-two dimensional liquid chromatography for selective determination of clenbuterol residues in biological samples.

    Science.gov (United States)

    Guo, Pengqi; Luo, Zhimin; Xu, Xinya; Zhou, Yulan; Zhang, Bilin; Chang, Ruimiao; Du, Wei; Chang, Chun; Fu, Qiang

    2017-02-15

    A novel method coupling molecular imprinted monolithic column with two-dimensional liquid chromatography was developed and validated for the analysis of clenbuterol in pork liver and swine urine samples. The polymers were characterized by using Fourier transform infrared spectroscopy, nitrogen adsorption desorption analyses, frontal analysis and the adsorption of selectivity. The results indicated that the imprinted columns were well prepared and possessed high selectivity adsorption capacity. Subsequently, the MIMC-2D-LC (molecular imprinted monolithic column-two dimensional liquid chromatography) method was developed for the selective analysis of clenbuterol in practical samples. The accuracy ranged from 94.3% to 99.7% and from 93.7% to 99.6% for liver and urine, respectively. The relative standard deviation (RSD) of repeatability was lower than 8.6% for both analyses. The limit of detections was 16ng·mL(-1) for liver and 25ng·mL(-1) for urine, respectively. Compared with the reported methods, the disturbance of endogenous impurity could be avoided by the 2D-LC method.

  8. Isolation and purification of heroin from heroin street samples by preparative high performance liquid chromatography.

    Science.gov (United States)

    Guo, Zhen; Zheng, Hui; Lu, Yanzhen; Wei, Yun

    2012-09-10

    The present study established a novel method using preparative high performance liquid chromatography to isolate and purify heroin·HCl from heroin street samples to be used as a reference standard. Different kinds of mobile phases and columns were used, ultimately the mobile phase consisting of hexane-isopropanol-methanol (65:28:7, v/v) and the SIL preparative column prepared in laboratory were selected as the final condition. Heroin was further purified by the drowning-out crystallization method using isopropanol-methanol (50:1, v/v) and hexane as drowning-out anti-solvents and salting-out agents, respectively. The purity was assessed by analytical high performance liquid chromatography and the confirmation of the chemical structure was performed by IR and NMR. About 110.7mg of heroin·HCl at a purity of over 99.52% was obtained from 180mg of heroin street samples which contained 156.15mg of heroin·HCl component by preparative high performance liquid chromatography. This method is suitable for preparing heroin standards in forensic science area.

  9. In Silico Modeling of Hundred Thousand Experiments for Effective Selection of Ionic Liquid Phase Combinations in Comprehensive Two-Dimensional Gas Chromatography.

    Science.gov (United States)

    Nolvachai, Yada; Kulsing, Chadin; Marriott, Philip J

    2016-02-16

    The selection of the best column sets is one of the most tedious processes in comprehensive two-dimensional gas chromatography (GC × GC) where a multitude of choices of column sets could be employed for an individual sample analysis. We demonstrate analyte/stationary phase dependent selection approaches based on the linear solvation energy relationship (LSER), which is a reliable concept for the study of interaction mechanisms and retention prediction with a large database pool of columns and compounds. Good correlations between our predicted results, with experimental results reported in the literature, were obtained. The developed approaches were applied to the simulation of 157 920 individual experiments in GC × GC, focusing on the application of 30 nonionic liquid and 111 ionic liquid (IL) stationary phases for separation of some example sets of model compounds present in practical samples. The best column sets for each sample separation could then be extracted according to maximizing orthogonality, which estimates the quality of separation.

  10. Quantitative characterization of solid epoxy resins using comprehensive two dimensional liquid chromatography coupled with electrospray ionization-time of flight mass spectrometry.

    Science.gov (United States)

    Julka, Samir; Cortes, Hernan; Harfmann, Robert; Bell, Bruce; Schweizer-Theobaldt, Andreas; Pursch, Matthias; Mondello, Luigi; Maynard, Shawn; West, David

    2009-06-01

    A comprehensive multidimensional liquid chromatography system coupled to Electrospray Ionization-Mass Spectrometry (LCxLC-ESI-MS) was developed for detailed characterization and quantitation of solid epoxy resin components. The two orthogonal modes of separation selected were size exclusion chromatography (SEC) in the first dimension and liquid chromatography at critical conditions (LCCC) in the second dimension. Different components present in the solid epoxy resins were separated and quantitated for the first time based on the functional groups and molecular weight heterogeneity. Coupling LCxLC separations with mass spectrometry enabled the identification of components resolved in the two-dimensional space. Several different functional group families of compounds were separated and identified, including epoxy-epoxy and epoxy-alpha-glycol functional oligomers, and their individual molecular weight ranges were determined. Repeatability obtained ranged from 0.5% for the main product to 21% for oligomers at the 0.4% concentration level.

  11. Mid-Infrared Pulse Shaping and Two-Dimensional Spectroscopy of Open Quantum Systems in Liquid Solution

    Science.gov (United States)

    Ross, Matthew R.

    The primary focus of this work is the development of a mid-infrared pulse shaping system. The primary motivation for this system is for two-dimensional infrared (2DIR) spectroscopy, however, the mid-infrared pulse shaper also allows for more sophisticated spectroscopic experiments not previously attempted in the mid-infrared. Moreover, many can be implemented without changes or realignment of the optical setup. Example spectra are presented along with a discussion of capabilities and diagnostics. A second major project presented is 2DIR spectroscopy of iron pentacarbonyl, Fe(CO)5, a small metal carbonyl. This molecule undergoes Berry pseudorotation, a form of fluxtionality. This fast exchange of ligands mixes axial and equatorial modes and occurs on a timescale of picoseconds, too fast for NMR and other methods of measuring chemical structure and isomerization. Ultrafast chemical exchange spectroscopy, a measurement within 2DIR spectroscopy, is capable of resolving the time scales of this motion. We found that this process is affected by the solvent environment, specifically the solvent viscosity in alkanes and hydrogen bonding environments in alcohols. Lastly, a study is presented in which a series of synthetic metalloenzymes with a metal active site are studied by 2DIR spectroscopy. In this case a carbonyl is ligated to a copper-I atom in the active site, which then serves as our spectroscopic probe. We find, unexpectedly, that the shape of the carbonyl vibrational potential, as measured by the anharmonicity, is time-dependent. We attribute this to a geometrical rearrangement and are able to suggest that this effect is dependent on local site structure and dynamics and not significantly affected by electric potential near the peptide.

  12. Heat transfer in the flow of a cold, two-dimensional vertical liquid jet against a hot, horizontal plate

    CERN Document Server

    Shu, Jian-Jun

    2014-01-01

    A cold, thin film of liquid impinging on an isothermal hot, horizontal surface has been investigated. An approximate solution for the velocity and temperature distributions in the flow along the horizontal surface is developed, which exploits the hydrodynamic similarity solution for thin film flow. The approximate solution may provide a valuable basis for assessing flow and heat transfer in more complex settings.

  13. Non-invasive Transdermal Two-dimensional Mapping of Cutaneous Oxygenation with Rapid-drying Liquid Bandage

    Science.gov (United States)

    2014-10-01

    porphyrin protein scaffolds for sensing O2.,” J. Am. Chem. Soc. 132(16), 5582–5583 (2010). 19. C. Wu, B. Bull, K. Christensen, and J. McNeill...transparent, polymeric liquid bandage material, the sensor #217203 - $15.00 USD Received 22 Jul 2014; revised 5 Sep 2014; accepted 5 Sep 2014; published 1

  14. Determination of five antiarrhythmic drugs in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Jouyban, Abolghasem; Sorouraddin, Mohammad Hossein; Farajzadeh, Mir Ali; Somi, Mohammad Hossein; Fazeli-Bakhtiyari, Rana

    2015-03-01

    A fast and sensitive high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection was developed and validated for the simultaneous quantitation of five antiarrhythmic drugs (metoprolol, propranolol, carvedilol, diltiazem, and verapamil) in human plasma samples. It involves dispersive liquid-liquid microextraction (DLLME) of the desired drugs from 660 µL plasma and separation using isocratic elution with UV detection at 200 nm. The complete separation of all analytes was achieved within 7 min. Acetonitrile (as disperser solvent) resulting from the protein precipitation procedure was mixed with 100 µL dichloromethane (as an extraction solvent) and rapidly injected into 5 mL aqueous solution (pH 11.5) containing 1% (w/v), NaCl. After centrifugation, the sedimented phase containing enriched analytes was collected and evaporated to dryness. The residue was re-dissolved in 50 µL de-ionized water (acidified to pH 3) and injected into the HPLC system for analysis. Under the optimal conditions, the enrichment factors and extraction recoveries ranged between 4.4-10.8 and 33-82%, respectively. The suggested method was linear (r(2) ≥0.997) over a dynamic range of 0.02-0.80 µg mL(-1) in plasma. The intra- and inter-days relative standard deviation (RSD%) and relative error (RE%) values of the method were below 20%, which shows good precision and accuracy. Finally, this method was applied to the analysis of real plasma samples obtained from the patients treated with these drugs.

  15. Analysis of drugs of abuse in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Fernández, P; Regenjo, M; Bermejo, A M; Fernández, A M; Lorenzo, R A; Carro, A M

    2015-04-01

    Opioids and cocaine are widely used at present, both for recreational purposes and as drugs of abuse. This raises the need to develop new analytical methods specifically designed for the simultaneous detection of several drugs of abuse in biological samples. In this work, dispersive liquid-liquid microextraction (DLLME) was assessed as a new sample treatment for the simultaneous extraction of morphine (MOR), 6-acetylmorphine (6AM), cocaine (COC), benzoylecgonine (BZE) and methadone (MET) from human plasma. Preliminary assays were done before developing an experimental design based on a Uniform Network Doehlert which allowed the optimum extraction conditions to be identified, namely: a volume of extractant solvent (chloroform) and dispersant solvent (acetonitrile) of 220 µl and 3.2 ml, respectively; 0.2 g of NaCl as a salting-out additive; pH 10.6 and ultrasound stirring for 3.5 min. The resulting extracts were analyzed by high-performance liquid chromatography with photodiode array detection (HPLC-PDA), using an XBridge® RP18 column (250 × 4.6 mm i.d., 5 µm particle size). Calibration graphs were linear over the concentration range 0.1-10 µg ml⁻¹, and detection limits ranged from 13.9 to 28.5 ng ml⁻¹. Precision calculated at three different concentration levels in plasma was included in the range 0.1-6.8% RSD. Recoveries of the five drugs were all higher than 84% on average. Finally the proposed method was successfully applied to 22 plasma samples from heroin, cocaine and/or methadone users, and the most frequently detected drug was benzoylecgonine, followed by methadone, cocaine and morphine.

  16. Preliminary Validation of High Performance Liquid Chromatography Method for Detection of Methyltestosterone Residue in Carp Muscle

    Institute of Scientific and Technical Information of China (English)

    JIANG Jie; LIN Hong; FU Xiaoting; LI Mingming

    2005-01-01

    The use of synthetic anabolic steroid methyltestosterone (MT) as growth promoter is prohibited in China. Validations of analytical methods for MT residue in food and the results obtained have become indispensable. The high performance liquid chromatography (HPLC) method for the detection of MT with liquid-liquid extraction by trichloromethanemethanol in carp muscle tissue was preliminarily validated with reference to the following parameters: recovery (accuracy)at the 1, 5 and 10 mgkg-1 level, between-run and within-run CV values (repeatability, also called relative standard deviation(RSD)) and limit of detection. The recoveries were above 80% and the between-run and within-run CV values below 10%for muscle tissue. The limit of detection was 0.05 mgkg-1.

  17. Analysis of nitroguanidine in Aqueous Solutions by HPLC (High Performance Liquid Chromatography) with electrochemical Detection and Voltammetry

    Science.gov (United States)

    1987-04-01

    The nitroguanidine was analyzed by high performance liquid chromatography (HPLC) with electrochemical detection at a hanging miercury drop electrode...previously reported on the application of solid sorbent collection techniques to the analysis of several explosives in water by high performance liquid chromatography (HPLC

  18. Development of selective comprehensive two-dimensional liquid chromatography with parallel first-dimension sampling and second-dimension separation--application to the quantitative analysis of furanocoumarins in apiaceous vegetables.

    Science.gov (United States)

    Larson, Elliot D; Groskreutz, Stephen R; Harmes, David C; Gibbs-Hall, Ian C; Trudo, Sabrina P; Allen, Robert C; Rutan, Sarah C; Stoll, Dwight R

    2013-05-01

    Various implementations of two-dimensional high-performance liquid chromatography are increasingly being developed and applied to the analysis of complex materials, including those encountered in the analysis of foods, beverages, and nutraceuticals. Previously, we introduced the concept of selective comprehensive two-dimensional liquid chromatography (sLC × LC) as a hybrid between the more conventional, but extreme opposite sampling modes of heartcutting (LC-LC) and fully comprehensive (LC × LC) 2D separation. The sLC × LC approach breaks the link between first dimension ((1)D) sampling time and second dimension ((2)D) analysis time that is faced in LC × LC and allows very rapid (as low as 1 s) sampling of highly efficient (1)D separations, while at the same time allowing efficient (2)D separations on the timescale of tens of seconds. In this paper, we improve upon our previous sLC × LC work by demonstrating the ability to perform the processes of (1)D sampling and (2)D separation in parallel. This significantly improves the flexibility of the technique and allows targeted analysis of analytes that elute close together in time in the (1)D separation. To demonstrate the value of this added capability, we have developed a sLC × LC method using multi-wavelength ultraviolet absorbance detection for the quantitative analysis of six target furanocoumarin compounds in extracts of celery, parsley, and parsnips. We show that (2)D separations of (1)D effluent containing the target compounds of interest reveal the presence of unanticipated interferent peaks that would otherwise compromise the quantitative accuracy of the method. We also demonstrate the application of the chemometric method iterative key set factor analysis with alternating least-squares to sLC × LC to mathematically resolve target compounds that are only slightly separated chromatographically but not sufficiently resolved for accurate quantitation.

  19. High-Performance Liquid Chromatography Determination of Meloxicam and Piroxicam with Ultraviolet Detection

    Directory of Open Access Journals (Sweden)

    Sherry Cox

    2014-01-01

    Full Text Available A simple accurate and sensitive high-performance liquid chromatographic method for the determination of meloxicam and piroxicam concentrations in small volume plasma samples has been developed. Following a liquid extraction using chloroform, samples were separated by reversed-phase high-performance liquid chromatography on an XBridge C18 column (4.6 × 250 mm and quantified using ultraviolet detection at 360 nm. The mobile phase was a mixture of water with glacial acetic acid (pH 3.0 and acetonitrile (50 : 50, with a flow rate of 1.0 mL/min. The standard curve ranged from 5 to 10,000 ng/mL for meloxicam in bearded dragon (Pogona vitticeps plasma and piroxicam in crane (Grus rubicunda plasma. Intra- and interassay variability for meloxicam and piroxicam were less than 10% and the average recovery was greater than 90% for both drugs. This method was developed in bearded dragon and crane plasma and should be applicable to any species, making it useful for those investigators dealing with small sample volumes, particularly when conducting pharmacokinetics studies which require multiple sampling from the same animal.

  20. Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all r...

  1. Screening anti-tumor compounds from Ligusticum wallichii using cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry.

    Science.gov (United States)

    Zhang, Tao; Ding, Yuanyuan; An, Hongli; Feng, Liuxin; Wang, Sicen

    2015-07-14

    Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry was developed. Tyrosine 367 Cysteine-HEK293 cells were used as cell membrane stationary phase. Specificity and reproducibility of the cell membrane chromatography was evaluated using 1-tert-butyl-3-{2-[4-(diethylamino)butylamino]-6-(3,5-dimethoxyphenyl)pyrido[2,3-d]pyrimidin-7-yl}urea, Nimodipine and dexamethasone acetate. Then, anti-tumor components acting on Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 were screened and identified from extracts of Ligusticum wallichii. Components from the extract were retained on the cell membrane chromatographic column. The retained fraction was directly eluted into high-performance liquid chromatography with mass spectrometry system for separation and identification. Finally, Levistolide A was identified as an active component from Ligusticum wallichii extracts. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide-formazan colorimetric assay revealed that Levistolide A inhibits proliferation of overexpressing the mutated receptor cells with dose-dependent manner. Phosphorylation of fibroblast growth factor receptor 4 was also decrease under Levistolide A treatment. Flex dock simulation verified that Levistolide A could bind with the tyrosine kinase domain of fibroblast growth factor receptor 4. Therefore, Levistolide A screened by the cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry can arrest cell growth. In conclusion, the two-dimensional high-performance liquid chromatography method can screen and identify potential anti-tumor ingredients which specifically act on the tyrosine kinase domain of the mutated fibroblast growth factor receptor 4. This article is protected by copyright. All rights reserved.

  2. Computational aspects of the smectization process in liquid crystals: An example study of a perfectly aligned two-dimensional hard-boomerang system

    Science.gov (United States)

    Chrzanowska, Agnieszka

    2017-06-01

    A replica method for calculation of smectic liquid crystal properties within the Onsager theory has been presented and applied to an exemplary case of two-dimensional perfectly aligned needlelike boomerangs. The method allows one to consider the complete influence of the interaction terms in contrast to the Fourier expansion method which uses mostly first or second order terms of expansion. The program based on the replica algorithm is able to calculate a single representative layer as an equivalent set of layers, depending on the size of the considered width of the sample integration interval. It predicts successfully smectic density distributions, energies, and layer thicknesses for different types of layer arrangement—of the antiferroelectric or of the smectic A order type. Specific features of the algorithm performance and influence of the numerical accuracy on the physical properties are presented. Future applications of the replica method to freely rotating molecules are discussed.

  3. Two-dimensional liquid chromatography technique coupled with mass spectrometry analysis to compare the proteomic response to cadmium stress in plants.

    Science.gov (United States)

    Visioli, Giovanna; Marmiroli, Marta; Marmiroli, Nelson

    2010-01-01

    Plants are useful in studies of metal toxicity, because their physiological responses to different metals are correlated with the metal exposure dose and chemical state. Moreover a network of proteins and biochemical cascades that may lead to a controlled homeostasis of metals has been identified in many plant species. This paper focuses on the global protein variations that occur in a Populus nigra spp. clone (Poli) that has an exceptional tolerance to the presence of cadmium. Protein separation was based on a two-dimensional liquid chromatography technique. A subset of 20 out of 126 peaks were identified as being regulated differently under cadmium stress and were fingerprinted by MALDI-TOF. Proteins that were more abundant in the treated samples were located in the chloroplast and in the mitochondrion, suggesting the importance of these organelles in the response and adaptation to metal stress.

  4. Two-Dimensional Liquid Chromatography Technique Coupled with Mass Spectrometry Analysis to Compare the Proteomic Response to Cadmium Stress in Plants

    Directory of Open Access Journals (Sweden)

    Giovanna Visioli

    2010-01-01

    Full Text Available Plants are useful in studies of metal toxicity, because their physiological responses to different metals are correlated with the metal exposure dose and chemical state. Moreover a network of proteins and biochemical cascades that may lead to a controlled homeostasis of metals has been identified in many plant species. This paper focuses on the global protein variations that occur in a Populus nigra spp. clone (Poli that has an exceptional tolerance to the presence of cadmium. Protein separation was based on a two-dimensional liquid chromatography technique. A subset of 20 out of 126 peaks were identified as being regulated differently under cadmium stress and were fingerprinted by MALDI-TOF. Proteins that were more abundant in the treated samples were located in the chloroplast and in the mitochondrion, suggesting the importance of these organelles in the response and adaptation to metal stress.

  5. Quantification of Quercetin and Rutin from Benincasa hispida Seeds and Carissa Congesta Roots by High-performance Thin Layer Chromatography and High-performance Liquid Chromatography.

    Science.gov (United States)

    Doshi, Gaurav Mahesh; Une, Hemant Devidas

    2016-01-01

    In Indian Ayurvedic system, Benincasa hispida (BH) and Carissa congesta (CC) are well-known plants used for major and minor ailments. BH has been regarded as Kushmanda, whereas CC has been used in immune-related disorders of the human system. Quercetin and rutin identified from the vast plethora of plant extracts have proved to possess ethnopharmacological relevance. In present studies, we have determined quercetin and rutin in terms of percentage in BH seeds and CC roots by high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC). After extraction and phytochemical screening, the extracts were subjected to quantification for the presence of quercetin and rutin by HPTLC and HPLC. HPTLC showed quercetin as 44.60, 27.13% and rutin as 32.00, 36.31% w/w, whereas HPLC revealed quercetin as 34.00, 35.00% and rutin as 21.99, 45.03% w/v in BH and CC extracts, respectively. The BH and CC extracts have elucidated peaks that were corresponding with standard peaks on undertaking chromatographic studies. Quercetin and rutin are isolated from BH seeds and CC roots by High Performance. Thin Layer Chromatography and High Performance Liquid Chromatography. HPTLC revealed presence of quercetin as 44.60, 27.13 % and rutin as 32.00, 36.31 % w/w. HPLC revealed presence of quercetin as 34.00, 35.00 % and rutin as 21.99, 45.03 % w/v. Abbreviation Used: HPTLC: High Performance Thin Layer Chromatography; HPLC: High Pressure Liquid Chromatography, UV: Ultraviolet, CC: Carissa congesta, BH: Benincasa hispida.

  6. Possibility of a two-dimensional spin liquid in CePdAl induced by partial geometric frustration?

    Energy Technology Data Exchange (ETDEWEB)

    Fritsch, V. [Universitaet Augsburg, Institut fuer Physik, Experimentalphysik VI (Germany); Karlsruher Institut fuer Technologie (Germany); Grube, K.; Kittler, W.; Taubenheim, C.; Loehneysen, H. von [Karlsruher Institut fuer Technologie (Germany); Huesges, Z.; Lucas, S.; Stockert, O. [Max-Planck-Institut fuer chemische Physik fester Stoffe, Dresden (Germany); Green, E. [Hochfeldzentrum Dresden-Rossendorf (Germany)

    2015-07-01

    CePdAl crystallizes in the hexagonal ZrNiAl structure, where the magnetic ions form a distorted kagome lattice. At T{sub N} = 2.7 K the onset of antiferromagnetic (AF) order is observed. Neutron scattering experiments revealed a partial frustration in the distorted kagome planes of this structure: two-thirds of the Ce moments form ferromagnetic chains, which are antiferromagnetically coupled, the remaining third do not participate in any long-range order. Along the c-axis the magnetic moments exhibit an amplitude modulation. Accordingly, the kagome planes are stacked on top of each other, resulting in corrugated AF planes parallel to the c-axis formed by the ordered magnetic moments, which are separated by the frustrated moments. It is an intriguing and yet unresolved question if this third of frustrated moments forms a spin liquid state in CePdAl. Based on measurements of specific heat, thermal expansion, magnetization and electrical resistivity we want to discuss this possibility.

  7. On-line radiochemical assay for monoamine oxidase utilizing high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Nissinen, E.; Linko-Loeppoenen SMae; Maennistoe P4

    1984-12-01

    A fast and sensitive assay for the determination of monoamine oxidase activity was developed. The method is based on the separation and quantitation of /sup 14/C-labeled assay products by high-performance liquid chromatography, which is interfaced directly into a flow-through radioactivity detector. This allows on-line quantitation of the radioactive compounds with picomole sensitivity. The method makes possible the complete separation and detection of the deaminated products of monoamine oxidase A and B substrates benzylamine and 5-hydroxytryptamine, respectively. This assay has been applied to the measurement of monoamine oxidase A and B activities in rat brain.

  8. Determination of 1-hydroxypyrene in human urine by high-performance liquid chromatography

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Poulsen, O M; Christensen, J M

    1993-01-01

    A high-performance liquid chromatography (HPLC)/fluorescence method for quantitative analysis of 1-hydroxypyrene in urine was developed. The method validation analysis showed the method to be in analytical control. No significant systematical errors could be demonstrated. The entire run time...... of chromatography was 10 min using isocratic elution (acetonitrile-water, 70:30), and the retention time for 1-hydroxypyrene was 3.5 min. The short run time in combination with the low limit detection (1.37 nmol/L) makes the method potentially applicable for surveillance of pyrene exposure in work environments...

  9. Determination of Constituents in Hair Dyes by Reversed-phase High-Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A reversed-phase high-performance liquid chromatographic method for the separation and quantitation of 1,4-phenylenediamine, 4-aminophenol, 3-aminophenol, 1,3-benzendiol and 2,6-phenylenediamine in hair dyes was developed. The separation was carried out on a μ-Bondapak C18 column with methanol-water containing 0.1% triethylamine and 0.02 mol/L NH4Ac (pH=5.20) (10:90, vol./vol.) as the mobile phase. Two real samples were analyzed.

  10. Determination of enantiomeric impurity of etomidate by high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective To determine enantiomeric impurity of etomidate using high performance liquid chromatography. Methods (R)-etomidate and (S)-etomidate were separated on a CHIRALPAK AD-H column. The mobile phase consisted of 20∶80(v/v) isopropanol-n-hexane. The flow rate of the mobile phase was 0.5mL/min. The detected wavelength was 242nm. Results (R)-etomidate and (S)-etomidate could be separated completely under these conditions. The precision of (R)-etomidate was 1.57% (n=3). The limit of detection of (R)-etomid...

  11. Anomalous properties of flavonoids in reversed phase high performance liquid chromatography

    Science.gov (United States)

    Zenkevich, I. G.; Gushchina, S. V.

    2011-09-01

    It is shown through reversed phase high performance liquid chromatography that a characteristic feature of such abundant natural flavonoids as flavon-3-ols is an anomalously strong antibate dependence of their retention indices ( RI) on the organic solvent concentration ( C) in the eluent, dRI/ dC < 0. In order to interpret this anomaly, the specific optical rotation values [α]{D/20} of natural (+)-(2 R,3 R)-dihydroquercetin in different solvents are compared, confirming the reverse formation of hydrated flavonoids in aqueous solutions.

  12. Study of Saiga Horn Using High-Performance Liquid Chromatography with Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Kateřina Mikulíková

    2012-01-01

    Full Text Available The saiga horns have been investigated the using of modern analytic methods. High-performance liquid chromatography (HPLC with mass-spectrometric (MS and MS/MS detection and polyacrylamide gel electrophoresis (PAGE were used. It could be concluded that basic proteins of the saiga horns are keratins and collagen. The basic representation protein in all samples is keratin type I microfibrillar (from sheep, keratin type II microfibrillar (from sheep, collagen type I (α1 (from bovine and collagen type I (α2 (from bovine. Free amino acids we determined in all samples are nontreated by enzyme.

  13. Quantitative high-performance liquid chromatographic determination of delta 4-3-ketosteroids in adrenocortical extracts.

    Science.gov (United States)

    Ballerini, R; Chinol, M; Ghelardoni, M

    1980-05-30

    A high-performance liquid chromatographic method is described for the determination of seven steroids in adrenocortical extracts showing a delta 4-3-ketonic conjugated system. The seven steroids (cortisol, cortisone, 11-dehydrocorticosterone, corticosterone, 11-deoxycortisol, aldosterone and 11-deoxycorticosterone) were separated with a chloroform-methanol gradient on a 5-micron silica column and with a water-acetonitrile gradient on a 10-micron RP-8 column. Effluents were monitored by UV absorption at 242 nm. Quantitative analysis was performed by comparing peak areas, which are proportional to the amounts of the individual substances (external standard method). The method is rapid, sensitive, easy to perform and reproducible.

  14. Determination of cortisol and cortisone in urine using high-performance liquid chromatography with UV detection.

    Science.gov (United States)

    Jenner, D A; Richards, J

    1985-01-01

    The application of reversed-phase gradient high-performance liquid chromatography with UV detection to the determination of cortisol and cortisone in 24-h urine samples is described. The method employs Sep-pak C18 cartridges for the part-purification and concentration of the corticosteroids, with sample enrichment at the head of an HPLC pre-column and separation using water/acetonitrile gradient. The internal standard is 6alpha-methylprednisolone. Measurement of both cortisone and cortisol provides further information on adrenocortical function. 24-hour excretion rate data from normal subjects are reported.

  15. Determination of rhoifolin and daidzin in human plasma by high-performance liquid chromatography.

    Science.gov (United States)

    Ishii, K; Urano, S; Furuta, T; Kasuya, Y

    1994-05-13

    A method for determining flavonoids in human plasma is presented for application to pharmacokinetic studies of two flavonoids, rhoifolin and daidzin. Isocratic reversed-phase high-performance liquid chromatography (HPLC) was used with genistin as an internal standard and solid-phase extraction using a Sep-Pak C18 cartridge. The mobile phases were acetonitrile-0.1 M ammonium acetate solution (20:80, v/v) for rhoifolin and methanol-0.1 M ammonium acetate solution (33:67, v/v) for daidzin. The detection limits on-column were 2 ng for rhoifolin and 0.5 ng for daidzin.

  16. Rapid determination of succinylcholine in human plasma by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Lagerwerf, A J; Vanlinthout, L E; Vree, T B

    1991-10-04

    A high-performance liquid chromatographic method with fluorometric detection has been developed for the determination of succinylcholine in human plasma. Succinylcholine shows fluorescence at 282 nm with an excitation at 257 nm. The assay is sensitive, reproducible and linear for concentrations ranging from 100 ng/ml to 100 micrograms/ml of succinylcholine. In a pilot study the plasma concentration-time curve showed a triphasic elimination, with half-lives of 0.4, 1.2 and 8 min, respectively. In a clinical setting, drugs commonly administered during anaesthesia did not interfere with the assay. This method provides a simple and time-saving alternative to existing methods.

  17. Determination of contents of 10-Hydroxycamptothecin in Camptotheca acuminata by high-performance liquid chromatogram

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The determination method of 10-hydroxycamptothecin in Camptotheca acuminata fruits by high-performance liquid chromatogram (HPLC) was studied. The HPLC analysis was performed on a HIQ sil C18(4.6×250 mm) column with mobile phase of acetonitrile-water (3:7, V:V), flow rate 1 mL@(min-1 and UV detective wavelength 266 nm. Extracting 10-hydroxycamptothecin by ultrasonic method from fruits of C. acuminata to prepare samples for analysis was systematically discussed. The optimal extraction condition was carried out by 60% alcohol solution at 60℃ for 50 minutes.

  18. Fluorimetric assay for ornithine decarboxylase by high-performance liquid chromatography.

    Science.gov (United States)

    Haraguchi, K; Kai, M; Kohashi, K; Ohkura, Y

    1980-12-05

    A highly sensitive method for the assay of ornithine decarboxylase in sample solutions prepared from rat tissue homogenate is described which employs high-performance liquid chromatography with fluorescence detection. Putrescine formed from ornithine under the optimal conditions for the enzyme reaction is treated by Cellex P column chromatography for clean-up and converted into the fluorescamine derivative in the presence of cupric ion which inhibits the reaction of interfering amines with fluorescamine. The derivative is separated by reversed-phase chromatography on LiChrosorb RP-18 with linear gradient elution. The lower limit of detection for putrescine formed enzymatically is 5 pmol.

  19. Detection of cheese whey and caseinomacropeptide in fermented milk beverages using high performance liquid chromatography

    OpenAIRE

    E.H.P. Andrade; M.R. Souza; Fonseca,L.M.; C.F.A.M. Penna; M.M.O.P. Cerqueira; T. Roza; Seridan,B.; M.F.S. Resende; Pinto, F. A.; C.N.B.C. Villanoeva; Leite,M.O.

    2014-01-01

    Cheese whey level and caseinomacropeptide (CMP) index of fermented milk beverages added with four levels of cheese whey (0, 10, 20, and 40%) and stored at 8-10oC for 0, 7, 14 and 21 days were determined by high performance liquid chromatography-gel filtration (HPLC-GF). Additionally, the interference of the starter culture and the storage time on the detection of cheese whey and CMP were investigated. Refrigerated storage up to 21 days did not affect (P>0.05) cheese whey and CMP amounts in mi...

  20. Simultaneous determination of pseudoephedrine hydrochloride and cetrizine hydrochloride by reverse phase high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Nalini C

    2006-01-01

    Full Text Available A reversed phase high performance liquid chromatographic method has been developed using Shimadzu HPLC-VP series, LC-10 ATV pump, SPD10 AVP and C8 column, for simultaneous determination of pseudoephedrine hydrochloride and cetrizine hydrochloride in three marketed tablet formulations (extended release. The mobile phase consists of phosphate buffer of pH 7.0 and acetonitrile HPLC grade in the ratio of 1:1. The flow rate was maintained at 1 ml/min and the ultraviolet detection was done at 242 nm, which is the isosbestic point. Linearity coefficients, assay values, recovery studies and repeatability studies showed that the method is accurate and precise.

  1. Determination of nadolol in serum by high-performance liquid chromatography with fluorimetric detection.

    Science.gov (United States)

    Noguchi, H; Yoshida, K; Murano, M; Naruto, S

    1992-01-17

    A sensitive high-performance liquid chromatographic method for a routine assay of nadolol in serum is described. Serum samples spiked with atenolol (internal standard) were extracted with diethyl ether. After centrifugation, the organic layer was evaporated to dryness. The residue was redissolved in the mobile phase and injected onto an octadecyl silica column (150 mm x 4.6 mm I.D.). The mobile phase was 0.05 M ammonium acetate (pH 4.5)-acetonitrile (85:15, v/v). Fluorometric detection (excitation 230 nm, emission 300 nm) was used. The minimum detectable level of nadolol in serum was 1 ng/ml.

  2. A new method for high-performance liquid chromatographic determination of drotaverine in plasma.

    Science.gov (United States)

    Mezei, J; Küttel, S; Szentmiklósi, P; Marton, S; Rácz, I

    1984-10-01

    A sensitive, specific high-performance liquid chromatographic procedure was developed for the determination of plasma drotaverine levels. Basic plasma samples were adjusted to pH 1.5 and extracted with chloroform. HPLC [n-heptane-dichloromethane-diethylamine (50:25:2)] on a microporous silica column, with a variable-wavelength UV detector set at 302 nm allowed the measurement of drotaverine at the 50-ng/mL level. The utility of this method for determination of drotaverine in dog and rat plasma was demonstrated.

  3. Separation of polyamines, conjugated to DNA, by reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Mateos, J L; Reyes, A; Vicente, C; Legaz, M E

    2000-02-18

    Genomic DNA was isolated from the lichen Evernia prunastri in order to analyze by high-performance liquid chromatography the occurrence of polyamines conjugated to the macromolecule. The acid-insoluble (PH) fraction of this DNA contained mainly conjugated spermidine, although small amounts of free putrescine and spermidine were also present. The PH fraction of DNA also contained conjugated evernic acid, the main phenol produced by this lichen species. Conjugation of polyamines to calf thymus DNA was carried out under in vitro conditions. Conjugation was to spermidine and mainly to spermine and produced DNA compactation. Evernic acid enhanced the action of polyamines in order to produce DNA aggregation.

  4. Studies on the Fingerprint of Yubaizhi by High-Performance Liquid Chromato Graphy

    Institute of Scientific and Technical Information of China (English)

    YU Yu-hong; SUN Yan-ke; LI Xue-chun; DAI Rong-ji; MENG Wei-wei; DENG Yu-lin

    2008-01-01

    The investigation of fingerprint of Yubaizhi was performed by high-performance liquid chromatography (HPLC). Chromatographic conditions were: the mobile phase was the mixture of acetonitrile-water (43:57, v/v); the flow rate was 1mL/min; the column temperature was 40℃; the detection wavelength was 254nm. The stability, precision and reproducibility were performed according to "Specification of Fingerprint of Injection of Chinese Traditional Medicine (temporarily)" regulated by State Food and Drug Administration(SFDA). The HPLC fingerprints of Yubaizhi from various locations were well constant.

  5. Proteomic analysis of prolactinoma cells by immuno-laser capture microdissection combined with online two-dimensional nano-scale liquid chromatography/mass spectrometry

    Directory of Open Access Journals (Sweden)

    Chen Luping

    2010-01-01

    Full Text Available Abstract Background Pituitary adenomas, the third most common intracranial tumor, comprise nearly 16.7% of intracranial neoplasm and 25%-44% of pituitary adenomas are prolactinomas. Prolactinoma represents a complex heterogeneous mixture of cells including prolactin (PRL, endothelial cells, fibroblasts, and other stromal cells, making it difficult to dissect the molecular and cellular mechanisms of prolactin cells in pituitary tumorigenesis through high-throughout-omics analysis. Our newly developed immuno-laser capture microdissection (LCM method would permit rapid and reliable procurement of prolactin cells from this heterogeneous tissue. Thus, prolactin cell specific molecular events involved in pituitary tumorigenesis and cell signaling can be approached by proteomic analysis. Results Proteins from immuno-LCM captured prolactin cells were digested; resulting peptides were separated by two dimensional-nanoscale liquid chromatography (2D-nanoLC/MS and characterized by tandem mass spectrometry. All MS/MS spectrums were analyzed by SEQUEST against the human International Protein Index database and a specific prolactinoma proteome consisting of 2243 proteins was identified. This collection of identified proteins by far represents the largest and the most comprehensive database of proteome for prolactinoma. Category analysis of the proteome revealed a widely unbiased access to various proteins with diverse functional characteristics. Conclusions This manuscript described a more comprehensive proteomic profile of prolactinomas compared to other previous published reports. Thanks to the application of immuno-LCM combined with online two-dimensional nano-scale liquid chromatography here permitted identification of more proteins and, to our best knowledge, generated the largest prolactinoma proteome. This enlarged proteome would contribute significantly to further understanding of prolactinoma tumorigenesis which is crucial to the management of

  6. Rapid determination of six carcinogenic primary aromatic amines in mainstream cigarette smoke by two-dimensional online solid phase extraction combined with liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Bie, Zhenying; Lu, Wei; Zhu, You; Chen, Yusong; Ren, Hubo; Ji, Lishun

    2017-01-27

    A fully automated, rapid, and reliable method for simultaneous determination of six carcinogenic primary aromatic amines (AAs), including o-toluidine (o-TOL), 2, 6-dimethylaniline (2, 6-DMA), o-anisidine (o-ASD), 1-naphthylamine (1-ANP), 2-naphthylamine (2-ANP), and 4-aminobiphenyl (4-ABP), in mainstream cigarette smoke was established. The proposed method was based on two-dimensional online solid phase extraction combined with liquid chromatography tandem mass spectrometry (SPE/LC-MS/MS). The particulate phase of the mainstream cigarette smoke was collected on a Cambridge filter pad and pretreated via ultrasonic extraction with 2% formic acid (FA), while the gas phase was trapped by 2% FA without pretreatment for determination. The two-dimensional online SPE comprised of two cartridges with different absorption characteristics was applied for sample pretreatment. Analysis was performed by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) under multiple reaction monitoring mode. Each sample required about 0.5h for solid phase extraction and analysis. The limit of detections (LODs) for six AAs ranged from 0.04 to 0.58ng/cig and recoveries were within 84.5%-122.9%. The relative standard deviations of intra- and inter-day tests for 3R4F reference cigarette were less than 6% and 7%, respectively, while no more than 7% and 8% separately for a type of Virginia cigarette. The proposed method enabled minimum sample pretreatment, full automation, and high throughput with high selectivity, sensitivity, and accuracy. As a part of the validation procedure, fifteen brands of cigarettes were tested by the designed method. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Preparation and evaluation of surface-bonded tricationic ionic liquid silica as stationary phases for high-performance liquid chromatography.

    Science.gov (United States)

    Qiao, Lizhen; Shi, Xianzhe; Lu, Xin; Xu, Guowang

    2015-05-29

    Two tricationic ionic liquids were prepared and then bonded onto the surface of supporting silica materials through "thiol-ene" click chemistry as new stationary phases for high-performance liquid chromatography. The obtained columns of tricationic ionic liquids were evaluated respectively in the reversed-phase liquid chromatography (RPLC) mode and hydrophilic interaction liquid chromatography (HILIC) mode, and possess ideal column efficiency of 80,000 plates/m in the RPLC mode with naphthalene as the test solute. The tricationic ionic liquid stationary phases exhibit good hydrophobic and shape selectivity to hydrophobic compounds, and RPLC retention behavior with multiple interactions. In the HILIC mode, the retention and selectivity were evaluated through the efficient separation of nucleosides and bases as well as flavonoids, and the typical HILIC retention behavior was demonstrated by investigating retention changes of hydrophilic solutes with water volume fraction in mobile phase. The results show that the tricationic ionic liquid columns possess great prospect for applications in analysis of hydrophobic and hydrophilic samples.

  8. Gold nanoparticle decorated graphene oxide/silica composite stationary phase for high-performance liquid chromatography.

    Science.gov (United States)

    Liang, Xiaojing; Wang, Xusheng; Ren, Haixia; Jiang, Shengxiang; Wang, Licheng; Liu, Shujuan

    2014-06-01

    In the initial phase of this study, graphene oxide (GO)/silica was fabricated by assembling GO onto the silica particles, and then gold nanoparticles (GNPs) were used to modify the GO/silica to prepare a novel stationary phase for high-performance liquid chromatography. The new stationary phase could be used in both reversed-phase chromatography and hydrophilic interaction liquid chromatography modes. Good separations of alkylbenzenes, isomerides, amino acids, nucleosides, and nucleobases were achieved in both modes. Compared with the GO/silica phase and GNPs/silica phase, it is found that except for hydrophilicity, large π-electron systems, hydrophobicity, and coordination functions, this new stationary phase also exhibited special separation performance due to the combination of 2D GO with zero-dimensional GNPs.

  9. Fractionation of Gibberellins in plant extracts by reverse phase high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Jones, M.G.; Metzger, J.D.; Zeevaart, J.A.D.

    1980-02-01

    In studies on endogenous plant gibberellins (GAs), reverse phase (Bondapak C/sub 18/) high performance liquid chromatography (HPLC) has proved to be a useful method for the fractionation of plant extracts. The behavior of 18 authentic GAs in such a chromatographic system is described. The main factors determining chromatographic behavior are the degree and the position of hydroxylation of the GA. As an illustration of the use of reverse phase HPLC, the endogeneous GAs of immature seeds of Pharbitis nil L., strain Violet, were reinvestigated. The presence of gibberellins A/sub 3/, A/sub 5/, A/sub 17/, A/sub 20/, and A/sub 29/ was confirmed by gas-liquid chromatography-mass spectrometry. In addition, two other GAs, A/sub 19/ and A/sub 44/, were also identified in extracts of this material.

  10. High-performance liquid-catalyst fuel cell for direct biomass-into-electricity conversion.

    Science.gov (United States)

    Liu, Wei; Mu, Wei; Deng, Yulin

    2014-12-01

    Herein, we report high-performance fuel cells that are catalyzed solely by polyoxometalate (POM) solution without any solid metal or metal oxide. The novel design of the liquid-catalyst fuel cells (LCFC) changes the traditional gas-solid-surface heterogeneous reactions to liquid-catalysis reactions. With this design, raw biomasses, such as cellulose, starch, and even grass or wood powders can be directly converted into electricity. The power densities of the fuel cell with switchgrass (dry powder) and bush allamanda (freshly collected) are 44 mW cm(-2) and 51 mW cm(-2) respectively. For the cellulose-based biomass fuel cell, the power density is almost 3000 times higher than that of cellulose-based microbial fuel cells. Unlike noble-metal catalysts, POMs are tolerant to most organic and inorganic contaminants. Therefore, almost any raw biomass can be used directly to produce electricity without prior purification.

  11. Purification of saponins from leaves of Panax notoginseng using preparative two-dimensional reversed-phase liquid chromatography/hydrophilic interaction chromatography.

    Science.gov (United States)

    Guo, Xiujie; Zhang, Xiuli; Feng, Jiatao; Guo, Zhimou; Xiao, Yuansheng; Liang, Xinmiao

    2013-04-01

    Saponins are widely distributed in the plant kingdom and have been shown to be active components of many medicinal herbs. In this study, a two-dimensional purification method based on reversed-phase liquid chromatography coupled with hydrophilic interaction liquid chromatography was successfully applied to purify saponins from leaves of Panax notoginseng. Nine saponin reference standards were used to test the separation modes and columns. The standards could not be resolved using C18 columns owing to their limited polar selectivity. However, they were completely separated on a XAmide column in hydrophilic interaction liquid chromatography mode, including two pairs of standards that were coeluted on a C18 column. The elution order of the standards on the two columns was sufficiently different, with a correlation coefficient between retention times on the C18 and XAmide columns of 0.0126, indicating good column orthogonality. Therefore, the first-dimension preparation was performed on a C18 column, followed by a XAmide column that was used to separate the fractions in the second dimension. Fifty-four fractions were prepared in the first dimension, with 25 fractions rich in saponins. Eight saponins, including two pairs of isomeric saponins and one new saponin, were isolated and identified from three representative fractions. This procedure was shown to be an effective approach for the preparative isolation and purification of saponins from leaves of P. notoginseng. Moreover, this method could possibly be employed in the purification of low-content and novel active saponins from natural products.

  12. Characterization of synthetic dyes by comprehensive two-dimensional liquid chromatography combining ion-exchange chromatography and fast ion-pair reversed-phase chromatography.

    Science.gov (United States)

    Pirok, Bob W J; Knip, Jitske; van Bommel, Maarten R; Schoenmakers, Peter J

    2016-03-04

    In the late 19th century, newly invented synthetic dyes rapidly replaced the natural dyes on the market. The characterization of mixtures of these so-called early synthetic dyes is complicated through the occurrence of many impurities and degradation products. Conventional one-dimensional liquid chromatography does not suffice to obtain fingerprints with sufficient resolution and baseline integrity. Comprehensive two-dimensional liquid chromatography (LC×LC) is employed in this study, with ion-exchange chromatography in the first dimension and fast ion-pair liquid chromatography in the second. Retention in the first dimension is largely determined by the number of charges, while the selection of a small ion-pair reagent (tetramethylammonium hydroxide) in the second dimension causes retention to be largely determined by the molecular structure of the dye. As a result, there is a high degree of orthogonality of the two dimensions, similar to the values typically encountered in GC×GC. The proposed LC×LC method shows a theroretical peak capacity of about 2000 in an analysis time of about three hours. Clear, informative fingerprints are obtained that open a way to a more efficient characterization of dyes used in objects of cultural heritage.

  13. An electrospray ionization-ion mobility spectrometer as detector for high- performance liquid chromatography.

    Science.gov (United States)

    Zühlke, Martin; Riebe, Daniel; Beitz, Toralf; Löhmannsröben, Hans-Gerd; Zenichowski, Karl; Diener, Marc; Linscheid, Michael W

    2015-01-01

    The application of electrospray ionization (ESI) ion mobility (IM) spectrometry on the detection end of a high-performance liquid chromatograph has been a subject of study for some time. So far, this method has been limited to low flow rates or has required splitting of the liquid flow. This work presents a novel concept of an ESI source facilitating the stable operation of the spectrometer at flow rates between 10 μL mn(-1) and 1500 μL min(-1) without flow splitting, advancing the T-cylinder design developed by Kurnin and co-workers. Flow rates eight times faster than previously reported were achieved because of a more efficient dispersion of the liquid at increased electrospray voltages combined with nebulization by a sheath gas. Imaging revealed the spray operation to be in a rotationally symmetric multijet mode. The novel ESI-IM spectrometer tolerates high water contents (≤90%) and electrolyte concentrations up to 10mM, meeting another condition required of high-performance liquid chromatography (HPLC) detectors. Limits of detection of 50 nM for promazine in the positive mode and 1 μM for 1,3-dinitrobenzene in the negative mode were established. Three mixtures of reduced complexity (five surfactants, four neuroleptics, and two isomers) were separated in the millisecond regime in stand-alone operation of the spectrometer. Separations of two more complex mixtures (five neuroleptics and 13 pesticides) demonstrate the application of the spectrometer as an HPLC detector. The examples illustrate the advantages of the spectrometer over the established diode array detector, in terms of additional IM separation of substances not fully separated in the retention time domain as well as identification of substances based on their characteristic Ims.

  14. Feeding of liquid silicon for high performance multicrystalline silicon with increased ingot height and homogenized resistivity

    Science.gov (United States)

    Krenckel, Patricia; Riepe, Stephan; Schindler, Florian; Strauch, Theresa

    2017-04-01

    Feeding of liquid silicon during the directional solidification process is a promising opportunity for cost reduction by increased throughput and improved material homogeneity due to constant resistivity over ingot height. In this work, a liquid feeding apparatus was developed for an industrial type directional solidification furnace. One n-type G2 sized High Performance multicrystalline ingot with liquid feeding of additional 14 kg of undoped silicon feedstock was crystallized. The resistivity was kept within a range of ±0.1 Ω cm of the target resistivity during the feeding sequence. A smaller mean grain area growth was observed during feeding, whereas the area fraction of recombination active dislocation structures was as low as in a reference ingot. Increased interstitial oxygen and substitutional carbon concentrations were measured for the ingot with liquid feeding. The measured mean bulk lifetime of 190 μs for passivated wafers in the feeding sequence can probably be increased by further pre-melting crucible improvements. For this laboratory experiment, energy reductions of 2% per wafer and time savings of 16% per wafer were realized.

  15. Simultaneous determination of airborne carbamates in workplace by high performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Li, Hong-Ping; Li, Jen-Hou; Li, Gwo-Chen; Jen, Jen-Fon

    2004-06-17

    A high performance liquid chromatography with fluorescence (HPLC-F) detector was examined to simultaneous determination of airborne carbamates in the workplace of manufactory. The OVS-2 air sampling tube filled with glass fiber filter or quartz fiber and combined filter/XAD-2 were evaluated to collect nine commonly used carbamates (Carbofuran, Isoprocarb, Methomyl, Metolcarb, Thiodicarb, Carbaryl, Oxamyl, Methiocarb, and Prpoxur) from the air of manufactory in high humidity country. After being extracted with acetonitrile from sampling tubes, the carbamates were determined by high performance liquid chromatography with fluorescence detection posterior to on-line derivatization. The collection of carbamates and the recovery of extraction from glass wool fiber in several concentration levels, and from quartz filter were evaluated. The storage stability of carbamates was also tested. Results indicated that the HPLC-fluorescence method offers satisfactory resolution and sensitivity in carbamate analysis. With the glass fiber filter and combined filter/XAD-2, the Carbofuran, Isoprocarb, Methomyl, Metolcarb, and Thiodicarb were stable for a 28-day storage test, Carbaryl and Oxamyl for 14 days, and Methiocarb and Prpoxur for 7 days. All of these pesticides were with detection limit of 3mugm(-3). It is suited for environmental monitoring. The airborne carbamates in different areas of the manufactory were measured.

  16. Hb A1c Separation by High Performance Liquid Chromatography in Hemoglobinopathies

    Science.gov (United States)

    Chandrashekar, Vani

    2016-01-01

    Hb A1c measurement is subject to interference by hemoglobin traits and this is dependent on the method used for determination. In this paper we studied the difference between Hb A1c measured by HPLC in hemoglobin traits and normal chromatograms. We also studied the correlation of Hb A1c with age. Hemoglobin analysis was carried out by high performance liquid chromatography. Spearman's rank correlation was used to study correlation between A1c levels and age. Mann-Whitney U test was used to study the difference in Hb A1c between patients with normal hemoglobin and hemoglobin traits. A total of 431 patients were studied. There was positive correlation with age in patients with normal chromatograms only. No correlation was seen in Hb E trait or beta thalassemia trait. No significant difference in Hb A1c of patients with normal chromatograms and patients with hemoglobin traits was seen. There is no interference by abnormal hemoglobin in the detection of A1c by high performance liquid chromatography. This method cannot be used for detection of A1c in compound heterozygous and homozygous disorders. PMID:26989559

  17. Hb A1c Separation by High Performance Liquid Chromatography in Hemoglobinopathies

    Directory of Open Access Journals (Sweden)

    Vani Chandrashekar

    2016-01-01

    Full Text Available Hb A1c measurement is subject to interference by hemoglobin traits and this is dependent on the method used for determination. In this paper we studied the difference between Hb A1c measured by HPLC in hemoglobin traits and normal chromatograms. We also studied the correlation of Hb A1c with age. Hemoglobin analysis was carried out by high performance liquid chromatography. Spearman’s rank correlation was used to study correlation between A1c levels and age. Mann-Whitney U test was used to study the difference in Hb A1c between patients with normal hemoglobin and hemoglobin traits. A total of 431 patients were studied. There was positive correlation with age in patients with normal chromatograms only. No correlation was seen in Hb E trait or beta thalassemia trait. No significant difference in Hb A1c of patients with normal chromatograms and patients with hemoglobin traits was seen. There is no interference by abnormal hemoglobin in the detection of A1c by high performance liquid chromatography. This method cannot be used for detection of A1c in compound heterozygous and homozygous disorders.

  18. Determination of Niacinamide in Lotions and Creams Using Liquid-Liquid Extraction and High-Performance Liquid Chromatography

    Science.gov (United States)

    Usher, Karyn M.; Simmons, Carolyn R.; Keating, Daniel W.; Rossi, Henry F., III

    2015-01-01

    Chemical separations are an important part of an undergraduate chemistry curriculum. Sophomore students often get experience with liquid-liquid extraction in organic chemistry classes, but liquid-liquid extraction is not as often introduced as a quantitative sample preparation method in honors general chemistry or quantitative analysis classes.…

  19. Determination of Niacinamide in Lotions and Creams Using Liquid-Liquid Extraction and High-Performance Liquid Chromatography

    Science.gov (United States)

    Usher, Karyn M.; Simmons, Carolyn R.; Keating, Daniel W.; Rossi, Henry F., III

    2015-01-01

    Chemical separations are an important part of an undergraduate chemistry curriculum. Sophomore students often get experience with liquid-liquid extraction in organic chemistry classes, but liquid-liquid extraction is not as often introduced as a quantitative sample preparation method in honors general chemistry or quantitative analysis classes.…

  20. Ultrasound-assisted ionic liquid-based homogeneous liquid-liquid microextraction high-performance liquid chromatography for determination of tanshinones in Salvia miltiorrhiza Bge. root.

    Science.gov (United States)

    Wang, Zhibing; Cao, Bocheng; Yu, Aimin; Zhang, Hanqi; Qiu, Fangping

    2015-02-01

    The ultrasound-assisted ionic liquid-based homogeneous liquid-liquid microextraction has been developed and applied to the extraction of four tanshinones, including dihydrotanshinone, tanshinone I, cryptotanshinone and tanshinone IIA in Salvia miltiorrhiza Bge. root. High performance liquid chromatography was applied to the separation and determination of the analytes. The ionic liquid was used as extraction solvent and target analytes were extracted with help of ultrasound. Then, ion-pairing agent was added into the sample solution, which resulted in the formation of water-insoluble ionic liquid in the solution. The phase separation was performed by centrifugation. The extraction, concentration and purification of target analytes were performed simultaneously. The experimental parameters, including type and volume of ionic liquid, sample amount, the size of sample particle, pH value of extraction medium, extraction temperature, extraction time, amount of ion-pairing agent and centrifuging time, were investigated and optimized. The calibration curves showed good linear relationship (r>0.9997). The limits of detection and quantification were in the range of 0.052-0.093 and 0.17-0.31 μg mL(-1), respectively. The recoveries were between 70.45% and 94.23% with relative standard deviations lower than 5.31%. The present method is free of volatile organic solvents, and represents lower expenditures of sample, extraction time and solvent, compared with UAE and HRE. There was no obvious difference in the extraction yields of active constitutions obtained by the three extraction methods.

  1. Application of fractionized sampling and stacking for construction of an interface for online heart-cutting two-dimensional liquid chromatography.

    Science.gov (United States)

    Ji, Baocheng; Xia, Bing; Liu, Jie; Gao, Yuanji; Ding, Lisheng; Zhou, Yan

    2016-09-30

    In this study, an efficient interface, based on a fractionized sampling and stacking (FSS) strategy, was developed for online heart-cutting two-dimensional liquid chromatography (2D LC). This interface consisted of a two-position 4-port valve, a two-position 6-port valve and a two-position 10-port valve equipped with two 450-μL stainless steel loops. Hydrophilic interaction chromatography (HILIC) and reversed phase liquid chromatography (RP LC) were used in the first and second dimensions, respectively. The peak compression efficiency of this interface was investigated by analysis of ten standards. Good peak shapes of the ten standards were observed when the dilution ratio was over five and the co-eluate plug volume was less than 10μL. The 2D LC system was further applied to analysis of a crude extract of Panax ginseng leaves. Seventeen major constituents in the extract were monitored, which could not be well separated by one-dimensional (1D) HILIC or RP LC method in a long separation gradient. The FSS interface successfully achieved the efficient combination of HILIC and RP LC, and the 17 constituents in ginseng extract got well separated under the optimized conditions. The FSS interface has shown great potential for 2D LC analysis of complex natural product samples.

  2. Breakdown of Fermi liquid behavior near the hot spots in a two-dimensional model: A two-loop renormalization group analysis

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Vanuildo S. de [Instituto de Física, Universidade Federal de Goiás, 74.001-970 Goiânia, GO (Brazil); Freire, Hermann, E-mail: hfreire@mit.edu [Instituto de Física, Universidade Federal de Goiás, 74.001-970 Goiânia, GO (Brazil); Department of Physics, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States)

    2013-10-21

    Motivated by a recent experimental observation of a nodal liquid on both single crystals and thin films of Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+} {sub δ} by Chatterjee et al. [Nature Phys. 6 (2010) 99], we perform a field-theoretical renormalization group (RG) analysis of a two-dimensional model such that only eight points located near the “hot spots” on the Fermi surface are retained, which are directly connected by spin density wave ordering wavevector. We derive RG equations up to two-loop order describing the flow of renormalized couplings, quasiparticle weight, several order-parameter response functions, and uniform spin and charge susceptibilities of the model. We find that while the order-parameter susceptibilities investigated here become non-divergent at two loops, the quasiparticle weight vanishes in the low-energy limit, indicating a breakdown of Fermi liquid behavior at this RG level. Moreover, both uniform spin and charge susceptibilities become suppressed in the scaling limit which indicate gap openings in both spin and charge excitation spectra of the model.

  3. Development and validation of high performance liquid chromatographic method for analysis of clozapine.

    Science.gov (United States)

    Kaur, Harpreet; Bassi, Pallavi; Monif, Tausif; Khuroo, Arshad; Kaur, Gurpreet

    2013-05-01

    In this study a rapid, simple and sensitive assay to quantify clozapine in human plasma by using reverse phase high performance liquid chromatographic method has been developed. Clozapine was extracted from human plasma using a mixture of chloroform: n-hexane 50:50 employing liquid-liquid extraction method. The calibration curve was found to be linear in the concentration range of 25-800 ng/ml. The inter day and intra day assay accuracy and precision fulfilled the criteria specified by USFDA, Guidance for industry: bioanalytical method validation. Clozapine was found to be stable in human plasma after 6 h incubation at room temperature, 50 days storage at -27°C and freeze thaw cycles, as well as after reconstitution with mobile phase after 24 h of storage in refrigerator. The validated method offers the advantage of using minimum injection volume (25μl) and plasma sample volume (300μl). The extraction method is simple and single step with no back extraction step, thus, making this method applicable to determination of pharmacokinetic profiles and parameters.

  4. High performance liquid chromatographic method fo pyrantel tartrate in swine feeds and supplements.

    Science.gov (United States)

    Goras, J T

    1981-11-01

    A new method for the determination of pyrantel tartrate in swine feed an supplements has been developed because the current official AOAC method is not applicable to feeds co-medicated with tylosin. The new method involves: (a) leaching of drug from feed with methanolic NaCl solution, (b) removal of interfering substances by ion pair liquid-liquid extraction and high performance liquid chromatography, and (c) quantitation of pyrantel tartrate by monitoring the ultraviolet absorption of the effluent stream at 313nm. The method of standard addition is used to compensate for the effect of the feed matrix on drug recovery. No interference is encountered from tylosin, carbadox, lincomycin, non-drug components of feeds and supplements, or potential degradation products of pyrantel tartrate, i.e., cis isomer of pyrantel tartrate and (E)-N-(3-methylaminopropyl)-2-thiopheneacrylamide. Results for the assay of 3 lots each of feeds and supplements containing 0.0106 and 0.106% pyrantel tartrate, respectively, were within +/-4% of label claim. Coefficients of variation ranged from 1.6 to 1.8% for feeds and from 1.9 to 3.9% for supplements.

  5. Determination of Harmine and Harmaline in Peganum harmala Seeds by High-Performance Liquid Chromatography

    Science.gov (United States)

    Monsef-Esfahani, Hamid Reza; Faramarzi, Mohammad Ali; Mortezaee, Venus; Amini, Mohsen; Rouini, Mohammad Reza

    A High-Performance Liquid Chromatography (HPLC) method was developed for determination of harmine, harmaline, harmol and harmalol in the extract of Peganum harmala seeds. The sample preparation was performed using liquid-liquid extraction. Chromatographic separation was achieved with a Tracer Excel 120 ODSA (150x4.6 mm) column, using a mixture of potassium phosphate buffer (10 mM, pH 7.0): acetonitrile (100:30; v/v) as mobile phase, in an isocratic mode at 1.5 mL min-1. UV detection (λ = 330 nm) was used. The calibration curves were linear (r2>0.998) in the concentration range of 0.5-20 μg mL-1 for all analytes. The lower limit of quantification for all analytes was 0.5 μg mL-1. The within and between day precisions in the measurement of QC samples at three tested concentrations were in the range of 0.6-10.2% for all analytes. The HPLC method is able to measure the harmala alkaloids in the plant extract. The method has suitable reproducibility, sensitivity and resolution for routine and accurate use with UV detection.

  6. Surveillance of the Army’s Propellant Stockpile: Analysis of Stabilizer Content by High Performance Liquid Chromatography

    Science.gov (United States)

    1990-10-01

    high performance liquid chromatography to monitor the level of stabilizer and its daughter products in propellant. Three of those methods are presented along with statistics and some comments about their

  7. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY OF COBALT(III) MIXED LIGAND COMPLEXES WITH ACETYLACETONATE AND OXINATE AND MONOMETHYLOXINATE IONS

    National Research Council Canada - National Science Library

    Kidani, Yoshinori; Naga, Shinobu; Koike, Hisashi

    1976-01-01

    In the presence of Co(III) mixed ligand complexes with acetylacetonate, and oxinate and monomethyloxinate ions, the authors attempted to employ high performance liquid chromatography, HPLC, for the separation and purification...

  8. Sensitive determination of 4-O-methylhonokiol in rabbit plasma by high performance liquid chromatography and application

    Institute of Scientific and Technical Information of China (English)

    Ming-Yue Li; Yu-Hai Tang; Xia Liu; Hai-Yan Lu; Xi-Yan Shi

    2011-01-01

    A novel high performance liquid chromatographic method was developed for the determination of 4-O- methylhonokiol in rabbit plasma and was applied to its pharmacokinetic investigation. Plasma samples were treated by one-fold volume of methanol and acetoni

  9. Extraction and determination of hormones in cosmetics by homogeneous ionic liquid microextraction high-performance liquid chromatography.

    Science.gov (United States)

    Kang, Mingqin; Sun, Shuo; Li, Na; Zhang, Daihui; Chen, Mingyan; Zhang, Hanqi

    2012-08-01

    The homogeneous ionic liquid microextraction was applied to the extraction of hormones from cosmetics and the hormones were determined by high-performance liquid chromatography. 1-Hexyl-3-methylimidazolium tetrafluoroborate was used as extraction solvent. Ammonium hexafluorophosphate as used as ion-pairing agent. Several experimental parameters, including the volume of 1-hexyl-3-methylimidazolium tetrafluoroborate, amount of ammonium hexafluorophosphate and sodium chloride, extraction and centrifuge time, and the pH value, were optimized. The limits of detection and quantification for the analytes ranged from 0.03 to 0.24 ng/mL and from 0.10 to 0.79 ng/mL, respectively. The precision for determining the hormones was lower than 5.2%. The proposed method was successfully developed for the determination of hormones in real cosmetic samples.

  10. Determination of Four Pesticides in Soil by Homogeneous Ionic Liquid-based Microextraction Coupled with High-performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    YAN Rui; SHAO Ming-yuan; LIANG Zhen-fen; ZHANG Han-qi; YU Ai-min

    2013-01-01

    Homogeneous ionic liquid microextraction was developed for the simultaneceus extraction of dimethomorph,mefenacet,isoprothiolane and oxadiazon from soil.1-Butyl-3-methylimidazolium tetrafluoroborate was used as extraction solvent,and ammonium hexafluorophosphate was used as ion-pairing agent.High-performance liquid chromatography(HPLC) was employed for separation and determination of the analytes.The calibration curves show good linear relationship(r>0.9988).The recoveries are between 74.2% and 97.9% with relative standard deviations(RSDs) lower than 5.97%.The present method is free of volatile organic solvents,and expenditures of sample,extraction time and solvent are lower,compared with ultrasonic and Soxhlet extraction.There was no obvious difference in the extraction recoveries of pesticides obtained by the three extraction methods.

  11. A two-dimensional liquid-filled ionization chamber array prototype for small-field verification: characterization and first clinical tests.

    Science.gov (United States)

    Brualla-González, Luis; Gómez, Faustino; Vicedo, Aurora; González-Castaño, Diego M; Gago-Arias, Araceli; Pazos, Antonio; Zapata, Martín; Roselló, Joan V; Pardo-Montero, Juan

    2012-08-21

    In this work we present the design, characterization and first clinical tests of an in-house developed two-dimensional liquid-filled ionization chamber prototype for the verification of small radiotherapy fields and treatments containing such small fields as in radiosurgery, which consists of 2 mm × 2 mm pixels arranged on a 16×8 rectangular grid. The ionization medium is isooctane. The characterization of the device included the study of depth, field-size and dose-rate dependences, which are sufficiently moderate for a good operation at therapy radiation levels. However, the detector presents an important anisotropic response, up to ≃ 12% for front versus near-lateral incidence, which can impact the verification of full treatments with different incidences. In such a case, an anisotropy correction factor can be applied. Output factors of small square fields measured with the device show a small systematic over-response, less than 1%, when compared to unshielded diode measurements. An IMRT radiosurgery treatment has been acquired with the liquid-filled ionization chamber device and compared with film dosimetry by using the gamma method, showing good agreement: over 99% passing rates for 1.2% and 1.2 mm for an incidence-per-incidence analysis; 100% passing rates for tolerances 1.8% and 1.8 mm when the whole treatment is analysed and the anisotropy correction factor is applied. The point dose verification for each incidence of the treatment performed with the liquid-filled ionization chamber agrees within 1% with a CC01 ionization chamber. This prototype has shown the utility of this kind of technology for the verification of small fields/treatments. Currently, a larger device covering a 5 cm × 5 cm area is under development.

  12. Determination of captopril by high-performance liquid chromatography with direct electrogenerated chemiluminescence

    Science.gov (United States)

    Sun, Yonghua; Zhang, Zhujun; Zhang, Xinfeng

    2013-03-01

    Captopril exhibit electrogenerated chemiluminescence (ECL) in NaNO3 solution when constant current is exerted. Based on this observation, a direct ECL method coupled with high-performance liquid chromatography (HPLC) separation is developed for determination of captopril in human serum. Factors affected the ECL emission are investigated. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of captopril in the range of 4.0 × 10-6-2.0 × 10-3 g mL-1 and the detection limit is 2 × 10-6 g mL-1 (S/N = 3). Compared with the common electrogenerated chemiluminescence experiments, the developed method need no any other fluorescence additives.

  13. Hydrocarbon group type determination in jet fuels by high performance liquid chromatography

    Science.gov (United States)

    Antoine, A. C.

    1977-01-01

    Results are given for the analysis of some jet and diesel fuel samples which were prepared from oil shale and coal syncrudes. Thirty-two samples of varying chemical composition and physical properties were obtained. Hydrocarbon types in these samples were determined by fluorescent indicator adsorption (FIA) analysis, and the results from three laboratories are presented and compared. Recently, rapid high performance liquid chromatography (HPLC) methods have been proposed for hydrocarbon group type analysis, with some suggestion for their use as a replacement of the FIA technique. Two of these methods were used to analyze some of the samples, and these results are also presented and compared. Two samples of petroleum-based Jet A fuel are similarly analyzed.

  14. Analysis of lipophilic pigments from a phototrophic microbial mat community by high performance liquid chromatography

    Science.gov (United States)

    Palmisano, A. C.; Cronin, S. E.; Des Marais, D. J.

    1988-01-01

    As assay for lipophilic pigments in phototrophic microbial mat communities using reverse phase-high performance liquid chromatography was developed which allows the separation of 15 carotenoids and chloropigments in a single 30 min program. Lipophilic pigments in a laminated mat from a commercial salina near Laguna Guerrero Negro, Baja California Sur, Mexico reflected their source organisms. Myxoxanthophyll, echinenone, canthaxanthin, and zeaxanthin were derived from cyanobacteria; chlorophyll c, and fucoxanthin from diatoms; chlorophyll a from cyanobacteria and diatoms; bacteriochlorophylls a and c, bacteriophaeophytin a, and gamma-carotene from Chloroflexus spp.; and beta-carotene from a variety of phototrophs. Sensitivity of detection was 0.6-6.1 ng for carotenoids and 1.7-12 ng for most chloropigments. This assay represents a significant improvement over previous analyses of lipophilic pigments in microbial mats and promises to have a wider application to other types of phototrophic communities.

  15. Simultaneous Determination of Five Components Including Acetaminophen by Reversed-phase High Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    ZHANG Li-qing; WU Xiao-hua; LU Ying; WANG Xia

    2004-01-01

    High performance liquid chromatography with a C18 reverse-phase column was used to separatethe five components in cough syrup, including acetaminophen, p-aminophenol, caffeine, chlorphenamine maleateand guaifenesin. The mobile phase consists of 15wi% acetonitrile, 0.004mol/L sodium heptyl sulfonate,0.03 mole/L potassium di- hydrogen phosphate and triethylamine ( volume ratio 13: 40: 44: 3), the pH of which isadjusted to 3.0 by phosphoric acid. The contents of the five components are analyzed on an ultraviolet spectropho-tometer at 254nm, with a flow rate of 0.4mL/min. The results show that the calibration curves are linear in acertain range. The average recovery of five components is between 96.31% and 102.3% .

  16. Determination of free urinary cortisol in cushing's syndrome using reversed-phase high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Eduardo Kinio Sugawara

    2010-01-01

    Full Text Available Determination of free urinary cortisol is a test of choice in the diagnosis of Cushing's syndrome. In this study, cortisol was quantified using reversed-phase high-performance liquid chromatography (RP-HPLC in urine samples previously extracted with ether and using triamcinolone acetonide as internal standard (IS. A BDS-Hypersil-C18® column, water-acetonitrile (72:28; v/v, with a flow rate of 1.0 mL/min and detection at 243 nm were used. This method showed to be both effective and efficient, with sensitivity and linearity ranging from 2.50 to 150 μg/L, and can be used in substitution to the radioimmunoassay technique within this concentration range.

  17. High performance liquid chromatography study of complex oxygenated alkane mixtures from organic aerosols

    Science.gov (United States)

    Kalafut-Pettibone, Alicia J.; Klems, Joseph P.; McGivern, W. Sean

    2013-05-01

    The composition of secondary organic aerosol particles is of primary importance both in identifying particle sources and in determining physical parameters, such as cloud condensation nucleus propensity. Further, measurements of composition are valuable in determining the chemistry of formation and aging. In this work, we describe the application of a recently-developed derivatization technique to a complex synthetic organic aerosol derived from the photolysis of 1-iodooctane. The technique utilizes high-performance liquid chromatography (HPLC) coupled to both ultravioletvisible (UV/VIS) spectroscopy and tandem mass spectrometry (MS-MS) to determine the overall distribution of hydroxyl (OH), non-acid carbonyl (C=O), and carboxylic acid (COOH) moieties as well as the specific identities of chromatographically separated products. This composition data will then be used to constrain models of the particle formation mechanisms.

  18. The search for more pH stable stationary phases for high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Collins, Carol H.; Silva, Cesar R.; Faria, Anizio M.; Collins, Kenneth E.; Jardim, Isabel Cristina S.F. [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Inst. de Quimica

    2009-07-01

    High performance liquid chromatographic (HPLC) separations are largely carried out using reversed phase conditions with stationary phases based on silica. A serious problem with these stationary phases is the tendency of silica to dissolve in high pH solutions often needed to separate basic compounds. The literature reports many different ways that have been tried to resolve this problem. This paper reports the results obtained in our laboratory with stationary phases prepared using silica supports having a layer of a metal oxide (zirconia or titania) attached on their surfaces, followed by immobilization of a polysiloxane or by organofunctionalization with a trimethoxyalkylsilane. Stability tests, also developed in our laboratory, indicate that the metal oxide layer increases the HPLC column lifetimes by making the stationary phase less susceptible to dissolution. (author)

  19. Analysis of carotenoid and porphyrin pigments of geochemical interest by high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Hajibrahim, S.K. (Univ. of Bristol, Eng.); Tibbetts, P.J.C.; Watts, C.D.; Maxwell, J.R.; Eglinton, G.; Colin, H.; Guiochon, G.

    1978-04-01

    High-performance liquid chromatography (HPLC) is shown to be a powerful tool in the analysis of carotenoid and porphyrin pigments. Columns packed with 5-..mu..m irregular silica gel particles by a high density and high constant pressure method allow efficient separation of mixtures of total nonsaponifiable carotenoids from recent sedimentary situations. Good reproducibility of retention times (within 2%) is achieved in the gradient elution mode. However, attention must be paid to reequilibration of the column after each injection by washing with the less polar solvent for a minimum of 15 min (for carotenoids) or of 30 min (for porphyrins). HPLC appears to be useful in ''fingerprinting'' petroporphyrin distributions in crude oil.

  20. Simultaneous determination of tricarboxylic acid cycle metabolites by high-performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Shurubor, Yevgeniya I; Cooper, Arthur J L; Isakova, Elena P; Deryabina, Yulia I; Beal, M Flint; Krasnikov, Boris F

    2016-06-15

    Here we describe a simple high-performance liquid chromatography (HPLC) procedure for the simultaneous detection and quantitation in standard solutions of 13 important metabolites of cellular energy metabolism, including 9 tricarboxylic acid (TCA) cycle components and 4 additional metabolites. The metabolites are detected by their absorbance at 210 nm. The procedure does not require prior derivatization, and an analysis can be carried out at ambient temperature within 15 min. The significance of the current work is that the current HPLC procedure should motivate the development of simplified TCA cycle enzyme assays, isotopomer analysis, and determination of selected TCA metabolite levels in plasma/tissues. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Development of N-ferrocenyl(benzoyl)amino-acid esters stationary phase for high performance liquid chromatography.

    Science.gov (United States)

    Zhou, Xiaohua; Li, Xiaole; Cao, Aijuan; Lijun, Qiao; Yu, Ajuan; Zhang, Shusheng; Wu, Yangjie

    2015-11-01

    A new stationary phase for high-performance liquid chromatography was prepared by covalently bonding N-ferrocenyl(benzoyl)amino-acid esters (L(1)) onto silica gel using 3-aminopropyltriethoxysilane as coupling reagent. The structure of new material was characterized by infrared spectroscopy, elemental analysis and thermogravimetric analysis. The chromatographic behavior of the phase was illustrated in reversed-phase (RP) and normal-phase (NP) modes using polycyclic aromatic hydrocarbons (PAHs), aromatics positional isomers, amines, 5-nitroimidazoles, organophosphorus pesticides and phenols as probes. Multiple mechanisms including hydrophobic, hydrogen bonding, π-π, dipole-dipole, charge-transfer and acid-base equilibrium interactions are involved. Thus, multi-interaction mechanisms and mixed-mode separation of the new phase can very likely guarantee its excellent chromatographic performance for the analysis of complex samples. The L(1) AminoSil column was successfully employed for the analysis of organophosphorus pesticides in vegetable.

  2. Quantitative determination of gibberellins by high performance liquid chromatography from various gibberellins producing Fusarium strains.

    Science.gov (United States)

    Bhalla, Kirti; Singh, Shashi Bala; Agarwal, Rashmi

    2010-08-01

    High performance liquid chromatographic (HPLC) method was developed for analysis of seven gibberellins, i.e., GA3, GA4, GA7, GA3 methyl ester, GA7 methyl ester 3,13 diacetate, GA7 methyl ester, and fusaric acid, using an isocratic system. Method was used for estimation of gibberellins from different Fusarium strains. Gibberellins were extracted from 28 strains of Fusarium, out of which six strains of Fusarium were isolated from soil of different parts of India and 22 strains were procured from the Indian Type Culture Collection, Indian Agricultural Research Institute, New Delhi. Extracts were analyzed for qualitative and quantitative estimation of gibberellins by thin layer chromatography and HPLC, respectively. On the basis of quantitative analysis of produced gibberellins by HPLC, they were categorized as low, moderate, and high gibberellin producing strain. For the first time, Fusarium solani was also reported as high GA3 producing strain.

  3. DETERMINATION OF PROTEINS FROM BUFFALO MILK USING HIGH PERFORMANCE LIQUID CROMATOGRAPHY RP-HPLC

    Directory of Open Access Journals (Sweden)

    AURELIA PECE

    2013-12-01

    Full Text Available In the hereby paper, we have undertaken a study on buffalo milk proteins, employing high performance liquid chromatography (HPLC. This RP-HPLC technique is commonly employed in the separation and assessment of caseins K, and in the fresh, as well as processed milk. These methods are also successfully applied in the authenticity and origin assessment of certain cheese products and the qualitative analysis of milk in bubalines, ovines, caprines and bovines (Ferreira si Cacote, 2003; Veloso si colab., 2002. In order to identify the main protein types, we found support in literature data (Miranda si colab., 2004, and thus achieved the chromatographic separation on whole milk, lactoserum and casein samples.

  4. Creation of reversed phase high-performance liquid chromatographic technique to assay platelet-activating factor

    Institute of Scientific and Technical Information of China (English)

    杨云梅; 曹红翠; 徐哲荣; 陈晓明

    2004-01-01

    Objective: To establish a new assay for platelet-activating factor (PAF), to compare it with bio-assay; and to discuss its significance in some elderly people diseases such as cerebral infarction and coronary heart disease. Methods: To measure PAF levels in 100 controls, 23 elderly patients with cerebral infarction and 65 cases with coronary heart disease by reversed phase high-performance liquid chromatographic technique (rHPLC). Results: rHPLC is more convenient, sensitive, specific, and less confusing, compared with bio-assay. The level of plasma PAF in patients with cerebral infarction was higher than that in the controls (P<0.01), and in patients with coronary heart disease. Conclusion: Detection of PAF with rHPLC is more reliable and more accurate. The new assay has important significance in PAF research.

  5. Creation of reversed phase high-performance liquid chromatographic technique to assay platelet-activating factor

    Institute of Scientific and Technical Information of China (English)

    杨云梅; 曹红翠; 徐哲荣; 陈晓明

    2004-01-01

    Objective: To establish a new assay for platelet-activating factor (PAF), to compare it with bio-assay; and to discuss its significance in some elderly people diseases such as cerebral infarction and coronary heart disease. Methods: To measure PAF levels in 100 controls, 23 elderly patients with cerebral infarction and 65 cases with coronary heart disease by reversed phase high-performance liquid chromatographic technique (rHPLC). Results:rHPLC is more convenient, sensitive,specific, and less confusing, compared with bio-assay. The level of plasma PAF in patients with cerebral infarction was higher than that in the controls (P<0.01), and in patients with coronary heart disease. Conclusion: Detection of PAF with rHPLC is more reliable and more accurate. The new assay has important significance in PAF research.

  6. [Detection of the preservative chlorphenesin in cosmetics by high-performance liquid chromatography].

    Science.gov (United States)

    Ikarashi, Yoshiaki; Miyazawa, Norimasa; Shimamura, Kimio; Sato, Nobuo; Yoshizawa, Ken-ichi; Hayashi, Masahito; Takano, Katsuhiro; Miyamoto, Michiko; Kojima, Takashi; Sakaguchi, Hiroshi; Fujiio, Makiko

    2009-01-01

    A simple determination method for preservative chlorphenesin in cosmetics was developed. Cosmetic samples were dissolved in methanol. The sample solution was analyzed by high-performance liquid chromatography (HPLC) with ODS column, using water-methanol (55:45) or water-acetonitrile (3:1) adjusted to pH 2.5 with phosphoric acid as the mobile phase. Chlorphenesin was detected with ultraviolet light detection at 280 nm. A linear relation was obtained between the peak areas and the concentrations of chlorphenesin in the range of 1-500 microg/ml. The determination limit of chlorphenesin was 1-2 microg/ml. Recoveries of chlorphenesin spiked in lotion and milky lotion at the levels of 0.03% and 0.3% were 98.8-100.0%. This method was applied for cosmetics including 0.03% and 0.3% of chlorphenesin and their content corresponded with the determined values.

  7. High-performance liquid chromatographic analysis of anthraquinone compounds in the Laurera benguelensis

    Science.gov (United States)

    Manojlović, N.; Marković, Z.; Gritsanapan, W.; Boonpragob, K.

    2009-09-01

    A high-performance liquid chromatographic (HPLC) method has been developed for the characterization of anthraquinone metabolites in extracts of the lichen Laurera benguelensis. With this method four anthraquinone derivatives 1,8-dihydroxy-3-methoxy-6-methylanthraquinone, 1,8-dihydroxy-3-formyl-6-methoxyanthraquinone, 1,8-dihydroxy-3-hydroxymethyl-6-methoxy-anthraquinone and 1,3,8-trihyroxy-6-methylanthraquinone can be analyzed. Components of lichen were detected by characteristic ultraviolet spectra and relative retention times. This is first report of phytochemical analysis of L. benguelensis. Importance of this research is in recognizing some new source (lichen and its extracts) as a natural emplacement of antioxidants because oxidation with free radicals or autooxidation is big problem for preservation of food products.

  8. Postcolumn photolysis of pesticides for fluorometric determination by high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Miles, C.J.; Moye, H.A.

    1988-02-01

    A high-performance liquid chromatography postcolumn reaction detector that employs UV photolysis with an optional reaction by using o-phthalaldehyde-2-mercaptoethanol (OPA-MERC) followed by fluorescence detection was found to be useful for several classes of pesticides. In the presence of the OPA-MERC reagent, most carbamates, carbamoyl oximes, carbamothioic acids, and substituted ureas gave a sensitive response while the response of dithiocarbamates, phenylamides, and phenylcarbamates varied. The response of most of the pesticides tested was significantly affected by the solvent used. Method detection limits for aldicarb sulfoxide, aldicarb, propoxur, thiram, and neburon in ground water were 2.5, 2.3, 3.3, 3.8, and 2.0 ..mu..g/L, respectively. In the absence of OPA-MERC reagent, several of the substituted aromatic compounds also gave strong fluorescence after photolysis. This detector is applicable to a broad range of nitrogenous pesticides.

  9. A high performance liquid chromatography method for determination of furfural in crude palm oil.

    Science.gov (United States)

    Loi, Chia Chun; Boo, Huey Chern; Mohammed, Abdulkarim Sabo; Ariffin, Abdul Azis

    2011-09-01

    A modified steam distillation method was developed to extract furfural from crude palm oil (CPO). The collected distillates were analysed using high performance liquid chromatography (HPLC) coupled with an ultraviolet diode detector at 284nm. The HPLC method allowed identification and quantification of furfural in CPO. The unique thermal extraction of CPO whereby the fresh fruit bunches (FFB) are first subjected to steam treatment, distinguishes itself from other solvent-extracted or cold-pressed vegetable oils. The presence of furfural was also determined in the fresh palm oil from FFB (without undergoing the normal extraction process), palm olein, palm stearin, olive oil, coconut oil, sunflower oil, soya oil and corn oil. The chromatograms of the extracts were compared to that of standard furfural. Furfural was only detected in CPO. The CPO consignments obtained from four mills were shown to contain 7.54 to 20.60mg/kg furfural.

  10. Determination of 15 isoflavone isomers in soy foods and supplements by high-performance liquid chromatography.

    Science.gov (United States)

    Yanaka, Kaoru; Takebayashi, Jun; Matsumoto, Teruki; Ishimi, Yoshiko

    2012-04-25

    Soy isoflavone is the generic name for the isoflavones found in soy. We determined the concentrations of 15 soy isoflavone species, including 3 succinyl glucosides, in 22 soy foods and isoflavone supplements by high-performance liquid chromatography (HPLC). The total isoflavone contents in 14 soy foods and 8 supplements ranged from 45 to 735 μg/g and from 1,304 to 90,224 μg/g, respectively. Higher amounts of succinyl glucosides were detected in natto, a typical fermented soy product in Japan; these ranged from 30 to 80 μg/g and comprised 4.1-10.9% of the total isoflavone content. In soy powder, 59 μg/g of succinyl glucosides were detected, equivalent to 4.6% of the total isoflavone content. These data suggest that the total isoflavone contents may be underestimated in the previous studies that have not included succinyl glucosides, especially for Bacillus subtilis -fermented soy food products.

  11. A simple high performance liquid chromatography method for determination of rebamipide in rat urine.

    Science.gov (United States)

    Cooper, Dustin L; Harirforoosh, Sam

    2014-01-01

    Rebamipide is a mucoprotective agent commonly used to prevent nonsteriodal anti-inflammatory drug-induced gastrointenstinal side effects [1]. Human plasma and urine analysis of rebamipide utilizing high performance liquid chromatography (HPLC) have been reported [2]. Recently, we reported on the plasma levels of rebamipide in presense or absence of celecoxib or diclofenac in rats [3] using a modified HPLC method of detection developed by Jeoung et al. [4]. To tailor the method towards use in urinary rebamipide extraction and analysis, the following modifications were made:•To compensate for high concentrations of rebamipide found in urine, a new rebamipide stock solution was prepared with a final concentration of 50,000 ng/mL.•Rat urine calibration standards were obtained within the range of 50-1000 ng/mL and 1000-50,000 ng/mL.•Plasma samples were replaced with urine samples.

  12. A validated new method for nevirapine quantitation in human plasma via high-performance liquid chromatography.

    Science.gov (United States)

    Silverthorn, Courtney F; Parsons, Teresa L

    2006-01-01

    A fully validated and clinically relevant assay was developed for the assessment of nevirapine concentrations in neonate blood plasma samples. Solid-phase extraction with an acid-base wash series was used to prepare subject samples for analysis. Samples were separated by high performance liquid chromatography and detected at 280 nm on a C8 reverse-phase column in an isocratic mobile phase. The retention times of nevirapine and its internal standard were 5.0 and 6.9 min, respectively. The method was validated by assessment of accuracy and precision (statistical values 0.996) and the average recovery was 93% (n = 18). The lower limit of quantification (relative standard deviation <20%) was determined to be 25 ng/mL for 50 microL of plasma, allowing detection of as little as 1.25 ng of nevirapine in a sample. This value represents an increase in sensitivity of up to 30-fold over previously published methods.

  13. Determination of Sex Hormones in Antler Velvet by High Performance Liquid Chromatography Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    LU Chun-mei; WANG Ming-tai; MU Jun; BAI Yu-ping; DU Jian-shi; ZHANG Han-qi; WANG Jian-wei

    2012-01-01

    Eighteen sex hormones in antler velvet were determined by high performance liquid chromatography tandem mass spectrometry.The solid phase extraction was applied to eliminating the matrix effect.The experimental conditions were examined and optimized.Under the optimal conditions,the proposed method provides the good linearities and determination limits(0.2-1.0 μg/kg)of the analytes investigated.The recoveries ranging from 72.3% to 149.5% were obtained for the target analytes at two concentration levels.This method was applied to the determination of eighteen sex hormones in different kinds of antler velvet samples and the obtained results are satisfactory.The results indicate that the proposed method is suitable for the determination of sex hormones in antler velvet samples.

  14. Improved high-performance liquid chromatographic analysis of terazosin in human plasma.

    Science.gov (United States)

    Cheah, P Y; Yuen, K H; Liong, M L

    2000-08-18

    A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method was developed for the determination of terazosin in human plasma. The method involves a one-step single solvent extraction procedure using dichloromethane with a 0.25 ml plasma sample. Recovery values were all greater than 90% over the concentration range 0.25-100 ng/ml. Terazosin was found to adsorb to glass or plastic tubes, but this could be circumvented by using disposable plastic tubes. Also, rinsing the injector port with methanol after each injection helped to prevent any carry-over effect. The internal standard, prazosin, did not exhibit this problem. The method has a quantification limit of 0.25 ng/ml. The within- and between-day coefficient of variation and accuracy values were all less than 7% over the concentration range 0.25-100 ng/ml and hence the method is suitable for use in pharmacokinetic studies of terazosin.

  15. Measurement of serum pralidoxime methylsulfate (Contrathion) by high-performance liquid chromatography with electrochemical detection.

    Science.gov (United States)

    Houzé, Pascal; Borron, Stephen W; Scherninski, François; Bousquet, Bernard; Gourmel, Bernard; Baud, Frédéric

    2005-01-05

    Pralidoxime methylsulfate (Contrathion) is widely used to treat organophosphate poisoning. Despite animal and human studies, the usefulness of Contrathion therapy remains a matter of debate. Therapeutic dosage regimens need to be clarified and availability of a reliable method for plasma pralidoxime quantification would be helpful in this process. We here describe a high-performance liquid chromatography technique with electrochemical detection to measure pralidoxime concentrations in human serum using guanosine as an internal standard. The assay was linear between 0.25 and 50 microg mL(-1) with a quantification limit of 0.2 microg mL(-1). The analytical precision was satisfactory, with variation coefficients lower 10%. This assay was applied to the analysis of a serum from an organophosphorate poisoned patient and treated by Contrathion infusions (100 and 200 mg h(-1)) after a loading dose (400 mg).

  16. Determination of triazine herbicides in milk by cloud point extraction and high-performance liquid chromatography.

    Science.gov (United States)

    Liu, Tiantian; Cao, Peng; Geng, Jinpei; Li, Jinqiang; Wang, Mingzhen; Wang, Minglin; Li, Xiaoyu; Yin, Dalu

    2014-01-01

    High-performance liquid chromatography with UV detection was used to detect four triazines in milk. An efficient pretreatment method known as cloud point extraction (CPE) was proposed for extracting and preconcentrating analytes. The parameters of CPE including surfactant type and concentration, electrolyte, sample pH, incubation temperature and duration were investigated. Under optimal conditions, satisfying recoveries in the range of 70.5-96.9% were achieved for four triazines. The limits of detection ranged from 6.79 to 11.19μg L(-1). The linear range of quantitation for the four triazines was 50-2000μg L(-1), and the correlation coefficients of the calibration curves were all 0.9999. The results demonstrated that the proposed method was efficient and reliable for the determination of triazine herbicides in milk samples.

  17. Development of High Performance Liquid Chromatography and Mass Spectrometry:a Key Engine of TCM Modernization

    Institute of Scientific and Technical Information of China (English)

    Zheng-Xiang Zhang; Xue Qiao; Min Ye; Man-Yu Zhang; Yue Song; Tao Bo

    2015-01-01

    Traditional Chinese Medicine (TCM) has been popular for thousand years in prevention and treatment of chronic diseases synergistically with Western medicine while producing mild healing effects and lower side effects. Although many TCMs have been proven effective by modern pharmacological studies and clinical trials, their bioactive constituents and the remedial mechanisms are still not well understood. Researchers have made great efforts to explore the real theory of TCM for many years with different strategies. Development of high performance liquid chromatography (HPLC) and mass spectrometry within recent decade can provide scientists with robust technologies for disclosing the mysterious mask of TCM. In this paper, important innovations of HPLC and mass spectrometry are reviewed in the application of TCM analysis from single compound identification to metabolomic strategy.

  18. High-performance liquid chromatographic determination of alpha-tocopherol in macroalgae.

    Science.gov (United States)

    Sánchez-Machado, D I; López-Hernández, J; Paseiro-Losada, P

    2002-11-08

    A high-performance liquid chromatographic (HPLC) method for the microscale determination of alpha-tocopherol in macroalgae is reported. The method includes microscale saponification and extraction with n-hexane. The presence of alpha-tocopherol in macroalgae samples was confirmed by HPLC-MS. Alpha-tocopherol levels as determined in samples by HPLC with UV and fluorescence detection did not differ significantly; however, fluorescence detection has a higher sensitivity (detection limit 10.4 ng/ml, vs. 104 ng/ml with UV detection), as well as good precision (relative standard deviation 1.81%) and recovery (94.3%). Fluorescence detection is also faster. We used this method to determine the alpha-tocopherol contents of four commercial macroalgae products from northwest Spain as part of nutritional studies in dehydrated Himanthalia elongata and Laminaria ochroleuca, and also in canned Himanthalia elongata and Saccorhiza polychides.

  19. High-Performance Liquid Chromatographic Method for Determination of Germacrone in Rat Plasma

    Institute of Scientific and Technical Information of China (English)

    HEHai-bing; TANGXing; CUIFu-de

    2004-01-01

    Aim A reliable high-performance liquid chromatographic (HPLC) method was developed for determination of gennacrone in rat. plasma. Methods The plasma samples were treated with acetonitrile and analyzed by HPLC with UV detection at 244 nm. Results The limit of detection was 100 ng·mL-1 for germacrone in plasma and the linear range was0.1004-15.06μg· mL-1 in plasma. The RSD of intra-day and inter-day assay was 1.87%-4.29% and 1.29%-5.15%, respectively. The recoveries of germacrone were over 95%. The endogenous substances in plasma did not show any interference in the analysis. Conclusion The method is accurate and convenient, and suitable for pharmacokinetic studies of gennacrone in rats.

  20. Detection of cheese whey and caseinomacropeptide in fermented milk beverages using high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    E.H.P. Andrade

    2014-06-01

    Full Text Available Cheese whey level and caseinomacropeptide (CMP index of fermented milk beverages added with four levels of cheese whey (0, 10, 20, and 40% and stored at 8-10oC for 0, 7, 14 and 21 days were determined by high performance liquid chromatography-gel filtration (HPLC-GF. Additionally, the interference of the starter culture and the storage time on the detection of cheese whey and CMP were investigated. Refrigerated storage up to 21 days did not affect (P>0.05 cheese whey and CMP amounts in milk (0% of cheese whey and in fermented milk beverages added with 10 and 20% of cheese whey (P>0.05. However, cheese whey and CMP amounts were higher than expected (P<0.05 in fermented milk beverages added with 40% of cheese whey and stored for 21 days.

  1. Tritium isotope effect in high-performance liquid chromatography of eicosanoids

    Energy Technology Data Exchange (ETDEWEB)

    Do, U.H.; Lo, S.-L.; Iles, J.; Rosenberger, T.; Tam, P.; Hong, Y.; Ahern, D. [DuPont, NEN Products, Boston (United States). Lipids Group

    1994-07-01

    A significant difference in retention time between unlabeled and the corresponding multi-tritium-labeled eicosanoid has been observed in the high performance liquid chromatography (HPLC) analysis of 11 eicosanoids. Variations in retention time range from 3-7%, depending on the separation conditions as well as the number and position of the tritium substitution. Multi-tritium-labeled eicosanoids were eluted earlier than the corresponding unlabeled eicosanoid in reversed phase HPLC, whereas no isotope effect was seen with {sup 14}C- and {sup 3}H{sub 2}-eicosanoids. Considerations must be given to this tritium isotope effect whenever both multi-tritium-labeled and unlabeled eicosanoids are used for HPLC cochromatography or recovery studies. (author).

  2. High-performance liquid chromatography determination of dapsone, monoacetyldapsone, and pyrimethamine in filter paper blood spots

    DEFF Research Database (Denmark)

    Rønn, A M; Lemnge, M M; Angelo, H R

    1995-01-01

    A high-performance liquid chromatography method for the simultaneous analysis of dapsone (DDS), the major metabolite of DDS, monoacetyldapsone (MADDS), and pyrimethamine (PYR) was modified for capillary blood samples obtained by finger prick and dried on filter paper. Limit of quantitation using...... 150 microliters whole blood dried on filter paper was found to be 20 ng/ml for DDS and PYR and 15 ng/ml for MADDS (precision ... paper method and the original whole-blood method was almost comparable. Standardization could therefore be obtained by the more simple whole-blood method. Dried filter paper samples stored at 19-22 degrees C were stable for months and for 2 weeks stored at 35 degrees C. The concentrations...

  3. Determination of primary amino acids in wines by high performance liquid magneto-chromatography.

    Science.gov (United States)

    Barrado, E; Rodriguez, J A; Castrillejo, Y

    2009-05-15

    Eight amino acids (ethanolamine, glycine, alanine, beta-aminobutyric acid, leucine, methionine, histidine and asparagine) were identified and quantified in Spanish wines by high performance liquid magneto-chromatography (HPLMC) with UV-V spectrophotometry. For this method, the amino acids are first complexed with mono(1,10-phenanthroline)-Cu(II) to confer them paramagnetic properties, and then separated by application of a low magnetic field intensity (5.5 mT) to the stationary phase contained in the chromatographic column. Principal components analysis of the results obtained grouped together the wine samples according to their denomination of origin: "Ribera del Duero", "Rueda" or "Rioja" (Spain). Through cluster analysis, a series of correlations was also observed among certain amino acids, and between these groupings and the type of wine. These clusters were found to reflect the role played by the amino acids as primary or secondary nutrients for the bacteria involved in alcoholic and malolactic fermentation.

  4. Rocket-powered high-performance liquid chromatographic analysis of plant ascorbate and glutathione.

    Science.gov (United States)

    Davey, M W; Dekempeneer, E; Keulemans, J

    2003-05-01

    We describe a robust procedure for the extraction and high-performance liquid chromatographic analysis of L-ascorbate (vitamin C), glutathione (gamma-glutamyl cysteinylglycine), and their respective oxidized forms from various plant tissues. Parameters such as the choice of extraction buffer, tissue disruption technique, sample stability, and separation conditions have all been optimized. In particular we found that the inclusion of the reducing agent dithiothreitol as a "stabilizer" in extracts with high phenolic content actually promoted oxidation of these antioxidants. Further, by using commercially available short "Rocket" HPLC columns in combination with high mobile-phase flow rates, analysis times were reduced to only 6min, making the method suitable for the high-resolution screening of large numbers of samples.

  5. Development of high performance liquid chromatography method for miconazole analysis in powder sample

    Science.gov (United States)

    Hermawan, D.; Suwandri; Sulaeman, U.; Istiqomah, A.; Aboul-Enein, H. Y.

    2017-02-01

    A simple high performance liquid chromatography (HPLC) method has been developed in this study for the analysis of miconazole, an antifungal drug, in powder sample. The optimized HPLC system using C8 column was achieved using mobile phase composition containing methanol:water (85:15, v/v), a flow rate of 0.8 mL/min, and UV detection at 220 nm. The calibration graph was linear in the range from 10 to 50 mg/L with r 2 of 0.9983. The limit of detection (LOD) and limit of quantitation (LOQ) obtained were 2.24 mg/L and 7.47 mg/L, respectively. The present HPLC method is applicable for the determination of miconazole in the powder sample with a recovery of 101.28 % (RSD = 0.96%, n = 3). The developed HPLC method provides short analysis time, high reproducibility and high sensitivity.

  6. High-performance liquid chromatography for determination of α-tocopherol in vegetables

    Directory of Open Access Journals (Sweden)

    Marcin Horbowicz

    2013-12-01

    Full Text Available A simple method for the determination of α-tocopherol in vegetables is described. The procedure consists of the following steps: saponification, extraction, silica-column clean-up, and high-performance liquid chromatography. Elution time for D, L-α-tocopherol was 9.0 min using a Zorbax Sil (250 x 4.6 mm column and an isocratic mobile phase of hexane-methanol (99.3 + 0.7, with a flow rate of 1 ml/min, and detection at 292 nm using a variable UV detector. The average recovery of α-tocopherol was 91.2%, and the minimum detectable amount was 0.1 mg/100 g of fresh vegetable tissue. This method is comparable to gas-chromatographic determination of α-tocopherol, but has fewer analytical steps and gives more reproducible results.

  7. High-performance liquid chromatographic determination of vertilmicin in rat plasma using sensitive fluorometric derivatization.

    Science.gov (United States)

    Liu, Zhen; Sha, Yunfei; Huang, Taomin; Yang, Bei; Duan, Geng-Li

    2005-12-15

    A sensitive and reliable high-performance liquid chromatographic method was developed for the determination of vertilmicin in rat plasma. Derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) followed by C(18) reversed-phase chromatography allowed the fluorimetric detection of vertilmicin. Optimal conditions for the derivatization of vertilmicin are described. The limit of quantification was 0.02 mg/L. The pharmacokinetics of vertilmicin was studied in 24 rats following intramuscular injection (i.m.) of different doses (4, 8, 16, 32 mg/kg of body weight). The pharmacokinetic parameter values were estimated by use of 3P97 program. In this study, we assessed the dose proportionality of vertilmicin after single intramuscular injection doses and obtained new information on the pharmacokinetics of the compound.

  8. Determination of artificial sweeteners in beverages and special nutritional products using high performance liquid chromatography.

    Science.gov (United States)

    Serdar, Maja; Knežević, Zorka

    2011-06-01

    This paper presents two high performance liquid chromatographic (HPLC) methods used for the separation and determination of artificial sweeteners aspartame, acesulphame K, sodium saccharin, and sodium cyclamate in beverages and special nutritional products (special food intended for specific population groups). All four compounds are soluble in aqueous solutions and can easily be separated and determined by HPLC with a diode array detector (DAD). The first method involved separation of aspartame, acesulphame K, and sodium saccharin on a C18 column with an isocratic elution of phosphate buffer and acetonitrile as mobile phase. The second method was used to separate sodium cyclamate on a C18 column with methanol and water as mobile phase. Under optimum conditions, both methods showed good analytical performance, such as linearity, precision, and recovery. The methods were successfully applied for the analysis of real samples of soft drinks and special nutritional products.

  9. Quantitative determination of acetaminophen, phenylephrine and carbinoxamine in tablets by high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Carina de A. Bastos

    2009-01-01

    Full Text Available An alternative methodology for analysis of acetaminophen (Ace, phenylephrine (Phe and carbinoxamine (Car in tablets by ion-pair reversed phase high performance liquid chromatography was validated. The pharmaceutical preparations were analyzed by using a C18 column (5 μm, 300 mm, 3.9 mm and mobile phase consisting of 60% methanol and 40% potassium monobasic phosphate aqueous solution (62.46 mmol L-1 added with 1 mL phosphoric acid, 0.50 mL triethylamine and 0.25 g sodium lauryl sulfate. Isocratic analysis was performed under direct UV detection at 220 nm for Phe and Car and at 300 nm for Ace within 5 min.

  10. High Performance Liquid Chromatography of the Dansyl Derivatives of Putrescine, Spermidine, and Spermine 1

    Science.gov (United States)

    Escribano, M. Isabel; Legaz, M. Estrella

    1988-01-01

    A high performance liquid chromatographic (HPLC) method, based on dansylation and fluorescence detection, is described for the estimation of putrescine, spermidine, and spermine in lichen (Evernia prunastri [L.]) samples. Because of the high concentrations of phenols and salts, dansylation was followed by a pre-HPLC purification step. Both flow rate and mobile phase (methanol:water) followed a gradient for optimum resolution on a reverse-phase column. Amounts as small as 0.3 picomole of standard polyamines could be detected. In applying the method to lichens, it was found that 5.45% (w/w) of the exogenous putrescine taken up by the thallus was unbound in the algal partner and that 60% (w/w) was conjugated in the thallus, perhaps to lichen phenolics. PMID:16666175

  11. High performance liquid chromatography of the dansyl derivatives of putrescine, spermidine, and spermine.

    Science.gov (United States)

    Escribano, M I; Legaz, M E

    1988-06-01

    A high performance liquid chromatographic (HPLC) method, based on dansylation and fluorescence detection, is described for the estimation of putrescine, spermidine, and spermine in lichen (Evernia prunastri [L.]) samples. Because of the high concentrations of phenols and salts, dansylation was followed by a pre-HPLC purification step. Both flow rate and mobile phase (methanol:water) followed a gradient for optimum resolution on a reverse-phase column. Amounts as small as 0.3 picomole of standard polyamines could be detected. In applying the method to lichens, it was found that 5.45% (w/w) of the exogenous putrescine taken up by the thallus was unbound in the algal partner and that 60% (w/w) was conjugated in the thallus, perhaps to lichen phenolics.

  12. High-performance liquid chromatographic assay detects pentamidine metabolism by Fisher rat liver microsomes.

    Science.gov (United States)

    Tuttle, R H; Hall, J E; Tidwell, R R

    1997-01-24

    Fisher rat liver microsomes metabolized the antimicrobial drug pentamidine to four new compounds detected by gradient elution reversed-phase high-performance liquid chromatography with variable wavelength detection. Coelution experiments with pentamidine metabolite standards determined the new peaks to be previously identified hydroxylated metabolites of pentamidine, with 1,5-bis(4'-amidinophenoxy)-3-pentanol and 1,5-di-(4'-amidinophenoxy)-2-pentanol formed in the greatest amount. The data contradict a previous report that Fisher rat liver homogenates do not metabolize pentamidine. Pentamidine and its known primary metabolites have almost identical absorption spectra; thus, pentamidine metabolism must be evaluated using gradient elution HPLC to resolve pentamidine from its metabolites. The current assay has now been used to demonstrate that Fisher and Sprague-Dawley rat, mouse, rabbit and human liver microsomes all metabolize pentamidine in vitro.

  13. DETERMINATION OF FLUCONAZOLE IN HUMAN PLASMA BY REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY.

    Science.gov (United States)

    Safaei, Zahra; Alipour, Eskandar; Shafaati, Alireza; Zarghp, Afshin

    2015-01-01

    A rapid, simple and reproducible high performance liquid chromatographic method was developed and validated for determination of fluconazole in human plasma. The separation was performed on MZ C8 column (125 x 4 mm, 5 µm) using acetonitrile - potassium dihydrogen phosphate buffer (15 : 85, v/v), pH 3.0, as the mobile phase at a flow rate of 1.5 mL/min. The wavelength was set at 261 nm. The assay enables the measurement of fluconazole for therapeutic drug monitoring with a minimum quantification limit of 20 ng/mL. The method involves simple, protein precipitation procedure and analytical recovery was complete. The calibration curve was linear over the concentration range 0.1-4 µg/mL. The coefficients of variation for inter-day and intra-day assay were found to be less than 10%.

  14. Microwave-assisted ionic liquid homogeneous liquid-liquid microextraction coupled with high performance liquid chromatography for the determination of anthraquinones in Rheum palmatum L.

    Science.gov (United States)

    Wang, Zhibing; Hu, Jianxue; Du, Hongxia; He, Shuang; Li, Qing; Zhang, Hanqi

    2016-06-01

    The microwave-assisted ionic liquid homogeneous liquid-liquid microextraction (MA-IL-HLLME) coupled with high performance liquid chromatography with diode array detection (HPLC-DAD) was developed for the determination of anthraquinones, including aloe-emodin, emodin, chrysophanol and physcion in root of Rheum palmatum L. Several experimental parameters influencing the extraction efficiency, including amount of sample, type and volume of ionic liquid, volume and pH value of extraction medium, microwave power and extraction time, concentration of NH4PF6 as well as centrifugal condition were optimized. When 140μL of ionic liquid ([C8MIM][BF4]) was used as an extraction solvent, target analytes can be extracted from sample matrix in one minute with the help of microwave irradiation. The MA-IL-HLLME is simple and quick. The calibration curves exhibited good linear relationship (r>0.9984). The limits of detection and quantification were in the range of 0.015-0.026 and 0.051-0.088μgmL(-1), respectively. The spiked recovery for each analyte was in the range of 81.13-93.07% with relative standard deviations lower than 6.89%. The present method is free of volatile organic solvents, and represents lower expenditures of sample, extraction time and solvent, compared with ultrasonic and heat reflux extraction. The results indicated that the present method can be successfully applied to the determination of anthraquinones in medicinal plant.

  15. [Determination of five triazine herbicides in infant milk powder by high performance liquid chromatography coupled with ionic liquid-based homogeneous liquid-liquid microextraction].

    Science.gov (United States)

    Zhang, Liyuan; Yao, Di; Li, Na; Zhang, Hanqi; Yu, Aimin

    2015-07-01

    A high performance liquid chromatography coupled with homogeneous liquid-liquid microextraction was developed for the determination of five triazine herbicides in infant milk powders. The ionic liquid was used as microextraction solvent. The separation of the herbicides was performed on an Eclipse XDB-C18 column using acetonitrile and water as mobile phases in gradient mode. The effects of homogeneous liquid-liquid extraction conditions on the experimental results were investigated in detail. Under the optimized experimental conditions, the calibration curves for determining the analytes were linear and the correlation coefficients were ≥ 0.9992. The limits of detection for cyanazine, desmetryn, terbumeton, terbuthylazine and dimethametryn were 12.1, 13.8, 11.8, 14.6 and 13.7 μg/kg, respectively. The recoveries of the analytes spiked in four infant milk powders ranged from 92.2% to 103.2% and the relative standard deviations were lower than 6%. This method is sensitive, simple, and suitable for the determination of triazine herbicides in milk powder samples.

  16. Online polar two phase countercurrent chromatography×high performance liquid chromatography for preparative isolation of polar polyphenols from tea extract in a single step.

    Science.gov (United States)

    Chen, Wei-Bin; Li, Shu-Qi; Chen, Long-Jiang; Fang, Mei-Juan; Chen, Quan-Cheng; Wu, Zhen; Wu, Yun-Long; Qiu, Ying-Kun

    2015-08-01

    Herein, we report an on-line two-dimensional system constructed by counter-current chromatography (CCC) coupling with preparative high-performance liquid chromatography (prep-HPLC) for the separation and purification of polar natural products. The CCC was used as the first dimensional isolation column, where an environmental friendly polar two-phase solvent system of isopropanol and 16% sodium chloride aqueous solution (1:1.2, v/v) was introduced for low toxicity and favorable resolution. In addition, by applying the stop-and-go flow technique, effluents pre-fractionated by CCC was further purified by a preparative column packed with octadecyl silane (ODS) as the second dimension. The interface between the two dimensions was comprised of a 6-port switching valve and an electronically controlled 2-position 10-port switching valve connected with two equivalent holding columns. To be highlighted here, this rationally designed interface for the purpose of smooth desalination, absorption and desorption, successfully solved the solvent compatibility problem between the two dimensional separation systems. The present integrated system was successfully applied in a one-step preparative separation and identification of 10 pure compounds from the water extracts of Tieguanyin tea (Chinese oolong tea). In short, all the results demonstrated that the on-line 2D CCC×LC method is an efficient and green approach for harvesting polar targets in a single step, which showed great promise in drug discovery. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Towards early detection of the hydrolytic degradation of poly(bisphenol A)carbonate by hyphenated liquid chromatography and comprehensive two-dimensional liquid chromatography

    NARCIS (Netherlands)

    Coulier, L.; Kaal, E.R.; Hankemeier, Th.

    2006-01-01

    The hydrolytic degradation of poly(bisphenol A)carbonate (PC) has been characterized by various liquid chromatography techniques. Size exclusion chromatography (SEC) showed a significant decrease in molecular mass as a result of hydrolytic degradation, while 'liquid chromatography at critical

  18. Towards early detection of the hydrolytic degradation of poly(bisphenol A)carbonate by hyphenated liquid chromatography and comprehensive two-dimensional liquid chromatography

    NARCIS (Netherlands)

    Coulier, L.; Kaal, E.R.; Hankemeier, Th.

    2006-01-01

    The hydrolytic degradation of poly(bisphenol A)carbonate (PC) has been characterized by various liquid chromatography techniques. Size exclusion chromatography (SEC) showed a significant decrease in molecular mass as a result of hydrolytic degradation, while 'liquid chromatography at critical condit

  19. Flavonoid profiling of a traditional Chinese medicine formula of Huangqin Tang using high performance liquid chromatography

    Science.gov (United States)

    Li, Tao; Zhuang, Shuaixing; Wang, Yiwei; Wang, Yanli; Wang, Weihao; Zhang, Huihui; Chen, Li; Wang, Dunfang; Zhou, Zhongming; Yang, Weipeng

    2016-01-01

    The quality control processes for herbal medicines have been problematic. Flavonoids are the major active components of Huangqin Tang (HQT, a traditional Chinese medicine formula). In this study, we used a combinative method approach consisting of chromatographic fingerprinting (high performance liquid chromatography; HPLC), quantitative methods and a pharmacodynamic evaluation model to analyze the flavonoids of HQT obtained from different sources. Ten batches of HQT were analyzed by the HPLC fingerprinting method and 26 common peaks were detected, of which 23 peaks corresponded with the chemical profile of HQT. In addition, 11 major compounds were identified by LC–MS analysis (liquid chromatography–tandem mass spectrometer; LC–MSn) and quantified by the HPLC quantitative method approach. The studied 10 batches of HQT were found to be homogeneous in their composition with a similarity between 0.990 and 1.000. The distribution of the 11 identified compounds was found to be very similar among the batches. Only slight pharmacodynamic differences were detected between the different batches, confirming the homogeneity of HQT. The results of this study prove that the combination of chromatographic fingerprinting and quantitative analysis can be readily used for comprehensive quality control of herbal medicines. PMID:27006899

  20. Fully automated high-performance liquid chromatographic assay for the analysis of free catecholamines in urine.

    Science.gov (United States)

    Said, R; Robinet, D; Barbier, C; Sartre, J; Huguet, C

    1990-08-24

    A totally automated and reliable high-performance liquid chromatographic method is described for the routine determination of free catecholamines (norepinephrine, epinephrine and dopamine) in urine. The catecholamines were isolated from urine samples using small alumina columns. A standard automated method for pH adjustment of urine before the extraction step has been developed. The extraction was performed on an ASPEC (Automatic Sample Preparation with Extraction Columns, Gilson). The eluate was collected in a separate tube and then automatically injected into the chromatographic column. The catecholamines were separated by reversed-phase ion-pair liquid chromatography and quantified by fluorescence detection. No manual intervention was required during the extraction and separation procedure. One sample may be run every 15 min, ca. 96 samples in 24 h. Analytical recoveries for all three catecholamines are 63-87%, and the detection limits are 0.01, 0.01, and 0.03 microM for norepinephrine, epinephrine and dopamine, respectively, which is highly satisfactory for urine. Day-to-day coefficients of variation were less than 10%.

  1. Peak purity assessment in a triple-active fixed-dose combination drug product related substances method using a commercial two-dimensional liquid chromatography system.

    Science.gov (United States)

    Shackman, Jonathan G; Kleintop, Brent L

    2014-10-01

    Pharmaceutical formulations containing multiple active components challenge the development of analytical methods, especially as the individual active ingredients diverge in their physicochemical properties. Establishing specificity, especially peak purity, is one of the major evaluation criteria when developing a related substances method for drug substances or products. Fixed-dose combination products may not be amenable to common strategies for assessing peak purity, such as performing orthogonal separations, due to the complexity of the separation and/or diversity of the active ingredients. An alternate approach to evaluating peak purity is demonstrated for a triple-active component fixed-dose combination product under development. A commercially available automated two-dimensional liquid chromatography system was used to perform a selective comprehensive multidimensional separation of an active ingredient peak. The first dimension performed the drug product impurity/degradant profiling method; the second dimension assayed these fractions using the drug substance profiling method, which was pseudo-orthogonal to the first dimension. A total of 14 targeted fractions were sampled across the first dimension main peak, with 11 containing detectable analytes and the remaining fractions bracketing the main peak. This degree of sampling allowed profiling of a coeluting degradant present at a 0.2% w/w level throughout the main peak.

  2. Metabolite profiling of licorice (Glycyrrhiza glabra) from different locations using comprehensive two-dimensional liquid chromatography coupled to diode array and tandem mass spectrometry detection.

    Science.gov (United States)

    Montero, Lidia; Ibáñez, Elena; Russo, Mariateresa; di Sanzo, Rosa; Rastrelli, Luca; Piccinelli, Anna Lisa; Celano, Rita; Cifuentes, Alejandro; Herrero, Miguel

    2016-03-24

    Profiling of the main metabolites from several licorice (Glycyrrhiza glabra) samples collected at different locations is carried out in this work by using comprehensive two-dimensional liquid chromatography (LC × LC) coupled to diode array (DAD) and mass spectrometry (MS) detectors. The optimized method was based on the application of a HILIC-based separation in the first dimension combined with fast RP-based second dimension separation. This set-up was shown to possess powerful separation capabilities allowing separating as much as 89 different metabolites in a single sample. Identification and grouping of metabolites according to their chemical class were achieved using the DAD, MS and MS/MS data. Triterpene saponins were the most abundant metabolites followed by glycosylated flavanones and chalcones, whereas glycyrrhizic acid, as expected, was confirmed as the main component in all the studied samples. LC × LC-DAD-MS/MS was able to resolve these complex licorice samples providing with specific metabolite profiles to the different licorice samples depending on their geographical origin. Namely, from 19 to 50 specific compounds were exclusively determined in the 2D-chromatograms from the different licorice samples depending on their geographical origin, which can be used as a typical pattern that could potentially be related to their geographical location and authentication.

  3. Investigation of interpolation techniques for the reconstruction of the first dimension of comprehensive two-dimensional liquid chromatography-diode array detector data.

    Science.gov (United States)

    Allen, Robert C; Rutan, Sarah C

    2011-10-31

    Simulated and experimental data were used to measure the effectiveness of common interpolation techniques during chromatographic alignment of comprehensive two-dimensional liquid chromatography-diode array detector (LC×LC-DAD) data. Interpolation was used to generate a sufficient number of data points in the sampled first chromatographic dimension to allow for alignment of retention times from different injections. Five different interpolation methods, linear interpolation followed by cross correlation, piecewise cubic Hermite interpolating polynomial, cubic spline, Fourier zero-filling, and Gaussian fitting, were investigated. The fully aligned chromatograms, in both the first and second chromatographic dimensions, were analyzed by parallel factor analysis to determine the relative area for each peak in each injection. A calibration curve was generated for the simulated data set. The standard error of prediction and percent relative standard deviation were calculated for the simulated peak for each technique. The Gaussian fitting interpolation technique resulted in the lowest standard error of prediction and average relative standard deviation for the simulated data. However, upon applying the interpolation techniques to the experimental data, most of the interpolation methods were not found to produce statistically different relative peak areas from each other. While most of the techniques were not statistically different, the performance was improved relative to the PARAFAC results obtained when analyzing the unaligned data.

  4. Characterization and quantification of histidine degradation in therapeutic protein formulations by size exclusion-hydrophilic interaction two dimensional-liquid chromatography with stable-isotope labeling mass spectrometry.

    Science.gov (United States)

    Wang, Chunlei; Chen, Sike; Brailsford, John A; Yamniuk, Aaron P; Tymiak, Adrienne A; Zhang, Yingru

    2015-12-24

    Two dimensional liquid chromatography (2D-LC) coupling size exclusion (SEC) and hydrophilic interaction chromatography (HILIC) is demonstrated as a useful tool to study polar excipients, such as histidine and its degradant, in protein formulation samples. The SEC-HILIC setup successfully removed interferences from complex sample matrices and enabled accurate mass measurement of the histidine degradation product, which was then determined to be trans-urocanic acid. Because the SEC effluent is a strong solvent for the second dimension HILIC, experimental parameters needed to be carefully chosen, i.e., small transferring loop, fast gradient at high flow rates for the second dimension gradient, in order to mitigate the solvent mismatch and to ensure good peak shapes for HILIC separations. In addition, the generation of trans-urocanic acid was quantified by single heart-cutting SEC-HILIC 2D-LC combined with stable-isotope labeling mass spectrometry. Compared with existing 2D quantification methods, the proposed approach is fast, insensitive to solvent mismatch between dimensions, and tolerant of small retention time shifts in the first dimension. Finally, the first dimension diode array detector was found to be a potential degradation source for photolabile analytes such as trans-urocanic acid.

  5. Application of adjustment calculus in the nodeless Trefftz method for a problem of two-dimensional temperature field of the boiling liquid flowing in a minichannel

    Directory of Open Access Journals (Sweden)

    Hożejowska Sylwia

    2014-03-01

    Full Text Available The paper presents application of the nodeless Trefftz method to calculate temperature of the heating foil and the insulating glass pane during continuous flow of a refrigerant along a vertical minichannel. Numerical computations refer to an experiment in which the refrigerant (FC-72 enters under controlled pressure and temperature a rectangular minichannel. Initially its temperature is below the boiling point. During the flow it is heated by a heating foil. The thermosensitive liquid crystals allow to obtain twodimensional temperature field in the foil. Since the nodeless Trefftz method has very good performance for providing solutions to such problems, it was chosen as a numerical method to approximate two-dimensional temperature distribution in the protecting glass and the heating foil. Due to known temperature of the refrigerant it was also possible to evaluate the heat transfer coefficient at the foil-refrigerant interface. For expected improvement of the numerical results the nodeless Trefftz method was combined with adjustment calculus. Adjustment calculus allowed to smooth the measurements and to decrease the measurement errors. As in the case of the measurement errors, the error of the heat transfer coefficient decreased.

  6. Fingerprinting of traditional Chinese medicines on the C18-Diol mixed-mode column in online or offline two-dimensional liquid chromatography on the single column modes.

    Science.gov (United States)

    Wang, Qing; Tong, Ling; Yao, Lin; Zhang, Peng; Xu, Li

    2016-06-01

    In the present study, a mixed-mode stationary phase, C18-Diol, was applied for fingerprint analysis of traditional Chinese medicines. Hydrophobic, hydrogen bonding and electrostatic interactions were demonstrated to contribute the retention separately or jointly, which endowed the C18-Diol stationary phase with distinct selectivity compared to the bare C18 one. The separation of total alkaloids extracted from Fritillaria hupehensis was compared on the C18-Diol and conventional C18 column with the greater resolving power and better symmetry responses on the former one. Besides, a novel two-dimensional liquid chromatography on the single column (2D-LC-1C) was realized on C18-Diol with the offline mode for the alcohol extract of Fritillaria hupehensis and online mode for Ligusticum chuanxiong Hort. The early co-eluted extracted components with great polarity on the first dimension were reinjected on the same column and well separated on the second dimension. The results exhibited that the two complementary RPLC and HILIC modes on C18-Diol stationary phase enhanced the separation capacity and revealed more abundant chemical information of the sample, which was a powerful tool in analyzing complex herbal medicines.

  7. Identifying important structural features of ionic liquid stationary phases for the selective separation of nonpolar analytes by comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Zhang, Cheng; Ingram, Isaiah C; Hantao, Leandro W; Anderson, Jared L

    2015-03-20

    A series of dicationic ionic liquid (IL)-based stationary phases were evaluated as secondary columns in comprehensive two-dimensional gas chromatography (GC×GC) for the separation of aliphatic hydrocarbons from kerosene. In order to understand the role that structural features of ILs play on the selectivity of nonpolar analytes, the solvation parameter model was used to probe the solvation properties of the IL-based stationary phases. It was observed that room temperature ILs containing long free alkyl side chain substituents and long linker chains between the two cations possess less cohesive forces and exhibited the highest resolution of aliphatic hydrocarbons. The anion component of the IL did not contribute significantly to the overall separation, as similar selectivities toward aliphatic hydrocarbons were observed when examining ILs with identical cations and different anions. In an attempt to further examine the separation capabilities of the IL-based GC stationary phases, columns of the best performing stationary phases were prepared with higher film thickness and resulted in enhanced selectivity of aliphatic hydrocarbons.

  8. Lipid profiling of cyanobacteria Synechococcus sp. PCC 7002 using two-dimensional liquid chromatography with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Shan, Yabing; Liu, Yiqun; Yang, Li; Nie, Honggang; Shen, Sensen; Dong, Chunxia; Bai, Yu; Sun, Qing; Zhao, Jindong; Liu, Huwei

    2016-10-01

    Glycerolipid is a main component of membranes in oxygenic photosynthetic organisms. Up to now, the majority of publication in this area has focused on the physiological functions of glycerolipids and lipoprotein complexes in photosynthesis, but the study on the separation and identification of glycerolipids in thylakoid membrane in cyanobacteria is relatively rare. Here we report a new method to separate and identify five photosynthetic glycerolipid classes, including monoglucosyl diacylglycerol, monogalactosyl diacylglycerol, digalactosyl diacylglycerol, sulfoquinovosyl diacylglycerol, and phosphatidylglycerol, in cyanobacteria Synechococcus sp. PCC 7002 by two-dimensional (normal- and reversed-phase) liquid chromatography online coupled to quadrupole time-of-flight mass spectrometry. Over twice as many lipid species were detected by our method compared to the previously reported methods. Ten new odd-chain fatty acid glycerolipids were discovered for the first time. Moreover, complete separation of isomers of monogalactosyl diacylglycerol and monoglucosyl diacylglycerol was achieved. According to the tandem mass spectrometry results, we found that the head group of monoglucosyl diacylglycerols was not as stable as that of monogalactosyl diacylglycerols, which might explain why the organism chose monogalactosyl diacylglycerols and digalactosyl diacylglycerols instead of monoglucosyl diacylglycerols as the main content of the photosynthetic membranes in the history of evolution. This work will benefit further research on the physiological function of glycerolipids.

  9. Screening of cannabinoids in industrial-grade hemp using two-dimensional liquid chromatography coupled with acidic potassium permanganate chemiluminescence detection.

    Science.gov (United States)

    Pandohee, Jessica; Holland, Brendan J; Li, Bingshan; Tsuzuki, Takuya; Stevenson, Paul G; Barnett, Neil W; Pearson, James R; Jones, Oliver A H; Conlan, Xavier A

    2015-06-01

    Widely known for its recreational use, the cannabis plant also has the potential to act as an antibacterial agent in the medicinal field. The analysis of cannabis plants/products in both pharmacological and forensic studies often requires the separation of compounds of interest and/or accurate identification of the whole cannabinoid profile. In order to provide a complete separation and detection of cannabinoids, a new two-dimensional liquid chromatography method has been developed using acidic potassium permanganate chemiluminescence detection, which has been shown to be selective for cannabinoids. This was carried out using a Luna 100 Å CN column and a Poroshell 120 EC-C18 column in the first and second dimensions, respectively. The method has utilized a large amount of the available separation space with a spreading angle of 48.4° and a correlation of 0.66 allowing the determination of more than 120 constituents and mass spectral identification of ten cannabinoids in a single analytical run. The method has the potential to improve research involved in the characterization of sensitive, complex matrices.

  10. Analysis of spatial correlations in a model two-dimensional liquid through eigenvalues and eigenvectors of atomic-level stress matrices.

    Science.gov (United States)

    Levashov, V A; Stepanov, M G

    2016-01-01

    Considerations of local atomic-level stresses associated with each atom represent a particular approach to address structures of disordered materials at the atomic level. We studied structural correlations in a two-dimensional model liquid using molecular dynamics simulations in the following way. We diagonalized the atomic-level stress tensor of every atom and investigated correlations between the eigenvalues and orientations of the eigenvectors of different atoms as a function of distance between them. It is demonstrated that the suggested approach can be used to characterize structural correlations in disordered materials. In particular, we found that changes in the stress correlation functions on decrease of temperature are the most pronounced for the pairs of atoms with separation distance that corresponds to the first minimum in the pair density function. We also show that the angular dependencies of the stress correlation functions previously reported by Wu et al. [Phys. Rev. E 91, 032301 (2015)10.1103/PhysRevE.91.032301] do not represent the anisotropic Eshelby's stress fields, as it is suggested, but originate in the rotational properties of the stress tensors.

  11. Development of simulation approach for two-dimensional chiral molecular self-assembly driven by hydrogen bond at the liquid/solid interface

    Science.gov (United States)

    Qin, Yuan; Yao, Man; Hao, Ce; Wan, Lijun; Wang, Yunhe; Chen, Ting; Wang, Dong; Wang, Xudong; Chen, Yonggang

    2017-09-01

    Two-dimensional (2D) chiral self-assembly system of 5-(benzyloxy)-isophthalic acid derivative/(S)-(+)-2-octanol/highly oriented pyrolytic graphite was studied. A combined density functional theory/molecular mechanics/molecular dynamics (DFT/MM/MD) approach for system of 2D chiral molecular self-assembly driven by hydrogen bond at the liquid/solid interface was thus proposed. Structural models of the chiral assembly were built on the basis of scanning tunneling microscopy (STM) images and simplified for DFT geometry optimization. Merck Molecular Force Field (MMFF) was singled out as the suitable force field by comparing the optimized configurations of MM and DFT. MM and MD simulations for hexagonal unit model which better represented the 2D assemble network were then preformed with MMFF. The adhesion energy, evolution of self-assembly process and characteristic parameters of hydrogen bond were obtained and analyzed. According to the above simulation, the stabilities of the clockwise and counterclockwise enantiomorphous networks were evaluated. The calculational results were supported by STM observations and the feasibility of the simulation method was confirmed by two other systems in the presence of chiral co-absorbers (R)-(-)-2-octanol and achiral co-absorbers 1-octanol. This theoretical simulation method assesses the stability trend of 2D enantiomorphous assemblies with atomic scale and can be applied to the similar hydrogen bond driven 2D chirality of molecular self-assembly system.

  12. Ultra resolution chemical fingerprinting of dense non-aqueous phase liquids from manufactured gas plants by reversed phase comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    McGregor, Laura A; Gauchotte-Lindsay, Caroline; Daéid, Niamh Nic; Thomas, Russell; Daly, Paddy; Kalin, Robert M

    2011-07-22

    Ultra resolution chemical fingerprinting of dense non-aqueous phase liquids (DNAPLs) from former manufactured gas plants (FMGPs) was investigated using comprehensive two-dimensional gas chromatography coupled with time of flight mass spectrometry (GC×GC TOFMS). Reversed phase GC×GC (i.e. a polar primary column coupled to a non-polar secondary column) was found to significantly improve the separation of polycyclic aromatic hydrocarbons (PAHs) and their alkylated homologues. Sample extraction and cleanup was performed simultaneously using accelerated solvent extraction (ASE), with recovery rates between 76% and 97%, allowing fast, efficient extraction with minimal solvent consumption. Principal component analysis (PCA) of the GC×GC data was performed in an attempt to differentiate between twelve DNAPLs based on their chemical composition. Correlations were discovered between DNAPL composition and historic manufacturing processes used at different FMGP sites. Traditional chemical fingerprinting methods generally follow a tiered approach with sample analysis on several different instruments. We propose ultra resolution chemical fingerprinting as a fast, accurate and precise method of obtaining more chemical information than traditional tiered approaches while using only a single analytical technique.

  13. [Measurement of 11 benzophenone ultraviolet-filters in cosmetics by high performance liquid chromatography].

    Science.gov (United States)

    Qu, Baocheng; Bian, Haitao; Mao, Xiqin; Li, Jin

    2015-12-01

    A sample preparation and analytical method with liquid-liquid extraction (LLE) and high performance liquid chromatography (HPLC) was developed to detect 11 benzophenone ultraviolet-filters in cosmetics. The target compounds were extracted by the mixed solutions of tetrahydrofuran (TH)/methanol/water or dichloromethane/water at proper ratios. The extracts were centrifuged and filtered to remove matrix compounds, and then analyzed by HPLC. The separation of analytes was carried out on a Diamonsil-C18 column (150 mm x 4.6 mm, 5 μm) with 0.1% (v/v) formic acid aqueous solution (containing 10 mmol/L ammonium acetate) as mobile phase A and methanol containing 0.1% (v/v) formic acid as mobile phase B. The spiked recoveries of the method (n = 7) were 93.4%-103.8% with the relative standard deviations of 0.1%-4.2%. The limits of detection (LODs) were in the range of 4.0-30 μg/g and the limits of quantitation (LOQs) ranged from 15 to 100 μg/g. The method was applied to the determination of 42 cosmetic samples randomly purchased from the supermarket in Dalian. Five benzophenone series were always detected, in which the content of benzophenone-3 in sunscreen cream and the content of benzophenone-2 in perfume were very high and reached 2 785 μg/g and 2 106 μg/g, respectively. The results showed that the developed method is efficient, reliable and sensitive, which can be applied to the determination of benzophenones in cosmetics.

  14. Crosslinked structurally-tuned polymeric ionic liquids as stationary phases for the analysis of hydrocarbons in kerosene and diesel fuels by comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Zhang, Cheng; Park, Rodney A; Anderson, Jared L

    2016-04-01

    Structurally-tuned ionic liquids (ILs) have been previously applied as the second dimension column in comprehensive two-dimensional gas chromatography (GC×GC) and have demonstrated high selectivity in the separation of individual aliphatic hydrocarbons from other aliphatic hydrocarbons. However, the maximum operating temperatures of these stationary phases limit the separation of analytes with high boiling points. In order to address this issue, a series of polymeric ionic liquid (PIL)-based stationary phases were prepared in this study using imidazolium-based IL monomers via in-column free radical polymerization. The IL monomers were functionalized with long alkyl chain substituents to provide the needed selectivity for the separation of aliphatic hydrocarbons. Columns were prepared with different film thicknesses to identify the best performing stationary phase for the separation of kerosene. The bis[(trifluoromethyl)sulfonyl]imide ([NTf2](-))-based PIL stationary phase with larger film thickness (0.28μm) exhibited higher selectivity for aliphatic hydrocarbons and showed a maximum allowable operating temperature of 300°C. PIL-based stationary phases containing varied amount of IL-based crosslinker were prepared to study the effect of the crosslinker on the selectivity and thermal stability of the resulting stationary phase. The optimal resolution of aliphatic hydrocarbons was achieved when 50% (w/w) of crosslinker was incorporated into the PIL-based stationary phase. The resulting stationary phase exhibited good selectivity for different groups of aliphatic hydrocarbons even after being conditioned at 325°C. Finally, the crosslinked PIL-based stationary phase was compared with SUPELCOWAX 10 and DB-17 columns for the separation of aliphatic hydrocarbons in diesel fuel. Better resolution of aliphatic hydrocarbons was obtained when employing the crosslinked PIL-based stationary phase as the second dimension column.

  15. Characterization of therapeutic antibodies and related products by two-dimensional liquid chromatography coupled with UV absorbance and mass spectrometric detection.

    Science.gov (United States)

    Stoll, Dwight; Danforth, John; Zhang, Kelly; Beck, Alain

    2016-10-01

    The development of analytical tools for the characterization of large biomolecules is an emerging and rapidly evolving area. This development activity is motivated largely by the current trend involving the increase in development and use of large biomolecules for therapeutic uses. Given the inherent complexity of these biomolecules, which arises from their sheer size and possibilities for chemical modification as well as changes over time (e.g., through modification in solution, aggregation), two-dimensional liquid chromatography (2D-LC) has attracted considerable interest as an analytical tool to address the challenges faced in characterizing these materials. The immediate potential benefits of 2D-LC over conventional one-dimensional liquid chromatography in this context include: (1) higher overall resolving power; (2) complementary information gained from two dimensions of separation in a single analysis; and (3) enabling indirect coupling of separation modes that are inherently incompatible with mass spectrometric (MS) detection (e.g., ion-exchange, because of high-salt eluents) to MS through a more compatible second dimension separation such as reversed-phase LC. In this review we summarize the work in this area, most of which has occurred in the past five years. Although the future is bright for further development in this area, some challenges have already been addressed through new 2D-LC methods. These include: (1) deep characterization of monoclonal antibodies to understand charge heterogeneity, glycosylation patterns, and other modifications; (2) characterization of antibody-drug conjugates to understand the extent and localization of small molecule conjugation; (3) detailed study of excipients in protein drug formulations; and (4) detection of host-cell proteins on biotherapeutic molecule preparations. We fully expect that in the near future we will see this list expanded, and that continued development will lead to methods with further improved

  16. Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ovchinnikova, Olga S [ORNL; Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

    2011-01-01

    This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of this coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.

  17. Quantitative Analysis of Sphingomyelin by High-Performance Liquid Chromatography after Enzymatic Hydrolysis

    Directory of Open Access Journals (Sweden)

    Seunghyun Lee

    2012-01-01

    Full Text Available Sphingomyelin is the most abundant sphingolipid in mammalian cells and is mostly present in the plasma membrane. A new analytical method using high-performance liquid chromatography (HPLC was developed to quantify sphingomyelin in mouse plasma and tissues, 3T3-L1 cells, rat aortic smooth muscle cells, and HT-29 cells. Sphingomyelin and dihydrosphingomyelin, an internal standard, were separated by high-performance thin-layer chromatography and simultaneously hydrolyzed with sphingolipid ceramide N-deacylase and sphingomyelinase to release sphingosine and dihydrosphingosine, respectively. Sphingomyelin content was measured by HPLC following o-phthalaldehyde derivatization. Sphingomyelin concentrations in 3T3-L1 cells, rat aortic smooth muscle cells, and HT-29 cells were 60.10±0.24, 62.69±0.08, and 58.38±0.37 pmol/μg protein, respectively, whereas those in brain, kidney, and liver of ICR mice were 55.60±0.43, 43.75±0.21, and 22.26±0.14 pmol/μg protein. The sphingomyelin concentration in mouse plasma was 407.40±0.31 μM. The limits of detection and quantification for sphingomyelin were 5 and 20 pmol, respectively, in the HPLC analysis with fluorescence detection. This sensitivity was sufficient for analyzing sphingomyelin in biological samples. In conclusion, this analytical method is a sensitive and specific technique for quantifying sphingomyelin and was successfully applied to diverse biological samples with excellent reproducibility.

  18. Two-dimensional capillary origami

    Science.gov (United States)

    Brubaker, N. D.; Lega, J.

    2016-01-01

    We describe a global approach to the problem of capillary origami that captures all unfolded equilibrium configurations in the two-dimensional setting where the drop is not required to fully wet the flexible plate. We provide bifurcation diagrams showing the level of encapsulation of each equilibrium configuration as a function of the volume of liquid that it contains, as well as plots representing the energy of each equilibrium branch. These diagrams indicate at what volume level the liquid drop ceases to be attached to the endpoints of the plate, which depends on the value of the contact angle. As in the case of pinned contact points, three different parameter regimes are identified, one of which predicts instantaneous encapsulation for small initial volumes of liquid.

  19. Two-dimensional capillary origami

    Energy Technology Data Exchange (ETDEWEB)

    Brubaker, N.D., E-mail: nbrubaker@math.arizona.edu; Lega, J., E-mail: lega@math.arizona.edu

    2016-01-08

    We describe a global approach to the problem of capillary origami that captures all unfolded equilibrium configurations in the two-dimensional setting where the drop is not required to fully wet the flexible plate. We provide bifurcation diagrams showing the level of encapsulation of each equilibrium configuration as a function of the volume of liquid that it contains, as well as plots representing the energy of each equilibrium branch. These diagrams indicate at what volume level the liquid drop ceases to be attached to the endpoints of the plate, which depends on the value of the contact angle. As in the case of pinned contact points, three different parameter regimes are identified, one of which predicts instantaneous encapsulation for small initial volumes of liquid. - Highlights: • Full solution set of the two-dimensional capillary origami problem. • Fluid does not necessarily wet the entire plate. • Global energy approach provides exact differential equations satisfied by minimizers. • Bifurcation diagrams highlight three different regimes. • Conditions for spontaneous encapsulation are identified.

  20. Ionic Liquid-based Microwave-assisted Liquid-liquid Microextraction and High Performance Liquid Chromatography Determination of Sulfonamides from Animal Oils

    Institute of Scientific and Technical Information of China (English)

    FENG Xu-dong; LIANG Fang-hui; SU Rui; WU Li-jie; LI Xue-yuan; WANG Xing-hua; ZHANG Han-qi

    2013-01-01

    The authors performed ionic liquid-based microwave-assisted liquid-liquid microextraction(IL-based MALLME) coupled with high performance liquid chromatographic separation for the determination of 6 sulfonamides (SAs) from animal oils.The target analytes were extracted from animal oil samples with sodium hydroxide solution containing 1-butyl-3-methylimidazolium tetrafluoroborateand as the extraction solvent under microwave irradiation.The experimental parameters of the IL-based MALLME,including types of ILs,volume of IL,amount of ion-pairing agent(NH4PF6),pH value of sample solution,and extraction temperature and time were evaluated.The limits of detection and quantification obtained were in a range of 0.4-0.5 μg/kg and a range of 1.2-1.8 μg/kg,respectively.The accuracy of the method was evaluated by analyzing five spiked animal oil samples at two fortified levels(5 and 50 μg/kg),and the recoveries of SAs varied from 81.4% to 114.5% with relative standard deviations ranging from 0.8% to 9.0%.

  1. Quantitation of antioxidants in water samples using ionic liquid dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection.

    Science.gov (United States)

    Sobhi, Hamid Reza; Kashtiaray, Amir; Farahani, Hadi; Farahani, Mohammad Reza

    2011-01-01

    A simple and efficient method, ionic liquid-based dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV), has been applied for the extraction and determination of some antioxidants (Irganox 1010, Irganox 1076 and Irgafos 168) in water samples. The microextraction efficiency factors were investigated and optimized: 1-hexyl-3-methylimidazolium hexafluorophosphate [C(6)MIM][PF(6)] (0.06 g) as extracting solvent, methanol (0.5 mL) as disperser solvent without salt addition. Under the selected conditions, enrichment factors up to 48-fold, limits of detection (LODs) of 5.0-10.0 ng/mL and dynamic linear ranges of 25-1500 ng/mL were obtained. A reasonable repeatability (RSD≤11.8%, n=5) with satisfactory linearity (r(2)≥0.9954) of the results illustrated a good performance of the presented method. The accuracy of the method was tested by the relative recovery experiments on spiked samples, with results ranging from 85 to 118%. Finally, the method was successfully applied for determination of the analytes in several real water samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy.

    Science.gov (United States)

    Markovic, Miljenko; Stathakis, Sotirios; Mavroidis, Panayiotis; Jurkovic, Ines-Ana; Papanikolaou, Nikos

    2014-05-01

    The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. The device used in this study was Octavius 1000 SRS model (PTW, Freiburg, Germany). Its 2D array of detectors consists of 977 liquid-filled ion chambers arranged over an area of 11 × 11 cm. The size of the detectors is 2.3 × 2.3 × 0.5 mm (volume of 0.003 cm(3)) and their spacing in the inner area of 5.5 × 5.5 cm is 2.5 mm center-to-center, whereas in the outer area it is 5 mm center-to-center. The detector reproducibility, dose linearity, and sensitivity to positional changes of the collimator were tested. Also, the output factors of field sizes ranging from 0.5 × 0.5 to 10 × 10 cm(2) both for open and wedged fields have been measured and compared against those measured by a pin-point ionization chamber, liquid filled microchamber, SRS diode, and EDR2 film. Its short-term reproducibility was within 0.2% and its medium and long-term reproducibility was within 0.5% (verified with air ionization chamber absolute dose measurements), which is an excellent result taking into account the daily fluctuation of the linear accelerator and the errors in the device setup reproducibility. The dose linearity and dose rate dependence were measured in the range of 0.5-85 Gy and 0.5-10 Gy min(-1), respectively, and were verified with air ionization chamber absolute dose measurements was within 3%. The measurements of the sensitivity showed that the 2D Array could detect millimetric collimator positional changes. The measured output factors showed an agreement of better than 0.3% with the pinpoint chamber and microliquid filled chamber for the field sizes between 3 × 3 and 10 × 10 cm(2). For field sizes down to 1 × 1 cm(2), the agreement with SRS diode and microliquid filled chamber is better than 2%. The measurements of open and

  3. Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, Miljenko, E-mail: markovic@livemail.uthscsa.edu; Stathakis, Sotirios; Mavroidis, Panayiotis; Jurkovic, Ines-Ana; Papanikolaou, Nikos [Department of Radiation Oncology, University of Texas Health Sciences Center at San Antonio, San Antonio, Texas 78229 (United States)

    2014-05-15

    Purpose: The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. Methods: The device used in this study was Octavius 1000 SRS model (PTW, Freiburg, Germany). Its 2D array of detectors consists of 977 liquid-filled ion chambers arranged over an area of 11 × 11 cm. The size of the detectors is 2.3 × 2.3 × 0.5 mm (volume of 0.003 cm{sup 3}) and their spacing in the inner area of 5.5 × 5.5 cm is 2.5 mm center-to-center, whereas in the outer area it is 5 mm center-to-center. The detector reproducibility, dose linearity, and sensitivity to positional changes of the collimator were tested. Also, the output factors of field sizes ranging from 0.5 × 0.5 to 10 × 10 cm{sup 2} both for open and wedged fields have been measured and compared against those measured by a pin-point ionization chamber, liquid filled microchamber, SRS diode, and EDR2 film. Results: Its short-term reproducibility was within 0.2% and its medium and long-term reproducibility was within 0.5% (verified with air ionization chamber absolute dose measurements), which is an excellent result taking into account the daily fluctuation of the linear accelerator and the errors in the device setup reproducibility. The dose linearity and dose rate dependence were measured in the range of 0.5–85 Gy and 0.5–10 Gy min{sup −1}, respectively, and were verified with air ionization chamber absolute dose measurements was within 3%. The measurements of the sensitivity showed that the 2D Array could detect millimetric collimator positional changes. The measured output factors showed an agreement of better than 0.3% with the pinpoint chamber and microliquid filled chamber for the field sizes between 3 × 3 and 10 × 10 cm{sup 2}. For field sizes down to 1 × 1 cm{sup 2}, the agreement with SRS diode and microliquid filled

  4. Evaluation of aminoacids in irradiated beans (Vigna unguiculata (L.) Walp) by high performance liquid chromatography (HPLC)

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Keila S. Cople; Souza, Luciana B.; Coelho, Maysa J.; Lima, Antonio L. Santos; Hernandes, Nilber K. [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Secao de Engenharia Nuclear]. E-mail: keila@ime.eb.br; Godoy, Ronoel L.O. [EMBRAPA Agroindustria de Alimentos, Rio de Janeiro, RJ (Brazil)]. E-mail: ronoel@ctaa.embrapa.br

    2007-07-01

    Fradinho-bean (Vigna unguiculata (L.) Walp) is originated from Africa and is known in Brazil as 'caupi', 'corda' or 'macassar'. It is grown in the interior of Northeast Brazil (semi-arid region) and can be found in parts of the North, being one of the most important components of people's diet in those regions. The Northeast area produces around 429,375 ton of fradinho-bean per year. Leguminous plants are very important sources of proteins, vitamins, carbohydrates and minerals. This kind of bean is an excellent source of proteins (around 23- 25% of its nutritional content), being superior to regular beans (Phaseolus vulgaris). The irradiation process is an alternative to avoid post-harvesting losses, without changing the nutritional value of food. This study has the objective to evaluate the effect of different gamma irradiation doses (0.0; 0.5; 1.0; 2.5; 5.0 and 10.0 kGy) on aminoacid content of fradinho-bean by high performance liquid chromatography (HPLC) and the accompanying of the grains during storage time of 6 months. After irradiation, the bean grains went through a milling process in order to make flour for posterior extraction. A liquid chromatographer Waters, model Alliance 2695, with fluorescent detector Waters 2475, having a mobile phase with gradient elution of sodium acetate. acetonitrile and Milli-Q water, was employed. The flux used was 1 mL/min and the injection volume of 10 {mu}L. The column (C 18 150.0 x 3.9 mm) was kept at 36 deg C. The results show that gamma irradiation is a promise process for fradinho bean during conservation storage time of 6 months, until the dose of 10.0 kGy. Even the most radio-sensitive aminoacids like aromatics and basic lateral chains were preserved. (author)

  5. High-performance liquid chromatography determination of dipotassium clorazepate and its major metabolite nordiazepam in plasma.

    Science.gov (United States)

    Colin, P; Sirois, G; Lelorier, J

    1983-04-08

    A rapid and sensitive high-performance liquid chromatographic method is described for the quantitative analysis of dipotassium clorazepate (CZP) and its major metabolite nordiazepam (ND) in fresh human and dog plasma. The method consists of two separate selective ND extractions from a plasma sample without and with conversion of all the CZP to ND. For quantitation, diazepam (DZP) is used as the internal standard. The chromatographic phase utilized in a reversed-phase Hibar EC-RT analytical column prepacked with LiChrosolv RP-18 with a solvent system consisting of acetonitrile-0.05 M sodium acetate buffer, pH 5.0 (45:55). The UV absorbance is monitored at 225 nm using a variable-wavelength detector. The mean assay coefficient of variation over a concentration range of 20-400 ng per ml of plasma is less than 3% for the within-day precision. Recoveries of ND, DZP and CZP (as ND) are essentially quantitative at all levels investigated. The calibration curves of ND are rectilinear (r2 = 0.99) from the lower limit of sensitivity (2 ng/ml) to at least 2000 ng/ml in plasma. Applicability of the method to CZP and ND disposition studies in the anaesthetized mongrel dog is illustrated. When the two separate selective nordiazepam extractions from plasma cannot be performed immediately after blood sampling, an extrapolation kinetic method is suggested for the estimation of CZP concentration. In all previous in vivo studies, CZP has been determined only with gas-liquid chromatographic methods.

  6. Simultaneous determination of tolperisone and lidocaine by high performance liquid chromatography.

    Science.gov (United States)

    Liawruangrath, S; Liawruangrath, B; Pibool, P

    2001-12-01

    A reversed phase high performance liquid chromatographic (RP-HPLC) method for the simultaneous determination of tolperisone (TP) and lidocaine (LD) has been developed. The drugs were separated on a column (4.60 x 250 mm(2)) Spherisorb ODS (5 microm) using 5.5% triethylamine in 70/30 v/v acetonitrile/water as mobile phase 0.7 ml min(-1)and UV detection at 254 nm. The detection limits for Tolperisone hydrochloride (TP-HCl) and lidocaine hydrochloride (LD-HCl) were 0.20 ng/20 microl and 100 ng/20 microl and the quantitation limits were 0.50 ng/20 microl and 250 ng/20 microl, respectively. Linear calibration curves over the ranges of 1-10, 10-100 and 150-500 microg ml(-1) for TP-HCl and 10-500 microg ml(-1) for LD-HCl were established. Different calibration slopes were found for TP probably owing to changes in refractive index due to increase in TP concentration. The average recoveries of the added TP in the samples (TP-HCl tablets and injection liquid). A solutions spiked with standard TP-HCl were 99.9 and 99.7% with the RSD (n=11) of 0.66 and 0.67%, respectively. The average recovery of the added LD in the sample (injection) spiked with standard LD-HCl was 98.9% with the RSD (n=11) of 0.59%. The proposed method has been applied to the determination of TP-HCl and LD-HCl in commercial products available in Thailand. Comparative determination of TP by UV spectrophotometry and LD by colorimetry were also carried out. The results obtained by both methods were in good agreement of those obtained by the proposed method verified by using t-test. The proposed RP-HPLC method is simple, accurate, reproducible and suitable for routine analysis.

  7. Determination of diflubenzuron and chlorbenzuron in fruits by combining acetonitrile-based extraction with dispersive liquid-liquid microextraction followed by high-performance liquid chromatography.

    Science.gov (United States)

    Ruan, Chunqiang; Zhao, Xiang; Liu, Chenglan

    2015-09-01

    In this study, a simple and low-organic-solvent-consuming method combining an acetonitrile-partitioning extraction procedure followed by "quick, easy, cheap, effective, rugged and safe" cleanup with ionic-liquid-based dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection was developed for the determination of diflubenzuron and chlorbenzuron in grapes and pears. Ionic-liquid-based dispersive liquid-liquid microextraction was performed using the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate as the extractive solvent and acetonitrile extract as the dispersive solvent. The main factors influencing the efficiency of the dispersive liquid-liquid microextraction were evaluated, including the extractive solvent type and volume and the dispersive solvent volume. The validation parameters indicated the suitability of the method for routine analyses of benzoylurea insecticides in a large number of samples. The relative recoveries at three spiked levels ranged between 98.6 and 109.3% with relative standard deviations of less than 5.2%. The limit of detection was 0.005 mg/kg for the two insecticides. The proposed method was successfully used for the rapid determination of diflubenzuron and chlorbenzuron residues in real fruit samples.

  8. [Determination of polyphenols in tobacco by solid phase extraction and high performance liquid chromatography].

    Science.gov (United States)

    Wang, L; Fang, R B; Li, Z; Jiang, C Q; Yang, G Y

    2001-11-01

    A high performance liquid chromatographic (HPLC) method for the determination of polyphenols in tobacco was studied. Polyphenols can be extracted from tobacco sample by refluxing with 80% (volume fraction) methanol, then subjected to degrease by solid phase extraction with Sep-Pak-C18 column. Chlorogenic acid, rutin, scopoletin, caffeic acid, scopolin and other polyphenols can be separated on a Nova-Pak-C18 column (3.9 mm i.d. x 150 mm) gradiently eluted with methanol and 0.05 mol.L-1 potassium dihydrogen phosphate buffer solution as mobile phase at a flow-rate of 0.5 mL.min-1. Polyphenols were determined at the maximum wavelength of each polyphenol, for chlorogenic acid 326.1 nm, rutin 354.8 nm, scopoletin 344.0 nm, caffeic acid 323.7 nm and scopolin 365.2 nm by photodiode array detector. The main polyphenols in tobacco can be identified with UV spectroscopy. The recoveries of tobacco polyphenols were 94%-105%, and the relative standard deviations were 1.28%-1.49%. This method can be applied to the determination of polyphenols in tobacco with satisfactory results.

  9. High-performance liquid chromatographic assay for metamizol metabolites in rat plasma: application to pharmacokinetic studies.

    Science.gov (United States)

    Domínguez-Ramírez, Adriana Miriam; Calzadilla, Patricia Carrillo; Cortés-Arroyo, Alma Rosa; Hurtado Y de la Peña, Marcela; López, José Raúl Medina; Gómez-Hernández, Martín; López-Muñoz, Francisco Javier

    2012-12-01

    In order to evaluate the pharmacokinetics of metamizol in the presence of morphine in arthritic rats, after subcutaneous administration of the drugs, an easy, rapid, sensitive and selective analytical method was proposed and validated. The four main metamizol metabolites (4-methylaminoantipyrine, 4-aminoantipyrine, 4-acetylaminoantipyrine and 4-formylaminoantipyrine) were extracted from plasma samples (50-100μl) by a single solid-phase extraction method prior to reverse-phase high performance liquid chromatography with diode-array detection. Standard calibration graphs for all metabolites were linear within a range of 1-100μg/ml (r(2)≥0.99). The intra-day coefficients of variation (CV) were in the range of 1.3-8.4% and the inter-day CV ranged from 1.5 to 8.4%. The intra-day assay accuracy was in the range of 0.6-9.6% and the inter-day assay accuracy ranged from 0.9 to 7.5% of relative error. The lower limit of quantification was 1μg/ml for all metabolites using a plasma sample of 100μl. Plasma samples were stable at least for 4 weeks at -20°C. This method was found to be suitable for studying metamizol metabolites pharmacokinetics in arthritic rats, after simultaneous administration of metamizol and morphine, in single dose. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Determination of aristolochic acids by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Wang, Yinan; Chan, Wan

    2014-06-25

    Nephrotoxic and carcinogenic aristolochic acids (AAs) are naturally occurring nitrophenanthrene carboxylic acids in the herbal genus Aristolochia. The misuse of AA-containing herbs in preparing slimming drugs has caused hundred of cases of kidney disease in Belgium women in a slimming regime in the early 1990s. Accumulating evidence also suggested that prolong dietary intake of AA-contaminated food is one of the major causes to the Balkan endemic nephropathy that was first observed in the late 1950s. Therefore, analytical methods of high sensitivity are extremely important for safeguarding human exposure to AA-containing herbal medicines, herbal remedies, and food composites. In this paper, we describe the development of a new high-performance liquid chromatography coupled fluorescence detector (HPLC-FLD) method for the sensitive determination of AAs. The method makes use of a novel cysteine-induced denitration reaction that "turns on" the fluorescence of AAs for fluorometric detections. Our results showed that the combination of cysteine-induced denitration and HPLC-FLD analysis allows for sensitive quantification of AA-I and AA-II at detection limits of 27.1 and 25.4 ng/g, respectively. The method was validated and has been successfully applied in quantifying AAs in Chinese herbal medicines.

  11. Determination of 5-methylcytosine from plant DNA by high-performance liquid chromatography.

    Science.gov (United States)

    Wagner, I; Capesius, I

    1981-06-26

    The relative amounts of the five nucleosides (deoxycytidine, 5-methyldeoxycytidine, deoxyadenosine, deoxyguanosine and thymidine) in the DNA of nine plant species, one plant satellite DNA, and one animal species were determined by high performance liquid chromatography. The method allows the clean separation of the nucleosides from 10 microgram samples with 15 min. The following values for the proportion of methylated cytosines among all cytosines were obtained: Lobularia maritima 18.5%, Nicotiana tabacum 32.6%, Pisum sativum 23.2%, Rhinanthus minor 29.2%, Sinapsis alba 12.2%, Vicia faba 30.5%, Viscum album 23.2%, Cymbidium pumilum 18.8%, Cymbidium pumilum AT-rich satellite DNA 15.8%, Triticum aestivum 22.4%. DNA of an animal, the gerbil, Meriones unguiculatus, had a methylation percentage of 3.1%. An estimate of the GC content based on the buoyant density of DNA tends to be lower than the actual value, an estimate based on the melting temperature tends to be higher. This supports the finding by other authors that DNA methylation decreases the buoyant density and may increase the melting temperature at high m5C concentration.

  12. Rapid estimation of concentration of aromatic classes in middistillate fuels by high-performance liquid chromatography

    Science.gov (United States)

    Otterson, D. A.; Seng, G. T.

    1985-01-01

    An high performance liquid chromatography (HPLC) method to estimate four aromatic classes in middistillate fuels is presented. Average refractive indices are used in a correlation to obtain the concentrations of each of the aromatic classes from HPLC data. The aromatic class concentrations can be obtained in about 15 min when the concentration of the aromatic group is known. Seven fuels with a wide range of compositions were used to test the method. Relative errors in the concentration of the two major aromatic classes were not over 10 percent. Absolute errors of the minor classes were all less than 0.3 percent. The data show that errors in group-type analyses using sulfuric acid derived standards are greater for fuels containing high concentrations of polycyclic aromatics. Corrections are based on the change in refractive index of the aromatic fraction which can occur when sulfuric acid and the fuel react. These corrections improved both the precision and the accuracy of the group-type results.

  13. Reversed-phase high-performance liquid chromatography of unsubstituted aminobenzoic acids

    Science.gov (United States)

    Abidi, S.L.

    1989-01-01

    High-performance liquid chromatographic (HPLC) characteristics of three position isomers of aminobenzoic acids (potential metabolites of important anesthetic drugs), were delineated with respect to their interactions with various mobile phases and stationary phases. HPLC with five hydrocarbonaceous phase, I?-cyclodextrin silica (CDS), macrophase MP-1 polymer (MP), macroporous polystyrene/divinylbenzene (MPD), octadecylsilica (ODS), and propylphenylsilica (PPS), yielded results explicable in terms of substituent effects derived from the bifunctional amino- and carboxy groups. For cases where mobile phases contained sulfonates or quaternary ammonium salts both having longer chain alkyls, retention of analytes on all but CDS appeared to proceed predominantly via an ion-pairing mechanism. The extent of the corresponding counter-ion effects decreased in the order: MPD > ODS > PPS > MP, while the analyte retention order paralleled thier pH2 values. On the other hand, an inverse relationship between the magnitude of capacity factors (k') and pK1 values of the title compounds was observed in experiments that produced retention data incompatible with ion-pair interaction rationales. The unique HPLC results obtained with the CDS phase are compared with those obtained with other phases.

  14. Sources of Variability in Chlorophyll Analysis by Fluorometry and by High Performance Liquid Chromatography. Chapter 22

    Science.gov (United States)

    VanHeukelem, Laurie; Thomas, Crystal S.; Glibert, Patricia M.

    2001-01-01

    The need for accurate determination of chlorophyll a (chl a) is of interest for numerous reasons. From the need for ground-truth data for remote sensing to pigment detection for laboratory experimentation, it is essential to know the accuracy of the analyses and the factors potentially contributing to variability and error. Numerous methods and instrument techniques are currently employed in the analyses of chl a. These methods range from spectrophotometric quantification, to fluorometric analysis and determination by high performance liquid chromatography. Even within the application of HPLC techniques, methods vary. Here we provide the results of a comparison among methods and provide some guidance for improving the accuracy of these analyses. These results are based on a round-robin conducted among numerous investigators, including several in the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) and HyCODE Programs. Our purpose here is not to present the full results of the laboratory intercalibration; those results will be presented elsewhere. Rather, here we highlight some of the major factors that may contribute to the variability observed. Specifically, we aim to assess the comparability of chl a analyses performed by fluorometry and HPLC, and we identify several factors in the analyses which may contribute disproportionately to this variability.

  15. High-performance liquid chromatography of quinoidal imminium compounds derived from triphenylmethanes

    Science.gov (United States)

    Abidi, S.L.

    1983-01-01

    A series of eleven p-aminotriphenylmethane dyes have been studied by high-performance liquid chromatography (HPLC). The combined use of HPLC and spectrophotometry permits specific detection of these compounds in the visible range around 600 nm. As the high affinity of the imminium cations for the active sites of the hydrocarbonaceous stationary phase has presented difficulties for reversed-phase HPLC with pure solvents, organic electrolytes were added to the mobile phase to facilitate the elution of the components with improved selectivity, sensitivity (minimum detection limit, 0.1 μg/ml), and peak symmetry. The effects of chromatographic variables on the component retentivity were investigated. Retention times of the dye analytes decreased with increasing concentration of the added ionic reagent and with decreasing number of the hydrophobic alkyl substituents on the nitrogen atom. The influence of pH on the retention parameters appears to parallel that observed previously for cationic quaternary ammonium compounds. Among the acidic reagents employed, naphthalenesulfonic acid yielded the most satisfactory results. The use of binary electrolyte systems invariably improved the chromatographic behavior of the imminium solutes analyzed. Results obtained with two different octadecylsilica columns have been compared.

  16. Chiral-phase high-performance liquid chromatography of rotenoid racemates

    Science.gov (United States)

    Abidi, S.L.

    1987-01-01

    The high-performance liquid chromatograhic (HPLC) behavior of parent rotenoids (type I) and the hydroxyl-analogues (type II) on three different chiral stationary phases (CSPs) was studied. Separations of optical isomers were achieved in various degrees depending largely upon the rotenoidal structures and the CSP types employed. Enantiomers of all but elliptone compounds were separable on β-cyclodextrin-bonded silica (CDS). Without exception, the 12a-hydroxyrotenoid antipodes were resolved on Pirkle's phenylglycine-bonded silica (PGS) despite unsuccessful attenmpts to resolve the type I rotenoidal racemates. Conversely, optical resolution of the latter rotenoids was accomplished by using a helical polytriphenylmethylacrylate-coated silica (TPS) column and the observed separation factors (α values) ranged from 1.14 to 1.90. The results from HPLC of type II rotenoids on TPS (α = 1.00–1.63) suggested that variations in E-ring structures had profound influence on the resolution outcome. Conjugated double bonds on the E-ring and the desisopropylation of the five-membered E-ring ot type II rotenoids appeared to be important structural features for chiral recognition involving the TPS substrate. In both reversed-phase (CDS) and normal-pahse (PGS and TPS) HPLC modes, the less polar enantiomers were the 6aβ,12aβ-rotenoids as observed in most cases, though this relationship was reversed in the cases of deguelin and hydroxyelliptone probably due to conformational effects of rotenoidal ring systems.

  17. Detection of HEMA in self-etching adhesive systems with high performance liquid chromatography

    Science.gov (United States)

    Panduric, V.; Tarle, Z.; Hameršak, Z.; Stipetić, I.; Matosevic, D.; Negovetić-Mandić, V.; Prskalo, K.

    2009-04-01

    One of the factors that can decrease hydrolytic stability of self-etching adhesive systems (SEAS) is 2-hydroxymethylmethacrylate (HEMA). Due to hydrolytic instability of acidic methacrylate monomers in SEAS, HEMA can be present even if the manufacturer did not include it in original composition. The aim of the study was to determine the presence of HEMA because of decomposition by hydrolysis of methacrylates during storage, resulting with loss of adhesion strength to hard dental tissues of the tooth crown. Three most commonly used SEAS were tested: AdheSE ONE, G-Bond and iBond under different storage conditions. High performance liquid chromatography analysis was performed on a Nucleosil C 18-100 5 μm (250 × 4.6 mm) column, Knauer K-501 pumps and Wellchrom DAD K-2700 detector at 215 nm. Data were collected and processed by EuroCrom 2000 HPLC software. Calibration curves were made related eluted peak area to known concentrations of HEMA (purchased from Fluka). The elution time for HEMA is 12.25 min at flow rate 1.0 ml/min. Obtained results indicate that no HEMA was present in AdheSE ONE because methacrylates are substituted with methacrylamides that seem to be more stable under acidic aqueous conditions. In all other adhesive systems HEMA was detected.

  18. Determination of Decabrominated Diphenyl Ether in Soils by Soxhlet Extraction and High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Xing-Jian Yang

    2013-01-01

    Full Text Available This study described the development of a method based on soxhlet extraction combining high performance liquid chromatography (soxhlet-HPLC for the accurate detection of BDE-209 in soils. The solvent effect of working standard solutions in HPLC was discussed. Results showed that 1 : 1 of methanol and acetone was the optimal condition which could totally dissolve the BDE-209 in environmental samples and avoid the decrease of the peak area and the peak deformation difference of BDE-209 in HPLC. The preliminary experiment was conducted on the configured grassland (1 μg/g to validate the method feasibility. The method produced reliable reproducibility, simulated soils (n=4 RSD 1.0%, and was further verified by the analysis e-waste contaminated soils, RSD range 5.9–11.4%. The contamination level of BDE-209 in burning site was consistent with the previous study of Longtang town but lower than Guiyu town, and higher concentration of BDE-209 in paddy field mainly resulted from the long-standing disassembling area nearby. This accurate and fast method was successfully developed to extract and analyze BDE-209 in soil samples, showing its potential use for replacing GC to determinate BDE-209 in soil samples.

  19. Quantitative structure-retention relationships of pesticides in reversed-phase high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Aschi, Massimiliano [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy); D' Archivio, Angelo Antonio [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy)]. E-mail: darchivi@univaq.it; Maggi, Maria Anna [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy); Mazzeo, Pietro [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy); Ruggieri, Fabrizio [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy)

    2007-01-23

    In this paper, a quantitative structure-retention relationships (QSRR) method is employed to predict the retention behaviour of pesticides in reversed-phase high-performance liquid chromatography (HPLC). A six-parameter nonlinear model is developed by means of a feed-forward artificial neural network (ANN) with back-propagation learning rule. Accurate description of the retention factors of 26 compounds including commonly used insecticides, herbicides and fungicides and some metabolites is successfully achieved. In addition to the acetonitrile content, included to describe composition of the water-acetonitrile mobile phase, the octanol-water partition coefficient (from literature) and four quantum chemical descriptors are considered to account for the effect of solute structure on the retention. These are: the total dipole moment, the mean polarizability, the anisotropy of polarizability and a descriptor of hydrogen bonding ability based on the atomic charges on hydrogen bond donor and acceptor chemical functionalities. The proposed nonlinear QSRR model exhibits a high degree of correlation between observed and computed retention factors and a good predictive performance in wide range of mobile phase composition (40-65%, v/v acetonitrile) that supports its application for the prediction of the chromatographic behaviour of unknown pesticides. A multilinear regression model based on the same six descriptors shows a significantly worse predictive capability.

  20. Description and validation of coupling high performance liquid chromatography with resonance Rayleigh scattering in aminoglycosides determination

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Lei [Chemistry and Chemical Engineering, Southwest University, 400715 Chongqing (China); Peng Jingdong, E-mail: hxpengjd@swu.edu.cn [Chemistry and Chemical Engineering, Southwest University, 400715 Chongqing (China); Tang Jinxia; Yuan Binfang; He Rongxing; Xiao Ying [Chemistry and Chemical Engineering, Southwest University, 400715 Chongqing (China)

    2011-11-14

    Graphical abstract: Theoretical and experimental analysis had proved that aminoglycosides reacted with Congo red to form binary compounds simultaneously, which led to a novel HPLC-RRS strategy being applied in substances which are not fluorescing and not UV absorbed. Highlights: {yields} A novel HPLC-RRS strategy was shown in this study. {yields} Theoretical and experimental analysis had proved the feasibility of this method. {yields} Because of its specificity, no interference from the matrix was observed. {yields} The analytes in biological matrix were all well resolved without any interference. {yields} It provided new insights for analytes lack of useful spectroscopic and electrochemical properties. - Abstract: In view of the fact that many substances generally exhibit very little ultraviolet absorbance and the absence of native fluorescence, a new strategy with simple instrumentation and excellent analytical performance combining high performance liquid chromatography (HPLC) with resonance Rayleigh scattering (RRS) was developed. It was validated for the quantification of aminoglycosides (AGs). This fact was also carefully calculated by quantum chemistry. However, the sensitivity was probably limited by the volume of flow-through cell. Therefore, the result calls for a suitable one to ensure optimal RRS signal. Interestingly, when serum or urine samples of analytes were analyzed by this method, they were all well resolved without any interference, which would hold a new perspective to be applied in the determination of substances in biological matrix.

  1. The MAREDAT global database of high performance liquid chromatography marine pigment measurements

    Science.gov (United States)

    Peloquin, J.; Swan, C.; Gruber, N.; Vogt, M.; Claustre, H.; Ras, J.; Uitz, J.; Barlow, R.; Behrenfeld, M.; Bidigare, R.; Dierssen, H.; Ditullio, G.; Fernandez, E.; Gallienne, C.; Gibb, S.; Goericke, R.; Harding, L.; Head, E.; Holligan, P.; Hooker, S.; Karl, D.; Landry, M.; Letelier, R.; Llewellyn, C. A.; Lomas, M.; Lucas, M.; Mannino, A.; Marty, J.-C.; Mitchell, B. G.; Muller-Karger, F.; Nelson, N.; O'Brien, C.; Prezelin, B.; Repeta, D.; Smith, W. O., Jr.; Smythe-Wright, D.; Stumpf, R.; Subramaniam, A.; Suzuki, K.; Trees, C.; Vernet, M.; Wasmund, N.; Wright, S.

    2013-03-01

    A global pigment database consisting of 35 634 pigment suites measured by high performance liquid chromatography was assembled in support of the MARine Ecosytem DATa (MAREDAT) initiative. These data originate from 136 field surveys within the global ocean, were solicited from investigators and databases, compiled, and then quality controlled. Nearly one quarter of the data originates from the Laboratoire d'Océanographie de Villefranche (LOV), with an additional 17% and 19% stemming from the US JGOFS and LTER programs, respectively. The MAREDAT pigment database provides high quality measurements of the major taxonomic pigments including chlorophylls a and b, 19'-butanoyloxyfucoxanthin, 19'-hexanoyloxyfucoxanthin, alloxanthin, divinyl chlorophyll a, fucoxanthin, lutein, peridinin, prasinoxanthin, violaxanthin and zeaxanthin, which may be used in varying combinations to estimate phytoplankton community composition. Quality control measures consisted of flagging samples that had a total chlorophyll a concentration of zero, had fewer than four reported accessory pigments, or exceeded two standard deviations of the log-linear regression of total chlorophyll a with total accessory pigment concentrations. We anticipate the MAREDAT pigment database to be of use in the marine ecology, remote sensing and ecological modeling communities, where it will support model validation and advance our global perspective on marine biodiversity. The original dataset together with quality control flags as well as the gridded MAREDAT pigment data may be downloaded from PANGAEA: http://doi.pangaea.de/10.1594/PANGAEA.793246.

  2. Determination of Capsaicin and Dihydrocapsaicin in Capsicum Fruit Samples using High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Ayman Abdel Ghafar

    2011-10-01

    Full Text Available The aim of the present study was to determine the content of capsaicin and dihydrocapsaicin in Capsicum samples collected from city markets in Riyadh (Saudi Arabia, calculate their pungency in Scoville heat units (SHU and evaluate the average daily intake of capsaicin for the population of Riyadh. The investigated samples consisted of hot chillies, red chillies, green chillies, green peppers, red peppers and yellow peppers. Extraction of capsaicinoids was done using ethanol as solvent, while high performance liquid chromatography (HPLC was used for separation, identification and quantitation of the components. The limit of detection (LOD of the method was 0.09 and 0.10 µg/g for capsaicin and dihydrocapsaicin, respectively, while the limit of quantification (LOQ was 0.30 and 0.36 µg/g for capsaicin and dihydrocapsaicin, respectively. Hot chillies showed the highest concentration of capsaicin (4249.0 ± 190.3 µg/g and the highest pungency level (67984.60 SHU, whereas green peppers had the lowest detected concentration (1.0 ± 0.9 µg/g; green peppers, red peppers and yellow peppers were non pungent. The mean consumption of peppers for Riyadh city population was determined to be 15.5 g/person/day while the daily capsaicin intake was 7.584 mg/person/day.

  3. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods

    Science.gov (United States)

    Liu, Wei; Wang, Dongmei; Liu, Jianjun; Li, Dengwu; Yin, Dongxue

    2016-01-01

    The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC) fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichuan were selected as the most valuable raw materials. Similarity analysis (SA) of HPLC fingerprints, hierarchical cluster analysis (HCA), principle component analysis (PCA), and discriminant analysis (DA) were further employed to provide accurate classification and quality estimates of P. fruticosa. Two principal components (PCs) were collected by PCA. PC1 separated samples from Kangding, Sichuan, capturing 57.64% of the variance, whereas PC2 contributed to further separation, capturing 18.97% of the variance. Two kinds of discriminant functions with a 100% discrimination ratio were constructed. The results strongly supported the conclusion that the eight samples from different regions were clustered into three major groups, corresponding with their morphological classification, for which HPLC analysis confirmed the considerable variation in phytochemical compositions and that P. fruticosa samples from Kangding, Sichuan were of high quality. The results of SA, HCA, PCA, and DA were in agreement and performed well for the quality assessment of P. fruticosa. Consequently, HPLC fingerprinting coupled with chemometric techniques provides a highly flexible and reliable method for the quality evaluation of traditional Chinese medicines. PMID:26890416

  4. AB063. Prevalence of thalassemias and hemoglobinopathies detected via high performance liquid chromatography in Filipinos

    Science.gov (United States)

    Silao, Catherine Lynn; Fabella, Terence Diane; Yuson, Ernesto; Naranjo, Maria Liza; Padilla, Carmencita

    2015-01-01

    Background The thalassemias and hemoglobinopathies are groups of autosomal recessive inherited blood disorders affecting the quantity and quality of hemoglobin. Patients with the disease can vary from clinically asymptomatic to transfusion dependent individuals. It is considered prevalent in many parts of the world particularly in Southeast Asia. Thus, screening and prevalence determination of these diseases are important in the Filipino population. The study aims to determine the prevalence of thalassemias and hemoglobinopathies in the Philippines using high performance liquid chromatography. Methods Referred patients by hematologists from different parts of the country from October 2008 to December 2014 were included. Peripheral blood extracted from the subjects, were hemolyzed and screened for thalassemias and hemoglobinopathies using VariantTM HPLC. Data interpretations were based on levels of the HbA2 Fetal Hb and HbA detected. Results Majority of the patients were beta thalassemics followed by alpha-thalassemics. Hemoglobin E was found in 1% of the population tested while 2% of the patients have beta thalassemia with HbE interaction. Conclusions A significant proportion of thalassemias and hemoglobinopathies were determined from the 6-year screening of Filipinos using VariantTM HPLC. The results of this study provide not only confirmation of the occurrence and prevalence of these growing and diverse groups of genetic blood diseases but also suggest that the use of HPLC is a useful screening tool.

  5. Quantitative Determination of Compounds from Akebia quinata by High-Performance Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Yen, Nguyen; Thu, Nguyen; Zhao, Bing Tian; Woo, Mi Hee; Min, Byung Sun [Catholic Univ. of Daegu, Gyeongsan (Korea, Republic of); Lee, Jae Hyun [Dongguk Univ., Yongin (Korea, Republic of); Kim, Jeong Ah [Kyungpook National Univ., Daegu (Korea, Republic of); Son, Jong Keun [Yeungnam Univ., Gyeongsan (Korea, Republic of); Choi, Jae Sui [Pukyung National Univ., Busan (Korea, Republic of); Woo, Eun Rhan [Chosun Univ., Gwangju (Korea, Republic of)

    2014-07-15

    To provide the scientific corroboration of the traditional uses of Akebia quinata (Thunb.) Decne., a detailed analytical examination of A. quinata stems was carried out using a reversed-phase high performance liquid chromatography (RP-HPLC) method coupled to photodiode array detector (PDA) for the simultaneous determination of four phenolic substances; cuneataside D, 2-(3,4-dihydroxyphenyl)ethyl-O-β-D-glucopyranoside, 3-caffeoylquinic acid and calceolarioside B. Particular attention was focused on the main compound, 3-caffeoylquinic acid, which has a range of biological functions. In addition, 2-(3,4-dihydroxyphenyl)ethyl-O-β-D-glucopyranoside was considered as a discernible marker of A. quinata from its easy confuse plants. The contents of compounds 2 and 3 ranged from 0.72 to 2.68 mg/g and from 1.66 to 5.64 mg/g, respectively. The validation data indicated that this HPLC/PDA assay was used successfully to quantify the four phenolic compounds in A. quinata from different locations using relatively simple conditions and procedures. The pattern-recognition analysis data from 53 samples classified them into two groups, allowing discrimination between A. quinata and comparable herbs. The results suggest that the established HPLC/PDA method is suitable for quantitation and pattern-recognition analyses for a quality evaluation of this medicinal herb.

  6. Determination of sulphachloropyrazine-diaveridine residues by high performance liquid chromatography in broiler edible tissues

    Science.gov (United States)

    LI, Yongjun; BU, Shijin

    2015-01-01

    Diaveridine (DVD) is used in combination with sulphachloropyrazine (SPZ) as an effective antibacterial agent and antiprotozoal agent, respectively, in humans and animals. To gain a better understanding of the metabolism of SPZ and DVD in the food-producing animals, a high performance liquid chromatography (HPLC) method to determine and quantify sulphachloropyrazine (SPZ) and diaveridine (DVD) suspension residues from broilers is reported. Thirty healthy chickens were orally administered with sulphachloropyrazine-diaveridine (SPZ-DVD) suspension in water of 300 mg/l (SPZ) per day for seven successive days. Six chickens per day were slaughtered at 0, 1, 3, 5 and 7 days after the last administration. This procedure permitted SPZ and DVD to be separated from muscle tissue, liver, kidneys and skin with fat after extraction with acetonitrile and acetone under slightly acidic conditions. From the detected residuals in different tissues, we found that SPZ was quickly eliminated in liver and muscle, and slowly eliminated in kidney and skin with fat. DVD was quickly eliminated in liver and slowly eliminated in kidney. The withdrawal period of SPZ was 3.26, 3.72, 4.39 and 5.43 days in muscle, liver, kidney and skin with fat, respectively. The withdrawal period of DVD was 4.77, 4.94, 6.74 and 4.58 days in muscle, liver, kidney and skin with fat, respectively. Therefore, the suggested withdrawal period for SPZ-DVD suspension should be 7 days after dosing for seven successive days. PMID:26212255

  7. Analysis of Fluconazole in Human Urine Sample by High Performance Liquid Chromatography Method

    Science.gov (United States)

    Hermawan, D.; Ali, N. A. Md; Ibrahim, W. A. Wan; Sanagi, M. M.

    2013-04-01

    A method for determination of fluconazole, antifungal drug in human urine by using reversed-phased high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detector was developed. Optimization HPLC conditions were carried out by changing the flow rate and composition of mobile phase. The optimum separation conditions at a flow rate 0.85 mL/min with a composition of mobile phase containing methanol:water (70:30, v/v) with UV detection at a wavelength 254 nm was able to analyze fluconazole within 3 min. The excellent linearity was obtained in the range of concentration 1 to 10 μg/mL with r2 = 0.998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.39 μg/mL and 1.28 μg/mL, respectively. Solid phase extraction (SPE) method using octadecylsilane (C18) as a sorbent was used to clean-up and pre-concentrated of the urine sample prior to HPLC analysis. The average recoveries of fluconazole in spiked urine sample was 72.4% with RSD of 3.21% (n=3).

  8. Determination of multiple human arsenic metabolites employing high performance liquid chromatography inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Stice, Szabina; Liu, Guangliang; Matulis, Shannon; Boise, Lawrence H.; Cai, Yong

    2016-01-01

    During the metabolism of different arsenic-containing compounds in human, a variety of metabolites are produced with significantly varying toxicities. Currently available analytical methods can only detect a limited number of human metabolites in biological samples during one run due to their diverse characteristics. In addition, co-elution of species is often unnoticeable with most detection techniques leading to inaccurate metabolic profiles and assessment of toxicity. A high performance liquid chromatography inductively coupled mass spectrometry (HPLC-ICP-MS) method was developed that can identify thirteen common arsenic metabolites possibly present in human with special attention dedicated to thiolated or thiol conjugated arsenicals. The thirteen species included in this study are arsenite (AsIII), arsino-glutathione (As(GS)3), arsenate (AsV), monomethylarsonous acid (MMAIII), monomethylarsino-glutathione (MMAIII(GS)2), monomethylarsonic acid (MMAV), dimethylarsinous acid (DMAIII (from DMAIIII)), S-(dimethylarsinic)cysteine (DMAIII(Cys)), dimethylarsino-glutathione (DMAIII(GS)), dimethylarsinic acid (DMAV), dimethylmonothioarsinic acid (DMMTAV), dimethyldithioarsinic acid (DMDTAV), dimethylarsinothioyl glutathione (DMMTAV(GS)). The developed method was applied for the analysis of cancer cells that were incubated with Darinaparsin (DMAIII(GS)), a novel chemotherapeutic agent for refractory malignancies, and the arsenic metabolic profile obtained was compared to results using a previously developed method. This method provides a useful analytical tool which is much needed in unequivocally identifying the arsenicals formed during the metabolism of environmental arsenic exposure or therapeutic arsenic administration. PMID:26708625

  9. High-performance liquid chromatography method validation for determination of tetracycline residues in poultry meat

    Directory of Open Access Journals (Sweden)

    Vikas Gupta

    2014-01-01

    Full Text Available Background: In this study, a method for determination of tetracycline (TC residues in poultry with the help of high-performance liquid chromatography technique was validated. Materials and Methods: The principle step involved in ultrasonic-assisted extraction of TCs from poultry samples by 2 ml of 20% trichloroacetic acid and phosphate buffer (pH 4, which gave a clearer supernatant and high recovery, followed by centrifugation and purification by using 0.22 μm filter paper. Results: Validity study of the method revealed that all obtained calibration curves showed good linearity (r2 > 0.999 over the range of 40-4500 ng. Sensitivity was found to be 1.54 and 1.80 ng for oxytetracycline (OTC and TC. Accuracy was in the range of 87.94-96.20% and 72.40-79.84% for meat. Precision was lower than 10% in all cases indicating that the method can be used as a validated method. Limit of detection was found to be 4.8 and 5.10 ng for OTC and TC, respectively. The corresponding values of limit of quantitation were 11 and 12 ng. Conclusion: The method reliably identifies and quantifies the selected TC and OTC in the reconstituted poultry meat in the low and sub-nanogram range and can be applied in any laboratory.

  10. [Determination of five coumarins in toys by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Yang, Rongjing; Wei, Biwen; Gao, Huan; Yu, Wenjia

    2012-02-01

    A rapid analytical method for the determination of five coumarins (coumarin, 7-methoxycoumarin, dihydrocoumarin, 7-methyl coumarin and 7-ethoxy-4-methyl coumarin) in toys by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has been developed. After ultrasonic extraction in tetrahydrofuran, the samples were analyzed by HPLC-MS/MS in multi-reaction monitoring (MRM) mode. Acetonitrile and 0.1% acetic acid were used as the mobile phases with gradient elution. The linear ranges of calibration curves were 10 - 1 000 microg/L, and the limits of quantification (LOQ) (S/N > 10) were 2.0 microg/L for all the analytes, except that the LOQ for dihydrocoumarin was 5.0 microg/L. The recoveries of the five coumarins spiked in three types of samples were in the ranges of 93.2% - 105.8%, 97.3% - 103.2% and 96.8% - 102.9%, with the relative standard deviations in the ranges of 4.35% - 8.27%, 3.65% - 6.73% and 4.03% - 6.45%, respectively. The method was applied in the determination of 12 toy samples. The five analytes were found in 9 samples, and in some cases, the presence of quite high concentrations of these coumarins in the toys should be a matter of concern.

  11. Analysis of lipoprotein profiles of healthy cats by gel-permeation high-performance liquid chromatography.

    Science.gov (United States)

    Mizutani, Hisashi; Sako, Toshinori; Okuda, Hiroko; Arai, Nobuaki; Kuriyama, Koji; Mori, Akihiro; Yoshimura, Itaru; Koyama, Hidekazu

    2016-09-01

    Density gradient ultracentrifugation (DGUC) and gel electrophoresis are conventionally used to obtain lipoprotein profiles of animals. We recently applied high-performance liquid chromatography with a gel permeation column (GP-HPLC) and an on-line dual enzymatic system to dogs for lipoprotein profile analysis. We compared the GP-HPLC with DGUC as a method to obtain a feline lipoprotein profile. The lipoprotein profiles showed large and small peaks, which corresponded to high-density lipoprotein (HDL) and low-density lipoprotein (LDL), respectively, whereas very low-density lipoprotein (VLDL) and chylomicron (CM) were only marginally detected. This profile was very similar to that of dogs reported previously. Healthy cats also had a small amount of cholesterol-rich particles distinct from the normal LDL or HDL profile. There was no difference in lipoprotein profiles between the sexes, but males had a significantly larger LDL particle size (P=0.015). This study shows the feasibility of GP-HPLC for obtaining accurate lipoprotein profiles with small sample volumes and provides valuable reference data for healthy cats that should facilitate diagnoses.

  12. Determination of xanthohumol in beer based on cloud point extraction coupled with high performance liquid chromatography.

    Science.gov (United States)

    Chen, Ligang; Zhao, Qi; Jin, Haiyan; Zhang, Xiaopan; Xu, Yang; Yu, Aimin; Zhang, Hanqi; Ding, Lan

    2010-04-15

    A method based on coupling of cloud point extraction (CPE) with high performance liquid chromatography separation and ultraviolet detection was developed for determination of xanthohumol in beer. The nonionic surfactant Triton X-114 was chosen as the extraction medium. The parameters affecting the CPE were evaluated and optimized. The highest extraction yield of xanthohumol was obtained with 2.5% of Triton X-114 (v/v) at pH 5.0, 15% of sodium chloride (w/v), 70 degrees C of equilibrium temperature and 10 min of equilibrium time. Under these conditions, the limit of detection of xanthohumol is 0.003 mg L(-1). The intra- and inter-day precisions expressed as relative standard deviations are 4.6% and 6.3%, respectively. The proposed method was successfully applied for determination of xanthohumol in various beer samples. The contents of xanthohumol in these samples are in the range of 0.052-0.628 mg L(-1), and the recoveries ranging from 90.7% to 101.9% were obtained. The developed method was demonstrated to be efficient, green, rapid and inexpensive for extraction and determination of xanthohumol in beer.

  13. Quantification of mRNA by RT-competitive-PCR and high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The use of RT-competitive-PCR with high performance liquid chromatography (HPLC) detection to quantify the absolute number of mRNA copies in mammalian cells is reported. As an example, the glutathione transferase (GST)-α mRNA in human hepatoma Hep G2 cells has been estimated. A PCR-generated internal standard was used as a competitor, co-amplified with the GST-α target sequence. The RT-competitive-PCR method was improved by designing target and competitor molecules which differed in only 30 base pairs. This allowed the two sequences to be co-amplified with the same efficiency. This improvement also facilitated a wider ratio to be used than previous methods (target:competitor ratio between 0.2 and 5). Products were baseline separated by HPLC using an ion-exchange column readily quantified at 260 nm. To validate the improved methodology, the effect of a known GST-α inducer, the anticancer drug oltipraz, was shown to induce GST-α mRNA up to 3-fold in Hep G2 cells. The RT-competitive PCR-HPLC method provides a reliable and sensitive way to quantify the amount of specific mRNA with 0.1 ng of total RNA.

  14. DETERMINATION OF TELMISARTAN IN PHARMACEUTICAL FORMULATIONS BY REVERSE PHASE-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    Manoj S. Charde

    2012-05-01

    Full Text Available A simple, sensitive and reproducible reverse-phase high performance liquid chromatographic (RP-HPLC method has been developed for the quantitative estimation of Telmisartan (TELM in the pharmaceutical formulations. Chromatographic separation was achieved on a 250 × 4.6 mm, 5μ, Waters symmetry column. The flow rate was 1 ml/min and eluent was monitored by absorbance at 230 nm using a mixture of Methanol and Acetonitrile (pH 3.0±0.01 in the ratio of 30:70 (v/v. The retention time of Telmisartan was found to be 7.9 min. Calibration plots were linear in the concentration range of 10-50 μg/ml for Telmisartan with correlation coefficient (R2 0.999. The proposed method was validated by testing its linearity, recovery, specificity, system suitability, precision (Interday, intraday, analyst and instrument precision, robustness and LOD/LOQ values and it was successfully employed for the determination of Telmisartan in pharmaceutical tablet formulations.

  15. Determination of Acrylamide Metabolite ,Mercapturic Aicd by High Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    WUYi-Qun; YUAi-Ru; 等

    1993-01-01

    A HPLC Assay was developed to indentify and measure the metabolite of acrylamide,mercapturic acid,N-Acetyl-s-(propionamide)-cyteine(APC)in urine O-phthalaldehyde (OPA)was utilized as a precolumm derivatizing agent in the assay.This derivative was isolated with a good selectivity by high performance liquid chromatography(HPLC)employing reversed phase ODS columns.The quantiation of the mercapturic acid derivative was reproducible and with a detection limit of 1 pmol.The average coefficient of variation for the runs carried out on the same day was approximately 4.6% at the range of 80-160μmol·l-1 of APC,and the mean analytical recovery from urine samples was 94%.The metabolite of urine of workers exposed to acrylamide was identified as N-acetyl-s-(propionamide)-cysteine by HPLC chromatography and fluorescence scan and HPLC-Mass spectra.All results were identical with the authentic synthesized compound.

  16. [Determination of histamine in canned fish by high performance liquid chromatography with pre-column derivatization].

    Science.gov (United States)

    Jin, Gaowa; Cai, Youqiong; Yu, Huijuan; Qian, Beilei

    2010-11-01

    A pre-column derivatization-high performance liquid chromatographic (HPLC) method has been developed for the determination of histamine in canned fish. The homogenated samples were ultrasonically extracted with perchloric acid aqueous solution, derivatized with dansyl chloride and diluted with acetonitrile to a desired volume. The samples were determined by HPLC with ultraviolet detector and quantified by external standard method. Adopting a C18 column with 1.8 microm stationary phase particles, the analysis time for each sample was smaller than 5 min with the flow rate of 0.3 mL/min. It can decrease the consumption of the mobile phase and save the cost. The linear range was 0.08-8.00 mg/L for histamine. The correlation coefficient was 0.999 98. The average recoveries of histamine at different concentration levels in spiked samples were greater than 96% and the relative standard deviations (RSDs) were smaller than 2.5%. The quantitation limit was 5.00 mg/kg for histamine in canned fish by HPLC. The results indicated that this HPLC method is fast, sensitive, reproducible and practical for the routine analysis of histamine in canned fish.

  17. A stability-indicating high performance liquid chromatography method to determine apocynin in nanoparticles

    Directory of Open Access Journals (Sweden)

    Juliana Kovalczuk de Oliveira

    2017-04-01

    Full Text Available In this study, we developed and validated a fast, specific, sensitive, precise and stability-indicating high performance liquid chromatography (HPLC method to determine the drug apocynin in bovine serum albumin (BSA nanoparticles. Chromatographic analyses were performed on an RP C18 column and using a photodiode array detector at a wavelength of 276 nm. Mobile phase consisted of a mixture of acetonitrile and 1% acetic acid (60:40, v/v, and it was eluted isocratically at a flow rate of 0.8 mL/min. The retention time of apocynin chromatographic peak was 1.65 min. The method was linear, precise, accurate and specific in the range of 5–100 μg/mL. The intra- and inter-day precisions presented relative standard deviation (RSD values lower than 2%. The method was robust regarding changes in mobile phase proportion, but not for flow rate. Limits of detection and quantitation were 78 ng/mL and 238 ng/mL, respectively. Apocynin was exposed to acid and alkali hydrolysis, oxidation and visible light. The drug suffered mild degradation under acid and oxidation conditions and great degradation under alkali conditions. Light exposure did not degrade the drug. The method was successfully applied to determine the encapsulation efficiency of apocynin in BSA nanoparticles.

  18. Simultaneous Determination of Four Preservatives in Foodstuffs by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Mohammad Faraji

    2016-04-01

    Full Text Available Background and objectives:  High concentration of preservatives in food may result in gastrointestinal disturbances whereby some patients suffering from asthma, rhinitis, or urticaria. The aim of this study is the introduction and optimization a new method for simultaneous determination of four preservatives (SB, PS, MP, PP in foodstuff by high performance liquid chromatography. Materials and methods: Important factors in extraction, separation and determination process were optimized using the one variable at a time method.  Figures of merit of the proposed method were evaluated. The amount of SB, PS, MP, PP in some food samples were determined using the proposed method. Result: The results showed that the obtained chromatogram of extract was free of significant interferences. The preservatives recoveries ranged from 88% to 110 %. Concentration of SB, PS, MP and PP in the 20studied samples ranges between N.D-639.9, N.D -214.5, N.D -579.8 and N.D -30.5 mg kg-1, respectively  Conclusion: The performance and reliability of proposed method as a simple, efficient and fast method for determination of SB, PS, MP, PP in the food samples was demonstrated.

  19. High-performance liquid chromatographic separation of subcomponents of antimycin A.

    Science.gov (United States)

    Abidi, S L

    1988-08-05

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, A1a, A1b, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins A1, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpreted based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  20. High-performance liquid-chromatographic separation of subcomponents of antimycin-A

    Science.gov (United States)

    Abidi, S.L.

    1988-01-01

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  1. High-Performance Liquid Chromatographic Quantification of Flavonoids in Eriocaulaceae Species and Their Antimicrobial Activity

    Directory of Open Access Journals (Sweden)

    Lourdes Campaner dos Santos

    2009-11-01

    Full Text Available Quantification of prepared samples by analysis using high performance liquid chromatography with DAD detection was developed to analyze rutin, 6-methoxyapigenin, and 6-methoxyapigenin-7-O-β-D-glucopyranoside isolated from methanolic extracts of different genus: Syngonanthus, Leiothix and Eriocaulon (Eriocaulaceae. The linearity, accuracy, and the inter-day precision of the procedure were evaluated. The calibration curves were linear. The recoveries of the flavonoids in the samples analyzed were 96.3% to 98.5%. The percentage coefficient of variation for the quantitative analysis of the flavonoids in the analyses of the samples was under 5%. The antimicrobial activity of the five methanol extracts of these Eriocaulaceae species was assayed against the microorganisms Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Salmonella setubal, Saccharomyces cerevisiae and Candida albicans. Measured MIC values ranged from 1.25 to 10.00 mg/mL. The flavonoid contents suggest that Eriocaulaceae species may be a promising source of compounds to produce natural phytomedicines.

  2. Simultaneous determination of quinolones for veterinary use by high-performance liquid chromatography with electrochemical detection.

    Science.gov (United States)

    Rodríguez Cáceres, M I; Guiberteau Cabanillas, A; Galeano Díaz, T; Martínez Cañas, M A

    2010-02-01

    A selective method based on high-performance liquid chromatography with electrochemical detection (HPLC-ECD) has been developed to enable simultaneous determination of three fluoroquinolones (FQs), namely danofloxacin (DANO), difloxacin (DIFLO) and sarafloxacin (SARA). The fluoroquinolones are separated on a Novapack C-18 column and detected in a high sensitivity amperometric cell at a potential of +0.8 V. Solid-phase extraction was used for the extraction of the analytes in real samples. The range of concentration examined varied from 10 to 150 ng g(-1) for danofloxacin, from 25 to 100 ng g(-1) for sarafloxacin and from 50 to 315 ng g(-1) for difloxacin, respectively. The method presents detection limits under 10 ng g(-1) and recoveries around 90% for the three analytes have been obtained in the experiments with fortified samples. This HPLC-ECD approach can be useful in the routine analysis of antibacterial residues being less expensive and less complicated than other more powerful tools as hyphenated techniques.

  3. High-Performance Liquid Chromatographic Resolution of Neutral and Cationic Hetero[6]Helicenes.

    Science.gov (United States)

    Labrador, Geraldine M; Bosson, Johann; Breitbach, Zachary S; Lim, Yeeun; Francotte, Eric R; Sabia, Rocchina; Villani, Claudio; Armstrong, Daniel W; Lacour, Jérôme

    2016-04-01

    Cationic hetero[6]helicenes 1+, 2+ and 3+ have been recently disclosed. Herein we report on their enantiomeric separation using high-performance liquid chromatography. Separation of the antipodes can be achieved in preparative scale on neutral adducts with Chiralcel OD-I or Chiralpak ID CSP. Selectivity factors of 1.90, 1.67, and 1.96 were obtained for 1-H, 2-H, and 3-H, respectively. Separation can also be performed on the carbenium ions on regular Chiralpak IA CSP using water-containing eluents, thus allowing for enantiomeric purity determinations in aqueous environments. Resolution of neutral and cationic helicenes is also achieved on more recently developed LARIHC columns. The versatility of the cyclofructan phases allows for baseline separations for both cases and their loading capabilities are demonstrated. Finally, the configurational stability of 1+, 2+, and 3+ was measured. For each replacement of an oxygen atom by an amino group, the racemization barrier increases significantly (ΔG‡ = 29.8, 36.3 and >37 kcal mol(-1) for 1+, 2+, and 3+ respectively).

  4. Simultaneous determination of caffeine, theobromine, and theophylline by high-performance liquid chromatography.

    Science.gov (United States)

    Bispo, Marcia S; Veloso, Márcia Cristina C; Pinheiro, Heloísa Lúcia C; De Oliveira, Rodolfo F S; Reis, José Oscar N; De Andrade, Jailson B

    2002-01-01

    This work relates the development of an analytical methodology to simultaneously determine three methylxanthines (caffeine, theobromine, and theophylline) in beverages and urine samples based on reversed-phase high-performance liquid chromatography. Separation is made with a Bondesil C18 column using methanol-water-acetic acid or ethanol-water-acetic acid (20:75:5, v/v/v) as the mobile phase at 0.7 mL/min. Identification is made by absorbance detection at 273 nm. Under optimized conditions, the detection limit of the HPLC method is 0.1 pg/mL for all three methylxanthines. This method is applied to urine and to 25 different beverage samples, which included coffee, tea, chocolate, and coconut water. The concentration ranges determined in the beverages and urine are: theobromine; < 0.1 pg/mL to 47 microg/mL and < 0.1 pg/mL to 66.3 microg/mL for theophylline. The method proposed in this study is rapid and suitable for the simultaneous quantitation of methylxanthines in beverages and human urine samples and requires no extraction step or derivatization.

  5. Molecular monitoring of the intestinal flora by denaturing high performance liquid chromatography.

    Science.gov (United States)

    Goldenberg, Oliver; Herrmann, Stefanie; Marjoram, Gina; Noyer-Weidner, Mario; Hong, George; Bereswill, Stefan; Göbel, Ulf B

    2007-01-01

    Gut flora analysis is hampered by the complexity of the intestinal microbiota and by inherent limitations of culture-based approaches. Therefore, culture-independent molecular methods based upon 16S rRNA gene analysis were applied successfully for the analysis of complex microbial communities. However, generally accepted and validated profiling methods such as denaturing and temperature gradient gel electrophoresis (DGGE/TGGE) are still laborious and time consuming. Thus, we adapted the separation of amplified bacterial 16S rRNA gene fragments by denaturing high performance liquid chromatography (DHPLC) using the WAVE Microbial Analysis System as a rapid and convenient means to display complex intestinal bacterial communities and to monitor changes in the gut flora. The separation of 16S rRNA gene fragments amplified from reference strains representing main gut bacterial populations and from human stool samples revealed that DHPLC analysis effectively detects bacterial groups predominant in the human gut flora. The investigation of faecal samples from hospitalized patients before, during and after antibiotic therapy showed that PCR-based DHPLC can be used to monitor gut flora changes. Results from DHPLC analysis were comparable with DGGE profiles generated from the same samples, demonstrating that the adapted DHPLC protocol is well suited for the analysis of complex microbial communities.

  6. Determination of Duloxetine and Its Major Metabolites in Rabbit Plasma by High-Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    T. K. Laha

    2015-03-01

    Full Text Available A rapid and sensitive high performance liquid chromatographic method is described for simultaneous determination of duloxetine and its major metabolites, such as 4- hydroxy duloxetine (M7, Glucuronide conjugate of 5-hydroxy-6-methoxy duloxetine (M6 and Glucuronide conjugate of dihydrodiol duloxetine (M12 in rabbit plasma. HPLC analysis was carried out on a µ-Bondapak C18 column (250 mm × 4.6 mm, 5µm particle size using methanol: phosphate buffer (pH 7.9, 50 mM (7:3 v/v as the mobile phase at a flow rate of 1.5 ml/min. Detection was carried out at 224 nm with an UV detector. The above metabolites present in the rabbit plasma were characterized by retro-synthesis followed by NMR and MS study for structure confirmation and finally injected separately into the HPLC system. All the three retention time matches with the metabolites present in the plasma sample.

  7. Development and Validation of Reversed-Phase High Performance Liquid Chromatographic Method for Hydroxychloroquine Sulphate.

    Science.gov (United States)

    Singh, A; Roopkishora; Singh, C L; Gupta, R; Kumar, S; Kumar, M

    2015-01-01

    In the present work new, simple reversed-phase high performance liquid chromatographic method was developed and validated for the determination of hydroxychloroquine sulphate in blood plasma. Chloroquine sulphate was used as an internal standard. The chromatographic separation was achieved with octadecyl silane Hypersil C18 column (250×6 mm, 5 μm) using water and organic (acetonitrile:methanol: 50:50, v/v) mobile phase in 75:25 v/v ratio, with sodium 1-pentanesulfonate and phosphoric acid. This organic phase was maintained at pH 3.0 by orthophosphoric acid. The flow rate of 2.0 ml/min(.) with detection at 343 nm was used in the analysis. The calibration curve of standard hydroxychloroquine sulphate was linear in range 0.1-20.0 μg/ml. The method was validated with respected to linearity, range, precision, accuracy, specificity and robustness studies according to ICH guidelines. The method was found to be accurate and robust to analyze the hydroxychloroquine sulphate in plasma samples.

  8. Development and validation of a high-performance liquid chromatographic method for bioanalytical application with rimonabant.

    Science.gov (United States)

    Bhaumik, Uttam; Ghosh, Animesh; Chatterjee, Bappaditya; Sengupta, Pinaki; Darbar, Soumendra; Roy, Bikash; Nandi, Utpal; Pal, Tapan K

    2009-05-01

    A simple and feasible high-performance liquid chromatographic method with UV detection was developed and validated for the quantification of rimonabant in human plasma. The chromatographic separation was carried out in a Hypersil BDS, C(18) column (250 mm x 4.6mm; 5 microm). The mobile phase was a mixture of 10 mM phosphate buffer and acetonitrile (30:70, v/v) at a flow rate of 1.0 ml/min. The UV detection was set at 220 nm. The extraction recovery of rimonabant in plasma at three quality control (QC) samples was ranged from 84.17% to 92.64%. The calibration curve was linear for the concentration range of 20-400 ng/ml with the correlation coefficient (r(2)) above 0.9921. The method was specific and sensitive with the limit of quantification of 20 ng/ml. The accuracy and precision values obtained from six different sets of QC samples analyzed in separate occasions ranged from 88.13% to 106.48% and 0.13% to 3.61%, respectively. In stability tests, rimonabant in human plasma was stable during storage and assay procedure. The method is very simple, sensitive and economical and the assay was applied to human plasma samples in a clinical (pharmacokinetic) study of rimonabant.

  9. Determination of purine contents in different parts of pork and beef by high performance liquid chromatography.

    Science.gov (United States)

    Rong, Shengzhong; Zou, Lina; Zhang, Yannan; Zhang, Guangteng; Li, Xiaoxia; Li, Miaojing; Yang, Fenghua; Li, Chunmei; He, Yingjuan; Guan, Hongjun; Guo, Yupeng; Wang, Dong; Cui, Xinyu; Ye, Hongting; Liu, Fenghai; Pan, Hongzhi; Yang, Yuexin

    2015-03-01

    Determination of adenine, hypoxanthine, guanine and xanthine in different parts of pork and beef using high performance liquid chromatography was described. Chromatographic separation was carried out on Waters Atlantis T3 column (4.6 mm × 250 mm × 5 μm) with column temperature at 30 °C. The mobile phase contained 99% 10.0 mmol/L ammonium formate solution at pH 3.6 and 1.0% methanol. Chromatography was achieved at a flow rate of 1.0 mL/min and detection wavelength at 254 nm. The results indicated that total purine amounts in pork rump and beef sirloin were higher than those in other parts (Ppurine bases were hypoxanthine and adenine, and hypoxanthine content was the most highest in all samples (Ppurine and uricogenic purine base, we suggest that excess consumption of them be avoid, whereas pork loin chop and beef rib eye are more suitable for a low-purine diet. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. A novel high-performance liquid chromatography fingerprint approach to discriminate Phyllostachys pubescens from China

    Directory of Open Access Journals (Sweden)

    Jin Yong-Chun

    2012-01-01

    Full Text Available Background: A high-performance liquid chromatography fingerprint of different variants of Phyllostachys pubescens was developed for the source discrimination and quality control of Phyllostachys pubescens medicines produced in Zhejiang Province, China. Materials and Methods: Samples of Phyllostachys pubescens collected from nine cultivars in Zhejiang Province were used to establish the fingerprint. Taking the chromatographic peak (isoorientin as the reference peak, the chromatographic column was Sunfire C 18 ODS (250 mm×4.6 mm, 5 ΅m at a column temperature of 25°C. The mobile phase was acetonitrile 0.8% acetic acid water solution (in a gradient elution mode at a flow rate of 1 ml/min. The detection wavelength was 330 nm. Results: 20 common peaks were established in the chromatographic fingerprints of Phyllostachys pubescens. And then by comparing the UV and standard substance with those of the authentic standards and literature, eight main peaks in the fingerprints were identified. Data of nine cultivars were evaluated statistically using similarity analysis, hierarchical cluster analysis (HCA in order to establish a similarity standard of fingerprint for quality control of Phyllostachys pubescens, then to classify the samples. The similarity indexes were all above 0.95 between reference chromatogram and each sample′s chromatogram. Conclusion: in this study, the methods established are reliable, and could be used to evaluate the quality and to identify the species of Phyllostachys pubescens in the future.

  11. Chemical fingerprint analysis of Gentianae Radix et Rhizoma by high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Baozhong Duan

    2012-02-01

    Full Text Available Gentianae Radix et Rhizoma (also called “Longdan” in Chinese is commonly used for eliminating damp-heat and quenching the fire of liver and gall bladder in traditional Chinese medicine. In this study, a novel and reliable method using high-performance liquid chromatography (HPLC was developed both for quantitative analysis of four bioactive compounds (loganic acid, swertiamarin, gentiopicroside and sweroside and chemical fingerprint analysis of “Longdan”. In quantitative analysis, four compounds showed good regressions (R2>0.9987 within the test ranges and the recovery of the method was in the range 97.61−102.49%. In fingerprint analysis, ten characteristic peaks were selected to evaluate the similarities of the crude drugs, and the HPLC chromatograms of twenty samples from different regions of China showed similar patterns. The results demonstrated that the combination of the quantitative and chromatographic fingerprint analyses offered an efficient way to evaluate the quality consistency of Gentianae Radix et Rhizoma.

  12. Fingerprint chromatogram analysis of Pseudostellaria heterophylla (Miq.) Pax root by high performance liquid chromatography.

    Science.gov (United States)

    Han, Chao; Chen, Junhui; Chen, Bo; Lee, Frank Sen-Chun; Wang, Xiaoru

    2006-09-01

    A simple and reliable high performance liquid chromatographic (HPLC) method has been developed and validated for the fingerprinting of extracts from the root of Pseudostellaria heterophylla (Miq.) Pax. HPLC with gradient elution was performed on an authentic reference standard of powdered P. heterophylla (Miq.) Pax root and 11 plant samples of the root were collected from different geographic locations. The HPLC chromatograms have been standardized through the selection and identification of reference peaks and the normalization of retention times and peak intensities of all the common peaks. The standardized HPLC fingerprints show high stability and reproducibility, and thus can be used effectively for the screening analysis or quality assessment of the root or its derived products. Similarity index calculations based on cosine angle values or correlation methods have been performed on the HPLC fingerprints. As a group, the fingerprints of the P. heterophylla (Miq.) Pax samples studied are highly correlated with closely similar fingerprints. Within the group, the samples can be further divided into subgroups based on hierarchical clustering analysis (HCA). Sample grouping based on HCA coincides nicely with those based on the geographical origins of the samples. The HPLC fingerprinting techniques thus have high potential in authentication or source-tracing types of applications.

  13. Determination of capsaicin and dihydrocapsaicin in Capsicum fruit samples using high performance liquid chromatography.

    Science.gov (United States)

    Al Othman, Zeid Abdullah; Ahmed, Yacine Badjah Hadj; Habila, Mohamed Abdelaty; Ghafar, Ayman Abdel

    2011-10-24

    The aim of the present study was to determine the content of capsaicin and dihydrocapsaicin in Capsicum samples collected from city markets in Riyadh (Saudi Arabia), calculate their pungency in Scoville heat units (SHU) and evaluate the average daily intake of capsaicin for the population of Riyadh. The investigated samples consisted of hot chillies, red chillies, green chillies, green peppers, red peppers and yellow peppers. Extraction of capsaicinoids was done using ethanol as solvent, while high performance liquid chromatography (HPLC) was used for separation, identification and quantitation of the components. The limit of detection (LOD) of the method was 0.09 and 0.10 µg/g for capsaicin and dihydrocapsaicin, respectively, while the limit of quantification (LOQ) was 0.30 and 0.36 µg/g for capsaicin and dihydrocapsaicin, respectively. Hot chillies showed the highest concentration of capsaicin (4249.0 ± 190.3 µg/g) and the highest pungency level (67984.60 SHU), whereas green peppers had the lowest detected concentration (1.0 ± 0.9 µg/g); green peppers, red peppers and yellow peppers were non pungent. The mean consumption of peppers for Riyadh city population was determined to be 15.5 g/person/day while the daily capsaicin intake was 7.584 mg/person/day.

  14. REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD FOR THE ANALYSIS OF GLIPIZIDE IN PHARMACEUTICAL DOSAGE FORMS

    Directory of Open Access Journals (Sweden)

    Sheikh Rahila

    2010-12-01

    Full Text Available A rapid and sensitive reverse phase high performance liquid chromatographic methods depicted for the qualitative and quantitative assay of glipizide in pharmaceutical dosage forms. Glipizide was chromatographed on reverse phase C18 column with mobile phase consisting of 0.05 M Potassium Dihydrogen Orthophosphate: Methanol [15: 85 %v/v, pH 7.0 ± 0.05, adjusted with 1% Triethylamine]. The mobile phase was pumped at a flow rate 1 mL/min. Quantification was achieved by monitoring the ultraviolet absorbance at 225 ηm. The average retention time for Glipizide was found to be 3.21 ± 0.07. With this method, linearity was observed in the range of 10 – 2000 ηg/ml. The LOD and LOQ were found to be 5 ηg/ml and 15 ηg/ml respectively. The method was applicable for the analysis of drug in tablet formulation. The results of analysis were validated statistically.

  15. Analysis of metalaxyl racemate using high performance liquid chromatography coupled with four kinds of detectors.

    Science.gov (United States)

    Chen, Tao; Fan, Jun; Gao, Ruiqi; Wang, Tai; Yu, Ying; Zhang, Weiguang

    2016-10-07

    Chiral stationary phase-high performance liquid chromatography coupled with various detectors has been one of most commonly used methods for analysis and separation of chiral compounds over the past decades. Various detectors exhibit different characteristics in qualitative and quantitative studies under different chromatographic conditions. Herein, a comparative evaluation of HPLC coupled with ultraviolet, optical rotation, refractive index, and evaporative light scattering detectors has been conducted for qualitative and quantitative analyses of metalaxyl racemate. Effects of separation conditions on the peak area ratio between two enantiomers, including sample concentration, column temperature, mobile phase composition, as well as flow rate, have been investigated in detail. In addition, the limits of detection, the limits of quantitation, quantitative range and precision for these two enantiomers by using four detectors have been also studied. As indicated, the chromatographic separation conditions have been slight effects on ultraviolet and refractive index detections and the peak area ratio between two enantiomers remains almost unchanged, but the evaporative light scattering detection has been significantly affected by the above-mentioned chromatographic conditions and the corresponding peak area ratios varied greatly. Moreover, the limits of detection, the limits of quantitation, and the quantitative ranges of two enantiomers with UV detection were remarkably lower by 1-2 magnitudes than the others. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Quantitative determination of eleutheroside B and E from Acanthopanax species by high performance liquid chromatography.

    Science.gov (United States)

    Kang, J S; Linh, P T; Cai, X F; Kim, H S; Lee, J J; Kim, Y H

    2001-10-01

    Reversed-phase high performance liquid chromatographic method was applied for the determination of eleutheroside B and E in the various Acanthopanax species collected in Korea. The stationary phase used was Zorbax 300 SB C18 and a mobile phase program was used, which started at 6% acetonitrile for 2 min, and then a linear gradient was operated for the next 18 min to 17% acetonitrile at a flow rate of 1.0 ml/min. The column effluent was monitored at UV 210 nm. Identification was carried out by comparing the retention time and the LC/MS spectrum of each peak corresponding to eleutheroside B and E from sample with those of standards. In general, the contents of eleutheroside B and E in stems were higher than those in roots. Acanthopanax species could be classified into two groups based upon the contents of eleutheroside B and E: one group contains no or very little eleutheroside B and another contains both eleutheroside B and E.

  17. The determination of bromazepam in plasma by reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Le Solleu, H; Demotes-Mainard, F; Vinçon, G; Bannwarth, B

    1993-08-01

    A reversed-phase high-performance liquid chromatographic method has been developed for the determination of bromazepam, an anxiolytic benzodiazepine, in plasma. After a single-step extraction from alkalinized plasma with diethyl-ether in the presence of an internal standard (alpha-hydroxy-triazolam), the residues were chromatographed on a reversed-phase Nova Pak 5 microns C18 column, with a mobile phase of acetonitrile-water-triethylamine (700:300:4, v/v/v) adjusted to pH 7.4 with orthophosphoric acid. The limit of detection was 50 ng ml-1, using a 20 microliters injection with UV detection at 240 nm. Between-day and within-day relative standard deviations were lower than 6%. Studies of drug stability during sample storage at -20 degrees C and at +4 degrees C showed no degradation of bromazepam. However, bromazepam seemed to be degraded at ambient temperature, without any influence of light. This method is applied to the determination of bromazepam plasma levels in analytical toxicology.

  18. Development of high-performance liquid chromatographic for quality and authenticity control of Chinese propolis.

    Science.gov (United States)

    Cui-ping, Zhang; Shuai, Huang; Wen-ting, Wei; Shun, Ping; Xiao-ge, Shen; Ya-jing, Li; Fu-liang, Hu

    2014-07-01

    A RP-high-performance liquid chromatography (HPLC) method was developed for quality control of Chinese propolis by simultaneous analysis of 12 flavonoids and 8 phenolic acids. The results showed that vanillic acid, rutin, myricetin, and luteolin were not detected in all of the analyzed propolis and poplar tree gum samples. The caffeic acid, ferulic acid and p-coumaric acid were not detected in poplar tree gum but were detected in propolis, which suggest that they are practical indexes of distinguishing propolis from poplar tree gum. The flavonoid profiles of poplar tree gum were found to be similar to those of propolis, which are dominated by pinobanksin, pinocembrin, 3-O-acetylpinobanksin, chrysin, and galangin. Therefore, the proposed method could be applied to exclude poplar tree gum from propolis with cafferic acid, ferulic acid, and p-coumaric acid as qualitative markers, and distinguish poplar source resin from other illegal substances, and evaluate the quality grading of poplar-type propolis with pinobanksin, pinocembrin, 3-O-acetylpinobanksin, chrysin, and galangin as qualitative and quantitative markers. © 2014 Institute of Food Technologists®

  19. Enantioselective high-performance liquid chromatographic determination of nicardipine in human plasma.

    Science.gov (United States)

    Uno, T; Ohkubo, T; Sugawara, K

    1997-09-26

    A sensitive method for the enantioselective high-performance liquid chromatography (HPLC) determination of nicardipine in human plasma is described. (+)-Nicardipine, (-)-nicardipine and (+)-barnidipine as an internal standard are detected by an ultraviolet detector at 254 nm. Racemic nicardipine in human plasma was extracted by a rapid and simple procedure based on C18 bonded-phase extraction. The extraction samples were purified and concentrated on a pre-column using a C1 stationary phase and the enantiomers of nicardipine are quantitatively separated by HPLC on a Sumichiral OA-4500 column, containing a chemically modified Pirkle-type stationary phase. Determination of (+)- and (-)-nicardipine was possible in a concentration range of 5-100 ng ml(-1) and the limit of detection in plasma was 2.5 ng ml(-1). The recoveries of (+)- and (-)-nicardipine added to plasma were 91.4-98.4% and 93.3-96.7%, respectively, with coefficients of variation of less than 9.0 and 9.4% respectively. The method was applied to low level monitoring of (+)- and (-)-nicardipine in plasma from healthy volunteers.

  20. Quantitation of aflatoxins in walnut kernels by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Kabak, Bulent

    2014-01-01

    A total of 85 walnut samples collected between October 2012 and April 2013 in different provinces of Turkey were analysed for the presence of aflatoxins (AFs). The method involved methanol-water extraction, clean-up with immunoaffinity columns and a sensitive high-performance liquid chromatography coupled with fluorescence detection after post-column derivatisation. The method was validated for selectivity, linearity, trueness, precision, limit of detection and limit of quantification (LOQ), which met the performance criteria as set by EC regulation No. 401/2006. LOQs were 0.07, 0.04, 0.09 and 0.05 µg kg(-1) for AFB1, AFB2, AFG1 and AFG2, respectively. AFs were present in 9.4% of walnut samples (8/85) at total AFs levels ranging from 0.09 to 15.4 µg kg(-1). Only one of eight walnut samples exceeded the European Union limit of 2 and 4 µg kg(-1) for AFB1 and total AFs, respectively.

  1. Rapid analysis of estrogen receptor heterogeneity by chromatofocusing with high-performance liquid chromatography.

    Science.gov (United States)

    Hutchens, T W; Wiehle, R D; Shahabi, N A; Wittliff, J L

    1983-08-26

    Chromatofocusing principles have been utilized to develop a high-performance liquid chromatographic technique for the rapid and routine analysis of steroid receptor heterogeneity. Two anion-exchange columns (SynChropak AX-300 and AX-500) were compared for analytical and preparative chromatofocusing of estrogen receptor components. As many as ten different [125I]iodoestradiol-labeled binding proteins were identified in cytosols prepared from mammary gland and uterus. Estrogen receptors were well separated from other cytosolic proteins and recovery of activity routinely exceeded 90%. Parallel analyses of these cytosols to determine receptor size and shape indicated that HPLC chromatofocusing can be used effectively to study receptor isoforms with Stokes radii ranging from 30 A to greater than 70 A. In contrast to isoelectric focusing, this technique is compatible with the inclusion of a commonly used receptor-stabilizing agent, sodium molybdate. Inclusion of molybdate during chromatofocusing of molybdate-stabilized receptor allowed the identification of two acidic receptor species not previously reported.

  2. Determination of Benzalkonium Chloride in Nasal Drops by High-Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Danijela A. Kostić

    2012-01-01

    Full Text Available A high-performance liquid chromatography (HPLC system was used in the reversed phase mode for the determination of benzalkonium chloride (BKC in nosal drops. A Chromolit RP-18e, 100 x 4.6, (UM6077/035 column was used at 40 °C. The mobile phase, optimized through an experimental design, was a 70:30 (v/v mixture of 0.057M Na-heksansulphonate potassium, dihydrogen orthophosphate buffer (pH 2.9 and acetonitrile, pumped at a flow rate of 1.75 mL/min at maintaining column temperature at 40 °C. Maximum UV detection was achieved at 215 nm. The method was validated in terms of selectivity, linearity, repeatability, precision and accuracy. The method was successfully applied for the determination of BKC in a pharmaceutical formulation of nasal drop solution without any interference from common excipients and drug substance. All the validation parameters were within the acceptance range, concordant to ICH guidelines.

  3. Determination of benzalkonium chloride in viscous ophthalmic drops of azithromycin by high-performance liquid chromatography *

    Science.gov (United States)

    Shen, Yan; Xu, Sheng-jie; Wang, Shi-chun; Tu, Jia-sheng

    2009-01-01

    A high-performance liquid chromatography (HPLC) system was used in the reversed phase mode for the determination of benzalkonium chloride (BKC) in azithromycin viscous ophthalmic drops. A Venusil-XBP(L)-C18 (150 mm×4.6 mm, 5 μm) column was used at 50 °C. The mobile phase consisted of a mixture of methanol-potassium phosphate (16:5, v/v). Two sample preparation methods were compared. The results suggested that, compared with an extraction procedure, a deproteinization procedure was much quicker and more convenient. Using the deproteinization procedure for sample preparation, calibration curves were linear in the range 5.0~50 μg/ml. The within-day and inter-day coefficients of variation were less than 10%. The average recoveries were determined as 96.70%, 98.52%, and 97.96% at concentrations of 10.0, 30.0, and 50.0 μg/ml, respectively. Variability in precision did not exceed 5%. In conclusion, this HPLC method using a simple sample treatment procedure appears suitable for monitoring BKC content in azithromycin viscous ophthalmic drops. PMID:19946951

  4. High-performance liquid chromatographic analysis and pharmacokinetics of terazosin in healthy volunteers.

    Science.gov (United States)

    Kang, B C; Yang, C Q; Rhee, J E; Suh, O K; Shin, W G

    2001-01-01

    A high-performance liquid chromatographic (HPLC) analysis of terazosin in 1 ml of human plasma was developed using prazosin as an internal standard. The plasma sample was extracted with dichloromethane and ethylether and a 100-microl aliquot was injected onto the reversed-phase column. The mobile phase, 0.02 M sodium phosphate buffer:acetonitrile:tetrahydrofuran = 720:220:60 (v/v/v), was run at a flow rate of 0.8 ml/min and the column effluent was monitored using a florescence detector set at 370 and 250 nm for the emission and excitation wave numbers, respectively. The retention times for terazosin and prazosin were approximately 6.4 and 9.8 min, respectively, and the coefficients of variation of terazosin were generally low, below 6.4%. The present HPLC method was successful for the pharmacokinetic study of terazosin in healthy volunteers. Following oral administration of terazosin, 2 mg, to 20 healthy male volunteers, the area under the plasma concentration-time curve from time zero to time infinity was 421 +/- 71.8 ng h/ml and terminal half-life was 9.83 +/- 1.29 h.

  5. Determination of Residual Monomers in Polycarboxylate Superplasticizer Using High Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    GUO Liping; WANG Shaofeng; ZHANG Anfu; LEI Jiaheng; DU Xiaodi

    2011-01-01

    A procedure was developed for the determination of residual monomers in polycarboxylate superplasticizer (PCs) by reversed-phase high performance liquid chromatography (RP-HPLC). Four kinds of residual monomers were well separated and determined on a SinoChrom ODS-BP (C18) column with mobile phases composed of acetonitrile and phosphate buffer solution. The monomers were detected by UV detector at 205 nm and quantitatively analyzed with an external standard method. For those residual monomers, the linear response ranged from 4.0× 10-6 mol·L-1 to 2.0× 10-3 mol·L-1. The determination limit of acrylic acid, sodium methylallyl sulfonate and 2-Acrylamido-2-methylpropane sulfonic acid was 0.02× 10-5 mol·L-1, while that of methoxy-polyethylene glycol monoacrylate was 0.1 × 10-5 mol· L-1. The relative standard deviation (RSD) of high concentration samples was less than 1%, while that of the low concentration samples was between 1%-4%. The standard (additional) recovery ratio was 97.4% -104.2%.

  6. [Simultaneous determination of 10 synthetic colorants in cosmetics by high performance liquid chromatography].

    Science.gov (United States)

    Liu, Haishan; Qian, Xiaoyan; Lü, Chunhu; Zhu, Xiaoyu; Chen, Xiaomei; Mo, Weimin

    2013-11-01

    A high performance liquid chromatographic method was developed for the simultaneous determination of 10 synthetic colorants in cosmetics. The cosmetics were extracted by the ultrasonic technique with tetrahydrofuran (THF), dimethyl sulfoxide (DMSO) and methanol sequentially. Then the extracts were centrifuged for purification and separated on an Eclipse XDB-C18 column (150 mm x 4.6 mm, 5 microm) with gradient elution by acetonitrile and 0.02 mol/L ammonium acetate (pH 4.60, adjusted with acetic acid). A diode array detector was used to determine the colorants with the wavelengths ranging from 417 nm to 640 nm. The linear relationships of the 10 colorants between the peak areas and the mass concentrations were obtained in the range of 0.5-20.0 mg/L (r > 0.999). The limits of quantitation ranged from 10 to 20 mg/kg. The average recoveries at three concentration levels ranged from 92.9% to 108.8% with the relative standard deviations in the range of 0.5% to 6.1% (n = 6). The method is simple, rapid and sensitive. It is suitable for the simultaneous determination of the 10 colorants in the oil cosmetics, cream cosmetics and powder cosmetics.

  7. Simultaneous characterization and quantification of 17 main compounds in Rabdosia rubescens by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Sen Guo

    2017-04-01

    Full Text Available Rabdosia rubescens is a healthy herbal tea and well-known Chinese medicinal herb. To evaluate the quality of R. rubescens from China, a high performance liquid chromatography method with dual-wavelength detection was developed and validated. The method was successfully applied for the simultaneous characterization and quantification of 17 main constituents from four different cultivation regions in China. Under optimal conditions, analysis was performed on a Luna C-18 column and gradient elution with a solvent system of acetonitrile and 0.5% (v/v acetic acid–water at a flow rate of 1.0 mL/min and wavelength of 220 nm and 280 nm. All standard calibration curves exhibited good linearity (r2 > 0.9992 within the test ranges. The precision was evaluated by intraday and interday tests, which revealed relative standard deviation values within the ranges of 0.57–2.35% and 0.52–3.40%, respectively. The recoveries were in the range of 96.37–101.66%. The relative standard deviation values for stability and repeatability were < 5%. The contents of some compounds were low and varied with different cultivars. The proposed method could serve as a prerequisite for quality control of R. rubescens materials and products.

  8. [Determination of six pesticides in milk using cloud point extraction-high performance liquid chromatography].

    Science.gov (United States)

    Wang, Jian; Cui, Yanmei; Liu, Wei; Yang, Mingmin; Chen, Jianbo

    2007-11-01

    The feasibility of employing cloud point extraction (CPE) as extraction and preconcentration method for the recovery of herbicides from milk samples followed by high performance liquid chromatography (HPLC) analysis is demonstrated. An aqueous surfactant solution containing 60 g/L Tween 20 or Triton X-100 was heated with an appropriate concentration of (NH4)2SO4 or NaCl for the extraction of herbicides. The extract was analyzed by HPLC subsequently. Six herbicides in milk were analyzed simultaneously. The results showed that the linear dynamic ranges of detection were 20 - 10 000 microg/L for tralkoxydim, metribuzin and bromoxynil, 30 - 10 000 microg/L for mefenacet, and 50 - 10 000 microg/L for bensulfuron-methyl and nicosulfuron. The correlation coefficients were 0.998 1 - 0.999 7. The average recoveries of the six herbicides ranged from 85.09% to 96.74%. The relative standard deviations for the six herbicides were in the range of 1.90% - 3.98%. The limits of detection for the six pesticides were lower than the maximum residue limits (MRL) of China. The results indicate that the method is easier, faster, sensitive and produces less pollutants.

  9. Analysis of ciprofloxacin by a simple high-performance liquid chromatography method.

    Science.gov (United States)

    Wu, Shihn-Sheng; Chein, Chih-Yuan; Wen, Yen-Hsia

    2008-07-01

    A simple and sensitive high-performance liquid chromatographic method is described for the quantitative analysis of ciprofloxacin in pharmaceuticals and human plasma. The method employs reversed-phase chromatography using an RP-C18 column with an isocratic mobile phase of acetonitrile-2% acetic acid aqueous solution (16:84, v/v), umbelliferone as an internal standard, and a flow rate of 1.0 mL/min. The UV detector is set at 280 nm. The limit of detection is 0.25 microM (S/N = 3, injection volume = 10 microL). The regression equations are linear (r > 0.9999) over a range between 0.51 approximately 130 microM for the pharmaceutical analysis of ciprofloxacin and 0.51 approximately 64.8 microM for the biological analysis of ciprofloxacin in human plasma. The intra- and inter-day relative standard deviation and relative error are less than 3.39% and 5.71%, respectively. All the recoveries are greater than 93.8%. This method is successfully applied in a pharmacokinetic study of a volunteer who receives a 500 mg ciprofloxacin tablet.

  10. Determination of folates in seaweeds by high-performance liquid chromatography.

    Science.gov (United States)

    Rodríguez-Bernaldo de Quirós, A; Castro de Ron, C; López-Hernández, J; Lage-Yusty, M A

    2004-04-02

    A reversed-phase high-performance liquid chromatography (HPLC) method, with a combination of fluorescence and ultraviolet detectors, to determine the folate forms present in commercial macroalgae products form northwest Spain as part of nutritional studies in dehydrated and canned seaweeds is reported. The method includes extraction of folates from seaweed by heat treatment, deconjugation of folate polyglutamates by incubation with hog kidney conjugase and purification by solid-phase extraction (SPE) with strong anion-exchange (SAX) cartridges. Separation was achieved with a Tracer Extrasil ODS 5 microm 25 cm x 0.4 cm column using acetonitrile and potassium phosphate buffer (pH 2.21 as mobile phase. Good results were obtained with respect to repeatability (relative standard deviation (R.S.D.) or = 90.80%). The amount of folate (as folic acid) in the six species ranged from 61.4 to 161.6 microg per 100 g dry mass. In all the seaweeds studied (Himanthalia elongata, Laminaria ochroleuca, Palmaria spp., Undaria pinnatifida and Porphyra spp. and Saccorhiza polychides) the single most abundant form is 5-CH3-H4-folate, except Porphyra and Himanthalia.

  11. Simultaneous determination of thiamine and riboflavin in edible marine seaweeds by high-performance liquid chromatography.

    Science.gov (United States)

    Sánchez-Machado, D I; López-Cervantes, J; López-Hernández, J; Paseiro-Losada, P

    2004-03-01

    This study presents a high-performance liquid chromatography (HPLC) method for simultaneous determination of thiamine and riboflavin and the results of its application to a number of edible seaweeds that are sampled in dried form (Himanthalia elongata, Laminaria ochroleuca, Undaria pinnatifida, Palmaria sp., and Porphyra sp.) or as canned food (H. elongata and Saccorhiza polyschides). Samples are prepared by acid and enzymatic hydrolysis. Optimized conditions for reversed-phase HPLC with fluorescence detection are as follow: column, Kromasil 100 C18; column temperature, 35 degrees C; mobile phase, a 72:28 (v/v) mixture of 0.005 M ammonium acetate (pH 6.7)-methanol; and flow rate, 1.35 mL/min. With these conditions, recovery is 95.52% for thiamine and 90.08% for riboflavin, and the method precision (relative standard deviation) is 2.66% for thiamine and 2.21% for riboflavin. On a dry weight basis, thiamine contents range from 0.14 microg/g in dried H. elongata to 2.02 microg/g in dried Porphyra and riboflavin contents from 0.31 microg/g in canned H. elongata to 6.15 microg/g in dried Porphyra.

  12. Simultaneous determination of eleven characteristic lignans in Schisandra chinensis by high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Junyang Hu

    2013-01-01

    Full Text Available Background: Schisandra chinensis, one of the well-known traditional Chinese herbal medicines, is derived from the dry ripe fruits of Schisandra chinensis (Turcz. Baill. according to the 9th China Pharmacopeia. Lignans are the main components isolated from extracts of S. chinensis and their content varies depending on where S. chinensis was collected. We have established a qualitative and quantitative method based on the bioactive lignans for control of the quality of S. chinensis from different sources. Materials and Methods: To develop a high-performance liquid chromatography method, an Elite ODS C18 column (250 mm Χ 4.6 mm, 5μm at a column temperature of 30°C and flow rate of 1.0ml/min using acetonitrile (A and water (B as the mobile phase with a linear gradient and the peaks were monitored at 217 nm. Results: All calibration curves showed good linearity (r ≥ 0.9995 within test ranges. This method showed good repeatability for the quantification of these eleven components in S. chinensis with intra- and inter-day relative standard deviations less than 0.43% and 1.21%, respectively. In the recovery test, results of accuracy ranged from 99.51% to 101.31% with RSD values less than 2.68%, Conclusion: The validated method can be successfully applied to quantify the eleven investigated components in 22 samples of S. chinensis from different sources.

  13. Preparation and Characterization of a New Quercetin-bonded Stationary Phase for High Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    李来生; 方奕珊; 陈红; 张杨

    2012-01-01

    A quercetin-bonded silica gel stationary phase (QUSP) containing natural flavonoid ligand was first prepared via γ-glycidoxypropyltrimethoxysilane (KH-560) as a coupling reagent for high-performance liquid chromatography. Its chemical structure was characterized by Fourier infrared spectroscopy, elemental analysis, thermal thermogravimetry and 13C cross polarization/magic angle spinning nuclear magnetic resonance (CP/MAS NMR). The chromatographic property of QUSP was systematically evaluated by using neutral, basic and acidic aromatic com- pounds as probes. In order to clarify its retention mechanism, a comparative study of QUSP with conventional oc- tadecylsilyl-bonded stationary phase (ODS) was also carried out under the same conditions. The results showed that the new quercetin-bonded phase exhibited an excellent reversed-phase chromatographic property with relatively weak hydrophobicity. However, it has an advantage over ODS in the fast separation of polar aromatic compounds because the quercetin ligand could provide various sites besides hydrophobicity, such as hydrogen bonding, dipole-dipole, n-n staking and charge transfer interactions. QUSP was performed in the baseline separations of ion- ized polar basic or acidic compounds, including pyridines, anilines, pyrimidines, purines and phenols with symmet- ric peak shape in common mobile phases without buffer salt within relatively short time. The natural ligands from herbs are readily available and contain a variety of active sites, which facilitate the exploration of industrial chromatographic separation materials for green products.

  14. High performance liquid chromatography determination of theobromine and caffeine in cocoa beans gamma irradiated

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Anderson D.B. [Faculdade de Engenharia de Varginha, MG (Brazil); Mansur Neto, Elias [Minas Gerais Univ., Belo Horizonte, MG (Brazil)

    1997-12-01

    Irradiation is a processing technology that has been shown to be a wholesome process by many scientific studies conducted worldwide during the past 40 years, which has been approved by 37 countries. Irradiated foods have been studied so extensively, that the effects on foods are better understood than any other preservation process, including food freezing and dehydration. Cocoa beans has been commercially irradiated in countries such as Ivory Coast and Argentina. The alkaloids theobromine and caffeine are responsible for the mildly stimulating properties and bitter taste of cocoa and chocolate products. Previously fermented dried and nonfumigated cocoa beans were irradiated at doses of 0, 5.0, 10.0 and 20.0 kGy using Co-60 gamma rays. The samples were analysed for determining theobromine and caffeine contents in the cocoa beans by TIMBIE et al. (1978) high performance liquid chromatography (HPLC) method. Boiling water extracts were cooled, centrifuged and injected into the chromatograph. Theobromine and caffeine were quantitated at 273 nm and showed the tendency of decreasing as the dose of radiation increases. Theobromine and caffeine ranged from 42.3 to 37.1 mg/g and from 7.60 to 6.13 mg/g. respectively from 0 to 20.0 kGy. These results were discussed in relation to the possible acceptance of radiosterization of cocoa beans commercially up to the dose of 20.0 kGy. (author). 10 refs., 1 tab.

  15. Determination of mitomycin C in human aqueous humor and serum by high-performance liquid chromatography.

    Science.gov (United States)

    Li, W Y; Seah, S K; Koda, R T

    1993-09-08

    Mitomycin C (MMC) is used in the treatment of disseminated adenocarcinoma of the stomach and pancreas and is used in ophthalmology as adjunctive therapy in trabeculectomy. Since only small volumes of aqueous humor are available for analysis, a sensitive method requiring limited sample preparation was developed. An internal standard, 4-aminoacetophenone, was added to aqueous humor specimens, and the solution was directly injected into the high-performance liquid chromatographic (HPLC) column. The use of a short 50-mm C18 reversed-phase column gave adequate resolution of peaks with improved sensitivity. The method was applicable for determination of MMC in serum, although solid-phase extraction for sample clean-up was required prior to injection into the HPLC column, and analytical columns of 150-250 mm were necessary for adequate resolution of peaks. The method has been validated and is linear from 6.25 to 50 ng/ml in aqueous humor and from 10 to 500 ng/ml in serum.

  16. QUANTITATIVE ANALYSIS OF RAW MATERIAL OF TETRACYCLINE AND ITS RELATED SUBSTANCES BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    NABILA PERVEEN

    2006-01-01

    Full Text Available An isocratic method for the analysis of tetracycline (TC by high performance liquid chromatography (HPLC using polystyrene-divinylbenzene copolymer packing material is described. The method allows the complete separation of TC, 4-epitetracycline, anhydrotetracycline (ATC, 4-epianhydrotetracycline (EATC. A fermentation impurity, 2-acetyl-2-decarboxamidetetracycline is also resolved from TC. The mobile phase combines tert.-butanol, water and phosphate buffer, tetrabutylammonium sulphate and sodium ethylenediaminetetraacetate at pH 9.0 for elution at a temperature of 60°C. Among the organic modifiers examined, only tetrahydrofuran and tert.-butanol gave good results. For practical reasons, tert.-butanol was retained as the final organic modifier. The preliminary experiments were carried out on polystyrene-divinylbenzene copolymer packing material (PRP-I and PLRP-S columns. The selectivity of the columns is comparable. PLRP-S column was chosen as it shows better separation of tetracycline – anhydrotetracycline. The method was used to analyse the commercial samples.

  17. Determination of organic mercury species in soils by high-performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Hempel, M; Hintelmann, H; Wilken, R D

    1992-03-01

    Reversed-phase high-performance liquid chromatography with ultraviolet detection was optimized for the simultaneous separation and quantification of nine organic mercury compounds: methyl-, ethyl-, phenyl-, methoxyethyl-, ethoxyethyl-, benzoic and tolylmercury, mersalylic acid and nitromersol. The nine compounds were successfully separated on octadecylsilane columns (200 x 3 mm i.d.) by gradient elution with a methanol-water mixture ranging from 30 to 50% v/v. The detection limits for the various compounds are in the range 7.0-95.1 micrograms dm-3. For the extraction of five organomercurials from spiked soils, eight different extraction solutions were tested to differentiate between the total content and the available/soluble fraction of the analytes. Ammonium acetate solutions (1 mol dm-3) and water proved to be suitable agents for the estimation of the available and soluble fractions of methyl-, ethyl-, benzoic, methoxyethyl- and ethoxyethylmercury. For the determination of the total content of methyl- and benzoic mercury in soils, solutions of potassium iodide (1 mol dm-3)-ascorbic acid (0.1 mol dm-3) and oxalic acid (1 mol dm-3) provided recoveries in the ranges 53-81%. None of the solutions tested is suitable for the extraction of ethyl-, methoxyethyl- and ethoxyethylmercury.

  18. [Determination of clavulanic acid residue in milk by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Yang, Gang; Huang, Xianhui; Guo, Chunna; Fang, Qiuhua; He, Limin

    2012-06-01

    An analytical method was developed for the determination of clavulanic acid (CLAV) in milk by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). A 2 g milk sample was deproteinized by ethanol. The supernatant was transferred into a pear-shaped bottle to be evaporated to about 0.5 mL, and the residue was dissolved with ammonium acetate solution. The sample was determined by HPLC-MS/MS after the purification. The chromatographic separation was achieved on a Luna 5u C8 column using 0.1% formic acid in water and acetonitrile as mobile phases with gradient elution. The identification of CLAV was carried out by MS/MS equipped with electrospray ionization in negative scanning and multiple reaction monitoring (MRM) modes. Matrix-matched calibration standard was used for the quantification. The calibration curve showed perfect linear in the range of 10 - 400 microg/kg with the correlation coefficient of 0.999. The limit of detection (LOD, S/N > or = 3) was 10 microg/kg in milk, and the limit of quantification (LOQ, S/N > or = 10) was 20 microg/kg. The mean recoveries varied from 80.00% to 91.25% at the four spiked levels of LOQ, 1/2MRL (the maximum residue limit), MRL, and 2MRL with the relative standard deviations of 5.60% -8.77%. In conclusion, the established method can be applied for the determination of CLAV residues in milk.

  19. Biogenic amines in table olives. Analysis by high-performance liquid chromatography.

    Science.gov (United States)

    Hornero-Méndez, D; Garrido-Fernández, A

    1994-09-01

    Biogenic amines in fermented vegetables have scarcely been studied. Available data show that in table olives and fermented cucumbers their presence is rare and any determinations made have been restricted mainly to histamine. However, some microorganisms, especially those related to spoilage, found in the fermentation brines of such products may have amino acid decarboxylase activity and give rise to biogenic amines by unusual processes. A method for the simultaneous determination of eight biogenic amines (tryptamine, beta-phenylethylamine, putrescine, cadaverine, histamine, tyramine, spermidine, and spermine) has been developed to study their occurrence in fermented vegetables in more detail. The method consists of extraction of the amines from olive paste with 5% m/v trichloracetic acid and successive transfers into water-saturated n-BuOH and 0.1 mol l-1 HCl. An aliquot of this mixture is dried and derivatized with dansyl chloride. The dansyl derivatives are then analysed by high-performance liquid chromatography. Special emphasis has been given to optimization of the n-BuOH and 0.1 mol l-1 HCl extractions and to the derivatization conditions. By applying this method to the analysis of spoilt olives, the presence of some biogenic amines has been demonstrated. Thus a new method for monitoring the presence of biogenic amines during the fermentation of olives and for detecting anomalous fermentations is envisaged.

  20. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods.

    Directory of Open Access Journals (Sweden)

    Wei Liu

    Full Text Available The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichuan were selected as the most valuable raw materials. Similarity analysis (SA of HPLC fingerprints, hierarchical cluster analysis (HCA, principle component analysis (PCA, and discriminant analysis (DA were further employed to provide accurate classification and quality estimates of P. fruticosa. Two principal components (PCs were collected by PCA. PC1 separated samples from Kangding, Sichuan, capturing 57.64% of the variance, whereas PC2 contributed to further separation, capturing 18.97% of the variance. Two kinds of discriminant functions with a 100% discrimination ratio were constructed. The results strongly supported the conclusion that the eight samples from different regions were clustered into three major groups, corresponding with their morphological classification, for which HPLC analysis confirmed the considerable variation in phytochemical compositions and that P. fruticosa samples from Kangding, Sichuan were of high quality. The results of SA, HCA, PCA, and DA were in agreement and performed well for the quality assessment of P. fruticosa. Consequently, HPLC fingerprinting coupled with chemometric techniques provides a highly flexible and reliable method for the quality evaluation of traditional Chinese medicines.

  1. Quantitation of meloxicam in the plasma of koalas (Phascolarctos cinereus) by improved high performance liquid chromatography.

    Science.gov (United States)

    Kimble, Benjamin; Li, Kong Ming; Govendir, Merran

    2013-01-01

    An improved method to determine meloxicam (MEL) concentrations in koala plasma using reversed phase high performance liquid chromatography equipped with a photo diode array detector was developed and validated. A plasma sample clean-up step was carried out with hydrophilic- lipophilic copolymer solid phase extraction cartridges. MEL was separated from an endogenous interference using an isocratic mobile phase [acetonitrile and 50 mM potassium phosphate buffer (pH 2.15), 45 : 55 (v : v)] on a Nova-Pak C18 4-µm (300 × 3.9 mm) column. Retention times for MEL and piroxicam were 8.03 and 5.56 min, respectively. Peak area ratios of MEL to the internal standard (IS) were used for regression analysis of the calibration curve, which was linear from 10 to 1,000 ng/mL (r(2) > 0.9998). Average absolute recovery rates were 91% and 96% for MEL and the IS, respectively. This method had sufficient sensitivity (lower quantitation limit of 10 ng/mL), precision, accuracy, and selectivity for routine analysis of MEL in koala plasma using 250-µL sample volumes. Our technique clearly resolved the MEL peak from the complex koala plasma matrix and accurately measured MEL concentrations in small plasma volumes.

  2. Identification and quantitation of asparagine and citrulline using high-performance liquid chromatography (HPLC).

    Science.gov (United States)

    Bai, Cheng; Reilly, Charles C; Wood, Bruce W

    2007-03-28

    High-performance liquid chromatography (HPLC) analysis was used for identification of two problematic ureides, asparagine and citrulline. We report here a technique that takes advantage of the predictable delay in retention time of the co-asparagine/citrulline peak to enable both qualitative and quantitative analysis of asparagine and citrulline using the Platinum EPS reverse-phase C18 column (Alltech Associates). Asparagine alone is eluted earlier than citrulline alone, but when both of them are present in biological samples they may co-elute. HPLC retention times for asparagine and citrulline were influenced by other ureides in the mixture. We found that at various asparagines and citrulline ratios [= 3:1, 1:1, and 1:3; corresponding to 75:25, 50:50, and 25:75 (microMol ml(-1)/microMol ml(-1))], the resulting peak exhibited different retention times. Adjustment of ureide ratios as internal standards enables peak identification and quantification. Both chemicals were quantified in xylem sap samples of pecan [Carya illinoinensis (Wangenh.) K. Koch] trees. Analysis revealed that tree nickel nutrition status affects relative concentrations of Urea Cycle intermediates, asparagine and citrulline, present in sap. Consequently, we concluded that the HPLC methods are presented to enable qualitative and quantitative analysis of these metabolically important ureides.

  3. Identification and Quantitation of Asparagine and Citrulline Using High-Performance Liquid Chromatography (HPLC

    Directory of Open Access Journals (Sweden)

    Cheng Bai

    2007-01-01

    Full Text Available High-performance liquid chromatography (HPLC analysis was used for identification of two problematic ureides, asparagine and citrulline. We report here a technique that takes advantage of the predictable delay in retention time of the co-asparagine/citrulline peak to enable both qualitative and quantitative analysis of asparagine and citrulline using the Platinum EPS reverse-phase C18 column (Alltech Associates. Asparagine alone is eluted earlier than citrulline alone, but when both of them are present in biological samples they may co-elute. HPLC retention times for asparagine and citrulline were influenced by other ureides in the mixture. We found that at various asparagines and citrulline ratios [= 3:1, 1:1, and 1:3; corresponding to 75:25, 50:50, and 25:75 (μMol ml–1/μMol ml–1], the resulting peak exhibited different retention times. Adjustment of ureide ratios as internal standards enables peak identification and quantification. Both chemicals were quantified in xylem sap samples of pecan [Carya illinoinensis (Wangenh. K. Koch] trees. Analysis revealed that tree nickel nutrition status affects relative concentrations of Urea Cycle intermediates, asparagine and citrulline, present in sap. Consequently, we concluded that the HPLC methods are presented to enable qualitative and quantitative analysis of these metabolically important ureides.

  4. Determination of Residual Acrylamide in Medical Polyacrylamide Hydrogel by High Performance Liquid Chromatography tandem Mass Spectroscopy

    Institute of Scientific and Technical Information of China (English)

    WEI-WEI LI; HUI LI; ZHI-FEI LIU; QUN QIAO

    2009-01-01

    Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample was extracted with water and then cleaned up with ExtrelutTM 20. The polyaerylamide hydrogel sample and 20 clinical cases were analyzed by HPLC-MS/MS and isotope dilution quantifying technique in selected reaction monitoring (SRM) mode. Results Acrylamide was separated from polyacrylamide hydrogel. The concentration of acrylamide in polyacrylamide hydrogel ranged from 3.9×109 to 3.1×108g/L in the 20 clinical cases. The peak area was favorable linear and the range was up to 3 000 μg/L. The recovery rate was 103.1% with a relative standard deviation (RSD) of 6.20%, when the mark level was 50 μg/L. Conclusion HPLC-MS is a rapid, accurate, and sensitive method for the determination of residual acrylamide in medical polyacrylamide hydrogel.

  5. Determination of clomazone residues in soybean and soil by high performance liquid chromatography with DAD detection.

    Science.gov (United States)

    Hu, Jiye; Cao, Di; Deng, Zhubo

    2011-04-01

    A simple analysis method to detect clomazone residues in soybean and soil was developed using solid phase extraction coupled with high performance liquid chromatography with diode-array detection. The pesticide residues present in soybean and soil matrices were extracted with methanol-water and extracts purified with Florisil cartridges. The analytes from soybean and soil matrix were eluted with petroleum ether-acetic ether (10 mL, 95:5, v/v) and petroleum ether-acetic ether (2 mL, 95:5, v/v), respectively. The overall recovery of fortified soybean and soil at the levels of 0.01, 0.1 and 0.5 mg/kg ranged from 89.75% to 106.6%, and the coefficients of variation (CV) ranged from 1.68% to 4.93% (n = 3). The limit of quantification (LOQ) is 0.01 mg/kg. This method has been applied to the analysis of clomazone in real samples of soybean and soil. The dissipation of residue over the time in soil coincided with C = 1.189e(-0.0926t ) and the half-lives (T(1/2)) was 7.48 days. The final residue in soybean was lower than 0.01 mg/kg at harvest time. Direct confirmation of the analyte in real samples was achieved by gas chromatography-mass spectrometry.

  6. Detection of honey adulteration with starch syrup by high performance liquid chromatography.

    Science.gov (United States)

    Wang, Shaoqing; Guo, Qilei; Wang, Linlin; Lin, Li; Shi, Hailiang; Cao, Hong; Cao, Baosen

    2015-04-01

    According to saccharide profile comparison between starch syrups and pure honeys analysed through high performance liquid chromatography (HPLC), a characteristic peak was found at 15.25 min retention time in HPLC chromatogram of syrup, but no peak was observed at the same retention time in chromatogram of pure honeys. This characteristic peak for syrup was identified as an overlapping peak of oligosaccharides with more than 5 degree of polymerisation (DP) based on HPLC chromatogram comparison between starch syrup and a series of standard mono-, di- and oligosaccharides of 3-7 DP. Additionally syrup content correlated linearly with the height of the characteristic peak of syrup under different slope in two ranges 2.5-7.5% and 10-100%, respectively. Therefore, the characteristic peak at 15.25 min retention time can serve as a syrup indicator in HPLC analysis of the adulterated honeys. This new HPLC method for honey adulteration detection was further applied in an authenticity inspection on more than 100 commercial honeys. In addition to the improved accuracy of honey adulteration detection, the proposed HPLC method was simple, low cost and easy practice for honey product quality control by government department considering the popularity of HPLC device and technology. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Simultaneous Determination of Potassium Sorbate and Sodium Benzoate in Doogh Using High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    S. Sohrabvandi

    2015-09-01

    Full Text Available In this research, high performance liquid chromatography (HPLC as a simple and rapid technique was used for the determination of potassium sorbate and sodium benzoate in different brands of Doogh (typical Iranian drink based on fermented milk. The chromatographic separation was achieved with a C18 column (250 mm×4 I.D, 5 µm and one buffered mobile phase, acetate buffer (0.2 mol/L, pH4.4: acetonitrile (63:37 at a flow rate of 1 mL/min. The effluent was monitored at 235nm, respectively. The main affecting factors, such as Carrez solution amount, pH and centrifuge speed were optimized. Limits of detection (LODs were 1.823 for sorbic acid and 1.985 for benzoic acid. Relative standard deviations (RSDs for quintuplicate analyses were 4.4 for sorbic acid and 4.087 for benzoic acid. The method also showed good linearity in a range from 4 to 1000 mg/L with correlation coefficients (R2 of 0.990 for sorbic acid and 0.995 for benzoic acid. Recoveries for the two analytes were 80 for sorbic acid and 65 for benzoic acid. Comparing to the other techniques, the proposed method was significantly less time-consuming and had more acceptable accuracy, precision and interruption elimination in samples. The developed method was successfully used for the routine monitoring of benzoate and sorbate in Doogh.

  8. High-performance liquid chromatography of unmodified rosin and its applications in contact dermatology.

    Science.gov (United States)

    Sadhra, S; Gray, C N; Foulds, I S

    1997-10-24

    Rosin is a well recognised skin sensitiser and is also amongst the most common causes of occupational asthma. Due to its complex chemical composition, it is difficult to isolate its many components and this has hindered progress in the identification of the specific respiratory and contact allergens it contains. This paper reports the application of high-performance liquid chromatography and other analytical techniques to the isolation and identification of contact allergens in complex mixtures such as rosin. HPLC methods were developed in order to isolate as many rosin components as possible and these were then patch tested on rosin sensitive individuals. The structure of the most dermatologically active component was then determined using mass spectrometry, nuclear magnetic resonance and infrared techniques. An HPLC method has also been developed which will enable the identification of rosin in commercial products, providing a valuable tool for determining the cause of rosin contact allergy. Furthermore, mass spectral data for the common abieitic-type resin acids are compiled which were used to confirm the identification of the HPLC resin acid peaks and have not been reported previously.

  9. Determination of meropenem levels in human serum by high-performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Roth, Thomas; Fiedler, Stella; Mihai, Sidonia; Parsch, Hans

    2017-05-01

    Meropenem is a β-lactam broad-spectrum antibiotic and belongs to the subgroup of carbapenems. It is primarily used in intensive care units for intravenous treatment of severe infections. To avoid bacterial resistance or toxic side effects, the determination of serum meropenem concentration is highly advisable. A simple and fast method for the quantitative determination of meropenem in human serum using high-performance liquid chromatography with ultraviolet detection (HPLC/UV) was developed and validated. Meropenem was determined by an isocratic HPLC using a tris(hydroxymethyl)aminomethane buffer (pH 8.5; 15% methanol) as a mobile phase and UV detection at 300 nm, with a flow rate of 1.0 mL/min and an analysis time of 10 min. Chromatographic separation was performed on a Kinetex C18 column (5 μm, 150 × 4.6 mm). In order to remove undesired serum components, solid-phase extraction was used for sample preparation. Since meropenem is not stable in solution, sample and stock solution were stored at -80°C. After preparation, samples were stable at room temperature for at least 6 h. The calibration curve was linear from 3.5 to 200 mg/L with a correlation coefficient r(2) of 0.999. The method is accurate with an intra- and inter-assay precision <18.5%. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Determination by high-performance liquid chromatography of phenylbutazone in samples of plasma from fighting bulls.

    Science.gov (United States)

    Marti, M I González; Sánchez, González C I; Jiménez, Hernández; Cachán, García; Castro, de Cabo M J; Cuadrado, A L Garzón

    2002-03-25

    The purpose of this study was to investigate the possible presence of phenylbutazone in plasma samples from fighting bulls killed in 2nd and 3rd category bullrings in the province of Salamanca (Spain) in 1998, 1999 and 2000. For quantitative and qualitative determination, a high-performance liquid chromatograph was used, equipped with a photodiode-array detector and setting wavelengths at 240, 254 and 284 nm. The mobile phase optimized for the simultaneous detection of dexamethasone, betamethasone, flunixin and phenylbutazone, was 0.01 M acetic acid pH 3 in methanol (35:65 v/v) at a flow rate of 1 ml/min. Plasma samples were deproteinized with 400 microl of acetonitrile and 20 microl of the supernatant were injected directly into the chromatographic system equipped with a Lichrospher 60 RP select B column and guard column. For the quantitative analysis, standard calibration curves were made in a concentration range between 0.25 and 30 microg/ml, using betamethasone as internal standard. The retention time of phenylbutazone was 8.7 +/- 0.2 min and recovery was 83%. The detection and quantification limits were 0.016 and 0.029, respectively for A=240 nm. The study results show that 17 of the 74 samples analyzed in 1998, 18 of those from 1999 and 10 of those from 2000 were positive for phenylbutazone.

  11. [Simultaneous determination of four common nonprotein nitrogen substances in urine by high performance liquid chromatography].

    Science.gov (United States)

    Ma, Yuhua; Huang, Dongqun; Zhang, Rui; Xu, Shiru; Feng, Shun

    2013-11-01

    A high performance liquid chromatographic (HPLC) method was proposed to simultaneously determine four common nonprotein nitrogen substances, including creatine (Cr), creatinine (Cn), uric acid (Ua) and pseudouridine (Pu) in urine. After proteins being removed by acetone precipitation method, freeze drying and redissolving, the urine samples were analyzed by HPLC. Chromatographic separation was performed on a Waters RP18 Column (150 mm x 4.60 mm, 3.5 microm) in gradient elution mode using 10.0 mmol/L KH2PO4 solution (pH 4.78) and acetonitrile as mobile phases at a flow rate of 0.8 mL/min. The samples were detected at 220 nm. Rapid separation was achieved within 7 min. Under the optimized conditions, good linearities of four common nonprotein nitrogen substances were obtained in the range of 0.1-250 mg/L. The detection limits were 9.31 (Cr), 26.19 (Cn), 4.70 (Ua), an 6.30 (Pu) microg/L and the recoveries were in the range of 81%-111% with the relative standar deviations of 0.23%-2.78% (n = 3). The results demonstrate that this method is simple, rapid and accurate with good reproducibility, and can provide early diagnosis and preliminary judgment for type 2 diabetes mellitus (T2DM) patients with renal damage.

  12. Spectrophotometric and high performance liquid chromatographic methods for sensitive determination of bisphenol A.

    Science.gov (United States)

    Zhuang, Yafeng; Zhou, Meng; Gu, Jia; Li, Xiangmei

    2014-03-25

    A new spectrophotometric method for the determination of trace amounts of bisphenol A based on a diazotization-coupling reaction was developed. In acidic solution, clenbuterol was first diazotized with sodium nitrite, then coupled with bisphenol A to from an azo-compound [I] in NH3-NH4Cl buffer, which shows a maximum absorption at 410 nm. The effects of the amount of sodium nitrite, diazo reaction time, the amount of clenbuterol, coupling reaction time and coupling reaction temperature have been examined. Under the optional conditions, the determination of the linear range of bisphenol A is 0.24-8.4 μg/mL, correlation coefficient is 0.9905 and detection limit of this method is 0.15 μg/mL. The spectrophotometric method is simple, rapid, high sensitivity with better accuracy. High performance liquid chromatography (HPLC) technique combined with this new spectrophotometric method has been also developed for the measurement of bisphenol A. The analysis was achieved on a C18 column using water and methanol as a mobile phase and the detection was done spectrophotometrically at 410 nm. These reported methods were applied to the determination of bisphenol A in hot water in contact with commercially available table-water bottle samples.

  13. Methacrylate-bonded covalent-organic framework monolithic columns for high performance liquid chromatography.

    Science.gov (United States)

    Liu, Li-Hua; Yang, Cheng-Xiong; Yan, Xiu-Ping

    2017-01-06

    Covalent-organic frameworks (COFs) are a newfangled class of intriguing microporous materials. Considering their unique properties, COFs should be promising as packing materials for high performance liquid chromatography (HPLC). However, the irregular shape and sub-micrometer size of COFs synthesized via the traditional methods render the main obstacles for the application of COFs in HPLC. Herein, we report the preparation of methacrylate-bonded COF monolithic columns for HPLC to overcome the above obstacles. The prepared COF bonded monolithic columns not only show good homogeneity and permeability, but also give high column efficiency, good resolution and precision for HPLC separation of small molecules including polycyclic aromatic hydrocarbons, phenols, anilines, nonsteroidal anti-inflammatory drugs and benzothiophenes. Compared with the bare polymer monolithic column, the COF bonded monolithic columns show enhanced hydrophobic, π-π and hydrogen bond interactions in reverse phase HPLC. The results reveal the great potential of COF bonded monoliths for HPLC and COFs in separation sciences. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. A simple high-performance liquid chromatographic practical approach for determination of flurbiprofen

    Directory of Open Access Journals (Sweden)

    Muhammad Akhlaq

    2011-01-01

    Full Text Available A simple, rapid, sensitive, and specific high-performance liquid chromatography (HPLC assay for flurbiprofen has been developed and validated practically. The chromatography was conducted using Gemini C18 column (5 μm; 4.6 mm × 250 mm, Phenomenex, California, USA. The mobile phase containing disodium hydrogen phosphate solution (30 mM pH 7.0 and acetonitrile (50:50; and the isocratic flow rate of 1.0 ml/min were used in the current study. Detection was made at 247 nm. The calibration curve was linear (r ≥ 0.9996 over the concentration range of 5-50 mm/ml. Mean percentage (% recovery ± % relative standard deviation (RSD ranged from 97.07 ± 0.008 to 103.66 ± 0.013. Within-day and between-day precision were also in acceptable range of 98.83 ± 0.004 to 104.56 ± 0.009. In order to confirm the practical applicability of the method developed, flurbiprofen controlled release matrix tablets were subjected to the dissolution studies and the release rate was analyzed. The reported HPLC for flurbiprofen provides several advantages of simplicity, high specificity, accuracy, and very short run-cycle time. It is suggested that the method should be used for the routine quality control analysis of flurbiprofen pure drug and its dosage forms.

  15. Optimised determination of clobazam in human plasma with extraction and high-performance liquid chromatography analysis.

    Science.gov (United States)

    Bolner, A; Tagliaro, F; Lomeo, A

    2001-01-05

    The analysis of clobazam by high-performance liquid chromatography and UV detection is described herein. After adding an internal standard, 600 microl of plasma were extracted under basic conditions onto disposable cartridges packed with celite. The organic extract was then evaporated to dryness and the residue reconstituted in 200 microl of mobile phase. A 20 microl aliquot was injected into chromatograph. The HPLC system was equipped with an Ultrasphere C8 analytical column coupled with an UV detector set at 235 nm. The mobile phase was an acetate buffer 20 mM, pH 5.5, containing acetonitrile and triethylamine 70:30:0.01 (v/v); the flow-rate was 1.8 ml/min. Using this method, clobazam can be detected with a sensitivity limit of 6 ng/ml and the RSD% intra- and inter-assay were lower than 5%. For its ruggedness and reliability, the proposed method is particularly suitable for therapeutic drug monitoring in epilepsy.

  16. Quantitation of clobazam in human plasma using high-performance liquid chromatography.

    Science.gov (United States)

    Knapp, J; Bokník, P; Gumbinger, H G; Linck, B; Lüss, H; Müller, F U; Schmitz, W; Vahlensieck, U; Neumann, J

    1999-05-01

    A rapid and simple reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of clobazam concentrations in human blood samples is developed and validated. Solid-phase column extraction is performed to clean up blood samples before running the analytical HPLC system. The chromatography is isocratic with a mobile phase consisting of acetonitrile (20%, v/v), methanol (23%, v/v), and 0.1 M potassium hydrogen phosphate buffer (pH 3.6; 57%, v/v) at a constant flow rate of 2 mL/min. Clobazam is detected at 226 nm. Chromatography is completed within less than 25 min. The recovery rate is greater than 95% and linear over a wide range of drug concentrations. The intra-assay coefficient of variation percentage varies between 4.3 and 12. This method is used for therapeutic drug monitoring in patients undergoing antiepileptic therapy with clobazam. Plasma levels of clobazam ranged from 21 to 663 ng/mL. Other antiepileptic compounds, such as clonazepam and phenobarbital, did not interfere with the detection of clobazam.

  17. Determination of hexamethylenetetramine in foods by high-performance liquid chromatography (HPLC).

    Science.gov (United States)

    Lim, HoSoo; Kim, JungIm; Ko, KyungYuk; Kim, Meehye

    2014-01-01

    A simple and rapid method was developed and validated for the determination of hexamethylenetetramine (HMT) in foods. Samples were homogenised and extracted with methanol, followed by centrifugation. The resulting solution was filtered and injected into the high-performance liquid chromatograph (HPLC). HMT was separated using a Zorbax SCX-300 column coupled to a photodiode array detector. The calibration curve was linear in the range of 1.0-100 μg ml(-1), with good correlation coefficients (r(2) = 0.9992). The recoveries of HMT from foods spiked at levels of 10, 50 and 100 mg kg(-1) ranged from 91.6% to 103.8%, with relative standard deviations (RSDs) between 0.9% and 5.3%. The limit of detection and the limit of quantification of HMT were 0.3 and 1.0 mg kg(-1) based on three food matrixes (provolone cheese, glass noodle and tofu snack), respectively. Uncertainty associated with accuracy contributed mostly to the expanded uncertainty. No detectable levels of HMT were found in any of the samples retailed in Korea. The method was successful in determining HMT in foods.

  18. Detection of synthetic corticosteroids in bovine urine by chemiluminescence high-performance liquid chromatography.

    Science.gov (United States)

    Vázquez, B I; Feás, X; Lolo, M; Fente, C A; Franco, C M; Cepeda, A

    2005-01-01

    The development of a black market of chemical cocktails for illegal growth promotion in food-producing animals includes substances that are potentially dangerous for human health, such as synthetic corticosteroids. The potential presence of these residues in food makes it necessary to develop rapid and sensitive analytical methodologies to detect such substances, preferably in live animals before they arrive at the market. A chemiluminescence (CL) detection method for the determination of four synthetic corticosteroids (prednisolone, betamethasone, dexamethasone and flumethasone) in bovine urine has been developed. The proposed system, which does not need any derivatization procedure, offers an easy method well suited for routine research. Urine samples were homogenized with methanol:water (50:50, v/v) and centrifuged. The upper layer was collected and Strata X cartridges were used for cleaning up. The purified residues were evaporated to dryness and then redissolved in the mobile phase. Analysis of the extracts was performed using high-performance liquid chromatography with chemiluminescence detection, employing luminol as the CL reagent. The recovery curves, obtained at four spiking levels (different for each corticosteroid), showed that recoveries of at least 70% could be obtained for urine. The chemiluminescence detection procedure afforded satisfactory results with respect to sensitivity and the LOD and LOQ, taken as the first point of the regression curve, ranged from 4 ppb to 65 ppb. The maximum mean RSD was below 13% and below 15% for intra- and inter-day assay, respectively, in all cases.

  19. Simultaneous determination of ethinyl estradiol and drospirenone in oral contraceptive by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Viviane Benevenuti Silva

    2013-09-01

    Full Text Available A simple, rapid, economical and reliable high performance liquid chromatographic method has been developed and successfully applied in simultaneous determination of ethinyl estradiol and drospirenone in coated tablets. The HPLC method was performed on a LiChroCART® 100RP column (125x4 mm i.d., 5 µm with acetonitrile:water 50:50 (v/v as mobile phase, pumped at a flow rate of 1.0 mL.min-1. The fluorescence detection for ethinyl estradiol was made at λex= 280 nm and λem= 310 nm and a UV detection for drospirenone was made at 200 nm. The elution time for ethinyl estradiol and drospirenone were 4.0 and 5.7 min, respectively. The method was validated in accordance to USP 34 guidelines. The proposed HPLC method presented advantages over reported methods and is suitable for quality control assays of ethinyl estradiol and drospirenone in coated tablets.

  20. High-performance liquid chromatographic assay of free norepinephrine, epinephrine, dopamine, vanillylmandelic acid and homovanillic acid.

    Science.gov (United States)

    Gerlo, E; Malfait, R

    1985-09-13

    A procedure is described for the concurrent assay of free norepinephrine, epinephrine, dopamine, vanillylmandelic acid and homovanillic acid in physiological fluids using high-performance liquid chromatography with electrochemical detection. The column packing is an octadecyl-bonded silica. A single mobile phase containing 1-octanesulphonate is used for the assay of catecholamines and for the assay of the acidic metabolites. An efficient sample preparation scheme is presented for the isolation of the catecholamines and their acidic metabolites from the same sample aliquot. Catecholamines are extracted by ion exchange on small columns and adsorption on alumina, using dihydroxybenzylamine as an internal standard. Vanillylmandelic acid and homovanillic acid are recovered from the combined loading and washing effluents of the ion-exchange column by a solvent extraction procedure. Recovery of catecholamines averages 67%. The limit of detection for individual catecholamines is ca. 30 pg. Recoveries of vanillylmandelic acid and homovanillic acid average 77% and 87%, respectively. The use of the same mobile phase for the concurrent assay of catecholamines and their acidic metabolites considerably increases the throughput of samples in the chromatographic system by eliminating the time-consuming column-equilibration periods.

  1. Simultaneous determination of 11 preservatives in cosmetics by high-performance liquid chromatography.

    Science.gov (United States)

    Aoyama, Airin; Doi, Takahiro; Tagami, Takaomi; Kajimura, Keiji

    2014-10-01

    Preservatives prevent the growth of microorganisms in foods, pharmaceuticals and cosmetics. There exist numerous restrictions regarding the maximum allowable levels of preservatives in cosmetics. We analyzed 11 regulated preservatives in commercial cosmetics and manufacturers need to analyze their products for quality control purposes. However, methods used in previous studies to date have been inadequate for use by public institutions and manufacturers. Therefore, an effective, scalable method for the analysis of preservatives in cosmetics is required. We developed a novel method for the simultaneous determination of 11 regulated preservatives in cosmetics by high-performance liquid chromatography (HPLC). We applied the samples to a C18 column in a simple mobile phase (5 mmol/L ammonium formate solution and acetonitrile) with gradient elution at a flow rate of 1.0 mL/min at a single wavelength (230 nm). The correlation coefficients of the calibration curves were >0.997. The percent recoveries were 92.8-111.9% and the relative standard deviations were preservatives was >1.9. Because of the simple conditions for isolation and complete separation, the HPLC method can be effectively applied to the analysis of preservatives in commercially retailed cosmetics.

  2. High-Performance Liquid Chromatographic Ultraviolet Determination of Memantine Hydrochloride after In Vitro Transdermal Diffusion Studies

    Directory of Open Access Journals (Sweden)

    Sergio del Rio-Sancho

    2013-01-01

    Full Text Available The purpose of the present work was to validate an accurate and precise high-performance liquid chromatography (HPLC method involving ultraviolet detection for the quantitative analysis of memantine hydrochloride. In order to analyze a molecule with no chromophoric groups that could be detected by a UV/visible detector, it was necessary to extract the drug and to perform a dansylation reaction that enabled the UV/visible detection of the derivatized molecule. Separation was carried out with a 150 mm Kromasil C18 column at room temperature. The detection response, at 218 nm, was found to be linear in the concentration range from 0.5 to 50 μg/mL. The method was validated for specificity, linearity, precision, accuracy, limit of detection, limit of quantification, and robustness. The limit of detection (LOD was 0.144 μg/mL, and the limit of quantification (LOQ was 0.437 μg/mL. The dansylated memantine complex was stable for at least five days in all the conditions evaluated. The potential use of this method has been demonstrated by the quantification of memantine hydrochloride contained in samples from the study of its in vitro transdermal permeation.

  3. [Simultaneous determination of vitamins A, D3 and E in infant formula and adult nutritions by online two-dimensional liquid chromatography].

    Science.gov (United States)

    Zhang, Yanhai; Qibule, Hasi; Jin, Yan; Wang, Jia; Ma, Wenli

    2015-03-01

    A rapid method for the simultaneous determination of vitamins A, D3 and E in infant formula and adult nutritions has been developed using online two-dimensional liquid chromatography (2D-LC). First of all, C8 and polar embedded C18 columns were chosen as the first and second dimensional column respectively according to hydrophobic-subtraction model, which constituted excellent orthogonal separation system. The detection wavelengths were set at 263 nm for vitamin D3, 296 nm for vitamin E and 325 nm for vitamin A. The purification of vitamin D3 and quantifications of vitamins A and E were completed simultaneously in the first dimensional separation using the left pump of Dual Gradient LC (DGLC) with methanol, acetonitrile and water as mobile phases. The heart-cutting time window of vitamin D3 was confirmed according to the retention time of vitamin D3 in the first dimensional separation. The elute from the first dimensional column (1-D column) which contained vitamin D3 was collected by a 500 µL sample loop and then taken into the second dimensional column (2-D column) by the right pump of DGLC with methanol, acetonitrile and water as mobile phases. The quantification of vitamin D3 was performed in the second dimensional separation with vitamin D2 as internal standard. At last, this method was applied for the analysis of the three vitamins in milk powder, cheese and yogurt. The injected sample solution with no further purification was pre-treated by hot-saponification using 1. 25 kg/L KOH solution and extracted by petroleum ether solvent. The recoveries of vitamin D3 spiked in all samples were 75.50%-85.00%. There was no statistically significant difference for the results between this method and standard method through t-test. The results indicate that vitamins A, D3 and E in infant formula and adult fortified dairy can be determined rapidly and accurately with this method.

  4. Improving Peak Capacity in Fast On-Line Comprehensive Two-Dimensional Liquid Chromatography with Post First Dimension Flow-Splitting

    Science.gov (United States)

    Filgueira, Marcelo R.; Huang, Yuan; Witt, Klaus; Castells, Cecilia; Carr, Peter W.

    2011-01-01

    The use of flow splitters between the two dimensions in on-line comprehensive two dimensional liquid chromatography (LC×LC) has not received very much attention in comparison to their use in GC×GC where they are quite common. In principle, splitting the flow after the first dimension column and performing on-line LC×LC on this constant fraction of the first dimension effluent should allow the two dimensions to be optimized almost independently. When there is no flow splitting any change in the first dimension flow rate has an immediate impact on the second dimension. With a flow splitter one could for example double the flow rate into the first dimension column and do a 1:1 flow split without changing the sample loop size or the sampler’s collection time. Of course, the sensitivity would be diminished but this can be partially compensated by use of a larger injection; this will likely only amount to a small price to pay for this increased resolving power and system flexibility. Among other benefits, we found a 2-fold increase in the corrected 2D peak capacity and the number of observed peaks for a 15 min analysis time by using a post first dimension flow splitter. At a fixed analysis time this improvement results primarily from an increase in the gradient time resulting from the reduced system re-equilibration time and to a smaller extent it is due to the increased peak capacity achieved by full optimization of the first dimension. PMID:22017622

  5. Proteomic analysis of tears following acupuncture treatment for menopausal dry eye disease by two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry

    Science.gov (United States)

    Liu, Qingyu; Liu, Junling; Ren, Chengda; Cai, Wenting; Wei, Qingquan; Song, Yi; Yu, Jing

    2017-01-01

    Background The purpose of this study was to investigate whether acupuncture is effective at treating dry eye disease among postmenopausal women and to identify the possible mechanisms. Methods Twenty-eight postmenopausal women with dry eye disease were randomly divided into two groups: an acupuncture plus artificial tears (AC + AT) group and an artificial tears (AT) only group. After baseline examination of clinical parameters and tear sample collection, each patient received the designated modality of topical therapy for 2 months. Post-treatment documentation of clinical parameters was recorded, and tear samples were collected. Tear samples from the AC + AT group were subjected to two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry (2D nano-LC-MS/MS). Western blot analysis was also performed on tear samples from both groups. Results After treatment, the Ocular Surface Disease Index scores, symptom assessment scores, scores of sign assessment, and tear break-up time were significantly improved in both groups (P=0.000). Symptom assessment scores were significantly improved in the AC + AT group (P=0.000) compared with the AT group. 2D nano-LC-MS/MS identified 2,411 proteins, among which 142 were downregulated and 169 were upregulated. After combined AC + AT treatment, the abundance of secreted proteins was increased, whereas that of cytoplasmic proteins decreased (Pearson’s χ2 test, P=0.000, P=0.000, respectively). Proteins involved in immunity and regulation were also more abundant (Pearson’s χ2 test, P=0.040, P=0.016, respectively), while components and proliferation-related proteins were downregulated (Pearson’s χ2 test, P=0.003, P=0.011, respectively). Conclusion AC + AT treatment increased protein synthesis and secretion, and improved clinical symptoms. These results indicate that acupuncture may be a complimentary therapy for treating postmenopausal dry eye disease. PMID:28280333

  6. Ultra high pressure in the second dimension of a comprehensive two-dimensional liquid chromatographic system for carotenoid separation in red chili peppers.

    Science.gov (United States)

    Cacciola, Francesco; Donato, Paola; Giuffrida, Daniele; Torre, Germana; Dugo, Paola; Mondello, Luigi

    2012-09-14

    A comprehensive normal-phase × reversed-phase (NP-LC × RP-LC) liquid chromatography system was developed, and applied for analysis of the intact carotenoid composition of red chili peppers, with photodiode array and mass spectrometry detection. A micro-bore cyano column (250 mm × 1.0 mm, 5 μm d.p.) was chosen for the first dimension ((1)D) separation, interfaced to a second dimension ((2)D) C18 column (30 mm × 4.6 mm, 2.7 μm d.p.) packed with fused-core particles. Subsequently, two columns of the same stationary phase were coupled serially for second dimension separation, and operated under ultra high pressure LC conditions (UHPLC), within a cycle time of 1.50 or 1.00 min, and equal modulation times. Performances of the three different set-ups were evaluated, in terms of peak capacity values (n(c)), and afterwards corrected by taking into account both the under-sampling, and the orthogonality effects. After these adjustments, the peak capacity values were estimated as follows: n(c) 526, for the NP-LC × RP-LC system, n(c) 373, for the NP-LC × RP-UHPLC system with a 1.50 min modulation time, n(c) 639, for the NP-LC × RP-UHPLC system, with a 1.00 min modulation time. A total of 33 compounds were separated into 10 different chemical classes in the two-dimensional space, and identified by accurate IT-TOF (ion trap-time of flight) MS detection. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Preparation and characterization of high performance Schiff-base liquid crystal diepoxide polymer

    Energy Technology Data Exchange (ETDEWEB)

    Liu Huan; Fu Zien [Key Laboratory of Organic Polymer Material for Electronics, Guangzhou Institute of Chemistry, Chinese Academy of Sciences, P.O. BOX 1122, Guangzhou 510650 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Xu Kai, E-mail: xk@gic.ac.cn [Key Laboratory of Organic Polymer Material for Electronics, Guangzhou Institute of Chemistry, Chinese Academy of Sciences, P.O. BOX 1122, Guangzhou 510650 (China); Cai Hualun; Liu Xin [Key Laboratory of Organic Polymer Material for Electronics, Guangzhou Institute of Chemistry, Chinese Academy of Sciences, P.O. BOX 1122, Guangzhou 510650 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Chen Mingcai [Key Laboratory of Organic Polymer Material for Electronics, Guangzhou Institute of Chemistry, Chinese Academy of Sciences, P.O. BOX 1122, Guangzhou 510650 (China)

    2012-02-15

    Graphical abstract: The specific effects of highly conjugated Schiff-base moiety on thermal properties of the Schiff-base epoxy polymer were proposed first by us. From the point of view of structure-properties relationship, it can be considered that owing to the presence of the Schiff-base group, the high performance liquid crystal diepoxide polymer displayed improved thermal stability. Highlights: Black-Right-Pointing-Pointer In this work, we first proposed that specific effects of highly conjugated Schiff-base moiety on thermal properties of the Schiff-base epoxy polymer. Black-Right-Pointing-Pointer As one aim of this study, the thermal and thermal-oxidative stabilities of the thermosets were studied by TGA under nitrogen and under air. Black-Right-Pointing-Pointer The second aim of this study was to further understand the thermal degradation mechanism. Black-Right-Pointing-Pointer For thermal degradation mechanism of this polymer under nitrogen, TG-IR was used to investigate volatile components, and SEM/EDS was used to explore morphologies and chemical components of the residual char. Black-Right-Pointing-Pointer From the point of view of structure-properties relationship, it can be considered that owing to the presence of the Schiff-base group, the high performance liquid crystal diepoxide polymer displayed the improved thermal stability. - Abstract: A novel Schiff-base liquid crystal diepoxide polymer was prepared via a thermal copolymerization of a Schiff-base epoxy monomer (PBMBA) with a diamine co-monomer (MDA). We first proposed that specific effects of highly conjugated Schiff-base moiety on thermal properties of the Schiff-base epoxy polymer (PBMBA/MDA). Thermal degradation behavior of the polymer was characterized using thermogravimetric analysis (TGA) under nitrogen and under air, respectively. Thermogravimetric data obtained from TGA under nitrogen and under air reveal that PBMBA/MDA exhibits higher thermal stability compared with bisphenol-A type

  8. Evaluation between ultrahigh pressure liquid chromatography and high-performance liquid chromatography analytical methods for characterizing natural dyestuffs.

    Science.gov (United States)

    Serrano, Ana; van Bommel, Maarten; Hallett, Jessica

    2013-11-29

    An evaluation was undertaken of ultrahigh pressure liquid chromatography (UHPLC) in comparison to high-performance liquid chromatography (HPLC) for characterizing natural dyes in cultural heritage objects. A new UHPLC method was optimized by testing several analytical parameters adapted from prior UHPLC studies developed in diverse fields of research. Different gradient elution programs were tested on seven UHPLC columns with different dimensions and stationary phase compositions by applying several mobile phases, flow rates, temperatures, and runtimes. The UHPLC method successfully provided more improved data than that achieved by the HPLC method. Indeed, even though carminic acid has shown circa 146% higher resolution with HPLC, UHPLC resulted in an increase of 41-61% resolution and a decrease of 91-422% limit of detection, depending on the dye compound. The optimized method was subsequently assigned to analyse 59 natural reference materials, in which 85 different components were ascribed with different physicochemical properties, in order to create a spectral database for future characterization of dyes in cultural heritage objects. The majority of these reference samples could be successfully distinguished with one single method through the examination of these compounds' retention times and their spectra acquired with a photodiode array detector. These results demonstrate that UHPLC analyses are extremely valuable for the acquisition of more precise chromatographic information concerning natural dyes with complex mixtures of different and/or closely related physicochemical properties, essential for distinguishing similar species of plants and animals used to colour cultural heritage objects.

  9. Ionic liquids for improving the extraction of NSAIDs in water samples using dispersive liquid-liquid microextraction by high performance liquid chromatography-diode array-fluorescence detection.

    Science.gov (United States)

    Toledo-Neira, Carla; Álvarez-Lueje, Alejandro

    2015-03-01

    A rapid, sensitive and efficient analytical method based on the use of ionic liquids for determination of non-steroidal anti-inflammatory drugs (NSAIDs) in water samples was developed. High-performance liquid chromatography equipped with a diode array and fluorescence detector was used for quantification of ketoprofen, ibuprofen and diclofenac in tap and river water samples. This new method relies on the use of two ionic liquids with multiple functionalities: one functions as an extraction solvent (1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF6]), and the other changes the polarity in the aqueous medium (1-butyl-3-methylimidazolium tetrafluoroborate, ([BMIM][BF4]). Factors such as the type and volume of the ILs and dispersive solvent, sample volume, and centrifugation time were investigated and optimized. The optimized method exhibited good precision, with relative standard deviation values between 2% and 3%, for the three NSAIDs. Limits of detection achieved for all of the analytes were between 17 and 95 ng mL(-1), and the recoveries ranged from 89% to 103%. Furthermore, the enrichment factors ranged from 49 to 57. The proposed method was successfully applied to the analysis of NSAIDs in tap and river water samples.

  10. Ultrasound-assisted dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-fluorescence detection for sensitive determination of biogenic amines in rice wine samples.

    Science.gov (United States)

    Huang, Ke-Jing; Wei, Cai-Yun; Liu, Wei-Li; Xie, Wan-Zhen; Zhang, Jun-Feng; Wang, Wei

    2009-09-18

    Ultrasound-assisted dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-fluorescence detection was used for the extraction and determination of three biogenic amines including octopamine, tyramine and phenethylamine in rice wine samples. Fluorescence probe 2,6-dimethyl-4-quinolinecarboxylic acid N-hydroxysuccinimide ester was applied for derivatization of biogenic amines. Acetonitrile and 1-octanol were used as disperser solvent and extraction solvent, respectively. Extraction conditions including the type of extraction solvent, the volume of extraction solvent, ultrasonication time and centrifuging time were optimized. After extraction and centrifuging, analyte was injected rapidly into high-performance liquid chromatography and then detected with fluorescence. The calibration graph of the proposed method was linear in the range of 5-500 microg mL(-1) (octopamine and tyramine) and 0.025-2.5 microg mL(-1) (phenethylamine). The relative standard deviations were 2.4-3.2% (n=6) and the limits of detection were in the range of 0.02-5 ng mL(-1). The method was applied to analyze the rice wine samples and spiked recoveries in the range of 95.42-104.56% were obtained. The results showed that ultrasound-assisted dispersive liquid-liquid microextraction was a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of biogenic amines.

  11. Theoretical and experimental comparison of one dimensional versus on-line comprehensive two dimensional liquid chromatography for optimized sub-hour separations of complex peptide samples.

    Science.gov (United States)

    Sarrut, Morgan; Rouvière, Florent; Heinisch, Sabine

    2017-05-19

    This study was devoted to the search for conditions leading to highly efficient sub-hour separations of complex peptide samples with the objective of coupling to mass spectrometry. In this context, conditions for one dimensional reversed phase liquid chromatography (1D-RPLC) were optimized on the basis of a kinetic approach while conditions for on-line comprehensive two-dimensional liquid chromatography using reversed phase in both dimensions (on-line RPLCxRPLC) were optimized on the basis of a Pareto-optimal approach. Maximizing the peak capacity while minimizing the dilution factor for different analysis times (down to 5min) were the two objectives under consideration. For gradient times between 5 and 60min, 15cm was found to be the best column length in RPLC with sub-2μm particles under 800bar as system pressure. In RPLCxRPLC, for less than one hour as first dimension gradient time, the sampling rate was found to be a key parameter in addition to conventional parameters including column dimension, particle size, flow-rate and gradient conditions in both dimensions. It was shown that the optimum sampling rate was as low as one fraction per peak for very short gradient times (i.e. below 10min). The quality descriptors obtained under optimized RPLCxRPLC conditions were compared to those obtained under optimized RPLC conditions. Our experimental results for peptides, obtained with state of the art instrumentation, showed that RPLCxRPLC could outperform 1D-RPLC for gradient times longer than 5min. In 60min, the same peak intensity (same dilution) was observed with both techniques but with a 3-fold lower injected amount in RPLCxRPLC. A significant increase of the signal-to-noise ratio mainly due to a strong noise reduction was observed in RPLCxRPLC-MS compared to the one in 1D-RPLC-MS making RPLCxRPLC-MS a promising technique for peptide identification in complex matrices. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Characterisation of dense non-aqueous phase liquids of coal tar using comprehensive two-dimensional gas chromatography coupled with time of flight mass spectrometry.

    Science.gov (United States)

    Gauchotte-Lindsay, Caroline; McGregor, Laura; Richards, Phil; Kerr, Stephanie; Glenn, Aliyssa; Thomas, Russell; Kalin, Robert

    2013-04-01

    Comprehensive two-dimensional gas chromatography (GCxGC) is a recently developed analytical technique in which two capillary columns with different stationary phases are placed in series enabling planar resolution of the analytes. The resolution power of GCxGC is one order of magnitude higher than that of one dimension gas chromatography. Because of its high resolution capacity, the use of GCxGC for complex environmental samples such as crude oils, petroleum derivatives and polychlorinated biphenyls mixtures has rapidly grown in recent years. We developed a one-step method for the forensic analysis of coal tar dense non-aqueous phase liquids (DNAPLs) from former manufactured gas plant (FMGP) sites. Coal tar is the by-product of the gasification of coal for heating and lighting and it is composed of thousands of organic and inorganic compounds. Before the boom of natural gases and oils, most towns and cities had one or several manufactured gas plants that have, in many cases, left a devastating environmental print due to coal tar contamination. The fate of coal tar DNAPLs, which can persist in the environment for more than a hundred years, is therefore of crucial interest. The presented analytical method consists of a unique clean-up/ extraction stage by pressurized liquid extraction and a single analysis of its organic chemical composition using GCxGC coupled with time of flight mass spectrometry (TOFMS). The chemical fingerprinting is further improved by derivatisation by N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) of the tar compounds containing -OH functions such as alcohols and carboxylic acids. We present here how, using the logical order of elution in GCxGC-TOFMS system, 1) the identification of never before observed -OH containing compounds is possible and 2) the isomeric selectivity of an oxidation reaction on a DNAPL sample can be revealed. Using samples collected at various FMGP sites, we demonstrate how this GCxGC method enables the simultaneous

  13. Two-dimensional calculus

    CERN Document Server

    Osserman, Robert

    2011-01-01

    The basic component of several-variable calculus, two-dimensional calculus is vital to mastery of the broader field. This extensive treatment of the subject offers the advantage of a thorough integration of linear algebra and materials, which aids readers in the development of geometric intuition. An introductory chapter presents background information on vectors in the plane, plane curves, and functions of two variables. Subsequent chapters address differentiation, transformations, and integration. Each chapter concludes with problem sets, and answers to selected exercises appear at the end o

  14. Two dimensional vernier

    Science.gov (United States)

    Juday, Richard D. (Inventor)

    1992-01-01

    A two-dimensional vernier scale is disclosed utilizing a cartesian grid on one plate member with a polar grid on an overlying transparent plate member. The polar grid has multiple concentric circles at a fractional spacing of the spacing of the cartesian grid lines. By locating the center of the polar grid on a location on the cartesian grid, interpolation can be made of both the X and Y fractional relationship to the cartesian grid by noting which circles coincide with a cartesian grid line for the X and Y direction.

  15. Development of the fingerprints for the quality evaluation of Viscum coloratum by high performance liquid chromatograp%Development of the fingerprints for the quality evaluation of Viscum coloratum by high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    Yun-Li Zhao; Rong-Hua Fan; Hong-Xia Yuan; Miao Yu; Kai-Shun Bi; Zhi-Guo Yu

    2011-01-01

    A high-performance liquid chromatography coupled ultraviolet (HPLC-UV) method was developed for a chemical fingerprint analysis of Viscum coloratura. Eighteen peaks were selected as the common peaks and Homoeriodictyol-7-O-β-D-apiosiyl-(1→2)-β-D-glucoside

  16. Speciation of arsenic using chelation solvent extraction and high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Cathum, Shamil J.; Obenauf, Alison; Punt, Monique [SAIC Canada, Ottawa, Ontario (Canada); Brown, Carl E. [Emergencies Engineering Technology Office, Environmental Technology Centre, Environment Canada, Ottawa, Ontario (Canada)

    2007-02-15

    Research interest in speciation of arsenic stems from its species dependent behavior in the environment and in living organisms. The complexity of the matrix to be analyzed and low concentrations of target arsenic species that may be labile or difficult to chromatogram, indicate that a suitable pre-treatment methodology is required. This study investigated the usefulness of chelation solvent extraction - high performance liquid chromatography (CSE-HPLC) for the speciation of arsenic in water. It involved reacting arsenic with the chelant known for its affinity towards arsenic, followed by extraction, separation, and identification of the arsenic-chelant-arsenic complex. Arsenic species having different physicochemical properties were investigated. Species, such as, As{sub 2}O{sub 3}, As{sub 3}O{sub 5}, KH{sub 2}AsO{sub 4}, Na{sub 2}HAsO{sub 4}, and NaAsO{sub 2}were detected as a group of closely eluted peaks with different retention times and spectral properties, whereas, the organic arsenic species CH {sub 3}Na {sub 2}AsO {sub 3}, o-arsanilic acid, roxarson and triphenyl arsine separated quite well on the EnviroseP-CM HPLC column. Key method parameters, such as, type of HPLC column, composition of mobile phase and organic solvents affecting peak resolution and sensitivity were optimized. Real environmental matrices contaminated with arsenic were analyzed under varying wavelengths ({lambda}{sub max} = 190, 210, 220, 234, 244, and 282 nm), with good precision. Different arsenic species were detected in these samples with excellent background and signal-to-noise ratios demonstrating the robustness of the method. The detection limit, reproducibility, selectivity, accuracy, and dynamic range of the calibration curves were evaluated. (Abstract Copyright [2007], Wiley Periodicals, Inc.)

  17. Estimation of loxoprofen sodium dihydrate in tablets by reverse phase high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    R. Nanthakumar

    2016-09-01

    Full Text Available A simple and rapid reverse phase high performance liquid chromatographic (RP-HPLC method has been developed and validated for the estimation of loxoprofen sodium dihydrate (LSD in tablets. An isocratic HPLC analysis was performed on Phenomenex, Luna C18(2 (250 × 4.6 mm, 5μ column. The compound was separated with the mixture of 0.4% orthophosphoric acid and acetonitrile in the ratio of 45:55 (v/v as a mobile phase at a flow rate of 1.0 mL/min. UV detection was performed at 210 nm. Run time per sample was 8 min with the retention time of 4.9 min. The system suitability parameters, such as theoretical plate count, tailing and% RSD between six standard injections were within the limits. The method was validated according to ICH guidelines. The method was validated for specificity, precision, linearity, stability of sample solution, intermediate precision, robustness and accuracy. The stability of the sample solution was checked for 24 h at one hour intervals. The results show that the sample solution is stable for at least 24 h. Calibration plots were linear over the concentration range of 10–90 μg/mL as indicated by the correlation coefficient of 0.9992. The% RSD was 0.115 and 1.288 for system precision and method precision, respectively. The % RSD values for intermediate precision studies were less than 2%. The robustness of the method was evaluated by deliberately altering the chromatographic conditions and the results were adhered with the limits. The high recovery and low relative standard deviation confirm the suitability of the method for the estimation of loxoprofen sodium dihydrate in tablets.

  18. Pharmacokinetic study of mangiferin in rat plasma and retina using high-performance liquid chromatography

    Science.gov (United States)

    Hou, Yunlong; Fan, Shengjun; Gu, Yuanqin; Yu, Xuhui; Li, Baoxin

    2010-01-01

    Purpose Although the naturally occurring antioxidant mangiferin has been widely used, it is not yet known whether it can cross the blood-retina barrier (BRB) and enter the eye. The purpose of this experiment was to investigate the ability of mangiferin to pass the blood-retina barrier. Methods Sprague–Dawley rats were used for biologic fluid sampling after intravenous administration of mangiferin at doses of 10, 25, and 50 mg/kg. Blood and retina samples were collected at different time points post-dose. High-performance liquid chromatography (HPLC) separation was conducted on a COSMOSIL 5C18—MS—II column (4.6 mm×250 mm, 5 μm) with a flow rate of 1.0 ml/min using a mobile phase comprised of methanol −2% glacial acetic acid (40:60 v:v). Results The HPLC method has proven suitable to determine the presence of mangiferin in the eye. The plasma concentration of mangiferin was dose dependent. Pharmacokinetic parameters of mangiferin in plasma after intravenous administration were fitted to the two-compartment model with the first-order elimination and first-order transfer between central and peripheral compartments. The concentration of mangiferin in the retina goes with that in the blood. Mangiferin concentrations in the retina reached 5.69±1.48 μg/ml 0.5 h after intravenous administration (50 mg/kg) and then dropped gradually to 0.30±0.02 μg/ml 5.0 h later. The eye–to-plasma concentration ratio was 2.80%. Conclusions Mangiferin can pass the blood-retina barrier after a single intravenous administration and may be a potential natural antioxidant in treating eye diseases. PMID:20806037

  19. DNA-based diagnosis of isolated sulfite oxidase deficiency by denaturing high-performance liquid chromatography.

    Science.gov (United States)

    Lam, Ching-Wan; Li, Chi-Keung; Lai, Chi-Kong; Tong, Sui-Fan; Chan, Kwok-Yin; Ng, Grace Sui-Fun; Yuen, Yuet-Ping; Cheng, Anna Wai-Fun; Chan, Yan-Wo

    2002-01-01

    Isolated sulfite oxidase deficiency is a rare autosomal recessive disease, characterized by severe neurological abnormalities, seizures, mental retardation, and dislocation of the ocular lenses, that often leads to death in infancy. There is a special demand for prenatal diagnosis, since no effective treatment is available for isolated sulfite oxidase deficiency. Until now, the cDNA sequence of the sulfite oxidase (SUOX) gene has been available, but the genomic sequence of the SUOX gene has not been published. In this study, we have performed a DNA-based diagnosis of isolated sulfite oxidase deficiency in a Chinese patient. To do so, we designed oligonucleotide primers for amplification of the predicted exons and intron-exon boundaries of the SUOX gene obtained from the completed draft version of the human genome. Using overlapping PCR products, we confirmed the flanking intronic sequences of the coding exons and that the entire 466-residue mature peptide is encoded by the last exon of the gene. We then performed mutation detection using denaturing high-performance liquid chromatography (DHPLC). The DHPLC chromatogram of exon 2b showed the presence of heteroduplex peaks only after mixing of the mutant DNA with the wild-type DNA, indicating the presence of a homozygous mutation. Direct DNA sequencing showed a homozygous base substitution at codon 160, changing the codon from CGG to CAG, which changes the amino acid from arginine to glutamine, i.e., R160Q. The DNA-based diagnosis of isolated sulfite oxidase deficiency will enable us to make an accurate determination of carrier status and to perform prenatal diagnosis of this disease. The availability of the genomic sequences of human genes from the completed draft human genome sequence will simplify the development of molecular genetic diagnoses of human diseases from peripheral blood DNA.

  20. Analysis of Some Pesticide Residues in Cauliflower by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Sheheli Islam

    2009-01-01

    Full Text Available Problem statement: Increased use of chemicals on vegetables started gaining momentum and continued its up-trend in Bangladesh. Wide spread use of pesticides in agriculture concern of residue accumulation, which may remain in food and agricultural environment causing concern of human health and risking ecological balance. Attempt made to ensure that their applications were correct and safe and result in no residues in food beyond codex developed maximum residue limits. Approach: This study reported a method based on High Performance Liquid Chromatography (HPLC for determination of pesticide residues used in Cauliflower. Cauliflower sprayed with, 4 different pesticides (diazinon, malathion, chlorpyrifos and cypermethrin at recommended dose and double of recommended dose were analyzed for their residual contents. Samples were collected at same day after application of pesticide. Commercial samples of cauliflowers were collected from different markets of Dhaka city. Reversed-phase HPLC system with UV detection was used for the separation, identification and quantification of all these analytes using acetonitrile-water (70:30, v/v as mobile phase. Results: Limit of detection of 0.02 mg kg-1 was obtained. Calibration curves that constructed for the analytes spiked into samples followed linear relationships with good correlation coefficients (R2>0.990. In the analysis, from vegetables treated with diazinon and chlorpyrifos at recommended and double of recommended doses, residual amounts above respective MRL values were found. Conclusion: Method used permitted the determination of these pesticides in cauliflower at concentration level demanded by current legislation. Attention paid on excess use or abuse of pesticides by judicious application for safety of public health in Bangladesh. Additional data to monitor residues in food and to fill gaps in current knowledge would be helpful in assessing human exposure risks from ingestion of contaminated

  1. Simultaneous determination of cyclodol and diprazin by thin layer chromatography and high performance liquid chromatography.

    Science.gov (United States)

    Makharadze, R; Adeishvili, L; Chelidze, T; Imnadze, N; Nizharadze, N

    2009-11-01

    Ciklodol (trihexyphenidil)--the central and peripheral m-cholinoblocker is currently used with other antipsychotic drugs such as phenotiazines and tricycle antidepressants. For the purpose of simultaneous determination of ciklodol and diprazine, were selected two methods of analysis: Thin Layer Chromatography (TLC) and High Performance Liquid Chromatography (HPLC). During development of TLC method was studied the 10 visualizing system and 24 mobile systems. For individual or simultaneous determination of ciklodol and diprazine were recommended the following solvents' systems: 1. Toluene-acetone-ethanole-25%NH(4)OH (45:45: 7.5:2.5), 2. Hexane-ethyl acetate (15:5), 3. Chloroform-heptene-25%NH(4)OH (16:3:3), 4. Ethylacetate-hexane (10:10), 5. Acetonitrile-metanol (10:10) and 6.Heptene-chloroform-ethanol-25% NH(4)OH (5:10:3:1). As visualizing systems were chosen: Iodine vapors, blacklight (UV254) and reagent of FNP. Reagent of FNP gives colored spot just with diprazine and it is also could be used for separation of both objects in simultaneous analysis. Developed HPLC method of simultaneous determination of ciklodol and diprazine: like mobile phase is recommended: Acetonitril- 0.05M KH(2)PO4 (55:45) (v/v) +H(3)PO(4) (pH3.5), column EC250 x 4.6mm, with solid phase Nucleosil, flow rate 1ml/min, sample volume 40 microl. In given conditions, the retention time of ciklodol is 6.005min and diprazine 7.227min. Developed method of simultaneous determination and separation of ciklodol and diprazine in respective mixtures could be successfully applied as in the pharmaceutical, as well in the chemical-toxicological laboratories.

  2. Advanced use of high-performance liquid chromatography for synthesis of controlled metal clusters.

    Science.gov (United States)

    Niihori, Yoshiki; Matsuzaki, Miku; Uchida, Chihiro; Negishi, Yuichi

    2014-07-21

    Because the synthesis of metal clusters with multiple ligand types results in a distribution of ligands, high-resolution separation of each unique cluster from the mixture is required for precise control of the ligand composition. Reverse-phase high-performance liquid chromatography combined with appropriate transitioning of the mobile phase composition is an extremely effective means of separating ligand combinations when working with metal clusters protected by two different types of thiolates. We report herein advanced use of this method. The studies involving Au₂₄Pd(SR₁)₁₈-x(SR₂)x and Au₂₄Pd(SR₁)₁₈-x(SeR₂)x (SR₁, SR₂ = thiolate, SeR₂ = selenolate) revealed the following. (1) In general, an increase in the difference between the polarities of the functional groups incorporated in the two types of ligands improves the separation resolution. A suitable ligand combination for separation can be predicted from the retention times of Au₂₄Pd(SR₁)₁₈ and Au₂₄Pd(SR₂)₁₈, which cause the terminal peaks in a series of peaks. (2) The use of a step-gradient program during the mobile phase substitution results in improved resolution compared to that achievable with the linear gradients applied in prior work. (3) This technique is also useful for the evaluation of the chemical compositions of metal clusters protected by two different types of ligands with similar molecular weights. These findings will provide clear design guidelines for the functionalization of metal clusters via control of the ligand composition, and will also improve our understanding of the high-resolution isolation of metal clusters.

  3. Quantification of free formaldehyde in carrageenan and processed Eucheuma seaweed using high-performance liquid chromatography.

    Science.gov (United States)

    Hornshøj, Bettina Høj; Kobbelgaard, Sara; Blakemore, William R; Stapelfeldt, Henrik; Bixler, Harris J; Klinger, Markus

    2015-01-01

    In 2010 the European Commission placed a limit on the amount of free formaldehyde in carrageenan and processed Eucheuma seaweed (PES) of 5 mg kg(-1). Formaldehyde is not used in carrageenan and PES processing and accordingly one would not expect free formaldehyde to be present in carrageenan and PES. However, surprisingly high levels up to 10 mg kg(-1) have been found using the generally accepted AOAC and Hach tests. These findings are, per proposed reaction pathways, likely due to the formation of formaldehyde when sulphated galactose, the backbone of carrageenan, is hydrolysed with the strong acid used in these conventional tests. In order to minimise the risk of false-positives, which may lead to regulatory non-compliance, a new high-performance liquid chromatography (HPLC) method has been developed. Initially, carrageenan or PES is extracted with 2-propanol and subsequently reacted with 2,4-dinitrophenylhydrazine (DNPH) to form the chromophore formaldehyde-DNPH, which is finally quantified by reversed-phase HPLC with ultraviolet light detection at 355 nm. This method has been found to have a limit of detection of 0.05 mg kg(-1) and a limit of quantification of 0.2 mg kg(-1). Recoveries from samples spiked with known quantities of formaldehyde were 95-107%. Using this more specific technique, 20 samples of carrageenan and PES were tested for formaldehyde. Only one sample had a detectable content of formaldehyde (0.40 mg kg(-1)), thus demonstrating that the formaldehyde content of commercial carrageenan and PES products are well below the European Commission maximum limit of 5 mg kg(-1).

  4. Robust naphthyl methacrylate monolithic column for high performance liquid chromatography of a wide range of solutes.

    Science.gov (United States)

    Jonnada, Murthy; El Rassi, Ziad

    2015-08-28

    An organic monolithic column based on the co-polymerization of 2-naphthyl methacrylate (NAPM) as the functional monomer and trimethylolpropane trimethacrylate (TRIM) as the crosslinker was introduced for high performance reversed-phase liquid chromatography (RPC). The co-polymerization was performed in situ in a stainless steel column of 4.6mm i.d. in the presence of a ternary porogen consisting of 1-dodecanol and cyclohexanol. This monolithic column (referred to as naphthyl methacrylate monolithic column or NMM column) showed high mechanical stability at relatively high mobile phase flow velocity indicating that the column has excellent hydrodynamic characteristics. To characterize the NMM column, different probe molecules including alkyl benzenes, and aniline, benzene, toluene and phenol derivatives were chromatographed on the column and the results in terms of k, selectivity and plate counts were compared to those obtained on an octadecyl silica (ODS) column in order to assess the presence of π-π and hydrophobic interactions on the NMM column under otherwise the same elution conditions. The NMM column offered additional π-π interactions with aromatic molecules in addition to hydrophobic interactions under RPC elution conditions. Run-to-run and column-to-column reproducibility of solute k values were evaluated, and percent relative standard deviation of column using shallow (30min at 1.0mL/min), steep (10min at 1.0mL/min) and ultra steep (1min at 3.0mL/min) linear gradient elution at increasing ACN concentration in the mobile phase using a 10cm×4.6mm i.d. column in case of shallow and steep linear gradients and a 3cm×4.6mm i.d. column for ultra steep linear gradient.

  5. [Rapid determination of propranolol enantiomers in rat plasma by column-switching-high performance liquid chromatography].

    Science.gov (United States)

    Wu, Xiaoyu; Wang, Rong; Xie, Hua; Wang, Jianfeng; Jia, Zhengping; Zhang, Qiang; Wang, Xianhua

    2011-12-01

    A high performance liquid chromatographic (HPLC) method with column-switching was developed and validated for rapid determination of two propranolol enantiomers in rat plasma. The column of restricted-access media was used as a pre-treatment column and a Chiralcel OD-RH was used as analytical column. The plasma samples were injected directly into the pretreatment column to remove plasma protein and endogenous constituents as well as to retent the propranolol enantiomers in the column using the mobile phase of borate buffer (pH 8.5)-methanol (95:5, v/v) at the flow rate of 1.0 mL/min. Then the propranolol enantiomers were transferred to the Chiralcel OD-RH column using the mobile phase of isopropanol-ethanol-0.2 mmol/L borate buffer (pH 8.5) (30: 30: 40, v/v/v) at a flow rate of 0.8 mL/min by column-switching technology. The column-switching time was 3.0 min, the used wavelength was 293 nm and the column temperature was set at 25 degrees C. The calibration curve showed excellent linear relationship (r = 0.999 5) in the concentration range from 25 mg/L to 500 mg/L for propranolol enantiomers in plasma. The intra-day and inter-day assay precisions and accuracies were well and the relative standard deviations (RSDs) were less than 5%. The average recoveries (n = 6) of the two enantiomers at 3 spiked levels were from 97.89% to 101.56%. All the values of the method validation were within the generally accepted criteria for biological sample analysis. The results show that the method is convenient, quick, sensitive and accurate. The method was successfully applied in the determination of propranolol enantiomers in rat blood pharmacokinetics study.

  6. Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns.

    Science.gov (United States)

    Jones, Andrew; Pravadali-Cekic, Sercan; Hua, Stanley; Kocic, Danijela; Camenzuli, Michelle; Dennis, Gary; Shalliker, Andrew

    2016-04-26

    A protocol for the use of reaction flow high performance liquid chromatography columns for methods employing post column derivatization (PCD) is presented. A major difficulty in adapting PCD to modern HPLC systems and columns is the need for large volume reaction coils that enable reagent mixing and then the derivatization reaction to take place. This large post column dead volume leads to band broadening, which results in a loss of observed separation efficiency and indeed detection in sensitivity. In reaction flow post column derivatization (RF-PCD) the derivatization reagent(s) are pumped against the flow of mobile phase into either one or two of the outer ports of the reaction flow column where it is mixed with column effluent inside a frit housed within the column end fitting. This technique allows for more efficient mixing of the column effluent and derivatization reagent(s) meaning that the volume of the reaction loops can be minimized or even eliminated altogether. It has been found that RF-PCD methods perform better than conventional PCD methods in terms of observed separation efficiency and signal to noise ratio. A further advantage of RF-PCD techniques is the ability to monitor effluent coming from the central port in its underivatized state. RF-PCD has currently been trialed on a relatively small range of post column reactions, however, there is currently no reason to suggest that RF-PCD could not be adapted to any existing one or two component (as long as both reagents are added at the same time) post column derivatization reaction.

  7. Rayleigh light scattering detection of three α1-adrenoceptor antagonists coupled with high performance liquid chromatograph

    Science.gov (United States)

    Li, Ai Ping; Peng, Huanjun; Peng, Jing Dong; Zhou, Ming Qiong; Zhang, Jing

    2015-08-01

    Herein, a Rayleigh light-scattering (RLS) detection method combined with high performance liquid chromatograph (HPLC) without any post-column probe was developed for the separation and determination of three α1-adrenoceptor antagonists. The quantitative analysis is benefiting from RLS signal enhancement upon addition of methanol which induced molecular aggregation to form an hydrophobic interface between aggregates and water that produce a sort of superficial enhanced scattering effect. A good chromatographic separation among the compounds was achieved using a Gemini 5u C18 reversed phase column (250 mm × 4.6 mm; 4 μm) with a mobile phase consisting of methanol and ammonium acetate-formic acid buffer solution (25 mM; pH = 3.0) at the flow rate of 0.7 mL min-1. The RLS signal was monitored at λex = λem = 354 nm. A limit of detection (LOD) of 0.065-0.70 μg L-1 was reached and a linear range was found between peak height and concentration in the range of 0.75-15 μg L-1 for doxazosin mesylate (DOX), 0.075-3.0 μg L-1 for prazosin hydrochloride (PRH), and 0.25-5 μg L-1 for terazosin hydrochloride (TEH), with linear regression coefficients all above 0.999. Recoveries from spiked urine samples were 88.4-99.0% which is within acceptable limits. The proposed method is convenient, reliable and sensitive which has been used successfully in human urine samples.

  8. [Determination of aflatoxins in cashew by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Bi, Ruifeng; Fan, Zhixian; Fu, Meng

    2011-12-01

    A method for the determination of four aflatoxins in cashew using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. The sample was extracted with methanol-water (8: 2, v/v) solution, followed by a cleanup procedure with Florisil column. The target compounds were eluted using 5 mL acetone-water-formic acid (96: 3.5:0.5, v/v/v) solution. The eluate was dried under N2, then dissolved in 1 mL methanol. Four aflatoxins were separated in MG C18 column (100 mm x 3.0 mm, 3 microm) adopting a gradient program within 15 min. A triple quadrupole mass spectrometry equipped with an electrospray ionization source operated in the positive ion mode was used to detect the aflatoxins. The good correlation coefficients (r2 > 0.997) of the four aflatoxins were obtained within their respective linear ranges. The limits of detection (S/N = 3) were between 0.009 microg/kg and 0.04 microg/kg, and the limits of quantification (S/N = 10) were between 0.03 microg/kg and 0.12 microg/kg. The recoveries were in a range of 63.0% -78.5% with the relative standard deviations (RSDs) varied from 2.8% to 9.1%. The validation results meet the requirements of trace assay. Matrix effects were estimated and the signal suppression/enhancement ranged from 88.8% to 99.4%. The results indicate that the developed method is simple, fast, accurate, and can be applied for the determination of fours aflatoxins in cashew.

  9. Chiral stationary phases based on chitosan bis(methylphenylcarbamate)-(isobutyrylamide) for high-performance liquid chromatography.

    Science.gov (United States)

    Tang, Sheng; Bin, Qin; Chen, Wei; Bai, Zheng-Wu; Huang, Shao-Hua

    2016-04-01

    A series of chitosan bis(methylphenylcarbamate)-(isobutyrylamide) derivatives were synthesized by carbamylating chitosan isobutyrylamide with different methylphenyl isocyanates. Then the prepared chitosan derivatives were coated onto 3-aminopropyl silica particles, resulting in a series of new chiral stationary phases (CSPs) for high-performance liquid chromatography. It was observed that the chiral recognition abilities of these coated-type CSPs depended very much on the substituents on the phenyl moieties of the chitosan derivatives, the eluent composition, as well as the structure of racemates. As a typical example, the eluent tolerance of the prepared CSP with the best enantioseparation ability was investigated in detail, and the results revealed that the CSP exhibited extraordinary solvent tolerance and could still work without significant loss in enantioseparation capability after being flushed with chloroform (100%), ethyl acetate (100%) and even THF/n-hexane (70/30, v/v), while the traditional coated-type CSPs based on the cellulose and amylose derivatives, such as cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) and amylose tris(3,5-dimethylphenylcarbamate) (ADMPC), might be dissolved or highly swollen in these eluents. Therefore, the application of the resultant CSPs could address the problem of the dissolution and high swelling of traditional coated-type CSPs in some unusual eluents, broadening the possibility of eluent choice. In addition, a comparison of the prepared CSPs with the well known CDMPC- and ADMPC- based CSPs concerning the chiral recognition ability was also made. Separation performances achieved on the as-prepared CSPs in different eluents were found to be even superior to CDMPC- and ADMPC-based CSPs for the tested chiral compounds. In summary, we could safely draw the conclusion that the CSPs derived from chitosan isobutyrylamide derivatives were capable of excellent chiral recognition ability, and meanwhile possessed satisfactory

  10. Enantiomeric Separations of Pyriproxyfen and its Six Chiral Metabolites by High-Performance Liquid Chromatography.

    Science.gov (United States)

    Zhang, Chuntao; Liu, Hui; Liu, Donghui; Wang, Liying; Gao, Jing; Zhou, Zhiqiang; Wang, Peng

    2016-03-01

    Pyriproxyfen is a chiral insecticide, and over 10 metabolites have been identified in the environment. In this work the separations of the enantiomers of pyriproxyfen and its six chiral metabolites were studied by high-performance liquid chromatography (HPLC). Both normal phase and reverse phase were applied using the chiral columns Chiralpak IA, Chiralpak IB, Chiralpak IC, Chiralcel OD, Chiralcel OD-RH, Chiralpak AY-H, Chiralpak AD-H, Chiracel OJ-H, (R,R)-Whelk-O 1, and Lux Cellulose-3. The effects of the chromatographic parameters such as mobile phase composition and temperature on the separations were investigated and the enantiomers were identified with an optical rotation detector. The enantiomers of these targets could obtain complete separations (resolution factor Rs > 1.5) on Chiralpak IA, Chiralpak IB, Chiralcel OD, Chiralpak AY-H, or Chiracel OJ-H under normal conditions. Chiralcel OJ-H showed the best chiral separation results with n-hexane as mobile phase and isopropanol (IPA) as modifier. The simultaneous enantiomeric separation of pyriproxyfen and four chiral metabolites was achieved on Chiralcel OJ-H under optimized condition: n-hexane/isopropanol = 80/20, 15°C, flow rate of 0.8 ml/min, and UV detection at 230 nm. The enantiomers of pyriproxyfen and the metabolites , , and obtained complete separations on Chiralpak IA, Chiralpak IC, and Lux Cellulose-3 under reverse phase using acetonitrile/water as the mobile phase. The retention factors (k) and selectivity factors (α) decreased with increasing temperature, and the separations were better under low temperature in most cases. The work is of significance for the investigation of the environmental behaviors of pyriproxyfen on an enantiomeric level.

  11. Pharmacokinetics of mitomycin C in dogs: application of a high-performance liquid chromatographic assay.

    Science.gov (United States)

    Barbhaiya, R H; Papp, E A; Van Harken, D R; Smyth, R D

    1984-09-01

    A normal-phase high-performance liquid chromatographic (HPLC) assay was developed for the determination of mitomycin C in plasma and urine. The method involves extraction of mitomycin C from plasma or urine into ethyl acetate-2-propanol-chloroform (70:15:15) with UV detection at 365 nm. Quantitation was performed with an internal standard (porfiromycin) by the peak height ratio method. Excellent correlation was obtained between the HPLC assay and the established microbiological cup-plate bioassay. The pharmacokinetics of mitomycin C were investigated in beagle dogs following a 1-mg/kg iv (22-mg/m2) bolus dose. The plasma mitomycin C concentration versus time data were analyzed by using an open three-compartment model. The average volume of distribution was 1.90 L or 17% of body weight for the central compartment and 7.7 L or 68% of body weight for the terminal elimination phase. The volumes of distribution at steady state, calculated by model-dependent and -independent methods, compared very well with each other and were 6.5 L or 58% of body weight. Total body clearance averaged 112 mL/min, and the mean terminal plasma half-life was 53 min. The 0-24-h urinary excretion of intact mitomycin C accounted for 19% of the dose. The terminal half-life and percent urinary recovery of mitomycin C in dogs is similar to that in humans. Based on these observations, the dog appears to be a good model for studying the disposition of mitomycin C.

  12. [Determination of phospholipids in bear bile by isocratic high performance liquid chromatography].

    Science.gov (United States)

    Lu, X Q; Wang, Z H; Hong, X K; Sun, J J; Zhang, S W

    1999-11-01

    A high performance liquid chromatographic method for the determination of phosphatidylcholine (PC), phosphatidylethanolamine (PE) and phosphatidylinositol (PI) in the bear bile was established. The air-dried bile of bear was ground into powder and extracted continuously with V(chloroform):V(methanol) = 1:1 to a final dilution 25-fold the volume of the sample. The extract was washed by addition to it of 0.5 its volume of 0.58% aqueous NaCl. The resulting mixture separated into two phases. The lower phase was the total pure lipid extract and was diluted to the desired volume by addition of V(chloroform):V(methanol) = 1:1 mixture and then injected into the HPLC system. The conditions of HPLC were P-E silica column (150 mm x 4.6 mm i.d., 10 microns); V(acetonitrile):V(methanol) = 76:24 mobile phase with a flow rate of 1.5 mL/min and UV detector at 205 nm. The linear regression equation was Y = 5,917X + 1,709(r = 0.9970) for PI, Y = 7,362.1X-6,608.2(r = 0.9949) for PE and Y = 2,457X-2,460.5(r = 0.9972) for PC. The linear range were 1.0-12.0 micrograms, 2.0-24.0 micrograms and 9.5-114.0 micrograms respectively, The relative standard deviation of peaks were 1.6%, 0.89% and 2.6% respectively. The average recovery of PC was 89.30% (RSD = 2.0%). The method enables a simple, rapid and reproducible quantification of PI, PE and PC.

  13. Determination of plasma lactic acid concentration and specific activity using high-performance liquid chromatography.

    Science.gov (United States)

    Bleiberg, B; Steinberg, J J; Katz, S D; Wexler, J; LeJemtel, T

    1991-08-23

    Assessment of lactate metabolism is of particular interest during exercise and in disease states such as diabetes, shock, and absorptive abnormalities of short-chain fatty acids by the colon. We describe an analytical method that introduces radio-active tracers and high-performance liquid chromatography (HPLC) to simultaneously analyze concentrations and specific activities (SAs) of plasma lactate. The HPLC conditions included separation on a reversed-phase column (octadecylsilane) and an isocratic buffer (30% acetonitrile in water). [3H]Acetate served as an internal standard. Lactate and acetate were extracted from plasma samples with diethyl ether following a pH adjustment to less than 1.0 and back-extracted into a hydrophilic phase with sodium carbonate (2 mM, pH greater than 10.0). Lactate is detected in the ultraviolet range (242 and 320 nm) by derivatization with alpha-bromoacetophenone. Control plasma samples were studied after an overnight fast for precision and analytical recovery. Calibration curves were linear in the range 0.18-6.0 mM (r = 0.92). The precision was 3% and the analytical recovery was 87%. The detection limit of the method was 36 pmol. Determination of lactate metabolism was performed in a patient with chronic congestive heart failure who was administered primed-continuous L-[U-14C]lactate (10 microCi bolus and 0.3 microCi/min continuously) during a 60-min rest period. Mean arterial lactate concentration and SA were 1.69 +/- 0.2 mM and 253.8 +/- 22 dpm/mumol, respectively. Systemic lactate turnover was 25.65 mumol/kg per min. Lactic acid systemic turnover, organ uptake and release rates can be accurately determined by isocratic HPLC.

  14. Simultaneous determination of multiple marker constituents in concentrated Gegen Tang granule by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Yip Yuekeung

    2007-06-01

    Full Text Available Abstract Background Concentrated Gegen Tang (GT granule is a widely available traditional Chinese medicinal product for the treatment of cold and flu. There was no reliable analytical method available for the quality assessment of GT granules. Methods An HPLC method with an Agilent Zorbax SB-Phenyl Stablebond column (250 × 4.6 mm, 5 μm was developed and validated. The mobile phase gradient was a mixture of 0.1% trifluoroacetic acid (TFA in acetonitrile (ACN and 0.1% TFA in water. The detection with a diode-array detector was set at 207, 230, 250 and 275 nm. Seven components, namely puerarin, daidzein, paeoniflorin, cinnamic acid, glycyrrhizin, ephedrine and pseudoephedrine were selected as marker compounds for the evaluation. Results The regression equations revealed good linear relationships (correlation coefficients: 0.9994–0.9998 between the peak areas and concentrations. The recovery was between 98.8% and 101.7% with good precision and accuracy. The quality of GT granule from four different manufacturers was evaluated with this newly developed method. Samples from four manufacturers showed similar profiles but contents of the detected markers varied significantly among manufacturers and batches. Conclusion A new method using high performance liquid chromatography (HPLC has been developed for simple and reliable quality control of commercial concentrated GT granules. Sensitivity was increased by multi-wavelength detection. The contents of selected marker components in GT granules varied significantly among manufacturers and batches, making it necessary to evaluate the quality of concentrated GT granules in the market.

  15. Simultaneous determination of three sesquiterpene lactones in Aucklandia lappa Decne by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Chang-Seob Seo

    2015-01-01

    Full Text Available Background: Aucklandia lappa Decne, a well known traditional herbal medicine, is used for the treatment of asthma, rheumatism, coughs, tuberculosis, and many other diseases. Objective: We performed simultaneous analysis of three sesquiterpene lactones, costunolide (1, dehydrocostus lactone (2, and alantolactone (3, obtained from a 70% methanol extract of A. lappa using high performance liquid chromatography–photodiode array (HPLC–PDA techniques. Materials and Methods: The compounds 1–3 were separated using a reversed phase SunFire™ C18 analytical column kept at 35°C by the isocratic elution with distilled water and acetonitrile as mobile phase. The flow rate was 1.0 mL/min, and the injection volume was 10 μL. Results: The established analytical method showed high linearity, with a correlation coefficient ≥0.9999. The limit of detection and the limit of quantification of compounds 1–3 were 0.06–0.13 μg/mL and 0.21–0.42 μg/mL, respectively. The recovery of the compounds 1–3 was 97.27–103.00%. The intra and inter day relative standard deviations were 0.09–0.97% and 0.09–1.06%, respectively. The amounts of the compounds 1–3 were 17.32, 28.26, and 0.01 mg/g, respectively. Conclusion: The established and validated HPLC–PDA method may be help for the quality control of herbal medicine, A. lappa.

  16. High performance liquid chromatography--atomic fluorescence spectrometric determination of arsenic species in beer samples

    Energy Technology Data Exchange (ETDEWEB)

    Melo Coelho, N.M.; Parrilla, Carmen; Cervera, M.L.; Pastor, A.; Guardia, M. de la

    2003-04-10

    A method has been developed for the direct determination of As(III), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and As(V) in beers by hydride generation--atomic fluorescence spectrometry after separation of arsenic species by high performance liquid chromatography. Compounds were separated by anion-exchange chromatography with isocratic elution using KH{sub 2}PO{sub 4}/K{sub 2}HPO{sub 4} as mobile phase with elution times of 1.67, 2.08, 6.52 and 10.72 min for As(III), DMA, MMA and As(V), respectively. Parameters affecting the hydride generation of all arsenic species were studied and the best conditions were established as a reaction coil of 150 cm, for a sample injected volume of 100 {mu}l, a 4.0% (m/v) solution of sodium tetrahydroborate and 2.0 mol l{sup -1} hydrochloric acid with flow rates of 2.7 and 1.7 ml min{sup -1}, respectively and a flow rate of 500 ml min{sup -1} for the argon carrier gas. Under the best experimental conditions, the detection limit was found to be 0.12, 0.20, 0.27 and 0.39 {mu}g l{sup -1} for As(III), DMA, MMA and As(V), respectively. The relative standard deviation for eight independent determinations varied from 3.9 till 8.9% for species considered at a concentration level of 10.0 {mu}g l{sup -1}. Recovery and comparative studies evidenced that the method is suitable for the accurate determination of arsenic species in water and beer samples.

  17. Ultra-high-performance liquid chromatography profiling method for chemical screening of proanthocyanidins in Czech hops.

    Science.gov (United States)

    Olšovská, J; Kameník, Z; Čejka, P; Jurková, M; Mikyška, A

    2013-11-15

    Hops represent an important natural source of bioactive polyphenols, particularly proanthocyanidins, which can contribute to prevention of several civilization diseases, owing to their antioxidant and radical scavenging activity. We have developed a high-throughput ultra-high-performance liquid chromatography time-of-flight mass spectrometry profiling method, which can be used for monitoring of bioactive proanthocyanidins in hops. The method was applied for analysis of hops of four Czech varieties (Saaz, Sladek, Preminat and Agnus) from the 2011 crop (9 localities, 11 samples) and the 2012 crop (24 localities, 40 samples). Hop samples were extracted by acetone and the analytes were separated on the Acquity UPLC BEH Shield RP18 column. Partial validation of the method revealed a satisfactory intra-day repeatability of the method for retention times (relative standard deviation within 1.39%) as well as areas under the peaks (within 9.89%). Experimental data were evaluated using principal component analysis and cluster analysis. Significant amounts of di-, tri- and tetramer proanthocyanidins consisting of (epi)catechin and (epi)gallocatechin were found in the hop samples. The dependence of the proantocyanidin composition on both the variety and the growing locality was observed. Specifically, the traditional Saaz variety contained more frequently oligomers formed by (epi)catechin units only, whereas the varieties Premiant and Agnus produced oligomers consisting of (epi)catechin as well as (epi)gallocatechin units. The relative abundance of proanthocyanidins in studied hop varieties from the two crops, 2011 and 2012, did correspond to each other. In the further perspective, the method may also be used for prediction of qualitative marks or authenticity verification of hops.

  18. Dynamic Behavior of Clobazam on High-Performance Liquid Chromatography Chiral Stationary Phases.

    Science.gov (United States)

    Sabia, Rocchina; De Martino, Michela; Cavazzini, Alberto; Villani, Claudio

    2016-01-01

    Clobazam, a 1,5-benzodiazepin-2,4-dione, is a chiral molecule because its ground state conformation features a nonplanar seven-membered ring lacking reflection symmetry elements. The two conformational enantiomers of clobazam interconvert at room temperature by a simple ring-flipping process. Variable temperature HPLC on the Pirkle type (R)-N-(3,5-dinitronenzoyl)phenylglycine and (R,R)-Whelk-O1 chiral stationary phases (CSPs) allowed us to separate for the first time the conformational enantiomers of clobazam and to observe peak coalescence-decoalescence phenomena due to concomitant separation and interconversion processes occurring on the same time scale. Clobazam showed temperature dependent dynamic high-performance liquid chromatography (HPLC) profiles with interconversion plateaus on the two CSPs indicative of on-column enantiomer interconversion. (enantiomerization) in the column temperature range between Tcol = 10°C and Tcol = 30°C, whereas on-column interconversion was absent at temperature close to or lower than Tcol = 5°C. Computer simulation of exchange-deformed HPLC profiles using a program based on the stochastic model yielded the apparent rate constants for the on-column enantiomerization and the corresponding free energy activation barriers. At Tcol = 20°C the averaged enantiomerization barriers, ΔG(‡), for clobazam were found in the range 21.08-21.53 kcal mol(-1) on the two CSPs. The experimental dynamic chromatograms and the corresponding interconversion barriers reported in this article are consistent with the literature data measured by DNMR at higher temperatures and in different solvents.

  19. Validation of stability indicating high performance liquid chromatographic method for estimation of Desloratadine in tablet formulation

    Directory of Open Access Journals (Sweden)

    R.B. Patel

    2017-02-01

    Full Text Available A simple, sensitive and specific stability indicating high performance liquid chromatographic (HPLC method for the estimation of Desloratadine was developed and validated. Desloratadine was separated and quantitated on Inertsil ODS-3 V column (250 mm length, 4.6 mm id, 5 μm particle size using a mixture of methanol–phosphate buffer of pH 7.0 (70:30 v/v as a mobile phase and at a flow rate of 1.0 mL/min. Quantification was achieved with an UV detector at 254 nm over the concentration range of 5–75 μg/mL. The applied HPLC method allowed the separation and quantification of Desloratadine with good linearity (r2 = 0.999 in the studied concentration range. Limit of detection and limit of quantification were found to be 1.28 μg/mL and 3.89 μg/mL, respectively. The method was validated as per the International Conference on Harmonization (ICH guidelines. Desloratadine stock solution was subjected to different stress conditions. The degraded product peaks were well resolved from the pure drug peak with significant difference in their retention time values. Stressed samples were assayed using developed HPLC method. Statistical analysis of the data showed that the method is precise, accurate, reproducible, and selective for the analysis of Desloratadine. The method was successfully applied to the estimation of Desloratadine in tablet dosage form.

  20. Chromatographic behavior of small organic compounds in low-temperature high-performance liquid chromatography using liquid carbon dioxide as the mobile phase.

    Science.gov (United States)

    Motono, Tomohiro; Nagai, Takashi; Kitagawa, Shinya; Ohtani, Hajime

    2015-07-01

    Low-temperature high-performance liquid chromatography, in which a loop injector, column, and detection cell were refrigerated at -35ºC, using liquid carbon dioxide as the mobile phase was developed. Small organic compounds (polyaromatic hydrocarbons, alkylbenzenes, and quinones) were separated by low-temperature high-performance liquid chromatography at temperatures from -35 to -5ºC. The combination of liquid carbon dioxide mobile phase with an octadecyl-silica (C18 ) column provided reversed phase mode separation, and a bare silica-gel column resulted in normal phase mode separation. In both the cases, nonlinear behavior at approximately -15ºC was found in the relationship between the temperature and the retention factors of the analytes (van't Hoff plots). In contrast to general trends in high-performance liquid chromatography, the decrease in temperature enhanced the separation efficiency of both the columns.